Sample records for tarjetas g-1 tld-100

  1. Robust determination of effective atomic numbers for electron interactions with TLD-100 and TLD-100H thermoluminescent dosimeters

    NASA Astrophysics Data System (ADS)

    Taylor, M. L.

    2011-04-01

    Lithium fluoride thermoluminescent dosimeters (TLD) are the most commonly implemented for clinical dosimetry. The small physical magnitude of TLDs makes them attractive for applications such as small field measurement, in vivo dosimetry and measurement of out-of-field doses to critical structures. The most broadly used TLD is TLD-100 (LiF:Mg,Ti) and, for applications requiring higher sensitivity to low-doses, TLD-100H (LiF:Mg,Cu,P) is frequently employed. The radiological properties of these TLDs are therefore of significant interest. For the first time, in this study effective atomic numbers for radiative, collisional and total electron interaction processes are calculated for TLD-100 and TLD-100H dosimeters over the energy range 1 keV-100 MeV. This is undertaken using a robust, energy-dependent method of calculation rather than typical power-law approximations. The influence of dopant concentrations and unwanted impurities is also investigated. The two TLDs exhibit similar effective atomic numbers, ranging from approximately 5.77-6.51. Differences arising from the different dopants are most pronounced in low-energy radiative effects. The TLDs have atomic numbers approximately 1.48-2.06 times that of water. The effective atomic number of TLD-100H is consistently higher than that of TLD-100 over a broad energy range, due to the greater influence of the higher- Z dopants on the electron interaction cross sections. Typical variation in dopant concentration does not significantly influence the effective atomic number. The influence on TLD-100H is comparatively more pronounced than that on TLD-100. Contrariwise, unwanted hydroxide impurities influence TLD-100 more than TLD-100H. The effective atomic number is a key parameter that influences the radiological properties and energy response of TLDs. Although many properties of these TLDs have been studied rigorously, as yet there has been no investigation of their effective atomic numbers for electron interactions. The

  2. OSLD energy response performance and dose accuracy at 24 - 1250 keV: Comparison with TLD-100H and TLD-100

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kadir, A. B. A.; Priharti, W.; Samat, S. B.

    OSLD was evaluated in terms of energy response and accuracy of the measured dose in comparison with TLD-100H and TLD-100. The OSLD showed a better energy response performance for H{sub p}(10) whereas for H{sub p}(0.07), TLD-100H is superior than the others. The OSLD dose accuracy is comparable with the other two dosimeters since it fulfilled the requirement of the ICRP trumpet graph analysis.

  3. The use of LiF (TLD-100) as an out-of-field dosimeter.

    PubMed

    Kry, Stephen F; Price, Michael; Followill, David; Mourtada, Firas; Salehpour, Mohammad

    2007-09-24

    The commonly used thermoluminescent dosimeter TLD-100 (Harshaw Chemical Company, Solon, OH) responds not only to photons and electrons, but also to neutrons that are produced during high-energy therapies. As a result, TLD-100 measurements outside of the treatment field are suspect when high-energy radiation is used. Although alternatives such as TLD-700 do not respond to neutrons, specialty dosimeters of this kind are expensive and are not routinely used in most clinics. In the current study, we examined the accuracy of TLD-100 in measuring the out-of-field photon dose as a function of treatment energy. To determine the accuracy of TLD-100 as compared with TLD-700, TLD-100 was irradiated outside of the treatment field by medical accelerators operated at 6, 10, 15, and 18 MV. In an effort to eliminate the response of TLD-100 to neutrons, TLD capsules were encased in varying thicknesses of cadmium foil (0.25 - 0.75 mm) before being irradiated at 18 MV. The out-of-field TLD-100 was found to be accurate at 6 MV and 10 MV, but to be substantially over-responsive at 15 MV and 18 MV (by up to 1063% relative to TLD-700). By wrapping the TLD-100 in up to 0.75 mm of cadmium, it was possible to drastically reduce (down to 39% on average) the over-response of the TLD-100; however, total removal of the over-responsiveness was not possible. Although TLD-100 is well suited for measuring out-of-field dose at energies as high as 10 MV, at higher energies (15 MV or greater), this dosimeter over-responds substantially and should not be used. Although encasing the TLD in cadmium minimized over-response to a degree, the reduction was not sufficient to make TLD-100 viable for measuring out-of-field dose at high treatment energies.

  4. Performance of Harshaw TLD-100H two-element Dosemeter.

    PubMed

    Luo, L Z; Rotunda, J E

    2006-01-01

    One of the advantages of LiF based thermoluminescent (TL) materials is its tissue-equivalent property. The Harshaw TLD-100H (LiF:Mg,Cu,P) material has demonstrated that it has a near-flat photon energy response and high sensitivity. With the optimized dosemeter filters built into the holder, the Harshaw TLD-100H two-element dosemeter can be used as a whole body personnel dosemeter for gamma, X ray and beta monitoring without the use of an algorithm or correction factor. This paper presents the dose performance of the Harshaw TLD-100H two-element dosemeter against the ANSI N13.11-2001 standard and the results of tests that are required in IEC 1066 International Standard.

  5. Investigation of LiF, Mg and Ti (TLD-100) Reproducibility.

    PubMed

    Sadeghi, M; Sina, S; Faghihi, R

    2015-12-01

    LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%.

  6. Investigation of LiF, Mg and Ti (TLD-100) Reproducibility

    PubMed Central

    Sadeghi, M.; Sina, S.; Faghihi, R.

    2015-01-01

    LiF, Mg and Ti cubical TLD chips (known as TLD-100) are widely used for dosimetry purposes. The repeatability of TL dosimetry is investigated by exposing them to doses of (81, 162 and 40.5 mGy) with 662keV photons of Cs-137. A group of 40 cubical TLD chips was randomly selected from a batch and the values of Element Correction Coefficient (ECC) were obtained 4 times by irradiating them to doses of 81 mGy (two times), 162mGy and 40.5mGy. Results of this study indicate that the average reproducibility of ECC calculation for 40 TLDs is 1.5%, while these values for all chips do not exceed 5%. PMID:26688801

  7. Response of TLD-100 in mixed fields of photons and electrons.

    PubMed

    Lawless, Michael J; Junell, Stephanie; Hammer, Cliff; DeWerd, Larry A

    2013-01-01

    Thermoluminescent dosimeters (TLDs) are routinely used for dosimetric measurements of high energy photon and electron fields. However, TLD response in combined fields of photon and electron beam qualities has not been characterized. This work investigates the response of TLD-100 (LiF:Mg,Ti) to sequential irradiation by high-energy photon and electron beam qualities. TLDs were irradiated to a known dose by a linear accelerator with a 6 MV photon beam, a 6 MeV electron beam, and a NIST-traceable (60)Co beam. TLDs were also irradiated in a mixed field of the 6 MeV electron beam and the 6 MV photon beam. The average TLD response per unit dose of the TLDs for each linac beam quality was normalized to the average response per unit dose of the TLDs irradiated by the (60)Co beam. Irradiations were performed in water and in a Virtual Water™ phantom. The 6 MV photon beam and 6 MeV electron beam were used to create dose calibration curves relating TLD response to absorbed dose to water, which were applied to the TLDs irradiated in the mixed field. TLD relative response per unit dose in the mixed field was less sensitive than the relative response in the photon field and more sensitive than the relative response in the electron field. Application of the photon dose calibration curve to the TLDs irradiated in a mixed field resulted in an underestimation of the delivered dose, while application of the electron dose calibration curve resulted in an overestimation of the dose. The relative response of TLD-100 in mixed fields fell between the relative response in the photon-only and electron-only fields. TLD-100 dosimetry of mixed fields must account for this intermediate response to minimize the estimation errors associated with calibration factors obtained from a single beam quality.

  8. Thermal and Optical Characteristics of Defect Centers in Irradiated TLD-100 Dosimeters.

    NASA Astrophysics Data System (ADS)

    Sadeghi-Zamani, Hossein

    Sensitivity loss of a sensitized LiF:Mg,Ti,Al (TLD-100) dosimeter subject to repeated standard 673 K thermal treatments has been a major problem in radiation dosimetry. The cause for this loss in radiation response of the dosimeters has not been understood. If a used TLD is not annealed at an elevated temperature prior to reuse, there are residual deep electron trap centers still present in the dosimeter. These defect centers will interact with new incoming radiation and produce thermoluminescent trap centers. This will introduce a significant error in low dose measurements. In this research, first, thermal and optical characteristics of various defect centers produced in an irradiated TLD-100 single crystal were investigated and then an improved pre-irradiation isothermal/optical treatment process was introduced to bleach the TLD dosimeters prior to reuse and reduce the loss of sensitivity of sensitized dosimeter. Thermoluminescent materials were irradiated by gamma-rays from Co-60 source to produce sufficient concentration of various defect centers, then the crystals were heated or exposed to UV light at different temperature to change the concentration of various defect centers. The change in concentration of each trap center was determined by measuring the change in absorbance of light at a fixed photon energy as a function of temperature. The thermal activation energy and the frequency factor for each trap center were evaluated assuming a first order kinetic model over a specified temperature range. The value of activation energy and the frequency factor for Z_2 ^', Z_2, Z_3, and F trap centers in TLD-100 single crystals were found to be 1.49 +/- 0.04 eV, 4.76 times 10 ^{15} sec^{ -1}, 2.23 +/- 0.02 eV, 1.65 times 10^{23 } sec^{-1}; 3.01 +/- 0.02 eV, 2.90 times 10^{17} sec ^{-1}; and 2.81 +/- 0.08 eV, 5.43 times 10 ^{17} sec^{ -1}; respectively. After a correlation was made between the trap centers and TL glow peaks, kinetic parameters obtained from absorption

  9. Response of TLD-100 in mixed fields of photons and electrons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lawless, Michael J.; Junell, Stephanie; Hammer, Cliff

    Purpose: Thermoluminescent dosimeters (TLDs) are routinely used for dosimetric measurements of high energy photon and electron fields. However, TLD response in combined fields of photon and electron beam qualities has not been characterized. This work investigates the response of TLD-100 (LiF:Mg,Ti) to sequential irradiation by high-energy photon and electron beam qualities. Methods: TLDs were irradiated to a known dose by a linear accelerator with a 6 MV photon beam, a 6 MeV electron beam, and a NIST-traceable {sup 60}Co beam. TLDs were also irradiated in a mixed field of the 6 MeV electron beam and the 6 MV photon beam.more » The average TLD response per unit dose of the TLDs for each linac beam quality was normalized to the average response per unit dose of the TLDs irradiated by the {sup 60}Co beam. Irradiations were performed in water and in a Virtual Water Trade-Mark-Sign phantom. The 6 MV photon beam and 6 MeV electron beam were used to create dose calibration curves relating TLD response to absorbed dose to water, which were applied to the TLDs irradiated in the mixed field. Results: TLD relative response per unit dose in the mixed field was less sensitive than the relative response in the photon field and more sensitive than the relative response in the electron field. Application of the photon dose calibration curve to the TLDs irradiated in a mixed field resulted in an underestimation of the delivered dose, while application of the electron dose calibration curve resulted in an overestimation of the dose. Conclusions: The relative response of TLD-100 in mixed fields fell between the relative response in the photon-only and electron-only fields. TLD-100 dosimetry of mixed fields must account for this intermediate response to minimize the estimation errors associated with calibration factors obtained from a single beam quality.« less

  10. SU-E-I-09: Application of LiF:Mg,Cu (TLD-100H) Dosimeters for in Diagnostic Radiology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sina, S; Zeinali, B; Karimipourfard, M

    Purpose: Accurate dosimetery is very essential in diagnostic radiology. The goal of this study is to verify the application of LiF:Mg,Cu,P (TLD100H) in obtaining the Entrance skin dose (ESD) of patients undergoing diagnostic radiology. The results of dosimetry performed by TLD-100H, were compared with those obtained by TLD100, which is a common dosimeter in diagnostic radiology. Methods: In this study the ESD values were measured using two types of Thermoluminescence dosimeters (TLD-100, and TLD-100H) for 16 patients undergoing diagnostic radiology (lumbar spine imaging). The ESD values were also obtained by putting the two types of TLDs at the surface ofmore » Rando phantom for different imaging techniques and different views (AP, and lateral). The TLD chips were annealed with a standard procedure, and the ECC values for each TLD was obtained by exposing the chips to equal amount of radiation. Each time three TLD chips were covered by thin dark plastic covers, and were put at the surface of the phantom or the patient. The average reading of the three chips was used for obtaining the dose. Results: The results show a close agreement between the dose measuered by the two dosimeters.According to the results of this study, the TLD-100H dosimeters have higher sensitivities (i.e.signal(nc)/dose) than TLD-100.The ESD values varied between 2.71 mGy and 26.29 mGy with the average of 11.89 mGy for TLD-100, and between 2.55 mGy and 27.41 mGy with the average of 12.32 mGy for measurements. Conclusion: The TLD-100H dosimeters are suggested as effective dosimeters for dosimetry in low dose fields because of their higher sensitivities.« less

  11. SU-E-T-172: Characterization of TLD-100 (LiF:Mg,Ti) Microcube Energy Response in a Cylindrical Chamber Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Desai, V; Hammer, C; Kunugi, K

    Purpose: To characterize the energy response of TLD-100 microcubes inside a Virtual Water chamber phantom. Methods: Four TLD microcubes were placed inside a water-proof Virtual Water (VW) chamber phantom and irradiated to a known dose on a Varian linac in a 1D water tank. These chamber phantoms were then replaced by TLD-100 chips inside a separate VW paddle and irradiated to the same dose. Each energy response reading was calculated as light output per unit dose in nC/cGy and normalized to a calibration set irradiated to the same dose in 60Co. The differences in response between the TLD chips andmore » microcubes were then analyzed. Results: Across all energies, the average microcube response was less sensitive to energy than the average chip response with both falling consistently within 2.8% of previously established values in the literature Conclusion: TLD microcubes showed a lower average sensitivity to energy than their TLD chip counterparts. The use of TLD-100 microcubes inside the chamber phantom was validated against TLD-100 chips inside of VW paddles.« less

  12. Tarjetas v.1.2015.7.23

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burchard, Ross L.; Pierson, Kathleen P.; Trumbo, Derek

    Tarjetas is used to generate requirements from source documents. These source documents are in a hierarchical XML format that have been produced from PDF documents processed through the “Reframe” software package. The software includes the ability to create Topics and associate text Snippets with those topics. Requirements are then generated and text Snippets with their associated Topics are referenced to the requirement. The software maintains traceability from the requirement ultimately to the source document that produced the snippet

  13. LiF TLD-100 as a dosimeter in high energy proton beam therapy--can it yield accurate results?

    PubMed

    Zullo, John R; Kudchadker, Rajat J; Zhu, X Ronald; Sahoo, Narayan; Gillin, Michael T

    2010-01-01

    In the region of high-dose gradients at the end of the proton range, the stopping power ratio of the protons undergoes significant changes, allowing for a broad spectrum of proton energies to be deposited within a relatively small volume. Because of the potential linear energy transfer dependence of LiF TLD-100 (thermolumescent dosimeter), dose measurements made in the distal fall-off region of a proton beam may be less accurate than those made in regions of low-dose gradients. The purpose of this study is to determine the accuracy and precision of dose measured using TLD-100 for a pristine Bragg peak, particularly in the distal fall-off region. All measurements were made along the central axis of an unmodulated 200-MeV proton beam from a Probeat passive beam-scattering proton accelerator (Hitachi, Ltd., Tokyo, Japan) at varying depths along the Bragg peak. Measurements were made using TLD-100 powder flat packs, placed in a virtual water slab phantom. The measurements were repeated using a parallel plate ionization chamber. The dose measurements using TLD-100 in a proton beam were accurate to within +/-5.0% of the expected dose, previously seen in our past photon and electron measurements. The ionization chamber and the TLD relative dose measurements agreed well with each other. Absolute dose measurements using TLD agreed with ionization chamber measurements to within +/- 3.0 cGy, for an exposure of 100 cGy. In our study, the differences in the dose measured by the ionization chamber and those measured by TLD-100 were minimal, indicating that the accuracy and precision of measurements made in the distal fall-off region of a pristine Bragg peak is within the expected range. Thus, the rapid change in stopping power ratios at the end of the range should not affect such measurements, and TLD-100 may be used with confidence as an in vivo dosimeter for proton beam therapy. Copyright 2010 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights

  14. LiF TLD-100 as a Dosimeter in High Energy Proton Beam Therapy-Can It Yield Accurate Results?

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zullo, John R.; Kudchadker, Rajat J.; Zhu, X. Ronald

    In the region of high-dose gradients at the end of the proton range, the stopping power ratio of the protons undergoes significant changes, allowing for a broad spectrum of proton energies to be deposited within a relatively small volume. Because of the potential linear energy transfer dependence of LiF TLD-100 (thermolumescent dosimeter), dose measurements made in the distal fall-off region of a proton beam may be less accurate than those made in regions of low-dose gradients. The purpose of this study is to determine the accuracy and precision of dose measured using TLD-100 for a pristine Bragg peak, particularly inmore » the distal fall-off region. All measurements were made along the central axis of an unmodulated 200-MeV proton beam from a Probeat passive beam-scattering proton accelerator (Hitachi, Ltd., Tokyo, Japan) at varying depths along the Bragg peak. Measurements were made using TLD-100 powder flat packs, placed in a virtual water slab phantom. The measurements were repeated using a parallel plate ionization chamber. The dose measurements using TLD-100 in a proton beam were accurate to within {+-}5.0% of the expected dose, previously seen in our past photon and electron measurements. The ionization chamber and the TLD relative dose measurements agreed well with each other. Absolute dose measurements using TLD agreed with ionization chamber measurements to within {+-} 3.0 cGy, for an exposure of 100 cGy. In our study, the differences in the dose measured by the ionization chamber and those measured by TLD-100 were minimal, indicating that the accuracy and precision of measurements made in the distal fall-off region of a pristine Bragg peak is within the expected range. Thus, the rapid change in stopping power ratios at the end of the range should not affect such measurements, and TLD-100 may be used with confidence as an in vivo dosimeter for proton beam therapy.« less

  15. Relative Efficiency of TLD-100 to Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

    NASA Technical Reports Server (NTRS)

    Badhwar, Gautam D.; Cash, B. L.; Semones, E. J.; Yasuda, H.; Fujitaka, K.

    1999-01-01

    Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to (137)Cs dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

  16. Relative Efficiency of TLD-100 to High Linear Energy Transfer Radiation: Correction to Astronaut Absorbed Dose

    NASA Technical Reports Server (NTRS)

    Badhwar, G. D.; Cash, B. L.; Semones, E. J.; Yasuda, H.; Fujitaka, K.

    1999-01-01

    Response of thermoluminescent detectors (TLD-100) to high linear energy transfer (LET) particles has been studied using helium, carbon, silicon, and iron ions from the Heavy Ion Medical Accelerator at Chiba (Japan), iron ions from the Brookhaven National Laboratory (NY) Alternate Gradient Synchrotron, and 53, 134, 185, and 232 MeV protons from the Loma Linda accelerator. Using the measured relative (to 137Cs) dose efficiency, and measured LET spectra from a tissue equivalent proportional counter (TEPC) on 20 Space Shuttle flights, and 7 Mir flights, the underestimation of absorbed dose by these detectors has been evaluated. The dose underestimation is between 15-20% depending upon the flight inclination and shielding location. This has been confirmed by direct correlation of measured dose by TEPC and TLD-100 at a low shielded location in the Shuttle mid-deck. A comparison of efficiency- LET data with a compilation of similar data from TLD-700, shows that shapes of the two curves are nearly identical, but that the TLD-100 curve is systematically lower by about 13%, and is the major cause of dose underestimation. These results strongly suggest that TLDs used for crew dose estimation be regularly calibrated using heavy ions.

  17. SU-E-T-137: The Response of TLD-100 in Mixed Fields of Photons and Electrons.

    PubMed

    Lawless, M; Junell, S; Hammer, C; DeWerd, L

    2012-06-01

    Thermoluminescent dosimeters are used routinely for dosimetric measurements of photon and electron fields. However, no work has been published characterizing TLDs for use in combined photon and electron fields. This work investigates the response of TLD-100 (LiF:Mg,Ti) in mixed fields of photon and electron beam qualities. TLDs were irradiated in a 6 MV photon beam, 6 MeV electron beam, and a NIST traceable cobalt-60 beam. TLDs were also irradiated in a mixed field of the electron and photon beams. All irradiations were normalized to absorbed dose to water as defined in the AAPM TG-51 report. The average response per dose (nC/Gy) for each linac beam quality was normalized to the average response per dose of the TLDs irradiated by the cobalt-60 standard.Irradiations were performed in a water tank and a Virtual Water™ phantom. Two TLD dose calibration curves for determining absorbed dose to water were generated using photon and electron field TLD response data. These individual beam quality dose calibration curves were applied to the TLDs irradiated in the mixed field. The TLD response in the mixed field was less sensitive than the response in the photon field and more sensitive than the response in the electron field. TLD determination of dose in the mixed field using the dose calibration curve generated by TLDs irradiated by photons resulted in an underestimation of the delivered dose, while the use of a dose calibration curve generated using electrons resulted in an overestimation of the delivered dose. The relative response of TLD-100 in mixed fields fell consistently between the photon nd electron relative responses. When using TLD-100 in mixed fields, the user must account for this intermediate response to avoid an over- or underestimation of the dose due to calibration in a single photon or electron field. © 2012 American Association of Physicists in Medicine.

  18. Analysis of read-out heating rate effects on the glow peaks of TLD-100 using WinGCF software

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauk, Sabar, E-mail: sabar@usm.my; Hussin, Siti Fatimah; Alam, Md. Shah

    This study was done to analyze the effects of the read-out heating rate on the LiF:Mg,Ti (TLD-100) thermoluminescent dosimeters (TLD) glow peaks using WinGCF computer software. The TLDs were exposed to X-ray photons with a potential difference of 72 kVp and 200 mAs in air and were read-out using a Harshaw 3500 TLD reader. The TLDs were read-out using four read-out heating rates at 10, 7, 4 and 1 °C s{sup −1}. It was observed that lowering the heating rate could separate more glow peaks. The activation energy for peak 5 was found to be lower than that for peakmore » 4. The peak maximum temperature and the integral value of the main peak decreased as the heating rate decreases.« less

  19. Evaluation of LiF:Mg,Ti (TLD-100) for Intraoperative Electron Radiation Therapy Quality Assurance

    PubMed Central

    Liuzzi, Raffaele; Savino, Federica; D’Avino, Vittoria; Pugliese, Mariagabriella; Cella, Laura

    2015-01-01

    Background Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2–12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters. Methods LiF:Mg,Ti dosimeters (TLD-100) were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV) and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0–10 Gy in step of 2Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy. Results The TLD-100 dose-response curves were obtained. In the dose range of 0–10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05). Conclusions This study demonstrates that the TLD dose response, for doses ≤10Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided. PMID:26427065

  20. Evaluation of LiF:Mg,Ti (TLD-100) for Intraoperative Electron Radiation Therapy Quality Assurance.

    PubMed

    Liuzzi, Raffaele; Savino, Federica; D'Avino, Vittoria; Pugliese, Mariagabriella; Cella, Laura

    2015-01-01

    Purpose of the present work was to investigate thermoluminescent dosimeters (TLDs) response to intraoperative electron radiation therapy (IOERT) beams. In an IOERT treatment, a large single radiation dose is delivered with a high dose-per-pulse electron beam (2-12 cGy/pulse) during surgery. To verify and to record the delivered dose, in vivo dosimetry is a mandatory procedure for quality assurance. The TLDs feature many advantages such as a small detector size and close tissue equivalence that make them attractive for IOERT as in vivo dosimeters. LiF:Mg,Ti dosimeters (TLD-100) were irradiated with different IOERT electron beam energies (5, 7 and 9 MeV) and with a 6 MV conventional photon beam. For each energy, the TLDs were irradiated in the dose range of 0-10 Gy in step of 2 Gy. Regression analysis was performed to establish the response variation of thermoluminescent signals with dose and energy. The TLD-100 dose-response curves were obtained. In the dose range of 0-10 Gy, the calibration curve was confirmed to be linear for the conventional photon beam. In the same dose region, the quadratic model performs better than the linear model when high dose-per-pulse electron beams were used (F test; p<0.05). This study demonstrates that the TLD dose response, for doses ≤10 Gy, has a parabolic behavior in high dose-per-pulse electron beams. TLD-100 can be useful detectors for IOERT patient dosimetry if a proper calibration is provided.

  1. TLD linearity vs. beam energy and modality.

    PubMed

    Troncalli, Andrew J; Chapman, Jane

    2002-01-01

    Thermoluminescent dosimetry (TLD) is considered to be a valuable dosimetric tool in determining patient dose. Lithium fluoride doped with magnesium and titanium (TLD-100) is widely used, as it does not display widely divergent energy dependence. For many years, we have known that TLD-100 shows supralinearity to dose. In a radiotherapy clinic, there are multiple energies and modality beams. This work investigates whether individual linearity corrections must be used for each beam or whether a single correction can be applied to all beams. The response of TLD as a function of dose was measured from 25 cGy to 1000 cGy on both electrons and photons from 6 to 18 MeV. This work shows that, within our measurement uncertainty, TLD-100 exhibits supralinearity at all megavoltage energies and modalities.

  2. X-ray surface dose measurements using TLD extrapolation.

    PubMed

    Kron, T; Elliot, A; Wong, T; Showell, G; Clubb, B; Metcalfe, P

    1993-01-01

    Surface dose measurements in therapeutic x-ray beams are of importance in determining the dose to the skin of patients undergoing radiotherapy. Measurements were performed in the 6-MV beam of a medical linear accelerator with LiF thermoluminescence dosimeters (TLD) using a solid water phantom. TLD chips (surface area 3.17 x 3.17 cm2) of three different thicknesses (0.230, 0.099, and 0.038 g/cm2) were used to extrapolate dose readings to an infinitesimally thin layer of LiF. This surface dose was measured for field sizes ranging from 1 x 1 cm2 to 40 x 40 cm2. The surface dose relative to maximum dose was found to be 10.0% for a field size of 5 x 5 cm2, 16.3% for 10 x 10 cm2, and 26.9% for 20 x 20 cm2. Using a 6-mm Perspex block tray in the beam increased the surface dose in these fields to 10.7%, 17.7%, and 34.2% respectively. Due to the small size of the TLD chips, TLD extrapolation is applicable also for intracavity and exit dose determinations. The technique used for in vivo dosimetry could provide clinicians information about the build up of dose up to 1-mm depth in addition to an extrapolated surface dose measurement.

  3. A comparative evaluation of luminescence detectors: RPL-GD-301, TLD-100 and OSL-AL2O3:C, using Monte Carlo simulations

    NASA Astrophysics Data System (ADS)

    Benali, A.-H.; Medkour Ishak-Boushaki, G.; Nourreddine, A.-M.; Allab, M.; Papadimitroulas, P.

    2017-07-01

    The luminescent dosimeters are widely used in clinical practice, for the monitoring of patient dose in external radiation therapy. Three of the most common dosimeter categories are the thermoluminescence (TLDs), the radiophotoluminescence (RPLs) and the optically stimulated luminescence (OSLs), with similar physical processes on their properties. The aim of the present study is to compare and evaluate the dosimetric properties of three specific luminescent detectors namely: a) RPL glass dosimeter, commercially known as GD-301, b) lithium fluoride TLD-100 (LiF:Mg,Ti) and c) carbon-doped aluminum oxide (Al2O3:C). For this purpose, Monte Carlo simulations were applied, using the MCNP5 code to estimate the responses of these dosimeters in terms of absorbed dose, output factor, the angular and energy dependence. In the present study, we found that the differences between the output factors were less than ± 4.2% for all detector materials RPLGD, TLD and OSLD. The variations in sensitivity for angles up to ± 80 degrees from the central axis of the beam were approximately 0.5%, 0.8% and 1.5% for the TLD-100, GD-301 and Al2O3:C, respectively. The energy dependence of the RPL and OSL dosimeters are stated as less than a 2.2%, and within 5.8% for TLD.

  4. Thermoluminescent response of TLD-100 irradiated with 20 keV electrons and the use of radiochromic dye films for the fluence determination

    NASA Astrophysics Data System (ADS)

    Mercado-Uribe, H.; Brandan, M. E.

    2004-07-01

    We have measured the LiF:Mg,Ti (TLD-100) fluence response and supralinearity function to 20 keV electrons in the fluence interval between 5 × 10 9 and 4 × 10 12 cm -2. TLD-100 shows linear response up to 2 × 10 10 cm -2, followed by supralinearity and saturation after 10 12 cm -2. Peak 5 is slightly supralinear, f( n) max=1.1±0.1, while high temperature peaks reach up to f( n) max≈8. Peak 5 saturates at n≈1×10 11 cm -2, fluence smaller than any of the saturating fluences of the high temperature peaks. We have also measured the glow curve shape of TLD-100 irradiated with 40 keV electrons, beta particles from a 90Sr/ 90Y source and 1.3 and 6.0 MeV electrons from accelerators. Results are interesting and unexpected in that, for a given macroscopic dose, electrons show a smaller relative contribution of high-temperature peaks with respect to peak 5 than heavy ions or X- and γ-rays. The 20 and 40 keV electron irradiations were performed with a scanning electron microscope using radiochromic dye film to measure fluence. Since film calibrations were performed using 60Co γ-rays which expose the totality of the film volume, the use of this method with low energy electrons required to develop a formalism that takes into account the sensitive thickness of the film in relation to the range of the incident particles.

  5. Characterization of TLD-100 micro-cubes for use in small field dosimetry

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Peña-Jiménez, Salvador, E-mail: zoid-9861@yahoo.com.mx; Gamboa-deBuen, Isabel, E-mail: gamboa@nucleares.unam.mx; Lárraga-Gutiérrez, José Manuel, E-mail: jose.larraga.gtz@gmail.com, E-mail: amanda.garcia.g@gmail.com

    At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose wasmore » determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.« less

  6. Characterization of TLD-100 micro-cubes for use in small field dosimetry

    NASA Astrophysics Data System (ADS)

    Peña-Jiménez, Salvador; Lárraga-Gutiérrez, José Manuel; García-Garduño, Olivia Amanda; Gamboa-deBuen, Isabel

    2014-11-01

    At present there are no international regulations for the management of millimeter scale fields and there are no suggestions for a reference detector to perform the characterization and dose determination for unconventional radiation beams (small fields) so that the dosimetry of small fields remains an open research field worldwide because these fields are used in radiotherapy treatments. Sensitivity factors and reproducibility of TLD-100 micro-cubes (1×1×1 mm3) were determinate irradiating the dosimeters with a 6 MV beam in a linear accelerator dedicated to radiosurgery at the Instituto Nacional de Neurología y Neurocirugía (INNN). Thermoluminescent response as a function of dose was determined for doses in water between 0.5 and 3 Gy and two field sizes (2×2 cm2 and 10×10 cm2). It was found that the response is linear over the dose range studied and it does not depend on field size.

  7. Thermoluminescent response of LiF (TLD-100) to 5-30 keV electrons and the effect of annealing in various atmospheres.

    PubMed

    Lasky, J B; Moran, P R

    1977-09-01

    The response of single crystal and extruded ribbons of TLD-100 to 5-30 keV electrons was investigated. If annealing is done in a vacuum, the sensitivity of TLD-100 single crystals to these electrons and the resultant glow curve are essentially the same as when irradiation are carried out with 137Cs gamma rays. All discrepancies in sensitivity can then be accounted for by the higher LET of electrons. The commonly used 'standard annealing' at 400 degrees C for one hour produced a change in the glow curve shape and a loss in sensitivity in contrast to the vacuum anneal results. Diffusion of hydroxyl ions into the sample during air annealing is believed to be the primary cause for this change. These results explain the source of the 'dead layer' proposed to explain the variation with particle size of the luminescent efficiency of X-ray irradiated TLD-100 powder and the low TL efficiency from low energy electron irradiations. With the use of the vacuum annealing procedure, the same sensitivity and reproducibility can be achieved for the dosimetry of low energy electrons and other shallowly penetrating radiation as is currently achieved for the dosimetry of X-rays.

  8. Determination of the Sensibility Factors for TLD-100 Powder on the Energy of X-Ray of 50, 250 kVp; 192Ir, 137Cs and 60Co

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Loaiza, Sandra P.; Alvarez, Jose T.

    2006-09-08

    TLD-100 powder is calibrated in terms of absorbed dose to water Dw, using the protocols AAPM TG61, AAPM TG43 and IAEA-TRS 398, for the energy of RX 50, 250 kVp, 137Cs and 60Co respectively. The calibration curves, TLD Response R versus Dw, are fitted by weighted least square by a quadratic polynomials; which are validated with the lack of fit and the Anderson-Darling normality test. The slope of these curves corresponds to the sensibility factor: Fs R/DW, [Fs] = nC Gy-1. The expanded uncertainties U's for these factors are obtained from the ANOVA tables. Later, the Fs' values are interpolatedmore » using the effective energy hvefec for the 192Ir. The SSDL sent a set of capsules with powder TLD-100 for two Hospitals. These irradiated them a nominal dose of Dw = 2 Gy. The results determined at SSDL are: for the Hospital A the Dw is overestimated in order to 4.8% and the Hospital B underestimates it in the range from -1.4% to -17.5%.« less

  9. Monte Carlo simulation of depth-dose distributions in TLD-100 under 90Sr-90Y irradiation.

    PubMed

    Rodríguez-Villafuerte, M; Gamboa-deBuen, I; Brandan, M E

    1997-04-01

    In this work the depth-dose distribution in TLD-100 dosimeters under beta irradiation from a 90Sr-90Y source was investigated using the Monte Carlo method. Comparisons between the simulated data and experimental results showed that the depth-dose distribution is strongly affected by the different components of both the source and dosimeter holders due to the large number of electron scattering events.

  10. TLD and OSLD dosimetry systems for remote audits of radiotherapy external beam calibration.

    PubMed

    Alvarez, P; Kry, S F; Stingo, F; Followill, D

    2017-11-01

    The Imaging and Radiation Oncology Core QA Center in Houston (IROC-H) performs remote dosimetry audits of more than 20,000 megavoltage photon and electron beams each year. Both a thermoluminescent dosimeter (TLD-100) and optically stimulated luminescent dosimeter (OSLD; nanoDot) system are commissioned for this task, with the OSLD system being predominant due to the more time-efficient read-out process. The measurement apparatus includes 3 TLD or 2 OSLD in an acrylic mini-phantom, which are irradiated by the institution under reference geometry. Dosimetry systems are calibrated based on the signal-to-dose conversion established with reference dosimeters irradiated in a Co-60 beam, using a reference dose of 300 cGy for TLD and 100 cGy for OSLD. The uncertainty in the dose determination is 1.3% for TLD and 1.6% for OSLD at the one sigma level. This accuracy allows for a tolerance of ±5% to be used.

  11. Developmental roles of the BMP1/TLD metalloproteinases.

    PubMed

    Ge, Gaoxiang; Greenspan, Daniel S

    2006-03-01

    The astacin family (M12A) of the metzincin subclan MA(M) of metalloproteinases has been detected in developing and mature individuals of species that range from hydra to humans. Functions of this family of metalloproteinase vary from digestive degradation of polypeptides, to biosynthetic processing of extracellular proteins, to activation of growth factors. This review will focus on a small subgroup of the astacin family; the bone morphogenetic protein 1 (BMP1)/Tolloid (TLD)-like metalloproteinases. In vertebrates, the BMP1/TLD-like metalloproteinases play key roles in regulating formation of the extracellular matrix (ECM) via biosynthetic processing of various precursor proteins into mature functional enzymes, structural proteins, and proteins involved in initiating mineralization of the ECM of hard tissues. Roles in ECM formation include: processing of the C-propeptides of procollagens types I-III, to yield the major fibrous components of vertebrate ECM; proteolytic activation of the enzyme lysyl oxidase, necessary to formation of covalent cross-links in collagen and elastic fibers; processing of NH2-terminal globular domains and C-propeptides of types V and XI procollagen chains to yield monomers that are incorporated into and control the diameters of collagen type I and II fibrils, respectively; processing of precursors for laminin 5 and collagen type VII, both of which are involved in securing epidermis to underlying dermis; and maturation of small leucine-rich proteoglycans. The BMP1/TLD-related metalloproteinases are also capable of activating the vertebrate transforming growth factor-beta (TGF-beta)-like "chalones" growth differentiation factor 8 (GDF8, also known as myostatin), and GDF11 (also known as BMP11), involved in negative feedback inhibition of muscle and neural tissue growth, respectively; by freeing them from noncovalent latent complexes with their cleaved prodomains. BMP1/TLD-like proteinases also liberate the vertebrate TGF

  12. On the determination of the post-irradiation time from the glow curve of TLD-100.

    PubMed

    Weinstein, M; German, U; Dubinsky, S; Alfassi, Z B

    2003-01-01

    The ratio of peak 3 to the sum of peaks 4 + 5 in TLD-100 was measured for various pre-irradiation and post-irradiation time periods, under conditions characteristic of routine personal dosimetry. It was confirmed that the value of this ratio depends only on the elapsed time between the prior readout and the present one, independent of the moment when the irradiation took place during the total time interval (storage time). This effect indicates that fading of peak 3 seems to be due mainly to changes in the unoccupied traps, and not to decay of trapped charges, being almost independent of the presence of electrons or holes in the traps. This observation leads to the conclusion that the suggestions in the past to use the decay of peak 3 in TLD-100 for the measurement of the elapsed time between irradiation and readout may have been wrong. On the other hand, the decay of peak 2 can be used to measure the elapsed time from irradiation, since the rate of decay is different when related to pre-irradiation and post-irradiation times, indicating a much higher decay rate of the trapped charges (Randall-Wilkins decay). However, because of the fast decay rate of peak 2, its use for determination of the elapsed time since irradiation is of little practical significance.

  13. Effect of heating rate on thermoluminescence output of LiF: Mg, Ti (TLD-100) in dosimetric applications

    NASA Astrophysics Data System (ADS)

    Singh, Ranjit; Kainth, Harpreet Singh

    2018-07-01

    The luminiscence characteristics of thermoluminscence dosimeter LiF: Mg, Ti (TLD-100) irradiated to X-rays from 6 MV linac have been studied for wide range of 2-50 K/s readout linear heating rates. The reproducibility of glow curves for TLDs is found to be better at lower heating rates and depreciate at higher heating rates. The glow curve spectra were analysed using deconvolution procedure based on general-order kinetics. Shift in the peak maximum temperature per unit rise in heating rate for various peaks were found to decrease with heating rate. The TLDs irradiated with same dose exhibit decreasing TL counts with increase in the heating rate, which indicate the thermal quenching effect in TLD-100. The value of activation energy for each peak within the glow curve increases with heating rate. Calibration curves plotted for the dose range 0.4-1020 cGy exhibit decreasing slope with increasing readout heating rate. Corrections for temperature lag between the heating element and the dosimeter, and the effective heating rate (βeff) across the sample estimated using formulation proposed by Kitis and Tuyn and are found to be fairly applicable.

  14. Response of thermoluminescent lithium fluoride (TLD-100) to photon beams of 275, 400, 500, 600, 730, 900, 1200, 1500, and 2500 eV.

    PubMed

    Carrillo, R E; Pearson, D W; DeLuca, P M; MacKay, J F; Lagally, M G

    1994-11-01

    LiF:Mg,Ti (TLD-100) extruded ribbons and cleaved crystals were exposed to monoenergetic photons of 275-2550 eV energy to determine their potential usefulness as radiation dosimeters for radiobiology experiments at these energies. The radiation source was synchrotron radiation from the 1 GeV electron storage ring, Aladdin. The authors report TLD response and glow curves for He- and air-annealed dosimeters. The undesirable effects of air annealing increase with decreasing photon penetration in the dosimeter. Under certain experimental conditions, UV radiation produced anomalous bleaching of high-temperature traps. The crystals and the chips presented a supralinear response, Supralinearity factors were determined to be of the order of 1.5 for crystals, and 1.7 for the chips. The authors' results indicate that TLDs are a reliable means to monitor the total energy deposited in irradiated cells and are now used routinely for radiobiology cell irradiations.

  15. Depth dose and off-axis characteristics of TLD in therapeutic pion beams.

    PubMed

    Hogstrom, K R; Irifune, T

    1980-07-01

    The thermoluminescent (TL) response of LiF (TLD-100, TLD-600, TLD-700) and Li2B4O7 (TLD-800) has been measured as a function of depth and off-axis position in a therapeutic negative-pion beam in order to evaluate their usefulness in pion radiotherapy. TLD-100, TLD-600, and TLD-800 have been shown to be of little use as in vivo dosemeters because the neutron kerma relative to that in tissue changes grossly with depth. The neutron source comes primarily from pion absorption in the lead-alloy collimator. The 200 degrees C TLD-700 response agrees well with the depth dose spectra, except for small changes due to the varying linear energy transfer (LET) distributions. This variation can be partially accounted for by incorporating the known LET response of LiF. The 260 degrees C peak of TLD-700 has been found to be approximately four times more sensitive than the 200 degrees C peak to high LET dose. Using a simple model of the LET responses, the measured 200 degrees C and 260 degrees C peaks predict total dose within +/- 4% and high LET dose within +/- 50%, therefore indicating TLD-700 to be a good in vivo dosemeter for total dose but only an indicator of high LET dose.

  16. SU-E-T-308: Systematic Characterization of the Energy Response of Different LiF TLD Crystals for Dosimetry Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pena, E; Caprile, P; Sanchez-Nieto, B

    Purpose: The thermoluminiscense dosimeters (TLDs) are widely used in personal and clinical dosimetry due to its small size, good sensitivity and tissue equivalence, among other advantages. This study presents the characterization of Lithium Fluoride based TLDs, in terms of their absorbed dose response to successive irradiation cycles in a broad range of beam energies, measured under reference conditions. Methods: Four types of Harshaw TLD chips were used: TLD-100, TLD-600 TLD-700 and 100-H. They were irradiated with 10 photon beams of different energy spectrums, from 28 kVp to 18MV (in 30 consecutive cycles for 6 and 18 MV). Results: It wasmore » found that the response of the dosimetric system was stabilized (less than ±3%) after 10 cycles for TLD-600 and TLD-700. In the case of TLD-100 and TLD-100H this dependence was not observed. A decreased response to increasing beam energy in terms of absorbed dose to water was observed, as expected, except for TLD-100H which showed the opposite behavior. The less energy dependent detector was the TLD-100H exhibiting a maximum deviation of 12%. The highest variation observed was 33% for TLD-100. The study allowed the determination of calibration factors in absorbed dose for a wide range of energies and materials for different dosimetric applications, such as in-vivo dosimetry during imaging and radiotherapy. Conclusion: The study allowed the determination of calibration factors in absorbed dose for a wide range of energies and materials for different dosimetric applications, such as in-vivo dosimetry during imaging and radiotherapy.« less

  17. Environmental monitoring through use of silica-based TLD.

    PubMed

    Rozaila, Z Siti; Khandaker, M U; Abdul Sani, S F; Sabtu, Siti Norbaini; Amin, Y M; Maah, M J; Bradley, D A

    2017-09-25

    The sensitivity of a novel silica-based fibre-form thermoluminescence dosimeter was tested off-site of a rare-earths processing plant, investigating the potential for obtaining baseline measurements of naturally occurring radioactive materials. The dosimeter, a Ge-doped collapsed photonic crystal fibre (PCFc) co-doped with B, was calibrated against commercially available thermoluminescent dosimetry (TLD) (TLD-200 and TLD-100) using a bremsstrahlung (tube-based) x-ray source. Eight sampling sites within 1 to 20 km of the perimeter of the rare-earth facility were identified, the TLDs (silica- as well as TLD-200 and TLD-100) in each case being buried within the soil at fixed depth, allowing measurements to be obtained, in this case for protracted periods of exposure of between two to eight months. The values of the dose were then compared against values projected on the basis of radioactivity measurements of the associated soils, obtained via high-purity germanium gamma-ray spectrometry. Accord was found in relative terms between the TL evaluations at each site and the associated spectroscopic results. Thus said, in absolute terms, the TL evaluated doses were typically less than those derived from gamma-ray spectroscopy, by ∼50% in the case of PCFc-Ge. Gamma spectrometry analysis typically provided an upper limit to the projected dose, and the Marinelli beaker contents were formed from sieving to provide a homogenous well-packed medium. However, with the radioactivity per unit mass typically greater for smaller particles, with preferential adsorption on the surface and the surface area per unit volume increasing with decrease in radius, this made for an elevated dose estimate. Prevailing concentrations of key naturally occurring radionuclides in soil, 226 Ra, 232 Th and 40 K, were also determined, together with radiological dose evaluation. To date, the area under investigation, although including a rare-earth processing facility, gives no cause for concern from

  18. Evaluation of Effective Sources in Uncertainty Measurements of Personal Dosimetry by a Harshaw TLD System

    PubMed Central

    Hosseini Pooya, SM; Orouji, T

    2014-01-01

    Background: The accurate results of the individual doses in personal dosimety which are reported by the service providers in personal dosimetry are very important. There are national / international criteria for acceptable dosimetry system performance. Objective: In this research, the sources of uncertainties are identified, measured and calculated in a personal dosimetry system by TLD. Method: These sources are included; inhomogeneity of TLDs sensitivity, variability of TLD readings due to limited sensitivity and background, energy dependence, directional dependence, non-linearity of the response, fading, dependent on ambient temperature / humidity and calibration errors, which may affect on the dose responses. Some parameters which influence on the above sources of uncertainty are studied for Harshaw TLD-100 cards dosimeters as well as the hot gas Harshaw 6600 TLD reader system. Results: The individual uncertainties of each sources was measured less than 6.7% in 68% confidence level. The total uncertainty was calculated 17.5% with 95% confidence level. Conclusion: The TLD-100 personal dosimeters as well as the Harshaw TLD-100 reader 6600 system show the total uncertainty value which is less than that of admissible value of 42% for personal dosimetry services. PMID:25505769

  19. Mass: 100 mg, 10 g, 100 g, 1 kg, 10 kg and 50 kg

    NASA Astrophysics Data System (ADS)

    Kaçmaz, Sevda; Davidson, Stuart

    2017-01-01

    Bilateral mass comparison of mass standards of 100 mg, 2 g, 20 g, 500 g and 10 kg was carried out in 2011 to 2012 between UME and NPL. UME was the pilot laboratory. For all mass standards, the results show adequate agreement between the laboratories. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  20. Phenomenological study of the ionisation density-dependence of TLD-100 peak 5a.

    PubMed

    Brandan, Maria-Ester; Angeles, Oscar; Mercado-Uribe, Hilda

    2006-01-01

    Horowitz and collaborators have reported evidence on the structure of TLD-100 peak 5. A satellite peak, called 5a, has been singled out as arising from localised electron-hole recombination in a trap/luminescent centre, its emission mechanism would be geminate recombination and, therefore, its population would depend on incident radiation ionisation density. We report a phenomenological study of peak 4, 5a and 5 strengths for glow curves previously measured at UNAM for gammas, electrons and low-energy ions. The deconvolution procedure has followed strict rules to assure that the glow curve, where the presence of peak 5a is not visually noticeable, is decomposed in a consistent fashion, maintaining fixed widths and relative temperature difference between all the peaks. We find no improvement in the quality of the fit after inclusion of peak 5a. The relative contribution of peak 5a with respect to peak 5 does not seem to correlate with the radiation linear energy transfer.

  1. Poster - 24: Characterization of the energy dependence of high-sensitivity MCP-N TLD and Al2O3:C OSLD in-vivo dosimetry systems for 40–100 kVp energies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Poirier, Yannick; Kuznetsova, Svetlana; Barajas, E

    Purpose: To characterize the energy dependence of high-sensitivity MCP-N TLD and Al{sub 2}O{sub 3}:C OSLD dosimetry systems at low (40–100 kVp) energies for in-vivo dosimetry. Methods: We assessed the variation of response with energy of two detectors in the 40–100 kVp energy range: high-sensitivity MCP-N TLDs (LiF:Mg,Cu,P) and OSLDs (Al{sub 2}O{sub 3}:C). The detectors were irradiated with an XRad 320ix biological irradiator under reference conditions. The delivered dose was 10 cGy for 7 beam qualities ranging from 40–100 kVp, 1.7–4.0 mm Al, and effective energies 26.9–37.9 keV. Both sets of detectors were also irradiated under reference conditions at 6 MVmore » using a Varian Clinac 21Ex to assess the change in response from high-energy beams. Results: The MCP-N high-sensitivity TLDs were relatively insensitive to energies in the kV range, as their response varied by ±5%, i.e. well within the reproducibility limits of these detectors. However, the OSLDs exhibited a linearly-decreasing response with energy with a response 18.7% higher at 40 kVp than at 100 kVp for the same nominal dose. Compared to the 6 MV beams used in conventional radiotherapy, OSLDs responded 3.3–3.9 times higher depending on beam quality while the MCP-N TLD response was unchanged within experimental uncertainty. Conclusions: Unlike the more commonly used TLD-100, the high-sensitivity MCP-N TLDs exhibit little to no energy response. OSLDs are shown to be highly energy-dependent, both from MV to kV and within the kV range.« less

  2. The dose-response of Harshaw TLD-700H.

    PubMed

    Velbeck, K J; Luo, L Z; Ramlo, M J; Rotunda, J E

    2006-01-01

    Harshaw TLD-700H (7LiF:Mg,Cu,P) was previously characterised for low- to high-dose ranges from 1 microGy to 20 Gy. This paper describes the studies and results of dose-response and linearity at much higher doses. TLD-700H is a near perfect dosimetric material with near tissue equivalence, flat energy response, and the ability to measure beta, gamma and X rays. These new results extend the applicability of Harshaw TLD-700H into more dosimetric measurement environments. The simple glow curve structure provides insignificant fade, eliminating special oven preparation methods experienced by other materials. The work presented in this paper quantifies the performance of Harshaw TLD-700H in extended ranges.

  3. Ge and B doped collapsed photonic crystal optical fibre, a potential TLD material for low dose measurements

    NASA Astrophysics Data System (ADS)

    Rozaila, Z. Siti; Alyahyawi, Amjad; Khandaker, M. U.; Amin, Y. M.; Bradley, D. A.; Maah, M. J.

    2016-09-01

    Offering a number of advantageous features, tailor-made silica-based fibres are attracting attention as thermoluminesence (TL) dosimeters. We have performed a detailed study of the TL properties of Ge-doped and Ge-B-doped collapsed photonic crystal fibres (PCFc), most particularly with regard to their potential use for the environmental and X-ray diagnostic dose monitoring. Extrinsic doping and defects generated by strain at the fused inner walls of the collapsed fibres result in the PCFc-Ge-B and PCFc-Ge fibres producing markedly greater TL response than that of the phosphor-based dosimeter TLD-100, by some 9 and 7×, respectively. The linearity of TL yield has been investigated for X-ray doses from 0.5 mGy to 10 mGy. For a dose of 1 Gy, the energy response of the PCFs and TLD-100 has been studied using X-rays generated at accelerating potentials from 20 kVp through to 200 kVp and for the 1.25 MeV mean gamma-ray energy from 60Co. The effective atomic number , Zeffof PCFc-Ge and PCFc-Ge-B was estimated to be 12.5 and 14.4, respectively. Some 35 days post-irradiation, fading of the stored TL signal from PCFc-Ge-B and PCFc-Ge were found to be ∼15% and 20% respectively, with mean loss in TL emission of 0.4-0.5% per day. The present doped-silica collapsed PCFs provide greatly improved TLD performance compared to that of previous fibre designs and phosphor-based TLD-100.

  4. SU-G-201-08: Energy Response of Thermoluminescent Microcube Dosimeters in Water for Kilovoltage X-Ray Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Di Maso, L; Lawless, M; Culberson, W

    Purpose: To characterize the energy dependence for TLD-100 microcubes in water at kilovoltage energies. Methods: TLD-100 microcubes with dimensions of (1 × 1 × 1) mm{sup 3} were irradiated with kilovoltage x-rays in a custom-built thin-window liquid water phantom. The TLD-100 microcubes were held in Virtual Water™ probes and aligned at a 2 cm depth in water. Irradiations were performed using the M-series x-ray beams of energies ranging from 50-250 kVp and normalized to a {sup 60}Co beam located at the UWADCL. Simulations using the EGSnrc Monte Carlo Code System were performed to model the x-ray beams, the {sup 60}Comore » beam, the water phantom and the dosimeters in the phantom. The egs-chamber user code was used to tally the dose to the TLDs and the dose to water. The measurements and calculations were used to determine the intrinsic energy dependence, absorbed-dose energy dependence, and absorbed-dose sensitivity. These values were compared to TLD-100 chips with dimensions of (3.2 × 0.9 × 0.9) mm{sup 3}. Results: The measured TLD-100 microcube response per dose to water among all investigated x-ray energies had a maximum percent difference of 61% relative to {sup 60}Co. The simulated ratio of dose to water to the dose to TLD had a maximum percent difference of 29% relative to {sup 60}Co. The ratio of dose to TLD to the TLD output had a maximum percent difference of 13% relative to {sup 60}Co. The maximum percent difference for the absorbed-dose sensitivity was 15% more than the used value of 1.41. Conclusion: These results confirm that differences in beam quality have a significant effect on TLD response when irradiated in water. These results also indicated a difference in TLD-100 response between microcube and chip geometries. The intrinsic energy dependence and the absorbed-dose energy dependence deviated up to 10% between TLD-100 microcubes and chips.« less

  5. SU-F-19A-06: Experimental Investigation of the Energy Dependence of TLD Sensitivity in Low-Energy Photon Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Z; Nath, R

    Purpose: To measure the energy dependence of TLD sensitivity in lowenergy photon beams with equivalent mono-energetic energy matching those of 103Pd, 125I and 131Cs brachytherapy sources. Methods: A Pantek DXT 300 x-ray unit (Precision X-ray, Branford, CT), with stable digital voltage control down to 20 kV, was used to establish three lowenergy photon beams with narrow energy spread and equivalent monoenergetic energies matching those of 103Pd, 125I and 131Cs brachytherapy sources. The low-energy x-ray beams and a reference 6 MV photon beam were calibrated according to the AAPM TG-61 and TG-51 protocols, respectively, using a parallel-plate low-energy chamber and amore » Farmer cylindrical chamber with NIST traceable calibration factors. The dose response of model TLD-100 micro-cubes (1×1×1 mm{sup 3}) in each beam was measured for five different batches of TLDs (each contained approximately 100 TLDs) that have different histories of irradiation and usage. Relative absorbed dose sensitivity was determined as the quotient of the slope of dose response for a beam-of-interest to that of the reference beam. Results: Equivalent mono-energetic photon energies of the low-energy beams established for 103Pd, 125I and 131Cs sources were 20.5, 27.5, and 30.1 keV, respectively. Each beam exhibited narrow spectral spread with energyhomogeneity index close to 90%. The relative absorbed-dose sensitivity was found to vary between different batches of TLD with maximum differences of up to 8%. The mean and standard deviation determined from the five TLD batches was 1.453 ± 0.026, 1.541 ± 0.035 and 1.529 ± 0.051 for the simulated 103P, 125I and 131Cs beams, respectively. Conclusion: Our measured relative absorbed-dose sensitivities are greater than the historically measured value of 1.41. We find that the relative absorbed-dose sensitivity of TLD in the 103P beam is approximately 5% lower than that of 125I and 131Cs beams. Comparison of our results with other studies will be

  6. SU-E-T-594: Out-Of-Field Neutron and Gamma Dose Estimated Using TLD-600/700 Pairs in the Wobbling Proton Therapy System

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Y; Lin, Y; Medical Physics Research Center, Institute for Radiological Research, Chang Gung University / Chang Gung Memorial Hospital, Linkou, Taoyuan, Taiwan

    Purpose: Secondary fast neutrons and gamma rays are mainly produced due to the interaction of the primary proton beam with the beam delivery nozzle. These secondary radiation dose to patients and radiation workers are unwanted. The purpose of this study is to estimate the neutron and gamma dose equivalent out of the treatment volume during the wobbling proton therapy system. Methods: Two types of thermoluminescent (TL) dosimeters, TLD-600 ({sup 6}LiF: Mg, Ti) and TLD-700 ({sup 7}LiF: Mg, Ti) were used in this study. They were calibrated in the standard neutron and gamma sources at National Standards Laboratory. Annealing procedure ismore » 400°C for 1 hour, 100°C for 2 hours and spontaneously cooling down to the room temperature in a programmable oven. Two-peak method (a kind of glow curve analysis technique) was used to evaluate the TL response corresponding to the neutron and gamma dose. The TLD pairs were placed outside the treatment field at the neutron-gamma mixed field with 190-MeV proton beam produced by the wobbling system through the polyethylene plate phantom. The results of TLD measurement were compared to the Monte Carlo simulation. Results: The initial experiment results of calculated dose equivalents are 0.63, 0.38, 0.21 and 0.13 mSv per Gy outside the field at the distance of 50, 100, 150 and 200 cm. Conclusion: The TLD-600 and TLD-700 pairs are convenient to estimate neutron and gamma dosimetry during proton therapy. However, an accurate and suitable glow curve analysis technique is necessary. During the wobbling system proton therapy, our results showed that the neutron and gamma doses outside the treatment field are noticeable. This study was supported by the grants from the Chang Gung Memorial Hospital (CMRPD1C0682)« less

  7. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study

    PubMed Central

    Schulze, D; Wolff, J; Rottke, D

    2014-01-01

    Objectives: The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Methods: Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO® head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). Results: The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; −5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; −14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; −16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Conclusions: Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region. PMID:25143020

  8. Effective dose assessment in the maxillofacial region using thermoluminescent (TLD) and metal oxide semiconductor field-effect transistor (MOSFET) dosemeters: a comparative study.

    PubMed

    Koivisto, J; Schulze, D; Wolff, J; Rottke, D

    2014-01-01

    The objective of this study was to compare the performance of metal oxide semiconductor field-effect transistor (MOSFET) technology dosemeters with thermoluminescent dosemeters (TLDs) (TLD 100; Thermo Fisher Scientific, Waltham, MA) in the maxillofacial area. Organ and effective dose measurements were performed using 40 TLD and 20 MOSFET dosemeters that were alternately placed in 20 different locations in 1 anthropomorphic RANDO(®) head phantom (the Phantom Laboratory, Salem, NY). The phantom was exposed to four different CBCT default maxillofacial protocols using small (4 × 5 cm) to full face (20 × 17 cm) fields of view (FOVs). The TLD effective doses ranged between 7.0 and 158.0 µSv and the MOSFET doses between 6.1 and 175.0 µSv. The MOSFET and TLD effective doses acquired using four different (FOV) protocols were as follows: face maxillofacial (FOV 20 × 17 cm) (MOSFET, 83.4 µSv; TLD, 87.6 µSv; -5%); teeth, upper jaw (FOV, 8.5 × 5.0 cm) (MOSFET, 6.1 µSv; TLD, 7.0 µSv; -14%); tooth, mandible and left molar (FOV, 4 × 5 cm) (MOSFET, 10.3 µSv; TLD, 12.3 µSv; -16%) and teeth, both jaws (FOV, 10 × 10 cm) (MOSFET, 175 µSv; TLD, 158 µSv; +11%). The largest variation in organ and effective dose was recorded in the small FOV protocols. Taking into account the uncertainties of both measurement methods and the results of the statistical analysis, the effective doses acquired using MOSFET dosemeters were found to be in good agreement with those obtained using TLD dosemeters. The MOSFET dosemeters constitute a feasible alternative for TLDs for the effective dose assessment of CBCT devices in the maxillofacial region.

  9. Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations

    PubMed Central

    Nedaie, Hassan Ali; Darestani, Hoda; Banaee, Nooshin; Shagholi, Negin; Mohammadi, Kheirollah; Shahvar, Arjang; Bayat, Esmaeel

    2014-01-01

    High-energy linacs produce secondary particles such as neutrons (photoneutron production). The neutrons have the important role during treatment with high energy photons in terms of protection and dose escalation. In this work, neutron dose equivalents of 18 MV Varian and Elekta accelerators are measured by thermoluminescent dosimeter (TLD) 600 and TLD700 detectors and compared with the Monte Carlo calculations. For neutron and photon dose discrimination, first TLDs were calibrated separately by gamma and neutron doses. Gamma calibration was carried out in two procedures; by standard 60Co source and by 18 MV linac photon beam. For neutron calibration by 241Am-Be source, irradiations were performed in several different time intervals. The Varian and Elekta linac heads and the phantom were simulated by the MCNPX code (v. 2.5). Neutron dose equivalent was calculated in the central axis, on the phantom surface and depths of 1, 2, 3.3, 4, 5, and 6 cm. The maximum photoneutron dose equivalents which calculated by the MCNPX code were 7.06 and 2.37 mSv.Gy-1 for Varian and Elekta accelerators, respectively, in comparison with 50 and 44 mSv.Gy-1 achieved by TLDs. All the results showed more photoneutron production in Varian accelerator compared to Elekta. According to the results, it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry inside the linac field due to high photon flux, while MCNPX code is an appropriate alternative for studying photoneutron production. PMID:24600167

  10. Neutron dose measurements of Varian and Elekta linacs by TLD600 and TLD700 dosimeters and comparison with MCNP calculations.

    PubMed

    Nedaie, Hassan Ali; Darestani, Hoda; Banaee, Nooshin; Shagholi, Negin; Mohammadi, Kheirollah; Shahvar, Arjang; Bayat, Esmaeel

    2014-01-01

    High-energy linacs produce secondary particles such as neutrons (photoneutron production). The neutrons have the important role during treatment with high energy photons in terms of protection and dose escalation. In this work, neutron dose equivalents of 18 MV Varian and Elekta accelerators are measured by thermoluminescent dosimeter (TLD) 600 and TLD700 detectors and compared with the Monte Carlo calculations. For neutron and photon dose discrimination, first TLDs were calibrated separately by gamma and neutron doses. Gamma calibration was carried out in two procedures; by standard 60Co source and by 18 MV linac photon beam. For neutron calibration by (241)Am-Be source, irradiations were performed in several different time intervals. The Varian and Elekta linac heads and the phantom were simulated by the MCNPX code (v. 2.5). Neutron dose equivalent was calculated in the central axis, on the phantom surface and depths of 1, 2, 3.3, 4, 5, and 6 cm. The maximum photoneutron dose equivalents which calculated by the MCNPX code were 7.06 and 2.37 mSv.Gy(-1) for Varian and Elekta accelerators, respectively, in comparison with 50 and 44 mSv.Gy(-1) achieved by TLDs. All the results showed more photoneutron production in Varian accelerator compared to Elekta. According to the results, it seems that TLD600 and TLD700 pairs are not suitable dosimeters for neutron dosimetry inside the linac field due to high photon flux, while MCNPX code is an appropriate alternative for studying photoneutron production.

  11. Dosimetry of high-energy electron linac produced photoneutrons and the bremsstrahlung gamma-rays using TLD-500 and TLD-700 dosimeter pairs

    NASA Astrophysics Data System (ADS)

    Mukherjee, Bhaskar; Makowski, Dariusz; Simrock, Stefan

    2005-06-01

    The neutron and gamma doses are crucial to interpreting the radiation effects in microelectronic devices operating in a high-energy accelerator environment. This report highlights a method for an accurate estimation of photoneutron and the accompanying bremsstrahlung (gamma) doses produced by a 450 MeV electron linear accelerator (linac) operating in pulsed mode. The principle is based on the analysis of thermoluminescence glow-curves of TLD-500 (Aluminium Oxide) and TLD-700 (Lithium Fluoride) dosimeter pairs. The gamma and fast neutron response of the TLD-500 and TLD-700 dosimeter pairs were calibrated with a 60Co (gamma) and a 241Am-Be (α, n) neutron standard-source, respectively. The Kinetic Energy Released in Materials (kerma) conversion factor for photoneutrons was evaluated by folding the neutron kerma (dose) distribution in 7LiF (the main component of the TLD-700 dosimeter) with the energy spectra of the 241Am-Be (α, n) neutrons and electron accelerator produced photoneutrons. The neutron kerma conversion factors for 241Am-Be neutrons and photoneutrons were calculated to be 2.52×10 -3 and 1.37×10 -3 μGy/a.u. respectively. The bremsstrahlung (gamma) dose conversion factor was evaluated to be 7.32×10 -4 μGy/a.u. The above method has been successfully utilised to assess the photoneutron and bremsstrahlung doses from a 450 MeV electron linac operating at DESY Research Centre in Hamburg, Germany.

  12. Microprocessor controlled portable TLD system

    NASA Technical Reports Server (NTRS)

    Apathy, I.; Deme, S.; Feher, I.

    1996-01-01

    An up-to-date microprocessor controlled thermoluminescence dosemeter (TLD) system for environmental and space dose measurements has been developed. The earlier version of the portable TLD system, Pille, was successfully used on Soviet orbital stations as well as on the US Space Shuttle, and for environmental monitoring. The new portable TLD system, Pille'95, consists of a reader and TL bulb dosemeters, and each dosemeter is provided with an EEPROM chip for automatic identification. The glow curve data are digitised and analysed by the program of the reader. The measured data and the identification number appear on the LED display of the reader. Up to several thousand measured data together with the glow curves can be stored on a removable flash memory card. The whole system is supplied either from built-in rechargeable batteries or from the mains of the space station.

  13. [The application of non-annealing thermoluminescent dosimetry (TLD)].

    PubMed

    Wu, J M; Chen, C S; Lan, R H

    1993-06-01

    Conventional use of Thermoluminescence (TL) in radiation dosimetry is very time-consuming. It requires repeating the procedures of preheating and annealing. In an attempt to simplify these procedures, we conducted an experiment of non-annealing TL dosimetry. This article reports the experiment's results. We adopted Lithium Fluoride (LiF) chip (TLD-100) in polystyrene under the exposure of Co-60, and the result was taken by HAR-SHAW-4000 TL reading system. The TL response was analyzed, including linearity, reproducibility and fading test. Because non-annealing TL response was greatly influenced by residual electron, TLD calibration curves were separated into two parts: (1) high dose region (HDR, 50-1500 cGy); (2) low dose region (LDR, 0-50 cGy). When TL dosimeters were exposed to a single high does (about 500 cGy), the HDR could be reproduced within 3% and fit a good linearity. For LDR, we had to give up the tail of glow curve in the high temperature region. We could then get good linearity and reproducibility. Furthermore, fading of non-annealing was apparently larger than annealing. We could control the fading of non-annealing was apparently larger than annealing. We could control the fading influence within 1% by taking the TL reading one hour after exposure. On the other hand, a combination of photon and electron exposure was also performed by non-annealing TL dosimetry. The results were compatible with Co-60 exposure in the same system.

  14. Comparative study on skin dose measurement using MOSFET and TLD for pediatric patients with acute lymphatic leukemia.

    PubMed

    Al-Mohammed, Huda I; Mahyoub, Fareed H; Moftah, Belal A

    2010-07-01

    The object of this study was to compare the difference of skin dose measured in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using metal oxide semiconductor field-effect transistors (mobile MOSFET dose verification system (TN-RD-70-W) and thermoluminescent dosimeters (TLD-100 chips, Harshaw/ Bicron, OH, USA). Because TLD has been the most-commonly used technique in the skin dose measurement of TBI, the aim of the present study is to prove the benefit of using the mobile MOSFET (metal oxide semiconductor field effect transistor) dosimeter, for entrance dose measurements during the total body irradiation (TBI) over thermoluminescent dosimeters (TLD). The measurements involved 10 pediatric patients ages between 3 and 14 years. Thermoluminescent dosimeters and MOSFET dosimetry were performed at 9 different anatomic sites on each patient. The present results show there is a variation between skin dose measured with MOSFET and TLD in all patients, and for every anatomic site selected, there is no significant difference in the dose delivered using MOSFET as compared to the prescribed dose. However, there is a significant difference for every anatomic site using TLD compared with either the prescribed dose or MOSFET. The results indicate that the dosimeter measurements using the MOSFET gave precise measurements of prescribed dose. However, TLD measurement showed significant increased skin dose of cGy as compared to either prescribed dose or MOSFET group. MOSFET dosimeters provide superior dose accuracy for skin dose measurement in TBI as compared with TLD.

  15. Preliminary Studies of Thermoluminescence Dosimeter (TLD) CaSO4:Dy Synthesis

    NASA Astrophysics Data System (ADS)

    Nuraeni, N.; Iskandar, F.; Waris, A.; Haryanto, F.

    2017-07-01

    Thermoluminescence dosimeter (TLD) CaSO4:Dy was synthesised by coprecipitation. The TLD was observed after radiation exposure to Strontium-90. The thermoluminescence intensity was read using a TLD Reader Harshaw 3500. The thermoluminescent response obtained was 59.29 nC. Then re-annealing was conducted with the temperature varied at 700, 800 and 900 °C. The thermoluminescent intensity obtained at temperatures of 700 °C, 800 °C and 900 °C was 66.12 nC, 169.45 nC, and 552.37 nC respectively. The sensitivity of the TLD increased in response to the re-annealing temperature rise. In addition to observing the thermoluminescence properties, a comparison was made between the TLD obtained from this experiment with an existing TLD in the market. Finally, also the glow-curve characteristics of the TLD were observed.

  16. Type testing the Model 6600 plus automatic TLD reader.

    PubMed

    Velbeck, K J; Luo, L Z; Streetz, K L

    2006-01-01

    The Harshaw Model 6600 Plus is a reader with a capacity for 200 TLD cards or 800 extremity cards. The new unit integrates more functionality, and significantly automates the QC and calibration process compared to the Model 6600. The Model 6600 Plus was tested against the IEC 61066 (1991-2012) procedures using Harshaw TLD-700H and TLD-600H, LiF:Mg,Cu,P based TLD Cards. An overview of the type testing procedures is presented. These include batch homogeneity, detection threshold, reproducibility, linearity, self-irradiation, residue, light effects on dosemeter, light leakage to reader, voltage and frequency, dropping and reader stability. The new TLD reader was found to meet all the IEC criteria by large margins and appears well suited for whole body, extremity and environmental dosimetry applications, with a high degree of dosimetric performance.

  17. SU-E-T-222: Investigation of Pre and Post Irradiation Fading of the TLD100 Thermoluminescence Dosimetry for Photon Beams

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sina, S; Sadeghi, M; Faghihi, R

    2014-06-01

    Purpose: The pre-irradiation and post-irradiation fading of the Thermoluminescense dosimeter signals were investigated in this study. Methods: Two groups of TLD chips with pre-determined ECC values were used in this study. The two groups were divided into 6 series, each composing of 5 TLD chips.The first group was used for pre-irradiation fading. 5 TLDs were exposed to a known amount of radiation from Cs-137 source, and were read out the next day. After seven days, the other 5 TLDs were exposed to the same amount of radiation and were read out after a day. The other series of 5 TLDsmore » were also exposed after 7,19,28, 59, and 90 days, and were read out a day after irradiation. The loss in TLD signal were obtained for all the above cases. The second group, was used for postirradiation fading. All the TLDs of this group were exposed to a known amount of radiation from Cs-137 source. The 6 series composed of 5 TLDs were read out after 1,7,19,28,59, and 90 days. The above-mentioned procedures for obtaining pre-irradiation, and post-irradiation fading were performed for three storage temperatures (25°C, 4°C, and −18°C). Results: According to the results obtained in this study, in case of pre-irradiation fading study, the signal losses after 90 days are 12%, 24%, and 17% for 25°C, 4°C, and −18°C respectively. In case of post-irradiation fading study, the sensitivity losses after 90 days are 25%, 216%, and 20% for 25°C, 4°C, and −18°C respectively. Conclusion: The results indicate that the optimized time between exposing and reading out, and also the optimized time between annealing and exposing is 1 day.The reduction of Storage temperature will reduce the post-irradiation fading, While temperature reduction does not have any effect on pre-irradiation fading.« less

  18. In vivo TLD dose measurements in catheter-based high-dose-rate brachytherapy.

    PubMed

    Adlienė, Diana; Jakštas, Karolis; Urbonavičius, Benas Gabrielis

    2015-07-01

    Routine in vivo dosimetry is well established in external beam radiotherapy; however, it is restricted mainly to detection of gross errors in high-dose-rate (HDR) brachytherapy due to complicated measurements in the field of steep dose gradients in the vicinity of radioactive source and high uncertainties. The results of in vivo dose measurements using TLD 100 mini rods and TLD 'pin worms' in catheter-based HDR brachytherapy are provided in this paper alongside with their comparison with corresponding dose values obtained using calculation algorithm of the treatment planning system. Possibility to perform independent verification of treatment delivery in HDR brachytherapy using TLDs is discussed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Seismic Vibration Control of Elevated Water Tank by TLD and Validation of Full-Scale TLD Model through Real-Time-Hybrid-Testing

    NASA Astrophysics Data System (ADS)

    Roy, A.; Staino, A.; (D Ghosh, A.; Basu, B.; Chatterjee, S.

    2016-09-01

    Elevated water tanks (EWTs), being top-heavy structures, are highly vulnerable to earthquake forces, and several have experienced damage/failure in past seismic events. However, as these are critical facilities whose continued performance in the post-earthquake scenario is of vital concern, it is significant to investigate their seismic vibration control using reliable and cost-effective passive dampers such as the Tuned Liquid Damper (TLD). Here, this aspect is studied for flexible EWT structures, such as those with annular shaft supports. The criterion of tuning the sloshing frequency of the TLD to the structural frequency necessitates dimensions of the TLD larger than those hitherto examined in literature. Hence the nonlinear model of the TLD based on established shallow water wave theory is verified for large container size by employing Real-Time-Hybrid-Testing (RTHT). Simulation studies are further carried out on a realistic example of a flexible EWT structure with TLDs. Results indicate that the TLD can be applied very effectively for the seismic vibration mitigation of EWTs.

  20. Thermoluminescence Dosimetry (TLD) and its Application in Medical Physics

    NASA Astrophysics Data System (ADS)

    Azorín Nieto, Juan

    2004-09-01

    Radiation dosimetry is fundamental in Medical Physics, involving patients and phantom dosimetry. In both cases thermoluminescence dosimetry (TLD) is the most appropriate technique for measuring the absorbed dose. In this paper thermoluminescence phenomenon as well as the use of TLD in radiodiagnosis and radiotherapy for in vivo or in phantom measurements is discussed. Some results of measurements made in radiotherapy and radiodiagnosis using home made LiF:Mg,Cu,P+PTFE TLD are presented.

  1. A method to minimise the fading effects of LiF:Mg,Ti (TLD-600 and TLD-700) using a pre-heat technique.

    PubMed

    Lee, YoungJu; Won, Yuho; Kang, Kidoo

    2015-04-01

    Passive integrating dosemeters [thermoluminescent dosimeter (TLD) and optically stimulated luminescence (OSL)] are the only legally permitted individual dosemeters for occupational external radiation exposure monitoring in Korea. Also its maximum issuing cycle does not exceed 3 months, and the Korean regulations require personal dosemeters for official assessment of external radiation exposure to be issued by an approved or rather an accredited dosimetry service according to ISO/IEC 17025. KHNP (Korea Hydro & Nuclear Power, LTD), a unique operating company of nuclear power plants (NPPs) in Korea, currently has a plan to extend a TLD issuing cycle from 1 to 3 months under the authors' fading error criteria, ±10%. The authors have performed a feasibility study that minimises post-irradiation fading effects within their maximum reading cycle employing pre-heating technique. They repeatedly performed irradiation/reading a bare TLD chip to determine optimum pre-heating conditions by analysing each glow curve. The optimum reading conditions within the maximum reading cycle of 3 months were decided: a pre-heating temperature of 165°C, a pre-heating time of 9 s, a heating rate of 25°C s(-1), a reading temperature of 300°C and an acquisition time of 10 s. The fading result of TLD-600 and TLD-700 carried by newly developed time temperature profile (TTP) showed a much smaller fading effect than that of current TTP. The result showed that the fading error due to a developed TTP resulted in a ∼5% signal loss, whereas a current TTP caused a ∼15% loss. The authors also carried out a legal performance test on newly developed TTP to confirm its possibility as an official dosemeter. The legal performance tests that applied the developed TTP satisfied the criteria for all the test categories. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  2. Dosimetry for Small Fields in Stereotactic Radiosurgery Using Gafchromic MD-V2-55 Film, TLD-100 and Alanine Dosimeters

    PubMed Central

    Massillon-JL, Guerda; Cueva-Prócel, Diego; Díaz-Aguirre, Porfirio; Rodríguez-Ponce, Miguel; Herrera-Martínez, Flor

    2013-01-01

    This work investigated the suitability of passive dosimeters for reference dosimetry in small fields with acceptable accuracy. Absorbed dose to water rate was determined in nine small radiation fields with diameters between 4 and 35 mm in a Leksell Gamma Knife (LGK) and a modified linear accelerator (linac) for stereotactic radiosurgery treatments. Measurements were made using Gafchromic film (MD-V2-55), alanine and thermoluminescent (TLD-100) dosimeters and compared with conventional dosimetry systems. Detectors were calibrated in terms of absorbed dose to water in 60Co gamma-ray and 6 MV x-ray reference (10×10 cm2) fields using an ionization chamber calibrated at a standards laboratory. Absorbed dose to water rate computed with MD-V2-55 was higher than that obtained with the others dosimeters, possibly due to a smaller volume averaging effect. Ratio between the dose-rates determined with each dosimeter and those obtained with the film was evaluated for both treatment modalities. For the LGK, the ratio decreased as the dosimeter size increased and remained constant for collimator diameters larger than 8 mm. The same behaviour was observed for the linac and the ratio increased with field size, independent of the dosimeter used. These behaviours could be explained as an averaging volume effect due to dose gradient and lack of electronic equilibrium. Evaluation of the output factors for the LGK collimators indicated that, even when agreement was observed between Monte Carlo simulation and measurements with different dosimeters, this does not warrant that the absorbed dose to water rate in the field was properly known and thus, investigation of the reference dosimetry should be an important issue. These results indicated that alanine dosimeter provides a high degree of accuracy but cannot be used in fields smaller than 20 mm diameter. Gafchromic film can be considered as a suitable methodology for reference dosimetry. TLD dosimeters are not appropriate in fields

  3. The Origins of Specificity in the Microcin-Processing Protease TldD/E.

    PubMed

    Ghilarov, Dmitry; Serebryakova, Marina; Stevenson, Clare E M; Hearnshaw, Stephen J; Volkov, Dmitry S; Maxwell, Anthony; Lawson, David M; Severinov, Konstantin

    2017-10-03

    TldD and TldE proteins are involved in the biosynthesis of microcin B17 (MccB17), an Escherichia coli thiazole/oxazole-modified peptide toxin targeting DNA gyrase. Using a combination of biochemical and crystallographic methods we show that E. coli TldD and TldE interact to form a heterodimeric metalloprotease. TldD/E cleaves the N-terminal leader sequence from the modified MccB17 precursor peptide, to yield mature antibiotic, while it has no effect on the unmodified peptide. Both proteins are essential for the activity; however, only the TldD subunit forms a novel metal-containing active site within the hollow core of the heterodimer. Peptide substrates are bound in a sequence-independent manner through β sheet interactions with TldD and are likely cleaved via a thermolysin-type mechanism. We suggest that TldD/E acts as a "molecular pencil sharpener": unfolded polypeptides are fed through a narrow channel into the active site and processively truncated through the cleavage of short peptides from the N-terminal end. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  4. Thermoluminescent dosimeters (TLD) quality assurance network in the Czech Republic.

    PubMed

    Kroutilķková, Daniela; Novotný, Josef; Judas, Libor

    2003-02-01

    The Czech thermoluminescent dosimeters (TLD) quality assurance network was established in 1997. Its aim is to pursue a regular independent quality audit in Czech radiotherapy centres and to support state supervision. The audit is realised via mailed TL dosimetry. The TLD system consists of encapsulated LiF:Mg,Ti powder (type MT-N) read with Harshaw manual reader model 4000. Basic mode of the TLD audit covers measurements under reference conditions, specifically beam calibration checks for all clinically used photon and electron beams. Advanced mode consists of measurements under both reference and non-reference conditions using a solid multipurpose phantom ('Leuven phantom') for photon beams. The radiotherapy centres are instructed to deliver to the TLD on central beam axis absorbed dose of 2 Gy calculated with their treatment planning system for a particular treatment set-up. The TLD measured doses are compared with the calculated ones. Deviations of +/-3% are considered acceptable for both basic and advanced mode of the audit. There are 34 radiotherapy centres in the Czech Republic. They undergo the basic mode of the TLD audit regularly every 2 years. If a centre shows a deviation outside the acceptance level, it is audited more often. Presently, most of the checked beams comply with the acceptance level. The advanced TLD audit has been implemented as a pilot study for the present. The results were mostly within the acceptance limit for the measurements on-axis, whereas for off-axis points they fell beyond the limit more frequently, especially for set-ups with inhomogeneities, oblique incidence and wedges. The results prove the importance of the national TLD quality assurance network. It has contributed to the improvement of clinical dosimetry in the Czech Republic. In addition, it helps the regulatory authority to monitor effectively and regularly radiotherapy centres.

  5. Kinetic modelling of the optically stimulated conversion of peaks 5a and 5 to peak 4 in LiF:Mg,Ti (TLD-100).

    PubMed

    Weizman, Y; Horowitz, Y S; Oster, L

    2002-01-01

    The TC/LC conversion model for peaks 4, 5a and 5 in LiF:Mg,Ti (TLD-100) has been studied by solution of the coupled differential equations describing the charge carrier traffic following optical stimulation. Aspects of the model investigated were (i) the two-component exponential decay of the composite peak 5 TL intensity following the bleach, (ii) the role of retrapping during bleaching, (iii) the hole nature of peak 4 and (iv) the conversion of peak 5a traps to peak 4 traps. The high conversion efficiency is naturally explained due to the absence of conduction band competitive mechanisms in the optical ionisation of the electron in the e-h occupied structure corresponding to peak 5a and thereby leading to the hole-only occupied TC/LC leading to peak 4.

  6. Final report of AFRIMETS.M.M-S6: supplementary comparison of 100 mg, 100 g 500 g, 1 kg and 5 kg stainless steel mass standards

    NASA Astrophysics Data System (ADS)

    Mautjana, R. T.; Molefe, P. T.; Mayindu, N. F.; Armah, M. N.; Ramasawmy, V.; Albasini, G. L.; Matali, S.; Richmond, H.; Rusimbi, V.; Kiwanuka, J.; Mutale, D. M.; Mutsimba, F.

    2018-01-01

    This report summarizes the results of AFRIMETS.M.M-S6 mass standards comparison conducted between eleven participating laboratories/countries. Two sets of five weights with nominal values 100 mg, 100 g, 500 g, 1 kg and 5 kg were used as the traveling standards. These nominal values were decided from the needs of participating laboratories submitted to the pilot laboratory through a questionnaire and agreed upon by all participants. The traveling standards were hand carried between laboratories starting from February 2014 and were received from the last participants in October 2014. The programme was coordinated by National Metrology Institute of South Africa (NMISA), who provided the travelling standards and reference values for the comparison. The corrections to the BIPM as-maintained mass unit [5] have insignificant influence on the results of this comparison. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  7. Skin dose measurements using MOSFET and TLD for head and neck patients treated with tomotherapy.

    PubMed

    Kinhikar, Rajesh A; Murthy, Vedang; Goel, Vineeta; Tambe, Chandrashekar M; Dhote, Dipak S; Deshpande, Deepak D

    2009-09-01

    The purpose of this work was to estimate skin dose for the patients treated with tomotherapy using metal oxide semiconductor field-effect transistors (MOSFETs) and thermoluminescent dosimeters (TLDs). In vivo measurements were performed for two head and neck patients treated with tomotherapy and compared to TLD measurements. The measurements were subsequently carried out for five days to estimate the inter-fraction deviations in MOSFET measurements. The variation between skin dose measured with MOSFET and TLD for first patient was 2.2%. Similarly, the variation of 2.3% was observed between skin dose measured with MOSFET and TLD for second patient. The tomotherapy treatment planning system overestimated the skin dose as much as by 10-12% when compared to both MOSFET and TLD. However, the MOSFET measured patient skin doses also had good reproducibility, with inter-fraction deviations ranging from 1% to 1.4%. MOSFETs may be used as a viable dosimeter for measuring skin dose in areas where the treatment planning system may not be accurate.

  8. The response of a thermoluminescent dosimeter to low energy protons in the range 30-100 keV.

    PubMed

    Chu, T C; Lin, S Y; Hsu, C C; Li, J P

    2001-11-01

    This study demonstrates the thermoluminescence (TL) response of CaF2:Tm (commercial name TLD-300) to 30-100 keV protons which were generated by means of a Cockcroft-Walton accelerator. The phenomenon in which the total thermoluminescent output from CaF2:Tm (TLD-300) decreases with proton energy from 30 to 100 keV (with increase of LET) can be interpreted by the track structure theory (TST). The analysis of the glow peaks: P2 (131 degrees C), P3 (153.5 degrees C) and P6 (259 degrees C), of TLD-300 show the oscillatory decreasing phenomenon as a function of incident proton energy, which can be interpreted with the TST and the oscillatory emission of electrons in a thermoluminescent dosimeter (TLD) that is caused by resonant or quasi-resonant charge transfer in ion-atom interactions in this TLD-300.

  9. Positional glow curve simulation for thermoluminescent detector (TLD) system design

    NASA Astrophysics Data System (ADS)

    Branch, C. J.; Kearfott, K. J.

    1999-02-01

    Multi- and thin element dosimeters, variable heating rate schemes, and glow-curve analysis have been employed to improve environmental and personnel dosimetry using thermoluminescent detectors (TLDs). Detailed analysis of the effects of errors and optimization of techniques would be highly desirable. However, an understanding of the relationship between TL light production, light attenuation, and precise heating schemes is made difficult because of experimental challenges involved in measuring positional TL light production and temperature variations as a function of time. This work reports the development of a general-purpose computer code, thermoluminescent detector simulator, TLD-SIM, to simulate the heating of any TLD type using a variety of conventional and experimental heating methods including pulsed focused or unfocused lasers with Gaussian or uniform cross sections, planchet, hot gas, hot finger, optical, infrared, or electrical heating. TLD-SIM has been used to study the impact on the TL light production of varying the input parameters which include: detector composition, heat capacity, heat conductivity, physical size, and density; trapped electron density, the frequency factor of oscillation of electrons in the traps, and trap-conduction band potential energy difference; heating scheme source terms and heat transfer boundary conditions; and TL light scatter and attenuation coefficients. Temperature profiles and glow curves as a function of position time, as well as the corresponding temporally and/or spatially integrated glow values, may be plotted while varying any of the input parameters. Examples illustrating TLD system functions, including glow curve variability, will be presented. The flexible capabilities of TLD-SIM promises to enable improved TLD system design.

  10. Type Testing of Model 7200 Automatic TLD Reader.

    PubMed

    Malek Mohammadi, M; Hosseini Pooya, S M

    2017-04-20

    The type testing of measuring devices is one of the most important parts of a quality management system in a personal dosimetry services program. In this study, based upon the International Electrotechnical Commission (IEC) 62387 criteria, a reader-testing program was performed for a home-made personal thermoluminescent dosimetry (TLD) reader. The stability of the reader, the effects of light exposure, temperature and fluctuations of primary power supply on TLD read-outs as the main parameters were investigated in this program. Moreover, this study assesses some important criteria of dosimetry system including the non-linearity of response, reusability, after effect and overload that may include significant contribution in the performance of a reader. The results showed that the TLD reader met all requirements of the IEC for the reader tests by a large margin. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method.

    PubMed

    HosseiniAliabadi, S J; Hosseini Pooya, S M; Afarideh, H; Mianji, F

    2015-06-01

    The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. This system can be utilized in large scale environmental monitoring with a higher accuracy.

  12. Improvement of Accuracy in Environmental Dosimetry by TLD Cards Using Three-dimensional Calibration Method

    PubMed Central

    HosseiniAliabadi, S. J.; Hosseini Pooya, S. M.; Afarideh, H.; Mianji, F.

    2015-01-01

    Introduction The angular dependency of response for TLD cards may cause deviation from its true value on the results of environmental dosimetry, since TLDs may be exposed to radiation at different angles of incidence from the surrounding area. Objective A 3D setting of TLD cards has been calibrated isotropically in a standard radiation field to evaluate the improvement of the accuracy of measurement for environmental dosimetry. Method Three personal TLD cards were rectangularly placed in a cylindrical holder, and calibrated using 1D and 3D calibration methods. Then, the dosimeter has been used simultaneously with a reference instrument in a real radiation field measuring the accumulated dose within a time interval. Result The results show that the accuracy of measurement has been improved by 6.5% using 3D calibration factor in comparison with that of normal 1D calibration method. Conclusion This system can be utilized in large scale environmental monitoring with a higher accuracy. PMID:26157729

  13. Localised and delocalised optically induced conversion of composite glow peak 5 in LiF:Mg,Ti (TLD-100) to glow peak 4 as a function of postirradiation annealing temperature.

    PubMed

    Horowitz, Y S; Einav, Y; Biderman, S; Oster, L

    2002-01-01

    The composite structure of glow peak 5 in LiF:Mg,Ti (TLD-100) has been investigated using optical bleaching by 310 nm (4 eV) light. The glow peak conversion efficiency of peak 5a (Tm = 187 degrees C) to peak 4 traps is very high at a value of 3+/-0.5 (1 SD) whereas the glow peak conversion efficiency of peak 5 (Tm = 205 degrees C) to peak 4 traps is 0.0026+/-0.0012 (1 SD). The high conversion efficiency of peak 5a to peak 4 arises from direct optical ionisation of the electron in the electron-hole pair. leaving behind a singly-trapped hole (peak 4), a direct mechanism, relatively free of competitive mechanisms. Optical ionisation of the 'singly-trapped' electron (peak 5), however, can lead to peak 4 only via multi-stage mechanisms involving charge carrier transport in the valence and conduction bands, a mechanism subject to competitive processes. The conduction/valence band competitive processes lead to the factor of one thousand decrease in the conversion efficiency of peak 5 compared to peak 5a.

  14. A LiF and BeO TLD based microdosimeter for space radiation risk assessment of astronauts

    NASA Astrophysics Data System (ADS)

    Mukherjee, B.

    2018-06-01

    The ratio of thermoluminescence glow curve area of BeO and LiF dosimeters was found to be proportional to average LET and quality factor (Q) of impinging mixed radiations. Using this phenomenon and widely available Thermoluminescence Dosimeter TLD-700 (7LiF: Mg,Ti) and BeO (Thermolux 995) chips a TLD-Microdosimeter (LiBe-14) emulating a much larger gas-filled Tissue Equivalent Proportional Counter (TEPC) was developed. The TEPC is an essential device of space radiation dosimetry widely used by international space agencies. The LiBe-14 is capable of assessing the LETTissue (5–300 keV/μm), quality factor Q (1–30) and associated dose equivalent H (0.1–1000 mSv) of any mixed radiation fields of interest, including space radiations predominant in Low Earth Orbit (LEO) environment. The TLD microdosimeter was calibrated using the secondary radiation fields produced by bombarding a 25 cm × 25 cm × 35 cm polystyrene phantom with 81, 119, 150, 177, 201 and 231 MeV protons from a Proton Therapy Medical Cyclotron. The TLD pair (BeO/LiF) was attached to the TEPC and placed lateral to the proton beam. The characteristics of space radiation inside the spacecraft are complex. Hence, personal dosimetry of astronauts in the space habitat is performed using "multi-element" dosimeters made of different types of TLD and CR-39 plastic nuclear track detector (PNTD). The TLD and PNTD are used to assess the sparsely (low LET) and densely (high LET) ionising radiation component respectively. This report elucidates the feasibility of LiBe-14 microdosimeter for the estimation of overall dose equivalent and "risk of exposure induced death" (REID) of astronauts working in LEO space stations.

  15. Radiological properties of plastics and TLD materials its application in radiation dosimetry

    NASA Astrophysics Data System (ADS)

    Jabaseelan Samuel, E. James; Srinivasan, K.; Poopathi, V.

    2017-05-01

    In the current study, we evaluated the tissue equivalency of nine different commonly used thermoluminescence compounds and six plastic materials over the photon energy range of 15 KeV to 20 MeV. Our result confirmed that the ratio of number of electrons per gram, electron density of the entire TLD compounds and plastic materials to ICRU-44 soft tissue was lesser than unity, except in the case of polypropylene plastics. The effective atomic number ratio of all the plastic materials was also <1 excluding Poly-vinyl-chloride, and for TLD lithium borate material, it was <1 others which showed the deviation with respect to photon energy. Mass attenuation coefficient (µ/ϼ), mass absorption coefficient (µen/ρ) was calculated and the results are discussed in this paper.

  16. Evaluation of The Combined Effects of Hyperthermia, Cobalt-60 Gamma Rays and IUdR on Cultured Glioblastoma Spheroid Cells and Dosimetry Using TLD-100

    PubMed Central

    Neshasteh-Riz, Ali; Rahdani, Rozhin; Mostaar, Ahmad

    2014-01-01

    Objective In radiation treatment, the irradiation which is effective enough to control the tumors far exceeds normal-tissues tolerance. Thus to avoid such unfavourable outcomes, some methods sensitizing the tumor cells to radiation are used. Iododeoxyuridine (IUdR) is a halogenated thymidine analogue that known to be effective as a radiosensitizer in human cancer therapy. Improving the potential efficacy of radiation therapy after combining to hyperthermia depends on the magnitude of the differential sensitization of the hyperthermic effects or on the differential cytotoxicity of the radiation effects on the tumor cells. In this study, we evaluated the combined effects of IUdR, hyperthermia and gamma rays of 60Co on human glioblastoma spheroids culture. Materials and Methods In this experimental study,the cultured spheroids with 100µm diameter were treated by 1 µM IUdR, 43°C hyperthermia for an hour and 2 Gy gamma rays, respectively. The DNA damages induced in cells were compared using alkaline comet assay method, and dosimetry was then performed by TLD-100. Comet scores were calculated as mean ± standard error of mean (SEM) using one-way ANOVA. Results Comparison of DNA damages induced by IUdR and hyperthermia + gamma treatment showed 2.67- and 1.92-fold enhancement, respectively, as compared to the damages induced by radiation alone or radiation combined IUdR. Dosimetry results showed the accurate dose delivered to cells. Conclusion Analysis of the comet tail moments of spheroids showed that the radiation treatments combined with hyperthermia and IUdR caused significant radiosensitization when compared to related results of irradiation alone or of irradiation with IUdR. These results suggest a potential clinical advantage of combining radiation with hyperthermia and indicate effectiveness of hyperthermia treatment in inducing cytotoxicity of tumor cells. PMID:24611138

  17. Comparison of TLD calibration methods for  192Ir dosimetry

    PubMed Central

    Butler, Duncan J.; Wilfert, Lisa; Ebert, Martin A.; Todd, Stephen P.; Hayton, Anna J.M.; Kron, Tomas

    2013-01-01

    For the purpose of dose measurement using a high‐dose rate  192Ir source, four methods of thermoluminescent dosimeter (TLD) calibration were investigated. Three of the four calibration methods used the  192Ir source. Dwell times were calculated to deliver 1 Gy to the TLDs irradiated either in air or water. Dwell time calculations were confirmed by direct measurement using an ionization chamber. The fourth method of calibration used 6 MV photons from a medical linear accelerator, and an energy correction factor was applied to account for the difference in sensitivity of the TLDs in  192Ir and 6 M V. The results of the four TLD calibration methods are presented in terms of the results of a brachytherapy audit where seven Australian centers irradiated three sets of TLDs in a water phantom. The results were in agreement within estimated uncertainties when the TLDs were calibrated with the  192Ir source. Calibrating TLDs in a phantom similar to that used for the audit proved to be the most practical method and provided the greatest confidence in measured dose. When calibrated using 6 MV photons, the TLD results were consistently higher than the  192Ir−calibrated TLDs, suggesting this method does not fully correct for the response of the TLDs when irradiated in the audit phantom. PACS number: 87 PMID:23318392

  18. Towards in vivo TLD dosimetry in mammography.

    PubMed

    Warren-Forward, H M; Duggan, L

    2004-05-01

    While phantoms are used for quality control assessment of the mammography unit, in vivo dose measurements are necessary to account for the variation in size and composition of the female breast. The use of thermoluminescent dosimeters (TLDs) in mammography has been limited due to TLD visibility. The aim of this current investigation was to access the suitability of a paper-thin LiF:Mg,Cu,P TLD (GR-200F) for in vivo dosimetric mammography measurements. The visibility of GR-200F has been directly compared with LiF:Mg,Cu,P TLDs (GR-200A) using a number of commercially available phantoms. The phantoms of thickness 2-5 cm were imaged over the range of tube potentials (24-28 kVp) used clinically. Both types of TLD were placed on the surface of the phantoms allowing assessment of visibility, entrance surface dose (ESD) and field homogeneity. In vivo assessment of ESD and visibility was also carried out on a volunteer undergoing a routine mammography examination. The positions of the GR-200F TLDs were not identified either on the image of the Leeds TOR(MAM) phantom or the patient mammograms. The average ESD for the Leeds phantom was 8.8 mGy, while the patient ESD was 13 mGy. It is now possible to perform in vivo measurements with the potential of increasing the accuracy of the doses measured for women that do not conform to a standard breast thickness or density.

  19. Comparison of doses calculated by the Monte Carlo method and measured by LiF TLD in the buildup region for a 60Co photon beam.

    PubMed

    Budanec, M; Knezević, Z; Bokulić, T; Mrcela, I; Vrtar, M; Vekić, B; Kusić, Z

    2008-12-01

    This work studied the percent depth doses of (60)Co photon beams in the buildup region of a plastic phantom by LiF TLD measurements and by Monte Carlo calculations. An agreement within +/-1.5% was found between PDDs measured by TLD and calculated by the Monte Carlo method with the TLD in a plastic phantom. The dose in the plastic phantom was scored in voxels, with thickness scaled by physical and electron density. PDDs calculated by electron density scaling showed a better match with PDD(TLD)(MC); the difference is within +/-1.5% in the buildup region for square and rectangular field sizes.

  20. A 100g Mass Comparator with an Improved Readability and Measuring Environment

    NASA Astrophysics Data System (ADS)

    Ueki, Masaaki; Sun, Jian-Xin; Ueda, Kazunaga

    In order to achieve higher accuracy of the mass standard in the mass range equal to or less than 100g, it is necessary for a mass comparator in the range to have a relative sensitivity of the order of 1×10-9. For this purpose, a 111g capacity fully-automatic mass comparator has been renovated so that its readability is improved from 1 to 0.1µg. The mass comparator is also installed in an air-tight chamber originally developed by the NMIJ, so that it can be kept in stable environment, especially in the air of constant density. With these renovations, standard deviation of the mass comparisons is reduced and uncertainty of the air buoyancy corrections is lessened. This paper reports the features of the improved 100g mass comparator, the empirical method to evaluate its performance and the obtained results. As a result, the standard deviations of the mass difference measurements have been greatly improved to 0.22µg in the average with the chamber closed, compared with 0.97µg with the one open. The linearity of the comparator has been also verified by the mass difference measurements of weights at the six masses of 10, 20, 30, 50, 70 and 100g, and it confirms that the non-linearity errors of the comparator are within 0.28µg, showing good measuring performance.

  1. Nonlinear multimodal model for TLD of irregular tank geometry and small fluid depth

    NASA Astrophysics Data System (ADS)

    Love, J. S.; Tait, M. J.

    2013-11-01

    Tuned liquid dampers (TLDs) utilize sloshing fluid to absorb and dissipate structural vibrational energy. TLDs of irregular or complex tank geometry may be required in practice to avoid tank interference with fixed structural or mechanical components. The literature offers few analytical models to predict the response of this type of TLD, particularly when the fluid depth is small. In this paper, a multimodal model is developed utilizing a Boussinesq-type modal theory which is valid for small TLD fluid depths. The Bateman-Luke variational principle is employed to develop a system of coupled nonlinear ordinary differential equations which describe the fluid response when the tank is subjected to base excitation. Energy dissipation is incorporated into the model from the inclusion of damping screens. The fluid model is used to describe the response of a 2D structure-TLD system when the structure is subjected to external loading and the TLD tank geometry is irregular.

  2. TLD extrapolation for skin dose determination in vivo.

    PubMed

    Kron, T; Butson, M; Hunt, F; Denham, J

    1996-11-01

    Prediction of skin reactions requires knowledge of the dose at various depths in the human skin. Using thermoluminescence dosimeters of three different thicknesses, the dose can be extrapolated to the surface and interpolated between the different depths. A TLD holder was designed for these TLD extrapolation measurements on patients during treatment which allowed measurements of entrance and exit skin dose with a day to day variability of +/-7% (S.D. of mean reading). In a pilot study on 18 patients undergoing breast irradiation, it was found that the angle of incidence of the radiation beam is the most significant factor influencing skin entrance dose. In most of these measurements the beam exit dose contributed 50% more to the surface dose than the entrance dose.

  3. Using 100G Network Technology in Support of Petascale Science

    NASA Technical Reports Server (NTRS)

    Gary, James P.

    2011-01-01

    NASA in collaboration with a number of partners conducted a set of individual experiments and demonstrations during SC 10 that collectively were titled "Using 100G Network Technology in Support of Petascale Science". The partners included the iCAIR, Internet2, LAC, MAX, National LambdaRail (NLR), NOAA and SCinet Research Sandbox (SRS) as well as the vendors Ciena, Cisco, ColorChip, cPacket, Extreme Networks, Fusion-io, HP and Panduit who most generously allowed some of their leading edge 40G/100G optical transport, Ethernet switch and Internet Protocol router equipment and file server technologies to be involved. The experiments and demonstrations featured different vendor-provided 40G/100G network technology solutions for full-duplex 40G and 100G LAN data flows across SRS-deployed single-node fiber-pairs among the Exhibit Booths of NASA, the National Center for Data lining, NOAA and the SCinet Network Operations Center, as well as between the NASA Exhibit Booth in New Orleans and the Starlight Communications Exchange facility in Chicago across special SC 10- only 80- and 100-Gbps wide area network links provisioned respectively by the NLR and Internet2, then on to GSFC across a 40-Gbps link. provisioned by the Mid-Atlantic Crossroads. The networks and vendor equipment were load-stressed by sets of NASA/GSFC High End Computer Network Team-built, relatively inexpensive, net-test-workstations that are capable of demonstrating greater than 100Gbps uni-directional nuttcp-enabled memory-to-memory data transfers, greater than 80-Gbps aggregate--bidirectional memory-to-memory data transfers, and near 40-Gbps uni-directional disk-to-disk file copying. This paper will summarize the background context, key accomplishments and some significances of these experiments and demonstrations.

  4. Comparison of the calculated absorbed dose using the Cadplan™ treatment planning software and Tld-100 measurements in an Alderson-Rando phantom for a bronchogenic treatment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gutiérrez Castillo, J. G., E-mail: jggc59@hotmail.com; Álvarez Romero, J. T., E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx; Calderón, A. Torres, E-mail: trinidad.alvarez@inin.gob.mx, E-mail: fisarmandotorres@gmail.com, E-mail: victor.tovar@inin.gob.mx

    2014-11-07

    To verify the accuracy of the absorbed doses D calculated by a TPS Cadplan for a bronchogenic treatment (in an Alderson-Rando phantom) are chosen ten points with the following D's and localizations. Point 1, posterior position on the left edge with 136.4 Gy. Points: 2, 3 and 4 in the left lung with 104.9, 104.3 and 105.8 Gy, respectively; points 5 and 6 at the mediastinum with 192.4 and 173.5 Gy; points 7, 8 and 9 in the right lung with 105.8, 104.2 and 104.7 Gy, and 10 at posterior position on right edge with 143.7 Gy. IAEA type capsulesmore » with TLD 100 powder are placed, planned and irradiated. The evaluation of the absorbed dose is carried out a curve of calibration for the LiF response (nC) {sup vs} {sup DW}, to several cavity theories. The traceability for the DW is obtained with a secondary standard calibrated at the NRC (Canada). The dosimetric properties for the materials considered are determined from the Hounsfield numbers reported by the TPS. The stopping power ratios are calculated for nominal spectrum to 6 MV photons. The percent variations among the planned and determined D in all the cases they are < ± 3%.« less

  5. The use of LiF (TLD‐100) as an out‐of‐field dosimeter

    PubMed Central

    Price, Michael; Followill, David; Mourtada, Firas; Salehpour, Mohammad

    2007-01-01

    The commonly used thermoluminescent dosimeter TLD‐100 (Harshaw Chemical Company, Solon, OH) responds not only to photons and electrons, but also to neutrons that are produced during high‐energy therapies. As a result, TLD‐100 measurements outside of the treatment field are suspect when high‐energy radiation is used. Although alternatives such as TLD‐700 do not respond to neutrons, specialty dosimeters of this kind are expensive and are not routinely used in most clinics. In the current study, we examined the accuracy of TLD‐100 in measuring the out‐of‐field photon dose as a function of treatment energy. To determine the accuracy of TLD‐100 as compared with TLD‐700, TLD‐100 was irradiated outside of the treatment field by medical accelerators operated at 6, 10, 15, and 18 MV. In an effort to eliminate the response of TLD‐100 to neutrons, TLD capsules were encased in varying thicknesses of cadmium foil (0.25 – 0.75 mm) before being irradiated at 18 MV. The out‐of‐field TLD‐100 was found to be accurate at 6 MV and 10 MV, but to be substantially over‐responsive at 15 MV and 18 MV (by up to 1063% relative to TLD‐700). By wrapping the TLD‐100 in up to 0.75 mm of cadmium, it was possible to drastically reduce (down to 39% on average) the over‐response of the TLD‐100; however, total removal of the over‐responsiveness was not possible. Although TLD‐100 is well suited for measuring out‐of‐field dose at energies as high as 10 MV, at higher energies (15 MV or greater), this dosimeter over‐responds substantially and should not be used. Although encasing the TLD in cadmium minimized over‐response to a degree, the reduction was not sufficient to make TLD‐100 viable for measuring out‐of‐field dose at high treatment energies. PACS numbers: 87.52.‐g, 87.53.‐j, 87.53.‐Dq

  6. Analysis and recent advances in gamma heating measurements in MINERVE facility by using TLD and OSLD techniques

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amharrak, H.; Di Salvo, J.; Lyoussi, A.

    2011-07-01

    The objective of this study is to develop nuclear heating measurement methods in Zero Power experimental reactors. This paper presents the analysis of Thermo-Luminescent Detector (TLD) and Optically Stimulated Luminescent Detectors (OSLD) experiments in the UO{sub 2} core of the MINERVE research reactor at the CEA Cadarache. The experimental sources of uncertainties on the gamma dose have been reduced by improving the conditions, as well as the repeatability, of the calibration step for each individual TLD. The interpretation of these measurements needs to take into account calculation of cavity correction factors, related to calibration and irradiation configurations, as well asmore » neutron corrections calculations. These calculations are based on Monte Carlo simulations of neutron-gamma and gamma-electron transport coupled particles. TLD and OSLD are positioned inside aluminum pillboxes. The comparison between calculated and measured integral gamma-ray absorbed doses using TLD, shows that calculation slightly overestimates the measurement with a C/E value equal to 1.05 {+-} 5.3 % (k = 2). By using OSLD, the calculation slightly underestimates the measurement with a C/E value equal to 0.96 {+-} 7.0% (k = 2. (authors)« less

  7. NOTE: Monte Carlo simulation of correction factors for IAEA TLD holders

    NASA Astrophysics Data System (ADS)

    Hultqvist, Martha; Fernández-Varea, José M.; Izewska, Joanna

    2010-03-01

    The IAEA standard thermoluminescent dosimeter (TLD) holder has been developed for the IAEA/WHO TLD postal dose program for audits of high-energy photon beams, and it is also employed by the ESTRO-QUALity assurance network (EQUAL) and several national TLD audit networks. Factors correcting for the influence of the holder on the TL signal under reference conditions have been calculated in the present work from Monte Carlo simulations with the PENELOPE code for 60Co γ-rays and 4, 6, 10, 15, 18 and 25 MV photon beams. The simulation results are around 0.2% smaller than measured factors reported in the literature, but well within the combined standard uncertainties. The present study supports the use of the experimentally obtained holder correction factors in the determination of the absorbed dose to water from the TL readings; the factors calculated by means of Monte Carlo simulations may be adopted for the cases where there are no measured data.

  8. Development of a TLD mailed system for remote dosimetry audit for (192)Ir HDR and PDR sources.

    PubMed

    Roué, Amélie; Venselaar, Jack L M; Ferreira, Ivaldo H; Bridier, André; Van Dam, Jan

    2007-04-01

    In the framework of an ESTRO ESQUIRE project, the BRAPHYQS Physics Network and the EQUAL-ESTRO laboratory have developed a procedure for checking the absorbed dose to water in the vicinity of HDR or PDR sources using a mailed TLD system. The methodology and the materials used in the procedure are based on the existing EQUAL-ESTRO external radiotherapy dose checks. A phantom for TLD postal dose assurance service, adapted to accept catheters from different HDR afterloaders, has been developed. The phantom consists of three PMMA tubes supporting catheters placed at 120 degrees around a central TLD holder. A study on the use of LiF powder type DTL 937 (Philitech) has been performed in order to establish the TLD calibration in dose-to-water at a given distance from (192)Ir source, as well as to determine all correction factors to convert the TLD reading into absorbed dose to water. The dosimetric audit is based on the comparison between the dose to water measured with the TL dosimeter and the dose calculated by the clinical TPS. Results of the audits are classified in four different levels depending on the ratio of the measured dose to the stated dose. The total uncertainty budget in the measurement of the absorbed dose to water using TLD near an (192)Ir HDR source, including TLD reading, correction factors and TLD calibration coefficient, is determined as 3.27% (1s). To validate the procedures, the external audit was first tested among the members of the BRAPHYQS Network. Since November 2004, the test has been made available for use by all European brachytherapy centres. To date, 11 centres have participated in the checks and the results obtained are very encouraging. Nevertheless, one error detected has shown the usefulness of this audit. A method of absorbed dose to water determination in the vicinity of an (192)Ir brachytherapy source was developed for the purpose of a mailed TL dosimetry system. The accuracy of the procedure was determined. This method allows a

  9. Measurement of dose given by Co-60 in radiotherapy with TLD-500

    NASA Astrophysics Data System (ADS)

    Tanır, Güneş; Cengiz, Ferhat; Hicabi Bölükdemir, M.

    2012-04-01

    The uses of dosimeters based on optically stimulated luminescence technique have become widespread in clinical applications. In the present study, the dose values given by Cobalt-60 radiotherapy machine were measured with optically stimulated luminescence (OSL) technique using TLD-500 and compared with those of commonly used ionization chamber dosimeter system. The percentage depth dose (DD%) values and graphs were formed. OSL system with TLD-500 can be reliably used as medical and personal dosimeter.

  10. Image-guided method for TLD-based in vivo rectal dose verification with endorectal balloon in proton therapy for prostate cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hsi, Wen C.; Fagundes, Marcio; Zeidan, Omar

    Purpose: To present a practical image-guided method to position an endorectal balloon that improves in vivo thermoluminiscent dosimeter (TLD) measurements of rectal doses in proton therapy for prostate cancer. Methods: TLDs were combined with endorectal balloons to measure dose at the anterior rectal wall during daily proton treatment delivery. Radiopaque metallic markers were employed as surrogates for balloon position reproducibility in rotation and translation. The markers were utilized to guide the balloon orientation during daily treatment employing orthogonal x-ray image-guided patient positioning. TLDs were placed at the 12 o'clock position on the anterior balloon surface at the midprostatic plane. Markersmore » were placed at the 3 and 9 o'clock positions on the balloon to align it with respect to the planned orientation. The balloon rotation along its stem axis, referred to as roll, causes TLD displacement along the anterior-posterior direction. The magnitude of TLD displacement is revealed by the separation distance between markers at opposite sides of the balloon on sagittal x-ray images. Results: A total of 81 in vivo TLD measurements were performed on six patients. Eighty-three percent of all measurements (65 TLD readings) were within +5% and -10% of the planning dose with a mean of -2.1% and a standard deviation of 3.5%. Examination of marker positions with in-room x-ray images of measured doses between -10% and -20% of the planned dose revealed a strong correlation between balloon roll and TLD displacement posteriorly from the planned position. The magnitude of the roll was confirmed by separations of 10-20 mm between the markers which could be corrected by manually adjusting the balloon position and verified by a repeat x-ray image prior to proton delivery. This approach could properly correct the balloon roll, resulting in TLD positioning within 2 mm along the anterior-posterior direction. Conclusions: Our results show that image-guided TLD

  11. Image-guided method for TLD-based in vivo rectal dose verification with endorectal balloon in proton therapy for prostate cancer.

    PubMed

    Hsi, Wen C; Fagundes, Marcio; Zeidan, Omar; Hug, Eugen; Schreuder, Niek

    2013-05-01

    To present a practical image-guided method to position an endorectal balloon that improves in vivo thermoluminiscent dosimeter (TLD) measurements of rectal doses in proton therapy for prostate cancer. TLDs were combined with endorectal balloons to measure dose at the anterior rectal wall during daily proton treatment delivery. Radiopaque metallic markers were employed as surrogates for balloon position reproducibility in rotation and translation. The markers were utilized to guide the balloon orientation during daily treatment employing orthogonal x-ray image-guided patient positioning. TLDs were placed at the 12 o'clock position on the anterior balloon surface at the midprostatic plane. Markers were placed at the 3 and 9 o'clock positions on the balloon to align it with respect to the planned orientation. The balloon rotation along its stem axis, referred to as roll, causes TLD displacement along the anterior-posterior direction. The magnitude of TLD displacement is revealed by the separation distance between markers at opposite sides of the balloon on sagittal x-ray images. A total of 81 in vivo TLD measurements were performed on six patients. Eighty-three percent of all measurements (65 TLD readings) were within +5% and -10% of the planning dose with a mean of -2.1% and a standard deviation of 3.5%. Examination of marker positions with in-room x-ray images of measured doses between -10% and -20% of the planned dose revealed a strong correlation between balloon roll and TLD displacement posteriorly from the planned position. The magnitude of the roll was confirmed by separations of 10-20 mm between the markers which could be corrected by manually adjusting the balloon position and verified by a repeat x-ray image prior to proton delivery. This approach could properly correct the balloon roll, resulting in TLD positioning within 2 mm along the anterior-posterior direction. Our results show that image-guided TLD-based in vivo dosimetry for rectal dose verification

  12. Experimental investigation of the 100 keV X-ray dose response of the high-temperature thermoluminescence in LiF:Mg,Ti (TLD-100): theoretical interpretation using the unified interaction model.

    PubMed

    Livingstone, J; Horowitz, Y S; Oster, L; Datz, H; Lerch, M; Rosenfeld, A; Horowitz, A

    2010-03-01

    The dose response of LiF:Mg,Ti (TLD-100) chips was measured from 1 to 50,000 Gy using 100 keV X rays at the European Synchroton Radiation Facility. Glow curves were deconvoluted into component glow peaks using a computerised glow curve deconvolution (CGCD) code based on first-order kinetics. The normalised dose response, f(D), of glow peaks 4 and 5 and 5b (the major components of composite peak 5), as well as peaks 7 and 8 (two of the major components of the high-temperature thermoluminescence (HTTL) at high levels of dose) was separately determined and theoretically interpreted using the unified interaction model (UNIM). The UNIM is a nine-parameter model encompassing both the irradiation/absorption stage and the thermally induced relaxation/recombination stage with an admixture of both localised and delocalised recombination mechanisms. The effects of radiation damage are included in the present modelling via the exponential removal of luminescent centres (LCs) at high dose levels. The main features of the experimentally measured dose response are: (i) increase in f(D)(max) with glow peak temperature, (ii) increase in D(max) (the dose level at which f(D)(max) occurs) with increasing glow peak temperature, and (iii) decreased effects of radiation damage with increasing glow peak temperature. The UNIM interpretation of this behaviour requires both strongly decreasing values of ks (the relative contribution of localised recombination) as a function of glow peak temperature and, as well, significantly different values of the dose-filling constants of the trapping centre (TC) and LC for peaks 7 and 8 than those used for peaks 4 and 5. This suggests that different TC/LC configurations are responsible for HTTL. The relative intensity of peak 5a (a low-temperature satellite of peak 5 arising from localised recombination) was found to significantly increase at higher dose levels due to preferential electron and hole population of the trapping/recombination complex giving

  13. A methodology for TLD postal dosimetry audit of high-energy radiotherapy photon beams in non-reference conditions.

    PubMed

    Izewska, Joanna; Georg, Dietmar; Bera, Pranabes; Thwaites, David; Arib, Mehenna; Saravi, Margarita; Sergieva, Katia; Li, Kaibao; Yip, Fernando Garcia; Mahant, Ashok Kumar; Bulski, Wojciech

    2007-07-01

    A strategy for national TLD audit programmes has been developed by the International Atomic Energy Agency (IAEA). It involves progression through three sequential dosimetry audit steps. The first step audits are for the beam output in reference conditions for high-energy photon beams. The second step audits are for the dose in reference and non-reference conditions on the beam axis for photon and electron beams. The third step audits involve measurements of the dose in reference, and non-reference conditions off-axis for open and wedged symmetric and asymmetric fields for photon beams. Through a co-ordinated research project the IAEA developed the methodology to extend the scope of national TLD auditing activities to more complex audit measurements for regular fields. Based on the IAEA standard TLD holder for high-energy photon beams, a TLD holder was developed with horizontal arm to enable measurements 5cm off the central axis. Basic correction factors were determined for the holder in the energy range between Co-60 and 25MV photon beams. New procedures were developed for the TLD irradiation in hospitals. The off-axis measurement methodology for photon beams was tested in a multi-national pilot study. The statistical distribution of dosimetric parameters (off-axis ratios for open and wedge beam profiles, output factors, wedge transmission factors) checked in 146 measurements was 0.999+/-0.012. The methodology of TLD audits in non-reference conditions with a modified IAEA TLD holder has been shown to be feasible.

  14. Linoleic acid-menthyl ester reduces the secretion of apolipoprotein B100 in HepG2 cells.

    PubMed

    Inoue, Nao; Yamano, Naomi; Sakata, Kotaro; Arao, Keisuke; Kobayashi, Takashi; Nagao, Toshihiro; Shimada, Yuji; Nagao, Koji; Yanagita, Teruyoshi

    2009-01-01

    The effect of linoleic acid-menthyl ester (LAME) on lipid metabolism were assessed in HepG2 cells. It is well known that high level of apolipoprotein (apo) B100 in the serum is risk for atherosclerosis. Although linoleic acid (LA) treatment and LA plus L-mentol treatment increased apo B100 secretion, LAME treatment significantly decreased apo B100 secretion in HepG2 cells compared with control medium. The hypolipidemic effect of LAME was attributable to the suppression of triglyceride synthesis in HepG2 cells. It is also known that the risk of coronary heart disease is negatively related to the concentration of serum apo A-1. In the present study, LAME treatment increased apo A-1 secretion as compared with LA treatment in HepG2 cells. These results suggest that mentyl-esterification of fatty acids may be beneficial in anti-atherogenic dietary therapy.

  15. TLD postal dose intercomparison for megavoltage units in Poland.

    PubMed

    Izewska, J; Gajewski, R; Gwiazdowska, B; Kania, M; Rostkowska, J

    1995-08-01

    The aim of the TLD pilot study was to investigate and to reduce the uncertainties involved in the measurements of absorbed dose and to improve the consistency in dose determination in the regional radiotherapy centres in Poland. The intercomparison was organized by the SSDL. It covered absorbed dose measurements under reference conditions for Co-60, high energy X-rays and electron beams. LiF powder type MT-N was used for the irradiations and read with the Harshaw TLD reader model 2000B/2000C. The TLD system was set up and an analysis of the factors influencing the accuracy of absorbed dose measurements with TL-detectors was performed to evaluate and minimize the measurement uncertainty. A fading not exceeding 2% in 12 weeks was found. The relative energy correction factor did not exceed 3% for X-rays in the range 4-15 MV, and 4% for electron beams between 6 and 20 MeV. A total of 34 beams was checked. Deviation of +/- 3.5% stated and evaluated dose was considered acceptable for photons and +/- 5% for electron beams. The results for Co-60, high energy X-rays and electron beams showed that there were two, three and no centres, respectively, beyond acceptance levels. The sources of errors for all deviations out of this range were thoroughly investigated, discussed and corrected, however two deviations remained unexplained. The pilot study resulted in an improvement of the accuracy and consistency of dosimetry in Poland.

  16. SU-E-T-118: Dose Verification for Accuboost Applicators Using TLD, Ion Chamber and Gafchromic Film Measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chisela, W; Yao, R; Dorbu, G

    Purpose: To verify dose delivered with HDR Accuboost applicators using TLD, ion chamber and Gafchromic film measurements and to examine applicator leakage. Methods: A microSelectron HDR unit was used to deliver a dose of 50cGy to the mid-plane of a 62mm thick solid water phantom using dwell times from Monte Carlo pre-calculated nomograms for a 60mm, 70mm Round and 60mm Skin-Dose Optimized (SDO) applicators respectively. GafChromic EBT3+ film was embedded in the phantom midplane horizontally to measure dose distribution. Absolute dose was also measured with TLDs and an ADCL calibrated parallel-plate ion chamber placed in the film plane at fieldmore » center for each applicator. The film was calibrated using 6MV x-ray beam. TLDs were calibrated in a Cs-137 source at UW-Madison calibration laboratory. Radiation leakage through the tungsten alloy shell was measured with a film wrapped around outside surface of a 60mm Round applicator. Results: Measured maximum doses at field center are consistently lower than predicated by 5.8% for TLD, 8.8% for ion chamber, and 2.6% for EBT3+ film on average, with measurement uncertainties of 2.2%, 0.3%, and 2.9% for TLD, chamber, film respectively. The total standard uncertainties for ion chamber and Gafchromic film measurement are 4.9% and 4.6% respectively[1]. The area defined by the applicator aperture was covered by 80% of maximum dose for 62mm compression thickness. When 100cGy is delivered to mid-plane with a 60mm Round applicator, surface dose ranges from 60cGy to a maximum of 145cGy, which occurs at source entrance to the applicator. Conclusion: Measured doses by all three techniques are consistently lower than predicted in our measurements. For a compression thickness of 62 mm, the field size defined by the applicator is only covered by 80% of prescribed dose. Radiation leakage of up to 145cGy was found at the source entrance of applicators.« less

  17. TLD assessment of mouse dosimetry during microCT imaging

    PubMed Central

    Figueroa, Said Daibes; Winkelmann, Christopher T.; Miller, William H.; Volkert, Wynn A.; Hoffman, Timothy J.

    2008-01-01

    Advances in laboratory animal imaging have provided new resources for noninvasive biomedical research. Among these technologies is microcomputed tomography (microCT) which is widely used to obtain high resolution anatomic images of small animals. Because microCT utilizes ionizing radiation for image formation, radiation exposure during imaging is a concern. The objective of this study was to quantify the radiation dose delivered during a standard microCT scan. Radiation dose was measured using thermoluminescent dosimeters (TLDs), which were irradiated employing an 80 kVp x-ray source, with 0.5 mm Al filtration and a total of 54 mA s for a full 360 deg rotation of the unit. The TLD data were validated using a 3.2 cm3 CT ion chamber probe. TLD results showed a single microCT scan air kerma of 78.0±5.0 mGy when using a poly(methylmethacrylate) (PMMA) anesthesia support module and an air kerma of 92.0±6.0 mGy without the use of the anesthesia module. The validation CT ion chamber study provided a measured radiation air kerma of 81.0±4.0 mGy and 97.0±5.0 mGy with and without the PMMA anesthesia module, respectively. Internal TLD analysis demonstrated an average mouse organ radiation absorbed dose of 76.0±5.0 mGy. The author’s results have defined x-ray exposure for a routine microCT study which must be taken into consideration when performing serial molecular imaging studies involving the microCT imaging modality. PMID:18841837

  18. The Rockwell SR-100G reactor turboelectric space power system

    NASA Technical Reports Server (NTRS)

    Anderson, R. V.

    1985-01-01

    During FY 1982 and 1983, Rockwell International performed system and subsystem studies for space reactor power systems. These studies drew on the expertise gained from the design and flight of the SNAP-10A space nuclear reactor system. These studies, performed for the SP-100 Program, culminated in the selection of a reactor-turboelectric (gas Brayton) system for the SP-100 application; this system is called the SR-100G. This paper describes the features of the system and provides references where more detailed information can be obtained.

  19. The 1998 Australian external beam radiotherapy survey and IAEA/WHO TLD postal dose quality audit.

    PubMed

    Huntley, R; Izewska, J

    2000-03-01

    The results of an updated Australian survey of external beam radiotherapy centres are presented. Most of the centres provided most of the requested information. The relative caseloads of various linear accelerator photon and electron beams have not changed significantly since the previous survey in 1995. The mean age of Australian LINACs is 7.1 years and that of other radiotherapy machines is 14.7 years. Every Australian radiotherapy centre participated in a special run of the IAEA/WHO TLD postal dose quality audit program, which was provided for Australian centres by the IAEA and WHO in May 1998. The dose quoted by the centres was in nearly every case within 1.5% of the dose assessed by the IAEA. This is within the combined standard uncertainty of the IAEA TLD service (1.8%). The results confirm the accuracy and precision of radiotherapy dosimetry in Australia and the adequate dissemination of the Australian standards from ARL (now ARPANSA) to the centres. The Australian standards have recently been shown to agree with those of other countries to within 0.25% by comparison with the BIPM.

  20. A Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams.

    PubMed

    Mobit, P N; Nahum, A E; Mayles, P

    1998-08-01

    A Monte Carlo simulation of the quality dependence of different TL materials, in the form of discs 3.61 mm in diameter and 0.9 mm thick, in radiotherapy photon beams relative to 60Co gamma-rays has been performed. The beam qualities ranged from 50 kV to 25 MV x-rays. The TL materials were: CaF2, CaSO4, LiF and Li2B4O7. The effects of the dopants on energy deposition in the TL material have also been determined for the highly sensitive LiF:Mg:Cu:P (TLD-100H) and for CaF2:Mn. It was found that there was a significant difference in the quality dependence factor derived from Monte Carlo simulations between LiF and LiF:Mg:Cu:P but not between CaF2 and CaF2:Mn. The quality dependence factors for Li2B4O7 varied from 0.990 +/- 0.008 (1 sd) for 25 MV x-rays to 0.940 +/- 0.009 (1 sd) for 50 kV x-rays relative to 60Co gamma-rays; Monte Carlo simulations were also performed for Li2B4O7 in megavoltage electron beams. For CaF2, the quality dependence factor varied from 0.927 +/- 0.008 (1 sd) for 25 MV x-rays to 10.561 +/- 0.008 (1 sd) for 50 kV x-rays. The figure for CaSO4 ranged from 0.943 +/- 0.008 (1 sd) for 25 MV x-rays to 9.010 +/- 0.008 (1 sd) for 50 kV x-rays. The quality dependence factor for CaF2 increases by up to 5% with depth and by up to 15% with field size for the kilovoltage x-ray beams. For LiF-TLD, however, there was no significant dependence on the field size or depth of irradiation in the kilovoltage energy range.

  1. A fast and sensitive TLD method for measurement of energy and homogeneity of electron beams using transmitted radiation through lead.

    PubMed

    Pradhan, A S; Quast, U; Sharma, P K

    1994-09-01

    A simple and fast, but sensitive TLD method for the measurement of energy and homogeneity of therapeutically used electron beams has been developed and tested. This method is based on the fact that when small thicknesses of high-Z absorbers such as lead are interposed in the high-energy electron beams, the transmitted radiation increases with the energy of the electron beams. Consequently, the ratio of readouts of TLDS held on the two sides of a lead plate varied sharply (by factor of 70) with a change in energy of the electron beam from 5 MeV to 18 MeV, offering a very sensitive method for the measurement of the energy of electron beams. By using the ratio of TL readouts of two types of TLD ribbon with widely different sensitivities, LiF TLD-700 ribbons on the upstream side and highly sensitive CaF2:Dy TLD-200 ribbons on the downstream side, an electron energy discrimination of better than +/- 0.1 MeV could be achieved. The homogeneity of the electron beam energy and the absorbed dose was measured by using a jig in which the TLDS were held in the desired array on both sides of a 4 mm thick lead plate. The method takes minimal beam time and makes it possible to carry out measurements for the audit of the quality of electron beams as well as for intercomparison of beams by mail.

  2. Determination of quality parameters from statistical analysis of routine TLD dosimetry data.

    PubMed

    German, U; Weinstein, M; Pelled, O

    2006-01-01

    Following the as low as reasonably achievable (ALARA) practice, there is a need to measure very low doses, of the same order of magnitude as the natural background, and the limits of detection of the dosimetry systems. The different contributions of the background signals to the total zero dose reading of thermoluminescence dosemeter (TLD) cards were analysed by using the common basic definitions of statistical indicators: the critical level (L(C)), the detection limit (L(D)) and the determination limit (L(Q)). These key statistical parameters for the system operated at NRC-Negev were quantified, based on the history of readings of the calibration cards in use. The electronic noise seems to play a minor role, but the reading of the Teflon coating (without the presence of a TLD crystal) gave a significant contribution.

  3. An approach to an analysis of the energy response of LiF-TLD to high energy electrons.

    PubMed

    Shiragai, A

    1977-05-01

    Responses of LiF-TLD to high energy electrons relative to 60Co gamma-rays were investigated experimentally and theoretically. The Burlin et al. theory, its modified version by Almond and McCray and the Holt et al. semi-empirical theory were examined in comparison with each experiment. An approximate approach to theoretical analysis of energy response of LiF-TLD was attempted and compared with some experimental results.

  4. Evaluation of the Sensitivity and Signal Response of the DT-702 LiF:Mg,Cu,P TLD

    DTIC Science & Technology

    2007-06-27

    energy stored from the radiation interactions that occurs prior to the TLD being read. Electrons can absorb additional energy from sources other...thermoluminescent dosimetry , annealing is the 24 process used to clear any radiation exposure information from a TLD , preparing it for reuse...702 four-chip TLDs were obtained from the Naval Dosimetry Center (NDC), Bethesda, MD. Each card was tested by Thermo prior to delivery to NDC to

  5. Variations in photon energy spectra of a 6 MV beam and their impact on TLD response

    PubMed Central

    Scarboro, Sarah B.; Followill, David S.; Howell, Rebecca M.; Kry, Stephen F.

    2011-01-01

    Purpose: Measurement of the absorbed dose from radiotherapy beams is an essential component of providing safe and reproducible treatment. For an energy-dependent dosimeter such as thermoluminescent dosimeters (TLDs), it is generally assumed that the energy spectrum is constant throughout the treatment field and is unperturbed by field size, depth, field modulation, or heterogeneities. However, this does not reflect reality and introduces error into clinical dose measurements. The purpose of this study was to evaluate the variability in the energy spectrum of a Varian 6 MV beam and to evaluate the impact of these variations in photon energy spectra on the response of a common energy-dependent dosimeter, TLD. Methods: Using Monte Carlo methods, we calculated variations in the photon energy spectra of a 6 MV beam as a result of variations of treatment parameters, including field size, measurement location, the presence of heterogeneities, and field modulation. The impact of these spectral variations on the response of the TLD is largely based on increased photoelectric effect in the dosimeter, and this impact was calculated using Burlin cavity theory. Measurements of the energy response were also made to determine the additional energy response due to all intrinsic and secondary effects. Results: For most in-field measurements, regardless of treatment parameter, the dosimeter response was not significantly affected by the spectral variations (<1% effect). For measurement points outside of the treatment field, where the spectrum is softer, the TLD over-responded by up to 12% due to an increased probability of photoelectric effect in the TLD material as well as inherent ionization density effects that play a role at low photon energies. Conclusions: It is generally acceptable to ignore the impact of variations in the photon spectrum on the measured dose for locations within the treatment field. However, outside the treatment field, the spectra are much softer, and a

  6. Plasminogen activator inhibitor 1 4G/5G and -844G/A variants in idiopathic recurrent pregnancy loss.

    PubMed

    Magdoud, Kalthoum; Herbepin, Viviana G; Touraine, Renaud; Almawi, Wassim Y; Mahjoub, Touhami

    2013-09-01

    Plasminogen activator inhibitor type 1 (PAI-1) regulates fibrinolysis, and the common promoter region variants -675G/A (4G/5G) and -844G/A are associated with increased thrombotic risk. Despite evidence linking altered fibrinolysis with adverse pregnancy events, including idiopathic recurrent pregnancy loss (RPL), the contribution of PAI-1 variants to RPL risk remains controversial. We investigated the association between the PAI-1 -844G/A and 4G/5G (-675G/A) variants with altered risk of RPL. This was a case-control study involving 304 women with confirmed RPL and 371 age- and ethnically matched control women. PAI-1 genotyping was performed by PCR single-specific primer -675 (G/A) and real-time PCR (-844G/A) analysis. Minor allele frequency (MAF) of 4G/5G (P < 0.001), but not -844G/A (P = 0.507), was higher in RPL cases. PAI-1 4G/5G single-nucleotide polymorphism (SNP) was significantly associated with RPL under additive, dominant, and recessive genetic models; no association of -844G/A with RPL was seen irrespective of the genetic model tested. Taking common -844G/5G haplotype as reference (OR = 1.00), multivariate analysis confirmed the association of 4G-containing -844A/4G (P < 0.001) and -844G/4G (P = 0.011) haplotypes with increased RPL risk. 4G/5G, but not -844G/A, PAI-1 variant is associated with an increased risk of RPL. © 2013 John Wiley & Sons Ltd.

  7. SU-E-J-101: Retroactive Calculation of TLD and Film Dose in Anthropomorphic Phantom as Assessment of Updated TPS Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Alkhatib, H; Oves, S

    Purpose: To demonstrate a quick and comprehensive method verifying the accuracy of the updated dose model by recalculating dose distribution in an anthropomorphic phantom with a new version of the TPS and comparing the results to measured values. Methods: CT images and IMRT plan of an RPC anthropomorphic head phantom, previously calculated by Pinnacle 9.0, was re-computed using Pinnacle 9.2 and 9.6. The dosimeters within the phantom include four TLD capsules representing a primary PTV, two TLD capsules representing a secondary PTV, and two TLD capsules representing an organ at risk. Also included were three sheets of Gafchromic film. Performancemore » of the updated TPS version was assessed by recalculating point doses and dose profiles corresponding to TLD and film position respectively and then comparing the results to reported values by the RPC. Results: Comparing calculated doses to reported measured doses from the RPC yielded an average disagreement of 1.48%, 2.04% and 2.10% for versions 9.0, 9.2, 9.6 respectively. Computed doses points all meet the RPC's passing criteria with the exception of the point representing the superior organ at risk in version 9.6. However, qualitative analysis of the recalculated dose profiles showed improved agreement with those of the RPC, especially in the penumbra region. Conclusion: This work has demonstrated the calculation results of Pinnacle 9.2 and 9.6 vs 9.0 version. Additionally, this study illustrates a method for the user to gain confidence upgrade to a newer version of the treatment planning system.« less

  8. Performance testing of the environmental TLD system for the Three Mile Island Nuclear Station.

    PubMed

    Toke, L F; Carson, B H; Baker, G G; McBride, M H; Plato, P A; Miklos, J A

    1984-05-01

    Panasonic UD-801 thermoluminescent dosimeters ( TLDs ) containing two calcium sulfate phosphors were tested under Performance Specification 3.1 established by the American National Standard Institute ( ANSI75 ) and in the U.S. Nuclear Regulatory Commission's Regulatory Guide 4.13 ( NRC77 ). The specific qualifying tests included TLD uniformity, reproducibility, energy dependence and directional dependence. The overall measurement uncertainties and associated confidence levels are within the prescribed guidelines defined in the qualifying requirements for environmental TLDs .

  9. Organ radiation exposure with EOS: GATE simulations versus TLD measurements

    NASA Astrophysics Data System (ADS)

    Clavel, A. H.; Thevenard-Berger, P.; Verdun, F. R.; Létang, J. M.; Darbon, A.

    2016-03-01

    EOS® is an innovative X-ray imaging system allowing the acquisition of two simultaneous images of a patient in the standing position, during the vertical scan of two orthogonal fan beams. This study aimed to compute organs radiation exposure to a patient, in the particular geometry of this system. Two different positions of the patient in the machine were studied, corresponding to postero-anterior plus left lateral projections (PA-LLAT) and antero-posterior plus right lateral projections (AP-RLAT). To achieve this goal, a Monte-Carlo simulation was developed based on a GATE environment. To model the physical properties of the patient, a computational phantom was produced based on computed tomography scan data of an anthropomorphic phantom. The simulations provided several organs doses, which were compared to previously published dose results measured with Thermo Luminescent Detectors (TLD) in the same conditions and with the same phantom. The simulation results showed a good agreement with measured doses at the TLD locations, for both AP-RLAT and PA-LLAT projections. This study also showed that the organ dose assessed only from a sample of locations, rather than considering the whole organ, introduced significant bias, depending on organs and projections.

  10. GW100: Benchmarking G0W0 for Molecular Systems.

    PubMed

    van Setten, Michiel J; Caruso, Fabio; Sharifzadeh, Sahar; Ren, Xinguo; Scheffler, Matthias; Liu, Fang; Lischner, Johannes; Lin, Lin; Deslippe, Jack R; Louie, Steven G; Yang, Chao; Weigend, Florian; Neaton, Jeffrey B; Evers, Ferdinand; Rinke, Patrick

    2015-12-08

    We present the GW100 set. GW100 is a benchmark set of the ionization potentials and electron affinities of 100 molecules computed with the GW method using three independent GW codes and different GW methodologies. The quasi-particle energies of the highest-occupied molecular orbitals (HOMO) and lowest-unoccupied molecular orbitals (LUMO) are calculated for the GW100 set at the G0W0@PBE level using the software packages TURBOMOLE, FHI-aims, and BerkeleyGW. The use of these three codes allows for a quantitative comparison of the type of basis set (plane wave or local orbital) and handling of unoccupied states, the treatment of core and valence electrons (all electron or pseudopotentials), the treatment of the frequency dependence of the self-energy (full frequency or more approximate plasmon-pole models), and the algorithm for solving the quasi-particle equation. Primary results include reference values for future benchmarks, best practices for convergence within a particular approach, and average error bars for the most common approximations.

  11. Efficacy and safety of fluticasone furoate 100 μg once-daily in patients with persistent asthma: a 24-week placebo and active-controlled randomised trial.

    PubMed

    Lötvall, Jan; Bleecker, Eugene R; Busse, William W; O'Byrne, Paul M; Woodcock, Ashley; Kerwin, Edward M; Stone, Sally; Forth, Richard; Jacques, Loretta; Bateman, Eric D

    2014-01-01

    Inhaled corticosteroids (ICSs) improve asthma disease control; once-daily ICS administration may have advantages for patients. Our objective was to assess the efficacy and safety of the novel ICS fluticasone furoate (FF) over 24 weeks versus placebo. This was a 24-week double-blind, double-dummy, placebo- and active-controlled study (NCT01159912) of 343 asthma patients (≥12 years) not controlled by their current ICS. Patients were randomised (1:1:1) to FF100 μg, placebo (both administered once-daily [OD] via ELLIPTA™ dry powder inhaler in the evening) or fluticasone propionate (FP) 250 μg (administered twice-daily (BD) via DISKUS™/ACCUHALER™). Primary endpoint was change from baseline in pre-dose evening forced expiratory volume in 1s (FEV1) at Week 24; change from baseline in % rescue-free 24-h periods was a powered secondary endpoint. Adverse events (AEs) were assessed. FF100 μg OD and FP250 μg BD significantly improved pre-dose evening FEV1 compared with placebo at Week 24 (+146 ml [p = 0.009] and +145 ml [p = 0.011], respectively). Percentage of rescue-free 24-h periods was increased with FF100 μg OD (+14.8%) and FP250 μg BD (+17.9%) compared to placebo (both p < 0.001). On-treatment AEs were reported by 53% (FF100 μg OD), 42% (FP250 μg BD) and 40% (placebo) of patients. On-treatment severe asthma exacerbations were lower with FF100 μg OD (3%) and FP250 μg BD (2%) than placebo (7%). There was significant suppression of urinary cortisol at week 24 with FF100 μg OD (p = 0.030) and FP250 μg BD (p = 0.036) relative to placebo. FF100 μg OD, administered in the evening, achieves significant improvements in lung function and rescue inhaler use over 24 weeks, comparable to FP250 μg BD with similar safety profile. Copyright © 2013 The Authors. Published by Elsevier Ltd.. All rights reserved.

  12. Out-of-field in vivo dosimetry using TLD in SABR for primary kidney cancer involving mixed photon fields.

    PubMed

    Lonski, P; Keehan, S; Siva, S; Pham, D; Franich, R D; Taylor, M L; Kron, T

    2017-05-01

    To assess out-of-field dose using three different variants of LiF thermoluminescence dosimeters (TLD) for ten patients who underwent stereotactic ablative body radiotherapy (SABR) for primary renal cell carcinoma (RCC) and compare with treatment planning system (TPS) dose calculations. Thermoluminescent dosimeter (TLD) measurements were conducted at 20, 30, 40 and 50cm from isocentre on ten patients undergoing SABR for primary RCC. Three types of high-sensitivity LiF:Mg,Cu,P TLD material with different 6 Li/ 7 Li isotope ratios were used. Patient plans were calculated using Eclipse Anisotropic Analytical Algorithm (AAA) for clinical evaluation and recalculated using Pencil Beam Convolution (PBC) algorithm for comparison. Both AAA and PBC showed diminished accuracy for photon doses at increasing distance out-of-field. At 50cm, measured photon dose was 0.3cGy normalised to a 10Gy prescription on average with only small variation across all patients. This is likely due to the leakage component of the out-of-field dose. The 6 Li-enriched TLD materials showed increased signal attributable to additional neutron contribution. LiF:Mg,Cu,P TLD containing 6 Li is sensitive enough to measure out-of-field dose 50cm from isocentre however will over-estimate the photon component of out-of-field dose in high energy treatments due to the presence of thermal neutrons. 7 Li enriched materials which are insensitive to neutrons are therefore required for accurate photon dosimetry. Neutron signal has been shown here to increase with MUs and is higher for patients treated using certain non coplanar beam arrangements. Further work is required to convert this additional neutron signal to dose. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. 8 CFR 100.1 - Introduction.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 8 Aliens and Nationality 1 2010-01-01 2010-01-01 false Introduction. 100.1 Section 100.1 Aliens and Nationality DEPARTMENT OF HOMELAND SECURITY IMMIGRATION REGULATIONS STATEMENT OF ORGANIZATION § 100.1 Introduction. The following components have been delegated authority under the Immigration and...

  14. 100G Ethernet in the wild - first experiences

    NASA Astrophysics Data System (ADS)

    Hoeft, Bruno; Stoy, Robert; Schröder, Frank; Reymund, Aurelie; Niederberger, Ralf; Mextorf, Olaf; Werner, Sabine

    2011-12-01

    A 100 Gigabit Testbed was established in a collaboration of 6 partners. Three industry partners have contributed the fiber infrastructure, the DWDM equipment, as well as the required routers. 447 kilometer was the distance of the wide area testbed established in collaboration with the German NREN DFN between Karlsruhe Institute of Technology and Forschungszentrum Jülich Before starting, DFN assured the quality of the fiber infrastructure, the operation of the DWDM systems at both locations, as well as the connection of the routers to this WAN link with a bandwidth of 100GE. 12*10GE interfaces were available at each site for connecting the local testnodes to the routers. A monitoring and measurement framework was installed for recording the most important IP network performance metrics, among them the One Way Delay (OWD) and its Variation, Packet Loss and Packet Reordering. The delay measurements were conducted between the GPS time synchronized Hades[1]measurement nodes at each location. Additionally all relevant counters at the routers have been recorded using a SNMP based Network Manangement Station and supplemented special command line interface output gathering and parsing scripts. The interfaces statistics were stored in 60 second intervals. The aim of the testbed was to demonstrate a failure-free transmission of one or more IP datastreams over 100GE during the whole period of 4 weeks.This included the evaluation of the 100 Gbit/s optical transmission system, the 100GE interfaces between the routers and the optical system, and the evaluation of a sustained 100GE transmission as well as the evaluation of the use of 100GE in a production like environment. The evaluation included a circulated (in a routing loop) tunable load between 1 and 100 Gbit/s, measurement of transmission quality of TCP and UDP datastreams between the endsystems, measurements of one way latency, a ramping up data transmission from approx. 8 Gbit/s up to 96 Gbit/s.

  15. 42 CFR 100.1 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Applicability. 100.1 Section 100.1 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES VACCINES VACCINE INJURY COMPENSATION § 100.1 Applicability. This part applies to the National Vaccine Injury Compensation Program (VICP) under...

  16. 42 CFR 100.1 - Applicability.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Applicability. 100.1 Section 100.1 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES VACCINES VACCINE INJURY COMPENSATION § 100.1 Applicability. This part applies to the National Vaccine Injury Compensation Program (VICP) under...

  17. 42 CFR 100.1 - Applicability.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Applicability. 100.1 Section 100.1 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES VACCINES VACCINE INJURY COMPENSATION § 100.1 Applicability. This part applies to the National Vaccine Injury Compensation Program (VICP) under...

  18. 42 CFR 100.1 - Applicability.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Applicability. 100.1 Section 100.1 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES VACCINES VACCINE INJURY COMPENSATION § 100.1 Applicability. This part applies to the National Vaccine Injury Compensation Program (VICP) under...

  19. 42 CFR 100.1 - Applicability.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Applicability. 100.1 Section 100.1 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES VACCINES VACCINE INJURY COMPENSATION § 100.1 Applicability. This part applies to the National Vaccine Injury Compensation Program (VICP) under...

  20. Influence of decreased fibrinolytic activity and plasminogen activator inhibitor-1 4G/5G polymorphism on the risk of venous thrombosis.

    PubMed

    Vuckovic, Biljana A; Djeric, Mirjana J; Tomic, Branko V; Djordjevic, Valentina J; Bajkin, Branislav V; Mitic, Gorana P

    2018-01-01

    : Objective of our study is to determine whether decreased fibrinolytic activity or plasminogen activator inhibitor (PAI)-1 4G/5G polymorphism influence the risk of venous thrombosis.Our case-control study included 100 patients with venous thrombosis, and 100 random controls. When patients were compared with random controls, unconditional logistic regression was used to calculate odds ratios (ORs) with 95% confidence intervals (CIs).Decreased fibrinolytic activity yielded a 2.7-fold increase in risk for venous thrombosis than physiological fibrinolytic activity (OR 2.70; 95% CI 1.22-5.98), when comparing patients with random controls. Adjustment for several putative confounders did not change the estimate (OR 3.02; 95% CI 1.26-7.22). Analysis of venous thrombotic risk influenced by PAI-1 genotype, showed no influence of PAI-1 4G/5G gene variant in comparison with 5G/5G genotype (OR 0.57 95% CI; 0.27-1.20).Decreased fibrinolytic activity increased, whereas PAI-1 4G/5G polymorphism did not influence venous thrombosis risk in this study.

  1. Calibration of TLD badges for photons of energy above 6 MeV and dosimetric intricacies in high energy gamma ray fields encountered in nuclear power plants.

    PubMed

    Pradhan, A S; Bakshi, A K

    2002-01-01

    CaSO4:Dy and LiF TLDs do not exhibit photon energy dependence beyond +/-55% for photons in the energy range from 1 MeV to about 7 MeV. However, when sandwiched between metal filters or used in TLD badge holders having metal filters, the response changes for irradiation from high energy photons as compared to that from 60Co gamma rays (generally used for reference calibrations). This effect is about the same for both the lower atomic number TLD (LiF) and higher atomic number TLD (CaSO4:Dy). For TLDs held on the surface of the phantom and irradiated in collimated photon beams, the response of TLDs without any filter or those under the open window of the TLD badge is considerably reduced due to insufficient build-up to high energy photons, whereas for uncollimated radiation fields from power reactors, an over-response is observed. It is observed that the use of inappropriate encapsulation of dosemeters would cause a significant error not only in the estimation of doses due to penetrating radiations but also in the estimation of beta doses in the mixed fields of beta radiation, high energy gamma rays and high energy electrons often encountered in the fields of pressurised heavy water reactors.

  2. 46 CFR 56.01-3 - Power boilers, external piping and appurtenances (Replaces 100.1.1, 100.1.2, 122.1, 132 and 133).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... (Replaces 100.1.1, 100.1.2, 122.1, 132 and 133). 56.01-3 Section 56.01-3 Shipping COAST GUARD, DEPARTMENT OF... boilers, external piping and appurtenances (Replaces 100.1.1, 100.1.2, 122.1, 132 and 133). (a) Power... appurtenances of power boilers, as defined in §§ 100.1.1 and 100.1.2, appearing in the various paragraphs of...

  3. 46 CFR 56.01-3 - Power boilers, external piping and appurtenances (Replaces 100.1.1, 100.1.2, 122.1, 132 and 133).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... (Replaces 100.1.1, 100.1.2, 122.1, 132 and 133). 56.01-3 Section 56.01-3 Shipping COAST GUARD, DEPARTMENT OF... boilers, external piping and appurtenances (Replaces 100.1.1, 100.1.2, 122.1, 132 and 133). (a) Power... appurtenances of power boilers, as defined in §§ 100.1.1 and 100.1.2, appearing in the various paragraphs of...

  4. Calculated and TLD-based absorbed dose estimates for I-131-labeled 3F8 monoclonal antibody in a human neuroblastoma xenograft nude mouse model.

    PubMed

    Ugur, O; Scott, A M; Kostakoglu, L; Hui, T E; Masterson, M E; Febo, R; Sgouros, G; Rosa, E; Mehta, B M; Fisher, D R

    1995-01-01

    Preclinical evaluation of the therapeutic potential of radiolabeled antibodies is commonly performed in a xenografted nude mouse model. To assess therapeutic efficacy it is important to estimate the absorbed dose to the tumor and normal tissues of the nude mouse. The current study was designed to accurately measure radiation does to human neuroblastoma xenografts and normal organs in nude mice treated with I-131-labeled 3F8 monoclonal antibody (MoAb) against disialoganglioside GD2 antigen. Absorbed dose estimates were obtained using two different approaches: (1) measurement with teflon-imbedded CaSO4:Dy mini-thermoluminescent dosimeters (TLDs) and (2) calculations using mouse S-factors. The calculated total dose to tumor one week after i.v. injection of the 50 microCi I-131-3F8 MoAb was 604 cGy. The corresponding decay corrected and not corrected TLD measurements were 109 +/- 9 and 48.7 +/- 3.4 cGy respectively. The calculated to TLD-derived dose ratios for tumor ranged from 6.1 at 24 h to 5.5 at 1 week. The light output fading rate was found to depend upon the tissue type within which the TLDs were implanted. The decay rate in tumor, muscle, subcutaneous tissue and in vitro, were 9.5, 5.0, 3.7 and 0.67% per day, respectively. We have demonstrated that the type of tissue in which the TLD was implanted strongly influenced the in vivo decay of light output. Even with decay correction, a significant discrepancy was observed between MIRD-based calculated and CaSO4:Dy mini-TLD measured absorbed doses. Batch dependence, pH of the tumor or other variables associated with TLDs which are not as yet well known may account for this discrepancy.

  5. 10 CFR 100.1 - Purpose.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Purpose. 100.1 Section 100.1 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) REACTOR SITE CRITERIA § 100.1 Purpose. (a) The purpose of this part is to establish approval requirements for proposed sites for stationary power and testing reactors subject to part 50 or...

  6. External audits of electron beams using mailed TLD dosimetry: preliminary results.

    PubMed

    Gomola, I; Van Dam, J; Isern-Verdum, J; Verstraete, J; Reymen, R; Dutreix, A; Davis, B; Huyskens, D

    2001-02-01

    A feasibility study has been performed to investigate the possibility of using mailed thermoluminescence dosimetry (TLD) for external audits of clinical electron beams in Europe. In the frame of the EC Network Project for Quality Assurance in Radiotherapy, instruction sheets and mailing procedures have been defined for mailed TLD dosimetry using the dedicated holder developed by a panel of experts of the International Atomic Energy Agency (IAEA). Three hundred and thirty electron beam set-ups have been checked in the reference centres and some local centres of the EC Network Project and in addition through the centres participating to the EORTC Radiotherapy Group trial 22922. The mean ratio of measured dose to stated dose is 0.2% and the standard deviation of measured dose to stated dose is 3.2%. In seven beam set-ups, deviations greater than 10% were observed (max. 66%), showing the usefulness of these checks. The results of this feasibility study (instruction sheets, mailing procedures, holder) are presently endorsed by the EQUAL-ESTRO structure in order to offer in the future to all ESTRO members the possibility to request external audits of clinical electron beams.

  7. Development of 100 g Si and 250 g Ge detectors for a dark matter search

    NASA Astrophysics Data System (ADS)

    Brink, P. L.; Cabrera, B.; Chugg, B.; Clarke, R. M.; Davies, A.; Nam, S. W.; Young, B. A.

    1996-05-01

    Over the last two years we have proposed and implemented a new phonon sensing scheme for Cryogenic elementary particle detectors based upon Transition Edge Sensors (TES) operated in the (negative) Electrothermal-feedback (ETF) mode, and utilizing large Al collection pads for the initial phonon absorption. We have also implemented an ionization electrode, in addition to the phonon sensors, to allow the simultaneous measurement of ionization and phonon signals in Si and Ge absorbers. Our progress to date include successfully discriminating between electron and nuclear recoils down to a threshold of 4 keV recoil energy for a 4 g Si detector. Our first 100 g Si detectors have been fabricated, and initial work on Ge detectors indicates that our phonon sensing scheme will also work on large mass Ge absorbers.

  8. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors.

    PubMed

    Karsch, L; Beyreuther, E; Burris-Mog, T; Kraft, S; Richter, C; Zeil, K; Pawelke, J

    2012-05-01

    The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10(11) Gy∕s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the number of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. The dosimeters are dose rate independent up to 4●10(9) Gy∕s within 2% (OSL and TLD) and up to 15●10(9) Gy∕s within 5% (EBT films). The diamond detectors show strong dose rate dependence. TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.

  9. Dose rate dependence for different dosimeters and detectors: TLD, OSL, EBT films, and diamond detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Karsch, L.; Beyreuther, E.; Burris-Mog, T.

    Purpose: The use of laser accelerators in radiation therapy can perhaps increase the low number of proton and ion therapy facilities in some years due to the low investment costs and small size. The laser-based acceleration technology leads to a very high peak dose rate of about 10{sup 11} Gy/s. A first dosimetric task is the evaluation of dose rate dependence of clinical dosimeters and other detectors. Methods: The measurements were done at ELBE, a superconductive linear electron accelerator which generates electron pulses with 5 ps length at 20 MeV. The different dose rates are reached by adjusting the numbermore » of electrons in one beam pulse. Three clinical dosimeters (TLD, OSL, and EBT radiochromic films) were irradiated with four different dose rates and nearly the same dose. A faraday cup, an integrating current transformer, and an ionization chamber were used to control the particle flux on the dosimeters. Furthermore two diamond detectors were tested. Results: The dosimeters are dose rate independent up to 410{sup 9} Gy/s within 2% (OSL and TLD) and up to 1510{sup 9} Gy/s within 5% (EBT films). The diamond detectors show strong dose rate dependence. Conclusions: TLD, OSL dosimeters, and EBT films are suitable for pulsed beams with a very high pulse dose rate like laser accelerated particle beams.« less

  10. A combined TLD/emulsion method of sampling dosimetry applied to Apollo missions

    NASA Technical Reports Server (NTRS)

    Schaefer, H. J.

    1979-01-01

    A system which simplifies the complex monitoring methods used to measure the astronaut's radiation exposure in space is proposed. The excess dose equivalents of trapped protons and secondary neutrons, protons, and alpha particles from local nuclear interactions are determined and a combined thermoluminescent dosimeter (TLD)/nuclear emulsion method which measures the absorbed dose with thermoluminescent dosimeter chips is presented.

  11. Whole-body dose and energy measurements in radiotherapy by a combination of LiF:Mg,Cu,P and LiF:Mg,Ti.

    PubMed

    Hauri, Pascal; Schneider, Uwe

    2018-04-01

    Long-term survivors of cancer who were treated with radiotherapy are at risk of a radiation-induced tumor. Hence, it is important to model the out-of-field dose resulting from a cancer treatment. These models have to be verified with measurements, due to the small size, the high sensitivity to ionizing radiation and the tissue-equivalent composition, LiF thermoluminescence dosimeters (TLD) are well-suited for out-of-field dose measurements. However, the photon energy variation of the stray dose leads to systematic dose errors caused by the variation in response with radiation energy of the TLDs. We present a dosimeter which automatically corrects for the energy variation of the measured photons by combining LiF:Mg,Ti (TLD100) and LiF:Mg,Cu,P (TLD100H) chips. The response with radiation energy of TLD100 and TLD100H compared to 60 Co was taken from the literature. For the measurement, a TLD100H was placed on top of a TLD100 chip. The dose ratio between the TLD100 and TLD100H, combined with the ratio of the response curves was used to determine the mean energy. With the energy, the individual correction factors for TLD100 and TLD100H could be found. The accuracy in determining the in- and out-of-field dose for a nominal beam energy of 6MV using the double-TLD unit was evaluated by an end-to-end measurement. Furthermore, published Monte Carlo (M.C.) simulations of the mean photon energy for brachytherapy sources, stray radiation of a treatment machine and cone beam CT (CBCT) were compared to the measured mean energies. Finally, the photon energy distribution in an Alderson phantom was measured for different treatment techniques applied with a linear accelerator. Additionally, a treatment plan was measured with a cobalt machine combined with an MRI. For external radiotherapy, the presented double-TLD unit showed a relative type A uncertainty in doses of -1%±2% at the two standard deviation level compared to an ionization chamber. The type A uncertainty in dose was in

  12. Evaluation of the Energy Distribution of Unknown Photon Radiation Fields by Interpreting the Responses of Tld's and Modification of Burlin Cavity Theory.

    NASA Astrophysics Data System (ADS)

    Abdulhay, Ibrahim Shakib

    1995-01-01

    The thermoluminescent dosimeter (TLD) response (integrated light output per unit exposure) of a high Z material increases more rapidly with decreasing photon energy and with energy above the pair production threshold than that of lower Z materials. The ratio of the responses obtained when two thermoluminescent dosimeter (TLD) materials are simultaneously exposed to gamma or x-rays could be used to obtain information about the incident photon energies. In addition, the responses are affected by the presence of the material surrounding the dosimeters. Two TLD's, LiF and CaSO_4, with respective effective atomic number of 8.2 and 15.3, have been chosen to be sandwiched between different absorber materials (Al, Cu, and Pb) and irradiated at selected distances from gamma radiation sources. The photon energies used in this investigation were 60 keV, 142 keV, 662 keV, 1.25 MeV, and 6.129 MeV. Fit equations of the responses of the dosimeters to different energies have been obtained and used to evaluate the energy distributions of unknown ionizing radiation fields. In addition, the electron mass attenuation coefficient beta used in Burlin and Burlin-Horowitz Cavity Theory has been modified to produce better agreement with experimental data at low photon energies and at high energies.

  13. Nonuniform Irradiation of the Canine Intestine. 2. Dosimetry

    DTIC Science & Technology

    1990-01-01

    irradiation is accurate assessment In vivo dosimetry was done using Harshaw (Solon, Ohio) TLD - 100 lith- of the injury after either accidental or... vivo TLD dosimetry system allowed measure- 5 and 6. The dose was determined from the median TLD ment of the °Co dose deposited in the canine small...provide replicate measurements. Two separate dosimetry tubes were deveoped (Fig. 1). The first contained 30 TLD cap- doses (1). Nevertheless, current

  14. S100A8/A9 (Calprotectin) Negatively Regulates G2/M Cell Cycle Progression and Growth of Squamous Cell Carcinoma

    PubMed Central

    Khammanivong, Ali; Wang, Chengxing; Sorenson, Brent S.; Ross, Karen F.; Herzberg, Mark C.

    2013-01-01

    Malignant transformation results in abnormal cell cycle regulation and uncontrolled growth in head and neck squamous cell carcinoma (HNSCC) and other cancers. S100A8/A9 (calprotectin) is a calcium-binding heterodimeric protein complex implicated in cell cycle regulation, but the specific mechanism and role in cell cycle control and carcinoma growth are not well understood. In HNSCC, S100A8/A9 is downregulated at both mRNA and protein levels. We now report that downregulation of S100A8/A9 correlates strongly with a loss of cell cycle control and increased growth of carcinoma cells. To show its role in carcinogenesis in an in vitro model, S100A8/A9 was stably expressed in an S100A8/A9-negative human carcinoma cell line (KB cells, HeLa-like). S100A8/A9 expression increases PP2A phosphatase activity and p-Chk1 (Ser345) phosphorylation, which appears to signal inhibitory phosphorylation of mitotic p-Cdc25C (Ser216) and p-Cdc2 (Thr14/Tyr15) to inactivate the G2/M Cdc2/cyclin B1 complex. Cyclin B1 expression then downregulates and the cell cycle arrests at the G2/M checkpoint, reducing cell division. As expected, S100A8/A9-expressing cells show both decreased anchorage-dependent and -independent growth and mitotic progression. Using shRNA, silencing of S100A8/A9 expression in the TR146 human HNSCC cell line increases growth and survival and reduces Cdc2 inhibitory phosphorylation at Thr14/Tyr15. The level of S100A8/A9 endogenous expression correlates strongly with the reduced p-Cdc2 (Thr14/Tyr14) level in HNSCC cell lines, SCC-58, OSCC-3 and UMSCC-17B. S100A8/A9-mediated control of the G2/M cell cycle checkpoint is, therefore, a likely suppressive mechanism in human squamous cell carcinomas and may suggest new therapeutic approaches. PMID:23874958

  15. MicroRNA-99a and 100 mediated upregulation of FOXA1 in bladder cancer

    PubMed Central

    Drayton, Ross M.; Peter, Stefan; Myers, Katie; Miah, Saiful; Dudziec, Ewa; Bryant, Helen E.; Catto, James W. F.

    2014-01-01

    Urothelial cell carcinoma of the bladder (UCC) is a common disease often characterized by FGFR3 dysregulation. Whilst upregulation of this oncogene occurs most frequently in low-grade non-invasive tumors, recent data reveal increased FGFR3 expression characterizes a common sub-type of invasive UCC sharing molecular similarities with breast cancer. These similarities include upregulation of the FOXA1 transcription factor and reduced expression of microRNAs-99a/100. We have previously identified direct regulation of FGFR3 by these two microRNAs and now search for further targets. Using a microarray meta-database we find potential FOXA1 regulation by microRNAs-99a/100. We confirm direct targeting of the FOXA1 3′UTR by microRNAs-99a/100 and also potential indirect regulation through microRNA-485-5p/SOX5/JUN-D/FOXL1 and microRNA-486/FOXO1a. In 292 benign and malignant urothelial samples, we find an inverse correlation between the expression of FOXA1 and microRNAs-99a/100 (r=−0.33 to −0.43, p<0.05). As for FGFR3 in UCC, tumors with high FOXA1 expression have lower rates of progression than those with low expression (Log rank p=0.009). Using global gene expression and CpG methylation profiling we find genotypic consequences of FOXA1 upregulation in UCC. Genetic changes are associated with regional hypomethylation, occur near FOXA1 binding sites, and mirror gene expression changes previously reported in FGFR3 mutant-UCC. These include gene silencing through aberrant hypermethylation (e.g. IGFBP3) and affect genes characterizing breast cancer sub-types (e.g. ERBB2). In conclusion, we have identified microRNAs-99a/100 mediate a direct relationship between FGFR3 and FOXA1 and potentially facilitate cross talk between these pathways in UCC. PMID:25071007

  16. MicroRNA-99a and 100 mediated upregulation of FOXA1 in bladder cancer.

    PubMed

    Drayton, Ross M; Peter, Stefan; Myers, Katie; Miah, Saiful; Dudziec, Ewa; Bryant, Helen E; Catto, James W F

    2014-08-15

    Urothelial cell carcinoma of the bladder (UCC) is a common disease often characterized by FGFR3 dysregulation. Whilst upregulation of this oncogene occurs most frequently in low-grade non-invasive tumors, recent data reveal increased FGFR3 expression characterizes a common sub-type of invasive UCC sharing molecular similarities with breast cancer. These similarities include upregulation of the FOXA1 transcription factor and reduced expression of microRNAs-99a/100. We have previously identified direct regulation of FGFR3 by these two microRNAs and now search for further targets. Using a microarray meta-database we find potential FOXA1 regulation by microRNAs-99a/100. We confirm direct targeting of the FOXA1 3'UTR by microRNAs-99a/100 and also potential indirect regulation through microRNA-485-5p/SOX5/JUN-D/FOXL1 and microRNA-486/FOXO1a. In 292 benign and malignant urothelial samples, we find an inverse correlation between the expression of FOXA1 and microRNAs-99a/100 (r=-0.33 to -0.43, p<0.05). As for FGFR3 in UCC, tumors with high FOXA1 expression have lower rates of progression than those with low expression (Log rank p=0.009). Using global gene expression and CpG methylation profiling we find genotypic consequences of FOXA1 upregulation in UCC. Genetic changes are associated with regional hypomethylation, occur near FOXA1 binding sites, and mirror gene expression changes previously reported in FGFR3 mutant-UCC. These include gene silencing through aberrant hypermethylation (e.g. IGFBP3) and affect genes characterizing breast cancer sub-types (e.g. ERBB2). In conclusion, we have identified microRNAs-99a/100 mediate a direct relationship between FGFR3 and FOXA1 and potentially facilitate cross talk between these pathways in UCC.

  17. Error Analysis of non-TLD HDR Brachytherapy Dosimetric Techniques

    NASA Astrophysics Data System (ADS)

    Amoush, Ahmad

    The American Association of Physicists in Medicine Task Group Report43 (AAPM-TG43) and its updated version TG-43U1 rely on the LiF TLD detector to determine the experimental absolute dose rate for brachytherapy. The recommended uncertainty estimates associated with TLD experimental dosimetry include 5% for statistical errors (Type A) and 7% for systematic errors (Type B). TG-43U1 protocol does not include recommendation for other experimental dosimetric techniques to calculate the absolute dose for brachytherapy. This research used two independent experimental methods and Monte Carlo simulations to investigate and analyze uncertainties and errors associated with absolute dosimetry of HDR brachytherapy for a Tandem applicator. An A16 MicroChamber* and one dose MOSFET detectors† were selected to meet the TG-43U1 recommendations for experimental dosimetry. Statistical and systematic uncertainty analyses associated with each experimental technique were analyzed quantitatively using MCNPX 2.6‡ to evaluate source positional error, Tandem positional error, the source spectrum, phantom size effect, reproducibility, temperature and pressure effects, volume averaging, stem and wall effects, and Tandem effect. Absolute dose calculations for clinical use are based on Treatment Planning System (TPS) with no corrections for the above uncertainties. Absolute dose and uncertainties along the transverse plane were predicted for the A16 microchamber. The generated overall uncertainties are 22%, 17%, 15%, 15%, 16%, 17%, and 19% at 1cm, 2cm, 3cm, 4cm, and 5cm, respectively. Predicting the dose beyond 5cm is complicated due to low signal-to-noise ratio, cable effect, and stem effect for the A16 microchamber. Since dose beyond 5cm adds no clinical information, it has been ignored in this study. The absolute dose was predicted for the MOSFET detector from 1cm to 7cm along the transverse plane. The generated overall uncertainties are 23%, 11%, 8%, 7%, 7%, 9%, and 8% at 1cm, 2cm, 3cm

  18. 100 Gbit Interconnects and Above: The Need for Speed

    DTIC Science & Technology

    2007-01-01

    100Tb/s9 Board-board (~1m)2 $1/Gb 200Gb/ch3,6 $0.5/G/b 1Tb $0.1/G 5Tb Rack-rack (10-100m)1 $5/Gb $3/G 20Gb/ ch 100G...Critical need today $1/G 400G $0.25/G 1Tb/ ch 1. This market driven primarily by price 2. These markets are driven by needs/performance advantages...505) 272- 7845 Email: huffaker@chtm.unm.edu David Iams OIDA 1133 Connecticut Avenue, NW Suite 600 Washington, DC 20036-4329 Tel: (202) 785

  19. SRAG Measurements Performed During the Orion EFT-1 Mission

    NASA Technical Reports Server (NTRS)

    Gaza, Ramona

    2015-01-01

    The Exploration Flight Test 1 (EFT-1) was the first flight of the Orion Multi-Purpose Crew Vehicle (MPCV). The flight was launched on December 5, 2014, by a Delta IV Heavy rocket and lasted 4.5 hours. The EFT-1 trajectory involved one low altitude orbit and one high altitude orbit with an apogee of almost 6000 km. As a result of this particular flight profile, the Orion MPCV passed through intense regions of trapped protons and electron belts. In support of the radiation measurements aboard the EFT-1, the Space Radiation Analysis Group (SRAG) provided a Battery-operated Independent Radiation Detector (BIRD) based on Timepix radiation monitoring technology similar to that employed by the ISS Radiation Environmental Monitors (REM). In addition, SRAG provided a suite of optically and thermally stimulated luminescence detectors, with 2 Radiation Area Monitor (RAM) units collocated with the BIRD instrument for comparison purposes, and 6 RAM units distributed at different shielding configurations within the Orion MPCV. A summary of the EFT-1 Radiation Area Monitors (RAM) mission dose results obtained from measurements performed in the Space Radiation Dosimetry Laboratory at the NASA Johnson Space Center will be presented. Each RAM included LiF:Mg,Ti (TLD-100), (6)LiF:Mg,Ti (TLD-600), (7)LiF:Mg,Ti (TLD-700), Al2O3:C (Luxel trademark), and CaF2:Tm (TLD-300). The RAM mission dose values will be compared with the BIRD instrument total mission dose. In addition, a similar comparison will be shown for the ISS environment by comparing the ISS RAM data with data from the six Timepix-based REM units deployed on ISS as part of the NASA REM Technology Demonstration.

  20. The influence of neutron contamination on dosimetry in external photon beam radiotherapy.

    PubMed

    Horst, Felix; Czarnecki, Damian; Zink, Klemens

    2015-11-01

    Photon fields with energies above ∼7 MeV are contaminated by neutrons due to photonuclear reactions. Their influence on dosimetry-although considered to be very low-is widely unexplored. In this work, Monte Carlo based investigations into this issue performed with fluka and egsnrc are presented. A typical Linac head in 18 MV-X mode was modeled equivalently within both codes. egsnrc was used for the photon and fluka for the neutron production and transport simulation. Water depth dose profiles and the response of different detectors (Farmer chamber, TLD-100, TLD-600H, and TLD-700H chip) in five representative depths were simulated and the neutrons' impact (neutron absorbed dose relative to photon absorbed dose) was calculated. To take account of the neutrons' influence, a theoretically required correction factor was defined and calculated for five representative water depths. The neutrons' impact on the absorbed dose to water was found to be below 0.1% for all depths and their impact on the response of the Farmer chamber and the TLD-700H chip was found to be even less. For the TLD-100 and the TLD-600H chip it was found to be up to 0.3% and 0.7%, respectively. The theoretical correction factors to be applied to absorbed dose to water values measured with these four detectors in a depth different from the reference/calibration depth were calculated and found to be below 0.05% for the Farmer chamber and the TLD-700H chip, but up to 0.15% and 0.35% for the TLD-100 and TLD-600H chips, respectively. In thermoluminescence dosimetry the neutrons' influence (and therefore the additional inaccuracy in measurement) was found to be higher for TLD materials whose 6Li fraction is high, such as TLD-100 and TLD-600H, resulting from the thermal neutron capture reaction on 6Li. The impact of photoneutrons on the absorbed dose to water and on the response of a typical ionization chamber as well as three different types of TLD chips was quantified and was as expected found to be very

  1. Preliminary characterisation of new glass reference materials (GSA-1G, GSC-1G, GSD-1G and GSE-1G) by laser ablation-inductively coupled plasma-mass spectrometry using 193 nm, 213 nm and 266 nm wavelengths

    USGS Publications Warehouse

    Guillong, M.; Hametner, K.; Reusser, E.; Wilson, S.A.; Gunther, D.

    2005-01-01

    New glass reference materials GSA-1G, GSC-1G, GSD-1G and GSE-1G have been characterised using a prototype solid state laser ablation system capable of producing wavelengths of 193 nm, 213 nm and 266 nm. This system allowed comparison of the effects of different laser wavelengths under nearly identical ablation and ICP operating conditions. The wavelengths 213 nm and 266 nm were also used at higher energy densities to evaluate the influence of energy density on quantitative analysis. In addition, the glass reference materials were analysed using commercially available 266 nm Nd:YAG and 193 nm ArF excimer lasers. Laser ablation analysis was carried out using both single spot and scanning mode ablation. Using laser ablation ICP-MS, concentrations of fifty-eight elements were determined with external calibration to the NIST SRM 610 glass reference material. Instead of applying the more common internal standardisation procedure, the total concentration of all element oxide concentrations was normalised to 100%. Major element concentrations were compared with those determined by electron microprobe. In addition to NIST SRM 610 for external calibration, USGS BCR-2G was used as a more closely matrix-matched reference material in order to compare the effect of matrix-matched and non matrix-matched calibration on quantitative analysis. The results show that the various laser wavelengths and energy densities applied produced similar results, with the exception of scanning mode ablation at 266 nm without matrix-matched calibration where deviations up to 60% from the average were found. However, results acquired using a scanning mode with a matrix-matched calibration agreed with results obtained by spot analysis. The increased abundance of large particles produced when using a scanning ablation mode with NIST SRM 610, is responsible for elemental fractionation effects caused by incomplete vaporisation of large particles in the ICP.

  2. Liposomal gD Ectodomain (gD1-306) Vaccine Protects Against HSV2 Genital or Rectal Infection of Female and Male Mice

    PubMed Central

    Olson, K.; Macias, P.; Hutton, S.; Ernst, W. A.; Fujii, G.; Adler-Moore, J. P.

    2009-01-01

    Herpes simplex virus type 2 (HSV2) is the most common causative agent of genital herpes, with infection rates as high as 1 in 6 adults. The present studies were done to evaluate the efficacy of a liposomal HSV2 gD1-306 vaccine (L-gD1-306-HD) in an acute murine HSV2 infection model of intravaginal (female) or intrarectal (male or female) challenge. Two doses of L-gD1-306-HD containing 60μg gD1-306-HD and 15μg monophosphoryl lipid A (MPL) per dose provided protection against HSV2 intravaginal challenge (86-100% survival, P≤0.0003 vs control liposomes; P=0.06 vs L-gD1-306-HD without MPL). Both male and female mice (BALB/c and C57BL/6) immunized with L-gD1-306-HD/MPL were significantly protected against HSV2 intrarectal challenge, with higher survival rates compared to controls (71-100%, P≤0.007). L-gD1-306-HD/MPL also provided increased survival when compared to a liposomal peptide vaccine, L-gD264-285-HD/MPL (male BALB/c, P≤0.001; female BALB/c and male C57BL/6, P=0.06). Mice given L-gD1-306-HD/MPL also had minimal disease signs, reduced viral burden in their spinal cords and elevated neutralizing antibody titers in the females. The vaccine also stimulated gD1-306-HD specific splenocytes of both male and female mice with significantly elevated levels of IFN-γ compared to IL-4 (P≤0.01) indicating that there was an enhanced Th1 response. These results provide the first evidence that the L-gD1-306–HD vaccine can protect both male and female mice against intrarectal HSV2 challenge. PMID:19835825

  3. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for 125I and 103Pd brachytherapy sources relative to 60Co.

    PubMed

    Reed, J L; Rasmussen, B E; Davis, S D; Micka, J A; Culberson, W S; DeWerd, L A

    2014-12-01

    To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for (125)I and (103)Pd brachytherapy sources relative to (60)Co. LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a (60)Co teletherapy source. The brachytherapy sources measured were the Best 2301 (125)I seed, the OncoSeed 6711 (125)I seed, and the Best 2335 (103)Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the (60)Co irradiations. Monte Carlo (MC) simulations were used to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the (60)Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for (125)I and (103)Pd relative to (60)Co. The relative TLD intrinsic energy dependences (relative to (60)Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%-15% for (125)I and (103)Pd sources relative to (60)Co. TLD measurements of absolute dose around (125)I and (103)Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy.

  4. Fuel Preheat Effects on Soot-Field Structure in Laminar Gas Jet Diffusion Flames Burning in 0-g and 1-g

    NASA Technical Reports Server (NTRS)

    Konsur, Bogdan; Megaridis, Constantine M.; Griffin, Devon W.

    1999-01-01

    An experimental investigation conducted at the 2.2-s drop tower of the NASA Lewis Research Center is presented to quantify the influence of moderate fuel preheat on soot-field structure within 0-g laminar gas jet diffusion flames. Parallel work in 1-g is also presented to delineate the effect of elevated fuel temperatures on soot-field structure in buoyant flames. The experimental methodology implements jet diffusion flames of nitrogen-diluted acetylene fuel burning in quiescent air at atmospheric pressure. Fuel preheat of approximately 100 K in the 0-g laminar jet diffusion flames is found to reduce soot loadings in the annular region, but causes an increase in soot volume fractions at the centerline. In addition, fuel preheat reduces the radial extent of the soot field in 0-g. In 1-g, the same fuel preheat levels have a more moderated influence on soot loadings in the annular region, but are also seen to enhance soot concentrations near the axis low in the flame. The increased soot loadings near the flame centerline, as caused by fuel preheat, are consistent with the hypothesis that preheat levels of approximately 100 K enhance fuel pyrolysis rates. The results show that the growth stage of particles transported along the soot annulus is shortened both in 1-g and 0-g when elevated fuel temperatures are used.

  5. The Plasminogen Activator Inhibitor 1 4G/5G Polymorphism and the Risk of Alzheimer's Disease.

    PubMed

    Fekih-Mrissa, Najiba; Mansour, Malek; Sayeh, Aicha; Bedoui, Ines; Mrad, Meriem; Riahi, Anis; Mrissa, Ridha; Nsiri, Brahim

    2017-09-01

    The aim of this study was to determine whether plasminogen activator inhibitor 1 (PAI-1) is associated with the risk of Alzheimer's disease (AD) in Tunisian patients. We analyzed the genotype and allele frequency distribution of the PAI-1 polymorphism in 60 Tunisian patients with AD and 120 healthy controls. The results show a significantly increased risk of AD in carriers of the 4G/4G and 4G/5G genotypes versus the wild-type 5G/5G genotype (4G/4G: 28.33% in patients vs 10.0% in controls; P < 10 -3 ; OR = 8.78; 4G/5G: 55.0% in patients vs 38.33% in controls; OR = 4.45; P < 10 -3 ). The 4G allele was also more frequently found in patients compared with controls; P < 10 -3 ; OR = 3.07. For all participants and by gender, homozygotic carriers (4G/4G) were at an increased risk of AD over heterozygotes and women were at an increased risk over their male genotype counterparts. The odds ratio for AD among 4G/4G carriers for any group was approximately twice that of heterozygotes in the same group. Women homozygotes ranked highest for AD risk (OR = 20.8) and, in fact, women heterozygotes (OR = 9.03) ranked higher for risk than male homozygotes (OR = 6.12). These preliminary exploratory results should be confirmed in a larger study.

  6. Liposomal gD ectodomain (gD1-306) vaccine protects against HSV2 genital or rectal infection of female and male mice.

    PubMed

    Olson, K; Macias, P; Hutton, S; Ernst, W A; Fujii, G; Adler-Moore, J P

    2009-12-11

    Herpes simplex virus type 2 (HSV2) is the most common causative agent of genital herpes, with infection rates as high as 1 in 6 adults. The present studies were done to evaluate the efficacy of a liposomal HSV2 gD(1-306) vaccine (L-gD(1-306)-HD) in an acute murine HSV2 infection model of intravaginal (female) or intrarectal (male or female) challenge. Two doses of L-gD(1-306)-HD containing 60 microg gD(1-306)-HD and 15 microg monophosphoryl lipid A (MPL) per dose provided protection against HSV2 intravaginal challenge (86-100% survival, P< or =0.0003 vs. control liposomes; P=0.06 vs. L-gD(1-306)-HD without MPL). Both male and female mice (BALB/c and C57BL/6) immunized with L-gD(1-306)-HD/MPL were significantly protected against HSV2 intrarectal challenge, with higher survival rates compared to controls (71-100%, P< or =0.007). L-gD(1-306)-HD/MPL also provided increased survival when compared to a liposomal peptide vaccine, L-gD(264-285)-HD/MPL (male BALB/c, PgD(1-306)-HD/MPL also had minimal disease signs, reduced viral burden in their spinal cords and elevated neutralizing antibody titers in the females. The vaccine also stimulated gD(1-306)-HD specific splenocytes of both male and female mice with significantly elevated levels of IFN-gamma compared to IL-4 (P< or =0.01) indicating that there was an enhanced Th1 response. These results provide the first evidence that the L-gD(1-306)-HD vaccine can protect both male and female mice against intrarectal HSV2 challenge.

  7. Prognostic value of the PAI-1 4G/5G polymorphism in invasive ductal carcinoma of the breast.

    PubMed

    Yagmurdur, M C; Atac, F B; Tutar, N U; Verdi, H; Isiklar, I; Ozdemir, B H; Ozbek, N; Karakayali, H; Haberal, M

    2008-01-01

    The study group was derived from the archive materials of 55 invasive ductal breast cancer (IDC) patients who had undergone breast-preserving surgery (partial mastectomy/ axillary dissection). All patients included in the study had clinically T(1)-2, N0-M0 invasive ductal carcinoma. Genomic DNA species were extracted from paraffin-embedded blocks, and plasminogen activator inhibitor type-1 (PAI-1) gene 4G/5G genotyping was done by polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP). Patient demographics, axillary metastasis status, metastatic lymph nodi/total dissected lymph nodes from axilla, histopathologic characteristics of tumors, local recurrences, and survival ratio were assessed. PAI-1 4G/5G genotype frequencies were 4G/4G (64%), 4G/5G (31%), and 5G/5G (5%) in the patient group. According to the results based on frequencies, the demographics were not different. Five-year local recurrence rate of 4G/5G patients was the lowest (2/17, 12%) (P = 0.02). Also five-year distant metastases ratio of 4G/5G patients was the highest (18%) (P = 0.01). Five- and 10-year disease-free survival rates for the 4G/4G, 4G/5G, and 5G/5G groups were 97% and 94%, 82% and 77%, and 100% and 94%, respectively (P = 0.004). The results of this study indicate that the 4G allele in the PAI 1 gene had a negative impact on local recurrence and disease-free survival of patients with clinical T(1)-2N0M0 IDC.

  8. Design and feasibility of a multi-detector neutron spectrometer for radiation protection applications based on thermoluminescent 6LiF:Ti,Mg (TLD-600) detectors

    NASA Astrophysics Data System (ADS)

    Lis, M.; Gómez-Ros, J. M.; Bedogni, R.; Delgado, A.

    2008-01-01

    The design of a neutron detector with spectrometric capability based on thermoluminescent (TL) 6LiF:Ti,Mg (TLD-600) dosimeters located along three perpendicular axis within a single polyethylene (PE) sphere has been analyzed. The neutron response functions have been calculated in the energy range from 10 -8 to 100 MeV with the Monte Carlo (MC) code MCNPX 2.5 and their shape and behaviour have been used to discuss a suitable configuration for an actual instrument. The feasibility of such a device has been preliminary evaluated by the simulation of exposure to 241Am-Be, bare 252Cf and Fe-PE moderated 252Cf sources. The expected accuracy in the evaluation of energy quantities has been evaluated using the unfolding code FRUIT. The obtained results together with additional calculations performed using MAXED and GRAVEL codes show the spectrometric capability of the proposed design for radiation protection applications, especially in the range 1 keV-20 MeV.

  9. Water dissociation on Mn(1×1)/Ag(100)

    DOE PAGES

    Arble, Chris; Tong, Xiao; Giordano, Livia; ...

    2016-08-19

    In this work we utilize experimental and simulation techniques to examine the molecular level interaction of water with a MnO(1×1) thin film deposited onto Ag(100). The formation of MnO(1×1)/Ag(100) was characterized by low energy electron diffraction and scanning tunneling microscopy. Density functional theory (DFT) shows MnO(1×1) is thermodynamically more stable than MnO(2×1) by –0.4 eV per MnO. Upon exposure to 2.5 Torr water vapor at room temperature, X-ray photoemission spectroscopy results show extensive surface hydroxylation attributed to reactivity at MnO(1×1) terrace sites. DFT calculations of a water monomer on MnO(1×1)/Ag(100) show the dissociated form is energetically more favorable than molecularmore » adsorption, with a hydroxylation activation barrier 0.4 eV per H 2O. Lastly, these results are discussed and contrasted with previous studies of MgO/Ag(100) which show a stark difference in behavior for water dissociation.« less

  10. The influence of neutron contamination on dosimetry in external photon beam radiotherapy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Horst, Felix, E-mail: felix.ernst.horst@kmub.thm.de; Czarnecki, Damian; Zink, Klemens

    Purpose: Photon fields with energies above ∼7 MeV are contaminated by neutrons due to photonuclear reactions. Their influence on dosimetry—although considered to be very low—is widely unexplored. Methods: In this work, Monte Carlo based investigations into this issue performed with FLUKA and EGSNRC are presented. A typical Linac head in 18 MV-X mode was modeled equivalently within both codes. EGSNRC was used for the photon and FLUKA for the neutron production and transport simulation. Water depth dose profiles and the response of different detectors (Farmer chamber, TLD-100, TLD-600H, and TLD-700H chip) in five representative depths were simulated and the neutrons’more » impact (neutron absorbed dose relative to photon absorbed dose) was calculated. To take account of the neutrons’ influence, a theoretically required correction factor was defined and calculated for five representative water depths. Results: The neutrons’ impact on the absorbed dose to water was found to be below 0.1% for all depths and their impact on the response of the Farmer chamber and the TLD-700H chip was found to be even less. For the TLD-100 and the TLD-600H chip it was found to be up to 0.3% and 0.7%, respectively. The theoretical correction factors to be applied to absorbed dose to water values measured with these four detectors in a depth different from the reference/calibration depth were calculated and found to be below 0.05% for the Farmer chamber and the TLD-700H chip, but up to 0.15% and 0.35% for the TLD-100 and TLD-600H chips, respectively. In thermoluminescence dosimetry the neutrons’ influence (and therefore the additional inaccuracy in measurement) was found to be higher for TLD materials whose {sup 6}Li fraction is high, such as TLD-100 and TLD-600H, resulting from the thermal neutron capture reaction on {sup 6}Li. Conclusions: The impact of photoneutrons on the absorbed dose to water and on the response of a typical ionization chamber as well as three

  11. Determination of the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters for {sup 125}I and {sup 103}Pd brachytherapy sources relative to {sup 60}Co

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reed, J. L., E-mail: jlreed2@wisc.edu; Micka, J. A.; Culberson, W. S.

    Purpose: To determine the intrinsic energy dependence of LiF:Mg,Ti thermoluminescent dosimeters (TLD-100) for {sup 125}I and {sup 103}Pd brachytherapy sources relative to {sup 60}Co. Methods: LiF:Mg,Ti TLDs were irradiated with low-energy brachytherapy sources and with a {sup 60}Co teletherapy source. The brachytherapy sources measured were the Best 2301 {sup 125}I seed, the OncoSeed 6711 {sup 125}I seed, and the Best 2335 {sup 103}Pd seed. The TLD light output per measured air-kerma strength was determined for the brachytherapy source irradiations, and the TLD light output per air kerma was determined for the {sup 60}Co irradiations. Monte Carlo (MC) simulations were usedmore » to calculate the dose-to-TLD rate per air-kerma strength for the brachytherapy source irradiations and the dose to TLD per air kerma for the {sup 60}Co irradiations. The measured and MC-calculated results for all irradiations were used to determine the TLD intrinsic energy dependence for {sup 125}I and {sup 103}Pd relative to {sup 60}Co. Results: The relative TLD intrinsic energy dependences (relative to {sup 60}Co) and associated uncertainties (k = 1) were determined to be 0.883 ± 1.3%, 0.870 ± 1.4%, and 0.871 ± 1.5% for the Best 2301 seed, OncoSeed 6711 seed, and Best 2335 seed, respectively. Conclusions: The intrinsic energy dependence of TLD-100 is dependent on photon energy, exhibiting changes of 13%–15% for {sup 125}I and {sup 103}Pd sources relative to {sup 60}Co. TLD measurements of absolute dose around {sup 125}I and {sup 103}Pd brachytherapy sources should explicitly account for the relative TLD intrinsic energy dependence in order to improve dosimetric accuracy.« less

  12. 7 CFR 762.1-762.100 - [Reserved

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 7 2012-01-01 2012-01-01 false [Reserved] 762.1-762.100 Section 762.1-762.100 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS GUARANTEED FARM LOANS §§ 762.1-762.100 [Reserved] ...

  13. 7 CFR 762.1-762.100 - [Reserved

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 7 2014-01-01 2014-01-01 false [Reserved] 762.1-762.100 Section 762.1-762.100 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS GUARANTEED FARM LOANS §§ 762.1-762.100 [Reserved] ...

  14. 7 CFR 762.1-762.100 - [Reserved

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 7 2011-01-01 2011-01-01 false [Reserved] 762.1-762.100 Section 762.1-762.100 Agriculture Regulations of the Department of Agriculture (Continued) FARM SERVICE AGENCY, DEPARTMENT OF AGRICULTURE SPECIAL PROGRAMS GUARANTEED FARM LOANS §§ 762.1-762.100 [Reserved] ...

  15. Tubeimoside-1 induces oxidative stress-mediated apoptosis and G0/G1 phase arrest in human prostate carcinoma cells in vitro

    PubMed Central

    Yang, Jing-bo; Khan, Muhammad; He, Yang-yang; Yao, Min; Li, Yong-ming; Gao, Hong-wen; Ma, Tong-hui

    2016-01-01

    Aim: Tubeimoside-1 (TBMS1), a triterpenoid saponin extracted from the Chinese herbal medicine Bolbostemma paniculatum (Maxim) Franquet (Cucurbitaceae), has shown anticancer activities in various cancer cell lines. The aim of this study was to investigate the anticancer activity and molecular targets of TBMS1 in human prostate cancer cells in vitro. Methods: DU145 and P3 human prostate cancer cells were treated with TBMS1. Cell viability and apoptosis were detected. ROS generation, mitochondrial membrane potential and cell cycle profile were examined. Western blotting was used to measure the expression of relevant proteins in the cells. Results: TBMS1 (5–100 μmol/L) significantly suppressed the viability of DU145 and P3 cells with IC50 values of approximately 10 and 20 μmol/L, respectively. Furthermore, TBMS1 dose-dependently induced apoptosis and cell cycle arrest at G0/G1 phase in DU145 and P3 cells. In DU145 cells, TBMS1 induced mitochondrial apoptosis, evidenced by ROS generation, mitochondrial dysfunction, endoplasmic reticulum stress, modulated Bcl-2 family protein and cleaved caspase-3, and activated ASK-1 and its downstream targets p38 and JNK. The G0/G1 phase arrest was linked to increased expression of p53 and p21 and decreased expression of cyclin E and cdk2. Co-treatment with Z-VAD-FMK (pan-caspase inhibitor) could attenuate TBMS1-induced apoptosis but did not prevent G0/G1 arrest. Moreover, co-treatment with NAC (ROS scavenger), SB203580 (p38 inhibitor), SP600125 (JNK inhibitor) or salubrinal (ER stress inhibitor) significantly attenuated TBMS1-induced apoptosis. Conclusion: TBMS1 induces oxidative stress-mediated apoptosis in DU145 human prostate cancer cells in vitro via the mitochondrial pathway. PMID:27292614

  16. Geological studies of the COST nos. G-1 and G-2 wells, United States North Atlantic outer continental shelf

    USGS Publications Warehouse

    Scholle, Peter A.; Wenkam, Chiye R.

    1982-01-01

    The COST Nos. G-1 and G-2 wells (fig. 1) are the second and third deep stratigraphic test wells drilled in the North Atlantic Outer Continental Shelf of the United States. COST No. G-1 was drilled in the Georges Bank basin to a total depth of 16,071 ft (4,898 m). G-1 bottomed in phyllite, slate, and metaquartzite overlain by weakly metamorphosed dolomite, all of Cambrian age. From approximately 15,600 to 12,400 ft (4,755 to 3,780 m) the strata are Upper Triassic(?), Lower Jurassic(?), and Middle Jurassic, predominantly red shales, sandstones, and conglomerates. Thin, gray Middle Jurassic beds of shale, sandstone, limestone, and dolomite occur from 12,400 to 9,900 ft (3,780 to 3,018 m). From 9,900 to 1,030 ft (3,018 to 314 m) are coarse-grained unconsolidated sands and loosely cemented sandstones, with beds of gray shale, lignite, and coal. The microfossils indicate the rocks are Upper Jurassic from 10,100 ft (3,078 m) up to 5,400 ft (1,646 m) and Cretaceous from that depth to 1,030 ft (314 m). No younger or shallower rocks were recovered in the drilling at the COST No. G-1 site, but an Eocene limestone is inferred to be disconformable over Santonian strata. The Jurassic strata of the COST No. G-1 well were deposited in shallow marine, marginal marine, and nonmarine environments, which changed to a dominantly shallow marine but still nearshore environment in the Cretaceous. The COST No. G-2 well was drilled 42 statute miles {68 km) east of the G-1 site, still within the Georges Bank basin, to a depth of 21,874 ft (6,667 m). The bottom 40 ft (12 m) of salt and anhydrite is overlain by approximately 7,000 ft {2,134 m) of Upper Triassic{?), Lower Jurassic{?) and Middle Jurassic dolomite, limestone, and interbedded anhydrite from 21,830 to 13,615 ft (6,654 to 4,153 m). From 13,500 to 9,700 ft (4,115 to 2,957 m) are Middle Jurassic limestones with interbedded sandstone. From 9,700 to 4,000 ft (2,957 to 1,219 m) are Upper Jurassic and Cretaceous interbedded sandstones and

  17. Total and free cortisol levels during 1 μg, 25 μg, and 250 μg cosyntropin stimulation tests compared to insulin tolerance test: results of a randomized, prospective, pilot study.

    PubMed

    Peechakara, Seenia; Bena, James; Clarke, Nigel J; McPhaul, Michael J; Reitz, Richard E; Weil, Robert J; Recinos, Pablo; Kennedy, Laurence; Hamrahian, Amir H

    2017-09-01

    The appropriate cosyntropin dose during cosyntropin stimulation tests remains uncertain. We conducted a prospective, randomized pilot study to compare 1 μg IV low dose cosyntropin test, 25 μg IM medium dose cosyntropin test, and 250 μg IM standard dose cosyntropin test to evaluate secondary adrenal insufficiency. Insulin tolerance test was used as the gold standard. The study included patients with hypothalamic/pituitary disease (n  = 10) with at least one pituitary axis deficiency other than ACTH deficiency and controls (n  = 12). All tests were done in random order. Sensitivity and specificity were calculated for total cortisol and serum free cortisol cut-off levels during cosyntropin stimulation tests. The median (range) age and F/M sex ratios for patients and controls were 54 years (23-62), 2/8, and 33 years (21-51), 6/6, respectively. The best total cortisol cut-off during low dose cosyntropin test, medium dose cosyntropin test, 30 min and 60 min standard dose cosyntropin test were 14.6 μg/dL (100% sensitivity & specificity), 18.7 μg/dL (100% sensitivity, 88% specificity), 16.1 (100% sensitivity & specificity), and 19.5 μg/dL (100% sensitivity & specificity), respectively. There was no difference in the ROC curve for cortisol values between the cosyntropin stimulation tests (p  > 0.41). Using a cortisol cut-off of 18 μg/dL during cosyntropin stimulation tests, only cortisol level at 30 min during standard dose cosyntropin test provided discrimination similar to insulin tolerance test. The best peak free cortisol cut-off levels were 1 μg/dL for insulin tolerance test, 0.9 μg/dL for low dose cosyntropin test, 0.9 μg/dL for medium dose cosyntropin test, and 0.9 μg/dL and 1.3 μg/dL for 30 min and 60 min standard dose cosyntropin test, respectively. All cosyntropin stimulation tests had excellent correlations with insulin tolerance test, when appropriate cut-offs were used. This pilot study does not

  18. The -675 4G/5G polymorphism in the PAI-1 gene may not contribute to the risk of PCOS.

    PubMed

    Zhang, T-T; Yuan, L; Yang, Y-M; Ren, Y

    2014-08-01

    The association between the -675 4G/5G polymorphism in PAI-1 gene and PCOS has been studied with inconclusive results. We sought to investigate this inconsistency by performing a comprehensive meta-analysis on the polymorphism. Searches were performed in the PubMed, Embase, CNKI and Wanfang databases, covering all papers. Statistical analysis was performed using Revman5.2 and STATA11.0 software. A total of 11 case-control studies were extracted on the polymorphism involving 1861 PCOS cases and 1187 controls. The results showed that, no significant increased/decreased risk were found for the polymorphism for PCOS: OR = 1.03, 95% CI = 0.77-1.66, p = 0.52 for 4G4G + 4G5G vs. 5G5G; OR = 0.99, 95% CI = 0.66-1.49, p = 0.96 for 4G4G vs. 5G5G + 4G5G; OR = 1.08, 95% CI = 0.66-1.79, p = 0.76 for 4G4G vs. 5G5G; OR = 1.11, 95% CI = 0.78-1.58, p = 0.56 for 4G5G vs. 5G5G; OR = 1.00, 95% CI = 0.71-1.41, p = 0.99 for 4G vs. 5G. In the further subgroup analysis by ethnicity, we did not find a significant association between the polymorphism for PCOS risk in either Asians or Europeans. Our findings demonstrated that -675 4G/5G polymorphism in the PAI-1 gene might not be a risk factor for the development of PCOS.

  19. Azithromycin 1.5g Over 5 Days Compared to 1g Single Dose in Urethral Mycoplasma genitalium: Impact on Treatment Outcome and Resistance.

    PubMed

    Read, Tim R H; Fairley, Christopher K; Tabrizi, Sepehr N; Bissessor, Melanie; Vodstrcil, Lenka; Chow, Eric P F; Grant, Mieken; Danielewski, Jennifer; Garland, Suzanne M; Hocking, Jane S; Chen, Marcus Y; Bradshaw, Catriona S

    2017-02-01

    We evaluated the impact of extended azithromycin (1.5g over 5 days) on selection of macrolide resistance and microbiological cure in men with Mycoplasma genitalium urethritis during 2013-2015 and compared this to cases treated with azithromycin 1g in 2012-2013. Microbiological cure was determined for men with M. genitalium urethritis treated with azithromycin 1.5g using quantitative polymerase chain reaction specific for M. genitalium DNA on samples 14-100 days post-treatment. Pre- and post-treatment macrolide resistance mutations were detected by sequencing the 23 S gene. There was no difference in proportions with microbiological cure between azithromycin 1.5g and 1g: 62/106 (58%; 95% confidence interval [CI], 49%, 68%) and 56/107 (52%; 95%CI 42-62%), P = .34, respectively. Also, there was no difference in the proportion of wild-type 23 S rRNA (presumed macrolide sensitive) infections cured after 1.5g and azithromycin 1g: 28/34 (82%; 95%CI 65-92%) and 49/60 (82%; 95%CI 70-90%), P=1.0, respectively. There was no difference between 1.5g and 1g in the proportions of wild-type infections with post-treatment resistance mutations: 4/34 (12%; 95%CI 3-27%) and 11/60 (18%; 95%CI 10-30%), respectively, P = .40. Pre-treatment resistance was present in 51/98 (52%; 95%CI 42-62%) cases in 2013-2015 compared to 47/107 (44%; 95%CI 34-54%) in 2012-2013, P = .25. Extended azithromycin 1.5g was no more effective than a single 1g dose at achieving cure of M. genitalium urethritis and importantly did not reduce the selection of macrolide resistance. Nonmacrolide and new approaches for the treatment of M. genitalium urethritis are required. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  20. Verification of an on line in vivo semiconductor dosimetry system for TBI with two TLD procedures.

    PubMed

    Sánchez-Doblado, F; Terrón, J A; Sánchez-Nieto, B; Arráns, R; Errazquin, L; Biggs, D; Lee, C; Núñez, L; Delgado, A; Muñiz, J L

    1995-01-01

    This work presents the verification of an on line in vivo dosimetry system based on semiconductors. Software and hardware has been designed to convert the diode signal into absorbed dose. Final verification was made in the form of an intercomparison with two independent thermoluminiscent (TLD) dosimetry systems, under TBI conditions.

  1. Evaluation of effective dose for a patient under Ga-67 nuclear examination using TLD, water phantom and a simplified model

    PubMed Central

    Chu, Kuang Hua; Lin, Yu Ting; Hsu, Chia Chun; Chen, Chien Yi; Pan, Lung Kwang

    2012-01-01

    This study evaluated the effective dose of Ga-67 for a patient undergoing Ga-67 citrate nuclear examination by applying thermoluminescent dosimeter (TLD) technique and an indigenous water phantom. The Ga-67 radionuclide remaining in the body inevitably generated a measurable internal dose even though gamma camera scanning took only minutes to complete the clinical examination. For effective simulation of the cumulated effective dose for a patient undergoing examination, 150 TLDs were placed inside the water phantom for 6 days to monitor the gamma ray dose from the distributed Ga-67 citrate solution. The inserted TLDs represented internal organs, and the effective dose was calculated according to data in the ICRP-60 report. The water phantom was designed to model the body of a healthy human weighing 70 kg, and the water that was mixed with Ga-67 citrate solution was slowly replaced with fresh feed water to yield the required biological half life of the phantom. After continuously feeding in fresh water throughout the 6 days of TLD exposure, the TLDs were analyzed to determine the effective doses from the various biological half lives of the phantom. The derived effective dose of 185 MBq Ga-67 citrate solution for male/female (M/F) was 10.7/12.2, 10.7/12.0, 8.7/9.9 and 6.0/6.8 mSv, of biological half lives of 6.0, 4.5, 3.0 and 1.5 days, respectively. Although these experimental results correlated well with earlier empirical studies, they were lower than most calculated values. The cumulated uncertainty in the effective dose was 12.5–19.4%, which was acceptable in terms of both TLD counting statistic and reproducibility. PMID:22915780

  2. Big Data over a 100G network at Fermilab

    DOE PAGES

    Garzoglio, Gabriele; Mhashilkar, Parag; Kim, Hyunwoo; ...

    2014-06-11

    As the need for Big Data in science becomes ever more relevant, networks around the world are upgrading their infrastructure to support high-speed interconnections. To support its mission, the high-energy physics community as a pioneer in Big Data has always been relying on the Fermi National Accelerator Laboratory to be at the forefront of storage and data movement. This need was reiterated in recent years with the data-taking rate of the major LHC experiments reaching tens of petabytes per year. At Fermilab, this resulted regularly in peaks of data movement on the Wide area network (WAN) in and out ofmore » the laboratory of about 30 Gbit/s and on the Local are network (LAN) between storage and computational farms of 160 Gbit/s. To address these ever increasing needs, as of this year Fermilab is connected to the Energy Sciences Network (ESnet) through a 100 Gb/s link. To understand the optimal system-and application-level configuration to interface computational systems with the new highspeed interconnect, Fermilab has deployed a Network Research & Development facility connected to the ESnet 100G Testbed. For the past two years, the High Throughput Data Program (HTDP) has been using the Testbed to identify gaps in data movement middleware [5] when transferring data at these high-speeds. The program has published evaluations of technologies typically used in High Energy Physics, such as GridFTP [4], XrootD [9], and Squid [8]. Furthermore, this work presents the new R&D facility and the continuation of the evaluation program.« less

  3. Big Data over a 100G network at Fermilab

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Garzoglio, Gabriele; Mhashilkar, Parag; Kim, Hyunwoo

    As the need for Big Data in science becomes ever more relevant, networks around the world are upgrading their infrastructure to support high-speed interconnections. To support its mission, the high-energy physics community as a pioneer in Big Data has always been relying on the Fermi National Accelerator Laboratory to be at the forefront of storage and data movement. This need was reiterated in recent years with the data-taking rate of the major LHC experiments reaching tens of petabytes per year. At Fermilab, this resulted regularly in peaks of data movement on the Wide area network (WAN) in and out ofmore » the laboratory of about 30 Gbit/s and on the Local are network (LAN) between storage and computational farms of 160 Gbit/s. To address these ever increasing needs, as of this year Fermilab is connected to the Energy Sciences Network (ESnet) through a 100 Gb/s link. To understand the optimal system-and application-level configuration to interface computational systems with the new highspeed interconnect, Fermilab has deployed a Network Research & Development facility connected to the ESnet 100G Testbed. For the past two years, the High Throughput Data Program (HTDP) has been using the Testbed to identify gaps in data movement middleware [5] when transferring data at these high-speeds. The program has published evaluations of technologies typically used in High Energy Physics, such as GridFTP [4], XrootD [9], and Squid [8]. Furthermore, this work presents the new R&D facility and the continuation of the evaluation program.« less

  4. Plasminogen activator inhibitor-1 4G/5G polymorphism and retinopathy risk in type 2 diabetes: a meta-analysis.

    PubMed

    Zhang, Tengyue; Pang, Chong; Li, Ningdong; Zhou, Elaine; Zhao, Kanxing

    2013-01-02

    Mounting evidence has suggested that plasminogen activator inhibitor-1 (PAI-1) is a candidate for increased risk of diabetic retinopathy. Studies have reported that insertion/deletion polymorphism in the PAI-1 gene may influence the risk of this disease. To comprehensively address this issue, we performed a meta-analysis to evaluate the association of PAI-1 4G/5G polymorphism with diabetic retinopathy in type 2 diabetes. Data were retrieved in a systematic manner and analyzed using Review Manager and STATA Statistical Software. Crude odds ratios (ORs) with 95% confidence intervals (CIs) were used to assess the strength of associations. Nine studies with 1, 217 cases and 1, 459 controls were included. Allelic and genotypic comparisons between cases and controls were evaluated. Overall analysis suggests a marginal association of the 4G/5G polymorphism with diabetic retinopathy (for 4G versus 5G: OR 1.13, 95%CI 1.01 to 1.26; for 4G/4G versus 5G/5G: OR 1.30, 95%CI 1.04 to 1.64; for 4G/4G versus 5G/5G + 4G/5G: OR 1.26, 95%CI 1.05 to 1.52). In subgroup analysis by ethnicity, we found an association among the Caucasian population (for 4G versus 5G: OR 1.14, 95% CI 1.00 to 1.30; for 4G/4G versus 5G/5G: OR 1.33, 95%CI 1.02 to 1.74; for 4G/4G versus 5G/5G + 4G/5G: OR 1.41, 95%CI 1.13 to 1.77). When stratified by the average duration of diabetes, patients with diabetes histories longer than 10 years have an elevated susceptibility to diabetic retinopathy than those with shorter histories (for 4G/4G versus 5G/5G: OR 1.47, 95%CI 1.08 to 2.00). We also detected a higher risk in hospital-based studies (for 4G/4G versus 5G/5G+4G/5G: OR 1.27, 95%CI 1.02 to 1.57). The present meta-analysis suggested that 4G/5G polymorphism in the PAI-1 gene potentially increased the risk of diabetic retinopathy in type 2 diabetes and showed a discrepancy in different ethnicities. A higher susceptibility in patients with longer duration of diabetes (more than 10 years) indicated a gene

  5. Plasminogen activator inhibitor-1 4G/5G polymorphism and retinopathy risk in type 2 diabetes: a meta-analysis

    PubMed Central

    2013-01-01

    Background Mounting evidence has suggested that plasminogen activator inhibitor-1 (PAI-1) is a candidate for increased risk of diabetic retinopathy. Studies have reported that insertion/deletion polymorphism in the PAI-1 gene may influence the risk of this disease. To comprehensively address this issue, we performed a meta-analysis to evaluate the association of PAI-1 4G/5G polymorphism with diabetic retinopathy in type 2 diabetes. Methods Data were retrieved in a systematic manner and analyzed using Review Manager and STATA Statistical Software. Crude odds ratios (ORs) with 95% confidence intervals (CIs) were used to assess the strength of associations. Results Nine studies with 1, 217 cases and 1, 459 controls were included. Allelic and genotypic comparisons between cases and controls were evaluated. Overall analysis suggests a marginal association of the 4G/5G polymorphism with diabetic retinopathy (for 4G versus 5G: OR 1.13, 95%CI 1.01 to 1.26; for 4G/4G versus 5G/5G: OR 1.30, 95%CI 1.04 to 1.64; for 4G/4G versus 5G/5G + 4G/5G: OR 1.26, 95%CI 1.05 to 1.52). In subgroup analysis by ethnicity, we found an association among the Caucasian population (for 4G versus 5G: OR 1.14, 95% CI 1.00 to 1.30; for 4G/4G versus 5G/5G: OR 1.33, 95%CI 1.02 to 1.74; for 4G/4G versus 5G/5G + 4G/5G: OR 1.41, 95%CI 1.13 to 1.77). When stratified by the average duration of diabetes, patients with diabetes histories longer than 10 years have an elevated susceptibility to diabetic retinopathy than those with shorter histories (for 4G/4G versus 5G/5G: OR 1.47, 95%CI 1.08 to 2.00). We also detected a higher risk in hospital-based studies (for 4G/4G versus 5G/5G+4G/5G: OR 1.27, 95%CI 1.02 to 1.57). Conclusions The present meta-analysis suggested that 4G/5G polymorphism in the PAI-1 gene potentially increased the risk of diabetic retinopathy in type 2 diabetes and showed a discrepancy in different ethnicities. A higher susceptibility in patients with longer duration of diabetes (more than 10

  6. TU-F-BRE-07: In Vivo Neutron Detection in Patients Undergoing Stereotactic Ablative Radiotherapy (SABR) for Primary Kidney Cancer Using 6Li and 7Li Enriched TLD Pairs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lonski, P; Kron, T; RMIT University, Melbourne, Victoria

    Purpose: Stereotactic ablative radiotherapy (SABR) for primary kidney cancer often involves the use of high-energy photons combined with a large number of monitor units. While important for risk assessment, the additional neutron dose to untargeted healthy tissue is not accounted for in treatment planning. This work aims to detect out-of-field neutrons in vivo for patients undergoing SABR with high-energy (>10 MV) photons and provides preliminary estimates of neutron effective dose. Methods: 3 variations of high-sensitivity LiF:Mg,Cu,P thermoluminescent dosimeter (TLD) material, each with varying {sup 6}Li / {sup 7}Li concentrations, were used in custom-made Perspex holders for in vivo measurements. Themore » variation in cross section for thermal neutrons between Li isotopes was exploited to distinguish neutron from photon signal. Measurements were made out-of-field for 7 patients, each undergoing 3D-conformal SABR treatment for primary kidney cancer on a Varian 21iX linear accelerator. Results: In vivo measurements show increased signal for the {sup 6}Li enriched material for patients treated with 18 MV photons. Measurements on one SABR patient treated using only 6 MV showed no difference between the 3 TLD materials. The out-of-field photon signal decreased exponentially with distance from the treatment field. The neutron signal, taken as the difference between {sup 6}Li enriched and {sup 7}Li enriched TLD response, remains almost constant up to 50 cm from the beam central axis. Estimates of neutron effective dose from preliminary TLD calibration suggest between 10 and 30 mSv per 1000 MU delivered at 18 MV for the 7 patients. Conclusion: TLD was proven to be a useful tool for the purpose of in vivo neutron detection at out-of-field locations. Further work is required to understand the relationship between TL signal and neutron dose. Dose estimates based on preliminary TLD calibration in a neutron beam suggest the additional neutron dose was <30 mSv per 1000 MU

  7. FADING EFFECT OF LiF:Mg,Ti AND LiF:Mg,Cu,P Ext-Rad AND WHOLE-BODY DETECTORS.

    PubMed

    Pereira, J; Pereira, M F; Rangel, S; Saraiva, M; Santos, L M; Cardoso, J V; Alves, J G

    2016-09-01

    Thermoluminescence dosemeters are widely used in individual and environmental monitoring. The aim of this work was to compare the thermal stability of dosemeters of the Ext-Rad and whole-body card types with LiF:Mg,Ti and LiF:Mg,Cu,P detectors stored at different temperatures and periods. The dosemeters were stored at 0°C, room temperature and 40°C for periods that lasted 8, 30, 45, 90 and 120 d. In general, TLD-100H detectors present higher TL signal stability than TLD-100 detectors. The intensity of the signal remained constant for both materials for storage periods at 0°C. At RT the same results was observed for TLD-100H. For TLD-100 detectors, a maximum variation of 22 % was registered for the longest period. At 40°C the TL signal decreased with storage time for both detectors. The TL signal of TLD-100H detectors presented maximum variations of 12 % whereas for TLD-100 detectors, larger variations of 25 % were observed. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  8. Sensitivity and specificity of modified 100-g oral glucose tolerance tests for diagnosis of gestational diabetes mellitus.

    PubMed

    Hansarikit, Jarunee; Manotaya, Saknan

    2011-05-01

    To study the sensitivity and specificity of the modified 100-g oral glucose tolerance test for diagnosis of gestational diabetes mellitus (GDM). Medical records of pregnant women attending the antenatal clinic of King Chulalongkorn Memorial Hospital, Thailand, who underwent a 100-g oral glucose tolerance test (OGTT) during March 2004 to September 2009, were retrospectively reviewed. Three modified criteria were proposed for diagnosis of GDM. The screening efficacy of the modified criteria were assessed, using the National Diabetes Data Group (NDDG) criterion as gold standard. A total of 729 records were reviewed, 511 were included for analysis. Using the NDDG criterion as the gold standard, the modified II criterion has the highest sensitivity of 96.8%, and the highest accuracy of 90.8%. The modified II criterion can detect the same proportion of maternal and neonatal complications, compared to the NDDG criterion. The modified II criterion, using the fasting plasma glucose and 2-hour plasma glucose measurements, showed high sensitivity and accuracy, with moderate specificity for diagnosis of GDM. Its potential use as an alternative to standard 100-g OGTT should be evaluated in the prospective study.

  9. Relationship of metabolic syndrome and its components with -844 G/A and HindIII C/G PAI-1 gene polymorphisms in Mexican children.

    PubMed

    De la Cruz-Mosso, Ulises; Muñoz-Valle, José F; Salgado-Goytia, Lorenzo; García-Carreón, Adrián; Illades-Aguiar, Berenice; Castañeda-Saucedo, Eduardo; Parra-Rojas, Isela

    2012-03-29

    Several association studies have shown that -844 G/A and HindIII C/G PAI-1 polymorphisms are related with increase of PAI-1 levels, obesity, insulin resistance, glucose intolerance, hypertension and dyslipidemia, which are components of metabolic syndrome. The aim of this study was to analyze the allele and genotype frequencies of these polymorphisms in PAI-1 gene and its association with metabolic syndrome and its components in a sample of Mexican mestizo children. This study included 100 children with an age range between 6-11 years divided in two groups: a) 48 children diagnosed with metabolic syndrome and b) 52 children metabolically healthy without any clinical and biochemical alteration. Metabolic syndrome was defined as the presence of three or more of the following criteria: fasting glucose levels ≥ 100 mg/dL, triglycerides ≥ 150 mg/dL, HDL-cholesterol < 40 mg/dL, obesity BMI ≥ 95th percentile, systolic blood pressure (SBP) and diastolic blood pressure (DBP) ≥ 95th percentile and insulin resistance HOMA-IR ≥ 2.4. The -844 G/A and HindIII C/G PAI-1 polymorphisms were analyzed by PCR-RFLP. For the -844 G/A polymorphism, the G/A genotype (OR = 2.79; 95% CI, 1.11-7.08; p = 0.015) and the A allele (OR = 2.2; 95% CI, 1.10-4.43; p = 0.015) were associated with metabolic syndrome. The -844 G/A and A/A genotypes were associated with increase in plasma triglycerides levels (OR = 2.6; 95% CI, 1.16 to 6.04; p = 0.02), decrease in plasma HDL-cholesterol levels (OR = 2.4; 95% CI, 1.06 to 5.42; p = 0.03) and obesity (OR = 2.6; 95% CI, 1.17-5.92; p = 0.01). The C/G and G/G genotypes of the HindIII C/G polymorphism contributed to a significant increase in plasma total cholesterol levels (179 vs. 165 mg/dL; p = 0.02) in comparison with C/C genotype. The -844 G/A PAI-1 polymorphism is related with the risk of developing metabolic syndrome, obesity and atherogenic dyslipidemia, and the HindIII C/G PAI-1 polymorphism was associated with the increase of total

  10. SU-E-T-354: Peak Temperature Ratio of TLD Glow Curves to Investigate the Spatial Dependence of LET in a Clinical Proton Beam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reft, C; Pankuch, M; Ramirez, H

    Purpose: Use the ratio of the two high temperature peaks (HTR) in TLD 700 glow curves to investigate spatial dependence of the linear energy transfer (LET) in proton beams. Studies show that the relative biological effectiveness (RBE) depends upon the physical dose as well as its spatial distribution. Although proton therapy uses a spatially invariant RBE of 1.1, studies suggest that the RBE increases in the distal edge of a spread out Bragg peak (SOBP) due to the increased LET. Methods: Glow curve studies in TLD 700 show that the 280 C temperature peak is more sensitive to LET radiationmore » than the 210 C temperature peak. Therefore, the areas under the individual temperature peaks for TLDs irradiated in a proton beam normalized to the peak ratio for 6 MV photons are used to determine the HTR to obtain information on its LET. TLD 700 chips with dimensions 0.31×0.31×0.038 cc are irradiated with 90 MeV protons at varying depths in a specially designed blue wax phantom to investigate LET spatial dependence. Results: Five TLDs were placed at five different depths of the percent depth dose curve (PDD) of range 16.2 cm: center of the SOPB and approximately at the 99% distal edge, 90%, 75% and 25% of the PDD, respectively. HTR was 1.3 at the center of the SOBP and varied from 2.2 to 3.9 which can be related to an LET variation from 0.5 to 18 KeV/μ via calibration with radiation beams of varying LET. Conclusion: HTR data show a spatially invariant LET slightly greater than the 6 MV radiations in the SOBP, but a rapidly increasing LET at the end of the proton range. These results indicate a spatial variation in RBE with potential treatment consequences when selecting treatment margins to minimize the uncertainties in proton RBE.« less

  11. Technical Operations Support (TOPS) II. Delivery Order 0011: Summary Status of MISSE-1 and MISSE-2 Experiments and Details of Estimated Environmental Exposures for MISSE-1 and MISSE-2

    DTIC Science & Technology

    2006-07-01

    distinct types of devices were used that respond to radiation differently, TLDs (thermoluminescent dosimeters ), Charge-Coupled Devices (CCDs) and...optocouplers. The TLDs respond to total ionizing dose, most of which is contributed to by the trapped electrons for locations with less than 100 mils of... electrons , slab config. Space Station Calc., 1 yr dose, protons + electrons 7th TLD on W2-15 gave anomalously low reading BREB =Boeing Radiation

  12. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 2 Grants and Agreements 1 2012-01-01 2012-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of...

  13. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 2 Grants and Agreements 1 2014-01-01 2014-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of...

  14. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 2 Grants and Agreements 1 2013-01-01 2013-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of...

  15. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 2 Grants and Agreements 1 2011-01-01 2011-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of...

  16. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 2 Grants and Agreements 1 2010-01-01 2010-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a) Office of Management and...

  17. Measurements of occupational exposure for a technologist performing 18F FDG PET scans.

    PubMed

    Biran, Talma; Weininger, Jolie; Malchi, Shalom; Marciano, Rami; Chisin, Roland

    2004-11-01

    Radiation doses to one PET technologist performing 100 18F FDG (18F fluorodeoxyglucose) imaging procedures were measured in a clinical setting using two types of thermoluminescent dosimeter (TLD) badges, one finger-ring TLD and one electronic pocket dosimeter (EPD). 18F FDG was handled either with unshielded or with viewing window tungsten shielded syringes. The resulting doses using unshielded syringes were 13.8 +/- 0.8 microSv/370 MBq and 14.3 +/- 0.4 microSv/370 MBq, measured with TLD 100 and with TLD 700H/600H, respectively. For the same series of measurements, the doses obtained using shielded syringes were 10.7 +/- 0.4 microSv/370 MBq and 7.2 +/- 2.1 microSv/370 MBq with TLD700H/600H and with EPD, respectively. The dose to the right hand from shielded syringes was 69.3 +/- 5.5 microSv/370 MBq. All these values are within the ICRP recommended dose limits. Extrapolated to 725 examinations per year, the resulting effective dose measured with TLD would be 10 mSv with unshielded and 7.5 mSv with shielded syringes, respectively (25% dose reduction). The doses measured by TLD were consistently higher than those measured by EPD, suggesting that EPD measurements might underestimate occupational doses.

  18. Radiation mapping on Spacelab 1: Experiment no. INS006

    NASA Technical Reports Server (NTRS)

    Benton, E. V.; Frank, A.; Cassou, R.; Henke, R.; Rowe, V.

    1985-01-01

    The first attempt at mapping the radiation environment inside Spacelab is described. Measurements were made by a set of passive radiation detectors distributed throughout the volume inside the Spacelab 1 module, in the access tunnel and outside on the pallet. Measurements of the low linear energy transfer (LET) component obtained from the TLD thermoluminescent detectors (TLD) ranged from 92 to 134 mrad, yielding an average low LET dose rate of 10.0 mrads/day inside the module. Because of the higher inclination orbit, substantial fluxes of highly ionizing (HZE particles) high charge and energy galactic cosmic rays were observed for the first time on an STS flight, yielding an overall average mission dose-equivalent of 295 mrem, or 29.5 mrem/day, which is about three times higher than that measured on previous STS missions. Little correlation is found between measured average dose rates or HZE fluences and the estimates shielding throughout the volume of the module.

  19. Production of recombinant gG-1 protein of herpes simplex virus type 1 in a prokaryotic system in order to develop a type-specific enzyme-linked immunosorbent assay kit.

    PubMed

    Zandi, Keivan; Roostaee, Mohammad Hassan; Sadeghizadeh, Majid; Rasaee, Mohammad Javad; Sajedi, Reza Hassan; Soleimanjahi, Hoorieh

    2007-08-01

    The herpes simplex viruses are important causes of disease worldwide. Herpes simplex virus type 1 (HSV-1) is the primary cause of oral-facial and pharyngeal infections and may cause herpetic whitlow, eye infections as well as severe and sometimes dangerous infections of the eyes and brain. HSV-1 also accounts for 10-15% of all genital herpetic infections. Therefore, laboratory diagnosis of this virus and development of diagnostic serological techniques for HSV-1 is of particular importance. In the present study, pTrc His2A-gG1 plasmid, containing the full-length glycoprotein G (gG) protein, was produced in a prokaryotic system for the first time. Upon confirmation of a 37-kDa gG-1 protein production in a prokaryotic system based on western blotting and monoclonal antibodies, the protein was produced at a large scale and purified by ion-exchange chromatography using DEAE-sepharose. An HSV-1 type-specific diagnostic kit was designed and developed and the specificity and sensitivity of this kit were demonstrated to be 89.5% and 100%, respectively, as compared with a commercially available kit. A significant correlation was shown between the developed kit and the commercial kit.

  20. A 1.8K refrigeration cryostat with 100 hours continuous cooling

    NASA Astrophysics Data System (ADS)

    Xu, Dong; Li, Jian; Huang, Rongjin; Li, Laifeng

    2017-02-01

    A refrigeration cryostat has been developed to produce continuous cooling to a sample below 1.8 K over 100 hours by using a cryocooler. A two-stage 4K G-M cryocooler is used to liquefy helium gas from evacuated vapor and cylinder helium bottle which can be replaced during the cooling process. The liquid helium transfer into superfluid helium in a Joule-Thomson valve in connection with a 1000 m3/h pumping unit. The pressure of evacuated helium vapor is controlled by air bag and valves. A copper decompression chamber, which is designed as a cooling station to control the superfluid helium, is used to cool the sample attached on it uniformly. The sample connects to the copper chamber in cryostat with screw thread. The cryostat can reach the temperature of 1.7 K without load and the continuous working time is more than 100 hours.

  1. A weak lensing analysis of the PLCK G100.2-30.4 cluster

    NASA Astrophysics Data System (ADS)

    Radovich, M.; Formicola, I.; Meneghetti, M.; Bartalucci, I.; Bourdin, H.; Mazzotta, P.; Moscardini, L.; Ettori, S.; Arnaud, M.; Pratt, G. W.; Aghanim, N.; Dahle, H.; Douspis, M.; Pointecouteau, E.; Grado, A.

    2015-07-01

    We present a mass estimate of the Planck-discovered cluster PLCK G100.2-30.4, derived from a weak lensing analysis of deep Subaru griz images. We perform a careful selection of the background galaxies using the multi-band imaging data, and undertake the weak lensing analysis on the deep (1 h) r -band image. The shape measurement is based on the Kaiser-Squires-Broadhurst algorithm; we adopt the PSFex software to model the point spread function (PSF) across the field and correct for this in the shape measurement. The weak lensing analysis is validated through extensive image simulations. We compare the resulting weak lensing mass profile and total mass estimate to those obtained from our re-analysis of XMM-Newton observations, derived under the hypothesis of hydrostatic equilibrium. The total integrated mass profiles agree remarkably well, within 1σ across their common radial range. A mass M500 ~ 7 × 1014M⊙ is derived for the cluster from our weak lensing analysis. Comparing this value to that obtained from our reanalysis of XMM-Newton data, we obtain a bias factor of (1-b) = 0.8 ± 0.1. This is compatible within 1σ with the value of (1-b) obtained in Planck 2015 from the calibration of the bias factor using newly available weak lensing reconstructed masses. Based on data collected at Subaru Telescope (University of Tokyo).

  2. 4G/5G Polymorphism of the plasminogen activator inhibitor-1 gene is associated with multiple organ dysfunction in critically ill patients.

    PubMed

    Huq, Muhammad Aminul; Takeyama, Naoshi; Harada, Makoto; Miki, Yasuo; Takeuchi, Akinori; Inoue, Sousuke; Nakagawa, Takashi; Kanou, Hideki; Hirakawa, Akihiko; Noguchi, Hiroshi

    2012-01-01

    Impaired fibrinolysis is associated with a higher incidence of both multiple organ dysfunction and mortality in the intensive care unit (ICU). Plasminogen activator inhibitor (PAI)-1 is the chief inhibitor of fibrinolysis. We investigated the influence of the 4G/5G polymorphism (rs1799768) of the PAI-1 gene on the plasma PAI-1 level and the outcome of critically ill patients. In 41 consecutive patients admitted to the ICU, PAI-1 gene polymorphism was assessed, plasma PAI-1 and arterial lactate concentrations were measured and clinical severity scores were recorded. Homozygotes for the 4G allele had higher plasma levels of PAI-1 antigen. The mean ± SD PAI-1 antigen level was 193.31 ± 167.93 ng/ml for the 4G/4G genotype, 100.67 ± 114.16 ng/ml for the 4G/5G genotype and 0.43 ± 0.53 ng/ml for the 5G/5G genotype. There was a significant correlation between plasma PAI-1 and arterial lactate concentrations, as well as between PAI-1 and severity scores. The mortality rate was 63, 33 and 0% for patients with the 4G/4G, 4G/5G and 5G/5G genotypes, respectively. These results demonstrate that the 4G/5G polymorphism of the PAI-1 gene affects the plasma PAI-1 concentration, which could impair fibrinolysis and cause organ failure, and thus the presence of the 4G allele increases the risk of death. Copyright © 2011 S. Karger AG, Basel.

  3. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2012 CFR

    2009-01-01

    ... 2 Grants and Agreements 1 2009-01-01 2009-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a) Office...

  4. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2011 CFR

    2008-01-01

    ... 2 Grants and Agreements 1 2008-01-01 2008-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a) Office...

  5. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2011 CFR

    2005-01-01

    ... 2 Grants and Agreements 1 2005-01-01 2005-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a) Office...

  6. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2013 CFR

    2006-01-01

    ... 2 Grants and Agreements 1 2006-01-01 2006-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a) Office...

  7. 2 CFR 1.100 - Content of this title.

    Code of Federal Regulations, 2013 CFR

    2007-01-01

    ... 2 Grants and Agreements 1 2007-01-01 2007-01-01 false Content of this title. 1.100 Section 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a) Office...

  8. Lateral vibration behavior analysis and TLD vibration absorption design of the soft yoke single-point mooring system

    NASA Astrophysics Data System (ADS)

    Lyu, Bai-cheng; Wu, Wen-hua; Yao, Wei-an; Du, Yu

    2017-06-01

    Mooring system is the key equipment of FPSO safe operation. The soft yoke mooring system is regarded as one of the best shallow water mooring strategies and widely applied to the oil exploitation in the Bohai Bay in China and the Gulf of Mexico. Based on the analysis of numerous monitoring data obtained by the prototype monitoring system of one FPSO in the Bohai Bay, the on-site lateral vibration behaviors found on the site of the soft yoke subject to wave load were analyzed. ADAMS simulation and model experiment were utilized to analyze the soft yoke lateral vibration and it was determined that lateral vibration was resonance behaviors caused by wave excitation. On the basis of the soft yoke longitudinal restoring force being guaranteed, a TLD-based vibration damper system was constructed and the vibration reduction experiments with multi-tank space and multi-load conditions were developed. The experimental results demonstrated that the proposed TLD vibration reduction system can effectively reduce lateral vibration of soft yoke structures.

  9. REE Sorption Study of Seived -50 +100 Mesh Fraction of Media #1 in Brine #1 at Different Concentrations of REE at 70C

    DOE Data Explorer

    Gary Garland

    2015-06-29

    This dataset shows the sorption capacities of smaller grain size (-50 +100 mesh) of media #1 in brine #1 at different starting concentrations of REE's at elevated temperature of 70C. The experimental conditions are 2g of -50 +100 mesh media #1 to 150mL of REE solution at concentartions of .2ppm each, 2ppm each, and 20ppm each. The pH of the solution is 5.5, and the temperature was at 70C.

  10. An alternative method for immediate dose estimation using CaSO4:Dy based TLD badges

    NASA Astrophysics Data System (ADS)

    Singh, A. K.; Menon, S. N.; Dhabekar, Bhushan; Kadam, Sonal; Chougaonkar, M. P.; Babu, D. A. R.

    2014-11-01

    CaSO4:Dy based Thermoluminescence dosimeters (TLDs) are being used in country wide personnel monitoring program in India. The TL glow curve of CaSO4:Dy consists of a dosimetric peak at 220 °C and a low temperature peak at 120 °C which is unstable at room temperature. The TL integral counts in CaSO4:Dy reduces by 15% in seven days after irradiation due to the thermal fading of 120 °C TL peak. As the dosimetric procedure involves total integrated counts for dose conversion, the dosimeters are typically read about a week after receiving. However in the event of a suspected over exposure, where urgent processing is expected, this poses limitation. Post irradiation annealing treatment is used in such cases of immediate readout of cards. In this paper we report a new and easier to use technique based on optical bleaching for the urgent processing of TLD cards. Optical bleaching with green LED (∼555 nm photons) of 25,000 lux for one and half hour removes the low temperature TL peak without affecting the dosimetric peak. This method can be used for immediate dose estimation using CaSO4:Dy based TLD badges.

  11. Relationship of metabolic syndrome and its components with -844 G/A and HindIII C/G PAI-1 gene polymorphisms in Mexican children

    PubMed Central

    2012-01-01

    Background Several association studies have shown that -844 G/A and HindIII C/G PAI-1 polymorphisms are related with increase of PAI-1 levels, obesity, insulin resistance, glucose intolerance, hypertension and dyslipidemia, which are components of metabolic syndrome. The aim of this study was to analyze the allele and genotype frequencies of these polymorphisms in PAI-1 gene and its association with metabolic syndrome and its components in a sample of Mexican mestizo children. Methods This study included 100 children with an age range between 6-11 years divided in two groups: a) 48 children diagnosed with metabolic syndrome and b) 52 children metabolically healthy without any clinical and biochemical alteration. Metabolic syndrome was defined as the presence of three or more of the following criteria: fasting glucose levels ≥ 100 mg/dL, triglycerides ≥ 150 mg/dL, HDL-cholesterol < 40 mg/dL, obesity BMI ≥ 95th percentile, systolic blood pressure (SBP) and diastolic blood pressure (DBP) ≥ 95th percentile and insulin resistance HOMA-IR ≥ 2.4. The -844 G/A and HindIII C/G PAI-1 polymorphisms were analyzed by PCR-RFLP. Results For the -844 G/A polymorphism, the G/A genotype (OR = 2.79; 95% CI, 1.11-7.08; p = 0.015) and the A allele (OR = 2.2; 95% CI, 1.10-4.43; p = 0.015) were associated with metabolic syndrome. The -844 G/A and A/A genotypes were associated with increase in plasma triglycerides levels (OR = 2.6; 95% CI, 1.16 to 6.04; p = 0.02), decrease in plasma HDL-cholesterol levels (OR = 2.4; 95% CI, 1.06 to 5.42; p = 0.03) and obesity (OR = 2.6; 95% CI, 1.17-5.92; p = 0.01). The C/G and G/G genotypes of the HindIII C/G polymorphism contributed to a significant increase in plasma total cholesterol levels (179 vs. 165 mg/dL; p = 0.02) in comparison with C/C genotype. Conclusions The -844 G/A PAI-1 polymorphism is related with the risk of developing metabolic syndrome, obesity and atherogenic dyslipidemia, and the HindIII C/G PAI-1 polymorphism was

  12. 26 CFR 1.475(g)-1 - Effective dates.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 6 2012-04-01 2012-04-01 false Effective dates. 1.475(g)-1 Section 1.475(g)-1...) INCOME TAXES (CONTINUED) Inventories § 1.475(g)-1 Effective dates. (a)-(b) [Reserved] (c) Section 1.475(a...) applies on and after August 13, 1996 (the effective date of § 1.1275-6). (g) [Reserved] (h) Section 1.475...

  13. 26 CFR 1.475(g)-1 - Effective dates.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 6 2014-04-01 2014-04-01 false Effective dates. 1.475(g)-1 Section 1.475(g)-1...) INCOME TAXES (CONTINUED) Inventories § 1.475(g)-1 Effective dates. (a)-(b) [Reserved] (c) Section 1.475(a...) applies on and after August 13, 1996 (the effective date of § 1.1275-6). (g) [Reserved] (h) Section 1.475...

  14. 26 CFR 1.475(g)-1 - Effective dates.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 6 2013-04-01 2013-04-01 false Effective dates. 1.475(g)-1 Section 1.475(g)-1...) INCOME TAXES (CONTINUED) Inventories § 1.475(g)-1 Effective dates. (a)-(b) [Reserved] (c) Section 1.475(a...) applies on and after August 13, 1996 (the effective date of § 1.1275-6). (g) [Reserved] (h) Section 1.475...

  15. 26 CFR 1.475(g)-1 - Effective dates.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 6 2011-04-01 2011-04-01 false Effective dates. 1.475(g)-1 Section 1.475(g)-1...) INCOME TAXES (CONTINUED) Inventories § 1.475(g)-1 Effective dates. (a)-(b) [Reserved] (c) Section 1.475(a...) applies on and after August 13, 1996 (the effective date of § 1.1275-6). (g) [Reserved] (h) Section 1.475...

  16. 26 CFR 1.149(g)-1 - Hedge bonds.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 2 2012-04-01 2012-04-01 false Hedge bonds. 1.149(g)-1 Section 1.149(g)-1...) INCOME TAXES (CONTINUED) Tax Exemption Requirements for State and Local Bonds § 1.149(g)-1 Hedge bonds... for purposes of section 149(g) and this section. In addition, the following terms have the following...

  17. 26 CFR 1.149(g)-1 - Hedge bonds.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 2 2014-04-01 2014-04-01 false Hedge bonds. 1.149(g)-1 Section 1.149(g)-1...) INCOME TAXES (CONTINUED) Tax Exemption Requirements for State and Local Bonds § 1.149(g)-1 Hedge bonds... for purposes of section 149(g) and this section. In addition, the following terms have the following...

  18. 26 CFR 1.149(g)-1 - Hedge bonds.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 2 2011-04-01 2011-04-01 false Hedge bonds. 1.149(g)-1 Section 1.149(g)-1...) INCOME TAXES (CONTINUED) Tax Exemption Requirements for State and Local Bonds § 1.149(g)-1 Hedge bonds... for purposes of section 149(g) and this section. In addition, the following terms have the following...

  19. 26 CFR 1.149(g)-1 - Hedge bonds.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 2 2013-04-01 2013-04-01 false Hedge bonds. 1.149(g)-1 Section 1.149(g)-1...) INCOME TAXES (CONTINUED) Tax Exemption Requirements for State and Local Bonds § 1.149(g)-1 Hedge bonds... for purposes of section 149(g) and this section. In addition, the following terms have the following...

  20. 26 CFR 1.149(g)-1 - Hedge bonds.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Hedge bonds. 1.149(g)-1 Section 1.149(g)-1...) INCOME TAXES (CONTINUED) Tax Exemption Requirements for State and Local Bonds § 1.149(g)-1 Hedge bonds... for purposes of section 149(g) and this section. In addition, the following terms have the following...

  1. Predominate HIV1-specific IgG activity in various mucosal compartments of HIV1-infected individuals.

    PubMed

    Lü, F X

    2000-10-01

    Evaluating mucosal humoral immunity is important for understanding local immunity induced by HIV infection or vaccination and designing prophylactic strategies. To characterize the mucosal humoral immunity following HIV infection, the levels of immunoglobulins (Igs), antibodies (Abs), and HIV1-specific Ab activity were evaluated in cervicovaginal secretions (CVS), saliva, breast milk, and sera of HIV-infected individuals. HIV1-specific IgG activity was significantly higher than that of IgA in CVS, saliva, and breast milk. The highest HIV1-specific IgG activity was found in breast milk. The data suggest that anti-HIV1 Abs in CVS were most likely serum derived. However, HIV1-specific Abs in saliva and breast milk were mainly locally produced. The prevalence of HIV1-specific Abs in seropositive subjects was 97% for IgG and 95% for IgA in CVS, 100% for IgG and 80% for IgA in saliva, and 59% for IgG and 94% for IgA in breast milk. These data provide evidence for both a better understanding of the nature of humoral mucosal responses after HIV1 infection and the development of strategies to induce desirable functional mucosal immunity for preventing HIV transmission. Copyright 2000 Academic Press.

  2. Digital geologic map of part of the Thompson Falls 1:100,000 quadrangle, Idaho

    USGS Publications Warehouse

    Lewis, Reed S.; Derkey, Pamela D.

    1999-01-01

    The geology of the Thompson Falls 1:100,000 quadrangle, Idaho was compiled by Reed S. Lewis in 1997 onto a 1:100,000-scale greenline mylar of the topographic base map for input into a geographic information system (GIS). The resulting digital geologic map GIS can be queried in many ways to produce a variety of geologic maps. Digital base map data files (topography, roads, towns, rivers and lakes, etc.) are not included: they may be obtained from a variety of commercial and government sources. This database is not meant to be used or displayed at any scale larger than 1:100,000 (e.g., 1:62,500 or 1:24,000). The map area is located in north Idaho. This open-file report describes the geologic map units, the methods used to convert the geologic map data into a digital format, the Arc/Info GIS file structures and relationships, and explains how to download the digital files from the U.S. Geological Survey public access World Wide Web site on the Internet.

  3. MO-A-BRB-01: TG191: Clinical Use of Luminescent Dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kry, S.

    This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3)more » To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.« less

  4. MO-A-BRB-00: TG191: Clinical Use of Luminescent Dosimeters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    This presentation will highlight the upcoming TG-191 report: Clinical Use of Luminescent Dosimeters. Luminescent dosimetry based on TLD and OSLD is a practical, accurate, and precise technique for point dosimetry in medical physics applications. The charges of Task Group 191 were to detail the methodologies for practical and optimal luminescent dosimetry in a clinical setting. This includes (1) To review the variety of TLD/OSL materials available, including features and limitations of each. (2) To outline the optimal steps to achieve accurate and precise dosimetry with luminescent detectors and to evaluate the uncertainty induced when less rigorous procedures are used. (3)more » To develop consensus guidelines on the optimal use of luminescent dosimeters for clinical practice. (4) To develop guidelines for special medically relevant uses of TLDs/OSLs (e.g., mixed field i.e. photon/neutron dosimetry, particle beam dosimetry, skin dosimetry). While this report provides general guidelines for arbitrary TLD and OSLD processes, the report, and therefore this presentation, provide specific guidance for TLD-100 (LiF:Ti,Mg) and nanoDot (Al2O3:C) dosimeters because of their prevalence in clinical practice. Learning Objectives: Understand the available dosimetry systems, and basic theory of their operation Understand the range of dose determination methodologies and the uncertainties associated with them Become familiar with special considerations for TLD/OSLD relevant for special clinical situations Learn recommended commissioning and QA procedures for these dosimetry systems.« less

  5. On the effect of updated MCNP photon cross section data on the simulated response of the HPA TLD.

    PubMed

    Eakins, Jonathan

    2009-02-01

    The relative response of the new Health Protection Agency thermoluminescence dosimeter (TLD) has been calculated for Narrow Series X-ray distribution and (137)Cs photon sources using the Monte Carlo code MCNP5, and the results compared with those obtained during its design stage using the predecessor code, MCNP4c2. The results agreed at intermediate energies (approximately 0.1 MeV to (137)Cs), but differed at low energies (<0.1 MeV) by up to approximately 10%. This disparity has been ascribed to differences in the default photon interaction data used by the two codes, and derives ultimately from the effect on absorbed dose of the recent updates to the photoelectric cross sections. The sources of these data have been reviewed.

  6. Significant contribution of subtype G to HIV-1 genetic complexity in Nigeria identified by a newly developed subtyping assay specific for subtype G and CRF02_AG

    PubMed Central

    Heipertz, Richard A.; Ayemoba, Ojor; Sanders-Buell, Eric; Poltavee, Kultida; Pham, Phuc; Kijak, Gustavo H.; Lei, Esther; Bose, Meera; Howell, Shana; O'Sullivan, Anne Marie; Bates, Adam; Cervenka, Taylor; Kuroiwa, Janelle; Akintunde, Akindiran; Ibezim, Onyekachukwu; Alabi, Abraham; Okoye, Obumneke; Manak, Mark; Malia, Jennifer; Peel, Sheila; Maisaka, Mohammed; Singer, Darrell; O’Connell, Robert J.; Robb, Merlin L.; Kim, Jerome H.; Michael, Nelson L.; Njoku, Ogbonnaya; Tovanabutra, Sodsai

    2016-01-01

    Abstract While abundant sequence information is available from human immunodeficiency virus type 1 (HIV-1) subtypes A, B, C and CRF01_AE for HIV-1 vaccine design, sequences from West Africa are less represented. We sought to augment our understanding of HIV-1 variants circulating in 6 Nigerian cities as a step to subsequent HIV-1 vaccine development. The G/CRF02_AG multi-region hybridization assay (MHA) was developed to differentiate subtype G, CRF02_AG and their recombinants from other subtypes based on 7 HIV-1 segments. Plasma from 224 HIV-1 infected volunteers enrolled in a cohort examining HIV-1 prevalence, risk factor, and subtype from Makurdi (30), Abuja (18), Enugu (11), Kaduna (12), Tafa (95), and Ojo/Lagos (58) was analyzed using MHA. HIV-1 genomes from 42 samples were sequenced to validate the MHA and fully explore the recombinant structure of G and CRF02_AG variants. The sensitivity and specificity of MHA varied between 73–100% and 90–100%, respectively. The subtype distribution as identified by MHA among 224 samples revealed 38% CRF02_AG, 28% G, and 26% G/CRF02_AG recombinants while 8% remained nontypeable strains. In envelope (env) gp120, 38.84% of the samples reacted to a G probe while 31.25% reacted to a CRF02 (subtype A) probe. Full genome characterization of 42 sequences revealed the complexity of Nigerian HIV-1 variants. CRF02_AG, subtype G, and their recombinants were the major circulating HIV-1 variants in 6 Nigerian cities. High proportions of samples reacted to a G probe in env gp120 confirms that subtype G infections are abundant and should be considered in strategies for global HIV-1 vaccine development. PMID:27512845

  7. Inflammation and pancreatic cancer: molecular and functional interactions between S100A8, S100A9, NT-S100A8 and TGFβ1

    PubMed Central

    2014-01-01

    Background In order to gain further insight on the crosstalk between pancreatic cancer (PDAC) and stromal cells, we investigated interactions occurring between TGFβ1 and the inflammatory proteins S100A8, S100A9 and NT-S100A8, a PDAC-associated S100A8 derived peptide, in cell signaling, intracellular calcium (Cai2+) and epithelial to mesenchymal transition (EMT). NF-κB, Akt and mTOR pathways, Cai2+ and EMT were studied in well (Capan1 and BxPC3) and poorly differentiated (Panc1 and MiaPaCa2) cell lines. Results NT-S100A8, one of the low molecular weight N-terminal peptides from S100A8 to be released by PDAC-derived proteases, shared many effects on NF-κB, Akt and mTOR signaling with S100A8, but mainly with TGFβ1. The chief effects of S100A8, S100A9 and NT-S100A8 were to inhibit NF-κB and stimulate mTOR; the molecules inhibited Akt in Smad4-expressing, while stimulated Akt in Smad4 negative cells. By restoring Smad4 expression in BxPC3 and silencing it in MiaPaCa2, S100A8 and NT-S100A8 were shown to inhibit NF-κB and Akt in the presence of an intact TGFβ1 canonical signaling pathway. TGFβ1 counteracted S100A8, S100A9 and NT-S100A8 effects in Smad4 expressing, not in Smad4 negative cells, while it synergized with NT-S100A8 in altering Cai2+ and stimulating PDAC cell growth. The effects of TGFβ1 on both EMT (increased Twist and decreased N-Cadherin expression) and Cai2+ were antagonized by S100A9, which formed heterodimers with TGFβ1 (MALDI-TOF/MS and co-immuno-precipitation). Conclusions The effects of S100A8 and S100A9 on PDAC cell signaling appear to be cell-type and context dependent. NT-S100A8 mimics the effects of TGFβ1 on cell signaling, and the formation of complexes between TGFβ1 with S100A9 appears to be the molecular mechanism underlying the reciprocal antagonism of these molecules on cell signaling, Cai2+ and EMT. PMID:24670043

  8. Inflammation and pancreatic cancer: molecular and functional interactions between S100A8, S100A9, NT-S100A8 and TGFβ1.

    PubMed

    Basso, Daniela; Bozzato, Dania; Padoan, Andrea; Moz, Stefania; Zambon, Carlo-Federico; Fogar, Paola; Greco, Eliana; Scorzeto, Michele; Simonato, Francesca; Navaglia, Filippo; Fassan, Matteo; Pelloso, Michela; Dupont, Sirio; Pedrazzoli, Sergio; Fassina, Ambrogio; Plebani, Mario

    2014-03-26

    In order to gain further insight on the crosstalk between pancreatic cancer (PDAC) and stromal cells, we investigated interactions occurring between TGFβ1 and the inflammatory proteins S100A8, S100A9 and NT-S100A8, a PDAC-associated S100A8 derived peptide, in cell signaling, intracellular calcium (Cai2+) and epithelial to mesenchymal transition (EMT). NF-κB, Akt and mTOR pathways, Cai2+ and EMT were studied in well (Capan1 and BxPC3) and poorly differentiated (Panc1 and MiaPaCa2) cell lines. NT-S100A8, one of the low molecular weight N-terminal peptides from S100A8 to be released by PDAC-derived proteases, shared many effects on NF-κB, Akt and mTOR signaling with S100A8, but mainly with TGFβ1. The chief effects of S100A8, S100A9 and NT-S100A8 were to inhibit NF-κB and stimulate mTOR; the molecules inhibited Akt in Smad4-expressing, while stimulated Akt in Smad4 negative cells. By restoring Smad4 expression in BxPC3 and silencing it in MiaPaCa2, S100A8 and NT-S100A8 were shown to inhibit NF-κB and Akt in the presence of an intact TGFβ1 canonical signaling pathway. TGFβ1 counteracted S100A8, S100A9 and NT-S100A8 effects in Smad4 expressing, not in Smad4 negative cells, while it synergized with NT-S100A8 in altering Cai2+ and stimulating PDAC cell growth. The effects of TGFβ1 on both EMT (increased Twist and decreased N-Cadherin expression) and Cai2+ were antagonized by S100A9, which formed heterodimers with TGFβ1 (MALDI-TOF/MS and co-immuno-precipitation). The effects of S100A8 and S100A9 on PDAC cell signaling appear to be cell-type and context dependent. NT-S100A8 mimics the effects of TGFβ1 on cell signaling, and the formation of complexes between TGFβ1 with S100A9 appears to be the molecular mechanism underlying the reciprocal antagonism of these molecules on cell signaling, Cai2+ and EMT.

  9. Effects of 2.0-g 1.75-g and 1.5-g Hypergravity on Pregnancy Outcome in Rats (Rattus norvegicus)

    NASA Technical Reports Server (NTRS)

    Mills, Nicole A.; Baer, Lisa A.; Ronca, April E.

    2001-01-01

    In 1995, ten pregnant female rats were launched on the Space Shuttle (STS-70) on Gestational day(G) 11 of their 22-day pregnancy as part of the NASA/NIH.Rodent (R)2 Experiment. Following landing on G20, fetuses were harvested from half of the dams, while the remaining five dams underwent birth. Spaceflight did not interrupt pregnancy, alter litter sizes, or affect body weights or gender ratios of the fetuses or neonates. In the present study we used the NASA/NIH.R2 experimental paradigm to analyze the effects of hypergravity on pregnancy outcome. On G10, time-bred Sprague-Dawley rat dams were assigned to either G20 or Birth conditions, then further assigned to Hypergravity (HG) 2.0-g, HG 1.75-g, HG 1.5-g, Rotational Control (RC, 1.03), or Stationary Control (SC, 1.0-g) treatments. Dams were exposed to continuous centrifugation from G11 through G20, with brief daily stops for animal health checks and maintenance. For both the G20 and Birth dams, comparable litter sizes and litter gender ratios were observed across gravity conditions. However, centrifugation-exposed (HG and RC) fetuses and neonates showed significantly lower body masses (p less than 0.05) relative to SC offspring. HG 2.0-g offspring weighed significantly less than those in all other gravity conditions (p less than 0.05). The observed reductions in offspring body mass at 1.5-g and 1.75-g, can be attributed to the rotational component of centrifugation, rather than to increased gravitational load, whereas 2.0-g hypergravity exposure further exacerbated the gravity centrifugation effect on offspring body mass. Pregnant dams exposed to centrifugation weighed significantly less than SC dams (p less than 0.05), suggesting that centrifugation effects on maternal body mass may contribute to reduced size of the developing offspring. These findings are consistent with previous reports of non-pregnant adult animals suggesting that, whereas spaceflight has virtually no effect on body mass, centrifugation is

  10. REE Sorption Study of Sieved -50 +100 mesh Media #1 in Brine #1 with Different Starting pH's at 70C

    DOE Data Explorer

    Gary Garland

    2015-07-21

    This dataset described shaker table experiments ran with sieved -50 +100 mesh media #1 in brine #1 that have 2ppm each of the 7 REE metals at different starting pH's of 3.5, 4.5, and 5.5. The experimental conditions are 2g media to 150mL of REE solution, at 70C.

  11. 100-D Ponds closure plan. Revision 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Petersen, S.W.

    1997-09-01

    The 100-D Ponds is a Treatment, Storage, and Disposal (TSD) unit on the Hanford Facility that received both dangerous and nonregulated waste. This Closure Plan (Rev. 1) for the 100-D Ponds TSD unit consists of a RCRA Part A Dangerous Waste Permit Application (Rev. 3), a RCRA Closure Plan, and supporting information contained in the appendices to the plan. The closure plan consists of eight chapters containing facility description, process information, waste characteristics, and groundwater monitoring data. There are also chapters containing the closure strategy and performance standards. The strategy for the closure of the 100-D Ponds TSD unit ismore » clean closure. Appendices A and B of the closure plan demonstrate that soil and groundwater beneath 100-D Ponds are below cleanup limits. All dangerous wastes or dangerous waste constituents or residues associated with the operation of the ponds have been removed, therefore, human health and the environment are protected. Discharges to the 100-D Ponds, which are located in the 100-DR-1 operable unit, were discontinued in June 1994. Contaminated sediment was removed from the ponds in August 1996. Subsequent sampling and analysis demonstrated that there is no contamination remaining in the ponds, therefore, this closure plan is a demonstration of clean closure.« less

  12. Neutron measurement at the thermal column of the Malaysian Triga Mark II reactor using gold foil activation method and TLD

    NASA Astrophysics Data System (ADS)

    Shalbi, Safwan; Salleh, Wan Norhayati Wan; Mohamad Idris, Faridah; Aliff Ashraff Rosdi, Muhammad; Syahir Sarkawi, Muhammad; Liyana Jamsari, Nur; Nasir, Nur Aishah Mohd

    2018-01-01

    In order to design facilities for boron neutron capture therapy (BNCT), the neutron measurement must be considered to obtain the optimal design of BNCT facility such as collimator and shielding. The previous feasibility study showed that the thermal column could generate higher thermal neutrons yield for BNCT application at the TRIGA MARK II reactor. Currently, the facility for BNCT are planned to be developed at thermal column. Thus, the main objective was focused on the thermal neutron and epithermal neutron flux measurement at the thermal column. In this measurement, pure gold and cadmium were used as a filter to obtain the thermal and epithermal neutron fluxes from inside and outside of the thermal column door of the 200kW reactor power using a gold foil activation method. The results were compared with neutron fluxes using TLD 600 and TLD 700. The outcome of this work will become the benchmark for the design of BNCT collimator and the shielding

  13. Vildagliptin and its metabolite M20.7 induce the expression of S100A8 and S100A9 in human hepatoma HepG2 and leukemia HL-60 cells

    PubMed Central

    Asakura, Mitsutoshi; Karaki, Fumika; Fujii, Hideaki; Atsuda, Koichiro; Itoh, Tomoo; Fujiwara, Ryoichi

    2016-01-01

    Vildagliptin is a potent, orally active inhibitor of dipeptidyl peptidase-4 (DPP-4) for the treatment of type 2 diabetes mellitus. It has been reported that vildagliptin can cause hepatic dysfunction in patients. However, the molecular-mechanism of vildagliptin-induced liver dysfunction has not been elucidated. In this study, we employed an expression microarray to determine hepatic genes that were highly regulated by vildagliptin in mice. We found that pro-inflammatory S100 calcium-binding protein (S100) a8 and S100a9 were induced more than 5-fold by vildagliptin in the mouse liver. We further examined the effects of vildagliptin and its major metabolite M20.7 on the mRNA expression levels of S100A8 and S100A9 in human hepatoma HepG2 and leukemia HL-60 cells. In HepG2 cells, vildagliptin, M20.7, and sitagliptin – another DPP-4 inhibitor – induced S100A9 mRNA. In HL-60 cells, in contrast, S100A8 and S100A9 mRNAs were significantly induced by vildagliptin and M20.7, but not by sitagliptin. The release of S100A8/A9 complex in the cell culturing medium was observed in the HL-60 cells treated with vildagliptin and M20.7. Therefore, the parental vildagliptin- and M20.7-induced release of S100A8/A9 complex from immune cells, such as neutrophils, might be a contributing factor of vildagliptin-associated liver dysfunction in humans. PMID:27759084

  14. Vildagliptin and its metabolite M20.7 induce the expression of S100A8 and S100A9 in human hepatoma HepG2 and leukemia HL-60 cells.

    PubMed

    Asakura, Mitsutoshi; Karaki, Fumika; Fujii, Hideaki; Atsuda, Koichiro; Itoh, Tomoo; Fujiwara, Ryoichi

    2016-10-19

    Vildagliptin is a potent, orally active inhibitor of dipeptidyl peptidase-4 (DPP-4) for the treatment of type 2 diabetes mellitus. It has been reported that vildagliptin can cause hepatic dysfunction in patients. However, the molecular-mechanism of vildagliptin-induced liver dysfunction has not been elucidated. In this study, we employed an expression microarray to determine hepatic genes that were highly regulated by vildagliptin in mice. We found that pro-inflammatory S100 calcium-binding protein (S100) a8 and S100a9 were induced more than 5-fold by vildagliptin in the mouse liver. We further examined the effects of vildagliptin and its major metabolite M20.7 on the mRNA expression levels of S100A8 and S100A9 in human hepatoma HepG2 and leukemia HL-60 cells. In HepG2 cells, vildagliptin, M20.7, and sitagliptin - another DPP-4 inhibitor - induced S100A9 mRNA. In HL-60 cells, in contrast, S100A8 and S100A9 mRNAs were significantly induced by vildagliptin and M20.7, but not by sitagliptin. The release of S100A8/A9 complex in the cell culturing medium was observed in the HL-60 cells treated with vildagliptin and M20.7. Therefore, the parental vildagliptin- and M20.7-induced release of S100A8/A9 complex from immune cells, such as neutrophils, might be a contributing factor of vildagliptin-associated liver dysfunction in humans.

  15. Application and expression of HSV gG1 protein from a recombinant strain.

    PubMed

    Yan, Hua; Yan, Huishen; Huang, Tao; Li, Guocai; Gong, Weijuan; Jiao, Hongmei; Chen, Hongju; Ji, Mingchun

    2010-11-01

    According to the homologous sequence of glycoprotein G1 (gG1) genes from different strains of herpes simplex virus type 1 (HSV-1), a pair of primers was designed to amplify the gG1 gene fragment by PCR. Both the PCR product and the pGEX-4T-1 vector were digested with EcoR I and Sal I. The gG1 gene fragment was subcloned into the digested pGEX-4T-1 vector to construct a recombinant plasmid (pGEX-4T-1-gG1). The resultant plasmid was identified by dual-enzyme digestion and sequence analysis, and then transformed into Escherichia coli BL21 for expression under the induction of isopropyl β-D-1-thiogalactoside (IPTG). The expressed GST-gG1 fragment was detected by SDS-PAGE and purified by affinity chromatography. The properties of GST-gG1 fragment were evaluated by immunoblot analysis. Enzyme-linked immunosorbent assays (ELISAs) based on the GST-gG1 fragment were used for determining IgG or IgM to HSV-1. The GST-gG1 fragment-specific ELISA was also compared with ELISA with whole-HSV-1 antigen and commercial ELISA kits. The gG1-specific IgG and IFN-γ producing CD8+ T cells were induced in mice immunized with the GST-gG1 fragment. These results indicated that the GST-gG1 fragment could be used for replacing whole-virus antigen to detect IgM and IgG to HSV-1 in human sera, which provided a strategy for developing vaccines to protect HSV-1 infection using gG1 fragment. Copyright © 2010 Elsevier B.V. All rights reserved.

  16. Molecular basis for the interaction between stress-inducible phosphoprotein 1 (STIP1) and S100A1.

    PubMed

    Maciejewski, Andrzej; Prado, Vania F; Prado, Marco A M; Choy, Wing-Yiu

    2017-05-16

    Stress-inducible phosphoprotein 1 (STIP1) is a cellular co-chaperone, which regulates heat-shock protein 70 (Hsp70) and Hsp90 activity during client protein folding. Members of the S100 family of dimeric calcium-binding proteins have been found to inhibit Hsp association with STIP1 through binding of STIP1 tetratricopeptide repeat (TPR) domains, possibly regulating the chaperone cycle. Here, we investigated the molecular basis of S100A1 binding to STIP1. We show that three S100A1 dimers associate with one molecule of STIP1 in a calcium-dependent manner. Isothermal titration calorimetry revealed that individual STIP1 TPR domains, TPR1, TPR2A and TPR2B, bind a single S100A1 dimer with significantly different affinities and that the TPR2B domain possesses the highest affinity for S100A1. S100A1 bound each TPR domain through a common binding interface composed of α-helices III and IV of each S100A1 subunit, which is only accessible following a large conformational change in S100A1 upon calcium binding. The TPR2B-binding site for S100A1 was predominately mapped to the C-terminal α-helix of TPR2B, where it is inserted into the hydrophobic cleft of an S100A1 dimer, suggesting a novel binding mechanism. Our data present the structural basis behind STIP1 and S100A1 complex formation, and provide novel insights into TPR module-containing proteins and S100 family member complexes. © 2017 The Author(s); published by Portland Press Limited on behalf of the Biochemical Society.

  17. 17 CFR 240.12g-1 - Exemption from section 12(g).

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... pursuant to section 12(g)(1) if on the last day of its most recent fiscal year the issuer had total assets...). 240.12g-1 Section 240.12g-1 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION... Securities Exchange Act of 1934 Extensions and Temporary Exemptions; Definitions § 240.12g-1 Exemption from...

  18. 17 CFR 240.12g-1 - Exemption from section 12(g).

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... pursuant to section 12(g)(1) if on the last day of its most recent fiscal year the issuer had total assets...). 240.12g-1 Section 240.12g-1 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION... Securities Exchange Act of 1934 Extensions and Temporary Exemptions; Definitions § 240.12g-1 Exemption from...

  19. 17 CFR 240.12g-1 - Exemption from section 12(g).

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... pursuant to section 12(g)(1) if on the last day of its most recent fiscal year the issuer had total assets...). 240.12g-1 Section 240.12g-1 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION... Securities Exchange Act of 1934 Extensions and Temporary Exemptions; Definitions § 240.12g-1 Exemption from...

  20. 17 CFR 240.12g-1 - Exemption from section 12(g).

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... pursuant to section 12(g)(1) if on the last day of its most recent fiscal year the issuer had total assets...). 240.12g-1 Section 240.12g-1 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION... Securities Exchange Act of 1934 Extensions and Temporary Exemptions; Definitions § 240.12g-1 Exemption from...

  1. 17 CFR 240.12g-1 - Exemption from section 12(g).

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... pursuant to section 12(g)(1) if on the last day of its most recent fiscal year the issuer had total assets...). 240.12g-1 Section 240.12g-1 Commodity and Securities Exchanges SECURITIES AND EXCHANGE COMMISSION... Securities Exchange Act of 1934 Extensions and Temporary Exemptions; Definitions § 240.12g-1 Exemption from...

  2. Requirement of ClC-3 in G0/G1 to S Phase Transition Induced by IGF-1 via ERK1/2-Cyclins Cascade in Multiple Myeloma Cells.

    PubMed

    Du, Yu; Tu, Yong-Sheng; Tang, Yong-Bo; Huang, Yun-Ying; Zhou, Fang-Min; Tian, Tian; Li, Xiao-Yan

    2018-06-01

    ClC-3 is involved in the proliferation and migration of several cancer cells. However, ClC-3 expression and its role of cell-cycle control in multiple myeloma (MM) has not yet been investigated. MM cells were treated with different concentrations of IGF (30, 100, 300 ng/mL), and their proliferation was examined by CCK-8. The effects of ClC-3 on cell cycle progression was detected by flow cytometry. Western blot was used to analyze the relative levels of ClC3, CD138, P21, P27, CDK, p-Erk1/2, and t-Erk1/2 protein expression. Transfection of RPMI8226 with gpClC-3 cDNA and siRNA alters the expression of ClC-3. We compared the expression of ClC-3 in primary myeloma cells and in MM cell lines (U266 and RPMI8266) with that in normal plasma cells (PCs) from normal subjects and found that myeloma cells from patients and MM cell lines had significantly higher expression of ClC-3. Additionally, silencing of ClC-3 with the small interfering RNA (siRNA) that targets human ClC-3 decreased proliferation of RPMI8226 after IGF-1 treatment and slowed cell cycle progression from G0/G1 to S phase, which was associated with diminished phosphorylation of ERK1/2, down-expression of cyclin E, cyclin D1 and up-regulation of p27 and p21. By contrast, overexpression of ClC-3 potentiated cell proliferation induced by IGF-1, raised the percentage of S phase cells, enhanced phosphorylation of ERK1/2, downregulated p27 and p21 and upregulated cyclin E and cyclin D1. ClC-3 accelerated G0/G1 to S phase transition in the cell cycle by modulating ERK1/2 kinase activity and expression of G1/S transition related proteins, making ClC-3 an attractive therapeutic target in MM.

  3. 12 CFR 747.100 - Discovery limitations.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 7 2014-01-01 2014-01-01 false Discovery limitations. 747.100 Section 747.100... Practice and Procedure § 747.100 Discovery limitations. (a) Parties to a proceeding set forth either at § 747.1 of subpart A or in subpart C, E or G of this part may obtain discovery only through the...

  4. 12 CFR 747.100 - Discovery limitations.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 12 Banks and Banking 7 2012-01-01 2012-01-01 false Discovery limitations. 747.100 Section 747.100... Practice and Procedure § 747.100 Discovery limitations. (a) Parties to a proceeding set forth either at § 747.1 of subpart A or in subpart C, E or G of this part may obtain discovery only through the...

  5. 12 CFR 747.100 - Discovery limitations.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 12 Banks and Banking 7 2013-01-01 2013-01-01 false Discovery limitations. 747.100 Section 747.100... Practice and Procedure § 747.100 Discovery limitations. (a) Parties to a proceeding set forth either at § 747.1 of subpart A or in subpart C, E or G of this part may obtain discovery only through the...

  6. 12 CFR 747.100 - Discovery limitations.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Discovery limitations. 747.100 Section 747.100... Practice and Procedure § 747.100 Discovery limitations. (a) Parties to a proceeding set forth either at § 747.1 of subpart A or in subpart C, E or G of this part may obtain discovery only through the...

  7. 41 CFR 105-1.100 - Scope of subpart.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Scope of subpart. 105-1.100 Section 105-1.100 Public Contracts and Property Management Federal Property Management Regulations... Scope of subpart. This subpart establishes the General Services Administration Property Management...

  8. 41 CFR 105-1.100 - Scope of subpart.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Scope of subpart. 105-1.100 Section 105-1.100 Public Contracts and Property Management Federal Property Management Regulations... Scope of subpart. This subpart establishes the General Services Administration Property Management...

  9. 41 CFR 105-1.100 - Scope of subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Scope of subpart. 105-1.100 Section 105-1.100 Public Contracts and Property Management Federal Property Management Regulations... Scope of subpart. This subpart establishes the General Services Administration Property Management...

  10. 41 CFR 105-1.100 - Scope of subpart.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Scope of subpart. 105-1.100 Section 105-1.100 Public Contracts and Property Management Federal Property Management Regulations... Scope of subpart. This subpart establishes the General Services Administration Property Management...

  11. 41 CFR 105-1.100 - Scope of subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Scope of subpart. 105-1.100 Section 105-1.100 Public Contracts and Property Management Federal Property Management Regulations... Scope of subpart. This subpart establishes the General Services Administration Property Management...

  12. 2 CFR § 1.100 - Content of this title.

    Code of Federal Regulations, 2012 CFR

    2017-01-01

    ... 2 Grants and Agreements 1 2017-01-01 2017-01-01 false Content of this title. § 1.100 Section § 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a)...

  13. 2 CFR § 1.100 - Content of this title.

    Code of Federal Regulations, 2013 CFR

    2016-01-01

    ... 2 Grants and Agreements 1 2016-01-01 2016-01-01 false Content of this title. § 1.100 Section § 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a)...

  14. 2 CFR § 1.100 - Content of this title.

    Code of Federal Regulations, 2010 CFR

    2018-01-01

    ... 2 Grants and Agreements 1 2018-01-01 2018-01-01 false Content of this title. § 1.100 Section § 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a)...

  15. 2 CFR § 1.100 - Content of this title.

    Code of Federal Regulations, 2011 CFR

    2015-01-01

    ... 2 Grants and Agreements 1 2015-01-01 2015-01-01 false Content of this title. § 1.100 Section § 1.100 Grants and Agreements Office of Management and Budget Guidance for Grants and Agreements ABOUT TITLE 2 OF THE CODE OF FEDERAL REGULATIONS AND SUBTITLE A Introduction to Title 2 of the CFR § 1.100 Content of this title. This title contains— (a)...

  16. Efficacy of antipsychotic agents at human 5-HT(1A) receptors determined by [3H]WAY100,635 binding affinity ratios: relationship to efficacy for G-protein activation.

    PubMed

    Newman-Tancredi, A; Verrièle, L; Touzard, M; Millan, M J

    2001-10-05

    5-HT(1A) receptors are implicated in the aetiology of schizophrenia. Herein, the influence of 15 antipsychotics on the binding of the selective 'neutral' antagonist, [3H]WAY100,635 ([3H]N-[2-[4-(2-methoxyphenyl)-1-piperazinyl]ethyl]-N-(2-pyridinyl)-cyclo-hexanecarboxamide), was examined at human 5-HT(1A) receptors expressed in Chinese Hamster Ovary cells. In competition binding experiments, 5-HT displayed biphasic isotherms which were shifted to the right in the presence of the G-protein uncoupling agent, GTPgammaS (100 microM). In analogy, the isotherms of ziprasidone, quetiapine and S16924 (((R-2-[1-[2-(2,3-dihydro-benzo[1,4]dioxin-5-yloxy)-ethyl]-pyrrolidin-3yl]-1-(4-fluoro-phenyl)-ethanone), were displaced to the right by GTPgammaS, consistent with agonist actions. Binding of several other antipsychotics, such as ocaperidone, olanzapine and risperidone, was little influenced by GTPgammaS. Isotherms of the neuroleptics, haloperidol, chlorpromazine and thioridazine were shifted to the left in the presence of GTPgammaS, suggesting inverse agonist properties. For most ligands, the magnitude of affinity changes induced by GTPgammaS (alteration in pK(i) values) correlated well with their previously determined efficacies in [35S]GTPgammaS binding studies [Eur. J. Pharmacol. 355 (1998) 245]. In contrast, the affinity of the 'atypical' antipsychotic agent, clozapine, which is a known partial agonist at 5-HT(1A) receptors, was less influenced by GTPgammaS. When the ratio of high-/low-affinity values was plotted against efficacy, hyperbolic isotherms were obtained, consistent with a modified ternary complex model which assumes that receptors can adopt active conformations in the absence of agonist. In conclusion, modulation of [3H]-WAY100,635 binding by GTPgammaS differentiated agonist vs. inverse agonist properties of antipsychotics at 5-HT(1A) receptors. These may contribute to differing profiles of antipsychotic activity.

  17. Overview of Shipyard coast line with Piers G1, G2, G3, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Overview of Shipyard coast line with Piers G-1, G-2, G-3, G-4, and G-5 in view, view facing east-southeast - U.S. Naval Base, Pearl Harbor, Pier & Quay Walls, Entrance to Dry Dock No. 2 & Repair Wharfs, east & west sides of Dry Dock No. 2 & west side of Dry Dock No. 3, Pearl City, Honolulu County, HI

  18. 10 CFR 100.1 - Purpose.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... COMMISSION (CONTINUED) REACTOR SITE CRITERIA § 100.1 Purpose. (a) The purpose of this part is to establish approval requirements for proposed sites for stationary power and testing reactors subject to part 50 or part 52 of this chapter. (b) There exists a substantial base of knowledge regarding power reactor...

  19. Feasibility study of glass dosimeter postal dosimetry audit of high-energy radiotherapy photon beams.

    PubMed

    Mizuno, Hideyuki; Kanai, Tatsuaki; Kusano, Yohsuke; Ko, Susumu; Ono, Mari; Fukumura, Akifumi; Abe, Kyoko; Nishizawa, Kanae; Shimbo, Munefumi; Sakata, Suoh; Ishikura, Satoshi; Ikeda, Hiroshi

    2008-02-01

    The characteristics of a glass dosimeter were investigated for its potential use as a tool for postal dose audits. Reproducibility, energy dependence, field size and depth dependence were compared to those of a thermoluminescence dosimeter (TLD), which has been the major tool for postal dose audits worldwide. A glass dosimeter, GD-302M (Asahi Techno Glass Co.) and a TLD, TLD-100 chip (Harshaw Co.) were irradiated with gamma-rays from a (60)Co unit and X-rays from a medical linear accelerator (4, 6, 10 and 20 MV). The dosimetric characteristics of the glass dosimeter were almost equivalent to those of the TLD, in terms of utility for dosimetry under the reference condition, which is a 10 x 10 cm(2) field and 10 cm depth. Because of its reduced fading, compared to the TLD, and easy quality control with the ID number, the glass dosimeter proved to be a suitable tool for postal dose audits. Then, we conducted postal dose surveys of over 100 facilities and got good agreement, with a standard deviation of about 1.3%. Based on this study, postal dose audits throughout Japan will be carried out using a glass dosimeter.

  20. 46 CFR 56.01-1 - Scope (replaces 100.1).

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Scope (replaces 100.1). 56.01-1 Section 56.01-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... operation of the vessel. (c) Piping for industrial systems on mobile offshore drilling units need not fully...

  1. 46 CFR 56.01-1 - Scope (replaces 100.1).

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Scope (replaces 100.1). 56.01-1 Section 56.01-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... operation of the vessel. (c) Piping for industrial systems on mobile offshore drilling units need not fully...

  2. 46 CFR 56.01-1 - Scope (replaces 100.1).

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Scope (replaces 100.1). 56.01-1 Section 56.01-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... operation of the vessel. (c) Piping for industrial systems on mobile offshore drilling units need not fully...

  3. 46 CFR 56.01-1 - Scope (replaces 100.1).

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Scope (replaces 100.1). 56.01-1 Section 56.01-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... operation of the vessel. (c) Piping for industrial systems on mobile offshore drilling units need not fully...

  4. 46 CFR 56.01-1 - Scope (replaces 100.1).

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Scope (replaces 100.1). 56.01-1 Section 56.01-1 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND... operation of the vessel. (c) Piping for industrial systems on mobile offshore drilling units need not fully...

  5. SU-E-T-112: Experimental Characterization of a Novel Thermal Reservoir for Consistent and Accurate Annealing of High-Sensitivity TLDs.

    PubMed

    Donahue, W; Bongiorni, P; Hearn, R; Rodgers, J; Nath, R; Chen, Z

    2012-06-01

    To develop and characterize a novel thermal reservoir for consistent and accurate annealing of high-sensitivity thermoluminescence dosimeters (TLD-100H) for dosimetry of brachytherapy sources. The sensitivity of TLD-100H is about 18 times that of TLD-100 which has clear advantages in for interstitial brachytherapy sources. However, the TLD-100H requires a short high temperature annealing cycle (15 min.) and opening and closing the oven door causes significant temperature fluctuations leading to unreliable measurements. A new thermal reservoir made of aluminum alloy was developed to provide stable temperature environment in a standard hot air oven. The thermal reservoir consisted of a 20 cm × 20 cm × 8 cm Al block with a machine-milled chamber in the middle to house the aluminum TLD holding tray. The thermal reservoir was placed inside the oven until it reaches thermal equilibrium with oven chamber. The temperatures of the oven chamber, heat reservoir, and TLD holding tray were monitored by two independent thermo-couples which interfaced digitally to a control computer. A LabView interface was written for monitoring and recording the temperatures in TLD holding tray, the thermal reservoir, and oven chamber. The temperature profiles were measured as a function of oven-door open duration. The settings for oven chamber temperature and oven door open-close duration were optimized to achieve a stable temperature of 240 0C in the TLD holding tray. Complete temperature profiles of the TLD annealing tray over the entire annealing process were obtained. A LabView interface was written for monitoring and recording the temperatures in TLD holding The use of the thermal reservoir has significantly reduced the temperature fluctuations caused by the opening of oven door when inserting the TLD holding tray into the oven chamber. It has enabled consistent annealing of high-sensitivity TLDs. A comprehensive characterization of a custom-built novel thermal reservoir for annealing

  6. Serum IgG antibodies from healthy subjects up to 100 years old react to JC polyomavirus.

    PubMed

    Bononi, Ilaria; Mazzoni, Elisa; Pietrobon, Silvia; Manfrini, Marco; Torreggiani, Elena; Rossini, Marika; Lotito, Francesca; Guerra, Giovanni; Rizzo, Paola; Martini, Fernanda; Tognon, Mauro

    2018-08-01

    JC polyomavirus (JCPyV) was identified in 1971 in the brain tissue of a patient (J.C.) affected by the progressive multifocal leukoencephalopathy (PML). JCPyV encodes for the oncoproteins large T antigen (Tag) and small t-antigen (tag). These oncoproteins are responsible of the cell transformation and tumorigenesis in experimental animals. JCPyV is ubiquitous in human populations. After the primary infection, which is usually asymptomatic, JCPyV remains lifelong in the host in a latent phase. Its reactivation may occur in heathy subjects and immunocompromised patients. Upon reactivation, JCPyV could reach (i) the CNS inducing the PML, (ii) the kidney of transplant patients causing the organ rejection. Association between JCPyV, which is a small DNA tumor virus, and gliomas and colorectal carcinomas has been published. In the present investigation, we report on a new indirect ELISA with two specific synthetic peptides mimicking JCPyV VP1 immunogenic epitopes to detect specific serum IgG antibodies against JCPyV. Serum samples of healthy subjects (n = 355) ranging 2-100 years old, were analyzed by this new indirect ELISA. The linear peptides VP1 K and VP1 N resemble the natural JCPyV VP1 capsidic epitopes constituting a docking site for serum antibodies. Data from this innovative immunologic assay indicate that the overall prevalence of JCPyV-VP1 antibodies in healthy subjects is at 39%. The innovative indirect ELISA with JCPyV VP1 mimotopes seems to be a useful method to detect specific IgG antibodies against this virus, without cross-reactivity with the closely related SV40 and BKPyV polyomaviruses. © 2018 Wiley Periodicals, Inc.

  7. S100A11 promotes human pancreatic cancer PANC-1 cell proliferation and is involved in the PI3K/AKT signaling pathway.

    PubMed

    Xiao, Mingbing; Li, Tao; Ji, Yifei; Jiang, Feng; Ni, Wenkai; Zhu, Jing; Bao, Baijun; Lu, Cuihua; Ni, Runzhou

    2018-01-01

    S100A11, a member of S100 calcium-binding protein family, is associated with the numerous processes of tumorigenesis and metastasis. In the present study, the role of S100A11, and its possible underlying mechanisms in cell proliferation, apoptosis and cell cycle distribution in human pancreatic cancer were explored. Immunohistochemical analyses of S100A11 and phosphorylated (p)-AKT serine/threonine kinase (AKT) were performed in 30 resected specimens from patients with pancreatic cancer. PANC-1 cells were transfected with pcDNA3.1-S100A11 or treated with 50 µmol/l LY294002 for 48 h. Cell proliferation was determined using a cell counting kit-8 assay, whereas apoptosis and cell cycle distribution were determined by flow cytometry analysis. The mRNA and protein levels of S100A11, and AKT were determined using semi quantitative reverse transcription-polymerase chain reaction and western blot analyses, respectively. Pearson correlation analysis revealed that the expression levels of S100A11 and p-AKT were positively correlated (r, 0.802; P<0.05). Compared with the control group, S100A11 overexpression significantly promoted PANC-1 cell proliferation and reduced the percentage of early apoptotic cells. Flow cytometric analysis indicated that the proportion of PANC-1 cells in the S phase was significantly elevated and cell percentage in the G0/G1 phase declined in response to S100A11 overexpression (all P<0.05). S100A11 overexpression also significantly increased AKT mRNA and p-AKT protein expression levels (both P<0.05). The phosphoinositide 3-kinase (PI3K) inhibitor, LY294002, significantly inhibited PANC-1 cell proliferation, promoted apoptosis and caused G1/S phase arrest in PANC-1 cells (all P<0.05). These findings together suggest that S100A11 promotes the viability and proliferation of human pancreatic cancer PANC-1 cells through the upregulation of the PI3K/AKT signaling pathway. Thus, S100A11 may be considered as a novel drug target for targeted therapy of

  8. Coexistence of ACE (I/D) and PAI-1 (4G/5G) gene variants in recurrent miscarriage in Polish population.

    PubMed

    Kurzawińska, Grażyna; Barlik, Magdalena; Drews, Krzysztof; Różycka, Agata; Seremak-Mrozikiewicz, Agnieszka; Ożarowski, Marcin; Klejewski, Andrzej; Czerny, Bogusław; Wolski, Hubert

    2016-01-01

    Recurrent miscarriage (RM) is one of the most common obstetric complications. Numerous studies have suggested that genetic variants leading to an impaired balance between coagulation and fibrinolysis may contribute to elevated risk of pregnancy loss. The aim of the study was to investigate a possible association between angiotensin-converting enzyme (ACE, rs1799752) I/D and plasminogen activator inhibitor type 1 (PAI-1, rs1799768) 4G/5G polymorphisms with RM among Polish women. DNA was extracted from peripheral blood samples of 152 women with a history of ≥ 2 consecutive pregnancy losses before 22 weeks of gestation, and 180 healthy controls with at least 1 live birth at term and no history of pregnancy loss. Polymerase chain reaction (PCR) and restriction fragment length polymorphism (RFLP) were used to identify the polymorphisms. No statistically significant differences were found in genotype and allele frequencies of the studied polymorphisms. The most relevant difference between the study group and controls was found for the ID genotype distribution of the ACE gene (52.6 vs. 46.7%, OR = 1.27, p = 0.28). The analysis of genotype coexistence revealed a higher incidence of the combination of the ACE II and the PAI-1 4G/4G genotypes in the control group (10.0 vs.5.9% in control group; p = 0.17). The obtained results suggest no apparent association between the ACE I/D, PAI-1 4G/5G polymorphisms and increased RM susceptibility in the analyzed Polish population.

  9. Detection of G1 genotype of human cystic echinococcosis in Egypt.

    PubMed

    Abd El Baki, Mohammad H; El Missiry, Adel M G; Abd El Aaty, Heba E M; Mohamad, Anhar A; Aminou, Heba A R

    2009-12-01

    The first trial to detect G1 genotype in Egyptian human isolates of hydatid cysts (HC) and serum samples to approach diagnosis of cystic echinococcosis (CE) using human sera by PCR. Using strain specific primers, 27/36 confirmed CE patients (75%) showed G1 specific band in their sera at 254 bp. Specificity was 100% without detecting bands for either other parasitosis, or mass occupying lesions. Using PCR, G1 genotype was detected in 83.3% of HC samples, without significant difference between types of human isolates (pulmonary, hepatic, or multi-organ). G1 genotype detection in human sera was in 75% of CE patients compared to 83.3% in HC samples of the same group of patients proved satisfactory, simple and safer than HCF sampling. IHAT gave sensitivity of 58.3% compared to histopathological examination of surgically removed cysts or examination of hydatid cyst fluid (HCF) for protoscolices (gold standards). The specificity was 70% with false positive reactions with other parasitic infections and mass occupying lesions. PCR detection of G1 genotype in Egyptian animal hydatid cysts showed 90% in camel isolates and 80% in sheep isolates, but pig isolates were negative. The presence of this genotype in a high percentage in camel isolates incriminated sheep strain as the source of CE camel infection. The results may give an explanation to the contradicting results of other studies that did not relay upon molecular aspects.

  10. The use of TLD-700H dosemeters in the assessment of external doses at the former Semipalatinsk nuclear test site.

    PubMed

    Hill, P; Dederichs, H; Pillath, J; Schlecht, W; Hille, R; Artemev, O; Ptitskaya, L; Akhmetov, M

    2002-01-01

    The joint projects performed since 1995 by the Jülich Research Centre in co-operation with the Kazakh National Nuclear Centre in the area of the former nuclear test site near Semipalatinsk, in eastern Kazakhstan, have assessed the current dose rate of the population at and around the test site, as well as determining retrospectively the dose rate of persons affected by the atmospheric tests. Measurements of the population by personal dosemeters depend on reliably wearing these dosemeters over prolonged periods of time, and of a sufficient dosemeter return. In the past, such measurements have been particularly successful whenever short wearing times were possible. This requires high sensitivity of the dosemeters. The suitability of the highly sensitive TLD material of the BICRON TLD 700H type for such personal dosimetry measurements was investigated. It was tested in practical field application at the Semipalatinsk nuclear test site in September 2000. Initial results are available from individual doses received by a group of geologists and a group of herdsmen at the test site. For the first time, the individual dose was measured directly in these population groups. Detection limits below 1 microSv permit informative measurements for wearing times of less than two weeks. Most individual doses did not arise significantly out of local fluctuations of natural background. A conservative assessment from the aspect of practical health physics yielded a mean personal dose of 0.55 microSv per day for the herdsmen, whereas the geologists received a mean personal dose of 0.45 microSv per day. For an annual exposure period of typically, about three months, the radiation dose received by the persons investigated, in addition to the natural radiation exposure, is thus well below the international limit value of 1 mSv x a(-1) for the population dose.

  11. The Thermoluminescent Response of Several Phosphors to Monoenergetic Photon Beams with Energies from 275 TO 2,550 EV.

    NASA Astrophysics Data System (ADS)

    Carrillo Beltran, Ricardo Enrique

    The thermoluminescent (TL) response of LiF:Mg,Ti (TLD-100) and CaF_2:Dy (TLD-200) to monoenergetic photon beams was measured for photons with energies between 275 and 2,550 eV produced by the Aladdin synchrotron accelerator of the UW-Madison. The change of the TL response, as measured by the 130-215 ^circC integrated light output for TLD-100, the 170-250^circC TL interval for TLD-200 and the height of the main dosimetric peak at 200^circC for both phosphors as a function of total energy deposited up to saturation is described. Glow curves were determined for TLDs annealed in helium and irradiated at various photon energies. Glow curves showing the adverse effect of air annealing upon the TL sensitivity of these phosphors are presented as well. Supralinearity factors for each TLD type were calculated using the integrated TL and the main peak height and are listed for the photon energy beams employed. High surface doses were achieved with these irradiations because of the short mean free path of the photons and the even shorter range of the freed electrons, both plotted. Despite the shallower penetration of the photons in TLD-200 as compared to TLD-100, the former phosphor was found to be more suitable for routine use as a synchrotron radiation monitor because its TL properties change very little with photon energy as shown by its constant glow curve obtained. TLD-100 glow curve, either from a chip or a crystal, changed according to the photon energy employed; this adverse effect was more pronounced with the chips.

  12. 4G/5G polymorphism modulates PAI-1 circulating levels in obese women.

    PubMed

    Fernandes, Karla S; Sandrim, Valéria C

    2012-05-01

    The increase in plasminogen activator inhibitor type 1 (PAI-1) has been described as a risk factor to thrombosis-related diseases. In addition, it has been demonstrated that the variant 4G of polymorphism 4G/5G located in promoter region of PAI-1 gene is associated with higher PAI-1 levels. We investigate the role of this polymorphism on circulating PAI-1 concentration in a population of 57 obese women (23%, 4G/4G; 49%, 4G/5G and 28%, 5G/5G genotypes). Our results demonstrate a genotype-specific modulation on PAI-1 levels in obese women, thus 5G/5G genotype presented significantly lower levels of plasma PAI-1 when compared to 4G/4G group (46 ± 19 ng/mL vs. 63 ± 13 ng/mL, respectively). Our findings indicate that obese carriers of 4G/4G genotype may have increased risk to develop thrombotic diseases.

  13. 26 CFR 1.167(g)-1 - Basis for depreciation.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 2 2012-04-01 2012-04-01 false Basis for depreciation. 1.167(g)-1 Section 1.167(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.167(g)-1 Basis...

  14. 26 CFR 1.167(g)-1 - Basis for depreciation.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 2 2011-04-01 2011-04-01 false Basis for depreciation. 1.167(g)-1 Section 1.167(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.167(g)-1 Basis...

  15. 26 CFR 1.167(g)-1 - Basis for depreciation.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 2 2014-04-01 2014-04-01 false Basis for depreciation. 1.167(g)-1 Section 1.167(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.167(g)-1 Basis...

  16. 26 CFR 1.167(g)-1 - Basis for depreciation.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Basis for depreciation. 1.167(g)-1 Section 1.167(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.167(g)-1 Basis...

  17. 26 CFR 1.167(g)-1 - Basis for depreciation.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 2 2013-04-01 2013-04-01 false Basis for depreciation. 1.167(g)-1 Section 1.167(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Itemized Deductions for Individuals and Corporations § 1.167(g)-1 Basis...

  18. Nuclease digestion and mass spectrometric characterization of oligodeoxyribonucleotides containing 1,2-GpG, 1,2-ApG, and 1,3-GpXpG cisplatin intrastrand cross-links.

    PubMed

    Williams, Renee T; Nalbandian, Jenifer N; Tu, Audrey; Wang, Yinsheng

    2013-05-01

    The primary mode of action for cis-diamminedichloroplatinum (II), referred to as cisplatin, toward the treatment of solid malignancies is through formation of cross-links with DNA at purine sites, especially guanines. We prepared oligodeoxyribonucleotides (ODNs) containing a 1,2-GpG, 1,2-ApG, or 1,3-GpXpG cisplatin intrastrand cross-link and the corresponding ODNs modified with (15)N2-labeled cisplatin, and characterized these ODNs with electrospray ionization mass spectrometry (ESI-MS) and tandem MS (MS/MS). We also employed LC-MS/MS to characterize the digestion products of these ODNs after treatment with a cocktail of 4 enzymes (nuclease P1, phosphodiesterases I and II, and alkaline phosphatase). 1,2-GpG was released from the ODNs as a dinucleoside monophosphate or a dinucleotide. Analyses of the digestion products of ODNs containing a 1,2-GpG cross-link on the 5' or 3' terminus revealed that the dinucleotide carries a terminal 5' phosphate. On the other hand, digestion of the 1,3-GpXpG intrastrand cross-link yielded 3 dinucleoside products with 0, 1, or 2 phosphate groups. The availability of the ODNs carrying the stable isotope-labeled lesions, MS/MS analyses of the cisplatin-modified ODNs, and the characterization of the enzymatic digestion products of these ODNs set the stage for the future LC-MS/MS quantification of the 1,2-GpG, 1,2-ApG, and 1,3-GpXpG lesions in cellular DNA. Copyright © 2012 Elsevier B.V. All rights reserved.

  19. Nuclease Digestion and Mass Spectrometric Characterization of Oligodeoxyribonucleotides Containing 1,2-GpG, 1,2-ApG, and 1,3-GpXpG Cisplatin Intrastrand Cross-links

    PubMed Central

    Williams, Renee T.; Nalbandian, Jenifer; Tu, Audrey; Wang, Yinsheng

    2013-01-01

    Background The primary mode of action for cis-diamminedichloroplatinum (II), referred to as cisplatin, towards the treatment of solid malignancies is through formation of cross-links with DNA at purine sites, especially guanines. Methods We prepared oligodeoxyribonucleotides (ODNs) containing a 1,2-GpG, 1,2-ApG, or 1,3-GpXpG cisplatin intrastrand cross-link and the corresponding ODNs modified with 15N2-labeled cisplatin, and characterized these ODNs with electrospray ionization mass spectrometry (ESI-MS) and tandem MS (MS/MS). We also employed LC-MS/MS to characterize the digestion products of these ODNs after treatment with a cocktail of 4 enzymes (nuclease P1, phosphodiesterases I and II, and alkaline phosphatase). Results 1,2-GpG was released from the ODNs as a dinucleoside monophosphate or a dinucleotide. Analyses of the digestion products of ODNs containing a 1,2-GpG cross-link on the 5′ or 3′ terminus revealed that the dinucleotide carries a terminal 5′ phosphate. On the other hand, digestion of the 1,3-GpXpG intrastrand cross-link yielded 3 dinucleoside products with 0, 1, or 2 phosphate groups. Results The availability of the ODNs carrying the stable isotope-labeled lesions, MS/MS analyses of the cisplatin-modified ODNs, and the characterization of the enzymatic digestion products of these ODNs set the stage for the future LC-MS/MS quantification of the 1,2-GpG, 1,2-ApG, and 1,3-GpXpG lesions in cellular DNA. PMID:23266768

  20. 26 CFR 1.56(g)-1 - Adjusted current earnings.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 1 2014-04-01 2013-04-01 true Adjusted current earnings. 1.56(g)-1 Section 1.56(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Regulations Applicable to Taxable Years Beginning in 1969 and Ending in 1970 § 1.56(g)-1 Adjusted current...

  1. 26 CFR 1.56(g)-1 - Adjusted current earnings.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 1 2012-04-01 2012-04-01 false Adjusted current earnings. 1.56(g)-1 Section 1.56(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Regulations Applicable to Taxable Years Beginning in 1969 and Ending in 1970 § 1.56(g)-1 Adjusted current...

  2. 26 CFR 1.56(g)-1 - Adjusted current earnings.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 1 2011-04-01 2009-04-01 true Adjusted current earnings. 1.56(g)-1 Section 1.56(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Regulations Applicable to Taxable Years Beginning in 1969 and Ending in 1970 § 1.56(g)-1 Adjusted current...

  3. 26 CFR 1.56(g)-1 - Adjusted current earnings.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 1 2013-04-01 2013-04-01 false Adjusted current earnings. 1.56(g)-1 Section 1.56(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY INCOME TAX INCOME TAXES Regulations Applicable to Taxable Years Beginning in 1969 and Ending in 1970 § 1.56(g)-1 Adjusted current...

  4. The plasminogen activator inhibitor-1 (PAI-1) gene -844 A/G and -675 4G/5G promoter polymorphism significantly influences plasma PAI-1 levels in women with polycystic ovary syndrome.

    PubMed

    Lin, Sun; Huiya, Zhang; Bo, Liu; Wei, Wei; Yongmei, Guan

    2009-12-01

    Mutations in the plasminogen activator inhibitor-1 (PAI-1) gene, along with increased PAI-1 levels, have been implicated in the pathogenesis of polycystic ovarian syndrome (PCOS). We investigated a possible influence of the promoter polymorphism (-844 A/G and -675 4G/5G) in the PAI-1 gene on plasma PAI-1 levels in 126 PCOS patients and 97 healthy controls. Levels of total testosterone, luteinizing hormone (LH), follicle stimulating hormone (FSH), fasting plasma glucose (FPG), fasting insulin, and PAI-1 were measured, and body mass index (BMI), waist-to-hip ratio (WHR), LH/FSH ratio, and homeostasis model assessment for insulin resistance (HOMA-IR) were calculated. PAI-1 -675 4G/5G and -844 A/G gene polymorphisms were also performed. Total testosterone, fasting insulin, and PAI-1 levels; BMI, LH/FSH, and HOMA-IR were significantly higher in PCOS patients than controls (P < 0.05). The odds ratio of 4G/4G genotype, 4G allele, and the combination genotype of 4G/4G and -844 A/A were 2.49 (95% confidence interval (CI), 1.4-4.44), 2.1 (95% CI, 1.43-3.08), and 2.9 (95% CI, 1.41-5.98), respectively, (P < 0.001). In the PCOS group, the PAI-1 level of the A/A was significantly higher than that of the A/G or G/G genotype, similarly was 4G/4G genotype compared with 4G/5G or 5G/5G genotype. The plasma PAI-1 levels of the combination of the PAI-1 -844 A/A and -675 4G/4G or 4G/5G genotypes, or the coadunation of 4G/4G and -844 non-G/G (A/A + A/G) genotypes were significantly high in PCOS women compared with controls. A trend to a positive interaction between PAI-1 -675 4G/5G and -844 A/G gene polymorphism may elevate plasma PAI-1 levels and hypofibrinolysis, which is probably an important hereditary risk factor in PCOS.

  5. 26 CFR 1.514(g)-1 - Business lease indebtedness.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 7 2014-04-01 2013-04-01 true Business lease indebtedness. 1.514(g)-1 Section 1.514(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt Organizations § 1.514(g)-1...

  6. 26 CFR 1.514(g)-1 - Business lease indebtedness.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 7 2011-04-01 2009-04-01 true Business lease indebtedness. 1.514(g)-1 Section 1.514(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt Organizations § 1.514(g)-1...

  7. 26 CFR 1.514(g)-1 - Business lease indebtedness.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 7 2010-04-01 2010-04-01 true Business lease indebtedness. 1.514(g)-1 Section 1.514(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt Organizations § 1.514(g)-1...

  8. Cytokinetically quiescent (G0/G1) human multiple myeloma cells are susceptible to simultaneous inhibition of Chk1 and MEK1/2

    PubMed Central

    Pei, Xin-Yan; Dai, Yun; Youssefian, Leena E.; Chen, Shuang; Bodie, Wesley W.; Takabatake, Yukie; Felthousen, Jessica; Almenara, Jorge A.; Kramer, Lora B.; Dent, Paul

    2011-01-01

    Effects of Chk1 and MEK1/2 inhibition were investigated in cytokinetically quiescent multiple myeloma (MM) and primary CD138+ cells. Coexposure to the Chk1 and MEK1/2 inhibitors AZD7762 and selumetinib (AZD6244) robustly induced apoptosis in various MM cells and CD138+ primary samples, but spared normal CD138− and CD34+ cells. Furthermore, Chk1/MEK1/2 inhibitor treatment of asynchronized cells induced G0/G1 arrest and increased apoptosis in all cell-cycle phases, including G0/G1. To determine whether this regimen is active against quiescent G0/G1 MM cells, cells were cultured in low-serum medium to enrich the G0/G1 population. G0/G1–enriched cells exhibited diminished sensitivity to conventional agents (eg, Taxol and VP-16) but significantly increased susceptibility to Chk1 ± MEK1/2 inhibitors or Chk1 shRNA knock-down. These events were associated with increased γH2A.X expression/foci formation and Bim up-regulation, whereas Bim shRNA knock-down markedly attenuated lethality. Immunofluorescent analysis of G0/G1–enriched or primary MM cells demonstrated colocalization of activated caspase-3 and the quiescent (G0) marker statin, a nuclear envelope protein. Finally, Chk1/MEK1/2 inhibition increased cell death in the Hoechst-positive (Hst+), low pyronin Y (PY)–staining (2N Hst+/PY−) G0 population and in sorted small side-population (SSP) MM cells. These findings provide evidence that cytokinetically quiescent MM cells are highly susceptible to simultaneous Chk1 and MEK1/2 inhibition. PMID:21911831

  9. Cytokinetically quiescent (G0/G1) human multiple myeloma cells are susceptible to simultaneous inhibition of Chk1 and MEK1/2.

    PubMed

    Pei, Xin-Yan; Dai, Yun; Youssefian, Leena E; Chen, Shuang; Bodie, Wesley W; Takabatake, Yukie; Felthousen, Jessica; Almenara, Jorge A; Kramer, Lora B; Dent, Paul; Grant, Steven

    2011-11-10

    Effects of Chk1 and MEK1/2 inhibition were investigated in cytokinetically quiescent multiple myeloma (MM) and primary CD138(+) cells. Coexposure to the Chk1 and MEK1/2 inhibitors AZD7762 and selumetinib (AZD6244) robustly induced apoptosis in various MM cells and CD138(+) primary samples, but spared normal CD138(-) and CD34(+) cells. Furthermore, Chk1/MEK1/2 inhibitor treatment of asynchronized cells induced G(0)/G(1) arrest and increased apoptosis in all cell-cycle phases, including G(0)/G(1). To determine whether this regimen is active against quiescent G(0)/G(1) MM cells, cells were cultured in low-serum medium to enrich the G(0)/G(1) population. G(0)/G(1)-enriched cells exhibited diminished sensitivity to conventional agents (eg, Taxol and VP-16) but significantly increased susceptibility to Chk1 ± MEK1/2 inhibitors or Chk1 shRNA knock-down. These events were associated with increased γH2A.X expression/foci formation and Bim up-regulation, whereas Bim shRNA knock-down markedly attenuated lethality. Immunofluorescent analysis of G(0)/G(1)-enriched or primary MM cells demonstrated colocalization of activated caspase-3 and the quiescent (G(0)) marker statin, a nuclear envelope protein. Finally, Chk1/MEK1/2 inhibition increased cell death in the Hoechst-positive (Hst(+)), low pyronin Y (PY)-staining (2N Hst(+)/PY(-)) G(0) population and in sorted small side-population (SSP) MM cells. These findings provide evidence that cytokinetically quiescent MM cells are highly susceptible to simultaneous Chk1 and MEK1/2 inhibition.

  10. Plasminogen Activator Inhibitor-1 (PAI-1) gene 4G/5G alleles frequency distribution in the Lebanese population.

    PubMed

    Shammaa, Dina M R; Sabbagh, Amira S; Taher, Ali T; Zaatari, Ghazi S; Mahfouz, Rami A R

    2008-09-01

    Plasminogen activator inhibitor-1 (PAI-1) is an inhibitor of fibrinolysis. Increased plasma PAI-1 levels play an essential role in the pathogenesis of cardiovascular risk and other diseases associated with thrombosis. The 4G/5G polymorphism of the PAI-1 promoter region has been extensively studied in different populations. We studied 160 healthy unrelated Lebanese individuals using a reverse hybridization PCR assay to detect the 5G/5G, 4G/5G and, 4G/4G genotypes of the PAI-1 gene and the frequencies of the 4G and 5G alleles. We found that 4G/5G genotype was the most prevalent (45.6%) followed by 5G/5G (36.9%) and 4G/4G (17.5%). The frequencies of the 4G and 5G alleles were calculated to be 0.403 and 0.597, respectively. Compared to other ethnic communities, the Lebanese population was found to harbour a relatively high prevalence of the rare 4G allele. This, in turn, may predispose this population to develop cardiovascular diseases and other thrombotic clinical conditions. This study aids to enhance our understanding of the genetic features of the Lebanese population.

  11. Inhibition of Expression of the S100A8 Gene Encoding the S100 Calcium-Binding Protein A8 Promotes Apoptosis by Suppressing the Phosphorylation of Protein Kinase B (Akt) in Endometrial Carcinoma and HEC-1A Cells.

    PubMed

    Liu, Chang; Xing, Guangyang; Wu, Cailiang; Zhu, Jun; Wei, Min; Liu, Dajiang; Ge, Yan; Chen, Yao; Lei, Ting; Yang, Yongxiu

    2018-03-29

    BACKGROUND The aim of this study was to investigate the expression and silencing of the S100A8 gene, which encodes the S100 calcium-binding protein A8 (S100A8), and apoptosis and phosphorylation of protein kinase B (Akt) in tissue samples of endometrial carcinoma and HEC-1A endometrial adenocarcinoma cells in vitro. MATERIAL AND METHODS Immunohistochemistry (IHC) was used to detect expression of the S100A8 protein in 74 tissue samples of endometrial cancer and 22 normal endometrial tissue samples. A stable S100A8 gene knockdown cell line was constructed using lentiviral packing short hairpin RNA (shRNA) transfected into HEC-1A cells. S100A8 mRNA and S100A8 protein levels were detected by quantitative reverse transcription-polymerase chain reaction (qRT-PCR) and Western blotting. The effects of expression of the S100A8 gene by endometrial cancer cells was investigated by the MTT assay, cell cycle and apoptotic assays, qRT-PCR, and Western blotting. RESULTS IHC showed high levels of expression of S100A8 protein in endometrial carcinoma tissues, and HEC-1A adenocarcinoma cells (in G1 and G2). Increased expression of S100A8 protein was found endometrial cancer tissues compared with normal endometrial tissues (79.7% vs. 4.5%). S100A8 gene knockdown reduced cell proliferation in the HEC-1A cells compared with control cells, induced cell apoptosis, inhibited the phosphorylation of protein kinase B (Akt), and induced the expression of pro-apoptotic genes, including the cytochrome C gene, CYCS, BAD, BAX, FOXO1, FOXO3, CASP9, and CASP3. CONCLUSIONS In endometrial carcinoma cells, down-regulation of the S100A8 gene induced cell apoptosis via inhibition of the phosphorylated or active form of protein kinase B (Akt).

  12. HMB-45, S-100, NK1/C3, and MART-1 in metastatic melanoma.

    PubMed

    Zubovits, Judit; Buzney, Elizabeth; Yu, Lawrence; Duncan, Lyn M

    2004-02-01

    The diagnosis of melanoma metastatic to lymph node remains a difficult problem given its histological diversity. We examined the staining patterns of S-100, NK1/C3, HMB-45, and MART-1 (DC10) in melanoma metastases to lymph nodes. Immunohistochemical stains were performed on tissue sections of 126 formalin-fixed lymph nodes from 126 patients with an established diagnosis of metastatic melanoma. A total of 98% of cases (123 of 126) stained positive for S-100, 93% (117 of 125) stained positive for NK1/C3, 82% (103 of 126) stained positive for MART-1, and 76% (95 of 125) stained positive for HMB-45. The distribution and intensity of staining varied among these markers. A diffuse staining pattern, defined as >50% of tumor cells stained, was observed in 83% of MART-1-positive cases but in only 56% of S-100-positive cases, 48% of NK1/C3-positive cases, and 34% of HMB-45-positive cases. A maximally intense signal was almost always observed for MART-1 (83% of positive cases) but was rarely observed for NK1/C3 (20%). S-100 and HMB-45 showed maximally intense staining in 50% and 54% of cases, respectively. S-100 and NK1/C3 stained both histiocytes and melanocytes, whereas MART-1 and HMB-45 stained only melanocytes. Seventy-eight cases (63%) stained positive for all 4 markers, 17 cases (14%) stained for all markers except HMB-45, 13 cases (10%) stained for all markers except MART-1, 6 cases (5%) stained only with S-100 and NK1/C3, 4 cases (3%) stained only with S-100 and HMB-45, and 2 cases stained for all markers except S-100. One case each stained for the following: only S-100, only S-100 and HMB-45, and all markers except NK1/C3. One case exhibited absence of staining for any of these markers. We demonstrate that lymph node metastases of melanoma are heterogeneous with regard to tumor marker expression. S-100 and NK1/C3 were the most sensitive stains for detecting metastatic melanoma; however, they both also stain other nontumor cells in lymph nodes. MART-1 did not stain

  13. The Cold Dust Content of the Oxygen-rich Supernova Remnant G292.0+1.8

    NASA Astrophysics Data System (ADS)

    Ghavamian, Parviz; Williams, Brian J.

    2016-11-01

    We present far-infrared images of the Galactic oxygen-rich supernova remnant (SNR) G292.0+1.8, acquired with the PACS and SPIRE instruments of the Herschel Space Observatory. We find that the SNR shell is detected in the PACS blue (100 μm) band, but not in the red (160 μm) band, broadly consistent with results from AKARI observations. There is no discernible emission from G292.0+1.8 in SPIRE imagery at 250, 350 and 500 μm. Comparing the 100 μm emission to that observed with Spitzer at 24 and 70 μm, we find a very similar appearance for G292.0+1.8 at all three wavelengths. The infrared emission is dominated by dust from non-radiative circumstellar shocks. In addition, the radiatively shocked O-rich clump known as the “Spur” on the eastern side of G292.0+1.8 is clearly detected in the PACS blue images, with marginal detection in the red. Fitting the existing 14-40 μm IRS spectra of the Spur together with photometric measurements from 70 μm MIPS and 100 μm PACS photometry, we place an upper limit of ≲ 0.04 M ⊙ of ejecta dust mass in the Spur, under the most conservative assumption that the ejecta dust has a temperature of 15 K. Modeling the dust continuum in the IRS spectra at four positions around the rim, we estimate post-shock densities ranging from {n}p=3.5 cm-3 to 11 cm-3. The integrated spectrum of the entire SNR, dominated by swept-up circumstellar dust, can be fitted with a two-component dust model with a silicate component at 62 K and graphite component at 40 K for a total dust mass of 0.023 M ⊙.

  14. SU-E-T-87: Comparison Study of Dose Reconstruction From Cylindrical Diode Array Measurements, with TLD Measurements and Treatment Planning System Calculations in Anthropomorphic Head and Neck and Lung Phantoms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benhabib, S; Cardan, R; Huang, M

    Purpose: To assess dose calculated by the 3DVH software (Sun Nuclear Systems, Melbourne, FL) against TLD measurements and treatment planning system calculations in anthropomorphic phantoms. Methods: The IROC Houston (RPC) head and neck (HN) and lung phantoms were scanned and plans were generated using Eclipse (Varian Medical Systems, Milpitas, CA) following IROC Houston procedures. For the H and N phantom, 6 MV VMAT and 9-field dynamic MLC (DMLC) plans were created. For the lung phantom 6 MV VMAT and 15 MV 9-field dynamic MLC (DMLC) plans were created. The plans were delivered to the phantoms and to an ArcCHECK (Sunmore » Nuclear Systems, Melbourne, FL). The head and neck phantom contained 8 TLDs located at PTV1 (4), PTV2 (2), and OAR Cord (2). The lung phantom contained 4 TLDs, 2 in the PTV, 1 in the cord, and 1 in the heart. Daily outputs were recorded before each measurement for correction. 3DVH dose reconstruction software was used to project the calculated dose to patient anatomy. Results: For the HN phantom, the maximum difference between 3DVH and TLDs was -3.4% and between 3DVH and Eclipse was 1.2%. For the lung plan the maximum difference between 3DVH and TLDs was 4.3%, except for the spinal cord for which 3DVH overestimated the TLD dose by 12%. The maximum difference between 3DVH and Eclipse was 0.3%. 3DVH agreed well with Eclipse because the dose reconstruction algorithm uses the diode measurements to perturb the dose calculated by the treatment planning system; therefore, if there is a problem in the modeling or heterogeneity correction, it will be carried through to 3DVH. Conclusion: 3DVH agreed well with Eclipse and TLD measurements. Comparison of 3DVH with film measurements is ongoing. Work supported by PHS grant CA10953 and CA81647 (NCI, DHHS)« less

  15. Tmem100 is a regulator of TRPA1-TRPV1 complex and contributes to persistent pain

    PubMed Central

    Weng, Hao-Jui; Patel, Kush N.; Jeske, Nathaniel A.; Bierbower, Sonya M.; Zou, Wangyuan; Tiwari, Vinod; Zheng, Qin; Tang, Zongxiang; Mo, Gary C.H.; Wang, Yan; Geng, Yixun; Zhang, Jin; Guan, Yun; Akopian, Armen; Dong, Xinzhong

    2014-01-01

    SUMMARY TRPA1 and TRPV1 are crucial pain mediators, but how their interaction contributes to persistent pain is unknown. Here, we identify Tmem100 as a potentiating modulator of TRPA1-V1 complexes. Tmem100 is co-expressed and forms a complex with TRPA1 and TRPV1 in DRG neurons. Tmem100-deficient mice show a reduction in inflammatory mechanical hyperalgesia and TRPA1- but not TRPV1-mediated pain. Single-channel recording in a heterologous system reveals that Tmem100 selectively potentiates TRPA1 activity in a TRPV1-dependent manner. Mechanistically, Tmem100 weakens the association of TRPA1 and TRPV1, thereby releasing the inhibition of TRPA1 by TRPV1. A Tmem100 mutant, Tmem100-3Q, exerts the opposite effect, i.e., it enhances the association of TRPA1 and TRPV1 and strongly inhibits TRPA1. Strikingly, a cell-permeable peptide (CPP) containing the C-terminal sequence of Tmem100-3Q mimics its effect and inhibits persistent pain. Our study unveils a context-dependent modulation of the TRPA1-V1 complex, and Tmem100-3Q CPP is a promising pain therapy. PMID:25640077

  16. Maleimidobenzoyl-G-actin: Structural properties and interaction with skeletal myosin subfragment-1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bettache, N.; Bertrand, R.; Kassab, R.

    1990-09-25

    The authors have investigated various structural and interaction properties of maleimidobenzoyl-G-actin (MBS-actin), a new, internally cross-linked G-actin derivative that does not exhibit, at moderate protein concentration, the salt-and myosin subfragment 1 (S-1)--induced polymerizations of G-actin and reacts reversibly and covalently in solution with S-1 at or near the F-actin binding region of the heavy chain. The far-ultraviolet CD spectrum and {alpha}-helix content of the MBS-actin were identical with those displayed by native G-actin. {sup 45}Ca{sup 2+} measurements showed the same content of tightly bound Ca{sup 2+} in MBS-actin as in G-actin and the EDTA treatment of the modified protein promotedmore » the same red shift of the intrinsic fluorescence spectrum as observed with native G-actin. Incubation of concentrated MBS-actin solutions with 100 mM KCl+5 mM MgCl{sub 2} led to the polymerization of the actin derivative when the critical monomer concentration reached 1.6mg/mL, at 25{degree}C, pH 8.0. The MBS-F-actin formed activated the Mg{sup 2+}-ATPase of S-1 to the same extent as native F-actin. The MBS-G-actin exhibited a DNase I inhibitor activity very close to that found with native G-actin and was to be at all affected by its specific covalent conjugation to S-1. This finding led them to isolate, for the first time, by gel filtration, a ternary complex comprising DNase I tightly bound to MBS-actin cross-linked to the S-1 heavy chain, demonstrating that S-1 and DNase I bind at distinct sites on G-actin. Collectively, the data illustrate further the nativeness of the MBS-G-actin and its potential use in solution studies of the actin-myosin head interactions.« less

  17. ApoB-100 secretion by HepG2 cells is regulated by the rate of triglyceride biosynthesis but not by intracellular lipid pools.

    PubMed

    Benoist, F; Grand-Perret, T

    1996-10-01

    Triglycerides (TGs), cholesteryl esters (CEs), cholesterol, and phosphatidylcholine have been independently proposed as playing regulatory roles in apoB-100 secretion; the results depended on the cellular model used. In this study, we reinvestigate the role of lipids in apoB-100 production in HepG2 cells and in particular, we clarify the respective roles of intracellular mass and the biosynthesis of lipids in the regulation of apoB-100 production. In a first set of experiments, the pool size of cholesterol, CEs, and TGs was modulated by a 3-day treatment with either lipid precursors or inhibitors of enzymes involved in lipid synthesis. We used simvastatin (a hydroxymethylglutaryl coenzyme A reductase inhibitor), 58-035 (an acyl coenzyme A cholesterol acyltransferase inhibitor), 5-tetradecyloxy-2-furancarboxylic acid (TOFA, an inhibitor of fatty acid synthesis), and oleic acid. The secretion rate of apoB-100 was not affected by the large modulation of lipid mass induced by these various pre-treatments. In a second set of experiments, the same lipid modulators were added during a 4-hour labeling period. Simvastatin and 58-035 inhibited cholesterol and CE synthesis without affecting apoB-100 secretion. By contrast, treatment of HepG2 cells with TOFA resulted in the inhibition of TG synthesis and apoB-100 secretion. This effect was highly specific for apoB-100 and was reversed by adding oleic acid, which stimulated both TG synthesis and apoB-100 secretion. Moreover, a combination of oleic acid and 58-035 inhibited CE biosynthesis and increased both TG synthesis and apoB-100 secretion. These results show that in HepG2 cells TG biosynthesis regulates apoB-100 secretion, whereas the rate of cholesterol or CE biosynthesis has no effect.

  18. Demonstration of IgG Subclass (IgG1 and IgG3) in Immuno-Related Hemocytopenia.

    PubMed

    Shao, Yuanyuan; Qi, Xiao; Fu, Rong; Liu, Hui; Wang, Yihao; Ding, Shaoxue; Wang, Huaquan; Li, Lijuan; Shao, Zonghong

    2018-06-01

    Immuno-related hemocytopenia (IRH) is defined as idiopathic cytopenia of undetermined significance (ICUS) patients with autoantibodies. In our previous studies, we found that IgG1 levels were increased in IRH patients and might cause the destruction of hematopoietic cells. In this study, we analyzed IgG subclasses in 30 IRH patients (male:female = 13:17, median age 32 years, range 18 - 56), 15 IRH remission patients (IRH-R) (male:female = 6:9, median age 34, range 20 - 52) and 20 normal controls (male:female = 8:12, median age 27, range 24 - 36) by Cytometric Bead Array, Flow Cytometry and Immunohistochemical staining. Levels of IgG1/IgG3 in the bone marrow supernatant of IRH patents, as well as the proportion of CD5+ B lymphocytes and Th2 cells (CD3+CD8-IL-4+) were higher than those of IRH-R patients and normal controls, and IgG1 levels had a positive correlation with the proportion of Th2 cells. In IRH patients, IgG1 and IgG3 were positive on nucleated erythrocytes and granulocytes, which were negative in IRH-R patients and healthy controls and had inverse correlations with hematopoietic function. Using immunohistochemical staining, IgG1 were also detected on bone marrow biopsies of IRH patients. The results indicated that IgG1 and IgG3 autoantibodies in IRH patients might play a key role in the IRH pathogenesis and in the abnormal immune function of IRH patients.

  19. Chlorogenic acid isomer contents in 100 plants commercialized in Brazil.

    PubMed

    Meinhart, Adriana Dillenburg; Damin, Fernanda Mateus; Caldeirão, Lucas; da Silveira, Tayse Ferreira Ferreira; Filho, José Teixeira; Godoy, Helena Teixeira

    2017-09-01

    This study analysed 100 plants employed in Brazil as ingredients to infusions for their caffeic acid, 3-caffeoylquinic acid (3-CQA), 4-caffeoylquinic acid (4-CQA), 5-caffeoylquinic acid (5-CQA), 3,4-dicaffeoylquinic acid (3,4-DQA), 3,5-dicaffeoylquinic acid (3,5-DQA), and 4,5-dicaffeoylquinic acid (4,5-DQA) contents. The samples were collected from public markets and analysed using ultra-high performance liquid chromatography (UPLC). The highest concentrations of chlorogenic acids were found in yerba mate (Ilex paraguariensis), 9,2g·100g -1 , white tea (Camellia sinensis), winter's bark (Drimys winteri), green tea (Camellia sinensis), elderflower (Sambucus nigra), and Boehmeria caudata (known as assa-peixe in Brazil), 1,1g·100g -1 . The present work showcased the investigation of chlorogenic acids in a wide range of plants not yet studied in this regard and also resulted in a comparative table which explores the content of six isomers in the samples. Copyright © 2017. Published by Elsevier Ltd.

  20. Novel structure of cockroach allergen Bla g 1 has implications for allergenicity and exposure assessment

    PubMed Central

    Mueller, Geoffrey A.; Pedersen, Lars C.; Lih, Fred B.; Glesner, Jill; Moon, Andrea F.; Chapman, Martin D.; Tomer, Kenneth B.; London, Robert E.; Pomés, Anna

    2013-01-01

    Background Sensitization to cockroach allergens is a major risk factor for asthma. The cockroach allergen Bla g 1 has multiple repeats of ~100 amino acids, but the fold of the protein and the biological function are unknown. Objective To determine the structure of Bla g 1, investigate the implications for allergic disease, and standardize cockroach exposure assays. Methods Natural Bla g 1 and recombinant constructs were compared by ELISA using specific murine IgG and human IgE. The structure of Bla g 1 was determined by X-ray crystallography. Mass spectrometry and NMR were utilized to examine ligand-binding properties of the allergen. Results The structure of a recombinant Bla g 1 construct with comparable IgE and IgG reactivity to the natural allergen was solved by X-ray crystallography. The Bla g 1 repeat forms a novel fold with 6 helices. Two repeats encapsulate a large and nearly spherical hydrophobic cavity, defining the basic structural unit. Lipids in the cavity varied depending on the allergen origin. Palmitic, oleic and stearic acids were associated with nBla g 1 from cockroach frass. One Unit of Bla g 1 was equivalent to 104 ng of allergen. Conclusions Bla g 1 has a novel fold with a capacity to bind various lipids, which suggests a digestive function associated with non-specific transport of lipid molecules in cockroaches. Defining the basic structural unit of Bla g 1 facilitates the standardization of assays in absolute units for the assessment of environmental allergen exposure. PMID:23915714

  1. Reference Dosimetry for the 1992 NATO Battlefield Dosimetry Intercomparison at the Army Pulse Radiation Facility

    DTIC Science & Technology

    1993-04-01

    dosimeter using the Rh -103(n,n’) Rh - 103m reaction. Health Physics 25: 291-297, 1973. 11. Zeman, G. H. Rhodium-103 and indium-115 inelastic scattering... Rh foil 203 .... A120 3 TLD -- 17.0 -- TE-Mg ICI 205 16.1 221 93 APRF TE-Mg IC 205 17.6 223 92 CaF TLD -- 22.1 .... Average 204 17.5 222 92 +/- 1.5

  2. BaSO4:Eu as an energy independent thermoluminescent radiation dosimeter for gamma rays and C6+ ion beam

    NASA Astrophysics Data System (ADS)

    Sharma, Kanika; Bahl, Shaila; Singh, Birendra; Kumar, Pratik; Lochab, S. P.; Pandey, Anant

    2018-04-01

    BaSO4:Eu nanophosphor is delicately optimized by varying the concentration of the impurity element and compared to the commercially available thermoluminescent dosimeter (TLD) LiF:Mg,Ti (TLD-100) and by extension also to CaSO4:Dy (TLD-900) so as to achieve its maximum thermoluminescence (TL) sensitivity. Further, the energy dependence property of this barite nanophosphor is also explored at length by exposing the phosphor with 1.25 MeV of Co-60, 0.662 MeV of Cs-137, 85 MeV and 65 MeV of Carbon ion beams. Various batches of the phosphor at hand (with impurity concentrations being 0.05, 0.10, 0.20, 0.50 and 1.00 mol%) are prepared by the chemical co-precipitation method out of which BaSO4:Eu with 0.20 mol% Eu exhibits the maximum TL sensitivity. Further, the optimized nanophosphor exhibits a whopping 28.52 times higher TL sensitivity than the commercially available TLD-100 and 1.426 times higher sensitivity than TLD-900, a noteworthy linear response curve for an exceptionally wide range of doses i.e. 10 Gy to 2 kGy and a simple glow curve structure. Furthermore, when the newly optimized nanophosphor is exposed with two different energies of gamma radiations, namely 1.25 MeV of Co-60 (dose range- 10-300 Gy) and 0.662 MeV of Cs-137 (dose range- 1-300 Gy), it is observed that the shape and structure of the glow curves remain remarkably similar for different energies of radiation while the TL response curve shows little to no variation. When exposed to different energies of carbon ion beam BaSO4:Eu displays energy independence at lower doses i.e. from 6.059 to 14.497 kGy. Finally, even though energy independence is lost at higher doses, the material shows high sensitivity to higher energy (85 MeV) of carbon beam compared to the lower energy (65 MeV of C6+) and saturation is apparent only after 121.199 kGy. Therefore the present nanophosphor displays potential as an energy independent TLD.

  3. The H,G_1,G_2 photometric system with scarce observational data

    NASA Astrophysics Data System (ADS)

    Penttilä, A.; Granvik, M.; Muinonen, K.; Wilkman, O.

    2014-07-01

    The H,G_1,G_2 photometric system was officially adopted at the IAU General Assembly in Beijing, 2012. The system replaced the H,G system from 1985. The 'photometric system' is a parametrized model V(α; params) for the magnitude-phase relation of small Solar System bodies, and the main purpose is to predict the magnitude at backscattering, H := V(0°), i.e., the (absolute) magnitude of the object. The original H,G system was designed using the best available data in 1985, but since then new observations have been made showing certain features, especially near backscattering, to which the H,G function has troubles adjusting to. The H,G_1,G_2 system was developed especially to address these issues [1]. With a sufficient number of high-accuracy observations and with a wide phase-angle coverage, the H,G_1,G_2 system performs well. However, with scarce low-accuracy data the system has troubles producing a reliable fit, as would any other three-parameter nonlinear function. Therefore, simultaneously with the H,G_1,G_2 system, a two-parameter version of the model, the H,G_{12} system, was introduced [1]. The two-parameter version ties the parameters G_1,G_2 into a single parameter G_{12} by a linear relation, and still uses the H,G_1,G_2 system in the background. This version dramatically improves the possibility to receive a reliable phase-curve fit to scarce data. The amount of observed small bodies is increasing all the time, and so is the need to produce estimates for the absolute magnitude/diameter/albedo and other size/composition related parameters. The lack of small-phase-angle observations is especially topical for near-Earth objects (NEOs). With these, even the two- parameter version faces problems. The previous procedure with the H,G system in such circumstances has been that the G-parameter has been fixed to some constant value, thus only fitting a single-parameter function. In conclusion, there is a definitive need for a reliable procedure to produce

  4. Inhibition of Expression of the S100A8 Gene Encoding the S100 Calcium-Binding Protein A8 Promotes Apoptosis by Suppressing the Phosphorylation of Protein Kinase B (Akt) in Endometrial Carcinoma and HEC-1A Cells

    PubMed Central

    Liu, Chang; Xing, Guangyang; Wu, Cailiang; Zhu, Jun; Wei, Min; Liu, Dajiang; Ge, Yan; Chen, Yao; Lei, Ting

    2018-01-01

    Background The aim of this study was to investigate the expression and silencing of the S100A8 gene, which encodes the S100 calcium-binding protein A8 (S100A8), and apoptosis and phosphorylation of protein kinase B (Akt) in tissue samples of endometrial carcinoma and HEC-1A endometrial adenocarcinoma cells in vitro. Material/Methods Immunohistochemistry (IHC) was used to detect expression of the S100A8 protein in 74 tissue samples of endometrial cancer and 22 normal endometrial tissue samples. A stable S100A8 gene knockdown cell line was constructed using lentiviral packing short hairpin RNA (shRNA) transfected into HEC-1A cells. S100A8 mRNA and S100A8 protein levels were detected by quantitative reverse transcription-polymerase chain reaction (qRT-PCR) and Western blotting. The effects of expression of the S100A8 gene by endometrial cancer cells was investigated by the MTT assay, cell cycle and apoptotic assays, qRT-PCR, and Western blotting. Results IHC showed high levels of expression of S100A8 protein in endometrial carcinoma tissues, and HEC-1A adenocarcinoma cells (in G1 and G2). Increased expression of S100A8 protein was found endometrial cancer tissues compared with normal endometrial tissues (79.7% vs. 4.5%). S100A8 gene knockdown reduced cell proliferation in the HEC-1A cells compared with control cells, induced cell apoptosis, inhibited the phosphorylation of protein kinase B (Akt), and induced the expression of pro-apoptotic genes, including the cytochrome C gene, CYCS, BAD, BAX, FOXO1, FOXO3, CASP9, and CASP3. Conclusions In endometrial carcinoma cells, down-regulation of the S100A8 gene induced cell apoptosis via inhibition of the phosphorylated or active form of protein kinase B (Akt). PMID:29595187

  5. PAI-1 4G/5G polymorphism contributes to cancer susceptibility: evidence from meta-analysis.

    PubMed

    Wang, Shangqian; Cao, Qiang; Wang, Xiaoxiang; Li, Bingjie; Tang, Min; Yuan, Wanqing; Fang, Jianzheng; Qian, Jian; Qin, Chao; Zhang, Wei

    2013-01-01

    The plasminogen activator inhibitor-1 (PAI-1) is expressed in many cancer cell types and allows the modulation of cancer growth, invasion and angiogenesis. To date, studies investigated the association between a functional polymorphism in PAI-1 (4G/5G) and risk of cancer have shown inclusive results. A meta-analysis based on 25 case-control studies was performed to address this issue. Odds ratios (OR) with corresponding 95% confidence intervals (CIs) were used to assess the association. The statistical heterogeneity across studies was examined with I(2) test. Overall, a significant increased risk of cancer was associated with the PAI-1 4G/4G polymorphism for the allele contrast (4G vs. 5G: OR = 1.10, CI = 1.03-1.18, I(2) = 49.5%), the additive genetic model (4G/4G vs. 5G/5G: OR = 1.21, CI = 1.06-1.39, I(2) = 51.9%), the recessive genetic model (4G/4G vs. 4G/5G+5G/5G: OR = 1.11, CI = 1.04-1.18, I(2) = 20.8%). In the subgroup analysis by ethnicity, the results indicated that individuals with 4G/4G genotype had a significantly higher cancer risk among Caucasians (4G/4G vs. 5G/5G: OR = 1.31, 95%CI = 1.09-1.59, I(2) = 59.6%; 4G/4G vs. 4G/5G: OR = 1.12, 95%CI = 1.04-1.21, I(2) = 3.6%; recessive model: OR = 1.12, 95%CI = 1.05-1.21, I(2) = 25.3%). The results of the present meta-analysis support an association between the PAI-1 4G/5G polymorphism and increasing cancer risk, especially among Caucasians, and those with 4G allele have a high risk to develop colorectal cancer and endometrial cancer.

  6. Cardiovascular effects of anti-G suit inflation at 1 and 2 G.

    PubMed

    Montmerle, Stéphanie; Linnarsson, Dag

    2005-06-01

    We sought to determine to which pressure a full-coverage anti-G suit needs to be inflated in order to obtain the same stroke volume during a brief exposure to twice the normal gravity (2 G) as that at 1 G without anti-G suit inflation. Nine sitting subjects were studied at normal (1 G) and during 20 s of exposure to 2 G. They wore anti-G suits, which were inflated at both G-levels to the following target pressures: 0, 70, 140 and 210 mmHg. Stroke volume was computed from cardiac output, which was measured by rebreathing. Heart rate and mean arterial pressure at heart level were recorded. Inflation to 70 mmHg compensated for the decrease in stroke volume and cardiac output caused by hypergravity. Mean arterial pressure at heart level was comparable at 1 G and at 2 G and increased gradually and similarly with inflation (P<0.001) at both gravity levels. Thus, anti-G suits act by increasing both preload and afterload but the two effects counteract each other in terms of cardiac output, so that cardiac output at 2 G is maintained at its 1 G level. This effect is reached already at 70 mmHg of inflation. Greater inflation pressure further increases mean arterial pressure at heart level and compensates for the increased difference in hydrostatic pressure between heart and head in moderate hypergravity.

  7. 26 CFR 1.414(g)-1 - Definition of plan administrator.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Definition of plan administrator. 1.414(g)-1 Section 1.414(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.414(g)-1...

  8. Evaluation of the uncertainties in the TLD radiosurgery postal dose system

    NASA Astrophysics Data System (ADS)

    Campos, L. T.; Leite, S. P.; de Almeida, C. E. V.; Magalhães, L. A. G.

    2018-03-01

    Stereotactic radiosurgery is a single-fraction radiation therapy procedure for treating intracranial lesions using a stereotactic apparatus and multiple narrow beams delivered through noncoplanar isocentric arcs. To guarantee a high quality standard, a comprehensive Quality Assurance programme is extremely important to ensure that the measured dose is consistent with the tolerance considered to improve treatment quality. The Radiological Science Laboratory operates a postal audit programme in SRT and SRS. The purpose of the programme is to verify the target localization accuracy in known geometry and the dosimetric conditions of the TPS. The programme works in such a way those thermoluminescence dosimeters, consisting of LiF chips, are sent to the centre where they are to be irradiated to a certain dose. The TLD are then returned, where they are evaluated and the absorbed dose is obtained from TLDs readings. The aim of the present work is estimate the uncertainties in the process of dose determination, using experimental data.

  9. [PAL-1 5G/4G polymorphism in patients with systemic lupus erythematosus].

    PubMed

    Savov, A; Andonova, S; Tanev, D; Robeva, R; Marincheva, Ts; Tomova, A; Kumanov, Ph; Rashkov, R; Kolarov, Zl

    2014-01-01

    Systemic lupus erythematosus (SLE) is a connective tissue disease affecting predominantly women that has been widely associated with obstetric complications. Inherited thrombophilias are significant risk factors for pregnancy loss, but their role in patients with SLE, and especially in those without concomitant secondary antiphospholipid syndrome (APS) has not been clarified. The aim of the present study was to study PAI-1 5G/4G polymorphism in women with lupus. A total of 103 SLE patients as well as 69 healthy volunteers were genotyped for PAI-1 5G/4G (rs1799889). No significant differences in the PAI-1 5G/4G genotype prevalence between patients and controls were found. After exclusion of the women with secondary APS, the frequency of pregnancies and spontaneous abortions, as well as the number of live births were similar in the studied patients with different PAI-1 genotype (p> 0.05). PAI-1 5G/4G polymorphism was not significantly related to any of the lupus ACR criteria or disease activity (p > 0.05), but it could influence the platelet number in the studied patients (263.52 ± 91.10 [5G/5G genotype] versus 210.12 ± 71.79 [4G/4G genotype], p = 0.023). In conclusion, our results showed that PAI-1 4G/5G polymorphism did not worsen the reproductive outcome in SLE women without secondary APS.

  10. 26 CFR 1.665(g)-1A - Capital gain distribution.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 8 2011-04-01 2011-04-01 false Capital gain distribution. 1.665(g)-1A Section 1.665(g)-1A Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX... Beginning on Or After January 1, 1969 § 1.665(g)-1A Capital gain distribution. For any taxable year of a...

  11. 26 CFR 1.665(g)-1A - Capital gain distribution.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 8 2014-04-01 2014-04-01 false Capital gain distribution. 1.665(g)-1A Section 1.665(g)-1A Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX... Beginning on Or After January 1, 1969 § 1.665(g)-1A Capital gain distribution. For any taxable year of a...

  12. 26 CFR 1.665(g)-1A - Capital gain distribution.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 8 2012-04-01 2012-04-01 false Capital gain distribution. 1.665(g)-1A Section 1.665(g)-1A Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX... Beginning on Or After January 1, 1969 § 1.665(g)-1A Capital gain distribution. For any taxable year of a...

  13. 26 CFR 1.665(g)-1A - Capital gain distribution.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 8 2013-04-01 2013-04-01 false Capital gain distribution. 1.665(g)-1A Section 1.665(g)-1A Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX... Beginning on Or After January 1, 1969 § 1.665(g)-1A Capital gain distribution. For any taxable year of a...

  14. 26 CFR 1.665(g)-1A - Capital gain distribution.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Capital gain distribution. 1.665(g)-1A Section 1.665(g)-1A Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX... Or After January 1, 1969 § 1.665(g)-1A Capital gain distribution. For any taxable year of a trust...

  15. PAI-1 4G/5G Polymorphism Contributes to Cancer Susceptibility: Evidence from Meta-Analysis

    PubMed Central

    Li, Bingjie; Tang, Min; Yuan, Wanqing; Fang, Jianzheng; Qian, Jian; Qin, Chao; Zhang, Wei

    2013-01-01

    Background The plasminogen activator inhibitor-1 (PAI-1) is expressed in many cancer cell types and allows the modulation of cancer growth, invasion and angiogenesis. To date, studies investigated the association between a functional polymorphism in PAI-1 (4G/5G) and risk of cancer have shown inclusive results. Methods A meta-analysis based on 25 case-control studies was performed to address this issue. Odds ratios (OR) with corresponding 95% confidence intervals (CIs) were used to assess the association. The statistical heterogeneity across studies was examined with I2 test. Results Overall, a significant increased risk of cancer was associated with the PAI-1 4G/4G polymorphism for the allele contrast (4G vs. 5G: OR = 1.10, CI = 1.03–1.18, I2 = 49.5%), the additive genetic model (4G/4G vs. 5G/5G: OR = 1.21, CI = 1.06–1.39, I2 = 51.9%), the recessive genetic model (4G/4G vs. 4G/5G+5G/5G: OR = 1.11, CI = 1.04–1.18, I2 = 20.8%). In the subgroup analysis by ethnicity, the results indicated that individuals with 4G/4G genotype had a significantly higher cancer risk among Caucasians (4G/4G vs. 5G/5G: OR = 1.31, 95%CI = 1.09–1.59, I2 = 59.6%; 4G/4G vs. 4G/5G: OR = 1.12, 95%CI = 1.04–1.21, I2 = 3.6%; recessive model: OR = 1.12, 95%CI = 1.05–1.21, I2 = 25.3%). Conclusions The results of the present meta-analysis support an association between the PAI-1 4G/5G polymorphism and increasing cancer risk, especially among Caucasians, and those with 4G allele have a high risk to develop colorectal cancer and endometrial cancer. PMID:23437240

  16. G1 arrest induction represents a critical determinant for cisplatin cytotoxicity in G1 checkpoint-retaining human cancers.

    PubMed

    Un, Frank

    2007-04-01

    Cisplatin has been used effectively to treat various human cancer types; yet, the precise mechanism underlying its cytotoxicity remains unknown. In eukaryotes, progression through G1 is monitored by a checkpoint, which executes G1 arrest in the event of DNA damage to allow time for repair before initiating DNA replication. The retinoblastoma tumor suppressor gene is an integral component of the mammalian G1 checkpoint. The utility of the retinoblastoma gene as a therapeutic for human cancers has been investigated. Intriguingly, the cytotoxicity profile of the retinoblastoma gene therapy closely parallels the clinical targets of cisplatin. It prompted an investigation into the potential role of the checkpoint-induced G1 arrest in cisplatin cytotoxicity. Here, the evidence that G1 arrest induction represents a critical step in cisplatin-induced lytic path is presented. First, cisplatin-treated human cancer cells undergo a prolonged G1 arrest before dying. Second, triggering G1 arrest via infection with a recombinant adenovirus expressing the human retinoblastoma gene is sufficient to potentiate lethality in the absence of cisplatin. Third, the extent of the lethality induced correlates with the G1-arresting potential of the ectopically expressed human retinoblastoma polypeptide. Fourth, human cancer cells resistant to cisplatin do not undergo G1 arrest despite cisplatin treatment. The above mechanism may be exploited to develop therapeutics that preserve the efficacy of cisplatin yet bypass its mutagenicity associated with the formation of secondary tumors.

  17. PAI-1 mRNA expression and plasma level in rheumatoid arthritis: relationship with 4G/5G PAI-1 polymorphism.

    PubMed

    Muñoz-Valle, José Francisco; Ruiz-Quezada, Sandra Luz; Oregón-Romero, Edith; Navarro-Hernández, Rosa Elena; Castañeda-Saucedo, Eduardo; De la Cruz-Mosso, Ulises; Illades-Aguiar, Berenice; Leyva-Vázquez, Marco Antonio; Castro-Alarcón, Natividad; Parra-Rojas, Isela

    2012-12-01

    Rheumatoid arthritis (RA) is a chronic inflammatory disease affecting the synovial membrane, cartilage and bone. PAI-1 is a key regulator of the fibrinolytic system through which plasminogen is converted to plasmin. The plasmin activates the matrix metalloproteinase system, which is closely related with the joint damage and bone destruction in RA. The aim of this study was to investigate the relationship between 4G/5G PAI-1 polymorphism with mRNA expression and PAI-1 plasma protein levels in RA patients. 113 RA patients and 123 healthy subjects (HS) were included in the study. The 4G/5G PAI-1 polymorphism was determined by polymerase chain reaction-restriction fragment length polymorphism method; the PAI-1 mRNA expression was determined by real-time PCR; and the soluble PAI-1 (sPAI-1) levels were quantified using an ELISA kit. No significant differences in the genotype and allele frequencies of 4G/5G PAI-1 polymorphism were found between RA patients and HS. However, the 5G/5G genotype was the most frequent in both studied groups: RA (42%) and HS (44%). PAI-1 mRNA expression was slightly increased (0.67 fold) in RA patients with respect to HS (P = 0.0001). In addition, in RA patients, the 4G/4G genotype carriers showed increased PAI-1 mRNA expression (3.82 fold) versus 4G/5G and 5G/5G genotypes (P = 0.0001), whereas the sPAI-1 plasma levels did not show significant differences. Our results indicate that the 4G/5G PAI-1 polymorphism is not a marker of susceptibility in the Western Mexico. However, the 4G/4G genotype is associated with high PAI-1 mRNA expression but not with the sPAI-1 levels in RA patients.

  18. Protein tyrosine phosphatase 1B negatively regulates S100A9-mediated lung damage during respiratory syncytial virus exacerbations.

    PubMed

    Foronjy, R F; Ochieng, P O; Salathe, M A; Dabo, A J; Eden, E; Baumlin, N; Cummins, N; Barik, S; Campos, M; Thorp, E B; Geraghty, P

    2016-09-01

    Protein tyrosine phosphatase 1B (PTP1B) has anti-inflammatory potential but PTP1B responses are desensitized in the lung by prolonged cigarette smoke exposure. Here we investigate whether PTP1B expression affects lung disease severity during respiratory syncytial viral (RSV) exacerbations of chronic obstructive pulmonary disease (COPD). Ptp1b(-/-) mice infected with RSV exhibit exaggerated immune cell infiltration, damaged epithelial cell barriers, cytokine production, and increased apoptosis. Elevated expression of S100A9, a damage-associated molecular pattern molecule, was observed in the lungs of Ptp1b(-/-) mice during RSV infection. Utilizing a neutralizing anti-S100A9 IgG antibody, it was determined that extracellular S100A9 signaling significantly affects lung damage during RSV infection. Preexposure to cigarette smoke desensitized PTP1B activity that coincided with enhanced S100A9 secretion and inflammation in wild-type animals during RSV infection. S100A9 levels in human bronchoalveolar lavage fluid had an inverse relationship with lung function in healthy subjects, smokers, and COPD subjects. Fully differentiated human bronchial epithelial cells isolated from COPD donors cultured at the air liquid interface secreted more S100A9 than cells from healthy donors or smokers following RSV infection. Together, these findings show that reduced PTP1B responses contribute to disease symptoms in part by enhancing S100A9 expression during viral-associated COPD exacerbations.

  19. 26 CFR 1.143(g)-1 - Requirements related to arbitrage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 2 2010-04-01 2010-04-01 false Requirements related to arbitrage. 1.143(g)-1 Section 1.143(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED....143(g)-1 Requirements related to arbitrage. (a) In general. Under section 143, for an issue to be an...

  20. 26 CFR 1.414(g)-1 - Definition of plan administrator.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 5 2014-04-01 2014-04-01 false Definition of plan administrator. 1.414(g)-1 Section 1.414(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED...(g)-1 Definition of plan administrator. (a) In general. For purposes of part I of subchapter D of...

  1. 26 CFR 1.143(g)-1 - Requirements related to arbitrage.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 2 2014-04-01 2014-04-01 false Requirements related to arbitrage. 1.143(g)-1 Section 1.143(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED....143(g)-1 Requirements related to arbitrage. (a) In general. Under section 143, for an issue to be an...

  2. 26 CFR 1.414(g)-1 - Definition of plan administrator.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 5 2011-04-01 2011-04-01 false Definition of plan administrator. 1.414(g)-1 Section 1.414(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED...(g)-1 Definition of plan administrator. (a) In general. For purposes of part I of subchapter D of...

  3. 26 CFR 1.414(g)-1 - Definition of plan administrator.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 5 2012-04-01 2011-04-01 true Definition of plan administrator. 1.414(g)-1 Section 1.414(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED...(g)-1 Definition of plan administrator. (a) In general. For purposes of part I of subchapter D of...

  4. 26 CFR 1.414(g)-1 - Definition of plan administrator.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 5 2013-04-01 2013-04-01 false Definition of plan administrator. 1.414(g)-1 Section 1.414(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED...(g)-1 Definition of plan administrator. (a) In general. For purposes of part I of subchapter D of...

  5. 26 CFR 1.143(g)-1 - Requirements related to arbitrage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 2 2011-04-01 2011-04-01 false Requirements related to arbitrage. 1.143(g)-1 Section 1.143(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED....143(g)-1 Requirements related to arbitrage. (a) In general. Under section 143, for an issue to be an...

  6. 26 CFR 1.143(g)-1 - Requirements related to arbitrage.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 2 2012-04-01 2012-04-01 false Requirements related to arbitrage. 1.143(g)-1 Section 1.143(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED....143(g)-1 Requirements related to arbitrage. (a) In general. Under section 143, for an issue to be an...

  7. 26 CFR 1.143(g)-1 - Requirements related to arbitrage.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 2 2013-04-01 2013-04-01 false Requirements related to arbitrage. 1.143(g)-1 Section 1.143(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED....143(g)-1 Requirements related to arbitrage. (a) In general. Under section 143, for an issue to be an...

  8. Hydrodynamic properties of porcine bestrophin-1 in Triton X-100.

    PubMed

    Stanton, J Brett; Goldberg, Andrew F X; Hoppe, George; Marmorstein, Lihua Y; Marmorstein, Alan D

    2006-02-01

    Bestrophin-1 (Best-1) is an integral membrane protein, defects in which cause Best vitelliform macular dystrophy. Best-1 is proposed to function as a Cl- channel and/or a regulator of Ca++ channels. A tetrameric (or pentameric) stoichiometry has been reported for recombinant best-1. Using a combination of gel exclusion chromatography and velocity sedimentation we examined the quaternary structure of native best-1 and found that it migrates as a single species with a Stokes radius of 7.3 nm, sedimentation coefficient (S20,w) of 4.9, and partial specific volume (nu) of 0.80 ml/g. The mass of the protein-detergent complex is calculated to be 206 kDa, with the protein component estimated to be approximately 138 kDa. Given a monomeric mass of 68 kDa, we conclude that native best-1 solubilized with Triton X-100 is a homodimer. The differences between this observation and a prior report were examined by comparing recombinant best-1 with tissue derived best-1 using gel exclusion chromatography. Much of the recombinant best-1 eluted in the column void (Vo) fraction, unlike that extracted from RPE cells. We conclude that the minimal functional unit of best-1 is dimeric. This stoichiometry differs from that previously measured for recombinant best-1, suggesting that further studies are necessary to determine the stoichiometry of functional best-1 in RPE membranes.

  9. MCNP SIMULATION OF THE HP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeV.

    PubMed

    Freitas, B M; Martins, M M; Pereira, W W; da Silva, A X; Mauricio, C L P

    2016-09-01

    The Brazilian Instituto de Radioproteção e Dosimetria (IRD) runs a neutron individual monitoring system with a home-made TLD albedo dosemeter. It has already been characterised and calibrated in some reference fields. However, the complete energy response of this dosemeter is not known, and the calibration factors for all monitored workplace neutron fields are difficult to be obtained experimentally. Therefore, to overcome such difficulties, Monte Carlo simulations have been used. This paper describes the simulation of the HP(10) neutron response of the IRD TLD albedo dosemeter using the MCNPX transport code, for energies from thermal to 20 MeV. The validation of the MCNPX modelling is done comparing the simulated results with the experimental measurements for ISO standard neutron fields of (241)Am-Be, (252)Cf, (241)Am-B and (252)Cf(D2O) and also for (241)Am-Be source moderated with paraffin and silicone. Bare (252)Cf are used for normalisation. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. 41 CFR 101-1.100 - Scope of subpart.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 41 Public Contracts and Property Management 2 2014-07-01 2012-07-01 true Scope of subpart. 101-1... System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.100... Management Regulations System: its content, types, publication, authority, applicability, numbering...

  11. 41 CFR 101-1.100 - Scope of subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 2 2013-07-01 2012-07-01 true Scope of subpart. 101-1... System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.100... Management Regulations System: its content, types, publication, authority, applicability, numbering...

  12. 41 CFR 101-1.100 - Scope of subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 2 2010-07-01 2010-07-01 true Scope of subpart. 101-1... System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.100... Management Regulations System: its content, types, publication, authority, applicability, numbering...

  13. 41 CFR 101-1.100 - Scope of subpart.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 41 Public Contracts and Property Management 2 2012-07-01 2012-07-01 false Scope of subpart. 101-1... System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.100... Management Regulations System: its content, types, publication, authority, applicability, numbering...

  14. 41 CFR 101-1.100 - Scope of subpart.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 41 Public Contracts and Property Management 2 2011-07-01 2007-07-01 true Scope of subpart. 101-1... System FEDERAL PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 101-1.100... Management Regulations System: its content, types, publication, authority, applicability, numbering...

  15. 26 CFR 1.514(g)-1 - Business lease indebtedness.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 7 2012-04-01 2012-04-01 false Business lease indebtedness. 1.514(g)-1 Section... TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt Organizations § 1.514(g)-1 Business lease indebtedness. (a) Definition. The term business lease indebtedness means...

  16. 26 CFR 1.514(g)-1 - Business lease indebtedness.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 7 2013-04-01 2013-04-01 false Business lease indebtedness. 1.514(g)-1 Section... TAX (CONTINUED) INCOME TAXES (CONTINUED) Taxation of Business Income of Certain Exempt Organizations § 1.514(g)-1 Business lease indebtedness. (a) Definition. The term business lease indebtedness means...

  17. 26 CFR 1.404(g)-1 - Deduction of employer liability payments.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...(g)-1 Section 1.404(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.404(g)-1... employer. (c) Limitations, etc.—(1) Permissible expenses. A payment shall be deductible under section 404(g...

  18. Conformational organizations of G-quadruplexes composed of d(G(4)T(n))(3)G(4).

    PubMed

    Wong, Wan Chi; Zhuang, Jinyi; Ng, Selina Ling Ling; New, Lilian Li Lin; Hiew, Shuhui; Guo, Juanjuan; Yang, Zhaoqi; Li, Tianhu

    2010-08-01

    Structural polymorphism is one of the important issues with regard to G-quadruplexes because the structural diversity may significantly affect their biological functions in vivo and their physical property in nano-material. A series of oligonucleotides with four repeat guanines sequence [d(G(4)T(n))(3)G(4) (n=1-6)] were designed. In this study, the effects of loop length on the formation of structures of G-quadruplex were investigated through the result of CD (circular dichroism) and 20% non-denatured polyacrylamide gel electrophoresis. Our studies demonstrate that the length of loop in 100mM KCl solution could predict the conformation of G-quadruplex. Copyright 2010 Elsevier Ltd. All rights reserved.

  19. Thermoluminescence glow-curve characteristics of LiF phosphors at high doses of gamma radiation

    NASA Astrophysics Data System (ADS)

    Benny, P. G.; Khader, S. A.; Sarma, K. S. S.

    2013-05-01

    High doses of ionising radiation are becoming increasingly common for radiation-processing applications of various medical, agricultural and polymer products using gamma and electron beams. The objective of this work was to study thermoluminescence (TL) glow-curve characteristics of commonly used commercial LiF TL phosphors at high doses of radiation with a view to use them in dosimetry of radiation-processing applications. The TL properties of TLD 100 and 700 phosphors, procured from the Thermo-Scientific (previously Harshaw) company, have been studied in the dose range of 1-60 kGy. The shift in glow peaks was observed in this dose range. Integral TL responses of TLD 100 and TLD 700 were found to decrease as a linear function of dose in the range of 5-50 kGy. The paper describes initial results related to the glow-curve characteristics of these phosphors.

  20. AFRRI Reports, April-June 1990

    DTIC Science & Technology

    1990-07-01

    described in detail in the companion paper (4). In vivo dosimetry was done using Harshaw (Solon, Ohio) TLD -100 lith- ium fluoride thermoluminescent...provide replicate measurements. Two separate dosimetry tubes were developed (Fig. 1). The first contained 30 TLD cap- sules loaded in a 90-cm length...situ Dosimetry Tube 55 3 LIF TLDs In gelatin capsule TUBEB LIF TLDs Nylon Balls Steel Ball Epoxy Plug I Scale 3 cm - J FIG. I

  1. Vasoconstriction induced by G1, a G-protein-coupled oestrogen receptor1 (GPER-1) agonist, in the isolated perfused rat kidney.

    PubMed

    Kurt, Akif Hakan; Buyukafsar, Kansu

    2013-02-28

    Vascular effects of the G protein-coupled oestrogen receptor1 (GPER-1) agonist, G1 (10(-7)-5×10(-6) M), the main oestrogenic hormone, 17β-estradiol (10(-9)-10(-4) M), the NR3A1 agonist, PPT (10(-8)-10(-5) M), the NR3A2 agonist DPN (10(-8)-10(-5) M), and the classical oestrogen receptor blocker but also a GPER agonist, ICI-182780 (10(-8)-3×10(-6) M), were investigated on the perfusion pressure in the isolated rat kidney. To seek cellular mechanisms involved in GPER-1-induced signalling we tested several compounds including the inhibitors of Rho-kinase (ROCK) (Y-27632), tyrosine kinase (genistein), p38MAPK (SB203580), p44/42MAPK (PD98059), protein kinase C (PKC) (GF109203X), Jun-kinase (JNK) (SP600125), phosphatidylinositol-3-kinase (PI3K) (LY294002), Ca(2+) channels (nifedipine), GPER-1 (G15) and epidermal growth factor (EGF) receptor kinase (AG-1478). Moreover, the effect of saponin (50mg/ml) that was used for endothelium removal was explored on G1-elicited vascular action. G1, 17β-estradiol and ICI-182780 but not PPT and DPN induced vasoconstrictions in basal renal perfusion pressure. In contrast, G1 promoted vasodilatation when the perfusion pressure was elevated in advance by phenylephrine. G1-elicited vasoconstriction was not modified by endothelial removal; however, it was markedly inhibited by GPER-1 antagonist, G15. The vasoconstrictor response to G1 was also significantly attenuated by Y-27632, PD98059, SB203580, GF109203X, genistein, AG-1478, and nifedipine, but not LY294002 and SP600125. Western blotting indicated the expression of GPER-1 in renal artery, medulla and cortex of rat kidney. In conclusion, GPER-1 could substantially modulate vascular responses through a variety of signalling pathways including ROCK, PKC, p38 MAPK, p42/44 MAPK, tyrosine kinase, EGF receptor kinase and VOCC but not JNK or PI3K in isolated perfused rat kidney. Copyright © 2013 Elsevier B.V. All rights reserved.

  2. Integral cross sections for the direct excitation of the A 3 (sigma) u +, B 3 (pi) g, W 3 (delta) u, B' 3 (sigma) u -, a' 1 (sigma) u -, a 1 (pi) g, w 1 (delta) u, and C 3 (pi) u electronic states in

    NASA Technical Reports Server (NTRS)

    Johnson, P. V.; Malone, C. P.; Kanik, I.

    2005-01-01

    Integral cross sections for electron impact excitation out of the ground state (X 1(sigma)g +) to the A 3(sigma)u +, B 3(pi)g, W 3(delta)u, B' 3(sigma)u -, a' 1(sigma)u -, a 1(pi)g, w 1(delta)u, and states in N2 are reported at incident energies ranging between 10 and 100 eV. These data have been derived by integrating differential cross sections previously reported by this group. New differential cross section measurements for the a 1(pi)g state at 200 eV are also presented to extend the range of the reported integral cross sections for this state, which is responsible for the emissions of the Lyman-Birge-Hopfield band system (a 1(pi)g (rightwards arrow) X 1(sigma)g +). The present results are compared and critically evaluated against existing cross sec In general, the present cross sections are smaller than previous results at low impact energies from threshold through the excitation function peak regions. These lower cross sections have potentially significant implications on our understanding of UV emissions in the atmospheres of Earth and Titan.

  3. 26 CFR 1.404(g)-1 - Deduction of employer liability payments.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...(g)-1 Section 1.404(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY.... § 1.404(g)-1 Deduction of employer liability payments. (a) General rule. Employer liability payments... deductible under section 404(g) and this section only if the payment satisfies the conditions of section 162...

  4. 26 CFR 1.404(g)-1 - Deduction of employer liability payments.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...(g)-1 Section 1.404(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY.... § 1.404(g)-1 Deduction of employer liability payments. (a) General rule. Employer liability payments... deductible under section 404(g) and this section only if the payment satisfies the conditions of section 162...

  5. 26 CFR 1.404(g)-1 - Deduction of employer liability payments.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...(g)-1 Section 1.404(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY.... § 1.404(g)-1 Deduction of employer liability payments. (a) General rule. Employer liability payments... deductible under section 404(g) and this section only if the payment satisfies the conditions of section 162...

  6. Low-Molecular-Weight Peptides from Salmon Protein Prevent Obesity-Linked Glucose Intolerance, Inflammation, and Dyslipidemia in LDLR-/-/ApoB100/100 Mice.

    PubMed

    Chevrier, Geneviève; Mitchell, Patricia L; Rioux, Laurie-Eve; Hasan, Fida; Jin, Tianyi; Roblet, Cyril Roland; Doyen, Alain; Pilon, Geneviève; St-Pierre, Philippe; Lavigne, Charles; Bazinet, Laurent; Jacques, Hélène; Gill, Tom; McLeod, Roger S; Marette, André

    2015-07-01

    We previously reported that fish proteins can alleviate metabolic syndrome (MetS) in obese animals and human subjects. We tested whether a salmon peptide fraction (SPF) could improve MetS in mice and explored potential mechanisms of action. ApoB(100) only, LDL receptor knockout male mice (LDLR(-/-)/ApoB(100/100)) were fed a high-fat and -sucrose (HFS) diet (25 g/kg sucrose). Two groups were fed 10 g/kg casein hydrolysate (HFS), and 1 group was additionally fed 4.35 g/kg fish oil (FO; HFS+FO). Two other groups were fed 10 g SPF/kg (HFS+SPF), and 1 group was additionally fed 4.35 g FO/kg (HFS+SPF+FO). A fifth (reference) group was fed a standard feed pellet diet. We assessed the impact of dietary treatments on glucose tolerance, adipose tissue inflammation, lipid homeostasis, and hepatic insulin signaling. The effects of SPF on glucose uptake, hepatic glucose production, and inducible nitric oxide synthase activity were further studied in vitro with the use of L6 myocytes, FAO hepatocytes, and J774 macrophages. Mice fed HFS+SPF or HFS+SPF+FO diets had lower body weight (protein effect, P = 0.024), feed efficiency (protein effect, P = 0.018), and liver weight (protein effect, P = 0.003) as well as lower concentrations of adipose tissue cytokines and chemokines (protein effect, P ≤ 0.003) compared with HFS and HFS+FO groups. They also had greater glucose tolerance (protein effect, P < 0.001), lower activation of the mammalian target of rapamycin complex 1/S6 kinase 1/insulin receptor substrate 1 (mTORC1/S6K1/IRS1) pathway, and increased insulin signaling in liver compared with the HFS and HFS+FO groups. The HFS+FO, HFS+SPF, and HFS+SPF+FO groups had lower plasma triglycerides (protein effect, P = 0.003; lipid effect, P = 0.002) than did the HFS group. SPF increased glucose uptake and decreased HGP and iNOS activation in vitro. SPF reduces obesity-linked MetS features in LDLR(-/-)/ApoB(100/100) mice. The anti-inflammatory and glucoregulatory properties of SPF were

  7. Implementation of a Lateral TBI protocol in a Mexican Cancer Center

    NASA Astrophysics Data System (ADS)

    Mesa, Francisco; Esquivel, Carlos; Eng, Tony; Papanikolaou, Niko; Sosa, Modesto A.

    2008-08-01

    The development of a Lateral Total Body Irradiation protocol to be implemented at a High Specialty Medical Unit in Mexico as preparatory regimen for bone marrow transplant and treatment of several lymphomas is presented. This protocol was developed following AAPM specifications and has been validated for application at a cancer care center in United States. This protocol fundamentally focuses on patient care, avoiding instability and discomfort that may be encountered by other treatment regimes. In vivo dose verification with TLD-100 chips for each anatomical region of interest was utilized. TLD-100 chips were calibrated using a 6 MV photon beam for 10-120 cGy. Experimental results show TLD measurements with an error less than 1%. Standard deviations for calculated and measured doses for seven patients have been obtained. Data gathered for different levels of compensation indicate that a 3% measured tolerance level is acceptable. TLD point-dose measurements have been used to verify the dose beyond partial transmission lung blocks. Dose measurements beyond the lung block showed variation about 50% respects to prescribe dose. Midplane doses to the other anatomical sites were less than 2.5% respect of the prescribed dose.

  8. 41 CFR 115-1.100 - Scope of subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Scope of subpart. 115-1... System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1.100 Scope... Regulations (EPPMR), chapter 115 of the Federal Property Management Regulations System (FPMR) (41 CFR chapter...

  9. 41 CFR 128-1.100 - Scope of subpart.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Scope of subpart. 128-1... System (Continued) DEPARTMENT OF JUSTICE 1-INTRODUCTION 1.1-Regulation System § 128-1.100 Scope of... of the Federal Property Management Regulations System (FPMR) (41 CFR part 101); states its...

  10. 41 CFR 128-1.100 - Scope of subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Scope of subpart. 128-1... System (Continued) DEPARTMENT OF JUSTICE 1-INTRODUCTION 1.1-Regulation System § 128-1.100 Scope of... of the Federal Property Management Regulations System (FPMR) (41 CFR part 101); states its...

  11. 41 CFR 115-1.100 - Scope of subpart.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 41 Public Contracts and Property Management 3 2014-01-01 2014-01-01 false Scope of subpart. 115-1... System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1.100 Scope... Regulations (EPPMR), chapter 115 of the Federal Property Management Regulations System (FPMR) (41 CFR chapter...

  12. 41 CFR 115-1.100 - Scope of subpart.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Scope of subpart. 115-1... System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1.100 Scope... Regulations (EPPMR), chapter 115 of the Federal Property Management Regulations System (FPMR) (41 CFR chapter...

  13. 41 CFR 128-1.100 - Scope of subpart.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Scope of subpart. 128-1... System (Continued) DEPARTMENT OF JUSTICE 1-INTRODUCTION 1.1-Regulation System § 128-1.100 Scope of... of the Federal Property Management Regulations System (FPMR) (41 CFR part 101); states its...

  14. 41 CFR 128-1.100 - Scope of subpart.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 41 Public Contracts and Property Management 3 2011-01-01 2011-01-01 false Scope of subpart. 128-1... System (Continued) DEPARTMENT OF JUSTICE 1-INTRODUCTION 1.1-Regulation System § 128-1.100 Scope of... of the Federal Property Management Regulations System (FPMR) (41 CFR part 101); states its...

  15. 41 CFR 115-1.100 - Scope of subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Scope of subpart. 115-1... System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1.100 Scope... Regulations (EPPMR), chapter 115 of the Federal Property Management Regulations System (FPMR) (41 CFR chapter...

  16. 41 CFR 115-1.100 - Scope of subpart.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Scope of subpart. 115-1... System (Continued) ENVIRONMENTAL PROTECTION AGENCY 1-INTRODUCTION 1.1-Regulation System § 115-1.100 Scope... Regulations (EPPMR), chapter 115 of the Federal Property Management Regulations System (FPMR) (41 CFR chapter...

  17. 41 CFR 128-1.100 - Scope of subpart.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 3 2010-07-01 2010-07-01 false Scope of subpart. 128-1... System (Continued) DEPARTMENT OF JUSTICE 1-INTRODUCTION 1.1-Regulation System § 128-1.100 Scope of... of the Federal Property Management Regulations System (FPMR) (41 CFR part 101); states its...

  18. FX-25 and FX-100 Propagation Experiments.

    DTIC Science & Technology

    1982-07-01

    Radiochromic Foil Dosimetry Blue cellophane is one of the most widely used radiochromic film dosimeters.6 Blue cellophane exposed to an intense electron ...shown in Fig. 18, Appendix B. Thermoluminescent Dosimetry Lithium flouride thermoluminescent dosimeters ( TLDs ) were on a limited number of shots to...corroboration of the current distribution included radiochromic-film dosimetry , TLD arrays, and openshutter photography. Because of our discovery of the

  19. Association of MMP-1 -1607 1G/2G (rs1799750) polymorphism with primary knee osteoarthritis in the Greek population.

    PubMed

    Lepetsos, Panagiotis; Pampanos, Andreas; Kanavakis, Emmanouil; Tzetis, Maria; Korres, Dimitrios; Papavassiliou, Athanasios G; Efstathopoulos, Nicolaos

    2014-09-01

    Osteoarthritis is the most common form of arthritis with still unknown pathogenic etiology and considerable contribution of genetic factors. One of the mechanisms of cartilage degradation in osteoarthritis is enzymatic proteolysis of the extracellular matrix by metalloproteinases. MMP-1, produced by chondrocytes and synovial cells, is a major proteinase of the MMPs family. The present study aims at evaluating the association of MMP1 gene -1607 1G/2G (rs1799750) polymorphism with primary knee osteoarthritis in the Greek population. One hundred fifty five patients with primary symptomatic knee osteoarthritis participated in the study along with 139 controls. Genotypes were determined using PCR-RLFP technique. Allelic and genotypic frequencies were compared between both study groups. There was no significant association between MMP1 -1607 1G/2G polymorphism and knee osteoarthritis, in crude analysis; however, after multiple logistic regression analysis, 1G/2G was associated with reduced odds of knee osteoarthritis by 75% in males, compared to genotypes 1G/1G + 2G/2G, adjusting for age and BMI (adjusted OR: 0.25, 95% CI: 0.069, 0.910, p = 0.035). The present study shows that MMP1 -1607 1G/2G (rs1799750) polymorphism might be a risk factor for knee osteoarthritis susceptibility in the Greek population. Further investigations are needed to confirm this association in the pathogenesis of osteoarthritis. © 2014 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  20. 49 CFR 176.100 - Permit for Divisions 1.1 and 1.2 (explosive) materials.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false Permit for Divisions 1.1 and 1.2 (explosive... CARRIAGE BY VESSEL Detailed Requirements for Class 1 (Explosive) Materials § 176.100 Permit for Divisions 1.1 and 1.2 (explosive) materials. Before Divisions 1.1 and 1.2 (explosive) materials may be...

  1. 49 CFR 176.100 - Permit for Divisions 1.1 and 1.2 (explosive) materials.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 2 2011-10-01 2011-10-01 false Permit for Divisions 1.1 and 1.2 (explosive... CARRIAGE BY VESSEL Detailed Requirements for Class 1 (Explosive) Materials § 176.100 Permit for Divisions 1.1 and 1.2 (explosive) materials. Before Divisions 1.1 and 1.2 (explosive) materials may be...

  2. Beyond CD34+ cell dose: impact of method of peripheral blood hematopoietic stem cell mobilization (granulocyte-colony-stimulating factor [G-CSF], G-CSF plus plerixafor, or cyclophosphamide G-CSF/granulocyte-macrophage [GM]-CSF) on number of colony-forming unit-GM, engraftment, and Day +100 hematopoietic graft function.

    PubMed

    Alexander, Erin T; Towery, Jeanne A; Miller, Ashley N; Kramer, Cindy; Hogan, Kathy R; Squires, Jerry E; Stuart, Robert K; Costa, Luciano J

    2011-09-01

    The dose of CD34+ cells/kg in the mobilized peripheral blood product is the main determinant of neutrophil and platelet (PLT) engraftment after autologous hematopoietic stem cell transplantation (AHSCT). Whether the method of mobilization, namely, granulocyte-colony-stimulating factor (G-CSF) alone (G), G-CSF plus plerixafor (G+P), or cyclophosphamide + G/granulocyte-macrophage (GM)-CSF (Cy+G/GM), independently affects number of colony-forming unit (CFU)-GM, engraftment, and hematopoietic graft function is unknown. We used a database of AHSCT patients with multiple myeloma or lymphoma to identify three groups with different mobilization strategies receiving transplantation with similar CD34+ cell doses. Groups were compared in terms of CFU-GM, ratio of CFU-GM/CD34+, engraftment of neutrophils and PLTs, and hematopoietic graft function on Day +100. Ninety-six patients were included in the analysis, 26 G, 32 G+P, and 38 Cy+G/GM, with median cell doses of 4.21 × 10(6) , 4.11 × 10(6) , and 4.67 × 10(6) CD34+/kg, respectively (p = 0.433). There was no significant difference in number of CFU-GM between the three groups; however, the ratio of CFU-GM/CD34+ was significantly lower for G+P (p = 0.008). Median time for neutrophil engraftment was 13 days in G+P and 12 days in G and Cy+G/GM (p = 0.028), while PLT engraftment happened at a median of 14.5 days in G+P versus 12 days in G and 11 days in Cy+G/GM (p = 0.012). There was no difference in hematopoietic graft function at Day +100. Plerixafor-based mobilization is associated with slightly reduced number of CFU-GM and minimal delay in engraftment that is independent of CD34+ cell dose. Hematopoietic graft function on Day 100 is not affected by mobilization strategy. © 2011 American Association of Blood Banks.

  3. Analysis of posture and eye movement responses to Coriolis stimulation under 1 G and microgravity conditions.

    PubMed

    Sekine, Motoki; Takahashi, Masahiro; Iida, Masahiro

    2009-12-20

    To detect the effect of microgravity on vestibular responses, we conducted Coriolis stimulation experiments at 1 G and μ G. Five men with vision occluded were asked to tilt their head forward while rotating at 100 degrees/sec. Postural changes were recorded by a 3D linear accelerometer, and the distance of upper body movement was derived from recordings of linear acceleration. Eye movements were recorded by a CCD camera. For a second period after commencing head tilt, the upper body moved 10 cm in the direction of inertia input at 1 G, but it moved to the opposite direction at μ G, i.e., 4 cm in the direction of inertia force. Nystagmus peak slow-phase velocity immediately after head tilt and its attenuation process did not differ between 1 G and μ G. The strength of movement sensation and the severity of motion sickness were far weaker at μ G than at 1 G. It was concluded that inertia input is valid to induce postural and sensation responses only when the external reference is given Z axis by gravity. Vestibular ocular response may be maintained at μ G because the head reference is valid even after the external reference becomes arbitrary.

  4. Feasibility of reading LiF thermoluminescent dosimeters by electron spin resonance

    NASA Astrophysics Data System (ADS)

    Breen, S. L.; Battista, J. J.

    1999-08-01

    Lithium fluoride is a commonly used solid state dosimeter. During irradiation, electrons and holes become trapped in crystal imperfections; thermoluminescence dosimetry measures their thermally induced recombination. Electron paramagnetic resonance (EPR) spectroscopy can be used to measure the resonant absorption of microwaves by the unpaired electrons trapped in LiF. In an effort to extend the use of LiF dosimeters to smaller sizes and to the harsh environments encountered in internal dosimetry, EPR was evaluated as an alternative technique to read the radiation dose delivered to TLD-100 dosimeters. TLD-100 rods were irradiated with a 60Co source to doses of 10 Gy to 100 Gy. A radiation-induced signal (with a g-value of 2.002) could be detected only at liquid nitrogen temperatures at doses above 20 Gy. The EPR spectrum of irradiated LiF contains three components, one of which correlates positively with dose. However, the low sensitivity of the technique, and difficulty in interpreting the EPR spectrum from polycrystalline dosimeters, preclude its use as a dosimetry technique.

  5. Feasibility of reading LiF thermoluminescent dosimeters by electron spin resonance.

    PubMed

    Breen, S L; Battista, J J

    1999-08-01

    Lithium fluoride is a commonly used solid state dosimeter. During irradiation, electrons and holes become trapped in crystal imperfections; thermoluminescence dosimetry measures their thermally induced recombination. Electron paramagnetic resonance (EPR) spectroscopy can be used to measure the resonant absorption of microwaves by the unpaired electrons trapped in LiF. In an effort to extend the use of LiF dosimeters to smaller sizes and to the harsh environments encountered in internal dosimetry, EPR was evaluated as an alternative technique to read the radiation dose delivered to TLD-100 dosimeters. TLD-100 rods were irradiated with a 60Co source to doses of 10 Gy to 100 Gy. A radiation-induced signal (with a g-value of 2.002) could be detected only at liquid nitrogen temperatures at doses above 20 Gy. The EPR spectrum of irradiated LiF contains three components, one of which correlates positively with dose. However, the low sensitivity of the technique, and difficulty in interpreting the EPR spectrum from polycrystalline dosimeters, preclude its use as a dosimetry technique.

  6. Immunocytochemical localization of the ovine immunoglobulins IgA, IgG1, IgG1A and IgG2: effect of gastro-intestinal parasitism in the sheep

    PubMed Central

    Curtain, C. C.; Anderson, N.

    1971-01-01

    A study has been made of the immunocytochemical localization of IgG1, IgG2, IgG1A and IgA in the alimentary tract and associated lymph nodes of parasitized and parasite-free sheep. No immunoglobulin-containing cells were found in the abomasal mucosa of the parasite-free sheep. On the other hand, large numbers of IgG1 and IgG1A-containing cells were found in the lamina propria and at the base of the villi of the abomasum of the parasitized sheep. IgG1, IgG1A, and IgA-containing cells were found in mucosal sections from the jejunum and ileum of both parasitized and parasite-free sheep, the number of IgG1A-containing cells being sifnificantly greater in the former than in the latter. This increase was considered to be of some importance since the IgG1A subclass appears to be involved in the allergic response of the sheep to intestinal parasites. ImagesFIG. 1FIG. 2FIG. 3FIG. 4FIG. 5FIG. 6FIG. 7 PMID:4924939

  7. Digital Geologic Map of the Wallace 1:100,000 Quadrangle, Idaho

    USGS Publications Warehouse

    Lewis, Reed S.; Burmester, Russell F.; McFaddan, Mark D.; Derkey, Pamela D.; Oblad, Jon R.

    1999-01-01

    The geology of the Wallace 1:100,000 quadrangle, Idaho was compiled by Reed S. Lewis in 1997 primarily from published materials including 1983 data from Foster, Harrison's unpublished mapping done from 1975 to 1985, Hietenan's 1963, 1967, 1968, and 1984 mapping, Hobbs and others 1965 mapping, and Vance's 1981 mapping, supplemented by eight weeks of field mapping by Reed S. Lewis, Russell F. Burmester, and Mark D. McFaddan in 1997 and 1998. This geologic map information was inked onto a 1:100,000-scale greenline mylar of the topographic base map for input into a geographic information system (GIS). The resulting digital geologic map GIS can be queried in many ways to produce a variety of geologic maps. Digital base map data files (topography, roads, towns, rivers and lakes, etc.) are not included: they may be obtained from a variety of commercial and government sources. This database is not meant to be used or displayed at any scale larger than 1:100,000 (e.g., 1:62,500 or 1:24,000). The map area is located in north Idaho. The primary sources of map data are shown in figure 2 and additional sources are shown in figure 3. This open-file report describes the geologic map units, the methods used to convert the geologic map data into a digital format, the Arc/Info GIS file structures and relationships, and explains how to download the digital files from the U.S. Geological Survey public access World Wide Web site on the Internet. Mapping and compilation was completed by the Idaho Geological Survey under contract with the U.S. Geological Survey (USGS) office in Spokane, Washington. The authors would like to acknowledge the help of the following field assistants: Josh Goodman, Yvonne Issak, Jeremy Johnson and Kevin Myer. Don Winston provided help with our ongoing study of Belt stratigraphy, and Tom Frost assisted with logistical problems and sample collection. Manuscript reviews by Steve Box, Tom Frost, and Brian White are greatly appreciated. We wish to thank Karen S

  8. Study of Infrared Emission Spectroscopy for the B1Δg-A1Πu and B'1Σg+-A1Πu Systems of C2

    NASA Astrophysics Data System (ADS)

    Tang, Jian; Chen, Wang; Kawaguchi, Kentarou; Bernath, Peter F.

    2016-06-01

    Recently, we carried out the perturbation analysis of C_2 spectra and identified forbidden singlet-triplet intersystem transitions, which aroused further interest in other C_2 spectra for the many low-lying electronic states of this fundamental molecule. In 1988, the B1Δg-A1Πu and B'1Σg+-A1Πu band systems were discovered by Douay et al., who observed eight bands of the B1Δg-A1Πu system with v up to 5 for the B1Δg state and six bands of the B'1Σg+-A1Πu system with v up to 3 for the B'1Σg+ state in the Fourier transform infrared emission spectra of hydrocarbon discharges. In the work presented here, we identified twenty-four bands of the two systems, among which the B'1Σg+ v = 4 and the B1Δg v = 6, 7 and 8 vibrational levels involved in nine bands were studied for the first time. A direct global analysis with Dunham parameters was carried out satisfactorily for the B1Δg-A1Πu system except for a small perturbation in the B1Δg v = 6 level. The calculated rovibrational term energies up to B1Δg v = 12 showed that the level crossing between the B1Δg and d3Πg states is responsible for many of the prominent perturbations in the Swan system observed previously. Nineteen lines of the B1Δg-a3Πu forbidden transitions were identified and the off-diagonal spin-orbit interaction constant AdB between d3Πg and B1Δg was derived as 8.3(1) wn. For the B'1Σg+-A1Πu system, only individual band analyses for each vibrational level in the B'1Σg+ state could be done satisfactorily and Dunham parameters obtained from these effective parameters showed that the anharmonic vibrational constant ω_e x_e is anomalously small (nearly zero). Inspection of the RKR potential curves for the B'1Σg+ and X1Σg+ states revealed that an avoided crossing may occur around 30000 wn, which is responsible for the anomalous molecular constants in these two states. W. Chen, K. Kawaguchi, P. F. Bernath, and J. Tang, J. Chem. Phys., 141, 064317 (2015) M. Douay, R. Nietmann and P. F. Bernath

  9. Placental Malaria Induces Variant-Specific Antibodies of the Cytophilic Subtypes Immunoglobulin G1 (IgG1) and IgG3 That Correlate with Adhesion Inhibitory Activity

    PubMed Central

    Elliott, Salenna R.; Brennan, Amy K.; Beeson, James G.; Tadesse, Eyob; Molyneux, Malcolm E.; Brown, Graham V.; Rogerson, Stephen J.

    2005-01-01

    Antibodies targeting variant antigens on the surfaces of chondroitin sulfate A (CSA)-binding malaria-infected erythrocytes have been linked to protection against the complications of malaria in pregnancy. We examined the isotype/subtype profiles of antibodies that bound to variant surface antigens expressed by CSA-adherent Plasmodium falciparum in pregnant Malawian women with and without histologically defined placental malaria. Women in their first pregnancy with placental malaria produced significantly greater amounts of immunoglobulin G1 (IgG1) and IgG3 reactive with surface antigens of malaria-infected erythrocytes than uninfected women of the same gravidity. IgG1 and IgG3 levels in infected and control women in later pregnancies were similar to those in infected women in their first pregnancy. Levels of IgG2 and IgG4 were similarly low in infected and uninfected women of all gravidities. IgM that bound to the surface of CSA-adherent P. falciparum occurred in all groups of women and malaria-naïve controls. There was a significant correlation between IgG1 and IgG3 levels, indicating that women usually produced both subtypes. Levels of IgG1 and IgG3 correlated with the ability of serum or plasma to inhibit parasite adhesion to CSA. Taken together, these data suggest that IgG1 and IgG3 dominate the IgG response to placental-type variant surface antigens. They may function by blocking parasite adhesion to placental CSA, but given their cytophilic nature, they might also opsonize malaria-infected erythrocytes for interaction with Fc receptors on phagocytic cells. PMID:16113309

  10. Energy dependence of the response of lithium fluoride TLD rods in high energy electron fields.

    PubMed

    Holt, J G; Edelstein, G R; Clark, T E

    1975-07-01

    The energy dependence of lithium fluoride dosemeters is a complicated function of energy as well as of cavity size. In the application of TLD to charged particle dosimetry, a cavity perturbation effect may exist even though the ratios of the mass stopping powers are constant over the energies encountered. This effect was investigated for lithium fluoride rods in electron fields ranging in energy from 2-5 to 20 MeV. A 13% change of TL response per unit of absorbed dose was measured over that energy range. A semi-empirical theory was developed to account for the cavity effect, using Burlin cavity theory as a starting point. The agreement between theory and measurement is satisfactory.

  11. Deployment Health

    DTIC Science & Technology

    2006-08-11

    thermo luminescent dosimeter ( TLD badge)) are required for performing specific tasks in a safe manner while deployed, personnel must be trained on the...monitoring devices (e.g., thermo luminescent dosimeter ( TLD badge)) as required by occupational specialty of personnel. (E4.A1.1.5.) 5.5.8 X X...assigned, attached, on temporary duty, or temporary additional duty to deployed units. Report the data electronically to the DMDC (at the SECRET level

  12. 500 km unrepeatered 200 Gbit·s-1 transmission over a G.652-compliant ultra-low loss fiber only

    NASA Astrophysics Data System (ADS)

    Gainov, V. V.; Gurkin, N. V.; Lukinih, S. N.; Shikhaliev, I. I.; Skvortsov, P. I.; Makovejs, S.; Akopov, S. G.; Ten, S. Y.; Nanii, O. E.; Treshchikov, V. N.

    2015-06-01

    In this work we experimentally demonstrate 200 Gb·s-1 (2  ×  100G) unrepeatered transmission over 502.1 km using a dual polarization quadrature phase-shift-keyed (DP-QPSK) format and real-time processing. Such ultra-long distance is enabled by the use of high-performance 100G DP-QPSK transponders (the required optical signal-to-noise ratio is 12 dB), Corning® SMF-28® ULL fiber (the average attenuation of the spools used in this experiment ~0.160 dB km-1), and optimization of remotely pumped optical amplifiers, bidirectional Raman amplifiers, and dispersion precompensation.

  13. Spin dependent structure function g1 of the deuteron and the proton

    NASA Astrophysics Data System (ADS)

    Klostermann, L.

    1995-05-01

    This thesis presents a study on the spin structure of the nucleon, via deep inelastic scattering (DIS) of polarized muons on polarized proton and deuterium targets. The work was done in the Spin Muon Collaboration (SMC) at CERN in Geneva. From the asymmetry in the scattering cross section for nucleon and lepton spins parallel and anti-parallel, one can determine the spin dependent structure function g(sub 1), which contains information on the quark and gluon spin distribution functions. The interpretation in the frame work of the quark parton model (QPM) of earlier results on g(sub 1, sup d) by the European Muon Collaboration (EMC), gave an indication that only a small fraction of the proton spin, compatible with zero, is carried by the spins of the constituent quarks. The SMC was set up to check this unexpected result with improved accuracy, and to combine measurements of g(sub 1, sup p) and g(sub 1, sup d) to test a fundamental sum rule in quantum chromodynamics (QCD), the Bjorken sum rule. The SMC results presented in this thesis are based on data taken in 1992 using a polarized deuterium target and polarized muons with an incident energy of 100 GeV, and 1993 data with a proton target and an incident muon energy of 190 GeV. Using all available data, the fundamental Bjorken sum rule has now been verified at the one standard deviation level to within 16% of its theoretical value.

  14. 4G/5G Plasminogen Activator Inhibitor-1 Polymorphisms and Haplotypes Are Associated with Pneumonia

    PubMed Central

    Yende, Sachin; Angus, Derek C.; Ding, Jingzhong; Newman, Anne B.; Kellum, John A.; Li, Rongling; Ferrell, Robert E.; Zmuda, Joseph; Kritchevsky, Stephen B.; Harris, Tamara B.; Garcia, Melissa; Yaffe, Kristine; Wunderink, Richard G.

    2007-01-01

    Rationale: Plasminogen activator inhibitor (PAI)-1 inhibits urokinase and tissue plasminogen activator, required for host response to infection. Whether variation within the PAI-1 gene is associated with increased susceptibility to infection is unknown. Objectives: To ascertain the role of the 4G/5G polymorphism and other genetic variants within the PAI-1 gene. We hypothesized that variants associated with increased PAI-1 expression would be associated with an increased occurrence of community-acquired pneumonia (CAP). Methods: Longitudinal analysis (>12 yr) of the Health, Aging, and Body Composition cohort, aged 65–74 years at start of analysis. Measurements and Main Results: We genotyped the 4G/5G PAI-1 polymorphism and six additional single nucleotide polymorphisms. Of the 3,075 subjects, 272 (8.8%) had at least one hospitalization for CAP. Among whites, variants at the PAI4G,5G, PAI2846, and PAI7343 sites had higher risk of CAP (P = 0.018, 0.021, and 0.021, respectively). At these sites, variants associated with higher PAI-1 expression were associated with increased CAP susceptibility. Compared with the 5G/5G genotypes at PAI4G,5G site, the 4G/4G and 4G/5G genotypes were associated with a 1.98-fold increased risk of CAP (95% confidence interval, 1.2–3.2; P = 0.006). In whole blood stimulation assay, subjects with a 4G allele had 3.3- and 1.9-fold increased PAI-1 expression (P = 0.043 and 0.034, respectively). In haplotype analysis, the 4G/G/C/A haplotype at the PAI4G,5G, PAI2846, PAI4588, and PAI7343 single nucleotide polymorphisms was associated with higher CAP susceptibility, whereas the 5G/G/C/A haplotype was associated with lower CAP susceptibility. No associations were seen among blacks. Conclusions: Genotypes associated with increased expression of PAI-1 were associated with increased susceptibility to CAP in elderly whites. PMID:17761618

  15. Collisional relaxation of O2(X^3Σ _g^ -, υ = 1) and O2(a1Δg, υ = 1) by atmospherically relevant species

    NASA Astrophysics Data System (ADS)

    Pejaković, Dušan A.; Campbell, Zachary; Kalogerakis, Konstantinos S.; Copeland, Richard A.; Slanger, Tom G.

    2011-09-01

    Laboratory measurements are reported of the rate coefficient for collisional removal of O2(X^3Σ _g^ -, υ = 1) by O(3P), and the rate coefficients for removal of O2(a1Δg, υ = 1) by O2, CO2, and O(3P). A two-laser method is employed, in which the pulsed output of the first laser at 285 nm photolyzes ozone to produce oxygen atoms and O2(a1Δg, υ = 1), and the output of the second laser detects O2(a1Δg, υ = 1) via resonance-enhanced multiphoton ionization. The kinetics of O2(X^3Σ _g^ -, υ = 1) + O(3P) relaxation is inferred from the temporal evolution of O2(a1Δg, υ = 1), an approach enabled by the rapid collision-induced equilibration of the O2(X^3Σ _g^ -, υ = 1) and O2(a1Δg, υ = 1) populations in the system. The measured O2(X^3Σ _g^ -, υ = 1) + O(3P) rate coefficient is (2.9 ± 0.6) × 10-12 cm3 s-1 at 295 K and (3.4 ± 0.6) × 10-12 cm3 s-1 at 240 K. These values are consistent with the previously reported result of (3.2 ± 1.0) × 10-12 cm3 s-1, which was obtained at 315 K using a different experimental approach [K. S. Kalogerakis, R. A. Copeland, and T. G. Slanger, J. Chem. Phys. 123, 194303 (2005)]. For removal of O2(a1Δg, υ = 1) by O(3P), the upper limits for the rate coefficient are 4 × 10-13 cm3 s-1 at 295 K and 6 × 10-13 cm3 s-1 at 240 K. The rate coefficient for removal of O2(a1Δg, υ = 1) by O2 is (5.6 ± 0.6) × 10-11 cm3 s-1 at 295 K and (5.9 ± 0.5) × 10-11 cm3 s-1 at 240 K. The O2(a1Δg, υ = 1) + CO2 rate coefficient is (1.5 ± 0.2) × 10-14 cm3 s-1 at 295 K and (1.2 ± 0.1) × 10-14 cm3 s-1 at 240 K. The implications of the measured rate coefficients for modeling of atmospheric emissions are discussed.

  16. Comprehensive phenotypic analysis of knockout mice deficient in cyclin G1 and cyclin G2

    PubMed Central

    Ohno, Shouichi; Ikeda, Jun-ichiro; Naito, Yoko; Okuzaki, Daisuke; Sasakura, Towa; Fukushima, Kohshiro; Nishikawa, Yukihiro; Ota, Kaori; Kato, Yorika; Wang, Mian; Torigata, Kosuke; Kasama, Takashi; Uchihashi, Toshihiro; Miura, Daisaku; Yabuta, Norikazu; Morii, Eiichi; Nojima, Hiroshi

    2016-01-01

    Cyclin G1 (CycG1) and Cyclin G2 (CycG2) play similar roles during the DNA damage response (DDR), but their detailed roles remain elusive. To investigate their distinct roles, we generated knockout mice deficient in CycG1 (G1KO) or CycG2 (G2KO), as well as double knockout mice (DKO) deficient in both proteins. All knockouts developed normally and were fertile. Generation of mouse embryonic fibroblasts (MEFs) from these mice revealed that G2KO MEFs, but not G1KO or DKO MEFs, were resistant to DNA damage insults caused by camptothecin and ionizing radiation (IR) and underwent cell cycle arrest. CycG2, but not CycG1, co-localized with γH2AX foci in the nucleus after γ-IR, and γH2AX-mediated DNA repair and dephosphorylation of CHK2 were delayed in G2KO MEFs. H2AX associated with CycG1, CycG2, and protein phosphatase 2A (PP2A), suggesting that γH2AX affects the function of PP2A via direct interaction with its B’γ subunit. Furthermore, expression of CycG2, but not CycG1, was abnormal in various cancer cell lines. Kaplan–Meier curves based on TCGA data disclosed that head and neck cancer patients with reduced CycG2 expression have poorer clinical prognoses. Taken together, our data suggest that reduced CycG2 expression could be useful as a novel prognostic marker of cancer. PMID:27982046

  17. 26 CFR 1.415(g)-1 - Disqualification of plans and trusts.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 5 2013-04-01 2013-04-01 false Disqualification of plans and trusts. 1.415(g)-1 Section 1.415(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED...(g)-1 Disqualification of plans and trusts. (a) Disqualification of plans—(1) In general. Under...

  18. 26 CFR 1.415(g)-1 - Disqualification of plans and trusts.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 5 2011-04-01 2011-04-01 false Disqualification of plans and trusts. 1.415(g)-1 Section 1.415(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED...(g)-1 Disqualification of plans and trusts. (a) Disqualification of plans—(1) In general. Under...

  19. 26 CFR 1.404(g)-1 - Deduction of employer liability payments.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 5 2012-04-01 2011-04-01 true Deduction of employer liability payments. 1.404(g)-1 Section 1.404(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY.... § 1.404(g)-1 Deduction of employer liability payments. (a) General rule. Employer liability payments...

  20. 26 CFR 1.415(g)-1 - Disqualification of plans and trusts.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 5 2014-04-01 2014-04-01 false Disqualification of plans and trusts. 1.415(g)-1 Section 1.415(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED...(g)-1 Disqualification of plans and trusts. (a) Disqualification of plans—(1) In general. Under...

  1. Plasminogen activator inhibitor-1 4G/5G gene polymorphism and primary open-angle glaucoma

    PubMed Central

    Weger, Martin; Faschinger, Christoph; Schmut, Otto; Renner, Wilfried

    2008-01-01

    Purpose Alterations of the plasmin system have been suggested to participate in the multifactorial pathogenesis of primary open-angle glaucoma (POAG). The main physiological inhibitor of the plasmin system is plasminogen activator inhibitor-1 (PAI-1), which leads to decreased degradation of extracellular material. Interestingly, elevated PAI-1 levels in the aqueous humor of patients with POAG have been reported. A common polymorphism within the promoter region (PAI-1 4G/5G) has previously been shown to reduce the gene transcription rate of PAI-1. The purpose of the present study was to investigate a hypothesized association between PAI-1 4G/5G and the presence of POAG in a Caucasian population. Methods The present case-control study comprised 212 unrelated patients with POAG and 212 healthy control subjects, matched for age and sex. Genotyping of PAI-1 4G/5G polymorphisms was done using polymerase chain reaction. Results Allelic frequencies and genotype distributions of PAI-1 4G/5G did not significantly differ between patients with POAG and control subjects (PAI-1 4G/5G: 29.7% versus 29.7%). Presence of the PAI-1 4G-allele was associated with a nonsignificant odds ratio of 0.98 (95% confidence interval: 0.74–1.30) for POAG. Conclusions Our data suggest that PAI-1 4G/5G itself is unlikely to be a major risk factor among Caucasian patients with POAG. PMID:18615155

  2. Angular and radial dependence of the energy response factor for LIF-TLD micro-rods in 125L permanent implant source.

    PubMed

    Mobit, Paul; Badragan, Iulian

    2006-01-01

    EGSnrc Monte Carlo simulations were used to calculate the angular and radial dependence of the energy response factor for LiF-thermoluminescence dosemeters (TLDs) irradiated with a commercially available (125)I permanent brachytherapy source. The LiF-TLDs were modelled as cylindrical micro-rods of length 6 mm and with diameters of 1 mm and 5 mm. The results show that for a LiF-TLD micro-rod of 1 mm diameter, the energy response relative to (60)Co gamma rays is 1.406 +/- 0.3% for a polar angle of 90 degrees and radial distance of 1.0 cm. When the diameter of the micro-rod is increased from 1 to 5 mm, the energy response decreases to 1.32 +/- 0.3% at the same point. The variation with position of the energy response factor is not >5% in a 6 cm x 6 cm x 6 cm calculation grid for the 5 mm diameter micro-rod. The results show that there is a change in the photon spectrum with angle and radial distance, which causes the variation of the energy response.

  3. Influence of plasminogen activator inhibitor-1 (SERPINE1) 4G/5G polymorphism on circulating SERPINE-1 antigen expression in HCC associated with viral infection.

    PubMed

    Divella, Rosa; Mazzocca, Antonio; Gadaleta, Cosimo; Simone, Giovanni; Paradiso, Angelo; Quaranta, Michele; Daniele, Antonella

    2012-01-01

    Hepatocarcinogenesis is heavily influenced by chronic hepatitis B (HBV) and C (HCV) infection. Elevated levels of plasminogen activator inhibitor-1 (SERPINE1/PAI-1) have been reported in patients with hepatocellular carcinoma (HCC) associated with viral infection. The gene encoding SERPINE1 is highly polymorphic and the frequently associated 4/5 guanosine (4G/5G) polymorphism in the gene promoter may influence its expression. Here, we investigated the distribution of genotypes and the frequency of alleles of the 4G/5G polymorphism in patients with HCC, the influence of the 4G/5G polymorphism on plasma SERPINE1 levels and its association with viral infection. A total of 75 patients with HCC were enrolled: 32 (42.6%) were HBV(+)/HCV(+), 11 (14.6%) were only HCV(+), and 32 (42.6%) were negative for both viruses. A control group of healthy donors was also enrolled (n=50). SERPINE1 plasma concentrations were determined by ELISA and the detection of the promoter 4G/5G polymorphism was performed by an allele-specific PCR analysis. We found that the frequency of both the 4G/4G genotype (p=0.02) and the 4G allele (p=0.006) were significantly higher in patients with HCC compared to the control group, and particularly higher in patients with HCC co-infected with HBV(+)/HCV(+) than in those with no viral infection. We also found that patients with the 4G/4G genotype had significantly higher plasma SERPINE1 protein levels when compared with patients with the 4G/5G or 5G/5G genotype (p<0.001). Differences in frequency of 4G allele and genetic variability of 4G/5G SERPINE1 polymorphism with a higher level of SERPINE1 protein in patients with HCC with HBV(+)/HCV(+) than those without infection, suggest the presence of two distinct pathogenic mechanisms in hepatocarcinogenesis, depending on the etiology.

  4. Distinguishing Echinococcus granulosus sensu stricto genotypes G1 and G3 with confidence: A practical guide.

    PubMed

    Kinkar, Liina; Laurimäe, Teivi; Acosta-Jamett, Gerardo; Andresiuk, Vanessa; Balkaya, Ibrahim; Casulli, Adriano; Gasser, Robin B; González, Luis Miguel; Haag, Karen L; Zait, Houria; Irshadullah, Malik; Jabbar, Abdul; Jenkins, David J; Manfredi, Maria Teresa; Mirhendi, Hossein; M'rad, Selim; Rostami-Nejad, Mohammad; Oudni-M'rad, Myriam; Pierangeli, Nora Beatriz; Ponce-Gordo, Francisco; Rehbein, Steffen; Sharbatkhori, Mitra; Kia, Eshrat Beigom; Simsek, Sami; Soriano, Silvia Viviana; Sprong, Hein; Šnábel, Viliam; Umhang, Gérald; Varcasia, Antonio; Saarma, Urmas

    2018-06-21

    Cystic echinococcosis (CE), a zoonotic disease caused by tapeworms of the species complex Echinococcus granulosus sensu lato, represents a substantial global health and economic burden. Within this complex, E. granulosus sensu stricto (genotypes G1 and G3) is the most frequent causative agent of human CE. Currently, there is no fully reliable method for assigning samples to genotypes G1 and G3, as the commonly used mitochondrial cox1 and nad1 genes are not sufficiently consistent for the identification and differentiation of these genotypes. Thus, a new genetic assay is required for the accurate assignment of G1 and G3. Here we use a large dataset of near-complete mtDNA sequences (n = 303) to reveal the extent of genetic variation of G1 and G3 on a broad geographical scale and to identify reliable informative positions for G1 and G3. Based on extensive sampling and sequencing data, we developed a new method, that is simple and cost-effective, to designate samples to genotypes G1 and G3. We found that the nad5 is the best gene in mtDNA to differentiate between G1 and G3, and developed new primers for the analysis. Our results also highlight problems related to the commonly used cox1 and nad1. To guarantee consistent identification of G1 and G3, we suggest using the sequencing of the nad5 gene region (680 bp). This region contains six informative positions within a relatively short fragment of the mtDNA, allowing differentiation of G1 and G3 with confidence. Our method offers clear advantages over the previous ones, providing a significantly more consistent means to distinguish G1 and G3 than the commonly used cox1 and nad1. Copyright © 2018. Published by Elsevier B.V.

  5. First detection of Echinococcus granulosus sensu stricto (G1) in dogs in central Sudan.

    PubMed

    Omer, Rihab Ali; Daugschies, Arwid; Gawlowska, Sandra; Elnahas, Ayman; Kern, Peter; Bashir, Sofia; Ali, Mohammed Sir Alkhatim; Osman, Amin; Romig, Thomas

    2018-05-01

    Eighty-four stray dogs shot as a part of a governmental rabies control program in two neighboring towns of central Sudan were examined for the presence of Echinococcus spp. and other intestinal helminths. Echinococcus worms were identified to species level by PCR and gene sequencing. For comparative reasons, rectal content of the necropsied dogs was examined for helminth eggs and subjected to copro-PCR for Echinococcus. At necropsy, 51.2% (43/84) of the dogs harbored Echinococcus canadensis (G6/7) worms with worm burdens ranging from 22,000 to 80,000. Dipylidiun caninum was found in 53.6% of the dogs. At coproscopy, taeniid eggs were found in 37 of the 43 dogs which were positive for Echinococcus at necropsy, but none in the 41 necropsy-negative dogs. In addition, 58% of the rectal samples contained eggs of Toxocara spp., 34.5% eggs of Trichuris spp. (34.5%), and 26% eggs of Ancylostoma caninum. Copro-PCR gave positive results for E. canadensis with 97.5% (39/40) of nonhibiting samples from the necropsy positive dogs; the one remaining dog tested positive for E. granulosus sensu stricto (G1), whose partial cox1 and nad1 sequences showed a 100% identity with various reference sequences of the G1 genotype. 100% of 38 non-inhibited samples taken from the necropsy-negative dogs were also negative in copro-PCR. This is the first study which combines prevalence and genetic identification of Echinococcus spp. in dogs of Sudan. Together with a recent report from cattle, it confirms the autochthonous presence, at low level, of E. granulosus sensu stricto in Central Sudan.

  6. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  7. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  8. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set...

  9. Determination of aflatoxins B1, B2, G1 and G2 in spices using a multifunctional column clean-up.

    PubMed

    Akiyama, H; Goda, Y; Tanaka, T; Toyoda, M

    2001-10-12

    A rapid and simple method using a multifunctional column, which contains lipophilic and charged active sites, was developed to analyse aflatoxins B1, B2, G1 and G2 in various spices, such as red pepper and nutmeg. After extraction by acetonitrile:water (9:1) and clean-up using MultiSep #228 column, the aflatoxins and aflatoxin-TFA derivatives are determined using LC with fluorescence detection. Recoveries of each aflatoxin B1, B2, G1 and G2 spiked to red pepper, white pepper, black pepper, nutmeg and tear grass at the level of 10 ng/g were over 80-85% in all instances. The minimum detectable concentration for aflatoxins in red pepper was 0.5 ng/g.

  10. Quark-hadron duality in spin structure functions g1p and g1d

    NASA Astrophysics Data System (ADS)

    Bosted, P. E.; Dharmawardane, K. V.; Dodge, G. E.; Forest, T. A.; Kuhn, S. E.; Prok, Y.; Adams, G.; Amarian, M.; Ambrozewicz, P.; Anghinolfi, M.; Asryan, G.; Avakian, H.; Bagdasaryan, H.; Baillie, N.; Ball, J. P.; Baltzell, N. A.; Barrow, S.; Batourine, V.; Battaglieri, M.; Beard, K.; Bedlinskiy, I.; Bektasoglu, M.; Bellis, M.; Benmouna, N.; Biselli, A. S.; Bonner, B. E.; Bouchigny, S.; Boiarinov, S.; Bradford, R.; Branford, D.; Brooks, W. K.; Bültmann, S.; Burkert, V. D.; Butuceanu, C.; Calarco, J. R.; Careccia, S. L.; Carman, D. S.; Carnahan, B.; Cazes, A.; Chen, S.; Cole, P. L.; Collins, P.; Coltharp, P.; Cords, D.; Corvisiero, P.; Crabb, D.; Crannell, H.; Crede, V.; Cummings, J. P.; Masi, R. De; Devita, R.; Sanctis, E. De; Degtyarenko, P. V.; Denizli, H.; Dennis, L.; Deur, A.; Djalali, C.; Donnelly, J.; Doughty, D.; Dragovitsch, P.; Dugger, M.; Dytman, S.; Dzyubak, O. P.; Egiyan, H.; Egiyan, K. S.; Elouadrhiri, L.; Eugenio, P.; Fatemi, R.; Fedotov, G.; Feuerbach, R. J.; Funsten, H.; Garçon, M.; Gavalian, G.; Gilfoyle, G. P.; Giovanetti, K. L.; Girod, F. X.; Goetz, J. T.; Golovatch, E.; Gonenc, A.; Gothe, R. W.; Griffioen, K. A.; Guidal, M.; Guillo, M.; Guler, N.; Guo, L.; Gyurjyan, V.; Hadjidakis, C.; Hafidi, K.; Hakobyan, R. S.; Hardie, J.; Heddle, D.; Hersman, F. W.; Hicks, K.; Hleiqawi, I.; Holtrop, M.; Huertas, M.; Hyde-Wright, C. E.; Ilieva, Y.; Ireland, D. G.; Ishkhanov, B. S.; Isupov, E. L.; Ito, M. M.; Jenkins, D.; Jo, H. S.; Joo, K.; Juengst, H. G.; Keith, C.; Kellie, J. D.; Khandaker, M.; Kim, K. Y.; Kim, K.; Kim, W.; Klein, A.; Klein, F. J.; Klusman, M.; Kossov, M.; Kramer, L. H.; Kubarovsky, V.; Kuhn, J.; Kuleshov, S. V.; Lachniet, J.; Laget, J. M.; Langheinrich, J.; Lawrence, D.; Li, Ji; Lima, A. C. S.; Livingston, K.; Lu, H.; Lukashin, K.; MacCormick, M.; Manak, J. J.; Markov, N.; McAleer, S.; McKinnon, B.; McNabb, J. W. C.; Mecking, B. A.; Mestayer, M. D.; Meyer, C. A.; Mibe, T.; Mikhailov, K.; Minehart, R.; Mirazita, M.; Miskimen, R.; Mokeev, V.; Morand, L.; Morrow, S. A.; Moteabbed, M.; Mueller, J.; Mutchler, G. S.; Nadel-Turonski, P.; Napolitano, J.; Nasseripour, R.; Niccolai, S.; Niculescu, G.; Niculescu, I.; Niczyporuk, B. B.; Niroula, M. R.; Niyazov, R. A.; Nozar, M.; O'Rielly, G. V.; Osipenko, M.; Ostrovidov, A. I.; Park, K.; Pasyuk, E.; Paterson, C.; Philips, S. A.; Pierce, J.; Pivnyuk, N.; Pocanic, D.; Pogorelko, O.; Polli, E.; Pozdniakov, S.; Preedom, B. M.; Price, J. W.; Protopopescu, D.; Qin, L. M.; Raue, B. A.; Riccardi, G.; Ricco, G.; Ripani, M.; Ronchetti, F.; Rosner, G.; Rossi, P.; Rowntree, D.; Rubin, P. D.; Sabatié, F.; Salgado, C.; Santoro, J. P.; Sapunenko, V.; Schumacher, R. A.; Serov, V. S.; Sharabian, Y. G.; Shaw, J.; Shvedunov, N. V.; Skabelin, A. V.; Smith, E. S.; Smith, L. C.; Sober, D. I.; Stavinsky, A.; Stepanyan, S. S.; Stepanyan, S.; Stokes, B. E.; Stoler, P.; Strauch, S.; Suleiman, R.; Taiuti, M.; Taylor, S.; Tedeschi, D. J.; Thoma, U.; Thompson, R.; Tkabladze, A.; Tkachenko, S.; Todor, L.; Tur, C.; Ungaro, M.; Vineyard, M. F.; Vlassov, A. V.; Weinstein, L. B.; Weygand, D. P.; Williams, M.; Wolin, E.; Wood, M. H.; Yegneswaran, A.; Yun, J.; Zana, L.; Zhang, J.; Zhao, B.; Zhao, Z.

    2007-03-01

    New measurements of the spin structure functions of the proton and deuteron g1p(x,Q2) and g1d(x,Q2) in the nucleon resonance region are compared with extrapolations of target-mass-corrected next-to-leading-order (NLO) QCD fits to higher energy data. Averaged over the entire resonance region (W<2 GeV), the data and QCD fits are in good agreement in both magnitude and Q2 dependence for Q2>1.7 GeV2/c2. This “global” duality appears to result from cancellations among the prominent “local” resonance regions: in particular strong σ3/2 contributions in the Δ(1232) region appear to be compensated by strong σ1/2 contributions in the resonance region centered on 1.5 GeV. These results are encouraging for the extension of NLO QCD fits to lower W and Q2 than have been used previously.

  11. Molecular Characterization of Echinococcus granulosus Cysts in North Indian Patients: Identification of G1, G3, G5 and G6 Genotypes

    PubMed Central

    Sharma, Monika; Sehgal, Rakesh; Fomda, Bashir Ahmad; Malhotra, Anil; Malla, Nancy

    2013-01-01

    Background Cystic echinococcosis (CE) caused by the Echinococcus granulosus, is a major public health problem worldwide, including India. The different genotypes of E. granulosus responsible for human hydatidosis have been reported from endemic areas throughout the world. However, the genetic characterization of E. granulosus infecting the human population in India is lacking. The aim of study was to ascertain the genotype(s) of the parasite responsible for human hydatidosis in North India. Methodology/Principal Findings To study the transmission patterns of E. granulosus, genotypic analysis was performed on hydatid cysts obtained from 32 cystic echinococcosis (CE) patients residing in 7 different states of North India. Mitochondrial cytochrome c oxidase subunit1 (cox1) sequencing was done for molecular identification of the isolates. Most of the CE patients (30/32) were found to be infected with hydatid cyst of either G3 (53.1%) or G1 (40.62%) genotype and one each of G5 (cattle strain) and G6 (camel strain) genotype. Conclusions/Significance These findings demonstrate the zoonotic potential of G1 (sheep strain) and G3 (buffalo strain) genotypes of E. granulosus as these emerged as predominant genotypes infecting the humans in India. In addition to this, the present study reports the first human CE case infected with G5 genotype (cattle strain) in an Asian country and presence of G6 genotype (camel strain) in India. The results may have important implications in the planning of control strategies for human hydatidosis. PMID:23785531

  12. 26 CFR 1.402(g)-1 - Limitation on exclusion for elective deferrals.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... 1.402(g)-1 Section 1.402(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Pension, Profit-Sharing, Stock Bonus Plans, Etc. § 1.402(g)-1... section 402(a)(8) (before applying the limits of section 402(g) or this section). (2) Any employer...

  13. Calibration of mass and conventional mass of weights 2 kg, 1 kg, 200 g, 50 g, 1 g and 200 mg

    NASA Astrophysics Data System (ADS)

    Becerra, Luis Omar; Peña, Luis Manuel; Escalante Vargas, Boris; Cori Almonte, Luz; Martín Quiroga Rojas, Aldo; Bermúdez Coronel, Álvaro; Escobar Soto, Jhon J.; Naula, Wilson; Florencio, Arnaldo; Lourdes Valenzuela, María; Ramos Alfaro, Olman; Prenda Peña, Marcela

    2018-01-01

    This report describes the results of a supplementary comparison between SIM NMIs, which was carried out to evaluate the consistency of the measurements of calibration in high accuracy mass standards using the normalized error criteria (2 kg, 1 kg, 200 g, 50 g, 1 g and 200 mg). The supplementary comparison was carried out from April 2012 to July 2013. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  14. 26 CFR 1.402(g)-1 - Limitation on exclusion for elective deferrals.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... 1.402(g)-1 Section 1.402(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY.... § 1.402(g)-1 Limitation on exclusion for elective deferrals. (a) In general. The excess of an... income for the taxable year on account of section 402(a)(8) (before applying the limits of section 402(g...

  15. 26 CFR 1.402(g)-1 - Limitation on exclusion for elective deferrals.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... 1.402(g)-1 Section 1.402(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY.... § 1.402(g)-1 Limitation on exclusion for elective deferrals. (a) In general. The excess of an... income for the taxable year on account of section 402(a)(8) (before applying the limits of section 402(g...

  16. 26 CFR 1.402(g)-1 - Limitation on exclusion for elective deferrals.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    .... 1.402(g)-1 Section 1.402(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY.... § 1.402(g)-1 Limitation on exclusion for elective deferrals. (a) In general. The excess of an... income for the taxable year on account of section 402(a)(8) (before applying the limits of section 402(g...

  17. 26 CFR 1.642(g)-1 - Disallowance of double deductions; in general.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....642(g)-1 Section 1.642(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Estates, Trusts, and Beneficiaries § 1.642(g)-1..., after a statement is filed under section 642(g) with respect to a particular item or portion of an item...

  18. 26 CFR 1.642(g)-1 - Disallowance of double deductions; in general.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....642(g)-1 Section 1.642(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Estates, Trusts, and Beneficiaries § 1.642(g)-1..., after a statement is filed under section 642(g) with respect to a particular item or portion of an item...

  19. 26 CFR 1.642(g)-1 - Disallowance of double deductions; in general.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ....642(g)-1 Section 1.642(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Estates, Trusts, and Beneficiaries § 1.642(g)-1..., after a statement is filed under section 642(g) with respect to a particular item or portion of an item...

  20. 26 CFR 1.642(g)-1 - Disallowance of double deductions; in general.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ....642(g)-1 Section 1.642(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Estates, Trusts, and Beneficiaries § 1.642(g)-1..., after a statement is filed under section 642(g) with respect to a particular item or portion of an item...

  1. 26 CFR 1.642(g)-1 - Disallowance of double deductions; in general.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ....642(g)-1 Section 1.642(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Estates, Trusts, and Beneficiaries § 1.642(g)-1 Disallowance..., after a statement is filed under section 642(g) with respect to a particular item or portion of an item...

  2. 26 CFR 1.402(g)-1 - Limitation on exclusion for elective deferrals.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ....402(g)-1 Section 1.402(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY.... § 1.402(g)-1 Limitation on exclusion for elective deferrals. (a) In general. The excess of an... income for the taxable year on account of section 402(a)(8) (before applying the limits of section 402(g...

  3. 16 CFR Appendix G8 to Part 305 - Boilers (Electric)

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Boilers (Electric) G8 Appendix G8 to Part... LABELING RULEâ) Appendix G8 to Part 305—Boilers (Electric) Type Range of annual fuel utilization efficiencies (AFUEs) Low High Electric Boilers 100 100 [78 FR 8377, Feb. 6, 2013] ...

  4. TU-G-BRD-05: Results From Multi-Institutional Measurements with An Anthropomorphic Spine Phantom

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molineu, A; Hernandez, N; Alvarez, P

    Purpose: To analyze the results from an anthropomorphic spine phantom used for credentialing institutions for National Cancer Institute (NCI) sponsored clinical trial. Methods: An anthropomorphic phantom that contains left and right lungs, a heart, an esophagus, spinal cord, bony material and a PTV was sent to institutions wishing to be credentialed for NCI trials. The PTV holds 4 TLD and radiochromic film in the axial and sagittal planes. The heart holds one TLD. Institutions created IMRT plans to cover ≥90% of the PTV with 6 Gy and limit the cord dose to <0.35cc receiving 3.75 Gy and <1.2cc receiving 2.63more » Gy. They were instructed to treat the phantom as they would a patient, including making plan specific IMRT/SBRT QA measurements before treatment. The TLD results in the PTV were required to be within ±7% of the plan dose. A gamma calculation was performed using the film results and the submitted DICOM plan. ≥85% of the analyzed region was required to pass a 5%/3 mm criteria. Results: 176 institutions irradiated the spine phantom for a total of 255 results. The pass rate was 73% (187 irradiations) overall. 44 irradiations failed only the gamma criteria, 2 failed only the dose criteria and 22 failed both. The most used planning systems were Eclipse (116) and Pinnacle (52) and they had pass rates of 76% and 71%, respectively. The AAA algorithm had a pass rate of 77% while superposition type algorithms had a 71% pass rate. The average TLD measurement to institution calculation ratio was 0.99 (0.04 std dev.). The average percent pixels passing the gamma criteria for films was 89% (12% std dev.) Conclusion: Results show that this phantom is an important part of credentialing and that we have room for improvement in IMRT/SBRT spine treatments. This work was supported by PHS CA180803 and CA037422 awarded by NCI, DHHS.« less

  5. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100 Section 84.100 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES OCCUPATIONAL SAFETY AND HEALTH RESEARCH AND RELATED ACTIVITIES APPROVAL OF RESPIRATORY PROTECTIVE DEVICES Self-Contained Breathing Apparatus § 84.100 Man tests 1...

  6. Association of the plasminogen activator inhibitor-1 (PAI-1) Gene -675 4G/5G and -844 A/G promoter polymorphism with risk of keloid in a Chinese Han population.

    PubMed

    Wang, Yongjie; Long, Jianhong; Wang, Xiaoyan; Sun, Yang

    2014-10-28

    A keloid is pathological scar caused by aberrant response to skin injuries, characterized by excessive accumulation of histological extracellular matrix, and occurs in genetically susceptible individuals. Plasminogen activator inhibitor-1 (PAI-1) has been implicated in the pathogenesis of keloid. We investigated the association between PAI-1 polymorphisms and plasma PAI-1 level with keloid risk. A total of 242 Chinese keloid patients and 207 controls were enrolled in this study. Polymerase chain reaction-restriction technique was used to determine PAI-1 promoter polymorphism (-675 4G/5G and -844 A/G) distribution. Plasma PAI-1 levels were detected using enzyme-linked immunosorbent assay (ELISA). There was a statistically significant difference in the distribution of PAI-1 -675 4G/5G polymorphism between keloid patients and healthy controls. 4G/4G carriers were more likely to develop keloid. In contrast, the -844 A/G polymorphism distribution did not vary significantly between keloid patients and controls. The keloid patients group had a significantly higher plasma PAI-1 level than the control group. In the -675 4G/4G carrier population, the plasma PAI-1 levels were significant higher in keloid patients compared with controls. Our study provides evidence that PAI-1 promoter polymorphism -675 4G/5G and plasma PAI-1 level are associated with keloid risk. PAI-1 -675 4G/5G polymorphism may be an important hereditary factor responsible for keloid development in the Chinese Han population.

  7. A study of the possible association of plasminogen activator inhibitor type 1 4G/5G insertion/deletion polymorphism with susceptibility to schizophrenia and in its subtypes.

    PubMed

    Yenilmez, C; Ozdemir Koroglu, Z; Kurt, H; Yanas, M; Colak, E; Degirmenci, I; Gunes, H V

    2017-02-01

    Inhibition of the fibrinolytic system may occur at the level of plasminogen activation, mainly by PAI-1. Mental and physical stress caused to alterations of platelet function, and also decreased to fibrinolytic activity. Furthermore, stress-induced thrombosis regulation was proposed to be by PAI-1 in schizophrenia patients. In this study, the distribution of genotypes and frequency of alleles of the plasminogen activator inhibitor type 1 (PAI-1) gene 4G/5G polymorphism in different Turkish clinical schizophrenia subtypes was investigated for its role in schizophrenia development. The clinical schizophrenia subtypes include paranoid, catatonic, disorganized, undifferentiated and residual, as diagnosed according to the Diagnostic and Statistical Manual of Mental Disorders-Fourth Edition IV (DSM-IV). Samples of genomic DNA (250 total, including 150 schizophrenia patients and 100 healthy subjects) were analysed. PAI-1 4G/5G genotyping was performed by polymerase chain reaction-allele-specific amplification. PCR products were separated by 2% agarose gel electrophoresis and then visualized. The genotype distributions (P = 0·136) and allele frequencies (P = 0·721 for 4G, P = 0. 097 for 5G) were not significantly different between patients with schizophrenia and control subjects for the 4G/5G polymorphism. Similar results were also found for the genotype distributions (P = 0·640) and allele frequencies (P = 0·763 for 4G, P = 0·448 for 5G) in the clinical schizophrenia subtypes compared to the each other. We conclude that PAI-1 4G/5G polymorphism was not significantly associated with schizophrenia or its subtypes in the Turkish population. However, we recognize that with our sample sizes, we cannot exclude weak associations. © 2016 John Wiley & Sons Ltd.

  8. Relationship of plasminogen activator inhibitor 1 gene 4G/5G polymorphisms to hypertension in Korean women.

    PubMed

    Kim, Kyu-nam; Kim, Kwang-min; Kim, Bom-taeck; Joo, Nam-seok; Cho, Doo-yeoun; Lee, Duck-joo

    2012-04-01

    Hypertension (HTN) is a major determinant of various cardiovascular events. Plasma levels of plasminogen activator inhibitor 1 (PAI-1) modulate this risk. A deletion/insertion polymorphism within the PAI-1 loci (4G/4G, 4G/5G, 5G/5G) affects the expression of this gene. The present study investigated the association between PAI-1 loci polymorphisms and HTN in Korean women. Korean women (n = 1312) were enrolled in this study to evaluate the association between PAI-1 4G/5G gene polymorphisms and HTN as well as other metabolic risk factors. PAI-1 loci polymorphisms were investigated using polymerase chain reaction amplification and single-strand conformation polymorphism analysis. The three genotype groups differed with respect to systolic blood pressure (P = 0.043), and diastolic blood pressure (P = 0.009) but not with respect to age, body mass index, total cholesterol, low or high density lipoprotein cholesterol, triglycerides, or fasting blood glucose. Carriers of the PAI-1 4G allele had more hypertension significantly (PAI-1 4G/5G vs. PAI-1 5G/5G, P = 0.032; PAI-1 4G/4G vs. PAI-1 5G/5G, P = 0.034). When stratified according to PAI-1 4G/5G polymorphism, there was no significant difference in all metabolic parameters among PAI-1 genotype groups in patients with HTN as well as subjects with normal blood pressure. The estimated odds ratio of the 4G/4G genotype and 4G/5G for HTN was 1.7 (P = 0.005), and 1.6 (P = 0.015), respectively. These findings might indicate that PAI-1 loci polymorphisms independently contribute to HTN and that gene-environmental interaction may be not associated in Korean women.

  9. Association of the Plasminogen Activator Inhibitor-1 (PAI-1) Gene -675 4G/5G and -844 A/G Promoter Polymorphism with Risk of Keloid in a Chinese Han Population

    PubMed Central

    Wang, Yongjie; Long, Jianhong; Wang, Xiaoyan; Sun, Yang

    2014-01-01

    Background A keloid is pathological scar caused by aberrant response to skin injuries, characterized by excessive accumulation of histological extracellular matrix, and occurs in genetically susceptible individuals. Plasminogen activator inhibitor-1 (PAI-1) has been implicated in the pathogenesis of keloid. We investigated the association between PAI-1 polymorphisms and plasma PAI-1 level with keloid risk. Material/Methods A total of 242 Chinese keloid patients and 207 controls were enrolled in this study. Polymerase chain reaction-restriction technique was used to determine PAI-1 promoter polymorphism (-675 4G/5G and -844 A/G) distribution. Plasma PAI-1 levels were detected using enzyme-linked immunosorbent assay (ELISA). Results There was a statistically significant difference in the distribution of PAI-1 -675 4G/5G polymorphism between keloid patients and healthy controls. 4G/4G carriers were more likely to develop keloid. In contrast, the -844 A/G polymorphism distribution did not vary significantly between keloid patients and controls. The keloid patients group had a significantly higher plasma PAI-1 level than the control group. In the -675 4G/4G carrier population, the plasma PAI-1 levels were significant higher in keloid patients compared with controls. Conclusions Our study provides evidence that PAI-1 promoter polymorphism -675 4G/5G and plasma PAI-1 level are associated with keloid risk. PAI-1 -675 4G/5G polymorphism may be an important hereditary factor responsible for keloid development in the Chinese Han population. PMID:25350781

  10. Activation of G protein-coupled estrogen receptor 1 induces coronary artery relaxation via Epac/Rap1-mediated inhibition of RhoA/Rho kinase pathway in parallel with PKA.

    PubMed

    Yu, Xuan; Zhang, Qiao; Zhao, Yan; Schwarz, Benjamin J; Stallone, John N; Heaps, Cristine L; Han, Guichun

    2017-01-01

    Previously, we reported that cAMP/PKA signaling is involved in GPER-mediated coronary relaxation by activating MLCP via inhibition of RhoA pathway. In the current study, we tested the hypothesis that activation of GPER induces coronary artery relaxation via inhibition of RhoA/Rho kinase pathway by cAMP downstream targets, exchange proteins directly activated by cAMP (Epac) as well as PKA. Our results show that Epac inhibitors, brefeldin A (BFA, 50 μM), or ESI-09 (20 μM), or CE3F4 (100 μM), all partially inhibited porcine coronary artery relaxation response to the selective GPER agonist, G-1 (0.3-3 μM); while concurrent administration of BFA and PKI (5 μM), a PKA inhibitor, almost completely blocked the relaxation effect of G-1. The Epac specific agonist, 8-CPT-2Me-cAMP (007, 1-100 μM), induced a concentration-dependent relaxation response. Furthermore, the activity of Ras-related protein 1 (Rap1) was up regulated by G-1 (1 μM) treatment of porcine coronary artery smooth muscle cells (CASMCs). Phosphorylation of vasodilator-stimulated phosphoprotein (p-VASP) was elevated by G-1 (1 μM) treatment, but not by 007 (50 μM); and the effect of G-1 on p-VASP was blocked by PKI, but not by ESI-09, an Epac antagonist. RhoA activity was similarly down regulated by G-1 and 007, whereas ESI-09 restored most of the reduced RhoA activity by G-1 treatment. Furthermore, G-1 decreased PGF2α-induced p-MYPT1, which was partially reversed with either ESI-09 or PKI; whereas, concurrent administration of ESI-09 and PKI totally prevented the inhibitory effect of G-1. The inhibitory effects of G-1 on p- MLC levels in CASMCs were mostly restored by either ESI-09 or PKI. These results demonstrate that activation of GPER induces coronary artery relaxation via concurrent inhibition of RhoA/Rho kinase by Epac/Rap1 and PKA. GPER could be a potential drug target for preventing and treating cardiovascular diseases.

  11. 26 CFR 1.642(g)-2 - Deductions included.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 8 2014-04-01 2014-04-01 false Deductions included. 1.642(g)-2 Section 1.642(g... (CONTINUED) INCOME TAXES (CONTINUED) Estates, Trusts, and Beneficiaries § 1.642(g)-2 Deductions included. It...(g) is applicable be treated in the same way. One deduction or portion of a deduction may be allowed...

  12. 26 CFR 1.642(g)-2 - Deductions included.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 8 2013-04-01 2013-04-01 false Deductions included. 1.642(g)-2 Section 1.642(g... (CONTINUED) INCOME TAXES (CONTINUED) Estates, Trusts, and Beneficiaries § 1.642(g)-2 Deductions included. It...(g) is applicable be treated in the same way. One deduction or portion of a deduction may be allowed...

  13. 26 CFR 1.642(g)-2 - Deductions included.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 8 2011-04-01 2011-04-01 false Deductions included. 1.642(g)-2 Section 1.642(g... (CONTINUED) INCOME TAXES (CONTINUED) Estates, Trusts, and Beneficiaries § 1.642(g)-2 Deductions included. It...(g) is applicable be treated in the same way. One deduction or portion of a deduction may be allowed...

  14. 26 CFR 1.642(g)-2 - Deductions included.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 8 2012-04-01 2012-04-01 false Deductions included. 1.642(g)-2 Section 1.642(g... (CONTINUED) INCOME TAXES (CONTINUED) Estates, Trusts, and Beneficiaries § 1.642(g)-2 Deductions included. It...(g) is applicable be treated in the same way. One deduction or portion of a deduction may be allowed...

  15. 26 CFR 1.642(g)-2 - Deductions included.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 8 2010-04-01 2010-04-01 false Deductions included. 1.642(g)-2 Section 1.642(g... (CONTINUED) INCOME TAXES Estates, Trusts, and Beneficiaries § 1.642(g)-2 Deductions included. It is not required that the total deductions, or the total amount of any deduction, to which section 642(g) is...

  16. Polymorphisms of endothelin 1 (G5665T and T-1370G) and endothelin receptor type A (C+70G and G-231A) in Graves' disease.

    PubMed

    Aydın, A Fatih; Develi-İş, Seval; Doğru-Abbasoğlu, Semra; Vural, Pervin; Ozderya, Ayşenur; Karadağ, Berrin; Uysal, Müjdat

    2014-01-01

    Endothelin 1 (EDN1) is a strong angiogenic and mitogenic factor, playing a key role in hypervascularization, thyroid follicle cell hyperplasia, and lymphocyte infiltration in the thyroid gland of patients with Graves' disease (GD). EDN1 induces angiogenesis and mitogenesis via endothelin receptor type A (EDNRA). This study examined the possible association of EDN1 (G5665T and T-1370G) and EDNRA (C+70G and G-231A) single nucleotide polymorphisms (SNPs) with the occurrence of GD, and evaluates the relationship between genotypes and clinical/laboratory manifestations of GD. We analyzed genotype and allele distributions of EDN1 and EDNRA polymorphisms in 165 patients with GD and 181 healthy controls by real-time PCR combined with melting curve analysis. No significant associations between GD and variant alleles of the studied polymorphisms were observed. However, the anti-thyroid peroxidase (anti-TPO) and anti-thyroglobulin (anti-TG) levels in EDN1 G5665T GG genotype were higher than those in T allele carriers (GT+TT) (p=0.001 and p=0.026, respectively). In addition, anti-TPO levels in EDN1 T-1370G wild-type homozygous patients were found to be higher than in mutant gene carrying patients (GT+GG) (p=0.006). The presence of EDNRA+70G allele was associated with 3.37-fold increased risk for development of ophthalmopathy in GD patients (p=0.009). Although there were no associations between EDN1 (G5665T and T-1370G) and EDNRA (C+70G and G-231A) SNPs and susceptibility to GD, EDN1 G5665T and T-1370G polymorphisms were related to alterations of autoantibody production and EDNRA C+70G polymorphism is related with increased risk for ophthalmopathy in GD patients. Copyright © 2013 Elsevier B.V. All rights reserved.

  17. SU-E-T-101: Determination and Comparison of Correction Factors Obtained for TLDs in Small Field Lung Heterogenous Phantom Using Acuros XB and EGSnrc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soh, R; Lee, J; Harianto, F

    Purpose: To determine and compare the correction factors obtained for TLDs in 2 × 2cm{sup 2} small field in lung heterogenous phantom using Acuros XB (AXB) and EGSnrc. Methods: This study will simulate the correction factors due to the perturbation of TLD-100 chips (Harshaw/Thermoscientific, 3 × 3 × 0.9mm{sup 3}, 2.64g/cm{sup 3}) in small field lung medium for Stereotactic Body Radiation Therapy (SBRT). A physical lung phantom was simulated by a 14cm thick composite cork phantom (0.27g/cm{sup 3}, HU:-743 ± 11) sandwiched between 4cm thick Plastic Water (CIRS,Norfolk). Composite cork has been shown to be a good lung substitute materialmore » for dosimetric studies. 6MV photon beam from Varian Clinac iX (Varian Medical Systems, Palo Alto, CA) with field size 2 × 2cm{sup 2} was simulated. Depth dose profiles were obtained from the Eclipse treatment planning system Acuros XB (AXB) and independently from DOSxyznrc, EGSnrc. Correction factors was calculated by the ratio of unperturbed to perturbed dose. Since AXB has limitations in simulating actual material compositions, EGSnrc will also simulate the AXB-based material composition for comparison to the actual lung phantom. Results: TLD-100, with its finite size and relatively high density, causes significant perturbation in 2 × 2cm{sup 2} small field in a low lung density phantom. Correction factors calculated by both EGSnrc and AXB was found to be as low as 0.9. It is expected that the correction factor obtained by EGSnrc wlll be more accurate as it is able to simulate the actual phantom material compositions. AXB have a limited material library, therefore it only approximates the composition of TLD, Composite cork and Plastic water, contributing to uncertainties in TLD correction factors. Conclusion: It is expected that the correction factors obtained by EGSnrc will be more accurate. Studies will be done to investigate the correction factors for higher energies where perturbation may be more pronounced.« less

  18. Extra dose due to extravehicular activity during the NASA4 mission measured by an on-board TLD system.

    PubMed

    Deme, S; Apathy, I; Hejja, I; Lang, E; Feher, I

    1999-01-01

    A microprocessor-controlled on-board TLD system, 'Pille'96', was used during the NASA4 (1997) mission to monitor the cosmic radiation dose inside the Mir Space Station and to measure the extra dose to two astronauts in the course of their extravehicular activity (EVA). For the EVA dose measurements, CaSO4:Dy bulb dosemeters were located in specially designed pockets of the ORLAN spacesuits. During an EVA lasting 6 h, the dose ratio inside and outside Mir was measured. During the EVA, Mir crossed the South Atlantic Anomaly (SAA) three times. Taking into account the influence of these three crossings the mean EVA/internal dose rate ratio was 3.2. Internal dose mapping using CaSO4:Dy dosemeters gave mean dose rates ranging from 9.3 to 18.3 microGy h-1 at locations where the shielding effect was not the same. Evaluation results of the high temperature region of LiF dosemeters are given to estimate the mean LET.

  19. A novel photo-grafting of acrylamide onto carboxymethyl starch. 1. Utilization of CMS-g-PAAm in easy care finishing of cotton fabrics.

    PubMed

    El-Sheikh, Manal A

    2016-11-05

    The photosensitized grafting of vinyl monomers onto a range of polymeric substrates has been the subject of particular interest in the recent past. Carboxymethyl starch (CMS)-poly acrylamide (PAAm) graft copolymer (CMS-g-PAAm) with high graft yield was successfully prepared by grafting of acrylamide onto CMS using UV irradiation in the presence of the water soluble 4-(trimethyl ammoniummethyl) benzophenone chloride photoinitiator. CMS-g-PAAm with nitrogen content of 8.3% and grafting efficiency up to 98.9% was obtained using 100% AAm, a material: liquor ratio of 1:14 and 1% photinitiator at 30°C for 1h of UV irradiation. The synthesis of CMS-g-PAAm was confirmed by FTIR and Nitrogen content (%). Surface morphology of CMS and surface morphological changes of CMS after grafting with AAm were studied using SEM. Thermal properties of both CMS and CMS-g-PAAm were studied using TGA and DSC. To impart easy care finishing to cotton fabrics, aqueous formulations of: CMS-g-PAAm, dimethylol dihydroxy ethylene urea (DMDHEU), CMS-g-PAAm-DMDHEU mixture or methylolated CMS-g-PAAm were used. Cotton fabrics were padded in these formulations, squeezed to a wet pick up 100%, dried at 100°C for 5min, cured at 150°C for 5min, washed at 50°C for 10min and air-dried. CRA (crease recovery angle) of untreated fabrics and fabrics finished with a mixture of 2% CMS-g-PAAm and 10% DMDHEU or methylolated CMS-g-PAAm (10% formaldehyde) were: 136°, 190°, 288° respectively. Increasing the number of washing cycles up to five cycles results in an insignificant decrease in the CRA and a significant decrease in RF (releasable formaldehyde) of finished fabric samples. The morphologies of the finished and unfinished cotton fabrics were performed by SEM. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. 26 CFR 1.56(g)-0 - Table of Contents.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 1 2011-04-01 2009-04-01 true Table of Contents. 1.56(g)-0 Section 1.56(g)-0... Applicable to Taxable Years Beginning in 1969 and Ending in 1970 § 1.56(g)-0 Table of Contents. This section lists the paragraphs contained in § 1.56(g)-1. § 1.56(g)-1Adjusted current earnings. (a) Adjustment for...

  1. 26 CFR 1.56(g)-0 - Table of Contents.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 1 2013-04-01 2013-04-01 false Table of Contents. 1.56(g)-0 Section 1.56(g)-0... Applicable to Taxable Years Beginning in 1969 and Ending in 1970 § 1.56(g)-0 Table of Contents. This section lists the paragraphs contained in § 1.56(g)-1. § 1.56(g)-1Adjusted current earnings. (a) Adjustment for...

  2. 26 CFR 1.56(g)-0 - Table of Contents.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 1 2012-04-01 2012-04-01 false Table of Contents. 1.56(g)-0 Section 1.56(g)-0... Applicable to Taxable Years Beginning in 1969 and Ending in 1970 § 1.56(g)-0 Table of Contents. This section lists the paragraphs contained in § 1.56(g)-1. § 1.56(g)-1Adjusted current earnings. (a) Adjustment for...

  3. 26 CFR 1.56(g)-0 - Table of Contents.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 1 2014-04-01 2013-04-01 true Table of Contents. 1.56(g)-0 Section 1.56(g)-0... Applicable to Taxable Years Beginning in 1969 and Ending in 1970 § 1.56(g)-0 Table of Contents. This section lists the paragraphs contained in § 1.56(g)-1. § 1.56(g)-1Adjusted current earnings. (a) Adjustment for...

  4. Relationship between post-SARS osteonecrosis and PAI-1 4G/5G gene polymorphisms.

    PubMed

    Sun, Wei; Li, Zirong; Shi, Zhengcai; Wang, Bailiang; Gao, Fuqiang; Yang, Yurun; Guo, Wanshou

    2014-05-01

    To explore the correlation between post-severe acute respiratory symptom (SARS) patients with osteonecrosis, investigate the etiology of post-SARS osteonecrosis and select the sensitive molecular symbols for early diagnosis and distinguish the high-risk population. The studied subjects were divided into two groups. Sixty-two post-SARS patients with osteonecrosis were one group, and 52 age- and sex-matched healthy people were as normal controlled group. Empty stomach blood samples from cubital veins were collected from both groups. Plasminogen activator inhibitor (PAI) by means of enzyme-linked immunosorbent assay and PAI-1 4G/5G polymorphism was detected by polymerase chain reaction and solid phase oligonucleotide assay. The blood agents of post-SARS patients changed obviously with 15.64 ± 13.85 U/ml while the control group 7.96 ± 4.27 U/ml; 4G/4G genotype for the PAI-1 polymorphism detected in post-SARS group was more than that of the control group, but had no statistical significance. The plasma PAI activity was related to homozygote 4G/4G genotype. This reveals that homozygote 4G/4G genotype may be a susceptible gene mark to Chinese osteonecrosis patients. Plasminogen activator inhibitor-1 is sensitive blood symbol for screening high-risk susceptible population; 4G/4G PAI-1 genotype may be an etiological factor in osteonecrosis.

  5. High resolution spectral analysis of oxygen. I. Isotopically invariant Dunham fit for the X(3)Σ(g)(-), a(1)Δ(g), b(1)Σ(g)(+) states.

    PubMed

    Yu, Shanshan; Miller, Charles E; Drouin, Brian J; Müller, Holger S P

    2012-07-14

    We have developed a simultaneous global fit to the MW, THz, infrared, visible, and UV transitions of all six oxygen isotopologues, (16)O(16)O, (16)O(17)O, (16)O(18)O, (17)O(17)O, (17)O(18)O, (18)O(18)O, with the objective of predicting all transitions below the O((3)P) + O((3)P) dissociation threshold as well as the B(3)Σ(u) (-) state from O((3)P)+O((1)D) within state-of-the-art experimental uncertainty. Here, we report an isotopically invariant Dunham fit for the lowest three electronic states, X(3)Σ(g)(-), a(1)Δ(g), and b(1)Σ(g)(+). Experimental transition frequencies involving these three states of all six O(2) isotopologues were critically reviewed and incorporated into the analysis. For the (16)O(16)O isotopologue, experimental data sample vibrational states v = 0-31 for X(3)Σ(g)(-), v = 0-10 for a(1)Δ(g), and v = 0-12 for b(1)Σ(g)(+). To the best of our knowledge, this is the first analysis that simultaneously fits spectra from all six O(2) isotopologues.

  6. 26 CFR 1.422-4 - $100,000 limitation for incentive stock options.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false $100,000 limitation for incentive stock options... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES Certain Stock Options § 1.422-4 $100,000 limitation for incentive stock options. (a) $100,000 per year limitation—(1) General rule. An option that otherwise...

  7. Cilioretinal artery: Vasculogenesis might be promoted by plasminogen activator inhibitor-1 5G allele.

    PubMed

    Yilmaz, Sarenur; Ardagil, Aylin; Akalin, Ibrahim; Altinel, Meltem Guzin; Dag, Yasar; Kurum, Esra; Koyun, Efe; Ari Yaylali, Sevil; Bayramlar, Huseyin

    2017-01-01

    Cilioretinal arteries (CAs) represent enlargements of microscopic and early established collaterals formed via vasculogenesis between choroidal and retinal circulations. We aimed to investigate whether genetic tendency to thrombosis due to well-known gene polymorphisms may induce CA vasculogenesis in embryonic life. We assessed plasminogen activator inhibitor-1 (PAI-1) 4G/5G, methylenetetrahydrofolatereductase (MTHFR), FACTOR V LEIDEN and PROTHROMBIN gene polymorphisms on 130 patients [82/48 females/males; Median age: 57 (18-84) with visible CAs and 100 (64/36: female/male; Median age: 55 (19-90)] without visible CAs. Using multiple logistic regression models, we found PAI-1 4G/5G; MTHFR (C677T and A1298C) polymorphisms to have significant effects on the probability of visible CAs, that having at least one 5G allele would increase the odds of having visible cilioretinal artery by 98.4% [Odds ratio: 1984 (95% CI: 1.320-3.000, p = 0.001)], and having at least one MTHFR C677T or A1298C allele would decrease the odds of having visible CAs by approximately 38% (OR = 0.618, 95% CI: 0.394-0.961, p = 0.035) or 44% (OR = 0.558, 95% CI: 0.354-0.871, p = 0.011), respectively. This is the first study to test the existence of significant association between presence of enlarged and visible CAs and genetic factors predisposing to thrombosis, according to the literature. Here we suggest that not only the lack of genetic predisposition to thrombosis by MTHFR gene polymorphisms, but also the PAI-1 5G allele might promote vasculogenesis of CAs.

  8. 41 CFR 109-1.100-50 - Scope of subpart.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 41 Public Contracts and Property Management 3 2012-01-01 2012-01-01 false Scope of subpart. 109-1... Regulations System (Continued) DEPARTMENT OF ENERGY PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 109-1.100-50 Scope of subpart. This subpart sets forth the Department of Energy (DOE...

  9. 41 CFR 109-1.100-50 - Scope of subpart.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 3 2013-07-01 2013-07-01 false Scope of subpart. 109-1... Regulations System (Continued) DEPARTMENT OF ENERGY PROPERTY MANAGEMENT REGULATIONS GENERAL 1-INTRODUCTION 1.1-Regulation System § 109-1.100-50 Scope of subpart. This subpart sets forth the Department of Energy (DOE...

  10. 16 CFR Appendix G2 to Part 305 - Furnaces- Electric

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Furnaces- Electric G2 Appendix G2 to Part... LABELING RULEâ) Appendix G2 to Part 305—Furnaces— Electric Furnace type Range of annual fuel utilization efficiencies (AFUEs) Low High Electric Furnaces—All Capacities 100.0 100.0 [78 FR 8377, Feb. 6, 2013] ...

  11. Interplay between Trx-1 and S100P promotes colorectal cancer cell epithelial-mesenchymal transition by up-regulating S100A4 through AKT activation.

    PubMed

    Zuo, Zhigui; Zhang, Peili; Lin, Feiyan; Shang, Wenjing; Bi, Ruichun; Lu, Fengying; Wu, Jianbo; Jiang, Lei

    2018-04-01

    We previously reported a novel positive feedback loop between thioredoxin-1 (Trx-1) and S100P, which promotes the invasion and metastasis of colorectal cancer (CRC). However, the underlying molecular mechanisms remain poorly understood. In this study, we examined the roles of Trx-1 and S100P in CRC epithelial-to-mesenchymal transition (EMT) and their underlying mechanisms. We observed that knockdown of Trx-1 or S100P in SW620 cells inhibited EMT, whereas overexpression of Trx-1 or S100P in SW480 cells promoted EMT. Importantly, S100A4 and the phosphorylation of AKT were identified as potential downstream targets of Trx-1 and S100P in CRC cells. Silencing S100A4 or inhibition of AKT phosphorylation eliminated S100P- or Trx-1-mediated CRC cell EMT, migration and invasion. Moreover, inhibition of AKT activity reversed S100P- or Trx-1-induced S100A4 expression. The expression of S100A4 was higher in human CRC tissues compared with their normal counterpart tissues and was significantly correlated with lymph node metastasis and poor survival. The overexpression of S100A4 protein was also positively correlated with S100P or Trx-1 protein overexpression in our cohort of CRC tissues. In addition, overexpression of S100P reversed the Trx-1 knockdown-induced inhibition of S100A4 expression, EMT and migration and invasion in SW620 cells. The data suggest that interplay between Trx-1 and S100P promoted CRC EMT as well as migration and invasion by up-regulating S100A4 through AKT activation, thus providing further potential therapeutic targets for suppressing the EMT in metastatic CRC. © 2018 The Authors. Journal of Cellular and Molecular Medicine published by John Wiley & Sons Ltd and Foundation for Cellular and Molecular Medicine.

  12. Isorhapontigenin (ISO) inhibited cell transformation by inducing G0/G1 phase arrest via increasing MKP-1 mRNA Stability.

    PubMed

    Gao, Guangxun; Chen, Liang; Li, Jingxia; Zhang, Dongyun; Fang, Yong; Huang, Haishan; Chen, Xiequn; Huang, Chuanshu

    2014-05-15

    The cancer chemopreventive property of Chinese herb new isolate isorhapontigenin (ISO) and mechanisms underlying its activity have never been explored. Here we demonstrated that ISO treatment with various concentrations for 3 weeks could dramatically inhibit TPA/EGF-induced cell transformation of Cl41 cells in Soft Agar assay, whereas co-incubation of cells with ISO at the same concentrations could elicit G0/G1 cell-cycle arrest without redundant cytotoxic effects on non-transformed cells. Further studies showed that ISO treatment resulted in cyclin D1 downregulation in dose- and time-dependent manner. Our results indicated that ISO regulated cyclin D1 at transcription level via targeting JNK/C-Jun/AP-1 activation. Moreover, we found that ISO-inhibited JNK/C-Jun/AP-1 activation was mediated by both upregulation of MKP-1 expression through increasing its mRNA stability and deactivating MKK7. Most importantly, MKP-1 knockdown could attenuate ISO-mediated suppression of JNK/C-Jun activation and cyclin D1 expression, as well as G0/G1 cell cycle arrest and cell transformation inhibition, while ectopic expression of FLAG-cyclin D1 T286A mutant also reversed ISO-induced G0/G1 cell-cycle arrest and inhibition of cell transformation. Our results demonstrated that ISO is a promising chemopreventive agent via upregulating mkp-1 mRNA stability, which is distinct from its cancer therapeutic effect with downregulation of XIAP and cyclin D1 expression.

  13. Birth of Archaeal Cells: Molecular Phylogenetic Analyses of G1P Dehydrogenase, G3P Dehydrogenases, and Glycerol Kinase Suggest Derived Features of Archaeal Membranes Having G1P Polar Lipids

    PubMed Central

    2016-01-01

    Bacteria and Eukarya have cell membranes with sn-glycerol-3-phosphate (G3P), whereas archaeal membranes contain sn-glycerol-1-phosphate (G1P). Determining the time at which cells with either G3P-lipid membranes or G1P-lipid membranes appeared is important for understanding the early evolution of terrestrial life. To clarify this issue, we reconstructed molecular phylogenetic trees of G1PDH (G1P dehydrogenase; EgsA/AraM) which is responsible for G1P synthesis and G3PDHs (G3P dehydrogenase; GpsA and GlpA/GlpD) and glycerol kinase (GlpK) which is responsible for G3P synthesis. Together with the distribution of these protein-encoding genes among archaeal and bacterial groups, our phylogenetic analyses suggested that GlpA/GlpD in the Commonote (the last universal common ancestor of all extant life with a cellular form, Commonote commonote) acquired EgsA (G1PDH) from the archaeal common ancestor (Commonote archaea) and acquired GpsA and GlpK from a bacterial common ancestor (Commonote bacteria). In our scenario based on this study, the Commonote probably possessed a G3P-lipid membrane synthesized enzymatically, after which the archaeal lineage acquired G1PDH followed by the replacement of a G3P-lipid membrane with a G1P-lipid membrane. PMID:27774041

  14. The G protein Gi1 exhibits basal coupling but not preassembly with G protein-coupled receptors.

    PubMed

    Bondar, Alexey; Lazar, Josef

    2017-06-09

    The G i/o protein family transduces signals from a diverse group of G protein-coupled receptors (GPCRs). The observed specificity of G i/o -GPCR coupling and the high rate of G i/o signal transduction have been hypothesized to be enabled by the existence of stable associates between G i/o proteins and their cognate GPCRs in the inactive state (G i/o -GPCR preassembly). To test this hypothesis, we applied the recently developed technique of two-photon polarization microscopy (2PPM) to Gα i1 subunits labeled with fluorescent proteins and four GPCRs: the α 2A -adrenergic receptor, GABA B , cannabinoid receptor type 1 (CB 1 R), and dopamine receptor type 2. Our experiments with non-dissociating mutants of fluorescently labeled Gα i1 subunits (exhibiting impaired dissociation from activated GPCRs) showed that 2PPM is capable of detecting GPCR-G protein interactions. 2PPM experiments with non-mutated fluorescently labeled Gα i1 subunits and α 2A -adrenergic receptor, GABA B , or dopamine receptor type 2 receptors did not reveal any interaction between the G i1 protein and the non-stimulated GPCRs. In contrast, non-stimulated CB 1 R exhibited an interaction with the G i1 protein. Further experiments revealed that this interaction is caused solely by CB 1 R basal activity; no preassembly between CB 1 R and the G i1 protein could be observed. Our results demonstrate that four diverse GPCRs do not preassemble with non-active G i1 However, we also show that basal GPCR activity allows interactions between non-stimulated GPCRs and G i1 (basal coupling). These findings suggest that G i1 interacts only with active GPCRs and that the well known high speed of GPCR signal transduction does not require preassembly between G proteins and GPCRs. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  15. Association between plasminogen activator inhibitor-1 -675 4G/5G polymorphism and sepsis: a meta-analysis.

    PubMed

    Li, Li; Nie, Wei; Zhou, Hongfeng; Yuan, Weifeng; Li, Weifeng; Huang, Wenjie

    2013-01-01

    Several studies have evaluated the association between plasminogen activator inhibitor-1 (PAI-1) -675 4G/5G polymorphism and sepsis in different populations. However, the available results are conflicting. A search of Pubmed and EMBASE databases was performed to identify relevant studies for inclusion in the meta-analysis. Odds ratios (ORs) and corresponding 95% confidence intervals (CIs) were determined using a random-effects model. Twelve case-control studies and three cohort studies were included. Overall, a significant association between 4G/5G polymorphism and sepsis risk was observed for 4G/4G vs. 4G/5G +5G/5G (OR = 1.30, 95% CI 1.08-1.56, P = 0.006). In addition, there was a significant association between PAI-1 4G/5G polymorphism and sepsis-related mortality (OR = 1.72, 95% CI 1.27-2.33, P = 0.0005). In subgroup analyses, increased sepsis risk and mortality risk were found in Caucasians and in patients with sepsis. This meta-analysis suggested that the PAI-1 -675 4G/5G polymorphism was a risk factor for sepsis and sepsis mortality.

  16. Comparison of thermoluminescence response of different sized Ge-doped flat fibers as a dosimeter

    NASA Astrophysics Data System (ADS)

    Begum, Mahfuza; Mizanur Rahman, A. K. M.; Abdul-Rashid, H. A.; Yusoff, Z.; Mat-Sharif, K. A.; Zulkifli, M. I.; Muhamad-Yasin, S. Z.; Ung, N. M.; Kadir, A. B. A.; Amin, Y. M.; Bradley, D. A.

    2015-11-01

    Prime dosimetric properties, including dose-response, linearity with dose, energy response, fading and threshold doses were investigated for three different dimension Ge-doped flat fibers. The results of measurement were also compared with two of the more commonly used standard TLD media, TLD-100 (LiF:Mg,Ti-7.5%6LiF) and TLD-700 (7LiF:Mg,Ti-99.9%7LiF) chips. The flat cross-section samples (60×180) μm2, (100×350) μm2 and (200×750) μm2 were fabricated using the Modified Chemical Vapor Deposition (MCVD) process and pulled from the same "preform." In the study, all flat fiber samples provided good linear dose-response for the photon and electron beams generated using a medical linear accelerator (LINAC), for doses in the range 0.5-8 Gy. Among the samples, the smallest dimension flat fiber provided the best response, with a sensitivity of some 61% and 54%, respectively of that of the TLD-100 and TLD-700 chips. The energy responses of the samples were studied for various photon (6 MV, 10 MV) and electron (6 MeV, 9 MeV) beam energies. TL fading of around 20% was observed over a period of thirty (30) days. These favorable TL characteristics point towards promising development of Ge-doped flat fibers for use in radiotherapy dosimetry.

  17. Digital geologic map of the Coeur d'Alene 1:100,000 quadrangle, Idaho and Montana

    USGS Publications Warehouse

    digital compilation by Munts, Steven R.

    2000-01-01

    Between 1961 and 1969, Alan Griggs and others conducted fieldwork to prepare a geologic map of the Spokane 1:250,000 map (Griggs, 1973). Their field observations were posted on paper copies of 15-minute quadrangle maps. In 1999, the USGS contracted with the Idaho Geological Survey to prepare a digital version of the Coeur d’Alene 1:100,000 quadrangle. To facilitate this work, the USGS obtained the field maps prepared by Griggs and others from the USGS Field Records Library in Denver, Colorado. The Idaho Geological Survey (IGS) digitized these maps and used them in their mapping program. The mapping focused on field checks to resolve problems in poorly known areas and in areas of disagreement between adjoining maps. The IGS is currently in the process of preparing a final digital spatial database for the Coeur d’Alene 1:100,000 quadrangle. However, there was immediate need for a digital version of the geologic map of the Coeur d’Alene 1:100,000 quadrangle and the data from the field sheets along with several other sources were assembled to produce this interim product. This interim product is the digital geologic map of the Coeur d’Alene 1:100,000 quadrangle, Idaho and Montana. It was compiled from the preliminary digital files prepared by the Idaho Geological, and supplemented by data from Griggs (1973) and from digital databases by Bookstrom and others (1999) and Derkey and others (1996). The resulting digital geologic map (GIS) database can be queried in many ways to produce a variety of geologic maps. Digital base map data files (topography, roads, towns, rivers and lakes, etc.) are not included: they may be obtained from a variety of commercial and government sources. This database is not meant to be used or displayed at any scale larger than 1:100,000 (e.g., 1:62,500 or 1:24,000). The digital geologic map graphics (of00-135_map.pdf) that are provided are representations of the digital database. The map area is located in north Idaho. This open

  18. Investigation of Plasminogen Activator Inhibitor-1 (PAI-1) 4G/5G promoter polymorphism in Indian venous thrombosis patients: A case-control study.

    PubMed

    Prabhudesai, Aniket; Shetty, Shrimati; Ghosh, Kanjaksha; Kulkarni, Bipin

    2017-09-01

    The role of PAI-1 4G/5G polymorphism in venous thrombosis has been contradictory. PAI-1 4G/4G genotype is associated with elevated levels of PAI-1 resulting in a hypofibrinolytic state and a higher thrombotic risk. In this study, the distribution of genotypes and frequency of alleles of the 4G/5G polymorphism of PAI-1 gene in Indian patients with different types of venous thrombosis was investigated for its role in development of thrombosis. A total of 87 portal vein thrombosis (PVT), 71 Budd-Chiari syndrome (BCS), 156 cerebral vein thrombosis (CVT), and 163 deep vein thrombosis (DVT) patients were studied alongside 251 healthy controls for the PAI-1 4G/5G polymorphism by allele-specific PCR. Frequency of 4G/4G genotype was higher in all groups in comparison with controls. 4G/4G was associated with PVT risk (OR=2.51, 95% CI=1.29-4.96, P=.0075), BCS risk (OR=5.98, 95% CI=2.68-13.42, P<.0001), and DVT risk (OR=1.75, 95% CI=0.98-3.02, P=.0225). This is the first case-control study from India establishing PAI-1 4G/4G as a strong risk factor for abdominal thrombosis (PVT and BCS). Statistically significant association was not found between 4G/4G genotype and CVT risk. PAI-1 4G/4G is a strong risk factor for venous thrombosis in Indian patients and should be included in laboratory testing panel of thrombophilia. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  19. Evidence that the granulocyte colony-stimulating factor (G-CSF) receptor plays a role in the pharmacokinetics of G-CSF and PegG-CSF using a G-CSF-R KO model.

    PubMed

    Kotto-Kome, Anne C; Fox, Samuel E; Lu, Wenge; Yang, Bing-Bing; Christensen, Robert D; Calhoun, Darlene A

    2004-07-01

    The covalent attachment of polyethylene glycol to filgrastim results in a new molecule pegfilgrastim, which has a significantly longer half-life than filgrastim. It is likely that the clearance of both filgrastim and pegfilgrastim involves granulocyte colony simulating factor (G-CSF) receptor binding, but the pharmacokinetics of these drugs have not been compared in mice with and without a functional G-CSF receptor. We sought to clarify the role of receptor-mediated clearance of filgrastim and pegfilgrastim using wild-type (WT) mice or mice with a non-functional G-CSF-R (knockout, KO). We administered single doses of filgrastim or pegfilgrastim (10 or 100 microg kg(-1)) intravenously to WT and KO mice. Plasma levels of protein were measured by enzyme-linked immunosorbent assay (ELISA) at preset time points, and AUC, MRT, CL, V(d), and T(1/2) were calculated. When compared with WT mice, the G-CSF-R KO mice had significantly greater AUC, longer MRT, longer T(1/2), and lower clearance. This was the case whether animals received 10 or 100 microg kg(-1) and whether they received filgrastim or pegfilgrastim. The volume of protein distribution was identical among WT and KO mice. However, the V(d) was larger after pegfilgrastim dosing than after filgrastim dosing. In both WT and KO mice, increasing the dose of figrastim or pegfilgrastim resulted in a proportional increase in the AUC. A functional G-CSF-R is an important mechanism in the plasma clearance of both filgrastim and pegfilgrastim.

  20. G protein-coupled estrogen receptor 1 agonist G-1 induces cell cycle arrest in the mitotic phase, leading to apoptosis in endometriosis.

    PubMed

    Mori, Taisuke; Ito, Fumitake; Matsushima, Hiroshi; Takaoka, Osamu; Tanaka, Yukiko; Koshiba, Akemi; Kusuki, Izumi; Kitawaki, Jo

    2015-05-01

    To demonstrate the effects of the selective G protein-coupled estrogen receptor 1 (GPER) agonist G-1 in human ovarian endometriotic stromal cells (ESCs). Experimental in vitro study. University hospital. A total of 33 patients with ovarian endometrioma. Endometriotic stromal cells from ovarian chocolate cysts were treated with the GPER agonist G-1. The primary outcomes were cell proliferation, measured using the WST-8 assay; cell cycle, as analyzed using flow cytometry, fluorescent immunocytochemistry, and cytotoxicity; caspase activity, as measured by fluorescent and luminescent enzyme assays; and protein expression levels, as determined by Western blot analysis. G-1 suppressed ESC proliferation in a concentration-dependent manner. The inhibitory effect was not blocked when GPER signaling pathways, including the GPER itself, were inhibited. G-1 induced cell cycle arrest and accumulation in the sub-G1 phase in ESCs. Immunofluorescence analysis demonstrated that G-1 interrupted microtubule assembly at the mitotic phase. G-1 also induced caspase-3-dependent apoptosis without significant cytotoxicity. G-1 suppressed proliferation and induced apoptosis in ESCs, suggesting the potential use of this compound as a therapeutic drug for the treatment of endometriosis. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  1. Reduced carriership of 4G allele of plasminogen activator inhibitor-1 4G/5G polymorphism in very young survivors of myocardial infarction.

    PubMed

    Rallidis, Loukianos S; Gialeraki, Argyri; Merkouri, Efrosyni; Liakos, George; Dagres, Nikolaos; Sionis, Dimitrios; Travlou, Anthi; Lekakis, John; Kremastinos, Dimitrios T

    2010-05-01

    There are limited and controversial data regarding the impact of 4G/5G polymorphism of the plasminogen activator inhibitor-1 (PAI-1) gene in the pathogenesis of premature myocardial infarction (MI). We explored whether 4G/5G polymorphism of the PAI-1 gene is associated with the development of MI G/5G polymorphism of PAI-1 was tested with polymerase chain reaction and reverse hybridization. 4G allele carriers (4G/4G and 4G/5G genotypes) of PAI-1 were less frequent in patients than in controls (69.6 vs. 83.6%, P = 0.007). 4G carriership of the polymorphism of PAI-1 was associated with lower risk for acute MI (odds ratio 0.45, 95% confidence interval 0.23-0.88, P = 0.02) after adjusting for major cardiovascular risk factors. Patients possessing the 4G allele had higher PAI-1 plasma levels (32.2 +/- 25 vs. 22.2 +/- 11.3 ng/ml, P = 0.006) but lower lipoprotein(a) levels (10.1 [2.1-29.9] vs. 15.3 [8.2-57.1] mg/dl, P = 0.03) compared to 5G/5G homozygotes. Our data indicate that the 4G allele of the PAI-1 4G/5G polymorphism is less frequent among survivors of MI at very young age compared with matched controls.

  2. Association between Plasminogen Activator Inhibitor-1 -675 4G/5G Polymorphism and Sepsis: A Meta-Analysis

    PubMed Central

    Yuan, Weifeng; Li, Weifeng; Huang, Wenjie

    2013-01-01

    Background Several studies have evaluated the association between plasminogen activator inhibitor-1 (PAI-1) -675 4G/5G polymorphism and sepsis in different populations. However, the available results are conflicting. Methods A search of Pubmed and EMBASE databases was performed to identify relevant studies for inclusion in the meta-analysis. Odds ratios (ORs) and corresponding 95% confidence intervals (CIs) were determined using a random-effects model. Results Twelve case-control studies and three cohort studies were included. Overall, a significant association between 4G/5G polymorphism and sepsis risk was observed for 4G/4G vs. 4G/5G +5G/5G (OR = 1.30, 95% CI 1.08–1.56, P = 0.006). In addition, there was a significant association between PAI-1 4G/5G polymorphism and sepsis-related mortality (OR = 1.72, 95% CI 1.27–2.33, P = 0.0005). In subgroup analyses, increased sepsis risk and mortality risk were found in Caucasians and in patients with sepsis. Conclusions This meta-analysis suggested that the PAI-1 -675 4G/5G polymorphism was a risk factor for sepsis and sepsis mortality. PMID:23382992

  3. Basic Characteristics of Laser Heating in Thermoluminescence and of Laser-Stimulated Luminescence

    DTIC Science & Technology

    1990-07-15

    as examples. These include LiF:Mg,Ti ( TLD -100, Harshaw Chemical Corporation) in form of chips, which are widely used in the dosimetry of ionizing...take dosimetry ( TLD ) of ionizing radiation because it holds pro- the form of discrete circular spots whose diameter is smaller mise as a solution to...function of typical phosphor, we choose the most widely used dosimetry time after onset of the laser exposure, the time-dependent material LiF:Mg,Ti ( TLD

  4. Plasminogen activator inhibitor-1 4G/5G polymorphism in infertile women with and without endometriosis.

    PubMed

    Gonçalves-Filho, Rubens P; Brandes, Ariel; Christofolini, Denise M; Lerner, Tatiana G; Bianco, Bianca; Barbosa, Caio P

    2011-05-01

    To evaluate PAI-1 genotypes in a group of infertile women with or without endometriosis and control subjects. Case-control study. Human Reproduction Center of Medicina do ABC Faculty. One hundred and forty infertile women with endometriosis, 64 women with idiopathic infertility and 148 fertile women as control subjects. The PAI-1 4G/5G polymorphism was identified by restriction fragment length polymorphism-polymerase chain reaction. Genotype distribution and allele frequency of the 4G/5G polymorphism of the PAI-1 gene. The frequencies of genotypes 4G/4G, 4G/5G and 5G/5G of the PAI-1 gene in the infertile women with endometriosis were 38.6, 37.1 and 24.3%, respectively, and in the control group 24.3, 33.8 and 41.9%, respectively (p=0.003). When the infertile women with endometriosis were divided according to their endometriosis stage, genotypes 4G/4G, 4G/5G and 5G/5G were identified, respectively, in 36.7, 32.9 and 30.4% of the patients with minimal/mild endometriosis (p=0.102) and in 41.0, 42.6 and 16.4% of the patients with moderate/severe endometriosis (p=0.001); in the women with idiopathic infertility, these genotypes were found at a frequency of 29.7, 34.3 and 36%, respectively (p=0.637). The data suggest that, in Brazilian women, the PAI-1 4G/5G polymorphism may be associated with a risk of endometriosis-associated infertility. © 2011 The Authors Acta Obstetricia et Gynecologica Scandinavica© 2011 Nordic Federation of Societies of Obstetrics and Gynecology.

  5. 26 CFR 1.430(g)-1 - Valuation date and valuation of plan assets.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....430(g)-1 Section 1.430(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Certain Stock Options § 1.430(g)-1 Valuation date... plan's valuation date and the valuation of a plan's assets for a plan year under section 430(g...

  6. 26 CFR 1.430(g)-1 - Valuation date and valuation of plan assets.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....430(g)-1 Section 1.430(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Certain Stock Options § 1.430(g)-1 Valuation date... plan's valuation date and the valuation of a plan's assets for a plan year under section 430(g...

  7. 26 CFR 1.430(g)-1 - Valuation date and valuation of plan assets.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ....430(g)-1 Section 1.430(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Certain Stock Options § 1.430(g)-1 Valuation date... plan's valuation date and the valuation of a plan's assets for a plan year under section 430(g...

  8. The association between plasminogen activator inhibitor type 1 (PAI-1) levels, PAI-1 4G/5G polymorphism, and myocardial infarction: a Mendelian randomization meta-analysis.

    PubMed

    Nikolopoulos, Georgios K; Bagos, Pantelis G; Tsangaris, Iraklis; Tsiara, Chrissa G; Kopterides, Petros; Vaiopoulos, Aristides; Kapsimali, Violetta; Bonovas, Stefanos; Tsantes, Argirios E

    2014-07-01

    The circulating levels of plasminogen activator inhibitor type 1 (PAI-1) are increased in individuals carrying the 4G allele at position -675 of the PAI-1 gene. In turn, overexpression of PAI-1 has been found to affect both atheroma and thrombosis. However, the association between PAI-1 levels and the incidence of myocardial infarction (MI) is complicated by the potentially confounding effects of well-known cardiovascular risk factors. The current study tried to investigate in parallel the association of PAI-1 activity with the PAI-1 4G/5G polymorphism, with MI, and some components of metabolic syndrome (MetS). Using meta-analytical Mendelian randomization approaches, genotype-disease and genotype-phenotype associations were modeled simultaneously. According to an additive model of inheritance and the Mendelian randomization approach, the MI-related odd ratio for individuals carrying the 4G allele was 1.088 with 95% confidence interval (CI) 1.007, 1.175. Moreover, the 4G carriers had, on average, higher PAI-1 activity than 5G carriers by 1.136 units (95% CI 0.738, 1.533). The meta-regression analyses showed that the levels of triglycerides (p=0.005), cholesterol (p=0.037) and PAI-1 (p=0.021) in controls were associated with the MI risk conferred by the 4G carriers. The Mendelian randomization meta-analysis confirmed previous knowledge that the PAI-1 4G allele slightly increases the risk for MI. In addition, it supports the notion that PAI-1 activity and established cardiovascular determinants, such as cholesterol and triglyceride levels, could lie in the etiological pathway from PAI-1 4G allele to the occurrence of MI. Further research is warranted to elucidate these interactions.

  9. Thermoluminescence dosimetry and its applications in medicine--Part 2: History and applications.

    PubMed

    Kron, T

    1995-03-01

    Thermoluminescence dosimetry (TLD) has been available for dosimetry of ionising radiation for nearly 100 years. The variety of materials and their different physical forms allow the determination of different radiation qualities over a wide range of absorbed dose. This makes TL dosimeters useful in radiation protection where dose levels of microGy are monitored as well as in radiotherapy where doses up to several Gray are to be measured. The major advantages of TL detectors are their small physical size and that no cables or auxiliary equipment is required during the dose assessment. Therefore TLD is a good method for point dose measurements in phantoms as well as for in vivo dosimetry on patients during radiotherapy treatment. As an integrative dosimetric technique, it can be applied to personal dosimetry and it lends itself to the determination of dose distributions due to multiple or moving radiation sources (e.g. conformal and dynamic radiotherapy, computed tomography). In addition, TL dosimeters are easy to transport, and they can be mailed. This makes them well suited for intercomparison of doses delivered in different institutions. The present article aims at describing the various applications TLD has found in medicine by taking into consideration the physics and practice of TLD measurements which have been discussed in the first part of this review (Australas. Phys. Eng. Sci. Med. 17: 175-199, 1994).

  10. Disease-associated extracellular loop mutations in the adhesion G protein-coupled receptor G1 (ADGRG1; GPR56) differentially regulate downstream signaling.

    PubMed

    Kishore, Ayush; Hall, Randy A

    2017-06-09

    Mutations to the adhesion G protein-coupled receptor ADGRG1 (G1; also known as GPR56) underlie the neurological disorder bilateral frontoparietal polymicrogyria. Disease-associated mutations in G1 studied to date are believed to induce complete loss of receptor function through disruption of either receptor trafficking or signaling activity. Given that N-terminal truncation of G1 and other adhesion G protein-coupled receptors has been shown to significantly increase the receptors' constitutive signaling, we examined two different bilateral frontoparietal polymicrogyria-inducing extracellular loop mutations (R565W and L640R) in the context of both full-length and N-terminally truncated (ΔNT) G1. Interestingly, we found that these mutations reduced surface expression of full-length G1 but not G1-ΔNT in HEK-293 cells. Moreover, the mutations ablated receptor-mediated activation of serum response factor luciferase, a classic measure of Gα 12/13 -mediated signaling, but had no effect on G1-mediated signaling to nuclear factor of activated T cells (NFAT) luciferase. Given these differential signaling results, we sought to further elucidate the pathway by which G1 can activate NFAT luciferase. We found no evidence that ΔNT activation of NFAT is dependent on Gα q/11 -mediated or β-arrestin-mediated signaling but rather involves liberation of Gβγ subunits and activation of calcium channels. These findings reveal that disease-associated mutations to the extracellular loops of G1 differentially alter receptor trafficking, depending on the presence of the N terminus, and differentially alter signaling to distinct downstream pathways. © 2017 by The American Society for Biochemistry and Molecular Biology, Inc.

  11. The association between PAI-1 -675 4G/5G polymorphism and type 2 diabetes mellitus.

    PubMed

    Chen, L; Li, S-Y; Liu, M

    2017-08-15

    In this study, we aimed to analyze the association between plasminogen activator inhibitor 1 (PAI-1) -675 4G/5G polymorphism and type 2 diabetes mellitus (T2DM) risk. We included in 187 T2DM patients and 186 heathy controls between 2014 and 2017 from Tianjin Gong An Hospital, China. All patients and controls were ethnically Chinese Han population. The primers and polymerase chain reaction (PCR) conditions were performed. Results from this case-control study suggested that PAI-1 -675 4G/5G polymorphism was not associated with T2DM risk in four genetic models. Additionally, PAI-1 -675 4G/5G polymorphism was not associated with clinical and laboratory characteristics, such as age, gender, body mass index, systolic blood pressure, diastolic blood pressure, total cholesterol, triglycerides, and HbA1c. In conclusion, this case-control study suggested that PAI-1 -675 4G/5G polymorphism was not associated with T2DM risk in this population.

  12. PAI-1 promoter 4G/5G polymorphism (rs1799768) contributes to tumor susceptibility: Evidence from meta-analysis.

    PubMed

    Xu, Xin; Xie, Yanqi; Lin, Yiwei; Xu, Xianglai; Zhu, Yi; Mao, Yeqing; Hu, Zhenghui; Wu, Jian; Chen, Hong; Zheng, Xiangyi; Qin, Jie; Xie, Liping

    2012-12-01

    Plasminogen activator inhibitor-1 (PAI-1), belonging to the urokinase plasminogen activation (uPA) system, is involved in cancer development and progression. The PAI-1 promoter 4G/5G polymorphism was shown to contribute to genetic susceptibility to cancer, although the results were inconsistent. To assess this relationship more precisely, a meta-analysis was performed. The electronic databases PubMed, Scopus, Web of Science and Chinese National Knowledge Infrastructure (CNKI) were searched; data were extracted and analyzed independently by two reviewers. Ultimately, 21 eligible case-control studies with a total of 8,415 cancer cases and 9,208 controls were included. The overall odds ratio (OR) with its 95% confidence interval (CI) showed a statistically significant association between the PAI-1 promoter 4G/5G polymorphism and cancer risk (4G/4G vs. 5G/5G: OR=1.25, 95% CI=1.07-1.47, P(heterogeneity)=0.001; 4G/4G vs. 4G/5G+5G/5G: OR=1.10, 95% CI=1.03-1.17, P(heterogeneity)=0.194; 4G/4G+4G/5G vs. 5G/5G: OR=1.17, 95% CI=1.01-1.35, P(heterogeneity)=0.041). In further subgroup analyses, the increased risk of cancer was observed in a subgroup of Caucasians with regards to endometrial cancer. Our meta-analysis suggests that the PAI-1 4G/5G polymorphism most likely contributes to susceptibility to cancer, particularly in Caucasians. Furthermore, the 4G allele may be associated with an increased risk of endometrial cancer.

  13. PAI-1 promoter 4G/5G polymorphism (rs1799768) contributes to tumor susceptibility: Evidence from meta-analysis

    PubMed Central

    XU, XIN; XIE, YANQI; LIN, YIWEI; XU, XIANGLAI; ZHU, YI; MAO, YEQING; HU, ZHENGHUI; WU, JIAN; CHEN, HONG; ZHENG, XIANGYI; QIN, JIE; XIE, LIPING

    2012-01-01

    Plasminogen activator inhibitor-1 (PAI-1), belonging to the urokinase plasminogen activation (uPA) system, is involved in cancer development and progression. The PAI-1 promoter 4G/5G polymorphism was shown to contribute to genetic susceptibility to cancer, although the results were inconsistent. To assess this relationship more precisely, a meta-analysis was performed. The electronic databases PubMed, Scopus, Web of Science and Chinese National Knowledge Infrastructure (CNKI) were searched; data were extracted and analyzed independently by two reviewers. Ultimately, 21 eligible case-control studies with a total of 8,415 cancer cases and 9,208 controls were included. The overall odds ratio (OR) with its 95% confidence interval (CI) showed a statistically significant association between the PAI-1 promoter 4G/5G polymorphism and cancer risk (4G/4G vs. 5G/5G: OR=1.25, 95% CI=1.07–1.47, Pheterogeneity=0.001; 4G/4G vs. 4G/5G+5G/5G: OR=1.10, 95% CI=1.03–1.17, Pheterogeneity=0.194; 4G/4G+4G/5G vs. 5G/5G: OR=1.17, 95% CI=1.01–1.35, Pheterogeneity=0.041). In further subgroup analyses, the increased risk of cancer was observed in a subgroup of Caucasians with regards to endometrial cancer. Our meta-analysis suggests that the PAI-1 4G/5G polymorphism most likely contributes to susceptibility to cancer, particularly in Caucasians. Furthermore, the 4G allele may be associated with an increased risk of endometrial cancer. PMID:23226787

  14. Geologic map of the Priest Rapids 1:100,000 quadrangle, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reidel, S.P.; Fecht, K.R.

    1993-09-01

    This map of the Priest Rapids 1:100,000-scale quadrangle, Washington, shows the geology of one of fifteen complete or partial 1:100,000-scale quadrangles that cover the southeast quadrant of Washington. Geologic maps of these quadrangles have been compiled by geologists with the Washington Division of Geology and Earth Resources (DGER) and Washington State University and are the principal data sources for a 1:250,000scale geologic map of the southeast quadrant of Washington, which is in preparation. Eleven of those quadrangles are being released as DGER open-file reports (listed below). The map of the Wenatchee quadrangle has been published by the US Geological Surveymore » (Tabor and others, 1982), and the Moses Lake (Gulick, 1990a), Ritzville (Gulick, 1990b), and Rosalia (Waggoner, 1990) quadrangles have already been released. The geology of the Priest Rapids quadrangle has not previously been compiled at 1:100,000 scale. Furthermore, this is the first 1:100,000 or smaller scale geologic map of the area to incorporate both bedrock and surficial geology. This map was compiled in 1992, using published and unpublished geologic maps as sources of data.« less

  15. Thermoluminescence responses of photon- and electron-irradiated lithium potassium borate co-doped with Cu+Mg or Ti+Mg.

    PubMed

    Alajerami, Y S M; Hashim, S; Ramli, A T; Saleh, M A; Saripan, M I; Alzimami, K; Min Ung, Ngie

    2013-08-01

    New glasses Li2CO3-K2CO3-H3BO3 (LKB) co-doped with CuO and MgO, or with TiO2 and MgO, were synthesized by the chemical quenching technique. The thermoluminescence (TL) responses of LKB:Cu,Mg and LKB:Ti,Mg irradiated with 6 MV photons or 6 MeV electrons were compared in the dose range 0.5-4.0 Gy. The standard commercial dosimeter LiF:Mg,Ti (TLD-100) was used to calibrate the TL reader and as a reference in comparison of the TL properties of the new materials. The dependence of the responses of the new materials on (60)Co dose is linear in the range of 1-1000 Gy. The TL yields of both of the co-doped glasses and TLD-100 are greater for electron irradiation than for photon irradiation. The TL sensitivity of LKB:Ti,Mg is 1.3 times higher than the sensitivity of LKB:Cu,Mg and 12 times less than the sensitivity of TLD-100. The new TL dosimetric materials have low effective atomic numbers, good linearity of the dose responses, excellent signal reproducibility, and a simple glow curve structure. This combination of properties makes them suitable for radiation dosimetry. Copyright © 2013 Elsevier Ltd. All rights reserved.

  16. Biotransformation of aflatoxin B1 and aflatoxin G1 in peanut meal by anaerobic solid fermentation of Streptococcus thermophilus and Lactobacillus delbrueckii subsp. bulgaricus.

    PubMed

    Chen, Yujie; Kong, Qing; Chi, Chen; Shan, Shihua; Guan, Bin

    2015-10-15

    The purpose of this study was to explore the ability of anaerobic solid fermentation of Streptococcus thermophilus and Lactobacillus delbrueckii subsp. bulgaricus to biotransform aflatoxins in peanut meal. The pH of the peanut meal was adjusted above 10, and then heated for 10 min at 100 °C, 115 °C and 121 °C. The S. thermophilus and L. delbrueckii subsp. bulgaricus were precultured together in MRS broth for 48 h at 37 °C. The heated peanut meal was mixed with precultured MRS broth containing 7.0×10(8) CFU/mL of S. thermophilus and 3.0×10(3) CFU/mL of L. delbrueckii subsp. bulgaricus with the ratio of 1 to 1 (weight to volume) and incubated in anaerobic jars at 37 °C for 3 days. The aflatoxin content in the peanut meal samples was determined by HPLC. The results showed that the peanut meal contained mainly aflatoxin B1 (AFB1) (10.5±0.64 μg/kg) and aflatoxin G1 (AFG1) (18.7±0.55 μg/kg). When heat treatment was combined with anaerobic solid fermentation, the biotransformation rate of aflatoxins in peanut meal could attain 100%. The cytotoxicity of fermented peanut meal to L929 mouse connective tissue fibroblast cells was determined by MTT assay and no significant toxicity was observed in the fermented peanut meal. Furthermore, heat treatment and anaerobic solid fermentation did not change the amino acid concentrations and profile in peanut meal. Copyright © 2015 Elsevier B.V. All rights reserved.

  17. Gas kinematics in the H II regions G351.69-1.15 and G351.63-1.25

    NASA Astrophysics Data System (ADS)

    Veena, V. S.; Vig, S.; Tej, A.; Kantharia, N. G.; Ghosh, S. K.

    2017-03-01

    We probe the structure and kinematics of two neighbouring H II regions identified as cometary and bipolar, using radio recombination lines (RRLs). The H172α RRLs from these H II regions: G351.69-1.15 and G351.63-1.25, are mapped using Giant Metrewave Radio Telescope, India. We also detect carbon RRLs C172α towards both these regions. The hydrogen RRLs display the effects of pressure and dynamical broadening in the line profiles, with the dynamical broadening (∼15 km s-1) playing a major role in the observed profile of G351.69-1.15. We investigate the kinematics of molecular gas species towards this H II region from the Millimetre Astronomy Legacy Team 90 GHz Pilot Survey. The molecular gas is mostly distributed towards the north and north-west of the cometary head. The molecular line profiles indicate signatures of turbulence and outflow in this region. The ionized gas at the cometary tail is blueshifted by ∼8 km s-1 with respect to the ambient molecular cloud, consistent with the earlier proposed champagne flow scenario. The relative velocity of ∼5 km s-1 between the northern and southern lobes of the bipolar H II region G351.63-1.25 is consistent with the premise that the bipolar morphology is a result of the expanding ionized lobes within a flat molecular cloud.

  18. Serum apolipoprotein B-100 concentration predicts the virological response to pegylated interferon plus ribavirin combination therapy in patients infected with chronic hepatitis C virus genotype 1b.

    PubMed

    Yoshizawa, Kai; Abe, Hiroshi; Aida, Yuta; Ishiguro, Haruya; Ika, Makiko; Shimada, Noritomo; Tsubota, Akihito; Aizawa, Yoshio

    2013-07-01

    Host lipoprotein metabolism is associated closely with the life cycle of hepatitis C virus (HCV), and serum lipid profiles have been linked to the response to pegylated interferon (Peg-IFN) plus ribavirin (RBV) therapy. Polymorphisms in the human IL28B gene and amino acid substitutions in the core and interferon sensitivity-determining region (ISDR) in NS5A of HCV genotype 1b (G1b) were also shown to strongly affect the outcome of Peg-IFN plus RBV therapy. In this study, an observational cohort study was performed in 247 HCV G1b-infected patients to investigate whether the response to Peg-IFN and RBV combination therapy in these patients is independently associated with the level of lipid factors, especially apolipoprotein B-100 (apoB-100), an obligatory structural component of very low density lipoprotein and low density lipoprotein. The multivariate logistic analysis subsequently identified apoB-100 (odds ratio (OR), 1.602; 95% confidence interval (CI), 1.046-2.456), alpha-fetoprotein (OR, 0.764; 95% CI, 0.610-0.958), non-wild-type ISDR (OR, 5.617; 95% CI, 1.274-24.754), and the rs8099917 major genotype (OR, 34.188; 95% CI, 10.225-114.308) as independent factors affecting rapid initial virological response (decline in HCV RNA levels by ≥3-log10 at week 4). While lipid factors were not independent predictors of complete early or sustained virological response, the serum apoB-100 level was an independent factor for sustained virological response in patients carrying the rs8099917 hetero/minor genotype. Together, we conclude that serum apoB-100 concentrations could predict virological response to Peg-IFN plus RBV combination therapy in patients infected with HCV G1b, especially in those with the rs8099917 hetero/minor genotype. Copyright © 2013 Wiley Periodicals, Inc.

  19. PAI-1 4G/5G polymorphism and plasma levels association in patients with coronary artery disease.

    PubMed

    Lima, Luciana Moreira; Carvalho, Maria das Graças; Fonseca Neto, Cirilo Pereira; Garcia, José Carlos Faria; Sousa, Marinez Oliveira

    2011-12-01

    Type-1 plasminogen activator inhibitor (PAI-1) 4G/5G polymorphism may influence the PAI-1 expression. High plasma levels of PAI-1 are associated with coronary artery disease (CAD). This study investigated the influence of PAI-1 4G/5G polymorphism on plasma PAI-1 levels and its association with CAD assessed by coronary angiography. Blood sample of 35 individuals with angiographically normal coronary arteries, 31 individuals presenting mild/moderate atheromatosis, 57 individuals presenting severe atheromatosis and 38 healthy individuals (controls) were evaluated. In patients and controls, the PAI-1 4G/5G polymorphism was determined by PCR amplification using allele-specific primers. Plasma PAI-1 levels were quantified by ELISA assay (American Diagnostica). No difference was found between groups regarding age, gender and body mass index. Plasma PAI-1 levels and 4G/4G genotype frequency were significantly higher in the severe atheromatosis group compared to the other groups (p<0.001). Furthermore, patients with 4G/4G genotype (r=0.28, p<0.001) had significantly higher plasma PAI-1 levels than those with 5G/5G genotype (r=0.02, p=0.4511). In addition, in a multiple logistic regression model, adjusted for all the other variables, PAI-1 was observed to be independently associated with CAD > 70% (p<0.001). The most important finding of this study was the association between 4G/4G genotype, high plasma PAI-1 levels and coronary stenosis higher than 70% in Brazilian individuals. Whether high plasma PAI-1 levels are a decisive factor for atherosclerosis worsening or it is a consequence remains to be established.

  20. 26 CFR 1.860G-1 - Definition of regular and residual interests.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Real Estate Investment Trusts § 1.860G-1... or the amount of income from permitted investments (as defined in § 1.860G-2(g)); or (B) The timing... interest is affected by defaults on qualified mortgages and permitted investments, unanticipated expenses...

  1. 26 CFR 1.860G-1 - Definition of regular and residual interests.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Real Estate Investment Trusts § 1.860G-1... or the amount of income from permitted investments (as defined in § 1.860G-2(g)); or (B) The timing... interest is affected by defaults on qualified mortgages and permitted investments, unanticipated expenses...

  2. 26 CFR 1.860G-1 - Definition of regular and residual interests.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Real Estate Investment Trusts § 1.860G-1... or the amount of income from permitted investments (as defined in § 1.860G-2(g)); or (B) The timing... interest is affected by defaults on qualified mortgages and permitted investments, unanticipated expenses...

  3. 26 CFR 1.860G-1 - Definition of regular and residual interests.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... (CONTINUED) INCOME TAX (CONTINUED) INCOME TAXES (CONTINUED) Real Estate Investment Trusts § 1.860G-1... or the amount of income from permitted investments (as defined in § 1.860G-2(g)); or (B) The timing... interest is affected by defaults on qualified mortgages and permitted investments, unanticipated expenses...

  4. Ethyl acetate fraction of Garcina epunctata induces apoptosis in human promyelocytic cells (HL-60) through the ROS generation and G0/G1 cell cycle arrest: a bioassay-guided approach.

    PubMed

    Constant Anatole, Pieme; Guru, Santoh Kumar; Bathelemy, Ngamegni; Jeanne, Ngogang; Bhushan, Shashi; Murayama, Tetsuya; Saxena, Ajit Kumar

    2013-11-01

    Number of deaths due to cancer diseases is increasing in the world. There is an urgent need to develop alternative therapeutic measures against the disease. Our study reports the cytotoxicity activity of Garcina epunctata (gutifferae) in human promyelocytic leukemia cells (HL-60) and prostate cancer cells (PC-3) was evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT). Changes in mitochondrial membrane potential (MMP), reactive oxygen species (ROS) and morphological changes associated with apoptosis were examined by flow cytometry and Hoescht staining respectively. The results of in vitro antiproliferative screening of fractions and extract from G. epunctata indicated that three fractions inhibited the viability of PC-3 cells with IC₅₀ varied from 50 to 88 μ/ml while two fractions inhibited the proliferation of HL-60 cells with IC₅₀ range between 47.5 and 12 μg/ml. Among the entire fraction tested, Hex-EtOAc (75:25) showed cytotoxic effects on the two cell lines and EtOAc fraction was most active only HL-60 cells (12 μg/ml). Treatment of HL-60 cells with G. epunctata (20, 50, 100 μg/ml) for 24 h led to a significant dose-dependent increase in the percentage of cells in sub-G1 phase by analysis of the content of DNA in cells, and a number of apoptotic bodies containing nuclear fragments were observed in cells treated with 100 μg/ml. The EtOAc fraction of G. epunctata treatment significantly arrested HL-60 cells at the G0/G1 phase (p<0.05) and ROS was significantly elevated as well as the loss of membrane mitochondrial potential in a concentration dependant manner. The results demonstrated that the EtOAc fraction of G. epunctata inhibited the proliferation of HL-60 cells, leading to cell cycle arrest and programmed cell death, which was confirmed to occur through the mitochondrial pathway. Copyright © 2013 Elsevier B.V. All rights reserved.

  5. Association between plasminogen activator inhibitor-1 4G/5G gene polymorphism and immunoglobulin A nephropathy susceptibility.

    PubMed

    Zhou, Tian-Biao; Jiang, Zong-Pei

    2015-02-01

    The association between plasminogen activator inhibitor-1 (PAI-1) 4 G/5 G gene polymorphism and immunoglobulin A nephropathy (IgAN) risk is still controversial. A meta-analysis was performed to evaluate the association between PAI-1 4 G/5 G gene polymorphism and IgAN susceptibility. A predefined literature search and selection of eligible relevant studies were performed to collect data from electronic database. Four articles were identified for the analysis of association between PAI-1 4 G/5 G gene polymorphism and IgAN risk. 4 G allele was not associated with IgAN susceptibility in overall populations and in Asians. Furthermore, 4 G/4 G and 5 G/5 G genotype were not associated with IgAN for overall populations, Asians. In conclusion, PAI-1 4 G/5 G gene polymorphism was not associated with IgAN risk in overall populations and in Asians. However, more studies should be performed in the future.

  6. 42 CFR 84.100 - Man tests 1, 2, 3, and 4; requirements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Man tests 1, 2, 3, and 4; requirements. 84.100...-Contained Breathing Apparatus § 84.100 Man tests 1, 2, 3, and 4; requirements. Man tests 1, 2, 3, and 4, set forth in Tables 1, 2, 3, and 4 of this subpart, respectively, prescribe the duration and sequence of...

  7. 17 CFR 100.1 - Delivery period required with respect to certain grains.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 17 Commodity and Securities Exchanges 1 2010-04-01 2010-04-01 false Delivery period required with respect to certain grains. 100.1 Section 100.1 Commodity and Securities Exchanges COMMODITY FUTURES... grains. A period of seven business days is required during which contracts for future delivery in the...

  8. The -675 4G/5G polymorphism at the Plasminogen Activator Inhibitor 1 (PAI-1) gene modulates plasma Plasminogen Activator Inhibitor 1 concentrations in response to dietary fat consumption.

    PubMed

    Pérez-Martínez, P; Adarraga-Cansino, M D; Fernández de la Puebla, R A; Blanco-Molina, A; Delgado-Lista, J; Marín, C; Ordovás, J M; López-Miranda, J; Pérez-Jiménez, F

    2008-04-01

    The objective of the study was to determine whether Plasminogen Activator Inhibitor Type 1 (PAI-1) -675 4G/5G polymorphism is associated with the response of functional plasma PAI-1 concentrations to changes in the amount and quality of dietary fat in healthy subjects. PAI-1 is the major inhibitor of fibrinolysis, and a lower level of fibrinolytic activity could be implicated in an increased risk of IHD. Fifty-nine healthy Spanish volunteers (ten 4G/4G homozygotes, twenty-eight heterozygotes 4G/5G and twenty-one 5G/5G homozygotes) consumed three diets for periods of 4 weeks each: a SFA-rich diet (38 % fat, 20 % SFA), followed by a carbohydrate-rich diet (30 % fat, 55 % carbohydrate) and a MUFA-rich diet (38 % fat, 22 % MUFA) according to a randomized crossover design. At the end of each dietary period plasma lipid and functional plasma PAI-1 concentrations were determined. Subjects carrying the 4G allele (4G/4G and 4G/5G) showed a significant decrease in PAI-1 concentrations after the MUFA diet, compared with the SFA-rich and carbohydrate-rich diets (genotype x diet interaction: P = 0.028). 5G/5G homozygotes had the lowest plasma PAI-1 concentrations compared with 4G/4G and 4G/5G subjects (genotype: P = 0.002), without any changes as a result of the amount and the quality of the dietary fat. In summary, no differences in plasma PAI-1 concentration response were found after changes in dietary fat intake in 5G/5G homozygotes, although these subjects displayed the lowest concentrations of PAI-1. On the other hand, carriers of the 4G allele are more likely to hyper-respond to the presence of MUFA in the diet because of a greater decrease in PAI-1 concentrations.

  9. Whole-genome analyses of DS-1-like human G2P[4] and G8P[4] rotavirus strains from Eastern, Western and Southern Africa

    PubMed Central

    Nyaga, Martin M.; Stucker, Karla M.; Esona, Mathew D.; Jere, Khuzwayo C.; Mwinyi, Bakari; Shonhai, Annie; Tsolenyanu, Enyonam; Mulindwa, Augustine; Chibumbya, Julia N.; Adolfine, Hokororo; Halpin, Rebecca A.; Roy, Sunando; Stockwell, Timothy B.; Berejena, Chipo; Seheri, Mapaseka L.; Mwenda, Jason M.; Steele, A. Duncan; Wentworth, David E.

    2018-01-01

    Group A rotaviruses (RVAs) with distinct G and P genotype combinations have been reported globally. We report the genome composition and possible origin of seven G8P[4] and five G2P[4] human RVA strains based on the genetic evolution of all 11 genome segments at the nucleotide level. Twelve RVA ELISA positive stool samples collected in the representative countries of Eastern, Southern and West Africa during the 2007–2012 surveillance seasons were subjected to sequencing using the Ion Torrent PGM and Illumina MiSeq platforms. A reference-based assembly was performed using CLC Bio’s clc_ref_assemble_long program, and full-genome consensus sequences were obtained. With the exception of the neutralising antigen, VP7, all study strains exhibited the DS-1-like genome constellation (P[4]-I2-R2-C2-M2-A2-N2-T2-E2-H2) and clustered phylogenetically with reference strains having a DS-1-like genetic backbone. Comparison of the nucleotide and amino acid sequences with selected global cognate genome segments revealed nucleotide and amino acid sequence identities of 81.7–100 % and 90.6–100 %, respectively, with NSP4 gene segment showing the most diversity among the strains. Bayesian analyses of all gene sequences to estimate the time of divergence of the lineage indicated that divergence times ranged from 16 to 44 years, except for the NSP4 gene where the lineage seemed to arise in the more distant past at an estimated 203 years ago. However, the long-term effects of changes found within the NSP4 genome segment should be further explored, and thus we recommend continued whole-genome analyses from larger sample sets to determine the evolutionary mechanisms of the DS-1-like strains collected in Africa. PMID:24952422

  10. Interaction of S100A1 with LATS1 promotes cell growth through regulation of the Hippo pathway in hepatocellular carcinoma.

    PubMed

    Guo, Qingping; Wang, Jiale; Cao, Zeyu; Tang, Yongchang; Feng, Chao; Huang, Feizhou

    2018-06-05

    Despite advances in surgery and chemotherapy, the prognosis of patients with hepatocellular carcinoma (HCC) remains poor. In the present study, the role of S100A1 in the progression of HCC was investigated. Immunohistochemical staining was used to measure the expression of S100A1 in HCC tissues. S100A1 was knocked down by siRNA. A battery of experiments was used to evaluate the biology functions of S100A1. It was found that S100A1 was upregulated in HCC tissues, and its upregulation was associated with a large tumor size, low differentiation and shorter survival time. The biological experiments demonstrated that S100A1 functions as an oncogene in HCC. It was also found that S100A1 knockdown enhanced the inhibitory effects of cisplatin on HCC cells. The results showed that the downregulation of S100A1 induced the phosphorylation of yes‑associated protein (YAP), and treatment with CHX demonstrated that the downregulation of S100A1 accelerated YAP protein degradation. The downregulation of S100A1 did not alter the expression of mammalian sterile 20‑like kinase (MST)1/2 or phosphorylated MST1/2, but upregulated the phosphorylation of large tumor suppressor kinase 1 (LATS1). It was further confirmed that S100A1 interacted with LATS1. LATS1 depletion significantly reduced the effects of S100A1 on cell growth rate and apoptosis, and there was a positive correlation between phosphorylated LATS1 and S100A1 in clinical samples, indicating that LATS1 was responsible for the S100A1-induced changes in cancer cell growth and Hippo signaling. In conclusion, the results of the present study indicated that S100A1 functions as an oncogene and may be a biomarker for the prognosis of patients with HCC. S100A1 exerted its oncogenic function by interacting with LATS1 and activating YAP. S100A1 may serve as a target for novel therapies in HCC.

  11. Restraint hypothermia in cold-exposed rats at 3 G and 1 G

    NASA Technical Reports Server (NTRS)

    Monson, C. B.; Horowitz, J. M.; Horwitz, B. A.

    1982-01-01

    The relationship between heat loss, heat production, and hypothermia was investigated in experiments with rats which determined if hypergravity affects heat production by altering oxygen consumption and if restraint modifies the ability of the rats to activate thermogenic mechanisms after cold exposure in a hypergravic field. Restrained and unrestrained rats were exposed for 1 hr periods to 1 G and 3 G at ambient temperatures of 24 C or 10 C, and the rate of oxygen consumption, the core temperatures, and the tail temperatures were measured. Results show that thermoregulatory mechanisms are impaired when rats are exposed to 3 G fields, and at 24 C as well as at 10 C this impairment leads to an inappropriate increase in heat loss.

  12. Effects of silencing S100A8 and S100A9 with small interfering RNA on the migration of CNE1 nasopharyngeal carcinoma cells.

    PubMed

    Yan, Lin-Lin; Huang, Yuan-Jiao; Yi, Xiang; Yan, Xue-Min; Cai, Yan; He, Qin; Han, Zi-Jian

    2015-06-01

    The calcium-binding S100 proteins are involved in functions such as cell growth, differentiation, migration, adhesion and signal transduction. S100A8 and S100A9 are highly expressed in a variety of tumor cells, and are implicated in tumor development and progression. However, the role of S100A8 and S100A9 in nasopharyngeal carcinoma (NPC) cell migration is unclear. The present study investigated the effect of S100A8 and S100A9 on migration using a NPC cell line, CNE1. The CNE1 cells were transfected with S100A8 or S100A9 small interfering RNA (siRNA). Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) was used to detect S100A8 and S100A9 gene expression. Following the downregulation of S100A8 or S100A9, the effects on cell migration were determined using wound-healing assays. The expression of matrix metalloproteinase-7 (MMP7), a member of the MMP family that is associated with tumor cell invasion and migration, was also detected by RT-qPCR. S100A8 and S100A9 siRNAs effectively suppressed S100A8 and S100A9 gene expression, and substantially inhibited the migration of the CNE1 cells. In addition, MMP7 expression was reduced to varying extents in S100A8 and S100A9 siRNA-treated cells compared with controls. Thus, S100A8 and S100A9 promoted the migration of CNE1 NPC cells.

  13. Effects of silencing S100A8 and S100A9 with small interfering RNA on the migration of CNE1 nasopharyngeal carcinoma cells

    PubMed Central

    YAN, LIN-LIN; HUANG, YUAN-JIAO; YI, XIANG; YAN, XUE-MIN; CAI, YAN; HE, QIN; HAN, ZI-JIAN

    2015-01-01

    The calcium-binding S100 proteins are involved in functions such as cell growth, differentiation, migration, adhesion and signal transduction. S100A8 and S100A9 are highly expressed in a variety of tumor cells, and are implicated in tumor development and progression. However, the role of S100A8 and S100A9 in nasopharyngeal carcinoma (NPC) cell migration is unclear. The present study investigated the effect of S100A8 and S100A9 on migration using a NPC cell line, CNE1. The CNE1 cells were transfected with S100A8 or S100A9 small interfering RNA (siRNA). Reverse transcription-quantitative polymerase chain reaction (RT-qPCR) was used to detect S100A8 and S100A9 gene expression. Following the downregulation of S100A8 or S100A9, the effects on cell migration were determined using wound-healing assays. The expression of matrix metalloproteinase-7 (MMP7), a member of the MMP family that is associated with tumor cell invasion and migration, was also detected by RT-qPCR. S100A8 and S100A9 siRNAs effectively suppressed S100A8 and S100A9 gene expression, and substantially inhibited the migration of the CNE1 cells. In addition, MMP7 expression was reduced to varying extents in S100A8 and S100A9 siRNA-treated cells compared with controls. Thus, S100A8 and S100A9 promoted the migration of CNE1 NPC cells. PMID:26137102

  14. Measurement of computed tomography dose profile with pitch variation using Gafchromic XR-QA2 and thermoluminescence dosimeter (TLD)

    NASA Astrophysics Data System (ADS)

    Purwaningsih, S.; Lubis, L. E.; Pawiro, S. A.; Soejoko, D. S.

    2016-03-01

    This research was aimed to check the patterns of dose profile on adult and pediatric head scan. We compared measurement result on dose profile along the z- axis rotation at peripheries and center phantom with a variety of pitch, i.e. 0.75, 1, 1.5 for adult and pediatric head protocol, keeping the rest of the scan parameters constant. Measurements were performed on homogeneous, cylindrical PMMA phantom with diameters of 16 and 10 cm using XR-QA2 Gafchromic film and TLD as dosimeters. The measurement result indicated a decrease in the dose about 50% and 47% for adult and pediatric head scan with the increase of pitch. For 0.75 value of pitch adult head scan, dose range for each position were (2.4 - 5.0) cGy, (3.1 - 5.3) cGy, (2.2 - 4.5) cGy, (2.8 - 5.3) cGy, and (3.3 - 5.6) cGy for position of center, 3, 6, 9 and 12 o'clock peripheral phantom position respectively. Dose profile for adult and pediatric head scan protocols has pattern curve with the maximum dose in the middle and tendency of symmetry near the edges, with different the plateau length along z- axis direction in accordance to the measurement position in the phantom.

  15. Optimization of chromatographic conditions for determination of aflatoxin B1, B2, G1 and G2 by using liquid chromatography-mass Spectrometry

    NASA Astrophysics Data System (ADS)

    Ramadhaningtyas, Dillani Putri; Aryana, Nurhani; Aristiawan, Yosi; Styarini, Dyah

    2017-11-01

    The optimization of instrument condition and chromatographic separation for analysis of aflatoxin B1, B2, G1 and G2 using liquid chromatography tandem with mass spectrometer detector was conducted in the aim to provide more accurate and reliable analysis results. The aflatoxin known to be serious threat for human health as it is classified as the carcinogenic compounds. The aflatoxin B1, B2, G1 and G2 were selected due to its extensive contamination in various agricultural commodities. The best chromatographic separation was obtained using C-18 column with gradient elution of solvent 5 mM ammonium acetate and 0.1% formic acid in methanol at 7 minutes runtime analysis. The linearity of the detector showed satisfied results as the coefficient determination found to be 0.9994, 0.9996, 0.9998 and 0.9987 for aflatoxin B1, G1, B2, and G2 respectively in the range concentration from 1 to 20 ng/g. The quantifier ion selected for the aflatoxin B1, B2, G1 and G2 was m/z 285.1, 259, 243 and 313 respectively. The instrument precision at these quantifier ions also showed satisfied result with %RSD was around 3.4 to 6.8%. The optimized method present in this study can be used for further sample analysis.

  16. Plasminogen activator inhibitor-1 4G/5G polymorphism is associated with type 2 diabetes risk

    PubMed Central

    Zhao, Luqian; Huang, Ping

    2013-01-01

    A number of studies were performed to assess the association between plasminogen activator inhibitor-1 (PAI-1) 4G/5G polymorphism and susceptibility to type 2 diabetes (T2DM). However, the results were inconsistent and inconclusive. In the present study, the possible association was investigated by a meta-analysis. Eligible articles were identified for the period up to June 2013. Pooled odds ratios (OR) with 95% confidence intervals (CI) were appropriately derived from random-effects models or fixed-effects models. Fourteen case-control studies with a total of 2487 cases and 3538 controls were eligible. In recessive model, PAI-1 4G/5G polymorphism was associated with T2DM risk (OR = 1.23; 95% CI 1.07-1.41; P = 0.004). In the subgroup analysis by ethnicity, a significant association was found among Asians (OR = 1.27; 95% CI 1.08-1.51; P = 0.005). This meta-analysis suggested that PAI-1 4G/5G polymorphism may be associated with T2DM development. PMID:24040470

  17. 26 CFR 1.1502-100 - Corporations exempt from tax.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 1201(a) on the consolidated unrelated business taxable income for the year (determined under paragraph... consolidated return year shall be determined by taking into account: (1) The separate unrelated business... 26 Internal Revenue 12 2010-04-01 2010-04-01 false Corporations exempt from tax. 1.1502-100...

  18. A comparative study of the thermoluminescent response to beta irradiation of CVD diamond and LiF dosimeters

    NASA Astrophysics Data System (ADS)

    Bogani, F.; Borchi, E.; Bruzzi, M.; Leroy, C.; Sciortino, S.

    1997-02-01

    The thermoluminescent (TL) response of Chemical Vapour Deposited (CVD) diamond films to beta irradiation has been investigated. A numerical curve-fitting procedure, calibrated by means of a set of LiF TLD100 experimental spectra, has been developed to deconvolute the complex structured TL glow curves. The values of the activation energy and of the frequency factor related to each of the TL peaks involved have been determined. The TL response of the CVD diamond films to beta irradiation has been compared with the TL response of a set of LiF TLD100 and TLD700 dosimeters. The results have been discussed and compared in view of an assessment of the efficiency of CVD diamond films in future applications as in vivo dosimeters.

  19. TopBP1 functions with 53BP1 in the G1 DNA damage checkpoint

    PubMed Central

    Cescutti, Rachele; Negrini, Simona; Kohzaki, Masaoki; Halazonetis, Thanos D

    2010-01-01

    TopBP1 is a checkpoint protein that colocalizes with ATR at sites of DNA replication stress. In this study, we show that TopBP1 also colocalizes with 53BP1 at sites of DNA double-strand breaks (DSBs), but only in the G1-phase of the cell cycle. Recruitment of TopBP1 to sites of DNA replication stress was dependent on BRCT domains 1–2 and 7–8, whereas recruitment to sites of DNA DSBs was dependent on BRCT domains 1–2 and 4–5. The BRCT domains 4–5 interacted with 53BP1 and recruitment of TopBP1 to sites of DNA DSBs in G1 was dependent on 53BP1. As TopBP1 contains a domain important for ATR activation, we examined whether it contributes to the G1 cell cycle checkpoint. By monitoring the entry of irradiated G1 cells into S-phase, we observed a checkpoint defect after siRNA-mediated depletion of TopBP1, 53BP1 or ATM. Thus, TopBP1 may mediate the checkpoint function of 53BP1 in G1. PMID:20871591

  20. TopBP1 functions with 53BP1 in the G1 DNA damage checkpoint.

    PubMed

    Cescutti, Rachele; Negrini, Simona; Kohzaki, Masaoki; Halazonetis, Thanos D

    2010-11-03

    TopBP1 is a checkpoint protein that colocalizes with ATR at sites of DNA replication stress. In this study, we show that TopBP1 also colocalizes with 53BP1 at sites of DNA double-strand breaks (DSBs), but only in the G1-phase of the cell cycle. Recruitment of TopBP1 to sites of DNA replication stress was dependent on BRCT domains 1-2 and 7-8, whereas recruitment to sites of DNA DSBs was dependent on BRCT domains 1-2 and 4-5. The BRCT domains 4-5 interacted with 53BP1 and recruitment of TopBP1 to sites of DNA DSBs in G1 was dependent on 53BP1. As TopBP1 contains a domain important for ATR activation, we examined whether it contributes to the G1 cell cycle checkpoint. By monitoring the entry of irradiated G1 cells into S-phase, we observed a checkpoint defect after siRNA-mediated depletion of TopBP1, 53BP1 or ATM. Thus, TopBP1 may mediate the checkpoint function of 53BP1 in G1.

  1. Neutron Fading Characteristics of Copper Doped Lithium Fluoride (LiF: MCP) Thermoluminescent Dosimeters (TLDs)

    DTIC Science & Technology

    2008-05-21

    Albedo Dosimetry TLDs that are used for neutron or neutron-photon personnel dosimetry are albedo dosimeters. The word albedo simply means the proportion... dosimetry . When LiF: MCP is exposed to thermal neutron irradiation, there is no obvious change in the glow curve shape. In the case of TLD -100, the...LiF: MCP undergoes compared to TLD -100. Therefore, LET results in significant variations in TL output for LiF: MCP. Limitations of Albedo Dosimetry

  2. Gestational Diabetes Mellitus (GDM): Relationship Between Higher Cutoff Values for 100 g Oral Glucose Tolerance Test (OGTT) and Insulin Requirement During Pregnancy.

    PubMed

    Ares, Jessica; Martín-Nieto, Alicia; Díaz-Naya, Lucía; Tartón, Teresa; Menéndez-Prada, Teresa; Ragnarsson, Cecilia S; Delgado-Álvarez, Elías; Menéndez-Torre, Edelmiro

    2017-07-01

    Objectives To study if there is any relationship about higher cutoff values for 100 g oral glucose tolerance test and the need for insulin in women diagnosed with gestational diabetes. Materials and Methods This is a retrospective population-based study of 201 women diagnosed with Gestational Diabetes Mellitus (GDM) between January 2012 and June 2014 in the area of Oviedo, Asturias, Spain. According to diagnostic criteria recommended by GEDE, NDDG, gestational diabetes is diagnosed if two or more plasma glucose levels meet or exceed the following threshold: fasting glucose of 105 mg/dl, 1-h 190 mg/dl, 2-h 165 mg/dl, or 3-h 145 mg/dl. We aim to know if there is any relationship between higher cutoffs and insulin requirement. Results 36 out of 201 patients (17.91%) needed insulin to achieve the targets of blood glucose control. There were no differences in mean maternal age and birthweights. Fasting blood glucose levels were significantly higher in women with further need for insulin than those who only needed diet and exercise (p < 0.001). Also, blood glucose levels 2 h after the oral glucose intake were statistically different between the two groups (p 0.032). AUC for fasting glucose value was the highest according to ROC curve. Conclusions Fasting cutoff vales for 100 g oral glucose tolerance test are consistently higher in women diagnosed with Gestational Diabetes that further needed insulin to achieve adequate blood glucose control. The positive predictive value of fasting glucose value 105 mg/dl on OGTT was 81.1%, whereas for the cut-off 95 mg/dl it was 54.0%.

  3. Thermoluminescence response of flat optical fiber subjected to 9 MeV electron irradiations

    NASA Astrophysics Data System (ADS)

    Hashim, S.; Omar, S. S. Che; Ibrahim, S. A.; Hassan, W. M. S. Wan; Ung, N. M.; Mahdiraji, G. A.; Bradley, D. A.; Alzimami, K.

    2015-01-01

    We describe the efforts of finding a new thermoluminescent (TL) media using pure silica flat optical fiber (FF). The present study investigates the dose response, sensitivity, minimum detectable dose and glow curve of FF subjected to 9 MeV electron irradiations with various dose ranges from 0 Gy to 2.5 Gy. The above-mentioned TL properties of the FF are compared with commercially available TLD-100 rods. The TL measurements of the TL media exhibit a linear dose response over the delivered dose using a linear accelerator. We found that the sensitivity of TLD-100 is markedly 6 times greater than that of FF optical fiber. The minimum detectable dose was found to be 0.09 mGy for TLD-100 and 8.22 mGy for FF. Our work may contribute towards the development of a new dosimeter for personal monitoring purposes.

  4. Control of G1 arrest after DNA damage.

    PubMed Central

    Kastan, M B; Kuerbitz, S J

    1993-01-01

    The temporal relationship between DNA damage and DNA replication may be critical in determining whether the genetic changes necessary for cellular transformation occur after DNA damage. Recent characterization of the mechanisms responsible for alterations in cell-cycle progression after DNA damage in our laboratory have implicated the p53 (tumor suppressor) protein in the G1 arrest that occurs after certain types of DNA damage. In particular, we found that levels of p53 protein increased rapidly and transiently after nonlethal doses of gamma irradiation (XRT) in hematopoietic cells with wild-type, but not mutant, p53 genes. These changes in p53 protein levels were temporally linked to a transient G1 arrest in these cells. Hematopoietic cells with mutant or absent p53 genes did not exhibit this G1 arrest, through they continued to demonstrate a G2 arrest. We recently extended these observations of a tight correlation between the status of the endogenous p53 genes and this G1 arrest after XRT and this cell-cycle alteration after XRT was then established by transfecting cells lacking endogenous p53 genes with a wild-type gene and observing acquisition of the G1 arrest and by transfecting cells processing endogenous wild-type p53 genes with a mutant p53 gene and observing loss of the G1 arrest after XRT. These observations and their significance for our understanding of the mechanisms of DNA damage-induced cellular transformation are discussed. PMID:8013425

  5. Plasminogen activator inhibitor-1 5G/5G genotype is a protecting factor preventing posttransplant diabetes mellitus.

    PubMed

    Chang, Horng-Rong; Yang, Shun-Fa; Tsai, Jen-Pi; Hsieh, Ming-Chia; Wu, Sheng-Wen; Tsai, Hui-Ching; Hung, Tung-Wei; Huang, Jun-Huang; Lian, Jong-Da

    2011-01-30

    Plasminogen activator inhibitor 1 (PAI-1) is thought to play a role in the pathogenesis of obesity and insulin resistance. A connection between gestational diabetes mellitus and the functional -675 PAI-1 genotype has been reported. Therefore, we examined the role of the PAI-1 gene polymorphism in kidney transplant recipients. A total of 376 kidney transplant recipients were prospectively screened for posttransplant diabetes mellitus (PTDM). Eighty-one (21.5%) patients were diagnosed with PTDM and the other 295 patients were non-diabetic following kidney transplantation. DNA samples were isolated from the sera and analyzed for the functional -675 4G/5G promoter polymorphisms of the PAI-1 gene. Kidney transplant recipients with PTDM were significantly associated with tacrolimus use (p=0.03), older age (p=0.036), and higher body mass index (p=0.001). The genotype distribution was significantly different between the patients with PTDM (genotype 4G/4G:4G/5G:5G/5G=33.3%:60.5%:6.2%) and those without PTDM (genotype 4G/4G:4G/5G:5G/5G=36.9%:44.1%:19.0%) (p=0.018). Patients with homozygosity for 5G had a significantly lower rate of PTDM (aOR, 0.286, p=0.022) and higher cumulative event-free probability of time to PTDM (log rank test, p=0.0058). Homozygosity for the 5G allele of the PAI-1 gene constitutes a protecting factor for the development of PTDM. Our findings are similar to a previous study on gestational diabetes mellitus, and strongly support a possible genetic role of PAI-1 in the development of PTDM. Copyright © 2010 Elsevier B.V. All rights reserved.

  6. 4G/5G and A-844G Polymorphisms of Plasminogen Activator Inhibitor-1 Associated with Glioblastoma in Iran--a Case-Control Study.

    PubMed

    Pooyan, Honari; Ahmad, Ebrahimi; Azadeh, Rakhshan

    2015-01-01

    Glioblastoma is a highly aggressive and malignant brain tumor. Risk factors are largely unknown however, although several biomarkers have been identified which may support development, angiogenesis and invasion of tumor cells. One of these biomarkers is PAI-1. 4G/5G and A-844G are two common polymorphisms in the gene promotor of PAI 1 that may be related to high transcription and expression of this gene. Studies have shown that the prevalence of the 4G and 844G allele is significantly higher in patients with some cancers and genetic disorders. We here assessed the association of 4G/5G and A-844G polymorphisms with glioblastoma cancer risk in Iranians in a case-control study. All 71 patients with clinically confirmed and 140 volunteers with no history and symptoms of glioblastoma as control group were screened for 4G/5G and A-844G polymorphisms of PAI-1, using ARMS-PCR. Genotype and allele frequencies of case and control groups were analyzed using the DeFinetti program. Our results showed significant associations between 4G/5G (p=0.01824) and A-844G (p=0.02012) polymorphisms of the PAI-1 gene with glioblastoma cancer risk in our Iranian population. The results of this study supporting an association of the PAI-1 4G/5G (p=0.01824) and A-844G (p=0.02012) polymorphisms with increasing glioblastoma cancer risk in Iranian patients.

  7. 26 CFR 1.415(g)-1 - Disqualification of plans and trusts.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 5 2010-04-01 2010-04-01 false Disqualification of plans and trusts. 1.415(g)-1... Disqualification of plans and trusts. (a) Disqualification of plans—(1) In general. Under section 415(g) and this section, with respect to a particular limitation year, a plan (and the trust forming part of the plan) is...

  8. The Association of Plasminogen Activator Inhibitor Type 1 (PAI-1) Level and PAI-1 4G/5G Gene Polymorphism with the Formation and the Grade of Endometrial Cancer.

    PubMed

    Yıldırım, Malik Ejder; Karakuş, Savas; Kurtulgan, Hande Küçük; Kılıçgün, Hasan; Erşan, Serpil; Bakır, Sevtap

    2017-08-01

    Plasminogen activator inhibitor type 1 (PAI-1) is a serine protease inhibitor (Serpine 1), and it inhibits both tissue plasminogen activator and urokinase plasminogen activator which are important in fibrinolysis. We aimed to find whether there is a possible association between PAI-1 level, PAI-1 4G/5G polymorphism, and endometrial cancer. PAI-1 levels in peripheral blood were determined in 82 patients with endometrial carcinoma and 76 female healthy controls using an enzyme-linked immunoassay (ELISA). Then, the genomic DNA was extracted and screened by reverse hybridization procedure (Strip assay) to detect PAI 1 4G/5G polymorphism. The levels of PAI-1 in the patients were higher statistically in comparison to controls (P < 0.001). The distribution of PAI-1 4G/5G polymorphism was quite different between patients and controls (P = 0.008), and 4G allelic frequency was significantly higher in the patients of endometrial cancer than in controls (P = 0.026). We found significant difference between Grade 1 and Grade 2+3 patients in terms of the PAI-1 levels (P = 0.047). There was no association between PAI-1 4G/5G polymorphism and the grades of endometrial cancer (P = 0.993). Our data suggest that the level of PAI-1 and PAI-1 4G/5G gene polymorphism are effective in the formation of endometrial cancer. PAI-1 levels are also associated with the grades of endometrial cancer.

  9. High resolution mapping of the binding site on human IgG1 for Fc gamma RI, Fc gamma RII, Fc gamma RIII, and FcRn and design of IgG1 variants with improved binding to the Fc gamma R.

    PubMed

    Shields, R L; Namenuk, A K; Hong, K; Meng, Y G; Rae, J; Briggs, J; Xie, D; Lai, J; Stadlen, A; Li, B; Fox, J A; Presta, L G

    2001-03-02

    Immunoglobulin G (IgG) Fc receptors play a critical role in linking IgG antibody-mediated immune responses with cellular effector functions. A high resolution map of the binding site on human IgG1 for human Fc gamma RI, Fc gamma RIIA, Fc gamma RIIB, Fc gamma RIIIA, and FcRn receptors has been determined. A common set of IgG1 residues is involved in binding to all Fc gamma R; Fc gamma RII and Fc gamma RIII also utilize residues outside this common set. In addition to residues which, when altered, abrogated binding to one or more of the receptors, several residues were found that improved binding only to specific receptors or simultaneously improved binding to one type of receptor and reduced binding to another type. Select IgG1 variants with improved binding to Fc gamma RIIIA exhibited up to 100% enhancement in antibody-dependent cell cytotoxicity using human effector cells; these variants included changes at residues not found at the binding interface in the IgG/Fc gamma RIIIA co-crystal structure (Sondermann, P., Huber, R., Oosthuizen, V., and Jacob, U. (2000) Nature 406, 267-273). These engineered antibodies may have important implications for improving antibody therapeutic efficacy.

  10. Association between PAI-1 4G/5G polymorphism and diabetic nephropathy: a meta-analysis in the Chinese population.

    PubMed

    Gao, Wen-Feng; Guo, Ying-Bo; Bai, Yu; Ding, Xin-Yu; Yan, Yong-Ji; Wu, Zhen-Qi

    2016-09-01

    Although a number of studies have been conducted on the association between plasminogen activator inhibitor-1 (PAI-1) 4G/5G polymorphism and diabetic nephropathy (DN) in Chinese population, this association remains elusive and controversial. To further assess the effects of PAI-1 4G/5G polymorphism on the risk of DN, a meta-analysis was performed in the Chinese population. Relevant studies were identified using PubMed, Springer Link, Ovid, Chinese Wanfang Data Knowledge Service Platform, Chinese National Knowledge Infrastructure, and Chinese Biology Medicine through November, 2015. Pooled odds ratios (ORs) and 95 % confidence intervals (CIs) were used to assess the strength of the associations. This meta-analysis identified nine studies, including 777 DN cases, 413 healthy controls, and 523 DM controls. In the total analyses, a significantly elevated risk of DN was associated with variants of PAI-1 4G/5G when compared with the healthy group (4G vs. 5G, OR 2.46, 95 % CI 1.45-4.16; 4G/4G vs. 5G/5G, OR 4.32, 95 % CI 1.79-10.39; 4G/4G vs. 4G/5G +5G/5G, OR 2.96, 95 % CI 1.59-5.53; 4G/4G +4G/5G vs. 5G/5G, OR 2.78, 95 % CI 1.34-5.75) and DM group (4G vs. 5G, OR 1.93, 95 % CI 1.28-2.92; 4G/4G vs. 5G/5G, OR 2.99, 95 % CI 1.44-6.21; 4G/4G vs. 4G/5G +5G/5G, OR 2.84, 95 % CI 1.77-4.54). In the subgroup analyses stratified by ethnicity and geographic areas, it revealed the significant results in Chinese Han, in North and South China. This meta-analysis showed that the PAI-1 4G/4G variant, 4G allele might be risk alleles for DN susceptibility in the Chinese population, and further studies in other ethic groups are required for definite conclusions.

  11. Elevated Plasma Moxifloxacin Concentrations and SLCO1B1 g.−11187G>A Polymorphism in Adults with Pulmonary Tuberculosis

    PubMed Central

    Gelfond, Jon; Johnson-Pais, Teresa L.; Engle, Melissa; Peloquin, Charles A.; Johnson, John L.; Sizemore, Erin E.; Mac Kenzie, William R.

    2018-01-01

    ABSTRACT Moxifloxacin exhibits concentration-dependent prolongation of human QTc intervals and bactericidal activity against Mycobacterium tuberculosis. However, moxifloxacin plasma concentrations are variable between patients. We evaluated whether human gene polymorphisms affect moxifloxacin plasma concentrations in tuberculosis patients from two geographic regions. We enrolled a convenience sample of 49 adults with drug-sensitive pulmonary tuberculosis from Africa and the United States enrolled in two treatment trials of moxifloxacin as part of multidrug therapy. Pharmacokinetic parameters were evaluated by noncompartmental techniques. Human single-nucleotide polymorphisms of transporter genes were evaluated by analysis of covariance (ANCOVA) on moxifloxacin exposure and the peak (maximum) concentration (Cmax). The moxifloxacin area under the concentration-time curve from 0 to 24 h (AUC0–24) and Cmax were significantly increased by the drug milligram-per-kilogram dosage and the genotype of variant g.−11187G>A in the SLCO1B1 gene (rs4149015) but not by geographic region. The median moxifloxacin AUC0–24 was 46% higher and the median Cmax was 30% higher in 4 (8%) participants who had the SLCO1B1 g.−11187 AG genotype than in 45 participants who had the wild-type GG genotype (median AUC0–24 from the model, 34.4 versus 23.6 μg · h/ml [P = 0.005, ANCOVA]; median Cmax from the model, 3.5 versus 2.7 μg/ml [P = 0.009, ANCOVA]). Because moxifloxacin exhibits concentration-dependent prolongation of human QTc intervals and prolonged QTc intervals are associated with cardiac arrhythmia, further study is needed to evaluate the risk associated with the SLCO1B1 g.−11187G>A variant. (This study has been registered at ClinicalTrials.gov under identifier NCT00164463.) PMID:29463526

  12. 26 CFR 1.1502-100 - Corporations exempt from tax.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 12 2013-04-01 2013-04-01 false Corporations exempt from tax. 1.1502-100... Corporations exempt from tax. (a) In general—(1) Computation of tax liability. The tax liability for a consolidated return year of a group of two or more corporations described in section 1504(e) which are exempt...

  13. 26 CFR 1.1502-100 - Corporations exempt from tax.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 12 2012-04-01 2012-04-01 false Corporations exempt from tax. 1.1502-100... Corporations exempt from tax. (a) In general—(1) Computation of tax liability. The tax liability for a consolidated return year of a group of two or more corporations described in section 1504(e) which are exempt...

  14. 26 CFR 1.1502-100 - Corporations exempt from tax.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 12 2014-04-01 2014-04-01 false Corporations exempt from tax. 1.1502-100... Corporations exempt from tax. (a) In general—(1) Computation of tax liability. The tax liability for a consolidated return year of a group of two or more corporations described in section 1504(e) which are exempt...

  15. 26 CFR 1.1502-100 - Corporations exempt from tax.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 12 2011-04-01 2011-04-01 false Corporations exempt from tax. 1.1502-100... Corporations exempt from tax. (a) In general—(1) Computation of tax liability. The tax liability for a consolidated return year of a group of two or more corporations described in section 1504(e) which are exempt...

  16. SMART Digest™ compared with pellet digestion for analysis of human immunoglobulin G1 in rat serum by liquid chromatography tandem mass spectrometry.

    PubMed

    Lanshoeft, Christian; Heudi, Olivier; Cianférani, Sarah

    2016-05-15

    The newly developed SMART Digest™ kit was applied for the sample preparation of human immunoglobulin G1 (hIgG1) in rat serum prior to qualitative and quantitative analyses by liquid chromatography tandem mass spectrometry (LC-MS/MS). The sequence coverages obtained for the light and heavy chains of hIgG1A were 50 and 76%, respectively. The calibration curve was linear from 1.00 to 1000 μg/ml for three of four generic peptides. Overall, the SMART Digest™ kit resulted in similar quantitative data (linearity, sensitivity, accuracy, and precision) compared with the pellet digestion protocol. However, the SMART Digest™ required only 2 h of sample preparation with fewer reagents. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Upregulation of interleukin 7 receptor alpha and programmed death 1 marks an epitope-specific CD8+ T-cell response that disappears following primary Epstein-Barr virus infection.

    PubMed

    Sauce, Delphine; Larsen, Martin; Abbott, Rachel J M; Hislop, Andrew D; Leese, Alison M; Khan, Naeem; Papagno, Laura; Freeman, Gordon J; Rickinson, Alan B

    2009-09-01

    In immunocompetent individuals, the stability of the herpesvirus-host balance limits opportunities to study the disappearance of a virus-specific CD8(+) T-cell response. However, we noticed that in HLA-A 0201-positive infectious mononucleosis (IM) patients undergoing primary Epstein-Barr virus (EBV) infection, the initial CD8 response targets three EBV lytic antigen-derived epitopes, YVLDHLIVV (YVL), GLCTLVAML (GLC), and TLDYKPLSV (TLD), but only the YVL and GLC reactivities persist long-term; the TLD response disappears within 10 to 27 months. While present, TLD-specific cells remained largely indistinguishable from YVL and GLC reactivities in many phenotypic and functional respects but showed unique temporal changes in two markers of T-cell fate, interleukin 7 receptor alpha (IL-7Ralpha; CD127) and programmed death 1 (PD-1). Thus, following the antigen-driven downregulation of IL-7Ralpha seen on all populations in acute IM, in every case, the TLD-specific population recovered expression unusually quickly post-IM. As well, in four of six patients studied, TLD-specific cells showed very strong PD-1 upregulation in the last blood sample obtained before the cells' disappearance. Our data suggest that the disappearance of this individual epitope reactivity from an otherwise stable EBV-specific response (i) reflects a selective loss of cognate antigen restimulation (rather than of IL-7-dependent signals) and (ii) is immediately preceded, and perhaps mediated, by PD-1 upregulation to unprecedented levels.

  18. Magnetic removal of electron contamination for 60Co panoramic gamma ray exposure--Investigations with CaSO4:Dy and LiF based dosimeters.

    PubMed

    Kumar, Munish; Sahani, G; Chourasiya, G

    2010-06-01

    Electron contamination from a sealed (60)Co radiation source has been investigated comprehensively using a CaSO(4):Dy based TLD badge and LiF crystals. It has been found that due to electron contamination, the thermoluminescence (TL) detectors exhibit over response which can be corrected by applying a magnetic field. It has also been found that for a source-to-dosimeter distance of 50 cm, the ratio of the TL readouts of the third to first discs of the TLD badge reduces from approximately 1.5 to approximately 1.00 after applying a magnetic field. Hence detectors which are sensitive to electrons as well as photons, and are capable of distinguishing them, can lead to an erroneous measurement. This happens because the contribution due to electron contamination interferes with pure gamma calibration. The study is helpful in establishing accurate calibration and appropriate correction factors for personnel monitoring carried out using CaSO(4):Dy based TLD badge. Copyright 2009 Elsevier Ltd. All rights reserved.

  19. Body Weight Gain During a Discrete Nursing Episode in Suckling Rats Reared at 1.5-g or 1.5-g Exceeds that of 1.0-g Controls and is Independent of Material Hypergravity Exposure

    NASA Technical Reports Server (NTRS)

    Ronca, April E.; Baer, Lisa A.; Plaut, Karen; Wade, Charles E.; Sun, Sid (Technical Monitor)

    2001-01-01

    We recently reported that body weights of suckling rats reared during 1.5-g centrifugation are approximately 10% lower than those of 1.0-g controls. This finding raises the possibility that hypergravity exposed pups ingest less milk than controls due to either impairments in their ability to acquire milk from the nipple, or to decreased availability or palatability of their mother's milk. In the present study, we analyzed body weight gain in suckling rats reared during a discrete nursing episode following rearing at either 1.75-g, 1.5-g or 1.0-g. On Gestational day (G) 10 of the rats' 22-day pregnancy, time-bred SD rat dams were 1:1 matched based on body weight and assigned to either Hypergravity (HG) or Stationary Yoked Control (SYC) conditions and to either 1.75-g or 1.5-g conditions. Beginning on G11, HG dams and litters were exposed to 26 days of continuous centrifugation with brief daily stops for veterinary inspection and animal maintenance. On the day following birth (Postnatal day), litters were pooled within each condition then randomly re-assigned in equivalent proportions to HG and SYC dams. On P15, HG litters were removed from their mother's and placed in an incubator (33 C). Following a 4hr deprivation period, four neonates were tested from each litter, with two pups placed with either their own dam or the SYC dam; two pups from the yoked mother were paired with the HG pups. Pups were individually weighed, permitted to suckle for 75 min, then re-weighed. At the start of the test, the body weights of HG pups were significantly less than those of SYC pups (p less than 0.05). Relative to SYC pups, BG pups showed significantly greater proportional body weight gain (p less than 0.05), possibly due to augmented post-centrifugation feeding. Pup weight gain was independent of maternal hypergravity exposure. Neither impairments in milk acquisition nor milk availability or palatibility of hypergravity-exposed dams cannot account for reduced body mass of

  20. ABCB1 regulation through LRPPRC is influenced by the methylation status of the GC -100 box in its promoter

    PubMed Central

    Corrêa, Stephany; Binato, Renata; Du Rocher, Bárbara; Ferreira, Gerson; Cappelletti, Paola; Soares-Lima, Sheila; Pinto, Luis Felipe; Mencalha, André; Abdelhay, Eliana

    2014-01-01

    One of the potential mechanisms of imatinib mesylate (IM) resistance in chronic myeloid leukemia (CML) is increased level of P-glycoprotein (Pgp). Pgp is an efflux pump capable of activating the multidrug resistance (MDR) phenotype. The gene encoding Pgp (ABCB1) has several binding sites in its promoter region, along with CpG islands and GC boxes, involved in its epigenetic control. In previous work, we performed a proteomic study to identify proteins involved in IM cross-resistance in acute leukemia. Among these proteins, we identified LRPPRC as a potential regulator of ABCB1 transcription via an invMED1 binding site in ABCB1. Interestingly, this invMED1 binding site overlaps with the GC -100 box. In this work, we investigated the potential role of LRPPRC in the regulation of ABCB1 transcriptional activity in CML resistance. In addition, we evaluated the potential connection between this regulation and the methylation status of the ABCB1 promoter in its GC -100 box. Our results show that LRPPRC binds prominently to the ABCB1 promoter in Lucena cells, an IM-resistant cell line. Luciferase assays showed that ABCB1 transcription is positively regulated by LRPPRC upon its knockdown. Pyrosequencing analysis showed that the ABCB1 promoter is differentially methylated at its GC -100 box in K562 cells compared with Lucena cells, and in CML patients with different response to IM. Chromatin immunoprecipitation and Pgp expression after DNA demethylation treatment showed that LRPPRC binding is affected by the methylation status of ABCB1 GC -100 box. Taken together, our findings indicate that LRPPRC is a transcription factor related to ABCB1 expression and highlight the importance of epigenetic regulation in CML resistance. PMID:25089713

  1. ABCB1 regulation through LRPPRC is influenced by the methylation status of the GC -100 box in its promoter.

    PubMed

    Corrêa, Stephany; Binato, Renata; Du Rocher, Bárbara; Ferreira, Gerson; Cappelletti, Paola; Soares-Lima, Sheila; Pinto, Luis Felipe; Mencalha, André; Abdelhay, Eliana

    2014-08-01

    One of the potential mechanisms of imatinib mesylate (IM) resistance in chronic myeloid leukemia (CML) is increased level of P-glycoprotein (Pgp). Pgp is an efflux pump capable of activating the multidrug resistance (MDR) phenotype. The gene encoding Pgp (ABCB1) has several binding sites in its promoter region, along with CpG islands and GC boxes, involved in its epigenetic control. In previous work, we performed a proteomic study to identify proteins involved in IM cross-resistance in acute leukemia. Among these proteins, we identified LRPPRC as a potential regulator of ABCB1 transcription via an invMED1 binding site in ABCB1. Interestingly, this invMED1 binding site overlaps with the GC -100 box. In this work, we investigated the potential role of LRPPRC in the regulation of ABCB1 transcriptional activity in CML resistance. In addition, we evaluated the potential connection between this regulation and the methylation status of the ABCB1 promoter in its GC -100 box. Our results show that LRPPRC binds prominently to the ABCB1 promoter in Lucena cells, an IM-resistant cell line. Luciferase assays showed that ABCB1 transcription is positively regulated by LRPPRC upon its knockdown. Pyrosequencing analysis showed that the ABCB1 promoter is differentially methylated at its GC -100 box in K562 cells compared with Lucena cells, and in CML patients with different response to IM. Chromatin immunoprecipitation and Pgp expression after DNA demethylation treatment showed that LRPPRC binding is affected by the methylation status of ABCB1 GC -100 box. Taken together, our findings indicate that LRPPRC is a transcription factor related to ABCB1 expression and highlight the importance of epigenetic regulation in CML resistance.

  2. Geologic map of the Richland 1:100,000 quadrangle, Washington

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Reidel, S.P.; Fecht, K.R.

    1993-09-01

    This map of the Richland 1:100,000-scale quadrangle, Washington, shows the geology of one of fifteen complete or partial 1:100,000-scale quadrangles that cover the southeast quadrant of Washington. Geologic maps of these quadrangles have been compiled by geologists with the Washington Division of Geology and Earth Resources (DGER) and Washington State University and are the principal data sources for a 1:250,000-scale geologic map of the southeast quadrant of Washington, which is in preparation. Eleven of these quadrangles are being released as DGER open-file reports. The map of the Wenatchee quadrangle has been published by the US Geological Survey, and the Mosesmore » Lake, Ritzville quadrangles have already been released.« less

  3. In neonates S100A8/S100A9 alarmins prevent the expansion of a specific inflammatory monocyte population promoting septic shock.

    PubMed

    Heinemann, Anna S; Pirr, Sabine; Fehlhaber, Beate; Mellinger, Lara; Burgmann, Johanna; Busse, Mandy; Ginzel, Marco; Friesenhagen, Judith; von Köckritz-Blickwede, Maren; Ulas, Thomas; von Kaisenberg, Constantin S; Roth, Johannes; Vogl, Thomas; Viemann, Dorothee

    2017-03-01

    The high susceptibility of newborn infants to sepsis is ascribed to an immaturity of the neonatal immune system, but the molecular mechanisms remain unclear. Newborn monocytes massively release the alarmins S100A8/S100A9. In adults, these are major regulators of immunosuppressive myeloid-derived suppressor cells (MDSCs). We investigated whether S100A8/S100A9 cause an expansion of monocytic MDSCs (Mo-MDSCs) in neonates, thereby contributing to an immunocompromised state. Mo-MDSCs have been assigned to CD14 + /human leukocyte antigen (HLA)-DR - /low /CD33 + monocytes in humans and to CD11b + /Gr-1 int /Ly6G - /Ly6C hi cells in mice. We found monocytes with these phenotypes significantly expanded in their respective newborns. Functionally, however, they did not prove immunosuppressive but rather responded inflammatorily to microbial stimulation. Their expansion did not correlate with high S100A8/S100A9 levels in cord blood. Murine studies revealed an excessive expansion of CD11b + /Gr-1 int /Ly6G - /Ly6C hi monocytes in S100A9 -/- neonates compared to wild-type neonates. This strong baseline expansion was associated with hyperinflammatory responses during endotoxemia and fatal septic courses. Treating S100A9 -/- neonates directly after birth with S100A8/S100A9 alarmins prevented excessive expansion of this inflammatory monocyte population and death from septic shock. Our data suggest that a specific population of inflammatory monocytes promotes fatal courses of sepsis in neonates if its expansion is not regulated by S100A8/S100A9 alarmins.-Heinemann, A. S., Pirr, S., Fehlhaber, B., Mellinger, L., Burgmann, J., Busse, M., Ginzel, M., Friesenhagen, J., von Köckritz-Blickwede, M., Ulas, T., von Kaisenberg, C. S., Roth, J., Vogl, T., Viemann, D. In neonates S100A8/S100A9 alarmins prevent the expansion of a specific inflammatory monocyte population promoting septic shock. © FASEB.

  4. Upregulation of Interleukin 7 Receptor Alpha and Programmed Death 1 Marks an Epitope-Specific CD8+ T-Cell Response That Disappears following Primary Epstein-Barr Virus Infection▿ †

    PubMed Central

    Sauce, Delphine; Larsen, Martin; Abbott, Rachel J. M.; Hislop, Andrew D.; Leese, Alison M.; Khan, Naeem; Papagno, Laura; Freeman, Gordon J.; Rickinson, Alan B.

    2009-01-01

    In immunocompetent individuals, the stability of the herpesvirus-host balance limits opportunities to study the disappearance of a virus-specific CD8+ T-cell response. However, we noticed that in HLA-A*0201-positive infectious mononucleosis (IM) patients undergoing primary Epstein-Barr virus (EBV) infection, the initial CD8 response targets three EBV lytic antigen-derived epitopes, YVLDHLIVV (YVL), GLCTLVAML (GLC), and TLDYKPLSV (TLD), but only the YVL and GLC reactivities persist long-term; the TLD response disappears within 10 to 27 months. While present, TLD-specific cells remained largely indistinguishable from YVL and GLC reactivities in many phenotypic and functional respects but showed unique temporal changes in two markers of T-cell fate, interleukin 7 receptor alpha (IL-7Rα; CD127) and programmed death 1 (PD-1). Thus, following the antigen-driven downregulation of IL-7Rα seen on all populations in acute IM, in every case, the TLD-specific population recovered expression unusually quickly post-IM. As well, in four of six patients studied, TLD-specific cells showed very strong PD-1 upregulation in the last blood sample obtained before the cells’ disappearance. Our data suggest that the disappearance of this individual epitope reactivity from an otherwise stable EBV-specific response (i) reflects a selective loss of cognate antigen restimulation (rather than of IL-7-dependent signals) and (ii) is immediately preceded, and perhaps mediated, by PD-1 upregulation to unprecedented levels. PMID:19605492

  5. SU-G-TeP2-12: IROCHouston and MDAPL SRS Anthropomorphic Phantom Results

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molineu, A; Kry, S; Alvarez, P

    Purpose: To report the results of SRS phantom irradiations Methods: Anthropomorphic SRS head phantoms were sent to institutions participating in NCI sponsored SRS clinical trials and institutions interested in verifying SRS treatment delivery. The phantom shell was purchased from Phantom Laboratory and altered to house dosimetry and imaging inserts. The imaging insert has 1.9 cm diameter spherical target. The dosimetry insert holds two TLD capsules and radiochromic film in the coronal and sagittal planes through the center of the target. Institutions were asked to image, plan and treat the phantom as they would an SRS patient. GammaKnife, CyberKnife and c-armmore » accelerator institutions were asked to cover the target with 15 Gy, 20 Gy and 25 Gy, respectively. Following these guidelines and typical planning protocols for these three types of machines gives roughly 30 Gy to the center of the target for all units. Submission of the DICOM digital data set was required for analysis. Criteria of 5% for TLD results and 85% of pixels passing 5%/3mm gamma analysis were applied beginning in 2013. Results: The phantom was analyzed 269 times between the beginning of 2013 to present. The pass rate is 81%. Nineteen of the irradiation results failed only the TLD criteria, 19 failed only the film criteria and 12 failed both. Irradiations included 32 CyberKnife 23 GammaKnife, 3 TomoTherapy and 211 c-arm units. Planning systems included Eclipse, Ergo, GammaPlan, Hi-Art, iPlan, Monaco, MultiPlan, Pinnacle, RayStation, XiO and XKnife. Irradiations that were not accompanied with DICOM data were not included in this analysis. Conclusion: The phantom is a valuable end-to-end test used to independently verify the accuracy of SRS treatment delivery. This investigation was supported by IROC grant CA180803 awarded by the NCI.« less

  6. Distances to supernova remnants G20.4 + 0.1, G24.7 - 0.6, and G28.6 - 0.1 and new molecular cloud associations

    NASA Astrophysics Data System (ADS)

    Ranasinghe, S.; Leahy, D. A.

    2018-06-01

    Accurate distances to supernova remnants (SNRs) are crucial in determining their size, age, luminosity, and evolutionary state. To determine distances, we chose three SNRs from the VLA (Very Large Array) Galactic Plane Survey for extraction of H I absorption spectra. Analysing H I absorption spectra, 13CO emission spectra, and H I and 13CO channel maps, kinematic velocities (or their limits) to the three SNRs were calculated. The three SNRs are probably associated with molecular clouds and the new distance to G20.4 + 0.1, G24.7 - 0.6, and G28.6 - 0.1 are 7.8 ± 0.5 kpc, 3.8 ± 0.2 kpc, and 9.6 ± 0.3 kpc, respectively.

  7. The prevalence of 4G/5G polymorphism of plasminogen activator inhibitor-1 (PAI-1) gene in central serous chorioretinopathy and its association with plasma PAI-1 levels.

    PubMed

    Sogutlu Sari, Esin; Yazici, Alper; Eser, Betül; Erol, Muhammet Kazim; Kilic, Adil; Ermis, Sitki Samet; Koytak, Arif; Akşit, Hasan; Yakut, Tahsin

    2014-12-01

    Central serous chorioretinopathy (CSCR) is a poorly understood disease and the choroidal circulation abnormality induced by the plasminogen activator inhibitor type 1 (PAI-1) seems to be associated with the pathogenesis. There are many reports indicating that 4 G/5 G polymorphism of the PAI-1 gene is a risk factor for several diseases related to the elevated serum levels of PAI-1. To evaluate the 4 G/5 G polymorphism of the PAI-1 gene and its association with serum levels of PAI-1 in acute CSCR patients. Sixty CSCR patients and 50 healthy control patients were included. The PAI-1 4 G/5 G was genotyped using the polymerase chain reaction-restriction technique. Serum PAI-1 level was measured using enzyme-linked immunosorbent assay. Demographic data consisting of age, sex, body mass index (BMI) as well as genotype disturbances and serum PAI-1 levels were compared between the groups. Statistical significance for differences in the serum PAI-1 levels of each group with different genotypes was also analyzed. The CSCR group consisted of 40 male (66.7%) and 20 female (33.3%) patients with a mean age of 46.7 ± 8.39 years. The control group consisted of 32 male (64%) and 18 female (36%) healthy subjects with a mean age of 45.8 ± 8.39 years. There was no statistically significant difference between the groups in terms of age, sex and BMI. In the CSCR group the genotype frequencies were 4 G/4G: 30% (n = 18), 4G/5 G: 50% (n = 30), 5 G/5G: 20% (n = 12) and in the control group genotype frequencies were 34% (n = 17), 42% (n = 21) and 24% (n = 12), respectively. There was no statistically significant difference in the distribution of genotypes among the groups (chi-squared, p = 0.70). The CSCR group had a significantly higher serum PAI-1 concentration than the control group (p = 0.001). In both groups the mean plasma PAI-1 concentration did not vary significantly among the different genotypes (p > 0.05). Although our results demonstrated that the patients with acute CSCR have

  8. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    NASA Astrophysics Data System (ADS)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  9. 26 CFR 1.904(g)-1 - Overall domestic loss and the overall domestic loss account.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... loss account. 1.904(g)-1 Section 1.904(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF... the United States § 1.904(g)-1 Overall domestic loss and the overall domestic loss account. (a... accounts for purposes of section 904(g). Section 1.904(g)-2 provides rules for recapturing the balance in...

  10. 26 CFR 1.904(g)-1 - Overall domestic loss and the overall domestic loss account.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... loss account. 1.904(g)-1 Section 1.904(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF... the United States § 1.904(g)-1 Overall domestic loss and the overall domestic loss account. (a... accounts for purposes of section 904(g). Section 1.904(g)-2 provides rules for recapturing the balance in...

  11. The influence of monovalent cations on trimeric G protein G(i)1α activity in HEK293 cells stably expressing DOR-G(i)1α (Cys(351)-Ile(351)) fusion protein.

    PubMed

    Vošahlíková, M; Svoboda, P

    2011-01-01

    The effect of monovalent cations on trimeric G protein G(i)1α was measured at equimolar concentration of chloride anion in pertussis-toxin (PTX)-treated HEK293 cells stably expressing PTX-insensitive DOR- G(i)1α (Cys(351)-Ile(351)) fusion protein by high-affinity [(35)S]GTPgammaS binding assay. The high basal level of binding was detected in absence of DOR agonist and monovalent ions and this high level was inhibited with the order of: Na(+) > K(+) > Li(+). The first significant inhibition was detected at 1 mM NaCl. The inhibition by monovalent ions was reversed by increasing concentrations of DOR agonist DADLE. The maximum DADLE response was also highest for sodium and decreased in the order of: Na(+) > K(+) ~ Li(+). Our data indicate i) an inherently high activity of trimeric G protein G(i)1α when expressed within DOR- G(i)1α fusion protein and determined in the absence of monovalent cations, ii) preferential sensitivity of DOR- G(i)1alpha to sodium as far as maximum of agonist response is involved.

  12. The protein source in embryo culture media influences birthweight: a comparative study between G1 v5 and G1-PLUS v5.

    PubMed

    Zhu, Jinliang; Li, Ming; Chen, Lixue; Liu, Ping; Qiao, Jie

    2014-07-01

    Does protein source or human serum albumin (HSA) in embryo culture media influence the subsequent birthweight? A significant difference was observed in gestational age- and gender-adjusted birthweight (Z scores) and the proportion of large-for-gestational age (LGA) babies between embryos cultured in G1 v5 and those cultured in G1-PLUS v5 media. It has been reported that the birthweights of singletons born from embryos cultured in Vitrolife are significantly higher than those cultured in the Cook group of media, and that G1-PLUS (Vitrolife, Gothenburg, Sweden) is associated with increased birth and placenta weights compared with Medicult ISMI. This study was a retrospective analysis of neonatal birthweights, and included 1097 singletons born from fresh embryo transfer cycles at the Center for Reproductive Medicine of Peking University Third Hospital between January 2011 and August 2012. The number of singletons born from G1 v5 culture media was 489, and the number of singletons born from G1-PLUS v5 media was 608. Patients <40 years of age with a BMI <30 kg/m² were analysed. Only data from newborns from singleton pregnancies and born alive after the 28th week of gestation were included. Patients with a vanishing twin or with pregnancy-related complications, such as diabetes and hypertension, were excluded, as were patients who received preimplantation genetic diagnosis or used donor oocytes. Multiple linear regression analysis was performed to determine the influence of individual factors on birthweights of singleton newborns. The birthweights and Z scores of singletons and LGA babies were compared between the G1 v5 and G1-PLUS v5 media groups. The absolute birthweights for singletons resulting from G1-PLUS v5 were not different from singletons resulting from G1 v5 (3375.9 ± 479.6 g versus 3333.2 ± 491.6 g, respectively; P = 0.14). However the Z scores for singletons from embryos cultured in G1-PLUS v5 were significantly higher than for singletons cultured in G1 v

  13. Clinicopathological significance of plasminogen activator inhibitor-1 promoter 4G/5G polymorphism in breast cancer: a meta-analysis.

    PubMed

    Lee, Ju-Han; Kim, Younghye; Choi, Jung-Woo; Kim, Young-Sik

    2013-01-01

    Plasminogen activator inhibitor type 1 (PAI-1) is associated with poor prognosis in breast cancer. Transcriptional expression of the PAI-1 can be controlled by PAI-1 promoter 4G/5G polymorphism. However, the significance of PAI-1 promoter 4G/5G polymorphism in breast cancer patients is contentious. To address this controversy, we conducted a meta-analysis for the relationships between PAI-1 promoter polymorphism and clinicopathological characteristics of breast cancer. Relevant published studies were identified using a search of PubMed, Embase, and the ISI Web of Science. The effect sizes of PAI-1 promoter 4G/5G polymorphism on breast cancer risk, lymph node metastasis, histologic grade, and overall survival were calculated by odds ratio (OR) or hazard ratio. The effect sizes were combined using a random-effects model. Individuals with 4G/4G genotype had a higher risk of breast cancer than those with the combined 4G/5G and 5G/5G genotypes (OR = 1.388; p = 0.031). Breast cancer patients with the 5G/5G genotype displayed lymph node metastasis more than patients with either the combined other genotypes (OR = 1.495; p = 0.027) or with the 4G/4G genotype (OR = 1.623; p = 0.018). However, the PAI-1 promoter 4G/5G polymorphism was not associated with histological grade or overall survival. PAI-1 promoter 4G/5G polymorphism is associated with a relatively increased risk of breast cancer development and lymph node metastasis. Copyright © 2013 IMSS. Published by Elsevier Inc. All rights reserved.

  14. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 26 Internal Revenue 18 2011-04-01 2011-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  15. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 26 Internal Revenue 18 2010-04-01 2010-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  16. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 26 Internal Revenue 18 2014-04-01 2014-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  17. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 26 Internal Revenue 18 2013-04-01 2013-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  18. 26 CFR 301.6503(g)-1 - Suspension pending correction.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 26 Internal Revenue 18 2012-04-01 2012-04-01 false Suspension pending correction. 301.6503(g)-1 Section 301.6503(g)-1 Internal Revenue INTERNAL REVENUE SERVICE, DEPARTMENT OF THE TREASURY (CONTINUED... Collection § 301.6503(g)-1 Suspension pending correction. The running of the periods of limitations provided...

  19. The Proteolytic Fraction from Latex of Vasconcellea cundinamarcensis (P1G10) Enhances Wound Healing of Diabetic Foot Ulcers: A Double-Blind Randomized Pilot Study.

    PubMed

    Tonaco, Luís A B; Gomes, Flavia L; Velasquez-Melendez, Gustavo; Lopes, Miriam T P; Salas, Carlos E

    2018-04-01

    The aim of the study was to investigate the role of the proteolytic fraction from Vasconcellea cundinamarcensis, designated as P1G10, on the healing of chronic foot ulcers in neuropathic patients with diabetes 2. Fifty patients were enrolled in a prospective, randomized, double-blind trial, to verify the efficacy and safety of a topical dressing formulated with 0.1% P1G10, intended for wound healing, versus a hydrogel (control) protocol. Upon completion of the intervention, the outcome evaluated the number of patients attaining full epithelization (100%), or at least 80% healing. Statistical analysis compared the data on each group for the significance of the differences. Collection of data was finished in week 16, and the results were analyzed by intention to treat. The results showed that, in the control group, 5 patients attained 100% ulcer healing, 3 patients ≥ 80% healing and 11 experienced ulcer changes ≤ 80%, and the remainder showed no changes or their wounds became worse. Meanwhile, in the P1G10 group, 11 patients experienced full healing, 4 had healing ≥ 80% and 5 had ulcer changes ≤ lower than 80%, and the remainder showed no changes or their wounds became worse. The healing incidence for the first endpoint (100% healing) showed that the P1G10 group was 2.95-fold more efficacious than the control group (CI 95%) and 2.52-fold (CI, 95%) higher than its control for the second endpoint (80% healing). These data support the hypothesis that topical application of the proteolytic fraction identified as P1G10 significantly enhances foot ulcer healing compared to hydrogel treatment.

  20. PAI-1 expression and its regulation by promoter 4G/5G polymorphism in clear cell renal cell carcinoma.

    PubMed

    Choi, Jung-Woo; Lee, Ju-Han; Park, Hong Seok; Kim, Young-Sik

    2011-10-01

    To characterise patients with high plasminogen activator inhibitor-1 (PAI-1) expression as oral PAI-1 antagonists are currently in preclinical trials, and to determine whether the PAI-1 promoter 4G/5G polymorphism regulates PAI-1 expression in clear cell renal cell carcinoma (CCRCC). PAI-1 expression was examined by immunohistochemistry in 69 CCRCC specimens. In addition, the promoter 4G/5G polymorphism was investigated by both allele-specific PCR and direct DNA sequencing. PAI-1 was overexpressed in 25/69 (36.2%) patients with CCRCC. PAI-1 staining was intense in tumour cells with a high Fuhrman nuclear grade and in spindle-shaped tumour cells. PAI-1 expression was significantly associated with older age at diagnosis (p=0.027), high nuclear grade (p<0.001), advanced clinical stage (p=0.030) and distant metastasis (p=0.009). In survival analyses, PAI-1 expression was correlated with disease-free survival in Kaplan-Meier curves (p=0.015) but was not significant in the Cox hazards model (p=0.527). The frequencies of the promoter polymorphism were 24.6% (17/69) 4G/4G, 43.5% (30/69) 4G/5G and 31.9% (22/69) 5G/5G. The homozygous 4G/4G or 5G/5G group showed a tendency for a high nuclear grade (p=0.05) but the 4G/5G polymorphism was not related to other prognostic parameters. PAI-1 expression was poorly correlated with its promoter 4G/5G polymorphism (Spearman ρ=0.088). CCRCC with high PAI-1 expression is characterised by older age, high nuclear grade, advanced stage, distant metastasis and/or shortened disease-free survival. PAI-1 expression is not affected by the promoter 4G/5G polymorphism.