Sample records for technetium additions

  1. Solar neutrino production of technetium-97 and technetium-98.

    PubMed

    Cowan, G A; Haxton, W C

    1982-04-02

    It may be possible to determine the boron-8 solar neutrino flux, averaged over the past several million years, from the concentration of technetium-98 in molybdenite. The mass spectrometry of this system is greatly simplified by the absence of stable technetium isotopes, and the presence of the fission product technetium-99 provides a monitor of uiranium-induced backgrounds. This geochemical experiment could provide the first test of nonstandard solar models that suggest a relation between the chlorine-37 solar neutrino puzzle and the recent ice age.

  2. Microbial methods of reducing technetium

    DOEpatents

    Wildung, Raymond E [Richland, WA; Garland, Thomas R [Greybull, WY; Gorby, Yuri A [Richland, WA; Hess, Nancy J [Benton City, WA; Li, Shu-Mei W [Richland, WA; Plymale, Andrew E [Richland, WA

    2001-01-01

    The present invention is directed toward a method for microbial reduction of a technetium compound to form other compounds of value in medical imaging. The technetium compound is combined in a mixture with non-growing microbial cells which contain a technetium-reducing enzyme system, a stabilizing agent and an electron donor in a saline solution under anaerobic conditions. The mixture is substantially free of an inorganic technetium reducing agent and its reduction products. The resulting product is Tc of lower oxidation states, the form of which can be partially controlled by the stabilizing agent. It has been discovered that the microorganisms Shewanella alga, strain Bry and Shewanelia putrifacians, strain CN-32 contain the necessary enzyme systems for technetium reduction and can form both mono nuclear and polynuclear reduced Tc species depending on the stabilizing agent.

  3. A Study of Tungsten-Technetium Alloys

    NASA Technical Reports Server (NTRS)

    Maltz, J. W.

    1965-01-01

    Technetium is a sister element to rhenium and has many properties that are similar to rhenium. It is predicted that technetium will have about the same effects on tungsten as rhenium in regard to increase in workability, lowered ductile to brittle transition temperature, and improved ductility. The objectives of the current work are to recover technetium from fission product wastes at Hanford Atomic Products Operation and reduce to purified metal; prepare W-Tc alloys containing up to 50 atomic% Tc; fabricate the alloy ingots to sheet stock, assessing the effect of technetium on workability; and perform metallurgical and mechanical properties evaluation of the fabricated alloys. Previous reports have described the separation and purification of 800 g of technetium metal powder, melting of technetium and W-Tc alloys, and some initial observation of the alloy material.

  4. Separation of uranium from technetium in recovery of spent nuclear fuel

    DOEpatents

    Friedman, Horace A.

    1985-01-01

    A method for decontaminating uranium product from the Purex process comprises addition of hydrazine to the product uranyl nitrate stream from the Purex process, which contains hexavalent (UO.sub.2.sup.2+) uranium and heptavalent technetium (TcO.sub.4 -). Technetium in the product stream is reduced and then complexed by the addition of oxalic acid (H.sub.2 C.sub.2 O.sub.4), and the Tc-oxalate complex is readily separated from the uranium by solvent extraction with 30 vol. % tributyl phosphate in n-dodecane.

  5. Radionuclide Basics: Technetium-99

    EPA Pesticide Factsheets

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  6. Separation of uranium from technetium in recovery of spent nuclear fuel

    DOEpatents

    Friedman, H.A.

    1984-06-13

    A method for decontaminating uranium product from the Purex 5 process comprises addition of hydrazine to the product uranyl nitrate stream from the Purex process, which contains hexavalent (UO/sub 2//sup 2 +/) uranium and heptavalent technetium (TcO/sub 4/-). Technetium in the product stream is reduced and then complexed by the addition of oxalic acid (H/sub 2/C/sub 2/O/sub 4/), and the Tc-oxalate complex is readily separated from the 10 uranium by solvent extraction with 30 vol % tributyl phosphate in n-dodecane.

  7. Bioinorganic Activity of Technetium Radiopharmaceuticals.

    ERIC Educational Resources Information Center

    Pinkerton, Thomas C.; And Others

    1985-01-01

    Technetium radiopharmaceuticals are diagnostic imaging agents used in the field of nuclear medicine to visualize tissues, anatomical structures, and metabolic disorders. Bioavailability of technetium complexes, thyroid imaging, brain imaging, kidney imaging, imaging liver function, bone imaging, and heart imaging are the major areas discussed. (JN)

  8. Technetium recovery from high alkaline solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, Charles A.

    2016-07-12

    Disclosed are methods for recovering technetium from a highly alkaline solution. The highly alkaline solution can be a liquid waste solution from a nuclear waste processing system. Methods can include combining the solution with a reductant capable of reducing technetium at the high pH of the solution and adding to or forming in the solution an adsorbent capable of adsorbing the precipitated technetium at the high pH of the solution.

  9. Process for extracting technetium from alkaline solutions

    DOEpatents

    Moyer, Bruce A.; Sachleben, Richard A.; Bonnesen, Peter V.

    1995-01-01

    A process for extracting technetium values from an aqueous alkaline solution containing at least one alkali metal hydroxide and at least one alkali metal nitrate, the at least one alkali metal nitrate having a concentration of from about 0.1 to 6 molar. The solution is contacted with a solvent consisting of a crown ether in a diluent for a period of time sufficient to selectively extract the technetium values from the aqueous alkaline solution. The solvent containing the technetium values is separated from the aqueous alkaline solution and the technetium values are stripped from the solvent.

  10. Redox-dependent solubility of technetium in low activity waste glass

    NASA Astrophysics Data System (ADS)

    Soderquist, Chuck Z.; Schweiger, Michael J.; Kim, Dong-Sang; Lukens, Wayne W.; McCloy, John S.

    2014-06-01

    The solubility of technetium was measured in a Hanford low activity waste (LAW) glass simulant, to investigate the extent that technetium solubility controls the incorporation of technetium into LAW glass. A series of LAW glass samples, spiked with 500-6000 ppm of Tc as potassium pertechnetate, were melted at 1000 °C in sealed fused quartz ampoules. Technetium solubility was determined in the quenched bulk glass to be 2000-2800 ppm, with slightly reducing conditions due to choice of milling media resulting in reductant contamination and higher solubility. The chemical form of technetium obtained by X-ray absorption near edge spectroscopy is mainly isolated, octahedrally-coordinated Tc(IV), with a minority of Tc(VII) in some glasses and TcO2 in two glasses. The concentration and speciation of technetium depends on glass redox and amount of technetium added. Salts formed at the top of higher technetium loaded glasses during the melt. The results of this study show that technetium solubility should not be a factor in technetium retention during melting of Hanford LAW glass.

  11. Kit for providing a technetium medical radioimaging agent

    DOEpatents

    Wildung, Raymond E.; Garland, Thomas R.; Li, Shu-Mei W.

    2000-01-01

    The present invention is directed toward a kit for microbial reduction of a technetium compound to form other compounds of value in medical imaging. The technetium compound is combined in a mixture with non-growing microbial cells which contain a technetium-reducing enzyme system, a stabilizing agent and an electron donor in a saline solution under anaerobic conditions. The mixture is substantially free of an inorganic technetium reducing agent and its reduction products. The resulting product is Tc of lower oxidation states, the form of which can be partially controlled by the stabilizing agent. It has been discovered that the microorganisms Shewanella alga, strain Bry and Shewanella putrifacians, strain CN-32 contain the necessary enzyme systems for technetium reduction and can form both mono nuclear and polynuclear reduced Tc species depending on the stabilizing agent.

  12. Technetium-99m: basic nuclear physics and chemical properties.

    PubMed

    Castronovo, F P

    1975-05-01

    The nuclear physics and chemical properties of technetium-99m are reviewed. The review of basic nuclear physics includes: classification of nuclides, nuclear stability, production of radionuclides, artificial production of molybdenum-99, production of technetium 99m and -99Mo-99mTc generators. The discussion of the chemistry of technetium includes a profile of several -99mCc-labeled radiopharmaceuticals.

  13. Non-pertechnetate Technetium Sensor Research and Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryan, Samuel A.; Rapko, Brian M.; Branch, Shirmir D.

    Several significant uncertainties remain regarding the understanding and modeling of the fate and speciation of technicium-99 ( 99Tc) in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as one or more non pertechnetate species that have not been identified and to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetatemore » species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99Tc in Hanford tanks and waste forms. This report summarizes work performed in FY2016 that was sponsored by the Department of Energy’s Office of Environmental Management and demonstrates the protocol for using fluorescent Tc(I)-tricarbonyl complex as a means to detect the non-pertechnetate species within tank waste solutions. The protocol was optimized with respect to ligand concentration, solvent choice, reaction temperature and time. This work culminated in the quantitation of Tc(I)-tricarbonyl within a waste simulant, using a standard addition method for measurement. This report also summarizes the synthesis and high-yield preparation of the low-valence technetium species, [Tc(CO) 3(H 2O) 3] +, which will be used as the technetium standard material for the demonstration of the non-pertechnetate species in actual wastes.« less

  14. Cohesive Relations for Surface Atoms in the Iron-Technetium Binary System

    DOE PAGES

    Taylor, Christopher D.

    2011-01-01

    Iron-technetium alloys are of relevance to the development of waste forms for disposition of radioactive technetium-99 obtained from spent nuclear fuel. Corrosion of candidate waste forms is a function of the local cohesive energy () of surface atoms. A theoretical model for calculating is developed. Density functional theory was used to construct a modified embedded atom (MEAM) potential for iron-technetium. Materials properties determined for the iron-technetium system were in good agreement with the literature. To explore the relationship between local structure and corrosion, MEAM simulations were performed on representative iron-technetium alloys and intermetallics. Technetium-rich phases have lower , suggesting thatmore » these phases will be more noble than iron-rich ones. Quantitative estimates of based on numbers of nearest neighbors alone can lead to errors up to 0.5 eV. Consequently, atomistic corrosion simulations for alloy systems should utilize physics-based models that consider not only neighbor counts, but also local compositions and atomic arrangements.« less

  15. Process for the extraction of technetium from uranium

    DOEpatents

    Gong, Cynthia-May S.; Poineau, Frederic; Czerwinski, Kenneth R.

    2010-12-21

    A spent fuel reprocessing method contacts an aqueous solution containing Technetium(V) and uranyl with an acidic solution comprising hydroxylamine hydrochloride or acetohydroxamic acid to reduce Tc(V) to Tc(II, and then extracts the uranyl with an organic phase, leaving technetium(II) in aqueous solution.

  16. Precipitation process for the removal of technetium values from nuclear waste solutions

    DOEpatents

    Walker, D.D.; Ebra, M.A.

    1985-11-21

    High efficiency removal of techetium values from a nuclear waste stream is achieved by addition to the waste stream of a precipitant contributing tetraphenylphosphonium cation, such that a substantial portion of the technetium values are precipitated as an insoluble pertechnetate salt.

  17. A biokinetic model for systemic technetium in adult humans

    DOE PAGES

    Leggett, Richard Wayne; Giussani, Augusto

    2015-04-10

    The International Commission on Radiological Protection (ICRP) currently is updating its biokinetic and dosimetric models for internally deposited radionuclides. Technetium (Tc), the lightest element that exists only in radioactive form, has two important isotopes from the standpoint of potential risk to humans: the long-lived isotope 99Tm(T 1/2=2.1x10 5 y) is present in high concentration in nuclear waste, and the short-lived isotope 99mTc (T 1/2=6.02 h) is the most commonly used radionuclide in diagnostic nuclear medicine. This paper reviews data on the biological behavior of technetium and proposes a biokinetic model for systemic technetium in the adult human body formore » use in radiation protection. Compared with the ICRP s current occupational model for systemic technetium, the proposed model provides a more realistic description of the paths of movement of technetium in the body; provides greater consistency with experimental and medical data; and, for most radiosensitive organs, yields substantially different estimates of cumulative activity (total radioactive decays within the organ) following uptake of 99Tm or 99mTc to blood.« less

  18. Recovery of Technetium Adsorbed on Charcoal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelmann, Mark D.; Metz, Lori A.; Ballou, Nathan E.

    2006-05-01

    Two methods capable of near complete recovery of technetium adsorbed on charcoal are presented. The first involves liquid extraction of the technetium from the charcoal by hot 4M nitric acid. An average recovery of 98% (n=3) is obtained after three rounds of extraction. The second method involves dry ashing with air in a quartz combustion tube at 400-450 C. This method yields an average recovery of 96% (n=5). Other thermal methods were attempted, but resulted in reduced recovery and incomplete material balance

  19. Process for removing technetium from iron and other metals

    DOEpatents

    Leitnaker, J.M.; Trowbridge, L.D.

    1999-03-23

    A process for removing technetium from iron and other metals comprises the steps of converting the molten, alloyed technetium to a sulfide dissolved in manganese sulfide, and removing the sulfide from the molten metal as a slag. 4 figs.

  20. SEPARATION OF TECHNETIUM FROM AQUEOUS SOLUTIONS BY COPRECIPITATION WITH MAGNETITE

    DOEpatents

    Rimshaw, S.J.

    1961-10-24

    A method of separating technetium in the 4+ oxidation state from an aqueous basic solution containing products of uranium fission is described. The method consists of contacting the solution with finely divided magnetite and recovering a technetium-bearing precipitate. (AEC)

  1. Technetium: The First Radioelement on the Periodic Table

    DOE PAGES

    Johnstone, Erik V.; Yates, Mary Anne; Poineau, Frederic; ...

    2017-02-21

    The radioactive nature of technetium is discussed using a combination of introductory nuclear physics concepts and empirical trends observed in the chart of the nuclides and the periodic table of the elements. Trends such as the enhanced stability of nucleon pairs, magic numbers, and Mattauch's rule are described. Here, the concepts of nuclear binding energies and the nuclear shell model are introduced and used to explain the relative stability of radionuclides and, in particular, the isotopes of technetium.

  2. Equation of state for technetium from X-ray diffraction and first-principle calculations

    NASA Astrophysics Data System (ADS)

    Mast, Daniel S.; Kim, Eunja; Siska, Emily M.; Poineau, Frederic; Czerwinski, Kenneth R.; Lavina, Barbara; Forster, Paul M.

    2016-08-01

    The ambient temperature equation of state (EoS) of technetium metal has been measured by X-ray diffraction. The metal was compressed using a diamond anvil cell and using a 4:1 methanol-ethanol pressure transmitting medium. The maximum pressure achieved, as determined from the gold pressureEquation of state for technetium from X-ray diffraction and first-principle calculations scale, was 67 GPa. The compression data shows that the HCP phase of technetium is stable up to 67 GPa. The compression curve of technetium was also calculated using first-principles total-energy calculations. Utilizing a number of fitting strategies to compare the experimental and theoretical data it is determined that the Vinet equation of state with an ambient isothermal bulk modulus of B0T=288 GPa and a first pressure derivative of B‧=5.9(2) best represent the compression behavior of technetium metal.

  3. The Evaluation of Novel Tin Materials for the Removal of Technetium from Groundwater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Kent E.; Wellman, Dawn M.

    2017-06-30

    Technetium-99 ( 99Tc) is present at several U.S. Department of Energy (DOE) facilities, including the Hanford, Oak Ridge, Paducah, Portsmouth, and Savannah River sites. Due to its mobility, persistence, and toxicity in the environment, developing means to immobilize and/or remove technetium from the environment is currently a top priority for DOE. However, there are currently very few approaches that effectively manage the risks of technetium to human health and the environment. The objective of this study is to evaluate novel synthetic materials that could enable direct removal of technetium from groundwater. The following report •assesses the viability of existing methodologiesmore » for synthesis of tin (II) apatite for in situ formation and remediation of 99Tc within the subsurface environment •discusses the development of alternative methodologies for production of tin (II) apatite •evaluates nanoporous tin phosphate materials for removal of technetium from groundwater.« less

  4. Method for recovering palladium and technetium values from nuclear fuel reprocessing waste solutions

    DOEpatents

    Horwitz, E. Philip; Delphin, Walter H.

    1979-07-24

    A method for recovering palladium and technetium values from nuclear fuel reprocessing waste solutions containing these and other values by contacting the waste solution with an extractant of tricaprylmethylammonium nitrate in an inert hydrocarbon diluent which extracts the palladium and technetium values from the waste solution. The palladium and technetium values are recovered from the extractant and from any other coextracted values with a strong nitric acid strip solution.

  5. Speciation and Oxidative Stability of Alkaline Soluble, Non-Pertechnetate Technetium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levitskaia, Tatiana G.; Rapko, Brian M.; Anderson, Amity

    2014-09-30

    The long half-life, complex chemical behavior in tank waste, limited incorporation in mid- to high-temperature immobilization processes, and high mobility in subsurface environments make technetium (Tc) one of the most difficult contaminants to dispose of and/or remediate. Technetium exists predominantly in the liquid tank waste phase as the relatively mobile form of pertechnetate, TcO 4 -. However, based on experimentation to date a significant fraction of the soluble Tc cannot be effectively separated from the wastes and may be present as a non- pertechnetate species. The presence of a non-pertechnetate species significantly complicates disposition of low-activity waste (LAW), and themore » development of methods to either convert them to pertechnetate or to separate directly is needed. The challenge is the uncertainty regarding the chemical form of the alkaline-soluble low-valent non-pertechnetate species in the liquid tank waste. This report summarizes work done in fiscal year (FY) 2014 exploring the chemistry of a low-valence technetium(I) species, [(CO) 3Tc(H 2O) 3] +, a compound of interest due to its implication in the speciation of alkaline-soluble technetium in several Hanford tank waste supernatants.« less

  6. Deep liquid-chromatographic purification of uranium extract from technetium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volk, V.; Dvoeglazov, K; Podrezova, L.

    The recycling of uranium in the nuclear fuel cycle requires the removal of a number of radioactive and stable impurities like {sup 99}Tc from spent fuels. In order to improve the grade of uranium extract purification from technetium the method of liquid chromatography and the apparatus for its performance have been developed. Process of technetium extraction and concentrating in aqueous solution containing reducing agent has been studied on simulated solutions (U-Tc-HNO{sub 3}-30% TBP-isoparM). The dynamic tests of the method have been carried out on the laboratory unit. Solution of diformyl-hydrazine in nitric acid was used as a stationary phase. Silicamore » gel with specific surface of 186 m{sup 2}/g was used as a carrier of the stationary phase. It is shown that the volume of purified extract increases as the solution temperature increases, concentration of reducing agent increases and extract flow rate decreases. It is established that the technetium content in uranium by this method could achieve a value below 0.3 ppm. Some variants of overload and composition of the stationary phase containing the extracted technetium have been offered and tested. It is defined that the method provides reduction of processing medium-active wastes by more than 10 times during finish refining process. (authors)« less

  7. Thermodynamics of technetium: Reconciling theory and experiment using density functional perturbation analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weck, Philippe F.; Kim, Eunja

    The structure, lattice dynamics and thermodynamic properties of bulk technetium were investigated within the framework of density functional theory. The phonon density of states spectrum computed with density functional perturbation theory closely matches inelastic coherent neutron scattering measurements. The thermal properties of technetium were derived from phonon frequencies calculated within the quasi-harmonic approximation (QHA), which introduces a volume dependence of phonon frequencies as a part of the anharmonic effect. As a result, the predicted thermal expansion and isobaric heat capacity of technetium are in excellent agreement with available experimental data for temperatures up to ~1600 K.

  8. Thermodynamics of technetium: Reconciling theory and experiment using density functional perturbation analysis

    DOE PAGES

    Weck, Philippe F.; Kim, Eunja

    2015-06-11

    The structure, lattice dynamics and thermodynamic properties of bulk technetium were investigated within the framework of density functional theory. The phonon density of states spectrum computed with density functional perturbation theory closely matches inelastic coherent neutron scattering measurements. The thermal properties of technetium were derived from phonon frequencies calculated within the quasi-harmonic approximation (QHA), which introduces a volume dependence of phonon frequencies as a part of the anharmonic effect. As a result, the predicted thermal expansion and isobaric heat capacity of technetium are in excellent agreement with available experimental data for temperatures up to ~1600 K.

  9. Diffusion of 99-technetium in compacted bentonite under aerobic and anaerobic conditions

    NASA Astrophysics Data System (ADS)

    Večerník, P.; Jedináková-Křížová, V.

    2006-01-01

    The main aim of this study was to investigate diffusion of technetium 99Tc under different conditions. Because technetium represents one of the most dangerous fission products due to its very long halftime and high mobility in aerobic conditions diffusion experiments of technetium (as 99TcO 4 - anion) in Czech bentonite from Rokle locality have been carried out. For performance and evaluation of experiments the through-diffusion method was chosen and apparent (Da) and effective (De) diffusion coefficients were evaluated. The effects of particle mesh-size, dry bulk density and aerobic or anaerobic conditions on diffusion were studied. In the presence of oxygen, technetium occurs in oxidation state VII, as an anion, soluble and mobile in the environment. However, under reducing conditions it occurs in a lower oxidation states, mainly as insoluble oxides or hydroxides. Aerobic experiments were carried out under laboratory conditions and anaerobic experiments were performed in a nitrogen atmosphere in a glove box, to simulate the real underground conditions.

  10. Candidate Low-Temperature Glass Waste Forms for Technetium-99 Recovered from Hanford Effluent Management Facility Evaporator Concentrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Mei; Tang, Ming; Rim, Jung Ho

    Alternative treatment and disposition options may exist for technetium-99 (99Tc) in secondary liquid waste from the Hanford Direct-Feed Low-Activity Waste (DFLAW) process. One approach includes development of an alternate glass waste form that is suitable for on-site disposition of technetium, including salts and other species recovered by ion exchange or precipitation from the EMF evaporator concentrate. By recovering the Tc content from the stream, and not recycling the treated concentrate, the DFLAW process can potentially be operated in a more efficient manner that lowers the cost to the Department of Energy. This report provides a survey of candidate glass formulationsmore » and glass-making processes that can potentially incorporate technetium at temperatures <700 °C to avoid volatilization. Three candidate technetium feed streams are considered: (1) dilute sodium pertechnetate loaded on a non-elutable ion exchange resin; (2) dilute sodium-bearing aqueous eluent from ion exchange recovery of pertechnetate, or (3) technetium(IV) oxide precipitate containing Sn and Cr solids in an aqueous slurry. From the technical literature, promising candidate glasses are identified based on their processing temperatures and chemical durability data. The suitability and technical risk of three low-temperature glass processing routes (vitrification, encapsulation by sintering into a glass composite material, and sol-gel chemical condensation) for the three waste streams was assessed, based on available low-temperature glass data. For a subset of candidate glasses, their long-term thermodynamic behavior with exposure to water and oxygen was modeled using Geochemist’s Workbench, with and without addition of reducing stannous ion. For further evaluation and development, encapsulation of precipitated TcO2/Sn/Cr in a glass composite material based on lead-free sealing glasses is recommended as a high priority. Vitrification of pertechnetate in aqueous anion exchange eluent

  11. Equation of state for technetium from X-ray diffraction and first-principle calculations

    DOE PAGES

    Mast, Daniel S.; Kim, Eunja; Siska, Emily M.; ...

    2016-03-20

    Here, the ambient temperature equation of state (EoS) of technetium metal has been measured by X-ray diffraction. The metal was compressed using a diamond anvil cell and using a 4:1 methanol-ethanol pressure transmitting medium. The maximum pressure achieved, as determined from the gold pressure scale, was 67 GPa. The compression data shows that the HCP phase of technetium is stable up to 67 GPa. The compression curve of technetium was also calculated using first-principles total-energy calculations. Utilizing a number of fitting strategies to compare the experimental and theoretical data it is determined that the Vinet equation of state with anmore » ambient isothermal bulk modulus of B 0T = 288 GPa and a first pressure derivative of B' = 5.9(2) best represent the compression behavior of technetium metal.« less

  12. Technetium Tetrachloride Revisited: A Precursor to Lower-Valent Binary Technetium Chlorides

    DOE PAGES

    Johnstone, Erik V.; Poineau, Frederic; Forster, Paul M.; ...

    2012-07-09

    Technetium (Tc) is the lightest element that doesn't occur in nature. At UNLV, our radiochemistry program gives us access to Tc and the ability to make various Tc compounds. Here we describe the preparation and characterization of TcCl 4. The Tc atom is found to have a magnetic moment and magnetically orders at low temperature. As discerning trends in the transition metals, of which Tc is one, is important for understanding all transition metal compounds, this research is relevant to understanding these materials.

  13. 99M-Technetium labeled tin colloid radiopharmaceuticals

    DOEpatents

    Winchell, Harry S.; Barak, Morton; Van Fleet, III, Parmer

    1976-07-06

    An improved 99m-technetium labeled tin(II) colloid, size-stabilized for reticuloendothelial organ imaging without the use of macromolecular stabilizers and a packaged tin base reagent and an improved method for making it are disclosed.

  14. Separation of uranium from technetium in recovery of spent nuclear fuel

    NASA Astrophysics Data System (ADS)

    Friedman, H. A.

    1984-06-01

    A method for decontaminating uranium product from the Purex 5 process is described. Hydrazine is added to the product uranyl nitrate stream from the Purex process, which contains hexavalent (UO2(2+)) uranium and heptavalent technetius (TcO4-). Technetium in the product stream is reduced and then complexed by the addition of oxalic acid (H2O2O4), and the Tc-oxalate complex is readily separated from the 10 uranium by solvent extraction with 30 vol % tributyl phosphate in n-dodecane.

  15. APPLICATION OF FORMOHYDROXAMIC ACID IN NUCLEAR PROCESSING: SYNTHESIS AND COMPLEXATION WITH TECHNETIUM-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amber Wright; Edward Mausolf; Keri Campbell

    2010-05-01

    Acetohydroxamic acid (AHA) is an organic ligand planned for use in the Uranium Extraction (UREX) process. It reduces neptunium and plutonium, and the resultant hydrophilic complexes are separated from uranium by extraction with tributyl phosphate (TBP) in a hydrocarbon diluent. AHA undergoes hydrolysis to acetic acid which will impede the recycling of nitric acid. During recent discussions of the UREX process, it has been proposed to replace AHA by formohydroxamic acid (FHA). FHA will undergo hydrolysis to formic acid which is volatile, thus allowing the recycling of nitric acid. The reported reduction potentials of AHA and pertechnetate (TcO{sub 4}{sup -})more » indicated that it may be possible for AHA to reduce technetium, altering its fate in the fuel cycle. At UNLV, it has been demonstrated that TcO{sub 4}{sup -} undergoes reductive nitrosylation by AHA under a variety of conditions. The resulting divalent technetium is complexed by AHA to form the pseudo-octahedral trans-aquonitrosyl (diacetohydroxamic)-technetium(II) complex ([Tc{sup II}(NO)(AHA){sub 2}H{sub 2}O]{sup +}). In this paper, we are reporting the synthesis of FHA and its complex formation with technetium along with the characterization of FHA crystals achieved by NMR and IR spectroscopy. Two experiments were conducted to investigate the complexation of FHA with Tc and the results were compared with previous data on AHA. The first experiment involved the elution of Tc from a Reillex HP anion exchange resin, and the second one monitored the complexation of technetium with FHA by UV-visible spectrophotometry.« less

  16. Investigation of radioactivity concentration in spent technetium generators

    NASA Astrophysics Data System (ADS)

    Idriss, Hajo; Salih, Isam; Alaamer, Abdulaziz S.; Eisa, M. H.; Sam, A. K.

    2014-04-01

    This study was carried out to survey and measure radioactivity concentration and estimate radiation dose level at the surface of spent technetium generator columns for the safe final disposal of radioactive waste. High resolution γ-spectrometry with the aid of handheld radiation survey meters has been used. The radioactivity measurements has shown that 238U, 40K and 137Cs were only measurable in one sample whereas 125Sb was found in 14 samples out of total of 20 samples with an activity concentration which ranged from 21 to 7404 with an average value of 1095 Bq/kg. The activity concentration of 125Sb is highly variable indicating that the spent 99mTc generator columns are of different origin. This investigation highlighted the importance of radiation monitoring of spent technetium generators in the country in order to protect workers, and the public from the dangers posed by radioactive waste.

  17. Lung ventilation studies with technetium-99m Pseudogas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burch, W.M.; Sullivan, P.J.; Lomas, F.E.

    1986-06-01

    Technetium-99m Pseudogas is an ultrafine near monodisperse aerosol of 0.12-microgram diam particle size. This report describes initial clinical experiences with 27 patients referred for investigation of suspected pulmonary embolism, and in whom Pseudogas ventilation images were compared with a high quality commercial aerosol. An additional group of ten patients with severe COPD was examined in a comparative trial of Pseudogas with 81mKr. Pseudogas was better than a conventional aerosol in reaching a diagnosis of pulmonary embolism using a simple blinded comparison with coded images. In addition, bronchial deposition was minimal unless COPD was severe. Moderately well patients had no difficultymore » inhaling the necessary activity in one or two breaths, and even severely ill and frail aged persons could accomplish the passive breathing maneuver in less than a minute. Clearance of Pseudogas was directly to the systemic circulation with a half-time of 10 min in normal subjects extending up to 100 min in patients with airways disease.« less

  18. Increased technetium uptake is not equivalent to muscle necrosis: scintigraphic, morphological and intramuscular pressure analyses of sore muscles after exercise

    NASA Technical Reports Server (NTRS)

    Crenshaw, A. G.; Friden, J.; Hargens, A. R.; Lang, G. H.; Thornell, L. E.

    1993-01-01

    A scintigraphic technique employing technetium pyrophosphate uptake was used to identify the area of skeletal muscle damage in the lower leg of four runners 24 h after an ultramarathon footrace (160 km). Most of the race had been run downhill which incorporated an extensive amount of eccentric work. Soreness was diffuse throughout the posterior region of the lower leg. In order to interpret what increased technetium uptake reflects and to express extreme endurance related damages, a biopsy was taken from the 3-D position of abnormal uptake. In addition, intramuscular pressures were determined in the deep posterior compartment. Scintigraphs revealed increased technetium pyrophosphate uptake in the medial portion of the gastrocnemius muscle. For 3698 fibres analysed, 33 fibres (1%) were necrotic, while a few other fibres were either atrophic or irregular shaped. A cluster of necrotic fibres occurred at the fascicular periphery for one subject and fibre type grouping occurred for another. Ultrastructural analysis revealed Z-line streaming near many capillaries and variously altered subsarcolemmal mitochondria including some with paracrystalline inclusions. The majority of the capillaries included thickened and irregular shaped endothelial cells. Intramuscular pressures of the deep posterior compartment were slightly elevated (12-15 mmHg) for three of the four subjects. Increased technetium uptake following extreme endurance running does not just reflect muscle necrosis but also subtle fibre abnormalities. Collectively, these pathological findings are attributed to relative ischaemia occurring during the race and during pre-race training, whereas, intramuscular pressure elevations associated with muscle soreness are attributed to mechanical stress caused by extensive eccentric work during the race.

  19. Solubility Control of Technetium Release from Saltstone by Tc02•xH20

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cantrell, Kirk J.; Williams, Benjamin D.

    2013-11-12

    Saltstone leaching experiments were conducted using a modified single-pass flow-through method under anoxic conditions. The analytical results of leachates collected from these experiments were evaluated using thermodynamic modeling to determine if the data were consistent with potential solubility controlling phases. The results demonstrate that technetium concentrations in water in contact with Saltstone under anoxic conditions is controlled by the solubility of TcO2•xH2O (likely TcO2•1.6H2O). In our system equilibrium solubility appears to have been reached within two weeks at a concentration of approximately 1.5 x 10-6 M. This concentration is likely to vary as the composition of Saltstone pore fluid evolvesmore » over time. As the pH goes from the initial high values (~12.5-13) to lower values, the solubility of technetium will decrease significantly. The thermodynamic data used to determine the solubility of TcO2•1.6H2O were taken from the tabulation of critically selected thermodynamic data determined by the Nuclear Energy Agency. Solid phase characterization to demonstrate the presence of TcO2•xH2O was not possible due to the low concentrations of technetium in our samples. Previous solid phase characterization studies with cementitious waste forms that were very similar to our Saltstone samples as well as reaction products derived from reductive immobilization of TcO4- by amorphous FeS clearly indicate the presence of TcO2 with varying degrees of hydration. Although, the presence of TcSx or other reduced technetium sulfide phases in our samples cannot be ruled out, release of technetium from Saltstone will be controlled by TcO2•1.6H2O because of its higher solubility. Our results clearly demonstrate that the release mechanism of technetium from Saltstone under reducing conditions is solubility controlled by TcO2•xH2O (likely TcO2•1.6H2O); however, distribution coefficients (Kds), that describe sorption and not solubility, were calculated

  20. Development of Alternative Technetium Waste Forms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Czerwinski, Kenneth

    2013-09-13

    The UREX+1 process is under consideration for the separation of transuranic elements from spent nuclear fuel. The first steps of this process extract the fission product technicium-99 ({sup 99}Tc) into an organic phase containing tributylphosphate together with uranium. Treatment of this stream requires the separation of Tc from U and placement into a suitable waste storage form. A potential candidate waste form involves immobilizing the Tc as an alloy with either excess metallic zirconium or stainless steel. Although Tc-Zr alloys seem to be promising waste forms, alternative materials must be investigated. Innovative studies related to the synthesis and behavior ofmore » a different class of Tc materials will increase the scientific knowledge related to development of Tc waste forms. These studies will also provide a better understanding of the behavior of {sup 99}Tc in repository conditions. A literature survey has selected promising alternative waste forms for further study: technetium metallic alloys, nitrides, oxides, sulfides, and pertechnetate salts. The goals of this project are to 1) synthesize and structurally characterize relevant technetium materials that may be considered as waste forms, 2) investigate material behavior in solution under different conditions of temperature, electrochemical potential, and radiation, and 3) predict the long-term behavior of these materials.« less

  1. Technetium: The First Radioelement on the Periodic Table

    ERIC Educational Resources Information Center

    Johnstone, Erik V.; Yates, Mary Anne; Poineau, Frederic; Sattelberger, Alfred P.; Czerwinski, Kenneth R.

    2017-01-01

    The radioactive nature of technetium is discussed using a combination of introductory nuclear physics concepts and empirical trends observed in the chart of the nuclides and the periodic table of the elements. Trends such as the enhanced stability of nucleon pairs, magic numbers, and Mattauch's rule are described. The concepts of nuclear binding…

  2. Characterization of Technetium Speciation in Cast Stone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Jung, Hun Bok; Wang, Guohui

    2013-11-11

    This report describes the results from laboratory tests performed at Pacific Northwest National Laboratory (PNNL) for the U.S. Department of Energy (DOE) EM-31 Support Program (EMSP) subtask, “Production and Long-Term Performance of Low Temperature Waste Forms” to provide additional information on technetium (Tc) speciation characterization in the Cast Stone waste form. To support the use of Cast Stone as an alternative to vitrification for solidifying low-activity waste (LAW) and as the current baseline waste form for secondary waste streams at the Hanford Site, additional understanding of Tc speciation in Cast Stone is needed to predict the long-term Tc leachability frommore » Cast Stone and to meet the regulatory disposal-facility performance requirements for the Integrated Disposal Facility (IDF). Characterizations of the Tc speciation within the Cast Stone after leaching under various conditions provide insights into how the Tc is retained and released. The data generated by the laboratory tests described in this report provide both empirical and more scientific information to increase our understanding of Tc speciation in Cast Stone and its release mechanism under relevant leaching processes for the purpose of filling data gaps and to support the long-term risk and performance assessments of Cast Stone in the IDF at the Hanford Site.« less

  3. Immobilization and Limited Reoxidation of Technetium-99 by Fe(II)-Goethite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Chang, Hyun-shik; Icenhower, Jonathan P.

    2010-09-30

    This report summarizes the methodology used to test the sequestration of technetium-99 present in both deionized water and simulated Hanford Tank Waste Treatment and Immobilization Plant waste solutions.

  4. Assessment of the Cast Stone Low-Temperature Waste Form Technology Coupled with Technetium Removal - 14379

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Brown, Christopher F.; Rapko, Brian M.; Serne, R. Jeffrey

    2014-03-03

    The U.S. Department of Energy Office of Environmental Management (EM) is engaging the national laboratories to provide the scientific and technological rigor to support EM program and project planning, technology development and deployment, project execution, and assessment of program outcomes. As an early demonstration of this new responsibility, Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) were chartered to implement a science and technology program addressing low-temperature waste forms for immobilization of DOE aqueous waste streams, including technetium removal as an implementing technology. As a first step, the laboratories examined the technical risks and uncertainties associated withmore » the Cast Stone waste immobilization and technetium removal projects at Hanford. Science and technology gaps were identified for work associated with 1) conducting performance assessments and risk assessments of waste form and disposal system performance, and 2) technetium chemistry in tank wastes and separation of technetium from waste processing streams. Technical approaches to address the science and technology gaps were identified and an initial sequencing priority was suggested. A subset of research was initiated in 2013 to begin addressing the most significant science and technology gaps. The purpose of this paper is to report progress made towards closing these gaps and provide notable highlights of results achieved to date.« less

  5. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated withmore » other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate.« less

  6. Technetium and rhenium pentacarbonyl complexes with C₂ and C₁₁ ω-isocyanocarboxylic acid esters.

    PubMed

    Miroslavov, Alexander E; Polotskii, Yuriy S; Gurzhiy, Vladislav V; Ivanov, Alexander Yu; Lumpov, Alexander A; Tyupina, Margarita Yu; Sidorenko, Georgy V; Tolstoy, Peter M; Maltsev, Daniil A; Suglobov, Dmitry N

    2014-08-04

    Technetium(I) and rhenium(I) pentacarbonyl complexes with ethyl 2-isocyanoacetate and methyl 11-isocyanoundecanoate, [M(CO)5(CNCH2COOEt)]ClO4 (M = Tc (1) and Re (2)) and [M(CO)5(CN(CH2)10COOMe)]ClO4 (M = Tc (3) and Re (4)), were prepared and characterized by IR, (1)H NMR, and (13)C{(1)H} NMR spectroscopy. The crystal structures of 1 and 2 were determined using single-crystal X-ray diffraction. The kinetics of thermal decarbonylation of technetium complexes 1 and 3 in ethylene glycol was studied by IR spectroscopy. The rate constants and activation parameters of this reaction were determined and compared with those for [Tc(CO)6](+). It was found that rhenium complexes 2 and 4 were stable with respect to thermal decarbonylation. Histidine challenge reaction of complexes 1 and 2 in phosphate buffer was examined by IR spectroscopy. In the presence of histidine, the rhenium pentacarbonyl isocyanide complex partially decomposes to form an unidentified yellow precipitate. Technetium analogue 1 is more stable under these conditions.

  7. Evaluation of Technetium Getters to Improve the Performance of Cast Stone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neeway, James J.; Qafoku, Nikolla P.; Serne, R. Jeffrey

    2015-11-01

    Cast Stone has been selected as the preferred waste form for solidification of aqueous secondary liquid effluents from the Hanford Tank Waste Treatment and Immobilization Plant (WTP) process condensates and low-activity waste (LAW) melter off-gas caustic scrubber effluents. Cast Stone is also being evaluated as a supplemental immobilization technology to provide the necessary LAW treatment capacity to complete the Hanford tank waste cleanup mission in a timely and cost effective manner. One of the major radionuclides that Cast Stone has the potential to immobilize is technetium (Tc). The mechanism for immobilization is through the reduction of the highly mobile Tc(VII)more » species to the less mobile Tc(IV) species by the blast furnace slag (BFS) used in the Cast Stone formulation. Technetium immobilization through this method would be beneficial because Tc is one of the most difficult contaminants to address at the U.S. Department of Energy (DOE) Hanford Site due to its complex chemical behavior in tank waste, limited incorporation in mid- to high-temperature immobilization processes (vitrification, steam reformation, etc.), and high mobility in subsurface environments. In fact, the Tank Closure and Waste Management Environmental Impact Statement for the Hanford Site, Richland, Washington (TC&WM EIS) identifies technetium-99 ( 99Tc) as one of the radioactive tank waste components contributing the most to the environmental impact associated with the cleanup of the Hanford Site. The TC&WM EIS, along with an earlier supplemental waste-form risk assessment, used a diffusion-limited release model to estimate the release of different contaminants from the WTP process waste forms. In both of these predictive modeling exercises, where effective diffusivities based on grout performance data available at the time, groundwater at the 100-m down-gradient well exceeded the allowable maximum permissible concentrations for 99Tc. (900 pCi/L). Recent relatively short-term (63

  8. Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model.

    PubMed

    Tang, Cheng; Wang, Feng; Hou, Yanjie; Lu, Shanshan; Tian, Wei; Xu, Yan; Jin, Chengzhe; Wang, Liming

    2015-05-01

    Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.

  9. Reactions of technetium hexafluoride with nitric acid, nitrosyl fluoride, and nitryl fluoride

    NASA Technical Reports Server (NTRS)

    Holloway, J. H.; Selig, H.

    1970-01-01

    Stoichiometry of technetium hexafluoride reactions is studied. Magnetic properties and infrared spectra of reaction products are studied and compared with those of analogous complexes of the hexafluorides of tungsten, rhenium, and osmium.

  10. Accelerator Generation and Thermal Separation (AGATS) of Technetium-99m

    ScienceCinema

    Grover, Blaine

    2018-05-01

    Accelerator Generation and Thermal Separation (AGATS) of Technetium-99m is a linear electron accelerator-based technology for producing medical imaging radioisotopes from a separation process that heats, vaporizes and condenses the desired radioisotope. You can learn more about INL's education programs at http://www.facebook.com/idahonationallaboratory.

  11. Transglutaminase-mediated conjugation and nitride-technetium-99m labelling of a bis(thiosemicarbazone) bifunctional chelator.

    PubMed

    Salvarese, Nicola; Spolaore, Barbara; Marangoni, Selena; Pasin, Anna; Galenda, Alessandro; Tamburini, Sergio; Cicoria, Gianfranco; Refosco, Fiorenzo; Bolzati, Cristina

    2018-06-01

    An assessment study involving the use of the transglutaminase (TGase) conjugation method and the nitride-technetium-99m labelling on a bis(thiosemicarbazone) (BTS) bifunctional chelating agent is presented. The previously described chelator diacetyl-2-(N 4 -methyl-3-thiosemicarbazone)-3-(N 4 -amino-3-thiosemicarbazone), H 2 ATSM/A, has been functionalized with 6-aminohexanoic acid (ε-Ahx) to generate the bifunctional chelating agent diacetyl-2-(N 4 -methyl-3-thiosemicarbazone)-3-[N 4 -(amino)-(6-aminohexanoic acid)-3-thiosemicarbazone], H 2 ATSM/A-ε-Ahx (1), suitable for conjugation to glutamine (Gln) residues of bioactive molecules via TGase. The feasibility of the TGase reaction in the synthesis of a bioconjugate derivative was investigated using Substance P (SP) as model peptide. Compounds 1 and H 2 ATSM/A-ε-Ahx-SP (2) were labelled with nitride-technetium-99m, obtaining the complexes [ 99m Tc][Tc(N)(ATSM/A-ε-Ahx)] ( 99m Tc1) and [ 99m Tc][Tc(N)(ATSM/A-ε-Ahx-SP)] ( 99m Tc2). The chemical identity of 99m Tc1 and 99m Tc2 was confirmed by radio/UV-RP-HPLC combined with ESI-MS analysis on the respective carrier-added products 99g/99m Tc1 and 99g/99m Tc2. The stability of the radiolabelled complexes after incubation in various environments was investigated. All the results were compared with those obtained for the corresponding 64 Cu-analogues, 64 Cu1 and 64 Cu2. The TGase reaction allows the conjugation of 1 with the peptide, but it is not highly efficient due to instability of the chelator in the required conditions. The SP-conjugated complexes are unstable in mouse and human sera. However, indeed the BTS system can be exploited as nitride-technetium-99m chelator for highly efficient technetium labelling, thus making compound 1 worthy of further investigations for new targeted technetium and copper radiopharmaceuticals encompassing Single Photon Emission Computed Tomography and Positron Emission Tomography imaging. Copyright © 2018 Elsevier Inc. All rights

  12. Failure of technetium bone scanning to detect pseudarthroses in spinal fusion for scoliosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hannon, K.M.; Wetta, W.J.

    1977-01-01

    A prospective study of 11 patients suggests that present techniques of technetium bone scanning do not assist in recognizing the presence of well-established pseudarthrosis in spinal fusions for scoliosis.

  13. Hyperthermia increases accumulation of technetium-99m-labeled liposomes in feline sarcomas.

    PubMed

    Matteucci, M L; Anyarambhatla, G; Rosner, G; Azuma, C; Fisher, P E; Dewhirst, M W; Needham, D; Thrall, D E

    2000-09-01

    The effect of hyperthermia on the accumulation of technetium-99m-labeled liposomes was studied in feline sarcomas. Each cat received two separate injections of liposomes. The first was used to quantify the amount of technetium-99m-labeled liposomes within the tumor under normothermic conditions. The second injection was made at the beginning of a 60-min hyperthermia procedure. Planar scintigraphy was used to measure the activity of technetium-99m-labeled liposomes within the tumor at predetermined times up to 18 h after injection. Regions of interest were drawn for the tumor, lungs, liver, kidney, and aorta. Counts in the regions of interest were decay corrected. Counts/pixel in the tumor under normothermic and hyperthermic conditions were normalized to aorta counts/pixel. A total of 16 cats were eligible for the study. In two of the 16 cats, incomplete count data precluded analysis. In the remaining 14 cats, hyperthermia resulted in a significant increase in liposome accumulation in the tumor (P = 0.001). Tumor volume ranged from 1.2 to 236.2 cm3, and thermal dose ranged from 2.0 to 243.3 CEM43CT90 (equivalent time that the 10th percentile temperature was equal to 43 degrees C). There was not a relationship between either tumor volume or hyperthermia dose on the magnitude of increased liposome accumulation, suggesting that this method has application across a range of tumor volumes and degrees of heatibility.

  14. PREDICTION OF RELAPSE FROM HYPERTHYROIDISM FOLLOWING ANTITHYROID MEDICATION WITHDRAWAL USING TECHNETIUM THYROID UPTAKE SCANNING.

    PubMed

    Nakhjavani, Manouchehr; Abdollahi, Soraya; Farzanefar, Saeed; Abousaidi, Mohammadtagi; Esteghamati, Alireza; Naseri, Maryam; Eftekhari, Mohamad; Abbasi, Mehrshad

    2017-04-02

    Technetium thyroid uptake (TTU) is not inhibited by antithyroid drugs (ATD) and reflects the degree of thyroid stimulation. We intended to predict the relapse rate from hyperthyroidism based on TTU measurement. Out of 44 initially enrolled subjects, 38 patients aged 41.6 ± 14.6 with Graves disease (duration: 84 ± 78 months) completed the study. TTU was performed with 40-second imaging of the neck and mediastinum 20 minutes after injection of 1 mCi technetium-99m pertechnetate. TTU was measured as the percentage of the count of activity accumulated in the thyroidal region minus the mediastinal background uptake to the count of 1 mCi technetium-99m under the same acquisition conditions. Then methimazole was stopped and patients were followed. The optimal TTU cutoff value for Graves relapse prediction was calculated using Youden's J statistic. Hyperthyroidism relapsed in 11 (28.9%) patients 122 ± 96 (range: 15-290) days post-ATD withdrawal. The subjects in remission were followed for 209 ± 81 days (range: 88-390). TTU was significantly higher in patients with forthcoming relapse (12.0 ± 8.0 vs. 3.9 ± 2.0, P = .007). The difference was significant after adjustment for age, sex, history of previous relapse, disease duration, and thyroid-stimulating hormone (TSH) levels before withdrawal. The area under the receiver operative characteristic (ROC) curve was 0.87. The optimal TTU cutoff value for classification of subjects with relapse and remission was 8.7 with sensitivity, specificity, and positive and negative predictive value of 73%, 100%, 100%, and 90%, respectively (odds ratio [OR] = 10.0; 95% confidence interval [CI]: 3.4-29.3). TTU evaluation in hyperthyroid patients receiving antithyroid medication is an accurate and practical method for predicting relapse after ATD withdrawal. ATD = antithyroid drugs RIU = radio-iodine uptake TSH = thyroid-stimulating hormone TSI = thyroid-stimulating immunoglobulin TTU = technetium thyroid uptake.

  15. Water-stable fac-{TcO₃}⁺ complexes - a new field of technetium chemistry.

    PubMed

    Braband, Henrik

    2011-01-01

    The development of technetium chemistry has been lagging behind that of its heavier congener rhenium, primarily because the inherent radioactivity of all Tc isotopes has limited the number of laboratories that can study the chemistry of this fascinating element. Although technetium is an artificial element, it is not rare. Significant amounts of the isotope (99)Tc are produced every day as a fission byproduct in nuclear power plants. Therefore, a fundamental understanding of the chemistry of (99)Tc is essential to avoid its release into the environment. In this article the chemistry of technetium at its highest oxidation state (+VII) is reviewed with a special focus on recent developments which make water-stable complexes of the general type [TcO(3)(tacn-R)](+) (tacn-R = 1,4,7-triazacyclononane or derivatives) accessible. Complexes containing the fac-{TcO(3)}(+) core display a unique reactivity. In analogy to [OsO(4)] and [RuO(4)], complexes containing the fac-{TcO(3)}(+) core undergo with alkenes metal-mediated, vicinal cis-dihydroxylation reactions (alkene-glycol interconversion) in water via a (3+2)-cycloaddition reaction. Therefore, water-stable fac-{(99m)TcO(3)}(+) complexes pave the way for a new labeling strategy for radiopharmaceutical applications, based on (3+2)-cycloaddition reactions. This new concept for the labeling of biomolecules with small [(99m)TcO(3)(tacn-R)](+)-type complexes by way of a (3+2)-cycloaddition with alkenes is discussed in detail. The herein reported developments in high-valent technetium chemistry create a new field of research with this artificial element. This demonstrates the potential of fundamental research to provide new impetus of innovation for the development of new methods for radiopharmaceutical applications.

  16. Soft-tissue sarcoma: imaged with technetium-99m pyrophosphate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blatt, C.J.; Hayt, D.B.; Desai, M.

    1977-11-01

    A liposarcoma showed intense concentration of technetium-99m pyrophosphate. An angiogram demonstrated a highly vascular lesion, and it is suggested that blood flow played a major role in allowing the tumor to be demonstrated on scintiphotography. There was some histologic evidence of calcification which probably also contributed to bone-tracer disposition. Quantitative analysis of the specimen demonstrated that this calcification was located primarily in the areas of hemorrhage and necrosis.

  17. Volatile species of technetium and rhenium during waste vitrification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kim, Dongsang; Kruger, Albert A.

    Volatile loss of technetium (Tc) during vitrification of low-activity wastes is a technical challenge for treating and immobilizing the large volumes of radioactive and hazardous wastes stored at the U.S. Department of Energy's Hanford Site. There are various research efforts being pursued to develop technologies that can be implemented for cost effective management of Tc, including studies to understand the behavior of Tc during vitrification, with the goal of eventually increasing Tc retention in glass. Furthermore, one of these studies has focused on identifying the form or species of Tc and Re (surrogate for Tc) that evolve during the waste-to-glassmore » conversion process. This information is important for understanding the mechanism of Tc volatilization. In this paper, available information collected from the literature is critically evaluated to clarify the volatile species of Tc and Re and, more specifically, whether they volatilize as alkali pertechnetate and perrhenate or as technetium and rhenium oxides after decomposition of alkali pertechnetate and perrhenate. The evaluated data ranged from mass spectrometric identification of species volatilized from pure and binary alkali pertechnetate and perrhenate salts to structural and chemical analyses of volatilized materials during crucible melting and scaled melter processing of simulated wastes.« less

  18. Volatile species of technetium and rhenium during waste vitrification

    DOE PAGES

    Kim, Dongsang; Kruger, Albert A.

    2017-10-26

    Volatile loss of technetium (Tc) during vitrification of low-activity wastes is a technical challenge for treating and immobilizing the large volumes of radioactive and hazardous wastes stored at the U.S. Department of Energy's Hanford Site. There are various research efforts being pursued to develop technologies that can be implemented for cost effective management of Tc, including studies to understand the behavior of Tc during vitrification, with the goal of eventually increasing Tc retention in glass. Furthermore, one of these studies has focused on identifying the form or species of Tc and Re (surrogate for Tc) that evolve during the waste-to-glassmore » conversion process. This information is important for understanding the mechanism of Tc volatilization. In this paper, available information collected from the literature is critically evaluated to clarify the volatile species of Tc and Re and, more specifically, whether they volatilize as alkali pertechnetate and perrhenate or as technetium and rhenium oxides after decomposition of alkali pertechnetate and perrhenate. The evaluated data ranged from mass spectrometric identification of species volatilized from pure and binary alkali pertechnetate and perrhenate salts to structural and chemical analyses of volatilized materials during crucible melting and scaled melter processing of simulated wastes.« less

  19. Technetium-99m NGA functional hepatic imaging: preliminary clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Woodle, E.S.

    1985-11-01

    Technetium-99m galactosyl-neoglycoalbumin ( (Tc)NGA) is a radiolabeled ligand to hepatic binding protein, a receptor which resides at the plasma membrane of hepatocytes. This receptor-binding radiopharmaceutical and its kinetic model provide a noninvasive method for the assessment of liver function. Eighteen patients were studied: seven with hepatoma, eight with liver metastases, four with cirrhosis, and one patient with acute fulminant non-A, non-B hepatitis. Technetium-99m NGA liver imaging provided anatomic information of diagnostic quality comparable to that obtained with other routine imaging modalities, including computed tomography, angiography, ultrasound, and (Tc)sulfur colloid scintigraphy. Kinetic modeling of dynamic (Tc)NGA data produced estimates of standardizedmore » hepatic blood flow, Q (hepatic blood flow divided by total blood volume), and hepatic binding protein concentration, (HBP). Significant rank correlation was obtained between (HBP) estimates and CTC scores. This correlation supports the hypothesis that (HBP) is a measure of functional hepatocyte mass. The combination of decreased Q and markedly reduced (HBP) may have prognostic significance; all three patients with this combination died of hepatic failure within 6 wk of imaging.« less

  20. Rhenium and technetium complexes that bind to amyloid-β plaques.

    PubMed

    Hayne, David J; North, Andrea J; Fodero-Tavoletti, Michelle; White, Jonathan M; Hung, Lin W; Rigopoulos, Angela; McLean, Catriona A; Adlard, Paul A; Ackermann, Uwe; Tochon-Danguy, Henri; Villemagne, Victor L; Barnham, Kevin J; Donnelly, Paul S

    2015-03-21

    Alzheimer's disease is associated with the presence of insoluble protein deposits in the brain called amyloid plaques. The major constituent of these deposits is aggregated amyloid-β peptide. Technetium-99m complexes that bind to amyloid-β plaques could provide important diagnostic information on amyloid-β plaque burden using Single Photon Emission Computed Tomography (SPECT). Tridentate ligands with a stilbene functional group were used to form complexes with the fac-[M(I)(CO)3](+) (M = Re or (99m)Tc) core. The rhenium carbonyl complexes with tridentate co-ligands that included a stilbene functional group and a dimethylamino substituent bound to amyloid-β present in human frontal cortex brain tissue from subjects with Alzheimer's disease. This chemistry was extended to make the analogous [(99m)Tc(I)(CO)3](+) complexes and the complexes were sufficiently stable in human serum. Whilst the lipophilicity (log D7.4) of the technetium complexes appeared ideally suited for penetration of the blood-brain barrier, preliminary biodistribution studies in an AD mouse model (APP/PS1) revealed relatively low brain uptake (0.24% ID g(-1) at 2 min post injection).

  1. Effect of Technetium-99 sources on its retention in low activity waste glass

    NASA Astrophysics Data System (ADS)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong; Wang, Guohui; Schweiger, Michael J.; Soderquist, Chuck Z.; Lukens, Wayne; Kruger, Albert A.

    2018-05-01

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO2•2H2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.

  2. Evaluation of Hanford Tank Supernatant Availability for Technetium Management Project Studies in FY16

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rapko, Brian M.

    2015-09-30

    This report examines the need for actual Hanford tank waste solutions to support tasks in the Technetium Management Program in fiscal year (FY) 2016. One key need is to identify both samples where a majority of the soluble technetium is present as pertechnetate and samples where it is not. The total amount of tank supernatant needed from any given tank waste supernatant was determined by polling the tasks leaders for their technology testing needs in FY16 and then arbitrarily ascribing a 10% process loss associated with consolidation and the Cs-137 removal needed to reduce the dose to a level suitablemore » for testing in radiological fumehoods. These polling results identified a need for approximately 2.1 to 3.6 kg of any particular targeted Hanford tank waste supernatant.« less

  3. Determination of technetium-99 in environmental samples: a review.

    PubMed

    Shi, Keliang; Hou, Xiaolin; Roos, Per; Wu, Wangsuo

    2012-01-04

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, (99)Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. (99)Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO(4)(-). A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of (99)Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of (99)Tc. Due to the extremely low concentration of (99)Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of (99)Tc are the most important issues governing the accurate determination of (99)Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for (99)Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of (99)Tc using solid extraction or ion exchange chromatography for separation of (99)Tc, employing flow injection or sequential injection approaches are also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  4. Discovery of rhenium and masurium (technetium) by Ida Noddack-Tacke and Walter Noddack. Forgotten heroes of nuclear medicine.

    PubMed

    Biersack, H-J; Stelzner, F; Knapp, F F

    2015-01-01

    The history of the early identification of elements and their designation to the Mendeleev Table of the Elements was an important chapter in German science in which Ida (1896-1978) and Walter (1893-1960) Noddack played an important role in the first identification of rhenium (element 75, 1925) and technetium (element 43, 1933). In 1934 Ida Noddack was also the first to predict fission of uranium into smaller atoms. Although the Noddacks did not for some time later receive the recognition for the first identification of technetium-99m, their efforts have appropriately more recently been recognized. The discoveries of these early pioneers are even more astounding in light of the limited technologies and resources which were available during this period. The Noddack discoveries of elements 43 and 75 are related to the subsequent use of rhenium-188 (beta/gamma emitter) and technetium-99m (gamma emitter) in nuclear medicine. In particular, the theranostic relationship between these two generator-derived radioisotopes has been demonstrated and offers new opportunities in the current era of personalized medicine.

  5. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE PAGES

    Luksic, Steven A.; Kim, Dong Sang; Um, Wooyong; ...

    2018-03-02

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2∙2H 2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. Here, we postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Finally,more » additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  6. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO2∙2H2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with hexavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Additional studies are neededmore » to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from glass melt.« less

  7. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong Sang; Um, Wooyong

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2∙2H 2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. Here, we postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Finally,more » additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  8. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong

    © 2018 Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2 ∙2H 2 O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generallymore » accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  9. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE PAGES

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong; ...

    2018-05-01

    © 2018 Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2 ∙2H 2 O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generallymore » accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  10. Sensitivity of technetium-99m-pyrophosphate scintigraphy in diagnosing cardiac amyloidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Falk, R.H.; Lee, V.W.; Rubinow, A.

    1983-03-01

    To determine the value of technetium-99m-pyrophosphate myocardial scintigraphy in the diagnosis of amyloid heart disease this procedure was prospectively performed in 20 consecutive patients with biopsy-proven primary amyloidosis. Eleven patients had echocardiographic abnormalities compatible with amyloid cardiomyopathy, 9 of whom had congestive heart failure. Diffuse myocardial pyrophosphate uptake was of equal or greater intensity than that of the ribs in 9 of the 11 patients with echocardiograms suggestive of amyloidosis, but in only 2 of the 9 with normal echocardiograms, despite abnormal electrocardiograms (p less than 0.01). Increased wall thickness measured by M-mode echocardiography correlated with myocardial pyrophosphate uptake (rmore » . 0.68, p less than 0.01). None of 10 control patients with nonamyloid, nonischemic heart disease had a strongly positive myocardial pyrophosphate uptake. Thus, myocardial technetium-99m-pyrophosphate scanning is a sensitive and specific test for the diagnosis of cardiac amyloidosis in patients with congestive heart failure of obscure origin. It does not appear to be of value for the early detection of cardiac involvement in patients with known primary amyloidosis without echocardiographic abnormalities.« less

  11. The corrosion behavior of technetium metal exposed to aqueous sulfate and chloride solutions

    DOE PAGES

    Kolman, David Gary; Goff, George Scott; Cisneros, Michael Ruben; ...

    2017-04-19

    Here, metal waste forms are being studied as possible disposal forms for technetium and other fission products from spent nuclear fuel. As an initial step in assessing the viability of waste forms, technetium corrosion and passivity behavior was assessed across a broad pH spectrum (pH –1 to pH 13). Measurements indicate that the open circuit potential falls into the region of Tc +7 stability, more noble than the region of presumed passivity. Potentiodynamic polarization tests indicate that the Tc samples are not passive. Both electrochemical results and visual inspection suggest the presence of a nonprotective film. The corrosion rate ismore » relatively independent of pH and low, as measured by linear polarization resistance. No evidence of passivity was observed in the Tc +4 region of the potential-pH diagram following in-situ abrasion, suggesting that Tc does not passivate, regardless of potential.« less

  12. The corrosion behavior of technetium metal exposed to aqueous sulfate and chloride solutions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kolman, David Gary; Goff, George Scott; Cisneros, Michael Ruben

    Here, metal waste forms are being studied as possible disposal forms for technetium and other fission products from spent nuclear fuel. As an initial step in assessing the viability of waste forms, technetium corrosion and passivity behavior was assessed across a broad pH spectrum (pH –1 to pH 13). Measurements indicate that the open circuit potential falls into the region of Tc +7 stability, more noble than the region of presumed passivity. Potentiodynamic polarization tests indicate that the Tc samples are not passive. Both electrochemical results and visual inspection suggest the presence of a nonprotective film. The corrosion rate ismore » relatively independent of pH and low, as measured by linear polarization resistance. No evidence of passivity was observed in the Tc +4 region of the potential-pH diagram following in-situ abrasion, suggesting that Tc does not passivate, regardless of potential.« less

  13. Separation of uranium from technetium in recovery of spent nuclear fuel

    DOEpatents

    Pruett, D.J.; McTaggart, D.R.

    1983-08-31

    Uranium and technetium in the product stream of the Purex process for recovery of uranium in spent nuclear fuel are separated by (1) contacting the aqueous Purex product stream with hydrazine to reduce Tc/sup +7/ therein to a reduced species, and (2) contacting said aqueous stream with an organic phase containing tributyl phosphate and an organic diluent to extract uranium from said aqueous stream into said organic phase.

  14. Separation of uranium from technetium in recovery of spent nuclear fuel

    DOEpatents

    Pruett, David J.; McTaggart, Donald R.

    1984-01-01

    Uranium and technetium in the product stream of the Purex process for recovery of uranium in spent nuclear fuel are separated by (1) contacting the aqueous Purex product stream with hydrazine to reduce Tc.sup.+7 therein to a reduced species, and (2) contacting said aqueous stream with an organic phase containing tributyl phosphate and an organic diluent to extract uranium from said aqueous stream into said organic phase.

  15. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children.

    PubMed

    Schofer, O; König, G; Bartels, U; Bockisch, A; Piepenburg, R; Beetz, R; Meyer, G; Hahn, K

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm2 body surface) in addition to normal oral fluid intake, weight-related dose of 99mTc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as "normal" with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (>grade I), no single kidney and no difference in split renal function >20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months.

  16. Intraoperative Injection of Technetium-99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer Patients: A Single Institution Experience.

    PubMed

    Berrocal, Julian; Saperstein, Lawrence; Grube, Baiba; Horowitz, Nina R; Chagpar, Anees B; Killelea, Brigid K; Lannin, Donald R

    2017-01-01

    Background . Most institutions require a patient undergoing sentinel lymph node biopsy to go through nuclear medicine prior to surgery to be injected with radioisotope. This study describes the long-term results using intraoperative injection of radioisotope. Methods . Since late 2002, all patients undergoing a sentinel lymph node biopsy at the Yale-New Haven Breast Center underwent intraoperative injection of technetium-99m sulfur colloid. Endpoints included number of sentinel and nonsentinel lymph nodes obtained and number of positive sentinel and nonsentinel lymph nodes. Results . At least one sentinel lymph node was obtained in 2,333 out of 2,338 cases of sentinel node biopsy for an identification rate of 99.8%. The median number of sentinel nodes found was 2 and the mean was 2.33 (range: 1-15). There were 512 cases (21.9%) in which a sentinel node was positive for metastatic carcinoma. Of the patients with a positive sentinel lymph node who underwent axillary dissection, there were 242 cases (54.2%) with no additional positive nonsentinel lymph nodes. Advantages of intraoperative injection included increased comfort for the patient and simplification of scheduling. There were no radiation related complications. Conclusion . Intraoperative injection of technetium-99m sulfur colloid is convenient, effective, safe, and comfortable for the patient.

  17. Intraoperative Injection of Technetium-99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer Patients: A Single Institution Experience

    PubMed Central

    Berrocal, Julian; Saperstein, Lawrence; Grube, Baiba; Horowitz, Nina R.; Chagpar, Anees B.

    2017-01-01

    Background. Most institutions require a patient undergoing sentinel lymph node biopsy to go through nuclear medicine prior to surgery to be injected with radioisotope. This study describes the long-term results using intraoperative injection of radioisotope. Methods. Since late 2002, all patients undergoing a sentinel lymph node biopsy at the Yale-New Haven Breast Center underwent intraoperative injection of technetium-99m sulfur colloid. Endpoints included number of sentinel and nonsentinel lymph nodes obtained and number of positive sentinel and nonsentinel lymph nodes. Results. At least one sentinel lymph node was obtained in 2,333 out of 2,338 cases of sentinel node biopsy for an identification rate of 99.8%. The median number of sentinel nodes found was 2 and the mean was 2.33 (range: 1–15). There were 512 cases (21.9%) in which a sentinel node was positive for metastatic carcinoma. Of the patients with a positive sentinel lymph node who underwent axillary dissection, there were 242 cases (54.2%) with no additional positive nonsentinel lymph nodes. Advantages of intraoperative injection included increased comfort for the patient and simplification of scheduling. There were no radiation related complications. Conclusion. Intraoperative injection of technetium-99m sulfur colloid is convenient, effective, safe, and comfortable for the patient. PMID:28492062

  18. Identification of neutron deficient niobium, molybdenum and technetium isotopes

    NASA Astrophysics Data System (ADS)

    Gross, C. J.

    We report on the in-beam identification of fourteen new isotopes in the A=80-90 region. Heavy-ion reactions with a recoil separator or charged particle and neutron detectors provided identification of γ-rays from these new niobium, molybdenum, and technetium isotopes. The procedures used are described and energy level systematics are discussed. The energy levels appear to be organized into rotational bands in nuclei with N≤44 while those with N ≥ 46 have more single-particle-like transitions. Lifetime measurements in 87Mo and 87Nb indicate that g {9}/{2} particle alignment strongly influences the collectivity of these nuclei.

  19. Toward hypoxia-selective rhenium and technetium tricarbonyl complexes.

    PubMed

    North, Andrea J; Hayne, David J; Schieber, Christine; Price, Katherine; White, Anthony R; Crouch, Peter J; Rigopoulos, Angela; O'Keefe, Graeme J; Tochon-Danguy, Henri; Scott, Andrew M; White, Jonathan M; Ackermann, Uwe; Donnelly, Paul S

    2015-10-05

    With the aim of preparing hypoxia-selective imaging and therapeutic agents, technetium(I) and rhenium(I) tricarbonyl complexes with pyridylhydrazone, dipyridylamine, and pyridylaminocarboxylate ligands containing nitrobenzyl or nitroimidazole functional groups have been prepared. The rhenium tricarbonyl complexes were synthesized with short reaction times using microwave irradiation. Rhenium tricarbonyl complexes with deprotonated p-nitrophenyl pyridylhydrazone ligands are luminescent, and this has been used to track their uptake in HeLa cells using confocal fluorescent microscopy. Selected rhenium tricarbonyl complexes displayed higher uptake in hypoxic cells when compared to normoxic cells. A (99m)Tc tricarbonyl complex with a dipyridylamine ligand bearing a nitroimidazole functional group is stable in human serum and was shown to localize in a human renal cell carcinoma (RCC; SK-RC-52) tumor in a mouse.

  20. Technetium Getters to Improve Cast Stone Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neeway, James J.; Lawter, Amanda R.; Serne, R. Jeffrey

    2015-10-15

    The cementitious material known as Cast Stone has been selected as the preferred waste form for solidification of aqueous secondary liquid effluents from the Hanford Tank Waste Treatment and Immobilization Plant (WTP) process condensates and low-activity waste (LAW) melter off-gas caustic scrubber effluents. Cast Stone is also being evaluated as a supplemental immobilization technology to provide the necessary LAW treatment capacity to complete the Hanford tank waste cleanup mission in a timely and cost effective manner. Two radionuclides of particular concern in these waste streams are technetium-99 (99Tc) and iodine-129 (129I). These radioactive tank waste components contribute the most tomore » the environmental impacts associated with the cleanup of the Hanford site. A recent environmental assessment of Cast Stone performance, which assumes a diffusion controlled release of contaminants from the waste form, calculates groundwater in excess of the allowable maximum permissible concentrations for both contaminants. There is, therefore, a need and an opportunity to improve the retention of both 99Tc and 129I in Cast Stone. One method to improve the performance of Cast Stone is through the addition of “getters” that selectively sequester Tc and I, therefore reducing their diffusion out of Cast Stone. In this paper, we present results of Tc and I removal from solution with various getters with batch sorption experiments conducted in deionized water (DIW) and a highly caustic 7.8 M Na Ave LAW simulant. In general, the data show that the selected getters are effective in DIW but their performance is comprised when experiments are performed with the 7.8 M Na Ave LAW simulant. Reasons for the mitigated performance in the LAW simulant may be due to competition with Cr present in the 7.8 M Na Ave LAW simulant and to a pH effect.« less

  1. Extraction processes and solvents for recovery of cesium, strontium, rare earth elements, technetium and actinides from liquid radioactive waste

    DOEpatents

    Zaitsev, Boris N.; Esimantovskiy, Vyacheslav M.; Lazarev, Leonard N.; Dzekun, Evgeniy G.; Romanovskiy, Valeriy N.; Todd, Terry A.; Brewer, Ken N.; Herbst, Ronald S.; Law, Jack D.

    2001-01-01

    Cesium and strontium are extracted from aqueous acidic radioactive waste containing rare earth elements, technetium and actinides, by contacting the waste with a composition of a complex organoboron compound and polyethylene glycol in an organofluorine diluent mixture. In a preferred embodiment the complex organoboron compound is chlorinated cobalt dicarbollide, the polyethylene glycol has the formula RC.sub.6 H.sub.4 (OCH.sub.2 CH.sub.2).sub.n OH, and the organofluorine diluent is a mixture of bis-tetrafluoropropyl ether of diethylene glycol with at least one of bis-tetrafluoropropyl ether of ethylene glycol and bis-tetrafluoropropyl formal. The rare earths, technetium and the actinides (especially uranium, plutonium and americium), are extracted from the aqueous phase using a phosphine oxide in a hydrocarbon diluent, and reextracted from the resulting organic phase into an aqueous phase by using a suitable strip reagent.

  2. The discovery of robust magnetism in a technetium oxide: The structure of CaTcO3

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Avdeev, Maxim; Thorogood, Gordon J.; Carter, Melody L.

    The technetium perovskite CaTcO{sub 3} has been synthesized. Combining synchrotron X-ray and neutron diffraction, we found that CaTcO{sub 3} is an antiferromagnetic with a surprisingly high Neel temperature of 800 K. The transition to the magnetic state does not involve a structural change, but there is obvious magnetostriction. Electronic structure calculations confirm the experimental results.

  3. Technetium phosphate bone scan in the diagnosis of septic arthritis in childhood

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sundberg, S.B.; Savage, J.P.; Foster, B.K.

    1989-09-01

    The technetium phosphate bone scans of 106 children with suspected septic arthritis were reviewed to determine whether the bone scan can accurately differentiate septic from nonseptic arthropathy. Only 13% of children with proved septic arthritis had correct blind scan interpretation. The clinically adjusted interpretation did not identify septic arthritis in 30%. Septic arthritis was incorrectly identified in 32% of children with no evidence of septic arthritis. No statistically significant differences were noted between the scan findings in the septic and nonseptic groups and no scan findings correlated specifically with the presence or absence of joint sepsis.

  4. Tellurite glasses for vitrification of technetium-99 from pyrochemical processing

    NASA Astrophysics Data System (ADS)

    Pyo, Jae-Young; Lee, Cheong Won; Park, Hwan-Seo; Yang, Jae Hwan; Um, Wooyong; Heo, Jong

    2017-09-01

    A new alkali-alumino tellurite glass composition was developed to immobilize highly-volatile technetium (Tc) wastes generated from the pyrochemical processing technology. Tellurite glass can incorporate up to 7 mass% of rhenium (Re, used as a surrogate for Tc) with an average retention of 86%. Normalized elemental releases evaluated by seven-day product consistency test (PCT) satisfied the immobilized low activity waste requirements of United States when concentration of Ca(ReO4)2 in the glass was <12 mass%. Re ions form Re7+ and are coordinated with four oxygens to form ReO4- tetrahedra. These tetrahedra bond to modifiers such as Ca2+ or Na+ that are further connected to the tellurite glass network by Ca2+ (or Na+) - non-bridging oxygen bonds.

  5. The abdominal technetium scan (a decade of experience)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooney, D.R.; Duszynski, D.O.; Camboa, E.

    1982-10-01

    Out of 270 children with gastrointestinal symptoms, the indications for technetium scanning were: gastrointestinal tract bleeding (165 patients), abdominal pain (99 patients) and a history of intussusception (6 patients). Thirty children had abnormal findings, while the remaining 240 patients had normal scans. Four of the 30 children with positive scans were not explored, while the others underwent laparotomy. Of the 26 operated patients, 12 (46%) had a Meckel's diverticulum. Nine patients (34%) had other pathologic lesions that were detected by the scan. Five had true false positives as no pathologic lesions were found. Of the 240 children with negative scans,more » 19 were eventually explored because of persistent symptoms or clinical findings. Two of these had a Meckel's diverticulum. Eleven had a negative exploration while six had other surgical lesions. Technitium scan should reliably detect around 80%-90% of Meckel's diverticula. It will also accurately exclude the diagnosis of Meckel's diverticulum in over 90% of patients.« less

  6. Periarticular uptake of /sup 99m/technetium diphosphonate in psoriatics. Correlation with cutaneous activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Namey, T.C.; Rosenthall, L.

    1976-01-01

    The periarticular uptake of /sup 99m/technetium-labeled diphosphonate (/sup 99m/TcDP) was compared in 12 patients hospitalized for psoriasis and in 12 hospitalized for other dermatoses not associated with arthropathy. The 12 patients with psoriasis had recent onset disease of less than 5 years duration; neither group had historical or clinical evidence of arthritis. All psoriatics had markedly abnormal scans with symmetrically increased periarticular uptake about the imaged joints. None of the controls had similar findings. In 4 patients scanned with /sup 99m/technetium-pertechnetate within 24 hours of their /sup 99m/TcDP scan, no evidence of inflammatory synovitis was found. Three of these patientsmore » were serially imaged with /sup 99m/TcDP at intervals of 2 weeks to 3 months after their initial study, when obvious clinical improvement in their psoriasis was apparent. Improvement in the radionuclide joint images was demonstrated in some of the patients, but none reverted to normal during the study period. In light of recent evidence for the preferential binding of /sup 99m/TcDP to immature collagen, it is suggested that psoriasis may represent a generalized, but uncharacterized, collagen disorder present in bone as well as skin, linking the cutaneous disease with the potential for arthropathy.« less

  7. Ion Exchange Distribution Coefficient Tests and Computer Modeling at High Ionic Strength Supporting Technetium Removal Resin Maturation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, Charles A.; Hamm, L. Larry; Smith, Frank G.

    2014-12-19

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant (WTP) that is currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and poured into canisters for disposition. The LAW glass will be disposed onsite in the Integrated Disposal Facility (IDF). There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Duemore » to the water solubility properties of pertechnetate and long half-life of 99Tc, effective management of 99Tc is important to the overall success of the Hanford River Protection Project mission. To achieve the full target WTP throughput, additional LAW immobilization capacity is needed, and options are being explored to immobilize the supplemental LAW portion of the tank waste. Removal of 99Tc, followed by off-site disposal, would eliminate a key risk contributor for the IDF Performance Assessment (PA) for supplemental waste forms, and has potential to reduce treatment and disposal costs. Washington River Protection Solutions (WRPS) is developing some conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal. One of these flowsheets will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. To enable an informed decision regarding the viability of technetium removal, further maturation of available technologies is being performed. This report contains results of experimental ion exchange distribution coefficient testing and computer modeling using the resin SuperLig ® 639 a to selectively remove perrhenate from high ionic strength simulated LAW. It is advantageous to operate at higher concentration in order to treat the waste stream without dilution and to minimize the volume of the

  8. Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, C.; McCabe, D.; Hamm, L.

    2013-12-20

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life ofmore » 99Tc, effective management of 99Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99Tc during the vitrification process. Removal of 99Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99Tc is predominantly found in the tank supernate as pertechnetate (TcO 4 -). Perrhenate (ReO 4 -) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of SuperLig® 639 resin has good performance, with an average perrhenate distribution coefficient of

  9. Structural stability and mechanical properties of technetium mononitride (TcN)

    NASA Astrophysics Data System (ADS)

    Soni, Shubhangi; Choudhary, K. K.; Kaurav, Netram

    2018-05-01

    Among the nitrides, 3d and 4d transition metal nitrides have been investigated both experimentally and theoretically due to their predominant performances and enormous applications. In the present paper, we have attempted to predict the structural stability and mechanical properties of technetium mononitride (TcN) using an effective interionic interaction potential, which includes the long range Coulomb, van der Waals (vdW) interaction and the short-range repulsive interaction upto second-neighbor ions within the Hafemeister and Flygare approach. Our theoretical approach reveals the structural phase transition of the TcN B3 to B1 structure, wherein, the Gibbs' free energies of both the structures were minimized. The variations of elastic constants with pressure follow a systematic trend identical to that observed in other compounds of ZnS type structure family.

  10. Scintigraphic detection of occult hemorrhage using RBCs labeled in vitro with technetium Tc 99m sodium pertechnetate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bunker, S.R.; Kolina, J.S.; Kaplan, K.A.

    1983-05-01

    Scintigraphy with RBCs labeled with technetium Tc 99m sodium pertechnetate effectively located the source of hemorrhage in a patient receiving long-term anticoagulant therapy. (The patient was initially seen with a large hematoma on the flank.) More important, the procedure was used to monitor activity in this otherwise-occult bleeding site. Scintigraphic studies may be useful in the management of these difficult clinical problems.

  11. Immobilization of Technetium in a Metallic Waste Form

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    S.M. Frank; D. D. Keiser, Jr.; K. C. Marsden

    Fission-product technetium accumulated during treatment of spent nuclear fuel will ultimately be disposed of in a geological repository. The exact form of Tc for disposal has yet to be determined; however, a reasonable solution is to incorporate elemental Tc into a metallic waste form similar to the waste form produced during the pyrochemical treatment of spent, sodium-bonded fuel. This metal waste form, produced at the Idaho National Laboratory, has undergone extensive qualification examination and testing for acceptance to the Yucca Mountain geological repository. It is from this extensive qualification effort that the behavior of Tc and other fission products inmore » the waste form has been elucidated, and that the metal waste form is extremely robust in the retention of fission products, such as Tc, in repository like conditions. This manuscript will describe the metal waste form, the behavior of Tc in the waste form; and current research aimed at determining the maximum possible loading of Tc into the metal waste and subsequent determination of the performance of high Tc loaded metal waste forms.« less

  12. Technetium-99m stannous pyrophosphate myocardial scintigraphy after cardiopulmonary resuscitation with cardioversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davison, R.; Spies, S.M.; Przybylek, J.

    1979-08-01

    Thirty consecutive patients underwent technetium-99m stannous pyrophosphate myocardial scintigraphy 48 to 72 h after successful cardiopulmonary resuscitation and direct current cardioversion. Five patients with transmural myocardial infarctions by ECG and enzyme determinations were correctly identified by scintigraphy. Myocardial scans were positive in five of nine patients with nontransmural infarction. Of 16 patients without evidence of myocardial infarction, only two (13%) had false-positive myocardial scans. The overall accuracy of imaging in this series was 80%. We conclude that false-positive scans after cardiopulmonary resuscitation with electrical cardioversion are infrequent, and do not significantly detract from the value of myocardial scintigraphy in themore » diagnosis of myocardial infarction.« less

  13. Development of a remote spectroelectrochemical sensor for technetium as pertechnetate

    NASA Astrophysics Data System (ADS)

    Monk, David James

    Subsurface contamination by technetium (Tc) is of particular concern in the monitoring, characterization, and remediation of underground nuclear waste storage tanks, processing areas, and associated surroundings at the Hanford Site and other U.S. DOE sites nationwide. The concern over this radioactive element arises for two reasons. First, its most common isotope, 99Tc, has an extremely long lifetime of 2.15 x 105 years. Second, it's most common chemical form in environmental conditions, pertechnetate (TcO4-), exhibits very fast migration through soils and readily presents itself to any nearby aquifer. Standard procedures of sampling and analysis in a laboratory prove to be slow and costly in the case of subsurface contamination by radioactive materials. It is highly desirable to develop sensors for these materials that possess the capability of either in-situ or on-site placement for continuous monitoring or immediate analysis of collected samples. These sensors need to possess adequate detection limit and selectivity, rapid response, reversibility (many measurements with one sensor), the ability to perform remotely, and ruggedness. This dissertation describes several areas of the continued work toward a sensor for 99Tc as TcO4-. Research initially focused on developing spectroelectrochemical instrumentation and a disposable sensing element, engineered to address the need to perform remote measurements. The instrument was then tested using samples containing 99Tc, resulting in the development of ancillary equipment and techniques to address concerns associated with performing experiments on radioactive materials. In these tests, the electrochemistry of TcO4 - was demonstrated to be irreversible. Electrochemical reduction of TcO4- on a bare or polymer modified electrode resulted in the continuous build up of technetium oxide (TcO2) on the electrode surface. This TcO2 formed in visual quantities in these films during electrochemistry, and proved to be non-ideal for

  14. Importance of methodology on (99m)technetium dimercapto-succinic acid scintigraphic image quality: imaging pilot study for RIVUR (Randomized Intervention for Children With Vesicoureteral Reflux) multicenter investigation.

    PubMed

    Ziessman, Harvey A; Majd, Massoud

    2009-07-01

    We reviewed our experience with (99m)technetium dimercapto-succinic acid scintigraphy obtained during an imaging pilot study for a multicenter investigation (Randomized Intervention for Children With Vesicoureteral Reflux) of the effectiveness of daily antimicrobial prophylaxis for preventing recurrent urinary tract infection and renal scarring. We analyzed imaging methodology and its relation to diagnostic image quality. (99m)Technetium dimercapto-succinic acid imaging guidelines were provided to participating sites. High-resolution planar imaging with parallel hole or pinhole collimation was required. Two core reviewers evaluated all submitted images. Analysis included appropriate views, presence or lack of patient motion, adequate magnification, sufficient counts and diagnostic image quality. Inter-reader agreement was evaluated. We evaluated 70, (99m)technetium dimercapto-succinic acid studies from 14 institutions. Variability was noted in methodology and image quality. Correlation (r value) between dose administered and patient age was 0.780. For parallel hole collimator imaging good correlation was noted between activity administered and counts (r = 0.800). For pinhole imaging the correlation was poor (r = 0.110). A total of 10 studies (17%) were rejected for quality issues of motion, kidney overlap, inadequate magnification, inadequate counts and poor quality images. The submitting institution was informed and provided with recommendations for improving quality, and resubmission of another study was required. Only 4 studies (6%) were judged differently by the 2 reviewers, and the differences were minor. Methodology and image quality for (99m)technetium dimercapto-succinic acid scintigraphy varied more than expected between institutions. The most common reason for poor image quality was inadequate count acquisition with insufficient attention to the tradeoff between administered dose, length of image acquisition, start time of imaging and resulting image

  15. Combined technetium radioisotope penile plethysmography and xenon washout: A technique for evaluating corpora cavernosal inflow and outflow during early tumescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, A.N.; Graham, M.M.

    1991-03-01

    Combined technetium radioisotope penile plethysmography and xenon washout is a new technique that measures both corporal arterial inflow and venous sinusoidal outflow during early tumescence in patients with erectile dysfunction. Fourteen patients were studied using 99mTc-RBCs to measure inflow and 133Xe or 127Xe in saline to measure outflow. Tumescence was induced by injecting papaverine intracorporally. Peak corporal rates corrected for inflow (r = 0.88) and uncorrected for outflow (r = 0.91) and change in volume over 2 min centered around peak inflow (r = 0.96) all correlated with angiography. Outflow measurements did not correlate with intracorporal resistance. Thus, outflow ratesmore » alone could not be used to predict venous sinusoidal competence. Normal inflow rate is greater than 20 ml/min; probable normal 12-20; indeterminate inflow 7-12; and abnormal inflow less than 7 ml/min. Technetium-99m radioisotope penile plethysmography and xenon washout can be performed together and both provide a method for simultaneously evaluating the relationship between corporal inflow and outflow rates in patients with erectile dysfunction.« less

  16. Incorporating technetium in minerals and other solids: A review

    NASA Astrophysics Data System (ADS)

    Luksic, Steven A.; Riley, Brian J.; Schweiger, Michael; Hrma, Pavel

    2015-11-01

    Technetium (Tc) can be incorporated into a number of different solids including spinel, sodalite, rutile, tin dioxide, pyrochlore, perovskite, goethite, layered double hydroxides, cements, and alloys. Synthetic routes are possible for each of these phases, ranging from high-temperature ceramic sintering to ball-milling of constituent oxides. However, in practice, Tc has only been incorporated into solid materials by a limited number of the possible syntheses. A review of the diverse ways in which Tc-immobilizing materials can be made shows the wide range of options available. Special consideration is given to hypothetical application to the Hanford Tank Waste and Vitrification Plant, such as adding a Tc-bearing mineral to waste glass melter feed. A full survey of solid Tc waste forms, the common synthesis routes to those waste forms, and their potential for application to vitrification processes are presented. The use of tin dioxide or ferrite spinel precursors to reduce Tc(VII) out of solution and into a durable form are shown to be of especially high potential.

  17. Recovery and Determination of Adsorbed Technetium on Savannah River Site Charcoal Stack Samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lahoda, Kristy G.; Engelmann, Mark D.; Farmer, Orville T.

    2008-03-01

    Experimental results are provided for the sample analyses for technetium (Tc) in charcoal samples placed in-line with a Savannah River Site (SRS) processing stack effluent stream as a part of an environmental surveillance program. The method for Tc removal from charcoal was based on that originally developed with high purity charcoal. Presented is the process that allowed for the quantitative analysis of 99Tc in SRS charcoal stack samples with and without 97Tc as a tracer. The results obtained with the method using the 97Tc tracer quantitatively confirm the results obtained with no tracer added. All samples contain 99Tc at themore » pg g-1 level.« less

  18. Literature review of the potential impact of glycolic acid on the technetium chemistry of srs tank waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, Charles A.; McCabe, Daniel J.

    This document presents a literature study of the impact of glycolate on technetium chemistry in the Savannah River Site (SRS) waste system and specifically Saltstone. A predominant portion of the Tc at SRS will be sent to the Saltstone Facility where it will be immobilized. The Tc in the tank waste is in the highly soluble chemical form of pertechnetate ion (TcO 4 -) which is reduced by blast furnace slag (BFS) in Saltstone, rendering it highly insoluble and resistant to leaching.

  19. The role of technetium-99m stannous pyrophosphate in myocardial imaging to recognize, localize and identify extension of acute myocardial infarction in patients

    NASA Technical Reports Server (NTRS)

    Willerson, J. T.; Parkey, R. W.; Bonte, F. J.; Stokely, E. M.; Buja, E. M.

    1975-01-01

    The ability of technetium-99m stannous pyrophosphate myocardial scintigrams to aid diagnostically in recognizing, localizing, and identifying extension of acute myocardial infarction in patients was evaluated. The present study is an extension of previous animal and patient evaluations that were recently performed utilizing this myocardial imaging agent.

  20. Rhenium solubility in borosilicate nuclear waste glass: implications for the processing and immobilization of technetium-99.

    PubMed

    McCloy, John S; Riley, Brian J; Goel, Ashutosh; Liezers, Martin; Schweiger, Michael J; Rodriguez, Carmen P; Hrma, Pavel; Kim, Dong-Sang; Lukens, Wayne W; Kruger, Albert A

    2012-11-20

    The immobilization of technetium-99 ((99)Tc) in a suitable host matrix has proven to be a challenging task for researchers in the nuclear waste community around the world. In this context, the present work reports on the solubility and retention of rhenium, a nonradioactive surrogate for (99)Tc, in a sodium borosilicate glass. Glasses containing target Re concentrations from 0 to 10,000 ppm [by mass, added as KReO(4) (Re(7+))] were synthesized in vacuum-sealed quartz ampules to minimize the loss of Re from volatilization during melting at 1000 °C. The rhenium was found as Re(7+) in all of the glasses as observed by X-ray absorption near-edge structure. The solubility of Re in borosilicate glasses was determined to be ~3000 ppm (by mass) using inductively coupled plasma optical emission spectroscopy. At higher rhenium concentrations, additional rhenium was retained in the glasses as crystalline inclusions of alkali perrhenates detected with X-ray diffraction. Since (99)Tc concentrations in a glass waste form are predicted to be <10 ppm (by mass), these Re results implied that the solubility should not be a limiting factor in processing radioactive wastes, assuming Tc as Tc(7+) and similarities between Re(7+) and Tc(7+) behavior in this glass system.

  1. Detection of homing-in of stem cells labeled with technetium-99m hexamethylpropyleneamine oxime in infarcted myocardium after intracoronary injection

    PubMed Central

    Patel, Chetan D; Agarwal, Snehlata; Seth, Sandeep; Mohanty, Sujata; Aggarwal, Himesh; Gupta, Namit

    2014-01-01

    Bone marrow stem cells having myogenic potential are promising candidates for various cell-based therapies for myocardial disease. We present here images showing homing of technetium-99m (Tc-99m) hexamethylpropyleneamine oxime (HMPAO) labeled stem cells in the infarcted myocardium from a pilot study conducted to radio-label part of the stem cells in patients enrolled in a stem cell clinical trial for recent myocardial infarction. PMID:25400375

  2. Fast dynamic electron transfer along infinite anion-cation chains in technetium and rhenium acido clusters

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Antipov, B.G.; Kryuchkov, S.V.; Grigor`ev, M.S.

    1995-09-01

    New technetium and rhenium compounds with ferricenium cations - [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 3}[Tc{sub 6}I{sub 14}], [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 3}[Tc{sub 6}Cl{sub 14}], [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 2}[Tc{sub 8}Br{sub 14}], and [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 2}[Re{sub 2}Br{sub 8}] - are synthesized and identified. The compounds are characterized by the methods of static magnetic susceptibility and differential scanning calorimetry; solid-state conductivity measurements; and IR, EPR, {sup 57}Fe Moessbauer, and X-ray photoelectron spectroscopic data. These data are compared with the physicochemical characteristics of ferricenium pertechnetate and hexachlorotechnetate, as well as of a number of reference technetium and rhenium compounds containing the samemore » anions but different cations. The structure of [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 3}[Tc{sub 6}I{sub 14}] is determined by X-ray diffraction analysis of a single crystal [space group P6/m, a = 15.34(2), c = 12.70(1) {angstrom}]. The structures of the remaining compounds were confirmed by comparing their spectroscopic properties with corresponding properties of compounds with known composition and structure. None of the compounds with ferricenium cations exhibit covalent or other localized bonds between anions and cations. However, the physicochemical properties of these compounds indicate the occurrence of a fast dynamic electron transfer along infinite anion-cation chains. Compounds [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 3}[Tc{sub 6}Cl{sub 14}] and [Fe(C{sub 5}H{sub 5}){sub 2}]{sub 2}[Tc{sub 8}Br{sub 14}] were found to exhibit a new phenomenon of X-ray-induced low-temper ature high-energy electron emission.« less

  3. LABORATORY OPTIMIZATION TESTS OF TECHNETIUM DECONTAMINATION OF HANFORD WASTE TREATMENT PLANT LOW ACTIVITY WASTE OFF-GAS CONDENSATE SIMULANT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor-Pashow, K.; Nash, C.; McCabe, D.

    2014-09-29

    compatible with longterm tank storage and immobilization methods. For this new application, testing is needed to demonstrate acceptable treatment sorbents and precipitating agents and measure decontamination factors for additional radionuclides in this unique waste stream. The origin of this LAW Off-Gas Condensate stream will be the liquids from the Submerged Bed Scrubber (SBS) and the Wet Electrostatic Precipitator (WESP) from the LAW melter off-gas system. The stream is expected to be a dilute salt solution with near neutral pH, and will likely contain some insoluble solids from melter carryover. The soluble components are expected to be mostly sodium and ammonium salts of nitrate, chloride, and fluoride. This stream has not been generated yet and will not be available until the WTP begins operation, but a simulant has been produced based on models, calculations, and comparison with pilot-scale tests. One of the radionuclides that is volatile and expected to be in greatest abundance in this LAW Off-Gas Condensate stream is Technetium-99 ({sup 99}Tc). Technetium will not be removed from the aqueous waste in the Hanford WTP, and will primarily end up immobilized in the LAW glass by repeated recycle of the off-gas condensate into the LAW melter. Other radionuclides that are low but are also expected to be in measurable concentration in the LAW Off-Gas Condensate are {sup 129}I, {sup 90}Sr, {sup 137}Cs, {sup 241}Pu, and {sup 241}Am. These are present due to their partial volatility and some entrainment in the off-gas system. This report discusses results of optimized {sup 99}Tc decontamination testing of the simulant. Testing examined use of inorganic reducing agents for {sup 99}Tc. Testing focused on minimizing the quantity of sorbents/reactants added, and minimizing mixing time to reach the decontamination targets in this simulant formulation. Stannous chloride and ferrous sulfate were tested as reducing agents to determine the minimum needed to convert soluble pertechnetate

  4. Ab-initio study of B{sub 2}-type technetium AB (A=Tc, B=Nb and Ta) intermetallic compounds

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Acharya, Nikita, E-mail: acharyaniks30@gmail.com; Fatima, Bushra; Sanyal, Sankar P.

    2016-05-06

    The structural, electronic and elastic properties of AB type (A = Tc, B = Nb and Ta) technetium intermetallic compounds are studied using full potential linearized plane wave (FP-LAPW) method within generalized gradient approximation (GGA). The calculated lattice parameters agree well with the experimental results. The elastic constants obey the stability criteria for cubic system. Ductility for these compounds has been analyzed using the Pugh’s rule and Cauchy’s pressure and found that all the compounds are ductile in nature. Bonding nature is discussed in terms of Fermi surface and band structures.

  5. Eosinophilic enterocolitis diagnosed by means of technetium-99m albumin scintigraphy and treated with budesonide (CIR).

    PubMed Central

    Russel, M G; Zeijen, R N; Brummer, R J; de Bruine, A P; van Kroonenburgh, M J; Stockbrügger, R W

    1994-01-01

    A patient with a 15 year history of diarrhoea of unknown origin is described. Scintigraphy with technetium-99m labelled albumin suggested albumin loss at the terminal ileum and caecum; subsequent colonoscopic biopsies of these macroscopically normal looking areas showed abundant infiltration with eosinophils. A diagnosis of eosinophilic enterocolitis was made. Treatment with prednisolone had good results, but had to be stopped because of severe side effects. Oral cromoglycate and mesalazine were not effective. Budesonide (CIR), a new topically active corticosteroid with very little systemic effects, was at least as effective as prednisolone without producing side effects. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:7959211

  6. Technetium-99m production issues in the United Kingdom.

    PubMed

    Green, Christopher H

    2012-04-01

    Nuclear Medicine developed when it was realised that a radioisotopic substitution of Iodine-131 for the stable Iodine-127 would follow the same metabolic pathway in the body enabling the thyroid to be imaged and the thyroid uptake measured. The Iodine could be complexed with pharmaceutical substrates to enable other organs to be imaged, but its use was limited and high gamma energy and beta emission restricted the activity of each radiopharmaceutical used, leading to long acquisition times and degraded images. As a pure gamma emitter of 140 keV and with a 6-h half-life, Technetium-99m is a better radionuclide and images a wider range of bodily organs. However, its short half-life also requires it to be eluted from its mother radionuclide, Mo-99, in a generator, delivered weekly from radiopharmaceutical companies who obtain the Mo-99 in liquid form from high-flux research reactors. All went well till around 2007, when the NRU Reactor in Canada was closed and all other reactors went down for various periods for unrelated problems, leading to widespread Mo-99 shortages. Although the reactors have since recovered, they are 48 to 57 years old, and it seems that few governments have made any future provision such as building replacement reactors.

  7. Technetium-99m production issues in the United Kingdom

    PubMed Central

    Green, Christopher H.

    2012-01-01

    Nuclear Medicine developed when it was realised that a radioisotopic substitution of Iodine-131 for the stable Iodine-127 would follow the same metabolic pathway in the body enabling the thyroid to be imaged and the thyroid uptake measured. The Iodine could be complexed with pharmaceutical substrates to enable other organs to be imaged, but its use was limited and high gamma energy and beta emission restricted the activity of each radiopharmaceutical used, leading to long acquisition times and degraded images. As a pure gamma emitter of 140 keV and with a 6-h half-life, Technetium-99m is a better radionuclide and images a wider range of bodily organs. However, its short half-life also requires it to be eluted from its mother radionuclide, Mo-99, in a generator, delivered weekly from radiopharmaceutical companies who obtain the Mo-99 in liquid form from high-flux research reactors. All went well till around 2007, when the NRU Reactor in Canada was closed and all other reactors went down for various periods for unrelated problems, leading to widespread Mo-99 shortages. Although the reactors have since recovered, they are 48 to 57 years old, and it seems that few governments have made any future provision such as building replacement reactors. PMID:22557795

  8. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    PubMed

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  9. Technetium-99m-labeled ceftizoxime loaded long-circulating and pH-sensitive liposomes used to identify osteomyelitis.

    PubMed

    Ferreira, Soraya Maria Zandim Maciel Dias; Domingos, Giselle Pires; Ferreira, Diego dos Santos; Rocha, Talita Guieiro Ribeiro; Serakides, Rogéria; de Faria Rezende, Cleuza Maria; Cardoso, Valbert Nascimento; Fernandes, Simone Odília Antunes; Oliveira, Mônica Cristina

    2012-07-15

    Osteomyelitis is an infectious disease located in the bone or bone marrow. Long-circulating and pH-sensitive liposomes containing a technetium-99m-labeled antibiotic, ceftizoxime, (SpHL-(99m)Tc-CF) were developed to identify osteomyelitis foci. Biodistribution studies and scintigraphic images of bone infection or non infection-bearing rats that had been treated with these liposomes were performed. A high accumulation in infectious foci and high values in the target-non target ratio could be observed. These results indicate the potential of SpHL-(99m)Tc-CF as a potential agent for the diagnosis of bone infections. Copyright © 2012 Elsevier Ltd. All rights reserved.

  10. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    PubMed

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P < 0.001 and r = 0.94, P < 0.001). The preoperative and postoperative split estimated glomerular filtration rate of the operated kidney showed a moderate correlation with split renal function (r = 0.39, P = 0.004 and r = 0.49, P < 0.001). The correlation between reductions in split renal function and split renal volume of the operated kidney (r = 0.87, P < 0.001) was stronger than that between split renal function and percent reduction in split estimated glomerular filtration rate (r = 0.64, P < 0.001). The split renal volume calculated using computed tomography-based renal volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  11. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    PubMed

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  12. On the absence of young white dwarf companions to five technetium stars

    NASA Technical Reports Server (NTRS)

    Smith, Verne V.; Lambert, David L.

    1987-01-01

    A search for hot companions to five stars of type MS and S has been carried out using the IUE satellite. No hot companions were detected for the MS stars HR 85, 4647, 6702, and 8062, and the S star HR 8714. Limits on the luminosities of possible white dwarf companions provide lower limits of 2-5x10 to the 8th yr to the ages of any degenerate companions. All five stars exhibit strong Tc I lines, and the presence of technetium, with a half-life of 2.1x10 to the 5th yr, signifies recent nucleosynthesis. The limits on the ages of possible white dwarf companions that are equal to or greater than 1000 half-lives of Tc exclude the possibility that the s-process elemental enhancement seen in these MS and S stars resulted from mass transfer from a more highly evolved companion (as is probably the mechanism by which barium stars are created). These MS and S stars represent a sample of true thermally pulsing asymptotic giant-branch stars.

  13. EVALUATION OF VADOSE ZONE TREATMENT TECHNOLOGIES TO IMMOBILIZE TECHNETIUM-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PETERSEN, S.W.

    2006-03-15

    The Hanford Site End State Vision document (DOE/RL-2003-59) states: ''There should be an aggressive plan to develop technology for remediation of the contamination that could get to the groundwater (particularly the technetium [{sup 99}Tc])''. In addition, there is strong support from the public and regulatory agencies for the above statement, with emphasis on investigation of treatment alternatives. In July 2004, PNNL completed a preliminary evaluation of remediation technologies with respect to their effectiveness and implementability for immobilization of {sup 99}Tc beneath the BC Cribs in the 200 West Area (Truex, 2004). As a result of this evaluation, PNNL recommended treatabilitymore » testing of in situ soil desiccation, because it has the least uncertainty of those technologies evaluated in July 2004 (Treatability Test Outline, September 30, 2004). In 2005, DOE-RL and Fluor Hanford convened an independent technical panel to review alternative remediation technologies, including desiccation, at a three-day workshop in Richland, Washington. The panel was composed of experts in vadose-zone transport, infiltration control, hydrology, geochemistry, environmental engineering, and geology. Their backgrounds include employment in academia, government laboratories, industry, and consulting. Their review, presented in this document, is based upon written reports from Hanford, oral presentations from Hanford staff, and each panel members' years of experience in their particular field of expertise. The purpose of this report is to document the panel's evaluation of various treatment alternatives with potential for minimizing contaminant migration in the deep vadose zone at the Department of Energy Hanford Site. The panel was tasked with assessing the most viable and practical approach and making recommendations for testing. The evaluation of vadose-zone treatment alternatives was conducted to be broadly applicable at a variety of locations at Hanford. However

  14. Differences between the macroscopic and tracer level chemistry of rhenium and technetium: contrasting cage isomerisation behaviour of Re(I) and Tc(I) carborane complexes.

    PubMed

    Armstrong, Andrea F; Valliant, John F

    2010-09-21

    Carboranes form stable complexes with the [M(CO)(3)](+) (M = (99m)Tc, Re) core and are viable ligands for the development of targeted radiopharmaceuticals. (99m)Tc-carborane complexes were found to exhibit substantially different 1,2-->1,7 cage isomerisation behaviour than their Re counterparts, challenging the validity of the routine use of rhenium as a surrogate for the development of technetium-99m based molecular imaging agents.

  15. Quantitative single-photon emission computed tomography/computed tomography for technetium pertechnetate thyroid uptake measurement

    PubMed Central

    Lee, Hyunjong; Kim, Ji Hyun; Kang, Yeon-koo; Moon, Jae Hoon; So, Young; Lee, Won Woo

    2016-01-01

    Abstract Objectives: Technetium pertechnetate (99mTcO4) is a radioactive tracer used to assess thyroid function by thyroid uptake system (TUS). However, the TUS often fails to deliver accurate measurements of the percent of thyroid uptake (%thyroid uptake) of 99mTcO4. Here, we investigated the usefulness of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) after injection of 99mTcO4 in detecting thyroid function abnormalities. Materials and methods: We retrospectively reviewed data from 50 patients (male:female = 15:35; age, 46.2 ± 16.3 years; 17 Graves disease, 13 thyroiditis, and 20 euthyroid). All patients underwent 99mTcO4 quantitative SPECT/CT (185 MBq = 5 mCi), which yielded %thyroid uptake and standardized uptake value (SUV). Twenty-one (10 Graves disease and 11 thyroiditis) of the 50 patients also underwent conventional %thyroid uptake measurements using a TUS. Results: Quantitative SPECT/CT parameters (%thyroid uptake, SUVmean, and SUVmax) were the highest in Graves disease, second highest in euthyroid, and lowest in thyroiditis (P < 0.0001, Kruskal–Wallis test). TUS significantly overestimated the %thyroid uptake compared with SPECT/CT (P < 0.0001, paired t test) because other 99mTcO4 sources in addition to thyroid, such as salivary glands and saliva, contributed to the %thyroid uptake result by TUS, whereas %thyroid uptake, SUVmean and SUVmax from the SPECT/CT were associated with the functional status of thyroid. Conclusions: Quantitative SPECT/CT is more accurate than conventional TUS for measuring 99mTcO4 %thyroid uptake. Quantitative measurements using SPECT/CT may facilitate more accurate assessment of thyroid tracer uptake. PMID:27399139

  16. Structural characterization of a bridged 99Tc-Sn-dimethylglyoxime complex: implications for the chemistry of 99mTc-radiopharmaceuticals prepared by the Sn (II) reduction of pertechnetate.

    PubMed Central

    Deutsch, E; Elder, R C; Lange, B A; Vaal, M J; Lay, D G

    1976-01-01

    Reduction of pertechnetate by tin(II) in the presence of dimethylglyoxime is shown, by single crystal x-ray analysis, to yield a technetium-tin-dimethylglyoxime complex in which tin and technetium are intimately connected by a triple bridging arrangement. One bridge consists of a single oxygen atom and it is hypothesized that this bridge arises from the inner sphere reduction of technetium by tin(II), the electrons being transferred through a technetium "yl" oxygen which eventually becomes the bridging atom. Two additional bridges arise from two dimethylglyoxime ligands that function as bidentate nitrogen donors towards Tc and monodentate oxygen donors towards Sn. The tin atom can thus be viewed as providing a three-pronged "cap" on one end of the Tc-dimethylglyoxime complex. The additional coordination sites around Tc are occupied by the two nitrogens of a third dimethylglyoxime ligand, making the Tc seven-coordinate. The additional coordination sites around Sn are occupied by three chloride anions, giving the Sn a fac octahedral coordination environment. From indirect evidence the oxidation states of tin and technetium are tentatively assigned to be IV and V, respectively. Since most 99mTc-radiopharmaceuticals are synthesized by the tin(II) reduction of pertechnetate, it is likely that the Sn-O-Tc linkage described in this work is an important feature of the chemistry of these species. This linkage also provides a ready rationale for the close association of tin and technetium observed in many 99mTc-radiopharmaceuticals. PMID:1069984

  17. Sentinel Lymphadenectomy in Vulvar Cancer Using Near-Infrared Fluorescence From Indocyanine Green Compared With Technetium 99m Nanocolloid.

    PubMed

    Soergel, Philipp; Hertel, Hermann; Nacke, Anna Kaarina; Klapdor, Rüdiger; Derlin, Thorsten; Hillemanns, Peter

    2017-05-01

    Nowadays, sentinel diagnostic is performed using technetium 99m (Tc) nanocolloid as a radioactive marker and sometimes patent blue. In the last years, indocyanine green has been evaluated for sentinel diagnostic in different tumor entities. Indocyanine green is a fluorescent molecule that emits a light signal in the near-infrared band after excitation. Our study aimed to evaluate indocyanine green compared with the criterion-standard Tc-nanocolloid. We included patients with primary, unifocal vulvar cancer of less than 4 cm with clinically node-negative groins in this prospective trial. Sentinel diagnostic was carried out using Tc-nanocolloid, indocyanine green, and patent blue. We examined each groin for light signals from the near-infrared band, for radioactivity, and for blue staining. A sentinel lymph node was defined as a Tc-nanocolloid-positive lymph node. All sentinel lymph nodes and all additional blue or fluorescent lymph nodes were excised and tested and then sent for histologic examination. In all, 27 patients were included in whom we found 91 sentinel lymph nodes in 52 groins. All these lymph nodes were positive for indocyanine green, also giving a sensitivity of 100% (95% confidence interval [CI], 96.0%-100%) compared with Tc-nanocolloid. Eight additional lymph nodes showed indocyanine green fluorescence but no Tc positivity, so that the positive predictive value was 91.9% (95% confidence interval, 84.6%-96.5%). In 1 patient, a false-negative sentinel missed by all 3 modalities was found. Our results show that indocyanine green is a promising approach for inguinal sentinel identification in vulvar cancer with a similar sensitivity as radioactive Tc-nanocolloid and worth to be evaluated in further studies.

  18. Technetium-99m thyroid scan; does it have a diagnostic aid in sub-clinical auto-immune thyroid disease in systemic lupus erythematosus patients?

    PubMed

    Amin, A; Alkemary, A; Abdo, M; Salama, M

    2016-02-01

    Technetium-99m (Tc-99m) thyroid scintigraphy is a well known diagnostic tool that shows the entire gland in a single image. We aimed to evaluate its additive diagnostic value in subclinical autoimmune thyroid disease (S-AITD) in systemic lupus erythematosus (SLE) patients. We investigated 100 systemic lupus erythematosus (SLE) patients without overt thyroid involvement (eight men and 92 women; mean age 40±6.5 years) and 50 age and sex matched controls. All were subjected to thyroid evaluation using anti-thyroglobulin (anti-TG) and anti-thyroid peroxidase (anti-TPO) antibodies; hormones (FT3; FT4 and TSH) and Tc-99m thyroid scintigraphy. 14/100 (14%) and none (0%) were positive for S-AITD in SLE and control groups, respectively (P = 0.0001). They were classified by thyroid scintigraphy and hormonal profile into 2/14 Hashimoto; 10/14 atrophic thyroiditis and 2/14 Graves' disease. Anti-TPO was elevated in 12 SLE cases, while anti-TG was elevated in only 2/14 (P = 0.0001). Thyroid scintigraphy showed statistically significant associations with FT4, TSH and anti-TPO. Tc-99m thyroid scintigraphy may have an additional diagnostic role in S-AITD among SLE patients, with an impact on patient management. This potential needs to be further evaluated in a larger series on a multicenter basis. © The Author(s) 2015.

  19. Identification of Warthin tumor: magnetic resonance imaging versus salivary scintigraphy with technetium-99m pertechnetate.

    PubMed

    Motoori, Ken; Ueda, Takuya; Uchida, Yoshitaka; Chazono, Hideaki; Suzuki, Homare; Ito, Hisao

    2005-01-01

    The aim of this study was to evaluate the accuracy of technetium-99m (Tc-99m) pertechnetate scintigraphy and magnetic resonance (MR) imaging in the diagnosis of Warthin tumor. Sixteen cases of Warthin tumor and 17 cases of non-Warthin tumor were examined by Tc-99m pertechnetate scintigraphy with lemon juice stimulation and MR imaging, including T1-weighted, T2-weighted, short inversion time inversion recovery, diffusion-weighted, and contrast-enhanced dynamic images. We used the receiver operating characteristic (ROC) curve to evaluate diagnostic accuracy. The mean area under the ROC curves of MR imaging in the diagnosis of Warthin tumor (0.97) was higher than that of Tc-99m pertechnetate scintigraphy (0.88). Magnetic resonance imaging is more useful in the evaluation of Warthin tumor than Tc-99m pertechnetate scintigraphy.

  20. Technetium-99 conjugated with methylene diphosphonate inhibits receptor activator of nuclear factor-κB ligand-induced osteoclastogenesis.

    PubMed

    Gong, Wei; Dou, Huan; Liu, Xianqin; Sun, Lingyun; Hou, Yayi

    2012-10-01

    1. In the present study, we investigated the effects of technetium-99 conjugated with methylene diphosphonate ((99)Tc-MDP), an agent used in radionuclide therapy, on receptor activator of nuclear factor-κB ligand (RANKL)-induced osteoclastogenesis and explored the underlying mechanisms. 2. The murine macrophage cell line RAW264.7 and bone marrow-derived-macrophages from C57BL/6 mice (BMM) were used as models for osteoclastogenesis in vitro. The expression of some key factors in RANKL (50 ng/mL)-induced osteoclastogenesis in RAW264.7 cells was investigated by flow cytometry and real-time reverse transcription-polymerase chain reaction (RT-PCR). To detect multinucleated osteoclast formation, RAW264.7 cells were induced with RANKL for 4 days, whereas BMM were induced by 50 ng/mL RANKL and 20 ng/mL macrophage colony-stimulating factor for 7 days, before being stained with tartrate-resistant acid phosphatase. 3. Osteoclastogenesis was evaluated using the osteoclast markers CD51, matrix metalloproteinase (MMP)-9 and cathepsin K. At 0.01 μg/mL, (99)Tc-MDP significantly inhibited RANKL-induced osteoclastogenesis without any cytotoxicity. In addition, (99)Tc-MDP abolished the appearance of multinucleated osteoclasts. 4. Real-time RT-PCR analysis of transcription factor expression revealed that (99)Tc-MDP inhibited the expression of c-Fos and nuclear factor of activated T cells. In addition, (99)Tc-MDP inhibited the expression of the inflammatory factors interleukin (IL)-6, tumour necrosis factor-α and IL-1β. Finally, (99)Tc-MDP inhibited the activation of mitogen-activated protein kinases in RAW264.7 cells following RANKL stimulation. 5. In conclusion, (99)Tc-MDP possesses anti-osteoclastogenic activity against RANKL-induced osteoclast formation. © 2012 The Authors Clinical and Experimental Pharmacology and Physiology © 2012 Wiley Publishing Asia Pty Ltd.

  1. Nuclear waste solutions

    DOEpatents

    Walker, Darrel D.; Ebra, Martha A.

    1987-01-01

    High efficiency removal of technetium values from a nuclear waste stream is achieved by addition to the waste stream of a precipitant contributing tetraphenylphosphonium cation, such that a substantial portion of the technetium values are precipitated as an insoluble pertechnetate salt.

  2. Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain

    PubMed Central

    Erdoğan, Zeynep; Silov, Güler; Özdal, Ayşegül; Turhal, Özgül

    2013-01-01

    Myocardial perfusion imaging (MPI) with technetium-99m sestamibi (Tc-99m MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of Tc-99m MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. PMID:24019679

  3. A tracer dose of technetium-99m-labeled liposomes can estimate the effect of hyperthermia on intratumoral doxil extravasation.

    PubMed

    Kleiter, Miriam M; Yu, Daohai; Mohammadian, Lenore A; Niehaus, Nelsen; Spasojevic, Ivan; Sanders, Linda; Viglianti, Benjamin L; Yarmolenko, Pavel S; Hauck, Marlene; Petry, Neil A; Wong, Terence Z; Dewhirst, Mark W; Thrall, Donald E

    2006-11-15

    A noninvasive method to monitor intratumoral Doxil delivery in individual patients during targeted tumor therapy is important to predict treatment response. The purpose of this study was to determine if a small tracer dose of technetium-99m (99mTc)-labeled liposomes could be used to quantify the effect of local hyperthermia on intratumoral Doxil extravasation. Experiments were carried out in a rat fibrosarcoma model with transplanted thigh tumors. Liposomes of approximately same size and composition as Doxil were radiolabeled using [technetium-99m (99mTc)]exametazime. Eight treatment groups received either Doxil, a tracer dose or a large dose of 99mTc-labeled liposomes, or a combination of tracer and Doxil, with or without hyperthermia. This design was chosen to assure that coadministration of both liposomal formulations did not influence their intratumoral distribution. Hyperthermia was done for 45 minutes. Scintigraphic images were obtained at 5 and 18 hours. At 18 hours, tumors were removed and gamma counts as well as doxorubicin concentrations were measured. Intratumoral extravasation of the 99mTc-labeled tracer could be imaged scintigraphically under normothermic and hyperthermic conditions. The thermal enhancement ratio was slightly higher for radiolabeled liposomes than for doxorubicin concentration. However, there was a significant positive correlation of intratumoral doxorubicin concentration and intratumoral uptake of the radiolabeled tracer (expressed as percentage of the injected dose per gram of tissue). Coadministration of radiolabeled liposomes did not negatively influence the amount of drug delivered with Doxil. The use of a radiolabeled tracer has potential value to monitor drug delivery and estimate the effect of an intervention aimed to increase liposomal accumulation, such as local hyperthermia.

  4. Rhenium Solubility in Borosilicate Nuclear Waste Glass: Implications for the Processing and Immobilization of Technetium-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCloy, John S.; Riley, Brian J.; Goel, Ashutosh

    2012-10-26

    The immobilization of 99Tc in a suitable host matrix has proved to be an arduous task for the researchers in nuclear waste community around the world. At the Hanford site in Washington State, the total amount of 99Tc in low-activity waste (LAW) is ~1300 kg and the current strategy is to immobilize the 99Tc in borosilicate glass with vitrification. In this context, the present article reports on the solubility/retention of rhenium, a nonradioactive surrogate for 99Tc, in a LAW borosilicate glass. Due to the radioactive nature of technetium, rhenium was chosen as a simulant because of the similarity between theirmore » ionic radii and other chemical aspects. The glasses containing Re (0 – 10,000 ppm by mass) were synthesized in vacuum-sealed quartz ampoules in order to minimize the loss of Re by volatilization during melting at 1000 °C. The rhenium was found to predominantly exist as Re (VII) in all the glasses as observed by X-ray absorption near-edge structure (XANES). The solubility of Re in borosilicate glasses was determined to be ~3000 ppm (by mass) with inductively coupled plasma-optical emission spectroscopy (ICP-OES). At higher rhenium concentrations, some additional material was retained in the glasses in the form of crystalline inclusions that were detected by X-ray diffraction (XRD) and laser ablation-ICP mass spectrometry (LA-ICP-MS). The implications of these results on the immobilization of 99Tc from radioactive wastes in borosilicate glasses have been discussed.« less

  5. A solvent-extraction module for cyclotron production of high-purity technetium-99m.

    PubMed

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Uccelli, Licia; Pasquali, Micòl; Duatti, Adriano; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Esposito, Juan

    2016-12-01

    The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99m TcO 4 - , in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na 99m TcO 4 , purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99m Tc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotrons. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Examination of Technetium Transport Through Soils Under Contrasting Redox Conditions: Batch and Column Work

    NASA Astrophysics Data System (ADS)

    Dozier, R.; Montgomery, D.; Wylie, E. M.; Dogan, M.; Moysey, S. M.; Powell, B. A.; Martinez, N. E.

    2015-12-01

    Experiments were performed under various reducing conditions to evaluate the transport behavior of technetium-99 (99Tc) in the presence of sandy clay loam soil from the Savannah River Site (SRS) and goethite, magnetite, and iron sulfide, which were selected for their increasing reducing potential. The experiments were conducted to investigate how redox reaction equilibria and rates affect the overall mobility of 99Tc as it transitions between the mobile Tc(VII) and immobile Tc(IV). Under oxygen-rich conditions, batch sorption isotherms measured for TcO4- across the concentration range 0.5 to 50 μg/L were linear with distribution coefficients (Kd) of 0.78 mL/g or lower, with decreasing sorption for goethite, magnetite, and iron sulfide, respectively. Addition of Na2S resulted in a marked increase in apparent 99Tc sorption to the solid phase, with Kd of 43 mL/g, 35 mL/g, and 29 mL/g, following the same mineral trend as previously. The increased Kd values are possibly due to reduction of Tc(VII) to Tc(IV), resulting in the formation of TcO2(s). SRS soil batch sorption isotherms measured for TcO4- across the same concentration range were also linear, with Kd of 0.7 mL/g for unadjusted pH, 5.1 mL/g for pH of around 6, and 6.7 mL/g for pH of around 4. Kinetic batch sorption tests showed less than 10% 99Tc sorption in an oxidizing environment and greater than 95% sorption in a reducing environment, with both reactions occurring on the order of minutes. In contrast, desorption experiments initiated by transferring the samples from a reducing environment (0.1% H2(g)/99.9% N2(g)) to atmospheric conditions resulted in a slow desorption step on the order of days. Column experiments conducted with the SRS sands indicate a retardation factor of 1.17 for 99Tc under oxygen rich conditions. Additional column experiments are being conducted to evaluate 99Tc transport dependencies on transitions between oxygen rich and poor conditions.

  7. Technetium incorporation into goethite (α-FeOOH): An atomic-scale investigation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Frances N.; Taylor, Christopher D.; Um, Wooyong

    2015-11-17

    During the processing of low-activity radioactive waste to generate solid waste forms (e.g., glass), technetium-99 (Tc) is of concern because of its volatility. A variety of materials are under consideration to capture Tc from waste streams, including the iron oxyhydroxide, goethite (α-FeOOH), which was experimentally shown to sequester Tc(IV). This material could ultimately be incorporated into glass or other low-temperature waste form matrices. However, questions remain regarding the incorporation mechanism for Tc(IV) in goethite, which has implications for predicting the long-term stability of Tc in waste forms under changing conditions. Here, quantum-mechanical calculations were used to evaluate the energy ofmore » five different charge-compensated Tc(IV) incorporation scenarios in goethite. The two most stable incorporation mechanisms involve direct substitution of Tc(IV) onto Fe(III) lattice sites and charge balancing either by removing one nearby H+ (i.e., within 5 Å), or by creating an Fe(III) vacancy when substituting 3 Tc(IV) for 4 Fe(III), with the former being preferred over the latter relative to gas-phase ions. When corrections for hydrated references phases are applied, the Fe(III)-vacancy mechanism becomes more energetically competitive. Calculated incorporation energies and optimized bond-lengths are presented. Proton movement is observed to satisfy under-coordinated bonds surrounding vacancies in the goethite structure.« less

  8. Guava extract (Psidium guajava) alters the labelling of blood constituents with technetium-99m.

    PubMed

    Abreu, P R C; Almeida, M C; Bernardo, R M; Bernardo, L C; Brito, L C; Garcia, E A C; Fonseca, A S; Bernardo-Filho, M

    2006-06-01

    Psidium guajava (guava) leaf is a phytotherapic used in folk medicine to treat gastrointestinal and respiratory disturbances and is used as anti-inflammatory medicine. In nuclear medicine, blood constituents (BC) are labelled with technetium-99m ((99m)Tc) and used to image procedures. However, data have demonstrated that synthetic or natural drugs could modify the labelling of BC with (99m)Tc. The aim of this work was to evaluate the effects of aqueous extract of guava leaves on the labelling of BC with (99m)Tc. Blood samples of Wistar rats were incubated with different concentrations of guava extract and labelled with (99m)Tc after the percentage of incorporated radioactivity (%ATI) in BC was determined. The results suggest that aqueous guava extract could present antioxidant action and/or alters the membrane structures involved in ion transport into cells, thus decreasing the radiolabelling of BC with (99m)Tc. The data showed significant (P<0.05) alteration of ATI in BC from blood incubated with guava extract.

  9. Guava extract (Psidium guajava) alters the labelling of blood constituents with technetium-99m*

    PubMed Central

    Abreu, P.R.C.; Almeida, M.C.; Bernardo, R.M.; Bernardo, L.C.; Brito, L.C.; Garcia, E.A.C.; Fonseca, A.S.; Bernardo-Filho, M.

    2006-01-01

    Psidium guajava (guava) leaf is a phytotherapic used in folk medicine to treat gastrointestinal and respiratory disturbances and is used as anti-inflammatory medicine. In nuclear medicine, blood constituents (BC) are labelled with technetium-99m (99mTc) and used to image procedures. However, data have demonstrated that synthetic or natural drugs could modify the labelling of BC with 99mTc. The aim of this work was to evaluate the effects of aqueous extract of guava leaves on the labelling of BC with 99mTc. Blood samples of Wistar rats were incubated with different concentrations of guava extract and labelled with 99mTc after the percentage of incorporated radioactivity (%ATI) in BC was determined. The results suggest that aqueous guava extract could present antioxidant action and/or alters the membrane structures involved in ion transport into cells, thus decreasing the radiolabelling of BC with 99mTc. The data showed significant (P<0.05) alteration of ATI in BC from blood incubated with guava extract. PMID:16691636

  10. Behavior of technetium-99 in soils and plants. Final report, April 1, 1974--December 31, 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gast, R.G.; Landa, E.R.; Thorvig, L.J.

    Studies described in this report were aimed at establishing the magnitude and mechanisms of /sup 99/Tc sorption by soils and uptake by plants. Results show that /sup 99/Tc was sorbed from solution over a period to two to five weeks by 8 of 11 soils studies. The slow rate of sorption, the lack of sorption by low organic matter soils, the elimination of sorption following sterilization and increased sorption following addition of dextrose all point to a microbial role in the sorption process. However, it has not been established whether this is a direct or indirect role nor is itmore » possible to clearly predict the conditions under which sorption will occur. Results of plant uptake studies show that /sup 99/Tc can be taken up and translocated into the photosynthetic tissue of higher plants with concentrations in seeds being much less than in vegetative tissue. Technetium-99 was also shown to be toxic to plants at low concentrations and evidence suggests that this is a chemically rather than radiologically induced toxicity. However, this remains to be completely resolved as well as whether there is a threshold level of /sup 99/Tc required before toxicity occurs. Studies of short-term, dynamic, aerobic systems indicated that /sup 99/Tc moves through the soil as a relatively large anion exhibiting characteristic miscible displacement with some asymmetric tailing. /sup 99/Tc exhibits greater retention that C1/sup -/, which may be attributed statistically to weak complexion by organic matter. It is unlikely that this retention phenomenon is related to the static sorption activity reported in the first part of this study.« less

  11. Computational Investigation of Technetium(IV) Incorporation into Inverse Spinels: Magnetite (Fe 3 O 4 ) and Trevorite (NiFe 2 O 4 )

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Smith, Frances N.; Um, Wooyong; Taylor, Christopher D.

    2016-05-17

    Iron oxides and oxyhydroxides play an important role in minimizing the mobility of redox-sensitive elements in engineered and natural environments. For the radionuclide technetium-99 (Tc), these phases hold promise as primary hosts for increasing Tc loading into glass waste form matrices, or as secondary sinks during the long-term storage of nuclear materials. Recent experiments show that the inverse spinel, magnetite [Fe(II)Fe(III)2O4], can incorporate Tc(IV) into its octahedral sub-lattice, and in that same class of materials, trevorite [Ni(II)Fe(III)2O4] is also being investigated for its ability to host Tc(IV). However, questions remain regarding the most energetically favorable charge-compensation mechanism for Tc(IV) incorporationmore » in each structure, which will affect Tc behavior under changing waste processing or storage conditions. Here, quantum-mechanical methods were used to evaluate incorporation energies and optimized lattice bonding environments for three different, charge-balanced Tc(IV) incorporation mechanisms in magnetite and trevorite. In both cases, the removal of two octahedral Fe(II) or Ni(II) ions upon the addition of Tc(IV) to an octahedral site is the most stable mechanism, relative to the creation of octahedral Fe(III) defects or increasing octahedral Fe(II) content. Following hydration-energy corrections, Tc(IV) incorporation into magnetite is energetically favorable while an energy barrier exists for trevorite.« less

  12. Value of positive myocardial technetium-99m-pyrophosphate scintigraphy in the noninvasive diagnosis of cardiac amyloidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wizenberg, T.A.; Muz, J.; Sohn, Y.H.

    1982-04-01

    Ten consecutive patients with tissue-proven amyloidosis, seven of whom presented with congestive heart failure, were found to exhibit intense diffuse uptake of technetium-99m-pyrophosphate (Tc-99m-PYP) on cardiac radionuclide imaging. The patients exhibited echocardiographic and systolic time interval abnormalities suggesting combined restrictive and congestive cardiomyopathic changes. On M-mode echocardiograms, there was symmetrically increased thickness of the interventricular septum and left ventricular (LV) posterior wall in diastole (10 of 10), decreased fractional shortening of the LV minor axis diameter in systole (eight of nine), and decreased percent thickening of the LV minor axis diameter in systole (eight of nine) and LV posterior wallmore » (10 of 10) in systole. Three patients demonstrated enlarged LV end-diastolic diameter. All 10 patients had abnormal PEP/LVET and eight had shortened LVETI. When combined with noninvasive tests of LV performance, positive myocardial pyrophosphate (PYP) scanning provides a new and useful adjunct in the diagnosis of amyloid heart disease.« less

  13. Residence time effects on technetium reduction in slag-based cementitious materials.

    PubMed

    Arai, Yuji; Powell, Brian A; Kaplan, D I

    2018-01-15

    A long-term disposal of technetium-99 ( 99 Tc) has been considered in a type of cementitious formulation, slag-based grout, at the U.S. Department of Energy, Savannah River Site, Aiken SC, U.S.A. Blast furnace slag, which contains S and Fe electron donors, has been used in a mixture with fly ash, and Portland cement to immobilize 99 Tc(VII)O 4 - (aq) in low level radioactive waste via reductive precipitation reaction. However the long-term stability of Tc(IV) species is not clearly understood as oxygen gradually diffuses into the solid structure. In this study, aging effects of Tc speciation were investigated as a function of depth (<2.5cm) in slag-based grout using X-ray absorption spectroscopy. All of Fe(II) in solids was oxidized to Fe(III) after 117d. However, elemental S, sulfide, and sulfoxide persists at the 0-8mm depths even after 485d, suggesting the presence of a reduced zone below the surface few millimeters. Pertechnetate was successfully reduced to Tc(IV) after 29d. Distorted hydrolyzed Tc(IV) octahedral molecules were partially sulfidized and or polymerized at all depths (0-8mm) and were stable in 485d aged sample. The results of this study suggest that variable S species contribute to stabilize the partially sulfidized Tc(IV) species in aged slag-based grout. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Rhenium and technetium tricarbonyl, {M(CO)3} (+) (M = Tc, Re), binding to mammalian metallothioneins: new insights into chemical and radiopharmaceutical implications.

    PubMed

    Lecina, Joan; Palacios, Òscar; Atrian, Sílvia; Capdevila, Mercè; Suades, Joan

    2015-04-01

    This paper deals with the binding of the four mammalian metallothioneins (MTs) to the organometallic metal fragment {fac-M(CO)3}(+) (M = (99)Tc, Re), which is highly promising for the preparation of second-generation radiopharmaceuticals. The study of the transmetallation reaction between zinc and rhenium in Zn7-MT1 by means of UV-vis and CD spectroscopy demonstrated the incorporation of the {fac-Re(CO)3}(+) fragment to the MTs. This reaction should be performed at 70 °C to accelerate the reaction rate, a result that is consistent with the reported reactivity of the rhenium fragment. ESI-TOF MS demonstrated the formation of mixed-metal species as Zn6,{Re(CO)3}-MT, Zn6,{Re(CO)3}2-MT, and Zn5,{Re(CO)3}3-MT, as well as the different reactivity of the four MT isoforms. Hence, Zn-MT3 showed the highest reactivity, in agreement with its high Cu-thionein character, whereas Zn-MT2 exhibited the lowest reactivity, in line with its high Zn-thionein character. The reactivity of the Zn-loaded forms of MT1 and MT4 is intermediate between those of MT3 and MT2. The study of the binding of the {fac-(99)Tc(CO)3}(+) fragment to MTs showed a significant and very interesting different reactivity in relation to rhenium. The transmetallation reaction is much more effective with technetium than with rhenium and significant amounts of mixed Zn x ,{(99)Tc(CO)3} y -MT species were formed with the four MT isoforms whereas only MT3 rendered similar amounts of rhenium derivatives. The results obtained in this study support the possible use of technetium for labelling mammalian metallothioneins and also for possible radiopharmaceutical applications.

  15. [Improvement in nuclear medicine diagnosis of kidney function using 99m technetium mercaptoacetyltriglycine (MAG3)].

    PubMed

    Erpenbach, K; Ebert, A; Wieler, H

    1991-03-01

    Renal scintigraphy and clearance measurement are indispensable in nephro-urologic disorders. A continuous series of 103 sequential scintigraphies and clearance measurements were performed with the new technetium-labelled agent MAG3 (Gamma-kamera, Phillips Tomo Diagnost) and 131I-orthohippuric acid (OIH) using the Oberhausen method (Nucleopan, Siemens). The time-activity curves obtained with the two radionuclides agreed exactly. Reaching a tubular excretion rate of nearly 90%, the clearance of MAG3 differed by no more than 6% from the OIH clearance in 95% of the cases. The factor between clearances of the two radionuclides was determined by means of a commercially available software according to the Oberhausen method and amounted to 0.59 +/- 0.09. The favorable physical properties and high activity of MAG3 permit exact examination of tubular function and better assessment of renal morphology than hippuran-labelled radionuclides. The low radiation dose combined with a better spatial resolution, especially, the constant availability in a nuclear medicine department should give the preference to MAG3.

  16. Evolution of technetium-99m-HMPAO SPECT and brain mapping in a patient presenting with echolalia and palilalia.

    PubMed

    Dierckx, R A; Saerens, J; De Deyn, P P; Verslegers, W; Marien, P; Vandevivere, J

    1991-08-01

    A 78-yr-old woman presented with transient echolalia and palilalia. She had suffered from Parkinson's disease for 2 yr. Routine laboratory examination showed hypotonic hyponatremia, but was otherwise unremarkable. Brain mapping revealed a bifrontal delta focus, more pronounced on the right. Single photon emission computed tomography (SPECT) of the brain with technetium-99m labeled d,l hexamethylpropylene-amine oxime (99mTc-HMPAO), performed during the acute episode showed relative frontoparietal hypoactivity. Brain mapping performed after disappearance of the echolalia and palilalia, which persisted only for 1 day, was normal. By contrast, SPECT findings persisted for more than 3 wk. Features of particular interest in the presented patient are the extensive defects seen on brain SPECT despite the absence of morphologic lesions, the congruent electrophysiologic changes and their temporal relationship with the clinical evolution.

  17. Detection of occult pericardial hemorrhage early after open-heart surgery using technetium-99m red blood cell radionuclide ventriculography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bateman, T.M.; Czer, L.S.; Gray, R.J.

    1984-11-01

    Pericardial or mediastinal hemorrhage requiring reoperation occurs in 2% to 5% of patients, usually early (0 to 48 hours), after open-heart surgery. This hemorrhage may be occult, and resulting cardiac tamponade may easily be misinterpreted as ventricular dysfunction, common early postoperatively. In such cases, appropriate and timely intervention may not occur. Of 50 patients evaluated by technetium-99m red blood cell gated equilibrium radionuclide ventriculography (RNV) because of early postoperative cardiogenic shock of uncertain etiology, 17 had unique scintigraphic images suggestive of intrathoracic hemorrhage. Of these 17, 5 had a generalized halo of abnormal radioactivity surrounding small hyperdynamic right and leftmore » ventricles, 11 had localized regions of intense blood pool activity outside the cardiac chambers (two with compression of single chambers), and one demonstrated marked radionuclide activity in the right hemithorax (2000 ml of blood at reoperation). Twelve patients had exploratory reoperation for control of hemorrhage as a direct result of the scintigraphic findings, three were successfully treated with fresh frozen plasma and platelet infusions along with medical interventions to optimize cardiac performance, and two patients died in cardiogenic shock (presumed tamponade) without reoperation. In the 12 reoperated patients, all were confirmed to have active pericardial bleeding. Scintigraphic localization of abnormal blood pools within the pericardium corresponded to the sites at which active bleeding was witnessed at reoperation. The abnormal bleeding was etiologically related to the tamponade state, with marked improvement in hemodynamics after reoperation. Nine additional patients were reoperated for presumed tamponade after RNV revealed an exaggerated halo of photon deficiency surrounding the cardiac chambers.« less

  18. Technetium uptake predicts remission and relapse in Grave's disease patients on antithyroid drugs for at least 1 year in South Indian subjects

    PubMed Central

    Singhal, Neha; Praveen, V. P.; Bhavani, Nisha; Menon, Arun S.; Menon, Usha; Abraham, Nithya; Kumar, Harish; JayKumar, R. V.; Nair, Vasantha; Sundaram, Shanmugha; Sundaram, Padma

    2016-01-01

    Context: Most of the information on remission related factors in Grave's disease are derived from Western literature. It is likely that there may be additional prognostic factors and differences in the postdrug treatment course of Grave's disease in India. Aim: To study factors which predict remission/relapse in Grave's disease patients from South India. Also to establish if technetium (Tc) uptake has a role in predicting remission. Subjects and Methods: Records of 174 patients with clinical, biochemical, and scintigraphic criteria consistent with Grave's disease, seen in our Institution between January 2006 and 2014 were analyzed. Patient factors, drug-related factors, Tc-99m uptake and other clinical factors were compared between the remission and nonremission groups. Statistical Analysis Used: Mann–Whitney U-test and Chi-square tests were used when appropriate to compare the groups. Results: Fifty-seven (32.7%) patients attained remission after at least 1 year of thionamide therapy. Of these, 11 (19.2%) patients relapsed within 1 year. Age, gender, goiter, and presence of extrathyroidal manifestations were not associated with remission. Higher values of Tc uptake were positively associated with remission (P- 0.02). Time to achievement of normal thyroid function and composite dose: Time scores were significantly associated with remission (P - 0.05 and P - 0.01, respectively). Patients with lower FT4 at presentation had a higher chance of remission (P - 0.01). The relapse rates were lower than previously reported in the literature. A higher Tc uptake was found to be significantly associated with relapse also (P - 0.009). Conclusion: The prognostic factors associated with remission in Graves's disease in this South Indian study are not the same as that reported in Western literature. Tc scintigraphy may have an additional role in identifying people who are likely to undergo remission and thus predict the outcome of Grave's disease. PMID:27042408

  19. Technetium uptake predicts remission and relapse in Grave's disease patients on antithyroid drugs for at least 1 year in South Indian subjects.

    PubMed

    Singhal, Neha; Praveen, V P; Bhavani, Nisha; Menon, Arun S; Menon, Usha; Abraham, Nithya; Kumar, Harish; JayKumar, R V; Nair, Vasantha; Sundaram, Shanmugha; Sundaram, Padma

    2016-01-01

    Most of the information on remission related factors in Grave's disease are derived from Western literature. It is likely that there may be additional prognostic factors and differences in the postdrug treatment course of Grave's disease in India. To study factors which predict remission/relapse in Grave's disease patients from South India. Also to establish if technetium (Tc) uptake has a role in predicting remission. Records of 174 patients with clinical, biochemical, and scintigraphic criteria consistent with Grave's disease, seen in our Institution between January 2006 and 2014 were analyzed. Patient factors, drug-related factors, Tc-99m uptake and other clinical factors were compared between the remission and nonremission groups. Mann-Whitney U-test and Chi-square tests were used when appropriate to compare the groups. Fifty-seven (32.7%) patients attained remission after at least 1 year of thionamide therapy. Of these, 11 (19.2%) patients relapsed within 1 year. Age, gender, goiter, and presence of extrathyroidal manifestations were not associated with remission. Higher values of Tc uptake were positively associated with remission (P- 0.02). Time to achievement of normal thyroid function and composite dose: Time scores were significantly associated with remission (P - 0.05 and P - 0.01, respectively). Patients with lower FT4 at presentation had a higher chance of remission (P - 0.01). The relapse rates were lower than previously reported in the literature. A higher Tc uptake was found to be significantly associated with relapse also (P - 0.009). The prognostic factors associated with remission in Graves's disease in this South Indian study are not the same as that reported in Western literature. Tc scintigraphy may have an additional role in identifying people who are likely to undergo remission and thus predict the outcome of Grave's disease.

  20. Rhenium and technetium tricarbonyl complexes of 1,4-Substituted pyridyl-1,2,3-triazole bidentate 'click' ligands conjugated to a targeting RGD peptide.

    PubMed

    Connell, Timothy U; Hayne, David J; Ackermann, Uwe; Tochon-Danguy, Henri J; White, Jonathan M; Donnelly, Paul S

    2014-04-01

    New 1,4-substituted pyridyl-1,2,3-triazole ligands with pendent phenyl isothiocyanate functional groups linked to the heterocycle through a short methylene or longer polyethylene glycol spacers were prepared and conjugated to a peptide containing the arginine-glycine-aspartic acid peptide motif. Rhenium and technetium carbonyl complexes, [M(CO)3 L(x) (py)](+) (where M = Re(I) or (99m) Tc(I) ; L(x)  = 1,4-substituted pyridyl-1,2,3-triazole ligands and py = pyridine) were prepared. One rhenium complex has been characterized by X-ray crystallography, and the luminescent properties of [M(CO)3 L(x) (py)](+) are reported. Copyright © 2013 John Wiley & Sons, Ltd.

  1. Comparison of indium-labeled-leukocyte imaging with sequential technetium-gallium scanning in the diagnosis of low-grade musculoskeletal sepsis. A prospective study

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merkel, K.D.; Brown, M.L.; Dewanjee, M.K.

    We prospectively compared sequential technetium-gallium imaging with indium-labeled-leukocyte imaging in fifty patients with suspected low-grade musculoskeletal sepsis. Adequate images and follow-up examinations were obtained for forty-two patients. The presence or absence of low-grade sepsis was confirmed by histological and bacteriological examinations of tissue specimens taken at surgery in thirty of the forty-two patients. In these thirty patients, the sensitivity of sequential Tc-Ga imaging was 48 per cent, the specificity was 86 per cent, and the accuracy was 57 per cent, whereas the sensitivity of the indium-labeled-leukocyte technique was 83 per cent, the specificity was 86 per cent, and the accuracymore » was 83 per cent. When the additional twelve patients for whom surgery was deemed unnecessary were considered, the sensitivity of sequential Tc-Ga imaging was 50 per cent, the specificity was 78 per cent, and the accuracy was 62 per cent, as compared with a sensitivity of 83 per cent, a specificity of 94 per cent, and an accuracy of 88 per cent with the indium-labeled-leukocyte method. In patients with a prosthesis the indium-labeled-leukocyte image was 94 per cent accurate, compared with 75 per cent accuracy for sequential Tc-Ga imaging. Statistical analysis of these data demonstrated that the indium-labeled-leukocyte technique was superior to sequential Tc-Ga imaging in detecting areas of low-grade musculoskeletal sepsis.« less

  2. A prospective evaluation of preoperative localization by technetium-99m sestamibi scintigraphy and ultrasonography in primary hyperparathyroidism.

    PubMed

    Lo, Chung-Yau; Lang, Brian H; Chan, W F; Kung, Annie W C; Lam, Karen S L

    2007-02-01

    Ultrasonography (USG) and technetium-99m sestamibi (MIBI) scintigraphy are commonly used imaging modalities in the era of minimally invasive parathyroidectomy (MIP) for primary hyperparathyroidism (pHPT). However, their relative importance and actual contribution to MIP have not been prospectively assessed. A total of 100 consecutive pHPT patients planning for MIP were recruited. Both USG and MIBI findings were correlated with intraoperative findings and postoperative outcome. Clinicopathologic factors were examined for potential association with a correct localizing result. Thirty men and 70 women (age range 13 to 93 years [median 55.5]) were included in the study. The final pathology included 98 patients with solitary adenoma and 2 patients with multiglandular disease. The sensitivities, accuracies, and positive predicted values for USG and MIBI alone were 57% vs 89%, 56% vs 85%, and 97% vs 94%, respectively. Correctly localized adenomas were significantly heavier than incorrectly localized ones. MIBI is preferred over USG in pHPT patients planning for MIP. Weight of adenoma appeared to be the only clinicopathologic factor determining localization accuracy.

  3. Technetium Incorporation in Glass for the Hanford Tank Waste Treatment and Immobilization Plant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kruger, Albert A.; Kim, Dong Sang

    2015-01-14

    A priority of the United States Department of Energy (U.S. DOE) is to dispose of nuclear wastes accumulated in 177 underground tanks at the Hanford Nuclear Reservation in eastern Washington State. These nuclear wastes date from the Manhattan Project of World War II and from plutonium production during the Cold War. The DOE plans to separate high-level radioactive wastes from low activity wastes and to treat each of the waste streams by vitrification (immobilization of the nuclides in glass) for disposal. The immobilized low-activity waste will be disposed of here at Hanford and the immobilized high-level waste at the nationalmore » geologic repository. Included in the inventory of highly radioactive wastes is large volumes of 99Tc (~9 × 10E2 TBq or ~2.5 × 104 Ci or ~1500 kg). A problem facing safe disposal of Tc-bearing wastes is the processing of waste feed into in a chemically durable waste form. Technetium incorporates poorly into silicate glass in traditional glass melting. It readily evaporates during melting of glass feeds and out of the molten glass, leading to a spectrum of high-to-low retention (ca. 20 to 80%) in the cooled glass product. DOE-ORP currently has a program at Pacific Northwest National Laboratory (PNNL), in the Department of Materials Science and Engineering at Rutgers University and in the School of Mechanical and Materials Engineering at Washington State University that seeks to understand aspects of Tc retention by means of studying Tc partitioning, molten salt formation, volatilization pathways, and cold cap chemistry. Another problem involves the stability of Tc in glass in both the national geologic repository and on-site disposal after it has been immobilized. The major environmental concern with 99Tc is its high mobility in addition to a long half-life (2.1×105 yrs). The pertechnetate ion (TcO4-) is highly soluble in water and does not adsorb well onto the surface of minerals and so migrates nearly at the same velocity as

  4. 99mTechnetium and methylene blue guided pulmonary nodules resections: preliminary British experience.

    PubMed

    Nardini, Marco; Bilancia, Rocco; Paul, Ian; Jayakumar, Shruti; Papoulidis, Pavlos; ElSaegh, Mohamed; Hartley, Richard; Richardson, Mark; Misra, Pankash; Migliore, Marcello; Dunning, Joel

    2018-02-01

    Subcentimetre pulmonary nodules can be challenging to locate either during video-assisted thoracoscopic surgery (VATS) or by open techniques. In an era of increasing computed tomography scan availability the number of nodules that are identified that are suspicious for malignancy is rising, and thoracic surgeons require a reliable method to locate these nodules intraoperatively. Our aim was to evaluate, for the first time in the UK, resection of pulmonary nodules using radioactive dye labelling. Local research ethics approval was obtained and the study was submitted to the Integrated Research Application System (IRAS). All data were prospectively collected in our dedicated thoracic surgical database and analyzed at the conclusion of the study. This represents a consecutive series of patients, from January 2016 and until April 2017, who underwent this procedure at our institution: James Cook University Hospital, Middlesbrough, United Kingdom. The primary outcome measured was successful resection rate of the target nodules. Twenty-three patients underwent radiolabeled excision of pulmonary nodules, their average age was 61 years (range, 28-79 years), 13 women and 10 men. The average maximum diameter of the nodule was 8 mm (range, 3-16 mm). All patients underwent successful excision of the target lesion (success rate 100%). One patient (4.3%) sustained pneumothorax following the CT-guided injection of the radio-labelled dye and this required chest drainage prior to general anesthesia. We conclude that technetium guided pulmonary nodule resection is a very reliable method for localization and resection of subcentimetre nodules which may be otherwise be difficult to identify.

  5. 99mTechnetium and methylene blue guided pulmonary nodules resections: preliminary British experience

    PubMed Central

    Bilancia, Rocco; Paul, Ian; Jayakumar, Shruti; Papoulidis, Pavlos; ElSaegh, Mohamed; Hartley, Richard; Richardson, Mark; Misra, Pankash; Migliore, Marcello; Dunning, Joel

    2018-01-01

    Background Subcentimetre pulmonary nodules can be challenging to locate either during video-assisted thoracoscopic surgery (VATS) or by open techniques. In an era of increasing computed tomography scan availability the number of nodules that are identified that are suspicious for malignancy is rising, and thoracic surgeons require a reliable method to locate these nodules intraoperatively. Methods Our aim was to evaluate, for the first time in the UK, resection of pulmonary nodules using radioactive dye labelling. Local research ethics approval was obtained and the study was submitted to the Integrated Research Application System (IRAS). All data were prospectively collected in our dedicated thoracic surgical database and analyzed at the conclusion of the study. This represents a consecutive series of patients, from January 2016 and until April 2017, who underwent this procedure at our institution: James Cook University Hospital, Middlesbrough, United Kingdom. The primary outcome measured was successful resection rate of the target nodules. Results Twenty-three patients underwent radiolabeled excision of pulmonary nodules, their average age was 61 years (range, 28–79 years), 13 women and 10 men. The average maximum diameter of the nodule was 8 mm (range, 3–16 mm). All patients underwent successful excision of the target lesion (success rate 100%). One patient (4.3%) sustained pneumothorax following the CT-guided injection of the radio-labelled dye and this required chest drainage prior to general anesthesia. Conclusions We conclude that technetium guided pulmonary nodule resection is a very reliable method for localization and resection of subcentimetre nodules which may be otherwise be difficult to identify. PMID:29607175

  6. [Evaluation of green indocyanine interest compared to Technetium in sentinel lymph node detection in breast cancer].

    PubMed

    Guenane, Y; Gorj, M; Nguyen, V; Revol, M; Mazouz-Dorval, S

    2016-12-01

    Axillary sentinel lymph node (SN) biopsy by using indocyanine green (ICG) fluorescence for breast cancer is a recent technique. However, compared to Technetium-99m (Tc), which is the reference technique, its efficiency has received little testing. Between December 2013 and January 2014, 40 patients with node-negative breast cancer underwent SN biopsy by injecting sub areolar Tc in preoperative stage and injecting sub areolar ICG in intraoperative stage. SN were previously identified and resected by using ICG coupled with infrared camera. After resection of fluorescent SN, we check its radioactivity with a gamma probe (isotopic method). In case of residual radioactive labeling in the axillary crease, we remove the remaining SN. We have retrospectively analyzed the SN detection concordance rates of these two methods. In total we resected 53 SN, among which 48 (90.6%) were indocyanine green positive and 53 (100%) Tc positive. The remaining 5 SN were all ICG negative and Tc positive. Using ICG has not caused any side effect. SN detection for breast cancer by using ICG fluorescence is a promising, reliable technique which nonetheless requires a degree of expertise before reaching similar results as the Tc technique. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  7. 99mTechnetium-based Prostate-specific Membrane Antigen-radioguided Surgery in Recurrent Prostate Cancer.

    PubMed

    Maurer, Tobias; Robu, Stephanie; Schottelius, Margret; Schwamborn, Kristina; Rauscher, Isabel; van den Berg, Nynke S; van Leeuwen, Fijs W B; Haller, Bernhard; Horn, Thomas; Heck, Matthias M; Gschwend, Jürgen E; Schwaiger, Markus; Wester, Hans-Jürgen; Eiber, Matthias

    2018-04-03

    Prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) can visualize metastatic lesions in recurrent prostate cancer (PC). However, reliable identification of small and/or atypically localized lesions during salvage surgery procedures is challenging. To describe the technique, feasibility, and short-term outcomes of 99m Technetium ( 99m Tc)-based PSMA-radioguided surgery ( 99m Tc-PSMA-RGS) for removal of recurrent PC lesions. Thirty-one consecutive patients with evidence of recurrent PC on 68 Ga-PSMA N,N'-bis[2-hydroxy-5-(carboxyethyl)benzyl] ethylenediamine-N,N'-diacetic acid ( 68 Ga-PSMA-11) PET after radical prostatectomy undergoing 99m Tc-PSMA-RGS were retrospectively analyzed. Salvage surgery with intraoperative radioguidance using a gamma probe was performed after intravenous application of 99m Tc-PSMA investigation and surgery (mean activity 571 MBq, mean time to surgery 19.7h). Radioactive rating (positive vs negative) of resected tissue was compared with the findings of postoperative histopathological analysis. Best prostate-specific antigen (PSA) response without additional treatment was determined after 8-16 wk postoperatively. Biochemical recurrence- and treatment-free survival was evaluated. In total, 132 tissue specimens were removed, of which 58 showed metastatic involvement on histological analysis. On a specimen basis, radioactive rating yielded a sensitivity of 83.6% (confidence interval [CI]: 70.9-91.5%), a specificity of 100%, and an accuracy of 93.0% (CI: 85.5-96.7%). With 99m Tc-PSMA-RGS, all lesions visualized on preoperative 68 Ga-PSMA-11 PET could be removed. Moreover, 99m Tc-PSMA-RGS detected additional metastases as small as 3mm in two patients. Thirteen patients suffered from complications related to surgery (Clavien-Dindo grade 1: 12 patients; grade 3a: one patient). A PSA reduction below 0.2 ng/ml was observed in 20 patients. Thirteen patients remained biochemical recurrence free after a median follow

  8. Technetium-99 conjugated with methylene diphosphonate ameliorates ovariectomy-induced osteoporotic phenotype without causing osteonecrosis in the jaw.

    PubMed

    Zhao, Yinghua; Wang, Lei; Liu, Yi; Akiyama, Kentaro; Chen, Chider; Atsuta, Ikiru; Zhou, Tao; Duan, Xiaohong; Jin, Yan; Shi, Songtao

    2012-12-01

    Technetium-99 conjugated with methylene diphosphonate ((99)Tc-MDP) is a novel bisphosphonate derivative without radioactivity and has been successfully used to treat arthritis in China for years. Since bisphosphonate therapy has the potential to induce bisphosphonate-related osteonecrosis of the jaw (BRONJ), we examined whether (99)Tc-MDP represents a new class of bisphosphonate for antiresorptive therapy to ameliorate estrogen deficiency-induced bone resorption with less risk of causing BRONJ. We showed that (99)Tc-MDP-treated, ovariectomized (OVX) mice had significantly improved bone mineral density and trabecular bone volume in comparison to the untreated OVX group by inhibiting osteoclasts and enhancing osteogenic differentiation of bone marrow mesenchymal stem cells. To determine the potential of inducing BRONJ, (99)Tc-MDP/dexamethasone (Dex) or zoledronate/Dex was administered into C57BL/6J mice via the tail vein, followed by extraction of maxillary first molars. Interestingly, (99)Tc-MDP treatment showed less risk to induce osteonecrosis in the maxillary bones compared to zoledronate treatment group, partially because (99)Tc-MDP neither suppressed adaptive regulatory T cells nor activated the inflammatory T-helper-producing interleukin-17 cells. Taken together, our findings demonstrate that (99)Tc-MDP therapy may be a promising approach in the treatment of osteoporosis with less risk of causing BRONJ.

  9. Options for the Separation and Immobilization of Technetium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Serne, R Jeffrey; Crum, Jarrod V.; Riley, Brian J.

    Among radioactive constituents present in the Hanford tank waste, technetium-99 (Tc) presents a unique challenge in that it is significantly radiotoxic, exists predominantly in the liquid low-activity waste (LAW), and has proven difficult to effectively stabilize in a waste form for ultimate disposal. Within the Hanford Tank Waste Treatment and Immobilization Plant, the LAW fraction will be converted to a glass waste form in the LAW vitrification facility, but a significant fraction of Tc volatilizes at the high glass-melting temperatures and is captured in the off-gas treatment system. This necessitates recycle of the off-gas condensate solution to the LAW glassmore » melter feed. The recycle process is effective in increasing the loading of Tc in the immobilized LAW (ILAW), but it also disproportionately increases the sulfur and halides in the LAW melter feed, which have limited solubility in the LAW glass and thus significantly reduce the amount of LAW (glass waste loading) that can be vitrified and still maintain good waste form properties. This increases both the amount of LAW glass and either the duration of the LAW vitrification mission or requires the need for supplemental LAW treatment capacity. Several options are being considered to address this issue. Two approaches attempt to minimize the off-gas recycle by removing Tc at one of several possible points within the tank waste processing flowsheet. The separated Tc from these two approaches must then be dispositioned in a manner such that the Tc can be safely disposed. Alternative waste forms that do not have the Tc volatility issues associated with the vitrification process are being sought for immobilization of Tc for subsequent storage and disposal. The first objective of this report is to provide insights into the compositions and volumes of the Tc-bearing waste streams including the ion exchange eluate from processing LAW and the off-gas condensate from the melter. The first step to be assessed

  10. Evaluation of technetium-99m decay on Escherichia coli inactivation: effects of physical or chemical agents.

    PubMed Central

    Silva, C. R.; Valsa, J. O.; Caniné, M. S.; Caldeira-de-Araújo, A.; Bernardo-Filho, M.

    1998-01-01

    Technetium-99m (99mTc) has been used in nuclear medicine and in biomedical research to label molecular and cellular structures employed as radiotracers. Here, we have evaluated, on a DNA repair proficient Escherichia coli strain, the 99mTc decay inactivation and the influence of the (i) pre-treatment with metal ion chelators or of the (ii) treatment with a free radical scavenger on the protection of the cells against the lethal effect of the 99mTc. As SnCl2 is frequently used as a reducing agent in the 99mTc-labeling process, we have also studied the capability of SnCl2 to alter the biological effects induced by the 99mTc decay. As we are exposed to either chemical or physical agents in the nature, we have decided to study a possible influence of the ultraviolet solar radiation in the biological phenomena induced by the 99mTc decay. Our data point out (i) a very important role of the Auger and/or conversion electrons in the cytotoxicity induced by the 99mTc decay; (ii) SnCl2, the metal ion chelators and the free radical scavenger protect the cells against the lethal effect of the 99mTc; and (iii) near-UV does not alter the lethal effect of the 99mTc decay. PMID:9713950

  11. Structural and Perfusion Abnormalities of Brain on MRI and Technetium-99m-ECD SPECT in Children With Cerebral Palsy: A Comparative Study.

    PubMed

    Rana, Kamer Singh; Narwal, Varun; Chauhan, Lokesh; Singh, Giriraj; Sharma, Monica; Chauhan, Suneel

    2016-04-01

    Cerebral palsy has traditionally been associated with hypoxic ischemic brain damage. This study was undertaken to demonstrate structural and perfusion brain abnormalities. Fifty-six children diagnosed clinically as having cerebral palsy were studied between 1 to 14 years of age and were subjected to 3 Tesla magnetic resonance imaging (MRI). Brain and Technetium-99m-ECD brain single-photon emission computed tomography (SPECT) scan. Male to female ratio was 1.8:1 with a mean age of 4.16 ± 2.274 years. Spastic cerebral palsy was the most common type, observed in 91%. Birth asphyxia was the most common etiology (69.6%). White matter changes (73.2%) such as periventricular leukomalacia and corpus callosal thinning were the most common findings on MRI. On SPECT all cases except one revealed perfusion impairments in different regions of brain. MRI is more sensitive in detecting white matter changes, whereas SPECT is better in detecting cortical and subcortical gray matter abnormalities of perfusion. © The Author(s) 2015.

  12. An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule

    PubMed Central

    Miftari, Ramë; Fejza, Ferki; Bicaj, Xhavit; Nura, Adem; Topciu, Valdete; Bajrami, Ismet

    2014-01-01

    Purpose: In cases of thyroid toxic autonomous nodule, anterior projection of Tc-99m pertechnetate image shows a hot nodule that occupies most, or the entire thyroid lobe with near-total or total suppression of the contra lateral lobe. In this case is very difficult to distinguish toxic nodule from lobe agenesis. Our interest was to estimate and determinate the rate of radioactivity when the source with high activity can make total suppression of the second source with low activity in same conditions with thyroid scintigraphy procedures. Material and methodology: Thyroid scintigraphy was performed with Technetium 99 meta stable pertechnetate. A parallel high resolution low energy collimator was used as an energy setting of 140 KeV photo peak for T-99m. Images are acquired at 200 Kilo Counts in the anterior projection with the collimator positioned as close as the patient’s extended neck (approximately in distance of 18 cm). The scintigraphy of thyroid gland was performed 15 minutes after intravenous administration of 1.5 mCi Tc-99m pertechnetate. Technetium 99 meta stable radioactive sources with different activity were used for two scintigraphies studies, performed in same thyroid scintigraphy acquisition procedures. In the first study, were compared the standard source with high activity A=11.2 mCi with sources with variable activities B=1.33 mCi; 1.03 mCi; 0.7 mCi; 0.36 mCi; and 0.16mCi) in distance of 1.5cm from each other sources, which is approximately same with distance between two thyroid lobes. In the second study were compared the sources with low activity in proportion 70:1(source A = 1.5 mCi and source B=0.021mCi). As clinical studies we preferred two different patents with different thyroid disorders. There were one patient with thyroid toxic nodule in the right lobe, therefore the second patient was with left thyroid nodule agenesis. Results: During our examination, we accurately determined that two radioactive sources in proportion 70:1 will be

  13. RHENIUM SOLUBILITY IN BOROSILICATE NUCLEAR WASTE GLASS IMPLICATIONS FOR THE PROCESSING AND IMMOBILIZATION OF TECHNETIUM-99 (AND SUPPORTING INFORMATION WITH GRAPHICAL ABSTRACT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AA KRUGER; A GOEL; CP RODRIGUEZ

    2012-08-13

    The immobilization of 99Tc in a suitable host matrix has proved a challenging task for researchers in the nuclear waste community around the world. At the Hanford site in Washington State in the U.S., the total amount of 99Tc in low-activity waste (LAW) is {approx} 1,300 kg and the current strategy is to immobilize the 99Tc in borosilicate glass with vitrification. In this context, the present article reports on the solubility and retention of rhenium, a nonradioactive surrogate for 99Tc, in a LAW sodium borosilicate glass. Due to the radioactive nature of technetium, rhenium was chosen as a simulant becausemore » of previously established similarities in ionic radii and other chemical aspects. The glasses containing target Re concentrations varying from 0 to10,000 ppm by mass were synthesized in vacuum-sealed quartz ampoules to minimize the loss of Re by volatilization during melting at 1000 DC. The rhenium was found to be present predominantly as Re7 + in all the glasses as observed by X-ray absorption near-edge structure (XANES). The solubility of Re in borosilicate glasses was determined to be {approx}3,000 ppm (by mass) using inductively coupled plasma-optical emission spectroscopy (ICP-OES). At higher rhenium concentrations, some additional material was retained in the glasses in the form of alkali perrhenate crystalline inclusions detected by X-ray diffraction (XRD) and laser ablation-ICP mass spectrometry (LA-ICP-MS). Assuming justifiably substantial similarities between Re7 + and Tc 7+ behavior in this glass system, these results implied that the processing and immobilization of 99Tc from radioactive wastes should not be limited by the solubility of 99Tc in borosilicate LAW glasses.« less

  14. Early identification of amyloid heart disease by technetium-99m-pyrophosphate scintigraphy: a study with familial amyloid polyneuropathy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hongo, M.; Hirayama, J.; Fujii, T.

    1987-03-01

    To determine whether technetium-99m-pyrophosphate (Tc-99m-PYP) scanning or two-dimensional echocardiography can detect amyloid heart disease in an earlier stage of familial amyloid polyneuropathy, 15 patients were examined. Although 10 of the 15 patients had no clinical evidence of congestive heart failure, as well as normal ventricular wall thickness and normal values for left ventricular systolic function, five (50%) of them showed mild or moderate myocardial uptake. On the other hand, none had characteristic highly refractile myocardial echoes on the two-dimensional echocardiographic images (p less than 0.01), and values for diastolic function were reduced in four of the five and normal inmore » the remaining one. In 85 control subjects, diffuse positive pyrophosphate scans of the heart were found in four (5%) of them (three with dilated cardiomyopathy and one with sarcoidosis), and highly refractile granular sparkling echoes were observed in nine (11%) (five with hypertrophic cardiomyopathy, three with aortic stenosis, and one with hypereosinophilic syndrome). We conclude that Tc-99m-PYP scanning is a more sensitive and specific method and may have the potential ability to detect amyloid heart disease in the earlier stage of familial amyloid polyneuropathy than two-dimensional echocardiography.« less

  15. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Technetium-97m 100 Technetium-97 100 Technetium-99m 100 Technetium-99 10 Tellurium-125m 10 Tellurium-127m 10 Tellurium-127 100 Tellurium-129m 10 Tellurium-129 100 Tellurium-131m 10 Tellurium-132 10...

  16. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Technetium-97m 100 Technetium-97 100 Technetium-99m 100 Technetium-99 10 Tellurium-125m 10 Tellurium-127m 10 Tellurium-127 100 Tellurium-129m 10 Tellurium-129 100 Tellurium-131m 10 Tellurium-132 10...

  17. THE RESULTS OF PARATHYROID HORMONE ASSAY IN PARATHYROID ASPIRATES IN PRE-OPERATIVE LOCALIZATION OF PARATHYROID ADENOMAS FOR FOCUSED PARATHYROIDECTOMY IN PATIENTS WITH NEGATIVE OR SUSPICIOUS TECHNETIUM-99M-SESTAMIBI SCANS.

    PubMed

    Ozderya, Aysenur; Temizkan, Sule; Cetin, Kenan; Ozugur, Sule; Gul, Aylin Ege; Aydin, Kadriye

    2017-09-01

    This study aimed to evaluate the results of parathyroid hormone (PTH) assay in parathyroid aspirates to determine uniglandular disease by an endocrinologist-performed ultrasound (US) in patients with discordant or negative technetium-sestamibi scans and to evaluate whether this procedure increases the number of focused parathyroidectomies (FPs). We analyzed the data of 65 patients who underwent an endocrinologist-performed US-guided parathyroid fine-needle aspiration (FNA) with PTH wash-out, retrospectively. The results of PTH wash-out procedure and the reports of parathyroid surgery and pathology were reviewed. Of 65 patients, 54 had positive PTH wash-out results. The median serum PTH level of patients with positive and negative PTH wash-out results was 143 (25 and 75% interquartile range [IQR], 114 to 197) versus 154 (IQR, 115 to 255) pg/mL (P = .45), and the median PTH in FNA was 3,533 (IQR, 1,481 to 3,534) versus 6.0 (IQR, 1 to 6) pg/mL (P<.001), respectively. Forty-five patients underwent surgery. Of the operated patients, 42 had positive PTH wash-out results and had successful FP. Four patients with redo surgery had positive PTH wash-out results and were successfully re-operated with FP. Of 11 patients with negative PTH wash-out results, 3 had bilateral neck exploration (BNE) surgery and 2 patients were successfully operated, while surgery was unsuccessful in 1 patient, despite BNE. Our study results suggest that endocrinologist-performed US and parathyroid FNA with PTH wash-out increases the number and success of FPs. In particular, patients with redo surgery may benefit from this procedure. 4D-CT = four-dimensional computed tomography BNE = bilateral neck exploration FNA = fine-needle aspiration FNAB = fine-needle aspiration biopsy FP = focused parathyroidectomy IQR = 25 and 75% inter-quartile range PHPT = primary hyperparathyroidism PPV = positive predictive value PTH = parathyroid hormone 99m Tc = technetium US = ultrasound.

  18. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    PubMed

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS <4. Parameters such as age, body mass index, waist perimeter, smoking habits, and medical history (diabetes mellitus, dyslipidemia, etc) were evaluated according to MPI results. Myocardial ischemia was present in 32 (62%) of 52 patients with stroke. Among them, 20 (62%) of 32 patients had mild abnormalities and 12 (38%) of 32 had moderate/severe. The age and waist perimeter showed a tendency to relate to severe MIS when patients with SSS >9 were compared to patients with SSS <4. In MPI-positive patients, an age was to be association with SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  19. [Situation of supply and boom of PET imaging: what is the future for technetium-99m in nuclear medicine?].

    PubMed

    Maia, S; Ayachi Hatit, N; Paycha, F

    2011-05-01

    Molecular imaging has shown its interest in the diagnosis, staging and therapy monitoring of many diseases, especially in the field of cancer. This imaging modality can detect non-invasively early molecular changes specific to these diseases. Its expansion includes two aspects linked firstly with the advanced techniques of imaging modalities and secondly with the development of tracers as radio pharmaceuticals for imaging new molecular targets. Technetium-99m ((99m)Tc), because of its physical characteristics, its widespread availability and low cost, is the most used radionuclide in molecular imaging with the technique of single photon emission computed tomography (SPECT). Nevertheless, the current difficulty concerning the supply and the great interest of Positron Emission Tomography (PET), the "competitor" imaging modality-using molecules labelled with fluorine-18 ((18)F), legitimates the question about the future of (99m)Tc, its supremacy and the emergence of new tracer labelled with (99m)Tc. Focusing on the actual and future supply situation, the place of SPECT imaging in nuclear medicine, as well as the development of new molecules labelled with (99m)Tc is necessary to show that this radionuclide will remain essential for the speciality in the next years. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  20. Dissimilar behavior of technetium and rhenium in borosilicatewaste glass as determined by X-ray absorption spectroscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lukens, Wayne W.; McKeown, David A.; Buechele, Andrew C.

    2006-11-09

    Technetium-99 is an abundant, long-lived (t1/2 = 213,000 yr)fission product that creates challenges for the safe, long-term disposalof nuclear waste. While 99Tc receives attention largely due to its highenvironmental mobility, it also causes problems during its incorporationinto nuclear waste glass due to the volatility of Tc(VII) compounds. Thisvolatility decreases the amount of 99Tc stabilized in the waste glass andcauses contamination of the waste glass melter and off-gas system. Theapproach to decrease the volatility of 99Tc that has received the mostattention is reduction of the volatile Tc(VII) species to less volatileTc(IV) species in the glass melt. On engineering scale experiments,rhenium ismore » often used as a non-radioactive surrogate for 99Tc to avoidthe radioactive contamination problems caused by volatile 99Tc compounds.However, Re(VII) is more stable towards reduction than Tc(VII), so morereducing conditions would be required in the glass melt to produceRe(IV). To better understand the redox behavior of Tc and Re in nuclearwaste glass, a series of glasses were prepared under different redoxconditions. The speciation of Tc and Re in the resulting glasses wasdetermined by X-ray absorption fine structure spectroscopy. Surprisingly,Re and Tc do not behave similarly in the glass melt. Although Tc(0),Tc(IV), and Tc(VII) were observed in these samples, only Re(0) andRe(VII) were found. In no case was Re(IV) (or Re(VI))observed.« less

  1. Recruitment of 99m-technetium- or 111-indium-labelled polymorphonuclear leucocytes in experimentally induced pyogranulomas in lambs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guilloteau, L.; Pepin, M.; Pardon, P.

    1990-10-01

    The recruitment of polymorphonuclear leucocytes (PMNs) during the development of experimental pyogranulomas induced by Corynebacterium pseudotuberculosis was followed in nine male lambs by scintigraphic examination. Autologous blood PMNs were labelled with 99m-technetium or 111-indium and were re-injected intravenously into infected lambs. The functional properties of the labelled cells were monitored (1) in vitro by measuring their phagocytic and bactericidal activity against C. pseudotuberculosis and their chemotaxis under agarose, and (2) in vivo by following scintigraphically their capacity to accumulate in an inflammatory focus induced by intradermal injection of latex beads coated with Salmonella abortus equi lipopolysaccharide. Following inoculation of corynebacteriamore » into the right ear of lambs, radioactive foci were observed to be localized in the right ear and in the draining lymph nodes during the 4 days following inoculation. Histopathological examination performed 32 h after inoculation confirmed the intense accumulation of PMNs at these sites. With the exception of one animal, which presented visible foci in the neck 14 days postinoculation, no radioactive foci were observed during the later phases of experimental infection, despite the presence of multiple pyogranulomas which were confirmed by bacteriological examination after necropsy of the lambs. Histopathological examination of these lesions revealed layers of fibroblasts, lymphocytes, and macrophages surrounding a necrotic centre. The results of these studies suggest that the contribution of PMNs during the chronic phase of inflammation is considerably reduced in comparison with the acute inflammatory phase of the infectious process.« less

  2. Comparison of technetium-99m-HM-PAO leukocytes with indium-111-oxine leukocytes for localizing intraabdominal sepsis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mountford, P.J.; Kettle, A.G.; O'Doherty, M.J.

    Technetium-99m-HM-PAO (({sup 99m}Tc)HM-PAO) leukocyte and indium-111-oxine (111In-oxine) leukocyte scanning were carried out simultaneously in 41 patients at 4 hr and 24 hr after reinjection to determine whether the 4-hr {sup 99m}Tc scan could replace the 24-hr {sup 111}In scan for detecting intraabdominal sepsis. Abdominal infection was confirmed in 12 cases. The 4-hr {sup 99}Tc-leukocyte scan, the 4-hr {sup 111}In-leukocyte scan, and the 24-hr {sup 111}In-leukocyte scan yielded a sensitivity of 100%, 67%, and 100%, respectively, and a specificity of 62%, 90%, and 86%, respectively. The 24-hr {sup 99m}Tc-leukocyte scan also produced a sensitivity of 100%, but it was falsely positivemore » in all 29 cases without infection due to physiologic bowel uptake. False-positive 4-hr {sup 99m}Tc-leukocyte scans were also produced by physiologic bowel uptake in seven cases all of whom had true-negative 4-hr and 24-hr {sup 111}In-leukocyte scans. Because of the high incidence of false-positive 4-hr ({sup 99m}Tc)HM-PAO leukocyte scans, it was concluded that they could not replace 24-hr {sup 111}In-leukocyte scans for detecting intraabdominal sepsis, and that serial {sup 99m}Tc leukocyte scans starting earlier than 4 hr after reinjection must be evaluated.« less

  3. Photoreduction of 99Tc Pertechnetate by Nanometer-Sized Metal Oxides: New Strategies for Formation and Sequestration of Low-Valent Technetium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burton-Pye, Benjamin P.; Radivojevic, Ivana; McGregor, Donna

    2011-11-23

    Technetium-99 ( 99Tc)(β - max: 293.7 keV; t 1/2: 2.1 x 10 5 years) is a byproduct of uranium-235 fission and comprises a large component of radioactive waste. Under aerobic conditions and in a neutral- basic environment, the pertechnetate anion ( 99TcO 4 -) is stable. 99TcO 4 - is very soluble, migrates easily through the environment and does not sorb well onto mineral surfaces, soils or sediments. This study moves forward a new strategy for the reduction of TcO 4 - and chemical incorporation of the reduced 99Tc into a metal oxide material. This strategy employs a single material,more » a polyoxometalate (POM), α 2-[P 2W 17O 61] 10-, that can be photoactivated in the presence of 2-propanol to transfer electrons to TcO 4 - and incorporate the reduced 99Tc covalently into the α 2 - framework to form the Tc VO species, Tc VO(α 2-P 2W 17O 61) 7-. This occurs via the formation of an intermediate species that slowly converts to Tc VO(α 2-P 2W 17O 61) 7-. EXAFS and XANES analysis and preliminary EPR analysis, suggests that the intermediate consists of a Tc(IV) α 2- species where the 99Tc is likely bound to only 2 of the 4 W-O oxygen atoms in the α 2-[P 2W 17O 61] 10- defect. This intermediate then oxidizes and converts to the 99Tc VO(α 2-P 2W 17O 61) 7- product. The reduction and incorporation of 99TcO 4- was accomplished in a ''one pot'' reaction using both sunlight and UV irradiation, and monitored as a function of time using multinuclear NMR and radio TLC. The process was further probed by the ''step-wise'' generation of reduced α 2-P 2W 17O 61 12- through bulk electrolysis followed by the addition of TcO 4 -. The reduction and incorporation of ReO 4 -, as a non-radioactive surrogate for 99Tc, does not proceed through the intermediate species, and Re VO is incorporated quickly into the α 2-[P 2W 17O 61] 10- defect. These observations are consistent with the periodic trends of 99Tc and Re. Specifically, 99Tc is more easily reduced compared to Re. In addition

  4. Use of technetium-99m methylene diphosphonate and gallium-67 citrate scans after intraarticular injection of Staphylococcus aureus into knee joints of rabbits with chronic antigen-induced arthritis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mahowald, M.L.; Raskind, J.R.; Peterson, L.

    1986-08-01

    Numerous clinical studies have questioned the ability of radionuclide scans to differentiate septic from aseptic joint inflammation. A clinical study may not be able to document an underlying disease process or duration of infection and, thus, may make conclusions about the accuracy of scan interpretations open to debate. In this study, the Dumonde-Glynn model of antigen-induced arthritis in rabbits was used as the experimental model to study technetium and gallium scans in Staphylococcus aureus infection of arthritic and normal joints. Gallium scans were negative in normal rabbits, usually negative in antigen-induced arthritis, but positive in septic arthritis. The bone scanmore » was usually negative in early infection but positive in late septic arthritis, a finding reflecting greater penetration of bacteria into subchondral bone because of the underlying inflammatory process.« less

  5. Tc-99 Decontamination From Heat Treated Gaseous Diffusion Membrane -Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L.; Wilmarth, B.; Restivo, M.

    2017-03-13

    Uranium gaseous diffusion cascades represent a significant environmental challenge to dismantle, containerize and dispose as low-level radioactive waste. Baseline technologies rely on manual manipulations involving direct access to technetium-contaminated piping and materials. There is a potential to utilize novel thermal decontamination technologies to remove the technetium and allow for on-site disposal of the very large uranium converters. Technetium entered these gaseous diffusion cascades as a hexafluoride complex in the same fashion as uranium. Technetium, as the isotope Tc-99, is an impurity that follows uranium in the first cycle of the Plutonium and Uranium Extraction (PUREX) process. The technetium speciation ormore » exact form in the gas diffusion cascades is not well defined. Several forms of Tc-99 compounds, mostly the fluorinated technetium compounds with varying degrees of volatility have been speculated by the scientific community to be present in these cascades. Therefore, there may be a possibility of using thermal desorption, which is independent of the technetium oxidation states, to perform an in situ removal of the technetium as a volatile species and trap the radionuclide on sorbent traps which could be disposed as low-level waste.« less

  6. Design and characterization of α-melanotropin peptide analogs cyclized through rhenium and technetium metal coordination

    PubMed Central

    Giblin, Michael F.; Wang, Nannan; Hoffman, Timothy J.; Jurisson, Silvia S.; Quinn, Thomas P.

    1998-01-01

    α-Melanocyte stimulating hormone (α-MSH) analogs, cyclized through site-specific rhenium (Re) and technetium (Tc) metal coordination, were structurally characterized and analyzed for their abilities to bind α-MSH receptors present on melanoma cells and in tumor-bearing mice. Results from receptor-binding assays conducted with B16 F1 murine melanoma cells indicated that receptor-binding affinity was reduced to approximately 1% of its original levels after Re incorporation into the cyclic Cys4,10, d-Phe7–α-MSH4-13 analog. Structural analysis of the Re–peptide complex showed that the disulfide bond of the original peptide was replaced by thiolate–metal–thiolate cyclization. A comparison of the metal-bound and metal-free structures indicated that metal complexation dramatically altered the structure of the receptor-binding core sequence. Redesign of the metal binding site resulted in a second-generation Re–peptide complex (ReCCMSH) that displayed a receptor-binding affinity of 2.9 nM, 25-fold higher than the initial Re–α-MSH analog. Characterization of the second-generation Re–peptide complex indicated that the peptide was still cyclized through Re coordination, but the structure of the receptor-binding sequence was no longer constrained. The corresponding 99mTc- and 188ReCCMSH complexes were synthesized and shown to be stable in phosphate-buffered saline and to challenges from diethylenetriaminepentaacetic acid (DTPA) and free cysteine. In vivo, the 99mTcCCMSH complex exhibited significant tumor uptake and retention and was effective in imaging melanoma in a murine-tumor model system. Cyclization of α-MSH analogs via 99mTc and 188Re yields chemically stable and biologically active molecules with potential melanoma-imaging and therapeutic properties. PMID:9788997

  7. The use of technetium-99m-labeled human serum albumin diethylenetriamine pentaacetic acid single-photon emission CT scan in the follow-up of type II endoleak treatment.

    PubMed

    Nakai, Motoki; Sato, Hirotatsu; Ikoma, Akira; Sonomura, Tetsuo; Sato, Morio

    2014-03-01

    An 84-year-old woman presented with persistent type II endoleak with sac expansion from 57 mm to 75 mm during 4-year follow-up after endovascular abdominal aortic aneurysm repair. The patient underwent transabdominal embolization with coils and N-butyl cyanoacrylate/ethiodized oil (Lipiodol; Guerbet, Villepinte, France) mixture (2.5 mL). Because of the anticipated embolization artifacts on follow-up computed tomography (CT), technetium-99m-labeled human serum albumin diethylenetriamine pentaacetic acid single-photon emission computed tomography ((99m)Tc-HSAD SPECT) was performed before and after the intervention. Perigraft accumulation on (99m)Tc-HSAD SPECT corresponding to the endoleak disappeared after embolization. CT scan performed 12 months after embolization showed no signs of sac expansion. (99m)Tc-HSAD SPECT may be useful for evaluating therapeutic effect after embolization for endoleak. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  8. Calculation of therapeutic activity of radioiodine in Graves' disease by means of Marinelli's formula, using technetium (99mTc) scintigraphy.

    PubMed

    Szumowski, Piotr; Mojsak, Małgorzata; Abdelrazek, Saeid; Sykała, Monika; Amelian-Fiłonowicz, Anna; Jurgilewicz, Dorota; Myśliwiec, Janusz

    2016-12-01

    The therapeutic activity of 131 I administered to patients with Graves' disease can be calculated by means of Marinelli's formula. The thyroidal iodine uptake ( 131 IU max ) needed for the calculation is usually determined with the use of 131 I. The purpose of the paper was to estimate 131 IU max on the basis of technetium uptake in the thyroid at 20 min ( 99m TcU 20min ). Eighty patients suffering from Graves' disease were qualified for radioiodine therapy with measurement of fT 4 , fT 3 , thyroid-stimulating hormone and its receptor (TRAb). Prior to the treatment, all the patients were euthyroid. 131 IU max for each patient was determined according to the levels of 131 I after 24 h ( 131 IU 24h ), while effective half-life (T eff ) according to the measurements of 131 IU 24h and 131 I uptake after 48 h ( 131 IU 48h ). Additionally, on the day before measuring 131 IU 24h , 99m TcU 20min was calculated for each patient. It was demonstrated that there existed a correlation, with statistical significance at p < 0.05, between the following pairs of values: TRAb and 131 IU 24h , TRAb and 99m TcU 20min , and 99m TcU 20min and 131 IU 24h . The interdependence between 131 IU 24h and 99m TcU 20min at the level of significance p < 0.05 is described by the following algorithms: 131 IU 24h  = 17.72 × ln ( 99m TcU 20min ) + 30.485, if TRAb < 10 IU/ml, and 131 IU 24h  = 18.03 × ln ( 99m TcU 20min ) + 38.726, if TRAb > 10 IU/ml. It is possible to predict thyroid iodine uptake 131 IU 24h in Graves' disease on the basis of measuring the uptake of 99m TcU 20min . This shortens the time necessary for diagnosis and enables the calculation of 131 I activity using Marinelli's formula.

  9. Effect of Thuya occidentalis on the labeling of red blood cells and plasma proteins with technetium-99m.

    PubMed Central

    Oliveira, J. F.; Braga, A. C.; Avila, A. S.; Fonseca, L. M.; Gutfilen, B.; Bernardo-Filho, M.

    1996-01-01

    Thuya occidentalis is used in popular medicine in the treatment of condyloma and has antibacterial action. Red blood cells (RBC) labeled with technetium-99m (99mTc) are used for several evaluations in nuclear medicine. This labeling depends on a reducing agent, usually stannous ion. Any drug which alters the labeling of the tracer could be expected to modify the disposition of the radiopharmaceutical. We have evaluated the influence of T. occidentalis extract on the labeling of RBC and plasma proteins with 99mTc. Blood was withdrawn and incubated with T. occidentalis (0.25; 2.5; 20.5; and 34.1 percent v/v). Stannous chloride (1.2 micrograms/ml) was added and then 99mTc was added. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) separated. The analysis of the results shows that there is a decrease in radioactivity (from 97.64 to 75.89 percent) in BC with 34.1 percent of the drug. In the labeling process of RBC with 99mTc, the stannous and pertechnetate ions pass through the membrane, so we suggest that the T. occidentalis effect can be explained (i) by an inhibition of the transport of these ions, (ii) by damage in membrane, (iii) by competition with the cited ions for the same binding sites, or (iv) by possible generation of reactive oxygen species that could oxidize the stannous ion. PMID:9436292

  10. Effect of Thuya occidentalis on the labeling of red blood cells and plasma proteins with technetium-99m.

    PubMed

    Oliveira, J F; Braga, A C; Avila, A S; Fonseca, L M; Gutfilen, B; Bernardo-Filho, M

    1996-01-01

    Thuya occidentalis is used in popular medicine in the treatment of condyloma and has antibacterial action. Red blood cells (RBC) labeled with technetium-99m (99mTc) are used for several evaluations in nuclear medicine. This labeling depends on a reducing agent, usually stannous ion. Any drug which alters the labeling of the tracer could be expected to modify the disposition of the radiopharmaceutical. We have evaluated the influence of T. occidentalis extract on the labeling of RBC and plasma proteins with 99mTc. Blood was withdrawn and incubated with T. occidentalis (0.25; 2.5; 20.5; and 34.1 percent v/v). Stannous chloride (1.2 micrograms/ml) was added and then 99mTc was added. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) separated. The analysis of the results shows that there is a decrease in radioactivity (from 97.64 to 75.89 percent) in BC with 34.1 percent of the drug. In the labeling process of RBC with 99mTc, the stannous and pertechnetate ions pass through the membrane, so we suggest that the T. occidentalis effect can be explained (i) by an inhibition of the transport of these ions, (ii) by damage in membrane, (iii) by competition with the cited ions for the same binding sites, or (iv) by possible generation of reactive oxygen species that could oxidize the stannous ion.

  11. Real-time gamma imaging of technetium transport through natural and engineered porous materials for radioactive waste disposal.

    PubMed

    Corkhill, Claire L; Bridge, Jonathan W; Chen, Xiaohui C; Hillel, Phil; Thornton, Steve F; Romero-Gonzalez, Maria E; Banwart, Steven A; Hyatt, Neil C

    2013-12-03

    We present a novel methodology for determining the transport of technetium-99m, a γ-emitting metastable isomer of (99)Tc, through quartz sand and porous media relevant to the disposal of nuclear waste in a geological disposal facility (GDF). Quartz sand is utilized as a model medium, and the applicability of the methodology to determine radionuclide transport in engineered backfill cement is explored using the UK GDF candidate backfill cement, Nirex Reference Vault Backfill (NRVB), in a model system. Two-dimensional distributions in (99m)Tc activity were collected at millimeter-resolution using decay-corrected gamma camera images. Pulse-inputs of ~20 MBq (99m)Tc were introduced into short (<10 cm) water-saturated columns at a constant flow of 0.33 mL min(-1). Changes in calibrated mass distribution of (99m)Tc at 30 s intervals, over a period of several hours, were quantified by spatial moments analysis. Transport parameters were fitted to the experimental data using a one-dimensional convection-dispersion equation, yielding transport properties for this radionuclide in a model GDF environment. These data demonstrate that (99)Tc in the pertechnetate form (Tc(VII)O4(-)) does not sorb to cement backfill during transport under model conditions, resulting in closely conservative transport behavior. This methodology represents a quantitative development of radiotracer imaging and offers the opportunity to conveniently and rapidly characterize transport of gamma-emitting isotopes in opaque media, relevant to the geological disposal of nuclear waste and potentially to a wide variety of other subsurface environments.

  12. Real-Time Gamma Imaging of Technetium Transport through Natural and Engineered Porous Materials for Radioactive Waste Disposal

    PubMed Central

    2013-01-01

    We present a novel methodology for determining the transport of technetium-99m, a γ-emitting metastable isomer of 99Tc, through quartz sand and porous media relevant to the disposal of nuclear waste in a geological disposal facility (GDF). Quartz sand is utilized as a model medium, and the applicability of the methodology to determine radionuclide transport in engineered backfill cement is explored using the UK GDF candidate backfill cement, Nirex Reference Vault Backfill (NRVB), in a model system. Two-dimensional distributions in 99mTc activity were collected at millimeter-resolution using decay-corrected gamma camera images. Pulse-inputs of ∼20 MBq 99mTc were introduced into short (<10 cm) water-saturated columns at a constant flow of 0.33 mL min–1. Changes in calibrated mass distribution of 99mTc at 30 s intervals, over a period of several hours, were quantified by spatial moments analysis. Transport parameters were fitted to the experimental data using a one-dimensional convection–dispersion equation, yielding transport properties for this radionuclide in a model GDF environment. These data demonstrate that 99Tc in the pertechnetate form (Tc(VII)O4–) does not sorb to cement backfill during transport under model conditions, resulting in closely conservative transport behavior. This methodology represents a quantitative development of radiotracer imaging and offers the opportunity to conveniently and rapidly characterize transport of gamma-emitting isotopes in opaque media, relevant to the geological disposal of nuclear waste and potentially to a wide variety of other subsurface environments. PMID:24147650

  13. Radionuclide Sensors and Systems for Monitoring Technetium-99 and Strontium-90 in Groundwater at the Hanford Site

    NASA Astrophysics Data System (ADS)

    Grate, J. W.; O'Hara, M. J.; Egorov, O. B.; Burge, S. R.

    2009-12-01

    We have developed automated sensor and analyzer devices for detection and monitoring of trace radionuclides in water, using preconcentrating columns and radiometric detection. The preconcentrating minicolumn sensor concept combines selective capture and detection in a single functional unit, where the column contains tens to hundreds of milligrams of selectively sorbent material, and the entire column content is monitored with a radiometric detector. Compared to thin film sensors with a few microgram of sorbent, this approach achieves tremendous preconcentration with efficient mass transport via pumping. Furthermore, in an equilibration-based mode of operation, the preconcentration by the sensor is maximized while eliminating the need for consumable reagents to regenerate the column; it can simply be re-equilibrated. We have demonstrated quantification of radionuclides such as technetium-99 to levels below drinking water standards in an equilibration-based process that produces steady state signals, signal proportional to concentration, and easy re-equilibration to new concentration levels. Alternatively, analyzers can be developed with separate separation and detection units that are fluidically linked. We have demonstrated detection of strontium-90 to levels below drinking water standards by this approach. We are developing autonomous systems for at-site monitoring on the Hanford Site in Washington State, using the fluidic sensor and analyzer methods, with the aim of monitoring natural and accelerated attenuation processes, remediation and barrier performance, and contaminant fluxes in the environment. Figure 1. The strontium-90 monitoring method deployed as part of the Burge Environmental Universal Sensor Platform, shown on the shores of the Columbia River on the Hanford site in Washington State.

  14. Measurement of translymphatic fluid absorption using technetium-99m human serum albumin diethylenetriamine pentaacetic acid in continuous ambulatory peritoneal dialysis patients.

    PubMed

    Terawaki, Hiroyuki; Nakayama, Masaaki; Seto, Kazuhiko; Yoshimura, Kazunobu; Hasegawa, Toshio

    2004-08-01

    We have established a new method of measuring translymphatic fluid absorption (TLA) using technetium-99m ((99m)Tc) human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) that can be used commonly in clinical practice. This new method was applied in 13 continuous ambulatory peritoneal dialysis patients (11 males and two females) who had various peritoneal permeability and capacities for peritoneal transport of water. (99m)Tc-HSAD 740MBq was injected in 2 L of peritoneal dialysis fluid with 2.5% glucose, mixed well, and administered intraperitoneally. The fluid was drained extraperitoneally after 4 h and TLA was determined by the in vivo loss of (99m)Tc-HSAD. TLA was 1.41 +/- 1.11 mL/min (mean +/- SD; range, 0.27-3.69 mL/min). The estimated reduction rate by TLA in trans-peritoneally removed fluid ranged from 14.2 to 84.4%, indicating that TLA could have an extremely significant negative effect in some cases on total drainage volume. The present study, using new tracer (99m)Tc-HSAD, could confirm a large individual difference in TLA, indicating TLA as an important contributing factor for fluid-removal failure in continuous ambulatory peritoneal dialysis patients.

  15. Technetium-99m sestamibi scintimammography complements mammography in the detection of breast cancer.

    PubMed

    Krishnaiah, Gayathri; Sher-Ahmed, Arifa; Ugwu-Dike, Martins; Regan, Patricia; Singer, John; Totoonchie, Adil; Spiegler, Ethan; Sardi, Armando

    2003-01-01

    Mammography remains the technique of choice for the detection of early breast cancer. The sensitivity of mammography is 85%, but is decreased in patients with dense breasts. Sestamibi scintimammography (SCM) has been suggested as an adjunctive modality to improve the detection of breast cancer. We conducted a study to determine the impact of SCM in patient management. A prospective study was conducted in 95 patients presenting with palpable masses and/or abnormal mammography scheduled for biopsy. Injection of 20-30 mCi of technetium-99m (Tc-99m) sestamibi into a pedal vein was performed. Ten-minute images of the breast and axilla were obtained in multiple projections. The mammography and SCM were correlated with pathology and clinical findings. The median age was 44 years (range 28-86 years). The total number of lesions was 104, as eight patients had bilateral lesions and one patient had two lesions in the same breast. Fifty-nine patients presented with palpable lesions and 45 patients with nonpalpable lesions (42 with abnormal mammography only and 3 with nipple discharge). A comparison of sensitivity, specificity, positive and negative predictive values, and overall accuracy of SCM and mammography were performed. The sensitivity and specificity for SCM were 83% and 83%, respectively, and for mammography were 65%, and 72%, respectively. The sensitivity and specificity for combined SCM and mammography were 87% and 94%, respectively. The p-value for mammography versus combined SCM and mammography was 0.0003 and that for SCM versus SCM and mammography was 0.0098. There were 80 (77%) benign and 24 (23%) malignant lesions. Of the 24 malignancies, SCM missed six (25%), versus eight (33%) by mammography. In two patients (9%) SCM detected malignancy in the breast that was not visualized by mammography or found on clinical examination. Sestamibi SCM improves the sensitivity of mammography and it detects up to 9% of malignancies not detected by mammography or clinical

  16. Technetium-99 cycling in maple trees: characterization of changes in chemical form.

    PubMed

    Garten, C T; Lomax, R D

    1989-08-01

    Prior field studies near an old radioactive waste disposal site at Oak Ridge, TN, indicated that following root uptake, metabolism by deciduous trees rendered 99Tc less biogeochemically mobile than expected, based on chemistry of the pertechnetate (TcO-4) anion. Subsequently, the form of technetium (Tc) in maple tree (Acer sp.) sap, leaves, wood and forest leaf litter was characterized using one or more of the following methods: dialysis, physical fractionation, chemical extraction, gel permeation chromatography, enzymatic extraction, or thin layer chromatography (TLC) on silica gel. Chromatography (Sephadex G-25) of TcO-4 incubated in vitro with tree sap showed it to behave similar to TcO-4 anion. When labeled wood and leaf tissues were processed using a tissue homogenizer, 15% and 40%, respectively, of the Tc was solubilized into phosphate buffer. Most (65% to 80%) of the solubilized Tc passing a 0.45-micron filter also passed through an ultrafiltration membrane with a nominal molecular weight cutoff of 10,000 atomic mass units (amu). A majority (72% to 80%) of the Tc in wood could be chemically removed by successive extractions with ethanol, water and weak mineral acid. These same extractants removed only 23% to 31% of the Tc from maple leaves or forest floor leaf litter. Most of the Tc in leaves and leaf litter was removed only by strongly alkaline reagents typically used to release structural polysaccharides (hemicelluloses) from plant tissues. Chromatography (Sephadex G-25) of the ethanol-water extract from wood and the alkaline extract from leaves demonstrated that Tc in these extracts was not principally TcO-4 but was complexed with molecules greater than 1000 amu. Incubations of leaf and wood homogenates with protease approximately doubled the amount of Tc released from contaminated tissues. Ultrafiltration of protease-solubilized Tc from leaves and wood showed that 40% and 93%, respectively, of the Tc was less than 10,000 amu. TLC of the less than 10

  17. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid in healthy individuals

    PubMed Central

    de Albuquerque, Isabella Martins; Cardoso, Dannuey Machado; Masiero, Paulo Ricardo; Paiva, Dulciane Nunes; Resqueti, Vanessa Regiane; Fregonezi, Guilherme Augusto de Freitas; Menna-Barreto, Sérgio Saldanha

    2016-01-01

    ABSTRACT Objective: To evaluate the effects of positive expiratory pressure (PEP) on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females) with a mean age of 28.3 ± 5.4 years, a mean FEV1/FVC ratio of 0.89 ± 0.14, and a mean FEV1 of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA) radioaerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels-10 cmH2O (n = 10), 15 cmH2O (n = 10), and 20 cmH2O (n = 10). The 99mTc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of 99mTc-DTPA was significantly shorter when PEP was applied-at 10 cmH2O (p = 0.044), 15 cmH2O (p = 0.044), and 20 cmH2O (p = 0.004)-in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects. PMID:28117469

  18. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement.

    PubMed

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    99m Technetium-methylene diphosphonate ( 99m Tc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99m Tc-MDP-bone scan images. A set of 89 low contrast 99m Tc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t -test was applied, and a statistically significant difference in the input and processed image quality was found at P < 0.001 (with α = 0.05). However, further improvement in image quality is needed as per requirements of nuclear medicine physicians. GHE techniques can be used on low contrast bone scan images. In some of the cases, a histogram equalization technique in combination with some other postprocessing technique is useful.

  19. Process for preparing radiopharmaceuticals

    DOEpatents

    Barak, Morton; Winchell, Harry S.

    1977-01-04

    A process for the preparation of technetium-99m labeled pharmaceuticals is disclosed. The process comprises initially isolating technetium-99m pertechnetate by adsorption upon an adsorbent packing in a chromatographic column. The technetium-99m is then eluted from the packing with a biological compound to form a radiopharmaceutical.

  20. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement

    PubMed Central

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    Purpose of the Study: 99mTechnetium-methylene diphosphonate (99mTc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99mTc-MDP-bone scan images. Materials and Methods: A set of 89 low contrast 99mTc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. Results: This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t-test was applied, and a statistically significant difference in the input and processed image quality was found at P < 0.001 (with α = 0.05). However, further improvement in image quality is needed as per requirements of nuclear medicine physicians. Conclusion: GHE techniques can be used on low contrast bone scan images. In some of the cases, a histogram equalization technique in combination with some other postprocessing technique is useful. PMID:29142344

  1. Cortical perfusion response to an electrical stimulation of the auditory nerve in profoundly deaf patients: study with technetium-99m hexamethylpropylene amine oxime single photon emission tomography.

    PubMed

    Le Scao, Y; Robier, A; Baulieu, J L; Beutter, P; Pourcelot, L

    1992-01-01

    Brain activation procedures associated with single photon emission tomography (SPET) have recently been developed in healthy controls and diseased patients in order to help in their diagnosis and treatment. We investigated the effects of a promontory test (PT) on the cerebral distribution of technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) in 7 profoundly deaf patients, 6 PT+ and one PT-. The count variation in the temporal lobe was calculated on 6 coronal slices using the ratio (Rstimulation-Rdeprivation)/Rdeprivation where R = counts in the temporal lobe/whole-brain count. A count increase in the temporal lobe was observed in all patients and was higher in all patients with PT+ than in the patient with PT-. The problems of head positioning and resolution of the system were taken into account, and we considered that the maximal count increment was related to the auditory cortex response to the stimulus. Further clinical investigations with high-resolution systems have to be performed in order to validate this presurgery test in cochlear implant assessment.

  2. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lieske, T.R.; Sunderrajan, E.V.; Passamonte, P.M.

    A patient with chronic eosinophilic pneumonia was evaluated using bronchoalveolar lavage, technetium-99m glucoheptonate, and transbronchial lung biopsy. Bronchoalveolar lavage revealed 43 percent eosinophils and correlated well with results of transbronchial lung biopsy. Technetium-99m glucoheptonate lung imaging demonstrated intense parenchymal uptake. After eight weeks of corticosteroid therapy, the bronchoalveolar lavage eosinophil population and the technetium-99m glucoheptonate uptake had returned to normal. We suggest that bronchoalveolar lavage, with transbronchial lung biopsy, is a less invasive way than open lung biopsy to diagnose chronic eosinophilic pneumonia. The mechanism of uptake of technetium-99m glucoheptonate in this disorder remains to be defined.

  3. Technetium-99m-labeled rituximab for use as a specific tracer of sentinel lymph node biopsy: a translational research study.

    PubMed

    Wang, Xuejuan; Yang, Zhi; Lin, Baohe; Zhang, Yan; Zhai, Shizhen; Zhao, Qichao; Xie, Qing; Liu, Fei; Han, Xuedi; Li, Jinfeng; Ouyang, Tao

    2016-06-21

    We aimed to develop and translate a CD20-antigen-targeted radiopharmaceutical, Technetium-99 m-labeled (99mTc) rituximab, for sentinel lymph node (SLN) detection. 99mTc-rituximab was synthesized and tested for stability in human serum. The binding affinity to CD20 was evaluated in Raji cells by flow cytometric analysis. Biodistribution and sentinel node mapping were carried out in bal b/c mice. Eighty-five patients with breast cancer participated in this study. Dynamic sentinel lymphoscintigraphy was first assessed in 12 patients before planar lymphoscintigraphy was assessed in a larger cohort. All patients underwent sentinel lymph node biopsy (SLNB), followed by axillary lymph node dissection. The cell-binding study showed that 99mTc-rituximab possessed compatible affinity to human CD20. In the mechanism study, 99mTc-labeled anti-mouse CD20 monoclonal antibodies could bind to mouse CD20 and accumulate in the SLN with 2.62±1.25 % of the percentage of injected activity, which could be blocked by excessive unlabeled antibody. Low uptake of non-sentinel nodes and fast clearance from the injection site were observed in the mice. Sentinel nodes were identified in 82 of 85 breast cancer patients (96.5%) by lymphoscintigraphy and SLNB. The sensitivity, specificity, and accuracy were 96.8% (30/31), 100% (51/51), and 98.8% (81/82), respectively. 99mTc-rituximab, specifically binding to CD20, met most of the requirements of an ideal sentinel mapping agent for use in clinical settings.

  4. In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy

    PubMed Central

    Dudhia, Jayesh; Becerra, Patricia; Valdés, Miguel A.; Neves, Francisco; Hartman, Neil G.; Smith, Roger K.W.

    2015-01-01

    Recent advances in the application of bone marrow mesenchymal stem cells (BMMSC) for the treatment of tendon and ligament injuries in the horse suggest improved outcome measures in both experimental and clinical studies. Although the BMMSC are implanted into the tendon lesion in large numbers (usually 10 - 20 million cells), only a relatively small number survive (<10%) although these can persist for up to 5 months after implantation. This appears to be a common observation in other species where BMMSC have been implanted into other tissues and it is important to understand when this loss occurs, how many survive the initial implantation process and whether the cells are cleared into other organs. Tracking the fate of the cells can be achieved by radiolabeling the BMMSC prior to implantation which allows non-invasive in vivo imaging of cell location and quantification of cell numbers. This protocol describes a cell labeling procedure that uses Technetium-99m (Tc-99m), and tracking of these cells following implantation into injured flexor tendons in horses. Tc-99m is a short-lived (t1/2 of 6.01 hr) isotope that emits gamma rays and can be internalized by cells in the presence of the lipophilic compound hexamethylpropyleneamine oxime (HMPAO). These properties make it ideal for use in nuclear medicine clinics for the diagnosis of many different diseases. The fate of the labeled cells can be followed in the short term (up to 36 hr) by gamma scintigraphy to quantify both the number of cells retained in the lesion and distribution of the cells into lungs, thyroid and other organs. This technique is adapted from the labeling of blood leukocytes and could be utilized to image implanted BMMSC in other organs. PMID:26709915

  5. Influence of exercise on the distribution of technetium Tc 99m medronate following intra-articular injection in horses.

    PubMed

    Dulin, Jennifer A; Drost, W Tod; Phelps, Mitch A; Santschi, Elizabeth M; Menendez, Maria I; Bertone, Alicia L

    2012-03-01

    To determine the effects of exercise on the distribution and pharmacokinetics of technetium Tc 99m medronate ((99m)Tc-MDP) following intra-articular (IA) injection in horses. 5 horses. 1 antebrachiocarpal joint (ACJ)/horse was assigned to the exercised group (n = 5), and the contralateral ACJ was evaluated in the nonexercised group (5) after a minimum washout period of 7 days. Following IA injection of (99m)Tc-MDP (148 MBq), blood and scintigraphic images of the carpus were obtained at 5, 10, 15, 20, 25, 30, 45, 60, 90, 120, 240, 360, 480, 600, 720, and 1,440 minutes. Plasma and scintigraphic radioactivity were determined over time, and pharmacokinetic parameters were generated via noncompartmental and compartmental analyses. Each horse was monitored via physical and lameness examination and ACJ synovial fluid analysis before injection and at days 1, 2, 3, and 7. Lameness was not observed. Mean ± SD synovial fluid WBC count increased at day 1 (exercised, 721 ± 234 cells/μL; nonexercised, 948 ± 223 cells/μL), but returned to baseline at days 3 and 7 Mean time to maximum plasma radioactivity was earlier in the exercised group (16.00 ± 2.35 minutes) than the nonexercised group (43.75 ± 3.64 minutes). Linear regression of the scintigraphic radioactivity-time curves revealed a greater negative slope in the exercised group within the first 25 minutes. There was no difference in absorption or elimination rate constants in a 2-compartment model. IA injection of (99m)Tc-MDP was safe and effective for evaluating synovial solute distribution. Exercise significantly increased early transfer of (99m)Tc-MDP from the ACJ into plasma, although absorption and elimination rate constants were not affected. Exercise may affect synovial clearance and withdrawal times of medications administered IA.

  6. Technetium-99 and strontium-90: Abundance determination at ultratrace sensitivity by AMS as signatures of undeclared nuclear reprocessing activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McAninch, J.E.; Proctor, I.D.

    1995-03-01

    The purpose of this White Paper is to examine the use of the ultratrace technique Accelerator Mass Spectrometry (AMS) to lower detection limits for {sup 99}Tc and {sup 90}Sr, and to examine the utility of these isotopes as signatures of a convert reprocessing facility. The International Atomic Energy Agency (IAEA) has committed to improving the effectiveness of the IAEA Safeguards System. This is in some degree a result of the discovery in 1991 of an undeclared Iraqi EMIS program. Recommendations from the March 1993 Consultants Group Meeting have resulted in several studies and follow on field trials to identify environmentalmore » signatures from covert nuclear fuel reprocessing activity. In particular, the April, 1993 reports of the Standing Advisory Group on Safeguards Implementation (SAGSI) identified the long-lived radioisotopes Technetium-99 and strontium-90 as two reliable signatures of fuel reprocessing activity. This report also suggested pathways in the chemical processing of irradiated fuel where these elements would be volatilized and potentially released in amounts detectable with ultratrace sensitivity techniques. Based on measured {sup 99}Tc background levels compiled from a variety of sources, it is estimated that AMS can provide 10% measurements of environmental levels of {sup 99}Tc in a few minutes using modestly sized samples: a few grams for soils, plants, or animal tissues; one to several liters for rain or seawater samples; and tens to hundreds of cubic meters for air sampling. Small sample sizes and high sample throughput result in significant increases in feasibility, cost effectiveness, and quality of data for a regional monitoring program. Similar results are expected for {sup 90}Sr.« less

  7. Retrograde spread of 5-aminosalicylic acid enemas in patients with active ulcerative colitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Campieri, M.; Lanfranchi, G.A.; Brignola, C.

    1986-02-01

    In an attempt to know the exact retrograde spread of high-dosage 5-aminosalicylic acid enemas, we have studied eight patients with active left-sided colitis, by adding a small amount of barium sulfate to the enemas and by checking the spread radiologically after 15 minutes, 1 hour, and 6 hours. Four grams of 5-aminosalicylic acid in 100-ml enemas and 4 gm in 200-ml enemas were used. The same experiment was repeated in a subsequent attack, with enemas labeled with technetium-99m and checked by scintiscans in five of these patients. We always have observed a volume-dependent spread of enemas but, interestingly, in themore » patients studied with technetium-99m there was always a wider spread than that which was detected with barium enemas. In all five patients, 100-ml enemas reached the splenic flexure. In two patients with total colitis, a progression of 100-ml technetium-99m enemas was performed in the transverse colon, but the maximum opacity remained in the left side. We can conclude that 4 gm of 5-aminosalicylic acid in 100-ml enemas can be suitable for treating patients with left-sided colitis, and will represent a valid addition for patients with more extensive colitis.« less

  8. Additives

    NASA Technical Reports Server (NTRS)

    Smalheer, C. V.

    1973-01-01

    The chemistry of lubricant additives is discussed to show what the additives are chemically and what functions they perform in the lubrication of various kinds of equipment. Current theories regarding the mode of action of lubricant additives are presented. The additive groups discussed include the following: (1) detergents and dispersants, (2) corrosion inhibitors, (3) antioxidants, (4) viscosity index improvers, (5) pour point depressants, and (6) antifouling agents.

  9. LABORATORY REPORT ON THE REMOVAL OF PERTECHNETATE FROM TANK 241-AN-105 SIMULANT USING PUROLITE A530E

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DUNCAN JB; HAGERTY KJ, MOORE WP; JOHNSON JM

    2012-04-17

    This report documents the laboratory testing and analyses as directed under the test plan, LAB-PLN-11-00010, Evaluation of Technetium Ion Exchange Material against Hanford Double Shell Tank Supernate Simulate with Pertechnetate. Technetium (Tc-99) is a major fission product from nuclear reactors, and because it has few applications outside of scientific research, most of the technetium will ultimately be disposed of as nuclear waste. The radioactive decay of Tc-99 to ruthenium 99 (Ru-99) produces a low energy {beta}{sup -} particle (0.1 MeV max). However, due to its fairly long half-life (t{sub 1/2} = 2.13E05 years), Tc-99 is a major source of radiationmore » in low-level waste (UCRL-JRNL-212334, Current Status of the Thermodynamic Data for Technetium and its Compounds and Aqueous Species). Technetium forms the soluble oxy anion, TcO{sub 4}{sup -} under aerobic conditions. This anion is very mobile in groundwater and poses a health risk (ANL, Radiological and Chemical Fact Sheets to Support Health Risk Analyses for Contaminated Areas). It has been demonstrated that Purolite{reg_sign} A530E is highly effective in removing TcO{sub 4}{sup -} from a water matrix (RPP-RPT-23199, The Removal of Technetium-99 from the Effluent Treatment Facility Basin 44 Waste Using Purolite A-530E, Reillex HPQ, and Sybron IONAC SR-7 Ion Exchange Resins). Purolite{reg_sign} A530E is the commercial product of the Oak Ridge National Laboratory's Biquat{trademark} resin (Gu, B. et. ai, Development of Novel Bifunctional Anion-Exchange Resins with Improved Selectivity for Pertechnetate Sorption from Contaminated Groundwater). Further work has demonstrated that technetium-loaded A530E achieves a leachability index in Cast Stone of 12.5 (ANSI/ASN-16.1-2003, Measurement of the Leachability of Solidified Low-Level Radioactive Wastes by a Short-term Test Procedure) as reported in RPP-RPT-39195, Assessment of Technetium Leachability in Cement-Stabilized Basin 43 Groundwater Brine. This effort

  10. Thermodynamic and Microstructural Mechanisms in the Corrosion of Advanced Ceramic Tc-bearing Waste Forms and Thermophysical Properties

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hartmann, Thomas

    Technetium-99 (Tc, t 1/2 = 2.13x10 5 years) is a challenge from a nuclear waste perspective and is one of the most abundant, long-lived radioisotopes found in used nuclear fuel (UNF). Within the Hanford Tank Waste Treatment and Immobilization Plant, technetium volatilizes at typical glass melting temperature, is captured in the off-gas treatment system and recycled back into the feed to eventually increase Tc-loadings of the glass. The aim of this NEUP project was to provide an alternative strategy to immobilize fission technetium as durable ceramic waste form and also to avoid the accumulation of volatile technetium within the offmore » gas melter system in the course of vitrifying radioactive effluents in a ceramic melter. During this project our major attention was turned to the fabrication of chemical durable mineral phases where technetium is structurally bond entirely as tetravalent cation. These mineral phases will act as the primary waste form with optimal waste loading and superior resistance against leaching and corrosion. We have been very successful in fabricating phase-pure micro-gram amounts of lanthanide-technetium pyrochlores by dry-chemical synthesis. However, upscaling to a gram-size synthesis route using either dry- or wet-chemical processing was not always successful, but progress can be reported on a variety of aspects. During the course of this 5-year NEUP project (including a 2-year no-cost extension) we have significantly enhanced the existing knowledge on the fabrication and properties of ceramic technetium waste forms.« less

  11. Significance of Technetium-99m Human Serum Albumin Diethylenetriamine Pentaacetic Acid Scintigraphy in Patients with Nephrotic Syndrome

    PubMed Central

    Takashima, Tsuyoshi; Kishi, Tomoya; Onozawa, Koji; Rikitake, Shuichi; Miyazono, Motoaki; Otsuka, Takateru; Irie, Hiroyuki; Iwakiri, Ryuichi; Fujimoto, Kazuma; Ikeda, Yuji

    2015-01-01

    It is thought that a large amount of albumin leaking from the glomerulus in nephrotic syndrome (NS) is reabsorbed at the proximal tubule and catabolized. Therefore, it is possible the final quantity of urinary protein does not always reflect the amount of leakage of protein from the glomerulus. We experienced two cases without nephrotic range proteinuria thought to involve hypoproteinemia due to the same pathophysiology as NS. On these patients, we performed protein leakage scintigraphy with technetium-99m human serum albumin diethylenetriamine pentaacetic acid (99mTc-HSAD) to exclude a diagnosis of protein-losing gastroenteropathy and observed diffuse positive accumulation in the kidneys with more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration. In healthy adults intravenously given 99mTc-HSAD, the same dynamics are observed as in albumin metabolism, and the organ radioactivity of the liver and kidneys after 24 hours is equal. Therefore, we thought it was possible that the renal uptake 24 hours after 99mTc-HSAD administration was a characteristic finding of NS. In order to confirm it, the subjects were divided into two groups: the NS group (n = 10) and the non-NS group (n = 7). We defined more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration as Dense Kidney (+). Furthermore, we designed regions of interest in the right and left kidneys and liver on anterior and posterior images, then calculated the kidney-liver ratio. Nine of the ten patients had Dense Kidney (+) in the NS group, compared to none in the non-NS group. And the kidney-liver ratio was significantly higher in the NS group than in the non-NS group on each view in the bilateral kidneys. In conclusion, our results suggest that the renal uptake 24 hours after 99mTc-HSAD administration is a characteristic finding of NS. PMID:25859658

  12. Significance of technetium-99m human serum albumin diethylenetriamine pentaacetic acid scintigraphy in patients with nephrotic syndrome.

    PubMed

    Takashima, Tsuyoshi; Kishi, Tomoya; Onozawa, Koji; Rikitake, Shuichi; Miyazono, Motoaki; Otsuka, Takateru; Irie, Hiroyuki; Iwakiri, Ryuichi; Fujimoto, Kazuma; Ikeda, Yuji

    2015-01-01

    It is thought that a large amount of albumin leaking from the glomerulus in nephrotic syndrome (NS) is reabsorbed at the proximal tubule and catabolized. Therefore, it is possible the final quantity of urinary protein does not always reflect the amount of leakage of protein from the glomerulus. We experienced two cases without nephrotic range proteinuria thought to involve hypoproteinemia due to the same pathophysiology as NS. On these patients, we performed protein leakage scintigraphy with technetium-99m human serum albumin diethylenetriamine pentaacetic acid (99mTc-HSAD) to exclude a diagnosis of protein-losing gastroenteropathy and observed diffuse positive accumulation in the kidneys with more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration. In healthy adults intravenously given 99mTc-HSAD, the same dynamics are observed as in albumin metabolism, and the organ radioactivity of the liver and kidneys after 24 hours is equal. Therefore, we thought it was possible that the renal uptake 24 hours after 99mTc-HSAD administration was a characteristic finding of NS. In order to confirm it, the subjects were divided into two groups: the NS group (n = 10) and the non-NS group (n = 7). We defined more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration as Dense Kidney (+). Furthermore, we designed regions of interest in the right and left kidneys and liver on anterior and posterior images, then calculated the kidney-liver ratio. Nine of the ten patients had Dense Kidney (+) in the NS group, compared to none in the non-NS group. And the kidney-liver ratio was significantly higher in the NS group than in the non-NS group on each view in the bilateral kidneys. In conclusion, our results suggest that the renal uptake 24 hours after 99mTc-HSAD administration is a characteristic finding of NS.

  13. An estimate of the inventory of technetium-99 in the sub-tidal sediments of the Irish Sea.

    PubMed

    Jenkinson, Stuart B; McCubbin, David; Kennedy, Paul H W; Dewar, Alastair; Bonfield, Rachel; Leonard, Kinson S

    2014-07-01

    Published results from earlier studies have provided indications that measurable quantities of technetium-99 ((99)Tc) have accumulated in the sub-tidal sediments of the Irish Sea. This is due to the enhanced discharges from the Sellafield nuclear reprocessing plant in Cumbria, UK (between 1994 and 2004). Depth distributions of (99)Tc concentrations in sub-tidal sediments have been determined from a limited number of Irish Sea sites, following the collection of deep sediment cores (up to 2 m in depth), sampled in two research cruise surveys in 2005 and 2006. Vertical concentration profiles of (99)Tc from a range of substrates in the Irish Sea are presented here and these have been used to produce an estimate of the total inventory of (99)Tc residing in the sub-tidal sediments of the Irish Sea. Significant variation was observed between (99)Tc concentrations in the sediment samples, as well as in the shape of individual depth profiles. As anticipated, concentrations tended to be greater on fine-grained (muddy) substrates and showed a general decrease with distance from Sellafield. Vertical concentration profiles of (137)Cs, and (137)Cs data from published work, have also been considered to evaluate the use of the relatively few (99)Tc core data (upon which to determine the (99)Tc inventory). The inventories of (99)Tc and (137)Cs are estimated to have been of the order of 30 and 455 terabecquerels (TBq), respectively, or ∼2% of the total cumulative Sellafield discharge for each of the two radionuclides. The residence half-time of (137)Cs in the sub-tidal sediments of the Irish Sea is estimated to be in the order of ∼16 years. Therefore, as the Kd values for (99)Tc and (137)Cs are similar, this also provides an indicative value to predict future losses of (99)Tc from the sediment reservoir. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  14. Liver Function Assessment Using Technetium 99m-Galactosyl Single-Photon Emission Computed Tomography/CT Fusion Imaging: A Prospective Trial.

    PubMed

    Okabayashi, Takehiro; Shima, Yasuo; Morita, Sojiro; Shimada, Yasuhiro; Sumiyoshi, Tatsuaki; Sui, Kenta; Iwata, Jun; Iiyama, Tatsuo

    2017-12-01

    The prediction of postoperative liver function remains a largely subjective practice based on CT volumetric analysis. However, future liver volume after a hepatectomy is not the only factor that contributes to postoperative liver function and outcomes. In this prospective trial, 185 consecutive patients who underwent liver operations between 2014 and 2015 were studied. Volumetric and functional rates of remnant liver were measured using technetium 99m-galactosyl human serum albumin single-photon emission computed tomography/CT fusion imaging to evaluate post-hepatectomy remnant liver function. Remnant indocyanine green clearance rate using galactosyl (KGSA) (KGSA × functional rate) was used to predict future remnant liver function. Hepatectomy was considered safe for patients with remnant KGSA values ≥0.05, and the primary end point was to determine the accuracy and reliability of this criteria. The prediction of the 90-day major complication and mortality rates was assessed. Median hospital stay was 9 days and median ICU stay was 1 day, with only 1 in-hospital death (90-day mortality rate 0.5%). Overall morbidity rate evaluated according to the Clavien-Dindo classification was 9%. For post-hepatectomy liver failure definitions, the International Study Group of Liver Surgery definition was fulfilled in 14 patients (8%), with the majority being grade B (50%), compared with 2 patients (1%) fulfilling the "50-50" criteria, and 0 patients (0%) fulfilling the Peak Bili >7 criteria. Results of this study showed that remnant KGSA provided information that allowed us to predict remnant liver function. This information will be important for surgeons when deciding on a treatment plan for patients with liver diseases. (ClinicalTrials.gov ID: NCT02013895). Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  15. Positioning irrigation of contrast cystography for diagnosis of occult vesicoureteric reflux: association with technetium-99m dimercaptosuccinic acid scans.

    PubMed

    Berger, Christoph; Becker, Tanja; Koen, Mark; Zeino, Mazen; Fitz, Friedrich; Beheshti, Mohsen; Wolf-Kohlmeier, Iris; Haim, Silke; Riccabona, Marcus

    2013-12-01

    Positioning irrigation of contrast (PIC) cystography identifies occult or PIC vesicoureteral reflux (PIC-VUR) in children with recurrent febrile urinary tract infections (UTI) but no vesicoureteric reflux (VUR) on standard voiding cystourethrogram (VCUG). We sought to identify the relationship between PIC-VUR and renal scarring in technetium-99m dimercaptosuccinic acid (DMSA) scans. We retrospectively analysed PIC cystograms and DMSA scans for 154 kidneys in 81 children (65 girls; 16 boys; median age, 4.7 years; range, 0.9-15.2). Renal scarring was graded on a scale of 0-3. DMSA scans were pathologic in 66 patients (81%). Children had experienced mean 3.8 febrile UTI (range 1-25). Forty-seven (58%) children had a history of reflux, including 15 (19%) with previous anti-reflux operations. Indications for PIC cystography were recurrence of febrile UTI after either bilateral negative VCUG (66 children) or unilateral VUR (15 children) with contralateral/bilateral scarring or reflux that had changed sides in subsequent VCUGs. PIC-VUR was bilateral in 63, unilateral in 12, and absent in 6 children. Statistically significant associations between PIC-VUR grade and severity of renal scarring were identified in inter-individual (n = 77, p = 0.017) and intra-individual (refluxing vs. nonrefluxing kidney; n = 12, p = 0.008) analyses. After excluding patients with history of VUR, statistical significance was maintained in inter-individual analysis (n = 49; p = 0.018). The data suggest an association between PIC-VUR and severity of renal scarring, and legitimise the use of PIC cystography in children with renal scarring due to recurrent febrile UTI but negative findings on VCUG. Copyright © 2012 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  16. Assessment of the value of quantitative thyroid scintigraphy for determination of thyroid function in dogs.

    PubMed

    Shiel, R E; Pinilla, M; McAllister, H; Mooney, C T

    2012-05-01

    To assess the value of thyroid scintigraphy to determine thyroid status in dogs with hypothyroidism and various non-thyroidal illnesses. Thyroid hormone concentrations were measured and quantitative thyroid scintigraphy performed in 21 dogs with clinical and/or clinicopathological features consistent with hypothyroidism. In 14 dogs with technetium thyroidal uptake values consistent with euthyroidism, further investigations supported non-thyroidal illness. In five dogs with technetium thyroidal uptake values within the hypothyroid range, primary hypothyroidism was confirmed as the only disease in four. The remaining dog had pituitary-dependent hyperadrenocorticism. Two dogs had technetium thyroidal uptake values in the non-diagnostic range. One dog had iodothyronine concentrations indicative of euthyroidism. In the other, a dog receiving glucocorticoid therapy, all iodothyronine concentrations were decreased. Markedly asymmetric technetium thyroidal uptake was present in two dogs. All iodothyronine concentrations were within reference interval but canine thyroid stimulating hormone concentration was elevated in one. Non-thyroidal illness was identified in both cases. In dogs, technetium thyroidal uptake is a useful test to determine thyroid function. However, values may be non-diagnostic, asymmetric uptake can occur and excess glucocorticoids may variably suppress technetium thyroidal uptake and/or thyroid hormone concentrations. Further studies are necessary to evaluate quantitative thyroid scintigraphy as a gold standard method for determining canine thyroid function. © 2012 British Small Animal Veterinary Association.

  17. Method of tagging excipients with /sup 99m/Tc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardy, A.; Beydon, J.; Gobin, R.

    1977-11-08

    A method of using /sup 99m/technetium for tagging excipients in medical diagnosis by scintigraphy comprises mixing, in an aqueous solution of alkali-metal pertechnetate, an excipient and a reducing agent in the form of a complex, which complex is such that the association constant of the anion with reduced techetium is less than the association constant of the excipient with reduced technetium, thereby forming a radio-pharmaceutical substance which is a complex between the excipient and /sup 99m/technetium.

  18. TC-99 Decontaminant from heat treated gaseous diffusion membrane -Phase I, Part B

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L.; Restivo, M.; Duignan, M.

    2017-11-01

    Uranium gaseous diffusion cascades represent a significant environmental challenge to dismantle, containerize and dispose as low-level radioactive waste. Baseline technologies rely on manual manipulations involving direct access to technetium-contaminated piping and materials. There is a potential to utilize novel decontamination technologies to remove the technetium and allow for on-site disposal of the very large uranium converters. Technetium entered these gaseous diffusion cascades as a hexafluoride complex in the same fashion as uranium. Technetium, as the isotope Tc-99, is an impurity that follows uranium in the first cycle of the Plutonium and Uranium Extraction (PUREX) process. The technetium speciation or exactmore » form in the gaseous diffusion cascades is not well defined. Several forms of Tc-99 compounds, mostly the fluorinated technetium compounds with varying degrees of volatility have been speculated by the scientific community to be present in these cascades. Therefore, there may be a possibility of using thermal or leaching desorption, which is independent of the technetium oxidation states, to perform an insitu removal of the technetium as a volatile species and trap the radionuclide on sorbent traps which could be disposed as low-level waste. Based on the positive results of the first part of this work1 the use of steam as a thermal decontamination agent was further explored with a second piece of used barrier material from a different location. This new series of tests included exposing more of the material surface to the flow of high temperature steam through the change in the reactor design, subjecting it to alternating periods of stream and vacuum, as well as determining if a lower temperature steam, i.e., 121°C (250°F) would be effective, too. Along with these methods, one other simpler method involving the leaching of the Tc-99 contaminated barrier material with a 1.0 M aqueous solution of ammonium carbonate, with and without

  19. p-Tertbutylcalix[4]arene nanoemulsion: preparation, characterization and comparative evaluation of its decontamination efficacy against Technetium-99m, Iodine-131 and Thallium-201.

    PubMed

    Rana, Sudha; Sharma, Navneet; Ojha, Himanshu; Shivkumar, Hosakote Gurumalappa; Sultana, Sarwat; Sharma, Rakesh Kumar

    2014-05-01

    This study aimed to develop p-tertbutylcalix[4]arene o/w nanoemulsion for decontamination of radioisotopes from skin. Formulation was characterized using dynamic light scattering (DLS), transmission electron microscopy (TEM), multi-photon confocal microscopy techniques and in vitro dissolution studies. In vivo evaluation of nano-emulsion was done using nuclear medicine technique. Stability studies and dermal toxicity studies were also carried out. Comparative decontamination efficacy (DE) studies were performed on synthetic human tissue equivalent material and Sprague Dawley rat against three commonly used medical radioisotopes, i.e., Technetium-99m ((99m)Tc), Iodine-131 ((131)I) and Thallium-201 ((201)Tl). Decontamination was performed using cotton swabs soaked in nanoemulsion at different time intervals of contaminants exposure. Whole body imaging and static counts were recorded using gamma camera before and after each decontamination attempt data was analyzed using one way analysis of variance (ANOVA) and found to be statistically significant (p<0.05). DE of the nanoemulsion loaded with p-tertbutylcalix[4]arene was observed to be 88±5%, 90±3% and 89±3% for (99m)Tc, (131)I and (201)Tl respectively. Dermal toxicity studies revealed no significant differences between treated and control animals. Skin histopathology slides with and without API (Active pharmaceutical ingredients) also found to be comparable. p-Tertbutylcalix[4]arene loaded nanoemulsion shows great promise for skin decontamination against broad ranges of radiological contaminants besides being stable and safe. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Sectorial technetium-99m-dimercaptosuccinic acid scintigraphy for monitoring the effect of extracorporeal piezoelectric lithotripsy for calyceal calculi on regional renal function.

    PubMed

    Al-Tawheed, A; Al-Awadi, K A; Kehinde, E O; Loutfi, I; Abdul-Haleem, H; Al-Mohannadi, S

    2003-01-01

    To apply a semiquantitative method for analysis of technetium-99m-dimercaptosuccinic acid ((99m)Tc-DMSA) renal scintigraphy for monitoring the effect of extracorporeal piezoelectric lithotripsy (EPL) in patients with calyceal stones on regional kidney function and to check whether EPL had caused any deleterious effect on the target calyceal renal parenchymal function. Forty patients (mean age 35 years) suffering from calyceal stones documented by abdominal plain radiography, intravenous urogram or abdominal ultrasound were studied. All patients were treated by EPL. (99m)Tc-DMSA scan was performed before and 4 weeks after EPL. Sector analysis involved calculation of the relative function of the target calyx to the function of the ipsilateral kidney and the relative function of the treated kidney to global renal function. The stone sizes were 6-11 mm in diameter and 11 were located in the upper, 13 in the middle and 16 in the lower calyx. After EPL, the overall stone clearance rate was 85% (100% for calculi in the upper and middle calyces, 62% for lower calyces). The sector analysis did not show statistically significant change of the relative regional (calyceal) or whole kidney function between the pre- and post-EPL (99m)Tc-DMSA scans. Using sector analysis, EPL appeared to be a safe modality and its usage was not associated with any untoward effect on calyceal or whole kidney function. Sector analysis of (99m)Tc-DMSA renal scan is a simple semiquantitative method for monitoring regional changes of kidney function after EPL for treatment of calyceal stone. Copyright 2003 S. Karger AG, Basel

  1. Multicenter Trial of Sentinel Node Biopsy for Breast Cancer Using Both Technetium Sulfur Colloid and Isosulfan Blue Dye

    PubMed Central

    Tafra, Lorraine; Lannin, Donald R.; Swanson, Melvin S.; Van Eyk, Jason J.; Verbanac, Kathryn M.; Chua, Arlene N.; Ng, Peter C.; Edwards, Maxine S.; Halliday, Bradford E.; Henry, C. Alan; Sommers, Linda M.; Carman, Claire M.; Molin, Melinda R.; Yurko, John E.; Perry, Roger R.; Williams, Robert

    2001-01-01

    Objective To determine the factors associated with false-negative results on sentinel node biopsy and sentinel node localization (identification rate) in patients with breast cancer enrolled in a multicenter trial using a combination technique of isosulfan blue with technetium sulfur colloid (Tc99). Summary Background Data Sentinel node biopsy is a diagnostic test used to detect breast cancer metastases. To test the reliability of this method, a complete lymph node dissection must be performed to determine the false-negative rate. Single-institution series have reported excellent results, although one multicenter trial reported a false-negative rate as high as 29% using radioisotope alone. A multicenter trial was initiated to test combined use of Tc99 and isosulfan blue. Methods Investigators (both private-practice and academic surgeons) were recruited after attending a course on the technique of sentinel node biopsy. No investigator participated in a learning trial before entering patients. Tc99 and isosulfan blue were injected into the peritumoral region. Results Five hundred twenty-nine patients underwent 535 sentinel node biopsy procedures for an overall identification rate in finding a sentinel node of 87% and a false-negative rate of 13%. The identification rate increased and the false-negative rate decreased to 90% and 4.3%, respectively, after investigators had performed more than 30 cases. Univariate analysis of tumor showed the poorest success rate with older patients and inexperienced surgeons. Multivariate analysis identified both age and experience as independent predictors of failure. However, with older patients, inexperienced surgeons, and patients with five or more metastatic axillary nodes, the false-negative rate was consistently greater. Conclusions This multicenter trial, from both private practice and academic institutions, is an excellent indicator of the general utility of sentinel node biopsy. It establishes the factors that play an

  2. Studies on focal alveolar bone healing with technetium (Tc)-99m labeled methylene diphosphonate and gold-collimated cadmium telluride probe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsuchimochi, M.; Hosain, F.; Engelke, W.

    1991-01-01

    The benefit of using a collimator for a miniaturized cadmium telluride probe was evaluated by monitoring the bone-healing processes for 13 weeks after the induction of small iatrogenic alveolar bone lesions in one side of the mandible in beagles. Technetium (Tc)-99m labeled methylene diphosphonate (200 to 300 MBq, 5.1 to 8.1 mCi, in a solution of 0.5 to 1 ml, intravenously) was used as a bone-seeking radiopharmaceutical. The radioactivity over the bone lesion (L) and the contralateral normal site (C) in the mandible were measured between 1.5 and 2 hours after injection of the tracer, and the activity ratio L/Cmore » served as an index of relative bone uptake. A study of six dogs revealed that the healing response to a hemispheric bone defect of 2 mm diameter in the cortical bone could not be detected by an uncollimated probe, and in a repeated study in two dogs the use of a gold collimator (5 mm in diameter, 5 mm in length) did not increase the L/C ratio significantly. A second study in six dogs with 5 mm lesions showed that although systematic trends in the time courses of the L/C ratio obtained both with and without the collimator could be demonstrated, the L/C ratio of collimated versus uncollimated measurements was significantly (p less than 0.005) increased. In three of the latter six dogs, abscesses developed after 9 weeks, leading to a second increase (p less than 0.05) of the L/C ratio with collimation compared with the noninflammation group; without collimation no significant (p greater than 0.15) difference between the two groups could be demonstrated.« less

  3. Radioactive excretion in human milk following administration of /sup 99m/Tc macroaggregated albumin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pittard, W.B.; Merkatz, R.; Fletcher, B.D.

    Albumin-tagged sodium pertechnetate (technetium) is routinely used in nuclear medicine for scanning procedures of the lung. The rate of excretion of this radionuclide into breast milk and the resultant potential radiation hazard to the nursing infant have received little attention. Therefore the milk from a nursing mother who required a lung scan because of suspected pulmonary emboli using an intravenous injection of 4 mCi of /sup 99m/Tc macroaggregated human serum albumin was monitored. Albumin tagging severely limited the entrance of technetium into her milk and the radioactivity of the milk returned to base line by 24 hours. A total ofmore » 2.02 muCi of technetium was measured in the 24-hour milk collection after technetium injection and 94% of this amount was excreted by 15.5 hours. This amount of technetium administered orally to a newborn would deliver a total body radiation dose of .3 mrad. Therefore, an infant would receive trivial doses of radiation if breast-feeding were resumed 15.5 hours after administration of the radionuclide to the mother and nursing can clearly be resumed safely 24 hours after injection.« less

  4. Screening for Hepatopulmonary Syndrome in Cirrhotic Patients Using Technetium 99m-macroaggregated Albumin Perfusion Lung Scan (Tc-MAA): Diagnostic Approach and Clinical Correlations.

    PubMed

    Fragaki, Maria; Sifaki-Pistolla, Dimitra; Samonakis, Dimitrios N; Koulentaki, Mairi; Koukouraki, Sofia; Stathaki, Maria; Kouroumalis, Elias

    2017-09-28

    The aims of this study were to prospectively screen cirrhotic patients with arterial blood gas test and albumin perfusion scan, identify those fulfilling the classic hepatopulmonary syndrome (HPS) criteria, correlate with clinical parameters, and evaluate the survival of patients with HPS compared with those without HPS in a genetically homogenous Cretan cirrhotic population. Data on consecutive 102 patients within 1 year were collected and analyzed. All patients underwent a technetium 99m-macroaggregated albumin perfusion lung scan (Tc-MAA). Diagnosis of HPS was based on the presence of the quantitative index Tc-MAA≥6% and a [P(A-a)O2]≥15 mm Hg (≥20 mm Hg for patients over >64 y). In 94/102 patients, complete scintigraphic data were available. In total, 24 (26%) patients fulfilled the diagnostic criteria of HPS; 95.8% of them had mild-to-moderate HPS. In 8 patients the Tc-MAA scintigraphy could not be interpreted. There was no difference in HPS between decompensated (24.6%) and compensated cirrhosis (27.3%). In the multivariate analysis only the quantitative index was significant for the diagnosis of HPS (P=0.001, odds ratio; 95% confidence interval, 7.05; 2.27-21.87). Kaplan- Meier survival curves indicated a similar overall prognosis for patients diagnosed with HPS (P=0.105). HPS is a frequent complication of cirrhosis. Mild-to-moderate HPS has no significant effect on survival of cirrhotic patients. The quantitative Tc-MAA test is a reliable tool for diagnosis.

  5. Food additives

    PubMed Central

    Spencer, Michael

    1974-01-01

    Food additives are discussed from the food technology point of view. The reasons for their use are summarized: (1) to protect food from chemical and microbiological attack; (2) to even out seasonal supplies; (3) to improve their eating quality; (4) to improve their nutritional value. The various types of food additives are considered, e.g. colours, flavours, emulsifiers, bread and flour additives, preservatives, and nutritional additives. The paper concludes with consideration of those circumstances in which the use of additives is (a) justified and (b) unjustified. PMID:4467857

  6. Evaluation of the biliary and brain distribution of technetium Tc 99m sestamibi in healthy dogs with the ABCB1 wildtype genotype before and after treatment with spinosad.

    PubMed

    MacKay, Christopher S; Mattoon, John S; Roberts, Gregory D; Tucker, Russell L; Morimoto, Trevor R; Mealey, Katrina L

    2012-06-01

    To determine whether the reported drug-drug interaction between the flea medication spinosad and ivermectin is attributable to inhibition of P-glycoprotein by spinosad. 6 healthy adult dogs with the ABCB1 wildtype genotype. The study was conducted as a prospective, masked, randomized crossover design. Six dogs were allocated to 2 groups; each dog served as its own control animal. Dogs in one of the groups received spinosad at the manufacturer's recommended dose; the other group received no treatment. Forty-eight hours later, scintigraphic imaging of the head and abdomen were performed with the radiolabeled P-glycoprotein substrate methoxy-isobutyl-isonitrile (sestamibi) in both groups of dogs. After a washout period of 60 days, the dogs in each group received the alternate treatment, and scintigraphic imaging again was performed 48 hours later. Gallbladder-to-liver and brain-to-neck musculature ratios of technetium Tc 99m sestamibi were calculated for each dog and compared between treatments. No significant differences in gallbladder-to-liver or brain-to-neck musculature ratios were found between treatments. Results provided evidence that spinosad did not inhibit P-glycoprotein function 48 hours after spinosad was administered at the manufacturer's recommended dose. Further investigations will be necessary to elucidate the mechanism of the reported toxic interaction between spinosad and ivermectin.

  7. In Situ Quantification of [Re(CO)3]+ by Fluorescence Spectroscopy in Simulated Hanford Tank Waste.

    PubMed

    Branch, Shirmir D; French, Amanda D; Lines, Amanda M; Rapko, Brian M; Heineman, William R; Bryan, Samuel A

    2018-02-06

    A pretreatment protocol is presented that allows for the quantitative conversion and subsequent in situ spectroscopic analysis of [Re(CO) 3 ] + species in simulated Hanford tank waste. In this test case, the nonradioactive metal rhenium is substituted for technetium (Tc-99), a weak beta emitter, to demonstrate proof of concept for a method to measure a nonpertechnetate form of technetium in Hanford tank waste. The protocol encompasses adding a simulated waste sample containing the nonemissive [Re(CO) 3 ] + species to a developer solution that enables the rapid, quantitative conversion of the nonemissive species to a luminescent species which can then be detected spectroscopically. The [Re(CO) 3 ] + species concentration in an alkaline, simulated Hanford tank waste supernatant can be quantified by the standard addition method. In a test case, the [Re(CO) 3 ] + species was measured to be at a concentration of 38.9 μM, which was a difference of 2.01% from the actual concentration of 39.7 μM.

  8. Materials for Tc Capture to Increase Tc Retention in Glass Waste Form

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Hrma, Pavel R.; Kruger, Albert A.

    99Technetium is a long-lived fission product found in the tank waste at the Hanford site in Washington State. In its heptavalent species, it is volatile at the temperatures used in Hanford Tank Waste Treatment and Immobilization Plant vitrification melters, and thus is challenging to incorporate into waste glass. In order to decrease volatility and thereby increase retention, technetium can be converted into more thermally stable species. Several mineral phases, such as spinel, are able to incorporate tetravalent technetium in a chemically durable and thermally stable lattice, and these hosts may promote the decreased volatility that is desired. In order tomore » be usefully implemented, there must be a synthetic rout to these phases that is compatible with both technetium chemistry and current Hanford Tank Waste Treatment and Immobilization Plant design. Synthetic routes for spinel and other potential host phases are examined.« less

  9. Postoperative myocardial infarction documented by technetium pyrophosphate scan using single-photon emission computed tomography: Significance of intraoperative myocardial ischemia and hemodynamic control

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheng, D.C.; Chung, F.; Burns, R.J.

    The aim of this prospective study was to document postoperative myocardial infarction (PMI) by technetium pyrophosphate scan using single-photon emission computed tomography (TcPPi-SPECT) in 28 patients undergoing elective coronary bypass grafting (CABG). The relationships of intraoperative electrocardiographic myocardial ischemia, hemodynamic responses, and pharmacological requirements to this incidence of PMI were correlated. Radionuclide cardioangiography and TcPPi-SPECT were performed 24 h preoperatively and 48 h postoperatively. A standard high-dose fentanyl anesthetic protocol was used. Twenty-five percent of elective CABG patients were complicated with PMI, as documented by TcPPi-SPECT with an infarcted mass of 38.0 +/- 5.5 g. No significant difference in demographic,more » preoperative right and left ventricular function, number of coronary vessels grafted, or aortic cross-clamp time was observed between the PMI and non-PMI groups. The distribution of patients using preoperative beta-adrenergic blocking drugs or calcium channel blocking drugs was found to have no correlation with the outcome of PMI. As well, no significant differences in hemodynamic changes or pharmacological requirements were observed in the PMI and non-PMI groups during prebypass or postbypass periods, indicating careful intraoperative control of hemodynamic indices did not prevent the outcome of PMI in these patients. However, the incidence of prebypass ischemia was 39.3% and significantly correlated with the outcome of positive TcPPi-SPECT, denoting a 3.9-fold increased risk of developing PMI. Prebypass ischemic changes in leads II and V5 were shown to correlate with increased CPK-MB release (P less than 0.05) and tends to occur more frequently with lateral myocardial infarction.« less

  10. [Course of ejection fraction, regurgitation fraction and ventricular volumes during exertion in chronic aortic insufficiency. Study using technetium 99m gamma-cineangiography].

    PubMed

    Bassand, J P; Faivre, R; Berthout, P; Cardot, J C; Verdenet, J; Bidet, R; Maurat, J P

    1985-06-01

    Previous studies have shown that variations of the ejection fraction (EF) during exercise were representative of the contractile state of the left ventricle: an increased EF on effort is considered to be physiological, whilst a decrease would indicate latent LV dysfunction unmasked during exercise. This hypothesis was tested by performing Technetium 99 gamma cineangiography at equilibrium under basal conditions and at maximal effort in 8 healthy subjects and 44 patients with pure, severe aortic regurgitation to measure the ejection and regurgitant fractions and the variations in end systolic and end diastolic LV volume. In the control group the EF increased and end systolic volume decreased significantly on effort whilst the regurgitant fraction and end diastolic volume were unchanged. In the 44 patients with aortic regurgitation no significant variations in EF, end systolic and end diastolic volumes were observed because the individual values were very dispersed. Variations of the EF and end systolic volume were inversely correlated. The regurgitant fraction decreased significantly on effort. Based on the variations of the EF and end systolic volume three different types of response to effort could be identified: in 7 patients, the EF increased on effort and end systolic volume decreased without any significant variation in the end diastolic volume, as in the group of normal control subjects; in 22 patients, a reduction in EF was observed on effort, associated with an increased end systolic volume. These changes indicated latent IV dysfunction inapparent at rest and unmasked by exercise; in a third group of 15 patients, the EF decreased on effort despite a physiological decrease in end systolic volume due to a greater decrease in end diastolic volume.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Human Fibronectin Extra-Domain B (EDB)-Specific Aptide (APTEDB) Radiolabelling with Technetium-99m as a Potent Targeted Tumour-Imaging Agent.

    PubMed

    Mohammadgholi, Mohsen; Sadeghzadeh, Nourollah; Erfani, Mostafa; Abediankenari, Saeid; Abedi, Seyed Mohammad; Emrarian, Iman; Jafari, Narjes; Behzadi, Ramezan

    2018-01-01

    Human fibronectin extra-domain B (EDB) is particularly expressed during angiogenesis progression. It is, thus, a promising marker of tumour growth. Aptides are a novel class of peptides with high-affinity binding to specific protein targets. APTEDB is an antagonist-like ligand that especially interacts with human fibronectin EDB. This study was the first attempt in which the hydrazinonicotinamide (HYNIC)-conjugated APTEDB was labelled with technetium-99m (99mTc) as an appropriate radiotracer and tricine/EDDA exchange labeling. Radiochemical purity, normal saline, and serum stability were evaluated by HPLC and radio-isotope TLC scanner. Other examinations, such as protein-binding calculation, dissociation radioligand binding assay, and partition coefficient constant determination, were also carried out. The cellular-specific binding of 99mTc- HYNIC-conjugated APTEDB was assessed in two EDB-positive (U87MG) and EDB-negative (U373MG) cell lines. Bio-distribution was investigated in normal mice as well as in U87MG and U373MG tumour-bearing mice. Eventually, the radiolabelled APTEDB was used for tumour imaging using planar SPECT. Radiolabelling was achieved with high purity (up to 97%) and accompanied by high solution (over 90% after overnight) and serum (80% after 2 hours) stability. The obtained cellular-specific binding ratio was greater than nine-fold. In-vivo experiments showed rapid blood clearance with mainly renal excretion and tumour uptake specificity (0.48±0.03% ID/g after 1h). The results of the imaging also confirmed considerable tumour uptake for EDB-positive cell line compared with the EDB-negative one. Aptides are considered to be a potent candidate for biopharmaceutical applications. They can be modified with imaging or therapeutic agents. This report shows the capability of 99mTc-HYNIC-APTEDB for human EDB-expressing tumours detection. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  12. Effect of metabolic alterations on the accumulation of technetium-99m-labeled d, l-HMPAO in slices of rat cerebral cortex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, C.S.; Tow, D.E.; Yu, C.C.

    1994-03-01

    It is widely recognized that the distribution of technetium-99m-labeled d,l-hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) in the brain is determined by the regional blood flow. However, other factors may affect this process including the metabolism of the brain tissue. To examine this possibility we studied the effects of metabolic alterations on {sup 99m}Tc-HMPAO uptake in rat brain cortex slices, with concurrent measurement of oxygen consumption (QO{sub 2}). {sup 99m}Tc-HMPAO uptake was determined by incubating slices of rat cerebral cortex at 37{degrees}C in Krebs-Ringer phosphate glucose medium containing {sup 99m}Tc-HMPAO with and without test substances. Differential gradients for {sup 99m}Tc activity betweenmore » the tissue and the suspending medium (T/M ratio) were derived from the equation T/M[{sup 99m}Tc] = counts per gram of tissue/counts per milliliter of medium. The QO{sub 2} of the brain slices was measured using a biological oxygen monitor equipped with a polarographic oxygen probe. Inhibitors affecting oxidative phosphorylation caused parallel suppression of the T/M ratio and QO{sub 2}. Agents that uncouple oxidation from phosphorylation increased the QO{sub 2} and decreased the T/M ratio. Incubation of slices at 22{degrees}C depressed the T/M ratio and QO{sub 2}. The presence of inhibitors of oxidative phosphorylation in the incubation medium increased the release of {sup 99m}Tc activity from slices that had been prelabeled with {sup 99m}Tc-HMPAO. These findings suggest that the altered metabolic status of the brain tissue modulates the kinetics and net accumulation of {sup 99m}Tc-HMPAO at the cellular level by either depressing uptake, increasing back-diffusion, or both. 33 refs., 4 figs., 3 tabs.« less

  13. 10 CFR 33.100 - Schedule A.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... .1 Technetium-99m 100 1. Technetium-99 1 .01 Tellurium-125m 1 .01 Tellurium-127m 1 .01 Tellurium-127 10 .1 Tellurium-129m 1 .01 Tellurium-129 100 1 Tellurium-131m 10 .1 Tellurium-132 1 .01 Terbium-160 1...

  14. 10 CFR 33.100 - Schedule A.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... .1 Technetium-99m 100 1. Technetium-99 1 .01 Tellurium-125m 1 .01 Tellurium-127m 1 .01 Tellurium-127 10 .1 Tellurium-129m 1 .01 Tellurium-129 100 1 Tellurium-131m 10 .1 Tellurium-132 1 .01 Terbium-160 1...

  15. Dissolution of spent nuclear fuel in carbonate-peroxide solution

    NASA Astrophysics Data System (ADS)

    Soderquist, Chuck; Hanson, Brady

    2010-01-01

    This study shows that spent UO2 fuel can be completely dissolved in a room temperature carbonate-peroxide solution apparently without attacking the metallic Mo-Tc-Ru-Rh-Pd fission product phase. In parallel tests, identical samples of spent nuclear fuel were dissolved in nitric acid and in an ammonium carbonate, hydrogen peroxide solution. The resulting solutions were analyzed for strontium-90, technetium-99, cesium-137, europium-154, plutonium, and americium-241. The results were identical for all analytes except technetium, where the carbonate-peroxide dissolution had only about 25% of the technetium that the nitric acid dissolution had.

  16. Radioguided localisation of impalpable breast lesions using 99m-Technetium macroaggregated albumin: Lessons learnt during introduction of a new technique to guide preoperative localisation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landman, Joanne; Kulawansa, Sagarika; McCarthy, Michael

    2015-03-15

    Preoperative wire-guided localisation (WGL) of impalpable breast lesions is widely used but can be technically difficult. Risks include wire migration, inaccurate placement, and inadequate surgical margins. Research shows that radioguided occult lesion localisation (ROLL) is quicker, easier, and can improve surgical and cosmetic outcomes. An audited introduction of ROLL was conducted to validate the technique as a feasible alternative to WGL. Fifty patients with single impalpable lesions and biopsy proven malignancy or indeterminate histology underwent WGL followed by intralesional radiopharmaceutical injection of 99m-Technetium macroaggregated albumin. Postprocedural mammography was performed to demonstrate wire position, and scintigraphy to evaluate radiopharmaceutical migration. Lymphoscintigraphymore » and intraoperative sentinel node biopsy were performed if indicated, followed by lesion localisation and excision using a gamma probe. Specimen imaging was performed, with immediate reexcision for visibly inadequate margins. Accurate localisation was achieved in 86% of patients with ROLL compared to 72% with WGL. All lesions were successfully removed, with clear margins in 71.8% of malignant lesions. Reexcision and intraoperative sentinel node localisation rates were equivalent to preaudit figures for WGL. ROLL was easy to perform and problems were infrequent. Inaccurate radiopharmaceutical placement necessitating WGL occurred in four patients. Minor radiopharmaceutical migration was common, but precluded using ROLL in only two cases. ROLL is effective, simple, inexpensive, and easily learnt; however, preoperative confirmation of correct radiopharmaceutical placement using mammography and the gamma probe is important to help ensure successful lesion removal. Insertion of a backup hookwire is recommended during the initial introduction of ROLL.« less

  17. Hanford Low-Activity Waste Processing: Demonstration of the Off-Gas Recycle Flowsheet - 13443

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramsey, William G.; Esparza, Brian P.

    2013-07-01

    Vitrification of Hanford Low-Activity Waste (LAW) is nominally the thermal conversion and incorporation of sodium salts and radionuclides into borosilicate glass. One key radionuclide present in LAW is technetium-99. Technetium-99 is a low energy, long-lived beta emitting radionuclide present in the waste feed in concentrations on the order of 1-10 ppm. The long half-life combined with a high solubility in groundwater results in technetium-99 having considerable impact on performance modeling (as potential release to the environment) of both the waste glass and associated secondary waste products. The current Hanford Tank Waste Treatment and Immobilization Plant (WTP) process flowsheet calls formore » the recycle of vitrification process off-gas condensates to maximize the portion of technetium ultimately immobilized in the waste glass. This is required as technetium acts as a semi-volatile specie, i.e. considerable loss of the radionuclide to the process off-gas stream can occur during the vitrification process. To test the process flowsheet assumptions, a prototypic off-gas system with recycle capability was added to a laboratory melter (on the order of 1/200 scale) and testing performed. Key test goals included determination of the process mass balance for technetium, a non-radioactive surrogate (rhenium), and other soluble species (sulfate, halides, etc.) which are concentrated by recycling off-gas condensates. The studies performed are the initial demonstrations of process recycle for this type of liquid-fed melter system. This paper describes the process recycle system, the waste feeds processed, and experimental results. Comparisons between data gathered using process recycle and previous single pass melter testing as well as mathematical modeling simulations are also provided. (authors)« less

  18. Characterization of Vadose Zone Sediment: Borehole 299-E33-46 Near Tank B-110 in the B-BX-BY Waste Management Area.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Serne, R. Jeffrey; Bjornstad, Bruce N.; Gee, Glendon W.

    2002-12-15

    This report presents vadose sediment characterization data that improves understanding of the nature and extent of past releases in the B tank farm. A vertical borehole, located approximately 15 ft (5 m) from the northeast edge of single-shell tank 241-B-110 was drilled to a total depth of 264.4 ft bgs, the groundwater table was encountered at 255.8 ft bgs. During drilling, a total of 3 two-ft long, 4-inch diameter split-spoon core samples were collected between 10 and 254 ft bgs-an average of every 7.5 ft. Grab samples were collected between these core sample intervals to yield near continuous samples tomore » a depth of 78.3 m (257 ft). Geologic logging occurred after each core segment was emptied into an open plastic container, followed by photographing and sub-sampling for physical and chemical characterization. In addition, 54 out of a total of 120 composite grab samples were opened, sub-sampled, logged, and photographed. Immediately following the geologic examination, the core and selected grab samples were sub-sampled for moisture content, gamma-emission radiocounting, tritium and strontium-90 determinations, total carbon and inorganic carbon content, and 8 M nitric acid extracts (which provide a measure of the total leachable sediment content of contaminants) and one-to-one sediment to water extracts (which provide soil pH, electrical conductivity, cation, and anion data and water soluble contaminant data. Later, additional aliquots of selected sleeves or grab samples were removed to measure particle size distribution and mineralogy and to squeeze porewater. Major conclusions follow. Vadose zone contamination levels were lower than generally anticipated prior to the initiation of the field investigation. Strong evidence of extensive vadose zone lateral migration in WMA BBXBY exists. There are indications that such lateral migration may have extended into WMA B-BX-BY from adjacent past practice discharge sites. Ponding of runoff from natural precipitation

  19. Technetium-99m-Labeled Sulfadiazine: a Targeting Radiopharmaceutical for Scintigraphic Imaging of Infectious Foci Due To Escherichia coli in Mouse and Rabbit Models.

    PubMed

    Ahmed, Muhammad Tauqeer; Naqvi, Syed Ali Raza; Rasheed, Rashid; Zahoor, Ameer Fawad; Usman, Muhammad; Hussain, Zaib

    2017-09-01

    Bacterial infection is one of the vital reasons of morbidity and mortality, especially in developing countries. It appears silently without bothering the geological borders and imposes a grave threat to humanity. Nuclear medicine technique has an important role in helping early diagnosis of deep-seated infections. The aim of this study was to develop a new radiopharmaceutical 99m Tc-labeling sulfadiazine as an infection imaging agent. Radiolabeling of sulfadiazine with technetium-99m ( 99m Tc) was carried out using stannous tartrate as a reducing agent in the presence of gentistic acid at pH = 5. The quality control tests revealed ~98% labeling efficiency. Paper chromatographic (PC) and instant thin-layer chromatographic (ITLC) techniques were used to analyze radiochemical yield. Biodistribution and infection specificity of the radiotracer were performed with Escherichia coli (E. coli) infection-induced rats. Scintigraphy and glomerular filtration rate (GFR) study was performed in E. coli-infected rabbits. Scintigraphy indicated E. coli infection targeting potential of 99m Tc-SDZ, while biodistribution study showed minimal uptake of 99m Tc-SDZ in non-targeted tissues. The uptake in the kidneys was found 2.56 ± 0.06, 2.09 ± 0.10, and 1.68 ± 0.09% at 30 min, 1 h, and 4 h, respectively. The infected muscle (target) to non-infected muscle (non-target) ratio (T/NT) was found 4.49 ± 0.04, 6.78 ± 0.07, and 5.59 ± 0.08 at 30 min, 1 h, and 4 h, respectively.

  20. Breaking America’s Dependence on Foreign…Molybdenum

    PubMed Central

    Einstein, Andrew J.

    2009-01-01

    Brief Unstructured Abstract Approximately 9 million nuclear cardiology studies performed each year in the United States employ technetium-99m, which is produced from the decay of molybdenum-99. The fragility of the worldwide technetium-99m supply chain has been underscored by current shortages caused by an unplanned shutdown of Europe’s largest reactor. The majority of the United States’ supply derives from a reactor in Canada nearing the end of its lifespan, whose planned replacements have been recently cancelled. In this article, the clinical importance of technetium-99m and our tenuous dependence on foreign supply of Molybdenum is addressed. PMID:19356583

  1. Differences in the intracellular processing of the radiolabel following the uptake of iodine-125- and technetium-99m-neogalactosyl albumin by the isolated perfused rat liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gore, S.; Morris, A.I.; Gilmore, I.T.

    1991-03-01

    Neogalactosyl albumin (NGA) is a synthetic ligand to the asialoglycoprotein receptor (hepatic binding protein), which has been proposed as a useful receptor binding radiopharmaceutical for the noninvasive assessment of liver function. We have compared the uptake and intracellular processing of iodine-125- (125I) and technetium-99m- ({sup 99m}Tc) NGA following its administration as a 1-min pulse (147 pmol) to the isolated perfused rat liver. Approximately 40% of a pulse of either {sup 125}I- or {sup 99m}Tc-NGA were taken up first pass by the liver. Of the {sup 125}I taken up by the liver, 82% was released after 15-20 min at the sinusoidalmore » pole of the hepatocyte, predominantly as small molecular weight metabolites. A further 8% of the {sup 125}I-associated radioactivity was secreted as intact NGA into bile by the non-lysosomal (direct) pathway while 6% remained in the liver 1 hr after the pulse. In contrast, of the {sup 99m}Tc taken up by the liver, only 4% reappeared in the perfusate while 40% was secreted into bile by the lysosomal (indirect) pathway and 55% remained in the liver 1 hr after the pulse. Since labeled metabolites of {sup 99m}Tc-NGA do not appear in plasma, this permits kinetic modeling with {sup 99m}Tc-NGA without correction for labeled metabolites. Thus, {sup 99m}Tc-NGA is an excellent candidate as a receptor-binding radiopharmaceutical.« less

  2. Technetium tc 99m-labeled red blood cells in the preoperative diagnosis of cavernous hemangioma and other vascular orbital tumors.

    PubMed

    Polito, Ennio; Burroni, Luca; Pichierri, Patrizia; Loffredo, Antonio; Vattimo, Angelo G

    2005-12-01

    To evaluate technetium Tc 99m (99mTc) red blood cell scintigraphy as a diagnostic tool for orbital cavernous hemangioma and to differentiate between orbital masses on the basis of their vascularization. We performed 99mTc red blood cell scintigraphy on 23 patients (8 female and 15 male; mean age, 47 years) affected by an orbital mass previously revealed with computed tomography (CT) and magnetic resonance imaging (MRI) and suggesting cavernous hemangioma. In our diagnosis, we considered the orbital increase delayed uptake with the typical scintigraphic pattern known as perfusion blood pool mismatch. The patients underwent biopsy or surgical treatment with transconjunctival cryosurgical extraction when possible. Single-photon emission tomography (SPET) showed intense focal uptake in the orbit corresponding to radiologic findings in 11 patients who underwent surgical treatment and pathologic evaluation (9 cavernous hemangiomas, 1 hemangiopericytoma, and 1 lymphangioma). Clinical or histologic examination of the remaining 22 patients revealed the presence of 5 lymphoid pseudotumors, 2 lymphomas, 2 pleomorphic adenomas of the lacrimal gland, 1 astrocytoma, 1 ophthalmic vein thrombosis, and 1 orbital varix. The confirmation of the preoperative diagnosis by 99mTc red blood cell scintigraphy shows that this technique is a reliable tool for differentiating cavernous hemangiomas from other orbital masses (sensitivity, 100%; specificity, 86%) when ultrasound, CT, and MRI are not diagnostic. Unfortunately, 99mTc red blood cell scintigraphy results were positive in 1 patient with hemangiopericytoma and 1 patient with lymphangioma, which showed increased uptake in the lesion on SPET images because of the vascular nature of these tumors. Therefore, in these cases, the SPET images have to be integrated with data regarding clinical preoperative evaluation and CT scans or MRI studies. On the basis of our study, a complete diagnostic picture, CT scans or MRI studies, and

  3. Use of carbonated water in reduction of adjacent gastric activity in 456 consecutive technetium-99m myocardial perfusion imaging studies.

    PubMed

    Thomas, Dustin M; Lee, Joshua S; Charmforoush, Anthony; Rubal, Bernard J; Rosenblatt, Stephen A; Butler, Joshua T; Clemenshaw, Michael; Cheezum, Michael K; Slim, Ahmad M

    2015-12-01

    Small, observational trials have suggested a reduction in adjacent gastric activity with ingestion of soda water in myocardial perfusion imaging (MPI). We report our findings prior to and after implementation of soda water in 467 consecutive MPI studies. Consecutive MPI studies performed at a high-volume facility referred for vasodilator (VD) or exercise treadmill testing (ETT) were retrospectively reviewed before and after implementation of the soda water protocol. Patients undergoing the soda water protocol received 100 ml of soda water administered 30 min prior to image acquisition and after stress. Studies were performed using a same day rest/stress protocol. Incidence of adjacent gastric activity, diaphragmatic attenuation, stress and rest perfusion defects, and major adverse cardiovascular events (MACE) outcomes defined as death, myocardial infarction, stroke, reevaluation for chest pain, and late revascularization (>90 days from MPI) were abstracted using International Classification of Diseases, Ninth Revision (ICD-9) search. Two hundred and eighteen studies were performed prior to implementation of the soda water protocol and 249 studies were performed with the use of soda water. Baseline demographic data were equal between the groups with the exception of more patients undergoing VD stress receiving soda water (p < 0.001). Soda water was not associated with a decreased incidence of adjacent gastric activity with stress (54.7% versus 61.9% with no soda water, p = 0.129) or rest (68.6% versus 69.5% with no soda water, p = 0.919) imaging. Less adjacent gastric activity was observed with patients undergoing ETT who received soda water (42.5% versus 56.9% with no soda water, p = 0.031), but no difference was observed between the groups with VD stress (69.0% versus 68.1% with no soda water, p = 1.000). The use of soda water prior to technetium-99m MPI was associated with lower rates of adjacent gastric activity only in patients undergoing ETT stress but not

  4. Nuclear cardiology: Part 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Berger, H.J.; Zaret, B.L.

    1981-10-01

    A review of recent developments and future directions in nuclear cardiology is presented. Myocardial perfusion imaging is discussed with special emphasis on thallium-201 methods. Infarct-avid imaging is also discussed with emphasis on technetium-99m labelled in diagnosis, and emission computed tomography is briefly reviewed. In addition, new biologically based radiotracers such as indium-111-labeled blood cells, gallium-67 citrate, and new positron- and gamma-emittng radiotracers are reviewed.

  5. Scintigraphic evaluation in musculoskeletal sepsis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merkel, K.D.; Fitzgerald, R.H. Jr.; Brown, M.L.

    In this article, the mechanism of technetium, gallium, and indium-labeled white blood cell localization in septic processes is detailed, and the method of interpretation of these three isotopes with relationship to musculoskeletal infection is outlined. Specific clinical application of technetium, gallium, and indium-labeled white blood cell imaging for musculoskeletal sepsis is reviewed.

  6. Breaking America's dependence on imported molybdenum.

    PubMed

    Einstein, Andrew J

    2009-03-01

    Approximately 9 million nuclear cardiology studies performed each year in the U.S. use technetium-99m, which is produced from the decay of molybdenum-99. The fragility of the worldwide technetium-99m supply chain has been underscored by current shortages caused by an unplanned shutdown of Europe's largest reactor. The majority of the U.S. supply derives from a reactor in Canada that is nearing the end of its lifespan and whose planned replacements have been cancelled recently. In this article, the clinical importance of technetium-99m and our tenuous dependence on the foreign supply of molybdenum are addressed, along with potential measures that may be taken to ensure that America's supply chain remains unbroken.

  7. Inter- and intraobserver variability of (semi-)quantitative parameters commonly used in feline thyroid scintigraphy.

    PubMed

    Volckaert, Veerle; Vandermeulen, Eva; Duchateau, Luc; Saunders, Jimmy H; Peremans, Kathelijne

    2016-04-01

    The aim of this study was to assess inter- and intraobserver variability of commonly used semi-quantitative and quantitative parameters in feline thyroid scintigraphy: thyroid to salivary gland ratio (T/S), thyroid to background ratio (T/B) and the percentage technetium pertechnetate uptake for the thyroid glands (%TcUT). These parameters are being used to diagnose thyroid disease and to assess its severity, but may be influenced by operator related factors when processing the images. Additionally, inter- and intraobserver variability of the percentage technetium pertechnetate uptake for the salivary glands was determined (%TcUSG). The study included technetium pertechnetate scans of 100 hyperthyroid cats. Variability within and between three observers was determined using a random effects model and variance components were estimated by the restricted maximum likelihood procedure. The %TcU for the thyroid and salivary glands, as well as the T/S ratio, showed little to no difference in inter- and intraobserver variability, whereas this was clearly present for the T/B ratio. Overall, the T/S ratio and %TcUSG showed a good repeatability and reproducibility with low inter- and intraobserver variabilities. Inter- and intraobserver variability was higher for the %TcUT, however variations were still considered to be acceptable. On the contrary, inter- and intraobserver variability was clearly larger for the T/B ratio. These findings suggest the preferential use of the T/S ratio or %TcU, especially in facilities with a less experienced staff. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.

  8. Getters for improved technetium containment in cementitious waste forms

    DOE PAGES

    Asmussen, R. Matthew; Pearce, Carolyn I.; Miller, Brian W.; ...

    2017-07-26

    A cementitious waste form, Cast Stone, is a possible candidate technology for the immobilization of low activity nuclear waste (LAW) at the Hanford site. This paper focuses on the addition of getter materials to Cast Stone that can sequester Tc from the LAW, and in turn, lower Tc release from the Cast Stone. Two getters which produce different products upon sequestering Tc from LAW were tested: Sn(II) apatite (Sn-A) that removes Tc as a Tc(IV)-oxide and potassium metal sulfide (KMS-2) that removes Tc as a Tc(IV)-sulfide species, allowing for a comparison of stability of the form of Tc upon enteringmore » the waste form. The Cast Stone with KMS-2 getter had the best performance with addition equivalent to ~0.08 wt% of the total waste form mass. The observed diffusion (D obs) of Tc decreased from 4.6 ± 0.2 × 10 -12 cm 2/s for Cast Stone that did not contain a getter to 5.4 ± 0.4 × 10 -13 cm 2/s for KMS-2 containing Cast Stone. Finally, it was found that Tc-sulfide species are more stable against re-oxidation within getter containing Cast Stone compared with Tc-oxide and is the origin of the decrease in Tc D obs when using the KMS-2.« less

  9. Getters for improved technetium containment in cementitious waste forms.

    PubMed

    Asmussen, R Matthew; Pearce, Carolyn I; Miller, Brian W; Lawter, Amanda R; Neeway, James J; Lukens, Wayne W; Bowden, Mark E; Miller, Micah A; Buck, Edgar C; Serne, R Jeffery; Qafoku, Nikolla P

    2018-01-05

    A cementitious waste form, Cast Stone, is a possible candidate technology for the immobilization of low activity nuclear waste (LAW) at the Hanford site. This work focuses on the addition of getter materials to Cast Stone that can sequester Tc from the LAW, and in turn, lower Tc release from the Cast Stone. Two getters which produce different products upon sequestering Tc from LAW were tested: Sn(II) apatite (Sn-A) that removes Tc as a Tc(IV)-oxide and potassium metal sulfide (KMS-2) that removes Tc as a Tc(IV)-sulfide species, allowing for a comparison of stability of the form of Tc upon entering the waste form. The Cast Stone with KMS-2 getter had the best performance with addition equivalent to ∼0.08wt% of the total waste form mass. The observed diffusion (D obs ) of Tc decreased from 4.6±0.2×10 -12 cm 2 /s for Cast Stone that did not contain a getter to 5.4±0.4×10 -13 cm 2 /s for KMS-2 containing Cast Stone. It was found that Tc-sulfide species are more stable against re-oxidation within getter containing Cast Stone compared with Tc-oxide and is the origin of the decrease in Tc D obs when using the KMS-2. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. Initial results of metal waste-form development activities at ANL-West

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Keiser, D.D. Jr.; Westphal, B.R.; Herbst, R.S.

    1997-12-01

    Argonne National Laboratory (ANL) is developing a metal alloy to contain metallic waste constituent residual from the electrometallurgical treatment of spent nuclear fuel. This alloy will contain stainless steel (from stainless steel-clad fuel elements), {approximately} 15 wt% zirconium (from alloy fuel), fission products noble to the process (e.g., ruthenium, palladium, technetium, etc.), and minor amounts of actinides. The alloy will serve as a final waste form for these components and will be disposed of in a geologic repository. The alloy ingot is produced in an induction furnace situated in a hot cell using argon cover gas. This paper discusses resultsmore » from the melting campaigns that have been initiated at ANL-West to generate the metal waste form using actual process materials. In addition, metal waste form samples have been doped with technetium and selected actinides and are described in the context of how elements of interest partition between various phases in the alloy and how this distribution of elements in the alloy may affect the leaching behavior of the components in an aqueous environment.« less

  11. Nuclear cardiology: Myocardial perfusion and function

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seldin, D.W.

    1991-08-01

    Myocardial perfusion studies continue to be a major focus of research, with new investigations of the relationship of exercise-redistribution thallium imaging to diagnosis, prognosis, and case management. The redistribution phenomenon, which seemed to be fairly well understood a few years ago, is now recognized to be much more complex than originally thought, and various strategies have been proposed to clarify the meaning of persistent defects. Pharmacologic intervention with dipyridamole and adenosine has become available as an alternative to exercise, and comparisons with exercise imaging and catheterization results have been described. Thallium itself is no longer the sole single-photon perfusion radiopharmaceutical;more » two new technetium agents are now widely available. In addition to perfusion studies, advances in the study of ventricular function have been made, including reports of studies performed in conjunction with technetium perfusion studies, new insights into cardiac physiology, and the prognostic and case-management information that function studies provide. Finally, work has continued with monoclonal antibodies for the identification of areas of myocyte necrosis. 41 references.« less

  12. TECHNETIUM RETENTION IN WTP LAW GLASS WITH RECYCLE FLOW-SHEET DM10 MELTER TESTING VSL-12R2640-1 REV 0

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abramowitz, Howard; Brandys, Marek; Cecil, Richard

    2012-12-11

    Melter tests were conducted to determine the retention of technetium and other volatiles in glass while processing simulated Low Activity Waste (LAW) streams through a DM10 melter equipped with a prototypical off-gas system that concentrates and recycles fluid effiuents back to the melter feed. To support these tests, an existing DM10 system installed at Vitreous State Laboratory (VSL) was modified to add the required recycle loop. Based on the Hanford Tank Waste Treatment and Immobilization Plant (WTP) LAW off-gas system design, suitably scaled versions of the Submerged Bed Scrubber (SBS), Wet Electrostatic Precipitator (WESP), and TLP vacuum evaporator were designed,more » built, and installed into the DM10 system. Process modeling was used to support this design effort and to ensure that issues associated with the short half life of the {sup 99m}Tc radioisotope that was used in this work were properly addressed and that the system would be capable of meeting the test objectives. In particular, this required that the overall time constant for the system was sufficiently short that a reasonable approach to steady state could be achieved before the {sup 99m}Tc activity dropped below the analytical limits of detection. The conceptual design, detailed design, flow sheet development, process model development, Piping and Instrumentation Diagram (P&ID) development, control system design, software design and development, system fabrication, installation, procedure development, operator training, and Test Plan development for the new system were all conducted during this project. The new system was commissioned and subjected to a series of shake-down tests before embarking on the planned test program. Various system performance issues that arose during testing were addressed through a series of modifications in order to improve the performance and reliability of the system. The resulting system provided a robust and reliable platform to address the test objectives.« less

  13. Food additives.

    PubMed

    Berglund, F

    1978-01-01

    The use of additives to food fulfils many purposes, as shown by the index issued by the Codex Committee on Food Additives: Acids, bases and salts; Preservatives, Antioxidants and antioxidant synergists; Anticaking agents; Colours; Emulfifiers; Thickening agents; Flour-treatment agents; Extraction solvents; Carrier solvents; Flavours (synthetic); Flavour enhancers; Non-nutritive sweeteners; Processing aids; Enzyme preparations. Many additives occur naturally in foods, but this does not exclude toxicity at higher levels. Some food additives are nutrients, or even essential nutritents, e.g. NaCl. Examples are known of food additives causing toxicity in man even when used according to regulations, e.g. cobalt in beer. In other instances, poisoning has been due to carry-over, e.g. by nitrate in cheese whey - when used for artificial feed for infants. Poisonings also occur as the result of the permitted substance being added at too high levels, by accident or carelessness, e.g. nitrite in fish. Finally, there are examples of hypersensitivity to food additives, e.g. to tartrazine and other food colours. The toxicological evaluation, based on animal feeding studies, may be complicated by impurities, e.g. orthotoluene-sulfonamide in saccharin; by transformation or disappearance of the additive in food processing in storage, e.g. bisulfite in raisins; by reaction products with food constituents, e.g. formation of ethylurethane from diethyl pyrocarbonate; by metabolic transformation products, e.g. formation in the gut of cyclohexylamine from cyclamate. Metabolic end products may differ in experimental animals and in man: guanylic acid and inosinic acid are metabolized to allantoin in the rat but to uric acid in man. The magnitude of the safety margin in man of the Acceptable Daily Intake (ADI) is not identical to the "safety factor" used when calculating the ADI. The symptoms of Chinese Restaurant Syndrome, although not hazardous, furthermore illustrate that the whole ADI

  14. Additive manufacturing.

    PubMed

    Mumith, A; Thomas, M; Shah, Z; Coathup, M; Blunn, G

    2018-04-01

    Increasing innovation in rapid prototyping (RP) and additive manufacturing (AM), also known as 3D printing, is bringing about major changes in translational surgical research. This review describes the current position in the use of additive manufacturing in orthopaedic surgery. Cite this article: Bone Joint J 2018;100-B:455-60.

  15. Comparison of early myocardial technetium-99m pyrophosphate uptake to early peaking of creatine kinase and creatine kinase-MB as indicators of early reperfusion in acute myocardial infarction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondo, M.; Yuzuki, Y.; Arai, H.

    1987-10-01

    The value of technetium-99m pyrophosphate (Tc-99m-PYP) scintigraphy as an indicator of reperfusion 2.8 to 8 hours after the onset of symptoms of acute myocardial infarction was compared with the value of early peak creatine kinase (CK) and CK-MB release within 16 hours after the onset of symptoms. In 29 patients who received thrombolytic therapy, recanalization was seen (group 1) and in 7 it was not (group 2). In 23 patients (79%) in group 1 scintigraphic findings were positive and in all 7 in group 2 they were negative. In 15 patients (52%) in group 1 and 1 patient (14%) inmore » group 2, CK reached its peak level within 16 hours. In 20 patients (69%) in group 1 and 3 (43%) in group 2 the CK-MB level reached a peak within 16 hours. The sensitivity, specificity and predictive accuracy of positive results of early Tc-99m-PYP scintigraphy in predicting the reperfusion were 79%, 100% and 83%. These values are significantly higher than or similar to those of early peaking of CK and CK-MB release. In contrast to measurements of enzyme release, reperfusion data for Tc-99m-PYP scintigraphy are available immediately after thrombolytic therapy. Therefore, early Tc-99m-PYP scintigraphy (3 to 8 hours after onset of symptoms) is valuable as a noninvasive technique for early diagnosis of reperfusion.« less

  16. The Geochemistry of Technetium: A Summary of the Behavior of an Artificial Element in the Natural Environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Icenhower, Jonathan P.; Qafoku, Nikolla; Martin, Wayne J.

    Interest in the chemistry of technetium has only increased since its discovery in 1937, mainly because of the large and growing inventory of 99Tc generated during fission of 235U, its environmental mobility in oxidizing conditions, and its potential radiotoxicity. For every ton of enriched uranium fuel (3% 235U) that is consumed at a typical burn-up rate, nearly 1 kg of 99Tc is generated. Thus, the mass of 99Tc produced since 1993 has nearly quadrupled, and will likely to continue to increase if more emphasis is placed on nuclear power to slow the accumulation of atmospheric greenhouse gases. In order tomore » gain a comprehensive understanding of the interaction of 99Tc and the natural environment, we review the sources of 99Tc in the nuclear fuel cycle, its chemical properties, radiochemistry, and biogeochemical behavior. We include an evaluation of the use of Re as a chemical analog of Tc, as well as a summary of the redox potential, thermodynamics, sorption, colloidal behavior, and interaction of humic substances with Tc, and the potential for re-oxidation and remobilization of Tc(IV). What emerges is a more complicated picture of Tc behavior than that of an easily tractable transition of Tc(VII) to Tc(IV) with consequent immobilization. Reducing conditions (+200 to +100 mV Eh) are generally thought necessary to cause reduction of Tc(VII) to Tc(IV), but far more important are the presence of reducing agents, such as Fe(II) sorbed onto mineral grains. Catalysis of Tc(VII) by surface-mediated Fe(II) will bring the mobile Tc(VII) species to a lower oxidation state and will form the relatively insoluble Tc(IV)O2∙nH2O, but even as a solid, equilibrium concentrations of aqueous Tc are nearly a factor of 20× above the EPA set drinking water standards. However, sequestration of Tc(IV) into Fe(III)-bearing phases, such as goethite or other hydrous oxyhydroxides of iron, may ameliorate concerns over the mobility of Tc. Further, the outcome of many studies on

  17. Value of imaging studies after a first febrile urinary tract infection in young children: data from Italian renal infection study 1.

    PubMed

    Montini, Giovanni; Zucchetta, Pietro; Tomasi, Lisanna; Talenti, Enrico; Rigamonti, Waifro; Picco, Giorgio; Ballan, Alberto; Zucchini, Andrea; Serra, Laura; Canella, Vanna; Gheno, Marta; Venturoli, Andrea; Ranieri, Marco; Caddia, Valeria; Carasi, Carla; Dall'amico, Roberto; Hewitt, Ian

    2009-02-01

    We examined the diagnostic accuracy of routine imaging studies (ultrasonography and micturating cystography) for predicting long-term parenchymal renal damage after a first febrile urinary tract infection. This study addressed the secondary objective of a prospective trial evaluating different antibiotic regimens for the treatment of acute pyelonephritis. Data for 300 children < or =2 years of age, with normal prenatal ultrasound results, who completed the diagnostic follow-up evaluation (ultrasonography and technetium-99m-dimercaptosuccinic acid scanning within 10 days, cystography within 2 months, and repeat technetium-99m-dimercaptosuccinic acid scanning at 12 months to detect scarring) were analyzed. Outcome measures were sensitivity, specificity, and negative and positive predictive values for ultrasonography and cystography in predicting parenchymal renal damage on the 12-month technetium-99m-dimercaptosuccinic acid scans. The kidneys and urinary tracts were mostly normal. The acute technetium-99m-dimercaptosuccinic acid scans showed pyelonephritis in 54% of cases. Renal scarring developed in 15% of cases. The ultrasonographic and cystographic findings were poor predictors of long-term damage, showing minor sonographic abnormalities for 12 and reflux for 23 of the 45 children who subsequently developed scarring. The benefit of performing ultrasonography and scintigraphy in the acute phase or cystourethrography is minimal. Our findings support (1) technetium-99m-dimercaptosuccinic acid scintigraphy 6 months after infection to detect scarring that may be related to long-term hypertension, proteinuria, and renal function impairment (although the degree of scarring was generally minor and did not impair renal function) and (2) continued surveillance to identify recurrent urinary tract infections that may warrant further investigation.

  18. Process for the recovery of strontium from acid solutions

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1992-01-01

    The invention is a process for selectively extracting strontium and technetium values from aqueous nitric acid waste solutions containing these and other fission product values. The extractant is a macrocyclic polyether in a diluent which is insoluble in water, but which will itself dissolve a small amount of water. The process will extract strontium and technetium values from nitric acid solutions which are up to 6 molar in nitric acid.

  19. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial.

    PubMed

    Montz, R; Perez-Castejón, M J; Jurado, J A; Martín-Comín, J; Esplugues, E; Salgado, L; Ventosa, A; Cantinho, G; Sá, E P; Fonseca, A T; Vieira, M R

    1996-06-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with /=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99mTc tetrofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h).

  20. 21 CFR 25.32 - Foods, food additives, and color additives.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... use in food, drugs, devices, or cosmetics. (d) Testing and certification of batches of a color... 21 Food and Drugs 1 2011-04-01 2011-04-01 false Foods, food additives, and color additives. 25.32 Section 25.32 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL...

  1. 21 CFR 25.32 - Foods, food additives, and color additives.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... use in food, drugs, devices, or cosmetics. (d) Testing and certification of batches of a color... 21 Food and Drugs 1 2012-04-01 2012-04-01 false Foods, food additives, and color additives. 25.32 Section 25.32 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL...

  2. 21 CFR 25.32 - Foods, food additives, and color additives.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... use in food, drugs, devices, or cosmetics. (d) Testing and certification of batches of a color... 21 Food and Drugs 1 2013-04-01 2013-04-01 false Foods, food additives, and color additives. 25.32 Section 25.32 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL...

  3. 21 CFR 25.32 - Foods, food additives, and color additives.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... use in food, drugs, devices, or cosmetics. (d) Testing and certification of batches of a color... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Foods, food additives, and color additives. 25.32 Section 25.32 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL...

  4. 21 CFR 25.32 - Foods, food additives, and color additives.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... use in food, drugs, devices, or cosmetics. (d) Testing and certification of batches of a color... 21 Food and Drugs 1 2014-04-01 2014-04-01 false Foods, food additives, and color additives. 25.32 Section 25.32 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL...

  5. [Food additives and healthiness].

    PubMed

    Heinonen, Marina

    2014-01-01

    Additives are used for improving food structure or preventing its spoilage, for example. Many substances used as additives are also naturally present in food. The safety of additives is evaluated according to commonly agreed principles. If high concentrations of an additive cause adverse health effects for humans, a limit of acceptable daily intake (ADI) is set for it. An additive is a risk only when ADI is exceeded. The healthiness of food is measured on the basis of nutrient density and scientifically proven effects.

  6. Polyimide processing additives

    NASA Technical Reports Server (NTRS)

    Fletcher, James C. (Inventor); Pratt, J. Richard (Inventor); St.clair, Terry L. (Inventor); Stoakley, Diane M. (Inventor); Burks, Harold D. (Inventor)

    1992-01-01

    A process for preparing polyimides having enhanced melt flow properties is described. The process consists of heating a mixture of a high molecular weight poly-(amic acid) or polyimide with a low molecular weight amic acid or imide additive in the range of 0.05 to 15 percent by weight of additive. The polyimide powders so obtained show improved processability, as evidenced by lower melt viscosity by capillary rheometry. Likewise, films prepared from mixtures of polymers with additives show improved processability with earlier onset of stretching by TMA.

  7. Polyimide processing additives

    NASA Technical Reports Server (NTRS)

    Pratt, J. Richard (Inventor); St.clair, Terry L. (Inventor); Stoakley, Diane M. (Inventor); Burks, Harold D. (Inventor)

    1993-01-01

    A process for preparing polyimides having enhanced melt flow properties is described. The process consists of heating a mixture of a high molecular weight poly-(amic acid) or polyimide with a low molecular weight amic acid or imide additive in the range of 0.05 to 15 percent by weight of the additive. The polyimide powders so obtained show improved processability, as evidenced by lower melt viscosity by capillary rheometry. Likewise, films prepared from mixtures of polymers with additives show improved processability with earlier onset of stretching by TMA.

  8. Copper crystal lens for medical imaging: first results

    NASA Astrophysics Data System (ADS)

    Roa, Dante E.; Smither, Robert K.

    2001-06-01

    A copper crystal lens designed to focus gamma ray energies of 100 to 200 keV has been assembled at Argonne National Laboratory. In particular, the lens has been optimized to focus the 140.6 keV gamma rays from technetium-99 m typically used in radioactive tracers. This new approach to medical imaging relies on crystal diffraction to focus incoming gamma rays in a manner similar to a simple convex lens focusing visible light. The lens is envisioned to be part of an array of lenses that can be used as a complementary technique to gamma cameras for localized scans of suspected tumor regions in the body. In addition, a 2- lens array can be used to scan a woman's breast in search of tumors with no discomfort to the patient. The incoming gamma rays are diffracted by a set of 828 copper crystal cubes arranged in 13 concentric rings, which focus the gamma rays into a very small area on a well-shielded NaI detector. Experiments performance with technetium-99 m and cobalt 57 radioactive sources indicate that a 6-lens array should be capable of detecting sources with (mu) Ci strength.

  9. Reduction of pertechnetate by acetohydroxamic acid: Formation of [TcNO(AHA)2(H2O)]+ and implications for the UREX process.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    1Harry Reid Center for Environmental Studies, Nuclear Science and Technology Division, University of Nevada, Las Vegas, Las Vegas, NV, 89154-4006; Gong, Cynthia-May S; Poineau, Frederic

    2008-02-26

    Reductive nitrosylation and complexation of ammonium pertechnetate by acetohydroxamic acid has been achieved in aqueous nitric and perchloric acid solutions. The kinetics of the reaction depend on the relative concentrations of the reaction components and are accelerated at higher temperatures. The reaction does not occur unless conditions are acidic. Analysis of the x-ray absorption fine structure spectroscopic data is consistent with a pseudo-octahedral geometry with the linear Tc-N-O bond typical of technetium nitrosyl compounds, and electron spin resonance spectroscopy is consistent with a the d{sup 5} Tc(II) nitrosyl complex. The nitrosyl source is generally AHA, but may be augmented bymore » products of reaction with nitric acid. The resulting low-valency trans-aquonitrosyl(diacetohydroxamic)-technetium(II) complex (1) is highly soluble in water, extremely hydrophilic, and is not extracted by tri-n-butylphosphate in a dodecane diluent. Its extraction properties are not pH-dependent; titration studies indicate a single species from pH 4.5 down to -0.6 (calculated). This molecule is resistant to oxidation by H{sub 2}O{sub 2}, even at high pH, and can undergo substitution to form other technetium nitrosyl complexes. The formation of 1 may strongly impact the fate of technetium in the nuclear fuel cycle.« less

  10. Magnetic core mesoporous silica nanoparticles doped with dacarbazine and labelled with 99mTc for early and differential detection of metastatic melanoma by single photon emission computed tomography.

    PubMed

    Portilho, Filipe Leal; Helal-Neto, Edward; Cabezas, Santiago Sánchez; Pinto, Suyene Rocha; Dos Santos, Sofia Nascimento; Pozzo, Lorena; Sancenón, Félix; Martínez-Máñez, Ramón; Santos-Oliveira, Ralph

    2018-02-27

    Cancer is responsible for more than 12% of all causes of death in the world, with an annual death rate of more than 7 million people. In this scenario melanoma is one of the most aggressive ones with serious limitation in early detection and therapy. In this direction we developed, characterized and tested in vivo a new drug delivery system based on magnetic core-mesoporous silica nanoparticle that has been doped with dacarbazine and labelled with technetium 99 m to be used as nano-imaging agent (nanoradiopharmaceutical) for early and differential diagnosis and melanoma by single photon emission computed tomography. The results demonstrated the ability of the magnetic core-mesoporous silica to be efficiently (>98%) doped with dacarbazine and also efficiently labelled with 99mTc (technetium 99 m) (>99%). The in vivo test, using inducted mice with melanoma, demonstrated the EPR effect of the magnetic core-mesoporous silica nanoparticles doped with dacarbazine and labelled with technetium 99 metastable when injected intratumorally and the possibility to be used as systemic injection too. In both cases, magnetic core-mesoporous silica nanoparticles doped with dacarbazine and labelled with technetium 99 metastable showed to be a reliable and efficient nano-imaging agent for melanoma.

  11. Geochemical behavior of Cs, Sr, Tc, Np, and U in saline groundwaters: Sorption experiments on shales and their clay mineral components: Progress report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meyer, R.E.; Arnold, W.D.; Ho, P.C.

    1987-11-01

    The Sedimentary Rock Program at the Oak Ridge National Laboratory is investigating shale to determine its potential suitability as a host rock for the disposal of high-level radioactive wastes (HLW). In support of this program, preliminary studies were carried out on sorption of cesium, strontium, technetium, neptunium, and uranium onto Chattanooga (Upper Dowelltown), Pierre, Green River Formation, Nolichucky, and Pumpkin Valley Shales under oxic conditions (air present). Three simulated groundwaters were used. One of the groundwaters was a synthetic brine made up to simulate highly saline groundwaters in the Pumpkin Valley Shale. The second was a 100/1 dilution of thismore » groundwater and the third was 0.03 M NaHCO/sub 3/. Moderate to significant sorption was observed under most conditions for all of the tested radionuclides except technetium. Moderate technetium sorption occurred on Upper Dowelltown Shale, and although technetium sorption was low on the other shales, it was higher than expected for Tc(VII), present as the anion TcO/sub 4//sup -/. Little sorption of strontium onto the shales was observed from the concentrated saline groundwater. These data can be used in a generic fashion to help assess the sorption characteristics of shales in support of a national survey. 10 refs., 4 figs., 23 tabs.« less

  12. Rhenium volatilisation as caesium perrhenate from simulated vitrified high level waste from a melter crucible

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, T.A.; Short, R.J.; Gribble, N.R.

    2013-07-01

    The Waste Vitrification Plant (WVP) converts Highly Active Liquor (HAL) from spent nuclear fuel reprocessing into a stable vitrified product. Recently WVP have been experiencing accumulation of solids in their primary off gas (POG) system leading to potential blockages. Chemical analysis of the blockage material via Laser Induced Breakdown Spectroscopy (LIBS) has shown it to exclusively consist of caesium, technetium and oxygen. The solids are understood to be caesium pertechnetate (CsTcO{sub 4}), resulting from the volatilisation of caesium and technetium from the high level waste glass melt. Using rhenium as a chemical surrogate for technetium, a series of full scalemore » experiments have been performed in order to understand the mechanism of rhenium volatilisation as caesium perrhenate (CsReO{sub 4}), and therefore technetium volatilisation as CsTcO{sub 4}. These experiments explored the factors governing volatilisation rates from the melt, potential methods of minimising the amount of volatilisation, and various strategies for mitigating the deleterious effects of the volatile material on the POG. This paper presents the results from those experiments, and discusses potential methods to minimise blockages that can be implemented on WVP, so that the frequency of the CsTcO{sub 4} blockages can be reduced or even eradicated altogether. (authors)« less

  13. 55. VIEW OF ROASTER ADDITION FROM NORTH. ELEVATOR/ORE BIN ADDITION ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    55. VIEW OF ROASTER ADDITION FROM NORTH. ELEVATOR/ORE BIN ADDITION TO RIGHT (WEST) WITH BAKER COOLER IN FRONT. - Bald Mountain Gold Mill, Nevada Gulch at head of False Bottom Creek, Lead, Lawrence County, SD

  14. Polylactides in additive biomanufacturing.

    PubMed

    Poh, Patrina S P; Chhaya, Mohit P; Wunner, Felix M; De-Juan-Pardo, Elena M; Schilling, Arndt F; Schantz, Jan-Thorsten; van Griensven, Martijn; Hutmacher, Dietmar W

    2016-12-15

    New advanced manufacturing technologies under the alias of additive biomanufacturing allow the design and fabrication of a range of products from pre-operative models, cutting guides and medical devices to scaffolds. The process of printing in 3 dimensions of cells, extracellular matrix (ECM) and biomaterials (bioinks, powders, etc.) to generate in vitro and/or in vivo tissue analogue structures has been termed bioprinting. To further advance in additive biomanufacturing, there are many aspects that we can learn from the wider additive manufacturing (AM) industry, which have progressed tremendously since its introduction into the manufacturing sector. First, this review gives an overview of additive manufacturing and both industry and academia efforts in addressing specific challenges in the AM technologies to drive toward AM-enabled industrial revolution. After which, considerations of poly(lactides) as a biomaterial in additive biomanufacturing are discussed. Challenges in wider additive biomanufacturing field are discussed in terms of (a) biomaterials; (b) computer-aided design, engineering and manufacturing; (c) AM and additive biomanufacturing printers hardware; and (d) system integration. Finally, the outlook for additive biomanufacturing was discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1994-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  16. Process for the recovery of strontium from acid solutions

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1992-03-31

    The invention is a process for selectively extracting strontium and technetium values from aqueous nitric acid waste solutions containing these and other fission product values. The extractant is a macrocyclic polyether in a diluent which is insoluble in water, but which will itself dissolve a small amount of water. The process will extract strontium and technetium values from nitric acid solutions which are up to 6 molar in nitric acid. 5 figs.

  17. Method for liquid chromatographic extraction of strontium from acid solutions

    DOEpatents

    Horwitz, E. Philip; Dietz, Mark L.

    1992-01-01

    A method and apparatus for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column is described. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water.

  18. Additive Manufacturing Infrared Inspection

    NASA Technical Reports Server (NTRS)

    Gaddy, Darrell; Nettles, Mindy

    2015-01-01

    The Additive Manufacturing Infrared Inspection Task started the development of a real-time dimensional inspection technique and digital quality record for the additive manufacturing process using infrared camera imaging and processing techniques. This project will benefit additive manufacturing by providing real-time inspection of internal geometry that is not currently possible and reduce the time and cost of additive manufactured parts with automated real-time dimensional inspections which deletes post-production inspections.

  19. Applications and interpretation of krypton 81m ventilation/technetium 99m macroaggregate perfusion lung scanning in childhood

    NASA Astrophysics Data System (ADS)

    Davies, Hugh Trevor Frimston

    Radionuclide ventilation perfusion lung scans now play an important part in the investigation of paediatric lung disease, providing a safe, noninvasive assessment of regional lung function in children with suspected pulmonary disease. In paediatric practice the most suitable radionuclides are Krypton 81m (Kr81m) and Technetium 99m (Tc99m), which are jointly used in the Kr81m ventilation/Tc99m macroaggregate perfusion lung scan (V/Q lung scan). The Kr81m ventilation scan involves a low radiation dose, requires little or no subject cooperation and because of the very short half life of Kr81m (13 seconds) the steady state image acquired during continuous inhalation of the radionuclide is considered to reflect regional distribution of ventilation. It is now the most important noninvasive method available for the investigation of the regional abnormalities of ventilation characteristic of many congenital and acquired paediatric respiratory diseases, such as diaphragmatic hernia, pulmonary sequestration, bronchopulmonary dysplasia, foreign body inhalation and bronchiectasis. It improves diagnostic accuracy, aids clinical decision making and is used to monitor the progress of disease and response to therapy. Theoretical analysis of the steady state Kr81m ventilation image suggests that it may only reflect regional ventilation when specific ventilation (ventilation per unit volume of lung) is within or below the normal adult range (1-3 L/L/min). At higher values such as those seen in neonates and infants (8-15 L/L/min) Kr81m activity may reflect regional lung volume rather than ventilation, a conclusion supported by the studies of Ciofetta et al. There is some controversy on this issue as animal studies have demonstrated that the Kr81m image reflects ventilation over a much wider range of specific ventilation (up to 13 L/L/min). A clinical study of sick infants and very young children is in agreement with this animal work and suggests that the steady state Kr81m image

  20. Techniques for Loading Technetium-99m and Rhenium-186/188 Radionuclides into Preformed Liposomes for Diagnostic Imaging and Radionuclide Therapy.

    PubMed

    Goins, Beth; Bao, Ande; Phillips, William T

    2017-01-01

    Liposomes can serve as carriers of radionuclides for diagnostic imaging and therapeutic applications. Herein, procedures are outlined for radiolabeling liposomes with the gamma-emitting radionuclide, technetium-99m ( 99m Tc), for noninvasive detection of disease and for monitoring the pharmacokinetics and biodistribution of liposomal drugs, and/or with therapeutic beta-emitting radionuclides, rhenium-186/188 ( 186/188 Re), for radionuclide therapy. These efficient and practical liposome radiolabeling methods use a post-labeling mechanism to load 99m Tc or 186/188 Re into preformed liposomes prepared in advance of the labeling procedure. For all liposome radiolabeling methods described, a lipophilic chelator is used to transport 99m Tc or 186/188 Re across the lipid bilayer of the preformed liposomes. Once within the liposome interior, the pre-encapsulated glutathione or ammonium sulfate (pH) gradient provides for stable entrapment of the 99m Tc and 186/188 Re within the liposomes. In the first method, 99m Tc is transported across the lipid bilayer by the lipophilic chelator, hexamethylpropyleneamine oxime (HMPAO) and 99m Tc-HMPAO becomes trapped by interaction with the pre-encapsulated glutathione within the liposomes. In the second method, 99m Tc or 186/188 Re is transported across the lipid bilayer by the lipophilic chelator, N,N-bis(2-mercaptoethyl)-N',N'-diethylethylenediamine (BMEDA), and 99m Tc-BMEDA or 186/188 Re-BMEDA becomes trapped by interaction with pre-encapsulated glutathione within the liposomes. In the third method, an ammonium sulfate (pH) gradient loading technique is employed using liposomes with an extraliposomal pH of 7.4 and an interior pH of 5.1. BMEDA, which is lipophilic at pH 7.4, serves as a lipophilic chelator for 99m Tc or 186/188 Re to transport the radionuclides across the lipid bilayer. Once within the more acidic liposome interior, 99m Tc/ 186/188 Re-BMEDA complex becomes protonated and more hydrophilic, which results in stable

  1. 40 CFR 79.31 - Additives.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Additives. 79.31 Section 79.31... OF FUELS AND FUEL ADDITIVES Designation of Fuels and Additives § 79.31 Additives. (a) All additives... persons or property on a street or highway. For purposes of this registration, however, additives...

  2. 40 CFR 79.31 - Additives.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Additives. 79.31 Section 79.31... OF FUELS AND FUEL ADDITIVES Designation of Fuels and Additives § 79.31 Additives. (a) All additives... persons or property on a street or highway. For purposes of this registration, however, additives...

  3. 40 CFR 79.31 - Additives.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Additives. 79.31 Section 79.31... OF FUELS AND FUEL ADDITIVES Designation of Fuels and Additives § 79.31 Additives. (a) All additives... persons or property on a street or highway. For purposes of this registration, however, additives...

  4. 40 CFR 79.31 - Additives.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Additives. 79.31 Section 79.31... OF FUELS AND FUEL ADDITIVES Designation of Fuels and Additives § 79.31 Additives. (a) All additives... persons or property on a street or highway. For purposes of this registration, however, additives...

  5. 40 CFR 79.31 - Additives.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Additives. 79.31 Section 79.31... OF FUELS AND FUEL ADDITIVES Designation of Fuels and Additives § 79.31 Additives. (a) All additives... persons or property on a street or highway. For purposes of this registration, however, additives...

  6. Immobilization of 99-Technetium (VII) by Fe(II)-Goethite and Limited Reoxidation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Chang, Hyun-Shik; Icenhower, Jonathan P.

    2011-05-04

    Synthesized goethite was successfully used with addition of Fe(II) to sequester Tc present in both deionized water and simulated off-gas scrubber waste solutions. Pertechnetate concentration in solution decreased immediately when the pH was raised above 7 by addition of sodium hydroxide. Removal of Tc(VII) from solution occurred most likely as a result of heterogeneous surface-catalyzed reduction to Tc(IV) and subsequent co-precipitation onto the goethite. The final Tc-bearing solid was identified as goethite-dominated Fe(III)-(oxy)hydroxide based on XRD analysis, confirming the widespread observation of its characteristic acicular habit by TEM/SEM images. Analysis of the solid precipitate by XAFS showed that the dominantmore » oxidation state of Tc was Tc(IV) and was in octahedral coordination with Tc-O, Fe-O, and Tc-Fe bond distances that are consistent with direct substitution of Tc for Fe in the goethite structure. In some experiments the final Tc-goethite product was subsequently armored with additional layers of freshly precipitated goethite. Successful incorporation of Tc(IV) within the goethite mineral lattice and subsequent goethite armoring can limit re-oxidation of Tc(IV) and its subsequent release from Tc-goethite waste forms, even when the final product is placed in oxidizing environments that typify shallow waste burial facilities.« less

  7. Detection of intestinal obstruction by radionuclide scan: case report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chaudhuri, T.K.

    1976-11-01

    The value of /sup 99m/Technetium-pertechnetate abdomen scan has recently been established in the diagnosis of Meckel's diverticulum, intussusception, and inflamed appendix. The purpose of this paper is to report a case with small intestinal obstruction secondary to fibrous adhesions which resulted from a previous surgery, in whom a /sup 99m/Technetium-pertechnetate abdomen scan showed increased radionuclide concentration in the area of dilated loop of bowel proximal to the site of obstruction.

  8. Liquid chromatographic extraction medium

    DOEpatents

    Horwitz, E.P.; Dietz, M.L.

    1994-09-13

    A method and apparatus are disclosed for extracting strontium and technetium values from biological, industrial and environmental sample solutions using a chromatographic column. An extractant medium for the column is prepared by generating a solution of a diluent containing a Crown ether and dispersing the solution on a resin substrate material. The sample solution is highly acidic and is introduced directed to the chromatographic column and strontium or technetium is eluted using deionized water. 1 fig.

  9. Phosphazene additives

    DOEpatents

    Harrup, Mason K; Rollins, Harry W

    2013-11-26

    An additive comprising a phosphazene compound that has at least two reactive functional groups and at least one capping functional group bonded to phosphorus atoms of the phosphazene compound. One of the at least two reactive functional groups is configured to react with cellulose and the other of the at least two reactive functional groups is configured to react with a resin, such as an amine resin of a polycarboxylic acid resin. The at least one capping functional group is selected from the group consisting of a short chain ether group, an alkoxy group, or an aryloxy group. Also disclosed are an additive-resin admixture, a method of treating a wood product, and a wood product.

  10. Role of nuclear medicine in clinical urology and nephrology

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blaufox, M.D.; Fine, E.; Lee, H.B.

    The application of radionuclide studies to nephrologic and urologic practice has reached a measurable degree of maturity during the past several years. In spite of this, the utilization of these techniques in many institutions in the United States continues to be far less frequent than one would expect from the clinical advantages. The aim of this editorial is to try to place the role of nuclear medicine in urology and nephrology in perspective. At the present time, in spite of the large number of renal agents that have been developed, there is no practical ideal radiopharmaceutical that can serve asmore » a universal agent. Arbitrarily, one may reduce the chief armamentarium to only four radiopharmaceuticals; technetium-99m DTPA, I-131 OIH (orthoiodohippurate), technetium-99m glucoheptonate and technetium-99m DMSA. These agents are discussed with their relative advantages and disadvantages.« less

  11. Sodalite as a vehicle to increase Re retention in waste glass simulant during vitrification

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Riley, Brian J.; Parker, Kent E.

    Technetium retention during Hanford waste vitrification can be increased by inhibiting technetium volatility from the waste glass melter. Incorporating technetium into a mineral phase, such as sodalite, is one way to achieve this. Rhenium-bearing sodalite was tested as a vehicle to transport perrhenate (ReO4-), a nonradioactive surrogate for pertechnetate (TcO4-), into high-level (HLW) and low-activity waste (LAW) glasses. After melting feeds of these two glasses, the retention of rhenium was measured and compared with the rhenium retention in glass prepared from a feed containing Re2O7 as a standard. The rhenium retention was 21% higher for HLW glass and 85% highermore » for LAW glass when added to samples in the form of sodalite as opposed to when it was added as Re2O7, demonstrating the efficacy of this type of an approach.« less

  12. Increased technetium-99 m hydroxy diphosphonate soft tissue uptake on bone scintigraphy in chronic kidney disease patients with secondary hyperparathyroidism: correlation with hyperphosphataemia.

    PubMed

    Enevoldsen, Lotte Hahn; Heaf, James; Højgaard, Liselotte; Zerahn, Bo; Hasbak, Philip

    2017-03-01

    In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and/or hyperphosphataemia. As human vascular smooth muscle cells produce hydroxyapatite during cell culture with increased phosphate levels and as Tc-99 m-HDP/MDP primarily binds to hydroxyapatite, we hypothesized that soft tissue accumulation would be found in patients with hyperphosphataemia. We identified 63 CKD patients diagnosed with secondary hyperparathyroidism admitted for Tc-99 m-HDP bone scan. Baseline characteristics and mean concentrations of biochemical markers (including P-calcium and P-phosphate) taken 0-3 months prior to the bone scans were collected. Soft tissue uptake was detected on bone scans in 37 of 63 (59%) patients. Primary locations were in the heart (27/37 = 73%), muscles (12/37 = 32%), lung (9/37 = 24%) and gastrointestinal tract (6/37 = 16%), and 13 of 37 (35%) patients had simultaneous uptake in more than one location. Regarding biochemical markers, patients with soft tissue uptake only differed from patients without in terms of plasma phosphate levels (1·95 ± 0·15 (n = 37) versus 1·27 ± 0·08 (n = 26), P = 0·0012). All patients with myocardial uptake (n = 27) had a coronary arteriography-verified history of coronary artery disease (CAD), whereas CAD was only present in six of the 36 patients without myocardial uptake. In conclusion, dialysis-treated CKD patients with secondary hyperparathyroidism have a high incidence of soft tissue uptake, and this finding is strongly correlated with elevated phosphate, but not calcium values. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  13. Biliary excretion of technetium-99m-sestamibi in wild-type dogs and in dogs with intrinsic (ABCB1-1Delta mutation) and extrinsic (ketoconazole treated) P-glycoprotein deficiency.

    PubMed

    Coelho, J C; Tucker, R; Mattoon, J; Roberts, G; Waiting, D K; Mealey, K L

    2009-10-01

    P-glycoprotein (P-gp), the product of ABCB1 gene, is thought to play a role in the biliary excretion of a variety of drugs, but specific studies in dogs have not been performed. Because a number of endogenous (ABCB1 polymorphisms) and exogenous (pharmacological P-gp inhibition) factors can interfere with normal P-gp function, a better understanding of P-gp's role in biliary drug excretion is crucial in preventing adverse drug reactions and drug-drug interactions in dogs. The objectives of this study were to compare biliary excretion of technetium-99m-sestamibi ((99m)Tc-MIBI), a radio-labelled P-gp substrate, in wild-type dogs (ABCB1 wild/wild), and dogs with intrinsic and extrinsic deficiencies in P-gp function. Dogs with intrinsic P-gp deficiency included ABCB1 mut/mut dogs, and dogs with presumed intermediate P-gp phenotype (ABCB1 mut/wild). Dogs with extrinsic P-gp deficiency were considered to be ABCB1 wild/wild dogs treated with the P-gp inhibitor ketoconazole (5 mg/kg PO q12h x 9 doses). Results from this study indicate that ABCB1 mut/mut dogs have significantly decreased biliary excretion of (99m)Tc-MIBI compared with ABCB1 wild/wild dogs. Treatment with ketoconazole significantly decreased biliary excretion of (99m)Tc-MIBI in ABCB1 wild/wild dogs. P-gp appears to play an important role in the biliary excretion of (99m)Tc-MIBI in dogs. It is likely that concurrent administration of a P-gp inhibitor such as ketoconazole will decrease P-gp-mediated biliary excretion of other substrate drugs as well.

  14. Drilling mud additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Roemer, P.; Downhour, R. Jr.

    1970-06-30

    A drilling mud additive prepared from farinaceous material contains relatively high gluten and fat contents and has between 30 and 40% water soluble solids on a dry basis. The product is particularly useful in rotary drilling as an additive to the drilling mud to inhibit water loss. The key to achieving the desired product is pretreatment of the raw flour and control of moisture. (2 claims)

  15. Bismuth Infusion of ABS Enables Additive Manufacturing of Complex Radiological Phantoms and Shielding Equipment.

    PubMed

    Ceh, Justin; Youd, Tom; Mastrovich, Zach; Peterson, Cody; Khan, Sarah; Sasser, Todd A; Sander, Ian M; Doney, Justin; Turner, Clark; Leevy, W Matthew

    2017-02-24

    Radiopacity is a critical property of materials that are used for a range of radiological applications, including the development of phantom devices that emulate the radiodensity of native tissues and the production of protective equipment for personnel handling radioactive materials. Three-dimensional (3D) printing is a fabrication platform that is well suited to creating complex anatomical replicas or custom labware to accomplish these radiological purposes. We created and tested multiple ABS (Acrylonitrile butadiene styrene) filaments infused with varied concentrations of bismuth (1.2-2.7 g/cm³), a radiopaque metal that is compatible with plastic infusion, to address the poor gamma radiation attenuation of many mainstream 3D printing materials. X-ray computed tomography (CT) experiments of these filaments indicated that a density of 1.2 g/cm³ of bismuth-infused ABS emulates bone radiopacity during X-ray CT imaging on preclinical and clinical scanners. ABS-bismuth filaments along with ABS were 3D printed to create an embedded human nasocranial anatomical phantom that mimicked radiological properties of native bone and soft tissue. Increasing the bismuth content in the filaments to 2.7 g/cm³ created a stable material that could attenuate 50% of 99m Technetium gamma emission when printed with a 2.0 mm wall thickness. A shielded test tube rack was printed to attenuate source radiation as a protective measure for lab personnel. We demonstrated the utility of novel filaments to serve multiple radiological purposes, including the creation of anthropomorphic phantoms and safety labware, by tuning the level of radiation attenuation through material customization.

  16. Cyclopentadienyl Rhenium (Technetium) Tricarbonyl Complexes Integrated in Estrogen Receptor Ligands for ER+ Tumor Imaging

    DTIC Science & Technology

    2006-10-01

    determined by imaging correlate well with those determined by immunoassay methods on surgical biopsies. Because of the short half-life of fluorine -18, this...immunoassay methods on surgical biopsies. Currently, the most effective ER imaging agent is a fluorine -18 labeled estrogen. However, because of the short...substituent to the central pentacycle, including nucleophilic addition of organometallic reagents, addition of electrophiles to the cyclopentadiene

  17. Food additives

    MedlinePlus

    ... or natural. Natural food additives include: Herbs or spices to add flavor to foods Vinegar for pickling ... Certain colors improve the appearance of foods. Many spices, as well as natural and man-made flavors, ...

  18. Techniques for loading technetium-99m and rhenium-186/188 radionuclides into pre-formed liposomes for diagnostic imaging and radionuclide therapy.

    PubMed

    Goins, Beth; Bao, Ande; Phillips, William T

    2010-01-01

    Liposomes can serve as carriers of radionuclides for diagnostic imaging and therapeutic applications. Herein, procedures are outlined for radiolabeling liposomes with the gamma-emitting radionuclide, technetium-99m ((99m)Tc), for non-invasive detection of disease and for monitoring the pharmacokinetics and biodistribution of liposomal drugs, and/or with therapeutic beta-emitting radionuclides, rhenium-186/188 ((186/188)Re), for radionuclide therapy. These efficient and practical liposome radiolabeling methods use a post-labeling mechanism to load (99m)Tc or (186/188)Re into pre-formed liposomes prepared in advance of the labeling procedure. For all liposome radiolabeling methods described, a lipophilic chelator is used to transport (99m)Tc or (186/188)Re across the lipid bilayer of the pre-formed liposomes. Once within the liposome interior, the pre-encapsulated glutathione or ammonium sulfate (pH) gradient provides for stable entrapment of the (99m)Tc and (186/188)Re within the liposomes. In the first method, (99m)Tc is transported across the lipid bilayer by the lipophilic chelator, hexamethylpropyleneamine oxime (HMPAO) and (99m)Tc-HMPAO becomes trapped by interaction with the pre-encapsulated glutathione within the liposomes. In the second method, (99m)Tc or (186/188)Re is transported across the lipid bilayer by the lipophilic chelator, N,N-bis(2-mercaptoethyl)-N',N'-diethylethylenediamine (BMEDA), and (99m)Tc-BMEDA or (186/188)Re-BMEDA becomes trapped by interaction with pre-encapsulated glutathione within the liposomes. In the third method, an ammonium sulfate (pH) gradient loading technique is employed using liposomes with an extraliposomal pH of 7.4 and an interior pH of 5.1. BMEDA, which is lipophilic at pH 7.4, serves as a lipophilic chelator for (99m)Tc or (186/188)Re to transport the radionuclides across the lipid bilayer. Once within the more acidic liposome interior, (99m)Tc/(186/188)Re-BMEDA complex becomes protonated and more hydrophilic, which

  19. Bone scanning in severe external otitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Levin, W.J.; Shary, J.H. 3d.; Nichols, L.T.

    1986-11-01

    Technetium99 Methylene Diphosphate bone scanning has been considered an early valuable tool to diagnose necrotizing progressive malignant external otitis. However, to our knowledge, no formal studies have actually compared bone scans of otherwise young, healthy patients with severe external otitis to scans of patients with clinical presentation of malignant external otitis. Twelve patients with only severe external otitis were studied with Technetium99 Diphosphate and were compared to known cases of malignant otitis. All scans were evaluated by two neuroradiologists with no prior knowledge of the clinical status of the patients. Nine of the 12 patients had positive bone scans withmore » many scans resembling those reported with malignant external otitis. Interestingly, there was no consistent correlation between the severity of clinical presentation and the amount of Technetium uptake. These findings suggest that a positive bone scan alone should not be interpreted as indicative of malignant external otitis.« less

  20. Additive Manufacturing Infrared Inspection

    NASA Technical Reports Server (NTRS)

    Gaddy, Darrell

    2014-01-01

    Additive manufacturing is a rapid prototyping technology that allows parts to be built in a series of thin layers from plastic, ceramics, and metallics. Metallic additive manufacturing is an emerging form of rapid prototyping that allows complex structures to be built using various metallic powders. Significant time and cost savings have also been observed using the metallic additive manufacturing compared with traditional techniques. Development of the metallic additive manufacturing technology has advanced significantly over the last decade, although many of the techniques to inspect parts made from these processes have not advanced significantly or have limitations. Several external geometry inspection techniques exist such as Coordinate Measurement Machines (CMM), Laser Scanners, Structured Light Scanning Systems, or even traditional calipers and gages. All of the aforementioned techniques are limited to external geometry and contours or must use a contact probe to inspect limited internal dimensions. This presentation will document the development of a process for real-time dimensional inspection technique and digital quality record of the additive manufacturing process using Infrared camera imaging and processing techniques.

  1. 37 CFR 1.776 - Calculation of patent term extension for a food additive or color additive.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... extension for a food additive or color additive. 1.776 Section 1.776 Patents, Trademarks, and Copyrights... Calculation of patent term extension for a food additive or color additive. (a) If a determination is made pursuant to § 1.750 that a patent for a food additive or color additive is eligible for extension, the term...

  2. 37 CFR 1.776 - Calculation of patent term extension for a food additive or color additive.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... extension for a food additive or color additive. 1.776 Section 1.776 Patents, Trademarks, and Copyrights... Calculation of patent term extension for a food additive or color additive. (a) If a determination is made pursuant to § 1.750 that a patent for a food additive or color additive is eligible for extension, the term...

  3. 37 CFR 1.776 - Calculation of patent term extension for a food additive or color additive.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... extension for a food additive or color additive. 1.776 Section 1.776 Patents, Trademarks, and Copyrights... Calculation of patent term extension for a food additive or color additive. (a) If a determination is made pursuant to § 1.750 that a patent for a food additive or color additive is eligible for extension, the term...

  4. 37 CFR 1.776 - Calculation of patent term extension for a food additive or color additive.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... extension for a food additive or color additive. 1.776 Section 1.776 Patents, Trademarks, and Copyrights... Calculation of patent term extension for a food additive or color additive. (a) If a determination is made pursuant to § 1.750 that a patent for a food additive or color additive is eligible for extension, the term...

  5. 37 CFR 1.776 - Calculation of patent term extension for a food additive or color additive.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... extension for a food additive or color additive. 1.776 Section 1.776 Patents, Trademarks, and Copyrights... Calculation of patent term extension for a food additive or color additive. (a) If a determination is made pursuant to § 1.750 that a patent for a food additive or color additive is eligible for extension, the term...

  6. Additive manufacturing of optical components

    NASA Astrophysics Data System (ADS)

    Heinrich, Andreas; Rank, Manuel; Maillard, Philippe; Suckow, Anne; Bauckhage, Yannick; Rößler, Patrick; Lang, Johannes; Shariff, Fatin; Pekrul, Sven

    2016-08-01

    The development of additive manufacturing methods has enlarged rapidly in recent years. Thereby, the work mainly focuses on the realization of mechanical components, but the additive manufacturing technology offers a high potential in the field of optics as well. Owing to new design possibilities, completely new solutions are possible. This article briefly reviews and compares the most important additive manufacturing methods for polymer optics. Additionally, it points out the characteristics of additive manufactured polymer optics. Thereby, surface quality is of crucial importance. In order to improve it, appropriate post-processing steps are necessary (e.g. robot polishing or coating), which will be discussed. An essential part of this paper deals with various additive manufactured optical components and their use, especially in optical systems for shape metrology (e.g. borehole sensor, tilt sensor, freeform surface sensor, fisheye lens). The examples should demonstrate the potentials and limitations of optical components produced by additive manufacturing.

  7. Axillary lymph node uptake of technetium-99m-MDP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ongseng, F.; Goldfarb, C.R.; Finestone, H.

    We sought to determine the frequency and significance of axillary lymph node visualization on bone scans performed with diphosphonates. Consecutive {sup 99m}Tc-methylene diphosphonate ({sup 99m}Tc-MDP) bone scans (2435) were inspected for axillary soft-tissue uptake. In positive cases, the results of physical examination, correlative imaging studies and serial bone scans were recorded, as was the site of venipuncture. Forty-eight studies (2%) showed axillary uptake ipsilateral to the injection site. Extravasation of tracer, documented by focal activity near the injection site, was present in every case. There was no association with axillary adenopathy, mass, induration of radiographically visible calcification. On some images,more » foci adjacent to the axilla were superimposed on the rib, scapula, or humerus. The bone-to-background ratio was frequently reduced; repeat imaging after 1-2 hr usually improved osseous detail. Ipsilateral axillary lymph node visualization due to extravasation of {sup 99m}Tc-MDP is frequently associated with additional foci superimposed on osseous structures simulating pathology. Delayed skeletal uptake is common in such cases and necessitates a greater time interval between injection and imaging. 7 refs., 3 figs.« less

  8. Corrosion Behavior of Nuclear Waste Storage Canister Materials

    NASA Astrophysics Data System (ADS)

    Grant, John

    The nature of interaction of mild steel nuclear waste storage containers with technetium ions is not fully known. Technetium is formed during nuclear processing and some of this technetium has leaked at the Hanford nuclear waste storage site in Washington State. It is often found as highly oxidized pertechnetate (TeO4-) anions at these storage sites which also happen to be highly alkaline and contain a significant amount of nitrate. Theoretically, pertechnetate anions can act as electron acceptors and interact with the mild steel containers and accelerate the oxidation (corrosion) of steel. It is of interest to identify if pertechnetate anions pose a corrosion hazard to the mild steel nuclear waste storage tanks, under the conditions of the storage sites, as that can accelerate the degradation of the tanks and lead to further contamination. In this thesis, the interaction of two relevant container materials, namely, steel alloys A285 and A537 with a technetium surrogate, rhenium was studied. Perrhenate was used as an analog for pertechnetate. As all isotopes of technetium are radioactive, rhenium was chosen as the experimental surrogate due to its chemical similarity to technetium. Electrochemical behavior was evaluated using potentiodynamic polarization tests, and the surface morphology was studied using optical microscopy and scanning electron microscopy. Potentiodynamic polarization tests were conducted in 1.0M NaNO3 + 0.1M NaOH and 1.0M NaNO3 + 0.1M NaOH + 0.02M NaReO4. Tests were performed at three different temperatures, namely, (i) room temperature, (ii) 50°C and (iii) 80°C to study the effect of higher temperatures found in the storage sites. Corrosion current, corrosion potential, anodic and cathodic Tafel slopes, polarization resistance and corrosion rates were obtained from electrochemical testing and evaluated. Increasing temperatures was found to lead to increasing corrosion rates for all samples. The data also revealed increased corrosion from

  9. Reduction of Pertechnetate By Acetohydroxamic Acid: Formation of [tc**II(NO)(AHA)(2)(H(2)O)]**+ And Implications for the UREX Process

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gong, C.-M.S.; Lukens, W.W.; Poineau, F.

    2009-05-18

    Reductive nitrosylation and complexation of ammonium pertechnetate by acetohydroxamic acid has been achieved in aqueous nitric and perchloric acid solutions. The kinetics of the reaction depend on the relative concentrations of the reaction components and are accelerated at higher temperatures. The reaction does not occur unless conditions are acidic. Analysis of the X-ray absorption fine structure spectroscopic data is consistent with a pseudo-octahedral geometry and the linear Tc-N-O bond typical of technetium nitrosyl compounds, and electron spin resonance spectroscopy is consistent with a d{sup 5} Tc(II) nitrosyl complex. The nitrosyl source is generally AHA, but it may be augmented bymore » some products of the reaction with nitric acid. The resulting low-valency trans-aquonitrosyl(diacetohydroxamic)-technetium(II) complex ([Tc{sup II}(NO)(AHA){sub 2}H{sub 2}O]{sup +}, 1) is highly soluble in water, extremely hydrophilic, and is not extracted by tri-n-butylphosphate in a dodecane diluent. Its extraction properties are not pH-dependent: potentiometric-spectrophotometric titration studies indicate a single species from pH 4 down to -0.6 (calculated). This molecule is resistant to oxidation by H{sub 2}O{sub 2}, even at high pH, and can undergo substitution to form other technetium nitrosyl complexes. The potential formation of 1 during reprocessing may strongly impact the fate of technetium in the nuclear fuel cycle.« less

  10. VIEW TO NORTHEAST OF c19441950 c19441950 POSTU.S. RADIUM ADDITION ADDITIONS ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    VIEW TO NORTHEAST OF c1944-1950 c1944-1950 POST-U.S. RADIUM ADDITION ADDITIONS TO PAINT APPLICATION BUILDING (RIGHT) AND CRYSTALLIZATION LABORATORY (LEFT) - United States Radium Corporation, 422-432 Alden Street, Orange, Essex County, NJ

  11. Incorporation of additives into polymers

    DOEpatents

    McCleskey, T. Mark; Yates, Matthew Z.

    2003-07-29

    There has been invented a method for incorporating additives into polymers comprising: (a) forming an aqueous or alcohol-based colloidal system of the polymer; (b) emulsifying the colloidal system with a compressed fluid; and (c) contacting the colloidal polymer with the additive in the presence of the compressed fluid. The colloidal polymer can be contacted with the additive by having the additive in the compressed fluid used for emulsification or by adding the additive to the colloidal system before or after emulsification with the compressed fluid. The invention process can be carried out either as a batch process or as a continuous on-line process.

  12. QSAR prediction of additive and non-additive mixture toxicities of antibiotics and pesticide.

    PubMed

    Qin, Li-Tang; Chen, Yu-Han; Zhang, Xin; Mo, Ling-Yun; Zeng, Hong-Hu; Liang, Yan-Peng

    2018-05-01

    Antibiotics and pesticides may exist as a mixture in real environment. The combined effect of mixture can either be additive or non-additive (synergism and antagonism). However, no effective predictive approach exists on predicting the synergistic and antagonistic toxicities of mixtures. In this study, we developed a quantitative structure-activity relationship (QSAR) model for the toxicities (half effect concentration, EC 50 ) of 45 binary and multi-component mixtures composed of two antibiotics and four pesticides. The acute toxicities of single compound and mixtures toward Aliivibrio fischeri were tested. A genetic algorithm was used to obtain the optimized model with three theoretical descriptors. Various internal and external validation techniques indicated that the coefficient of determination of 0.9366 and root mean square error of 0.1345 for the QSAR model predicted that 45 mixture toxicities presented additive, synergistic, and antagonistic effects. Compared with the traditional concentration additive and independent action models, the QSAR model exhibited an advantage in predicting mixture toxicity. Thus, the presented approach may be able to fill the gaps in predicting non-additive toxicities of binary and multi-component mixtures. Copyright © 2018 Elsevier Ltd. All rights reserved.

  13. ADDITIVITY ASSESSMENT OF TRIHALOMETHANE MIXTURES BY PROPORTIONAL RESPONSE ADDITION

    EPA Science Inventory

    If additivity is known or assumed, the toxicity of a chemical mixture may be predicted from the dose response curves of the individual chemicals comprising the mixture. As single chemical data are abundant and mixture data sparse, mixture risk methods that utilize single chemical...

  14. Co-occurring nonnative woody shrubs have additive and non-additive soil legacies.

    PubMed

    Kuebbing, Sara E; Patterson, Courtney M; Classen, Aimée T; Simberloff, Daniel

    2016-09-01

    To maximize limited conservation funds and prioritize management projects that are likely to succeed, accurate assessment of invasive nonnative species impacts is essential. A common challenge to prioritization is a limited knowledge of the difference between the impacts of a single nonnative species compared to the impacts of nonnative species when they co-occur, and in particular predicting when impacts of co-occurring nonnative species will be non-additive. Understanding non-additivity is important for management decisions because the management of only one co-occurring invader will not necessarily lead to a predictable reduction in the impact or growth of the other nonnative plant. Nonnative plants are frequently associated with changes in soil biotic and abiotic characteristics, which lead to plant-soil interactions that influence the performance of other species grown in those soils. Whether co-occurring nonnative plants alter soil properties additively or non-additively relative to their effects on soils when they grow in monoculture is rarely addressed. We use a greenhouse plant-soil feedback experiment to test for non-additive soil impacts of two common invasive nonnative woody shrubs, Lonicera maackii and Ligustrum sinense, in deciduous forests of the southeastern United States. We measured the performance of each nonnative shrub, a native herbaceous community, and a nonnative woody vine in soils conditioned by each shrub singly or together in polyculture. Soils conditioned by both nonnative shrubs had non-additive impacts on native and nonnative performance. Root mass of the native herbaceous community was 1.5 times lower and the root mass of the nonnative L. sinense was 1.8 times higher in soils conditioned by both L. maackii and L. sinense than expected based upon growth in soils conditioned by either shrub singly. This result indicates that when these two nonnative shrubs co-occur, their influence on soils disproportionally favors persistence

  15. Enhancing antioxidant activity of sesamol at frying temperature by addition of additives through reducing volatility

    USDA-ARS?s Scientific Manuscript database

    Additives were evaluated to investigate their effects on volatility of sesamol at frying temperature with the hypothesis that the interaction between an additive and sesamol would reduce sesamol volatility. Twenty-two additive:sesamol combinations were examined by thermogravimetric analysis (TGA) un...

  16. 76 FR 41687 - Food Additives Permitted for Direct Addition to Food for Human Consumption; Hydroxypropyl Cellulose

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-15

    .... FDA-2010-F-0103] Food Additives Permitted for Direct Addition to Food for Human Consumption... Drug Administration (FDA) is amending the food additive regulations for hydroxypropyl cellulose by..., New York, NY 10006, filed a food additive petition (FAP 0A4780). The petition proposed to amend the...

  17. Additives in plastics.

    PubMed Central

    Deanin, R D

    1975-01-01

    The polymers used in plastics are generally harmless. However, they are rarely used in pure form. In almost all commercial plastics, they are "compounded" with monomeric ingredients to improve their processing and end-use performance. In order of total volume used, these monomeric additives may be classified as follows: reinforcing fibers, fillers, and coupling agents; plasticizers; colorants; stabilizers (halogen stabilizers, antioxidants, ultraviolet absorbers, and biological preservatives); processing aids (lubricants, others, and flow controls); flame retardants, peroxides; and antistats. Some information is already available, and much more is needed, on potential toxicity and safe handling of these additives during processing and manufacture of plastics products. PMID:1175566

  18. Additive Manufactured Product Integrity

    NASA Technical Reports Server (NTRS)

    Waller, Jess; Wells, Doug; James, Steve; Nichols, Charles

    2017-01-01

    NASA is providing key leadership in an international effort linking NASA and non-NASA resources to speed adoption of additive manufacturing (AM) to meet NASA's mission goals. Participants include industry, NASA's space partners, other government agencies, standards organizations and academia. Nondestructive Evaluation (NDE) is identified as a universal need for all aspects of additive manufacturing.

  19. Functional Additive Mixed Models

    PubMed Central

    Scheipl, Fabian; Staicu, Ana-Maria; Greven, Sonja

    2014-01-01

    We propose an extensive framework for additive regression models for correlated functional responses, allowing for multiple partially nested or crossed functional random effects with flexible correlation structures for, e.g., spatial, temporal, or longitudinal functional data. Additionally, our framework includes linear and nonlinear effects of functional and scalar covariates that may vary smoothly over the index of the functional response. It accommodates densely or sparsely observed functional responses and predictors which may be observed with additional error and includes both spline-based and functional principal component-based terms. Estimation and inference in this framework is based on standard additive mixed models, allowing us to take advantage of established methods and robust, flexible algorithms. We provide easy-to-use open source software in the pffr() function for the R-package refund. Simulations show that the proposed method recovers relevant effects reliably, handles small sample sizes well and also scales to larger data sets. Applications with spatially and longitudinally observed functional data demonstrate the flexibility in modeling and interpretability of results of our approach. PMID:26347592

  20. Functional Additive Mixed Models.

    PubMed

    Scheipl, Fabian; Staicu, Ana-Maria; Greven, Sonja

    2015-04-01

    We propose an extensive framework for additive regression models for correlated functional responses, allowing for multiple partially nested or crossed functional random effects with flexible correlation structures for, e.g., spatial, temporal, or longitudinal functional data. Additionally, our framework includes linear and nonlinear effects of functional and scalar covariates that may vary smoothly over the index of the functional response. It accommodates densely or sparsely observed functional responses and predictors which may be observed with additional error and includes both spline-based and functional principal component-based terms. Estimation and inference in this framework is based on standard additive mixed models, allowing us to take advantage of established methods and robust, flexible algorithms. We provide easy-to-use open source software in the pffr() function for the R-package refund. Simulations show that the proposed method recovers relevant effects reliably, handles small sample sizes well and also scales to larger data sets. Applications with spatially and longitudinally observed functional data demonstrate the flexibility in modeling and interpretability of results of our approach.

  1. 77 FR 13009 - Regulation of Fuels and Fuel Additives: Identification of Additional Qualifying Renewable Fuel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-05

    ... ENVIRONMENTAL PROTECTION AGENCY 40 CFR Part 80 [EPA-HQ-OAR-2011-0542; FRL-9642-3] RIN 2060-AR07 Regulation of Fuels and Fuel Additives: Identification of Additional Qualifying Renewable Fuel Pathways Under... of Sec. 80.1426 to identify additional renewable fuel production pathways and pathway components that...

  2. Phenylethynyl Containing Reactive Additives

    NASA Technical Reports Server (NTRS)

    Connell, John W. (Inventor); Smith, Joseph G., Jr. (Inventor); Hergenrother, Paul M. (Inventor)

    2002-01-01

    Phenylethynyl containing reactive additives were prepared from aromatic diamines containing phenylethynyl groups and various ratios of phthalic anhydride and 4-phenylethynylphthalic anhydride in glacial acetic acid to form the imide in one step or in N-methyl-2-pyrrolidi none to form the amide acid intermediate. The reactive additives were mixed in various amounts (10% to 90%) with oligomers containing either terminal or pendent phenylethynyl groups (or both) to reduce the melt viscosity and thereby enhance processability. Upon thermal cure, the additives react and become chemically incorporated into the matrix and effect an increase in crosslink density relative to that of the host resin. This resultant increase in crosslink density has advantageous consequences on the cured resin properties such as higher glass transition temperature and higher modulus as compared to that of the host resin.

  3. Phenylethynyl Containing Reactive Additives

    NASA Technical Reports Server (NTRS)

    Connell, John W. (Inventor); Smith, Joseph G., Jr. (Inventor); Hergenrother, Paul M. (Inventor)

    2002-01-01

    Phenylethynyl containing reactive additives were prepared from aromatic diamine, containing phenylethvnvl groups and various ratios of phthalic anhydride and 4-phenylethynviphthalic anhydride in glacial acetic acid to form the imide in one step or in N-methyl-2-pvrrolidinone to form the amide acid intermediate. The reactive additives were mixed in various amounts (10% to 90%) with oligomers containing either terminal or pendent phenylethynyl groups (or both) to reduce the melt viscosity and thereby enhance processability. Upon thermal cure, the additives react and become chemically incorporated into the matrix and effect an increase in crosslink density relative to that of the host resin. This resultant increase in crosslink density has advantageous consequences on the cured resin properties such as higher glass transition temperature and higher modulus as compared to that of the host resin.

  4. [Safety of food additives in Japan].

    PubMed

    Ito, Sumio

    2011-01-01

    Recently, many accidents relating to food happened in Japan. The consumer's distrust for food, food companies, and the administration is increasing. The consumer especially has an extreme refusal feeling for chemicals such as food additives and agricultural chemicals, and begins to request agricultural chemical-free vegetables and food additive-free food. Food companies also state no agricultural chemicals and no food additives to correspond with consumers' request and aim at differentiating. The food additive is that the Ministry of Health, Labour and Welfare specifies the one that person's health might not be ruined by providing for Food Sanitation Law Article 10 in our country. The standard for food additives and standard for use of food additives are provided according to regulations of Food Sanitation Law Article 11. Therefore, it is thought that the food additive used is safe now. Then, it reports on the procedure and the safety examination, etc. in our country for designation for food additive this time.

  5. 76 FR 47210 - Notices of Filing of Petitions for Food Additives and Color Additives; Relocation in the Federal...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-04

    ...] Notices of Filing of Petitions for Food Additives and Color Additives; Relocation in the Federal Register...) is notifying the public that notices of filing of petitions for food additives and color additives... additive petition approval process for food additives for use in human and animal food. Section 409(b)(5...

  6. Imaging experimental intraabdominal abscesses with 99mTc-PEG liposomes and 99mTc-HYNIC IgG.

    PubMed Central

    Dams, E T; Reijnen, M M; Oyen, W J; Boerman, O C; Laverman, P; Storm, G; van der Meer, J W; Corstens, F H; van Goor, H

    1999-01-01

    OBJECTIVE: To evaluate the accuracy of technetium-99m-labeled polyethylene glycol-coated liposomes (99mTc-PEG liposomes) and technetium-99m-labeled nonspecific human immunoglobulin G (99mTc-HYNIC IgG) for the scintigraphic detection of experimental intraabdominal abscesses in comparison with that of a standard agent, gallium-67 citrate. BACKGROUND: Scintigraphic imaging techniques can be very useful for the rapid and accurate localization of intraabdominal abscesses. Two newly developed radiolabeled agents, 99mTc-PEG liposomes and 99mTc-HYNIC IgG, have shown to be excellent agents for imaging experimental focal infection, but have not yet been studied in the detection of abdominal abscesses. METHODS: Intraabdominal abscesses were induced in 42 rats using the cecal ligation and puncture technique. Seven days later, randomized groups of rats received 99mTc-PEG liposomes, 99mTc-HYNIC IgG, or 67Ga citrate intravenously. The rats were imaged up to 24 hours after the injection. The biodistribution of the radiolabel was determined by counting dissected tissues ex vivo. Macroscopic intraabdominal abnormalities and focal uptake on the images were independently scored on a semiquantitative scale. RESULTS: 99mTc-PEG liposomes provided the earliest scintigraphic visualization of the abscess (as soon as 2 hours after the injection vs. 4 hours for the other two agents). Liposomes, IgG, and gallium all showed similarly high absolute uptake in the abscess. Focal uptake of liposomes and gallium correlated best with the extent of the macroscopic abnormalities. CONCLUSIONS: 99mTc-PEG liposomes and 99mTc-HYNIC IgG performed at least as well as the standard agent, 67Ga citrate, in the detection of experimental intraabdominal abscesses, with obvious advantages such as lower radiation exposure and more favorable physical properties. Of the two technetium agents, the liposomes seemed to be superior, providing the earliest diagnostic image and the best correlation with the inflammatory

  7. 14 CFR 1274.917 - Additional funds.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Additional funds. 1274.917 Section 1274.917... FIRMS Other Provisions and Special Conditions § 1274.917 Additional funds. Additional Funds July 2002... under the terms of this cooperative agreement. NASA is under no obligation to provide additional funds...

  8. 14 CFR 1274.917 - Additional funds.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Additional funds. 1274.917 Section 1274.917... FIRMS Other Provisions and Special Conditions § 1274.917 Additional funds. Additional Funds July 2002... under the terms of this cooperative agreement. NASA is under no obligation to provide additional funds...

  9. Reactor shutdown delays medical procedures

    NASA Astrophysics Data System (ADS)

    Gwynne, Peter

    2008-01-01

    A longer-than-expected maintenance shutdown of the Canadian nuclear reactor that produces North America's entire supply of molybdenum-99 - from which the radioactive isotopes technetium-99 and iodine-131 are made - caused delays to the diagnosis and treatment of thousands of seriously ill patients last month. Technetium-99 is a key component of nuclear-medicine scans, while iodine-131 is used to treat cancer and other diseases of the thyroid. Production eventually resumed, but only after the Canadian government had overruled the Canadian Nuclear Safety Commission (CNSC), which was still concerned about the reactor's safety.

  10. REPORT FOR COMMERCIAL GRADE NICKEL CHARACTERIZATION AND BENCHMARKING

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    None

    2012-12-20

    Oak Ridge Associated Universities (ORAU), under the Oak Ridge Institute for Science and Education (ORISE) contract, has completed the collection, sample analysis, and review of analytical results to benchmark the concentrations of gross alpha-emitting radionuclides, gross beta-emitting radionuclides, and technetium-99 in commercial grade nickel. This report presents methods, change management, observations, and statistical analysis of materials procured from sellers representing nine countries on four continents. The data suggest there is a low probability of detecting alpha- and beta-emitting radionuclides in commercial nickel. Technetium-99 was not detected in any samples, thus suggesting it is not present in commercial nickel.

  11. Amyloidosis of heart and liver: comparison of Tc-99m pyrophosphate and Tc-99m methylene diphosphonate for detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, V.W.; Caldarone, A.G.; Falk, R.H.

    1983-07-01

    A prospective, comparative study was made of the efficacy of technetium-99m pyrophosphate (Tc PYP) and technetium-99m methylene diphosphonate (Tc MDP) in detecting soft-tissue amyloidois. Tc PYP and Tc MDP scans were obtained within ten-day intervals in seven patients with histologically proven amyloidosis. Tc PYP was a better scanning agent for soft-tissue amyloidosis in all patients. Cardiac and hepatic involvement were proved by autopsy in one patient. Involvement of the heart was confirmed by echocardiography in five patients. The potential use of tc PYP scannning as a screening test for soft-tissue amyloidosis is discussed.

  12. Food additives: an ethical evaluation.

    PubMed

    Mepham, Ben

    2011-01-01

    Food additives are an integral part of the modern food system, but opinion polls showing most Europeans have worries about them imply an urgent need for ethical analysis of their use. The existing literature on food ethics, safety assessment and animal testing. Food additives provide certain advantages in terms of many people's lifestyles. There are disagreements about the appropriate application of the precautionary principle and of the value and ethical validity of animal tests in assessing human safety. Most consumers have a poor understanding of the relative benefits and risks of additives, but concerns over food safety and animal testing remain high. Examining the impacts of food additives on consumer sovereignty, consumer health and on animals used in safety testing should allow a more informed debate about their appropriate uses.

  13. Addition Table of Colours: Additive and Subtractive Mixtures Described Using a Single Reasoning Model

    ERIC Educational Resources Information Center

    Mota, A. R.; Lopes dos Santos, J. M. B.

    2014-01-01

    Students' misconceptions concerning colour phenomena and the apparent complexity of the underlying concepts--due to the different domains of knowledge involved--make its teaching very difficult. We have developed and tested a teaching device, the addition table of colours (ATC), that encompasses additive and subtractive mixtures in a single…

  14. Synthesis of Tc-99m labeled 1,2,3-triazole-4-yl c-met binding peptide as a potential c-met receptor kinase positive tumor imaging agent.

    PubMed

    Kim, Eun-Mi; Joung, Min-Hee; Lee, Chang-Moon; Jeong, Hwan-Jeong; Lim, Seok Tae; Sohn, Myung-Hee; Kim, Dong Wook

    2010-07-15

    The mesenchymal-epithelial transition factor (c-Met), which is related to tumor cell growth, angiogenesis and metastases, is known to be overexpressed in several tumor types. In this study, we synthesized technetium-99m labeled 1,2,3-triazole-4-yl c-Met binding peptide (cMBP) derivatives, prepared by solid phase peptide synthesis and the 'click-to-chelate' protocol for the introduction of tricarbonyl technetium-99m, as a potential c-Met receptor kinase positive tumor imaging agent, and evaluated their in vitro c-Met binding affinity, cellular uptake, and stability. The (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12, [(99m)Tc(CO)(3)]13, and [(99m)Tc(CO)(3)]14) were prepared in 85-90% radiochemical yields. The cold surrogate cMBP derivatives, [Re(CO)(3)]12, [Re(CO)(3)]13, and [Re(CO)(3)]14, were shown to have high binding affinities (0.13 microM, 0.06 microM, and 0.16 microM, respectively) to a purified cMet/Fc chimeric recombinant protein. In addition, the in vitro cellular uptake and inhibition studies demonstrated the high specific binding of these (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12-14) to c-Met receptor positive U87MG cells. 2010 Elsevier Ltd. All rights reserved.

  15. Food additives and preschool children.

    PubMed

    Martyn, Danika M; McNulty, Breige A; Nugent, Anne P; Gibney, Michael J

    2013-02-01

    Food additives have been used throughout history to perform specific functions in foods. A comprehensive framework of legislation is in place within Europe to control the use of additives in the food supply and ensure they pose no risk to human health. Further to this, exposure assessments are regularly carried out to monitor population intakes and verify that intakes are not above acceptable levels (acceptable daily intakes). Young children may have a higher dietary exposure to chemicals than adults due to a combination of rapid growth rates and distinct food intake patterns. For this reason, exposure assessments are particularly important in this age group. The paper will review the use of additives and exposure assessment methods and examine factors that affect dietary exposure by young children. One of the most widely investigated unfavourable health effects associated with food additive intake in preschool-aged children are suggested adverse behavioural effects. Research that has examined this relationship has reported a variety of responses, with many noting an increase in hyperactivity as reported by parents but not when assessed using objective examiners. This review has examined the experimental approaches used in such studies and suggests that efforts are needed to standardise objective methods of measuring behaviour in preschool children. Further to this, a more holistic approach to examining food additive intakes by preschool children is advisable, where overall exposure is considered rather than focusing solely on behavioural effects and possibly examining intakes of food additives other than food colours.

  16. Versatility of Cooperative Transcriptional Activation: A Thermodynamical Modeling Analysis for Greater-Than-Additive and Less-Than-Additive Effects

    PubMed Central

    Frank, Till D.; Carmody, Aimée M.; Kholodenko, Boris N.

    2012-01-01

    We derive a statistical model of transcriptional activation using equilibrium thermodynamics of chemical reactions. We examine to what extent this statistical model predicts synergy effects of cooperative activation of gene expression. We determine parameter domains in which greater-than-additive and less-than-additive effects are predicted for cooperative regulation by two activators. We show that the statistical approach can be used to identify different causes of synergistic greater-than-additive effects: nonlinearities of the thermostatistical transcriptional machinery and three-body interactions between RNA polymerase and two activators. In particular, our model-based analysis suggests that at low transcription factor concentrations cooperative activation cannot yield synergistic greater-than-additive effects, i.e., DNA transcription can only exhibit less-than-additive effects. Accordingly, transcriptional activity turns from synergistic greater-than-additive responses at relatively high transcription factor concentrations into less-than-additive responses at relatively low concentrations. In addition, two types of re-entrant phenomena are predicted. First, our analysis predicts that under particular circumstances transcriptional activity will feature a sequence of less-than-additive, greater-than-additive, and eventually less-than-additive effects when for fixed activator concentrations the regulatory impact of activators on the binding of RNA polymerase to the promoter increases from weak, to moderate, to strong. Second, for appropriate promoter conditions when activator concentrations are increased then the aforementioned re-entrant sequence of less-than-additive, greater-than-additive, and less-than-additive effects is predicted as well. Finally, our model-based analysis suggests that even for weak activators that individually induce only negligible increases in promoter activity, promoter activity can exhibit greater-than-additive responses when

  17. Color Addition and Subtraction Apps

    NASA Astrophysics Data System (ADS)

    Ruiz, Frances; Ruiz, Michael J.

    2015-10-01

    Color addition and subtraction apps in HTML5 have been developed for students as an online hands-on experience so that they can more easily master principles introduced through traditional classroom demonstrations. The evolution of the additive RGB color model is traced through the early IBM color adapters so that students can proceed step by step in understanding mathematical representations of RGB color. Finally, color addition and subtraction are presented for the X11 colors from web design to illustrate yet another real-life application of color mixing.

  18. 10 CFR 810.14 - Additional information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Additional information. 810.14 Section 810.14 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.14 Additional information. The... activity to submit additional information. ...

  19. Congruence of Additive and Non-Additive Effects on Gene Expression Estimated from Pedigree and SNP Data

    PubMed Central

    Powell, Joseph E.; Henders, Anjali K.; McRae, Allan F.; Kim, Jinhee; Hemani, Gibran; Martin, Nicholas G.; Dermitzakis, Emmanouil T.; Gibson, Greg

    2013-01-01

    There is increasing evidence that heritable variation in gene expression underlies genetic variation in susceptibility to disease. Therefore, a comprehensive understanding of the similarity between relatives for transcript variation is warranted—in particular, dissection of phenotypic variation into additive and non-additive genetic factors and shared environmental effects. We conducted a gene expression study in blood samples of 862 individuals from 312 nuclear families containing MZ or DZ twin pairs using both pedigree and genotype information. From a pedigree analysis we show that the vast majority of genetic variation across 17,994 probes is additive, although non-additive genetic variation is identified for 960 transcripts. For 180 of the 960 transcripts with non-additive genetic variation, we identify expression quantitative trait loci (eQTL) with dominance effects in a sample of 339 unrelated individuals and replicate 31% of these associations in an independent sample of 139 unrelated individuals. Over-dominance was detected and replicated for a trans association between rs12313805 and ETV6, located 4MB apart on chromosome 12. Surprisingly, only 17 probes exhibit significant levels of common environmental effects, suggesting that environmental and lifestyle factors common to a family do not affect expression variation for most transcripts, at least those measured in blood. Consistent with the genetic architecture of common diseases, gene expression is predominantly additive, but a minority of transcripts display non-additive effects. PMID:23696747

  20. Congruence of additive and non-additive effects on gene expression estimated from pedigree and SNP data.

    PubMed

    Powell, Joseph E; Henders, Anjali K; McRae, Allan F; Kim, Jinhee; Hemani, Gibran; Martin, Nicholas G; Dermitzakis, Emmanouil T; Gibson, Greg; Montgomery, Grant W; Visscher, Peter M

    2013-05-01

    There is increasing evidence that heritable variation in gene expression underlies genetic variation in susceptibility to disease. Therefore, a comprehensive understanding of the similarity between relatives for transcript variation is warranted--in particular, dissection of phenotypic variation into additive and non-additive genetic factors and shared environmental effects. We conducted a gene expression study in blood samples of 862 individuals from 312 nuclear families containing MZ or DZ twin pairs using both pedigree and genotype information. From a pedigree analysis we show that the vast majority of genetic variation across 17,994 probes is additive, although non-additive genetic variation is identified for 960 transcripts. For 180 of the 960 transcripts with non-additive genetic variation, we identify expression quantitative trait loci (eQTL) with dominance effects in a sample of 339 unrelated individuals and replicate 31% of these associations in an independent sample of 139 unrelated individuals. Over-dominance was detected and replicated for a trans association between rs12313805 and ETV6, located 4MB apart on chromosome 12. Surprisingly, only 17 probes exhibit significant levels of common environmental effects, suggesting that environmental and lifestyle factors common to a family do not affect expression variation for most transcripts, at least those measured in blood. Consistent with the genetic architecture of common diseases, gene expression is predominantly additive, but a minority of transcripts display non-additive effects.

  1. [Importance of parathyroid SPECT and 99mTc scintigraphy, and of clinical, laboratorial, ultrasonographic and citologic correlation in the pre-operative localization of the parathyroid adenoma - pictorial assay].

    PubMed

    Oliveira, Marco Antônio Condé de; Maeda, Sérgio Setsuo; Dreyer, Patrícia; Lobo, Alberto; Andrade, Victor Piana de; Hoff, Ana O; Biscolla, Rosa Paula Mello; Smanio, Paola; Brandão, Cynthia M A; Vieira, José G

    2010-06-01

    In patients with primary hyperparathyroidism, candidates for surgical intervention, the parathyroid pre-operative localization is of fundamental importance in planning the appropriate surgical approach. The additional acquisition of SPECT and Technetium-99m images, during parathyroid scintigraphy with Sestamibi, is not common practice. Usually, only planar image acquisition, 15 minutes prior and 2 hours after radiopharmaceutical administration, is performed. In our experience, the complete protocol in parathyroid scintigraphy increases the accuracy of pre-operative parathyroid localization. The complete utilization of all available nuclear medicine methods (SPECT e 99mTc) and image interpretation in a multidisciplinary context can improve the accuracy of parathyroid scintigraphy.

  2. Biobased lubricant additives

    USDA-ARS?s Scientific Manuscript database

    Fully biobased lubricants are those formulated using all biobased ingredients, i.e. biobased base oils and biobased additives. Such formulations provide the maximum environmental, safety, and economic benefits expected from a biobased product. Currently, there are a number of biobased base oils that...

  3. Behaviors of Polymer Additives Under EHL and Influences of Interactions Between Additives on Friction Modification

    NASA Technical Reports Server (NTRS)

    Sakurai, T.

    1984-01-01

    Polymer additives have become requisite for the formulation of multigrade engine oils. The behavior of polymethacrylate (PMA)-thickened oils as lubricants in concentrated contacts under nominal rolling and pure sliding conditions was investigated by conventional optical interferometry. The PMA thickened oils behaved differently from the base oil in the formation of elastohydrodynamic (EHL) films. The higher the elastohydrodynamic molecular weight of the PMA contained in the lubricant, the thinner was the oil film under EHL conditions. The film thickness of shear-degraded PMA-thickened oils was also investigated. The behavior of graphite particles dispersed in both the base oil and the PMA-thickened oil was studied under pure sliding by taking photomicrographs. Many kinds of additives are contained in lubricating oil and the interactions between additives are considered. The interactions of zinc-organodithiophosphates (ZDP) with other additives is discussed.

  4. Thiourea derivatives as chelating agents for bioconjugation of rhenium and technetium.

    PubMed

    Gomez, J D Castillo; Hagenbach, A; Gerling-Driessen, U I M; Koksch, B; Beindorff, N; Brenner, W; Abram, U

    2017-10-31

    Potential tetradentate thiocarbamoylbenzamidine derivatives H 4 L have been synthesized from the corresponding benzimidoyl chlorides and triglycine. They are suitable chelating agents for the oxidotechnetium(v) and oxidorhenium(v) cores and form stable, neutral [MO(HL)] complexes with an equatorial SN 3 coordination sphere and an additional, uncoordinated carboxylic group, which can be used for bioconjugation. Representatives of the rhenium and 99 Tc products have been isolated and analyzed with spectroscopic methods and X-ray diffraction. Bioconjugates of these complexes with angiotensin-II have been synthesized and structurally characterized. Analogous 99m Tc complexes have been produced and tested in vitro and in vivo. The experiments confirm a considerable stability for the [ 99m Tc(HL)] product as well as for its bioconjugate and recommend this class of compounds for further bioconjugation studies towards clinical applications.

  5. Direct comparison of solid-phase gastric emptying times assessed by means of a carbon isotope-labeled sodium acetate breath test and technetium Tc 99m albumin colloid radioscintigraphy in healthy cats.

    PubMed

    Schmitz, Silke; Götte, Birte; Borsch, Christian; Kunz, Clemens; Failing, Klaus; Neiger, Reto

    2014-07-01

    To directly compare solid-phase gastric emptying times assessed by means of a [(13)C]sodium acetate breath test ([(13)C]-SABT) and technetium Tc 99m albumin colloid radioscintigraphy ((99m)Tc-ACR) in healthy cats. 12 healthy cats. After ingestion of a test meal containing 50 mg of [(13)C]sodium acetate and 250 MBq of (99m)Tc-albumin colloid, each cat underwent simultaneous [(13)C]-SABT and (99m)Tc-ACR on 2 consecutive days. Breath samples and scintigrams were acquired at 30, 60, 90, 120, 150, 180, 210, 240, 300, 360, 480, and 600 minutes after meal ingestion. Quartiles of gastric emptying (25%, 50%, and 75%) were calculated for breath test analysis by use of the area under the curve of the (13)C:(12)C ratio. Quartiles of gastric emptying times were extrapolated from the scintigraphic findings by beans of nonlinear curve regression analysis. Mean ± SD gastric half-emptying (50%) times obtained with [(13)C]-SABT and (99m)Tc-ACR, were 239 ± 28 minutes and 276 ± 59 minutes, respectively. A 2-way repeated-measures ANOVA revealed that mean gastric emptying times determined with [(13)C]-SABT and (99m)Tc-ACR differed significantly. For the stages of gastric emptying, Pearson correlation between the 2 methods was good at 25% (r = 0.655) and weak at 50% (r = 0.588) and 75% (r = 0.566)of gastric emptying. Results indicated that the [(13)C]-SABT can be a valid alternative to (99m)Tc-ACR in healthy cats; it was easy to perform, was tolerated well by the cats, and had acceptable correlation to scintigraphic findings at gastric emptying of 25%, 50% and 75%. Studies in cats with delayed gastric emptying will be needed to verify the validity of the [(13)C]-SABT.

  6. Additive manufacturing: Toward holistic design

    DOE PAGES

    Jared, Bradley H.; Aguilo, Miguel A.; Beghini, Lauren L.; ...

    2017-03-18

    Here, additive manufacturing offers unprecedented opportunities to design complex structures optimized for performance envelopes inaccessible under conventional manufacturing constraints. Additive processes also promote realization of engineered materials with microstructures and properties that are impossible via traditional synthesis techniques. Enthused by these capabilities, optimization design tools have experienced a recent revival. The current capabilities of additive processes and optimization tools are summarized briefly, while an emerging opportunity is discussed to achieve a holistic design paradigm whereby computational tools are integrated with stochastic process and material awareness to enable the concurrent optimization of design topologies, material constructs and fabrication processes.

  7. 10 CFR 20.2302 - Additional requirements.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 1 2012-01-01 2012-01-01 false Additional requirements. 20.2302 Section 20.2302 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Exemptions and Additional Requirements § 20.2302 Additional requirements. The Commission may, by rule, regulation, or order, impose...

  8. 10 CFR 20.2302 - Additional requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 1 2014-01-01 2014-01-01 false Additional requirements. 20.2302 Section 20.2302 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Exemptions and Additional Requirements § 20.2302 Additional requirements. The Commission may, by rule, regulation, or order, impose...

  9. 10 CFR 20.2302 - Additional requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 1 2010-01-01 2010-01-01 false Additional requirements. 20.2302 Section 20.2302 Energy NUCLEAR REGULATORY COMMISSION STANDARDS FOR PROTECTION AGAINST RADIATION Exemptions and Additional Requirements § 20.2302 Additional requirements. The Commission may, by rule, regulation, or order, impose...

  10. Evaluation of certain food additives.

    PubMed

    2015-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives, including flavouring agents, and to prepare specifications for identity and purity. The first part of the report contains a general discussion of the principles governing the toxicological evaluation of and assessment of dietary exposure to food additives, including flavouring agents. A summary follows of the Committee's evaluations of technical, toxicological and dietary exposure data for eight food additives (Benzoe tonkinensis; carrageenan; citric and fatty acid esters of glycerol; gardenia yellow; lutein esters from Tagetes erecta; octenyl succinic acid-modified gum arabic; octenyl succinic acid-modified starch; paprika extract; and pectin) and eight groups of flavouring agents (aliphatic and alicyclic hydrocarbons; aliphatic and aromatic ethers; ionones and structurally related substances; miscellaneous nitrogen-containing substances; monocyclic and bicyclic secondary alcohols, ketones and related esters; phenol and phenol derivatives; phenyl-substituted aliphatic alcohols and related aldehydes and esters; and sulfur-containing heterocyclic compounds). Specifications for the following food additives were revised: citric acid; gellan gum; polyoxyethylene (20) sorbitan monostearate; potassium aluminium silicate; and Quillaia extract (Type 2). Annexed to the report are tables summarizing the Committee's recommendations for dietary exposures to and toxicological evaluations of all of the food additives and flavouring agents considered at this meeting.

  11. 47 CFR 25.111 - Additional information.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 47 Telecommunication 2 2013-10-01 2013-10-01 false Additional information. 25.111 Section 25.111... Applications and Licenses General Application Filing Requirements § 25.111 Additional information. (a) The Commission may request from any party at any time additional information concerning any application, or any...

  12. 47 CFR 25.111 - Additional information.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 47 Telecommunication 2 2012-10-01 2012-10-01 false Additional information. 25.111 Section 25.111... Applications and Licenses General Application Filing Requirements § 25.111 Additional information. (a) The Commission may request from any party at any time additional information concerning any application, or any...

  13. 47 CFR 25.111 - Additional information.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 47 Telecommunication 2 2011-10-01 2011-10-01 false Additional information. 25.111 Section 25.111... Applications and Licenses General Application Filing Requirements § 25.111 Additional information. (a) The Commission may request from any party at any time additional information concerning any application, or any...

  14. 17 CFR 230.408 - Additional information.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 17 Commodity and Securities Exchanges 2 2013-04-01 2013-04-01 false Additional information. 230... RULES AND REGULATIONS, SECURITIES ACT OF 1933 General Requirements § 230.408 Additional information. (a) In addition to the information expressly required to be included in a registration statement, there...

  15. 14 CFR 27.927 - Additional tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Additional tests. 27.927 Section 27.927... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  16. 14 CFR 27.927 - Additional tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Additional tests. 27.927 Section 27.927... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  17. 14 CFR 29.927 - Additional tests.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Additional tests. 29.927 Section 29.927... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  18. 14 CFR 27.927 - Additional tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Additional tests. 27.927 Section 27.927... STANDARDS: NORMAL CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 27.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  19. 14 CFR 29.927 - Additional tests.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Additional tests. 29.927 Section 29.927... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  20. 14 CFR 29.927 - Additional tests.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Additional tests. 29.927 Section 29.927... STANDARDS: TRANSPORT CATEGORY ROTORCRAFT Powerplant Rotor Drive System § 29.927 Additional tests. (a) Any additional dynamic, endurance, and operational tests, and vibratory investigations necessary to determine...

  1. 5 CFR 1315.11 - Additional penalties.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Additional penalties. 1315.11 Section 1315.11 Administrative Personnel OFFICE OF MANAGEMENT AND BUDGET OMB DIRECTIVES PROMPT PAYMENT § 1315.11 Additional penalties. (a) Vendor entitlements. A vendor shall be entitled to an additional penalty...

  2. 10 CFR 55.7 - Additional requirements.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 2 2014-01-01 2014-01-01 false Additional requirements. 55.7 Section 55.7 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) OPERATORS' LICENSES General Provisions § 55.7 Additional requirements. The Commission may, by rule, regulation, or order, impose upon any licensee such requirements, in addition to...

  3. 42 CFR 412.115 - Additional payments.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... PROSPECTIVE PAYMENT SYSTEMS FOR INPATIENT HOSPITAL SERVICES Payments to Hospitals Under the Prospective Payment Systems § 412.115 Additional payments. (a) Bad debts. An additional payment is made to each... 42 Public Health 2 2010-10-01 2010-10-01 false Additional payments. 412.115 Section 412.115 Public...

  4. 10 CFR 55.7 - Additional requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Additional requirements. 55.7 Section 55.7 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) OPERATORS' LICENSES General Provisions § 55.7 Additional requirements. The Commission may, by rule, regulation, or order, impose upon any licensee such requirements, in addition to...

  5. Estimating Additive and Non-Additive Genetic Variances and Predicting Genetic Merits Using Genome-Wide Dense Single Nucleotide Polymorphism Markers

    PubMed Central

    Su, Guosheng; Christensen, Ole F.; Ostersen, Tage; Henryon, Mark; Lund, Mogens S.

    2012-01-01

    Non-additive genetic variation is usually ignored when genome-wide markers are used to study the genetic architecture and genomic prediction of complex traits in human, wild life, model organisms or farm animals. However, non-additive genetic effects may have an important contribution to total genetic variation of complex traits. This study presented a genomic BLUP model including additive and non-additive genetic effects, in which additive and non-additive genetic relation matrices were constructed from information of genome-wide dense single nucleotide polymorphism (SNP) markers. In addition, this study for the first time proposed a method to construct dominance relationship matrix using SNP markers and demonstrated it in detail. The proposed model was implemented to investigate the amounts of additive genetic, dominance and epistatic variations, and assessed the accuracy and unbiasedness of genomic predictions for daily gain in pigs. In the analysis of daily gain, four linear models were used: 1) a simple additive genetic model (MA), 2) a model including both additive and additive by additive epistatic genetic effects (MAE), 3) a model including both additive and dominance genetic effects (MAD), and 4) a full model including all three genetic components (MAED). Estimates of narrow-sense heritability were 0.397, 0.373, 0.379 and 0.357 for models MA, MAE, MAD and MAED, respectively. Estimated dominance variance and additive by additive epistatic variance accounted for 5.6% and 9.5% of the total phenotypic variance, respectively. Based on model MAED, the estimate of broad-sense heritability was 0.506. Reliabilities of genomic predicted breeding values for the animals without performance records were 28.5%, 28.8%, 29.2% and 29.5% for models MA, MAE, MAD and MAED, respectively. In addition, models including non-additive genetic effects improved unbiasedness of genomic predictions. PMID:23028912

  6. Adsorption of molecular additive onto lead halide perovskite surfaces: A computational study on Lewis base thiophene additive passivation

    NASA Astrophysics Data System (ADS)

    Zhang, Lei; Yu, Fengxi; Chen, Lihong; Li, Jingfa

    2018-06-01

    Organic additives, such as the Lewis base thiophene, have been successfully applied to passivate halide perovskite surfaces, improving the stability and properties of perovskite devices based on CH3NH3PbI3. Yet, the detailed nanostructure of the perovskite surface passivated by additives and the mechanisms of such passivation are not well understood. This study presents a nanoscopic view on the interfacial structure of an additive/perovskite interface, consisting of a Lewis base thiophene molecular additive and a lead halide perovskite surface substrate, providing insights on the mechanisms that molecular additives can passivate the halide perovskite surfaces and enhance the perovskite-based device performance. Molecular dynamics study on the interactions between water molecules and the perovskite surfaces passivated by the investigated additive reveal the effectiveness of employing the molecular additives to improve the stability of the halide perovskite materials. The additive/perovskite surface system is further probed via molecular engineering the perovskite surfaces. This study reveals the nanoscopic structure-property relationships of the halide perovskite surface passivated by molecular additives, which helps the fundamental understanding of the surface/interface engineering strategies for the development of halide perovskite based devices.

  7. 10 CFR 725.13 - Additional information.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Additional information. 725.13 Section 725.13 Energy DEPARTMENT OF ENERGY PERMITS FOR ACCESS TO RESTRICTED DATA Applications § 725.13 Additional information. The... and before the termination of the permit, require additional information in order to enable the Chief...

  8. 28 CFR 80.7 - Additional information.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 28 Judicial Administration 2 2013-07-01 2013-07-01 false Additional information. 80.7 Section 80.7... § 80.7 Additional information. If an issuer's or domestic concern's submission does not contain all of the information required by § 80.6, the Department of Justice may request whatever additional...

  9. 46 CFR 355.5 - Additional material.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 8 2011-10-01 2011-10-01 false Additional material. 355.5 Section 355.5 Shipping... STATES CITIZENSHIP § 355.5 Additional material. If additional material is determined to be essential to clarify or support the evidence of U.S. citizenship, such material shall be furnished by the...

  10. 46 CFR 355.5 - Additional material.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 8 2014-10-01 2014-10-01 false Additional material. 355.5 Section 355.5 Shipping... STATES CITIZENSHIP § 355.5 Additional material. If additional material is determined to be essential to clarify or support the evidence of U.S. citizenship, such material shall be furnished by the...

  11. 46 CFR 355.5 - Additional material.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 8 2013-10-01 2013-10-01 false Additional material. 355.5 Section 355.5 Shipping... STATES CITIZENSHIP § 355.5 Additional material. If additional material is determined to be essential to clarify or support the evidence of U.S. citizenship, such material shall be furnished by the...

  12. 18 CFR 33.10 - Additional information.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... § 33.10 Additional information. The Director of the Office of Energy Market Regulation, or his designee, may, by letter, require the applicant to submit additional information as is needed for analysis of an... 18 Conservation of Power and Water Resources 1 2013-04-01 2013-04-01 false Additional information...

  13. 18 CFR 33.10 - Additional information.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... § 33.10 Additional information. The Director of the Office of Energy Market Regulation, or his designee, may, by letter, require the applicant to submit additional information as is needed for analysis of an... 18 Conservation of Power and Water Resources 1 2011-04-01 2011-04-01 false Additional information...

  14. 18 CFR 33.10 - Additional information.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... § 33.10 Additional information. The Director of the Office of Energy Market Regulation, or his designee, may, by letter, require the applicant to submit additional information as is needed for analysis of an... 18 Conservation of Power and Water Resources 1 2014-04-01 2014-04-01 false Additional information...

  15. Creatine kinase MB isoenzyme in dermatomyositis: a noncardiac source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larca, L.J.; Coppola, J.T.; Honig, S.

    1981-03-01

    Three patients with polymyositis had elevated serum levels of creatine kinase MB isoenzyme. The presence of this isoenzyme is used extensively to diagnose myocardial infarction, but the isoenzyme is also found in sera of patients with primary muscular and neuromuscular disorders. Researchers studied cardiac function in two of our patients with electrocardiograms, technetium stannous pyrophosphate scanning, and technetium 99m-labeled erythrocyte gated blood pool imaging and in the third patient by postmortem examination. There was no evidence of myocardial involvement to account for the high serum levels of isoenzyme. Creatine kinase MB in the sera of patients with polymyositis does notmore » necessarily indicate myocardial necrosis.« less

  16. Active mineral additives of sapropel ashes

    NASA Astrophysics Data System (ADS)

    Khomich, V. A.; Danilina, E. V.; Krivonos, O. I.; Plaksin, G. V.

    2015-01-01

    The goal of the presented research is to establish a scientific rational for the possibility of sapropel ashes usage as an active mineral additive. The research included the study of producing active mineral additives from sapropels by their thermal treatment at 850900 °C and afterpowdering, the investigation of the properties of paste matrix with an ash additive, and the study of the ash influence on the cement bonding agent. Thermogravimetric analysis and X-ray investigations allowed us to establish that while burning, organic substances are removed, clay minerals are dehydrated and their structure is broken. Sapropel ashes chemical composition was determined. An amorphous ash constituent is mainly formed from silica of the mineral sapropel part and alumosilicagels resulted from clay minerals decomposition. Properties of PC 400 and PC 500A0 sparopel ash additives were studied. Adding ashes containing Glenium plasticizer to the cement increases paste matrix strength and considerably reduces its water absorption. X-ray phase analysis data shows changes in the phase composition of the paste matrix with an ash additive. Ash additives produce a pozzolanic effect on the cement bonding agent. Besides, an ash additive due to the alumosilicagels content causes transformation from unstable calcium aluminate forms to the stable ones.

  17. 34 CFR 75.231 - Additional information.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 34 Education 1 2014-07-01 2014-07-01 false Additional information. 75.231 Section 75.231 Education... Make A Grant § 75.231 Additional information. After selecting an application for funding, the Secretary may require the applicant to submit additional information. (Authority: 20 U.S.C. 1221e-3 and 3474) ...

  18. Evaluation of certain food additives.

    PubMed

    2017-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives, including flavouring agents, with a view to concluding as to safety concerns and to preparing specifications for identity and purity. The first part of the report contains a general discussion of the principles governing the toxicological evaluation of and assessment of dietary exposure to food additives, including flavouring agents. A summary follows of the Committee’s evaluations of technical, toxicological and dietary exposure data for 10 food additives (Allura Red AC; carob bean gum; lutein esters from Tagetes erecta; octenyl succinic acid (OSA)– modified gum arabic; pectin; Quinoline Yellow; rosemary extract; steviol glycosides; tartrazine; and xanthan gum) and five groups of flavouring agents (alicyclic, alicyclic-fused and aromatic-fused ring lactones; aliphatic and aromatic amines and amides; aliphatic secondary alcohols, ketones and related esters; cinnamyl alcohol and related substances; and tetrahydrofuran and furanone derivatives). Specifications for the following food additives were revised: aspartame; cassia gum; citric and fatty acid esters of glycerol (CITREM); modified starches; octanoic acid; starch sodium octenyl succinate; and total colouring matters. Annexed to the report are tables summarizing the Committee’s recommendations for dietary exposures to and toxicological evaluations of all of the food additives, including flavouring agents, considered at this meeting.

  19. The dilemma of allergy to food additives.

    PubMed

    Bahna, Sami L; Burkhardt, Joshua G

    2018-01-01

    To provide a brief summary on food additives and to outline a practical approach for evaluating subjects suspected of having reactions to food additives. Information was derived from selected reviews and original articles published in peer-reviewed journals, supplemented by the clinical experience of the authors. Priority was given to studies that used blinded, placebo controlled, oral challenges to confirm adverse reactions to food additives. In addition, selected, appropriately evaluated case reports were included. A large number of food additives are widely used in the food industry. Allergic reactions to additives seem to be rare but are very likely underdiagnosed, primarily due to a low index of suspicion. A wide variety of symptoms to food additives have been reported, but a cause-and-effect relationship has not been well documented in the majority of cases. Reactions to food additives should be suspected in patients who report symptoms related to multiple foods or to a certain food when commercially prepared but not when home made. It is also prudent to investigate food additives in subjects considered to have "idiopathic" reactions. Except for a limited number of natural additives, there is a small role for skin tests or in vitro testing. Oral challenge, in stages, with commonly used additives is the definitive procedure for detecting the offending agent. Once the specific additive is identified, management is strict avoidance, which can be difficult.

  20. 7 CFR 47.47 - Additional definitions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Additional definitions. 47.47 Section 47.47... Commodities Act § 47.47 Additional definitions. The following definitions, which are in addition to those in § 47.2 (a) through (h), shall be applicable to proceedings under §§ 47.47 through 47.49. (a) Chief...

  1. Septic tank additive impacts on microbial populations.

    PubMed

    Pradhan, S; Hoover, M T; Clark, G H; Gumpertz, M; Wollum, A G; Cobb, C; Strock, J

    2008-01-01

    Environmental health specialists, other onsite wastewater professionals, scientists, and homeowners have questioned the effectiveness of septic tank additives. This paper describes an independent, third-party, field scale, research study of the effects of three liquid bacterial septic tank additives and a control (no additive) on septic tank microbial populations. Microbial populations were measured quarterly in a field study for 12 months in 48 full-size, functioning septic tanks. Bacterial populations in the 48 septic tanks were statistically analyzed with a mixed linear model. Additive effects were assessed for three septic tank maintenance levels (low, intermediate, and high). Dunnett's t-test for tank bacteria (alpha = .05) indicated that none of the treatments were significantly different, overall, from the control at the statistical level tested. In addition, the additives had no significant effects on septic tank bacterial populations at any of the septic tank maintenance levels. Additional controlled, field-based research iswarranted, however, to address additional additives and experimental conditions.

  2. Polymeric Additives For Graphite/Epoxy Composites

    NASA Technical Reports Server (NTRS)

    Kourtides, D. A.; Nir, Z.

    1990-01-01

    Report describes experimental studies of properties of several graphite/epoxy composites containing polymeric additives as flexibilizing or toughening agents. Emphasizes effects of brominated polymeric additives (BPA's) with or without carboxy-terminated butadiene acrylonitrile rubber. Reviews effects of individual and combined additives on fracture toughnesses, environmental stabilities, hot/wet strengths, thermomechanical behaviors, and other mechanical properties of composites.

  3. Additivity vs Synergism: Investigation of the Additive Interaction of Cinnamon Bark Oil and Meropenem in Combinatory Therapy.

    PubMed

    Yang, Shun-Kai; Yusoff, Khatijah; Mai, Chun-Wai; Lim, Wei-Meng; Yap, Wai-Sum; Lim, Swee-Hua Erin; Lai, Kok-Song

    2017-11-04

    Combinatory therapies have been commonly applied in the clinical setting to tackle multi-drug resistant bacterial infections and these have frequently proven to be effective. Specifically, combinatory therapies resulting in synergistic interactions between antibiotics and adjuvant have been the main focus due to their effectiveness, sidelining the effects of additivity, which also lowers the minimal effective dosage of either antimicrobial agent. Thus, this study was undertaken to look at the effects of additivity between essential oils and antibiotic, via the use of cinnamon bark essential oil (CBO) and meropenem as a model for additivity. Comparisons between synergistic and additive interaction of CBO were performed in terms of the ability of CBO to disrupt bacterial membrane, via zeta potential measurement, outer membrane permeability assay and scanning electron microscopy. It has been found that the additivity interaction between CBO and meropenem showed similar membrane disruption ability when compared to those synergistic combinations which was previously reported. Hence, results based on our studies strongly suggest that additive interaction acts on a par with synergistic interaction. Therefore, further investigation in additive interaction between antibiotics and adjuvant should be performed for a more in depth understanding of the mechanism and the impacts of such interaction.

  4. Fire-Retardant Polymeric Additives

    NASA Technical Reports Server (NTRS)

    Williams, Martha K.; Smith, Trent M.

    2011-01-01

    Polyhydroxyamide (PHA) and polymethoxyamide (PMeOA) are fire-retardant (FR) thermoplastic polymers and have been found to be useful as an additive for imparting fire retardant properties to other compatible, thermoplastic polymers (including some elastomers). Examples of compatible flammable polymers include nylons, polyesters, and acrylics. Unlike most prior additives, PHA and PMeOA do not appreciably degrade the mechanical properties of the matrix polymer; indeed, in some cases, mechanical properties are enhanced. Also, unlike some prior additives, PHA and PMeOA do not decompose into large amounts of corrosive or toxic compounds during combustion and can be processed at elevated temperatures. PMeOA derivative formulations were synthesized and used as an FR additive in the fabrication of polyamide (PA) and polystyrene (PS) composites with notable reduction (>30 percent for PS) in peak heat release rates compared to the neat polymer as measured by a Cone Calorimeter (ASTM E1354). Synergistic effects were noted with nanosilica composites. These nanosilica composites had more than 50-percent reduction in peak heat release rates. In a typical application, a flammable thermoplastic, thermoplastic blend, or elastomer that one seeks to render flame-retardant is first dry-mixed with PHA or PMeOA or derivative thereof. The proportion of PHA or PMeOA or derivative in the mixture is typically chosen to lie between 1 and 20 weight percent. The dry blend can then be melt-extruded. The extruded polymer blend can further be extruded and/or molded into fibers, pipes, or any other of a variety of objects that may be required to be fire-retardant. The physical and chemical mechanisms which impart flame retardancy of the additive include inhibiting free-radical oxidation in the vapor phase, preventing vaporization of fuel (the polymer), and cooling through the formation of chemical bonds in either the vapor or the condensed phase. Under thermal stress, the cyclic hydroxyl/ methoxy

  5. Color Addition and Subtraction Apps

    ERIC Educational Resources Information Center

    Ruiz, Frances; Ruiz, Michael J.

    2015-01-01

    Color addition and subtraction apps in HTML5 have been developed for students as an online hands-on experience so that they can more easily master principles introduced through traditional classroom demonstrations. The evolution of the additive RGB color model is traced through the early IBM color adapters so that students can proceed step by step…

  6. Additive manufacturing of tunable lenses

    NASA Astrophysics Data System (ADS)

    Schlichting, Katja; Novak, Tobias; Heinrich, Andreas

    2017-02-01

    Individual additive manufacturing of optical systems based on 3D Printing offers varied possibilities in design and usage. In addition to the additive manufacturing procedure, the usage of tunable lenses allows further advantages for intelligent optical systems. Our goal is to bring the advantages of additive manufacturing together with the huge potential of tunable lenses. We produced tunable lenses as a bundle without any further processing steps, like polishing. The lenses were designed and directly printed with a 3D Printer as a package. The design contains the membrane as an optical part as well as the mechanical parts of the lens, like the attachments for the sleeves which contain the oil. The dynamic optical lenses were filled with an oil. The focal length of the lenses changes due to a change of the radius of curvature. This change is caused by changing the pressure in the inside of the lens. In addition to that, we designed lenses with special structures to obtain different areas with an individual optical power. We want to discuss the huge potential of this technology for several applications. Further, an appropriate controlling system is needed. Wéll show the possibilities to control and regulate the optical power of the lenses. The lenses could be used for illumination tasks, and in the future, for individual measurement tasks. The main advantage is the individuality and the possibility to create an individual design which completely fulfills the requirements for any specific application.

  7. 42 CFR 417.592 - Additional benefits requirement.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 3 2012-10-01 2012-10-01 false Additional benefits requirement. 417.592 Section... PLANS, AND HEALTH CARE PREPAYMENT PLANS Medicare Payment: Risk Basis § 417.592 Additional benefits...) Additional benefits. Provide its Medicare enrollees with additional benefits in accordance with paragraph (c...

  8. Cast Stone Oxidation Front Evaluation: Preliminary Results For Samples Exposed To Moist Air

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langton, C. A.; Almond, P. M.

    The rate of oxidation is important to the long-term performance of reducing salt waste forms because the solubility of some contaminants, e.g., technetium, is a function of oxidation state. TcO{sub 4}{sup -} in the salt solution is reduced to Tc(IV) and has been shown to react with ingredients in the waste form to precipitate low solubility sulfide and/or oxide phases. Upon exposure to oxygen, the compounds containing Tc(IV) oxidize to the pertechnetate ion, Tc(VII)O{sub 4}{sup -}, which is very soluble. Consequently the rate of technetium oxidation front advancement into a monolith and the technetium leaching profile as a function ofmore » depth from an exposed surface are important to waste form performance and ground water concentration predictions. An approach for measuring contaminant oxidation rate (effective contaminant specific oxidation rate) based on leaching of select contaminants of concern is described in this report. In addition, the relationship between reduction capacity and contaminant oxidation is addressed. Chromate (Cr(VI) was used as a non-radioactive surrogate for pertechnetate, Tc(VII), in Cast Stone samples prepared with 5 M Simulant. Cast Stone spiked with pertechnetate was also prepared and tested. Depth discrete subsamples spiked with Cr were cut from Cast Stone exposed to Savannah River Site (SRS) outdoor ambient temperature fluctuations and moist air. Depth discrete subsamples spiked with Tc-99 were cut from Cast Stone exposed to laboratory ambient temperature fluctuations and moist air. Similar conditions are expected to be encountered in the Cast Stone curing container. The leachability of Cr and Tc-99 and the reduction capacities, measured by the Angus-Glasser method, were determined for each subsample as a function of depth from the exposed surface. The results obtained to date were focused on continued method development and are preliminary and apply to the sample composition and curing / exposure conditions described in this

  9. From Addition to Multiplication ... and Back: The Development of Students' Additive and Multiplicative Reasoning Skills

    ERIC Educational Resources Information Center

    Van Dooren, Wim; De Bock, Dirk; Verschaffel, Lieven

    2010-01-01

    This study builds on two lines of research that have so far developed largely separately: the use of additive methods to solve proportional word problems and the use of proportional methods to solve additive word problems. We investigated the development with age of both kinds of erroneous solution methods. We gave a test containing missing-value…

  10. Terminal addition in a cellular world.

    PubMed

    Torday, J S; Miller, William B

    2018-07-01

    Recent advances in our understanding of evolutionary development permit a reframed appraisal of Terminal Addition as a continuous historical process of cellular-environmental complementarity. Within this frame of reference, evolutionary terminal additions can be identified as environmental induction of episodic adjustments to cell-cell signaling patterns that yield the cellular-molecular pathways that lead to differing developmental forms. Phenotypes derive, thereby, through cellular mutualistic/competitive niche constructions in reciprocating responsiveness to environmental stresses and epigenetic impacts. In such terms, Terminal Addition flows according to a logic of cellular needs confronting environmental challenges over space-time. A reconciliation of evolutionary development and Terminal Addition can be achieved through a combined focus on cell-cell signaling, molecular phylogenies and a broader understanding of epigenetic phenomena among eukaryotic organisms. When understood in this manner, Terminal Addition has an important role in evolutionary development, and chronic disease might be considered as a form of 'reverse evolution' of the self-same processes. Copyright © 2017. Published by Elsevier Ltd.

  11. Images of liposarcoma using technetium-99m bleomycin and technetium (V)-99m DMSA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, H.; Shane, F.I.; Endo, K.

    1986-12-01

    The effectiveness of Tc-99m bleomycin (BLM) and Tc(V)-99m DMSA are compared with that of Ga-67 citrate, which is currently the most widely used agent. In four patients with lipomatous tumors, the clinical significance of tumor imaging with each of these three agents is discussed and compared. Results indicate that both Tc-99m BLM and Tc(V)-99m DMSA are superior in detecting the extension or localization of liposarcomas.

  12. Nanocrystal Additives for Advanced Lubricants

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cooper, Gregory; Lohuis, James; Demas, Nicholaos

    The innovations in engine and drivetrain lubricants are mainly driven by ever more stringent regulations, which demand better fuel economy, lower carbon emission, and less pollution. Many technologies are being developed for the next generations of vehicles to achieve these goals. Even if these technologies can be adopted, there still is a significant need for a “drop-in” lubricant solution for the existing ground vehicle fleet to reap immediate fuel savings at the same time reduce the pollution. Dramatic improvements were observed when Pixelligent’s proprietary, mono-dispersed, and highly scalable metal oxide nanocrystals were added to the base oils. The dispersions inmore » base and formulated oils are clear and without any change of appearance and viscosity. However, the benefits provided by the nanocrystals were limited to the base oils due to the interference of exiting additives in the fully formulated oils. Developing a prototype formulation including the nanocrystals that can demonstrate the same improvements observed in the base oils is a critical step toward the commercialization of these advanced nano-additives. A ‘bottom-up’ approach was adopted to develop a prototype lubricant formulation to avoid the complicated interactions with the multitude of additives, only minimal numbers of most essential additives are added, step by step, into the formulation, to ensure that they are compatible with the nanocrystals and do not compromise their tribological performance. Tribological performance are characterized to come up with the best formulations that can demonstrate the commercial potential of the nano-additives.« less

  13. Tackifier for addition polyimides

    NASA Technical Reports Server (NTRS)

    Butler, J. M.; St.clair, T. L.

    1980-01-01

    A modification to the addition polyimide, LaRC-160, was prepared to improve tack and drape and increase prepeg out-time. The essentially solventless, high viscosity laminating resin is synthesized from low cost liquid monomers. The modified version takes advantage of a reactive, liquid plasticizer which is used in place of solvent and helps solve a major problem of maintaining good prepeg tack and drape, or the ability of the prepeg to adhere to adjacent plies and conform to a desired shape during the lay up process. This alternate solventless approach allows both longer life of the polymer prepeg and the processing of low void laminates. This approach appears to be applicable to all addition polyimide systems.

  14. 21 CFR 173.310 - Boiler water additives.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Boiler water additives. 173.310 Section 173.310... CONSUMPTION Specific Usage Additives § 173.310 Boiler water additives. Boiler water additives may be safely... water. Copolymer contains not more than 0.5 percent by weight of acrylic acid monomer (dry weight basis...

  15. 21 CFR 173.310 - Boiler water additives.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Boiler water additives. 173.310 Section 173.310... CONSUMPTION Specific Usage Additives § 173.310 Boiler water additives. Boiler water additives may be safely... water. Copolymer contains not more than 0.5 percent by weight of acrylic acid monomer (dry weight basis...

  16. 21 CFR 173.310 - Boiler water additives.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Boiler water additives. 173.310 Section 173.310... CONSUMPTION Specific Usage Additives § 173.310 Boiler water additives. Boiler water additives may be safely... water. Copolymer contains not more than 0.5 percent by weight of acrylic acid monomer (dry weight basis...

  17. 16 CFR 1102.16 - Additional information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... PUBLICLY AVAILABLE CONSUMER PRODUCT SAFETY INFORMATION DATABASE Content Requirements § 1102.16 Additional... in the Database any additional information it determines to be in the public interest, consistent...

  18. 16 CFR 1102.16 - Additional information.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... PUBLICLY AVAILABLE CONSUMER PRODUCT SAFETY INFORMATION DATABASE Content Requirements § 1102.16 Additional... in the Database any additional information it determines to be in the public interest, consistent...

  19. Lubricant additive concentrate containing isomerized jojoba oil

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Arndt, G.

    1987-05-12

    This patent describes a crankcase motor oil additive concentrate intended to be added to a conventional crankcase motor oil to improve its ability to lubricate and protect the engine. The additive concentrate comprises the following components: A petroleum base stock of lubricating quality and viscosity. The base stock comprises from about 13.5 to 90 weight percent of the additive concentrate; a detergent-inhibitor package. The package is present at from about 7 to about 40 weight percent of the concentrate; a supplemental antiwear additive selected from the salts of dialkyl dithiophosporic acids. The additive is present at a level of frommore » about 1 to about 10 weight percent of the concentrate; and a supplemental antiwear additive selected from the class of sulfurized olefins. The additive is present at a level of from about 1 to about 10 weight percent of the concentrate.« less

  20. Cincinnati Big Area Additive Manufacturing (BAAM)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Duty, Chad E.; Love, Lonnie J.

    Oak Ridge National Laboratory (ORNL) worked with Cincinnati Incorporated (CI) to demonstrate Big Area Additive Manufacturing which increases the speed of the additive manufacturing (AM) process by over 1000X, increases the size of parts by over 10X and shows a cost reduction of over 100X. ORNL worked with CI to transition the Big Area Additive Manufacturing (BAAM) technology from a proof-of-principle (TRL 2-3) demonstration to a prototype product stage (TRL 7-8).

  1. Food Additives Permitted for Direct Addition to Food for Human Consumption; Folic Acid. Final rule.

    PubMed

    2016-04-15

    The Food and Drug Administration (FDA or we) is amending the food additive regulations to provide for the safe use of folic acid in corn masa flour. We are taking this action in response to a food additive petition filed jointly by Gruma Corporation, Spina Bifida Association, March of Dimes Foundation, American Academy of Pediatrics, Royal DSM N.V., and National Council of La Raza.

  2. Non-additive Effects in Genomic Selection

    PubMed Central

    Varona, Luis; Legarra, Andres; Toro, Miguel A.; Vitezica, Zulma G.

    2018-01-01

    In the last decade, genomic selection has become a standard in the genetic evaluation of livestock populations. However, most procedures for the implementation of genomic selection only consider the additive effects associated with SNP (Single Nucleotide Polymorphism) markers used to calculate the prediction of the breeding values of candidates for selection. Nevertheless, the availability of estimates of non-additive effects is of interest because: (i) they contribute to an increase in the accuracy of the prediction of breeding values and the genetic response; (ii) they allow the definition of mate allocation procedures between candidates for selection; and (iii) they can be used to enhance non-additive genetic variation through the definition of appropriate crossbreeding or purebred breeding schemes. This study presents a review of methods for the incorporation of non-additive genetic effects into genomic selection procedures and their potential applications in the prediction of future performance, mate allocation, crossbreeding, and purebred selection. The work concludes with a brief outline of some ideas for future lines of that may help the standard inclusion of non-additive effects in genomic selection. PMID:29559995

  3. Non-additive Effects in Genomic Selection.

    PubMed

    Varona, Luis; Legarra, Andres; Toro, Miguel A; Vitezica, Zulma G

    2018-01-01

    In the last decade, genomic selection has become a standard in the genetic evaluation of livestock populations. However, most procedures for the implementation of genomic selection only consider the additive effects associated with SNP (Single Nucleotide Polymorphism) markers used to calculate the prediction of the breeding values of candidates for selection. Nevertheless, the availability of estimates of non-additive effects is of interest because: (i) they contribute to an increase in the accuracy of the prediction of breeding values and the genetic response; (ii) they allow the definition of mate allocation procedures between candidates for selection; and (iii) they can be used to enhance non-additive genetic variation through the definition of appropriate crossbreeding or purebred breeding schemes. This study presents a review of methods for the incorporation of non-additive genetic effects into genomic selection procedures and their potential applications in the prediction of future performance, mate allocation, crossbreeding, and purebred selection. The work concludes with a brief outline of some ideas for future lines of that may help the standard inclusion of non-additive effects in genomic selection.

  4. Kinetic studies of retinol addition radicals.

    PubMed

    El-Agamey, Ali; Fukuzumi, Shunichi; Naqvi, K Razi; McGarvey, David J

    2011-03-07

    Retinol neutral radicals (RS-retinol˙), generated from the reaction of retinol with 4-pyridylthiyl and 2-pyridylthiyl radicals in argon-saturated methanol, undergo β-elimination, which can be monitored via the slow secondary absorption rise at 380 nm attributed to the rearrangement of the unstable retinol neutral addition radicals to the more stable addition radicals. Rate constants for the β-elimination reactions (k(β)) of 4-PyrS-retinol˙ were measured at different temperatures and the Arrhenius equation for the reaction is described by log (k(β)/s(-1)) = (12.7 ± 0.2) - (54.3 ± 1.3)/θ, where θ = 2.3RT kJ mol(-1). The reactivities of retinol addition radicals (RS-retinol˙), generated from the reaction of retinol with various thiyl radicals, towards oxygen have also been investigated in methanol. In the presence of oxygen, the decay of RS-retinol˙ fits to biexponential kinetics and both observed rate constants for the RS-retinol˙ decay are oxygen-concentration dependent. This suggests that at least two thiyl addition radicals, formed from the reaction of RS˙ with retinol, undergo oxygen addition reactions. In light of the estimated rate constants for oxygen addition to RS-retinol˙ and RS-CAR˙ (CAR: carotenoid), the antioxidant-prooxidant properties of retinol are discussed.

  5. Building a Competitive Edge with Additive Manufacturing

    DTIC Science & Technology

    2013-02-14

    construct ceramic molds for complex metal parts using a 3D printing technique. They estimate the new 6 technique could eliminate all of the...processes. They include 3D printing and Additive Beam Techniques.15 Most Additive Manufacturing techniques are specific to certain classes of materials...9 Example Additive Manufacturing Techniques16 3D Printing Additive Beam Stereolithography (SLA) Direct Metal Laser Sintering (DMLS

  6. 78 FR 65617 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-01

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: 12/2/2013. [[Page 65618

  7. 27 CFR 19.318 - Addition of caramel to rum or brandy and addition of oak chips to spirits.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... or brandy and addition of oak chips to spirits. 19.318 Section 19.318 Alcohol, Tobacco Products and... PLANTS Production § 19.318 Addition of caramel to rum or brandy and addition of oak chips to spirits. Caramel possessing no material sweetening properties may be added to rum or brandy on bonded premises...

  8. ACADEMY OF SCIENCES AZERBAYDZHAN. INSTITUTE OF ADDITIVE CHEMISTRY. ADDITIVES AND LUBRICANTS, QUESTIONS OF SYNTHESIS, RESEARCH ON THE APPLICATION OF ADDITIVES AND LUBRICANTS, FUELS, AND POLYMER MATERIALS (SELECTED ARTICLES),

    DTIC Science & Technology

    an alkylphenol ); Synthesis and investigation of the new antioxidative INKhP-40 Additive; Synthesis and investigation of N-butylurethane-based antioxidative additive; and Synthesis of mixed esters of dithiophosphoric acid.

  9. Technetium Sorption By Cementitious Materials Under Reducing Conditions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kaplan, Daniel I.; Estes, Shanna L.; Arai, Yuji

    2013-07-18

    The objective of this study was to measure Tc sorption to cementitious materials under reducing conditions to simulate Saltstone Disposal Facility conditions. Earlier studies were conducted and the experimental conditions were found not to simulate those of the facility. Through a five month subcontract with Clemson University, sorption of {sup 99}Tc to four cementitious materials was examined within an anaerobic glovebag targeting a 0.1% H{sub 2}(g)/ 99.9% N{sub 2}(g) atmosphere. Early experiments based on Tc sorption and Eh indicated that 0.1% H{sub 2}(g) (a reductant) was necessary to preclude experimental impacts from O{sub 2}(g) diffusion into the glovebag. Preliminary datamore » to date (up to 56 days) indicates that sorption of {sup 99}Tc to cementitious materials increased with increasing slag content for simulated saltstone samples. This is consistent with the conceptual model that redox active sulfide groups within the reducing slag facilitate reduction of Tc(VII) to Tc(IV). These experiments differ from previous experiments where a 2% H{sub 2}(g) atmosphere was maintained (Kaplan et al., 2011 (SRNL-STI-2010-00668)). The impact of the 2% H{sub 2}(g) reducing atmosphere on this data was examined and determined to cause the reduction of Tc in experimental samples without slag. In the present ongoing study, after 56 days, Tc sorption by the 50-year old cement samples (no slag) was undetectable, whereas Tc sorption in the cementitious materials containing slag continues to increase with contact time (measured after 1, 4, 8, 19 and 56 days). Sorption was not consistent with spike concentrations and steady state has not been demonstrated after 56 days. The average conditional K{sub d} value for the Vault 2 cementitious material was 873 mL/g (17% slag), for the TR547 Saltstone (45% slag) the conditional K{sub d} was 168 mL/g, and for TR545 (90% slag) the conditional K{sub d} was 1,619 mL/g. It is anticipated that additional samples will be collected until

  10. 27 CFR 19.343 - Addition of oak chips to spirits and addition of caramel to brandy and rum.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... spirits and addition of caramel to brandy and rum. 19.343 Section 19.343 Alcohol, Tobacco Products and... PLANTS Storage § 19.343 Addition of oak chips to spirits and addition of caramel to brandy and rum. Oak... records. Caramel possessing no material sweetening properties may be added to rum or brandy in packages or...

  11. Additive Manufacturing of Aerospace Propulsion Components

    NASA Technical Reports Server (NTRS)

    Misra, Ajay K.; Grady, Joseph E.; Carter, Robert

    2015-01-01

    The presentation will provide an overview of ongoing activities on additive manufacturing of aerospace propulsion components, which included rocket propulsion and gas turbine engines. Future opportunities on additive manufacturing of hybrid electric propulsion components will be discussed.

  12. Evaluation of certain food additives.

    PubMed

    2012-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives, including flavouring agents, with a view to concluding as to safety concerns and to preparing specifications for identity and purity. The first part of the report contains a general discussion of the principles governing the toxicological evaluation of and assessment of dietary exposure to food additives, including flavouring agents. A summary follows of the Committee's evaluations of technical, toxicological and dietary exposure data for five food additives (magnesium dihydrogen diphosphate; mineral oil (medium and low viscosity) classes II and III; 3-phytase from Aspergillus niger expressed in Aspergillus niger; serine protease (chymotrypsin) from Nocardiopsis prasina expressed in Bacillus licheniformis; and serine protease (trypsin) from Fusarium oxysporum expressed in Fusarium venenatum) and 16 groups of flavouring agents (aliphatic and aromatic amines and amides; aliphatic and aromatic ethers; aliphatic hydrocarbons, alcohols, aldehydes, ketones, carboxylic acids and related esters, sulfides, disulfides and ethers containing furan substitution; aliphatic linear alpha,beta-unsaturated aldehydes, acids and related alcohols, acetals and esters; amino acids and related substances; epoxides; furfuryl alcohol and related substances; linear and branched-chain aliphatic, unsaturated, unconjugated alcohols, aldehydes, acids and related esters; miscellaneous nitrogen-containing substances; phenol and phenol derivatives; pyrazine derivatives; pyridine, pyrrole and quinoline derivatives; saturated aliphatic acyclic branched-chain primary alcohols, aldehydes and acids; simple aliphatic and aromatic sulfides and thiols; sulfur-containing heterocyclic compounds; and sulfur-substituted furan derivatives). Specifications for the following food additives were revised: ethyl cellulose, mineral oil (medium viscosity), modified starches and titanium

  13. Evaluation of certain food additives and contaminants.

    PubMed

    2001-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives and contaminants, with a view to recommending Acceptable Daily Intakes (ADIs) and tolerable intakes, respectively, and to prepare specifications for the identity and purity of food additives. The first part of the report contains a general discussion of the principles governing the toxicological evaluation of food additives and contaminants (including flavouring agents), and the establishment and revision of specifications. A summary follows of the Committee's evaluations of toxicological data on various specific food additives (furfural, paprika oleoresin, caramel colour II, cochineal extract, carmines, aspartame-acesulfame salt, D-tagatose, benzoyl peroxide, nitrous oxide, stearyl tartrate and trehalose), flavouring agents and contaminants (cadmium and tin), and of intake data on calcium from calcium salts of food additives. Annexed to the report are tables summarizing the Committee's recommendations for ADIs of the food additives and tolerable intakes of the contaminants considered, changes in the status of specifications of these food additives and specific flavouring agents, and further information required or desired.

  14. Gallium-67 scintigraphy and intraabdominal sepsis. Clinical experience in 140 patients with suspected intraabdominal abscess

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hopkins, G.B.; Kan, M.; Mende, C.W.

    In 140 patients with suspected intraabdominal abscess, studies were made using gallium-67 citrate and technetium-99m labeled radiopharmaceuticals. Gallium-67 scintigrams correctly localized 52 of 56 intraabdominal abscesses confirmed at surgical operation or necropsy. In an additional 20 patients in whom findings on scintigrams were abnormal, there were clinically established infections. Sixty-one patients in whom findings on scintigrams were normal were conservatively managed and discharged from the hospital; none proved to have an abscess. Four false-negative and three false-positive studies were recorded. Gallium-67 scintigraphy is a useful noninvasive diagnostic adjunct that should be employed early in the evaluation of patients with suspectedmore » intraabdominal sepsis.« less

  15. A comparative study of indium-111 DTPA radionuclide and iothalamate meglumine roentgenographic arthrography in the evaluation of painful total hip arthroplasty

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Maxon, H.R.; Schneider, H.J.; Hopson, C.N.

    1989-08-01

    Fifteen patients with painful total hip prostheses were referred for nuclear medicine and roentgenographic arthrography studies to exclude loosening of the acetabular and/or the femoral component. A new radioisotopic technique suitable for the evaluation of both components was developed using dual-isotope single-photon tomography with {sup 99m}technetium methylene diphosphonate bone imaging and indium-111 diethylenetriaminepentacetic acid arthrography. Thirteen of the 15 subjects were subsequently treated with additional surgery. The surgical findings were compared with the nuclear medicine and roentgenographic results. The overall diagnostic accuracy of both arthrographic procedures was approximately 80%, but the roentgenographic arthrogram was more sensitive and the radionuclide arthrogrammore » was more specific.« less

  16. Evaluation of antistripping additives.

    DOT National Transportation Integrated Search

    1989-01-01

    Several chemical antistripping additives were used in field installations and compared to a similar installation using hydrated lime. The performance of the installations was monitored periodically, and material that was sampled during construction w...

  17. VARIABLE SELECTION IN NONPARAMETRIC ADDITIVE MODELS

    PubMed Central

    Huang, Jian; Horowitz, Joel L.; Wei, Fengrong

    2010-01-01

    We consider a nonparametric additive model of a conditional mean function in which the number of variables and additive components may be larger than the sample size but the number of nonzero additive components is “small” relative to the sample size. The statistical problem is to determine which additive components are nonzero. The additive components are approximated by truncated series expansions with B-spline bases. With this approximation, the problem of component selection becomes that of selecting the groups of coefficients in the expansion. We apply the adaptive group Lasso to select nonzero components, using the group Lasso to obtain an initial estimator and reduce the dimension of the problem. We give conditions under which the group Lasso selects a model whose number of components is comparable with the underlying model, and the adaptive group Lasso selects the nonzero components correctly with probability approaching one as the sample size increases and achieves the optimal rate of convergence. The results of Monte Carlo experiments show that the adaptive group Lasso procedure works well with samples of moderate size. A data example is used to illustrate the application of the proposed method. PMID:21127739

  18. Food Additives and Hyperkinesis

    ERIC Educational Resources Information Center

    Wender, Ester H.

    1977-01-01

    The hypothesis that food additives are causally associated with hyperkinesis and learning disabilities in children is reviewed, and available data are summarized. Available from: American Medical Association 535 North Dearborn Street Chicago, Illinois 60610. (JG)

  19. 14 CFR 1203.406 - Additional classification factors.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... PROGRAM Guides for Original Classification § 1203.406 Additional classification factors. In determining the appropriate classification category, the following additional factors should be considered: (a... 14 Aeronautics and Space 5 2011-01-01 2010-01-01 true Additional classification factors. 1203.406...

  20. Manipulating crystallization with molecular additives.

    PubMed

    Shtukenberg, Alexander G; Lee, Stephanie S; Kahr, Bart; Ward, Michael D

    2014-01-01

    Given the importance of organic crystals in a wide range of industrial applications, the chemistry, biology, materials science, and chemical engineering communities have focused considerable attention on developing methods to control crystal structure, size, shape, and orientation. Tailored additives have been used to control crystallization to great effect, presumably by selectively binding to particular crystallographic surfaces and sites. However, substantial knowledge gaps still exist in the fundamental mechanisms that govern the formation and growth of organic crystals in both the absence and presence of additives. In this review, we highlight research discoveries that reveal the role of additives, either introduced by design or present adventitiously, on various stages of formation and growth of organic crystals, including nucleation, dislocation spiral growth mechanisms, growth inhibition, and nonclassical crystal morphologies. The insights from these investigations and others of their kind are likely to guide the development of innovative methods to manipulate crystallization for a wide range of materials and applications.

  1. Additive manufacturing of hybrid circuits

    DOE PAGES

    Bell, Nelson S.; Sarobol, Pylin; Cook, Adam; ...

    2016-03-26

    There is a rising interest in developing functional electronics using additively manufactured components. Considerations in materials selection and pathways to forming hybrid circuits and devices must demonstrate useful electronic function; must enable integration; and must complement the complex shape, low cost, high volume, and high functionality of structural but generally electronically passive additively manufactured components. This article reviews several emerging technologies being used in industry and research/development to provide integration advantages of fabricating multilayer hybrid circuits or devices. First, we review a maskless, noncontact, direct write (DW) technology that excels in the deposition of metallic colloid inks for electrical interconnects.more » Second, we review a complementary technology, aerosol deposition (AD), which excels in the deposition of metallic and ceramic powder as consolidated, thick conformal coatings and is additionally patternable through masking. As a result, we show examples of hybrid circuits/devices integrated beyond 2-D planes, using combinations of DW or AD processes and conventional, established processes.« less

  2. Large Scale Metal Additive Techniques Review

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nycz, Andrzej; Adediran, Adeola I; Noakes, Mark W

    2016-01-01

    In recent years additive manufacturing made long strides toward becoming a main stream production technology. Particularly strong progress has been made in large-scale polymer deposition. However, large scale metal additive has not yet reached parity with large scale polymer. This paper is a review study of the metal additive techniques in the context of building large structures. Current commercial devices are capable of printing metal parts on the order of several cubic feet compared to hundreds of cubic feet for the polymer side. In order to follow the polymer progress path several factors are considered: potential to scale, economy, environmentmore » friendliness, material properties, feedstock availability, robustness of the process, quality and accuracy, potential for defects, and post processing as well as potential applications. This paper focuses on current state of art of large scale metal additive technology with a focus on expanding the geometric limits.« less

  3. Additive manufactured x-ray optics for astronomy

    NASA Astrophysics Data System (ADS)

    Atkins, Carolyn; Feldman, Charlotte; Brooks, David; Watson, Stephen; Cochrane, William; Roulet, Melanie; Doel, Peter; Willingale, Richard; Hugot, Emmanuel

    2017-08-01

    Additive manufacturing, more commonly known as 3D printing, has become a commercially established technology for rapid prototyping and the fabrication of bespoke intricate parts. Optical components, such as mirrors and lenses, are now being fabricated via additive manufacturing, where the printed substrate is polished in a post-processing step. One application of additively manufactured optics could be within the astronomical X-ray community, where there is a growing need to demonstrate thin, lightweight, high precision optics for a beyond Chandra style mission. This paper will follow a proof-of-concept investigation, sponsored by the UK Space Agency's National Space Technology Programme, into the feasibility of applying additive manufacturing in the production of thin, lightweight, precision X-ray optics for astronomy. One of the benefits of additive manufacturing is the ability to construct intricate lightweighting, which can be optimised to minimise weight while ensuring rigidity. This concept of optimised lightweighting will be applied to a series of polished additively manufactured test samples and experimental data from these samples, including an assessment of the optical quality and the magnitude of any print-through, will be presented. In addition, the finite element analysis optimisations of the lightweighting development will be discussed.

  4. Functional Generalized Additive Models.

    PubMed

    McLean, Mathew W; Hooker, Giles; Staicu, Ana-Maria; Scheipl, Fabian; Ruppert, David

    2014-01-01

    We introduce the functional generalized additive model (FGAM), a novel regression model for association studies between a scalar response and a functional predictor. We model the link-transformed mean response as the integral with respect to t of F { X ( t ), t } where F (·,·) is an unknown regression function and X ( t ) is a functional covariate. Rather than having an additive model in a finite number of principal components as in Müller and Yao (2008), our model incorporates the functional predictor directly and thus our model can be viewed as the natural functional extension of generalized additive models. We estimate F (·,·) using tensor-product B-splines with roughness penalties. A pointwise quantile transformation of the functional predictor is also considered to ensure each tensor-product B-spline has observed data on its support. The methods are evaluated using simulated data and their predictive performance is compared with other competing scalar-on-function regression alternatives. We illustrate the usefulness of our approach through an application to brain tractography, where X ( t ) is a signal from diffusion tensor imaging at position, t , along a tract in the brain. In one example, the response is disease-status (case or control) and in a second example, it is the score on a cognitive test. R code for performing the simulations and fitting the FGAM can be found in supplemental materials available online.

  5. 42 CFR 417.592 - Additional benefits requirement.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 3 2010-10-01 2010-10-01 false Additional benefits requirement. 417.592 Section... HEALTH CARE PREPAYMENT PLANS Medicare Payment: Risk Basis § 417.592 Additional benefits requirement. (a... benefits. Provide its Medicare enrollees with additional benefits in accordance with paragraph (c) of this...

  6. 7 CFR 3015.161 - Additional requirements.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 15 2010-01-01 2010-01-01 false Additional requirements. 3015.161 Section 3015.161 Agriculture Regulations of the Department of Agriculture (Continued) OFFICE OF THE CHIEF FINANCIAL OFFICER, DEPARTMENT OF AGRICULTURE UNIFORM FEDERAL ASSISTANCE REGULATIONS Property § 3015.161 Additional requirements...

  7. 76 FR 23997 - Procurement List; Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-29

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the.../30/2011. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, Jefferson...

  8. 75 FR 52723 - Procurement List Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the.../23/2010. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, Jefferson...

  9. 75 FR 72815 - Procurement List Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-26

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: 12/20/2010. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  10. 78 FR 4133 - Procurement List; Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-18

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the.../18/2013. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, Jefferson...

  11. 78 FR 2378 - Procurement List, Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-01-11

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List, Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the.../11/2013. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, Jefferson...

  12. 75 FR 31769 - Procurement List Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-04

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: 7/5/2010. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  13. 77 FR 47822 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-10

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: September 10, 2012. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  14. 76 FR 35415 - Procurement List; Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-17

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the.../18/2011. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, Jefferson...

  15. 77 FR 15736 - Procurement List; Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-16

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the.../16/2012. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, Jefferson...

  16. 49 CFR 1108.12 - Additional matters.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 8 2010-10-01 2010-10-01 false Additional matters. 1108.12 Section 1108.12 Transportation Other Regulations Relating to Transportation (Continued) SURFACE TRANSPORTATION BOARD, DEPARTMENT... JURISDICTION OF THE SURFACE TRANSPORTATION BOARD § 1108.12 Additional matters. Where an arbitration demand is...

  17. 49 CFR 1108.12 - Additional matters.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 8 2012-10-01 2012-10-01 false Additional matters. 1108.12 Section 1108.12 Transportation Other Regulations Relating to Transportation (Continued) SURFACE TRANSPORTATION BOARD, DEPARTMENT... JURISDICTION OF THE SURFACE TRANSPORTATION BOARD § 1108.12 Additional matters. Where an arbitration demand is...

  18. 49 CFR 1108.12 - Additional matters.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 8 2011-10-01 2011-10-01 false Additional matters. 1108.12 Section 1108.12 Transportation Other Regulations Relating to Transportation (Continued) SURFACE TRANSPORTATION BOARD, DEPARTMENT... JURISDICTION OF THE SURFACE TRANSPORTATION BOARD § 1108.12 Additional matters. Where an arbitration demand is...

  19. 77 FR 41377 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the... furnished by nonprofit agencies employing persons who are blind or have other severe disabilities. DATES...

  20. 76 FR 40341 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-08

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the... furnished by nonprofit agencies employing persons who are blind or have other severe disabilities. DATES...

  1. Advances in biobased lubricant additive development

    USDA-ARS?s Scientific Manuscript database

    Lubricant formulations comprise two categories of ingredients: base oils and additives. Depending on its application, a formulation may contain one or more from each category. Additives are the most expensive ingredients of lubricant formulations and, for some applications, can comprise 25 to 40% w/...

  2. 20 CFR 901.72 - Additional rules.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 4 2012-04-01 2012-04-01 false Additional rules. 901.72 Section 901.72 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES REGULATIONS GOVERNING THE PERFORMANCE OF... additional rules regarding the enrollment of actuaries. [76 FR 17776, Mar. 31, 2011] ...

  3. 20 CFR 901.72 - Additional rules.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 4 2014-04-01 2014-04-01 false Additional rules. 901.72 Section 901.72 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES REGULATIONS GOVERNING THE PERFORMANCE OF... additional rules regarding the enrollment of actuaries. [76 FR 17776, Mar. 31, 2011] ...

  4. 20 CFR 901.72 - Additional rules.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 4 2013-04-01 2013-04-01 false Additional rules. 901.72 Section 901.72 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES REGULATIONS GOVERNING THE PERFORMANCE OF... additional rules regarding the enrollment of actuaries. [76 FR 17776, Mar. 31, 2011] ...

  5. 46 CFR 308.502 - Additional insurance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 8 2014-10-01 2014-10-01 false Additional insurance. 308.502 Section 308.502 Shipping MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EMERGENCY OPERATIONS WAR RISK INSURANCE War Risk Cargo Insurance Introduction § 308.502 Additional insurance. The assured may place increased value or...

  6. 76 FR 19751 - Procurement List; Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-08

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the.../9/2011. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, Jefferson...

  7. 40 CFR 80.162 - Additive compositional data.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 40 Protection of Environment 16 2011-07-01 2011-07-01 false Additive compositional data. 80.162... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.162 Additive compositional data... gasoline detergency requirements of this subpart, the compositional data to be supplied to EPA by the...

  8. 40 CFR 80.162 - Additive compositional data.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 17 2013-07-01 2013-07-01 false Additive compositional data. 80.162... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.162 Additive compositional data... gasoline detergency requirements of this subpart, the compositional data to be supplied to EPA by the...

  9. 40 CFR 80.162 - Additive compositional data.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Additive compositional data. 80.162... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.162 Additive compositional data... gasoline detergency requirements of this subpart, the compositional data to be supplied to EPA by the...

  10. 40 CFR 80.162 - Additive compositional data.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 17 2012-07-01 2012-07-01 false Additive compositional data. 80.162... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.162 Additive compositional data... gasoline detergency requirements of this subpart, the compositional data to be supplied to EPA by the...

  11. 40 CFR 80.162 - Additive compositional data.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 17 2014-07-01 2014-07-01 false Additive compositional data. 80.162... (CONTINUED) REGULATION OF FUELS AND FUEL ADDITIVES Detergent Gasoline § 80.162 Additive compositional data... gasoline detergency requirements of this subpart, the compositional data to be supplied to EPA by the...

  12. Photoactive devices including porphyrinoids with coordinating additives

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Forrest, Stephen R; Zimmerman, Jeramy; Yu, Eric K

    Coordinating additives are included in porphyrinoid-based materials to promote intermolecular organization and improve one or more photoelectric characteristics of the materials. The coordinating additives are selected from fullerene compounds and organic compounds having free electron pairs. Combinations of different coordinating additives can be used to tailor the characteristic properties of such porphyrinoid-based materials, including porphyrin oligomers. Bidentate ligands are one type of coordinating additive that can form coordination bonds with a central metal ion of two different porphyrinoid compounds to promote porphyrinoid alignment and/or pi-stacking. The coordinating additives can shift the absorption spectrum of a photoactive material toward higher wavelengths,more » increase the external quantum efficiency of the material, or both.« less

  13. The grays of medical device color additives.

    PubMed

    Seidman, Brenda

    2014-01-01

    The United States' medical device color additive regulations are unknown to some, and confusing to many. This article reviews statutory language on color additives in the Federal Food, Drug, and Cosmetic Act (FFDCA), as amended, including the Delaney Clause on carcinogenicity; color additive regulatory language as it relates to medical devices in Title 21 of the Code of Federal Regulations (C.F.R.), Parts 70-82; reports on the Food and Drug Administration's (FDA's) likely current and historical practices in dealing with color additives in medical devices; and speculates on what may have given rise to decades of seemingly ad hoc color additives practices, which may now be difficult to reconstruct and satisfactorily modify. Also addressed is the Center for Devices and Radiological Health's (CDRH's) recent publicly-vetted approach to color additives in Section 7 of its April 2013 draft guidance, Use of International Standard ISO-10993, "Biological Evaluation of Medical Devices Part 1: Evaluation and Testing," which the author concludes is a change in the right direction, but which, at least in its current draft form, is not a fix to the CDRH's color additives dilemma. Lastly, the article suggests what the CDRH might consider in further developing a new approach to color additives. Such an approach would treat color additives as if they were any other potentially toxic group of chemicals, and could be fashioned in such a way that the CDRH could still satisfy the broad aspects of Congressional color additives mandates, and.yet be consistent with ISO 10993. In doing this, the CDRH would need to recommend a more directed use of its Quality System Regulation, 21 C.F.R. Part 820, for material and vendor qualification and validation in general; approach Congress for needed statutory changes; or make administrative changes. In order for any approach to be successful, whether it is a new twist on past practices, or an entirely new path forward, the FDA must, to the best of its

  14. 76 FR 76952 - Procurement List Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-09

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: January 9, 2012. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely...

  15. 78 FR 41916 - Procurement List Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-12

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the...: August 12, 2013. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, 1401 S...

  16. 77 FR 49783 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-17

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective 9/17/2012. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  17. 78 FR 16476 - Procurement List Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-15

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: 4/15/2013. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  18. 78 FR 45183 - Procurement List Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-26

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: 8/26/2013 ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  19. 78 FR 25971 - Procurement List, Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-03

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List, Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: 6/3/2013. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, 1401 S...

  20. 78 FR 32632 - Procurement List; Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-31

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Addition AGENCY: Committee for Purchase from People Who are Blind or Severely Disabled. ACTION: Addition to the.../1/2013. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, 1401 S...

  1. 78 FR 34351 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-07

    .... ADDRESSES: Committee for Purchase from People Who are Blind or Severely Disabled, 1401 S. Clark Street... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase from People Who are Blind or Severely Disabled. ACTION: Additions to the...

  2. 78 FR 63967 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-25

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: 11/25/2013. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled, 1401 S...

  3. 78 FR 59658 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-27

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective October 28, 2013. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  4. 45 CFR 400.106 - Additional services.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... CHILDREN AND FAMILIES, DEPARTMENT OF HEALTH AND HUMAN SERVICES REFUGEE RESETTLEMENT PROGRAM Refugee Medical Assistance Scope of Medical Services § 400.106 Additional services. If a State or local jurisdiction provides additional medical services beyond the scope of the State's Medicaid program to destitute residents of the...

  5. 75 FR 70908 - Procurement List; Addition

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-19

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Addition AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Addition to the...: Effective Date: 12/20/2010. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  6. 77 FR 27736 - Procurement List Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-11

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: 6/11/2012. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  7. 77 FR 2962 - Procurement List Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-01-20

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: 2/20/2012. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  8. 75 FR 75461 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-12-03

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: 1/3/2011. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  9. 77 FR 66181 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-02

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: 12/3/2012. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  10. 75 FR 43152 - Procurement List Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-23

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: 8/23/2010. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  11. 12 CFR 619.9010 - Additional security.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 12 Banks and Banking 7 2014-01-01 2014-01-01 false Additional security. 619.9010 Section 619.9010 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM DEFINITIONS § 619.9010 Additional security. Supplementary collateral to the primary security taken in connection with the loan. ...

  12. 77 FR 62220 - Procurement List; Additions

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-12

    ... COMMITTEE FOR PURCHASE FROM PEOPLE WHO ARE BLIND OR SEVERELY DISABLED Procurement List; Additions AGENCY: Committee for Purchase From People Who Are Blind or Severely Disabled. ACTION: Additions to the...: Effective Date: 11/12/2012. ADDRESSES: Committee for Purchase From People Who Are Blind or Severely Disabled...

  13. 46 CFR 308.502 - Additional insurance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 8 2010-10-01 2010-10-01 false Additional insurance. 308.502 Section 308.502 Shipping MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EMERGENCY OPERATIONS WAR RISK INSURANCE War Risk Cargo Insurance I-Introduction § 308.502 Additional insurance. The assured may place increased value or...

  14. 46 CFR 308.502 - Additional insurance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 8 2011-10-01 2011-10-01 false Additional insurance. 308.502 Section 308.502 Shipping MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EMERGENCY OPERATIONS WAR RISK INSURANCE War Risk Cargo Insurance I-Introduction § 308.502 Additional insurance. The assured may place increased value or...

  15. 46 CFR 308.502 - Additional insurance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 8 2013-10-01 2013-10-01 false Additional insurance. 308.502 Section 308.502 Shipping MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EMERGENCY OPERATIONS WAR RISK INSURANCE War Risk Cargo Insurance I-Introduction § 308.502 Additional insurance. The assured may place increased value or...

  16. 46 CFR 308.502 - Additional insurance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 8 2012-10-01 2012-10-01 false Additional insurance. 308.502 Section 308.502 Shipping MARITIME ADMINISTRATION, DEPARTMENT OF TRANSPORTATION EMERGENCY OPERATIONS WAR RISK INSURANCE War Risk Cargo Insurance I-Introduction § 308.502 Additional insurance. The assured may place increased value or...

  17. 42 CFR 65.9 - Additional conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Additional conditions. 65.9 Section 65.9 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL INSTITUTE OF ENVIRONMENTAL HEALTH SCIENCES HAZARDOUS WASTE WORKER TRAINING § 65.9 Additional...

  18. 42 CFR 66.115 - Additional conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Additional conditions. 66.115 Section 66.115 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.115 Additional conditions. The Secretary may with...

  19. 42 CFR 65.9 - Additional conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Additional conditions. 65.9 Section 65.9 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL INSTITUTE OF ENVIRONMENTAL HEALTH SCIENCES HAZARDOUS WASTE WORKER TRAINING § 65.9 Additional...

  20. 42 CFR 65.9 - Additional conditions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Additional conditions. 65.9 Section 65.9 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL INSTITUTE OF ENVIRONMENTAL HEALTH SCIENCES HAZARDOUS WASTE WORKER TRAINING § 65.9 Additional...

  1. 42 CFR 66.115 - Additional conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Additional conditions. 66.115 Section 66.115 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.115 Additional conditions. The Secretary may with...

  2. 42 CFR 65.9 - Additional conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Additional conditions. 65.9 Section 65.9 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL INSTITUTE OF ENVIRONMENTAL HEALTH SCIENCES HAZARDOUS WASTE WORKER TRAINING § 65.9 Additional...

  3. 42 CFR 66.115 - Additional conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Additional conditions. 66.115 Section 66.115 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES FELLOWSHIPS, INTERNSHIPS, TRAINING NATIONAL RESEARCH SERVICE AWARDS Direct Awards § 66.115 Additional conditions. The Secretary may with...

  4. 12 CFR 619.9010 - Additional security.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 12 Banks and Banking 6 2010-01-01 2010-01-01 false Additional security. 619.9010 Section 619.9010 Banks and Banking FARM CREDIT ADMINISTRATION FARM CREDIT SYSTEM DEFINITIONS § 619.9010 Additional security. Supplementary collateral to the primary security taken in connection with the loan. ...

  5. 77 FR 41899 - Indirect Food Additives: Polymers

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-17

    .... FDA-2012-F-0031] Indirect Food Additives: Polymers AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA or the Agency) is amending the food additive... FR 9608), FDA announced that a food additive petition (FAP 1B4783) had been filed by the American...

  6. A secular technetium-molybdenum generator

    NASA Astrophysics Data System (ADS)

    Araujo, Wagner L.; Campos, Tarcisio P. R.

    2015-05-01

    A compact secular molybdenium generator is subject of this paper. This generator represents a nuclear system that comprises a hydrogen-isotopes fusor, moderator, reflector and shield. Deuterium fusion reactions in a tritiated or deuterated target provide the neutron source. A moderation fluid slowdown the neutron energy which increases 98Mo(n,γ)99Mo capture reaction rates. Neutron reflection minimizes the neutron escape and the radiation shield encloses the device. The neutron yield calculation along with electromagnetic and nuclear simulations were addressed. Results revealed the accelerator equipotential surfaces ranging from -30 to 150 kV, the ion trajectories and the energy beam profile define a deuteron current of 1 A with energy of 180 keV at the target, the spatial distribution of the neutron flux, and the 99Mo and 99mTc activities in function of transmuter operation time. The kinetics of the 99mTc correlated to its precursor activity demonstrates a secular equilibrium providing 2 Ci in a operational time of 150 h. As conclusion, the investigated nuclear and electromagnetic features have demonstrated that such generator shall have a notable potential for feeding the 99mTc clinical application.

  7. Technetium-99m generator system

    DOEpatents

    Mirzadeh, Saed; Knapp, Jr., Furn F.; Collins, Emory D.

    1998-01-01

    A .sup.99 Mo/.sup.99m Tc generator system includes a sorbent column loaded with a composition containing .sup.99 Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating .sup.99m Tc eluted from the sorbent column. A method of preparing a concentrated solution of .sup.99m Tc includes the general steps of: a. providing a sorbent column loaded with a composition containing .sup.99 Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; b. eluting the sorbent column with a salt solution to elute .sup.99m Tc from the sorbent and to trap and concentrate the eluted .sup.99m Tc on the ion-exchange column; and c. eluting the concentrated .sup.99m Tc from the ion-exchange column with a solution comprising a reductive complexing agent.

  8. Technetium-99m generator system

    DOEpatents

    Mirzadeh, S.; Knapp, F.F. Jr.; Collins, E.D.

    1998-06-30

    A {sup 99}Mo/{sup 99m}Tc generator system includes a sorbent column loaded with a composition containing {sup 99}Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating {sup 99m}Tc eluted from the sorbent column. A method of preparing a concentrated solution of {sup 99m}Tc includes the general steps of: (a) providing a sorbent column loaded with a composition containing {sup 99}Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; (b) eluting the sorbent column with a salt solution to elute {sup 99m}Tc from the sorbent and to trap and concentrate the eluted {sup 99m}Tc on the ion-exchange column; and (c) eluting the concentrated {sup 99m}Tc from the ion-exchange column with a solution comprising a reductive complexing agent. 1 fig.

  9. Allergic and immunologic reactions to food additives.

    PubMed

    Gultekin, Fatih; Doguc, Duygu Kumbul

    2013-08-01

    For centuries, food additives have been used for flavouring, colouring and extension of the useful shelf life of food, as well as the promotion of food safety. During the last 20 years, the studies implicating the additives contained in foods and medicine as a causative factor of allergic reactions have been proliferated considerably. In this review, we aimed to overview all of the food additives which were approved to consume in EU and find out how common and serious allergic reactions come into existence following the consuming of food additives.

  10. Additive manufactured serialization

    DOEpatents

    Bobbitt, III, John T.

    2017-04-18

    Methods for forming an identifying mark in a structure are described. The method is used in conjunction with an additive manufacturing method and includes the alteration of a process parameter during the manufacturing process. The method can form in a unique identifying mark within or on the surface of a structure that is virtually impossible to be replicated. Methods can provide a high level of confidence that the identifying mark will remain unaltered on the formed structure.

  11. Developing Multiplicative Thinking from Additive Reasoning

    ERIC Educational Resources Information Center

    Tobias, Jennifer M.; Andreasen, Janet B.

    2013-01-01

    As students progress through elementary school, they encounter mathematics concepts that shift from additive to multiplicative situations (NCTM 2000). When they encounter fraction problems that require multiplicative thinking, they tend to incorrectly extend additive properties from whole numbers (Post et al. 1985). As a result, topics such as …

  12. 18 CFR 1314.10 - Additional provisions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 2 2010-04-01 2010-04-01 false Additional provisions. 1314.10 Section 1314.10 Conservation of Power and Water Resources TENNESSEE VALLEY AUTHORITY BOOK-ENTRY PROCEDURES FOR TVA POWER SECURITIES ISSUED THROUGH THE FEDERAL RESERVE BANKS § 1314.10 Additional provisions...

  13. 18 CFR 1314.10 - Additional provisions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 18 Conservation of Power and Water Resources 2 2011-04-01 2011-04-01 false Additional provisions. 1314.10 Section 1314.10 Conservation of Power and Water Resources TENNESSEE VALLEY AUTHORITY BOOK-ENTRY PROCEDURES FOR TVA POWER SECURITIES ISSUED THROUGH THE FEDERAL RESERVE BANKS § 1314.10 Additional provisions...

  14. The Additive Coloration of Alkali Halides

    ERIC Educational Resources Information Center

    Jirgal, G. H.; and others

    1969-01-01

    Describes the construction and use of an inexpensive, vacuum furnace designed to produce F-centers in alkali halide crystals by additive coloration. The method described avoids corrosion or contamination during the coloration process. Examination of the resultant crystals is discussed and several experiments using additively colored crystals are…

  15. DECISION-MAKING, SCIENCE AND GASOLINE ADDITIVES

    EPA Science Inventory


    Methyl-tert butyl ether (MTBE) has been used as a gasoline additive to serve two major purposes. The first use was as an octane-enhancer to replace organic lead, beginning in 1979. The second use, which began about 1992, was as an oxygenated additive to meet requirements ...

  16. 45 CFR 96.132 - Additional agreements.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 45 Public Welfare 1 2010-10-01 2010-10-01 false Additional agreements. 96.132 Section 96.132... Abuse Prevention and Treatment Block Grant § 96.132 Additional agreements. (a) With respect to... facility in its funding agreement. (c) The State shall coordinate prevention and treatment activities with...

  17. 45 CFR 96.132 - Additional agreements.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 1 2011-10-01 2011-10-01 false Additional agreements. 96.132 Section 96.132... Abuse Prevention and Treatment Block Grant § 96.132 Additional agreements. (a) With respect to... facility in its funding agreement. (c) The State shall coordinate prevention and treatment activities with...

  18. 18 CFR 33.10 - Additional information.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 18 Conservation of Power and Water Resources 1 2010-04-01 2010-04-01 false Additional information. 33.10 Section 33.10 Conservation of Power and Water Resources FEDERAL ENERGY REGULATORY COMMISSION... § 33.10 Additional information. The Director of the Office of Energy Market Regulation, or his designee...

  19. 20 CFR 901.72 - Additional rules.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Additional rules. 901.72 Section 901.72 Employees' Benefits JOINT BOARD FOR THE ENROLLMENT OF ACTUARIES REGULATIONS GOVERNING THE PERFORMANCE OF... additional rules regarding the enrollment of actuaries. Effective Date Note: At 76 FR 17776, Mar. 31, 2011...

  20. Evaluation of certain food additives.

    PubMed

    2009-01-01

    This report represents the conclusions of a Joint FAO/WHO Expert Committee convened to evaluate the safety of various food additives, including flavouring agents, with a view to recommending acceptable daily intakes (ADIs) and to preparing specifications for identity and purity. The first part of the report contains a general discussion of the principles governing the toxicological evaluation and assessment of intake of food additives (in particular, flavouring agents). A summary follows of the Committee's evaluations of technical, toxicological and intake data for certain food additives (asparaginase from Aspergillus niger expressed in A. niger, calcium lignosulfonate (40-65), ethyl lauroyl arginate, paprika extract, phospholipase C expressed in Pichia pastoris, phytosterols, phytostanols and their esters, polydimethylsiloxane, steviol glycosides and sulfites [assessment of dietary exposure]) and 10 groups of related flavouring agents (aliphatic branched-chain saturated and unsaturated alcohols, aldehydes, acids and related esters; aliphatic linear alpha,beta-unsaturated aldehydes, acids and related alcohols, acetals and esters; aliphatic secondary alcohols, ketones and related esters; alkoxy-substituted allylbenzenes present in foods and essential oils and used as flavouring agents; esters of aliphatic acyclic primary alcohols with aliphatic linear saturated carboxylic acids; furan-substituted aliphatic hydrocarbons, alcohols, aldehydes, ketones, carboxylic acids and related esters, sulfides, disulfides and ethers; miscellaneous nitrogen-containing substances; monocyclic and bicyclic secondary alcohols, ketones and related esters; hydroxy- and alkoxy-substituted benzyl derivatives; and substances structurally related to menthol). Specifications for the following food additives were revised: canthaxanthin; carob bean gum and carob bean gum (clarified); chlorophyllin copper complexes, sodium and potassium salts; Fast Green FCF; guar gum and guar gum (clarified

  1. Tinkertoy Color-Addition Device.

    ERIC Educational Resources Information Center

    Ferguson, Joe L.

    1995-01-01

    Describes construction and use of a simple home-built device, using an overhead projector, for use in demonstrations of the addition of various combinations of red, green, and blue light. Useful in connection with discussions of color, color vision, or color television. (JRH)

  2. On the addition theorem of spherical functions

    NASA Astrophysics Data System (ADS)

    Shkodrov, V. G.

    The addition theorem of spherical functions is expressed in two reference systems, viz., an inertial system and a system rigidly fixed to a planet. A generalized addition theorem of spherical functions and a particular addition theorem for the rigidly fixed system are derived. The results are applied to the theory of a planetary potential.

  3. 10 CFR 810.14 - Additional information.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Additional information. 810.14 Section 810.14 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.14 Additional information. The Department of Energy may at any time require a person engaging in any generally or specifically authorized...

  4. 10 CFR 810.14 - Additional information.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Additional information. 810.14 Section 810.14 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.14 Additional information. The Department of Energy may at any time require a person engaging in any generally or specifically authorized...

  5. 10 CFR 810.14 - Additional information.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Additional information. 810.14 Section 810.14 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.14 Additional information. The Department of Energy may at any time require a person engaging in any generally or specifically authorized...

  6. 10 CFR 810.14 - Additional information.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Additional information. 810.14 Section 810.14 Energy DEPARTMENT OF ENERGY ASSISTANCE TO FOREIGN ATOMIC ENERGY ACTIVITIES § 810.14 Additional information. The Department of Energy may at any time require a person engaging in any generally or specifically authorized...

  7. 42 CFR 59.12 - Additional conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Additional conditions. 59.12 Section 59.12 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Project Grants for Family Planning Services § 59.12 Additional conditions. The Secretary may, with...

  8. 42 CFR 59.12 - Additional conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Additional conditions. 59.12 Section 59.12 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Project Grants for Family Planning Services § 59.12 Additional conditions. The Secretary may, with...

  9. 42 CFR 59.214 - Additional conditions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Additional conditions. 59.214 Section 59.214 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Grants for Family Planning Service Training § 59.214 Additional conditions. The Secretary may with...

  10. 42 CFR 59.12 - Additional conditions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 42 Public Health 1 2014-10-01 2014-10-01 false Additional conditions. 59.12 Section 59.12 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Project Grants for Family Planning Services § 59.12 Additional conditions. The Secretary may, with...

  11. 42 CFR 59.12 - Additional conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Additional conditions. 59.12 Section 59.12 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Project Grants for Family Planning Services § 59.12 Additional conditions. The Secretary may, with...

  12. 42 CFR 59.12 - Additional conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Additional conditions. 59.12 Section 59.12 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Project Grants for Family Planning Services § 59.12 Additional conditions. The Secretary may, with...

  13. 42 CFR 59.214 - Additional conditions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 42 Public Health 1 2013-10-01 2013-10-01 false Additional conditions. 59.214 Section 59.214 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Grants for Family Planning Service Training § 59.214 Additional conditions. The Secretary may with...

  14. 42 CFR 59.214 - Additional conditions.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 42 Public Health 1 2010-10-01 2010-10-01 false Additional conditions. 59.214 Section 59.214 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Grants for Family Planning Service Training § 59.214 Additional conditions. The Secretary may with...

  15. 42 CFR 59.214 - Additional conditions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 42 Public Health 1 2012-10-01 2012-10-01 false Additional conditions. 59.214 Section 59.214 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Grants for Family Planning Service Training § 59.214 Additional conditions. The Secretary may with...

  16. 42 CFR 59.214 - Additional conditions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 42 Public Health 1 2011-10-01 2011-10-01 false Additional conditions. 59.214 Section 59.214 Public Health PUBLIC HEALTH SERVICE, DEPARTMENT OF HEALTH AND HUMAN SERVICES GRANTS GRANTS FOR FAMILY PLANNING SERVICES Grants for Family Planning Service Training § 59.214 Additional conditions. The Secretary may with...

  17. Contexts for Column Addition and Subtraction

    ERIC Educational Resources Information Center

    Lopez Fernandez, Jorge M.; Velazquez Estrella, Aileen

    2011-01-01

    In this article, the authors discuss their approach to column addition and subtraction algorithms. Adapting an original idea of Paul Cobb and Erna Yackel's from "A Contextual Investigation of Three-Digit Addition and Subtraction" related to packing and unpacking candy in a candy factory, the authors provided an analogous context by…

  18. 21 CFR 173.310 - Boiler water additives.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Boiler water additives. 173.310 Section 173.310... Boiler water additives. Boiler water additives may be safely used in the preparation of steam that will... Total not to exceed 1.5 parts per million in boiler feed water. Copolymer contains not more than 0.5...

  19. Learning Integer Addition: Is Later Better?

    ERIC Educational Resources Information Center

    Aqazade, Mahtob; Bofferding, Laura; Farmer, Sherri

    2017-01-01

    We investigate thirty-three second and fifth-grade students' solution strategies on integer addition problems before and after analyzing contrasting cases with integer addition and participating in a lesson on integers. The students took a pretest, participated in two small group sessions and a short lesson, and took a posttest. Even though the…

  20. Non-autoclaved aerated concrete with mineral additives

    NASA Astrophysics Data System (ADS)

    Il'ina, L. V.; Rakov, M. A.

    2016-01-01

    We investigated the effect of joint grinding of Portland cement clinker, silica and carbonate components and mineral additives to specific surface of 280 - 300 m2/kg on the properties (strength, average density and thermal conductivity) of non-autoclaved aerated concrete, and the porosity of the hardened cement paste produced from Portland cement clinker with mineral additives. The joint grinding of the Portland cement clinker with silica and carbonate components and mineral additives reduces the energy consumption of non-autoclaved aerated concrete production. The efficiency of mineral additives (diopside, wollastonite) is due to the closeness the composition, the type of chemical bonds, physical and chemical characteristics (specific enthalpy of formation, specific entropy) to anhydrous clinker minerals and their hydration products. Considering the influence of these additions on hydration of clinker minerals and formation of hardened cement paste structure, dispersed wollastonite and diopside should be used as mineral additives. The hardness and, consequently, the elastic modulus of diopside are higher than that of hardened cement paste. As a result, there is a redistribution of stresses in the hardened cement paste interporous partitions and hardening, both the partitions and aerated concrete on the whole. The mineral additives introduction allowed to obtain the non-autoclaved aerated concrete with average density 580 kg/m3, compressive strength of 3.3 MPa and thermal conductivity of 0.131 W/(m.°C).