Sample records for technetium-99m human serum

  1. Measurement of translymphatic fluid absorption using technetium-99m human serum albumin diethylenetriamine pentaacetic acid in continuous ambulatory peritoneal dialysis patients.

    PubMed

    Terawaki, Hiroyuki; Nakayama, Masaaki; Seto, Kazuhiko; Yoshimura, Kazunobu; Hasegawa, Toshio

    2004-08-01

    We have established a new method of measuring translymphatic fluid absorption (TLA) using technetium-99m ((99m)Tc) human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) that can be used commonly in clinical practice. This new method was applied in 13 continuous ambulatory peritoneal dialysis patients (11 males and two females) who had various peritoneal permeability and capacities for peritoneal transport of water. (99m)Tc-HSAD 740MBq was injected in 2 L of peritoneal dialysis fluid with 2.5% glucose, mixed well, and administered intraperitoneally. The fluid was drained extraperitoneally after 4 h and TLA was determined by the in vivo loss of (99m)Tc-HSAD. TLA was 1.41 +/- 1.11 mL/min (mean +/- SD; range, 0.27-3.69 mL/min). The estimated reduction rate by TLA in trans-peritoneally removed fluid ranged from 14.2 to 84.4%, indicating that TLA could have an extremely significant negative effect in some cases on total drainage volume. The present study, using new tracer (99m)Tc-HSAD, could confirm a large individual difference in TLA, indicating TLA as an important contributing factor for fluid-removal failure in continuous ambulatory peritoneal dialysis patients.

  2. Technetium-99m: basic nuclear physics and chemical properties.

    PubMed

    Castronovo, F P

    1975-05-01

    The nuclear physics and chemical properties of technetium-99m are reviewed. The review of basic nuclear physics includes: classification of nuclides, nuclear stability, production of radionuclides, artificial production of molybdenum-99, production of technetium 99m and -99Mo-99mTc generators. The discussion of the chemistry of technetium includes a profile of several -99mCc-labeled radiopharmaceuticals.

  3. Significance of Technetium-99m Human Serum Albumin Diethylenetriamine Pentaacetic Acid Scintigraphy in Patients with Nephrotic Syndrome

    PubMed Central

    Takashima, Tsuyoshi; Kishi, Tomoya; Onozawa, Koji; Rikitake, Shuichi; Miyazono, Motoaki; Otsuka, Takateru; Irie, Hiroyuki; Iwakiri, Ryuichi; Fujimoto, Kazuma; Ikeda, Yuji

    2015-01-01

    It is thought that a large amount of albumin leaking from the glomerulus in nephrotic syndrome (NS) is reabsorbed at the proximal tubule and catabolized. Therefore, it is possible the final quantity of urinary protein does not always reflect the amount of leakage of protein from the glomerulus. We experienced two cases without nephrotic range proteinuria thought to involve hypoproteinemia due to the same pathophysiology as NS. On these patients, we performed protein leakage scintigraphy with technetium-99m human serum albumin diethylenetriamine pentaacetic acid (99mTc-HSAD) to exclude a diagnosis of protein-losing gastroenteropathy and observed diffuse positive accumulation in the kidneys with more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration. In healthy adults intravenously given 99mTc-HSAD, the same dynamics are observed as in albumin metabolism, and the organ radioactivity of the liver and kidneys after 24 hours is equal. Therefore, we thought it was possible that the renal uptake 24 hours after 99mTc-HSAD administration was a characteristic finding of NS. In order to confirm it, the subjects were divided into two groups: the NS group (n = 10) and the non-NS group (n = 7). We defined more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration as Dense Kidney (+). Furthermore, we designed regions of interest in the right and left kidneys and liver on anterior and posterior images, then calculated the kidney-liver ratio. Nine of the ten patients had Dense Kidney (+) in the NS group, compared to none in the non-NS group. And the kidney-liver ratio was significantly higher in the NS group than in the non-NS group on each view in the bilateral kidneys. In conclusion, our results suggest that the renal uptake 24 hours after 99mTc-HSAD administration is a characteristic finding of NS. PMID:25859658

  4. Significance of technetium-99m human serum albumin diethylenetriamine pentaacetic acid scintigraphy in patients with nephrotic syndrome.

    PubMed

    Takashima, Tsuyoshi; Kishi, Tomoya; Onozawa, Koji; Rikitake, Shuichi; Miyazono, Motoaki; Otsuka, Takateru; Irie, Hiroyuki; Iwakiri, Ryuichi; Fujimoto, Kazuma; Ikeda, Yuji

    2015-01-01

    It is thought that a large amount of albumin leaking from the glomerulus in nephrotic syndrome (NS) is reabsorbed at the proximal tubule and catabolized. Therefore, it is possible the final quantity of urinary protein does not always reflect the amount of leakage of protein from the glomerulus. We experienced two cases without nephrotic range proteinuria thought to involve hypoproteinemia due to the same pathophysiology as NS. On these patients, we performed protein leakage scintigraphy with technetium-99m human serum albumin diethylenetriamine pentaacetic acid (99mTc-HSAD) to exclude a diagnosis of protein-losing gastroenteropathy and observed diffuse positive accumulation in the kidneys with more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration. In healthy adults intravenously given 99mTc-HSAD, the same dynamics are observed as in albumin metabolism, and the organ radioactivity of the liver and kidneys after 24 hours is equal. Therefore, we thought it was possible that the renal uptake 24 hours after 99mTc-HSAD administration was a characteristic finding of NS. In order to confirm it, the subjects were divided into two groups: the NS group (n = 10) and the non-NS group (n = 7). We defined more intense uptake in the kidney than the liver on the anterior view 24 hours after 99mTc-HSAD administration as Dense Kidney (+). Furthermore, we designed regions of interest in the right and left kidneys and liver on anterior and posterior images, then calculated the kidney-liver ratio. Nine of the ten patients had Dense Kidney (+) in the NS group, compared to none in the non-NS group. And the kidney-liver ratio was significantly higher in the NS group than in the non-NS group on each view in the bilateral kidneys. In conclusion, our results suggest that the renal uptake 24 hours after 99mTc-HSAD administration is a characteristic finding of NS.

  5. The use of technetium-99m-labeled human serum albumin diethylenetriamine pentaacetic acid single-photon emission CT scan in the follow-up of type II endoleak treatment.

    PubMed

    Nakai, Motoki; Sato, Hirotatsu; Ikoma, Akira; Sonomura, Tetsuo; Sato, Morio

    2014-03-01

    An 84-year-old woman presented with persistent type II endoleak with sac expansion from 57 mm to 75 mm during 4-year follow-up after endovascular abdominal aortic aneurysm repair. The patient underwent transabdominal embolization with coils and N-butyl cyanoacrylate/ethiodized oil (Lipiodol; Guerbet, Villepinte, France) mixture (2.5 mL). Because of the anticipated embolization artifacts on follow-up computed tomography (CT), technetium-99m-labeled human serum albumin diethylenetriamine pentaacetic acid single-photon emission computed tomography ((99m)Tc-HSAD SPECT) was performed before and after the intervention. Perigraft accumulation on (99m)Tc-HSAD SPECT corresponding to the endoleak disappeared after embolization. CT scan performed 12 months after embolization showed no signs of sac expansion. (99m)Tc-HSAD SPECT may be useful for evaluating therapeutic effect after embolization for endoleak. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  6. 99M-Technetium labeled tin colloid radiopharmaceuticals

    DOEpatents

    Winchell, Harry S.; Barak, Morton; Van Fleet, III, Parmer

    1976-07-06

    An improved 99m-technetium labeled tin(II) colloid, size-stabilized for reticuloendothelial organ imaging without the use of macromolecular stabilizers and a packaged tin base reagent and an improved method for making it are disclosed.

  7. Radionuclide Basics: Technetium-99

    EPA Pesticide Factsheets

    Technetium-99 (chemical symbol Tc-99) is a silver-gray, radioactive metal. It occurs naturally in very small amounts in the earth's crust, but is primarily man-made. Technetium-99m is a short-lived form of Tc-99 that is used as a medical diagnostic tool.

  8. Transglutaminase-mediated conjugation and nitride-technetium-99m labelling of a bis(thiosemicarbazone) bifunctional chelator.

    PubMed

    Salvarese, Nicola; Spolaore, Barbara; Marangoni, Selena; Pasin, Anna; Galenda, Alessandro; Tamburini, Sergio; Cicoria, Gianfranco; Refosco, Fiorenzo; Bolzati, Cristina

    2018-06-01

    An assessment study involving the use of the transglutaminase (TGase) conjugation method and the nitride-technetium-99m labelling on a bis(thiosemicarbazone) (BTS) bifunctional chelating agent is presented. The previously described chelator diacetyl-2-(N 4 -methyl-3-thiosemicarbazone)-3-(N 4 -amino-3-thiosemicarbazone), H 2 ATSM/A, has been functionalized with 6-aminohexanoic acid (ε-Ahx) to generate the bifunctional chelating agent diacetyl-2-(N 4 -methyl-3-thiosemicarbazone)-3-[N 4 -(amino)-(6-aminohexanoic acid)-3-thiosemicarbazone], H 2 ATSM/A-ε-Ahx (1), suitable for conjugation to glutamine (Gln) residues of bioactive molecules via TGase. The feasibility of the TGase reaction in the synthesis of a bioconjugate derivative was investigated using Substance P (SP) as model peptide. Compounds 1 and H 2 ATSM/A-ε-Ahx-SP (2) were labelled with nitride-technetium-99m, obtaining the complexes [ 99m Tc][Tc(N)(ATSM/A-ε-Ahx)] ( 99m Tc1) and [ 99m Tc][Tc(N)(ATSM/A-ε-Ahx-SP)] ( 99m Tc2). The chemical identity of 99m Tc1 and 99m Tc2 was confirmed by radio/UV-RP-HPLC combined with ESI-MS analysis on the respective carrier-added products 99g/99m Tc1 and 99g/99m Tc2. The stability of the radiolabelled complexes after incubation in various environments was investigated. All the results were compared with those obtained for the corresponding 64 Cu-analogues, 64 Cu1 and 64 Cu2. The TGase reaction allows the conjugation of 1 with the peptide, but it is not highly efficient due to instability of the chelator in the required conditions. The SP-conjugated complexes are unstable in mouse and human sera. However, indeed the BTS system can be exploited as nitride-technetium-99m chelator for highly efficient technetium labelling, thus making compound 1 worthy of further investigations for new targeted technetium and copper radiopharmaceuticals encompassing Single Photon Emission Computed Tomography and Positron Emission Tomography imaging. Copyright © 2018 Elsevier Inc. All rights

  9. 99M-technetium labeled macroaggregated human serum albumin pharmaceutical

    DOEpatents

    Winchell, Harry S.; Barak, Morton; Van Fleet, III, Parmer

    1977-05-17

    A reagent comprising macroaggregated human serum albumin having dispersed therein particles of stannous tin and a method for instantly making a labeled pharmaceutical therefrom, are disclosed. The labeled pharmaceutical is utilized in organ imaging.

  10. Human Fibronectin Extra-Domain B (EDB)-Specific Aptide (APTEDB) Radiolabelling with Technetium-99m as a Potent Targeted Tumour-Imaging Agent.

    PubMed

    Mohammadgholi, Mohsen; Sadeghzadeh, Nourollah; Erfani, Mostafa; Abediankenari, Saeid; Abedi, Seyed Mohammad; Emrarian, Iman; Jafari, Narjes; Behzadi, Ramezan

    2018-01-01

    Human fibronectin extra-domain B (EDB) is particularly expressed during angiogenesis progression. It is, thus, a promising marker of tumour growth. Aptides are a novel class of peptides with high-affinity binding to specific protein targets. APTEDB is an antagonist-like ligand that especially interacts with human fibronectin EDB. This study was the first attempt in which the hydrazinonicotinamide (HYNIC)-conjugated APTEDB was labelled with technetium-99m (99mTc) as an appropriate radiotracer and tricine/EDDA exchange labeling. Radiochemical purity, normal saline, and serum stability were evaluated by HPLC and radio-isotope TLC scanner. Other examinations, such as protein-binding calculation, dissociation radioligand binding assay, and partition coefficient constant determination, were also carried out. The cellular-specific binding of 99mTc- HYNIC-conjugated APTEDB was assessed in two EDB-positive (U87MG) and EDB-negative (U373MG) cell lines. Bio-distribution was investigated in normal mice as well as in U87MG and U373MG tumour-bearing mice. Eventually, the radiolabelled APTEDB was used for tumour imaging using planar SPECT. Radiolabelling was achieved with high purity (up to 97%) and accompanied by high solution (over 90% after overnight) and serum (80% after 2 hours) stability. The obtained cellular-specific binding ratio was greater than nine-fold. In-vivo experiments showed rapid blood clearance with mainly renal excretion and tumour uptake specificity (0.48±0.03% ID/g after 1h). The results of the imaging also confirmed considerable tumour uptake for EDB-positive cell line compared with the EDB-negative one. Aptides are considered to be a potent candidate for biopharmaceutical applications. They can be modified with imaging or therapeutic agents. This report shows the capability of 99mTc-HYNIC-APTEDB for human EDB-expressing tumours detection. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  11. Effects of concurrent drug therapy on technetium /sup 99m/Tc gluceptate biodistribution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hinkle, G.H.; Basmadjian, G.P.; Peek, C.

    Drug interactions with /sup 99m/Tc gluceptate resulting in altered biodistribution were studied using chart review and animal tests. Charts of nine patients who had abnormal gallbladder uptake of technetium /sup 99m/Tc gluceptate during a two-year period were reviewed to obtain data such as concurrent drug therapy, primary diagnosis, and laboratory values. Adult New Zealand white rabbits were then used for testing the biodistribution of technetium /sup 99m/Tc gluceptate when administered concurrently with possibly interacting drugs identified in the chart review--penicillamine, penicillin G potassium, penicillin V potassium, acetaminophen, and trimethoprim-sulfamethoxazole. Chart review revealed no conclusive patterns of altered biodistribution associated withmore » other factors. The data did suggest the possibility that the five drugs listed above might cause increased hepatobiliary clearance of the radiopharmaceutical. Animal tests showed that i.v. penicillamine caused substantial distribution of radioactivity into the gallbladder and small bowel. Minimally increased gallbladder radioactivity occurred when oral acetaminophen and trimethoprim-sulfamethoxazole were administered concurrently. Oral and i.v. penicillins did not increase gallbladder activity. Penicillamine may cause substantial alteration of the biodistribution of technetium /sup 99m/Tc gluceptate.« less

  12. Radioactive excretion in human milk following administration of /sup 99m/Tc macroaggregated albumin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pittard, W.B.; Merkatz, R.; Fletcher, B.D.

    Albumin-tagged sodium pertechnetate (technetium) is routinely used in nuclear medicine for scanning procedures of the lung. The rate of excretion of this radionuclide into breast milk and the resultant potential radiation hazard to the nursing infant have received little attention. Therefore the milk from a nursing mother who required a lung scan because of suspected pulmonary emboli using an intravenous injection of 4 mCi of /sup 99m/Tc macroaggregated human serum albumin was monitored. Albumin tagging severely limited the entrance of technetium into her milk and the radioactivity of the milk returned to base line by 24 hours. A total ofmore » 2.02 muCi of technetium was measured in the 24-hour milk collection after technetium injection and 94% of this amount was excreted by 15.5 hours. This amount of technetium administered orally to a newborn would deliver a total body radiation dose of .3 mrad. Therefore, an infant would receive trivial doses of radiation if breast-feeding were resumed 15.5 hours after administration of the radionuclide to the mother and nursing can clearly be resumed safely 24 hours after injection.« less

  13. Accelerator Generation and Thermal Separation (AGATS) of Technetium-99m

    ScienceCinema

    Grover, Blaine

    2018-05-01

    Accelerator Generation and Thermal Separation (AGATS) of Technetium-99m is a linear electron accelerator-based technology for producing medical imaging radioisotopes from a separation process that heats, vaporizes and condenses the desired radioisotope. You can learn more about INL's education programs at http://www.facebook.com/idahonationallaboratory.

  14. Soft-tissue sarcoma: imaged with technetium-99m pyrophosphate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Blatt, C.J.; Hayt, D.B.; Desai, M.

    1977-11-01

    A liposarcoma showed intense concentration of technetium-99m pyrophosphate. An angiogram demonstrated a highly vascular lesion, and it is suggested that blood flow played a major role in allowing the tumor to be demonstrated on scintiphotography. There was some histologic evidence of calcification which probably also contributed to bone-tracer disposition. Quantitative analysis of the specimen demonstrated that this calcification was located primarily in the areas of hemorrhage and necrosis.

  15. Hyperthermia increases accumulation of technetium-99m-labeled liposomes in feline sarcomas.

    PubMed

    Matteucci, M L; Anyarambhatla, G; Rosner, G; Azuma, C; Fisher, P E; Dewhirst, M W; Needham, D; Thrall, D E

    2000-09-01

    The effect of hyperthermia on the accumulation of technetium-99m-labeled liposomes was studied in feline sarcomas. Each cat received two separate injections of liposomes. The first was used to quantify the amount of technetium-99m-labeled liposomes within the tumor under normothermic conditions. The second injection was made at the beginning of a 60-min hyperthermia procedure. Planar scintigraphy was used to measure the activity of technetium-99m-labeled liposomes within the tumor at predetermined times up to 18 h after injection. Regions of interest were drawn for the tumor, lungs, liver, kidney, and aorta. Counts in the regions of interest were decay corrected. Counts/pixel in the tumor under normothermic and hyperthermic conditions were normalized to aorta counts/pixel. A total of 16 cats were eligible for the study. In two of the 16 cats, incomplete count data precluded analysis. In the remaining 14 cats, hyperthermia resulted in a significant increase in liposome accumulation in the tumor (P = 0.001). Tumor volume ranged from 1.2 to 236.2 cm3, and thermal dose ranged from 2.0 to 243.3 CEM43CT90 (equivalent time that the 10th percentile temperature was equal to 43 degrees C). There was not a relationship between either tumor volume or hyperthermia dose on the magnitude of increased liposome accumulation, suggesting that this method has application across a range of tumor volumes and degrees of heatibility.

  16. Technetium-99m-labeled annexin V imaging for detecting prosthetic joint infection in a rabbit model.

    PubMed

    Tang, Cheng; Wang, Feng; Hou, Yanjie; Lu, Shanshan; Tian, Wei; Xu, Yan; Jin, Chengzhe; Wang, Liming

    2015-05-01

    Accurate and timely diagnosis of prosthetic joint infection is essential to initiate early treatment and achieve a favorable outcome. In this study, we used a rabbit model to assess the feasibility of technetium-99m-labeled annexin V for detecting prosthetic joint infection. Right knee arthroplasty was performed on 24 New Zealand rabbits. After surgery, methicillin-susceptible Staphylococcus aureus was intra-articularly injected to create a model of prosthetic joint infection (the infected group, n = 12). Rabbits in the control group were injected with sterile saline (n = 12). Seven and 21 days after surgery, technetium-99m-labeled annexin V imaging was performed in 6 rabbits of each group. Images were acquired 1 and 4 hours after injection of technetium-99m-labeled annexin V (150 MBq). The operated-to-normal-knee activity ratios were calculated for quantitative analysis. Seven days after surgery, increased technetium-99m-labeled annexin V uptake was observed in all cases. However, at 21 days a notable decrease was found in the control group, but not in the infected group. The operated-to-normal-knee activity ratios of the infected group were 1.84 ± 0.29 in the early phase and 2.19 ± 0.34 in the delay phase, both of which were significantly higher than those of the control group (P = 0.03 and P = 0.02). The receiver operator characteristic curve analysis showed that the operated-to-normal-knee activity ratios of the delay phase at 21 days was the best indicator, with an accuracy of 80%. In conclusion, technetium-99m-labeled annexin V imaging could effectively distinguish an infected prosthetic joint from an uninfected prosthetic joint in a rabbit model.

  17. Technetium-99m NGA functional hepatic imaging: preliminary clinical experience

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Stadalnik, R.C.; Vera, D.R.; Woodle, E.S.

    1985-11-01

    Technetium-99m galactosyl-neoglycoalbumin ( (Tc)NGA) is a radiolabeled ligand to hepatic binding protein, a receptor which resides at the plasma membrane of hepatocytes. This receptor-binding radiopharmaceutical and its kinetic model provide a noninvasive method for the assessment of liver function. Eighteen patients were studied: seven with hepatoma, eight with liver metastases, four with cirrhosis, and one patient with acute fulminant non-A, non-B hepatitis. Technetium-99m NGA liver imaging provided anatomic information of diagnostic quality comparable to that obtained with other routine imaging modalities, including computed tomography, angiography, ultrasound, and (Tc)sulfur colloid scintigraphy. Kinetic modeling of dynamic (Tc)NGA data produced estimates of standardizedmore » hepatic blood flow, Q (hepatic blood flow divided by total blood volume), and hepatic binding protein concentration, (HBP). Significant rank correlation was obtained between (HBP) estimates and CTC scores. This correlation supports the hypothesis that (HBP) is a measure of functional hepatocyte mass. The combination of decreased Q and markedly reduced (HBP) may have prognostic significance; all three patients with this combination died of hepatic failure within 6 wk of imaging.« less

  18. Technetium-99m-labeled rituximab for use as a specific tracer of sentinel lymph node biopsy: a translational research study.

    PubMed

    Wang, Xuejuan; Yang, Zhi; Lin, Baohe; Zhang, Yan; Zhai, Shizhen; Zhao, Qichao; Xie, Qing; Liu, Fei; Han, Xuedi; Li, Jinfeng; Ouyang, Tao

    2016-06-21

    We aimed to develop and translate a CD20-antigen-targeted radiopharmaceutical, Technetium-99 m-labeled (99mTc) rituximab, for sentinel lymph node (SLN) detection. 99mTc-rituximab was synthesized and tested for stability in human serum. The binding affinity to CD20 was evaluated in Raji cells by flow cytometric analysis. Biodistribution and sentinel node mapping were carried out in bal b/c mice. Eighty-five patients with breast cancer participated in this study. Dynamic sentinel lymphoscintigraphy was first assessed in 12 patients before planar lymphoscintigraphy was assessed in a larger cohort. All patients underwent sentinel lymph node biopsy (SLNB), followed by axillary lymph node dissection. The cell-binding study showed that 99mTc-rituximab possessed compatible affinity to human CD20. In the mechanism study, 99mTc-labeled anti-mouse CD20 monoclonal antibodies could bind to mouse CD20 and accumulate in the SLN with 2.62±1.25 % of the percentage of injected activity, which could be blocked by excessive unlabeled antibody. Low uptake of non-sentinel nodes and fast clearance from the injection site were observed in the mice. Sentinel nodes were identified in 82 of 85 breast cancer patients (96.5%) by lymphoscintigraphy and SLNB. The sensitivity, specificity, and accuracy were 96.8% (30/31), 100% (51/51), and 98.8% (81/82), respectively. 99mTc-rituximab, specifically binding to CD20, met most of the requirements of an ideal sentinel mapping agent for use in clinical settings.

  19. Sensitivity of technetium-99m-pyrophosphate scintigraphy in diagnosing cardiac amyloidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Falk, R.H.; Lee, V.W.; Rubinow, A.

    1983-03-01

    To determine the value of technetium-99m-pyrophosphate myocardial scintigraphy in the diagnosis of amyloid heart disease this procedure was prospectively performed in 20 consecutive patients with biopsy-proven primary amyloidosis. Eleven patients had echocardiographic abnormalities compatible with amyloid cardiomyopathy, 9 of whom had congestive heart failure. Diffuse myocardial pyrophosphate uptake was of equal or greater intensity than that of the ribs in 9 of the 11 patients with echocardiograms suggestive of amyloidosis, but in only 2 of the 9 with normal echocardiograms, despite abnormal electrocardiograms (p less than 0.01). Increased wall thickness measured by M-mode echocardiography correlated with myocardial pyrophosphate uptake (rmore » . 0.68, p less than 0.01). None of 10 control patients with nonamyloid, nonischemic heart disease had a strongly positive myocardial pyrophosphate uptake. Thus, myocardial technetium-99m-pyrophosphate scanning is a sensitive and specific test for the diagnosis of cardiac amyloidosis in patients with congestive heart failure of obscure origin. It does not appear to be of value for the early detection of cardiac involvement in patients with known primary amyloidosis without echocardiographic abnormalities.« less

  20. Periarticular uptake of /sup 99m/technetium diphosphonate in psoriatics. Correlation with cutaneous activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Namey, T.C.; Rosenthall, L.

    1976-01-01

    The periarticular uptake of /sup 99m/technetium-labeled diphosphonate (/sup 99m/TcDP) was compared in 12 patients hospitalized for psoriasis and in 12 hospitalized for other dermatoses not associated with arthropathy. The 12 patients with psoriasis had recent onset disease of less than 5 years duration; neither group had historical or clinical evidence of arthritis. All psoriatics had markedly abnormal scans with symmetrically increased periarticular uptake about the imaged joints. None of the controls had similar findings. In 4 patients scanned with /sup 99m/technetium-pertechnetate within 24 hours of their /sup 99m/TcDP scan, no evidence of inflammatory synovitis was found. Three of these patientsmore » were serially imaged with /sup 99m/TcDP at intervals of 2 weeks to 3 months after their initial study, when obvious clinical improvement in their psoriasis was apparent. Improvement in the radionuclide joint images was demonstrated in some of the patients, but none reverted to normal during the study period. In light of recent evidence for the preferential binding of /sup 99m/TcDP to immature collagen, it is suggested that psoriasis may represent a generalized, but uncharacterized, collagen disorder present in bone as well as skin, linking the cutaneous disease with the potential for arthropathy.« less

  1. A biokinetic model for systemic technetium in adult humans

    DOE PAGES

    Leggett, Richard Wayne; Giussani, Augusto

    2015-04-10

    The International Commission on Radiological Protection (ICRP) currently is updating its biokinetic and dosimetric models for internally deposited radionuclides. Technetium (Tc), the lightest element that exists only in radioactive form, has two important isotopes from the standpoint of potential risk to humans: the long-lived isotope 99Tm(T 1/2=2.1x10 5 y) is present in high concentration in nuclear waste, and the short-lived isotope 99mTc (T 1/2=6.02 h) is the most commonly used radionuclide in diagnostic nuclear medicine. This paper reviews data on the biological behavior of technetium and proposes a biokinetic model for systemic technetium in the adult human body formore » use in radiation protection. Compared with the ICRP s current occupational model for systemic technetium, the proposed model provides a more realistic description of the paths of movement of technetium in the body; provides greater consistency with experimental and medical data; and, for most radiosensitive organs, yields substantially different estimates of cumulative activity (total radioactive decays within the organ) following uptake of 99Tm or 99mTc to blood.« less

  2. A solvent-extraction module for cyclotron production of high-purity technetium-99m.

    PubMed

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Uccelli, Licia; Pasquali, Micòl; Duatti, Adriano; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Esposito, Juan

    2016-12-01

    The design and fabrication of a fully-automated, remotely controlled module for the extraction and purification of technetium-99m (Tc-99m), produced by proton bombardment of enriched Mo-100 molybdenum metallic targets in a low-energy medical cyclotron, is here described. After dissolution of the irradiated solid target in hydrogen peroxide, Tc-99m was obtained under the chemical form of 99m TcO 4 - , in high radionuclidic and radiochemical purity, by solvent extraction with methyl ethyl ketone (MEK). The extraction process was accomplished inside a glass column-shaped vial especially designed to allow for an easy automation of the whole procedure. Recovery yields were always >90% of the loaded activity. The final pertechnetate saline solution Na 99m TcO 4 , purified using the automated module here described, is within the Pharmacopoeia quality control parameters and is therefore a valid alternative to generator-produced 99m Tc. The resulting automated module is cost-effective and easily replicable for in-house production of high-purity Tc-99m by cyclotrons. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Technetium-99m production issues in the United Kingdom.

    PubMed

    Green, Christopher H

    2012-04-01

    Nuclear Medicine developed when it was realised that a radioisotopic substitution of Iodine-131 for the stable Iodine-127 would follow the same metabolic pathway in the body enabling the thyroid to be imaged and the thyroid uptake measured. The Iodine could be complexed with pharmaceutical substrates to enable other organs to be imaged, but its use was limited and high gamma energy and beta emission restricted the activity of each radiopharmaceutical used, leading to long acquisition times and degraded images. As a pure gamma emitter of 140 keV and with a 6-h half-life, Technetium-99m is a better radionuclide and images a wider range of bodily organs. However, its short half-life also requires it to be eluted from its mother radionuclide, Mo-99, in a generator, delivered weekly from radiopharmaceutical companies who obtain the Mo-99 in liquid form from high-flux research reactors. All went well till around 2007, when the NRU Reactor in Canada was closed and all other reactors went down for various periods for unrelated problems, leading to widespread Mo-99 shortages. Although the reactors have since recovered, they are 48 to 57 years old, and it seems that few governments have made any future provision such as building replacement reactors.

  4. Technetium-99m production issues in the United Kingdom

    PubMed Central

    Green, Christopher H.

    2012-01-01

    Nuclear Medicine developed when it was realised that a radioisotopic substitution of Iodine-131 for the stable Iodine-127 would follow the same metabolic pathway in the body enabling the thyroid to be imaged and the thyroid uptake measured. The Iodine could be complexed with pharmaceutical substrates to enable other organs to be imaged, but its use was limited and high gamma energy and beta emission restricted the activity of each radiopharmaceutical used, leading to long acquisition times and degraded images. As a pure gamma emitter of 140 keV and with a 6-h half-life, Technetium-99m is a better radionuclide and images a wider range of bodily organs. However, its short half-life also requires it to be eluted from its mother radionuclide, Mo-99, in a generator, delivered weekly from radiopharmaceutical companies who obtain the Mo-99 in liquid form from high-flux research reactors. All went well till around 2007, when the NRU Reactor in Canada was closed and all other reactors went down for various periods for unrelated problems, leading to widespread Mo-99 shortages. Although the reactors have since recovered, they are 48 to 57 years old, and it seems that few governments have made any future provision such as building replacement reactors. PMID:22557795

  5. Technetium-99m generator system

    DOEpatents

    Mirzadeh, Saed; Knapp, Jr., Furn F.; Collins, Emory D.

    1998-01-01

    A .sup.99 Mo/.sup.99m Tc generator system includes a sorbent column loaded with a composition containing .sup.99 Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating .sup.99m Tc eluted from the sorbent column. A method of preparing a concentrated solution of .sup.99m Tc includes the general steps of: a. providing a sorbent column loaded with a composition containing .sup.99 Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; b. eluting the sorbent column with a salt solution to elute .sup.99m Tc from the sorbent and to trap and concentrate the eluted .sup.99m Tc on the ion-exchange column; and c. eluting the concentrated .sup.99m Tc from the ion-exchange column with a solution comprising a reductive complexing agent.

  6. Technetium-99m generator system

    DOEpatents

    Mirzadeh, S.; Knapp, F.F. Jr.; Collins, E.D.

    1998-06-30

    A {sup 99}Mo/{sup 99m}Tc generator system includes a sorbent column loaded with a composition containing {sup 99}Mo. The sorbent column has an effluent end in fluid communication with an anion-exchange column for concentrating {sup 99m}Tc eluted from the sorbent column. A method of preparing a concentrated solution of {sup 99m}Tc includes the general steps of: (a) providing a sorbent column loaded with a composition containing {sup 99}Mo, the sorbent column having an effluent end in fluid communication with an anion-exchange column; (b) eluting the sorbent column with a salt solution to elute {sup 99m}Tc from the sorbent and to trap and concentrate the eluted {sup 99m}Tc on the ion-exchange column; and (c) eluting the concentrated {sup 99m}Tc from the ion-exchange column with a solution comprising a reductive complexing agent. 1 fig.

  7. Images of liposarcoma using technetium-99m bleomycin and technetium (V)-99m DMSA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ohta, H.; Shane, F.I.; Endo, K.

    1986-12-01

    The effectiveness of Tc-99m bleomycin (BLM) and Tc(V)-99m DMSA are compared with that of Ga-67 citrate, which is currently the most widely used agent. In four patients with lipomatous tumors, the clinical significance of tumor imaging with each of these three agents is discussed and compared. Results indicate that both Tc-99m BLM and Tc(V)-99m DMSA are superior in detecting the extension or localization of liposarcomas.

  8. Guava extract (Psidium guajava) alters the labelling of blood constituents with technetium-99m.

    PubMed

    Abreu, P R C; Almeida, M C; Bernardo, R M; Bernardo, L C; Brito, L C; Garcia, E A C; Fonseca, A S; Bernardo-Filho, M

    2006-06-01

    Psidium guajava (guava) leaf is a phytotherapic used in folk medicine to treat gastrointestinal and respiratory disturbances and is used as anti-inflammatory medicine. In nuclear medicine, blood constituents (BC) are labelled with technetium-99m ((99m)Tc) and used to image procedures. However, data have demonstrated that synthetic or natural drugs could modify the labelling of BC with (99m)Tc. The aim of this work was to evaluate the effects of aqueous extract of guava leaves on the labelling of BC with (99m)Tc. Blood samples of Wistar rats were incubated with different concentrations of guava extract and labelled with (99m)Tc after the percentage of incorporated radioactivity (%ATI) in BC was determined. The results suggest that aqueous guava extract could present antioxidant action and/or alters the membrane structures involved in ion transport into cells, thus decreasing the radiolabelling of BC with (99m)Tc. The data showed significant (P<0.05) alteration of ATI in BC from blood incubated with guava extract.

  9. Guava extract (Psidium guajava) alters the labelling of blood constituents with technetium-99m*

    PubMed Central

    Abreu, P.R.C.; Almeida, M.C.; Bernardo, R.M.; Bernardo, L.C.; Brito, L.C.; Garcia, E.A.C.; Fonseca, A.S.; Bernardo-Filho, M.

    2006-01-01

    Psidium guajava (guava) leaf is a phytotherapic used in folk medicine to treat gastrointestinal and respiratory disturbances and is used as anti-inflammatory medicine. In nuclear medicine, blood constituents (BC) are labelled with technetium-99m (99mTc) and used to image procedures. However, data have demonstrated that synthetic or natural drugs could modify the labelling of BC with 99mTc. The aim of this work was to evaluate the effects of aqueous extract of guava leaves on the labelling of BC with 99mTc. Blood samples of Wistar rats were incubated with different concentrations of guava extract and labelled with 99mTc after the percentage of incorporated radioactivity (%ATI) in BC was determined. The results suggest that aqueous guava extract could present antioxidant action and/or alters the membrane structures involved in ion transport into cells, thus decreasing the radiolabelling of BC with 99mTc. The data showed significant (P<0.05) alteration of ATI in BC from blood incubated with guava extract. PMID:16691636

  10. Identification of Warthin tumor: magnetic resonance imaging versus salivary scintigraphy with technetium-99m pertechnetate.

    PubMed

    Motoori, Ken; Ueda, Takuya; Uchida, Yoshitaka; Chazono, Hideaki; Suzuki, Homare; Ito, Hisao

    2005-01-01

    The aim of this study was to evaluate the accuracy of technetium-99m (Tc-99m) pertechnetate scintigraphy and magnetic resonance (MR) imaging in the diagnosis of Warthin tumor. Sixteen cases of Warthin tumor and 17 cases of non-Warthin tumor were examined by Tc-99m pertechnetate scintigraphy with lemon juice stimulation and MR imaging, including T1-weighted, T2-weighted, short inversion time inversion recovery, diffusion-weighted, and contrast-enhanced dynamic images. We used the receiver operating characteristic (ROC) curve to evaluate diagnostic accuracy. The mean area under the ROC curves of MR imaging in the diagnosis of Warthin tumor (0.97) was higher than that of Tc-99m pertechnetate scintigraphy (0.88). Magnetic resonance imaging is more useful in the evaluation of Warthin tumor than Tc-99m pertechnetate scintigraphy.

  11. Lung ventilation studies with technetium-99m Pseudogas

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burch, W.M.; Sullivan, P.J.; Lomas, F.E.

    1986-06-01

    Technetium-99m Pseudogas is an ultrafine near monodisperse aerosol of 0.12-microgram diam particle size. This report describes initial clinical experiences with 27 patients referred for investigation of suspected pulmonary embolism, and in whom Pseudogas ventilation images were compared with a high quality commercial aerosol. An additional group of ten patients with severe COPD was examined in a comparative trial of Pseudogas with 81mKr. Pseudogas was better than a conventional aerosol in reaching a diagnosis of pulmonary embolism using a simple blinded comparison with coded images. In addition, bronchial deposition was minimal unless COPD was severe. Moderately well patients had no difficultymore » inhaling the necessary activity in one or two breaths, and even severely ill and frail aged persons could accomplish the passive breathing maneuver in less than a minute. Clearance of Pseudogas was directly to the systemic circulation with a half-time of 10 min in normal subjects extending up to 100 min in patients with airways disease.« less

  12. Imaging experimental intraabdominal abscesses with 99mTc-PEG liposomes and 99mTc-HYNIC IgG.

    PubMed Central

    Dams, E T; Reijnen, M M; Oyen, W J; Boerman, O C; Laverman, P; Storm, G; van der Meer, J W; Corstens, F H; van Goor, H

    1999-01-01

    OBJECTIVE: To evaluate the accuracy of technetium-99m-labeled polyethylene glycol-coated liposomes (99mTc-PEG liposomes) and technetium-99m-labeled nonspecific human immunoglobulin G (99mTc-HYNIC IgG) for the scintigraphic detection of experimental intraabdominal abscesses in comparison with that of a standard agent, gallium-67 citrate. BACKGROUND: Scintigraphic imaging techniques can be very useful for the rapid and accurate localization of intraabdominal abscesses. Two newly developed radiolabeled agents, 99mTc-PEG liposomes and 99mTc-HYNIC IgG, have shown to be excellent agents for imaging experimental focal infection, but have not yet been studied in the detection of abdominal abscesses. METHODS: Intraabdominal abscesses were induced in 42 rats using the cecal ligation and puncture technique. Seven days later, randomized groups of rats received 99mTc-PEG liposomes, 99mTc-HYNIC IgG, or 67Ga citrate intravenously. The rats were imaged up to 24 hours after the injection. The biodistribution of the radiolabel was determined by counting dissected tissues ex vivo. Macroscopic intraabdominal abnormalities and focal uptake on the images were independently scored on a semiquantitative scale. RESULTS: 99mTc-PEG liposomes provided the earliest scintigraphic visualization of the abscess (as soon as 2 hours after the injection vs. 4 hours for the other two agents). Liposomes, IgG, and gallium all showed similarly high absolute uptake in the abscess. Focal uptake of liposomes and gallium correlated best with the extent of the macroscopic abnormalities. CONCLUSIONS: 99mTc-PEG liposomes and 99mTc-HYNIC IgG performed at least as well as the standard agent, 67Ga citrate, in the detection of experimental intraabdominal abscesses, with obvious advantages such as lower radiation exposure and more favorable physical properties. Of the two technetium agents, the liposomes seemed to be superior, providing the earliest diagnostic image and the best correlation with the inflammatory

  13. The value and throughput of rest Thallium-201/stress Technetium -99m sestamibi dual-isotope myocardial SPECT.

    PubMed

    Okudan, Berna; Smitherman, Thomas C

    2004-06-01

    Myocardial perfusion scintigraphy is an established method in cardiology for the diagnosis and evaluation of coronary artery disease (CAD). Thallium-201 and Tc-99m sestamibi myocardial perfusion imaging has been widely accepted as non-invasive diagnostic procedure for detection of CAD, risk stratification and myocardial viability assessment. But, standard Tl-201 redistribution and same day or 2-day rest/stress Tc-99m sestamibi protocols are time-consuming. Hence, the dual isotope rest thallium-201/stress technetium-99m sestamibi gated single-photon emission tomography protocol has gained increasing popularity for these applications. Combining the use of thallium-201 with technetium-99m agents permits optimal image resolution and simultaneous assessment of viability. Dual-isotope imaging may be separate or simultaneous acquisition set-up. The more rapid completion of these studies is appreciated as an advantage by patients, technologists, interpreting and referring physicians, nurses and hospital management. Simultaneous imaging has the potential advantages of precise pixel registration and artifacts, if present, are identical in both thallium and sestamibi, and require only one set of imaging. Also, there are some disadvantages of spillover of activity from the Tc-99m to the Tl-201 window. Fortunately, despite this problem it can be overcome. Separate acquisition dual isotope also has some disadvantages. Difference in defect resolution in attenuation and scatter between T-201 and Tc-99m sestamibi potentially results in interpretation problems. But, studies about cost-effectiveness of dual isotope imaging showed that some selective elimination of the rest studies may decrease the cost of the nuclear procedures and should be considered in the current care health system.

  14. Technetium-99m mercaptoacetyltriglycine clearance: reference values for infants and children.

    PubMed

    Schofer, O; König, G; Bartels, U; Bockisch, A; Piepenburg, R; Beetz, R; Meyer, G; Hahn, K

    1995-11-01

    Six hundred and thirty-nine clearance studies performed in children aged 7 days to 19 years utilizing technetium-99m mercaptoacetyltriglycine (MAG 3) were retrospectively analysed. Standardized conditions for the investigation included: parenteral hydration (60 ml/hxm2 body surface) in addition to normal oral fluid intake, weight-related dose of 99mTc-MAG 3 (1 MBq/kg body weight, minimum 15 MBq) and calculation of clearance according to Bubeck et al. Of the 513 children, 169 included in this analysis could be classified as "normal" with regard to their renal function. Normal kidney function was judged by the following criteria: normal GFR for age, normal tubular function (absence of proteinuria and glucosuria), normal renal parenchyma (on ultrasonography, MAG 3 scan and intravenous pyelography), absence of significant obstruction and gross reflux (>grade I), no single kidney and no difference in split renal function >20%. Results showed increasing MAG 3 clearance values for infants during the first months of life, reaching the normal range for older children and adults between 7 and 12 months.

  15. Technetium-99m-labeled ceftizoxime loaded long-circulating and pH-sensitive liposomes used to identify osteomyelitis.

    PubMed

    Ferreira, Soraya Maria Zandim Maciel Dias; Domingos, Giselle Pires; Ferreira, Diego dos Santos; Rocha, Talita Guieiro Ribeiro; Serakides, Rogéria; de Faria Rezende, Cleuza Maria; Cardoso, Valbert Nascimento; Fernandes, Simone Odília Antunes; Oliveira, Mônica Cristina

    2012-07-15

    Osteomyelitis is an infectious disease located in the bone or bone marrow. Long-circulating and pH-sensitive liposomes containing a technetium-99m-labeled antibiotic, ceftizoxime, (SpHL-(99m)Tc-CF) were developed to identify osteomyelitis foci. Biodistribution studies and scintigraphic images of bone infection or non infection-bearing rats that had been treated with these liposomes were performed. A high accumulation in infectious foci and high values in the target-non target ratio could be observed. These results indicate the potential of SpHL-(99m)Tc-CF as a potential agent for the diagnosis of bone infections. Copyright © 2012 Elsevier Ltd. All rights reserved.

  16. Applicability of 99m Tc-Labeled Human Serum Albumin Scintigraphy in Dogs With Protein-Losing Enteropathy.

    PubMed

    Engelmann, N; Ondreka, N; von Pückler, K; Mohrs, S; Sicken, J; Neiger, R

    2017-03-01

    Diagnosis of protein loss into the gastrointestinal tract using noninvasive techniques is challenging. In people, scintigraphy not only is a sensitive tool to confirm protein-losing enteropathy (PLE), but it also allows for localization of protein loss. To investigate the feasibility of 99m Tc-labeled human serum albumin (HSA) scintigraphy in dogs with PLE in comparison with control dogs. A total of 8 clinically healthy control research dogs and 7 client-owned dogs with gastrointestinal clinical signs and hypoalbuminemia (serum albumin concentration <2.0 g/dL). Prospective case-control study. After IV injection of 400 MBq freshly prepared 99m Tc HSA (30 mg/dog), images of the abdomen were obtained 10, 60, 120, and 240 minutes postinjection. Additional images of the salivary and thyroid glands were obtained to rule out free 99m Tc. A scan was considered positive for PLE when radiopharmaceutical exudation was detectable in the intestinal tract. Only 1 control dog showed exudation of the radiopharmaceutical into the intestinal tract. No free 99m Tc was detected in any dog. In dogs with PLE, focal small intestinal and diffuse small intestinal radiopharmaceutical exudation into the bowel was detected in 2 and 3 dogs, respectively, whereas in 2 dogs, there was disagreement about whether radiopharmaceutical exudation was focal or diffuse. 99m Tc-labeled HSA scintigraphy was feasible to diagnose PLE in dogs. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  17. Evaluation of technetium-99m decay on Escherichia coli inactivation: effects of physical or chemical agents.

    PubMed Central

    Silva, C. R.; Valsa, J. O.; Caniné, M. S.; Caldeira-de-Araújo, A.; Bernardo-Filho, M.

    1998-01-01

    Technetium-99m (99mTc) has been used in nuclear medicine and in biomedical research to label molecular and cellular structures employed as radiotracers. Here, we have evaluated, on a DNA repair proficient Escherichia coli strain, the 99mTc decay inactivation and the influence of the (i) pre-treatment with metal ion chelators or of the (ii) treatment with a free radical scavenger on the protection of the cells against the lethal effect of the 99mTc. As SnCl2 is frequently used as a reducing agent in the 99mTc-labeling process, we have also studied the capability of SnCl2 to alter the biological effects induced by the 99mTc decay. As we are exposed to either chemical or physical agents in the nature, we have decided to study a possible influence of the ultraviolet solar radiation in the biological phenomena induced by the 99mTc decay. Our data point out (i) a very important role of the Auger and/or conversion electrons in the cytotoxicity induced by the 99mTc decay; (ii) SnCl2, the metal ion chelators and the free radical scavenger protect the cells against the lethal effect of the 99mTc; and (iii) near-UV does not alter the lethal effect of the 99mTc decay. PMID:9713950

  18. Comparison of technetium-99m-HMPAO and technetium-99m-ECD cerebral SPECT images in Alzheimer`s disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dyck, C.H. van; Lin, C.H.; Smith, E.O.

    1996-11-01

    SPECT has shown increasing promise as a diagnostic tool in Alzheimer`s disease (AD). Recently, a new SPECT brain perfusion agent, {sup 99m}Tc-ethyl cysteinate dimer ({sup 99m}Tc-ECD) has emerged with purported advantages in image quality over the established tracer, {sup 99m}Tc-hexamethylpropyleneamine oxime ({sup 99m}Tc-HMPAO). This research aimed to compare cerebral images for ({sup 99m}Tc-HMPAO). This research aimed to compare cerebral images for {sup 99}mTc-HMPAO and {sup 99m}Tc-ECD in discriminating patients with AD form control subjects. 51 refs., 5 figs., 3 tabs.

  19. Enterogastroesophageal reflux detected on 99m-technetium sestamibi cardiac imaging as a cause of chest pain

    PubMed Central

    Erdoğan, Zeynep; Silov, Güler; Özdal, Ayşegül; Turhal, Özgül

    2013-01-01

    Myocardial perfusion imaging (MPI) with technetium-99m sestamibi (Tc-99m MIBI) is considered a diagnostic technique that is widely used for the investigation of suspected coronary artery disease. Incidental inspection of an extracardiac activity is indirect, but important marker, which can identify a potentially treatable non-coronary cause for chest pain that may mimic cardiac symptoms. Here, we present an illustrative case in which significant enterogastroesophageal reflux of Tc-99m MIBI occurred during the cardiac imaging following prompt hepatobiliary clearance. Because, there was normal myocardial perfusion on MPI, presence of gastroesophageal reflux (GER) on GER scintigraphy and detection of mild inflammation with pathologically confirmed hyperplastic polyp by endoscopy, in view of the above findings we concluded that the probable cause of chest pain was reflux. PMID:24019679

  20. [Gastrointestinal bleeding from capillary hemangioma of the ileum detected by 99mTc-HSAD scintigraphy].

    PubMed

    Asano, Y; Ishii, K; Sagiuchi, T; Aoki, Y; Yanaihara, H; Hayakawa, K

    2001-05-01

    It has been well-known that technetium-99m-human serum albumin-diethylenetriaminepenta-acetic acid (99mTc-HSAD) scintigraphy is useful for diagnosis of the localization of the gastrointestinal arterial or venous bleeding. In this report, we describe a case of venous bleeding from capillary hemangioma of the ileum end detected by 99mTc-HSAD scintigraphy. This patient was a 9-year-old girl with severe anemia. Gastrointestinal bleeding was suspected from her clinical course and laboratory tests. Immediately after melena occurred, 99mTc-HSAD scintigraphy showed the extravasation of RI suggesting gastrointestinal bleeding in the ileum end. Abdominal angiography immediately after 99mTc-HSAD scintigraphy, however, could not show the extravasation of contrast agent. Because the condition of the patient became worse, laparotomy was performed on the basis of 99mTc-HSAD scintigraphy findings. At surgery, venous bleeding from capillary hemangioma in the ileum end was observed. It was suggested that 99mTc-HSAD scintigraphy was very useful for identifying the gastrointestinal venous bleeding.

  1. Detection of homing-in of stem cells labeled with technetium-99m hexamethylpropyleneamine oxime in infarcted myocardium after intracoronary injection

    PubMed Central

    Patel, Chetan D; Agarwal, Snehlata; Seth, Sandeep; Mohanty, Sujata; Aggarwal, Himesh; Gupta, Namit

    2014-01-01

    Bone marrow stem cells having myogenic potential are promising candidates for various cell-based therapies for myocardial disease. We present here images showing homing of technetium-99m (Tc-99m) hexamethylpropyleneamine oxime (HMPAO) labeled stem cells in the infarcted myocardium from a pilot study conducted to radio-label part of the stem cells in patients enrolled in a stem cell clinical trial for recent myocardial infarction. PMID:25400375

  2. Rhenium and technetium complexes that bind to amyloid-β plaques.

    PubMed

    Hayne, David J; North, Andrea J; Fodero-Tavoletti, Michelle; White, Jonathan M; Hung, Lin W; Rigopoulos, Angela; McLean, Catriona A; Adlard, Paul A; Ackermann, Uwe; Tochon-Danguy, Henri; Villemagne, Victor L; Barnham, Kevin J; Donnelly, Paul S

    2015-03-21

    Alzheimer's disease is associated with the presence of insoluble protein deposits in the brain called amyloid plaques. The major constituent of these deposits is aggregated amyloid-β peptide. Technetium-99m complexes that bind to amyloid-β plaques could provide important diagnostic information on amyloid-β plaque burden using Single Photon Emission Computed Tomography (SPECT). Tridentate ligands with a stilbene functional group were used to form complexes with the fac-[M(I)(CO)3](+) (M = Re or (99m)Tc) core. The rhenium carbonyl complexes with tridentate co-ligands that included a stilbene functional group and a dimethylamino substituent bound to amyloid-β present in human frontal cortex brain tissue from subjects with Alzheimer's disease. This chemistry was extended to make the analogous [(99m)Tc(I)(CO)3](+) complexes and the complexes were sufficiently stable in human serum. Whilst the lipophilicity (log D7.4) of the technetium complexes appeared ideally suited for penetration of the blood-brain barrier, preliminary biodistribution studies in an AD mouse model (APP/PS1) revealed relatively low brain uptake (0.24% ID g(-1) at 2 min post injection).

  3. A tracer dose of technetium-99m-labeled liposomes can estimate the effect of hyperthermia on intratumoral doxil extravasation.

    PubMed

    Kleiter, Miriam M; Yu, Daohai; Mohammadian, Lenore A; Niehaus, Nelsen; Spasojevic, Ivan; Sanders, Linda; Viglianti, Benjamin L; Yarmolenko, Pavel S; Hauck, Marlene; Petry, Neil A; Wong, Terence Z; Dewhirst, Mark W; Thrall, Donald E

    2006-11-15

    A noninvasive method to monitor intratumoral Doxil delivery in individual patients during targeted tumor therapy is important to predict treatment response. The purpose of this study was to determine if a small tracer dose of technetium-99m (99mTc)-labeled liposomes could be used to quantify the effect of local hyperthermia on intratumoral Doxil extravasation. Experiments were carried out in a rat fibrosarcoma model with transplanted thigh tumors. Liposomes of approximately same size and composition as Doxil were radiolabeled using [technetium-99m (99mTc)]exametazime. Eight treatment groups received either Doxil, a tracer dose or a large dose of 99mTc-labeled liposomes, or a combination of tracer and Doxil, with or without hyperthermia. This design was chosen to assure that coadministration of both liposomal formulations did not influence their intratumoral distribution. Hyperthermia was done for 45 minutes. Scintigraphic images were obtained at 5 and 18 hours. At 18 hours, tumors were removed and gamma counts as well as doxorubicin concentrations were measured. Intratumoral extravasation of the 99mTc-labeled tracer could be imaged scintigraphically under normothermic and hyperthermic conditions. The thermal enhancement ratio was slightly higher for radiolabeled liposomes than for doxorubicin concentration. However, there was a significant positive correlation of intratumoral doxorubicin concentration and intratumoral uptake of the radiolabeled tracer (expressed as percentage of the injected dose per gram of tissue). Coadministration of radiolabeled liposomes did not negatively influence the amount of drug delivered with Doxil. The use of a radiolabeled tracer has potential value to monitor drug delivery and estimate the effect of an intervention aimed to increase liposomal accumulation, such as local hyperthermia.

  4. Technetium-99m stannous pyrophosphate myocardial scintigraphy after cardiopulmonary resuscitation with cardioversion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Davison, R.; Spies, S.M.; Przybylek, J.

    1979-08-01

    Thirty consecutive patients underwent technetium-99m stannous pyrophosphate myocardial scintigraphy 48 to 72 h after successful cardiopulmonary resuscitation and direct current cardioversion. Five patients with transmural myocardial infarctions by ECG and enzyme determinations were correctly identified by scintigraphy. Myocardial scans were positive in five of nine patients with nontransmural infarction. Of 16 patients without evidence of myocardial infarction, only two (13%) had false-positive myocardial scans. The overall accuracy of imaging in this series was 80%. We conclude that false-positive scans after cardiopulmonary resuscitation with electrical cardioversion are infrequent, and do not significantly detract from the value of myocardial scintigraphy in themore » diagnosis of myocardial infarction.« less

  5. Method of tagging excipients with /sup 99m/Tc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bardy, A.; Beydon, J.; Gobin, R.

    1977-11-08

    A method of using /sup 99m/technetium for tagging excipients in medical diagnosis by scintigraphy comprises mixing, in an aqueous solution of alkali-metal pertechnetate, an excipient and a reducing agent in the form of a complex, which complex is such that the association constant of the anion with reduced techetium is less than the association constant of the excipient with reduced technetium, thereby forming a radio-pharmaceutical substance which is a complex between the excipient and /sup 99m/technetium.

  6. Scintigraphic detection of occult hemorrhage using RBCs labeled in vitro with technetium Tc 99m sodium pertechnetate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bunker, S.R.; Kolina, J.S.; Kaplan, K.A.

    1983-05-01

    Scintigraphy with RBCs labeled with technetium Tc 99m sodium pertechnetate effectively located the source of hemorrhage in a patient receiving long-term anticoagulant therapy. (The patient was initially seen with a large hematoma on the flank.) More important, the procedure was used to monitor activity in this otherwise-occult bleeding site. Scintigraphic studies may be useful in the management of these difficult clinical problems.

  7. Comparison of technetium-99m-HM-PAO leukocytes with indium-111-oxine leukocytes for localizing intraabdominal sepsis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mountford, P.J.; Kettle, A.G.; O'Doherty, M.J.

    Technetium-99m-HM-PAO (({sup 99m}Tc)HM-PAO) leukocyte and indium-111-oxine (111In-oxine) leukocyte scanning were carried out simultaneously in 41 patients at 4 hr and 24 hr after reinjection to determine whether the 4-hr {sup 99m}Tc scan could replace the 24-hr {sup 111}In scan for detecting intraabdominal sepsis. Abdominal infection was confirmed in 12 cases. The 4-hr {sup 99}Tc-leukocyte scan, the 4-hr {sup 111}In-leukocyte scan, and the 24-hr {sup 111}In-leukocyte scan yielded a sensitivity of 100%, 67%, and 100%, respectively, and a specificity of 62%, 90%, and 86%, respectively. The 24-hr {sup 99m}Tc-leukocyte scan also produced a sensitivity of 100%, but it was falsely positivemore » in all 29 cases without infection due to physiologic bowel uptake. False-positive 4-hr {sup 99m}Tc-leukocyte scans were also produced by physiologic bowel uptake in seven cases all of whom had true-negative 4-hr and 24-hr {sup 111}In-leukocyte scans. Because of the high incidence of false-positive 4-hr ({sup 99m}Tc)HM-PAO leukocyte scans, it was concluded that they could not replace 24-hr {sup 111}In-leukocyte scans for detecting intraabdominal sepsis, and that serial {sup 99m}Tc leukocyte scans starting earlier than 4 hr after reinjection must be evaluated.« less

  8. Value of positive myocardial technetium-99m-pyrophosphate scintigraphy in the noninvasive diagnosis of cardiac amyloidosis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wizenberg, T.A.; Muz, J.; Sohn, Y.H.

    1982-04-01

    Ten consecutive patients with tissue-proven amyloidosis, seven of whom presented with congestive heart failure, were found to exhibit intense diffuse uptake of technetium-99m-pyrophosphate (Tc-99m-PYP) on cardiac radionuclide imaging. The patients exhibited echocardiographic and systolic time interval abnormalities suggesting combined restrictive and congestive cardiomyopathic changes. On M-mode echocardiograms, there was symmetrically increased thickness of the interventricular septum and left ventricular (LV) posterior wall in diastole (10 of 10), decreased fractional shortening of the LV minor axis diameter in systole (eight of nine), and decreased percent thickening of the LV minor axis diameter in systole (eight of nine) and LV posterior wallmore » (10 of 10) in systole. Three patients demonstrated enlarged LV end-diastolic diameter. All 10 patients had abnormal PEP/LVET and eight had shortened LVETI. When combined with noninvasive tests of LV performance, positive myocardial pyrophosphate (PYP) scanning provides a new and useful adjunct in the diagnosis of amyloid heart disease.« less

  9. Amyloidosis of heart and liver: comparison of Tc-99m pyrophosphate and Tc-99m methylene diphosphonate for detection

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, V.W.; Caldarone, A.G.; Falk, R.H.

    1983-07-01

    A prospective, comparative study was made of the efficacy of technetium-99m pyrophosphate (Tc PYP) and technetium-99m methylene diphosphonate (Tc MDP) in detecting soft-tissue amyloidois. Tc PYP and Tc MDP scans were obtained within ten-day intervals in seven patients with histologically proven amyloidosis. Tc PYP was a better scanning agent for soft-tissue amyloidosis in all patients. Cardiac and hepatic involvement were proved by autopsy in one patient. Involvement of the heart was confirmed by echocardiography in five patients. The potential use of tc PYP scannning as a screening test for soft-tissue amyloidosis is discussed.

  10. Intraoperative Injection of Technetium-99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer Patients: A Single Institution Experience.

    PubMed

    Berrocal, Julian; Saperstein, Lawrence; Grube, Baiba; Horowitz, Nina R; Chagpar, Anees B; Killelea, Brigid K; Lannin, Donald R

    2017-01-01

    Background . Most institutions require a patient undergoing sentinel lymph node biopsy to go through nuclear medicine prior to surgery to be injected with radioisotope. This study describes the long-term results using intraoperative injection of radioisotope. Methods . Since late 2002, all patients undergoing a sentinel lymph node biopsy at the Yale-New Haven Breast Center underwent intraoperative injection of technetium-99m sulfur colloid. Endpoints included number of sentinel and nonsentinel lymph nodes obtained and number of positive sentinel and nonsentinel lymph nodes. Results . At least one sentinel lymph node was obtained in 2,333 out of 2,338 cases of sentinel node biopsy for an identification rate of 99.8%. The median number of sentinel nodes found was 2 and the mean was 2.33 (range: 1-15). There were 512 cases (21.9%) in which a sentinel node was positive for metastatic carcinoma. Of the patients with a positive sentinel lymph node who underwent axillary dissection, there were 242 cases (54.2%) with no additional positive nonsentinel lymph nodes. Advantages of intraoperative injection included increased comfort for the patient and simplification of scheduling. There were no radiation related complications. Conclusion . Intraoperative injection of technetium-99m sulfur colloid is convenient, effective, safe, and comfortable for the patient.

  11. Intraoperative Injection of Technetium-99m Sulfur Colloid for Sentinel Lymph Node Biopsy in Breast Cancer Patients: A Single Institution Experience

    PubMed Central

    Berrocal, Julian; Saperstein, Lawrence; Grube, Baiba; Horowitz, Nina R.; Chagpar, Anees B.

    2017-01-01

    Background. Most institutions require a patient undergoing sentinel lymph node biopsy to go through nuclear medicine prior to surgery to be injected with radioisotope. This study describes the long-term results using intraoperative injection of radioisotope. Methods. Since late 2002, all patients undergoing a sentinel lymph node biopsy at the Yale-New Haven Breast Center underwent intraoperative injection of technetium-99m sulfur colloid. Endpoints included number of sentinel and nonsentinel lymph nodes obtained and number of positive sentinel and nonsentinel lymph nodes. Results. At least one sentinel lymph node was obtained in 2,333 out of 2,338 cases of sentinel node biopsy for an identification rate of 99.8%. The median number of sentinel nodes found was 2 and the mean was 2.33 (range: 1–15). There were 512 cases (21.9%) in which a sentinel node was positive for metastatic carcinoma. Of the patients with a positive sentinel lymph node who underwent axillary dissection, there were 242 cases (54.2%) with no additional positive nonsentinel lymph nodes. Advantages of intraoperative injection included increased comfort for the patient and simplification of scheduling. There were no radiation related complications. Conclusion. Intraoperative injection of technetium-99m sulfur colloid is convenient, effective, safe, and comfortable for the patient. PMID:28492062

  12. Importance of methodology on (99m)technetium dimercapto-succinic acid scintigraphic image quality: imaging pilot study for RIVUR (Randomized Intervention for Children With Vesicoureteral Reflux) multicenter investigation.

    PubMed

    Ziessman, Harvey A; Majd, Massoud

    2009-07-01

    We reviewed our experience with (99m)technetium dimercapto-succinic acid scintigraphy obtained during an imaging pilot study for a multicenter investigation (Randomized Intervention for Children With Vesicoureteral Reflux) of the effectiveness of daily antimicrobial prophylaxis for preventing recurrent urinary tract infection and renal scarring. We analyzed imaging methodology and its relation to diagnostic image quality. (99m)Technetium dimercapto-succinic acid imaging guidelines were provided to participating sites. High-resolution planar imaging with parallel hole or pinhole collimation was required. Two core reviewers evaluated all submitted images. Analysis included appropriate views, presence or lack of patient motion, adequate magnification, sufficient counts and diagnostic image quality. Inter-reader agreement was evaluated. We evaluated 70, (99m)technetium dimercapto-succinic acid studies from 14 institutions. Variability was noted in methodology and image quality. Correlation (r value) between dose administered and patient age was 0.780. For parallel hole collimator imaging good correlation was noted between activity administered and counts (r = 0.800). For pinhole imaging the correlation was poor (r = 0.110). A total of 10 studies (17%) were rejected for quality issues of motion, kidney overlap, inadequate magnification, inadequate counts and poor quality images. The submitting institution was informed and provided with recommendations for improving quality, and resubmission of another study was required. Only 4 studies (6%) were judged differently by the 2 reviewers, and the differences were minor. Methodology and image quality for (99m)technetium dimercapto-succinic acid scintigraphy varied more than expected between institutions. The most common reason for poor image quality was inadequate count acquisition with insufficient attention to the tradeoff between administered dose, length of image acquisition, start time of imaging and resulting image

  13. Comparison of technetium-99m sulfur colloid and technetium-99m albumin colloid labeled solid meals for gastric emptying studies.

    PubMed

    Taillefer, R; Douesnard, J M; Beauchamp, G; Guimond, J

    1987-08-01

    A Tc-99m albumin colloid (Tc-AC) kit has been introduced as an alternative to Tc-99m sulfur colloid (Tc-SC) for liver-spleen imaging. Since there is no need for boiling, the use of Tc-AC reduces preparation time and manipulation. Tc-SC is one of the most commonly used radiopharmaceuticals for the labeling of solid-phase markers in gastric emptying studies. In vitro studies were performed to evaluate the labeling efficiency and stability in hydrochloric acid and in human gastric juice of intracellularly labeled chicken liver and scrambled eggs labeled with Tc-SC and Tc-AC. Gastric emptying studies also were performed on 20 healthy volunteers with both Tc-SC and Tc-AC labeled scrambled egg sandwiches. There was no significant difference between Tc-SC and Tc-AC in the labeling efficiency of chicken liver (98% +/- 1% for Tc-SC, 96% +/- 2% for Tc-AC) and scrambled eggs (92% +/- 2% for Tc-SC, 91% +/- 3% for Tc-AC). However, both Tc-SC and Tc-AC labeled scrambled eggs showed a lower stability than chicken liver, particularly in human gastric juice. Gastric emptying curves from both meals in 20 normal subjects were also similar, with a mean half-emptying time of 85 +/- 13 minutes and 87 +/- 16 minutes for the meals containing Tc-SC and Tc-AC respectively. Tc-AC is a reliable alternative to Tc-SC as a radiotracer for solid-phase gastric emptying studies.

  14. [Situation of supply and boom of PET imaging: what is the future for technetium-99m in nuclear medicine?].

    PubMed

    Maia, S; Ayachi Hatit, N; Paycha, F

    2011-05-01

    Molecular imaging has shown its interest in the diagnosis, staging and therapy monitoring of many diseases, especially in the field of cancer. This imaging modality can detect non-invasively early molecular changes specific to these diseases. Its expansion includes two aspects linked firstly with the advanced techniques of imaging modalities and secondly with the development of tracers as radio pharmaceuticals for imaging new molecular targets. Technetium-99m ((99m)Tc), because of its physical characteristics, its widespread availability and low cost, is the most used radionuclide in molecular imaging with the technique of single photon emission computed tomography (SPECT). Nevertheless, the current difficulty concerning the supply and the great interest of Positron Emission Tomography (PET), the "competitor" imaging modality-using molecules labelled with fluorine-18 ((18)F), legitimates the question about the future of (99m)Tc, its supremacy and the emergence of new tracer labelled with (99m)Tc. Focusing on the actual and future supply situation, the place of SPECT imaging in nuclear medicine, as well as the development of new molecules labelled with (99m)Tc is necessary to show that this radionuclide will remain essential for the speciality in the next years. Copyright © 2011 Elsevier Masson SAS. All rights reserved.

  15. The role of technetium-99m stannous pyrophosphate in myocardial imaging to recognize, localize and identify extension of acute myocardial infarction in patients

    NASA Technical Reports Server (NTRS)

    Willerson, J. T.; Parkey, R. W.; Bonte, F. J.; Stokely, E. M.; Buja, E. M.

    1975-01-01

    The ability of technetium-99m stannous pyrophosphate myocardial scintigrams to aid diagnostically in recognizing, localizing, and identifying extension of acute myocardial infarction in patients was evaluated. The present study is an extension of previous animal and patient evaluations that were recently performed utilizing this myocardial imaging agent.

  16. Evolution of technetium-99m-HMPAO SPECT and brain mapping in a patient presenting with echolalia and palilalia.

    PubMed

    Dierckx, R A; Saerens, J; De Deyn, P P; Verslegers, W; Marien, P; Vandevivere, J

    1991-08-01

    A 78-yr-old woman presented with transient echolalia and palilalia. She had suffered from Parkinson's disease for 2 yr. Routine laboratory examination showed hypotonic hyponatremia, but was otherwise unremarkable. Brain mapping revealed a bifrontal delta focus, more pronounced on the right. Single photon emission computed tomography (SPECT) of the brain with technetium-99m labeled d,l hexamethylpropylene-amine oxime (99mTc-HMPAO), performed during the acute episode showed relative frontoparietal hypoactivity. Brain mapping performed after disappearance of the echolalia and palilalia, which persisted only for 1 day, was normal. By contrast, SPECT findings persisted for more than 3 wk. Features of particular interest in the presented patient are the extensive defects seen on brain SPECT despite the absence of morphologic lesions, the congruent electrophysiologic changes and their temporal relationship with the clinical evolution.

  17. Eosinophilic enterocolitis diagnosed by means of technetium-99m albumin scintigraphy and treated with budesonide (CIR).

    PubMed Central

    Russel, M G; Zeijen, R N; Brummer, R J; de Bruine, A P; van Kroonenburgh, M J; Stockbrügger, R W

    1994-01-01

    A patient with a 15 year history of diarrhoea of unknown origin is described. Scintigraphy with technetium-99m labelled albumin suggested albumin loss at the terminal ileum and caecum; subsequent colonoscopic biopsies of these macroscopically normal looking areas showed abundant infiltration with eosinophils. A diagnosis of eosinophilic enterocolitis was made. Treatment with prednisolone had good results, but had to be stopped because of severe side effects. Oral cromoglycate and mesalazine were not effective. Budesonide (CIR), a new topically active corticosteroid with very little systemic effects, was at least as effective as prednisolone without producing side effects. Images Figure 1 Figure 2 Figure 3 Figure 4 PMID:7959211

  18. Effect of Thuya occidentalis on the labeling of red blood cells and plasma proteins with technetium-99m.

    PubMed Central

    Oliveira, J. F.; Braga, A. C.; Avila, A. S.; Fonseca, L. M.; Gutfilen, B.; Bernardo-Filho, M.

    1996-01-01

    Thuya occidentalis is used in popular medicine in the treatment of condyloma and has antibacterial action. Red blood cells (RBC) labeled with technetium-99m (99mTc) are used for several evaluations in nuclear medicine. This labeling depends on a reducing agent, usually stannous ion. Any drug which alters the labeling of the tracer could be expected to modify the disposition of the radiopharmaceutical. We have evaluated the influence of T. occidentalis extract on the labeling of RBC and plasma proteins with 99mTc. Blood was withdrawn and incubated with T. occidentalis (0.25; 2.5; 20.5; and 34.1 percent v/v). Stannous chloride (1.2 micrograms/ml) was added and then 99mTc was added. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) separated. The analysis of the results shows that there is a decrease in radioactivity (from 97.64 to 75.89 percent) in BC with 34.1 percent of the drug. In the labeling process of RBC with 99mTc, the stannous and pertechnetate ions pass through the membrane, so we suggest that the T. occidentalis effect can be explained (i) by an inhibition of the transport of these ions, (ii) by damage in membrane, (iii) by competition with the cited ions for the same binding sites, or (iv) by possible generation of reactive oxygen species that could oxidize the stannous ion. PMID:9436292

  19. Effect of Thuya occidentalis on the labeling of red blood cells and plasma proteins with technetium-99m.

    PubMed

    Oliveira, J F; Braga, A C; Avila, A S; Fonseca, L M; Gutfilen, B; Bernardo-Filho, M

    1996-01-01

    Thuya occidentalis is used in popular medicine in the treatment of condyloma and has antibacterial action. Red blood cells (RBC) labeled with technetium-99m (99mTc) are used for several evaluations in nuclear medicine. This labeling depends on a reducing agent, usually stannous ion. Any drug which alters the labeling of the tracer could be expected to modify the disposition of the radiopharmaceutical. We have evaluated the influence of T. occidentalis extract on the labeling of RBC and plasma proteins with 99mTc. Blood was withdrawn and incubated with T. occidentalis (0.25; 2.5; 20.5; and 34.1 percent v/v). Stannous chloride (1.2 micrograms/ml) was added and then 99mTc was added. Plasma (P) and blood cells (BC) were isolated, also precipitated with trichloroacetic acid and soluble (SF) and insoluble fractions (IF) separated. The analysis of the results shows that there is a decrease in radioactivity (from 97.64 to 75.89 percent) in BC with 34.1 percent of the drug. In the labeling process of RBC with 99mTc, the stannous and pertechnetate ions pass through the membrane, so we suggest that the T. occidentalis effect can be explained (i) by an inhibition of the transport of these ions, (ii) by damage in membrane, (iii) by competition with the cited ions for the same binding sites, or (iv) by possible generation of reactive oxygen species that could oxidize the stannous ion.

  20. Determination of technetium-99 in environmental samples: a review.

    PubMed

    Shi, Keliang; Hou, Xiaolin; Roos, Per; Wu, Wangsuo

    2012-01-04

    Due to the lack of a stable technetium isotope, and the high mobility and long half-life, (99)Tc is considered to be one of the most important radionuclides in safety assessment of environmental radioactivity as well as nuclear waste management. (99)Tc is also an important tracer for oceanographic research due to the high technetium solubility in seawater as TcO(4)(-). A number of analytical methods, using chemical separation combined with radiometric and mass spectrometric measurement techniques, have been developed over the past decades for determination of (99)Tc in different environmental samples. This article summarizes and compares recently reported chemical separation procedures and measurement methods for determination of (99)Tc. Due to the extremely low concentration of (99)Tc in environmental samples, the sample preparation, pre-concentration, chemical separation and purification for removal of the interferences for detection of (99)Tc are the most important issues governing the accurate determination of (99)Tc. These aspects are discussed in detail in this article. Meanwhile, the different measurement techniques for (99)Tc are also compared with respect to advantages and drawbacks. Novel automated analytical methods for rapid determination of (99)Tc using solid extraction or ion exchange chromatography for separation of (99)Tc, employing flow injection or sequential injection approaches are also discussed. Copyright © 2011 Elsevier B.V. All rights reserved.

  1. Measurement of technetium-99 in Marshall Islands soil samples by ICP-MS

    PubMed

    Tagami; Uchida; Hamilton; Robison

    2000-07-01

    Extraction techniques for recovery of technetium-99 (99Tc) for Inductively Coupled Plasma Mass Spectrometry (ICP-MS) measurements were evaluated using soil samples collected from the Marshall Islands. The results of three different extraction techniques were compared: (MI) acid leaching of Tc from ashed soil; (M2) acid leaching of Tc from raw dry soil; and (M3) Tc volatilization from ashed soil using a combustion apparatus. Total Tc recoveries varied considerably between the extraction techniques but each method yielded similar analytical results for 99Tc. Applications of these extraction techniques to a series of environmental samples and ICP-MS measurements have yielded first data on the 99Tc content of Marshall Islands soil samples contaminated with close-in radioactive fallout from nuclear weapons testing. The 99Tc activity concentration in the soil samples ranged between 0.1 and 1.1 mBq g(-1) dry weight (dw). The limit of detection for 99Tc by ICP-MS was 0.17 mBq per sample or 0.014 mBq g(-1) dw under standard operating conditions.

  2. 99mTc-D(LPR): A novel retro-inverso peptide for VEGF receptor-1 targeted tumor imaging.

    PubMed

    Rezazadeh, Farzaneh; Sadeghzadeh, Nourollah; Abedi, Seyed Mohammad; Abediankenari, Saeid

    2018-05-31

    The aim of this study was to evaluate the ability of D (LPR), a novel retro-inverso peptidomimetic derivative for imaging colon cancer. Two different D (LPR) analogs were designed and compared based on conjugation of HYNIC at peptide's C or N terminal and then labeled with technetium-99m using tricine/EDDA as an exchange coligands. The radiolabeled conjugates were assessed for in vitro stability in saline and serum. The VEGFR-1 and NRP-1 receptors affinity, in vitro internalization and also dissociation Constance was evaluated. SPCET imaging and biodistribution studies were performed in nude mice bearing HT-29 xenograft tumors. Both peptides labeled with technetium-99m in high radiochemical yield (˃97%). Peptide stability studies indicated a high metabolic stability of the radiopeptides in solution and serum. In vitro blocking studies demonstrated specific binding and internalization of [ 99m Tc]Tc-HYNIC-peptides in cultured HUVEC cells. The K d value for 99m Tc-peptide 1 and 99m Tc-peptide 2 were found to be 56.8 ± 12.9 nM and 71.6 ± 17.9 nM respectively. The tumor to muscle ratio was significant at 0.5 and 1 h after injection (4.5 and 4 for 99m Tc-peptide 1 and 4.9 and 4.4 for 99m Tc-peptide 2 at 0.5 and 1 h p.i. respectively). SPECT imaging studies revealed that both radioconjugates had prominent activity accumulation in VEGFR-1 and NRP-1 expressing HT-29 tumors. This study is the first instance of using a radiolabeled retro-inverso peptide for tumor imaging which is a promising tool to improve the performance of fragile peptide probes in vivo as imaging agents and warrant further investigations in other peptide-target systems. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Utility of 99mTc-Hynic-TOC in 131I Whole-Body Scan Negative Thyroid Cancer Patients with Elevated Serum Thyroglobulin Levels

    PubMed Central

    Shinto, Ajit S.; Kamaleshwaran, K. K.; Mallia, Madhav; Korde, Aruna; Samuel, Grace; Banerjee, Sharmila; Velayutham, Pavanasam; Damodharan, Suresh; Sairam, Madhu

    2015-01-01

    Several studies have reported on the expression of somatostatin receptors (SSTRs) in patients with differentiated thyroid cancer (DTC). The aim of this study was to evaluate the imaging abilities of a recently developed Technetium-99m labeled somatostatin analog, 99mTc-Hynic-TOC, in terms of precise localization of the disease. The study population consisted of 28 patients (16 men, 12 women; age range: 39-72 years) with histologically confirmed DTC, who presented with recurrent or persistent disease as indicated by elevated serum thyroglobulin (Tg) levels after initial treatment (serum Tg > 10 ng/ml off T4 suppression for 4-6 weeks). All patients were negative on the Iodine-131 posttherapy whole-body scans. Fluorine-18 fluorodeoxyglucose positron emission tomography (18F-FDG PET) was performed in all patients. SSTR scintigraphy was true positive in 23 cases (82.1%), true negative in two cases (7.1%) and false negative in three cases (10.7%) which resulted in a sensitivity of 88.46%, specificity of 100% and an accuracy of 89.2%. Sensitivity of 99mTc-Hynic-TOC scan was higher (93.7%) for patients with advanced stages, that is stages III and IV. 18F-FDG showed a sensitivity of 93.7%, a specificity of 50% and an accuracy of 89.3%. 18F-FDG PET was found to be more sensitive, with lower specificity due to false positive results in 2 patients. Analysis on a lesion basis demonstrated substantial agreement between the two imaging techniques with a Cohen's kappa of 0.66. Scintigraphy with 99mTc-Hynic-TOC might be a promising tool for treatment planning; it is easy to perform and showed sufficient accuracy for localization diagnostics in thyroid cancer patients with recurrent or metastatic disease. PMID:26097420

  4. Utility of (99m)Tc-Hynic-TOC in 131I Whole-Body Scan Negative Thyroid Cancer Patients with Elevated Serum Thyroglobulin Levels.

    PubMed

    Shinto, Ajit S; Kamaleshwaran, K K; Mallia, Madhav; Korde, Aruna; Samuel, Grace; Banerjee, Sharmila; Velayutham, Pavanasam; Damodharan, Suresh; Sairam, Madhu

    2015-01-01

    Several studies have reported on the expression of somatostatin receptors (SSTRs) in patients with differentiated thyroid cancer (DTC). The aim of this study was to evaluate the imaging abilities of a recently developed Technetium-99m labeled somatostatin analog, (99m)Tc-Hynic-TOC, in terms of precise localization of the disease. The study population consisted of 28 patients (16 men, 12 women; age range: 39-72 years) with histologically confirmed DTC, who presented with recurrent or persistent disease as indicated by elevated serum thyroglobulin (Tg) levels after initial treatment (serum Tg > 10 ng/ml off T4 suppression for 4-6 weeks). All patients were negative on the Iodine-131 posttherapy whole-body scans. Fluorine-18 fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) was performed in all patients. SSTR scintigraphy was true positive in 23 cases (82.1%), true negative in two cases (7.1%) and false negative in three cases (10.7%) which resulted in a sensitivity of 88.46%, specificity of 100% and an accuracy of 89.2%. Sensitivity of (99m)Tc-Hynic-TOC scan was higher (93.7%) for patients with advanced stages, that is stages III and IV. (18)F-FDG showed a sensitivity of 93.7%, a specificity of 50% and an accuracy of 89.3%. (18)F-FDG PET was found to be more sensitive, with lower specificity due to false positive results in 2 patients. Analysis on a lesion basis demonstrated substantial agreement between the two imaging techniques with a Cohen's kappa of 0.66. Scintigraphy with (99m)Tc-Hynic-TOC might be a promising tool for treatment planning; it is easy to perform and showed sufficient accuracy for localization diagnostics in thyroid cancer patients with recurrent or metastatic disease.

  5. 99mTechnetium-based Prostate-specific Membrane Antigen-radioguided Surgery in Recurrent Prostate Cancer.

    PubMed

    Maurer, Tobias; Robu, Stephanie; Schottelius, Margret; Schwamborn, Kristina; Rauscher, Isabel; van den Berg, Nynke S; van Leeuwen, Fijs W B; Haller, Bernhard; Horn, Thomas; Heck, Matthias M; Gschwend, Jürgen E; Schwaiger, Markus; Wester, Hans-Jürgen; Eiber, Matthias

    2018-04-03

    Prostate-specific membrane antigen (PSMA)-targeted positron emission tomography (PET) can visualize metastatic lesions in recurrent prostate cancer (PC). However, reliable identification of small and/or atypically localized lesions during salvage surgery procedures is challenging. To describe the technique, feasibility, and short-term outcomes of 99m Technetium ( 99m Tc)-based PSMA-radioguided surgery ( 99m Tc-PSMA-RGS) for removal of recurrent PC lesions. Thirty-one consecutive patients with evidence of recurrent PC on 68 Ga-PSMA N,N'-bis[2-hydroxy-5-(carboxyethyl)benzyl] ethylenediamine-N,N'-diacetic acid ( 68 Ga-PSMA-11) PET after radical prostatectomy undergoing 99m Tc-PSMA-RGS were retrospectively analyzed. Salvage surgery with intraoperative radioguidance using a gamma probe was performed after intravenous application of 99m Tc-PSMA investigation and surgery (mean activity 571 MBq, mean time to surgery 19.7h). Radioactive rating (positive vs negative) of resected tissue was compared with the findings of postoperative histopathological analysis. Best prostate-specific antigen (PSA) response without additional treatment was determined after 8-16 wk postoperatively. Biochemical recurrence- and treatment-free survival was evaluated. In total, 132 tissue specimens were removed, of which 58 showed metastatic involvement on histological analysis. On a specimen basis, radioactive rating yielded a sensitivity of 83.6% (confidence interval [CI]: 70.9-91.5%), a specificity of 100%, and an accuracy of 93.0% (CI: 85.5-96.7%). With 99m Tc-PSMA-RGS, all lesions visualized on preoperative 68 Ga-PSMA-11 PET could be removed. Moreover, 99m Tc-PSMA-RGS detected additional metastases as small as 3mm in two patients. Thirteen patients suffered from complications related to surgery (Clavien-Dindo grade 1: 12 patients; grade 3a: one patient). A PSA reduction below 0.2 ng/ml was observed in 20 patients. Thirteen patients remained biochemical recurrence free after a median follow

  6. Detecting Myocardial Ischemia With 99mTechnetium-Tetrofosmin Myocardial Perfusion Imaging in Ischemic Stroke.

    PubMed

    Giannopoulos, Sotirios; Markoula, Sofia; Sioka, Chrissa; Zouroudi, Sofia; Spiliotopoulou, Maria; Naka, Katerina K; Michalis, Lampros K; Fotopoulos, Andreas; Kyritsis, Athanassios P

    2017-10-01

    To assess the myocardial status in patients with stroke, employing myocardial perfusion imaging (MPI) with 99m Technetium-tetrofosmin ( 99m Tc-TF)-single-photon emission computed tomography (SPECT). Fifty-two patients with ischemic stroke were subjected to 99m Tc-TF-SPECT MPI within 1 month after stroke occurrence. None of the patients had any history or symptoms of coronary artery disease or other heart disease. Myocardial perfusion imaging was evaluated visually using a 17-segment polar map. Myocardial ischemia (MIS) was defined as present when the summed stress score (SSS) was >4; MIS was defined as mild when SSS was 4 to 8, and moderate/severe with SSS ≥9. Patients with SSS >4 were compared to patients with SSS <4. Parameters such as age, body mass index, waist perimeter, smoking habits, and medical history (diabetes mellitus, dyslipidemia, etc) were evaluated according to MPI results. Myocardial ischemia was present in 32 (62%) of 52 patients with stroke. Among them, 20 (62%) of 32 patients had mild abnormalities and 12 (38%) of 32 had moderate/severe. The age and waist perimeter showed a tendency to relate to severe MIS when patients with SSS >9 were compared to patients with SSS <4. In MPI-positive patients, an age was to be association with SSS, with the oldest age exhibiting the highest SSS ( P = .01). The association of age with SSS remained statistically significant in the multivariate analysis ( P = .04). The study suggested that more than half of patients with stroke without a history of cardiac disease have MIS. Although most of them have mild MIS, we suggest a thorough cardiological evaluation in this group of patients for future prevention of severe myocardial outcome.

  7. Diffusion of 99-technetium in compacted bentonite under aerobic and anaerobic conditions

    NASA Astrophysics Data System (ADS)

    Večerník, P.; Jedináková-Křížová, V.

    2006-01-01

    The main aim of this study was to investigate diffusion of technetium 99Tc under different conditions. Because technetium represents one of the most dangerous fission products due to its very long halftime and high mobility in aerobic conditions diffusion experiments of technetium (as 99TcO 4 - anion) in Czech bentonite from Rokle locality have been carried out. For performance and evaluation of experiments the through-diffusion method was chosen and apparent (Da) and effective (De) diffusion coefficients were evaluated. The effects of particle mesh-size, dry bulk density and aerobic or anaerobic conditions on diffusion were studied. In the presence of oxygen, technetium occurs in oxidation state VII, as an anion, soluble and mobile in the environment. However, under reducing conditions it occurs in a lower oxidation states, mainly as insoluble oxides or hydroxides. Aerobic experiments were carried out under laboratory conditions and anaerobic experiments were performed in a nitrogen atmosphere in a glove box, to simulate the real underground conditions.

  8. Effect of metabolic alterations on the accumulation of technetium-99m-labeled d, l-HMPAO in slices of rat cerebral cortex

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ahn, C.S.; Tow, D.E.; Yu, C.C.

    1994-03-01

    It is widely recognized that the distribution of technetium-99m-labeled d,l-hexamethylpropylene amine oxime ({sup 99m}Tc-HMPAO) in the brain is determined by the regional blood flow. However, other factors may affect this process including the metabolism of the brain tissue. To examine this possibility we studied the effects of metabolic alterations on {sup 99m}Tc-HMPAO uptake in rat brain cortex slices, with concurrent measurement of oxygen consumption (QO{sub 2}). {sup 99m}Tc-HMPAO uptake was determined by incubating slices of rat cerebral cortex at 37{degrees}C in Krebs-Ringer phosphate glucose medium containing {sup 99m}Tc-HMPAO with and without test substances. Differential gradients for {sup 99m}Tc activity betweenmore » the tissue and the suspending medium (T/M ratio) were derived from the equation T/M[{sup 99m}Tc] = counts per gram of tissue/counts per milliliter of medium. The QO{sub 2} of the brain slices was measured using a biological oxygen monitor equipped with a polarographic oxygen probe. Inhibitors affecting oxidative phosphorylation caused parallel suppression of the T/M ratio and QO{sub 2}. Agents that uncouple oxidation from phosphorylation increased the QO{sub 2} and decreased the T/M ratio. Incubation of slices at 22{degrees}C depressed the T/M ratio and QO{sub 2}. The presence of inhibitors of oxidative phosphorylation in the incubation medium increased the release of {sup 99m}Tc activity from slices that had been prelabeled with {sup 99m}Tc-HMPAO. These findings suggest that the altered metabolic status of the brain tissue modulates the kinetics and net accumulation of {sup 99m}Tc-HMPAO at the cellular level by either depressing uptake, increasing back-diffusion, or both. 33 refs., 4 figs., 3 tabs.« less

  9. Utility of ⁹⁹mTc-human serum albumin diethylenetriamine pentaacetic acid SPECT for evaluating endoleak after endovascular abdominal aortic aneurysm repair.

    PubMed

    Nakai, Motoki; Sato, Hirotatsu; Sato, Morio; Ikoma, Akira; Sonomura, Tetsuo; Nishimura, Yoshiharu; Okamura, Yoshitaka

    2015-01-01

    The purpose of this study was to assess the utility of (99m)Tc-human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) SPECT in the detection of endoleaks after endovascular abdominal aortic aneurysm repair. Fifteen patients (11 men, four women) with aneurysm sac expansion of 5 mm or greater after endovascular abdominal aortic aneurysm repair underwent three-phase CT, (99m)Tc-HSAD SPECT, and CT during aortography. Sensitivity calculations for three-phase CT and (99m)Tc-HSAD SPECT were performed with CT during aortography as the reference standard. The volume of each endoleak was measured with CT during aortography. Seven subjects underwent embolization with N-butyl cyanoacrylate (NBCA)-Lipiodol (ethiodized oil, Guerbet and metallic coils. Three-phase CT and (99m)Tc-HSAD SPECT were repeated after embolization to assess their efficacy. Endoleaks were interpreted as perigraft radioisotope accumulation in 12 patients (80.0%) on (99m)Tc-HSAD SPECT images, in 13 patients (86.7%) on three-phase CT images, and in 15 patients (100%) on CT during aortography. The mean endoleak volume visualized with (99m)Tc-HSAD SPECT was 8.37 cm(3) (range, 5.2-15.1 cm(3)), and the volume not visualized was 3.47 cm(3) (2.5-4.6 cm(3)), a statistically significant difference (p = 0.019). In two patients, (99m)Tc-HSAD SPECT depicted endoleaks evident at delayed phase CT during aortography but not at three-phase CT, suggesting they were slow-filling endoleaks. Accumulation of (99m)Tc-HSAD corresponding to endoleaks disappeared after embolization, but CT evaluation of embolization was impeded by artifacts of NBCA-Lipiodol and metallic coils. Technetium-99m-labeled HSAD SPECT proved less sensitive than three-phase CT but depicted endoleaks with volumes 5.2 cm(3) or greater as perigraft radioisotope accumulation. Slow-filling endoleaks can be visualized with (99m)Tc-HSAD SPECT, which can be used to evaluate the efficacy of embolization.

  10. Rapid and accurate diagnosis of acute cholecystitis with /sup 99m/Tc-HIDA cholescintigraphy. [HIDA = dimethyl acetanilide iminodiacetic acid

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weissmann, H.S.; Frank, M.S.; Bernstein, L.H.

    1979-04-01

    Technetium-99m dimethyl acetanilide iminodiacetic acid (HIDA) cholescintigraphy was performed on 90 patients with suspected acute cholecytitis. Visualization of the gallbladder established patency of the cystic duct and excluded the diagnosis of acute cholecystitis in 50 of 52 patients. Nonvisualization of the gallbladder with visualization of the common bile duct was diagnostic of acute cholecystitis in 38 patients, all subsequently proven at surgery. The observed accuracy of this procedure is 98% and specificity is 100%. The false negative rate is 5% and false positive rate is zero. Technetium-99m-HILDA has many advantages which make it the procedure of choice in evaluating amore » patient for suspected acute cholecystitis. It is a rapid, simple, safe examination which provides functional as well as anatomic information about the hepatobiliary system in individuals with a serum bilirubin level up to 8 mg/100 ml.« less

  11. Technetium-99m-Labeled Sulfadiazine: a Targeting Radiopharmaceutical for Scintigraphic Imaging of Infectious Foci Due To Escherichia coli in Mouse and Rabbit Models.

    PubMed

    Ahmed, Muhammad Tauqeer; Naqvi, Syed Ali Raza; Rasheed, Rashid; Zahoor, Ameer Fawad; Usman, Muhammad; Hussain, Zaib

    2017-09-01

    Bacterial infection is one of the vital reasons of morbidity and mortality, especially in developing countries. It appears silently without bothering the geological borders and imposes a grave threat to humanity. Nuclear medicine technique has an important role in helping early diagnosis of deep-seated infections. The aim of this study was to develop a new radiopharmaceutical 99m Tc-labeling sulfadiazine as an infection imaging agent. Radiolabeling of sulfadiazine with technetium-99m ( 99m Tc) was carried out using stannous tartrate as a reducing agent in the presence of gentistic acid at pH = 5. The quality control tests revealed ~98% labeling efficiency. Paper chromatographic (PC) and instant thin-layer chromatographic (ITLC) techniques were used to analyze radiochemical yield. Biodistribution and infection specificity of the radiotracer were performed with Escherichia coli (E. coli) infection-induced rats. Scintigraphy and glomerular filtration rate (GFR) study was performed in E. coli-infected rabbits. Scintigraphy indicated E. coli infection targeting potential of 99m Tc-SDZ, while biodistribution study showed minimal uptake of 99m Tc-SDZ in non-targeted tissues. The uptake in the kidneys was found 2.56 ± 0.06, 2.09 ± 0.10, and 1.68 ± 0.09% at 30 min, 1 h, and 4 h, respectively. The infected muscle (target) to non-infected muscle (non-target) ratio (T/NT) was found 4.49 ± 0.04, 6.78 ± 0.07, and 5.59 ± 0.08 at 30 min, 1 h, and 4 h, respectively.

  12. Early identification of amyloid heart disease by technetium-99m-pyrophosphate scintigraphy: a study with familial amyloid polyneuropathy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hongo, M.; Hirayama, J.; Fujii, T.

    1987-03-01

    To determine whether technetium-99m-pyrophosphate (Tc-99m-PYP) scanning or two-dimensional echocardiography can detect amyloid heart disease in an earlier stage of familial amyloid polyneuropathy, 15 patients were examined. Although 10 of the 15 patients had no clinical evidence of congestive heart failure, as well as normal ventricular wall thickness and normal values for left ventricular systolic function, five (50%) of them showed mild or moderate myocardial uptake. On the other hand, none had characteristic highly refractile myocardial echoes on the two-dimensional echocardiographic images (p less than 0.01), and values for diastolic function were reduced in four of the five and normal inmore » the remaining one. In 85 control subjects, diffuse positive pyrophosphate scans of the heart were found in four (5%) of them (three with dilated cardiomyopathy and one with sarcoidosis), and highly refractile granular sparkling echoes were observed in nine (11%) (five with hypertrophic cardiomyopathy, three with aortic stenosis, and one with hypereosinophilic syndrome). We conclude that Tc-99m-PYP scanning is a more sensitive and specific method and may have the potential ability to detect amyloid heart disease in the earlier stage of familial amyloid polyneuropathy than two-dimensional echocardiography.« less

  13. In-house cyclotron production of high-purity Tc-99m and Tc-99m radiopharmaceuticals.

    PubMed

    Martini, Petra; Boschi, Alessandra; Cicoria, Gianfranco; Zagni, Federico; Corazza, Andrea; Uccelli, Licia; Pasquali, Micòl; Pupillo, Gaia; Marengo, Mario; Loriggiola, Massimo; Skliarova, Hanna; Mou, Liliana; Cisternino, Sara; Carturan, Sara; Melendez-Alafort, Laura; Uzunov, Nikolay M; Bello, Michele; Alvarez, Carlos Rossi; Esposito, Juan; Duatti, Adriano

    2018-05-30

    In the last years, the technology for producing the important medical radionuclide technetium-99m by cyclotrons has become sufficiently mature to justify its introduction as an alternative source of the starting precursor [ 99m Tc][TcO 4 ] - ubiquitously employed for the production of 99m Tc-radiopharmaceuticals in hospitals. These technologies make use almost exclusively of the nuclear reaction 100 Mo(p,2n) 99m Tc that allows direct production of Tc-99m. In this study, it is conjectured that this alternative production route will not replace the current supply chain based on the distribution of 99 Mo/ 99m Tc generators, but could become a convenient emergency source of Tc-99m only for in-house hospitals equipped with a conventional, low-energy, medical cyclotron. On this ground, an outline of the essential steps that should be implemented for setting up a hospital radiopharmacy aimed at the occasional production of Tc-99m by a small cyclotron is discussed. These include (1) target production, (2) irradiation conditions, (3) separation/purification procedures, (4) terminal sterilization, (5) quality control, and (6) Mo-100 recovery. To address these issues, a comprehensive technology for cyclotron-production of Tc-99m, developed at the Legnaro National Laboratories of the Italian National Institute of Nuclear Physics (LNL-INFN), will be used as a reference example. Copyright © 2018 Elsevier Ltd. All rights reserved.

  14. Validation of an ergonomic method to withdraw [99mTc] radiopharmaceuticals.

    PubMed

    Blondeel-Gomes, Sandy; Marie, Solène; Fouque, Julien; Loyeau, Sabrina; Madar, Olivier; Lokiec, François

    2017-11-10

    The main objective of the present work was to ensure quality of radiopharmaceuticals syringes withdrawn with a "Spinal needle/obturator In-Stopper" system. Methods: Visual examinations and physicochemical tests are performed at T0 and T+4h for [ 99m Tc]albumin nanocolloid and T+7h for [ 99m Tc]eluate, [ 99m Tc] HydroxyMethylene DiPhosphonate and [ 99m Tc]Human Serum Albumin. Microbiological validation was performed according to European pharmacopoeia. Fingertip radiation exposure was evaluated to confirm the safety of the system. Results: Results show stable visual and physicochemical properties. The integrity of the connector was not affected after 30 punctures (no cores). No microbiological contamination was found on tested syringes. Conclusion: The system could be used 30 times. The stability of syringes drawing with this method is guaranteed up to 4 hours for [ 99m Tc]albumin nanocolloid and 7 hours for [ 99m Tc]eluate, [ 99m Tc]HydroxyMethylene DisPhosphonate and [ 99m Tc]Human serum albumin. Copyright © 2017 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  15. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement.

    PubMed

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    99m Technetium-methylene diphosphonate ( 99m Tc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99m Tc-MDP-bone scan images. A set of 89 low contrast 99m Tc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t -test was applied, and a statistically significant difference in the input and processed image quality was found at P < 0.001 (with α = 0.05). However, further improvement in image quality is needed as per requirements of nuclear medicine physicians. GHE techniques can be used on low contrast bone scan images. In some of the cases, a histogram equalization technique in combination with some other postprocessing technique is useful.

  16. Influence of exercise on the distribution of technetium Tc 99m medronate following intra-articular injection in horses.

    PubMed

    Dulin, Jennifer A; Drost, W Tod; Phelps, Mitch A; Santschi, Elizabeth M; Menendez, Maria I; Bertone, Alicia L

    2012-03-01

    To determine the effects of exercise on the distribution and pharmacokinetics of technetium Tc 99m medronate ((99m)Tc-MDP) following intra-articular (IA) injection in horses. 5 horses. 1 antebrachiocarpal joint (ACJ)/horse was assigned to the exercised group (n = 5), and the contralateral ACJ was evaluated in the nonexercised group (5) after a minimum washout period of 7 days. Following IA injection of (99m)Tc-MDP (148 MBq), blood and scintigraphic images of the carpus were obtained at 5, 10, 15, 20, 25, 30, 45, 60, 90, 120, 240, 360, 480, 600, 720, and 1,440 minutes. Plasma and scintigraphic radioactivity were determined over time, and pharmacokinetic parameters were generated via noncompartmental and compartmental analyses. Each horse was monitored via physical and lameness examination and ACJ synovial fluid analysis before injection and at days 1, 2, 3, and 7. Lameness was not observed. Mean ± SD synovial fluid WBC count increased at day 1 (exercised, 721 ± 234 cells/μL; nonexercised, 948 ± 223 cells/μL), but returned to baseline at days 3 and 7 Mean time to maximum plasma radioactivity was earlier in the exercised group (16.00 ± 2.35 minutes) than the nonexercised group (43.75 ± 3.64 minutes). Linear regression of the scintigraphic radioactivity-time curves revealed a greater negative slope in the exercised group within the first 25 minutes. There was no difference in absorption or elimination rate constants in a 2-compartment model. IA injection of (99m)Tc-MDP was safe and effective for evaluating synovial solute distribution. Exercise significantly increased early transfer of (99m)Tc-MDP from the ACJ into plasma, although absorption and elimination rate constants were not affected. Exercise may affect synovial clearance and withdrawal times of medications administered IA.

  17. Effects of positive expiratory pressure on pulmonary clearance of aerosolized technetium-99m-labeled diethylenetriaminepentaacetic acid in healthy individuals

    PubMed Central

    de Albuquerque, Isabella Martins; Cardoso, Dannuey Machado; Masiero, Paulo Ricardo; Paiva, Dulciane Nunes; Resqueti, Vanessa Regiane; Fregonezi, Guilherme Augusto de Freitas; Menna-Barreto, Sérgio Saldanha

    2016-01-01

    ABSTRACT Objective: To evaluate the effects of positive expiratory pressure (PEP) on pulmonary epithelial membrane permeability in healthy subjects. Methods: We evaluated a cohort of 30 healthy subjects (15 males and 15 females) with a mean age of 28.3 ± 5.4 years, a mean FEV1/FVC ratio of 0.89 ± 0.14, and a mean FEV1 of 98.5 ± 13.1% of predicted. Subjects underwent technetium-99m-labeled diethylenetriaminepentaacetic acid (99mTc-DTPA) radioaerosol inhalation lung scintigraphy in two stages: during spontaneous breathing; and while breathing through a PEP mask at one of three PEP levels-10 cmH2O (n = 10), 15 cmH2O (n = 10), and 20 cmH2O (n = 10). The 99mTc-DTPA was nebulized for 3 min, and its clearance was recorded by scintigraphy over a 30-min period during spontaneous breathing and over a 30-min period during breathing through a PEP mask. Results: The pulmonary clearance of 99mTc-DTPA was significantly shorter when PEP was applied-at 10 cmH2O (p = 0.044), 15 cmH2O (p = 0.044), and 20 cmH2O (p = 0.004)-in comparison with that observed during spontaneous breathing. Conclusions: Our findings indicate that PEP, at the levels tested, is able to induce an increase in pulmonary epithelial membrane permeability and lung volume in healthy subjects. PMID:28117469

  18. Assessment of the direct cyclotron production of (99m)Tc: An approach to crisis management of (99m)Tc shortage.

    PubMed

    Rovais, Mohammad Reza Aboudzadeh; Aardaneh, Khosro; Aslani, Gholamreza; Rahiminejad, Ali; Yousefi, Kamran; Boulouri, Fatemeh

    2016-06-01

    Nowadays, the cyclotron production of technetium-99m ((99m)Tc) has been increased, due to the worldwide (99m)Tc generator shortage. In the present work, an improved strategy for the production of (99m)Tc, using the proton irradiation of the enriched (100)Mo was developed. The performance of this method in terms of the production yield, chemical purity, radiochemical purity, as well as radionuclide purity was evaluated. The average production yield was measured to be 356MBqμA(-1)h(-1). A good agreement was found between the calculated production yield and the experimental one. The radiochemical separation and total recovery yields of (99m)Tc were 92% and 69%, respectively. The radiochemical and the radionuclide purities of the (99m)Tc were 99% and >99.99% at the end of purification, respectively. The results of quality control tests (QC) support the concept that cyclotron-produced (99m)Tc is suitable for preparation of USP-compliant. Copyright © 2016 Elsevier Ltd. All rights reserved.

  19. Toward hypoxia-selective rhenium and technetium tricarbonyl complexes.

    PubMed

    North, Andrea J; Hayne, David J; Schieber, Christine; Price, Katherine; White, Anthony R; Crouch, Peter J; Rigopoulos, Angela; O'Keefe, Graeme J; Tochon-Danguy, Henri; Scott, Andrew M; White, Jonathan M; Ackermann, Uwe; Donnelly, Paul S

    2015-10-05

    With the aim of preparing hypoxia-selective imaging and therapeutic agents, technetium(I) and rhenium(I) tricarbonyl complexes with pyridylhydrazone, dipyridylamine, and pyridylaminocarboxylate ligands containing nitrobenzyl or nitroimidazole functional groups have been prepared. The rhenium tricarbonyl complexes were synthesized with short reaction times using microwave irradiation. Rhenium tricarbonyl complexes with deprotonated p-nitrophenyl pyridylhydrazone ligands are luminescent, and this has been used to track their uptake in HeLa cells using confocal fluorescent microscopy. Selected rhenium tricarbonyl complexes displayed higher uptake in hypoxic cells when compared to normoxic cells. A (99m)Tc tricarbonyl complex with a dipyridylamine ligand bearing a nitroimidazole functional group is stable in human serum and was shown to localize in a human renal cell carcinoma (RCC; SK-RC-52) tumor in a mouse.

  20. /sup 99m/Tc-fibrinogen scanning in adult respiratory distress syndrome

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Quinn, D.A.; Carvalho, A.C.; Geller, E.

    1987-01-01

    Fibrin is often seen occluding the lung vessels of patients dying from ARDS and is surrounded by regions of lung necrosis. To learn if we could observe increased or focal fibrin deposition and assess the kinetics of plasma fibrinogen turnover during severe acute respiratory failure, we injected technetium 99m-labeled human purified fibrinogen (Tc-HF) and used gamma camera scanning for as long as 12 h in 13 sequential patients as soon as possible after ICU admission. The fibrinogen uptake rates were determined by calculating the lung:heart radioactivity ratios at each time point. Slopes of the lung:heart ratio versus time were comparedmore » between ARDS and mild acute respiratory failure (ARF). The slope of the lung:heart Tc-HF ratio of the 9 patients with ARDS (2.9 +/- 0.4 units) was markedly higher (p less than 0.02) than the slope of the 4 patients with mild ARF (1.1 +/- 0.4) and the 3 patients studied 5 to 9 months after recovery from respiratory failure (0.7 +/- 0.07). In the 1 patient with ARDS and the 2 patients with mild ARF studied both during acute lung injury and after recovery, the lung:heart Tc-HF ratio had decreased at recovery. To compare the pulmonary uptake of Tc-HF to /sup 99m/Tc-labeled human serum albumin (Tc-HSA), 5 patients were injected with 10 mCi of Tc-HSA, and scanning of the thorax was performed with a similar sequential imaging protocol 24 h after conclusion of the Tc-HF study.« less

  1. Immobilization and Limited Reoxidation of Technetium-99 by Fe(II)-Goethite

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Um, Wooyong; Chang, Hyun-shik; Icenhower, Jonathan P.

    2010-09-30

    This report summarizes the methodology used to test the sequestration of technetium-99 present in both deionized water and simulated Hanford Tank Waste Treatment and Immobilization Plant waste solutions.

  2. Techniques for Loading Technetium-99m and Rhenium-186/188 Radionuclides into Preformed Liposomes for Diagnostic Imaging and Radionuclide Therapy.

    PubMed

    Goins, Beth; Bao, Ande; Phillips, William T

    2017-01-01

    Liposomes can serve as carriers of radionuclides for diagnostic imaging and therapeutic applications. Herein, procedures are outlined for radiolabeling liposomes with the gamma-emitting radionuclide, technetium-99m ( 99m Tc), for noninvasive detection of disease and for monitoring the pharmacokinetics and biodistribution of liposomal drugs, and/or with therapeutic beta-emitting radionuclides, rhenium-186/188 ( 186/188 Re), for radionuclide therapy. These efficient and practical liposome radiolabeling methods use a post-labeling mechanism to load 99m Tc or 186/188 Re into preformed liposomes prepared in advance of the labeling procedure. For all liposome radiolabeling methods described, a lipophilic chelator is used to transport 99m Tc or 186/188 Re across the lipid bilayer of the preformed liposomes. Once within the liposome interior, the pre-encapsulated glutathione or ammonium sulfate (pH) gradient provides for stable entrapment of the 99m Tc and 186/188 Re within the liposomes. In the first method, 99m Tc is transported across the lipid bilayer by the lipophilic chelator, hexamethylpropyleneamine oxime (HMPAO) and 99m Tc-HMPAO becomes trapped by interaction with the pre-encapsulated glutathione within the liposomes. In the second method, 99m Tc or 186/188 Re is transported across the lipid bilayer by the lipophilic chelator, N,N-bis(2-mercaptoethyl)-N',N'-diethylethylenediamine (BMEDA), and 99m Tc-BMEDA or 186/188 Re-BMEDA becomes trapped by interaction with pre-encapsulated glutathione within the liposomes. In the third method, an ammonium sulfate (pH) gradient loading technique is employed using liposomes with an extraliposomal pH of 7.4 and an interior pH of 5.1. BMEDA, which is lipophilic at pH 7.4, serves as a lipophilic chelator for 99m Tc or 186/188 Re to transport the radionuclides across the lipid bilayer. Once within the more acidic liposome interior, 99m Tc/ 186/188 Re-BMEDA complex becomes protonated and more hydrophilic, which results in stable

  3. Clinical application of calculated split renal volume using computed tomography-based renal volumetry after partial nephrectomy: Correlation with technetium-99m dimercaptosuccinic acid renal scan data.

    PubMed

    Lee, Chan Ho; Park, Young Joo; Ku, Ja Yoon; Ha, Hong Koo

    2017-06-01

    To evaluate the clinical application of computed tomography-based measurement of renal cortical volume and split renal volume as a single tool to assess the anatomy and renal function in patients with renal tumors before and after partial nephrectomy, and to compare the findings with technetium-99m dimercaptosuccinic acid renal scan. The data of 51 patients with a unilateral renal tumor managed by partial nephrectomy were retrospectively analyzed. The renal cortical volume of tumor-bearing and contralateral kidneys was measured using ImageJ software. Split estimated glomerular filtration rate and split renal volume calculated using this renal cortical volume were compared with the split renal function measured with technetium-99m dimercaptosuccinic acid renal scan. A strong correlation between split renal function and split renal volume of the tumor-bearing kidney was observed before and after surgery (r = 0.89, P < 0.001 and r = 0.94, P < 0.001). The preoperative and postoperative split estimated glomerular filtration rate of the operated kidney showed a moderate correlation with split renal function (r = 0.39, P = 0.004 and r = 0.49, P < 0.001). The correlation between reductions in split renal function and split renal volume of the operated kidney (r = 0.87, P < 0.001) was stronger than that between split renal function and percent reduction in split estimated glomerular filtration rate (r = 0.64, P < 0.001). The split renal volume calculated using computed tomography-based renal volumetry had a strong correlation with the split renal function measured using technetium-99m dimercaptosuccinic acid renal scan. Computed tomography-based split renal volume measurement before and after partial nephrectomy can be used as a single modality for anatomical and functional assessment of the tumor-bearing kidney. © 2017 The Japanese Urological Association.

  4. p-Tertbutylcalix[4]arene nanoemulsion: preparation, characterization and comparative evaluation of its decontamination efficacy against Technetium-99m, Iodine-131 and Thallium-201.

    PubMed

    Rana, Sudha; Sharma, Navneet; Ojha, Himanshu; Shivkumar, Hosakote Gurumalappa; Sultana, Sarwat; Sharma, Rakesh Kumar

    2014-05-01

    This study aimed to develop p-tertbutylcalix[4]arene o/w nanoemulsion for decontamination of radioisotopes from skin. Formulation was characterized using dynamic light scattering (DLS), transmission electron microscopy (TEM), multi-photon confocal microscopy techniques and in vitro dissolution studies. In vivo evaluation of nano-emulsion was done using nuclear medicine technique. Stability studies and dermal toxicity studies were also carried out. Comparative decontamination efficacy (DE) studies were performed on synthetic human tissue equivalent material and Sprague Dawley rat against three commonly used medical radioisotopes, i.e., Technetium-99m ((99m)Tc), Iodine-131 ((131)I) and Thallium-201 ((201)Tl). Decontamination was performed using cotton swabs soaked in nanoemulsion at different time intervals of contaminants exposure. Whole body imaging and static counts were recorded using gamma camera before and after each decontamination attempt data was analyzed using one way analysis of variance (ANOVA) and found to be statistically significant (p<0.05). DE of the nanoemulsion loaded with p-tertbutylcalix[4]arene was observed to be 88±5%, 90±3% and 89±3% for (99m)Tc, (131)I and (201)Tl respectively. Dermal toxicity studies revealed no significant differences between treated and control animals. Skin histopathology slides with and without API (Active pharmaceutical ingredients) also found to be comparable. p-Tertbutylcalix[4]arene loaded nanoemulsion shows great promise for skin decontamination against broad ranges of radiological contaminants besides being stable and safe. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Kinetic sensitivity of a receptor-binding radiopharmaceutical: Technetium-99m galactosyl-neoglycoalbumin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vera, D.R.; Woodle, E.S.; Stadalnik, R.C.

    1989-09-01

    Kinetic sensitivity is the ability of a physiochemical parameter to alter the time-activity curve of a radiotracer. The kinetic sensitivity of liver and blood time-activity data resulting from a single bolus injection of ({sup 99m}Tc)galactosyl-neoglycoalbumin (( Tc)NGA) into healthy pigs was examined. Three parameters, hepatic plasma flow scaled as flow per plasma volume, ligand-receptor affinity, and total receptor concentration, were tested using (Tc)NGA injections of various molar doses and affinities. Simultaneous measurements of plasma volume (iodine-125 human serum albumin dilution), and hepatic plasma flow (indocyanine green extraction) were performed during 12 (Tc)NGA studies. Paired data sets demonstrated differences (P(chi v2)more » less than 0.01) in liver and blood time-activity curves in response to changes in each of the tested parameters. We conclude that the (Tc)NGA radiopharmacokinetic system is therefore sensitive to hepatic plasma flow, ligand-receptor affinity, and receptor concentration. In vivo demonstration of kinetic sensitivity permits delineation of the physiologic parameters that determine the biodistribution of a radiopharmaceutical. This delineation is a prerequisite to a valid analytic assessment of receptor biochemistry via kinetic modeling.« less

  6. Investigating the Role of Global Histogram Equalization Technique for 99mTechnetium-Methylene diphosphonate Bone Scan Image Enhancement

    PubMed Central

    Pandey, Anil Kumar; Sharma, Param Dev; Dheer, Pankaj; Parida, Girish Kumar; Goyal, Harish; Patel, Chetan; Bal, Chandrashekhar; Kumar, Rakesh

    2017-01-01

    Purpose of the Study: 99mTechnetium-methylene diphosphonate (99mTc-MDP) bone scan images have limited number of counts per pixel, and hence, they have inferior image quality compared to X-rays. Theoretically, global histogram equalization (GHE) technique can improve the contrast of a given image though practical benefits of doing so have only limited acceptance. In this study, we have investigated the effect of GHE technique for 99mTc-MDP-bone scan images. Materials and Methods: A set of 89 low contrast 99mTc-MDP whole-body bone scan images were included in this study. These images were acquired with parallel hole collimation on Symbia E gamma camera. The images were then processed with histogram equalization technique. The image quality of input and processed images were reviewed by two nuclear medicine physicians on a 5-point scale where score of 1 is for very poor and 5 is for the best image quality. A statistical test was applied to find the significance of difference between the mean scores assigned to input and processed images. Results: This technique improves the contrast of the images; however, oversaturation was noticed in the processed images. Student's t-test was applied, and a statistically significant difference in the input and processed image quality was found at P < 0.001 (with α = 0.05). However, further improvement in image quality is needed as per requirements of nuclear medicine physicians. Conclusion: GHE techniques can be used on low contrast bone scan images. In some of the cases, a histogram equalization technique in combination with some other postprocessing technique is useful. PMID:29142344

  7. Liver Function Assessment Using Technetium 99m-Galactosyl Single-Photon Emission Computed Tomography/CT Fusion Imaging: A Prospective Trial.

    PubMed

    Okabayashi, Takehiro; Shima, Yasuo; Morita, Sojiro; Shimada, Yasuhiro; Sumiyoshi, Tatsuaki; Sui, Kenta; Iwata, Jun; Iiyama, Tatsuo

    2017-12-01

    The prediction of postoperative liver function remains a largely subjective practice based on CT volumetric analysis. However, future liver volume after a hepatectomy is not the only factor that contributes to postoperative liver function and outcomes. In this prospective trial, 185 consecutive patients who underwent liver operations between 2014 and 2015 were studied. Volumetric and functional rates of remnant liver were measured using technetium 99m-galactosyl human serum albumin single-photon emission computed tomography/CT fusion imaging to evaluate post-hepatectomy remnant liver function. Remnant indocyanine green clearance rate using galactosyl (KGSA) (KGSA × functional rate) was used to predict future remnant liver function. Hepatectomy was considered safe for patients with remnant KGSA values ≥0.05, and the primary end point was to determine the accuracy and reliability of this criteria. The prediction of the 90-day major complication and mortality rates was assessed. Median hospital stay was 9 days and median ICU stay was 1 day, with only 1 in-hospital death (90-day mortality rate 0.5%). Overall morbidity rate evaluated according to the Clavien-Dindo classification was 9%. For post-hepatectomy liver failure definitions, the International Study Group of Liver Surgery definition was fulfilled in 14 patients (8%), with the majority being grade B (50%), compared with 2 patients (1%) fulfilling the "50-50" criteria, and 0 patients (0%) fulfilling the Peak Bili >7 criteria. Results of this study showed that remnant KGSA provided information that allowed us to predict remnant liver function. This information will be important for surgeons when deciding on a treatment plan for patients with liver diseases. (ClinicalTrials.gov ID: NCT02013895). Copyright © 2017 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Techniques for loading technetium-99m and rhenium-186/188 radionuclides into pre-formed liposomes for diagnostic imaging and radionuclide therapy.

    PubMed

    Goins, Beth; Bao, Ande; Phillips, William T

    2010-01-01

    Liposomes can serve as carriers of radionuclides for diagnostic imaging and therapeutic applications. Herein, procedures are outlined for radiolabeling liposomes with the gamma-emitting radionuclide, technetium-99m ((99m)Tc), for non-invasive detection of disease and for monitoring the pharmacokinetics and biodistribution of liposomal drugs, and/or with therapeutic beta-emitting radionuclides, rhenium-186/188 ((186/188)Re), for radionuclide therapy. These efficient and practical liposome radiolabeling methods use a post-labeling mechanism to load (99m)Tc or (186/188)Re into pre-formed liposomes prepared in advance of the labeling procedure. For all liposome radiolabeling methods described, a lipophilic chelator is used to transport (99m)Tc or (186/188)Re across the lipid bilayer of the pre-formed liposomes. Once within the liposome interior, the pre-encapsulated glutathione or ammonium sulfate (pH) gradient provides for stable entrapment of the (99m)Tc and (186/188)Re within the liposomes. In the first method, (99m)Tc is transported across the lipid bilayer by the lipophilic chelator, hexamethylpropyleneamine oxime (HMPAO) and (99m)Tc-HMPAO becomes trapped by interaction with the pre-encapsulated glutathione within the liposomes. In the second method, (99m)Tc or (186/188)Re is transported across the lipid bilayer by the lipophilic chelator, N,N-bis(2-mercaptoethyl)-N',N'-diethylethylenediamine (BMEDA), and (99m)Tc-BMEDA or (186/188)Re-BMEDA becomes trapped by interaction with pre-encapsulated glutathione within the liposomes. In the third method, an ammonium sulfate (pH) gradient loading technique is employed using liposomes with an extraliposomal pH of 7.4 and an interior pH of 5.1. BMEDA, which is lipophilic at pH 7.4, serves as a lipophilic chelator for (99m)Tc or (186/188)Re to transport the radionuclides across the lipid bilayer. Once within the more acidic liposome interior, (99m)Tc/(186/188)Re-BMEDA complex becomes protonated and more hydrophilic, which

  9. Applications and interpretation of krypton 81m ventilation/technetium 99m macroaggregate perfusion lung scanning in childhood

    NASA Astrophysics Data System (ADS)

    Davies, Hugh Trevor Frimston

    Radionuclide ventilation perfusion lung scans now play an important part in the investigation of paediatric lung disease, providing a safe, noninvasive assessment of regional lung function in children with suspected pulmonary disease. In paediatric practice the most suitable radionuclides are Krypton 81m (Kr81m) and Technetium 99m (Tc99m), which are jointly used in the Kr81m ventilation/Tc99m macroaggregate perfusion lung scan (V/Q lung scan). The Kr81m ventilation scan involves a low radiation dose, requires little or no subject cooperation and because of the very short half life of Kr81m (13 seconds) the steady state image acquired during continuous inhalation of the radionuclide is considered to reflect regional distribution of ventilation. It is now the most important noninvasive method available for the investigation of the regional abnormalities of ventilation characteristic of many congenital and acquired paediatric respiratory diseases, such as diaphragmatic hernia, pulmonary sequestration, bronchopulmonary dysplasia, foreign body inhalation and bronchiectasis. It improves diagnostic accuracy, aids clinical decision making and is used to monitor the progress of disease and response to therapy. Theoretical analysis of the steady state Kr81m ventilation image suggests that it may only reflect regional ventilation when specific ventilation (ventilation per unit volume of lung) is within or below the normal adult range (1-3 L/L/min). At higher values such as those seen in neonates and infants (8-15 L/L/min) Kr81m activity may reflect regional lung volume rather than ventilation, a conclusion supported by the studies of Ciofetta et al. There is some controversy on this issue as animal studies have demonstrated that the Kr81m image reflects ventilation over a much wider range of specific ventilation (up to 13 L/L/min). A clinical study of sick infants and very young children is in agreement with this animal work and suggests that the steady state Kr81m image

  10. Radiosynthesis and Biodistribution of 99mTc-Metronidazole as an Escherichia coli Infection Imaging Radiopharmaceutical.

    PubMed

    Iqbal, Anam; Naqvi, Syed Ali Raza; Rasheed, Rashid; Mansha, Asim; Ahmad, Matloob; Zahoor, Ameer Fawad

    2018-05-01

    Bacterial infection poses life-threatening challenge to humanity and stimulates to the researchers for developing better diagnostic and therapeutic agents complying with existing theranostic techniques. Nuclear medicine technique helps to visualize hard-to-diagnose deep-seated bacterial infections using radionuclide-labeled tracer agents. Metronidazole is an antiprotozoal antibiotic that serves as a preeminent anaerobic chemotherapeutic agent. The aim of this study was to develop technetium-99m-labeled metronidazole radiotracer for the detection of deep-seated bacterial infections. Radiosynthesis of 99m Tc-metronidazole was carried by reacting reduced technetium-99m and metronidazole at neutral pH for 30 min. The stannous chloride dihydrate was used as the reducing agent. At optimum radiolabeling conditions, ~ 94% radiochemical was obtained. Quality control analysis was carried out with a chromatographic paper and instant thin-layer chromatographic analysis. The biodistribution study of radiochemical was performed using Escherichia coli bacterial infection-induced rat model. The scintigraphic study was performed using E. coli bacterial infection-induced rabbit model. The results showed promising accumulation at the site of infection and its rapid clearance from the body. The tracer showed target-to-non-target ratio 5.57 ± 0.04 at 1 h post-injection. The results showed that 99m Tc-MNZ has promising potential to accumulate at E. coli bacterial infection that can be used for E. coli infection imaging.

  11. Calculation of therapeutic activity of radioiodine in Graves' disease by means of Marinelli's formula, using technetium (99mTc) scintigraphy.

    PubMed

    Szumowski, Piotr; Mojsak, Małgorzata; Abdelrazek, Saeid; Sykała, Monika; Amelian-Fiłonowicz, Anna; Jurgilewicz, Dorota; Myśliwiec, Janusz

    2016-12-01

    The therapeutic activity of 131 I administered to patients with Graves' disease can be calculated by means of Marinelli's formula. The thyroidal iodine uptake ( 131 IU max ) needed for the calculation is usually determined with the use of 131 I. The purpose of the paper was to estimate 131 IU max on the basis of technetium uptake in the thyroid at 20 min ( 99m TcU 20min ). Eighty patients suffering from Graves' disease were qualified for radioiodine therapy with measurement of fT 4 , fT 3 , thyroid-stimulating hormone and its receptor (TRAb). Prior to the treatment, all the patients were euthyroid. 131 IU max for each patient was determined according to the levels of 131 I after 24 h ( 131 IU 24h ), while effective half-life (T eff ) according to the measurements of 131 IU 24h and 131 I uptake after 48 h ( 131 IU 48h ). Additionally, on the day before measuring 131 IU 24h , 99m TcU 20min was calculated for each patient. It was demonstrated that there existed a correlation, with statistical significance at p < 0.05, between the following pairs of values: TRAb and 131 IU 24h , TRAb and 99m TcU 20min , and 99m TcU 20min and 131 IU 24h . The interdependence between 131 IU 24h and 99m TcU 20min at the level of significance p < 0.05 is described by the following algorithms: 131 IU 24h  = 17.72 × ln ( 99m TcU 20min ) + 30.485, if TRAb < 10 IU/ml, and 131 IU 24h  = 18.03 × ln ( 99m TcU 20min ) + 38.726, if TRAb > 10 IU/ml. It is possible to predict thyroid iodine uptake 131 IU 24h in Graves' disease on the basis of measuring the uptake of 99m TcU 20min . This shortens the time necessary for diagnosis and enables the calculation of 131 I activity using Marinelli's formula.

  12. Pharmacokinetics of 99mTc-MAA- and 99mTc-HSA-Microspheres Used in Preradioembolization Dosimetry: Influence on the Liver-Lung Shunt.

    PubMed

    Grosser, Oliver S; Ruf, Juri; Kupitz, Dennis; Pethe, Annette; Ulrich, Gerhard; Genseke, Philipp; Mohnike, Konrad; Pech, Maciej; Richter, Wolf S; Ricke, Jens; Amthauer, Holger

    2016-06-01

    Perfusion scintigraphy using (99m)Tc-labeled albumin aggregates is mandatory before hepatic radioembolization with (90)Y-microspheres. As part of a prospective trial, the intrahepatic and intrapulmonary stability of 2 albumin compounds, (99m)Tc-MAA (macroaggregated serum albumin [MAA]) and (99m)Tc-HSA (human serum albumin [HSA]), was assessed. In 24 patients with metastatic colorectal cancer, biodistribution (liver, lung) and liver-lung shunt (LLS) of both tracers (12 patients each) were assessed by sequential planar scintigraphy (1, 5, and 24 h after injection). Liver uptake of both albumin compounds decreased differently. Although initial LLSs at 1 h after injection were similar in both groups, MAA-LLS increased significantly from 1 (3.9%) to 5 h (7.7%) and 24 h (9.9%) after injection, respectively. HSA-LLS did not change significantly (1 to 5 h), indicating a steady state of pulmonary and intrahepatic degradation. Compared with (99m)Tc-MAA-microspheres, (99m)Tc-HSA-microspheres are likely more resistant to degradation over time, allowing a reliable LLS determination even at later time points. © 2016 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  13. Technetium-99m sestamibi scintimammography complements mammography in the detection of breast cancer.

    PubMed

    Krishnaiah, Gayathri; Sher-Ahmed, Arifa; Ugwu-Dike, Martins; Regan, Patricia; Singer, John; Totoonchie, Adil; Spiegler, Ethan; Sardi, Armando

    2003-01-01

    Mammography remains the technique of choice for the detection of early breast cancer. The sensitivity of mammography is 85%, but is decreased in patients with dense breasts. Sestamibi scintimammography (SCM) has been suggested as an adjunctive modality to improve the detection of breast cancer. We conducted a study to determine the impact of SCM in patient management. A prospective study was conducted in 95 patients presenting with palpable masses and/or abnormal mammography scheduled for biopsy. Injection of 20-30 mCi of technetium-99m (Tc-99m) sestamibi into a pedal vein was performed. Ten-minute images of the breast and axilla were obtained in multiple projections. The mammography and SCM were correlated with pathology and clinical findings. The median age was 44 years (range 28-86 years). The total number of lesions was 104, as eight patients had bilateral lesions and one patient had two lesions in the same breast. Fifty-nine patients presented with palpable lesions and 45 patients with nonpalpable lesions (42 with abnormal mammography only and 3 with nipple discharge). A comparison of sensitivity, specificity, positive and negative predictive values, and overall accuracy of SCM and mammography were performed. The sensitivity and specificity for SCM were 83% and 83%, respectively, and for mammography were 65%, and 72%, respectively. The sensitivity and specificity for combined SCM and mammography were 87% and 94%, respectively. The p-value for mammography versus combined SCM and mammography was 0.0003 and that for SCM versus SCM and mammography was 0.0098. There were 80 (77%) benign and 24 (23%) malignant lesions. Of the 24 malignancies, SCM missed six (25%), versus eight (33%) by mammography. In two patients (9%) SCM detected malignancy in the breast that was not visualized by mammography or found on clinical examination. Sestamibi SCM improves the sensitivity of mammography and it detects up to 9% of malignancies not detected by mammography or clinical

  14. Sectorial technetium-99m-dimercaptosuccinic acid scintigraphy for monitoring the effect of extracorporeal piezoelectric lithotripsy for calyceal calculi on regional renal function.

    PubMed

    Al-Tawheed, A; Al-Awadi, K A; Kehinde, E O; Loutfi, I; Abdul-Haleem, H; Al-Mohannadi, S

    2003-01-01

    To apply a semiquantitative method for analysis of technetium-99m-dimercaptosuccinic acid ((99m)Tc-DMSA) renal scintigraphy for monitoring the effect of extracorporeal piezoelectric lithotripsy (EPL) in patients with calyceal stones on regional kidney function and to check whether EPL had caused any deleterious effect on the target calyceal renal parenchymal function. Forty patients (mean age 35 years) suffering from calyceal stones documented by abdominal plain radiography, intravenous urogram or abdominal ultrasound were studied. All patients were treated by EPL. (99m)Tc-DMSA scan was performed before and 4 weeks after EPL. Sector analysis involved calculation of the relative function of the target calyx to the function of the ipsilateral kidney and the relative function of the treated kidney to global renal function. The stone sizes were 6-11 mm in diameter and 11 were located in the upper, 13 in the middle and 16 in the lower calyx. After EPL, the overall stone clearance rate was 85% (100% for calculi in the upper and middle calyces, 62% for lower calyces). The sector analysis did not show statistically significant change of the relative regional (calyceal) or whole kidney function between the pre- and post-EPL (99m)Tc-DMSA scans. Using sector analysis, EPL appeared to be a safe modality and its usage was not associated with any untoward effect on calyceal or whole kidney function. Sector analysis of (99m)Tc-DMSA renal scan is a simple semiquantitative method for monitoring regional changes of kidney function after EPL for treatment of calyceal stone. Copyright 2003 S. Karger AG, Basel

  15. Axillary lymph node uptake of technetium-99m-MDP

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ongseng, F.; Goldfarb, C.R.; Finestone, H.

    We sought to determine the frequency and significance of axillary lymph node visualization on bone scans performed with diphosphonates. Consecutive {sup 99m}Tc-methylene diphosphonate ({sup 99m}Tc-MDP) bone scans (2435) were inspected for axillary soft-tissue uptake. In positive cases, the results of physical examination, correlative imaging studies and serial bone scans were recorded, as was the site of venipuncture. Forty-eight studies (2%) showed axillary uptake ipsilateral to the injection site. Extravasation of tracer, documented by focal activity near the injection site, was present in every case. There was no association with axillary adenopathy, mass, induration of radiographically visible calcification. On some images,more » foci adjacent to the axilla were superimposed on the rib, scapula, or humerus. The bone-to-background ratio was frequently reduced; repeat imaging after 1-2 hr usually improved osseous detail. Ipsilateral axillary lymph node visualization due to extravasation of {sup 99m}Tc-MDP is frequently associated with additional foci superimposed on osseous structures simulating pathology. Delayed skeletal uptake is common in such cases and necessitates a greater time interval between injection and imaging. 7 refs., 3 figs.« less

  16. Detection of bacterial infection by a technetium-99m-labeled peptidoglycan aptamer.

    PubMed

    Ferreira, Iêda Mendes; de Sousa Lacerda, Camila Maria; Dos Santos, Sara Roberta; de Barros, André Luís Branco; Fernandes, Simone Odília; Cardoso, Valbert Nascimento; de Andrade, Antero Silva Ribeiro

    2017-09-01

    Nuclear medicine clinicians are still waiting for the optimal scintigraphic imaging agents capable of distinguishing between infection and inflammation, and between fungal and bacterial infections. Aptamers have several properties that make them suitable for molecular imaging. In the present study, a peptidoglycan aptamer (Antibac1) was labeled with 99m Tc and evaluated by biodistribution studies and scintigraphic imaging in infection-bearing mice. Labeling with 99m Tc was performed by the direct method and the complex stability was evaluated in saline, plasma and in the molar excess of cysteine. The biodistribution and scintigraphic imaging studies with the 99m Tc-Antibac1 were carried out in two different experimental infection models: Bacterial-infected mice (S. aureus) and fungal-infected mice (C. albicans). A 99m Tc radiolabeled library, consisting of oligonucleotides with random sequences, was used as a control for both models. Radiolabeling yields were superior to 90% and 99m Tc-Antibac1 was highly stable in presence of saline, plasma, and cysteine up to 6h. Scintigraphic images of S. aureus infected mice at 1.5 and 3.0h after 99m Tc-Antibac1 injection showed target to non-target ratios of 4.7±0.9 and 4.6±0.1, respectively. These values were statistically higher than those achieved for the 99m Tc-library at the same time frames (1.6±0.4 and 1.7±0.4, respectively). Noteworthy, 99m Tc-Antibac1 and 99m Tc-library showed similar low target to non-target ratios in the fungal-infected model: 2.0±0.3 and 2.0±0.6for 99m Tc-Antibac1 and 2.1±0.3 and 1.9 ± 0.6 for 99m Tc-library, at the same times. These findings suggest that the 99m Tc-Antibac1 is a feasible imaging probe to identify a bacterial infection focus. In addition, this radiolabeled aptamer seems to be suitable in distinguishing between bacterial and fungal infection. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  17. Technetium-99m thyroid scan; does it have a diagnostic aid in sub-clinical auto-immune thyroid disease in systemic lupus erythematosus patients?

    PubMed

    Amin, A; Alkemary, A; Abdo, M; Salama, M

    2016-02-01

    Technetium-99m (Tc-99m) thyroid scintigraphy is a well known diagnostic tool that shows the entire gland in a single image. We aimed to evaluate its additive diagnostic value in subclinical autoimmune thyroid disease (S-AITD) in systemic lupus erythematosus (SLE) patients. We investigated 100 systemic lupus erythematosus (SLE) patients without overt thyroid involvement (eight men and 92 women; mean age 40±6.5 years) and 50 age and sex matched controls. All were subjected to thyroid evaluation using anti-thyroglobulin (anti-TG) and anti-thyroid peroxidase (anti-TPO) antibodies; hormones (FT3; FT4 and TSH) and Tc-99m thyroid scintigraphy. 14/100 (14%) and none (0%) were positive for S-AITD in SLE and control groups, respectively (P = 0.0001). They were classified by thyroid scintigraphy and hormonal profile into 2/14 Hashimoto; 10/14 atrophic thyroiditis and 2/14 Graves' disease. Anti-TPO was elevated in 12 SLE cases, while anti-TG was elevated in only 2/14 (P = 0.0001). Thyroid scintigraphy showed statistically significant associations with FT4, TSH and anti-TPO. Tc-99m thyroid scintigraphy may have an additional diagnostic role in S-AITD among SLE patients, with an impact on patient management. This potential needs to be further evaluated in a larger series on a multicenter basis. © The Author(s) 2015.

  18. Differences in the intracellular processing of the radiolabel following the uptake of iodine-125- and technetium-99m-neogalactosyl albumin by the isolated perfused rat liver

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gore, S.; Morris, A.I.; Gilmore, I.T.

    1991-03-01

    Neogalactosyl albumin (NGA) is a synthetic ligand to the asialoglycoprotein receptor (hepatic binding protein), which has been proposed as a useful receptor binding radiopharmaceutical for the noninvasive assessment of liver function. We have compared the uptake and intracellular processing of iodine-125- (125I) and technetium-99m- ({sup 99m}Tc) NGA following its administration as a 1-min pulse (147 pmol) to the isolated perfused rat liver. Approximately 40% of a pulse of either {sup 125}I- or {sup 99m}Tc-NGA were taken up first pass by the liver. Of the {sup 125}I taken up by the liver, 82% was released after 15-20 min at the sinusoidalmore » pole of the hepatocyte, predominantly as small molecular weight metabolites. A further 8% of the {sup 125}I-associated radioactivity was secreted as intact NGA into bile by the non-lysosomal (direct) pathway while 6% remained in the liver 1 hr after the pulse. In contrast, of the {sup 99m}Tc taken up by the liver, only 4% reappeared in the perfusate while 40% was secreted into bile by the lysosomal (indirect) pathway and 55% remained in the liver 1 hr after the pulse. Since labeled metabolites of {sup 99m}Tc-NGA do not appear in plasma, this permits kinetic modeling with {sup 99m}Tc-NGA without correction for labeled metabolites. Thus, {sup 99m}Tc-NGA is an excellent candidate as a receptor-binding radiopharmaceutical.« less

  19. Technetium tc 99m-labeled red blood cells in the preoperative diagnosis of cavernous hemangioma and other vascular orbital tumors.

    PubMed

    Polito, Ennio; Burroni, Luca; Pichierri, Patrizia; Loffredo, Antonio; Vattimo, Angelo G

    2005-12-01

    To evaluate technetium Tc 99m (99mTc) red blood cell scintigraphy as a diagnostic tool for orbital cavernous hemangioma and to differentiate between orbital masses on the basis of their vascularization. We performed 99mTc red blood cell scintigraphy on 23 patients (8 female and 15 male; mean age, 47 years) affected by an orbital mass previously revealed with computed tomography (CT) and magnetic resonance imaging (MRI) and suggesting cavernous hemangioma. In our diagnosis, we considered the orbital increase delayed uptake with the typical scintigraphic pattern known as perfusion blood pool mismatch. The patients underwent biopsy or surgical treatment with transconjunctival cryosurgical extraction when possible. Single-photon emission tomography (SPET) showed intense focal uptake in the orbit corresponding to radiologic findings in 11 patients who underwent surgical treatment and pathologic evaluation (9 cavernous hemangiomas, 1 hemangiopericytoma, and 1 lymphangioma). Clinical or histologic examination of the remaining 22 patients revealed the presence of 5 lymphoid pseudotumors, 2 lymphomas, 2 pleomorphic adenomas of the lacrimal gland, 1 astrocytoma, 1 ophthalmic vein thrombosis, and 1 orbital varix. The confirmation of the preoperative diagnosis by 99mTc red blood cell scintigraphy shows that this technique is a reliable tool for differentiating cavernous hemangiomas from other orbital masses (sensitivity, 100%; specificity, 86%) when ultrasound, CT, and MRI are not diagnostic. Unfortunately, 99mTc red blood cell scintigraphy results were positive in 1 patient with hemangiopericytoma and 1 patient with lymphangioma, which showed increased uptake in the lesion on SPET images because of the vascular nature of these tumors. Therefore, in these cases, the SPET images have to be integrated with data regarding clinical preoperative evaluation and CT scans or MRI studies. On the basis of our study, a complete diagnostic picture, CT scans or MRI studies, and

  20. In Vivo Imaging and Tracking of Technetium-99m Labeled Bone Marrow Mesenchymal Stem Cells in Equine Tendinopathy

    PubMed Central

    Dudhia, Jayesh; Becerra, Patricia; Valdés, Miguel A.; Neves, Francisco; Hartman, Neil G.; Smith, Roger K.W.

    2015-01-01

    Recent advances in the application of bone marrow mesenchymal stem cells (BMMSC) for the treatment of tendon and ligament injuries in the horse suggest improved outcome measures in both experimental and clinical studies. Although the BMMSC are implanted into the tendon lesion in large numbers (usually 10 - 20 million cells), only a relatively small number survive (<10%) although these can persist for up to 5 months after implantation. This appears to be a common observation in other species where BMMSC have been implanted into other tissues and it is important to understand when this loss occurs, how many survive the initial implantation process and whether the cells are cleared into other organs. Tracking the fate of the cells can be achieved by radiolabeling the BMMSC prior to implantation which allows non-invasive in vivo imaging of cell location and quantification of cell numbers. This protocol describes a cell labeling procedure that uses Technetium-99m (Tc-99m), and tracking of these cells following implantation into injured flexor tendons in horses. Tc-99m is a short-lived (t1/2 of 6.01 hr) isotope that emits gamma rays and can be internalized by cells in the presence of the lipophilic compound hexamethylpropyleneamine oxime (HMPAO). These properties make it ideal for use in nuclear medicine clinics for the diagnosis of many different diseases. The fate of the labeled cells can be followed in the short term (up to 36 hr) by gamma scintigraphy to quantify both the number of cells retained in the lesion and distribution of the cells into lungs, thyroid and other organs. This technique is adapted from the labeling of blood leukocytes and could be utilized to image implanted BMMSC in other organs. PMID:26709915

  1. Increased technetium-99 m hydroxy diphosphonate soft tissue uptake on bone scintigraphy in chronic kidney disease patients with secondary hyperparathyroidism: correlation with hyperphosphataemia.

    PubMed

    Enevoldsen, Lotte Hahn; Heaf, James; Højgaard, Liselotte; Zerahn, Bo; Hasbak, Philip

    2017-03-01

    In bone scan patients with dialysis-treated chronic kidney disease (CKD) and hyperparathyroidism, soft tissue accumulation of technetium-99 m hydroxy/methylene diphosphonate (Tc-99 m-HDP/MDP) has been reported primarily in case reports and usually explained by hypercalcaemia and/or hyperphosphataemia. As human vascular smooth muscle cells produce hydroxyapatite during cell culture with increased phosphate levels and as Tc-99 m-HDP/MDP primarily binds to hydroxyapatite, we hypothesized that soft tissue accumulation would be found in patients with hyperphosphataemia. We identified 63 CKD patients diagnosed with secondary hyperparathyroidism admitted for Tc-99 m-HDP bone scan. Baseline characteristics and mean concentrations of biochemical markers (including P-calcium and P-phosphate) taken 0-3 months prior to the bone scans were collected. Soft tissue uptake was detected on bone scans in 37 of 63 (59%) patients. Primary locations were in the heart (27/37 = 73%), muscles (12/37 = 32%), lung (9/37 = 24%) and gastrointestinal tract (6/37 = 16%), and 13 of 37 (35%) patients had simultaneous uptake in more than one location. Regarding biochemical markers, patients with soft tissue uptake only differed from patients without in terms of plasma phosphate levels (1·95 ± 0·15 (n = 37) versus 1·27 ± 0·08 (n = 26), P = 0·0012). All patients with myocardial uptake (n = 27) had a coronary arteriography-verified history of coronary artery disease (CAD), whereas CAD was only present in six of the 36 patients without myocardial uptake. In conclusion, dialysis-treated CKD patients with secondary hyperparathyroidism have a high incidence of soft tissue uptake, and this finding is strongly correlated with elevated phosphate, but not calcium values. © 2015 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

  2. Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion

    PubMed Central

    Shi, Tujin; Sun, Xuefei; Gao, Yuqian; Fillmore, Thomas L.; Schepmoes, Athena A.; Zhao, Rui; He, Jintang; Moore, Ronald J.; Kagan, Jacob; Rodland, Karin D.; Liu, Tao; Liu, Alvin Y.; Smith, Richard D.; Tang, Keqi; Camp, David G.; Qian, Wei-Jun

    2013-01-01

    We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50–100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion. Limits of quantification (LOQ) at low ng/mL levels with a median coefficient of variation (CV) of ~12% were achieved for proteins spiked into human female serum. PRISM-SRM provided >100-fold improvement in the LOQ when compared to conventional LC-SRM measurements. PRISM-SRM was then applied to measure several low-abundance endogenous serum proteins, including prostate-specific antigen (PSA), in clinical prostate cancer patient sera. PRISM-SRM enabled confident detection of all target endogenous serum proteins except the low pg/mL-level cardiac troponin T. A correlation coefficient >0.99 was observed for PSA between the results from PRISM-SRM and immunoassays. Our results demonstrate that PRISM-SRM can successful quantify low ng/mL proteins in human plasma or serum without depletion. We anticipate broad applications for PRISM-SRM quantification of low-abundance proteins in candidate biomarker verification and systems biology studies. PMID:23763644

  3. Evaluation of hepatic function with (99m)Tc-galactosylated serum albumin scintigraphy in patients with malaria: comparison with (99m)Tc-colloid scintigraphy and liver ultrasonography.

    PubMed

    Lee, Sang-Woo; Lee, Jaetae; Lee, Deog-Young; Chun, Kyung-Ah; Ahn, Byeong-Cheol; Kang, Young-Mo; Lee, Kyubo

    2007-02-01

    Malarial parasites injected by the mosquito rapidly target hepatocytes, and hepatomegaly is commonly observed during the progress of the disease in malaria patients. To evaluate the degree of hepatic damage and functional status of hepatocytes in malaria patients, we performed liver scintigraphy using (99m)Tc-galactosylated serum albumin (GSA) prospectively and the findings were compared with those of (99m)Tc-colloid scintigraphy, ultrasonography and clinical results in the same subject. Eight malaria patients (all male, mean age 22 years) confirmed to be infected with Plasmodium vivax underwent (99m)Tc-GSA liver scintigraphy, followed by liver ultrasonography and (99m)Tc-colloid scintigraphy using phytate within 3 days. For hepatocyte scintigraphy, anterior images of cardiac blood-pool and liver were continuously acquired for 30 min after injection of 185 MBq (99m)Tc-GSA (3 mg). In addition to visual interpretation of the images, quantitative measurement of hepatic function was performed with several functional parameters, such as hepatic uptake index (LHL15), blood clearance index (HH15) and modified receptor index (LHL/HH) calculated from the radioactivity of the liver and heart. (99m)Tc-colloid images were assessed and graded visually. Severity of hepatic dysfunction or reticuloendothelial system activation was classified as normal, mild, moderate and severe on GSA or colloid images. Hepatomegaly was observed in five and splenomegaly in seven of the eight patients. Serum levels of transaminase and alkaline phosphatase were mildly elevated in two. Visual assessment of GSA scintigraphy revealed normal findings in all subjects, except for mild increases in size. The mean values of LHL15, HH15 and LHL/HH were 0.928+/-0.014, 0.537+/-0.031 and 1.732+/-0.106, respectively. They were graded as normal in five, and near-normal to mild dysfunction in three subjects. In contrast, (99m)Tc-colloid scintigraphy revealed abnormal findings in all of the subjects, and graded as

  4. Synthesis and biological assessment of folate-accepted developer (99m)Tc-DTPA-folate-polymer.

    PubMed

    Chen, Fei; Shao, Kejing; Zhu, Bao; Jiang, Mengjun

    2016-05-15

    A novel cancer-targetable folate-poly(2-hydroxyethyl methacrylate) (PFDH) copolymer containing DTPA segment was prepared by conventional chemical synthesis and labeled with (99m)Tc subsequently. The (99m)Tc-labled PFDH could be produced easily with high radiochemical yield of 91% and radiochemical purity of 95%. The LogP octanol-water value for the (99m)Tc-labled PFDH was -2.19 and the radiotracer was stable in phosphate-buffered saline and human serum for 2h (>95% in PBS or ∼90% in human serum). To investigate (99m)Tc-labled PFDH tumor targeting, the in vitro and in vivo stability, cell uptake, in vivo biodistribution, and SPECT imaging were evaluated, respectively. These preliminary results strongly suggest that the novel folate conjugated dendrimer maybe developed to be potential for delivery of therapeutic radionuclides. Copyright © 2016 Elsevier Ltd. All rights reserved.

  5. A prospective evaluation of preoperative localization by technetium-99m sestamibi scintigraphy and ultrasonography in primary hyperparathyroidism.

    PubMed

    Lo, Chung-Yau; Lang, Brian H; Chan, W F; Kung, Annie W C; Lam, Karen S L

    2007-02-01

    Ultrasonography (USG) and technetium-99m sestamibi (MIBI) scintigraphy are commonly used imaging modalities in the era of minimally invasive parathyroidectomy (MIP) for primary hyperparathyroidism (pHPT). However, their relative importance and actual contribution to MIP have not been prospectively assessed. A total of 100 consecutive pHPT patients planning for MIP were recruited. Both USG and MIBI findings were correlated with intraoperative findings and postoperative outcome. Clinicopathologic factors were examined for potential association with a correct localizing result. Thirty men and 70 women (age range 13 to 93 years [median 55.5]) were included in the study. The final pathology included 98 patients with solitary adenoma and 2 patients with multiglandular disease. The sensitivities, accuracies, and positive predicted values for USG and MIBI alone were 57% vs 89%, 56% vs 85%, and 97% vs 94%, respectively. Correctly localized adenomas were significantly heavier than incorrectly localized ones. MIBI is preferred over USG in pHPT patients planning for MIP. Weight of adenoma appeared to be the only clinicopathologic factor determining localization accuracy.

  6. Experimental study of radiopharmaceuticals based on technetium-99m labeled derivative of glucose for tumor diagnosis

    NASA Astrophysics Data System (ADS)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Bragina, O.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.; Dergilev, A.

    2016-06-01

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 minutes at room temperature. After centrifugation of the vials with cells, the supernatant was removed. Radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B 1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 minutes. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D- glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3±0.15MBq and 1.07±0.6MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio- D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

  7. Study of potential utility of new radiopharmaceuticals based on technetium-99m labeled derivative of glucose

    NASA Astrophysics Data System (ADS)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Larionova, L.; Skuridin, V.

    2016-08-01

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with 99mTc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of 99mTc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with 99mTc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normal and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of 99mTc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with 99mTc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of 99mTc-1-thio-D-glucose at the tumor site. The accumulation of 99mTc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that 99mTc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of 99mTc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.

  8. /sup 99m/Tc-IDA imaging in the differential diagnosis of acute cholecystitis and acute pancreatitis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fonseca, C.; Greenberg, D.; Rosenthall, L.

    1979-02-01

    Technetium-/sup 99m/-labelled dimethly-acetanilide-iminodiacetic acid (/sup 99m/Tc-IDA) hepato-biliary imaging was evaluated for its efficacy in distinguishing acute cholecystitis from acute pancreatitis. In a retrospective review, gallbladders were demonstrated by /sup 99m/Tc-IDA in 13 of 15 patients (87%) with acute pancreatitis. This is significantly higher than reports on the frequency of gallbladder filling with oral and intravenous cholangiography in the presence of acute cholecystitis.

  9. Technetium 99m pertechnetate scans in congenital hypothyroidism

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bauman, R.A.; Bode, H.H.; Hayek, A.

    1976-08-01

    Goiters are rarely palpable in infants with congenital hypothyroidism except in the case of maternal ingestion of iodide. The presence or absence of glandular tissue is, however, important for genetic and prognostic counseling and for acceleration of diagnosis in other affected siblings. The detection of thyroid tissue by /sup 99m/Tc pertechnetate scans in a significant number of our patients heretofore considered athyreotic establishes that physical findings and traditional laboratory data are not adequate to determine whether or not thyroid tissue is present.

  10. THE RESULTS OF PARATHYROID HORMONE ASSAY IN PARATHYROID ASPIRATES IN PRE-OPERATIVE LOCALIZATION OF PARATHYROID ADENOMAS FOR FOCUSED PARATHYROIDECTOMY IN PATIENTS WITH NEGATIVE OR SUSPICIOUS TECHNETIUM-99M-SESTAMIBI SCANS.

    PubMed

    Ozderya, Aysenur; Temizkan, Sule; Cetin, Kenan; Ozugur, Sule; Gul, Aylin Ege; Aydin, Kadriye

    2017-09-01

    This study aimed to evaluate the results of parathyroid hormone (PTH) assay in parathyroid aspirates to determine uniglandular disease by an endocrinologist-performed ultrasound (US) in patients with discordant or negative technetium-sestamibi scans and to evaluate whether this procedure increases the number of focused parathyroidectomies (FPs). We analyzed the data of 65 patients who underwent an endocrinologist-performed US-guided parathyroid fine-needle aspiration (FNA) with PTH wash-out, retrospectively. The results of PTH wash-out procedure and the reports of parathyroid surgery and pathology were reviewed. Of 65 patients, 54 had positive PTH wash-out results. The median serum PTH level of patients with positive and negative PTH wash-out results was 143 (25 and 75% interquartile range [IQR], 114 to 197) versus 154 (IQR, 115 to 255) pg/mL (P = .45), and the median PTH in FNA was 3,533 (IQR, 1,481 to 3,534) versus 6.0 (IQR, 1 to 6) pg/mL (P<.001), respectively. Forty-five patients underwent surgery. Of the operated patients, 42 had positive PTH wash-out results and had successful FP. Four patients with redo surgery had positive PTH wash-out results and were successfully re-operated with FP. Of 11 patients with negative PTH wash-out results, 3 had bilateral neck exploration (BNE) surgery and 2 patients were successfully operated, while surgery was unsuccessful in 1 patient, despite BNE. Our study results suggest that endocrinologist-performed US and parathyroid FNA with PTH wash-out increases the number and success of FPs. In particular, patients with redo surgery may benefit from this procedure. 4D-CT = four-dimensional computed tomography BNE = bilateral neck exploration FNA = fine-needle aspiration FNAB = fine-needle aspiration biopsy FP = focused parathyroidectomy IQR = 25 and 75% inter-quartile range PHPT = primary hyperparathyroidism PPV = positive predictive value PTH = parathyroid hormone 99m Tc = technetium US = ultrasound.

  11. Study of potential utility of new radiopharmaceuticals based on technetium-99m labeled derivative of glucose

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zeltchan, R., E-mail: r.zelchan@yandex.ru; Medvedeva, A.; Sinilkin, I.

    Purpose: to study the potential utility of 1-thio-D-glucose labeled with {sup 99m}Tc for cancer imaging in laboratory animals. Materials and method: the study was carried out in cell cultures of normal CHO (Chinese hamster ovary cells CHO) and malignant tissues MCF-7 (human breast adenocarcinoma MCF-7). To evaluate the uptake of {sup 99m}Tc-1-thio-D-glucose in normal and tumor tissue cells, 25 MBq of 1-thio-D-glucose labeled with {sup 99m}Tc was added to the vials with 3 million cells and incubated for 30 min at room temperature. After centrifugation of the vials with cells, the supernatant was removed. The radioactivity in vials with normalmore » and tumor cells was then measured. In addition, the study included 40 mice of C57B1/6j lines with tumor lesion of the right femur. For neoplastic lesions, Lewis lung carcinoma model was used. Following anesthesia, mice were injected intravenously with 25 MBq of {sup 99m}Tc-1-thio-D-glucose. Planar scintigraphy was performed 15 minutes later in a matrix of 512x512 pixels for 5 min. Results: when measuring the radioactivity of normal and malignant cells after incubation with {sup 99m}Tc-1-thio-D-glucose, it was found that the radioactivity of malignant cells was higher than that of normal cells. The mean values of radioactivity levels in normal and malignant cells were 0.3 ± 0.15 MBq and 1.07 ± 0.6 MBq, respectively. All examined animals had increased accumulation of {sup 99m}Tc-1-thio-D-glucose at the tumor site. The accumulation of {sup 99m}Tc-1-thio-D-glucose in the tumor was on average twice as high as compared to the symmetric region. Conclusion: The present study demonstrated that {sup 99m}Tc-1-thio-D-glucose is a prospective radiopharmaceutical for cancer visualization. In addition, high accumulation of {sup 99m}Tc-1-thio-D-glucose in the culture of cancer cells and in tumor tissue of animals demonstrates tumor tropism of the radiopharmaceutical.« less

  12. Imaging of glutathione localization in brain with technetium-99M meso-hexamethyl propyleneamine oxime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, T.; Toyama, H.; Oda, K.

    1995-05-01

    Previous studies have shown decreasing [Tc-99m] meso-HM-PAO uptake in accordance with glutathione (GSH) content in diethyl, maleate (DEM) treated mice brain. In order to elucidate the retention mechanism of [Tc-99m] HM-PAO in brain and to visualize the regional localization of GSH in the brain with [Tc-99m] meso-HM-PAO, the relationship between the tissue GSH content and uptake of [Tc-99m] meso-HM-PAO was studied in rats and rabbits. Increasing pre-load of DEM (550 mg/kg body weight), an agent to reduce GSH content by glutathione transferase, led to a decrease in GSH (control 1.972{plus_minus}0.017 vs DEM 1.138{plus_minus}0.106 mM) and uptake of [Tc-99m] meso-HM-PAO tomore » half of the control in the rat brain (control 0.281{plus_minus}0.024 vs DEM 0.153 {plus_minus} 0.009 % dose/g). On the other hand, the DEM did not decrease GSH or the uptake of [Tc-99m] meso-HM-PAO in the rabbit brain, in which glutathione transferase activity is very low. These results were also demonstrated by images with pin-hole collimated gamma camera. The uptake of [Tc-99m] meso showed variations in the regional distribution, but the d,l-isomer was uniform. [Tc-99m] meso-HM-PAO uptake was well correlated with GSH content in mice brain regions (r=0.800, p<0.02), whereas [Tc-99m]d,l-HM-PAO was not (r=0.017, p>0.5). Both [Tc-99m] mesa HM-PAO uptake and GSH content were especially high at cerebellum (Uptake: 2.598{plus_minus}0.256 % dose/g. GSH: 2.372{plus_minus}0.107 mM) as compared to other areas (Uptake;cerebral cortex 1.797{plus_minus}0.100 brain stem 1.607 {plus_minus}0.112 % dose/g. GSH: cerebral cortex 1.635{plus_minus}0.142 brain stem 1.478{plus_minus}0.141 mM).« less

  13. Structural characterization of a bridged 99Tc-Sn-dimethylglyoxime complex: implications for the chemistry of 99mTc-radiopharmaceuticals prepared by the Sn (II) reduction of pertechnetate.

    PubMed Central

    Deutsch, E; Elder, R C; Lange, B A; Vaal, M J; Lay, D G

    1976-01-01

    Reduction of pertechnetate by tin(II) in the presence of dimethylglyoxime is shown, by single crystal x-ray analysis, to yield a technetium-tin-dimethylglyoxime complex in which tin and technetium are intimately connected by a triple bridging arrangement. One bridge consists of a single oxygen atom and it is hypothesized that this bridge arises from the inner sphere reduction of technetium by tin(II), the electrons being transferred through a technetium "yl" oxygen which eventually becomes the bridging atom. Two additional bridges arise from two dimethylglyoxime ligands that function as bidentate nitrogen donors towards Tc and monodentate oxygen donors towards Sn. The tin atom can thus be viewed as providing a three-pronged "cap" on one end of the Tc-dimethylglyoxime complex. The additional coordination sites around Tc are occupied by the two nitrogens of a third dimethylglyoxime ligand, making the Tc seven-coordinate. The additional coordination sites around Sn are occupied by three chloride anions, giving the Sn a fac octahedral coordination environment. From indirect evidence the oxidation states of tin and technetium are tentatively assigned to be IV and V, respectively. Since most 99mTc-radiopharmaceuticals are synthesized by the tin(II) reduction of pertechnetate, it is likely that the Sn-O-Tc linkage described in this work is an important feature of the chemistry of these species. This linkage also provides a ready rationale for the close association of tin and technetium observed in many 99mTc-radiopharmaceuticals. PMID:1069984

  14. In vitro and in vivo comparison of binding of 99m-Tc-labeled anti-CEA MAb F33-104 with 99m-Tc-labeled anti-CEA MAb BW431/26.

    PubMed

    Watanabe, N; Oriuchi, N; Sugiyama, S; Kuroki, M; Matsuoka, Y; Tanada, S; Murata, H; Inoue, T; Sasaki, Y

    1999-01-01

    The purpose of this study was to assess the potential for radio-immunodetection (RAID) of murine anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb) F33-104 labeled with technetium-99m (99m-Tc) by a reduction-mediated labeling method. The binding capacity of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA by means of in vitro procedures such as immunoradiometric assay and cell binding assay and the biodistribution of 99m-Tc-labeled anti-CEA MAb F33-104 in normal nude mice and nude mice bearing human colon adenocarcinoma LS180 tumor were investigated and compared with 99m-Tc-labeled anti-CEA MAb BW431/26. The in vitro binding rate of 99m-Tc-labeled anti-CEA MAb F33-104 with CEA in solution and attached to the cell membrane was significantly higher than 99m-Tc-labeled anti-CEA MAb BW431/261 (31.4 +/- 0.95% vs. 11.9 +/- 0.55% at 100 ng/mL of soluble CEA, 83.5 +/- 2.84% vs. 54.0 +/- 2.54% at 10(7) of LS 180 cells). In vivo, accumulation of 99m-Tc-labeled anti-CEA MAb F33-104 was higher at 18 h postinjection than 99m-Tc-labeled anti-CEA MAb BW431/26 (20.1 +/- 3.50% ID/g vs. 14.4 +/- 3.30% ID/g). 99m-Tc-activity in the kidneys of nude mice bearing tumor was higher at 18 h postinjection than at 3 h (12.8 +/- 2.10% ID/g vs. 8.01 +/- 2.40% ID/g of 99m-Tc-labeled anti-CEA MAb F33-104, 10.7 +/- 1.70% ID/g vs. 8.10 +/- 1.75% ID/g of 99m-Tc-labeled anti-CEA MAb BW431/26). 99m-Tc-labeled anti-CEA MAb F33-104 is a potential novel agent for RAID of recurrent colorectal cancer.

  15. Sentinel lymph node mapping in melanoma with technetium-99m dextran.

    PubMed

    Neubauer, S; Mena, I; Iglesis, R; Schwartz, R; Acevedo, J C; Leon, A; Gomez, L

    2001-06-01

    The aim of this work is to evaluate the capability of Tc99m B Dextran as a lymphoscintigraphic agent in the detection of the sentinel node in skin lesions. Forty-one patients with melanomas (39) and Merkel cell tumors (2) had perilesional intradermal injection of Tc99m-Dextran 2 hours before surgery. Serial gamma camera images and a handheld gamma probe were used to direct sentinel node biopsy. In 39/41 patients, lymph channels and 52 sentinel nodes (one to three sentinel nodes/patient) could be visualized. In one patient, with a dorsal melanoma, no lymph channels or lymph nodes could be demonstrated on the images and only minimal radioactivity was found in the regional nodes with the probe. Another patient with a facial lesion failed to demonstrate lymph channels or nodes. No adverse reactions were observed. Tc99m-Dextran provided good definition of lymph channels and sentinel node localization, without the risks related to the use of potentially hazardous labeled materials of biological origin.

  16. Comparison of 99mTc-UBI 29-41, 99mTc-Ciprofloxacin, 99mTc-Ciprofloxacin dithiocarbamate and 111In-biotin for targeting experimental Staphylococcus aureus and Escherichia coli foreign-body infections: an ex-vivo study.

    PubMed

    Auletta, Sveva; Baldoni, Daniela; Varani, Michela; Galli, Filippo; Hajar, Iman A; Duatti, Adriano; Ferro-Flores, Guillermina; Trampuz, Andrej; Signore, Alberto

    2017-08-28

    Diagnosis of implant-associated infection is challenging. Several radiopharmaceuticals have been described but direct comparisons are limited. Here we compared in vitro and in an animal model 99mTc-UBI, 99mTc-Ciprofloxacin, 99mTcN-CiproCS2 and 111In-DTPA-biotin for targeting E. coli (ATCC 25922) and S. aureus (ATCC 43335). Stability controls were performed with the labelled radiopharmaceuticals during 6 h in saline and serum. The in vitro binding to viable or killed bacteria was evaluated at 37 °C and 4 °C. For in vivo studies, Teflon cages were subcutaneously implanted in mice, followed by percutaneous infection. Biodistribution of i.v. injected radiolabelled radiopharmaceuticals were evaluated during 24 h in cages and dissected tissues. Labelling efficiency of all radiopharmaceuticals ranged between 94% and 98%, with high stability both in saline and in human serum. In vitro binding assays displayed a rapid but poor bacterial binding for all tested agents. Similar binding kinetic occurred also with heat-killed and ethanol-killed bacteria. In the tissue cage model, infection was detected at different time points: 99mTc-UBI and 99mTcN-CiproCS2 showed higher infected cage/sterile cage ratio at 24 h for both E. coli and S. aureus; 99mTc-Ciprofloxacin at 24 h for both E. coli and at 4 h for S. aureus; 111In-DTPA-biotin accumulates faster in both E. coli and S. aureus infected cages. 99mTc-UBI, 99mTcN-CiproCS2 showed poor in vitro binding but good in vivo binding to E. coli only. 111In-DTPA-biotin showed poor in vitro binding but good in vivo binding to S. aureus and poor to E. coli. 99mTc-Ciprofloxacin showed poor in vitro binding but good in vivo binding to all tested bacteria. The mechanism of accumulation in infected sites remains to be elucidated.

  17. Preparation of Tc-99m-macroaggregated albumin from recombinant human albumin for lung perfusion imaging.

    PubMed

    Hunt, A P; Frier, M; Johnson, R A; Berezenko, S; Perkins, A C

    2006-01-01

    Human serum albumin (HSA) extracted from pooled blood taken from human donors is used in the production of (99m)Tc-labelled macroaggregated albumin (MAA) for lung perfusion imaging. However, concerns for the safety of blood-derived products due to potential contamination by infective agents (e.g. new variant CJD), make alternative production methods necessary. Recombinant DNA technology is a promising method of albumin production avoiding problems associated with human-derived HSA. This paper presents results comparing MAA prepared from recombinant human albumin (rHA, Recombumin) (rMAA) with in-house produced HSA MAA (hMAA) and commercially available MAA (cMAA). (99m)Tc-MAA was prepared using previously published production methods by heating a mixture of albumin and stannous chloride in acetate buffer (pH 5.4) at 70 degrees C for 20 min. Parameters investigated include aggregate size, radiolabelling efficiency, radiochemical and aggregate stability at 4 degrees C and in vitro (in whole human blood) at 37 degrees C and biodistribution studies. Results showed that rMAA could be produced with similar morphology, labelling efficiency and stability to hMAA and cMAA. Our findings confirm that rHA shows significant potential as a direct replacement for HSA in commercially available MAA.

  18. Myocardial uptake and kinetic properties of technetium-99m-Q3 in dogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gerson, M.C.; Millard, R.W.; McGoron, A.J.

    1994-10-01

    We postulated that {sup 99m}Tc-Q3, a cationic imaging agent, produces myocardial activity related to myocardial blood flow during myocardial ischemia and pharmacologic coronary artery vasodilation, and shows little or no myocardial redistribution over 4 hr after intravenous injection. In six Group 1 dogs, the chest was opened, the left circumflex coronary artery was acutely ligated, and dipyridamole (0.32, 0.56 or 0.84 mg/kg) was infused into the right atrium, followed by 10 mCi of {sup 99m}Tc-Q3. Myocardial blood flow was measured by radiolabeled microspheres. The animals were euthanized and 357 myocardial samples were assayed in a well counter for {sup 99m}Tcmore » activity. One week later, radiolabeled microsphere activity was counted and myocardial blood flow calculated. In nine Group 2 dogs, a variable occluder was placed around the left circumflex coronary artery and an ischemic level of circumflex blood flow was maintained constant over 4 hr as measured by an ultrasonic flow meter. Dipyridamole (0.56 mg/kg) was then infused into the right atrium followed by 10mCi of {sup 99m}Tc-Q3. Gamma camera images were acquired at 5, 15, 30, 60, 120 and 240 min following k{sup 99m}Tc-Q3 injection. Microsphere blood flow and endocardial biopsies (n - 6 dogs) were performed at 30, 60, 120 and 240 min following {sup 99m}TcQ3 injection. 31 refs., 9 figs., 1 tab.« less

  19. Two peptide receptor ligands (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide and (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin for scintigraphy of medullary thyroid carcinoma.

    PubMed

    Kosowicz, Jerzy; Mikołajczak, Renata; Czepczyński, Rafał; Ziemnicka, Katarzyna; Gryczyńska, Maria; Sowiński, Jerzy

    2007-10-01

    Somatostatin and gastrin receptors are overexpressed in medullary thyroid carcinoma (MTC) cells; hence, both of them are potential targets for peptide receptor scintigraphy and radiotherapy. Therefore, the aim of our study was to assess the clinical value of two technetium-99m-labeled peptides, a new gastrin analog, the EDDA/HYNIC-(D)Glu-octagastrin and a somatostatin analog, EDDA/HYNIC-Tyr(3)-octreotide (EDDA/HYNIC-TOC) for scintigraphy in patients with MTC to detect recurrences and metastases and select patients for peptide receptor radiotherapy. Thirty (30) patients, 20 females and 10 males, 22-83 years of age (mean, 52.7) with the diagnosis of MTC in different stages of the disease (preoperative, postsurgery, remission, recurrence, or metastatic disease) were included in this study. Before surgery, in all patients serum calcitonin concentrations were elevated. The diagnosis of MTC was confirmed in all cases by histopathology of the removed tumor and immunohistochemical staining giving positive reactions for calcitonin and chromogranin A. Imaging studies using (99m)Tc-EDDA/HYNIC-TOC and a new minigastrin analog, (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin, were performed in each patient and the results compared with each other and with other imaging methods. Scans of the whole body, head, neck, and chest were performed 2 and 4 hours after injections of the tracer, 500-600 MBq in each case, using a double-head Varicam (Elscint, Israel) gamma camera. (99m)Tc-EDDA/HYNIC-TOC detected somatostatin receptor-positive lesions in 20 patients with MTC, whereas (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin displayed gastrin receptors in 11 patients. In 9 cases, the scans were positive in both methods, although in 2 cases different pathologic foci were visualized. In 12 cases, only (99m)Tc-EDDA/HYNIC-TOC scintigraphy was positive, whereas in 3 other cases only (99m)Tc-EDDA/HYNIC-(D)Glu-octagastrin revealed pathologic lesions. Scintigraphy using (99m)Tc-HYNIC-TOC permits the visualization

  20. 99mTc-N4-[Tyr3]Octreotate Versus 99mTc-EDDA/HYNIC-[Tyr3]Octreotide: an intrapatient comparison of two novel Technetium-99m labeled tracers for somatostatin receptor scintigraphy.

    PubMed

    Gabriel, Michael; Decristoforo, Clemens; Maina, Theodosia; Nock, Berthold; vonGuggenberg, Elisabeth; Cordopatis, Paul; Moncayo, Roy

    2004-02-01

    Tetraamine-[Tyr3]octreotate (Demotate) is a somatostatin (SST) analogue that can be easily labeled with 99mTc at high specific activities and showed promising preclinical properties for SST receptor scintigraphy. This study reports on the first intra-patient comparison of 99mTc-Demotate and another 99mTc-labeled SST analogue, 99mTc-EDDA/HYNIC-TOC (HYNIC-TOC). Five patients with carcinoid tumors (n = 2) and endocrine pancreatic tumors (n = 3) were investigated with both radiopharmaceuticals. 99mTc-Demotate rapidly visualized somatostatin receptor positive tumors as early as 15 minutes post-injection (p.i.) with maximum tumor uptake and tumor/organ ratios already 1 hour p.i. Organs of predominant physiological uptake were the spleen and the kidneys with no intestinal excretion detectable up to 24 hours. 99mTc-Demotate exhibited faster pharmacokinetic properties compared to HYNIC-TOC. Tumor/organ ratios at equivalent time points were higher or comparable for 99mTc-Demotate in three patients with a matching scan result. Equivocal findings were observed in two patients, i.e. comparable uptake behavior in larger lesions with differences in smaller ones. 99mTc-Demotate is a promising agent for somatostatin receptor scintigraphy providing images of excellent quality as early as 1 hour after injection.

  1. The study of interaction of modified fatty acid with {sup 99m}Tc in alcoholic media

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Skuridin, V. S.; Stasyuk, E. S.; Varlamova, N. V.

    2016-08-02

    The paper presents the results of laboratory research aimed at the development of methods of synthesis of new radiodiagnostic agents based on modified fatty acid labelled with technetium-99m intended for scintigraphic evaluation of myocardial metabolism. In particular, the interaction of substance with {sup 99m}Tc in alcoholic media and the use of ethanol as solvent in the synthesis of the radiopharmaceutical were studied.

  2. Comparison of early myocardial technetium-99m pyrophosphate uptake to early peaking of creatine kinase and creatine kinase-MB as indicators of early reperfusion in acute myocardial infarction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kondo, M.; Yuzuki, Y.; Arai, H.

    1987-10-01

    The value of technetium-99m pyrophosphate (Tc-99m-PYP) scintigraphy as an indicator of reperfusion 2.8 to 8 hours after the onset of symptoms of acute myocardial infarction was compared with the value of early peak creatine kinase (CK) and CK-MB release within 16 hours after the onset of symptoms. In 29 patients who received thrombolytic therapy, recanalization was seen (group 1) and in 7 it was not (group 2). In 23 patients (79%) in group 1 scintigraphic findings were positive and in all 7 in group 2 they were negative. In 15 patients (52%) in group 1 and 1 patient (14%) inmore » group 2, CK reached its peak level within 16 hours. In 20 patients (69%) in group 1 and 3 (43%) in group 2 the CK-MB level reached a peak within 16 hours. The sensitivity, specificity and predictive accuracy of positive results of early Tc-99m-PYP scintigraphy in predicting the reperfusion were 79%, 100% and 83%. These values are significantly higher than or similar to those of early peaking of CK and CK-MB release. In contrast to measurements of enzyme release, reperfusion data for Tc-99m-PYP scintigraphy are available immediately after thrombolytic therapy. Therefore, early Tc-99m-PYP scintigraphy (3 to 8 hours after onset of symptoms) is valuable as a noninvasive technique for early diagnosis of reperfusion.« less

  3. 99mTc: Labeling Chemistry and Labeled Compounds

    NASA Astrophysics Data System (ADS)

    Alberto, R.; Abram, U.

    This chapter reviews the radiopharmaceutical chemistry of technetium related to the synthesis of perfusion agents and to the labeling of receptor-binding biomolecules. To understand the limitations of technetium chemistry imposed by future application of the complexes in nuclear medicine, an introductory section analyzes the compulsory requirements to be considered when facing the incentive of introducing a novel radiopharmaceutical into the market. Requirements from chemistry, routine application, and market are discussed. In a subsequent section, commercially available 99mTc-based radiopharmaceuticals are treated. It covers the complexes in use for imaging the most important target organs such as heart, brain, or kidney. The commercially available radiopharmaceuticals fulfill the requirements outlined earlier and are discussed with this background. In a following section, the properties and perspectives of the different generations of radiopharmaceuticals are described in a general way, covering characteristics for perfusion agents and for receptor-specific molecules. Technetium chemistry for the synthesis of perfusion agents and the different labeling approaches for target-specific biomolecules are summarized. The review comprises a general introduction to the common approaches currently in use, employing the N x S4-x , [3+1] and 2-hydrazino-nicotinicacid (HYNIC) method as well as more recent strategies such as the carbonyl and the TcN approach. Direct labeling without the need of a bifunctional chelator is briefly reviewed as well. More particularly, recent developments in the labeling of concrete targeting molecules, the second generation of radiopharmaceuticals, is then discussed and prominent examples with antibodies/peptides, neuroreceptor targeting small molecules, myocardial imaging agents, vitamins, thymidine, and complexes relevant to multidrug resistance are given. In addition, a new approach toward peptide drug development is described. The section

  4. The Evaluation of Novel Tin Materials for the Removal of Technetium from Groundwater

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parker, Kent E.; Wellman, Dawn M.

    2017-06-30

    Technetium-99 ( 99Tc) is present at several U.S. Department of Energy (DOE) facilities, including the Hanford, Oak Ridge, Paducah, Portsmouth, and Savannah River sites. Due to its mobility, persistence, and toxicity in the environment, developing means to immobilize and/or remove technetium from the environment is currently a top priority for DOE. However, there are currently very few approaches that effectively manage the risks of technetium to human health and the environment. The objective of this study is to evaluate novel synthetic materials that could enable direct removal of technetium from groundwater. The following report •assesses the viability of existing methodologiesmore » for synthesis of tin (II) apatite for in situ formation and remediation of 99Tc within the subsurface environment •discusses the development of alternative methodologies for production of tin (II) apatite •evaluates nanoporous tin phosphate materials for removal of technetium from groundwater.« less

  5. Synthesis, Characterization and Biological Studies of 99mTc and 188Re Peptides

    NASA Astrophysics Data System (ADS)

    Sanders, Vanessa

    Radiopharmaceuticals are very powerful diagnostic tools for evaluation of a host of medical conditions. These drugs are labeled with radioactive isotopes, which are utilized to create pictures of areas of interest through absorption of the drug. They are currently in high demand due to their ability to image areas that traditional imaging devices cannot. The radioisotope 99mTc, with a half-life of 6.01 hours and a 140 keV gamma emission, is central to many radiopharmaceutical compounds. This isotope is easily obtained from a 99Mo-99mTc generator, through beta decay and column chromatography separations. Very little technetium, less than 6 ng, is needed to label the pharmaceuticals for use in-vivo. Another radioisotope 188Re is also important due to its ability to be used for therapy while being tracked throughout the body. Radiotherapy gives radiopharmaceuticals a huge advantage by their ability to destroy rapidly growing cells. One of the main reasons there is interest in rhenium pharmaceuticals is the chemical similarity between it and technetium. The 188Re isotope also has a considerably short half-life of approximately 17 hours and has emission energy of 155 keV. The 188Re isotope is separated from 188W-188Re generator, analogously to the 99Mo-99mTc generator. The ligand used in this work is a pentapepetide macrocyclic ligand. This ligand, KYCAR (lysyl-tyrosyl-cystyl-alanyl-arginine), has been designed as a potential chelating ligand for imaging and therapeutic in vivo agents. Ligands are chosen based on their in-situ biological behavior, and are used in the complexation with technetium and rhenium. Understanding and exploiting technetium and rhenium chemistry can provide insight into the reaction mechanisms and coordination chemistry of these compounds. The exploration of various oxidation states as a function of the ligands used and the reaction conditions can help develop novel radiopharmaceuticals. The investigations of the manipulation of oxidation states

  6. Bone scanning in lymphoma. [/sup 99m/Tc tracer technique

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schechter, J.P.; Jones, S.E.; Woolfenden, J.M.

    1976-09-01

    The results of bone scanning with the newer technetium-99m complexes were correlated with clinical, laboratory, and radiographic findings in 26 patients with malignant lymphoma (10 with Hodgkin's disease and 16 with non-Hodgkin's lymphomas). Abnormalities on bone scan compatible with lymphomatous involvement of the skeleton appeared to occur more commonly in patients with diffuse lymphomas than in patients with nodular lymphomas and were generally observed in the setting of advanced disease (15 of 23 patients). Twenty-seven (73 percent) of the 37 scans obtained were abnormal. Although abnormal scans were observed with the greatest frequency in patients with bone pain (11 ofmore » 11), bone marrow involvement (11 of 12), abnormal skeletal radiographs (11 of 11), and elevated serum alkaline phosphatase levels (5 of 6), bone scanning also detected lymphomatous involvement in patients free of pain or with normal laboratory tests. Moreover, conventional radiography was entirely normal in six (35 percent) of 17 patients with abnormal scans and revealed only nonspecific osteopenia in another two patients (12 percent). Serial bone scans in nine patients reflected their response to chemotherapy. Of the 37 scans, only one was judged falsely positive and one falsely negative. Bone scanning with /sup 99m/Tc complexes is a safe, simple, and sensitive screening procedure for detecting both extensive and focal lymphomatous involvement of the skeletal system and is a useful means of following such involvement in response to treatment.« less

  7. Magnetic core mesoporous silica nanoparticles doped with dacarbazine and labelled with 99mTc for early and differential detection of metastatic melanoma by single photon emission computed tomography.

    PubMed

    Portilho, Filipe Leal; Helal-Neto, Edward; Cabezas, Santiago Sánchez; Pinto, Suyene Rocha; Dos Santos, Sofia Nascimento; Pozzo, Lorena; Sancenón, Félix; Martínez-Máñez, Ramón; Santos-Oliveira, Ralph

    2018-02-27

    Cancer is responsible for more than 12% of all causes of death in the world, with an annual death rate of more than 7 million people. In this scenario melanoma is one of the most aggressive ones with serious limitation in early detection and therapy. In this direction we developed, characterized and tested in vivo a new drug delivery system based on magnetic core-mesoporous silica nanoparticle that has been doped with dacarbazine and labelled with technetium 99 m to be used as nano-imaging agent (nanoradiopharmaceutical) for early and differential diagnosis and melanoma by single photon emission computed tomography. The results demonstrated the ability of the magnetic core-mesoporous silica to be efficiently (>98%) doped with dacarbazine and also efficiently labelled with 99mTc (technetium 99 m) (>99%). The in vivo test, using inducted mice with melanoma, demonstrated the EPR effect of the magnetic core-mesoporous silica nanoparticles doped with dacarbazine and labelled with technetium 99 metastable when injected intratumorally and the possibility to be used as systemic injection too. In both cases, magnetic core-mesoporous silica nanoparticles doped with dacarbazine and labelled with technetium 99 metastable showed to be a reliable and efficient nano-imaging agent for melanoma.

  8. Mammary lymphoscintigraphy with various radiopharmaceuticals in breast cancer.

    PubMed

    Imoto, S; Murakami, K; Ikeda, H; Fukukita, H; Moriyama, N

    1999-10-01

    Sentinel node biopsy (SNB) in breast cancer is a promising surgical technique that avoids unnecessary axillary lymph node dissection. To optimize lymphatic mapping with radiopharmaceuticals, mammary lymphoscintigraphy with 30-50 MBq of technetium-99m-diethylenetriamine pentaacetic acid human serum albumin (99mTc-HSAD), technetium-99m-human serum albumin (99mTc-HSA), or technetium-99m-tin colloid (99mTc-TC) were investigated in 69 cases of primary breast cancer. Dynamic early images were obtained during the first 30 or 40 minutes, and static delayed images were obtained 6 hours after tracer injection. Hot spots as sentinel lymph nodes (SLNs) appeared in 51 of 69 cases (74%): in early images in 27 cases and in delayed images in 24 cases. SLNs were visualized more frequently in 23 of the 26 cases (88%) treated with 99mTc-HSAD and in 21 of the 24 cases (88%) treated with 99mTc-HSA than in only 7 of the 19 cases (37%) treated with 99mTc-TC. In 26 of the 51 cases, SLNs were identified as faint spots in delayed images. There was a significant difference in the first appearance of SLNs on the lymphoscintiscan between 43 cases of dense breast parenchyma and 26 cases of fatty breast parenchyma. These results suggest that 99mTc-HSAD or 99mTc-HSA is acceptable for lymphatic mapping, but in cases which have faint spots in delayed images or fatty breast parenchyma, gamma probe-guided SNB may result in failure or misleading false-negative SLNs.

  9. Radiolabeled, nonspecific, polyclonal human immunoglobulin in the detection of focal inflammation by scintigraphy: Comparison with gallium-67 citrate and technetium-99m-labeled albumin

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rubin, R.H.; Fischman, A.J.; Needleman, M.

    1989-03-01

    The accumulation of nonspecific polyclonal human immunoglobulin (IgG) radiolabeled with /sup 125/I or /sup 111/In was compared to that of (/sup 67/Ga)citrate and (/sup 99m/Tc)albumin in rats with deep thigh inflammation due to Escherichia coli infection. Serial scintigrams were acquired at 1, 3, 24, and in some cases, 48 hr after injection. As early as 3 hr postinjection, (/sup 111/In)IgG showed greater accumulation at the lesion than (/sup 99m/Tc)HSA (p less than 0.01). Both (/sup 125/I)IgG and (/sup 111/In)IgG showed greater accumulation than (/sup 67/Ga)citrate (p less than 0.01). At 24 hr, IgG image definition increased, while HSA image definitionmore » decreased, and the intensity of accumulation of both IgG preparations was greater than that of (/sup 67/Ga)citrate or (/sup 99m/Tc)HSA (p less than 0.01). At all imaging times, (/sup 67/Ga)citrate accumulation was surprisingly low. In inflammation produced by Pseudomonas aeruginosa, Staphylococcus aureus, Klebsiella pneumoniae, Candida albicans, or turpentine, (/sup 111/In)IgG accumulation was similar to the results obtained with Escherichia coli. These studies suggest that focal sites of inflammation can be detected with radiolabeled nonspecific human polyclonal IgG.« less

  10. Radiolabeling of VEGF165 with 99mTc to evaluate VEGFR expression in tumor angiogenesis.

    PubMed

    Galli, Filippo; Artico, Marco; Taurone, Samanta; Manni, Isabella; Bianchi, Enrica; Piaggio, Giulia; Weintraub, Bruce D; Szkudlinski, Mariusz W; Agostinelli, Enzo; Dierckx, Rudi A J O; Signore, Alberto

    2017-06-01

    Angiogenesis is the main process responsible for tumor growth and metastatization. The principal effector of such mechanism is the vascular endothelial growth factor (VEGF) secreted by cancer cells and other components of tumor microenvironment. Radiolabeled VEGF analogues may provide a useful tool to noninvasively image tumor lesions and evaluate the efficacy of anti-angiogenic drugs that block the VEGFR pathway. Aim of the present study was to radiolabel the human VEGF165 analogue with 99mTechnetium (99mTc) and to evaluate the expression of VEGFR in both cancer and endothelial cells in the tumor microenvironment. 99mTc-VEGF showed in vitro binding to HUVEC cells and in vivo to xenograft tumors in mice (ARO, K1 and HT29). By comparing in vivo data with immunohistochemical analysis of excised tumors we found an inverse correlation between 99mTc-VEGF165 uptake and VEGF histologically detected, but a positive correlation with VEGF receptor expression (VEGFR1). Results of our studies indicate that endogenous VEGF production by cancer cells and other cells of tumor microenvironment should be taken in consideration when performing scintigraphy with radiolabeled VEGF, because of possible false negative results due to saturation of VEGFRs.

  11. Solar neutrino production of technetium-97 and technetium-98.

    PubMed

    Cowan, G A; Haxton, W C

    1982-04-02

    It may be possible to determine the boron-8 solar neutrino flux, averaged over the past several million years, from the concentration of technetium-98 in molybdenite. The mass spectrometry of this system is greatly simplified by the absence of stable technetium isotopes, and the presence of the fission product technetium-99 provides a monitor of uiranium-induced backgrounds. This geochemical experiment could provide the first test of nonstandard solar models that suggest a relation between the chlorine-37 solar neutrino puzzle and the recent ice age.

  12. Development and study of 99mTc-1-Thio-D-glucose for visualization of malignant tumors

    NASA Astrophysics Data System (ADS)

    Zeltchan, R.; Medvedeva, A.; Sinilkin, I.; Bragina, O.; Chernov, V.; Stasyuk, E.; Rogov, A.; Il'ina, E.; Skuridin, V.

    2017-09-01

    The preclinical studies of 99mTc-1-Thio-D-glucose, a new tumor-seeking agent based on technetium-99m-labeled glucose derivative, were conducted, and the feasibility of using this radiopharmaceutical for tumor visualization was studied. The preclinical studies were carried out strictly in accordance with the local legislation and were regulated by the generally accepted research standards. 99mTc-1-Thio-D-glucose was found to have optimal pharmacokinetic and physico-chemical properties for diagnostic imaging and was proved to belong to the low-toxic substances. The potential utility of 99mTc-1-thio-D-glucose for tumor imaging was studied in vitro and in vivo models. The present study demonstrated that 99mTc-1-Thio-D-glucose is a prospective radiopharmaceutical for cancer visualization.

  13. Cortical perfusion response to an electrical stimulation of the auditory nerve in profoundly deaf patients: study with technetium-99m hexamethylpropylene amine oxime single photon emission tomography.

    PubMed

    Le Scao, Y; Robier, A; Baulieu, J L; Beutter, P; Pourcelot, L

    1992-01-01

    Brain activation procedures associated with single photon emission tomography (SPET) have recently been developed in healthy controls and diseased patients in order to help in their diagnosis and treatment. We investigated the effects of a promontory test (PT) on the cerebral distribution of technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) in 7 profoundly deaf patients, 6 PT+ and one PT-. The count variation in the temporal lobe was calculated on 6 coronal slices using the ratio (Rstimulation-Rdeprivation)/Rdeprivation where R = counts in the temporal lobe/whole-brain count. A count increase in the temporal lobe was observed in all patients and was higher in all patients with PT+ than in the patient with PT-. The problems of head positioning and resolution of the system were taken into account, and we considered that the maximal count increment was related to the auditory cortex response to the stimulus. Further clinical investigations with high-resolution systems have to be performed in order to validate this presurgery test in cochlear implant assessment.

  14. Biliary excretion of technetium-99m-sestamibi in wild-type dogs and in dogs with intrinsic (ABCB1-1Delta mutation) and extrinsic (ketoconazole treated) P-glycoprotein deficiency.

    PubMed

    Coelho, J C; Tucker, R; Mattoon, J; Roberts, G; Waiting, D K; Mealey, K L

    2009-10-01

    P-glycoprotein (P-gp), the product of ABCB1 gene, is thought to play a role in the biliary excretion of a variety of drugs, but specific studies in dogs have not been performed. Because a number of endogenous (ABCB1 polymorphisms) and exogenous (pharmacological P-gp inhibition) factors can interfere with normal P-gp function, a better understanding of P-gp's role in biliary drug excretion is crucial in preventing adverse drug reactions and drug-drug interactions in dogs. The objectives of this study were to compare biliary excretion of technetium-99m-sestamibi ((99m)Tc-MIBI), a radio-labelled P-gp substrate, in wild-type dogs (ABCB1 wild/wild), and dogs with intrinsic and extrinsic deficiencies in P-gp function. Dogs with intrinsic P-gp deficiency included ABCB1 mut/mut dogs, and dogs with presumed intermediate P-gp phenotype (ABCB1 mut/wild). Dogs with extrinsic P-gp deficiency were considered to be ABCB1 wild/wild dogs treated with the P-gp inhibitor ketoconazole (5 mg/kg PO q12h x 9 doses). Results from this study indicate that ABCB1 mut/mut dogs have significantly decreased biliary excretion of (99m)Tc-MIBI compared with ABCB1 wild/wild dogs. Treatment with ketoconazole significantly decreased biliary excretion of (99m)Tc-MIBI in ABCB1 wild/wild dogs. P-gp appears to play an important role in the biliary excretion of (99m)Tc-MIBI in dogs. It is likely that concurrent administration of a P-gp inhibitor such as ketoconazole will decrease P-gp-mediated biliary excretion of other substrate drugs as well.

  15. New method for the selective labeling of erythrocytes in whole blood with Tc-99m

    DOEpatents

    Srivastava, S.C.; Babich, J.W.; Straub, R.; Richards, P.

    1984-01-27

    Method and kit are described for the preparation of /sup 99m/Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available therein for the reduction of technetium.

  16. Evaluation of interobserver variability of parenchymal phase of Tc-99m mercaptoacetyltriglycine and Tc-99m dimercaptosuccinic acid renal scintigraphy

    PubMed Central

    Erdoğan, Zeynep; Abdülrezzak, Ümmühan; Silov, Güler; Özdal, Ayşegül; Turhal, Özgül

    2014-01-01

    Objective: The aim of this study was to investigate the variability in the interpretation of parenchymal abnormalities and to assess the differences in interpretation of routine renal scintigraphic findings on posterior view of technetium-99m dimercaptosuccinic acid (pvDMSA) scans and parenchymal phase of technetium-99m mercaptoacetyltriglycine (ppMAG3) scans by using standard criterions to make standardization and semiquantitative evaluation and to have more accurately correlation. Materials and Methods: Two experienced nuclear medicine physicians independently interpreted pvDMSA scans of 204 and ppMAG3 scans of 102 pediatric patients, retrospectively. Comparisons were made by visual inspection of pvDMSA scans, and ppMAG3 scans by using a grading system modified from Itoh et al. According to this, anatomical damage of the renal parenchyma was classified into six types: Grade 0-V. In the calculation of the agreement rates, Kendall correlation (tau-b) analysis was used. Results: According to our findings, excellent agreement was found for DMSA grade readings (DMSA-GR) (tau-b = 0.827) and good agreement for MAG3 grade readings (MAG3-GR) (tau-b = 0.790) between two observers. Most of clear parenchymal lesions detected on pvDMSA scans and ppMAG3 scans identified by observers equally. Studies with negative or minimal lesions reduced correlation degrees for both DMSA-GR and MAG3-GR. Conclusion: Our grading system can be used for standardization of the reports. We conclude that standardization of criteria and terminology in the interpretations may result in higher interobserver consistency, also improve low interobserver reproducibility and objectivity of renal scintigraphy reports. PMID:24761059

  17. Effect of Technetium-99 sources on its retention in low activity waste glass

    NASA Astrophysics Data System (ADS)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong; Wang, Guohui; Schweiger, Michael J.; Soderquist, Chuck Z.; Lukens, Wayne; Kruger, Albert A.

    2018-05-01

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO2•2H2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.

  18. Detection of urinary extravasation by delayed technetium-99m DTPA renal imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taki, J.; Tonami, N.; Aburano, T.

    Delayed imaging with Tc-99m DTPA renal scintigraphy demonstrated urinary extravasation in a patient with acute anuria in whom early sequential imaging showed no abnormal extrarenal radionuclide accumulation.

  19. Imaging human melanoma using a novel Tc-99m-labeled lactam bridge-cyclized alpha-MSH peptide.

    PubMed

    Liu, Liqin; Xu, Jingli; Yang, Jianquan; Feng, Changjian; Miao, Yubin

    2016-10-01

    In this study, the human melanoma targeting property of (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex {hydrazinonicotinamide-8-aminooctanoic acid-Nle-c[Asp-His-DPhe-Arg-Trp-Lys]-CONH2} was determined in M21 human melanoma-xenografts to demonstrate its potential for human melanoma imaging. The IC50 value of HYNIC-AocNle-CycMSHhex was 0.48±0.01nM in M21 human melanoma cells (1281receptors/cell). The M21 human melanoma uptake of (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex was 4.03±1.25, 3.26±1.23 and 3.36±1.48%ID/g at 0.5, 2 and 4h post-injection, respectively. Approximately 92% of injected dose cleared out the body via urinary system at 2h post-injection. (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex showed high tumor/blood, tumor/muscle and tumor/skin uptake ratios after 2h post-injection. The M21 human melanoma-xenografted tumor lesions were clearly visualized by SPECT/CT using (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex as an imaging probe at 2h post-injection. Overall, (99m)Tc(EDDA)-HYNIC-AocNle-CycMSHhex exhibited favorable human melanoma imaging property, highlighting its potential as an imaging probe for human metastatic melanoma detection. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Technetium-99 conjugated with methylene diphosphonate inhibits receptor activator of nuclear factor-κB ligand-induced osteoclastogenesis.

    PubMed

    Gong, Wei; Dou, Huan; Liu, Xianqin; Sun, Lingyun; Hou, Yayi

    2012-10-01

    1. In the present study, we investigated the effects of technetium-99 conjugated with methylene diphosphonate ((99)Tc-MDP), an agent used in radionuclide therapy, on receptor activator of nuclear factor-κB ligand (RANKL)-induced osteoclastogenesis and explored the underlying mechanisms. 2. The murine macrophage cell line RAW264.7 and bone marrow-derived-macrophages from C57BL/6 mice (BMM) were used as models for osteoclastogenesis in vitro. The expression of some key factors in RANKL (50 ng/mL)-induced osteoclastogenesis in RAW264.7 cells was investigated by flow cytometry and real-time reverse transcription-polymerase chain reaction (RT-PCR). To detect multinucleated osteoclast formation, RAW264.7 cells were induced with RANKL for 4 days, whereas BMM were induced by 50 ng/mL RANKL and 20 ng/mL macrophage colony-stimulating factor for 7 days, before being stained with tartrate-resistant acid phosphatase. 3. Osteoclastogenesis was evaluated using the osteoclast markers CD51, matrix metalloproteinase (MMP)-9 and cathepsin K. At 0.01 μg/mL, (99)Tc-MDP significantly inhibited RANKL-induced osteoclastogenesis without any cytotoxicity. In addition, (99)Tc-MDP abolished the appearance of multinucleated osteoclasts. 4. Real-time RT-PCR analysis of transcription factor expression revealed that (99)Tc-MDP inhibited the expression of c-Fos and nuclear factor of activated T cells. In addition, (99)Tc-MDP inhibited the expression of the inflammatory factors interleukin (IL)-6, tumour necrosis factor-α and IL-1β. Finally, (99)Tc-MDP inhibited the activation of mitogen-activated protein kinases in RAW264.7 cells following RANKL stimulation. 5. In conclusion, (99)Tc-MDP possesses anti-osteoclastogenic activity against RANKL-induced osteoclast formation. © 2012 The Authors Clinical and Experimental Pharmacology and Physiology © 2012 Wiley Publishing Asia Pty Ltd.

  1. Structural and Perfusion Abnormalities of Brain on MRI and Technetium-99m-ECD SPECT in Children With Cerebral Palsy: A Comparative Study.

    PubMed

    Rana, Kamer Singh; Narwal, Varun; Chauhan, Lokesh; Singh, Giriraj; Sharma, Monica; Chauhan, Suneel

    2016-04-01

    Cerebral palsy has traditionally been associated with hypoxic ischemic brain damage. This study was undertaken to demonstrate structural and perfusion brain abnormalities. Fifty-six children diagnosed clinically as having cerebral palsy were studied between 1 to 14 years of age and were subjected to 3 Tesla magnetic resonance imaging (MRI). Brain and Technetium-99m-ECD brain single-photon emission computed tomography (SPECT) scan. Male to female ratio was 1.8:1 with a mean age of 4.16 ± 2.274 years. Spastic cerebral palsy was the most common type, observed in 91%. Birth asphyxia was the most common etiology (69.6%). White matter changes (73.2%) such as periventricular leukomalacia and corpus callosal thinning were the most common findings on MRI. On SPECT all cases except one revealed perfusion impairments in different regions of brain. MRI is more sensitive in detecting white matter changes, whereas SPECT is better in detecting cortical and subcortical gray matter abnormalities of perfusion. © The Author(s) 2015.

  2. A comparison of rat SPECT images obtained using (99m)Tc derived from 99Mo produced by an electron accelerator with that from a reactor.

    PubMed

    Galea, R; Wells, R G; Ross, C K; Lockwood, J; Moore, K; Harvey, J T; Isensee, G H

    2013-05-07

    Recent shortages of molybdenum-99 ((99)Mo) have led to an examination of alternate production methods that could contribute to a more robust supply. An electron accelerator and the photoneutron reaction were used to produce (99)Mo from which technetium-99m ((99m)Tc) is extracted. SPECT images of rat anatomy obtained using the accelerator-produced (99m)Tc with those obtained using (99m)Tc from a commercial generator were compared. Disks of (100)Mo were irradiated with x-rays produced by a 35 MeV electron beam to generate about 1110 MBq (30 mCi) of (99)Mo per disk. After target dissolution, a NorthStar ARSII unit was used to separate the (99m)Tc, which was subsequently used to tag pharmaceuticals suitable for cardiac and bone imaging. SPECT images were acquired for three rats and compared to images for the same three rats obtained using (99m)Tc from a standard reactor (99)Mo generator. The efficiency of (99)Mo-(99m)Tc separation was typically greater than 90%. This study demonstrated the delivery of (99m)Tc from the end of beam to the end user of approximately 30 h. Images obtained using the heart and bone scanning agents using reactor and linac-produced (99m)Tc were comparable. High-power electron accelerators are an attractive option for producing (99)Mo on a national scale.

  3. Technetium-99m labeled red blood cells in the evaluation of hemangiosarcoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Joseph, U.A.; Jhingran, S.G.

    Imaging with Tc-99m labeled red blood cells (RBC) is increasingly being used in the detection of acute gastro-intestinal bleeding, especially in patients with intermittent bleeding. A patient is presented in whom the labeled RBC scan was helpful in the incidental discovery of a previously unsuspected probable angiosarcoma of the right femur and adjacent soft tissues of the right hip due to the blood pool or blush effect of the labeled cells. The labeled RBC scan also identified extravasation due to active gastrointestinal bleeding from a previously unknown angiosarcoma of the ascending colon. Thus, the Tc-99m labeled RBC scan was usefulmore » in simultaneously detecting extravasation and blood pool effect at two remote tumor sites in the same patient.« less

  4. In vitro cell studies of technetium-99m labeled RGD-HYNIC peptide, a comparison of tricine and EDDA as co-ligands.

    PubMed

    Su, Zi-Fen; He, Jiang; Rusckowski, Mary; Hnatowich, Donald J

    2003-02-01

    The level of alpha(V)beta(3) integrins on endothelial cells is elevated in angiogenesis. The high binding specificity to alpha(V)beta(3) integrins of peptides containing Arg-Gly-Asp (RGD) residues suggests that the radiolabeled RGD peptides may be useful as tumor specific imaging agents. In this research, cyclised peptides containing Arg-Gly-Asp (RGD) and Arg-Gly-Glu (RGE, as control) residues were conjugated with HYNIC and labeled with (99m)Tc. The goal was to evaluate the influence of co-ligand, either tricine or ethylenediamine-N,N'-diacetic acid (EDDA) on protein and integrin binding and on cellular uptake in culture. The n-octanol/water partition coefficient, binding to bovine serum albumin (BSA) and human umbilical vein endothelial (HUVE) cells, and cell lysate distributions of the radiolabeled peptides were evaluated. The co-ligands had a significant effect on the labeling efficiency of the HYNIC conjugates and on certain properties of the (99m)Tc complexes. The labeling efficiency with tricine was 10 fold higher and BSA binding was over 8 fold greater compared to EDDA. Both RGD labels showed higher (6 to 28 fold) binding to HUVE cells than that of the RGE labels, indicating binding specificity. After cell-lysis, only a small percentage of the total RGD label that accumulated in the cells was found bound to cellular proteins (9% of RGD/tricine and 5% of RGD/EDDA), implying that over 90% of the radiolabeled peptides were internalized for both radiolabeled RGDs. The number of the RGD molecules bound to proteins was estimated to be approximately three per cell, suggesting that only a small number of alpha(V)beta(3) integrin proteins are expressed on the cells. Apart from the differences in radiolabeling, the only important effect of substituting EDDA for tricine as co-ligand on the HYNIC-peptides was the lower degree of serum protein binding. In spite of the lower serum protein binding potential, in vivo tumor accumulation of the RGD/EDDA may not be improved

  5. [Regional blood flow and bone uptake of methylene-diphosphonate-technetium-99m].

    PubMed

    Vattimo, A; Martini, G; Pisani, M

    1983-05-30

    Sudeck's atrophy of the foot is an acute, patchy osteoporosis that, on bone scan, shows an increase in both bone blood flow and local bone uptake of bone-seeking radionuclides. The purpose of this study was to evaluate the relationship between bone uptake of 99mTc-MDP and local bone blood flow. In some patients with Sudeck's atrophy of one foot we measured local bone blood flow and bone uptake of 99mTc-MDP. External counting of radioactivity, with a count-rate of 1 second was performed for 60 minutes after i.v. injection of a known dose of 99mTc-MDP in some patients with Sudeck's atrophy of the foot. The regions of interest (ROI) were selected on the basis of a bone scan performed 24 hours earlier. We assumed that the data recorded during the first seconds (7-10) reflect local blood flow and the data at 60 minutes reflect the bone uptake. The ratio between the local blood flow in the involved and healthy foot was higher than the local bone uptake ratio. The ratio between bone uptake and local bone blood flow was higher in the normal foot than in the affected one. These results suggest that the bone avidity for bone-seeking radionuclides is lower in Sudeck's atrophy than in normal bone.

  6. Clinical translation of a PSMA inhibitor for 99mTc-based SPECT.

    PubMed

    Ferro-Flores, Guillermina; Luna-Gutiérrez, Myrna; Ocampo-García, Blanca; Santos-Cuevas, Clara; Azorín-Vega, Erika; Jiménez-Mancilla, Nallely; Orocio-Rodríguez, Emmanuel; Davanzo, Jenny; García-Pérez, Francisco O

    2017-05-01

    Prostate-specific membrane antigen (PSMA) is highly over-expressed in advanced prostate cancers. 68 Ga-labeled PSMA inhibitors (iPSMA) are currently used for prostate cancer detection by PET imaging. The availability of simple, efficient and reproducible radiolabeling procedures is essential for developing new SPECT radiopharmaceuticals for clinical translation. The aim of this research was to prepare 99m Tc-EDDA/HYNIC-Lys(Nal)-Urea-Glu ( 99m Tc-EDDA/HYNIC-iPSMA) obtained from lyophilized kit formulations and evaluate the in vitro and in vivo radiopharmaceutical binding to prostate cancer cells over-expressing PSMA, as well as the 99m Tc-EDDA/HYNIC-iPSMA normal biodistribution in humans and the preliminary uptake in patients with prostate cancer. 99m Tc labeling was performed by adding sodium pertechnetate solution and a 0.2M phosphate buffer (pH 7.0) to a lyophilized formulation containing HYNIC-iPSMA, EDDA, tricine, mannitol and stannous chloride. The radiochemical purity was evaluated by reversed-phase HPLC and ITLC-SG analyses. Stability studies in human serum were performed by size-exclusion HPLC. In vitro cell uptake was tested using prostate cancer cells (LNCaP) with blocked and non-blocked receptors. Biodistribution and tumor uptake were determined in LNCaP tumor-bearing nude mice with blocked and non-blocked receptors, and images were obtained using a micro-SPECT/CT. Whole-body images from three healthy men and two patients with histologically-confirmed prostate cancer (one of them with a previous 68 Ga-PSMA-617scan) were acquired at 1h and 3h after 99m Tc-EDDA/HYNIC-iPSMA administration with radiochemical purities of >98%. In vitro and in vivo studies showed high radiopharmaceutical stability in human serum, specific recognition for PSMA, high tumor uptake (10.22±2.96% ID/g at 1h) with rapid blood clearance and mainly kidney elimination. Preliminary images in patients demonstrated the ability of 99m Tc-EDDA/HYNIC-iPSMA to detect tumors and metastases of

  7. Direct comparison of solid-phase gastric emptying times assessed by means of a carbon isotope-labeled sodium acetate breath test and technetium Tc 99m albumin colloid radioscintigraphy in healthy cats.

    PubMed

    Schmitz, Silke; Götte, Birte; Borsch, Christian; Kunz, Clemens; Failing, Klaus; Neiger, Reto

    2014-07-01

    To directly compare solid-phase gastric emptying times assessed by means of a [(13)C]sodium acetate breath test ([(13)C]-SABT) and technetium Tc 99m albumin colloid radioscintigraphy ((99m)Tc-ACR) in healthy cats. 12 healthy cats. After ingestion of a test meal containing 50 mg of [(13)C]sodium acetate and 250 MBq of (99m)Tc-albumin colloid, each cat underwent simultaneous [(13)C]-SABT and (99m)Tc-ACR on 2 consecutive days. Breath samples and scintigrams were acquired at 30, 60, 90, 120, 150, 180, 210, 240, 300, 360, 480, and 600 minutes after meal ingestion. Quartiles of gastric emptying (25%, 50%, and 75%) were calculated for breath test analysis by use of the area under the curve of the (13)C:(12)C ratio. Quartiles of gastric emptying times were extrapolated from the scintigraphic findings by beans of nonlinear curve regression analysis. Mean ± SD gastric half-emptying (50%) times obtained with [(13)C]-SABT and (99m)Tc-ACR, were 239 ± 28 minutes and 276 ± 59 minutes, respectively. A 2-way repeated-measures ANOVA revealed that mean gastric emptying times determined with [(13)C]-SABT and (99m)Tc-ACR differed significantly. For the stages of gastric emptying, Pearson correlation between the 2 methods was good at 25% (r = 0.655) and weak at 50% (r = 0.588) and 75% (r = 0.566)of gastric emptying. Results indicated that the [(13)C]-SABT can be a valid alternative to (99m)Tc-ACR in healthy cats; it was easy to perform, was tolerated well by the cats, and had acceptable correlation to scintigraphic findings at gastric emptying of 25%, 50% and 75%. Studies in cats with delayed gastric emptying will be needed to verify the validity of the [(13)C]-SABT.

  8. The absorption of (99m)Tc-alendronate given by rectal route in rabbits.

    PubMed

    Asikoğlu, Makbule; Ozguney, Isik; Ozcan, Ipek; Orumlu, Oya; Guneri, Tamer; Koseoğlu, Kamil; Ozkilic, Hayal

    2008-01-01

    Alendronate sodium (ALD) is a bisphosphonate medication used in the treatment and prevention of osteoporosis. Absorption of ALD as oral formulation is very poor (0.5%-1%). Its bioavailability can decrease with food effect. It has some gastrointestinal adverse effects such as gastritis, gastric ulcer, and esophagitis. The aim of this study was to develop a rectal formulation of ALD as an alternative to oral route and to investigate the absorption of it by using gamma scintigraphy. For this reason, ALD was labeled with Technetium-99m ((99m)Tc) by direct method. The radiochemical characterization of the (99m)Tc-ALD was carried out by paper chromatography, thin layer chromatography, and electrophoresis methods. The labeling efficiency of (99m)Tc-ALD was found 99% without significant changes until 6 h postlabeling at room temperature. The rectal suppositories containing (99m)Tc-ALD were prepared by fusion method using polyethylene glycol (PEG) 1500. The (99m)Tc-labeled ALD suppositories were administrated to rabbits by rectal route. Serial scintigrams over all bodies of the rabbits were obtained at different time intervals using a gamma camera. We found that the rectal absorption of (99m)Tc-ALD from suppository formulation was possible. According to our results, this formulation of ALD can be suggested for the therapy of osteoporosis as an alternative route.

  9. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE PAGES

    Luksic, Steven A.; Kim, Dong Sang; Um, Wooyong; ...

    2018-03-02

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2∙2H 2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. Here, we postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Finally,more » additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  10. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO2∙2H2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with hexavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Additional studies are neededmore » to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from glass melt.« less

  11. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong Sang; Um, Wooyong

    Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2∙2H 2O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. Here, we postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generally accepted idea. Finally,more » additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  12. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong

    © 2018 Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2 ∙2H 2 O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generallymore » accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  13. Effect of Technetium-99 sources on its retention in low activity waste glass

    DOE PAGES

    Luksic, Steven A.; Kim, Dong-Sang; Um, Wooyong; ...

    2018-05-01

    © 2018 Small-scale crucible melting tests on simulated waste glass were performed with technetium-99 (Tc-99) introduced as different species in a representative low activity waste simulant. The glass saw an increase in Tc-99 retention when TcO 2 ∙2H 2 O and various Tc-minerals containing reduced tetravalent Tc were used compared to tests in which pertechnetate with heptavalent Tc was used. We postulate that the increase of Tc retention is likely caused by different reaction paths for Tc incorporation into glass during early stages of melting, rather than the low volatility of reduced tetravalent Tc compounds, which has been a generallymore » accepted idea. Additional studies are needed to clarify the exact mechanisms relevant to the effect of reduced Tc compounds on Tc incorporation into or volatilization from the glass melt.« less

  14. Functional discrepancy between two liver lobes after hemilobe biliary drainage in patients with jaundice and bile duct cancer: an appraisal using (99m)Tc-GSA SPECT/CT fusion imaging.

    PubMed

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Noda, Yoshihiro; Hata, Yasuhiro; Murata, Yoriko; Kozuki, Akihito; Tokumaru, Teppei; Nakamura, Toshio; Uka, Kiminori

    2014-11-01

    To determine the functional discrepancy between the two liver lobes using technetium 99m ((99m)Tc) diethylenetriamine-pentaacetic acid-galactosyl human serum albumin ( GSA diethylenetriamine-pentaacetic acid-galactosyl human serum albumin ) single photon emission computed tomography (SPECT)/computed tomography (CT) fusion imaging following preoperative biliary drainage and portal vein embolization ( PVE portal vein embolization ) in patients with jaundice who have bile duct cancer ( BDC bile duct cancer ). This retrospective study was approved by the institutional review board, with waiver of informed consent. Preoperative (99m)Tc- GSA diethylenetriamine-pentaacetic acid-galactosyl human serum albumin SPECT/CT fusion images from 32 patients with extrahepatic BDC bile duct cancer were retrospectively reviewed. Patients were classified into four groups according to the extent of biliary drainage and presence of a preoperative right PVE portal vein embolization : right lobe drainage group (right drainage), bilateral lobe drainage group (bilateral drainage), left lobe drainage group (left drainage), and left lobe drainage with right PVE portal vein embolization group (left drainage with right PVE portal vein embolization ). Percentage volume and percentage function were measured in each lobe using fusion imaging. The ratio between percentage function and percentage volume (the function-to-volume ratio) was calculated for each lobe, and the results were compared among the four groups. Statistical analysis was performed with Wilcoxon signed-rank tests and Mann-Whitney U tests. The median values for the function-to-volume ratio in the right drainage, bilateral drainage, left drainage, and left drainage with right PVE portal vein embolization group were 1.12, 1.05, 1.02, and 0.81 in the right lobe; and 0.51, 0.88, 0.96, and 1.17 in the left lobe. Significant differences in the function-to-volume ratio were observed among the four groups (right drainage vs bilateral

  15. Recruitment of 99m-technetium- or 111-indium-labelled polymorphonuclear leucocytes in experimentally induced pyogranulomas in lambs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guilloteau, L.; Pepin, M.; Pardon, P.

    1990-10-01

    The recruitment of polymorphonuclear leucocytes (PMNs) during the development of experimental pyogranulomas induced by Corynebacterium pseudotuberculosis was followed in nine male lambs by scintigraphic examination. Autologous blood PMNs were labelled with 99m-technetium or 111-indium and were re-injected intravenously into infected lambs. The functional properties of the labelled cells were monitored (1) in vitro by measuring their phagocytic and bactericidal activity against C. pseudotuberculosis and their chemotaxis under agarose, and (2) in vivo by following scintigraphically their capacity to accumulate in an inflammatory focus induced by intradermal injection of latex beads coated with Salmonella abortus equi lipopolysaccharide. Following inoculation of corynebacteriamore » into the right ear of lambs, radioactive foci were observed to be localized in the right ear and in the draining lymph nodes during the 4 days following inoculation. Histopathological examination performed 32 h after inoculation confirmed the intense accumulation of PMNs at these sites. With the exception of one animal, which presented visible foci in the neck 14 days postinoculation, no radioactive foci were observed during the later phases of experimental infection, despite the presence of multiple pyogranulomas which were confirmed by bacteriological examination after necropsy of the lambs. Histopathological examination of these lesions revealed layers of fibroblasts, lymphocytes, and macrophages surrounding a necrotic centre. The results of these studies suggest that the contribution of PMNs during the chronic phase of inflammation is considerably reduced in comparison with the acute inflammatory phase of the infectious process.« less

  16. Evaluating 99mTc Auger electrons for targeted tumor radiotherapy by computational methods.

    PubMed

    Tavares, Adriana Alexandre S; Tavares, João Manuel R S

    2010-07-01

    Technetium-99m (99mTc) has been widely used as an imaging agent but only recently has been considered for therapeutic applications. This study aims to analyze the potential use of 99mTc Auger electrons for targeted tumor radiotherapy by evaluating the DNA damage and its probability of correct repair and by studying the cellular kinetics, following 99mTc Auger electron irradiation in comparison to iodine-131 (131I) beta minus particles and astatine-211 (211At) alpha particle irradiation. Computational models were used to estimate the yield of DNA damage (fast Monte Carlo damage algorithm), the probability of correct repair (Monte Carlo excision repair algorithm), and cell kinetic effects (virtual cell radiobiology algorithm) after irradiation with the selected particles. The results obtained with the algorithms used suggested that 99mTc CKMMX (all M-shell Coster-Kroning--CK--and super-CK transitions) electrons and Auger MXY (all M-shell Auger transitions) have a therapeutic potential comparable to high linear energy transfer 211At alpha particles and higher than 131I beta minus particles. All the other 99mTc electrons had a therapeutic potential similar to 131I beta minus particles. 99mTc CKMMX electrons and Auger MXY presented a higher probability to induce apoptosis than 131I beta minus particles and a probability similar to 211At alpha particles. Based on the results here, 99mTc CKMMX electrons and Auger MXY are useful electrons for targeted tumor radiotherapy.

  17. Significance of functional hepatic resection rate calculated using 3D CT/(99m)Tc-galactosyl human serum albumin single-photon emission computed tomography fusion imaging.

    PubMed

    Tsuruga, Yosuke; Kamiyama, Toshiya; Kamachi, Hirofumi; Shimada, Shingo; Wakayama, Kenji; Orimo, Tatsuya; Kakisaka, Tatsuhiko; Yokoo, Hideki; Taketomi, Akinobu

    2016-05-07

    To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/(99m)Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making. We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and (99m)Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/(99m)Tc-GSA SPECT fusion images. In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 ± 19.9 and 44.5 ± 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P < 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of > 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 ± 0.19 vs 0.82 ± 0.18, P < 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade ≥ 3) occurred in 17 patients (29.8%). There was no case of surgery-related death. Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular

  18. Radiopharmaceutical considerations for using Tc-99m MAA in lung transplant patients.

    PubMed

    Ponto, James A

    2010-01-01

    To elucidate radiopharmaceutical considerations for using technetium Tc-99m albumin aggregated (Tc-99m MAA) in lung transplant patients and to establish an appropriate routine dose and preparation procedure. Tertiary care academic hospital during May 2007 to May 2009. Nuclear pharmacist working in nuclear medicine department. Radiopharmaceutical considerations deemed important for the use of Tc-99m MAA in lung transplant patients included radioactivity dose, particulate dose, rate of the radiolabeling reaction (preparation time), and final radiochemical purity. Evaluation of our initial 12-month experience, published literature, and professional practice guidelines provided the basis for establishing an appropriate dose and preparation procedure of Tc-99m MAA for use in lung transplant patients. Radiochemical purity at typical incubation times and image quality in subsequent lung transplant patients imaged during the next 12 months. Based on considerations of radioactivity dose, particulate dose, rate of the radiolabeling reaction (preparation time), and final radiochemical purity, a routine dose consisting of 3 mCi (111 MBq) and 100,000 particles of Tc-99m MAA for planar perfusion lung imaging of adult lung transplant patients was established as reasonable and appropriate. MAA kits were prepared with a more reasonable amount of Tc-99m and yielded high radiochemical purity values in typical incubation times. Images have continued to be of high diagnostic quality. Tc-99m MAA used for lung transplant imaging can be readily prepared with high radiochemical purity to provide a dose of 3 mCi (111 GBq)/100,000 particles, which provides images of high diagnostic quality.

  19. Technetium-99m diethylenetriaminepentaacetic acid radioaerosol scintigraphy in organophosphate induced pulmonary toxicity: experimental study.

    PubMed

    Yavuz, Yucel; Kaya, Eser; Yurumez, Yusuf; Sahin, Onder; Bas, Orhan; Fidan, Huseyin; Sezer, Murat

    2008-09-01

    The aim of this experimental study was to investigate pathological signs of lung damages caused by acute organophosphate (OP) poisoning by using Tc-99m DTPA radioaerosol scintigraphy and histopathological investigation. Fourteen rabbits were divided into two equal groups (n = 7). Group 1 (control group) received normal saline (same volume of fenthion, 2 ml/kg) via orogastric tube. Group 2 (OP toxicity group) received 150 mg/kg of fenthion (diluted fenthion, 2 ml/kg) via orogastric tube. Six hours later, Tc-99m-DTPA aerosol inhalation lung scintigraphy was performed in both groups. Then all rabbits were anesthetized with ketamine hydrochloride (35 mg/kg, i.p.) and xysilazine (5 mg/kg, i.p.), and sacrificed by intracardiac blood discharge. The lungs were then removed. There was a significant difference in T1/2 values of Tc-99m DTPA clearance between control group and OP toxicity group (p = 0.04). Intraparenchymal vascular congestion and thrombosis, intraparenchymal hemorrhage, respiratory epithelial proliferation, number of macrophages in the alveolar, and bronchial lumen, alveolar destruction, emphysematous changes, and bronchoalveolar hemorrhage scores were significantly higher in the rabbits exposed to OP compared with the control group (p < 0.05). This study showed that OP toxicity caused a decrease in the alveolar clearance. Tc-99m DTPA radioaerosol inhalation lung scintigraphy was found to be a sensitive determination of acute lung damage in OP poisoning.

  20. 2-Phenylbenzothiazole conjugated with cyclopentadienyl tricarbonyl [CpM(CO)3] (M = Re, (99m)Tc) complexes as potential imaging probes for β-amyloid plaques.

    PubMed

    Jia, Jianhua; Cui, Mengchao; Dai, Jiapei; Liu, Boli

    2015-04-14

    Technetium-99m-labeled cyclopentadienyl tricarbonyl complexes conjugated with the 2-phenylbenzothiazole binding motif were synthesized. The rhenium surrogates , , and were demonstrated to have moderate to high affinities for Aβ1-42 aggregates with Ki values of 142, 76, 64 and 24 nM, respectively. During the fluorescence staining of brain sections of transgenic mice and patients with Alzheimer's disease, these rhenium complexes demonstrated perfect and intense labeling of Aβ plaques. Moreover, in in vitro autoradiography, (99m)Tc-labeled complexes clearly detected β-amyloid plaques on sections of brain tissue from transgenic mice, which confirmed the sufficient affinity of these tracers for Aβ plaques. However, these compounds did not show desirable properties in vivo, especially showing poor brain uptake (below 0.5% ID g(-1)), which will hinder the further development of these tracers as brain imaging agents. Nonetheless, it is encouraging that these (99m)Tc-labeled complexes designed by a conjugate approach displayed sufficient affinities for Aβ plaques.

  1. Assessment of antioxidative ability in brain: Imaging of glutathione localization with technetium-99M meso-hexamethyl propyleneamine oxime

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sasaki, T.; Toyama, H.; Oda, K.

    1994-05-01

    An oxidative stress is postulated to be important in tissue injury after ischemia and reperfusion, inflammation, aging and various disease. Glutathione (GSH), one of the major antioxidants in the brain, is presumed to be responsible for the metabolism and retention of [Tc-99m] HM-PAO. In order to visualize the regional localization of GSH in the brain, the relationship between the concentrations of tissue GSH and uptake of [Tc-99m] meso-HM-PAO and [Tc-99m] d,l-HM-PAO was studied in mice. Increasing load of diethyl maleate (DEM), a reducing agent of GSH and several other thiols, before [Tc-99m] meso-HM-PAO injection, led to a dose dependent decreasemore » of GSH and [Tc-99m] meso-HM-PAO. At the highest dose of loaded DEM, the uptake of [Tc-99m] meso-HM-PAO in the brain was decreased to 20-30% of the control. In contrast, pretreatment with DEM did little affect the [Tc-99m] d,l-HM-PAO uptake. To elucidate the retention mechanism of [Tc-99m] HM-PAO in brain, we studied the in vitro interactions of [Tc-99m] meso-HMPAO and [Tc-99m] d,l-HM-PAO with GSH, ascorbate and cysteine by measuring octanol-extractable radioactivity, which is remaining intact [Tc-99m] HM-PAO, as a function of incubation period. The disappearance raw of [Tc-99m] meso-HMPAO and [TC-99m] d,l-HM-PAO were 0.18 and 0.96%/min, respectively. Either meso or d,l-isomer did not interact with ascorbate or cysteine. This result suggested that the retention mechanism of [Tc-99m] meso- and d,l-isomers in brain was related to their specific interaction with GSH, and did not related to non-specific interaction with various thiols or other reducing agents. This extremely high reaction rate of [Tc-99m] d,l-HM-PAO with GSH could explain the capability of a small amount of GSH to trap [Tc-99m] d,l-HM-PAO in maximum DEM loading. These results indicated that [Tc-99m] meso-HMPAO would be suitable to image the concentration of GSH in the brain, as opposed d,l-isomer that images blood flow.« less

  2. Update on radionuclide imaging in hepatobiliary disease. [/sup 99m/Tc-labelled acetanilide iminodracetic acid analogues

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosenthall, L.

    1981-05-01

    The recent introduction of technetium Tc 99m-labeled acetanilide iminodiacetic acid (/sup 99m/Tc-IDA) analogues has facilitated the clincal study of the bile flow pathways. A variety of /sup 99m/Tc-IDA derivaties are under investigation. Basically all are metabolized by the hepatocyte and immediately thereafter excreted unconjugated into the biliary tract. Of the various derivatives tested, e.g., dimethyl (lidofenin), diethyl, paraisopropyl (iprofenin), parabutyl (butilfenin), and diisopropyl (disofenin), the last named is the best universal agent at this time. By serial liver imaging the patency of the cystic duct and the integrity of altered cholangiointestinal anatomy can be assessed, leakage of bile and gastricmore » reflux can be disclosed, and medical and surgical jaundice can be distinguished.« less

  3. Does the Clearance of Inhaled (99m)Tc-Sestamibi Correlate with Multidrug Resistance Protein 1 Expression in the Human Lung?

    PubMed

    Mohan, Hosahalli K; Routledge, Thomas; Cane, Paul; Livieratos, Lefteris; Ballinger, James R; Peters, Adrien M

    2016-09-01

    Purpose To examine the relation between the lung elimination rate of inhaled technetium 99m ((99m)Tc)-sestamibi and immunohistochemical expression of bronchopulmonary multidrug resistance protein 1 (MRP1) and permeability glycoprotein (P-gp) and assess the repeatability of the inhaled (99m)Tc-sestamibi clearance technique. Materials and Methods (99m)Tc-sestamibi is a known substrate for P-gp and MRP1, which are established cellular drug efflux transporters. The elimination rate of (99m)Tc-sestamibi from the lungs after inhalation as an aerosol has been hypothesized to be regulated by expression of these transporters. Institutional ethics committee approval was received for this prospective study. Written informed consent was obtained from all participants. The clearance of inhaled (99m)Tc-sestamibi from the lungs of 13 patients due to undergo surgery for primary lung cancer (five of 13) or spontaneous pneumothorax (eight of 13) was estimated after dynamic imaging of the lungs during a period of 40 minutes. The time taken to clear 50% of inhaled sestamibi (T1/2) was compared with a semiquantitative immunohistochemical assessment (grade 0-3) of MRP1 and P-gp expression in the lung by using parametric and nonparametric tests. The study was repeated in five participants to assess the repeatability of the technique by using a Bland Altman analysis method. Results MRP1 expression was seen in 12 of 13 patients, while P-gp expression was seen in only two. The mean (99m)Tc-sestamibi elimination rate was faster in patients (n = 6) with low levels of MRP1 expression (grade 0-1) and mean T1/2 of 105 minutes ± 20 (standard deviation), compared with those with higher levels of MRP1 expression (grade 2-3, n = 7) and mean T1/2 of 149 minutes ± 28 (P = .008). Bland-Altman analysis revealed excellent agreement between test and retest values. Conclusion Inhaled (99m)Tc-sestamibi clearance study is a repeatable technique demonstrating significant correlation with MRP1 expression in

  4. Development and Pharmacological Evaluation of New Bone-Targeted (99m)Tc-Radiolabeled Bisphosphonates.

    PubMed

    Makris, George; Tseligka, Eirini D; Pirmettis, Ioannis; Papadopoulos, Minas S; Vizirianakis, Ioannis S; Papagiannopoulou, Dionysia

    2016-07-05

    A novel bisphosphonate, 1-(3-aminopropylamino)ethane-1,1-diyldiphosphonic acid (3), was coupled to the tridentate chelators di-2-picolylamine, 2-picolylamine-N-acetic acid, iminodiacetic acid, 3-((2-aminoethyl)thio)-3-(1H-imidazol-4-yl)propanoic acid, and 2-((2-carboxyethyl)thio)-3-(1H-imidazol-4-yl)propanoic acid to form ligands 6, 9, 11, 15, and 19, respectively. Organometallic complexes of the general formula [Re/(99m)Tc(CO)3(κ(3)-L)] were synthesized, where L denotes ligand 6, 9, 11, 15, or 19. The rhenium complexes were prepared at the macroscopic level and characterized by spectroscopic methods. The technetium-99m organometallic complexes were synthesized in high yield and were identified by comparative reversed-phase HPLC with their Re analogues. The (99m)Tc tracers were stable in vitro and exhibited binding to hydroxyapatite. In biodistribution studies, all of the (99m)Tc complexes exhibited high bone uptake superior to that of 25, which is the directly (99m)Tc-labeled bisphosphonate 3, and comparable to that of (99m)Tc-methylene diphosphonate ((99m)Tc-MDP). The tracers [(99m)Tc(CO)3(6)] (26), [(99m)Tc(CO)3(9)] (27), [(99m)Tc(CO)3(11)] (28), and [(99m)Tc(CO)3(15)] (29) exhibited higher bone/blood ratios than (99m)Tc-MDP. 26 had the highest bone uptake at 1 h p.i. The new bisphosphonates showed no substantial growth inhibitory capacity in PC-3, Saos-2, and MCF-7 established cancer cell lines at low concentrations. Incubation of 26 with the same cancer cell lines indicated a rapid and saturated uptake. The promising properties of 26-29 indicate their potential for use as bone-imaging agents.

  5. Synthesis of Tc-99m labeled 1,2,3-triazole-4-yl c-met binding peptide as a potential c-met receptor kinase positive tumor imaging agent.

    PubMed

    Kim, Eun-Mi; Joung, Min-Hee; Lee, Chang-Moon; Jeong, Hwan-Jeong; Lim, Seok Tae; Sohn, Myung-Hee; Kim, Dong Wook

    2010-07-15

    The mesenchymal-epithelial transition factor (c-Met), which is related to tumor cell growth, angiogenesis and metastases, is known to be overexpressed in several tumor types. In this study, we synthesized technetium-99m labeled 1,2,3-triazole-4-yl c-Met binding peptide (cMBP) derivatives, prepared by solid phase peptide synthesis and the 'click-to-chelate' protocol for the introduction of tricarbonyl technetium-99m, as a potential c-Met receptor kinase positive tumor imaging agent, and evaluated their in vitro c-Met binding affinity, cellular uptake, and stability. The (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12, [(99m)Tc(CO)(3)]13, and [(99m)Tc(CO)(3)]14) were prepared in 85-90% radiochemical yields. The cold surrogate cMBP derivatives, [Re(CO)(3)]12, [Re(CO)(3)]13, and [Re(CO)(3)]14, were shown to have high binding affinities (0.13 microM, 0.06 microM, and 0.16 microM, respectively) to a purified cMet/Fc chimeric recombinant protein. In addition, the in vitro cellular uptake and inhibition studies demonstrated the high specific binding of these (99m)Tc labeled cMBP derivatives ([(99m)Tc(CO)(3)]12-14) to c-Met receptor positive U87MG cells. 2010 Elsevier Ltd. All rights reserved.

  6. Fab(nimotuzumab)-HYNIC-99mTc: Antibody Fragmentation for Molecular Imaging Agents.

    PubMed

    Calzada, Victoria; García, María Fernanda; Alonso-Martínez, Luis Michel; Camachoc, Ximena; Goicochea, Enzo; Fernández, Marcelo; Castillo, Abmel Xiques; Díaz-Miqueli, Arlhee; Iznaga-Escobar, Normando; Montaña, René Leyva; Alonso, Omar; Gambini, Juan Pablo; Cabral, Pablo

    2016-01-01

    Finally, fast blood clearance nimotuzumab is a humanized monoclonal antibody that recognise, with high specific affinity, the epidermal growth factor receptor (EGF-R) which play an important role in the growth process associated with many solid tumors. In this work, the whole antibody was digested with papain in order to generate a Fab fragment, derivatized with NHS-HYNIC-Tfa and radiolabel with technetium-99m (99mTc) as a potential agent of molecular imaging of cancer. Both, whole and fragment radiolabels were in-vivo and in-vitro characterized. Radiolabeling conditions with Tricine as coligand and quality controls were assessed to confirm the integrity of the labeled fragment. Biodistribution and imaging studies in normal and spontaneous adenocarcinoma mice were performed at different times to determine the in-vivo characteristics of the radiolabel fragment. Tumor localization was visualized by conventional gamma camera imaging studies, and the results were compared with the whole antibody. Also, an immunoreactivity assay was carried out for both. The results showed clearly the integrity of the nimotuzumab fragment and the affinity by the receptor was verified. Fab(nimotuzumab)-HYNIC was obtained with high purity and a simple strategy of radiolabeling was performed. Finally, a fast blood clearance was observed in the biodistribution studies increasing the tumor uptake of Fab(nimotuzumab)- HYNIC-99mTc over time, with tumor/muscle ratios of 3.81 ± 0.50, 5.16 ± 1.97 and 6.32 ± 1.98 at 1 h, 4 h and 24 h post injection. Urinary excretion resulted in 32.89 ± 3.91 %ID eliminated at 24 h. Scintigraphy images showed uptake in the tumor and the activity in non-target organs was consistent with the biodistribution data at the same time points. Hence, these preliminary results showed important further characteristic of Fab(nimotuzumab)-HYNIC-99mTc as a molecular imaging agent of cancer.

  7. Technetium-99m tetrofosmin rest/stress myocardial SPET with a same-day 2-hour protocol: comparison with coronary angiography. A Spanish-Portuguese multicentre clinical trial.

    PubMed

    Montz, R; Perez-Castejón, M J; Jurado, J A; Martín-Comín, J; Esplugues, E; Salgado, L; Ventosa, A; Cantinho, G; Sá, E P; Fonseca, A T; Vieira, M R

    1996-06-01

    Technetium-99m tetrofosmin (Myoview) has unique properties for myocardial perfusion imaging very early after injection of the tracer. We used a very short same-day rest/stress protocol, to be performed within 2 h and evaluated its diagnostic accuracy. The study included 144 patients from seven Spanish and four Portuguese centres with a diagnosis of uncomplicated coronary artery disease (CAD); 78 patients (54%) had no history of prior myocardial infarction. Patients were injected with 99mTc-tetrofosmin at rest and /=50%) was achieved with a sensitivity of 64% for the left anterior descending artery, 49% for the left circumflex artery and 86% for the right coronary artery, and an accuracy of 71%, 72% and 73% respectively. Concordance of SPET and CA was 62% for single-vessel disease and 68% for multivessel disease. In conclusion, this Spanish-Portuguese multicentre clinical trial confirmed, in a considerable number of patients who underwent coronary angiography, the feasibility of 99mTc tetrofosmin (Myoview) rest/stress myocardial SPET using a very short protocol (2 h).

  8. Rhenium and technetium tricarbonyl, {M(CO)3} (+) (M = Tc, Re), binding to mammalian metallothioneins: new insights into chemical and radiopharmaceutical implications.

    PubMed

    Lecina, Joan; Palacios, Òscar; Atrian, Sílvia; Capdevila, Mercè; Suades, Joan

    2015-04-01

    This paper deals with the binding of the four mammalian metallothioneins (MTs) to the organometallic metal fragment {fac-M(CO)3}(+) (M = (99)Tc, Re), which is highly promising for the preparation of second-generation radiopharmaceuticals. The study of the transmetallation reaction between zinc and rhenium in Zn7-MT1 by means of UV-vis and CD spectroscopy demonstrated the incorporation of the {fac-Re(CO)3}(+) fragment to the MTs. This reaction should be performed at 70 °C to accelerate the reaction rate, a result that is consistent with the reported reactivity of the rhenium fragment. ESI-TOF MS demonstrated the formation of mixed-metal species as Zn6,{Re(CO)3}-MT, Zn6,{Re(CO)3}2-MT, and Zn5,{Re(CO)3}3-MT, as well as the different reactivity of the four MT isoforms. Hence, Zn-MT3 showed the highest reactivity, in agreement with its high Cu-thionein character, whereas Zn-MT2 exhibited the lowest reactivity, in line with its high Zn-thionein character. The reactivity of the Zn-loaded forms of MT1 and MT4 is intermediate between those of MT3 and MT2. The study of the binding of the {fac-(99)Tc(CO)3}(+) fragment to MTs showed a significant and very interesting different reactivity in relation to rhenium. The transmetallation reaction is much more effective with technetium than with rhenium and significant amounts of mixed Zn x ,{(99)Tc(CO)3} y -MT species were formed with the four MT isoforms whereas only MT3 rendered similar amounts of rhenium derivatives. The results obtained in this study support the possible use of technetium for labelling mammalian metallothioneins and also for possible radiopharmaceutical applications.

  9. Candidate Low-Temperature Glass Waste Forms for Technetium-99 Recovered from Hanford Effluent Management Facility Evaporator Concentrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ding, Mei; Tang, Ming; Rim, Jung Ho

    Alternative treatment and disposition options may exist for technetium-99 (99Tc) in secondary liquid waste from the Hanford Direct-Feed Low-Activity Waste (DFLAW) process. One approach includes development of an alternate glass waste form that is suitable for on-site disposition of technetium, including salts and other species recovered by ion exchange or precipitation from the EMF evaporator concentrate. By recovering the Tc content from the stream, and not recycling the treated concentrate, the DFLAW process can potentially be operated in a more efficient manner that lowers the cost to the Department of Energy. This report provides a survey of candidate glass formulationsmore » and glass-making processes that can potentially incorporate technetium at temperatures <700 °C to avoid volatilization. Three candidate technetium feed streams are considered: (1) dilute sodium pertechnetate loaded on a non-elutable ion exchange resin; (2) dilute sodium-bearing aqueous eluent from ion exchange recovery of pertechnetate, or (3) technetium(IV) oxide precipitate containing Sn and Cr solids in an aqueous slurry. From the technical literature, promising candidate glasses are identified based on their processing temperatures and chemical durability data. The suitability and technical risk of three low-temperature glass processing routes (vitrification, encapsulation by sintering into a glass composite material, and sol-gel chemical condensation) for the three waste streams was assessed, based on available low-temperature glass data. For a subset of candidate glasses, their long-term thermodynamic behavior with exposure to water and oxygen was modeled using Geochemist’s Workbench, with and without addition of reducing stannous ion. For further evaluation and development, encapsulation of precipitated TcO2/Sn/Cr in a glass composite material based on lead-free sealing glasses is recommended as a high priority. Vitrification of pertechnetate in aqueous anion exchange eluent

  10. Synthesis and evaluation of a 99mTc-labeled tubulin-binding agent for tumor imaging.

    PubMed

    Erfani, Mostafa; Shamsaei, Mojtaba; Mohammadbaghery, Faiyaz; Shirmardi, Seyed Pezhman

    2014-05-30

    Cholchicine and its derivatives are very potent tubulin-binding compounds and can be used as a potential tumor targeting agents. In this study, colchicine was labeled with (99m) Tc via hydrazinonicotinic acid (HYNIC) and was investigated further. HYNIC/cholchicine was synthesized and labeling with (99m)Tc was performed at 95 °C for 15 min and radiochemical analysis included HPLC method. The stability of radiconjugate was checked in the presence of human serum at 37 °C up to 24 h. Biodistribution was studied in breast tumor-bearing mice. Labeling yield of 95.8 ± 0.54% was obtained corresponding to a specific activity of 54 MBq/µmol. Radioconjugate showed good stability in the presence of human serum. Biodistribution studies in tumor-bearing mice showed that (99m) Tc/HYNIC/colchicine conjugate accumulated in tumor with good uptake (3.17 ± 0.14% g/g at 1 h post-injection). The radioconjugate was cleared fast from normal organs and showed clearance through urinary and hepatobiliary systems with accumulation of activity in kidneys and intestine. This radioconjugate may be useful to assess the presence of tumor by imaging. Copyright © 2014 John Wiley & Sons, Ltd.

  11. Comparison of 99mTc-HYNIC-TOC and HYNIC-TATE octreotide scintigraphy with FDG PET and 99mTc-MIBI in local recurrent or distant metastatic thyroid cancers.

    PubMed

    Sager, Sait; Kabasakal, Levent; Halac, Metin; Maecke, Helmut; Uslu, Lebriz; Önsel, Çetin; Kanmaz, Bedii

    2013-05-01

    There have been various studies for early diagnosis of local recurrent or distant metastatic thyroid cancers. The aim of this study is to evaluate the clinical utility of 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE, octreotide derivatives, to detect recurrences or distant metastases in 131I-negative thyroglobulin positive thyroid cancer patients and to compare the lesions with FDG PET and 99mTc-MIBI studies in the same patient group. Twenty differentiated thyroid cancer patients, 7 male and 13 female, mean age 54.6 ± 15.3 (range 13-78 years), were included in this study. Eighteen patients had papillary thyroid cancer and 2 had follicular thyroid cancer. Fifteen patients received HYNIC-TOC and 5 patients received HYNIC-TATE as a radiopharmaceutical. All patients underwent whole-body scan 1 and 4 hours after injection of octreotide derivatives and SPECT imagings were performed from the suspicious sites. The lesions that were seen in 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE studies were compared with 99mTc-MIBI and FDG-PET studies. Among 99mTc-HYNIC-TOC and 99mTc-HYNIC-TATE scintigraphies, 15 patient studies were evaluated as true positive (75%) and 5 were false negative (25%). The total number of lesions in octreotide scintigraphy was 48 in 20 patients. Of 20 patients, 19 had FDG-PET study, 15 of them were evaluated as true positive (78.9%), and 4 them were evaluated as false negative (21.1%). Total number of lesions in FDG PET was 74. 99mTc-MIBI study was positive in 11 patients (55%) and negative in 9 patients (45%). Total number of lesions in 99mTc-MIBI was 25. Technetium-labeled somatostatin receptor scintigraphy analogues HYNIC-TOC and HYNIC-TATE are useful imaging alternatives in somatostatin receptor expressing thyroid cancer patients. Radiolabeling is easy and they are readily available for routine use.

  12. Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shi, Tujin; Sun, Xuefei; Gao, Yuqian

    2013-07-05

    We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50-100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion and the multiplexing potential of this technique. Limits of quantification (LOQs) at low ng/mL levels with a medianmore » CV of ~12% were achieved for proteins spiked into human female serum using as little as 2 µL serum. PRISM-SRM provided up to ~1000-fold improvement in the LOQ when compared to conventional SRM measurements. Multiplexing capability of PRISM-SRM was also evaluated by two sets of serum samples with 6 and 21 target peptides spiked at the low attomole/µL levels. The results from SRM measurements for pooled or post-concatenated samples were comparable to those obtained from individual peptide fractions in terms of signal-to-noise ratios and SRM peak area ratios of light to heavy peptides. PRISM-SRM was applied to measure several ng/mL-level endogenous plasma proteins, including prostate-specific antigen, in clinical patient sera where correlation coefficients > 0.99 were observed between the results from PRISM-SRM and ELISA assays. Our results demonstrate that PRISM-SRM can be successfully used for quantification of low-abundance endogenous proteins in highly complex samples. Moderate throughput (50 samples/week) can be achieved by applying the post-concatenation or fraction multiplexing strategies. We anticipate broad applications for targeted PRISM

  13. Method and kit for the selective labeling of red blood cells in whole blood with TC-99M

    DOEpatents

    Srivastava, Suresh C.; Babich, John W.; Straub, Rita; Richards, Powell

    1988-01-01

    Disclosed herein are a method and kit for the preparation of .sup.99m Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available therein for the reduction of technetium.

  14. Tc-99m imaging in thyroidectomized differentiated thyroid cancer patients immediately before I-131 treatment.

    PubMed

    Tsai, Chi-Jung; Cheng, Cheng-Yi; Shen, Daniel Hueng-Yuan; Kuo, Shou Jen; Wang, Lien-Yen; Lee, Chiang-Hsuan; Wang, Jhi-Joung; Chang, Ming-Che; Huang, Wen-Sheng

    2016-02-01

    The aim of this study was to evaluate the clinical role of technetium-99m pertechnetate (Tc-99m) imaging in thyroidectomized differentiated thyroid cancer patients immediately before radioiodine-131 (I-131) treatment (Tx). Eighty-six consecutive post-total-thyroidectomy patients (15 men, 71 women; mean age: 46.8 years) with pathologically diagnosed differentiated thyroid cancer were retrospectively studied. Tc-99m imaging immediately before I-131 Tx using both patient-based and lesion-based measurements were analyzed and were further compared with those of post-Tx I-131 whole-body scans. For patients with unequivocally positive Tc-99m uptake, the sensitivity was 77% (patient-based) and 59% (site-based). The positive predictive value (PPV) was 100% for both patient-based and site-based measurements. If equivocal Tc-99m uptake was counted as positive, the sensitivity was 83 and 67%, and the PPV was 100 and 99% for patient-based and site-based measurements, respectively. (a) To increase sensitivity yet maintaining high PPV, equivocal Tc-99m uptake should be considered a positive finding. (b) The nearly 100% PPV of Tc-99m imaging immediately before I-131 Tx for remnant detection suggests that Tc-99m imaging not only serves as an alternative to low-dose I-131 scanning in the low-risk post-thyroidectomy patients but also provides a clue for the subsequent I-131 therapeutic dosage and even for the outcome prediction.

  15. Impact of Gate 99mTc DTPA GFR, Serum Creatinine and Urea in Diagnosis of Patients with Chronic Kidney Failure

    PubMed Central

    Miftari, Rame; Nura, Adem; Topçiu-Shufta, Valdete; Miftari, Valon; Murseli, Arbenita; Haxhibeqiri, Valdete

    2017-01-01

    Aim: The aim of this study was determination of validity of 99mTcDTPA estimation of GFR for early detection of chronic kidney failure Material and methods: There were 110 patients (54 males and 56 females) with kidney disease referred for evaluation of renal function at UCC of Kosovo. All patients were included in two groups. In the first group were included 30 patients confirmed with renal failure, whereas in the second group were included 80 patients with other renal disease. In study were included only patients with ready results of creatinine, urea and glucose in the blood serum. For estimation of GFR we have used the Gate GFR DTPA method. The statistical data processing was conducted using statistical methods such as arithmetic average, the student t-test, percentage or rate, sensitivity, specificity and accuracy of the test. Results: The average age of all patients was 36 years old. The average age of female was 37 whereas of male 35. Patients with renal failure was significantly older than patients with other renal disease (p<0.005). Renal failure was found in 30 patients (27.27%). The concentration of urea and creatinine in blood serum of patients with renal failure were significantly higher than in patients with other renal disease (P< 0.00001). GFR in patients with renal failure were significantly lower than in patients with other renal disease, 51.75 ml/min (p<0.00001). Sensitivity of uremia and creatininemia for detection of renal failure were 83.33%, whereas sensitivity of 99mTcDTPA GFR was 100%. Specificity of uraemia and creatininemia were 63% whereas specificity of 99mTcDTPA GFR was 47.5%. Diagnostic accuracy of blood urea and creatinine in detecting of renal failure were 69%, whereas diagnostic accuracy of 99mTcDTPA GFR was 61.8%. Conclusion: Gate 99mTc DTPA scintigraphy in collaboration with biochemical tests are very sensitive methods for early detection of patients with chronic renal failure. PMID:28883673

  16. Method and kit for the selective labeling of red blood cells in whole blood with Tc-99m

    DOEpatents

    Srivastava, S.C.; Babich, J.W.; Straub, R.; Richards, P.

    1988-07-05

    Disclosed herein are a method and kit for the preparation of [sup 99m]Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available for the reduction of technetium. No Drawings

  17. Technetium-99m-HMPAO as a marker of chemical and irradiation lung injury: Experimental and clinical investigations

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Suga, Kazuyoshi; Uchisako, Hiromichi; Nishigauchi, Kazuya

    1994-09-01

    The authors evaluated the ability of {sup 99m}Tc-hexamethylpropyleneamine oxime ({sup 99m}Tc-HMPAO) to serve as a sensitive marker of lung injury. Two experiment rabbit models of minimal lung injury were designed using injections of a low dose (0.05 ml/kg) of oleic acid or 50 Gy of irradiation. In addition, they clinically investigated whether patients who received chemotherapy (n = 14) or radiotherapy (n = 13) for lung cancer showed high uptake of {sup 99m}Tc-HMPAO in the lungs. Despite the minimal endothelial lesions visualized by electron microscopy (edematous changes and blebbing), in both animal models, the lungs showed high uptake of {supmore » 99m}Tc-HMPAO, which occurred rapidly within 1 min after injection. Clinically, the mean lung-to-liver ratio of {sup 99m}Tc-HMPAO activity in the patients who received chemotherapy (0.649{+-}0.185, p < 0.01) was significantly higher than that of the controls (n = 16; 0.387{+-}0.108), and all 12 patients who received more than 30 Gy of irradiation showed abnormal uptake in the irradiated lungs, despite the lack of abnormal opacities on chest CT. These findings suggest that {sup 99m}Tc-HMPAO has the potential to be a sensitive marker of chemical and irradiation lung injury. 53 refs., 5 figs., 3 tabs.« less

  18. Remote-loading labeling of liposomes with (99m)Tc-BMEDA and its stability evaluation: effects of lipid formulation and pH/chemical gradient.

    PubMed

    Li, Shihong; Goins, Beth; Phillips, William T; Bao, Ande

    2011-03-01

    Efficient, convenient, and stable radiolabeling plays a critical role for the monitoring of liposome behavior via either blood sampling, organ distribution, or noninvasive nuclear imaging. The direct labeling of liposome-carrying drugs without any prior modification undoubtedly is convenient and optimal for liposomal drug testing. In this article, we investigated the effect of various lipid formulations and pH/chemical gradients on the radiolabeling efficiency and entrapment stability of technetium-99m ((99m)Tc) remotely loaded into liposomes, using (99m)Tc-N,N-bis(2-mercaptoethyl)-N',N'-diethyl-ethylenediamine ((99m)Tc-BMEDA) complex. The tested liposomes either contained unsaturated lipid or possessed various surface charges. (99m)Tc could be efficiently loaded into various premanufactured liposomes containing either an ammonium sulfate pH, citrate pH, or glutathione (GSH) chemical gradient. (99m)Tc-entrapment stabilities of these liposomes in phosphate-buffered saline (PBS; pH 7.4) buffer at 25°C were mainly dependent on the pH/chemical gradient, but not lipid formulation. Stability sequence was ammonium sulfate pH-gradient>citrate pH-gradient>GSH-gradient. Stabilities of (99m)Tc-liposomes in 50% fetal bovine serum (FBS)/PBS (pH 7.4) buffer at 37°C are dependent on both lipid formulation and pH/chemical gradient. Specifically, (99m)Tc labeling of the ammonium sulfate pH-gradient liposomes were less stable in 50% FBS/PBS than in PBS, whereas noncationic liposomes with citrate pH- or GSH-gradient displayed higher stability, except that anionic citrate pH-gradient liposomes showed no stability difference in these two media. Cationic liposomes aggregated in 50% FBS/PBS, forming a new discrete fraction with larger particle sizes. These in vitro characterization results have indicated the optimism of using (99m)Tc-BMEDA for labeling pH/GSH gradient liposomes without the requirement of modifying lipid formulation for liposomal therapeutic-agent development.

  19. Altered [99mTc]Tc-MDP biodistribution from neutron activation sourced 99Mo.

    PubMed

    Demeter, Sandor; Szweda, Roman; Patterson, Judy; Grigoryan, Marine

    2018-01-01

    Given potential worldwide shortages of fission sourced 99 Mo/ 99m Tc medical isotopes there is increasing interest in alternate production strategies. A neutron activated 99 Mo source was utilized in a single center phase III open label study comparing 99m Tc, as 99m Tc Methylene Diphosphonate ([ 99m Tc]Tc-MDP), obtained from solvent generator separation of neutron activation produced 99 Mo, versus nuclear reactor produced 99 Mo (e.g., fission sourced) in oncology patients for which an [ 99m Tc]Tc-MDP bone scan would normally have been indicated. Despite the investigational [ 99m Tc]Tc-MDP passing all standard, and above standard of care, quality assurance tests, which would normally be sufficient to allow human administration, there was altered biodistribution which could lead to erroneous clinical interpretation. The cause of the altered biodistribution remains unknown and requires further research.

  20. Organ distribution of technetium-99m-labeled Corynebacterium parvum in normal and tumor-bearing mice

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Barth, R.F.; Singla, O.

    1978-01-01

    The distribution patterns were studied for /sup 99m/Tc-labeled Corynebacterium parvum in normal and tumor-bearing mice. C57BL/6 mice were given i.v., i.p., or s.c. injections of 250 ..mu..g of /sup 99m/Tc-labeled C. parvum and killed at 10 min, 1, 4, and 24 hr. After iv. administration, labeled organisms were distributed primarily to the liver, the lungs, and the blood (46% of injected dose), followed by the gastrointestinal tract, the spleen, and the kidneys (11%). Total recoverable radioactivity, which was defined as the percentage of injected dose that was recovered, ranged from 59% at 10 min to 15% at 24 hr. Inmore » contrast to this, /sup 99m/TcS colloid, an inert particulate material, was localized almost entirely in the liver, and the amount recoverable remained constant over 24 hr. One hr after i.p. administration of /sup 99m/Tc-labeled C. parvum, the gastrointestinal tract accounted for 27% of the injected radioactivity, followed by liver, blood, and spleen (12%). This was rapidly excreted between 4 and 24 hr, at which time only 12% of the injected dose was recovered. The skin accounted for 54.6% of the injected radioactivity 1 hr after s.c. injection, 6% 4 hr after s.c. injection, and 0.8% at 24 hr after s.c. injection.« less

  1. Detecting protein losing enteropathy by Tc-99m dextran scintigraphy: a novel experience.

    PubMed

    Kapoor, Seema; Ratan, Simmi K; Kashyap, Ravi; Mittal, S K; Rajeshwari, K; Rawat, H; Verma, Jyoti

    2002-09-01

    To evaluate protien using enteropathy by Tc-99m dextran scintigraphy. Methods for detecting protein loss from the intestine revolve around fecal nitrogen excretion, the clearance of alpha-1 antitrypsin in stools and by endoscopic biopsy. The diagnosis of protein-losing enteropathy (PLE) can also be established by a scintigraphic method that is noninvasive, simple and requires no patient preparation or motivation. This diagnostic modality can also delineate the site of protein loss, thereby offering a targeted approach, and if need be, surgery. Radiolabelling of a non-protein, noncolloidal, nonparticulate and biofriendly molecule like dextran with Technetium-99m for imaging enteric protein loss was utilized in imaging eight children with PLE. The results were encouraging. The authors advocate the use of this diagnostic tool in identifying patients with PLE, particularly in the pediatric age group.

  2. Association of hyperfunctioning thyroid adenoma with thyroid cancer presenting as "trapping only" nodule at 99mTcO4- scintigraphy.

    PubMed

    dell'Erba, L; Gerundini, P; Caputo, M; Bagnasco, M

    2003-11-01

    Rarely may a non-hyperfunctioning thyroid nodule present as "hot" at Technetium-99m pertechnetate (99mTcO4-) and "cold" at radioiodine scintigraphy at late acquisitions. We report the case of a hyperthyroid female patient whose 99mTcO4- scintigraphy showed two "hot" nodules, whereas Iodide-131 (131I-) revealed a lack of indicator uptake by the larger, and intense uptake by the smaller nodule. The patient underwent surgery: histology demonstrated that the larger nodule, mismatched at pertechnetate vs iodine scintigraphy, was a papillary carcinoma. Our suggestion is to perform thyroid scintigraphy with radioiodine in hyperthyroid patients with more than one nodule concentrating pertechnetate, especially when an ultrasonographic pattern possibly suspect for malignancy is present.

  3. Initial Evaluation of (99m)Tc(CO)3(ASMA) as a Renal Tracer in Healthy Human Volunteers.

    PubMed

    Lipowska, Malgorzata; Klenc, Jeffrey; Folks, Russell D; Taylor, Andrew T

    2014-09-01

    Preclinical studies in rats showed that two of (99m)Tc(CO)3(ASMA) isomers (rac- and L-ASMA) had pharmacokinetic properties equivalent to that of (131)I-OIH, the radiopharmaceutical standard for the measurement of effective renal plasma flow. The aim of this study was to evaluate the pharmacokinetics of (99m)Tc(CO)3(ASMA) isomers in healthy human subjects. Three ASMA ligands (rac-, L- and D-ASMA) were labeled with (99m)Tc(CO)3 using an IsoLink kit (Covidien), and each formed (99m)Tc(CO)3(ASMA) tracer was co-injected with (131)I-OIH into healthy human subjects followed by sequential imaging, plasma clearance measurements and timed urine collection. Plasma protein binding, red cell uptake and percent injected dose in the urine were determined. Urine from each group of volunteers was analyzed for metabolites by HPLC. Image quality was excellent with all three agents. Each (99m)Tc(CO)3(ASMA) preparation was excreted unchanged in the urine. The plasma clearance ratio ((99m)Tc(CO)3(ASMA)/(131)I-OIH) was 81 ± 3 % for D-ASMA compared to only 20 ± 4 % for L-ASMA and 37 ± 7 % for rac-ASMA; the 81 % clearance ratio for D-ASMA isomer is still ∼ 30 % higher than the (99m)Tc-MAG3/(131)I-OIH clearance ratio (∼50-60 %). Red cell uptake was similar for all three tracers (6-9 %), and all tracers had a relatively rapid renal excretion; at 3 h, the (99m)Tc(CO)3(ASMA)/(131)I-OIH urine ratio was 100 ± 3 % for D-ASMA, 80 ± 2 % for L-ASMA and 88 ± 1 % for rac-ASMA. The renal excretion characteristics of (99m)Tc(CO)3(D-ASMA) in humans are superior to those of the other two (99m)Tc(CO)3(ASMA) isomers studied, but are still inferior to (131)I-OIH, even though there was no difference in the clearance of two of (99m)Tc(CO)3(ASMA) isomers and (131)I-OIH in rats. The work described here demonstrates the sensitivity in in vivo biological behavior of (99m)Tc(CO)3(ASMA) isomers to their subtle structural differences.

  4. Sentinel Lymphadenectomy in Vulvar Cancer Using Near-Infrared Fluorescence From Indocyanine Green Compared With Technetium 99m Nanocolloid.

    PubMed

    Soergel, Philipp; Hertel, Hermann; Nacke, Anna Kaarina; Klapdor, Rüdiger; Derlin, Thorsten; Hillemanns, Peter

    2017-05-01

    Nowadays, sentinel diagnostic is performed using technetium 99m (Tc) nanocolloid as a radioactive marker and sometimes patent blue. In the last years, indocyanine green has been evaluated for sentinel diagnostic in different tumor entities. Indocyanine green is a fluorescent molecule that emits a light signal in the near-infrared band after excitation. Our study aimed to evaluate indocyanine green compared with the criterion-standard Tc-nanocolloid. We included patients with primary, unifocal vulvar cancer of less than 4 cm with clinically node-negative groins in this prospective trial. Sentinel diagnostic was carried out using Tc-nanocolloid, indocyanine green, and patent blue. We examined each groin for light signals from the near-infrared band, for radioactivity, and for blue staining. A sentinel lymph node was defined as a Tc-nanocolloid-positive lymph node. All sentinel lymph nodes and all additional blue or fluorescent lymph nodes were excised and tested and then sent for histologic examination. In all, 27 patients were included in whom we found 91 sentinel lymph nodes in 52 groins. All these lymph nodes were positive for indocyanine green, also giving a sensitivity of 100% (95% confidence interval [CI], 96.0%-100%) compared with Tc-nanocolloid. Eight additional lymph nodes showed indocyanine green fluorescence but no Tc positivity, so that the positive predictive value was 91.9% (95% confidence interval, 84.6%-96.5%). In 1 patient, a false-negative sentinel missed by all 3 modalities was found. Our results show that indocyanine green is a promising approach for inguinal sentinel identification in vulvar cancer with a similar sensitivity as radioactive Tc-nanocolloid and worth to be evaluated in further studies.

  5. A rare case of suprahepatic gall bladder with phocomelia and pancytopenia: detected by tc-99m mebrofenin scintigraphy.

    PubMed

    Rather, Tanveeer Ah; Khan, Shoukat H; Singh, Manjeet; Choh, Naseer A

    2013-01-01

    The possibility of an ectopic gallbladder should always be considered whenever there is a failure to localize it in its normal anatomical position on routine imaging. Although a very rare entity, the anomalous position of gallbladder can result in misinterpretation of imaging findings and create clinical confusion. Awareness of such an anomaly facilitates proper diagnosis and subsequent management. The authors report a very rare case of suprahepatic gallbladder associated with phocomelia, pancytopenia, and splenomegaly in a young 25-year-old female. The suprahepatic gallbladder was initially visualized on Technetium-99m (Tc-99m) Mebrofenin radionuclide hepatobiliary scintigraphy. Subsequent magnetic resonance cholecystopancreatography (MRCP) was also done to confirm the diagnosis.

  6. Detection of occult pericardial hemorrhage early after open-heart surgery using technetium-99m red blood cell radionuclide ventriculography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bateman, T.M.; Czer, L.S.; Gray, R.J.

    1984-11-01

    Pericardial or mediastinal hemorrhage requiring reoperation occurs in 2% to 5% of patients, usually early (0 to 48 hours), after open-heart surgery. This hemorrhage may be occult, and resulting cardiac tamponade may easily be misinterpreted as ventricular dysfunction, common early postoperatively. In such cases, appropriate and timely intervention may not occur. Of 50 patients evaluated by technetium-99m red blood cell gated equilibrium radionuclide ventriculography (RNV) because of early postoperative cardiogenic shock of uncertain etiology, 17 had unique scintigraphic images suggestive of intrathoracic hemorrhage. Of these 17, 5 had a generalized halo of abnormal radioactivity surrounding small hyperdynamic right and leftmore » ventricles, 11 had localized regions of intense blood pool activity outside the cardiac chambers (two with compression of single chambers), and one demonstrated marked radionuclide activity in the right hemithorax (2000 ml of blood at reoperation). Twelve patients had exploratory reoperation for control of hemorrhage as a direct result of the scintigraphic findings, three were successfully treated with fresh frozen plasma and platelet infusions along with medical interventions to optimize cardiac performance, and two patients died in cardiogenic shock (presumed tamponade) without reoperation. In the 12 reoperated patients, all were confirmed to have active pericardial bleeding. Scintigraphic localization of abnormal blood pools within the pericardium corresponded to the sites at which active bleeding was witnessed at reoperation. The abnormal bleeding was etiologically related to the tamponade state, with marked improvement in hemodynamics after reoperation. Nine additional patients were reoperated for presumed tamponade after RNV revealed an exaggerated halo of photon deficiency surrounding the cardiac chambers.« less

  7. Synthesis and biological evaluation of (99m)Tc-DMP-NGA as a novel hepatic asialoglycoprotein receptor imaging agent.

    PubMed

    Yang, Wenjiang; Mou, Tiantian; Zhang, Xianzhong; Wang, Xuebin

    2010-01-01

    A novel bifunctional coupling agents-biomolecular compound DMP-NGA was prepared by coupling the SATP with galactosyl-neoglycoalbumin (NGA). The DMP-NGA was labeled with technetium-99m, and the radiochemical purity in excess of 98% after purified with HPLC. In vivo biodistribution showed that (99m)Tc-DMP-NGA had very high initial liver uptake with good retention. The liver accumulated 99.35+/-9.77%, 74.25+/-3.03%, 52.47+/-7.58% of the injected dose per gram at 5, 30 and 120min after injection, respectively. It had relative higher initial liver uptake and much lower blood uptake than that of (99m)Tc-GSA. The liver/blood ratio reached 83.4 at 30min post-injection, while the ratio of liver/kidney was 14.4. The uptakes in other organs in the abdomen were also slightly low. In addition, the hepatic uptake of (99m)Tc-DMP-NGA was blocked by preinjecting free GSA as blocking agent. The result indicates that (99m)Tc-DMP-NGA has specific binding to ASGP receptor. Images acquired with Kodak In-Vivo Imaging System FX Pro showed significant difference before and after inhibition. The promising biological properties of (99m)Tc-DMP-NGA afford potential applications in liver receptor imaging for assessment of hepatocyte function.

  8. Identification of Staphylococcus aureus infection by aptamers directly radiolabeled with technetium-99m.

    PubMed

    dos Santos, Sara Roberta; Rodrigues Corrêa, Cristiane; Branco de Barros, André Luís; Serakides, Rogéria; Fernandes, Simone Odília; Cardoso, Valbert Nascimento; de Andrade, Antero Silva Ribeiro

    2015-03-01

    Aptamers are oligonucleotides that have high affinity and specificity for their molecular targets which are emerging as a new class of molecules for radiopharmaceuticals development. In this study, aptamers selected to Staphylococcus aureus were evaluated for bacterial infection identification. Anti S. aureus aptamers were labeled with (99m)Tc by the direct method. The radiolabel yield and complex stability were assessed by thin-layer chromatography (TLC). Three groups of Swiss mice containing 6 animals each were used. The first group was infected intramuscularly in the right thigh with S. aureus. The second group was infected in the same way with C. albicans and the third group was injected with zymosan to induce aseptic inflammation. After 24 h, radiolabeled aptamers (22.2 MBq) were injected by the tail vein. The mice were euthanized 4 h post injection and tissue sample activities measured in a gamma counter. The (99m)Tc labeled aptamers were stable in saline, plasma and cystein excess. Radiolabeled aptamers showed increased uptake in the kidneys for all groups indicating a main renal excretion, which is consistent with the hydrophilic nature and small size of aptamers. The radiopharmaceutical showed rapid blood clearance indicated by a reduced dose (% ID/g) in the blood. The biodistribution showed that aptamers were able to identify the infection foci caused by S. aureus displaying a target/non-target ratio of 4.0±0.5. This ratio for mice infected with C. albicans was 2.0±0.4 while for mice with aseptic inflammation was 1.2±0.2. Histology confirmed the presence of infection in groups 1 and 2, and inflammation in group 3. The biodistibution study demonstrated a statistically higher uptake in the S. aureus foci relative to inflammation and C. albicans infected areas. These results highlight the potential of aptamers labeled directly with (99m)Tc for bacterial infection diagnosis by scintigraphy. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Technetium-99m and rhenium-188 complexes with one and two pendant bisphosphonate groups for imaging arterial calcification.

    PubMed

    Bordoloi, Jayanta Kumar; Berry, David; Khan, Irfan Ullah; Sunassee, Kavitha; de Rosales, Rafael Torres Martin; Shanahan, Catherine; Blower, Philip J

    2015-03-21

    The first (99m)Tc and (188)Re complexes containing two pendant bisphosphonate groups have been synthesised, based on the mononuclear M(v) nitride core with two dithiocarbamate ligands each with a pendant bisphosphonate. The structural identity of the (99)Tc and stable rhenium analogues as uncharged, mononuclear nitridobis(dithiocarbamate) complexes was determined by electrospray mass spectrometry. The (99m)Tc complex showed greater affinity for synthetic and biological hydroxyapatite, and greater stability in biological media, than the well-known but poorly-characterised and inhomogeneous bone imaging agent (99m)Tc-MDP. It gave excellent SPECT images of both bone calcification (mice and rats) and vascular calcification (rat model), but the improved stability and the availability of two pendant bisphosphonate groups conferred no dramatic advantage in imaging over the conventional (99m)Tc-MDP agent in which the bisphosphonate group is bound directly to Tc. The (188)Re complex also showed preferential uptake in bone. These tracers and the biological model of vascular calcification offer the opportunity to study the biological interpretation and clinical potential of radionuclide imaging of vascular calcification and to deliver radionuclide therapy to bone metastases.

  10. An estimate of the inventory of technetium-99 in the sub-tidal sediments of the Irish Sea.

    PubMed

    Jenkinson, Stuart B; McCubbin, David; Kennedy, Paul H W; Dewar, Alastair; Bonfield, Rachel; Leonard, Kinson S

    2014-07-01

    Published results from earlier studies have provided indications that measurable quantities of technetium-99 ((99)Tc) have accumulated in the sub-tidal sediments of the Irish Sea. This is due to the enhanced discharges from the Sellafield nuclear reprocessing plant in Cumbria, UK (between 1994 and 2004). Depth distributions of (99)Tc concentrations in sub-tidal sediments have been determined from a limited number of Irish Sea sites, following the collection of deep sediment cores (up to 2 m in depth), sampled in two research cruise surveys in 2005 and 2006. Vertical concentration profiles of (99)Tc from a range of substrates in the Irish Sea are presented here and these have been used to produce an estimate of the total inventory of (99)Tc residing in the sub-tidal sediments of the Irish Sea. Significant variation was observed between (99)Tc concentrations in the sediment samples, as well as in the shape of individual depth profiles. As anticipated, concentrations tended to be greater on fine-grained (muddy) substrates and showed a general decrease with distance from Sellafield. Vertical concentration profiles of (137)Cs, and (137)Cs data from published work, have also been considered to evaluate the use of the relatively few (99)Tc core data (upon which to determine the (99)Tc inventory). The inventories of (99)Tc and (137)Cs are estimated to have been of the order of 30 and 455 terabecquerels (TBq), respectively, or ∼2% of the total cumulative Sellafield discharge for each of the two radionuclides. The residence half-time of (137)Cs in the sub-tidal sediments of the Irish Sea is estimated to be in the order of ∼16 years. Therefore, as the Kd values for (99)Tc and (137)Cs are similar, this also provides an indicative value to predict future losses of (99)Tc from the sediment reservoir. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  11. Bone marrow uptake of 99mTc-MIBI in patients with multiple myeloma.

    PubMed

    Fonti, R; Del Vecchio, S; Zannetti, A; De Renzo, A; Di Gennaro, F; Catalano, L; Califano, C; Pace, L; Rotoli, B; Salvatore, M

    2001-02-01

    In a previous study, we showed the ability of technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) scan to identify active disease in patients with multiple myeloma (Eur J Nucl Med 1998; 25: 714-720). In particular, a semiquantitative score of the extension and intensity of bone marrow uptake was derived and correlated with both the clinical status of the disease and plasma cell bone marrow infiltration. In order to estimate quantitatively 99mTc-MIBI bone marrow uptake and to verify the intracellular localization of the tracer, bone marrow samples obtained from 24 multiple myeloma patients, three patients with monoclonal gammopathy of undetermined significance (MGUS) and two healthy donors were studied for in vitro uptake. After centrifugation over Ficoll-Hypaque gradient, cell suspensions were incubated with 99mTc-MIBI and the uptake was expressed as the percentage of radioactivity specifically retained within the cells. The cellular localization of the tracer was assessed by micro-autoradiography. Twenty-two out of 27 patients underwent 99mTc-MIBI scan within a week of bone marrow sampling. Whole-body images were obtained 10 min after intravenous injection of 555 MBq of the tracer; the extension and intensity of 99mTc-MIBI uptake were graded using the semiquantitative score. A statistically significant correlation was found between in vitro uptake of 99mTc-MIBI and both plasma cell infiltration (Pearson's coefficient of correlation r=0.69, P<0.0001) and in vivo score (Spearman rank correlation coefficient r=0.60, P<0.01). No specific tracer uptake was found in bone marrow samples obtained from the two healthy donors. Micro-autoradiography showed localization of 99mTc-MIBI inside the plasma cells infiltrating the bone marrow. Therefore, our findings show that the degree of tracer uptake both in vitro and in vivo is related to the percentage of infiltrating plasma cells which accumulate the tracer in their inner compartments.

  12. Studies on focal alveolar bone healing with technetium (Tc)-99m labeled methylene diphosphonate and gold-collimated cadmium telluride probe

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tsuchimochi, M.; Hosain, F.; Engelke, W.

    1991-01-01

    The benefit of using a collimator for a miniaturized cadmium telluride probe was evaluated by monitoring the bone-healing processes for 13 weeks after the induction of small iatrogenic alveolar bone lesions in one side of the mandible in beagles. Technetium (Tc)-99m labeled methylene diphosphonate (200 to 300 MBq, 5.1 to 8.1 mCi, in a solution of 0.5 to 1 ml, intravenously) was used as a bone-seeking radiopharmaceutical. The radioactivity over the bone lesion (L) and the contralateral normal site (C) in the mandible were measured between 1.5 and 2 hours after injection of the tracer, and the activity ratio L/Cmore » served as an index of relative bone uptake. A study of six dogs revealed that the healing response to a hemispheric bone defect of 2 mm diameter in the cortical bone could not be detected by an uncollimated probe, and in a repeated study in two dogs the use of a gold collimator (5 mm in diameter, 5 mm in length) did not increase the L/C ratio significantly. A second study in six dogs with 5 mm lesions showed that although systematic trends in the time courses of the L/C ratio obtained both with and without the collimator could be demonstrated, the L/C ratio of collimated versus uncollimated measurements was significantly (p less than 0.005) increased. In three of the latter six dogs, abscesses developed after 9 weeks, leading to a second increase (p less than 0.05) of the L/C ratio with collimation compared with the noninflammation group; without collimation no significant (p greater than 0.15) difference between the two groups could be demonstrated.« less

  13. A Rare Case of Suprahepatic Gall Bladder with Phocomelia and Pancytopenia: Detected by Tc-99m Mebrofenin Scintigraphy

    PubMed Central

    Rather, Tanveeer Ah; Khan, Shoukat H.; Singh, Manjeet; Choh, Naseer A.

    2013-01-01

    The possibility of an ectopic gallbladder should always be considered whenever there is a failure to localize it in its normal anatomical position on routine imaging. Although a very rare entity, the anomalous position of gallbladder can result in misinterpretation of imaging findings and create clinical confusion. Awareness of such an anomaly facilitates proper diagnosis and subsequent management. The authors report a very rare case of suprahepatic gallbladder associated with phocomelia, pancytopenia, and splenomegaly in a young 25-year-old female. The suprahepatic gallbladder was initially visualized on Technetium-99m (Tc-99m) Mebrofenin radionuclide hepatobiliary scintigraphy. Subsequent magnetic resonance cholecystopancreatography (MRCP) was also done to confirm the diagnosis. PMID:23961256

  14. Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates.

    PubMed

    Hou, X; Tanguay, J; Buckley, K; Schaffer, P; Bénard, F; Ruth, T J; Celler, A

    2016-01-21

    In response to the recognized fragility of reactor-produced (99)Mo supply, direct production of (99m)Tc via (100)Mo(p,2n)(99m)Tc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with (99m)Tc, other technetium (Tc) radioactive isotopes (impurities) will be produced. They will be incorporated into the labeled radiopharmaceuticals and result in increased patient dose. The isotopic composition of the target and beam energy are main factors that determine production of impurities, thus also dose increases. Therefore, they both must be considered when selecting targets for clinical (99m)Tc production. Although for any given Mo target, the patient dose can be predicted based on complicated calculations of production yields for each Tc radioisotope, it would be very difficult to reverse these calculations to specify target composition based on dosimetry considerations. In this article, a relationship between patient dosimetry and Mo target composition is studied. A simple and easy algorithm for dose estimation, based solely on the knowledge of target composition and beam energy, is described. Using this algorithm, the patient dose increase due to every Mo isotope that could be present in the target is estimated. Most importantly, a technique to determine Mo target composition thresholds that would meet any given dosimetry requirement is proposed.

  15. Molybdenum target specifications for cyclotron production of 99mTc based on patient dose estimates

    NASA Astrophysics Data System (ADS)

    Hou, X.; Tanguay, J.; Buckley, K.; Schaffer, P.; Bénard, F.; Ruth, T. J.; Celler, A.

    2016-01-01

    In response to the recognized fragility of reactor-produced 99Mo supply, direct production of 99mTc via 100Mo(p,2n)99mTc reaction using medical cyclotrons has been investigated. However, due to the existence of other Molybdenum (Mo) isotopes in the target, in parallel with 99mTc, other technetium (Tc) radioactive isotopes (impurities) will be produced. They will be incorporated into the labeled radiopharmaceuticals and result in increased patient dose. The isotopic composition of the target and beam energy are main factors that determine production of impurities, thus also dose increases. Therefore, they both must be considered when selecting targets for clinical 99mTc production. Although for any given Mo target, the patient dose can be predicted based on complicated calculations of production yields for each Tc radioisotope, it would be very difficult to reverse these calculations to specify target composition based on dosimetry considerations. In this article, a relationship between patient dosimetry and Mo target composition is studied. A simple and easy algorithm for dose estimation, based solely on the knowledge of target composition and beam energy, is described. Using this algorithm, the patient dose increase due to every Mo isotope that could be present in the target is estimated. Most importantly, a technique to determine Mo target composition thresholds that would meet any given dosimetry requirement is proposed.

  16. Technetium-99 conjugated with methylene diphosphonate ameliorates ovariectomy-induced osteoporotic phenotype without causing osteonecrosis in the jaw.

    PubMed

    Zhao, Yinghua; Wang, Lei; Liu, Yi; Akiyama, Kentaro; Chen, Chider; Atsuta, Ikiru; Zhou, Tao; Duan, Xiaohong; Jin, Yan; Shi, Songtao

    2012-12-01

    Technetium-99 conjugated with methylene diphosphonate ((99)Tc-MDP) is a novel bisphosphonate derivative without radioactivity and has been successfully used to treat arthritis in China for years. Since bisphosphonate therapy has the potential to induce bisphosphonate-related osteonecrosis of the jaw (BRONJ), we examined whether (99)Tc-MDP represents a new class of bisphosphonate for antiresorptive therapy to ameliorate estrogen deficiency-induced bone resorption with less risk of causing BRONJ. We showed that (99)Tc-MDP-treated, ovariectomized (OVX) mice had significantly improved bone mineral density and trabecular bone volume in comparison to the untreated OVX group by inhibiting osteoclasts and enhancing osteogenic differentiation of bone marrow mesenchymal stem cells. To determine the potential of inducing BRONJ, (99)Tc-MDP/dexamethasone (Dex) or zoledronate/Dex was administered into C57BL/6J mice via the tail vein, followed by extraction of maxillary first molars. Interestingly, (99)Tc-MDP treatment showed less risk to induce osteonecrosis in the maxillary bones compared to zoledronate treatment group, partially because (99)Tc-MDP neither suppressed adaptive regulatory T cells nor activated the inflammatory T-helper-producing interleukin-17 cells. Taken together, our findings demonstrate that (99)Tc-MDP therapy may be a promising approach in the treatment of osteoporosis with less risk of causing BRONJ.

  17. Water-stable fac-{TcO₃}⁺ complexes - a new field of technetium chemistry.

    PubMed

    Braband, Henrik

    2011-01-01

    The development of technetium chemistry has been lagging behind that of its heavier congener rhenium, primarily because the inherent radioactivity of all Tc isotopes has limited the number of laboratories that can study the chemistry of this fascinating element. Although technetium is an artificial element, it is not rare. Significant amounts of the isotope (99)Tc are produced every day as a fission byproduct in nuclear power plants. Therefore, a fundamental understanding of the chemistry of (99)Tc is essential to avoid its release into the environment. In this article the chemistry of technetium at its highest oxidation state (+VII) is reviewed with a special focus on recent developments which make water-stable complexes of the general type [TcO(3)(tacn-R)](+) (tacn-R = 1,4,7-triazacyclononane or derivatives) accessible. Complexes containing the fac-{TcO(3)}(+) core display a unique reactivity. In analogy to [OsO(4)] and [RuO(4)], complexes containing the fac-{TcO(3)}(+) core undergo with alkenes metal-mediated, vicinal cis-dihydroxylation reactions (alkene-glycol interconversion) in water via a (3+2)-cycloaddition reaction. Therefore, water-stable fac-{(99m)TcO(3)}(+) complexes pave the way for a new labeling strategy for radiopharmaceutical applications, based on (3+2)-cycloaddition reactions. This new concept for the labeling of biomolecules with small [(99m)TcO(3)(tacn-R)](+)-type complexes by way of a (3+2)-cycloaddition with alkenes is discussed in detail. The herein reported developments in high-valent technetium chemistry create a new field of research with this artificial element. This demonstrates the potential of fundamental research to provide new impetus of innovation for the development of new methods for radiopharmaceutical applications.

  18. Comparison of personnel radiation dosimetry from myocardial perfusion scintigraphy: Technetium-99m-sestamibi versus thallium-201

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Culver, C.M.; Dworkin, H.J.

    1993-07-01

    The whole-body and hand radiation doses to our technical staff were retrospectively compared for three distinct 4-mo periods when either 201TI or 99mTc-sestamibi were exclusively used for stress myocardial perfusion imaging. During the initial 4-mo period when 99mTc-sestamibi replaced 201TI, the mean whole-body film badge readings increased from 100 to 450 microSv/mo (p < 0.001) for nuclear medicine technologists (n = 10) and from 240 to 560 microSv/mo (p < 0.05) for radiopharmacy technologists (n = 2). Mean TLD readings to the hands also increased, although the differences were not statistically significant for the nuclear medicine technologists. Noninvasive cardiology staffmore » were monitored with film badges and the mean whole-body film badge reading, when 99mTc-sestamibi was the imaging agent, was 360 microSv per month. Radiation reduction methods that decreased radiation exposure to staff were utilized. The most effective included the use of a lead face shield and lead lined storage container in the noninvasive imaging area, handling spills by shielding instead of decontamination and methods to reduce time spent in close proximity to the patient.« less

  19. Diagnosis of pyogenic pelvic inflammatory diseases by 99mTc-HMPAO leucocyte scintigraphy.

    PubMed

    Rachinsky, I; Boguslavsky, L; Goldstein, D; Golan, H; Pak, I; Katz, M; Lantsberg, S

    2000-12-01

    Pelvic inflammatory disease (PID) is one of the major health problems of women of child-bearing age. Among the most serious complications of PID is the formation of a tubo-ovarian abscess (TOA). Early diagnosis of this condition may prevent serious surgical complications such as peritonitis and sepsis, which may be fatal. The purpose of this study was to investigate the efficacy of technetium-99m hexamethylpropylene amine oxime (HMPAO) leucocyte scintigraphy in the diagnosis of TOA. Twenty women with high clinical suspicion of TOA underwent 99mTc-HMPAO leucocyte scintigraphy. The labelling of leucocytes with 99mTc-HMPAO was performed according to a standard protocol. Scans were obtained at 1, 3 and 24 h following the injection of the labelled leucocytes. In eight cases the early and/or late scan was positive, in 11 cases it was negative, and in one case of ovarian cyst torsion, confirmed by laparoscopy, it showed slight uptake in the capsule of the cyst (false-positive). The sensitivity of 99mTc-HMPAO leucocyte scintigraphy was 100%, specificity 91.6%, positive predictive value 89%, negative predictive value 100% and overall accuracy 95%. It is concluded that leucocyte scintigraphy is a non-invasive, safe, physiological and accurate procedure for the diagnosis of TOA. The 24-h scan is crucial, since in some cases the abscess was not clearly visualized on the early scan. Leucocyte scintigraphy may reduce the need for CT, diagnostic laparoscopy and unnecessary invasive surgical procedures.

  20. An efficient HPLC method for the analysis of isomeric purity of technetium-99m-exametazime and identity confirmation using LC-MS.

    PubMed

    Vanderghinste, D; Van Eeckhoudt, M; Terwinghe, C; Mortelmans, L; Bormans, G M; Verbruggen, A M; Vanbilloen, H P

    2003-08-08

    99mTc-exametazime (99mTc-d,l-HMPAO, 99mTc-d,l-hexamethylpropyleneamine oxime) is a neutral rather unstable complex of short-lived 99mTc (t(1/2)=6 h) with the d,l-isomer (mixture of D,D- and L,L-isomers) of a bis-amine bis-oxime tetraligand. It is widely used for measurement of regional cerebral perfusion in nuclear medicine. The meso-isomer (D,L-form) should not be present in a preparation as it is not retained in brain and thus does not provide clinically useful information. Meso-HMPAO is removed from the ligand during the synthesis procedure by repeated recrystallization, but can still be present as impurity in d,l-isomer. Due to the lack of a suitable chromatographic method for analysis of the isomeric purity of 99mTc-exametazime preparations, United States Pharmacopoeia 25 (USP 25) prescribes a biological test in rats for quality control purpose. In this study, we developed a suitable high-performance liquid chromatography (HPLC) method which allows to demonstrate the relative amounts of d,l- and meso-isomer in 99mTc-exametazime and so obviates the need for a biodistribution test in animals as part of the quality control. Due to the low concentrations in which 99mTc-d,l-HMPAO is obtained (typically 2-6 ng/ml), confirmation of the identity of 99mTc-d,l-HMPAO in the monograph of the European Pharmacopoeia is now performed only indirectly by TLC and assessment of its retention time on RP-HPLC. To investigate the potential of radio-LC-MS for assessment of the identity of 99mTc-exametazime, 99mTc-d,l-HMPAO and 99mTc-meso-HMPAO prepared using a Tc-rich eluate were analyzed using a radio-LC-MS system equipped with a time-of-flight mass spectrometer with electrospray ionization. The main peak in the radiometric channel coincided with the molecular ion mass of 99mTc-d,l-HMPAO in the mass spectrometer channel and the measured accurate mass differed only by 0.26 ppm from the theoretical mass. The identity of 99mTc-meso-HMPAO was also confirmed. Thus, radio-LC-MS allowed

  1. Poor accumulation of technetium-99m glucoheptonate in sarcoidosis and other diffuse infiltrative lung diseases as compared with gallium-67 citrate

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vorne, M.; Sahlstroem, K.A.; Alanko, K.

    1988-02-01

    Forty-two patients with diffuse infiltrative lung diseases were imaged with Ga-67 citrate and Tc-99m glucoheptonate (GH). Twenty patients had sarcoidosis, six had fibrosis, six had tuberculosis, nine had lung infiltration, and one had pleural empyema. The main difference between Ga-67 and Tc-99m GH was the much greater uptake of Ga-67 in sarcoidosis than that of Tc-99m GH. Fifteen patients with sarcoidosis had positive Ga-67 scans but only six had positive Tc-99m GH scans. The results in other diffuse infiltrative lung diseases were almost equal with Ga-67 and Tc-99m GH. Although Tc-99m GH is less expensive and simpler to use, itmore » is not an adequate substitute for Ga-67 in diffuse infiltrative lung diseases.« less

  2. A novel approach to infection imaging using a synthetic Tc-99m-labeled leukotactic peptide

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Som, P.; Oster, Z.H.; Sharma, S.

    1996-05-01

    RMT1, a synthetic peptide binding to PMN and macrophage receptors was labeled with Tc-99m and investigated as a potential imaging agent for abscess and inflammation. Experimental abscesses were induced in rabbits and dogs by turpentine and E.coli injection. After injection of Tc-99m-RMT1 two and twelve day old abscesses were visualized within 20 min. In initial studies, a dose of 30 {mu}g of peptide/3 mCi was used. This amount was subsequently reduced to 1.5 {mu}g peptide with same amount of Tc-99m yielding similar imaging results. Technetium-99m-IgG and Tc-99m-MAG-3 were used as positive and negative controls, respectively. After injection of IgG abscessesmore » were visualized but activity in blood was always higher than in abscess. When using Tc-99m RMT1 rapid abscess visualization and faster blood clearance was observed. The accumulation of RMT1 was monophasic, i.e., following the initial visualization, activity continued to build up continuously for 1{1/2} hr. Tc-99m-MAG3 accumulated initially in abscess, but activity washed out. In dogs, RMT1 blood clearance showed three components: a fast component with t{1/2}=1.9 min, 73%, intermediate t{1/2}=22 min, 24.5% and slow component, t{1/2}=115, 9.5% with 3 hours cumulative urine excretion of 40-51%. RMT1 appears to be more advantageous than currently available methods because of rapidity of imaging, simpler preparation before injection and will probably be less expensive and time consuming compared to labeled WBC. These results indicate that clinical experiments are warranted.« less

  3. A freeze-dried kit formulation for the preparation of Lys(27)(99mTc-EDDA/HYNIC)-Exendin(9-39)/99mTc-EDDA/HYNIC-Tyr3-Octreotide to detect benign and malignant insulinomas.

    PubMed

    Medina-García, Veronica; Ocampo-García, Blanca E; Ferro-Flores, Guillermina; Santos-Cuevas, Clara L; Aranda-Lara, Liliana; García-Becerra, Rocio; Ordaz-Rosado, David; Melendez-Alafort, Laura

    2015-12-01

    About 90% of insulinomas are benign and 5%-15% are malignant. Benign insulinomas express the glucagon-like peptide-1 receptor (GLP-1R) and low levels of somatostatin receptors (SSTR), while malignant insulinomas over-express SSTR or GLP-1R in low levels. A kit for the preparation of Lys(27)((99m)Tc-EDDA/HYNIC)-Exendin(9-39)/(99m)Tc-EDDA/HYNIC-Tyr(3)Octreotide was formulated to detect 100% of insulinomas. The formulation showed radiochemical purity of 97±1%, high stability in human serum, and GLP-1R and SSTR affinity. The biodistribution and imaging studies demonstrated properties suitable for its use as a target-specific agent for the simultaneous molecular imaging of GRP-1R- and/or SSTR-positive tumors. Copyright © 2015 Elsevier Inc. All rights reserved.

  4. Radiolabelling of glycosylated MFE-23::CPG2 fusion protein (MFECP1) with 99mTc for quantitation of tumour antibody-enzyme localisation in antibody-directed enzyme pro-drug therapy (ADEPT).

    PubMed

    Francis, R J; Mather, S J; Chester, K; Sharma, S K; Bhatia, J; Pedley, R B; Waibel, R; Green, A J; Begent, R H J

    2004-08-01

    MFECP1 is a glycosylated recombinant fusion protein composed of MFE-23, a high-affinity anti-carcinoembryonic antigen (CEA) single chain Fv (scFv), fused to the enzyme carboxypeptidase G2 (CPG2), and has been constructed for use in antibody-directed enzyme pro-drug therapy (ADEPT). Radiolabelling of glycosylated MFECP1 with technetium-99m was developed for the purpose of determining tumour localisation of MFECP1 in a phase I ADEPT clinical study. The method used was 99mTc-carbonyl [99mTc(H2O)3(CO)3]+ (abbreviated to TcCO) mediated labelling of 99mTc to the hexahistidine (His) tag of MFECP1. MFECP1 fusion protein was labelled with TcCO under a variety of conditions, and this was shown to be a relatively simple and robust method. Tissue biodistribution was assessed in a CEA-expressing LS174T (human colon carcinoma) nude mouse xenograft model. Tissues were taken at 1, 4 and 6 h for assessment of distribution of radioactivity and for measurement of CPG2 enzyme levels. The amount of radioactivity retained by the tumour proved to be an accurate estimation of actual measured enzyme activity, indicating that this radiolabelling method does not appear to damage the antibody-antigen binding or the enzyme activity of MFECP1. However, correlation between CPG2 enzyme activity and measured radioactivity in liver, spleen and kidney was poor, indicating retention of radioactivity in non-tumour sites but loss of enzyme activity. The high retention of technetium radioisotope in normal tissues may limit the clinical applicability of this radiolabelling method for MFECP1; however, these results suggest that this technique does have applicability for measuring the biodistribution of His-tagged recombinant proteins.

  5. Positioning irrigation of contrast cystography for diagnosis of occult vesicoureteric reflux: association with technetium-99m dimercaptosuccinic acid scans.

    PubMed

    Berger, Christoph; Becker, Tanja; Koen, Mark; Zeino, Mazen; Fitz, Friedrich; Beheshti, Mohsen; Wolf-Kohlmeier, Iris; Haim, Silke; Riccabona, Marcus

    2013-12-01

    Positioning irrigation of contrast (PIC) cystography identifies occult or PIC vesicoureteral reflux (PIC-VUR) in children with recurrent febrile urinary tract infections (UTI) but no vesicoureteric reflux (VUR) on standard voiding cystourethrogram (VCUG). We sought to identify the relationship between PIC-VUR and renal scarring in technetium-99m dimercaptosuccinic acid (DMSA) scans. We retrospectively analysed PIC cystograms and DMSA scans for 154 kidneys in 81 children (65 girls; 16 boys; median age, 4.7 years; range, 0.9-15.2). Renal scarring was graded on a scale of 0-3. DMSA scans were pathologic in 66 patients (81%). Children had experienced mean 3.8 febrile UTI (range 1-25). Forty-seven (58%) children had a history of reflux, including 15 (19%) with previous anti-reflux operations. Indications for PIC cystography were recurrence of febrile UTI after either bilateral negative VCUG (66 children) or unilateral VUR (15 children) with contralateral/bilateral scarring or reflux that had changed sides in subsequent VCUGs. PIC-VUR was bilateral in 63, unilateral in 12, and absent in 6 children. Statistically significant associations between PIC-VUR grade and severity of renal scarring were identified in inter-individual (n = 77, p = 0.017) and intra-individual (refluxing vs. nonrefluxing kidney; n = 12, p = 0.008) analyses. After excluding patients with history of VUR, statistical significance was maintained in inter-individual analysis (n = 49; p = 0.018). The data suggest an association between PIC-VUR and severity of renal scarring, and legitimise the use of PIC cystography in children with renal scarring due to recurrent febrile UTI but negative findings on VCUG. Copyright © 2012 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  6. Deep liquid-chromatographic purification of uranium extract from technetium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Volk, V.; Dvoeglazov, K; Podrezova, L.

    The recycling of uranium in the nuclear fuel cycle requires the removal of a number of radioactive and stable impurities like {sup 99}Tc from spent fuels. In order to improve the grade of uranium extract purification from technetium the method of liquid chromatography and the apparatus for its performance have been developed. Process of technetium extraction and concentrating in aqueous solution containing reducing agent has been studied on simulated solutions (U-Tc-HNO{sub 3}-30% TBP-isoparM). The dynamic tests of the method have been carried out on the laboratory unit. Solution of diformyl-hydrazine in nitric acid was used as a stationary phase. Silicamore » gel with specific surface of 186 m{sup 2}/g was used as a carrier of the stationary phase. It is shown that the volume of purified extract increases as the solution temperature increases, concentration of reducing agent increases and extract flow rate decreases. It is established that the technetium content in uranium by this method could achieve a value below 0.3 ppm. Some variants of overload and composition of the stationary phase containing the extracted technetium have been offered and tested. It is defined that the method provides reduction of processing medium-active wastes by more than 10 times during finish refining process. (authors)« less

  7. Early myocardial damage assessment in dystrophinopathies using (99)Tc(m)-MIBI gated myocardial perfusion imaging.

    PubMed

    Zhang, Li; Liu, Zhe; Hu, Ke-You; Tian, Qing-Bao; Wei, Ling-Ge; Zhao, Zhe; Shen, Hong-Rui; Hu, Jing

    2015-01-01

    Early detection of muscular dystrophy (MD)-associated cardiomyopathy is important because early medical treatment may slow cardiac remodeling and attenuate symptoms of cardiac dysfunction; however, no sensitive and standard diagnostic method for MD at an earlier stage has been well-recognized. Thus, the aim of this study was to test the early diagnostic value of technetium 99m-methoxyisobutylisonitrile ((99)Tc(m)-MIBI) gated myocardial perfusion imaging (G-MPI) for MD. Ninety-one patients underwent (99)Tc(m)-MIBI G-MPI examinations when they were diagnosed with Duchenne muscular dystrophy (DMD) (n=77) or Becker muscular dystrophy (BMD; n=14). (99)Tc(m)-MIBI G-MPI examinations were repeated in 43 DMD patients who received steroid treatments for 2 years as a follow-up examination. Myocardial defects were observed in nearly every segment of the left ventricular wall in both DMD and BMD patients compared with controls, especially in the inferior walls and the apices by using (99)Tc(m)-MIBI G-MPI. Cardiac wall movement impairment significantly correlated with age in the DMD and BMD groups (r s=0.534 [P<0.05] and r s=0.784 [P<0.05], respectively). Intermittent intravenous doses of glucocorticoids and continuation with oral steroid treatments significantly improved myocardial function in DMD patients (P<0.05), but not in BMD patients. (99)Tc(m)-MIBI G-MPI is a sensitive and safe approach for early evaluation of cardiomyopathy in patients with DMD or BMD, and can serve as a candidate method for the evaluation of progression, prognosis, and assessment of the effect of glucocorticoid treatment in these patients.

  8. Quantitation of left ventricular ejection fraction reserve from early gated regadenoson stress Tc-99m high efficiency SPECT

    PubMed Central

    Brodov, Yafim; Fish, Mathews; Rubeaux, Mathieu; Otaki, Yuka; Gransar, Heidi; Lemley, Mark; Gerlach, Jim; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2016-01-01

    Background Ejection fraction (EF) reserve has been found to be a useful adjunct for identifying high risk coronary artery disease in cardiac positron emission tomography (PET). We aimed to evaluate EF reserve obtained from technetium-99m sestamibi (Tc-99m) high-efficiency (HE) SPECT. Methods Fifty patients (mean age 69 y) undergoing regadenoson same-day rest (8–11 mCi)/stress (32–42mCi) Tc-99m gated HE SPECT were enrolled. Stress imaging was started one min after sequential intravenous regadenoson 0.4mg and Tc-99m injection, and was composed of five 2 min supine gated acquisitions followed by two 4 min supine and upright images. Ischemic total perfusion deficit (ITPD) ≥ 5 % was considered as significant ischemia. Results Significantly lower mean EF reserve was obtained in the 5th and 9th min after regadenoson bolus in patients with significant ischemia versus patients without (5th min: −4.2 ± 4.6% vs. 1.3 ± 6.6%, p = 0.006; 9th min: −2.7 ± 4.8% vs. 2.0 ± 6.6%, p = 0.03). Conclusions Negative EF reserve obtained between 5th and 9th min of regadenoson stress demonstrated best concordance with significant ischemia and may be a promising tool for detection of myocardial stunning with Tc-99m HE-SPECT. PMID:27387521

  9. Quantitation of left ventricular ejection fraction reserve from early gated regadenoson stress Tc-99m high-efficiency SPECT.

    PubMed

    Brodov, Yafim; Fish, Mathews; Rubeaux, Mathieu; Otaki, Yuka; Gransar, Heidi; Lemley, Mark; Gerlach, Jim; Berman, Daniel; Germano, Guido; Slomka, Piotr

    2016-12-01

    Ejection fraction (EF) reserve has been found to be a useful adjunct for identifying high risk coronary artery disease in cardiac positron emission tomography (PET). We aimed to evaluate EF reserve obtained from technetium-99m sestamibi (Tc-99m) high-efficiency (HE) SPECT. Fifty patients (mean age 69 years) undergoing regadenoson same-day rest (8-11 mCi)/stress (32-42 mCi) Tc-99m gated HE SPECT were enrolled. Stress imaging was started 1 minute after sequential intravenous regadenoson .4 mg and Tc-99m injections, and was composed of five 2 minutes supine gated acquisitions followed by two 4 minutes supine and upright images. Ischemic total perfusion deficit (ITPD) ≥5 % was considered as significant ischemia. Significantly lower mean EF reserve was obtained in the 5th and 9th minute after regadenoson bolus in patients with significant ischemia vs patients without (5th minute: -4.2 ± 4.6% vs 1.3 ± 6.6%, P = .006; 9th minute: -2.7 ± 4.8% vs 2.0 ± 6.6%, P = .03). Negative EF reserve obtained between 5th and 9th minutes of regadenoson stress demonstrated best concordance with significant ischemia and may be a promising tool for detection of transient ischemic functional changes with Tc-99m HE-SPECT.

  10. The distribution of 99mTc-EHDP in the tissues of the dog and its application in the assessment of fracture healing.

    PubMed

    Hughes, S

    1977-07-01

    Technetium-labelled ethane hydroxydiphosphonate (99mTc-EHDP) is a commonly used bone-scanning agent. After injection it leaves the circulation to enter bone and to be cleared by the kidney. The transcapillary exchange of 99mTc-EHDP in bone was examined and found to be low. The capillary movement was compared with that of sucrose, a freely diffusible substance, and it was found that the permeability ratio of 99mTc-EHDP to 14C-sucrose was similar to the diffusion coefficient ratio, suggesting that 99mTc-EHDP passes through the capillaries by the process of passive diffusion. The renal clearance of 99mTc-EHDP was 24 ml/min and was unaffected by the action of parathyroid hormone. After a fracture the bone blood flow increases, although the transcapillary extraction of 99mTc-EHDP does not change. This is because there is an increase, from recruitment and dilatation of capillaries, in the surface area available for exchange. Therefore the increased isotopic activity seen on a bone scan after a fracture is primarily related to an increase in bone blood supply from capillary enhancement within the cortex.

  11. Imaging discordance between hepatic angiography versus Tc-99m-MAA SPECT/CT: a case series, technical discussion and clinical implications.

    PubMed

    Kao, Yung Hsiang; Tan, Eik Hock; Teo, Terence Kiat Beng; Ng, Chee Eng; Goh, Soon Whatt

    2011-11-01

    During pre-therapy evaluation for yttrium-90 (Y-90) radioembolization, it is uncommon to find severe imaging discordance between hepatic angiography versus technetium-99m-macroaggregated albumin (Tc-99m-MAA) single photon emission computed tomography with integrated low-dose CT (SPECT/CT). The reasons for severe imaging discordance are unclear, and literature is scarce. We describe 3 patients with severe imaging discordance, whereby tumor angiographic contrast hypervascularity was markedly mismatched to the corresponding Tc-99m-MAA SPECT/CT, and its clinical impact. The incidence of severe imaging discordance at our institution was 4% (3 of 74 cases). We postulate that imaging discordance could be due to a combination of 3 factors: (1) different injection rates between soluble contrast molecules versus Tc-99m-MAA; (2) different arterial flow hemodynamics between soluble contrast molecules versus Tc-99m-MAA; (3) eccentric release position of Tc-99m-MAA due to microcatheter tip location, inadvertently selecting non-target microparticle trajectories. Tc-99m-MAA SPECT/CT more accurately represents hepatic microparticle biodistribution than soluble contrast hepatic angiography and should be a key criterion in patient selection for Y-90 radioembolization. Tc-99m-MAA SPECT/CT provides more information than planar scintigraphy to guide radiation planning and clinical decision making. Severe imaging discordance at pre-therapy evaluation is ominous and should be followed up by changes to the final vascular approach during Y-90 radioembolization.

  12. Streptozotocin (STZ) and schistosomiasis mansoni change the biodistribution of radiopharmaceutical sodium (99m)Tc-pertechnetate in mice.

    PubMed

    Góes, Vanessa Coelho; Neves, Renata Heisler; Arnóbio, Adriano; Bernardo-Filho, Mario; Machado-Silva, José Roberto

    2016-09-01

    Technetium-99m ((99m)Tc) is a radionuclide commonly used in nuclear medicine to obtain (99m)Tc-radiopharmaceuticals, which can be used to evaluate either physiological processes or changes related to diseases. It is also used in some experimental studies. Streptozotocin (STZ) administration to rodents causes lesions in very early stages and induces severe and permanent diabetes. Most morbidity of schistosomiasis mansoni is attributed to a granulomatous inflammatory response and associated liver fibrosis. This study was designed to investigate whether STZ administration and schistosomiasis modify the biodistribution of the radiopharmaceutical sodium (99m)Tc-pertechnetate. Adult female mice were infected by exposure to 100Schistosoma mansoni cercariae (BH strain, Belo Horizonte, Brazil) and euthanized after nine weeks. STZ was administered by a single intraperitoneal injection of 100mg/kg body weight, 3 or 15days before euthanasia. Each animal received 100μl of sodium (Na) (99m)Tc-pertechnetate ((99m)TcO4(-)) (740kBq). The animals were divided into four groups: A, uninfected; B, infected; C, uninfected + STZ; and D, infected + STZ. Blood, brain, thyroid, heart, lungs, liver, spleen, pancreas and kidneys were removed. The radioactivity was counted and the percentage of the injected dose of Na(99m)TcO4 per gram of the organ (% ID/g) was determined. Three days after the STZ injection, there was a decrease of Na(99m)TcO4 uptake by the liver, lungs, pancreas and kidneys (p<0.05) in group D when compared with group A. After 15days, the decrease of Na(99m)TcO4 uptake occurred also in the brain, thyroid, heart, spleen and blood (p<0.05) in group D. We demonstrated modifications on the biodistribution of Na(99m)TcO4 due to STZ administration and schistosomiasis, possibly due to physiological alterations in some organs. The biodistribution of radiopharmaceutical Na(99m)TcO4 should be carefully evaluated in subjects with diabetes and/or schistosomiasis infection. Copyright

  13. Technetium-99m colloidal bismuth subcitrate: A novel method for the evaluation of peptic ulcer disease

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vasquez, T.E.; Lyons, K.P.; Raiszadeh, M.

    1984-01-01

    The therapeutic agent colloidal bismuth subcitrate (CBS) selectively binds to peptic ulcers. The authors have developed a method for labeling this agent with Tc-99m. Chromatographic quality control studies of the agent on silica gel coated strips (ITLC-SG) showed that more than 97% of Tc-99m was bound to CBS. During in-vitro stability testing, the radio-label was stable for a minimum of 6 hours. The chromatographic findings are in agreement with the in-vivo distribution of the agent which showed no significant radioactivity in thyroid, kidneys, liver, or bladder. The resulting Tc-99m-CBS solution is administered orally in drinking water. Preliminary animal studies havemore » been conducted on 5 adult 3 kg New Zealand rabbits sedated with 50 mg Ketamine I.M. The rabbits were intubated with I.V. tubing advanced to the stomach. They were given a gastric erosive suspension of 600-1000 mg/kg of pulverized ASA in 10 cc tap water. Four hours later they were given 3-4 mCi of the radiotracer in a 5 cc volume of water. Serial in-vivo images were obtained for 2 hours which included thyroid, abdomen, and urinary bladder. Next the stomachs were excised, opened along the greater curvature, imaged, vigorously washed and reimaged. All 5 rabbits showed avid localized binding of radiotracer which remained fixed even with vigorous washing. Areas of normal appearing mucosa were relatively devoid of radiotracer. This new compound may have significant clinical usefulness in the detection of peptic ulcer disease. In addition, such a non-invasive technique, carrying none of the risks or discomfort of endoscopy could also find application in the evaluation of the response to therapy.« less

  14. Differences between the macroscopic and tracer level chemistry of rhenium and technetium: contrasting cage isomerisation behaviour of Re(I) and Tc(I) carborane complexes.

    PubMed

    Armstrong, Andrea F; Valliant, John F

    2010-09-21

    Carboranes form stable complexes with the [M(CO)(3)](+) (M = (99m)Tc, Re) core and are viable ligands for the development of targeted radiopharmaceuticals. (99m)Tc-carborane complexes were found to exhibit substantially different 1,2-->1,7 cage isomerisation behaviour than their Re counterparts, challenging the validity of the routine use of rhenium as a surrogate for the development of technetium-99m based molecular imaging agents.

  15. Rhenium solubility in borosilicate nuclear waste glass: implications for the processing and immobilization of technetium-99.

    PubMed

    McCloy, John S; Riley, Brian J; Goel, Ashutosh; Liezers, Martin; Schweiger, Michael J; Rodriguez, Carmen P; Hrma, Pavel; Kim, Dong-Sang; Lukens, Wayne W; Kruger, Albert A

    2012-11-20

    The immobilization of technetium-99 ((99)Tc) in a suitable host matrix has proven to be a challenging task for researchers in the nuclear waste community around the world. In this context, the present work reports on the solubility and retention of rhenium, a nonradioactive surrogate for (99)Tc, in a sodium borosilicate glass. Glasses containing target Re concentrations from 0 to 10,000 ppm [by mass, added as KReO(4) (Re(7+))] were synthesized in vacuum-sealed quartz ampules to minimize the loss of Re from volatilization during melting at 1000 °C. The rhenium was found as Re(7+) in all of the glasses as observed by X-ray absorption near-edge structure. The solubility of Re in borosilicate glasses was determined to be ~3000 ppm (by mass) using inductively coupled plasma optical emission spectroscopy. At higher rhenium concentrations, additional rhenium was retained in the glasses as crystalline inclusions of alkali perrhenates detected with X-ray diffraction. Since (99)Tc concentrations in a glass waste form are predicted to be <10 ppm (by mass), these Re results implied that the solubility should not be a limiting factor in processing radioactive wastes, assuming Tc as Tc(7+) and similarities between Re(7+) and Tc(7+) behavior in this glass system.

  16. Preparation and Evaluation of 99mTc-labeled Tridentate Chelates for Pre-targeting Using Bioorthogonal Chemistry.

    PubMed

    Bilton, Holly A; Ahmad, Zainab; Janzen, Nancy; Czorny, Shannon; Valliant, John F

    2017-02-04

    Pre-targeting combined with bioorthogonal chemistry is emerging as an effective way to create new radiopharmaceuticals. Of the methods available, the inverse electron demand Diels-Alder (IEDDA) cycloaddition between a radiolabeled tetrazines and trans-cyclooctene (TCO) linked to a biomolecule has proven to be a highly effective bioorthogonal approach to imaging specific biological targets. Despite the fact that technetium-99m remains the most widely used isotope in diagnostic nuclear medicine, there is a scarcity of methods for preparing 99m Tc-labeled tetrazines. Herein we report the preparation of a family of tridentate-chelate-tetrazine derivatives and their Tc(I) complexes. These hitherto unknown compounds were radiolabeled with 99m Tc using a microwave-assisted method in 31% to 83% radiochemical yield. The products are stable in saline and PBS and react rapidly with TCO derivatives in vitro. Their in vivo pre-targeting abilities were demonstrated using a TCO-bisphosphonate (TCO-BP) derivative that localizes to regions of active bone metabolism or injury. In murine studies, the 99m Tc-tetrazines showed high activity concentrations in knees and shoulder joints, which was not observed when experiments were performed in the absence of TCO-BP. The overall uptake in non-target organs and pharmacokinetics varied greatly depending on the nature of the linker and polarity of the chelate.

  17. Discovery of rhenium and masurium (technetium) by Ida Noddack-Tacke and Walter Noddack. Forgotten heroes of nuclear medicine.

    PubMed

    Biersack, H-J; Stelzner, F; Knapp, F F

    2015-01-01

    The history of the early identification of elements and their designation to the Mendeleev Table of the Elements was an important chapter in German science in which Ida (1896-1978) and Walter (1893-1960) Noddack played an important role in the first identification of rhenium (element 75, 1925) and technetium (element 43, 1933). In 1934 Ida Noddack was also the first to predict fission of uranium into smaller atoms. Although the Noddacks did not for some time later receive the recognition for the first identification of technetium-99m, their efforts have appropriately more recently been recognized. The discoveries of these early pioneers are even more astounding in light of the limited technologies and resources which were available during this period. The Noddack discoveries of elements 43 and 75 are related to the subsequent use of rhenium-188 (beta/gamma emitter) and technetium-99m (gamma emitter) in nuclear medicine. In particular, the theranostic relationship between these two generator-derived radioisotopes has been demonstrated and offers new opportunities in the current era of personalized medicine.

  18. Comparison of estimated human dose of (68)Ga-MAA with (99m)Tc-MAA based on rat data.

    PubMed

    Shanehsazzadeh, Saeed; Lahooti, Afsaneh; Yousefnia, Hassan; Geramifar, Parham; Jalilian, Amir Reza

    2015-10-01

    (99m)Tc macroaggregated albumin ((99m)Tc-MAA) that had been used as a perfusion agent has been evaluated. In this study, we tried to estimate human absorbed dose of ⁶⁸Ga-MAA via commercially available kit from Pars-Isotopes, based on biodistribution data in wild-type rats, and compare our estimation with the available absorbed dose data from (99m)Tc-MAA. For biodistribution of ⁶⁸Ga-MAA, three rats were sacrificed at each selected times after injection (15, 30, 45, 60, and 120 min) and the percentage of injected dose per gram of each organ was measured by direct counting from rats data from 11 harvested organs. The medical internal radiation dose formulation was applied to extrapolate from rats to human and to project the absorbed radiation dose for various organs in humans. The biodistribution data for ⁶⁸Ga-MAA showed that the most of the activity was taken up by the lung (more than 97 %) in no time. Our dose prediction shows that a 185-MBq injection of ⁶⁸Ga-MAA into humans might result in an estimated absorbed dose of 4.31 mGy in the whole body. The highest absorbed doses are observed in the adrenals, spleen, pancreas, and red marrow with 0.36, 0.34, 0.26, and 0.19 mGy, respectively. Since the (99m)Tc-MAA remains longer than ⁶⁸Ga-MAA in the lung and ⁶⁸Ga-MAA has good image qualities and results in lower amounts of dose delivery to the critical organs such as gonads, red marrow, and adrenals, the use of ⁶⁸Ga-MAA is recommended.

  19. Determination of miloxacin and metabolites in human serum and urine by high-pressure liquid chromatography.

    PubMed Central

    Yoshitake, A; Kawahara, K; Shono, F; Umeda, I; Izawa, A; Komatsu, T

    1980-01-01

    A sensitive and reliable high-pressure liquid chromatography (HPLC) assay for miloxacin and its two principal metabolites, 5,8-dihydro-8-oxo-2H-1,3-dioxolo[4,5-g]quinoline-7-carboxylic acid (M-1) and 1,4-dihydro-1,6-dimethoxy-7-hydroxy-4-oxoquinoline-3-carboxylic acid (M-2), in human serum and urine was developed. A strong anion-exchange Zipax SAX column using a mobile phase of 0.01 M citric acid solution containing 0.03 M sodium nitrate with pH 5.0 was used to achieve separation of the three compounds. The retention times of miloxacin, M-1, and M-2 were 3.8, 9.3, and 5.9 min, respectively. Serum and urine concentrations of these compounds as low as 10 ng/ml were measured. When results from the HPLC assay were compared with those from the microbiological assay of serum and urine samples from human subjects receiving miloxacin orally, the correlation coefficients were 0.94 for the serum and 0.99 for the urine. The HPLC assay method presents an alternative to the microbiological assay and permits future pharmacokinetic investigations of miloxacin. PMID:7416751

  20. Comparative evaluation of technetium-99m-diethylenetriaminepentaacetic acid renal dynamic imaging versus the Modification of Diet in Renal Disease equation and the Chronic Kidney Disease Epidemiology Collaboration equation for the estimation of GFR.

    PubMed

    Huang, Qi; Chen, Yunshuang; Zhang, Min; Wang, Sihe; Zhang, Weiguang; Cai, Guangyan; Chen, Xiangmei; Sun, Xuefeng

    2018-04-01

    We compared the performance of technetium-99m-diethylenetriaminepentaacetic acid ( 99m Tc-DTPA) renal dynamic imaging (RDI), the MDRD equation, and the CKD EPI equation to estimate glomerular filtration rate (GFR). A total of 551 subjects, including CKD patients and healthy individuals, were enrolled in this study. Dual plasma sample clearance method of 99m Tc-DTPA was used as the true value for GFR (tGFR). RDI and the MDRD and CKD EPI equations for estimating GFR were compared and evaluated. Data indicate that RDI and the MDRD equation underestimated GFR and CKD EPI overestimated GFR. RDI was associated with significantly higher bias than the MDRD and CKD EPI equations. The regression coefficient, diagnostic precision, and consistency of RDI were significantly lower than either equation. RDI and the MDRD equation underestimated GFR to a greater degree in subjects with tGFR ≥ 90 ml/min/1.73 m 2 compared with the results obtained from all subjects. In the tGFR60-89 ml/min/1.73 m 2 group, the precision of RDI was significantly lower than that of both equations. In the tGFR30-59 ml/min/1.73 m 2 group, RDI had the least bias, the most precision, and significantly higher accuracy compared with either equation. In tGFR < 30 ml/min/1.73 m 2 , the three methods had similar performance and were not significantly different. RDI significantly underestimates GFR and performs no better than MDRD and CKD EPI equations for GFR estimation; thus, it should not be recommended as a reference standard against which other GFR measurement methods are assessed. However, RDI better estimates GFR than either equation for individuals in the tGFR30-59 ml/min/1.73 m 2 group and thus may be helpful to distinguish stage 3a and 3b CKD.

  1. PREDICTION OF RELAPSE FROM HYPERTHYROIDISM FOLLOWING ANTITHYROID MEDICATION WITHDRAWAL USING TECHNETIUM THYROID UPTAKE SCANNING.

    PubMed

    Nakhjavani, Manouchehr; Abdollahi, Soraya; Farzanefar, Saeed; Abousaidi, Mohammadtagi; Esteghamati, Alireza; Naseri, Maryam; Eftekhari, Mohamad; Abbasi, Mehrshad

    2017-04-02

    Technetium thyroid uptake (TTU) is not inhibited by antithyroid drugs (ATD) and reflects the degree of thyroid stimulation. We intended to predict the relapse rate from hyperthyroidism based on TTU measurement. Out of 44 initially enrolled subjects, 38 patients aged 41.6 ± 14.6 with Graves disease (duration: 84 ± 78 months) completed the study. TTU was performed with 40-second imaging of the neck and mediastinum 20 minutes after injection of 1 mCi technetium-99m pertechnetate. TTU was measured as the percentage of the count of activity accumulated in the thyroidal region minus the mediastinal background uptake to the count of 1 mCi technetium-99m under the same acquisition conditions. Then methimazole was stopped and patients were followed. The optimal TTU cutoff value for Graves relapse prediction was calculated using Youden's J statistic. Hyperthyroidism relapsed in 11 (28.9%) patients 122 ± 96 (range: 15-290) days post-ATD withdrawal. The subjects in remission were followed for 209 ± 81 days (range: 88-390). TTU was significantly higher in patients with forthcoming relapse (12.0 ± 8.0 vs. 3.9 ± 2.0, P = .007). The difference was significant after adjustment for age, sex, history of previous relapse, disease duration, and thyroid-stimulating hormone (TSH) levels before withdrawal. The area under the receiver operative characteristic (ROC) curve was 0.87. The optimal TTU cutoff value for classification of subjects with relapse and remission was 8.7 with sensitivity, specificity, and positive and negative predictive value of 73%, 100%, 100%, and 90%, respectively (odds ratio [OR] = 10.0; 95% confidence interval [CI]: 3.4-29.3). TTU evaluation in hyperthyroid patients receiving antithyroid medication is an accurate and practical method for predicting relapse after ATD withdrawal. ATD = antithyroid drugs RIU = radio-iodine uptake TSH = thyroid-stimulating hormone TSI = thyroid-stimulating immunoglobulin TTU = technetium thyroid uptake.

  2. 99mTc-EDDA/HYNIC-TOC in management of patients with head and neck somatostatin receptor positive tumors.

    PubMed

    Trogrlic, Mate; Tezak, Stanko

    2016-01-01

    Aim of this study was to determine the value of technetium-99m-hydrazinonicotinyl-Tyr3-octreotide (99mTc-ED-DA/HYNIC-TOC) in patients with somatostatin receptor (SSR) positive tumors of head and neck region. A total number of 16 patients were enrolled in this study. Planar whole body (WB) and single photon emission computed tomography (SPECT) images were acquired at 2 and 4 hours after the injection of approximately 670 MBq of 99mTc-EDDA/HYNIC-TOC. Additional single photon emission computed tomography/computed tomography (SPECT/CT) images of the head and neck region were acquired at 4h post tracer injection. Clinical and imaging follow up were taken as the reference standard. There were 10 female and 6 male patients of age 57.7 ± 12.9 years (58.5; 32-78) years. 99mTc-EDDA/HYNIC-TOC somatostatin receptor scintigraphy (SRS) was TP in 13 patients, TN in two and FP in one. Follow up period for SRS was 31.1 ± 19.4 (29; 2-63) months. 99mTc-EDDA/HYNIC-TOC scintigraphy provided additional information in 50% of patients, with impact on patient management in the same percentage of patients. Distant metastases were found in nine out of 16 patients (56%). 99mTc-EDDA/HYNIC-TOC SRS had sensitivity of 100% (75.3-100%), specificity of 66.7% (9.4-99.2%), accuracy of 93.7%, positive predictive value of 92.9% (66.1-99.8%), and negative predictive value of 100% (15.8-100%). Somatostatin receptor scintigraphy using 99mTc-EDDA/HYNIC-TOC is very useful imaging method in the evalu-ation of patients with SSR positive tumors of head and neck region.

  3. Single chain variable fragment displaying M13 phage library functionalized magnetic microsphere-based protein equalizer for human serum protein analysis.

    PubMed

    Zhu, Guijie; Zhao, Peng; Deng, Nan; Tao, Dingyin; Sun, Liangliang; Liang, Zhen; Zhang, Lihua; Zhang, Yukui

    2012-09-18

    Single chain variable fragment (scFv) displaying the M13 phage library was covalently immobilized on magnetic microspheres and used as a protein equalizer for the treatment of human serum. First, scFv displaying M13 phage library functionalized magnetic microspheres (scFv@M13@MM) was incubated with a human serum sample. Second, captured proteins on scFv@M13@MM were eluted with 2 M NaCl, 50 mM glycine-hydrochloric acid (Gly-HCl), and 20% (v/v) acetonitrile with 0.5% (v/v) trifluoroacetic acid in sequence. Finally, the tightly bonded proteins were released by the treatment with thrombin. The eluates were first analyzed by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE) with silver staining. Results indicated that the difference of protein concentration was reduced obviously in NaCl and Gly-HCl fractions compared with untreated human serum sample. The eluates were also digested with trypsin, followed by online 2D-strong cation exchange (SCX)-RPLC-ESI-MS/MS analysis. Results demonstrated that the number of proteins identified from an scFv@M13@MM treated human serum sample was improved 100% compared with that from the untreated sample. In addition, the spectral count of 10 high abundance proteins (serum albumin, serotransferrin, α-2-macroglobulin, α-1-antitrypsin, apolipoprotein B-100, Ig γ-2 chain C region, haptoglobin, hemopexin, α-1-acid glycoprotein 1, and α-2-HS-glycoprotein) decreased evidently after scFv@M13@MM treatment. All these results demonstrate that scFv@M13@MM could efficiently remove high-abundance proteins, reduce the protein concentration difference of human serum, and result in more protein identification.

  4. Influence of proton-pump inhibitors on stomach wall uptake of 99mTc-tetrofosmin in cadmium-zinc-telluride SPECT myocardial perfusion imaging.

    PubMed

    Mouden, Mohamed; Rijkee, Karlijn S; Schreuder, Nanno; Timmer, Jorik R; Jager, Pieter L

    2015-02-01

    Proton-pump inhibitors (PPIs) induce potentially interfering stomach wall activity in single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) with technetium-99m ((99m)Tc)-sestamibi. However, no data are available for (99m)Tc-tetrofosmin. We assessed the influence of prolonged (>2 weeks) PPI use on the stomach wall uptake of (99m)Tc-tetrofosmin in patients referred for stress MPI with a cadmium-zinc-telluride-based SPECT camera and its relation with dyspepsia symptoms. Consecutive patients (n=127) underwent a 1-day adenosine stress-first SPECT-MPI with (99m)Tc-tetrofosmin, of whom 54 (43%) patients had been on PPIs for more than 2 weeks. Stomach wall activity was identified on stress SPECT using computed tomographic attenuation maps and was scored using a four-point grading scale into clinically relevant (scores 2 or 3) or nonrelevant (scores 0 or 1).Patients on PPIs had stomach wall uptake more frequently as compared with patients not using PPIs (22 vs. 7%, P=0.017). Dyspepsia was similar in both groups. Prolonged use of PPIs is associated with stomach wall uptake of (99m)Tc-tetrofosmin in stress cadmium-zinc-telluride-SPECT images. Gastric symptoms were not associated with stomach wall uptake.

  5. Comparison of (99m)Tc-labeled PR81 and its F(ab')₂ fragments as radioimmunoscintigraphy agents for breast cancer imaging.

    PubMed

    Salouti, Mojtaba; Babaei, Mohammad Hossein; Rajabi, Hossein; Foroutan, Haleh; Rasaee, Mohammad Javad; Rajabi, Ahmad Bitarafan; Mohammadnejad, Javad; Shafiee, Mohammad; Mazidi, Mohammad; Daha, Fariba Johari

    2011-02-01

    We digested anti-MUC1 monoclonal antibody PR81 to produce F(ab')₂ fragments. A comparison was performed between the two radiolabeled PR81 and F(ab')₂ fragments for breast tumor imaging in a mouse model. The optimum conditions for pepsin digestion of PR81 were investigated in terms of enzymes: antibody ratio, digestion time duration and preserved immunoreactivity of the produced fragments. The F(ab')₂ fragments were labeled with Technetium-99m using HYNIC as a chelator and tricine as a co-ligand. The immunoreactivity of the complexes was assessed by radioimmunoassay using MCF7 cells. Biodistribution and imaging studies were performed in female BALB/c mice with breast tumor xenograft at 4, 8 and 24 h post-administration. The PR81 was labeled with technetium-99m in the same way for comparison. The optimum time duration for PR81 digestion was found to be 28 h at an enzyme:antibody weight ratio of 1:20 that resulted in 95.2 ± 4.7% purity. The labeling of intact PR81 and its F(ab')₂ fragments were 87.6 ± 4.2 and 76.1 ± 3.3% after 1 h, respectively (p value <0.05). The percentage of immunoreactivity of F(ab')₂ fragments and intact PR81 were 75.4 ± 2.1% and 85.7 ± 2.9%, respectively (p value <0.05). The biodistribution and imaging studies demonstrated localization of the fragments at 4 h post-administration with high sensitivity and specificity. The results showed that F(ab')₂ fragment of PR81 is more suitable than intact PR81 for safer and more rapid detection of human breast cancer.

  6. Diagnosis of Pediatric Hyperthyroidism: Technetium 99 Uptake Versus Thyroid Stimulating Immunoglobulins

    PubMed Central

    Misra, Madhusmita; Levitsky, Lynne L.

    2015-01-01

    Background: Treatment with antithyroid drugs is effective in conditions of increased thyroid hormone production (mostly Graves' Disease; GD), but not in subacute thyroiditis (SAT) or autoimmune thyroiditis (AIT). Positive thyroid stimulating immunoglobulins (TSI) make GD likely. However, not all children with GD have increased TSI. Uptake studies with 123I or 99Tc (99mTc) provide accurate and rapid diagnosis but are expensive and involve radiation exposure. Our objective was to compare TSI with 99mTc uptake for diagnosis of pediatric hyperthyroidism. Methods: We performed a retrospective chart review of hyperthyroid children who had both TSI estimation and 99mTc uptake assessment at presentation. Based on subsequent laboratory studies and follow-up, 37 had GD and 10 had non-GD thyroiditis. The TSI index was considered positive (TSI+) when it was above the upper limit of normal. 99mTc uptake was considered positive (Tc+) for any uptake >0.4% and negative (and low) (Tc-) for uptake ≤0.4%. Results: Forty-seven youth (83% females), aged 12.3±4.6 years, presented with a suppressed thyrotropin (TSH) and elevated free thyroxine and total triiodothyronine. All 37 patients with GD were Tc+ (100% sensitivity and specificity). The sensitivity of TSI for diagnosing GD was 84%, and the specificity was 100%. Six patients with GD were discordant with Tc+ but TSI–. Elevated TSI correlated with Tc+ (p=0.01) with a degree of agreement (kappa) of 0.69. Conclusion: 99mTc has excellent specificity and sensitivity in diagnosing GD. Given additional costs of 99mTc (two and a half times as much as TSI), it is reasonable to reserve 99mTc uptake assessment for hyperthyroidism of unclear etiology and negative TSI. PMID:25257665

  7. Diagnosis of pediatric hyperthyroidism: technetium 99 uptake versus thyroid stimulating immunoglobulins.

    PubMed

    Baskaran, Charumathi; Misra, Madhusmita; Levitsky, Lynne L

    2015-01-01

    Treatment with antithyroid drugs is effective in conditions of increased thyroid hormone production (mostly Graves' Disease; GD), but not in subacute thyroiditis (SAT) or autoimmune thyroiditis (AIT). Positive thyroid stimulating immunoglobulins (TSI) make GD likely. However, not all children with GD have increased TSI. Uptake studies with (123)I or (99)Tc ((99m)Tc) provide accurate and rapid diagnosis but are expensive and involve radiation exposure. Our objective was to compare TSI with (99m)Tc uptake for diagnosis of pediatric hyperthyroidism. We performed a retrospective chart review of hyperthyroid children who had both TSI estimation and (99m)Tc uptake assessment at presentation. Based on subsequent laboratory studies and follow-up, 37 had GD and 10 had non-GD thyroiditis. The TSI index was considered positive (TSI+) when it was above the upper limit of normal. (99m)Tc uptake was considered positive (Tc+) for any uptake >0.4% and negative (and low) (Tc-) for uptake ≤0.4%. Forty-seven youth (83% females), aged 12.3±4.6 years, presented with a suppressed thyrotropin (TSH) and elevated free thyroxine and total triiodothyronine. All 37 patients with GD were Tc+ (100% sensitivity and specificity). The sensitivity of TSI for diagnosing GD was 84%, and the specificity was 100%. Six patients with GD were discordant with Tc+ but TSI-. Elevated TSI correlated with Tc+ (p=0.01) with a degree of agreement (kappa) of 0.69. (99m)Tc has excellent specificity and sensitivity in diagnosing GD. Given additional costs of (99m)Tc (two and a half times as much as TSI), it is reasonable to reserve (99m)Tc uptake assessment for hyperthyroidism of unclear etiology and negative TSI.

  8. 99mTc-HYNIC-(tricine/EDDA)-FROP peptide for MCF-7 breast tumor targeting and imaging.

    PubMed

    Ahmadpour, Sajjad; Noaparast, Zohreh; Abedi, Seyed Mohammad; Hosseinimehr, Seyed Jalal

    2018-02-19

    Breast cancer is the most common malignancy among women in the world. Development of novel tumor-specific radiopharmaceuticals for early breast tumor diagnosis is highly desirable. In this study we developed 99m Tc-HYNIC-(tricine/EDDA)-Lys-FROP peptide with the ability of specific binding to MCF-7 breast tumor. The FROP-1 peptide was conjugated with the bifunctional chelator hydrazinonicotinamide (HYNIC) and labeled with 99m Tc using tricine/EDDA co-ligand. The cellular specific binding of 99m Tc-HYNIC-FROP was evaluated on different cell lines as well as with blocking experiment on MCF-7 (human breast adenocarcinoma). The tumor targeting and imaging of this labeled peptide were performed on MCF-7 tumor bearing mice. Radiochemical purity for 99m Tc-HYNIC-(tricine/EDDA)-FROP was 99% which was determined with ITLC method. This radiolabeled peptide showed high stability in normal saline and serum about 98% which was monitored with HPLC method. In saturation binding experiments, the binding constant (K d ) to MCF-7 cells was determined to be 158 nM. Biodistribution results revealed that the 99m Tc-HYNIC-FROP was mainly exerted from urinary route. The maximum tumor uptake was found after 30 min post injection (p.i.); however maximum tumor/muscle ratio was seen at 15 min p.i. The tumor uptake of this labeled peptide was specific and blocked by co-injection of excess FROP. According to the planar gamma imaging result, tumor was clearly visible due to the tumor uptake of 99m Tc-HYNIC-(tricine/EDDA)-FROP in mouse after 15 min p.i. The 99m Tc-HYNIC-(tricine/EDDA)-FROP is considered a promising probe with high specific binding to MCF-7 breast cancer cells.

  9. Diversification of 99Mo/99mTc separation: non–fission reactor production of 99Mo as a strategy for enhancing 99mTc availability.

    PubMed

    Pillai, Maroor R A; Dash, Ashutosh; Knapp, Furn F Russ

    2015-01-01

    This paper discusses the benefits of obtaining (99m)Tc from non-fission reactor-produced low-specific-activity (99)Mo. This scenario is based on establishing a diversified chain of facilities for the distribution of (99m)Tc separated from reactor-produced (99)Mo by (n,γ) activation of natural or enriched Mo. Such facilities have expected lower investments than required for the proposed chain of cyclotrons for the production of (99m)Tc. Facilities can receive and process reactor-irradiated Mo targets then used for extraction of (99m)Tc over a period of 2 wk, with 3 extractions on the same day. Estimates suggest that a center receiving 1.85 TBq (50 Ci) of (99)Mo once every 4 d can provide 1.48-3.33 TBq (40-90 Ci) of (99m)Tc daily. This model can use research reactors operating in the United States to supply current (99)Mo needs by applying natural (nat)Mo targets. (99)Mo production capacity can be enhanced by using (98)Mo-enriched targets. The proposed model reduces the loss of (99)Mo by decay and avoids proliferation as well as waste management issues associated with fission-produced (99)Mo.

  10. Sentinel lymph node detection in early cervical cancer with combination 99mTc phytate and patent blue.

    PubMed

    Niikura, Hitoshi; Okamura, Chikako; Akahira, Junichi; Takano, Tadao; Ito, Kiyoshi; Okamura, Kunihiro; Yaegashi, Nobuo

    2004-08-01

    The purpose of this study was to examine sentinel lymph node (SLN) detection in patients with early stage cervical cancer using (99m)Tc phytate and patent blue dye and to compare our method with published findings utilizing other radioisotopic tracers. A total of 20 consecutive patients with cervical cancer scheduled for radical hysterectomy and total pelvic lymphadenectomy at our hospital underwent SLN detection study. The day before surgery, lymphoscintigraphy was performed with injection of 99m-technetium ((99m)Tc)-labeled phytate into the uterine cervix. At surgery, patients underwent lymphatic mapping with a gamma-detecting probe and patent blue injected into the same points as the phytate solution. At least one positive node was detected in 18 patients (90%). A total of 46 sentinel nodes were detected (mean, 2.3; range, 1-5). Most sentinel nodes were in one of the following sites: external iliac (21 nodes), obturator (15 nodes), and parametrial (7 nodes). Eleven (24%) sentinel nodes were detected only through radioactivity and two (4%) were detected only with blue dye. The sensitivity, specificity, and negative predictive value for SLN detection were all 100%. Nine published studies involving 295 patients had a summarized detection rate of 85%. Summarized sensitivity, specificity, and negative predictive value were 93%, 100%, and 99%, respectively. Combination of (99m)Tc phytate and patent blue is effective in SLN detection in early stage cervical cancer.

  11. Biodistribution of free and encapsulated 99mTc-fluconazole in an infection model induced by Candida albicans.

    PubMed

    de Assis, Danielle Nogueira; Araújo, Raquel Silva; Fuscaldi, Leonardo Lima; Fernandes, Simone Odília Antunes; Mosqueira, Vanessa Carla Furtado; Cardoso, Valbert Nascimento

    2018-03-01

    Candida spp is an etiologic agent of fungal infections in hospitals and resistance to treatment with antifungals has been extensively reported. Thus, it is very important to develop formulations that increase effectiveness with low toxicity. In this sense, nanocarriers have been investigated, once they modify drug biodistribution profile. Thus, this study aimed to evaluate the biodistribution of free and encapsulated 99m Tc-fluconazole into nanocapsules (NCs) in an experimental immunosuppressed murine model of Candida albicans infection. Fluconazole was radiolabeled with technetium-99 metastable ( 99m Tc) and encapsulated into conventional ( 99m Tc-Fluconazole-PLA-POLOX) and surface-modified ( 99m Tc-Fluconazole-PLA-PEG) NCs by the interfacial deposition of the preformed biodegradable polymer [poly (D,L-lactic acid) (PLA) and PLA-PEG (polyethyleneglycol)] followed by solvent evaporation. The size distribution and zeta potential of the NCs preparations were determined in a Zetasizer by photon correlation spectroscopy and laser Doppler anemometry, respectively. Free and encapsulated 99m Tc-fluconazole were administered intravenously in immunosuppressed mice bearing a local infection induced by Candida Albicans inoculation in the right thigh muscle. At pre-established time intervals, tissues and organs of interest were removed and radioactivity was measured in an automatic gamma radiation counter. The NCs diameter was between 200 and 400 nm with negative zeta potential values. Free 99m Tc-fluconazole was more rapidly eliminated by the renal system compared to the encapsulated drug in NCs, which remained longer in blood circulation. The uptake of conventional NCs by mononuclear phagocyte system organs was higher than the one demonstrated by the surface-modified NCs. Both NCs remained longer in the infectious focus when compared to free 99m Tc-fluconazole, but the results did not show a significant difference between NC formulations. These data indicate that these NCs

  12. Behavior of technetium-99 in soils and plants. Final report, April 1, 1974--December 31, 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gast, R.G.; Landa, E.R.; Thorvig, L.J.

    Studies described in this report were aimed at establishing the magnitude and mechanisms of /sup 99/Tc sorption by soils and uptake by plants. Results show that /sup 99/Tc was sorbed from solution over a period to two to five weeks by 8 of 11 soils studies. The slow rate of sorption, the lack of sorption by low organic matter soils, the elimination of sorption following sterilization and increased sorption following addition of dextrose all point to a microbial role in the sorption process. However, it has not been established whether this is a direct or indirect role nor is itmore » possible to clearly predict the conditions under which sorption will occur. Results of plant uptake studies show that /sup 99/Tc can be taken up and translocated into the photosynthetic tissue of higher plants with concentrations in seeds being much less than in vegetative tissue. Technetium-99 was also shown to be toxic to plants at low concentrations and evidence suggests that this is a chemically rather than radiologically induced toxicity. However, this remains to be completely resolved as well as whether there is a threshold level of /sup 99/Tc required before toxicity occurs. Studies of short-term, dynamic, aerobic systems indicated that /sup 99/Tc moves through the soil as a relatively large anion exhibiting characteristic miscible displacement with some asymmetric tailing. /sup 99/Tc exhibits greater retention that C1/sup -/, which may be attributed statistically to weak complexion by organic matter. It is unlikely that this retention phenomenon is related to the static sorption activity reported in the first part of this study.« less

  13. Hürthle cell tumor dwelling in hot thyroid nodules: preoperative detection with technetium-99m-MIBI dual-phase scintigraphy.

    PubMed

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A; Lazzi, S

    1998-05-01

    Single injection dual-phase scintigraphy (early and late acquisitions) with 99mTc-MIBI was used to differentiate benign and malignant hot thyroid nodules. Thirteen euthyroid and two hyperthyroid patients displaying a hot thyroid nodule on the 99mTc scan due to an autonomously functioning thyroid nodule (AFTN) underwent early (15-30 min) and late (3-4 hr) thyroid scintigraphy after the administration of 740-1000 MBq 99mTc-MIBI. Visual scoring was done to assess nodular tracer uptake and retention. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late image and the washout rates (WO) from the nodule and thyroidal tissue were measured. All patients underwent thyroid surgery. Histopathology revealed a Hürthle cell tumor in three nodules, a benign adenoma with oxyphilic metaplasia in two nodules and a benign adenoma without oxyphilic cells in the remaining 10 nodules. The Hürthle cell tumor nodules displayed intense and persistent uptake of 99mTc-MIBI (N/T was 2.81 +/- 0.52 and 5.53 +/- 1.06 in early and late images, respectively; WO from the nodule was 12.33 +/- 0.47, WO from the thyroidal tissue was 22.00 +/- 3.56). The benign nodules showed intense uptake in the early image and intense uptake to absent retention in the late image (N/T was 2.94 +/- 1.31 and 1.62 +/- 0.50 in the early and late images, respectively; WO from the nodule was 20.25 +/- 2.92, WO from the thyroidal tissue was 20.33 +/- 2.92). Single injection dual-phase 99mTc-MIBI scintigraphy of the thyroid with AFTN can identify nodules as a result of the activity of a Hürthle cell tumor, since these tumors cause intense and persistent tracer uptake in contrast with a benign AFTN.

  14. Preparation and evaluation of 99mTc-EDDA/HYNIC-[Lys 3]-bombesin for imaging gastrin-releasing peptide receptor-positive tumours.

    PubMed

    Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Rodriguez-Cortés, Jeanette; Pedraza-López, Martha; Ramírez-Iglesias, María Teresa

    2006-04-01

    Bombesin is a peptide that was initially isolated from frog skin and which belongs to a large group of neuropeptides with many biological functions. The human equivalent is gastrin-releasing peptide (GRP), whose receptors are over-expressed in a variety of malignant tumours. To prepare a HYNIC-[Lys 3]-bombesin analogue that could be easily labelled with 99mTc from lyophilized kit formulations and to evaluate its potential as an imaging agent for GRP receptor-positive tumours. HYNIC was conjugated to the epsilon-amino group of Lys 3 residue at the N-terminal region of bombesin via succinimidyl-N-Boc-HYNIC at pH 9.0. 99mTc labelling was performed by addition of sodium pertechnetate solution and 0.2 M phosphate buffer pH 7.0 to a lyophilized formulation. Stability studies were carried out by reversed phase HPLC and ITLC-SG analyses in serum and cysteine solutions. In-vitro internalization was tested using human prostate cancer PC-3 cells with blocked and non-blocked receptors. Biodistribution and tumour uptake were determined in PC-3 tumour-bearing nude mice. 99mTc-EDDA/HYNIC-[Lys 3]-bombesin was obtained with radiochemical purities >93% and high specific activity ( approximately 0.1 GBq.nmol). Results of in-vitro studies demonstrated a high stability in serum and cysteine solutions, specific cell receptor binding and rapid internalization. Biodistribution data showed a rapid blood clearance, with predominantly renal excretion and specific binding towards GRP receptor-positive tissues such as pancreas and PC-3 tumours. 99mTc-EDDA/HYNIC-[Lys 3]-bombesin obtained from lyophilized kit formulations has promising characteristics for the diagnosis of malignant tumours that over-express the GRP receptor.

  15. APPLICATION OF FORMOHYDROXAMIC ACID IN NUCLEAR PROCESSING: SYNTHESIS AND COMPLEXATION WITH TECHNETIUM-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amber Wright; Edward Mausolf; Keri Campbell

    2010-05-01

    Acetohydroxamic acid (AHA) is an organic ligand planned for use in the Uranium Extraction (UREX) process. It reduces neptunium and plutonium, and the resultant hydrophilic complexes are separated from uranium by extraction with tributyl phosphate (TBP) in a hydrocarbon diluent. AHA undergoes hydrolysis to acetic acid which will impede the recycling of nitric acid. During recent discussions of the UREX process, it has been proposed to replace AHA by formohydroxamic acid (FHA). FHA will undergo hydrolysis to formic acid which is volatile, thus allowing the recycling of nitric acid. The reported reduction potentials of AHA and pertechnetate (TcO{sub 4}{sup -})more » indicated that it may be possible for AHA to reduce technetium, altering its fate in the fuel cycle. At UNLV, it has been demonstrated that TcO{sub 4}{sup -} undergoes reductive nitrosylation by AHA under a variety of conditions. The resulting divalent technetium is complexed by AHA to form the pseudo-octahedral trans-aquonitrosyl (diacetohydroxamic)-technetium(II) complex ([Tc{sup II}(NO)(AHA){sub 2}H{sub 2}O]{sup +}). In this paper, we are reporting the synthesis of FHA and its complex formation with technetium along with the characterization of FHA crystals achieved by NMR and IR spectroscopy. Two experiments were conducted to investigate the complexation of FHA with Tc and the results were compared with previous data on AHA. The first experiment involved the elution of Tc from a Reillex HP anion exchange resin, and the second one monitored the complexation of technetium with FHA by UV-visible spectrophotometry.« less

  16. EVALUATION OF VADOSE ZONE TREATMENT TECHNOLOGIES TO IMMOBILIZE TECHNETIUM-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    PETERSEN, S.W.

    2006-03-15

    The Hanford Site End State Vision document (DOE/RL-2003-59) states: ''There should be an aggressive plan to develop technology for remediation of the contamination that could get to the groundwater (particularly the technetium [{sup 99}Tc])''. In addition, there is strong support from the public and regulatory agencies for the above statement, with emphasis on investigation of treatment alternatives. In July 2004, PNNL completed a preliminary evaluation of remediation technologies with respect to their effectiveness and implementability for immobilization of {sup 99}Tc beneath the BC Cribs in the 200 West Area (Truex, 2004). As a result of this evaluation, PNNL recommended treatabilitymore » testing of in situ soil desiccation, because it has the least uncertainty of those technologies evaluated in July 2004 (Treatability Test Outline, September 30, 2004). In 2005, DOE-RL and Fluor Hanford convened an independent technical panel to review alternative remediation technologies, including desiccation, at a three-day workshop in Richland, Washington. The panel was composed of experts in vadose-zone transport, infiltration control, hydrology, geochemistry, environmental engineering, and geology. Their backgrounds include employment in academia, government laboratories, industry, and consulting. Their review, presented in this document, is based upon written reports from Hanford, oral presentations from Hanford staff, and each panel members' years of experience in their particular field of expertise. The purpose of this report is to document the panel's evaluation of various treatment alternatives with potential for minimizing contaminant migration in the deep vadose zone at the Department of Energy Hanford Site. The panel was tasked with assessing the most viable and practical approach and making recommendations for testing. The evaluation of vadose-zone treatment alternatives was conducted to be broadly applicable at a variety of locations at Hanford. However

  17. Non-pertechnetate Technetium Sensor Research and Development

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bryan, Samuel A.; Rapko, Brian M.; Branch, Shirmir D.

    Several significant uncertainties remain regarding the understanding and modeling of the fate and speciation of technicium-99 ( 99Tc) in Hanford waste tanks, glass, and low-temperature waste forms. A significant (2% to 25%) fraction of the 99Tc in the water-soluble portion of the tank waste may be present as one or more non pertechnetate species that have not been identified and to date, cannot be effectively separated from the wastes. This task will provide a sensor specifically tuned to detect the Tc(I)-carbonyl species believed to constitute the main fraction of the non-pertechnetate form of technetium. By direct measurement of the non-pertechnetatemore » species, such a sensor will help reduce the uncertainties in the modeling of the fate and speciation of 99Tc in Hanford tanks and waste forms. This report summarizes work performed in FY2016 that was sponsored by the Department of Energy’s Office of Environmental Management and demonstrates the protocol for using fluorescent Tc(I)-tricarbonyl complex as a means to detect the non-pertechnetate species within tank waste solutions. The protocol was optimized with respect to ligand concentration, solvent choice, reaction temperature and time. This work culminated in the quantitation of Tc(I)-tricarbonyl within a waste simulant, using a standard addition method for measurement. This report also summarizes the synthesis and high-yield preparation of the low-valence technetium species, [Tc(CO) 3(H 2O) 3] +, which will be used as the technetium standard material for the demonstration of the non-pertechnetate species in actual wastes.« less

  18. Imaging study of using radiopharmaceuticals labeled with cyclotron-produced 99mTc.

    PubMed

    Hou, X; Tanguay, J; Vuckovic, M; Buckley, K; Schaffer, P; Bénard, F; Ruth, T J; Celler, A

    2016-12-07

    Cyclotron-produced 99m Tc (CPTc) has been recognized as an attractive and practical substitution of reactor/generator based 99m Tc. However, the small amount of 92-98 Mo in the irradiation of enriched 100 Mo could lead to the production of other radioactive technetium isotopes (Tc-impurities) which cannot be chemically separated. Thus, these impurities could contribute to patient dose and affect image quality. The potential radiation dose caused by these Tc-impurities produced using different targets, irradiation conditions, and corresponding to different injection times have been investigated, leading us to create dose-based limits of these parameters for producing clinically acceptable CPTc. However, image quality has been not considered. The aim of the present work is to provide a comprehensive and quantitative analysis of image quality for CPTc. The impact of Tc-impurities in CPTc on image resolution, background noise, and contrast is investigated by performing both Monte-Carlo simulations and phantom experiments. Various targets, irradiation, and acquisition conditions are employed for investigating the image-based limits of CPTc production parameters. Additionally, the relationship between patient dose and image quality of CPTc samples is studied. Only those samples which meet both dose- and image-based limits should be accepted in future clinical studies.

  19. Imaging study of using radiopharmaceuticals labeled with cyclotron-produced 99mTc

    NASA Astrophysics Data System (ADS)

    Hou, X.; Tanguay, J.; Vuckovic, M.; Buckley, K.; Schaffer, P.; Bénard, F.; Ruth, T. J.; Celler, A.

    2016-12-01

    Cyclotron-produced 99mTc (CPTc) has been recognized as an attractive and practical substitution of reactor/generator based 99mTc. However, the small amount of 92-98Mo in the irradiation of enriched 100Mo could lead to the production of other radioactive technetium isotopes (Tc-impurities) which cannot be chemically separated. Thus, these impurities could contribute to patient dose and affect image quality. The potential radiation dose caused by these Tc-impurities produced using different targets, irradiation conditions, and corresponding to different injection times have been investigated, leading us to create dose-based limits of these parameters for producing clinically acceptable CPTc. However, image quality has been not considered. The aim of the present work is to provide a comprehensive and quantitative analysis of image quality for CPTc. The impact of Tc-impurities in CPTc on image resolution, background noise, and contrast is investigated by performing both Monte-Carlo simulations and phantom experiments. Various targets, irradiation, and acquisition conditions are employed for investigating the image-based limits of CPTc production parameters. Additionally, the relationship between patient dose and image quality of CPTc samples is studied. Only those samples which meet both dose- and image-based limits should be accepted in future clinical studies.

  20. Investigation of radioactivity concentration in spent technetium generators

    NASA Astrophysics Data System (ADS)

    Idriss, Hajo; Salih, Isam; Alaamer, Abdulaziz S.; Eisa, M. H.; Sam, A. K.

    2014-04-01

    This study was carried out to survey and measure radioactivity concentration and estimate radiation dose level at the surface of spent technetium generator columns for the safe final disposal of radioactive waste. High resolution γ-spectrometry with the aid of handheld radiation survey meters has been used. The radioactivity measurements has shown that 238U, 40K and 137Cs were only measurable in one sample whereas 125Sb was found in 14 samples out of total of 20 samples with an activity concentration which ranged from 21 to 7404 with an average value of 1095 Bq/kg. The activity concentration of 125Sb is highly variable indicating that the spent 99mTc generator columns are of different origin. This investigation highlighted the importance of radiation monitoring of spent technetium generators in the country in order to protect workers, and the public from the dangers posed by radioactive waste.

  1. Synthesis and Evaluation of Technetium-99m- and Rhenium-Labeled Inhibitors of the Prostate-Specific Membrane Antigen (PSMA)

    PubMed Central

    Banerjee, Sangeeta R.; Foss, Catherine A.; Castanares, Mark; Mease, Ronnie C.; Byun, Youngjoo; Fox, James J.; Hilton, John; Lupold, Shawn E.; Kozikowski, Alan P.; Pomper, Martin G.

    2012-01-01

    The prostate-specific membrane antigen (PSMA) is increasingly recognized as a viable target for imaging and therapy of cancer. We prepared seven 99mTc/Re-labeled compounds by attaching known Tc/Re chelating agents to an amino-functionalized PSMA inhibitor (lys-NHCONH-glu) with or without a variable length linker moiety. Ki values ranged from 0.17 to 199 nM. Ex vivo biodistribution and in vivo imaging demonstrated the degree of specific binding to engineered PSMA+ PC3 PIP tumors. PC3-PIP cells are derived from PC3 that have been transduced with the gene for PSMA. Despite demonstrating nearly the lowest PSMA inhibitory potency of this series, [99mTc(CO)3(L1)]+ (L1 = (2-pyridylmethyl)2N(CH2)4CH(CO2H)-NHCO-(CH2)6CO-NH-lys-NHCONH-glu) showed the highest, most selective PIP tumor uptake, at 7.9 ± 4.0% injected dose per gram of tissue at 30 min postinjection. Radioactivity cleared from nontarget tissues to produce a PIP to flu (PSMA-PC3) ratio of 44:1 at 120 min postinjection. PSMA can accommodate the steric requirements of 99mTc/Re complexes within PSMA inhibitors, the best results achieved with a linker moiety between the ε amine of the urea lysine and the chelator. PMID:18637669

  2. Effect of increased surface tension and assisted ventilation on /sup 99m/Tc-DTPA clearance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jefferies, A.L.; Kawano, T.; Mori, S.

    1988-02-01

    Experiments were performed to determine the effects of conventional mechanical ventilation (CMV) and high-frequency oscillation (HFO) on the clearance of technetium-99m-labeled diethylenetriamine pentaacetate (/sup 99m/Tc-DTPA) from lungs with altered surface tension properties. A submicronic aerosol of /sup 99m/Tc-DTPA was insufflated into the lungs of anesthetized, tracheotomized rabbits before and 1 h after the administration of the aerosolized detergent dioctyl sodium sulfosuccinate (OT). Rabbits were ventilated by one of four methods: 1) spontaneous breathing; 2) CMV at 12 cmH2O mean airway pressure (MAP); 3) HFO at 12 cmH2O MAP; 4) HFO at 16 cmH2O MAP. Administration of OT resulted in decreasedmore » arterial PO2 (PaO2), increased lung wet-to-dry weight ratios, and abnormal lung pressure-volume relationships, compatible with increased surface tension. /sup 99m/Tc-DTPA clearance was accelerated after OT in all groups. The post-OT rate of clearance (k) was significantly faster (P less than 0.05) in the CMV at 12 cmH2O MAP (k = 7.57 +/- 0.71%/min (SE)) and HFO at 16 cmH2O MAP (k = 6.92 +/- 0.61%/min) groups than in the spontaneously breathing (k = 4.32 +/- 0.55%/min) and HFO at 12 cmH2O MAP (4.68 +/- 0.63%/min) groups. The clearance curves were biexponential in the former two groups. We conclude that pulmonary clearance of /sup 99m/Tc-DTPA is accelerated in high surface tension pulmonary edema, and this effect is enhanced by both conventional ventilation and HFO at high mean airway pressure.« less

  3. Myocardial perfusion imaging with technetium-99m SQ30217: Comparison with thallium-201 and coronary anatomy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seldin, D.W.; Johnson, L.L.; Blood, D.K.

    1989-03-01

    Myocardial perfusion in ten normal volunteers and 20 patients with coronary artery disease documented by recent coronary arteriography was studied with 99mTc-labeled SQ30217 and /sup 201/TI. Plantar /sup 201/TI imaging followed standard treadmill exercise and planar SQ30217 imaging followed upright bicycle exercise, performed to angina, or the same double product achieved on the treadmill test. Upright anterior, 30 degrees left anterior oblique, and 60 degrees left anterior oblique images were obtained for 3, 6, and 9 min, respectively, starting 2 min after injection of 15 mCi of 99mTc SQ30217. A second 15-mCi dose was injected at rest approximately 2 hrmore » later, and the same imaging protocol was followed. No adverse reactions or laboratory abnormalities attributable to SQ30217 were observed. All scans on the normal volunteers were interpreted as normal. Qualitative readings of both tests were equally sensitive for detecting patients with coronary disease (SQ30217 - 16/20, TI - 17/20, p = NS) and identifying abnormal vessels (SQ30217 - 19/45, TI - 21/45, p = NS). Both agents were falsely positive in 1/15 vessels. Ten vascular regions showed persistent abnormalities on resting SQ30217 scans; eight of these were distal to stenoses of at least 90% and three were also abnormal on thallium redistribution images. Hepatic uptake of SQ30217 obscured inferoapical segments in some views in 14/20 patients but did not interfere with abnormal vessel identification.« less

  4. 16-Cyclopentadienyl tricarbonyl 99mTc 16-oxo-hexadecanoic acid: synthesis and evaluation of fatty acid metabolism in mouse myocardium.

    PubMed

    Lee, Byung Chul; Kim, Dong Hyun; Lee, Iljung; Choe, Yearn Seong; Chi, Dae Yoon; Lee, Kyung-Han; Choi, Yong; Kim, Byung-Tae

    2008-06-26

    We synthesized 16-cyclopentadienyl tricarbonyl 99mTc 16-oxo-hexadecanoic acid (99mTc-CpTT-16-oxo-HDA, 1) and investigated its potential as a radiotracer for evaluating fatty acid metabolism in myocardium. Radiotracer 1 was synthesized in 22.6 +/- 6.3% decay-corrected yield by a double ligand transfer reaction between the ferrocene adduct of methyl hexadecanoate ( 2) and Na99mTcO 4 in the presence of Cr(CO)6 and CrCl3, followed by hydrolysis of the methyl ester group. Radiotracer 1 was found to be chemically stable (99% at 6 h) when incubated in human serum. A tissue distribution study in mice showed that high radioactivity accumulated in heart (9.03%ID/g at 1 min and 5.41%ID/g at 5 min postinjection) with rapid clearance and that heart to blood uptake ratios increased with time (2.13 at 5 min and 3.76 at 30 min postinjection). Metabolite analysis of the heart tissues using a simple extraction method showed that 99mTc-CpTT-4-oxo-butyric acid was detected as the major radioactive metabolite by HPLC, suggesting that 1 is metabolized to 99mTc-CpTT-4-oxo-butyric acid via beta-oxidation in myocardium.

  5. Screening for Hepatopulmonary Syndrome in Cirrhotic Patients Using Technetium 99m-macroaggregated Albumin Perfusion Lung Scan (Tc-MAA): Diagnostic Approach and Clinical Correlations.

    PubMed

    Fragaki, Maria; Sifaki-Pistolla, Dimitra; Samonakis, Dimitrios N; Koulentaki, Mairi; Koukouraki, Sofia; Stathaki, Maria; Kouroumalis, Elias

    2017-09-28

    The aims of this study were to prospectively screen cirrhotic patients with arterial blood gas test and albumin perfusion scan, identify those fulfilling the classic hepatopulmonary syndrome (HPS) criteria, correlate with clinical parameters, and evaluate the survival of patients with HPS compared with those without HPS in a genetically homogenous Cretan cirrhotic population. Data on consecutive 102 patients within 1 year were collected and analyzed. All patients underwent a technetium 99m-macroaggregated albumin perfusion lung scan (Tc-MAA). Diagnosis of HPS was based on the presence of the quantitative index Tc-MAA≥6% and a [P(A-a)O2]≥15 mm Hg (≥20 mm Hg for patients over >64 y). In 94/102 patients, complete scintigraphic data were available. In total, 24 (26%) patients fulfilled the diagnostic criteria of HPS; 95.8% of them had mild-to-moderate HPS. In 8 patients the Tc-MAA scintigraphy could not be interpreted. There was no difference in HPS between decompensated (24.6%) and compensated cirrhosis (27.3%). In the multivariate analysis only the quantitative index was significant for the diagnosis of HPS (P=0.001, odds ratio; 95% confidence interval, 7.05; 2.27-21.87). Kaplan- Meier survival curves indicated a similar overall prognosis for patients diagnosed with HPS (P=0.105). HPS is a frequent complication of cirrhosis. Mild-to-moderate HPS has no significant effect on survival of cirrhotic patients. The quantitative Tc-MAA test is a reliable tool for diagnosis.

  6. Targeting hypoxia in tumors using 2-nitroimidazoles with peptidic chelators for technetium-99m: effect of lipophilicity.

    PubMed

    Zhang, X; Su, Z F; Ballinger, J R; Rauth, A M; Pollak, A; Thornback, J R

    2000-01-01

    Tumor hypoxia is an important prognostic factor for response to therapy. Radiolabeled 2-nitroimidazoles have been used for imaging hypoxia, and the octanol/water partition coefficient (P) of these compounds appears to play a crucial role in their suitability for imaging. A series of 11 2-nitroimidazoles coupled to peptidic chelators for (99m)Tc with divergent P was developed and evaluated in an in vitro system. Two classes of N(3)S chelators were used: dialkyl-Gly-Ser-Cys-linker-2-nitroimidazole (Class I) and dialkyl-Gly-Lys(2-nitroimidazole)-Cys (Class II). The chelators were prepared by automated solid-phase peptide synthesis. Xanthine oxidase was able to reduce the 2-nitroimidiazole moiety on the ligands, but the rate of reduction varied 5-fold among the different chelators. The chelators were labeled by transchelation from [(99m)Tc]gluconate at temperatures between 22 and 100 degrees C. The reaction mixtures were analyzed by HPLC and their P values determined. The accumulation of each complex in suspension cultures of Chinese hamster ovary cells incubated under aerobic or extremely hypoxic conditions was determined. Radiochemical yields ranged from 5 to 80% for the 11 compounds. HPLC showed that some of the compounds formed two complexes with (99m)Tc, possibly syn and anti conformations with respect to the Tc=O bond. In general, the Class I chelators labeled more readily than the class II chelators. The P values of the (99m)Tc complexes varied from 0.0002 to 5 and were generally in accordance with predictions based on structure. There were also differences in P as a function of pH; the free acids had a lower P at pH 7.4 than at pH 2.0 due to ionization, whereas the amides did not show this effect. Accumulation levels in aerobic cells were related to P but varied over a narrow range. Four of the 11 compounds showed selective accumulation in hypoxic cells. The peptidic class of 2-nitroimidazoles, with flexible design and convenient solid-phase synthesis, deserves

  7. Rhenium Solubility in Borosilicate Nuclear Waste Glass: Implications for the Processing and Immobilization of Technetium-99

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McCloy, John S.; Riley, Brian J.; Goel, Ashutosh

    2012-10-26

    The immobilization of 99Tc in a suitable host matrix has proved to be an arduous task for the researchers in nuclear waste community around the world. At the Hanford site in Washington State, the total amount of 99Tc in low-activity waste (LAW) is ~1300 kg and the current strategy is to immobilize the 99Tc in borosilicate glass with vitrification. In this context, the present article reports on the solubility/retention of rhenium, a nonradioactive surrogate for 99Tc, in a LAW borosilicate glass. Due to the radioactive nature of technetium, rhenium was chosen as a simulant because of the similarity between theirmore » ionic radii and other chemical aspects. The glasses containing Re (0 – 10,000 ppm by mass) were synthesized in vacuum-sealed quartz ampoules in order to minimize the loss of Re by volatilization during melting at 1000 °C. The rhenium was found to predominantly exist as Re (VII) in all the glasses as observed by X-ray absorption near-edge structure (XANES). The solubility of Re in borosilicate glasses was determined to be ~3000 ppm (by mass) with inductively coupled plasma-optical emission spectroscopy (ICP-OES). At higher rhenium concentrations, some additional material was retained in the glasses in the form of crystalline inclusions that were detected by X-ray diffraction (XRD) and laser ablation-ICP mass spectrometry (LA-ICP-MS). The implications of these results on the immobilization of 99Tc from radioactive wastes in borosilicate glasses have been discussed.« less

  8. Targeted imaging of gastrin-releasing peptide receptors with 99mTc-EDDA/HYNIC-[Lys3]-bombesin: biokinetics and dosimetry in women.

    PubMed

    Santos-Cuevas, Clara L; Ferro-Flores, Guillermina; Arteaga de Murphy, Consuelo; Pichardo-Romero, Pablo A

    2008-08-01

    The gastrin-releasing peptide receptor (GRP-R) is expressed in several normal human tissues and is overexpressed in various human tumors including breast, prostate, small-cell lung cancer and pancreatic cancer. Recently, 99mTc-EDDA/HYNIC-[Lys]-bombesin (99mTc-HYNIC-BN) was reported as a radiopharmaceutical with high stability in human serum, specific cell GRP-R binding and rapid cell internalization. The aim of this study was to determine the biokinetics and dosimetry of 99mTc-HYNIC-BN and the feasibility of using this radiopharmaceutical to image GRP-R in four early breast cancer patients and seven healthy women. Whole-body images were acquired at 20, 90, 180 min, and 24 h after 99mTc-HYNIC-BN administration. The same regions of interest were drawn around source organs on each time frame and regions of interest were converted to activity (conjugate view counting method). The image sequence was used to extrapolate 99mTc-HYNIC-BN time-activity curves in each organ to calculate the total number of disintegrations (N) that occurred in the source regions. N data were the input for the OLINDA/EXM code to calculate internal radiation dose estimates. 99mTc-HYNIC-BN had a rapid blood clearance with mainly renal excretion. No statistically significant differences (P>0.05) in the radiation-absorbed doses among cancer patients and healthy women were observed. The average equivalent doses (n=11) were 24.8+/-8.8 mSv (kidneys), 7.3+/-1.8 mSv (lungs), 6.5+/-4.0 mSv (breast), 2.0+/-0.3 mSv (pancreas), 1.6+/-0.3 mSv (liver), 1.2+/-0.2 mSv (ovaries), and 1.0+/-0.2 mSv (red marrow). The effective dose was 3.3+/-0.6 mSv. The images showed well-differentiated concentration of 99mTc-HYNIC-BN in cancer mammary tissue. All the absorbed doses were comparable with those known for most of the 99mTc studies. 99mTc-HYNIC-BN shows high tumor uptake in breasts with malignant tumors so it is a promising imaging radiopharmaceutical to target site-specific early breast cancer. The results obtained

  9. Comparison of americium-241 and technetium-99m as transmission sources for attenuation correction of thallium-201 SPECT imaging of the heart.

    PubMed

    Ficaro, E P; Fessler, J A; Rogers, W L; Schwaiger, M

    1994-04-01

    This study compares the ability of 241Am and 99mTc to estimate 201Tl attenuation maps while minimizing the loss in the precision of the emission data. A triple-head SPECT system with either an 241Am or 99mTc line source opposite a fan-beam collimator was used to estimate attenuation maps of the thorax of an anthropomorphic phantom. Linear attenuation values at 75 keV for 201Tl were obtained by linear extrapolation of the measured values from 241Am and 99mTc. Lung and soft-tissue estimates from both isotopes showed excellent agreement to within 3% of the measured values for 201Tl. Linear extrapolation did not yield satisfactory estimates for bone from either 241Am (+11.7%) or 99mTc (-15.3%). Patient data were used to estimate the dependence of crosstalk on patient size. Contamination from 201Tl in the transmission window was 5-6 times greater for 241Am compared to 99mTc, while the contamination in the 201Tl data in the transmission-emission detector head (head 1) was 4-5 times greater for 99mTc compared to 241Am. No contamination was detected in the 201Tl emission data of heads 2 and 3 from 241Am, whereas the 99mTc produced a small crosstalk component giving a signal-to-crosstalk ratio near 20:1. Measurements with a fillable chest phantom estimated the mean error introduced into the data from the removal of the crosstalk. Based on the measured data, 241Am is a suitable transmission source for simultaneous transmission-emission tomography for 201Tl cardiac studies.

  10. Quantitative estimation of infarct size by simultaneous dual radionuclide single photon emission computed tomography: comparison with peak serum creatine kinase activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kawaguchi, K.; Sone, T.; Tsuboi, H.

    1991-05-01

    To test the hypothesis that simultaneous dual energy single photon emission computed tomography (SPECT) with technetium-99m (99mTc) pyrophosphate and thallium-201 (201TI) can provide an accurate estimate of the size of myocardial infarction and to assess the correlation between infarct size and peak serum creatine kinase activity, 165 patients with acute myocardial infarction underwent SPECT 3.2 +/- 1.3 (SD) days after the onset of acute myocardial infarction. In the present study, the difference in the intensity of 99mTc-pyrophosphate accumulation was assumed to be attributable to difference in the volume of infarcted myocardium, and the infarct volume was corrected by the ratiomore » of the myocardial activity to the osseous activity to quantify the intensity of 99mTc-pyrophosphate accumulation. The correlation of measured infarct volume with peak serum creatine kinase activity was significant (r = 0.60, p less than 0.01). There was also a significant linear correlation between the corrected infarct volume and peak serum creatine kinase activity (r = 0.71, p less than 0.01). Subgroup analysis showed a high correlation between corrected volume and peak creatine kinase activity in patients with anterior infarctions (r = 0.75, p less than 0.01) but a poor correlation in patients with inferior or posterior infarctions (r = 0.50, p less than 0.01). In both the early reperfusion and the no reperfusion groups, a good correlation was found between corrected infarct volume and peak serum creatine kinase activity (r = 0.76 and r = 0.76, respectively; p less than 0.01).« less

  11. Imaging of Cerebral Amyloid Angiopathy with Bivalent 99mTc-Hydroxamamide Complexes

    NASA Astrophysics Data System (ADS)

    Iikuni, Shimpei; Ono, Masahiro; Watanabe, Hiroyuki; Matsumura, Kenji; Yoshimura, Masashi; Kimura, Hiroyuki; Ishibashi-Ueda, Hatsue; Okamoto, Yoko; Ihara, Masafumi; Saji, Hideo

    2016-05-01

    Cerebral amyloid angiopathy (CAA), characterized by the deposition of amyloid aggregates in the walls of cerebral vasculature, is a major factor in intracerebral hemorrhage and vascular cognitive impairment and is also associated closely with Alzheimer’s disease (AD). We previously reported 99mTc-hydroxamamide (99mTc-Ham) complexes with a bivalent amyloid ligand showing high binding affinity for β-amyloid peptide (Aβ(1-42)) aggregates present frequently in the form in AD. In this article, we applied them to CAA-specific imaging probes, and evaluated their utility for CAA-specific imaging. In vitro inhibition assay using Aβ(1-40) aggregates deposited mainly in CAA and a brain uptake study were performed for 99mTc-Ham complexes, and all 99mTc-Ham complexes with an amyloid ligand showed binding affinity for Aβ(1-40) aggregates and very low brain uptake. In vitro autoradiography of human CAA brain sections and ex vivo autoradiography of Tg2576 mice were carried out for bivalent 99mTc-Ham complexes ([99mTc]SB2A and [99mTc]BT2B), and they displayed excellent labeling of Aβ depositions in human CAA brain sections and high affinity and selectivity to CAA in transgenic mice. These results may offer new possibilities for the development of clinically useful CAA-specific imaging probes based on the 99mTc-Ham complex.

  12. Imaging of Cerebral Amyloid Angiopathy with Bivalent (99m)Tc-Hydroxamamide Complexes.

    PubMed

    Iikuni, Shimpei; Ono, Masahiro; Watanabe, Hiroyuki; Matsumura, Kenji; Yoshimura, Masashi; Kimura, Hiroyuki; Ishibashi-Ueda, Hatsue; Okamoto, Yoko; Ihara, Masafumi; Saji, Hideo

    2016-05-16

    Cerebral amyloid angiopathy (CAA), characterized by the deposition of amyloid aggregates in the walls of cerebral vasculature, is a major factor in intracerebral hemorrhage and vascular cognitive impairment and is also associated closely with Alzheimer's disease (AD). We previously reported (99m)Tc-hydroxamamide ((99m)Tc-Ham) complexes with a bivalent amyloid ligand showing high binding affinity for β-amyloid peptide (Aβ(1-42)) aggregates present frequently in the form in AD. In this article, we applied them to CAA-specific imaging probes, and evaluated their utility for CAA-specific imaging. In vitro inhibition assay using Aβ(1-40) aggregates deposited mainly in CAA and a brain uptake study were performed for (99m)Tc-Ham complexes, and all (99m)Tc-Ham complexes with an amyloid ligand showed binding affinity for Aβ(1-40) aggregates and very low brain uptake. In vitro autoradiography of human CAA brain sections and ex vivo autoradiography of Tg2576 mice were carried out for bivalent (99m)Tc-Ham complexes ([(99m)Tc]SB2A and [(99m)Tc]BT2B), and they displayed excellent labeling of Aβ depositions in human CAA brain sections and high affinity and selectivity to CAA in transgenic mice. These results may offer new possibilities for the development of clinically useful CAA-specific imaging probes based on the (99m)Tc-Ham complex.

  13. Prospective Evaluation of (99m)Tc-sestamibi SPECT/CT for the Diagnosis of Renal Oncocytomas and Hybrid Oncocytic/Chromophobe Tumors.

    PubMed

    Gorin, Michael A; Rowe, Steven P; Baras, Alexander S; Solnes, Lilja B; Ball, Mark W; Pierorazio, Phillip M; Pavlovich, Christian P; Epstein, Jonathan I; Javadi, Mehrbod S; Allaf, Mohamad E

    2016-03-01

    Nuclear imaging offers a potential noninvasive means of determining the histology of renal tumors. The aim of this study was to evaluate the accuracy of technetium-99m ((99m)Tc)-sestamibi single-photon emission computed tomography/x-ray computed tomography (SPECT/CT) for the differentiation of oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) from other renal tumor histologies. In total, 50 patients with a solid clinical T1 renal mass were imaged with (99m)Tc-sestamibi SPECT/CT prior to surgical resection. Preoperative SPECT/CT scans were reviewed by two blinded readers, and their results were compared with centrally reviewed surgical pathology data. Following surgery, 6 (12%) tumors were classified as renal oncocytomas and 2 (4%) as HOCTs. With the exception of 1 (2%) angiomyolipoma, all other tumors were renal cell carcinomas (82%). (99m)Tc-sestamibi SPECT/CT correctly identified 5 of 6 (83.3%) oncocytomas and 2 of 2 (100%) HOCTs, resulting in an overall sensitivity of 87.5% (95% confidence interval [CI], 47.4-99.7%). Only two tumors were falsely positive on SPECT/CT, resulting in a specificity of 95.2% (95% CI, 83.8-99.4%). In summary, (99m)Tc-sestamibi SPECT/CT is a promising imaging test for the noninvasive diagnosis of renal oncocytomas and HOCTs. We found that the imaging test (99m)Tc-sestamibi SPECT/CT can be used to accurately diagnose two types of benign kidney tumors. This test may be eventually used to help better evaluate patients diagnosed with a renal tumor. Copyright © 2015 European Association of Urology. Published by Elsevier B.V. All rights reserved.

  14. Mannosylated dextran derivatives labeled with fac-[M(CO)₃]+ (M = (99m)Tc, Re) for specific targeting of sentinel lymph node.

    PubMed

    Morais, Maurício; Subramanian, Suresh; Pandey, Usha; Samuel, Grace; Venkatesh, Meera; Martins, Manuel; Pereira, Sérgio; Correia, João D G; Santos, Isabel

    2011-04-04

    Despite being widely used in the clinical setting for sentinel lymph node detection (SLND), (99m)Tc-based colloids (e.g., (99m)Tc-human serum albumin colloids) present a set of properties that are far from ideal. Aiming to design novel compounds with improved biological properties, we describe herein the first class of fully characterized (99m)Tc(CO)₃-mannosylated dextran derivatives with adequate features for SLND. Dextran derivatives, containing the same number of pendant mannose units (13) and a variable number (n) of tridentate chelators (9, n = 1; 10, n = 4, 11, n= 12), have been synthesized and fully characterized. Radiolabeled polymers of the type fac-[(99m)Tc(CO)₃(k³-L)] (12, L = 9, 13, L = 10, 14, L = 11) have been obtained quantitatively in high radiochemical purity (≥ 98%) upon reaction of the dextran derivatives with fac-[(99m)Tc(CO)₃(H₂O)₃]+. The highly stable compounds 13 and 14 were identified by comparing their HPLC chromatograms with the ones obtained for the corresponding rhenium surrogates fac-[Re(CO)₃(k³-10)] (13a) and fac-[Re(CO)₃(k³-11)] (14a), which have been characterized both at the chemical (NMR and IR spectroscopy, and HPLC) and physical level (DLS, AFM and LDV). Compounds 13a and 14a present a positive zeta potential (+ 7.1 mV, pH 7.4) and a hydrodynamic diameter in the range 8.4-8.7 nm. Scintigraphic imaging and biodistribution studies in Wistar rats have shown good accumulation in the sentinel node at 60 min postinjection (6.71 ± 2.35%, 13; and 7.53 ± 0.69%, 14), with significant retention up to 180 min. A clear delineation of the sentinel lymph node without significant washout to other regions was observed in the scintigraphic images. The popliteal extraction of 94.47 ± 2.45% for 14 at 1 h postinjection, as compared to 61.81 ± 2.4% for 13, indicated that 14 is a very promising compound to be further explored as SLN imaging agent.

  15. Use of carbonated water in reduction of adjacent gastric activity in 456 consecutive technetium-99m myocardial perfusion imaging studies.

    PubMed

    Thomas, Dustin M; Lee, Joshua S; Charmforoush, Anthony; Rubal, Bernard J; Rosenblatt, Stephen A; Butler, Joshua T; Clemenshaw, Michael; Cheezum, Michael K; Slim, Ahmad M

    2015-12-01

    Small, observational trials have suggested a reduction in adjacent gastric activity with ingestion of soda water in myocardial perfusion imaging (MPI). We report our findings prior to and after implementation of soda water in 467 consecutive MPI studies. Consecutive MPI studies performed at a high-volume facility referred for vasodilator (VD) or exercise treadmill testing (ETT) were retrospectively reviewed before and after implementation of the soda water protocol. Patients undergoing the soda water protocol received 100 ml of soda water administered 30 min prior to image acquisition and after stress. Studies were performed using a same day rest/stress protocol. Incidence of adjacent gastric activity, diaphragmatic attenuation, stress and rest perfusion defects, and major adverse cardiovascular events (MACE) outcomes defined as death, myocardial infarction, stroke, reevaluation for chest pain, and late revascularization (>90 days from MPI) were abstracted using International Classification of Diseases, Ninth Revision (ICD-9) search. Two hundred and eighteen studies were performed prior to implementation of the soda water protocol and 249 studies were performed with the use of soda water. Baseline demographic data were equal between the groups with the exception of more patients undergoing VD stress receiving soda water (p < 0.001). Soda water was not associated with a decreased incidence of adjacent gastric activity with stress (54.7% versus 61.9% with no soda water, p = 0.129) or rest (68.6% versus 69.5% with no soda water, p = 0.919) imaging. Less adjacent gastric activity was observed with patients undergoing ETT who received soda water (42.5% versus 56.9% with no soda water, p = 0.031), but no difference was observed between the groups with VD stress (69.0% versus 68.1% with no soda water, p = 1.000). The use of soda water prior to technetium-99m MPI was associated with lower rates of adjacent gastric activity only in patients undergoing ETT stress but not

  16. The uptake by the canine tibia of the bone-scanning agent 99mTc-MDP before and after an osteotomy.

    PubMed

    Hughes, S; Khan, R; Davies, R; Lavender, P

    1978-11-01

    The residue and extraction of technetium-labelled methylene diphosphonate (99mTc-MDP), a substance used in bone scanning, was examined in the canine tibia and found to be low. Examination of washout curves suggested that there were four compartments in cortical bone, a vascular, a perivascular, a bone fluid and a bone compartment. After an osteotomy in the canine tibia the residue of 99mTc-MDP increased. This was believed to be due to an increase in the blood supply to the bone and to an associated increase in new bone available for exchange. Bone scanning in a fracture is therefore a reflection of the vascular status of the bone being examined and of the uptake by bone. This is dependent on there being an adequate blood supply to the bone and an increased number of mineral-binding sites.

  17. TC-99 Decontaminant from heat treated gaseous diffusion membrane -Phase I, Part B

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L.; Restivo, M.; Duignan, M.

    2017-11-01

    Uranium gaseous diffusion cascades represent a significant environmental challenge to dismantle, containerize and dispose as low-level radioactive waste. Baseline technologies rely on manual manipulations involving direct access to technetium-contaminated piping and materials. There is a potential to utilize novel decontamination technologies to remove the technetium and allow for on-site disposal of the very large uranium converters. Technetium entered these gaseous diffusion cascades as a hexafluoride complex in the same fashion as uranium. Technetium, as the isotope Tc-99, is an impurity that follows uranium in the first cycle of the Plutonium and Uranium Extraction (PUREX) process. The technetium speciation or exactmore » form in the gaseous diffusion cascades is not well defined. Several forms of Tc-99 compounds, mostly the fluorinated technetium compounds with varying degrees of volatility have been speculated by the scientific community to be present in these cascades. Therefore, there may be a possibility of using thermal or leaching desorption, which is independent of the technetium oxidation states, to perform an insitu removal of the technetium as a volatile species and trap the radionuclide on sorbent traps which could be disposed as low-level waste. Based on the positive results of the first part of this work1 the use of steam as a thermal decontamination agent was further explored with a second piece of used barrier material from a different location. This new series of tests included exposing more of the material surface to the flow of high temperature steam through the change in the reactor design, subjecting it to alternating periods of stream and vacuum, as well as determining if a lower temperature steam, i.e., 121°C (250°F) would be effective, too. Along with these methods, one other simpler method involving the leaching of the Tc-99 contaminated barrier material with a 1.0 M aqueous solution of ammonium carbonate, with and without

  18. Ibuprofen induces reduction of the proliferation-seeking radiotracer 99mTc-(V)DMSA uptake in severe epithelial breast hyperplasia without atypia.

    PubMed

    Papantoniou, Vassilios; Tsaroucha, Angeliki; Valsamaki, Pipitsa; Tsiouris, Spyridon; Sotiropoulou, Evangelia; Karianos, Theodore; Marinopoulos, Spyridon; Fothiadaki, Athina; Sotiropoulou, Maria; Archontaki, Aikaterini; Syrgiannis, Konstantinos; Dimitrakakis, Konstantinos; Antsaklis, Aris

    2010-10-01

    The purpose of this study was to investigate if ibuprofen intake can influence mammary uptake of the proliferation-seeking radiotracer technetium 99m-pentavalent dimercaptosuccinic acid (99mTc-(V)DMSA) in women with severe epithelial and atypical epithelial breast hyperplasia. Eight patients with histologically confirmed severe epithelial breast hyperplasia with (n  =  4) and without atypia (n  =  4) were submitted prospectively to 99mTc-(V)DMSA scintimammography before and after a 4-week course of 400 mg ibuprofen daily oral intake. Lesion to background ratios 60 minutes postinjection were calculated and compared (t-test) before and after ibuprofen administration. Prior to ibuprofen, the patients with severe epithelial hyperplasia displayed a significantly higher 99mTc-(V)DMSA uptake ratio compared to those with atypical epithelial hyperplasia (2.40 ± 0.32 vs 1.67 ± 0.09, respectively; p  =  .003). They also exhibited a more substantial percent decline in tracer uptake postibuprofen compared to women with atypical epithelial hyperplasia (62.0 ± 7.1 vs 15.0 ± 0.2, respectively; p  =  .001). Ibuprofen induces significant uptake reduction of the proliferation-seeking radiotracer 99mTc-(V)DMSA in severe epithelial breast hyperplasia without atypia. This agent could therefore constitute a potential imaging tool for monitoring chemoprophylaxis effectiveness in women at the early stages of malignant transformation.

  19. Dual-Labeled Near-Infrared/99mTc Imaging Probes Using PAMAM-Coated Silica Nanoparticles for the Imaging of HER2-Expressing Cancer Cells

    PubMed Central

    Yamaguchi, Haruka; Tsuchimochi, Makoto; Hayama, Kazuhide; Kawase, Tomoyuki; Tsubokawa, Norio

    2016-01-01

    We sought to develop dual-modality imaging probes using functionalized silica nanoparticles to target human epidermal growth factor receptor 2 (HER2)-overexpressing breast cancer cells and achieve efficient target imaging of HER2-expressing tumors. Polyamidoamine-based functionalized silica nanoparticles (PCSNs) for multimodal imaging were synthesized with near-infrared (NIR) fluorescence (indocyanine green (ICG)) and technetium-99m (99mTc) radioactivity. Anti-HER2 antibodies were bound to the labeled PCSNs. These dual-imaging probes were tested to image HER2-overexpressing breast carcinoma cells. In vivo imaging was also examined in breast tumor xenograft models in mice. SK-BR3 (HER2 positive) cells were imaged with stronger NIR fluorescent signals than that in MDA-MB231 (HER2 negative) cells. The increased radioactivity of the SK-BR3 cells was also confirmed by phosphor imaging. NIR images showed strong fluorescent signals in the SK-BR3 tumor model compared to muscle tissues and the MDA-MB231 tumor model. Automatic well counting results showed increased radioactivity in the SK-BR3 xenograft tumors. We developed functionalized silica nanoparticles loaded with 99mTc and ICG for the targeting and imaging of HER2-expressing cells. The dual-imaging probes efficiently imaged HER2-overexpressing cells. Although further studies are needed to produce efficient isotope labeling, the results suggest that the multifunctional silica nanoparticles are a promising vehicle for imaging specific components of the cell membrane in a dual-modality manner. PMID:27399687

  20. Dual-Labeled Near-Infrared/(99m)Tc Imaging Probes Using PAMAM-Coated Silica Nanoparticles for the Imaging of HER2-Expressing Cancer Cells.

    PubMed

    Yamaguchi, Haruka; Tsuchimochi, Makoto; Hayama, Kazuhide; Kawase, Tomoyuki; Tsubokawa, Norio

    2016-07-07

    We sought to develop dual-modality imaging probes using functionalized silica nanoparticles to target human epidermal growth factor receptor 2 (HER2)-overexpressing breast cancer cells and achieve efficient target imaging of HER2-expressing tumors. Polyamidoamine-based functionalized silica nanoparticles (PCSNs) for multimodal imaging were synthesized with near-infrared (NIR) fluorescence (indocyanine green (ICG)) and technetium-99m ((99m)Tc) radioactivity. Anti-HER2 antibodies were bound to the labeled PCSNs. These dual-imaging probes were tested to image HER2-overexpressing breast carcinoma cells. In vivo imaging was also examined in breast tumor xenograft models in mice. SK-BR3 (HER2 positive) cells were imaged with stronger NIR fluorescent signals than that in MDA-MB231 (HER2 negative) cells. The increased radioactivity of the SK-BR3 cells was also confirmed by phosphor imaging. NIR images showed strong fluorescent signals in the SK-BR3 tumor model compared to muscle tissues and the MDA-MB231 tumor model. Automatic well counting results showed increased radioactivity in the SK-BR3 xenograft tumors. We developed functionalized silica nanoparticles loaded with (99m)Tc and ICG for the targeting and imaging of HER2-expressing cells. The dual-imaging probes efficiently imaged HER2-overexpressing cells. Although further studies are needed to produce efficient isotope labeling, the results suggest that the multifunctional silica nanoparticles are a promising vehicle for imaging specific components of the cell membrane in a dual-modality manner.

  1. Cohesive Relations for Surface Atoms in the Iron-Technetium Binary System

    DOE PAGES

    Taylor, Christopher D.

    2011-01-01

    Iron-technetium alloys are of relevance to the development of waste forms for disposition of radioactive technetium-99 obtained from spent nuclear fuel. Corrosion of candidate waste forms is a function of the local cohesive energy () of surface atoms. A theoretical model for calculating is developed. Density functional theory was used to construct a modified embedded atom (MEAM) potential for iron-technetium. Materials properties determined for the iron-technetium system were in good agreement with the literature. To explore the relationship between local structure and corrosion, MEAM simulations were performed on representative iron-technetium alloys and intermetallics. Technetium-rich phases have lower , suggesting thatmore » these phases will be more noble than iron-rich ones. Quantitative estimates of based on numbers of nearest neighbors alone can lead to errors up to 0.5 eV. Consequently, atomistic corrosion simulations for alloy systems should utilize physics-based models that consider not only neighbor counts, but also local compositions and atomic arrangements.« less

  2. Preparation and comparative evaluation of 99m Tc-HYNIC-cNGR and 99m Tc-HYNIC-PEG2 -cNGR as tumor-targeting molecular imaging probes.

    PubMed

    Vats, Kusum; Satpati, Drishty; Sharma, Rohit; Kumar, Chandan; Sarma, Haladhar Dev; Banerjee, Sharmila

    2018-02-01

    The tripeptide sequence asparagine-glycine-arginine (NGR) specifically recognizes aminopeptidase N (APN or CD13) receptors highly expressed on tumor cells and vasculature. Thus, NGR peptides can precisely deliver therapeutic and diagnostic compounds to CD13 expressing cancer sites. In this regard, 2 NGR peptide ligands, HYNIC-c(NGR) and HYNIC-PEG 2 -c(NGR), were synthesized, radiolabeled with 99m Tc, and evaluated in CD13-positive human fibrosarcoma HT-1080 tumor xenografts. The radiotracers, 99m Tc-HYNIC-c(NGR) and 99m Tc-HYNIC-PEG 2 -c(NGR), could be prepared in approximately 95% radiochemical purity and exhibited excellent in vitro and in vivo stability. The radiotracers were hydrophilic in nature with log P values being -2.33 ± 0.05 and -2.61 ± 0.08. The uptake of 2 radiotracers 99m Tc-HYNIC-c(NGR) and 99m Tc-HYNIC-PEG 2 -c(NGR) was similar in nude mice bearing human fibrosarcoma HT-1080 tumor xenografts, which was significantly reduced (P < .05) during blocking studies. The 2 radiotracers being hydrophilic cleared rapidly from blood, liver, and intestine and were excreted through renal pathway. The pharmacokinetics of 99m Tc-labeled HYNIC peptide could not be modulated through introduction of PEG 2 unit, thus posing a challenge for studies with other linkers towards enhanced tumor uptake and retention. Copyright © 2017 John Wiley & Sons, Ltd.

  3. TC-99m MIBI SPECT imaging in patients with lung carcinoma: is it a functional probe of multidrug resistance genes?

    PubMed

    Ak, Ilknur; Gülbaş, Zafer; Ocak, Suna; Kaya, Eser; Alataş, Füsun; Vardareli, Erkan; Metintaş, Muzaffer

    2007-01-01

    Multidrug-resistance (MDR) phenotype concerns altered membrane transport that results in lower cell concentrations of cytotoxic drug in many cancer types, including lung cancer, and is related to the overexpression of a variety of proteins that act as adenosine triphosphate-dependent extrusion pumps. Tc-99m Sestamibi (MIBI) is a transport substrate for P-glycoprotein (Pgp) pump. In this study, we assessed the uptake and clearance of technetium-99m-2-hexakis 2-methoxyisobutylisonitrile (Tc-99m MIBI) from the tumor and its correlation with messenger RNA (mRNA) levels of Pgp, MDR-associated protein (MRP1), and lung resistance protein (LRP) in lung carcinoma. This study was carried out on 19 patients (mean age, 60.1 +/- 2.07 years) with advanced-stage lung carcinoma. The tumor samples obtained by bronchoscopy were assessed to estimate the levels of Pgp, MRP1, and LRP expression on mRNA level by quantitative real-time reverse-transcription polymerase chain reaction. Tc-99m MIBI chest imaging was performed 15 and 180 minutes after injection of 740 MBq Tc-99m MIBI. The early (T/Be) and delayed (T/Bd) Tc-99m MIBI uptakes and washout rate (WR) of Tc-99m MIBI from the tumor were measured. No correlation was found between the T/Be Tc-99m MIBI uptake of tumors (T/Be) and the levels of Pgp mRNA, MRP1 mRNA, and LRP mRNA by reverse-transcription polymerase chain reaction. There was a correlation between the mean T/Bd Tc-99m MIBI uptake and Pgp expression of the tumors (P = 0.001, Spearman rho = - 0.702). There was a correlation between the WR of Tc-99m MIBI from the tumor and Pgp expression of the tumor (P = 0.000, Spearman rho = 0.875). Washout rate of Tc-99m MIBI was not related to the levels of MRP1 mRNA (P = 0.93, Spearman rho = 0.02) or LRP mRNA (P = 0.47, Spearman rho = 0.177). Increased WR of Tc-99m MIBI is related in Pgp over expression of the tumor. Tc-99m MIBI single photon emission computed tomography imaging may be a functional probe of overexpression of Pgp in

  4. Radioguided localisation of impalpable breast lesions using 99m-Technetium macroaggregated albumin: Lessons learnt during introduction of a new technique to guide preoperative localisation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Landman, Joanne; Kulawansa, Sagarika; McCarthy, Michael

    2015-03-15

    Preoperative wire-guided localisation (WGL) of impalpable breast lesions is widely used but can be technically difficult. Risks include wire migration, inaccurate placement, and inadequate surgical margins. Research shows that radioguided occult lesion localisation (ROLL) is quicker, easier, and can improve surgical and cosmetic outcomes. An audited introduction of ROLL was conducted to validate the technique as a feasible alternative to WGL. Fifty patients with single impalpable lesions and biopsy proven malignancy or indeterminate histology underwent WGL followed by intralesional radiopharmaceutical injection of 99m-Technetium macroaggregated albumin. Postprocedural mammography was performed to demonstrate wire position, and scintigraphy to evaluate radiopharmaceutical migration. Lymphoscintigraphymore » and intraoperative sentinel node biopsy were performed if indicated, followed by lesion localisation and excision using a gamma probe. Specimen imaging was performed, with immediate reexcision for visibly inadequate margins. Accurate localisation was achieved in 86% of patients with ROLL compared to 72% with WGL. All lesions were successfully removed, with clear margins in 71.8% of malignant lesions. Reexcision and intraoperative sentinel node localisation rates were equivalent to preaudit figures for WGL. ROLL was easy to perform and problems were infrequent. Inaccurate radiopharmaceutical placement necessitating WGL occurred in four patients. Minor radiopharmaceutical migration was common, but precluded using ROLL in only two cases. ROLL is effective, simple, inexpensive, and easily learnt; however, preoperative confirmation of correct radiopharmaceutical placement using mammography and the gamma probe is important to help ensure successful lesion removal. Insertion of a backup hookwire is recommended during the initial introduction of ROLL.« less

  5. Cold hematoma visualized by technetium-99m labeled red blood cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Beanblossom, M.

    1986-09-01

    A 64-yr-old male was admitted to the hospital with severe abdominal pain associated with vomiting. Upon examination, the patients Hgb was 7.8 with a WBC count of 13.3 band cells of 7 and a recticulocyte count of 3.4, no evidence of gastrointestinal bleeding. The patient's prior history revealed involvement in an automobile accident approx. 10 days prior to this admission. At that time, he suffered multiple contusions and abrasions with a fracture to his left clavicle. Apparently there were no episodes of abdominal pain or vomiting prior to the onset of illness perceived on the day of admission. A liver/spleenmore » scan was done. Four millicuries of /sup 99m/Tc-sulfur colloid were intravenously injected using a bolus injection technique while obtaining multiple dynamic images. The flow study was unremarkable, demonstrating no abnormalities to the great vessels and good perfusion to both organs. Static images of the liver and spleen revealed a straightening or flatness to the lateral border of the spleen with a small diminished area of tracer sulfur colloid localization at the posterolateral aspect of that organ. This finding raised the suspicion that a small subcapsular hematoma had developed at the mid-posterolateral aspect of the spleen. Twenty-four hours after hospital admission, 4 units of packed RBCs were transfused into the patient. Although there was at this time still no evidence of abnormal bleeding, it was felt that because of the strong symptomatic correlation for internal bleeding, a radionuclide bleeding site study should be ordered and immediately performed.« less

  6. Noninvasive evaluation of active lower gastrointestinal bleeding: comparison between contrast-enhanced MDCT and 99mTc-labeled RBC scintigraphy.

    PubMed

    Zink, Stephen I; Ohki, Stephen K; Stein, Barry; Zambuto, Domenic A; Rosenberg, Ronald J; Choi, Jenny J; Tubbs, Daniel S

    2008-10-01

    The purpose of our study was to compare contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning for the evaluation of active lower gastrointestinal bleeding. Over 17 months, 55 patients (32 men, 23 women; age range, 21-92 years) were evaluated prospectively with contrast-enhanced MDCT using 100 mL of iopromide 300 mg I/mL. Technetium-99m-labeled RBC scans were obtained on 41 of 55 patients and select patients underwent angiography for attempted embolization. Each imaging technique was reviewed in a blinded fashion for sensitivity for detection of active bleeding as well as the active lower gastrointestinal bleeding location. Findings were positive on both examinations in eight patients and negative on both examinations in 20 patients. Findings were positive on contrast-enhanced MDCT and negative on (99m)Tc-labeled RBC in two patients; findings were negative on contrast-enhanced MDCT and positive on (99m)Tc-labeled RBC in 11 patients. Statistics showed significant disagreement, with simple agreement = 68.3%, kappa = 0.341, and p = 0.014. Sixteen of 60 (26.7%) contrast-enhanced MDCT scans were positive prospectively, with all accurately localizing the site of bleeding and identification of the underlying lesion in eight of 16 (50%). Nineteen of 41 (46.3%) (99m)Tc-labeled RBC scans were positive. Eighteen of 41 matched patients went on to angiography. In four of these 18 (22.2%) patients, the site of bleeding was confirmed by angiography, but in 14 of 18 (77.8%), the findings were negative. Contrast-enhanced MDCT and (99m)Tc-labeled RBC scanning show significant disagreement for evaluation of active lower gastrointestinal bleeding. Contrast-enhanced MDCT appears effective for detection and localization in cases of active lower gastrointestinal bleeding in which hemorrhage is active at the time of CT.

  7. Evaluation of the biliary and brain distribution of technetium Tc 99m sestamibi in healthy dogs with the ABCB1 wildtype genotype before and after treatment with spinosad.

    PubMed

    MacKay, Christopher S; Mattoon, John S; Roberts, Gregory D; Tucker, Russell L; Morimoto, Trevor R; Mealey, Katrina L

    2012-06-01

    To determine whether the reported drug-drug interaction between the flea medication spinosad and ivermectin is attributable to inhibition of P-glycoprotein by spinosad. 6 healthy adult dogs with the ABCB1 wildtype genotype. The study was conducted as a prospective, masked, randomized crossover design. Six dogs were allocated to 2 groups; each dog served as its own control animal. Dogs in one of the groups received spinosad at the manufacturer's recommended dose; the other group received no treatment. Forty-eight hours later, scintigraphic imaging of the head and abdomen were performed with the radiolabeled P-glycoprotein substrate methoxy-isobutyl-isonitrile (sestamibi) in both groups of dogs. After a washout period of 60 days, the dogs in each group received the alternate treatment, and scintigraphic imaging again was performed 48 hours later. Gallbladder-to-liver and brain-to-neck musculature ratios of technetium Tc 99m sestamibi were calculated for each dog and compared between treatments. No significant differences in gallbladder-to-liver or brain-to-neck musculature ratios were found between treatments. Results provided evidence that spinosad did not inhibit P-glycoprotein function 48 hours after spinosad was administered at the manufacturer's recommended dose. Further investigations will be necessary to elucidate the mechanism of the reported toxic interaction between spinosad and ivermectin.

  8. Estimation of Organ Absorbed Doses in Patients from 99mTc-diphosphonate Using the Data of MIRDose Software

    PubMed Central

    Shahbazi-Gahrouei, Daryoush; Cheki, Mohsen; Moslehi, Masoud

    2012-01-01

    The purpose of this study was to compare estimation of radiation absorbed doses to patients following bone scans with technetium-99m-labeled methylene diphosphonate (MDP) with the estimates given in MIRDose software. In this study, each patient was injected 25 mCi of 99mTc-MDP. Whole-body images from thirty patients were acquired by gamma camera at 10, 60, 90, 180 minutes after 99mTc-MDP injection. To determine the amount of activity in each organ, conjugate view method was applied on images. MIRD equation was then used to estimate absorbed doses in different organs of patients. At the end, absorbed dose values obtained in this study were compared with the data of MIRDose software. The absorbed doses per unit of injected activity (mGy/MBq × 10–4) for liver, kidneys, bladder wall and spleen were 3.86 ± 1.1, 38.73 ± 4.7, 4.16 ± 1.8 and 3.91 ± 1.3, respectively. The results of this study may be useful to estimate the amount of activity that can be administered to the patient and also showed that methods used in the study for absorbed dose calculation is in good agreement with the data of MIRDose software and it is possible to use by a clinician. PMID:23724374

  9. Identification of Hürthle cell tumor by single-injection, double-phase scintigraphy with technetium-99m-sestamibi.

    PubMed

    Vattimo, A; Bertelli, P; Cintorino, M; Burroni, L; Volterrani, D; Vella, A

    1995-05-01

    Early and late (double-phase) scintigraphy with 99mTc-MIBI was used in a comparative study of the scintigraphic aspects of Hürthle cell tumors and other thyroid tumors. Single-injection, dual-phase (15-30 min and 3-4 hr) thyroid scintigraphy with 99mTc-sestamibi (MIBI) was performed on 41 patients who displayed a cold nodule on previous 99mTc scintigraphy. Visual scoring of nodular uptake was done to compare thyroidal and background tracer uptake. In addition, the nodular-to-thyroid (N/T) uptake ratio in the early and late images and the washout rate from the nodule (WON) and thyroidal tissue (WOT) were measured. Cytologic results were obtained for all patients; histopathologic results were obtained for the 20 patients who had surgery. In eight patients (Group A), the nodule displayed intense and persistent uptake of MIBI (N/T = 1.77 +/- 0.46 and 3.20 +/- 1.37; WON = 17.2% +/- 6.3%; WOT = 24.6% +/- 7.5%); histopathology revealed Hürthle cell tumors (two carcinomas and three adenomas) in five surgical patients. In 15 patients (Group B), the nodule displayed intense uptake in the early image with fading activity in the late image (N/T = 1.45 +/- 0.54 and 0.84 +/- 0.30; WON = 30.0% +/- 7.3%; WOT = 24.5% +/- 6.8%); histopathology revealed a colloid nodule (n = 1), papillary carcinoma (n = 4) and follicular carcinoma (n = 5) in 10 surgical patients. In the remaining 18 patients (Group C), the nodule was cold and late images were not acquired. Histopathology revealed colloid nodules (n = 2) and follicular adenoma (n = 3) in five surgical patients. Single-injection, dual-phase MIBI scintigraphy of the thyroid can identify Hürthle cell tumors because these tumors have intense, persistent tracer uptake in contrast to other thyroid tumors.

  10. Evaluation of Technetium Getters to Improve the Performance of Cast Stone

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neeway, James J.; Qafoku, Nikolla P.; Serne, R. Jeffrey

    2015-11-01

    Cast Stone has been selected as the preferred waste form for solidification of aqueous secondary liquid effluents from the Hanford Tank Waste Treatment and Immobilization Plant (WTP) process condensates and low-activity waste (LAW) melter off-gas caustic scrubber effluents. Cast Stone is also being evaluated as a supplemental immobilization technology to provide the necessary LAW treatment capacity to complete the Hanford tank waste cleanup mission in a timely and cost effective manner. One of the major radionuclides that Cast Stone has the potential to immobilize is technetium (Tc). The mechanism for immobilization is through the reduction of the highly mobile Tc(VII)more » species to the less mobile Tc(IV) species by the blast furnace slag (BFS) used in the Cast Stone formulation. Technetium immobilization through this method would be beneficial because Tc is one of the most difficult contaminants to address at the U.S. Department of Energy (DOE) Hanford Site due to its complex chemical behavior in tank waste, limited incorporation in mid- to high-temperature immobilization processes (vitrification, steam reformation, etc.), and high mobility in subsurface environments. In fact, the Tank Closure and Waste Management Environmental Impact Statement for the Hanford Site, Richland, Washington (TC&WM EIS) identifies technetium-99 ( 99Tc) as one of the radioactive tank waste components contributing the most to the environmental impact associated with the cleanup of the Hanford Site. The TC&WM EIS, along with an earlier supplemental waste-form risk assessment, used a diffusion-limited release model to estimate the release of different contaminants from the WTP process waste forms. In both of these predictive modeling exercises, where effective diffusivities based on grout performance data available at the time, groundwater at the 100-m down-gradient well exceeded the allowable maximum permissible concentrations for 99Tc. (900 pCi/L). Recent relatively short-term (63

  11. Synthesis, Characterization, and Preclinical Evaluation of (99m)Tc-Labeled Macrobicyclic and Tricyclic Chelators as Single Photon Emission Computed Tomography Tracer.

    PubMed

    Yadav, Neelam; Chuttani, Krishna; Mishra, Anil K; Singh, Bachcha

    2016-05-01

    The novel tetraaza macrobicyclic chelator 3,6,9,15-tetraazabicyclo[9.3.1]pentadeca-1(15),11,13-triene-2,10-dione (TBPD) and pentaaza macrotricyclic chelator 9-oxa-3,6,12,15,21-pentaazatricyclo[15,3,2,1]trieicos-1(21),17,19-triene-2,7,11,16-tetradione (OPTT) were synthesized, characterized, and radiolabeled with (99m)Tc to produce (99m)Tc-TBPD and (99m)Tc-OPTT. These radiolabeled complexes were prepared with high radiolabeling yield, radiochemical purity, and good in vitro stability up to 24 h. The labeling efficiency of (99m)Tc-TBPD and (99m)Tc-OPTT was found 98% and 97%. In vitro serum stability of (99m)Tc-TBPD was found to be 95.2%, while that of (99m)Tc-OPTT 94.2% up to 24 h. Blood kinetics experiments of (99m)Tc-labeled complexes showed biphasic pattern of blood clearance. About 99.57 ± 0.89% activity of (99m)Tc-TBPD and 99.42 ± 0.88% activity of (9m)Tc-OPTT were cleared off blood stream at 24 h postadministration. The biological half-life of (99m) Tc-TBPD was observed: t1/2(F) 1 h 5 min and t1/2(S) 12 h and biological half-life of (99m)Tc-OPTT was observed: t1/2(F) 1 h 10 min and t1/2(S) 9 h 50 min, respectively. The biodistribution studies revealed that maximum uptake of (99m)Tc-TBPD was found in liver, concluded that excretory pathway is hepatobiliary, while that of (99m)Tc-OPTT was renal as well as hepatobiliary. The negligible activity observed in stomach confirming the stability of radiolabeled complex in biological milieu. In vitro cytotoxicity study of TBPD and OPTT did not show any considerable antiproliferative activity against cancer cells of human cervical SW756, HeLa, and glioblastoma U-87, U373 cell lines. © 2015 John Wiley & Sons A/S.

  12. Imaging of irradiated liver with Tc-99m-sulfur colloid and Tc-99m-IDA

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gelfand, M.J.; Saha, S.; Aron, B.S.

    1981-09-01

    In three cases, irradiated regions of liver failed to concentrate Tc-99m-sulfur colloid. In two of these three, imaging with Tc-99m-acetanilide iminodiacetic acid (IDA) agents within five days showed near normal hepatic uptake of this hepatobiliary imaging agent. The hepatic parenchymal cells may be imaged with Tc-99m-IDA in some irradiated regions of liver, despite loss of reticuloendothelial cell function.

  13. Right ventricle performances with echocardiography and 99mTc myocardial perfusion imaging in pulmonary arterial hypertension patients.

    PubMed

    Liu, Jie; Fei, Lei; Huang, Guang-Qing; Shang, Xiao-Ke; Liu, Mei; Pei, Zhi-Jun; Zhang, Yong-Xue

    2018-05-01

    Right heart catheterization is commonly used to measure right ventricle hemodynamic parameters and is the gold standard for pulmonary arterial hypertension diagnosis; however, it is not suitable for patients' long-term follow-up. Non-invasive echocardiography and nuclear medicine have been applied to measure right ventricle anatomy and function, but the guidelines for the usefulness of clinical parameters remain to be established. The goal of this study is to identify reliable clinical parameters of right ventricle function in pulmonary arterial hypertension patients and analyze the relationship of these clinical parameters with the disease severity of pulmonary arterial hypertension. In this study, 23 normal subjects and 23 pulmonary arterial hypertension patients were recruited from January 2015 to March 2016. Pulmonary arterial hypertension patients were classified into moderate and severe pulmonary arterial hypertension groups according to their mean pulmonary arterial pressure levels. All the subjects were subjected to physical examination, chest X-ray, 12-lead electrocardiogram, right heart catheterization, two-dimensional echocardiography, and technetium 99m ( 99m Tc) myocardial perfusion imaging. Compared to normal subjects, the right heart catheterization indexes including right ventricle systolic pressure, right ventricle end diastolic pressure, pulmonary artery systolic pressure, pulmonary artery diastolic pressure, pulmonary vascular resistance, and right ventricle end systolic pressure increased in pulmonary arterial hypertension patients and were correlated with mean pulmonary arterial pressure levels. Echocardiography parameters, including tricuspid regurgitation peak velocity, tricuspid regurgitation pressure gradient, tricuspid annular plane systolic excursion and fractional area, right ventricle-myocardial performance index, were significantly associated with the mean pulmonary arterial pressure levels in pulmonary arterial hypertension patients

  14. Biological Evaluation of 99mTc-HYNIC-EDDA/tricine-(Ser)-D4 Peptide for Tumor Targeting.

    PubMed

    Kazemi, Ziba; Zahmatkesh, Mona Haddad; Abedi, Seyed Mohammad; Hosseinimehr, Seyed Jalal

    2017-08-24

    D4 small peptide (Leu-Ala-Arg-Leu-Leu-Thr) was selected as an appropriate agent for specific targeting of epidermal growth factor receptor (EGFR). The aim of study was to investigate the 99mTc-labeled D4 peptide for non-small cell lung tumor targeting. HYNIC-(Ser)3-D4 peptide was labeled with 99mTc using mixture of tricine and ethylenediamine diacetic acid (EDDA) as co-ligands. The in vitro cellular uptake of radiolabeled peptide was evaluated by blocking test on human non-small cell lung cancer (A-549) cell line and its biodistribution was evaluated in A-549 xenografted nude mice. This conjugated peptide was labeled with 99mTc in high radiochemical purity and it was highly stable in buffer and serum. The un-blocked to blocked cellular radioactivity ratio was 4- fold that showed a specific binding of this radiolabeled peptide on A-549 cell. Animal biodistribution in A-549 xenografted nude mice showed rapid clearance from blood and other non-target organs. Tumor uptake values as %ID/g (percentage of injection dose per gram of tissue) were 2.47% and 1.30% at 1 and 4 h after injection. This study showed the 99mTc-EDDA/tricine-HYNIC-(Ser)3-D4 peptide had tumor targeting on the non-small cell lung tumor. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  15. Tc-99 Decontamination From Heat Treated Gaseous Diffusion Membrane -Phase I

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Oji, L.; Wilmarth, B.; Restivo, M.

    2017-03-13

    Uranium gaseous diffusion cascades represent a significant environmental challenge to dismantle, containerize and dispose as low-level radioactive waste. Baseline technologies rely on manual manipulations involving direct access to technetium-contaminated piping and materials. There is a potential to utilize novel thermal decontamination technologies to remove the technetium and allow for on-site disposal of the very large uranium converters. Technetium entered these gaseous diffusion cascades as a hexafluoride complex in the same fashion as uranium. Technetium, as the isotope Tc-99, is an impurity that follows uranium in the first cycle of the Plutonium and Uranium Extraction (PUREX) process. The technetium speciation ormore » exact form in the gas diffusion cascades is not well defined. Several forms of Tc-99 compounds, mostly the fluorinated technetium compounds with varying degrees of volatility have been speculated by the scientific community to be present in these cascades. Therefore, there may be a possibility of using thermal desorption, which is independent of the technetium oxidation states, to perform an in situ removal of the technetium as a volatile species and trap the radionuclide on sorbent traps which could be disposed as low-level waste.« less

  16. Breast tumor targeting with (99m)Tc-HYNIC-PR81 complex as a new biologic radiopharmaceutical.

    PubMed

    Salouti, Mojtaba; Rajabi, Hossein; Babaei, Mohammad Hossein; Rasaee, Mohammad Javad

    2008-10-01

    Human epithelial mucin, MUC1, is commonly overexpressed in adenocarcinoma that includes more than 80% of breast cancers. The PR81 is a murine anti-MUC1 monoclonal antibody (MAb) that was prepared against the human breast cancer. We developed an indirect method for labeling of this antibody with (99m)Tc in order to use the new preparation in immunoscintigraphy studies of BALB/c mice bearing breast tumors. The (99m)Tc-PR81 complex was prepared using the HYNIC as a chelator and tricine as a coligand. The labeling efficiency determined by instant thin-layer chromatography (ITLC) was 89.2%+/-4.7%, and radiocolloides measured by cellulose nitrate electrophoresis were 3.4%+/-0.9%. The in vitro stability of labeled product was determined at room temperature by ITLC and in human serum by gel filtration chromatography - 88.3%+/-4.6% and 79.8%+/-5.7% over 24 h, respectively. The integrity of labeled MAb was checked by means of sodium dodecyl sulfate polyacrylamide gel electrophoresis, and no significant fragmentation was seen. The results of cell binding studies showed that both labeled and unlabeled PR81 were able to compete for binding to MCF 7 cells. Biodistribution studies performed in female BALB/c mice with breast tumor xenografts at 4, 16 and 24 h after the (99m)Tc-HYNIC-PR81 injection demonstrated a specific localization of the compound at the site of tumors and minimum accumulation in non target organs. The tumor imaging was performed in BALB/c mice with breast xenograft tumors at 4, 8, 12, 16, 20, 24, 28, 32 and 36 h after the complex injection. The tumors were visualized with high sensitivity after 8 h. The findings showed that the new radiopharmaceutical is a promising candidate for radioimmunoscintigraphy of the human breast cancer.

  17. [Importance of parathyroid SPECT and 99mTc scintigraphy, and of clinical, laboratorial, ultrasonographic and citologic correlation in the pre-operative localization of the parathyroid adenoma - pictorial assay].

    PubMed

    Oliveira, Marco Antônio Condé de; Maeda, Sérgio Setsuo; Dreyer, Patrícia; Lobo, Alberto; Andrade, Victor Piana de; Hoff, Ana O; Biscolla, Rosa Paula Mello; Smanio, Paola; Brandão, Cynthia M A; Vieira, José G

    2010-06-01

    In patients with primary hyperparathyroidism, candidates for surgical intervention, the parathyroid pre-operative localization is of fundamental importance in planning the appropriate surgical approach. The additional acquisition of SPECT and Technetium-99m images, during parathyroid scintigraphy with Sestamibi, is not common practice. Usually, only planar image acquisition, 15 minutes prior and 2 hours after radiopharmaceutical administration, is performed. In our experience, the complete protocol in parathyroid scintigraphy increases the accuracy of pre-operative parathyroid localization. The complete utilization of all available nuclear medicine methods (SPECT e 99mTc) and image interpretation in a multidisciplinary context can improve the accuracy of parathyroid scintigraphy.

  18. Development of Alternative Technetium Waste Forms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Czerwinski, Kenneth

    2013-09-13

    The UREX+1 process is under consideration for the separation of transuranic elements from spent nuclear fuel. The first steps of this process extract the fission product technicium-99 ({sup 99}Tc) into an organic phase containing tributylphosphate together with uranium. Treatment of this stream requires the separation of Tc from U and placement into a suitable waste storage form. A potential candidate waste form involves immobilizing the Tc as an alloy with either excess metallic zirconium or stainless steel. Although Tc-Zr alloys seem to be promising waste forms, alternative materials must be investigated. Innovative studies related to the synthesis and behavior ofmore » a different class of Tc materials will increase the scientific knowledge related to development of Tc waste forms. These studies will also provide a better understanding of the behavior of {sup 99}Tc in repository conditions. A literature survey has selected promising alternative waste forms for further study: technetium metallic alloys, nitrides, oxides, sulfides, and pertechnetate salts. The goals of this project are to 1) synthesize and structurally characterize relevant technetium materials that may be considered as waste forms, 2) investigate material behavior in solution under different conditions of temperature, electrochemical potential, and radiation, and 3) predict the long-term behavior of these materials.« less

  19. 99mTc-EDDA/HYNIC-TOC in the management of medullary thyroid carcinoma.

    PubMed

    Parisella, Maria; D'Alessandria, Calogero; van de Bossche, Bieke; Chianelli, Marco; Ronga, Giuseppe; Papini, Enrico; Mikolajczak, Renata; Letizia, Claudio; De Toma, Giorgio; Veneziani, Augusto; Scopinaro, Francesco; Signore, Alberto

    2004-04-01

    An early diagnosis of distant metastases or local recurrences of medullary thyroid carcinoma (MTC) can be achieved by several conventional radiological modalities (e.g., ultrasonography, computed tomography [CT], and magnetic resonance imaging [MRI] as well as by radioisotopic procedures, such as positron emission tomography (PET), scintigraphy with different types of radiopharmaceuticals, and radiolabeled receptor-ligands in particular. The aim of this study was to evaluate the clinical utility of 99mTc-EDDA/HYNIC-TOC, a new octreotide derivative, to detect recurrences of disease or distant metastases in MTC. Images obtained of 5 patients with high levels of serum calcitonin were compared to findings obtained with other diagnostic procedures: 111In-octreotide, 99mTc-DMSA-V, 18F-flouro-D-deoxyglucose-PET, and CT/MRI. 99mTc-EDDA/HYNIC-TOC was positive in all patients and showed 15 areas of pathological uptake in the cervical and mediastinal regions. 111In-octreotide was positive in 3 of 3 patients and showed 4 areas, compared to 8 of 99mTc-EDDA/HYNIC-TOC. 99mTc-V-DMSA was positive in 3 of 4 patients but showed 6 pathological areas, compared to 13 of 99mTc-EDDA/HYNIC-TOC. 18F-FDG-PET was positive in 5 of 5 patients but showed only 11 areas, compared to 15 of 99mTc-EDDA/HYNIC-TOC. The CT scan was positive in only 2 patients. In conclusion, 99mTc-EDDA/HYNIC-TOC detected more sites of pathological uptake than other modalities, showed better imaging properties than 111In-octreotide, and might be the radiopharmaceutical of choice for providing a rationale for radioisotopic therapy.

  20. Development and characterization of a 99m Tc-tricarbonyl-labelled estradiol derivative obtained by "Click Chemistry" with potential application in estrogen receptors imaging.

    PubMed

    Tejería, María Emilia; Giglio, Javier; Dematteis, Silvia; Rey, Ana

    2017-09-01

    Assessment of the presence of estrogen receptors in breast cancer is crucial for treatment planning. With the objective to develop a potential agent for estrogen receptors imaging, we present the development and characterization of a 99m Tc-tricarbonyl-labelled estradiol derivative. Using ethinylestradiol as starting material, an estradiol derivative bearing a 1,4-disubstituted 1,2,3-triazole-containing tridentate ligand system was synthesized by "Click Chemistry" and fully characterized. Labelling with high yield and radiochemical purity was achieved through the formation of a 99m Tc-tricarbonyl complex. The radiolabelled compound was stable, exhibited moderate binding to plasma protein (approximately 33%) and lipophilicity in the adequate range (logP 1.3 ± 0.1 at pH 7.4). Studies in MCF7 showed promising uptake values (approximately 2%). However, more than 50% of the activity is quickly released from the cell. Biodistribution experiments in normal rats confirmed the expected "in vivo" stability of the radiotracer but showed very high gastrointestinal and liver activity, which is inconvenient for in vivo applications. Taking into consideration the well-documented influence of the chelating system in the physicochemical and biological behaviour of technetium-labelled small biomolecules, research will be continued using the same pharmacophore but different complexation modalities of technetium. Copyright © 2017 John Wiley & Sons, Ltd.

  1. Liver perfusion imaging in patients with primary and metastatic liver malignancy: prospective comparison between 99mTc-MAA spect and dynamic CT perfusion.

    PubMed

    Reiner, Caecilia S; Goetti, Robert; Burger, Irene A; Fischer, Michael A; Frauenfelder, Thomas; Knuth, Alexander; Pfammatter, Thomas; Schaefer, Niklaus; Alkadhi, Hatem

    2012-05-01

    To prospectively analyze the correlation between parameters of liver perfusion from technetium99m-macroaggregates of albumin (99mTc-MAA) single photon emission computed tomography (SPECT) with those obtained from dynamic CT perfusion in patients with primary or metastatic liver malignancy. Twenty-five consecutive patients (11 women, 14 men; mean age 60.9 ± 10.8; range: 32-78 years) with primary (n = 5) or metastatic (n = 20) liver malignancy planned to undergo selective internal radiotherapy underwent dynamic contrast-enhanced CT liver perfusion imaging (four-dimensional spiral mode, scan range 14.8 cm, 15 scans, cycle time 3 seconds) and 99m)Tc-MAA SPECT after intraarterial injection of 180 MBq 99mTc-MAA on the same day. Data were evaluated by two blinded and independent readers for the parameters arterial liver perfusion (ALP), portal venous perfusion (PVP), and total liver perfusion (TLP) from CT, and the 99mTc-MAA uptake-ratio of tumors in relation to normal liver parenchyma from SPECT. Interreader agreements for quantitative perfusion parameters were high for dynamic CT (r = 0.90-0.98, each P < .01) and 99mTc -MAA SPECT (r = 0.91, P < .01). Significant correlation was found between 99mTc-MAA uptake ratio and ALP (r = 0.7, P < .01) in liver tumors. No significant correlation was found between 99mTc-MAA uptake ratio, PVP (r = -0.381, P = .081), and TLP (r = 0.039, P = .862). This study indicates that in patients with primary and metastatic liver malignancy, ALP obtained by dynamic CT liver perfusion significantly correlates with the 99mTc-MAA uptake ratio obtained by SPECT. Copyright © 2012 AUR. Published by Elsevier Inc. All rights reserved.

  2. Global Xenon-133 Emission Inventory Caused by Medical Isotope Production and Derived from the Worldwide Technetium-99m Demand

    NASA Astrophysics Data System (ADS)

    Kalinowski, Martin B.; Grosch, Martina; Hebel, Simon

    2014-03-01

    Emissions from medical isotope production are the most important source of background for atmospheric radioxenon measurements, which are an essential part of nuclear explosion monitoring. This article presents a new approach for estimating the global annual radioxenon emission inventory caused by medical isotope production using the amount of Tc-99m applications in hospitals as the basis. Tc-99m is the most commonly used isotope in radiology and dominates the medical isotope production. This paper presents the first estimate of the global production of Tc-99m. Depending on the production and transport scenario, global xenon emissions of 11-45 PBq/year can be derived from the global isotope demand. The lower end of this estimate is in good agreement with other estimations which are making use of reported releases and realistic process simulations. This proves the validity of the complementary assessment method proposed in this paper. It may be of relevance for future emission scenarios and for estimating the contribution to the global source term from countries and operators that do not make sufficient radioxenon release information available. It depends on sound data on medical treatments with radio-pharmaceuticals and on technical information on the production process of the supplier. This might help in understanding the apparent underestimation of the global emission inventory that has been found by atmospheric transport modelling.

  3. The cleaning and disinfection by heat of bedpans in automatic and semi-automatic machines.

    PubMed Central

    Mostafa, A. B.; Chackett, K. F.

    1976-01-01

    This work is concerned with the cleaning and disinfection by heat of stainless-steel and polypropylene bedpans, which had been soiled with either a biological contaminant, human serum albumin (HSA) labelled with technetium-99m 99m(Tc), or a bacteriological contaminant, streptococcus faecalis mixed with Tc-labelled HSA. Results of cleaning and disinfection achieved with a Test Machine and those achieved by procedures adopted in eight different wards of a general hospital are reported. Bedpan washers installed in wards were found to be less efficient than the Test Machine, at least partly because of inadequate maintenance. Stainless-steel and polypropylene bedpans gave essentially the same results. PMID:6591

  4. Maternal serum alpha-fetoprotein and human chorionic gonadotropin levels in women with human immunodeficiency virus.

    PubMed

    Gross, Susan; Castillo, Wilfrido; Crane, Marilyn; Espinosa, Bialines; Carter, Suzanne; DeVeaux, Richard; Salafia, Carolyn

    2003-04-01

    The purpose of this study was to establish whether there is a correlation between maternal serum genetic screen analyte results in pregnant women with human immunodeficiency virus and corresponding human immunodeficiency virus index values. Medical records of all pregnant women with human immunodeficiency virus who were delivered at Bronx Lebanon Hospital Center from January 2000 through December 2001 were reviewed for maternal serum screen results, viral load, CD4 counts and percent, antiretroviral therapy, opportunistic infections, substance abuse, and other demographic data. Statistical analysis was accomplished with the chi(2) test, Mann-Whitney U test, and Spearman rank correlation test, with a probability value of <.05 considered significant. Of the 98 women with human immunodeficiency virus who were delivered, 49 women (50%) had a maternal serum genetic screen available. Screened and unscreened women had similar severity of human immunodeficiency virus disease, CD4 count and percentage, and viral loads. Serum screen results showed elevations in maternal serum human chorionic gonadotropin (1.43 +/- 1.04 multiples of the median [MoM]; range, 0.2-5.2 MoM) and maternal serum alpha-fetoprotein (1.29 +/- 0.9 MoM; range, 0.5-3.3 MoM) compared with expected values in the general obstetric population. Maternal serum human chorionic gonadotropin was correlated inversely with CD4 count (P =.002) and CD4 percent (P <.0001). Maternal serum alpha-fetoprotein varied directly with viral load (P <.0001). Increasing maternal serum human chorionic gonadotropin and maternal serum alpha-fetoprotein levels in patients with human immunodeficiency virus are correlated with increasing viral load and decreasing CD4 counts.

  5. Human serum reduces mitomycin-C cytotoxicity in human tenon's fibroblasts.

    PubMed

    Crowston, Jonathan G; Wang, Xiao Y; Khaw, Peng T; Zoellner, Hans; Healey, Paul R

    2006-03-01

    To determine the effect of human serum factors on mitomycin-C (MMC) cytotoxicity in cultured human subconjunctival Tenon's capsule fibroblasts. Fibroblast monolayers were treated with 5-minute applications of mitomycin-C (0.4 mg/mL) and incubated in culture medium with or without additional human serum. Fibroblast apoptosis was quantified by direct cell counts based on nuclear morphology, flow cytometry with annexin-V/propidium iodide, and a lactate dehydrogenase release assay. The number of viable fibroblasts and fibroblast proliferation were measured with a colorimetric MTT assay and by bromodeoxyuridine (BrdU) labeling. Mitomycin-C induced significant levels of fibroblast apoptosis. The addition of human serum resulted in a 40% reduction in MMC-induced fibroblast apoptosis (range, 31.3%-55.3%; P = 0.021) as determined by nuclear morphology and a 32.4% reduction measured by annexin-V/PI. There was a corresponding dose-dependent increase in the number of viable fibroblasts. Serum did not restore proliferation in MMC-treated fibroblasts. Factors present in human serum reduce MMC cytotoxicity in cultured human Tenon's fibroblasts. Human serum increased the number of viable fibroblasts by inhibiting MMC-induced fibroblast apoptosis. Serum factors access aqueous humor after trabeculectomy and may therefore influence the clinical outcome of MMC treatment.

  6. Evaluation of 99mTc-MIBI in thyroid gland imaging for the diagnosis of amiodarone-induced thyrotoxicosis

    PubMed Central

    Zhang, Ruiguo

    2017-01-01

    Objective: Amiodarone-induced thyrotoxicosis (AIT) is caused by amiodarone as a side effect of cardiovascular disease treatment. Based on the differences in their pathological and physiological mechanisms, many methods have been developed so far to differentiate AIT subtypes such as colour flow Doppler sonography (CFDS) and 24-h radioiodine uptake (RAIU). However, these methods suffer from inadequate accuracy in distinguishing different types of AITs and sometimes lead to misdiagnosis and delayed treatments. Therefore, there is an unmet demand for an efficient method for accurate classification of AIT. Methods: Technetium-99 methoxyisobutylisonitrile (99mTc-MIBI) thyroid imaging was performed on 15 patients for AIT classification, and the results were compared with other conventional methods such as CFDS, RAIU and 99mTcO4 imaging. Results: High uptake and retention of MIBI in thyroid tissue is characteristic in Type I AIT, while in sharp contrast, low uptake of MIBI in the thyroid tissue was observed in Type II AIT. Mixed-type AIT shows uptake value between Types I and II. MIBI imaging outperforms other methods with a lower misdiagnosis rate. Conclusion: Among the methods evaluated, MIBI imaging enables an accurate identification of Type I, II and mixed-type AITs by showing distinct images for different types of AITs. The results obtained from our selected subjects revealed that MIBI imaging is a reliable method for diagnosis and classification of AITs and MIBI imaging has potential in the treatment of thyroid diseases. Advances in knowledge: 99mTc-MIBI imaging is a useful method for the diagnosis of AIT. It can distinguish different types of AITs especially for mixed-type AIT, which is usually difficult to treat. 99mTc-MIBI has potential advantages over conventional methods in the efficient treatment of AIT. PMID:28106465

  7. [Improvement in nuclear medicine diagnosis of kidney function using 99m technetium mercaptoacetyltriglycine (MAG3)].

    PubMed

    Erpenbach, K; Ebert, A; Wieler, H

    1991-03-01

    Renal scintigraphy and clearance measurement are indispensable in nephro-urologic disorders. A continuous series of 103 sequential scintigraphies and clearance measurements were performed with the new technetium-labelled agent MAG3 (Gamma-kamera, Phillips Tomo Diagnost) and 131I-orthohippuric acid (OIH) using the Oberhausen method (Nucleopan, Siemens). The time-activity curves obtained with the two radionuclides agreed exactly. Reaching a tubular excretion rate of nearly 90%, the clearance of MAG3 differed by no more than 6% from the OIH clearance in 95% of the cases. The factor between clearances of the two radionuclides was determined by means of a commercially available software according to the Oberhausen method and amounted to 0.59 +/- 0.09. The favorable physical properties and high activity of MAG3 permit exact examination of tubular function and better assessment of renal morphology than hippuran-labelled radionuclides. The low radiation dose combined with a better spatial resolution, especially, the constant availability in a nuclear medicine department should give the preference to MAG3.

  8. Comparison of Tc-99m maraciclatide and Tc-99m sestamibi molecular breast imaging in patients with suspected breast cancer.

    PubMed

    O'Connor, Michael K; Morrow, Melissa M B; Hunt, Katie N; Boughey, Judy C; Wahner-Roedler, Dietlind L; Conners, Amy Lynn; Rhodes, Deborah J; Hruska, Carrie B

    2017-12-01

    Molecular breast imaging (MBI) performed with 99m Tc sestamibi has been shown to be a valuable technique for the detection of breast cancer. Alternative radiotracers such as 99m Tc maraciclatide may offer improved uptake in breast lesions. The purpose of this study was to compare relative performance of 99m Tc sestamibi and 99m Tc maraciclatide in patients with suspected breast cancer, using a high-resolution dedicated gamma camera for MBI. Women with breast lesions suspicious for malignancy were recruited to undergo two MBI examinations-one with 99m Tc sestamibi and one with 99m Tc maraciclatide. A radiologist interpreted MBI studies in a randomized, blinded fashion to assign an assessment score (1-5) and measured lesion size. Lesion-to-background (L/B) ratio was measured with region-of-interest analysis. Among 39 analyzable patients, 21 malignant tumors were identified in 21 patients. Eighteen of 21 tumors (86%) were seen on 99m Tc sestamibi MBI and 19 of 21 (90%) were seen on 99m Tc maraciclatide MBI (p = 1). Tumor extent measured with both radiopharmaceuticals correlated strongly with pathologic size ( 99m Tc sestamibi, r = 0.84; 99m Tc maraciclatide, r = 0.81). The L/B ratio in detected breast cancers was similar for the two radiopharmaceuticals: 1.55 ± 0.36 (mean ± S.D.) for 99m Tc sestamibi and 1.62 ± 0.37 (mean ± S.D.) for 99m Tc maraciclatide (p = 0.53). No correlation was found between the L/B ratio and molecular subtype for 99m Tc sestamibi (r s  = 0.12, p = 0.63) or 99m Tc maraciclatide (r s  = -0.12, p = 0.64). Of 20 benign lesions, 10 (50%) were seen on 99m Tc sestamibi and 9 of 20 (45%) were seen on 99m Tc maraciclatide images (p = 0.1). The average L/B ratio for benign lesions was 1.34 ±0.40 (mean ±S.D.) for 99m Tc sestamibi and 1.41 ±0.52 (mean ±S.D.) for 99m Tc maraciclatide (p = 0.75). Overall diagnostic performance was similar for both radiopharmaceuticals. AUC from ROC

  9. 99mTechnetium and methylene blue guided pulmonary nodules resections: preliminary British experience.

    PubMed

    Nardini, Marco; Bilancia, Rocco; Paul, Ian; Jayakumar, Shruti; Papoulidis, Pavlos; ElSaegh, Mohamed; Hartley, Richard; Richardson, Mark; Misra, Pankash; Migliore, Marcello; Dunning, Joel

    2018-02-01

    Subcentimetre pulmonary nodules can be challenging to locate either during video-assisted thoracoscopic surgery (VATS) or by open techniques. In an era of increasing computed tomography scan availability the number of nodules that are identified that are suspicious for malignancy is rising, and thoracic surgeons require a reliable method to locate these nodules intraoperatively. Our aim was to evaluate, for the first time in the UK, resection of pulmonary nodules using radioactive dye labelling. Local research ethics approval was obtained and the study was submitted to the Integrated Research Application System (IRAS). All data were prospectively collected in our dedicated thoracic surgical database and analyzed at the conclusion of the study. This represents a consecutive series of patients, from January 2016 and until April 2017, who underwent this procedure at our institution: James Cook University Hospital, Middlesbrough, United Kingdom. The primary outcome measured was successful resection rate of the target nodules. Twenty-three patients underwent radiolabeled excision of pulmonary nodules, their average age was 61 years (range, 28-79 years), 13 women and 10 men. The average maximum diameter of the nodule was 8 mm (range, 3-16 mm). All patients underwent successful excision of the target lesion (success rate 100%). One patient (4.3%) sustained pneumothorax following the CT-guided injection of the radio-labelled dye and this required chest drainage prior to general anesthesia. We conclude that technetium guided pulmonary nodule resection is a very reliable method for localization and resection of subcentimetre nodules which may be otherwise be difficult to identify.

  10. 99mTechnetium and methylene blue guided pulmonary nodules resections: preliminary British experience

    PubMed Central

    Bilancia, Rocco; Paul, Ian; Jayakumar, Shruti; Papoulidis, Pavlos; ElSaegh, Mohamed; Hartley, Richard; Richardson, Mark; Misra, Pankash; Migliore, Marcello; Dunning, Joel

    2018-01-01

    Background Subcentimetre pulmonary nodules can be challenging to locate either during video-assisted thoracoscopic surgery (VATS) or by open techniques. In an era of increasing computed tomography scan availability the number of nodules that are identified that are suspicious for malignancy is rising, and thoracic surgeons require a reliable method to locate these nodules intraoperatively. Methods Our aim was to evaluate, for the first time in the UK, resection of pulmonary nodules using radioactive dye labelling. Local research ethics approval was obtained and the study was submitted to the Integrated Research Application System (IRAS). All data were prospectively collected in our dedicated thoracic surgical database and analyzed at the conclusion of the study. This represents a consecutive series of patients, from January 2016 and until April 2017, who underwent this procedure at our institution: James Cook University Hospital, Middlesbrough, United Kingdom. The primary outcome measured was successful resection rate of the target nodules. Results Twenty-three patients underwent radiolabeled excision of pulmonary nodules, their average age was 61 years (range, 28–79 years), 13 women and 10 men. The average maximum diameter of the nodule was 8 mm (range, 3–16 mm). All patients underwent successful excision of the target lesion (success rate 100%). One patient (4.3%) sustained pneumothorax following the CT-guided injection of the radio-labelled dye and this required chest drainage prior to general anesthesia. Conclusions We conclude that technetium guided pulmonary nodule resection is a very reliable method for localization and resection of subcentimetre nodules which may be otherwise be difficult to identify. PMID:29607175

  11. Absent 99mTc-MIBI Uptake in the Thyroid Gland during Early Phase of Parathyroid Scintigraphy in Patients with Primary and Secondary Hyperparathyroidism.

    PubMed

    Jovanovska, Anamarija; Stoilovska, Bojana; Mileva, Magdalena; Miladinova, Daniela; Majstorov, Venjamin; Ugrinska, Ana

    2018-05-20

    Thyroid uptake of technetium-99m methoxyisobutylisonitrile ( 99m Tc-MIBI) during parathyroid scintigraphy can be affected by various conditions. To evaluate the frequency of absent 99m Tc-MIBI uptake by the thyroid gland in the early phase of dual-phase parathyroid scintigraphy. The early planar images of dual phase Tc 99m MIBI parathyroid scintigraphy from 217 patients performed between 2014 and 2017 were retrospectively analysed. Patients were divided into two groups. The first group included 147 patients with primary hyperparathyroidism and the second group included 70 patients with chronic renal failure. Patient records, laboratory and ultrasonographic data were analysed in all patients. Descriptive statistic was used for data analysis. Out of all patients in the first group, 18 patients (12.24%) showed absent thyroid uptake. Thyroidectomy was performed in 44.4% of these patients, and the rest of them had some thyroid disease. Only one patient had no thyroid or another chronic disease. In the second group, 8 patients (11.42%) presented with absent thyroid uptake of MIBI. Among them, 5 patients had no history of thyroid disease and had been on hemodialysis programme, and 3 patients had hypothyroidism. Absent 99m Tc-MIBI uptake in the thyroid during the early phase of parathyroid scintigraphy is most frequently related to thyroid disease. A small proportion of patients with chronic renal failure can present with absent 99m Tc-MIBI uptake in the thyroid as well. The mechanism for this alteration is still unclear and needs further investigation.

  12. Potential Ways to Address Shortage Situations of 99Mo/99mTc.

    PubMed

    Filzen, Leah M; Ellingson, Lacey R; Paulsen, Andrew M; Hung, Joseph C

    2017-03-01

    99m Tc, the most common radioisotope used in nuclear medicine, is produced in a nuclear reactor from the decay of 99 Mo. There are only a few aging nuclear reactors around the world that produce 99 Mo, and one of the major contributors, the National Research Universal (Canada), ceased production on October 31, 2016. The National Research Universal produced approximately 40% of the world's 99 Mo supply, so with its shut down, shortages of 99 Mo/ 99m Tc are expected. Methods: Nuclear pharmacies and nuclear medicine departments throughout the United States were contacted and asked to provide their strategies for coping with a shortage of 99 Mo/ 99m Tc. Each of these strategies was evaluated on the basis of its effectiveness for conserving 99m Tc while still meeting the needs of the patients. Results: From the responses, the following 6 categories of strategies, in order of importance, were compiled: contractual agreements with commercial nuclear pharmacies, alternative imaging protocols, changes in imaging schedules, software use, generator management, and reduction of ordered doses or elimination of backup doses. Conclusion: The supply chain of 99 Mo/ 99m Tc is quite fragile; therefore, being aware of the most appropriate coping strategies is crucial. It is essential to build a strong collaboration between the nuclear pharmacy and nuclear medicine department during a shortage situation. With both nuclear medicine departments and nuclear pharmacies implementing viable strategies, such as the ones proposed, the amount of 99m Tc available during a shortage situation can be maximized. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  13. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation

    DOE PAGES

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; ...

    2015-12-29

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curvemore » K 1 = F(1–Aexp(–B/F)) for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.« less

  14. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation.

    PubMed

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H; Gullberg, Grant T

    2017-02-01

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99m Tc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99m Tc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99m Tc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99m Tc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve [Formula: see text] for K 1 values estimated with 99m Tc-tefrofosmin using SPECT and MBF values estimated with 13 N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13 N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99m Tc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99m Tc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2  = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99m Tc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99m Tc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.

  15. Measurement of absolute myocardial blood flow in humans using dynamic cardiac SPECT and 99mTc-tetrofosmin: Method and validation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares

    The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single-photon emission computed tomography (SPECT). Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curvemore » K 1 = F(1–Aexp(–B/F)) for K 1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH 3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH 3 PET. The flow-dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. The estimated flow-extraction parameters for 99mTc-tefrofosmin were found to be A = 0.91 ± 0.11, B = 0.34 ± 0.20 (R 2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44-3.81 mL/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (P < .001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (P = .037). The PS for 99mTc-tefrofosmin was (0.019 ± 0.10)*MBF + (0.32 ± 0.16). Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF.« less

  16. [Simplicity or complexity of the radiopharmaceutical production process in the light of optimization of radiation protection of staff - 99mTc vs. 18F].

    PubMed

    Wrzesień, Małgorzata

    2018-05-22

    A radiopharmaceutical is a combination of a non-radioactive compound with a radioactive isotope. Two isotopes: technetium-99m (99mTc) and fluorine-18 (18F) are worth mentioning on the rich list of isotopes which have found numerous medical applications. Their similarity is limited only to the diagnostic area of applicability. The type and the energy of emitted radiation, the half-life and, in particular, the production method demonstrate their diversity. The 99mTc isotope is produced by a short-lived nuclide generator - molybdenum-99 (99Mo)/99mTc, while 18F is resulting from nuclear reaction occurring in a cyclotron. A relatively simple and easy handling of the 99Mo/99mTc generator, compared to the necessary use a cyclotron, seems to favor the principle of optimizing the radiological protection of personnel. The thesis on the effect of automation of both the 18F isotope production and the deoxyglucose labelling process on the optimization of radiological protection of workers compared to manual procedures during handling of radiopharmaceuticals labelled with 99Tc need to be verified. Measurements of personal dose equivalent Hp(0.07) were made in 5 nuclear medicine departments and 2 radiopharmaceuticals production centers. High-sensitivity thermoluminescent detectors (LiF: Mg, Cu, P - MCP-N) were used to determine the doses. Among the activities performed by employees of both 18F-fluorodeoxyglucose (18F-FDG) production centers and nuclear medicine departments, the manual quality control procedures and labelling of radiopharmaceuticals with 99mTc isotope manifest the greatest contribution to the recorded Hp(0.07). The simplicity of obtaining the 99mTc isotope as well as the complex, but fully automated production process of the 18F-FDG radiopharmaceutical optimize the radiation protection of workers, excluding manual procedures labelling with 99mTc or quality control of 18F-FDG. Med Pr 2018;69(3):317–327. This work is available in Open Access model and licensed

  17. Detection of occult infection following total joint arthroplasty using sequential technetium-99m HDP bone scintigraphy and indium-111 WBC imaging

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Johnson, J.A.; Christie, M.J.; Sandler, M.P.

    1988-08-01

    Preoperative exclusion or confirmation of periprosthetic infection is essential for correct surgical management of patients with suspected infected joint prostheses. The sensitivity and specificity of (/sup 111/In)WBC imaging in the diagnosis of infected total joint prostheses was examined in 28 patients and compared with sequential (/sup 99m/Tc)HDP/(/sup 111/In)WBC scintigraphy and aspiration arthrography. The sensitivity of preoperative aspiration cultures was 12%, with a specificity of 81% and an accuracy of 58%. The sensitivity of (/sup 111/In)WBC imaging alone was 100%, with a specificity of 50% and an accuracy of 65%. When correlated with the bone scintigraphy and read as sequential (/supmore » 99m/Tc)HDP/(/sup 111/In)WBC imaging, the sensitivity was 88%, specificity 95%, and accuracy 93%. This study demonstrates that (/sup 111/In)WBC imaging is an extremely sensitive imaging modality for the detection of occult infection of joint prostheses. It also demonstrates the necessity of correlating (/sup 111/In)WBC images with (/sup 99m/Tc)HDP skeletal scintigraphy in the detection of occult periprosthetic infection.« less

  18. Differential Lung Uptake of 99mTc-HMPAO and 99mTc-Duramycin in the Chronic Hyperoxia Rat Model

    PubMed Central

    Clough, Anne V.; Audi, Said H.; Haworth, Steven T.; Roerig, David L.

    2015-01-01

    Noninvasive radionuclide imaging has the potential to identify and assess mechanisms involved in particular stages of lung injury which occur with acute respiratory distress syndrome, for example. Lung uptake of 99mTc-hexamethylpropyleneamine oxime (HMPAO) is reported to be partially dependent on the redox status of the lung tissue while 99mTc-duramycin, a new marker of cell injury, senses cell death via apoptosis and/or necrosis. Thus, we investigated changes in lung uptake of these agents in rat exposed to hyperoxia for prolonged periods, a common model of acute lung injury. Methods Male Sprague-Dawley rats were pre-exposed to either normoxia (21% O2) or hyperoxia (85% O2) for up to 21 days. For imaging, the rats were anesthetized, injected i.v. with either 99mTc-HMPAO or 99mTc-duramycin (37-74 MBq) and planar images were acquired using a high sensitivity modular gamma camera. Subsequently, 99mTc-macroagreggated albumin (37 MBq, diam=10-40 μm) was injected i.v., imaged, and used to define a lung region-of-interest. The lung to background ratio was used as a measure of lung uptake. Results Hyperoxia exposure resulted in a 74% increase in 99mTc-HMPAO lung uptake, which peaked at 7 days and persisted for the 21 days of exposure. 99mTc-duramycin lung uptake was also maximal at 7 days of exposure but decreased to near control levels by 21 days. The sustained elevation of 99mTc-HMPAO uptake suggests ongoing changes in lung redox status whereas cell death appears to have subsided by 21 days. Conclusion These results suggest the potential use of 99mTc-HMPAO and 99mTc-duramycin as redox and cell-death imaging biomarkers, respectively, for in vivo identification and assessment of different stages of lung injury. PMID:23086010

  19. Measurement of Absolute Myocardial Blood Flow in Humans Using Dynamic Cardiac SPECT and 99mTc-tetrofosmin: Method and Validation

    PubMed Central

    Shrestha, Uttam; Sciammarella, Maria; Alhassen, Fares; Yeghiazarians, Yerem; Ellin, Justin; Verdin, Emily; Boyle, Andrew; Seo, Youngho; Botvinick, Elias H.; Gullberg, Grant T.

    2015-01-01

    Background The objective of this study was to measure myocardial blood flow (MBF) in humans using 99mTc-tetrofosmin and dynamic single photon emission computed tomography (SPECT). Methods Dynamic SPECT using 99mTc-tetrofosmin and dynamic positron emission tomography (PET) was performed on a group of 16 patients. The SPECT data were reconstructed using a 4D-spatiotemporal iterative reconstruction method. The data corresponding to 9 patients were used to determine the flow-extraction curve for 99mTc-tefrofosmin while data from the remaining 7 patients were used for method validation. The nonlinear tracer correction parameters A and B for 99mTc-tefrofosmin were estimated for the 9 patients by fitting the flow-extraction curve K1=F(1−Aexp(−BF)) for K1 values estimated with 99mTc-tefrofosmin using SPECT and MBF values estimated with 13N-NH3 using PET. These parameters were then used to calculate MBF and coronary flow reserve (CFR) in three coronary territories (LAD, RCA, and LCX) using SPECT for an independent cohort of 7 patients. The results were then compared with that estimated with 13N-NH3 PET. The flow dependent permeability surface-area product (PS) for 99mTc-tefrofosmin was also estimated. Results The estimated flow extraction parameters for 99mTc-tefrofosmin was found to be A=0.91±0.11, B=0.34±0.20 (R2 = 0.49). The range of MBF in LAD, RCA, and LCX was 0.44 ml/min/g to 3.81 ml/min/g. The MBF between PET and SPECT in the group of independent cohort of 7 patients showed statistically significant correlation, r = 0.71 (p < 0.001). However, the corresponding CFR correlation was moderate r = 0.39 yet statistically significant (p = 0.037). The PS for 99mTc-tefrofosmin was (0.091 ± 0.10) * MBF = (0.32 ± 0.16). Conclusions Dynamic cardiac SPECT using 99mTc-tetrofosmin and a clinical two-headed SPECT/CT scanner can be a useful tool for estimation of MBF. PMID:26715603

  20. An improved 99mTc-HYNIC-(Ser)3-LTVSPWY peptide with EDDA/tricine as co-ligands for targeting and imaging of HER2 overexpression tumor.

    PubMed

    Khodadust, Fatemeh; Ahmadpour, Sajjad; Aligholikhamseh, Nazan; Abedi, Seyed Mohammad; Hosseinimehr, Seyed Jalal

    2018-01-20

    Overexpression of human epidermal receptor 2 (HER2) has given the opportunity for targeting and delivering of imaging radiotracers. The aim of this study was to evaluate the 99m Tc-HYNIC-(EDDA/tricine)-(Ser) 3 -LTVSPWY peptide for tumor targeting and imaging of tumor with overexpression of HER2. The HYNIC-(Ser) 3 -LTVSPWY was labeled with 99m Tc in presence of EDDA/tricine mixture as co-ligands. The in vitro and in vivo studies of this radiolabeled peptide were performed for cellular specific binding and tumor targeting. The high radiochemical purity of 99m Tc-HYNIC (EDDA/tricine)-(Ser) 3 -LTVSPWY was obtained to be 99%. It exhibited high stability in normal saline and human serum. In HER2 binding affinity study, a significant reduction in uptake of radiolabeled peptide (7.7 fold) was observed by blocking SKOV-3 cells receptors with unlabeled peptide. The K D and B max values for this radiolabeled peptide were determined as 3.3 ± 1.0 nM and 2.9 ± 0.3 × 10 6 CPM/pMol, respectively. Biodistribution study revealed tumor to blood and tumor to muscle ratios about 6.9 and 4 respectively after 4 h. Tumor imaging by gamma camera demonstrated considerable high contrast tumor uptake. This developed 99m Tc-HYNIC-(Ser) 3 -LTVSPWY peptide selectively targeted on HER2 tumor and exhibited a high target uptake combined with acceptable low background activity for tumor imaging in mice. The results of this study and its comparison with another study showed that 99m Tc-HYNIC-(EDDA/tricine)-(Ser) 3 -LTVSPWY is much better than previously reported radiolabeled peptide as 99m Tc-CSSS-LTVSPWY for HER2 overexpression tumor targeting and imaging. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  1. Renal Abnormalities Among Egyptian Children With Hemophilia A Using Renal Scintigraphy: Relation to Risk Factors and Disease Severity.

    PubMed

    Hamed, Ahmed Alsaeed; Shalaby, Mennatallah Hatem; El-Kinawy, Nihal Saad; Elamawy, Alaa Adel; Abd El-Ghany, Shereen Mohamed

    2017-07-01

    Many risk factors may contribute to renal disease in patients with hemophilia A. We aimed to evaluate functional and structural renal abnormalities among a group of Egyptian children with severe and moderate hemophilia A using technetium-99m diethylene triamine pentaacetic acid ( 99m Tc-DTPA) and technetium-99 m dimercaptusuccinic acid ( 99m Tc-DMSA) scan. We also aimed to determine the relation between these abnormalities and different risk factors and disease severity. Forty male patients, 16 with severe and 24 with moderate hemophilia A, were enrolled in this study. Their mean age was 10.2 ± 4.3 years (range, 5-17 years). Full history taking, clinical examination, laboratory, and radionuclide investigations including serum creatinine, blood urea nitrogen (BUN), urine analysis, creatinine clearance, 24-hour urinary protein, 99m Tc-DTPA scan, and 99m Tc-DMSA scan were performed to all enrolled patients. Serum creatinine and BUN were normal in all patients, and corrected creatinine clearance was diminished in 2 patients. However, 99m Tc-DTPA results yielded 19 (47.5%) patients with diminished glomerular filtration rate (GFR). Moreover, it showed that 14 (35%) had obstructive uropathy, 15 (37.5%) had obstructive nephropathy, while 11 (27.5%) patients showed normal scan. One patient had atrophy of 1 kidney on 99m Tc-DMSA scan. Among our cohort, 5 (12.5%) patients were hypertensive. Microscopic hematuria was detected in 14 (35%) patients while 72.5% had proteinuria. We found an association between hematuria and hypertension with diminished GFR. Despite normal kidney functions (serum creatinine and BUN), we found a high rate of diminished GFR and obstructive uropathy and nephropathy as detected by 99m Tc-DTPA scan among children with hemophilia A.

  2. Sentinel node detection in cervical cancer with (99m)Tc-phytate.

    PubMed

    Silva, Lucas B; Silva-Filho, Agnaldo L; Traiman, Paulo; Triginelli, Sérgio A; de Lima, Carla Flávia; Siqueira, Cristiano Ferrari; Barroso, Adelanir; Rossi, Telma Maria F F; Pedrosa, Moises Salgado; Miranda, Dairton; Melo, José Renan Cunha

    2005-05-01

    The aim of this study was to investigate the feasibility of sentinel lymph node (SLN) identification using radioisotopic lymphatic mapping with technetium-99 m-labeled phytate in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. Between July 2001 and February 2003, 56 patients with cervical cancer FIGO stage I (n = 53) or stage II (n = 3) underwent sentinel lymph node detection with preoperative lymphoscintigraphy ((99m)Tc-labeled phytate injected into the uterine cervix, at 3, 6, 9, and 12 o'clock, at a dose of 55-74 MBq in a volume of 0.8 ml) and intraoperative lymphatic mapping with a handheld gamma probe. Radical hysterectomy was aborted in three cases because parametrial invasion was found intraoperatively and we performed only sentinel node resection. The remaining 53 patients underwent radical hysterectomy with complete pelvic lymphadenectomy. Sentinel nodes were detected using a handheld gamma-probe and removed for pathological assessment during the abdominal radical hysterectomy and pelvic lymphadenectomy. One or more sentinel nodes were detected in 52 out of 56 eligible patients (92.8%). A total of 120 SLNs were detected by lymphoscintigraphy (mean 2.27 nodes per patient) and intraoperatively by gamma probe. Forty-four percent of SLNs were found in the external iliac area, 39% in the obturator region, 8.3% in interiliac region, and 6.7% in the common iliac area. Unilateral sentinel nodes were found in thirty-one patients (59%). The remaining 21 patients (41%) had bilateral sentinel nodes. Microscopic nodal metastases were confirmed in 17 (32%) cases. In 10 of these patients, only SLNs had metastases. The 98 sentinel nodes that were negative on hematoxylin and eosin were submitted to cytokeratin immunohistochemical analysis. Five (5.1%) micrometastases were identified with this technique. The sensitivity of the sentinel node was 82.3% (CI 95% = 56.6-96.2) and the negative predictive value was 92

  3. Use of blood-pool imaging in evaluation of diffuse activity patterns in technetium-99m pyrophosphate myocardial scintigraphy.

    PubMed

    Cowley, M J; Mantle, J A; Rogers, W J; Russell, R O; Rackley, C E; Logic, J R

    1979-06-01

    It has been suggested that diffuse Tc-99m pyrophosphate precordial activity may be due to persistent blood-pool activity in routine delayed views during myocardial imaging. To answer this question, we reviewed myocardial scintigrams recorded 60--90 min following the injection of 12--15 mCi of Tc-99m pyrophosphate for the presence of diffuse precordial activity, and compared these with early images of the blood pool in 265 patients. Diffuse activity in the delayed images was identified in 48 patients: in 20 with acute myocardial infarction and in 28 with no evidence of it. Comparison of these routine delayed images with early views of the blood pool revealed two types of patterns. In patients with acute infarction, 95% had delayed images that were distinguishable from blood pool either because the activity was smaller than the early blood pool, or by the presence of localized activity superimposed on diffuse activity identical to blood pool. In those without infarction, 93% had activity distribution in routine delayed views matching that in the early blood-pool images. The usefulness of the diffuse TcPPi precordial activity in myocardial infarction is improved when early blood-pool imaging is used to exclude persistence of blood-pool activity as its cause. Moreover, it does not require additional amounts of radioactivity nor complex computer processing, a feature that may be of value in the community hospital using the technique to "rule out" infarction 24--72 hr after onset of suggestive symptoms.

  4. Combined technetium radioisotope penile plethysmography and xenon washout: A technique for evaluating corpora cavernosal inflow and outflow during early tumescence

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Schwartz, A.N.; Graham, M.M.

    1991-03-01

    Combined technetium radioisotope penile plethysmography and xenon washout is a new technique that measures both corporal arterial inflow and venous sinusoidal outflow during early tumescence in patients with erectile dysfunction. Fourteen patients were studied using 99mTc-RBCs to measure inflow and 133Xe or 127Xe in saline to measure outflow. Tumescence was induced by injecting papaverine intracorporally. Peak corporal rates corrected for inflow (r = 0.88) and uncorrected for outflow (r = 0.91) and change in volume over 2 min centered around peak inflow (r = 0.96) all correlated with angiography. Outflow measurements did not correlate with intracorporal resistance. Thus, outflow ratesmore » alone could not be used to predict venous sinusoidal competence. Normal inflow rate is greater than 20 ml/min; probable normal 12-20; indeterminate inflow 7-12; and abnormal inflow less than 7 ml/min. Technetium-99m radioisotope penile plethysmography and xenon washout can be performed together and both provide a method for simultaneously evaluating the relationship between corporal inflow and outflow rates in patients with erectile dysfunction.« less

  5. Radionuclide imaging of myocardial infarction using Tc-99m TBI

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holman, B.L.; Campbell, S.; Kirshenbaum, J.M.

    The cationic complex Tc-99m t-butylisonitrile (TBI) concentrates in the myocardial tissue of several animal species. Its myocardial distribution is proportional to blood flow both in zones of ischemia and in normal myocardium at rest. Planar, tomographic, and gated myocardial images have been obtained using Tc-99m TBI in the human. The authors investigated the potential application of Tc-99m TBI imaging to detect and localize myocardial infarction. Four subjects without clinical evidence of cardiovascular disease and five patients with ECG evidence of previous myocardial infarction were studied. Tc-99m TBI (10mCi) was injected intravenously with the patient in a resting state with planarmore » imaging in the anterior, 30 and 70 degree LAO projections beginning one hr after injection. The distribution of the tracer was homogeneous throughout the left ventricular wall in the normal subjects. Regional perfusion defects were present in 4/5 of the patients with myocardial infarction. Location of the defects corresponded to the location of the infarct using ECG criteria (2 inferoposterior and 2 anterior). The patient in whom the Tc-99m TBI image appeared normal had sustained a subendocardial myocardial infarct which could not be localized by ECG; the other 4 pts had transmural infarcts. Anterior and 30 degree LAO images were of excellent quality in all cases; there was overlap of the liver on the inferior wall of the left ventricle on the 70 degree LAO views. The authors conclude that accurate perfusion imaging may be possible using Tc-99m TBI in patients with transmural myocardial infarction.« less

  6. Technetium-99m(Sn2+)pyrophosphate in ischemic and infarcted dog myocardium in early stages of acute coronary occlusion: histochemical and tissue-counting comparisons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bianco, J.A.; Kemper, A.J.; Taylor, A.

    1983-06-01

    We have investigated the pattern of accumulation of Tc-99m(Sn2+)pyrophosphate (Tc-99m PPi) in myocardial tissue of dogs during the early stages of acute occlusion of the left anterior descending coronary artery. Three groups were studied after: (a) 40 min occlusion followed by 6 hr reperfusion (n . 6); (b) 6 hr occlusion followed by one hour reperfusion (n . 5); and (c) 7 hr occlusion with no reperfusion (n . 4). Areas of myocardial infarction were defined with triphenyl-tetrazolium chloride (TTC) staining, and blood flow was determined with 9-mu radioactive microspheres. In Group C uptake in infarcted and peri-infarct areas wasmore » not enhanced, most likely owing to low flow. In Group B, with late reperfusion, Tc-99m PPi sequestration was increased in both infarcted and peri-infarcted tissues. In Group A, areas ischemic during occlusion but with normal flow and viability by TTC after 6 hr of reperfusion showed significant uptake of Tc-99m PPi (twice the uptake of nonischemic regions).« less

  7. In vivo detection of small tumour lesions by multi-pinhole SPECT applying a 99mTc-labelled nanobody targeting the Epidermal Growth Factor Receptor

    PubMed Central

    Krüwel, Thomas; Nevoltris, Damien; Bode, Julia; Dullin, Christian; Baty, Daniel; Chames, Patrick; Alves, Frauke

    2016-01-01

    The detection of tumours in an early phase of tumour development in combination with the knowledge of expression of tumour markers such as epidermal growth factor receptor (EGFR) is an important prerequisite for clinical decisions. In this study we applied the anti-EGFR nanobody 99mTc-D10 for visualizing small tumour lesions with volumes below 100 mm3 by targeting EGFR in orthotopic human mammary MDA-MB-468 and MDA-MB-231 and subcutaneous human epidermoid A431 carcinoma mouse models. Use of nanobody 99mTc-D10 of a size as small as 15.5 kDa enables detection of tumours by single photon emission computed tomography (SPECT) imaging already 45 min post intravenous administration with high tumour uptake (>3% ID/g) in small MDA-MB-468 and A431 tumours, with tumour volumes of 52.5 mm3 ± 21.2 and 26.6 mm3 ± 16.7, respectively. Fast blood clearance with a serum half-life of 4.9 min resulted in high in vivo contrast and ex vivo tumour to blood and tissue ratios. In contrast, no accumulation of 99mTc-D10 in MDA-MB-231 tumours characterized by a very low expression of EGFR was observed. Here we present specific and high contrast in vivo visualization of small human tumours overexpressing EGFR by preclinical multi-pinhole SPECT shortly after administration of anti-EGFR nanobody 99mTc-D10. PMID:26912069

  8. Assessment of alveolar epithelial permeability in Behçet's disease with 99mTc-DTPA aerosol scintigraphy.

    PubMed

    Gumuser, Fikriye G; Pirildar, Timur; Batok, Dilek; Sakar, Aysin; Ruksen, Ebru; Sayit, Elvan

    2008-06-01

    Behçet's disease (BD) is a multisystem disorder characterized by vasculitis, and consists of a triad of recurrent ulcers of the oral and genital mucosa with relapsing uveitis. The prevalance of pulmonary involvement varies in the range of 1-10% in various studies and its complications are severe and life threatening. In this study, we investigated the changes of pulmonary epithelial permeability of patients with BD using technetium-99m diethylene triamine penta-acetic acid ((99m)Tc-DTPA) aerosol scintigraphy, so as to begin the therapy regimen as soon as possible. Twenty-one nonsmoking patients with BD (8 women, 13 men; mean age 38.67 +/- 8.86 years) and 15 healthy volunteer nonsmoking controls (8 women, 7 men; mean age 50.87 +/- 12.45 years) underwent (99m)Tc-DTPA aerosol inhalation scintigraphy and pulmonary function tests (PFTs). Subjects inhaled 1480 MBq of (99m)Tc-DTPA for 4 min in the supine position. Scintigraphic data were recorded dynamically (1 frame/min) in the posterior projection on a 64 x 64 matrix for a 30-min period using a double-headed gamma camera (Infinia, GE, Tirat Hacarmel, Israel) equipped with a low-energy all-purpose parallel hole collimator. Half time of (99m)Tc-DTPA clearance (T (1/2)) was calculated by placing a mono-exponential fit on the curves. Penetration index (PI) was also calculated by dividing the peripheral total counts by the sum of the peripheral and central total counts on the first minute image, in order to quantify the distribution of the inhaled aerosol. The clearance half time of (99m)Tc-DTPA radioaerosols in the BD patients (24.81 +/- 6.22 min) was faster than in the normal control group (46.53 +/- 22.41 min) (P = 0.004). There was also a significant difference between PI of the patients with BD (0.15 +/- 0.03) and that of the controls (0.21 +/- 0.06) (P = 0.002). No correlation was found between the mean T (1/2) values of (99m)Tc-DTPA clearance or the spirometric measurements in the BD patients. Penetration indices

  9. Technetium-99 cycling in maple trees: characterization of changes in chemical form.

    PubMed

    Garten, C T; Lomax, R D

    1989-08-01

    Prior field studies near an old radioactive waste disposal site at Oak Ridge, TN, indicated that following root uptake, metabolism by deciduous trees rendered 99Tc less biogeochemically mobile than expected, based on chemistry of the pertechnetate (TcO-4) anion. Subsequently, the form of technetium (Tc) in maple tree (Acer sp.) sap, leaves, wood and forest leaf litter was characterized using one or more of the following methods: dialysis, physical fractionation, chemical extraction, gel permeation chromatography, enzymatic extraction, or thin layer chromatography (TLC) on silica gel. Chromatography (Sephadex G-25) of TcO-4 incubated in vitro with tree sap showed it to behave similar to TcO-4 anion. When labeled wood and leaf tissues were processed using a tissue homogenizer, 15% and 40%, respectively, of the Tc was solubilized into phosphate buffer. Most (65% to 80%) of the solubilized Tc passing a 0.45-micron filter also passed through an ultrafiltration membrane with a nominal molecular weight cutoff of 10,000 atomic mass units (amu). A majority (72% to 80%) of the Tc in wood could be chemically removed by successive extractions with ethanol, water and weak mineral acid. These same extractants removed only 23% to 31% of the Tc from maple leaves or forest floor leaf litter. Most of the Tc in leaves and leaf litter was removed only by strongly alkaline reagents typically used to release structural polysaccharides (hemicelluloses) from plant tissues. Chromatography (Sephadex G-25) of the ethanol-water extract from wood and the alkaline extract from leaves demonstrated that Tc in these extracts was not principally TcO-4 but was complexed with molecules greater than 1000 amu. Incubations of leaf and wood homogenates with protease approximately doubled the amount of Tc released from contaminated tissues. Ultrafiltration of protease-solubilized Tc from leaves and wood showed that 40% and 93%, respectively, of the Tc was less than 10,000 amu. TLC of the less than 10

  10. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Technetium-97m 100 Technetium-97 100 Technetium-99m 100 Technetium-99 10 Tellurium-125m 10 Tellurium-127m 10 Tellurium-127 100 Tellurium-129m 10 Tellurium-129 100 Tellurium-131m 10 Tellurium-132 10...

  11. 10 CFR Appendix B to Part 30 - Quantities 1 of Licensed Material Requiring Labeling

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Technetium-97m 100 Technetium-97 100 Technetium-99m 100 Technetium-99 10 Tellurium-125m 10 Tellurium-127m 10 Tellurium-127 100 Tellurium-129m 10 Tellurium-129 100 Tellurium-131m 10 Tellurium-132 10...

  12. The use of {sup 99m}Tc-Al{sub 2}O{sub 3} for detection of sentinel lymph nodes in breast cancer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sinilkin, I., E-mail: sinilkinig@oncology.tomsk.ru; Chernov, V.; Medvedeva, A.

    2016-08-02

    Purpose: to study the feasibility of using the new radiopharmaceutical based on the technetium-99m-labeled gamma-alumina for identification of sentinel lymph nodes (SLNs) in breast cancer patients. The study included two groups of breast cancer patients who underwent single photon emission computed tomography (SPECT) and intraoperaive gamma probe identification of sentinel lymph nodes (SLNs). To identify SLNs, the day before surgery Group I patients (n = 34) were injected with radioactive {sup 99m}Tc-Al{sub 2}O{sub 3}, and Group II patients (n = 30) received {sup 99m}Tc-labeled phytate colloid. A total of 37 SLNs were detected in Group I patients. The number ofmore » identified SLNs per patient ranged from 1 to 2 (the average number of identified SLNs was 1.08). Axillary lymph nodes were the most common site of SLN localization. 18 hours after {sup 99m}Tc-Al{sub 2}O{sub 3} injection, the percentage of its accumulation in the SLN was 7–11% (of the counts in the injection site) by SPECT and 17–31% by gamma probe detection. In Group II SLNs were detected in 27 patients. 18 hours after injection of the phytate colloid the percentage of its accumulation in the SLN was 1.5–2% out of the counts in the injection site by SPECT and 4–7% by gamma probe. The new radiopharmaceutical based on the {sup 99m}Tc-Al{sub 2}O{sub 3} demonstrates high accumulation in SLNs without redistribution through the entire lymphatic basin. The sensitivity and specificity of {sup 99m}Tc-Al{sub 2}O{sub 3} were 100% for both SPECT and intraoperative gamma probe identification.« less

  13. A strategy for intensive production of molybdenum-99 isotopes for nuclear medicine using CANDU reactors.

    PubMed

    Morreale, A C; Novog, D R; Luxat, J C

    2012-01-01

    Technetium-99m is an important medical isotope utilized worldwide in nuclear medicine and is produced from the decay of its parent isotope, molybdenum-99. The online fueling capability and compact fuel of the CANDU(®)(1) reactor allows for the potential production of large quantities of (99)Mo. This paper proposes (99)Mo production strategies using modified target fuel bundles loaded into CANDU fuel channels. Using a small group of channels a yield of 89-113% of the weekly world demand for (99)Mo can be obtained. Copyright © 2011 Elsevier Ltd. All rights reserved.

  14. Intraoperative sentinel node identification in early stage cervical cancer using a combination of radiolabeled albumin injection and isosulfan blue dye injection.

    PubMed

    Martínez-Palones, José M; Gil-Moreno, Antonio; Pérez-Benavente, María A; Roca, Isabel; Xercavins, Jordi

    2004-03-01

    We investigated the feasibility of sentinel lymph node identification using radioisotopic lymphatic mapping with technetium-99m-labeled human serum albumin and isosulfan blue dye injection in patients undergoing radical hysterectomy with pelvic lymphadenectomy for treatment of early cervical cancer. Between September 2000 and October 2002, 25 patients with cervical cancer FIGO stage I (n=24) or stage II (n=1) underwent sentinel lymph node detection with preoperative lymphoscintigraphy (technetium-99m colloid albumin injection around the tumor) and intraoperative lymphatic mapping with blue dye and a handheld or laparoscopic gamma probe. Complete pelvic or paraaortic lymphadenectomy was performed in all cases by open surgery or laparoscopic surgery. In 23 evaluable patients, a total of 51 sentinel lymph nodes were detected by lymphoscintigraphy (mean 2.21 nodes per patient). Intraoperatively, 61 sentinel lymph nodes were identified, with a mean of 2.52 nodes per patient by gamma probe and a mean of 1.94 nodes per patient after isosulfan blue injection. Forty percent of sentinel nodes were found in the interiliac region and 25% in the external iliac area. Microscopic nodal metastases (four nodes) were confirmed in 12% of cases. All these lymph nodes were previously detected as sentinel lymph nodes. The remaining 419 nodes after pelvic lymphadenectomy were histologically negative. Sentinel lymph node identification with technetium-99m-labeled nanocolloid combined with blue dye injection is feasible and showed a 100% negative predictive value, and potentially identified women in whom lymph node dissection can be avoided.

  15. 18F-Fluorocholine PET/CT in the assessment of primary hyperparathyroidism compared with 99mTc-MIBI or 99mTc-tetrofosmin SPECT/CT: a prospective dual-centre study in 100 patients.

    PubMed

    Beheshti, Mohsen; Hehenwarter, Lukas; Paymani, Zeinab; Rendl, Gundula; Imamovic, Larisa; Rettenbacher, Rupert; Tsybrovskyy, Oleksiy; Langsteger, Werner; Pirich, Christian

    2018-03-08

    In this prospective study we compared the accuracy of 18 F-fluorocholine PET/CT with that of 99m Tc-MIBI or 99m Tc-tetrofosmin SPECT/CT in the preoperative detection of parathyroid adenoma in patients with primary hyperparathyroidism. We also assessed the value of semiquantitative parameters in differentiating between parathyroid hyperplasia and adenoma. Both 18 F-fluorocholine PET/CT and 99m Tc-MIBI/tetrofosmin SPECT/CT were performed in 100 consecutive patients with biochemical evidence of primary hyperparathyroidism. At least one abnormal focus on either 18 F-fluorocholine or 99m Tc-MIBI/tetrofosmin corresponding to a parathyroid gland or ectopic parathyroid tissue was considered as a positive finding. In 76 patients with positive findings on at least one imaging modality, surgical exploration was performed within 6 months, and the results were related to histopathological findings and clinical and laboratory findings at 3-6 months as the standard of truth. In 24 patients, no surgery was performed: in 18 patients with positive imaging findings surgery was refused or considered risky, and in 6 patients imaging was negative. Therefore, data from 82 patients (76 undergoing surgery, 6 without surgery) in whom the standard of truth criteria were met, were used in the final analysis. All patients showed biochemical evidence of primary hyperparathyroidism with a mean serum calcium level of 2.78 ± 0.34 mmol/l and parathormone (PTH) level of 196.5 ± 236.4 pg/ml. The study results in 76 patients with verified histopathology and 3 patients with negative imaging findings were analysed. Three of six patients with negative imaging showed normalized serum PTH and calcium levels on laboratory follow-up at 3 and 6 months, and the results were considered true negative. In a patient-based analysis, the detection rate with 18 F-fluorocholine PET/CT was 93% (76/82), but was only 61% (50/82) with 99m Tc-MIBI/tetrofosmin SPECT/CT. In a lesion-based analysis, the

  16. Imaging prostate cancer (PCa) with [99m Tc(CO)3 ]finasteride dithiocarbamate.

    PubMed

    Shah, Syed Qaiser; Gul-E-Raana; Uddin, Ghias

    2018-06-15

    This investigation aimed to modify finasteride (1) to finasteride dithiocarbamate (2) for subsequent synthesis of the rhenium analogue (3) and [ 99m Tc]tricarbonyl complexes (4), to assess its prostate cancer (PCa) targeting potential in a rat model. To validate the identity of (4), reference (3) has been synthesized by using fac-[Net 4 ] 2 [ReBr 3 (CO) 3 ] precursor and characterized by 1 H-NMR, 13 C-NMR, ESI-MS, and elemental analysis. The analogue (4) was synthesized by using fac-[ 99m Tc(H 2 O) 3 (CO) 3 ] + precursor, and its structure was confirmed by comparative HPLC by using (3) as a reference. Further, the suitability of (4) as a PCa imaging agent was investigated in vitro and in vivo. At room temperature, (4) had ≥99% radiochemical purity and remained ≥84% stable in serum. In preclinical studies, biodistribution of (4) in histopathologically established rat model showed adequately high in vivo uptake in the prostate attracting the possibility of using it for noninvasive imaging of PCa. Copyright © 2018 John Wiley & Sons, Ltd.

  17. PLA-PEG nanocapsules radiolabeled with 99mTechnetium-HMPAO: release properties and physicochemical characterization by atomic force microscopy and photon correlation spectroscopy.

    PubMed

    Pereira, Maira Alves; Mosqueira, Vanessa Carla Furtado; Vilela, José Mário Carneiro; Andrade, Margareth Spangler; Ramaldes, Gilson Andrade; Cardoso, Valbert Nascimento

    2008-01-01

    The present work describes the preparation, characterization and labelling of conventional and surface-modified nanocapsules (NC) with 99m Tc-HMPAO. The size, size distribution and homogeneity were determined by photon correlation spectroscopy (PCS) and zeta potential by laser doppler anemometry. The morphology and the structural organization were evaluated by atomic force microscopy (AFM). The stability and release profile of the NC were determined in vitro in plasma. The results showed that the use of methylene blue induces significant increase in the encapsulation efficiency of 99m Tc-HMPAO, from 24.4 to 49.8% in PLA NC and 22.37 to 52.93% in the case of PLA-PEG NC (P<0.05) by improving the complex stabilization. The average diameter of NC calculated by PCS varied from 216 to 323 nm, while the average diameter determined by AFM varied from 238 to 426 nm. The AFM analysis of diameter/height ratios suggested a greater homogeneity of the surface-modified PLA-PEG nanocapsules compared to PLA NC concerning their flattening properties. The in vitro release of the 99m Tc-HMPAO in plasma medium was faster for the conventional PLA NC than for the surface-modified NC. For the latter, 60% of the radioactivity remained associated with NC, even after 12h of incubation. The results suggest that the surface-modified 99m Tc-HMPAO-PLA-PEG NC was more stable against label leakage in the presence of proteins and could present better performance as radiotracer in vivo.

  18. Diagnostic value of (99m)Tc-3PRGD2 scintimammography for differentiation of malignant from benign breast lesions: Comparison of visual and semi-quantitative analysis.

    PubMed

    Chen, Qianqian; Xie, Qian; Zhao, Min; Chen, Bin; Gao, Shi; Zhang, Haishan; Xing, Hua; Ma, Qingjie

    2015-01-01

    To compare the diagnostic value of visual and semi-quantitative analysis of technetium-99m-poly-ethylene glycol, 4-arginine-glycine-aspartic acid ((99m)Tc-3PRGD2) scintimammography (SMG) for better differentiation of benign from malignant breast masses, and also investigate the incremental role of semi-quantitative index of SMG. A total of 72 patients with breast lesions were included in the study. Technetium-99m-3PRGD2 SMG was performed with single photon emission computed tomography (SPET) at 60 min after intravenous injection of 749 ± 86MBq of the radiotracer. Images were evaluated by visual interpretation and semi-quantitative indices of tumor to non-tumor (T/N) ratios, which were compared with pathology results. Receiver operating characteristics (ROC) curve analyses were performed to determine the optimal visual grade, to calculate cut-off values of semi-quantitative indices, and to compare visual and semi-quantitative diagnostic values. Among the 72 patients, 89 lesions were confirmed by histopathology after fine needle aspiration biopsy or surgery, 48 malignant and 41 benign lesions. The mean T/N ratio of (99m)Tc-3PRGD2 SMG in malignant lesions was significantly higher than that in benign lesions (P<0.05). When grade 2 of the disease was used as cut-off value for the detection of primary breast cancer, the sensitivity, specificity and accuracy were 81.3%, 70.7%, and 76.4%, respectively. When a T/N ratio of 2.01 was used as cut-off value, the sensitivity, specificity and accuracy were 79.2%, 75.6%, and 77.5%, respectively. According to ROC analysis, the area under the curve for semi-quantitative analysis was higher than that for visual analysis, but the statistical difference was not significant (P=0.372). Compared with visual analysis or semi-quantitative analysis alone, the sensitivity, specificity and accuracy of visual analysis combined with semi-quantitative analysis in diagnosing primary breast cancer were higher, being: 87.5%, 82.9%, and 85

  19. Ion Exchange Column Tests Supporting Technetium Removal Resin Maturation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, C.; McCabe, D.; Hamm, L.

    2013-12-20

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant, currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and sealed in canisters. The LAW glass will be disposed on site. There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Due to the soluble properties of pertechnetate and long half-life ofmore » 99Tc, effective management of 99Tc is important. Options are being explored to immobilize the supplemental LAW portion of the tank waste, as well as to examine the volatility of 99Tc during the vitrification process. Removal of 99Tc, followed by off-site disposal has potential to reduce treatment and disposal costs. A conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. SuperLig® 639 is an elutable ion exchange resin. In the tank waste, 99Tc is predominantly found in the tank supernate as pertechnetate (TcO 4 -). Perrhenate (ReO 4 -) has been shown to be a good non-radioactive surrogate for pertechnetate in laboratory testing for this ion exchange resin. This report contains results of experimental ion exchange distribution coefficient and column resin maturation kinetics testing using the resin SuperLig® 639a to selectively remove perrhenate from simulated LAW. This revision includes results from testing to determine effective resin operating temperature range. Loading tests were performed at 45°C, and the computer modeling was updated to include the temperature effects. Equilibrium contact testing indicated that this batch of SuperLig® 639 resin has good performance, with an average perrhenate distribution coefficient of

  20. Preparation of 99mTc-TRODAT-1 with high labeling yield in boiling water bath: a new formulation.

    PubMed

    Erfani, Mostafa; Shafiei, Mohammad

    2014-04-01

    A new formulation for preparation of (99m)Tc-labeled tropane derivative, (99m)Tc-TRODAT-1, which is useful as a potential CNS dopamine transporter imaging agent, was evaluated and characterized. Preparation of (99m)Tc-TRODAT-1 was attained previously by a formulation in which vial has to be autoclaved at 121 °C for 30 min. It is highly desirable to further improve the preparation method by developing a simplified one vial formulation which will be labeled in boiling water bath (95 °C) for 15 min and a high labeling yield will be achieved. A formulation contained 10 μg of TRODAT-1, 20 μg tricine, 40 μg SnCl2 and 20mg manitol was prepared. Labeling was performed at 95 °C for 15 min and radiochemical analysis involved ITLC and HPLC methods. The stability of radioconjugate was checked in the presence of human serum at 37 °C up to 24h. (99m)Tc-TRODAT-1 was prepared with a radiochemical purity of more than 95% and specific activity of 64.3 MBq/nmol. Biodistribution studies of this new formulation in rats revealed similar regional brain distribution as compared with those obtained with the previous preparation in which brain uptake was high in striatum and striatum to cerebellum ratio was high. Requiring no autoclave facility for labeling, this new formulation will significantly improve the using feasibility of this radiopharmaceutical in clinic. Copyright © 2014 Elsevier Inc. All rights reserved.

  1. Technetium-99m HMPAO brain SPECT in autistic children and their families.

    PubMed

    Degirmenci, Berna; Miral, Süha; Kaya, Gamze Capa; Iyilikçi, Leyla; Arslan, Gulhan; Baykara, Ayşen; Evren, Ismail; Durak, Hatice

    2008-04-15

    The purpose of the study was to investigate perfusion patterns in autistic children (AC) and their families. Ten AC (9 boys, 1 girl; mean age: 6.9+/-1.7 years) with autistic disorder defined by DSM-III-R criteria, five age-matched children (3 boys, 2 girls) as a control group, and the immediate family members of eight AC (8 mothers, 8 fathers, 7 siblings; mean ages: 39+/-4 years, 36+/-5 years and 13+/-5 years, respectively) were included in the study. Age- and sex-matched control groups for both the parents and the siblings were also included in the study. Brain perfusion images were obtained 1 h after the intravenous injection of an adjusted dose of Tc-99m HMPAO to children and the adults. Visual and semiquantitative evaluations were performed. Hypoperfusion was seen in the right posterior parietal cortex in three AC, in bilateral parietal cortex in one AC, bilateral frontal cortex in two AC, left parietal and temporal cortex in one AC, and right parietal and temporal cortex in one AC. Asymmetric perfusion was observed in the caudate nucleus in four AC. In semiquantitative analyses, statistically significant hypoperfusion was found in the right inferior and superior frontal, left superior frontal, right parietal, right mesial temporal and right caudate nucleus. In parents of AC, significant hypoperfusion was noted in the right parietal and bilateral inferior frontal cortex. In siblings of AC, perfusion in the right frontal cortex, right nucleus caudate and left parietal cortex was significantly decreased. This preliminary study suggests the existence of regional brain perfusion alterations in frontal, temporal, and parietal cortex and in caudate nucleus in AC and in their first-degree family members.

  2. 99mTc-tagged chicken liver as a marker of solid food in the human stomach.

    PubMed

    Meyer, J H; MacGregor, I L; Gueller, R; Martin, P; Cavalieri, R

    1976-04-01

    Past measurement of gastric emptying of solid food in man has depended on external counting of surface-absorbed isotopes without verification that isotopic labels remain attached to solid food in the stomach. In this study chicken liver was isotopically labeled with 99mTc incorporated uniformly and intracellularly throughout the liver substance. In vitro studies showed less than 10% loss of 99mTc from liver incubated with pepsin HC1. By contrast, up to 90% of 51Cr absorbed to scrambled eggs became detached under similar conditions. In feeding experiments less than 10% of 99mTc was liberated from fed 99mTc liver, while significantly more 51Cr became detached from egg under identical intragastric conditions. We conclude that 99mTc-tagged chicken liver is an adequate marker of the rate of emptying of solid food and appears to be more reliable than 51Cr-labeled scrambled eggs from which 51Cr dissociates in the stomach.

  3. 99mTc Labeled Glucagon-Like Peptide-1-Analogue (99mTc-GLP1) Scintigraphy in the Management of Patients with Occult Insulinoma

    PubMed Central

    Sowa-Staszczak, Anna; Trofimiuk-Müldner, Małgorzata; Stefańska, Agnieszka; Tomaszuk, Monika; Buziak-Bereza, Monika; Gilis-Januszewska, Aleksandra; Jabrocka-Hybel, Agata; Głowa, Bogusław; Małecki, Maciej; Bednarczuk, Tomasz; Kamiński, Grzegorz; Kowalska, Aldona; Mikołajczak, Renata; Janota, Barbara; Hubalewska-Dydejczyk, Alicja

    2016-01-01

    Introduction The aim of this study was to assess the utility of [Lys40(Ahx-HYNIC-99mTc/EDDA)NH2]-exendin-4 scintigraphy in the management of patients with hypoglycemia, particularly in the detection of occult insulinoma. Materials and Methods Forty patients with hypoglycemia and increased/confusing results of serum insulin and C-peptide concentration and negative/inconclusive results of other imaging examinations were enrolled in the study. In all patients GLP-1 receptor imaging was performed to localise potential pancreatic lesions. Results Positive results of GLP-1 scintigraphy were observed in 28 patients. In 18 patients postsurgical histopathological examination confirmed diagnosis of insulinoma. Two patients had contraindications to the surgery, one patient did not want to be operated. One patient, who presented with postprandial hypoglycemia, with positive result of GLP-1 imaging was not qualified for surgery and is in the observational group. Eight patients were lost for follow up, among them 6 patients with positive GLP-1 scintigraphy result. One patient with negative scintigraphy was diagnosed with malignant insulinoma. In two patients with negative scintigraphy Munchausen syndrome was diagnosed (patients were taking insulin). Other seven patients with negative results of 99mTcGLP-1 scintigraphy and postprandial hypoglycemia with C-peptide and insulin levels within the limits of normal ranges are in the observational group. We would like to mention that 99mTc-GLP1-SPECT/CT was also performed in 3 pts with nesidioblastosis (revealing diffuse tracer uptake in two and a focal lesion in one case) and in two patients with malignant insulinoma (with the a focal uptake in the localization of a removed pancreatic headin one case and negative GLP-1 1 scintigraphy in the other patient). Conclusions 99mTc-GLP1-SPECT/CT could be helpful examination in the management of patients with hypoglycemia enabling proper localization of the pancreatic lesion and effective

  4. Non-Q-wave myocardial infarction: impaired myocardial energy metabolism in regions with reduced 99mTc-MIBI accumulation.

    PubMed

    Moka, D; Baer, F M; Theissen, P; Schneider, C A; Dietlein, M; Erdmann, E; Schicha, H

    2001-05-01

    Reduced regional technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) accumulation in patients with chronic non-Q-wave infarction (NQWI) but without significant coronary artery stenosis indicates non-transmural damage of the myocardial wall. The aim of this study was to characterise cardiac energy metabolism after NQWI using phosphorus-31 magnetic resonance spectroscopy (31P-MRS) and to compare the biochemical remodelling with changes in regional 99mTc-MIBI uptake and with morphological and functional parameters assessed by magnetic resonance imaging (MRI). Fifteen patients with a history of NQWI, exclusion of significant coronary artery stenosis (<50% diameter stenosis) and hypokinesia of the anterior wall (group A) were examined with 31P-MRS to study the effects of NQWI on myocardial energy metabolism. Spectroscopic measurements were performed in the infarct-related myocardial region. Corresponding gradient-echo MR images and myocardial 99mTc-MIBI single-photon emission tomography images were acquired for exact localisation of the infarct region. All examinations were performed at rest under anti-ischaemic medication. Data were compared with those of patients in whom coronary artery disease had been excluded by angiography (group B, n=10). All patients of group A displayed anterior wall hypokinesia in the infarcted area on both ventriculography and MRI, with a reduced myocardial accumulation of 99mTc-MIBI (66.3%+/-11.8% vs 95.6%+/-2.2% in group B). The mean wall thickness during the complete cardiac cycle (9.5+/-1.8 mm vs 13.1+/-1.1 mm in group B, P<0.001), the systolic wall thickening (2.6+/-1.4 mm vs 5.8+/-1.5 mm in group B, P<0.01) and the phosphocreatine/adenosine triphosphate ratio (1.12+/-0.22 vs 1.74+/-0.23 in group B, P<0.01) in the hypokinetic area were all significantly reduced. It is concluded that persisting hypokinetic myocardium after NQWI combined with reduced myocellular uptake of 99mTc-MIBI displays a reduced PCr/ATP ratio. Our results indicate

  5. Clinical usefulness of 99mTc-EDDA/HYNIC-TOC scintigraphy in oncological diagnostics: a preliminary communication.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Maecke, Helmut R; Młodkowska, Ewa; Kunert-Radek, Jolanta; Michalski, Andrzej; Rzeszutek, Katarzyna; Kozak, Józef; Kuśmierek, Jacek

    2003-10-01

    This study assessed the clinical usefulness of a new technetium-99m labelled somatostatin analogue from the standpoint of oncological diagnostics. The study group comprised 40 patients in whom malignant neoplasms (32 primary and 8 metastatic) had been diagnosed. Among the primary tumours there were 21 cases of lung cancer (2 small cell and 19 non-small cell), seven pituitary adenomas (five hormonally active and two inactive), one liposarcoma, two carcinoids and one breast carcinoma. The metastatic tumours consisted of three malignant melanomas, one phaeochromocytoma, one prostatic cancer, one leiomyosarcoma, one pancreatic carcinoma ectopically secreting ACTH and one carcinoid of the thymus. The radiopharmaceutical 99mTc-EDDA/HYNIC-Tyr3-octreotide was administered i.v. at an activity of 740-925 MBq. The imaging comprised a whole-body scan and a single-photon emission tomography acquisition. Positive scintigrams were obtained in all cases of small cell and non-small cell lung cancer, four out of five hormonally active pituitary adenomas, one out of two cases of carcinoid, the liposarcoma and the breast cancer. Neoplastic metastases were visualised in two out of three patients with melanoma and in patients with phaeochromocytoma, ACTH-secreting pancreatic carcinoma and thymic carcinoid. Scintigrams were negative in both hormonally inactive pituitary adenomas, in one case of metastatic malignant melanoma, in the leiomyosarcoma and in the case of metastasis from prostatic carcinoma. The results of this pilot study indicate that 99mTc-EDDA/HYNIC-TOC is a potentially useful radiopharmaceutical for imaging of a wide range of primary and metastatic tumours. Special attention should be paid to the successful imaging of all cases of non-small cell lung cancer.

  6. Discordant hepatic uptake between Tc-99m sulfur colloid and Tc-99m DISIDA in hypervitaminosis A

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vincent, L.M.; McCartney, W.H.; Mauro, M.A.

    1984-02-01

    Scintigraphic findings in a patient with biopsy-proven hypervitaminosis A included markedly impaired hepatic uptake of Tc-99m sulfur colloid but essentially normal uptake of Tc-99m DISIDA. This case presents a potential cause for image discordance with these two agents.

  7. New Gastrin Releasing Peptide Receptor-Directed [99mTc]Demobesin 1 Mimics: Synthesis and Comparative Evaluation.

    PubMed

    Nock, Berthold A; Charalambidis, David; Sallegger, Werner; Waser, Beatrice; Mansi, Rosalba; Nicolas, Guillaume P; Ketani, Eleni; Nikolopoulou, Anastasia; Fani, Melpomeni; Reubi, Jean-Claude; Maina, Theodosia

    2018-04-12

    We have previously reported on the gastrin releasing peptide receptor (GRPR) antagonist [ 99m Tc]1, ([ 99m Tc]demobesin 1, 99m Tc-[N 4 '-diglycolate-dPhe 6 ,Leu-NHEt 13 ]BBN(6-13)). [ 99m Tc]1 has shown superior biological profile compared to analogous agonist-based 99m Tc-radioligands. We herein present a small library of [ 99m Tc]1 mimics generated after structural modifications in (a) the linker ([ 99m Tc]2, [ 99m Tc]3, [ 99m Tc]4), (b) the peptide chain ([ 99m Tc]5, [ 99m Tc]6), and (c) the C-terminus ([ 99m Tc]7 or [ 99m Tc]8). The effects of above modifications on the biological properties of analogs were studied in PC-3 cells and tumor-bearing SCID mice. All analogs showed subnanomolar affinity for the human GRPR, while most receptor-affine 4 and 8 behaved as potent GRPR antagonists in a functional internalization assay. In mice bearing PC-3 tumors, [ 99m Tc]1-[ 99m Tc]6 exhibited GRPR-specific tumor uptake, rapidly clearing from normal tissues. [ 99m Tc]4 displayed the highest tumor uptake (28.8 ± 4.1%ID/g at 1 h pi), which remained high even after 24 h pi (16.3 ± 1.8%ID/g), well surpassing that of [ 99m Tc]1 (5.4 ± 0.7%ID/g at 24 h pi).

  8. Sjögren's syndrome associated with protein losing gastroenteropathy manifested by intestinal lymphangiectasia successfully treated with prednisolone and hydroxychloroquine.

    PubMed

    Liao, C-Y; Chien, S-T; Wang, C-C; Chen, I-H; Chiu, H-W; Liu, M-Y; Lin, C-H; Ben, R-J; Tsai, M-K

    2015-12-01

    Protein-losing gastroenteropathy (PLGE), a rare manifestation of primary Sjögren's syndrome (SS), is characterized by profound edema and severe hypoalbuminemia secondary to excessive serum protein loss from the gastrointestinal tract and is clinically indistinguishable from nephrotic syndrome. We report a case of a 30-year-old Taiwanese woman with PLGE-associated SS. In addition to a positive Schirmer's test, she had eye-dryness, thirst, and high levels of anti-SSA antibodies, fulfilling SS criteria. PLGE diagnosis was highly appropriate given the clinical profile of hypoalbuminemia, hypercholesterolemia, pleural effusion, and ascites, with absent cardiac, hepatic, or renal disease. We were unable to perform technetium-99m-labeled human serum albumin scintigraphy ((99m)Tc-HAS). However, the patient's edema and albumin level improved dramatically in response to a 3-month regime of oral prednisolone followed by oral hydroxychloroquine. © The Author(s) 2015.

  9. 99 mTc-MIBI washout as a complementary factor in the evaluation of idiopathic dilated cardiomyopathy (IDCM) using myocardial perfusion imaging.

    PubMed

    Shiroodi, Mohammad Kazem; Shafiei, Babak; Baharfard, Nastaran; Gheidari, Mohammad Esmail; Nazari, Babak; Pirayesh, Elaheh; Kiasat, Ali; Hoseinzadeh, Samaneh; Hashemi, Abolghassem; Akbarzadeh, Mohammad Ali; Javadi, Hamid; Nabipour, Iraj; Assadi, Majid

    2012-01-01

    Rapid technetium-99 m methoxyisobutylisonitrile (99 mTc-MIBI) washout has been shown to occur in impaired myocardia. This study is based on the hypothesis that scintigraphy can be applied to calculate the myocardial 99 mTc-MIBI washout rate (WR) to diagnose and evaluate heart failure severity and other left ventricular functional parameters specifically in idiopathic dilated cardiomyopathy (IDCM) patients. Patients with IDCMP (n = 17; 52.65 ± 11.47 years) and normal subjects (n = 6; 49.67 ± 10.15 years) were intravenously administered 99 mTc-hexakis-2-methoxyisobutylisonitrile (99 mTc-MIBI). Next, early and delayed planar data were acquired (at 3.5-h intervals), and electrocardiogram (ECG)-gated myocardial perfusion single photon emission computed tomography (SPECT) was performed. The 99 mTc-MIBI WR was calculated using early and delayed planar images. Left ventricular functional parameters were also analyzed using quantitative gated SPECT (QGS) data. In target group, myocardial WRs (29.13 ± 6.68%) were significantly higher than those of control subjects (14.17 ± 3.31%; P < 0.001). The 99 mTc-MIBI WR increased with the increasing severity of the NYHA functional class (23.16 ± 1.72% for class I, 30.25 ± 0.95% for class II, 32.60 ± 6.73% for class III, and 37.50 ± 7.77% for class IV; P = 0.02). The WR was positively correlated with the end-diastolic volume (EDV) index (r (2) = 0.216; β = 0.464; P = 0.02 [ml/m(2)], the end-systolic volume (ESV) index (r (2) = 0.234; β = 0.484; P = 0.01 [ml/m(2)]), the summed motion score (SMS) (r (2) = 0.544; β = 0.738; P = 0.00), and the summed thickening score (STS) (r (2) = 0.656; β = 0.810; P = 0.00); it was negatively correlated with the left ventricular ejection fraction (LVEF) (r (2) = 0.679; β = -0.824; P = 0.00). It can be concluded that 99 mTc-MIBI scintigraphy might be a valuable molecular imaging tool for the diagnosis and evaluation of myocardial damage or dysfunction severity.

  10. 99mTc-EDDA/HYNIC-TOC and (18)F-FDG in thyroid cancer patients with negative (131)I whole-body scans.

    PubMed

    Gabriel, Michael; Froehlich, Franz; Decristoforo, Clemens; Ensinger, Christian; Donnemiller, Eveline; von Guggenberg, Elisabeth; Heute, Dirk; Moncayo, Roy

    2004-03-01

    Several studies have reported on the expression of somatostatin receptors in patients with differentiated thyroid cancer (DTC). The aim of this study was to evaluate the imaging abilities of a recently developed technetium-99m labelled somatostatin analogue, (99m)Tc-EDDA/HYNIC-TOC ((99m)Tc-TOC), in terms of precise localisation of disease. The study population comprised 54 patients (24 men, 30 women; age range 22-90 years) with histologically confirmed DTC who presented with recurrent or persistent disease as indicated by elevated Tg levels after initial treatment. All patients were negative on the iodine-131 post-therapy whole-body scans. Fluorine-18 fluorodeoxyglucose positron emission tomography ((18)F-FDG PET) was performed in a subgroup of 36 patients. The study population consisted of two groups: Group A ( n=22) comprised patients with disease recurrence as shown by elevated Tg levels but without detectable pathology. In group B ( n=32), pre-existing lesions were known. Among the 54 cases, SSTR scintigraphy was true positive in 33 (61.1%), true negative in 4 (7.4%) and false negative in 17 (31.5%) cases, which resulted in a sensitivity of 66%. A total of 138 tumour foci were localised in 33 patients. The fraction of true positive (99m)Tc-TOC findings was positively correlated ( P<0.01) with elevated Tg levels (higher than 30 ng/ml). Despite two false positive findings, analysis on a lesion basis demonstrated better diagnostic efficacy with (18)F-FDG PET ( P<0.001); however, it also revealed substantial agreement between the imaging techniques [Cohen's kappa of 0.62 (0.47-0.78)]. In conclusion, scintigraphy with (99m)Tc-TOC might be a promising tool for treatment planning; it is easy to perform and showed sufficient accuracy for localisation diagnostics in thyroid cancer patients with recurrent or metastatic disease.

  11. Measurement of tamsulosin in human serum by liquid chromatography–tandem mass spectrometry☆

    PubMed Central

    Upreti, Rita; Homer, Natalie Z.M.; Naredo, Gregorio; Cobice, Diego F.; Hughes, Katherine A.; Stewart, Laurence H.; Walker, Brian R.; Andrew, Ruth

    2013-01-01

    A simple, sensitive and robust method to extract tamsulosin from human serum, and quantify by liquid chromatography–tandem mass spectrometry (LC–MS/MS) was developed and validated and is applicable as a measure of compliance in clinical research. Tamsulosin was extracted from human serum (100 μL) via liquid–liquid extraction with methyl tert-butyl ether (2 mL) following dilution with 0.1 M ammonium hydroxide (100 μL), achieving 99.9% analyte recovery. Internal standard, d9-finasteride, was synthesised in-house. Analyte and internal standard were separated on an Ascentis® Express C18 (100 mm × 3 mm, 2.7 μm) column using a gradient elution with mobile phases methanol and 2 mM aqueous ammonium acetate (5:95, v/v). Total run-time was 6 min. Tamsulosin was quantified using a triple quadrupole mass spectrometer operated in multi-reaction-monitoring (MRM) mode using positive electrospray ionisation. Mass transitions monitored for quantitation were: tamsulosin m/z 409 → 228 and d9-finasteride m/z 382 → 318, with the structural formulae of ions confirmed by Fourier transform ion cyclotron resonance mass spectrometry (within 10 ppm). The limit of quantitation was 0.2 ng/mL, and the method was validated in the linear range 0.2–50 ng/mL with acceptable inter- and intra-assay precision and accuracy and stability suitable for routine laboratory practice. The method was successfully applied to samples taken from research volunteers in a clinical study of benign prostatic hyperplasia. PMID:23743242

  12. Measurement of tamsulosin in human serum by liquid chromatography-tandem mass spectrometry.

    PubMed

    Upreti, Rita; Homer, Natalie Z M; Naredo, Gregorio; Cobice, Diego F; Hughes, Katherine A; Stewart, Laurence H; Walker, Brian R; Andrew, Ruth

    2013-07-01

    A simple, sensitive and robust method to extract tamsulosin from human serum, and quantify by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed and validated and is applicable as a measure of compliance in clinical research. Tamsulosin was extracted from human serum (100μL) via liquid-liquid extraction with methyl tert-butyl ether (2mL) following dilution with 0.1M ammonium hydroxide (100μL), achieving 99.9% analyte recovery. Internal standard, d9-finasteride, was synthesised in-house. Analyte and internal standard were separated on an Ascentis(®) Express C18 (100mm×3mm, 2.7μm) column using a gradient elution with mobile phases methanol and 2mM aqueous ammonium acetate (5:95, v/v). Total run-time was 6min. Tamsulosin was quantified using a triple quadrupole mass spectrometer operated in multi-reaction-monitoring (MRM) mode using positive electrospray ionisation. Mass transitions monitored for quantitation were: tamsulosin m/z 409→228 and d9-finasteride m/z 382→318, with the structural formulae of ions confirmed by Fourier transform ion cyclotron resonance mass spectrometry (within 10ppm). The limit of quantitation was 0.2ng/mL, and the method was validated in the linear range 0.2-50ng/mL with acceptable inter- and intra-assay precision and accuracy and stability suitable for routine laboratory practice. The method was successfully applied to samples taken from research volunteers in a clinical study of benign prostatic hyperplasia. Copyright © 2013 The Authors. Published by Elsevier B.V. All rights reserved.

  13. Analysis of accumulation of 99mTc-octreotide and 99mTc-EDDA/HYNIC-Tyr3-octreotide in the rat kidneys.

    PubMed

    Kopecky, Martin; Semecky, Vladimir; Trejtnar, Frantisek; Laznicek, Milan; Laznickova, Alice; Nachtigal, Petr; Decristoforo, Clemens; Mather, Stephen J; Mäcke, Helmut R

    2004-02-01

    The aim of this study was to compare renal handling and distribution of (99m)Tc-octreotide and (99m)Tc-EDDA/HYNIC-Tyr(3)-octreotide (HYNIC-TOC) in rats. In kidney perfusion experiments, the renal clearance value of (99m)Tc-octreotide was three times lower than that of (99m)Tc-EDDA/HYNIC-TOC. The predominant renal excretion of (99m)Tc-EDDA/HYNIC-TOC was associated with a high and long-term renal accumulation up to 48 hrs. Microautoradiographic results indicated that (99m)Tc-EDDA/HYNIC-TOC was retained mainly in the renal medulla within the cells of the collecting ducts and in the surrounding tissue. Lower positivity was found in the proximal and distal tubular cells. We conclude that the mechanism of renal accumulation of somatostatin analogues renal accumulation is complex and that proximal tubular reabsorption is probably not the main mechanism for uptake of (99m)Tc-EDDA/HYNIC-TOC in the kidneys. The presence of the somatostatin receptors, differences in the tonicity level within kidneys and other possible mechanisms could participate in their renal accumulation.

  14. 99mTc-3P4-RGD2 Scintimammography in the Assessment of Breast Lesions: Comparative Study with 99mTc-MIBI

    PubMed Central

    Gao, Shi; Ji, Tiefeng; Wen, Qiang; Song, Yan; Zhu, Lei; Xu, Zheli; Liu, Lin

    2014-01-01

    Purpose To compare the potential application of 99mTc-3P-Arg-Gly-Asp (99mTc-3P4-RGD2) scintimammography (SMM) and 99mTc-methoxyisobutylisonitrile (99mTc-MIBI) SMM for the differentiation of malignant from benign breast lesions. Method Thirty-six patients with breast masses on physical examination and/or suspicious mammography results that required fine needle aspiration cytology biopsy (FNAB) were included in the study. 99mTc-3P4-RGD2 and 99mTc-MIBI SMM were performed with single photon emission computed tomography (SPECT) at 60 min and 20 min respectively after intravenous injection of 738±86 MBq radiotracers on a separate day. Images were evaluated by the tumor to non-tumor localization ratios (T/NT). Receiver operating characteristic (ROC) curve analysis was performed on each radiotracer to calculate the cut-off values of quantitative indices and to compare the diagnostic performance for the ability to differentiate malignant from benign diseases. Results The mean T/NT ratio of 99mTc-3P4-RGD2 in malignant lesions was significantly higher than that in benign lesions (3.54±1.51 vs. 1.83±0.98, p<0.001). The sensitivity, specificity, and accuracy of 99mTc-3P4-RGD2 SMM were 89.3%, 90.9% and 89.7%, respectively, with a T/NT cut-off value of 2.40. The mean T/NT ratio of 99mTc-MIBI in malignant lesions was also significantly higher than that in benign lesions (2.86±0.99 vs. 1.51±0.61, p<0.001). The sensitivity, specificity and accuracy of 99mTc-MIBI SMM were 87.5%, 72.7% and 82.1%, respectively, with a T/NT cut-off value of 1.45. According to the ROC analysis, the area under the curve for 99mTc-3P4-RGD2 SMM (area = 0.851) was higher than that for 99mTc-MIBI SMM (area = 0.781), but the statistical difference was not significant. Conclusion 99mTc-3P4-RGD2 SMM does not provide any significant advantage over the established 99mTc-MIBI SMM for the detection of primary breast cancer. The T/NT ratio of 99mTc-3P4-RGD2 SMM was significantly higher than that of 99m

  15. Probing Cocaine-Antibody Interactions in Buffer and Human Serum

    PubMed Central

    Ramakrishnan, Muthu; Alves De Melo, Fernando; Kinsey, Berma M.; Ladbury, John E.; Kosten, Thomas R.; Orson, Frank M.

    2012-01-01

    Background Despite progress in cocaine immunotherapy, the kinetic and thermodynamic properties of antibodies which bind to cocaine and its metabolites are not well understood. It is also not clear how the interactions between them differ in a complex matrix such as the serum present in the human body. In the present study, we have used microscale thermophoresis (MST), isothermal titration calorimetry (ITC), and surface plasmon resonance (SPR) we have evaluated the affinity properties of a representative mouse monoclonal (mAb08) as well as those of polyclonal antibodies purified from vaccinated mouse and human patient serum. Results MST analysis of fluorescently tagged mAb08 binding to cocaine reveals an approximately 15 fold decrease in its equilibrium dissociation constant in 20–50% human serum compared with that in saline buffer. A similar trend was also found using enriched polyclonal antibodies purified from vaccinated mice and patient serum, for which we have used fluorescently tagged bovine serum albumin conjugated to succinyl norcocaine (BSA-SNC). This conjugate closely mimics both cocaine and the hapten used to raise these antibodies. The ITC data also revealed that cocaine has a moderate affinity of about 2 µM to 20% human serum and very little interaction with human serum albumin or nonspecific human IgG at that concentration range. In a SPR inhibition experiment, the binding of mAb08 to immobilized BSA-SNC was inhibited by cocaine and benzoylecgonine in a highly competitive manner, whereas the purified polyclonal antibodies from vaccinated humans and mice, revealed preferential selectivity to pharmacologically active cocaine but not to the inactive metabolite benzoylecgonine. We have also developed a simple binding model to simulate the challenges associated with cocaine immunotherapy using the variable quantitative and kinetic properties of the antibodies. Conclusions High sensitivity calorimetric determination of antibody binding to cocaine and its

  16. Impact of Indocyanine Green for Sentinel Lymph Node Mapping in Early Stage Endometrial and Cervical Cancer: Comparison with Conventional Radiotracer (99m)Tc and/or Blue Dye.

    PubMed

    Buda, Alessandro; Crivellaro, Cinzia; Elisei, Federica; Di Martino, Giampaolo; Guerra, Luca; De Ponti, Elena; Cuzzocrea, Marco; Giuliani, Daniela; Sina, Federica; Magni, Sonia; Landoni, Claudio; Milani, Rodolfo

    2016-07-01

    To compare the detection rate (DR) and bilateral optimal mapping (OM) of sentinel lymph nodes (SLNs) in women with endometrial and cervical cancer using indocyanine green (ICG) versus the standard technetium-99m radiocolloid ((99m)Tc) radiotracer plus methylene or isosulfan blue, or blue dye alone. From October 2010 to May 2015, 163 women with stage I endometrial or cervical cancer (118 endometrial and 45 cervical cancer) underwent SLN mapping with (99m)Tc with blue dye, blue dye alone, or ICG. DR and bilateral OM of ICG were compared respectively with the results obtained using the standard (99m)Tc radiotracer with blue dye, or blue dye alone. SLN mapping with (99m)Tc radiotracer with blue dye was performed on 77 of 163 women, 38 with blue dye only and 48 with ICG. The overall DR of SLN mapping was 97, 89, and 100 % for (99m)Tc with blue dye, blue dye alone, and ICG, respectively. The bilateral OM rate for ICG was 85 %-significantly higher than the 58 % obtained with (99m)Tc with blue dye (p = 0.003) and the 54 % for blue dye (p = 0.001). Thirty-one women (19 %) had positive SLNs. Sensitivity and negative predictive value of SLN were 100 % for all techniques. SLNs mapping using ICG demonstrated higher DR compared to other modalities. In addition, ICG was significantly superior to (99m)Tc with blue dye in terms of bilateral OM in women with early stage endometrial and cervical cancer. The higher number of bilateral OM may consequently reduce the overall number of complete lymphadenectomies, reducing the duration and additional costs of surgical treatment.

  17. Measuring hepatic functional reserve using T1 mapping of Gd-EOB-DTPA enhanced 3T MR imaging: A preliminary study comparing with 99mTc GSA scintigraphy and signal intensity based parameters.

    PubMed

    Nakagawa, Masataka; Namimoto, Tomohiro; Shimizu, Kie; Morita, Kosuke; Sakamoto, Fumi; Oda, Seitaro; Nakaura, Takeshi; Utsunomiya, Daisuke; Shiraishi, Shinya; Yamashita, Yasuyuki

    2017-07-01

    To determine the utility of liver T1-mapping on gadolinium-ethoxybenzyl-diethylenetriamine-pentaacetic acid (Gd-EOB-DTPA) enhanced magnetic resonance (MR) imaging for the measurement of liver functional reserve compared with the signal intensity (SI) based parameters, technetium-99m-galactosyl serum albumin ( 99m Tc-GSA) scintigraphy and indocyanine green (ICG) clearance. This retrospective study included 111 patients (Child-Pugh-A 90; -B 21) performed with both Gd-EOB-DTPA enhanced liver MR imaging and 99m Tc-GSA (76 patients with ICG). Receiver operating characteristic (ROC) curve analysis was performed to compare diagnostic performances of T1-relaxation-time parameters [pre-(T1pre) and post-contrast (T1hb) Gd-EOB-DTPA], SI based parameters [relative enhancement (RE), liver-to-muscle-ratio (LMR), liver-to-spleen-ratio (LSR)] and 99m Tc-GSA scintigraphy blood clearance index (HH15)] for Child-Pugh classification. Pearson's correlation was used for comparisons among T1-relaxation-time parameters, SI-based parameters, HH15 and ICG. A significant difference was obtained for Child-Pugh classification with T1hb, ΔT1, all SI based parameters and HH15. T1hb had the highest AUC followed by RE, LMR, LSR, ΔT1, HH15 and T1pre. The correlation coefficients with HH15 were T1pre 0.22, T1hb 0.53, ΔT1 -0.38 of T1 relaxation parameters; RE -0.44, LMR -0.45, LSR -0.43 of SI-based parameters. T1hb was highest for correlation with HH15. The correlation coefficients with ICG were T1pre 0.29, T1hb 0.64, ΔT1 -0.42 of T1 relaxation parameters; RE -0.50, LMR -0.61, LSR -0.58 of SI-based parameters; 0.64 of HH15. Both T1hb and HH15 were highest for correlation with ICG. T1 relaxation time at post-contrast of Gd-EOB-DTPA (T1hb) was strongly correlated with ICG clearance and moderately correlated HH15 with 99m Tc-GSA. T1hb has the potential to provide robust parameter of liver functional reserve. Copyright © 2017 Elsevier B.V. All rights reserved.

  18. Jejunal variceal bleeding after esophageal transection in a patient with idiopathic portal hypertension.

    PubMed

    Migou, S; Hashizume, M; Tsugawa, K; Kishihara, F; Kawanaka, H; Ohta, M; Tanoue, K; Kuroiwa, T; Kawamoto, K; Sugimachi, K

    1998-01-01

    This report describes a 38-year-old man with massive gastrointestinal bleeding from jejunal varices. He had been previously diagnosed to have idiopathic portal hypertension and esophageal varices, and had undergone an esophageal transection 8 years earlier. The pre-operative diagnosis was a suspected hemorrhage from the small intestine as visualized by 99mTc-HSAD scintigraphy (technetium 99m-labeled human serum albumin D-type) and was not considered to be repeated massive lower GI tract bleeding. An exploratory laparotomy was performed, and intra-operative endoscopy revealed active bleeding from the jejunal varices. A partial resection of the small intestine resulted in a complete resolution of the bleeding. A review of the literature thereafter disclosed twelve previously reported cases of jejunal variceal bleeding.

  19. Rapid diagnosis of occult abscesses using sup 99m Tc-labeled monoclonal antibodies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coons, T.A.; Rhodes, B.A.; Thakur, M.L.

    1991-01-01

    Acute infections, such as appendicitis and occult infections in AIDS patients, can be diagnosed within two hours by gamma scintigraphy after i.v. administration of {sup 99m}Tc labeled antibodies reactive with human granulocytes. The antibody, murine IgM anti-SSEA-1, is partially reduced using Sn(II) to expose and protect reactive sulfide groups. The antibody is then purified, stannous tartrate and stabilizers are added, and the mixture is lyophilized. To label, sodium pertechnetate is added. After a 15 minute incubation the tracer drug is injected. The rate of accumulation and degree of concentration at the site of infection is presumptively determinative of the severitymore » of the infection. Acceptance criteria and tests for the {sup 99m}Tc labeled antibody product have been established and validated. Greater than 93% of the {sup 99m}Tc is firmly bound to the protein as determined by quantitative HPLC. Radiochemical impurities, colloidal {sup 99m}Tc and free pertechnetate are together less than 4% as determined by thin layer chromatography. The immunoreactive fraction, measured by binding to solid phase antigen, and affinity measured be ELISA, are unchanged by the {sup 99m}Tc-direct labeling process. Two hour blood clearance in rats is within 90% of the value of the {sup 125}I labeled analog. The immunoreactive fraction decreases less than 10% when incubated in human plasma for 24 hours. This method has been compared to other direct labeling methods, and found to give higher radiochemical yields. 5 figs.« less

  20. Technetium-99m-HMPAO labeled leukocyte single photon emission computerized tomography (SPECT) for assessing Crohn's disease extent and intestinal infiltration.

    PubMed

    Biancone, L; Schillaci, O; Capoccetti, F; Bozzi, R M; Fina, D; Petruzziello, C; Geremia, A; Simonetti, G; Pallone, F

    2005-02-01

    Scintigraphy using radiolabeled leukocytes is a useful technique for assessing intestinal infiltration in Crohn's disease (CD). However, limits of planar images include overlapping activity in other organs and low specificity. To investigate the usefulness of (99m)Tc-HMPAO (hexametyl propylene amine oxime) labeled leukocyte single photon emission computerized tomography (SPECT) for assessing CD lesions, in comparison with planar images. Twenty-two inflammatory bowel disease patients (19 CD; 2 ulcerative colitis, UC; 1 ileal pouch) assessed by conventional endoscopy or radiology were enrolled. Leukocytes were labeled with (99m)Tc-HMPAO. SPECT images were acquired at 2 h and planar images at 30 min and 2 h. Bowel uptake was quantitated in nine regions (score 0-3). Both SPECT and planar images detected a negative scintigraphy (score 0) in the UC patient with no pouchitis and a positive scintigraphy (score 1-3) in the 21 patients showing active inflammation by conventional techniques. SPECT showed a higher global score than planar images (0.71 +/- 0.09 vs 0.30 +/- 0.05; p < 0.001), and in particular in the right iliac fossa (p= 0.003), right and left flank (p < 0.001; p= 0.02), hypogastrium (p= 0.002), and mesogastrium (p < 0.001). SPECT provided a better visualization and a higher uptake than planar images in patients with ileal and ileocolonic CD (6.45 +/- 0.82 vs 2.8 +/- 0.55, p < 0.001; 5.5 +/- 1.6 vs 2.6 +/- 0.7, p= 0.03), and with perianal CD (6.6 +/- 1.6 vs 3.4 +/- 1.2; p= 0.03). (99m)Tc-HMPAO labeled leukocyte SPECT provides a more detailed visualization of CD lesions than planar images. This technique may better discriminate between intestinal and bone marrow uptake, thus being useful for assessing CD lesions within the pelvis, including perianal disease.

  1. Use of quantitative SPECT/CT reconstruction in 99mTc-sestamibi imaging of patients with renal masses.

    PubMed

    Jones, Krystyna M; Solnes, Lilja B; Rowe, Steven P; Gorin, Michael A; Sheikhbahaei, Sara; Fung, George; Frey, Eric C; Allaf, Mohamad E; Du, Yong; Javadi, Mehrbod S

    2018-02-01

    Technetium-99m ( 99m Tc)-sestamibi single-photon emission computed tomography/computed tomography (SPECT/CT) has previously been shown to allow for the accurate differentiation of benign renal oncocytomas and hybrid oncocytic/chromophobe tumors (HOCTs) apart from other malignant renal tumor histologies, with oncocytomas/HOCTs showing high uptake and renal cell carcinoma (RCC) showing low uptake based on uptake ratios from non-quantitative single-photon emission computed tomography (SPECT) reconstructions. However, in this study, several tumors fell close to the uptake ratio cutoff, likely due to limitations in conventional SPECT/CT reconstruction methods. We hypothesized that application of quantitative SPECT/CT (QSPECT) reconstruction methods developed by our group would provide more robust separation of hot and cold lesions, serving as an imaging framework on which quantitative biomarkers can be validated for evaluation of renal masses with 99m Tc-sestamibi. Single-photon emission computed tomography data were reconstructed using the clinical Flash 3D reconstruction and QSPECT methods. Two blinded readers then characterized each tumor as hot or cold. Semi-quantitative uptake ratios were calculated by dividing lesion activity by background renal activity for both Flash 3D and QSPECT reconstructions. The difference between median (mean) hot and cold tumor uptake ratios measured 0.655 (0.73) with the QSPECT method and 0.624 (0.67) with the conventional method, resulting in increased separation between hot and cold tumors. Sub-analysis of 7 lesions near the separation point showed a higher absolute difference (0.16) between QPSECT and Flash 3D mean uptake ratios compared to the remaining lesions. Our finding of improved separation between uptake ratios of hot and cold lesions using QSPECT reconstruction lays the foundation for additional quantitative SPECT techniques such as SPECT-UV in the setting of renal 99m Tc-sestamibi and other SPECT/CT exams. With robust

  2. Initial direct comparison of 99mTc-TOC and 99mTc-TATE in identifying sites of disease in patients with proven GEP NETs.

    PubMed

    Cwikla, Jaroslaw B; Mikolajczak, Renata; Pawlak, Dariusz; Buscombe, John R; Nasierowska-Guttmejer, Anna; Bator, Andrzej; Maecke, Helmut R; Walecki, Jerzy

    2008-07-01

    The imaging of neuroendocrine tumors has become one of the most significant areas in nuclear oncology. In an attempt to provide high-quality imaging and possible sensitivity at a reduced cost, time, and radiation dose, several (99m)Tc agents have been proposed. The aim of this initial study was to compare the tumor uptake and biodistribution of 2 new 6-hydrazinopyridine-3-carboxylic acid (HYNIC)-derivatized Tyr(3)-octreotide analogs, (99m)Tc-[HYNIC,Tyr(3)]octreotide ((99m)Tc-TOC) and (99m)Tc-[HYNIC,Tyr(3),Thr(8)]octreotide ((99m)Tc-TATE), in patients with somatostatin receptor-expressing tumors. Each of 12 patients with proven gastrointestinal pancreatic neuroendocrine tumors received a mean activity of 520 MBq of (99m)Tc-TOC and (99m)Tc-TATE. Scintigraphy with both tracers was performed 3-4 h after their injection using standard whole-body and SPECT imaging. The images were reviewed subjectively by 2 readers, who reported tumor uptake lesion by lesion. Both radiotracers demonstrated concordance between the results in 7 patients (58%). In total, 110 sites of disease were identified with (99m)Tc-TOC, compared with 115 with (99m)Tc-TATE. There was 1 case in which (99m)Tc-TOC identified sites of disease not seen on (99m)Tc-TATE imaging but 4 cases in which some sites of disease were seen with (99m)Tc-TATE and not (99m)Tc-TOC. In this initial study, both tracers seem to show similar sites of tumor, with (99m)Tc-TATE having a slight edge in the total number of lesions seen, especially in lymph node metastases.

  3. Preclinical evaluation of 99mTc(CO)3-aspartic-N-monoacetic acid, 99mTc(CO)3(ASMA), a new renal radiotracer with pharmacokinetic properties comparable to 131I-OIH

    PubMed Central

    Lipowska, Malgorzata; Klenc, Jeffrey; Marzilli, Luigi G.; Taylor, Andrew T.

    2014-01-01

    In an ongoing effort to develop a renal tracer with pharmacokinetic properties comparable to PAH and superior to those of both 99mTc-MAG3 and 131I-OIH, we evaluated a new renal tricarbonyl radiotracer based on the aspartic-N-monoacetic acid ligand, 99mTc(CO)3(ASMA). The ASMA ligand features two carboxyl groups and an amine function for the coordination of the {99mTc(CO)3}+ core as well as a dangling carboxylate to facilitate rapid renal clearance. Methods rac-ASMA and L-ASMA were labeled with a 99mTc-tricarbonyl precursor and radiochemical purity of the labeled products was determined by HPLC. Using 131I-OIH as an internal control, we evaluated biodistribution in normal rats with 99mTc(CO)3(ASMA) isomers and in rats with renal pedicle ligation with 99mTc(CO)3(rac-ASMA). Clearance studies were conducted in 4 additional rats. In vitro radiotracer stability was determined in PBS buffer pH 7.4 and in challenge studies with cysteine and histidine. 99mTc(CO)3(ASMA) metabolites in urine were analyzed by HPLC. Results Both 99mTc(CO)3(ASMA) preparations had > 99% radiochemical purity and were stable in PBS buffer pH 7.4 for 24 h. Challenge studies on both revealed no significant displacement of the ligand. In normal rats, % injected dose in urine at 10 and 60 min for both preparations averaged 103% and 106% that of 131I-OIH, respectively. The renal clearances of 99mTc(CO)3(rac-ASMA) and 131I-OIH were comparable (P = 0.48). The tracer was excreted unchanged in the urine, proving its in vivo stability. In pedicle-ligated rats, 99mTc(CO)3(rac-ASMA) had less excretion into the bowel (P < 0.05) and was better retained in the blood (P < 0.05) than 131I-OIH. Conclusion Both 99mTc(CO)3(ASMA) complexes have pharmacokinetic properties in rats comparable to or superior to those of 131I-OIH, and human studies are warranted for their further evaluation. PMID:22717977

  4. Technetium-99 and strontium-90: Abundance determination at ultratrace sensitivity by AMS as signatures of undeclared nuclear reprocessing activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    McAninch, J.E.; Proctor, I.D.

    1995-03-01

    The purpose of this White Paper is to examine the use of the ultratrace technique Accelerator Mass Spectrometry (AMS) to lower detection limits for {sup 99}Tc and {sup 90}Sr, and to examine the utility of these isotopes as signatures of a convert reprocessing facility. The International Atomic Energy Agency (IAEA) has committed to improving the effectiveness of the IAEA Safeguards System. This is in some degree a result of the discovery in 1991 of an undeclared Iraqi EMIS program. Recommendations from the March 1993 Consultants Group Meeting have resulted in several studies and follow on field trials to identify environmentalmore » signatures from covert nuclear fuel reprocessing activity. In particular, the April, 1993 reports of the Standing Advisory Group on Safeguards Implementation (SAGSI) identified the long-lived radioisotopes Technetium-99 and strontium-90 as two reliable signatures of fuel reprocessing activity. This report also suggested pathways in the chemical processing of irradiated fuel where these elements would be volatilized and potentially released in amounts detectable with ultratrace sensitivity techniques. Based on measured {sup 99}Tc background levels compiled from a variety of sources, it is estimated that AMS can provide 10% measurements of environmental levels of {sup 99}Tc in a few minutes using modestly sized samples: a few grams for soils, plants, or animal tissues; one to several liters for rain or seawater samples; and tens to hundreds of cubic meters for air sampling. Small sample sizes and high sample throughput result in significant increases in feasibility, cost effectiveness, and quality of data for a regional monitoring program. Similar results are expected for {sup 90}Sr.« less

  5. Quality of 99mTcO4- from 99Mo Produced by 100Mo(n,2n)99Mo

    NASA Astrophysics Data System (ADS)

    Nagai, Yasuki; Nakahara, Yuto; Kawabata, Masako; Hatsukawa, Yuichi; Hashimoto, Kazuyuki; Saeki, Hideya; Motoishi, Shoji; Ohta, Akio; Shiina, Takayuki; Kawauchi, Yukimasa

    2017-05-01

    The pharmaceutical quality of 99mTc pertechnetate solution obtained from 99Mo, the 100Mo(n,2n) reaction product, was investigated for the first time with an emphasis on the nonradioactive Mo content and endotoxin concentration. They were less than the tolerance dose given in international guidelines and the established upper limit in an international pharmacopoeia, respectively. Four other quality control tests commonly used for a commercially available 99mTc pertechnetate solution also demonstrated to meet the United States Pharmacopeia requirements. The results strongly support that the thermochromatographic separation method used to separate 99mTc from 99Mo can be a promising substitute for the fission product 99Mo.

  6. Influence of Storage Temperature on Radiochemical Purity of 99mTc-Radiopharmaceuticals.

    PubMed

    Uccelli, Licia; Boschi, Alessandra; Martini, Petra; Cittanti, Corrado; Bertelli, Stefania; Bortolotti, Doretta; Govoni, Elena; Lodi, Luca; Romani, Simona; Zaccaria, Samanta; Zappaterra, Elisa; Farina, Donatella; Rizzo, Carlotta; Giganti, Melchiore; Bartolomei, Mirco

    2018-03-15

    The influence of effective room temperature on the radiochemical purity of 99m Tc-radiopharmaceuticals was reported. This study was born from the observation that in the isolators used for the preparation of the 99m Tc-radiopharmaceuticals the temperatures can be higher than those reported in the commercial illustrative leaflets of the kits. This is due, in particular, to the small size of the work area, the presence of instruments for heating, the continuous activation of air filtration, in addition to the fact that the environment of the isolator used for the 99m Tc-radiopharmaceuticals preparation and storage is completely isolated and not conditioned. A total of 244 99m Tc-radiopharmaceutical preparations (seven different types) have been tested and the radiochemical purity was checked at the end of preparation and until the expiry time. Moreover, we found that the mean temperature into the isolator was significantly higher than 25 °C, the temperature, in general, required for the preparation and storage of 99m Tc-radiopharmaceuticals. Results confirmed the radiochemical stability of radiopharmaceutical products. However, as required in the field of quality assurance, the impact that different conditions than those required by the manufacturer on the radiopharmaceuticals quality have to be verified before human administration.

  7. Myocardial impairment detected by late gadolinium enhancement in hypertrophic cardiomyopathy: comparison with 99mTc-MIBI/tetrofosmin and 123I-BMIPP SPECT.

    PubMed

    Hashimura, Hiromi; Kiso, Keisuke; Yamada, Naoaki; Kono, Atsushi; Morita, Yoshiaki; Fukushima, Kazuto; Higashi, Masahiro; Noguchi, Teruo; Ishibashi-Ueda, Hatsue; Naito, Hiroaki; Sugimura, Kazuro

    2013-06-17

    Myocardial fibrosis is considered to be an important factor in myocardial dysfunction and sudden cardiac death in hypertrophic cardiomyopathy (HCM). The purpose of this study was to compare myocardial fibrosis detected by late gadolinium enhancement (LGE) on cardiac MRI with myocardial perfusion and fatty acid metabolism assessed by single photon emission computed tomography in HCM. We retrospectively evaluated 20 consecutive HCM patients (female, 7; mean age, 53.4 years) who underwent LGE, technetium-99m methoxyisobutylisonitrile/tetrofosmin (99mTc-MIBI/tetrofosmin), and iodine-123 beta-methyl-iodophenylpentadecanoic acid (123I-BMIPP) imaging. We calculated the myocardium-to-lumen signal ratio (M/L) for LGE in 17 segments based on the American Heart Association statement. Scoring of 99mTc-MIBI/tetrofosmin (PI) and 123I-BMIPP (BM) was performed for each segment using a 5-point scale (0, normal; 4, highly decreased). Nineteen of 20 patients (95%) and 153 of 340 segments (45%) showed LGE. M/Ls were 0.42±0.16, 0.55±0.17, and 0.65±0.24 in PI0/BM0, PI0/BM1-4 and PI1-4/BM1-4, respectively. All M/Ls were significantly higher than that of a normal control (0.34±0.14) (p<0.001). Myocardial fibrosis in HCM can occur despite normal perfusion and fatty acid metabolism, and is more strongly associated with disorders of fatty acid metabolism than with perfusion abnormalities. M/L may be a useful indicator of disease severity.

  8. [Course of ejection fraction, regurgitation fraction and ventricular volumes during exertion in chronic aortic insufficiency. Study using technetium 99m gamma-cineangiography].

    PubMed

    Bassand, J P; Faivre, R; Berthout, P; Cardot, J C; Verdenet, J; Bidet, R; Maurat, J P

    1985-06-01

    Previous studies have shown that variations of the ejection fraction (EF) during exercise were representative of the contractile state of the left ventricle: an increased EF on effort is considered to be physiological, whilst a decrease would indicate latent LV dysfunction unmasked during exercise. This hypothesis was tested by performing Technetium 99 gamma cineangiography at equilibrium under basal conditions and at maximal effort in 8 healthy subjects and 44 patients with pure, severe aortic regurgitation to measure the ejection and regurgitant fractions and the variations in end systolic and end diastolic LV volume. In the control group the EF increased and end systolic volume decreased significantly on effort whilst the regurgitant fraction and end diastolic volume were unchanged. In the 44 patients with aortic regurgitation no significant variations in EF, end systolic and end diastolic volumes were observed because the individual values were very dispersed. Variations of the EF and end systolic volume were inversely correlated. The regurgitant fraction decreased significantly on effort. Based on the variations of the EF and end systolic volume three different types of response to effort could be identified: in 7 patients, the EF increased on effort and end systolic volume decreased without any significant variation in the end diastolic volume, as in the group of normal control subjects; in 22 patients, a reduction in EF was observed on effort, associated with an increased end systolic volume. These changes indicated latent IV dysfunction inapparent at rest and unmasked by exercise; in a third group of 15 patients, the EF decreased on effort despite a physiological decrease in end systolic volume due to a greater decrease in end diastolic volume.(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Measurement of pulmonary epithelial permeability with /sup 99m/Tc-DTPA aerosol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coates, G.; O'Brodovich, H.

    1986-10-01

    The rate at which inhaled aerosol of /sup 99m/Tc-diethylenetriamine pentaacetate (DTPA) leaves the lung by diffusion into the vascular space can be measured with a gamma camera or simple probe. In normal humans, /sup 99m/Tc-DTPA clears from the lung with a half time of about 80 minutes. Many acute and chronic conditions that alter the integrity of the pulmonary epithelium cause an increased clearance rate. Thus cigarette smoking, alveolitis from a variety of causes, adult respiratory distress syndrome (ARDS), and hyaline membrane disease (HMD) in the infant have all been shown to be associated with rapid pulmonary clearance of /supmore » 99m/Tc-DTPA. Rapid clearance is also promoted by increased lung volume and decreased surfactant activity. Although the mechanism of increased clearance in pathological states is not known, the /sup 99m/Tc-DTPA lung-clearance technique has great potential clinically, particularly in patients at risk from ARDS and HMD and in the diagnosis and follow-up of alveolitis. 58 references.« less

  10. Biokinetics and dosimetric studies about 99mTc(V)-DMSA distribution.

    PubMed

    Correia, M B L; Magnata, S S L P; Silva, I M S; Catanho, M T J A; Lima, F F

    2010-05-10

    Research for radiodiagnostic agents should considerate biological critical parameters which will give own contribution on the absorbed dose. The dimercaptosuccinic acid (DMSA) labeled with (99m)Tc(V) is a radiopharmaceutical which has well established role in medullar thyroid carcinoma and has been proposed in evaluation of bone metastasis. This work studied the biokinetics and dosimetry of (99m)Tc(V)-DMSA by animal model. The (99m)Tc(V)-DMSA was prepared from a (III)DMSA kit alkalized. Mice (n=5) received (99m)Tc(V)DMSA i.v., they were sacrificed (30 min, 1h, 5h and 12h), the organs excised and the activities measured by a gamma counter. The results were evaluated based on %activity/g and the absorbed dose was estimated (MIRDOSE 3.0 program) by extrapolation of data from animal to human scale. The results showed the majority of organs reached the top uptake at 30 min, the greatest kidney uptake was (4.81 +/- 1.38)% activity/g, while the bone presented its highest uptake at 1h (5.49+/- 0.47)% activity/g, after 1h all the organs had activity exponential decrease. The biokinetic profile of (99m)Tc(V)-DMSA was well established, allowing quantifying of residence time, and the radiation dose estimates were made for this agent. About the absorbed dose, the preliminary results showed higher value to bone, being the soft tissue dose relatively low.

  11. Biodistribution and pharmacokinetics of the (99m)Tc labeled human elastase inhibitor, elafin, in rats.

    PubMed

    Kaschwich, Mark; Lützen, Ulf; Zhao, Yi; Tjiong, Angelina; Marx, Marlies; Haenisch, Sierk; Wiedow, Oliver; Preuss, Stefanie; Culman, Juraj; Zuhayra, Maaz

    2016-04-01

    Elafin is a potent reversible inhibitor of the pro-inflammatory proteases leukocyte elastase and protease 3. It is currently in clinical development for the use in postoperative inflammatory diseases. We investigated the pharmacokinetics of (99m)Tc-labeled elafin ((99m)Tc-Elafin) in blood and individual organs in rat after bolus intravenous injection using the single photon emission tomography (SPECT). (99m)Tc-Elafin predominantly accumulated in the kidney reaching a maximum of 8.5% ± 0.1% of the injected dose per gram (ID/g) at 5 min post injection (p.i) and decreased only slowly during 24 h. In contrast, the initially high radio activity recorded in the other organs rapidly decreased parallel to the radioactivity detected in blood. The blood kinetics fits to a two compartment kinetics model. The radio activity in the dissected kidney was 4.98 ± 1.24%ID/g 24 h p.i, while in other organs, including the brain, no accumulation of (99m)Tc-Elafin was detected. At this time point 30% of the detected radioactivity in the kidney was identified to be not metabolized (99m)Tc-Elafin. In conclusion, the blood and organ-specific kinetic data provide a basis for planning of adequate dosing regimens and the high accumulation of intact elafin in the kidney favors clinical developments targeting inflammatory kidney diseases, such as chronic allograft nephropathy after kidney transplantation. Copyright © 2016 The Japanese Society for the Study of Xenobiotics. Published by Elsevier Ltd. All rights reserved.

  12. Kit for the selective labeling of red blood cells in whole blood with [sup 99]Tc

    DOEpatents

    Srivastava, S.C.; Babich, J.W.; Straub, R.; Richards, P.

    1992-05-26

    Disclosed herein are a method and kit for the preparation of [sup 99m]Tc labeled red blood cells using whole blood in a closed sterile system containing stannous tin in a form such that it will enter the red blood cells and be available therein for reduction of technetium. No Drawings

  13. Development of Tyrosine-Based Radiotracer 99mTc-N4-Tyrosine for Breast Cancer Imaging

    PubMed Central

    Kong, Fan-Lin; Ali, Mohammad S.; Rollo, Alex; Smith, Daniel L.; Zhang, Yinhan; Yu, Dong-Fang; Yang, David J.

    2012-01-01

    The purpose of this study was to develop an efficient way to synthesize 99mTc-O-[3-(1,4,8,11-tetraazabicyclohexadecane)-propyl]-tyrosine (99mTc-N4-Tyrosine), a novel amino acid-based radiotracer, and evaluate its potential in breast cancer gamma imaging. Precursor N4-Tyrosine was synthesized using a 5-step procedure, and its total synthesis yield was 38%. It was successfully labeled with 99mTc with high radiochemical purity (>95%). Cellular uptake of 99mTc-N4-Tyrosine was much higher than that of 99mTc-N4 and the clinical gold standard 18F-2-deoxy-2-fluoro-glucose (18F-FDG) in rat breast tumor cells in vitro. Tissue uptake and dosimetry estimation in normal rats revealed that 99mTc-N4-Tyrosine could be safely administered to humans. Evaluation in breast tumor-bearing rats showed that although 99mTc-N4-Tyrosine appeared to be inferior to 18F-FDG in distinguishing breast tumor tissue from chemical-induced inflammatory tissue, it had high tumor-to-muscle uptake ratios and could detect breast tumors clearly by planar scintigraphic imaging. 99mTc-N4-Tyrosine could thus be a useful radiotracer for use in breast tumor diagnostic imaging. PMID:22496612

  14. Creatine kinase MB isoenzyme in dermatomyositis: a noncardiac source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Larca, L.J.; Coppola, J.T.; Honig, S.

    1981-03-01

    Three patients with polymyositis had elevated serum levels of creatine kinase MB isoenzyme. The presence of this isoenzyme is used extensively to diagnose myocardial infarction, but the isoenzyme is also found in sera of patients with primary muscular and neuromuscular disorders. Researchers studied cardiac function in two of our patients with electrocardiograms, technetium stannous pyrophosphate scanning, and technetium 99m-labeled erythrocyte gated blood pool imaging and in the third patient by postmortem examination. There was no evidence of myocardial involvement to account for the high serum levels of isoenzyme. Creatine kinase MB in the sera of patients with polymyositis does notmore » necessarily indicate myocardial necrosis.« less

  15. Early detection of rheumatoid arthritis in rats and humans with 99mTc-3PRGD2 scintigraphy: imaging synovial neoangiogenesis.

    PubMed

    Wu, Yu; Zhang, Guojian; Wang, Xiangcheng; Zhao, Zhenfang; Wang, Tao; Wang, Xuemei; Li, Xiao-Feng

    2017-01-24

    To validate 99mTc-labeled arginylglycylaspartic acid (99mTc-3PRGD2) scintigraphy as a means to image synovial neoangiogenesis in joints afflicted by rheumatoid arthritis and to investigate its potential in the early detection and management of rheumatoid arthritis. Rheumatoid arthritis and osteoarthritis were generated in Sprague Dawley rats by type II collagen immunization and papain injection, respectively. Rats were imaged with 99mTc-3PRGD2 and 99mTc- methyl diphosphonate (99mTc MDP). X-ray images were also obtained and assessed by a radiologist. Immunohistochemistry of αvβ3 and CD31confirmed the onset of synovial neoangiogenesis. The effect of bevacizumab on rheumatoid arthritis was followed with 99mTc-3PRGD2 scintigraphy. A patient with rheumatoid arthritis and a healthy volunteer were scanned with 99mTc-3PRGD2. Two weeks after immunization, a significant increase in 99mTc-3PRGD2 was observed in the joints of the rheumatoid arthritis model though uptake in osteoarthritis model and untreated controls was low. 99mTc-MDP whole body scans failed to distinguish early rheumatoid arthritis joints from healthy controls. The expression of αvβ3 and CD31was significantly higher in the joints of rheumatoid arthritis rats compared to normal controls. In serial 99mTc-3PRGD2 scintigraphy studies, 99mTc-3PRGD2 uptake increased in parallel with disease progression. Bevacizumab anti-angiogenetic therapy both improved the symptoms of the rheumatoid arthritis rats and significantly decreased 99mTc-3PRGD2 uptake. Significantly higher 99mTc-3PRGD2 accumulation was also observed in rheumatoid arthritis joints in the patient. Our findings indicate that 99mTc-3PRGD2 scintigraphy could detect early rheumatoid arthritis by imaging the associated synovial neoangiogenesis, and may be useful in disease management.

  16. Method for the production of .sup.99m Tc compositions from .sup.99 Mo-containing materials

    DOEpatents

    Bennett, Ralph G.; Christian, Jerry D.; Grover, S. Blaine; Petti, David A.; Terry, William K.; Yoon, Woo Y.

    1998-01-01

    An improved method for producing .sup.99m Tc compositions from .sup.99 Mo compounds. .sup.100 Mo metal or .sup.100 MoO.sub.3 is irradiated with photons in a particle (electron) accelerator to ultimately produce .sup.99 MoO.sub.3. This composition is then heated in a reaction chamber to form a pool of molten .sup.99 MoO.sub.3 with an optimum depth of 0.5-5 mm. A gaseous mixture thereafter evolves from the molten .sup.99 MoO.sub.3 which contains vaporized .sup.99 MoO.sub.3, vaporized .sup.99m TcO.sub.3, and vaporized .sup.99m TcO.sub.2. This mixture is then combined with an oxidizing gas (O.sub.2(g)) to generate a gaseous stream containing vaporized .sup.99m Tc.sub.2 O.sub.7 and vaporized .sup.99 MoO.sub.3. Next, the gaseous stream is cooled in a primary condensation stage in the reaction chamber to remove vaporized .sup.99 MoO.sub.3. Cooling is undertaken at a specially-controlled rate to achieve maximum separation efficiency. The gaseous stream is then cooled in a sequential secondary condensation stage to convert vaporized .sup.99m Tc.sub.2 O.sub.7 into a condensed .sup.99m Tc-containing reaction product which is collected.

  17. Method for the production of {sup 99m}Tc compositions from {sup 99}Mo-containing materials

    DOEpatents

    Bennett, R.G.; Christian, J.D.; Grover, S.B.; Petti, D.A.; Terry, W.K.; Yoon, W.Y.

    1998-09-01

    An improved method is described for producing {sup 99m}Tc compositions from {sup 99}Mo compounds. {sup 100}Mo metal or {sup 100}MoO{sub 3} is irradiated with photons in a particle (electron) accelerator to ultimately produce {sup 99}MoO{sub 3}. This composition is then heated in a reaction chamber to form a pool of molten {sup 99}MoO{sub 3} with an optimum depth of 0.5--5 mm. A gaseous mixture thereafter evolves from the molten {sup 99}MoO{sub 3} which contains vaporized {sup 99}MoO{sub 3}, vaporized {sup 99m}TcO{sub 3}, and vaporized {sup 99m}TcO{sub 2}. This mixture is then combined with an oxidizing gas (O{sub 2(g)}) to generate a gaseous stream containing vaporized {sup 99m}Tc{sub 2}O{sub 7} and vaporized {sup 99}MoO{sub 3}. Next, the gaseous stream is cooled in a primary condensation stage in the reaction chamber to remove vaporized {sup 99}MoO{sub 3}. Cooling is undertaken at a specially-controlled rate to achieve maximum separation efficiency. The gaseous stream is then cooled in a sequential secondary condensation stage to convert vaporized {sup 99m}Tc{sub 2}O{sub 7} into a condensed {sup 99m}Tc-containing reaction product which is collected. 1 fig.

  18. Synthesis and preliminary evaluation of a new (99m)tc labeled substance p analogue as a potential tumor imaging agent.

    PubMed

    Mozaffari, Saeed; Erfani, Mostafa; Beiki, Davood; Johari Daha, Fariba; Kobarfard, Farzad; Balalaie, Saeed; Fallahi, Babak

    2015-01-01

    Neurokinin 1 receptors (NK1R) are overexpressed on several types of important human cancer cells. Substance P (SP) is the most specific endogenous ligand known for NK1Rs. Accordingly,a new SP analogue was synthesized and evaluated for detection of NK1R positive tumors.[6-hydrazinopyridine-3-carboxylic acid (HYNIC)-Tyr(8)-Met(O)(11)-SP] was synthesized and radiolabeled with (99m)Tc using ethylenediamine-N,N'-diacetic acid (EDDA)and Tricine as coligands. Common physicochemical properties of radioconjugate were studied and in-vitro cell line biological tests were accomplished to determine the receptor mediated characteristics. In-vivo biodistribution in normal and tumor bearingnude mice was also assessed. The cold peptide was prepared in high purity (>99%) and radiolabeled with (99m)Tc at high specific activities (84-112GBq/µmol) with an acceptable labeling yield (>95%). The radioconjugate was stable in-vitro in the presence of human serum and showed 44% protein binding to human serumalbumin. In-vitro cell line studies on U373MG cells showed an acceptable uptake up to 4.91 ± 0.22% with the ratio of 60.21 ± 1.19% for its specific fraction and increasing specific internalization during 4 h. Receptor binding assays on U373MG cells indicated a mean Kd of 2.46 ± 0.43 nM and Bmax of 128925 ± 8145 sites/cell. In-vivo investigations determined the specific tumor uptake in 3.36 percent of injected dose per gram (%ID/g) for U373MG cells and noticeable accumulations of activity in the intestines and lung. Predominant renal excretion pathway was demonstrated. Therefore, this new radiolabeled peptide could be a promising radiotracer for detection of NK1R positive primary or secondary tumors.

  19. Synthesis and Preliminary Evaluation of a New 99mTc Labeled Substance P Analogue as a Potential Tumor Imaging Agent

    PubMed Central

    Mozaffari, Saeed; Erfani, Mostafa; Beiki, Davood; Johari Daha, Fariba; Kobarfard, Farzad; Balalaie, Saeed; Fallahi, Babak

    2015-01-01

    Neurokinin 1 receptors (NK1R) are overexpressed on several types of important human cancer cells. Substance P (SP) is the most specific endogenous ligand known for NK1Rs. Accordingly,a new SP analogue was synthesized and evaluated for detection of NK1R positive tumors.[6-hydrazinopyridine-3-carboxylic acid (HYNIC)-Tyr8-Met(O)11-SP] was synthesized and radiolabeled with 99mTc using ethylenediamine-N,N'-diacetic acid (EDDA)and Tricine as coligands. Common physicochemical properties of radioconjugate were studied and in-vitro cell line biological tests were accomplished to determine the receptor mediated characteristics. In-vivo biodistribution in normal and tumor bearingnude mice was also assessed. The cold peptide was prepared in high purity (>99%) and radiolabeled with 99mTc at high specific activities (84-112GBq/µmol) with an acceptable labeling yield (>95%). The radioconjugate was stable in-vitro in the presence of human serum and showed 44% protein binding to human serumalbumin. In-vitro cell line studies on U373MG cells showed an acceptable uptake up to 4.91 ± 0.22% with the ratio of 60.21 ± 1.19% for its specific fraction and increasing specific internalization during 4 h. Receptor binding assays on U373MG cells indicated a mean Kd of 2.46 ± 0.43 nM and Bmax of 128925 ± 8145 sites/cell. In-vivo investigations determined the specific tumor uptake in 3.36 percent of injected dose per gram (%ID/g) for U373MG cells and noticeable accumulations of activity in the intestines and lung. Predominant renal excretion pathway was demonstrated. Therefore, this new radiolabeled peptide could be a promising radiotracer for detection of NK1R positive primary or secondary tumors. PMID:25561916

  20. Quantitative single-photon emission computed tomography/computed tomography for technetium pertechnetate thyroid uptake measurement

    PubMed Central

    Lee, Hyunjong; Kim, Ji Hyun; Kang, Yeon-koo; Moon, Jae Hoon; So, Young; Lee, Won Woo

    2016-01-01

    Abstract Objectives: Technetium pertechnetate (99mTcO4) is a radioactive tracer used to assess thyroid function by thyroid uptake system (TUS). However, the TUS often fails to deliver accurate measurements of the percent of thyroid uptake (%thyroid uptake) of 99mTcO4. Here, we investigated the usefulness of quantitative single-photon emission computed tomography/computed tomography (SPECT/CT) after injection of 99mTcO4 in detecting thyroid function abnormalities. Materials and methods: We retrospectively reviewed data from 50 patients (male:female = 15:35; age, 46.2 ± 16.3 years; 17 Graves disease, 13 thyroiditis, and 20 euthyroid). All patients underwent 99mTcO4 quantitative SPECT/CT (185 MBq = 5 mCi), which yielded %thyroid uptake and standardized uptake value (SUV). Twenty-one (10 Graves disease and 11 thyroiditis) of the 50 patients also underwent conventional %thyroid uptake measurements using a TUS. Results: Quantitative SPECT/CT parameters (%thyroid uptake, SUVmean, and SUVmax) were the highest in Graves disease, second highest in euthyroid, and lowest in thyroiditis (P < 0.0001, Kruskal–Wallis test). TUS significantly overestimated the %thyroid uptake compared with SPECT/CT (P < 0.0001, paired t test) because other 99mTcO4 sources in addition to thyroid, such as salivary glands and saliva, contributed to the %thyroid uptake result by TUS, whereas %thyroid uptake, SUVmean and SUVmax from the SPECT/CT were associated with the functional status of thyroid. Conclusions: Quantitative SPECT/CT is more accurate than conventional TUS for measuring 99mTcO4 %thyroid uptake. Quantitative measurements using SPECT/CT may facilitate more accurate assessment of thyroid tracer uptake. PMID:27399139

  1. Process for preparing radiopharmaceuticals

    DOEpatents

    Barak, Morton; Winchell, Harry S.

    1977-01-04

    A process for the preparation of technetium-99m labeled pharmaceuticals is disclosed. The process comprises initially isolating technetium-99m pertechnetate by adsorption upon an adsorbent packing in a chromatographic column. The technetium-99m is then eluted from the packing with a biological compound to form a radiopharmaceutical.

  2. [99mTc(V)-DMSA accumulation in gynecomastia].

    PubMed

    Ohta, H

    1998-11-01

    The accumulation of 99mTc(V)-DMSA in bilateral breasts was recognized in a 60-year-old male with drug-induced gynecomastia. There are some reports describing 99mTc(V)-DMSA accumulation in normal female breast, fibrous dysplasia of the breast and metastatic lesions of breast carcinoma, but to my knowledge, there have been no reports describing 99mTc(V)-DMSA accumulation in gynecomastia.

  3. Novel 99mTc(III)-azide complexes [99mTc(N3)(CDO)(CDOH)2B-R] (CDOH2=cyclohexanedione dioxime) as potential radiotracers for heart imaging.

    PubMed

    Liu, Min; Zheng, Yumin; Avcibasi, Ugur; Liu, Shuang

    2016-11-01

    In this study, novel 99m Tc(III)-azide complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R] ( 99m Tc-ISboroxime-N 3 : R=IS; 99m Tc-MPboroxime-N 3 : R=MP; 99m Tc-PAboroxime-N 3 : R=PA; 99m Tc-PYboroxime-N 3 : R=PY; and 99m Tc-Uboroxime-N 3 : R=5U) were evaluated as heart imaging agents. Complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R] (R=IS, MP, PA, PY and 5U) were prepared by ligand exchange between NaN 3 and [ 99m TcCl(CDO)(CDOH) 2 B-R]. Biodistribution and imaging studies were carried out in Sprague-Dawley rats. Image quantification was performed to compare their initial heart uptake and myocardial retention. 99m Tc-ISboroxime-N 3 , 99m Tc-PYboroxime-N 3 and 99m Tc-Uboroxime-N 3 were prepared with high RCP (93-98%) while the RCP of 99m Tc-MPboroxime-N 3 and 99m Tc-PAboroxime-N 3 was 80-85%. The myocardial retention curves of 99m Tc-ISboroxime-N 3 , 99m Tc-PYboroxime-N 3 and 99m Tc-Uboroxime-N 3 were best fitted to the bi-exponential decay function. The half-time of the fast component was 1.6±0.4min for 99m Tc-ISboroxime-N 3 , 0.7±0.1min for 99m Tc-PYboroxime-N 3 and 0.9±0.4min for 99m Tc-Uboroxime-N 3 . The 2-min heart uptake from biodistribution studies followed the ranking order of 99m Tc-ISboroxime-N 3 (3.60±0.68%ID/g)> 99m Tc-PYboroxime-N 3 (2.35±0.37%ID/g)≫ 99m Tc-Uboroxime-N 3 (1.29±0.06%ID/g). 99m Tc-ISboroxime-N 3 had the highest 2-min heart uptake among 99m Tc radiotracers revaluated in SD rats. High quality SPECT images were obtained with the right and left ventricular walls being clearly delineated. The best image acquisition window was 0-5min for 99m Tc-ISboroxime-N 3 . Both azide coligand and boronate caps had significant impact on the heart uptake and myocardial retention of complexes [ 99m Tc(N 3 )(CDO)(CDOH) 2 B-R]. Among the radiotracers evaluated in SD rats, 99m Tc-ISboroxime-N 3 has the highest initial heart uptake with the heart retention comparable to that of 99m Tc-Teboroxime. 99m Tc-ISboroxime-N 3 is a promising alternative to 99m Tc-Teboroxime for

  4. Tc-99m Labeled carrier for imaging

    DOEpatents

    Henze, Eberhard

    1984-01-01

    Novel radionuclide imaging agents, having particular application for lymphangiography are provided by non-covalently binding Tc-99m to a pharmaceutically acceptable cross-linked polysaccharide. Upon injection of the Tc-99m labeled polysaccharide into the blood stream, optimum contrast can be obtained within one hour.

  5. Early detection of rheumatoid arthritis in rats and humans with 99mTc-3PRGD2 scintigraphy: imaging synovial neoangiogenesis

    PubMed Central

    Wang, Xiangcheng; Zhao, Zhenfang; Wang, Tao; Wang, Xuemei; Li, Xiao-Feng

    2017-01-01

    Objectives: To validate 99mTc-labeled arginylglycylaspartic acid (99mTc-3PRGD2) scintigraphy as a means to image synovial neoangiogenesis in joints afflicted by rheumatoid arthritis and to investigate its potential in the early detection and management of rheumatoid arthritis. Methods: Rheumatoid arthritis and osteoarthritis were generated in Sprague Dawley rats by type II collagen immunization and papain injection, respectively. Rats were imaged with 99mTc-3PRGD2 and 99mTc- methyl diphosphonate (99mTc MDP). X-ray images were also obtained and assessed by a radiologist. Immunohistochemistry of αvβ3 and CD31confirmed the onset of synovial neoangiogenesis. The effect of bevacizumab on rheumatoid arthritis was followed with 99mTc-3PRGD2 scintigraphy. A patient with rheumatoid arthritis and a healthy volunteer were scanned with 99mTc-3PRGD2. Results: Two weeks after immunization, a significant increase in 99mTc-3PRGD2 was observed in the joints of the rheumatoid arthritis model though uptake in osteoarthritis model and untreated controls was low. 99mTc-MDP whole body scans failed to distinguish early rheumatoid arthritis joints from healthy controls. The expression of αvβ3 and CD31was significantly higher in the joints of rheumatoid arthritis rats compared to normal controls. In serial 99mTc-3PRGD2 scintigraphy studies, 99mTc-3PRGD2 uptake increased in parallel with disease progression. Bevacizumab anti-angiogenetic therapy both improved the symptoms of the rheumatoid arthritis rats and significantly decreased 99mTc-3PRGD2 uptake. Significantly higher 99mTc-3PRGD2 accumulation was also observed in rheumatoid arthritis joints in the patient. Conclusions: Our findings indicate that 99mTc-3PRGD2 scintigraphy could detect early rheumatoid arthritis by imaging the associated synovial neoangiogenesis, and may be useful in disease management. PMID:27992368

  6. Tc-99m Ethylenedicysteine and Tc-99m Dimercaptosuccinic Acid Scintigraphy-Comparison of the Two for Detection of Scarring and Differential Cortical Function.

    PubMed

    Dharmalingam, Anitha; Pawar, Shwetal U; Parelkar, Sandesh V; Shetye, Suruchi S; Ghorpade, Mangala K; Tilve, Gundu H

    2017-01-01

    The differential cortical function obtained by Tc-99m EC is comparable to that of Tc-99m DMSA. However, identification of scars on Tc-99m EC images needs to be studied. The aim of the study is to evaluate role of Tc-99m EC for detection of scarring and differential cortical function by comparing with Tc-99m DMSA. Prospective observational study of recurrent UTI; minimum 6 weeks after acute episode; when urine examination is negative for pus cells. Forty-seven children with normal positioned kidneys underwent Tc-99m EC and DMSA scintigraphy. The DRF and cortical phase images of both studies in the same image matrix size were evaluated by two independent observers for scarring; Tc-99m DMSA was considered as the gold standard. MS Excel 2007 and GraphPad Instat V3.1 and ROC analysis. There was no significant difference in the detection of scarring using two studies with Cohen's kappa coefficient (κ) 0.932. The sensitivity and specificity of Tc-99m EC for detection of scarring was 98.75% and 99.15%, respectively. There was good agreement between the differential cortical function calculated using two studies. The summed Tc-99m EC images with an acceptable high image contrast allow detection of cortical scarring in patients with normal kidney positions. It is an excellent single-modality comprehensive investigational agent for renal parenchymal defects, function, and excretion evaluation with the added advantages of lower cost, convenience, and low radiation exposure to the child.

  7. Production and characterization of monoclonal antibodies (mAbs) against human serum albumin (HSA) for the development of an immunoaffinity system with oriented anti-HSA mAbs as immobilized ligand.

    PubMed

    Rajak, Poonam; Vijayalakshmi, M A; Jayaprakash, N S

    2013-05-05

    Proteins present in human serum are of immense importance in the field of biomarker discovery. But, the presence of high-abundant proteins like albumin makes the analysis more challenging because of masking effect on low-abundant proteins. Therefore, removal of albumin using highly specific monoclonal antibodies (mAbs) can potentiate the discovery of low-abundant proteins. In the present study, mAbs against human serum albumin (HSA) were developed and integrated in to an immunoaffinity based system for specific removal of albumin from the serum. Hybridomas were obtained by fusion of Sp2/0 mouse myeloma cells with spleen cells from the mouse immunized with HSA. Five clones (AHSA1-5) producing mAbs specific to HSA were established and characterized by enzyme linked immunosorbent assay (ELISA) and immunoblotting for specificity, sensitivity and affinity in terms of antigen binding. The mAbs were able to bind to both native albumin as well as its glycated isoform. Reactivity of mAbs with different mammalian sera was tested. The affinity constant of the mAbs ranged from 10(8) to 10(9)M(-1). An approach based on oriented immobilization was followed to immobilize purified anti-HSA mAbs on hydrazine activated agarose gel and the dynamic binding capacity of the column was determined. Copyright © 2013 Elsevier B.V. All rights reserved.

  8. Recovery of Technetium Adsorbed on Charcoal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Engelmann, Mark D.; Metz, Lori A.; Ballou, Nathan E.

    2006-05-01

    Two methods capable of near complete recovery of technetium adsorbed on charcoal are presented. The first involves liquid extraction of the technetium from the charcoal by hot 4M nitric acid. An average recovery of 98% (n=3) is obtained after three rounds of extraction. The second method involves dry ashing with air in a quartz combustion tube at 400-450 C. This method yields an average recovery of 96% (n=5). Other thermal methods were attempted, but resulted in reduced recovery and incomplete material balance

  9. Diversification in the Supply Chain of (99)Mo Ensures a Future for (99m)Tc.

    PubMed

    Cutler, Cathy S; Schwarz, Sally W

    2014-07-01

    The uncertain availability of (99m)Tc has become a concern for nuclear medicine departments across the globe. An issue for the United States is that currently it is dependent on a supply of (99m)Tc (from (99)Mo) that is derived solely by production outside the United States. Since the United States uses half the world's (99)Mo production, the U.S. (99)Mo supply chain would be greatly enhanced if a producer were located within the United States. The fragility of the old (99)Mo supply chain is being addressed as new facilities are constructed and new processes are developed to produce (99)Mo without highly enriched uranium. The conversion to low-enriched uranium is necessary to minimize the potential misuse of highly enriched uranium in the world for nonpeaceful means. New production facilities, new methods for the production of (99)Mo, and a new generator elution system for the supply of (99m)Tc are currently being pursued. The progress made in all these areas will be discussed, as they all highlight the need to embrace diversity to ensure that we have a robust and reliable supply of (99m)Tc in the future. © 2014 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

  10. Liver Function in Areas of Hepatic Venous Congestion After Hepatectomy for Liver Cancer: 99mTc-GSA SPECT/CT Fused Imaging Study.

    PubMed

    Yoshida, Morikatsu; Beppu, Toru; Shiraishi, Shinya; Tsuda, Noriko; Sakamoto, Fumi; Kuramoto, Kunitaka; Okabe, Hirohisa; Nitta, Hidetoshi; Imai, Katsunori; Tomiguchi, Seiji; Baba, Hideo; Yamashita, Yasuyuki

    2018-05-01

    Background/Aim: The sacrifice of a major hepatic vein can cause hepatic venous congestion (HVC). We evaluated the effects of HVC on regional liver function using the liver uptake value (LUV), that was calculated from 99m Tc-labeled-galactosyl-human-serum-albumin ( 99m Tc-GSA) single-photon emission computed tomography (SPECT) /contrast-enhanced computed tomography (CE-CT) fused images. Patients and Methods: Sixty-two patients underwent 99m Tc-GSA SPECT/CE-CT prior to hepatectomy for liver cancer and at 7 days after surgery were divided into groups with (n=8) and without HVC (n=54). In the HVC group, CT volume (CTv) and LUV were separately calculated in both congested and non-congested areas. Results: The remnant LUV/CTv of the HVC group was significantly smaller than that of the non-HVC group (p<0.01). The mean functional ratio was 0.47±0.05, and all ratios were ≥0.39. Conclusion: After hepatectomy with sacrifice of major hepatic vein, liver function per unit volume in the congested areas was approximately 40% of that in the non-congested areas. Copyright© 2018, International Institute of Anticancer Research (Dr. George J. Delinasios), All rights reserved.

  11. The adsorption of 99Tcm dimercaptosuccinic acid onto injection vials.

    PubMed

    Millar, A M

    1984-04-01

    It is common practice to dispense radiopharmaceuticals into empty sterile vials for dispatch to the departments where they are to be administered. It has been noted that on withdrawal of technetium-99m dimercaptosuccinic acid injections (99Tcm-DMSA) which have been dispensed into such vials, the activities obtained are lower than expected. To explain this phenomenon, the adsorption of 99Tcm-DMSA onto commercially available, empty, sterile vials has been investigated. The 99Tcm-DMSA solutions were prepared using kits from two manufacturers and were tested in vials from two manufacturers and the original kit vials. Adsorption of 99Tcm in one DMSA/vial combination after storage for 4 h was 49.6% (+/- 4.5% S.E.M.), but typically, adsorption was approximately 12% after 4 h. Although rate of adsorption was found to vary with storage conditions, no conditions satisfactorily overcame the effect. In vials from one manufacturer, the 99Tcm adsorption was predominantly on the glass, while in vials from the other, it was predominantly on the rubber stopper. It is concluded that the compatibility between vials and radiopharmaceuticals must be investigated in the hospital radiopharmacy.

  12. Exploring the Potential of (99m)Tc(CO)3-Labeled Triazolyl Peptides for Tumor Diagnosis.

    PubMed

    Gaonkar, Raghuvir H; Ganguly, Soumya; Baishya, Rinku; Dewanjee, Saikat; Sinha, Samarendu; Gupta, Amit; Ganguly, Shantanu; Debnath, Mita C

    2016-04-01

    In recent years the authors have reported on (99m)Tc(CO)3-labeled peptides that serve as carriers for biomolecules or radiopharmaceuticals to the tumors. In continuation of that work they report the synthesis of a pentapeptide (Met-Phe-Phe-Gly-His; pep-1), a hexapeptide (Met-Phe-Phe-Asp-Gly-His; pep-2), and a tetrapeptide (Asp-Gly-Arg-His; pep-3) and the attachment of 3-amino-1,2,4-triazole to the β carboxylic function of the aspartic acid unit of pep-2 and pep-3. The pharmacophores were radiolabeled in high yields with [(99m)Tc(CO)3(H2O)3](+) metal aqua ion, characterized for their stability in serum and saline, as well as in His solution, and found to be substantially stable. B16F10 cell line binding studies showed favorable uptake and internalization. In vivo behavior of the radiolabeled triazolyl peptides was assessed in mice bearing induced tumor. The (99m)Tc(CO)3-triazolyl pep-3 demonstrated rapid urinary clearance and comparatively better tumor uptake. Imaging studies showed visualization of the tumor using (99m)Tc(CO)3-triazolyl pep-3, but due to high abdominal background, low delineation occurred. Based on the results further experiments will be carried out for targeting tumor with triazolyl peptides.

  13. A preliminary study of imaging paclitaxel-induced tumor apoptosis with (99)Tc(m)-His10-Annexin V.

    PubMed

    Zheng, Yu-min; Wang, Feng; Fang, Wei; Hua, Zi-chun; Wang, Zi-zheng; Meng, Qing-le; Yan, Jue

    2013-01-01

    In tumors the process of apoptosis occurs over an interval of time after chemotherapy. It is important to determine the best time for detecting apoptosis by in vivo imaging. In this study, we evaluated the dynamics and feasibility of imaging non-small cell lung cancer (NSCLC) apoptosis induced by paclitaxel treatment using a (99)Tc(m)-labeled Annexin V recombinant with ten consecutive histidines (His10-Annexin V) in a mouse model. (99)Tc(m)-His10-Annexin V was prepared by one step direct labeling; radio-chemical purity (RCP) and radio-stability was tested. The binding of (99)Tc(m)-His10-Annexin V to apoptotic cells was validated in vitro using camptothecin-induced Jurkat cells. In vivo bio-distribution was determined in mice by dissection. The human H460 NSCLC tumor cell line (H460) tumor-bearing mice were treated with intravenous paclitaxel 24, 48 and 72 hours later. (99)Tc(m)-His10-Annexin V was injected intravenously, and planar images were acquired at 2, 4 and 6 hours post-injection on a dual-head gamma camera fitted with a pinhole collimator. Tumor-to-normal tissue ratios (T/NT) were calculated by ROI analysis and they reflected specific binding of (99)Tc(m)-His10-Annexin V. Mice were sacrificed after imaging. Caspase-3, as the apoptosis detector, was determined by flow cytometry, and DNA fragmentation was analyzed by the terminal deoxynucleotidytransferase mediated dUTP nick-end labeling (TUNEL) assay. Nonspecific accumulation of protein was estimated using bovine serum albumin (BSA). The imaging data were correlated with TUNEL-positive nuclei and caspase-3 activity. (99)Tc(m)-His10-Annexin V had a RCP > 98% and high stability 2 hours after radio-labeling, and it could bind to apoptotic cells with high affinity. Bio-distribution of (99)Tc(m)-His10-Annexin V showed predominant uptake in kidney, relatively low uptake in myocardium, liver and gastrointestinal tract, and rapid clearance from blood and kidney was observed. The T/NT was significantly increased

  14. Monitoring Tc dynamics in a bioreduced sediment: an investigation with gamma camera imaging of (99m)Tc-pertechnetate and (99m)Tc-DTPA.

    PubMed

    Vandehey, Nicholas T; O'Neil, James P; Slowey, Aaron J; Boutchko, Rostyslav; Druhan, Jennifer L; Moses, William W; Nico, Peter S

    2012-11-20

    We demonstrate the utility of nuclear medical imaging technologies and a readily available radiotracer, [(99m)Tc]TcO(4)(-), for the noninvasive monitoring of Fe(II) production in acetate-stimulated sediments from Old Rifle, CO, USA. Microcosms consisting of sediment in artificial groundwater media amended with acetate were probed by repeated injection of radiotracer over three weeks. Gamma camera imaging was used to noninvasively quantify the rate and extent of [(99m)Tc]TcO(4)(-) partitioning from solution to sediment. Aqueous Fe(II) and sediment-associated Fe(II) were also measured and correlated with the observed tracer behavior. For each injection of tracer, curves of (99m)Tc concentration in solution vs time were fitted to an analytic function that accounts for both the observed rate of sedimentation as well as the rate of (99m)Tc association with the sediment. The rate and extent of (99m)Tc association with the biostimulated sediment correlated well with the production of Fe(II), and a mechanism of [(99m)Tc]TcO(4)(-) reduction via reaction with surface-bound Fe(II) to form an immobile Tc(IV) species was inferred. After three weeks of bioreduction, a subset of microcosms was aerated in order to reoxidize the Fe(II) to Fe(III), which also destroyed the affinity of the [(99m)Tc]TcO(4)(-) for the sediments. However, within 3 days postoxidation, the rate of Tc(VII) reduction was faster than immediately before oxidation implying a rapid return to more extensive bioreduction. Furthermore, aeration soon after a tracer injection showed that sediment-bound Tc(IV) is rapidly resolubilized to Tc(VII). In contrast to the [(99m)Tc]TcO(4)(-), a second commercially available tracer, (99m)Tc-DTPA (diethylenetriaminepentaacetic acid), had minimal association with sediment in both controls and biostimulated sediments. These experiments show the promise of [(99m)Tc]TcO(4)(-) and (99m)Tc-DTPA as noninvasive imaging probes for a redox-sensitive radiotracer and a conservative flow

  15. Oxidative metabolism of BDE-99 by human liver microsomes: predominant role of CYP2B6.

    PubMed

    Erratico, Claudio A; Szeitz, András; Bandiera, Stelvio M

    2012-10-01

    Hydroxylated polybrominated diphenyl ethers (PBDEs) have been found in human serum, suggesting that they are formed by in vivo oxidative metabolism of PBDEs. However, the biotransformation of 2,2',4,4',5-pentabromodiphenyl ether (BDE-99), a major PBDE detected in human tissue and environmental samples, is poorly understood. In the present study, the oxidative metabolism of BDE-99 was assessed using pooled and single-donor human liver microsomes, a panel of human recombinant cytochrome P450 (CYP) enzymes, and CYP-specific antibodies. Hydroxylated metabolites were quantified using a liquid chromatography/tandem mass spectrometry-based method. In total, 10 hydroxylated metabolites of BDE-99 were produced by human liver microsomes. Six metabolites were identified as 2,4,5-tribromophenol (2,4,5-TBP), 4-OH-BDE-90, 5'-OH-BDE-99, 6'-OH-BDE-99, 4'-OH-BDE-101, and 2-OH-BDE-123 using authentic standards. Three monohydroxy- and one dihydroxy-pentabrominated metabolites were unidentified. Rates of formation of the three major metabolites (2,4,5-TBP, 5'-OH-BDE-99, and 4'-OH-BDE-101) by human liver microsomes ranged from 24.4 to 44.8 pmol/min/mg protein. Additional experiments demonstrated that the dihydroxylated metabolite was a primary metabolite of BDE-99 and was not produced by hydroxylation of a monohydroxy metabolite. Among the panel of recombinant CYP enzymes tested, formation of all 10 hydroxylated metabolites was catalyzed solely by CYP2B6. A combined approach using antibodies to CYP2B6 and single-donor liver microsomes expressing a wide range of CYP2B6 levels confirmed that CYP2B6 was responsible for the biotransformation of BDE-99. Collectively, the results show that the oxidative metabolism of BDE-99 by human liver microsomes is catalyzed solely by CYP2B6 and is an important determinant of the toxicity and bioaccumulation of BDE-99 in humans.

  16. Tellurite glasses for vitrification of technetium-99 from pyrochemical processing

    NASA Astrophysics Data System (ADS)

    Pyo, Jae-Young; Lee, Cheong Won; Park, Hwan-Seo; Yang, Jae Hwan; Um, Wooyong; Heo, Jong

    2017-09-01

    A new alkali-alumino tellurite glass composition was developed to immobilize highly-volatile technetium (Tc) wastes generated from the pyrochemical processing technology. Tellurite glass can incorporate up to 7 mass% of rhenium (Re, used as a surrogate for Tc) with an average retention of 86%. Normalized elemental releases evaluated by seven-day product consistency test (PCT) satisfied the immobilized low activity waste requirements of United States when concentration of Ca(ReO4)2 in the glass was <12 mass%. Re ions form Re7+ and are coordinated with four oxygens to form ReO4- tetrahedra. These tetrahedra bond to modifiers such as Ca2+ or Na+ that are further connected to the tellurite glass network by Ca2+ (or Na+) - non-bridging oxygen bonds.

  17. Development of a Radiolabeled Amlodipine Analog for L-type Calcium Channel Imaging.

    PubMed

    Firouzyar, Tahereh; Jalilian, Amir Reza; Aboudzadeh, Mohammad Reza; Sadeghpour, Hossein; Pooladi, Mehrban; Shafiee-Ardestani, Mahdi; Khalaj, Ali

    2017-01-01

    The non-invasive imaging and quantification of L-type calcium channels (also known as dihydropyridine channels) in living tissues is of great interest in diagnosis of congestive heart failure, myocardial hypertrophy, irritable bowel syndrome etc. Technetium-99m labeled amlodipine conjugate ([99mTc]-DTPA-AMLO) was prepared starting freshly eluted (<1 h) 99mTechnetium pertechnetate (86.5 MBq) and conjugated DTPAAMLO at pH 5 in 30 min at room temperature in high radiochemical purity (>99%, RTLC; specific activity: 55-60 GBq/mmol). The calcium channel blockade activity (CCBA) and apoptosis/necrosis assay of DTPA-amlodipine conjugate evaluations were performed for the conjugate. Log P, stability, bio-distribution and imaging studies were performed for the tracer followed by biodistribution studies as well as imaging. The conjugate demonstrated low toxicity on MCF-7 cells and CCBA (at µm level) compared to the amlodipine. The tracer was stable up to 4 h in final production and presence of human serum and log P (-0.49) was consistent with a water soluble complex. The tracer was excreted through kidneys and liver as expected for dihydropyridines; excluding excretory organs, calcium channel rich smooth muscle cells; including colon, intestine and lungs which demonstrated significant uptake. SPECT images supported the bio-distribution data up to 4 h. significant uptake of [99mTc]-DTPA-AMLO was obtained in calcium channel rich organs. The complex can be a candidate for further SPECT imaging for L-type calcium channels. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  18. Use of {sup 99m}Tc 2-methoxyisobutyl isonitrile in minimally invasive radioguided surgery in patients with primary hyperparathyroidism: A narrative review of the current literature

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Denmeade, Kristie A; Constable, Chris; Reed, Warren M

    The use of technetium-99m 2-methoxyisobutyl isonitrile ({sup 99m}Tc MIBI) for assistance in minimally invasive radioguided surgery (MIRS) is growing in popularity as a safe, effective, and proficient technique used for parathyroidectomy in primary hyperparathyroidism (PHPT) treatment. Previously, the preferred treatment for PHPT was bilateral neck exploration (BNE), a very invasive, costly, and lengthy procedure. However, as a large majority (80–85% of cases of PHPT) are attributed to a single parathyroid adenoma (PA), a simpler more direct technique such as MIRS is a far better option. The following article is an exploration of the current literature concerning varied protocols utilizing {supmore » 99m}Tc MIBI for assistance in MIRS for patients undergoing treatment of PHPT. This technique boasts many advantageous outcomes for patients suffering from PHPT. These include a reduction in cost, operating time, and patient recovery; less evidence of post-surgical hypocalcaemia, less pain, and complications; superior cosmetic results; same-day discharge; and the possibility of local anaesthesia which is particularly beneficial in elderly patients. Better outcomes for patients with deep or ectopic PAs, reduced intra-operative complications, and improved cosmetic outcomes for patients who have previously undergone thyroid and/or parathyroid surgery are also advantageous. Of the literature reviewed it was also found that no patients suffered any major surgical complications such as laryngeal nerve palsy or permanent hypoparathyroidism using {sup 99m}Tc MIBI for assistance in MIRS.« less

  19. Absorbed radiation dose in adults from iodine-131 and iodine-123 orthoiodohippurate and technetium-99m DTPA renography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlsen, O.

    1988-03-01

    A mathematic model for evaluation of absorbed dose in radionuclide renography has been developed and programmed for automatic calculation in the computer. Input data to the model are readily available from the results of the renography and, hence, the method described is suitable for individual dose determinations in adults. Apart from the situation with very considerable outflow obstructions (/sup 131/I)OIH single probe renography involves a 15-20 times smaller dose to radiation sensitive organs than (/sup 123/I)OIH gamma camera renography. Further, the latter examination results in a 2-10 times smaller dose than (/sup 99m/Tc)DTPA gamma camera renography under normal outflow conditions.more » Absorbed renal dose is large, approximately 70 mGy, in the three renographies in the borderline case with total outflow obstructions. For comparison, i.v. pyelography, which is the x-ray examination often used instead of radionuclide renography, involves an absorbed dose to ovaries 10-1000 times larger than in radionuclide renography« less

  20. Effective detection of the tumors causing osteomalacia using [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body scan.

    PubMed

    Jing, Hongli; Li, Fang; Zhuang, Hongming; Wang, Zhenghua; Tian, Jian; Xing, Xiaoping; Jin, Jin; Zhong, Dingrong; Zhang, Jingjing

    2013-11-01

    Tumor-induced osteomalacia (TIO) is an endocrine disorder caused by tumors producing excessive fibroblast growth factor-23 (FGF-23). The causative tumors are generally small, slow-growing benign mesenchymal tumors. The only cure of the disease depends on resection of the tumors, which are extremely difficult to localize due to their small sizes and rare locations. Since these tumors are known to express somatostatin receptors, this research was undertaken to evaluate efficacy of [Tc-99m]-HYNIC-octreotide (99mTc-HYNIC-TOC) whole body imaging in this clinical setting Images of 99mTc-HYNIC-TOC scans and clinical chart from 183 patients with hypophosphatemia and clinically suspected TIO were retrospectively reviewed. The scan findings were compared to the results of histopathological examinations and clinical follow-ups. Among 183 patients, 72 were confirmed to have TIO while 103 patients were found to have other causes of hypophosphatemia. The possibility of TIO could not be either diagnosed or excluded in the remaining 8 patients. For analytical purposes, these 8 patients who could neither be diagnosed nor excluded as having TIO were regarded as having the disease, bringing the total of TIO patients to 80. The 99mTc-HYNIC-TOC scan identified 69 tumors in 80 patients with TIO, which rendered a sensitivity of 86.3% (69/80). 99mTc-HYNIC-TOC scintigraphy excluded 102 patients without TIO with a specificity of 99.1% (102/103). The overall accuracy of 99mTc-HYNIC-TOC whole body scan in the localization of tumors responsible for osteomalacia is 93.4% (171/183). Whole body 99mTc-HYNIC-TOC imaging is effective in the localization of occult tumors causing TIO. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  1. Technetium Getters to Improve Cast Stone Performance

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Neeway, James J.; Lawter, Amanda R.; Serne, R. Jeffrey

    2015-10-15

    The cementitious material known as Cast Stone has been selected as the preferred waste form for solidification of aqueous secondary liquid effluents from the Hanford Tank Waste Treatment and Immobilization Plant (WTP) process condensates and low-activity waste (LAW) melter off-gas caustic scrubber effluents. Cast Stone is also being evaluated as a supplemental immobilization technology to provide the necessary LAW treatment capacity to complete the Hanford tank waste cleanup mission in a timely and cost effective manner. Two radionuclides of particular concern in these waste streams are technetium-99 (99Tc) and iodine-129 (129I). These radioactive tank waste components contribute the most tomore » the environmental impacts associated with the cleanup of the Hanford site. A recent environmental assessment of Cast Stone performance, which assumes a diffusion controlled release of contaminants from the waste form, calculates groundwater in excess of the allowable maximum permissible concentrations for both contaminants. There is, therefore, a need and an opportunity to improve the retention of both 99Tc and 129I in Cast Stone. One method to improve the performance of Cast Stone is through the addition of “getters” that selectively sequester Tc and I, therefore reducing their diffusion out of Cast Stone. In this paper, we present results of Tc and I removal from solution with various getters with batch sorption experiments conducted in deionized water (DIW) and a highly caustic 7.8 M Na Ave LAW simulant. In general, the data show that the selected getters are effective in DIW but their performance is comprised when experiments are performed with the 7.8 M Na Ave LAW simulant. Reasons for the mitigated performance in the LAW simulant may be due to competition with Cr present in the 7.8 M Na Ave LAW simulant and to a pH effect.« less

  2. RHENIUM SOLUBILITY IN BOROSILICATE NUCLEAR WASTE GLASS IMPLICATIONS FOR THE PROCESSING AND IMMOBILIZATION OF TECHNETIUM-99 (AND SUPPORTING INFORMATION WITH GRAPHICAL ABSTRACT)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    AA KRUGER; A GOEL; CP RODRIGUEZ

    2012-08-13

    The immobilization of 99Tc in a suitable host matrix has proved a challenging task for researchers in the nuclear waste community around the world. At the Hanford site in Washington State in the U.S., the total amount of 99Tc in low-activity waste (LAW) is {approx} 1,300 kg and the current strategy is to immobilize the 99Tc in borosilicate glass with vitrification. In this context, the present article reports on the solubility and retention of rhenium, a nonradioactive surrogate for 99Tc, in a LAW sodium borosilicate glass. Due to the radioactive nature of technetium, rhenium was chosen as a simulant becausemore » of previously established similarities in ionic radii and other chemical aspects. The glasses containing target Re concentrations varying from 0 to10,000 ppm by mass were synthesized in vacuum-sealed quartz ampoules to minimize the loss of Re by volatilization during melting at 1000 DC. The rhenium was found to be present predominantly as Re7 + in all the glasses as observed by X-ray absorption near-edge structure (XANES). The solubility of Re in borosilicate glasses was determined to be {approx}3,000 ppm (by mass) using inductively coupled plasma-optical emission spectroscopy (ICP-OES). At higher rhenium concentrations, some additional material was retained in the glasses in the form of alkali perrhenate crystalline inclusions detected by X-ray diffraction (XRD) and laser ablation-ICP mass spectrometry (LA-ICP-MS). Assuming justifiably substantial similarities between Re7 + and Tc 7+ behavior in this glass system, these results implied that the processing and immobilization of 99Tc from radioactive wastes should not be limited by the solubility of 99Tc in borosilicate LAW glasses.« less

  3. Photoreduction of 99Tc Pertechnetate by Nanometer-Sized Metal Oxides: New Strategies for Formation and Sequestration of Low-Valent Technetium

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Burton-Pye, Benjamin P.; Radivojevic, Ivana; McGregor, Donna

    2011-11-23

    Technetium-99 ( 99Tc)(β - max: 293.7 keV; t 1/2: 2.1 x 10 5 years) is a byproduct of uranium-235 fission and comprises a large component of radioactive waste. Under aerobic conditions and in a neutral- basic environment, the pertechnetate anion ( 99TcO 4 -) is stable. 99TcO 4 - is very soluble, migrates easily through the environment and does not sorb well onto mineral surfaces, soils or sediments. This study moves forward a new strategy for the reduction of TcO 4 - and chemical incorporation of the reduced 99Tc into a metal oxide material. This strategy employs a single material,more » a polyoxometalate (POM), α 2-[P 2W 17O 61] 10-, that can be photoactivated in the presence of 2-propanol to transfer electrons to TcO 4 - and incorporate the reduced 99Tc covalently into the α 2 - framework to form the Tc VO species, Tc VO(α 2-P 2W 17O 61) 7-. This occurs via the formation of an intermediate species that slowly converts to Tc VO(α 2-P 2W 17O 61) 7-. EXAFS and XANES analysis and preliminary EPR analysis, suggests that the intermediate consists of a Tc(IV) α 2- species where the 99Tc is likely bound to only 2 of the 4 W-O oxygen atoms in the α 2-[P 2W 17O 61] 10- defect. This intermediate then oxidizes and converts to the 99Tc VO(α 2-P 2W 17O 61) 7- product. The reduction and incorporation of 99TcO 4- was accomplished in a ''one pot'' reaction using both sunlight and UV irradiation, and monitored as a function of time using multinuclear NMR and radio TLC. The process was further probed by the ''step-wise'' generation of reduced α 2-P 2W 17O 61 12- through bulk electrolysis followed by the addition of TcO 4 -. The reduction and incorporation of ReO 4 -, as a non-radioactive surrogate for 99Tc, does not proceed through the intermediate species, and Re VO is incorporated quickly into the α 2-[P 2W 17O 61] 10- defect. These observations are consistent with the periodic trends of 99Tc and Re. Specifically, 99Tc is more easily reduced compared to Re. In addition

  4. Serum from pregnant women with gestational diabetes mellitus increases the expression of FABP4 mRNA in primary subcutaneous human pre-adipocytes

    PubMed Central

    Li, Lan; Lee, Se Jin; Kook, Song Yi; Ahn, Tae Gyu; Lee, Ji Yeon

    2017-01-01

    Objective Gestational diabetes mellitus (GDM) is defined as glucose intolerance first detected during pregnancy. It can result in pregnancy complications such as birth injury, stillbirth. Fatty acid-binding protein 4 (FABP4), found in adipose tissue, is associated with insulin resistance, and type 2 diabetes. The aim of this study was to investigate whether FABP4 in the placenta and decidua of pregnant women with GDM is higher than that in normal pregnant women, and whether serum from pregnant women with GDM may cause adipocytes to secrete more FABP4 than does serum from a normal pregnant group. Methods We obtained placentas, deciduas, and serum from 12 pregnant women with GDM and 12 normal pregnant women and performed enzyme-linked immunosorbent assay, real time quantitative-polymerase chain reaction. We cultured human pre-adipocytes for 17 days with GDM and non-GDM serum and performed western blot, real time quantitative-polymerase chain reaction, and oil red O staining. Results Expression of FABP4 in serum, placenta and decidua of pregnant women with GDM was significantly higher than that in normal pregnant women. Serum from pregnant women with GDM increased the expression of FABP4 mRNA and decreased the expression of adiponectin mRNA in human pre-adipocytes significantly. Adipocyte cultured in GDM serum showed significantly greater lipid accumulation than those cultured in normal serum. Conclusion Our results suggest that FABP4 is higher in placenta and decidua from pregnant women with GDM. Increased circulating FABP4 in maternal serum from pregnant women with GDM may originate from adipocytes and the placenta. Circulating FABP4 can induce increased insulin resistance and decreased insulin sensitivity. PMID:28534013

  5. Serum from pregnant women with gestational diabetes mellitus increases the expression of FABP4 mRNA in primary subcutaneous human pre-adipocytes.

    PubMed

    Li, Lan; Lee, Se Jin; Kook, Song Yi; Ahn, Tae Gyu; Lee, Ji Yeon; Hwang, Jong Yun

    2017-05-01

    Gestational diabetes mellitus (GDM) is defined as glucose intolerance first detected during pregnancy. It can result in pregnancy complications such as birth injury, stillbirth. Fatty acid-binding protein 4 (FABP4), found in adipose tissue, is associated with insulin resistance, and type 2 diabetes. The aim of this study was to investigate whether FABP4 in the placenta and decidua of pregnant women with GDM is higher than that in normal pregnant women, and whether serum from pregnant women with GDM may cause adipocytes to secrete more FABP4 than does serum from a normal pregnant group. We obtained placentas, deciduas, and serum from 12 pregnant women with GDM and 12 normal pregnant women and performed enzyme-linked immunosorbent assay, real time quantitative-polymerase chain reaction. We cultured human pre-adipocytes for 17 days with GDM and non-GDM serum and performed western blot, real time quantitative-polymerase chain reaction, and oil red O staining. Expression of FABP4 in serum, placenta and decidua of pregnant women with GDM was significantly higher than that in normal pregnant women. Serum from pregnant women with GDM increased the expression of FABP4 mRNA and decreased the expression of adiponectin mRNA in human pre-adipocytes significantly. Adipocyte cultured in GDM serum showed significantly greater lipid accumulation than those cultured in normal serum. Our results suggest that FABP4 is higher in placenta and decidua from pregnant women with GDM. Increased circulating FABP4 in maternal serum from pregnant women with GDM may originate from adipocytes and the placenta. Circulating FABP4 can induce increased insulin resistance and decreased insulin sensitivity.

  6. Tc-99m Glu-Cys-Gly-His-Gly-Lys (ECG-HGK), a novel Tc-99m labeled hexapeptide for molecular tumor imaging.

    PubMed

    Kim, Dae-Weung; Kim, Myoung Hyoun; Kim, Chang Guhn

    2016-03-01

    Domain 5 of kinin-free high molecular weight kininogen inhibits the adhesion of many tumor cell lines, and it has been reported that the histidine-glycine-lysine (HGK)-rich region might be responsible for inhibition of cell adhesion. The authors developed HGK-containing hexapeptide, glutamic acid-cysteine-glycine (ECG)-HGK, and evaluated the utility of Tc-99m ECG-HGK for tumor imaging. Hexapeptide, ECG-HGK was synthesized using Fmoc solid-phase peptide synthesis. Radiolabeling efficiency was evaluated. The uptake of Tc-99m ECG-HGK within HT-1080 cells was evaluated in vitro. In HT-1080 tumor-bearing mice, gamma imaging and biodistribution studies were performed. The complexes Tc-99m ECG-HGK was prepared in high yield. The uptake of Tc-99m ECG-HGK within the HT-1080 tumor cells had been demonstrated by in vitro studies. The gamma camera imaging in the murine model showed that Tc-99m ECG-HGK was accumulated substantially in the HT-1080 tumor (tumor-to-muscle ratio = 5.7 ± 1.4 at 4 h), and the tumoral uptake was blocked by the co-injection of excess HGK (tumor-to-muscle ratio = 2.8 ± 0.6 at 4 h). In the present study, Tc-99m ECG-HGK was developed as a new tumor imaging agents. Our in vitro and in vivo studies revealed specific function of Tc-99m ECG-HGK for tumor imaging. Copyright © 2016 John Wiley & Sons, Ltd.

  7. Kit preparation and biokinetics in women of 99mTc-EDDA/HYNIC-E-[c(RGDfK)]2 for breast cancer imaging.

    PubMed

    Ortiz-Arzate, Zareth; Santos-Cuevas, Clara L; Ocampo-García, Blanca E; Ferro-Flores, Guillermina; García-Becerra, Rocío; Estrada, Gisela; Gómez-Argumosa, Edgar; Izquierdo-Sánchez, Vanessa

    2014-04-01

    In breast cancer, α(ν)β(3) and/or α(ν)β(5) integrins are overexpressed in both endothelial and tumour cells. Radiolabelled peptides based on the Arg-Gly-Asp (RGD) sequence are radiopharmaceuticals with high affinity and selectivity for these integrins. The RGD-dimer peptide (E-[c(RGDfK)]2) radiolabelled with (99m)Tc has been reported as a radiopharmaceutical with a 10-fold higher affinity for the α(ν)β(3) integrin compared with the RGD-monomer. Ethylenediamine-N,N'-diacetic acid (EDDA) is a hydrophilic molecule that may favour renal excretion when used as coligand in the (99m)Tc labelling of hydrazinonicotinamide (HYNIC) peptides and can easily be formulated in a lyophilized kit. The aim of this study was to establish a biokinetic model for (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 prepared from lyophilized kits and evaluate its dosimetry as a tumour-imaging agent in seven healthy women and three breast cancer patients. (99m)Tc labelling was performed by adding sodium pertechnetate solution and 0.2 mol/l phosphate buffer (pH 7.0) to a lyophilized formulation containing E-[c(RGDfK)]2, EDDA, tricine, mannitol and stannous chloride. The radiochemical purity was evaluated using reverse-phase high-performance liquid chromatography and instant thin-layer chromatography on silica gel analyses. Stability studies in human serum were carried out using size-exclusion high-performance liquid chromatography. In-vitro cell uptake was tested using breast cancer cells (MCF7, T47D and MDA-MB-231) with blocked and nonblocked receptors. Biodistribution and tumour uptake were determined in MCF7 tumour-bearing nude mice with blocked and nonblocked receptors, and images were obtained using a micro-SPECT/PET/CT. Whole-body images from seven healthy women were acquired at 0.5, 1, 3, 6 and 24 h after (99m)Tc-EDDA/HYNIC-E-[c(RGDfK)]2 administration with radiochemical purities greater than 94%. Regions of interest were drawn around the source organs at each time frame. Each region of

  8. Normal regional distribution of cerebral blood flow in dogs: comparison between (99m) Tc-ethylcysteinate dimer and (99m) Tc- hexamethylpropylene amine oxime single photon emission computed tomography.

    PubMed

    Adriaens, Antita; Polis, Ingeborgh; Waelbers, Tim; Vandermeulen, Eva; Dobbeleir, André; De Spiegeleer, Bart; Peremans, Kathelijne

    2013-01-01

    Functional imaging provides important insights into canine brain pathologies such as behavioral problems. Two (99m) Tc-labeled single photon emission computed tomography (SPECT) cerebral blood flow tracers-ethylcysteinate dimer (ECD) and hexamethylpropylene amine oxime (HMPAO)-are commonly used in human medicine and have been used previously in dogs but intrasubject comparison of both tracers in dogs is lacking. Therefore, this study investigated whether regional distribution differences between both tracers occur in dogs as is reported in humans. Eight beagles underwent two SPECT examinations first with (99m) Tc-ECD and followed by (99m) Tc-HMPAO. SPECT scanning was performed with a triple head gamma camera equipped with ultrahigh resolution parallel hole collimators. Images were reconstructed using filtered backprojection with a Butterworth filter. Emission data were fitted to a template permitting semiquantification using predefined regions or volumes of interest (VOIs). For each VOI, perfusion indices were calculated by normalizing the regional counts per voxel to total brain counts per voxel. The obtained perfusion indices for each region for both tracers were compared with a paired Student's T-test. Significant (P < 0.05) regional differences were seen in the subcortical region and the cerebellum. Both tracers can be used to visualize regional cerebral blood flow in dogs, however, due to the observed regional differences, they are not entirely interchangeable. © 2013 Veterinary Radiology & Ultrasound.

  9. Improvement of Cerebral Hypoperfusion with Levothyroxine Therapy in Hashimoto's Encephalopathy Demonstrated by 99mTc-HMPAO-SPECT

    PubMed Central

    Schnedl, Wolfgang J.; Mirzaei, Siroos; Wallner-Liebmann, Sandra J.; Tafeit, Erwin; Mangge, Harald; Krause, Robert; Lipp, Rainer W.

    2013-01-01

    Background Hashimoto's encephalopathy (HE) is a rare immune-mediated encephalopathy associated with autoimmune Hashimoto's thyroiditis. Objectives and Methods We report on a patient with HE and significant clinical improvement correlating with an increase in cerebral blood flow demonstrated by hexamethylpropyleneamine oxime (HMPAO) single-photon emission computed tomography (SPECT). HMPAO-SPECT was performed with 740 MBq of technetium-99m-HMPAO. To demonstrate the improvement in regional cerebral blood flow, individual regions of interest were drawn around visually diminished HMPAO uptake, the lesion to reference region ratio was calculated and transverse section images and semi-quantitative measurements were performed. Results We show a 5-year follow-up with significant clinical improvement, a 10-fold reduction in autoantibodies to thyroid peroxidase and an approximately 20% improvement in cerebral blood flow with HMPAO-SPECT. Conclusion Adequate levothyroxine treatment achieving and maintaining euthyroidism should be considered as therapy to lower autoantibodies and improve clinical outcome in patients with Hashimoto's thyroiditis and encephalopathy. PMID:24783049

  10. Quantitative studies of bone using (18)F-fluoride and (99m)Tc-methylene diphosphonate: evaluation of renal and whole-blood kinetics.

    PubMed

    Park-Holohan, S J; Blake, G M; Fogelman, I

    2001-09-01

    We report a study of the renal and whole-blood kinetics of (18)F-fluoride and (99m)Tc-methylene diphosphonate ((99m)Tc-MDP) and their effect on the evaluation of the skeletal kinetics of the two bone tracers. Data were obtained during an investigation of postmenopausal women taking hormone replacement therapy who were compared with untreated, age-matched controls. After intravenous injection of 18F-fluoride (1 MBq), (99m)Tc-MDP (1 MBq), (51)Cr-ethylenediaminetetraacetic acid (51Cr-EDTA) (3 MBq) and (125)I-human serum albumin ((125)I-HSA) (0.25 MBq), multiple blood samples and urine collections were taken between 0 and 4 h after injection. (51)Cr-EDTA data were used to evaluate the glomerular filtration rate (GFR) and the completeness of each timed urine collection. (125)I-HSA data were used to evaluate the plasma volume and the red cell uptake of the other three tracers. At 4 h, the cumulative urine excretions (and standard deviations, SDs) were: (99m)Tc-MDP, 58.2% (4.8%); (18)F-fluoride, 36.1% (5.7%); (51)Cr-EDTA, 81.5% (4.5%). Plots of the renal clearance of (18)F-fluoride against urine volume showed that urine flow rates greater than 5 ml.min-1 were necessary to ensure a constant renal clearance of (18)F and hence stable conditions for the evaluation of bone tracer kinetics. In contrast, a low urine flow rate had no effect on the renal kinetics of (99m)Tc-MDP. For MDP, the evaluation of skeletal kinetics requires data on protein binding so that calculations can be performed for free MDP. In the present study, protein binding of MDP was evaluated from the ratio of total (99m)Tc-MDP renal clearance to GFR based on the principle that free (99m)Tc-MDP is a GFR tracer. Between 0 and 4 h after injection, the fractional protein binding of MDP increased linearly with time, changing from 21+/-5% immediately after injection to 58+/-5% at 4 h. Although red cell uptake of (99m)Tc-MDP was negligible, for (18)F-fluoride around 30% of circulating tracer was transported in red

  11. Structural consistency analysis of recombinant and wild-type human serum albumin

    NASA Astrophysics Data System (ADS)

    Cao, Hui-Ling; Sun, Li-Hua; Liu, Li; Li, Jian; Tang, Lin; Guo, Yun-Zhu; Mei, Qi-Bing; He, Jian-Hua; Yin, Da-Chuan

    2017-01-01

    Recombinant human serum albumin (rHSA) is potential alternatives for human serum albumin (HSA) which may ease severe shortage of HSA worldwide. In theory, rHSA and HSA are the same. Structure decides function. Therefore, the 3D structural consistency analysis of rHSA and HSA is outmost importance, which is the base of their function consistency. In this paper, the crystal structures of rHSA at resolution limit of 2.22 Å and HSA at 2.30 Å were determined by X-ray diffraction (XRD), which were deposited in the Protein Data Bank (PDB) with accession codes 4G03 (rHSA) and 4G04 (HSA). The differences between rHSA and HSA were systematically analyzed from the crystallization behavior, diffraction data and three-dimensional (3D) structure. The superimposed contrasted analysis indicated that rHSA and HSA achieved a structural similarity of 99% with an r.m.s. deviation of 0.397 Å for the corresponding overall Cα atoms. In addition, the number of α-helices in the rHSA or HSA molecule was verified to be 30. As a result, rHSA can potentially replace HSA. The study provides a theoretical and experimental basis for the clinical and additional applications of rHSA. Meanwhile, it is also a good example for applications of genetic engineering.

  12. Macrocyclic triamine derived glucose analogues for 99m Tc(CO)3 labeling: synthesis and biological evaluation as potential tumor-imaging agents.

    PubMed

    Liu, Teli; Gan, Qianqian; Zhang, Junbo

    2017-02-01

    [ 99m Tc(CO) 3 (H 2 O) 3 ] + has attracted great attention among 99m Tc-labeling techniques, due to its ease of preparation, readily substituted water molecules of the precursor fac-[ 99m Tc(CO) 3 (H 2 O) 3 ] + by a variety of functional groups, small size and inertness. Bifunctional chelator based on a macrocyclic polyamine framework shows easy complexation with [ 99m Tc(CO) 3 (H 2 O) 3 ] + to produce stable complex. In this study, two novel 1, 5, 9-triazacyclododecane derivatives containing a glucose group (6 and 7) were successfully synthesized by reacting different glucose-azides with alkyne-[12]aneN 3 via the so-called click chemistry and radiolabeled with [ 99m Tc(CO) 3 (H 2 O) 3 ] + to form 99m Tc(CO) 3 -6 (C-1-substituted complex) and 99m Tc(CO) 3 -7 (C-2-substituted complex) in high yields. The complexes were stable in vitro over 6 h when incubated in saline at room temperature and in mouse serum at 37 °C. The partition coefficient results showed that they were hydrophilic. The biodistribution studies in Kunming mice bearing S 180 tumor showed both complexes showed accumulation in the tumor. Between them, 99m Tc(CO) 3 -7 had the advantages of much higher tumor uptake and tumor/muscle ratio. Compared with other reported 99m Tc-radiolabeled glucose derivatives, 99m Tc(CO) 3 -7 also showed a higher tumor uptake and tumor/muscle ratio, suggesting it would be a potential candidate for further development as a tumor-imaging agent. © 2017 John Wiley & Sons A/S.

  13. Effective visualization of suppressed thyroid tissue by means of baseline 99mTc-methoxy isobutyl isonitrile in comparison with 99mTc-pertechnetate scintigraphy after TSH stimulation.

    PubMed

    Vattimo, A; Bertelli, P; Burroni, L

    1992-01-01

    Baseline 99mTc-MIBI thyroid scintigraphy was compared with 99mTc-pertechnetate scintigraphy after TSH stimulation in seven patients with suppressed thyroid tissue due to an autonomously functioning thyroid nodule (AFTN). In all patients the suppressed thyroid tissue was visualized by means of both baseline 99mTc-MIBI and post-TSH 99mTc-pertechnetate scintigraphy, and in some cases the former technique provided better visualization. In one patient presenting a "warm" nodule T3-suppression did not affect the nodular/extranodular uptake ratio of 99mTc-MIBI, whereas the 99mTc-pertechnetate uptake ratio increased significantly. This leads us to hypothesize that the thyroid uptake of 99mTc-MIBI is not related to TSH control, but rather to other mechanisms such as the blood flow. Since exogenous TSH is no longer available, 99mTc-MIBI scintigraphy can be successfully used in the place of repeated 99mTc-pertechnetate scintigraphy after TSH stimulation in the assessment of AFTN.

  14. Minimally invasive radioguided parathyroid surgery using low-dose Tc-99m-MIBI - comparison with standard high dose.

    PubMed

    Jangjoo, Ali; Sadeghi, Ramin; Mousavi, Zohreh; Mohebbi, Masoud; Khaje, Mahtab; Asadi, Mehdi

    2017-01-01

    Surgery remains the most effective treatment for primary hyperparathyroidism (PHPT). Minimally invasive radioguided parathyroidectomy (MIRP) is a common technique for detecting and excising abnormal parathyroid glands. The aim of this study was to compare injections of low-dose and high-dose (99m) Tc methoxy isobutyl isonitrile (MIBI) for intraoperative localisation of parathyroid adenomas by means of a gamma probe in patients with primary hyperparathyroidism (PHPT). Thirty patients with PHPT and a preoperative diagnosis of parathyroid adenoma were enrolled between 2010 and 2012. They were considered as Group B and underwent MIRP using 5 mCi Tc-99m MIBI, and their perioperative data were compared with twenty patients treated with conventional 20 mCi Tc-99m MIBI previously (Group A). Group A was made up of 20 patients (mean age, 41.55 years; 14 women and 6 men), and group B included 30 patients (mean age, 40.43 years; 19 women and 11 men). The mean serum parathyroid hormone (PTH) and calcium values were recorded pre- and postoperatively. The mean follow-up period for the patients in the two groups was 18.4 and 16.5 months, respectively. Pre-operative evaluation demonstrated that the groups were statistically similar. Intraoperative data and success rate of surgery showed no difference between the two groups. No significant complication was detected after surgeries and no recurrence happened in either of the two groups during the follow-up period. A new protocol of MIRP using low doses of Tc-99m-MIBI resulted in an excellent success rate. Comparing results of the study, we conclude that low-dose Tc-99m-MIBI may be preferred for identification of parathyroid adenomas intraoperatively by means of a gamma probe in PHPT patients because it appears to be as effective as high-dose Tc-99m-MIBI.

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lieske, T.R.; Sunderrajan, E.V.; Passamonte, P.M.

    A patient with chronic eosinophilic pneumonia was evaluated using bronchoalveolar lavage, technetium-99m glucoheptonate, and transbronchial lung biopsy. Bronchoalveolar lavage revealed 43 percent eosinophils and correlated well with results of transbronchial lung biopsy. Technetium-99m glucoheptonate lung imaging demonstrated intense parenchymal uptake. After eight weeks of corticosteroid therapy, the bronchoalveolar lavage eosinophil population and the technetium-99m glucoheptonate uptake had returned to normal. We suggest that bronchoalveolar lavage, with transbronchial lung biopsy, is a less invasive way than open lung biopsy to diagnose chronic eosinophilic pneumonia. The mechanism of uptake of technetium-99m glucoheptonate in this disorder remains to be defined.

  16. A 3D Computational fluid dynamics model validation for candidate molybdenum-99 target geometry

    NASA Astrophysics Data System (ADS)

    Zheng, Lin; Dale, Greg; Vorobieff, Peter

    2014-11-01

    Molybdenum-99 (99Mo) is the parent product of technetium-99m (99mTc), a radioisotope used in approximately 50,000 medical diagnostic tests per day in the U.S. The primary uses of this product include detection of heart disease, cancer, study of organ structure and function, and other applications. The US Department of Energy seeks new methods for generating 99Mo without the use of highly enriched uranium, to eliminate proliferation issues and provide a domestic supply of 99mTc for medical imaging. For this project, electron accelerating technology is used by sending an electron beam through a series of 100Mo targets. During this process a large amount of heat is created, which directly affects the operating temperature dictated by the tensile stress limit of the wall material. To maintain the required temperature range, helium gas is used as a cooling agent that flows through narrow channels between the target disks. In our numerical study, we investigate the cooling performance on a series of new geometry designs of the cooling channel. This research is supported by Los Alamos National Laboratory.

  17. Real-time gamma imaging of technetium transport through natural and engineered porous materials for radioactive waste disposal.

    PubMed

    Corkhill, Claire L; Bridge, Jonathan W; Chen, Xiaohui C; Hillel, Phil; Thornton, Steve F; Romero-Gonzalez, Maria E; Banwart, Steven A; Hyatt, Neil C

    2013-12-03

    We present a novel methodology for determining the transport of technetium-99m, a γ-emitting metastable isomer of (99)Tc, through quartz sand and porous media relevant to the disposal of nuclear waste in a geological disposal facility (GDF). Quartz sand is utilized as a model medium, and the applicability of the methodology to determine radionuclide transport in engineered backfill cement is explored using the UK GDF candidate backfill cement, Nirex Reference Vault Backfill (NRVB), in a model system. Two-dimensional distributions in (99m)Tc activity were collected at millimeter-resolution using decay-corrected gamma camera images. Pulse-inputs of ~20 MBq (99m)Tc were introduced into short (<10 cm) water-saturated columns at a constant flow of 0.33 mL min(-1). Changes in calibrated mass distribution of (99m)Tc at 30 s intervals, over a period of several hours, were quantified by spatial moments analysis. Transport parameters were fitted to the experimental data using a one-dimensional convection-dispersion equation, yielding transport properties for this radionuclide in a model GDF environment. These data demonstrate that (99)Tc in the pertechnetate form (Tc(VII)O4(-)) does not sorb to cement backfill during transport under model conditions, resulting in closely conservative transport behavior. This methodology represents a quantitative development of radiotracer imaging and offers the opportunity to conveniently and rapidly characterize transport of gamma-emitting isotopes in opaque media, relevant to the geological disposal of nuclear waste and potentially to a wide variety of other subsurface environments.

  18. Real-Time Gamma Imaging of Technetium Transport through Natural and Engineered Porous Materials for Radioactive Waste Disposal

    PubMed Central

    2013-01-01

    We present a novel methodology for determining the transport of technetium-99m, a γ-emitting metastable isomer of 99Tc, through quartz sand and porous media relevant to the disposal of nuclear waste in a geological disposal facility (GDF). Quartz sand is utilized as a model medium, and the applicability of the methodology to determine radionuclide transport in engineered backfill cement is explored using the UK GDF candidate backfill cement, Nirex Reference Vault Backfill (NRVB), in a model system. Two-dimensional distributions in 99mTc activity were collected at millimeter-resolution using decay-corrected gamma camera images. Pulse-inputs of ∼20 MBq 99mTc were introduced into short (<10 cm) water-saturated columns at a constant flow of 0.33 mL min–1. Changes in calibrated mass distribution of 99mTc at 30 s intervals, over a period of several hours, were quantified by spatial moments analysis. Transport parameters were fitted to the experimental data using a one-dimensional convection–dispersion equation, yielding transport properties for this radionuclide in a model GDF environment. These data demonstrate that 99Tc in the pertechnetate form (Tc(VII)O4–) does not sorb to cement backfill during transport under model conditions, resulting in closely conservative transport behavior. This methodology represents a quantitative development of radiotracer imaging and offers the opportunity to conveniently and rapidly characterize transport of gamma-emitting isotopes in opaque media, relevant to the geological disposal of nuclear waste and potentially to a wide variety of other subsurface environments. PMID:24147650

  19. Radiolabeling of rituximab with (188)Re and (99m)Tc using the tricarbonyl technology.

    PubMed

    Dias, Carla Roberta; Jeger, Simone; Osso, João Alberto; Müller, Cristina; De Pasquale, Christine; Hohn, Alexander; Waibel, Robert; Schibli, Roger

    2011-01-01

    The most successful clinical studies of immunotherapy in patients with non-Hodgkin's lymphoma (NHL) use the antibody rituximab (RTX) targeting CD20(+) B-cell tumors. Rituximab radiolabeled with β(-) emitters could potentiate the therapeutic efficacy of the antibody by virtue of the particle radiation. Here, we report on a direct radiolabeling approach of rituximab with the (99m)Tc- and (188)Re-tricarbonyl core (IsoLink technology). The native format of the antibody (RTX(wt)) as well as a reduced form (RTX(red)) was labeled with (99m)Tc/(188)Re(CO)(3). The partial reduction of the disulfide bonds to produce free sulfhydryl groups (-SH) was achieved with 2-mercaptoethanol. Radiolabeling efficiency, in vitro human plasma stability as well as transchelation toward cysteine and histidine was investigated. The immunoreactivity and binding affinity were determined on Ramos and/or Raji cells expressing CD20. Biodistribution was performed in mice bearing subcutaneous Ramos lymphoma xenografts. The radiolabeling efficiency and kinetics of RTX(red) were superior to that of RTX(wt) ((99m)Tc: 98% after 3 h for RTX(red) vs. 70% after 24 h for RTX(wt)). (99m)Tc(CO)(3)-RTX(red) was used without purification for in vitro and in vivo studies whereas (188)Re(CO)(3)-RTX(red) was purified to eliminate free (188)Re-precursor. Both radioimmunoconjugates were stable in human plasma for 24 h at 37 °C. In contrast, displacement experiments with excess cysteine/histidine showed significant transchelation in the case of (99m)Tc(CO)(3)-RTX(red) but not with pre-purified (188)Re(CO)(3)-RTX(red). Both conjugates revealed high binding affinity to the CD20 antigen (K(d) = 5-6 nM). Tumor uptake of (188)Re(CO)(3)-RTX(red) was 2.5 %ID/g and 0.8 %ID/g for (99m)Tc(CO)(3)-RTX(red) 48 h after injection. The values for other organs and tissues were similar for both compounds, for example the tumor-to-blood and tumor-to-liver ratios were 0.4 and 0.3 for (99m)Tc(CO)(3)-RTX(red) and for (188)Re(CO)(3)-RTX

  20. Development of (99m)Tc-Labeled Pyridyl Benzofuran Derivatives To Detect Pancreatic Amylin in Islet Amyloid Model Mice.

    PubMed

    Yoshimura, Masashi; Ono, Masahiro; Watanabe, Hiroyuki; Kimura, Hiroyuki; Saji, Hideo

    2016-06-15

    While islet amyloid deposition comprising amylin is one of pathological hallmarks of type 2 diabetes mellitus (T2DM), no useful amylin-imaging probe has been reported. In this study, we evaluated two (99m)Tc-labeled pyridyl benzofuran derivatives as novel amylin-imaging probes using the newly established islet amyloid model mouse. Binding experiments in vitro demonstrated that [(99m)Tc]1 displayed a higher affinity for amylin aggregates than [(99m)Tc]2. Autoradiographic studies using human pancreas sections with T2DM revealed that [(99m)Tc]1 clearly labeled islet amyloid in T2DM pancreatic sections, while [(99m)Tc]2 did not. Although the initial uptake of [(99m)Tc]1 by the normal mouse pancreas was low (0.74%ID/g at 2 min post-injection), [(99m)Tc]1 showed higher retention in the model mouse pancreas than that of the normal mouse, and exhibited strong binding to amylin aggregates in the living pancreas of the model mice. These results suggest that [(99m)Tc]1 is a potential imaging probe targeting islet amyloids in the T2DM pancreas.

  1. Values of (99m)Tc-methoxyisobutylisonitrile imaging after first-time large-dose (131)I therapy in treating differentiated thyroid cancer.

    PubMed

    Pan, Xiaomei; Duan, Dong; Zhu, Yuquan; Pang, Hua; Guan, Lili; Lv, Zhixiang

    2016-01-01

    The aim of this study is to investigate the use of (99m)Tc-methoxyisobutylisonitrile (MIBI) imaging for evaluating the treatment response of differentiated thyroid cancer (DTC) after the first administration of a high dose of (131)I. Patients with DTC who received (131)I therapy underwent (99m)Tc-MIBI imaging after successive increases in the therapeutic dose of (131)I, and the serum levels of thyroglobulin (Tg) were measured. A total of 191 patients were enrolled in the final analysis, including 65 metastases and/or thyroid remnant-positive patients (22 patients with metastases and 43 patients with thyroid remnants). The sensitivity of (99m)Tc-MIBI imaging for detecting positive cases and thyroid remnants was 56.9% and 39.5%, respectively, which was significantly lower than that of (131)I imaging (92.3% and 100%, respectively, P<0.01 for both). The sensitivity of (99m)Tc-MIBI imaging for detecting metastases was 90.9%, which was slightly higher than that of (131)I imaging (77.3%, P>0.05). The Tg levels in the positive group were significantly higher than that in the negative group (P<0.01). In addition, the Tg levels in the (99m)Tc-MIBI(+)/(131)I(-) group were significantly higher than that in the (131)I(+)/(99m)Tc-MIBI group (P<0.05). After the first (131)I therapy, although (99m)Tc-MIBI imaging was able to detect the existence of metastatic lesions in patients with DTC better, its assessment for the removal efficiency of thyroid remnants was unsatisfactory. The results of (99m)Tc-MIBI imaging showed good correlations with the Tg level.

  2. The impact of serum incubation time on IgM/IgG binding to porcine aortic endothelial cells.

    PubMed

    Zhang, Zhongqiang; Gao, Bingsi; Zhao, Chengjiang; Long, Cassandra; Qi, Haizhi; Ezzelarab, Mohamed; Cooper, David Kc; Hara, Hidetaka

    2017-07-01

    The results of the assay for measuring anti-non-Gal antibodies (which affect pig xenograft survival) in recipients are important. Serum incubation time and concentration may be important factors in the extent of antibody binding to the graft. The aim of this in vitro study was to determine the optimal incubation time and serum concentration for measuring anti-non-Gal antibody binding to porcine aortic endothelial cells (pAECs). Pooled human, naive, and sensitized baboon sera were incubated with wild-type, α1,3-galactosyltransferase gene-knockout (GTKO), and GTKO/human CD55 pAECs. IgM/IgG binding to pAECs after varying serum incubation times (0.5, 1, 2, and 3 hour) and concentrations (5, 10, 20, and 40 μL) was determined by flow cytometry. An increase in incubation time from 30 minutes to 2 hour was associated with increases in anti-non-Gal IgM/IgG binding to GTKO and GTKO/hCD55 pAECs of pooled human, naive and sensitized baboon sera (P<.05). Pooled human serum showed a significant increase in anti-non-Gal IgM (1.5 times) and a minimal increase in anti-non-Gal IgG antibody binding. IgM/IgG binding of sensitized baboon serum to GTKO pAECs after 2-hour incubation was 1.5 times and 2 times greater than after 30-minutes incubation, respectively, whereas naïve baboon sera showed minimal (non-significant) increase in anti-non-Gal IgM/IgG antibody binding. With 2-hour incubation, increasing the serum concentration from 5 μL to 20 μL significantly increased antibody binding to non-Gal antigens in pooled human and sensitized baboon serum. With naïve baboon serum, only IgG was significantly increased. Increasing the serum incubation time contributed to improve the sensitivity of detecting anti-non-Gal antibodies, without affecting cell viability in vitro. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Clickable, hydrophilic ligand for fac-[M(I)(CO)3](+) (M = Re/(99m)Tc) applied in an S-functionalized α-MSH peptide.

    PubMed

    Kasten, Benjamin B; Ma, Xiaowei; Liu, Hongguang; Hayes, Thomas R; Barnes, Charles L; Qi, Shibo; Cheng, Kai; Bottorff, Shalina C; Slocumb, Winston S; Wang, Jing; Cheng, Zhen; Benny, Paul D

    2014-03-19

    The copper(I)-catalyzed azide-alkyne cycloaddition (CuAAC) click reaction was used to incorporate alkyne-functionalized dipicolylamine (DPA) ligands (1 and 3) for fac-[M(I)(CO)3](+) (M = Re/(99m)Tc) complexation into an α-melanocyte stimulating hormone (α-MSH) peptide analogue. A novel DPA ligand with carboxylate substitutions on the pyridyl rings (3) was designed to increase the hydrophilicity and to decrease in vivo hepatobiliary retention of fac-[(99m)Tc(I)(CO)3](+) complexes used in single photon emission computed tomography (SPECT) imaging studies with targeting biomolecules. The fac-[Re(I)(CO)3(3)] complex (4) was used for chemical characterization and X-ray crystal analysis prior to radiolabeling studies between 3 and fac-[(99m)Tc(I)(OH2)3(CO)3](+). The corresponding (99m)Tc complex (4a) was obtained in high radiochemical yields, was stable in vitro for 24 h during amino acid challenge and serum stability assays, and showed increased hydrophilicity by log P analysis compared to an analogous complex with nonfunctionalized pyridine rings (2a). An α-MSH peptide functionalized with an azide was labeled with fac-[M(I)(CO)3](+) using both click, then chelate (CuAAC reaction with 1 or 3 followed by metal complexation) and chelate, then click (metal complexation of 1 and 3 followed by CuAAC with the peptide) strategies to assess the effects of CuAAC conditions on fac-[M(I)(CO)3](+) complexation within a peptide framework. The peptides from the click, then chelate strategy had different HPLC tR's and in vitro stabilities compared to those from the chelate, then click strategy, suggesting nonspecific coordination of fac-[M(I)(CO)3](+) using this synthetic route. The fac-[M(I)(CO)3](+)-complexed peptides from the chelate, then click strategy showed >90% stability during in vitro challenge conditions for 6 h, demonstrated high affinity and specificity for the melanocortin 1 receptor (MC1R) in IC50 analyses, and led to moderately high uptake in B16F10 melanoma cells

  4. Technetium-99 conjugated with methylene diphosphonate (99Tc-MDP) inhibits experimental choroidal neovascularization in vivo and VEGF-induced cell migration and tube formation in vitro.

    PubMed

    Lai, Kunbei; Xu, Li; Jin, Chenjin; Wu, Kaili; Tian, Zhen; Huang, Chuangxin; Zhong, Xiaojing; Ye, Haiyun

    2011-07-29

    To investigate the effects of (99)Tc-MDP, a decay product of (99m)Tc-MDP, on the development of choroidal neovascularization (CNV), together with its underlying mechanisms. C57BL/6J mice were used to induce CNV by laser photocoagulation. (99)Tc-MDP at the doses of 0.5 × 10(-1), 1 × 10(-1), and 2 × 10(-1) μg/kg or the same volume of PBS was intraperitoneally injected daily after photocoagulation until the end of the experiment. Seven days after laser injury, mice were perfused with fluorescein-labeled dextran, and areas of CNV were measured. Numbers of infiltrating macrophages, protein levels of VEGF, and inflammation-related molecules including intercellular adhesion molecule (ICAM)-1, tumor necrosis factor (TNF)-α, and matrix metalloproteinases (MMPs) in the RPE-choroid complex were detected 3 days after laser photocoagulation. Effects of (99)Tc-MDP on VEGF-induced endothelial cell migration and tube formation were also studied. Toxicity of (99)Tc-MDP was evaluated in vivo and in vitro. Areas of CNV were significantly suppressed by (99)Tc-MDP treatment without toxicity to the retina compared with PBS treatment in a dose-dependent manner: (99)Tc-MDP treatment of 0.5 × 10(-1) μg/kg (5698.60 ± 1037.70 μm(2)), 1 × 10(-1) μg/kg (3678.34 ± 1328.18 μm(2)), and 2 × 10(-1) μg/kg (2365.78 ± 923.80 μm(2)) suppressed the development of CNV by 36.12%, 58.76%, and 73.48%, respectively, compared with that in the PBS treatment group (8920.36 ± 1097.29 μm(2); P < 0.001). (99)Tc-MDP treatment led to significant inhibition of macrophages infiltrating to CNV together with downregulated protein expressions of VEGF, ICAM-1, TNF-α, and MMP-2. (99)Tc-MDP also showed an inhibitive effect on cell proliferation and VEGF-induced migration and capillary-like tube formation of endothelial cells. Anti-inflammatory treatment with (99)Tc-MDP has therapeutic potential for CNV-related diseases.

  5. A case of recurrent cholangitis after bile duct injury during laparoscopic cholecystectomy: value of scintigraphy with Tc-99m GSA and hepatobiliary scintigraphy for indication of lobectomy.

    PubMed

    Nishiguchi, S; Shiomi, S; Sasaki, N; Iwata, Y; Tanaka, H; Kubo, S; Hirohashi, K; Ochi, H

    2000-10-01

    A 39-year-old woman with acute cholecystitis and gallstones underwent laparoscopic cholecystectomy. She suffered from recurrent episodes of cholangitis due to injury of the major bile ducts during laparoscopic cholecystectomy. Hepatobiliary scintigraphy with Tc-99m Sn-N-pyridoxyl-5-methyltryptophan was performed. Although normal bile excretion was found from the left hepatic duct to the percutaneous transhepatic biliary drainage (PTBD) tube, excretion from the right hepatic lobe was prolonged. Scintigraphy with Tc-99m diethylenetriaminepentaacetic acid-galactosyl human serum albumin demonstrated atrophy of the right hepatic lobe and enlargement of the left hepatic lobe. Cholangiography via the PTBD tube revealed complete obstruction of the left hepatico-jejunal anastomosis and could not enhance the right intrahepatic bile duct. A right hepatic lobectomy was performed because of the atrophy, glissonitis and the absence of an appropriate bile duct for reconstruction. Postoperatively she was active and exhibited no evidence of recurrent cholangitis.

  6. 99mTc-EDDA/HYNIC-TOC in the diagnosis of differentiated thyroid carcinoma refractory to radioiodine treatment.

    PubMed

    Czepczyński, Rafał; Gryczyńska, Maria; Ruchała, Marek

    2016-01-01

    In majority of cases of differentiated thyroid carcinoma (DTC), the ablative radioiodine treatment shows high efficacy. In a small number of patients, mechanism of selective iodine uptake by the DTC cells is insufficient and alternative methods of diagnosis and treatment are needed. As demonstrated in vitro, DTC cells show expression of somatostatin recep-tors. Radiolabeled somatostatin analogs are widely used in the diagnosis of neuroendocrine tumors. The aim of the study was to evaluate the utility of peptide receptor scintigraphy with the use of 99mTc-EDDA/HYNIC-TOC in the diagnosis of DTC in patients with elevated thyroglobulin concentrations (Tg), negative WBS and no effect of the consecutive radioiodine therapies. Whole body scintigraphy as well as SPECT of neck and chest were performed 3 and 24 h after i.v. administration of 740 MBq 99mTc-EDDA/HYNIC-TOC. The obtained images were compared with other radionuclide and ra-diological imaging methods. Forty-three patients with DTC after surgery and ablative radioiodine treatment with negative WBS and elevated Tg were qualified. Patients' age: 18-83 years (mean 58.0). SRS showed foci of tracer accumulation in 29 cases (67.4%). Sensitivity was 69.0% specificity 78.6%. SRS correctly identified local recurrence in 8 pts., metastatic lymph nodes in 19 pts., lung metastases in 12 pts. and bone metastases in 5 pts. SRS showed high sensitivity in the detection of metastatic lymph nodes (100%) and bone metastases (83.3%) and lung metastases (63.2%). Positive SRS was found in pts. with higher Tg concentrations (130 ± 144 vs. 30 ± 54 ng/ml). Scintigraphy with the use of the studied technetium-99m-labeled somatostatin analog is useful in the evaluation of patients with advanced DTC. It shows relatively good sensitivity and specificity but not high enough to be recommended as a routine imaging method. The role of somatostatin receptor scintigraphy in DTC is complementary to other imaging modalities.

  7. Synthesis and antimicrobial evaluation of two peptide LyeTx I derivatives modified with the chelating agent HYNIC for radiolabeling with technetium-99m.

    PubMed

    Fuscaldi, Leonardo Lima; Dos Santos, Daniel Moreira; Pinheiro, Natália Gabriela Silva; Araújo, Raquel Silva; de Barros, André Luís Branco; Resende, Jarbas Magalhães; Fernandes, Simone Odília Antunes; de Lima, Maria Elena; Cardoso, Valbert Nascimento

    2016-01-01

    Current diagnostic methods and imaging techniques are not able to differentiate septic and aseptic inflammation. Thus, reliable methods are sought to provide this distinction and scintigraphic imaging is an interesting option, since it is based on physiological changes. In this context, radiolabeled antimicrobial peptides have been investigated as they accumulate in infectious sites instead of aseptic inflammation. The peptide LyeTx I, from the venom of Lycosa erythrognatha, has potent antimicrobial activity. Therefore, this study aimed to synthesize LyeTx I derivatives with the chelating compound HYNIC, to evaluate their antimicrobial activity and to radiolabel them with (99m)Tc. Two LyeTx I derivatives, HYNIC-LyeTx I (N-terminal modification) and LyeTx I-K-HYNIC (C-terminal modification), were synthesized by Fmoc strategy and purified by RP-HPLC. The purified products were assessed by RP-HPLC and MALDI-ToF-MS analysis. Microbiological assays were performed against S. aureus (ATCC® 6538) and E. coli (ATCC® 10536) in liquid medium to calculate the MIC. The radiolabeling procedure of LyeTx I-K-HYNIC with (99m)Tc was performed in the presence of co-ligands (tricine and EDDA) and reducing agent (SnCl2 (.) 2H2O), and standardized taking into account the amount of peptide, reducing agent, pH and heating. Radiochemical purity analysis was performed by thin-layer chromatography on silica gel strips and the radiolabeled compound was assessed by RP-HPLC and radioactivity measurement of the collected fractions. Data were analyzed by ANOVA, followed by Tukey test (p-values < 0.05). Both LyeTx I derivatives were suitably synthesized and purified, as shown by RP-HPLC and MALDI-ToF-MS analysis. The microbiological test showed that HYNIC-LyeTx I (N-terminal modification) did not inhibit bacterial growth, whereas LyeTx I-K-HYNIC (C-terminal modification) showed a MIC of 5.05 μmol(.)L(-1) (S. aureus) and 10.10 μmol(.)L(-1) (E. coli). Thus, only the latter was radiolabeled

  8. Microbial methods of reducing technetium

    DOEpatents

    Wildung, Raymond E [Richland, WA; Garland, Thomas R [Greybull, WY; Gorby, Yuri A [Richland, WA; Hess, Nancy J [Benton City, WA; Li, Shu-Mei W [Richland, WA; Plymale, Andrew E [Richland, WA

    2001-01-01

    The present invention is directed toward a method for microbial reduction of a technetium compound to form other compounds of value in medical imaging. The technetium compound is combined in a mixture with non-growing microbial cells which contain a technetium-reducing enzyme system, a stabilizing agent and an electron donor in a saline solution under anaerobic conditions. The mixture is substantially free of an inorganic technetium reducing agent and its reduction products. The resulting product is Tc of lower oxidation states, the form of which can be partially controlled by the stabilizing agent. It has been discovered that the microorganisms Shewanella alga, strain Bry and Shewanelia putrifacians, strain CN-32 contain the necessary enzyme systems for technetium reduction and can form both mono nuclear and polynuclear reduced Tc species depending on the stabilizing agent.

  9. Effect of Dietary Intake of Stable Iodine on Dose-per-unit-intake Factors for 99Tc

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strom, Daniel J.

    It is well-known that the human thyroid concentrates iodine more than 100 times the concentration in plasma. Also well-known is the fact that large amounts of stable iodine in the diet can limit thyroid uptake of total iodine; this is the basis for administering potassium iodide following a release of radioiodine from a nuclear reactor accident or nuclear weapon detonation. Many researchers have shown enhanced concentrations of both organic and inorganic iodine in saliva and breast milk. Technetium-99 is a long-lived (231,000 year half-life) radionuclide of concern in the management of high-level radioactive waste. There is no doubt that 99Tc,more » if it is in groundwater, will be found in the chemical form of pertechnetate, 99TcO4?. Pertechnetate is a large anion, almost identical in size to iodide, I?. The nuclear medicine literature shows that pertechnetate concentrates in the thyroid, salivary glands, and lactating breast in addition to the stomach, liver, and alimentary tract as currently recognized by the International Commission on Radiological Protection (ICRP). The fact that large intakes of stable iodine (127I) in the diet limit uptake of iodine by the thyroid leads one to generalize that stable iodine in the diet may also limit thyroid uptake of pertechnetate. While there is at least one report that iodine in the diet blocks uptake of 99mTcO4? by the thyroid and salivary glands (which have the same Na/I symporter, the biochemical concentration mechanism), the level of protective effect seen for blocking radioactive iodine is not expected for 99TcO4? because pertechnetate does not become organically bound in the thyroid and thus is not retained for months the way iodide is. While it does account for Tc concentration in the thyroid, the existing ICRP biokinetic model for technetium does not take enhanced concentrations in salivary gland and breast tissue into account. From the survey of the nuclear medicine literature, it is not possible to compute the

  10. An Experimental Comparison of Two Different Technetium Source Activities Which Can Imitate Thyroid Scintigraphy in Case of Thyroid Toxic Nodule

    PubMed Central

    Miftari, Ramë; Fejza, Ferki; Bicaj, Xhavit; Nura, Adem; Topciu, Valdete; Bajrami, Ismet

    2014-01-01

    Purpose: In cases of thyroid toxic autonomous nodule, anterior projection of Tc-99m pertechnetate image shows a hot nodule that occupies most, or the entire thyroid lobe with near-total or total suppression of the contra lateral lobe. In this case is very difficult to distinguish toxic nodule from lobe agenesis. Our interest was to estimate and determinate the rate of radioactivity when the source with high activity can make total suppression of the second source with low activity in same conditions with thyroid scintigraphy procedures. Material and methodology: Thyroid scintigraphy was performed with Technetium 99 meta stable pertechnetate. A parallel high resolution low energy collimator was used as an energy setting of 140 KeV photo peak for T-99m. Images are acquired at 200 Kilo Counts in the anterior projection with the collimator positioned as close as the patient’s extended neck (approximately in distance of 18 cm). The scintigraphy of thyroid gland was performed 15 minutes after intravenous administration of 1.5 mCi Tc-99m pertechnetate. Technetium 99 meta stable radioactive sources with different activity were used for two scintigraphies studies, performed in same thyroid scintigraphy acquisition procedures. In the first study, were compared the standard source with high activity A=11.2 mCi with sources with variable activities B=1.33 mCi; 1.03 mCi; 0.7 mCi; 0.36 mCi; and 0.16mCi) in distance of 1.5cm from each other sources, which is approximately same with distance between two thyroid lobes. In the second study were compared the sources with low activity in proportion 70:1(source A = 1.5 mCi and source B=0.021mCi). As clinical studies we preferred two different patents with different thyroid disorders. There were one patient with thyroid toxic nodule in the right lobe, therefore the second patient was with left thyroid nodule agenesis. Results: During our examination, we accurately determined that two radioactive sources in proportion 70:1 will be

  11. A Study of Tungsten-Technetium Alloys

    NASA Technical Reports Server (NTRS)

    Maltz, J. W.

    1965-01-01

    Technetium is a sister element to rhenium and has many properties that are similar to rhenium. It is predicted that technetium will have about the same effects on tungsten as rhenium in regard to increase in workability, lowered ductile to brittle transition temperature, and improved ductility. The objectives of the current work are to recover technetium from fission product wastes at Hanford Atomic Products Operation and reduce to purified metal; prepare W-Tc alloys containing up to 50 atomic% Tc; fabricate the alloy ingots to sheet stock, assessing the effect of technetium on workability; and perform metallurgical and mechanical properties evaluation of the fabricated alloys. Previous reports have described the separation and purification of 800 g of technetium metal powder, melting of technetium and W-Tc alloys, and some initial observation of the alloy material.

  12. STUDY OF THE ADSORPTION ON AND DESORPTION FROM POLYSTYRENE-HUMAN SERUM ALBUMIN CONJUGATES OF RABBIT ANTI-HUMAN SERUM ALBUMIN ANTIBODIES HAVING DIFFERENT SPECIFICITIES

    PubMed Central

    Webb, Tom; Lapresle, Claude

    1961-01-01

    An insoluble specific adsorbent for anti-human serum albumin antibodies was prepared by coupling human serum albumin (H.S.A.) to polystyrene by azo bonds. Rabbit anti-H.S.A. immune serum was passed through a column of the adsorbent. It was shown that different volumes of the immune serum were required for the saturation of the different determinant groups of H.S.A. by their corresponding antibodies. The elution of the anti-H.S.A. antibodies adsorbed on the column was achieved by passing successively through the column an acetate buffer pH 3.0 and a solution of 0.1 N HCl in 0.15 M NaCl. The antibodies were eluted in three different fractions, each of which was composed of γ-globulins only. These three fractions contained different proportions of antibodies of different specificities. PMID:13783579

  13. Phenolic aminocarboxylate chelates of 99mTc as hepatobiliary agents.

    PubMed

    Hunt, F C; Maddalena, D J; Wilson, J G; Bautovich, G J

    1986-01-01

    A series of alkyl- and halogen-substituted derivatives of ethylenediamine di[o-hydroxyphenylacetic acid] (EDDHA) and N,N'-bis[2-hydroxybenzyl] ethylenediamine N,N'-diacetic acid (HBED) were complexed with 99mTc and their biodistribution was determined in rats. All complexes displayed substantial hepatobiliary excretion; of each series, 99mTc-Br-EDDHA and 99mTc-di-Cl-HBED had the maximum amount in the gastrointestinal tract. Scintigraphic studies of 99mTc-Cl-EDDHA in dogs revealed prompt imaging of the liver followed by imaging of the gall bladder as the complex was excreted into the bile.

  14. Correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography and clinical presentations in patients with low cobalamin status.

    PubMed

    Tu, Min-Chien; Lo, Chung-Ping; Chen, Ching-Yuan; Huang, Ching-Feng

    2015-12-03

    Cobalamin (Cbl) deficiency has been associated with various neuropsychiatric symptoms of different severities. While some studies dedicated in structural neuroimaging credibly address negative impact of low Cbl status, functional imaging reports are limited. We herein retrospectively review the correlation of Tc-99 m ethyl cysteinate dimer single-photon emission computed tomography (Tc-99 m-ECD SPECT) and clinical presentations among patients with low serum cobalamin (Cbl) status (<250 pg/ml). Twelve symptomatic patients with low serum Cbl status were enrolled. Clinical presentations, Tc-99 m-ECD SPECT, and neuropsychological tests were reviewed. Dysexecutive syndrome (67 %), forgetfulness (50 %), attention deficits (42 %), and sleep disorders (33 %) constituted the major clinical presentations. All patients (100 %) had temporal hypoperfusion on the Tc-99 m-ECD SPECT. Five patients (42 %) had hypoperfusion restricted within temporal regions and deep nuclei; seven patients (58 %) had additional frontal hypoperfusion. In patients with hypoperfusion restricted within temporal regions and deep nuclei, psychiatric symptoms with spared cognition were their main presentations. Among patients with additional frontal hypoperfusion, six of seven patients (86 %) showed impaired cognitive performances (two of them were diagnosed as having dementia). Among ten patients who finished neuropsychological tests, abstract thinking (70 %) was the most commonly affected, followed by verbal fluency (60 %), short-term memory (50 %), and attention (50 %). Anxiety and sleep problems were the major clinically remarkable psychiatric features (33 % both). Four Tc-99 m-ECD SPECT follow-up studies were available; the degree and extent of signal reversal correlated with cognitive changes after Cbl replacement therapy. Our TC-99 m-ECD SPECT observations provide pivotal information of neurobiological changes within basal ganglia and fronto-temporal regions in conjunction with disease severity

  15. Evaluation of left ventricular wall motion and function in patients with previous myocardial infarction by three-dimensional 99mTc-HSAD multigated cardiac pool imaging.

    PubMed

    Yamazaki, J; Naitou, K; Ishida, S; Uno, N; Saisho, K; Munakata, T; Morishita, T; Takano, M; Yabe, Y

    1997-05-01

    To evaluate left ventricular (LV) wall motion stereoscopically from all directions and to calculate the LV volume by three-dimensional (3D) imaging. 99mTc-DTPA human serum albumin-multigated cardiac pool-single photon emission computed tomography (99mTc-MUGA-SPECT) was performed. A new data processing program was developed with the Application Visualization System-Medical Viewer (AVS-MV) based on images obtained from 99mTc-MUGA-SPECT. In patients with previous myocardial infarction, LV function and LV wall motion were evaluated by 3D-99mTc-MUGA imaging. The LV end-diastolic volume (LVEDV) and end-systolic volume (LVESV) were obtained from 3D-99mTc-MUGA images by the surface rendering method, and the left ventricular ejection fraction (LVEF) was calculated at thresholds of 35% (T1), 40% (T2), 45% (T3), and 50% (T4). There was a strong correlation between the LV volume calculated by 3D-99mTc-MUGA imaging at a threshold of 40% and that determined by contrast left ventriculography (LVEDV: 194.7 +/- 36.0 ml vs. 198.7 +/- 39.1 ml, r = 0.791, p < 0.001; LVESV: 91.6 +/- 44.5 ml vs. 93.3 +/- 41.3 ml, r = 0.953, p < 0.001), respectively. When compared with the LVEF data obtained by left ventriculography, significant correlations were found for 3D images reconstructed at each threshold (T1: r = 0.966; T2: r = 0.962; T3: r = 0.958; and T4: r = 0.955). In addition, when LV wall motion obtained by 3D-99mTc-MUGA imaging (LAT and LAO views) was compared with the results obtained by left ventriculography (RAO and LAO views), there was good agreement. 3D-99mTc-MUGA imaging was superior in allowing evaluation of LV wall motion in all directions and in assessment of LV function, since data acquisition and image reconstruction could be done within a short time with the three-detector imaging system and AVS-MV. This method appears to be very useful for the observation of both LV wall motion and LV function in patients with ischemic heart disease, because it is a noninvasive examination.

  16. SPECT Imaging of Mice with 99mTc-Radiopharmaceuticals Obtained from 99Mo Produced by 100Mo(n,2n)99Mo and Fission of 235U

    NASA Astrophysics Data System (ADS)

    Hashimoto, Kazuyuki; Nagai, Yasuki; Kawabata, Masako; Sato, Nozomi; Hatsukawa, Yuichi; Saeki, Hideya; Motoishi, Shoji; Ohta, Masayuki; Konno, Chikara; Ochiai, Kentaro; Kawauchi, Yukimasa; Ohta, Akio; Shiina, Takayuki; Takeuchi, Nobuhiro; Ashino, Hiroki; Nakahara, Yuto

    2015-04-01

    The distribution of 99mTc-radiopharmaceutical in mouse was determined by single photon emission computed tomography (SPECT) for the first time using 99mTc, which was separated by thermochromatography from 99Mo produced via the 100Mo(n,2n)99Mo reaction with accelerator neutrons. The SPECT image was comparable to that obtained using the fission product 99Mo. Radionuclidic and radiochemical purities of the separated 99mTc and its aluminum concentration met the United States Pharmacopeia regulatory requirements for 99mTc from the fission product 99Mo. These results provide important evidence that the 99mTc-radiopharmaceutical formulated using the (n,2n) 99Mo can be a promising substitute for the fission product 99Mo. The current and forthcoming problem of ensuring a reliable and constant supply of 99Mo in Japan can be partially mitigated.

  17. Quantification of human and rodent brown adipose tissue function using 99mTc-methoxyisobutylisonitrile SPECT/CT and 18F-FDG PET/CT.

    PubMed

    Cypess, Aaron M; Doyle, Ashley N; Sass, Christina A; Huang, Tian Lian; Mowschenson, Peter M; Rosen, Harold N; Tseng, Yu-Hua; Palmer, Edwin L; Kolodny, Gerald M

    2013-11-01

    For brown adipose tissue (BAT) to be effective at consuming calories, its blood flow must increase enough to provide sufficient fuel to sustain energy expenditure and also transfer the heat created to avoid thermal injury. Here we used a combination of human and rodent models to assess changes in BAT blood flow and glucose utilization. (99m)Tc-methoxyisobutylisonitrile (MIBI) SPECT (n = 7) and SPECT/CT (n = 74) scans done in adult humans for parathyroid imaging were reviewed for uptake in regions consistent with human BAT. Site-directed biopsies of subcutaneous and deep neck fat were obtained for electron microscopy and gene expression profiling. In mice, tissue perfusion was measured with (99m)Tc-MIBI (n = 16) and glucose uptake with (18)F-FDG (n = 16). Animals were kept fasting overnight, anesthetized with pentobarbital, and given intraperitoneally either the β3-adrenergic receptor agonist CL-316,243, 1 mg/kg (n = 8), or saline (n = 8) followed by radiotracer injection 5 min later. After 120 min, the mice were imaged using SPECT/CT or PET/CT. Vital signs were recorded over 30 min during the imaging. BAT, white adipose tissue (WAT), muscle, liver, and heart were resected, and tissue uptake of both (99m)Tc-MIBI and (18)F-FDG was quantified by percentage injected dose per gram of tissue and normalized to total body weight. In 5.4% of patients (4/74), (99m)Tc-MIBI SPECT/CT showed increased retention in cervical and supraclavicular fat that displayed multilocular lipid droplets, dense capillary investment, and a high concentration of ovoid mitochondria. Expression levels of the tissue-specific uncoupling protein-1 were 180 times higher in BAT than in subcutaneous WAT (P < 0.001). In mice, BAT tissue perfusion increased by 61% (P < 0.01), with no significant changes in blood flow to WAT, muscle, heart, or liver. CL-316,243 increased glucose uptake in BAT even more, by 440% (P < 0.01). Pharmacologic activation of BAT requires increased blood flow to deliver glucose and

  18. Examination of Technetium Transport Through Soils Under Contrasting Redox Conditions: Batch and Column Work

    NASA Astrophysics Data System (ADS)

    Dozier, R.; Montgomery, D.; Wylie, E. M.; Dogan, M.; Moysey, S. M.; Powell, B. A.; Martinez, N. E.

    2015-12-01

    Experiments were performed under various reducing conditions to evaluate the transport behavior of technetium-99 (99Tc) in the presence of sandy clay loam soil from the Savannah River Site (SRS) and goethite, magnetite, and iron sulfide, which were selected for their increasing reducing potential. The experiments were conducted to investigate how redox reaction equilibria and rates affect the overall mobility of 99Tc as it transitions between the mobile Tc(VII) and immobile Tc(IV). Under oxygen-rich conditions, batch sorption isotherms measured for TcO4- across the concentration range 0.5 to 50 μg/L were linear with distribution coefficients (Kd) of 0.78 mL/g or lower, with decreasing sorption for goethite, magnetite, and iron sulfide, respectively. Addition of Na2S resulted in a marked increase in apparent 99Tc sorption to the solid phase, with Kd of 43 mL/g, 35 mL/g, and 29 mL/g, following the same mineral trend as previously. The increased Kd values are possibly due to reduction of Tc(VII) to Tc(IV), resulting in the formation of TcO2(s). SRS soil batch sorption isotherms measured for TcO4- across the same concentration range were also linear, with Kd of 0.7 mL/g for unadjusted pH, 5.1 mL/g for pH of around 6, and 6.7 mL/g for pH of around 4. Kinetic batch sorption tests showed less than 10% 99Tc sorption in an oxidizing environment and greater than 95% sorption in a reducing environment, with both reactions occurring on the order of minutes. In contrast, desorption experiments initiated by transferring the samples from a reducing environment (0.1% H2(g)/99.9% N2(g)) to atmospheric conditions resulted in a slow desorption step on the order of days. Column experiments conducted with the SRS sands indicate a retardation factor of 1.17 for 99Tc under oxygen rich conditions. Additional column experiments are being conducted to evaluate 99Tc transport dependencies on transitions between oxygen rich and poor conditions.

  19. Blood-brain barrier dysfunction following traumatic brain injury: correlation of K(trans) (DCE-MRI) and SUVR (99mTc-DTPA SPECT) but not serum S100B.

    PubMed

    Winter, Craig; Bell, Christopher; Whyte, Timothy; Cardinal, John; Macfarlane, David; Rose, Stephen

    2015-07-01

    Damage to the blood-brain barrier (BBB) is an important secondary mechanism that occurs following traumatic brain injury (TBI) and may provide a potential therapeutic target to improve patient outcome. For such a progress to be realised, an accurate assessment of BBB compromise needs to be established. Fourteen patients with TBI were prospectively recruited. Post-traumatic BBB dysfunction was assessed using dynamic contrast-enhanced MRI (DCE-MRI), single-photon emission computerised tomography (SPECT) and serum S100B levels. A statistically significant correlation between standardised uptake value ratio (SUVR) calculated from 99mTc-DTPA SPECT and K(trans) (a volume transfer constant) from DCE-MRI was found for those eight patients who had concurrent scans. The positive correlation persisted when the data were corrected for patient age, number of days following trauma and both parameters combined. We found no statistically significant correlation between either of the imaging modalities and concurrent serum S100B levels. The correlation of SPECT with DCE-MRI suggests that either scan may be used to assess post-traumatic BBB damage. We could not support serum S100B to be an accurate measure of BBB damage when sampled a number of days following injury but the small number of patients, the heterogeneity in TBI patients and the delay following injury makes any firm conclusions regarding S100B and BBB difficult.

  20. Fractal Dimension of Tc-99m DTPA GSA Estimates Pathologic Liver Injury due to Chemotherapy in Liver Cancer Patients.

    PubMed

    Hiroshima, Yukihiko; Shuto, Kiyohiko; Yamazaki, Kazuto; Kawaguchi, Daisuke; Yamada, Masatoshi; Kikuchi, Yutaro; Kasahara, Kohei; Murakami, Takashi; Hirano, Atsushi; Mori, Mikito; Kosugi, Chihiro; Matsuo, Kenichi; Ishida, Yasuo; Koda, Keiji; Tanaka, Kuniya

    2016-12-01

    Chemotherapy-induced liver injury after potent chemotherapy is a considerable problem in patients undergoing liver resection. The aim of this study was to assess the relationship between the fractal dimension (FD) of Tc-99m diethylenetriaminepentaacetic acid (DTPA) galactosyl human serum albumin (GSA) and pathologic change of liver parenchyma in liver cancer patients who have undergone chemotherapy. We examined 34 patients (10 female and 24 male; mean age, 68.5 years) who underwent hepatectomy. Hepatic injury was defined as steatosis more than 30 %, grade 2-3 sinusoidal dilation, and/or steatohepatitis Kleiner score ≥4. Fractal analysis was applied to all images of Tc-99m DTPA GSA using a plug-in tool on ImageJ software (NIH, Bethesda, MD). A differential box-counting method was applied, and FD was calculated as a heterogeneity parameter. Correlations between FD and clinicopathological variables were examined. FD values of patients with steatosis and steatohepatitis were significantly higher than those without (P > .001 and P > .001, respectively). There was no difference between the FD values of patients with and without sinusoidal dilatation (P = .357). Multivariate logistic regression showed FD as the only significant predictor for steatosis (P = .005; OR 36.5; 95 % CI 3.0-446.3) and steatohepatitis (P = .012; OR, 29.1; 95 % CI 2.1-400.1). FD of Tc-99m DTPA GSA was the significant predictor for fatty liver disease in patients who underwent chemotherapy. This new modality is able to differentiate steatohepatitis from steatosis; therefore, it may be useful for predicting chemotherapy-induced pathologic liver injury.

  1. Imaging Thromboembolism with Fibrin-Avid 99mTc-Peptide: Evaluation in Swine

    PubMed Central

    Aruva, Mohan R.; Daviau, Judy; Sharma, Shubh S.; Thakur, Mathew L.

    2006-01-01

    A pentapeptide, Gly-Pro-Arg-Pro-Pro, with high affinity for α-chain-fibrin was labeled with 99mTc (99mTc-TP850) and evaluated in swine to image experimental venous thromboembolism (deep vein thrombosis [DVT]) and pulmonary embolism (PE). Methods Scatchard analysis was performed to determine fibrin affinity for TP850 and the number of binding sites (receptors) per milligram of fibrin. DVT was induced in the left jugular vein and PE was induced by introducing a preformed autologous blood clot into the right atrium using a 7-French introducer sheath inserted into the right jugular vein. 99mTc-TP850 was injected at 4, 24, 48, 72, 96, or 120 h later. Animals were imaged for up to 4 h after injection, heparinized, and sacrificed. Lungs were extirpated, radiographed, and imaged, and the PE was removed. Other tissues, including blood and normal lungs, were harvested and, concomitantly, 99mTc was counted for determination of target-to-tissue ratios and the percentage injected dose per gram of tissue. Results The affinity for human fibrin was 10−9 mol/L and there were >1015 receptors per milligram of fibrin. DVT and PE were visualized for up to 4 h after injection with high DVT/blood (7.9–22.6), DVT/muscle (31.1–89.4), PE/blood (1–155), and PE/lung (0.8–245) ratios. Thereafter, the PEs fragmented spontaneously below the spatial resolution of the γ-camera and, despite the high associated radioactivity, could not be localized in vivo. The fragmented clots were detectable by scintigraphy on excised lungs and provided excellent concordance with radiograms. Conclusion 99mTc-TP850 with its modest affinity (10−9 mol/L), rapid blood clearance, and high DVT and PE uptake is a promising agent for imaging vascular thrombosis. PMID:16391200

  2. Extending the half-life of a fab fragment through generation of a humanized anti-human serum albumin Fv domain: An investigation into the correlation between affinity and serum half-life.

    PubMed

    Adams, Ralph; Griffin, Laura; Compson, Joanne E; Jairaj, Mark; Baker, Terry; Ceska, Tom; West, Shauna; Zaccheo, Oliver; Davé, Emma; Lawson, Alastair Dg; Humphreys, David P; Heywood, Sam

    2016-10-01

    We generated an anti-albumin antibody, CA645, to link its Fv domain to an antigen-binding fragment (Fab), thereby extending the serum half-life of the Fab. CA645 was demonstrated to bind human, cynomolgus, and mouse serum albumin with similar affinity (1-7 nM), and to bind human serum albumin (HSA) when it is in complex with common known ligands. Importantly for half-life extension, CA645 binds HSA with similar affinity within the physiologically relevant range of pH 5.0 - pH 7.4, and does not have a deleterious effect on the binding of HSA to neonatal Fc receptor (FcRn). A crystal structure of humanized CA645 Fab in complex with HSA was solved and showed that CA645 Fab binds to domain II of HSA. Superimposition with the crystal structure of FcRn bound to HSA confirmed that CA645 does not block HSA binding to FcRn. In mice, the serum half-life of humanized CA645 Fab is 84.2 h. This is a significant extension in comparison with < 1 h for a non-HSA binding CA645 Fab variant. The Fab-HSA structure was used to design a series of mutants with reduced affinity to investigate the correlation between the affinity for albumin and serum half-life. Reduction in the affinity for MSA by 144-fold from 2.2 nM to 316 nM had no effect on serum half-life. Strikingly, despite a reduction in affinity to 62 µM, an extension in serum half-life of 26.4 h was still obtained. CA645 Fab and the CA645 Fab-HSA complex have been deposited in the Protein Data Bank (PDB) with accession codes, 5FUZ and 5FUO, respectively.

  3. Feasibility studies towards future self-sufficient supply of the 99Mo-99mTc isotopes with Japanese accelerators

    PubMed Central

    NAKAI, Kozi; TAKAHASHI, Naruto; HATAZAWA, Jun; SHINOHARA, Atsushi; HAYASHI, Yoshihiko; IKEDA, Hayato; KANAI, Yasukazu; WATABE, Tadashi; FUKUDA, Mitsuhiro; HATANAKA, Kichiji

    2014-01-01

    In order to establish a self-sufficient supply of 99mTc, we studied feasibilities to produce its parent nucleus, 99Mo, using Japanese accelerators. The daughter nucleus, 99mTc, is indispensable for medical diagnosis. 99Mo has so far been imported from abroad, which is separated from fission products generated in nuclear reactors using enriched 235U fuel. We investigated 99mTc production possibilities based on the following three scenarios: (1) 99Mo production by the (n, 2n) reaction by spallation neutrons at the J-PARC injector, LINAC; (2) 99Mo production by the (p, pn) reaction at Ep = 50–80 MeV proton at the RCNP cyclotron; (3) 99mTc direct production with a 20 MeV proton beam from the PET cyclotron. Among these three scenarios, scenario (1) is for a scheme on a global scale, scenario (2) works in a local area, and both cases take a long time for negotiations. Scenario (3) is attractive because we can use nearly 50 PET cyclotrons in Japan for 99mTc production. We here consider both the advantages and disadvantages among the three scenarios by taking account of the Japanese accelerator situation. PMID:25504230

  4. Occult abnormal pregnancies after first post-embryo transfer serum beta-human chorionic gonadotropin levels of 1.0-5.0 mIU/mL.

    PubMed

    Maslow, Bat-Sheva L; Bartolucci, Alison; Sueldo, Carolina; Engmann, Lawrence; Benadiva, Claudio; Nulsen, John C

    2016-04-01

    To assess the occult pregnancy rate after "negative" first post-embryo transfer (ET) serum β-hCG results. Two-part retrospective cohort study and nested case series. University-based fertility center. A total of 1,571 negative first post-ET serum β-hCG results were included in the study; 1,326 results (primary cohort, June 2009-December 2013) were initially reported as <5 mIU/mL and 245 results (secondary cohort, January 2014-March 2015) were reported as discrete values from 1.0 to 5.0 mIU/mL. None. Rates of occult pregnancy, ectopic pregnancy, and complications after negative first post-ET serum β-hCG results. A total of 88.8% (1,178/1,326) of the negative first post-ET results reported as <5 were actually <1.0 mIU/mL. Occult pregnancy was incidentally identified in 1.2% (12/1,041) of subjects with follow-up. Six had ectopic pregnancies, and seven experienced serious complications; 11 (91.7%) of the 12 occult pregnancies had a first post-ET serum β-hCG level of 1.0-5.0 mIU/mL and 1 (8.3%) <1.0 mIU/mL. All pregnancies with serious complications had initial β-hCG levels of 1.0-5.0 mIU/mL. Of the 245 results reported as discreet values, occult pregnancies were diagnosed in 5.5% (9/163) of subjects with follow-up. One had an ectopic pregnancy, which was treated with methotrexate. There were no serious complications in the secondary cohort. The majority of negative first post-ET serum β-hCG levels are <1.0 mIU/mL. Results from 1.0 to 5.0 mIU/mL may fail to exclude abnormal pregnancy and are associated with poor outcomes compared with β-hCG levels <1.0 mIU/mL. Serial serum β-hCG may be warranted in this population. Copyright © 2016 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  5. 99mTc-labeling of HYNIC-conjugated cyclic RGDfK dimer and tetramer using EDDA as coligand.

    PubMed

    Wang, Jianjun; Kim, Young-Seung; Liu, Shuang

    2008-03-01

    In this study, EDDA (ethylenediamine- N, N'-diacetic acid) was used as the coligand for 99mTc-labeling of cyclic RGDfK conjugates: HYNIC-dimer (HYNIC = 6-hydrazinonicotinamide; dimer = E[c(RGDfK)]2) and HYNIC-tetramer (tetramer = E{E[c(RGDfK)]2}2). First, HYNIC-dimer was allowed to react with 99mTcO4 (-) in the presence of excess tricine and stannous chloride to form the intermediate complex [99mTc(HYNIC-dimer)(tricine)2], which was then allowed to react with EDDA to afford [99mTc(HYNIC-dimer)(EDDA)] with high yield (>90%) and high specific activity ( approximately 8.0 Ci/micromol). Under the same radiolabeling conditions, the yield for [99mTc(HYNIC-tetramer)(EDDA)] was always <65%. The results from a mixed-ligand experiment show that there is only one EDDA bonding to the 99mTc-HYNIC core in [99mTc(HYNIC-dimer)(EDDA)]. The athymic nude mice bearing subcutaneous U87MG human glioma xenografts were used to evaluate the impact of EDDA coligand on the biodistribution characteristics and excretion kinetics of the 99mTc-labeled HYNIC-dimer and HYNIC-tetramer. Surprisingly, [99mTc(HYNIC-dimer)(EDDA)] and [99mTc(HYNIC-tetramer)(EDDA)] had almost identical tumor uptake over the 2 h period. The use of EDDA as coligand to replace tricine/TPPTS (TPPTS = trisodium triphenylphosphine-3,3',3''-trisulfonate) did not significantly change the uptake of the 99mTc-labeled HYNIC-dimer in noncancerous organs, such as the liver, kidneys, and lungs; but it did result in a significantly lower kidney uptake for the 99mTc-labeled HYNIC-tetramer due to faster renal excretion. It was also found that the radiotracer tumor uptake decreases in a linear fashion as the tumor size increases. The smaller the tumors are, the higher the tumor uptake is regardless of the identity of radiotracer.

  6. Lung clearance of /sup 99m/Tc-DTPA in patients with acute lung injury and pulmonary edema

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coates, G.; O'Brodovich, H.; Dolovich, M.

    1988-07-01

    Several acute and chronic conditions that alter the integrity of the pulmonary epithelium increased the rate of absorption or clearance into the circulation of small solutes deposited in the alveoli. Technetium 99m diethylenetriamine pentaacetic acid can be deposited in the lungs as a submicronic aerosol and its rate of clearance measured with a gamma camera or simple probe. This clearance technique is currently being used to evaluate patients who have developed pulmonary edema and also to detect those patients from a high risk group who are likely to develop adult respiratory distress syndrome (ARDS). Its role in the evaluation ofmore » patients with pulmonary edema is still under active investigation. It is clear that a single measurement in patients who smoke is not useful, but repeated measurements may provide important information. The lung clearance measurement is very sensitive to changes in epithelial integrity but is not specific for ARDS. It may be most useful in combination with other predictive tests or when the clearance rate is normal. 54 references.« less

  7. Small Column Testing of Superlig 639 for Removal of 99Tc from Hanford Tank Waste Envelope C (Tank 241-AN-107)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    DL Blanchard; DE Kurath; BM Rapko

    The current BNFL Inc. flow sheet for pretreating Hanford High-Level tank wastes includes the use of Superlig(reg.sign)639 (SL-639) in a dual column system for removing technetium-99 ({sup 99}Tc) from the aqueous fraction of the waste. This sorbent material has been developed and supplied by IBC Advanced Technologies, Inc., American Fork, UT. This report documents the results of testing the SL-639 sorbent with diluted waste [Na{sup +}] {approx} 5 M from Tank 241-AN-107 (an Envelope C waste, abbreviated AN-107) at Battelle Northwest Laboratories (BNW). The equilibrium behavior was assessed with batch contacts between the sorbent and the waste. Two AN-107 samplesmore » were used: (1) an archived sample from previous testing and (2) a more recent sample collected specifically for BNFL. A portion of the archive sample and all of the BNFL sample were treated to remove Sr-90 and transuranic elements (TRU). All samples had also been Cs decontaminated by ion exchange (IX), and were spiked with a technetium-95m ({sup 95m}Tc) pertechnetate tracer, {sup 95m}TcO{sub 4}{sup -}.The TcO{sub 4}{sup -} and total Tc K{sub d} values, assumed equal to the {sup 95m}Tc and {sup 99}Tc K{sub d}'s, respectively, are shown in Table S1. Values are averages of duplicates, which showed significant scatter. The total Tc K{sub d} for the BNFL sample is much lower than the TcO{sub 4}{sup -}, indicating that a large fraction of the {sup 99}Tc is not pertechnetate.« less

  8. Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum

    PubMed Central

    Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah

    2015-01-01

    In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL-1 and 2-20 μg mL-1 in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum. PMID:26330859

  9. Square Wave Voltammetric Determination of Diclofenac in Pharmaceutical Preparations and Human Serum.

    PubMed

    Ciltas, Ulvihan; Yilmaz, Bilal; Kaban, Selcuk; Akcay, Bilge Kaan; Nazik, Gulsah

    2015-01-01

    In this study, a simple and reliable square wave voltammetric (SWV) method was developed and validated for determination of diclofenac in pharmaceutical preparations and human serum. The proposed method was based on electrooxidation of diclofenac at platinum electrode in 0.1 M TBAClO4/acetonitrile solution. The well-defined two oxidation peaks were observed at 0.87 and 1.27 V, respectively. Calibration curves that were obtained by using current values measured for second peak were linear over the concentration range of 1.5-17.5 μg mL(-1) and 2-20 μg mL(-1) in supporting electrolyte and serum, respectively. Precision and accuracy were also checked in all media. Intra- and inter-day precision values for diclofenac were less than 3.64, and accuracy (relative error) was better than 2.49%. Developed method in this study is accurate, precise and can be easily applied to Diclomec, Dicloflam and Voltaren tablets as pharmaceutical preparation. Also, the proposed technique was successfully applied to spiked human serum samples. No electroactive interferences from the endogenous substances were found in human serum.

  10. Evaluation of normality and reproducibility parameters of scintigraphy with (99m)Tc-MAA in the diagnosis of intrapulmonary vascular dilatations.

    PubMed

    de Queirós, Andréa Simone Siqueira; Brandão, Simone Cristina Soares; Macedo, Liana Gonçalves; Ourem, Maira Souto; Mota, Vitor Gomes; Leite, Luiz Arthur Calheiros; Lopes, Edmundo Pessoa Almeida; Domingues, Ana Lúcia Coutinho

    2015-01-01

    The formation of intrapulmonary vascular dilations (IPVD) is the key event for the onset of hepatopulmonary syndrome, vascular changes secondary to portal hypertension that leads to hypoxemia. The diagnosis of IPVD can be made by contrasted transthoracic echocardiography or scintigraphy with technetium-macroaggregated albumin-((99m)Tc-MAA)-that is a sensitive and specific diagnostic method and quantifies the IPVD magnitude. However, its procedure and diagnostic indices are not yet standardized and well defined in health services. The aims of this study were to define normality values and evaluate the inter- and intra-observer reproducibility degree of diagnostic indexes of IPVD through (99m)Tc-MAA scintigraphy. Cross-sectional study was conducted at the Clinical Hospital, Federal University of Pernambuco (HC-UFPE) between July and December 2012. Fifteen patients with hepatosplenic schistosomiasis and nine patients without liver or heart disease (control group) were assessed. After clinical assessment, ultrasound and echocardiography, patients underwent (99m)Tc-MAA scintigraphy, and a relative brain uptake value exceeding 6 % or systemic uptake value exceeding 11 % was considered diagnostic of IPVD. Each assessment was performed by two independent observers. To analyze the results of the normal group, the nonparametric Bootsptrap method simulation model combined with the Monte Carlo method was used and to analyze inter- and intra-observer reproducibility indexes, the kappa and intra-class correlation coefficient were used. In normal subjects, the average brain uptake of (99m)Tc-MAA was 7.9 ± 0.01 % and systemic uptake was 12.4 ± 0.03 %, with low dispersal rates for both measures. The intra-observer agreement was 100 %, with kappa index of 1.0 (p < 0.0001), suggesting a perfect agreement. The inter-observer agreement was also 100 % (kappa = 1.0, p < 0.0001) for brain uptake; however, systemic uptake showed kappa = 0.25 (p = 0.07), which features

  11. Recent achievements in Tc-99m radiopharmaceutical direct production by medical cyclotrons.

    PubMed

    Boschi, Alessandra; Martini, Petra; Pasquali, Micol; Uccelli, Licia

    2017-09-01

    99m Tc is the most commonly used radionuclide in the field of diagnostic imaging, a noninvasive method intended to diagnose a disease, assess the disease state and monitor the effects of treatments. Annually, the use of 99m Tc, covers about 85% of nuclear medicine applications. This isotope releases gamma rays at about the same wavelength as conventional X-ray diagnostic equipment, and owing to its short half-life (t ½  = 6 h) is ideal for diagnostic nuclear imaging. A patient can be injected with a small amount of 99m Tc and within 24 h almost 94% of the injected radionuclide would have decayed and left the body, limiting the patient's radiation exposure. 99m Tc is usually supplied to hospitals through a 99 Mo/ 99m Tc radionuclide generator system where it is produced from the β decay of the parent nuclide 99 Mo (t ½  = 66 h), which is produced in nuclear reactors via neutron fission. Recently, the interruption of the global supply chain of reactor-produced 99 Mo, has forced the scientific community to investigate alternative production routes for 99m Tc. One solution was to consider cyclotron-based methods as potential replacement of reactor-based technology and the nuclear reaction 100 Mo(p,2n) 99m Tc emerged as the most worthwhile approach. This review reports some achievements about 99m Tc produced by medical cyclotrons. In particular, the available technologies for target design, the most efficient extraction and separation procedure developed for the purification of 99m Tc from the irradiated targets, the preparation of high purity 99m Tc radiopharmaceuticals and the first clinical studies carried out with cyclotron produced 99m Tc are described.

  12. (99m)Tc(CO)3(NTA): a (99m)Tc renal tracer with pharmacokinetic properties comparable to those of (131)I-OIH in healthy volunteers.

    PubMed

    Taylor, Andrew T; Lipowska, Malgorzata; Marzilli, Luigi G

    2010-03-01

    Studies in rats showed that the pharmacokinetics of the tricarbonyl core radiopharmaceutical (99m)Tc(CO)(3)-nitrilotriacetic acid, (99m)Tc(CO)(3)(NTA), were essentially identical to those of (131)I ortho-iodohippuran ((131)I-OIH), the clinical gold standard for the measurement of effective renal plasma flow. Our objective was to compare the pharmacokinetics of these 2 tracers in healthy volunteers. (99m)Tc(CO)(3)(NTA) was prepared with commercially available NTA and a commercially available kit and isolated by reversed-phase high-performance liquid chromatography. Approximately 74 MBq (2 mCi) of (99m)Tc(CO)(3)(NTA) were coinjected with 9.25 MBq (250 microCi) of (131)I-OIH in 9 volunteers, and simultaneous imaging of each tracer was performed for 24 min. Plasma clearances were determined from 8 blood samples obtained 3-90 min after injection using the single-injection, 2-compartment model. Plasma protein binding, red cell uptake, and percentage injected dose in the urine at 30 and 180 min were determined. There was no difference in the plasma clearances of (99m)Tc(CO)(3)(NTA) and (131)I-OIH, 475 +/- 105 mL/min versus 472 +/- 108 mL/min, respectively. The plasma protein binding and red cell uptake of (99m)Tc(CO)(3)(NTA) were 43% +/- 5% and 9% +/- 6%, respectively; both values were significantly lower (P < 0.001) than the plasma protein binding (75% +/- 3%) and red cell uptake (17% +/- 5%) of (131)I-OIH. There was no significant difference in the percentage injected dose recovered in the urine at 30 min and at 3 h; for comparison, the percentage dose in the urine at 3 h was 91% +/- 4% for (99m)Tc(CO)(3)(NTA) and 91% +/- 6% for (131)I-OIH (P = 0.96). Image quality with (99m)Tc(CO)(3)(NTA) was excellent, and the renogram parameters were similar to those of (131)I-OIH. Preliminary results in healthy volunteers suggest that the pharmacokinetic behavior of (99m)Tc(CO)(3)(NTA) is comparable to that of (131)I-OIH.

  13. BDE-99 impairs differentiation of human and mouse NPCs into the oligodendroglial lineage by species-specific modes of action

    PubMed Central

    Dach, Katharina; Bendt, Farina; Huebenthal, Ulrike; Giersiefer, Susanne; Lein, Pamela J.; Heuer, Heike; Fritsche, Ellen

    2017-01-01

    Polybrominated diphenyl ethers (PBDEs) are bioaccumulating flame retardants causing developmental neurotoxicity (DNT) in humans and rodents. Their DNT effects are suspected to involve thyroid hormone (TH) signaling disruption. Here, we tested the hypothesis whether disturbance of neural progenitor cell (NPC) differentiation into the oligodendrocyte lineage (O4+ cells) by BDE-99 involves disruption of TH action in human and mouse (h,m)NPCs. Therefore, we quantified differentiation of NPCs into O4+ cells and measured their maturation via expression of myelin-associated genes (hMBP, mMog) in presence and absence of TH and/or BDE-99. T3 promoted O4+ cell differentiation in mouse, but not hNPCs, and induced hMBP/mMog gene expression in both species. BDE-99 reduced generation of human and mouse O4+ cells, but there is no indication for BDE-99 interfering with cellular TH signaling during O4+ cell formation. BDE-99 reduced hMBP expression due to oligodendrocyte reduction, but concentrations that did not affect the number of mouse O4+ cells inhibited TH-induced mMog transcription by a yet unknown mechanism. In addition, ascorbic acid antagonized only the BDE-99-dependent loss of human, not mouse, O4+ cells by a mechanism probably independent of reactive oxygen species. These data point to species-specific modes of action of BDE-99 on h/mNPC development into the oligodendrocyte lineage. PMID:28317842

  14. BDE-99 impairs differentiation of human and mouse NPCs into the oligodendroglial lineage by species-specific modes of action.

    PubMed

    Dach, Katharina; Bendt, Farina; Huebenthal, Ulrike; Giersiefer, Susanne; Lein, Pamela J; Heuer, Heike; Fritsche, Ellen

    2017-03-20

    Polybrominated diphenyl ethers (PBDEs) are bioaccumulating flame retardants causing developmental neurotoxicity (DNT) in humans and rodents. Their DNT effects are suspected to involve thyroid hormone (TH) signaling disruption. Here, we tested the hypothesis whether disturbance of neural progenitor cell (NPC) differentiation into the oligodendrocyte lineage (O4 + cells) by BDE-99 involves disruption of TH action in human and mouse (h,m)NPCs. Therefore, we quantified differentiation of NPCs into O4 + cells and measured their maturation via expression of myelin-associated genes (hMBP, mMog) in presence and absence of TH and/or BDE-99. T3 promoted O4 + cell differentiation in mouse, but not hNPCs, and induced hMBP/mMog gene expression in both species. BDE-99 reduced generation of human and mouse O4 + cells, but there is no indication for BDE-99 interfering with cellular TH signaling during O4 + cell formation. BDE-99 reduced hMBP expression due to oligodendrocyte reduction, but concentrations that did not affect the number of mouse O4 + cells inhibited TH-induced mMog transcription by a yet unknown mechanism. In addition, ascorbic acid antagonized only the BDE-99-dependent loss of human, not mouse, O4 + cells by a mechanism probably independent of reactive oxygen species. These data point to species-specific modes of action of BDE-99 on h/mNPC development into the oligodendrocyte lineage.

  15. Elevated serum level of human alkaline phosphatase in obesity.

    PubMed

    Khan, Abdul Rehman; Awan, Fazli Rabbi; Najam, Syeda Sadia; Islam, Mehboob; Siddique, Tehmina; Zain, Maryam

    2015-11-01

    To investigate a correlation between serum alkaline phosphatase level and body mass index in human subjects. The comparative cross-sectional study was carried out at the National Institute for Biotechnology and Genetic Engineering, Faisalabad, Pakistan, from April 2012 to June 2013. Blood serum alkaline phosphatase levels were estimated and the subjects were divided into three sub-groups on the basis of their body mass. normal weight (<25kg/m2), overweight (25-27kg/m2) and obese (>27kg/m2) subjects. The serum samples were used for the estimation of clinically important biochemical parameters, using commercial kits on clinical chemistry analyser. Of the 197 subjects, 97(49%) were obese and 100(51%) were non-obese. The serum alkaline phosphatase level increased in obese (214±6.4 IU/L) compared to the non-obese subjects (184.5±5 IU/L). Furthermore, a significant linear relationship (r=0.3;p-0.0001) was found between serum alkaline phosphatase and body mass index. Other biochemical variables were not correlated to the body mass index. Over activity and higher amounts of alkaline phosphatase were linked to the development of obesity.

  16. The Human Serum Metabolome

    PubMed Central

    Psychogios, Nikolaos; Hau, David D.; Peng, Jun; Guo, An Chi; Mandal, Rupasri; Bouatra, Souhaila; Sinelnikov, Igor; Krishnamurthy, Ramanarayan; Eisner, Roman; Gautam, Bijaya; Young, Nelson; Xia, Jianguo; Knox, Craig; Dong, Edison; Huang, Paul; Hollander, Zsuzsanna; Pedersen, Theresa L.; Smith, Steven R.; Bamforth, Fiona; Greiner, Russ; McManus, Bruce; Newman, John W.; Goodfriend, Theodore; Wishart, David S.

    2011-01-01

    Continuing improvements in analytical technology along with an increased interest in performing comprehensive, quantitative metabolic profiling, is leading to increased interest pressures within the metabolomics community to develop centralized metabolite reference resources for certain clinically important biofluids, such as cerebrospinal fluid, urine and blood. As part of an ongoing effort to systematically characterize the human metabolome through the Human Metabolome Project, we have undertaken the task of characterizing the human serum metabolome. In doing so, we have combined targeted and non-targeted NMR, GC-MS and LC-MS methods with computer-aided literature mining to identify and quantify a comprehensive, if not absolutely complete, set of metabolites commonly detected and quantified (with today's technology) in the human serum metabolome. Our use of multiple metabolomics platforms and technologies allowed us to substantially enhance the level of metabolome coverage while critically assessing the relative strengths and weaknesses of these platforms or technologies. Tables containing the complete set of 4229 confirmed and highly probable human serum compounds, their concentrations, related literature references and links to their known disease associations are freely available at http://www.serummetabolome.ca. PMID:21359215

  17. Supine lung clearance of Tc-99m DTPA and HMPAO aerosols

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chia-Hung Kao; Hui-Tzu Lin; Shu-Ling Yu

    1995-07-01

    The speed of Tc-99m DTPA/HMPAO radioaerosol clearance from the lungs that is represented as a slope from lungs to blood was measured in 23 male normal controls using commercial lung radioaerosol delivery units in the supine position in order to avoid the influences of gravity. The right lung was selected and three regions of interest were created for equal subdivisions of the upper, middle, and lower third. The results show that the clearance of Tc-99m DTPA/HMPAO aerosols in the upper lung is lowest. The difference between upper and lower lungs for Tc-99m DTPA/HMPAO aerosol clearances are significant. The clearance ofmore » Tc-99m DTPA aerosols was significantly faster than those of Tc-99m HMPAO in any region. The authors conclude that, although the effect of gravity disappears in the supine position in our study, the differences of aerosol clearance in different regions are still significant. Lipophilic Tc-99m HMPAO aerosols were slower than those of hydrophilic Tc-99m DTPA, which suggests there are at least two different mechanisms. 22 refs., 2 figs., 1 tab.« less

  18. 10 CFR 33.100 - Schedule A.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... .1 Technetium-99m 100 1. Technetium-99 1 .01 Tellurium-125m 1 .01 Tellurium-127m 1 .01 Tellurium-127 10 .1 Tellurium-129m 1 .01 Tellurium-129 100 1 Tellurium-131m 10 .1 Tellurium-132 1 .01 Terbium-160 1...

  19. 10 CFR 33.100 - Schedule A.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... .1 Technetium-99m 100 1. Technetium-99 1 .01 Tellurium-125m 1 .01 Tellurium-127m 1 .01 Tellurium-127 10 .1 Tellurium-129m 1 .01 Tellurium-129 100 1 Tellurium-131m 10 .1 Tellurium-132 1 .01 Terbium-160 1...

  20. [99mTc] HYNIC-hEGF, a potential agent for imaging of EGF receptors in vivo: preparation and pre-clinical evaluation.

    PubMed

    Babaei, Mohammad Hossein; Almqvist, Ylva; Orlova, Anna; Shafii, Mohammad; Kairemo, Kalevi; Tolmachev, Vladimir

    2005-06-01

    Expression of epidermal growth factor receptors (EGFR) has prognostic and predictive value in many kinds of tumors. Imaging of expression of EGFR in vivo may give valuable diagnostic information. The epidermal growth factor (EGF), a natural ligand, is a possible candidate for the targeting of EGFR. The present study describes a method for preparation of (99m)Tc-EGF via the hydrazinopyridine-3-carboxylic acid (HYNIC) conjugation using tricine and ethylenediamine-N,N'-diacetic acid (EDDA) as co-ligands. Both conjugates bound EGFR expressing cells with nanomolar affinity, and demonstrated good intracellular retention. The complex with EDDA demonstrated much higher stability in blood serum and during cysteine challenge. Biodistribution of (99m)Tc-EDDA-HYNIC-EGF in normal mice demonstrated fast blood clearance of conjugate, and its ability to bind EGFR in vivo. (99m)Tc-EDDA-HYNIC-EGF is a promising candidate for visualization of EGFR expression in vivo.

  1. A Nuclear Reactor and Chemical Processing Design for Production of Molybdenum-99 with Crystalline Uranyl Nitrate Hexahydrate Fuel

    NASA Astrophysics Data System (ADS)

    Stange, Gary Michael

    Medical radioisotopes are used in tens of millions of procedures every year to detect and image a wide variety of maladies and conditions in the human body. The most widely-used diagnostic radioisotope is technetium-99m, a metastable isomer of technetium-99 that is generated by the radioactive decay of molybdenum-99. For a number of reasons, the supply of molybdenum-99 has become unreliable and the techniques used to produce it have become unattractive. This has spurred the investigation of new technologies that avoid the use of highly enriched uranium to produce molybdenum-99 in the United States, where approximately half of the demand originates. The first goal of this research is to develop a critical nuclear reactor design powered by solid, discrete pins of low enriched uranium. Analyses of single-pin heat transfer and whole-core neutronics are performed to determine the required specifications. Molybdenum-99 is produced directly in the fuel of this reactor and then extracted through a series of chemical processing steps. After this extraction, the fuel is left in an aqueous state. The second goal of this research is to describe a process by which the uranium may be recovered from this spent fuel solution and reconstituted into the original fuel form. Fuel recovery is achieved through a crystallization step that generates solid uranyl nitrate hexahydrate while leaving the majority of fission products and transuranic isotopes in solution. This report provides background information on molybdenum-99 production and crystallization chemistry. The previously unknown thermal conductivity of the fuel material is measured. Following this is a description of the modeling and calculations used to develop a reactor concept. The operational characteristics of the reactor core model are analyzed and reported. Uranyl nitrate crystallization experiments have also been conducted, and the results of this work are presented here. Finally, a process flow scheme for uranium

  2. Impact of sample extraction on the accurate measurement of progesterone in human serum by liquid chromatography tandem mass spectrometry.

    PubMed

    Ke, Yuyong; Gonthier, Renaud; Labrie, Fernand

    2017-05-01

    In the present study, the impact of the extraction solvent on the accuracy of endogenous progesterone assay in human serum has been investigated using two selective reaction monitoring (SRM) transitions (315>97 & 315>109). Higher levels of noise and more interference were observed when more polar solvents were used for extraction, thus resulting in serious bias of the measured values of progesterone in serum. This is confirmed by monitoring the ion ratio of 315>97-315>109. This issue could not be easily resolved by changes in MS/MS transitions or chromatography conditions. More bias was observed with the SRM transition 315>109 for the polar solvent extraction. Hexane and 1-chlorobutane (polarity index of 0 and 1, respectively) did provide the cleanest samples with a lower noise level in the chromatograms. Moreover, the measured values of progesterone were not changed with different SRM transitions or longer retention time in search of an improved separation. Recovery tests of progesterone have been performed with 1-chlorobutane in matrices with phosphate buffered saline (PBS) 1x, PBS 1×3% bovine serum albumin (BSA), stripped serum/H 2 O (1:1) and unstripped serum. The recovery (70%∼80%) consistency is observed not only at different levels but also in different matrices. The equivalent recovery between PBS 1x, PBS 1×3% BSA and unstripped serum shows that the impact of progesterone binding to serum proteins on the measurement accuracy can be avoided with this sample preparation procedure. No significant matrix effect on the determination of progesterone was observed with 1-chlorobutane. Within the range of 12.5-2000pg/mL, a good linearity is observed with R>0.99 and weighting factor 1/X. Bias and covariance efficiency of QCs are within 10%. With 1-chlorobutane as the extraction solvent, the concentration of progesterone was measured where the range for postmenopausal serum is 5.74∼91.7pg/mL, which is well below the reported concentrations of 314 pg/mL∼942pg/m

  3. Bone accumulation of the Tc-99m complex of carbamyl phosphate and its analogs

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hosain, P.; Spencer, R.P.; Ahlquist, K.J.

    1978-05-01

    Carbamyl phosphate, an organic moecule containing a single phosphate group, has been used in the therapy of sickle-cell disease. Carbamyl phosphate bound Tc-99m and achieved bone uptake in mice, rabbits, and a human volunteer. By examination of the structural formula, a working hypothesis was developed that predicted that the Tc-99m complexes of the analogous compounds acetyl phosphate, propionyl phosphate, and butyryl phosphate, each carrying single phosphate and carbonyl groups, would also show bone specificity. This was confirmed experimentally. Phosphonoacetic acid is a structural analog of these compounds. The structural analysis also predicted that aminomethylphosphonic acid and phosphoenolpyruvate would not havemore » as avid bone affinity, and this was also confirmed. These compounds represent a new class of bone-seeking agents that have the common properties of a lone phosphate and a carbonyl function. Such agents may permit the synthesis of additional analogs in an effort to obtain optimal affinity in the Tc-99m complexes.« less

  4. Preoperative localization of parathyroid carcinoma using Tc-99m MIBI.

    PubMed

    Kitapçi, M T; Tastekin, G; Turgut, M; Caner, B; Kars, A; Barista, I; Bekdik, C

    1993-03-01

    A patient with parathyroid cancer is presented who underwent Tc-99m MIBI scintigraphy. The Tc-99m MIBI image demonstrated increased accumulation of activity at the lower pole of the left thyroid lobe which was later confirmed as a parathyroid cancer. Uptake by parathyroid cancer must be kept in mind as a cause of increased Tc-99m MIBI accumulation when a disease is in question in the thyroid or parathyroid gland.

  5. Liquid scintillation counting methodology for 99Tc analysis. A remedy for radiopharmaceutical waste

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Khan, Mumtaz; Um, Wooyong

    2015-08-13

    This paper presents a new approach for liquid scintillation counting (LSC) analysis of single-radionuclide samples containing appreciable organic or inorganic quench. This work offers better analytical results than existing LSC methods for technetium-99 ( 99gTc) analysis with significant savings in analysis cost and time. The method was developed to quantify 99gTc in environmental liquid and urine samples using LSC. Method efficiency was measured in the presence of 1.9 to 11,900 ppm total dissolved solids. The quench curve was proved to be effective in the case of spiked 99gTc activity calculation for deionized water, tap water, groundwater, seawater, and urine samples.more » Counting efficiency was found to be 91.66% for Ultima Gold LLT (ULG-LLT) and Ultima Gold (ULG). Relative error in spiked 99gTc samples was ±3.98% in ULG and ULG-LLT cocktails. Minimum detectable activity was determined to be 25.3 mBq and 22.7 mBq for ULG-LLT and ULG cocktails, respectively. A pre-concentration factor of 1000 was achieved at 100°C for 100% chemical recovery.« less

  6. Comparative in vivo evaluation of two novel 99mTc labelled bombesin derivatives

    NASA Astrophysics Data System (ADS)

    Gourni, Eleni; Bouziotis, Penelope; Zikos, Christos; Loudos, George; Xanthopoulos, Stavros; Fani, Melpomeni; Archimandritis, Spyridon C.; Varvarigou, Alexandra D.

    2006-12-01

    Bombesin (BN), a 14 amino acid peptide, is an analogue of human gastrin-releasing-peptide (GRP) that binds to GRP receptors (GRP-R) with high affinity and specificity. In addition to this physiological role, GRP, through its interaction with GRP-R, promotes tumour growth in a number of human cancer cell lines. The GRP receptors are over-expressed on a variety of human cancer cells. Aim of the present work is the study of two novels BN-like peptides, by investigating the radiochemical and radiopharmacological behaviour of their complexes with metals. The derivatives under study are: Gly-Gly-Cys-Aca-BN [2-14] where Aca: 6-amino-hexanoic acid. Pyroglutamic acid in the bombesin molecule has been replaced by the chemical group Gly-Gly-Cys-Aca, which bears an amino-acid combination capable of complexing a variety of radiometals. The other derivative under study is: Gly-Gly-Cys-Aca-BN [7-14]. This moiety of the peptide has been chosen because it has been proven to be a potent GRP agonist. The peptide derivatives were synthesized by SPPS, according to the Fmoc strategy and were identified by reverse phase high performance liquid chromatography (RP-HPLC). Radiolabelling with 99mTc was performed via the precursor 99mTc-gluconate. The stability of the radiolabelled species was examined with time. In vivo studies of the two 99mTc-labelled derivatives were performed, comparatively, in normal mice, attention being focused on GRP receptor-bearing organs, and in experimentally induced prostate cancer models. Experimental tumours were imaged in a small field-of-view animal gamma camera.

  7. Method for generating a crystalline {sup 99}MoO{sub 3} product and the isolation {sup 99m}Tc compositions therefrom

    DOEpatents

    Bennett, R.G.; Christian, J.D.; Kirkham, R.J.; Tranter, T.J.

    1998-09-01

    An improved method is described for producing {sup 99m}Tc compositions. {sup 100}Mo metal is irradiated with photons in a particle (electron) accelerator to produce {sup 99}Mo metal which is dissolved in a solvent. A solvated {sup 99}Mo product is then dried to generate a supply of {sup 99}MoO{sub 3} crystals. The crystals are thereafter heated at a temperature which will sublimate the crystals and form a gaseous mixture containing vaporized {sup 99m}TcO{sub 3} and vaporized {sup 99m}TcO{sub 2} but will not cause the production of vaporized {sup 99}MoO{sub 3}. The mixture is then combined with an oxidizing gas to generate a gaseous stream containing vaporized {sup 99m}Tc{sub 2}O{sub 7}. Next, the gaseous stream is cooled to a temperature sufficient to convert the vaporized {sup 99m}Tc{sub 2}O{sub 7} into a condensed {sup 99m}Tc-containing product. The product has high purity levels resulting from the use of reduced temperature conditions and ultrafine crystalline {sup 99}MoO{sub 3} starting materials with segregated {sup 99m}Tc compositions therein which avoid the production of vaporized {sup 99}MoO{sub 3} contaminants. 1 fig.

  8. Method for generating a crystalline .sup.99 MoO.sub.3 product and the isolation .sup.99m Tc compositions therefrom

    DOEpatents

    Bennett, Ralph G.; Christian, Jerry D.; Kirkham, Robert J.; Tranter, Troy J.

    1998-01-01

    An improved method for producing .sup.99m Tc compositions. .sup.100 Mo metal is irradiated with photons in a particle (electron) accelerator to produce .sup.99 Mo metal which is dissolved in a solvent. A solvated .sup.99 Mo product is then dried to generate a supply of .sup.99 MoO.sub.3 crystals. The crystals are thereafter heated at a temperature which will sublimate the crystals and form a gaseous mixture containing vaporized .sup.99m TcO.sub.3 and vaporized .sup.99m TcO.sub.2 but will not cause the production of vaporized .sup.99 MoO.sub.3. The mixture is then combined with an oxidizing gas to generate a gaseous stream containing vaporized .sup.99m Tc.sub.2 O.sub.7. Next, the gaseous stream is cooled to a temperature sufficient to convert the vaporized .sup.99m Tc.sub.2 O.sub.7 into a condensed .sup.99m Tc-containing product. The product has high purity levels resulting from the use of reduced temperature conditions and ultrafine crystalline .sup.99 MoO.sub.3 starting materials with segregated .sup.99m Tc compositions therein which avoid the production of vaporized .sup.99 MoO.sub.3 contaminants.

  9. Targeted functional imaging of estrogen receptors with 99mTc-GAP-EDL.

    PubMed

    Takahashi, Nobukazu; Yang, David J; Kohanim, Saady; Oh, Chang-Sok; Yu, Dong-Fang; Azhdarinia, Ali; Kurihara, Hiroaki; Zhang, Xiaochun; Chang, Joe Y; Kim, E Edmund

    2007-03-01

    To evaluate the feasibility of using (99m)Tc-glutamate peptide-estradiol in functional imaging of estrogen receptor-positive [ER(+)] diseases. 3-Aminoethyl estradiol (EDL) was conjugated to glutamate peptide (GAP) to yield GAP-EDL. Cellular uptake studies of (99m)Tc-GAP-EDL were conducted in ER(+) cell lines (MCF-7, 13762 and T47D). To demonstrate whether GAP-EDL increases MAP kinase activation, Western blot analysis of GAP-EDL was performed in 13762 cells. Biodistribution was conducted in nine rats with 13762 breast tumors at 0.5-4 h. Each rat was administered (99m)Tc-GAP-EDL. Two animal models (rats and rabbits) were created to ascertain whether tumor uptake of (99m)Tc-GAP-EDL was via an ER-mediated process. In the tumor model, breast tumor-bearing rats were pretreated with diethylstilbestrol (DES) 1 h prior to receiving (99m)Tc-GAP-EDL. In the endometriosis model, part of the rabbit uterine tissue was dissected and grafted to the peritoneal wall. The rabbit was administered with (99m)Tc-GAP-EDL. There was a 10-40% reduction in uptake of (99m)Tc-GAP-EDL in cells treated with DES or tamoxifen compared with untreated cells. Western blot analysis showed an ERK1/2 phosphorylation process with GAP-EDL. Biodistribution studies showed that tumor uptake and tumor-to-muscle count density ratio in (99m)Tc-GAP-EDL groups were significantly higher than those in (99m)Tc-GAP groups at 4 h. Among (99m)Tc-GAP-EDL groups, region of interest analysis of images showed that tumor-to muscle ratios were decreased in blocking groups. In the endometriosis model, the grafted uterine tissue could be visualized by (99m)Tc-GAP-EDL. Cellular or tumor uptake of (99m)Tc-GAP-EDL occurs via an ER-mediated process. (99m)Tc-GAP-EDL is a useful agent for imaging functional ER(+) disease.

  10. Evaluation of the protective effect of agmatine against cisplatin nephrotoxicity with 99mTc-DMSA renal scintigraphy and cystatin-C.

    PubMed

    Salihoglu, Yavuz Sami; Elri, Tarik; Gulle, Kanat; Can, Murat; Aras, Mustafa; Ozacmak, Hale Sayan; Cabuk, Mehmet

    2016-10-01

    The aim of the current study was to investigate whether agmatine (AGM) has a protective effect against cisplatin-induced nephrotoxicity. Thirty-two rats were randomly divided into four groups: (1) Saline (control); (2) Cisplatin (CDDP; 7.5 mg/kg intraperitoneally); (3) Agmatine (AGM; 10 mg/kg intraperitoneally); (4) Cisplatin plus agmatine (CDDP + AGM). Agmatine was given before and two consecutive days after cisplatin injection. All the animals underwent renal scintigraphy with 99mTc-DMSA. The levels of serum creatinine, cystatin C, and blood urea nitrogen (BUN) were measured in addition to examination of the tissue samples with light microscopy. Acute renal injury was assessed with biochemical analyses, scintigraphic imaging, and histopathological evaluation. In the cisplatin group, the levels of BUN, creatinine, and cystatin C were significantly higher than that of the controls. Histopathological examination showed remarkable damage of tubular and glomerular structures. Additionally, cisplatin caused markedly decreased renal 99mTc-DMSA uptake. AGM administration improved renal functions. Serum creatinine, BUN, and cystatin C levels had a tendency to normalize and, scintigraphic and histopathological findings showed significantly less evidence of renal toxicity than those observed in animals receiving cisplatin alone. Our data indicate that AGM has a protective effect against cisplatin-induced nephrotoxicity. Therefore, it may improve the therapeutic index of cisplatin. In addition, the early renal damage induced by cisplatin and protective effects of AGM against cisplatin nephrotoxicity was accurately demonstrated with 99mTc-DMSA renal scintigraphy.

  11. Comparison of LDPI to SPECT perfusion imaging using (99m)Tc-sestamibi and (99m)Tc-pyrophosphate in a murine ischemic hind limb model of neovascularization.

    PubMed

    Hendrikx, Geert; Vries, Mark H; Bauwens, Matthias; De Saint-Hubert, Marijke; Wagenaar, Allard; Guillaume, Joël; Boonen, Levinia; Post, Mark J; Mottaghy, Felix M

    2016-12-01

    We aimed to determine the accuracy of laser Doppler perfusion imaging (LDPI) in an animal model for hind limb ischemia. We used a murine (C57Bl/6 mice) ischemic hind limb model in which we compared LDPI with the clinically used (99m)Tc-sestamibi SPECT perfusion imaging (n = 7). In addition, we used the SPECT tracer (99m)Tc-pyrophosphate ((99m)Tc-PyP) to image muscular damage (n = 6). LDPI indicated a quick and prominent decrease in perfusion immediately after ligation, subsequently recovering to 21.9 and 25.2 % 14 days later in the (99m)Tc-sestamibi and (99m)Tc-PyP group, respectively. (99m)Tc-sestamibi SPECT scans also showed a quick decrease in perfusion. However, nearly full recovery was reached 7 days post ligation. Muscular damage, indicated by the uptake of (99m)Tc-PyP, was highest at day 3 and recovered to baseline levels at day 14 post ligation. Postmortem histology supported these findings, as a significantly increased collateral diameter was found 7 and 14 days after ligation and peak macrophage infiltration and TUNEL positivity was found on day 3 after ligation. Here, we indicate that LDPI strongly underestimates perfusion recovery in a hind limb model for profound ischemia.

  12. Efficacy of human serum butyrylcholinesterase against sarin vapor.

    PubMed

    Saxena, Ashima; Sun, Wei; Dabisch, Paul A; Hulet, Stanley W; Hastings, Nicholas B; Jakubowski, Edward M; Mioduszewski, Robert J; Doctor, Bhupendra P

    2008-09-25

    Human serum butyrylcholinesterase (Hu BChE) is currently under advanced development as a pretreatment drug for organophosphate (OP) poisoning in humans. It was shown to protect mice, rats, guinea pigs, and monkeys against multiple LD(50) challenges of OP nerve agents by i.v. or s.c. bolus injections. Since inhalation is the most likely route of exposure to OP nerve agents on the battlefield or in public places, the aim of this study was to evaluate the efficacy of Hu BChE against whole-body inhalation exposure to sarin (GB) vapor. Male Göttingen minipigs were subjected to one of the following treatments: (1) air exposure; (2) GB vapor exposure; (3) pretreatment with 3 mg/kg of Hu BChE followed by GB vapor exposure; (4) pretreatment with 6.5 mg/kg of Hu BChE followed by GB vapor exposure; (5) pretreatment with 7.5 mg/kg of Hu BChE followed by GB vapor exposure. Hu BChE was administered by i.m. injection, 24h prior to whole-body exposure to GB vapor at a concentration of 4.1 mg/m(3) for 60 min, a dose lethal to 99% of untreated exposed pigs (LCt99). EEG, ECG, and pupil size were monitored throughout exposure, and blood drawn from a surgically implanted jugular catheter before and throughout the exposure period, was analyzed for acetylcholinesterase (AChE) and BChE activities, and the amount of GB present in plasma. All animals exposed to GB vapor alone or pretreated with 3 or 6.5 mg/kg of Hu BChE, died following exposure to GB vapor. All five animals pretreated with 7.5 mg/kg of Hu BChE survived the GB exposure. The amount of GB bound in plasma was 200-fold higher compared to that from plasma of pigs that did not receive Hu BChE, suggesting that Hu BChE was effective in scavenging GB in blood. Additionally, pretreatment with 7.5 mg/kg of Hu BChE prevented cardiac abnormalities and seizure activity observed in untreated animals and those treated with lower doses of Hu BChE.

  13. Synthesis and evaluation of (99m)Tc chelate-conjugated bevacizumab.

    PubMed

    Camacho, Ximena; García, María Fernanda; Calzada, Victoria; Fernández, Marcelo; Porcal, Williams; Alonso, Omar; Gambini, Juan Pablo; Cabral, Pablo

    2013-03-01

    Vascular endothelial growth factor (VEGF) is one of the classic factors involved in tumor-induced angiognesis in several solid tumors. Bevacizumab, a monoclonal antibody against VEGF, can be used as an imaging tool in preclinical studies. The aim of this study was to radiolabel Bevacizumab with (99m)Tc and to evaluate in vivo its imaging properties in an adenocarcinoma animal model. For this purpose, Bevacizumab was derivatized with Suc-HYNIC as a bifunctional coupling agent. A mixture of Tricine/SnCl(2).2H(2)O was added to Bevacizumab-HYNIC and radiolabeled with (99m)TcO(4)(-). The radiochemical stability of the radiolabeled antibody was assessed. Biodistribution and scintigraphy imaging were performed in normal CD1 female mice and in spontaneous adenocarcinoma tumor bearing CD1 mice (n = 5). We demonstrated that 99mTc-HYNIC-Bevacizumab was stable. In vivo biodistribution studies revealed that tumor uptake of (99m)Tc-HYNIC-Bevacizumab was 1.37 ± 0.51% and 5.33 ± 2.13% at 4 and 24 h postinjection, respectively. Scintigraphy image studies showed tumor selective uptake of (99m)Tc-HYNIC-Bevacizumab in the tumor-bearing mice. We conclude that (99m)Tc-HYNIC-Bevacizumb has the potential to be used as a tracer for tumor imaging in preclinical studies.

  14. Direct production of 99mTc using a small medical cyclotron

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lapi, Suzanne

    This project describes an investigation towards the production of 99mTc with a small medical cyclotron. This endeavor addresses the current urgent problem of availability of 99mTc due to the ongoing production reactor failures and the upcoming Canadian reactor shut down. Currently, 99mTc is produced via nuclear fission using highly enriched uranium which is a concern due to nuclear proliferation risks. In addition to this, the United States is dependent solely on currently unreliable foreign sources of this important medical isotope. Clearly, a need exists to probe alternative production routes of 99mTc. In the first year, this project measured cross-sections andmore » production yields of potential pathways to 99mTc and associated radionuclidic impurities produced via these pathways using a small 15 MeV medical cyclotron. During the second and third years target systems for the production of 99mTc via the most promising reaction routes were developed and separation techniques for the isolation of 99mTc from the irradiated target material will be investigated. Systems for the recycling of the enriched target isotopes as well as automated target processing systems were examined in years four and five. This project has the potential to alleviate some of the current crisis in the medical community by developing a technique to produce 99mTc on location at a university hospital. This technology will be applicable at many other sites in the United States as many other similar, low energy (<20 MeV) cyclotrons (currently used for a few hours per day for the production of [ 18F]fluorodeoxyglucose) are available for production of 99mTc though this method, thus leading to job creation and preservation.« less

  15. Liver function assessment using 99mTc-GSA single-photon emission computed tomography (SPECT)/CT fusion imaging in hilar bile duct cancer: A retrospective study.

    PubMed

    Sumiyoshi, Tatsuaki; Shima, Yasuo; Okabayashi, Takehiro; Kozuki, Akihito; Hata, Yasuhiro; Noda, Yoshihiro; Kouno, Michihiko; Miyagawa, Kazuyuki; Tokorodani, Ryotaro; Saisaka, Yuichi; Tokumaru, Teppei; Nakamura, Toshio; Morita, Sojiro

    2016-07-01

    The objective of this study was to determine the utility of Tc-99m-diethylenetriamine-penta-acetic acid-galactosyl human serum albumin ((99m)Tc-GSA) single-photon emission computed tomography (SPECT)/CT fusion imaging for posthepatectomy remnant liver function assessment in hilar bile duct cancer patients. Thirty hilar bile duct cancer patients who underwent major hepatectomy with extrahepatic bile duct resection were retrospectively analyzed. Indocyanine green plasma clearance rate (KICG) value and estimated KICG by (99m)Tc-GSA scintigraphy (KGSA) and volumetric and functional rates of future remnant liver by (99m)Tc-GSA SPECT/CT fusion imaging were used to evaluate preoperative whole liver function and posthepatectomy remnant liver function, respectively. Remnant (rem) KICG (= KICG × volumetric rate) and remKGSA (= KGSA × functional rate) were used to predict future remnant liver function; major hepatectomy was considered unsafe for values <0.05. The correlation of remKICG and remKGSA with posthepatectomy mortality and morbidity was determined. Although remKICG and remKGSA were not significantly different (median value: 0.071 vs 0.075), functional rates of future remnant liver were significantly higher than volumetric rates (median: 0.54 vs 0.46; P < .001). Hepatectomy was considered unsafe in 17% and 0% of patients using remKICG and remKGSA, respectively. Postoperative liver failure and mortality did not occur in the patients for whom hepatectomy was considered unsafe based on remKICG. remKGSA showed a stronger correlation with postoperative prothrombin time activity than remKICG. (99m)Tc-GSA SPECT/CT fusion imaging enables accurate assessment of future remnant liver function and suitability for hepatectomy in hilar bile duct cancer patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. 99mTc-HMPAO SPECT of the brain in mild to moderate traumatic brain injury patients: compared with CT--a prospective study.

    PubMed

    Nedd, K; Sfakianakis, G; Ganz, W; Uricchio, B; Vernberg, D; Villanueva, P; Jabir, A M; Bartlett, J; Keena, J

    1993-01-01

    Single photon emission computed tomography (SPECT) with Technetium-99m hexamethyl propylenamine oxime (Tc-99m-HMPAO) was used in 20 patients with mild to moderate traumatic brain injury (TBI) to evaluate the effects of brain trauma on regional cerebral blood flow (rCBF). SPECT scan was compared with CT scan in 16 patients. SPECT showed intraparenchymal differences in rCBF more often than lesions diagnosed with CT scans (87.5% vs. 37.5%). In five of six patients with lesions in both modalities, the area of involvement was relatively larger on SPECT scans than on CT scans. Contrecoup changes were seen in five patients on SPECT alone, two patients with CT alone and one patient had contrecoup lesions on CT and SPECT. Of the eight patients (50%) with skull fractures, seven (43.7%) had rCBF findings on SPECT scan and five (31.3%) demonstrated decrease in rCBF in brain underlying the fracture. All these patients with fractures had normal brain on CT scans. Conversely, extra-axial lesions and fractures evident on CT did not visualize on SPECT, but SPECT demonstrated associated changes in rCBF. Although there is still lack of clinical and pathological correlation, SPECT appears to be a promising method for a more sensitive evaluation of axial lesions in patients with mild to moderate TBI.

  17. Localized chemistry of 99Tc in simulated low activity waste glass

    NASA Astrophysics Data System (ADS)

    Weaver, Jamie L.

    A priority of the United States Department of Energy (DOE) is to dispose of the nuclear waste accumulated in the underground tanks at the Hanford Nuclear Reservation in Richland, WA. Incorporation and stabilization of technetium (99Tc) from these tanks into vitrified waste forms is a concern to the waste glass community and DOE due to 99Tc's long half-life ( 2.13˙105 y), and its high mobility in the subsurface environment under oxidizing conditions. Working in collaboration with researchers at Pacific Northwest National Laboratory (PNNL) and other national laboratories, plans were formulated to obtain first-of-a-kind chemical structure determination of poorly understood and environmentally relevant technetium compounds that relate to the chemistry of the Tc in nuclear waste glasses. Knowledge of the structure and spectral signature of these compounds aid in refining the understanding of 99Tc incorporation into and release from oxide based waste glass. In this research a first-of-its kind mechanism for the behavior of 99Tc during vitrification is presented, and the structural role of Tc(VII) and (IV) in borosilicate waste glasses is readdressed.

  18. Comparative analysis of 99mTc-depreotide and 99mTc-EDDA/HYNIC-TOC thorax scintigrams acquired for the purpose of differential diagnosis of solitary pulmonary nodules.

    PubMed

    Płachcińska, Anna; Mikołajczak, Renata; Kozak, Józef; Rzeszutek, Katarzyna; Kuśmierek, Jacek

    2006-01-01

    Aiming at comparison of diagnostic efficacy of 2 radiopharmaceuticals: 99mTc-depreotide (Neospect, Amersham) and 99mTc-EDDA/HYNIC-Tyr3-octreotide (Tektrotyd, Polatom), in differentiation between malignant and benign etiology of solitary pulmonary nodules (SPNs), radionuclide studies with 2 radiotracers were performed in 18 patients. For both radiopharmaceuticals the same acquisition and processing protocols were applied. Studies were acquired with SPECT technique, after administration of 740 MBq of activity. Scintigrams were assessed visually, as: positive (+), equivocal (+/-) and negative (-). Additionally, uptake intensity of both radiotracers in nodules was assessed semiquantitatively, using a tumour-to-background ratio. Verification of scintigraphic results was based in 14 cases upon a pathological examination of tumour samples (histopathology) and in the remaining 4 - on clinical observation and bacteriological studies. Normal scintigrams obtained with both radiopharmaceuticals differed significantly. 99mTc-depreotide was markedly accumulated in spine, sternum, ribs and lungs (mean lung/heart ratio = 2.2). This accumulation was not observed on 99mTc- -EDDA/HYNIC-TOC scintigrams (mean lung/heart ratio = 0.7). In 6 patients a malignant etiology--lung cancer--was revealed (5--adenocarcinoma, 1--squamous cell) and the other 12 cases turned out to be benign (4 hamartomas, 3 tuberculomas, a tuberculous infiltrate, an alien body with inflammatory reaction, a hyperplasia of lymphatic tissue and 2 cases of unknown etiology, from which one had a stable size and the other resolved during a 6 month observation period). In all 6 cases of lung cancer positive results were obtained with both tracers. Moreover, in 2 patients metastases in mediastinum could be observed on scintigrams obtained with both radiopharmaceuticals. From among 12 cases of benign etiology 6 99mTc-depreotide scintigrams were true negative, 1--equivocal and 5--false positive, whereas 6 99m

  19. 99m Tc-HYNIC-(Ser)3 -J18 peptide: A radiotracer for non-small-cell lung cancer targeting.

    PubMed

    Shaghaghi, Zahra; Abedi, Seyed Mohammad; Hosseinimehr, Seyed Jalal

    2018-02-14

    Radiolabeled peptide could be a useful tool for the diagnosis of non-small-cell lung cancer (NSCLC). In this study, HYNIC-(Ser) 3 -J18 peptide was labeled with 99m Tc using EDDA/tricine as coligands. The in vitro and in vivo studies of this radiolabeled peptide were performed for cellular-specific binding and tumor targeting in A-549 cells and tumor-bearing mice, respectively. The high radiochemical purity was obtained and this radiolabeled peptide exhibited high stability in buffer and serum. The radiolabeled peptide showed high affinity for the A-549 cells with a dissociation constant value (K D ) of 4.4 ± 0.8 nm. The tumor-muscles ratios were 2.7 and 4.4 at 1 and 2 hr after injection of 99m Tc-(EDDA/tricine)-HYNIC-(Ser) 3 -J18 in tumor-bearing mice. The tumor uptake was decreased after preinjection with non-labeled peptide for this radiolabeled peptide in blocking experiment. The results of this study showed the 99m Tc-(EDDA/tricine)-(Ser) 3 -HYNIC-J18 peptide might be a promising radiolabeled peptide for NSCLC targeting. © 2018 John Wiley & Sons A/S.

  20. Dose calibrator linearity test: 99mTc versus 18F radioisotopes*

    PubMed Central

    Willegaignon, José; Sapienza, Marcelo Tatit; Coura-Filho, George Barberio; Garcez, Alexandre Teles; Alves, Carlos Eduardo Gonzalez Ribeiro; Cardona, Marissa Anabel Rivera; Gutterres, Ricardo Fraga; Buchpiguel, Carlos Alberto

    2015-01-01

    Objective The present study was aimed at evaluating the viability of replacing 18F with 99mTc in dose calibrator linearity testing. Materials and Methods The test was performed with sources of 99mTc (62 GBq) and 18F (12 GBq) whose activities were measured up to values lower than 1 MBq. Ratios and deviations between experimental and theoretical 99mTc and 18F sources activities were calculated and subsequently compared. Results Mean deviations between experimental and theoretical 99mTc and 18F sources activities were 0.56 (± 1.79)% and 0.92 (± 1.19)%, respectively. The mean ratio between activities indicated by the device for the 99mTc source as measured with the equipment pre-calibrated to measure 99mTc and 18F was 3.42 (± 0.06), and for the 18F source this ratio was 3.39 (± 0.05), values considered constant over the measurement time. Conclusion The results of the linearity test using 99mTc were compatible with those obtained with the 18F source, indicating the viability of utilizing both radioisotopes in dose calibrator linearity testing. Such information in association with the high potential of radiation exposure and costs involved in 18F acquisition suggest 99mTc as the element of choice to perform dose calibrator linearity tests in centers that use 18F, without any detriment to the procedure as well as to the quality of the nuclear medicine service. PMID:25798005

  1. Liquid chromatographic method for the simultaneous determination of captopril, piroxicam, and amlodipine in bulk drug, pharmaceutical formulation, and human serum by programming the detector.

    PubMed

    Sultana, Najma; Arayne, M Saeed; Ali, Saeeda Nadir

    2013-10-01

    A highly sensitive LC method with UV detection has been developed for the simultaneous determination of coadministered drugs captopril, piroxicam, and amlodipine in bulk drug, pharmaceutical formulations, and human serum at the isosbestic point (235 nm) and at individual λmax (220, 255, and 238 nm, respectively) by programming the detector with time to match the individual analyte's chromophore, which enhanced the sensitivity with linear range. The assay involved an isocratic elution of analytes on a Bondapak C18 (10 μm, 25 × 0.46 cm) column at ambient temperature using a mobile phase of methanol/water 80:20 at pH 2.9 and a flow rate of 1.0 mL/min. Linearity was found to be 0.25-25, 0.10-6.0, and 0.20-13.0 μg/mL with correlation coefficient >0.998 and detection limits of 7.39, 3.90, and 9.38 ng/mL, respectively, whereas calibration curves for wavelength-programmed analysis were 0.10-6.0, 0.04-2.56, and 0.10-10.0 μg/mL with correlation coefficient >0.998 and detection limits of 5.79, 2.68, and 3.87 ng/mL, respectively. All the validated parameters were in the acceptable range. The recovery of drugs was 99.32-100.39 and 98.65-101.96% in pharmaceutical formulation and human serum, respectively, at the isosbestic point and at individual λmax . This method is applicable for the analysis of drugs in bulk drug, tablets, serum, and in clinical samples without interference of excipients or endogenous serum components. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. (1→3)-β-D-glucan aptamers labeled with technetium-99m: Biodistribution and imaging in experimental models of bacterial and fungal infection.

    PubMed

    de Sousa Lacerda, Camila Maria; Ferreira, Iêda Mendes; Dos Santos, Sara Roberta; de Barros, André Luís Branco; Fernandes, Simone Odília; Cardoso, Valbert Nascimento; de Andrade, Antero Silva Ribeiro

    2017-03-01

    Acid nucleic aptamers are RNA or DNA oligonucleotides capable of binding to a target molecule with high affinity and selectivity. These molecules are promising tools in nuclear medicine. Many aptamers have been used as targeting molecule of radiopharmaceuticals in preclinical studies. (1→3)-β-D-glucans are the main structural cell wall components of fungi and some bacteria. In the present study two radiolabeled (1→3)-β-D-glucan aptamers (seq6 and seq30) were evaluated to identity infectious foci caused by fungal or bacterial cells. Aptamer labeling with 99m Tc was performed by the direct method and biodistribution studies were accomplished in Swiss mice (n=6) infected in the right thigh muscle with Staphylococcus aureus or Candida albicans. A 99m Tc radiolabeled library consisting of oligonucleotides with random sequences was used as control. There was a higher uptake of 99m Tc radiolabeled aptamers in the infected thigh than in the left thigh muscle (non-infected) in the S. aureus infected animals. The target/non-target ratios were 3.17±0.22 for seq6 and 2.66±0.10 for seq30. These ratios were statistically higher than the value (1.54±0.05) found for the radiolabeled library (control). With regard to biodistribution, no statistical difference was verified between aptamers and control uptakes in the infection foci in the C. albicans infected animals. The target/non-target ratios were 1.53±0.03, 1.64±0.12 and 1.08±0.02 for radiolabeled library, seq6 and seq30, respectively. Scintigraphic imaging of infected foci using radiolabeled aptamers was possible only for S. aureus infected mice. Seq6 and seq30 aptamers proved to be inefficient for diagnosis of C. albicans infection. Nevertheless, their applicability for diagnosis of S. aureus and other bacterial infections by scintigraphy should be further explored. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Detection and analysis of tupaia hepatocytes via mAbs against tupaia serum albumin.

    PubMed

    Liu, Xuan; Yuan, Lunzhi; Yuan, Quan; Zhang, Yali; Wu, Kun; Zhang, Tianying; Wu, Yong; Hou, Wangheng; Wang, Tengyun; Liu, Pingguo; Shih, James Wai Kuo; Cheng, Tong; Xia, Ningshao

    2016-05-20

    On the basis of its close phylogenetic relationship with primates, the development of Tupaia belangeri as an infection animal model and drug metabolism model could provide a new option for preclinical studies, especially in hepatitis virus research. As a replacement for primary human hepatocytes (PHHs), primary tupaia hepatocytes (PTHs) have been widely used. Similar to human serum albumin, tupaia serum albumin (TSA) is the most common liver synthesis protein and is an important biomarker for PTHs and liver function. However, no detection or quantitative method for TSA has been reported. In this study, mouse monoclonal antibodies (mAbs) 4G5 and 9H3 against TSA were developed to recognize PTHs, and they did not show cross-reactivity with serum albumin from common experimental animals, such as the mouse, rat, cow, rabbit, goat, monkey, and chicken. The two mAbs also exhibited good performance in fluorescence activated cell sorting (FACS) analysis and immunofluorescence (IF) detection of PTHs. A chemiluminescent enzyme immune assay method using the two mAbs, with a linear range from 96.89 pg/ml to 49,609.38 pg/ml, was developed for the quantitative detection of TSA. The mAbs and the CLEIA method provide useful tools for research on TSA and PTHs.

  4. Affinity precipitation of human serum albumin using a thermo-response polymer with an L-thyroxin ligand.

    PubMed

    Ding, Zhaoyang; Cao, Xuejun

    2013-12-17

    Affinity precipitation has been reported as a potential technology for the purification of proteins at the early stage of downstream processing. The technology could be achieved using reversible soluble-insoluble polymers coupled with an affinity ligand to purify proteins from large volumes of dilute solution material such as fermentation broths or plasma. In this study, a thermo-response polymer was synthesized using N-methylol acrylamide, N-isopropyl acrylamide and butyl acrylate as monomers. The molecular weight of the polymer measured by the viscosity method was 3.06 × 104 Da and the lower critical solution temperature (LCST) was 28.0°C.The recovery of the polymer above the LCST was over 95.0%. Human serum albumin (HSA) is the most abundant protein in the human serum system, and it has important functions in the human body. High purity HSA is required in pharmaceuticals. Safe and efficient purification is a crucial process during HSA production. A thermo-response polymer was synthesized and L-thyroxin immobilized on the polymer as an affinity ligand to enable affinity precipitation of HSA. The LCST of the affinity polymer was 31.0°C and the recovery was 99.6% of its original amount after recycling three times. The optimal adsorption condition was 0.02 M Tris-HCl buffer (pH 7.0) and the HSA adsorption capacity was 14.9 mg/g polymer during affinity precipitation. Circular dichroism spectra and a ForteBio Octet system were used to analyze the interactions between the affinity polymer and HSA during adsorption and desorption. The recovery of total HSA by elution with 1.0 mol/L NaSCN was 93.6%. When the affinity polymer was applied to purification of HSA from human serum, HSA could be purified to single-band purity according to SDS-PAGE. A thermo-response polymer was synthesized and L-thyroxin was attached to the polymer. Affinity precipitation was used to purify HSA from human serum.

  5. Affinity precipitation of human serum albumin using a thermo-response polymer with an L-thyroxin ligand

    PubMed Central

    2013-01-01

    Background Affinity precipitation has been reported as a potential technology for the purification of proteins at the early stage of downstream processing. The technology could be achieved using reversible soluble-insoluble polymers coupled with an affinity ligand to purify proteins from large volumes of dilute solution material such as fermentation broths or plasma. In this study, a thermo-response polymer was synthesized using N-methylol acrylamide, N-isopropyl acrylamide and butyl acrylate as monomers. The molecular weight of the polymer measured by the viscosity method was 3.06 × 104 Da and the lower critical solution temperature (LCST) was 28.0°C.The recovery of the polymer above the LCST was over 95.0%. Human serum albumin (HSA) is the most abundant protein in the human serum system, and it has important functions in the human body. High purity HSA is required in pharmaceuticals. Safe and efficient purification is a crucial process during HSA production. Results A thermo-response polymer was synthesized and L-thyroxin immobilized on the polymer as an affinity ligand to enable affinity precipitation of HSA. The LCST of the affinity polymer was 31.0°C and the recovery was 99.6% of its original amount after recycling three times. The optimal adsorption condition was 0.02 M Tris–HCl buffer (pH 7.0) and the HSA adsorption capacity was 14.9 mg/g polymer during affinity precipitation. Circular dichroism spectra and a ForteBio Octet system were used to analyze the interactions between the affinity polymer and HSA during adsorption and desorption. The recovery of total HSA by elution with 1.0 mol/L NaSCN was 93.6%. When the affinity polymer was applied to purification of HSA from human serum, HSA could be purified to single-band purity according to SDS-PAGE. Conclusion A thermo-response polymer was synthesized and L-thyroxin was attached to the polymer. Affinity precipitation was used to purify HSA from human serum. PMID:24341315

  6. From Conventional Radiotracer Tc-99(m) with Blue Dye to Indocyanine Green Fluorescence: A Comparison of Methods Towards Optimization of Sentinel Lymph Node Mapping in Early Stage Cervical Cancer for a Laparoscopic Approach.

    PubMed

    Buda, Alessandro; Papadia, Andrea; Zapardiel, Ignacio; Vizza, Enrico; Ghezzi, Fabio; De Ponti, Elena; Lissoni, Andrea Alberto; Imboden, Sara; Diestro, Maria Dolores; Verri, Debora; Gasparri, Maria Luisa; Bussi, Beatrice; Di Martino, Giampaolo; de la Noval, Begoña Diaz; Mueller, Michael; Crivellaro, Cinzia

    2016-09-01

    The credibility of sentinel lymph node (SLN) mapping is becoming increasingly more established in cervical cancer. We aimed to assess the sensitivity of SLN biopsy in terms of detection rate and bilateral mapping in women with cervical cancer by comparing technetium-99 radiocolloid (Tc-99(m)) and blue dye (BD) versus fluorescence mapping with indocyanine green (ICG). Data of patients with cervical cancer stage 1A2 to 1B1 from 5 European institutions were retrospectively reviewed. All centers used a laparoscopic approach with the same intracervical dye injection. Detection rate and bilateral mapping of ICG were compared, respectively, with results obtained by standard Tc-99(m) with BD. Overall, 76 (53 %) of 144 of women underwent preoperative SLN mapping with radiotracer and intraoperative BD, whereas 68 of (47 %) 144 patients underwent mapping using intraoperative ICG. The detection rate of SLN mapping was 96 % and 100 % for Tc-99(m) with BD and ICG, respectively. Bilateral mapping was achieved in 98.5 % for ICG and 76.3 % for Tc-99(m) with BD; this difference was statistically significant (p < 0.0001). The fluorescence SLN mapping with ICG achieved a significantly higher detection rate and bilateral mapping compared to standard radiocolloid and BD technique in women with early stage cervical cancer. Nodal staging with an intracervical injection of ICG is accurate, safe, and reproducible in patients with cervical cancer. Before replacing lymphadenectomy completely, the additional value of fluorescence SLN mapping on both perioperative morbidity and survival should be explored and confirmed by ongoing controlled trials.

  7. A technetium-labeled monoclonal antibody for imaging metastatic melanoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Frytak, S.; Creagan, E.T.; Brown, M.L.

    1991-04-01

    Twenty patients with histologically proven metastatic melanoma were scanned with a 99mtechnetium ({sup 99}mTc)-labeled melanoma antibody to determine the detection rate of known malignant lesions and to evaluate the antibody's ability to discover occult metastases. Isotope localization in different organs was as follows: liver 100%, bone 100%, subcutaneous lesions 80%, lymph nodes 54%, and lung 33%. Four unsuspected bone lesions and 16 occult subcutaneous lesions were found. False positive lesions were noted in two instances--one benign thyroid adenoma, and one arthritic bone lesion. One patient developed an atypical serum sickness reaction with a rash and arthralgias that responded rapidly tomore » treatment. The {sup 99}mTc antimelanoma antibody is a safe and effective method to detect metastatic melanoma. It has potential use for screening newly diagnosed melanomas that carry an increased risk of recurrence.« less

  8. Posaconazole in Human Serum: a Greater Pharmacodynamic Effect than Predicted by the Non-Protein-Bound Serum Concentration ▿

    PubMed Central

    Lignell, Anders; Löwdin, Elisabeth; Cars, Otto; Chryssanthou, Erja; Sjölin, Jan

    2011-01-01

    It is generally accepted that only the unbound fraction of a drug is pharmacologically active. Posaconazole is an antifungal agent with a protein binding of 98 to 99%. Taking into account the degree of protein binding, plasma levels in patients, and MIC levels of susceptible strains, it can be assumed that the free concentration of posaconazole sometimes will be too low to exert the expected antifungal effect. The aim was therefore to test the activity of posaconazole in serum in comparison with that of the calculated unbound concentrations in protein-free media. Significant differences (P < 0.05) from the serum control were found at serum concentrations of posaconazole of 1.0 and 0.10 mg/liter, with calculated free concentrations corresponding to 1× MIC and 0.1× MIC, respectively, against one Candida lusitaniae strain selected for proof of principle. In RPMI 1640, the corresponding calculated unbound concentration of 0.015 mg/liter resulted in a significant effect, whereas that of 0.0015 mg/liter did not. Also, against seven additional Candida strains tested, there was an effect of the low posaconazole concentration in serum, in contrast to the results in RPMI 1640. Fluconazole, a low-grade-protein-bound antifungal, was used for comparison at corresponding concentrations in serum and RPMI 1640. No effect was observed at the serum concentration, resulting in a calculated unbound concentration of 0.1× MIC. In summary, there was a substantially greater pharmacodynamic effect of posaconazole in human serum than could be predicted by the non-protein-bound serum concentration. A flux from serum protein-bound to fungal lanosterol 14α-demethylase-bound posaconazole is suggested. PMID:21502622

  9. Second-trimester maternal serum marker screening: maternal serum alpha-fetoprotein, beta-human chorionic gonadotropin, estriol, and their various combinations as predictors of pregnancy outcome.

    PubMed

    Yaron, Y; Cherry, M; Kramer, R L; O'Brien, J E; Hallak, M; Johnson, M P; Evans, M I

    1999-10-01

    We evaluated the value of all 3 common biochemical serum markers, maternal serum alpha-fetoprotein, beta-human chorionic gonadotropin, and unconjugated estriol, and combinations thereof as predictors of pregnancy outcome. A total of 60,040 patients underwent maternal serum screening. All patients had maternal serum alpha-fetoprotein measurements; beta-human chorionic gonadotropin was measured in 45,565 patients, and 24,504 patients had determination of all 3 markers, including unconjugated estriol. The incidences of various pregnancy outcomes were evaluated according to the serum marker levels by using clinically applied cutoff points. In confirmation of previous observations, increased maternal serum alpha-fetoprotein levels (>2.5 multiples of the median) were found to be significantly associated with pregnancy-induced hypertension, miscarriage, preterm delivery, intrauterine growth restriction, intrauterine fetal death, oligohydramnios, and abruptio placentae. Increased beta-human chorionic gonadotropin levels (>2.5 multiples of the median [MoM]) were significantly associated with pregnancy-induced hypertension, miscarriage, preterm delivery, and intrauterine fetal death. Finally, decreased unconjugated estriol levels (<0.5 MoM) were found to be significantly associated with pregnancy-induced hypertension, miscarriage, intrauterine growth restriction, and intrauterine fetal death. As with increased second-trimester maternal serum alpha-fetoprotein levels, increased serum beta-human chorionic gonadotropin and low unconjugated estriol levels are significantly associated with adverse pregnancy outcomes. These are most likely attributed to placental dysfunction. Multiple-marker screening can be used not only for the detection of fetal anomalies and aneu-ploidy but also for detection of high-risk pregnancies.

  10. Synthesis of 99mTc-nimotuzumab with tricarbonyl ion: in vitro and in vivo studies.

    PubMed

    Garcia, Maria Fernanda; Camacho, Ximena; Calzada, Victoria; Fernandez, Marcelo; Porcal, Williams; Alonso, Omar; Gambini, Juan Pablo; Cabral, Pablo

    2012-01-01

    The Epidermal growth factor receptor (EGFR) family plays an important role in carcinogenesis. CIMAher® (Nimotuzumab), is a humanized monoclonal antibody, which recognizes EGFR with high affinity. The aim of this work was to perform the direct labeling of Nimotuzumab with [99mTc(CO)3(H2O)3]+ as precursor and to evaluate its labeling conditions, in vitro and in vivo stability and biodistrution in normal C57 BL/6J mice. 99mTc(CO3)-Nimotuzumab labeling yields were up to 90%. More than 90% of the complex remained intact after 24 h of incubation with L-Histidine (1/300 molar ratio). Biodistribution studies in normal mice were also performed. Inmunoreactivity was confirmed by cell binding assays with A431cells. These results encourage the evaluation of the potential role of 99mTc(CO)3-Nimotuzumab as a novel tumor-avid radiotracer for targeting in vivo EGFR expression.

  11. Ion Exchange Distribution Coefficient Tests and Computer Modeling at High Ionic Strength Supporting Technetium Removal Resin Maturation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, Charles A.; Hamm, L. Larry; Smith, Frank G.

    2014-12-19

    The primary treatment of the tank waste at the DOE Hanford site will be done in the Waste Treatment and Immobilization Plant (WTP) that is currently under construction. The baseline plan for this facility is to treat the waste, splitting it into High Level Waste (HLW) and Low Activity Waste (LAW). Both waste streams are then separately vitrified as glass and poured into canisters for disposition. The LAW glass will be disposed onsite in the Integrated Disposal Facility (IDF). There are currently no plans to treat the waste to remove technetium, so its disposition path is the LAW glass. Duemore » to the water solubility properties of pertechnetate and long half-life of 99Tc, effective management of 99Tc is important to the overall success of the Hanford River Protection Project mission. To achieve the full target WTP throughput, additional LAW immobilization capacity is needed, and options are being explored to immobilize the supplemental LAW portion of the tank waste. Removal of 99Tc, followed by off-site disposal, would eliminate a key risk contributor for the IDF Performance Assessment (PA) for supplemental waste forms, and has potential to reduce treatment and disposal costs. Washington River Protection Solutions (WRPS) is developing some conceptual flow sheets for supplemental LAW treatment and disposal that could benefit from technetium removal. One of these flowsheets will specifically examine removing 99Tc from the LAW feed stream to supplemental immobilization. To enable an informed decision regarding the viability of technetium removal, further maturation of available technologies is being performed. This report contains results of experimental ion exchange distribution coefficient testing and computer modeling using the resin SuperLig ® 639 a to selectively remove perrhenate from high ionic strength simulated LAW. It is advantageous to operate at higher concentration in order to treat the waste stream without dilution and to minimize the volume of the

  12. Increased breast density correlates with the proliferation-seeking radiotracer (99m)Tc(V)-DMSA uptake in florid epithelial hyperplasia and in mixed ductal carcinoma in situ with invasive ductal carcinoma but not in pure invasive ductal carcinoma or in mild epithelial hyperplasia.

    PubMed

    Papantoniou, Vassilios; Valsamaki, Pipitsa; Sotiropoulou, Evangelia; Tsaroucha, Angeliki; Tsiouris, Spyridon; Sotiropoulou, Maria; Marinopoulos, Spyridon; Kounadi, Evangelia; Karianos, Theodore; Fothiadaki, Athina; Archontaki, Aikaterini; Syrgiannis, Konstantinos; Ptohis, Nikolaos; Makris, Nikolaos; Limouris, Georgios; Antsaklis, Aris

    2011-10-01

    The purpose of this study was to assess the relationship of mammographic breast density (BD) and cell proliferation/focal adhesion kinase activation-seeking radiotracer technetium 99m pentavalent dimercaptosuccinic acid (99mTc(V)-DMSA) uptake in women with different breast histologies, that is, mild epithelial hyperplasia (MEH), florid epithelial hyperplasia (FEH), mixed ductal carcinoma in situ with invasive ductal carcinoma (DCIS + IDC), and pure IDC. Fifty-five women with histologically confirmed mammary pathologies were submitted preoperatively to mammography and 99mTc(V)-DMSA scintimammography. The percentage and intensity of 99mTc(V)-DMSA uptake and the percentage of BD were calculated by computer-assisted methods and compared (t-test) between the breast pathologies. In breasts with increased BD, FEH and DCIS + IDC were found. On the contrary, pure IDC and MEH were identified in breasts with significantly lower BD values. In breasts with increased 99mTc(V)-DMSA area and intensity of uptake, FEH was the main lesion found compared to all other histologies. Linear regression analysis between BD and 99mTc(V)-DMSA uptake area and intensity revealed significant coefficients of correlation (r  =  .689, p < .001 and r  =  .582, p < .001, respectively). Increased BD correlates with the presence of FEH and mixed DCIS + IDC but not with pure IDC or MEH. Its close relationship to 99mTc(V)-DMSA, which also showed an affinity to FEH, indicates that stromal microenvironment may constitute a specific substrate leading to progression to different subtypes of cancerous lesions originating from different pathways.

  13. Preclinical evaluation of (99m)Tc labeled chondroitin sulfate for monitoring of cartilage degeneration in osteoarthritis.

    PubMed

    Sobal, Grazyna; Velusamy, Kavitha; Kosik, Siegfried; Menzel, Johannes; Hacker, Marcus; Pagitz, Maximilian

    2016-06-01

    In previous in-vitro and ex-vivo studies we proved the specific uptake of (99m)Tc radiolabeled chondroitin sulfate (CS) in human articular cartilage. As a logical next step for the clinical use for imaging osteoarthritis we investigated in-vivo uptake of (99m)TcCS in dogs. The radiolabeling of CS Condrosulf (IBSA, Lugano, Switzerland) was performed using 25mg of CS and 20-40MBq/kg body weight of (99m)Tc by means of the tin method. In-vivo uptake of (99m)TcCS was evaluated in dogs (n=12, castrated males, 4-9years, with 15-51kg body weight). 6 healthy dogs served as controls and 6 with clinical and radiological signs of osteoarthritis in the carpal, elbow, and tarsal joint were examined. The tracer was i.v. injected into the external cephalic vein. The uptake was monitored after 2, 4, 6 and 24h in healthy and osteoarthritic dogs using a planar gamma camera by regional planar or whole body ventral and dorsal acquisition. For whole body scintigraphy animals were under general anesthesia, for planar under sedation only. In healthy control dogs we did not detect any specific uptake of (99m)TcCS in the cartilage. In contrast, in the diseased dogs suffering from osteoarthritis a significant, specific, persistent uptake between 4 and 6h in tarsal, carpal and cubital joints was documented. Median target (joint) to background (mid antebrachium) ratio (T/B) in the OA joints after 4, 6, and 24h was significantly higher than in healthy controls. Target to background ratio using soft tissue as a background (T/S) a similar significantly higher than in healthy controls. In all osteoarthritic joints we found a significant positive correlation (r=0.8, n=20) between grade of disease (I-III) and T/B. When matching radiographic (X ray) changes in osteoarthritic joints (grade II and III) we found also a maximal uptake of (99m)TcCS at the specific anatomical site of highest cartilage degeneration. None of the dogs experienced any side effects. These results suggest that (99m)TcCS might

  14. Monoanionic 99mTc-tricarbonyl-aminopolycarboxylate complexes with uncharged pendant groups: Radiosynthesis and evaluation as potential renal tubular tracers.

    PubMed

    Lipowska, Malgorzata; Klenc, Jeffrey; Jarkas, Nashwa; Marzilli, Luigi G; Taylor, Andrew T

    2017-04-01

    charged pendant carboxyl group previously thought to be essential for rapid renal extraction, 99m Tc(CO) 3 (ADA), 99m Tc(CO) 3 (HDA) and 99m Tc(CO) 3 (FEDA), exhibit pharmacokinetics in rats comparable to those of 99m Tc(CO) 3 (NTA) and 131 I-OIH. Furthermore, these encouraging results in rats warrant evaluation of this new tracer type in humans. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Quantitative studies of bone in postmenopausal women using (18)F-fluoride and (99m)Tc-methylene diphosphonate.

    PubMed

    Blake, Glen M; Park-Holohan, So-Jin; Fogelman, Ignac

    2002-03-01

    Quantitative radionuclide studies of bone using the short-lived tracers (18)F-fluoride and (99m)Tc-methylene diphosphonate (MDP) are an alternative method to biochemical markers of bone turnover for investigating the dynamic state of the skeleton. In this study we evaluated their use to quantify bone turnover in women receiving antiresorptive therapy compared with that of untreated control subjects. The patients were 69 healthy postmenopausal women. Twenty-six women were receiving hormone replacement therapy (HRT) and 43 were untreated age-matched control subjects. After bolus injection of (18)F-fluoride (1 MBq), (99m)Tc-MDP (1 MBq), (51)Cr-ethylenediaminetetraacetic acid (3 MBq), and (125)I-labeled human serum albumin (0.25 MBq), multiple blood samples and urine collections were taken between 0 and 4 h. The clearance to bone mineral K(bone) was first evaluated using the area under the plasma concentration curve (AUC) on the assumption that the rate constant k(4) for the outflow of tracer from bone was negligibly small. AUC values of K(bone) were then compared with those found using a compartmental model method that allowed k(4) to be fitted as a free parameter. Using the AUC method the mean plus minus SD for K(bone) for the 2 tracers were: (18)F-fluoride, 61.8 plus minus 12.0 mL center dot min(-1) (HRT group) versus 67.2 plus minus 12.6 mL center dot min(-1) (control group) (P = 0.045); and (99m)Tc-MDP, 40.3 plus minus 8.2 mL center dot min(-1) (HRT group) versus 44.2 plus minus 7.6 mL center dot min(-1) (control group) (P = 0.024). Values for the 2 tracers in individual patients were moderately well correlated (r = 0.76; P < 0.001). Using the compartmental model method, k(4) for (18)F-fluoride was shown to lie in the range 0--0.0025 min(-1) with a best-fit value of 0.0018 min(-1). Values of K(bone) determined using k(4) = 0.0018 min(-1) were highly correlated with the AUC values (r = 0.989; SEE = 2.05 mL center dot min(-1)) with numeric values that were larger by

  16. Effect of caricapryl-99 seed alkaloid extract on the serum levels of sex hormones and pituitary gonadotrophins in male albino rats.

    PubMed

    Udoh, P B; Udoh, F V; Umoren, E B; James, U W; Okeke, C P; Agwu, B

    2009-06-01

    Activity of alkaloid extract of caricapryl-99 seeds [Carica papaya Linn seeds] on the serum levels of steroid hormones was studied in adult male albino rats. Three tolerated doses obtained from the graph of percentage toxicity [10, 50 and 150 mg/kg] were separately administered orally, daily for three days to three groups of male rats [n=5] while group four of 5 rats received the vehicle [corn oil] as control. The results showed that 10 mg/kg/d caused increase serum levels of FSH and estrogen but decrease in the serum levels of LH and testosterone compared to control; 50 mg/kg/d elevated the serum levels of FSH, estrogen but inhibited testosterone; while 150 mg/kg/d pretreatments caused a significant decrease [p<0.01] in the serum levels of FSH, LH and testosterone. The results suggest that caricapryl-99 treatment inhibited the serum level of the androgen, testosterone which might result in a male infertility.

  17. Tc-99m TRODAT uptake in an osteoid tumor of clivus.

    PubMed

    Taywade, Sameer; Tripathi, Madhavi; Tandon, Vivek; Das, Chandan Jyoti; Damle, Nishikant Avinash; Shamim, Shamim Ahmed; Thukral, Parul; Bal, Chandrasekhar

    2016-01-01

    Tc-99m TRODAT is cocaine analog and binds to the dopamine transporter in vivo . Tc-99m TRODAT single-photon emission computed tomography/computed tomography. (SPECT/CT) is useful for demonstrating presynaptic dopaminergic dysfunction in patients with Parkinsonism. However, few reports have shown extrastriatal uptake of Tc-99m TRODAT. We present the case of a 67-year-old male who underwent Tc-99m TRODAT SPECT/CT for evaluation of Parkinsonism. In addition to tracer binding in the striatum, tracer uptake was noted in an osteoid tumor of the clivus. Integrated SPECT/CT enabled precise localization and characterization of the extrastriatal site of tracer binding and emphasizes the importance of such coincidental findings.

  18. Breaking America’s Dependence on Foreign…Molybdenum

    PubMed Central

    Einstein, Andrew J.

    2009-01-01

    Brief Unstructured Abstract Approximately 9 million nuclear cardiology studies performed each year in the United States employ technetium-99m, which is produced from the decay of molybdenum-99. The fragility of the worldwide technetium-99m supply chain has been underscored by current shortages caused by an unplanned shutdown of Europe’s largest reactor. The majority of the United States’ supply derives from a reactor in Canada nearing the end of its lifespan, whose planned replacements have been recently cancelled. In this article, the clinical importance of technetium-99m and our tenuous dependence on foreign supply of Molybdenum is addressed. PMID:19356583

  19. Indirect electrochemical detection for total bile acids in human serum.

    PubMed

    Zhang, Xiaoqing; Zhu, Mingsong; Xu, Biao; Cui, Yue; Tian, Gang; Shi, Zhenghu; Ding, Min

    2016-11-15

    Bile acids level in serum is a useful index for screening and diagnosis of hepatobiliary diseases. As bile acids concentration is closely related to the degree of hepatobiliary diseases, detecting it is a vital factor to understand the stage of the diseases. The prevalent determination for bile acids is the enzymatic cycling method which has low sensitivity while reagent-consuming. It is desirable to develop a new method with lower cost and higher sensitivity. An indirect electrochemical detection (IED) for bile acids in human serum was established using the screen printed carbon electrode (SPCE). Since bile acids do not show electrochemical signals, they were converted to 3-ketosteroids by 3-α-hydroxysteroid dehydrogenase (3α-HSD) in the presence of nicotinamide adenine dinucleotide (NAD(+)), which was reduced to NADH. NADH could then be oxidized on the surface of SPCE, generating a signal that was used to calculate the total bile acids (TBA) concentration. A good linear calibration for TBA was obtained at the concentration range from 5.00μM to 400μM in human serum. Both the precisions and recoveries were sufficient to be used in a clinical setting. The TBA concentrations in 35 human serum samples by our IED method didn't show significant difference with the result by enzymatic cycling method, using the paired t-test. Moreover, our IED method is reagent-saving, sensitive and cost-effective. Copyright © 2016. Published by Elsevier B.V.

  20. Effects of 99mTc-TRODAT-1 drug template on image quantitative analysis

    PubMed Central

    Yang, Bang-Hung; Chou, Yuan-Hwa; Wang, Shyh-Jen; Chen, Jyh-Cheng

    2018-01-01

    99mTc-TRODAT-1 is a type of drug that can bind to dopamine transporters in living organisms and is often used in SPCT imaging for observation of changes in the activity uptake of dopamine in the striatum. Therefore, it is currently widely used in studies on clinical diagnosis of Parkinson’s disease (PD) and movement-related disorders. In conventional 99mTc-TRODAT-1 SPECT image evaluation, visual inspection or manual selection of ROI for semiquantitative analysis is mainly used to observe and evaluate the degree of striatal defects. However, these methods are dependent on the subjective opinions of observers, which lead to human errors, have shortcomings such as long duration, increased effort, and have low reproducibility. To solve this problem, this study aimed to establish an automatic semiquantitative analytical method for 99mTc-TRODAT-1. This method combines three drug templates (one built-in SPECT template in SPM software and two self-generated MRI-based and HMPAO-based TRODAT-1 templates) for the semiquantitative analysis of the striatal phantom and clinical images. At the same time, the results of automatic analysis of the three templates were compared with results from a conventional manual analysis for examining the feasibility of automatic analysis and the effects of drug templates on automatic semiquantitative analysis results. After comparison, it was found that the MRI-based TRODAT-1 template generated from MRI images is the most suitable template for 99mTc-TRODAT-1 automatic semiquantitative analysis. PMID:29543874

  1. Synthesis and Evaluation of Tricarbonyl 99mTc-Labeled 2-(4-Chloro)phenyl-imidazo[1,2-a]pyridine Analogs as Novel SPECT Imaging Radiotracer for TSPO-Rich Cancer

    PubMed Central

    Choi, Ji Young; Iacobazzi, Rosa Maria; Perrone, Mara; Margiotta, Nicola; Cutrignelli, Annalisa; Jung, Jae Ho; Park, Do Dam; Moon, Byung Seok; Denora, Nunzio; Kim, Sang Eun; Lee, Byung Chul

    2016-01-01

    The 18-kDa translocator protein (TSPO) levels are associated with brain, breast, and prostate cancer progression and have emerged as viable targets for cancer therapy and imaging. In order to develop highly selective and active ligands with a high affinity for TSPO, imidazopyridine-based TSPO ligand (CB256, 3) was prepared as the precursor. 99mTc- and Re-CB256 (1 and 2, respectively) were synthesized in high radiochemical yield (74.5% ± 6.4%, decay-corrected, n = 5) and chemical yield (65.6%) by the incorporation of the [99mTc(CO)3(H2O)3]+ and (NEt4)2[Re(CO)3Br3] followed by HPLC separation. Radio-ligand 1 was shown to be stable (>99%) when incubated in human serum for 4 h at 37 °C with a relatively low lipophilicity (logD = 2.15 ± 0.02). The rhenium-185 and -187 complex 2 exhibited a moderate affinity (Ki = 159.3 ± 8.7 nM) for TSPO, whereas its cytotoxicity evaluated on TSPO-rich tumor cell lines was lower than that observed for the precursor. In vitro uptake studies of 1 in C6 and U87-MG cells for 60 min was found to be 9.84% ± 0.17% and 7.87% ± 0.23% ID, respectively. Our results indicated that 99mTc-CB256 can be considered as a potential new TSPO-rich cancer SPECT imaging agent and provides the foundation for further in vivo evaluation. PMID:27399688

  2. Bioinorganic Activity of Technetium Radiopharmaceuticals.

    ERIC Educational Resources Information Center

    Pinkerton, Thomas C.; And Others

    1985-01-01

    Technetium radiopharmaceuticals are diagnostic imaging agents used in the field of nuclear medicine to visualize tissues, anatomical structures, and metabolic disorders. Bioavailability of technetium complexes, thyroid imaging, brain imaging, kidney imaging, imaging liver function, bone imaging, and heart imaging are the major areas discussed. (JN)

  3. Technetium recovery from high alkaline solution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nash, Charles A.

    2016-07-12

    Disclosed are methods for recovering technetium from a highly alkaline solution. The highly alkaline solution can be a liquid waste solution from a nuclear waste processing system. Methods can include combining the solution with a reductant capable of reducing technetium at the high pH of the solution and adding to or forming in the solution an adsorbent capable of adsorbing the precipitated technetium at the high pH of the solution.

  4. Low-activity 124I-PET/low-dose CT versus 99mTc-pertechnetate planar scintigraphy or 99mTc-pertechnetate single-photon emission computed tomography of the thyroid: a pilot comparison.

    PubMed

    Darr, Andreas M; Opfermann, Thomas; Niksch, Tobias; Driesch, Dominik; Marlowe, Robert J; Freesmeyer, Martin

    2013-10-01

    The standard thyroid functional imaging method, 99mTc-pertechnetate (99mTc-PT) planar scintigraphy, has technical drawbacks decreasing its sensitivity in detecting nodules or anatomical pathology. 124I-PET, lacking these disadvantages and allowing simultaneous CT, may have greater sensitivity for these purposes. We performed a blinded pilot comparison of 124I-PET(/CT) versus 99mTc-PT planar scintigraphy or its cross-sectional enhancement, 99mTc-PT single-photon emission CT (SPECT), in characterizing the thyroid gland with benign disease. Twenty-one consecutive adults with goiter underwent low-activity (1 MBq/0.027 mCi) 124I-PET/low-dose (30 mAs) CT, 99mTc-PT planar scintigraphy, and 99mTc-PT-SPECT. Endpoints included the numbers of “hot spots” with/without central photopenia and “cold spots” detected, the proportion of these lesions with morphological correlates, the mean volume and diameter of visualized nodules, and the number of cases of lobus pyramidalis or retrosternal thyroid tissue identified. 124I-PET detected significantly more “hot spots” with/without central photopenia (P < 0.001), significantly more nodules (P < 0.001), and more “cold spots” than did 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT, including all lesions seen on the 99mTc-PT modalities. Ultrasonographic correlates were found for all nodules visualized on all 3 modalities and 92.5% of nodules seen only on 124I-PET. Nodules discernible only on 124I-PET had significantly smaller mean volume or diameter (P < 0.001) than did those visualized on 99mTc-PT planar scintigraphy or 99mTc-PT-SPECT. 124I-PET(/CT) identified significantly more patients with a lobus pyramidalis (P < 0.001) or retrosternal thyroid tissue (P < 0.05). 124I-PET(/CT) may provide superior imaging of benign thyroid disease compared to planar or cross-sectional 99mTc-PT scintigraphy.

  5. Isolation of human anti-serum albumin Fab antibodies with an extended serum-half life.

    PubMed

    Kang, Hyeon-Ju; Kim, Hye-Jin; Cha, Sang-Hoon

    2016-01-01

    The serum albumin (SA) has been exploited to generate long-acting biotherapeutics by taking advantage of the FcRn-mediated recycling mechanism in a direct or an indirect way. Since Fab fragments have been proven to be clinically safe for human usage, we assumed that human anti-SA Fab antibodies could have a great potential as a carrier molecule to extend the serum half-life of therapeutic proteins. We, herein, had attempted to isolate anti-SA Fab antibodies from HuDVFab-8L antibody library via a phage display technology, and identified eight discrete human Fab antibodies. One of the Fab antibodies, SL335, showed the strongest binding reactivity to human SA with nM range of affinity at both pH 6 and pH 7.4, and cross-reacted to SAs from various species including rat, mouse, canine and monkey. The in vivo pharmacokinetic assay using a rat model indicated that SL335 has approximately 10 fold longer serum half-life and 26 to 44-fold increase in AUC0 → ∞ compared to the negative control Fab molecule in both intravenous and subcutaneous administrations. Knowing that Fabs have proven to be safe in clinics for a long time, SL335 seems to have a great potential in generating long-acting protein drugs by tagging effector molecules with either chemical conjugation or genetic fusion. Copyright © 2015 Elsevier B.V. All rights reserved.

  6. Measuring hepatic functional reserve using low temporal resolution Gd-EOB-DTPA dynamic contrast-enhanced MRI: a preliminary study comparing galactosyl human serum albumin scintigraphy with indocyanine green retention.

    PubMed

    Saito, Kazuhiro; Ledsam, Joseph; Sourbron, Steven; Hashimoto, Tsuyoshi; Araki, Yoichi; Akata, Soichi; Tokuuye, Koichi

    2014-01-01

    To investigate if tracer kinetic modelling of low temporal resolution dynamic contrast-enhanced (DCE) MRI with Gd-EOB-DTPA could replace technetium-99 m galactosyl human serum albumin (GSA) single positron emission computed tomography (SPECT) and indocyanine green (ICG) retention for the measurement of liver functional reserve. Twenty eight patients awaiting liver resection for various cancers were included in this retrospective study that was approved by the institutional review board. The Gd-EOB-DTPA MRI sequence acquired five images: unenhanced, double arterial phase, portal phase, and 4 min after injection. Intracellular contrast uptake rate (UR) and extracellular volume (Ve) were calculated from DCE-MRI, along with the ratio of GSA radioactivity of liver to heart-plus-liver and per cent of cumulative uptake from 15-16 min (LHL15 and LU15, respectively) from GSA-scintigraphy. ICG retention at 15 min, Child-Pugh cirrhosis score (CPS) and postoperative Inuyama fibrosis criteria were also recorded. Statistical analysis was with Spearman rank correlation analysis. Comparing MRI parameters with the reference methods, significant correlations were obtained for UR and LHL15, LU15, ICG15 (all 0.4-0.6, P < 0.05); UR and CPS (-0.64, P < 0.001); Ve and Inuyama (0.44, P < 0.05). Measures of liver function obtained by routine Gd-EOB-DTPA DCE-MRI with tracer kinetic modelling may provide a suitable method for the evaluation of liver functional reserve. • Magnetic resonance imaging (MRI) provides new methods of measuring hepatic functional reserve. • DCE-MRI with Gd-EOB-DTPA offers the possibility of replacing scintigraphy. • The analysis method can be used for preoperative liver function evaluation.

  7. Highly specific preoperative selection of solitary parathyroid adenoma cases in primary hyperparathyroidism by quantitative image analysis of the early-phase Technetium-99m sestamibi scan.

    PubMed

    Kim, DaeHee; Rhodes, Jeffrey A; Hashim, Jeffrey A; Rickabaugh, Lawrence; Brams, David M; Pinkus, Edward; Dou, Yamin

    2018-06-07

    Highly specific preoperative localizing test is required to select patients for minimally invasive parathyroidectomy (MIP) in lieu of traditional four-gland exploration. We hypothesized that Tc-99m sestamibi scan interpretation incorporating numerical measurements on the degree of asymmetrical activity from bilateral thyroid beds can be useful in localizing single adenoma for MIP. We devised a quantitative interpretation method for Tc-99m sestamibi scan based on the numerically graded asymmetrical activity on early phase. The numerical ratio value of each scan was obtained by dividing the number of counts from symmetrically drawn regions of interest (ROI) over bilateral thyroid beds. The final pathology and clinical outcome of 109 patients were used to perform receiver operating curve (ROC) analysis. Receiver operating curve analysis revealed the area under the curve (AUC) was calculated to be 0.71 (P = 0.0032), validating this method as a diagnostic tool. The optimal cut-off point for the ratio value with maximal combined sensitivity and specificity was found with corresponding sensitivity of 67.9% (56.5-77.2%, 95% CI) and specificity of 75.0% (52.8-91.8%, 95% CI). An additional higher cut-off with higher specificity with minimal possible sacrifice on sensitivity was also selected, yielding sensitivity of 28.6% (18.8-38.6%, 95% CI) and specificity of 90.0% (69.6-98.8%, 95% CI). Our results demonstrated that the more asymmetrical activity on the initial phase, the more successful it is to localize a single parathyroid adenoma on sestamibi scans. Using early-phase Tc-99m sestamibi scan only, we were able to select patients for minimally invasive parathyroidectomy with 90% specificity. © 2018 The Royal Australian and New Zealand College of Radiologists.

  8. Rhenium and technetium tricarbonyl complexes of 1,4-Substituted pyridyl-1,2,3-triazole bidentate 'click' ligands conjugated to a targeting RGD peptide.

    PubMed

    Connell, Timothy U; Hayne, David J; Ackermann, Uwe; Tochon-Danguy, Henri J; White, Jonathan M; Donnelly, Paul S

    2014-04-01

    New 1,4-substituted pyridyl-1,2,3-triazole ligands with pendent phenyl isothiocyanate functional groups linked to the heterocycle through a short methylene or longer polyethylene glycol spacers were prepared and conjugated to a peptide containing the arginine-glycine-aspartic acid peptide motif. Rhenium and technetium carbonyl complexes, [M(CO)3 L(x) (py)](+) (where M = Re(I) or (99m) Tc(I) ; L(x)  = 1,4-substituted pyridyl-1,2,3-triazole ligands and py = pyridine) were prepared. One rhenium complex has been characterized by X-ray crystallography, and the luminescent properties of [M(CO)3 L(x) (py)](+) are reported. Copyright © 2013 John Wiley & Sons, Ltd.

  9. Controlling Pu behavior on Titania: Implications for LEU Fission-Based Mo-99 Production

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Youker, Amanda J.; Brown, M. Alex; Heltemes, Thad A.

    Molybdenum-99 is the parent isotope of the most widely used isotope, technetium-99m, in all diagnostic nuclear medicine procedures. Due to proliferation concerns associated with the use of highly enriched uranium (HEU), the preferred method of fission-based Mo-99 production uses low enriched uranium (LEU) targets. Using LEU versus HEU for Mo-99 production produces similar to 30 times more Pu-239, due to neutron capture on U-238 to produce Np-239, which ultimately decays to Pu-239 (t(1/2) = 24,110 yr). Argonne National Laboratory is supporting a potential US Mo-99 producer in their efforts to produce Mo-99 from an LEU solution. In order to mitigatemore » the generation of large volumes of greater-than-class-C (GTCC) low level waste (Pu-239 concentrations greater than 1 nCi/g), we have focused our efforts on the separation chemistry of Pu and Mo with a titania sorbent in sulfate media. Results from batch and column experiments show that temperature and acid wash concentration can be used to control Pu behavior on titania.« less

  10. A Tc-99m-labeled long chain fatty acid derivative for myocardial imaging.

    PubMed

    Magata, Yasuhiro; Kawaguchi, Takayoshi; Ukon, Misa; Yamamura, Norio; Uehara, Tomoya; Ogawa, Kazuma; Arano, Yasushi; Temma, Takashi; Mukai, Takahiro; Tadamura, Eiji; Saji, Hideo

    2004-01-01

    C-11- and I-123-labeled long chain fatty acid derivatives have been reported as useful radiopharmaceuticals for the estimation of myocardial fatty acid metabolism. We have reported that Tc-99m-labeled N-[[[(2-mercaptoethyl)amino]carbonyl]methyl]-N-(2-mercaptoethyl)-6-aminohexanoic acid ([(99m)Tc]MAMA-HA), a medium chain fatty acid derivative, is metabolized by beta-oxidation in the liver and that the MAMA ligand is useful for attaching to the omega-position of fatty acid derivatives as a chelating group for Tc-99m. On the basis of these findings, we focused on developing a Tc-99m-labeled long chain fatty acid derivative that reflected fatty acid metabolism in the myocardium. In this study, we synthesized a dodecanoic acid derivative, MAMA-DA, and a hexadecanoic acid derivative, MAMA-HDA, and performed radiolabeling and biodistribution studies. [(99m)Tc]MAMA-DA and [(99m)Tc]MAMA-HDA were prepared using a ligand-exchange reaction. Biodistribution studies were carried out in normal mice and rats. Then, a high initial uptake of Tc-99m was observed, followed by a rapid clearance from the heart. The maximum heart/blood ratio was 3.6 at 2 min postinjection of [(99m)Tc]MAMA-HDA. These kinetics were similar to those with postinjection of p-[(125)I]iodophenylpentadecanoic acid. Metabolite analysis showed [(99m)Tc]MAMA-HDA was metabolized by beta-oxidation in the body. In conclusion, [(99m)Tc]MAMA-HDA is a promising compound as a long chain fatty acid analogue for estimating beta-oxidation of fatty acid in the heart.

  11. Process for extracting technetium from alkaline solutions

    DOEpatents

    Moyer, Bruce A.; Sachleben, Richard A.; Bonnesen, Peter V.

    1995-01-01

    A process for extracting technetium values from an aqueous alkaline solution containing at least one alkali metal hydroxide and at least one alkali metal nitrate, the at least one alkali metal nitrate having a concentration of from about 0.1 to 6 molar. The solution is contacted with a solvent consisting of a crown ether in a diluent for a period of time sufficient to selectively extract the technetium values from the aqueous alkaline solution. The solvent containing the technetium values is separated from the aqueous alkaline solution and the technetium values are stripped from the solvent.

  12. Synthesis, 99m Tc-labeling, and preliminary biological evaluation of DTPA-melphalan conjugates.

    PubMed

    Wang, Jianjun; Yang, Wenjiang; Xue, Jinquan; Zhang, Yanhua; Liu, Yu

    2017-12-01

    Melphalan (MFL) is a typical nitrogen mustard for the treatment of many types of cancer. For the purpose to develop novel 99m Tc-labeled tumor imaging agents with SPECT, MFL was directly labeled by 99m Tc using diethylene triamine pentacetate acid (DTPA) as bifunctional chelating agent. The novel ligands were successfully synthesized by conjugation of DTPA to MFL to get monosubstituted DTPA-MFL and bis-substituted DTPA-2MFL. Radiolabeling was performed in high yield to get 99m Tc-DTPA-MFL and 99m Tc-DTPA-2MFL, respectively, which were hydrophilic and stable at room temperature. The high initial tumor uptake with retention, good tumor/muscle ratios, and satisfactory scintigraphic images suggested the potential of 99m Tc-DTPA-MFL and 99m Tc-DTPA-2MFL for tumor imaging. However, the slow normal tissue clearance would be a great obstacle. Further modification on the linker and/or 99m Tc-chelate to improve the tumor targeting efficacy and in vivo kinetic profiles is currently in progress. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Design of an X -band electron linear accelerator dedicated to decentralized 99Mo/99mTc supply: From beam energy selection to yield estimation

    NASA Astrophysics Data System (ADS)

    Jang, Jaewoong; Yamamoto, Masashi; Uesaka, Mitsuru

    2017-10-01

    The most frequently used radionuclide in diagnostic nuclear medicine, 99mTc, is generally obtained by the decay of its parent radionuclide, 99Mo. Recently, concerns have been raised over shortages of 99Mo/99mTc, owing to aging of the research reactors which have been supplying practically all of the global demand for 99Mo in a centralized fashion. In an effort to prevent such 99Mo/99mTc supply disruption and, furthermore, to ameliorate the underlying instability of the centralized 99Mo/99mTc supply chain, we designed an X -band electron linear accelerator which can be distributed over multiple regions, whereby 99Mo/99mTc can be supplied with improved accessibility. The electron beam energy was designed to be 35 MeV, at which an average beam power of 9.1 kW was calculated by the following beam dynamics analysis. Subsequent radioactivity modeling suggests that 11 of the designed electron linear accelerators can realize self-sufficiency of 99Mo/99mTc in Japan.

  14. Serum or breast milk immunoglobulins mask the self-reactivity of human natural IgG antibodies.

    PubMed

    Djoumerska-Alexieva, Iglika; Manoylov, Iliyan; Dimitrov, Jordan D; Tchorbanov, Andrey

    2014-04-01

    B cells producing IgG antibodies specific to a variety of self- or foreign antigens are a normal constituent of the immune system of all healthy individuals. These naturally occurring IgG antibodies are found in the serum, external secretions, and pooled human immunoglobulin preparations. They bind with low affinity to antigens, which can also be targets for pathologic autoantibodies. An enhancement of naturally occurring IgG autoantibody activity was observed after treatment of human IgG molecules with protein-destabilizing agents. We have investigated the interactions of human immunoglobulins that were obtained from serum or from breast milk of healthy individuals or IVIg with human liver antigens. Proteins from an individual serum or milk were isolated by two methods, one of which included exposure to low pH and the other did not. Purified serum, mucosal IgM, IgA, and the fraction containing immunoglobulin G F(ab')2 fragments each inhibited the binding of a single donor or pooled IgG to human liver antigens. Our study presents findings regarding the role of the breast milk or serum antibodies in blocking the self-reactivity of IgG antibodies. It supports the suggestion that not IVIg only, but also the pooled human IgM and IgA might possess a potent beneficial immunomodulatory activity in autoimmune patients. © 2013 APMIS. Published by John Wiley & Sons Ltd.

  15. Breaking America's dependence on imported molybdenum.

    PubMed

    Einstein, Andrew J

    2009-03-01

    Approximately 9 million nuclear cardiology studies performed each year in the U.S. use technetium-99m, which is produced from the decay of molybdenum-99. The fragility of the worldwide technetium-99m supply chain has been underscored by current shortages caused by an unplanned shutdown of Europe's largest reactor. The majority of the U.S. supply derives from a reactor in Canada that is nearing the end of its lifespan and whose planned replacements have been cancelled recently. In this article, the clinical importance of technetium-99m and our tenuous dependence on the foreign supply of molybdenum are addressed, along with potential measures that may be taken to ensure that America's supply chain remains unbroken.

  16. Redox-dependent solubility of technetium in low activity waste glass

    NASA Astrophysics Data System (ADS)

    Soderquist, Chuck Z.; Schweiger, Michael J.; Kim, Dong-Sang; Lukens, Wayne W.; McCloy, John S.

    2014-06-01

    The solubility of technetium was measured in a Hanford low activity waste (LAW) glass simulant, to investigate the extent that technetium solubility controls the incorporation of technetium into LAW glass. A series of LAW glass samples, spiked with 500-6000 ppm of Tc as potassium pertechnetate, were melted at 1000 °C in sealed fused quartz ampoules. Technetium solubility was determined in the quenched bulk glass to be 2000-2800 ppm, with slightly reducing conditions due to choice of milling media resulting in reductant contamination and higher solubility. The chemical form of technetium obtained by X-ray absorption near edge spectroscopy is mainly isolated, octahedrally-coordinated Tc(IV), with a minority of Tc(VII) in some glasses and TcO2 in two glasses. The concentration and speciation of technetium depends on glass redox and amount of technetium added. Salts formed at the top of higher technetium loaded glasses during the melt. The results of this study show that technetium solubility should not be a factor in technetium retention during melting of Hanford LAW glass.

  17. Glucagon-Like Peptide-1 Receptor Imaging with [Lys (40) (Ahx-HYNIC- (99 m) Tc/EDDA)NH 2 ]-Exendin-4 for the Diagnosis of Recurrence or Dissemination of Medullary Thyroid Cancer: A Preliminary Report.

    PubMed

    Pach, D; Sowa-Staszczak, A; Jabrocka-Hybel, A; Stefańska, A; Tomaszuk, M; Mikołajczak, R; Janota, B; Trofimiuk-Müldner, M; Przybylik-Mazurek, E; Hubalewska-Dydejczyk, A

    2013-01-01

    Introduction. Epidemiological studies on medullary thyroid cancer (MTC) have shown that neither a change in stage at diagnosis nor improvement in survival has occurred during the past 30 years. In patients with detectable serum calcitonin and no clinically apparent disease, a careful search for local recurrence, and nodal or distant metastases, should be performed. Conventional imaging modalities will not show any disease until basal serum calcitonin is at least 150 pg/mL. The objective of the study was to present the first experience with labelled glucagon-like peptide-1 (GLP-1) analogue [Lys(40)(Ahx-HYNIC-(99m)Tc/EDDA)NH2]-exendin-4 in the visualisation of MTC in humans. Material and Method. Four patients aged 22-74 years (two with sporadic and two with MEN2 syndrome-related disseminated MTC) were enrolled in the study. In all patients, GLP-1 receptor imaging was performed. Results. High-quality images were obtained in all patients. All previously known MTC lesions have been confirmed in GLP-1 scintigraphy. Moreover, one additional liver lesion was detected in sporadic MTC male patient. Conclusions. GLP-1 receptor imaging with [Lys(40)(Ahx-HYNIC-(99m)Tc/EDDA)NH2]-exendin-4 is able to detect MTC lesions. GLP-1 scintigraphy can serve as a confirmatory test in MTC patients, in whom other imaging procedures are inconsistent.

  18. Glucagon-Like Peptide-1 Receptor Imaging with [Lys40(Ahx-HYNIC-99mTc/EDDA)NH2]-Exendin-4 for the Diagnosis of Recurrence or Dissemination of Medullary Thyroid Cancer: A Preliminary Report

    PubMed Central

    Pach, D.; Sowa-Staszczak, A.; Jabrocka-Hybel, A.; Stefańska, A.; Tomaszuk, M.; Mikołajczak, R.; Janota, B.; Trofimiuk-Müldner, M.; Przybylik-Mazurek, E.; Hubalewska-Dydejczyk, A.

    2013-01-01

    Introduction. Epidemiological studies on medullary thyroid cancer (MTC) have shown that neither a change in stage at diagnosis nor improvement in survival has occurred during the past 30 years. In patients with detectable serum calcitonin and no clinically apparent disease, a careful search for local recurrence, and nodal or distant metastases, should be performed. Conventional imaging modalities will not show any disease until basal serum calcitonin is at least 150 pg/mL. The objective of the study was to present the first experience with labelled glucagon-like peptide-1 (GLP-1) analogue [Lys40(Ahx-HYNIC-99mTc/EDDA)NH2]-exendin-4 in the visualisation of MTC in humans. Material and Method. Four patients aged 22–74 years (two with sporadic and two with MEN2 syndrome-related disseminated MTC) were enrolled in the study. In all patients, GLP-1 receptor imaging was performed. Results. High-quality images were obtained in all patients. All previously known MTC lesions have been confirmed in GLP-1 scintigraphy. Moreover, one additional liver lesion was detected in sporadic MTC male patient. Conclusions. GLP-1 receptor imaging with [Lys40(Ahx-HYNIC-99mTc/EDDA)NH2]-exendin-4 is able to detect MTC lesions. GLP-1 scintigraphy can serve as a confirmatory test in MTC patients, in whom other imaging procedures are inconsistent. PMID:23606839

  19. Fast liquid chromatographic-tandem mass spectrometric method using mixed-mode phase chromatography and solid phase extraction for the determination of 12 mono-hydroxylated brominated diphenyl ethers in human serum.

    PubMed

    Petropoulou, Syrago-Styliani E; Duong, Wendy; Petreas, Myrto; Park, June-Soo

    2014-08-22

    Hydroxylated polybrominated diphenyl ethers (OH-PBDEs) are formed from the oxidative metabolism of polybrominated diphenyl ethers (PBDEs) in humans, rats and mice, but their quantitation in human blood and other matrices with liquid chromatography-mass spectrometric techniques has been a challenge. In this study, a novel analytical method was developed and validated using only 250 μL of human serum for the quantitation of twelve OH-PBDEs, fully chromatographically separated in a 15 min analytical run. This method includes two novel approaches: an enzymatic hydrolysis procedure and a chromatographic separation using a mixed mode chromatography column. The enzymatic hydrolysis (EH) was found critical for 4'-OH-BDE17, which was not detectable without it. For the sample clean up, a solid phase extraction protocol was developed and validated for the extraction of the 12 congeners from human serum. In addition, for the first time baseline resolution of two components was achieved that correspond to a single peak previously identified as 6'-OH-BDE99. The method was validated for linearity, accuracy, precision, matrix effects, limit of quantification, limit of detection, sample stability and overall efficiency. Recoveries (absolute and relative) ranged from 66 to 130% with relative standard deviations <21% for all analytes. Limit of detection and quantitation ranged from 4 to 90 pg mL(-1) and 6-120 pg mL(-1), respectively, with no carry over effects. This method was applied in ten commercially available human serum samples from the general US population. The mean values of the congeners detected in all samples are 4'-OH-BDE17 (34.2 pg mL(-1)), 4-OH-BDE42 (33.9 pg mL(-1)), 5-OH-BDE47 (17.5 pg mL(-1)) and 4'-OH-BDE49 (12.4 pg mL(-1)). Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Evaluation of (99)  (m)TcN-MPO as a new myocardial perfusion imaging agent in normal dogs and in an acute myocardial infarction canine model: comparison with (99)  (m)Tc-sestamibi.

    PubMed

    Bu, Lihong; Li, Renfei; Jin, Zhongnan; Wen, Xiaofei; Liu, Shuang; Yang, Baofeng; Shen, Baozhong; Chen, Xiaoyuan

    2011-02-01

    (99)  (m)TcN-MPO ([(99)  (m)TcN(mpo)(PNP5)](+): mpo = 2-mercaptopyridine oxide and PNP5 = N-ethoxyethyl-N,N-bis[2-(bis(3-methoxypropyl)phosphino)ethyl]amine) is a cationic (99)  (m)Tc-nitrido complex, which has favorable biodistribution and myocardial uptake with rapid liver clearance in Sprague Dawley rats. The objective of this study was to compare the biodistribution and pharmacokinetics of (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi in normal dogs, and to evaluate the potential of (99)  (m)TcN-MPO as a myocardial perfusion agent in canines with acute myocardial infarction. Five normal mongrel dogs were injected intravenously with (99)  (m)TcN-MPO. Venous blood samples were collected via a femoral vein catheter at 0.5, 1, 2, 3, 4, 5, 10, 20, 30, 40, 60, and 90 min post-injection (p.i.). Anterior-posterior planar images were acquired by γ-camera at 10, 20, 30, 60, 90, and 120 min p.i. Regions of interest (ROIs) were drawn around the heart, liver, and lungs. The heart/liver and heart/lung ratios were calculated by dividing the mean counts in heart ROI by the mean counts in the liver and lung ROI, respectively. For comparison, (99)  (m)Tc-sestamibi was also evaluated in the same five dogs. The interval period between the two examinations was 1 week to eliminate possible interference between these two radiotracers. In addition, single positron emission computed tomography (SPECT) images in the canine infarct model were collected 24 h after myocardial infarction at 30 and 60 min after the administration of (99)  (m)TcN-MPO (n = 4) or (99)  (m)Tc-Sestamibi (n = 4). It was found that (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi displayed very similar blood clearance characteristics during the first 90 min p.i. Both (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi had a rapid blood clearance with less than 50% of initial radioactivity remaining at 1 min and less than 5% at 30 min p.i. (99)  (m)TcN-MPO and (99)  (m)Tc-Sestamibi both showed good