Sample records for tcab initiative led

  1. An Activity Switch in Human Telomerase Based on RNA Conformation and Shaped by TCAB1.

    PubMed

    Chen, Lu; Roake, Caitlin M; Freund, Adam; Batista, Pedro J; Tian, Siqi; Yin, Yi A; Gajera, Chandresh R; Lin, Shengda; Lee, Byron; Pech, Matthew F; Venteicher, Andrew S; Das, Rhiju; Chang, Howard Y; Artandi, Steven E

    2018-05-18

    Ribonucleoprotein enzymes require dynamic conformations of their RNA constituents for regulated catalysis. Human telomerase employs a non-coding RNA (hTR) with a bipartite arrangement of domains-a template-containing core and a distal three-way junction (CR4/5) that stimulates catalysis through unknown means. Here, we show that telomerase activity unexpectedly depends upon the holoenzyme protein TCAB1, which in turn controls conformation of CR4/5. Cells lacking TCAB1 exhibit a marked reduction in telomerase catalysis without affecting enzyme assembly. Instead, TCAB1 inactivation causes unfolding of CR4/5 helices that are required for catalysis and for association with the telomerase reverse-transcriptase (TERT). CR4/5 mutations derived from patients with telomere biology disorders provoke defects in catalysis and TERT binding similar to TCAB1 inactivation. These findings reveal a conformational "activity switch" in human telomerase RNA controlling catalysis and TERT engagement. The identification of two discrete catalytic states for telomerase suggests an intramolecular means for controlling telomerase in cancers and progenitor cells. Copyright © 2018 Elsevier Inc. All rights reserved.

  2. The effect of transforming care at the bedside initiative on healthcare teams' work environments.

    PubMed

    Lavoie-Tremblay, Mélanie; O'Conner, Patricia; Harripaul, Anastasia; Biron, Alain; Ritchie, Judith; Lavigne, Genevieve L; Baillargeon, Sophie; Ringer, Justin; Macgibbon, Brenda; Taylor-Ducharme, Sharon; Sourdif, Jacynthe

    2014-02-01

    Different initiatives have been implemented in healthcare organizations to improve efficiency, such as transforming care at the bedside (TCAB). However, there are important gaps in understanding the effect of TCAB on healthcare teams' work environments. The specific aim of the study is to describe findings regarding the TCAB initiative effects on healthcare teams' work environments. A pretest and posttest study design was used for this study. The TCAB initiative was implemented in fall 2010 in a university health center in Montreal, Canada. The sample consisted of healthcare workers from four different care units. Statistically significant improvement was observed with the communicating specific information subscale from the measure of processes of care variable, and a significant difference was found between the support from colleagues variable, which was higher at baseline than postprogram. The differences for psychological demand, decisional latitude, and effort-reward were not significant. TCAB is an intervention that allows healthcare teams to implement change to improve patients' and families' outcomes. Ongoing energy should focus on how to improve communication among all members of the team and ensure their support. © 2013 Sigma Theta Tau International.

  3. High-use supplies at the bedside.

    PubMed

    Stefancyk, Amanda L

    2009-02-01

    This is the sixth in a series of articles from Massachusetts General Hospital in Boston describing one general medical unit's experiences with Transforming Care at the Bedside (TCAB). An initiative begun by the Robert Wood Johnson Foundation (RWJF) and the Institute for Healthcare Improvement, TCAB was developed as a way to improve care on medical-surgical units, patients' and family members' experience of care, and teamwork among care team members and to increase nurse satisfaction and retention. The TCAB philosophy engages all care leaders, but empowers bedside nurses to generate ideas and solutions for change. Mass General is one of 68 hospitals participating in a two-year TCAB initiative led by the American Organization of Nurse Executives and funded with a grant from the RWJF. For more information on TCAB, go to www.rwjf.org/pr/product.jsp?id=31512.

  4. Improving processes of care: making changes that hit and miss.

    PubMed

    Stefancyk, Amanda L

    2009-06-01

    This is the 10th in a series of articles from Massachusetts General Hospital in Boston describing one general medical unit's experiences with Transforming Care at the Bedside (TCAB). An initiative begun by the Robert Wood Johnson Foundation (RWJF) and the Institute for Healthcare Improvement, TCAB was developed as a way to improve care on medical-surgical units, patients' and family members' experience of care, and teamwork among care team members and to increase nurse satisfaction and retention. Mass General is one of 68 hospitals participating in a two-year TCAB initiative led by the American Organization of Nurse Executives and funded with a grant from the RWJF. For more information on TCAB, go to www.rwjf.org/pr/product.jsp?id=31512.

  5. The Four-Tier Continuum of Academic and Behavioral Support (4T-CABS) Model: An Integrated Model for Medical Student Success.

    PubMed

    Stegers-Jager, Karen M; Cohen-Schotanus, Janke; Themmen, Axel P N

    2017-11-01

    Not all students cope successfully with the demands of medical school, and students' struggles may result in study delay or dropout. To prevent these outcomes, medical schools need to identify students who are experiencing academic difficul ties and provide them with timely interventions through access to support programs. Although the importance of early identification and intervention is well recognized, less is known about successful strategies for identifying and supporting struggling students.Building on the literature and their own empirical findings, the authors propose an integrated, school-wide model for medical student success comprising a continuum of academic and behavioral support. This Four-Tier Continuum of Academic and Behavioral Support (4T-CABS) model focuses on improving both academic and behavioral outcomes by offering support for students at four levels, which range from adequate instruction for all, to targeted small-group interventions, to individualized support, and also include exit support for students who might be better off in another degree program. Additionally, medical schools should provide both academic and behavioral support; set high, yet realistic expectations and clearly communicate these to students; and intervene early, which requires timely identification of at-risk students who would benefit from the different types and tiers of support. Finally, interventions should be evidence based and fit the needs of the identified groups of students. The authors argue that adopting the core principles of the 4T-CABS model will enable medical schools to maximize academic engagement and performance for all students.

  6. Community engagement on the Thai–Burmese border: rationale, experience and lessons learnt

    PubMed Central

    Cheah, Phaik Yeong; Lwin, Khin Maung; Phaiphun, Lucy; Maelankiri, Ladda; Parker, Michael; Day, Nicholas P.; White, Nicholas J.; Nosten, François

    2012-01-01

    Community engagement is increasingly promoted in developing countries, especially in international health research, but there is little published experience. The Shoklo Malaria Research Unit (SMRU) conducts research with refugees, migrant workers, displaced people, and day migrants on the Thai-Burmese border, and has recently facilitated the set up of the Tak Province Border Community Ethics Advisory Board (T-CAB). Valuable lessons have been learnt from consultation with the T-CAB especially in the area of participant recruitment and the informed consent process. A lot of new research questions have emerged from consultation with the T-CAB. This paper describes our experience, lessons learnt and the unique challenges faced working with the T-CAB from its initial conception to date. We conclude that consultation with the T-CAB has made improvements in our research in particular operational and ethical aspects of our studies. PMID:22984375

  7. Engaging Frontline Staff in Performance Improvement: The American Organization of Nurse Executives Implementation of Transforming Care at the Bedside Collaborative.

    PubMed

    Needleman, Jack; Pearson, Marjorie L; Upenieks, Valda V; Yee, Tracy; Wolstein, Joelle; Parkerton, Melissa

    2016-02-01

    Process improvement stresses the importance of engaging frontline staff in implementing new processes and methods. Yet questions remain on how to incorporate these activities into the workday of hospital staff or how to create and maintain its commitment. In a 15-month American Organization of Nurse Executives collaborative involving frontline medical/surgical staff from 67 hospitals, Transforming Care at the Bedside (TCAB) was evaluated to assess whether participating units successfully implemented recommended change processes, engaged staff, implemented innovations, and generated support from hospital leadership and staff. In a mixed-methods analysis, multiple data sources, including leader surveys, unit staff surveys, administrative data, time study data, and collaborative documents were used. All units reported establishing unit-based teams, of which >90% succeeded in conducting tests of change, with unit staff selecting topics and making decisions on adoption. Fifty-five percent of unit staff reported participating in unit meetings, and 64%, in tests of change. Unit managers reported substantial increase in staff support for the initiative. An average 36 tests of change were conducted per unit, with 46% of tested innovations sustained, and 20% spread to other units. Some 95% of managers and 97% of chief nursing officers believed that the program had made unit staff more likely to initiate change. Among staff, 83% would encourage adoption of the initiative. Given the strong positive assessment of TCAB, evidence of substantial engagement of staff in the work, and the high volume of innovations tested, implemented, and sustained, TCAB appears to be a productive model for organizing and implementing a program of frontline-led improvement.

  8. Student-Led Campus Climate Change Initiatives in Canada

    ERIC Educational Resources Information Center

    Helferty, Anjali; Clarke, Amelia

    2009-01-01

    Purpose: The purpose of this paper is to provide a comprehensive list of student-led, campus-based climate change initiatives, and offers details on many specific cases. The paper also documents the roles students have played and considers the larger youth engagement implications. Many of these initiatives can be replicated elsewhere, thereby…

  9. Dynamics of Human Telomerase Holoenzyme Assembly and Subunit Exchange across the Cell Cycle*

    PubMed Central

    Vogan, Jacob M.; Collins, Kathleen

    2015-01-01

    Human telomerase acts on telomeres during the genome synthesis phase of the cell cycle, accompanied by its concentration in Cajal bodies and transient colocalization with telomeres. Whether the regulation of human telomerase holoenzyme assembly contributes to the cell cycle restriction of telomerase function is unknown. We investigated the steady-state levels, assembly, and exchange dynamics of human telomerase subunits with quantitative in vivo cross-linking and other methods. We determined the physical association of telomerase subunits in cells blocked or progressing through the cell cycle as synchronized by multiple protocols. The total level of human telomerase RNA (hTR) was invariant across the cell cycle. In vivo snapshots of telomerase holoenzyme composition established that hTR remains bound to human telomerase reverse transcriptase (hTERT) throughout all phases of the cell cycle, and subunit competition assays suggested that hTERT-hTR interaction is not readily exchangeable. In contrast, the telomerase holoenzyme Cajal body-associated protein, TCAB1, was released from hTR in mitotic cells coincident with TCAB1 delocalization from Cajal bodies. This telomerase holoenzyme disassembly was reversible with cell cycle progression without any change in total TCAB1 protein level. Consistent with differential cell cycle regulation of hTERT-hTR and TCAB1-hTR protein-RNA interactions, overexpression of hTERT or TCAB1 had limited if any influence on hTR assembly of the other subunit. Overall, these findings revealed a cell cycle regulation that disables human telomerase association with telomeres while preserving the co-folded hTERT-hTR ribonucleoprotein catalytic core. Studies here, integrated with previous work, led to a unifying model for telomerase subunit assembly and trafficking in human cells. PMID:26170453

  10. A complete vibrational study on a potential environmental toxicant agent, the 3,3',4,4'-tetrachloroazobenzene combining the FTIR, FTRaman, UV-Visible and NMR spectroscopies with DFT calculations.

    PubMed

    Castillo, María V; Pergomet, Jorgelina L; Carnavale, Gustavo A; Davies, Lilian; Zinczuk, Juan; Brandán, Silvia A

    2015-01-05

    In this study 3,3',4,4'-tetrachloroazobenzene (TCAB) was prepared and then characterized by infrared, Raman, multidimensional nuclear magnetic resonance (NMR) and ultraviolet-visible spectroscopies. The density functional theory (DFT) together with the 6-31G(*) and 6-311++G(**) basis sets were used to study the structures and vibrational properties of the two cis and trans isomers of TCAB. The harmonic vibrational wavenumbers for the optimized geometries were calculated at the same theory levels. A complete assignment of all the observed bands in the vibrational spectra of TCAB was performed combining the DFT calculations with the scaled quantum mechanical force field (SQMFF) methodology. The molecular electrostatic potentials, atomic charges, bond orders and frontier orbitals for the two isomers of TCAB were compared and analyzed. The comparison of the theoretical ultraviolet-visible spectrum with the corresponding experimental demonstrates a good concordance while the calculated (1)H and (13)C chemicals shifts are in good conformity with the corresponding experimental NMR spectra of TCAB in solution. The npp(*) transitions for both forms were studied by natural bond orbital (NBO) while the topological properties were calculated by employing Bader's Atoms in the Molecules (AIM) theory. This study shows that the cis and trans isomers exhibit different structural and vibrational properties and absorption bands. Copyright © 2014. Published by Elsevier B.V.

  11. Preventing Delays in First-Case Starts on the Neurosurgery Service: A Resident-Led Initiative at an Academic Institution.

    PubMed

    Han, Seunggu J; Rolston, John D; Zygourakis, Corinna C; Sun, Matthew Z; McDermott, Michael W; Lau, Catherine Y; Aghi, Manish K

    2016-01-01

    On-time starts for the first case of the day are critical to maintaining efficiency in operating rooms (ORs). We studied whether a resident-led initiative to ensure on-time site marking and documentation of surgical consent could lead to improved first-case start time. In a resident-led initiative at a large 600-bed academic hospital with 25 ORs, we aimed to complete site marking and surgical consents half an hour before the scheduled start time for all first-case neurosurgical patients. We monitored the occurrence of delayed first starts and the length of delay during our initiative, and compared these cases to neurosurgical cases 3 months before the implementation of the initiative and to first-start nonneurosurgical cases. In the year of the initiative, both site marking and surgical consents were completed 30 minutes before the case start in 97% of neurosurgical cases. The average delay across all first-case starts was reduced to 7.17 minutes (N = 1271), compared with 9.67 minutes before the intervention (N = 345). During the study period, non-neurosurgical cases were delayed on average 10.3 minutes (N = 3592). There was a significant difference in latencies between the study period and the period before the initiative (p < 0.001), and also between neurosurgical cases and nonneurosurgical cases (p < 0.001). There was no reduction in delay times seen on the non-neurosurgical services in the study period when compared to the case 3 months before. Considering its effect across 1271 cases, this initiative over 1 year resulted in a total reduction of 52 hours and 57 minutes in delays. Through a resident-led quality improvement program, neurosurgical trainees successfully reduced delays in first-case starts on a surgical service. Engaging physician trainees in quality improvement and enhancing OR efficiency can be successfully achieved and can have a significant clinical and financial effect. Copyright © 2015 Association of Program Directors in Surgery. Published by

  12. Effective Strategies to Spread Redesigning Care Processes Among Healthcare Teams.

    PubMed

    Lavoie-Tremblay, Mélanie; O'Connor, Patricia; Lavigne, Geneviève L; Briand, Anaïck; Biron, Alain; Baillargeon, Sophie; MacGibbon, Brenda; Ringer, Justin; Cyr, Guylaine

    2015-07-01

    The purpose of this study was to describe how spread strategies facilitate the successful implementation of the Transforming Care at the Bedside (TCAB) program and their impact on healthcare workers and patients in a major Canadian healthcare organization. This study used a qualitative and descriptive design with focus groups and individual interviews held in May 2014. Participants included managers and healthcare providers from eight TCAB units in a university health center in Quebec, Canada. The sample was composed of 43 individuals. The data were analyzed using NVivo according to the method proposed by Miles and Huberman. The first two themes that emerged from the analysis are related to context (organizational transition requiring many changes) and spread strategies for the TCAB program (senior management support, release time and facilitation, rotation of team members, learning from previous TCAB teams, and engaging patients). The last theme that emerged from the analysis is the impact on healthcare professionals (providing front-line staff and managers with the training they need to make changes, team leadership, and increasing receptivity to hearing patients' and families' needs and requests). This study describes the perspectives of managers and team members to provide a better understanding of how spread strategies can facilitate the successful implementation of the TCAB program in a Canadian healthcare organization. Spread strategies facilitate the implementation of changes to improve the quality and safety of care provided to patients. © 2015 Sigma Theta Tau International.

  13. Deconstructing the Carter Review: Competing Conceptions of Quality in England's "School-Led" System of Initial Teacher Education

    ERIC Educational Resources Information Center

    Mutton, Trevor; Burn, Katharine; Menter, Ian

    2017-01-01

    The commitment to establish a "school-led" system of teacher education in England, announced by the Coalition Government in 2011 and relentlessly pursued thereafter, represented a radical departure from previous kinds of initial teacher education partnership. While it is entirely consistent with a neoliberal agenda, with its strong…

  14. A Resident-led Initiative Improves Screening and Treatment for Vitamin D Deficiency in Patients with Hip Fractures.

    PubMed

    Lansdown, Drew A; Whitaker, Amanda; Wustrack, Rosanna; Sawyer, Aenor; Hansen, Erik N

    2017-01-01

    Acute hip fractures carry a high risk of morbidity and are associated with low vitamin D levels. Improvements in screening and treating low vitamin D levels may lead to lower fall rates and a lower likelihood of additional fragility fractures. However, patients with low vitamin D levels often remain unassessed and untreated, even after they experience these fractures. We wished to determine whether a resident-led initiative can improve (1) screening for and (2) treatment of vitamin D deficiency in patients with acute hip fractures. Our department initiated a housestaff-led, quality improvement project focused on screening and treating vitamin D deficiency in patients with acute hip fractures. Screening encompassed checking serum 25-hydroxyvitamin D level during the acute hospitalization, and treating was defined as starting supplementation before discharge when the serum 25-hydroxyvitamin D level was less than 30 ng/mL. To evaluate the efficacy of this program, an administrative database identified 283 patients treated surgically for an acute hip fracture between July 2010 and June 2014. This period included 2 years before program initiation (Year 1, n = 65 patients; Year 2, n = 61 patients), the initial program year (Year 3, n = 66 patients), and the subsequent program year (Year 4, n = 91 patients). Followup was extended to 6 weeks after treatment with 9.2% (26/282) of patients lost to followup. Eight patients were excluded owing to documented intolerance of vitamin D supplementation. There were no differences regarding patient demographics, fracture type, or treatment rendered across these 4 years. The primary endpoints were the proportion of patients screened and treated for vitamin D deficiency. The secondary endpoint was the continuation of vitamin D supplementation at the patient's 6 week followup, according to the patient's medication list at that visit. This analysis included all patients, assuming those lost to followup had not continued supplementation

  15. A nurse-led 'stop smoking' initiative.

    PubMed

    McGowan, E; MacAuley, D; Anderson, U

    A one-week smoking awareness initiative and subsequent audit in a general practice are described. All patients attending morning surgery during the study period were offered the opportunity to discuss smoking habits at a smoking awareness clinic: 84 smokers attended. They were interviewed by the practice preventive care nurse who took a smoking history, monitored carbon monoxide (CO Hb) levels and offered a follow-up appointment. CO Hb provided immediate feedback on the effect of smoking and patients who smoked 20 or more cigarettes per day had an average CO Hb of 16.1 per cent. Fifteen per cent of smokers made a commitment to stop smoking and agreed to attend follow-up clinics. A random sample (50) of attenders at the initial Smoking Awareness Clinic (84) were followed up by questionnaire six months later. There were 29 replies (58 per cent); 19 patients (65 per cent) found the visit to the clinic helpful, 14 (48 per cent) reduced the number of cigarettes they smoked, and 11 (38 per cent) altered some other aspect of their lifestyle, of whom four modified their diet and four increased exercise. Five patients claimed they had given up smoking.

  16. A physician-led initiative to improve clinical documentation results in improved health care documentation, case mix index, and increased contribution margin.

    PubMed

    Aiello, Francesco A; Judelson, Dejah R; Durgin, Jonathan M; Doucet, Danielle R; Simons, Jessica P; Durocher, Dawn M; Flahive, Julie M; Schanzer, Andres

    2018-05-04

    Clinical documentation is the key determinant of inpatient acuity of illness and payer reimbursement. Every inpatient hospitalization is placed into a diagnosis related group with a relative value based on documented procedures, conditions, comorbidities and complications. The Case Mix Index (CMI) is an average of these diagnosis related groups and directly impacts physician profiling, medical center profiling, reimbursement, and quality reporting. We hypothesize that a focused, physician-led initiative to improve clinical documentation of vascular surgery inpatients results in increased CMI and contribution margin. A physician-led coding initiative to educate physicians on the documentation of comorbidities and conditions was initiated with concurrent chart review sessions with coding specialists for 3 months, and then as needed, after the creation of a vascular surgery documentation guide. Clinical documentation and billing for all carotid endarterectomy (CEA) and open infrainguinal procedures (OIPs) performed between January 2013 and July 2016 were stratified into precoding and postcoding initiative groups. Age, duration of stay, direct costs, actual reimbursements, contribution margin (CM), CMI, rate of complication or comorbidity, major complication or comorbidity, severity of illness, and risk of mortality assigned to each discharge were abstracted. Data were compared over time by standardizing Centers for Medicare and Medicaid Services (CMS) values for each diagnosis related group and using a CMS base rate reimbursement. Among 458 CEA admissions, postcoding initiative CEA patients (n = 253) had a significantly higher CMI (1.36 vs 1.25; P = .03), CM ($7859 vs $6650; P = .048), and CMS base rate reimbursement ($8955 vs $8258; P = .03) than precoding initiative CEA patients (n = 205). The proportion of admissions with a documented major complication or comorbidity and complication or comorbidity was significantly higher after the coding initiative (43% vs

  17. A peer-led teaching initiative for foundation doctors.

    PubMed

    Ramsden, Sophie; Abidogun, Abiola; Stringer, Emma; Mahgoub, Sara; Kastrissianakis, Artemis; Baker, Paul

    2015-08-01

    Peer teaching has been used informally throughout the history of medical education. Formal studies within the medical student and allied health care professional communities have found it to be a popular, and highly effective, method of teaching. Newly qualified doctors are currently an underused resource in terms of teaching one another. A committee, made up of newly qualified doctors and postgraduate education staff, was established. Using only a few resources, this committee organised regular, peer-led tutorials and used educational needs assessment tools, such as questionnaires, to make improvements to early postgraduate training. A realistic and well-received intervention to improve the teaching of newly qualified doctors, which is feasible in the modern, busy health care setting. Other institutions may find this method and its resources valuable. Newly qualified doctors are currently an underused resource in terms of teaching one another. © 2015 John Wiley & Sons Ltd.

  18. Student-Led Parent-Teacher Conferences.

    ERIC Educational Resources Information Center

    Borba, John A.; Olvera, Cherise M.

    2001-01-01

    Outlines the six-stage process used at Gustine Middle School for student-led parent-teacher conferences. Discusses how this encourages students to participate actively in evaluating their own progress, which motivates them toward personal initiatives to inspire learning, and improves student communication about learning with both parents and…

  19. Laser and LED external teeth-bleaching

    NASA Astrophysics Data System (ADS)

    Zanin, Fatima A.; Brugnera, Aldo, Jr.; Marchesan, Melissa A.; Pecora, Jesus D.

    2004-09-01

    Teeth-bleaching is an initial phase in the reproduction of an aesthetic smile; thus, it is very important that the dentist knows how to diagnose the causes of color changes and indicate whitening before proposing dental treatment. Technological advances in teeth-whitening lead to the development of new techniques, improving comfort, security and decreasing time of execution: argon laser, diode Laser, LED whitening, xenon light whitening. The clearing agent used in all techniques, including home whitening, is hydrogen peroxide (H2O2) in different concentrations. In this study, the authors describe mechanisms of gel activation, the use of Laser and LED"s for teeth-bleaching, the importance of diagnosis and the comfort of the patient in in-office teeth-bleaching techniques.

  20. Protection against methanol-induced retinal toxicity by LED photostimulation

    NASA Astrophysics Data System (ADS)

    Whelan, Harry T.; Wong-Riley, Margaret T. T.; Eells, Janis T.

    2002-06-01

    We have initiated experiments designed to test the hypothesis that 670-nm Light-Emitting Diode (LED) exposure will attenuate formate-induced retinal dysfunction in a rodent model of methanol toxicity. Methanol intoxication produces toxic injury to the retina. The toxic metabolite formed in methanol intoxication is formic acid, a mitochondrial toxin known to inhibit cytochrome oxidase activity. 670-nm LED light has been hypothesized to act by stimulating cytochrome oxidase activity. To test this hypothesis, one group of animals was intoxicated with methanol, a second group was intoxicated with methanol and LED-treated and a third group was untreated. LED treatment (670 nm for 1 min 45 seconds equals 50 mW/cm2, 4 joules/cm2) was administered at 5, 25, and 50 hours after the initial dose of methanol. At 72 hours of methanol intoxication, retinal function was assessed by measurement of ERG responses and retinas were prepared for histologic analysis. ERG responses recorded in methanol-intoxicated animals revealed profound attenuation of both rod-dominated and UV-cone mediated responses. In contrast, methanol- intoxicated animals exposed to LED treatment exhibited a nearly complete recovery of rod-dominated ERG responses and a slight improvement of UV-cone mediated ERG responses. LED treatment also protected the retina against the histopathologic changes produced by formate in methanol intoxication. These data provide evidence that LED phototherapy protects the retina against the cytotoxic actions of formate and are consistent with the hypothesis that LED photostimulation improves mitochondrial respiratory chain function.

  1. LED based opto-wetting platforms for micromixing

    NASA Astrophysics Data System (ADS)

    Thomas, Tony; Narayanan Unni, Harikrishnan

    2018-02-01

    The digital microfluidics utilizes the gradient in wettability for droplet transportation. This paper reports a novel technique of LED induced wetting ( Opto-wetting) where a single low power LED (Light emitting diode) emitting light of wavelength 395nm peak with luminous intensity of 300mcd (milli candela) is used to move two droplets of 20μL each on a photo responsive substrate of azobenzene (C12H10N2) coated PDMS (Poly Dimethyl Siloxane) substrate. The PDMS substrate of size 5cmx2cmx0.5cm were modified by thin film coating of Azobenzene dissolved in olive oil solution. The LED was aligned vertically on the top of the substrate. The pulsed operation of LED induces a spatial gradient of surface energy due to the reversible process of photo isomerization of Azobenzene molecules coated on the surface. The Photo-isomerization changes the conformation of the molecules thereby changing its surface energy .The change in surface energy of the substrate induces a change in contact angle of the droplet which initiates its movement. Two water droplets each of 20μL were dispensed on the substrate using micro syringe. Two droplets which were initially at a few cm distance apart were gradually moved towards the focus of light and merged together. The urine droplets (20μL) were moved and mixed with the red dye reagent (20μL) by controlling the light intensity of the LED. This concept provides a cost effective technique of droplet manipulation in the Lab on a chip domain where various multiplexed operations on proteins and DNA droplets can be done for point of care diagnostics.

  2. Peer-led prenatal breast-feeding education: a viable alternative to nurse-led education.

    PubMed

    Rempel, Lynn A; Moore, Katrina C J

    2012-02-01

    To evaluate a prenatal breast-feeding class developed and facilitated by peer Breast-feeding Buddies. Non-equivalent control group quasi-experimental study comparing participants of the peer-led class (PLC) to those attending an established hospital-based breast-feeding nurse-led class (NLC). A brief questionnaire was completed immediately prior to the class, and telephone interviews were conducted approximately one week following the class, and one and six months post partum. 54 expectant mothers who registered for the community PLC and 55 expectant mothers who registered for the NLC. Breast-feeding intentions were measured at all time-points. Class evaluations, breast-feeding experiences, and breast-feeding support were measured at all post-class interviews. Both classes were considered worthwhile, but the PLC class was rated as more helpful and participants appreciated learning from the peers' personal experiences. Mothers taught by peers were more likely to access peer breast-feeding support. PLC participants initially decreased their prenatal breast-feeding duration intentions but had significantly stronger intentions to continue breast feeding at six months than did NLC mothers. A peer-led prenatal breast-feeding class is as effective as a traditional model of breast-feeding education and is a valuable tool to promote and support successful breast feeding. RECOMMENDATIONS FOR PRACTICE: Peer-led breast-feeding classes should be provided to enhance the accessibility of breast-feeding education and support for expectant mothers. Copyright © 2010 Elsevier Ltd. All rights reserved.

  3. ARC-2008-ACD08-0157-005

    NASA Image and Video Library

    2008-07-28

    NASA AA - Associate Administrator for Aeronautics Jai Shin visits Ames Research Center and tours the Vertical Motion Simulator (VMS, T-cab) Jaiwon Shin, Moffett Field Hangar 1 shows in the VMS visual scene.

  4. Spectral design flexibility of LED brings better life

    NASA Astrophysics Data System (ADS)

    Ou, Haiyan; Corell, Dennis; Ou, Yiyu; Poulsen, Peter B.; Dam-Hansen, Carsten; Petersen, Paul-Michael

    2012-03-01

    Light-emitting diodes (LEDs) are penetrating into the huge market of general lighting because they are energy saving and environmentally friendly. The big advantage of LED light sources, compared to traditional incandescent lamps and fluorescent light tubes, is the flexible spectral design to make white light using different color mixing schemes. The spectral design flexibility of white LED light sources will promote them for novel applications to improve the life quality of human beings. As an initial exploration to make use of the spectral design flexibility, we present an example: 'no blue' white LED light source for sufferers of disease Porphyria. An LED light source prototype, made of high brightness commercial LEDs applying an optical filter, was tested by a patient suffering from Porphyria. Preliminary results have shown that the sufferer could withstand the light source for much longer time than the standard light source. At last future perspectives on spectral design flexibility of LED light sources improving human being's life will be discussed, with focus on the light and health. The good health is ensured by the spectrum optimized so that vital hormones (melatonin and serotonin) are produced during times when they support human daily rhythm.

  5. Business-led efforts to control costs.

    PubMed

    Kenkel, P J

    1991-07-29

    Business-led initiatives to compare medical quality and prices are becoming commonplace as employers seek ways to cap medical expenses. But employers are meeting with varying degrees of cooperation from hospitals. The tale of two cities' efforts to pry open the secrets of controlling costs provides a vivid contrast in the way purchasers have tried to solve the cost-containment puzzle.

  6. Laser and LED external teeth-bleaching

    NASA Astrophysics Data System (ADS)

    Zanin, Fatima; Brugnera, Aldo, Jr.; Marchesan, Melissa A.; Pecora, Jesus D.

    2004-05-01

    Teeth-bleaching is an initial phase in the reproduction of an aesthetic smile; thus, it is very important that the dentist knows how to diagnose the causes of color changes and indicate whitening before proposing dental treatment. Technological advances in teeth-whitening lead to the development of new techniques, improving comfort, security and decreasing time of execution: argon laser, diode laser, LED whitening, xenon light whitening. The clearing agent used in all techniques, including home whitening, is hydrogen peroxide (H2O2) in different concentrations. In this study, the authors describe mechanisms of gel activation, the use of Laser and LED's for teeth-bleaching, the importance of diagnosis and the comfort of the patient in in-office teeth-bleaching techniques.

  7. Nurse-led versus doctor-led care for bronchiectasis.

    PubMed

    Lawton, Kathryn; Royals, Karen; Carson-Chahhoud, Kristin V; Campbell, Fiona; Smith, Brian J

    2018-06-20

    Specialist nursing roles to manage stable disease populations are being used to meet the needs of both patients and health services. With increasing cost pressures on health departments, alternative models such as nurse-led care are gaining momentum as a substitute for traditional doctor-led care. This review evaluates the safety, effectiveness, and health outcomes of nurses practising in autonomous roles while using advanced practice skills, within the context of bronchiectasis management in subacute, ambulatory, and/or community care. To compare the effectiveness of nurse-led care versus doctor-led care in the management of stable bronchiectasis. We searched the Cochrane Airways Group Specialised Register and bibliographies of selected papers in addition to grey literature such as electronic clinical trials registries. Searches were current as of March 2018. Randomised controlled trials were eligible for inclusion in the review. Two reviewers extracted and entered data from included studies. Primary outcomes were numbers of exacerbations requiring treatment with antibiotics, hospital admissions, and emergency department attendances. We included one United Kingdom (UK) study in the review. In this randomised controlled trial, a total of 80 participants, with a mean age of 58 years, were treated for 12 months by a specialist nurse or doctor, then were crossed over to the other clinician for the next 12 months. Two participants died during the study period. Six participants failed to cross over to nurse-led care because of unstable bronchiectasis. Overall, the level of study completion was high.Data show no difference in the numbers of exacerbations requiring treatment with antibiotics (rate ratio 1.09, 95% confidence interval (CI) 0.91 to 1.30, 80 participants, moderate-certainty evidence). Investigators reported more hospital admissions in the nurse-led care group (rate ratio 1.52, 95% CI 1.04 to 2.23, 80 participants, moderate-certainty evidence) and did not

  8. Progress in LED technology for solid-state lighting

    NASA Astrophysics Data System (ADS)

    Bhardwaj, Jy; Guth, Greg; Cesaratto, John M.; Shchekin, Oleg B.; Soer, Wouter A.; Götz, Werner; Bonné, Ron; Song, Zhihua F.; den Breejen, Jeroen

    2017-02-01

    As solid-state lighting adoption moves from bulb socket replacement to lighting system engineering, luminaire manufacturers are beginning to actualize far greater cost savings through luminaire optimization rather than the simplistic process of component cost pareto management. Indeed, there are an increasing number of applications in which we see major shifts in the value chain in terms of increasing the L1 (LED) and L2 (LED array on PCB) value. The L1 value increase stems from a number of factors ranging from simply higher performing LEDs reducing the LED count, to L1 innovation such as high voltage LEDs, optimizing driver efficiency or to the use of high luminance LEDs enabling compact optics, allowing not only more design freedom but also cost reduction through space and weight savings. The L2 value increase is realized predominantly through increasing L2 performance with the use of algorithms that optimize L1 selection and placement and/or through L2 integration of drivers, control electronics, sensors, secondary lens and/or environmental protection, which is also initiating level collapse in the value chain. In this paper we will present the L1 and L2 innovations that are enabling this disruption as well as provide examples of fixture/luminaire level benefits.

  9. Developing Sustainable Farmer-Led Extension Groups: Lessons from a Bangladeshi Case Study

    ERIC Educational Resources Information Center

    Islam, Md. Mofakkarul; Gray, David; Reid, Janet; Kemp, Peter

    2011-01-01

    The limited effectiveness and fiscal unsustainability of professional-led public sector extension systems in developing countries have aroused considerable interest in Farmer-led Extension (FLE) approaches in the recent decades. A key challenge facing these initiatives is a lack of sustainability of the farmer groups developed through project or…

  10. Yuma Border Patrol Lighting Retrofit: Final LED System Performance Assessment of Trial and Full Installation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wilkerson, Andrea; Sullivan, Gregory P.; Davis, Robert G.

    Along the Yuma Sector Border Patrol Area in Yuma, Arizona, the GATEWAY program conducted a trial evaluation in which the incumbent quartz metal halide area lighting was replaced with LED at three pole locations, and illuminance measurements were recorded initially and at 2500 hours, 5000 hours, 7000, and 11,000 hours of operation. Additionally, four second-generation LED luminaires installed as part of the full installation were evaluated initially and again after 4,000 hours of operation. While the initial energy, lighting quality, and maintenance benefits relative to the incumbent high-pressure sodium system were very satisfactory, the study raises important questions regarding themore » long-term performance of LED lighting systems in high-temperature environments.« less

  11. Community nurse-led initiation of antiviral therapy for chronic hepatitis C in people who inject drugs does not increase uptake of or adherence to treatment.

    PubMed

    Lewis, Heather; Kunkel, Jan; Axten, David; Dalton, Jane; Gardner, Hayley; Tippett, Andrew; Wynne, Stephanie; Wilkinson, Mandie; Foster, Graham R

    2016-11-01

    Chronic hepatitis C is common in people who inject drugs (PWID) and this population serves as a reservoir for infection. Treatment levels are low among this group, ranging from 1 to 19%. We explored whether a nurse-initiated community treatment model increased uptake of and adherence to interferon-based therapies. This was a cluster randomized trial of nurse-initiated versus physician-initiated antiviral therapy with pegylated interferon and ribavirin for hepatitis C virus in community clinics (trial registration: ISRCTN07774040). The proportion of participants initiating treatment during follow-up was 10% with nurse-initiated (6/62) and 9% with physician-initiated (6/76) therapy. Adherence was similar in both groups, with only one patient in each arm not adhering to therapy. There were no serious adverse events, but interferon-related side effects were common. Drug and alcohol use did not change during therapy. Despite easy access to antiviral therapy, uptake of treatment was poor, with no significant difference between the groups. Nurse-led initiation of interferon-based antiviral therapy in PWID did not lead to increased uptake of, response to or adherence with treatment. Further service improvement is unlikely to increase the proportion of PWID undergoing antiviral therapy for hepatitis C virus and early adoption of interferon-free regimens may increase the proportion initiating and completing treatment.

  12. Developing a nurse-led clinic using transformational leadership.

    PubMed

    Gousy, Mamood; Green, Kim

    2015-03-25

    Nurses are at the forefront of implementing and managing change, given constantly changing healthcare services and the increase in demand for health care. Therefore, it is important to identify the best style of leadership to engage nurses in implementing service-led improvements. This article explores the effects of transformational leadership in bringing about service-led improvements in health care, using the example of setting up a nurse-led acupuncture clinic to optimise the care of patients with chronic pain. Transformational leadership was used throughout the project - from the initial local planning, training and development, through to liaising with the appropriate staff and deciding on an evaluation strategy. Transformational leadership proved to be an effective way to engage and empower nurses and other members of the chronic pain team to enable them to achieve the project aims.

  13. "Light-box" accelerated growth of poinsettias: LED-only illumination

    NASA Astrophysics Data System (ADS)

    Weerasuriya, Charitha; Detez, Stewart; Hock Ng, Soon; Hughes, Andrew; Callaway, Michael; Harrison, Iain; Katkus, Tomas; Juodkazis, Saulius

    2018-01-01

    For the current commercialized agricultural industry which requires a reduced product lead time to customer and supply all year round, an artificial light emitting diodes (LEDs)-based illumination has high potential due to high efficiency of electrical-to-light conversion. The main advantage of the deployed Red Green Blue Amber LED lighting system is colour mixing capability, which means ability to generate all the colours in the spectrum by using three or four primary colours LEDs. The accelerated plant growth was carried out in a "light-box" which was made to generate an artificial day/night cycle by moving the colour mixing ratio along the colour temperature curve of the chromaticity diagram. The control group of plants form the same initial batch was grown on the same shelf in a greenhouse at the same conditions with addition of artificial illumination by incandescent lamps for few hours. Costs and efficiency projections of LED lamps for horticultural applications is discussed together with required capital investment. The total cost of the "light-box" including LED lamps and electronics was 850 AUD.

  14. CALiPER Report 21.3: Cost-Effectiveness of Linear (T8) LED Lamps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Naomi J.; Perrin, Tess E.; Royer, Michael P.

    2014-05-27

    Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15more » minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.« less

  15. CALiPER Report 21.3. Cost Effectiveness of Linear (T8) LED Lamps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2014-05-01

    Meeting performance expectations is important for driving adoption of linear LED lamps, but cost-effectiveness may be an overriding factor in many cases. Linear LED lamps cost more initially than fluorescent lamps, but energy and maintenance savings may mean that the life-cycle cost is lower. This report details a series of life-cycle cost simulations that compared a two-lamp troffer using LED lamps (38 W total power draw) or fluorescent lamps (51 W total power draw) over a 10-year study period. Variables included LED system cost ($40, $80, or $120), annual operating hours (2,000 hours or 4,000 hours), LED installation time (15more » minutes or 30 minutes), and melded electricity rate ($0.06/kWh, $0.12/kWh, $0.18/kWh, or $0.24/kWh). A full factorial of simulations allows users to interpolate between these values to aid in making rough estimates of economic feasibility for their own projects. In general, while their initial cost premium remains high, linear LED lamps are more likely to be cost-effective when electric utility rates are higher than average and hours of operation are long, and if their installation time is shorter.« less

  16. [Nurse-led in Primary Health Care setting: a well-timed and promising organizational innovation].

    PubMed

    Torres-Ricarte, Marc; Crusat-Abelló, Ernest; Peñuelas-Rodríguez, Silvia; Zabaleta-del-Olmo, Edurne

    2015-01-01

    At present, the severe economic crisis along with the increasing prevalence of chronic diseases is leading to different countries to consider updating their Primary Health Care (PHC) services in order to make them more efficient and reduce health inequalities. To that end, various initiatives are being carried out, such as the provision of Nurse-led services and interventions. The purpose of this article is to present the available knowledge, controversies and opportunities for Nurse-led initiatives in the setting of PHC. Nurse- led interventions or health services in PHC have proven to be equal or more effective than usual care in disease prevention, the routine follow-up of patients with chronic conditions, and first contact care for people with minor illness. However, as there are only a few health economic evaluation studies published their efficiency is still potential. In conclusion, the Nurse-led care could be an innovative organizational initiative with the potential to provide an adequate response to the contemporary health needs of the population, as well as an opportunity for the nursing profession and for PHC and health systems in general. Copyright © 2015 Elsevier España, S.L.U. All rights reserved.

  17. Comparison of instructor-led versus peer-led debriefing in nursing students.

    PubMed

    Roh, Young Sook; Kelly, Michelle; Ha, Eun Ho

    2016-06-01

    Despite its widespread support, the most effective simulation-based debriefing method has little evidence to support its efficacy. In this study, we compared the effect of peer-led and instructor-led debriefing among nursing students. The study was conducted with a non-equivalent control group using a pretest-post-test design. A convenience sample of third-year nursing students was used for the study, where 65 students enrolled in a 2-week clinical placement rotation were randomly assigned to the instructor-led group or peer-led group. The quality of cardiopulmonary resuscitation skills, satisfaction with simulation, and quality of debriefing in the peer-led group were compared to those in the instructor-led group. Group differences at each testing interval were analyzed using independent t-test. Nursing students in the instructor-led debriefing group showed better subsequent cardiopulmonary resuscitation performance, more satisfaction with simulation experience, and higher debriefing scores compared to the peer-led group. From our study, instructor-led debriefing is an effective method in improving skills performance, inducing favorable satisfaction, and providing better quality of debriefing among nursing students. © 2016 John Wiley & Sons Australia, Ltd.

  18. Commerical Transition to LEDs: A Pathway to High-Value Products

    NASA Technical Reports Server (NTRS)

    Stutte, Gary W.

    2015-01-01

    The use of light-emitting diodes (LEDs) to support plant growth is a radical departure from use of gas-discharge lamps, which were developed in mid-19th and widely adopted by the industry during the 20th century. Initial investigation by the National Aeronautics and Space Administration (NASA) in the late 1980s on the use of LEDs to grow plant in space is resulting in an industry-wide transition from gas discharge to solid-state lighting systems. This global transformation is given urgency by national policies to reduce energy consumption and being facilitated by ready access to information on LEDs. The combination of research, government policy, and information technology has resulted in an exponential increase in research into the use and application of LED technology in horticulture. Commercial horticulture has identified the opportunities provided by LEDs to optimize light spectra to promote growth, regulate morphology, increase nutrient content, and reduce operating costs. LED-light technology is enabling the development of innovative lighting systems, and is being incorporated into large-scale plant factories for the production of edible, ornamental, and medicinal plants. An overview of prevalence of readily accessible information on LEDs and implications for future adoption in horticulture is discussed.

  19. Design of an Oximeter Based on LED-LED Configuration and FPGA Technology

    PubMed Central

    Stojanovic, Radovan; Karadaglic, Dejan

    2013-01-01

    A fully digital photoplethysmographic (PPG) sensor and actuator has been developed. The sensing circuit uses one Light Emitting Diode (LED) for emitting light into human tissue and one LED for detecting the reflectance light from human tissue. A Field Programmable Gate Array (FPGA) is used to control the LEDs and determine the PPG and Blood Oxygen Saturation (SpO2). The configurations with two LEDs and four LEDs are developed for measuring PPG signal and Blood Oxygen Saturation (SpO2). N-LEDs configuration is proposed for multichannel SpO2 measurements. The approach resulted in better spectral sensitivity, increased and adjustable resolution, reduced noise, small size, low cost and low power consumption. PMID:23291575

  20. LEDs for Efficient Energy

    ERIC Educational Resources Information Center

    Guerin, David A.

    1978-01-01

    Light-emitting diodes (LEDs) are described and three classroom experiments are given, one to prove the, low power requirements and efficiency of LEDs, an LED on-off detector circuit, and the third an LED photoelectric smoke detector. (BB)

  1. Comparison between an instructor-led course and training using a voice advisory manikin in initial cardiopulmonary resuscitation skill acquisition.

    PubMed

    Min, Mun Ki; Yeom, Seok Ran; Ryu, Ji Ho; Kim, Yong In; Park, Maeng Real; Han, Sang Kyoon; Lee, Seong Hwa; Park, Sung Wook; Park, Soon Chang

    2016-09-01

    We compared training using a voice advisory manikin (VAM) with an instructor-led (IL) course in terms of acquisition of initial cardiopulmonary resuscitation (CPR) skills, as defined by the 2010 resuscitation guidelines. This study was a randomized, controlled, blinded, parallel-group trial. We recruited 82 first-year emergency medical technician students and distributed them randomly into two groups: the IL group (n=41) and the VAM group (n=37). In the IL-group, participants were trained in "single-rescuer, adult CPR" according to the American Heart Association's Basic Life Support course for healthcare providers. In the VAM group, all subjects received a 20-minute lesson about CPR. After the lesson, each student trained individually with the VAM for 1 hour, receiving real-time feedback. After the training, all subjects were evaluated as they performed basic CPR (30 compressions, 2 ventilations) for 4 minutes. The proportion of participants with a mean compression depth ≥50 mm was 34.1% in the IL group and 27.0% in the VAM group, and the proportion with a mean compression depth ≥40 mm had increased significantly in both groups compared with ≥50 mm (IL group, 82.9%; VAM group, 86.5%). However, no significant differences were detected between the groups in this regard. The proportion of ventilations of the appropriate volume was relatively low in both groups (IL group, 26.4%; VAM group, 12.5%; P=0.396). Both methods, the IL training using a practice-while-watching video and the VAM training, facilitated initial CPR skill acquisition, especially in terms of correct chest compression.

  2. Understanding and controlling chromaticity shift in LED devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Lynn; Mills, Karmann; Lamvik, Michael

    Chromaticity shift in light-emitting diode (LED) devices arises from multiple mechanisms, and at least five different chromaticity shift modes (CSMs) have been identified to date. This paper focuses on the impacts of irreversible phosphor degradation as a cause of chromaticity shifts in LED devices. The nitride phosphors used to produce warm white LEDs are especially vulnerable to degradation due to thermal and chemical effects such as reactions with oxygen and water. As a result, LED devices utilizing these phosphors were found to undergo either a green shift or, less commonly, a red shift depending on the phosphor mix in themore » LED devices. These types of chromaticity shifts are classified as CSM-2 (green shift) and CSM-5 (red shift). This paper provides an overview of the kinetic processes responsible for green and red chromaticity shifts along with examples from accelerated stress testing of 6” downlights. Both CSMs appear to proceed through analogous mechanisms that are initiated at the surface of the phosphor. A green shift is produced by the surface oxidation of the nitride phosphor that changes the emission profile to lower wavelengths. As the surface oxidation reaction proceeds, reactant limitations slow the rate and bulk oxidation processes become more prevalent. We found that a red chromaticity shift arises from quenching of the green phosphor, also possibly due to surface reactions of oxygen, which shift the emission chromaticity in the red direction. In conclusion, we discuss the implications of these findings on projecting chromaticity.« less

  3. Broadband Radiometric LED Measurements

    PubMed Central

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2017-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed. PMID:28649167

  4. Broadband radiometric LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Cooksey, C. C.; Yoon, H. W.; Hanssen, L. M.; Podobedov, V. B.; Vest, R. E.; Arp, U.; Miller, C. C.

    2016-09-01

    At present, broadband radiometric LED measurements with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  5. Broadband Radiometric LED Measurements.

    PubMed

    Eppeldauer, G P; Cooksey, C C; Yoon, H W; Hanssen, L M; Podobedov, V B; Vest, R E; Arp, U; Miller, C C

    2016-01-01

    At present, broadband radiometric measurements of LEDs with uniform and low-uncertainty results are not available. Currently, either complicated and expensive spectral radiometric measurements or broadband photometric LED measurements are used. The broadband photometric measurements are based on the CIE standardized V(λ) function, which cannot be used in the UV range and leads to large errors when blue or red LEDs are measured in its wings, where the realization is always poor. Reference irradiance meters with spectrally constant response and high-intensity LED irradiance sources were developed here to implement the previously suggested broadband radiometric LED measurement procedure [1, 2]. Using a detector with spectrally constant response, the broadband radiometric quantities of any LEDs or LED groups can be simply measured with low uncertainty without using any source standard. The spectral flatness of filtered-Si detectors and low-noise pyroelectric radiometers are compared. Examples are given for integrated irradiance measurement of UV and blue LED sources using the here introduced reference (standard) pyroelectric irradiance meters. For validation, the broadband measured integrated irradiance of several LED-365 sources were compared with the spectrally determined integrated irradiance derived from an FEL spectral irradiance lamp-standard. Integrated responsivity transfer from the reference irradiance meter to transfer standard and field UV irradiance meters is discussed.

  6. White LED performance

    NASA Astrophysics Data System (ADS)

    Gu, Yimin; Narendran, Nadarajah; Freyssinier, Jean Paul

    2004-10-01

    Two life tests were conducted to compare the effects of drive current and ambient temperature on the degradation rate of 5 mm and high-flux white LEDs. Tests of 5 mm white LED arrays showed that junction temperature increases produced by drive current had a greater effect on the rate of light output degradation than junction temperature increases from ambient heat. A preliminary test of high-flux white LEDs showed the opposite effect, with junction temperature increases from ambient heat leading to a faster depreciation. However, a second life test is necessary to verify this finding. The dissimilarity in temperature effect among 5 mm and high-flux LEDs is likely caused by packaging differences between the two device types.

  7. Are nurse-led chemotherapy clinics really nurse-led? An ethnographic study.

    PubMed

    Farrell, Carole; Walshe, Catherine; Molassiotis, Alex

    2017-04-01

    The number of patients requiring ambulatory chemotherapy is increasing year on year, creating problems with capacity in outpatient clinics and chemotherapy units. Although nurse-led chemotherapy clinics have been set up to address this, there is a lack of evaluation of their effectiveness. Despite a rapid expansion in the development of nursing roles and responsibilities in oncology, there is little understanding of the operational aspects of nurses' roles in nurse-led clinics. To explore nurses' roles within nurse-led chemotherapy clinics. A focused ethnographic study of nurses' roles in nurse-led chemotherapy clinics, including semi-structured interviews with nurses. Four chemotherapy units/cancer centres in the UK PARTICIPANTS: Purposive sampling was used to select four cancer centres/units in different geographical areas within the UK operating nurse-led chemotherapy clinics. Participants were 13 nurses working within nurse-led chemotherapy clinics at the chosen locations. Non-participant observation of nurse-led chemotherapy clinics, semi-structured interviews with nurse participants, review of clinic protocols and associated documentation. 61 nurse-patient consultations were observed with 13 nurses; of these 13, interviews were conducted with 11 nurses. Despite similarities in clinical skills training and prescribing, there were great disparities between clinics run by chemotherapy nurses and those run by advanced nurse practitioners. This included the number of patients seen within each clinic, operational aspects, nurses' autonomy, scope of practice and clinical decision-making abilities. The differences highlighted four different levels of nurse-led chemotherapy clinics, based on nurses' autonomy and scope of clinical practice. However, this was heavily influenced by medical consultants. Several nurses perceived they were undertaking holistic assessments, however they were using medical models/consultation styles, indicating medicalization of nurses' roles

  8. Application Summary Report 22: LED MR16 Lamps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Royer, Michael P.

    2014-07-23

    This report analyzes the independently tested photometric performance of 27 LED MR16 lamps. It describes initial performance based on light output, efficacy, distribution, color quality, electrical characteristics, and form factor, with comparisons to a selection of benchmark halogen MR16s and ENERGY STAR qualification thresholds. Three types of products were targeted. First, CALiPER sought 3000 K lamps with the highest rated lumen output (i.e., at least 500 lm) or a claim of equivalency to a 50 W halogen MR16 or higher. The test results indicate that while the initial performance of LED MR16s has improved across the board, market-available products stillmore » do not produce the lumen output and center beam intensity of typical 50 W halogen MR16 lamps. In fact, most of the 18 lamps in this category had lower lumen output and center beam intensity than a typical 35 W halogen MR16 lamp. Second, CALiPER sought lamps with a CRI of 90 or greater. Only four manufacturers were identified with a product in this category. CALiPER testing confirmed the performance of these lamps, which are a good option for applications where high color fidelity is needed. A vast majority of the LED MR16 lamps have a CRI in the low 80s; this is generally acceptable for ambient lighting, but may not always be acceptable for focal lighting. For typical LED packages, there is a fundamental tradeoff between CRI and efficacy, but the lamps in the high-CRI group in this report still offer comparable performance to the rest of the Series 22 products in other performance areas. Finally, CALiPER sought lamps with a narrow distribution, denoted as a beam angle less than 15°. Five such lamps were purchased. Notably, no lamp was identified as having high lumen output (500 lumens or greater), high CRI (90 or greater), a narrow distribution (15° or less), and an efficacy greater than 60 lm/W. This would be an important achievement for LED MR16s especially if output could reach approximately 700 800

  9. Colonised by Quality? Teacher Identities in a Research-Led Institution

    ERIC Educational Resources Information Center

    Skelton, Alan

    2012-01-01

    This article explores the impact of quality assurance and enhancement initiatives on teacher identities in higher education. Data from an interview-based study of a research-led institution in the United Kingdom are drawn upon to consider the implications of quality--for example, whether it has captured the inner assumptive worlds of higher…

  10. Twelve tips on setting up and running a peer-led medical education society.

    PubMed

    Fleming-Nouri, Alex; Crocombe, Dominic; Sammaraiee, Yezen

    2016-12-01

    Peer-led teaching is an established paradigm with benefits for student teachers, learners and the wider medical community. Students are increasingly taking ownership of such teaching, which has fuelled the creation of new peer-led medical education societies at universities around the UK. Students wishing to undertake such an endeavor must contend with concerns over the quality of peer-led teaching, logistical challenges, lack of senior support and difficulties accessing relevant resources to design and appraise their initiatives. Peer-led medical education societies represent a relatively novel concept, and students may struggle to find practical information on how to approach these challenges. We propose that these obstacles can be overcome by thorough event planning, understanding the role and features of high quality peer-led education in supplementing medical school curricula, maintaining a strong working relationship with local medical faculty, and learning from the wider medical education community.

  11. Potential benefits of student- and junior doctor-led textbooks.

    PubMed

    Qureshi, Zeshan U; Lattey, Katherine; Bryne, Patrick; Rodrigues, Mark; Ross, Michael; Maxwell, Simon

    2015-06-01

    Medical textbooks are an important teaching supplement. Few have junior doctors or medical students ('juniors') as primary contributors. However, the strengths of junior-led face-to-face teaching are now well-established, and we hypothesized that similar advantages would be transferrable to a textbook setting. Juniors were approached to contribute to an independently published medical textbook, with senior clinicians recruited in parallel to ensure factual accuracy. Juniors directed every aspect of textbook writing and the production process. The published book stressed that it was an open collaboration with readers, inviting them to get in touch to evaluate the text and suggest ideas for new titles. Of 75 respondents, 93 % awarded the first textbook in the series 4 or 5 out of 5 for overall quality. Five other titles have been released, with seven more in development. Over 100 juniors are currently involved, with two students progressing from reviewers to editors after less than a year of mentorship. Juniors can be a motivated, dynamic, innovative group, capable of significant contributions to the medical textbook literature. This initiative has generated a sustainable infrastructure to facilitate junior-led publishing, and has the capacity for expansion to accommodate new initiatives and ideas.

  12. Design method of LED rear fog lamp based on freeform micro-surface reflectors

    NASA Astrophysics Data System (ADS)

    Yu, Jindong; Wu, Heng

    2017-11-01

    We propose a practical method for the design of a light-emitting diode (LED) rear fog lamp based on freeform micro-surface reflectors. The lamp consists of nine LEDs and each of them has a freeform micro-surface reflector correspondingly. The micro-surface reflector design includes three steps. An initial freeform reflector is first built based on the light energy maps. The micro-surface reflector is then constructed on the bias of the initial one. Finally, a two-step method is designed to optimize the micro-surface reflector. With the proposed method, a module is designed and LCW DURIS E5 LED source whose emitting surface is 5.7 mm × 3.0 mm is adopted for simulation. A prototype is also assembled and fabricated to verify the real performance. Both the simulation and experimental results demonstrate that the luminous intensity distribution can well fulfill the requirements of ECE No.38 regulation. Furthermore, more than 79% energy can be saved when compared with the rear fog lamps using conventional sources.

  13. Comparing Smoking Cessation Outcomes in Nurse-Led and Physician-Led Primary Care Visits.

    PubMed

    Byers, Marcia A; Wright, Patricia; Tilford, John Mick; Nemeth, Lynne S; Matthews, Ellyn; Mitchell, Anita

    Smoking is a significant public health concern in the United States, yet 50% of patients do not receive recommended tobacco use screening and counseling. This project compared smoking cessation rates in newly reimbursable nurse-led wellness visits with rates in physician-led visits. Although the findings were not statistically significant, they suggested that smoking cessation is at least equivalent in patients who attend nurse-led visits compared with physician-led visits and may be higher.

  14. Dynamic mechanical thermal analysis of composite resins with CQ and PPD as photo-initiators photoactivated by QTH and LED units.

    PubMed

    Brandt, William Cunha; Silva, Cristina Gomes; Frollini, Elisabete; Souza-Junior, Eduardo Jose Carvalho; Sinhoreti, Mário Alexandre Coelho

    2013-08-01

    The aim of this study was to evaluate the thermal and mechanical properties of the composite resins containing the photo-initiators camphorquinone (CQ) and/or phenyl-propanodione (PPD) when photoactivated with halogen lamp (XL2500/3M-ESPE), monowave (UltraBlueIS/DMC) and polywave (UltraLume5/Ultradent) LED units. A blend of BisGMA, UDMA, BisEMA and TEGDMA was prepared with the same wt% of photo-initiators CQ and/or PPD and 65wt% of silaneted filler particles. Compression strength (CS), diametral tensile strength (DTS) and diametral modulus (DM) were tested. Thermogravimetric analysis (TGA) was made and the lost residual monomer were verified. Dynamic mechanical thermal analysis (DMTA) was used for to analyze the glass transition temperature (Tg) and the storage modulus in 37°C. Degree of conversion (DC) was accomplished in the same samples of DMA using middle-infrared spectroscopy (mid-IR). CQ, CQ/PPD and PPD obtained the same results for all mechanical properties (CS, DTS and DM), lost residual monomer and storage modulus in 37°C, regardless LCU used. The results of Tg showed that the combination PPD-UltraLume5 produced the highest values. DC showed that the combination CQ-UltraLume5 resulted in the highest values and PPD-XL2500 in the lowest DC values. The study shows that PPD is not only effective photosensitizers, but also photocrosslinking agents for dental composite resins with a similar efficiency to CQ. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. LED lamp

    DOEpatents

    Galvez, Miguel; Grossman, Kenneth; Betts, David

    2013-11-12

    There is herein described a lamp for providing white light comprising a plurality of light sources positioned on a substrate. Each of said light sources comprises a blue light emitting diode (LED) and a dome that substantially covers said LED. A first portion of said blue light from said LEDs is transmitted through said domes and a second portion of said blue light is converted into a red light by a first phosphor contained in said domes. A cover is disposed over all of said light sources that transmits at least a portion of said red and blue light emitted by said light sources. The cover contains a second phosphor that emits a yellow light in response to said blue light. The red, blue and yellow light combining to form the white light and the white light having a color rendering index (CRI) of at least about 80.

  16. Teacher Identities in a Research-Led Institution: In the Ascendancy or on the Retreat?

    ERIC Educational Resources Information Center

    Skelton, Alan

    2012-01-01

    This article explores how teacher identities are negotiated within a research-led institution in the UK. Over the last decade a wide range of initiatives has been introduced to promote teaching in higher education. Research has shown, however, that these initiatives have met with limited success in terms of changing predominant values and culture.…

  17. A Scoping Review of Peer-led Education in Patient Safety Training

    PubMed Central

    McLachlan, Andrew J.; Chen, Timothy F.

    2018-01-01

    Objective. To examine the literature pertaining to the use of peer-led education in patient safety. Findings. Four studies met the inclusion criteria: two were conducted in health care students and two in medical practitioners. Three studies used pre-post evaluation, with one containing a comparator group. One study a post-intervention evaluation only. All studies undertook Kirkpatrick Level 2 evaluations, showing significant improvements in attitudes and knowledge. One study undertook Level 3 and 4 evaluations, showing improvement in self-reported behaviors and engagement in quality improvement initiatives. Summary. There are few studies evaluating peer-led education in patient safety and formal and high-quality evaluations are lacking. PMID:29606704

  18. Study on method to simulate light propagation on tissue with characteristics of radial-beam LED based on Monte-Carlo method.

    PubMed

    Song, Sangha; Elgezua, Inko; Kobayashi, Yo; Fujie, Masakatsu G

    2013-01-01

    In biomedical, Monte-carlo simulation is commonly used for simulation of light diffusion in tissue. But, most of previous studies did not consider a radial beam LED as light source. Therefore, we considered characteristics of a radial beam LED and applied them on MC simulation as light source. In this paper, we consider 3 characteristics of radial beam LED. The first is an initial launch area of photons. The second is an incident angle of a photon at an initial photon launching area. The third is the refraction effect according to contact area between LED and a turbid medium. For the verification of the MC simulation, we compared simulation and experimental results. The average of the correlation coefficient between simulation and experimental results is 0.9954. Through this study, we show an effective method to simulate light diffusion on tissue with characteristics for radial beam LED based on MC simulation.

  19. Spectral and Power Stability Tests of Deep UV LEDs for AC Charge Management

    NASA Astrophysics Data System (ADS)

    Sun, Ke-Xun; Higuchi, Sei; Goh, Allex; Allard, Brett; Gill, Dale; Buchman, Saps; Byer, Robert

    2006-11-01

    Deep ultraviolet (UV) LEDs have recently been used in AC charge management experiments to support gravitational reference sensors for future space missions. The UV LED based charge management system offers compact size, light weight, and low power consumption compared to plasma sources. The AC charge management technique, which is enabled by easy modulation of UV LED output, achieves higher dynamic range for charge control. Further, the high modulation frequency, which is out of the gravitational wave detection band, reduces disturbances to the proof mass. However, there is a need to test and possibly improve the lifetime of UV LEDs, which were developed only a year ago. We have initiated a series of spectral and power stability tests for UV LEDs and designed experiments according to the requirements of AC charge management. We operate UV LEDs with a modulated current drive and maintain the operating temperature at 22 °C,28 similar to the LISA spacecraft working condition. The testing procedures involve measuring the baseline spectral shape and output power level prior to the beginning of the tests and then re-measuring the same quantities periodically. As of the date of submission (August 28th, 2006), we have operated a UV LED for more than 2,700 hours.

  20. UV-LED-based charge control for LISA

    NASA Astrophysics Data System (ADS)

    Olatunde, Taiwo; Shelley, Ryan; Chilton, Andrew; Ciani, Giacomo; Mueller, Guido; Conklin, John

    2014-03-01

    The test masses inside the LISA gravitational reference sensors (GRS) must maintain almost pure geodesic motion for gravitational waves to be successfully detected. The residual accelerations have to stay below 3fm/s2/rtHz at all frequencies between 0.1 and 3 mHz. One of the well known noise sources is associated with the charges on the test masses which couple to stray electrical potentials and external electro-magnetic fields. The LISA pathfinder (LPF) will use Hg-discharge lamps emitting mostly around 253 nm to discharge the test masses via photoemission in its 2015/16 flight. A future LISA mission launched around 2030 will likely replace the lamps with newer UV-LEDs. UV-LEDs have a lower mass, a better power efficiency, and are smaller than their Hg counterparts. Furthermore, the latest generation produces light at 240 nm, with energy well above the work function of pure gold. I will describe a preliminary design for effective charge control through photoelectric effect by using these LEDs. The effectiveness of this method is verified by taking Quantum Efficiency (QE) measurements which relate the number of electrons emitted to the number of photons incident on the Au test mass surface. This presentation addresses our initial results and future plans which includes implementation and testing in the UF torsion pendulum and space-qualification in a small satellite mission which will launch in the summer of 2014, through a collaboration with Stanford, KACST, and NASA Ames Research Center.

  1. Dual LED/incandescent security fixture

    DOEpatents

    Gauna, Kevin Wayne

    2005-06-21

    A dual LED and incandescent security lighting system uses a hybrid approach to LED illumination. It combines an ambient LED illuminator with a standard incandescent lamp on a motion control sensor. The LED illuminator will activate with the onset of darkness (daylight control) and typically remain on during the course of the night ("always on"). The LED illumination, typically amber, is sufficient to provide low to moderate level lighting coverage to the wall and ground area adjacent to and under the fixture. The incandescent lamp is integrated with a motion control circuit and sensor. When movement in the field of view is detected (after darkness), the incandescent lamp is switched on, providing an increased level of illumination to the area. Instead of an "always on" LED illuminator, the LEDs may also be switched off when the incandescent lamp is switched on.

  2. CALiPER Report 23: Photometric Testing of White Tunable LED Luminaires

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None, None

    2016-01-01

    This report documents an initial investigation of photometric testing procedures for white-tunable LED luminaires and summarizes the key features of those products. Goals of the study include understanding the amount of testing required to characterize a white-tunable product, and documenting the performance of available color-tunable luminaires that are intended for architectural lighting.

  3. Department-Initiated Change

    ERIC Educational Resources Information Center

    Watson, Anne; De Geest, Els

    2014-01-01

    This paper reports the activity of three secondary school mathematics departments in England in self-initiated states of change that led to overall improvements in students' achievements when compared to previous cohorts. This took place without intervention and without their participation in external projects. They provide examples of departments…

  4. Numerical simulation and experimental investigation of GaN-based flip-chip LEDs and top-emitting LEDs.

    PubMed

    Liu, Xingtong; Zhou, Shengjun; Gao, Yilin; Hu, Hongpo; Liu, Yingce; Gui, Chengqun; Liu, Sheng

    2017-12-01

    We demonstrate a GaN-based flip-chip LED (FC-LED) with a highly reflective indium-tin oxide (ITO)/distributed Bragg reflector (DBR) ohmic contact. A transparent ITO current spreading layer combined with Ta 2 O 5 /SiO 2 double DBR stacks is used as a reflective p-type ohmic contact in the FC-LED. We develop a strip-shaped SiO 2 current blocking layer, which is well aligned with a p-electrode, to prevent the current from crowding around the p-electrode. Our combined numerical simulation and experimental results revealed that the FC-LED with ITO/DBR has advantages of better current spreading and superior heat dissipation performance compared to top-emitting LEDs (TE-LEDs). As a result, the light output power (LOP) of the FC-LED with ITO/DBR was 7.6% higher than that of the TE-LED at 150 mA, and the light output saturation current was shifted from 130.9  A/cm 2 for the TE-LED to 273.8  A/cm 2 for the FC-LED with ITO/DBR. Owing to the high reflectance of the ITO/DBR ohmic contact, the LOP of the FC-LED with ITO/DBR was 13.0% higher than that of a conventional FC-LED with Ni/Ag at 150 mA. However, because of the better heat dissipation of the Ni/Ag ohmic contact, the conventional FC-LED with Ni/Ag exhibited higher light output saturation current compared to the FC-LED with ITO/DBR.

  5. Multiple pedestrian detection using IR LED stereo camera

    NASA Astrophysics Data System (ADS)

    Ling, Bo; Zeifman, Michael I.; Gibson, David R. P.

    2007-09-01

    As part of the U.S. Department of Transportations Intelligent Vehicle Initiative (IVI) program, the Federal Highway Administration (FHWA) is conducting R&D in vehicle safety and driver information systems. There is an increasing number of applications where pedestrian monitoring is of high importance. Visionbased pedestrian detection in outdoor scenes is still an open challenge. People dress in very different colors that sometimes blend with the background, wear hats or carry bags, and stand, walk and change directions unpredictably. The background is various, containing buildings, moving or parked cars, bicycles, street signs, signals, etc. Furthermore, existing pedestrian detection systems perform only during daytime, making it impossible to detect pedestrians at night. Under FHWA funding, we are developing a multi-pedestrian detection system using IR LED stereo camera. This system, without using any templates, detects the pedestrians through statistical pattern recognition utilizing 3D features extracted from the disparity map. A new IR LED stereo camera is being developed, which can help detect pedestrians during daytime and night time. Using the image differencing and denoising, we have also developed new methods to estimate the disparity map of pedestrians in near real time. Our system will have a hardware interface with the traffic controller through wireless communication. Once pedestrians are detected, traffic signals at the street intersections will change phases to alert the drivers of approaching vehicles. The initial test results using images collected at a street intersection show that our system can detect pedestrians in near real time.

  6. Community-led initiative for control of anemia among children 6 to 35 months of age and unmarried adolescent girls in rural Wardha, India.

    PubMed

    Dongre, Amol R; Deshmukh, Pradeep R; Garg, Bishan S

    2011-12-01

    Studies in India have reported a high prevalence of nutritional anemia among children and adolescent girls. Nutritional anemia is associated with impaired mental, physical, and cognitive performance in children and is a significant risk factor for maternal mortality. To evaluate the effect of a community-led initiative for control of nutritional anemia among children 6 to 35 months of age and unmarried rural adolescent girls 12 to 19 years of age. This Participatory Action Research was done in 23 villages of the Primary Health Centre, Anji, in Wardha District of Maharashtra. In February and March 2008, needs assessment was undertaken by interviewing the mothers of 261 children and 260 adolescent girls. Hemoglobin levels of adolescent girls and children were measured with the use of the hemoglobin color scale. The girls were given weekly iron-folic acid tablets, and the children were given daily liquid iron prophylaxis for 100 days in a year through community participation. The adolescent girls and the mothers of the children and adolescent girls were also given nutritional education on the benefits and side effects of iron supplementation. In June and July 2008, follow-up assessment was performed by survey and force field analysis. There was a significant reduction in the prevalence of nutritional anemia from 73.8% to 54.6% among the adolescent girls and from 78.2% to 64.2% among the children. There was improvement in awareness of iron-rich food items among the adolescent girls and the mothers of the children. The benefits to girls, such as increase in appetite and reduction in scanty menses, tiredness, and weakness, acted as positive factors leading to better compliance with weekly iron supplementation. The benefits to children perceived by the mothers, such as increase in appetite, weight gain, reduction in irritability, and reduction in mud-eating behavior, acted as a dominant positive force and generated demand for iron syrup. The community-led initiative for

  7. Enabling Initiative and Enterprise: Faculty-Led Course Redesign in a STEM Discipline

    ERIC Educational Resources Information Center

    Dee, Jay R.; Henkin, Alan B.; Hearne, Jennifer L.

    2011-01-01

    This study focuses on processes and outcomes associated with a faculty grassroots initiative to reform teaching and learning in an introductory chemistry course at a research university. The purpose of this study is threefold. First, the study considers faculty groups and teams as sites and sources of pedagogical change in an effort to improve…

  8. The impact of a national clinician-led audit initiative on care and mortality after hip fracture in England: an external evaluation using time trends in non-audit data.

    PubMed

    Neuburger, Jenny; Currie, Colin; Wakeman, Robert; Tsang, Carmen; Plant, Fay; De Stavola, Bianca; Cromwell, David A; van der Meulen, Jan

    2015-08-01

    Hip fracture is the most common serious injury of older people. The UK National Hip Fracture Database (NHFD) was launched in 2007 as a national collaborative, clinician-led audit initiative to improve the quality of hip fracture care, but has not yet been externally evaluated. We used routinely collected data on 471,590 older people (aged 60 years and older) admitted with a hip fracture to National Health Service (NHS) hospitals in England between 2003 and 2011. The main variables of interest were the use of early surgery (on day of admission, or day after) and mortality at 30 days from admission. We compared time trends in the periods 2003-2007 and 2007-2011 (before and after the launch of the NHFD), using Poisson regression models to adjust for demographic changes. The number of hospitals participating in the NHFD increased from 11 in 2007 to 175 in 2011. From 2007 to 2011, the rate of early surgery increased from 54.5% to 71.3%, whereas the rate had remained stable over the period 2003-2007. Thirty-day mortality fell from 10.9% to 8.5%, compared with a small reduction from 11.5% to 10.9% previously. The annual relative reduction in adjusted 30-day mortality was 1.8% per year in the period 2003-2007, compared with 7.6% per year over 2007-2011 (P<0.001 for the difference). The launch of a national clinician-led audit initiative was associated with substantial improvements in care and survival of older people with hip fracture in England.

  9. LED lamp color control system and method

    DOEpatents

    Gaines, James; Clauberg, Bernd; Van Erp, Josephus A.M.

    2013-02-05

    An LED lamp color control system and method including an LED lamp having an LED controller 58; and a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 determines whether the LED source 80 is in a feedback controllable range, stores measured optical flux for the LED source 80 when the LED source 80 is in the feedback controllable range, and bypasses storing the measured optical flux when the LED source 80 is not in the feedback controllable range.

  10. Peer-led and professional-led group interventions for people with co-occurring disorders: a qualitative study.

    PubMed

    Pallaveshi, Luljeta; Balachandra, Krishna; Subramanian, Priya; Rudnick, Abraham

    2014-05-01

    This pilot study evaluated the experience of people with co-occurring disorders (mental illness and addiction) in relation to peer-led and professional-led group interventions. The study used a qualitative (phenomenological) approach to evaluate the experience of a convenience sample of 6 individuals with co-occurring disorders who participated in up to 8 sessions each of both peer-led and professional-led group interventions (with a similar rate of attendance in both groups). The semi-structured interview data were coded and thematically analyzed. We found 5 themes within and across the 2 interventions. In both groups, participants experienced a positive environment and personal growth, and learned, albeit different things. They were more comfortable in the peer-led group and acquired more knowledge and skills in the professional-led group. Offering both peer-led and professional-led group interventions to people with co-occurring disorders may be better than offering either alone.

  11. Demonstration Assessment of Light-Emitting Diode (LED) Roadway Lighting at the I-35W Bridge, Minneapolis, MN

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, Bruce R.; Myer, Michael

    2009-08-31

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology conducted in 2009 at the recently reconstructed I-35W bridge in Minneapolis, MN. The project was supported under the U.S. Department of Energy (DOE) Solid-State Lighting GATEWAY Technology Demonstration Program. Other participants in the demonstration project included the Minnesota Department of Transportation (Mn/DOT), Federal Highways Administration (FHWA), and BetaLED™ (a division of Ruud Lighting). Pacific Northwest National Laboratory (PNNL) conducted the measurements and analysis of the results. DOE has implemented a three-year evaluation of the LED luminaires in this installation in order to develop new longitudinalmore » field data on LED performance in a challenging, real-world environment. This document provides information through the initial phase of the I-35W bridge project, up to and including the opening of the bridge to the public and the initial feedback received on the LED lighting installation from bridge users. Initial findings of the evaluation are favorable, with minimum energy savings level of 13% for the LED installation relative to the simulated base case using 250W high-pressure sodium (HPS) fixtures. The LEDs had an average illuminance level of 0.91 foot candles compared to 1.29 fc for the HPS lamps. The LED luminaires cost $38,000 more than HPS lamps, yielding a lengthy payback period, however the bridge contractor had offered to include the LED luminaires as part of the construction package at no additional cost. One potentially significant benefit of the LEDs in this installation is avoiding rolling lane closures on the heavily-traveled interstate bridge for the purpose of relamping the HPS fixtures. Rolling lane closures involve multiple crew members and various maintenance and safety vehicles, diversion of traffic, as well as related administrative tasks (e.g., approvals, scheduling, etc.). Mn/DOT records show an average cost

  12. A brief history of LED photopolymerization.

    PubMed

    Jandt, Klaus D; Mills, Robin W

    2013-06-01

    The majority of modern resin-based oral restorative biomaterials are cured via photopolymerization processes. A variety of light sources are available for this light curing of dental materials, such as composites or fissure sealants. Quartz-tungsten-halogen (QTH) light curing units (LCUs) have dominated light curing of dental materials for decades and are now almost entirely replaced by modern light emitting diode light curing units (LED LCUs). Exactly 50 years ago, visible LEDs were invented. Nevertheless, it was not before the 1990s that LEDs were seriously considered by scientists or manufactures of commercial LCUs as light sources to photopolymerize dental composites and other dental materials. The objective of this review paper is to give an overview of the scientific development and state-of-the-art of LED photopolymerization of oral biomaterials. The materials science of LED LCU devices and dental materials photopolymerized with LED LCU, as well as advantages and limits of LED photopolymerization of oral biomaterials, are discussed. This is mainly based on a review of the most frequently cited scientific papers in international peer reviewed journals. The developments of commercial LED LCUs as well as aspects of their clinical use are considered in this review. The development of LED LCUs has progressed in steps and was made possible by (i) the invention of visible light emitting diodes 50 years ago; (ii) the introduction of high brightness blue light emitting GaN LEDs in 1994; and (iii) the creation of the first blue LED LCUs for the photopolymerization of oral biomaterials. The proof of concept of LED LCUs had to be demonstrated by the satisfactory performance of resin based restorative dental materials photopolymerized by these devices, before LED photopolymerization was generally accepted. Hallmarks of LED LCUs include a unique light emission spectrum, high curing efficiency, long life, low energy consumption and compact device form factor. By

  13. LED lamp power management system and method

    DOEpatents

    Gaines, James; Clauberg, Bernd; Van Erp, Josephus A. M.

    2013-03-19

    An LED lamp power management system and method including an LED lamp having an LED controller 58; a plurality of LED channels 60 operably connected to the LED controller 58, each of the plurality of LED channels 60 having a channel switch 62 in series with at least one shunted LED circuit 83, the shunted LED circuit 83 having a shunt switch 68 in parallel with an LED source 80. The LED controller 58 reduces power loss in one of the channel switch 62 and the shunt switch 68 when LED lamp electronics power loss (P.sub.loss) exceeds an LED lamp electronics power loss limit (P.sub.lim); and each of the channel switches 62 receives a channel switch control signal 63 from the LED controller 58 and each of the shunt switches 68 receives a shunt switch control signal 69 from the LED controller 58.

  14. Theoretical and experimental luminous characteristics of white LEDs composed of multiphosphors and near-UV LED for lighting

    NASA Astrophysics Data System (ADS)

    Uchida, Yuji; Taguchi, Tsunemasa

    2003-07-01

    We have performed theoretical studies on the luminous characeristics of white LED light source which composed of multi phosphors and near ultraviolet (UV) LED for general lighting. White LED source for general lighting applications requires the conditions that have high-flux, high luminous efficacy of radiation (> 100 lm/W) in addition to high color rendering index (Ra > 90) and variable color temperatures. Recently, we have proposed a novel type white LED based on multi phosphors and near UV LED system in order to high-Ra (>93). We will describe the excellent luminescence properties of white LED consisting of orange (O), yellow (Y), green (G) and blue (B) phosphor materials, and near UV LED. The color spectral contributions of individual phosphor-coated LED are theoretically analyzed using our multi LED lighting theory calculated the maximum luminous efficacy can be estimated to be approximately 300 lm/W having a high Ra of about 90 taking into account individual radiation spectrum. Illuminance distribution of white LED is in fairly good agreement with the experimental data.

  15. Selective-area nanoheteroepitaxy for light emitting diode (LED) applications

    NASA Astrophysics Data System (ADS)

    Wildeson, Isaac H.

    Over 20% of the electricity in the United States is consumed for lighting, and the majority of this energy is wasted as heat during the lighting process. A solid-state (or light emitting diode (LED)-based) light source has the potential of saving the United States billions of dollars in electricity and reducing megatons of global CO2 emissions annually. While white light LEDs are currently on the market with efficiencies that are superior to incandescent and fluorescent light sources, their high up-front cost is inhibiting mass adoption. One reason for the high cost is the inefficiency of green and amber LEDs that can used to make white light. The inefficiency of green and amber LEDs results in more of these chips being required, and thus a higher cost. Improvements in the performance of green and amber LEDs is also required in order to realize the full potential of solid-state lighting. Nanoheteroepitaxy is an interesting route towards achieving efficient green and amber LEDs as it resolves major challenges that are currently plaguing III-nitride LEDs such as high dislocation densities and limited active region critical thicknesses. A method for fabricating III-nitride nanopyramid LEDs is presented that employs conventional processing used in industry. The present document begins with an overview of the current challenges in III-nitride LEDs and the benefits of nanoheteroepitaxy. A process for controlled selective-area growth of nanopyramid LEDs by organometallic vapor phase epitaxy has been developed throughout the course of this work. Dielectric templates used for the selective-area growth are patterned by two methods, namely porous anodic alumina and electron-beam lithography. The dielectric templates serve as efficient dislocation filters; however, planar defects are initiated during lower temperature growth on the nanopyramids. The quantum wells outline six semipolar planes that form each hexagonal pyramid. Quantum wells grown on these semipolar planes

  16. Comparative performance analysis of shunt and series passive filter for LED lamp

    NASA Astrophysics Data System (ADS)

    Sarwono, Edi; Facta, Mochammad; Handoko, Susatyo

    2018-03-01

    Light Emitting Diode lamp or LED lamp nowadays is widely used by consumers as a new innovation in the lighting technologies due to its energy saving for low power consumption lamps for brighter light intensity. How ever, the LED lamp produce an electric pollutant known as harmonics. The harmonics is generated by rectifier as part of LED lamp circuit. The present of harmonics in current or voltage has made the source waveform from the grid is distorted. This distortion may cause inacurrate measurement, mall function, and excessive heating for any element at the grid. This paper present an analysis work of shunt and series filters to suppress the harmonics generated by the LED lamp circuit. The work was initiated by conducting several tests to investigate the harmonic content of voltage and currents. The measurements in this work were carried out by using HIOKI Power Quality Analyzer 3197. The measurement results showed that the harmonics current of tested LED lamps were above the limit of IEEE standard 519-2014. Based on the measurement results shunt and series filters were constructed as low pass filters. The bode analysis were appled during construction and prediction of the filters performance. Based on experimental results, the application of shunt filter at input side of LED lamp has reduced THD current up to 88%. On the other hand, the series filter has significantly reduced THD current up to 92%.

  17. Marginal integrity of resin composite restorations restored with PPD initiatorcontaining resin composite cured by QTH, monowave and polywave LED units.

    PubMed

    Bortolotto, Tissiana; Betancourt, Francisco; Krejci, Ivo

    2016-12-01

    This study evaluated the influence of curing devices on marginal adaptation of cavities restored with self-etching adhesive containing CQ and PPD initiators and hybrid composite. Twenty-four class V (3 groups, n=8) with margins located on enamel and dentin were restored with Clearfil S3 Bond and Clearfil APX PLT, light-cured with a monowave LED, multiwave LED and halogen light-curing unit (LCU). Marginal adaptation was evaluated with SEM before/after thermo-mechanical loading (TML). On enamel, significantly lower % continuous margins (74.5±12.6) were found in group cured by multiwave LED when compared to monowave LED (87.6±9.5) and halogen LCU (94.4±9.1). The presence of enamel and composite fractures was significantly higher in the group light-cured with multiwave LED, probably due to an increased materials' friability resulted from an improved degree of cure. The clinician should aware that due to a distinct activation of both initiators, marginal quality may be influenced on the long-term.

  18. Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting in Leavenworth, KS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myer, Michael; Kinzey, Bruce R.; Curry, Ku'uipo

    2011-05-06

    This report describes the process and results of a demonstration of solid-state lighting (SSL) technology in a commercial parking lot lighting application, under the U.S. Department of Energy (DOE) Solid-State Lighting Technology GATEWAY Demonstration Program. The parking lot is for customers and employees of a Walmart Supercenter in Leavenworth, Kansas and this installation represents the first use of the LED Parking Lot Performance Specification developed by the DOE’s Commercial Building Energy Alliance. The application is a parking lot covering more than a half million square feet, lighted primarily by light-emitting diodes (LEDs). Metal halide wall packs were installed along themore » building facade. This site is new construction, so the installed baseline(s) were hypothetical designs. It was acknowledged early on that deviating from Walmart’s typical design would reduce the illuminance on the site. Walmart primarily uses 1000W pulse-start metal halide (PMH) lamps. In order to provide a comparison between both typical design and a design using conventional luminaires providing a lower illuminance, a 400W PMH design was also considered. As mentioned already, the illuminance would be reduced by shifting from the PMH system to the LED system. The Illuminating Engineering Society of North America (IES) provides recommended minimum illuminance values for parking lots. All designs exceeded the recommended illuminance values in IES RP-20, some by a wider margin than others. Energy savings from installing the LED system compared to the different PMH systems varied. Compared to the 1000W PMH system, the LED system would save 63 percent of the energy. However, this corresponds to a 68 percent reduction in illuminance as well. In comparison to the 400W PMH system, the LED system would save 44 percent of the energy and provide similar minimum illuminance values at the time of relamping. The LED system cost more than either of the PMH systems when comparing initial

  19. Demonstration Assessment of Light-Emitting Diode (LED) Roadway Lighting, I-35W Bridge, Minneapolis, Minnesota, Phase I Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kinzey, B. R.; Myer, M. A.

    2009-08-01

    On the I-35W Bridge in Minneapolis, Minnesota, the GATEWAY program conducted a two-phase demonstration of LED roadway lighting on the main span, which is one of the country's oldest continuously operated exterior LED lighting installations. The Phase I report provides an overview of initial project results including lighting performance, economic performance, and potential energy savings.

  20. Advances in LEDs for automotive applications

    NASA Astrophysics Data System (ADS)

    Bhardwaj, Jy; Peddada, Rao; Spinger, Benno

    2016-03-01

    High power LEDs were introduced in automotive headlights in 2006-2007, for example as full LED headlights in the Audi R8 or low beam in Lexus. Since then, LED headlighting has become established in premium and volume automotive segments and beginning to enable new compact form factors such as distributed low beam and new functions such as adaptive driving beam. New generations of highly versatile high power LEDs are emerging to meet these application needs. In this paper, we will detail ongoing advances in LED technology that enable revolutionary styling, performance and adaptive control in automotive headlights. As the standards which govern the necessary lumens on the road are well established, increasing luminance enables not only more design freedom but also headlight cost reduction with space and weight saving through more compact optics. Adaptive headlighting is based on LED pixelation and requires high contrast, high luminance, smaller LEDs with high-packing density for pixelated Matrix Lighting sources. Matrix applications require an extremely tight tolerance on not only the X, Y placement accuracy, but also on the Z height of the LEDs given the precision optics used to image the LEDs onto the road. A new generation of chip scale packaged (CSP) LEDs based on Wafer Level Packaging (WLP) have been developed to meet these needs, offering a form factor less than 20% increase over the LED emitter surface footprint. These miniature LEDs are surface mount devices compatible with automated tools for L2 board direct attach (without the need for an interposer or L1 substrate), meeting the high position accuracy as well as the optical and thermal performance. To illustrate the versatility of the CSP LEDs, we will show the results of, firstly, a reflector-based distributed low beam using multiple individual cavities each with only 20mm height and secondly 3x4 to 3x28 Matrix arrays for adaptive full beam. Also a few key trends in rear lighting and impact on LED light

  1. Transforming Care at the Bedside (TCAB): enhancing direct care and value-added care.

    PubMed

    Dearmon, Valorie; Roussel, Linda; Buckner, Ellen B; Mulekar, Madhuri; Pomrenke, Becky; Salas, Sheri; Mosley, Aimee; Brown, Stephanie; Brown, Ann

    2013-05-01

    The purpose of this study was to examine the effectiveness of a Transforming Care at the Bedside initiative from a unit perspective. Improving patient outcomes and nurses' work environments are the goals of Transforming Care at the Bedside. Transforming Care at the Bedside creates programs of change originating at the point of care and directly promoting engagement of nurses to transform work processes and quality of care on medical-surgical units. This descriptive comparative study draws on multiple data sources from two nursing units: a Transforming Care at the Bedside unit where staff tested, adopted and implemented improvement ideas, and a control unit where staff continued traditional practices. Change theory provided the framework for the study. Direct care and value-added care increased on Transforming Care at the Bedside unit compared with the control unit. Transforming Care at the Bedside unit decreased in incidental overtime. Nurses reported that the process challenged old ways of thinking and increased nursing innovations. Hourly rounding, bedside reporting and the use of pain boards were seen as positive innovations. Evidence supported the value-added dimension of the Transforming Care at the Bedside process at the unit level. Nurses recognized the significance of their input into processes of change. Transformational leadership and frontline projects provide a vehicle for innovation through application of human capital. © 2012 Blackwell Publishing Ltd.

  2. Person-centred care in nurse-led outpatient rheumatology clinics: Conceptualization and initial development of a measurement instrument.

    PubMed

    Bala, Sidona-Valentina; Forslind, Kristina; Fridlund, Bengt; Samuelson, Karin; Svensson, Björn; Hagell, Peter

    2018-06-01

    Person-centred care (PCC) is considered a key component of effective illness management and high-quality care. However, the PCC concept is underdeveloped in outpatient care. In rheumatology, PCC is considered an unmet need and its further development and evaluation is of high priority. The aim of the present study was to conceptualize and operationalize PCC, in order to develop an instrument for measuring patient-perceived PCC in nurse-led outpatient rheumatology clinics. A conceptual outpatient PCC framework was developed, based on the experiences of people with rheumatoid arthritis (RA), person-centredness principles and existing PCC frameworks. The resulting framework was operationalized into the PCC instrument for outpatient care in rheumatology (PCCoc/rheum), which was tested for acceptability and content validity among 50 individuals with RA attending a nurse-led outpatient clinic. The conceptual framework focuses on the meeting between the person with RA and the nurse, and comprises five interrelated domains: social environment, personalization, shared decision-making, empowerment and communication. Operationalization of the domains into a pool of items generated a preliminary PCCoc/rheum version, which was completed in a mean (standard deviation) of 5.3 (2.5) min. Respondents found items easy to understand (77%) and relevant (93%). The Content Validity Index of the PCCoc/rheum was 0.94 (item level range, 0.87-1.0). About 80% of respondents considered some items redundant. Based on these results, the PCCoc/rheum was revised into a 24-item questionnaire. A conceptual outpatient PCC framework and a 24-item questionnaire intended to measure PCC in nurse-led outpatient rheumatology clinics were developed. The extent to which the questionnaire represents a measurement instrument remains to be tested. Copyright © 2018 John Wiley & Sons, Ltd.

  3. Developing Successful International Faculty Led Program

    ERIC Educational Resources Information Center

    Fabregas Janeiro, Maria G.; Fabre, Ricardo Lopez; Rosete, Rodrigo Tello

    2012-01-01

    Faculty Led Programs are study abroad experiences led by university professors. Faculty Led Programs are considered as an opportunity for college students, especially in the United States to attend a short-term international experience (Mills, 2010). Faculty Led Program is an international experience which is different from the traditional…

  4. CALiPER Report 22.1: Photoelectric Performance of LED MR16 Lamps

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Royer, Michael P.; Poplawski, Michael E.; Brown, Charles C.

    This report is a follow-up to CALiPER Application Summary Report 22, which investigated the photometric performance of LED MR16 lamps. The initial report found that many of the LED MR16 lamps did not perform as required by ENERGY STAR based on their equivalency claims, although they generally did provide substantial efficacy advantages compared to halogen MR16 lamps. All testing was completed using laboratory power supplies, with all but one product tested at 12 V AC. In contrast, this report examined the photoelectric performance of the same set of lamps, using commercially available transformers and dimmers as well as laboratory powermore » supplies providing both AC and DC power.« less

  5. High-power LED package requirements

    NASA Astrophysics Data System (ADS)

    Wall, Frank; Martin, Paul S.; Harbers, Gerard

    2004-01-01

    Power LEDs have evolved from simple indicators into illumination devices. For general lighting applications, where the objective is to light up an area, white LED arrays have been utilized to serve that function. Cost constraints will soon drive the industry to provide a discrete lighting solution. Early on, that will mean increasing the power densities while quantum efficiencies are addressed. For applications such as automotive headlamps & projection, where light needs to be tightly collimated, or controlled, arrays of die or LEDs will not be able to satisfy the requirements & limitations defined by etendue. Ultimately, whether a luminaire requires a small source with high luminance, or light spread over a general area, economics will force the evolution of the illumination LED into a compact discrete high power package. How the customer interfaces with this new package should be an important element considered early on in the design cycle. If an LED footprint of adequate size is not provided, it may prove impossible for the customer, or end user, to get rid of the heat in a manner sufficient to prevent premature LED light output degradation. Therefore it is critical, for maintaining expected LED lifetime & light output, that thermal performance parameters be defined, by design, at the system level, which includes heat sinking methods & interface materials or methdology.

  6. An inexpensive Arduino-based LED stimulator system for vision research.

    PubMed

    Teikari, Petteri; Najjar, Raymond P; Malkki, Hemi; Knoblauch, Kenneth; Dumortier, Dominique; Gronfier, Claude; Cooper, Howard M

    2012-11-15

    Light emitting diodes (LEDs) are being used increasingly as light sources in life sciences applications such as in vision research, fluorescence microscopy and in brain-computer interfacing. Here we present an inexpensive but effective visual stimulator based on light emitting diodes (LEDs) and open-source Arduino microcontroller prototyping platform. The main design goal of our system was to use off-the-shelf and open-source components as much as possible, and to reduce design complexity allowing use of the system to end-users without advanced electronics skills. The main core of the system is a USB-connected Arduino microcontroller platform designed initially with a specific emphasis on the ease-of-use creating interactive physical computing environments. The pulse-width modulation (PWM) signal of Arduino was used to drive LEDs allowing linear light intensity control. The visual stimulator was demonstrated in applications such as murine pupillometry, rodent models for cognitive research, and heterochromatic flicker photometry in human psychophysics. These examples illustrate some of the possible applications that can be easily implemented and that are advantageous for students, educational purposes and universities with limited resources. The LED stimulator system was developed as an open-source project. Software interface was developed using Python with simplified examples provided for Matlab and LabVIEW. Source code and hardware information are distributed under the GNU General Public Licence (GPL, version 3). Copyright © 2012 Elsevier B.V. All rights reserved.

  7. Some quantitative aspects of temporary blinding from high brightness LEDs

    NASA Astrophysics Data System (ADS)

    Reidenbach, Hans-Dieter

    2007-02-01

    According to the new European Directive on Artificial Optical Radiation (2006/25/EC) the employer has to determine the exposure and the assessment of risks, i.e. workers shall not be exposed above the exposure limit values, which are based on various ICNIRP guidelines. In addition, the employer shall give particular attention, when carrying out the risk assessment, to any indirect effects amongst others such as temporary blinding. Since up to now no quantitative values exist in order to rank or classify artificial optical sources and its associated capability of temporary blinding, we have investigated some aspects of glare and dazzling from a high-brightness LED (HB-LED). With such a single device and an array consisting of 80 HB-LEDs we have found in a previous investigation that the frequency of the blink reflex exceeds the one achieved with laser belonging to class 2 according to the international standard IEC 60825-1, however is less than about 50 %. The size of an after-image as a function of time and the visual acuity after an exposure from a white high-brightness LED has been investigated in detail with 3 test persons. The results have shown that the size of an after-image on the human retina remains nearly constant with a slight decrease over a time duration of about 12 minutes, whereas the initial visual acuity is recovered within 30 up to 60 seconds. Linear and exponential regression descriptions are given for both characteristics.

  8. Light Emitting Diode (LED)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    A special lighting technology was developed for space-based commercial plant growth research on NASA's Space Shuttle. Surgeons have used this technology to treat brain cancer on Earth, in two successful operations. The treatment technique called photodynamic therapy, requires the surgeon to use tiny pinhead-size Light Emitting Diodes (LEDs) (a source releasing long wavelengths of light) to activate light-sensitive, tumor-treating drugs. Laser light has been used for this type of surgery in the past, but the LED light illuminates through all nearby tissues, reaching parts of a tumor that shorter wavelengths of laser light carnot. The new probe is safer because the longer wavelengths of light are cooler than the shorter wavelengths of laser light, making the LED less likely to injure normal brain tissue near the tumor. It can also be used for hours at a time while still remaining cool to the touch. The LED probe consists of 144 tiny pinhead-size diodes, is 9-inches long, and about one-half-inch in diameter. The small balloon aids in even distribution of the light source. The LED light source is compact, about the size of a briefcase, and can be purchased for a fraction of the cost of a laser. The probe was developed for photodynamic cancer therapy by the Marshall Space Flight Center under a NASA Small Business Innovative Research program grant.

  9. Investigating the LED's dark side. Novel LED Model Offers New Insights

    DOE PAGES

    Chow, Weng Wah

    2014-07-01

    A revolution in lighting is well on its way. Rewind the clock a year or so and the prices of LED bulbs made many shoppers wince. But now it is possible to get a high-quality 60 W equivalent for well under $10, and that’s allowing sales of LED bulbs incorporating chips from the likes of Cree and Philips Lumileds to take off. Although these solid-state bulbs are much more pricey than incandescents, which have largely disappeared from shelves due to legislation, they more than make up for that additional up-front cost with a substantial trimming of the electricity bill. Itmore » is a more tricky decision, however, whether it makes more sense to buy an LED bulb or a cheaper compact fluorescent (CFL). In terms of durability, adaptability and environmental impact, the solid-state bulb is the clear winner. But both types of light are similar in the efficiency stakes, and thus the running costs.« less

  10. Peer-led versus teacher-led AIDS education for female high-school students in Yazd, Islamic Republic of Iran.

    PubMed

    Baghianimoghadam, M H; Forghani, H; Zolghadr, R; Rahaei, Z; Khani, P

    2012-04-01

    Peer-led programmes on AIDS prevention have shown a good level of effectiveness when tested among high-risk populations. This study compared peer-led and teacher-led methods of education about HIV/AIDS among female high-school students in Yazd city, Islamic Republic of Iran. In 2009 students in 3 high schools were trained by their classmates (peer-led), by the research team (teacher-led) or had no education (controls); 180 students completed a specially designed questionnaire based on the health belief model, before and after the intervention. Post-intervention mean knowledge scores increased 2-fold in the peer-led group, and this was significantly higher than the increase in the teacher-led group scores (1.5-fold). Control group scores were unchanged. In the peer-led programme all of the components of the model were significantly improved whereas in the teacher-led programme, only perceived severity and perceived barriers scored significantly higher after the intervention.

  11. A new approach to preparation of standard LEDs for luminous intensity and flux measurement of LEDs

    NASA Astrophysics Data System (ADS)

    Park, Seung-Nam; Park, Seongchong; Lee, Dong-Hoon

    2006-09-01

    This work presents an alternative approach for preparing photometric standard LEDs, which is based on a novel functional seasoning method. The main idea of our seasoning method is simultaneously monitoring the light output and the junction voltage to obtain quantitative information on the temperature dependence and the aging effect of the LED emission. We suggested a general model describing the seasoning process by taking junction temperature variation and aging effect into account and implemented a fully automated seasoning facility, which is capable of seasoning 12 LEDs at the same time. By independent measurements of the temperature dependence, we confirmed the discrepancy of the theoretical model to be less than 0.5 % and evaluate the uncertainty contribution of the functional seasoning to be less than 0.5 % for all the seasoned samples. To demonstrate assigning the reference value to a standard LED, the CIE averaged LED intensity (ALI) of the seasoned LEDs was measured with a spectroradiometer-based instrument and the measurement uncertainty was analyzed. The expanded uncertainty of the standard LED prepared by the new approach amounts to be 4 % ~ 5 % (k=2) depending on color without correction of spectral stray light in the spectroradiometer.

  12. LED lighting efficacy: Status and directions

    DOE PAGES

    Morgan Pattison, Paul; Hansen, Monica; Tsao, Jeffrey Y.

    2017-12-28

    A monumental shift from conventional lighting technologies (incandescent, fluorescent, high intensity discharge) to LED lighting is currently transpiring. The primary driver for this shift has been energy and associated cost savings. LED lighting is now more efficacious than any of the conventional lighting technologies with room to still improve. Near term, phosphor converted LED packages have the potential for efficacy improvement from 160 lm/W to 255 lm/W. Longer term, color-mixed LED packages have the potential for efficacy levels conceivably as high as 330 lm/W, though reaching these performance levels requires breakthroughs in green and amber LED efficiency. LED package efficacymore » sets the upper limit to luminaire efficacy, with the luminaire containing its own efficacy loss channels. In this paper, based on analyses performed through the U.S. Department of Energy Solid State Lighting Program, various LED and luminaire loss channels are elucidated, and critical areas for improvement identified. Beyond massive energy savings, LED technology enables a host of new applications and added value not possible or economical with previous lighting technologies. These include connected lighting, lighting tailored for human physiological responses, horticultural lighting, and ecologically conscious lighting. Finally, none of these new applications would be viable if not for the high efficacies that have been achieved, and are themselves just the beginning of what LED lighting can do.« less

  13. LED lighting efficacy: Status and directions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Morgan Pattison, Paul; Hansen, Monica; Tsao, Jeffrey Y.

    A monumental shift from conventional lighting technologies (incandescent, fluorescent, high intensity discharge) to LED lighting is currently transpiring. The primary driver for this shift has been energy and associated cost savings. LED lighting is now more efficacious than any of the conventional lighting technologies with room to still improve. Near term, phosphor converted LED packages have the potential for efficacy improvement from 160 lm/W to 255 lm/W. Longer term, color-mixed LED packages have the potential for efficacy levels conceivably as high as 330 lm/W, though reaching these performance levels requires breakthroughs in green and amber LED efficiency. LED package efficacymore » sets the upper limit to luminaire efficacy, with the luminaire containing its own efficacy loss channels. In this paper, based on analyses performed through the U.S. Department of Energy Solid State Lighting Program, various LED and luminaire loss channels are elucidated, and critical areas for improvement identified. Beyond massive energy savings, LED technology enables a host of new applications and added value not possible or economical with previous lighting technologies. These include connected lighting, lighting tailored for human physiological responses, horticultural lighting, and ecologically conscious lighting. Finally, none of these new applications would be viable if not for the high efficacies that have been achieved, and are themselves just the beginning of what LED lighting can do.« less

  14. Kansas highway LED illumination manual : a guide for the use of LED lighting systems.

    DOT National Transportation Integrated Search

    2015-12-01

    The research project was aimed to assist the Kansas Department of Transportation (KDOT) in the development of a Highway LED Illumination Manual for guiding the upcoming implementation of successful LED roadway lighting systems in Kansas to replace th...

  15. Nonuniformity of carrier injection and the degradation of blue LEDs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bochkareva, N. I.; Efremov, A. A.; Rebane, Yu. T.

    The distribution of electroluminescence (EL) intensity over the area and in the course of time before and after the optical degradation of blue InGaN/GaN LEDs is studied. Current-voltage characteristics have been recorded. It is found that the initially bright luminescence near the region of metallization of the p-contact turns weak after the degradation of an LED. The time delay of {approx}20-40 ns is observed in the distribution of EL intensity over the area of LEDs after their degradation. We suppose that a rise in the excess current after degradation is due to the density increasing of the InGaN/GaN interface statesmore » and the formation of an electrical dipole, which lowers the potential barriers in p-GaN and n-GaN layers. The corresponding increase of capacitance leads to a time delay in the spreading of the injection current and in the distribution of the emission brightness over the area. The lateral nonuniformity of the carrier injection into the quantum, well before and after optical degradation, is attributed to diffusion and electromigration of hydrogen, induced by mechanical stress. The metallization of the p-contact may be the source of mechanical stress.« less

  16. Interprofessional education through service-learning: lessons from a student-led free clinic.

    PubMed

    Farlow, Janice L; Goodwin, Charles; Sevilla, Javier

    2015-05-01

    The academic community must replicate and strengthen existing models for interprofessional education (IPE) to meet widespread calls for team-based patient-centered care. One effective but under-explored possibility for IPE is through student-led clinics, which now exist in the majority of medical schools. This short report presents the Indiana University Student Outreach Clinic (IU-SOC), which involves seven different professional programs across three institutions, as a model for how IPE can be delivered formally through service learning. Lessons learned, such as nurturing an intentional interprofessional program, structured orientation and reflection, and resource and knowledge sharing between the clinic and academic institutions, can be applied to all student-led clinics, but also can inform other IPE initiatives in health professional curricula.

  17. 77 FR 58406 - Certain LED Photographic Lighting Devices and Components Thereof; Notice of Request for...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-20

    ...Notice is hereby given that the presiding administrative law judge (``ALJ'') has issued a Final Initial Determination and Recommended Determination on Remedy and Bonding in the above-captioned investigation. The Commission is soliciting comments on public interest issues raised by the recommended relief, specifically a general exclusion order against certain LED photographic lighting devices and components thereof. The ALJ alternatively recommended a limited exclusion order against certain LED photographic lighting devices and components thereof manufactured or sold by the respondents found in violation of 19 U.S.C. 1337.

  18. Refrigerated display case lighting with LEDs

    NASA Astrophysics Data System (ADS)

    Raghavan, Ramesh; Narendran, Nadarajah

    2002-11-01

    The rapid development of high brightness light emitting diodes (LEDs) has triggered many applications, especially in the area of display lighting. This paper focuses on the application of white LEDs in refrigerated display cases. The fluorescent lighting presently used in commercial refrigerators is inefficient in the application and also it provides poor lighting for merchandising. A laboratory human factors experiment was conducted to assess the preference for the different lighting systems, namely, fluorescent and LED. Two refrigerated display cases, one with the traditional fluorescent lighting system and the other with a prototype LED lighting system, were placed side-by-side in a laboratory setting. Illuminance measurements made within the two display cases showed that the lighting was more uniform with the LED system compared to the traditional fluorescent system. Sixteen human subjects participated in this study and rated their preference for the two lighting systems. The results show that human subjects strongly preferred the display case with the LED lighting. The authors of this manuscript believe a field study would be greatly beneficial to further confirm these results and to understand the relationship between preference and sales. Considering the luminous efficacy of white LEDs presently available in the marketplace, it is possible to develop a LED based lighting system for commercial refrigerators that is competitive with fluorescent lighting system in terms of energy use. The LED based lighting would provide better lighting than traditional fluorescent lighting.

  19. LED Illuminators for the SNAP Calibration

    NASA Astrophysics Data System (ADS)

    Misra, Amit; Baptista, B.; Mufson, S.; Mostek, N.

    2007-12-01

    The Supernova Acceleration Probe, or SNAP, is a proposed satellite mission that will study dark energy to better understand what is driving the universe's accelerated expansion. One of the goals of SNAP is to control systematic color uncertainties to less than 2%. The work described here is directed at the development of a flight calibration illumination system for SNAP that minimizes systematic errors in color. The system is based on LEDs as the illumination lamps. LEDs are compact, long-lived, and low power illuminators, which make them attractive for space missions lasting several years. This poster discusses optical measurements of pulsed, thermally controlled LEDs obtained from commercial vendors. Measurements over short (over the span of one day) and long (over the span of weeks) time scales have shown that the irradiance of the LEDs we tested is constant at the 0.3% level. In these measurements we paid particular attention to the influence of junction heating. Measurements of LED irradiance versus the duty cycle of the pulsed LED show that in general the LED irradiance increases as the junction temperature increases. Additionally, the FWHM of the spectrum also increases as the temperature increases. However, measurements of LED irradiance versus temperature as regulated a by a thermal controller circuit, show that the LED irradiance decreases as the temperature increases. This work has been supported by the National Science Foundation under grant AST-0452975 (REU-Site to Indiana U.).

  20. Ontario's Student Voice Initiative

    ERIC Educational Resources Information Center

    Courtney, Jean

    2014-01-01

    This article describes in some detail aspects of the Student Voice initiative funded and championed by Ontario's Ministry of Education since 2008. The project enables thousands of students to make their voices heard in meaningful ways and to participate in student-led research. Some students from grades 7 to 12 become members of the Student…

  1. R&D100: LED Pulser

    ScienceCinema

    Pickett, Lyle; Manin, Julien; Eagle, Ethan

    2018-06-12

    A Sandia National Laboratories' light emitting diode (LED) driver is generating light pulses with shorter duration higher repetition frequency and higher brightness than anything on the market. The Sandia LED Pulser uses custom electronic circuitry to drive high-power LEDs to generate short, bright, high frequency light pulses. A single device can emit up to four different colors - each with independent pulse timing - crucial for light-beam forming in many optical applications and is more economical than current light sources such as lasers.

  2. Light Emitting Diodes (LEDs)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    A special lighting technology was developed for space-based commercial plant growth research on NASA's Space Shuttle. Surgeons have used this technology to treat brain cancer on Earth, in two successful operations. The treatment technique, called Photodynamic Therapy, requires the surgeon to use tiny, pinhead-size Light Emitting Diodes (LEDs) (a source that releases long wavelengths of light ) to activate light-sensitive, tumor-treating drugs. 'A young woman operated on in May 1999 has fully recovered with no complications and no evidence of the tumor coming back,' said Dr. Harry Whelan, a pediatric neurologist at the Medical Hospital of Wisconsin in Milwaukee. Laser light has been used for this type of surgery in the past, but the LED light illuminates through all nearby tissues, reaching parts of a tumor that shorter wavelengths of laser light carnot. The new probe is safer because the longer wavelengths of light are cooler than the shorter wavelengths of laser light, making the LED less likely to injure normal brain tissue near the tumor. It can be used for hours at a time while still remaining cool to the touch. The LED light source is compact, about the size of a briefcase, and can be purchased for a fraction of the cost of a laser. The LEDs, developed and managed by NASA's Marshall Space Flight Center, have been used on seven Space Shuttle flights inside the Microgravity Astroculture Facility. This technology has also been successfully used to further commercial research in crop growth.

  3. Miniature LED endoilluminators for vitreoretinal surgery

    NASA Astrophysics Data System (ADS)

    Hessling, M.; Koelbl, P. S.; Lingenfelder, C.; Koch, F.

    2015-07-01

    Two innovative approaches for intraocular illumination during vitreoretinal surgery by application of white LEDs are being developed. Both techniques are less harmful to the patient, more convenient for the surgeon and smaller and cheaper compared to conventional illumination by Xenon light sources and optical fibers. These two novel approaches are: I) The miniature LED chandelier endoilluminator consisting of a single white LED with a "light probe" on top of the LED housing that fits in a small incision in the wall of the eye. II) The alternative transscleral LED endoilluminator is integrated into an eye speculum that presses the flat LED top against the eye. The intraocular space is only illuminated by light transmitted through the sclera. In contrast to conventional illumination techniques for vitreoretinal surgery no incision is necessary. Both approaches are evaluated with regard to potential photochemical and thermal risks for the patient's retina and they are tested on porcine eyes.

  4. Projecting LED product life based on application

    NASA Astrophysics Data System (ADS)

    Narendran, Nadarajah; Liu, Yi-wei; Mou, Xi; Thotagamuwa, Dinusha R.; Eshwarage, Oshadhi V. Madihe

    2016-09-01

    LED products have started to displace traditional light sources in many lighting applications. One of the commonly claimed benefits for LED lighting products is their long useful lifetime in applications. Today there are many replacement lamp products using LEDs in the marketplace. Typically, lifetime claims of these replacement lamps are in the 25,000-hour range. According to current industry practice, the time for the LED light output to reach the 70% value is estimated according to IESNA LM-80 and TM-21 procedures and the resulting value is reported as the whole system life. LED products generally experience different thermal environments and switching (on-off cycling) patterns when used in applications. Current industry test methods often do not produce accurate lifetime estimates for LED systems because only one component of the system, namely the LED, is tested under a continuous-on burning condition without switching on and off, and because they estimate for only one failure type, lumen depreciation. The objective of the study presented in this manuscript was to develop a test method that could help predict LED system life in any application by testing the whole LED system, including on-off power cycling with sufficient dwell time, and considering both failure types, catastrophic and parametric. The study results showed for the LED A-lamps tested in this study, both failure types, catastrophic and parametric, exist. The on-off cycling encourages catastrophic failure, and maximum operating temperature influences the lumen depreciation rate and parametric failure time. It was also clear that LED system life is negatively affected by on-off switching, contrary to commonly held belief. In addition, the study results showed that most of the LED systems failed catastrophically much ahead of the LED light output reaching the 70% value. This emphasizes the fact that life testing of LED systems must consider catastrophic failure in addition to lumen depreciation, and

  5. Perceived Learning Effectiveness of a Course Facebook Page: Teacher-Led versus Student-Led Approach

    ERIC Educational Resources Information Center

    Tugrul, Tugba Orten

    2017-01-01

    This research aims to compare the perceived effectiveness of teacher-led and student-led content management approaches embraced in a course Facebook page designed to enhance traditional classroom learning. Eighty-five undergraduate marketing course students voluntarily completed a questionnaire composed of two parts; a depiction of a course…

  6. Standardization of UV LED measurements

    NASA Astrophysics Data System (ADS)

    Eppeldauer, G. P.; Larason, T. C.; Yoon, H. W.

    2015-09-01

    Traditionally used source spectral-distribution or detector spectral-response based standards cannot be applied for accurate UV LED measurements. Since the CIE standardized rectangular-shape spectral response function for UV measurements cannot be realized with small spectral mismatch when using filtered detectors, the UV measurement errors can be several times ten percent or larger. The UV LEDs produce broadband radiation and both their peaks or spectral bandwidths can change significantly. The detectors used for the measurement of these LEDs also have different spectral bandwidths. In the discussed example, where LEDs with 365 nm peak are applied for fluorescent crack-recognition using liquid penetrant (non-destructive) inspection, the broadband radiometric LED (signal) measurement procedure is standardized. A UV LED irradiance-source was calibrated against an FEL lamp standard to determine its spectral irradiance. The spectral irradiance responsivity of a reference UV meter was also calibrated. The output signal of the reference UV meter was calculated from the spectral irradiance of the UV source and the spectral irradiance responsivity of the reference UV meter. From the output signal, both the integrated irradiance (in the reference plane of the reference meter) and the integrated responsivity of the reference meter were determined. Test UV meters calibrated for integrated responsivity against the reference UV meter, can be used to determine the integrated irradiance from a field UV source. The obtained 5 % (k=2) measurement uncertainty can be decreased when meters with spectral response close to a constant value are selected.

  7. Study and Implementation of White Power-LED Based Indoor Lighting Application for the Healthcare Sector

    NASA Astrophysics Data System (ADS)

    Chakraborty, A.; Ganguly, R.

    With the current technological growth in the field of device fabrication, white power-LED's are available for solid state lighting applications. This is a paradigm shift from electrical lighting to electronic lighting. The implemented systems are showing some promise by saving a considerable amount of energy as well as providing a good and acceptable illumination level. However, the `useful life' of such devices is an important parameter. If the proper device is not chosen, the desired reliability and performance will not be obtained. In the present work, different parameters associated with reliability of such LED's are studied. Four different varieties of LED's are put to test the `useful life' as per IESNA LM 79 standard. From the results obtained, the proper LED is chosen for further application. Subsequently, lighting design is done for a hospital waiting room (indoor application) with 24 × 7 lighting requirements for replacement of existing CFLs there. The calculations show that although the initial cost is higher for LED based lighting, yet the savings on energy and replacement of the lamp results in a payback time of less than a year.

  8. White LED sources for vehicle forward lighting

    NASA Astrophysics Data System (ADS)

    Van Derlofske, John F.; McColgan, Michele W.

    2002-11-01

    Considerations for the use of white light emitting diode (LED) sources to produce illumination for automotive forward lighting is presented. Due to their reliability, small size, lower consumption, and lower heat generation LEDs are a natural choice for automotive lighting systems. Currently, LEDs are being sucessfully employed in most vehicle lighting applications. In these applications the light levels, distributions, and colors needed are achievable by present LED technologies. However, for vehicle white light illumination applications LEDs are now only being considered for low light level applications, such as back-up lamps. This is due to the relatively low lumen output that has been available up to now in white LEDs. With the advent of new higher lumen packages, and with the promise of even higher light output in the near future, the use of white LEDs sources for all vehicle forward lighting applications is beginning to be considered. Through computer modeling and photometric evaluation this paper examines the possibilities of using currently available white LED technology for vehicle headlamps. It is apparent that optimal LED sources for vehicle forward lighting applications will be constructed with hereto undeveloped technology and packaging configurations. However, the intent here in exploring currently available products is to begin the discussion on the design possibilities and significant issues surrounding LEDs in order to aid in the design and development of future LED sources and systems. Considerations such as total light output, physical size, optical control, power consumption, color appearance, and the effects of white LED spectra on glare and peripheral vision are explored. Finally, conclusions of the feasibility of current LED technology being used in these applications and recommendations of technology advancements that may need to occur are made.

  9. Life of LED-Based White Light Sources

    NASA Astrophysics Data System (ADS)

    Narendran, Nadarajah; Gu, Yimin

    2005-09-01

    Even though light-emitting diodes (LEDs) may have a very long life, poorly designed LED lighting systems can experience a short life. Because heat at the p-n-junction is one of the main factors that affect the life of the LED, by knowing the relationship between life and heat, LED system manufacturers can design and build long-lasting systems. In this study, several white LEDs from the same manufacturer were subjected to life tests at different ambient temperatures. The exponential decay of light output as a function of time provided a convenient method to rapidly estimate life by data extrapolation. The life of these LEDs decreases in an exponential manner with increasing temperature. In a second experiment,several high-power white LEDs from different manufacturers were life-tested under similar conditions. Results show that the different products have significantly different life values.

  10. Peer-Led Nutrition Education Programs for School-Aged Youth: A Systematic Review of the Literature

    ERIC Educational Resources Information Center

    Yip, Calvin; Gates, Michelle; Gates, Allison; Hanning, Rhona M.

    2016-01-01

    To date, the impacts of school-based, peer-led nutrition education initiatives have not been summarized or assessed collectively. This review presents the current evidence, identifies knowledge gaps, and provides recommendations for future research. PubMed, Scopus, ERIC and Google Scholar were searched for refereed Canadian and American primary…

  11. EDITORIAL: LED light sources (light for the future) LED light sources (light for the future)

    NASA Astrophysics Data System (ADS)

    Grandjean, N.

    2010-09-01

    Generating white light from electricity with maximum efficacy has been a long quest since the first incandescent lamp was invented by Edison at the end of the 19th century. Nowadays, semiconductors are making reality the holy grail of converting electrons into photons with 100% efficiency and with colours that can be mixed for white light illumination. The revolution in solid-state lighting (SSL) dates to 1994 when Nakamura reported the first high-brightness blue LED based on GaN semiconductors. Then, white light was produced by simply combining a blue dye with a yellow phosphor. After more than a decade of intensive research the performance of white LEDs is quite impressive, beating by far the luminous efficacy of compact fluorescent lamps. We are likely close to replacing our current lighting devices by SSL lamps. However, there are still technological and fabrication cost issues that could delay large market penetration of white LEDs. Interestingly, SSL may create novel ways of using light that could potentially limit electricity saving. Whatever the impact of SSL, it will be significant on our daily life. The purpose of this special cluster issue is to produce a snapshot of the current situation of SSL from different viewing angles. In an introductory paper, Tsao and co-workers from Sandia National Laboratories, present an energy-economics perspective of SSL considering societal changes and SSL technology evolution. In a second article, Narukawa et al working at Nichia Corporation—the pioneer and still the leading company in SSL—describe the state of the art of current research products. They demonstrate record performance with white LEDs exhibiting luminous efficacy of 183 lm W-1 at high-current injection. Then, a series of topical papers discuss in detail various aspects of the physics and technology of white LEDs Carrier localization in InGaN quantum wells has been considered the key to white LEDs' success despite the huge density of defects. A

  12. A Clinical Nurse Specialist-Led Interprofessional Quality Improvement Project to Reduce Hospital-Acquired Pressure Ulcers.

    PubMed

    Fabbruzzo-Cota, Christina; Frecea, Monica; Kozell, Kathryn; Pere, Katalin; Thompson, Tamara; Tjan Thomas, Julie; Wong, Angela

    2016-01-01

    The purpose of this clinical nurse specialist-led interprofessional quality improvement project was to reduce hospital-acquired pressure ulcers (HAPUs) using evidence-based practice. Hospital-acquired pressure ulcers (PUs) have been linked to morbidity, poor quality of life, and increasing costs. Pressure ulcer prevention and management remain a challenge for interprofessional teams in acute care settings. Hospital-acquired PU rate is a critical nursing quality indicator for healthcare organizations and ties directly with Mount Sinai Hospital's (MSH's) mission and vision, which mandates providing the highest quality care to patients and families. This quality improvement project, guided by the Donabedian model, was based on the Registered Nurses' Association of Ontario Best Practice Guideline Risk Assessment & Prevention of Pressure Ulcers. A working group was established to promote evidence-based practice for PU prevention. Initiatives such as documentation standardization, development of staff education and patient and family educational resources, initiation of a hospital-wide inventory for support surfaces, and procurement of equipment were implemented to improve PU prevention and management across the organization. An 80% decrease in HAPUs has been achieved since the implementation of best practices by the Best Practice Guideline Pressure Ulcer working group. The implementation of PU prevention strategies led to a reduction in HAPU rates. The working group will continue to work on building interprofessional awareness and collaboration in order to prevent HAPUs and promote an organizational culture that supports staff development, teamwork and communication. This quality improvement project is a successful example of an interprofessional clinical nurse specialist-led initiative that impacts patient/family and organization outcomes through the identification and implementation of evidence-based nursing practice.

  13. LED luminaire longevity strategy models comparison

    NASA Astrophysics Data System (ADS)

    Lemieux, Hugo; Thibault, Simon; Martel, Alain A.

    2010-08-01

    As energy efficiency becomes more and more important, light-emitting diodes (LEDs) are a promising alternative to traditional lighting. Indeed, the energy efficiency of LEDs is still improving as their luminosity is modulated by current. Moreover, for applications such as exterior lamp posts, their small size, directionality, colors and high frequency response allow to combine them and provide design possibilities which are impossible with any other light source. However, as any lamp, LEDs have a lumen depreciation which is a function of both current and temperature. Thus, to take advantage of the full characteristics of LEDs, LED luminaire longevity strategies must be carefully studied and planned, especially since the IES and CIE guidelines state clearly that the luminaire must maintain the rated recommended light level until the end of the system's operating life. The recommended approach for LED luminaire specification is therefore to use the end-of-life light level when evaluating the luminaire. Different power supply strategies have been simulated to determine which one maximizes energy saving and lifetime. With these results, it appears that active control can save at least 25% in energy, but the best strategy cannot be determined because of uncertainties in luminosity degradation models.

  14. Side-emitting illuminators using LED sources

    NASA Astrophysics Data System (ADS)

    Zhao, Feng; Van Derlofske, John F.

    2003-11-01

    This study investigates illuminators composed of light emitting diode (LED) array sources and side-emitting light guides to provide efficient general illumination. Specifically, new geometries are explored to increase the efficiency of current systems while maintaining desired light distribution. LED technology is already successfully applied in many illumination applications, such as traffic signals and liquid crystal display (LCD) backlighting. It provides energy-efficient, small-package, long-life, and color-adjustable illumination. However, the use of LEDs in general illumination is still in its early stages. Current side-emitting systems typically use a light guide with light sources at one end, an end-cap surface at the other end, and light releasing sidewalls. This geometry introduces efficiency loss that can be as high as 40%. The illuminators analyzed in this study use LED array sources along the longitude of a light guide to increase the system efficiency. These new geometries also provide the freedom of elongating the system without sacrificing system efficiency. In addition, alternative geometries can be used to create white light with monochromatic LED sources. As concluded by this study, the side-emitting illuminators using LED sources gives the possibility of an efficient, distribution-controllable linear lighting system.

  15. Comparison of midwife-led and consultant-led care of healthy women at low risk of childbirth complications in the Republic of Ireland: a randomised trial

    PubMed Central

    2011-01-01

    Background No midwifery-led units existed in Ireland before 2004. The aim of this study was to compare midwife-led (MLU) versus consultant-led (CLU) care for healthy, pregnant women without risk factors for labour and delivery. Methods An unblinded, pragmatic randomised trial was designed, funded by the Health Service Executive (Dublin North-East). Following ethical approval, all women booking prior to 24 weeks of pregnancy at two maternity hospitals with 1,300-3,200 births annually in Ireland were assessed for trial eligibility.1,653 consenting women were centrally randomised on a 2:1 ratio to MLU or CLU care, (1101:552). 'Intention-to-treat' analysis was used to compare 9 key neonatal and maternal outcomes. Results No statistically significant difference was found between MLU and CLU in the seven key outcomes: caesarean birth (163 [14.8%] vs 84 [15.2%]; relative risk (RR) 0.97 [95% CI 0.76 to 1.24]), induction (248 [22.5%] vs 138 [25.0%]; RR 0.90 [0.75 to 1.08]), episiotomy (126 [11.4%] vs 68 [12.3%]; RR 0.93 [0.70 to 1.23]), instrumental birth (139 [12.6%] vs 79 [14.3%]; RR 0.88 [0.68 to 1.14]), Apgar scores < 8 (10 [0.9%] vs 9 [1.6%]; RR 0.56 [0.23 to 1.36]), postpartum haemorrhage (144 [13.1%] vs 75 [13.6%]; RR 0.96 [0.74 to 1.25]); breastfeeding initiation (616 [55.9%] vs 317 [57.4%]; RR 0.97 [0.89 to 1.06]). MLU women were significantly less likely to have continuous electronic fetal monitoring (397 [36.1%] vs 313 [56.7%]; RR 0.64 [0.57 to 0.71]), or augmentation of labour (436 [39.6%] vs 314 [56.9%]; RR 0.50 [0.40 to 0.61]). Conclusions Midwife-led care, as practised in this study, is as safe as consultant-led care and is associated with less intervention during labour and delivery. Trial registration number ISRCTN: ISRCTN14973283 PMID:22035427

  16. [LED lights in dermatology].

    PubMed

    Noé, C; Pelletier-Aouizerate, M; Cartier, H

    2017-04-01

    The use in dermatology of light-emitting diodes (LEDs) continues to be surrounded by controversy. This is due mainly to poor knowledge of the physicochemical phases of a wide range of devices that are difficult to compare to one another, and also to divergences between irrefutable published evidence either at the level of in vitro studies or at the cellular level, and discordant clinical results in a variety of different indications: rejuvenation, acne, wound healing, leg ulcers, and cutaneous inflammatory or autoimmune processes. Therapeutic LEDs can emit wavelengths ranging from the ultraviolet, through visible light, to the near infrared (247-1300 nm), but only certain bands have so far demonstrated any real value. We feel certain that if this article remains factual, then readers will have a different, or at least more nuanced, opinion concerning the use of such LED devices in dermatology. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  17. An evaluation of primary care led dementia diagnostic services in Bristol.

    PubMed

    Dodd, Emily; Cheston, Richard; Fear, Tina; Brown, Ellie; Fox, Chris; Morley, Clare; Jefferies, Rosalyn; Gray, Richard

    2014-11-29

    Typically people who go to see their GP with a memory problem will be initially assessed and those patients who seem to be at risk will be referred onto a memory clinic. The demographic forces mean that memory services will need to expand to meet demand. An alternative may be to expand the role of primary care in dementia diagnosis and care. The aim of this study was to contrast patient, family member and professional experience of primary and secondary (usual) care led memory services. A qualitative, participatory study. A topic guide was developed by the peer and professional panels. Data were collected through peer led interviews of people with dementia, their family members and health professionals. Eleven (21%) of the 53 GP practices in Bristol offered primary care led dementia services. Three professional panels were held and were attended by 9 professionals; nine carers but no patients were involved in the three peer panels. These panels identified four main themes: GPs rarely make independent dementia diagnosis; GPs and memory nurses work together; patients and carers generally experience a high quality diagnostic service; an absence of post diagnostic support. Evidence relating to these themes was collected through a total of 46 participants took part; 23 (50%) in primary care and 23 (50%) in the memory service. Patients and carers were generally satisfied with either primary or secondary care led approaches to dementia diagnosis. Their major concern, shared with many health care professionals, was a lack of post diagnostic support.

  18. A portable time-domain LED fluorimeter for nanosecond fluorescence lifetime measurements

    NASA Astrophysics Data System (ADS)

    Wang, Hongtao; Qi, Ying; Mountziaris, T. J.; Salthouse, Christopher D.

    2014-05-01

    Fluorescence lifetime measurements are becoming increasingly important in chemical and biological research. Time-domain lifetime measurements offer fluorescence multiplexing and improved handling of interferers compared with the frequency-domain technique. In this paper, an all solid-state, filterless, and highly portable light-emitting-diode based time-domain fluorimeter (LED TDF) is reported for the measurement of nanosecond fluorescence lifetimes. LED based excitation provides more wavelengths options compared to laser diode based excitation, but the excitation is less effective due to the uncollimated beam, less optical power, and longer latency in state transition. Pulse triggering and pre-bias techniques were implemented in our LED TDF to improve the peak optical power to over 100 mW. The proposed pulsing circuit achieved an excitation light fall time of less than 2 ns. Electrical resetting technique realized a time-gated photo-detector to remove the interference of the excitation light with fluorescence. These techniques allow the LED fluorimeter to accurately measure the fluorescence lifetime of fluorescein down to concentration of 0.5 μM. In addition, all filters required in traditional instruments are eliminated for the non-attenuated excitation/emission light power. These achievements make the reported device attractive to biochemical laboratories seeking for highly portable lifetime detection devices for developing sensors based on fluorescence lifetime changes. The device was initially validated by measuring the lifetimes of three commercial fluorophores and comparing them with reported lifetime data. It was subsequently used to characterize a ZnSe quantum dot based DNA sensor.

  19. A portable time-domain LED fluorimeter for nanosecond fluorescence lifetime measurements

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hongtao; Salthouse, Christopher D., E-mail: salthouse@ecs.umass.edu; Center for Personalized Health Monitoring, University of Massachusetts, Amherst, Massachusetts 01003

    2014-05-15

    Fluorescence lifetime measurements are becoming increasingly important in chemical and biological research. Time-domain lifetime measurements offer fluorescence multiplexing and improved handling of interferers compared with the frequency-domain technique. In this paper, an all solid-state, filterless, and highly portable light-emitting-diode based time-domain fluorimeter (LED TDF) is reported for the measurement of nanosecond fluorescence lifetimes. LED based excitation provides more wavelengths options compared to laser diode based excitation, but the excitation is less effective due to the uncollimated beam, less optical power, and longer latency in state transition. Pulse triggering and pre-bias techniques were implemented in our LED TDF to improve themore » peak optical power to over 100 mW. The proposed pulsing circuit achieved an excitation light fall time of less than 2 ns. Electrical resetting technique realized a time-gated photo-detector to remove the interference of the excitation light with fluorescence. These techniques allow the LED fluorimeter to accurately measure the fluorescence lifetime of fluorescein down to concentration of 0.5 μM. In addition, all filters required in traditional instruments are eliminated for the non-attenuated excitation/emission light power. These achievements make the reported device attractive to biochemical laboratories seeking for highly portable lifetime detection devices for developing sensors based on fluorescence lifetime changes. The device was initially validated by measuring the lifetimes of three commercial fluorophores and comparing them with reported lifetime data. It was subsequently used to characterize a ZnSe quantum dot based DNA sensor.« less

  20. LED-driven backlights for automotive displays

    NASA Astrophysics Data System (ADS)

    Strauch, Frank

    2007-09-01

    As a light source the LED has some advantage over the traditionally used fluorescence tube such as longer life or lower space consumption. Consequently customers are asking for the LED lighting design in their products. We introduced in a company owned backlight the white LED technology. This step opens the possibility to have access to the components in the display market. Instead of having a finalized display product which needs to be integrated in the head unit of a car we assemble the backlight, the glass, own electronics and the housing. A major advantage of this concept is the better control of the heat flow generated by the LEDs to the outer side because only a common housing is used for all the components. Also the requirement for slim products can be fulfilled. As always a new technology doesn't come with advantages only. An LED represents a point source compared to the well-known tube thus requiring a mixing zone for the multiple point sources when they enter a light guide. This zone can't be used in displays because of the lack of homogeneity. It's a design goal to minimize this zone which can be helped by the right choice of the LED in terms of slimness. A step ahead is the implementation of RGB LEDs because of their higher color rendering abilities. This allows for the control of the chromaticity point under temperature change but as a drawback needs a larger mixing zone.

  1. Cryogenic characterization of LEDs for space application

    NASA Astrophysics Data System (ADS)

    Carron, Jérôme; Philippon, Anne; How, Lip Sun; Delbergue, Audrey; Hassanzadeh, Sahar; Cillierre, David; Danto, Pascale; Boutillier, Mathieu

    2017-09-01

    In the frame of EUCLID project, the Calibration Unit of the VIS (VISible Imager) instrument must provide an accurate and well characterized light source for in-flight instrument calibration without noise when it is switched off. The Calibration Unit consists of a set of LEDs emitting at various wavelengths in the visible towards an integrating sphere. The sphere's output provides a uniform illumination over the entire focal plane. Nine references of LEDs from different manufacturers were selected, screened and qualified under cryogenic conditions. Testing this large quantity of samples led to the implementation of automated testing equipment with complete in-situ monitoring of optoelectronic parameters as well as temperature and vacuum values. All the electrical and optical parameters of the LED have been monitored and recorded at ambient and cryogenic temperatures. These results have been compiled in order to show the total deviation of the LED electrical and electro-optical properties in the whole mission and to select the best suitable LED references for the mission. This qualification has demonstrated the robustness of COTS LEDs to operate at low cryogenic temperatures and in the space environment. Then 6 wavelengths were selected and submitted to an EMC sensitivity test at room and cold temperature by counting the number of photons when LEDs drivers are OFF. Characterizations were conducted in the full frequency spectrum in order to implement solutions at system level to suppress the emission of photons when the LED drivers are OFF. LEDs impedance was also characterized at room temperature and cold temperature.

  2. Thermal Analysis of LED Phosphor Layer

    NASA Astrophysics Data System (ADS)

    Perera, Ukwatte Lokuliyanage Indika Upendra

    Solid-state lighting technology has progressed to a level where light-emitting diode (LED) products are either on par or better than their traditional lighting technology counterparts with respect to efficacy and lifetime. At present, the most common method to create "white" light from LEDs for illumination applications is by using the LED primary radiation and wavelength-converting materials. In this method, the re-emission from the wavelength-converting materials excited by the LED primary radiation is combined with the LED primary radiation to create the "white" light. During this conversion process, heat is generated as a result of conversion inefficiencies and other loss mechanisms in the LED and the wavelength-converting materials. This generated heat, if not properly dissipated, increases the operating temperature, thereby increasing the light output degradation of the system over both the short and long term. The heat generation of the LED and thermal management of the LED have been studied extensively. Methods to effectively dissipate heat from the LEDs and maintain lower LED operating temperature are well understood. However, investigation of factors driving heat generation, the resulting temperature distribution in the phosphor layer, and the influence of the phosphor layer temperature on LED performance and reliability have not received the same focus. The goal of this dissertation was to understand the main factors driving heat and light generation and the transport of light and heat in the wavelength-converting layer of an LED system. Another goal was to understand the interaction between heat and light in the system and to develop and analyze a solution to reduce the wavelength-converting layer operating temperature, thereby improving light output and reliability. Even though past studies have explored generation and transfer separately for light and heat, to the best of the author's knowledge, this is the first study that has analyzed both factors

  3. Nurse-led treatment for occipital neuralgia.

    PubMed

    Pike, Denise; Amphlett, Alexander; Weatherby, Stuart

    Occipital neuralgia is a headache resulting from dysfunction of the occipital nerves. Medically resistant occipital neuralgia is treated by greater occipital nerve injection, which is traditionally performed by neurologists. A nurse-led clinic was developed to try to improve the service. Patient feedback showed that the clinic was positively perceived by patients, with most stating the nurse-led model was more efficient than the previous one, which had been led by consultants.

  4. Thermoresponsive scattering coating for smart white LEDs.

    PubMed

    Bauer, Jurica; Verbunt, Paul P C; Lin, Wan-Yu; Han, Yang; Van, My-Phung; Cornelissen, Hugo J; Yu, Joan J H; Bastiaansen, Cees W M; Broer, Dirk J

    2014-12-15

    White light emitting diode (LED) systems, capable of lowering the color temperature of emitted light on dimming, have been reported in the literature. These systems all use multiple color LEDs and complex control circuitry. Here we present a novel responsive lighting system based on a single white light emitting LED and a thermoresponsive scattering coating. The coated LED automatically emits light of lower correlated color temperature (CCT) when the power is reduced. We also present results on the use of multiple phosphors in the white light LED allowing for the emission of warm white light in the range between 2900 K and 4150 K, and with a chromaticity complying with the ANSI standards (C78.377). This responsive warm white light LED-system with close-to-ideal emission characteristics is highly interesting for the lighting industry.

  5. Kansas highway LED illumination manual : a guide for the use of LED lighting systems : [technical summary].

    DOT National Transportation Integrated Search

    2015-12-01

    The research project was aimed to assist the Kansas Department of Transportation (KDOT) in the development of a Highway LED Illumination Manual for guiding the upcoming implementation of successful LED roadway lighting systems in Kansas to replace th...

  6. Integration of organic LEDs with inorganic LEDs for a hybrid lighting system

    NASA Astrophysics Data System (ADS)

    Kong, H. J.; Park, J. W.; Kim, Y. M.

    2013-01-01

    We demonstrate that a surface-emitting hybrid light source can be realized by a combination of organic and inorganic light-emitting devices (LEDs). To this end, a blue inorganic LED bar is deployed at one side of a transparent light guide plate (LGP), and a yellow organic LED (OLED) is in contact with the rear surface of the LGP. In such a configuration, it is found that the overall luminance is almost equivalent to the sum of the luminances measured from each light source, and the overall luminance uniformity is determined mainly by the luminance uniformity of the OLED panel at high luminances. We have achieved a white color showing the Commission Internationale d'Eclairage (CIE) chromaticity coordinates of (x = 0.34, y = 0.33), the power efficiency of 9.3 lm/W, the luminance uniformity of 63% at the luminance of 3100 cd m-2, the color rendering index as high as 89.3, and the correlated color temperature finely tunable within the range between 3000 and 8000 K. Such a system facilitates color tuning by adjusting their luminous intensities and hence the implementation of the emotional lighting system.

  7. Significant growth in. LED use predicted.

    PubMed

    Simpson, Mike

    2012-03-01

    Although LED lighting has its critics, a number of whom (see article 'LED--panacea or marketing hype', HEJ--February 2012) are concerned about what they claim are some manufacturers' 'exaggerated claims' about lighting efficiency and lamp lifetime, Philips Lighting believes that, such are the advances being made in this innovative lighting technology, that LED's overall share of the European lighting market will have risen from around 7% in 2008 to 25% by 2020 and that, a decade later, it will account for a remarkable 75% of lighting sales. In the UK, Philips' technical and design director for Lighting, Mike Simpson, told HEJ editor, Jonathan Baillie, healthcare estates and facilities managers are increasingly recognising the potential to save energy, reduce carbon emissions, and cut maintenance costs, using LED.

  8. EC-LEDS Supports the Low-Carbon Transition

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    2016-09-01

    EC-LEDS is a flagship U.S. government-led effort that assists countries to create and implement low emission development strategies, or LEDS -- development frameworks that promote sustainable social and economic development while reducing greenhouse gas emissions over the medium to long term.

  9. Clinical Study: Change in Outlook Towards Birth After a Midwife Led Antenatal Education Programme Versus Hypnoreflexogenous Self-Hypnosis Training for Childbirth

    PubMed Central

    Streibert, L. A.; Reinhard, J.; Yuan, J.; Schiermeier, S.; Louwen, F.

    2015-01-01

    Aim: To compare the change of maternal outlook towards birth due to a midwife led antenatal education programme versus hypnoreflexogenous self-hypnosis training for childbirth. Method: Before beginning of the classes and after the last class maternal perception on birth was evaluated using Osgood semantic differential questionnaire. The Gießen personality score was evaluated once. Results: 213 patients were enrolled in this study. 155 were in the midwife led education programme and 58 in the self-hypnosis training programme. There was no statistically significant difference between the two groups in regard of participantsʼ characteristics, Gießen personality score and initial Osgood semantic differential scores. After the midwife led course childbirth was emotionally more negatively scored (displeasure, tarnishing, dimension evaluation [p < 0.05]), whereas after the hypnosis course childbirth was emotionally more positively evaluated (pleasure, harmony, dimension evaluation [p < 0.01] and brightness [p < 0.05]). Summary: In this study hypnoreflexogenous self-hypnosis training resulted in a positive maternal outlook towards childbirth, in comparison to the midwife led course. Further prospective randomised studies are required to test these initial results. PMID:26719600

  10. Remote monitoring of LED lighting system performance

    NASA Astrophysics Data System (ADS)

    Thotagamuwa, Dinusha R.; Perera, Indika U.; Narendran, Nadarajah

    2016-09-01

    The concept of connected lighting systems using LED lighting for the creation of intelligent buildings is becoming attractive to building owners and managers. In this application, the two most important parameters include power demand and the remaining useful life of the LED fixtures. The first enables energy-efficient buildings and the second helps building managers schedule maintenance services. The failure of an LED lighting system can be parametric (such as lumen depreciation) or catastrophic (such as complete cessation of light). Catastrophic failures in LED lighting systems can create serious consequences in safety critical and emergency applications. Therefore, both failure mechanisms must be considered and the shorter of the two must be used as the failure time. Furthermore, because of significant variation between the useful lives of similar products, it is difficult to accurately predict the life of LED systems. Real-time data gathering and analysis of key operating parameters of LED systems can enable the accurate estimation of the useful life of a lighting system. This paper demonstrates the use of a data-driven method (Euclidean distance) to monitor the performance of an LED lighting system and predict its time to failure.

  11. High-Modulation-Speed LEDs Based on III-Nitride

    NASA Astrophysics Data System (ADS)

    Chen, Hong

    III-nitride InGaN light-emitting diodes (LEDs) enable wide range of applications in solid-state lighting, full-color displays, and high-speed visible-light communication. Conventional InGaN quantum well LEDs grown on polar c-plane substrate suffer from quantum confined Stark effect due to the large internal polarization-related fields, leading to a reduced radiative recombination rate and device efficiency, which limits the performance of InGaN LEDs in high-speed communication applications. To circumvent these negative effects, non-trivial-cavity designs such as flip-chip LEDs, metallic grating coated LEDs are proposed. This oral defense will show the works on the high-modulation-speed LEDs from basic ideas to applications. Fundamental principles such as rate equations for LEDs/laser diodes (LDs), plasmonic effects, Purcell effects will be briefly introduced. For applications, the modal properties of flip-chip LEDs are solved by implementing finite difference method in order to study the modulation response. The emission properties of highly polarized InGaN LEDs coated by metallic gratings are also investigated by finite difference time domain method.

  12. White LED visible light communication technology research

    NASA Astrophysics Data System (ADS)

    Yang, Chao

    2017-03-01

    Visible light communication is a new type of wireless optical communication technology. White LED to the success of development, the LED lighting technology is facing a new revolution. Because the LED has high sensitivity, modulation, the advantages of good performance, large transmission power, can make it in light transmission light signal at the same time. Use white LED light-emitting characteristics, on the modulation signals to the visible light transmission, can constitute a LED visible light communication system. We built a small visible optical communication system. The system composition and structure has certain value in the field of practical application, and we also research the key technology of transmitters and receivers, the key problem has been resolved. By studying on the optical and LED the characteristics of a high speed modulation driving circuit and a high sensitive receiving circuit was designed. And information transmission through the single chip microcomputer test, a preliminary verification has realized the data transmission function.

  13. Evaluating UV-C LED disinfection performance and ...

    EPA Pesticide Factsheets

    This study evaluated ultraviolet (UV) light emitting diodes (LEDs) emitting at 260 nm, 280 nm, and the combination of 260|280 nm together for their efficacy at inactivating Escherichia. coli, MS2 coliphage, human adenovirus type 2 (HAdV2), and Bacillus pumilus spores; research included an evaluation of genomic damage. Inactivation by the LEDs was compared with the efficacy of conventional UV sources, the low-pressure (LP) and medium-pressure (MP) mercury vapor lamps. The work also calculated the electrical energy per order of reduction of the microorganisms by the five UV sources.For E. coli, all five UV sources yielded similar inactivation rates. For MS2 coliphage, the 260 nm LED was most effective. For HAdV2 and B. pumilus, the MP UV lamp was significantly more effective than the LP UV and UVC LED sources. When considering electrical energy per order of reduction, the LP UV lamp was the most efficient for E. coli and MS2, and the MPUV and LPUV were equally efficient for HAdV2 and B. pumilus spores. Among the UVC LEDs, the 280 nm LED unit required the least energy per log reduction of E. coli and HAdV2. The 280 nm and 260|280 nm LED units were equally efficient per log reduction of B. pumilus spores, and the 260 nm LED unit required the lowest energy per order of reduction of MS2 coliphage. The combination of the 260 nm and 280 nm UV LED wavelengths was also evaluated for potential synergistic effects. No dual-wavelength synergy was detected for inactivation of

  14. ZnO-nanorods: A possible white LED phosphor

    NASA Astrophysics Data System (ADS)

    Sarangi, Sachindra Nath; T., Arun; Ray, Dinseh K.; Sahoo, Pratap Kumar; Nozaki, Shinji; Sugiyama, Noriyuki; Uchida, Kazuo

    2017-05-01

    The white light-emitting diodes (LEDs) have drawn much attention to replace conventional lighting sources because of low energy consumption, high light efficiency and long lifetime. Although the most common approach to produce white light is to combine a blue LED chip and a yellow phosphor, such a white LED cannot be used for a general lighting application, which requires a broad luminescence spectrum in the visible wavelength range. We have successfully chemically synthesized the ZnO nanorods showing intense broad luminescence in the visible wavelength range and made a white LED using the ZnO nanorods as phosphor excited with a blue LED. Their lengths and diameters were 2 - 10 μm and 200 - 800 nm, respectively. The wurtzite structure was confirmed by the x-ray diffraction measurement. The PL spectrum obtained by exciting the ZnO nanorods with the He-Cd laser has two peaks, one associated with the near band-edge recombination and the other with recombination via defects. The peak intensity of the near band-edge luminescence at 388 nm is much weaker than that of the defect-related luminescence. The latter luminescence peak ranges from 450 to 850 nm and broad enough to be used as a phosphor for a white LED. A white LED has been fabricated using a blue LED with 450 nm emission and ZnO nanorod powders. The LED performances show a white light emission and the electroluminescence measurement shows a stiff increase in white light intensity with increasing blue LED current. The Commission International de1'Eclairage (CIE) chromaticity colour coordinates of 450 nm LED pumped white emission shows a coordinate of (0.31, 0.32) for white LED at 350 mA. These results indicate that ZnO nanorods provides an alternate and effective approach to achieve high-performance white LEDs and also other optoelectronic devices.

  15. Accessible Transportation Technologies Research Initiative (ATTRI) : User Needs Assessment: Stakeholder Engagement Report.

    DOT National Transportation Integrated Search

    2016-05-01

    The Accessible Transportation Technologies Research Initiative (ATTRI) is a joint U.S. Department of Transportation (U.S. DOT) initiative that is co-led by the Federal Highway Administration (FHWA) and the Federal Transit Administration (FTA). ATTRI ...

  16. Community-Led Initiatives in Curriculum Development.

    ERIC Educational Resources Information Center

    Sherman, Kerry

    Educational curricula have often been shaped more by worldwide standards and modern values than by national or regional influences and may, in some cases, be irrelevant to student and local community needs. This paper explores ways in which curricula can be adapted to a region's specific, social, political, and regional conditions. It begins with…

  17. Thermal management of LEDs: package to system

    NASA Astrophysics Data System (ADS)

    Arik, Mehmet; Becker, Charles A.; Weaver, Stanton E.; Petroski, James

    2004-01-01

    Light emitting diodes, LEDs, historically have been used for indicators and produced low amounts of heat. The introduction of high brightness LEDs with white light and monochromatic colors have led to a movement towards general illumination. The increased electrical currents used to drive the LEDs have focused more attention on the thermal paths in the developments of LED power packaging. The luminous efficiency of LEDs is soon expected to reach over 80 lumens/W, this is approximately 6 times the efficiency of a conventional incandescent tungsten bulb. Thermal management for the solid-state lighting applications is a key design parameter for both package and system level. Package and system level thermal management is discussed in separate sections. Effect of chip packages on junction to board thermal resistance was compared for both SiC and Sapphire chips. The higher thermal conductivity of the SiC chip provided about 2 times better thermal performance than the latter, while the under-filled Sapphire chip package can only catch the SiC chip performance. Later, system level thermal management was studied based on established numerical models for a conceptual solid-state lighting system. A conceptual LED illumination system was chosen and CFD models were created to determine the availability and limitations of passive air-cooling.

  18. Patient-led versus physician-led titration of insulin glargine in patients with uncontrolled type 2 diabetes: a randomized multinational ATLAS study.

    PubMed

    Garg, Satish K; Admane, Karim; Freemantle, Nick; Odawara, Masato; Pan, Chang-Yu; Misra, Anoop; Jarek-Martynowa, Iwona R; Abbas-Raza, Syed; Mirasol, Roberto C; Perfetti, Riccardo

    2015-02-01

    Self-adjustment of insulin dose is commonly practiced in Western patients with type 2 diabetes but is usually not performed in Asian patients. This multinational, 24-week, randomized study compared patient-led with physician-led titration of once-daily insulin glargine in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering agents. Patient-led (n = 275) or physician-led (n = 277) subjects followed the same dose-titration algorithm guided by self-monitored fasting blood glucose (FBG; target, 110 mg/dL [6.1 mmol/L]). The primary endpoint was change in mean glycated hemoglobin (HbA1c) at week 24 in the patient-led versus physician-led titration groups. Patient-led titration resulted in a significantly higher drop in HbA1c value at 24 weeks when compared with physician-led titration (-1.40% vs. -1.25%; mean difference, -0.15; 95% confidence interval, -0.29 to 0.00; P = .043). Mean decrease in FBG was greatest in the patient-led group (-2.85 mmol/L vs. -2.48 mmol/L; P = .001). The improvements in HbA1c and FBG were consistent across countries, with similar improvements in treatment satisfaction in both groups. Mean daily insulin dose was higher in the patient-led group (28.9 units vs. 22.2 units; P<.001). Target HbA1c of <7.0% without severe hypoglycemia was achieved in 40.0% and 32.9% in the patient-led and physician-led groups, respectively (P = .086). Severe hypoglycemia was not different in the 2 groups (0.7%), with an increase in nocturnal and symptomatic hypoglycemia in the patient-led arm. Patient-led insulin glargine titration achieved near-target blood glucose levels in Asian patients with uncontrolled type 2 diabetes who were on 2 oral glucose-lowering drugs, demonstrating that Asian patients can self-uptitrate insulin dose effectively when guided.

  19. Service-Learning Initiatives in Nursing Education

    ERIC Educational Resources Information Center

    O'Shea, Eileen; Planas, Jessica; Quan, Melissa; Greiner, Lydia; Kazer, Meredith; Babington, Lynn

    2013-01-01

    In response to the changing demands of the U.S. healthcare system and the needs of the nursing profession, the Institute of Medicine, in collaboration with the Robert Wood Johnson Foundation, spearheaded a two-year initiative to develop recommendations for the future of nursing. Discussions of these recommendations within nursing education led to…

  20. Talking with text: communication in therapist-led, live chat cancer support groups.

    PubMed

    Stephen, Joanne; Collie, Kate; McLeod, Deborah; Rojubally, Adina; Fergus, Karen; Speca, Michael; Turner, Jill; Taylor-Brown, Jill; Sellick, Scott; Burrus, Kimberly; Elramly, Mai

    2014-03-01

    CancerChatCanada is a pan-Canadian initiative with a mandate to make professionally led cancer support groups available to more people in Canada. Although online support groups are becoming increasingly popular, little is known about therapist-led, synchronous groups using live chat. The purpose of this study was to generate a rich descriptive account of communication experiences in CancerChatCanada groups and to gain an understanding of processes associated with previously-reported benefits. We used interpretive description to analyze interview segments from 102 patients, survivors and family caregivers who participated in CancerChatCanada groups between 2007 and 2011. The analysis yielded four inter-related process themes (Reaching Out From Home, Feeling Safe, Emotional Release, and Talking With Text) and one outcome theme (Resonance and Kinship). The findings extend previous research about text-only online support groups and provide novel insights into features of facilitated, live chat communication that are valued by group members. Copyright © 2013 Elsevier Ltd. All rights reserved.

  1. Urgent care centre redirection: evaluation of a nurse-led intervention.

    PubMed

    Groom, Nicola; Kidd, Tara; Carey, Nicola

    2018-02-09

    Patient redirection can help reduce service demand by providing information about more appropriate services. There is, however, no evidence about the effect of nurse-led patient redirection in urgent care centre settings. The aim of this project was to develop and evaluate a nurse-led patient 'self-care and redirection first' intervention in an urgent care centre (UCC). Adopting a prospective observational design, the intervention was delivered to an opportunity sample of patients who attended a south London hospital UCC, between June and July 2014, and evaluated through patient interviews five to ten days after initial attendance. 118 of the 1,710 people who attended the UCC participated in the intervention, of whom 81 (69%) were redirected to other services or home to self-care, and 37 were transferred to an emergency department. Of the 110 (93.2%) participants who completed the questionnaire, 97.2% were satisfied with the service. Only two accessed different services to those recommended, 72.2% ( n =85) said they would not reattend a UCC for a similar condition. Treating minor ailments in a UCC is an inefficient use of resources. A nurse-led self-care and redirection intervention can help divert patients with minor ailments to more appropriate services. Further evaluation of the effect of the intervention on service demand and costs is required. ©2018 RCN Publishing Company Ltd. All rights reserved. Not to be copied, transmitted or recorded in any way, in whole or part, without prior permission of the publishers.

  2. Medical Applications of White LEDs for Surgical Operation

    NASA Astrophysics Data System (ADS)

    Shimada, Junichi; Kawakami, Yoichi

    Everywhere in the world, the highest quality and quantity of lighting is required during the surgical operations. However, the surgical approach has had many types and various angles, common ceiling surgical halogen lighting system cannot provide an adequate amount of beams because the surgeons' heads hinder the illuminations from reaching the operation field. The evolution of solid-state-lighting is currently going to be developed due to the progress of white light emitting diodes (LEDs). We proposed and developed the new lighting equipment that is a surgical lighting goggle composed of InGaN-YAG (yttrium aluminum garnet):Ce3+-based white LEDs. Here, we newly design surgical lighting system composed of white LEDs equipped on both sides of goggles. In fact, we have succeeded in the first internal shunt operation in the left forearm using the surgical LED lighting system on 11th Sept 2000. Since the white LEDs used were composed of InGaN-blue-emitters and YAG-yellow-phosphors, the color rendering property was not sufficient in the reddish colors. After our first challenge for medical application of white LEDs, we have been trying to improve the luminance power of white LED, the color rendering in red colors and the spectral distribution of white LED to render inherent color of raw flesh such as skin, blood, fat tissue and internal organs. We have produced new concepts for LED lighting sources and new several generations of LED lighting goggles.

  3. Multiple LEDs luminous system in capsule endoscope

    NASA Astrophysics Data System (ADS)

    Mang, Ou-Yang; Huang, Shih-Wei; Lee, Hsin-Hung; Chen, Yung-Lin; Huang, Ko-Chih; Kuo, Yi-Ting

    2007-02-01

    Developing the luminous system in a capsule endoscope, it is difficult to obtain an uniform illumination[1] on the observed object because of several reasons: the light pattern of LED is sensitively depend on the driving current, location and projective angles; the optical path of LED light source is not parallel to the optical axis of the nearby imaging lenses; the strong reflection from the inner surface of the dome may saturate the CMOS sensors; the object plane of the observed intestine is not flat. Those reasons induce the over-blooming and deep-dark contrast in a picture and distort the original image strongly. The purpose of the article is to construct a photometric model to analyze the LED projection light pattern, and, furthermore, design a novel multiple LEDs luminous system for obtaining an uniform-brightness image. Several key parameters resulting as illumination uniformity has been taken under the model consideration and proven by experimental results. Those parameters include LED light pattern accuracy, choosing LED position relative to the imaging optical axis, LED numbers, arrangement, and the inner curvature of the dome. The novel structure improves the uniformity from 41% to 71% and reduces the light energy loss under 2%. The progress will help medical professionals to diagnose diseases and give treatment precisely based on the vivid image.

  4. Interventions for promoting the initiation of breastfeeding.

    PubMed

    Balogun, Olukunmi O; O'Sullivan, Elizabeth J; McFadden, Alison; Ota, Erika; Gavine, Anna; Garner, Christine D; Renfrew, Mary J; MacGillivray, Stephen

    2016-11-09

    potential sources (N = 17). Healthcare professional-led breastfeeding education and support versus standard care The studies pooled here compare professional health workers delivering breastfeeding education and support during the prenatal and postpartum periods with standard care. Interventions included promotion campaigns and counselling, and all took place in a formal setting. There was evidence from five trials involving 564 women for improved rates ofbreastfeeding initiation among women who received healthcare professional-led breastfeeding education and support (average risk ratio (RR) 1.43, 95% confidence interval (CI) 1.07 to 1.92; Tau² = 0.07, I² = 62%, low-quality evidence) compared to those women who received standard care. We downgraded evidence due to design limitations and heterogeneity. The outcome of early initiation of breastfeeding was not reported in the studies under this comparison. Non-healthcare professional-led breastfeeding education and support versus standard care There was evidence from eight trials of 5712 women for improved rates of breastfeeding initiation among women who received interventions from non-healthcare professional counsellors and support groups (average RR 1.22, 95% CI 1.06 to 1.40; Tau² = 0.02, I² = 86%, low-quality evidence) compared to women who received standard care. In three trials of 76,373 women, there was no clear difference between groups in terms of the number of women practicing early initiation of breastfeeding (average RR 1.70, 95% CI 0.98 to 2.95; Tau² = 0.18, I² = 78%, very low-quality evidence). We downgraded the evidence for a combination of design limitations, heterogeneity and imprecision (wide confidence intervals crossing the line of no effect). Other comparisonsOther comparisons in this review also looked at the rates of initiation of breastfeeding and there were no clear differences between groups for the following comparisons of combined healthcare professional-led education with peer support or

  5. Evaluating the outcomes of a podiatry-led assessment service in a public hospital orthopaedic unit.

    PubMed

    Bonanno, Daniel R; Medica, Virginia G; Tan, Daphne S; Spring, Anita A; Bird, Adam R; Gazarek, Jana

    2014-01-01

    In Australia, the demand for foot and ankle orthopaedic services in public health settings currently outweighs capacity. Introducing experienced allied health professionals into orthopaedic units to initiate the triage, assessment and management of patients has been proposed to help meet demand. The aim of this study was to evaluate the effect of introducing a podiatry-led assessment service in a public hospital orthopaedic unit. The outcomes of interest were determining: the proportion of patients discharged without requiring an orthopaedic appointment, agreement in diagnosis between the patient referral and the assessing podiatrist, the proportion of foot and ankle conditions presenting to the service, and the proportion of each condition to require an orthopaedic appointment. This study audited the first 100 patients to receive an appointment at a new podiatry-led assessment service. The podiatrist triaged 'Category 3' referrals consisting of musculoskeletal foot and ankle conditions and appointments were provided for those considered likely to benefit from non-surgical management. Following assessment, patients were referred to an appropriate healthcare professional or were discharged. At the initial appointment or following a period of care, patients were discharged if non-surgical management was successful, surgery was not indicated, patients did not want surgery, and if patient's failed to attend their appointments. All other patients were referred for an orthopaedic consultation as indicated. Ninety-five of the 100 patients (69 females and 31 males; mean age 51.9, SD 16.4 years) attended their appointment at the podiatry-led assessment service. The 95 referrals contained a total of 107 diagnoses, of which the podiatrist agreed with the diagnosis stated on the referral in 56 cases (Kappa =0.49, SE = 0.05). Overall, 34 of the 100 patients were referred to an orthopaedic surgeon and the remaining 66 patients were discharged from the orthopaedic waiting

  6. The activities of a dietitian-led gastroenterology clinic using extended scope of practice.

    PubMed

    Ryan, Dominique; Pelly, Fiona; Purcell, Elizabeth

    2016-10-21

    Extending the scope of practice of allied health professionals has been a strategy adopted in the United Kingdom to address issues within the health system. Australia's health system is currently undermined by similar issues, heightening government interest in adopting the extended scope health care model. The aim of the current study was to describe the activities and outcomes of a dietitian-led gastroenterology clinic which operated under an extended scope of practice model in an outpatient gastroenterology department at a tertiary hospital in regional Queensland, Australia, and to assess patient satisfaction with the initiative. A descriptive, cross-sectional case series undertaken over 50 clinics involving 82 category 2 and 3 patients with suspected/confirmed coeliac disease or inflammatory bowel disease; low haemoglobin; gastroesophageal reflux disease, or; malnutrition. Data was analysed using Microsoft Excel 2010, and presented as descriptive statistics. Sixty out of 82 selected patients (median age 51 years) attended an initial appointment with the dietitian. Twenty-four review appointments were attended. Average waiting period for an initial appointment was 148 days (range 31-308 days). A total of 149 management strategies were provided, and 94 (63 %) of these involved the dietitian utilising extended scope of practice. The dietitian managed 47 (78 %) patients without need for gastroenterologist referral, and 25 (42 %) were discharged after dietetic management. Patients reported high levels of satisfaction with the clinic. Seventy-eight percent of category 2 and 3 patients referred to the gastroenterologist could be managed exclusively in the dietitian-led clinic. This extended scope model of care could potentially benefit the efficiency and acceptability of Australia's public health system.

  7. LED-pumped Alexandrite laser oscillator and amplifier

    NASA Astrophysics Data System (ADS)

    Pichon, Pierre; Blanchot, Jean-Philippe; Balembois, François; Druon, Frédéric; Georges, Patrick

    2018-02-01

    In this paper, we report the first LED-pumped transition-metal-doped laser oscillator and amplifier based on an alexandrite crystal (Cr3+:BeAl2O4). A Ce:YAG luminescent concentrator illuminated by blue LEDs is used to reach higher pump powers than with LEDs alone. The luminescent 200-mm-long-composit luminescent concentrator involving 2240 LEDs can delivers up to 268 mJ for a peak irradiance of 8.5 kW/cm2. In oscillator configuration, an LED-pumped alexandrite laser delivering an energy of 2.9 mJ at 748 nm in free running operation is demonstrated. In the cavity, we measured a double pass small signal gain of 1.28, in good agreement with numerical simulations. As amplifier, the system demonstrated to boost a CW Ti:sapphire laser by a factor of 4 at 750 nm in 8 passes with a large tuning range from 710 nm to 800 nm.

  8. Open LED Illuminator: A Simple and Inexpensive LED Illuminator for Fast Multicolor Particle Tracking in Neurons

    PubMed Central

    Bosse, Jens B.; Tanneti, Nikhila S.; Hogue, Ian B.; Enquist, Lynn W.

    2015-01-01

    Dual-color live cell fluorescence microscopy of fast intracellular trafficking processes, such as axonal transport, requires rapid switching of illumination channels. Typical broad-spectrum sources necessitate the use of mechanical filter switching, which introduces delays between acquisition of different fluorescence channels, impeding the interpretation and quantification of highly dynamic processes. Light Emitting Diodes (LEDs), however, allow modulation of excitation light in microseconds. Here we provide a step-by-step protocol to enable any scientist to build a research-grade LED illuminator for live cell microscopy, even without prior experience with electronics or optics. We quantify and compare components, discuss our design considerations, and demonstrate the performance of our LED illuminator by imaging axonal transport of herpes virus particles with high temporal resolution. PMID:26600461

  9. New reversing design method for LED uniform illumination.

    PubMed

    Wang, Kai; Wu, Dan; Qin, Zong; Chen, Fei; Luo, Xiaobing; Liu, Sheng

    2011-07-04

    In light-emitting diode (LED) applications, it is becoming a big issue that how to optimize light intensity distribution curve (LIDC) and design corresponding optical component to achieve uniform illumination when distance-height ratio (DHR) is given. A new reversing design method is proposed to solve this problem, including design and optimization of LIDC to achieve high uniform illumination and a new algorithm of freeform lens to generate the required LIDC by LED light source. According to this method, two new LED modules integrated with freeform lenses are successfully designed for slim direct-lit LED backlighting with thickness of 10mm, and uniformities of illuminance increase from 0.446 to 0.915 and from 0.155 to 0.887 when DHRs are 2 and 3 respectively. Moreover, the number of new LED modules dramatically decreases to 1/9 of the traditional LED modules while achieving similar uniform illumination in backlighting. Therefore, this new method provides a practical and simple way for optical design of LED uniform illumination when DHR is much larger than 1.

  10. An overview of LED applications for general illumination

    NASA Astrophysics Data System (ADS)

    Pelka, David G.; Patel, Kavita

    2003-11-01

    This paper begins by reviewing the current state of development of LEDs, their existing markets as well as their potential for energy conservation and their potential for gaining market share in the general illumination market. It discusses LED metrics such as chip size, lumens per watt, thermal resistance, and the recommended maximum current rating. The paper then goes on to consider the importance of non-imaging optics for both optically efficient and extremely compact LED lighting systems. Finally, microstructures useful for controlling the fields-of-view of LED lighting systems are considered and described in some detail. An extremely efficient and cost effective microstructure, called kinoform diffusers, is shown to have very unique properties that make this technology almost ideal for shaping the output beams of LED lighting systems. It concludes by illustrating some general illumination LED lighting systems

  11. Thermophotonics for ultra-high efficiency visible LEDs

    NASA Astrophysics Data System (ADS)

    Ram, Rajeev J.

    2017-02-01

    The wall-plug efficiency of modern light-emitting diodes (LEDs) has far surpassed all other forms of lighting and is expected to improve further as the lifetime cost of a luminaire is today dominated by the cost of energy. The drive towards higher efficiency inevitably opens the question about the limits of future enhancement. Here, we investigate thermoelectric pumping as a means for improving efficiency in wide-bandgap GaN based LEDs. A forward biased diode can work as a heat pump, which pumps lattice heat into the electrons injected into the active region via the Peltier effect. We experimentally demonstrate a thermally enhanced 450 nm GaN LED, in which nearly fourfold light output power is achieved at 615 K (compared to 295 K room temperature operation), with virtually no reduction in the wall-plug efficiency at bias V < ℏω/q. This result suggests the possibility of removing bulky heat sinks in high power LED products. A review of recent high-efficiency GaN LEDs suggests that Peltier thermal pumping plays a more important role in a wide range of modern LED structures that previously thought - opening a path to even higher efficiencies and lower lifetime costs for future lighting.

  12. Investigation of Passive Filter for LED Lamp

    NASA Astrophysics Data System (ADS)

    Sarwono, Edi; Facta, Mochammad; Handoko, Susatyo

    2017-04-01

    Light Emitting Diode lamp or LED lamp is one of the energy saving lamps nowadays widely used by consumers. However, LED lamp has contained harmonics caused by the rectifier circuit inside the lamp. Harmonics cause a quality problem in power system. As the harmonics present in current or voltage, the waveforms are distorted. Harmonics can lead to overheating in magnetic core of electrical equipments. In this paper, several tests are carried out to investigate the harmonic content of voltage and currents, and also the level of light intensity of the two brands of LED lamps. Measurements in this study are conducted by using HIOKI Power Quality Analyzer 3197. The test results show that the total harmonic distortion or THD of voltage on various brands of LED lamps did not exceed 5% as in compliance to the limit of IEEE standard 519-1992. The largest harmonic voltage is 2.9%, while maximum harmonic current for tested brands of LED lamp is 170.6%. The use of low pass filter in the form of LC filter was proposed. Based on experimental results, the application of LC filter at input side of LED lamp has successfully reduced THD current in the range of 85%-88%.

  13. High-aggregate-capacity visible light communication links using stacked multimode polymer waveguides and micro-pixelated LED arrays

    NASA Astrophysics Data System (ADS)

    Bamiedakis, N.; McKendry, J. J. D.; Xie, E.; Gu, E.; Dawson, M. D.; Penty, R. V.; White, I. H.

    2018-02-01

    In recent years, light emitting diodes (LEDs) have gained renewed interest for use in visible light communication links (VLC) owing to their potential use as both high-quality power-efficient illumination sources as well as low-cost optical transmitters in free-space and guided-wave links. Applications that can benefit from their use include optical wireless systems (LiFi and Internet of Things), in-home and automotive networks, optical USBs and short-reach low-cost optical interconnects. However, VLC links suffer from the limited LED bandwidth (typically 100 MHz). As a result, a combination of novel LED devices, advanced modulation formats and multiplexing methods are employed to overcome this limitation and achieve high-speed (>1 Gb/s) data transmission over such links. In this work, we present recent advances in the formation of high-aggregate-capacity low cost guided wave VLC links using stacked polymer multimode waveguides and matching micro-pixelated LEDLED) arrays. μLEDs have been shown to exhibit larger bandwidths (>200 MHz) than conventional broad-area LEDs and can be formed in large array configurations, while multimode polymer waveguides enable the formation of low-cost optical links onto standard PCBs. Here, three- and four-layered stacks of multimode waveguides, as well as matching GaN μLED arrays, are fabricated in order to generate high-density yet low-cost optical interconnects. Different waveguide topologies are implemented and are investigated in terms of loss and crosstalk performance. The initial results presented herein demonstrate good intrinsic crosstalk performance and indicate the potential to achieve >= 0.5 Tb/s/mm2 aggregate interconnection capacity using this low-cost technology.

  14. High-power LEDs for plant cultivation

    NASA Astrophysics Data System (ADS)

    Tamulaitis, Gintautas; Duchovskis, Pavelas; Bliznikas, Zenius; Breive, Kestutis; Ulinskaite, Raimonda; Brazaityte, Ausra; Novickovas, Algirdas; Zukauskas, Arturas; Shur, Michael S.

    2004-10-01

    We report on high-power solid-state lighting facility for cultivation of greenhouse vegetables and on the results of the study of control of photosynthetic activity and growth morphology of radish and lettuce imposed by variation of the spectral composition of illumination. Experimental lighting modules (useful area of 0.22 m2) were designed based on 4 types of high-power light-emitting diodes (LEDs) with emission peaked in red at the wavelengths of 660 nm and 640 nm (predominantly absorbed by chlorophyll a and b for photosynthesis, respectively), in blue at 455 nm (phototropic function), and in far-red at 735 nm (important for photomorphology). Morphological characteristics, chlorophyll and phytohormone concentrations in radish and lettuce grown in phytotron chambers under lighting with different spectral composition of the LED-based illuminator and under illumination by high pressure sodium lamps with an equivalent photosynthetic photon flux density were compared. A well-balanced solid-state lighting was found to enhance production of green mass and to ensure healthy morphogenesis of plants compared to those grown using conventional lighting. We observed that the plant morphology and concentrations of morphologically active phytohormones is strongly affected by the spectral composition of light in the red region. Commercial application of the LED-based illumination for large-scale plant cultivation is discussed. This technology is favorable from the point of view of energy consumption, controllable growth, and food safety but is hindered by high cost of the LEDs. Large scale manufacturing of high-power red AlInGaP-based LEDs emitting at 650 nm and a further decrease of the photon price for the LEDs emitting in the vicinity of the absorption peak of chlorophylls have to be achieved to promote horticulture applications.

  15. LED structure with enhanced mirror reflectivity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bergmann, Michael; Donofrio, Matthew; Heikman, Sten

    2014-04-01

    Embodiments of the present invention are generally related to LED chips having improved overall emission by reducing the light-absorbing effects of barrier layers adjacent mirror contacts. In one embodiment, a LED chip comprises one or more LEDs, with each LED having an active region, a first contact under the active region having a highly reflective mirror, and a barrier layer adjacent the mirror. The barrier layer is smaller than the mirror such that it does not extend beyond the periphery of the mirror. In another possible embodiment, an insulator is further provided, with the insulator adjacent the barrier layer andmore » adjacent portions of the mirror not contacted by the active region or by the barrier layer. In yet another embodiment, a second contact is provided on the active region. In a further embodiment, the barrier layer is smaller than the mirror such that the periphery of the mirror is at least 40% free of the barrier layer, and the second contact is below the first contact and accessible from the bottom of the chip.« less

  16. Designing low cost LED display for the billboard

    NASA Astrophysics Data System (ADS)

    Hong, Yi-Jian; Uang, Chii-Maw; Wang, Ping-Chieh; Ho, Zu-Sheng

    2011-10-01

    With quickly advance of the computer, microelectronics and photonics technologies, LED display panel becomes a new electronic advertising media. It can be used to show any information whatever characters or graphics. Most LED display panels are built of many Light-Emitting Diodes arranged in a matrix form. The display has many advantages such as low power, low cost, long life and high definition. Because the display panel is asked to show rich color, the LED display panel's driving system becomes very complex. The design methodology of LED display panel's driver becomes more and more important to meet the market requirements. Cost is always the most important issue in public market domain. In this paper, we report a design methodology of LED display panel's driver based on the microprocessor control unit (MCU) system and LED display controller IC, HT1632C, to control three colors, RGB, color LED display panel and the modular panel size is 24*16 in matrix form. The HT1632C is a memory mapping LED display controller, it can be used on many applications, such as digital clock, thermometer, counter, voltmeter or other instrumentation readouts. Three pieces of HT1632C are used to drive a 24*16 RGB LED display panel, in our design case. Each HT163C chip is used to control one of the R, G and B color. As the drive mode is driven in DC mode, the RGB display panel can create and totally of seven colors under the control of MCU. The MCU generates the control signal to drive HT1632C. In this study, the software design methodology is adopted with dynamic display principle. When the scan frequency is 60Hz, LED display panel will get the clear picture and be able to display seven colors.

  17. Parent, Student, and Teacher Perceptions of Student-Led Conferences and Strategies to Host Effective Student-Led Conferences

    ERIC Educational Resources Information Center

    Jackson, Sharon M.

    2012-01-01

    This is a mixed-methods case study designed to examine the perceptions parents, students and teachers have about student-led conferences with the purpose of informing practices at the researcher's school as well as sharing strategies used to host effective student-led conferences. Parents and students were interviewed and surveyed. Teachers were…

  18. Modular design of the LED vehicle projector headlamp system.

    PubMed

    Hsieh, Chi-Chang; Li, Yan-Huei; Hung, Chih-Ching

    2013-07-20

    A well designed headlamp for a vehicle lighting system is very important as it provides drivers with safe and comfortable driving conditions at night or in dark places. With the advances of the semiconductor technology, the LED has become the fourth generation lighting source in the auto industry. In this study, we will propose a LED vehicle projector headlamp system. This headlamp system contains several LED headlamp modules, and every module of it includes four components: focused LEDs, asymmetric metal-based plates, freeform surfaces, and condenser lenses. By optimizing the number of LED headlamp modules, the proposed LED vehicle projector headlamp system has only five LED headlamp modules. It not only provides the low-beam cutoff without a shield, but also meets the requirements of the ECE R112 regulation. Finally, a prototype of the LED vehicle projector headlamp system was assembled and fabricated to create the correct light pattern.

  19. LEDs based upon AlGaInP heterostructures with multiple quantum wells: comparison of fast neutrons and gamma-quanta irradiation

    NASA Astrophysics Data System (ADS)

    Gradoboev, A. V.; Orlova, K. N.; Simonova, A. V.

    2018-05-01

    The paper presents the research results of watt and volt characteristics of LEDs based upon AlGaInP heterostructures with multiple quantum wells in the active region. The research is completed for LEDs (emission wavelengths 624 nm and 590 nm) under irradiation by fast neutron and gamma-quanta in passive powering mode. Watt-voltage characteristics in the average and high electron injection areas are described as a power function of the operating voltage. It has been revealed that the LEDs transition from average electron injection area to high electron injection area occurs by overcoming the transition area. It disappears as it get closer to the limit result of the irradiation LEDs that is low electron injection mode in the entire supply voltage range. It has been established that the gamma radiation facilitates initial defects restructuring only 42% compared to 100% when irradiation is performed by fast neutrons. Ratio between measured on the boundary between low and average electron injection areas current value and the contribution magnitude of the first stage LEDs emissive power reducing is established. It is allows to predict LEDs resistance to irradiation by fast neutrons and gamma rays.

  20. Promoting Active Citizenship through the Arts and Youth: Canadian Youth-Led Organizations as Beacons of Hope and Transformation

    ERIC Educational Resources Information Center

    Porfilio, Brad J.; Gorlewski, Julie A.

    2012-01-01

    This essay details the pedagogical and cultural work of two youth-led organizations situated in Canada--Beat Nation and 411 Initiative for Change. Through the narratives generated by interviews with several of the organizations' artists and founders, the organizations' pedagogical work generated in cyberspace, and through artists' music,…

  1. LED roadway luminaires evaluation.

    DOT National Transportation Integrated Search

    2012-02-01

    This research explores whether LED roadway luminaire technologies are a viable future solution to providing roadway lighting. Roadway lighting : enhances highway safety and traffic flow during limited lighting conditions. The purpose of this evaluati...

  2. Case study: technology initiative led to advanced lead optimization screening processes at Bristol-Myers Squibb, 2004-2009.

    PubMed

    Zhang, Litao; Cvijic, Mary Ellen; Lippy, Jonathan; Myslik, James; Brenner, Stephen L; Binnie, Alastair; Houston, John G

    2012-07-01

    In this paper, we review the key solutions that enabled evolution of the lead optimization screening support process at Bristol-Myers Squibb (BMS) between 2004 and 2009. During this time, technology infrastructure investment and scientific expertise integration laid the foundations to build and tailor lead optimization screening support models across all therapeutic groups at BMS. Together, harnessing advanced screening technology platforms and expanding panel screening strategy led to a paradigm shift at BMS in supporting lead optimization screening capability. Parallel SAR and structure liability relationship (SLR) screening approaches were first and broadly introduced to empower more-rapid and -informed decisions about chemical synthesis strategy and to broaden options for identifying high-quality drug candidates during lead optimization. Copyright © 2012 Elsevier Ltd. All rights reserved.

  3. Innovations in LED lighting for reduced-ESM crop production in space

    NASA Astrophysics Data System (ADS)

    Massa, Gioia; Mitchell, Cary; Bourget, C. Michael; Morrow, Robert

    In controlled-environment crop production such as will be practiced at the lunar outpost and Mars base, the single most energy-demanding aspect is electric lighting for plant growth, including energy costs for energizing lamps as well as for removing excess heat. For a variety of reasons, sunlight may not be a viable option as the main source of crop lighting off-Earth and traditional electric lamps for crop lighting have numerous drawbacks for use in a space environment. A collaborative research venture between the Advanced Life Support Crops Group at Purdue University and the Orbital Technologies Corporation (ORBITEC) has led to the development of efficient, reconfigurable LED lighting technologies for crop growth in an ALSS. The light sources use printed-circuit red and blue LEDs, which are individually tunable for a range of photosynthetic photon fluxes and photomorphogenic plant responses. Initial lighting arrays have LEDs that can be energized from the bottom upward when deployed in a vertical, intracanopy configuration, allowing the illumination to be tailored for stand height throughout the cropping cycle. Preliminary testing with the planophile crop cowpea (Vigna unguiculata L. Walp, breeding line IT87D-941-1), resulted in optimizing internal reflectance of growth compartments by lining walls, floor, and a movable ceiling with white Poly film, as well as by determining optimal planting density and plant positioning. Additionally, these light strips, called "lightsicles", can be configured into an overhead plane of light engines. When intracanopy and overhead-LED-lit cowpea crop production was compared, cowpea plants grown with intracanopy lighting had much greater understory leaf retention and produced more dry biomass per kilowatt-hour of lighting energy than did overhead-lit plants. The efficiency of light capture is reduced in overhead-lit scenarios due to mutual shading of lower leaves by upper leaves in closed canopies leading to premature abscission

  4. Conduction-driven cooling of LED-based automotive LED lighting systems for abating local hot spots

    NASA Astrophysics Data System (ADS)

    Saati, Ferina; Arik, Mehmet

    2018-02-01

    Light-emitting diode (LED)-based automotive lighting systems pose unique challenges, such as dual-side packaging (front side for LEDs and back side for driver electronics circuit), size, harsh ambient, and cooling. Packaging for automotive lighting applications combining the advanced printed circuit board (PCB) technology with a multifunctional LED-based board is investigated with a focus on the effect of thermal conduction-based cooling for hot spot abatement. A baseline study with a flame retardant 4 technology, commonly known as FR4 PCB, is first compared with a metal-core PCB technology, both experimentally and computationally. The double-sided advanced PCB that houses both electronics and LEDs is then investigated computationally and experimentally compared with the baseline FR4 PCB. Computational models are first developed with a commercial computational fluid dynamics software and are followed by an advanced PCB technology based on embedded heat pipes, which is computationally and experimentally studied. Then, attention is turned to studying different heat pipe orientations and heat pipe placements on the board. Results show that conventional FR4-based light engines experience local hot spots (ΔT>50°C) while advanced PCB technology based on heat pipes and thermal spreaders eliminates these local hot spots (ΔT<10°C), leading to a higher lumen extraction with improved reliability. Finally, possible design options are presented with embedded heat pipe structures that further improve the PCB performance.

  5. Modeling the radiation pattern of LEDs.

    PubMed

    Moreno, Ivan; Sun, Ching-Cherng

    2008-02-04

    Light-emitting diodes (LEDs) come in many varieties and with a wide range of radiation patterns. We propose a general, simple but accurate analytic representation for the radiation pattern of the light emitted from an LED. To accurately render both the angular intensity distribution and the irradiance spatial pattern, a simple phenomenological model takes into account the emitting surfaces (chip, chip array, or phosphor surface), and the light redirected by both the reflecting cup and the encapsulating lens. Mathematically, the pattern is described as the sum of a maximum of two or three Gaussian or cosine-power functions. The resulting equation is widely applicable for any kind of LED of practical interest. We accurately model a wide variety of radiation patterns from several world-class manufacturers.

  6. Evaluation of LED vehicular and pedestrian modules.

    DOT National Transportation Integrated Search

    2009-04-01

    This study was conducted to verify the compliance of vehicular and pedestrian LED traffic signal modules with the Institute : of Transportation Engineers specifications; and to assess drivers preferences of the LED modules. Four vehicular modules ...

  7. Demonstration Assessment of Light-Emitting Diode (LED) Parking Lot Lighting at T.J.Maxx in Manchester, NH Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Myer, Michael; Goettel, Russell T.

    2010-06-29

    A report describing the process and results of replacing existing parking lot lighting, looking at a LED option with occupancy sensors, and conventional alternates. Criteria include payback, light levels, occupant satisfaction. This report is Phase I of II. Phase I deals with initial installation.

  8. Mapping Student-Led Peer Learning in the UK

    ERIC Educational Resources Information Center

    Keenan, Chris

    2014-01-01

    Peer-led academic learning has increased in importance, but there is little sense of how many institutions support it, how they understand its purposes or what peer-led learning best practice is. This report examines the provision of peer-led learning in the UK. It identifies challenges and opportunities, including international perspectives and…

  9. Pathways to recovery (PTR): impact of peer-led group participation on mental health recovery outcomes.

    PubMed

    Fukui, Sadaaki; Davidson, Lori J; Holter, Mark C; Rapp, Charles A

    2010-01-01

    This study examined the positive effects on recovery outcomes for people with severe and persistent mental illness using peer-led groups based on Pathways to Recovery: A Strengths Recovery Self-Help Workbook (PTR). PTR translates the evidence-supported practice of the Strengths Model into a self-help approach, allowing users to identify and pursue life goals based on personal and environmental strengths. A single-group pretest-posttest research design was applied. Forty-seven members in 6 consumer-run organizations in one Midwestern state participated in a PTR peer-led group, completing a baseline survey before the group and again at the completion of the 12-week sessions. The Rosenberg Self-Esteem Scale, the General Self-Efficacy Scale, Multidimensional Scale of Perceived Social Support, the Spirituality Index of Well-Being, and the Modified Colorado Symptom Index were employed as recovery outcomes. Paired Hotelling's T-square test was conducted to examine the mean differences of recovery outcomes between the baseline and the completion of the group. Findings revealed statistically significant improvements for PTR participants in self-esteem, self-efficacy, social support, spiritual well-being, and psychiatric symptoms. This initial research is promising for establishing PTR as an important tool for facilitating recovery using a peer-led group format. The provision of peer-led service has been emphasized as critical to integrating consumers' perspectives in recovery-based mental health services. Given the current federal funding stream for peer services, continued research into PTR and other peer-led services becomes more important.

  10. LED mini-lidar as minimum setup

    NASA Astrophysics Data System (ADS)

    Shiina, Tatsuo

    2014-10-01

    The LED mini-lidar has been designed and demonstrated as the near range atmosphere monitoring, dust and gas detections. The LED lamp is used as a lidar light source. It is not a special one, and just used as a small status indicator or a spot luminaire. For the atmospheric monitoring in the near range of a few hundreds meters, the energy of 1nJ (=100mW/10ns) is enough for lidar observation in the nighttime. The LED lamp is excited at the high repetition frequency of < 1MHz. The signal-to-noise ratio can be increased by this high frequency even if the receiving photons are a little at each pulse. It is adequate because the spatiotemporal scale of the low-altitude atmosphere is small of a ten seconds and a few tens meters. To pursue such quick motion of the atmosphere and dust, the high-speed photon counter has been developed. It can act with BIN width of 4ns (Spatial resolution 0.6m) at the repetition frequency of <500kHz. The LED mini-lidar has been demonstrated to monitor the actual atmosphere of the observation range of <500m in the nighttime and <100m in the daytime with the receiving lens of 200mmφ. The interest approach is tired to distinguish the dust characteristics by using the counting rate of dust echoes. It is effective in the case that the dust material is given. And for trial, the LED mini-Raman-lidar is developed to monitor certain gas detection in near distance, too.

  11. Adapting radio technology to LED feedback systems

    NASA Astrophysics Data System (ADS)

    Salsbury, Marc; Ashdown, Ian

    2007-09-01

    Superheterodyne techniques were originally developed for radio transmission and reception nearly a century ago. In this paper we explore the adaptation of this technology to the problem of simultaneously monitoring the intensities of multiple LED channels with a single photosensor. The use of superheterodyne techniques obviates the need for multiple photosensors filters and tristimulus color filters to monitor the relative intensities of red, green, and blue LEDs. In addition, they alleviate the problems of electrical and optical noise, as well as the influence of ambient illumination on the photosensors. They can also be used to advantage with phosphor-coated white light LEDs in solid state lighting systems. Taking a broader view, the use of such techniques demonstrates the value of looking outside the realm of conventional LED power and control technologies when designing solid state lighting systems.

  12. Nitride micro-LEDs and beyond--a decade progress review.

    PubMed

    Jiang, H X; Lin, J Y

    2013-05-06

    Since their inception, micro-size light emitting diode (µLED) arrays based on III-nitride semiconductors have emerged as a promising technology for a range of applications. This paper provides an overview on a decade progresses on realizing III-nitride µLED based high voltage single-chip AC/DC-LEDs without power converters to address the key compatibility issue between LEDs and AC power grid infrastructure; and high-resolution solid-state self-emissive microdisplays operating in an active driving scheme to address the need of high brightness, efficiency and robustness of microdisplays. These devices utilize the photonic integration approach by integrating µLED arrays on-chip. Other applications of nitride µLED arrays are also discussed.

  13. Effects of Cryogenic Temperatures on LEDs and Optical Fiber

    NASA Technical Reports Server (NTRS)

    Pantel, Erica R.

    2005-01-01

    Light Emitting Diodes (LEDs) may provide a simple, low powered light source for future space missions. However, the effects of cryogenic temperatures on LEDs and optical fibers are largely unknown. Tests were performed on a selection of commercially-available LEDs, with wavelengths varying from 468 nm to 950 nm, as well as "white" LEDs. Dry ice and liquid nitrogen (LN2) were used to bring the LEDs to the desired temperatures. The optical fibers were tested using a specially-machined brass cylinder that would allow the fibers to be cooled slowly and evenly in an LN2 dewer. An optical fiber coupled to a spectrometer was used to acquired spectra of a calibration light source (wavelength range 253-922 nm) at various temperatures. Examination of the LED spectra has shown several different effects, depending on the LED in question. Those with wavelengths above 590 nm tend to show a "blue shift" in their peak wavelength and an increase in intensity. Other LEDs developed secondary or tertiary peaks, or showed no peak shift at all, although all LEDs did show an increase in observed intensity. The optical fiber showed a slight non-uniform decrease in transmission as the temperature cooled to -195 C.

  14. Testing high brightness LEDs relative to application environment

    NASA Astrophysics Data System (ADS)

    Singer, Jeffrey; Mangum, Scott; Lundberg, John

    2006-08-01

    Application of light emitting diodes is expanding as the luminous output and efficiencies of these devices improve. At the same time, the number of LED package types is increasing, making it challenging to determine the appropriate device for use in lighting product designs. A range of factors should be considered when selecting a LED for an application including color coordinates, luminous efficacy, cost, lumen maintenance, application life, packaging and manufacturability. Additional complexities can be introduced as LED packages become obsolete and replacement parts must be selected. The replacement LED characteristics must be understood and assessed against the parameters of the original device, in order to determine if the change will be relatively simple or will force other end-product changes. While some characteristics are readily measured and compared, other factors, such as lumen maintenance, are difficult to verify. This paper will discuss the characteristics of a LED that should be considered during the design process as well as methods to validate these characteristics, particularly those which are not typically on data sheets or, are critical to the design and warrant additional validation. Particular attention will be given to LED lumen maintenance. While published manufacturer data typically provides temperature versus performance curves, the data may not be useful depending upon the application's operating environment. Models must be created to estimate the LED's junction temperature and degradation curve at the applied temperature in order to develop a more precise life estimate. This paper presents one approach to a LED device life and performance study designed with application environments in mind.

  15. LED traffic signal lamp characteristics : executive summary.

    DOT National Transportation Integrated Search

    2002-05-01

    LED traffic signal lamps are being used to replace incandescent traffic signal lamps because of the long-term cost saving associated with reduced energy consumption and longer service life. The are reasons to believe that the use of LED traffic signa...

  16. LED traffic signal lamp characteristics : final report.

    DOT National Transportation Integrated Search

    2002-05-01

    LED traffic signal lamps are being used to replace incandescent traffic signal lamps because of : the long-term cost saving associated with reduced energy consumption and longer service life. The are reasons to believe that the use of LED traffic sig...

  17. Surface photonic crystal structures for LED emission modification

    NASA Astrophysics Data System (ADS)

    Uherek, Frantisek; Škriniarová, Jaroslava; Kuzma, Anton; Šušlik, Łuboš; Lettrichova, Ivana; Wang, Dong; Schaaf, Peter

    2017-12-01

    Application of photonic crystal structures (PhC) can be attractive for overall and local enhancement of light from patterned areas of the light emitting diode (LED) surface. We used interference and near-field scanning optical microscope lithography for patterning of the surface of GaAs/AlGaAs based LEDs emitted at 840 nm. Also new approach with patterned polydimethylsiloxane (PDMS) membrane applied directly on the surface of red emitting LED was investigated. The overall emission properties of prepared LED with patterned structure show enhanced light extraction efficiency, what was documented from near- and far-field measurements.

  18. A review of passive thermal management of LED module

    NASA Astrophysics Data System (ADS)

    Huaiyu, Ye; Koh, Sau; van Zeijl, Henk; Gielen, A. W. J.; Guoqi, Zhang

    2011-01-01

    Recently, the high-brightness LEDs have begun to be designed for illumination application. The increased electrical currents used to drive LEDs lead to thermal issues. Thermal management for LED module is a key design parameter as high operation temperature directly affects their maximum light output, quality, reliability and life time. In this review, only passive thermal solutions used on LED module will be studied. Moreover, new thermal interface materials and passive thermal solutions applied on electronic equipments are discussed which have high potential to enhance the thermal performance of LED Module.

  19. Determination of LEDs degradation with entropy generation rate

    NASA Astrophysics Data System (ADS)

    Cuadras, Angel; Yao, Jiaqiang; Quilez, Marcos

    2017-10-01

    We propose a method to assess the degradation and aging of light emitting diodes (LEDs) based on irreversible entropy generation rate. We degraded several LEDs and monitored their entropy generation rate ( S ˙ ) in accelerated tests. We compared the thermoelectrical results with the optical light emission evolution during degradation. We find a good relationship between aging and S ˙ (t), because S ˙ is both related to device parameters and optical performance. We propose a threshold of S ˙ (t) as a reliable damage indicator of LED end-of-life that can avoid the need to perform optical measurements to assess optical aging. The method lays beyond the typical statistical laws for lifetime prediction provided by manufacturers. We tested different LED colors and electrical stresses to validate the electrical LED model and we analyzed the degradation mechanisms of the devices.

  20. A comparison of pediatric basic life support self-led and instructor-led training among nurses.

    PubMed

    Vestergaard, Lone D; Løfgren, Bo; Jessen, Casper L; Petersen, Christina B; Wolff, Anne; Nielsen, Henrik V; Krarup, Niels H V

    2017-02-01

    Pediatric cardiac arrest carries a poor prognosis. Basic life support improves survival. Studies on pediatric basic life support (PBLS) training are sparse. The aim of our study was to investigate the effect of self-training in PBLS. We conducted a prospective controlled trial enrolling nurses from pediatric and maternity wards (n=29 in each group). Self-training, including a manikin and access to a web-based video on PBLS, was compared with a 2-h instructor-led course. Two weeks after training, all participants were tested in a mock scenario of pediatric cardiac arrest. Fifteen parameters equivalent to the steps in the PBLS algorithm - for example, effective ventilations, effective chest compressions, calling for help, and correct sequence of actions, were evaluated and rated dichotomously (1=approved or 0=not approved). No difference was observed in the baseline demographics between the self-training group and the instructor-led group. The participants in the self-training group accessed the website 2±1.5 times (mean±SD) and spent 41±25 min on the site. There was no significant difference between the two groups in the overall average score (10.5 in the self-training group vs. 10.0 in the instructor-led group, P=0.51) or in any of the 15 parameters. After the study, all participants felt that they had improved their skills and felt capable of performing PBLS. Self-training is not statistically different to instructor-led training in teaching PBLS. Self-evaluated confidence improved, but showed no difference between groups. PBLS may be disseminated through self-training.

  1. Design of a cylindrical LED substrate without radiator

    NASA Astrophysics Data System (ADS)

    Tang, Fan; Guo, Zhenning

    2017-12-01

    To reduce the weight and production costs of light-emitting diode (LED) lamps, we applied the principle of the chimney effect to design a cylindrical LED substrate without a radiator. We built a 3D model by using Solidworks software and applied the flow simulation plug-in to conduct model simulation, thereby optimizing the heat source distribution and substrate thickness. The results indicate that the design achieved optimal cooling with a substrate with an upper extension length of 35 mm, a lower extension length of 8 mm, and a thickness of 1 mm. For a substrate of those dimensions, the highest LED chip temperature was 64.78 °C, the weight of the substrate was 35.09 g, and R jb = 7.00 K/W. If the substrate is powered at 8, 10, and 12 W, its temperature meets LED safety requirements. In physical tests, the highest temperature for a physical 8 W cylindrical LED substrate was 66 °C, which differed by only 1.22 °C from the simulation results, verifying the validity of the simulation. The designed cylindrical LED substrate can be used in high-power LED lamps that do not require radiators. This design is not only excellent for heat dissipation, but also for its low weight, low cost, and simplicity of manufacture.

  2. Primary care-led commissioning and public involvement in the English National Health Service. Lessons from the past.

    PubMed

    Petsoulas, Christina; Peckham, Stephen; Smiddy, Jane; Wilson, Patricia

    2015-05-01

    Patient and Public involvement (PPI) in health care occupies a central place in Western democracies. In England, this theme has been continuously prominent since the introduction of market reforms in the early 1990s. The health care reforms implemented by the current Coalition Government are making primary care practitioners the main commissioners of health care services in the National Health Service, and a duty is placed on them to involve the public in commissioning decisions and strategies. Since implementation of PPI initiatives in primary care commissioning is not new, we asked how likely it is that the new reforms will make a difference. We scanned the main literature related to primary care-led commissioning and found little evidence of effective PPI thus far. We suggest that unless the scope and intended objectives of PPI are clarified and appropriate resources are devoted to it, PPI will continue to remain empty rhetoric and box ticking. To examine the effect of previous PPI initiatives on health care commissioning and draw lessons for future development. We scanned the literature reporting on previous PPI initiatives in primary care-led commissioning since the introduction of the internal market in 1991. In particular, we looked for specific contexts, methods and outcomes of such initiatives. 1. PPI in commissioning has been constantly encouraged by policy makers in England. 2. Research shows limited evidence of effective methods and outcomes so far. 3. Constant reconfiguration of health care structures has had a negative impact on PPI. 4. The new structures look hardly better poised to bring about effective public and patient involvement.

  3. LED Solar Simulator

    NASA Image and Video Library

    2016-11-18

    NASA Glenn's new LED solar simulator was developed by Angstrom Designs and UC Santa Barbara under a Small Business Innovative Research program to test the next generation of high-efficiency space solar cells for future missions. The new simulator contains over 1500 individually adjustable light sources, most of which emit light invisible to the human eye, to cover a 10 x10 foot area.

  4. LED Solar Simulator

    NASA Image and Video Library

    2016-11-16

    NASA Glenn's new LED solar simulator was developed by Angstrom Designs and UC Santa Barbara under a Small Business Innovative Research program to test the next generation of high-efficiency space solar cells for future missions. The new simulator contains over 1500 individually adjustable light sources, most of which emit light invisible to the human eye, to cover a 10 x10 foot area.

  5. Exploring the use of student-led simulated practice learning in pre-registration nursing programmes.

    PubMed

    Brown, Jo; Collins, Guy; Gratton, Olivia

    2017-09-20

    Simulated practice learning is used in pre-registration nursing programmes to replicate situations that nursing students are likely to encounter in clinical practice, but in a safe and protected academic environment. However, lecturer-led simulated practice learning has been perceived as detached from contemporary nursing practice by some nursing students. Therefore, a pilot project was implemented in the authors' university to explore the use of student-led simulated practice learning and its potential benefits for nursing students. To evaluate the effectiveness of student-led simulated practice learning in pre-registration nursing programmes. The authors specifically wanted to: enhance the students' skills; improve their critical thinking and reflective strategies; and develop their leadership and management techniques. A literature review was undertaken to examine the evidence supporting student-led simulated practice learning. A skills gap analysis was then conducted with 35 third-year nursing students to identify their learning needs, from which suitable simulated practice learning scenarios and sessions were developed and undertaken. These sessions were evaluated using debriefs following each of the sessions, as well as informal discussions with the nursing students. The pilot project identified that student-led simulated learning: developed nursing students' ability to plan and facilitate colleagues' practice learning; enabled nursing students to develop their mentoring skills; reinforced the nursing students' self-awareness, which contributed to their personal development; and demonstrated the importance of peer feedback and support through the debriefs. Challenges included overcoming some students' resistance to the project and that some lecturers were initially concerned that nursing students may not have the clinical expertise to lead the simulated practice learning sessions effectively. This pilot project has demonstrated how student-led simulated

  6. Progress in extremely high brightness LED-based light sources

    NASA Astrophysics Data System (ADS)

    Hoelen, Christoph; Antonis, Piet; de Boer, Dick; Koole, Rolf; Kadijk, Simon; Li, Yun; Vanbroekhoven, Vincent; Van De Voorde, Patrick

    2017-09-01

    Although the maximum brightness of LEDs has been increasing continuously during the past decade, their luminance is still far from what is required for multiple applications that still rely on the high brightness of discharge lamps. In particular for high brightness applications with limited étendue, e.g. front projection, only very modest luminance values in the beam can be achieved with LEDs compared to systems based on discharge lamps or lasers. With dedicated architectures, phosphor-converted green LEDs for projection may achieve luminance values up to 200-300 Mnit. In this paper we report on the progress made in the development of light engines based on an elongated luminescent concentrator pumped by blue LEDs. This concept has recently been introduced to the market as ColorSpark High Lumen Density LED technology. These sources outperform the maximum brightness of LEDs by multiple factors. In LED front projection, green LEDs are the main limiting factor. With our green modules, we now have achieved peak luminance values of 2 Gnit, enabling LED-based projection systems with over 4000 ANSI lm. Extension of this concept to yellow and red light sources is presented. The light source efficiency has been increased considerably, reaching 45-60 lm/W for green under practical application conditions. The module architecture, beam shaping, and performance characteristics are reviewed, as well as system aspects. The performance increase, spectral range extensions, beam-shaping flexibility, and cost reductions realized with the new module architecture enable a breakthrough in LED-based projection systems and in a wide variety of other high brightness applications.

  7. NASA Ames UV-LED Poster Overview

    NASA Technical Reports Server (NTRS)

    Jaroux, Belgacem Amar

    2015-01-01

    UV-LED is a small satellite technology demonstration payload being flown on the Saudisat-4 spacecraft that is demonstrating non-contacting charge control of an isolated or floating mass using new solid-state ultra-violet light emitting diodes (UV-LEDs). Integrated to the rest of the spacecraft and launched on a Dnepr in June 19, 2014, the project is a collaboration between the NASA Ames Research Center (ARC), Stanford University, and King Abdulaziz City for Science and Technology (KACST). Beginning with its commissioning in December, 2015, the data collected by UV-LED have validated a novel method of charge control that will improve the performance of drag-free spacecraft allowing for concurrent science collection during charge management operations as well as reduce the mass, power and volume required while increasing lifetime and reliability of a charge management subsystem. UV-LED continues to operate, exploring new concepts in non-contacting charge control and collecting data crucial to understanding the lifetime of ultra-violet light emitting diodes in space. These improvements are crucial to the success of ground breaking missions such as LISA and BBO, and demonstrates the ability of low cost small satellite missions to provide technological advances that far exceed mission costs.

  8. The possible ocular hazards of LED dental illumination applications.

    PubMed

    Stamatacos, Catherine; Harrison, Janet L

    2014-04-01

    The use of high-intensity illumination via Light-Emitting Diode (LED) headlamps is gaining in popularity with dentists and student dentists. Practitioners are using LED headlamps together with magnifying loupes, overhead LED illumination and fiber-optic dental handpieces for long periods of time. Although most manufacturers of these LED illuminators advertise that their devices emit "white" light, these still consist of two spectral bands - the blue spectral band, with its peak at 445 nm, and the green with its peak at 555 nm. While manufacturers suggest that their devices emit "white" light, spectral components of LED lights from different companies are significantly different. Dental headlamp manufacturers strive to create a white LED, and they advertise that this type of light emitted from their product offers bright white-light illumination. However, the manufacturing of a white LED light is done through selection of a white LED-type based on the peak blue strength in combination with the green peak strength and thus creating a beam-forming optic, which determines the beam quality. Some LED illuminators have a strong blue-light component versus the green-light component. Blue-light is highly energized and is close in the color spectrum to ultraviolet-light. The hazards of retinal damage with the use of high-intensity blue-lights has been well-documented. There is limited research regarding the possible ocular hazards of usage of high-intensity illuminating LED devices. Furthermore, the authors have found little research, standards, or guidelines examining the possible safety issues regarding the unique dental practice setting consisting of the combined use of LED illumination systems. Another unexamined component is the effect of high-intensity light reflective glare and magnification back to the practitioner's eyes due to the use of water during dental procedures. Based on the result of Dr. Janet Harrison's observations of beginning dental students in a

  9. The possible ocular hazards of LED dental illumination applications.

    PubMed

    Stamatacos, Catherine; Harrison, Janet L

    2013-01-01

    The use of high-intensity illumination via Light-Emitting Diode (LED) headlamps is gaining in popularity with dentists and student dentists. Practitioners are using LED headlamps together with magnifying loupes, overhead LED illumination and fiber-optic dental handpieces for long periods of time. Although most manufacturers of these LED illuminators advertise that their devices emit "white" light, these still consist of two spectral bands--the blue spectral band, with its peak at 445 nm, and the green with its peak at 555 nm. While manufacturers suggest that their devices emit "white" light, spectral components of LED lights from different companies are significantly different. Dental headlamp manufacturers strive to create a white LED, and they advertise that this type of light emitted from their product offers bright white-light illumination. However, the manufacturing of a white LED light is done through selection of a white LED-type based on the peak blue strength in combination with the green peak strength and thus creating a beam-forming optic, which determines the beam quality. Some LED illuminators have a strong blue-light component versus the green-light component. Blue-light is highly energized and is close in the color spectrum to ultraviolet-light. The hazards of retinal damage with the use of high-intensity blue-lights has been well-documented. There is limited research regarding the possible ocular hazards of usage of high-intensity illuminating LED devices. Furthermore, the authors have found little research, standards, or guidelines examining the possible safety issues regarding the unique dental practice setting consisting of the combined use of LED illumination systems. Another unexamined component is the effect of high-intensity light reflective glare and magnification back to the practitioner's eyes due to the use of water during dental procedures. Based on the result of Dr. Janet Harrison's observations of beginning dental students in a

  10. Design method of high-efficient 
LED headlamp lens.

    PubMed

    Chen, Fei; Wang, Kai; Qin, Zong; Wu, Dan; Luo, Xiaobing; Liu, Sheng

    2010-09-27

    Low optical efficiency of light-emitting diode (LED) based headlamp is one of the most important issues to obstruct applications of LEDs in headlamp. An effective high-efficient LED headlamp freeform lens design method is introduced in this paper. A low-beam lens and a high-beam lens for LED headlamp are designed according to this method. Monte Carlo ray tracing simulation results demonstrate that the LED headlamp with these two lenses can fully comply with the ECE regulation without any other lens or reflector. Moreover, optical efficiencies of both these two lenses are more than 88% in theory.

  11. Influencing of various phosphor parameters on the LED performance

    NASA Astrophysics Data System (ADS)

    Wu, Yi Ping; Zhang, Shu Qin; Jin, Shang-zhong; Shi, Chang Shou; Li, Liang; Yu, RenYong

    2012-10-01

    In this paper ,the advantages and disadvantages of the methods to achieve White LED are reviewed, and phosphor-converted white LEDs are discussed in detail. In the case of blue chip exciting YAG phosphor to get white LED, use Mie scattering theory to construct physical model, then analyze how the package, concentration, thickness and particle size of phosphor work on extraction efficiency, spatial Chroma uniformity and color temperature of white LED. The conclusion of this paper advances the application of LED solid-state light source. In the end, the paper puts forward the direction and focus of phosphor research.

  12. Affordable underwater wireless optical communication using LEDs

    NASA Astrophysics Data System (ADS)

    Pilipenko, Vladimir; Arnon, Shlomi

    2013-09-01

    In recent years the need for high data rate underwater wireless communication (WC) has increased. Nowadays, the conventional technology for underwater communication is acoustic. However, the maximum data rate that acoustic technology can provide is a few kilobits per second. On the other hand, emerging applications such as underwater imaging, networks of sensors and swarms of underwater vehicles require much faster data rates. As a result, underwater optical WC, which can provide much higher data rates, has been proposed as an alternative means of communication. In addition to high data rates, affordable communication systems become an important feature in the development requirements. The outcome of these requirements is a new system design based on off-the-shelf components such as blue and green light emitting diodes (LEDs). This is due to the fact that LEDs offer solutions characterized by low cost, high efficiency, reliability and compactness. However, there are some challenges to be met when incorporating LEDs as part of the optical transmitter, such as low modulation rates and non linearity. In this paper, we review the main challenges facing the incorporation of LEDs as an integral part of underwater WC systems and propose some techniques to mitigate the LED limitations in order to achieve high data rate communication

  13. Essentials for Successful and Widespread LED Lighting Adoption

    NASA Astrophysics Data System (ADS)

    Khan, Nisa

    2011-03-01

    Solid-state lighting (SSL), with light-emitting diodes (LEDs) as the light source, is a growing and essential field, particularly in regard to the heightened need for global energy efficiency. In recent years, SSL has experienced remarkable advances in efficiency, light output magnitude and quality. Thus such diverse applications as signage, message centers, displays, and special lighting are now adopting LEDs, taking 2010's market to 9.1 billion - 68% growth from the previous year! While this is promising, future growth in both display and lighting applications will rely upon unveiling deeper understanding and key innovations in LED lighting science and technologies. In this presentation, some LED lighting fundamentals, engineering challenges and novel solutions will be discussed to address reduction in efficiency (a.k.a. droop) at high currents, and to obtain uniform light distribution for overcoming LEDs' directional nature. The droop phenomenon has been a subject of much controversy in the industry and despite several studies and claims, a widely-accepted explanation still lacks because of counter arguments and experiments. Recently several research studies have identified that the droop behavior in nitride-based LEDs beyond certain current density ranges can only be comprehensively explained if the current leaking beyond the LED active region is included. Although such studies have identified a few useful current leakage mechanisms outside the active region, no one has included current leakage, due to non-ideal, 3-D device structures that create undesirable current distribution inside and outside the active region. This talk will address achieving desirable current distributions from optimized 3-D device structures that should reduce current leakage and hence the droop behavior. In addition to novel LED design solutions for droop reduction and uniform light distribution, the talk will address cost and yield concerns as they pertain to core material scarcity

  14. LED street lighting evaluation -- phase II : LED specification and life-cycle cost analysis.

    DOT National Transportation Integrated Search

    2015-01-01

    Phase II of this study focused on developing a draft specification for LED luminaires to be used by IDOT : and a life-cycle cost analysis (LCCA) tool for solid state lighting technologies. The team also researched the : latest developments related to...

  15. Flat-panel video resolution LED display system

    NASA Astrophysics Data System (ADS)

    Wareberg, P. G.; Kennedy, D. I.

    The system consists of a 128 x 128 element X-Y addressable LED array fabricated from green-emitting gallium phosphide. The LED array is interfaced with a 128 x 128 matrix TV camera. Associated electronics provides for seven levels of grey scale above zero with a grey scale ratio of square root of 2. Picture elements are on 0.008 inch centers resulting in a resolution of 125 lines-per-inch and a display area of approximately 1 sq. in. The LED array concept lends itself to modular construction, permitting assembly of a flat panel screen of any desired size from 1 x 1 inch building blocks without loss of resolution. A wide range of prospective aerospace applications exist extending from helmet-mounted systems involving small dedicated arrays to multimode cockpit displays constructed as modular screens. High-resolution LED arrays are already used as CRT replacements in military film-marking reconnaissance applications.

  16. Electrical efficiency and droop in MQW LEDs

    NASA Astrophysics Data System (ADS)

    Malyutenko, V. K.

    2014-02-01

    It is believed that low power conversion efficiency in commercial MQW LEDs occurs as a result of efficiency droop, current-induced dynamic degradation of the internal quantum efficiency, injection efficiency, and extraction efficiency. Broadly speaking, all these "quenching" mechanisms could be referred to as the optical losses. The vast advances of high-power InGaN and AlGaInP MQW LEDs have been achieved by addressing these losses. In contrast to these studies, in this paper we consider an alternative approach to make high-power LEDs more efficient. We identify current-induced electrical efficiency degradation (EED) as a strong limiting factor of power conversion efficiency. We found that EED is caused by current crowding followed by an increase in current-induced series resistance of a device. By decreasing the current spreading length, EED also causes the optical efficiency to degrade and stands for an important aspect of LED performance. This paper gives scientists the opportunity to look for different attributes of EED.

  17. Is light-emitting diode phototherapy (LED-LLLT) really effective?

    PubMed Central

    Kim, Won-Serk; Calderhead, R Glen

    2011-01-01

    Background: Low level light therapy (LLLT) has attracted attention in many clinical fields with a new generation of light-emitting diodes (LEDs) which can irradiate large targets. To pain control, the first main application of LLLT, have been added LED-LLLT in the accelerated healing of wounds, both traumatic and iatrogenic, inflammatory acne and the patient-driven application of skin rejuvenation. Rationale and Applications: The rationale behind LED-LLLT is underpinned by the reported efficacy of LED-LLLT at a cellular and subcellular level, particularly for the 633 nm and 830 nm wavelengths, and evidence for this is presented. Improved blood flow and neovascularization are associated with 830 nm. A large variety of cytokines, chemokines and macromolecules can be induced by LED phototherapy. Among the clinical applications, non-healing wounds can be healed through restoring the collagenesis/collagenase imbalance in such examples, and ‘normal’ wounds heal faster and better. Pain, including postoperative pain, postoperative edema and many types of inflammation can be significantly reduced. Experimental and clinical evidence: Some personal examples of evidence are offered by the first author, including controlled animal models demonstrating the systemic effect of 830 nm LED-LLLT on wound healing and on induced inflammation. Human patients are presented to illustrate the efficacy of LED phototherapy on treatment-resistant inflammatory disorders. Conclusions: Provided an LED phototherapy system has the correct wavelength for the target cells, delivers an appropriate power density and an adequate energy density, then it will be at least partly, if not significantly, effective. The use of LED-LLLT as an adjunct to conventional surgical or nonsurgical indications is an even more exciting prospect. LED-LLLT is here to stay. PMID:24155530

  18. Bridgeless SEPIC PFC Converter for Multistring LED Driver

    NASA Astrophysics Data System (ADS)

    Jha, Aman; Singh, Bhim

    2018-05-01

    This paper deals with Power Factor Correction (PFC) in Low Voltage High Current (LVHC) multi-string light emitting diode (LED) using a bridgeless (BL) single ended primary inductance converter (SEPIC). This application is designed for large area LED lighting with illumination control. A multi-mode LED dimming technique is used for the lighting control. The BL-SEPIC PFC converter is used as a load emulator for high power factor. The regulated low voltage from flyback converter is a source power to the synchronous buck converters for multi-string LED driver and forced cooling system for LED junction. The BL-SEPIC PFC converter inductor design is based on Discontinuous Inductor Current Modes (DICM) which provides good PFC at low cost. Test results are found quite satisfactory for universal input AC (90-265 V). There is significant improvement in the power factor and input current Total Harmonic Distortion (THD) with good margin of harmonic limits for lighting IEC 61000-3-2 Class C.

  19. LED Device Illuminates New Path to Healing

    NASA Technical Reports Server (NTRS)

    2008-01-01

    Among NASA s research goals is increased understanding of factors affecting plant growth, including the effects of microgravity. Impeding such studies, traditional light sources used to grow plants on Earth are difficult to adapt to space flight, as they require considerable amounts of power and produce relatively large amounts of heat. As such, an optimized experimental system requires much less energy and reduces temperature variance without negatively affecting plant growth results. Ronald W. Ignatius, founder and chairman of the board at Quantum Devices Inc. (QDI), of Barneveld, Wisconsin, proposed using light-emitting diodes (LEDs) as the photon source for plant growth experiments in space. This proposition was made at a meeting held by the Wisconsin Center for Space Automation and Robotics, a NASA-sponsored research center that facilitates the commercialization of robotics, automation, and other advanced technologies. The Wisconsin group teamed with QDI to determine whether an LED system could provide the necessary wavelengths and intensities for photosynthesis, and the resultant system proved successful. The center then produced the Astroculture3, a plant growth chamber that successfully incorporated this LED light source, which has now flown on several space shuttle missions. NASA subsequently identified another need that could be addressed with the use of LEDs: astronaut health. A central concern in astronaut health is maintaining healthy growth of cells, including preventing bone and muscle loss and boosting the body s ability to heal wounds all adversely affected by prolonged weightlessness. Thus, having determined that LEDs can be used to grow plants in space, NASA decided to investigate whether LEDs might be used for photobiomodulation therapy (PBMT).

  20. Self-aligning LED-based optical link

    NASA Astrophysics Data System (ADS)

    Shen, Thomas C.; Drost, Robert J.; Rzasa, John R.; Sadler, Brian M.; Davis, Christopher C.

    2016-09-01

    The steady advances in light-emitting diode (LED) technology have motivated the use of LEDs in optical wireless communication (OWC) applications such as indoor local area networks (LANs) and communication between mobile platforms (e.g., robots, vehicles). In contrast to traditional radio frequency (RF) wireless communication, OWC utilizes electromagnetic spectrum that is largely unregulated and unrestricted. OWC communication may be especially useful in RF-denied environments, in which RF communication may be prohibited or undesirable. However, OWC does present some challenges, including the need to maintain alignment between potentially moving nodes. We describe a novel system for link alignment that is composed of a hyperboloidal mirror, camera, and gimbal. The experimental system is able to use the mirror and camera to detect an LED beacon of a neighboring node and estimate its bearing (azimuth and elevation), point the gimbal towards the beacon, and establish an optical link.

  1. The impact of an inflammatory bowel disease nurse-led biologics service

    PubMed Central

    Taylor, Nicola S; Bettey, Marion; Wright, Julia; Underhill, Caron; Kerr, Sarah; Perry, Kim; Cummings, JR Fraser

    2016-01-01

    Introduction Southampton General Hospital provides inflammatory bowel disease (IBD) services for a population of 650 000. Biological agents have impacted hugely on IBD but are costly drugs requiring careful supervision. These challenges led us to develop a specialist nurse-led biologics service to improve patient care. Method A 2010 case note audit highlighted areas for improvement in monitoring biologics and follow-up. A business case was developed to establish an IBD nurse to ensure identification and appropriate screening, education and review of biologics patients. A gain share was agreed with the local Care Commissioning Group (CCG) and £60 000 invested. Outcomes were reaudited in 2014. Results Biologic use has grown rapidly from 90 patients in 2011 to 330 in 2014. All records are now kept in a centralised database. Infection screening improved from 79% to 100%. In 2014, 96% of patients had follow-up ≤4 months post-induction to assess response, but two patients were seen at 7 months. 80% were followed up again at 9–12 months (100% at 9–14 months), all with treatment decisions. The initial investment was recouped via commissioners funding 368 additional outpatient appointments and 35 colonoscopies. Savings represented 15% total yearly biologic costs. Conclusions The introduction of the IBD biologics nurse-led service resulted in significant gains in care quality and costs. The need for improved follow-up of patients on biologics reflects increased pressures on clinic resources across the country. With continued biologics expansion, the introduction of a biologics nurse has provided invaluable support to patients and the IBD team at Southampton General Hospital. PMID:28839869

  2. Integrated parabolic nanolenses on MicroLED color pixels

    NASA Astrophysics Data System (ADS)

    Demory, Brandon; Chung, Kunook; Katcher, Adam; Sui, Jingyang; Deng, Hui; Ku, Pei-Cheng

    2018-04-01

    A parabolic nanolens array coupled to the emission of a nanopillar micro-light emitting diode (LED) color pixel is shown to reduce the far field divergence. For a blue wavelength LED, the total emission is 95% collimated within a 0.5 numerical aperture zone, a 3.5x improvement over the same LED without a lens structure. This corresponds to a half-width at half-maximum (HWHM) line width reduction of 2.85 times. Using a resist reflow and etchback procedure, the nanolens array dimensions and parabolic shape are formed. Experimental measurement of the far field emission shows a HWHM linewidth reduction by a factor of 2x, reducing the divergence over the original LED.

  3. Integrated parabolic nanolenses on MicroLED color pixels.

    PubMed

    Demory, Brandon; Chung, Kunook; Katcher, Adam; Sui, Jingyang; Deng, Hui; Ku, Pei-Cheng

    2018-04-20

    A parabolic nanolens array coupled to the emission of a nanopillar micro-light emitting diode (LED) color pixel is shown to reduce the far field divergence. For a blue wavelength LED, the total emission is 95% collimated within a 0.5 numerical aperture zone, a 3.5x improvement over the same LED without a lens structure. This corresponds to a half-width at half-maximum (HWHM) line width reduction of 2.85 times. Using a resist reflow and etchback procedure, the nanolens array dimensions and parabolic shape are formed. Experimental measurement of the far field emission shows a HWHM linewidth reduction by a factor of 2x, reducing the divergence over the original LED.

  4. Characteristics of white LED transmission through a smoke screen

    NASA Astrophysics Data System (ADS)

    Zheng, Yunfei; Yang, Aiying; Feng, Lihui; Guo, Peng

    2018-01-01

    The characteristics of white LED transmission through a smoke screen is critical for visible light communication through a smoke screen. Based on the Mie scattering theory, the Monte Carlo transmission model is established. Based on the probability density function, the white LED sampling model is established according to the measured spectrum of a white LED and the distribution angle of the lambert model. The sampling model of smoke screen particle diameter is also established according to its distribution. We simulate numerically the influence the smoke thickness, the smoke concentration and the angle of irradiance of white LED on transmittance of the white LED. We construct a white LED smoke transmission experiment system. The measured result on the light transmittance and the smoke concentration agreed with the simulated result, and demonstrated the validity of simulation model for visible light transmission channel through a smoke screen.

  5. Effect of different photo-initiators and light curing units on degree of conversion of composites.

    PubMed

    Brandt, William Cunha; Schneider, Luis Felipe Jochims; Frollini, Elisabete; Correr-Sobrinho, Lourenço; Sinhoreti, Mário Alexandre Coelho

    2010-01-01

    The aim of this study was to evaluate: (i) the absorption of photo-initiators and emission spectra of light curing units (LCUs); and (ii) the degree of conversion (DC) of experimental composites formulated with different photo-initiators when activated by different LCUs. Blends of BisGMA, UDMA, BisEMA and TEGDMA with camphorquinone (CQ) and/ or 1-phenyl-1,2-propanedione (PPD) were prepared. Dimethylaminoethyl methacrylate (DMAEMA) was used as co-initiator. Each mixture was loaded with 65 wt% of silanated filler particles. One quartz-tungsten-halogen - QTH (XL 2500, 3M/ESPE) and two lightemitting diode (LED) LCUs (UltraBlue IS, DMC and UltraLume LED 5, Ultradent) were used for activation procedures. Irradiance (mW/cm²) was calculated by the ratio of the output power by the area of the tip, and spectral distribution with a spectrometer (USB 2000). The absorption curve of each photo-initiator was determined using a spectrophotometer (Varian Cary 5G). DC was assessed by Fourier transformed infrared spectroscopy. Data were submitted to two-way ANOVA and Tukey's test (5%). No significant difference was found for DC values when using LED LCUs regardless of the photo-initiator type. However, PPD showed significantly lower DC values than composites with CQ when irradiated with QTH. PPD produced DC values similar to those of CQ, but it was dependent on the LCU type.

  6. Radiographer-led plan selection for bladder cancer radiotherapy: initiating a training programme and maintaining competency.

    PubMed

    McNair, H A; Hafeez, S; Taylor, H; Lalondrelle, S; McDonald, F; Hansen, V N; Huddart, R

    2015-04-01

    The implementation of plan of the day selection for patients receiving radiotherapy (RT) for bladder cancer requires efficient and confident decision-making. This article describes the development of a training programme and maintenance of competency. Cone beam CT (CBCT) images acquired on patients receiving RT for bladder cancer were assessed to establish baseline competency and training needs. A training programme was implemented, and observers were asked to select planning target volumes (PTVs) on two groups of 20 patients' images. After clinical implementation, the PTVs chosen were reviewed offline, and an audit performed after 3 years. A mean of 73% (range, 53-93%) concordance rate was achieved prior to training. Subsequent to training, the mean score decreased to 66% (Round 1), then increased to 76% (Round 2). Six radiographers and two clinicians successfully completed the training programme. An independent observer reviewed the images offline after clinical implementation, and a 91% (126/139) concordance rate was achieved. During the audit, 125 CBCT images from 13 patients were reviewed by a single observer and concordance was 92%. Radiographer-led selection of plan of the day was implemented successfully with the use of a training programme and continual assessment. Quality has been maintained over a period of 3 years. The training programme was successful in achieving and maintaining competency for a plan of the day technique.

  7. LED downlights with non-circular spots

    NASA Astrophysics Data System (ADS)

    Parkyn, William A.; Pelka, David G.

    2005-09-01

    The ubiquitous downlight inhabits our ceilings by the millions. Hot, inefficient, and electrically wasteful, it is next in line for replacement by the latest high-brightness, high-efficacy white LEDs. The conventional downlight configuration of a large incandescent spotlight in a low-cost, ceiling-recessed metal can, represents the culmination of old technology, fated never to improve significantly. Incandescent downlights add greatly both to direct and indirect electrical consumption, with the lamps requiring relatively frequent replacement. The small size of LED emitters means small optical elements can produce much higher-quality beams than incandescent spotlight-lamps can produce. Herein we introduce compact high-luminosity LED downlights with lenses that deliver uniform illumination to delimited targets such as tables. One version utilizes circular lenses and micro-diffuser films to deliver square outputs. The other uses lenses cut to the target shape. In particular, one of these lenses is the first to offer a semicircular spot suitable for gambling tables.

  8. Visual ergonomic evaluations on four different designs of LED traffic signs

    NASA Astrophysics Data System (ADS)

    Chen, Yi-Chun; Huang, Ting-Yuan; Lee, Tsung-Xian; Sun, Ching-Cherng

    2017-08-01

    To investigate the legibility and visual comfort of LED traffic signs, an ergonomic experiment is performed on four custom-designed LED traffic signs, including three self-luminous ones as LED lightbox, LED backlight and regional LED backlight, and one non-self-luminous sign with external LED lighting. The four signs are hanged side-by-side and evaluated by observers through questionnaires. The signage dimension is one-sixth of the real freeway traffic signs, and the observation distance is 25 m. The luminance of three self-luminous signs is 216 cd/m2. The illuminance of external LED lighting is 400 lux on the traffic sign. The ambient illuminance is 2.8 and 6.0 lux in two rounds. The results show that self-luminous traffic signs provide superior legibility, visual comfort and user preference than the non-self-luminous one. Among the three self-luminous signs, regional LED backlight is most susceptible to the ambient illumination. LED lightbox has significantly better preference score than LED backlight under darker ambient lighting. Only LED lightbox has significantly better visual comfort than external LED lighting in the brighter environment. Based on the four LED traffic signs evaluated in this study, we suggest LED lightbox as the prior choice. Further investigations on the effect of ambient illumination and other designs of self-luminous traffic signs are in progress.

  9. High-luminance LEDs replace incandescent lamps in new applications

    NASA Astrophysics Data System (ADS)

    Evans, David L.

    1997-04-01

    The advent of high luminance AlInGaP and InGaN LED technologies has prompted the use of LED devices in new applications formally illuminated by incandescent lamps. The luminous efficiencies of these new LED technologies equals or exceeds that attainable with incandescent sources, with reliability factors that far exceed those of incandescent sources. The need for a highly efficient, dependable, and cost effective replacement for incandescent lamps is being fulfilled with high luminance LED lamps. This paper briefly described some of the new applications incorporating high luminance LED lamps, traffic signals and roadway signs for traffic management, automotive exterior lighting, active matrix and full color displays for commercial advertising, and commercial aircraft panel lighting and military aircraft NVG compatible lighting.

  10. Automated platform for determination of LEDs spatial radiation pattern

    NASA Astrophysics Data System (ADS)

    Vladescu, Marian; Vuza, Dan Tudor

    2015-02-01

    Nowadays technologies lead to remarkable properties of the light-emitting diodes (LEDs), making them attractive for more and more applications, such as: interior and exterior lighting, outdoor LED panels, traffic signals, automotive (tail and brake lights, backlighting in dashboard and switches), backlighting of display panels, LCD displays, symbols on switches, keyboards, graphic boards and measuring scales. Usually, LEDs are small light sources consisting of a chip placed into a package, which may bring additional optics to this encapsulated ensemble, resulting in a less or more complex spatial distribution of the light intensity, with particular radiation patterns. This paper presents an automated platform designed to allow a quick and accurate determination of the spatial radiation patterns of LEDs encapsulated in various packages. Keywords: LED, luminous

  11. Evaluating white LEDs for outdoor landscape lighting application

    NASA Astrophysics Data System (ADS)

    Shakir, Insiya; Narendran, Nadarajah

    2002-11-01

    A laboratory experiment was conducted to understand the acceptability of different white light emitting diodes (LEDs) for outdoor landscape lighting. The study used a scaled model setup. The scene was designed to replicate the exterior of a typical upscale suburban restaurant including the exterior facade of the building, an approach with steps, and a garden. The lighting was designed to replicate light levels commonly found in nighttime outdoor conditions. The model had a central dividing partition with symmetrical scenes on both sides for side-by-side evaluations of the two scenes with different light sources. While maintaining equal luminance levels and distribution between the two scenes, four types of light sources were evaluated. These include, halogen, phosphor white LED, and two white light systems using RGB LEDs. These light sources were tested by comparing two sources at a time placed side-by-side and by individual assessment of each lighting condition. The results showed that the RGB LEDs performed equal or better than the most widely used halogen light source in this given setting. A majority of the subjects found slightly dimmer ambient lighting to be more typical for restaurants and therefore found RGB LED and halogen light sources to be more inviting. The phosphor white LEDs made the space look brighter, however a majority of the subjects disliked them.

  12. LEDs/ALAN-Working To Be Good Neighbors

    NASA Astrophysics Data System (ADS)

    Adams, Robert

    2015-08-01

    ALAN (Artificial Light At Night) and LEDs have recently become major discussion topics in the areas of astronomy, light pollution, endangered species and human health to mention but a few. In years past, MH, LPS and HPS dominated night lighting with LPS and its associated narrow spectrum as the preferred source around observatories and shorelines. LEDs offer the ability to modify the spectrum, realize substantial energy savings and other associated benefits while meeting the requirements of the astronomy community.The primary concern of the different groups relates to blue light content of the LED. For astronomers, the molecular (Raleigh) scattering related to the blue light interferes with certain portions of the spectrum used for deep space studies. The ecologists studying various endangered species find blue and green light can be related to declining leatherback turtle population in certain areas of the world. Other animals ranging from bats to moths and other insects are now being studied to determine the effect of the blue light spectrum on their behavior. The impact of blue light on the human circadian rhythm and vision, especially in the older population, is being extensively studied today.This presentation will discuss the spectral power distribution (SPD) of various light sources, the performance of new LED solutions and how the SPD of these new LED’s can be adapted to address some of the issues raised by various constituencies. A discussion describing why some of the metrics used to describe standard lighting are not adequate for specifying the new LED solutions with the modified spectra will be included.Today, lighting plans and implementation are all too often based on opinions and limited data. The ensuing problems and repercussions make it imperative to collect accurate and thorough information. Data collection is now ongoing using a variety of techniques analyzing the “before” and “after” lighting results from the C of HI LED streetlight

  13. LED solution for E14 candle lamp

    NASA Astrophysics Data System (ADS)

    Li, Yun; Liu, Ye; Boonekamp, Erik P.; Shi, Lei; Mei, Yi; Jiang, Tan; Guo, Qing; Wu, Huarong

    2009-08-01

    On a short to medium term, energy efficient retrofit LED products can offer an attractive solution for traditional lamps replacement in existing fixtures. To comply with user expectations, LED retrofit lamps should not only have the same mechanical interface to fit (socket and shape), but also have the similar light effect as the lamps they replace. The decorative lighting segment shows the best conditions to meet these requirements on short term. In 2008, Philips Lighting Shanghai started with the development of an LED candle lamp for the replacement of a 15W Candle shape (B35 E14) incandescent bulb, which is used in e.g. chandeliers. In this decorative application the main objective is not to generate as much light as possible, but the application requires the lamp to have a comparable look and, primarily, the same light effect as the incandescent candle lamp. This effect can be described as sparkling light, and it has to be directed sufficiently downwards (i.e., in the direction of the base of the lamp). These requirements leave very limited room for optics, electronics, mechanics and thermal design to play with in the small outline of this lamp. The main voltage AC LED concept is chosen to save the space for driver electronics. However the size of the AC LED is relatively big, which makes the optical design challenging. Several optical solutions to achieve the required light effect, to improve the optical efficiency, and to simplify the system are discussed. A novel prismatic lens has been developed which is capable of transforming the Lambertian light emission from typical high power LEDs into a butter-fly intensity distribution with the desired sparkling light effect. Thanks to this lens no reflecting chamber is needed, which improves the optical efficiency up to 70%, while maintaining the compact feature of the original optics. Together with advanced driver solution and thermal solution, the resulting LED candle lamp operates at 230V, consumes 1.8W, and

  14. LED module with high index lens

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bierhuizen, Serge J.; Wang, Nanze Patrick; Eng, Gregory W.

    2016-07-05

    An array of housings with housing bodies and lenses is molded, or an array of housing bodies is molded and bonded with lenses to form an array of housings with housing bodies and lenses. Light-emitting diodes (LEDs) are attached to the housings in the array. An array of metal pads may be bonded to the back of the array or insert molded with the housing array to form bond pads on the back of the housings. The array is singulated to form individual LED modules.

  15. Clinician-led, peer-led, and internet-delivered dissonance-based eating disorder prevention programs: Acute effectiveness of these delivery modalities.

    PubMed

    Stice, Eric; Rohde, Paul; Shaw, Heather; Gau, Jeff M

    2017-09-01

    Because independent trials have provided evidence for the efficacy and effectiveness of the dissonance-based Body Project eating disorder prevention program, the present trial tested whether clinicians produce the largest intervention effects, or whether delivery can be task-shifted to less expensive undergraduate peer educators or to Internet delivery without effect size attenuation, focusing on acute effects. In this study, 680 young women (M age = 22.2 years, SD = 7.1) recruited at colleges in 2 states were randomized to clinician-led Body Project groups, peer-led Body Project groups, the Internet-based eBody Project, or an educational video control condition. Participants in all 3 variants of the Body Project intervention showed significantly greater reductions in eating disorder risk factors and symptoms than did educational video controls. Participants in clinician-led and peer-led Body Project groups showed significantly greater reductions in risk factors than did eBody Project participants, but effects for the 2 types of groups were similar. Eating disorder onset over 7-month follow-up was significantly lower for peer-led Body Project group participants versus eBody Project participants (2.2% vs. 8.4%) but did not differ significantly between other conditions. The evidence that all 3 dissonance-based prevention programs outperformed an educational video condition, that both group-based interventions outperformed the Internet-based intervention in risk factor reductions, and that the peer-led groups showed lower eating disorder onset over follow-up than did the Internet-based intervention is novel. These acute-effects data suggest that both group-based interventions produce superior eating disorder prevention effects than does the Internet-based intervention and that delivery can be task-shifted to peer leaders. (PsycINFO Database Record (c) 2017 APA, all rights reserved).

  16. Vertical Root Fracture initiation in curved roots after root canal preparation: A dentinal micro-crack analysis with LED transillumination

    PubMed Central

    Martín-Biedma, Benjamín; Varela-Patiño, Purificación; Ruíz-Piñón, Manuel; Castelo-Baz, Pablo

    2017-01-01

    Background One of the causative factors of root defects is the increased friction produced by rotary instrumentation. A high canal curvature may increase stress, making the tooth more susceptible to dentinal cracks. The purpose of this study was to evaluate dentinal micro-crack formation with the ProTaper NEXT and ProTaper Universal systems using LED transillumination, and to analyze the micro-crack generated at the point of maximum canal curvature. Material and Methods 60 human mandibular premolars with curvatures between 30–49° and radii between 2–4 mm were used. The root canals were instrumented using the Protaper Universal® and Protaper NEXT® systems, with the aid of the Proglider® system. The obtained samples were sectioned transversely before subsequent analysis with LED transillumination at 2 mm and 8 mm from the apex and at the point of maximum canal curvature. Defects were scored: 0 for no defects; and 1 for micro-cracks. Results Root defects were not observed in the control group. The ProTaper NEXT system caused fewer defects (16.7%) than the ProTaper Universal system (40%) (P<0.05). The ProTaper Universal system caused significantly more micro-cracks at the point of maximum canal curvature than the ProTaper NEXT system (P<0.05). Conclusions Rotary instrumentation systems often generate root defects, but the ProTaper NEXT system generated fewer dentinal defects than the ProTaper Universal system. A higher prevalence of defects was found at the point of maximum curvature in the ProTaper Universal group. Key words:Curved root, Micro-crack, point of maximum canal curvature, ProTaper NEXT, ProTaper Universal, Vertical root fracture. PMID:29167712

  17. LEDs: DOE Programs Add Credibility to a Developing Technology

    ERIC Educational Resources Information Center

    Conbere, Susan

    2009-01-01

    LED (light-emitting diode) technology is moving fast, and with justification, some facility managers have viewed it with a wary eye. Some LEDs on the market do not perform as promised, and the technology is changing rapidly. But new developments from the U.S. Department of Energy (DOE) now make it easier for facility managers to find LEDs that…

  18. Computer-Based Experiment for Determining Planck's Constant Using LEDs

    ERIC Educational Resources Information Center

    Zhou, Feng; Cloninger, Todd

    2008-01-01

    Visible light emitting diodes (LEDs) have been widely used as power indicators. However, after the power is switched off, it takes a while for the LED to go off. Many students were fascinated by this simple demonstration. In this paper, by making use of computer-based data acquisition and modeling, we show the voltage across the LED undergoing an…

  19. Development and Performance Assessment of White LED Dimmer

    NASA Astrophysics Data System (ADS)

    Maiti, Pradip Kr.; Roy, Biswanath

    2017-10-01

    A microcontroller based electronic dimmer is developed using pulse width modulation technique. This dimmer is controllable by infra-red remote within a distance of 4 m and can be electrically connected between LED module and its driver. The performance of a developed LED dimmer is assessed on basis of variation of the photometric parameters of commercially available warm white and cool white LED luminaire used in indoor lighting applications. Four equally spaced dimming levels are considered to measure luminous efficacy, spectral power distribution, CIE 1931 chromaticity coordinates, CIE 1976 CIELUV color difference, correlated color temperature, general color rendering index and one specific color rendering index for saturated red color sample. Variations of above parameters are found out with reference to the values measured at rated voltage without the developed dimmer. Analysis of experimentally measured data shows that the developed LED dimmer is capable to vary light output of the WLED luminaire within a range of 25-100% without appreciable variation of its photometric and color parameters. The only exception is observed for the luminous efficacy parameter where it shows about 17 and 14.7% reduction for warm white and cool white LED luminaire at 25% dimming level.

  20. Monolithic LED arrays, next generation smart lighting sources

    NASA Astrophysics Data System (ADS)

    Lagrange, Alexandre; Bono, Hubert; Templier, François

    2016-03-01

    LED have become the main light sources of the future as they open the path for intelligent use of light in time, intensity and color. In many usages, strong energy economy is done by adjusting these properties. The smart lighting has three dimensions, energy efficiency brought by GaN blue emitting LEDs, integration of electronics, sensors, microprocessors in the lighting system and development of new functionalities and services provided by the light. Monolithic LED arrays allow two major innovations, the spatial control of light emission and the adjustment of the electrical properties of the source.

  1. Surviving Nuclear Winter Towards a Service-Led Business

    NASA Astrophysics Data System (ADS)

    Rocha, Michael; Chou, Timothy

    During the tech-led recession in 2001 a little known transformation occurred at the world's largest business software company. This transformation was led by a realization that existing customers of mature software need service of the products they purchased more than just purchasing new products. Organizing around the installed base of customers both defined new organizations, as well as new technology to power the specialists. This paper both gives a glimpse of the Oracle transformation as well as lays out some fundamental tenants of anyone interested in a service-led business.

  2. Regression analysis for LED color detection of visual-MIMO system

    NASA Astrophysics Data System (ADS)

    Banik, Partha Pratim; Saha, Rappy; Kim, Ki-Doo

    2018-04-01

    Color detection from a light emitting diode (LED) array using a smartphone camera is very difficult in a visual multiple-input multiple-output (visual-MIMO) system. In this paper, we propose a method to determine the LED color using a smartphone camera by applying regression analysis. We employ a multivariate regression model to identify the LED color. After taking a picture of an LED array, we select the LED array region, and detect the LED using an image processing algorithm. We then apply the k-means clustering algorithm to determine the number of potential colors for feature extraction of each LED. Finally, we apply the multivariate regression model to predict the color of the transmitted LEDs. In this paper, we show our results for three types of environmental light condition: room environmental light, low environmental light (560 lux), and strong environmental light (2450 lux). We compare the results of our proposed algorithm from the analysis of training and test R-Square (%) values, percentage of closeness of transmitted and predicted colors, and we also mention about the number of distorted test data points from the analysis of distortion bar graph in CIE1931 color space.

  3. Scalable, Economical Fabrication Processes for Ultra-Compact Warm-White LEDs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lowes, Ted

    Conventional warm-white LED component fabrication consists of a large number of sequential steps which are required to incorporate electrical, mechanical, and optical functionality into the component. Each of these steps presents cost and yield challenges which multiply throughout the entire process. Although there has been significant progress in LED fabrication over the last decade, significant advances are needed to enable further reductions in cost per lumen while not sacrificing efficacy or color quality. Cree conducted a focused 18-month program to develop a new low-cost, high-efficiency light emitting diode (LED) architecture enabled by novel large-area parallel processing technologies, reduced number ofmore » fabrication steps, and minimized raw materials use. This new scheme is expected to enable ultra-compact LED components exhibiting simultaneously high efficacy and high color quality. By the end of the program, Cree fabricated warm-white LEDs with a room-temperature “instant on” efficacy of >135 lm/W at ~3500K and 90 CRI (when driven at the DOE baseline current density of 35 A/cm2). Cree modified the conventional LED fabrication process flow in a manner that is expected to translate into simultaneously high throughput and yield for ultra-compact packages. Building on its deep expertise in LED wafer fabrication, Cree developed these ultra-compact LEDs to have no compromises in color quality or efficacy compared to their conventional counterparts. Despite their very small size, the LEDs will also be robustly electrically integrated into luminaire systems with the same attach yield as conventional packages. The versatility of the prototype high-efficacy LED architecture will likely benefit solid-state lighting (SSL) luminaire platforms ranging from bulbs to troffers. We anticipate that the prototype LEDs will particularly benefit luminaires with large numbers of distributed compact packages, such as linear and area luminaires (e.g. troffers). The

  4. Integrated Nanoscale Antenna-LED for On-Chip Optical Communication

    NASA Astrophysics Data System (ADS)

    Fortuna, Seth

    Traditional semiconductor light emitting diodes (LEDs) have low modulation speed because of long spontaneous emission lifetime. Spontaneous emission in semiconductors (and indeed most light emitters) is an inherently slow process owing to the size mismatch between the dipole length of the optical dipole oscillators responsible for light emission and the wavelength of the emitted light. More simply stated: semiconductors behave as a poor antenna for its own light emission. By coupling a semiconductor at the nanoscale to an external antenna, the spontaneous emission rate can be dramatically increased alluding to the exciting possibility of an antenna-LED that can be directly modulated faster than the laser. Such an antenna-LED is well-suited as a light source for on-chip optical communication where small size, fast speed, and high efficiency are needed to achieve the promised benefit of reduced power consumption of on-chip optical interconnect links compared with less efficient electrical interconnect links. Despite the promise of the antenna-LED, significant challenges remain to implement an antenna-coupled device in a monolithically integrated manner. Notably, most demonstrations of antenna-enhanced spontaneous emission have relied upon optical pumping of the light emitting material which is useful for fundamental studies; however, an electrical injection scheme is required for practical implementation of an antenna-LED. In this dissertation, demonstration of an electrically-injected III-V antenna-LED is reported: an important milestone toward on-chip optical interconnects. In the first part of this dissertation, the general design principles of enhancing the spontaneous emission rate of a semiconductor with an optical antenna is discussed. The cavity-backed slot antenna is shown to be uniquely suited for an electrically-injected antenna-LED because of large spontaneous emission enhancement, simple fabrication, and directional emission of light. The design

  5. Toward blue emission in ZnO based LED

    NASA Astrophysics Data System (ADS)

    Viana, Bruno; Pauporté, Thierry; Lupan, Oleg; Le Bahers, Tangui; Ciofini, Ilaria

    2012-03-01

    The bandgap engineering of ZnO nanowires by doping is of great importance for tunable light emitting diode (LED) applications. We present a combined experimental and computational study of ZnO doping with Cd or Cu atoms in the nanomaterial. Zn1-xTMxO (TM=Cu, Cd) nanowires have been epitaxially grown on magnesium-doped p-GaN by electrochemical deposition. The Zn1-xTMxO/p-GaN heterojunction was integrated in a LED structure. Nanowires act as the light emitters and waveguides. At room temperature, TM-doped ZnO based LEDs exhibit low-threshold emission voltage and electroluminescence emission shifted from ultraviolet to violet-blue spectral region compared to pure ZnO LEDs. The emission wavelength can be tuned by changing the transition metal (TM) content in the ZnO nanomaterial and the shift is discussed, including insights from DFT computational investigations.

  6. Chip-scale thermal management of high-brightness LED packages

    NASA Astrophysics Data System (ADS)

    Arik, Mehmet; Weaver, Stanton

    2004-10-01

    The efficiency and reliability of the solid-state lighting devices strongly depend on successful thermal management. Light emitting diodes, LEDs, are a strong candidate for the next generation, general illumination applications. LEDs are making great strides in terms of lumen performance and reliability, however the barrier to widespread use in general illumination still remains the cost or $/Lumen. LED packaging designers are pushing the LED performance to its limits. This is resulting in increased drive currents, and thus the need for lower thermal resistance packaging designs. As the power density continues to rise, the integrity of the package electrical and thermal interconnect becomes extremely important. Experimental results with high brightness LED packages show that chip attachment defects can cause significant thermal gradients across the LED chips leading to premature failures. A numerical study was also carried out with parametric models to understand the chip active layer temperature profile variation due to the bump defects. Finite element techniques were utilized to evaluate the effects of localized hot spots at the chip active layer. The importance of "zero defects" in one of the more popular interconnect schemes; the "epi down" soldered flip chip configuration is investigated and demonstrated.

  7. A synthetic method of solar spectrum based on LED

    NASA Astrophysics Data System (ADS)

    Wang, Ji-qiang; Su, Shi; Zhang, Guo-yu; Zhang, Jian

    2017-10-01

    A synthetic method of solar spectrum which based on the spectral characteristics of the solar spectrum and LED, and the principle of arbitrary spectral synthesis was studied by using 14 kinds of LED with different central wavelengths.The LED and solar spectrum data were selected by Origin Software firstly, then calculated the total number of LED for each center band by the transformation relation between brightness and illumination and Least Squares Curve Fit in Matlab.Finally, the spectrum curve of AM1.5 standard solar spectrum was obtained. The results met the technical indexes of the solar spectrum matching with ±20% and the solar constant with >0.5.

  8. Highly Efficient Small Form Factor LED Retrofit Lamp

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Steven Allen; Fred Palmer; Ming Li

    2011-09-11

    This report summarizes work to develop a high efficiency LED-based MR16 lamp downlight at OSRAM SYLVANIA under US Department of Energy contract DE-EE0000611. A new multichip LED package, electronic driver, and reflector optic were developed for these lamps. At steady-state, the lamp luminous flux was 409 lumens (lm), luminous efficacy of 87 lumens per watt (LPW), CRI (Ra) of 87, and R9 of 85 at a correlated color temperature (CCT) of 3285K. The LED alone achieved 120 lumens per watt efficacy and 600 lumen flux output at 25 C. The driver had 90% electrical conversion efficiency while maintaining excellent powermore » quality with power factor >0.90 at a power of only 5 watts. Compared to similar existing MR16 lamps using LED sources, these lamps had much higher efficacy and color quality. The objective of this work was to demonstrate a LED-based MR16 retrofit lamp for replacement of 35W halogen MR16 lamps having (1) luminous flux of 500 lumens, (2) luminous efficacy of 100 lumens per watt, (3) beam angle less than 40{sup o} and center beam candlepower of at least 1000 candelas, and (4) excellent color quality.« less

  9. Peer-led small groups: Are we on the right track?

    PubMed

    Moore, Fraser

    2017-10-01

    Peer tutor-led small group sessions are a valuable learning strategy but students may lack confidence in the absence of a content expert. This study examined whether faculty reinforcement of peer tutor-led small group content was beneficial. Two peer tutor-led small group sessions were compared with one faculty-led small group session using questionnaires sent to student participants and interviews with the peer tutors. One peer tutor-led session was followed by a lecture with revision of the small group content; after the second, students submitted a group report which was corrected and returned to them with comments. Student participants and peer tutors identified increased discussion and opportunity for personal reflection as major benefits of the peer tutor-led small group sessions, but students did express uncertainty about gaps in their learning following these sessions. Both methods of subsequent faculty reinforcement were perceived as valuable by student participants and peer tutors. Knowing in advance that the group report would be corrected reduced discussion in some groups, potentially negating one of the major benefits of the peer tutor-led sessions. Faculty reinforcement of peer-tutor led small group content benefits students but close attention should be paid to the method of reinforcement.

  10. BiliLED low cost neonatal phototherapy, from prototype to industry

    NASA Astrophysics Data System (ADS)

    Geido, Daniel; Failache, Horacio; Simini, Franco

    2007-11-01

    BiliLED is a phototherapy instrument designed to reduce bilirrubin blood rates in new born babies with jaundice. The light source is centred at 470 nm with a bandwidth of 35 nm and includes a matrix of 196 (14×14) InGaN LEDs. The optical elements are designed to maximize the light intensity useful for treatment, with a small number of LEDs in a compact and low cost unit. The optic array is such that every LED illuminates all the treatment area, which ensures redundancy and, thus, a high reliability not to be found in single-lamp instruments. Thermal dissipation and cost of BiliLED are both an order-of-magnitude smaller than conventional therapy lamps. BiliLED adjusts coetaneous irradiation with a feedback loop to compensate the loss or aging of LEDs achieving a calibrated light source for over a decade of use. A clinical trial in 20 hyperbilirrubinaemia patients shows 16% bilirrubin degradation within 24 hours of treatment, higher than most lamp phototherapy instruments. The steps from prototype to commercial model are described.

  11. Bandwidth correction for LED chromaticity based on Levenberg-Marquardt algorithm

    NASA Astrophysics Data System (ADS)

    Huang, Chan; Jin, Shiqun; Xia, Guo

    2017-10-01

    Light emitting diode (LED) is widely employed in industrial applications and scientific researches. With a spectrometer, the chromaticity of LED can be measured. However, chromaticity shift will occur due to the broadening effects of the spectrometer. In this paper, an approach is put forward to bandwidth correction for LED chromaticity based on Levenberg-Marquardt algorithm. We compare chromaticity of simulated LED spectra by using the proposed method and differential operator method to bandwidth correction. The experimental results show that the proposed approach achieves an excellent performance in bandwidth correction which proves the effectiveness of the approach. The method has also been tested on true blue LED spectra.

  12. DEVELOPMENT, DESIGN AND CONSUMER TESTING OF MARKETABLE RESIDENTIAL LED LIGHT LUMINAIRES

    EPA Science Inventory

    Developing marketable LED luminaires poses challenges, even though LEDs are energy-efficient and an ecological alternative to conventionally lighting. Challenges include: perceptions that the color rendition of LEDs is unacceptable to the public; numbers of LEDs must be grou...

  13. Nurse-led diabetes management in remote locations.

    PubMed

    Kirby, Sue; Moore, Malcolm; McCarron, Trish; Perkins, David; Lyle, David

    2015-01-01

    Nurse-led diabetes management has been shown to be effective in urban and regional general practice. We sought to test the feasibility of providing a nurse-led annual cycle of diabetes care in a remote location and to explore the factors that patients indicated were important in diabetes self-management. We conducted a pilot study in 3 locations: 1 town and 2 small townships in remote Australia. A chronic disease nurse (CDN) visited each patient over the course of a year. We examined patient clinical outcomes and interview data. We estimated the cost per hour of the CDN's time, including travel time, per 1% drop in glycated hemoglobin (HbA1C). A total of 21 patients participated in the pilot study. Clinical findings showed significant reductions in HbA1C levels after the nurse-led intervention. Patients reported that they trusted the nurse and thought her advice was pitched at their level. Patients were motivated through a process that included emotional response, change identity and acceptance. The estimated cost in CDN hours per 1% drop in HbA1C level was A$242.95 (Can$237.60). Nurse-led diabetes care motivated patients to manage their diabetes and resulted in a significant improvement in diabetes management in this remote setting.

  14. Meeting the challenges of developing LED-based projection displays

    NASA Astrophysics Data System (ADS)

    Geißler, Enrico

    2006-04-01

    The main challenge in developing a LED-based projection system is to meet the brightness requirements of the market. Therefore a balanced combination of optical, electrical and thermal parameters must be reached to achieve these performance and cost targets. This paper describes the system design methodology for a digital micromirror display (DMD) based optical engine using LEDs as the light source, starting at the basic physical and geometrical parameters of the DMD and other optical elements through characterization of the LEDs to optimizing the system performance by determining optimal driving conditions. LEDs have a luminous flux density which is just at the threshold of acceptance in projection systems and thus only a fully optimized optical system with a matched set of LEDs can be used. This work resulted in two projection engines, one for a compact pocket projector and the other for a rear projection television, both of which are currently in commercialization.

  15. Thermal management methods for compact high power LED arrays

    NASA Astrophysics Data System (ADS)

    Christensen, Adam; Ha, Minseok; Graham, Samuel

    2007-09-01

    The package and system level temperature distributions of a high power (>1W) light emitting diode (LED) array has been investigated using numerical heat flow models. For this analysis, a thermal resistor network model was combined with a 3D finite element submodel of an LED structure to predict system and die level temperatures. The impact of LED array density, LED power density, and active versus passive cooling methods on device operation were calculated. In order to help understand the role of various thermal resistances in cooling such compact arrays, the thermal resistance network was analyzed in order to estimate the contributions from materials as well as active and passive cooling schemes. An analysis of thermal stresses and residual stresses in the die are also calculated based on power dissipation and convection heat transfer coefficients. Results show that the thermal stress in the GaN layer are compressive which can impact the band gap and performance of the LEDs.

  16. LED-based UV source for monitoring spectroradiometer properties

    NASA Astrophysics Data System (ADS)

    Sildoja, Meelis-Mait; Nevas, Saulius; Kouremeti, Natalia; Gröbner, Julian; Pape, Sven; Pendsa, Stefan; Sperfeld, Peter; Kemus, Fabian

    2018-06-01

    A compact and stable UV monitoring source based on state-of-the-art commercially available ultraviolet light emitting diodes (UV-LEDs) has been developed. It is designed to trace the radiometric stability—both responsivity and wavelength scale—of array spectroradiometers measuring direct solar irradiance in the wavelength range between 300 nm and 400 nm. The spectral irradiance stability of the UV-LED-based light source observed in the laboratory after seasoning (burning-in) the individual LEDs was better than 0.3% over a 12 h period of continuous operation. The integral irradiance measurements of the source over a period of several months, where the UV-LED source was not operated continuously between the measurements, showed stability within 0.3%. In-field measurements of the source with an array spectroradiometer indicated the stability of the source to be within the standard uncertainty of the spectroradiometer calibration, which was within 1% to 2%.

  17. Color adjustable LED driver design based on PWM

    NASA Astrophysics Data System (ADS)

    Du, Yiying; Yu, Caideng; Que, Longcheng; Zhou, Yun; Lv, Jian

    2012-10-01

    Light-emitting diode (LED) is a liquid cold source light source that rapidly develops in recent years. The merits of high brightness efficiency, long duration, high credibility and no pollution make it satisfy our demands for consumption and natural life, and gradually replace the traditional lamp-house-incandescent light and fluorescent light. However, because of the high cost and unstable drive circuit, the application range is restricted. To popularize the applications of the LED, we focus on improving the LED driver circuit to change this phenomenon. Basing on the traditional LED drive circuit, we adopt pre-setup constant current model and introduce pulse width modulation (PWM) control method to realize adjustable 256 level-grays display. In this paper, basing on human visual characteristics and the traditional PWM control method, we propose a new PWM control timing clock to alter the duty cycle of PWM signal to realize the simple gamma correction. Consequently, the brightness can accord with our visual characteristics.

  18. Integrated LED-based luminaire for general lighting

    DOEpatents

    Dowling, Kevin J.; Lys, Ihor A.; Williamson, Ryan C.; Roberge, Brian; Roberts, Ron; Morgan, Frederick; Datta, Michael Jay; Mollnow, Tomas Jonathan

    2016-08-30

    Lighting apparatus and methods employing LED light sources are described. The LED light sources are integrated with other components in the form of a luminaire or other general purpose lighting structure. Some of the lighting structures are formed as Parabolic Aluminum Reflector (PAR) luminaires, allowing them to be inserted into conventional sockets. The lighting structures display beneficial operating characteristics, such as efficient operation, high thermal dissipation, high output, and good color mixing.

  19. Integrated LED-based luminare for general lighting

    DOEpatents

    Dowling, Kevin J.; Lys, Ihor A.; Roberge, Brian; Williamson, Ryan C.; Roberts, Ron; Datta, Michael; Mollnow, Tomas; Morgan, Frederick M.

    2013-03-05

    Lighting apparatus and methods employing LED light sources are described. The LED light sources are integrated with other components in the form of a luminaire or other general purpose lighting structure. Some of the lighting structures are formed as Parabolic Aluminum Reflector (PAR) luminaires, allowing them to be inserted into conventional sockets. The lighting structures display beneficial operating characteristics, such as efficient operation, high thermal dissipation, high output, and good color mixing.

  20. Characterization of an LED based photoreactor to degrade 4-chlorophenol in an aqueous medium using coumarin (C-343) sensitized TiO2.

    PubMed

    Ghosh, Jyoti P; Langford, Cooper H; Achari, Gopal

    2008-10-16

    A detailed performance evaluation of a simple high intensity LED based photoreactor exploiting a narrow wavelength range of the LED to match the spectrum of a dye in a photocatalysis system is reported. A dye sensitized (coumarin-343, lambda max = 446 nm) TiO 2 photocatalyst was used for the degradation of 4-chlorophenol (4-CP) in an aqueous medium using the 436 nm LED based photoreactor. The LED reactor performed competitively with a conventional multilamp reactor and sunlight in the degradation of 4-CP. Light intensities entering the reaction vessel were measured by conventional ferrioxalate actinometry. The results can be fitted by approximate first order kinetic behavior in this system. Hydroxyl radicals were detected by spin trapping EPR, and effects of OH radical quenchers on kinetics suggest that the reaction is initiated by these radicals or their equivalents. LEDs operating at competitive intensities offer a number of advantages to the photochemist or the environmental engineer via long life, efficient current to light conversion, narrow bandwidth, forward directed output, and direct current power for remote operation. Matching light source spectrum to chromophore is a key.

  1. Smart LED lighting for major reductions in power and energy use for plant lighting in space

    NASA Astrophysics Data System (ADS)

    Poulet, Lucie

    Launching or resupplying food, oxygen, and water into space for long-duration, crewed missions to distant destinations, such as Mars, is currently impossible. Bioregenerative life-support systems under development worldwide involving photoautotrophic organisms offer a solution to the food dilemma. However, using traditional Earth-based lighting methods, growth of food crops consumes copious energy, and since sunlight will not always be available at different space destinations, efficient electric lighting solutions are badly needed to reduce the Equivalent System Mass (ESM) of life-support infrastructure to be launched and transported to future space destinations with sustainable human habitats. The scope of the present study was to demonstrate that using LEDs coupled to plant detection, and optimizing spectral and irradiance parameters of LED light, the model crop lettuce (Lactuca sativa L. cv. Waldmann's Green) can be grown with significantly lower electrical energy for plant lighting than using traditional lighting sources. Initial experiments aimed at adapting and troubleshooting a first-generation "smart" plant-detection system coupled to LED arrays resulted in optimizing the detection process for plant position and size to the limits of its current design. Lettuce crops were grown hydroponically in a growth chamber, where temperature, relative humidity, and CO2 level are controlled. Optimal irradiance and red/blue ratio of LED lighting were determined for plant growth during both lag and exponential phases of crop growth. Under optimizing conditions, the efficiency of the automatic detection system was integrated with LED switching and compared to a system in which all LEDs were energized throughout a crop-production cycle. At the end of each cropping cycle, plant fresh and dry weights and leaf area were measured and correlated with the amount of electrical energy (kWh) consumed. Preliminary results indicated that lettuce plants grown under

  2. Stakeholder Values and Perspectives when Implementing Led Lights on Navy Ships

    DTIC Science & Technology

    2014-06-01

    Additionally, the M1 IntelliTube is a retrofit lamp , 32 which works with line power or any of the legacy ballasts.” ( LED /IntelliTube NAVSEA: LED ...only factor taken into consideration, then break-even point for LED lighting, Navy- wide, is approximately one hour to change the lamp . Of note...Energy Focus. (2013, July 3). Energy Focus: Specifications: IntelliTube LED replacement lamp , 24”, T12 LED lamp . Retrieved from http

  3. Uniformity of LED light illumination in application to direct imaging lithography

    NASA Astrophysics Data System (ADS)

    Huang, Ting-Ming; Chang, Shenq-Tsong; Tsay, Ho-Lin; Hsu, Ming-Ying; Chen, Fong-Zhi

    2016-09-01

    Direct imaging has widely applied in lithography for a long time because of its simplicity and easy-maintenance. Although this method has limitation of lithography resolution, it is still adopted in industries. Uniformity of UV irradiance for a designed area is an important requirement. While mercury lamps were used as the light source in the early stage, LEDs have drawn a lot of attention for consideration from several aspects. Although LED has better and better performance, arrays of LEDs are required to obtain desired irradiance because of limitation of brightness for a single LED. Several effects are considered that affect the uniformity of UV irradiance such as alignment of optics, temperature of each LED, performance of each LED due to production uniformity, and pointing of LED module. Effects of these factors are considered to study the uniformity of LED Light Illumination. Numerical analysis is performed by assuming a serious of control factors to have a better understanding of each factor.

  4. A Novel Methodology for Measurements of an LED's Heat Dissipation Factor

    NASA Astrophysics Data System (ADS)

    Jou, R.-Y.; Haung, J.-H.

    2015-12-01

    Heat generation is an inevitable byproduct with high-power light-emitting diode (LED) lighting. The increase in junction temperature that accompanies the heat generation sharply degrades the optical output of the LED and has a significant negative influence on the reliability and durability of the LED. For these reasons, the heat dissipation factor, Kh, is an important factor in modeling and thermal design of LED installations. In this study, a methodology is proposed and experiments are conducted to determine LED heat dissipation factors. Experiments are conducted for two different brands of LED. The average heat dissipation factor of the Edixeon LED is 0.69, and is 0.60 for the OSRAM LED. By using the developed test method and comparing the results to the calculated luminous fluxes using theoretical equations, the interdependence of optical, electrical, and thermal powers can be predicted with a reasonable accuracy. The difference between the theoretical and experimental values is less than 9 %.

  5. Skin photorejuvenation effects of light-emitting diodes (LEDs): a comparative study of yellow and red LEDs in vitro and in vivo.

    PubMed

    Kim, S K; You, H R; Kim, S H; Yun, S J; Lee, S C; Lee, J B

    2016-10-01

    Red-coloured light-emitting diodes (LEDs) can improve skin photorejuvenation and regeneration by increasing cellular metabolic activity. To evaluate the effectiveness of visible LEDs with specific wavelengths for skin photorejuvenation in vitro and in vivo. Normal human dermal fibroblasts (HDFs) from neonatal foreskin were cultured and irradiated in vitro by LEDs at different wavelengths (410-850 nm) and doses (0-10 J/cm(2) ). In vivo experiments were performed on the skin of hairless mice. Expression of collagen (COL) and matrix metalloproteinases (MMPs) was evaluated by semi-quantitative reverse transcription PCR (semi-qRT-PCR), western blotting and a procollagen type I C-peptide enzyme immunoassay (EIA). Haematoxylin and eosin and Masson trichrome stains were performed to evaluate histological changes. In HDFs, COL I was upregulated and MMP-1 was downregulated in response to LED irradiation at 595 ± 2 and 630 ± 8 nm. In the EIA, a peak result was achieved at a dose of 5 J/cm(2) with LED at 595 ± 2 nm. In vivo, COL I synthesis was upregulated in a dose-dependent manner to both 595 and 630 nm LED irradiation, and this effect was prolonged to 21 days after a single irradiation with a dose of 100 J/cm(2) . These histological changes were consistent with the results of semi-qRT-PCR and western blots. Specific LED treatment with 595 ± 2 and 630 ± 8 nm irradiation was able to modulate COL and MMPs in skin, with the effects persisting for at least 21 days after irradiation. These findings suggest that yellow and red LEDs might be useful tools for skin photorejuvenation. © 2016 British Association of Dermatologists.

  6. Pharmacist-led Chronic Disease Management: A Systematic Review of Effectiveness and Harms Compared With Usual Care.

    PubMed

    Greer, Nancy; Bolduc, Jennifer; Geurkink, Eric; Rector, Thomas; Olson, Kimberly; Koeller, Eva; MacDonald, Roderick; Wilt, Timothy J

    2016-04-26

    Increased involvement of pharmacists in patient care may increase access to health care and improve patient outcomes. To determine the effectiveness and harms of pharmacist-led chronic disease management for community-dwelling adults. MEDLINE, Cochrane Library, CINAHL, and International Pharmaceutical Abstracts from 1995 through February 2016, and reference lists of systematic reviews and included studies. 65 patient populations in 63 studies conducted in the United States and of any design reported outcomes of pharmacist-led chronic disease management versus a comparator for community-dwelling adults in the United States. Studies set in retail pharmacies were excluded. Data extraction done by a single investigator was confirmed by a second investigator; risk of bias was assessed by 2 investigators; and strength of evidence was determined by consensus. Pharmacist-led care was associated with similar numbers of office visits, urgent care or emergency department visits, and hospitalizations (moderate-strength evidence) and medication adherence (low-strength evidence) compared with usual care (typically continuing a prestudy visit schedule). Pharmacist-led care increased the number or dose of medications received and improved study-selected glycemic, blood pressure, and lipid goal attainment (moderate-strength evidence). Mortality and clinical events were similar (low-strength evidence). Evidence on patient satisfaction was mixed and insufficient. The reporting of harms was limited. Interventions were heterogeneous. Studies were typically short-term and designed to assess physiologic intermediate outcomes rather than clinical events. Reporting of many clinical outcomes of interest was limited, and often they were not the study-defined primary end points. Pharmacist-led chronic disease management was associated with effects similar to those of usual care for resource utilization and may improve physiologic goal attainment. Further research is needed to determine

  7. Vision communications based on LED array and imaging sensor

    NASA Astrophysics Data System (ADS)

    Yoo, Jong-Ho; Jung, Sung-Yoon

    2012-11-01

    In this paper, we propose a brand new communication concept, called as "vision communication" based on LED array and image sensor. This system consists of LED array as a transmitter and digital device which include image sensor such as CCD and CMOS as receiver. In order to transmit data, the proposed communication scheme simultaneously uses the digital image processing and optical wireless communication scheme. Therefore, the cognitive communication scheme is possible with the help of recognition techniques used in vision system. By increasing data rate, our scheme can use LED array consisting of several multi-spectral LEDs. Because arranged each LED can emit multi-spectral optical signal such as visible, infrared and ultraviolet light, the increase of data rate is possible similar to WDM and MIMO skills used in traditional optical and wireless communications. In addition, this multi-spectral capability also makes it possible to avoid the optical noises in communication environment. In our vision communication scheme, the data packet is composed of Sync. data and information data. Sync. data is used to detect the transmitter area and calibrate the distorted image snapshots obtained by image sensor. By making the optical rate of LED array be same with the frame rate (frames per second) of image sensor, we can decode the information data included in each image snapshot based on image processing and optical wireless communication techniques. Through experiment based on practical test bed system, we confirm the feasibility of the proposed vision communications based on LED array and image sensor.

  8. Energy-Saving Tunnel Illumination System Based on LED's Intelligent Control

    NASA Astrophysics Data System (ADS)

    Guo, Shanshan; Gu, Hanting; Wu, Lan; Jiang, Shuixiu

    2011-02-01

    At present there is a lot of electric energy wastage in tunnel illumination, whose design is based on the maximum brightness outside and the maximum vehicle speed all year round. LED's energy consumption is low, and the control of its brightness is simple and effective. It can be quickly adjusted between 0-100% of its maximum brightness, and will not affect the service life. Therefore, using LED as tunnel's illumination source, we can achieve a good energy saving effect. According to real-time data acquisition of vehicle speed, traffic flow and brightness outside the tunnel, the auto real-time control of tunnel illumination can be achieved. And the system regulated the LED luminance by means of combination of LED power module and intelligent control module. The tunnel information was detected by inspection equipments, which included luminometer, vehicle detector, and received by RTU(Remote Terminal Unit), then synchronously transmitted to PC. After data processing, RTU emitted the dimming signal to the LED driver to adjust the brightness of LED. Despite the relatively high cost of high-power LED lights, the enormous energy-saving effect and the well-behaved controllability is beyond compare to other lighting devices.

  9. Dome diagnostics system of optical parameters and characteristics of LEDs

    NASA Astrophysics Data System (ADS)

    Peretyagin, Vladimir S.; Pavlenko, Nikita A.

    2017-09-01

    Scientific and technological progress of recent years in the production of the light emitting diodes (LEDs) has led to the expansion of areas of their application from the simplest systems to high precision lighting devices used in various fields of human activity. However, development and production (especially mass production) of LED lighting devices are impossible without a thorough analysis of its parameters and characteristics. There are many ways and devices for analysis the spatial, energy and colorimetric parameters of LEDs. The most methods are intended for definition only one parameter (for example, luminous flux) or one characteristic (for example, the angular distribution of energy or the spectral characteristics). Besides, devices used these methods are intended for measuring parameters in only one point or plane. This problem can be solved by using a dome diagnostics system of optical parameters and characteristics of LEDs, developed by specialists of the department OEDS chair of ITMO University in Russia. The paper presents the theoretical aspects of the analysis of LED's spatial (angular), energy and color parameters by using mentioned of diagnostics system. The article also presents the results of spatial), energy and color parameters measurements of some LEDs brands.

  10. Effects of LED or laser phototherapy on bone defects grafted with MTA and irradiated with laser or LED light: a comparative Raman spectroscopic study

    NASA Astrophysics Data System (ADS)

    Pinheiro, Antonio L. B.; Soares, Luiz G. P.; Barbosa, Artur Felipe S.; Silveira, Landulfo, Jr.

    2012-03-01

    We studied peaks of calcium hydroxyapatite - CHA on defects grafted with MTA, treated or not with Light Emitting Diode - LED or IR Laser. 54 rats were divided in 6 groups each subdivided into 3 subgroups (15,21,30d). LED (λ850 +/- 10nm) or IR Laser (λ850 nm) was applied over (LED) or in 4 points around the defect at 48 h intervals for 15 days. Raman readings were taken at the surface of the defect. The smaller overall intensity of the peak was found in Group MTA + Laser (1510.2 +/- 274.1) and the highest on Group LED (2322 +/- 715). There were no statistically significant differences between non-irradiated subjects on regards the CHA peaks. On the other hand, there were statistically significant differences between the Group Clot and LED, Clot and Laser, and Clot and MTA + Laser (p =0.01, p = 0.02, p = 0.003). There were no significant differences between Group MTA and MTA + LED (p=0.2) but significant differences were seen between Groups MTA and MTA + Laser (p=0.01). Significant differences were also observed between Groups LED and Laser (p <0.001) and between Groups MTA + LED and MTA + Laser (p=0.009). MTA, due to its characteristics, seemed to be directly affected by the light. However, the use of either phototherapy positively affected bone healing similarly as observed on different studies using other biomaterials. The overall analysis of our results indicated that the use of either light source resulted in a better, more advanced, and of quality bone repair.

  11. LED instrument approach instruction display

    NASA Technical Reports Server (NTRS)

    Meredith, B. D.; Kelly, W. L., IV; Crouch, R. K.

    1979-01-01

    A display employing light emitting diodes (LED's) was developed to demonstrate the feasibility of such displays for presenting landing and navigation information to reduce the workload of general aviation pilots during IFR flight. The display consists of a paper tape reader, digital memory, control electronics, digital latches, and LED alphanumeric displays. A presentable digital countdown clock-timer is included as part of the system to provide a convenient means of monitoring time intervals for precise flight navigation. The system is a limited capability prototype assembled to test pilot reaction to such a device under simulated IFR operation. Pilot opinion indicates that the display is helpful in reducing the IFR pilots workload when used with a runway approach plate. However, the development of a compact, low power second generation display was recommended which could present several instructions simultaneously and provide information update capability. A microprocessor-based display could fulfill these requirements.

  12. Assessing the Performance of LED-Based Flashlights Available in the Kenyan Off-Grid Lighting Market

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tracy, Jennifer; Jacobson, Arne; Mills, Evan

    Low cost rechargeable flashlights that use LED technology are increasingly available in African markets. While LED technology holds promise to provide affordable, high quality lighting services, the widespread dissemination of low quality products may make it difficult to realize this potential. This study includes performance results for three brands of commonly available LED flashlights that were purchased in Kenya in 2009. The performance of the flashlights was evaluated by testing five units for each of the three brands. The tests included measurements of battery capacity, time required to charge the battery, maximum illuminance at one meter, operation time and lux-hoursmore » from a fully charged battery, light distribution, and color rendering. All flashlights tested performed well below the manufacturers? rated specifications; the measured battery capacity was 30-50percent lower than the rated capacity and the time required to fully charge the battery was 6-25percent greater than the rated time requirement. Our analysis further shows that within each brand there is considerable variability in each performance indicator. The five samples within a single brand varied from each other by as much as 22percent for battery capacity measurements, 3.6percent for the number of hours required for a full charge, 23percent for maximum initial lux, 38percent for run time, 11percent for light distribution and by as much as 200percent for color rendering. Results obtained are useful for creating a framework for quality assurance of off-grid LED products and will be valuable for informing consumers, distributors and product manufacturers about product performance.« less

  13. Photomatrix LED therapy of extensive cutaneous pathology

    NASA Astrophysics Data System (ADS)

    Zharov, Vladimir P.; Menyaev, Yulian A.; Zharova, I. Z.; Leviev, Dmitry O.; Tsarev, V. N.; Sarantsev, V. P.; Krusic, Joze

    2000-05-01

    Standard sources of radiation have not sufficient efficiency at treating spatially extended pathology, especially when pathologic areas involve opposite sides of the human being's body or when they are uneven in shape. The typical examples of such pathology are extensive burns, oedema, inflammatory processes, infectious wounds, actinic keratosis, psoriasis, arthritis and neurological diseases. Superbright LEDs gathered in a matrix and grasping the area of irradiation are the most suitable sources of radiation. This article presents the result of investigation of the effectiveness of various types of the blue-to-infrared spectrum range LED array that allow irradiating a surface with an area from several cm2 to several thousand cm2 including the whole human being's body with the intensity varying from 1 to 100 mW/cm2. Besides the matrixes, composed of separate light diodes, modular systems with separate monolithic hybrid chips with a high density of positioning the sources of radiation are considered. The peculiarities and results of applying such systems to treat oedema, cancer, weight regulation, neurological diseases, different infections diseases in combination with PDT, stomatitis and paradontosis are analyzed. The parameters of the photomatrix LED for different spectral regions and different geometry from flat shape to semispherical and cylindrical are presented. The perspective combination photomatrix LED with another therapeutical devices including photovacuum and photomagnetic therapy are considered.

  14. Rethinking the Regular Education Initiative: Focus on the Classroom Teacher.

    ERIC Educational Resources Information Center

    Gersten, Russell, Woodward, John

    1990-01-01

    The first section of this essay reviews forces that led to the Regular Education Initiative (REI). Findings from research on effective instruction, innovation and staff development are synthesized. A conceptual framework is offered to explain factors necessary to create meaningful, sustained changes in classroom practices as required by the REI.…

  15. Developing Cooperative Learning in Initial Teacher Education: Indicators for Implementation

    ERIC Educational Resources Information Center

    Jolliffe, Wendy; Snaith, Jessica

    2017-01-01

    This paper examines the impact of supporting pre-service teachers to use cooperative learning in one initial teacher education institution in England. In a context where the government requires all teacher education to be "school-led" and where school partners do not commonly use cooperative learning (Baines, Rubie-Davies, and Blatchford…

  16. Aerial LED signage by use of crossed-mirror array

    NASA Astrophysics Data System (ADS)

    Yamamoto, Hirotsugu; Kujime, Ryousuke; Bando, Hiroki; Suyama, Shiro

    2013-03-01

    3D representation of digital signage improves its significance and rapid notification of important points. Real 3D display techniques such as volumetric 3D displays are effective for use of 3D for public signs because it provides not only binocular disparity but also motion parallax and other cues, which will give 3D impression even people with abnormal binocular vision. Our goal is to realize aerial 3D LED signs. We have specially designed and fabricated a reflective optical device to form an aerial image of LEDs with a wide field angle. The developed reflective optical device composed of crossed-mirror array (CMA). CMA contains dihedral corner reflectors at each aperture. After double reflection, light rays emitted from an LED will converge into the corresponding image point. The depth between LED lamps is represented in the same depth in the floating 3D image. Floating image of LEDs was formed in wide range of incident angle with a peak reflectance at 35 deg. The image size of focused beam (point spread function) agreed to the apparent aperture size.

  17. Issues and solutions: opportunities for European LED manufacturers

    NASA Astrophysics Data System (ADS)

    Pearsall, T. P.

    2007-09-01

    Marketing studies by EPIC show significant revenue opportunities by 2012 for UHB-LEDs in the automotive, LCD backlighting, and architectural lighting sectors. The goal of this workshop on manufacturing issues is to consider five key issues for UHB-LED manufacturing and to propose solutions that will pave the way to full exploitation of the opportunities.

  18. Solution of multi-element LED light sources development automation problem

    NASA Astrophysics Data System (ADS)

    Chertov, Aleksandr N.; Gorbunova, Elena V.; Korotaev, Valery V.; Peretyagin, Vladimir S.

    2014-09-01

    The intensive development of LED technologies resulted in the creation of multicomponent light sources in the form of controlled illumination devices based on usage of mentioned LED technologies. These light sources are used in different areas of production (for example, in the food industry for sorting products or in the textile industry for quality control, etc.). The use of LED lighting products in the devices used in specialized lighting, became possible due to wide range of colors of light, LED structures (which determines the direction of radiation, the spatial distribution and intensity of the radiation, electrical, heat, power and other characteristics), and of course, the possibility of obtaining any shade in a wide dynamic range of brightness values. LED-based lighting devices are notable for the diversity of parameters and characteristics, such as color radiation, location and number of emitters, etc. Although LED technologies have several advantages, however, they require more attention if you need to ensure a certain character of illumination distribution and/or distribution of the color picture at a predetermined distance (for example, at flat surface, work zone, area of analysis or observation). This paper presents software designed for the development of the multicomponent LED light sources. The possibility of obtaining the desired color and energy distribution at the zone of analysis by specifying the spatial parameters of the created multicomponent light source and using of real power, spectral and color parameters and characteristics of the LEDs is shown as well.

  19. An LED solar simulator for student labs

    NASA Astrophysics Data System (ADS)

    González, Manuel I.

    2017-05-01

    Measuring voltage-current and voltage-power curves of a photovoltaic module is a nice experiment for high school and undergraduate students. In labs where real sunlight is not available this experiment requires a solar simulator. A prototype of a simulator using LED lamps has been manufactured and tested, and a comparison with classical halogen simulators has been performed. It is found that LED light offers lower levels of irradiance, but much better performance in terms of module output for a given irradiance.

  20. Carrier lifetimes in polar InGaN-based LEDs

    NASA Astrophysics Data System (ADS)

    Wang, Lai; Jin, Jie; Hao, Zhibiao; Luo, Yi

    2018-02-01

    Measurement of carrier lifetime is very important to understand the physics in light-emitting diodes (LEDs), as it builds a link between carrier concentration and excitation power or current density. In this paper, we present our study on optical and electrical characterizations on carrier lifetimes in polar InGaN-based LEDs. First, a carrier rate equation model is proposed to explain the non-exponential nature of time-resolved photoluminescence (TRPL) decay curves, wherein exciton recombination is replaced by bimolecular recombination, considering the influence of polarization field on electron-hole pairs. Then, nonradiative recombination and radiative recombination coefficients can be deduced from fitting and used to calculate the radiative recombination efficiency. By comparing with the temperature-dependent photoluminescence (TDPL) and power-dependent photoluminescence (PDPL), it is found these three methods provide the consistent results. Second, differential carrier lifetimes depending on injection current are measured in commercial near-ultraviolet (NUV), blue and green LEDs. It is found that carrier lifetime is longer in green one and shorter in NUV one, which is attributed to the influence of polarization-induced quantum confined Stark effect (QCSE). This result implies the carrier density is higher in green LED while lower NUV LED, even the injection current is the same. By ignoring Auger recombination and fitting the efficiency-current and carrier lifetime-current curves simultaneously, the dependence of injection efficiency on carrier concentration in different LED samples are plotted. The NUV LED, which has the shallowest InGaN quantum well, actually exhibits the most serious efficiency droop versus carrier concentration. Then, the approaches to overcome the efficiency droop are discussed.

  1. Warm white LEDs lighting over Ra=95 and its applications

    NASA Astrophysics Data System (ADS)

    Kobashi, Katsuya; Taguchi, Tsunemasa

    2007-02-01

    We have for the first time developed warm white LEDs lighting using a combination of near ultraviolet LED and three-band (red, green and blue) white phosphors. This LED has the average color-rendering index Ra=96. Moreover, special color-rendering index R9 (red) and R15 (face color of Japanese) are estimated to be 95 and 97, respectively. We will describe the results of evaluation on the medical lighting applications such as operation, treatment and endoscope experiments, application to the LED fashions and application to the Japanese antique art (ink painting) lighting.

  2. Smart LED allocation scheme for efficient multiuser visible light communication networks.

    PubMed

    Sewaiwar, Atul; Tiwari, Samrat Vikramaditya; Chung, Yeon Ho

    2015-05-18

    In a multiuser bidirectional visible light communication (VLC), a large number of LEDs or an LED array needs to be allocated in an efficient manner to ensure sustainable data rate and link quality. Moreover, in order to support an increasing or decreasing number of users in the network, the LED allocation is required to be performed dynamically. In this paper, a novel smart LED allocation scheme for efficient multiuser VLC networks is presented. The proposed scheme allocates RGB LEDs to multiple users in a dynamic and efficient fashion, while satisfying illumination requirements in an indoor environment. The smart LED array comprised of RGB LEDs is divided into sectors according to the location of the users. The allocated sectors then provide optical power concentration toward the users for efficient and reliable data transmission. An algorithm for the dynamic allocation of the LEDs is also presented. To verify its effective resource allocation feature of the proposed scheme, simulations were performed. It is found that the proposed smart LED allocation scheme provides the effect of optical beamforming toward individual users, thereby increasing the collective power concentration of the optical signals on the desirable users and resulting in significantly increased data rate, while ensuring sufficient illumination in a multiuser VLC environment.

  3. [Study on the safety of blue light leak of LED].

    PubMed

    Shen, Chong-Yu; Xu, Zheng; Zhao, Su-Ling; Huang, Qing-Yu

    2014-02-01

    In this paper, the blue light properties of LED illumination devices have been investigated. Against the status quo of China's LED lighting, we measured the spectrum component of LED lamps and analyzed the photobiological safety under the current domestic and international standards GB/T 20145-2006/CIE S009/E: 2002 and IEC62471: 2006 standards as well as CTL-0744_2009-laser resolution, which provides the reference to the manufacture of LED lighting lamps as well as related safety standards and laws. If the radiance intensity of blue light in LED is lower than 100 W x m(-2) x Sr(-1), there is no harm to human eyes. LEDs will not cause harm to human eyes under normal use, but we should pay attention to the protection of special populations (children), and make sure that they avoid looking at a light source for a long time. The research has found that the blue-rich lamps can affect the human rule of work and rest, and therefore, the LED lamps with color temperature below 4 000 K and color rendering index of 80 are suitable for indoor use. At the same time, the lamps with different parameters should be selected according to the different distances.

  4. Promoting Health Equity Research: Insights from a Canadian Initiative.

    PubMed

    Stewart, Miriam J; Kushner, Kaysi Eastlick

    2014-03-01

    In 2002 the Canadian Institutes of Health Research launched a national initiative to promote health equity research reflecting the World Health Organization imperative of investment in health equity research. Funded researchers and teams have investigated health disparities faced by vulnerable populations, analyzed interactions of health determinants, and tested innovative interventions. Strategies for building research capacity have supported students, postdoctoral fellows, new investigators, and interdisciplinary research teams. Partnerships have been created with 10 national and 7 international organizations. Strategies used to secure and sustain this research initiative could be adapted to other contexts. Nurse scholars led the launch and have sustained the legacy of this national research initiative. Moreover, nurse researchers and research trainees, supported by the initiative, have contributed to the expansion and translation of the health equity knowledge base. Copyright© by Ingram School of Nursing, McGill University.

  5. Choosing surgical lighting in the LED era.

    PubMed

    Knulst, Arjan J; Stassen, Laurents P S; Grimbergen, Cornelis A; Dankelman, Jenny

    2009-12-01

    The aim of this study is to evaluate the illumination characteristics of LED lights objectively to ease the selection of surgical lighting. The illuminance distributions of 5 main and 4 auxiliary lights were measured in 8 clinically relevant scenarios. For each light and scenario, the maximum illuminance E(c) (klux) and the size of the light field d(10) (mm) were computed. The results showed: that large variations for both E(c) (25-160 klux) and d(10) (109-300 mm) existed; that using auxiliary lights reduced both E(c) and d(10) by up to 80% and 30%; that with segmented lights, uneven light distributions occurred; and that with colored LED lights shadow edges on the surgical field became colored. Objective illuminance measurements show a wide variation between lights and a superiority of main over auxiliary lights. Uneven light distributions and colored shadows indicate that LED lights still need to converge to an optimal design.

  6. LED Die-Bonded on the Ag/Cu Substrate by a Sn-BiZn-Sn Bonding System

    NASA Astrophysics Data System (ADS)

    Tang, Y. K.; Hsu, Y. C.; Lin, E. J.; Hu, Y. J.; Liu, C. Y.

    2016-12-01

    In this study, light emitting diode (LED) chips were die-bonded on a Ag/Cu substrate by a Sn-BixZn-Sn bonding system. A high die-bonding strength is successfully achieved by using a Sn-BixZn-Sn ternary system. At the bonding interface, there is observed a Bi-segregation phenomenon. This Bi-segregation phenomenon solves the problems of the brittle layer-type Bi at the joint interface. Our shear test results show that the bonding interface with Bi-segregation enhances the shear strength of the LED die-bonding joints. The Bi-0.3Zn and Bi-0.5Zn die-bonding cases have the best shear strength among all die-bonding systems. In addition, we investigate the atomic depth profile of the deposited Bi-xZn layer by evaporating Bi-xZn E-gun alloy sources. The initial Zn content of the deposited Bi-Zn alloy layers are much higher than the average Zn content in the deposited Bi-Zn layers.

  7. LED phototherapy to prevent mucositis: a case report.

    PubMed

    Lang-Bicudo, Leticia; Eduardo, Fernanda De Paula; Eduardo, Carlos De Paula; Zezell, Denise Maria

    2008-12-01

    The purpose of this case report was to evaluate the efficacy of phototherapy using light-emitting diodes (LEDs) to prevent oral mucositis in a Hodgkin's disease patient treated with the ABVD (doxorubicin [Adriamycin], bleomycin, vinblastine, and dacarbazine) chemotherapy regimen. Mucositis is a common dose-limiting complication of cancer treatment, and if severe it can lead to alterations in treatment planning or suspension of cancer therapy, with serious consequences for tumor response and survival. Therefore, low-power lasers and more recently LEDs, have been used for oral mucositis prevention and management, with good results. In this study, a 34-year-old man received intraoral irradiation with an infrared LED array (880 nm, 3.6 J/cm2, 74 mW) for five consecutive days, starting on chemotherapy day 1. In each chemotherapy cycle, he received the ABVD protocol on days 1 and 15, and received LED treatment for 5 d during each cycle. To analyze the results, the World Health Organization (WHO) scale was used to grade his mucositis, and a visual analogue scale (VAS) was used for pain evaluation, on days 1, 3, 7, 10, and 13 post-chemotherapy. The results showed that the patient did not develop oral mucositis during the five chemotherapy cycles, and he had no pain symptoms. LED therapy was a safe and effective method for preventing oral mucositis in this case report. However, further randomized studies with more patients are needed to prove the efficacy of this method.

  8. LED Street Lighting Solutions: Flagstaff, Arizona as a Case Study

    NASA Astrophysics Data System (ADS)

    Hall, Jeffrey C.

    2018-01-01

    Dark-sky protection in Flagstaff, Arizona extends back to 1958, with the first ordinance in the City banning advertising floodlights. The current ordinance, adopted in 1989, is comprehensive and has played a critical role in maintaining the quality of the night sky for astronomy, tourism, public enjoyment, and other purposes. Flagstaff, like many communities around the world, is now working on a transition from legacy bulb-based technology to LED for its outdoor lighting. The City, Lowell Observatory, the U. S. Naval Observatory, and the Flagstaff Dark Skies Coalition have been working intensively for two years to identify an LED-based street lighting solution that will preserve the City's dark skies while meeting municipal needs. We will soon be installing test fixtures for an innovative solution incorporating narrow-band amber LED and modest amounts of low-CCT white LED. In this talk, I will review the types of LEDs available for outdoor lighting and discuss the plans for Flagstaff's street lighting in the LED era, which we hope will be a model for communities worldwide.

  9. Progress and prospects of GaN-based LEDs using nanostructures

    NASA Astrophysics Data System (ADS)

    Zhao, Li-Xia; Yu, Zhi-Guo; Sun, Bo; Zhu, Shi-Chao; An, Ping-Bo; Yang, Chao; Liu, Lei; Wang, Jun-Xi; Li, Jin-Min

    2015-06-01

    Progress with GaN-based light emitting diodes (LEDs) that incorporate nanostructures is reviewed, especially the recent achievements in our research group. Nano-patterned sapphire substrates have been used to grow an AlN template layer for deep-ultraviolet (DUV) LEDs. One efficient surface nano-texturing technology, hemisphere-cones-hybrid nanostructures, was employed to enhance the extraction efficiency of InGaN flip-chip LEDs. Hexagonal nanopyramid GaN-based LEDs have been fabricated and show electrically driven color modification and phosphor-free white light emission because of the linearly increased quantum well width and indium incorporation from the shell to the core. Based on the nanostructures, we have also fabricated surface plasmon-enhanced nanoporous GaN-based green LEDs using AAO membrane as a mask. Benefitting from the strong lateral SP coupling as well as good electrical protection by a passivation layer, the EL intensity of an SP-enhanced nanoporous LED was significantly enhanced by 380%. Furthermore, nanostructures have been used for the growth of GaN LEDs on amorphous substrates, the fabrication of stretchable LEDs, and for increasing the 3-dB modulation bandwidth for visible light communication. Project supported by the National Natural Science Foundation of China (Grant No. 61334009), the National High Technology Research and Development Program of China (Grant Nos. 2015AA03A101 and 2014BAK02B08), China International Science and Technology Cooperation Program (Grant No. 2014DFG62280), the “Import Outstanding Technical Talent Plan” and “Youth Innovation Promotion Association Program” of the Chinese Academy of Sciences.

  10. High-power UV-LED degradation: Continuous and cycled working condition influence

    NASA Astrophysics Data System (ADS)

    Arques-Orobon, F. J.; Nuñez, N.; Vazquez, M.; Segura-Antunez, C.; González-Posadas, V.

    2015-09-01

    High-power (HP) UV-LEDs can replace UV lamps for real-time fluoro-sensing applications by allowing portable and autonomous systems. However, HP UV-LEDs are not a mature technology, and there are still open issues regarding their performance evolution over time. This paper presents a reliability study of 3 W UV-LEDs, with special focus on LED degradation for two working conditions: continuous and cycled (30 s ON and 30 s OFF). Accelerated life tests are developed to evaluate the influence of temperature and electrical working conditions in high-power LEDs degradation, being the predominant failure mechanism the degradation of the package. An analysis that includes dynamic thermal and optical HP UV-LED measurements has been performed. Static thermal and stress simulation analysis with the finite element method (FEM) identifies the causes of package degradation. Accelerated life test results prove that HP UV-LEDs working in cycled condition have a better performance than those working in continuous condition.

  11. Developing and Implementing Lab Skills Seminars, a Student-Led Learning Approach in the Organic Chemistry Laboratory: Mentoring Current Students While Benefiting Facilitators

    ERIC Educational Resources Information Center

    Sabanayagam, Kalyani; Dani, Vivek D.; John, Matthew; Restivo, Wanda; Mikhaylichenko, Svetlana; Dalili, Shadi

    2017-01-01

    This paper describes the successful adaptation of certain components of peer-led team learning (PLTL) as well as service learning principles into our initiative: lab skills seminars (LSS). These seminars were organized for large, second year organic chemistry laboratory courses. Prior to LSS, the only help available for students was traditional…

  12. Defect analysis of the LED structure deposited on the sapphire substrate

    NASA Astrophysics Data System (ADS)

    Nie, Qichu; Jiang, Zhimin; Gan, Zhiyin; Liu, Sheng; Yan, Han; Fang, Haisheng

    2018-04-01

    Transmission electron microscope (TEM) and double-crystal X-ray diffraction (DCXRD) measurements have been performed to investigate dislocations of the whole structure of the LED layers deposited on both the conventional (unpatterned sapphire substrate, UPSS) and patterned sapphire substrates (PSS). TEM results show that there exists a dislocation-accumulated region near the substrate/GaN interface, where the dislocation density is much higher with the UPPS than that with the PSS. It indicates that the pattern on the substrate surface is able to block the formation and propagation of dislocations. Further analysis discloses that slope of the pattern is found to suppress the deposition of GaN, and thus to provide more spaces for the epitaxially lateral overgrowth (ELO) of high temperature GaN, which significantly reduces the number of the initial islands, and minimizes dislocation formation due to the island coalescence. V-defect incorporating the threading dislocation is detected in the InGaN/GaN multi-quantum wells (MQWs), and its propagation mechanism is determined as the decrease of the surface energy due to the incorporation of indium. In addition, temperature dependence of dislocation formation is further investigated. The results show that dislocation with the screw component decreases monotonously as temperature goes up. However, edge dislocation firstly drops, and then increases by temperature due to the enhanced thermal mismatch stress. It implies that an optimized range of the growth temperature can be obtained to improve quality of the LED layers.

  13. Compact LED based LCOS optical engine for mobile projection

    NASA Astrophysics Data System (ADS)

    Zhang, Wenzi; Li, Xiaoyan; Liu, Qinxiao; Yu, Feihong

    2009-11-01

    With the development of high power LED (light emitting diode) technology and color filter LCOS (liquid crystal on silicon) technology, the research on LED based micro optical engine for mobile projection has been a hot topic recently. In this paper one compact LED powered LCOS optical engine design is presented, which is intended to be embedded in cell phone, digital camera, and so on. Compared to DLP (digital light processor) and traditional color sequential LCOS technology, the color filter based LCOS panel is chosen for the compact optical engine, this is because only white LED is needed. To further decrease the size of the optical engine, only one specifically designed plastic free form lens is applied in the illumination part of the optical engine. This free form lens is designed so that it plays the roles of both condenser and integrator, by which the output light of LED is condensed and redistributed, and light illumination of high efficiency, high uniformity and small incident angle on LCOS is acquired. Besides PBS (polarization beam splitter), LCOS, and projection lens, the compact optical engine contains only this piece of free form plastic lens, which can be produced by plastic injection molding. Finally a white LED powered LCOS optical engine with a compact size of less than 6.6 cc can be acquired. With the ray tracing simulation result, the light efficiency analysis shows that the output flux is over 8.5 ANSI lumens and the ANSI uniformity of over 80%.

  14. Energy efficient LED layout optimization for near-uniform illumination

    NASA Astrophysics Data System (ADS)

    Ali, Ramy E.; Elgala, Hany

    2016-09-01

    In this paper, we consider the problem of designing energy efficient light emitting diodes (LEDs) layout while satisfying the illumination constraints. Towards this objective, we present a simple approach to the illumination design problem based on the concept of the virtual LED. We formulate a constrained optimization problem for minimizing the power consumption while maintaining a near-uniform illumination throughout the room. By solving the resulting constrained linear program, we obtain the number of required LEDs and the optimal output luminous intensities that achieve the desired illumination constraints.

  15. Evaluation of an LED (Light-Emitting Diode) high-mounted signal lamp

    NASA Astrophysics Data System (ADS)

    Olson, P. L.

    1987-02-01

    Two studies are described evaluating high-mounted stoplights using light-emitting diodes (LEDs) compared with conventional incandescent units. The first of these studies obtained ratings from subjects who drove one car and followed another car that was equipped with the test lamps. The results indicate that the subjects generally preferred the LEDs to the conventional lamp. The second study was a laboratory evaluation of the attention-getting capabilities of LED and incandescent stoplights. Under all conditions tested subjects responded faster to the LED units. The response time advantage for the LED units increased with more difficult viewing conditions, such as high levels of illumination and long viewing distance. The results of these investigations are discussed in terms of the applicability of the LED technology to high mounted stoplights on motor vehicles.

  16. Optical design of a high-power LED-based solar simulator

    NASA Astrophysics Data System (ADS)

    Toro-Betancur, Veronica; Velásquez-López, Alejandro; Velásquez, David; Acevedo-Gómez, David

    2016-04-01

    The optical design of a High-Power LED based Solar Simulator was made in order to reach the AM1.5G spectrum standards. An optical model of the light emitted by the LEDs was made and used for spectral intensities calculations and the light intensity uniformity was optimized. A class AAA solar simulator was designed using a hexagonal LED distribution.

  17. LED Lighting Facts® Program Supports Accuracy in SSL Product Information

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    Fact sheet that provides a summary of LED Lighting Facts, a program to assure that LED lighting is accurately represented in the marketplace, illustrated by the LED Lighting Facts label to disclose product performance data.

  18. Liquid cooling applications on automotive exterior LED lighting

    NASA Astrophysics Data System (ADS)

    Aktaş, Mehmet; Şenyüz, Tunç; Şenyıldız, Teoman; Kılıç, Muhsin

    2018-02-01

    In this study cooling of a LED unit with heatsink and liquid cooling block which is used in automotive head lamp applications has been investigated numerically and experimentally. Junction temperature of a LED which is cooled with heatsink and liquid cooling block obtained in the experiment. 23°C is used both in the simulation and the experiment phase. Liquid cooling block material is choosed aluminium (Al) and polyamide. All tests and simulation are performed with three different flow rate. Temperature distribution of the designed product is investigated by doing the numerical simulations with a commercially software. In the simulations, fluid flow is assumed to be steady, incompressible and laminar and 3 dimensional (3D) Navier-Stokes equations are used. According to the calculations it is obtained that junction temperature is higher in the heatsink design compared to block cooled one. By changing the block material, it is desired to investigate the variation on the LED junction temperature. It is found that more efficient cooling can be obtained in block cooling by using less volume and weight. With block cooling lifetime of LED can be increased and flux loss can be decreased with the result of decreased junction temperature.

  19. Analysis of LED arrangement in an array with respect to lens geometry

    NASA Astrophysics Data System (ADS)

    Ley, Peer-Phillip; Held, Marcel Philipp; Lachmayer, Roland

    2018-02-01

    Highly adaptive light sources such as LED arrays have been surpassing conventional light sources (halogen, xenon) for automotive applications. Individual LED arrangements within the array, high durability and low energy consumption of the LEDs are some of the reasons. With the introduction of Audi's Matrix beam system, efforts to increase the quantity of pixels were already underway and the stage was practically set for pixel light systems. Current efforts are focused towards the exploration of an optimal LED array density and the use of spatial light modulators. In both cases, one question remains - What arrangement of LEDs is the most suitable in terms of light output efficiency for a given lens geometry? The radiation characteristics of an LED usually shows a Lambertian pattern. Following from the definition of luminous efficacy, this characteristic property of LEDs has a decisive impact on the lens geometry in a given array. Due to the proportional correlation between the lens diameter and the distance of LEDs emission surface to the lens surface. Assuming a constant viewing angle an increase of the distance leads to an increase of the lens diameter. In this paper, two different approaches for an optimized LED array with regards to the LED arrangement will be presented. The introduced designs result from one imaging and one non-imaging optical system, which will be investigated. The paper is concluded with a comparative analysis of the LED array design as a function of the LED pitch and the luminous efficacy.

  20. Degradation mechanism of cyanide in water using a UV-LED/H2O2/Cu2+ system.

    PubMed

    Kim, Tae-Kyoung; Kim, Taeyeon; Jo, Areum; Park, Suhyun; Choi, Kyungho; Zoh, Kyung-Duk

    2018-06-01

    In this study, we developed a UV-LED/H 2 O 2 /Cu 2+ system to remove cyanide, which is typically present in metal electroplating wastewater. The results showed the synergistic effects of UV-LED, H 2 O 2 , and Cu 2+ ions on cyanide removal in comparison with UV-LED photolysis, H 2 O 2 oxidation, UV-LED/H 2 O 2 , and H 2 O 2 /Cu 2+ systems. Cyanide was removed completely in 30 min in the UV-LED/H 2 O 2 /Cu 2+ system, and its loss followed pseudo-first order kinetics. Statistically, both H 2 O 2 and Cu 2+ ions showed positive effects on cyanide removal, but Cu 2+ ions exhibited a greater effect. The highest cyanide removal rate constant (k = 0.179 min -1 ) was achieved at pH 11, but the lowest was achieved at pH 12.5 (k = 0.064 min -1 ) due to the hydrolysis of H 2 O 2 (pK a of H 2 O 2  = 11.75). The presence of dissolved organic matter (DOM) inhibited cyanide removal, and the removal rate constant exhibited a negative linear correlation with DOM (R 2  = 0.987). The removal rate of cyanide was enhanced by the addition of Zn 2+ ions (from 0.179 to 0.457 min -1 ), while the co-existence of Ni 2+ or Cr +6 ion with Cu 2+ ion reduced cyanide removal. The formation of OH radicals in the UV-LED/H 2 O 2 /Cu 2+ system was verified using an aminophenyl fluorescence (APF) probe. Cyanate ions and ammonia were detected as the byproducts of cyanide decomposition. Finally, an acute toxicity reduction of 64.6% was achieved in the system within 1 h, despite a high initial cyanide concentration (100 mg/L). In terms of removal efficiency and toxicity reduction, the UV-LED/H 2 O 2 /Cu 2+ system may be an alternative method of cyanide removal from wastewaters. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Put the Textbooks Away: Preparation and Support for a Middle School One-to-One Laptop Initiative

    ERIC Educational Resources Information Center

    Maninger, Robert M.; Holden, Mary Elizabeth

    2009-01-01

    This study, conducted in the Southwestern United States, investigated teacher and student uses of tablet laptop computers in a one-to-one initiative involving fifth grade through eighth grade students and their teachers. The campus initiative led to higher than expected technology integration and student-teacher and student-student collaborations.…

  2. Healthy Marriage Initiatives: On the Need for Empiricism in Policy Implementation

    ERIC Educational Resources Information Center

    Johnson, Matthew D.

    2012-01-01

    The association between marriage and well-being has led to policies that promote marital interventions and discourage divorce. These include federal initiatives specifically targeting poor couples and couples of color. While there are many prospective studies on marriage that have informed some couple interventions, the studies that are included…

  3. Empirically Derived Lessons Learned about What Makes Peer-Led Exercise Groups Flourish.

    PubMed

    Fletcher, Kathlyn E; Ertl, Kristyn; Ruffalo, Leslie; Harris, LaTamba; Whittle, Jeff

    2017-01-01

    Physical exercise confers many health benefits, but it is difficult to motivate people to exercise. Although community exercise groups may facilitate initiation and persistence in an exercise program, reports regarding factors that allow such groups to flourish are limited. We performed a prospective qualitative evaluation of our experience starting a program of community-based, peer-led exercise groups for military veterans to identify important lessons learned. We synthesized data from structured observations, post-observation debriefings, and focus groups. Our participants were trained peer leaders and exercise group members. Our main outcomes consisted of empirically derived lessons learned during the implementation of a peer-led group exercise program for veterans at multiple community sites. We collected and analyzed data from 40 observation visits (covering 14 sites), 7 transcribed debriefings, and 5 focus groups. We identified five lessons learned. (1) The camaraderie and social aspect of the exercise groups provided motivation for people to stay involved. (2) Shared responsibility and commitment to each other by the group members was instrumental to success. (3) Regular meeting times encouraged participation. (4) Variety, especially getting outdoors, was very popular for some groups. (5) Modest involvement of professionals encouraged ongoing engagement with the program. Both social and programmatic issues influence implementation of group exercise programs for older, predominantly male, veterans. These results should be confirmed in other settings.

  4. LED-based endoscopic light source for spectral imaging

    NASA Astrophysics Data System (ADS)

    Browning, Craig M.; Mayes, Samuel; Favreau, Peter; Rich, Thomas C.; Leavesley, Silas J.

    2016-03-01

    Colorectal cancer is the United States 3rd leading cancer in death rates.1 The current screening for colorectal cancer is an endoscopic procedure using white light endoscopy (WLE). There are multiple new methods testing to replace WLE, for example narrow band imaging and autofluorescence imaging.2 However, these methods do not meet the need for a higher specificity or sensitivity. The goal for this project is to modify the presently used endoscope light source to house 16 narrow wavelength LEDs for spectral imaging in real time while increasing sensitivity and specificity. The process to do such was to take an Olympus CLK-4 light source, replace the light and electronics with 16 LEDs and new circuitry. This allows control of the power and intensity of the LEDs. This required a larger enclosure to house a bracket system for the solid light guide (lightpipe), three new circuit boards, a power source and National Instruments hardware/software for computer control. The results were a successfully designed retrofit with all the new features. The LED testing resulted in the ability to control each wavelength's intensity. The measured intensity over the voltage range will provide the information needed to couple the camera for imaging. Overall the project was successful; the modifications to the light source added the controllable LEDs. This brings the research one step closer to the main goal of spectral imaging for early detection of colorectal cancer. Future goals will be to connect the camera and test the imaging process.

  5. Optimal colour quality of LED clusters based on memory colours.

    PubMed

    Smet, Kevin; Ryckaert, Wouter R; Pointer, Michael R; Deconinck, Geert; Hanselaer, Peter

    2011-03-28

    The spectral power distributions of tri- and tetrachromatic clusters of Light-Emitting-Diodes, composed of simulated and commercially available LEDs, were optimized with a genetic algorithm to maximize the luminous efficacy of radiation and the colour quality as assessed by the memory colour quality metric developed by the authors. The trade-off of the colour quality as assessed by the memory colour metric and the luminous efficacy of radiation was investigated by calculating the Pareto optimal front using the NSGA-II genetic algorithm. Optimal peak wavelengths and spectral widths of the LEDs were derived, and over half of them were found to be close to Thornton's prime colours. The Pareto optimal fronts of real LED clusters were always found to be smaller than those of the simulated clusters. The effect of binning on designing a real LED cluster was investigated and was found to be quite large. Finally, a real LED cluster of commercially available AlGaInP, InGaN and phosphor white LEDs was optimized to obtain a higher score on memory colour quality scale than its corresponding CIE reference illuminant.

  6. Making sense of change: patients' views of diabetes and GP-led integrated diabetes care.

    PubMed

    Burridge, Letitia H; Foster, Michele M; Donald, Maria; Zhang, Jianzhen; Russell, Anthony W; Jackson, Claire L

    2016-02-01

    Health system reform is directed towards better management of diabetes. However, change can be difficult, and patients' perspectives are a key aspect of implementing change. This study investigated patients' perceptions and experiences of type 2 diabetes (T2DM), self-care and engagement with GP-led integrated diabetes care. Qualitative interviews were conducted with purposively selected patients with T2DM following their initial medical appointment in the new model of care. Normalization process theory was used to orientate the thematic analysis, to explain the work of implementing change. Two specialist GP-based complex diabetes services in primary care in Brisbane, Australia. Intervention group patients (n = 30) in a randomized controlled trial to evaluate a model of GP-led integrated care for complex T2DM. Participants' experiences and perceptions of diabetes management and a GP-led model of care. Three themes were identified: sensibility of change, 'diabetic life' and diabetes care alliance. The imperative of change made sense, but some participants experienced dissonance between this rational view and their lived reality. Diabetes invaded life, revealing incongruities between participants' values and living with diabetes. They appreciated a flexible and personalized approach to care. Participants responded to advice in ways that seemed rational within the complexities of their life context. Their diabetes partnerships with health professionals coupled providers' biomedical expertise with patients' contextual expertise. Learning to manage relationships with various health professionals adds to patients' diabetes-related work. Providers need to adopt a flexible, interactive approach and foster trust, to enable better diabetes care. © 2015 John Wiley & Sons Ltd.

  7. LED Outdoor Area Lighting Fact Sheet

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    This fact sheet reviews the major design and specification concerns for outdoor area lighting, and discusses the potential for LED luminaires to save energy while providing high quality lighting for outdoor areas.

  8. Solution processable inverted structure ZnO-organic hybrid heterojuction white LEDs

    NASA Astrophysics Data System (ADS)

    Bano, N.; Hussain, I.; Soomro, M. Y.; EL-Naggar, A. M.; Albassam, A. A.

    2018-05-01

    Improving luminance efficiency and colour purity are the most important challenges for zinc oxide (ZnO)-organic hybrid heterojunction light emitting diodes (LEDs), affecting their large area applications. If ZnO-organic hybrid heterojunction white LEDs are fabricated by a hydrothermal method, it is difficult to obtain pure and stable blue emission from PFO due to the presence of an undesirable green emission. In this paper, we present an inverted-structure ZnO-organic hybrid heterojunction LED to avoid green emission from PFO, which mainly originates during device processing. With this configuration, each ZnO nanorod (NR) forms a discrete p-n junction; therefore, large-area white LEDs can be designed without compromising the junction area. The configuration used for this novel structure is glass/ZnO NRs/PFO/PEDOT:PSS/L-ITO, which enables the development of efficient, large-area and low-cost hybrid heterojunction LEDs. Inverted-structure ZnO-organic hybrid heterojunction white LEDs offer several improvements in terms of brightness, size, colour, external quantum efficiency and a wider applicability as compared to normal architecture LEDs.

  9. Shelf life of fresh meat products under LED or fluorescent lighting.

    PubMed

    Steele, K S; Weber, M J; Boyle, E A E; Hunt, M C; Lobaton-Sulabo, A S; Cundith, C; Hiebert, Y H; Abrolat, K A; Attey, J M; Clark, S D; Johnson, D E; Roenbaugh, T L

    2016-07-01

    Enhanced pork loin chops, beef longissimus lumborum steaks, semimembranosus steaks (superficial and deep portions), ground beef, and ground turkey were displayed under light emitting diode (LED) and fluorescent (FLS) lighting in two multi-shelf, retail display cases with identical operating parameters. Visual and instrumental color, internal product temperature, case temperature, case cycling, thiobarbituric acid reactive substances (TBARS), and Enterobacteriaceae and aerobic plate counts were evaluated. Under LED, beef products (except the deep portion of beef semimembranosus steaks) showed less (P<0.05) visual discoloration. Pork loin chops had higher (P<0.05) L* values for LED lighting. Other than beef longissimus lumborum steaks, products displayed under LED lights had colder internal temperatures than products under FLS lights (P<0.05). Under LED, pork loin chops, ground turkey, and beef semimembranosus steaks had higher (P<0.05) values for TBARS. LED provides colder case and product temperatures, more case efficiency, and extended color life by at least 0.5d for longissimus and semimembranosus steaks; however, some LED cuts showed increased lipid oxidation. Copyright © 2016. Published by Elsevier Ltd.

  10. Financial services employees' experience of peer-led and clinician-led critical incident stress debriefing following armed robberies.

    PubMed

    Simms-Ellis, R; Madill, A

    2001-01-01

    This study investigates financial services employees' experience of critical incident stress debriefing (CISD) and their views about peers and clinicians as facilitators. Semi-structured interview accounts of four participants who had experienced both peer-led and clinician-led CISD were analyzed using grounded theory. A core category, ambivalence, permeated each interview and divided into two poles: pathologizing and normalizing. The most frequently occurring sub-category was a dislike of professionalism. Participants preferred the peer debriefer who was perceived to have more personal involvement and with whom they felt more empowered and understood. The findings suggest that the status of the debriefer as 'peer' or 'clinician' may be a crucial variable in the effectiveness of CISD and should be considered when reviewing the outcome literature.

  11. A Review of Empirical Analyses of Disinvestment Initiatives.

    PubMed

    Chambers, James D; Salem, Mark N; D'Cruz, Brittany N; Subedi, Prasun; Kamal-Bahl, Sachin J; Neumann, Peter J

    Disinvesting in low-value health care services provides opportunities for investment in higher value care and thus an increase in health care efficiency. To identify international experience with disinvestment initiatives and to review empirical analyses of disinvestment initiatives. We performed a literature search using the PubMed database to identify international experience with disinvestment initiatives. We also reviewed empirical analyses of disinvestment initiatives. We identified 26 unique disinvestment initiatives implemented across 11 countries. Nineteen addressed multiple intervention types, six addressed only drugs, and one addressed only devices. We reviewed 18 empirical analyses of disinvestment initiatives: 7 reported that the initiative was successful, 8 reported that the initiative was unsuccessful, and 3 reported that findings were mixed; that is, the study considered multiple services and reported a decrease in the use of some but not others. Thirty-seven low-value services were evaluated across the 18 empirical analyses, for 14 (38%) of which the disinvestment initiative led to a decline in use. Six of the seven studies that reported the disinvestment initiative to be successful included an attempt to promote the disinvestment initiative among participating clinicians. The success of disinvestment initiatives has been mixed, with fewer than half the identified empirical studies reporting that use of the low-value service was reduced. Our findings suggest that promotion of the disinvestment initiative among clinicians is a key component to the success of the disinvestment initiative. Copyright © 2017 International Society for Pharmacoeconomics and Outcomes Research (ISPOR). Published by Elsevier Inc. All rights reserved.

  12. Visual color matching system based on RGB LED light source

    NASA Astrophysics Data System (ADS)

    Sun, Lei; Huang, Qingmei; Feng, Chen; Li, Wei; Wang, Chaofeng

    2018-01-01

    In order to study the property and performance of LED as RGB primary color light sources on color mixture in visual psychophysical experiments, and to find out the difference between LED light source and traditional light source, a visual color matching experiment system based on LED light sources as RGB primary colors has been built. By simulating traditional experiment of metameric color matching in CIE 1931 RGB color system, it can be used for visual color matching experiments to obtain a set of the spectral tristimulus values which we often call color-matching functions (CMFs). This system consists of three parts: a monochromatic light part using blazed grating, a light mixing part where the summation of 3 LED illuminations are to be visually matched with a monochromatic illumination, and a visual observation part. The three narrow band LEDs used have dominant wavelengths of 640 nm (red), 522 nm (green) and 458 nm (blue) respectively and their intensities can be controlled independently. After the calibration of wavelength and luminance of LED sources with a spectrophotometer, a series of visual color matching experiments have been carried out by 5 observers. The results are compared with those from CIE 1931 RGB color system, and have been used to compute an average locus for the spectral colors in the color triangle, with white at the center. It has been shown that the use of LED is feasible and has the advantages of easy control, good stability and low cost.

  13. Failure modes and effects criticality analysis and accelerated life testing of LEDs for medical applications

    NASA Astrophysics Data System (ADS)

    Sawant, M.; Christou, A.

    2012-12-01

    While use of LEDs in Fiber Optics and lighting applications is common, their use in medical diagnostic applications is not very extensive. Since the precise value of light intensity will be used to interpret patient results, understanding failure modes [1-4] is very important. We used the Failure Modes and Effects Criticality Analysis (FMECA) tool to identify the critical failure modes of the LEDs. FMECA involves identification of various failure modes, their effects on the system (LED optical output in this context), their frequency of occurrence, severity and the criticality of the failure modes. The competing failure modes/mechanisms were degradation of: active layer (where electron-hole recombination occurs to emit light), electrodes (provides electrical contact to the semiconductor chip), Indium Tin Oxide (ITO) surface layer (used to improve current spreading and light extraction), plastic encapsulation (protective polymer layer) and packaging failures (bond wires, heat sink separation). A FMECA table is constructed and the criticality is calculated by estimating the failure effect probability (β), failure mode ratio (α), failure rate (λ) and the operating time. Once the critical failure modes were identified, the next steps were generation of prior time to failure distribution and comparing with our accelerated life test data. To generate the prior distributions, data and results from previous investigations were utilized [5-33] where reliability test results of similar LEDs were reported. From the graphs or tabular data, we extracted the time required for the optical power output to reach 80% of its initial value. This is our failure criterion for the medical diagnostic application. Analysis of published data for different LED materials (AlGaInP, GaN, AlGaAs), the Semiconductor Structures (DH, MQW) and the mode of testing (DC, Pulsed) was carried out. The data was categorized according to the materials system and LED structure such as AlGaInP-DH-DC, Al

  14. Counting on commitment; the quality of primary care-led diabetes management in a system with minimal incentives

    PubMed Central

    2011-01-01

    Background The aim of the present study was to assess the performance of three primary care-led initiatives providing structured care to patients with Type 2 diabetes in Ireland, a country with minimal incentives to promote the quality of care. Methods Data, from three primary care initiatives, were available for 3010 adult patients with Type 2 diabetes. Results were benchmarked against the national guidelines for the management of Type 2 diabetes in the community and results from the National Diabetes Audit (NDA) for England (2008/2009) and the Scottish Diabetes Survey (2009). Results The recording of clinical processes of care was similar to results in the UK however the recording of lifestyle factors was markedly lower. Recording of HbA1c, blood pressure and lipids exceeded 85%. Recording of retinopathy screening (71%) was also comparable to England (77%) and Scotland (90%). Only 63% of patients had smoking status recorded compared to 99% in Scotland while 70% had BMI recorded compared to 89% in England. A similar proportion of patients in this initiative and the UK achieved clinical targets. Thirty-five percent of patients achieved a target HbA1c of < 6.5% (< 48 mmol/mol) compared to 25% in England. Applying the NICE target for blood pressure (≤ 140/80 mmHg), 54% of patients reached this target comparable to 60% in England. Slightly less patients were categorised as obese (> 30 kg/m2) in Ireland (50%, n = 1060) compared to Scotland (54%). Conclusions This study has demonstrated what can be achieved by proactive and interested health professionals in the absence of national infrastructure to support high quality diabetes care. The quality of primary care-led diabetes management in the three initiatives studied appears broadly consistent with results from the UK with the exception of recording lifestyle factors. The challenge facing health systems is to establish quality assurance a responsibility for all health care professionals rather than the subject of

  15. Counting on commitment; the quality of primary care-led diabetes management in a system with minimal incentives.

    PubMed

    Mc Hugh, Sheena; Marsden, Paul; Brennan, Carmel; Murphy, Katie; Croarkin, Celine; Moran, Joe; Harkins, Velma; Perry, Ivan J

    2011-12-28

    The aim of the present study was to assess the performance of three primary care-led initiatives providing structured care to patients with Type 2 diabetes in Ireland, a country with minimal incentives to promote the quality of care. Data, from three primary care initiatives, were available for 3010 adult patients with Type 2 diabetes. Results were benchmarked against the national guidelines for the management of Type 2 diabetes in the community and results from the National Diabetes Audit (NDA) for England (2008/2009) and the Scottish Diabetes Survey (2009). The recording of clinical processes of care was similar to results in the UK however the recording of lifestyle factors was markedly lower. Recording of HbA1c, blood pressure and lipids exceeded 85%. Recording of retinopathy screening (71%) was also comparable to England (77%) and Scotland (90%). Only 63% of patients had smoking status recorded compared to 99% in Scotland while 70% had BMI recorded compared to 89% in England. A similar proportion of patients in this initiative and the UK achieved clinical targets. Thirty-five percent of patients achieved a target HbA1c of < 6.5% (< 48 mmol/mol) compared to 25% in England. Applying the NICE target for blood pressure (≤ 140/80 mmHg), 54% of patients reached this target comparable to 60% in England. Slightly less patients were categorised as obese (> 30 kg/m²) in Ireland (50%, n = 1060) compared to Scotland (54%). This study has demonstrated what can be achieved by proactive and interested health professionals in the absence of national infrastructure to support high quality diabetes care. The quality of primary care-led diabetes management in the three initiatives studied appears broadly consistent with results from the UK with the exception of recording lifestyle factors. The challenge facing health systems is to establish quality assurance a responsibility for all health care professionals rather than the subject of special interest for a few.

  16. Design of crossed-mirror array to form floating 3D LED signs

    NASA Astrophysics Data System (ADS)

    Yamamoto, Hirotsugu; Bando, Hiroki; Kujime, Ryousuke; Suyama, Shiro

    2012-03-01

    3D representation of digital signage improves its significance and rapid notification of important points. Our goal is to realize floating 3D LED signs. The problem is there is no sufficient device to form floating 3D images from LEDs. LED lamp size is around 1 cm including wiring and substrates. Such large pitch increases display size and sometimes spoils image quality. The purpose of this paper is to develop optical device to meet the three requirements and to demonstrate floating 3D arrays of LEDs. We analytically investigate image formation by a crossed mirror structure with aerial aperture, called CMA (crossed-mirror array). CMA contains dihedral corner reflectors at each aperture. After double reflection, light rays emitted from an LED will converge into the corresponding image point. We have fabricated CMA for 3D array of LEDs. One CMA unit contains 20 x 20 apertures that are located diagonally. Floating image of LEDs was formed in wide range of incident angle. The image size of focused beam agreed to the apparent aperture size. When LEDs were located three-dimensionally (LEDs in three depths), the focused distances were the same as the distance between the real LED and the CMA.

  17. City Beats: A Creative Community Partnership Initiative at ArtPlay

    ERIC Educational Resources Information Center

    Jeanneret, Neryl; Brown, Robert

    2012-01-01

    The City of Melbourne's ArtPlay is open to children and young people aged 3-13 years, and provides a wide range of artist-led programs that serve a broad community within and outside the municipality. Its sister facility, Signal, caters for young people 13-22 years. An Australia Council of the Arts funded Creative Community Partnership Initiative,…

  18. Medical lighting composed of LED arrays for surgical operation

    NASA Astrophysics Data System (ADS)

    Shimada, Junichi; Kawakami, Yoichi; Fujita, Shigeo

    2001-05-01

    Everywhere in the world, the highest quality and quantity of lighting is required during the surgical operations. However, the surgical approach has had many types and various angles, common ceiling surgical halogen lighting system cannot provide an adequate amount of beams because the surgeons' heads hinder the illuminations from reaching the operation field. Here, we newly design surgical lighting system composed of white LEDs equipped on both sides of goggles, which controls the lighting beams to the gazing point. With this system, it is just needed for surgeons to wear light plastic goggles with high quality LEDs made by Nichia. In fact, we have succeeded in the first internal shunt operation in the left forearm using the surgical LED lighting system on 11th Sept 2000. The electrical power for the system was supplied from lithium-ion battery for 2 hours. Since the white LEDs used were composed of InGaN- blue-emitters and YAG-yellow-phosphors, the color rendering property was not sufficient in the reddish colors. Therefore, in the next approach, it is very important to develop the spectral distribution of white LED to render inherent color of raw flesh such as skin, blood, fat tissue and internal organs.

  19. Investigation of thermal management technique in blue LED airport taxiway fixtures

    NASA Astrophysics Data System (ADS)

    Gu, Yimin; Baker, Alex; Narendran, Nadarajah

    2007-09-01

    On airport runways, blue light fixtures denote taxiways between the runway and the airport terminal. Blue optics transmit mostly short-wavelength radiation, which makes traditional incandescent lamps a poor choice of light source; the resulting fixture efficiency could be less than one percent. LEDs are replacing incandescent lamps in this application. But unlike incandescent sources, LEDs do not radiate enough heat to melt ice and snow from the fixture optics. To meet Federal Aviation Administration (FAA) regulations for weatherability, some LED-based fixtures incorporate electric heaters that, when switched on, nearly negate the energy-savings benefit of converting to LED sources. In this study, we explored methods for conduction and convection of LED junction heat to taxiway fixture optics for the purpose of minimizing snow and ice buildup. A more efficient LED-based system compared to incandescent that would require no additional heaters was demonstrated.

  20. Time dependence of composite shrinkage using halogen and LED light curing.

    PubMed

    Uhl, Alexander; Mills, Robin W; Rzanny, Angelika E; Jandt, Klaus D

    2005-03-01

    The polymerization shrinkage of light cured dental composites presents the major drawback for these aesthetically adaptable restorative materials. LED based light curing technology has recently become commercially available. Therefore, the aim of the present study was to investigate if there was a statistically significant difference in linear and volumetric composite shrinkage strain if a LED LCU is used for the light curing process rather than a conventional halogen LCU. The volumetric shrinkage strain was determined using the Archimedes buoyancy principle after 5, 10, 20, 40 s of light curing and after 120 s following the 40 s light curing time period. The linear shrinkage strain was determined with a dynamic mechanical analyzer for the composites Z100, Spectrum, Solitaire2 and Definite polymerized with the LCUs Trilight (halogen), Freelight I (LED) and LED63 (LED LCU prototype). The changes in irradiance and spectra of the LCUs were measured after 0, 312 and 360 min of duty time. In general there was no considerable difference in shrinkage of the composites Z100, Spectrum or Solitaire2 when the LED63 was used instead of the Trilight. There was, however, a statistically significant difference in shrinkage strain when the composite Definite was polymerized with the LED63 instead of the Trilight. The spectrum of the Trilight changed during the experiment considerably whereas the LED63 showed an almost constant light output. The Freelight I dropped considerably in irradiance and had to be withdrawn from the study because of technical problems. The composites containing only the photoinitiator camphorquinone showed similar shrinkage strain behaviour when a LED or halogen LCU is used for the polymerization. The irradiance of some LED LCUs can also decrease over time and should therefore be checked on a regular basis.

  1. Hardness Evaluation of Composite Resins Cured with QTH and LED

    PubMed Central

    Esmaeili, Behnaz; Safarcherati, Hengameh; Vaezi, Assila

    2014-01-01

    Background and aims. Today light cured composites are widely used. Physical and mechanical properties of composites are related to the degree of conversion. Light curing unit (LCU) is an important factor for composite polymerization. Aim of this study is evaluation of composite resins hardness using halogen and LED light curing units. Materials and methods. In this study, 30 samples of Filtek Z250 and C-Fill composite resins were provided. Samples were light cured with Ultralume2, Valo and Astralis7. Vickers hardness number (VHN) was measured in 0, 1, 2 mm depth. Statistical analysis used: Data were analysed by SPSS software and compared with each other by T-test, one-way and two-way ANOVA and Post-hoc Tukey test. Results. In Filtek Z250, at top surface, VHN of Ultralume2 was higher than VHN of Valo (P = 0.02) and Astralis7 (P =0.04), but in depth of 1, 2 mm, VHN of Ultralume2 and Astralis7 were almost the same and both LCUs were more than Valo which the difference between Ultralume2 and Valo was significant in depth of 1mm (0.05) and 2mm (0.02). In C-Fill composite, at top surface, Astralis7 showed higher VHN, but in depth of 2 mm, performance of all devices were rather simi-lar. Conclusion. In Z250, which contains camphorquinone initiator, light cure LED Ultra-lume2 with narrow wavelength showed higher hardness number than Valo. In C-fill, in top surface, Astralis7 with more exposure time, resulted higher VHN. But In depth of 2 mm, various light curing devices had rather similar hardness number. PMID:25024838

  2. Freeform lens design for LED collimating illumination.

    PubMed

    Chen, Jin-Jia; Wang, Te-Yuan; Huang, Kuang-Lung; Liu, Te-Shu; Tsai, Ming-Da; Lin, Chin-Tang

    2012-05-07

    We present a simple freeform lens design method for an application to LED collimating illumination. The method is derived from a basic geometric-optics analysis and construction approach. By using this method, a highly collimating lens with LED chip size of 1.0 mm × 1.0 mm and optical simulation efficiency of 86.5% under a view angle of ± 5 deg is constructed. To verify the practical performance of the lens, a prototype of the collimator lens is also made, and an optical efficiency of 90.3% with a beam angle of 4.75 deg is measured.

  3. Using UAVs to Conduct Student-led Research Projects

    NASA Astrophysics Data System (ADS)

    Olds, S. E.; Lewis, P. M., Jr.

    2016-12-01

    Recreational drones can inspire students to initiate research projects. These "toys" have a low cost (<$100), low weight (< 250 g, so do not require FAA registration), and an ability to carry small instrument packages, making them an ideal platform for conducting innovative investigations. This session describes an initiative by the Federation of Earth Science Information Partners (ESIP) Education Committee to compile and distribute a free e-book that will encourage learners to use drones for science investigations. Our goal is to inspire learners to use UAVs to carry scientific instruments and/or capture imagery to conduct local-scale investigations. Experiments such as discovering their vehicle's maximum payload help learners understand what sensors they can use (or build) to conduct research. The e-book will encourage learners to practice UAV civility and safety through a pre-flight checklist and flying guidelines, and to consider science objectives and flight team roles in performing investigations. Activities also advocate for robust data and metadata-collection practices. Suggested activities encompass repeat photography investigations as well as engineering design skills such as designing a camera mount to obtain nadir or oblique imagery. Learners can also move to more sophisticated research using photogrammetric skills such as taking overlapping photographs to create 3D structure from motion (SfM) models. To encourage the use of onboard sensors, the team worked with an engineer to build a 33-gram prototype environmental logger called SABEL (Shelley [Olds] and Bob [Ellis]'s Environmental Logger). Assembled on an Arduino board, SABEL collects temperature, humidity, and GPS position. This presentation will provide examples of student-led investigations, instructions for building the SABEL sensor package, and the status of the new e-book compilation of student-focused activities using recreational drones to pursue science, math, engineering, and technology

  4. Color Degradation of Textiles with Natural Dyes and of Blue Scale Standards Exposed to White LED Lamps:Evaluation of White LED Lamps for Effectiveness as Museum Lighting

    NASA Astrophysics Data System (ADS)

    Ishii, Mie; Moriyama, Takayoshi; Toda, Masahiro; Kohmoto, Kohtaro; Saito, Masako

    White light-emitting diodes (LED) are well suited for museum lighting because they emit neither UV nor IR radiation, which damage artifacts. The color degradation of natural dyes and blue scale standards (JIS L 0841) by white LED lamps are examined, and the performance of white LED lamps for museum lighting is evaluated. Blue scale standard grades 1-6 and silk fabrics dyed with 22 types of natural dyes classified as mid to highly responsive in a CIE technical report (CIE157:2004) were exposed to five types of white LED lamps using different luminescence methods and color temperatures. Color changes were measured at each 15000 lx·hr (500 lx at fabric surface × 300 hr) interval ten times. The accumulated exposure totaled 150000 lx·hr. The data on conventional white LED lamps and previously reported white fluorescent (W) and museum fluorescent (NU) lamps was evaluated. All the white LED lamps showed lower fading rates compared with a W lamp on a blue scale grade 1. The fading rate of natural dyes in total was the same between an NU lamp (3000 K) and a white LED lamp (2869 K). However, yellow natural dyes showed higher fading rates with the white LED lamp. This tendency is due to the high power characteristic of the LED lamp around 400-500 nm, which possibly contributes to the photo-fading action on the dyes. The most faded yellow dyes were Ukon (Curcuma longa L.) and Kihada (Phellodendron amurense Rupr.), and these are frequently used in historic artifacts such as kimono, wood-block prints, and scrolls. From a conservation point of view, we need to continue research on white LED lamps for use in museum lighting.

  5. Midwife-led continuity models versus other models of care for childbearing women.

    PubMed

    Sandall, Jane; Soltani, Hora; Gates, Simon; Shennan, Andrew; Devane, Declan

    2016-04-28

    = 17,561; studies = 13; high quality evidence). Women who had midwife-led continuity models of care were more likely to experience spontaneous vaginal birth (average RR 1.05, 95% CI 1.03 to 1.07; participants = 16,687; studies = 12; high quality). There were no differences between groups for caesarean births or intact perineum.For the secondary outcomes, women who had midwife-led continuity models of care were less likely to experience amniotomy (average RR 0.80, 95% CI 0.66 to 0.98; participants = 3253; studies = four), episiotomy (average RR 0.84, 95% CI 0.77 to 0.92; participants = 17,674; studies = 14) and fetal loss less than 24 weeks and neonatal death (average RR 0.81, 95% CI 0.67 to 0.98; participants = 15,645; studies = 11). Women who had midwife-led continuity models of care were more likely to experience no intrapartum analgesia/anaesthesia (average RR 1.21, 95% CI 1.06 to 1.37; participants = 10,499; studies = seven), have a longer mean length of labour (hours) (mean difference (MD) 0.50, 95% CI 0.27 to 0.74; participants = 3328; studies = three) and more likely to be attended at birth by a known midwife (average RR 7.04, 95% CI 4.48 to 11.08; participants = 6917; studies = seven). There were no differences between groups for fetal loss equal to/after 24 weeks and neonatal death, induction of labour, antenatal hospitalisation, antepartum haemorrhage, augmentation/artificial oxytocin during labour, opiate analgesia, perineal laceration requiring suturing, postpartum haemorrhage, breastfeeding initiation, low birthweight infant, five-minute Apgar score less than or equal to seven, neonatal convulsions, admission of infant to special care or neonatal intensive care unit(s) or in mean length of neonatal hospital stay (days).Due to a lack of consistency in measuring women's satisfaction and assessing the cost of various maternity models, these outcomes were reported narratively. The majority of included studies reported a higher rate of maternal satisfaction in

  6. Midwife-led continuity models versus other models of care for childbearing women.

    PubMed

    Sandall, Jane; Soltani, Hora; Gates, Simon; Shennan, Andrew; Devane, Declan

    2015-09-15

    quality evidence). Women who had midwife-led continuity models of care were more likely to experience spontaneous vaginal birth (average RR 1.05, 95% CI 1.03 to 1.07; participants = 16,687; studies = 12; high quality). There were no differences between groups for caesarean births or intact perineum.For the secondary outcomes, women who had midwife-led continuity models of care were less likely to experience amniotomy (average RR 0.80, 95% CI 0.66 to 0.98; participants = 3253; studies = 4), episiotomy (average RR 0.84, 95% CI 0.77 to 0.92; participants = 17,674; studies = 14) and fetal loss/neonatal death before 24 weeks (average RR 0.81, 95% CI 0.67 to 0.98; participants = 15,645; studies = 11). Women who had midwife-led continuity models of care were more likely to experience no intrapartum analgesia/anaesthesia (average RR 1.21, 95% CI 1.06 to 1.37; participants = 10,499; studies = 7), have a longer mean length of labour (hours) (mean difference (MD) 0.50, 95% CI 0.27 to 0.74; participants = 3328; studies = 3) and more likely to be attended at birth by a known midwife (average RR 7.04, 95% CI 4.48 to 11.08; participants = 6917; studies = 7). There were no differences between groups for fetal loss or neonatal death more than or equal to 24 weeks, induction of labour, antenatal hospitalisation, antepartum haemorrhage, augmentation/artificial oxytocin during labour, opiate analgesia, perineal laceration requiring suturing, postpartum haemorrhage, breastfeeding initiation, low birthweight infant, five-minute Apgar score less than or equal to seven, neonatal convulsions, admission of infant to special care or neonatal intensive care unit(s) or in mean length of neonatal hospital stay (days).Due to a lack of consistency in measuring women's satisfaction and assessing the cost of various maternity models, these outcomes were reported narratively. The majority of included studies reported a higher rate of maternal satisfaction in midwife-led continuity models of care. Similarly

  7. Interior LED Lighting Technology. Navy Energy Technology Validation (Techval) Program

    DTIC Science & Technology

    2015-09-01

    usually on most of the time. • Consider replacing existing CFL, high-intensity discharge (HID), or halogen lamp light fixtures/ lamps with LED fixtures... lamps . What is the Technology? An LED is a semiconductor-diode that emits light when power is applied. A driver is used, much as a ballast, to...available in integrated luminaires that can be used to replace existing luminaires. LEDs are also available as direct replacement lamps for many

  8. Energy saving through LED in signaling functions for automotive exterior lighting

    NASA Astrophysics Data System (ADS)

    Bony, Alexis; Hamami, Khaled; Tebbe, Frank; Mertens, Jens

    2011-05-01

    Safety considerations have always driven the way for improving exterior automotive lighting legal requirements. With the recent adoption of day-time running lamps for passenger cars, the steadily increasing need for reduction of vehicle power consumption has led to the introduction of LED-based day-time running lamps. Solutions with incandescent bulbs have also been implemented, as they present price advantages while offering limited design perspectives. In the meantime, technology developments has turned LED sources into ideal candidates for daytime running lamps by increasing their lumen per watt efficiency ratio towards values around 100 lm/W or higher. In this work, taking as an example the new Mercedes-Benz roadster SLK (R172), we present the first single LED daytime- running lamp, with a total power consumption below 5W per vehicle. After reviewing legal requirements, the optical and electronic concepts are discussed. Details on the tail lamp LED functions are also discussed, and particularly the advantages from the realization of fog lamp with LEDs.

  9. Efficient conceptual design for LED-based pixel light vehicle headlamps

    NASA Astrophysics Data System (ADS)

    Held, Marcel Philipp; Lachmayer, Roland

    2017-12-01

    High-resolution vehicle headlamps represent a future-oriented technology that can be used to increase traffic safety and driving comfort. As a further development to the current Matrix Beam headlamps, LED-based pixel light systems enable ideal lighting functions (e.g. projection of navigation information onto the road) to be activated in any given driving scenario. Moreover, compared to other light-modulating elements such as DMDs and LCDs, instantaneous LED on-off toggling provides a decisive advantage in efficiency. To generate highly individualized light distributions for automotive applications, a number of approaches using an LED array may be pursued. One approach is to vary the LED density in the array so as to output the desired light distribution. Another notable approach makes use of an equidistant arrangement of the individual LEDs together with distortion optics to formulate the desired light distribution. The optical system adjusts the light distribution in a manner that improves resolution and increases luminous intensity of the desired area. An efficient setup for pixel generation calls for one lens per LED. Taking into consideration the limited space requirements of the system, this implies that the luminous flux, efficiency and resolution image parameters are primarily controlled by the lens dimensions. In this paper a concept for an equidistant LED array arrangement utilizing distortion optics is presented. The paper is divided into two parts. The first part discusses the influence of lens geometry on the system efficiency whereas the second part investigates the correlation between resolution and luminous flux based on the lens dimensions.

  10. Enhanced light extraction in tunnel junction-enabled top emitting UV LEDs

    DOE PAGES

    Zhang, Yuewei; Allerman, Andrew A.; Krishnamoorthy, Sriram; ...

    2016-04-11

    The efficiency of ultra violet LEDs has been critically limited by the absorption losses in p-type and metal layers. In this work, surface roughening based light extraction structures are combined with tunneling based p-contacts to realize highly efficient top-side light extraction efficiency in UV LEDs. Surface roughening of the top n-type AlGaN contact layer is demonstrated using self-assembled Ni nano-clusters as etch mask. The top surface roughened LEDs were found to enhance external quantum efficiency by over 40% for UV LEDs with a peak emission wavelength of 326 nm. The method described here can enable highly efficient UV LEDs withoutmore » the need for complex manufacturing methods such as flip chip bonding.« less

  11. Influence of interconnection on the long-term reliability of UV LED packages

    NASA Astrophysics Data System (ADS)

    Nieland, S.; Mitrenga, D.; Karolewski, D.; Brodersen, O.; Ortlepp, T.

    2017-02-01

    High power LEDs have conquered the mass market in recent years. Besides the main development focus to achieve higher productivity in the field of visible semiconductor LED processing, the wavelength range is further enhanced by active research and development in the direction of UVA / UVB / UVC. UVB and UVC LEDs are new and promising due to their numerous advantages. UV LEDs emit in a near range of one single emission peak with a width (FWHM) below 15 nm compared to conventional mercury discharge lamps and xenon sources, which show broad spectrums with many emission peaks over a wide range of wavelengths. Furthermore, the UV LED size is in the range of a few hundred microns and offers a high potential of significant system miniaturization. Of course, LED efficiency, lifetime and output power have to be increased [1]. Lifetime limiting issues of UVB/UVC-LED are the very high thermal stress in the chip resulting from the higher forward voltages (6-10 V @ 350 mA), the lower external quantum efficiency, below 10 % (most of the power disappears as heat), and the thermal resistance Rth of conventional LED packages being not able to dissipate these large amounts of heat for spreading. Beside the circuit boards and submounts which should have maximum thermal conductivity, the dimension of contacts as well as the interconnection of UV LED to the submount/package determinates the resolvable amount of heat [2]. In the paper different innovative interconnection techniques for UVC-LED systems will be discussed focused on the optimization of thermal conductivity in consideration of the assembly costs. Results on thermal simulation for the optimal contact dimensions and interconnections will be given. In addition, these theoretical results will be compared with results on electrical characterization as well as IR investigations on real UV LED packages in order to give recommendations for optimal UV LED assembly.

  12. Bridging the "green gap" of LEDs: giant light output enhancement and directional control of LEDs via embedded nano-void photonic crystals.

    PubMed

    Tsai, Yu-Lin; Liu, Che-Yu; Krishnan, Chirenjeevi; Lin, Da-Wei; Chu, You-Chen; Chen, Tzu-Pei; Shen, Tien-Lin; Kao, Tsung-Sheng; Charlton, Martin D B; Yu, Peichen; Lin, Chien-Chung; Kuo, Hao-Chung; He, Jr-Hau

    2016-01-14

    Green LEDs do not show the same level of performance as their blue and red cousins, greatly hindering the solid-state lighting development, which is the so-called "green gap". In this work, nano-void photonic crystals (NVPCs) were fabricated to embed within the GaN/InGaN green LEDs by using epitaxial lateral overgrowth (ELO) and nano-sphere lithography techniques. The NVPCs act as an efficient scattering back-reflector to outcouple the guided and downward photons, which not only boost the light extraction efficiency of LEDs with an enhancement of 78% but also collimate the view angle of LEDs from 131.5° to 114.0°. This could be because of the highly scattering nature of NVPCs which reduce the interference giving rise to Fabry-Perot resonance. Moreover, due to the threading dislocation suppression and strain relief by the NVPCs, the internal quantum efficiency was increased by 25% and droop behavior was reduced from 37.4% to 25.9%. The enhancement of light output power can be achieved as high as 151% at a driving current of 350 mA. Giant light output enhancement and directional control via NVPCs point the way towards a promising avenue of solid-state lighting.

  13. Materials and Designs for High-Efficacy LED Light Engines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ibbetson, James; Gresback, Ryan

    Cree, Inc. conducted a narrow-band downconverter (NBD) materials development and implementation program which will lead to warm-white LED light engines with enhanced efficacy via improved spectral efficiency with respect to the human eye response. New red (600-630nm) NBD materials could result in as much as a 20% improvement in warm-white efficacy at high color quality relative to conventional phosphor-based light sources. Key program innovations included: high quantum yield; narrow peak width; minimized component-level losses due to “cross-talk” and light scattering among red and yellow-green downconverters; and improved reliability to reach parity with conventional phosphors. NBD-enabled downconversion efficiency gains relative tomore » conventional phosphors yielded an end-of-project LED light engine efficacy of >160 lm/W at room temperature and 35 A/cm2, with a correlated color temperature (CCT) of ~3500K and >90 CRI (Color Rending Index). NBD-LED light engines exhibited equivalent luminous flux and color point maintenance at >1,000 hrs. of highly accelerated reliability testing as conventional phosphor LEDs. A demonstration luminaire utilizing an NBD-based LED light engine had a steady-state system efficacy of >150 lm/W at ~3500K and >90 CRI, which exceeded the 2014 DOE R&D Plan luminaire milestone for FY17 of >150 lm/W at just 80 CRI.« less

  14. LED-based high-speed visible light communications

    NASA Astrophysics Data System (ADS)

    Chi, Nan; Shi, Meng; Zhao, Yiheng; Wang, Fumin; Shi, Jianyang; Zhou, Yingjun; Lu, Xingyu; Qiao, Liang

    2018-01-01

    We are seeing a growing use of light emitting diodes (LEDs) in a range of applications including lighting, TV and backlight board screen, display etc. In comparison with the traditional incandescent and fluorescent light bulbs, LEDs offer long life-space, much higher energy efficiency, high performance cost ratio and above all very fast switching capability. LED based Visible Light Communications (VLC) is an emerging field of optical communications that focuses on the part of the electromagnetic spectrum that humans can see. Depending on the transmission distance, we can divide the whole optical network into two categories, long haul and short haul. Visible light communication can be a promising candidate for short haul applications. In this paper, we outline the configuration of VLC, its unique benefits, and describe the state of the art research contributions consisting of advanced modulation formats including adaptive bit loading OFDM, carrierless amplitude and phase (CAP), pulse amplitude modulation (PAM) and single carrier Nyquist, linear equalization and nonlinear distortion mitigation based on machine learning, quasi-balanced coding and phase-shifted Manchester coding. These enabling technologies can support VLC up to 10Gb/s class free space transmission.

  15. Blue laser diode (LD) and light emitting diode (LED) applications

    NASA Astrophysics Data System (ADS)

    Bergh, Arpad A.

    2004-09-01

    The family of blue LEDs, edge emitting and surface emitting lasers, enable a number of applications. Blue lasers are used in digital applications such as optical storage in high density DVDs. The resolution of the spot size and hence the storage density is diffraction limited and is inversely proportional to the square of the wavelength of the laser. Other applications include printing, optical scanners, and high-resolution photo-lithography.As light emitters, blue LEDs are used for signaling and in direct view large area emissive displays. They are also making inroads into signage and LCD back-lighting, mobile platforms, and decorative accent lighting in curtains, furniture, etc.Blue LEDs produce white light either with phosphor wavelength converters or in combination with red and green LEDs. The full potential of LED light sources will require three devices to enable complete control over color and intensity.Sensing and medical/bio applications have a major impact on home security, on monitoring the environment, and on health care. New emerging diagnostic and therapeutic applications will improve the quality and reduce the cost of health care.

  16. Initial state with shear in peripheral heavy ion collisions

    NASA Astrophysics Data System (ADS)

    Magas, V. K.; Gordillo, J.; Strottman, D.; Xie, Y. L.; Csernai, L. P.

    2018-06-01

    In the present work we propose a new way of constructing the initial state for further hydrodynamic simulation of relativistic heavy ion collisions based on Bjorken-like solution applied streak by streak in the transverse plane. Previous fluid dynamical calculations in Cartesian coordinates with an initial state based on a streak by streak Yang-Mills field led for peripheral higher energy collisions to large angular momentum, initial shear flow and significant local vorticity. Recent experiments verified the existence of this vorticity via the resulting polarization of emitted Λ and Λ ¯ particles. At the same time parton cascade models indicated the existence of more compact initial state configurations, which we are going to simulate in our approach. The proposed model satisfies all the conservation laws, including conservation of a strong initial angular momentum, which is present in noncentral collisions. As a consequence of this large initial angular momentum we observe the rotation of the whole system as well as the fluid shear in the initial state, which leads to large flow vorticity. Another advantage of the proposed model is that the initial state can be given in both [t,x,y,z] and [τ ,x ,y ,η ] coordinates and thus can be tested by all 3+1D hydrodynamical codes which exist in the field.

  17. LEDs Illuminate Bulbs for Better Sleep, Wake Cycles

    NASA Technical Reports Server (NTRS)

    2015-01-01

    Life on the International Space Station (ISS) wreaks havoc on an astronaut’s biological rhythms, and one way NASA mitigates the problem is through the use of LED lighting to alternately stimulate energy and focus and induce relaxation. Satellite Beach, Florida-based Lighting Science partnered with Kennedy Space Center to commercialize an LED system designed for the ISS, resulting in its DefinityDigital product line of light bulbs now used in numerous homes, hotel chains, and resorts.

  18. A novel amblyopia treatment system based on LED light source

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling

    2011-05-01

    A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.

  19. A novel amblyopia treatment system based on LED light source

    NASA Astrophysics Data System (ADS)

    Zhang, Xiaoqing; Chen, Qingshan; Wang, Xiaoling

    2010-12-01

    A novel LED (light emitting diode) light source of five different colors (white, red, green, blue and yellow) is adopted instead of conventional incandescent lamps for an amblyopia treatment system and seven training methods for rectifying amblyopia are incorporated so as for achieving an integrated therapy. The LED light source is designed to provide uniform illumination, adjustable light intensity and alterable colors. Experimental tests indicate that the LED light source operates steadily and fulfills the technical demand of amblyopia treatment.

  20. Head-mounted LED for optogenetic experiments of freely-behaving animal

    NASA Astrophysics Data System (ADS)

    Kwon, Ki Yong; Gnade, Andrew G.; Rush, Alexander D.; Patten, Craig D.

    2016-03-01

    Recent developments in optogenetics have demonstrated the ability to target specific types of neurons with sub-millisecond temporal precision via direct optical stimulation of genetically modified neurons in the brain. In most applications, the beam of a laser is coupled to an optical fiber, which guides and delivers the optical power to the region of interest. Light emitting diodes (LEDs) are an alternative light source for optogenetics and they provide many advantages over a laser based system including cost, size, illumination stability, and fast modulation. Their compact size and low power consumption make LEDs suitable light sources for a wireless optogenetic stimulation system. However, the coupling efficiency of an LED's output light into an optical fiber is lower than a laser due to its noncollimated output light. In typical chronic optogenetic experiment, the output of the light source is transmitted to the brain through a patch cable and a fiber stub implant, and this configuration requires two fiber-to-fiber couplings. Attenuation within the patch cable is potential source of optical power loss. In this study, we report and characterize a recently developed light delivery method for freely-behaving animal experiments. We have developed a head-mounted light source that maximizes the coupling efficiency of an LED light source by eliminating the need for a fiber optic cable. This miniaturized LED is designed to couple directly to the fiber stub implant. Depending on the desired optical power output, the head-mounted LED can be controlled by either a tethered (high power) or battery-powered wireless (moderate power) controller. In the tethered system, the LED is controlled through 40 gauge micro coaxial cable which is thinner, more flexible, and more durable than a fiber optic cable. The battery-powered wireless system uses either infrared or radio frequency transmission to achieve real-time control. Optical, electrical, mechanical, and thermal

  1. Color digital lensless holographic microscopy: laser versus LED illumination.

    PubMed

    Garcia-Sucerquia, Jorge

    2016-08-20

    A comparison of the performance of color digital lensless holographic microscopy (CDLHM) as utilized for illumination of RGB lasers or a super-bright white-light LED with a set of spectral filters is presented. As the use of lasers in CDLHM conceals the possibility of having a compact, lightweight, portable, and low cost microscope, and additionally the limited available laser radiation wavelengths limit a real multispectral imaging microscope, here we present the use of super-bright white-light LED and spectral filters for illuminating the sample. The performance of RGB laser-CDLHM and LED-CDLHM is evaluated on imaging a section of the head of a Drosophila melanogaster fly. This comparison shows that there is trade-off between the spatial resolution of the microscope and the light sources utilized, which can be understood with regard to the coherence properties of the illuminating light. Despite the smaller spatial coherence features of LED-CDLHM in comparison with laser-CDLHM, the former shows promise as a portable RGB digital lensless holographic microscope that could be extended to other wavelengths by the use of different spectral filters.

  2. LED photochemotherapy against Staphylococcus aureus: an in vitro study

    NASA Astrophysics Data System (ADS)

    de Oliveira, Susana C. P. S.; Monteiro, Juliana S. C.; Pires-Santos, Gustavo M.; Sampaio, Fernando José Pires; Soares, Luiz Guilherme P.; Soares, Amanda P.; Pinheiro, Antônio L. B.

    2018-02-01

    Bacterial resistance to antibiotics is reality and need for alternative treatments is urgent. The aim of this work was to evaluate, in vitro, the effect of LED photochemotherapy on Staphylococcus aureus (ATCC 23529) using 25 μg / mL of phenothiazine compound combined with LED light (λ632 +/- 2ηm) using 12 J/cm2 energy density. The experiments were carried out in triplicate and the samples were divided into groups: Control, Irradiated (treated only with light), Photosensitizer (treated only in the presence of the dye), LED-Photochemotherapy (treatment with light associated with dye). Counts of the colony forming units and the data obtained were statistically analyzed (ANOVA, Tukey's test, p<0.05). The present study demonstrated that the efficacy of LED-Photochemotherapy as the use of 25 μg/mL x 12 J/cm2 caused 91.57 % of inhibition of bacterial growth. It is concluded that using energy density of 12 J/cm2 associated to 25 μg/mL caused high in vitro inhibition of S. aureus.

  3. Driver-initiated distractions: examining strategic adaptation for in-vehicle task initiation.

    PubMed

    Horrey, William J; Lesch, Mary F

    2009-01-01

    Today, drivers are faced with many in-vehicle activities that are potentially distracting. In many cases, they are not passive recipients of these tasks; rather, drivers decide whether or not (or how) to perform them. In this study, we examined whether drivers, given knowledge of the upcoming road demands, would strategically delay performing in-vehicle activities until demands were reduced. Twenty drivers drove an instrumented van around a closed track that was divided into sections of varying demands and difficulty. Drivers were asked to perform one of four in-vehicle tasks (e.g., phone conversation; read a text message; find an address; pick up an object on the floor); however, they were free to decide when to initiate these tasks, provided they finish them before a given deadline. Although drivers were fully aware of the relative demands of the road, they did not tend to strategically postpone tasks--a finding that was consistent across the different tasks (p >.05). Rather, drivers tended to initiate tasks regardless of the current driving conditions. This strategy frequently led to driving errors. Given the control that drivers have over many in-vehicle distractions, interventions that focus on strategic decisions and planning may have merit.

  4. Effectiveness of nurse-led cardiac clinics in adult patients with a diagnosis of coronary heart disease.

    PubMed

    Page, Tamara; Lockwood, Craig; Conroy-Hiller, Tiffany

    2005-02-01

    Background  Coronary heart disease is the major cause of illness and death in Western countries and this is likely to increase as the average age of the population rises. Consumers with established coronary heart disease are at the highest risk of experiencing further coronary events. Lifestyle measures can contribute significantly to a reduction in cardiovascular mortality in established coronary heart disease. Improved management of cardiac risk factors by providing education and referrals as required has been suggested as one way of maintaining quality care in patients with established coronary heart disease. There is a need to ascertain whether or not nurse-led clinics would be an effective adjunct for patients with coronary heart disease to supplement general practitioner advice and care. Objectives  The objective of this review was to present the best available evidence related to nurse-led cardiac clinics. Inclusion criteria  This review considered any randomised controlled trials that evaluated cardiac nurse-led clinics. In the absence of randomised controlled trials, other research designs such as non-randomised controlled trials and before and after studies were considered for inclusion. Participants were adults (18 years and older) with new or existing coronary heart disease. The interventions of interest to the review included education, assessment, consultation, referral and administrative structures. Outcomes measured included adverse event rates, readmissions, admissions, clinical and cost effectiveness, consumer satisfaction and compliance with therapy. Results  Based on the search terms used, 80 papers were initially identified and reviewed for inclusion; full reports of 24 of these papers were retrieved. There were no papers included that addressed cost effectiveness or adverse events; and none addressed the outcome of referrals. A critical appraisal of the 24 remaining papers identified a total of six randomised controlled trials that

  5. LED deep UV source for charge management of gravitational reference sensors

    NASA Astrophysics Data System (ADS)

    Sun, Ke-Xun; Allard, Brett; Buchman, Saps; Williams, Scott; Byer, Robert L.

    2006-04-01

    Proof mass electrical charge management is an important functionality for the ST-7-LTP technology demonstration flight and for LISA. Photoemission for charge control is accomplished by using deep ultraviolet (UV) light to excite photoelectron emission from an Au alloy. The conventional UV source is a mercury vapour lamp. We propose and demonstrate charge management using a deep UV light emitting diode (LED) source. We have acquired selected AlGaN UV LEDs, characterized their performance and successfully used them to realize charge management. The UV LEDs emit at a 257 nm central wavelength with a bandwidth of ~12 nm. The UV power for a free-space LED is ~120 µW, and after fibre coupling is ~16 µW, more than sufficient for LISA applications. We have directly observed the LED UV light-induced photocurrent response from an Au photocathode and an Au-coated GRS/ST-7 proof mass. We demonstrated fast switching of UV LEDs and associated fast changes in photocurrent. This allows modulation and continuous discharge to meet stringent LISA disturbance reduction requirements. We propose and demonstrate AC charge management outside the gravitational wave signal band. Further, the megahertz bandwidth for UV LED switching allows for up to six orders of magnitude dynamic power range and a number of novel modes of operations. The UV LED based charge management system offers the advantages of small-size, lightweight, fibre-coupled operation with very low power consumption. Presented at 'Amaldi6', Poster 73, Space Detector, 6th Edoardo Almadi Conference on Gravitational Waves, 20-24 June 2005.

  6. Microbial UV fluence-response assessment using a novel UV-LED collimated beam system.

    PubMed

    Bowker, Colleen; Sain, Amanda; Shatalov, Max; Ducoste, Joel

    2011-02-01

    A research study has been performed to determine the ultraviolet (UV) fluence-response of several target non-pathogenic microorganisms to UV light emitting diodes (UV-LEDs) by performing collimated beam tests. UV-LEDs do not contain toxic mercury, offer design flexibility due to their small size, and have a longer operational life than mercury lamps. Comsol Multiphysics was utilized to create an optimal UV-LED collimated beam design based on number and spacing of UV-LEDs and distance of the sample from the light source while minimizing the overall cost. The optimized UV-LED collimated beam apparatus and a low-pressure mercury lamp collimated beam apparatus were used to determine the UV fluence-response of three surrogate microorganisms (Escherichia coli, MS-2, T7) to 255 nm UV-LEDs, 275 nm UV-LEDs, and 254 nm low-pressure mercury lamps. Irradiation by low-pressure mercury lamps produced greater E. coli and MS-2 inactivation than 255 nm and 275 nm UV-LEDs and similar T7 inactivation to irradiation by 275 nm UV-LEDs. The 275 nm UV-LEDs produced more efficient T7 and E. coli inactivation than 255 nm UV-LEDs while both 255 nm and 275 nm UV-LEDs produced comparable microbial inactivation for MS-2. Differences may have been caused by a departure from the time-dose reciprocity law due to microbial repair mechanisms. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. The Influence of Different Recycling Scenarios on the Mechanical Design of an LED Weatherproof Light Fitting

    PubMed Central

    Camañes, Víctor; Elduque, Daniel; Javierre, Carlos; Fernández, Ángel

    2014-01-01

    This paper analyzes the high relevance of material selection for the sustainable development of an LED weatherproof light fitting. The research reveals how this choice modifies current and future end of life scenarios and can reduce the overall environmental impact. This life cycle assessment has been carried out with Ecotool, a software program especially developed for designers to assess the environmental performance of their designs at the same time that they are working on them. Results show that special attention can be put on the recycling and reusing of the product from the initial stages of development. PMID:28788160

  8. The Influence of Different Recycling Scenarios on the Mechanical Design of an LED Weatherproof Light Fitting.

    PubMed

    Camañes, Víctor; Elduque, Daniel; Javierre, Carlos; Fernández, Ángel

    2014-08-11

    This paper analyzes the high relevance of material selection for the sustainable development of an LED weatherproof light fitting. The research reveals how this choice modifies current and future end of life scenarios and can reduce the overall environmental impact. This life cycle assessment has been carried out with Ecotool, a software program especially developed for designers to assess the environmental performance of their designs at the same time that they are working on them. Results show that special attention can be put on the recycling and reusing of the product from the initial stages of development.

  9. LEDs for solid state lighting and other emerging applications: status, trends, and challenges

    NASA Astrophysics Data System (ADS)

    Craford, M. George

    2005-09-01

    LEDs have been commercially available since the 1960's, but in recent years there have been remarkable improvements in performance. These technology developments have enabled the use of LEDs in a variety of colored and white lighting applications. Colored LEDs have already become the technology of choice for traffic signals, much of interior and exterior vehicle lighting, signage of various types often as a replacement for neon, and other areas. LEDs are expected to become the dominant technology for most colored lighting applications. LEDs are beginning to penetrate white lighting markets such as flashlights and localized task lighting. With further improvement LEDs have the potential to become an important technology for large area general illumination. White LED products already have performance of over 30 lumens/watt which is nearly 3x better than incandescents. White LEDs with outputs of more than 100 lumens are already available commercially, and higher power devices can be expected in the near future. LEDs can be used as point sources, or can be used with light guides of various types to provide distributed illumination. Developments that will need to occur for LEDs to be viable for large area general illumination are discussed.

  10. Integrating Family as a Discipline by Providing Parent Led Curricula: Impact on LEND Trainees' Leadership Competency.

    PubMed

    Keisling, Bruce L; Bishop, Elizabeth A; Roth, Jenness M

    2017-05-01

    Background While the MCH Leadership Competencies and family as a discipline have been required elements of Leadership Education in Neurodevelopmental and related Disabilities (LEND) programs for over a decade, little research has been published on the efficacy of either programmatic component in the development of the next generation of leaders who can advocate and care for Maternal and Child Health (MCH) populations. Objective To test the effectiveness of integrating the family discipline through implementation of parent led curricula on trainees' content knowledge, skills, and leadership development in family-centered care, according to the MCH Leadership Competencies. Methods One hundred and two long-term (≥ 300 h) LEND trainees completed a clinical and leadership training program which featured intensive parent led curricula supported by a full-time family faculty member. Trainees rated themselves on the five Basic and Advanced skill items that comprise MCH Leadership Competency 8: Family-centered Care at the beginning and conclusion of their LEND traineeship. Results When compared to their initial scores, trainees rated themselves significantly higher across all family-centered leadership competency items at the completion of their LEND traineeship. Conclusions The intentional engagement of a full-time family faculty member and parent led curricula that include didactic and experiential components are associated with greater identification and adoption by trainees of family-centered attitudes, skills, and practices. However, the use of the MCH Leadership Competencies as a quantifiable measure of program evaluation, particularly leadership development, is limited.

  11. The Initial Training of Geography Teachers at the University of Porto: Model and Training, Practices and Representations

    ERIC Educational Resources Information Center

    Martins, Felisbela

    2015-01-01

    Since 2008, the initial training of Geography teachers in Portugal was combined with the initial training of History teachers. This forced union has led to implications in the practices and teaching of geography. This paper intends to explore the thoughts and actions of the student teachers at the Faculty of Arts and Humanities, University of…

  12. Surgical operation using lighting goggle composed of white LED arrays

    NASA Astrophysics Data System (ADS)

    Shimada, Junichi; Kawakami, Yoichi; Fujita, Shigeo

    2001-12-01

    Everywhere in the world, the highest quality and quantity of lighting is required during the surgical operations. However, the surgical approach has had many types and various angles, common ceiling surgical halogen lighting system cannot provide an adequate amount of beams because the surgeons' heads hinder the illuminations from reaching the operation field. Here, we newly design surgical lighting system composed of white LEDs equipped on both sides of goggles, which controls the lighting beams to the gazing point. With this system, it is just needed for surgeons to wear light plastic goggles with high quality LEDs made by Nichia. In fact, we have succeeded in the first internal shunt operation in the left forearm using the surgical LED lighting system on 11th Sept 2000. The electrical power for the system was supplied from lithium-ion battery for 2 hours. Since the white LEDs used were composed of InGaN-blue-emitters and YAG-yellow-phosphors, the color rendering property was not sufficient in the reddish colors. Therefore, in the next approach, it is very important to develop the spectral distribution of white LED to render inherent color of raw flesh such as skin, blood, fat tissue and internal organs. To improve the color rendering in red colors, some adjustments should be given in the fluorescents layers. Design of goggle is also very important for cutting into the real practical market of white LEDs.

  13. The Development and Initial Evaluation of the Human Readiness Level Framework

    DTIC Science & Technology

    2010-06-01

    View ICD Initial Capabilities Document ICW Interactive Course Ware ILE Interactive Learning Environment ILT Instructor Led Training IOC...Programmatic Environmental Safety and Health Evaluation PHA Preliminary Hazard Analysis PHL Preliminary Hazard List xiv PM Program Manager PQS...Occupational Health SOW Statement of Work SRD System Requirements Document SPS System Performance Specification SRR System Requirements Review SVR

  14. EarthCube - A Community-led, Interdisciplinary Collaboration for Geoscience Cyberinfrastructure

    NASA Astrophysics Data System (ADS)

    Allison, M. L.; Keane, C. M.; Robinson, E.

    2015-12-01

    The EarthCube Test Enterprise Governance Project completed its initial two-year long process to engage the community and test a demonstration governing organization with the goal of facilitating a community-led process on designing and developing a geoscience cyberinfrastructure. Conclusions are that EarthCube is viable, has engaged a broad spectrum of end-users and contributors, and has begun to foster a sense of urgency around the importance of open and shared data. Levels of trust among participants are growing. At the same time, the active participants in EarthCube represent a very small sub-set of the larger population of geoscientists. Results from Stage I of this project have impacted NSF decisions on the direction of the EarthCube program. The overall tone of EarthCube events has had a constructive, problem-solving orientation. The technical and organizational elements of EarthCube are poised to support a functional infrastructure for the geosciences community. The process for establishing shared technological standards has notable progress but there is a continuing need to expand technological and cultural alignment. Increasing emphasis is being given to the interdependencies among EarthCube funded projects. The newly developed EarthCube Technology Plan highlights important progress in this area by five working groups focusing on: 1. Use cases; 2. Funded project gap analysis; 3. Testbed development; 4. Standards; and 5. Architecture. There is ample justification to continue running a community-led governance framework that facilitates agreement on a system architecture, guides EarthCube activities, and plays an increasing role in making the EarthCube vision of cyberinfrastructure for the geosciences operational. There is widespread community expectation for support of a multiyear EarthCube governing effort to put into practice the science, technical, and organizational plans that have and are continuing to emerge.

  15. Portfolios for determining initial licensure competency.

    PubMed

    Chambers, David W

    2004-02-01

    Because attempts to improve initial licensure examinations have not been grounded in measurement theory, partial and inadequate remedies have led to a cycle of refutations, defenses and political polarization. The author reviewed the psychometric literature, focusing on high-stakes professional decisions. Editorials in the dental literature and position papers of involved organizations often use words from this literature without incorporating its fundamental concepts. The reliability of one-shot initial licensure examinations is estimated to be approximately r = .40, which is a value well under the standard for such tests in other professions. Validity has not been investigated rigorously, but the one-shot format and proposals to remove live patients certainly would reduce validity. The use of portfolios--a small number of evaluations in several realistic task domains--is a viable means of achieving psychometric standards for initial licensure decisions. Boards are charged with making valid and reliable licensure decisions, not with conducting examinations. At a minimum, they must define the competencies of beginning practitioners and establish the psychometric criteria for their decisions (neither of which are done currently). Gathering data then can be delegated to whoever is best qualified to meet these standards.

  16. The High-efficiency LED Driver for Visible Light Communication Applications.

    PubMed

    Gong, Cihun-Siyong Alex; Lee, Yu-Chen; Lai, Jyun-Liang; Yu, Chueh-Hao; Huang, Li Ren; Yang, Chia-Yen

    2016-08-08

    This paper presents a LED driver for VLC. The main purpose is to solve the low data rate problem used to be in switching type LED driver. The GaN power device is proposed to replace the traditional silicon power device of switching LED driver for the purpose of increasing switching frequency of converter, thereby increasing the bandwidth of data transmission. To achieve high efficiency, the diode-connected GaN power transistor is utilized to replace the traditional ultrafast recovery diode used to be in switching type LED driver. This work has been experimentally evaluated on 350-mA output current. The results demonstrate that it supports the data of PWM dimming level encoded in the PPM scheme for VLC application. The experimental results also show that system's efficiency of 80.8% can be achieved at 1-Mb/s data rate.

  17. Removal of dibutyl phthalate from aqueous environments using a nanophotocatalytic Fe, Ag-ZnO/VIS-LED system: modeling and optimization.

    PubMed

    Akbari-Adergani, B; Saghi, M H; Eslami, A; Mohseni-Bandpei, A; Rabbani, M

    2018-06-01

    An (Fe, Ag) co-doped ZnO nanostructure was synthesized by a simple chemical co-precipitation method and used for the degradation of dibutyl phthalate (DBP) in aqueous solution under visible light-emitting diode (LED) irradiation. (Fe, Ag) co-doped ZnO nanorods were characterized by powder X-ray diffraction, Fourier transform infrared spectroscopy, UV-VIS diffuse reflectance spectroscopy, elemental mapping, Field emission scanning electron microscopy, transmission electron microscope and Brunauer-Emmett-Teller surface area analysis. A Central Composite Design was used to optimize the reaction parameters for the removal of DBP by the (Fe, Ag) co-doped ZnO nanorods. The four main reaction parameters optimized in this study were the following: pH, time of radiation, concentration of the nanorods and initial DBP concentration. The interaction between the four parameters was studied and modeled using the Design Expert 10 software. A maximum reduction of 95% of DBP was achieved at a pH of 3, a photocatalyst concentration of 150 mg L -1 and a DBP initial DBP concentration of 15 mg L -1 . The results showed that the (Fe, Ag) co-doped ZnO nanorods under low power LED irradiation can be used as an effective photocatalyst for the removal of DBP from aqueous solutions.

  18. RGB LED with smart control in the backlight and lighting

    NASA Astrophysics Data System (ADS)

    Ku, Johnson C. S.; Lee, C. J.

    2008-02-01

    To improve the LED (Light Emitting Diode) efficacy is the major consideration when the backlight and lighting system are implemented. An important source of poor efficacy come from the chip process or heat dissipation. White LED used blue chip with phosphor is the current solution and inadequate for the tunable color temperature system. The use of RGB (Red, Green and Blue) LED with smart control is presented in this study. The resulting coupled optical and thermal shows the better performance when it is synthesized in conjunction with a degree of color mixing technology.

  19. Modeling Ultraviolet (UV) Light Emitting Diode (LED) Energy Propagation in Reactor Vessels

    DTIC Science & Technology

    2014-03-27

    21 Table 4: UV Mercury Lamps , UV LED Bulbs, and Visible LED Bulb Advantages and Disadvantages...over low pressure mercury lamps include smaller size, minimal start up time, and no hazardous material. Projections show UV LEDs will follow similar

  20. Light emitting diodes (LED): applications in forest and native plant nurseries

    Treesearch

    Thomas D. Landis; Jeremiah R. Pinto; R. Kasten Dumroese

    2013-01-01

    It was quotes like this that made us want to learn more about light emitting diodes (LED). Other than knowing that LEDs were the latest innovation in artificial lighting, we knew that we had a lot to learn. So we started by reviewing some of the basics. The following review is a brief synopsis of how light affects plants and some discussion about LED lighting. If you...

  1. Solar spectrum matching with white OLED and monochromatic LEDs.

    PubMed

    Yu, Hui-Yuan; Cao, Guan-Ying; Zhang, Jing-Hui; Yang, Yi; Sun, Wen-Liang; Wang, Li-Ping; Zou, Nian-Yu

    2018-04-01

    In this paper, the solar spectrum matching in the visible range of 380-780 nm with white organic light-emitting diode (OLED) and monochromatic light-emitting diodes (LEDs) is investigated. The correlation index ( R 2 ) is used to evaluate the difference between the matching spectrum and the solar spectrum. The optimal combination is obtained by the least squares method. We also perform subtraction experiments to find the optimal combination. We utilize a common white OLED device design and just change the species of monochromatic LEDs used. We report and evaluate different degrees of matching effects. The results show that the correlation index of the best combination can reach 94.09% with white OLED and 36 monochromatic LEDs. We define three levels of performance as an evaluation system in accordance with the matching effect. The level is excellent with an R 2 above 90.14%. The good level is from 86.65% to 58.28%. From 42.08% to 33.06% is the reasonable level. Compared with other methods, using white OLED combined with monochromatic LEDs achieves the best solar spectrum matching effect. The results can be applied to different requirements of engineering practice.

  2. Universal Surface-initiated Polymerization of Antifouling Zwitterionic Brushes Using A Mussel-Mimetic Peptide Initiator

    PubMed Central

    Kuang, Jinghao; Messersmith, Phillip B.

    2012-01-01

    We report a universal method for the surface-initated polymerization (SIP) of a antifouling polymer brush on various classes of surfaces, including noble metals, metal oxides and inert polymers. Inspired by the versatility of mussel adhesive proteins, we synthesized a novel bifunctional tripeptide bromide (BrYKY) which combines an atom transfer radical polymerization (ATRP) initiating alkyl bromide with l-3,4-dihydroxyphenylalanine (DOPA) and lysine. Simple dip-coating of substrates with variable wetting properties and compositions, including Teflon®, in a BrYKY solution at pH 8.5 led to formation of a thin film of cross-linked BrYKY. Subsequently, we showed that the BrYKY layer initiated the ATRP of a zwitterionic monomer, sulfobetaine methacrylate (SBMA) on all substrates, resulting in high density antifouling pSBMA brushes. Both BrYKY deposition and pSBMA grafting were unambiguously confirmed by ellipsometry, X-ray photoelectron spectroscopy and goniometry. All substrates that were coated with BrYKY/pSBMA dramatically reduced bacterial adhesion for 24 h and also resisted mammalian cell adhesion for at least 4 months, demonstrating the long-term stability of the BrYKY anchoring and antifouling properties of pSBMA. The use of BrYKY as a primer and polymerization initiator has the potential to be widely employed in surface grafted polymer brush modifications for biomedical and other applications. PMID:22506651

  3. LED roadway lighting, volume 2 : field evaluations and software comparisons.

    DOT National Transportation Integrated Search

    2012-10-01

    The use of light-emitting diodes (LEDs) for roadway lighting can potentially save energy costs and reduce the frequency of maintenance. The objective of this study is to explore the current state of the art in LED roadway lighting technology. Three s...

  4. CMOS-compatible plenoptic detector for LED lighting applications.

    PubMed

    Neumann, Alexander; Ghasemi, Javad; Nezhadbadeh, Shima; Nie, Xiangyu; Zarkesh-Ha, Payman; Brueck, S R J

    2015-09-07

    LED lighting systems with large color gamuts, with multiple LEDs spanning the visible spectrum, offer the potential of increased lighting efficiency, improved human health and productivity, and visible light communications addressing the explosive growth in wireless communications. The control of this "smart lighting system" requires a silicon-integrated-circuit-compatible, visible, plenoptic (angle and wavelength) detector. A detector element, based on an offset-grating-coupled dielectric waveguide structure and a silicon photodetector, is demonstrated with an angular resolution of less than 1° and a wavelength resolution of less than 5 nm.

  5. The High-efficiency LED Driver for Visible Light Communication Applications

    PubMed Central

    Gong, Cihun-Siyong Alex; Lee, Yu-Chen; Lai, Jyun-Liang; Yu, Chueh-Hao; Huang, Li Ren; Yang, Chia-Yen

    2016-01-01

    This paper presents a LED driver for VLC. The main purpose is to solve the low data rate problem used to be in switching type LED driver. The GaN power device is proposed to replace the traditional silicon power device of switching LED driver for the purpose of increasing switching frequency of converter, thereby increasing the bandwidth of data transmission. To achieve high efficiency, the diode-connected GaN power transistor is utilized to replace the traditional ultrafast recovery diode used to be in switching type LED driver. This work has been experimentally evaluated on 350-mA output current. The results demonstrate that it supports the data of PWM dimming level encoded in the PPM scheme for VLC application. The experimental results also show that system’s efficiency of 80.8% can be achieved at 1-Mb/s data rate. PMID:27498921

  6. Color Maintenance of LEDs in Laboratory and Field Applications

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Royer, Michael P.; Tuttle, Ralph; Rosenfeld, Scott M.

    Synopsis: To date, consideration for parametric failure of LED products has largely been focused on lumen maintenance. However, color shift is a cause of early failure for some products, and is especially important to consider in certain applications, like museums, where visual appearance is critical. Example data collected by the GATEWAY program for LED lamps installed in museums shows that many have changed color beyond a reasonable tolerance well before their rated lifetime was reached, necessitating replacement. Similar data collected by the CALiPER program between 2008 and 2010 reveals that many early products shifted beyond acceptable tolerances in as littlemore » as a few thousand hours. In contrast, data from the L Prize program illustrates that commercially available LED products can have exemplary color stability that is unmatched by traditional light sources. Beyond presenting data from the aforementioned DOE programs, this report discusses the metrics used for communicating color shift—namely MacAdam ellipses and Δu'v'—as well as providing guidance for end users on how to monitor color shift and what to look for in manufacturer warranties. Also included are descriptions of the physical changes that have been documented as leading to color shift in some example types of LED packages. As with complete products, the data presented herein for LED packages shows that a wide variety of products are available; in order for specifiers and consumers to make educated choices, more detailed and standardized information should be made available.« less

  7. Glare effect for three types of street lamps based on White LEDs

    NASA Astrophysics Data System (ADS)

    Sun, Ching-Cherng; Jiang, Chong-Jhih; Chen, Yi-Chun; Yang, Tsung-Hsun

    2014-05-01

    This study is aimed to assess the glare effect from LED-based street lamps with three general optical designs, which are cluster LEDs with a single lens, a LED array accompany with a lens array, and a tilted LED array, respectively. Observation conditions were simulated based on various locations and viewing axes. Equivalent luminance calculations were used to reveal the glare levels of the three designs. The age effect for the calculated equivalent luminance was also examined for human eyes of people at the age of 40 or 60. The results demonstrate that among the three design types, a LED array accompany with a lens array causes relatively smaller glare for most viewing conditions.

  8. Non-imaging Optics of multi-LED light source for hyperspectral imaging

    NASA Astrophysics Data System (ADS)

    Islam, Kashif; Gosnell, Martin E.; Ploschner, Martin; Anwer, Ayad G.; Goldys, Ewa M.

    2016-12-01

    The main objective of our work was to design a light source which should be capable to collect and illuminate light of LEDs at the smaller aperture of cone (9mm) which could be either coupled with secondary optics of a microscope or utilized independently for hyperspectral studies. Optimized performance of cone was assessed for different substrates (diffused glass silica, Alumina, Zerodur glass, acrylic plastic) and coating surfaces (white diffused, flat white paint, standard mirror) using a simulation software. The parameters optimized for truncated cone include slanting length and Top Major R (Larger diameter of cone) which were also varied from 10 to 350 mm and 10 to 80 mm respectively. In order to see affect of LED positions on cone efficiency, the positions of LED were varied from central axis to off-axis. Similarly, interLED distance was varied from 2 mm to 6 mm to reckon its effect on the performance of cone. The optimized Slant length (80 mm) and Top Major R (50 mm) were determined for substrates (glass zerodur or acrylic plastic) and coating surface (standard mirror). The output profile of truncated source was found non uniform, which is a typical presentation of non imaging optics problem. The maximum efficiency of cone has been found for LED at the centre and it was found decreasing as LED moves away from the central axis. Moreover, shorter the interLED distance, better is the performance of cone. The primary optics of cone shaped light source is capable to lit visible and UV LEDs in practical design. The optimum parameters obtained through simulations could be implemented in the fabrication procedure if the reflectance of source would have been maintained upto finish level of a standard mirror.

  9. Construction of an array of LEDs coupled to a concentrator for phototherapy

    NASA Astrophysics Data System (ADS)

    Almeida, Joana; Liang, Dawei

    2011-07-01

    The use of LED devices for phototherapy has been expanding in the last decade. This technology provides a safer emission spectrum in large target tissue areas when compared to laser emissions. For enhancing the phototherapeutic effects of red light emitted by LEDs, a simple optical concentrator capable of efficient light concentration and homogenization was developed. The LEDs wavelength of 660 nm is coincident with an absorption peak of the mitochondrial photoreceptor molecule cytochrome c oxidase. The prototype was optimized by non-sequential ray-tracing software ZEMAX, attaining both excellent light uniformity and 50mW/cm2 irradiance at the concentrator output end. Heat emanated from the LEDs source is effectively dissipated by the side walls of the concentrator, ensuring a nearly constant temperature environment for tissue treatment. The prototype was tested on cutaneous hyperpigmented marks caused by cupping in two healthy volunteers. Marks were irradiated by LEDs radiations with or without the use of concentrator respectively. Equal exposure durations and light fluences were tested. The use of the concentrator-coupled LEDs source revealed an activation of blood movement immediately after LEDs exposure, an effect not attainable by the LEDs source without the concentrator even at extended exposure time. Promising futures for the treatment of inflammation, tissue repair and skin rejuvenation could be expected by adopting this simple technique.

  10. Lumen degradation analysis of LED lamps based on the subsystem isolation method.

    PubMed

    Ke, Hong-Liang; Hao, Jian; Tu, Jian-Hui; Miao, Pei-Xian; Wang, Chao-Quan; Cui, Jing-Zhong; Sun, Qiang; Sun, Ren-Tao

    2018-02-01

    The lumen degradation of LED lamps undergoing an accelerated aging test is investigated. The entire LED lamp is divided into three subsystems, namely, driver, lampshade, and LED light source. The parameters of output power [Watts (W)], transmittance (%), and lumen flux (lm) are adopted in the analysis of the degradation of the driver, lampshade, and LED light source, respectively. Two groups of LED lamps are aged under the ambient temperatures of 25°C and 85°C, respectively, with the aging time of 2000 h. The lumen degradation of the lamps is from 3.8% to 4.9% for the group under a temperature of 25°C and from 10.6% to 12.7% for the group under a temperature of 85°C. The LED light source is the most aggressive part of the three subsystems, which accounts for 70.5% of the lumen degradation of the LED lamp on average. The lampshade is the second degradation source, which causes 21.5% of the total amount on average. The driver is the third degradation source, which causes 6.5% under 25°C and 2.8% under 85°C of the total amount on average.

  11. How nurse-led practices perceive implementation of the patient-centered medical home.

    PubMed

    Frasso, Rosemary; Golinkoff, A; Klusaritz, Heather; Kellom, Katherine; Kollar-McArthur, Helen; Miller-Day, Michelle; Gabbay, Robert; Cronholm, Peter F

    2017-04-01

    The Affordable Care Act (ACA) promotes the Patient-Centered Medical Home (PCMH) model as a way to improve healthcare quality, the patient experience, and has identified nurse-led primary care as a mechanism meeting the increasing demand for quality primary care. The purpose of this study was to investigate the implementation of a PCMH model in nurse-led primary care practices and to identify facilitators and barriers to the implementation of this model. Data were collected through in-depth interviews with providers and staff in nurse-led practices. These data suggest two categories of processes that facilitate the integration of PCMH in the nurse-led practice setting: patient-oriented facilitators and organizational facilitators. In addition, a number of barriers were identified to implementing the PCMH model. Overall, these practices creatively engaged in the transformation process by structuring themselves as a complex adaptive system and building upon the core principles of nurse-led care. Since the core principles of nurse-led care map onto many of the same principles of the PCMH model, this study discusses the possibility that nurse-led practices may experience fewer barriers when transitioning into PCMHs. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. Where Creativity Meets Technology: A Library-Led, Multi-Disciplinary Online Showcase for Artworks, Creative Writings, and Movies Displayed with 3D and HTML5 Technology

    ERIC Educational Resources Information Center

    Wong, Shun Han Rebekah

    2015-01-01

    This article introduces the Hong Kong Baptist University's Heritage project (http://heritage.lib.hkbu.edu.hk/), a multi-disciplinary online showcase for curriculum-related creative outputs that were produced by faculty and students of the university. Initiated and led by the University Library, this project was a collaborative effort with six…

  13. Baby-Led Introduction to SolidS (BLISS) study: a randomised controlled trial of a baby-led approach to complementary feeding.

    PubMed

    Daniels, Lisa; Heath, Anne-Louise M; Williams, Sheila M; Cameron, Sonya L; Fleming, Elizabeth A; Taylor, Barry J; Wheeler, Ben J; Gibson, Rosalind S; Taylor, Rachael W

    2015-11-12

    In 2002, the World Health Organization recommended that the age for starting complementary feeding should be changed from 4 to 6 months of age to 6 months. Although this change in age has generated substantial debate, surprisingly little attention has been paid to whether advice on how to introduce complementary foods should also be changed. It has been proposed that by 6 months of age most infants will have developed sufficient motor skills to be able to feed themselves rather than needing to be spoon-fed by an adult. This has the potential to predispose infants to better growth by fostering better energy self-regulation, however no randomised controlled trials have been conducted to determine the benefits and risks of such a "baby-led" approach to complementary feeding. This is of particular interest given the widespread use of "Baby-Led Weaning" by parents internationally. The Baby-Led Introduction to SolidS (BLISS) study aims to assess the efficacy and acceptability of a modified version of Baby-Led Weaning that has been altered to address potential concerns with iron status, choking and growth faltering. The BLISS study will recruit 200 families from Dunedin, New Zealand, who book into the region's only maternity hospital. Parents will be randomised into an intervention (BLISS) or control group for a 12-month intervention with further follow-up at 24 months of age. Both groups will receive the standard Well Child care provided to all parents in New Zealand. The intervention group will receive additional parent contacts (n = 8) for support and education on BLISS from before birth to 12 months of age. Outcomes of interest include body mass index at 12 months of age (primary outcome), energy self-regulation, iron and zinc intake and status, diet quality, choking, growth faltering and acceptability to parents. This study is expected to provide insight into the feasibility of a baby-led approach to complementary feeding and the extent to which this method of

  14. A three-channel LED driver with single line transportation technique

    NASA Astrophysics Data System (ADS)

    Yu, Caideng; Du, Yiying; Jiang, Qiao; Zhou, Yun; Lv, Jian

    2012-10-01

    Designed a three-channel LED driver, realized the single-wire transmission of cascade signal between the drive IC of LED. Including the MCU digital interface, date register, clock synchronization, PWM grayscale adjustment circuit, as well as high voltage driver circuit for LED, etc… The driver control LED displaying 256 gray. Chip will generate synchronous sampling clock signals according to the received serial signals, when 24 bits dates have been received, the output pin begins to transport the dates followed-up which are automotive shaped to the input of the next chip. When the date receiving becomes low level that represent RESET, the red, green and blue channels will export different signals based on different input dates. Through the external MCU, it is realized the Separate luminance, and by connecting chips in series it achieved the control of outdoor big screen' colorful display. The automatic shaping forward technique makes the number of chips cascading immune to the limitations of signal transmission, but only limited by the refresh speed.

  15. Single-exposure quantitative phase imaging in color-coded LED microscopy.

    PubMed

    Lee, Wonchan; Jung, Daeseong; Ryu, Suho; Joo, Chulmin

    2017-04-03

    We demonstrate single-shot quantitative phase imaging (QPI) in a platform of color-coded LED microscopy (cLEDscope). The light source in a conventional microscope is replaced by a circular LED pattern that is trisected into subregions with equal area, assigned to red, green, and blue colors. Image acquisition with a color image sensor and subsequent computation based on weak object transfer functions allow for the QPI of a transparent specimen. We also provide a correction method for color-leakage, which may be encountered in implementing our method with consumer-grade LEDs and image sensors. Most commercially available LEDs and image sensors do not provide spectrally isolated emissions and pixel responses, generating significant error in phase estimation in our method. We describe the correction scheme for this color-leakage issue, and demonstrate improved phase measurement accuracy. The computational model and single-exposure QPI capability of our method are presented by showing images of calibrated phase samples and cellular specimens.

  16. An Integrated Multilevel Converter with Sigma Delta Control for LED Lighting

    NASA Astrophysics Data System (ADS)

    Gerber, Daniel L.

    High brightness LEDs have become a mainstream lighting technology due to their efficiency, life span, and environmental benefits. As such, the lighting industry values LED drivers with low cost, small form factor, and long life span. Additional specifications that define a high quality LED driver are high efficiency, high power factor, wide-range dimming, minimal flicker, and a galvanically isolated output. The flyback LED driver is a popular topology that satisfies all these specifications, but it requires a bulky and costly flyback transformer. In addition, its passive methods for cancelling AC power ripple require electrolytic capacitors, which have been known to have life span issues. This dissertation details the design, construction, and verification of a novel LED driver that satisfies all the specifications. In addition, it does not require a flyback transformer or electrolytic capacitors, thus marking an improvement over the flyback driver on size, cost, and life span. This dissertation presents an integrated circuit (IC) LED driver, which features a pair of generalized multilevel converters that are controlled via sigma-delta modulation. The first is a multilevel rectifier responsible for power factor correction (PFC) and dimming. The PFC rectifier employs a second order sigma-delta loop to precisely control the input current harmonics and amplitude. The second is a bidirectional multilevel inverter used to cancel AC power ripple from the DC bus. This ripple-cancellation module transfers energy to and from a storage capacitor. It uses a first order sigma-delta loop with a preprogrammed waveform to swing the storage capacitor voltage. The system also contains an output stage that powers the LEDs with DC and provides for galvanic isolation. The output stage consists of an H-bridge stack that connects to the output through a small toroid transformer. The IC LED driver was simulated and prototyped on an ABCD silicon test chip. Testing and verification

  17. Light-Emitting Diode (LED) Traps Improve the Light-Trapping of Anopheline Mosquitoes.

    PubMed

    Costa-Neta, B M; da Silva, A A; Brito, J M; Moraes, J L P; Rebêlo, J M M; Silva, F S

    2017-11-07

    Numerous advantages over the standard incandescent lamp favor the use of light-emitting diodes (LEDs) as an alternative and inexpensive light source for sampling medically important insects in surveillance studies. Previously published studies examined the response of mosquitoes to different wavelengths, but data on anopheline mosquito LED attraction are limited. Center for Disease Control and Prevention-type light traps were modified by replacing the standard incandescent lamp with 5-mm LEDs, one emitting at 520 nm (green) and the other at 470 nm (blue). To test the influence of moon luminosity on LED catches, the experiments were conducted during the four lunar phases during each month of the study period. A total of 1,845 specimens representing eight anopheline species were collected. Anopheles (Nyssorhynchus) evansae (35.2%) was the most frequently collected, followed by An. (Nys.) triannulatus (21.9%), An. (Nys.) goeldii (12.9%), and An. (Nys.) argyritarsis (11.5%). The green LED was the most attractive light source, accounting for 43.3% of the individuals collected, followed by the blue (31.8%) and control (24.9%) lights. The LED traps were significantly more attractive than the control, independent of the lunar phase. Light trapping of anopheline mosquitoes was more efficient when the standard incandescent lamp was replaced with LEDs, regardless of the moon phase. The efficiency of LEDs improves light trapping results, and it is suggested that the use of LEDs as an attractant for anopheline mosquitoes should be taken into consideration when sampling anopheline mosquitoes. © The Authors 2017. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  18. Comparison of halogen, plasma and LED curing units.

    PubMed

    Nomoto, Rie; McCabe, John F; Hirano, Susumu

    2004-01-01

    This study evaluated the characteristics of two kinds of recently developed light-curing unit; plasma arc and blue light emitting diodes (LED), in comparison with a conventional tungsten-halogen light-curing unit. The light intensity and spectral distribution of light from these light-curing units, the temperature rise of the bovine enamel surface and the depth of cure of composites exposed to each unit were investigated. The light intensity and depth of cure were determined according to ISO standards. The spectral distributions of emitted light were measured using a spectro-radiometer. The temperature increase induced by irradiation was measured by using a thermocouple. Generally, light intensities in the range 400-515 nm emitted from the plasma arc were greater than those from other types. Light in the UV-A region was emitted from some plasma arc units. The required irradiation times were six to nine seconds for the plasma arc units and 40 to 60 seconds for the LED units to create a depth of cure equal to that produced by the tungsten-halogen light with 20 seconds of irradiation. The temperature increased by increasing the irradiation time for every light-curing unit. The temperature increases were 15 degrees C to 60 degrees C for plasma arc units, around 15 degrees C for a conventional halogen unit and under 10 degrees C for LED units. Both the plasma arc and LED units required longer irradiation times than those recommended by their respective manufacturers. Clinicians should be aware of potential thermal rise and UV-A hazard when using plasma arc units.

  19. Examining Young Recreational Male Soccer Players' Experience in Adult- and Peer-Led Structures.

    PubMed

    Imtiaz, Faizan; Hancock, David J; Côté, Jean

    2016-09-01

    Youth sport has the potential to be one of the healthiest and most beneficial activities in which children can partake. Participation in a combination of adult-led and peer-led sport structures appears to lead to favorable outcomes such as enhanced physical fitness, as well as social and emotional development. The purpose of the present study was to examine the subjective and objective experiences of 27 recreational male soccer players aged 10 to 12 years old (M = 10.11 years, SD = 0.32) across adult-led and peer-led sport structures. Direct video observation and experience-rating scales were utilized in an effort to shed light on the impact of adult-led and peer-led sport structures on the same athletes. In the adult-led structures, youth experienced high levels of effort and concentration while spending more time physically or mentally engaged. Meanwhile, youth experienced high rates of prosocial behaviors, sport-related communication, and general communication during the peer-led structures. The results of the present study indicate that rather than one approach being superior to the other, both adult- and peer-led sport structures have the potential to yield unique benefits toward children's positive experiences in sport.

  20. Coumarin-Based Oxime Esters: Photobleachable and Versatile Unimolecular Initiators for Acrylate and Thiol-Based Click Photopolymerization under Visible Light-Emitting Diode Light Irradiation.

    PubMed

    Li, Zhiquan; Zou, Xiucheng; Zhu, Guigang; Liu, Xiaoya; Liu, Ren

    2018-05-09

    Developing efficient unimolecular visible light-emitting diode (LED) light photoinitiators (PIs) with photobleaching capability, which are essential for various biomedical applications and photopolymerization of thick materials, remains a great challenge. Herein, we demonstrate the synthesis of a series of novel PIs, containing coumarin moieties as chromophores and oxime ester groups as initiation functionalities and explore their structure-activity relationship. The investigated oxime esters can effectively induce acrylates and thiol-based click photopolymerization under 450 nm visible LED light irradiation. The initiator O-3 exhibited excellent photobleaching capability and enabled photopolymerization of thick materials (∼4.8 mm). The efficient unimolecular photobleachable initiators show great potential in dental materials and 3D printings.

  1. A LED-based phosphorimeter for measurement of microcirculatory oxygen pressure.

    PubMed

    Guerci, Philippe; Ince, Yasin; Heeman, Paul; Faber, Dirk; Ergin, Bulent; Ince, Can

    2017-02-01

    Quantitative measurements of microcirculatory and tissue oxygenation are of prime importance in experimental research. The noninvasive phosphorescence quenching method has given further insight into the fundamental mechanisms of oxygen transport to healthy tissues and in models of disease. Phosphorimeters are devices dedicated to the study of phosphorescence quenching. The experimental applications of phosphorimeters range from measuring a specific oxygen partial pressure (Po 2 ) in cellular organelles such as mitochondria, finding values of Po 2 distributed over an organ or capillaries, to measuring microcirculatory Po 2 changes simultaneously in several organ systems. Most of the current phosphorimeters use flash lamps as a light excitation source. However, a major drawback of flash lamps is their inherent plasma glow that persists for tens of microseconds after the primary discharge. This complex distributed excitation pattern generated by the flash lamp can lead to inaccurate Po 2 readings unless a deconvolution analysis is performed. Using light-emitting diode (LED), a rectangular shaped light pulse can be generated that provides a more uniformly distributed excitation signal. This study presents the design and calibration process of an LED-based phosphorimeter (LED-P). The in vitro calibration of the LED-P using palladium(II)-meso-tetra(4-carboxyphenyl)-porphyrin (Pd-TCCP) as a phosphorescent dye is presented. The pH and temperature were altered to assess whether the decay times of the Pd-TCCP measured by the LED-P were significantly influenced. An in vivo validation experiment was undertaken to measure renal cortical Po 2 in a rat subjected to hypoxic ventilation conditions and ischemia/reperfusion. The benefits of using LEDs as a light excitation source are presented. Copyright © 2017 the American Physiological Society.

  2. The LED outdoor lighting revolution : Opportunities, threats and mitigation

    NASA Astrophysics Data System (ADS)

    Aube, Martin

    2017-01-01

    The presence of artificial light at night (ALAN) in environment is now known to have non negligible consequences on the night sky, the fauna, the flora and the human health. A real revolution is undergoing in the outdoor lighting industry threatens the night integrity. This revolution is driven by the advent of the cost-effective Light-Emitting Diode (LED) technology into the outdoor lighting industry. The LEDs provides many opportunities: they are long lasting, easily controlled, and generally allow a more efficient photometric design which, in term, may result in energy savings.After explaining the complex and non-linear behaviour of the propagation of the ALAN into the nocturnal environment, we will outline the potential impact of the ALAN on the human health and on the night sky, and we will introduce some dedicated indicators for its evaluation. We will focus on the role of the blue content of the ALAN in the evaluation of its impact. More specifically we will show how white LED technology, that often shows increased blue light content, compares to the traditional High Pressure Sodium technology. Finally, we will identify the possible mitigations to restrict the adverse impacts of the white LEDs in the urban and rural environment.

  3. The potential influence of LED lighting on mental illness.

    PubMed

    Bauer, Michael; Glenn, Tasha; Monteith, Scott; Gottlieb, John F; Ritter, Philipp S; Geddes, John; Whybrow, Peter C

    2018-02-01

    Two recent scientific breakthroughs may alter the treatment of mental illness, as discussed in this narrative review. The first was the invention of white light-emitting diodes (LEDs), which enabled an ongoing, rapid transition to energy-efficient LEDs for lighting, and the use of LEDs to backlight digital devices. The second was the discovery of melanopsin-expressing photosensitive retinal ganglion cells, which detect environmental irradiance and mediate non-image forming (NIF) functions including circadian entrainment, melatonin secretion, alertness, sleep regulation and the pupillary light reflex. These two breakthroughs are interrelated because unlike conventional lighting, white LEDs have a dominant spectral wavelength in the blue light range, near the peak sensitivity for the melanopsin system. Pertinent articles were identified. Blue light exposure may suppress melatonin, increase alertness, and interfere with sleep in young, healthy volunteers and in animals. Areas of concern in mental illness include the influence of blue light on sleep, other circadian-mediated symptoms, prescribed treatments that target the circadian system, measurement using digital apps and devices, and adolescent sensitivity to blue light. While knowledge in both fields is expanding rapidly, future developments must address the potential impact of blue light on NIF functions for healthy individuals and those with mental illness.

  4. Peer-Led Team Learning Helps Minority Students Succeed

    PubMed Central

    Snyder, Julia J.; Sloane, Jeremy D.; Dunk, Ryan D. P.; Wiles, Jason R.

    2016-01-01

    Active learning methods have been shown to be superior to traditional lecture in terms of student achievement, and our findings on the use of Peer-Led Team Learning (PLTL) concur. Students in our introductory biology course performed significantly better if they engaged in PLTL. There was also a drastic reduction in the failure rate for underrepresented minority (URM) students with PLTL, which further resulted in closing the achievement gap between URM and non-URM students. With such compelling findings, we strongly encourage the adoption of Peer-Led Team Learning in undergraduate Science, Technology, Engineering, and Mathematics (STEM) courses. PMID:26959826

  5. Peer-Led Team Learning Helps Minority Students Succeed.

    PubMed

    Snyder, Julia J; Sloane, Jeremy D; Dunk, Ryan D P; Wiles, Jason R

    2016-03-01

    Active learning methods have been shown to be superior to traditional lecture in terms of student achievement, and our findings on the use of Peer-Led Team Learning (PLTL) concur. Students in our introductory biology course performed significantly better if they engaged in PLTL. There was also a drastic reduction in the failure rate for underrepresented minority (URM) students with PLTL, which further resulted in closing the achievement gap between URM and non-URM students. With such compelling findings, we strongly encourage the adoption of Peer-Led Team Learning in undergraduate Science, Technology, Engineering, and Mathematics (STEM) courses.

  6. Semiconductor lasers vs LEDs in diagnostic and therapeutic medicine

    NASA Astrophysics Data System (ADS)

    Gryko, Lukasz; Zajac, Andrzej; Szymanska, Justyna; Blaszczak, Urszula; Palkowska, Anna; Kulesza, Ewa

    2016-12-01

    Semiconductor emitters are used in many areas of medicine, allowing for new methods of diagnosis, treatment and effective prevention of many diseases. The article presents selected areas of application of semiconductor sources in UVVIS- NIR range, where in recent years competition in semiconductor lasers and LEDs applications has been observed. Examples of applications of analyzed sources are indicated for LLLT, PDT and optical diagnostics using the procedure of color contrast. Selected results of LLLT research of the authors are presented that were obtained by means of the developed optoelectronic system for objectified irradiation and studies on the impact of low-energy laser and LED on lines of endothelial cells of umbilical vein. Usefulness of the spectrally tunable LED lighting system for diagnostic purposes is also demonstrated, also as an illuminator for surface applications - in procedure of variable color contrast of the illuminated object.

  7. Novel chip coating approaches to improve white LED technology

    NASA Astrophysics Data System (ADS)

    Hartmann, Paul; Schweighart, Marko; Sommer, Christian; Wenzl, Franz-P.; Zinterl, Ernst; Hoschopf, Hans; Pachler, Peter; Tasch, Stefan

    2008-02-01

    Key market requirements for white LEDs, especially in the general lighting and automotive headlamp segments call for improved concepts and performance of white LEDs based on phosphor conversion. Major challenges are small emission areas, highest possible intensities, long-term color stability, and spatial homogeneity of color coordinates. On the other hand, the increasingly high radiation power of the blue LEDs poses problems for all involved materials. Various thick film coating technologies are widely used for applying the color conversion layer to the semiconductor chip. We present novel concepts based on Silicate phosphors with high performance in terms of spatial homogeneity of the emission and variability of the color temperature. Numerical calculation of the optical properties with the help of state-of-the-art simulation tools was used as a basis for the practical optimization of the layer geometries.

  8. Nurse versus physician-led care for the management of asthma.

    PubMed

    Kuethe, Maarten C; Vaessen-Verberne, Anja A P H; Elbers, Roy G; Van Aalderen, Wim M C

    2013-02-28

    Asthma is the most common chronic disease in childhood and prevalence is also high in adulthood, thereby placing a considerable burden on healthcare resources. Therefore, effective asthma management is important to reduce morbidity and to optimise utilisation of healthcare facilities. To review the effectiveness of nurse-led asthma care provided by a specialised asthma nurse, a nurse practitioner, a physician assistant or an otherwise specifically trained nursing professional, working relatively independently from a physician, compared to traditional care provided by a physician. Our scope included all outpatient care for asthma, both in primary care and in hospital settings. We carried out a comprehensive search of databases including The Cochrane Library, MEDLINE and EMBASE to identify trials up to August 2012. Bibliographies of relevant papers were searched, and handsearching of relevant publications was undertaken to identify additional trials. Randomised controlled trials comparing nurse-led care versus physician-led care in asthma for the same aspect of asthma care. We used standard methodological procedures expected by The Cochrane Collaboration. Five studies on 588 adults and children were included concerning nurse-led care versus physician-led care. One study included 154 patients with uncontrolled asthma, while the other four studies including 434 patients with controlled or partly controlled asthma. The studies were of good methodological quality (although it is not possible to blind people giving or receiving the intervention to which group they are in). There was no statistically significant difference in the number of asthma exacerbations and asthma severity after treatment (duration of follow-up from six months to two years). Only one study had healthcare costs as an outcome parameter, no statistical differences were found. Although not a primary outcome, quality of life is a patient-important outcome and in the three trials on 380 subjects that

  9. Improved InGaN LED System Efficacy and Cost via Droop Reduction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wildeson, Isaac

    Efficiency droop is a non-thermal process intrinsic to indium gallium nitride light emitting diodes (LEDs) in which the external quantum efficiency (EQE) decreases with increasing drive current density. Mitigating droop would allow one to reduce the size of LEDs driven at a given current or to drive LEDs of given size at higher current while maintaining high efficiencies. In other words, droop mitigation can lead to significant gains in light output per dollar and/or light output per watt of input power. This project set an EQE improvement goal at high drive current density which was to be attained by improvingmore » the LED active region design and growth process following a droop mitigation strategy. The interactions between LED active region design parameters and efficiency droop were studied by modeling and experiments. The crystal defects that tend to form in more complex LED designs intended to mitigate droop were studied with advanced characterization methods that provided insight into the structural and electronic properties of the material. This insight was applied to improve the epitaxy process both in terms of active region design and optimization of growth parameters. The final project goals were achieved on schedule and an epitaxy process leading to LEDs with EQE exceeding the project target was demonstrated.« less

  10. Optical design of a LED searchlight system

    NASA Astrophysics Data System (ADS)

    Gong, Chen; Xu, Haiping; Liang, Jinhua; Liu, Yunfei; Yuan, Zengquan

    2018-01-01

    A 1200m visible searchlight system is designed based on photometry and application of geometric optics. To generate intensity distribution of this relatively powerful light beam we propose to use a high power LED and several refractive optical elements, which are composed of two plane-convex lenses and a conventional Fresnel lens. Two plane-convex lenses enable refraction of the side rays from the LED to the front direction which incident on the Fresnel lens. Fresnel lens, in its turn, concentrate the light flux and provide a nearly collimated beam to meet the requirement of forming a well-illuminated area across the road in the far field. Simulation data shows that this searchlight allow generating an appropriate illumination distribution for the long range requirements. A proof-of-concept prototype producing acceptable illuminance is developed.

  11. A new lifetime estimation model for a quicker LED reliability prediction

    NASA Astrophysics Data System (ADS)

    Hamon, B. H.; Mendizabal, L.; Feuillet, G.; Gasse, A.; Bataillou, B.

    2014-09-01

    LED reliability and lifetime prediction is a key point for Solid State Lighting adoption. For this purpose, one hundred and fifty LEDs have been aged for a reliability analysis. LEDs have been grouped following nine current-temperature stress conditions. Stress driving current was fixed between 350mA and 1A and ambient temperature between 85C and 120°C. Using integrating sphere and I(V) measurements, a cross study of the evolution of electrical and optical characteristics has been done. Results show two main failure mechanisms regarding lumen maintenance. The first one is the typically observed lumen depreciation and the second one is a much more quicker depreciation related to an increase of the leakage and non radiative currents. Models of the typical lumen depreciation and leakage resistance depreciation have been made using electrical and optical measurements during the aging tests. The combination of those models allows a new method toward a quicker LED lifetime prediction. These two models have been used for lifetime predictions for LEDs.

  12. A short-range optical wireless transmission method based on LED

    NASA Astrophysics Data System (ADS)

    Miao, Meiyuan; Chen, Ailin; Zhu, Mingxing; Li, Ping; Gao, Yingming; Zou, Nianyu

    2016-10-01

    As to electromagnetic wave interfere and only one to one transmission problem of Bluetooth, a short-range LED optical wireless transmission method is proposed to be complementary technology in this paper. Furthermore achieved image transmission through this method. The system makes C52 to be the mater controller, transmitter got data from terminals by USB and sends modulated signals with LED. Optical signal is detected by PD, through amplified, filtered with shaping wave from, and demodulated on receiver. Then send to terminals like PC and reverted back to original image. Analysis the performance from peak power and average power, power consumption of transmitter, relationship of bit error rate and modulation mode, and influence of ambient light, respectively. The results shows that image can be received accurately which uses this method. The most distant transmission distance can get to 1m with transmitter LED source of 1w, and the transfer rate is 14.4Kbit/s with OOK modulation mode on stabilization system, the ambient light effect little to LED transmission system in normal light environment. The method is a convenient to carry LED wireless short range transmission for mobile transmission equipment as a supplement of Bluetooth short-range transmission for its ISM band interfere, and the analysis method in this paper can be a reference for other similar systems. It also proves the system is feasibility for next study.

  13. LED-activated pheophorbide a in ovarian cancer cells: Cytotoxicity and apoptosis induction

    NASA Astrophysics Data System (ADS)

    Liu, L.; Xu, C. S.; Xia, X. S.; Leung, A. W. N.

    2011-02-01

    Pheophorbide a (Pa) from Chinese herbal medicine Scutellaria Barbata and Silkworm excreta has been proved to be potential photosensitizer. The present study investigated the cytotoxicity of ovarian cancer cells induced by LED-activated Pa using light microscopy with the SRB staining. We further investigated the apoptosis of the cells 6 h after LED-activated Pa using of the flow cytometer with PI staining and nuclear staining. The results showed that LED-activated Pa remarkably caused cell death of ovarian cancer cells. The condensation of chromatin, nuclear fragmentations, and 12.3% of cells containing subdiploid levels of DNA were found in the ovarian cancer cells after the treatment of LED-activated Pa. These data demonstrated that LED-activated Pa could cause significant cytotoxicity and apoptosis of ovarian cancer cells.

  14. Healthy marriage initiatives: on the need for empiricism in policy implementation.

    PubMed

    Johnson, Matthew D

    2012-01-01

    The association between marriage and well-being has led to policies that promote marital interventions and discourage divorce. These include federal initiatives specifically targeting poor couples and couples of color. While there are many prospective studies on marriage that have informed some couple interventions, the studies that are included in this literature sampled predominantly White and middle-class couples. By comparison, far less is known about the longitudinal predictors of relationship satisfaction and status for poor couples and couples of color. Therefore, it is unsurprising that preliminary data on applying current interventions to the couples targeted by these federal initiatives have been disappointing. In this article, I detail three concerns with these initiatives, propose a course of psychological research to address deficits in what is known about poor couples and couples of color, and make specific recommendations to enhance the effectiveness of these initiatives.

  15. Diversity initiatives in academic psychiatry: applying cultural competence.

    PubMed

    Lim, Russell F; Luo, John S; Suo, Shannon; Hales, Robert E

    2008-01-01

    This article describes the process of change in an academic department of psychiatry that has led to the development of a diversity initiative in teaching, research, recruitment, and services. The authors performed a literature review of diversity initiatives using PubMed. The authors then wrote a case study of the development of a diversity initiative at UC Davis. Some articles on diversity initiatives were found, but none that detailed the administrative process, funding, or sustainability of such initiatives. In 1999, the UC Davis Department of Psychiatry and Behavioral Sciences recognized the importance of issues of diversity and established the Diversity Advisory Committee, a group of department faculty and residents that explores and addresses the diversity needs of the department. In our observations, there are at least three requirements for a successful diversity initiative: a diverse patient population, a "critical mass" of interested faculty, and support of the administration. With these three factors in place, the Diversity Advisory Committee produced four Continuing Medical Education symposia focused on diversity topics, developed a 4-year cultural psychiatry curriculum and a 4-year religion and spirituality curriculum within the residency, and supported nine residents who received awards from the APA's Minority Fellowships in 8 years. Future plans include department-wide and medical school faculty-wide diversity training, educational research, and a postgraduate fellowship in cultural psychiatry. This article shows that a diversity initiative can be undertaken with interested minority and nonminority faculty, administrative support, and a diverse patient population. The authors hope this article will provide assistance to other academic departments in developing diversity initiatives.

  16. VLC-based indoor location awareness using LED light and image sensors

    NASA Astrophysics Data System (ADS)

    Lee, Seok-Ju; Yoo, Jong-Ho; Jung, Sung-Yoon

    2012-11-01

    Recently, indoor LED lighting can be considered for constructing green infra with energy saving and additionally providing LED-IT convergence services such as visible light communication (VLC) based location awareness and navigation services. For example, in case of large complex shopping mall, location awareness to navigate the destination is very important issue. However, the conventional navigation using GPS is not working indoors. Alternative location service based on WLAN has a problem that the position accuracy is low. For example, it is difficult to estimate the height exactly. If the position error of the height is greater than the height between floors, it may cause big problem. Therefore, conventional navigation is inappropriate for indoor navigation. Alternative possible solution for indoor navigation is VLC based location awareness scheme. Because indoor LED infra will be definitely equipped for providing lighting functionality, indoor LED lighting has a possibility to provide relatively high accuracy of position estimation combined with VLC technology. In this paper, we provide a new VLC based positioning system using visible LED lights and image sensors. Our system uses location of image sensor lens and location of reception plane. By using more than two image sensor, we can determine transmitter position less than 1m position error. Through simulation, we verify the validity of the proposed VLC based new positioning system using visible LED light and image sensors.

  17. Effects of near-infrared LED therapy on experimental tooth replantation in rats.

    PubMed

    Pigatto Mitihiro, Débora; de Paula Ramos, Solange; Corazza Montero, Janaína; Alves Campos, Aline; de Oliveira Toginho Filho, Dari; Dezan Garbelini, Cassia Cilene

    2017-02-01

    Dental avulsion damages periodontal tissues and may induce dentoalveolar ankylosis and root resorption after replantation. The aim of this work was to evaluate the effects of light-emitting diode (LED) therapy after tooth replantation. The upper right incisors of 36 male Wistar rats were extracted and replanted after 15 min. The control group (Co, n = 18) was submitted to replantation and the LED group (n = 18) was submitted to replantation and LED therapy (940 nm, 4 J cm -2 ) for three consecutive days (0, 24, and 48 h). Six animals from each group were euthanized at 7, 14, and 21 days for histological analysis. The upper left incisors were used as a negative control. Data were compared using the Fisher exact test, considering P < 0.05. After 7 days, the Co (73.3%) and LED (72.2%) groups presented areas of periodontal ligament necrosis. However, periodontal ligament necrosis was more frequent in the LED group at 14 (70%, P < 0.05) and 21 days (43.2%, P < 0.05) in relation to the Co group (33 and 21.6%). Inflammatory cell infiltration was more frequent in the Co group at 7 days (100%) than the LED group (24.4%, P < 0.05), but increased in the LED group after 21 days (83.3%, P < 0.05). Bone necrosis was more frequent in the LED group after 14 (79%, P < 0.05) and 21 days (60%, P < 0.005) than in the Co group (45% and 20%). Bone repair was evident in the Co group at 14 days. All of the replanted teeth had pulp necrosis. The results suggest that the application of LED therapy up to 48 h after tooth replantation may delay periodontal ligament repair. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  18. Floating aerial LED signage based on aerial imaging by retro-reflection (AIRR).

    PubMed

    Yamamoto, Hirotsugu; Tomiyama, Yuka; Suyama, Shiro

    2014-11-03

    We propose a floating aerial LED signage technique by utilizing retro-reflection. The proposed display is composed of LEDs, a half mirror, and retro-reflective sheeting. Directivity of the aerial image formation and size of the aerial image have been investigated. Furthermore, a floating aerial LED sign has been successfully formed in free space.

  19. Case file audit of Lidcombe program outcomes in a student-led stuttering clinic.

    PubMed

    McCulloch, Julia; Swift, Michelle C; Wagnitz, Bianca

    2017-04-01

    The current study aimed to benchmark clinical outcomes for preschool-aged clients (2;0-5;11 years old) that attended a student-led clinic and undertook the Lidcombe Program. A case file audit was undertaken for all preschool clients who attended the clinic between February 2008 and February 2013 and commenced the Lidcombe Program. Clients were grouped according to Stage 1 completion. A mixed ANOVA was used to test for differences between the groups in initial and final percentage syllables stuttered (%SS). Associations between case variable factors and treatment duration were investigated using Pearson correlations. Clients who completed Stage 1 had final %SS and severity rating (SR) scores comparable to the literature; however, the median Stage 1 duration was greater. Over half of the clients (57%) withdrew prior to completing Stage 1. These clients had a significantly higher %SS at final treatment session than their completing peers. Initial %SS and SR scores were the only case variables associated with treatment duration. Students can achieve the same short-term treatment outcomes for children who stutter using the Lidcombe Program as the current published literature; however, treatment duration is greater and may impact completion. Implications of this for clinical education are discussed.

  20. Longitudinal useful life analysis and replacement strategies for LED traffic indicators.

    DOT National Transportation Integrated Search

    2014-04-01

    The application of Light Emitting Diode (LED) lighting systems has experienced significant gro : wth in the transportation : sector over the past : ten : years. LED indication lifespans have significantly greater durations than previous technologies,...

  1. Longitudinal useful life analysis and replacement strategies for LED traffic indicators.

    DOT National Transportation Integrated Search

    2014-04-01

    The application of Light Emitting Diode (LED) lighting systems has experienced significant growth in : the transportation sector over the past 10 years. LED indication lifespans have significantly greater durations than : previous technologies, howev...

  2. Portrait of a Teacher-Led School

    ERIC Educational Resources Information Center

    Nazareno, Lori

    2013-01-01

    Imagine a school with no principal and with a leadership structure that holds teachers accountable for the learning of all students. About 50 such teacher-led schools currently operate across the United States, and this article tells the story of one of them. The Mathematics and Science Leadership Academy (MSLA) in Denver, Colorado, serves about…

  3. Polymer dispensing and embossing technology for the lens type LED packaging

    NASA Astrophysics Data System (ADS)

    Chien, Chien-Lin Chang; Huang, Yu-Che; Hu, Syue-Fong; Chang, Chung-Min; Yip, Ming-Chuen; Fang, Weileun

    2013-06-01

    This study presents a ring-type micro-structure design on the substrate and its corresponding micro fabrication processes for a lens-type light-emitting diode (LED) package. The dome-type or crater-type silicone lenses are achieved by a dispensing and embossing process rather than a molding process. Silicone with a high viscosity and thixotropy index is used as the encapsulant material. The ring-type micro structure is adopted to confine the dispensed silicone encapsulant so as to form the packaged lens. With the architecture and process described, this LED package technology herein has three merits: (1) the flexibility of lens-type LED package designs is enhanced; (2) a dome-type package design is used to enhance the intensity; (3) a crater-type package design is used to enhance the view angle. Measurement results show the ratio between the lens height and lens radius can vary from 0.4 to 1 by changing the volume of dispensed silicone. The view angles of dome-type and crater-type packages can reach 155° ± 5° and 175° ± 5°, respectively. As compared with the commercial plastic leaded chip carrier-type package, the luminous flux of a monochromatic blue light LED is improved by 15% by the dome-type package (improved by 7% by the crater-type package) and the luminous flux of a white light LED is improved by 25% by the dome-type package (improved by 13% by the crater-type package). The luminous flux of monochromatic blue light LED and white light LED are respectively improved by 8% and 12% by the dome-type package as compare with the crater-type package.

  4. LED traffic signal management system : final report.

    DOT National Transportation Integrated Search

    2016-06-01

    This research originated from the opportunity to develop a methodology to assess when LED (Light Emitting Diode) traffic signal modules begin to fail to meet the Institute of Transportation Engineers (ITE) performance specification for luminous inten...

  5. Testing a high-power LED based light source for hyperspectral imaging microscopy

    NASA Astrophysics Data System (ADS)

    Klomkaew, Phiwat; Mayes, Sam A.; Rich, Thomas C.; Leavesley, Silas J.

    2017-02-01

    Our lab has worked to develop high-speed hyperspectral imaging systems that scan the fluorescence excitation spectrum for biomedical imaging applications. Hyperspectral imaging can be used in remote sensing, medical imaging, reaction analysis, and other applications. Here, we describe the development of a hyperspectral imaging system that comprised an inverted Nikon Eclipse microscope, sCMOS camera, and a custom light source that utilized a series of high-power LEDs. LED selection was performed to achieve wavelengths of 350-590 nm. To reduce scattering, LEDs with low viewing angles were selected. LEDs were surface-mount soldered and powered by an RCD. We utilized 3D printed mounting brackets to assemble all circuit components. Spectraradiometric calibration was performed using a spectrometer (QE65000, Ocean Optics) and integrating sphere (FOIS-1, Ocean Optics). Optical output and LED driving current were measured over a range of illumination intensities. A normalization algorithm was used to calibrate and optimize the intensity of the light source. The highest illumination power was at 375 nm (3300 mW/cm2), while the lowest illumination power was at 515, 525, and 590 nm (5200 mW/cm2). Comparing the intensities supplied by each LED to the intensities measured at the microscope stage, we found there was a great loss in power output. Future work will focus on using two of the same LEDs to double the power and finding more LED and/or laser diodes and chips around the range. This custom hyperspectral imaging system could be used for the detection of cancer and the identification of biomolecules.

  6. EDITORIAL: Micro-pixellated LEDs for science and instrumentation

    NASA Astrophysics Data System (ADS)

    Dawson, Martin D.; Neil, Mark A. A.

    2008-05-01

    This Cluster Issue of Journal of Physics D: Applied Physics highlights micro-pixellated gallium nitride light-emitting diodes or `micro-LEDs', an emerging technology offering considerable attractions for a broad range of scientific and instrumentation applications. It showcases the results of a Research Councils UK (RCUK) Basic Technology Research programme (http://bt-onethousand.photonics.ac.uk), running from 2004-2008, which has drawn together a multi-disciplinary and multi-institutional research partnership to develop these devices and explore their potential. Images of LEDs Examples of GaN micro-pixel LEDs in operation. Images supplied courtesy of the Guest Editors. The partnership, of physicists, engineers and chemists drawn from the University of Strathclyde, Heriot-Watt University, the University of Sheffield and Imperial College London, has sought to move beyond the established mass-market uses of gallium nitride LEDs in illumination and lighting. Instead, it focuses on specialised solid-state micro-projection devices the size of a match-head, containing up to several thousand individually-addressable micro-pixel elements emitting light in the ultraviolet or visible regions of the spectrum. Such sources are pattern-programmable under computer control and can project into materials fixed or high-frame rate optical images or spatially-controllable patterns of nanosecond excitation pulses. These materials can be as diverse as biological cells and tissues, biopolymers, photoresists and organic semiconductors, leading to new developments in optical microscopy, bio-sensing and chemical sensing, mask-free lithography and direct writing, and organic electronics. Particular areas of interest are multi-modal microscopy, integrated forms of organic semiconductor lasers, lab-on-a-chip, GaN/Si optoelectronics and hybrid inorganic/organic semiconductor structures. This Cluster Issue contains four invited papers and ten contributed papers. The invited papers serve to set

  7. Peer-Led Guided in Calculus at University of South Florida

    ERIC Educational Resources Information Center

    Bénéteau, Catherine; Fox, Gordon; Xu, Xiaoying; Lewis, Jennifer E.; Ramachandran, Kandethody; Campbell, Scott; Holcomb, John

    2016-01-01

    This paper describes the development of a Peer-Led Guided Inquiry (PLGI) program for teaching calculus at the University of South Florida. This approach uses the POGIL (Process Oriented Guided Inquiry Learning) teaching strategy and the small group learning model PLTL (Peer-Led Team Learning). The developed materials used a learning cycle based on…

  8. Evaluation of OLED and edge-lit LED lighting panels

    NASA Astrophysics Data System (ADS)

    Mou, Xi; Narendran, Nadarajah; Zhu, Yiting; Freyssinier, Jean Paul

    2016-09-01

    Solid-state lighting (SSL) offers a new technology platform for lighting designers and end-users to illuminate spaces with low energy demand. Two types of SSL sources include organic light-emitting diodes (OLEDs) and light-emitting diodes (LEDs). OLED is an area light source, and its primary competing technology is the edge-lit LED panel. Generally, both of these technologies are considered similar in shape and appearance, but there is little understanding of how people perceive discomfort glare from large area light sources. The objective of this study was to evaluate discomfort glare for the two lighting technologies under similar operating conditions by gathering observers' reactions. The human factors study results showed no statistically significant difference in human response to discomfort glare between OLED and edge-lit LED panels when the two light sources produced the same lighting stimulus. This means both technologies appeared equally glary beyond a certain luminance.

  9. Silicate phosphors and white LED technology: improvements and opportunities

    NASA Astrophysics Data System (ADS)

    Sommer, Christian; Wenzl, Franz P.; Hartmann, Paul; Pachler, Peter; Schweighart, Marko; Leising, Guenther; Tasch, Stefan

    2007-09-01

    With the advent of a new generation of high brightness LEDs especially in the blue spectral range, white light technology based on phosphor conversion gains maturity for a successful penetration of, e.g., the general lighting market within the next years. Major challenges ahead are originating from the specific demands of the markets on small emission areas, highest possible intensities, long-term color stability, and spatial homogeneity of color coordinates. The LED industry more or less relies on the conversion phosphor classes of YAG, Sulfates, and Silicates, embedded in silicone matrices. A number of conformal coating technologies are in use. The optimization of the coating geometries with the help of software simulation offers a high potential for increased angular color homogeneity and high package densities, especially when secondary optics is in use. We report on recent progress in simulating parameters for improved white LEDs manufactured by coating technologies.

  10. LEDs as light source: examining quality of acquired images

    NASA Astrophysics Data System (ADS)

    Bachnak, Rafic; Funtanilla, Jeng; Hernandez, Jose

    2004-05-01

    Recent advances in technology have made light emitting diodes (LEDs) viable in a number of applications, including vehicle stoplights, traffic lights, machine-vision-inspection, illumination, and street signs. This paper presents the results of comparing images taken by a videoscope using two different light sources. One of the sources is the internal metal halide lamp and the other is a LED placed at the tip of the insertion tube. Images acquired using these two light sources were quantitatively compared using their histogram, intensity profile along a line segment, and edge detection. Also, images were qualitatively compared using image registration and transformation. The gray-level histogram, edge detection, image profile and image registration do not offer conclusive results. The LED light source, however, produces good images for visual inspection by an operator. The paper will present the results and discuss the usefulness and shortcomings of various comparison methods.

  11. Controllable light beam shaper in LED lamp

    NASA Astrophysics Data System (ADS)

    Nessemon, K. D.; Popov, I. V.; Belyaev, V. V.; Belyaev, A. A.; Velichko, V. K.

    2018-03-01

    A design of an LED lamp with controllable shape and intensity of the light beam formed is described. The effect is achieved by dividing the light irradiating area for four section and their special fixation and fastening.

  12. Local initiatives to access emergency obstetric and neonatal care in Burkina Faso.

    PubMed

    Yaméogo, Wambi M E; Ouédraogo, Talatou M; Kouanda, Seni

    2016-11-01

    To describe the various local initiatives to access emergency obstetric and neonatal care in Burkina Faso. An existing framework was used to review the three processes for local initiatives: emergence, formulation, and implementation. Multiple case studies were conducted, followed by literature review and semi-structured interviews with key informants. Sixteen districts had implemented local initiatives, including cost sharing, free care for women and children, and free care for delivery and cesareans. Most districts (n=10) had implemented the cost-sharing intervention. These initiatives were initiated by local actors as well as nongovernmental organizations. The profile of those involved led to different ways of handling the emergence and formulation processes. At implementation, these initiatives faced many issues including late payment of contributions, low involvement of local governments, and equity in participation. There are some issues in the implementation and sustainability of the local initiatives. Although many initiatives exist, these are unable to fully address the financial barriers to care. However, these initiatives highlight context-based financial barriers that must be taken into account to accelerate universal access to health care. Copyright © 2016 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.

  13. Child-Led Enquiry in Primary Science

    ERIC Educational Resources Information Center

    Dunlop, Lynda; Compton, Kirsty; Clarke, Linda; McKelvey-Martin, Valerie

    2015-01-01

    This research describes and evaluates the application of a child-led approach to scientific enquiry (the Community of Scientific Enquiry, CoSE) to children aged 8-11 (Key Stage 2) in Northern Ireland. Primary teachers were introduced to CoSE at a workshop and asked to evaluate its implementation with their class. Results from children (n = 364)…

  14. Student-Led Conferences: Students Taking Responsibility

    ERIC Educational Resources Information Center

    Nauss, Sherri A.

    2010-01-01

    One of the many challenges that face middle grade students, parents, and teachers is the student's lack of ownership of their academic achievements. Student-led conferences are a unique way to engage the student and the parent in the academic progress. Parents and teachers discuss the student's attitude toward the work, the student's work ethic in…

  15. Faculty-led Teams: Key Success Factors.

    ERIC Educational Resources Information Center

    Dance-Bennink, Terry; Kincaid, Kate; Groombridge, Tracy

    Sir Sandford Fleming College in Ontario, Canada is in the process of transforming itself from a teaching-based college to a student-centered organization. Faculty-led teams are a critical element in this transformation. With active support from its faculty union, Fleming has reduced its administrative ranks by one-third and created a host of teams…

  16. Electroluminescence properties of LEDs based on electron-irradiated p-Si

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sobolev, N. A., E-mail: nick@sobolev.ioffe.rssi.ru; Shtel’makh, K. F.; Kalyadin, A. E.

    2016-02-15

    The electroluminescence (EL) in n{sup +}–p–p{sup +} light-emitting-diode (LED) structures based on Si irradiated with electrons and annealed at high temperature is studied. The LEDs are fabricated by the chemical- vapor deposition of polycrystalline silicon layers doped with high concentrations of boron and phosphorus. Transformation of the EL spectra with current in the LEDs is well described by six Gaussian curves. The peak positions of these curves are current-independent and equal to 1233, 1308, 1363, 1425, 1479, and 1520 nm. The dependences of the integrated EL intensity and of the full-width at half-maximum (FWHM) of the lines on current aremore » examined.« less

  17. Permanent transparent color-warming glazes for dimmable and non-dimmable LED bulbs

    NASA Astrophysics Data System (ADS)

    Spanard, Jan-Marie A.

    2014-02-01

    Illuminant metameric failure is frequently experienced when viewing material samples under LED generated light vs. traditional incandescent light. LED light temperatures can be improved with phosphor coatings, but long-wave red light is still generally absent in LED "warm-white" light, resulting in metameric failure of orange-to-red objects. Drawing on techniques developed for the architectural restoration of stained glass, we find that transparent, heat-resistant, permanent, pigmented coatings can be applied to any glass, aluminum or plastic surface of an LED bulb, including the phosphor plate, dome or envelope, to produce warmer visible light than in current warm-light LED bulbs. These glazes can be applied in combination with existing technologies to better tune the LED emitted light or they may be used alone. These pigmented coatings include, but are not limited to, those made by suspending inorganic materials in potassium silicates or durable transparent pigmented resins. The pigmented resin glazes may be produced in either a clear gloss vehicle or an iridescent, light diffusing transparent base. Further, a graduated density of the tinted glazes on dimmable bulbs allow the light to change color as wattage is diminished. The glazes may be applied in the manufacturing of the bulb or marketed to current bulb owners as an after-market product to better tune the thousands of LED light bulbs currently in use.

  18. Novel wafer stepper with violet LED light source

    NASA Astrophysics Data System (ADS)

    Ting, Yung-Chiang; Shy, Shyi-Long

    2014-03-01

    Novel wafer stepper by using contact or proximity printing will be developed, using violet LED light source to replace Hg Arc. lamp or laser. Mirror, filter and condenser lens for Hg Arc. Lamp or laser and reduction lens for projection printing can be discarded. Reliability and manufacturing cost of wafer stepper can be improved. Exposure result by using IP3600 resist and wafer stepper with violet LED light source (wave-length 360nm to 410 nm) will be obtained. This novel wafer stepper can be used for 3DIC, MEMS and bio-chip lithography application by using thin and thick resist with sub-micron to 100 micron thickness.

  19. Produsage in a/synchronous learner-led e-learning

    NASA Astrophysics Data System (ADS)

    Kazmer, Michelle M.

    2011-04-01

    Creating a successful produsage environment for a required course taught via e-learning requires analyzing various factors: the learning context, learner-led education in required classes, the structure of the class, and reflections and evaluations of each semester's iteration of the course. Taking a produsage perspective, this paper analyzes the long-term development of a required graduate-level course in information organization. The course is examined closely to show how its materials, assignments, technology, instruction, and culture contribute to a learner-led produsage environment and lasting knowledge creation. The analysis leads to implications for course design and working with learners to create knowledge that may be applied in multiple settings.

  20. LED and Semiconductor Photo-effects on Living Things

    NASA Astrophysics Data System (ADS)

    Fujiyasu, Hiroshi; Ishigaki, Takemitsu; Fujiyasu, Kentarou; Ujihara, Shirou; Watanabe, Naoharu; Sunayama, Shunji; Ikoma, Shuuji

    We have studied LED irradiation effects on plants and animals in the visible to UV region of light from GaN LEDs. The results are as follows. Blue light considers to be effective for pearl cultivation or for attraction of small fishes living in near the surface of sea such as Pompano or Sardine, white light radiation is effective for cultivation of botanical plankton for shells. Other experiments of UV light irradiation attracting effect on baby sea turtle and the germination UV effect of mushroom, green light weight enhance effect on baby pigs, light vernalization effect of vegitable and Ge far infrared therapic effect on human body are also given.

  1. Accelerated optical polymer aging studies for LED luminaire applications

    NASA Astrophysics Data System (ADS)

    Estupiñán, Edgar; Wendling, Peter; Kostrun, Marijan; Garner, Richard

    2013-09-01

    There is a need in the lighting industry to design and implement accelerated aging methods that accurately simulate the aging process of LED luminaire components. In response to this need, we have built a flexible and reliable system to study the aging characteristics of optical polymer materials, and we have employed it to study a commercially available LED luminaire diffuser made of PMMA. The experimental system consists of a "Blue LED Emitter" and a working surface. Both the temperatures of the samples and the optical powers of the LEDs are appropriately characterized in the system. Several accelerated aging experiments are carried out at different temperatures and optical powers over a 90 hour period and the measured transmission values are used as inputs to a degradation model derived using plausibility arguments. This model seems capable of predicting the behavior of the material as a function of time, temperature and optical power. The model satisfactorily predicts the measured transmission values of diffusers aged in luminaires at two different times and thus can be used to make application recommendations for this material. Specifically, at 35000 hours (the manufacturer's stated life of the luminaire) and at the typical operational temperature of the diffuser, the model predicts a transmission loss of only a few percent over the original transmission of the material at 450 nm, which renders this material suitable for this application.

  2. Study of LED layout in indoor visible light communication and performance analysis

    NASA Astrophysics Data System (ADS)

    Wang, Jiaan; Che, Ying; Wang, Xinlan; Guo, Linyang; Li, Jing

    2017-10-01

    Light emitting diodes(LED) could provide both illumination and data communication in indoor visible light communication(VLC) that owns the modulation bandwith from several from several MHz to seneral hundreds of MHz. The layout of LED plays an important role in maintaining a steady optical power distribution over the receiving plane. The existing rectangular LED layout does not provide a full coverage on the receiving plane leaving receiving optical power outage area, which in turn affects the best performance of the VLC system. This paper design a circular layout scheme of LED in 5mX5mX3m room based on the criterion of the illumination minimum mean square deviation. The influence of the distribution of the intensity of illumination with the radius of 1m and 1.5m,for including the wall reflection and not including the wall reflection, and make a comparison with rectangular LED layout of illumination distribution, when the number of LEDs with rectangular layout as same as circular layout. Including the number of LEDs are 4 and 16.For a specific simulation parameters as following:height of receiving plane is 0.85m,a single LEDs is composed of 60X60 LED chips, the parameters of a single chip is that transmitting power is 20mW,center luminous intensity is 0.73cd.semiangle at half power is 70deg.The parameters of concentrator is that photodiode area is 1cm2,photodiode responsivity is 0.4,field of view at the receiver is 85deg.Other parameters are that reflective index of concentrator is 1.5,reflectivity of wall is 0.8.Circular layout and rectangular layout are analyzed through simulation of the received optical power distribution, signal noise ratio distribution in non line of sight(including the wall reflection) and line of sight(not including the wall reflection),when the number of the LED is different. It is clear from the results that the received optical power distribution of non line of sight is better than line of sight, when the number of the LED are same, but

  3. GaN-based micro-LED arrays on flexible substrates for optical cochlear implants

    NASA Astrophysics Data System (ADS)

    Goßler, Christian; Bierbrauer, Colin; Moser, Rüdiger; Kunzer, Michael; Holc, Katarzyna; Pletschen, Wilfried; Köhler, Klaus; Wagner, Joachim; Schwaerzle, Michael; Ruther, Patrick; Paul, Oliver; Neef, Jakob; Keppeler, Daniel; Hoch, Gerhard; Moser, Tobias; Schwarz, Ulrich T.

    2014-05-01

    Currently available cochlear implants are based on electrical stimulation of the spiral ganglion neurons. Optical stimulation with arrays of micro-sized light-emitting diodes (µLEDs) promises to increase the number of distinguishable frequencies. Here, the development of a flexible GaN-based micro-LED array as an optical cochlear implant is reported for application in a mouse model. The fabrication of 15 µm thin and highly flexible devices is enabled by a laser-based layer transfer process of the GaN-LEDs from sapphire to a polyimide-on-silicon carrier wafer. The fabricated 50 × 50 µm2 LEDs are contacted via conducting paths on both p- and n-sides of the LEDs. Up to three separate channels could be addressed. The probes, composed of a linear array of the said µLEDs bonded to the flexible polyimide substrate, are peeled off the carrier wafer and attached to flexible printed circuit boards. Probes with four µLEDs and a width of 230 µm are successfully implanted in the mouse cochlea both in vitro and in vivo. The LEDs emit 60 µW at 1 mA after peel-off, corresponding to a radiant emittance of 6 mW mm-2.

  4. Precise Temperature Mapping of GaN-Based LEDs by Quantitative Infrared Micro-Thermography

    PubMed Central

    Chang, Ki Soo; Yang, Sun Choel; Kim, Jae-Young; Kook, Myung Ho; Ryu, Seon Young; Choi, Hae Young; Kim, Geon Hee

    2012-01-01

    A method of measuring the precise temperature distribution of GaN-based light-emitting diodes (LEDs) by quantitative infrared micro-thermography is reported. To reduce the calibration error, the same measuring conditions were used for both calibration and thermal imaging; calibration was conducted on a highly emissive black-painted area on a dummy sapphire wafer loaded near the LED wafer on a thermoelectric cooler mount. We used infrared thermal radiation images of the black-painted area on the dummy wafer and an unbiased LED wafer at two different temperatures to determine the factors that degrade the accuracy of temperature measurement, i.e., the non-uniform response of the instrument, superimposed offset radiation, reflected radiation, and emissivity map of the LED surface. By correcting these factors from the measured infrared thermal radiation images of biased LEDs, we determined a precise absolute temperature image. Consequently, we could observe from where the local self-heat emerges and how it distributes on the emitting area of the LEDs. The experimental results demonstrated that highly localized self-heating and a remarkable temperature gradient, which are detrimental to LED performance and reliability, arise near the p-contact edge of the LED surface at high injection levels owing to the current crowding effect. PMID:22666050

  5. Stem cells in prostate cancer initiation and progression

    PubMed Central

    Lawson, Devon A.; Witte, Owen N.

    2007-01-01

    Peter Nowell and David Hungerford’s discovery of the Philadelphia chromosome facilitated many critical studies that have led to a paradigm shift in our understanding of cancer as a disease of stem cells. This Review focuses on the application of these concepts to investigation of the role of stem cells in prostate cancer initiation and progression. Major strides in the development of in vitro and in vivo assays have enabled identification and characterization of prostate stem cells as well as functional evaluation of the tumorigenic effects of prostate cancer–related genetic alterations. PMID:17671638

  6. Process and Outcomes From a Youth-Led Campaign to Address Healthy Eating in an Urban High School.

    PubMed

    Frerichs, Leah; Sjolie, Sarah; Curtis, Matthew; Peterson, Melissa; Huang, Terry T-K

    2015-12-01

    This article describes a pilot youth advocacy initiative for obesity prevention informed by social cognitive theory, social network theory, and theories of community mobilization. With assistance from school and health leaders, adolescent-aged youth led a cafeteria food labeling and social marketing campaign. We implemented an anonymous survey 2 weeks prior to and again at the conclusion of the campaign, and used cafeteria records to track servings of fruits and vegetables. The campaign resulted in a significant increase in youths' confidence to identify healthy foods (OR 1.97, 95 % CI 1.01, 3.84, p = .048), and a significant increase in per person per day servings of fruits (0.02, p = .03) and vegetables (0.01, p = .02). The results of our pilot were promising, and the integration of concepts from multiple theories benefited the implementation process. Obesity prevention initiatives should include strategies that encourage youth to create health promotion community networks and lead changes to their social and physical environments.

  7. Novel Coatings for Enhancement of Light-Emitting Diodes (LEDs)

    DTIC Science & Technology

    2006-10-28

    quantum efficiency of LEDs. SAIC’s strength is this area is a proprietary nonimaging optics code. In consultation with Lumileds, SAIC developed designs for...five different optical ele- ments that collect and project light from a LED. The simulations showed that the designs achieve a significant improvement... optical microscope at 100x power the coating is not visible. Fire sample 6DecO4P1 in tube furnace As a first test, sample 6Dec04P1 was progressively

  8. High power LED standard light sources for photometric applications

    NASA Astrophysics Data System (ADS)

    Ivashin, Evgeniy; Ogarev, Sergey; Khlevnoy, Boris; Shirokov, Stanislav; Dobroserdov, Dmitry; Sapritsky, Victor

    2018-02-01

    High power LED light sources have been developed as possible new VNIIOFI standard sources for luminous intensity, luminous flux and colour measurements. Stability, repeatability and spatial uniformity of the sources were investigated and demonstrated high accuracy and homogeneity. The paper describes different tests on one of the manufactured sources. In the future, these LED light sources are planned to be used as standard luminous flux sources to transfer the units of luminous intensity and luminous flux from gonio-spectrometer to sphere-spectrometer.

  9. Biological Research in Canisters (BRIC) - Light Emitting Diode (LED)

    NASA Technical Reports Server (NTRS)

    Levine, Howard G.; Caron, Allison

    2016-01-01

    The Biological Research in Canisters - LED (BRIC-LED) is a biological research system that is being designed to complement the capabilities of the existing BRIC-Petri Dish Fixation Unit (PDFU) for the Space Life and Physical Sciences (SLPS) Program. A diverse range of organisms can be supported, including plant seedlings, callus cultures, Caenorhabditis elegans, microbes, and others. In the event of a launch scrub, the entire assembly can be replaced with an identical back-up unit containing freshly loaded specimens.

  10. A comparative study of fluorescent and LED lighting in industrial facilities

    NASA Astrophysics Data System (ADS)

    Perdahci PhD, C.; Akin BSc, H. C.; Cekic Msc, O.

    2018-05-01

    Industrial facilities have always been in search for reducing outgoings and minimizing energy consumption. Rapid developments in lighting technology require more energy efficient solutions not only for industries but also for many sectors and for households. Addition of solid-state technology has brought LED lamps into play and with LED lamp usage, efficacy level has reached its current values. Lighting systems which uses fluorescent and LED lamps have become the prior choice for many industrial facilities. This paper presents a comparative study about fluorescent and LED based indoor lighting systems for a warehouse building in an industrial facility in terms of lighting distribution values, colour rendering, power consumption, energy efficiency and visual comfort. Both scenarios have been modelled and simulated by using Relux and photometric data for the luminaires have been gathered by conducting tests and measurements in an accredited laboratory.

  11. Digital LED Pixels: Instructions for use and a characterization of their properties.

    PubMed

    Jones, Pete R; Garcia, Sara E; Nardini, Marko

    2016-12-01

    This article details how to control light emitting diodes (LEDs) using an ordinary desktop computer. By combining digitally addressable LEDs with an off-the-shelf microcontroller (Arduino), multiple LEDs can be controlled independently and with a high degree of temporal, chromatic, and luminance precision. The proposed solution is safe (can be powered by a 5-V battery), tested (has been used in published research), inexpensive (∼ $60 + $2 per LED), highly interoperable (can be controlled by any type of computer/operating system via a USB or Bluetooth connection), requires no prior knowledge of electrical engineering (components simply require plugging together), and uses widely available components for which established help forums already exist. Matlab code is provided, including a 'minimal working example' of use suitable for use by beginners. Properties of the recommended LEDs are also characterized, including their response time, luminance profile, and color gamut. Based on these, it is shown that the LEDs are highly stable in terms of both luminance and chromaticity, and do not suffer from issues of warm-up, chromatic shift, and slow response times associated with traditional CRT and LCD monitor technology.

  12. LED traffic signal management system : tech summary.

    DOT National Transportation Integrated Search

    2016-06-01

    The light source of a signal module is comprised of an array of multiple individual light emitting diodes (LEDs). : Fading of the array over its operational life is a serious concern of traffic engineers throughout the nation. The : Institute of Tran...

  13. Design of a detection system of highlight LED arrays' effect on the human organization

    NASA Astrophysics Data System (ADS)

    Chen, Shuwang; Shi, Guiju; Xue, Tongze; Liu, Yanming

    2009-05-01

    LED (Light Emitting Diode) has many advantages in the intensity, wavelength, practicality and price, so it is feasible to apply in biomedicine engineering. A system for the research on the effect of highlight LED arrays to human organization is designed. The temperature of skin surface can rise if skin and organization are in irradiation by highlight LED arrays. The metabolism and blood circulation of corresponding position will be quicker than those not in the shine, so the surface temperature will vary in different position of skin. The structure of LED source arrays system is presented and a measure system for studying LED's influence on human organization is designed. The temperature values of shining point are detected by infrared temperature detector. Temperature change is different according to LED parameters, such as the number, irradiation time and luminous intensity of LED. Experimental device is designed as an LED arrays pen. The LED arrays device is used to shine the points of human body, then it may effect on personal organization as well as the acupuncture. The system is applied in curing a certain skin disease, such as age pigment, skin cancer and fleck.

  14. Improved breakdown characteristics of monolithically integrated III-nitride HEMT-LED devices using carbon doping

    NASA Astrophysics Data System (ADS)

    Liu, Chao; Liu, Zhaojun; Huang, Tongde; Ma, Jun; May Lau, Kei

    2015-03-01

    We report selective growth of AlGaN/GaN high electron mobility transistors (HEMTs) on InGaN/GaN light emitting diodes (LEDs) for monolithic integration of III-nitride HEMT and LED devices (HEMT-LED). To improve the breakdown characteristics of the integrated HEMT-LED devices, carbon doping was introduced in the HEMT buffer by controlling the growth pressure and V/III ratio. The breakdown voltage of the fabricated HEMTs grown on LEDs was enhanced, without degradation of the HEMT DC performance. The improved breakdown characteristics can be attributed to better isolation of the HEMT from the underlying conductive p-GaN layer of the LED structure.

  15. Significant performance enhancement of InGaN/GaN nanorod LEDs with multi-layer graphene transparent electrodes by alumina surface passivation

    NASA Astrophysics Data System (ADS)

    Latzel, M.; Büttner, P.; Sarau, G.; Höflich, K.; Heilmann, M.; Chen, W.; Wen, X.; Conibeer, G.; Christiansen, S. H.

    2017-02-01

    Nanotextured surfaces provide an ideal platform for efficiently capturing and emitting light. However, the increased surface area in combination with surface defects induced by nanostructuring e.g. using reactive ion etching (RIE) negatively affects the device’s active region and, thus, drastically decreases device performance. In this work, the influence of structural defects and surface states on the optical and electrical performance of InGaN/GaN nanorod (NR) light emitting diodes (LEDs) fabricated by top-down RIE of c-plane GaN with InGaN quantum wells was investigated. After proper surface treatment a significantly improved device performance could be shown. Therefore, wet chemical removal of damaged material in KOH solution followed by atomic layer deposition of only 10 {nm} alumina as wide bandgap oxide for passivation were successfully applied. Raman spectroscopy revealed that the initially compressively strained InGaN/GaN LED layer stack turned into a virtually completely relaxed GaN and partially relaxed InGaN combination after RIE etching of NRs. Time-correlated single photon counting provides evidence that both treatments—chemical etching and alumina deposition—reduce the number of pathways for non-radiative recombination. Steady-state photoluminescence revealed that the luminescent performance of the NR LEDs is increased by about 50% after KOH and 80% after additional alumina passivation. Finally, complete NR LED devices with a suspended graphene contact were fabricated, for which the effectiveness of the alumina passivation was successfully demonstrated by electroluminescence measurements.

  16. Significant performance enhancement of InGaN/GaN nanorod LEDs with multi-layer graphene transparent electrodes by alumina surface passivation.

    PubMed

    Latzel, M; Büttner, P; Sarau, G; Höflich, K; Heilmann, M; Chen, W; Wen, X; Conibeer, G; Christiansen, S H

    2017-02-03

    Nanotextured surfaces provide an ideal platform for efficiently capturing and emitting light. However, the increased surface area in combination with surface defects induced by nanostructuring e.g. using reactive ion etching (RIE) negatively affects the device's active region and, thus, drastically decreases device performance. In this work, the influence of structural defects and surface states on the optical and electrical performance of InGaN/GaN nanorod (NR) light emitting diodes (LEDs) fabricated by top-down RIE of c-plane GaN with InGaN quantum wells was investigated. After proper surface treatment a significantly improved device performance could be shown. Therefore, wet chemical removal of damaged material in KOH solution followed by atomic layer deposition of only 10 [Formula: see text] alumina as wide bandgap oxide for passivation were successfully applied. Raman spectroscopy revealed that the initially compressively strained InGaN/GaN LED layer stack turned into a virtually completely relaxed GaN and partially relaxed InGaN combination after RIE etching of NRs. Time-correlated single photon counting provides evidence that both treatments-chemical etching and alumina deposition-reduce the number of pathways for non-radiative recombination. Steady-state photoluminescence revealed that the luminescent performance of the NR LEDs is increased by about 50% after KOH and 80% after additional alumina passivation. Finally, complete NR LED devices with a suspended graphene contact were fabricated, for which the effectiveness of the alumina passivation was successfully demonstrated by electroluminescence measurements.

  17. LED phototherapy on midpalatal suture after rapid maxilla expansion: a Raman spectroscopic study

    NASA Astrophysics Data System (ADS)

    Rosa, Cristiane B.; Habib, Fernando Antonio L.; de Araújo, Telma M.; dos Santos, Jean N.; Cangussu, Maria Cristina T.; Barbosa, Artur Felipe S.; de Castro, Isabele Cardoso V.; Soares, Luiz Guilherme P.; Pinheiro, Antonio L. B.

    2015-03-01

    A quick bone formation after maxillary expansion would reduce treatment timeand the biomodulating effects of LED light could contribute for it. The aim of this study was to analyze the effect of LED phototherapy on the acceleration of bone formation at the midpalatal suture after maxilla expansion. Thirty rats divided into 6 groups were used on the study at 2 time points - 7 days: Control; Expansion; and Expansion + LED; and 14 days: Expansion; Expansion + LED in the first week; Expansion and LED in the first and second weeks. LED irradiation occurred at every 48 h during 2 weeks. Expansion was accomplished using a spatula and maintained with a triple helicoid of 0.020" stainless steel orthodontic wire. A LED light (λ850 ± 10nm, 150mW ± 10mW, spot of 0.5cm2, t=120 sec, SAEF of 18J/cm2) was applied in one point in the midpalatal suture immediately behind the upper incisors. Near infrared Raman spectroscopic analysis of the suture region was carried and data submitted to statistical analyzes (p≤0.05). Raman spectrum analysis demonstrated that irradiation increased hydroxyapatite in the midpalatal suture after expansion. The results of this indicate that LED irradiation; have a positive biomodulation contributing to the acceleration of bone formation in the midpalatal suture after expansion procedure.

  18. Enhancement of astaxanthin production using Haematococcus pluvialis with novel LED wavelength shift strategy.

    PubMed

    Xi, Tianqi; Kim, Dae Geun; Roh, Seong Woon; Choi, Jong-Soon; Choi, Yoon-E

    2016-07-01

    Haematococcus pluvialis is a green microalga of particular interest, since it is considered the best potential natural source of astaxanthin, which is widely used as an additive for natural pigmentation. In addition, astaxanthin has recently garnered commercial interest as a nutraceutical, cosmetic, and pharmaceutical. However, producing astaxanthin from H. pluvialis necessitates separation with distinctive culture conditions, dividing between the microalgae growth and the astaxanthin production stages. Light-emitting diodes (LEDs) have emerged as a replacement for traditional light sources, and LED applications are now rapidly expanding to multiple areas in fields such as biotechnology. However, further detail application into microalgae biotechnology remains limited. In this study, we have attempted to establish new protocols based on the specific wavelength of LEDs for the cultivation and production of astaxanthin using H. pluvialis. Specifically, we applied red LEDs for microalgae cell growth and then switched to blue LEDs to induce astaxanthin biosynthesis. The result showed that astaxanthin productions based on a wavelength shift from red to blue were significantly increased, compared to those with continuous illumination using red LEDs. Furthermore, additional increase of astaxanthin production was achieved with simultaneous application of exogenous carbon with blue LED illumination. Our approach based on the proper manipulation of LED wavelengths upon H. pluvialis cell stages will enable the improvement of biomass and enhance astaxanthin production using H. pluvialis.

  19. LED firm rejects Nobel laureate's olive branch

    NASA Astrophysics Data System (ADS)

    Banks, Michael

    2014-12-01

    Nobel laureate Shuji Nakamura says that he is not going to try and improve relations with his former employer, which he sued in 2001 over his development of the blue light-emitting diode (LED), after receiving a snub from them last month.

  20. Accurate chromatic control and color rendering optimization in LED lighting systems using junction temperature feedback

    NASA Astrophysics Data System (ADS)

    Sisto, Marco Michele; Gauvin, Jonny

    2014-09-01

    Accurate color control of LED lighting systems is a challenging task: noticeable chromaticity shifts are commonly observed in mixed-color and phosphor converted LEDs due to intensity dimming. Furthermore, the emitted color varies with the LED temperature. We present a novel color control method for tri-chromatic and tetra-chromatic LEDs, which enable to set and maintain the LED emission at a target color, or combination of correlated color temperature (CCT) and intensity. The LED color point is maintained over variations in the LED junctions' temperatures and intensity dimming levels. The method does not require color feedback sensors, so to minimize system complexity and cost, but relies on estimation of the LED junctions' temperatures from the junction voltages. If operated with tetra-chromatic LEDs, the method allows meeting an additional optimization criterion: for example, the maximization of a color rendering metric like the Color Rendering Index (CRI) or the Color Quality Scale (CQS), thus providing a high quality and clarity of colors on the surface illuminated by the LED. We demonstrate the control of a RGBW LED at target D65 white point with CIELAB color difference metric triangle;a,bE < 1 for simultaneous variations of flux from approximately 30 lm to 100 lm and LED heat sink temperature from 25°C to 58°C. In the same conditions, we demonstrate a CCT error <1%. Furthermore, the method allows varying the LED CCT from 5500K to 8000K while maintaining luminance within 1% of target. Further work is ongoing to evaluate the stability of the method over LED aging.

  1. Physical Limitations of Phosphor layer thickness and concentration for White LEDs.

    PubMed

    Tan, Cher Ming; Singh, Preetpal; Zhao, Wenyu; Kuo, Hao-Chung

    2018-02-05

    Increasing phosphor layer thickness and concentration can enhance the lumen flux of white LED (W-LED). In this work, we found that increasing the phosphor layer thickness and concentration can increase its temperature, and there is also a maximum thickness and concentration beyond which their increase will not lead to lumen increase, but only temperature increase. Higher thickness and higher concentration also results in warm light instead of White light. The maximum thickness and concentration are found to be limited by the scattering of light rays with higher % decrease of blue light rays than the yellow light rays. The results obtained in this work can also be used to compute the temperature and thermo-mechanical stress distribution of an encapsulated LED, demonstrating its usefulness to the design of encapsulated LED packages. Simulation software like ANSYS and TracePro are used extensively to verify the root cause mechanisms.

  2. Satellite Calibration With LED Detectors at Mud Lake

    NASA Technical Reports Server (NTRS)

    Hiller, Jonathan D.

    2005-01-01

    Earth-monitoring instruments in orbit must be routinely calibrated in order to accurately analyze the data obtained. By comparing radiometric measurements taken on the ground in conjunction with a satellite overpass, calibration curves are derived for an orbiting instrument. A permanent, automated facility is planned for Mud Lake, Nevada (a large, homogeneous, dry lakebed) for this purpose. Because some orbiting instruments have low resolution (250 meters per pixel), inexpensive radiometers using LEDs as sensors are being developed to array widely over the lakebed. LEDs are ideal because they are inexpensive, reliable, and sense over a narrow bandwidth. By obtaining and averaging widespread data, errors are reduced and long-term surface changes can be more accurately observed.

  3. Biologically inspired LED lens from cuticular nanostructures of firefly lantern

    PubMed Central

    Kim, Jae-Jun; Lee, Youngseop; Kim, Ha Gon; Choi, Ki-Ju; Kweon, Hee-Seok; Park, Seongchong; Jeong, Ki-Hun

    2012-01-01

    Cuticular nanostructures found in insects effectively manage light for light polarization, structural color, or optical index matching within an ultrathin natural scale. These nanostructures are mainly dedicated to manage incoming light and recently inspired many imaging and display applications. A bioluminescent organ, such as a firefly lantern, helps to out-couple light from the body in a highly efficient fashion for delivering strong optical signals in sexual communication. However, the cuticular nanostructures, except the light-producing reactions, have not been well investigated for physical principles and engineering biomimetics. Here we report a unique observation of high-transmission nanostructures on a firefly lantern and its biological inspiration for highly efficient LED illumination. Both numerical and experimental results clearly reveal high transmission through the nanostructures inspired from the lantern cuticle. The nanostructures on an LED lens surface were fabricated by using a large-area nanotemplating and reconfigurable nanomolding with heat-induced shear thinning. The biologically inspired LED lens, distinct from a smooth surface lens, substantially increases light transmission over visible ranges, comparable to conventional antireflection coating. This biological inspiration can offer new opportunities for increasing the light extraction efficiency of high-power LED packages. PMID:23112185

  4. Developing a new supplemental lighting device with ultra-bright white LED for vegetables

    NASA Astrophysics Data System (ADS)

    Hu, Yongguang; Li, Pingping; Jiang, Jianghai

    2007-02-01

    It has been proved that monochromatic or compound light-emitting diode (LED) or laser diode (LD) can promote the photosynthesis of horticultural crops, but the promotion of polychromatic light like white LED is unclear. A new type of ultra-bright white LED (LUW56843, InGaN, \

  5. Spatial layout optimization design of multi-type LEDs lighting source based on photoelectrothermal coupling theory

    NASA Astrophysics Data System (ADS)

    Xue, Lingyun; Li, Guang; Chen, Qingguang; Rao, Huanle; Xu, Ping

    2018-03-01

    Multiple LED-based spectral synthesis technology has been widely used in the fields of solar simulator, color mixing, and artificial lighting of plant factory and so on. Generally, amounts of LEDs are spatially arranged with compact layout to obtain the high power density output. Mutual thermal spreading among LEDs will produce the coupled thermal effect which will additionally increase the junction temperature of LED. Affected by the Photoelectric thermal coupling effect of LED, the spectrum of LED will shift and luminous efficiency will decrease. Correspondingly, the spectral synthesis result will mismatch. Therefore, thermal management of LED spatial layout plays an important role for multi-LEDs light source system. In the paper, the thermal dissipation network topology model considering the mutual thermal spreading effect among the LEDs is proposed for multi-LEDs system with various types of power. The junction temperature increment cased by the thermal coupling has the great relation with the spatial arrangement. To minimize the thermal coupling effect, an optimized method of LED spatial layout for the specific light source structure is presented and analyzed. The results showed that layout of LED with high-power are arranged in the corner and low-power in the center. Finally, according to this method, it is convenient to determine the spatial layout of LEDs in a system having any kind of light source structure, and has the advantages of being universally applicable to facilitate adjustment.

  6. Comparative effectiveness of light emitting diodes (LEDs) and Lasers in near infrared photoimmunotherapy

    PubMed Central

    Sato, Kazuhide; Watanabe, Rira; Hanaoka, Hirofumi; Nakajima, Takahito; Choyke, Peter L.; Kobayashi, Hisataka

    2016-01-01

    Near infrared photoimmunotherapy (NIR-PIT) is a new cancer treatment that combines the specificity of antibodies for targeting tumors with the toxicity induced by photosensitizers after exposure to near infrared (NIR) light. Herein we compare two NIR-light sources; light emitting diodes (LEDs) and Lasers, for their effectiveness in NIR-PIT. A photosensitizer, IRDye-700DX, conjugated to panitumumab (pan-IR700), was incubated with EGFR-expressing A431 and MDA-MB-468-luc cells. NIR-light was provided by LEDs or Lasers at the same light dose. Laser-light produced more cytotoxicity and greater reductions in IR700-fluorescence intensity than LED-light. Laser-light also produced more cytotoxicity in vivo in both cell lines. Assessment of super-enhanced permeability and retention (SUPR) effects were stronger with Laser than LED. These results suggest that Laser-light produced significantly more cytotoxic effects compared to LEDs. Although LED is less expensive, Laser-light produces superior results in NIR-PIT. PMID:26885688

  7. Comparative effectiveness of light emitting diodes (LEDs) and Lasers in near infrared photoimmunotherapy.

    PubMed

    Sato, Kazuhide; Watanabe, Rira; Hanaoka, Hirofumi; Nakajima, Takahito; Choyke, Peter L; Kobayashi, Hisataka

    2016-03-22

    Near infrared photoimmunotherapy (NIR-PIT) is a new cancer treatment that combines the specificity of antibodies for targeting tumors with the toxicity induced by photosensitizers after exposure to near infrared (NIR) light. Herein we compare two NIR-light sources; light emitting diodes (LEDs) and Lasers, for their effectiveness in NIR-PIT. A photosensitizer, IRDye-700DX, conjugated to panitumumab (pan-IR700), was incubated with EGFR-expressing A431 and MDA-MB-468-luc cells. NIR-light was provided by LEDs or Lasers at the same light dose. Laser-light produced more cytotoxicity and greater reductions in IR700-fluorescence intensity than LED-light. Laser-light also produced more cytotoxicity in vivo in both cell lines. Assessment of super-enhanced permeability and retention (SUPR) effects were stronger with Laser than LED. These results suggest that Laser-light produced significantly more cytotoxic effects compared to LEDs. Although LED is less expensive, Laser-light produces superior results in NIR-PIT.

  8. Application of the light emitting diodes (LEDs) in optical measurements

    NASA Astrophysics Data System (ADS)

    Sabinin, Vladimir E.; Savelyev, Sergey K.; Solk, Sergey V.

    2003-06-01

    At current moment the Light Emitting Diodes (LED) have found a great amount of applications in different areas -- for location and communication systems, optical information systems, in architecture light decoration and advertising, traffic signals, etc. In current work we are making attempt to analyze some new possible fields of LED application. Among these may be build in systems of photometry control. Many different optic and optoelectronic systems are in need of such devices, able to operate for a long time in an autonomous regime. LED's and especially optocouples on their base can provide required time stability and spectral characteristics. The main drawback of such elements is the particularity of the emission diagram. In many case it has unpredictable form, but high reliability and very simple design may compensate many of LED's drawbacks. Below are analyzed the optical schemes enabling transformation of the semiconductor crystal in visible and IR ranges into the beams with angular divergence of 2 degrees. From one crystal, having diameter less than 1 mm was gained the axial light power exceeding 1000 cd and it is possible to form the light sources providing light power up to 50 - 100 W/str. If to take into account that LED have narrow spectral band and high stability of this spectral band, their small dimensions, rather high efficiency, a possibility of intensity modulation by supply current it is very promising to apply these devices for system of buid in control. Such possibility was not realized in full up till now.

  9. Effect of LED phototherapy on blood lactate level in Taekwondo contest

    NASA Astrophysics Data System (ADS)

    Park, H. C.; Lee, B. K.; Lee, S. J.; Lim, S.

    2017-02-01

    The effect of LED phototherapy on blood lactate level in the muscle was studied. A 450cm2 large red and near infrared LED pad with its irradiance of 10mW/cm2 was applied for 10 minutes to brachial muscle and quadriceps muscle of thigh to the participants before and after the Taekwondo contest. Blood samples from the participants were taken at 5 minutes after the competition and 10 minutes after the recovery. The test results showed that the LED therapy (LEDT) before and after the competition had a significant effect on the decrease of blood lactate level of the participants.

  10. Effect of LED light stimulation on sleep latency in night shift people

    NASA Astrophysics Data System (ADS)

    Wu, Jih-Huah; Chang, Yang-Chyuan; Chiu, Hui-Ling; Fang, Wei; Shan, Yi-Chia; Chen, Ming-Jie; Chang, Yu-Ting

    2014-05-01

    Sleep problems are getting worse and worse in modern world. They have a severe impact on psychological and physical health, as well as social performances. From our previous study, the brainwave α rhythm, θ wave and β wave were affected by radiating the palm of the subjects with low-level laser array. In addition, from other study, the LED array stimulator (LEDAS) also has the similar effects. In the present study, LED light was used to radiate the left palm of the subjects too, and the effects were assessed with the multiple sleep latency test (MSLT) and heart-rate variability (HRV) analysis. The results revealed that it doesn't have significant meaning between these two groups. However, the tendency of the sleep latency (SL) in the LED group was shorter than that in the control group. In addition, the autonomic nervous system (ANS) analysis showed that the sympathetic nervous system was getting larger in the LED group than that in the control group, and total ANS activity were mainly getting larger in the LED group. We infer that this LED stimulation could reduce SL and balance ANS activity of the night-shift people. In the future, the further study will be conducted on normal subjects.

  11. Effects of pitch and shape for diffraction grating in LED fog lamp

    NASA Astrophysics Data System (ADS)

    Chen, Hsi-Chao; Lin, Jun-Yu; Wu, Jih-Huah; Ma, Shih-Hsin; Yang, Chi-Hao

    2011-10-01

    The characteristics of light-emitting diodes (LEDs) that make them energy-efficient and long-lasting light source for general illumination have attracted a great attention from the lighting industry and commercial market. As everyone know LEDs have the advantages of environmental protection, long lifetime, fast response time (μs), low voltage and good mechanical properties. Their high luminance and the wide region of the dominant wavelengths within the entire visible spectrum mean that people have high anticipations for the applications of LEDs. The output lighting from reflector in the traditional fog lamp was required to fit the standard of the ECE R19 F3 regulation. Therefore, this study investigated the effects of pitch and angle for a diffraction grating in LED fog lamp. The light pattern of fog lamp must be satisfied ECE regulations, so a design of diffraction grating to shift down the lighting was required. There are three LEDs (Cree XLamp XPE LEDs) as the light source in the fog lamp for the illumination efficiency. Then, an optimal simulation of diffraction grating was done for the pitch and angle of the diffraction grating at the test distance of 25 meters. The best pitch and angle was 2mm and 60 degree for the grating shape of wedge type.

  12. Improving “color rendering” of LED lighting for the growth of lettuce

    NASA Astrophysics Data System (ADS)

    Han, Tao; Vaganov, Vitaliy; Cao, Shixiu; Li, Qiang; Ling, Lili; Cheng, Xiaoyao; Peng, Lingling; Zhang, Congzhi; Yakovlev, Alexey N.; Zhong, Yang; Tu, Mingjing

    2017-04-01

    Light plays a vital role on the growth and development of plant. On the base of white light with high color rendering to the benefit of human survival and life, we proposed to improve “color rendering” of LED lighting for accelerating the growth of lettuce. Seven spectral LED lights were adopted to irradiate the lettuces under 150 μmol·m-2·s-1 for a 16 hd-1 photoperiod. The leaf area and number profiles, plant biomass, and photosynthetic rate under the as-prepared LED light treatments were investigated. We let the absorption spectrum of fresh leaf be the emission spectrum of ideal light and then evaluate the “color rendering” of as-prepared LED lights by the Pearson product-moment correlation coefficient and CIE chromaticity coordinates. Under the irradiation of red-yellow-blue light with high correlation coefficient of 0.587, the dry weights and leaf growth rate are 2-3 times as high as the sharp red-blue light. The optimized LED light for lettuce growth can be presumed to be limited to the angle (about 75°) between the vectors passed through the ideal light in the CIE chromaticity coordinates. These findings open up a new idea to assess and find the optimized LED light for plant growth.

  13. Cap- and initiator tRNA-dependent initiation of TYMV polyprotein synthesis by ribosomes: evaluation of the Trojan horse model for TYMV RNA translation.

    PubMed

    Matsuda, Daiki; Dreher, Theo W

    2007-01-01

    Turnip yellow mosaic virus (TYMV) RNA directs the translation of two overlapping open reading frames. Competing models have been previously published to explain ribosome access to the downstream polyprotein cistron. The Trojan horse model, based on cell-free experiments, proposes noncanonical cap-independent initiation in which the 3'-terminal tRNA-like structure (TLS) functionally replaces initiator tRNA, and the valine bound to the TLS becomes cis-incorporated into viral protein. The initiation coupling model, based on in vivo expression and ribosome toe-printing studies, proposes a variation of canonical leaky scanning. Here, we have re-examined the wheat germ extract experiments that led to the Trojan horse model, incorporating a variety of controls. We report that (1) translation in vitro from the polyprotein AUG of TYMV RNA is unchanged after removal of the 3' TLS but is stimulated by the presence of a 5'-cap; (2) the presence of free cap analog or edeine (which interferes with initiation at the ribosomal P site and its tRNA(i) (Met) involvement) inhibits translation from the polyprotein AUG; (3) the toe-prints of immediately post-initiation ribosomes on TYMV RNA are similar with and without an intact TLS; and (4) significant deacylation of valyl-TYMV RNA in wheat germ extract can complicate the detection of cis-incorporation. These results favor the initiation coupling model.

  14. Cap- and initiator tRNA-dependent initiation of TYMV polyprotein synthesis by ribosomes: Evaluation of the Trojan horse model for TYMV RNA translation

    PubMed Central

    Matsuda, Daiki; Dreher, Theo W.

    2007-01-01

    Turnip yellow mosaic virus (TYMV) RNA directs the translation of two overlapping open reading frames. Competing models have been previously published to explain ribosome access to the downstream polyprotein cistron. The Trojan horse model, based on cell-free experiments, proposes noncanonical cap-independent initiation in which the 3′-terminal tRNA-like structure (TLS) functionally replaces initiator tRNA, and the valine bound to the TLS becomes cis-incorporated into viral protein. The initiation coupling model, based on in vivo expression and ribosome toe-printing studies, proposes a variation of canonical leaky scanning. Here, we have re-examined the wheat germ extract experiments that led to the Trojan horse model, incorporating a variety of controls. We report that (1) translation in vitro from the polyprotein AUG of TYMV RNA is unchanged after removal of the 3′ TLS but is stimulated by the presence of a 5′-cap; (2) the presence of free cap analog or edeine (which interferes with initiation at the ribosomal P site and its tRNAi Met involvement) inhibits translation from the polyprotein AUG; (3) the toe-prints of immediately post-initiation ribosomes on TYMV RNA are similar with and without an intact TLS; and (4) significant deacylation of valyl-TYMV RNA in wheat germ extract can complicate the detection of cis-incorporation. These results favor the initiation coupling model. PMID:17095542

  15. Efficient calculation of luminance variation of a luminaire that uses LED light sources

    NASA Astrophysics Data System (ADS)

    Goldstein, Peter

    2007-09-01

    Many luminaires have an array of LEDs that illuminate a lenslet-array diffuser in order to create the appearance of a single, extended source with a smooth luminance distribution. Designing such a system is challenging because luminance calculations for a lenslet array generally involve tracing millions of rays per LED, which is computationally intensive and time-consuming. This paper presents a technique for calculating an on-axis luminance distribution by tracing only one ray per LED per lenslet. A multiple-LED system is simulated with this method, and with Monte Carlo ray-tracing software for comparison. Accuracy improves, and computation time decreases by at least five orders of magnitude with this technique, which has applications in LED-based signage, displays, and general illumination.

  16. From the Provider-Led to an Employer-Led System: Implications of Apprenticeship Reform on the Private Training Market

    ERIC Educational Resources Information Center

    Chankseliani, Maia; Relly, Susan James

    2015-01-01

    Despite expending a great deal of public money, and after many government-led "reforms" to develop an apprenticeship system that rivals those found in other countries, the apprenticeship system in England still faces a number of challenges and failings, not least in the private training market. This paper explores the landscape of…

  17. Student-led intervention to inNOvate hand hygiene practice in Auckland Region's medical students (the No HHARMS study).

    PubMed

    Lucas, Nathanael Cc; Hume, Carl G; Al-Chanati, Abdal; Diprose, William; Roberts, Sally; Freeman, Josh; Mogol, Vernon; Hoskins, David; Hamblin, Richard; Frampton, Chris; Bagg, Warwick; Merry, Alan F

    2017-01-13

    Hand hygiene is important in reducing healthcare-associated infections. The World Health Organization has defined 'five moments' when hand hygiene compliance is required. During 2013, New Zealand national data showed poor compliance with these moments by medical students. To improve medical students' compliance with the five moments. In this prospective student-led quality improvement initiative, student investigators developed, implemented and evaluated a multi-modal intervention comprising a three-month social media campaign, a competition and an entertaining educational video. Data on individual patient-medical student interactions were collected covertly by observers at baseline and at one week, six weeks and three months after initiation of the intervention. During the campaign, compliance improved in moment 2, but not significantly in moments 1, 3, 4 or 5. Statistical analysis of amalgamated data was limited by non-independent data points-a consideration apparently not always addressed in previous studies. The initiative produced improvements in compliance by medical students with one hand hygiene moment. Statistical analysis of amalgamated data for all five moments should allow for the non-independence of each occasion in which clinicians interact with a patient. More work is needed to ensure excellent hand hygiene practices of future doctors.

  18. Development and future of ultraviolet light-emitting diodes: UV-LED will replace the UV lamp

    NASA Astrophysics Data System (ADS)

    Muramoto, Yoshihiko; Kimura, Masahiro; Nouda, Suguru

    2014-06-01

    Ultraviolet light-emitting diodes (UV-LEDs) have started replacing UV lamps. The power per LED of high-power LED products has reached 12 W (14 A), which is 100 times the values observed ten years ago. In addition, the cost of these high-power LEDs has been decreasing. In this study, we attempt to understand the technologies and potential of UV-LEDs.

  19. LED lighting increases the ecological impact of light pollution irrespective of color temperature.

    PubMed

    Pawson, S M; Bader, M K-F

    Recognition of the extent and magnitude of night-time light pollution impacts on natural ecosystems is increasing, with pervasive effects observed in both nocturnal and diurnal species. Municipal and industrial lighting is on the cusp of a step change where energy-efficient lighting technology is driving a shift from “yellow” high-pressure sodium vapor lamps (HPS) to new “white” light-emitting diodes (LEDs). We hypothesized that white LEDs would be more attractive and thus have greater ecological impacts than HPS due to the peak UV-green-blue visual sensitivity of nocturnal invertebrates. Our results support this hypothesis; on average LED light traps captured 48% more insects than were captured with light traps fitted with HPS lamps, and this effect was dependent on air temperature (significant light × air temperature interaction). We found no evidence that manipulating the color temperature of white LEDs would minimize the ecological impacts of the adoption of white LED lights. As such, large-scale adoption of energy-efficient white LED lighting for municipal and industrial use may exacerbate ecological impacts and potentially amplify phytosanitary pest infestations. Our findings highlight the urgent need for collaborative research between ecologists and electrical engineers to ensure that future developments in LED technology minimize their potential ecological effects.

  20. Dimming LEDs with Phase-Cut Dimmers: The Specifier's Process for Maximizing Success

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Naomi J.; Poplawski, Michael E.

    2013-10-01

    This report reviews how phase-cut dimmers work, how LEDs differ from the incandescent lamps that the dimmers were historically designed to control, and how these differences can lead to complications when trying to dim LEDs. Compatibility between a specific LED source and a specific phase-cut dimmer is often unknown and difficult to assess, and ensuring compatibility adds complexity to the design, specification, bidding, and construction observation phases for new buildings and major remodel projects. To maximize project success, this report provides both general guidance and step-by-step procedures for designing phase-controlled LED dimming on both new and existing projects, as wellmore » as real-world examples of how to use those procedures.« less

  1. Optical CAD Utilization for the Design and Testing of a LED Streetlamp.

    PubMed

    Jafrancesco, David; Mercatelli, Luca; Fontani, Daniela; Sansoni, Paola

    2017-08-24

    The design and testing of LED lamps are vital steps toward broader use of LED lighting for outdoor illumination and traffic signalling. The characteristics of LED sources, in combination with the need to limit light pollution and power consumption, require a precise optical design. In particular, in every step of the process, it is important to closely compare theoretical or simulated results with measured data (obtained from a prototype). This work examines the various possibilities for using an optical CAD (Lambda Research TracePro ) to design and check a LED lamp for outdoor use. This analysis includes the simulations and testing on a prototype as an example; data acquired by measurement are inserted into the same simulation software, making it easy to compare theoretical and actual results.

  2. Fluorescent protein integrated white LEDs for displays

    NASA Astrophysics Data System (ADS)

    Press, Daniel Aaron; Melikov, Rustamzhon; Conkar, Deniz; Nur Firat-Karalar, Elif; Nizamoglu, Sedat

    2016-11-01

    The usage time of displays (e.g., TVs, mobile phones, etc) is in general shorter than their functional life time, which worsens the electronic waste (e-waste) problem around the world. The integration of biomaterials into electronics can help to reduce the e-waste problem. In this study, we demonstrate fluorescent protein integrated white LEDs to use as a backlight source for liquid crystal (LC) displays for the first time. We express and purify enhanced green fluorescent protein (eGFP) and monomeric Cherry protein (mCherry), and afterward we integrate these proteins as a wavelength-converter on a blue LED chip. The protein-integrated backlight exhibits a high luminous efficacy of 248 lm/Wopt and the area of the gamut covers 80% of the NTSC color gamut. The resultant colors and objects in the image on the display can be well observed and distinguished. Therefore, fluorescent proteins show promise for display applications.

  3. Studying Light Color using White LED Lighting

    NASA Astrophysics Data System (ADS)

    Yamagishi, Misako; Yamaba, Kazuo; Nagata, Manori; Kubo, Chiho; Nokura, Kunihiro

    Recently, white Light Emitting Diodes (LEDs) are receiving attention worldwide as new lighting devices. This study examined effects of a lighting application on performance using white LEDs. The light color—the correlated color temperature (CCT) —was assessed. It affected to psychological states and physiological conditions. Three CCT conditions were respectively set for the experiment: 2500 K, 5000 K, and 8200 K. In all, 20 younger subjects (20-30 years old), 15 middle-aged to elderly subjects (45-60 years old) and 12 elderly subjects (over 65 years-old) participated. They were presented a Numerical Verification (NV) task for performance measurement. The psychological states on performance were evaluated using the lighting assessment questionnaire. The physiological conditions were recorded using an electrocardiograph. Results show that the effects of CCT differ among age groups. Especially, the performance of younger subjects might differ from CCT conditions; elderly subjects are affected by CCT condition because of their visual acuity or response to contrast of objects.

  4. Effect of LED irradiation on the ripening and nutritional quality of postharvest banana fruit.

    PubMed

    Huang, Jen-Yi; Xu, Fengying; Zhou, Weibiao

    2018-04-24

    With the ability to tailor wavelengths necessary to the photosynthetically active radiation spectrum of plant pigments, light-emitting diodes (LEDs) offer vast possibilities in horticultural lighting. The influence of LED light irradiation on major postharvest features of banana was investigated. Mature green bananas were treated daily with selected blue (464-474 nm), green (515-525 nm) and red (617-627 nm) LED lights for 8 days, and compared with non-illuminated control. The positive effect of LED lighting on the acceleration of ripening in bananas was greatest for blue, followed by red and green. Under the irradiation of LED lights, faster peel de-greening and flesh softening, and increased ethylene production and respiration rate in bananas were observed during storage. Furthermore, the accumulations of ascorbic acid, total phenols, and total sugars in banana fruit were enhanced by LED light exposure. LED light treatment can induce the ripening of bananas and improve their quality and nutrition potential. These findings might provide new chemical-free strategies to shorten the time to ripen banana after harvest by using LED light source. This article is protected by copyright. All rights reserved.

  5. The impact of peer-led simulations on student nurses.

    PubMed

    Valler-Jones, Tracey

    Simulation within nurse education has been widely accepted as an educational approach. However, this is mainly led by the facilitator with the student maintaining a passive role in the learning. This paper describes a study that was undertaken to analyse the effectiveness of peer-led simulations in the undergraduate nursing programme. A mixed-method approach was used for this study design. This study took place in a simulation suite within a university in the Midlands. Twenty four second-year child branch students were purposively selected to take part. Students designed and facilitated a simulation based on the care of a critically ill child. Formal assessment of the learning was collected via the use of a structured clinical examination. Students completed an evaluation of their perceived confidence and competence levels. There was 100% pass rate in the assessment of students' clinical competence following the simulation. Thematic analysis of the evaluation highlighted the learning achieved by the students, not only of their clinical skills but also their personal development. The use of peer-led simulation promotes new learning and is a valuable educational approach.

  6. Application of high-brightness LEDs in aircraft position lights

    NASA Astrophysics Data System (ADS)

    Machi, Nicolo; Mangum, Scott; Singer, Jeffrey M.

    2004-10-01

    Solid state lighting devices have made their way into a number of niche markets and continue to make inroads into other markets as their price / performance ratios improve. One of these markets is aviation lighting. Although this paper will focus on the use of LEDs for aircraft position lights, much of the discussion is applicable to other installations on the interior and exterior of the aircraft. The color, light distribution and intensity levels for a position light are all closely regulated through Code of Federal Regulation (CFR; formerly Federal Aviation Regulation (FAR)) documents. These lighting requirements, along with harsh thermal and environmental requirements, drive the design. In this paper, we will look at these requirements and discuss what is required in order to use LEDs for this type of application. We will explore the optical, thermal and electrical issues associated with the use of LEDs for position lights and examine the specific case study of the Astreon forward position lights. Finally, we will discuss some of the challenges that we see with solid state lighting in current and future aircraft applications.

  7. Fuselage mounted anti-collision lights utilizing high power LEDs

    NASA Astrophysics Data System (ADS)

    Lundberg, John; Machi, Nicolo; Mangum, Scott; Singer, Jeffrey

    2005-09-01

    As LEDs continue to improve in efficacy and total light output, they are increasingly finding their way in to new applications in the aviation industry as well as adjacent markets. One function that is particularly challenging and may reap substantial benefits from this new technology is the fuselage mounted anti-collision light. Anti-collision lights provide conspicuity for the aircraft by periodically emitting bright flashes of light. The color, light distribution and intensity levels for these lights are all closely regulated through Federal Aviation Regulation (FAR) documents. These lighting requirements, along with thermal, environmental and aerodynamic requirements, drive the overall design. In this paper, we will discuss the existing technologies used in anti-collision lights and the advantages and challenges associated with an LED solution. Particular attention will be given to the optical, thermal, electrical and aerodynamic aspects associated with an LED approach. A specific case study will be presented along with some of the challenges that have arisen during the design process. These challenges include the addition of an integrated covert anti-collision lighting.

  8. Directed self-assembly of mesoscopic components for led applications

    NASA Astrophysics Data System (ADS)

    Tkachenko, Anton

    Light-emitting diodes (LEDs) constitute a rapidly evolving and fast growing technology that promises to replace incandescent bulbs and compact fluorescent lights in many illumination applications. Large-area LED luminaires have a capability to transform lighting by providing a venue for development of smart lighting systems with additional benefits, such as visible light communications, sensing, health and productivity improvement through color temperature control, capability of creating "virtual sky" ceiling, and many others. The objective of this work is to explore directed self-assembly (DSA) approaches suitable for cost-effective assembly of large amount of LEDs and other mesoscopic (i.e. millimeter and sub-millimeter) electronic components and thus to enable manufacturing of smart lighting luminaires. Existing alternative approaches for assembly of semiconductor dies are examined including transfer printing, laser-assisted die transfer, and various directed self-assembly approaches using shape-recognition, magnetic and capillary forces, etc. After comparing their advantages and limitations, we developed two approaches to magnetic force-assisted DSA of LEDs on a large-area substrate in liquid and air medium. The first approach involves pick-up of buoyant and magnetic dies from the liquid surface onto the flexible substrate in a roll-to-roll process. The possibility of high-speed assembly of LED dies is demonstrated, but with a low yield due to the influence of the capillary force of the carrier liquid and the difficulty in ensuring reliable supply of dies to the assembly interface. To overcome the aforementioned challenges this process was modified to assemble the dies by sinking them onto the receiving substrate with a stencil mask on top, demonstrating LED assembly with a very low error rate but at a lower speed. A solder-assisted self-alignment is used to further improve placement precision and to ensure the proper orientation of the dies. The second

  9. Investigation of Light-Emitting Diode (LED) Point Light Source Color Visibility against Complex Multicolored Backgrounds

    DTIC Science & Technology

    2017-11-01

    sent from light-emitting diodes (LEDs) of 5 colors ( green , red, white, amber, and blue). Experiment 1 involved controlled laboratory measurements of...A-4 Red LED calibration curves and quadratic curve fits with R2 values . 37 Fig. A-5 Green LED calibration curves and quadratic curve fits with R2...36 Table A-4 Red LED calibration measurements ................................................... 36 Table A-5 Green LED

  10. Total Synthesis of (±)–Rocaglamide via Oxidation-Initiated Nazarov Cyclization

    PubMed Central

    Malona, John A.; Cariou, Kevin; Spencer, William T.

    2012-01-01

    This article describes the evolution of a Nazarov cyclization-based synthetic strategy targeting the anticancer, antiinflammatory, and insecticidal natural product (±)–rocaglamide. Initial pursuit of a polarized heteroaromatic Nazarov cyclization to construct the congested cyclopentane core revealed an unanticipated electronic bias in the pentadienyl cation. This reactivity was harnessed in a successful second-generation approach using an oxidation-initiated Nazarov cyclization of a heteroaryl alkoxyallene. Full details of these two approaches are given, as well as the characterization of undesired reaction pathways available to the Nazarov cyclization product. A sequence of experiments that led to an understanding of the unexpected reactivity of this key intermediate is described, which culminated in the successful total synthesis of (+)-rocaglamide. PMID:22283818

  11. Power management of direct-view LED backlight for liquid crystal display

    NASA Astrophysics Data System (ADS)

    Lee, Xuan-Hao; Lin, Che-Chu; Chang, Yu-Yu; Chen, He-Xiang; Sun, Ching-Cherng

    2013-03-01

    In this paper, we present a study of management of power in function of luminous efficacy of white LED as well as the efficiency enhancement of the direct-view backlight with photon recycling. A cavity efficiency as high as 90.7% is demonstrated for a direct-view backlight with photon recycling. In the future, with a 90% backlight cavity, luminous efficacy of 200 lm/W for white LEDs, and a transmission efficiency of 10% for the liquid crystal panel, the required power of LEDs could be only 16 W. Up to 85% energy saving could be achieved in comparison to the power of the current liquid crystal display.

  12. Hybrid sunlight/LED illumination and renewable solar energy saving concepts for indoor lighting.

    PubMed

    Tsuei, Chih-Hsuan; Sun, Wen-Shing; Kuo, Chien-Cheng

    2010-11-08

    A hybrid method for using sunlight and light-emitting diode (LED) illumination powered by renewable solar energy for indoor lighting is simulated and presented in this study. We can illuminate an indoor space and collect the solar energy using an optical switching system. When the system is turned off, the full spectrum of the sunlight is concentrated by a concentrator, to be absorbed by solar photovoltaic devices that provide the electricity to power the LEDs. When the system is turned on, the sunlight collected by the concentrator is split into visible and non-visible rays by a beam splitter. The visible rays pass through the light guide into a light box where it is mixed with LED light to ultimately provide uniform illumination by a diffuser. The non-visible rays are absorbed by the solar photovoltaic devices to provide electrical power for the LEDs. Simulation results show that the efficiency of the hybrid sunlight/LED illumination with the renewable solar energy saving design is better than that of LED and traditional lighting systems.

  13. YAG glass-ceramic phosphor for white LED (II): luminescence characteristics

    NASA Astrophysics Data System (ADS)

    Tanabe, Setsuhisa; Fujita, Shunsuke; Yoshihara, Satoru; Sakamoto, Akihiko; Yamamoto, Shigeru

    2005-09-01

    Optical properties of the Ce:YAG glass-ceramic (GC) phosphor for the white LED were investigated. Concentration dependence of fluorescence intensity of Ce3+:5d→4f transition in the GC showed a maximum at 0.5mol%Ce2O3. Quantum efficiency (QE) of Ce3+ fluorescence in the GC materials, the color coordinate and luminous flux of electroluminescence of LED composite were evaluated with an integrating sphere. QE increased with increasing ceramming temperature of the as-made glass. The color coordinates (x,y) of the composite were increased with increasing thickness of the GC mounted on a blue LED chip. The effect of Gd2O3 substitution on the optical properties of the GC materials was also investigated. The excitation and emission wavelength shifted to longer side up to Gd/(Y+Gd)=0.40 in molar composition. As a result, the color coordinate locus of the LED with various thickness of the GdYAG-GC shifted to closer to the Planckian locus for the blackbody radiation. These results were explained by partial substitution of Gd3+ ions in the precipitated YAG micro-crystals, leading to the increase of lattice constant of unit cell, which was confirmed by X-ray diffraction.

  14. Raman study of the effect of LED light on grafted bone defects

    NASA Astrophysics Data System (ADS)

    Soares, Luiz G. G. P.; Aciole, Jouber M. S.; Aciole, Gilbeth T. S.; Barbosa, Artur F. S.; Silveira-Júnior, Landulfo; Pinheiro, Antônio L. B.

    2013-03-01

    Benefits of the isolated or combined use light and biomaterials on bone healing have been suggested. Our group has used several models to assess the effects of laser on bone. A Raman spectral analysis on surgical bone defects grafted or not with Hydroxyapatite (HA), treated or not with LED was carried out. 40 rats were divided into 4 groups. On Group I the defect was filled with the clot. On Group II, the defect was filled with the HA. On groups III the defect was filled with Clot and further irradiated with LED and on group IV the defects was filled with the HA and further irradiated with LED. LED (λ850 +/- 10nm, 150mW, A= 0.5cm2, 68s, 20 J/cm2 per session, 140 J/cm2 per treatment) was applied at 48 h intervals during 15 days. Specimens were taken after 15 and 30 days after surgery and kept on liquid nitrogen, and underwent Raman analysis. For this, the peak of hydroxyapatite (~960 cm-1) was used as marker of bone mineralization. Significant difference was observed at both times (p<0.05). When the biomaterial was used higher peaks were observed. Association with LED further improved the intensity. Conclusion: It is concluded that LED light improved the effect of the HA.

  15. Light-emitting diodes (LED) for domestic lighting: any risks for the eye?

    PubMed

    Behar-Cohen, F; Martinsons, C; Viénot, F; Zissis, G; Barlier-Salsi, A; Cesarini, J P; Enouf, O; Garcia, M; Picaud, S; Attia, D

    2011-07-01

    Light-emitting diodes (LEDs) are taking an increasing place in the market of domestic lighting because they produce light with low energy consumption. In the EU, by 2016, no traditional incandescent light sources will be available and LEDs may become the major domestic light sources. Due to specific spectral and energetic characteristics of white LEDs as compared to other domestic light sources, some concerns have been raised regarding their safety for human health and particularly potential harmful risks for the eye. To conduct a health risk assessment on systems using LEDs, the French Agency for Food, Environmental and Occupational Health & Safety (ANSES), a public body reporting to the French Ministers for ecology, for health and for employment, has organized a task group. This group consisted physicists, lighting and metrology specialists, retinal biologist and ophthalmologist who have worked together for a year. Part of this work has comprised the evaluation of group risks of different white LEDs commercialized on the French market, according to the standards and found that some of these lights belonged to the group risk 1 or 2. This paper gives a comprehensive analysis of the potential risks of white LEDs, taking into account pre-clinical knowledge as well as epidemiologic studies and reports the French Agency's recommendations to avoid potential retinal hazards. Copyright © 2011. Published by Elsevier Ltd.

  16. Researcher-Led Teaching: Embodiment of Academic Practice

    ERIC Educational Resources Information Center

    Hay, David; Weller, Saranne; Ashton, Kim

    2015-01-01

    This paper explores the embodied practices of leading researchers (and/or leading scholars/practitioners), suggesting that distinctive "researcher-led teaching" depends on educators who are willing and able to be their research in the teaching setting. We advocate an approach to the development of higher education pedagogy which makes…

  17. Effective recruitment of minority populations through community-led strategies.

    PubMed

    Horowitz, Carol R; Brenner, Barbara L; Lachapelle, Susanne; Amara, Duna A; Arniella, Guedy

    2009-12-01

    Traditional research approaches frequently fail to yield representative numbers of people of color in research. Community-based participatory research (CBPR) may be an important strategy for partnering with and reaching populations that bear a greater burden of illness but have been historically difficult to engage. The Community Action Board, consisting of 20 East Harlem residents, leaders, and advocates, used CBPR to compare the effectiveness of various strategies in recruiting and enrolling adults with prediabetes into a peer-led, diabetes prevention intervention. The board created five recruitment strategies: recruiting through clinicians; recruiting at large public events such as farmers markets; organizing special local recruitment events; recruiting at local organizations; and recruiting through a partner-led approach, in which community partners developed and managed the recruitment efforts at their sites. In 3 months, 555 local adults were approached; 249 were appropriate candidates for further evaluation (overweight, nonpregnant, East Harlem residents without known diabetes); 179 consented and returned in a fasting state for 1/2 day of prediabetes testing; 99 had prediabetes and enrolled in a pilot randomized trial. The partner-led approach was highly successful, recruiting 68% of those enrolled. This strategy was also the most efficient; 34% of those approached through partners were ultimately enrolled, versus 0%-17% enrolled through the other four strategies. Participants were predominantly low-income, uninsured, undereducated, Spanish-speaking women. This CBPR approach highlights the value of partner-led recruitment to identify, reach out to, and motivate a vulnerable population into participation in research, using techniques that may be unfamiliar to researchers but are nevertheless rigorous and effective.

  18. A novel solution for LED wall lamp design and simulation

    NASA Astrophysics Data System (ADS)

    Ge, Rui; Hong, Weibin; Li, Kuangqi; Liang, Pengxiang; Zhao, Fuli

    2014-11-01

    The model of the wall washer lamp and the practical illumination application have been established with a new design of the lens to meet the uniform illumination demand for wall washer lamp based on the Lambertian light sources. Our secondary optical design of freeform surface lens to LED wall washer lamp based on the conservation law of energy and Snell's law can improve the lighting effects as a uniform illumination. With the relationship between the surface of the lens and the surface of the target, a great number of discrete points of the freeform profile curve were obtained through the iterative method. After importing the data into our modeling program, the optical entity was obtained. Finally, to verify the feasibility of the algorithm, the model was simulated by specialized software, with both the LED Lambertian point source and LED panel source model.

  19. Spot fat reduction by red and near infrared LED phototherapy

    NASA Astrophysics Data System (ADS)

    Lim, Sungkyoo; Park, Eal-Whan

    2018-02-01

    Low level light therapy (LLLT) using light from red and near infrared LEDs or Lasers have been reported effective as noninvasive methods for reducing spot fat. A total of 55 subjects were randomly divided into test groups and control groups for abdominal fat reduction clinical trial using red and near infrared LED phototherapy devices. Red and near infrared light with irradiance of 10 mW/cm2 were irradiated over the abdominal area to the test group for 30 minutes followed by 30 minutes of aerobic exercise, 3 times a week for 4 weeks. Control group used sham devices for 30 minutes and followed by 30 minutes of aerobic exercise. It is expected that red and near infrared LED phototherapy combined with aerobic exercise would be effective and safe for abdominal fat reduction without any side effects.

  20. Large Igneous Provinces, Sulfur Aerosols, and Initiation of Snowball Earth

    NASA Astrophysics Data System (ADS)

    Macdonald, F. A.; Wordsworth, R. D.

    2015-12-01

    The events that led to the initiation of Snowball Earth remain poorly understood. Proposed scenarios include a methane addiction, a biological innovation that led to an increase in organic carbon burial and anaerobic remineralization, or an increase in global weatherability due to a paleogeography with a preponderance of low latitude continents, and the subareal implacement of large igneous provinces (LIPs) at the equator. The Franklin LIP was emplaced between 730 and 710 Ma and covers an area of over 2.25 Mkm2 with lavas, sills, and dikes extending over much of northern Laurentia from Alaska through northern Canada to Greenland and potentially to Siberia. The most precise geochronological constraints on the Franklin LIP overlap with the onset of the Sturtian Snowball Earth glaciation, which began between 717 and 716 Ma and marked the first glaciation in over 1 billion years. The Franklin LIP is the largest preserved Neoproterozoic LIP and one of the largest in Earth History. Additionally, it was emplaced at equatorial latitudes with associated sills that invaded epicontinental sulfur evaporite basins, potentially maximizing environmental effects. Here we explore the hypothesis that the Sturtian Snowball Earth was initiated in part by an increase in planetary albedo from the conversion of volcanic SO2/H2S emissions to tropospheric and stratospheric sulfate aerosols through a combination of geochemical and modeling studies.

  1. Development of High-power LED Lighting Luminaires Using Loop Heat Pipe

    NASA Astrophysics Data System (ADS)

    Huang, Bin-Juine; Huang, Huan-Hsiang; Chen, Chun-Wei; Wu, Min-Sheng

    High-power LED should reject about 6 times of heat of the conventional lighting device and keep the LED junction temperature below 80°C to assure reliability and low light decay. In addition, no fan is allowed and the heat dissipation design should not interfere with the industrial design of lighting fixture and have a light weight. This thus creates an extreme thermal management problem. The present study has shown that, using a special heat dissipation technology (loop heat pipe), the high-power LED lighting luminaire with input power from 36 to 150W for outdoor and indoor applications can be achieved with light weight, among 0.96 to 1.57 kg per 1,000 lumen of net luminous flux output from the luminaire. The loop heat pipe uses a flexible connecting pipe as the condenser which can be wounded around the reflector of the luminaire to dissipate the heat to the ambient air by natural convection. For roadway or street lighting application, the present study shows that a better optical design of LED lamps can further result in power consumption reduction, based on the same illumination on road surface. The high-power LED luminaries developed in the present study have shown that the energy saving is > 50% in road lighting applications as compared to sodium light or > 70% compared to mercury light.

  2. Inhibition of enamel remineralization with blue LED: an in vitro study

    NASA Astrophysics Data System (ADS)

    Kato, Ilka Tiemy; Mendes, Fausto Medeiros; Zezell, Denise Maria; Zanardi de Freitas, Anderson; Raele, Marcus Paulo; Wetter, Niklaus Ursus

    2009-02-01

    Blue light, especially from LED devices, is a tool very frequently used in dental procedures. However, the investigations of its effects on dental enamel are focused primarily on enamel demineralization and fluoride retention. Despite the fact that this spectral region can inhibit enamel demineralization, the consequences of the irradiation on demineralized enamel are not known. For this reason, we evaluated the effects of blue LED on enamel remineralization. Artificial lesions formed in bovine dental enamel samples by immersion in undersaturated acetate buffer were divided into three groups. In the first group (DE), the lesions were not submitted to any treatment. In the second (RE), the lesions were submitted to remineralization. The lesions from the third group (LED+RE) were irradiated with blue LED (455nm, 1.38W/cm2, 13.75J/cm2 and 10s) before the remineralization. Cross-sectional microhardness was used to assess mineral changes induced by remineralization under pH-cycling. The mineral deposition occurred preferably in the middle portion of the lesions. Specimens from group RE showed higher hardness value than the DE ones. On the other hand, the mean hardness value of the LED+RE samples was not statistically different from the DE samples. Results obtained in the present study show that the blue light is not innocuous for the dental enamel and inhibition of its remineralization can occur.

  3. Evaluation of an LED Retrofit Project at Princeton University's Carl Icahn Laboratory

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davis, Robert; Murphy, Arthur; Perrin, Tess

    At Princeton University’s Carl Icahn Laboratory, DOE’s Commercial Buildings Integration Program documented the implementation of LED retrofit products for recessed troffers, linear cove lighting, and downlights – as part of Princeton’s first building-wide interior LED project. The conversion to LED enables more extensive use of lighting controls to tailor the lighting to the task and limit the operating hours based on occupancy, and the estimated energy savings including controls is 62% compared to the incumbent system.

  4. Advances in LED packaging and thermal management materials

    NASA Astrophysics Data System (ADS)

    Zweben, Carl

    2008-02-01

    Heat dissipation, thermal stresses and cost are key light-emitting diode (LED) packaging issues. Heat dissipation limits power levels. Thermal stresses affect performance and reliability. Copper, aluminum and conventional polymeric printed circuit boards (PCBs) have high coefficients of thermal expansion, which can cause high thermal stresses. Most traditional low-coefficient-of-thermal-expansion (CTE) materials like tungsten/copper, which date from the mid 20th century, have thermal conductivities that are no better than those of aluminum alloys, about 200 W/m-K. An OIDA LED workshop cited a need for better thermal materials. There are an increasing number of low-CTE materials with thermal conductivities ranging between that of copper (400 W/m-K) and 1700 W/m-K, and many other low-CTE materials with lower thermal conductivities. Some of these materials are low cost. Others have the potential to be low cost in high-volume production. High-thermal-conductivity materials enable higher power levels, potentially reducing the number of required LEDs. Advanced thermal materials can constrain PCB CTE and greatly increase thermal conductivity. This paper reviews traditional packaging materials and advanced thermal management materials. The latter provide the packaging engineer with a greater range of options than in the past. Topics include properties, status, applications, cost, using advanced materials to fix manufacturing problems, and future directions, including composites reinforced with carbon nanotubes and other thermally conductive materials.

  5. A School-Wide Approach to Student-Led Conferences: A Practitioner's Guide.

    ERIC Educational Resources Information Center

    Kinney, Patti; Munroe, Mary Beth; Sessions, Pam

    Noting that the benefits of student-led conferences align well with practices recognized as developmentally appropriate for the middle school years, this book provides a step-by-step guide to implementing student-led conferences at the middle school level. The chapters are: (1) "Setting the Stage," presenting the rationale for student-led…

  6. Reducing Unnecessary Portable Pelvic Radiographs in Trauma Patients: A Resident-Driven Quality Improvement Initiative.

    PubMed

    Langer, Jessica M; Tsai, Emily B; Luhar, Aarti; McWilliams, Justin; Motamedi, Kambiz

    2015-09-01

    Quality improvement is increasingly important in the changing health care climate. We aim to establish a methodology and identify critical factors leading to successful implementation of a resident-led radiology quality improvement intervention at the institutional level. Under guidance of faculty mentors, the first-year radiology residents developed a quality improvement initiative to decrease unnecessary STAT pelvic radiographs (PXRs) in hemodynamically stable trauma patients who would additionally receive STAT pelvic CT scans. Development and implementation of this initiative required multiple steps, including: establishing resident and faculty leadership, gathering evidence from published literature, cultivating multidisciplinary support, and developing and implementing an institution-wide ordering algorithm. A visual aid and brief questionnaire were distributed to clinicians for use during treatment of trauma cases to ensure sustainability of the initiative. At multiple time points, pre- and post-intervention, residents performed a retrospective chart review to evaluate changes in imaging-ordering trends for trauma patients. Chart review showed a decline in the number of PXRs for hemodynamically stable trauma patients, as recommended in the ordering algorithm: 78% of trauma patients received both a PXR and a pelvic CT scan in the first 24 hours of the initiative, compared with 26% at 1 month; 24% at 6 months; and 18% at 10 to 12 months postintervention. The resident-led radiology quality improvement initiative created a shift in ordering culture at an institutional level. Development and implementation of this algorithm exemplified the impact of a multidisciplinary collaborative effort involving multiple departments and multiple levels of the medical hierarchy. Copyright © 2015 American College of Radiology. Published by Elsevier Inc. All rights reserved.

  7. Development of a method for the characterization and operation of UV-LED for water treatment.

    PubMed

    Kheyrandish, Ataollah; Mohseni, Madjid; Taghipour, Fariborz

    2017-10-01

    Tremendous improvements in semiconductor technology have made ultraviolet light-emitting diodes (UV-LEDs) a viable alternative to conventional UV sources for water treatment. A robust and validated experimental protocol for studying the kinetics of microorganism inactivation is key to the further development of UV-LEDs for water treatment. This study proposes a protocol to operate UV-LEDs and control their output as a polychromatic radiation source. In order to systematically develop this protocol, the results of spectral power distribution, radiation profile, and radiant power measurements of a variety of UV-LEDs are presented. A wide range of UV-LEDs was selected for this study, covering various UVA, UVB, and UVC wavelengths, viewing angles from 3.5° to 135°, and a variety of output powers. The effects of operational conditions and measurement techniques were investigated on these UV-LEDs using a specially designed and fabricated setup. Operating conditions, such as the UV-LED electrical current and solder temperature, were found to significantly affect the power and peak wavelength output. The measurement techniques and equipment, including the detector size, detector distance from the UV-LED, and potential reflection from the environment, were shown to influence the results for many of the UV-LEDs. The results obtained from these studies were analyzed and applied to the development of a protocol for UV-LED characterization. This protocol is presented as a guideline that allows the operation and control of UV-LEDs in any structure, as well as accurately measuring the UV-LED output. Such information is essential for performing a reliable UV-LED assessment for the inactivation of microorganisms and for obtaining precise kinetic data. Copyright © 2017 Elsevier Ltd. All rights reserved.

  8. Miniaturized LEDs for flat-panel displays

    NASA Astrophysics Data System (ADS)

    Radauscher, Erich J.; Meitl, Matthew; Prevatte, Carl; Bonafede, Salvatore; Rotzoll, Robert; Gomez, David; Moore, Tanya; Raymond, Brook; Cok, Ronald; Fecioru, Alin; Trindade, António Jose; Fisher, Brent; Goodwin, Scott; Hines, Paul; Melnik, George; Barnhill, Sam; Bower, Christopher A.

    2017-02-01

    Inorganic light emitting diodes (LEDs) serve as bright pixel-level emitters in displays, from indoor/outdoor video walls with pixel sizes ranging from one to thirty millimeters to micro displays with more than one thousand pixels per inch. Pixel sizes that fall between those ranges, roughly 50 to 500 microns, are some of the most commercially significant ones, including flat panel displays used in smart phones, tablets, and televisions. Flat panel displays that use inorganic LEDs as pixel level emitters (μILED displays) can offer levels of brightness, transparency, and functionality that are difficult to achieve with other flat panel technologies. Cost-effective production of μILED displays requires techniques for precisely arranging sparse arrays of extremely miniaturized devices on a panel substrate, such as transfer printing with an elastomer stamp. Here we present lab-scale demonstrations of transfer printed μILED displays and the processes used to make them. Demonstrations include passive matrix μILED displays that use conventional off-the shelf drive ASICs and active matrix μILED displays that use miniaturized pixel-level control circuits from CMOS wafers. We present a discussion of key considerations in the design and fabrication of highly miniaturized emitters for μILED displays.

  9. Melanoma: Genetic Abnormalities, Tumor Progression, Clonal Evolution and Tumor Initiating Cells.

    PubMed

    Testa, Ugo; Castelli, Germana; Pelosi, Elvira

    2017-11-20

    Melanoma is an aggressive neoplasia issued from the malignant transformation of melanocytes, the pigment-generating cells of the skin. It is responsible for about 75% of deaths due to skin cancers. Melanoma is a phenotypically and molecularly heterogeneous disease: cutaneous, uveal, acral, and mucosal melanomas have different clinical courses, are associated with different mutational profiles, and possess distinct risk factors. The discovery of the molecular abnormalities underlying melanomas has led to the promising improvement of therapy, and further progress is expected in the near future. The study of melanoma precursor lesions has led to the suggestion that the pathway of tumor evolution implies the progression from benign naevi, to dysplastic naevi, to melanoma in situ and then to invasive and metastatic melanoma. The gene alterations characterizing melanomas tend to accumulate in these precursor lesions in a sequential order. Studies carried out in recent years have, in part, elucidated the great tumorigenic potential of melanoma tumor cells. These findings have led to speculation that the cancer stem cell model cannot be applied to melanoma because, in this malignancy, tumor cells possess an intrinsic plasticity, conferring the capacity to initiate and maintain the neoplastic process to phenotypically different tumor cells.

  10. The design of optical module of LED street lamp with non-axial symmetrical reflector

    NASA Astrophysics Data System (ADS)

    Lu, Ming-Jun; Chen, Chi-An; Chen, Yi-Yung; Whang, Allen Jong-Woei

    2010-05-01

    In recently, many research focus on the LED applications for environmental protection so a number of LED street lamps are presented. Although LED has many advantages for environmental protection, its special optical characteristics, such as intensity distribution, always limit the advantages in many applications. Therefore, we always need to do the secondary optical design for LED street lamp to replace the traditional optical designs that are designed for high-pressure sodium lamps and mercury lamps. According to the situation, we design an optical module of LED street lamp with LEDs and secondary optical design. First, the LEDs are placed on freeform reflector for the specific illuminated conditions. We design the optical module of street lamp with the two conditions that include the uniformity and the ratio of length to width in the illuminated area and without any light pollution. According to the simulation with the designed optical module, the uniformity in the illuminated area is about 0.6 that is better than the general condition, 0.3, and the ratio of length to width in the illuminated area is 3:1 in which the length is 30 meters and the width is 10 meters. Therefore, the design could let LED street lamp fits the two conditions, uniformity and ratio in the illuminated area.

  11. Evaluation of the Potential Optical Radiation Hazards with Led Lamps Intended for Home Use.

    PubMed

    James, Robert H; Landry, Robert J; Walker, Bennett N; Ilev, Ilko K

    2017-01-01

    The authors evaluated the potential for ocular damage from optical radiation emitted by Light Emitting Diode (LED) based lamps used for general illumination. Ten LED lamps were randomly selected off the shelf from a local home improvement store. The LEDs were behind diffusers in half of these lamps, while in the other half, the LEDs were clearly visible. In addition, a battery powered LED lantern having a LED source behind a diffuser was measured. The optical radiation emissions from two common incandescent lamps were also measured to compare the relative hazards of LED and incandescent lamps. All lamp samples were evaluated in accordance with procedures specified in the American National Standards Institute/Illuminating Engineering Society of North America (ANSI/IESNA) Standard RP-27.3. For comparison purposes, the lantern and 100 W incandescent lamps were also evaluated according to ANSI RP-27.1. These measurements indicate that no lamp evaluated poses any photobiological hazard, and therefore, all lamps fall in the RP-27.3 category of Exempt Group. However, when evaluated in accordance with RP-27.1, the 100 W incandescent lamp would be classified in Risk Group 1 (low risk), while the LED lantern would be classified in Risk Group 2 (moderate risk).

  12. Initialization methods and ensembles generation for the IPSL GCM

    NASA Astrophysics Data System (ADS)

    Labetoulle, Sonia; Mignot, Juliette; Guilyardi, Eric; Denvil, Sébastien; Masson, Sébastien

    2010-05-01

    The protocol used and developments made for decadal and seasonal predictability studies at IPSL (Paris, France) are presented. The strategy chosen is to initialize the IPSL-CM5 (NEMO ocean and LMDZ atmosphere) model only at the ocean-atmosphere interface, following the guidance and expertise gained from ocean-only NEMO experiments. Two novel approaches are presented for initializing the coupled system. First, a nudging of sea surface temperature and wind stress towards available reanalysis is made with the surface salinity climatologically restored. Second, the heat, salt and momentum fluxes received by the ocean model are computed as a linear combination of the fluxes computed by the atmospheric model and by a CORE-style bulk formulation using up-to-date reanalysis. The steps that led to these choices are presented, as well as a description of the code adaptation and a comparison of the computational cost of both methods. The strategy for the generation of ensembles at the end of the initialization phase is also presented. We show how the technical environment of IPSL-CM5 (LibIGCM) was modified to achieve these goals.

  13. 77 FR 55186 - Executive-Led Indonesia Vietnam Infrastructure Business Development Mission Statement...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-07

    ... DEPARTMENT OF COMMERCE International Trade Administration Executive-Led Indonesia Vietnam... the Notice of the Executive-Led Indonesia Vietnam Infrastructure Business Development Mission... Timeframe for Recruitment and Applications section of the Notice of the Indonesia Vietnam Infrastructure...

  14. NREL-Led Effort Results in Groundbreaking New ASTM High-Octane Fuel

    Science.gov Websites

    Standard | News | NREL NREL-Led Effort Results in Groundbreaking New ASTM High-Octane Fuel Standard NREL-Led Effort Results in Groundbreaking New ASTM High-Octane Fuel Standard April 7, 2017 NREL . Photo by Dennis Schroeder, NREL 20114. ASTM International recently announced the release of a new high

  15. Inactivation of Escherichia coli on tomatoes using a ultraviolet(LED)light

    USDA-ARS?s Scientific Manuscript database

    The recently developed UV LED has been shown effective at inactivating bacteria in water, but its ability to inactivate bacteria on foods is unknown. Escherichia coli in solution and dried on the surface of tomatoes was exposed to 255 nm UV from a LED, with a forward voltage of 6.5 V operating at 20...

  16. Integrated aerobic biological-chemical treatment of winery wastewater diluted with urban wastewater. LED-based photocatalysis in the presence of monoperoxysulfate.

    PubMed

    Solís, Rafael R; Rivas, Francisco Javier; Ferreira, Leonor C; Pirra, Antonio; Peres, José A

    2018-01-28

    The oxidation of Winery Wastewater (WW) by conventional aerobic biological treatment usually leads to inefficient results due to the presence of organic substances, which are recalcitrant or toxic in conventional procedures. This study explores the combination of biological and chemical processes in order to complete the oxidation of biodegradable and non-biodegradable compounds in two sequential steps. Thus, a biological oxidation of a diluted WW is carried out by using the activated sludge process. Activated sludge was gradually acclimated to the Diluted Winery Wastewater (DWW). Some aspects concerning the biological process were evaluated (kinetics of the oxidation and sedimentation of the sludge produced). The biological treatment of the DWW led to a 40-50% of Chemical Oxygen Demand (COD) removal in 8 h, being necessary the application of an additional process. Different chemical processes combining UVA-LEDs radiation, monoperoxysulfate (MPS) and photocatalysts were applied in order to complete the COD depletion and efficient removal of polyphenols content, poorly oxidized in the previous biological step. From the options tested, the combination of UVA, MPS and a novel LaCoO 3 -TiO 2 composite, with double route of MPS decomposition through heterogeneous catalysis and photocatalysis, led to the best results (95% of polyphenol degradation, and additional 60% of COD removal). Initial MPS concentration and pH effect in this process were assessed.

  17. A wirelessly controlled implantable LED system for deep brain optogenetic stimulation

    PubMed Central

    Rossi, Mark A.; Go, Vinson; Murphy, Tracy; Fu, Quanhai; Morizio, James; Yin, Henry H.

    2015-01-01

    In recent years optogenetics has rapidly become an essential technique in neuroscience. Its temporal and spatial specificity, combined with efficacy in manipulating neuronal activity, are especially useful in studying the behavior of awake behaving animals. Conventional optogenetics, however, requires the use of lasers and optic fibers, which can place considerable restrictions on behavior. Here we combined a wirelessly controlled interface and small implantable light-emitting diode (LED) that allows flexible and precise placement of light source to illuminate any brain area. We tested this wireless LED system in vivo, in transgenic mice expressing channelrhodopsin-2 in striatonigral neurons expressing D1-like dopamine receptors. In all mice tested, we were able to elicit movements reliably. The frequency of twitches induced by high power stimulation is proportional to the frequency of stimulation. At lower power, contraversive turning was observed. Moreover, the implanted LED remains effective over 50 days after surgery, demonstrating the long-term stability of the light source. Our results show that the wireless LED system can be used to manipulate neural activity chronically in behaving mice without impeding natural movements. PMID:25713516

  18. Study on the mechanism of color coordinate shift of LED package

    NASA Astrophysics Data System (ADS)

    Zhuang, Yunyi; Wang, Yong; Yang, Bobo; Li, Zhanguo; Yang, Lei; Zou, Jun

    2017-07-01

    In the paper, the influences of the chip, silicone and phosphors on the color coordinate shift of LED were studied. In the process of LED baking, it was found that the effect of the chip and silicone on the color coordinate drift is less than 3% through the analysis of each influencing factor. But the influence of the phosphors is large and accounted for 11.11% of the overall impact factors. Therefore, it is important to select the better green phosphors in thermal stability for the LED package and it has a guiding significance to the color coordinate of LED distribution. Project supported by the National Natural Science Foundation of China (No. 11474036), the Natural Science Foundation of Shanghai (No. 12ZR1430900), the Shanghai Institute of Technology Talents Scheme (No. YJ2014-04), the Shanghai Municipal Alliance Program (Nos. Lm201514, Lm201505, Lm201455), the Science and Technology Commission of Shanghai Municipality (CN) (No. 14500503300), the Shanghai Cooperative Project (No. ShanghaiCXY-2013-61), and the Jiashan County Technology Program (No. 20141316).

  19. Global Health Initiatives of the International Oncology Community.

    PubMed

    Al-Sukhun, Sana; de Lima Lopes, Gilberto; Gospodarowicz, Mary; Ginsburg, Ophira; Yu, Peter Paul

    2017-01-01

    Cancer has become one of the leading causes of morbidity and mortality in low- and middle-income countries (LMICs), where 60% of the world's total new cases are diagnosed. The challenge for effective control of cancer is multifaceted. It mandates integration of effective cancer prevention, encouraging early detection, and utilization of resource-adapted therapeutic and supportive interventions. In the resource-constrained setting, it becomes challenging to deliver each service optimally, and efficient allocation of resources is the best way to improve the outcome. This concept was translated into action through development of resource-stratified guidelines, pioneered by the Breast Health Global Initiative (BHGI), and later adopted by most oncology societies in an attempt to help physicians deliver the best possible care in a limited-resource setting. Improving outcome entails collaboration between key stakeholders, including the pharmaceutical industry, local and national health authorities, the World Health Organization (WHO), and other nonprofit, patient-oriented organizations. Therefore, we started to observe global health initiatives-led by ASCO, the Union for International Cancer Control (UICC), and the WHO-to address these challenges at the international level. This article discusses some of these initiatives.

  20. NASA sponsored Light Emitting Diode (LED) development helps in cancer treatment

    NASA Technical Reports Server (NTRS)

    1997-01-01

    What started out as an attempt to develop a light which would allow for the growth of plants in space led to a remarkable discovery: The Light Emitting Diode (LED). This device through extensive study and experimentation has developed into a tool used by surgeons in the fight against brain cancer in children. Pictured is a mock-up of brain surgery being performed. By encapsulating the end of the LED with a balloon, light is diffused over a larger area of the brain allowing the surgeon a better view. This is one of many programs that begin as research for the space program, and through extensive study end up benefitting all of mankind.

  1. Nurse-led management of contraceptive services.

    PubMed

    Wilson, Emma

    2014-07-01

    This article discusses the role of the practice nurse (PN) in the provision of health assessment for contraceptive choices. PNs who have an extended role as an independent nurse prescriber must demonstrate the principles of safe prescribing practice, with appropriate and informed assessment of the patient's needs and risk within the limited time of a general practice appointment. With continued professional development, PNs are well placed to provide comprehensive, independent nurse-led contraceptive services.

  2. The Involvement of the Oxidative Stress in Murine Blue LED Light-Induced Retinal Damage Model.

    PubMed

    Nakamura, Maho; Kuse, Yoshiki; Tsuruma, Kazuhiro; Shimazawa, Masamitsu; Hara, Hideaki

    2017-01-01

    The aim of study was to establish a mouse model of blue light emitting diode (LED) light-induced retinal damage and to evaluate the effects of the antioxidant N-acetylcysteine (NAC). Mice were exposed to 400 or 800 lx blue LED light for 2 h, and were evaluated for retinal damage 5 d later by electroretinogram amplitude and outer nuclear layer (ONL) thickness. Additionally, we investigated the effect of blue LED light exposure on shorts-wave-sensitive opsin (S-opsin), and rhodopsin expression by immunohistochemistry. Blue LED light induced light intensity dependent retinal damage and led to collapse of S-opsin and altered rhodopsin localization from inner and outer segments to ONL. Conversely, NAC administered at 100 or 250 mg/kg intraperitoneally twice a day, before dark adaptation and before light exposure. NAC protected the blue LED light-induced retinal damage in a dose-dependent manner. Further, blue LED light-induced decreasing of S-opsin levels and altered rhodopsin localization, which were suppressed by NAC. We established a mouse model of blue LED light-induced retinal damage and these findings indicated that oxidative stress was partially involved in blue LED light-induced retinal damage.

  3. Physiological and genetic characterization of plant growth and gravitropism in LED light sources

    NASA Technical Reports Server (NTRS)

    Deitzer, Gerald F.

    1994-01-01

    Among the many problems of growing plants in completely controlled environments, such as those anticipated for the space station and the CELSS program, is the need to provide light that is both adequate for photosynthesis and of proper quality for normal growth and development. NASA scientists and engineers have recently become interested in the possibility of utilizing densely packed, solid state, light emitting diodes (LED's) as a source for this light. Unlike more conventional incandescent or electrical discharge lamps, these sources are highly monochromatic and lack energy in spectral regions thought to be important for normal plant development. In addition, a recent observation by NASA scientist has suggested that infra-red LED's, that are routinely used as photographic safelights for plants grown in darkness, may interact with the ability of plants to detect gravity. In order to establish how plants respond to light from these LED light sources we carried out a series of experiments with known pigment mutants of the model mustard plant, Arabidopsis thaliana, growing in either a gravity field or on a clinostat to simulate a micro-gravity environment. Results indicate that only red light from the 665 nm LED's disrupts the ability of normal wildtype seedlings to detect a gravity stimulus. There was no consistent effect found for the far-red (735 nm) LED's or either of the infrared (880 nm or 935 nm) LED sources but both showed some effect in one or more of the genotypes tested. Of these five members of the phytochrome multigene family in Arabidopsis, only the phytochrome B pigment mutant (hy3) lacked the ability to detect gravity under all conditions. There was no effect of either micro-gravity (clinostat) or the infra-red LED's on the light induced inhibition of hypocotyl elongation. Measurements of the pigment phytochrome in oats also showed no photoconversion by 15 min irradiations with the infra-red LED's. We conclude that phytochrome B is required for the

  4. Designing Instructor-Led Schools with Rapid Prototyping.

    ERIC Educational Resources Information Center

    Lange, Steven R.; And Others

    1996-01-01

    Rapid prototyping involves abandoning many of the linear steps of traditional prototyping; it is instead a series of design iterations representing each major stage. This article describes the development of an instructor-led course for midlevel auditors using the principles and procedures of rapid prototyping, focusing on the savings in time and…

  5. Pupil-led sex education in England (RIPPLE study): cluster-randomised intervention trial.

    PubMed

    Stephenson, J M; Strange, V; Forrest, S; Oakley, A; Copas, A; Allen, E; Babiker, A; Black, S; Ali, M; Monteiro, H; Johnson, A M

    Improvement of sex education in schools is a key part of the UK government's strategy to reduce teenage pregnancy in England. We examined the effectiveness of one form of peer-led sex education in a school-based randomised trial of over 8000 pupils. 29 schools were randomised to either peer-led sex education (intervention) or to continue their usual teacher-led sex education (control). In intervention schools, peer educators aged 16-17 years delivered three sessions of sex education to 13-14 year-old pupils from the same schools. Primary outcome was unprotected (without condom) first heterosexual intercourse by age 16 years. Analysis was by intention to treat. By age 16 years, significantly fewer girls reported intercourse in the peer-led arm than in the control arm, but proportions were similar for boys. The proportions of pupils reporting unprotected first sex did not differ for girls (8.4% intervention vs 8.3% control) or for boys (6.2% vs 4.7%). Stratified estimates of the difference between arms were -0.4% (95% CI -3.7% to 2.8%, p=0.79) for girls and -1.4% (-4.4% to 1.6%, p=0.36) for boys. At follow-up (mean age 16.0 years [SD 0.32]), girls in the intervention arm reported fewer unintended pregnancies, although the difference was borderline (2.3% vs 3.3%, p=0.07). Girls and boys were more satisfied with peer-led than teacher-led sex education, but 57% of girls and 32% of boys wanted sex education in single-sex groups. Peer-led sex education was effective in some ways, but broader strategies are needed to improve young people's sexual health. The role of single-sex sessions should be investigated further.

  6. Development of a new water sterilization device with a 365 nm UV-LED.

    PubMed

    Mori, Mirei; Hamamoto, Akiko; Takahashi, Akira; Nakano, Masayuki; Wakikawa, Noriko; Tachibana, Satoko; Ikehara, Toshitaka; Nakaya, Yutaka; Akutagawa, Masatake; Kinouchi, Yohsuke

    2007-12-01

    Ultraviolet (UV) irradiation is an effective disinfection method. In sterilization equipment, a low-pressure mercury lamp emitting an effective germicidal UVC (254 nm) is used as the light source. However, the lamp, which contains mercury, must be disposed of at the end of its lifetime or following damage due to physical shock or vibration. We investigated the suitability of an ultraviolet light-emitting diode at an output wavelength of 365 nm (UVA-LED) as a sterilization device, comparing with the other wavelength irradiation such as 254 nm (a low-pressure mercury lam) and 405 nm (LED). We used a commercially available UVA-LED that emitted light at the shortest wavelength and at the highest output energy. The new sterilization system using the UVA-LED was able to inactivate bacteria, such as Escherichia coli DH5 alpha, Enteropathogenic E. coli, Vibrio parahaemolyticus, Staphylococcus aureus, and Salmonella enterica serovar Enteritidis. The inactivations of the bacteria were dependent on the accumulation of UVA irradiation. Taking advantage of the safety and compact size of LED devices, we expect that the UVA-LED sterilization device can be developed as a new type of water sterilization device.

  7. Effect of multi-wavelength irradiation on color characterization with light-emitting diodes (LEDs)

    NASA Astrophysics Data System (ADS)

    Park, Hyeong Ju; Song, Woosub; Lee, Byeong-Il; Kim, Hyejin; Kang, Hyun Wook

    2017-06-01

    In the current study, a multi-wavelength light-emitting diode (LED)-integrated CMOS imaging device was developed to investigate the effect of various wavelengths on multiple color characterization. Various color pigments (black, red, green, and blue) were applied on both white paper and skin phantom surfaces for quantitative analysis. The artificial skin phantoms were made of polydimethylsiloxane (PDMS) mixed with coffee and TiO2 powder to emulate the optical properties of the human dermis. The customized LED-integrated imaging device acquired images of the applied pigments by sequentially irradiating with the LED lights in the order of white, red, green, and blue. Each color pigment induced a lower contrast during illumination by the light with the equivalent color. However, the illumination by light with the complementary (opposite) color increased the signal-to-noise ratio by up to 11-fold due to the formation of a strong contrast ( i.e., red LED = 1.6 ± 0.3 vs. green LED = 19.0 ± 0.6 for red pigment). Detection of color pigments in conjunction with multi-wavelength LEDs can be a simple and reliable technique to estimate variations in the color pigments quantitatively.

  8. Estimation of crosstalk in LED fNIRS by photon propagation Monte Carlo simulation

    NASA Astrophysics Data System (ADS)

    Iwano, Takayuki; Umeyama, Shinji

    2015-12-01

    fNIRS (functional near-Infrared spectroscopy) can measure brain activity non-invasively and has advantages such as low cost and portability. While the conventional fNIRS has used laser light, LED light fNIRS is recently becoming common in use. Using LED for fNIRS, equipment can be more inexpensive and more portable. LED light, however, has a wider illumination spectrum than laser light, which may change crosstalk between the calculated concentration change of oxygenated and deoxygenated hemoglobins. The crosstalk is caused by difference in light path length in the head tissues depending on wavelengths used. We conducted Monte Carlo simulations of photon propagation in the tissue layers of head (scalp, skull, CSF, gray matter, and white matter) to estimate the light path length in each layers. Based on the estimated path lengths, the crosstalk in fNIRS using LED light was calculated. Our results showed that LED light more increases the crosstalk than laser light does when certain combinations of wavelengths were adopted. Even in such cases, the crosstalk increased by using LED light can be effectively suppressed by replacing the value of extinction coefficients used in the hemoglobin calculation to their weighted average over illumination spectrum.

  9. Degradation modeling of mid-power white-light LEDs by using Wiener process.

    PubMed

    Huang, Jianlin; Golubović, Dušan S; Koh, Sau; Yang, Daoguo; Li, Xiupeng; Fan, Xuejun; Zhang, G Q

    2015-07-27

    The IES standard TM-21-11 provides a guideline for lifetime prediction of LED devices. As it uses average normalized lumen maintenance data and performs non-linear regression for lifetime modeling, it cannot capture dynamic and random variation of the degradation process of LED devices. In addition, this method cannot capture the failure distribution, although it is much more relevant in reliability analysis. Furthermore, the TM-21-11 only considers lumen maintenance for lifetime prediction. Color shift, as another important performance characteristic of LED devices, may also render significant degradation during service life, even though the lumen maintenance has not reached the critical threshold. In this study, a modified Wiener process has been employed for the modeling of the degradation of LED devices. By using this method, dynamic and random variations, as well as the non-linear degradation behavior of LED devices, can be easily accounted for. With a mild assumption, the parameter estimation accuracy has been improved by including more information into the likelihood function while neglecting the dependency between the random variables. As a consequence, the mean time to failure (MTTF) has been obtained and shows comparable result with IES TM-21-11 predictions, indicating the feasibility of the proposed method. Finally, the cumulative failure distribution was presented corresponding to different combinations of lumen maintenance and color shift. The results demonstrate that a joint failure distribution of LED devices could be modeled by simply considering their lumen maintenance and color shift as two independent variables.

  10. How Science Really Works: The Student Experience of Research-Led Education

    ERIC Educational Resources Information Center

    Smyth, Lillian; Davila, Federico; Sloan, Thomas; Rykers, Ellen; Backwell, Sam; Jones, Stephen B.

    2016-01-01

    There has been a shift in modern tertiary education theory that has moved away from a traditional, didactic model of education, towards a more student-led, constructivist approach. Nowhere is this more the case than in science and mathematical education, where the concept of research-led education is gaining more and more traction. The focus of…

  11. LEDs on the threshold for use in projection systems: challenges, limitations and applications

    NASA Astrophysics Data System (ADS)

    Moffat, Bryce Anton

    2006-02-01

    The use of coloured LEDs as light sources in digital projectors depends on an optimal combination of optical, electrical and thermal parameters to meet the performance and cost targets needed to enable these products to compete in the marketplace. This paper describes the system design methodology for a digital micromirror display (DMD) based optical engine using LEDs as the light source, starting at the basic physical and geometrical parameters of the DMD and other optical elements through characterization of the LEDs to optimizing the system performance by determining optimal driving conditions. The main challenge in using LEDs is the luminous flux density, which is just at the threshold of acceptance in projection systems and thus only a fully optimized optical system with a uniformly bright set of LEDs can be used. As a result of this work we have developed two applications: a compact pocket projector and a rear projection television.

  12. Design of LED fish lighting attractors using horizontal/vertical LIDC mapping method.

    PubMed

    Shen, S C; Huang, H J

    2012-11-19

    This study employs a sub-module concept to develop high-brightness light-emitting diode (HB-LED) fishing light arrays to replace traditional fishing light attractors. The horizontal/vertical (H/V) plane light intensity distribution curve (LIDC) of a LED light source are mapped to assist in the design of a non-axisymmetric lens with a fish-attracting light pattern that illuminates sufficiently large areas and alternates between bright and dark. These LED fishing light attractors are capable of attracting schools of fish toward the perimeter of the luminous zone surrounding fishing boats. Three CT2 boats (10 to 20 ton capacity) were recruited to conduct a field test for 1 y on the sea off the southwestern coast of Taiwan. Field tests show that HB-LED fishing light array installed 5 m above the boat deck illuminated a sea surface of 5 × 12 m and achieved an illuminance of 2000 lx. The test results show that the HB-LED fishing light arrays increased the mean catch of the three boats by 5% to 27%. In addition, the experimental boats consumed 15% to 17% less fuel than their counterparts.

  13. Polymerization of a dual-cured cement through ceramic: LED curing light vs halogen lamp.

    PubMed

    Lopes, Lawrence Gonzaga; Franco, Eduardo Batista; Name Neto, Abrão; Herrera, Francyle S; Kurachi, Cristina; Castañeda-Espinosa, Juan C; Lauris, José Roberto Pereira

    2004-12-01

    The aim of this study was to investigate the influence of light source, LED unit and halogen lamp (HL), on the effectiveness of Enforce dual-cured cement cured under a ceramic disc. Three exposure times (60, 80 and 120 s) were also evaluated. Two experimental groups, in which the polymerization of the dual-cured cement was performed through a ceramic disc, and two control groups, in which the polymerization of the dual-cured cement was performed directly without presence of ceramic disc were subdivided into three subgroups (three different exposure times), with five specimens each: G1A- HL 60s; G1B- HL 80s; G1C- HL 120s; G2A- LED 60s; G2B- LED 80s; G2C- LED 120s; and control groups: G3A- HL 60s; G3B- HL 80s; G3C- HL 120s; G4A- LED 60s; G4B- LED 80s and G4C- LED 120s. Cement was applied in a steel matrix (4mm diameter, 1.2mm thickness). In the experimental groups, a ceramic disc was placed on top. The cement was light-cured through the ceramic by a HL and LED, however, the control groups were cured without the ceramic disc. The specimens were stored in a light-proof container at 37ºC for 24 hours, then Vickers hardness was determined. A four-way ANOVA and Tukey test (p£ 0.05) were performed. All specimens cured by LED for 60s showed inferior values compared with the halogen groups. In general, light-curing by LED for 80s and 120s was comparable to halogen groups (60s and 80s) and their control groups. LED technology can be viable for light-curing through conventional ceramic indirect restorations, when curing time is increased in relation to HL curing time.

  14. Dimming LEDs with Phase-Cut Dimmers. The Specifier's Process for Maximizing Success

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, N. J.; Poplawski, M. E.

    2013-10-01

    DOE GATEWAY program report reviewing how phase-cut dimmers work, how LEDs differ from the incandescent lamps these dimmers were originally designed to control, and how those differences can lead to complications when attempting to dim LEDs. Providing both general guidance and step-by-step procedures for designing phase-controlled LED dimming on both new and existing projects—as well as real-world examples of how to use those procedures—the report aims to reduce the chance of experiencing compatibility-related problems and, if possible, ensure good dimming performance.

  15. Improved color coordinates of green monochromatic pc-LED capped with a band-pass filter.

    PubMed

    Oh, Ji Hye; Yang, Su Ji; Sung, Yeon-Goog; Do, Young Rag

    2013-02-25

    This study introduces a "greener" green monochromatic phosphor-converted light-emitting diode (pc-LED) using a band-pass filter (BPF) combined with a long-pass dichroic filter (LPDF) and a short-pass dichroic filter (SPDF) to improve the color quality of our previously developed LPDF-capped green pc-LED. This can also address the drawbacks of III-V semiconductor-type green LEDs, which show a low luminous efficacy and a poor current dependence of the efficacy and color coordinates compared to blue semiconductor-type LEDs. The optical properties of green monochromatic pc-LEDs using a BPF are compared with those of LPDF-capped green pc-LEDs, which have a broad band spectrum, and III-V semiconductor-type green LEDs by changing the transmittance wavelength range of the BPF and the peak wavelength of the green phosphors. BPF-capped green monochromatic pc-LEDs provide a high luminous efficacy (134 lm/W at 60 mA), and "greener" 1931 Commission Internationale d'Eclairage (CIE; CIEx, CIEy) color coordinates (0.24, 0.66) owing to the narrowed emission spectrum. We also propose a two-dimensional (2D) polystyrene (PS) microbead (2-μm diameter) monolayer as a scattering layer to overcome the poor angular dependence of the color coordinates of the transmitted light through a nano-multilayered dichroic filter such as an LPDF or BPF. The 2D PS scattering layer improves the angular dependence of the green color emitted from a BPF-capped green pc-LED with only 3% loss of luminous efficacy.

  16. Benefits of pharmacist-led flu vaccination services in community pharmacy.

    PubMed

    Kirkdale, C L; Nebout, G; Megerlin, F; Thornley, T

    2017-01-01

    Seasonal influenza is a major cause of excess winter deaths and increased hospital admissions. There is a high level of economic burden associated with the infection. Although vaccination targets have been set to tackle this international issue, many countries struggle to reach these coverage targets for their at-risk populations using traditional delivery methods. Traditional providers include family doctors and nurses; however, pharmacist-led influenza vaccination has become a more commonly utilised aid to support vaccination targets. Community pharmacies are convenient and widely accessible and evaluations consistently demonstrate that patients are satisfied with pharmacist-led vaccinations. Allowing community pharmacists to administer influenza vaccination as an alternative option for delivery helps to increase the coverage rate of vaccination. In addition, commissioning community pharmacists to provide this service has been shown to contribute to achieving targets for those at-risk. Pharmacist-led influenza vaccination services can create value for payors and reduce pressure on health systems. This review aims to demonstrate the success of pharmacy-led influenza vaccinations, and the impact it has had in driving up immunisation rates within other countries. Experiences of countries such as England, Portugal and the United States provide evidence to demonstrate the benefit to both the patient and the health system. Copyright © 2016 Académie Nationale de Pharmacie. Published by Elsevier Masson SAS. All rights reserved.

  17. Cooling of High-Power LED Lamp Using a Commercial Paraffin Wax

    NASA Astrophysics Data System (ADS)

    Zmywaczyk, J.; Zbińkowski, P.; Smogór, H.; Olejnik, A.; Koniorczyk, P.

    2017-03-01

    Commercial paraffin wax used by Bolsius Nederland B.V. for manufacturing various kinds of candles was applied as a phase-change material (PCM) for cooling a 28 W high-power light emitting diode (LED) panel during its operation. The main problem arising during operation of an LED is thermal management. According to the manufacturer's datasheet specifications (BioSolution Ltd. www.biosolution.pl, the operating temperature range for the LED street lamp UL28W is (-30 {°}C) to (+40 {°}C). The object of the present study was an LED panel containing 28 pieces of high-power 1W LEDs connected in series (4 LEDs in each of the 7 rows) mounted on an aluminum plate of dimensions 80 mm by 135 mm. The tested aluminum plate was placed in a block made of aluminum with a hollow compartment containing Bolsius paraffin wax of density 914 kg\\cdot m^{-3} at room temperature. Temperatures were recorded using K-type thermocouples at selected locations of the tested LED panel for several values of the power supplied to it, while utilizing PCM and without it. As the manufacturer of Bolsius wax candles does not provide any data on the thermal properties of the material used, it was necessary to carry out micro-calorimetric research. Thermophysical properties of the paraffin wax such as the apparent specific heat, enthalpy of phase transition and temperature of phase change transition during heating and cooling were determined using the Netzsch DSC 214 Polyma. The Netzsch TG 209F3 Tarsus was used for TG/DTG measurements. DSC investigations revealed the following thermal transitions taking place during the first heating: solid-solid transition (onset 30.4 {°}C, peak at 40.9 {°}C), solid-liquid transition (onset 47.7 {°}C, peak at 54.9 {°}C, end at 58.3 {°}C), latent heat of energy storage 201 J\\cdot g^{-1}, apparent specific heat corresponding to peak at 41.5 {°}C (5.498 J\\cdot g^{-1}\\cdot K^{-1}). DTG investigations revealed that the decomposition of paraffin wax is a two

  18. Newly patented process enables low-cost solution for increasing white light spectrum of LEDs

    NASA Astrophysics Data System (ADS)

    Spanard, Jan-Marie

    2017-10-01

    A newly patented process for completing the spectral light array emitted by LED bulbs provides a low-cost method for producing better human centered lighting (HCL). This process uses non-luminescent colorant filters, filling out the jagged LED spectral emission into a full, white light array. While LED bulbs have the distinct economic advantages of using less energy, producing less heat and lasting years longer than traditional incandescent bulbs, the persistent metameric failure of LED bulbs has resulted in slower, and sometimes reluctant, adoption of LED lighting by the residential, retail and architectural markets. Adding missing wavelengths to LED generated bulbs via colorant filters increases the aesthetic appeal of the light by decreasing current levels of metameric failure, reducing the `flatness', `harshness', and `dullness' of LED generated light reported by consumers. LED phosphor-converted light can be successfully tuned to "whiter" white light with selective color filtering using permanent, durable transparent pigments. These transparent pigments are selectively applied in combination with existing manufacturing technologies and utilized as a final color-tuning step in bulb design. The quantity of emitted light chosen for color filtering can be adjusted from 1% to 100% of emitted light, creating a custom balance of light quantity with light quality. This invention recognizes that "better light" is frequently chosen over "more light" in the consumer marketplace.

  19. Systematic synthesis of barriers and facilitators to service user-led care planning

    PubMed Central

    Bee, Penny; Price, Owen; Baker, John; Lovell, Karina

    2015-01-01

    Background Service user (patient) involvement in care planning is a principle enshrined by mental health policy yet often attracts criticism from patients and carers in practice. Aims To examine how user-involved care planning is operationalised within mental health services and to establish where, how and why challenges to service user involvement occur. Method Systematic evidence synthesis. Results Synthesis of data from 117 studies suggests that service user involvement fails because the patients' frame of reference diverges from that of providers. Service users and carers attributed highest value to the relational aspects of care planning. Health professionals inconsistently acknowledged the quality of the care planning process, tending instead to define service user involvement in terms of quantifiable service-led outcomes. Conclusions Service user-involved care planning is typically operationalised as a series of practice-based activities compliant with auditor standards. Meaningful involvement demands new patient-centred definitions of care planning quality. New organisational initiatives should validate time spent with service users and display more tangible and flexible commitments to meeting their needs. PMID:26243762

  20. Systematic synthesis of barriers and facilitators to service user-led care planning.

    PubMed

    Bee, Penny; Price, Owen; Baker, John; Lovell, Karina

    2015-08-01

    Service user (patient) involvement in care planning is a principle enshrined by mental health policy yet often attracts criticism from patients and carers in practice. To examine how user-involved care planning is operationalised within mental health services and to establish where, how and why challenges to service user involvement occur. Systematic evidence synthesis. Synthesis of data from 117 studies suggests that service user involvement fails because the patients' frame of reference diverges from that of providers. Service users and carers attributed highest value to the relational aspects of care planning. Health professionals inconsistently acknowledged the quality of the care planning process, tending instead to define service user involvement in terms of quantifiable service-led outcomes. Service user-involved care planning is typically operationalised as a series of practice-based activities compliant with auditor standards. Meaningful involvement demands new patient-centred definitions of care planning quality. New organisational initiatives should validate time spent with service users and display more tangible and flexible commitments to meeting their needs. © The Royal College of Psychiatrists 2015.