Sample records for temperature dew-point temperature

  1. Automatic dew-point temperature sensor.

    PubMed

    Graichen, H; Rascati, R; Gonzalez, R R

    1982-06-01

    A device is described for measuring dew-point temperature and water vapor pressure in small confined areas. The method is based on the deposition of water on a cooled surface when at dew-point temperature. A small Peltier module lowers the temperature of two electrically conductive plates. At dew point the insulating gap separating the plates becomes conductive as water vapor condenses. Sensors based on this principle can be made small and rugged and can be used for measuring directly the local water vapor pressure. They may be installed within a conventional ventilated sweat capsule used for measuring water vapor loss from the skin surface. A novel application is the measurement of the water vapor pressure gradients across layers of clothing worn by an exercising subject.

  2. Accurate dew-point measurement over a wide temperature range using a quartz crystal microbalance dew-point sensor

    NASA Astrophysics Data System (ADS)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Buyng-Il

    2008-11-01

    Quartz crystal microbalance (QCM) dew-point sensors are based on frequency measurement, and so have fast response time, high sensitivity and high accuracy. Recently, we have reported that they have the very convenient attribute of being able to distinguish between supercooled dew and frost from a single scan through the resonant frequency of the quartz resonator as a function of the temperature. In addition to these advantages, by using three different types of heat sinks, we have developed a QCM dew/frost-point sensor with a very wide working temperature range (-90 °C to 15 °C). The temperature of the quartz surface can be obtained effectively by measuring the temperature of the quartz crystal holder and using temperature compensation curves (which showed a high level of repeatability and reproducibility). The measured dew/frost points showed very good agreement with reference values and were within ±0.1 °C over the whole temperature range.

  3. Investigation of the dew-point temperature scale maintained at the MIKES

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    1999-01-01

    For the investigation of the dew-point temperature scale realized by the MIKES primary dew-point generator, a two-pressure generator and a dew-point indicator based on condensation in a cooled coil were constructed and tested. In addition, a chilled mirror hygrometer was validated by means of an uncertainty analysis. The comparison of these systems was focused on the dew-point temperature range from 0957-0233/10/1/010/img1 to 0957-0233/10/1/010/img2 but measurements were made up to 0957-0233/10/1/010/img3. The generator systems were compared using a dew-point comparator based on two relative humidity sensors. According to the results of the comparisons, the differences between the measurement systems were less than 0957-0233/10/1/010/img4, while the expanded uncertainty of the MIKES generator was between 0957-0233/10/1/010/img5 and 0957-0233/10/1/010/img6. The uncertainty of the other systems was from 0957-0233/10/1/010/img7 to 0957-0233/10/1/010/img8. It was concluded that the dew-point temperature scale was not dependent on the realization method.

  4. Comparison of dew point temperature estimation methods in Southwestern Georgia

    Treesearch

    Marcus D. Williams; Scott L. Goodrick; Andrew Grundstein; Marshall Shepherd

    2015-01-01

    Recent upward trends in acres irrigated have been linked to increasing near-surface moisture. Unfortunately, stations with dew point data for monitoring near-surface moisture are sparse. Thus, models that estimate dew points from more readily observed data sources are useful. Daily average dew temperatures were estimated and evaluated at 14 stations in...

  5. Pressure-Drop Considerations in the Characterization of Dew-Point Transfer Standards at High Temperatures

    NASA Astrophysics Data System (ADS)

    Mitter, H.; Böse, N.; Benyon, R.; Vicente, T.

    2012-09-01

    During calibration of precision optical dew-point hygrometers (DPHs), it is usually necessary to take into account the pressure drop induced by the gas flow between the "point of reference" and the "point of use" (mirror or measuring head of the DPH) either as a correction of the reference dew-point temperature or as part of the uncertainty estimation. At dew-point temperatures in the range of ambient temperature and below, it is sufficient to determine the pressure drop for the required gas flow, and to keep the volumetric flow constant during the measurements. In this case, it is feasible to keep the dry-gas flow into the dew-point generator constant or to measure the flow downstream the DPH at ambient temperature. In normal operation, at least one DPH in addition to the monitoring DPH are used, and this operation has to be applied to each instrument. The situation is different at high dew-point temperatures up to 95 °C, the currently achievable upper limit reported in this paper. With increasing dew-point temperatures, the reference gas contains increasing amounts of water vapour and a constant dry-gas flow will lead to a significant enhanced volume flow at the conditions at the point of use, and therefore, to a significantly varying pressure drop depending on the applied dew-point temperature. At dew-point temperatures above ambient temperature, it is also necessary to heat the reference gas and the mirror head of the DPH sufficiently to avoid condensation which will additionally increase the volume flow and the pressure drop. In this paper, a method is provided to calculate the dry-gas flow rate needed to maintain a known wet-gas flow rate through a chilled mirror for a range of temperature and pressures.

  6. Estimation of dew point temperature using neuro-fuzzy and neural network techniques

    NASA Astrophysics Data System (ADS)

    Kisi, Ozgur; Kim, Sungwon; Shiri, Jalal

    2013-11-01

    This study investigates the ability of two different artificial neural network (ANN) models, generalized regression neural networks model (GRNNM) and Kohonen self-organizing feature maps neural networks model (KSOFM), and two different adaptive neural fuzzy inference system (ANFIS) models, ANFIS model with sub-clustering identification (ANFIS-SC) and ANFIS model with grid partitioning identification (ANFIS-GP), for estimating daily dew point temperature. The climatic data that consisted of 8 years of daily records of air temperature, sunshine hours, wind speed, saturation vapor pressure, relative humidity, and dew point temperature from three weather stations, Daego, Pohang, and Ulsan, in South Korea were used in the study. The estimates of ANN and ANFIS models were compared according to the three different statistics, root mean square errors, mean absolute errors, and determination coefficient. Comparison results revealed that the ANFIS-SC, ANFIS-GP, and GRNNM models showed almost the same accuracy and they performed better than the KSOFM model. Results also indicated that the sunshine hours, wind speed, and saturation vapor pressure have little effect on dew point temperature. It was found that the dew point temperature could be successfully estimated by using T mean and R H variables.

  7. Temperature distribution model for the semiconductor dew point detector

    NASA Astrophysics Data System (ADS)

    Weremczuk, Jerzy; Gniazdowski, Z.; Jachowicz, Ryszard; Lysko, Jan M.

    2001-08-01

    The simulation results of temperature distribution in the new type silicon dew point detector are presented in this paper. Calculations were done with use of the SMACEF simulation program. Fabricated structures, apart from the impedance detector used to the dew point detection, contained the resistive four terminal thermometer and two heaters. Two detector structures, the first one located on the silicon membrane and the second one placed on the bulk materials were compared in this paper.

  8. An Investigation of the Relation Between Contact Thermometry and Dew-Point Temperature Realization

    NASA Astrophysics Data System (ADS)

    Benyon, R.; Böse, N.; Mitter, H.; Mutter, D.; Vicente, T.

    2012-09-01

    Precision optical dew-point hygrometers are the most commonly used transfer standards for the comparison of dew-point temperature realizations at National Metrology Institutes (NMIs) and for disseminating traceability to calibration laboratories. These instruments have been shown to be highly reproducible when properly used. In order to obtain the best performance, the resistance of the platinum resistance thermometer (PRT) embedded in the mirror is usually measured with an external, traceable resistance bridge or digital multimeter. The relation between the conventional calibration of miniature PRTs, prior to their assembly in the mirrors of state-of-the-art optical dew-point hygrometers and their subsequent calibration as dew-point temperature measurement devices, has been investigated. Standard humidity generators of three NMIs were used to calibrate hygrometers of different designs, covering the dew-point temperature range from -75 °C to + 95 °C. The results span more than a decade, during which time successive improvements and modifications were implemented by the manufacturer. The findings are presented and discussed in the context of enabling the optimum use of these transfer standards and as a basis for determining contributions to the uncertainty in their calibration.

  9. Global Validation of MODIS Atmospheric Profile-Derived Near-Surface Air Temperature and Dew Point Estimates

    NASA Astrophysics Data System (ADS)

    Famiglietti, C.; Fisher, J.; Halverson, G. H.

    2017-12-01

    This study validates a method of remote sensing near-surface meteorology that vertically interpolates MODIS atmospheric profiles to surface pressure level. The extraction of air temperature and dew point observations at a two-meter reference height from 2001 to 2014 yields global moderate- to fine-resolution near-surface temperature distributions that are compared to geographically and temporally corresponding measurements from 114 ground meteorological stations distributed worldwide. This analysis is the first robust, large-scale validation of the MODIS-derived near-surface air temperature and dew point estimates, both of which serve as key inputs in models of energy, water, and carbon exchange between the land surface and the atmosphere. Results show strong linear correlations between remotely sensed and in-situ near-surface air temperature measurements (R2 = 0.89), as well as between dew point observations (R2 = 0.77). Performance is relatively uniform across climate zones. The extension of mean climate-wise percent errors to the entire remote sensing dataset allows for the determination of MODIS air temperature and dew point uncertainties on a global scale.

  10. Trends in temperature and dew point at the summit of Mount Washington, New Hampshire, 1935-2004.

    NASA Astrophysics Data System (ADS)

    Grant, A. N.; Pszenny, A. A.; Fischer, E. V.

    2005-05-01

    Dry and wet bulb temperatures from sling psychrometer measurements taken every six hours from 1935 to 2004 at the summit of Mount Washington, located at 44 °16'N, 71 °18'W, 1914 m ASL have recently been digitized. Annual temperature has increased by 0.3°C, and annual dew point has decreased by 0.4°C over this 70-year period. Synoptic temperature has increased most in spring and winter, changing by 1.0°C and 0.5°C, respectively, while it has decreased slightly in summer and fall. Dew point has decreased in fall, summer, and winter, 0.9°C, 0.5°C, and 0.4°C respectively, and increased by 0.1°C in spring. Preliminary analysis suggests that some of the larger trends in winter and spring may be statistically significant; results of Monte Carlo simulations will be reported. Changes in dew point may be attributed to two factors. Decreasing dew points are expected if the temperature increases but the amount of water vapor present stays the same. Alternatively, lower dew points could be indicative of the presence of drier air. Other dew point climatologies of the continental United States for the second half of the century have shown mixed results, with increased dew points evident at some stations, decreased dew points at others, and no clear regional patterns.

  11. Temporal trends in United States dew point temperatures

    NASA Astrophysics Data System (ADS)

    Robinson, Peter J.

    2000-07-01

    In this study, hourly data for the 1951-1990 period for 178 stations in the coterminous United States were used to establish temporal trends in dew point temperature. Although the data had been quality controlled previously (Robinson, 1998. Monthly variations of dew point temperatures in the coterminous United States. International Journal of Climatology 18: 1539-1556), comparisons of values between nearby stations suggested that instrumental changes, combined with locational changes, may have modified the results by as much as 1°C during the 40-year period. Nevertheless, seasonally averaged results indicated an increase over much of the area, of slightly over 1°C/100 years in spring and autumn, slightly less than this in summer. Winter displayed a drying of over 1°C/100 years. When only the 1961-1990 period was considered, the patterns were similar and trends increased by approximately 1-2°C/100 years, except in autumn, which displayed a slight drying. Analyses for specific stations indicated periods of both increasing and decreasing Td, the change between them varying with observation hour. No single change point was common over a wide area, although January commonly indicated maximum values early in the period in the east and west, and much later in the north-central portion. Rates of increase were generally higher in daytime than at night, especially in summer. Investigation of the inter-decadal differences in dew point, as a function of wind conditions, indicated that changes during calm conditions were commonly similar in magnitude to that of the overall average changes, suggesting an important role for the local hydrologic cycle in driving changes. Other inter-decadal changes could be attributed to the changes in the frequency and moisture content of invading air-streams. This was particularly clear for the changes in north-south flow in the interior.

  12. Hourly predictive Levenberg-Marquardt ANN and multi linear regression models for predicting of dew point temperature

    NASA Astrophysics Data System (ADS)

    Zounemat-Kermani, Mohammad

    2012-08-01

    In this study, the ability of two models of multi linear regression (MLR) and Levenberg-Marquardt (LM) feed-forward neural network was examined to estimate the hourly dew point temperature. Dew point temperature is the temperature at which water vapor in the air condenses into liquid. This temperature can be useful in estimating meteorological variables such as fog, rain, snow, dew, and evapotranspiration and in investigating agronomical issues as stomatal closure in plants. The availability of hourly records of climatic data (air temperature, relative humidity and pressure) which could be used to predict dew point temperature initiated the practice of modeling. Additionally, the wind vector (wind speed magnitude and direction) and conceptual input of weather condition were employed as other input variables. The three quantitative standard statistical performance evaluation measures, i.e. the root mean squared error, mean absolute error, and absolute logarithmic Nash-Sutcliffe efficiency coefficient ( {| {{{Log}}({{NS}})} |} ) were employed to evaluate the performances of the developed models. The results showed that applying wind vector and weather condition as input vectors along with meteorological variables could slightly increase the ANN and MLR predictive accuracy. The results also revealed that LM-NN was superior to MLR model and the best performance was obtained by considering all potential input variables in terms of different evaluation criteria.

  13. Investigation of potential factors affecting the measurement of dew point temperature in oil-soaked transformers

    NASA Astrophysics Data System (ADS)

    Kraus, Adam H.

    Moisture within a transformer's insulation system has been proven to degrade its dielectric strength. When installing a transformer in situ, one method used to calculate the moisture content of the transformer insulation is to measure the dew point temperature of the internal gas volume of the transformer tank. There are two instruments commercially available that are designed for dew point temperature measurement: the Alnor Model 7000 Dewpointer and the Vaisala DRYCAPRTM Hand-Held Dewpoint Meter DM70. Although these instruments perform an identical task, the design technology behind each instrument is vastly different. When the Alnor Dewpointer and Vaisala DM70 instruments are used to measure the dew point of the internal gas volume simultaneously from a pressurized transformer, their differences in dew point measurement have been observed to vary as much as 30 °F. There is minimal scientific research available that focuses on the process of measuring dew point of a gas inside a pressurized transformer, let alone this observed phenomenon. The primary objective of this work was to determine what effect certain factors potentially have on dew point measurements of a transformer's internal gas volume, in hopes of understanding the root cause of this phenomenon. Three factors that were studied include (1) human error, (2) the use of calibrated and out-of-calibration instruments, and (3) the presence of oil vapor gases in the dry air sample, and their subsequent effects on the Q-value of the sampled gas. After completing this portion of testing, none of the selected variables proved to be a direct cause of the observed discrepancies between the two instruments. The secondary objective was to validate the accuracy of each instrument as compared to its respective published range by testing against a known dew point temperature produced by a humidity generator. In a select operating range of -22 °F to -4 °F, both instruments were found to be accurate and within their

  14. The effect of water contamination on the dew-point temperature scale realization with humidity generators

    NASA Astrophysics Data System (ADS)

    Vilbaste, M.; Heinonen, M.; Saks, O.; Leito, I.

    2013-08-01

    The purpose of this paper is to study the effect of contaminated water in the context of humidity generators. Investigation of different methods to determine the drop in dew-point temperature due to contamination and experiments on actual contamination rates are reported. Different methods for calculating the dew-point temperature effect from electrical conductivity and density measurements are studied with high-purity water and aqueous solutions of NaCl and LiCl. The outcomes of the calculation methods are compared with the results of direct humidity measurements. The results show that the often applied Raoult's law based calculation method is in good agreement with other methods. For studying actual contamination, water samples were kept in glass, plastic, copper and stainless-steel vessels for up to 13 months to investigate natural ionic and organic contamination in vessels with different wall materials. The amount of ionic contamination was found to be higher in copper and glass vessels than in stainless-steel and plastic vessels. The amount of organic contamination was found to be highest in the plastic vessel. In all the cases, however, the corresponding drop in dew-point temperature due to natural contamination was found to be below 0.1 mK. The largest rate of change of dew-point temperature was 26 µK/month. Thus, if proper cleanness is maintained in a humidity generator the effect of contamination of water in the saturator is insignificant compared with the major uncertainty components even in the most accurate generators today.

  15. Laser Dew-Point Hygrometer

    NASA Astrophysics Data System (ADS)

    Matsumoto, Shigeaki; Toyooka, Satoru

    1995-01-01

    A rough-surface-type automatic dew-point hygrometer was developed using a laser diode and an optical fiber cable. A gold plate with 0.8 µ m average surface roughness was used as a surface for deposition of dew to facilitate dew deposition and prevent supersaturation of water vapor at the dew point. It was shown experimentally that the quantity of dew deposited can be controlled to be constant at any predetermined level, and is independent of the dew point to be measured. The dew points were measured in the range from -15° C to 54° C in which the temperature ranged from 0° C to 60° C. The measurement error of the dew point was ±0.5° C which was equal to below ±2% in relative humidity in the above dew-point range.

  16. Development of the High-Temperature Dew-Point Generator Over the Past 15 Years

    NASA Astrophysics Data System (ADS)

    Bosma, R.; Nielsen, J.; Peruzzi, A.

    2017-10-01

    At VSL a humidity generator was designed and constructed in the early 1990s. This generator was of the re-circulating-single-pressure type. Over the years, the generator has been thoroughly revised and several critical components have been replaced. Among others the pre-saturator and the change from re-circulation to single-pass mode. Validating experiments showed that the range of the new setup could be extended from 70 {°}C to 95 {°}C dew-point temperature, and the last modification allows an uncertainty of 0.048 {°}C (k = 2) at the maximum temperature. In 2009 the setup was used in the Euramet-T-K8 humidity intercomparison at temperatures up to 95 {°}C. In the period from 2003 to 2015, four state-of-the-art chilled mirror hygrometers were regularly calibrated with the generator. One of these was also calibrated with the primary dew-point standards of several other European National Metrology Institutes, which made it possible to link the VSL generator to the generators used in these institutes. An analysis of the results of these calibrations shows an agreement in calibration capabilities within 0.01 {°}C with PTB and NPL.

  17. Experiment Comparison between Engineering Acid Dew Point and Thermodynamic Acid Dew Point

    NASA Astrophysics Data System (ADS)

    Song, Jinghui; Yuan, Hui; Deng, Jianhua

    2018-06-01

    in order to realize the accurate prediction of acid dew point, a set of measurement system of acid dew point for the flue gas flue gas in the tail of the boiler was designed and built, And measured at the outlet of an air preheater of a power plant of 1 000 MW, The results show that: Under the same conditions, with the test temperature decreases, Nu of heat transfer tubes, fouling and corrosion of pipe wall and corrosion pieces gradually deepened. Then, the measured acid dew point is compared with the acid dew point obtained by using the existing empirical formula under the same coal type. The dew point of engineering acid is usually about 40 ° lower than the dew point of thermodynamic acid because of the coupling effect of fouling on the acid liquid, which can better reflect the actual operation of flue gas in engineering and has certain theoretical guidance for the design and operation of deep waste heat utilization system significance.

  18. Future PMPs Estimation in Korea under AR5 RCP 8.5 Climate Change Scenario: Focus on Dew Point Temperature Change

    NASA Astrophysics Data System (ADS)

    Okjeong, Lee; Sangdan, Kim

    2016-04-01

    According to future climate change scenarios, future temperature is expected to increase gradually. Therefore, it is necessary to reflect the effects of these climate changes to predict Probable Maximum Precipitations (PMPs). In this presentation, PMPs will be estimated with future dew point temperature change. After selecting 174 major storm events from 1981 to 2005, new PMPs will be proposed with respect to storm areas (25, 100, 225, 400, 900, 2,025, 4,900, 10,000 and 19,600 km2) and storm durations (1, 2, 4, 6, 8, 12, 18, 24, 48 and 72 hours) using the Korea hydro-meteorological method. Also, orographic transposition factor will be applied in place of the conventional terrain impact factor which has been used in previous Korean PMPs estimation reports. After estimating dew point temperature using future temperature and representative humidity information under the Korea Meteorological Administration AR5 RCP 8.5, changes in the PMPs under dew point temperature change will be investigated by comparison with present and future PMPs. This research was supported by a grant(14AWMP-B082564-01) from Advanced Water Management Research Program funded by Ministry of Land, Infrastructure and Transport of Korean government.

  19. Measurement Uncertainty of Dew-Point Temperature in a Two-Pressure Humidity Generator

    NASA Astrophysics Data System (ADS)

    Martins, L. Lages; Ribeiro, A. Silva; Alves e Sousa, J.; Forbes, Alistair B.

    2012-09-01

    This article describes the measurement uncertainty evaluation of the dew-point temperature when using a two-pressure humidity generator as a reference standard. The estimation of the dew-point temperature involves the solution of a non-linear equation for which iterative solution techniques, such as the Newton-Raphson method, are required. Previous studies have already been carried out using the GUM method and the Monte Carlo method but have not discussed the impact of the approximate numerical method used to provide the temperature estimation. One of the aims of this article is to take this approximation into account. Following the guidelines presented in the GUM Supplement 1, two alternative approaches can be developed: the forward measurement uncertainty propagation by the Monte Carlo method when using the Newton-Raphson numerical procedure; and the inverse measurement uncertainty propagation by Bayesian inference, based on prior available information regarding the usual dispersion of values obtained by the calibration process. The measurement uncertainties obtained using these two methods can be compared with previous results. Other relevant issues concerning this research are the broad application to measurements that require hygrometric conditions obtained from two-pressure humidity generators and, also, the ability to provide a solution that can be applied to similar iterative models. The research also studied the factors influencing both the use of the Monte Carlo method (such as the seed value and the convergence parameter) and the inverse uncertainty propagation using Bayesian inference (such as the pre-assigned tolerance, prior estimate, and standard deviation) in terms of their accuracy and adequacy.

  20. Monthly variations of dew point temperature in the coterminous United States

    NASA Astrophysics Data System (ADS)

    Robinson, Peter J.

    1998-11-01

    The dew point temperature, Td, data from the surface airways data set of the U.S. National Climatic Data Center were used to develop a basic dew point climatology for the coterminous United States. Quality control procedures were an integral part of the analysis. Daily Td, derived as the average of eight observations at 3-hourly intervals, for 222 stations for the 1961-1990 period were used. The annual and seasonal pattern of average values showed a clear south-north decrease in the eastern portion of the nation, a trend which was most marked in winter. In the west, values decreased inland from the Pacific Coast. Inter-annual variability was generally low when actual mean values were high. A cluster analysis suggested that the area could be divided into six regions, two oriented north-south in the west, four aligned east-west in the area east of the Rocky Mountains. Day-to-day variability was low in all seasons in the two western clusters, but showed a distinct winter maximum in the east. This was explained in broad terms by consideration of air flow regimes, with the Pacific Ocean and the Gulf of Mexico acting as the major moisture sources. Comparison of values for pairs of nearby stations suggested that Td was rather insensitive to local moisture sources. Analysis of the patterns of occurrence of dew points exceeding the 95th percentile threshold indicated that extremes in summer tend to be localized and short-lived, while in winter they are more widespread and persistent.

  1. A micro dew point sensor with a thermal detection principle

    NASA Astrophysics Data System (ADS)

    Kunze, M.; Merz, J.; Hummel, W.-J.; Glosch, H.; Messner, S.; Zengerle, R.

    2012-01-01

    We present a dew point temperature sensor with the thermal detection of condensed water on a thin membrane, fabricated by silicon micromachining. The membrane (600 × 600 × ~1 µm3) is part of a silicon chip and contains a heating element as well as a thermopile for temperature measurement. By dynamically heating the membrane and simultaneously analyzing the transient increase of its temperature it is detected whether condensed water is on the membrane or not. To cool the membrane down, a peltier cooler is used and electronically controlled in a way that the temperature of the membrane is constantly held at a value where condensation of water begins. This temperature is measured and output as dew point temperature. The sensor system works in a wide range of dew point temperatures between 1 K and down to 44 K below air temperature. In experimental investigations it could be proven that the deviation of the measured dew point temperatures compared to reference values is below ±0.2 K in an air temperature range of 22 to 70 °C. At low dew point temperatures of -20 °C (air temperature = 22 °C) the deviation increases to nearly -1 K.

  2. A New Primary Dew-Point Generator at TUBITAK UME

    NASA Astrophysics Data System (ADS)

    Oğuz Aytekin, S.; Karaböce, N.; Heinonen, M.; Sairanen, H.

    2018-05-01

    An implementation of a new low-range primary humidity generator as a part of an international collaboration between TUBITAK UME and VTT MIKES was initiated as a EURAMET Project Number 1259. The dew-point generator was designed and constructed within the scope of the cooperation between TUBITAK UME and VTT MIKES in order to extend the dew-point temperature measurement capability of Humidity Laboratory of TUBITAK UME down to - 80 °C. The system was thoroughly characterized and validated at TUBITAK UME to support the evidence for dew-point temperature uncertainties. The new generator has a capability of operating in the range of - 80 °C to +10 °C, but at the moment, it was characterized down to - 60 °C. The core of the generator system is a saturator which is fully immersed in a liquid bath. Dry air is supplied to the saturator through a temperature-controlled pre-saturator. The operation of the system is based on the single-pressure generation method with a single pass, i.e., the dew-point temperature is only controlled by the saturator temperature, and the humidity-controlled air is not returned to the system after leaving of the saturator. The metrological performance of the saturator was investigated thoroughly at both National Metrology Institutes. The pre-saturator was also tested using a thermostatic bath at VTT MIKES prior to sending them to TUBITAK UME. This paper describes the principle and design of the generator in detail. The dew-point measurement system and the corresponding uncertainty analysis of the dew-point temperature scale realized with the generator in the range from - 60 °C to 10 °C is also presented.

  3. Observed changes in relative humidity and dew point temperature in coastal regions of Iran

    NASA Astrophysics Data System (ADS)

    Hosseinzadeh Talaee, P.; Sabziparvar, A. A.; Tabari, Hossein

    2012-12-01

    The analysis of trends in hydroclimatic parameters and assessment of their statistical significance have recently received a great concern to clarify whether or not there is an obvious climate change. In the current study, parametric linear regression and nonparametric Mann-Kendall tests were applied for detecting annual and seasonal trends in the relative humidity (RH) and dew point temperature ( T dew) time series at ten coastal weather stations in Iran during 1966-2005. The serial structure of the data was considered, and the significant serial correlations were eliminated using the trend-free pre-whitening method. The results showed that annual RH increased by 1.03 and 0.28 %/decade at the northern and southern coastal regions of the country, respectively, while annual T dew increased by 0.29 and 0.15°C per decade at the northern and southern regions, respectively. The significant trends were frequent in the T dew series, but they were observed only at 2 out of the 50 RH series. The results showed that the difference between the results of the parametric and nonparametric tests was small, although the parametric test detected larger significant trends in the RH and T dew time series. Furthermore, the differences between the results of the trend tests were not related to the normality of the statistical distribution.

  4. Dew-point measurements at high water vapour pressure

    NASA Astrophysics Data System (ADS)

    Lomperski, S.; Dreier, J.

    1996-05-01

    A dew-point meter capable of measuring humidity at high vapour pressure and high temperature has been constructed and tested. Humidity measurements in pure steam were made over the temperature range 100 - 1500957-0233/7/5/003/img1C and a vapour pressure range of 1 - 4 bar. The dew-point meter performance was assessed by comparing measurements with a pressure transmitter and agreement between the two was within 0957-0233/7/5/003/img2% relative humidity. Humidity measurements in steam - air mixtures were also made and the dew-point meter readings were compared to those of a zirconia oxygen sensor. For these tests the dew-point meter readings were generally within 0957-0233/7/5/003/img2% relative humidity of the oxygen sensor measurements.

  5. SHORT COMMUNICATION: Recognition of supercooled dew in a quartz crystal microbalance dew-point sensor by slip phenomena

    NASA Astrophysics Data System (ADS)

    Kwon, Su-Yong; Kim, Jong-Chul; Choi, Byung-Il

    2007-10-01

    Distinguishing between a supercooled dew and frost below 0 °C in dew/frost-point measurements is an important and challenging problem that has not yet been completely solved. This study presents a new method for the recognition of a supercooled dew in a dew/frost-point sensor. A quartz crystal microbalance (QCM) sensor was used as a dew/frost-point sensor to detect a dew and a supercooled dew as well as frost. The slip phenomenon occurring at an interface between the water droplet and the surface of the quartz crystal resonator of the QCM sensor gives a simple and accurate way of distinguishing between a supercooled dew and frost below 0 °C. This method can give a highly accurate measurement of the dew or the frost point without misreading in the dew-point sensor at temperatures below 0 °C.

  6. Integrated CMOS dew point sensors for relative humidity measurement

    NASA Astrophysics Data System (ADS)

    Savalli, Nicolo; Baglio, Salvatore; Castorina, Salvatore; Sacco, Vincenzo; Tringali, Cristina

    2004-07-01

    This work deals with the development of integrated relative humidity dew point sensors realized by adopting standard CMOS technology for applications in various fields. The proposed system is composed by a suspended plate that is cooled by exploiting integrated Peltier cells. The cold junctions of the cells have been spread over the plate surface to improve the homogeneity of the temperature distribution over its surface, where cooling will cause the water condensation. The temperature at which water drops occur, named dew point temperature, is a function of the air humidity. Measurement of such dew point temperature and the ambient temperature allows to know the relative humidity. The detection of water drops is achieved by adopting a capacitive sensing strategy realized by interdigited fixed combs, composed by the upper layer of the adopted process. Such a capacitive sensor, together with its conditioning circuit, drives a trigger that stops the cooling of the plate and enables the reading of the dew point temperature. Temperature measurements are achieved by means of suitably integrated thermocouples. The analytical model of the proposed system has been developed and has been used to design a prototype device and to estimate its performances. In such a prototype, the thermoelectric cooler is composed by 56 Peltier cells, made by metal 1/poly 1 junctions. The plate has a square shape with 200 μm side, and it is realized by exploiting the oxide layers. Starting from the ambient temperature a temperature variation of ΔT = 15 K can be reached in 10 ms thus allowing to measure a relative humidity greater than 40%.

  7. Wet-bulb, dew point, and air temperature trends in Spain

    NASA Astrophysics Data System (ADS)

    Moratiel, R.; Soriano, B.; Centeno, A.; Spano, D.; Snyder, R. L.

    2017-10-01

    This study analyses trends of mean ( T m), maximum ( T x), minimum ( T n), dew point ( T d), and wet-bulb temperatures ( T w) on an annual, seasonal, and monthly time scale over Spain during the period 1981-2010. The main purpose was to determine how temperature and humidity changes are impacting on T w, which is probably a better measure of climate change than temperature alone. In this study, 43 weather stations were used to detect data trends using the nonparametric Mann-Kendall test and the Sen method to estimate the slope of trends. Significant linear trends observed for T m, T x, and T n versus year were 56, 58, and 47 % of the weather stations, respectively, with temperature ranges between 0.2 and 0.4 °C per decade. The months with bigger trends were April, May, June, and July with the highest trend for T x. The spatial behaviour of T d and T w was variable, with various locations showing trends from -0.6 to +0.3 °C per decade for T d and from -0.4 to +0.5 °C per decade for T w. Both T d and T w showed negative trends for July, August, September, November, and December. Comparing the trends versus time of each variable versus each of the other variables exhibited poor relationships, which means you cannot predict the trend of one variable from the trend of another variable. The trend of T x was not related to the trend of T n. The trends of T x, T m, and T n versus time were unrelated to the trends versus time of either T d or T w. The trend of T w showed a high coefficient of determination with the trend of T d with an annual value of R 2 = 0.86. Therefore, the T w trend is more related to changes in humidity than temperature.

  8. A microwave resonance dew-point hygrometer

    NASA Astrophysics Data System (ADS)

    Underwood, R. J.; Cuccaro, R.; Bell, S.; Gavioso, R. M.; Madonna Ripa, D.; Stevens, M.; de Podesta, M.

    2012-08-01

    We report the first measurements of a quasi-spherical microwave resonator used as a dew-point hygrometer. In conventional dew-point hygrometers, the condensation of water from humid gas flowing over a mirror is detected optically, and the mirror surface is then temperature-controlled to yield a stable condensed layer. In our experiments we flowed moist air from a humidity generator through a quasi-spherical resonator and detected the onset of condensation by measuring the frequency ratio of selected microwave modes. We verified the basic operation of the device over the dew-point range 9.5-13.5 °C by comparison with calibrated chilled-mirror hygrometers. These tests indicate that the microwave method may allow a quantitative estimation of the volume and thickness of the water layer which is condensed on the inner surface of the resonator. The experiments reported here are preliminary due to the limited time available for the work, but show the potential of the method for detecting not only water but a variety of other liquid or solid condensates. The robust all-metal construction should make the device appropriate for use in industrial applications over a wide range of temperatures and pressures.

  9. Consistency of the National Realization of Dew-Point Temperature Using Standard Humidity Generators

    NASA Astrophysics Data System (ADS)

    Benyon, R.; Vicente, T.

    2012-09-01

    The comparison of two high-range standard humidity generators used by Instituto Nacional de Técnica Aeroespacial to realize dew-point temperature in the range from -10 °C to +95 °C has been performed using state-of-the art transfer standards and measurement procedures, over their overlapping range from -10 °C to +75 °C. The aim of this study is to investigate the level of agreement between the two generators, to determine any bias, and to quantify the level of consistency of the two realizations. The measurement procedures adopted to minimize the effect of the influence factors due to the transfer standards are described, and the results are discussed in the context of the declared calibration and measurement capabilities (CMCs).

  10. A new comparison method for dew-point generators

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    1999-12-01

    A new method for comparing dew-point generators was developed at the Centre for Metrology and Accreditation. In this method, the generators participating in a comparison are compared with a transportable saturator unit using a dew-point comparator. The method was tested by constructing a test apparatus and by comparing it with the MIKES primary dew-point generator several times in the dew-point temperature range from -40 to +75 °C. The expanded uncertainty (k = 2) of the apparatus was estimated to be between 0.05 and 0.07 °C and the difference between the comparator system and the generator is well within these limits. In particular, all of the results obtained in the range below 0 °C are within ±0.03 °C. It is concluded that a new type of a transfer standard with characteristics most suitable for dew-point comparisons can be developed on the basis of the principles presented in this paper.

  11. Estimation of Initial and Response Times of Laser Dew-Point Hygrometer by Measurement Simulation

    NASA Astrophysics Data System (ADS)

    Matsumoto, Sigeaki; Toyooka, Satoru

    1995-10-01

    The initial and the response times of the laser dew-point hygrometer were evaluated by measurement simulation. The simulation was based on loop computations of the surface temperature of a plate with dew deposition, the quantity of dew deposited and the intensity of scattered light from the surface at each short interval of measurement. The initial time was defined as the time necessary for the hygrometer to reach a temperature within ±0.5° C of the measured dew point from the start time of measurement, and the response time was also defined for stepwise dew-point changes of +5° C and -5° C. The simulation results are in approximate agreement with the recorded temperature and intensity of scattered light of the hygrometer. The evaluated initial time ranged from 0.3 min to 5 min in the temperature range from 0° C to 60° C, and the response time was also evaluated to be from 0.2 min to 3 min.

  12. Vertical profiles of ozone, carbon monoxide, and dew-point temperature obtained during GTE/CITE 1, October-November 1983. [Chemical Instrumentation Test and Evaluation

    NASA Technical Reports Server (NTRS)

    Fishman, Jack; Gregory, Gerald L.; Sachse, Glen W.; Beck, Sherwin M.; Hill, Gerald F.

    1987-01-01

    A set of 14 pairs of vertical profiles of ozone and carbon monoxide, obtained with fast-response instrumentation, is presented. Most of these profiles, which were measured in the remote troposphere, also have supporting fast-response dew-point temperature profiles. The data suggest that the continental boundary layer is a source of tropospheric ozone, even in October and November, when photochemical activity should be rather small. In general, the small-scale vertical variability between CO and O3 is in phase. At low latitudes this relationship defines levels in the atmosphere where midlatitude air is being transported to lower latitudes, since lower dew-point temperatures accompany these higher CO and O3 concentrations. A set of profiles which is suggestive of interhemispheric transport is also presented. Independent meteorological analyses support these interpretations.

  13. Investigation of the Equivalence of National Dew-Point Temperature Realizations in the -50 °C to + 20 °C Range

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti; Anagnostou, Miltiadis; Bell, Stephanie; Stevens, Mark; Benyon, Robert; Bergerud, Reidun Anita; Bojkovski, Jovan; Bosma, Rien; Nielsen, Jan; Böse, Norbert; Cromwell, Plunkett; Kartal Dogan, Aliye; Aytekin, Seda; Uytun, Ali; Fernicola, Vito; Flakiewicz, Krzysztof; Blanquart, Bertrand; Hudoklin, Domen; Jacobson, Per; Kentved, Anders; Lóio, Isabel; Mamontov, George; Masarykova, Alexandra; Mitter, Helmut; Mnguni, Regina; Otych, Jan; Steiner, Anton; Szilágyi Zsófia, Nagyné; Zvizdic, Davor

    2012-09-01

    In the field of humidity quantities, the first CIPM key comparison, CCT-K6 is at its end. The corresponding European regional key comparison, EUROMET.T-K6, was completed in early 2008, about 4 years after the starting initial measurements in the project. In total, 24 NMIs from different countries took part in the comparison. This number includes 22 EURAMET countries, and Russia and South Africa. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was carried out in three parallel loops, each with two chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. It is shown that the standard uncertainty due to the long-term instability was smaller than 0.008 °C in all loops. The standard uncertainties due to links between the loops were found to be smaller than 0.025 °C at -50 °C and 0.010 °C elsewhere. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from the EURAMET comparison reference values (ERV). Taking into account 16 different primary dew-point realizations and 8 secondary realizations, the results demonstrate the equivalence of a large number of laboratories at an uncertainty level that is better than achieved in other multilateral comparisons so far in the humidity field.

  14. Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method.

    PubMed

    Lin, Ningning; Meng, Xiaofeng; Nie, Jing

    2016-11-18

    In this paper, the influence of temperature on quartz crystal microbalance (QCM) sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of -3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability.

  15. An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform.

    PubMed

    Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong

    2016-07-15

    The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard "chilled-mirror" dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional "chilled-mirror" hygrometers. Moreover, this DPS outperforms conventional "chilled-mirror" hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.

  16. A quartz crystal microbalance dew point sensor without frequency measurement

    NASA Astrophysics Data System (ADS)

    Wang, Guohua; Zhang, Weishuo; Wang, Shuo; Sun, Jinglin

    2014-11-01

    This work deals with the design of a dew point sensor based on Quartz Crystal Microbalance (QCM) without measuring the frequency. This idea is inspired by the fact that the Colpitts oscillation circuit will stop oscillating when the QCM works in the liquid media. The quartz crystal and the electrode are designed through the finite element simulation and the stop oscillating experiment is conducted to verify the sensibility. Moreover, the measurement result is calibrated to approach the true value. At last a series of dew points at the same temperature is measured with the designed sensor. Results show that the designed dew point sensor is able to detect the dew point with the proper accuracy.

  17. A Quartz Crystal Microbalance dew point sensor without frequency measurement.

    PubMed

    Wang, Guohua; Zhang, Weishuo; Wang, Shuo; Sun, Jinglin

    2014-11-01

    This work deals with the design of a dew point sensor based on Quartz Crystal Microbalance (QCM) without measuring the frequency. This idea is inspired by the fact that the Colpitts oscillation circuit will stop oscillating when the QCM works in the liquid media. The quartz crystal and the electrode are designed through the finite element simulation and the stop oscillating experiment is conducted to verify the sensibility. Moreover, the measurement result is calibrated to approach the true value. At last a series of dew points at the same temperature is measured with the designed sensor. Results show that the designed dew point sensor is able to detect the dew point with the proper accuracy.

  18. Intercomparison of the Dew-Point Temperature Realizations at LPM and MIKES in the Range from -70 °C to + 20 ° C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2012-09-01

    The first European humidity key comparison EURAMET-T.K6 was completed in 2008, and it covered the dew-point temperature range from -50 °C to + 20 °C. Both LPM and MIKES participated in the comparison, but a new low dew-point generator was introduced at LPM as a result of progress in the EUROMET P912 project. To extend the range of available comparison evidence down to -70 °C and to study the validity of improved uncertainties of LPM, a bilateral comparison was carried out between LPM and MIKES in 2009-2010. The applied comparison procedure was similar to that applied in EURAMET-T.K6. However, only one transfer standard was used instead of two units and the measurement point -70 °C was added in the measurement scheme. The results show that the bilateral equivalence between LPM and MIKES is between (0.00 ± 0.06) °C and (0.02 ± 0.08) °C in the range from -50 °C to + 20 °C and (0.01 ± 0.10) °C at -70 °C. Using MIKES results as the link to the EURAMET.T-K6, it is shown that the difference between the results obtained with the new LPM dew-point temperature standard and the EURAMET Comparison Reference Values is between (-0.02 ± 0.08) °C at 20 °C and (+ 0.02 ± 0.07) ° C at -50 °C.

  19. Dew Point Calibration System Using a Quartz Crystal Sensor with a Differential Frequency Method

    PubMed Central

    Lin, Ningning; Meng, Xiaofeng; Nie, Jing

    2016-01-01

    In this paper, the influence of temperature on quartz crystal microbalance (QCM) sensor response during dew point calibration is investigated. The aim is to present a compensation method to eliminate temperature impact on frequency acquisition. A new sensitive structure is proposed with double QCMs. One is kept in contact with the environment, whereas the other is not exposed to the atmosphere. There is a thermal conductivity silicone pad between each crystal and a refrigeration device to keep a uniform temperature condition. A differential frequency method is described in detail and is applied to calibrate the frequency characteristics of QCM at the dew point of −3.75 °C. It is worth noting that frequency changes of two QCMs were approximately opposite when temperature conditions were changed simultaneously. The results from continuous experiments show that the frequencies of two QCMs as the dew point moment was reached have strong consistency and high repeatability, leading to the conclusion that the sensitive structure can calibrate dew points with high reliability. PMID:27869746

  20. Note: A dual-channel sensor for dew point measurement based on quartz crystal microbalance

    NASA Astrophysics Data System (ADS)

    Li, Ning; Meng, Xiaofeng; Nie, Jing

    2017-05-01

    A new sensor with dual-channel was designed for eliminating the temperature effect on the frequency measurement of the quartz crystal microbalance (QCM) in dew point detection. The sensor uses active temperature control, produces condensation on the surface of QCM, and then detects the dew point. Both the single-channel and the dual-channel methods were conducted based on the device. The measurement error of the single-channel method was less than 0.5 °C at the dew point range of -2 °C-10 °C while the dual-channel was 0.3 °C. The results showed that the dual-channel method was able to eliminate the temperature effect and yield better measurement accuracy.

  1. Note: A dual-channel sensor for dew point measurement based on quartz crystal microbalance.

    PubMed

    Li, Ning; Meng, Xiaofeng; Nie, Jing

    2017-05-01

    A new sensor with dual-channel was designed for eliminating the temperature effect on the frequency measurement of the quartz crystal microbalance (QCM) in dew point detection. The sensor uses active temperature control, produces condensation on the surface of QCM, and then detects the dew point. Both the single-channel and the dual-channel methods were conducted based on the device. The measurement error of the single-channel method was less than 0.5 °C at the dew point range of -2 °C-10 °C while the dual-channel was 0.3 °C. The results showed that the dual-channel method was able to eliminate the temperature effect and yield better measurement accuracy.

  2. An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform

    NASA Astrophysics Data System (ADS)

    Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong

    2016-07-01

    The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints.

  3. An ultrahigh-accuracy Miniature Dew Point Sensor based on an Integrated Photonics Platform

    PubMed Central

    Tao, Jifang; Luo, Yu; Wang, Li; Cai, Hong; Sun, Tao; Song, Junfeng; Liu, Hui; Gu, Yuandong

    2016-01-01

    The dew point is the temperature at which vapour begins to condense out of the gaseous phase. The deterministic relationship between the dew point and humidity is the basis for the industry-standard “chilled-mirror” dew point hygrometers used for highly accurate humidity measurements, which are essential for a broad range of industrial and metrological applications. However, these instruments have several limitations, such as high cost, large size and slow response. In this report, we demonstrate a compact, integrated photonic dew point sensor (DPS) that features high accuracy, a small footprint, and fast response. The fundamental component of this DPS is a partially exposed photonic micro-ring resonator, which serves two functions simultaneously: 1) sensing the condensed water droplets via evanescent fields and 2) functioning as a highly accurate, in situ temperature sensor based on the thermo-optic effect (TOE). This device virtually eliminates most of the temperature-related errors that affect conventional “chilled-mirror” hygrometers. Moreover, this DPS outperforms conventional “chilled-mirror” hygrometers with respect to size, cost and response time, paving the way for on-chip dew point detection and extension to applications for which the conventional technology is unsuitable because of size, cost, and other constraints. PMID:27417734

  4. Development of measurement simulation of the laser dew-point hygrometer using an optical fiber cable

    NASA Astrophysics Data System (ADS)

    Matsumoto, Shigeaki

    2005-02-01

    In order to improve the initial and the response times of the Laser Dew-Point Hygrometer (LDH), the measurement simulation was developed on the basis of the loop computation of the surface temperature of a gold plate for dew depostition, the quantity of deposited dew and the intensity of scattered light from the surface of the plate at time interval of 5 sec during measurement. A more detailed relationship between the surface temperature of the plate and the cooling current, and the time constant of the integrator in the control circuit of the LDH were introduced in the simulation program as a function of atmospheric temperature. The simulation was more close to the actual measurement by the LDH. The simulation results indicated the possibility of improving both the times of teh LDH by the increase of the sensitivity of dew and that of the mass transfer coefficient of dew deposited on the plate surface. It was concluded that the initial and the response times could be improved to below 100sec and 120 sec, respectively in the dew-point range at room temperature, that are almost half of the those times of the original LDH.

  5. Trends in extremes of temperature, dew point, and precipitation from long instrumental series from central Europe

    NASA Astrophysics Data System (ADS)

    Kürbis, K.; Mudelsee, M.; Tetzlaff, G.; Brázdil, R.

    2009-09-01

    For the analysis of trends in weather extremes, we introduce a diagnostic index variable, the exceedance product, which combines intensity and frequency of extremes. We separate trends in higher moments from trends in mean or standard deviation and use bootstrap resampling to evaluate statistical significances. The application of the concept of the exceedance product to daily meteorological time series from Potsdam (1893 to 2005) and Prague-Klementinum (1775 to 2004) reveals that extremely cold winters occurred only until the mid-20th century, whereas warm winters show upward trends. These changes were significant in higher moments of the temperature distribution. In contrast, trends in summer temperature extremes (e.g., the 2003 European heatwave) can be explained by linear changes in mean or standard deviation. While precipitation at Potsdam does not show pronounced trends, dew point does exhibit a change from maximum extremes during the 1960s to minimum extremes during the 1970s.

  6. Experimental study of influence characteristics of flue gas fly ash on acid dew point

    NASA Astrophysics Data System (ADS)

    Song, Jinhui; Li, Jiahu; Wang, Shuai; Yuan, Hui; Ren, Zhongqiang

    2017-12-01

    The long-term operation experience of a large number of utility boilers shows that the measured value of acid dew point is generally lower than estimated value. This is because the influence of CaO and MgO on acid dew point in flue gas fly ash is not considered in the estimation formula of acid dew point. On the basis of previous studies, the experimental device for acid dew point measurement was designed and constructed, and the acid dew point under different smoke conditions was measured. The results show that the CaO and MgO in the flue gas fly ash have an obvious influence on the acid dew point, and the content of the fly ash is negatively correlated with the temperature of acid dew point At the same time, the concentration of H2SO4 in flue gas is different, and the acid dew point of flue gas is different, and positively correlated with the acid dew point.

  7. Study of temperature, air dew point temperature and reactant flow effects on proton exchange membrane fuel cell performances using electrochemical spectroscopy and voltammetry techniques

    NASA Astrophysics Data System (ADS)

    Wasterlain, S.; Candusso, D.; Hissel, D.; Harel, F.; Bergman, P.; Menard, P.; Anwar, M.

    A single PEMFC has been operated by varying the assembly temperature, the air dew point temperature and the anode/cathode stoichiometry rates with the aim to identify the parameters and combinations of factors affecting the cell performance. Some of the experiments were conducted with low humidified reactants (relative humidity of 12%). The FC characterizations tests have been conducted using in situ electrochemical methods based on load current and cell voltage signal analysis, namely: polarization curves, EIS measurements, cyclic and linear sweep voltammetries (CV and LSV). The impacts of the parameters on the global FC performances were observed using the polarization curves whereas EIS, CV and LSV test results were used to discriminate the different voltage loss sources. The test results suggest that some parameter sets allow maximal output voltages but can also induce material degradation. For instance, higher FC temperature and air flow values can induce significant electrical efficiency benefits, notably by increasing the reversible potential and the reaction kinetics. However, raising the cell temperature can also gradually dry the FC and increase the risk of membrane failure. LSV has also shown that elevated FC temperature and relative humidity can also accelerate the electrolyte degradation (i.e. slightly higher fuel crossover rate) and reduce the lifetime consequently.

  8. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -25 °C TO +20 °C.

    PubMed

    Meyer, C W; Hill, K D

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC.

  9. Effect of the temperature and dew point of the decarburization process on the oxide subscale of a 3% silicon steel

    NASA Astrophysics Data System (ADS)

    Cesar, Maria das Graças M. M.; Mantel, Marc J.

    2003-01-01

    The oxide subscale formed on the decarburization annealing of 3% Si-Fe was investigated using microscopy and spectroscopy techniques. It was found that the morphology as well as the molecular structure of the subscale are affected by temperature and dew point. The results suggest that there is an optimum level of internal oxidation and an optimum fayalite/silica ratio in the subscale to achieve a oriented grain silicon steel having a continuous and smooth ceramic film and low core loss.

  10. BILATERAL KEY COMPARISON SIM.T-K6.1 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −25 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Hill, K.D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April, 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. PMID:26663952

  11. Determination of dew point conditions for CO2 with impurities using microfluidics.

    PubMed

    Song, Wen; Fadaei, Hossein; Sinton, David

    2014-03-18

    Impurities can greatly modify the phase behavior of carbon dioxide (CO2), with significant implications on the safety and cost of transport in pipelines. In this paper we demonstrate a microfluidic approach to measure the dew point of such mixtures, specifically the point at which water in supercritical CO2 mixtures condenses to a liquid state. The method enables direct visualization of dew formation (∼ 1-2 μm diameter droplets) at industrially relevant concentrations, pressures, and temperatures. Dew point measurements for the well-studied case of pure CO2-water agreed well with previous theoretical and experimental data over the range of pressure (up to 13.17 MPa), temperature (up to 50 °C), and water content (down to 0.00229 mol fraction) studied. The microfluidic approach showed a nearly 3-fold reduction in error as compared to previous methods. When applied to a mixture with nitrogen (2.5%) and oxygen (5.8%) impurities--typical of flue gas from natural gas oxy-fuel combustion processes--the measured dew point pressure increased on average 17.55 ± 5.4%, indicating a more stringent minimum pressure for pipeline transport. In addition to increased precision, the microfluidic method offers a direct measurement of dew formation, requires very small volumes (∼ 10 μL), and is applicable to ultralow water contents (<0.005 mol fractions), circumventing the limits of previous methods.

  12. [Indoor simulation on dew formation on plant leaves].

    PubMed

    Gao, Zhi-Yong; Wang, You-Ke; Wei, Xin-Guang; Liu, Shou-Yang; He, Zi-Li; Zhou, Yu-Hong

    2014-03-01

    Dew forming on plant leaves through water condensation plays a significant ecological role in arid and semi-arid areas as an ignorable fraction of water resources. In this study, an artificial intelligent climate chamber and an automatic temperature-control system for leaves were implemented to regulate the ambient temperature, the leaf surface temperature and the leaf inclination for dew formation. The impact of leaf inclination, ambient temperature and dew point-leaf temperature depression on the rate and quantity of dew accumulation on leaf surface were analyzed. The results indicated that the accumulation rate and the maximum volume of dew on leaves decreased with increasing the leaf inclination while increased with the increment of dew point-leaf temperature depression, ambient temperature and relative humidity. Under the horizontal configuration, dew accumulated linearly on leaf surface over time until the maximum volume (0.80 mm) was reached. However, dew would fall down after reaching the maximum volume when the leaf inclination existed (45 degrees or 90 degrees), significantly slowing down the accumulative rate, and the zigzag pattern for the dynamic of dew accumulation appeared.

  13. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM -30 °C TO +20 °C.

    PubMed

    Meyer, C W; Solano, A

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range -30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET.

  14. Dew point temperature affects ascospore release of allergenic genus Leptosphaeria

    NASA Astrophysics Data System (ADS)

    Sadyś, Magdalena; Kaczmarek, Joanna; Grinn-Gofron, Agnieszka; Rodinkova, Victoria; Prikhodko, Alex; Bilous, Elena; Strzelczak, Agnieszka; Herbert, Robert J.; Jedryczka, Malgorzata

    2018-06-01

    The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs) and multivariate regression trees (MRTs), we selected the best model for each site, as well as for joint two-site combinations. The performance of all computed models was tested against records from 1 year which had not been used for model construction. The statistical analysis of the fungal spore data was supported by a comprehensive study of both climate and land cover within a 30-km radius from the air sampler location. High-performance forecasting models were obtained for individual sites, showing that the local micro-climate plays a decisive role in biology of the fungi. Based on the previous epidemiological studies, we hypothesized that dew point temperature (DPT) would be a critical factor in the models. The impact of DPT was confirmed only by one of the final best neural models, but the MRT analyses, similarly to the Spearman's rank test, indicated the importance of DPT in all but one of the studied cases and in half of them ranked it as a fundamental factor. This work applies artificial neural modeling to predict the Leptosphaeria airborne spore concentration in urban areas for the first time.

  15. Dew point temperature affects ascospore release of allergenic genus Leptosphaeria

    NASA Astrophysics Data System (ADS)

    Sadyś, Magdalena; Kaczmarek, Joanna; Grinn-Gofron, Agnieszka; Rodinkova, Victoria; Prikhodko, Alex; Bilous, Elena; Strzelczak, Agnieszka; Herbert, Robert J.; Jedryczka, Malgorzata

    2018-01-01

    The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs) and multivariate regression trees (MRTs), we selected the best model for each site, as well as for joint two-site combinations. The performance of all computed models was tested against records from 1 year which had not been used for model construction. The statistical analysis of the fungal spore data was supported by a comprehensive study of both climate and land cover within a 30-km radius from the air sampler location. High-performance forecasting models were obtained for individual sites, showing that the local micro-climate plays a decisive role in biology of the fungi. Based on the previous epidemiological studies, we hypothesized that dew point temperature (DPT) would be a critical factor in the models. The impact of DPT was confirmed only by one of the final best neural models, but the MRT analyses, similarly to the Spearman's rank test, indicated the importance of DPT in all but one of the studied cases and in half of them ranked it as a fundamental factor. This work applies artificial neural modeling to predict the Leptosphaeria airborne spore concentration in urban areas for the first time.

  16. Dew point temperature affects ascospore release of allergenic genus Leptosphaeria.

    PubMed

    Sadyś, Magdalena; Kaczmarek, Joanna; Grinn-Gofron, Agnieszka; Rodinkova, Victoria; Prikhodko, Alex; Bilous, Elena; Strzelczak, Agnieszka; Herbert, Robert J; Jedryczka, Malgorzata

    2018-06-01

    The genus Leptosphaeria contains numerous fungi that cause the symptoms of asthma and also parasitize wild and crop plants. In search of a robust and universal forecast model, the ascospore concentration in air was measured and weather data recorded from 1 March to 31 October between 2006 and 2012. The experiment was conducted in three European countries of the temperate climate, i.e., Ukraine, Poland, and the UK. Out of over 150 forecast models produced using artificial neural networks (ANNs) and multivariate regression trees (MRTs), we selected the best model for each site, as well as for joint two-site combinations. The performance of all computed models was tested against records from 1 year which had not been used for model construction. The statistical analysis of the fungal spore data was supported by a comprehensive study of both climate and land cover within a 30-km radius from the air sampler location. High-performance forecasting models were obtained for individual sites, showing that the local micro-climate plays a decisive role in biology of the fungi. Based on the previous epidemiological studies, we hypothesized that dew point temperature (DPT) would be a critical factor in the models. The impact of DPT was confirmed only by one of the final best neural models, but the MRT analyses, similarly to the Spearman's rank test, indicated the importance of DPT in all but one of the studied cases and in half of them ranked it as a fundamental factor. This work applies artificial neural modeling to predict the Leptosphaeria airborne spore concentration in urban areas for the first time.

  17. A novel method of measuring the concentration of anaesthetic vapours using a dew-point hygrometer.

    PubMed

    Wilkes, A R; Mapleson, W W; Mecklenburgh, J S

    1994-02-01

    The Antoine equation relates the saturated vapour pressure of a volatile substance, such as an anaesthetic agent, to the temperature. The measurement of the 'dew-point' of a dry gas mixture containing a volatile anaesthetic agent by a dew-point hygrometer permits the determination of the partial pressure of the anaesthetic agent. The accuracy of this technique is limited only by the accuracy of the Antoine coefficients and of the temperature measurement. Comparing measurements by the dew-point method with measurements by refractometry showed systematic discrepancies up to 0.2% and random discrepancies with SDS up to 0.07% concentration in the 1% to 5% range for three volatile anaesthetics. The systematic discrepancies may be due to errors in available data for the vapour pressures and/or the refractive indices of the anaesthetics.

  18. Remotely-sensed, nocturnal, dew point correlates with malaria transmission in Southern Province, Zambia: a time-series study.

    PubMed

    Nygren, David; Stoyanov, Cristina; Lewold, Clemens; Månsson, Fredrik; Miller, John; Kamanga, Aniset; Shiff, Clive J

    2014-06-13

    Plasmodium falciparum transmission has decreased significantly in Zambia in the last decade. The malaria transmission is influenced by environmental variables. Incorporation of environmental variables in models of malaria transmission likely improves model fit and predicts probable trends in malaria disease. This work is based on the hypothesis that remotely-sensed environmental factors, including nocturnal dew point, are associated with malaria transmission and sustain foci of transmission during the low transmission season in the Southern Province of Zambia. Thirty-eight rural health centres in Southern Province, Zambia were divided into three zones based on transmission patterns. Correlations between weekly malaria cases and remotely-sensed nocturnal dew point, nocturnal land surface temperature as well as vegetation indices and rainfall were evaluated in time-series analyses from 2012 week 19 to 2013 week 36. Zonal as well as clinic-based, multivariate, autoregressive, integrated, moving average (ARIMAX) models implementing environmental variables were developed to model transmission in 2011 week 19 to 2012 week 18 and forecast transmission in 2013 week 37 to week 41. During the dry, low transmission season significantly higher vegetation indices, nocturnal land surface temperature and nocturnal dew point were associated with the areas of higher transmission. Environmental variables improved ARIMAX models. Dew point and normalized differentiated vegetation index were significant predictors and improved all zonal transmission models. In the high-transmission zone, this was also seen for land surface temperature. Clinic models were improved by adding dew point and land surface temperature as well as normalized differentiated vegetation index. The mean average error of prediction for ARIMAX models ranged from 0.7 to 33.5%. Forecasts of malaria incidence were valid for three out of five rural health centres; however, with poor results at the zonal level. In this

  19. Densimetry for the Quantification of Sorption Phenomena on Nonporous Media Near the Dew Point of Fluid Mixtures.

    PubMed

    Richter, Markus; McLinden, Mark O

    2017-07-21

    Phase equilibria of fluid mixtures are important in numerous industrial applications and are, thus, a major focus of thermophysical property research. Improved data, particularly along the dew line, are needed to improve model predictions. Here we present experimental results utilizing highly accurate densimetry to quantify the effects of sorption and capillary condensation, which exert a distorting influence on measured properties near the dew line. We investigate the (pressure, density, temperature, composition) behaviour of binary (CH 4  + C 3 H 8 ) and (Ar + CO 2 ) mixtures over the temperature range from (248.15 to 273.15) K starting at low pressures and increasing in pressure towards the dew point along isotherms. Three distinct regions are observed: (1) minor sorption effects in micropores at low pressures; (2) capillary condensation followed by wetting in macro-scale surface scratches beginning approximately 2% below the dew-point pressure; (3) bulk condensation. We hypothesize that the true dew point lies within the second region.

  20. BILATERAL KEY COMPARISON SIM.T-K6.5 ON HUMIDITY STANDARDS IN THE DEW/FROST-POINT TEMPERATURE RANGE FROM −30 °C TO +20 °C

    PubMed Central

    Meyer, C.W.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures over the range −30 °C TO +20 °C was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica), between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining the degree of equivalence between the dew/frost-point standards of NIST and LACOMET. PMID:28066029

  1. Final report on CCT-K6: Comparison of local realisations of dew-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Bell, S.; Stevens, M.; Abe, H.; Benyon, R.; Bosma, R.; Fernicola, V.; Heinonen, M.; Huang, P.; Kitano, H.; Li, Z.; Nielsen, J.; Ochi, N.; Podmurnaya, O. A.; Scace, G.; Smorgon, D.; Vicente, T.; Vinge, A. F.; Wang, L.; Yi, H.

    2015-01-01

    A key comparison in dew-point temperature was carried out among the national standards held by NPL (pilot), NMIJ, INTA, VSL, INRIM, MIKES, NIST, NIM, VNIIFTRI-ESB and NMC. A pair of condensation-principle dew-point hygrometers was circulated and used to compare the local realisations of dew point for participant humidity generators in the range -50 °C to +20 °C. The duration of the comparison was prolonged by numerous problems with the hygrometers, requiring some repairs, and several additional check measurements by the pilot. Despite the problems and the extended timescale, the comparison was effective in providing evidence of equivalence. Agreement with the key comparison reference value was achieved in the majority of cases, and bilateral degrees of equivalence are also reported. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  2. Growth responses of male broilers subjected to increasing air velocities at high ambient temperatures and a high dew point.

    PubMed

    Dozier, W A; Lott, B D; Branton, S L

    2005-06-01

    This study examined live performance responses of male broilers to increasing air velocity of 120 and 180 m/min reared under high cyclic temperatures (25-35-25 degrees C) with a 23 degrees C dew point from 21 to 49 d. Birds were reared in an environmental facility containing 2 wind tunnels (4 pens/tunnel) and 6 floor pens (control). At 21 d, 53 birds were placed in each pen of the wind tunnels and control group, respectively, and growth performance was determined weekly. Increasing air velocity from 120 to 180 m/min improved BW and BW gain from 29 to 35, 36 to 42, and 43 to 49 d of age leading to a cumulative advantage of 287 g in BW gain and a 10-point difference in feed conversion from 21 to 49 d of age. Subjecting birds to air velocity improved growth rate, feed consumption, and feed conversion at each weekly interval from 28 to 49 d over the control birds. These results indicate that male broilers approximating 2.0 to 3.0 kg respond to an air velocity of 180 m/min when exposed to high cyclic temperatures.

  3. Validation of a dew-point generator for pressures up to 6 MPa using nitrogen and air

    NASA Astrophysics Data System (ADS)

    Bosma, R.; Mutter, D.; Peruzzi, A.

    2012-08-01

    A new primary humidity standard was developed at VSL that, in addition to ordinary operation with air and nitrogen at atmospheric pressure, can be operated with other carrier gases such as natural gas at pressures up to 6 MPa and SF6 at pressures up to 1 MPa. The temperature range of the standard is from -80 °C to +20 °C. In this paper, we report the validation of the new primary dew-point generator in the temperature range -41 °C to +5 °C and the pressure range 0.1 MPa to 6 MPa using nitrogen and air. For the validation the flow through the dew-point generator was varied up to 10 l min-1 (at 23 °C and 1013 hPa) and the dew point of the gas entering the generator was varied up to 15 °C above the dew point exiting the generator. The validation results showed that the new generator, over the tested temperature and pressure range, can be used with a standard uncertainty of 0.02 °C frost/dew point. The measurements used for the validation at -41 °C and -20 °C with nitrogen and at +5 °C with air were also used to calculate the enhancement factor at pressures up to 6 MPa. For +5 °C the differences between the measured and literature values were compatible with the respective uncertainties. For -41 °C and -20 °C they were compatible only up to 3 MPa. At 6 MPa a discrepancy was observed.

  4. Remotely-sensed, nocturnal, dew point correlates with malaria transmission in Southern Province, Zambia: a time-series study

    PubMed Central

    2014-01-01

    Background Plasmodium falciparum transmission has decreased significantly in Zambia in the last decade. The malaria transmission is influenced by environmental variables. Incorporation of environmental variables in models of malaria transmission likely improves model fit and predicts probable trends in malaria disease. This work is based on the hypothesis that remotely-sensed environmental factors, including nocturnal dew point, are associated with malaria transmission and sustain foci of transmission during the low transmission season in the Southern Province of Zambia. Methods Thirty-eight rural health centres in Southern Province, Zambia were divided into three zones based on transmission patterns. Correlations between weekly malaria cases and remotely-sensed nocturnal dew point, nocturnal land surface temperature as well as vegetation indices and rainfall were evaluated in time-series analyses from 2012 week 19 to 2013 week 36. Zonal as well as clinic-based, multivariate, autoregressive, integrated, moving average (ARIMAX) models implementing environmental variables were developed to model transmission in 2011 week 19 to 2012 week 18 and forecast transmission in 2013 week 37 to week 41. Results During the dry, low transmission season significantly higher vegetation indices, nocturnal land surface temperature and nocturnal dew point were associated with the areas of higher transmission. Environmental variables improved ARIMAX models. Dew point and normalized differentiated vegetation index were significant predictors and improved all zonal transmission models. In the high-transmission zone, this was also seen for land surface temperature. Clinic models were improved by adding dew point and land surface temperature as well as normalized differentiated vegetation index. The mean average error of prediction for ARIMAX models ranged from 0.7 to 33.5%. Forecasts of malaria incidence were valid for three out of five rural health centres; however, with poor

  5. Spatial interpolation of hourly precipitation and dew point temperature for the identification of precipitation phase and hydrologic response in a mountainous catchment

    NASA Astrophysics Data System (ADS)

    Garen, D. C.; Kahl, A.; Marks, D. G.; Winstral, A. H.

    2012-12-01

    In mountainous catchments, it is well known that meteorological inputs, such as precipitation, air temperature, humidity, etc. vary greatly with elevation, spatial location, and time. Understanding and monitoring catchment inputs is necessary in characterizing and predicting hydrologic response to these inputs. This is true all of the time, but it is the most dramatically critical during large storms, when the input to the stream system due to rain and snowmelt creates the potential for flooding. Besides such crisis events, however, proper estimation of catchment inputs and their spatial distribution is also needed in more prosaic but no less important water and related resource management activities. The first objective of this study is to apply a geostatistical spatial interpolation technique (elevationally detrended kriging) to precipitation and dew point temperature on an hourly basis and explore its characteristics, accuracy, and other issues. The second objective is to use these spatial fields to determine precipitation phase (rain or snow) during a large, dynamic winter storm. The catchment studied is the data-rich Reynolds Creek Experimental Watershed near Boise, Idaho. As part of this analysis, precipitation-elevation lapse rates are examined for spatial and temporal consistency. A clear dependence of lapse rate on precipitation amount exists. Certain stations, however, are outliers from these relationships, showing that significant local effects can be present and raising the question of whether such stations should be used for spatial interpolation. Experiments with selecting subsets of stations demonstrate the importance of elevation range and spatial placement on the interpolated fields. Hourly spatial fields of precipitation and dew point temperature are used to distinguish precipitation phase during a large rain-on-snow storm in December 2005. This application demonstrates the feasibility of producing hourly spatial fields and the importance of doing

  6. New Primary Dew-Point Generators at HMI/FSB-LPM in the Range from -70 °C to +60 °C

    NASA Astrophysics Data System (ADS)

    Zvizdic, Davor; Heinonen, Martti; Sestan, Danijel

    2012-09-01

    To extend the dew-point range and to improve the uncertainties of the humidity scale realization at HMI/FSB-LPM, new primary low- and high-range dew-point generators were developed and implemented in cooperation with MIKES, in 2009 through EUROMET Project No. 912. The low-range saturator is designed for primary realization of the dew-point temperature scale from -70 °C to + 5 °C, while the high-range saturator covers the range from 1 °C to 60 °C. The system is designed as a single-pressure, single-pass dew-point generator. MIKES designed and constructed both the saturators to be implemented in dew-point calibration systems at LPM. The LPM took care of purchasing and adapting liquid baths, of implementing the temperature and pressure measurement equipment appropriate for use in the systems, and development of gas preparation and flow control systems as well as of the computer-based automated data acquisition. The principle and the design of the generator are described in detail and schematically depicted. The tests were performed at MIKES to investigate how close both the saturators are to an ideal saturator. Results of the tests show that both the saturators are efficient enough for a primary realization of the dew-point temperature scale from -70 °C to + 60 °C, in the specified flow-rate ranges. The estimated standard uncertainties due to the non-ideal saturation efficiency are between 0.02 °C and 0.05 °C.

  7. Effects of dew point on selective oxidation of TRIP steels containing Si, Mn, and B

    NASA Astrophysics Data System (ADS)

    Lee, Suk-Kyu; Kim, Jong-Sang; Choi, Jin-Won; Kang, Namhyun; Cho, Kyung-Mox

    2011-04-01

    The selective oxidation of Si, Mn, and B on TRIP steel surfaces is a widely known phenomenon that occurs during heat treatment. However, the relationship between oxide formation and the annealing factors is not completely understood. This study examines the effect of the annealing conditions (dew point and annealing temperature) on oxide formation. A low dew point of -40 °C leads to the formation of Si-based oxides on the surface. A high dew point of -20 °C changes the oxide type to Mn-based oxides because the formation of Si oxides on the surface is suppressed by internal oxidation. Mn-based oxides exhibit superior wettability due to aluminothermic reduction during galvanizing.

  8. A MEMS-based super fast dew point hygrometer—construction and medical applications

    NASA Astrophysics Data System (ADS)

    Jachowicz, Ryszard S.; Weremczuk, Jerzy; Paczesny, Daniel; Tarapata, Grzegorz

    2009-12-01

    The paper shows how MEMS (micro-electro-mechanical system) technology and a modified principle of fast temperature control (by heat injection instead of careful control of cooling) can considerably improve the dynamic parameters of dew point hygrometers. Some aspects of MEMS-type integrated sensor construction and technology, whole measurement system design, the control algorithm to run the system as well as empirical dynamic parameters from the tests are discussed too. The hygrometer can easily obtain five to six measurements per second with an uncertainty of less than 0.3 K. The meter range is between -10 °C and 40 °C dew point. In the second part of the paper (section 2), two different successful applications in medicine based on fast humidity measurements have been discussed. Some specific constructions of these super fast dew point hygrometers based on a MEMS sensor as well as limited empirical results from clinical tests have been reported too.

  9. Bilateral key comparison SIM.T-K6.5 on humidity standards in the dew/frost-point temperature range from -30 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C.; Solano, A.

    2016-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Laboratorio Costarricense de Metrología (LACOMET, Costa Rica) between February 2015 and August 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and LACOMET and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and LACOMET. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  10. Bilateral key comparison SIM.T-K6.2 on humidity standards in the dew/frost-point temperature range from -20 °c to 20 °c

    NASA Astrophysics Data System (ADS)

    Huang, P. H.; Meyer, C. W.; Martines-López, E.; Dávila Pacheco, J. A.; Méndez-Lango, E.

    2014-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Centro Nacional de Metrologia (CENAM, Mexico) between July 2008 and December 2008. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and CENAM and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and CENAM. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Dew-point hygrometry system for measurement of evaporative water loss in infants.

    PubMed

    Ariagno, R L; Glotzbach, S F; Baldwin, R B; Rector, D M; Bowley, S M; Moffat, R J

    1997-03-01

    Evaporation of water from the skin is an important mechanism in thermal homeostasis. Resistance hygrometry, in which the water vapor pressure gradient above the skin surface is calculated, has been the measurement method of choice in the majority of pediatric investigations. However, resistance hygrometry is influenced by changes in ambient conditions such as relative humidity, surface temperature, and convection currents. We have developed a ventilated capsule method that minimized these potential sources of measurement error and that allowed second-by-second, long-term, continuous measurements of evaporative water loss in sleeping infants. Air with a controlled reference humidity (dew-point temperature = 0 degree C) is delivered to a small, lightweight skin capsule and mixed with the vapor on the surface of the skin. The dew point of the resulting mixture is measured by using a chilled mirror dew-point hygrometer. The system indicates leaks, is mobile, and is accurate within 2%, as determined by gravimetric calibration. Examples from a recording of a 13-wk-old full-term infant obtained by using the system give evaporative water loss rates of approximately 0.02 mgH2O.cm-2.min-1 for normothermic baseline conditions and values up to 0.4 mgH2O.cm-2. min-1 when the subject was being warmed. The system is effective for clinical investigations that require dynamic measurements of water loss.

  12. Transport-induced shifts in condensate dew-point and composition in multicomponent systems with chemical reaction

    NASA Technical Reports Server (NTRS)

    Rosner, D. E.; Nagarajan, R.

    1985-01-01

    Partial heterogeneous condensation phenomena in multicomponent reacting systems are analyzed taking into consideration the chemical element transport phenomena. It is demonstrated that the dew-point surface temperature in chemically reactive systems is not a purely thermodynamic quantity, but is influenced by the multicomponent diffusion and Soret-mass diffusion phenomena. Several distinct dew-points are shown to exist in such systems and, as a result of transport constraints, the 'sharp' locus between two chemically distinct condensates is systematically moved to a difference mainstream composition.

  13. [An automatic dew-point hygrometer making use of beta-ray backscattering (author's transl)].

    PubMed

    Matsumoto, S; Kobayashi, H

    1981-04-01

    A proportional control system was employed on this hygrometer. The hygrometer was used in a box in which the temperature and the humidity were constantly regulated. The range of measured dew-point was from -26 degrees C to 60 degrees C in the atmospheric temperature of 0 degree C to 60 degrees C, that was the relative humidity of 12% to 100%, and the accuracy of the measurement was +/- 1 degree C.

  14. Determination of the dew point and the frost point below 0 degrees C making use of the beta-ray backscattering and the electric conductivity on the narrow surface of insulated layer.

    PubMed

    Matsumoto, S; Kobayashi, H

    1979-10-15

    It is necessary to distinguish between the dew point and the frost point below 0 degrees C. The freezing of the dew and the melting of the frost are respectively detected by the rapid decrease and the increase of the conduction current on the narrow surface of insulated layer made of epoxy, 0.5 mm in width and 10 mm in length, on which the dew deposits. The dew point -9 degrees C and the frost point -8 degrees C in the humidity 21% at the temperature 13 degrees C are clearly distinguished in this method.

  15. Bilateral key comparison SIM.T-K6.1 on humidity standards in the dew/frost-point temperature range from -25 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Meyer, C. W.; Hill, K. D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the National Research Council (NRC, Canada) between December 2014 and April 2015. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and NRC and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and NRC. This paper is the final report of the comparison including analysis of the uncertainty of measurement results. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT WG-KC, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  16. The measurement of tiny dew droplets at the initial deposition stage and dew point using a phase-shift interference microscope

    NASA Astrophysics Data System (ADS)

    Shigeaki, Matsumoto

    2003-12-01

    The shape of a dew droplet deposited on the mirror surface of a copper plate was measured accurately using an interference microscope that employed a phase-shift technique. The microscope was constructed by adding a piezoelectric transducer to an interference microscope. A simple method that uses a conventional speaker horn and an optical fibre cable was used to depress any speckle noise. The shape of a dew droplet deposited at dew point on the plate surface with average roughness of 0.1 µm was measured with an accuracy of ± 3 nm. The mass of a tiny dew droplet could be determined from the volume of its shape and was of the order of 10-9 g. The total mass of a dew droplet deposited per unit area and the deposition velocity under a gentle wind were also obtained in a similar way. The total mass was of the order of 10-5 g cm-2 at the beginning of deposition and the deposition velocity ranged from 1 × 10-5 to 6 × 10-5 g cm-2 min-1 at room temperature.

  17. Final report: Bilateral key comparison SIM.T-K6.3 on humidity standards in the dew/frost-point temperature range from -30°C to 20°C

    NASA Astrophysics Data System (ADS)

    Huang, Peter; Meyer, Christopher; Brionizio, Julio D.

    2015-01-01

    A Regional Metrology Organization (RMO) Key Comparison of dew/frost point temperatures was carried out by the National Institute of Standards and Technology (NIST, USA) and the Instituto Nacional de Metrologia, Qualidade e Tecnologia (INMETRO, Brazil) between October 2009 and March 2010. The results of this comparison are reported here, along with descriptions of the humidity laboratory standards for NIST and INMETRO and the uncertainty budget for these standards. This report also describes the protocol for the comparison and presents the data acquired. The results are analyzed, determining degree of equivalence between the dew/frost-point standards of NIST and INMETRO. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  18. Estimation of precipitable water at different locations using surface dew-point

    NASA Astrophysics Data System (ADS)

    Abdel Wahab, M.; Sharif, T. A.

    1995-09-01

    The Reitan (1963) regression equation of the form ln w = a + bT d has been examined and tested to estimate precipitable water vapor content from the surface dew point temperature at different locations. The results of this study indicate that the slope b of the above equation has a constant value of 0.0681, while the intercept a changes rapidly with latitude. The use of the variable intercept technique can improve the estimated result by about 2%.

  19. Investigation of Primary Dew-Point Saturator Efficiency in Two Different Thermal Environments

    NASA Astrophysics Data System (ADS)

    Zvizdic, D.; Heinonen, M.; Sestan, D.

    2015-08-01

    The aim of this paper is to describe the evaluation process of the performance of the low-range saturator (LRS), when exposed to two different thermal environments. The examined saturator was designed, built, and tested at MIKES (Centre for Metrology and Accreditation, Finland), and then transported to the Laboratory for Process Measurement (LPM) in Croatia, where it was implemented in a new dew-point calibration system. The saturator works on a single-pressure-single-pass generation principle in the dew/frost-point temperature range between and . The purpose of the various tests performed at MIKES was to examine the efficiency and non-ideality of the saturator. As a test bath facility in Croatia differs from the one used in Finland, the same tests were repeated at LPM, and the effects of different thermal conditions on saturator performance were examined. Thermometers, pressure gauges, an air preparation system, and water for filling the saturator at LPM were also different than those used at MIKES. Results obtained by both laboratories indicate that the efficiency of the examined saturator was not affected either by the thermal conditions under which it was tested or by equipment used for the tests. Both laboratories concluded that LRS is efficient enough for a primary realization of the dew/frost-point temperature scale in the range from to , with flow rates between and . It is also shown that a considerable difference of the pre-saturator efficiency, indicated by two laboratories, did not have influence to the overall performance of the saturator. The results of the research are presented in graphical and tabular forms. This paper also gives a brief description of the design and operation principle of the investigated low-range saturator.

  20. The New LMK Primary Standard for Dew-Point Sensor Calibration: Evaluation of the High-Range Saturator Efficiency

    NASA Astrophysics Data System (ADS)

    Hudoklin, Domen; Drnovšek, Janko

    2008-10-01

    In the field of hygrometry, a primary dew-point standard can be realized according to several proven principles, such as single-pressure (1-P), two-pressure (2-P), or divided flow. Different realizations have been introduced by various national laboratories, each resulting in a stand-alone complex generation system. Recent trends in generator design favor the single-pressure principle without recirculation because it promises theoretically lower uncertainty and because it avoids problems regarding the leak tightness of the recirculation. Instead of recirculation, the efficiency of saturation, the key factor, is increased by preconditioning the inlet gas entering the saturator. For preconditioning, a presaturator or purifier is used to bring the dew point of the inlet stream close to the saturator temperature. The purpose of the paper is to identify the minimum requirements for the preconditioning system and the main saturator to assure efficient saturation for the LMK generator. Moreover, the aim is also to find out if the preconditioning system can be avoided despite the rather simple construction of the main saturator. If this proves to be the case, the generator design can be simplified while maintaining an accurate value of the generated dew point. Experiments were carried out within the scope of improving our existing primary generator in the above-ambient dew-point range up to +70°C. These results show the generated dew point is within the measurement uncertainty for any dew-point value of the inlet gas. Thus, the preconditioning subsystem can be avoided, which leads to a simplified generator design.

  1. KEY COMPARISON: Final report of APMP.T-K6 (original name APMP-IC-1-97): Comparison of humidity measurements using a dew point meter as a transfer standard

    NASA Astrophysics Data System (ADS)

    Li, Wang; Takahashi, C.; Hussain, F.; Hong, Yi; Nham, H. S.; Chan, K. H.; Lee, L. T.; Chahine, K.

    2007-01-01

    This APMP key comparison of humidity measurements using a dew point meter as a transfer standard was carried out among eight national metrology institutes from February 1999 to January 2001. The NMC/SPRING, Singapore was the pilot laboratory and a chilled mirror dew point meter offered by NMIJ was used as a transfer standard. The transfer standard was calibrated by each participating institute against local humidity standards in terms of frost and dew point temperature. Each institute selected its frost/dew point temperature calibration points within the range from -70 °C to 20 °C frost/dew point with 5 °C step. The majority of participating institutes measured from -60 °C to 20 °C frost/dew point and a simple mean evaluation was performed in this range. The differences between the institute values and the simple means for all participating institutes are within two standard deviations from the mean values. Bilateral equivalence was analysed in terms of pair difference and single parameter Quantified Demonstrated Equivalence. The results are presented in the report. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  2. Multi-channel fiber optic dew and humidity sensor

    NASA Astrophysics Data System (ADS)

    Limodehi, Hamid E.; Mozafari, Morteza; Amiri, Hesam; Légaré, François

    2018-03-01

    In this article, we introduce a multi-channel fiber optic dew and humidity sensor which works using a novel method based on relation between surface plasmon resonance (SPR) and water vapor condensation. The proposed sensor can instantly detect moisture or dew formation through its fiber optic channels, separately situated in different places. It enables to simultaneously measure the ambient Relative Humidity (RH) and dew point temperature of several environments with accuracy of 5%.

  3. Live performance of male broilers subjected to constant or increasing air velocities at moderate temperatures with a high dew point.

    PubMed

    Dozier, W A; Lott, B D; Branton, S L

    2005-08-01

    This study examined the effects of varying air velocities vs. a constant air velocity with a cyclic temperature curve of 25-30-25 degrees C and a dew point of 23 degrees C on broilers from 28 to 49 d of age. Four replicate trials were conducted. In each trial, 742 male broilers were randomly allocated to 6 floor pens or 2 air velocity tunnels, with each tunnel consisting of 4 pens. Bird density, feeder, and waterer space were similar across all pens (53 birds/ pen; 0.07 m2/bird). The treatments were control (still air), constant air velocity of 120 m/min, and increasing air velocity (90 m/min from 28 to 35 d, 120 m/min from 36 to 42 d, and 180 m/min from 43 to 49 d). Birds grown in a still air environment gained less weight, consumed less feed, and converted feed less efficiently between 28 and 49 d than birds subjected to moving air (constant or increasing). Growth responses between the air velocity treatments were similar from 28 to 35 and 36 to 42 d of age. Increasing air velocity to 180 m/min improved (P < or = 0.02) the growth rate of broilers from 43 to 49 d of age over birds receiving an air velocity of 120 m/min, but the incidence of mortality was not affected. These results provide evidence that increasing air velocity from 120 to 180 m/min is beneficial to broilers weighing 2.5 kg or greater when exposed to moderate temperatures.

  4. Evaluation of the Long-Term Stability and Temperature Coefficient of Dew-Point Hygrometers

    NASA Astrophysics Data System (ADS)

    Benyon, R.; Vicente, T.; Hernández, P.; De Rivas, L.; Conde, F.

    2012-09-01

    The continuous quest for improved specifications of optical dew-point hygrometers has raised customer expectations on the performance of these devices. In the absence of a long calibration history, users with a limited prior experience in the measurement of humidity, place reliance on manufacturer specifications to estimate long-term stability. While this might be reasonable in the case of measurement of electrical quantities, in humidity it can lead to optimistic estimations of uncertainty. This article reports a study of the long-term stability of some hygrometers and the analysis of their performance as monitored through regular calibration. The results of the investigations provide some typical, realistic uncertainties associated with the long-term stability of instruments used in calibration and testing laboratories. Together, these uncertainties can help in establishing initial contributions in uncertainty budgets, as well as in setting the minimum calibration requirements, based on the evaluation of dominant influence quantities.

  5. Smart textile plasmonic fiber dew sensors.

    PubMed

    Esmaeilzadeh, Hamid; Rivard, Maxime; Arzi, Ezatollah; Légaré, François; Hassani, Alireza

    2015-06-01

    We propose a novel Surface Plasmon Resonance (SPR)-based sensor that detects dew formation in optical fiber-based smart textiles. The proposed SPR sensor facilitates the observation of two phenomena: condensation of moisture and evaporation of water molecules in air. This sensor detects dew formation in less than 0.25 s, and determines dew point temperature with an accuracy of 4%. It can be used to monitor water layer depth changes during dew formation and evaporation in the range of a plasmon depth probe, i.e., 250 nm, with a resolution of 7 nm. Further, it facilitates estimation of the relative humidity of a medium over a dynamic range of 30% to 70% by measuring the evaporation time via the plasmon depth probe.

  6. Analysis of Multicomponent Adsorption Close to a Dew Point.

    PubMed

    Shapiro; Stenby

    1998-10-15

    We develop the potential theory of multicomponent adsorption close to a dew point. The approach is based on an asymptotic adsorption equation (AAE) which is valid in a vicinity of the dew point. By this equation the thickness of the liquid film is expressed through thermodynamic characteristics of the bulk phase. The AAE makes it possible to study adsorption in the regions of both the normal and the retrograde condensation. A simple correlation of the Kelvin radius for capillary condensation and the thickness of the adsorbed film is established. Numerical testing shows good agreement between the AAE and the direct calculations, even if the mixture is not close to a dew point. Copyright 1998 Academic Press.

  7. Measurement of evaporative water loss in small animals by dew-point hygrometry.

    PubMed

    Bernstein, M H; Hudson, D M; Stearns, J M; Hoyt, R W

    1977-08-01

    This paper presents the procedures and equations to be utilized for measurement of evaporative water loss (mw), by use of the dew-point hygrometer, in small animals exposed to air containing water vapor in an open-flow system. The system accounted accurately for the water evaporated from a bubble flask. In addition, hygrometric measurements of pulmocutaneous mw in pigeons (Columba livia, mean mass 0.31 kg) agreed closely with simultaneous gravimetric measurements, utilizing a desiccant in the sample stream, in a manner independently of air temperature (Ta, 20 or 40 degrees C), ambient water vapor pressure (PW, 4-16 10(2) Pa), or mw (5-66 mg-min-1). Evaporation in pigeons was independent of PW at 20 degrees C, but increased with decreasing PW at 40 degrees C, suggesting differences in ventilatory adjustments to changes in PW at the two temperatures.

  8. KEY COMPARISON Report to the CCT on key comparison EUROMET.T-K6 (EUROMET Project no. 621): Comparison of the realizations of local dew/frost-point temperature scales in the range -50 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti

    2010-01-01

    The first humidity CIPM key comparison, CCT-K6, will be completed in 2010. The corresponding European regional key comparison, EUROMET.T-K6, was carried out in 2004 to 2008. National metrology institutes from 24 countries participated in the comparison. The comparison covered the dew-point temperature range from -50 °C to +20 °C. It was organized as three parallel loops with two specially manufactured precision chilled mirror hygrometers as transfer standards in each loop. The comparison scheme was designed to ensure high quality results with evenly spread workload for the participants. MIKES was coordinating the project. This report presents the results of the comparison and provides detailed information on the measurements performed by all participating laboratories and the analysis of the results. Conclusions on the equivalence of the dew-point temperature standards are drawn on the basis of calculated bilateral degrees of equivalence and deviations from EURAMET comparison reference values (ERV). Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (MRA).

  9. New methods of subcooled water recognition in dew point hygrometers

    NASA Astrophysics Data System (ADS)

    Weremczuk, Jerzy; Jachowicz, Ryszard

    2001-08-01

    Two new methods of sub-cooled water recognition in dew point hygrometers are presented in this paper. The first one- impedance method use a new semiconductor mirror in which the dew point detector, the thermometer and the heaters were integrated all together. The second one an optical method based on a multi-section optical detector is discussed in the report. Experimental results of both methods are shown. New types of dew pont hydrometers of ability to recognized sub-cooled water were proposed.

  10. Simulating sunflower canopy temperatures to infer root-zone soil water potential

    NASA Technical Reports Server (NTRS)

    Choudhury, B. J.; Idso, S. B.

    1983-01-01

    A soil-plant-atmosphere model for sunflower (Helianthus annuus L.), together with clear sky weather data for several days, is used to study the relationship between canopy temperature and root-zone soil water potential. Considering the empirical dependence of stomatal resistance on insolation, air temperature and leaf water potential, a continuity equation for water flux in the soil-plant-atmosphere system is solved for the leaf water potential. The transpirational flux is calculated using Monteith's combination equation, while the canopy temperature is calculated from the energy balance equation. The simulation shows that, at high soil water potentials, canopy temperature is determined primarily by air and dew point temperatures. These results agree with an empirically derived linear regression equation relating canopy-air temperature differential to air vapor pressure deficit. The model predictions of leaf water potential are also in agreement with observations, indicating that measurements of canopy temperature together with a knowledge of air and dew point temperatures can provide a reliable estimate of the root-zone soil water potential.

  11. Development of a Dew-Point Generator for Gases Other than Air and Nitrogen and Pressures up to 6 MPa

    NASA Astrophysics Data System (ADS)

    Bosma, R.; Peruzzi, A.

    2012-09-01

    A new primary humidity standard is currently being developed at VSL that, in addition to ordinary operation with air and nitrogen at atmospheric pressure, can be operated also with special carrier gases such as natural gas and SF6 and at pressures up to 6 MPa. In this paper, the design and construction of this new primary dew-point generator and the preliminary tests performed on the generator are reported. The results of the first efficiency tests, performed for the dew-point temperature range from -50 °C to 20°C, for pressures up to 0.7MPa and for carrier gas flow rates up to 4L· min-1, showed satisfactory generator performance when used in the single-pass mode, i.e., with no recirculation of the carrier gas.

  12. Memory persistency and nonlinearity in daily mean dew point across India

    NASA Astrophysics Data System (ADS)

    Ray, Rajdeep; Khondekar, Mofazzal Hossain; Ghosh, Koushik; Bhattacharjee, Anup Kumar

    2016-04-01

    Enterprising endeavour has been taken in this work to realize and estimate the persistence in memory of the daily mean dew point time series obtained from seven different weather stations viz. Kolkata, Chennai (Madras), New Delhi, Mumbai (Bombay), Bhopal, Agartala and Ahmedabad representing different geographical zones in India. Hurst exponent values reveal an anti-persistent behaviour of these dew point series. To affirm the Hurst exponent values, five different scaling methods have been used and the corresponding results are compared to synthesize a finer and reliable conclusion out of it. The present analysis also bespeaks that the variation in daily mean dew point is governed by a non-stationary process with stationary increments. The delay vector variance (DVV) method has been exploited to investigate nonlinearity, and the present calculation confirms the presence of deterministic nonlinear profile in the daily mean dew point time series of the seven stations.

  13. Using dew points to estimate savings during a planned cooling shutdown

    NASA Astrophysics Data System (ADS)

    Friedlein, Matthew T.; Changnon, David; Musselman, Eric; Zielinski, Jeff

    2005-12-01

    In an effort to save money during the summer of 2003, Northern Illinois University (NIU) administrators instituted a four-day working week and stopped air conditioning buildings for the three-day weekends (Friday through Sunday). Shutting down the air conditioning systems caused a noticeable drop in electricity usage for that part of the campus that features in our study, with estimated total electricity savings of 1,268,492 kilowatt-hours or 17% of the average usage during that eight-week period. NIU's air conditioning systems, which relied on evaporative cooling to function, were sensitive to dew point levels. Greatest savings during the shutdown period occurred on days with higher dew points. An examination of the regional dew point climatology (1959 2003) indicated that the average summer daily dew point for 2003 was 14.9°C (58.8°F), which fell in the lowest 20% of the distribution. Based on the relationship between daily average dew points and electrical usage, a predictive model that could estimate electrical daily savings was created. This model suggests that electrical savings related to any future three-day shutdowns over summer could be much greater in more humid summers. Studies like this demonstrate the potential value of applying climatological information and of integrating this information into practical decision-making.

  14. Feedback dew-point sensor utilizing optimally cut plastic optical fibres

    NASA Astrophysics Data System (ADS)

    Hadjiloucas, S.; Irvine, J.; Keating, D. A.

    2000-01-01

    A plastic optical fibre reflectance sensor that makes full use of the critical angle of the fibres is implemented to monitor dew formation on a Peltier-cooled reflector surface. The optical configuration permits isolation of optoelectronic components from the sensing head and better light coupling between the reflector and the detecting fibre, giving a better signal of the onset of dew formation on the reflector. Continuous monitoring of the rate of change in reflectance as well as the absolute reflectance signals, the use of a novel polymethyl-methacrylate-coated hydrophobic film reflector on the Peltier element and the application of feedback around the point of dew formation, further reduces the possibility of contamination of the sensor head. Under closed-loop operation, the sensor is capable of cycling around the point of dew formation at a frequency of 2.5 Hz.

  15. Simulating soybean canopy temperature as affected by weather variables and soil water potential

    NASA Technical Reports Server (NTRS)

    Choudhury, B. J.

    1982-01-01

    Hourly weather data for several clear sky days during summer at Phoenix and Baltimore which covered a wide range of variables were used with a plant atmosphere model to simulate soybean (Glycine max L.) leaf water potential, stomatal resistance and canopy temperature at various soil water potentials. The air and dew point temperatures were found to be the significant weather variables affecting the canopy temperatures. Under identical weather conditions, the model gives a lower canopy temperature for a soybean crop with a higher rooting density. A knowledge of crop rooting density, in addition to air and dew point temperatures is needed in interpreting infrared radiometric observations for soil water status. The observed dependence of stomatal resistance on the vapor pressure deficit and soil water potential is fairly well represented. Analysis of the simulated leaf water potentials indicates overestimation, possibly due to differences in the cultivars.

  16. Effects of temperature at constant air dew point on leaf carboxylation efficiency and CO2 compensation point of different leaf types.

    PubMed

    Weber, J A; Tenhunen, J D; Lange, O L

    1985-09-01

    The effect of temperature on photosynthesis at constant water-vapor pressure in the air was investigated using two sclerophyll species, Arbutus unedo and Quercus suber, and one mesophytic species, Spinacia oleracea. Photosynthesis and transpiration were measured over a range of temperatures, 20-39° C. The external concentration of CO2 was varied from 340 μbar to near CO2 compensation. The initial slope (carboxylation efficiency, CE) of the photosynthetic response to intercellular CO2 concentration, the CO2 compensation point (Γ), and the extrapolated rate of CO2 released into CO2-free air (R i) were calculated. At an external CO2 concentration of 320-340 μbar CO2, photosynthesis decreased with temperature in all species. The effect of temperature on Γ was similar in all species. While CE in S. oleracea changed little with temperature, CE decreased by 50% in Q. suber as temperature increased from 25 to 34° C. Arbutus unedo also exhibited a decrease in CE at higher temperatures but not as marked as Q. suber. The absolut value of R i increased with temperature in S. oleracea, while changing little or decreasing in the sclerophylls. Variations in Γ and R i of the sclerophyll species are not consistent with greater increase of respiration with temperature in the light in these species compared with S. oleracea.

  17. Dew point measurement technique utilizing fiber cut reflection

    NASA Astrophysics Data System (ADS)

    Kostritskii, S. M.; Dikevich, A. A.; Korkishko, Yu. N.; Fedorov, V. A.

    2009-05-01

    The fiber optical dew point hygrometer based on change of reflection coefficient for fiber cut has been developed and examined. We proposed and verified the model of condensation detector functioning principle. Experimental frost point measurements on air with different frost points have been performed.

  18. Measurement of dew droplets in initial deposition at dew point by using a phase-shift interference microscope

    NASA Astrophysics Data System (ADS)

    Matsumoto, Shigeaki; Toyooka, Satoru; Hoshino, Mitsuo

    2002-09-01

    In order to measure the total mass per unit area of dew droplets deposited on a metal plate in the dew-point hygrometer, the shape of a dew droplet deposited on a copper plate was measured accurately by using an interference microscope that employed a phase-shift technique. The microscope was constructed by adding a piezoelectric transducer to an usual interference microscope. A simple method that uses a conventional speaker horn and an optical fiber cable was introduced to depress speckle noise. The shape of a dew droplet deposited on the copper plate surface with 0.1 μm in average roughness was measured with an accuracy of +/-3nm. The mass of a dew droplet could be calculated numerically from the volume of its shape and was of the order of 10-9 g. The total mass of dew droplets deposited per unit area and the deposition velocity were obtained under a gentle wind. The total mass was the order of 10-5 g/cm2 at the beginning of deposition and the deposition velocity was ranged from 2x10-6 to 6x10-5 g/cm2.min.

  19. Satellite-derived vertical profiles of temperature and dew point for mesoscale weather forecast

    NASA Astrophysics Data System (ADS)

    Masselink, Thomas; Schluessel, P.

    1995-12-01

    Weather forecast-models need spatially high resolutioned vertical profiles of temperature and dewpoint for their initialisation. These profiles can be supplied by a combination of data from the Tiros-N Operational Vertical Sounder (TOVS) and the imaging Advanced Very High Resolution Radiometer (AVHRR) on board the NOAA polar orbiting sate!- lites. In cloudy cases the profiles derived from TOVS data only are of insufficient accuracy. The stanthrd deviations from radiosonde ascents or numerical weather analyses likely exceed 2 K in temperature and 5Kin dewpoint profiles. It will be shown that additional cloud information as retrieved from AVHIRR allows a significant improvement in theaccuracy of vertical profiles. The International TOVS Processing Package (ITPP) is coupled to an algorithm package called AVHRR Processing scheme Over cLouds, Land and Ocean (APOLLO) where parameters like cloud fraction and cloud-top temperature are determined with higher accuracy than obtained from TOVS retrieval alone. Furthermore, a split-window technique is applied to the cloud-free AVHRR imagery in order to derive more accurate surface temperatures than can be obtained from the pure TOVS retrieval. First results of the impact of AVHRR cloud detection on the quality of the profiles are presented. The temperature and humidity profiles of different retrieval approaches are validated against analyses of the European Centre for Medium-Range Weatherforecasts.

  20. Environmental dew point and skin and lip weathering.

    PubMed

    Devillers, C; Piérard, G E; Quatresooz, P; Piérard, S

    2010-05-01

    Xerosis represents a physiological response of the stratum corneum (SC) to environmental threats. The influence of the environmental dew point (DP) is not fully understood. This parameter is the air temperature at which the relative humidity is maximum. This study aimed to assess the relationship between the environmental DP and the water-holding capacity of the skin and lower lip vermilion. For comparison, SC property was evaluated after occlusive application of cooled and uncooled hydrogel pads. Electrometric measurements using a dermal phase meter (DPM) device were performed on the back of the hands, the cheeks and the lower lip of 40 healthy menopausal women. Assessments were performed in the outdoor conditions during winter and spring. The same measurements were recorded after hydrogel pads, at room temperature or cooled to 4 degrees C, were placed for 15 min on the test sites. The environmental DP was recorded at each evaluation time. The SC water-holding capacity was discretely influenced by the DP. In the open-air environmental conditions, a positive linear relationship was found on the cheeks between the DP and DPM values. The relationship was weaker on the lips. Conversely, a consistent increase in DPM values was recorded immediately after removal of the cooled and uncooled hydrogel pads. The observations made in the open-air testing conditions are consistent with the predicted events following the Arrhenius law. By contrast, the combination of cooling and occlusion by the hydrogel pads is responsible for the reverse effect on the SC.

  1. Dew point fast measurement in organic vapor mixtures using quartz resonant sensor

    NASA Astrophysics Data System (ADS)

    Nie, Jing; Liu, Jia; Meng, Xiaofeng

    2017-01-01

    A fast dew point sensor has been developed for organic vapor mixtures by using the quartz crystal with sensitive circuits. The sensor consists of the quartz crystal and a cooler device. Proactive approach is taken to produce condensation on the surface of the quartz crystal, and it will lead to a change in electrical features of the quartz crystal. The cessation of oscillation was measured because this phenomenon is caused by dew condensation. Such a phenomenon can be used to detect the dew point. This method exploits the high sensitivity of the quartz crystal but without frequency measurement and also retains the stability of the resonant circuit. It is strongly anti-interfered. Its performance was evaluated with acetone-methanol mixtures under different pressures. The results were compared with the dew points predicted from the universal quasi-chemical equation to evaluate the performance of the proposed sensor. Though the maximum deviations of the sensor are less than 1.1 °C, it still has a fast response time with a recovery time of less than 10 s, providing an excellent dehumidifying performance.

  2. Dew point fast measurement in organic vapor mixtures using quartz resonant sensor.

    PubMed

    Nie, Jing; Liu, Jia; Meng, Xiaofeng

    2017-01-01

    A fast dew point sensor has been developed for organic vapor mixtures by using the quartz crystal with sensitive circuits. The sensor consists of the quartz crystal and a cooler device. Proactive approach is taken to produce condensation on the surface of the quartz crystal, and it will lead to a change in electrical features of the quartz crystal. The cessation of oscillation was measured because this phenomenon is caused by dew condensation. Such a phenomenon can be used to detect the dew point. This method exploits the high sensitivity of the quartz crystal but without frequency measurement and also retains the stability of the resonant circuit. It is strongly anti-interfered. Its performance was evaluated with acetone-methanol mixtures under different pressures. The results were compared with the dew points predicted from the universal quasi-chemical equation to evaluate the performance of the proposed sensor. Though the maximum deviations of the sensor are less than 1.1 °C, it still has a fast response time with a recovery time of less than 10 s, providing an excellent dehumidifying performance.

  3. Use of dew-point detection for quantitative measurement of sweating rate

    NASA Technical Reports Server (NTRS)

    Brengelmann, G. L.; Mckeag, M.; Rowell, L. B.

    1975-01-01

    A method of measuring sweat rate (SR) based on detection of dew point (DP) is proposed which has advantages that may be attractive to other laboratories concerned with recording SR from selected areas of skin. It is similar to other methods in that dry gas is passed through a capsule which isolates several square centimeters of skin surface. The difference is in the means of determining how much gaseous water is carried off in the effluent moist gas. The DP detector used is free of the drawbacks of previous devices. DP is obtained through the fundamental technique of determining the temperature at which condensate forms on a mirror. Variations in DP are tracked rapidly, and accurately (+ or - 0.8 C nominal, sensitivity + or - 0.05 C) over a wide range ( -40 C to +50 C) without measurable hysteresis. The detector asembly is rugged and readily opened for cleaning and inspection.

  4. Miniature Fixed Points as Temperature Standards for In Situ Calibration of Temperature Sensors

    NASA Astrophysics Data System (ADS)

    Hao, X. P.; Sun, J. P.; Xu, C. Y.; Wen, P.; Song, J.; Xu, M.; Gong, L. Y.; Ding, L.; Liu, Z. L.

    2017-06-01

    Miniature Ga and Ga-In alloy fixed points as temperature standards are developed at National Institute of Metrology, China for the in situ calibration of temperature sensors. A quasi-adiabatic vacuum measurement system is constructed to study the phase-change plateaus of the fixed points. The system comprises a high-stability bath, a quasi-adiabatic vacuum chamber and a temperature control and measurement system. The melting plateau of the Ga fixed point is longer than 2 h at 0.008 W. The standard deviation of the melting temperature of the Ga and Ga-In alloy fixed points is better than 2 mK. The results suggest that the melting temperature of the Ga or Ga-In alloy fixed points is linearly related with the heating power.

  5. Outdoor temperature is associated with serum HDL and LDL.

    PubMed

    Halonen, Jaana I; Zanobetti, Antonella; Sparrow, David; Vokonas, Pantel S; Schwartz, Joel

    2011-02-01

    While exposures to high and low air temperatures are associated with cardiovascular mortality, the underlying mechanisms are poorly understood. The risk factors for cardiovascular disease include high levels of total cholesterol and low-density lipoprotein (LDL), and low levels of high-density lipoprotein (HDL). We investigated whether temperature was associated with changes in circulating lipid levels, and whether this might explain part of the association with increased cardiovascular events. The study cohort consisted of 478 men in the greater Boston area with a mean age of 74.2 years. They visited the clinic every 3-5 years between 1995 and 2008 for physical examination and to complete questionnaires. We excluded from analyses all men taking statin medication and all days with missing data, resulting in a total of 862 visits. Associations between three temperature variables (ambient, apparent, and dew point temperature) and serum lipid levels (total cholesterol, HDL, LDL, and triglycerides) were studied with linear mixed models that included possible confounders such as air pollution and a random intercept for each subject. We found that HDL decreased -1.76% (95% CI: from -3.17 to -0.32, lag 2 days), and -5.58% (95% CI: from -8.87 to -2.16, moving average of 4 weeks) for each 5°C increase in mean ambient temperature. For the same increase in mean ambient temperature, LDL increased by 1.74% (95% CI: 0.07-3.44, lag 1 day) and 1.87% (95% CI: 0.14-3.63, lag 2 days). These results were also similar for apparent and dew point temperatures. No changes were found in total cholesterol or triglycerides in relation to temperature increase. Changes in HDL and LDL levels associated with an increase in ambient temperature may be among the underlying mechanisms of temperature-related cardiovascular mortality. Copyright © 2010 Elsevier Inc. All rights reserved.

  6. Remote temperature-set-point controller

    DOEpatents

    Burke, W.F.; Winiecki, A.L.

    1984-10-17

    An instrument is described for carrying out mechanical strain tests on metallic samples with the addition of means for varying the temperature with strain. The instrument includes opposing arms and associated equipment for holding a sample and varying the mechanical strain on the sample through a plurality of cycles of increasing and decreasing strain within predetermined limits, circuitry for producing an output signal representative of the strain during the tests, apparatus including a a set point and a coil about the sample for providing a controlled temperature in the sample, and circuitry interconnected between the strain output signal and set point for varying the temperature of the sample linearly with strain during the tests.

  7. Remote temperature-set-point controller

    DOEpatents

    Burke, William F.; Winiecki, Alan L.

    1986-01-01

    An instrument for carrying out mechanical strain tests on metallic samples with the addition of an electrical system for varying the temperature with strain, the instrument including opposing arms and associated equipment for holding a sample and varying the mechanical strain on the sample through a plurality of cycles of increasing and decreasing strain within predetermined limits, circuitry for producing an output signal representative of the strain during the tests, apparatus including a set point and a coil about the sample for providing a controlled temperature in the sample, and circuitry interconnected between the strain output signal and set point for varying the temperature of the sample linearly with strain during the tests.

  8. Critical point analysis of phase envelope diagram

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Soetikno, Darmadi; Siagian, Ucok W. R.; Kusdiantara, Rudy, E-mail: rkusdiantara@s.itb.ac.id

    2014-03-24

    Phase diagram or phase envelope is a relation between temperature and pressure that shows the condition of equilibria between the different phases of chemical compounds, mixture of compounds, and solutions. Phase diagram is an important issue in chemical thermodynamics and hydrocarbon reservoir. It is very useful for process simulation, hydrocarbon reactor design, and petroleum engineering studies. It is constructed from the bubble line, dew line, and critical point. Bubble line and dew line are composed of bubble points and dew points, respectively. Bubble point is the first point at which the gas is formed when a liquid is heated. Meanwhile,more » dew point is the first point where the liquid is formed when the gas is cooled. Critical point is the point where all of the properties of gases and liquids are equal, such as temperature, pressure, amount of substance, and others. Critical point is very useful in fuel processing and dissolution of certain chemicals. Here in this paper, we will show the critical point analytically. Then, it will be compared with numerical calculations of Peng-Robinson equation by using Newton-Raphson method. As case studies, several hydrocarbon mixtures are simulated using by Matlab.« less

  9. Effects of dew deposition on transpiration and carbon uptake in leaves

    NASA Astrophysics Data System (ADS)

    Gerlein-Safdi, C.; Koohafkan, M.; Chung, M.; Rockwell, F. E.; Thompson, S. E.; Caylor, K. K.

    2017-12-01

    Dew deposition occurs in ecosystems worldwide, even in the driest deserts and in times of drought. Although some species absorb dew water directly via foliar uptake, a ubiquitous effect of dew on plant water balance is the interference of dew droplets with the leaf energy balance, which increases leaf albedo and emissivity and decreases leaf temperature through dew evaporation. Dew deposition frequency and amount are expected to be affected by changing environmental conditions, with unknown consequences for plant water stress and ecosystem carbon, water and energy fluxes. Here we present a simple leaf energy balance that characterizes the effect of deposition and the evaporation of dew on leaf energy balance, transpiration, and carbon uptake. The model is driven by five common meteorological variables and shows very good agreement with leaf wetness sensor data from the Blue Oak Ranch Reserve in California. We explore the tradeoffs between energy, water, and carbon balances for leaves of different sizes across a range of relative humidity, wind speed, and air temperature conditions. Our results show significant water savings from transpiration suppression up to 30% for leaf characteristic lengths of 50 cm due to the decrease in leaf temperature. C. 25% of water savings from transpiration suppression in smaller leaves arise from the effect of dew droplets on leaf albedo. CO2 assimilation is decreased by up to 15% by the presence of dew, except for bigger leaves in windspeed conditions below 1 m/s when an increase in assimilation is expected.

  10. Drier Air, Lower Temperatures, and Triggering of Paroxysmal Atrial Fibrillation

    PubMed Central

    Nguyen, Jennifer L.; Link, Mark S.; Luttmann-Gibson, Heike; Laden, Francine; Schwartz, Joel; Wessler, Benjamin S.; Mittleman, Murray A.; Gold, Diane R.; Dockery, Douglas W.

    2015-01-01

    Background The few previous studies on the onset of paroxysmal atrial fibrillation and meteorologic conditions have focused on outdoor temperature and hospital admissions, but hospital admissions are a crude indicator of atrial fibrillation incidence, and studies have found other weather measures in addition to temperature to be associated with cardiovascular outcomes. Methods Two hundred patients with dual chamber implantable cardioverter-defibrillators were enrolled and followed prospectively from 2006 to 2010 for new onset episodes of atrial fibrillation. The date and time of arrhythmia episodes documented by the implanted cardioverter-defibrillators were linked to meteorologic data and examined using a case-crossover analysis. We evaluated associations with outdoor temperature, apparent temperature, air pressure, and three measures of humidity (relative humidity, dew point, and absolute humidity). Results Of the 200 enrolled patients, 49 patients experienced 328 atrial fibrillation episodes lasting ≥30 seconds. Lower temperatures in the prior 48 hours were positively associated with atrial fibrillation. Lower absolute humidity (ie, drier air) had the strongest and most consistent association: each 0.5 g/m3 decrease in the prior 24 hours increased the odds of atrial fibrillation by 4% (95% confidence interval [CI]: 0%, 7%) and by 5% (95% CI: 2%, 8%) for exposure in the prior 2 hours. Results were similar for dew point but slightly weaker. Conclusions Recent exposure to drier air and lower temperatures were associated with the onset of atrial fibrillation among patients with known cardiac disease, supporting the hypothesis that meteorologic conditions trigger acute cardiovascular episodes. PMID:25756220

  11. High Response Dew Point Measurement System for a Supersonic Wind Tunnel

    NASA Technical Reports Server (NTRS)

    Blumenthal, Philip Z.

    1996-01-01

    A new high response on-line measurement system has been developed to continuously display and record the air stream dew point in the NASA Lewis 10 x 10 supersonic wind tunnel. Previous instruments suffered from such problems as very slow response, erratic readings, and high susceptibility to contamination. The system operates over the entire pressure level range of the 10 x 10 SWT, from less than 2 psia to 45 psia, without the need for a vacuum pump to provide sample flow. The system speeds up tunnel testing, provides large savings in tunnel power costs and provides the dew point input for the data-reduction subroutines which calculate test section conditions.

  12. Portable Dew Point Mass Spectrometry System for Real-Time Gas and Moisture Analysis

    NASA Technical Reports Server (NTRS)

    Arkin, C.; Gillespie, Stacey; Ratzel, Christopher

    2010-01-01

    A portable instrument incorporates both mass spectrometry and dew point measurement to provide real-time, quantitative gas measurements of helium, nitrogen, oxygen, argon, and carbon dioxide, along with real-time, quantitative moisture analysis. The Portable Dew Point Mass Spectrometry (PDP-MS) system comprises a single quadrupole mass spectrometer and a high vacuum system consisting of a turbopump and a diaphragm-backing pump. A capacitive membrane dew point sensor was placed upstream of the MS, but still within the pressure-flow control pneumatic region. Pressure-flow control was achieved with an upstream precision metering valve, a capacitance diaphragm gauge, and a downstream mass flow controller. User configurable LabVIEW software was developed to provide real-time concentration data for the MS, dew point monitor, and sample delivery system pressure control, pressure and flow monitoring, and recording. The system has been designed to include in situ, NIST-traceable calibration. Certain sample tubing retains sufficient water that even if the sample is dry, the sample tube will desorb water to an amount resulting in moisture concentration errors up to 500 ppm for as long as 10 minutes. It was determined that Bev-A-Line IV was the best sample line to use. As a result of this issue, it is prudent to add a high-level humidity sensor to PDP-MS so such events can be prevented in the future.

  13. Thermodynamic temperature assignment to the point of inflection of the melting curve of high-temperature fixed points.

    PubMed

    Woolliams, E R; Anhalt, K; Ballico, M; Bloembergen, P; Bourson, F; Briaudeau, S; Campos, J; Cox, M G; del Campo, D; Dong, W; Dury, M R; Gavrilov, V; Grigoryeva, I; Hernanz, M L; Jahan, F; Khlevnoy, B; Khromchenko, V; Lowe, D H; Lu, X; Machin, G; Mantilla, J M; Martin, M J; McEvoy, H C; Rougié, B; Sadli, M; Salim, S G R; Sasajima, N; Taubert, D R; Todd, A D W; Van den Bossche, R; van der Ham, E; Wang, T; Whittam, A; Wilthan, B; Woods, D J; Woodward, J T; Yamada, Y; Yamaguchi, Y; Yoon, H W; Yuan, Z

    2016-03-28

    The thermodynamic temperature of the point of inflection of the melting transition of Re-C, Pt-C and Co-C eutectics has been determined to be 2747.84 ± 0.35 K, 2011.43 ± 0.18 K and 1597.39 ± 0.13 K, respectively, and the thermodynamic temperature of the freezing transition of Cu has been determined to be 1357.80 ± 0.08 K, where the ± symbol represents 95% coverage. These results are the best consensus estimates obtained from measurements made using various spectroradiometric primary thermometry techniques by nine different national metrology institutes. The good agreement between the institutes suggests that spectroradiometric thermometry techniques are sufficiently mature (at least in those institutes) to allow the direct realization of thermodynamic temperature above 1234 K (rather than the use of a temperature scale) and that metal-carbon eutectics can be used as high-temperature fixed points for thermodynamic temperature dissemination. The results directly support the developing mise en pratique for the definition of the kelvin to include direct measurement of thermodynamic temperature. © 2016 The Author(s).

  14. A Calibration Facility for Dew Point in Air up to 1 MPa

    NASA Astrophysics Data System (ADS)

    Carroll, P. A.; Bell, S. A.; Stevens, M.

    2015-12-01

    The provision of primary dew-point standards for humidified air and nitrogen at atmospheric pressure is well established, and measurement traceability to these standards provides confidence in a vast number of air humidity measurements. However, hygrometers are used industrially at a wide range of pressures. Both the performance of hygrometers and the properties of humid gases are known to vary with gas pressure. The pressure-dependence of gas non-ideality for air-water mixtures (water-vapor enhancement factor) is well enough known at moderate pressures, but there remains a need to characterize hygrometers at the pressure of use. To address this, a humidity calibration capability of wider scope is under development at the UK National Physical Laboratory (NPL). As an initial stage in the development of this capability, a humidity standard generating air or nitrogen in the dew-point range from -60° C to +10° C, at pressures up to 1 MPa (10 bar) has been validated for the calibration of hygrometers. The expanded uncertainty of the dew-point generator in this range with a coverage factor k= 2 is ± 0.07° C.

  15. Thermodynamic Temperature of High-Temperature Fixed Points Traceable to Blackbody Radiation and Synchrotron Radiation

    NASA Astrophysics Data System (ADS)

    Wähmer, M.; Anhalt, K.; Hollandt, J.; Klein, R.; Taubert, R. D.; Thornagel, R.; Ulm, G.; Gavrilov, V.; Grigoryeva, I.; Khlevnoy, B.; Sapritsky, V.

    2017-10-01

    Absolute spectral radiometry is currently the only established primary thermometric method for the temperature range above 1300 K. Up to now, the ongoing improvements of high-temperature fixed points and their formal implementation into an improved temperature scale with the mise en pratique for the definition of the kelvin, rely solely on single-wavelength absolute radiometry traceable to the cryogenic radiometer. Two alternative primary thermometric methods, yielding comparable or possibly even smaller uncertainties, have been proposed in the literature. They use ratios of irradiances to determine the thermodynamic temperature traceable to blackbody radiation and synchrotron radiation. At PTB, a project has been established in cooperation with VNIIOFI to use, for the first time, all three methods simultaneously for the determination of the phase transition temperatures of high-temperature fixed points. For this, a dedicated four-wavelengths ratio filter radiometer was developed. With all three thermometric methods performed independently and in parallel, we aim to compare the potential and practical limitations of all three methods, disclose possibly undetected systematic effects of each method and thereby confirm or improve the previous measurements traceable to the cryogenic radiometer. This will give further and independent confidence in the thermodynamic temperature determination of the high-temperature fixed point's phase transitions.

  16. The influence of dew point during annealing on the power loss of electrical steel sheets

    NASA Astrophysics Data System (ADS)

    Broddefalk, Arvid; Jenkins, Keith; Silk, Nick; Lindenmo, Magnus

    Decarburization is a necessary part of the processing of electrical steels if their carbon content is above a certain level. The process is usually carried out in a wet hydrogen-nitrogen atmosphere. Having a high dew point has a negative influence on the power loss, though. This is due to oxidation of the steel, which hinders domain wall motion near the surface. In this study, an increase of the power loss was only observed at a fairly high dew point (>20 °C). It was also only at these high dew points where a subsurface oxide layer was observed. The surfaces of samples with and without this layer were etched in steps. The magnetic properties of the etched samples corresponded well with the expected behavior based on GDOES profiles of the samples.

  17. Efficiency and temperature dependence of water removal by membrane dryers

    NASA Technical Reports Server (NTRS)

    Leckrone, K. J.; Hayes, J. M.

    1997-01-01

    The vapor pressure of water in equilibrium with sorption sites within a Nafion membrane is given by log P(WN) = -3580/T + 10.01, where P(WN) is expressed in Torr and T is the membrane temperature, in kelvin. The efficiency of dryers based on selective permeation of water through Nafion can thus be enhanced by cooling the membrane. Residual water in effluents exceeds equilibrium levels if insufficient time is allowed for water to diffuse to the membrane surface as gas passes through the dryer. For tubular configurations, this limitation can be avoided if L > or = Fc(10(3.8)/120 pi D), where L is the length of the tubular membrane, in centimeters, Fc is the gas flow rate, in mL/ min, and D is the diffusion coefficient for water in the carrier gas at the operating temperature of the dryer, in cm2/s. An efficient dryer that at room temperature dries gas to a dew point of -61 degrees C is described; the same dryer maintained at 0 degrees C yields a dew point of -80 degrees C and removes water as effectively as Mg(ClO4)2 or a dry ice/acetone slush. The use of Nafion membranes to construct devices capable of delivering gas streams with low but precisely controlled humidities is discussed.

  18. Temperature and relative humidity distributions in a medium-size administrative town in southwest Nigeria.

    PubMed

    Akinbode, O M; Eludoyin, A O; Fashae, O A

    2008-04-01

    This study was carried out in one of the medium-sized public administrative towns in the southwestern part of Nigeria. Its aim is to highlight the effect of spatial distribution of settlements, population, and socio-economic activities on urban air temperature and humidity in the town. Temperature and relative humidity data from 1992 to 2001 were obtained from three meteorological stations in Akure, the Administrative Capital of Ondo State, Nigeria. The stations are located within the Federal Ministry of Aviation, Akure Airport (FMA), Federal University of Technology, Akure (FUTA) and Federal School of Agriculture (SOA). Air temperature and relative humidity measurements were also obtained from 27 points, which were cited to include road junctions, markets, built up areas, etc., using sling psychrometer. The data were subsequently analysed for spatial and temporal variations using statistical packages (SPSS and Microsoft Excel) and isolines. Actual vapour pressure and dew point temperature were computed using Magnus conversion formulae. The results obtained showed that spatial variation was insignificant, in terms of the temperature and humidity variables. The annual mean temperature (Tmean) ranged between 21.9 and 30.4 degrees C while minimum (Tmin) and maximum (Tmax) temperatures varied from 13 to 26 and 21.5-39.6 degrees C, respectively. Relative humidity (RH), actual vapour pressure (Es) and dew point temperature (Td) values also varied from 39.1% to 98.2%, 19.7-20.8 gm(-3), and 17.3-17.8 degrees C, respectively. A significant relationship (p>0.6; r<0.05) between Tmin, Es and Td was observed while the daytime 'urban heat island' intensity (UHI) ranged between 0.5 and 2.5 degrees C within the study period. The study concluded that there is influence of urban canopy on the microclimate of Akure, and hypothesizes that the urban dwellers may be subjected to some levels of weather related physiological disorderliness.

  19. Data set: 31 years of spatially distributed air temperature, humidity, precipitation amount and precipitation phase from a mountain catchment in the rain-snow transition zone

    USDA-ARS?s Scientific Manuscript database

    Thirty one years of spatially distributed air temperature, relative humidity, dew point temperature, precipitation amount, and precipitation phase data are presented for the Reynolds Creek Experimental Watershed. The data are spatially distributed over a 10m Lidar-derived digital elevation model at ...

  20. Relation of Total and Cardiovascular Death Rates to Climate System, Temperature, Barometric Pressure, and Respiratory Infection.

    PubMed

    Schwartz, Bryan G; Qualls, Clifford; Kloner, Robert A; Laskey, Warren K

    2015-10-15

    A distinct seasonal pattern in total and cardiovascular death rates has been reported. The factors contributing to this pattern have not been fully explored. Seven locations (average total population 71,354,000) were selected where data were available including relatively warm, cold, and moderate temperatures. Over the period 2004 to 2009, there were 2,526,123 all-cause deaths, 838,264 circulatory deaths, 255,273 coronary heart disease deaths, and 135,801 ST-elevation myocardial infarction (STEMI) deaths. We used time series and multivariate regression modeling to explore the association between death rates and climatic factors (temperature, dew point, precipitation, barometric pressure), influenza levels, air pollution levels, hours of daylight, and day of week. Average seasonal patterns for all-cause and cardiovascular deaths were very similar across the 7 locations despite differences in climate. After adjusting for multiple covariates and potential confounders, there was a 0.49% increase in all-cause death rate for every 1°C decrease. In general, all-cause, circulatory, coronary heart disease and STEMI death rates increased linearly with decreasing temperatures. The temperature effect varied by location, including temperature's linear slope, cubic fit, positional shift on the temperature axis, and the presence of circulatory death increases in locally hot temperatures. The variable effect of temperature by location suggests that people acclimatize to local temperature cycles. All-cause and circulatory death rates also demonstrated sizable associations with influenza levels, dew point temperature, and barometric pressure. A greater understanding of how climate, temperature, and barometric pressure influence cardiovascular responses would enhance our understanding of circulatory and STEMI deaths. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Use of dew-point hygrometry, direct sweat collection, and measurement of body water losses to determine sweating rates in exercising horses.

    PubMed

    Kingston, J K; Geor, R J; McCutcheon, L J

    1997-02-01

    To compare dew-point hygrometry, direct sweat collection, and measurement of body water loss as methods for determination of sweating rate (SR) in exercising horses. 6 exercise-trained Thoroughbreds. SR was measured in 6 horses exercising at 40% of the speed that elicited maximum oxygen consumption for 45 km, with a 15-minute rest at the end of each 15-km phase. Each horse completed 2 exercise trials. Dew-point hygrometry, as a method of local SR determination, was validated in vitro by measurement of rate of evaporative water loss. During exercise, local SR was determined every 10 minutes by the following 2 methods: (1) dew-point hygrometry on the neck and lateral area of the thorax, and (2) on the basis of the volume of sweat collected from a sealed plastic pouch attached to the lateral area of the thorax. Mean whole body SR was calculated from total body water loss incurred during exercise. Evaporation rate measured by use of dew-point hygrometry was significantly correlated (r2 = 0.92) with the actual rate of evaporative water loss. There was a similar pattern of change in SR measured by dew-point hygrometry on the neck and lateral area of the thorax during exercise, with a significantly higher SR on the neck. The SR measured on the thorax by direct sweat collection and by dew-point hygrometry were of similar magnitude. Mean whole body SR calculated from total body water loss was not significantly different from mean whole body SR estimated from direct sweat collection or dew-point hygrometry measurements on the thorax. Dew-point hygrometry and direct sweat collection are useful methods for determination of local SR in horses during prolonged, steady-state exercise in moderate ambient conditions. Both methods of local SR determination provide an accurate estimated of whole body SR.

  2. Sensitive skin at menopause; dew point and electrometric properties of the stratum corneum.

    PubMed

    Paquet, F; Piérard-Franchimont, C; Fumal, I; Goffin, V; Paye, M; Piérard, G E

    1998-01-12

    A number of menopausal women experience skin sensitive to various environmental threats. Two panels of 15 menopausal women on or without HRT were compared. We studied the response of their stratum corneum to variations in environmental humidity, either in air or in response to an emollient. Environment dew point and electrometric measurements on the skin were recorded to search for correlations. Data show that the baseline stratum corneum hydration is influenced by the dew point. HRT improves the barrier function of the skin. The use of emollient further extends the improvement in the functional properties of skin in menopausal women. Both HRT and an emollient can counteract in part some of the deleterious effects of cold and dry weather.

  3. Comparison between the liquidus temperature and triple-point temperature of tin realized by heat pulse-based melting

    NASA Astrophysics Data System (ADS)

    Joung, Wukchul; Pearce, Jonathan V.; Park, Jihye

    2018-06-01

    In this work, the consistency of the heat pulse-based melting technique, which was used to determine the liquidus temperature of tin, was examined by comparing the liquidus temperatures of tin at 101 325 Pa and at the vapour pressure of tin (i.e. the triple-point temperature), both of which were realized by heat pulse-based melting. Periodic square wave-type temperature steps with an amplitude of 0.7 °C were generated in the isothermal region of the pressure-controlled loop heat pipe, and the tin sample, having a segregated impurity distribution established by the prior outward slow freezing, was melted by application of the temperature step-based heat pulses. The triple-point temperature was found to be lower than the liquidus temperature of tin at 101 325 Pa by 3.23 mK with an expanded measurement uncertainty of 0.24 mK (i.e. a coverage factor of k  =  2), while the ideal temperature difference calculated from the ITS-90 given pressure coefficient (i.e. 3.3  ×  10‑8 K Pa‑1) is about 3.34 mK. The difference between the measured temperature difference and ideal temperature difference was attributed to the incomplete removal of the gases in the tin triple-point cell. Overall, these results further corroborated the notion that the heat pulse-based melting technique was shown to yield results consistent with the prescription of the ITS-90, and to be a reliable method in terms of the realization of the fixed-point temperatures.

  4. Daily indoor-to-outdoor temperature and humidity relationships: a sample across seasons and diverse climatic regions

    PubMed Central

    Nguyen, Jennifer L.; Dockery, Douglas W.

    2015-01-01

    The health consequences of heat and cold are usually evaluated based on associations with outdoor measurements at the nearest weather reporting station. However, people in the developed world spend little time outdoors, especially during extreme temperature events. We examined the association between indoor and outdoor temperature and humidity in a range of climates. We measured indoor temperature, apparent temperature, relative humidity, dew point, and specific humidity (a measure of moisture content in air) for one calendar year (2012) in a convenience sample of eight diverse locations ranging from the equatorial region (10°N) to the Arctic (64°N). We then compared the indoor conditions to outdoor values recorded at the nearest airport weather station. We found that the shape of the indoor-to-outdoor temperature and humidity relationships varied across seasons and locations. Indoor temperatures showed little variation across season and location. There was large variation in indoor relative humidity between seasons and between locations which was independent of outdoor, airport measurements. On the other hand, indoor specific humidity, and to a lesser extent dew point, tracked with outdoor, airport measurements both seasonally and between climates, across a wide range of outdoor temperatures. Our results suggest that, depending on the measure, season, and location, outdoor weather measurements can be reliably used to represent indoor exposures and that, in general, outdoor measures of actual moisture content in air better capture indoor exposure than temperature and relative humidity. Therefore, absolute measures of water vapor should be examined in conjunction with other measures (e.g. temperature, relative humidity) in studies of the effect of weather and climate on human health. PMID:26054827

  5. Development of a new densimeter for the combined investigation of dew-point densities and sorption phenomena of fluid mixtures

    NASA Astrophysics Data System (ADS)

    Moritz, Katharina; Kleinrahm, Reiner; McLinden, Mark O.; Richter, Markus

    2017-12-01

    For the determination of dew-point densities and pressures of fluid mixtures, a new densimeter has been developed. The new apparatus is based on the well-established two-sinker density measurement principle with the additional capability of quantifying sorption effects. In the vicinity of the dew line, such effects cause a change in composition of the gas mixture under study, which can significantly distort accurate density measurements. The new experimental technique enables the accurate measurement of dew-point densities and pressures and the quantification of sorption effects at the same time.

  6. Investigation of Changes in Extreme Temperature and Humidity Over China Through a Dynamical Downscaling Approach

    NASA Astrophysics Data System (ADS)

    Zhu, Jinxin; Huang, Gordon; Wang, Xiuquan; Cheng, Guanhui

    2017-11-01

    Impacts of climate change relating to public health are often determined by multiple climate variables. The health-related metrics combining high-temperature and relative humidity are most concerned. Temperatures, relative humidity and relationship among them are investigated here for a comprehensive assessment of climate change impacts over China. A projection of combined temperatures and humidity through the PRECIS model is addressed. The PRECIS model's skill in reproducing the historical climate over China was first gauged through validating its historical simulation with the observation data set in terms of the two contributing variables. With good results of validation, a plausible range of combined temperatures and relative humidity were generated under RCPs. The results suggested that the annual mean temperature of China will increase up to 6°C at the end of 21st century. Opposite to the significantly change in the temperature, the maximum magnitude of changes in relative humidity is only 8% from the value in the baseline period. The dew point temperature is projected to be 14.9°C (within the comfortable interval) over the whole nation under high radiative forcing scenario at the end of this century. Therefore, the combination effects of high temperatures and relative humidity are substantially smaller than generally anticipated for China. Even though the impact-relevant metric like the dew point temperature is not projected as bad as the generally anticipated, we found that the frequency of high-temperature extremes increases up to 40% and the duration increases up to 150% in China. China is still expected to have more number of extremely hot days, more frequent high-temperature extremes, and longer duration of warm spell than before. Regionally, South China has the smallest changes in the mean, maximum and minimum temperatures while the largest increases in all five high-temperature indices. Consequently, the climate over South China for two future

  7. Estimating monthly temperature using point based interpolation techniques

    NASA Astrophysics Data System (ADS)

    Saaban, Azizan; Mah Hashim, Noridayu; Murat, Rusdi Indra Zuhdi

    2013-04-01

    This paper discusses the use of point based interpolation to estimate the value of temperature at an unallocated meteorology stations in Peninsular Malaysia using data of year 2010 collected from the Malaysian Meteorology Department. Two point based interpolation methods which are Inverse Distance Weighted (IDW) and Radial Basis Function (RBF) are considered. The accuracy of the methods is evaluated using Root Mean Square Error (RMSE). The results show that RBF with thin plate spline model is suitable to be used as temperature estimator for the months of January and December, while RBF with multiquadric model is suitable to estimate the temperature for the rest of the months.

  8. Analysis of the Dryden Wet Bulb GLobe Temperature Algorithm for White Sands Missile Range

    NASA Technical Reports Server (NTRS)

    LaQuay, Ryan Matthew

    2011-01-01

    In locations where workforce is exposed to high relative humidity and light winds, heat stress is a significant concern. Such is the case at the White Sands Missile Range in New Mexico. Heat stress is depicted by the wet bulb globe temperature, which is the official measurement used by the American Conference of Governmental Industrial Hygienists. The wet bulb globe temperature is measured by an instrument which was designed to be portable and needing routine maintenance. As an alternative form for measuring the wet bulb globe temperature, algorithms have been created to calculate the wet bulb globe temperature from basic meteorological observations. The algorithms are location dependent; therefore a specific algorithm is usually not suitable for multiple locations. Due to climatology similarities, the algorithm developed for use at the Dryden Flight Research Center was applied to data from the White Sands Missile Range. A study was performed that compared a wet bulb globe instrument to data from two Surface Atmospheric Measurement Systems that was applied to the Dryden wet bulb globe temperature algorithm. The period of study was from June to September of2009, with focus being applied from 0900 to 1800, local time. Analysis showed that the algorithm worked well, with a few exceptions. The algorithm becomes less accurate to the measurement when the dew point temperature is over 10 Celsius. Cloud cover also has a significant effect on the measured wet bulb globe temperature. The algorithm does not show red and black heat stress flags well due to shorter time scales of such events. The results of this study show that it is plausible that the Dryden Flight Research wet bulb globe temperature algorithm is compatible with the White Sands Missile Range, except for when there are increased dew point temperatures and cloud cover or precipitation. During such occasions, the wet bulb globe temperature instrument would be the preferred method of measurement. Out of the 30

  9. Stochastic investigation of temperature process for climatic variability identification

    NASA Astrophysics Data System (ADS)

    Lerias, Eleutherios; Kalamioti, Anna; Dimitriadis, Panayiotis; Markonis, Yannis; Iliopoulou, Theano; Koutsoyiannis, Demetris

    2016-04-01

    The temperature process is considered as the most characteristic hydrometeorological process and has been thoroughly examined in the climate-change framework. We use a dataset comprising hourly temperature and dew point records to identify statistical variability with emphasis on the last period. Specifically, we investigate the occurrence of mean, maximum and minimum values and we estimate statistical properties such as marginal probability distribution function and the type of decay of the climacogram (i.e., mean process variance vs. scale) for various time periods. Acknowledgement: This research is conducted within the frame of the undergraduate course "Stochastic Methods in Water Resources" of the National Technical University of Athens (NTUA). The School of Civil Engineering of NTUA provided moral support for the participation of the students in the Assembly.

  10. Will the warmer temperature bring the more intensity precipitation?

    NASA Astrophysics Data System (ADS)

    Yutong, Z., II; Wang, T.

    2017-12-01

    Will the warmer temperature bring the more intensity precipitation?Over the past several decades, changes in climate are amplified over the Tibetan Plateau(TP), with warming trend almost being twice as large as the global average. In sharp contrast, there is a large spatial discrepancy of the variations in precipitation extremes, with increasing trends found in the southern and decreasing trends in central TP. These features motivate are urgent need for an observation-based understanding of how precipitation extremes respond to climate change. Here we examine the relation between precipitation intensity with atmospheric temperature, dew point temperature (Td) and convective available potential energy (CAPE) in Tibet Plateau. Owing to the influences of the westerlies and Indian monsoon on Tibetan climate, the stations can be divided into three sub-regions in TP: the westerlies region (north of 35°N, N = 28), the monsoon region (south of 30°N in TP, N = 31), and the transition region (located between 30°N and 35°N, N = 48). We found that the intensity precipitation does not follow the C-C relation and there is a mix of positive and negative slope. To better understand why different scaling occurs with temperature in district region, using the dew point temperature replace the temperature, although there is significant variability in relative humidity values, at most stations, there appears to be a general increase in relative humidity associated. It is likely that the observed rise in relative humidity can assist in explaining the negative scaling of extreme precipitation at westerlies domain and monsoon domain, with the primary reason why precipitation extremes expected to increase follows from the fact that a warmer atmosphere can "hold" more moisture. This suggests that not only on how much the moisture the atmosphere can hold, but on how much moisture exits in atmosphere. To understand the role of dynamic on extreme precipitation, we repeat the precipitation

  11. Selective oxidation of dual phase steel after annealing at different dew points

    NASA Astrophysics Data System (ADS)

    Lins, Vanessa de Freitas Cunha; Madeira, Laureanny; Vilela, Jose Mario Carneiro; Andrade, Margareth Spangler; Buono, Vicente Tadeu Lopes; Guimarães, Juliana Porto; Alvarenga, Evandro de Azevedo

    2011-04-01

    Hot galvanized steels have been extensively used in the automotive industry. Selective oxidation on the steel surface affects the wettability of zinc on steel and the grain orientation of inhibition layer (Fe-Al-Zn alloy) and reduces the iron diffusion to the zinc layer. The aim of this work is to identify and quantify selective oxidation on the surface of a dual phase steel, and an experimental steel with a lower content of manganese, annealed at different dew points. The techniques employed were atomic force microscopy, X-ray photoelectron spectroscopy, and glow discharge optical emission spectroscopy. External selective oxidation was observed for phosphorus on steel surface annealed at 0 °C dp, and for manganese, silicon, and aluminum at a lower dew point. The concentration of manganese was higher on the dual phase steel surface than on the surface of the experimental steel. The concentration of molybdenum on the surface of both steels increased as the depth increased.

  12. Thermodynamic Temperature Measurement to the Indium Point Based on Radiance Comparison

    NASA Astrophysics Data System (ADS)

    Yamaguchi, Y.; Yamada, Y.

    2017-04-01

    A multi-national project (the EMRP InK project) was completed recently, which successfully determined the thermodynamic temperatures of several of the high-temperature fixed points above the copper point. The National Metrology Institute of Japan contributed to this project with its newly established absolute spectral radiance calibration capability. In the current study, we have extended the range of thermodynamic temperature measurement to below the copper point and measured the thermodynamic temperatures of the indium point (T_{90} = 429.748 5 K), tin point (505.078 K), zinc point (692.677 K), aluminum point (933.473 K) and the silver point (1 234.93 K) by radiance comparison against the copper point, with a set of radiation thermometers having center wavelengths ranging from 0.65 μm to 1.6 μm. The copper-point temperature was measured by the absolute radiation thermometer which was calibrated by radiance method traceable to the electrical substitution cryogenic radiometer. The radiance of the fixed-point blackbodies was measured by standard radiation thermometers whose spectral responsivity and nonlinearity are precisely evaluated, and then the thermodynamic temperatures were determined from radiance ratios to the copper point. The values of T-T_{90} for the silver-, aluminum-, zinc-, tin- and indium-point cells were determined as -4 mK (U = 104 mK, k=2), -99 mK (88 mK), -76 mK (76 mK), -68 mK (163 mK) and -42 mK (279 mK), respectively.

  13. The gallium melting-point standard: its role in our temperature measurement system.

    PubMed

    Mangum, B W

    1977-01-01

    The latest internationally-adopted temperature scale, the International Practical Temperature Scale of 1968 (amended edition of 1975), is discussed in some detail and a brief description is given of its evolution. The melting point of high-purity gallium (stated to be at least 99.99999% pure) as a secondary temperature reference point is evaluated. I believe that this melting-point temperature of gallium should be adopted by the various medical professional societies and voluntary standards groups as the reaction temperature for enzyme reference methods in clinical enzymology. Gallium melting-point cells are available at the National Bureau of Standards as Standard Reference Material No. 1968.

  14. Removal mechanisms of dew via self-propulsion off the gecko skin

    PubMed Central

    Watson, Gregory S.; Schwarzkopf, Lin; Cribb, Bronwen W.; Myhra, Sverre; Gellender, Marty; Watson, Jolanta A.

    2015-01-01

    Condensation resulting in the formation of water films or droplets is an unavoidable process on the cuticle or skin of many organisms. This process generally occurs under humid conditions when the temperature drops below the dew point. In this study, we have investigated dew conditions on the skin of the gecko Lucasium steindachneri. When condensation occurs, we show that small dew drops, as opposed to a thin film, form on the lizard's scales. As the droplets grow in size and merge, they can undergo self-propulsion off the skin and in the process can be carried away a sufficient distance to freely engage with external forces. We show that factors such as gravity, wind and fog provide mechanisms to remove these small droplets off the gecko skin surface. The formation of small droplets and subsequent removal from the skin may aid in reducing microbial contact (e.g. bacteria, fungi) and limit conducive growth conditions under humid environments. As well as providing an inhospitable microclimate for microorganisms, the formation and removal of small droplets may also potentially aid in other areas such as reduction and cleaning of some surface contaminants consisting of single or multiple aggregates of particles. PMID:25762647

  15. Automated system for measuring temperature profiles inside ITS-90 fixed-point cells

    NASA Astrophysics Data System (ADS)

    Hiti, Miha; Bojkovski, Jovan; Batagelj, Valentin; Drnovsek, Janko

    2005-11-01

    The defining fixed points of the International Temperature Scale of 1990 (ITS-90) are temperature reference points for temperature calibration. The measured temperature inside the fixed-point cell depends on thermometer immersion, since measurements are made below the surface of the fixed-point material and the additional effect of the hydrostatic pressure has to be taken into account. Also, the heat flux along the thermometer stem can affect the measured temperature. The paper presents a system that enables accurate and reproducible immersion profile measurements for evaluation of measurement sensitivity and adequacy of thermometer immersion. It makes immersion profile measurements possible, where a great number of repetitions and long measurement periods are required, and reduces the workload on the user for performing such measurements. The system is flexible and portable and was developed for application to existing equipment in the laboratory. Results of immersion profile measurements in a triple point of water fixed-point cell are presented.

  16. Investigation of the stochastic nature of temperature and humidity for energy management

    NASA Astrophysics Data System (ADS)

    Hadjimitsis, Evanthis; Demetriou, Evangelos; Sakellari, Katerina; Tyralis, Hristos; Iliopoulou, Theano; Koutsoyiannis, Demetris

    2017-04-01

    Atmospheric temperature and dew point, in addition to their role in atmospheric processes, influence the management of energy systems since they highly affect the energy demand and production. Both temperature and humidity depend on the climate conditions and geographical location. In this context, we analyze numerous of observations around the globe and we investigate the long-term behaviour and periodicities of the temperature and humidity processes. Also, we present and apply a parsimonious stochastic double-cyclostationary model for these processes to an island in the Aegean Sea and investigate their link to energy management. Acknowledgement: This research is conducted within the frame of the undergraduate course "Stochastic Methods in Water Resources" of the National Technical University of Athens (NTUA). The School of Civil Engineering of NTUA provided moral support for the participation of the students in the Assembly.

  17. Reliability of High-Temperature Fixed-Point Installations over 8 Years

    NASA Astrophysics Data System (ADS)

    Elliott, C. J.; Ford, T.; Ongrai, O.; Pearce, J. V.

    2017-12-01

    At NPL, high-temperature metal-carbon eutectic fixed points have been set up for thermocouple calibration purposes since 2006, for realising reference temperatures above the highest point specified in the International Temperature Scale of 1990 for contact thermometer calibrations. Additionally, cells of the same design have been provided by NPL to other national measurement institutes (NMIs) and calibration laboratories over this period, creating traceable and ISO 17025 accredited facilities around the world for calibrating noble metal thermocouples at 1324 {°}C (Co-C) and 1492 {°}C (Pd-C). This paper shows collections of thermocouple calibration results obtained during use of the high-temperature fixed-point cells at NPL and, as further examples, the use of cells installed at CCPI Europe (UK) and NIMT (Thailand). The lifetime of the cells can now be shown to be in excess of 7 years, whether used on a weekly or monthly basis, and whether used in an NMI or industrial calibration laboratory.

  18. Multiple-Point Temperature Gradient Algorithm for Ring Laser Gyroscope Bias Compensation

    PubMed Central

    Li, Geng; Zhang, Pengfei; Wei, Guo; Xie, Yuanping; Yu, Xudong; Long, Xingwu

    2015-01-01

    To further improve ring laser gyroscope (RLG) bias stability, a multiple-point temperature gradient algorithm is proposed for RLG bias compensation in this paper. Based on the multiple-point temperature measurement system, a complete thermo-image of the RLG block is developed. Combined with the multiple-point temperature gradients between different points of the RLG block, the particle swarm optimization algorithm is used to tune the support vector machine (SVM) parameters, and an optimized design for selecting the thermometer locations is also discussed. The experimental results validate the superiority of the introduced method and enhance the precision and generalizability in the RLG bias compensation model. PMID:26633401

  19. Inventory of File nam.t00z.smartpr12.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific 11 hour fcst Temperature [K] 032 surface TMP 10 hour fcst Temperature [K] 033 surface DPT 11 hour fcst Dew Point Temperature [K] 034 surface DPT 10 hour fcst Dew Point Temperature [K] 035 surface TMAX

  20. Inventory of File nam.t00z.smartak12.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific 11 hour fcst Temperature [K] 032 surface TMP 10 hour fcst Temperature [K] 033 surface DPT 11 hour fcst Dew Point Temperature [K] 034 surface DPT 10 hour fcst Dew Point Temperature [K] 035 surface TMAX

  1. Inventory of File nam.t00z.smarthi12.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific 11 hour fcst Temperature [K] 032 surface TMP 10 hour fcst Temperature [K] 033 surface DPT 11 hour fcst Dew Point Temperature [K] 034 surface DPT 10 hour fcst Dew Point Temperature [K] 035 surface TMAX

  2. Retrieving air humidity, global solar radiation, and reference evapotranspiration from daily temperatures: development and validation of new methods for Mexico. Part I: humidity

    NASA Astrophysics Data System (ADS)

    Lobit, P.; López Pérez, L.; Lhomme, J. P.; Gómez Tagle, A.

    2017-07-01

    This study evaluates the dew point method (Allen et al. 1998) to estimate atmospheric vapor pressure from minimum temperature, and proposes an improved model to estimate it from maximum and minimum temperature. Both methods were evaluated on 786 weather stations in Mexico. The dew point method induced positive bias in dry areas but also negative bias in coastal areas, and its average root mean square error for all evaluated stations was 0.38 kPa. The improved model assumed a bi-linear relation between estimated vapor pressure deficit (difference between saturated vapor pressure at minimum and average temperature) and measured vapor pressure deficit. The parameters of these relations were estimated from historical annual median values of relative humidity. This model removed bias and allowed for a root mean square error of 0.31 kPa. When no historical measurements of relative humidity were available, empirical relations were proposed to estimate it from latitude and altitude, with only a slight degradation on the model accuracy (RMSE = 0.33 kPa, bias = -0.07 kPa). The applicability of the method to other environments is discussed.

  3. Inventory of File nam.t00z.smartconus03.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 3 hour fcst Dew Point Temperature [K] 003 surface SPFH 3 hour fcst Specific Temperature [K] 026 surface TMP 1 hour fcst Temperature [K] 027 surface DPT 2 hour fcst Dew Point Temperature [K] 028 surface DPT 1 hour fcst Dew Point Temperature [K] 029 surface TMAX 0-3 hour acc Maximum

  4. Inventory of File gfs.t06z.smartguam18.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 18 hour fcst Dew Point Temperature [K] 003 surface SPFH 18 hour fcst Specific TMP 17 hour fcst Temperature [K] 022 surface TMP 16 hour fcst Temperature [K] 023 surface DPT 17 hour fcst Dew Point Temperature [K] 024 surface DPT 16 hour fcst Dew Point Temperature [K] 025 surface TMAX

  5. High-temperature phase relations and thermodynamics in the iron-lead-sulfur system

    NASA Astrophysics Data System (ADS)

    Eric, R. Hurman; Ozok, Hakan

    1994-01-01

    The PbS activities in FeS-PbS liquid mattes were obtained at 1100 °C and 1200 °C by the dew-point method. Negative deviations were observed, and the liquid-matte solutions were modeled by the Krupkowski formalism. The liquid boundaries of the FeS-PbS phase diagram were derived from the model equations yielding a eutectic temperature of 842 °C at X Pbs = 0.46. A phase diagram of the pseudobinary FeS-PbS was also verified experimentally by quenching samples equilibrated in evacuated and sealed silica capsules. No terminal solid solution ranges could be found. Within the Fe-Pb-S ternary system, the boundaries of the immiscibility region together with the tie-line distributions were established at 1200 °C. Activities of Pb were measured by the dew-point technique along the metal-rich boundary of the miscibility gap. Activities of Fe, Pb, and S, along the miscibility gap were also calculated by utilizing the bounding binary thermodynamics, phase equilibria, and tie-lines.

  6. The succinonitrile triple-point standard: a fixed point to improve the accuracy of temperature measurements in the clinical laboratory.

    PubMed

    Mangum, B W

    1983-07-01

    In an investigation of the melting and freezing behavior of succinonitrile, the triple-point temperature was determined to be 58.0805 degrees C, with an estimated uncertainty of +/- 0.0015 degrees C relative to the International Practical Temperature Scale of 1968 (IPTS-68). The triple-point temperature of this material is evaluated as a temperature-fixed point, and some clinical laboratory applications of this fixed point are proposed. In conjunction with the gallium and ice points, the availability of succinonitrile permits thermistor thermometers to be calibrated accurately and easily on the IPTS-68.

  7. Reproducibility of WC-C High-Temperature Fixed Point

    NASA Astrophysics Data System (ADS)

    Grigoryeva, I. A.; Khlevnoy, B. B.; Solodilov, M. V.

    2017-05-01

    Reproducibility of the tungsten carbide-carbon peritectic (WC-C) fixed point (3021 K) was investigated by comparing six WC-C blackbody-type cells with each other. All the cells were built at VNIIOFI and had the same design with a cell outer diameter of 24 mm and a cavity opening diameter of 3 mm. Four cells were built using tungsten powder supplied by Alfa Aesar, while the other two cells used powder from Zhuzhou KETE (China). The nominal purity of both suppliers was 99.999 %. All the cells were compared in the same furnace. A reference cell in the second furnace was used for monitoring the stability of a radiation thermometer. Melting temperatures (given by the point of inflection) of all six cells agreed within ±45 mK. The reproducibility, as a standard deviation of the measured temperatures, can be estimated as 35 mK. The Zhuzhou KETE cells showed a slightly lower temperature than the Alfa Aesar cells: by 32 mK on average, which is comparable with repeatability of the measurements.

  8. Removal mechanisms of dew via self-propulsion off the gecko skin.

    PubMed

    Watson, Gregory S; Schwarzkopf, Lin; Cribb, Bronwen W; Myhra, Sverre; Gellender, Marty; Watson, Jolanta A

    2015-04-06

    Condensation resulting in the formation of water films or droplets is an unavoidable process on the cuticle or skin of many organisms. This process generally occurs under humid conditions when the temperature drops below the dew point. In this study, we have investigated dew conditions on the skin of the gecko Lucasium steindachneri. When condensation occurs, we show that small dew drops, as opposed to a thin film, form on the lizard's scales. As the droplets grow in size and merge, they can undergo self-propulsion off the skin and in the process can be carried away a sufficient distance to freely engage with external forces. We show that factors such as gravity, wind and fog provide mechanisms to remove these small droplets off the gecko skin surface. The formation of small droplets and subsequent removal from the skin may aid in reducing microbial contact (e.g. bacteria, fungi) and limit conducive growth conditions under humid environments. As well as providing an inhospitable microclimate for microorganisms, the formation and removal of small droplets may also potentially aid in other areas such as reduction and cleaning of some surface contaminants consisting of single or multiple aggregates of particles. © 2015 The Author(s) Published by the Royal Society. All rights reserved.

  9. Inventory of File nam.t00z.smartak06.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 6 hour fcst Dew Point Temperature [K] 003 surface SPFH 6 hour fcst Specific Haines Index [Numeric] 029 surface TMP 5 hour fcst Temperature [K] 030 surface TMP 4 hour fcst Temperature [K] 031 surface DPT 5 hour fcst Dew Point Temperature [K] 032 surface DPT 4 hour fcst Dew Point

  10. Inventory of File nam.t00z.smartak03.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 3 hour fcst Dew Point Temperature [K] 003 surface SPFH 3 hour fcst Specific fcst Haines Index [Numeric] 026 surface TMP 2 hour fcst Temperature [K] 027 surface TMP 1 hour fcst Temperature [K] 028 surface DPT 2 hour fcst Dew Point Temperature [K] 029 surface DPT 1 hour fcst Dew Point

  11. Evaluation of a 2.5 kWel automotive low temperature PEM fuel cell stack with extended operating temperature range up to 120 °C

    NASA Astrophysics Data System (ADS)

    Ruiu, Tiziana; Dreizler, Andreas M.; Mitzel, Jens; Gülzow, Erich

    2016-01-01

    Nowadays, the operating temperature of polymer electrolyte membrane fuel cell stacks is typically limited to 80 °C due to water management issues of membrane materials. In the present work, short-term operation at elevated temperatures up to 120 °C and long-term steady-state operation under automotive relevant conditions at 80 °C are examined using a 30-cell stack developed at DLR. The high temperature behavior is investigated by using temperature cycles between 90 and 120 °C without adjustment of the gases dew points, to simulate a short-period temperature increase, possibly caused by an extended power demand and/or limited heat removal. This galvanostatic test demonstrates a fully reversible performance decrease of 21 ± 1% during each thermal cycle. The irreversible degradation rate is about a factor of 6 higher compared to the one determined by the long-term test. The 1200-h test at 80 °C demonstrates linear stack voltage decay with acceptable degradation rate, apart from a malfunction of the air compressor, which results in increased catalyst degradation effects on individual cells. This interpretation is based on an end-of-life characterization, aimed to investigate catalyst, electrode and membrane degradation, by determining hydrogen crossover rates, high frequency resistances, electrochemically active surface areas and catalyst particle sizes.

  12. Method of and apparatus for determining deposition-point temperature

    DOEpatents

    Mansure, Arthur J.; Spates, James J.; Martin, Stephen J.

    1998-01-01

    Acoustic-wave sensor apparatus and method for analyzing a normally liquid petroleum-based composition for monitoring deposition-point temperature. The apparatus includes at least one acoustic-wave device such as SAW, QCM, FPM, TSM or APM type devices in contact with the petroleum-based composition for sensing or detecting the surface temperature at which deposition occurs and/or rate of deposition as a function of temperature by sensing an accompanying change in frequency, phase shift, damping voltage or damping current of an electrical oscillator to a known calibrated condition. The acoustic wave device is actively cooled to monitor the deposition of constituents such as paraffins by determining the point at which solids from the liquid composition begin to form on the acoustic wave device. The acoustic wave device can be heated to melt or boil off the deposits to reset the monitor and the process can be repeated.

  13. High performance miniature hygrometer and method thereof

    NASA Technical Reports Server (NTRS)

    VanZandt, Thomas R. (Inventor); Kaiser, William J. (Inventor); Kenny, Thomas W. (Inventor); Crisp, David (Inventor)

    1994-01-01

    An uncoated interdigitated transducer is cooled from a temperature above the dew point to a temperature below the dew point, while a parameter of a signal of the transducer is measured. The reduction in temperature causes a monotonic change in transducer signal because that signal is sensitive primarily to the water loading of the transducer surface as water forms on that surface due to the reduction in temperature. As the dew point is approached with temperature reduction, the slope of the curve of transducer signal with respect to temperature, remains relatively constant. However, as the dew point is reached the slope of that curve increases and because of changes in the structure of the water layer on the surface of the transducer, at the dew point the transducer responds with a clear shift in the rate at which the transducer signal changes. The temperature at which the second derivative of signal vs. temperature peaks can be readily used to identify with extreme accuracy, the precise dew point. The measurement technique employed by the present invention is relatively immune to surface contamination which remains significantly unchanged during the brief measurement period.

  14. Optimization of the thermogauge furnace for realizing high temperature fixed points

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, T.; Dong, W.; Liu, F.

    2013-09-11

    The thermogauge furnace was commonly used in many NMIs as a blackbody source for calibration of the radiation thermometer. It can also be used for realizing the high temperature fixed point(HTFP). According to our experience, when realizing HTFP we need the furnace provide relative good temperature uniformity to avoid the possible damage to the HTFP. To improve temperature uniformity in the furnace, the furnace tube was machined near the tube ends with a help of a simulation analysis by 'ansys workbench'. Temperature distributions before and after optimization were measured and compared at 1300 °C, 1700°C, 2500 °C, which roughly correspondmore » to Co-C(1324 °C), Pt-C(1738 °C) and Re-C(2474 °C), respectively. The results clearly indicate that through machining the tube the temperature uniformity of the Thermogage furnace can be remarkably improved. A Pt-C high temperature fixed point was realized in the modified Thermogauge furnace subsequently, the plateaus were compared with what obtained using old heater, and the results were presented in this paper.« less

  15. Method of and apparatus for determining deposition-point temperature

    DOEpatents

    Mansure, A.J.; Spates, J.J.; Martin, S.J.

    1998-10-27

    Acoustic-wave sensor apparatus and method are disclosed for analyzing a normally liquid petroleum-based composition for monitoring deposition-point temperature. The apparatus includes at least one acoustic-wave device such as SAW, QCM, FPM, TSM or APM type devices in contact with the petroleum-based composition for sensing or detecting the surface temperature at which deposition occurs and/or rate of deposition as a function of temperature by sensing an accompanying change in frequency, phase shift, damping voltage or damping current of an electrical oscillator to a known calibrated condition. The acoustic wave device is actively cooled to monitor the deposition of constituents such as paraffins by determining the point at which solids from the liquid composition begin to form on the acoustic wave device. The acoustic wave device can be heated to melt or boil off the deposits to reset the monitor and the process can be repeated. 5 figs.

  16. Indirect Determination of the Thermodynamic Temperature of a Gold Fixed-Point Cell

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Girard, F.; Florio, M.

    2010-09-01

    Since the value T 90(Au) was fixed on the ITS-90, some determinations of the thermodynamic temperature of the gold point have been performed which form, with other renormalized results of previous measurements by radiation thermometry, the basis for the current best estimates of ( T - T 90)Au = 39.9 mK as elaborated by the CCT-WG4. Such a value, even if consistent with the behavior of T - T 90 differences at lower temperatures, is quite influenced by the low values of T Au as determined with few radiometric measurements. At INRIM, an independent indirect determination of the thermodynamic temperature of gold was performed by means of a radiation thermometry approach. A fixed-point technique was used to realize approximated thermodynamic scales from the Zn point up to the Cu point. A Si-based standard radiation thermometer working at 900 nm and 950 nm was used. The low uncertainty presently associated to the thermodynamic temperature of fixed points and the accuracy of INRIM realizations, allowed scales with an uncertainty lower than 0.03 K in terms of the thermodynamic temperature to be realized. A fixed-point cell filled with gold, 99.999 % in purity, was measured, and its freezing temperature was determined by both interpolation and extrapolation. An average T Au = 1337.395 K was found with a combined standard uncertainty of 23 mK. Such a value is 25 mK higher than the presently available value as derived by the CCT-WG4 value of ( T - T 90)Au = 39.9 mK.

  17. Synthesis copolymer use to reduce pour point temperature of diamond crude oil

    NASA Astrophysics Data System (ADS)

    Than, Dao Viet; Chuong, Thai Hong; Tuy, Dao Quoc

    2017-09-01

    Diamond oil field is located in Block 01&02 Offshore Vietnam. Crude oil from Diamond Well Head Platform (WHP) is evacuated to FPSO via 20km 10" subsea flexible pipeline. The lowest seabed temperature in the field is 22°C, while the pour point temperature (PPT) of Diamond crude oil is very high (36°C) due to high paraffin content (25%). So studying to research a suitable Pour Point Depressant (PPD) for the crude oil is very important. The PPD must have ability to reduce pour point temperature of crude oil from 36°C to 21°C.

  18. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    PubMed Central

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-01-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions. PMID:25199907

  19. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye

    NASA Astrophysics Data System (ADS)

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-01

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  20. Dew inspired breathing-based detection of genetic point mutation visualized by naked eye.

    PubMed

    Xie, Liping; Wang, Tongzhou; Huang, Tianqi; Hou, Wei; Huang, Guoliang; Du, Yanan

    2014-09-09

    A novel label-free method based on breathing-induced vapor condensation was developed for detection of genetic point mutation. The dew-inspired detection was realized by integration of target-induced DNA ligation with rolling circle amplification (RCA). The vapor condensation induced by breathing transduced the RCA-amplified variances in DNA contents into visible contrast. The image could be recorded by a cell phone for further or even remote analysis. This green assay offers a naked-eye-reading method potentially applied for point-of-care liver cancer diagnosis in resource-limited regions.

  1. Ultra-high temperature isothermal furnace liners (IFLS) for copper freeze point cells

    NASA Astrophysics Data System (ADS)

    Dussinger, P. M.; Tavener, J. P.

    2013-09-01

    Primary Laboratories use large fixed-point cells in deep calibration furnaces utilizing heat pipes to achieve temperature uniformity. This combination of furnace, heat pipe, and cell gives the smallest of uncertainties. The heat pipe, also known as an isothermal furnace liner (IFL), has typically been manufactured with Alloy 600/601 as the envelope material since the introduction of high temperature IFLs over 40 years ago. Alloy 600/601 is a widely available high temperature material, which is compatible with Cesium, Potassium, and Sodium and has adequate oxidation resistance and reasonable high temperature strength. Advanced Cooling Technologies, Inc. (ACT) Alloy 600/Sodium IFLs are rated to 1100°C for approximately 1000 hours of operation (based on creep strength). Laboratories interested in performing calibrations and studies around the copper freezing point (1084.62°C) were frustrated by the 1000 hours at 1100°C limitation and the fact that expensive freeze-point cells were getting stuck and/or crushed inside the IFL. Because of this growing frustration/need, ACT developed an Ultra High Temperature IFL to take advantage of the exceptional high temperature strength properties of Haynes 230.

  2. Non-contact local temperature measurement inside an object using an infrared point detector

    NASA Astrophysics Data System (ADS)

    Hisaka, Masaki

    2017-04-01

    Local temperature measurement in deep areas of objects is an important technique in biomedical measurement. We have investigated a non-contact method for measuring temperature inside an object using a point detector for infrared (IR) light. An IR point detector with a pinhole was constructed and the radiant IR light emitted from the local interior of the object is photodetected only at the position of pinhole located in imaging relation. We measured the thermal structure of the filament inside the miniature bulb using the IR point detector, and investigated the temperature dependence at approximately human body temperature using a glass plate positioned in front of the heat source.

  3. High-Temperature Gas-Cooled Test Reactor Point Design

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sterbentz, James William; Bayless, Paul David; Nelson, Lee Orville

    2016-04-01

    A point design has been developed for a 200 MW high-temperature gas-cooled test reactor. The point design concept uses standard prismatic blocks and 15.5% enriched UCO fuel. Reactor physics and thermal-hydraulics simulations have been performed to characterize the capabilities of the design. In addition to the technical data, overviews are provided on the technological readiness level, licensing approach and costs.

  4. [Examination of upper airway function using the dew point hygrometer with semiconductor detector].

    PubMed

    Weremczuk, Jerzy; Paczesny, Daniel; Rapiejko, Piotr; Jachowicz, Ryszard; Jurkiewicz, Dariusz

    2005-09-01

    The nasal mucosa with blood capillary network has a remarkable role in respiration process. The most important nose functions are heating and humidifying to optimal level of reaching throat and lungs air and partly absorption of humidity and temperature from expired air. Variations of humidifying and heating processes can invoke some upper airways disorders. The paper presents dew point hygrometer which was specially design for laryngological purposes. The hygrometer can measure dynamic changes of humidity in upper airways. The device is fully automated, easy to operate and can communicate with external personal computer. Database application allows saving patient data with archive examination results and can display them easily. During ongoing clinical tests, still increasing amount of data will allow precisely investigate correlations between humidifying process and some diseases. The main advantage of the device is a short response time on humidity changing. The number of readings (detections) can reach 5 readings per second (slightly depending on humidity level) which is much faster than in available on the market hygrometers with sorption sensors. The paper also presents some results obtained in group of healthy volunteers and one patient with tracheostomy The tests figured out actual humidity in certain parts of upper airways: nose, throat, trachea in breathing cycles under various surrounding conditions. The constructed hygrometer can be used for air humidity measurement in upper airways during some diseases and for evaluation of an influence of some drugs and environmental conditions changing on air upper ways mucosa.

  5. Comparison of the Argon Triple-Point Temperature in Small Cells of Different Construction

    NASA Astrophysics Data System (ADS)

    Kołodziej, B.; Kowal, A.; Lipiński, L.; Manuszkiewicz, H.; Szmyrka-Grzebyk, A.

    2017-06-01

    The argon triple point (T_{90} = 83.8058 \\hbox {K}) is a fixed point of the International Temperature Scale of Preston-Thomas (Metrologia 27:3, 1990). Cells for realization of the fixed point have been manufactured by several European metrology institutes (Pavese in Metrologia 14:93, 1978; Pavese et al. in Temperature, part 1, American Institute of Physics, College Park, 2003; Hermier et al. in Temperature, part 1, American Institute of Physics, College Park, 2003; Pavese and Beciet in Modern gas-based temperature and pressure measurement, Springer, New York, 2013). The Institute of Low Temperature and Structure Research has in its disposal a few argon cells of various constructions used for calibration of capsule-type standard platinum resistance thermometers (CSPRT) that were produced within 40 years. These cells differ in terms of mechanical design and thermal properties, as well as source of gas filling the cell. This paper presents data on differences between temperature values obtained during the realization of the triple point of argon in these cells. For determination of the temperature, a heat-pulse method was applied (Pavese and Beciet in Modern gas-based temperature and pressure measurement, Springer, New York, 2013). The comparisons were performed using three CSPRTs. The temperatures difference was determined in relation to a reference function W(T)=R(T_{90})/R(271.16\\hbox {K}) in order to avoid an impact of CSPRT resistance drift between measurements in the argon cells. Melting curves and uncertainty budgets of the measurements are given in the paper. A construction of measuring apparatus is also presented in this paper.

  6. Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Paiva, Kleber; Mantelli, Marcia

    2011-01-01

    The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly accomplished by cold biasing the reservoir and using electrical heaters to provide the required control power. Using this method, the loop operating temperature can be controlled within +/- 0.5K. However, because of the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP has been carried out to investigate the effects on the LHP operation when the control temperature sensor is placed on the heat source instead of the reservoir. In these tests, the LHP reservoir is cold-biased and is heated by a control heater. Tests results show that it is feasible to use the heat source temperature for feedback control of the LHP operation. Using this method, the heat source temperature can be maintained within a tight range for moderate and high powers. At low powers, however, temperature oscillations may occur due to interactions among the reservoir control heater power, the heat source mass, and the heat output from the heat source. In addition, the heat source temperature could temporarily deviate from its set point during fast thermal transients. The implication is that more sophisticated feedback control algorithms need to be implemented for LHP transient operation when the heat source temperature is used for feedback control.

  7. Estimation of dew yield from radiative condensers by means of an energy balance model

    NASA Astrophysics Data System (ADS)

    Maestre-Valero, J. F.; Ragab, R.; Martínez-Alvarez, V.; Baille, A.

    2012-08-01

    SummaryThis paper presents an energy balance modelling approach to predict the nightly water yield and the surface temperature (Tf) of two passive radiative dew condensers (RDCs) tilted 30° from horizontal. One was fitted with a white hydrophilic polyethylene foil recommended for dew harvest and the other with a black polyethylene foil widely used in horticulture. The model was validated in south-eastern Spain by comparing the simulation outputs with field measurements of Tf and dew yield. The results indicate that the model is robust and accurate in reproducing the behaviour of the two RDCs, especially in what refers to Tf, whose estimates were very close to the observations. The results were somewhat less precise for dew yield, with a larger scatter around the 1:1 relationship. A sensitivity analysis showed that the simulated dew yield was highly sensitive to changes in relative humidity and downward longwave radiation. The proposed approach provides a useful tool to water managers for quantifying the amount of dew that could be harvested as a valuable water resource in arid, semiarid and water stressed regions.

  8. Evaluation of near-surface temperature, humidity, and equivalent temperature from regional climate models applied in type II downscaling

    NASA Astrophysics Data System (ADS)

    Pryor, S. C.; Schoof, J. T.

    2016-04-01

    Atmosphere-surface interactions are important components of local and regional climates due to their key roles in dictating the surface energy balance and partitioning of energy transfer between sensible and latent heat. The degree to which regional climate models (RCMs) represent these processes with veracity is incompletely characterized, as is their ability to capture the drivers of, and magnitude of, equivalent temperature (Te). This leads to uncertainty in the simulation of near-surface temperature and humidity regimes and the extreme heat events of relevance to human health, in both the contemporary and possible future climate states. Reanalysis-nested RCM simulations are evaluated to determine the degree to which they represent the probability distributions of temperature (T), dew point temperature (Td), specific humidity (q) and Te over the central U.S., the conditional probabilities of Td|T, and the coupling of T, q, and Te to soil moisture and meridional moisture advection within the boundary layer (adv(Te)). Output from all RCMs exhibits discrepancies relative to observationally derived time series of near-surface T, q, Td, and Te, and use of a single layer for soil moisture by one of the RCMs does not appear to substantially degrade the simulations of near-surface T and q relative to RCMs that employ a four-layer soil model. Output from MM5I exhibits highest fidelity for the majority of skill metrics applied herein, and importantly most realistically simulates both the coupling of T and Td, and the expected relationships of boundary layer adv(Te) and soil moisture with near-surface T and q.

  9. High temperature antenna pointing mechanism for BepiColombo mission

    NASA Astrophysics Data System (ADS)

    Mürer, Johan A.; Harper, Richard; Anderson, Mike

    2005-07-01

    This paper describes the two axis Antenna Pointing Mechanism (APM) with dual frequency (X-Ka bands) Rotary Joint (RJ) developed by Kongsberg Defence and Aerospace and BAE Systems, in the frame of the ESA BepiColombo mission to the planet Mercury. The extreme environmental conditions induced by Mercury's proximity to the Sun (up to 14.500 W/m2 direct solar fluxes, up to 5000 W/m2 infrared flux and up to 1200 W/m2 albedo shine form the planet surface), have dictated the need for a specific high temperature development of the pointing mechanism and of its integrated RF Rotary Joint. Global thermal analysis of the antenna predicts qualification temperature for the elevation stage APM between 250°C and 295°C. In addition, the mechanism shall survive extreme cold temperatures during the interplanetary cruise phase. Beside the harsh environment, the stringent pointing accuracy required by the antenna high frequency operations, and the extreme dimensional stability demanded by a radio science experiment (which is using the antenna for range and range rate measurements), have introduced additional, specific challenges to the mechanism design. Innovative solutions have been deemed necessary at system architecture level, in the design of the mechanisms critical areas and in the selection of high temperature compatible materials and processes. The very high working temperature of the mechanism ruled out use of aluminium alloys, which is replaced by Titanium alloy and stainless steels. Special heat treatments of the steel are applied for minimum loss of hardness. The structures are optimised for minimum mass. To handle thermal stresses and distortion, a very compact design of the APM was performed integrating the bearings, position sensor and drive chain within minimum structural length. The Rotary Joint is a unique design tailored to the APM using a common main bearing support. Special manufacturing processes have been tested and applied for manufacture of the very compact

  10. Investigation on the pinch point position in heat exchangers

    NASA Astrophysics Data System (ADS)

    Pan, Lisheng; Shi, Weixiu

    2016-06-01

    The pinch point is important for analyzing heat transfer in thermodynamic cycles. With the aim to reveal the importance of determining the accurate pinch point, the research on the pinch point position is carried out by theoretical method. The results show that the pinch point position depends on the parameters of the heat transfer fluids and the major fluid properties. In most cases, the pinch point locates at the bubble point for the evaporator and the dew point for the condenser. However, the pinch point shifts to the supercooled liquid state in the near critical conditions for the evaporator. Similarly, it shifts to the superheated vapor state with the condensing temperature approaching the critical temperature for the condenser. It even can shift to the working fluid entrance of the evaporator or the supercritical heater when the heat source fluid temperature is very high compared with the absorbing heat temperature. A wrong position for the pinch point may generate serious mistake. In brief, the pinch point should be founded by the iterative method in all conditions rather than taking for granted.

  11. Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Paiva, Kleber; Mantelli, Marcia

    2011-01-01

    Loop heat pipes (LHPs) have been used for thermal control of several NASA and commercial orbiting spacecraft. The LHP operating temperature is governed by the saturation temperature of its compensation chamber (CC). Most LHPs use the CC temperature for feedback control of its operating temperature. There exists a thermal resistance between the heat source to be cooled by the LHP and the LHP's CC. Even if the CC set point temperature is controlled precisely, the heat source temperature will still vary with its heat output. For most applications, controlling the heat source temperature is of most interest. A logical question to ask is: "Can the heat source temperature be used for feedback control of the LHP operation?" A test program has been implemented to answer the above question. Objective is to investigate the LHP performance using the CC temperature and the heat source temperature for feedback control

  12. Urban dew and rain in Paris, France: Occurrence and physico-chemical characteristics

    NASA Astrophysics Data System (ADS)

    Beysens, D.; Mongruel, A.; Acker, K.

    2017-06-01

    This paper summarizes one year (April 2011 to March 2012) measurements on planar condensing surfaces of dew and rain events and related physico-chemical characteristics in the urban environment of Paris (city center). Yearly collected water was 3.48 mm for dew (63 events) and 593 mm for rain (146 events). The latter value compares well with rain data (547 mm and 107 events) collected within 12 km at Paris-Orly airport. An estimation of dew yield based on meteo data gives 2.35 mm and 74 events, to be compared with 17.11 mm and 196 events at Paris-Orly. These differences highlight the large reduction in dew events and dew yields in an urban area as compared to a close rural-like area. This reduction is not due to a sky view reduction but to heat island that increases air temperature and decreases relative humidity. Analysis of dew (34) and rain (77) samples were done concerning pH, electrical conductivity (EC), major anions and cations as well as selected trace metals and other minor ions. Mean pH values are found similar for both, dew (6.5) and rain (6.1), rain being slightly more acidic than dew. The mean dew total ionic content (TIC 1.8 meq/l) and EC value (124 μS/cm) are about four times that of rain (0.45 meq/l; 35 μS/cm), meaning that total dissolved solids in dew is nearly four times that in rain. Sulfate and nitrate are the most acidifying components, calcium the most neutralizing constituent with ratio of mean total acidity/total alkalinity comparable for dew and rain ( 0.9). Sulfate and nitrate have mainly anthropogenic sources, whereas chloride and magnesium are mostly connected with marine air masses. Dew is a considerable factor of wet deposition of pollutants; dew and rain ion concentrations, however, meet the WHO requirements for drinking water.

  13. Thermal reference points as an index for monitoring body temperature in marine mammals.

    PubMed

    Melero, Mar; Rodríguez-Prieto, Víctor; Rubio-García, Ana; García-Párraga, Daniel; Sánchez-Vizcaíno, José Manuel

    2015-09-04

    Monitoring body temperature is essential in veterinary care as minor variations may indicate dysfunction. Rectal temperature is widely used as a proxy for body temperature, but measuring it requires special equipment, training or restraining, and it potentially stresses animals. Infrared thermography is an alternative that reduces handling stress, is safer for technicians and works well for untrained animals. This study analysed thermal reference points in five marine mammal species: bottlenose dolphin (Tursiops truncatus); beluga whale (Delphinapterus leucas); Patagonian sea lion (Otaria flavescens); harbour seal (Phoca vitulina); and Pacific walrus (Odobenus rosmarus divergens). The thermogram analysis revealed that the internal blowhole mucosa temperature is the most reliable indicator of body temperature in cetaceans. The temperatures taken during voluntary breathing with a camera held perpendicularly were practically identical to the rectal temperature in bottlenose dolphins and were only 1 °C lower than the rectal temperature in beluga whales. In pinnipeds, eye temperature appears the best parameter for temperature control. In these animals, the average times required for temperatures to stabilise after hauling out, and the average steady-state temperature values, differed according to species: Patagonian sea lions, 10 min, 31.13 °C; harbour seals, 10 min, 32.27 °C; Pacific walruses, 5 min, 29.93 °C. The best thermographic and most stable reference points for monitoring body temperature in marine mammals are open blowhole in cetaceans and eyes in pinnipeds.

  14. Dew point effect of cooled hydrogel pads on human stratum corneum biosurface.

    PubMed

    Xhauflaire-Uhoda, Emmanuelle; Paquet, Philippe; Piérard, Gérald E

    2008-01-01

    Cooled hydrogel pads are used to prevent overheating effects of laser therapy. They do not induce cold injuries to the skin, but their more subtle physiological effects have not been thoroughly studied. To describe the changes in transepidermal water loss and electrometric properties of the skin surface following application of cooled hydrogel pads. Measurements were performed on normal forearm skin of 27 healthy volunteers and on freshly excised skin from abdominoplasty. LaserAid hydrogel pads cooled to 4 degrees C were placed for 15 min on the forearm skin. Measurements of transepidermal water loss (TEWL) and electrometric properties (Corneometer, Nova DPM 900) were performed before application and after removal of the cooled pads. A consistent increase in corneometer units, dermal phase meter (DPM) values and TEWL were recorded at removal of the cooled hydrogel pads. Both the in vivo and in vitro assessments brought similar information. The similar changes disclosed in vitro and in vivo suggest that a common physical process is operating in these conditions. The observed phenomenon is opposite to the predicted events given by the Arrhenius law probably because of the combination of cooling and occlusion by the pads. A dew point effect (air temperature at which relative humidity is maximal) is likely involved in the moisture content of the stratum corneum. Thus, the biological impact of using cooling hydrogel pads during laser therapy is different from the effect of a cryogenic spray cooling procedure. The better preservation of the water balance in the stratum corneum by the cooled hydrogel pads could have a beneficial esthetic effect on laser treated areas. (c) 2008 S. Karger AG, Basel.

  15. Modeling of Aerobrake Ballute Stagnation Point Temperature and Heat Transfer to Inflation Gas

    NASA Technical Reports Server (NTRS)

    Bahrami, Parviz A.

    2012-01-01

    A trailing Ballute drag device concept for spacecraft aerocapture is considered. A thermal model for calculation of the Ballute membrane temperature and the inflation gas temperature is developed. An algorithm capturing the most salient features of the concept is implemented. In conjunction with the thermal model, trajectory calculations for two candidate missions, Titan Explorer and Neptune Orbiter missions, are used to estimate the stagnation point temperature and the inflation gas temperature. Radiation from both sides of the membrane at the stagnation point and conduction to the inflating gas is included. The results showed that the radiation from the membrane and to a much lesser extent conduction to the inflating gas, are likely to be the controlling heat transfer mechanisms and that the increase in gas temperature due to aerodynamic heating is of secondary importance.

  16. Surface acoustic wave transducer used for determination of the dew point in measurements of air relative humidity

    NASA Astrophysics Data System (ADS)

    Golebiowski, Jacek

    1995-06-01

    The devices to the measurement of air relative humidity with the surface acoustic wave transducers were presented. The relative humidity of air were measured by the determination of the dew point. The results of the investigations that were carried out were described and discussed.

  17. A dew point signaller for conservation of works of art.

    PubMed

    Camuffo, D; Valcher, S

    1986-03-01

    All works of art, from paintings, frescoes, sculptures, to monuments and buildings, are affected by diurnal and seasonal variations of the local microclimate, which induce interactions with the environmental atmosphere. Heat and vapour exchanges cause fluxes of heat and mass between the surface and the atmosphere, and may favour the agressivity of environmental pollutants. Condensation-evaporation cycles are recognized as being very important processes which adversely affect the life-time of the work of art. The need to control the microclimate or to stop condensation processes has been resolved by means of a dew-point signaller especially designed to overcome this problem. This paper discusses the characteristics of this device as well as the environmental philosophy which should be followed when conserving works of art.

  18. A pilot study to investigate the effects of combined dehumidification and HEPA filtration on dew point and airborne mold spore counts in day care centers.

    PubMed

    Bernstein, J A; Levin, L; Crandall, M S; Perez, A; Lanphear, B

    2005-12-01

    Meteorological factors such as relative humidity directly correlate with airborne fungal levels outdoors and indoors. While dehumidification alone is effective at reducing moisture necessary for mold growth, it is inadequate as a single intervention as it does not remove viable and non-viable fungal spores that are potentially allergenic. The purpose of this pilot study was to investigate whether dehumidification in combination with high-efficiency particulate arrestance (HEPA) filtration is effective at reducing airborne mold spore levels in day care centers. Two day care centers within a 2-mile radius of each other were selected. Day care center A was 2 years old with eight rooms while day care center B was 15 years old with six rooms. A high efficiency Santa Fe dehumidification unit equipped with a HEPA filter was installed in half the rooms (intervention) of each day care facility. Electronic HOBO data loggers continuously measured outdoor and indoor room dew point and temperature every 2 h throughout the study. Dew point and airborne fungal spore measurements from selected rooms with controlled air conditions were analyzed by comparing baseline measurements to those obtained at subsequent time periods over 1 year. Regression models accounted for correlations between measurements in the same room over time. Intervention resulted in a lowered average dew point from baseline by 8.8 degrees C compared with a decrease of 7.1 degrees C in non-intervention rooms across all time periods in both facilities (P<0.001). Fungal analyses demonstrated lower baseline (P=0.06) and follow-up means in intervention rooms (P<0.05), however the change from baseline to end of follow-up differed between intervention and non-intervention rooms in the two facilities. Log transformation was applied to approximate normality of fungal measurements. Dehumidification with HEPA filtration was effective at controlling indoor dew point in both facilities and at reducing airborne culturable

  19. A physically based analytical spatial air temperature and humidity model

    NASA Astrophysics Data System (ADS)

    Yang, Yang; Endreny, Theodore A.; Nowak, David J.

    2013-09-01

    Spatial variation of urban surface air temperature and humidity influences human thermal comfort, the settling rate of atmospheric pollutants, and plant physiology and growth. Given the lack of observations, we developed a Physically based Analytical Spatial Air Temperature and Humidity (PASATH) model. The PASATH model calculates spatial solar radiation and heat storage based on semiempirical functions and generates spatially distributed estimates based on inputs of topography, land cover, and the weather data measured at a reference site. The model assumes that for all grids under the same mesoscale climate, grid air temperature and humidity are modified by local variation in absorbed solar radiation and the partitioning of sensible and latent heat. The model uses a reference grid site for time series meteorological data and the air temperature and humidity of any other grid can be obtained by solving the heat flux network equations. PASATH was coupled with the USDA iTree-Hydro water balance model to obtain evapotranspiration terms and run from 20 to 29 August 2010 at a 360 m by 360 m grid scale and hourly time step across a 285 km2 watershed including the urban area of Syracuse, NY. PASATH predictions were tested at nine urban weather stations representing variability in urban topography and land cover. The PASATH model predictive efficiency R2 ranged from 0.81 to 0.99 for air temperature and 0.77 to 0.97 for dew point temperature. PASATH is expected to have broad applications on environmental and ecological models.

  20. Analysis of Screen Channel LAD Bubble Point Tests in Liquid Oxygen at Elevated Temperature

    NASA Technical Reports Server (NTRS)

    Hartwig, Jason; McQuillen, John

    2011-01-01

    The purpose of this paper is to examine the key parameters that affect the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid oxygen at elevated pressures and temperatures. An in depth analysis of the effect of varying temperature, pressure, and pressurization gas on bubble point is presented. Testing of a 200 x 1400 and 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenics Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 92 to 130K and 0.138 - 1.79 MPa. Bubble point is shown to be a strong function of temperature with a secondary dependence on pressure. The pressure dependence is believed to be a function of the amount of evaporation and condensation occurring at the screen. Good agreement exists between data and theory for normally saturated liquid but the model generally under predicts the bubble point in subcooled liquid. Better correlation with the data is obtained by using the liquid temperature at the screen to determine surface tension of the fluid, as opposed to the bulk liquid temperature.

  1. High Temperature Gas-Cooled Test Reactor Point Design: Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sterbentz, James William; Bayless, Paul David; Nelson, Lee Orville

    2016-01-01

    A point design has been developed for a 200-MW high-temperature gas-cooled test reactor. The point design concept uses standard prismatic blocks and 15.5% enriched uranium oxycarbide fuel. Reactor physics and thermal-hydraulics simulations have been performed to characterize the capabilities of the design. In addition to the technical data, overviews are provided on the technology readiness level, licensing approach, and costs of the test reactor point design.

  2. High Temperature Gas-Cooled Test Reactor Point Design: Summary Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sterbentz, James William; Bayless, Paul David; Nelson, Lee Orville

    2016-03-01

    A point design has been developed for a 200-MW high-temperature gas-cooled test reactor. The point design concept uses standard prismatic blocks and 15.5% enriched uranium oxycarbide fuel. Reactor physics and thermal-hydraulics simulations have been performed to characterize the capabilities of the design. In addition to the technical data, overviews are provided on the technology readiness level, licensing approach, and costs of the test reactor point design.

  3. The effect of temperature on pinning mechanisms in HTS composites

    NASA Astrophysics Data System (ADS)

    Sotnikova, A. P.; Rudnev, I. A.

    2016-09-01

    Pinning mechanism in samples of second generation tapes (2G) of high-temperature superconductors (HTS) was studied The critical current and the pinning force were calculated from the magnetization curves measured in the temperature range of 4.2 - 77 K in magnetic fields up to 14 Tesla using vibration sample magnetometer. To determine the pinning mechanism the dependences of pinning force on magnetic field were constructed according to the Dew-Hughes model and Kramer's rule. The obtained dependences revealed a significant influence of the temperature on effectiveness of different types of pinning. At low temperatures the 2G HTS tapes of different manufacturers demonstrated an equal efficiency of the pinning centers but with temperature increase the differences in pinning mechanisms as well as in properties and effectiveness of the pinning centers become obvious. The influence of the pinning mechanism on the energy losses in HTS tapes was shown.

  4. Variational analysis of temperature and moisture advection in a severe storm environment

    NASA Technical Reports Server (NTRS)

    Mcfarland, M. J.; Sasaki, Y. K.

    1977-01-01

    Horizontal wind components, potential temperature, and mixing ratio fields associated with a severe storm environment in the south central United States were objectively analyzed from synoptic upper air observations with a nonhomogeneous anisotropic weighting function. The particular case study discussed here is the tornado producting squall line which moved through eastern Oklahoma 26 May 1973. The synoptic situation which preceded squall line development was cyclogenesis and frontogenesis in the lee-of-mountain trough, which produced a well-defined surface dry line (or dew point front) and a pronounced mid-level dry air intrusion. It is shown that the intrusion was also characterized by warm air, with a lapse rate approaching the dry adiabatic.

  5. Applicability of low-melting-point microcrystalline wax to develop temperature-sensitive formulations.

    PubMed

    Matsumoto, Kohei; Kimura, Shin-Ichiro; Iwao, Yasunori; Itai, Shigeru

    2017-10-30

    Low-melting-point substances are widely used to develop temperature-sensitive formulations. In this study, we focused on microcrystalline wax (MCW) as a low-melting-point substance. We evaluated the drug release behavior of wax matrix (WM) particles using various MCW under various temperature conditions. WM particles containing acetaminophen were prepared using a spray congealing technique. In the dissolution test at 37°C, WM particles containing low-melting-point MCWs whose melting was starting at approx. 40°C (Hi-Mic-1045 or 1070) released the drug initially followed by the release of only a small amount. On the other hand, in the dissolution test at 20 and 25°C for WM particles containing Hi-Mic-1045 and at 20, 25, and 30°C for that containing Hi-Mic-1070, both WM particles showed faster drug release than at 37°C. The characteristic drug release suppression of WM particles containing low-melting-point MCWs at 37°C was thought attributable to MCW melting, as evidenced by differential scanning calorimetry analysis and powder X-ray diffraction analysis. Taken together, low-melting-point MCWs may be applicable to develop implantable temperature-sensitive formulations that drug release is accelerated by cooling at administered site. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Temperature influence on the cladding mode distribution in highly localized point-by-point fibre Bragg gratings

    NASA Astrophysics Data System (ADS)

    Caucheteur, C.; Gonzalez-Vila, A.; Chikh-Bled, H.; Lasri, B.; Kinet, D.; Chah, K.

    2016-05-01

    An infrared femtosecond pulses laser is used to manufacture point-by-point gratings in telecommunication-grade optical fibres. The refractive index modulations are localized close to the core-cladding interface, yielding a strong coupling to cladding mode resonances together with an important photo-induced birefringence. Such gratings have been recently used for refractrometric measurements. In this work, their transmitted amplitude spectrum is measured with polarized light while they are exposed to temperature changes up to 900 °C. Despite an overall good thermal stability of the gratings that confirms their robustness for high-temperature refractometry, we report an interesting polarization effect depending on both the cladding mode resonance family (radially- and azimuthally-polarized modes) and mode order. While the birefringence of the core mode resonance decreases with the temperature, certain cladding mode resonances show an increase of the wavelength splitting between their orthogonally-polarized components. This differential behaviour can be of high interest to develop high-resolution multiparametric sensing platforms.

  7. Dew and hoarfrost frequency, formation efficiency and chemistry in Wroclaw, Poland

    NASA Astrophysics Data System (ADS)

    Gałek, G.; Sobik, M.; Błaś, M.; Polkowska, Ż.; Cichała-Kamrowska, K.; Wałaszek, K.

    2015-01-01

    This article presents the results of a research study concerning a comparison of frequency, formation efficiency and basic physico-chemical properties of dew and hoarfrost in urban conditions. Longer than two-year series of measurements was carried out from 1 February 2008 to 10 March 2010 in Wroclaw, Poland. Sampling of atmospheric deposits was made by means of insulated plain passive radiative condensers, which allowed to collect 222 dew and 96 hoarfrost samples. The results indicate that the frequency of dew days was about threefold greater than hoarfrost days. The formation efficiency of both types of deposits was almost the same, and reached a mean value of about 100 mL·m- 2 per day. The conducted analysis of several meteorological parameters showed that dew and hoarfrost, despite seasonal weather changes, were formed in very similar meteorological conditions. Only water vapor pressure values were in average twice higher in the case of dew and the impact of this parameter on dew and hoarfrost formation efficiency seems to be more complex than expected. The role of night duration in counterbalancing of smaller amount of available moisture in hoarfrost days is not clear. The investigation showed also, that there was an expected clear positive dependence of dew and hoarfrost formation efficiency on relative humidity, and not so evident in the case of temperature inversion, and wind velocity. The physico-chemical analysis indicated that the pH of dew was only slightly lower than the hoarfrost ones, regardless of the deposit formation intensity. Simultaneously, the lower pH values were much more frequent in the case of dew, which resulted from more effective absorption of anthropogenic NO3- and SO42 - ions. For both types of deposits, the average pH was low (4.5-4.8) in relation to majority of studies reported in literature. In spite of seasonal changes of pollutant concentration, various weather conditions and different mechanisms of pollutant absorption of dew

  8. Inventory of File nam.t00z.smartconus06.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 6 hour fcst Dew Point Temperature [K] 003 surface SPFH 6 hour fcst Specific Index [K] 027 surface HINDEX 6 hour fcst Haines Index [Numeric] 028 surface TMP 5 hour fcst Temperature [K] 029 surface TMP 4 hour fcst Temperature [K] 030 surface DPT 5 hour fcst Dew Point Temperature [K

  9. Inventory of File gfs.t06z.smartguam12.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific Best (4 layer) Lifted Index [K] 020 surface TMP 11 hour fcst Temperature [K] 021 surface TMP 10 hour fcst Temperature [K] 022 surface DPT 11 hour fcst Dew Point Temperature [K] 023 surface DPT 10 hour

  10. Inventory of File nam.t00z.smartconus12.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 12 hour fcst Dew Point Temperature [K] 003 surface SPFH 12 hour fcst Specific hour fcst Haines Index [Numeric] 030 surface TMP 11 hour fcst Temperature [K] 031 surface TMP 10 hour fcst Temperature [K] 032 surface DPT 11 hour fcst Dew Point Temperature [K] 033 surface DPT 10 hour

  11. Eating Quality Traits of Hanwoo longissimus dorsi Muscle as a Function of End-Point Cooking Temperature

    PubMed Central

    2016-01-01

    Interaction between carcass quality grade and end-point cooking temperature on eating quality of Hanwoo m. longissimus was investigated. Ten (10) of steers were sampled from a commercial population; carcasses with QG 1++ (n=5) and QG 1 (n=5) were chosen. Samples were cooked by electric oven at 60 or 82℃ and compared with uncooked control samples. The pH was not affected by cooking temperature but decreased the redness after cooking and steaks cooked at 60℃ were more reddish than steaks cooked at 82℃ in both QG groups. Higher cooking temperature greatly (p<0.05) increased the cooking loss, but there was no significant interaction between cooking temperature and QG on the cooking loss. Moisture is negatively correlated with temperature in both QG while the proportionate relationship between crude fat and end-point temperature found in QG 1++. WBSF values were significantly (p<0.05) high for QG 1, while that was significantly (p<0.05) increased when the temperature continues to increase. The increasing quality grade of beef resulted in significant higher (p<0.01) level of TBARS and cooking temperature increased TBARS content. Fatty acid composition was not altered by cooking at both temperatures and also the amount of fat intake was not changed. The current study indicates that eating quality of beef m. longissimus was greatly influenced by end-point temperature being interacted with QG. However, the amount and composition of fat were stable regardless of end-point temperatures. These results will provide a consumer reference to determine cooking conditions and intramuscular fat content. PMID:27433099

  12. Effects of leaf hair points of a desert moss on water retention and dew formation: implications for desiccation tolerance.

    PubMed

    Tao, Ye; Zhang, Yuan Ming

    2012-05-01

    Leaf hair points (LHPs) are important morphological structures in many desiccation-tolerant mosses, but study of their functions has been limited. A desert moss, Syntrichia caninervis, was chosen for examination of the ecological effects of LHPs on water retention and dew formation at individual and population (patch) levels. Although LHPs were only 4.77% of shoot weight, they were able to increase absolute water content (AWC) by 24.87%. The AWC of samples with LHPs was always greater than for those without LHPs during dehydration. The accumulative evaporation ratio (AER) showed an opposite trend. AWC, evaporation ratio and AER of shoots with LHPs took 20 min longer to reach a completely dehydrated state than shoots without LHPs. At the population level, dew formation on moss crusts with LHPs was faster than on crusts without LHPs, and the former had higher daily and total dew amounts. LHPs were able to improve dew amounts on crusts by 10.26%. Following three simulated rainfall events (1, 3 and 6 mm), AERs from crusts with LHPs were always lower than from crusts without LHPs. LHPs can therefore significantly delay and reduce evaporation. We confirm that LHPs are important desiccation-tolerant features of S. caninervis at both individual and population levels. LHPs greatly aid moss crusts in adapting to arid conditions.

  13. On the contribution of atmospheric moisture to dew formation

    NASA Astrophysics Data System (ADS)

    Garratt, J. R.; Segal, M.

    1988-09-01

    The relative contributions of dewfall (a flux of water vapour from air to surface) and distillation (a flux of water vapour from soil to canopy) to dew formation on closed canopy and bare soil surfaces are assessed, and the dependence of dew amount upon wind speed, absolute temperature, atmospheric stability, relative humidity, soil characteristics and cloudiness, all of which are significant factors, is evaluated. Some of these evaluations provide refinements to similar ones given in Monteith (1961). High dewfall rates are usually ≲0.06 mm hr-1 over canopy or bare soil, though upon a canopy under soil-saturated and air-saturated conditions, rates of dew formation may reach 0.07 0.09 mm hr-1 with contributions from distillation. Various sets of observations are reanalyzed to illustrate the importance of the horizontal advection of moisture in the nocturnal boundary layer (NBL) to observed high rates of dew formation arising from the atmospheric contribution of water vapour (dewfall). These locally observed high dewfall rates must be the result of small-scale or mesoscale horizontal advection of moisture in the NBL, since the humidity changes within the typically shallow NBL required to balance the loss of water at the surface are not observed. Over extensive areas of uniform surface (horizontal scales ≫10 km), such continuously high dewfall rates could only be balanced by a local supply of atmospheric moisture since advection of moisture would necessarily be small.

  14. Temperature Effects of Point Sources, Riparian Shading, and Dam Operations on the Willamette River, Oregon

    USGS Publications Warehouse

    Rounds, Stewart A.

    2007-01-01

    Water temperature is an important factor influencing the migration, rearing, and spawning of several important fish species in rivers of the Pacific Northwest. To protect these fish populations and to fulfill its responsibilities under the Federal Clean Water Act, the Oregon Department of Environmental Quality set a water temperature Total Maximum Daily Load (TMDL) in 2006 for the Willamette River and the lower reaches of its largest tributaries in northwestern Oregon. As a result, the thermal discharges of the largest point sources of heat to the Willamette River now are limited at certain times of the year, riparian vegetation has been targeted for restoration, and upstream dams are recognized as important influences on downstream temperatures. Many of the prescribed point-source heat-load allocations are sufficiently restrictive that management agencies may need to expend considerable resources to meet those allocations. Trading heat allocations among point-source dischargers may be a more economical and efficient means of meeting the cumulative point-source temperature limits set by the TMDL. The cumulative nature of these limits, however, precludes simple one-to-one trades of heat from one point source to another; a more detailed spatial analysis is needed. In this investigation, the flow and temperature models that formed the basis of the Willamette temperature TMDL were used to determine a spatially indexed 'heating signature' for each of the modeled point sources, and those signatures then were combined into a user-friendly, spreadsheet-based screening tool. The Willamette River Point-Source Heat-Trading Tool allows the user to increase or decrease the heating signature of each source and thereby evaluate the effects of a wide range of potential point-source heat trades. The predictions of the Trading Tool were verified by running the Willamette flow and temperature models under four different trading scenarios, and the predictions typically were accurate

  15. All-fiber Mach-Zehnder interferometer for tunable two quasi-continuous points' temperature sensing in seawater.

    PubMed

    Liu, Tianqi; Wang, Jing; Liao, Yipeng; Wang, Xin; Wang, Shanshan

    2018-04-30

    An all-fiber Mach-Zehnder interferometer (MZI) for two quasi-continuous points' temperature sensing in seawater is proposed. Based on the beam propagation theory, transmission spectrum is designed to present two sets of clear and independent interferences. Following this design, MZI is fabricated and two points' temperature sensing in seawater are demonstrated with sensitivities of 42.69pm/°C and 39.17pm/°C, respectively. By further optimization, sensitivity of 80.91pm/°C can be obtained, which is 3-10 times higher than fiber Bragg gratings and microfiber resonator, and higher than almost all similar MZI based temperature sensors. In addition, factors affecting sensitivities are also discussed and verified in experiment. The two points' temperature sensing demonstrated here show advantages of simple and compact construction, robust structure, easy fabrication, high sensitivity, immunity to salinity and tunable distance of 1-20 centimeters between two points, which may provide references for macroscopic oceanic research and other sensing applications based on MZIs.

  16. Inventory of File gfs.t06z.smartguam03.tm00.grib2

    Science.gov Websites

    Temperature [K] 002 surface DPT 3 hour fcst Dew Point Temperature [K] 003 surface SPFH 3 hour fcst Specific surface 4LFTX 3 hour fcst Best (4 layer) Lifted Index [K] 019 surface TMP 2 hour fcst Temperature [K] 020 surface TMP 1 hour fcst Temperature [K] 021 surface DPT 2 hour fcst Dew Point Temperature [K] 022 surface

  17. On the critical temperature, normal boiling point, and vapor pressure of ionic liquids.

    PubMed

    Rebelo, Luis P N; Canongia Lopes, José N; Esperança, José M S S; Filipe, Eduardo

    2005-04-07

    One-stage, reduced-pressure distillations at moderate temperature of 1-decyl- and 1-dodecyl-3-methylimidazolium bistriflilamide ([Ntf(2)](-)) ionic liquids (ILs) have been performed. These liquid-vapor equilibria can be understood in light of predictions for normal boiling points of ILs. The predictions are based on experimental surface tension and density data, which are used to estimate the critical points of several ILs and their corresponding normal boiling temperatures. In contrast to the situation found for relatively unstable ILs at high-temperature such as those containing [BF(4)](-) or [PF(6)](-) anions, [Ntf(2)](-)-based ILs constitute a promising class in which reliable, accurate vapor pressure measurements can in principle be performed. This property is paramount for assisting in the development and testing of accurate molecular models.

  18. Progress report for the CCT-WG5 high temperature fixed point research plan

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Machin, G.; Woolliams, E. R.; Anhalt, K.

    2013-09-11

    An overview of the progress in High Temperature Fixed Point (HTFP) research conducted under the auspices of the CCT-WG5 research plan is reported. In brief highlights are: Provisional long term stability of HTFPs has been demonstrated. Optimum construction methods for HTFPs have been established and high quality HTFPs of Co-C, Pt-C and Re-C have been constructed for thermodynamic temperature assignment. The major sources of uncertainty in the assignment of thermodynamic temperature have been identified and quantified. The status of absolute radiometric temperature measurement has been quantified through the circulation of a set of HTFPs. The measurement campaign to assign lowmore » uncertainty thermodynamic temperatures to a selected set of HTFPs will begin in mid-2012. It is envisaged that this will be complete by 2015 leading to HTFPs becoming routine reference standards for radiometry and high temperature metrology.« less

  19. Evaluation of methods for characterizing the melting curves of a high temperature cobalt-carbon fixed point to define and determine its melting temperature

    NASA Astrophysics Data System (ADS)

    Lowe, David; Machin, Graham

    2012-06-01

    The future mise en pratique for the realization of the kelvin will be founded on the melting temperatures of particular metal-carbon eutectic alloys as thermodynamic temperature references. However, at the moment there is no consensus on what should be taken as the melting temperature. An ideal melting or freezing curve should be a completely flat plateau at a specific temperature. Any departure from the ideal is due to shortcomings in the realization and should be accommodated within the uncertainty budget. However, for the proposed alloy-based fixed points, melting takes place over typically some hundreds of millikelvins. Including the entire melting range within the uncertainties would lead to an unnecessarily pessimistic view of the utility of these as reference standards. Therefore, detailed analysis of the shape of the melting curve is needed to give a value associated with some identifiable aspect of the phase transition. A range of approaches are or could be used; some purely practical, determining the point of inflection (POI) of the melting curve, some attempting to extrapolate to the liquidus temperature just at the end of melting, and a method that claims to give the liquidus temperature and an impurity correction based on the analytical Scheil model of solidification that has not previously been applied to eutectic melting. The different methods have been applied to cobalt-carbon melting curves that were obtained under conditions for which the Scheil model might be valid. In the light of the findings of this study it is recommended that the POI continue to be used as a pragmatic measure of temperature but where required a specified limits approach should be used to define and determine the melting temperature.

  20. Selective Oxidation of a 0.1C-6Mn-2Si Third Generation Advanced High-Strength Steel During Dew-Point Controlled Annealing

    NASA Astrophysics Data System (ADS)

    Pourmajidian, Maedeh; McDermid, Joseph R.

    2018-03-01

    The present study investigates the selective oxidation of a 0.1C-6Mn-2Si medium-Mn advanced high-strength steel during austenization annealing heat treatments as a function of process atmosphere oxygen partial pressure and annealing time. It was determined that the surface oxide growth kinetics followed a parabolic rate law with the minimum rate belonging to the lowest oxygen partial pressure atmosphere at a dew point of 223 K (- 50 °C). The chemistry of the surface and subsurface oxides was studied using STEM + EELS on the sample cross sections, and it was found that the surface oxides formed under the 223 K (- 50 °C) dew-point atmosphere consisted of a layered configuration of SiO2, MnSiO3, and MnO, while in the case of the higher pO2 process atmospheres, only MnO was detected at the surface. Consistent with the Wagner calculations, it was shown that the transition to internal oxidation for Mn occurred under the 243 K (- 30 °C) and 278 K (+ 5 °C) dew-point atmospheres. However, the predictions of the external to internal oxidation for Si using the Wagner model did not correlate well with the experimental findings nor did the predictions of the Mataigne et al. model for multi-element alloys. Investigations of the internal oxide network at the grain boundaries revealed a multilayer oxide structure composed of amorphous SiO2 and crystalline MnSiO3, respectively, at the oxide core and outer shell. A mechanism for the formation of the oxide morphologies observed, based on kinetic and thermodynamic factors, was proposed. It is expected that only the fine and nodule-like MnO oxides formed on the surface of the samples annealed under the 278 K (+ 5 °C) dew-point process atmosphere for 60 and 120 seconds are sufficiently thin and of the desired dispersed morphology to promote reactive wetting by the molten galvanizing bath.

  1. Biggs AAF, El Paso, Texas. Revised Uniform Summary of Surface Weather Observations (RUSSWO). Parts A-F

    DTIC Science & Technology

    1981-01-14

    wet-bulb temperature depression versus dry -bulb temperature, means and standard deviations of d-j-bulb, wet-bulb (over) SDD, 1473 UNCLASS IF I ED FC...distribution tables Dry -bulb temperature versud wet-bulb temperature Cumulative percentage frequency of distribution tables 20. and dew point...PART 5 PRECIPITATION PSYCHROMETRIC.DRY VS WET BULB SNOWFALL MEAN & STO 0EV SNOW EPTH DRY BULB, WET BULB, &DEW POINtI RELATIVE HUMIDITY PARTC SURFACE

  2. Vigilance system in rails for train hot point temperatures during circulation

    NASA Astrophysics Data System (ADS)

    Meca Meca, Francisco J.; Rodriguez Sanchez, Francisco J.; Mazo Quintas, Manuel; Garcia Dominguez, Juan J.; Fonolla Navarro, Rafael; Sebastian Martinez, Eduardo; Jimenez Calvo, Jose A.; Lillo Rodriguez, Diego; Garcia Garrido, Miguel A.

    2000-06-01

    Wheels, hubs and brake discs in a train during its circulation are under mechanical strains that make its temperature increase above the environment temperature. Mechanical defects in those elements produce an excessive friction and, as a consequence of it, an important increment of its temperature in relation to normal values. Detecting these anomalies is essential to avoid accidents and it is performed by fixed systems located next to rails which make infrared temperature measurements of hot points and send them to a supervisory station that takes the proper steps. The paper introduces the most important problems which must be dealt with during the designing stage of the measurement system. It also explains the solutions taken by the authors in order to assure the minimum operative aims demanded by the application. These problems includes: the choice of the detector and measurement method, communication with the supervisory station, and the environment conditions. Finally, the research lines followed by the authors in order to improve and extend the system's capabilities are explained.

  3. Temperature-profile detector

    DOEpatents

    Not Available

    1981-01-29

    Temperature profiles at elevated temperature conditions are monitored by use of an elongated device having two conductors spaced by the minimum distance required to normally maintain an open circuit between them. The melting point of one conductor is selected at the elevated temperature being detected, while the melting point of the other is higher. As the preselected temperature is reached, liquid metal will flow between the conductors creating short circuits which are detectable as to location.

  4. Temperature profile detector

    DOEpatents

    Tokarz, Richard D.

    1983-01-01

    Temperature profiles at elevated temperature conditions are monitored by use of an elongated device having two conductors spaced by the minimum distance required to normally maintain an open circuit between them. The melting point of one conductor is selected at the elevated temperature being detected, while the melting point of the other is higher. As the preselected temperature is reached, liquid metal will flow between the conductors, creating short circuits which are detectable as to location.

  5. Measurement of Sticky Point Temperature of Coffee Powder with a Rheometer

    USDA-ARS?s Scientific Manuscript database

    Sticky point temperature (Ts) measurement for hygroscopic food and biomaterial powders is traditionally performed with complex glass instruments. This property is used to characterize material stickiness, which substantially affects the flow and physical behavior of powders. In this research study w...

  6. Analysis of Screen Channel LAD Bubble Point Tests in Liquid Methane at Elevated Temperature

    NASA Technical Reports Server (NTRS)

    Hartwig, Jason; McQuillen, John

    2012-01-01

    This paper examines the effect of varying the liquid temperature and pressure on the bubble point pressure for screen channel Liquid Acquisition Devices in cryogenic liquid methane using gaseous helium across a wide range of elevated pressures and temperatures. Testing of a 325 x 2300 Dutch Twill screen sample was conducted in the Cryogenic Components Lab 7 facility at the NASA Glenn Research Center in Cleveland, Ohio. Test conditions ranged from 105 to 160K and 0.0965 - 1.78 MPa. Bubble point is shown to be a strong function of the liquid temperature and a weak function of the amount of subcooling at the LAD screen. The model predicts well for saturated liquid but under predicts the subcooled data.

  7. Comparing daily temperature averaging methods: the role of surface and atmosphere variables in determining spatial and seasonal variability

    NASA Astrophysics Data System (ADS)

    Bernhardt, Jase; Carleton, Andrew M.

    2018-05-01

    The two main methods for determining the average daily near-surface air temperature, twice-daily averaging (i.e., [Tmax+Tmin]/2) and hourly averaging (i.e., the average of 24 hourly temperature measurements), typically show differences associated with the asymmetry of the daily temperature curve. To quantify the relative influence of several land surface and atmosphere variables on the two temperature averaging methods, we correlate data for 215 weather stations across the Contiguous United States (CONUS) for the period 1981-2010 with the differences between the two temperature-averaging methods. The variables are land use-land cover (LULC) type, soil moisture, snow cover, cloud cover, atmospheric moisture (i.e., specific humidity, dew point temperature), and precipitation. Multiple linear regression models explain the spatial and monthly variations in the difference between the two temperature-averaging methods. We find statistically significant correlations between both the land surface and atmosphere variables studied with the difference between temperature-averaging methods, especially for the extreme (i.e., summer, winter) seasons (adjusted R2 > 0.50). Models considering stations with certain LULC types, particularly forest and developed land, have adjusted R2 values > 0.70, indicating that both surface and atmosphere variables control the daily temperature curve and its asymmetry. This study improves our understanding of the role of surface and near-surface conditions in modifying thermal climates of the CONUS for a wide range of environments, and their likely importance as anthropogenic forcings—notably LULC changes and greenhouse gas emissions—continues.

  8. The effect of environmental humidity and temperature on skin barrier function and dermatitis.

    PubMed

    Engebretsen, K A; Johansen, J D; Kezic, S; Linneberg, A; Thyssen, J P

    2016-02-01

    Physicians are aware that climatic conditions negatively affect the skin. In particular, people living in equator far countries such as the Northern parts of Europe and North America are exposed to harsh weather during the winter and may experience dry and itchy skin, or deterioration of already existing dermatoses. We searched the literature for studies that evaluated the mechanisms behind this phenomenon. Commonly used meteorological terms such as absolute humidity, relative humidity and dew point are explained. Furthermore, we review the negative effect of low humidity, low temperatures and different seasons on the skin barrier and on the risk of dermatitis. We conclude that low humidity and low temperatures lead to a general decrease in skin barrier function and increased susceptible towards mechanical stress. Since pro-inflammatory cytokines and cortisol are released by keratinocytes, and the number of dermal mast cells increases, the skin also becomes more reactive towards skin irritants and allergens. Collectively, published data show that cold and dry weather increase the prevalence and risk of flares in patients with atopic dermatitis. © 2015 European Academy of Dermatology and Venereology.

  9. Influence of Gas Atmosphere Dew Point on the Galvannealing of CMnSi TRIP Steel

    NASA Astrophysics Data System (ADS)

    Cho, Lawrence; Kim, Myung Soo; Kim, Young Ha; De Cooman, Bruno C.

    2013-11-01

    The Fe-Zn reaction occurring during the galvannealing of a Si-bearing transformation-induced plasticity (TRIP) steel was investigated by field-emission electron probe microanalysis and field-emission transmission electron microscopy. The galvannealing was simulated after hot dipping in a Zn bath containing 0.13 mass pct Al at 733 K (460 °C). The galvannealing temperature was in the range of 813 K to 843 K (540 °C to 570 °C). The kinetics and mechanism of the galvannealing reaction were strongly influenced by the gas atmosphere dew point (DP). After the galvannealing of a panel annealed in a N2+10 pct H2 gas atmosphere with low DPs [213 K and 243 K (-60 °C and -30 °C)], the coating layer consisted of δ (FeZn10) and η (Zn) phase crystals. The Mn-Si compound oxides formed during intercritical annealing were present mostly at the steel/coating interface after the galvannealing. Galvannealing of a panel annealed in higher DP [263 K and 273 K, and 278 K (-10 °C, 0 °C, and +5 °C)] gas atmospheres resulted in a coating layer consisting of δ and Г (Fe3Zn10) phase crystals, and a thin layer of Г 1 (Fe11Zn40) phase crystals at the steel/coating interface. The Mn-Si oxides were distributed homogeneously throughout the galvannealed (GA) coating layer. When the surface oxide layer thickness on panels annealed in a high DP gas atmosphere was reduced, the Fe content at the GA coating surface increased. Annealing in a higher DP gas atmosphere improved the coating quality of the GA panels because a thinner layer of oxides was formed. A high DP atmosphere can therefore significantly contribute to the suppression of Zn-alloy coating defects on CMnSi TRIP steel processed in hot dip galvanizing lines.

  10. Final report on EURAMET.T-K6.1: Bilateral comparison of the realisations of local dew/frost-point temperature scales in the range -70 °C to +20 °C

    NASA Astrophysics Data System (ADS)

    Heinonen, Martti; Zvizdic, Davor; Sestan, Danijel

    2013-01-01

    As the European extension of the first CCT humidity key comparison, EUROMET.T-K6 was successfully completed in year 2008. After this comparison, a new low dew-point generator was introduced at LPM in Croatia as a result of progress in the EUROMET P912 project. With this new facility, the LPM uncertainties decreased significantly and the operating range became significantly wider. Therefore, it was decided to arrange a bilateral comparison between LPM and MIKES in Finland providing a link to EUROMET.T-K6 and CCT-K6. This comparison was carried out in a manner similar to other K6 comparisons but only one transfer standard was used instead of two units and the measurement point -70 °C was added to the measurement scheme. At all measurement points, the bilateral equivalence was well within the estimated expanded uncertainty at the approximately 95% confidence level. Also, the deviations of the LPM results from the EUROMET.T-K6 reference values were smaller than their expanded uncertainties. Main text. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCT, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

  11. Investigation of TiC C Eutectic and WC C Peritectic High-Temperature Fixed Points

    NASA Astrophysics Data System (ADS)

    Sasajima, Naohiko; Yamada, Yoshiro

    2008-06-01

    TiC C eutectic (2,761°C) and WC C peritectic (2,749°C) fixed points were investigated to compare their potential as high-temperature thermometric reference points. Two TiC C and three WC C fixed-point cells were constructed, and the melting and freezing plateaux were evaluated by means of radiation thermometry. The repeatability of the TiC C eutectic within a day was 60 mK with a melting range roughly 200 mK. The repeatability of the melting temperature of the WC C peritectic within 1 day was 17 mK with a melting range of ˜70 mK. The repeatability of the freezing temperature of the WC C peritectic was 21 mK with a freezing range less than 20 mK. One of the TiC C cells was constructed from a TiC and graphite powder mixture. The filling showed the reaction with the graphite crucible was suppressed and the ingot contained less voids, although the lack of high-purity TiC powder poses a problem. The WC C cells were easily constructed, like metal carbon eutectic cells, without any evident reaction with the crucible. From these results, it is concluded that the WC C peritectic has more potential than the TiC C eutectic as a high-temperature reference point. The investigation of the purification of the TiC C cell during filling and the plateau observation are also reported.

  12. The initial freezing point temperature of beef rises with the rise in pH: a short communication.

    PubMed

    Farouk, M M; Kemp, R M; Cartwright, S; North, M

    2013-05-01

    This study tested the hypothesis that the initial freezing point temperature of meat is affected by pH. Sixty four bovine M. longissimus thoracis et lumborum were classified into two ultimate pH groups: low (<5.8) and high pH (>6.2) and their cooling and freezing point temperatures were determined. The initial freezing temperatures for beef ranged from -0.9 to -1.5°C (∆=0.6°C) with the higher and lower temperatures associated with high and low ultimate pH respectively. There was a significant correlation (r=+0.73, P<0.01) between beef pH and freezing point temperature in the present study. The outcome of this study has implications for the meat industry where evidence of freezing (ice formation) in a shipment as a result of high pH meat could result in a container load of valuable chilled product being downgraded to a lower value frozen product. Copyright © 2013 Elsevier Ltd. All rights reserved.

  13. 1935-2004 Water Vapor Trends at the Summit of Mount Washington, NH

    NASA Astrophysics Data System (ADS)

    Seidel, T. M.; Grant, A. N.; Pszenny, A. A.

    2005-12-01

    As part of an ongoing effort to digitize and analyze the unique historical climate record from the summit of Mount Washington, water vapor mixing ratios calculated from synoptic (six-hourly) sling psychrometer and related data will be presented. The Mount Washington Observatory, located at 44°16'N, 71°18'W, 1914 m ASL, has been recording meteorological conditions since 1932. A continuous record of hourly and synoptic data exists from 1935 to the present. Previous work with hourly temperature data has shown an increase in annual temperature of 0.3°C over this 69-year interval, with larger increases during spring and winter, and a decrease in diurnal temperature range (A. Grant et al., J. Climate, in press). Preliminary examination of the synoptic psychrometric data suggests a decrease in annual dew point of approximately 0.4°C, with larger decreases in fall and winter than during the other seasons. Decreasing dew points are expected under two conditions: drier air or constant water vapor with increasing temperature. Other dew point climatologies of the continental United States for the second half of the 20th century have shown mixed results, with increased dew points evident at some stations, decreased dew points at others, and no clear regional patterns.

  14. Heat Coma Temperature and Supercooling Point in Oceanic Sea Skaters (Heteroptera, Gerridae)

    PubMed Central

    Harada, Tetsuo

    2018-01-01

    Heat coma temperatures (HCTs) and super cooling points (SCPs) were examined for nearly 1000 oceanic sea skaters collected from in the Pacific and Indian Oceans representing four Halobates species; H. germanus, H. micans, H. sericeus, and H. sp. Analysis was conducted using the entire dataset because a negative correlation was seen between the HCTs and SCPs in all four species. A weak negative correlation was seen between HCTs and SCPs with a cross tolerance between warmer HCTs and colder SCPs. The weakness of the correlation may be due to the large size of the dataset and to the variability in ocean surface temperature. The negative correlation does however suggest that oceanic sea skaters may have some form of cross tolerance with a common physiological mechanism for their high and low temperature tolerances. PMID:29401693

  15. Statistical methods for change-point detection in surface temperature records

    NASA Astrophysics Data System (ADS)

    Pintar, A. L.; Possolo, A.; Zhang, N. F.

    2013-09-01

    We describe several statistical methods to detect possible change-points in a time series of values of surface temperature measured at a meteorological station, and to assess the statistical significance of such changes, taking into account the natural variability of the measured values, and the autocorrelations between them. These methods serve to determine whether the record may suffer from biases unrelated to the climate signal, hence whether there may be a need for adjustments as considered by M. J. Menne and C. N. Williams (2009) "Homogenization of Temperature Series via Pairwise Comparisons", Journal of Climate 22 (7), 1700-1717. We also review methods to characterize patterns of seasonality (seasonal decomposition using monthly medians or robust local regression), and explain the role they play in the imputation of missing values, and in enabling robust decompositions of the measured values into a seasonal component, a possible climate signal, and a station-specific remainder. The methods for change-point detection that we describe include statistical process control, wavelet multi-resolution analysis, adaptive weights smoothing, and a Bayesian procedure, all of which are applicable to single station records.

  16. Trend analysis and change point detection of annual and seasonal temperature series in Peninsular Malaysia

    NASA Astrophysics Data System (ADS)

    Suhaila, Jamaludin; Yusop, Zulkifli

    2017-06-01

    Most of the trend analysis that has been conducted has not considered the existence of a change point in the time series analysis. If these occurred, then the trend analysis will not be able to detect an obvious increasing or decreasing trend over certain parts of the time series. Furthermore, the lack of discussion on the possible factors that influenced either the decreasing or the increasing trend in the series needs to be addressed in any trend analysis. Hence, this study proposes to investigate the trends, and change point detection of mean, maximum and minimum temperature series, both annually and seasonally in Peninsular Malaysia and determine the possible factors that could contribute to the significance trends. In this study, Pettitt and sequential Mann-Kendall (SQ-MK) tests were used to examine the occurrence of any abrupt climate changes in the independent series. The analyses of the abrupt changes in temperature series suggested that most of the change points in Peninsular Malaysia were detected during the years 1996, 1997 and 1998. These detection points captured by Pettitt and SQ-MK tests are possibly related to climatic factors, such as El Niño and La Niña events. The findings also showed that the majority of the significant change points that exist in the series are related to the significant trend of the stations. Significant increasing trends of annual and seasonal mean, maximum and minimum temperatures in Peninsular Malaysia were found with a range of 2-5 °C/100 years during the last 32 years. It was observed that the magnitudes of the increasing trend in minimum temperatures were larger than the maximum temperatures for most of the studied stations, particularly at the urban stations. These increases are suspected to be linked with the effect of urban heat island other than El Niño event.

  17. The Effect of Deposit Temperature on the Catalytic SO2-to-SO3 Conversion in a Copper Flash Smelting Heat Recovery Boiler

    NASA Astrophysics Data System (ADS)

    Lehmusto, Juho; Vainio, Emil; Laurén, Tor; Lindgren, Mari

    2018-02-01

    The aim of the work was to study the catalytic role of copper flash smelter deposit in the SO2-to-SO3 conversion. In addition, the effect of process gas temperature at 548 K to 1173 K (275 °C to 900 °C) on the amount of SO3 formed was addressed both in the absence and presence of genuine copper flash smelter deposit. The SO3 conversion rate changed as a function of process gas temperature, peaking at 1023 K (750 °C). A dramatic increase in the SO2-to-SO3 conversion was observed when process dust was present, clearly indicating that process dust catalyzes the SO2-to-SO3 conversion. Based on these results, the catalytic ability of the deposit may lead to sulfuric acid dew point corrosion.

  18. Temperature dependence of the interband critical points of bulk Ge and strained Ge on Si

    NASA Astrophysics Data System (ADS)

    Fernando, Nalin S.; Nunley, T. Nathan; Ghosh, Ayana; Nelson, Cayla M.; Cooke, Jacqueline A.; Medina, Amber A.; Zollner, Stefan; Xu, Chi; Menendez, Jose; Kouvetakis, John

    2017-11-01

    Epitaxial Ge layers on a Si substrate experience a tensile biaxial stress due to the difference between the thermal expansion coefficients of the Ge epilayer and the Si substrate, which can be measured using asymmetric X-ray diffraction reciprocal space maps. This stress depends on temperature and affects the band structure, interband critical points, and optical spectra. This manuscripts reports careful measurements of the temperature dependence of the dielectric function and the interband critical point parameters of bulk Ge and Ge epilayers on Si using spectroscopic ellipsometry from 80 to 780 K and from 0.8 to 6.5 eV. The authors find a temperature-dependent redshift of the E1 and E1 + Δ1 critical points in Ge on Si (relative to bulk Ge). This redshift can be described well with a model based on thermal expansion coefficients, continuum elasticity theory, and the deformation potential theory for interband transitions. The interband transitions leading to E0‧ and E2 critical points have lower symmetry and therefore are not affected by the stress.

  19. Change point detection of the Persian Gulf sea surface temperature

    NASA Astrophysics Data System (ADS)

    Shirvani, A.

    2017-01-01

    In this study, the Student's t parametric and Mann-Whitney nonparametric change point models (CPMs) were applied to detect change point in the annual Persian Gulf sea surface temperature anomalies (PGSSTA) time series for the period 1951-2013. The PGSSTA time series, which were serially correlated, were transformed to produce an uncorrelated pre-whitened time series. The pre-whitened PGSSTA time series were utilized as the input file of change point models. Both the applied parametric and nonparametric CPMs estimated the change point in the PGSSTA in 1992. The PGSSTA follow the normal distribution up to 1992 and thereafter, but with a different mean value after year 1992. The estimated slope of linear trend in PGSSTA time series for the period 1951-1992 was negative; however, that was positive after the detected change point. Unlike the PGSSTA, the applied CPMs suggested no change point in the Niño3.4SSTA time series.

  20. Liquid oxygen liquid acquisition device bubble point tests with high pressure lox at elevated temperatures

    NASA Astrophysics Data System (ADS)

    Jurns, J. M.; Hartwig, J. W.

    2012-04-01

    When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth's gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMDs) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122 K) as part of NASA's continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

  1. Liquid Oxygen Liquid Acquisition Device Bubble Point Tests with High Pressure LOX at Elevated Temperatures

    NASA Technical Reports Server (NTRS)

    Jurns, John M.; Hartwig, Jason W.

    2011-01-01

    When transferring propellant in space, it is most efficient to transfer single phase liquid from a propellant tank to an engine. In earth s gravity field or under acceleration, propellant transfer is fairly simple. However, in low gravity, withdrawing single-phase fluid becomes a challenge. A variety of propellant management devices (PMD) are used to ensure single-phase flow. One type of PMD, a liquid acquisition device (LAD) takes advantage of capillary flow and surface tension to acquire liquid. The present work reports on testing with liquid oxygen (LOX) at elevated pressures (and thus temperatures) (maximum pressure 1724 kPa and maximum temperature 122K) as part of NASA s continuing cryogenic LAD development program. These tests evaluate LAD performance for LOX stored in higher pressure vessels that may be used in propellant systems using pressure fed engines. Test data shows a significant drop in LAD bubble point values at higher liquid temperatures, consistent with lower liquid surface tension at those temperatures. Test data also indicates that there are no first order effects of helium solubility in LOX on LAD bubble point prediction. Test results here extend the range of data for LOX fluid conditions, and provide insight into factors affecting predicting LAD bubble point pressures.

  2. Migration of Point Defects in the Field of a Temperature Gradient

    NASA Astrophysics Data System (ADS)

    Kozlov, A. V.; Portnykh, I. A.; Pastukhov, V. I.

    2018-04-01

    The influence of the temperature gradient over the thickness of the cladding of a fuel element of a fast-neutron reactor on the migration of point defects formed in the cladding material due to neutron irradiation has been studied. It has been shown that, under the action of the temperature gradient, the flux of vacancies onto the inner surface of the cladding is higher than the flux of interstitial atoms, which leads to the formation of a specific concentration profile in the cladding with a vacancy-depleted zone near the inner surface. The experimental results on the spatial distribution of pores over the cladding thickness have been presented with which the data on the concentration profiles and vacancy fluxes have been compared.

  3. Temperature Regulation in Crewmembers After a 115-Day Space Flight

    NASA Technical Reports Server (NTRS)

    Lee, S. M. C.; Williams, W. J.; Siconolfi, S. F.; Gonzalez, R.; Greenleaf, J. E.; Mikhavlov, V.; Kobzev, Y.; Fortney, S. M.

    1996-01-01

    Impaired thermoregulation, which has been observed during exercise following bed rest, may significantly impact crewmembers during space flight operations by decreasing exercise capacity and orthostatic tolerance. Impaired temperature regulation would cause higher levels of core temperature, due to an attenuated cutaneous vasodilatory reflex and sweating response, for a given oxygen consumption. Two mate crewmembers of the Mir 18 mission performed supine cycle exercise se (20 min @ 40% and 20 min @ 65% preflight VO2pk) 145 days preflight and 5 days postflight. Core temperature (Tcore) was measured by an ingestible telemetry pill, skin blood flow (SBF) by laser Doppler velocimetry, and sweat rate (SR) by dew point hygrometry. Tcore at the time of test termination was similar (37.8 C) for both subjects before and after flight despite a shorter test duration (40 vs 28-29 minutes) postflight. The slopes of the SBF/Tcore relationship (Subj 1: 396 vs 214; Subj 2: 704 vs 143 Perfusion Unit/degC) and SR/Tcore relationship (Subj 1: 4.5 vs 2.1; Subj 2: 11.0 vs 3.6mg/min/sq cm/degC) were reduced postflight. Tcore thresholds for both SR (Subj 1: 37.4 vs 37.6; Subj 2: 37.6 vs 37.6 C) and SBF (Subj 1: 37.3 vs 37.5; Subj 2: 37.6 vs 37.7 C) were similar pre- to postflight. For these 2 crewmembers, it appeared that thermoregulation during exercise was impaired as evidenced by compromised heat loss responses after long-duration space flight.

  4. Super Clausius-Clapeyron scaling of extreme hourly precipitation and its relation to large-scale atmospheric conditions

    NASA Astrophysics Data System (ADS)

    Lenderink, Geert; Barbero, Renaud; Loriaux, Jessica; Fowler, Hayley

    2017-04-01

    Present-day precipitation-temperature scaling relations indicate that hourly precipitation extremes may have a response to warming exceeding the Clausius-Clapeyron (CC) relation; for The Netherlands the dependency on surface dew point temperature follows two times the CC relation corresponding to 14 % per degree. Our hypothesis - as supported by a simple physical argument presented here - is that this 2CC behaviour arises from the physics of convective clouds. So, we think that this response is due to local feedbacks related to the convective activity, while other large scale atmospheric forcing conditions remain similar except for the higher temperature (approximately uniform warming with height) and absolute humidity (corresponding to the assumption of unchanged relative humidity). To test this hypothesis, we analysed the large-scale atmospheric conditions accompanying summertime afternoon precipitation events using surface observations combined with a regional re-analysis for the data in The Netherlands. Events are precipitation measurements clustered in time and space derived from approximately 30 automatic weather stations. The hourly peak intensities of these events again reveal a 2CC scaling with the surface dew point temperature. The temperature excess of moist updrafts initialized at the surface and the maximum cloud depth are clear functions of surface dew point temperature, confirming the key role of surface humidity on convective activity. Almost no differences in relative humidity and the dry temperature lapse rate were found across the dew point temperature range, supporting our theory that 2CC scaling is mainly due to the response of convection to increases in near surface humidity, while other atmospheric conditions remain similar. Additionally, hourly precipitation extremes are on average accompanied by substantial large-scale upward motions and therefore large-scale moisture convergence, which appears to accelerate with surface dew point. This

  5. How Close Are We to the Temperature Tipping Point of the Biosphere?

    NASA Astrophysics Data System (ADS)

    Duffy, K. H.

    2017-12-01

    All biological processes accelerate rapidly with increasing temperature (Tinf); reaching a maximum rate (Tmax), after which they decline. However different biological processes may not be synchronised in their response to increasing temperatures resulting in major dis-equilibria of ecosystem processes. Particularly, the linked processes of photosynthesis and respiration have different curvature that is determined by their inherent sensitivity to temperature. Constraining the difference in temperature curves between photosynthesis and respiration allows us to quantify changes to global carbon metabolism and the land sink of carbon as a whole. During the last century the biosphere has acted as a sink of carbon from the atmosphere partly mitigating accumulation of CO2 derived from burning of fossil fuels Here we ask the following questions: As global temperature increases will photosynthesis and respiration become de-coupled and when? What is Tmax for the land sink, and where is current mean temperature range in regard to this important threshold? At what global and regional temperatures do we expect the biosphere to become a source of carbon to the atmosphere? To address these questions we used the recently released FLUXNET2015 dataset comprised of 212 eddy covariance flux tower sites which concurrently measure land-atmosphere carbon exchange along with micro-meteorological variables. Here, we illustrate our results for Tinf and Tmax of the land sink by biome and for the biosphere as a whole. Our results suggest that recent warming has already pushed us past the inflection point of photosynthesis, and that any additional warming will increase the cumulative annual dose of time spent past Tmax for the land sink. Even under moderate climate projections, we expect to see a slowing of the terrestrial carbon sink by as early as 2040.

  6. Is oral temperature an accurate measurement of deep body temperature? A systematic review.

    PubMed

    Mazerolle, Stephanie M; Ganio, Matthew S; Casa, Douglas J; Vingren, Jakob; Klau, Jennifer

    2011-01-01

    Oral temperature might not be a valid method to assess core body temperature. However, many clinicians, including athletic trainers, use it rather than criterion standard methods, such as rectal thermometry. To critically evaluate original research addressing the validity of using oral temperature as a measurement of core body temperature during periods of rest and changing core temperature. In July 2010, we searched the electronic databases PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), SPORTDiscus, Academic Search Premier, and the Cochrane Library for the following concepts: core body temperature, oral, and thermometers. Controlled vocabulary was used, when available, as well as key words and variations of those key words. The search was limited to articles focusing on temperature readings and studies involving human participants. Original research was reviewed using the Physiotherapy Evidence Database (PEDro). Sixteen studies met the inclusion criteria and subsequently were evaluated by 2 independent reviewers. All 16 were included in the review because they met the minimal PEDro score of 4 points (of 10 possible points), with all but 2 scoring 5 points. A critical review of these studies indicated a disparity between oral and criterion standard temperature methods (eg, rectal and esophageal) specifically as the temperature increased. The difference was -0.50°C ± 0.31°C at rest and -0.58°C ± 0.75°C during a nonsteady state. Evidence suggests that, regardless of whether the assessment is recorded at rest or during periods of changing core temperature, oral temperature is an unsuitable diagnostic tool for determining body temperature because many measures demonstrated differences greater than the predetermined validity threshold of 0.27°C (0.5°F). In addition, the differences were greatest at the highest rectal temperatures. Oral temperature cannot accurately reflect core body temperature, probably because it is

  7. Temperature-driven evolution of critical points, interlayer coupling, and layer polarization in bilayer Mo S2

    NASA Astrophysics Data System (ADS)

    Du, Luojun; Zhang, Tingting; Liao, Mengzhou; Liu, Guibin; Wang, Shuopei; He, Rui; Ye, Zhipeng; Yu, Hua; Yang, Rong; Shi, Dongxia; Yao, Yugui; Zhang, Guangyu

    2018-04-01

    The recently emerging two-dimensional (2D) transition-metal dichalcogenides (TMDCs) have been a fertile ground for exploring abundant exotic physical properties. Critical points, the extrema or saddle points of electronic bands, are the cornerstone of condensed-matter physics and fundamentally determine the optical and transport phenomena of the TMDCs. However, for bilayer Mo S2 , a typical TMDC and the unprecedented electrically tunable venue for valleytronics, there has been a considerable controversy on its intrinsic electronic structure, especially for the conduction band-edge locations. Moreover, interlayer hopping and layer polarization in bilayer Mo S2 which play vital roles in valley-spintronic applications have remained experimentally elusive. Here, we report the experimental observation of intrinsic critical points locations, interlayer hopping, layer-spin polarization, and their evolution with temperature in bilayer Mo S2 by performing temperature-dependent photoluminescence. Our measurements confirm that the conduction-band minimum locates at the Kc instead of Qc, and the energy splitting between Qc and Kc redshifts with a descent of temperature. Furthermore, the interlayer hopping energy for holes and temperature-dependent layer polarization are quantitatively determined. Our observations are in good harmony with density-functional theory calculations.

  8. Effects of sand burial on dew deposition on moss soil crust in a revegetated area of the Tennger Desert, Northern China

    NASA Astrophysics Data System (ADS)

    Jia, Rong-liang; Li, Xin-rong; Liu, Li-chao; Pan, Yan-xia; Gao, Yan-hong; Wei, Yong-ping

    2014-11-01

    Sand burial and dew deposition are two fundamental phenomena profoundly influencing biological soil crusts in desert areas. However, little information is available regarding the effects of sand burial on dew deposition on biological soil crusts in desert ecosystems. In this study, we evaluated the effects of sand burial at depths of 0 (control), 0.5, 1, 2 and 4 mm on dew formation and evaporation of three dominant moss crusts in a revegetated area of the Tengger Desert (Northern China) in 2010. The results revealed that sand burial significantly decreased the amount of dew deposited on the three moss crust types by acting as a semi-insulator retarding the dew formation and evaporation rates. The changes in surface temperature cannot fully explain the variations of the formation and evaporation rates of dew by moss crusts buried by sand. The extension of dew retention time was reflected by the higher dew ratios (the ratio of dew amount at a certain time to the maximum value in a daily course) in the daytime, and may to some extent have acted as compensatory mechanisms that diminished the negative effects of the reduction of dew amount induced by sand burial of moss crusts. The resistances to reduction of dewfall caused by sand burial among the three moss crusts were also compared and it was found that Bryum argenteum crust showed the highest tolerance, followed by crusts dominated by Didymodon vinealis and Syntrichia caninervis. This sequence corresponds well with the successional order of the three moss crusts in the revegetated area, thereby suggesting that resistance to reduction of dewfall may act as one mechanism by which sand burial drives the succession of moss crusts in desert ecosystems. This side effect of dew reduction induced by sand burial on biological soil crusts should be considered in future ecosystem construction and management of desert area.

  9. Temperature and Species Measurements of Combustion Produced by a 9-Point Lean Direct Injector

    NASA Technical Reports Server (NTRS)

    Tedder, Sarah A.; Hicks, Yolanda R.; Locke, Randy J.

    2013-01-01

    This paper presents measurements of temperature and relative species concentrations in the combustion flowfield of a 9-point swirl venturi lean direct injector fueled with JP-8. The temperature and relative species concentrations of the flame produced by the injector were measured using spontaneous Raman scattering (SRS). Results of measurements taken at four flame conditions are presented. The species concentrations reported are measured relative to nitrogen and include oxygen, carbon dioxide, and water.

  10. Extreme precipitation response to climate perturbations in an atmospheric mesoscale model

    NASA Astrophysics Data System (ADS)

    Attema, Jisk J.; Loriaux, Jessica M.; Lenderink, Geert

    2014-01-01

    Observations of extreme (sub-)hourly precipitation at mid-latitudes show a large dependency on the dew point temperature often close to 14% per degree—2 times the dependency of the specific humidity on dew point temperature which is given by the Clausius-Clapeyron (CC) relation. By simulating a selection of 11 cases over the Netherlands characterized by intense showers, we investigate this behavior in the non-hydrostatic weather prediction model Harmonie at a resolution of 2.5 km. These experiments are repeated using perturbations of the atmospheric profiles of temperature and humidity: (i) using an idealized approach with a 2° warmer (colder) atmosphere assuming constant relative humidity, and (ii) using changes in temperature and humidity derived from a long climate change simulation at 2° global warming. All perturbations have a difference in the local dew point temperature compared to the reference of approximately 2°. Differences are considerable between the cases, with dependencies ranging from almost zero to an increase of 18% per degree rise of the dew point temperature. On average however, we find an increase of extreme precipitation intensity of 11% per degree for the idealized perturbation, and 9% per degree for the climate change perturbation. For the most extreme events these dependencies appear to approach a rate of 11-14% per degree, in closer agreement with the observed relation.

  11. A miniature high-temperature fixed point for self-validation of type C thermocouples

    NASA Astrophysics Data System (ADS)

    Ongrai, O.; Pearce, J. V.; Machin, G.; Sweeney, S. J.

    2011-10-01

    Reliable high-temperature (>1500 °C) measurement is crucial for a wide range of industrial processes as well as specialized applications, e.g. aerospace. The most common type of sensor used for high-temperature measurement is the thermocouple. At and above 1500 °C, tungsten-rhenium (W-Re) thermocouples are the most commonly used temperature sensors due to their utility up to 2300 °C. However, the achievable accuracy of W-Re thermocouples is seriously limited by the effects of their inhomogeneity, drift and hysteresis. Furthermore, due to their embrittlement at high temperature, the removal of these thermocouples from environments such as nuclear power plants or materials processing furnaces for recalibration is generally not possible. Even if removal for recalibration were possible, this would be of, at best, very limited use due to large inhomogeneity effects. Ideally, these thermocouples require some mechanism to monitor their drift in situ. In this study, we describe a miniature Co-C eutectic fixed-point cell to evaluate the stability of type C (W5%Re/W26%Re) thermocouples by means of in situ calibration.

  12. The gallium melting-point standard: its application and evaluation for temperature measurements in the clinical laboratory.

    PubMed

    Bowers, G N; Inman, S R

    1977-01-01

    We are impressed with the ease and certainty of calibration electronic thermometers with thermistor probes to +/- 0.01 degree C at the gallium melting point, 29.771(4) degrees C. The IFCC reference method for measuring aspartate aminotransferase activity in serum was run at the reaction temperature of 29.771(4) degrees C. By constantly referencing to gallium as an integral part of the assay procedure, we determined the absolute reaction temperature to IPTS-68 (International Practical Temperature Scale of 1968) to +/- 0.02 degrees C. This unique temperature calibration standard near the center of the range of temperatures commonly used in the clinical laboratory is a valuable addition and can be expected to improve the accuracy of measurements, especially in clinical enzymology.

  13. Water potential in excised leaf tissue. Comparison of a commercial dew point hygrometer and a thermocouple psychrometer on soybean, wheat, and barley

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nelsen, C.E.; Safir, G.R.; Hanson, A.D.

    1978-01-01

    Leaf water potential (Psi/sub leaf/) determinations were made on excised leaf samples using a commercial dew point hygrometer (Wescor Inc., Logan, Utah) and a thermocouple psychrometer operated in the isopiestic mode. With soybean leaves (Glycine max L.), there was good agreement between instruments; equilibration times were 2 to 3 hours. With cereals (Triticum aestivum L. and Hordeum vulgare L.), agreement between instruments was poor for moderately wilted leaves when 7-mm-diameter punches were used in the hygrometer and 20-mm slices were used in the psychrometer, because the Psi/sub leaf/ values from the dew point hygrometer were too high. Agreement was improvedmore » by replacing the 7-mm punch samples in the hygrometer by 13-mm slices, which had a lower cut edge to volume ratio. Equilibration times for cereals were normally 6 to 8 hours. Spuriously high Psi/sub leaf/ values obtained with 7-mm leaf punches may be associated with the ion release and reabsorption that occur upon tissue excision; such errors evidently depend both on the species and on tissue water status.« less

  14. Water potential in excised leaf tissue: comparison of a commercial dew point hygrometer and a thermocouple psychrometer on soybean, wheat, and barley.

    PubMed

    Nelsen, C E; Safir, G R; Hanson, A D

    1978-01-01

    Leaf water potential (Psi(leaf)) determinations were made on excised leaf samples using a commercial dew point hygrometer (Wescor Inc., Logan, Utah) and a thermocouple psychrometer operated in the isopiestic mode. With soybean leaves (Glycine max L.), there was good agreement between instruments; equilibration times were 2 to 3 hours. With cereals (Triticum aestivum L. and Hordeum vulgare L.), agreement between instruments was poor for moderately wilted leaves when 7-mm-diameter punches were used in the hygrometer and 20-mm slices were used in the psychrometer, because the Psi(leaf) values from the dew point hygrometer were too high. Agreement was improved by replacing the 7-mm punch samples in the hygrometer by 13-mm slices, which had a lower cut edge to volume ratio. Equilibration times for cereals were normally 6 to 8 hours. Spuriously high Psi(leaf) values obtained with 7-mm leaf punches may be associated with the ion release and reabsorption that occur upon tissue excision; such errors evidently depend both on the species and on tissue water status.

  15. Freezing temperature of finger skin.

    PubMed

    Wilson, O; Goldman, R F; Molnar, G W

    1976-10-01

    In 45 subjects, 154 frostnips of the finger were induced by cooling in air at -15 degrees C with various wind speeds. The mean supercooled skin temperature at which frostnip appeared was -9.4 degrees C. The mean skin temperature rise due to heat of fusion at ice crystallization was 5.3 degrees C. The skin temperature rose to what was termed the apparent freezing point. The relation of this point to the supercooled skin temperature was analyzed for the three wind speeds used. An apparent freezing point for a condition of no supercooling was calculated, estimating the highest temperature at which skin freezes at a given wind speed. The validity of the obtained differences in apparent freezing point was tested by an analysis of covariance. Although not statistically significant, the data suggest that the apparent freezing point with no supercooling decreases with increasing wind velocity. The highest calculated apparent freezing point at -15 degrees C and 6.8 m/s was 1.2 degrees C lower than the true freezing point for skin previously determined in brine, which is a statistically significant difference.

  16. Is Oral Temperature an Accurate Measurement of Deep Body Temperature? A Systematic Review

    PubMed Central

    Mazerolle, Stephanie M.; Ganio, Matthew S.; Casa, Douglas J.; Vingren, Jakob; Klau, Jennifer

    2011-01-01

    Context: Oral temperature might not be a valid method to assess core body temperature. However, many clinicians, including athletic trainers, use it rather than criterion standard methods, such as rectal thermometry. Objective: To critically evaluate original research addressing the validity of using oral temperature as a measurement of core body temperature during periods of rest and changing core temperature. Data Sources: In July 2010, we searched the electronic databases PubMed, Scopus, Cumulative Index to Nursing and Allied Health Literature (CINAHL), SPORTDiscus, Academic Search Premier, and the Cochrane Library for the following concepts: core body temperature, oral, and thermometers. Controlled vocabulary was used, when available, as well as key words and variations of those key words. The search was limited to articles focusing on temperature readings and studies involving human participants. Data Synthesis: Original research was reviewed using the Physiotherapy Evidence Database (PEDro). Sixteen studies met the inclusion criteria and subsequently were evaluated by 2 independent reviewers. All 16 were included in the review because they met the minimal PEDro score of 4 points (of 10 possible points), with all but 2 scoring 5 points. A critical review of these studies indicated a disparity between oral and criterion standard temperature methods (eg, rectal and esophageal) specifically as the temperature increased. The difference was −0.50°C ± 0.31°C at rest and −0.58°C ± 0.75°C during a nonsteady state. Conclusions: Evidence suggests that, regardless of whether the assessment is recorded at rest or during periods of changing core temperature, oral temperature is an unsuitable diagnostic tool for determining body temperature because many measures demonstrated differences greater than the predetermined validity threshold of 0.27°C (0.5°F). In addition, the differences were greatest at the highest rectal temperatures. Oral temperature cannot

  17. Automated measurement of cattle surface temperature and its correlation with rectal temperature

    PubMed Central

    Ren, Kang; Chen, XiaoLi; Lu, YongQiang; Wang, Dong

    2017-01-01

    The body temperature of cattle varies regularly with both the reproductive cycle and disease status. Establishing an automatic method for monitoring body temperature may facilitate better management of reproduction and disease control in cattle. Here, we developed an Automatic Measurement System for Cattle’s Surface Temperature (AMSCST) to measure the temperature of metatarsus by attaching a special shell designed to fit the anatomy of cattle’s hind leg. Using AMSCST, the surface temperature (ST) on the metatarsus of the hind leg was successively measured during 24 hours a day with an interval of one hour in three tested seasons. Based on ST and rectal temperature (RT) detected by AMSCST and mercury thermometer, respectively, a linear mixed model was established, regarding both the time point and seasonal factors as the fixed effects. Unary linear correlation and Bland-Altman analysis results indicated that the temperatures measured by AMSCST were closely correlated to those measured by mercury thermometer (R2 = 0.998), suggesting that the AMSCST is an accurate and reliable way to detect cattle’s body temperature. Statistical analysis showed that the differences of STs among the three seasons, or among the different time points were significant (P<0.05), and the differences of RTs among the different time points were similarly significant (P<0.05). The prediction accuracy of the mixed model was verified by 10-fold cross validation. The average difference between measured RT and predicted RT was about 0.10 ± 0.10°C with the association coefficient of 0.644, indicating the feasibility of this model in measuring cattle body temperature. Therefore, an automated technology for accurately measuring cattle body temperature was accomplished by inventing an optimal device and establishing the AMSCST system. PMID:28426682

  18. Nutrition content of brisket point end of part Simental Ongole Crossbred meat in boiled various temperature

    NASA Astrophysics Data System (ADS)

    Riyanto, J.; Sudibya; Cahyadi, M.; Aji, A. P.

    2018-01-01

    This aim of this study was to determine the quality of nutritional contents of beef brisket point end of Simental Ongole Crossbred meat in various boiling temperatures. Simental Ongole Crossbred had been fattened for 9 months. Furthermore, they were slaughtered at slaughterhouse and brisket point end part of meat had been prepared to analyse its nutritional contents using Food Scan. These samples were then boiled at 100°C for 0 (TR), 15 (R15), and 30 (R30) minutes, respectively. The data was analysed using Randomized Complete Design (CRD) and Duncan’s multiple range test (DMRT) had been conducted to differentiate among three treatments. The results showed that boiling temperatures significantly affected moisture, and cholesterol contents of beef (P<0.05) while fat content was not significantly affected by boiling temperatures. The boiling temperature decreased beef water contents from 72.77 to 70.84%, on the other hand, the treatment increased beef protein and cholesterol contents from 20.77 to 25.14% and 47.55 to 50.45 mg/100g samples, respectively. The conclusion of this study was boiling of beef at 100°C for 15 minutes and 30 minutes decreasing water content and increasing protein and cholesterol contents of brisket point end of Simental Ongole Crossbred beef.

  19. Recording dew gage

    Treesearch

    Merle G. Lloyd

    1963-01-01

    The instrument developed by Intermountain Forest and Range Experiment Station to record duration and amount of dew (fig. 1) consists of an expanded polystyrene block mounted on a balance, a clock-driven drum, and a pen geared from the balance to the drum. Changes in weight of the expanded polystyrene block as dew or rain is deposited are recorded on a chart mounted on...

  20. Land Surface Temperature Measurements form EOS MODIS Data

    NASA Technical Reports Server (NTRS)

    Wan, Zhengming

    1996-01-01

    We have developed a physics-based land-surface temperature (LST) algorithm for simultaneously retrieving surface band-averaged emissivities and temperatures from day/night pairs of MODIS (Moderate Resolution Imaging Spectroradiometer) data in seven thermal infrared bands. The set of 14 nonlinear equations in the algorithm is solved with the statistical regression method and the least-squares fit method. This new LST algorithm was tested with simulated MODIS data for 80 sets of band-averaged emissivities calculated from published spectral data of terrestrial materials in wide ranges of atmospheric and surface temperature conditions. Comprehensive sensitivity and error analysis has been made to evaluate the performance of the new LST algorithm and its dependence on variations in surface emissivity and temperature, upon atmospheric conditions, as well as the noise-equivalent temperature difference (NE(Delta)T) and calibration accuracy specifications of the MODIS instrument. In cases with a systematic calibration error of 0.5%, the standard deviations of errors in retrieved surface daytime and nighttime temperatures fall between 0.4-0.5 K over a wide range of surface temperatures for mid-latitude summer conditions. The standard deviations of errors in retrieved emissivities in bands 31 and 32 (in the 10-12.5 micrometer IR spectral window region) are 0.009, and the maximum error in retrieved LST values falls between 2-3 K. Several issues related to the day/night LST algorithm (uncertainties in the day/night registration and in surface emissivity changes caused by dew occurrence, and the cloud cover) have been investigated. The LST algorithms have been validated with MODIS Airborne Simulator (MAS) dada and ground-based measurement data in two field campaigns conducted in Railroad Valley playa, NV in 1995 and 1996. The MODIS LST version 1 software has been delivered.

  1. Analysis of a resistance-energy balance method for estimating daily evaporation from wheat plots using one-time-of-day infrared temperature observations

    NASA Technical Reports Server (NTRS)

    Choudhury, B. J.; Idso, S. B.; Reginato, R. J.

    1986-01-01

    Accurate estimates of evaporation over field-scale or larger areas are needed in hydrologic studies, irrigation scheduling, and meteorology. Remotely sensed surface temperature might be used in a model to calculate evaporation. A resistance-energy balance model, which combines an energy balance equation, the Penman-Monteith (1981) evaporation equation, and van den Honert's (1948) equation for water extraction by plant roots, is analyzed for estimating daily evaporation from wheat using postnoon canopy temperature measurements. Additional data requirements are half-hourly averages of solar radiation, air and dew point temperatures, and wind speed, along with reasonable estimates of canopy emissivity, albedo, height, and leaf area index. Evaporation fluxes were measured in the field by precision weighing lysimeters for well-watered and water-stressed wheat. Errors in computed daily evaporation were generally less than 10 percent, while errors in cumulative evaporation for 10 clear sky days were less than 5 percent for both well-watered and water-stressed wheat. Some results from sensitivity analysis of the model are also given.

  2. Searching for the best modeling specification for assessing the effects of temperature and humidity on health: a time series analysis in three European cities.

    PubMed

    Rodopoulou, Sophia; Samoli, Evangelia; Analitis, Antonis; Atkinson, Richard W; de'Donato, Francesca K; Katsouyanni, Klea

    2015-11-01

    Epidemiological time series studies suggest daily temperature and humidity are associated with adverse health effects including increased mortality and hospital admissions. However, there is no consensus over which metric or lag best describes the relationships. We investigated which temperature and humidity model specification most adequately predicted mortality in three large European cities. Daily counts of all-cause mortality, minimum, maximum and mean temperature and relative humidity and apparent temperature (a composite measure of ambient and dew point temperature) were assembled for Athens, London, and Rome for 6 years between 1999 and 2005. City-specific Poisson regression models were fitted separately for warm (April-September) and cold (October-March) periods adjusting for seasonality, air pollution, and public holidays. We investigated goodness of model fit for each metric for delayed effects up to 13 days using three model fit criteria: sum of the partial autocorrelation function, AIC, and GCV. No uniformly best index for all cities and seasonal periods was observed. The effects of temperature were uniformly shown to be more prolonged during cold periods and the majority of models suggested separate temperature and humidity variables performed better than apparent temperature in predicting mortality. Our study suggests that the nature of the effects of temperature and humidity on mortality vary between cities for unknown reasons which require further investigation but may relate to city-specific population, socioeconomic, and environmental characteristics. This may have consequences on epidemiological studies and local temperature-related warning systems.

  3. Searching for the best modeling specification for assessing the effects of temperature and humidity on health: a time series analysis in three European cities

    NASA Astrophysics Data System (ADS)

    Rodopoulou, Sophia; Samoli, Evangelia; Analitis, Antonis; Atkinson, Richard W.; de'Donato, Francesca K.; Katsouyanni, Klea

    2015-11-01

    Epidemiological time series studies suggest daily temperature and humidity are associated with adverse health effects including increased mortality and hospital admissions. However, there is no consensus over which metric or lag best describes the relationships. We investigated which temperature and humidity model specification most adequately predicted mortality in three large European cities. Daily counts of all-cause mortality, minimum, maximum and mean temperature and relative humidity and apparent temperature (a composite measure of ambient and dew point temperature) were assembled for Athens, London, and Rome for 6 years between 1999 and 2005. City-specific Poisson regression models were fitted separately for warm (April-September) and cold (October-March) periods adjusting for seasonality, air pollution, and public holidays. We investigated goodness of model fit for each metric for delayed effects up to 13 days using three model fit criteria: sum of the partial autocorrelation function, AIC, and GCV. No uniformly best index for all cities and seasonal periods was observed. The effects of temperature were uniformly shown to be more prolonged during cold periods and the majority of models suggested separate temperature and humidity variables performed better than apparent temperature in predicting mortality. Our study suggests that the nature of the effects of temperature and humidity on mortality vary between cities for unknown reasons which require further investigation but may relate to city-specific population, socioeconomic, and environmental characteristics. This may have consequences on epidemiological studies and local temperature-related warning systems.

  4. Chemical composition of dew in Amman, Jordan

    NASA Astrophysics Data System (ADS)

    Jiries, Anwar

    Twenty-six dew samples were collected on a glass surface from an urbanized area in Amman city during the period October 1999 to June 2000. They were analyzed for the major ions (Cl, SO 4, NO 3, Ca, Mg, Na, K and NH 4) in addition to three heavy metals (Pb, Cd and Co). Rain samples were collected for the same period and compared to the chemical constituents of dew. It was found that both rain and dew samples were of almost neutral acidity due to the buffering effect of CaCO 3. Dew composition was mainly from CaSO 4 solution due to conversion of CaCO 3 to CaSO 4 when left exposed to a sulfate-rich atmosphere. The total dissolved solids were higher in dew than rain samples of the same period. This was attributed to higher evaporation effect on dew than rain. The heavy metal content in dew is highest during the cold winter season (December-March) due to excess fossil fuel combustion for heating purposes in this period. The heavy metal content in dew was lower than that for rain during the same period because of the shorter period of dew formation than rainwater.

  5. Indirect determination of the thermodynamic temperature of the copper point by a multi-fixed-point technique

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Florio, M.; Girard, F.

    2010-06-01

    An indirect determination of the thermodynamic temperature of the fixed point of copper was made at INRIM by measuring four cells with a Si-based and an InGaAs-based precision radiation thermometer carrying approximated thermodynamic scales realized up to the Ag point. An average value TCu = 1357.840 K was found with a standard uncertainty of 0.047 K. A consequent (T - T90)Cu value of 70 mK can be derived which is 18 mK higher than, but consistent with, the presently available (T - T90)Cu as elaborated by the CCT-WG4.

  6. The change of steel surface chemistry regarding oxygen partial pressure and dew point

    NASA Astrophysics Data System (ADS)

    Norden, Martin; Blumenau, Marc; Wuttke, Thiemo; Peters, Klaus-Josef

    2013-04-01

    By investigating the surface state of a Ti-IF, TiNb-IF and a MnCr-DP after several series of intercritical annealing, the impact of the annealing gas composition on the selective oxidation process is discussed. On behalf of the presented results, it can be concluded that not the general oxygen partial pressure in the annealing furnace, which is a result of the equilibrium reaction of water and hydrogen, is the main driving force for the selective oxidation process. It is shown that the amounts of adsorbed gases at the strip surface and the effective oxygen partial pressure resulting from the adsorbed gases, which is mainly dependent on the water content of the annealing furnace, is driving the selective oxidation processes occurring during intercritical annealing. Thus it is concluded, that for industrial applications the dew point must be the key parameter value for process control.

  7. Elevated temperature and temperature programming in conventional liquid chromatography--fundamentals and applications.

    PubMed

    Vanhoenacker, Gerd; Sandra, Pat

    2006-08-01

    Temperature, as a powerful variable in conventional LC is discussed from a fundamental point of view and illustrated with applications from the author's laboratory. Emphasis is given to the influence of temperature on speed, selectivity, efficiency, detectability, and mobile phase composition (green chromatography). The problems accompanying the use of elevated temperature and temperature programming in LC are reviewed and solutions are described. The available stationary phases for high temperature operation are summarized and a brief overview of recent applications reported in the literature is given.

  8. An updated global grid point surface air temperature anomaly data set: 1851--1990

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sepanski, R.J.; Boden, T.A.; Daniels, R.C.

    1991-10-01

    This document presents land-based monthly surface air temperature anomalies (departures from a 1951--1970 reference period mean) on a 5{degree} latitude by 10{degree} longitude global grid. Monthly surface air temperature anomalies (departures from a 1957--1975 reference period mean) for the Antarctic (grid points from 65{degree}S to 85{degree}S) are presented in a similar way as a separate data set. The data were derived primarily from the World Weather Records and the archives of the United Kingdom Meteorological Office. This long-term record of temperature anomalies may be used in studies addressing possible greenhouse-gas-induced climate changes. To date, the data have been employed inmore » generating regional, hemispheric, and global time series for determining whether recent (i.e., post-1900) warming trends have taken place. This document also presents the monthly mean temperature records for the individual stations that were used to generate the set of gridded anomalies. The periods of record vary by station. Northern Hemisphere station data have been corrected for inhomogeneities, while Southern Hemisphere data are presented in uncorrected form. 14 refs., 11 figs., 10 tabs.« less

  9. Low temperature binary gas mixtures

    NASA Astrophysics Data System (ADS)

    McIntosh, Glen E.; Leonard, Kenneth R.

    2017-12-01

    Application of partial pressure technology to combinations of one gas above its critical temperature (helium) mixed with a two-phase liquid (nitrogen) can result in liquid temperatures down to and below the nitrogen triple point. The thermodynamics of this process is developed and an experimental apparatus is described which was used to produce a helium/nitrogen bath temperature of 59.17 K, 4 K lower than the 63.2 K nitrogen triple point and lower than any liquid nitrogen temperature reported in the literature.

  10. Comparison of effects of elevated temperature versus temperature fluctuations on reef corals at Kahe Point, Oahu

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Coles, S.L.

    1975-01-01

    Bottom temperature and the condition of live corals in the vicinity of the discharge plume from the Hawaiian Electric Company Kahe Generating Station, Oahu, Hawaii, were monitored August--December 1973. Mortality to Pocillopora meandrina, the most thermally sensitive species of the area, was no greater under the conditions of maximum thermal enrichment near the living reef fringe in the discharge area (1--2 m depth) than in an area (4--5 m depth) more distant from the discharge. Sublethal coral damage was more pronounced near the discharge, but was mostly limited to loss of zooxanthellar pigment which was restored following yearly ambient temperaturemore » maxima. Although bottom temperatures in the discharge area continually varied 3$sup 0$--4$sup 0$C within minute periods during every low tide, live corals seldom encountered temperatures exceeding 31$sup 0$C. The limited damage that occurred to live corals indicates that upper absolute temperatures are more critical in producing coral damage than are short- term temperature shocks near upper lethal limits. (auth)« less

  11. The effect of substrate properties, size, position, sheltering and shading on dew: An experimental approach in the Negev Desert

    NASA Astrophysics Data System (ADS)

    Kidron, Giora J.

    2010-11-01

    Affected by the interrelationships between the air mass and the substrate properties, dew measurements entail numerous difficulties. Inattentiveness to the complexities involved may result in inconsistent and consequently unreliable data and thus in misleading conclusions. This is especially important in dew deserts such as the Negev where dew may be regarded as an important water source. In an attempt to highlight some of the factors that may affect dew condensation, an experimental approach was adapted during which dew condensation at different surfaces (smooth and ragged Plexiglas, bright limestone and dark flint cobbles), at various size substrata with identical axes (of 2.5, 5, 10, 20, 30 and 40 cm) or different size axes (of 10 × 20, 10 × 30 and 10 × 40 cm), and substrata at different heights and settings was measured. Some of the settings explored were also sheltered by a shrub, a cave, an 80-cm-tall cliff and neighboring cobbles. No significant differences were found in the dew amounts condensing on the limestone and the flint cobbles. Smooth Plexiglas surfaces yielded significantly higher amounts than a ragged Plexiglas surface. As for the substratum height and size, the dew amounts increased with height (from 0.7 to 10.0 cm) and size (from 2.5 × 2.5 cm to 40 × 40 cm). However, an increase in the long axis (a-axis) to 20, 30 and 40 cm while leaving the b-axis constant (at 10 cm) resulted in only a slight increase in the dew amounts in comparison to a 10 × 10 cm substratum. While confined to non-sheltered habitats, dew at partially sheltered habitats (such as the margin of a shrub or a cave, the vicinity of a cliff and on 7-cm-high cobble surrounded by 15-cm-high cobbles) was significantly lower than at the exposed habitats. The differences in dew amounts coincided with minute differences in the surface temperatures, explained as resulting from differences in the outgoing nocturnal longwave radiational cooling. The findings may shed light on the dew

  12. Seasonal and temperature modifications of the association between fine particulate air pollution and cardiovascular hospitalization in New York state.

    PubMed

    Hsu, Wan-Hsiang; Hwang, Syni-An; Kinney, Patrick L; Lin, Shao

    2017-02-01

    It is known that extreme temperature and ambient air pollution are each independently associated with human health outcomes. However, findings from the few studies that have examined modified effects by seasons and the interaction between air pollution and temperature on health endpoints are inconsistent. This study examines the effects of short-term PM 2.5 (particulate matter less than or equal to 2.5μm in aerodynamic diameter) on hospitalization for cardiovascular diseases (CVDs), its modifications by season and temperature, and whether these effects are heterogeneous across different regions in New York State (NYS). We used daily average temperature and PM 2.5 concentrations as exposure indicators and performed a time series analysis with a quasi-Poisson model, controlling for possible confounders, such as time-relevant variables and dew point, for CVDs in NYS, 1991-2006. Stratification parametric models were applied to evaluate the modifying effects by seasons and temperature. Across the whole year, a 10-μg/m 3 increment in PM 2.5 concentration accounted for a 1.37% increase in CVDs (95% confidence interval (CI): 0.90%, 1.84%) in New York City, Long Island & Hudson. The PM 2.5 effect was strongest in winter, with an additional 2.06% (95% CI: 1.33%, 2.80%) increase in CVDs observed per 10-μg/m 3 increment in PM 2.5 . Temperature modified the PM 2.5 effects on CVDs, and these modifications by temperature on PM 2.5 effects on CVDs were found at low temperature days. These associations were heterogeneous across four PM 2.5 concentration regions. PM 2.5 was positively associated with CVD hospitalizations. The short-term PM 2.5 effect varied with season and temperature levels, and stronger effects were observed in winter and at low temperature days. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Wireless sensor network-based greenhouse environment monitoring and automatic control system for dew condensation prevention.

    PubMed

    Park, Dae-Heon; Park, Jang-Woo

    2011-01-01

    Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop's surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control.

  14. Temperature initiated passive cooling system

    DOEpatents

    Forsberg, C.W.

    1994-11-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature. 1 fig.

  15. Temperature initiated passive cooling system

    DOEpatents

    Forsberg, Charles W.

    1994-01-01

    A passive cooling system for cooling an enclosure only when the enclosure temperature exceeds a maximum standby temperature comprises a passive heat transfer loop containing heat transfer fluid having a particular thermodynamic critical point temperature just above the maximum standby temperature. An upper portion of the heat transfer loop is insulated to prevent two phase operation below the maximum standby temperature.

  16. Time series of canopy intercepted water and dew observed in a tropical tree plantation by means of microwave radiometry

    NASA Astrophysics Data System (ADS)

    Schneebeli, M.; Wolf, S.; Kunert, N.; Eugster, W.; Mätzler, C.

    2012-04-01

    During summer and autumn 2007, a 11 GHz microwave radiometer was deployed in an experimental tree plantation in Sardinilla, Panama. With this instrument, the opacity of the tree canopy was derived from incoming brightness temperatures received on the ground. A collocated eddy-covariance flux tower measured water vapor fluxes and meteorological variables above the canopy. It was found that canopy intercepted rain and dew formation modulated the diurnal opacity cycle. With an enhanced canopy opacity model accounting for water deposited on the leaves, we quantified the influence of canopy stored water (i.e. intercepted water and dew) on the opacity. With this technique it was possible to directly monitor high resolution time series of dew formation and rain interception during a period of two weeks. In contrast to through-fall measurements, this new technique allows to determine the amount of intercepted rain more precisely and during day and night since evaporation effects do not hamper the accuracy of the method. We found that during light rainfall up to 60% of the rain amount is intercepted by the canopy whereas during periods of intense rainfall, only 4% were intercepted. On average, about 15% of the rain amount was intercepted during rainfalls of medium intensities. By comparing the interception with the water vapor flux time series it was found that intercepted water is evaporated rapidly after it is deposited on the leaves, which resulted in an enhanced water vapor flux. Our study also provides the first direct measurements and quantifications of the temporal evolution of dew formation and evaporation in a tree canopy on a diurnal base. Dew accumulated during the night and until about 2 h after sunrise, when the water vapor flux began to exceed the dew formation rate. The dew continued to evaporate for another 3.5 h until the surface of the leaves was completely dry. On average, 0.17 mm of dew was formed during the night. Dew evaporation contributed 5% to the

  17. Modeling daily soil temperature over diverse climate conditions in Iran—a comparison of multiple linear regression and support vector regression techniques

    NASA Astrophysics Data System (ADS)

    Delbari, Masoomeh; Sharifazari, Salman; Mohammadi, Ehsan

    2018-02-01

    The knowledge of soil temperature at different depths is important for agricultural industry and for understanding climate change. The aim of this study is to evaluate the performance of a support vector regression (SVR)-based model in estimating daily soil temperature at 10, 30 and 100 cm depth at different climate conditions over Iran. The obtained results were compared to those obtained from a more classical multiple linear regression (MLR) model. The correlation sensitivity for the input combinations and periodicity effect were also investigated. Climatic data used as inputs to the models were minimum and maximum air temperature, solar radiation, relative humidity, dew point, and the atmospheric pressure (reduced to see level), collected from five synoptic stations Kerman, Ahvaz, Tabriz, Saghez, and Rasht located respectively in the hyper-arid, arid, semi-arid, Mediterranean, and hyper-humid climate conditions. According to the results, the performance of both MLR and SVR models was quite well at surface layer, i.e., 10-cm depth. However, SVR performed better than MLR in estimating soil temperature at deeper layers especially 100 cm depth. Moreover, both models performed better in humid climate condition than arid and hyper-arid areas. Further, adding a periodicity component into the modeling process considerably improved the models' performance especially in the case of SVR.

  18. Extrapolation of radiation thermometry scales for determining the transition temperature of metal-carbon points. Experiments with the Co-C

    NASA Astrophysics Data System (ADS)

    Battuello, M.; Girard, F.; Florio, M.

    2009-02-01

    Four independent radiation temperature scales approximating the ITS-90 at 900 nm, 950 nm and 1.6 µm have been realized from the indium point (429.7485 K) to the copper point (1357.77 K) which were used to derive by extrapolation the transition temperature T90(Co-C) of the cobalt-carbon eutectic fixed point. An INRIM cell was investigated and an average value T90(Co-C) = 1597.20 K was found with the four values lying within 0.25 K. Alternatively, thermodynamic approximated scales were realized by assigning to the fixed points the best presently available thermodynamic values and deriving T(Co-C). An average value of 1597.27 K was found (four values lying within 0.25 K). The standard uncertainties associated with T90(Co-C) and T(Co-C) were 0.16 K and 0.17 K, respectively. INRIM determinations are compatible with recent thermodynamic determinations on three different cells (values lying between 1597.11 K and 1597.25 K) and with the result of a comparison on the same cell by an absolute radiation thermometer and an irradiance measurement with filter radiometers which give values of 1597.11 K and 1597.43 K, respectively (Anhalt et al 2006 Metrologia 43 S78-83). The INRIM approach allows the determination of both ITS-90 and thermodynamic temperature of a fixed point in a simple way and can provide valuable support to absolute radiometric methods in defining the transition temperature of new high-temperature fixed points.

  19. Improvements in the realization of the ITS-90 over the temperature range from the melting point of gallium to the freezing point of silver at NIM

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sun, J.; Zhang, J. T.; Ping, Q.

    2013-09-11

    The temperature primary standard over the range from the melting point of gallium to the freezing point of silver in National institute of Metrology (NIM), China, was established in the early 1990s. The performance of all of fixed-point furnaces degraded and needs to be updated due to many years of use. Nowadays, the satisfactory fixed point materials can be available with the development of the modern purification techniques. NIM plans to use a group of three cells for each defining fixed point temperature. In this way the eventual drift of individual cells can be evidenced by periodic intercomparison and thismore » will increase the reliability in disseminating the ITS-90 in China. This article describes the recent improvements in realization of ITS-90 over temperature range from the melting point of gallium to the freezing point of silver at NIM. Taking advantages of the technological advances in the design and manufacture of furnaces, the new three-zone furnaces and the open-type fixed points were developed from the freezing point of indium to the freezing point of silver, and a furnace with the three-zone semiconductor cooling was designed to automatically realize the melting point of gallium. The reproducibility of the new melting point of gallium and the new open-type freezing points of In, Sn, Zn. Al and Ag is improved, especially the freezing points of Al and Ag with the reproducibility of 0.2mK and 0.5mK respectively. The expanded uncertainty in the realization of these defining fixed point temperatures is 0.34mK, 0.44mK, 0.54mK, 0.60mK, 1.30mK and 1.88mK respectively.« less

  20. 46 CFR 153.908 - Cargo viscosity and melting point information; measuring cargo temperature during discharge...

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 5 2014-10-01 2014-10-01 false Cargo viscosity and melting point information; measuring... Cargo viscosity and melting point information; measuring cargo temperature during discharge: Categories... lading, a written statement of the following: (1) For Category A or B NLS, the cargo's viscosity at 20 °C...

  1. 46 CFR 153.908 - Cargo viscosity and melting point information; measuring cargo temperature during discharge...

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 5 2013-10-01 2013-10-01 false Cargo viscosity and melting point information; measuring... Cargo viscosity and melting point information; measuring cargo temperature during discharge: Categories... lading, a written statement of the following: (1) For Category A or B NLS, the cargo's viscosity at 20 °C...

  2. 46 CFR 153.908 - Cargo viscosity and melting point information; measuring cargo temperature during discharge...

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 5 2012-10-01 2012-10-01 false Cargo viscosity and melting point information; measuring... Cargo viscosity and melting point information; measuring cargo temperature during discharge: Categories... lading, a written statement of the following: (1) For Category A or B NLS, the cargo's viscosity at 20 °C...

  3. Temperature Compensated Piezoelectric Materials

    DTIC Science & Technology

    1976-06-01

    and indicated no major phase changes between room temperature and the melting point of LijSiO-,. Various shielding — 1 .2- arrangements and...experiments. The DTA experiments showed a small endothermic peak at about 1030° and then the melting point at 1200oC. High temperature x-ray diffraction... melting point was lowered about 150° es* so that a boule could be grown without extraneous heat shields, but the boulep were still cracked. A thin

  4. Measuring Temperature Reading

    NASA Technical Reports Server (NTRS)

    2003-01-01

    There are two requirements for taking a measurement of something. The first is a tool for taking a measurement. The second is scale for making sense of the numbers of the measurement. For example, a ruler is often used to measure short lengths. It is the tool for measurement. On the ruler are one or more number scales with equally spaced numbers. These numbers can be compared with numbers from any other ruler that is accurately set to the same scale. Measuring length is far simpler than measuring temperature. While there is evidence of tools for measuring length at various times in human history, tools and scales for measuring temperature do not appear until more recent human history. Early thermometers, called thermoscopes, first appear in the 1500's. They were crude instruments that were not at all accurate. Most did not even have a number scale associated with them. This made them useless for most practical purposes. Gabriel Fahrenheit created the first accurate thermometer in 1714, and the Fahrenheit temperature scale followed it in 1724. The thermometer s accuracy was based on its use of mercury, a silver colored substance that remains liquid over a wide range of temperatures but expands or contracts in a standard, predictable way with changes in temperature. To set the scale, Fahrenheit created the coldest temperature that he could. He mixed equal parts of ice, water, and salt, and then used this as the zero point, 0 degrees, of his scale. He intended to make 30 degrees the freezing point of water and 90 degrees the temperature of the human body, but he had to later revise these temperatures to be 32 degrees and 96 degrees. In the final version of the scale, the temperature of the human body became 98.6 degrees. 19th century thermoscope

  5. Wireless Sensor Network-Based Greenhouse Environment Monitoring and Automatic Control System for Dew Condensation Prevention

    PubMed Central

    Park, Dae-Heon; Park, Jang-Woo

    2011-01-01

    Dew condensation on the leaf surface of greenhouse crops can promote diseases caused by fungus and bacteria, affecting the growth of the crops. In this paper, we present a WSN (Wireless Sensor Network)-based automatic monitoring system to prevent dew condensation in a greenhouse environment. The system is composed of sensor nodes for collecting data, base nodes for processing collected data, relay nodes for driving devices for adjusting the environment inside greenhouse and an environment server for data storage and processing. Using the Barenbrug formula for calculating the dew point on the leaves, this system is realized to prevent dew condensation phenomena on the crop’s surface acting as an important element for prevention of diseases infections. We also constructed a physical model resembling the typical greenhouse in order to verify the performance of our system with regard to dew condensation control. PMID:22163813

  6. [Comparison of ability to humidification of inspired air through the nose and oral cavity using dew point hygrometer].

    PubMed

    Paczesny, Daniel; Rapiejko, Piotr; Weremczuk, Jerzy; Jachowicz, Ryszard; Jurkiewicz, Dariusz

    2007-01-01

    Aim of this study was to check at the hospital the dew point hygrometer for fast measurement of air humidity in upper airways. The nose ability to humidification of inspired air and partially recover moisture from expired air was evaluated. Measurements from respiration through the nose and oral cavity were compared. The study was carried out in a group of 30 people (8 female and 22 male), age group 18 to 70 (mean age: 37 years old). In 22 of the participants there were no deviation from normal state in laryngologic examination, while in 4 participants nasal septum deviation without imaired nasal; oatency was found, in other 3--nasal vonchae hyperthrophy and in 1--nasal polips (grade I). The measurements of air humidity in upper air ways was done using specially designed and constructed measurement system. The air inspired through the nose and oral cavity is humidified. For typical external conditions (T = 22 degrees C i RH = 50%) the nose humidifies inspired air two times better then oral cavity (short time range of measurement approximately 1 min). Moisture from expired air through the nose is partially recovered (for patients with regular patency is 25% of the value of humidifying of inspired air). The oral cavity does not have ability to partially recovery moisture form expired air. The paper presented fast dew point hygrometer based on semiconductor microsystems for measurement humidity in inspired and expired air through the nose and oral cavity. Presented system can be a proper instrument for evaluation of nasal functions.

  7. Possible Role of Pectin-containing Mucilage and Dew in Repairing Embryo DNA of Seeds Adapted to Desert Conditions

    PubMed Central

    Huang, Zhenying; Boubriak, Ivan; Osborne, Daphne J.; Dong, Ming; Gutterman, Yitzchak

    2008-01-01

    Background and Aims Repair of damage to DNA of seed embryos sustained during long periods of quiescence under dry desert conditions is important for subsequent germination. The possibility that repair of embryo DNA can be facilitated by small amounts of water derived from dew temporarily captured at night by pectinaceous surface pellicles was tested. These pellicles are secreted during early seed development and form mucilage when hydrated. Methods Seeds of Artemisia sphaerocephala and Artemisia ordosica were collected from a sandy desert. Their embryos were damaged by gamma radiation to induce a standard level of DNA damage. The treated seeds were then exposed to nocturnal dew deposition on the surface of soil in the Negev desert highlands. The pellicles were removed from some seeds and left intact on others to test the ability of mucilage to support repair of the damaged DNA when night-time humidity and temperature favoured dew formation. Repair was assessed from fragmentation patterns of extracted DNA on agarose gels. Key Results For A. sphaerocephala, which has thick seed pellicles, DNA repair occurred in seeds with intact pellicles after 50 min of cumulative night dew formation, but not in seeds from which the pellicles had been removed. For A. ordosica, which has thin seed pellicles, DNA repair took at least 510 min of cumulative night dewing to achieve partial recovery of DNA integrity. The mucilage has the ability to rehydrate after daytime dehydration. Conclusions The ability of seeds to develop a mucilaginous layer when wetted by night-time dew, and to repair their DNA under these conditions, appear to be mechanisms that help maintain seed viability under harsh desert conditions. PMID:17495979

  8. Possible role of pectin-containing mucilage and dew in repairing embryo DNA of seeds adapted to desert conditions.

    PubMed

    Huang, Zhenying; Boubriak, Ivan; Osborne, Daphne J; Dong, Ming; Gutterman, Yitzchak

    2008-01-01

    Repair of damage to DNA of seed embryos sustained during long periods of quiescence under dry desert conditions is important for subsequent germination. The possibility that repair of embryo DNA can be facilitated by small amounts of water derived from dew temporarily captured at night by pectinaceous surface pellicles was tested. These pellicles are secreted during early seed development and form mucilage when hydrated. Seeds of Artemisia sphaerocephala and Artemisia ordosica were collected from a sandy desert. Their embryos were damaged by gamma radiation to induce a standard level of DNA damage. The treated seeds were then exposed to nocturnal dew deposition on the surface of soil in the Negev desert highlands. The pellicles were removed from some seeds and left intact on others to test the ability of mucilage to support repair of the damaged DNA when night-time humidity and temperature favoured dew formation. Repair was assessed from fragmentation patterns of extracted DNA on agarose gels. For A. sphaerocephala, which has thick seed pellicles, DNA repair occurred in seeds with intact pellicles after 50 min of cumulative night dew formation, but not in seeds from which the pellicles had been removed. For A. ordosica, which has thin seed pellicles, DNA repair took at least 510 min of cumulative night dewing to achieve partial recovery of DNA integrity. The mucilage has the ability to rehydrate after daytime dehydration. The ability of seeds to develop a mucilaginous layer when wetted by night-time dew, and to repair their DNA under these conditions, appear to be mechanisms that help maintain seed viability under harsh desert conditions.

  9. An Updated Global Grid Point Surface Air Temperature Anomaly Data Set: 1851-1990 (revised 1991) (NDP-020)

    DOE Data Explorer

    Jones, P. D. [University of East Anglia, Norwich, United Kingdom; Raper, S. C.B. [University of East Anglia, Norwich, United Kingdom; Cherry, B. S.G. [University of East Anglia, Norwich, United Kingdom; Goodess, C. M. [University of East Anglia, Norwich, United Kingdom; Wigley, T. M. L. [University of East Anglia, Norwich, United Kingdom; Santer, B. [University of East Anglia, Norwich, United Kingdom; Kelly, P. M. [University of East Anglia, Norwich, United Kingdom; Bradley, R. S. [University of Massachusetts, Amherst, Massachusetts (USA); Diaz, H. F. [National Oceanic and Atmospheric Administration (NOAA), Environmental Research Laboratories, Boulder, CO (United States).

    1991-01-01

    This NDP presents land-based monthly surface-air-temperature anomalies (departures from a 1951-1970 reference period mean) on a 5° latitude by 10° longitude global grid. Monthly surface-air-temperature anomalies (departures from a 1957-1975 reference period mean) for the Antarctic (grid points from 65°S to 85°S) are presented in a similar way as a separate data set. The data were derived primarily from the World Weather Records and from the archives of the United Kingdom Meteorological Office. This long-term record of temperature anomalies may be used in studies addressing possible greenhouse-gas-induced climate changes. To date, the data have been employed in producing regional, hemispheric, and global time series for determining whether recent (i.e., post-1900) warming trends have taken place. The present updated version of this data set is identical to the earlier version for all records from 1851-1978 except for the addition of the Antarctic surface-air-temperature anomalies beginning in 1957. Beginning with the 1979 data, this package differs from the earlier version in several ways. Erroneous data for some sites have been corrected after a review of the actual station temperature data, and inconsistencies in the representation of missing values have been removed. For some grid locations, data have been added from stations that had not contributed to the original set. Data from satellites have also been used to correct station records where large discrepancies were evident. The present package also extends the record by adding monthly surface-air-temperature anomalies for the Northern (grid points from 85°N to 0°) and Southern (grid points from 5°S to 60°S) Hemispheres for 1985-1990. In addition, this updated package presents the monthly-mean-temperature records for the individual stations that were used to produce the set of gridded anomalies. The periods of record vary by station. Northern Hemisphere data have been corrected for inhomogeneities

  10. FIRE_AX_UKMO_C130

    Atmospheric Science Data Center

    2015-11-25

    ... FSSP Gust Probe Hot-Wire Hygrometer Platinum Resistance PMS 2D-C Probe PRT-4 Pyranometer Pyrgeometer ... Parameters:  Barometric Altitude Cloud Top Temperature Deiced Temperature Dew/Frost Point Temperature Droplet ...

  11. Temperature-feedback upconversion nanocomposite for accurate photothermal therapy at facile temperature

    PubMed Central

    Zhu, Xingjun; Feng, Wei; Chang, Jian; Tan, Yan-Wen; Li, Jiachang; Chen, Min; Sun, Yun; Li, Fuyou

    2016-01-01

    Photothermal therapy (PTT) at present, following the temperature definition for conventional thermal therapy, usually keeps the temperature of lesions at 42–45 °C or even higher. Such high temperature kills cancer cells but also increases the damage of normal tissues near lesions through heat conduction and thus brings about more side effects and inhibits therapeutic accuracy. Here we use temperature-feedback upconversion nanoparticle combined with photothermal material for real-time monitoring of microscopic temperature in PTT. We observe that microscopic temperature of photothermal material upon illumination is high enough to kill cancer cells when the temperature of lesions is still low enough to prevent damage to normal tissue. On the basis of the above phenomenon, we further realize high spatial resolution photothermal ablation of labelled tumour with minimal damage to normal tissues in vivo. Our work points to a method for investigating photothermal properties at nanoscale, and for the development of new generation of PTT strategy. PMID:26842674

  12. Temperature-feedback upconversion nanocomposite for accurate photothermal therapy at facile temperature.

    PubMed

    Zhu, Xingjun; Feng, Wei; Chang, Jian; Tan, Yan-Wen; Li, Jiachang; Chen, Min; Sun, Yun; Li, Fuyou

    2016-02-04

    Photothermal therapy (PTT) at present, following the temperature definition for conventional thermal therapy, usually keeps the temperature of lesions at 42-45 °C or even higher. Such high temperature kills cancer cells but also increases the damage of normal tissues near lesions through heat conduction and thus brings about more side effects and inhibits therapeutic accuracy. Here we use temperature-feedback upconversion nanoparticle combined with photothermal material for real-time monitoring of microscopic temperature in PTT. We observe that microscopic temperature of photothermal material upon illumination is high enough to kill cancer cells when the temperature of lesions is still low enough to prevent damage to normal tissue. On the basis of the above phenomenon, we further realize high spatial resolution photothermal ablation of labelled tumour with minimal damage to normal tissues in vivo. Our work points to a method for investigating photothermal properties at nanoscale, and for the development of new generation of PTT strategy.

  13. Warm Season Temperatures and Emergency Department Visits in Atlanta, Georgia

    PubMed Central

    Winquist, Andrea; Grundstein, Andrew; Chang, Howard H.; Hess, Jeremy; Sarnat, Stefanie Ebelt

    2016-01-01

    Purpose Extreme heat events will likely increase in frequency with climate change. Heat-related health effects are better documented among the elderly than among younger age groups. We assessed associations between warm-season ambient temperature and emergency department (ED) visits across ages in Atlanta during 1993-2012. Methods We examined daily counts of ED visits with primary diagnoses of heat illness, fluid/electrolyte imbalances, renal disease, cardiorespiratory diseases, and intestinal infections by age group (0-4, 5-18, 19-64, 65+ years) in relation to daily maximum temperature (TMX) using Poisson time series models that included cubic terms for TMX at single-day lags of 0-6 days, controlling for maximum dew-point temperature, time trends, week day, holidays, and hospital participation periods. We estimated rate ratios (RRs) and 95% confidence intervals (CI) for TMX changes from 27 °C to 32 °C (25th to 75th percentile) and conducted extensive sensitivity analyses. Results We observed associations between TMX and ED visits for all internal causes, heat illness, fluid/electrolyte imbalances, renal diseases, asthma/wheeze, diabetes, and intestinal infections. Age groups with the strongest observed associations were 65+ years for all internal causes [lag 0 RR (CI)=1.022 (1.016-1.028)] and diabetes [lag 0 RR=1.050 (1.008-1.095)]; 19-64 years for fluid/electrolyte imbalances [lag 0 RR=1.170 (1.136-1.205)] and renal disease [lag 1 RR=1.082 (1.065-1.099)]; and 5-18 years for asthma/wheeze [lag 2 RR=1.059 (1.030-1.088)] and intestinal infections [lag 1 RR=1.120 (1.041-1.205)]. Conclusions Varying strengths of associations between TMX and ED visits by age suggest that optimal interventions and health-impact projections would account for varying heat health impacts across ages. PMID:26922412

  14. Observation and modelling of urban dew

    NASA Astrophysics Data System (ADS)

    Richards, Katrina

    Despite its relevance to many aspects of urban climate and to several practical questions, urban dew has largely been ignored. Here, simple observations an out-of-doors scale model, and numerical simulation are used to investigate patterns of dewfall and surface moisture (dew + guttation) in urban environments. Observations and modelling were undertaken in Vancouver, B.C., primarily during the summers of 1993 and 1996. Surveys at several scales (0.02-25 km) show that the main controls on dew are weather, location and site configuration (geometry and surface materials). Weather effects are discussed using an empirical factor, FW . Maximum dew accumulation (up to ~ 0.2 mm per night) is seen on nights with moist air and high FW , i.e., cloudless conditions with light winds. Favoured sites are those with high Ysky and surfaces which cool rapidly after sunset, e.g., grass and well insulated roofs. A 1/8-scale model is designed, constructed, and run at an out-of-doors site to study dew patterns in an urban residential landscape which consists of house lots, a street and an open grassed park. The Internal Thermal Mass (ITM) approach is used to scale the thermal inertia of buildings. The model is validated using data from full-scale sites in Vancouver. Patterns in the model agree with those seen at the full-scale, i.e., dew distribution is governed by weather, site geometry and substrate conditions. Correlation is shown between Ysky and surface moisture accumulation. The feasibility of using a numerical model to simulate urban dew is investigated using a modified version of a rural dew model. Results for simple isolated surfaces-a deciduous tree leaf and an asphalt shingle roof-show promise, especially for built surfaces.

  15. Body/bone-marrow differential-temperature sensor

    NASA Technical Reports Server (NTRS)

    Anselmo, V. J.; Berdahl, C. M.

    1978-01-01

    Differential-temperature sensor developed to compare bone-marrow and body temperature in leukemia patients uses single stable amplifier to monitor temperature difference recorded by thermocouples. Errors are reduced by referencing temperatures to each other, not to separate calibration points.

  16. Development of an experimental variable temperature set-up for a temperature range from 2.2 K to 325 K for cost-effective temperature sensor calibration

    NASA Astrophysics Data System (ADS)

    Pal, Sandip; Kar, Ranjan; Mandal, Anupam; Das, Ananda; Saha, Subrata

    2017-05-01

    A prototype of a variable temperature insert has been developed in-house as a cryogenic thermometer calibration facility. It was commissioned in fulfilment of the very stringent requirements of the temperature control of the cryogenic system. The calibration facility is designed for calibrating industrial cryogenic thermometers that include a temperature sensor and the wires heat-intercept in the 2.2 K-325 K temperature range. The isothermal section of the calibration block onto which the thermometers are mounted is weakly linked with the temperature control zone mounted with cooling capillary coil and cryogenic heater. The connecting wires of the thermometer are thermally anchored with the support of the temperature insert. The calibration procedure begins once the temperature of the support is stabilized. Homogeneity of the calibration block’s temperature is established both by simulation and by cross-comparison of two calibrated sensors. The absolute uncertainty present in temperature measurement is calculated and found comparable with the measured uncertainty at different temperature points. Measured data is presented in comparison to the standard thermometers at fixed points and it is possible to infer that the absolute accuracy achieved is better than  ±0.5% of the reading in comparison to the fixed point temperature. The design and development of simpler, low cost equipment, and approach to analysis of the calibration results are discussed further in this paper, so that it can be easily devised by other researchers.

  17. The gallium melting-point standard: a determination of the liquid-solid equilibrium temperature of pure gallium on the International Practical Temperature Scale of 1968.

    PubMed

    Thornton, D D

    1977-01-01

    The sharpness and reproducibility of the gallium melting point were studied and the melting temperature of gallium in terms of IPTS-68 was determined. Small melting-point cells designed for use with thermistors are described. Nine gallium cells including three levels of purity were used in 68 separate determinations fo the melting point. The melting point of 99.99999% pure gallium in terms of IPTS-68 is found to be 29.771(4) +/- 0.001(4) degree C; the melting range is less than 0.0005 degree C and is reproducible to +/- 0.0004 degree C.

  18. Targeted Nanoparticle Thermometry: A Method to Measure Local Temperature at the Nanoscale Point Where Water Vapor Nucleation Occurs.

    PubMed

    Alaulamie, Arwa A; Baral, Susil; Johnson, Samuel C; Richardson, Hugh H

    2017-01-01

    An optical nanothermometer technique based on laser trapping, moving and targeted attaching an erbium oxide nanoparticle cluster is developed to measure the local temperature. The authors apply this new nanoscale temperature measuring technique (limited by the size of the nanoparticles) to measure the temperature of vapor nucleation in water. Vapor nucleation is observed after superheating water above the boiling point for degassed and nondegassed water. The average nucleation temperature for water without gas is 560 K but this temperature is lowered by 100 K when gas is introduced into the water. The authors are able to measure the temperature inside the bubble during bubble formation and find that the temperature inside the bubble spikes to over 1000 K because the heat source (optically-heated nanorods) is no longer connected to liquid water and heat dissipation is greatly reduced. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  19. On two special values of temperature factor in hypersonic flow stagnation point

    NASA Astrophysics Data System (ADS)

    Bilchenko, G. G.; Bilchenko, N. G.

    2018-03-01

    The hypersonic aircraft permeable cylindrical and spherical surfaces laminar boundary layer heat and mass transfer control mathematical model properties are investigated. The nonlinear algebraic equations systems are obtained for two special values of temperature factor in the hypersonic flow stagnation point. The mappings bijectivity between heat and mass transfer local parameters and controls is established. The computation experiments results are presented: the domains of allowed values “heat-friction” are obtained.

  20. Dynamic Performance of Maximum Power Point Trackers in TEG Systems Under Rapidly Changing Temperature Conditions

    NASA Astrophysics Data System (ADS)

    Man, E. A.; Sera, D.; Mathe, L.; Schaltz, E.; Rosendahl, L.

    2016-03-01

    Characterization of thermoelectric generators (TEG) is widely discussed and equipment has been built that can perform such analysis. One method is often used to perform such characterization: constant temperature with variable thermal power input. Maximum power point tracking (MPPT) methods for TEG systems are mostly tested under steady-state conditions for different constant input temperatures. However, for most TEG applications, the input temperature gradient changes, exposing the MPPT to variable tracking conditions. An example is the exhaust pipe on hybrid vehicles, for which, because of the intermittent operation of the internal combustion engine, the TEG and its MPPT controller are exposed to a cyclic temperature profile. Furthermore, there are no guidelines on how fast the MPPT must be under such dynamic conditions. In the work discussed in this paper, temperature gradients for TEG integrated in several applications were evaluated; the results showed temperature variation up to 5°C/s for TEG systems. Electrical characterization of a calcium-manganese oxide TEG was performed at steady-state for different input temperatures and a maximum temperature of 401°C. By using electrical data from characterization of the oxide module, a solar array simulator was emulated to perform as a TEG. A trapezoidal temperature profile with different gradients was used on the TEG simulator to evaluate the dynamic MPPT efficiency. It is known that the perturb and observe (P&O) algorithm may have difficulty accurately tracking under rapidly changing conditions. To solve this problem, a compromise must be found between the magnitude of the increment and the sampling frequency of the control algorithm. The standard P&O performance was evaluated experimentally by using different temperature gradients for different MPPT sampling frequencies, and efficiency values are provided for all cases. The results showed that a tracking speed of 2.5 Hz can be successfully implemented on a TEG

  1. [Effects of temperature and salinity on oxygen consumption rate and asphyxiation point of Sagitta crassa].

    PubMed

    Liu, Qing; Zhu, Hai-Yan; Liu, Fang; Ding, Zi-Yuan

    2011-11-01

    A laboratory test was conducted to study the effects of different temperature and salinity on the oxygen consumption rate and asphyxiation point of chaetognath Sagitta crassa. Both temperature and salinity had significant effects on the oxygen consumption rate (IO) and specific oxygen consumption rate (SO) of S. crassa. When the temperature raised from 5 degrees C to 25 degrees C, the IO and SO of S. crassa increased first, and then presented an obvious decreasing trend, with the regression function being y = 0.0058x3-0.2956x2 +4.415x-8.7816 (R2 = 0.99, P < 0.05) for IO and y = 0.0011x3-0.0546x2+0.8161x-1.6232 (R2 = 0.99, P < 0.05) for SO. The IO and SO at different temperature were in the ranges of 6.30-11.71 microg x ind(-1) x h(-1) and 1.22-2.16 microg x mg(-1) x h(-1), respectively, and the asphyxiation point was 4.18-6.87 mg x L(-1). When the salinity increased from 10 to 40, the IO and SO of S. crassa decreased gradually, with the regression function being y = -0.0068x2-0.1412x+21.702 (R2 = 0.89, P < 0.05) for IO and y = -0.0013x2 -0.0261x+ 4.0114 (R2 = 0.89, P < 0.05) for SO. The IO and SO at different salinity were in the ranges of 4.98-17.73 microg x ind(-1) x h(-1) and 0.92-3.56 microg x mg(-1) x h(-1), respectively, and the asphyxiation point was 4.02-6.24 mg x L(-1). Based on the differences in the oxygen consumption rate and asphyxiation point between S. crassa and other aquatic animals, it was concluded that S. crassa was a stenooxybiotic zooplankton species.

  2. New fixed-point mini-cell to investigate thermocouple drift in a high-temperature environment under neutron irradiation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Laurie, M.; Vlahovic, L.; Rondinella, V.V.

    Temperature measurements in the nuclear field require a high degree of reliability and accuracy. Despite their sheathed form, thermocouples subjected to nuclear radiations undergo changes due to radiation damage and transmutation that lead to significant EMF drift during long-term fuel irradiation experiment. For the purpose of a High Temperature Reactor fuel irradiation to take place in the High Flux Reactor Petten, a dedicated fixed-point cell was jointly developed by LNE-Cnam and JRC-IET. The developed cell to be housed in the irradiation rig was tailor made to quantify the thermocouple drift during the irradiation (about two year duration) and withstand highmore » temperature (in the range 950 deg. C - 1100 deg. C) in the presence of contaminated helium in a graphite environment. Considering the different levels of temperature achieved in the irradiation facility and the large palette of thermocouple types aimed at surveying the HTR fuel pebble during the qualification test both copper (1084.62 deg. C) and gold (1064.18 deg. C) fixed-point materials were considered. The aim of this paper is to first describe the fixed-point mini-cell designed to be embedded in the reactor rig and to discuss the preliminary results achieved during some out of pile tests as much as some robustness tests representative of the reactor scram scenarios. (authors)« less

  3. Radiant Temperature Nulling Radiometer

    NASA Technical Reports Server (NTRS)

    Ryan, Robert (Inventor)

    2003-01-01

    A self-calibrating nulling radiometer for non-contact temperature measurement of an object, such as a body of water, employs a black body source as a temperature reference, an optomechanical mechanism, e.g., a chopper, to switch back and forth between measuring the temperature of the black body source and that of a test source, and an infrared detection technique. The radiometer functions by measuring radiance of both the test and the reference black body sources; adjusting the temperature of the reference black body so that its radiance is equivalent to the test source; and, measuring the temperature of the reference black body at this point using a precision contact-type temperature sensor, to determine the radiative temperature of the test source. The radiation from both sources is detected by an infrared detector that converts the detected radiation to an electrical signal that is fed with a chopper reference signal to an error signal generator, such as a synchronous detector, that creates a precision rectified signal that is approximately proportional to the difference between the temperature of the reference black body and that of the test infrared source. This error signal is then used in a feedback loop to adjust the reference black body temperature until it equals that of the test source, at which point the error signal is nulled to zero. The chopper mechanism operates at one or more Hertz allowing minimization of l/f noise. It also provides pure chopping between the black body and the test source and allows continuous measurements.

  4. FIRE_AX_SOF_ARAT_FLT

    Atmospheric Science Data Center

    2015-11-25

    ... Microwave Radiometer Optical Counter Platinum Resistance Pyranometer Pyrgeometer Variable Capacitance ... Parameters:  Aerosol Particle Properties Air Temperature Cloud Liquid Water Deiced Temperature Dew Point Doppler ...

  5. Analyzing nearly four decades of historical radiosonde observations of tropical tropopause layer and cold-point temperatures

    NASA Astrophysics Data System (ADS)

    Gilford, D.; Randel, W. J.

    2017-12-01

    An understanding of historical trends and variability in the thermal structure of the tropical tropopause layer (TTL) is important for assessing climate and investigating TTL processes. In particular, the cold-point tropopause (CPT) plays an important role in stratospheric dehydration, the potential intensities of tropical cyclones, and other forms of stratospheric-tropospheric coupling. Uncertainties and biases of in-situ observations, however, make long-term estimation of TTL temperatures challenging, especially in the early decades of the satellite era. The goal of this study is to construct and analyze a long-term record of radiosondes temperatures with minimal biases. Temperature observations from 1979-present are drawn from the Integrated Global Radiosonde Archive version 2 (IGRA2). Vertically integrated radiosonde temperatures are compared with brightness temperatures from the Microwave Sounding Units (MSU) Lower Stratosphere channel to identify the radiosonde stations with the smallest temporal discontinuities. Insights from this comparison highlight the importance of independent measurements when evaluating TTL temperatures. The 38-year dataset constructed from IGRA2 stations with the smallest biases spans the tropics and has high vertical resolution, permitting reasonable estimates of the CPT temperature. Radiosonde temperatures show good agreement with GPS radio occultation measurements over the past decade. A multivariate regression model incorporating the Quasi-Biennial Oscillation and the El Nino Southern Oscillation is fit to the deseasonalized data to evaluate the spatial and temporal structures in its variability. Long-term trends in CPT temperatures are considered in the context of historical estimates from climate models. Correlations with TTL water vapor concentrations from the Stratospheric Water and OzOne Satellite Homogenized (SWOOSH) data set suggest a strong relationship between the historically observed CPT temperatures and dehydration.

  6. Rotational cars application to simultaneous and multiple-point temperature and concentration determination in a turbulent flow

    NASA Technical Reports Server (NTRS)

    Snow, J. B.; Murphy, D. V.; Chang, R. K.

    1984-01-01

    Coherent Anti-stokes Raman Scattering (CARS) from the pure rotational Raman lines of N2 is employed to measure the instantaneous rotational temperature of N2 gas at room temperature and below with good spatial resolution. A broad-bandwidth dye laser is used to obtain the entire rotational spectrum from a signal laser pulse; the CARS signal is then dispersed by a spectrograph and recorded on an optical multichannel analyzer. A best-fit temperature is found in several seconds with the aid of a computer for each experimental spectrum by a least squares comparison with calculated spectra. The model used to calculate the theoretical spectra incorporates the temperature and pressure dependence of the pressure-broadened rotational Raman lines, includes the nonresonant background susceptibility, and assumes that the pump laser has a finite linewidth. Temperatures are fit to experimental spectra recorded over the temperature range of 135 to 296K, and over the pressure range of 0.13 to 15.3 atm. In addition to the spatially resolved single point work, we have used multipoint CARS to obtain information from many spatially resolved volume elements along a cylindrical line (0.1 x 0.1 x 2.0 mm). We also obtained qualitative information on the instantaneous species concentration and temperature at 20 spatially resolved volume elements (0.1 x 0.1 x 0.1 mm) along a line.

  7. Localized saddle-point search and application to temperature-accelerated dynamics

    NASA Astrophysics Data System (ADS)

    Shim, Yunsic; Callahan, Nathan B.; Amar, Jacques G.

    2013-03-01

    We present a method for speeding up temperature-accelerated dynamics (TAD) simulations by carrying out a localized saddle-point (LSAD) search. In this method, instead of using the entire system to determine the energy barriers of activated processes, the calculation is localized by only including a small chunk of atoms around the atoms directly involved in the transition. Using this method, we have obtained N-independent scaling for the computational cost of the saddle-point search as a function of system size N. The error arising from localization is analyzed using a variety of model systems, including a variety of activated processes on Ag(100) and Cu(100) surfaces, as well as multiatom moves in Cu radiation damage and metal heteroepitaxial growth. Our results show significantly improved performance of TAD with the LSAD method, for the case of Ag/Ag(100) annealing and Cu/Cu(100) growth, while maintaining a negligibly small error in energy barriers.

  8. Investigation of the effects of pressure gradient, temperature and wall temperature ratio on the stagnation point heat transfer for circular cylinders and gas turbine vanes

    NASA Technical Reports Server (NTRS)

    Nagamatsu, H. T.; Duffy, R. E.

    1984-01-01

    Low and high pressure shock tubes were designed and constructed for the purpose of obtaining heat transfer data over a temperature range of 390 to 2500 K, pressures of 0.3 to 42 atm, and Mach numbers of 0.15 to 1.5 with and without pressure gradient. A square test section with adjustable top and bottom walls was constructed to produce the favorable and adverse pressure gradient over the flat plate with heat gages. A water cooled gas turbine nozzle cascade which is attached to the high pressure shock tube was obtained to measuse the heat flux over pressure and suction surfaces. Thin-film platinum heat gages with a response time of a few microseconds were developed and used to measure the heat flux for laminar, transition, and turbulent boundary layers. The laminar boundary heat flux on the shock tube wall agreed with Mirel's flat plate theory. Stagnation point heat transfer for circular cylinders at low temperature compared with the theoretical prediction, but for a gas temperature of 922 K the heat fluxes were higher than the predicted values. Preliminary flat plate heat transfer data were measured for laminar, transition, and turbulent boundary layers with and without pressure gradients for free-stream temperatures of 350 to 2575 K and flow Mach numbers of 0.11 to 1.9. The experimental heat flux data were correlated with the laminar and turbulent theories and the agreement was good at low temperatures which was not the case for higher temperatures.

  9. Penrose Well Temperatures

    DOE Data Explorer

    Christopherson, Karen

    2013-03-15

    Penrose Well Temperatures Geothermal waters have been encountered in several wells near Penrose in Fremont County, Colorado. Most of the wells were drilled for oil and gas exploration and, in a few cases, production. This ESRI point shapefile utilizes data from 95 wells in and around the Penrose area provided by the Colorado Oil and Gas Conservation Commission (COGCC) database at http://cogcc.state.co.us/ . Temperature data from the database were used to calculate a temperature gradient for each well. This information was then used to estimate temperatures at various depths. Projection: UTM Zone 13 NAD27 Extent: West -105.224871 East -105.027633 North 38.486269 South 38.259507 Originators: Colorado Oil and Gas Conservation Commission (COGCC) Karen Christopherson

  10. Core body temperature in obesity.

    PubMed

    Heikens, Marc J; Gorbach, Alexander M; Eden, Henry S; Savastano, David M; Chen, Kong Y; Skarulis, Monica C; Yanovski, Jack A

    2011-05-01

    A lower core body temperature set point has been suggested to be a factor that could potentially predispose humans to develop obesity. We tested the hypothesis that obese individuals have lower core temperatures than those in normal-weight individuals. In study 1, nonobese [body mass index (BMI; in kg/m(2)) <30] and obese (BMI ≥30) adults swallowed wireless core temperature-sensing capsules, and we measured core temperatures continuously for 24 h. In study 2, normal-weight (BMI of 18-25) and obese subjects swallowed temperature-sensing capsules to measure core temperatures continuously for ≥48 h and kept activity logs. We constructed daily, 24-h core temperature profiles for analysis. Mean (±SE) daily core body temperature did not differ significantly between the 35 nonobese and 46 obese subjects (36.92 ± 0.03°C compared with 36.89 ± 0.03°C; P = 0.44). Core temperature 24-h profiles did not differ significantly between 11 normal-weight and 19 obese subjects (P = 0.274). Women had a mean core body temperature ≈0.23°C greater than that of men (36.99 ± 0.03°C compared with 36.76 ± 0.03°C; P < 0.0001). Obesity is not generally associated with a reduced core body temperature. It may be necessary to study individuals with function-altering mutations in core temperature-regulating genes to determine whether differences in the core body temperature set point affect the regulation of human body weight. These trials were registered at clinicaltrials.gov as NCT00428987 and NCT00266500.

  11. FIRE_MS_UKMO_C130

    Atmospheric Science Data Center

    2015-11-25

    ... Hot-Wire MCRW Refractometer Platinum Resistance Pressure Transducer RT-4 Pyranometer Pyrgeometer Radiometer Wind ... Parameters:  Dew/Frost Point Temperature Liquid Water Content Humidity Temperature Pressure Irradiance ...

  12. Statistical Correction of Air Temperature Forecasts for City and Road Weather Applications

    NASA Astrophysics Data System (ADS)

    Mahura, Alexander; Petersen, Claus; Sass, Bent; Gilet, Nicolas

    2014-05-01

    that the CPU time required for the operational procedure is relatively short (less than 15 minutes including a large time spent for interpolation). These also showed that in order to start correction of forecasts there is no need to have a long-term pre-historical data (containing forecasts and observations) and, at least, a couple of weeks will be sufficient when a new observational station is included and added to the forecast point. Note for the road weather application, the operationalization of the statistical correction of the road surface temperature forecasts (for the RWM system daily hourly runs covering forecast length up to 5 hours ahead) for the Danish road network (for about 400 road stations) was also implemented, and it is running in a test mode since Sep 2013. The method can also be applied for correction of the dew point temperature and wind speed (as a part of observations/ forecasts at synoptical stations), where these both meteorological parameters are parts of the proposed system of equations. The evaluation of the method performance for improvement of the wind speed forecasts is planned as well, with considering possibilities for the wind direction improvements (which is more complex due to multi-modal types of such data distribution). The method worked for the entire domain of mainland Denmark (tested for 60 synoptical and 395 road stations), and hence, it can be also applied for any geographical point within this domain, as through interpolation to about 100 cities' locations (for Danish national byvejr forecasts). Moreover, we can assume that the same method can be used in other geographical areas. The evaluation for other domains (with a focus on Greenland and Nordic countries) is planned. In addition, a similar approach might be also tested for statistical correction of concentrations of chemical species, but such approach will require additional elaboration and evaluation.

  13. WGM Temperature Tracker

    NASA Technical Reports Server (NTRS)

    Strekalov, Dmitry V.

    2012-01-01

    This software implements digital control of a WGM (whispering-gallerymode) resonator temperature based on the dual-mode approach. It comprises one acquisition (dual-channel) and three control modules. The interaction of the proportional-integral loops is designed in the original way, preventing the loops from fighting. The data processing is organized in parallel with the acquisition, which allows the computational overhead time to be suppressed or often completely avoided. WGM resonators potentially provide excellent optical references for metrology, clocks, spectroscopy, and other applications. However, extremely accurate (below micro-Kelvin) temperature stabilization is required. This software allows one specifically advantageous method of such stabilization to be implemented, which is immune to a variety of effects that mask the temperature variation. WGM Temperature Tracker 2.3 (see figure) is a LabVIEW code developed for dual-mode temperature stabilization of WGM resonators. It has allowed for the temperature stabilization at the level of 200 nK with one-second integration time, and 6 nK with 10,000-second integration time, with the above room-temperature set point. This software, in conjunction with the appropriate hardware, can be used as a noncryogenic temperature sensor/ controller with sub-micro-Kelvin sensitivity, which at the time of this reporting considerably outperforms the state of the art.

  14. Optimal Body Temperature in Transitional ELBW Infants Using Heart Rate and Temperature as Indicators

    PubMed Central

    Knobel, Robin B.; Holditch-Davis, Diane; Schwartz, Todd A.

    2013-01-01

    Extremely low birth weight (ELBW) infants are vulnerable to cold stress after birth. Therefore, caregivers need to control body temperature optimally to minimize energy expenditure. Objective We explored body temperature in relationship to heart rate in ELBW infants during their first 12 hours to help identify the ideal set point for incubator control of body temperature. Design Within subject, multiple-case design. Setting A tertiary NICU in North Carolina. Participants 10 infants, born less than 29 weeks gestation and weighing 400-1000 grams. Methods Heart rate and abdominal body temperature were measured at 1-minute intervals for 12 hours. Heart rates were considered normal if they were between the 25th and 75th percentile for each infant. Results Abdominal temperatures were low throughout the 12-hour study period (mean 35.17° C-36.68° C). Seven of ten infants had significant correlations between abdominal temperature and heart rate. Heart rates above the 75th percentile were associated with low and high abdominal temperatures; heart rates less than the 25th percentile were associated with very low abdominal temperatures. The extent to which abdominal temperature was abnormally low was related the extent to which the heart rate trended away from normal in six of the ten infants. Optimal temperature control point that maximized normal heart rate observations for each infant was between 36.8° C and 37° C. Conclusions Hypothermia was associated with abnormal heart rates in transitional ELBW infants. We suggest nurses set incubator servo between 36.8° C and 36.9° C to optimally control body temperature for ELBW infants. PMID:20409098

  15. Triple point temperature of neon isotopes: Dependence on nitrogen impurity and sealed-cell model

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pavese, F.; Steur, P. P. M.; Giraudi, D.

    2013-09-11

    This paper illustrates a study conducted at INRIM, to further check how some quantities influence the value of the triple point temperature of the neon high-purity isotopes {sup 20}Ne and {sup 22}Ne. The influence of nitrogen as a chemical impurity in neon is critical with regard to the present best total uncertainty achieved in the measurement of these triple points, but only one determination is available in the literature. Checks are reported, performed on two different samples of {sup 22}Ne known to contain a N{sub 2} amount of 157⋅10{sup −6}, using two different models of sealed cells. The model ofmore » the cell can, in principle, have some effects on the shape of the melting plateau or on the triple point temperature observed for the sample sealed in it. This can be due to cell thermal parameters, or because the INRIM cell element mod. c contains many copper wires closely packed, which can, in principle, constrain the interface and induce a premelting-like effect. The reported results on a cell mod. Bter show no evident effect from the cell model and provide a value for the effect of N{sub 2} in Ne liquidus point of 8.6(1.9) μK ppm N{sub 2}{sup −1}, only slightly different from the literature datum.« less

  16. The New Lunar Meteorite DEW 12007

    NASA Astrophysics Data System (ADS)

    Collareta, A.; D'Orazio, M.; Gemelli, M.; Pack, A.; Folco, L.

    2014-09-01

    The new lunar meteorite DEW 12007 was found in Antarctica in January 2013 by PNRA. DEW 12007 has been classified as a regolithic breccia of mingled composition. In our abstract we present its first-order geochemical and petrographic features.

  17. Loop Heat Pipe Transient Behavior Using Heat Source Temperature for Set Point Control with Thermoelectric Converter on Reservoir

    NASA Technical Reports Server (NTRS)

    Ku, Jentung; Paiva, Kleber; Mantelli, Marcia

    2011-01-01

    The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly done by cold biasing the reservoir and using electrical heaters to provide the required control power. With this method, the loop operating temperature can be controlled within 0.5K or better. However, because the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if the LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP was carried out to investigate the effects on the LHP operation when the control temperature sensor was placed on the heat source instead of the reservoir. In these tests, the LHP reservoir was cold-biased and was heated by a control heater. Test results show that it was feasible to use the heat source temperature for feedback control of the LHP operation. In particular, when a thermoelectric converter was used as the reservoir control heater, the heat source temperature could be maintained within a tight range using a proportional-integral-derivative or on/off control algorithm. Moreover, because the TEC could provide both heating and cooling to the reservoir, temperature oscillations during fast transients such as loop startup could be eliminated or substantially reduced when compared to using an electrical heater as the control heater.

  18. Detection of trends and break points in temperature: the case of Umbria (Italy) and Guadalquivir Valley (Spain)

    NASA Astrophysics Data System (ADS)

    Herrera-Grimaldi, Pascual; García-Marín, Amanda; Ayuso-Muñoz, José Luís; Flamini, Alessia; Morbidelli, Renato; Ayuso-Ruíz, José Luís

    2018-02-01

    The increase of air surface temperature at global scale is a fact with values around 0.85 °C since the late nineteen century. Nevertheless, the increase is not equally distributed all over the world, varying from one region to others. Thus, it becomes interesting to study the evolution of temperature indices for a certain area in order to analyse the existence of climatic trend in it. In this work, monthly temperature time series from two Mediterranean areas are used: the Umbria region in Italy, and the Guadalquivir Valley in southern Spain. For the available stations, six temperature indices (three annual and three monthly) of mean, average maximum and average minimum temperature have been obtained, and the existence of trends has been studied by applying the non-parametric Mann-Kendall test. Both regions show a general increase in all temperature indices, being the pattern of the trends clearer in Spain than in Italy. The Italian area is the only one at which some negative trends are detected. The presence of break points in the temperature series has been also studied by using the non-parametric Pettit test and the parametric standard normal homogeneity test (SNHT), most of which may be due to natural phenomena.

  19. Challenging the distributed temperature sensing technique for estimating groundwater discharge to streams through controlled artificial point source experiment

    NASA Astrophysics Data System (ADS)

    Lauer, F.; Frede, H.-G.; Breuer, L.

    2012-04-01

    Spatially confined groundwater discharge can contribute significantly to stream discharge. Distributed fibre optic temperature sensing (DTS) of stream water has been successfully used to localize- and quantify groundwater discharge from this type "point sources" (PS) in small first-order streams. During periods when stream and groundwater temperatures differ PS appear as abrupt step in longitudinal stream water temperature distribution. Based on stream temperature observation up- and downstream of a point source and estimated or measured groundwater temperature the proportion of groundwater inflow to stream discharge can be quantified using simple mixing models. However so far this method has not been quantitatively verified, nor has a detailed uncertainty analysis of the method been conducted. The relative accuracy of this method is expected to decrease nonlinear with decreasing proportions of lateral inflow. Furthermore it depends on the temperature differences (ΔT) between groundwater and surface water and on the accuracy of temperature measurement itself. The latter could be affected by different sources of errors. For example it has been shown that a direct impact of solar radiation on fibre optic cables can lead to errors in temperature measurements in small streams due to low water depth. Considerable uncertainty might also be related to the determination of groundwater temperature through direct measurements or derived from the DTS signal. In order to directly validate the method and asses it's uncertainty we performed a set of artificial point source experiments with controlled lateral inflow rates to a natural stream. The experiments were carried out at the Vollnkirchener Bach, a small head water stream in Hessen, Germany in November and December 2011 during a low flow period. A DTS system was installed along a 1.2 km sub reach of the stream. Stream discharge was measured using a gauging flume installed directly upstream of the artificial PS. Lateral

  20. Perceived temperature in the course of climate change: an analysis of global heat index from 1979 to 2013

    NASA Astrophysics Data System (ADS)

    Lee, D.; Brenner, T.

    2015-08-01

    The increase in global mean temperatures resulting from climate change has wide reaching consequences for the earth's ecosystems and other natural systems. Many studies have been devoted to evaluating the distribution and effects of these changes. We go a step further and propose the use of the heat index, a measure of the temperature as perceived by humans, to evaluate global changes. The heat index, which is computed from temperature and relative humidity, is more important than temperature for the health of humans and animals. Even in cases where the heat index does not reach dangerous levels from a health perspective, it has been shown to be an important factor in worker productivity and thus in economic productivity. We compute the heat index from dew point temperature and absolute temperature 2 m above ground from the ERA-Interim reanalysis data set for the years 1979-2013. The described data set provides global heat index aggregated to daily minima, means and maxima per day (doi:10.1594/PANGAEA.841057). This paper examines these data, as well as showing aggregations to monthly and yearly values. Furthermore, the data are spatially aggregated to the level of countries after being weighted by population density in order to facilitate the analysis of its impact on human health and productivity. The resulting data deliver insights into the spatiotemporal development of near-ground heat index during the course of the past three decades. It is shown that the impact of changing heat index is unevenly distributed through space and time, affecting some areas differently than others. The data can serve as a basis for evaluating and understanding the evolution of heat index in the course of climate change, as well as its impact on human health and productivity.

  1. Temperature measuring device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lauf, R.J.; Bible, D.W.; Sohns, C.W.

    1999-10-19

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.

  2. Temperature measuring device

    DOEpatents

    Lauf, Robert J.; Bible, Don W.; Sohns, Carl W.

    1999-01-01

    Systems and methods are described for a wireless instrumented silicon wafer that can measure temperatures at various points and transmit those temperature readings to an external receiver. The device has particular utility in the processing of semiconductor wafers, where it can be used to map thermal uniformity on hot plates, cold plates, spin bowl chucks, etc. without the inconvenience of wires or the inevitable thermal perturbations attendant with them.

  3. FIRE_CI2_CITATN_1HZ

    Atmospheric Science Data Center

    2015-11-25

    ... Flow Angle Sensors Hot-Wire Icing Rate Detector Pressure Transducer Reverse Flow Temperature Probes Spatial ... Condensation Nuclei Dew/Frost Point Temperature Liquid Water Content Nitrogen Dioxide Ozone Pressure Supercooled ...

  4. Effect of irrigation fluid temperature on body temperature during arthroscopic elbow surgery in dogs.

    PubMed

    Thompson, K R; MacFarlane, P D

    2013-01-01

    This prospective randomised clinical trial evaluated the effect of warmed irrigation fluid on body temperature in anaesthetised dogs undergoing arthroscopic elbow surgery. Nineteen dogs undergoing elbow arthroscopy were included in the study and were randomly allocated to one of two groups. Group RT received irrigation fluid at room temperature (RT) while dogs in group W received warmed (W) irrigation fluid (36°C). A standardised patient management and anaesthetic protocol was used and body temperature was measured at four time points; (T1) pre-anaesthetic examination, (T2) arrival into theatre, (T3) end of surgery and (T4) arrival into recovery. There was no significant difference in body temperature at any time point between the groups. The mean overall decrease in body temperature between pre-anaesthetic examination (T1) and return to the recovery suite (T4) was significant in both groups, with a fall of 1.06±0.58°C (p<0.001) in group RT and 1.53±0.76°C (p<0.001) group W. There was no significant difference between the groups. At the end of surgery (T3) 4/19 (21.1%) of dogs were hypothermic (<37°C). The addition of warmed irrigation fluids to a temperature management protocol in dogs undergoing elbow arthroscopy during general anaesthesia did not lead to decreased temperature losses.

  5. Effect of irrigation fluid temperature on body temperature during arthroscopic elbow surgery in dogs

    PubMed Central

    Thompson, K.R.; MacFarlane, P.D.

    2013-01-01

    This prospective randomised clinical trial evaluated the effect of warmed irrigation fluid on body temperature in anaesthetised dogs undergoing arthroscopic elbow surgery. Nineteen dogs undergoing elbow arthroscopy were included in the study and were randomly allocated to one of two groups. Group RT received irrigation fluid at room temperature (RT) while dogs in group W received warmed (W) irrigation fluid (36°C). A standardised patient management and anaesthetic protocol was used and body temperature was measured at four time points; (T1) pre-anaesthetic examination, (T2) arrival into theatre, (T3) end of surgery and (T4) arrival into recovery. There was no significant difference in body temperature at any time point between the groups. The mean overall decrease in body temperature between pre-anaesthetic examination (T1) and return to the recovery suite (T4) was significant in both groups, with a fall of 1.06±0.58°C (p<0.001) in group RT and 1.53±0.76°C (p<0.001) group W. There was no significant difference between the groups. At the end of surgery (T3) 4/19 (21.1%) of dogs were hypothermic (<37°C). The addition of warmed irrigation fluids to a temperature management protocol in dogs undergoing elbow arthroscopy during general anaesthesia did not lead to decreased temperature losses. PMID:26623323

  6. Atmospheric moisture's influence on fire behavior: surface moisture and plume dynamics.

    Treesearch

    Brian E. Potter; Joseph J. Charney; Lesley A. Fusina

    2006-01-01

    Nine measures of atmospheric surface moisture are tested for statistical relationships with fire size and number of fires using data from the Great Lakes region of the United States. The measures include relative humidity, water vapor mixing ratio, mixing ratio deficit, vapor pressure, vapor pressure deficit, dew point temperature, dew point depression, wet bulb...

  7. Dew Worms in the White Nights

    USDA-ARS?s Scientific Manuscript database

    Lumbricus terrestris L. (the dew worm) forages, mates and migrates on the soil surface during the night. Its distribution covers a broad latitudinal gradient and variation in day length conditions. Since soil-surface activity is crucial for the survival and reproduction of dew worms, it is conceivab...

  8. The Kelvin and Temperature Measurements

    PubMed Central

    Mangum, B. W.; Furukawa, G. T.; Kreider, K. G.; Meyer, C. W.; Ripple, D. C.; Strouse, G. F.; Tew, W. L.; Moldover, M. R.; Johnson, B. Carol; Yoon, H. W.; Gibson, C. E.; Saunders, R. D.

    2001-01-01

    The International Temperature Scale of 1990 (ITS-90) is defined from 0.65 K upwards to the highest temperature measurable by spectral radiation thermometry, the radiation thermometry being based on the Planck radiation law. When it was developed, the ITS-90 represented thermodynamic temperatures as closely as possible. Part I of this paper describes the realization of contact thermometry up to 1234.93 K, the temperature range in which the ITS-90 is defined in terms of calibration of thermometers at 15 fixed points and vapor pressure/temperature relations which are phase equilibrium states of pure substances. The realization is accomplished by using fixed-point devices, containing samples of the highest available purity, and suitable temperature-controlled environments. All components are constructed to achieve the defining equilibrium states of the samples for the calibration of thermometers. The high quality of the temperature realization and measurements is well documented. Various research efforts are described, including research to improve the uncertainty in thermodynamic temperatures by measuring the velocity of sound in gas up to 800 K, research in applying noise thermometry techniques, and research on thermocouples. Thermometer calibration services and high-purity samples and devices suitable for “on-site” thermometer calibration that are available to the thermometry community are described. Part II of the paper describes the realization of temperature above 1234.93 K for which the ITS-90 is defined in terms of the calibration of spectroradiometers using reference blackbody sources that are at the temperature of the equilibrium liquid-solid phase transition of pure silver, gold, or copper. The realization of temperature from absolute spectral or total radiometry over the temperature range from about 60 K to 3000 K is also described. The dissemination of the temperature scale using radiation thermometry from NIST to the customer is achieved by

  9. Thermoelectric Control Of Temperatures Of Pressure Sensors

    NASA Technical Reports Server (NTRS)

    Burkett, Cecil G., Jr.; West, James W.; Hutchinson, Mark A.; Lawrence, Robert M.; Crum, James R.

    1995-01-01

    Prototype controlled-temperature enclosure containing thermoelectric devices developed to house electronically scanned array of pressure sensors. Enclosure needed because (1) temperatures of transducers in sensors must be maintained at specified set point to ensure proper operation and calibration and (2) sensors sometimes used to measure pressure in hostile environments (wind tunnels in original application) that are hotter or colder than set point. Thus, depending on temperature of pressure-measurement environment, thermoelectric devices in enclosure used to heat or cool transducers to keep them at set point.

  10. Cloud point phenomena for POE-type nonionic surfactants in a model room temperature ionic liquid.

    PubMed

    Inoue, Tohru; Misono, Takeshi

    2008-10-15

    The cloud point phenomenon has been investigated for the solutions of polyoxyethylene (POE)-type nonionic surfactants (C(12)E(5), C(12)E(6), C(12)E(7), C(10)E(6), and C(14)E(6)) in 1-butyl-3-methylimidazolium tetrafluoroborate (bmimBF(4)), a typical room temperature ionic liquid (RTIL). The cloud point, T(c), increases with the elongation of the POE chain, while decreases with the increase in the hydrocarbon chain length. This demonstrates that the solvophilicity/solvophobicity of the surfactants in RTIL comes from POE chain/hydrocarbon chain. When compared with an aqueous system, the chain length dependence of T(c) is larger for the RTIL system regarding both POE and hydrocarbon chains; in particular, hydrocarbon chain length affects T(c) much more strongly in the RTIL system than in equivalent aqueous systems. In a similar fashion to the much-studied aqueous systems, the micellar growth is also observed in this RTIL solvent as the temperature approaches T(c). The cloud point curves have been analyzed using a Flory-Huggins-type model based on phase separation in polymer solutions.

  11. The importance of dew in watershed-management research

    Treesearch

    James W. Hornbeck

    1964-01-01

    Many studies, using various methods, have been made of dew deposition to determine its importance as a source of moisture. For example, Duvdevani (1947) used an optical method in which dew collected on a wooden block was compared with a set of standardized photographs of dew. Potvin (1949) exposed diamond-shaped glass plates at 45º to ground level, so that...

  12. Distributed optical fiber temperature sensor (DOFTS) system applied to automatic temperature alarm of coal mine and tunnel

    NASA Astrophysics Data System (ADS)

    Zhang, Zaixuan; Wang, Kequan; Kim, Insoo S.; Wang, Jianfeng; Feng, Haiqi; Guo, Ning; Yu, Xiangdong; Zhou, Bangquan; Wu, Xiaobiao; Kim, Yohee

    2000-05-01

    The DOFTS system that has applied to temperature automatically alarm system of coal mine and tunnel has been researched. It is a real-time, on line and multi-point measurement system. The wavelength of LD is 1550 nm, on the 6 km optical fiber, 3000 points temperature signal is sampled and the spatial position is certain. Temperature measured region: -50 degree(s)C--100 degree(s)C; measured uncertain value: +/- 3 degree(s)C; temperature resolution: 0.1 degree(s)C; spatial resolution: <5 cm (optical fiber sensor probe); <8 m (spread optical fiber); measured time: <70 s. In the paper, the operated principles, underground test, test content and practical test results have been discussed.

  13. Thermoelectrically cooled temperature-gradient apparatus for comparative cell and virus temperature studies.

    PubMed

    Clark, H F; Kaminski, F; Karzon, D T

    1970-05-01

    Establishment of a near-linear temperature gradient in an incubator has been accomplished by the application of heat to one terminus of a conducting body, normally a metal bar, and the removal of heat from the other terminus of the conducting body. Such incubators have been complex and unwieldy because of the need for mechanical refrigeration. We have described a simplified temperature gradient incubator which uses thermoelectric module cooling coupled with electric heating. Along the gradient, 20 stations in two parallel rows of 10, each accommodating a 30-ml plastic cell culture flask, were continually monitored by an electronic thermometer, and the temperatures were recorded. By manipulation of two simple potentiometer controls, any temperature gradient between 0 and 50 C could be obtained. Minor deviations which occurred between theoretically perfect and obtained temperature gradients were reproducible and readily measured. The gradient incubator was particularly applicable to (i) simultaneously studying a given biological activity over the entire temperature range supporting the growth of a given cell, virus, or microorganism, or (ii) precisely defining the upper or lower temperature limits of a biological system by 10-point determinations. Preliminary experiments have demonstrated the usefulness of the apparatus in characterizing the temperature limits for growth in vitro of cells of reptilian cell lines. The gradient incubator was also successfully utilized for the characterization of the effect of temperature on the efficiency of plating of amphibian viruses and possible temperature variants of those viruses.

  14. A Peltier-based variable temperature source

    NASA Astrophysics Data System (ADS)

    Molki, Arman; Roof Baba, Abdul

    2014-11-01

    In this paper we propose a simple and cost-effective variable temperature source based on the Peltier effect using a commercially purchased thermoelectric cooler. The proposed setup can be used to quickly establish relatively accurate dry temperature reference points, which are necessary for many temperature applications such as thermocouple calibration.

  15. Thermoelectric refrigerator having improved temperature stabilization means

    DOEpatents

    Falco, Charles M.

    1982-01-01

    A control system for thermoelectric refrigerators is disclosed. The thermoelectric refrigerator includes at least one thermoelectric element that undergoes a first order change at a predetermined critical temperature. The element functions as a thermoelectric refrigerator element above the critical temperature, but discontinuously ceases to function as a thermoelectric refrigerator element below the critical temperature. One example of such an arrangement includes thermoelectric refrigerator elements which are superconductors. The transition temperature of one of the superconductor elements is selected as the temperature control point of the refrigerator. When the refrigerator attempts to cool below the point, the metals become superconductors losing their ability to perform as a thermoelectric refrigerator. An extremely accurate, first-order control is realized.

  16. Low temperature fuel behavior studies

    NASA Technical Reports Server (NTRS)

    Stockemer, F. J.

    1980-01-01

    Aircraft fuels at low temperatures near the freezing point. The principal objective was an improved understanding of the flowability and pumpability of the fuels in a facility that simulated the heat transfer and temperature profiles encountered during flight in the long range commercial wing tanks.

  17. The Effects of Natural Chinese Medicine Aconite Root, Dried Ginger Rhizome, and Coptis on Rectal and Skin Temperatures at Acupuncture Points

    PubMed Central

    Li, Gang; Wang, Min; Jin, Yi-Xi; Zhang, Shu-Jing; Wu, Meng-Yao

    2017-01-01

    The 4 properties of Chinese materia medica refer to cold, hot, warm, and cool. In the present study, the effects of the Coptis, the prepared aconite root, and dried ginger rhizome were compared with regard to the rectal and skin temperature changes of the related body surface acupuncture points (Dazhui, Zhiyang, Mingmen, Zhongwan, and Shenque). The investigation aimed to explore the thermal sensitive points, which can reflect the cold and hot properties of the Chinese herbs. This study showed that the prepared aconite root and dried ginger rhizome exhibited a warming effect on the body temperature, whereas the warming sensitive points were Zhongwan, Shenque, Dazhui, and Zhiyang. Coptis exhibited both a warming and a cooling effect on the body temperature, and the cooling sensitive point was Dazhui. The concomitant effect of these three Chinese herbs on the regulation of the body temperature was reflected by Dazhui. However, there are still some limitations and one-sidedness. For instance, the cold and hot property of some herbs cannot be fully reflected through relevant acupoints on the conception and governor vessels. More detecting sites such as ears and internal organs will be selected for further exploration of Chinese herbs' cold and hot property. PMID:29259648

  18. Visualizing Stress and Temperature Distribution During Elevated Temperature Deformation of IN-617 Using Nanomechanical Raman Spectroscopy

    NASA Astrophysics Data System (ADS)

    Zhang, Yang; Wang, Hao; Tomar, Vikas

    2018-04-01

    This work presents direct measurements of stress and temperature distribution during the mesoscale microstructural deformation of Inconel-617 (IN-617) during 3-point bending tests as a function of temperature. A novel nanomechanical Raman spectroscopy (NMRS)-based measurement platform was designed for simultaneous in situ temperature and stress mapping as a function of microstructure during deformation. The temperature distribution was found to be directly correlated to stress distribution for the analyzed microstructures. Stress concentration locations are shown to be directly related to higher heat conduction and result in microstructural hot spots with significant local temperature variation.

  19. Measuring of temperatures of phase objects using a point-diffraction interferometer plate made with the thermocavitation process

    NASA Astrophysics Data System (ADS)

    Aguilar, Juan C.; Berriel-Valdos, L. R.; Aguilar, J. Felix; Mejia-Romero, S.

    An optical system formed by four point-diffraction interferometers is used for measuring the refractive index distribution of a phase object. The phase of the object is assumed enough smooth to be computed in terms of the Radon Transform and it is processed with a tomographic iterative algorithm. Then, the associated refractive index distribution is calculated. To recovery the phase from the inteferograms we use the Kreis method, which is useful for interferograms having only few fringes. As an application of our technique, the temperature distribution of a candle flame is retrieved, this was made with the aid of the Gladstone-Dale equation. We also describe the process of manufacturing the point-diffraction interferometer (PDI) plates. These were made by means of the thermocavitation process. The obtained three dimensional distribution of temperature is presented.

  20. Automated calibration of laser spectrometer measurements of δ18 O and δ2 H values in water vapour using a Dew Point Generator.

    PubMed

    Munksgaard, Niels C; Cheesman, Alexander W; Gray-Spence, Andrew; Cernusak, Lucas A; Bird, Michael I

    2018-06-30

    Continuous measurement of stable O and H isotope compositions in water vapour requires automated calibration for remote field deployments. We developed a new low-cost device for calibration of both water vapour mole fraction and isotope composition. We coupled a commercially available dew point generator (DPG) to a laser spectrometer and developed hardware for water and air handling along with software for automated operation and data processing. We characterised isotopic fractionation in the DPG, conducted a field test and assessed the influence of critical parameters on the performance of the device. An analysis time of 1 hour was sufficient to achieve memory-free analysis of two water vapour standards and the δ 18 O and δ 2 H values were found to be independent of water vapour concentration over a range of ≈20,000-33,000 ppm. The reproducibility of the standard vapours over a 10-day period was better than 0.14 ‰ and 0.75 ‰ for δ 18 O and δ 2 H values, respectively (1 σ, n = 11) prior to drift correction and calibration. The analytical accuracy was confirmed by the analysis of a third independent vapour standard. The DPG distillation process requires that isotope calibration takes account of DPG temperature, analysis time, injected water volume and air flow rate. The automated calibration system provides high accuracy and precision and is a robust, cost-effective option for long-term field measurements of water vapour isotopes. The necessary modifications to the DPG are minor and easily reversible. Copyright © 2018 John Wiley & Sons, Ltd.

  1. Self-validating type C thermocouples to 2300 °C using high temperature fixed points

    NASA Astrophysics Data System (ADS)

    Pearce, J. V.; Elliott, C. J.; Machin, G.; Ongrai, O.

    2013-09-01

    Above 1500 °C, tungsten-rhenium (W-Re) thermocouples are the most commonly used contact thermometers because they are practical and inexpensive. However in general loss of calibration is very rapid, and, due to their embrittlement at high temperature, it is generally not possible to remove them for recalibration from the process environments in which they are used. Even if removal for recalibration was possible this would be of, at best, very limited use due to large inhomogeneity effects. Ideally, these thermocouples require some mechanism to monitor their drift in-situ. In this study, we describe self-validation of Type C (W5%Re/W26%Re) thermocouples by means of miniature high temperature fixed points comprising crucibles containing respectively Co-C, Pt-C, Ru-C, and Ir-C eutectic alloys. An overview of developments in this area is presented.

  2. Threshold temperature optical fibre sensors

    NASA Astrophysics Data System (ADS)

    Stasiewicz, K. A.; Musial, J. E.

    2016-12-01

    This paper presents a new approach to manufacture a threshold temperature sensor based on a biconical optical fibre taper. The presented sensor employs the influence of variable state of concentration of some isotropic materials like wax or paraffin. Application of the above- mentioned materials is an attempt to prove that there is a possibility to obtain a low-cost, repeatable and smart sensor working as an in-line element. Optical fibre taper was obtained from a standard single mode fibre (SMF28®) by using a low pressure gas burner technique. The diameter of the manufactured tapers was 6.0 ± 0.5 μm with the length of elongation equal to 30.50 ± 0.16 mm. The applied technology allowed to produce tapers with the losses of 0.183 ± 0.015 dB. Application of materials with different temperature transition points made it possible to obtain the threshold work at the temperatures connected directly with their conversion temperature. External materials at the temperatures above their melting points do not influence the propagation losses. For each of them two types of the protection area and position of the optical fibre taper were applied.

  3. Tests of a High Temperature Sample Conditioner for the Waste Treatment Plant LV-S2, LV-S3, HV-S3A and HV-S3B Exhaust Systems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Flaherty, Julia E.; Glissmeyer, John A.

    2015-03-18

    Tests were performed to evaluate a sample conditioning unit for stack monitoring at Hanford Tank Waste Treatment and Immobilization Plant (WTP) exhaust stacks with elevated air temperatures. The LV-S2, LV-S3, HV-S3A and HV-S3B exhaust stacks are expected to have elevated air temperature and dew point. At these emission points, exhaust temperatures are too high to deliver the air sample directly to the required stack monitoring equipment. As a result, a sample conditioning system is considered to cool and dry the air prior to its delivery to the stack monitoring system. The method proposed for the sample conditioning is a dilutionmore » system that will introduce cooler, dry air to the air sample stream. This method of sample conditioning is meant to reduce the sample temperature while avoiding condensation of moisture in the sample stream. An additional constraint is that the ANSI/HPS N13.1-1999 standard states that at least 50% of the 10 μm aerodynamic diameter (AD) particles present in the stack free stream must be delivered to the sample collector. In other words, depositional loss of particles should be limited to 50% in the sampling, transport, and conditioning systems. Based on estimates of particle penetration through the LV-S3 sampling system, the diluter should perform with about 80% penetration or better to ensure that the total sampling system passes the 50% or greater penetration criterion.« less

  4. Magnetic heat pumping near room temperature

    NASA Technical Reports Server (NTRS)

    Brown, G. V.

    1976-01-01

    It is shown that magnetic heat pumping can be made practical at room temperature by using a ferromagnetic material with a Curie point at or near operating temperature and an appropriate regenerative thermodynamic cycle. Measurements are performed which show that gadolinium is a resonable working material and it is found that the application of a 7-T magnetic field to gadolinium at the Curie point (293 K) causes a heat release of 4 kJ/kg under isothermal conditions or a temperature rise of 14 K under adiabatic conditions. A regeneration technique can be used to lift the load of the lattice and electronic heat capacities off the magnetic system in order to span a reasonable temperature difference and to pump as much entropy per cycle as possible

  5. Reorientational dynamics in molecular liquids as revealed by dynamic light scattering: from boiling point to glass transition temperature.

    PubMed

    Schmidtke, B; Petzold, N; Kahlau, R; Rössler, E A

    2013-08-28

    We determine the reorientational correlation time τ of a series of molecular liquids by performing depolarized light scattering experiments (double monochromator, Fabry-Perot interferometry, and photon correlation spectroscopy). Correlation times in the range 10(-12) s-100 s are compiled, i.e., the full temperature interval between the boiling point and the glass transition temperature T(g) is covered. We focus on low-T(g) liquids for which the high-temperature limit τ ≅ 10(-12) s is easily accessed by standard spectroscopic equipment (up to 440 K). Regarding the temperature dependence three interpolation formulae of τ(T) with three parameters each are tested: (i) Vogel-Fulcher-Tammann equation, (ii) the approach recently discussed by Mauro et al. [Proc. Natl. Acad. Sci. U.S.A. 106, 19780 (2009)], and (iii) our approach decomposing the activation energy E(T) in a constant high temperature value E∞ and a "cooperative part" E(coop)(T) depending exponentially on temperature [Schmidtke et al., Phys. Rev. E 86, 041507 (2012)]. On the basis of the present data, approaches (i) and (ii) are insufficient as they do not provide the correct crossover to the high-temperature Arrhenius law clearly identified in the experimental data while approach (iii) reproduces the salient features of τ(T). It allows to discuss the temperature dependence of the liquid's dynamics in terms of a E(coop)(T)/E∞ vs. T/E∞ plot and suggests that E∞ controls the energy scale of the glass transition phenomenon.

  6. Lightweight dew-/frost-point hygrometer based on a surface-acoustic-wave sensor for balloon-borne atmospheric water vapor profile sounding

    NASA Astrophysics Data System (ADS)

    Hansford, Graeme M.; Freshwater, Ray A.; Eden, Louise; Turnbull, Katharine F. V.; Hadaway, David E.; Ostanin, Victor P.; Jones, Roderic L.

    2006-01-01

    The design of a very lightweight dew-/frost-point hygrometer for balloon-borne atmospheric water vapor profiling is described. The instrument is based on a surface-acoustic-wave sensor. The low instrument weight is a key feature, allowing flights on meteorological balloons which brings many more flight opportunities. The hygrometer shows consistently good performance in the troposphere and while water vapor measurements near the tropopause and in the stratosphere are possible with the current instrument, the long-time response in these regions hampers realistic measurements. The excellent intrinsic sensitivity of the surface-acoustic-wave sensor should permit considerable improvement in the hygrometer performance in the very dry regions of the atmosphere.

  7. Predicting critical temperatures of ionic and non-ionic fluids from thermophysical data obtained near the melting point.

    PubMed

    Weiss, Volker C

    2015-10-14

    In the correlation and prediction of thermophysical data of fluids based on a corresponding-states approach, the critical temperature Tc plays a central role. For some fluids, in particular ionic ones, however, the critical region is difficult or even impossible to access experimentally. For molten salts, Tc is on the order of 3000 K, which makes accurate measurements a challenging task. Room temperature ionic liquids (RTILs) decompose thermally between 400 K and 600 K due to their organic constituents; this range of temperatures is hundreds of degrees below recent estimates of their Tc. In both cases, reliable methods to deduce Tc based on extrapolations of experimental data recorded at much lower temperatures near the triple or melting points are needed and useful because the critical point influences the fluid's behavior in the entire liquid region. Here, we propose to employ the scaling approach leading to universal fluid behavior [Román et al., J. Chem. Phys. 123, 124512 (2005)] to derive a very simple expression that allows one to estimate Tc from the density of the liquid, the surface tension, or the enthalpy of vaporization measured in a very narrow range of low temperatures. We demonstrate the validity of the approach for simple and polar neutral fluids, for which Tc is known, and then use the methodology to obtain estimates of Tc for ionic fluids. When comparing these estimates to those reported in the literature, good agreement is found for RTILs, whereas the ones for the molten salts NaCl and KCl are lower than previous estimates by 10%. The coexistence curve for ionic fluids is found to be more adequately described by an effective exponent of βeff = 0.5 than by βeff = 0.33.

  8. Zero-point corrections and temperature dependence of HD spin-spin coupling constants of heavy metal hydride and dihydrogen complexes calculated by vibrational averaging.

    PubMed

    Mort, Brendan C; Autschbach, Jochen

    2006-08-09

    Vibrational corrections (zero-point and temperature dependent) of the H-D spin-spin coupling constant J(HD) for six transition metal hydride and dihydrogen complexes have been computed from a vibrational average of J(HD) as a function of temperature. Effective (vibrationally averaged) H-D distances have also been determined. The very strong temperature dependence of J(HD) for one of the complexes, [Ir(dmpm)Cp*H2]2 + (dmpm = bis(dimethylphosphino)methane) can be modeled simply by the Boltzmann average of the zero-point vibrationally averaged JHD of two isomers. For this complex and four others, the vibrational corrections to JHD are shown to be highly significant and lead to improved agreement between theory and experiment in most cases. The zero-point vibrational correction is important for all complexes. Depending on the shape of the potential energy and J-coupling surfaces, for some of the complexes higher vibrationally excited states can also contribute to the vibrational corrections at temperatures above 0 K and lead to a temperature dependence. We identify different classes of complexes where a significant temperature dependence of J(HD) may or may not occur for different reasons. A method is outlined by which the temperature dependence of the HD spin-spin coupling constant can be determined with standard quantum chemistry software. Comparisons are made with experimental data and previously calculated values where applicable. We also discuss an example where a low-order expansion around the minimum of a complicated potential energy surface appears not to be sufficient for reproducing the experimentally observed temperature dependence.

  9. Stagnation Temperature Recording

    NASA Technical Reports Server (NTRS)

    Wimmer, W

    1941-01-01

    The present report deals with the development of a thermometer for recording stagnation temperature in compressible mediums in turbulent flow within 1 to 2 percent error of the adiabatic temperature in the stagnation point, depending upon the speed. This was achieved by placing the junction of a thermocouple near the stagnation point of an aerodynamically beneficial body, special care being taken to assure an uninterrupted supply of fresh compressed air on the junction together with the use of metals of low thermal conductivity, thus keeping heat-transfer and heat-dissipation losses to a minimum. In other experiments the use of the plate thermometer was proved unsuitable for practical measurements by reason of its profound influence in the reading by the Reynolds number and by the direction of flow.

  10. High-Temperature Shape Memory Polymers

    NASA Technical Reports Server (NTRS)

    Yoonessi, Mitra; Weiss, Robert A.

    2012-01-01

    physical conformation changes when exposed to an external stimulus, such as a change in temperature. Such materials have a permanent shape, but can be reshaped above a critical temperature and fixed into a temporary shape when cooled under stress to below the critical temperature. When reheated above the critical temperature (Tc, also sometimes called the triggering or switching temperature), the materials revert to the permanent shape. The current innovation involves a chemically treated (sulfonated, carboxylated, phosphonated, or other polar function group), high-temperature, semicrystalline thermoplastic poly(ether ether ketone) (Tg .140 C, Tm = 340 C) mix containing organometallic complexes (Zn++, Li+, or other metal, ammonium, or phosphonium salts), or high-temperature ionic liquids (e.g. hexafluorosilicate salt with 1-propyl-3- methyl imidazolium, Tm = 210 C) to form a network where dipolar or ionic interactions between the polymer and the low-molecular-weight or inorganic compound forms a complex that provides a physical crosslink. Hereafter, these compounds will be referred to as "additives". The polymer is semicrystalline, and the high-melt-point crystals provide a temporary crosslink that acts as a permanent crosslink just so long as the melting temperature is not exceeded. In this example case, the melting point is .340 C, and the shape memory critical temperature is between 150 and 250 C. PEEK is an engineering thermoplastic with a high Young fs modulus, nominally 3.6 GPa. An important aspect of the invention is the control of the PEEK functionalization (in this example, the sulfonation degree), and the thermal properties (i.e. melting point) of the additive, which determines the switching temperature. Because the compound is thermoplastic, it can be formed into the "permanent" shape by conventional plastics processing operations. In addition, the compound may be covalently cross - linked after forming the permanent shape by S-PEEK by applying ionizing

  11. Relationships between nocturnal winter road slipperiness, cloud cover and surface temperature

    NASA Astrophysics Data System (ADS)

    Grimbacher, T.; Schmid, W.

    2003-04-01

    Ice and Snow are important risks for road traffic. In this study we show several events of slipperiness in Switzerland, mainly caused by rain or snow falling on a frozen surface. Other reasons for slippery conditions are frost or freezing dew in clear nights and nocturnal clearing after precipitation, which goes along with radiative cooling. The main parameters of road weather forecasts are precipitation, cloudiness and surface temperature. Precipitation is well predictable with weather radars and radar nowcasting algorithms. Temperatures are often taken from numerical weather prediction models, but because of changes in cloud cover these model values are inaccurate in terms of predicting the onset of freezing. Cloudiness, especially the advection, formation and dissipation of clouds and their interaction with surface temperatures, is one of the major unsolved problems of road weather forecasts. Cloud cover and the temperature difference between air and surface temperature are important parameters of the radiation balance. In this contribution, we show the relationship between them, proved at several stations all over Switzerland. We found a quadratic correlation coefficient of typically 60% and improved it considering other meteorological parameters like wind speed and surface water. The acquired relationship may vary from one station to another, but we conclude that temperature difference is a signature for nocturnal cloudiness. We investigated nocturnal cloudiness for two cases from winters 2002 and 2003 in the canton of Lucerne in central Switzerland. There, an ultra-dense combination of two networks with together 55 stations within 50x50 km^2 is operated, measuring air and surface temperature, wind and other road weather parameters. With the aid of our equations, temperature differences detected from this network were converted into cloud maps. A comparison between precipitation seen by radar, cloud maps and surface temperatures shows that there are similar

  12. Core body temperature in obesity123

    PubMed Central

    Heikens, Marc J; Gorbach, Alexander M; Eden, Henry S; Savastano, David M; Chen, Kong Y; Skarulis, Monica C

    2011-01-01

    Background: A lower core body temperature set point has been suggested to be a factor that could potentially predispose humans to develop obesity. Objective: We tested the hypothesis that obese individuals have lower core temperatures than those in normal-weight individuals. Design: In study 1, nonobese [body mass index (BMI; in kg/m2) <30] and obese (BMI ≥30) adults swallowed wireless core temperature–sensing capsules, and we measured core temperatures continuously for 24 h. In study 2, normal-weight (BMI of 18–25) and obese subjects swallowed temperature-sensing capsules to measure core temperatures continuously for ≥48 h and kept activity logs. We constructed daily, 24-h core temperature profiles for analysis. Results: Mean (±SE) daily core body temperature did not differ significantly between the 35 nonobese and 46 obese subjects (36.92 ± 0.03°C compared with 36.89 ± 0.03°C; P = 0.44). Core temperature 24-h profiles did not differ significantly between 11 normal-weight and 19 obese subjects (P = 0.274). Women had a mean core body temperature ≈0.23°C greater than that of men (36.99 ± 0.03°C compared with 36.76 ± 0.03°C; P < 0.0001). Conclusions: Obesity is not generally associated with a reduced core body temperature. It may be necessary to study individuals with function-altering mutations in core temperature–regulating genes to determine whether differences in the core body temperature set point affect the regulation of human body weight. These trials were registered at clinicaltrials.gov as NCT00428987 and NCT00266500. PMID:21367952

  13. INNOVATIVE INSTRUMENTATION AND ANALYSIS OF THE TEMPERATURE MEASUREMENT FOR HIGH TEMPERATURE GASIFICATION

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Seong W. Lee

    2004-10-01

    The systematic tests of the gasifier simulator on the clean thermocouple were completed in this reporting period. Within the systematic tests on the clean thermocouple, five (5) factors were considered as the experimental parameters including air flow rate, water flow rate, fine dust particle amount, ammonia addition and high/low frequency device (electric motor). The fractional factorial design method was used in the experiment design with sixteen (16) data sets of readings. Analysis of Variances (ANOVA) was applied to the results from systematic tests. The ANOVA results show that the un-balanced motor vibration frequency did not have the significant impact onmore » the temperature changes in the gasifier simulator. For the fine dust particles testing, the amount of fine dust particles has significant impact to the temperature measurements in the gasifier simulator. The effects of the air and water on the temperature measurements show the same results as reported in the previous report. The ammonia concentration was included as an experimental parameter for the reducing environment in this reporting period. The ammonia concentration does not seem to be a significant factor on the temperature changes. The linear regression analysis was applied to the temperature reading with five (5) factors. The accuracy of the linear regression is relatively low, which is less than 10% accuracy. Nonlinear regression was also conducted to the temperature reading with the same factors. Since the experiments were designed in two (2) levels, the nonlinear regression is not very effective with the dataset (16 readings). An extra central point test was conducted. With the data of the center point testing, the accuracy of the nonlinear regression is much better than the linear regression.« less

  14. Remote temperature distribution sensing using permanent magnets

    DOE PAGES

    Chen, Yi; Guba, Oksana; Brooks, Carlton F.; ...

    2016-10-31

    Remote temperature sensing is essential for applications in enclosed vessels where feedthroughs or optical access points are not possible. A unique sensing method for measuring the temperature of multiple closely-spaced points is proposed using permanent magnets and several three-axis magnetic field sensors. The magnetic field theory for multiple magnets is discussed and a solution technique is presented. Experimental calibration procedures, solution inversion considerations and methods for optimizing the magnet orientations are described in order to obtain low-noise temperature estimates. The experimental setup and the properties of permanent magnets are shown. Finally, experiments were conducted to determine the temperature of ninemore » magnets in different configurations over a temperature range of 5 to 60 degrees Celsius and for a sensor-to-magnet distance of up to 35 mm. Furthermore, to show the possible applications of this sensing system for measuring temperatures through metal walls, additional experiments were conducted inside an opaque 304 stainless steel cylinder.« less

  15. Flexible Multiplexed Surface Temperature Sensor

    NASA Technical Reports Server (NTRS)

    Daryabeigi, Kamran; Dillon-Townes, L. A.; Johnson, Preston B.; Ash, Robert L.

    1995-01-01

    Unitary array of sensors measures temperatures at points distributed over designated area on surface. Useful in measuring surface temperatures of aerodynamic models and thermally controlled objects. Made of combination of integrated-circuit microchips and film circuitry. Temperature-sensing chips scanned at speeds approaching 10 kHz. Operating range minus 40 degrees C to 120 degrees C. Flexibility of array conforms to curved surfaces. Multiplexer eliminates numerous monitoring cables. Control of acquisition and recording of data effected by connecting array to microcomputers via suitable interface circuitry.

  16. Temperature Measurement Aid

    NASA Technical Reports Server (NTRS)

    1979-01-01

    NASA's Ames Research Center has designed a simple but medically important device--one which holds temperature probes, called thermistors, to a person's skin without affecting the characteristics of the skin segment being measured. The device improves the accuracy of skin surface temperature measurements, valuable data in health evaluation. The need for such a device was recognized in the course of life science experiments at Ames. In earlier methods, the sensing head of the temperature probe was affixed to the patient's skin by tape or elastic bands. This created a heat variance which altered skin temperature readings. The Ames-developed thermistor holder is a plastic ring with tab extensions, shown in the upper photo on the chest, arm and leg of the patient undergoing examination. The ring holds the sensing head of the temperature probe and provides firm, constant pressure between the skin and the probe. The tabs help stabilize the ring and provide attachment points for the fastening tape or bands, which do not directly touch the sensor. With this new tool, it is possible to determine more accurately the physiological effects of strenuous exercise, particularly on the treadmill. The holder is commercially available from Yellow Springs Instrument Company, Inc., Yellow Springs, Ohio, which is producing the device under a NASA patent license.

  17. Technical report: The design and evaluation of a basin-scale wireless sensor network for mountain hydrology

    NASA Astrophysics Data System (ADS)

    Zhang, Ziran; Glaser, Steven D.; Bales, Roger C.; Conklin, Martha; Rice, Robert; Marks, Danny G.

    2017-05-01

    A network of sensors for spatially representative water-balance measurements was developed and deployed across the 2000 km2 snow-dominated portion of the upper American River basin, primarily to measure changes in snowpack and soil-water storage, air temperature, and humidity. This wireless sensor network (WSN) consists of 14 sensor clusters, each with 10 measurement nodes that were strategically placed within a 1 km2 area, across different elevations, aspects, slopes, and canopy covers. Compared to existing operational sensor installations, the WSN reduces hydrologic uncertainty in at least three ways. First, redundant measurements improved estimation of lapse rates for air and dew-point temperature. Second, distributed measurements captured local variability and constrained uncertainty in air and dew-point temperature, snow accumulation, and derived hydrologic attributes important for modeling and prediction. Third, the distributed relative-humidity measurements offer a unique capability to monitor upper-basin patterns in dew-point temperature and characterize elevation gradient of water vapor-pressure deficit across steep, variable topography. Network statistics during the first year of operation demonstrated that the WSN was robust for cold, wet, and windy conditions in the basin. The electronic technology used in the WSN-reduced adverse effects, such as high current consumption, multipath signal fading, and clock drift, seen in previous remote WSNs.

  18. Temperature measurement systems in wearable electronics

    NASA Astrophysics Data System (ADS)

    Walczak, S.; Gołebiowski, J.

    2014-08-01

    The aim of this paper is to present the concept of temperature measurement system, adapted to wearable electronics applications. Temperature is one of the most commonly monitored factor in smart textiles, especially in sportswear, medical and rescue products. Depending on the application, measured temperature could be used as an initial value of alert, heating, lifesaving or analysis system. The concept of the temperature measurement multi-point system, which consists of flexible screen-printed resistive sensors, placed on the T-shirt connected with the central unit and the power supply is elaborated in the paper.

  19. The emissivities of liquid metals at their fusion temperatures

    NASA Technical Reports Server (NTRS)

    Bonnell, D. W.; Treverton, J. A.; Valerga, A. J.; Margrave, J. L.

    1972-01-01

    A survey of the literature through 1969 shows an almost total lack of experimental emissivity data for metals in the liquid state. The emissivities for several transition metals and various other metals and compounds in the liquid state at their fusion temperatures have been determined. The technique used involves electromagnetic levitation-induction heating of the materials in an inert atmosphere. The brightness temperature of the liquid phase of the material is measured as the material is heated through fusion. Given a reliable value of the fusion temperature, which is available for most pure substances, one may readily calculate an emissivity for the liquid phase at the fusion temperatures. Even in cases where melting points are poorly known, the brightness temperatures are unique parameters, independent of the temperature scale and measured for a chemically defined system at a fixed point. Better emissivities may be recalculated as better melting point data become available.

  20. Temperature based Restricted Boltzmann Machines

    NASA Astrophysics Data System (ADS)

    Li, Guoqi; Deng, Lei; Xu, Yi; Wen, Changyun; Wang, Wei; Pei, Jing; Shi, Luping

    2016-01-01

    Restricted Boltzmann machines (RBMs), which apply graphical models to learning probability distribution over a set of inputs, have attracted much attention recently since being proposed as building blocks of multi-layer learning systems called deep belief networks (DBNs). Note that temperature is a key factor of the Boltzmann distribution that RBMs originate from. However, none of existing schemes have considered the impact of temperature in the graphical model of DBNs. In this work, we propose temperature based restricted Boltzmann machines (TRBMs) which reveals that temperature is an essential parameter controlling the selectivity of the firing neurons in the hidden layers. We theoretically prove that the effect of temperature can be adjusted by setting the parameter of the sharpness of the logistic function in the proposed TRBMs. The performance of RBMs can be improved by adjusting the temperature parameter of TRBMs. This work provides a comprehensive insights into the deep belief networks and deep learning architectures from a physical point of view.

  1. Theoretical and testing performance of an innovative indirect evaporative chiller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jiang, Yi; Xie, Xiaoyun

    2010-12-15

    An indirect evaporative chiller is a device used to produce chilled water at a temperature between the wet bulb temperature and dew point of the outdoor air, which can be used in building HVAC systems. This article presents a theoretical analysis and practical performance of an innovative indirect evaporative chiller. First, the process of the indirect evaporative chiller is introduced; then, the matching characteristics of the process are presented and analyzed. It can be shown that the process that produces cold water by using dry air is a nearly-reversible process, so the ideal produced chilled water temperature of the indirectmore » evaporative chiller can be set close to the dew point temperature of the chiller's inlet air. After the indirect evaporative chiller was designed, simulations were done to analyze the output water temperature, the cooling efficiency relative to the inlet dew point temperature, and the COP that the chiller can performance. The first installation of the indirect evaporative chiller of this kind has been run for 5 years in a building in the city of Shihezi. The tested output water temperature of the chiller is around 14-20 C, which is just in between of the outdoor wet bulb temperature and dew point. The tested COP{sub r,s} of the developed indirect evaporative chiller reaches 9.1. Compared with ordinary air conditioning systems, the indirect evaporative chiller can save more than 40% in energy consumption due to the fact that the only energy consumed is from pumps and fans. An added bonus is that the indirect evaporative chiller uses no CFCs that pollute to the aerosphere. The tested internal parameters, such as the water-air flow rate ratio and heat transfer area for each heat transfer process inside the chiller, were analyzed and compared with designed values. The tested indoor air conditions, with a room temperature of 23-27 C and relative humidity of 50-70%, proved that the developed practical indirect evaporative chiller

  2. System for controlling the operating temperature of a fuel cell

    DOEpatents

    Fabis, Thomas R.; Makiel, Joseph M.; Veyo, Stephen E.

    2006-06-06

    A method and system are provided for improved control of the operating temperature of a fuel cell (32) utilizing an improved temperature control system (30) that varies the flow rate of inlet air entering the fuel cell (32) in response to changes in the operating temperature of the fuel cell (32). Consistent with the invention an improved temperature control system (30) is provided that includes a controller (37) that receives an indication of the temperature of the inlet air from a temperature sensor (39) and varies the heat output by at least one heat source (34, 36) to maintain the temperature of the inlet air at a set-point T.sub.inset. The controller (37) also receives an indication of the operating temperature of the fuel cell (32) and varies the flow output by an adjustable air mover (33), within a predetermined range around a set-point F.sub.set, in order to maintain the operating temperature of the fuel cell (32) at a set-point T.sub.opset.

  3. Temperature Scaling Law for Quantum Annealing Optimizers.

    PubMed

    Albash, Tameem; Martin-Mayor, Victor; Hen, Itay

    2017-09-15

    Physical implementations of quantum annealing unavoidably operate at finite temperatures. We point to a fundamental limitation of fixed finite temperature quantum annealers that prevents them from functioning as competitive scalable optimizers and show that to serve as optimizers annealer temperatures must be appropriately scaled down with problem size. We derive a temperature scaling law dictating that temperature must drop at the very least in a logarithmic manner but also possibly as a power law with problem size. We corroborate our results by experiment and simulations and discuss the implications of these to practical annealers.

  4. The effects of trace impurities in coal-derived liquid fuels on deposition and accelerated high temperature corrosion of cast superalloys

    NASA Technical Reports Server (NTRS)

    Lowell, C. E.; Deadmore, D. J.; Santoro, G. J.; Kohl, F. J.

    1981-01-01

    The effects of trace metal impurities in coal-derived liquids on deposition, high temperature corrosion and fouling were examined. Alloys were burner rig tested from 800 to 1100 C and corrosion was evaluated as a function of potential impurities. Actual and doped fuel test were used to define an empirical life prediction equation. An evaluation of inhibitors to reduce or eliminate accelerated corrosion was made. Barium and strontium were found to limit attack. Intermittent application of the inhibitors or silicon additions were found to be effective techniques for controlling deposition without losing the inhibitor benefits. A computer program was used to predict the dew points and compositions of deposits. These predictions were confirmed in deposition test. The potential for such deposits to plug cooling holes of turbine airfoils was evaluated. Tests indicated that, while a potential problem exists, it strongly depended on minor impurity variations.

  5. Quantum tricritical point in the temperature-pressure-magnetic field phase diagram of CeTiGe 3

    DOE PAGES

    Kaluarachchi, Udhara S.; Taufour, Valentin; Bud'ko, Sergey L.; ...

    2018-01-22

    We report the temperature-pressure-magnetic eld phase diagram of the ferromagnetic Kondolattice CeTiGe 3 determined by means of electrical resistivity measurements. Measurements up to ~5.8GPa reveal a rich phase diagram with multiple phase transitions. At ambient pressure, CeTiGe 3 orders ferromagnetically at T C =14 K. Application of pressure suppresses T C, but a pressure induced ferromagnetic quantum criticality is avoided by the appearance of two new successive transitions for p>4.1GPa that are probably antiferromagnetic in nature. These two transitions are suppressed under pressure, with the lower temperature phase being fully suppressed above 5.3GPa. The critical pressures for the presumed quantummore » phase transitions are p1≅4.1GPa and p2≅5.3GPa. Above 4.1GPa, application of magnetic eld shows a tricritical point evolving into a wing structure phase with a quantum tricritical point at 2.8T at 5.4GPa, where the rst order antiferromagneticferromagnetic transition changes into the second order antiferromagnetic-ferromagnetic transition.« less

  6. Cyanobacteria are confined to dewless habitats within a dew desert: Implications for past and future climate change for lithic microorganisms

    NASA Astrophysics Data System (ADS)

    Kidron, Giora J.; Starinsky, Abraham; Yaalon, Dan H.

    2014-11-01

    Although covering almost all rock outcrops around the world, little is known regarding the factors that govern the spatial distribution of lithic cyanobacteria and lichens. This is also the case in the Negev Desert, where cyanobacteria predominate on the rock outcrops of the south-facing slopes and lichens on the rock outcrops of the north-facing slopes. Hypothesizing that abiotic conditions determine their distribution, radiation, temperature, rain, dew and fog were monitored over a two-year period (2008-2010) at cyanobacteria- and lichen-dwelling habitats within a first-order drainage basin in the Negev Highlands. While non-significant differences characterized the rain amounts, substantial differences in substrate temperatures were recorded which resulted in turn in fundamental differences in the non-rainfall water regime. While dew condensed at the rock outcrops of the lichen habitat, no condensation took place at the cyanobacteria habitat. Contrary to the common belief, cyanobacteria were found to inhabit dewless habitats. As a result, cyanobacteria solely rely on rain precipitation for growth and can therefore serve as bioindicators for dewless habitats within the dewy Negev Desert. The findings may have important implications regarding Earth colonization, soil forming processes and geochemical processes following climate warming. They may explain lichen expansion and subsequent O2 increase during the mid Neoproterozoic providing indirect support for substantial photosynthetic activity and high weathering rates during this era.

  7. Measurement and correlation of jet fuel viscosities at low temperatures

    NASA Technical Reports Server (NTRS)

    Schruben, D. L.

    1985-01-01

    Apparatus and procedures were developed to measure jet fuel viscosity for eight current and future jet fuels at temperatures from ambient to near -60 C by shear viscometry. Viscosity data showed good reproducibility even at temperatures a few degrees below the measured freezing point. The viscosity-temperature relationship could be correlated by two linear segments when plotted as a standard log-log type representation (ASTM D 341). At high temperatures, the viscosity-temperature slope is low. At low temperatures, where wax precipitation is significant, the slope is higher. The breakpoint between temperature regions is the filter flow temperature, a fuel characteristic approximated by the freezing point. A generalization of the representation for the eight experimental fuels provided a predictive correlation for low-temperature viscosity, considered sufficiently accurate for many design or performance calculations.

  8. Effects of Temperature and pH on Reduction of Bacteria in a Point-of-Use Drinking Water Treatment Product for Emergency Relief

    PubMed Central

    Marois-Fiset, Jean-Thomas; Carabin, Anne; Lavoie, Audrey

    2013-01-01

    The effects of temperature and pH on the water treatment performance of a point-of-use (POU) coagulant/disinfectant product were evaluated. Cold temperatures (∼5°C) reduced the bactericidal efficiency of the product with regard to Escherichia coli and total coliform log10 reductions. PMID:23335762

  9. The emissivities of liquid metals at their fusion temperatures.

    NASA Technical Reports Server (NTRS)

    Bonnell, D. W.; Treverton, J. A.; Valerga, A. J.; Margrave , J. L.

    1972-01-01

    The emissivities for several transition metals and various other metals and compounds in the liquid state at their fusion temperatures have been determined in this laboratory. The technique used involves electromagnetic levitation-induction heating of the materials in an inert atmosphere. The brightness temperature of the liquid phase of the material is measured as the material is heated through fusion. Given a reliable value of the fusion temperature, which is available for most pure substances, one may readily calculate an emissivity for the liquid phase at the fusion temperature. Even in cases where melting points are poorly known, the brightness temperatures are unique parameters, independent of the temperature scale and measured for a chemically defined system at a fixed point.

  10. Development, solar test, and evaluation of a high-temperature air receiver for point-focusing parabolic dish applications

    NASA Technical Reports Server (NTRS)

    Hanseth, E. J.

    1981-01-01

    A high temperature solar receiver was fabricated and tested in excess of 1370 C on an 11-meter-diameter test bed concentrator at the Jet Propulsion Laboratory Parabolic Dish Test Site, Edwards, California. The 60-kilowatt thermal receiver design utilizes state-of-the-art silicon carbide honeycomb matrix panels to receive and transfer the solar energy and mullite elements for thermal buffer storage. Solar tests were conducted with indicated air exit temperatures ranging from 885 C (1625 F) to 1427 C (2600 F), mass flow rates of 75 to 105 g/sec (0.16 to 0.23 lbm/sec), and pressures up to 265 kPa absolute (38.4 psia). Estimates of efficiency are 59.7% at 1120 C (2048 F) to 80.6% at 885 C (1625 F) when aperture spillage losses are considered separately. Results are presented which demonstrate the feasibility of this innovative receiver concept for point-focusing parabolic dish applications over a wide temperature range.

  11. Method Of Dispensing Microdoses Of A Aqueous Solutions Of S Ubstances Onto A Carrier And A Device For Carrying Out Said Method

    DOEpatents

    Ershov, Gennady Moiseevich; Kirillov, Eugenii Vladislavovich; Mirzabekov, Andrei Darievich

    1999-10-05

    A method and a device for dispensing microdoses of aqueous solutions are provided, whereby the substance is transferred by the free surface end of a rodlike transferring element; the temperature of the transferring element is maintained at essentially the dew point of the ambient air during the transfer. The device may comprise a plate-like base to which are affixed a plurality of rods; the unfixed butt ends of the rods are coplanar. The device further comprises a means for maintaining the temperature of the unfixed butt ends of the rods essentially equal to the dew point of the ambient air during transfer of the aqueous substance

  12. Device of dispensing micro doses of aqueous solutions of substances onto a carrier and device for carrying out said method

    DOEpatents

    Ershow, Gennady Moiseevich; Kirillov, Evgenii Vladislavovich; Mirzabekov, Andrei Darievich

    1998-01-01

    A device for dispensing microdoses of aqueous solutions are provided, whereby the substance is transferred by the free surface end of a rodlike transferring element; the temperature of the transferring element is maintained at essentially the dew point of the ambient air during the transfer. The device may comprise a plate-like base to which are affixed a plurality of rods; the unfixed butt ends of the rods are coplanar. The device further comprises a means for maintaining the temperature of the unfixed butt ends of the rods essentially equal to the dew point of the ambient air during transfer of the aqueous substance.

  13. Temperature-viscosity models reassessed.

    PubMed

    Peleg, Micha

    2017-05-04

    The temperature effect on viscosity of liquid and semi-liquid foods has been traditionally described by the Arrhenius equation, a few other mathematical models, and more recently by the WLF and VTF (or VFT) equations. The essence of the Arrhenius equation is that the viscosity is proportional to the absolute temperature's reciprocal and governed by a single parameter, namely, the energy of activation. However, if the absolute temperature in K in the Arrhenius equation is replaced by T + b where both T and the adjustable b are in °C, the result is a two-parameter model, which has superior fit to experimental viscosity-temperature data. This modified version of the Arrhenius equation is also mathematically equal to the WLF and VTF equations, which are known to be equal to each other. Thus, despite their dissimilar appearances all three equations are essentially the same model, and when used to fit experimental temperature-viscosity data render exactly the same very high regression coefficient. It is shown that three new hybrid two-parameter mathematical models, whose formulation bears little resemblance to any of the conventional models, can also have excellent fit with r 2 ∼ 1. This is demonstrated by comparing the various models' regression coefficients to published viscosity-temperature relationships of 40% sucrose solution, soybean oil, and 70°Bx pear juice concentrate at different temperature ranges. Also compared are reconstructed temperature-viscosity curves using parameters calculated directly from 2 or 3 data points and fitted curves obtained by nonlinear regression using a larger number of experimental viscosity measurements.

  14. Measuring Systems for Thermometer Calibration in Low-Temperature Range

    NASA Astrophysics Data System (ADS)

    Szmyrka-Grzebyk, A.; Lipiński, L.; Manuszkiewicz, H.; Kowal, A.; Grykałowska, A.; Jancewicz, D.

    2011-12-01

    The national temperature standard for the low-temperature range between 13.8033 K and 273.16 K has been established in Poland at the Institute of Low Temperature and Structure Research (INTiBS). The standard consists of sealed cells for realization of six fixed points of the International Temperature Scale of 1990 (ITS-90) in the low-temperature range, an adiabatic cryostat and Isotech water and mercury triple-point baths, capsule standard resistance thermometers (CSPRT), and AC and DC bridges with standard resistors for thermometers resistance measurements. INTiBS calibrates CSPRTs at the low-temperature fixed points with uncertainties less than 1 mK. In lower temperature range—between 2.5 K and about 25 K — rhodium-iron (RhFe) resistance thermometers are calibrated by comparison with a standard which participated in the EURAMET.T-K1.1 comparison. INTiBS offers a calibration service for industrial platinum resistance thermometers and for digital thermometers between 77 K and 273 K. These types of thermometers may be calibrated at INTiBS also in a higher temperature range up to 550°C. The Laboratory of Temperature Standard at INTiBS acquired an accreditation from the Polish Centre for Accreditation. A management system according to EN ISO/IEC 17025:2005 was established at the Laboratory and presented on EURAMET QSM Forum.

  15. Corresponding states correlation for temperature dependent surface tension of normal saturated liquids

    NASA Astrophysics Data System (ADS)

    Yi, Huili; Tian, Jianxiang

    2014-07-01

    A new simple correlation based on the principle of corresponding state is proposed to estimate the temperature-dependent surface tension of normal saturated liquids. The correlation is a linear one and strongly stands for 41 saturated normal liquids. The new correlation requires only the triple point temperature, triple point surface tension and critical point temperature as input and is able to represent the experimental surface tension data for these 41 saturated normal liquids with a mean absolute average percent deviation of 1.26% in the temperature regions considered. For most substances, the temperature covers the range from the triple temperature to the one beyond the boiling temperature.

  16. Temperature impacts on deep-sea biodiversity.

    PubMed

    Yasuhara, Moriaki; Danovaro, Roberto

    2016-05-01

    Temperature is considered to be a fundamental factor controlling biodiversity in marine ecosystems, but precisely what role temperature plays in modulating diversity is still not clear. The deep ocean, lacking light and in situ photosynthetic primary production, is an ideal model system to test the effects of temperature changes on biodiversity. Here we synthesize current knowledge on temperature-diversity relationships in the deep sea. Our results from both present and past deep-sea assemblages suggest that, when a wide range of deep-sea bottom-water temperatures is considered, a unimodal relationship exists between temperature and diversity (that may be right skewed). It is possible that temperature is important only when at relatively high and low levels but does not play a major role in the intermediate temperature range. Possible mechanisms explaining the temperature-biodiversity relationship include the physiological-tolerance hypothesis, the metabolic hypothesis, island biogeography theory, or some combination of these. The possible unimodal relationship discussed here may allow us to identify tipping points at which on-going global change and deep-water warming may increase or decrease deep-sea biodiversity. Predicted changes in deep-sea temperatures due to human-induced climate change may have more adverse consequences than expected considering the sensitivity of deep-sea ecosystems to temperature changes. © 2014 Cambridge Philosophical Society.

  17. Validation and results of a scale model of dew deposition in urban environments

    NASA Astrophysics Data System (ADS)

    Richards, K.; Oke, T. R.

    2002-12-01

    There is growing interest in urban dew and its significance in questions of urban climate and air pollution deposition, but little research has been undertaken to study it. In this study, a generic, urban residential neighbourhood is modelled out-of-doors at a scale of 0.125, using three wooden houses (1.08 m tall), a concrete pavement (1.0 m in width), a grassed park (7.5 m in half-width) and several small trees (up to 1.5 m tall). The thermal inertia of each house is inflated, according to the internal thermal mass (ITM) approach, so that nocturnal surface temperatures are conserved. First-order validation was achieved through comparison with data collected at nearby full-scale sites in Vancouver, BC, Canada. Moisture accumulation (measured by blotting on grass and by lysimetry) is found to be primarily controlled by nocturnal weather conditions and the intrinsic nature of each substrate, e.g. dewfall is abundant on nights with few clouds and light winds, and on surfaces such as grass and asphalt-shingle roofs, which cool rapidly after sunset. However, these responses are modified by location effects related to the net radiation balance of the surface, which itself is strongly linked to site geometry as expressed by sky view factor and whether surfaces are isolated from heat sources. The dominant mechanism is argued to be the systematic increase in longwave radiation loss that is associated with increased sky view. Results agree with those observed at the full scale and suggest that maps of sky view factor, and knowledge of dew at an open site, can potentially be used to create maps of dew distribution in urban and other complex environments.

  18. Conserved and narrow temperature limits in alpine insects: Thermal tolerance and supercooling points of the ice-crawlers, Grylloblatta (Insecta: Grylloblattodea: Grylloblattidae).

    PubMed

    Schoville, Sean D; Slatyer, Rachel A; Bergdahl, James C; Valdez, Glenda A

    2015-07-01

    For many terrestrial species, habitat associations and range size are dependent on physiological limits, which in turn may influence large-scale patterns of species diversity. The temperature range experienced by individuals is considered to shape the breadth of the thermal niche, with species occupying temporally and/or geographically stable climates tolerating a narrow temperature range. High-elevation environments experience large temperature fluctuations, with frequent periods below 0 °C, but Grylloblatta (Grylloblattodea: Grylloblattidae) occupy climatically stable microhabitats within this region. Here we test critical thermal limits and supercooling points for five Grylloblatta populations from across a large geographic area, to examine whether the stable microhabitats of this group are associated with a narrow thermal niche and assess their capacity to tolerate cold conditions. Thermal limits are highly conserved in Grylloblatta, despite substantial genetic divergence among populations spanning 1500 m elevation and being separated by over 500 km. Further, Grylloblatta show exceptionally narrow thermal limits compared to other insect taxa with little capacity to improve cold tolerance via plasticity. In contrast, upper thermal limits were significantly depressed by cold acclimation. Grylloblatta maintain coordinated movement until they freeze, and they die upon freezing. Convergence of the critical thermal minima, supercooling point and lower lethal limits point to adaptation to a cold but, importantly, constant thermal environment. These physiological data provide an explanation for the high endemism and patchy distribution of Grylloblatta, which relies on subterranean retreats to accommodate narrow thermal limits. These retreats are currently buffered from temperature fluctuations by snow cover, and a declining snowpack thus places Grylloblatta at risk of exposure to temperatures beyond its tolerance capacity. Copyright © 2015 Elsevier Ltd. All rights

  19. Determining noise temperatures in beam waveguide systems

    NASA Technical Reports Server (NTRS)

    Imbriale, W.; Veruttipong, W.; Otoshi, T.; Franco, M.

    1994-01-01

    A new 34-m research and development antenna was fabricated and tested as a precursor to introducing beam waveguide (BWG) antennas and Ka-band (32 GHz) frequencies into the NASA/JPL Deep Space Network. For deep space use, system noise temperature is a critical parameter. There are thought to be two major contributors to noise temperature in a BWG system: the spillover past the mirrors, and the conductivity loss in the walls. However, to date, there are no generally accepted methods for computing noise temperatures in a beam waveguide system. An extensive measurement program was undertaken to determine noise temperatures in such a system along with a correspondent effort in analytic prediction. Utilizing a very sensitive radiometer, noise temperature measurements were made at the Cassegrain focus, an intermediate focal point, and the focal point in the basement pedestal room. Several different horn diameters were used to simulate different amounts of spillover past the mirrors. Two analytic procedures were developed for computing noise temperature, one utilizing circular waveguide modes and the other a semiempirical approach. The results of both prediction methods are compared to the experimental data.

  20. Automated High-Temperature Hall-Effect Apparatus

    NASA Technical Reports Server (NTRS)

    Parker, James B.; Zoltan, Leslie D.

    1992-01-01

    Automated apparatus takes Hall-effect measurements of specimens of thermoelectric materials at temperatures from ambient to 1,200 K using computer control to obtain better resolution of data and more data points about three times as fast as before. Four-probe electrical-resistance measurements taken in 12 electrical and 2 magnetic orientations to characterize specimens at each temperature. Computer acquires data, and controls apparatus via three feedback loops: one for temperature, one for magnetic field, and one for electrical-potential data.

  1. Association between weather conditions and the number of patients at the emergency room in an Argentine hospital

    NASA Astrophysics Data System (ADS)

    Rusticucci, Matilde; Bettolli, Laura M.; de los Angeles Harris, M.

    2002-02-01

    The aim of this paper is to study the relationships between hospital emergencies and weather conditions by analysing summer and winter cases of patients requiring attention at the emergency room of a hospital in the city of Buenos Aires, Argentina. Hospital data have been sorted into seven different diagnostic groups as follows: (1) respiratory, cardiovascular and chest-pain complaints; (2) digestive, genitourinary and abdominal complaints; (3) neurological and psychopathological disorders; (4) infections; (5) contusion and crushing, bone and muscle complaints; (6) skin and allergies and (7) miscellaneous complaints. In general, there is an increase of 16.7% in winter while, for group 2 and group 6, there are more patients in summer, 54% and 75% respectively. In summer, the total number of patients for group 6 shows a significant positive correlation with temperature and dew-point temperature, and a negative correlation with the sea-level pressure for the same day. In winter, the same relationship exists, however its correlation is not as strong. The lags observed between these three variables: maximum dew-point temperature, maximum temperature, minimum air pressure and the peaks in admissions are 1, 2 and 4 days respectively. In winter, increases in temperature and dew point and decreases in pressure are followed by a peak in admissions for group 2. In winter, there are significantly more cases in group 5 on warm, dry days and on warm, wet days in the summer.

  2. Photosynthesis of the cyanobacterial soil-crust lichen Collema tenax from arid lands in southern Utah, USA: Role of water content on light and temperature responses of CO2 exchange

    USGS Publications Warehouse

    Lange, Otto L.; Belnap, Jayne; Reichenberger, H.

    1998-01-01

    1. The gelatinous cyanobacterial Collema tenax is a dominant lichen of biotic soil crusts in the western United States. In laboratory experiments, we studied CO2 exchange of this species as dependent on water content (WC), light and temperature. Results are compared with performance of green-algal lichens of the same site investigated earlier.2. As compared with published data, photosynthetic capacity of C. tenax is higher than that of other cyanobacterial and green-algal soil-crust species studied. At all temperatures and photon flux densities of ecological relevance, net photosynthesis (NP) shows a strong depression at high degrees of hydration; maximal apparent quantum-use efficiency of CO2 fixation is also reduced. Water requirements (moisture compensation point, WC for maximal NP) are higher than that of the green-algal lichens. Collema tenax exhibits extreme ‘sun plant’ features and is adapted to high thallus temperatures.3. Erratic rain showers are the main source of moisture for soil crusts on the Colorado Plateau, quickly saturating the lichens with liquid water. High water-holding capacity of C. tenax ensures extended phases of favourable hydration at conditions of high light and temperature after the rain for substantial photosynthetic production. Under such conditions the cyanobacterial lichen appears superior over its green-algal competitors, which seem better adapted to habitats with high air humidity, dew or fog as prevailing source of moisture.

  3. FIRE_CI2_KINGAIR_IWC

    Atmospheric Science Data Center

    2015-11-25

    ... Dew/Frost Point Temperature Diffusional Growth Rate Ice Water Concent Particle Diameter Particle Number Concentration Precipitation Rate Radar Reflectivity Relative Humidity Static Pressure Vertical ...

  4. FIRE_CI2_CITATN_IWC

    Atmospheric Science Data Center

    2015-11-25

    ... Dew/Frost Point Temperature Diffusional Growth Rate Ice Water Content Particle Diameter Particle Number Concentration Precipitation Rate Radar Reflectivity Relative Humidity Static Pressure Vertical ...

  5. FIRE_CI2_SABRLNR_IWC

    Atmospheric Science Data Center

    2015-11-25

    ... Dew/Frost Point Temperature Diffusional Growth Rate Ice Water Content Particle Diameter Particle Number Concentration Preciptiation Rate Radar Reflectivity Relative Humidity Static Pressure Vertical ...

  6. ASRDI oxygen technology survey. Volume 4: Low temperature measurement

    NASA Technical Reports Server (NTRS)

    Sparks, L. L.

    1974-01-01

    Information is presented on temperature measurement between the triple point and critical point of liquid oxygen. The criterion selected is that all transducers which may reasonably be employed in the liquid oxygen (LO2) temperature range are considered. The temperature range for each transducer is the appropriate full range for the particular thermometer. The discussion of each thermometer or type of thermometer includes the following information: (1) useful temperature range, (2) general and particular methods of construction and the advantages of each type, (3) specifications (accuracy, reproducibility, response time, etc.), (4) associated instrumentation, (5) calibrations and procedures, and (6) analytical representations.

  7. The Microwave Temperature Profiler (PERF)

    NASA Technical Reports Server (NTRS)

    Lim, Boon; Mahoney, Michael; Haggerty, Julie; Denning, Richard

    2013-01-01

    The JPL developed Microwave Temperature Profiler (MTP) has recently participated in GloPac, HIPPO (I to V) and TORERO, and the ongoing ATTREX campaigns. The MTP is now capable of supporting the NASA Global Hawk and a new canister version supports the NCAR G-V. The primary product from the MTP is remote measurements of the atmospheric temperature at, above and below the flight path, providing for the vertical state of the atmosphere. The NCAR-MTP has demonstrated unprecedented instrument performance and calibration with plus or minus 0.2 degrees Kelvin flight level temperature error. Derived products include curtain plots, isentropes, lapse rate, cold point height and tropopause height.

  8. Simulation of temperature field for temperature-controlled radio frequency ablation using a hyperbolic bioheat equation and temperature-varied voltage calibration: a liver-mimicking phantom study.

    PubMed

    Zhang, Man; Zhou, Zhuhuang; Wu, Shuicai; Lin, Lan; Gao, Hongjian; Feng, Yusheng

    2015-12-21

    This study aims at improving the accuracy of temperature simulation for temperature-controlled radio frequency ablation (RFA). We proposed a new voltage-calibration method in the simulation and investigated the feasibility of a hyperbolic bioheat equation (HBE) in the RFA simulation with longer durations and higher power. A total of 40 RFA experiments was conducted in a liver-mimicking phantom. Four mathematical models with multipolar electrodes were developed by the finite element method in COMSOL software: HBE with/without voltage calibration, and the Pennes bioheat equation (PBE) with/without voltage calibration. The temperature-varied voltage calibration used in the simulation was calculated from an experimental power output and temperature-dependent resistance of liver tissue. We employed the HBE in simulation by considering the delay time τ of 16 s. First, for simulations by each kind of bioheat equation (PBE or HBE), we compared the differences between the temperature-varied voltage-calibration and the fixed-voltage values used in the simulations. Then, the comparisons were conducted between the PBE and the HBE in the simulations with temperature-varied voltage calibration. We verified the simulation results by experimental temperature measurements on nine specific points of the tissue phantom. The results showed that: (1) the proposed voltage-calibration method improved the simulation accuracy of temperature-controlled RFA for both the PBE and the HBE, and (2) for temperature-controlled RFA simulation with the temperature-varied voltage calibration, the HBE method was 0.55 °C more accurate than the PBE method. The proposed temperature-varied voltage calibration may be useful in temperature field simulations of temperature-controlled RFA. Besides, the HBE may be used as an alternative in the simulation of long-duration high-power RFA.

  9. Crowdsourcing urban air temperatures from smartphone battery temperatures

    NASA Astrophysics Data System (ADS)

    Overeem, Aart; Robinson, James C. R.; Leijnse, Hidde; Steeneveld, Gert-Jan; Horn, Berthold K. P.; Uijlenhoet, Remko

    2014-05-01

    Accurate air temperature observations in urban areas are important for meteorology and energy demand planning. They are indispensable to study the urban heat island effect and the adverse effects of high temperatures on human health. However, the availability of temperature observations in cities is often limited. Here we show that relatively accurate air temperature information for the urban canopy layer can be obtained from an alternative, nowadays omnipresent source: smartphones. In this study, battery temperatures were collected by an Android application for smartphones. It has been shown that a straightforward heat transfer model can be employed to estimate daily mean air temperatures from smartphone battery temperatures for eight major cities around the world. The results demonstrate the enormous potential of this crowdsourcing application for real-time temperature monitoring in densely populated areas. Battery temperature data were collected by users of an Android application for cell phones (opensignal.com). The application automatically sends battery temperature data to a server for storage. In this study, battery temperatures are averaged in space and time to obtain daily averaged battery temperatures for each city separately. A regression model, which can be related to a physical model, is employed to retrieve daily air temperatures from battery temperatures. The model is calibrated with observed air temperatures from a meteorological station of an airport located in or near the city. Time series of air temperatures are obtained for each city for a period of several months, where 50% of the data is for independent verification. The methodology has been applied to Buenos Aires, London, Los Angeles, Paris, Mexico City, Moscow, Rome, and Sao Paulo. The evolution of the retrieved air temperatures often correspond well with the observed ones. The mean absolute error of daily air temperatures is less than 2 degrees Celsius, and the bias is within 1 degree

  10. Realization of the Temperature Scale in the Range from 234.3 K (Hg Triple Point) to 1084.62°C (Cu Freezing Point) in Croatia

    NASA Astrophysics Data System (ADS)

    Zvizdic, Davor; Veliki, Tomislav; Grgec Bermanec, Lovorka

    2008-06-01

    This article describes the realization of the International Temperature Scale in the range from 234.3 K (mercury triple point) to 1084.62°C (copper freezing point) at the Laboratory for Process Measurement (LPM), Faculty of Mechanical Engineering and Naval Architecture (FSB), University of Zagreb. The system for the realization of the ITS-90 consists of the sealed fixed-point cells (mercury triple point, water triple point and gallium melting point) and the apparatus designed for the optimal realization of open fixed-point cells which include the gallium melting point, tin freezing point, zinc freezing point, aluminum freezing point, and copper freezing point. The maintenance of the open fixed-point cells is described, including the system for filling the cells with pure argon and for maintaining the pressure during the realization.

  11. A Precise Calibration Technique for Measuring High Gas Temperatures

    NASA Technical Reports Server (NTRS)

    Gokoglu, Suleyman A.; Schultz, Donald F.

    2000-01-01

    A technique was developed for direct measurement of gas temperatures in the range of 2050 K 2700 K with improved accuracy and reproducibility. The technique utilized the low-emittance of certain fibrous materials, and the uncertainty of the technique was United by the uncertainty in the melting points of the materials, i.e., +/-15 K. The materials were pure, thin, metal-oxide fibers whose diameters varied from 60 microns to 400 microns in the experiments. The sharp increase in the emittance of the fibers upon melting was utilized as indication of reaching a known gas temperature. The accuracy of the technique was confirmed by both calculated low emittance values of transparent fibers, of order 0.01, up to a few degrees below their melting point and by the fiber-diameter independence of the results. This melting-point temperature was approached by increments not larger than 4 K, which was accomplished by controlled increases of reactant flow rates in hydrogen-air and/or hydrogen-oxygen flames. As examples of the applications of the technique, the gas-temperature measurements were used: (a) for assessing the uncertainty in inferring gas temperatures from thermocouple measurements, and (b) for calibrating an IR camera to measure gas temperatures. The technique offers an excellent calibration reference for other gas-temperature measurement methods to improve their accuracy and reliably extending their temperature range of applicability.

  12. A Precise Calibration Technique for Measuring High Gas Temperatures

    NASA Technical Reports Server (NTRS)

    Gokoglu, Suleyman A.; Schultz, Donald F.

    1999-01-01

    A technique was developed for direct measurement of gas temperatures in the range of 2050 K - 2700 K with improved accuracy and reproducibility. The technique utilized the low-emittance of certain fibrous Materials, and the uncertainty of the technique was limited by the uncertainty in the melting points of the materials, i.e., +/- 15 K. The materials were pure, thin, metal-oxide fibers whose diameters varied from 60 mm to 400 mm in the experiments. The sharp increase in the emittance of the fibers upon melting was utilized as indication of reaching a known gas temperature. The accuracy of the technique was confirmed by both calculated low emittance values of transparent fibers, of order 0.01, up to a few degrees below their melting point and by the fiber-diameter independence of the results. This melting-point temperature was approached by increments not larger than 4 K, which was accomplished by controlled increases of reactant flow rates in hydrogen-air and/or hydrogen- oxygen flames. As examples of the applications of the technique, the gas-temperature measurements were used (a) for assessing the uncertainty in infering gas temperatures from thermocouple measurements, and (b) for calibrating an IR camera to measure gas temperatures. The technique offers an excellent calibration reference for other gas-temperature measurement methods to improve their accuracy and reliably extending their temperature range of applicability.

  13. Pilot Comparison of Radiance Temperature Scale Realization Between NIMT and NMIJ

    NASA Astrophysics Data System (ADS)

    Keawprasert, T.; Yamada, Y.; Ishii, J.

    2015-03-01

    A pilot comparison of radiance temperature scale realizations between the National Institute of Metrology Thailand (NIMT) and the National Metrology Institute of Japan (NMIJ) was conducted. At the two national metrology institutes (NMIs), a 900 nm radiation thermometer, used as the transfer artifact, was calibrated by a means of a multiple fixed-point method using the fixed-point blackbody of Zn, Al, Ag, and Cu points, and by means of relative spectral responsivity measurements according to the International Temperature Scale of 1990 (ITS-90) definition. The Sakuma-Hattori equation is used for interpolating the radiance temperature scale between the four fixed points and also for extrapolating the ITS-90 temperature scale to 2000 C. This paper compares the calibration results in terms of fixed-point measurements, relative spectral responsivity, and finally the radiance temperature scale. Good agreement for the fixed-point measurements was found in case a correction for the change of the internal temperature of the artifact was applied using the temperature coefficient measured at the NMIJ. For the realized radiance temperature range from 400 C to 1100 C, the resulting scale differences between the two NMIs are well within the combined scale comparison uncertainty of 0.12 C (). The resulting spectral responsivity measured at the NIMT has a comparable curve to that measured at the NMIJ especially in the out-of-band region, yielding a ITS-90 scale difference within 1.0 C from the Cu point to 2000 C, whereas the realization comparison uncertainty of NIMT and NMIJ combined is 1.2 C () at 2000 C.

  14. Process analytical technology (PAT) approach to the formulation of thermosensitive protein-loaded pellets: Multi-point monitoring of temperature in a high-shear pelletization.

    PubMed

    Kristó, Katalin; Kovács, Orsolya; Kelemen, András; Lajkó, Ferenc; Klivényi, Gábor; Jancsik, Béla; Pintye-Hódi, Klára; Regdon, Géza

    2016-12-01

    In the literature there are some publications about the effect of impeller and chopper speeds on product parameters. However, there is no information about the effect of temperature. Therefore our main aim was the investigation of elevated temperature and temperature distribution during pelletization in a high shear granulator according to process analytical technology. During our experimental work, pellets containing pepsin were formulated with a high-shear granulator. A specially designed chamber (Opulus Ltd.) was used for pelletization. This chamber contained four PyroButton-TH® sensors built in the wall and three PyroDiff® sensors 1, 2 and 3cm from the wall. The sensors were located in three different heights. The impeller and chopper speeds were set on the basis of 3 2 factorial design. The temperature was measured continuously in 7 different points during pelletization and the results were compared with the temperature values measured by the thermal sensor of the high-shear granulator. The optimization parameters were enzyme activity, average size, breaking hardness, surface free energy and aspect ratio. One of the novelties was the application of the specially designed chamber (Opulus Ltd.) for monitoring the temperature continuously in 7 different points during high-shear granulation. The other novelty of this study was the evaluation of the effect of temperature on the properties of pellets containing protein during high-shear pelletization. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Temperature, concentration, and frequency dependence of the dielectric constant near the critical point of the binary liquid mixture nitrobenzene-tetradecane

    NASA Astrophysics Data System (ADS)

    Leys, Jan; Losada-Pérez, Patricia; Cordoyiannis, George; Cerdeiriña, Claudio A.; Glorieux, Christ; Thoen, Jan

    2010-03-01

    Detailed results are reported for the dielectric constant ɛ as a function of temperature, concentration, and frequency near the upper critical point of the binary liquid mixture nitrobenzene-tetradecane. The data have been analyzed in the context of the recently developed concept of complete scaling. It is shown that the amplitude of the low frequency critical Maxwell-Wagner relaxation (with a relaxation frequency around 10 kHz) along the critical isopleth is consistent with the predictions of a droplet model for the critical fluctuations. The temperature dependence of ɛ in the homogeneous phase can be well described with a combination of a (1-α) power law term (with α the heat capacity critical exponent) and a linear term in reduced temperature with the Ising value for α. For the proper description of the temperature dependence of the difference Δɛ between the two coexisting phases below the critical temperature, it turned out that good fits with the Ising value for the order parameter exponent β required the addition of a corrections-to-scaling contribution or a linear term in reduced temperature. Good fits to the dielectric diameter ɛd require a (1-α) power law term, a 2β power law term (in the past considered as spurious), and a linear term in reduced temperature, consistent with complete scaling.

  16. Thermodynamic Temperatures of the Triple Points of Mercury and Gallium and in the Interval 217 K to 303 K

    PubMed Central

    Moldover, M. R.; Boyes, S. J.; Meyer, C. W.; Goodwin, A. R. H.

    1999-01-01

    We measured the acoustic resonance frequencies of an argon-filled spherical cavity and the microwave resonance frequencies of the same cavity when evacuated. The microwave data were used to deduce the thermal expansion of the cavity and the acoustic data were fitted to a temperature-pressure surface to deduce zero-pressure speed-of-sound ratios. The ratios determine (T–T90), the difference between the Kelvin thermodynamic temperature T and the temperature on the International Temperature Scale of 1990 (ITS-90). The acoustic data fall on six isotherms: 217.0950 K, 234.3156 K, 253.1500 K, 273.1600 K, 293.1300 K, and 302.9166 K and the standard uncertainties of (T−T90) average 0.6 mK, depending mostly upon the model fitted to the acoustic data. Without reference to ITS-90, the data redetermine the triple point of gallium Tg and the mercury point Tm with the results: Tg/Tw = (1.108 951 6 ± 0.000 002 6) and Tm/Tw= (0.857 785 5 ± 0.000 002 0), where Tw = 273.16 K exactly. (All uncertainties are expressed as standard uncertainties.) The resonator was the same one that had been used to redetermine both the universal gas constant R, and Tg. However, the present value of Tg is (4.3 ± 0.8) mK larger than that reported earlier. We suggest that the earlier redetermination of Tg was erroneous because a virtual leak within the resonator contaminated the argon used at Tg in that work. This suggestion is supported by new acoustic data taken when the resonator was filled with xenon. Fortunately, the virtual leak did not affect the redetermination of R. The present work results in many suggestions for improving primary acoustic thermometry to achieve sub-millikelvin uncertainties over a wide temperature range.

  17. Branching points in the low-temperature dipolar hard sphere fluid

    NASA Astrophysics Data System (ADS)

    Rovigatti, Lorenzo; Kantorovich, Sofia; Ivanov, Alexey O.; Tavares, José Maria; Sciortino, Francesco

    2013-10-01

    In this contribution, we investigate the low-temperature, low-density behaviour of dipolar hard-sphere (DHS) particles, i.e., hard spheres with dipoles embedded in their centre. We aim at describing the DHS fluid in terms of a network of chains and rings (the fundamental clusters) held together by branching points (defects) of different nature. We first introduce a systematic way of classifying inter-cluster connections according to their topology, and then employ this classification to analyse the geometric and thermodynamic properties of each class of defects, as extracted from state-of-the-art equilibrium Monte Carlo simulations. By computing the average density and energetic cost of each defect class, we find that the relevant contribution to inter-cluster interactions is indeed provided by (rare) three-way junctions and by four-way junctions arising from parallel or anti-parallel locally linear aggregates. All other (numerous) defects are either intra-cluster or associated to low cluster-cluster interaction energies, suggesting that these defects do not play a significant part in the thermodynamic description of the self-assembly processes of dipolar hard spheres.

  18. ASSESSMENT of POTENTIAL CARBON DIOXIDE-BASED DEMAND CONTROL VENTILATION SYSTEM PERFORMANCE in SINGLE ZONE SYSTEMS

    DTIC Science & Technology

    2013-03-21

    and timers use a time-based estimate to predict how many people are in a facility at a given point in the day. CO2-based DCV systems measure CO2...energy and latent energy from the outside air when the coils’ surface temperature is below the dew point of the air passing over the coils (ASHRAE...model assumes that the dew point water saturation pressure is the same as the dry-bulb water vapor pressure, consistent with a typical ASHRAE

  19. Methods for Melting Temperature Calculation

    NASA Astrophysics Data System (ADS)

    Hong, Qi-Jun

    Melting temperature calculation has important applications in the theoretical study of phase diagrams and computational materials screenings. In this thesis, we present two new methods, i.e., the improved Widom's particle insertion method and the small-cell coexistence method, which we developed in order to capture melting temperatures both accurately and quickly. We propose a scheme that drastically improves the efficiency of Widom's particle insertion method by efficiently sampling cavities while calculating the integrals providing the chemical potentials of a physical system. This idea enables us to calculate chemical potentials of liquids directly from first-principles without the help of any reference system, which is necessary in the commonly used thermodynamic integration method. As an example, we apply our scheme, combined with the density functional formalism, to the calculation of the chemical potential of liquid copper. The calculated chemical potential is further used to locate the melting temperature. The calculated results closely agree with experiments. We propose the small-cell coexistence method based on the statistical analysis of small-size coexistence MD simulations. It eliminates the risk of a metastable superheated solid in the fast-heating method, while also significantly reducing the computer cost relative to the traditional large-scale coexistence method. Using empirical potentials, we validate the method and systematically study the finite-size effect on the calculated melting points. The method converges to the exact result in the limit of a large system size. An accuracy within 100 K in melting temperature is usually achieved when the simulation contains more than 100 atoms. DFT examples of Tantalum, high-pressure Sodium, and ionic material NaCl are shown to demonstrate the accuracy and flexibility of the method in its practical applications. The method serves as a promising approach for large-scale automated material screening in which

  20. Solar wind proton temperature-velocity relationship

    NASA Technical Reports Server (NTRS)

    Lopez, R. E.; Freeman, J. W.

    1986-01-01

    Helios 1 data are analyzed to find an experimental fit for the temperature-velocity relationship at 1 AU. It is shown that the proton temperature-velocity changes at a velocity of approximately 500 km/s. Interplanetary dynamic processes, i.e., stream interactions, are shown to affect the temperature-velocity relationships less than 22 percent; the functional form of these relationships appears to be preserved throughout the solar cycle. It is pointed out that any comprehensive model of the solar wind will have to address the difference in the temperature-velocity relationship between the low- and high-speed wind, since this is a product of the acceleration and subsequent heating process generating the solar wind.

  1. A universal reduced glass transition temperature for liquids

    NASA Technical Reports Server (NTRS)

    Fedors, R. F.

    1979-01-01

    Data on the dependence of the glass transition temperature on the molecular structure for low-molecular-weight liquids are analyzed in order to determine whether Boyer's reduced glass transition temperature (1952) is a universal constant as proposed. It is shown that the Boyer ratio varies widely depending on the chemical nature of the molecule. It is pointed out that a characteristic temperature ratio, defined by the ratio of the sum of the melting temperature and the boiling temperature to the sum of the glass transition temperature and the boiling temperature, is a universal constant independent of the molecular structure of the liquid. The average value of the ratio obtained from data for 65 liquids is 1.15.

  2. MEMS temperature scanner: principles, advances, and applications

    NASA Astrophysics Data System (ADS)

    Otto, Thomas; Saupe, Ray; Stock, Volker; Gessner, Thomas

    2010-02-01

    Contactless measurement of temperatures has gained enormous significance in many application fields, ranging from climate protection over quality control to object recognition in public places or military objects. Thereby measurement of linear or spatially temperature distribution is often necessary. For this purposes mostly thermographic cameras or motor driven temperature scanners are used today. Both are relatively expensive and the motor drive devices are limited regarding to the scanning rate additionally. An economic alternative are temperature scanner devices based on micro mirrors. The micro mirror, attached in a simple optical setup, reflects the emitted radiation from the observed heat onto an adapted detector. A line scan of the target object is obtained by periodic deflection of the micro scanner. Planar temperature distribution will be achieved by perpendicularly moving the target object or the scanner device. Using Planck radiation law the temperature of the object is calculated. The device can be adapted to different temperature ranges and resolution by using different detectors - cooled or uncooled - and parameterized scanner parameters. With the basic configuration 40 spatially distributed measuring points can be determined with temperatures in a range from 350°C - 1000°C. The achieved miniaturization of such scanners permits the employment in complex plants with high building density or in direct proximity to the measuring point. The price advantage enables a lot of applications, especially new application in the low-price market segment This paper shows principle, setup and application of a temperature measurement system based on micro scanners working in the near infrared range. Packaging issues and measurement results will be discussed as well.

  3. FIRE_ACE_UWCV580_UWA

    Atmospheric Science Data Center

    2017-04-26

    ... of Washington CV-580 Instrument:  Platinum resistance Chilled mirror Particle Measuring Systems Electron ... Search Parameters:  Pressure Temperature Dew point Humidity Turbulence Liquid water content ...

  4. Crowdsourcing urban air temperatures from smartphone battery temperatures

    NASA Astrophysics Data System (ADS)

    Overeem, A.; Robinson, J. C. R.; Leijnse, H.; Steeneveld, G. J.; Horn, B. K. P.; Uijlenhoet, R.

    2013-08-01

    Accurate air temperature observations in urban areas are important for meteorology and energy demand planning. They are indispensable to study the urban heat island effect and the adverse effects of high temperatures on human health. However, the availability of temperature observations in cities is often limited. Here we show that relatively accurate air temperature information for the urban canopy layer can be obtained from an alternative, nowadays omnipresent source: smartphones. In this study, battery temperatures were collected by an Android application for smartphones. A straightforward heat transfer model is employed to estimate daily mean air temperatures from smartphone battery temperatures for eight major cities around the world. The results demonstrate the enormous potential of this crowdsourcing application for real-time temperature monitoring in densely populated areas.

  5. HOT PRESSING WITH A TEMPERATURE GRADIENT

    DOEpatents

    Hausner, H.H.

    1958-05-20

    A method is described for producing powder metal compacts with a high length to width ratio, which are of substantially uniform density. The process consists in arranging a heating coil around the die and providing a temperature gradient along the length of the die with the highest temperature at the point of the compact farthest away from the ram or plunger.

  6. Selection for the best ETS (error, trend, seasonal) model to forecast weather in the Aceh Besar District

    NASA Astrophysics Data System (ADS)

    Amora Jofipasi, Chesilia; Miftahuddin; Hizir

    2018-05-01

    Weather is a phenomenon that occurs in certain areas that indicate a change in natural activity. Weather can be predicted using data in previous periods over a period. The purpose of this study is to get the best ETS model to predict the weather in Aceh Besar. The ETS model is a time series univariate forecasting method; its use focuses on trend and seasonal components. The data used are air temperature, dew point, sea level pressure, station pressure, visibility, wind speed, and sea surface temperature from January 2006 to December 2016. Based on AIC, AICc and BIC the smallest values obtained the conclusion that the ETS (M, N, A) is used to predict air temperature, and sea surface temperature, ETS (A, N, A) is used to predict dew point, sea level pressure and station pressure, ETS (A, A, N) is used to predict visibility, and ETS (A, N, N) is used to predict wind speed.

  7. Modeling Air Temperature/Water Temperature Relations Along a Small Mountain Stream Under Increasing Urban Influence

    NASA Astrophysics Data System (ADS)

    Fedders, E. R.; Anderson, W. P., Jr.; Hengst, A. M.; Gu, C.

    2017-12-01

    Boone Creek is a headwater stream of low to moderate gradient located in Boone, North Carolina, USA. Total impervious surface coverage in the 5.2 km2 catchment drained by the 1.9 km study reach increases from 13.4% in the upstream half of the reach to 24.3% in the downstream half. Other markers of urbanization, including culverting, lack of riparian shade vegetation, and bank armoring also increase downstream. Previous studies have shown the stream to be prone to temperature surges on short timescales (minutes to hours) caused by summer runoff from the urban hardscaping. This study investigates the effects of urbanization on the stream's thermal regime at daily to yearly timescales. To do this, we developed an analytical model of daily average stream temperatures based on daily average air temperatures. We utilized a two-part model comprising annual and biannual components and a daily component consisting of a 3rd-order Markov process in order to fit the thermal dynamics of our small, gaining stream. Optimizing this model at each of our study sites in each studied year (78 total site-years of data) yielded annual thermal exchange coefficients (K) for each site. These K values quantify the strength of the relationship between stream and air temperature, or inverse thermal stability. In a uniform, pristine catchment environment, K values are expected to decrease downstream as the stream gains discharge volume and, therefore, thermal inertia. Interannual average K values for our study reach, however, show an overall increase from 0.112 furthest upstream to 0.149 furthest downstream, despite a near doubling of stream discharge between these monitoring points. K values increase only slightly in the upstream, less urban, half of the reach. A line of best fit through these points on a plot of reach distance versus K value has a slope of 2E-6. But the K values of downstream, more urbanized sites increase at a rate of 2E-5 per meter of reach distance, an order of magnitude

  8. Extreme temperature packaging: challenges and opportunities

    NASA Astrophysics Data System (ADS)

    Johnson, R. Wayne

    2016-05-01

    Consumer electronics account for the majority of electronics manufactured today. Given the temperature limits of humans, consumer electronics are typically rated for operation from -40°C to +85°C. Military applications extend the range to -65°C to +125°C while underhood automotive electronics may see +150°C. With the proliferation of the Internet of Things (IoT), the goal of instrumenting (sensing, computation, transmission) to improve safety and performance in high temperature environments such as geothermal wells, nuclear reactors, combustion chambers, industrial processes, etc. requires sensors, electronics and packaging compatible with these environments. Advances in wide bandgap semiconductors (SiC and GaN) allow the fabrication of high temperature compatible sensors and electronics. Integration and packaging of these devices is required for implementation into actual applications. The basic elements of packaging are die attach, electrical interconnection and the package or housing. Consumer electronics typically use conductive adhesives or low melting point solders for die attach, wire bonds or low melting solder for electrical interconnection and epoxy for the package. These materials melt or decompose in high temperature environments. This paper examines materials and processes for high temperature packaging including liquid transient phase and sintered nanoparticle die attach, high melting point wires for wire bonding and metal and ceramic packages. The limitations of currently available solutions will also be discussed.

  9. FIRE_AX_UW_C131A

    Atmospheric Science Data Center

    2015-11-25

    ... Hot-Wire Hygrometer RMS Pressure Var Platinum Resistance Pyranometer Radiometer Reverse Flow Spatial ... Parameters:  Condensation Nuclei Dew/Frost Point Temperature Droplet Concentration Humidity Irradiance Liquid Water ...

  10. High-temperature fusion of a multielectron leviton

    NASA Astrophysics Data System (ADS)

    Moskalets, Michael

    2018-04-01

    The state of electrons injected onto the surface of the Fermi sea depends on temperature. The state is pure at zero temperature and is mixed at finite temperature. In the case of a single-electron injection, such a transformation can be detected as a decrease in shot noise with increasing temperature. In the case of a multielectron injection, the situation is subtler. The mixedness helps the development of quantum-mechanical exchange correlations between injected electrons, even if such correlations are absent at zero temperature. These correlations enhance the shot noise, which in part counteracts the reduction of noise with temperature. Moreover, at sufficiently high temperatures, the correlation contribution to noise predominates over the contribution of individual particles. As a result, in the system of N electrons, the apparent charge (which is revealed via the shot noise) is changed from e at zero temperature to N e at high temperatures. It looks like the exchange correlations glue electrons into one particle of total charge and energy. This point of view is supported by both charge noise and heat noise. Interestingly, in the macroscopic limit, N →∞ , the correlation contribution completely suppresses the effect of temperature on noise.

  11. Does the body temperature change in older people?

    PubMed

    Güneş, Ulkü Yapucu; Zaybak, Ayten

    2008-09-01

    The aim of this study was to determine the mean body temperatures in older people using mercury-in-glass thermometer. Older people are unable to regulate their body temperatures to the same degree as young adults because their responses to changes in body temperature are altered. Several published reports suggest that body temperature decreases with advancing age and has a greater variability in older populations. The aim of this study was to determine the mean body temperatures in older people. Non-experimental. Axillary body temperatures were taken in 133 older subjects in a nursing home for older people using mercury-in-glass thermometer. Temperatures were measured at 8 a.m., 2 p.m., and 6 p.m., over three consecutive days. Each subject had all three measurements taken on the same day. The mean age of the subjects was 77.2, SD 7.3. In the 133 older subjects, the mean axillary temperatures ranged from 35.1 to 36.4 degrees C (95.3-97.6 degrees F). The mean temperatures for those aged 65-74 was higher than in those aged 75-84 (p < 0.001) and those aged 85 and older (p < 0.001) at 6 p.m. but not at 8 a.m. or 2 p.m. We concluded that older people have mean axillary body temperatures lower than the reference point of 36.5 degrees C (97.7 degrees F). When assessing body temperature, it is important to take the age of the patient into consideration. Also, the reference point of 36.5 degrees C is inappropriate in older people, especially when diagnosing a febrile illness.

  12. A new construction of measurement system based on specialized microsystem design for laryngological application

    NASA Astrophysics Data System (ADS)

    Paczesny, Daniel; Mikłaszewicz, Franciszek

    2013-10-01

    This article describes the design, construction and parameters of diagnostic medical system for air humidity measurement which can be proceeded in various places of human nasal cavities and also human throat. The system can measure dynamic changes of dew point temperature (absolute value of humidity) of inspired and expired air in different places of human upper airways. During regular respiration process dew point temperature is measured in nasal cavity, middle part cavity and nasopharynx. The presented system is the next step in construction of measurement system based on specialized microsystem for laryngological application. The microsystem fabricated on silicon substrate includes microheater, microthermoresistor and interdigitated electrodes. In comparison with previously built measurement system with current version some system functionalities and measurement parameters were improved. Additionally 3D printing technology was applied for rapid prototyping a measurement system housing. Presented measurement system is set of microprocessor module with signal conditioning circuits; heated measurement head based on specialized microsystem with disposable heated pipe for air sucking from various places of upper airways; power supplier and computer application for monitoring all system parameters and presenting on-line and off-line measured results. Some example results of constructed measurement system and dew point temperature measurements during respiration cycle are presented.

  13. Validation of UARS Microwave Limb Sounder Temperature and Pressure Measurements

    NASA Technical Reports Server (NTRS)

    Fishbein, E. F.; Cofield, R. E.; Froidevaux, L.; Jarnot, R. F.; Lungu, T.; Read, W. G.; Shippony, Z.; Waters, J. W.; McDermid, I. S.; McGee, T. J.; hide

    1996-01-01

    The accuracy and precision of the Upper Atmosphere Research Satellite (UARS) Microwave Limb Sounder (MLS) atmospheric temperature and tangent-point pressure measurements are described. Temperatures and tangent- point pressure (atmospheric pressure at the tangent height of the field of view boresight) are retrieved from a 15-channel 63-GHz radiometer measuring O2 microwave emissions from the stratosphere and mesosphere. The Version 3 data (first public release) contains scientifically useful temperatures from 22 to 0.46 hPa. Accuracy estimates are based on instrument performance, spectroscopic uncertainty and retrieval numerics, and range from 2.1 K at 22 hPa to 4.8 K at 0.46 hPa for temperature and from 200 m (equivalent log pressure) at 10 hPa to 300 m at 0.1 hPa. Temperature accuracy is limited mainly by uncertainty in instrument characterization, and tangent-point pressure accuracy is limited mainly by the accuracy of spectroscopic parameters. Precisions are around 1 K and 100 m. Comparisons are presented among temperatures from MLS, the National Meteorological Center (NMC) stratospheric analysis and lidar stations at Table Mountain, California, Observatory of Haute Provence (OHP), France, and Goddard Spaceflight Center, Maryland. MLS temperatures tend to be 1-2 K lower than NMC and lidar, but MLS is often 5 - 10 K lower than NMC in the winter at high latitudes, especially within the northern hemisphere vortex. Winter MLS and OHP (44 deg N) lidar temperatures generally agree and tend to be lower than NMC. Problems with Version 3 MLS temperatures and tangent-point pressures are identified, but the high precision of MLS radiances will allow improvements with better algorithms planned for the future.

  14. AVGAS/AUTOGAS (Aviation Gasoline/Automobile Gasoline) Comparison. Winter Grade Fuels.

    DTIC Science & Technology

    1986-07-01

    mass MAP Manifold pressure - inHg MON Motor Octane Number NIPER National Institute of Petroleum and Energy Resources Pamb Ambient pressure - inHg...pressure - psig si Sea level (used as a subscript) STC Supplemental Type Certificate Tamb Ambient temperature - degC or degF Tdew Dew point - degC or degF...temperature deg C #2 exhaust gas temperature deg C #3 exhaust gas temperature deg C #4 exhaust gas temperature deg C Ambient air temperature deg C 6

  15. Finite-temperature effects in helical quantum turbulence

    NASA Astrophysics Data System (ADS)

    Clark Di Leoni, Patricio; Mininni, Pablo D.; Brachet, Marc E.

    2018-04-01

    We perform a study of the evolution of helical quantum turbulence at different temperatures by solving numerically the Gross-Pitaevskii and the stochastic Ginzburg-Landau equations, using up to 40963 grid points with a pseudospectral method. We show that for temperatures close to the critical one, the fluid described by these equations can act as a classical viscous flow, with the decay of the incompressible kinetic energy and the helicity becoming exponential. The transition from this behavior to the one observed at zero temperature is smooth as a function of temperature. Moreover, the presence of strong thermal effects can inhibit the development of a proper turbulent cascade. We provide Ansätze for the effective viscosity and friction as a function of the temperature.

  16. Research about the high precision temperature measurement

    NASA Astrophysics Data System (ADS)

    Lin, J.; Yu, J.; Zhu, X.; Zeng, Z.; Deng, Y.

    2012-12-01

    High precision temperature control system is one of most important support conditions for tunable birefringent filter.As the first step,we researched some high precision temperature measurement methods for it. Firstly, circuits with a 24 bit ADC as the sensor's reader were carefully designed; Secondly, an ARM porcessor is used as the centrol processing unit, it provides sufficient reading and procesing ability; Thirdly, three kinds of sensors, PT100, Dale 01T1002-5 thermistor, Wheatstone bridge(constructed by pure copper and manganin) as the senor of the temperature were tested respectively. The resolution of the measurement with these three kinds of sensors are all better than 0.001 that's enough for 0.01 stability temperature control. Comparatively, Dale 01T1002-5 thermistor could get the most accurate temperature of the key point, Wheatstone bridge could get the most accurate mean temperature of the whole layer, both of them will be used in our futrue temperature controll system.

  17. Time-Temperature Profiling of United Kingdom Consumers' Domestic Refrigerators.

    PubMed

    Evans, Ellen W; Redmond, Elizabeth C

    2016-12-01

    Increased consumer demand for convenience and ready-to-eat food, along with changes to consumer food purchase and storage practices, have resulted in an increased reliance on refrigeration to maximize food safety. Previous research suggests that many domestic refrigerators operate at temperatures exceeding recommendations; however, the results of several studies were determined by means of one temperature data point, which, given temperature fluctuation, may not be a true indicator of actual continual operating temperatures. Data detailing actual operating temperatures and the effects of consumer practices on temperatures are limited. This study has collated the time-temperature profiles of domestic refrigerators in consumer kitchens (n = 43) over 6.5 days with concurrent self-reported refrigerator usage. Overall, the findings established a significant difference (P < 0.05) between one-off temperature (the recording of one temperature data point) and mean operating temperature. No refrigerator operated at ≤5.0°C for the entire duration of the study. Mean temperatures exceeding 5.0°C were recorded in the majority (91%) of refrigerators. No significant associations or differences were determined for temperature profiles and demographics, including household size, or refrigerator characteristics (age, type, loading, and location). A positive correlation (P < 0.05) between room temperature and refrigerator temperature was determined. Reported door opening frequency correlated with temperature fluctuation (P < 0.05). Thermometer usage was determined to be infrequent. Cumulatively, research findings have established that the majority of domestic refrigerators in consumer homes operate at potentially unsafe temperatures and that this is influenced by consumer usage. The findings from this study may be utilized to inform the development of shelf-life testing based on realistic domestic storage conditions. Furthermore, the data can inform the development of future

  18. Lifshitz transitions and zero point lattice fluctuations in sulfur hydride showing near room temperature superconductivity

    NASA Astrophysics Data System (ADS)

    Bianconi, Antonio; Jarlborg, Thomas

    2015-11-01

    Emerets's experiments on pressurized sulfur hydride have shown that H3S metal has the highest known superconducting critical temperature Tc = 203 K. The Emerets data show pressure induced changes of the isotope coefficient between 0.25 and 0.5, in disagreement with Eliashberg theory which predicts a nearly constant isotope coefficient.We assign the pressure dependent isotope coefficient to Lifshitz transitions induced by pressure and zero point lattice fluctuations. It is known that pressure could induce changes of the topology of the Fermi surface, called Lifshitz transitions, but were neglected in previous papers on the H3S superconductivity issue. Here we propose thatH3S is a multi-gap superconductor with a first condensate in the BCS regime (located in the large Fermi surface with high Fermi energy) which coexists with second condensates in the BCS-BEC crossover regime (located on the Fermi surface spots with small Fermi energy) near the and Mpoints.We discuss the Bianconi-Perali-Valletta (BPV) superconductivity theory to understand superconductivity in H3S since the BPV theory includes the corrections of the chemical potential due to pairing and the configuration interaction between different condensates, neglected by the Eliashberg theory. These two terms in the BPV theory give the shape resonance in superconducting gaps, similar to Feshbach resonance in ultracold fermionic gases, which is known to amplify the critical temperature. Therefore this work provides some key tools useful in the search for new room temperature superconductors.

  19. Comparison of the triple-point temperatures of {sup 20}Ne, {sup 22}Ne and normal Ne

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Nakano, T.; Tamura, O.; Nagao, K.

    2013-09-11

    At the National Metrology Institute of Japan (NMIJ), the triple points of {sup 20}Ne and {sup 22}Ne were realized using modular sealed cells, Ec3Ne20 and Ec8Ne22, made by the Istituto Nazionale di Ricerca Metrologica (INRiM) in Italy. The difference of the triple-point temperatures of {sup 20}Ne and {sup 22}Ne was estimated by using the sub-range of standard platinum resistance thermometers (SPRTs) calibrated by NMIJ on the International Temperature Scale of 1990 (ITS-90). The melting curves obtained with the Ec3Ne20 and Ec8Ne22 cells show narrow widths (0.1 mK) over a wide range of the inverse of the melted fraction (1/F) frommore » 1/F=1 to 1/F=10. The liquidus point T{sub tp} estimated by the melting curves from F∼0.5 to F∼0.85 using the Ec8Ne22 is 0.146 29 (4) K higher than that using the Ec3Ne20 cell, which is in good agreement with that observed by INRiM using the same cells. After correction of the effect of impurities and other isotopes for Ec3Ne20 and Ec8Ne22 cells, the difference of T{sub tp} between pure {sup 20}Ne and pure {sup 22}Ne is estimated to be 0.146 61 (4) K, which is consistent with the recent results reported elsewhere. The sub-ranges of SPRTs computed by using the triple point of {sup 20}Ne or {sup 22}Ne realized by the Ec3Ne20 cell or the Ec8Ne22 cell in place of the triple point of Ne for the defining fixed point of the ITS-90 are in good agreement with those realized on the basis of the ITS-90 at NMIJ within 0.03 mK, which is much smaller than the non-uniqueness and the sub-range inconsistency of SPRTs.« less

  20. Peak capacity, peak-capacity production rate, and boiling point resolution for temperature-programmed GC with very high programming rates

    PubMed

    Grall; Leonard; Sacks

    2000-02-01

    Recent advances in column heating technology have made possible very fast linear temperature programming for high-speed gas chromatography. A fused-silica capillary column is contained in a tubular metal jacket, which is resistively heated by a precision power supply. With very rapid column heating, the rate of peak-capacity production is significantly enhanced, but the total peak capacity and the boiling-point resolution (minimum boiling-point difference required for the separation of two nonpolar compounds on a nonpolar column) are reduced relative to more conventional heating rates used with convection-oven instruments. As temperature-programming rates increase, elution temperatures also increase with the result that retention may become insignificant prior to elution. This results in inefficient utilization of the down-stream end of the column and causes a loss in the rate of peak-capacity production. The rate of peak-capacity production is increased by the use of shorter columns and higher carrier gas velocities. With high programming rates (100-600 degrees C/min), column lengths of 6-12 m and average linear carrier gas velocities in the 100-150 cm/s range are satisfactory. In this study, the rate of peak-capacity production, the total peak capacity, and the boiling point resolution are determined for C10-C28 n-alkanes using 6-18 m long columns, 50-200 cm/s average carrier gas velocities, and 60-600 degrees C/min programming rates. It was found that with a 6-meter-long, 0.25-mm i.d. column programmed at a rate of 600 degrees C/min, a maximum peak-capacity production rate of 6.1 peaks/s was obtained. A total peak capacity of about 75 peaks was produced in a 37-s long separation spanning a boiling-point range from n-C10 (174 degrees C) to n-C28 (432 degrees C).

  1. Distribution of point defects in Si(100)/Si grown by low-temperature molecular-beam epitaxy and solid-phase epitaxy

    NASA Astrophysics Data System (ADS)

    Asoka-Kumar, P.; Gossmann, H.-J.; Unterwald, F. C.; Feldman, L. C.; Leung, T. C.; Au, H. L.; Talyanski, V.; Nielsen, B.; Lynn, K. G.

    1993-08-01

    Positron annihilation in Si is a quantitaive, depth-sensitive technique for the detection of vacancylike defects or voids. A sensitivity of 5×1015 cm-3 for voidlike defects is easily achieved. The technique has been applied to a study of point-defect distributions in thin films of Si grown by molecular-beam epitaxy. A special procedure was developed to remove the influence of the native oxide on the positron measurement. 200-nm-thick films grown at temperatures between 475 and 560 °C show no defects below the sensitivity limit and are indistinguishable from the bulk substrate. So are films grown at 220 °C, provided a 2-min high-temperature anneal to a peak temperature of >=500 °C is executed every ~=30 nm during growth. If TRTA=450 °C, part of the film contains vacancylike defects to a concentration of ~=1018 cm-3. These results correlate well with current-voltage characteristics of p-n junctions grown with different rapid thermal anneal (RTA) temperatures. Ion scattering, with a defect sensitivity of ~=1%, shows no difference between films grown with different TRTA. Recrystallization of amorphous films, deposited at room temperature and annealed in situ at 550 °C, always leaves a significant defect concentration of ~=2×1018 cm-3; those defects are reduced but still present even after a 2-h 800 °C furnace anneal.

  2. An efficient technique for determining apparent temperature distributions from antenna temperature measurements

    NASA Technical Reports Server (NTRS)

    Claassen, J. P.; Fung, A. K.

    1973-01-01

    A method by which the apparent microwave temperature characteristic of a flat scene is estimated from dual polarized measurements is derived and interpreted. Approximate linear relationships between antenna and apparent temperatures are established by weighting emission components in spherical bands under the assumption that the surface is isotropic. The weighting factors are formed by integrating the antenna pattern functions over these bands. The vector aspect of the formulation is retained to account for the difference between the definition of the antenna polarizations and the polarizations of the emitted fields. The method is largely applicable to the measurement of smooth temperature distributions by an antenna having good spatial resolution of the distributions and is considered efficient for inverting large volumes of measurements. Sample cases are presented and the implications of these cases on remote radiometer observations are discussed. It is shown that cross-coupling occurs between the polarizations of the emitted fields and the polarizations of the antenna. For this reason and because practical antennas have cross-polarized patterns associated with them, it is necessary to conduct measurements at both horizontal and vertical polarizations to realize the inversion. It is also made evident that thorough inversions require that the apparent temperatures be sampled at a sufficient number of points between nadir and zenith.

  3. Temperature compensation and temperature sensation in the circadian clock

    PubMed Central

    Kidd, Philip B.; Young, Michael W.; Siggia, Eric D.

    2015-01-01

    All known circadian clocks have an endogenous period that is remarkably insensitive to temperature, a property known as temperature compensation, while at the same time being readily entrained by a diurnal temperature oscillation. Although temperature compensation and entrainment are defining features of circadian clocks, their mechanisms remain poorly understood. Most models presume that multiple steps in the circadian cycle are temperature-dependent, thus facilitating temperature entrainment, but then insist that the effect of changes around the cycle sums to zero to enforce temperature compensation. An alternative theory proposes that the circadian oscillator evolved from an adaptive temperature sensor: a gene circuit that responds only to temperature changes. This theory implies that temperature changes should linearly rescale the amplitudes of clock component oscillations but leave phase relationships and shapes unchanged. We show using timeless luciferase reporter measurements and Western blots against TIMELESS protein that this prediction is satisfied by the Drosophila circadian clock. We also review evidence for pathways that couple temperature to the circadian clock, and show previously unidentified evidence for coupling between the Drosophila clock and the heat-shock pathway. PMID:26578788

  4. A spectral measurement method for determining white OLED average junction temperatures

    NASA Astrophysics Data System (ADS)

    Zhu, Yiting; Narendran, Nadarajah

    2016-09-01

    The objective of this study was to investigate an indirect method of measuring the average junction temperature of a white organic light-emitting diode (OLED) based on temperature sensitivity differences in the radiant power emitted by individual emitter materials (i.e., "blue," "green," and "red"). The measured spectral power distributions (SPDs) of the white OLED as a function of temperature showed amplitude decrease as a function of temperature in the different spectral bands, red, green, and blue. Analyzed data showed a good linear correlation between the integrated radiance for each spectral band and the OLED panel temperature, measured at a reference point on the back surface of the panel. The integrated radiance ratio of the spectral band green compared to red, (G/R), correlates linearly with panel temperature. Assuming that the panel reference point temperature is proportional to the average junction temperature of the OLED panel, the G/R ratio can be used for estimating the average junction temperature of an OLED panel.

  5. Temperature characteristics for PTC material heating diesel fuel

    NASA Astrophysics Data System (ADS)

    Gu, Lefeng; Li, Xiaolu; Wang, Jun; Li, Ying; Li, Ming

    2010-08-01

    This paper gives a way which utilizes the PTC (Positive Temperature Coefficient) material to preheat diesel fuel in the injector in order to improve the cold starting and emissions of engine. A new injector is also designed. In order to understand the preheating process in this new injector, a dynamic temperature testing system combined with the MSP430F149 data acquisition system is developed for PTC material heating diesel fuel. Especially, the corresponding software and hardware circuits are explained. The temperature of diesel fuel preheating by PTC ceramics is measured under different voltages and distances, which Curie point is 75 °C. Diesel fuel is heated by self-defined temperature around the Curie point of PTC ceramics. The diesel fuel temperature rises rapidly in 2 minutes of the beginning, then can reach 60 °C within 5 minutes as its distance is 5mm away from the surface of PTC ceramics. However, there are a lot of fundamental studies and technology to be resolved in order to apply PTC material in the injector successfully.

  6. Accumulation of ammonia and other potentially noxious gases on live export shipments from Australia to the Middle East.

    PubMed

    Pines, M K; Phillips, C J C

    2011-10-01

    Noxious gases on ships are irritant pollutants that have potential impacts on the comfort and health of both livestock and humans. Identification of environmental influences on the pollutants will assist live exporters to control them. Ammonia, hydrogen sulphide and carbon dioxide, as well as wet and dry bulb temperature, dew point, air speed and depth of faeces that the sheep stood in, were measured on two ship voyages in which sheep were transported from Australia to the Middle East. Daily measurements were made at 20 measurement locations over 12 days. At four sites, the mean ammonia concentration for the voyage was above the recommended maximum limit for the live export industry (25 ppm). The mean ammonia concentrations at the remaining 16 sites were below 18 ppm and considered safe. High ammonia concentrations were localised and occurred particularly on closed decks, as well as at the front of the vessel and near the engine block on open decks. Ammonia concentration on the open decks was correlated with cumulative wind during the voyage, air speed, dew point, wet bulb temperature and faecal pad depth, and on the closed decks with dew point, and wet and dry bulb temperature. Hydrogen sulphide (<1.8 ppm) and carbon dioxide (<1900 ppm) concentrations were low and did not pose a risk to animal or human welfare or health. The results suggest that high ammonia concentrations occur in those parts of the ship where there is insufficient ventilation and/or high temperatures and humidity.

  7. Evaluation of Rock Surface Characterization by Means of Temperature Distribution

    NASA Astrophysics Data System (ADS)

    Seker, D. Z.; Incekara, A. H.; Acar, A.; Kaya, S.; Bayram, B.; Sivri, N.

    2017-12-01

    Rocks have many different types which are formed over many years. Close range photogrammetry is a techniques widely used and preferred rather than other conventional methods. In this method, the photographs overlapping each other are the basic data source of the point cloud data which is the main data source for 3D model that provides analysts automation possibility. Due to irregular and complex structures of rocks, representation of their surfaces with a large number points is more effective. Color differences caused by weathering on the rock surfaces or naturally occurring make it possible to produce enough number of point clouds from the photographs. Objects such as small trees, shrubs and weeds on and around the surface also contribute to this. These differences and properties are important for efficient operation of pixel matching algorithms to generate adequate point cloud from photographs. In this study, possibilities of using temperature distribution for interpretation of roughness of rock surface which is one of the parameters representing the surface, was investigated. For the study, a small rock which is in size of 3 m x 1 m, located at ITU Ayazaga Campus was selected as study object. Two different methods were used. The first one is production of producing choropleth map by interpolation using temperature values of control points marked on object which were also used in 3D model. 3D object model was created with the help of terrestrial photographs and 12 control points marked on the object and coordinated. Temperature value of control points were measured by using infrared thermometer and used as basic data source in order to create choropleth map with interpolation. Temperature values range from 32 to 37.2 degrees. In the second method, 3D object model was produced by means of terrestrial thermal photographs. Fort this purpose, several terrestrial photographs were taken by thermal camera and 3D object model showing temperature distribution was created

  8. The NBS scale of radiance temperature

    NASA Technical Reports Server (NTRS)

    Waters, William R.; Walker, James H.; Hattenburg, Albert T.

    1988-01-01

    The measurement methods and instrumentation used in the realization and transfer of the International Practical Temperature Scale (IPTS-68) above the temperature of freezing gold are described. The determination of the ratios of spectral radiance of tungsten-strip lamps to a gold-point blackbody at a wavelength of 654.6 nm is detailed. The response linearity, spectral responsivity, scattering error, and polarization properties of the instrumentation are described. The analysis of the sources of error and estimates of uncertainty are presented. The assigned uncertainties (three standard deviations) in radiance temperature range from + or - 2 K at 2573 K to + or - 0.5 K at 1073 K.

  9. Improved Low Temperature Performance of Supercapacitors

    NASA Technical Reports Server (NTRS)

    Brandon, Erik J.; West, William C.; Smart, Marshall C.; Gnanaraj, Joe

    2013-01-01

    Low temperature double-layer capacitor operation enabled by: - Base acetonitrile / TEATFB salt formulation - Addition of low melting point formates, esters and cyclic ethers center dot Key electrolyte design factors: - Volume of co-solvent - Concentration of salt center dot Capacity increased through higher capacity electrodes: - Zeolite templated carbons - Asymmetric cell designs center dot Continuing efforts - Improve asymmetric cell performance at low temperature - Cycle life testing Motivation center dot Benchmark performance of commercial cells center dot Approaches for designing low temperature systems - Symmetric cells (activated carbon electrodes) - Symmetric cells (zeolite templated carbon electrodes) - Asymmetric cells (lithium titanate/activated carbon electrodes) center dot Experimental results center dot Summary

  10. Development and Performance Verification of Fiber Optic Temperature Sensors in High Temperature Engine Environments

    NASA Technical Reports Server (NTRS)

    Adamovsky, Grigory; Mackey, Jeffrey R.; Kren, Lawrence A.; Floyd, Bertram M.; Elam, Kristie A.; Martinez, Martel

    2014-01-01

    A High Temperature Fiber Optic Sensor (HTFOS) has been developed at NASA Glenn Research Center for aircraft engine applications. After fabrication and preliminary in-house performance evaluation, the HTFOS was tested in an engine environment at NASA Armstrong Flight Research Center. The engine tests enabled the performance of the HTFOS in real engine environments to be evaluated along with the ability of the sensor to respond to changes in the engine's operating condition. Data were collected prior, during, and after each test in order to observe the change in temperature from ambient to each of the various test point levels. An adequate amount of data was collected and analyzed to satisfy the research team that HTFOS operates properly while the engine was running. Temperature measurements made by HTFOS while the engine was running agreed with those anticipated.

  11. Ab initio calculation of finite-temperature charmonium potentials

    NASA Astrophysics Data System (ADS)

    Evans, P. W. M.; Allton, C. R.; Skullerud, J.-I.

    2014-04-01

    The interquark potential in charmonium states is calculated in both the zero and nonzero temperature phases from a first-principles lattice QCD calculation. Simulations with two dynamical quark flavors are used with temperatures T in the range 0.4Tc≲T≲1.7Tc, where Tc is the deconfining temperature. The correlators of point-split operators are analyzed to gain spatial information about the charmonium states. A method introduced by the HAL QCD Collaboration and based on the Schrödinger equation is applied to obtain the interquark potential. We find a clear temperature dependence with the central potential agreeing with the Cornell potential in the confined phase and becoming flatter (more screened) as the temperature increases past the deconfining temperature. This is the first time the interquark potential has been calculated for realistic quarks at finite temperature.

  12. Effects of cold and hot temperature on dehydration: a mechanism of cardiovascular burden.

    PubMed

    Lim, Youn-Hee; Park, Min-Seon; Kim, Yoonhee; Kim, Ho; Hong, Yun-Chul

    2015-08-01

    The association between temperature (cold or heat) and cardiovascular mortality has been well documented. However, few studies have investigated the underlying mechanism of the cold or heat effect. The main goal of this study was to examine the effect of temperature on dehydration markers and to explain the pathophysiological disturbances caused by changes of temperature. We investigated the relationship between outdoor temperature and dehydration markers (blood urea nitrogen (BUN)/creatinine ratio, urine specific gravity, plasma tonicity and haematocrit) in 43,549 adults from Seoul, South Korea, during 1995-2008. We used piece-wise linear regression to find the flexion point of apparent temperature and estimate the effects below or above the apparent temperature. Levels of dehydration markers decreased linearly with an increase in the apparent temperature until a point between 22 and 27 °C, which was regarded as the flexion point of apparent temperature, and then increased with apparent temperature. Because the associations between temperature and cardiovascular mortality are known to be U-shaped, our findings suggest that temperature-related changes in hydration status underlie the increased cardiovascular mortality and morbidity during high- or low-temperature conditions.

  13. Advances in thermal control and performance of the MMT M1 mirror

    NASA Astrophysics Data System (ADS)

    Gibson, J. D.; Williams, G. G.; Callahan, S.; Comisso, B.; Ortiz, R.; Williams, J. T.

    2010-07-01

    Strategies for thermal control of the 6.5-meter diameter borosilicate honeycomb primary (M1) mirror at the MMT Observatory have included: 1) direct control of ventilation system chiller setpoints by the telescope operator, 2) semiautomated control of chiller setpoints, using a fixed offset from the ambient temperature, and 3) most recently, an automated temperature controller for conditioned air. Details of this automated controller, including the integration of multiple chillers, heat exchangers, and temperature/dew point sensors, are presented here. Constraints and sanity checks for thermal control are also discussed, including: 1) mirror and hardware safety, 2) aluminum coating preservation, and 3) optimization of M1 thermal conditions for science acquisition by minimizing both air-to-glass temperature differences, which cause mirror seeing, and internal glass temperature gradients, which cause wavefront errors. Consideration is given to special operating conditions, such as high dew and frost points. Precise temperature control of conditioned ventilation air as delivered to the M1 mirror cell is also discussed. The performance of the new automated controller is assessed and compared to previous control strategies. Finally, suggestions are made for further refinement of the M1 mirror thermal control system and related algorithms.

  14. Measuring Relative Humidity.

    ERIC Educational Resources Information Center

    Pinkham, Chester A.; Barrett, Kristin Burrows

    1992-01-01

    Describes four experiments that enable students to explore the phenomena of evaporation and condensation and determine the relative humidity by measuring air temperature and dew point on warm September days. Provides tables to calculate saturation points and relative humidity. (MDH)

  15. A short note on the inclusion of sultriness issues in perceived temperature in mild climates

    NASA Astrophysics Data System (ADS)

    Staiger, Henning; Laschewski, Gudrun; Matzarakis, Andreas

    2018-01-01

    Sultriness is a specific case in thermal perception under warm/humid environments and frequently applied in German operational weather forecast and is assumed if the dew-point temperature t d exceeds a threshold of 16.5 °C. In perceived temperature ( PT), which is based on the ASHRAE two-node-model, a Central European climatology was prepared of the classical predicted mean vote ( PMV), exclusively linked to thermal stress, and the so-called rational PMV* that additionally accounts for the humidity in the meteorological environment and is closely linked to thermal strain. The standard deviation of the difference Δ PMV = PMV* - PMV over PMV reveals a similarity to the appearance of sultriness that suggests as side effect of the PT parameterisation a thermophysiologically based definition of sultriness: "Under warm/humid conditions a subject adapted to mild climatologic conditions perceives sultriness if the actual value of Δ PMV exceeds the long-term mean by more than its single standard deviation". This definition accounts for all environmental and subject related variables influencing the thermal state of the body and is in accordance with all in the literature described properties in the perception of sultriness. The two definitions coincide more or less at daylight hours for t d values markedly beyond the threshold. However, in the t d threshold region, the PT-derived definition offers stronger differentiated patterns and is significantly less frequent at nighttime than the mono-causal definition. For given PT values, the sensible heat flux via the skin shows an increase under a sultry environment, whereas the latent is reduced; skin and core temperatures as well as the skin blood flow are also less. In any case, PT-derived sultriness is linked with an increased thermal strain on the body temperatures, which is a measure of discomfort caused by increased humidity and/or dissatisfaction with the thermal environment. This confirms the thermal uncomfortable

  16. Localized temperature stability of low temperature cofired ceramics

    DOEpatents

    Dai, Steven Xunhu

    2013-11-26

    The present invention is directed to low temperature cofired ceramic modules having localized temperature stability by incorporating temperature coefficient of resonant frequency compensating materials locally into a multilayer LTCC module. Chemical interactions can be minimized and physical compatibility between the compensating materials and the host LTCC dielectrics can be achieved. The invention enables embedded resonators with nearly temperature-independent resonance frequency.

  17. Synergistic effect of temperature and point defect on the mechanical properties of single layer and bi-layer graphene

    NASA Astrophysics Data System (ADS)

    Debroy, Sanghamitra; Pavan Kumar, V.; Vijaya Sekhar, K.; Acharyya, Swati Ghosh; Acharyya, Amit

    2017-10-01

    The present study reports a comprehensive molecular dynamics simulation of the effect of a) temperature (300-1073 K at intervals of every 100 K) and b) point defect on the mechanical behaviour of single (armchair and zigzag direction) and bilayer layer graphene (AA and AB stacking). Adaptive intermolecular reactive bond order (AIREBO) potential function was used to describe the many-body short-range interatomic interactions for the single layer graphene sheet. Moreover, Lennard Jones model was considered for bilayer graphene to incorporate the van der Waals interactions among the interlayers of graphene. The effect of temperature on the strain energy of single layer and bilayer graphene was studied in order to understand the difference in mechanical behaviour of the two systems. The strength of the pristine single layer graphene was found to be higher as compared to bilayer AA stacked graphene at all temperatures. It was observed at 1073 K and in the presence of vacancy defect the strength for single layer armchair sheet falls by 30% and for bilayer armchair sheet by 33% as compared to the pristine sheets at 300 K. The AB stacked graphene sheet was found to have a two-step rupture process. The strength of pristine AB sheet was found to decrease by 22% on increase of temperature from 300 K to 1073 K.

  18. Design, fabrication and testing of an optical temperature sensor

    NASA Technical Reports Server (NTRS)

    Morey, W. W.; Glenn, W. H.; Decker, R. O.; Mcclurg, W. C.

    1980-01-01

    The laboratory breadboard optical temperature sensor based on the temperature dependent absorptive characteristics of a rare earth (europium) doped optical fiber. The principles of operation, materials characterization, fiber and optical component design, design and fabrication of an electrooptic interface unit, signal processing, and initial test results are discussed. Initial tests indicated that, after a brief warmup period, the output of the sensor was stable to approximately 1 C at room temperature or approximately + or - 0.3 percent of point (K). This exceeds the goal of 1 percent of point. Recommendations are presented for further performance improvement.

  19. Measuring Humidity in Sealed Glass Encasements

    NASA Technical Reports Server (NTRS)

    West, James W.; Burkett, Cecil G.; Levine, Joel S.

    2005-01-01

    A technique has been devised for measuring the relative humidity levels in the protective helium/water vapor atmosphere in which the Declaration of Independence, the United States Constitution, and the Bill of Rights are encased behind glass panels on display at the National Archives in Washington, DC. The technique is noninvasive: it does not involve penetrating the encasements (thereby risking contamination or damage to the priceless documents) to acquire samples of the atmosphere. The technique could also be applied to similar glass encasements used to protect and display important documents and other precious objects in museums. The basic principle of the technique is straightforward: An encasement is maintained at its normal display or operating temperature (e.g., room temperature) while a portion of its glass front panel is chilled (see Figure 1) until condensed water droplets become visible on the inside of the panel. The relative humidity of the enclosed atmosphere can then be determined as a known function of the dew point, the temperature below which the droplets condense. Notwithstanding the straightforwardness of the basic principle, careful attention to detail is necessary to enable accurate determination of the dew point. In the initial application, the affected portion of the glass panel was cooled by contact with an aluminum plate that was cooled by a thermoelectric module, the exhaust heat of which was dissipated by a heat sink cooled by a fan. A thermocouple was used to measure the interior temperature of the aluminum plate, and six other thermocouples were used to measure the temperatures at six locations on the cooled outer surface of the glass panel (see Figure 2). Thermal grease was applied to the aluminum plate and the thermocouples to ensure close thermal contact. Power was supplied to the thermoelectric module in small increments, based on previous laboratory tests. A small flashlight and a magnifying glass were used to look for water

  20. Temperature and heat flux measurements: Challenges for high temperature aerospace application

    NASA Technical Reports Server (NTRS)

    Neumann, Richard D.

    1992-01-01

    The measurement of high temperatures and the influence of heat transfer data is not strictly a problem of either the high temperatures involved or the level of the heating rates to be measured at those high temperatures. It is a problem of duration during which measurements are made and the nature of the materials in which the measurements are made. Thermal measurement techniques for each application must respect and work with the unique features of that application. Six challenges in the development of measurement technology are discussed: (1) to capture the character and localized peak values within highly nonuniform heating regions; (2) to manage large volumes of thermal instrumentation in order to efficiently derive critical information; (3) to accommodate thermal sensors into practical flight structures; (4) to broaden the capabilities of thermal survey techniques to replace discrete gages in flight and on the ground; (5) to provide supporting instrumentation conduits which connect the measurement points to the thermally controlled data acquisition system; and (6) to develop a class of 'vehicle tending' thermal sensors to assure the integrity of flight vehicles in an efficient manner.

  1. Temperature Control System for Mushroom Dryer

    NASA Astrophysics Data System (ADS)

    Wibowo, I. A.; Indah, Nur; Sebayang, D.; Adam, N. H.

    2018-03-01

    The main problem in mushroom cultivation is the handling after the harvest. Drying is one technique to preserve the mushrooms. Traditionally, mushrooms are dried by sunshine which depends on the weather. This affects the quality of the dried mushrooms. Therefore, this paper proposes a system to provide an artificial drying for mushrooms in order to maintain their quality. The objective of the system is to control the mushroom drying process to be faster compared to the natural drying at an accurate and right temperature. A model of the mushroom dryer has been designed, built, and tested. The system comprises a chamber, heater, blower, temperature sensor and electronic control circuit. A microcontroller is used as the controller which is programmed to implement a bang-bang control that regulates the temperature of the chamber. A desired temperature is inputted as a set point of the control system. Temperature of 45 °C is chosen as the operational drying temperature. Several tests have been carried out to examine the performance of the system including drying speed, the effects of ambient conditions, and the effects of mushroom size. The results show that the system can satisfy the objective.

  2. Computer modeling of the sensitivity of a laser water vapor sensor to variations in temperature and air speed

    NASA Technical Reports Server (NTRS)

    Tucker, George F.

    1994-01-01

    Currently, there is disagreement among existing methods of determining atmospheric water vapor concentration at dew-points below -40 C. A major source of error is wall effects which result from the necessity of bringing samples into the instruments. All of these instruments also have response times on the order of seconds. NASA Langley is developing a water vapor sensor which utilizes the absorption of the infrared radiation produced by a diode laser to estimate water vapor concentration. The laser beam is directed through an aircraft window to a retroreflector located on an engine. The reflected beam is detected by an infrared detector located near the laser. To maximize signal to noise, derivative signals are analyzed. By measuring the 2f/DC signal and correcting for ambient temperature, atmospheric pressure and air speed (which results in a Doppler shifting of the laser beam), the water vapor concentration can be retrieved. Since this is an in situ measurement there are no wall effects and measurements can be made at a rate of more than 20 per second. This allows small spatial variations of water vapor to be studied. In order to study the sensitivity of the instrument to variations in temperature and air speed, a computer program which generated the 2f, 3f, 4f, DC and 2f/DC signals of the instrument as a function of temperature, pressure and air speed was written. This model was used to determine the effect of errors in measurement of the temperature and air speed on the measured water vapor concentration. Future studies will quantify the effect of pressure measurement errors, which are expected to be very small. As a result of these studied, a retrieval algorithm has been formulated, and will be applied to data taken during the PEM-West atmospheric science field mission. Spectroscopic studies of the water vapor line used by the instrument will be used to refine this algorithm. To prepare for these studies, several lasers have been studied to determine their

  3. pKa of fentanyl varies with temperature: implications for acid-base management during extremes of body temperature.

    PubMed

    Thurlkill, Richard L; Cross, David A; Scholtz, J Martin; Pace, C Nick

    2005-12-01

    The pKa of fentanyl has not been measured previously at varying extremes of body temperature. The goal of this laboratory investigation was to test the hypothesis that the pKa of fentanyl changes with temperature. The investigation involved measuring the pKa values of aqueous fentanyl at varying temperatures. The investigation was conducted in a controlled laboratory environment. No human or animal subjects were involved. Because no live subjects were involved in the investigation, no interventions were necessary. This paper reports the effect of temperature on the pKa of fentanyl. The pKa of aqueous fentanyl was measured at 15 degrees C, 25 degrees C, 37 degrees C, 42 degrees C, and 47.5 degrees C by potentiometric titration in 0.01 mmol/L of potassium chloride after extensive degassing. Data were analyzed using the least squares method with an appropriately fitting equation. The pKa of fentanyl was found to change in a similar manner to the neutral point of water at varying temperatures. This finding has implications for the bioavailability of fentanyl at extremes of body temperature in association with the clinical acid-base management of the patient. Clinical implications for differing methods of intraoperative acid-base management at varying temperatures are discussed.

  4. Methods of Controlling the Loop Heat Pipe Operating Temperature

    NASA Technical Reports Server (NTRS)

    Ku, Jentung

    2008-01-01

    The operating temperature of a loop heat pipe (LHP) is governed by the saturation temperature of its compensation chamber (CC); the latter is in turn determined by the balance among the heat leak from the evaporator to the CC, the amount of subcooling carried by the liquid returning to the CC, and the amount of heat exchanged between the CC and ambient. The LHP operating temperature can be controlled at a desired set point by actively controlling the CC temperature. The most common method is to cold bias the CC and use electric heater power to maintain the CC set point temperature. The required electric heater power can be large when the condenser sink is very cold. Several methods have been developed to reduce the control heater power, including coupling block, heat exchanger and separate subcooler, variable conductance heat pipe, by-pass valve with pressure regulator, secondary evaporator, and thermoelectric converter. The paper discusses the operating principles, advantages and disadvantages of each method.

  5. Dielectric determination of the glass transition temperature (T sub g)

    NASA Technical Reports Server (NTRS)

    Ries, Heidi R.

    1990-01-01

    The objective is to determine the glass transition temperature of a polymer using a dielectric dissipation technique. A peak in the dissipation factor versus temperature curve is expected near the glass transition temperature T sub g. It should be noted that the glass transition is gradual rather than abrupt, so that the glass transition temperature T sub g is not clearly identifiable. In this case, the glass transition temperature is defined to be the temperature at the intersection point of the tangent lines to the dissipation factor versus temperature curve above and below the transition region, as illustrated.

  6. Frequency of urban building fires as related to daily weather conditions

    Treesearch

    Arthur R. Pirsko; Wallace L. Fons

    1956-01-01

    Daily weather elements of precipitation, wind, mean temperature, relative humidity, and dew-point temperature for selected urban areas (approximately 850,000 population) in the United States are statistically analyzed to determine their correlation with daily number of building fires. The frequency of urban building fires is found to be significantly correlated with...

  7. 40 CFR 90.327 - Sampling system requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...

  8. 40 CFR 90.327 - Sampling system requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...

  9. 40 CFR 91.327 - Sampling system requirements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...

  10. 40 CFR 90.327 - Sampling system requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... each component (pump, sample line section, filters, and so forth) in the heated portion of the sampling... largest thermal mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may...

  11. 40 CFR 91.327 - Sampling system requirements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...

  12. 40 CFR 91.327 - Sampling system requirements.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ..., sample line section, filters, and so forth) in the heated portion of the sampling system that has a... mass and the oven temperature need be measured. (b) If water is removed by condensation, monitor the sample gas temperature or sample dew point either within the water trap or downstream. It may not exceed...

  13. Phase diagram for a two-dimensional, two-temperature, diffusive XY model.

    PubMed

    Reichl, Matthew D; Del Genio, Charo I; Bassler, Kevin E

    2010-10-01

    Using Monte Carlo simulations, we determine the phase diagram of a diffusive two-temperature conserved order parameter XY model. When the two temperatures are equal the system becomes the equilibrium XY model with the continuous Kosterlitz-Thouless (KT) vortex-antivortex unbinding phase transition. When the two temperatures are unequal the system is driven by an energy flow from the higher temperature heat-bath to the lower temperature one and reaches a far-from-equilibrium steady state. We show that the nonequilibrium phase diagram contains three phases: A homogenous disordered phase and two phases with long range, spin texture order. Two critical lines, representing continuous phase transitions from a homogenous disordered phase to two phases of long range order, meet at the equilibrium KT point. The shape of the nonequilibrium critical lines as they approach the KT point is described by a crossover exponent φ=2.52±0.05. Finally, we suggest that the transition between the two phases with long-range order is first-order, making the KT-point where all three phases meet a bicritical point.

  14. Phenol-Formaldehyde Resin for Optical-Chemical Temperature Sensing.

    PubMed

    Claucherty, Steven; Sakaue, Hirotaka

    2018-05-30

    The application of phenol-formaldehyde (PF) resin as an optical temperature sensor is investigated. Recent developments in optical luminescent sensors allow for global measurements to be made over the surface of a test article, extending beyond conventional point measurements. Global temperature distributions are particularly helpful when validating computational models or when mapping temperature over complex geometries, and can be used to calculate surface heat flux values. Temperature-sensitive paint (TSP) is a novel chemical approach to obtaining these global temperature measurements, but there are still challenges to overcome to make it a reliable tool. A sensor with a wide range of temperature sensitivity is desired to provide the maximum amount of utility, especially for tests spanning large temperature gradients. Naturally luminescent materials such as PF resin provide an attractive alternative to chemical sensor coatings, and PF resin is studied for this reason. Static tests of different PF resin samples are conducted using two binder materials to strengthen the material: cloth and paper. The material shows temperature sensitivities up to -0.8%/K, demonstrating the usefulness of PF resin as a temperature sensor.

  15. High temperature two component explosive

    DOEpatents

    Mars, James E.; Poole, Donald R.; Schmidt, Eckart W.; Wang, Charles

    1981-01-01

    A two component, high temperature, thermally stable explosive composition comprises a liquid or low melting oxidizer and a liquid or low melting organic fuel. The oxidizer and fuel in admixture are incapable of substantial spontaneous exothermic reaction at temperatures on the order of 475.degree. K. At temperatures on the order of 475.degree. K., the oxidizer and fuel in admixture have an activation energy of at least about 40 kcal/mol. As a result of the high activation energy, the preferred explosive compositions are nondetonable as solids at ambient temperature, and become detonable only when heated beyond the melting point. Preferable oxidizers are selected from alkali or alkaline earth metal nitrates, nitrites, perchlorates, and/or mixtures thereof. Preferred fuels are organic compounds having polar hydrophilic groups. The most preferred fuels are guanidinium nitrate, acetamide and mixtures of the two. Most preferred oxidizers are eutectic mixtures of lithium nitrate, potassium nitrate and sodium nitrate, of sodium nitrite, sodium nitrate and potassium nitrate, and of potassium nitrate, calcium nitrate and sodium nitrate.

  16. Mantle eclogites and garnet pyroxenites - the meaning of two-point isochrons, Sm-Nd and Lu-Hf closure temperatures and the cooling of the subcratonic mantle

    NASA Astrophysics Data System (ADS)

    Shu, Qiao; Brey, Gerhard P.; Gerdes, Axel; Hoefer, Heidi E.

    2014-03-01

    The Earth's mantle is a huge metamorphic complex which undergoes permanent changes ruled by plate tectonics. It also has enclaves underneath Archean crust which are exempt from the convecting mantle since at least 2.5 Ga. Since then, this mantle may cool slowly as a result of diminishing heat input from the asthenosphere, of declining heat production from radioactive decay and of denudation of the crust. Under such circumstances, two point garnet-clinopyroxene isochrons from mantle xenoliths (here garnet pyroxenites and eclogites) reflect either cooling ages or eruption ages depending on whether the mantle portion under consideration was below or above the closure temperature of a radiogenic system. Available literature data from the Slave and Kaapvaal craton for the Sm-Nd and Lu-Hf isotope systems and our own new data from Bellsbank (Kaapvaal) provide a whole range of two-point isochron ages from younger than the kimberlite eruption age to early Proterozoic. The meaning of ages other than the kimberlite eruption age is unclear. We use here a compilation of Sm-Nd and Lu-Hf two-point isochron age data from this study and the literature, to assess the meaning of such isochrons. This is achieved by plotting the temperature of last equilibration as derived from the Fe-Mg exchange between garnet and clinopyroxene versus the two-point isochron age. There is a low temperature alignment for both systems of increasing age with decreasing temperature and an alignment around the kimberlite eruption ages at high temperatures. We interpret the intersect between the low temperature limb and the kimberlite eruption age as closure temperature which gives about 920 °C for the Lu-Hf system and about 850 °C for the Sm-Nd system. The differences of the cooling ages between the two isotope systems for individual samples combined with the closure temperatures from this study are used to deduce the cooling of the Slave and Kaapvaal subcratonic mantle from the early Proterozoic until

  17. Active Temperature Compensation Using a High-Temperature, Fiber Optic, Hybrid Pressure and Temperature Sensor

    NASA Astrophysics Data System (ADS)

    Fielder, Robert S.; Palmer, Matthew E.; Davis, Matthew A.; Engelbrecht, Gordon P.

    2006-01-01

    Luna Innovations has developed a novel, fiber optic, hybrid pressure-temperature sensor system for extremely high-temperature environments that is capable of reliable operation up to 1050 °C. This system is based on the extremely high-temperature fiber optic sensors already demonstrated during previous work. The novelty of the sensors presented here lies in the fact that pressure and temperature are measured simultaneously with a single fiber and a single transducer. This hybrid approach will enable highly accurate active temperature compensation and sensor self-diagnostics not possible with other platforms. Hybrid pressure and temperature sensors were calibrated by varying both pressure and temperature. Implementing active temperature compensation resulted in a ten-fold reduction in the temperature-dependence of the pressure measurement. Sensors were tested for operability in a relatively high neutron dose environment up to 6.9×1017 n/cm2. In addition to harsh environment survivability, fiber optic sensors offer a number of intrinsic advantages for space nuclear power applications including extremely low mass, immunity to electromagnetic interference, self diagnostics / prognostics, and smart sensor capability. Deploying fiber optic sensors on future space exploration missions would provide a substantial improvement in spacecraft instrumentation. Additional development is needed, however, before these advantages can be realized. This paper will highlight recent demonstrations of fiber optic sensors in environments relevant to space nuclear applications. Successes and lessons learned will be highlighted. Additionally, development needs will be covered which will suggest a framework for a coherent plan to continue work in this area.

  18. Outdoor surface temperature measurement: ground truth or lie?

    NASA Astrophysics Data System (ADS)

    Skauli, Torbjorn

    2004-08-01

    Contact surface temperature measurement in the field is essential in trials of thermal imaging systems and camouflage, as well as for scene modeling studies. The accuracy of such measurements is challenged by environmental factors such as sun and wind, which induce temperature gradients around a surface sensor and lead to incorrect temperature readings. In this work, a simple method is used to test temperature sensors under conditions representative of a surface whose temperature is determined by heat exchange with the environment. The tested sensors are different types of thermocouples and platinum thermistors typically used in field trials, as well as digital temperature sensors. The results illustrate that the actual measurement errors can be much larger than the specified accuracy of the sensors. The measurement error typically scales with the difference between surface temperature and ambient air temperature. Unless proper care is taken, systematic errors can easily reach 10% of this temperature difference, which is often unacceptable. Reasonably accurate readings are obtained using a miniature platinum thermistor. Thermocouples can perform well on bare metal surfaces if the connection to the surface is highly conductive. It is pointed out that digital temperature sensors have many advantages for field trials use.

  19. Velocity and temperature profiles in near-critical nitrogen flowing past a horizontal flat plate

    NASA Technical Reports Server (NTRS)

    Simoneau, R. J.

    1977-01-01

    Boundary layer velocity and temperature profiles were measured for nitrogen near its thermodynamic critical point flowing past a horizontal flat plate. The results were compared measurements made for vertically upward flow. The boundary layer temperatures ranged from below to above the thermodynamic critical temperature. For wall temperatures below the thermodynamic critical temperature there was little variation between the velocity and temperature profiles in three orientations. In all three orientations the point of crossing into the critical temperature region is marked by a significant flattening of the velocity and temperature profiles and also a decrease in heat transfer coefficient.

  20. Research on early-warning index of the spatial temperature field in concrete dams.

    PubMed

    Yang, Guang; Gu, Chongshi; Bao, Tengfei; Cui, Zhenming; Kan, Kan

    2016-01-01

    Warning indicators of the dam body's temperature are required for the real-time monitoring of the service conditions of concrete dams to ensure safety and normal operations. Warnings theories are traditionally targeted at a single point which have limitations, and the scientific warning theories on global behavior of the temperature field are non-existent. In this paper, first, in 3D space, the behavior of temperature field has regional dissimilarity. Through the Ward spatial clustering method, the temperature field was divided into regions. Second, the degree of order and degree of disorder of the temperature monitoring points were defined by the probability method. Third, the weight values of monitoring points of each regions were explored via projection pursuit. Forth, a temperature entropy expression that can describe degree of order of the spatial temperature field in concrete dams was established. Fifth, the early-warning index of temperature entropy was set up according to the calculated sequential value of temperature entropy. Finally, project cases verified the feasibility of the proposed theories. The early-warning index of temperature entropy is conducive to the improvement of early-warning ability and safety management levels during the operation of high concrete dams.

  1. Recovery of Waste Heat from Propellant Forced-Air Dry House

    DTIC Science & Technology

    1978-12-01

    function of bulk air side film heat transfer coefficient and diffusivity 66 15. Dry house waste heat recovery system instrumentation 67 16. Sample data...inlet condition by, maintaining the exhaust temperature above the NG dew point. The set point is adjustable to accommodate various propel- lant and...system. In dry cycle operation, an overall energy recovery effectiveness of about 40% was measured for winter operation when the exhaust temperature

  2. Characterization of canopy dew formation in tropical forests using active microwave remote sensing

    NASA Astrophysics Data System (ADS)

    Gerlein-Safdi, C.; Frolking, S. E.; Caylor, K. K.

    2016-12-01

    Dew deposition in a closed canopy is thought to be greatest on top of the canopy, since a clear view of the sky increases condensation. In tropical forests, these same leaves are also subject to direct sunlight and high transpiration rates. Dew deposition can offset some of the water stress through foliar uptake of the dew droplets, or transpiration suppression from the energy dissipation associated with dew evaporation. However, the long-term trends of dew formation and their global patterns have received little attention, despite the wide acknowledgement that non-meteoric water can be a key source of water for many species, especially in tropical ecosystems. As such, accumulated and future effects of climate change on non-meteoric water occurrence remain an under-appreciated and unquantified factor in determining the risks that tropical ecosystems face. In this presentation, we simulate the effects of a wet canopy on satellite-based microwave backscatter by modifying the Michigan Microwave Canopy Scattering Model to account for the presence of dew droplets. We apply this model to estimate the canopy water storage derived from the SeaWinds Scatterometer aboard the QuikSCAT satellite by comparing the 6AM and 6PM microwave retrievals. We examine dew frequency and amount in tropical forests in South America, Africa and South-East Asia. Using the 10 years of available data, we investigate trends in dew formation in these three areas and speculate on the potential impact of the observed changes on dew-dependent tropical ecosystems.Finally, we compare our results to locally measured and modeled leaf wetness data. With multiple recently-launched instruments providing new data, strong correlations between satellite-based canopy water storage and in-situ data indicate the possibility of novel applications of microwave backscatter datasets in closed canopies ecosystems, such as the estimation of canopy interception or leaf-water content.

  3. A microfluidic thermometer: Precise temperature measurements in microliter- and nanoliter-scale volumes

    PubMed Central

    McKenzie, Brittney A.

    2017-01-01

    Measuring the temperature of a sample is a fundamental need in many biological and chemical processes. When the volume of the sample is on the microliter or nanoliter scale (e.g., cells, microorganisms, precious samples, or samples in microfluidic devices), accurate measurement of the sample temperature becomes challenging. In this work, we demonstrate a technique for accurately determining the temperature of microliter volumes using a simple 3D-printed microfluidic chip. We accomplish this by first filling “microfluidic thermometer” channels on the chip with substances with precisely known freezing/melting points. We then use a thermoelectric cooler to create a stable and linear temperature gradient along these channels within a measurement region on the chip. A custom software tool (available as online Supporting Information) is then used to find the locations of solid-liquid interfaces in the thermometer channels; these locations have known temperatures equal to the freezing/melting points of the substances in the channels. The software then uses the locations of these interfaces to calculate the temperature at any desired point within the measurement region. Using this approach, the temperature of any microliter-scale on-chip sample can be measured with an uncertainty of about a quarter of a degree Celsius. As a proof-of-concept, we use this technique to measure the unknown freezing point of a 50 microliter volume of solution and demonstrate its feasibility on a 400 nanoliter sample. Additionally, this technique can be used to measure the temperature of any on-chip sample, not just near-zero-Celsius freezing points. We demonstrate this by using an oil that solidifies near room temperature (coconut oil) in a microfluidic thermometer to measure on-chip temperatures well above zero Celsius. By providing a low-cost and simple way to accurately measure temperatures in small volumes, this technique should find applications in both research and educational

  4. High temperature solar thermal technology

    NASA Technical Reports Server (NTRS)

    Leibowitz, L. P.; Hanseth, E. J.; Peelgren, M. L.

    1980-01-01

    Some advanced technology concepts under development for high-temperature solar thermal energy systems to achieve significant energy cost reductions and performance gains and thus promote the application of solar thermal power technology are presented. Consideration is given to the objectives, current efforts and recent test and analysis results in the development of high-temperature (950-1650 C) ceramic receivers, thermal storage module checker stoves, and the use of reversible chemical reactions to transport collected solar energy. It is pointed out that the analysis and testing of such components will accelerate the commercial deployment of solar energy.

  5. Distribution of skin temperature in Mexican children.

    PubMed

    Kolosovas-Machuca, Eleazar Samuel; González, Francisco Javier

    2011-08-01

    Infrared thermography can be a valuable diagnostic tool in the evaluation and management of several pathologies; however, the temperature pattern of the healthy body should be known in order to perform a more precise clinical evaluation. A total of 25 healthy children (10 female and 15 male) were examined with a thermographic camera. Eighty-four temperature points of the body were recorded, saved in a database, and analyzed. The measurements showed that the forehead, neck, and the cervical area have the highest average temperatures of the whole body, and that the temperature distribution between boys and girls is very similar. The difference in skin temperature along the y-axis of the body varied up to 5.1°C; however, the average difference in skin temperature along the x-axis of the body was 0.7°C. These temperature variations observed in children are lower than the ones reported for adults, which could be due to a greater variation of body fat distribution in adults. This study shows that thermography could be a good tool for disease diagnosis in children as there is a lower skin temperature variation among children than among adults. © 2011 John Wiley & Sons A/S.

  6. Temperature-Dependent Electrical Conductivity of GeTe-Based RF Switches

    DTIC Science & Technology

    2015-03-31

    Short, high temperature pulses result in a melt -quench cycle, amorphizing the GeTe and leaving the switch in the electrically insulating OFF state...Longer, lower temperature pulses result in the recrystallization of the GeTe, leaving the switch in the electrically conductive ON state. The...shown to vary only weakly with temperature. OFF-state S-parameters also exhibit slight temperature variation, with an inflection point of ~175

  7. Single Particle Studies of Heterogeneous Atmospheric Chemistry on Aluminum Oxide Particles in a Quadrupole Trap

    DTIC Science & Technology

    2000-03-01

    For Figures 17 and 18, the H20 content of the N2 gas flow is ណ ppm ( dew point < 220 K); for Figure 19, the HC1 content of the gas stream is 30 ppm...the same temperature to prevent supersaturation. We have calibrated the water delivery system in H2S04 trapping experiments, 35 by a dew point ...We have investigated the activities of different types of aluminum oxide particles for uptake of gas -phase H20 and HCI. The particle types

  8. Improving indoor air quality through the use of continual multipoint monitoring of carbon dioxide and dew point.

    PubMed

    Bearg, D W

    1998-09-01

    This article summarizes an approach for improving the indoor air quality (IAQ) in a building by providing feedback on the performance of the ventilation system. The delivery of adequate quantities of ventilation to all building occupants is necessary for the achievement of good IAQ. Feedback on the performance includes information on the adequacy of ventilation provided, the effectiveness of the distribution of this air, the adequacy of the duration of operation of the ventilation system, and the identification of leakage into the return plenum, either of outdoor or supply air. Keeping track of ventilation system performance is important not only in terms of maintaining good IAQ, but also making sure that this system continues to perform as intended after changes in building use. Information on the performance of the ventilation system is achieved by means of an automated sampling system that draws air from multiple locations and delivers it to both a carbon dioxide monitor and dew point sensor. The use of single shared sensors facilitates calibration checks as well as helps to guarantee data integrity. This approach to monitoring a building's ventilation system offers the possibility of achieving sustainable performance of this important aspect of good IAQ.

  9. Formation of temperature front in stably stratified turbulence

    NASA Astrophysics Data System (ADS)

    Kimura, Yoshifumi; Sullivan, Peter; Herring, Jackson

    2016-11-01

    An important feature of stably stratified turbulence is the significant influence of internal gravity waves which makes stably stratified turbulence unique compared to homogeneous isotropic turbulence. In this paper, we investigate the genesis of temperature fronts-a crucial subject both practically and fundamentally-in stably stratified turbulence using Direct Numerical Simulations (DNS) of the Navier-Stokes equation under the Boussinesq approximation with 10243 grid points. Vertical profiles of temperature fluctuations show almost vertically periodic sawtooth wavy structures with negative and positive layers stacked together with clear boundaries implying a sharp temperature fronts. The sawtooth waves consist of gradual decreasing temperature fluctuations with rapid recovery to a positive value as the frontal boundary is crossed vertically. This asymmetry of gradients comes from the structure that warm temperature region lies on top of cool temperature region, and can be verified in the skewed probability density function (PDF) of vertical temperature gradient. We try to extract the flow structures and mechanism for the formation and maintenance of the strong temperature front numerically.

  10. Optical fiber distributed temperature sensor in cardiological surgeries

    NASA Astrophysics Data System (ADS)

    Skapa, Jan; Látal, Jan; Penhaker, Marek; Koudelka, Petr; Hancek, František; Vasinek, Vladimír

    2010-04-01

    In those days a lot of cardiological surgeries is made every day. It is a matter of very significant importance keeping the temperature of the hearth low during the surgery because it decides whether the cells of the muscle will die or not. The hearth is cooled by the ice placed around the hearth muscle during the surgery and cooling liquid is injected into the hearth also. In these days the temperature is measured only in some points of the hearth using sensors based on the pH measurements. This article describes new method for measurement of temperature of the hearth muscle during the cardiological surgery. We use a multimode optical fiber and distributed temperature sensor (DTS) based on the stimulated Raman scattering in temperature measurements. This principle allows us to measure the temperature and to determine where the temperature changes during the surgery. Resolution in the temperature is about 0.1 degrees of Celsius. Resolution in length is about 1 meter. The resolution in length implies that the fiber must be wound to ensure the spatial resolution about 5 by 5 centimeters.

  11. Propagation of sound through the Earth's atmosphere

    NASA Technical Reports Server (NTRS)

    Meredith, R. W.; Becher, J.

    1983-01-01

    The data collected at a pressure of one atmosphere for the different temperatures and relative humidities of the air-water vapor mixtures is summarized. The dew point hygrometer used in these measurements did not give reliable results for dew points much above the ambient room temperature. For this reason measurements were not attempted at the higher temperatures and humidities. Viscous wall losses in the resonant tube at 0 C so dominate the molecular relaxation of nitrogen, in the air-water vapor mixture, that reliable data could not be obtained using the free decay method in a resonant tube at one atmosphere. In an effort to obtain viable data at these temperatures, measurements were performed at a pressure of 10 atmospheres. Since the molecular relaxation peak is proportional to the pressure and the viscous losses are proportional to the inverse square root of the pressure the peak height should be measurable at the higher pressure. The tradeoff here is that at 10 atmospheres; the highest relative humidity attainable is 10 percent. The data collected at 10 atmospheres is also summarized.

  12. Room temperature ionic liquids: A simple model. Effect of chain length and size of intermolecular potential on critical temperature.

    PubMed

    Chapela, Gustavo A; Guzmán, Orlando; Díaz-Herrera, Enrique; del Río, Fernando

    2015-04-21

    A model of a room temperature ionic liquid can be represented as an ion attached to an aliphatic chain mixed with a counter ion. The simple model used in this work is based on a short rigid tangent square well chain with an ion, represented by a hard sphere interacting with a Yukawa potential at the head of the chain, mixed with a counter ion represented as well by a hard sphere interacting with a Yukawa potential of the opposite sign. The length of the chain and the depth of the intermolecular forces are investigated in order to understand which of these factors are responsible for the lowering of the critical temperature. It is the large difference between the ionic and the dispersion potentials which explains this lowering of the critical temperature. Calculation of liquid-vapor equilibrium orthobaric curves is used to estimate the critical points of the model. Vapor pressures are used to obtain an estimate of the triple point of the different models in order to calculate the span of temperatures where they remain a liquid. Surface tensions and interfacial thicknesses are also reported.

  13. 40 CFR 91.313 - Analyzers required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  14. 40 CFR 90.313 - Analyzers required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  15. 40 CFR 90.313 - Analyzers required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  16. 40 CFR 91.313 - Analyzers required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  17. 40 CFR 91.313 - Analyzers required.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  18. 40 CFR 91.313 - Analyzers required.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  19. 40 CFR 90.313 - Analyzers required.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  20. 40 CFR 90.313 - Analyzers required.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... condensation is acceptable. If water is removed by condensation, the sample gas temperature or sample dew point.... A water trap performing this function is an acceptable method. Means other than condensation may be...

  1. Minimum Temperatures, Diurnal Temperature Ranges and Temperature Inversions in Limestone Sinkholes of Different Sizes and Shapes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Whiteman, Charles D.; Haiden, Thomas S.; Pospichal, Bernhard

    2004-08-01

    Air temperature data from five enclosed limestone sinkholes of various sizes and shapes on the 1300 m MSL Duerrenstein Plateau near Lunz, Austria have been analyzed to determine the effect of sinkhole geometry on temperature minima, diurnal temperature ranges, temperature inversion strengths and vertical temperature gradients. Data were analyzed for a non-snow-covered October night and for a snow-covered December night when the temperature fell as low as -28.5°C. Surprisingly, temperatures were similar in two sinkholes with very different drainage areas and depths. A three-layer model was used to show that the sky-view factor is the most important topographic parameter controllingmore » cooling for basins in this size range and that the cooling slows when net longwave radiation at the floor of the sinkhole is nearly balanced by the ground heat flux.« less

  2. New Method of Filling of High-Temperature Fixed-Point Cells Based on Metal-Carbon Eutectics/Peritectics

    NASA Astrophysics Data System (ADS)

    Khlevnoy, B. B.; Grigoryeva, I. A.; Ibragimov, N. A.

    2011-08-01

    A new method of filling of high-temperature fixed-point cells based on metal-carbon eutectics and peritectics is suggested and tested. In this method a metal and carbon powder mixture is introduced not directly into the crucible, but into an additional container located just above the crucible. The mixture melts inside the container, and the already molten eutectic drops through a small hole in the bottom of the container and fills the crucible drop by drop. The method can be used to obtain a uniform ingot without porous or foundry cavities, to minimize the risk of contamination, and to avoid some other disadvantages. The method was applied to fabricate Re-C and WC-C cells using 5N purity materials. The cells demonstrated a good plateau shape with melting ranges of 0.2 K and 80 mK for Re-C and WC-C, respectively. The Re-C cell was compared with a cell built at NMIJ and showed good agreement with a difference of melting temperatures of only 45 mK.

  3. Temperature-dependent thermal conductivities of 1D semiconducting nanowires via four-point-probe 3-ω method.

    PubMed

    Lee, Seung-Yong; Lee, Mi-Ri; Park, No-Won; Kim, Gil-Sung; Choi, Heon-Jin; Choi, Tae-Youl; Lee, Sang-Kwon

    2013-12-13

    We report on a systematic study of the thermal transport characteristics of both as-grown zinc oxide and gallium nitride nanowires (NWs) via the four-point-probe 3-ω method in the temperature range 130-300 K. Both as-grown NWs were synthesized by a vapor-liquid-solid growth mechanism, and show clear n-type semiconducting behavior without any defects, which enables both the NWs to be promising candidates for thermoelectric materials. To measure the thermal conductivities of both NWs with lower heat loss and measurement errors, the suspended structures were formed by a combination of an e-beam lithography process and a random dispersion method. The measured thermal conductivities of both NWs are greatly reduced compared to their bulk materials due to the enhanced phonon scattering via the size effect and dopants (impurities). Furthermore, we observed that the Umklapp peaks of both NWs are shifted to a higher temperature than those of their bulk counterparts, indicating that phonon-boundary scattering dominates over other phonon scattering due to the size effect.

  4. Low-temperature hermetic sealing of optical fiber components

    DOEpatents

    Kramer, D.P.

    1996-10-22

    A method for manufacturing low-temperature hermetically sealed optical fiber components is provided. The method comprises the steps of: inserting an optical fiber into a housing, the optical fiber having a glass core, a glass cladding and a protective buffer layer disposed around the core and cladding; heating the housing to a predetermined temperature, the predetermined temperature being below a melting point for the protective buffer layer and above a melting point of a solder; placing the solder in communication with the heated housing to allow the solder to form an eutectic and thereby fill a gap between the interior of the housing and the optical fiber; and cooling the housing to allow the solder to form a hermetic compression seal between the housing and the optical fiber. 5 figs.

  5. Low-temperature hermetic sealing of optical fiber components

    DOEpatents

    Kramer, Daniel P.

    1996-10-22

    A method for manufacturing low-temperature hermetically sealed optical fi components is provided. The method comprises the steps of: inserting an optical fiber into a housing, the optical fiber having a glass core, a glass cladding and a protective buffer layer disposed around the core and cladding; heating the housing to a predetermined temperature, the predetermined temperature being below a melting point for the protective buffer layer and above a melting point of a solder; placing the solder in communication with the heated housing to allow the solder to form an eutectic and thereby fill a gap between the interior of the housing and the optical fiber; and cooling the housing to allow the solder to form a hermetic compression seal between the housing and the optical fiber.

  6. Temperature threshold models for benthic macroinvertebrates in Idaho wadeable streams and neighboring ecoregions.

    PubMed

    Richards, David C; Lester, Gary; Pfeiffer, John; Pappani, Jason

    2018-02-07

    Water temperatures are warming throughout the world including the Pacific Northwest, USA. Benthic macroinvertebrates are one of the most important and widely used indicators of freshwater impairment; however, their response to increased water temperatures and their use for monitoring water temperature impairment has been hindered by lack of knowledge of temperature occurrences, threshold change points, or indicator taxa. We present new analysis of a large macroinvertebrate database provided by Idaho Department of Environmental Quality from wadeable streams in Idaho that is to be used in conjunction with our previous analyses. This new analysis provides threshold change points for over 400 taxa along an increasing temperature gradient and provides a list of statistically important indicator taxa. The macroinvertebrate assemblage temperature change point for the taxa that decreased with increased temperatures was determined to be about 20.5 °C and for the taxa assemblage that increased with increased temperatures was about 11.5 °C. Results of this new analysis combined with our previous analysis will also be useful for others in neighboring regions where these taxa occur.

  7. High temperature materials characterization

    NASA Technical Reports Server (NTRS)

    Workman, Gary L.

    1990-01-01

    A lab facility for measuring elastic moduli up to 1700 C was constructed and delivered. It was shown that the ultrasonic method can be used to determine elastic constants of materials from room temperature to their melting points. The ease in coupling high frequency acoustic energy is still a difficult task. Even now, new coupling materials and higher power ultrasonic pulsers are being suggested. The surface was only scratched in terms of showing the full capabilities of either technique used, especially since there is such a large learning curve in developing proper methodologies to take measurements into the high temperature region. The laser acoustic system does not seem to have sufficient precision at this time to replace the normal buffer rod methodology.

  8. Temperature gating and competing temperature-dependent effects in DNA molecular wires

    NASA Astrophysics Data System (ADS)

    Wibowo, Denni; Narenji, Alaleh; Kassegne, Sam

    2017-02-01

    While recent research in electron-transport mechanism on a double strands DNA seems to converge into a consensus, experiments in direct electrical measurements on a long DNA molecules still lead to a conflicting result This study is the continuation of our previous research in electrical characterization of DNA molecular wires, where we furtherly investigate the effects of temperature on the electrical conductivity of DNA molecular wires by measuring its impedance response. We found that at higher temperatures, the expected increase in charge hopping mechanism may account for the decrease in impedance (and hence increase in conductivity) supporting the 'charge hopping mechanism' theory. UV light exposure, on the other hand, causes damage to GC base pairs reducing the path available for hopping mechanism and hence resulting in increased impedance - this again supporting the 'charge hopping mechanism' theory. We also report that λ-DNA molecular wires have differing impedance responses at two temperature regimes: impedance increases between 4 °C - 40 °C and then decreases between 40 °C - melting point (˜110 °C), after which λ-DNA denatures resulting in no current transduction. We submit that the low impedance of λ-DNA molecular wires observed at moderate to high frequencies may have significant implications to the field of DNA-based bionanoelectronics.

  9. Evaluation of Surface Fatigue Strength Based on Surface Temperature

    NASA Astrophysics Data System (ADS)

    Deng, Gang; Nakanishi, Tsutomu

    Surface temperature is considered to be an integrated index that is dependent on not only the load and the dimensions at the contact point but also the sliding velocity, rolling velocity, surface roughness, and lubrication conditions. Therefore, the surface durability of rollers and gears can be evaluated more exactly and simply by the use of surface temperature rather than Hertzian stress. In this research, surface temperatures of rollers under different rolling and sliding conditions are measured using a thermocouple. The effects of load P, mean velocity Vm and sliding velocity Vs on surface temperature are clarified. An experimental formula, which expresses the linear relationship between surface temperature and the P0.86Vs1.31Vm-0.83 value, is used to determine surface temperature. By comparing calculated and measured temperature on the tooth surface of a gear, this formula is confirmed to be applicable for gear tooth surface temperature calculation.

  10. Parametric analysis of parameters for electrical-load forecasting using artificial neural networks

    NASA Astrophysics Data System (ADS)

    Gerber, William J.; Gonzalez, Avelino J.; Georgiopoulos, Michael

    1997-04-01

    Accurate total system electrical load forecasting is a necessary part of resource management for power generation companies. The better the hourly load forecast, the more closely the power generation assets of the company can be configured to minimize the cost. Automating this process is a profitable goal and neural networks should provide an excellent means of doing the automation. However, prior to developing such a system, the optimal set of input parameters must be determined. The approach of this research was to determine what those inputs should be through a parametric study of potentially good inputs. Input parameters tested were ambient temperature, total electrical load, the day of the week, humidity, dew point temperature, daylight savings time, length of daylight, season, forecast light index and forecast wind velocity. For testing, a limited number of temperatures and total electrical loads were used as a basic reference input parameter set. Most parameters showed some forecasting improvement when added individually to the basic parameter set. Significantly, major improvements were exhibited with the day of the week, dew point temperatures, additional temperatures and loads, forecast light index and forecast wind velocity.

  11. Characterization of air temperature in modern ion chambers due to phantom geometry and ambient temperature changes.

    PubMed

    Saenz, Daniel L; Kirby, Neil; Gutiérrez, Alonso N

    2016-07-01

    Temperature and pressure corrections are necessary to account for the varying mass of air in the sensitive volume of a vented ionization chamber (IC) when performing absolute dose measurements. Locations commonly used to measure the presumed IC air temperature may not accurately represent the chamber cavity air temperature, and phantoms undergoing temperature changes further compound the problem. Prior studies have characterized thermal equilibrium in separate phantoms for Farmer chambers alone. However, the purpose of this study was to characterize the cavity air temperature dependence on changes in the ambient temperature and phantom geometry configuration for a wider and more modern variety of chambers to determine if previously published wait times apply to these chambers as well. Thermal conduction properties were experimentally investigated by modifying a PTW 0.3 cm(3) Semiflex IC with a thermocouple replacing the central electrode. Air cavity temperature versus time was recorded in three phantom geometries characteristic of common absolute dose measurements. The phantoms were (15 ± 1) °C before measurement with an IC at the treatment vault temperature of (21 ± 1) °C. Simulations were conducted to provide a theoretical basis for the measurements and to simulate temperature response of a PTW PinPoint® and Farmer chamber. The simulation methods were first validated by comparison with measured Semiflex chamber thermal response curves before extension to the other chambers. Two thermal equilibria curves were recorded on different time scales. IC temperature initially dropped to the colder phantom temperature but subsequently increased as the phantom itself equilibrated with the warmer room temperature. In a large phantom of dimensions (25.5 × 25.5 × 23.4) cm(3), 3 min was required before the IC temperature reached within 0.5 °C of its equilibrium within the phantom. Similarly, wait times of 2 min were needed for 7.5 and 2 cm slab phantoms. Recording

  12. Material Problems in Using High-Temperature Thermocouples

    NASA Astrophysics Data System (ADS)

    Edler, F.

    2011-08-01

    The material compatibility and thermal stability of ceramic-composite coatings of different oxide ceramics deposited on alumina tubes to prevent the reduction of the alumina were investigated in the high-temperature range between 1750 °C and 1850 °C. It turned out that the coatings were thermally unstable and did not provide adequate protection against the reduction of the alumina tubes. The oxide ceramics formed eutectic compositions with low melting temperatures and were also prone to reduction to elementary metals by carbon. A new type of high-temperature thermocouple on the basis of refractory and noble metals was tested in the temperature range between 1325 °C and 1800 °C. Two metal-sheathed prototypes were constructed. The thermoelectric behavior of the tungsten5%rhenium/iridium thermocouples (W5%Re/Ir) was investigated by different high-temperature exposures, and the thermoelectric stability was checked by repeated measurements at the ice point.

  13. Thermocouple design for measuring temperatures of small insects

    Treesearch

    A.A. Hanson; R.C. Venette

    2013-01-01

    Contact thermocouples often are used to measure surface body temperature changes of insects during cold exposure. However, small temperature changes of minute insects can be difficult to detect, particularly during the measurement of supercooling points. We developed two thermocouple designs, which use 0.51 mm diameter or 0.127 mm diameter copper-constantan wires, to...

  14. Microclimate environmental parameters indexed for Sudden Oak death in Georgia and South Carolina

    Treesearch

    Pauline Spaine; William J. Otrosina; Stanley J. Zarnoch; Sharon V. Lumpkin

    2008-01-01

    We monitored Ericaceous habitat in Georgia and South Carolina for temperature, dew point and humidity ranges throughout a two year period. Temperature and humidity data were used to characterize their range in Georgia and South Carolina where potential SOD susceptible hosts occur. This data suggests risk for SOD development may be more widespread in southeastern forest...

  15. The effects of spatial sampling choices on MR temperature measurements.

    PubMed

    Todd, Nick; Vyas, Urvi; de Bever, Josh; Payne, Allison; Parker, Dennis L

    2011-02-01

    The purpose of this article is to quantify the effects that spatial sampling parameters have on the accuracy of magnetic resonance temperature measurements during high intensity focused ultrasound treatments. Spatial resolution and position of the sampling grid were considered using experimental and simulated data for two different types of high intensity focused ultrasound heating trajectories (a single point and a 4-mm circle) with maximum measured temperature and thermal dose volume as the metrics. It is demonstrated that measurement accuracy is related to the curvature of the temperature distribution, where regions with larger spatial second derivatives require higher resolution. The location of the sampling grid relative temperature distribution has a significant effect on the measured values. When imaging at 1.0 × 1.0 × 3.0 mm(3) resolution, the measured values for maximum temperature and volume dosed to 240 cumulative equivalent minutes (CEM) or greater varied by 17% and 33%, respectively, for the single-point heating case, and by 5% and 18%, respectively, for the 4-mm circle heating case. Accurate measurement of the maximum temperature required imaging at 1.0 × 1.0 × 3.0 mm(3) resolution for the single-point heating case and 2.0 × 2.0 × 5.0 mm(3) resolution for the 4-mm circle heating case. Copyright © 2010 Wiley-Liss, Inc.

  16. Influences of end-point heating temperature on the quality attributes of chicken meat.

    PubMed

    Chumngoen, W; Chen, C F; Chen, H Y; Tan, F J

    2016-12-01

    This study aimed to evaluate the changes in physicochemical, textural and sensory characteristics of broiler (BR) and Taiwan native chicken (TNC) pectoralis muscle heated at temperatures of 50-95°C. With increasing temperature, cooking loss, collagen solubility, shear force value and hardness, of samples increased in both chicken breeds. Rapid decreases in protein solubility were observed when the meat was heated to 50°C and gradually decreased thereafter. Meat from BRs and native chickens performed differently upon heating in certain characteristics. TNC meat had longer cooking time and lower myofibrillar fragmentation index than BR meat did. TNC meat had higher collagen content, shear force values and springiness but lower collagen solubility than BR meat did. BR meat had significantly higher onset and end transition temperatures than TNC meat did. In BR meat, a sensory analysis revealed that moisture release decreased and chicken flavour increased with increasing temperature. Protein solubility, cooking loss and the texture of heated meat were highly correlated. This study scientifically assessed the performances of the two breeds of chickens with different thermal treatments; producers could utilise the information to produce poultry products with more desirable qualities.

  17. Temperature Dependence of Arn+ Cluster Backscattering from Polymer Surfaces: a New Method to Determine the Surface Glass Transition Temperature.

    PubMed

    Poleunis, Claude; Cristaudo, Vanina; Delcorte, Arnaud

    2018-01-01

    In this work, time-of-flight secondary ion mass spectrometry (ToF-SIMS) was used to study the intensity variations of the backscattered Ar n + clusters as a function of temperature for several amorphous polymer surfaces (polyolefins, polystyrene, and polymethyl methacrylate). For all these investigated polymers, our results show a transition of the ratio Ar 2 + /(Ar 2 + + Ar 3 + ) when the temperature is scanned from -120 °C to +125 °C (the exact limits depend on the studied polymer). This transition generally spans over a few tens of degrees and the temperature of the inflection point of each curve is always lower than the bulk glass transition temperature (T g ) reported for the considered polymer. Due to the surface sensitivity of the cluster backscattering process (several nanometers), the presented analysis could provide a new method to specifically evaluate a surface transition temperature of polymers, with the same lateral resolution as the gas cluster beam. Graphical abstract ᅟ.

  18. Non-hoop winding effect on bonding temperature of laser assisted tape winding process

    NASA Astrophysics Data System (ADS)

    Zaami, Amin; Baran, Ismet; Akkerman, Remko

    2018-05-01

    One of the advanced methods for production of thermoplastic composite methods is laser assisted tape winding (LATW). Predicting the temperature in LATW process is very important since the temperature at nip-point (bonding line through width) plays a pivotal role in a proper bonding and hence the mechanical performance. Despite the hoop-winding where the nip-point is the straight line, non-hoop winding includes a curved nip-point line. Hence, the non-hoop winding causes somewhat a different power input through laser-rays and-reflections and consequently generates unknown complex temperature profile on the curved nip-point line. Investigating the temperature at the nip-point line is the point of interest in this study. In order to understand this effect, a numerical model is proposed to capture the effect of laser-rays and their reflections on the nip-point temperature. To this end, a 3D optical model considering the objects in LATW process is considered. Then, the power distribution (absorption and reflection) from the optical analysis is used as an input (heat flux distribution) for the thermal analysis. The thermal analysis employs a fully-implicit advection-diffusion model to calculate the temperature on the surfaces. The results are examined to demonstrate the effect of winding direction on the curved nip-point line (tape width) which has not been considered in literature up to now. Furthermore, the results can be used for designing a better and more efficient setup in the LATW process.

  19. Influence of Gas Atmosphere Dew Point on the Selective Oxidation and the Reactive Wetting During Hot Dip Galvanizing of CMnSi TRIP Steel

    NASA Astrophysics Data System (ADS)

    Cho, Lawrence; Lee, Seok Jae; Kim, Myung Soo; Kim, Young Ha; De Cooman, Bruno C.

    2013-01-01

    The selective oxidation and reactive wetting of intercritically annealed Si-bearing CMnSi transformation-induced plasticity steels were investigated by high-resolution transmission electron microscopy. In a N2 + 10 pct H2 gas atmosphere with a dew point (DP) ranging from 213 K to 278 K (-60 °C to 5 °C), a continuous layer of selective oxides was formed on the surface. Annealing in a higher DP gas atmosphere resulted in a thinner layer of external oxidation and a greater depth of internal oxidation. The hot dipping was carried out in a Zn bath containing 0.22 mass pct Al, and the bath temperature was 733 K (460 °C). Coarse and discontinuous Fe2Al5- x Zn x grains and Fe-Zn intermetallics (ζ and δ) were observed at the steel/coating interface after the hot dip galvanizing (HDG) of panels were annealed in a low DP atmosphere 213 K (-60 °C). The Fe-Zn intermetallics were formed both in areas where the Fe2Al5- x Zn x inhibition layer had not been formed and on top of non-stoichiometric Fe-Al-Zn crystals. Poor wetting was observed on panels annealed in a low DP atmosphere because of the formation of thick film-type oxides on the surface. After annealing in higher DP gas atmospheres, i.e., 263 K and 278 K (-10 °C and 5 °C), a continuous and fine-grained Fe2Al5- x Zn x layer was formed. No Fe-Zn intermetallics were formed. The small grain size of the inhibition layer was attributed to the nucleation of the Fe2Al5- x Zn x grains on small ferrite sub-surface grains and the presence of granular surface oxides. A high DP atmosphere can therefore significantly contribute to the decrease of Zn-coating defects on CMnSi TRIP steels processed in HDG lines.

  20. Project Fog Drops. Part 1: Investigations of warm fog properties

    NASA Technical Reports Server (NTRS)

    Pilie, R. J.; Eadie, W.; Mack, E. J.; Rogers, C.; Kocmond, W. C.

    1972-01-01

    A detailed study was made of the micrometeorological and microphysical characteristics of eleven valley fogs occurring near Elmira, New York. Observations were made of temperature, dew point, wind speed and direction, dew deposition, vertical wind velocity, and net radiative flux. In fog, visibility was continuously recorded and periodic measurements were made of liquid water content and drop-size distribution. The observations were initiated in late evening and continued until the time of fog dissipation. The vertical distribution of temperature in the lowest 300 meters and cloud nucleus concentration at several heights were measured from an aircraft before fog nucleus concentrations at several heights were measured from an aircraft before fog formation. A numerical model was developed to investigate the life cycle of radiation fogs. The model predicts the temporal evolution of the vertical distributions of temperature, water vapor, and liquid water as determined by the turbulent transfer of heat and moisture. The model includes the nocturnal cooling of the earth's surface, dew formation, fog drop sedimentation, and the absorption of infrared radiation by fog.

  1. High-Temperature Solar Cell Development

    NASA Technical Reports Server (NTRS)

    Landis, Geoffrey A.; Raffaelle, Ryne P.; Merritt, Danielle

    2004-01-01

    The vast majority of satellites and near-earth probes developed to date have relied upon photovoltaic power generation. If future missions to probe environments close to the sun will be able to use photovoltaic power, solar cells that can function at high temperatures, under high light intensity, and high radiation conditions must be developed. For example, the equilibrium temperature of a Mercury surface station will be about 450 C, and the temperature of solar arrays on the proposed "Solar Probe" mission will extend to temperatures as high as 2000 C (although it is likely that the craft will operate on stored power rather than solar energy during the closest approach to the sun). Advanced thermal design principles, such as replacing some of the solar array area with reflectors, off-pointing, and designing the cells to reflect rather than absorb light out of the band of peak response, can reduce these operating temperature somewhat. Nevertheless, it is desirable to develop approaches to high-temperature solar cell design that can operate under temperature extremes far greater than today's cells. Solar cells made from wide bandgap (WBG) compound semiconductors are an obvious choice for such an application. In order to aid in the experimental development of such solar cells, we have initiated a program studying the theoretical and experimental photovoltaic performance of wide bandgap materials. In particular, we have been investigating the use of GaP, SiC, and GaN materials for space solar cells. We will present theoretical results on the limitations on current cell technologies and the photovoltaic performance of these wide-bandgap solar cells in a variety of space conditions. We will also give an overview of some of NASA's cell developmental efforts in this area and discuss possible future mission applications.

  2. From boiling point to glass transition temperature: transport coefficients in molecular liquids follow three-parameter scaling.

    PubMed

    Schmidtke, B; Petzold, N; Kahlau, R; Hofmann, M; Rössler, E A

    2012-10-01

    The phenomenon of the glass transition is an unresolved problem in condensed matter physics. Its prominent feature, the super-Arrhenius temperature dependence of the transport coefficients, remains a challenge to be described over the full temperature range. For a series of molecular glass formers, we combined τ(T) collected from dielectric spectroscopy and dynamic light scattering covering a range 10(-12) s < τ(T) < 10(2) s. Describing the dynamics in terms of an activation energy E(T), we distinguish a high-temperature regime characterized by an Arrhenius law with a constant activation energy E(∞) and a low-temperature regime for which E(coop)(T) ≡ E(T)-E(∞) increases exponentially while cooling. A scaling is introduced, specifically E(coop)(T)/E(∞) [proportionality] exp[-λ(T/T(A)-1)], where λ is a fragility parameter and T(A) a reference temperature proportional to E(∞). In order to describe τ(T) still the attempt time τ(∞) has to be specified. Thus, a single interaction parameter E(∞) describing the high-temperature regime together with λ controls the temperature dependence of low-temperature cooperative dynamics.

  3. Artificial Composites for High Temperature Applications; A Review (Composites Artificiels Destines a des Applications a Haute Temperature; Un Expose),

    DTIC Science & Technology

    1987-01-01

    71 6 Propagation of the recrystallization front in W-wire activated by Ni and Fe in the temperature range 1473 to 1923 K...composites. 73 9 Comparitive creep data for W - 1%ThO2 /FeCrAIY and DS eutectics . 73 10 Three point flexural strength in argon versus temperature for...particularly directionally solidified eutectics . In these composites the fibrous reinforcing phase is usually in chemical equilibrium with the

  4. Polymorphism of paracetamol: relative stabilities of the monoclinic and orthorhombic phases inferred from topological pressure-temperature and temperature-volume phase diagrams.

    PubMed

    Espeau, Philippe; Céolin, René; Tamarit, Josep-Lluis; Perrin, Marc-Antoine; Gauchi, Jean-Pierre; Leveiller, Franck

    2005-03-01

    The thermodynamic relationships between the two known polymorphs of paracetamol have been investigated, and the subsequent pressure-temperature and temperature-volume phase diagrams were constructed using data from crystallographic and calorimetric measurements as a function of the temperature. Irrespective of temperature, monoclinic Form I and orthorhombic Form II are stable phases at ordinary and high pressures, respectively. The I and II phase regions in the pressure-temperature diagram are bordered by the I-II equilibrium curve, for which a negative slope (dp/dT approximately -0.3 MPa x K(-1)) was determined although it was not observed experimentally. This curve goes through the I-II-liquid triple point whose coordinates (p approximately 234 MPa, T approximately 505 K) correspond to the crossing point of the melting curves, for which dp/dT values of +3.75 MPa x K(-1) (I) and +3.14 MPa x K(-1) (II) were calculated from enthalpy and volume changes upon fusion. More generally, this case exemplifies how the stability hierarchy of polymorphs may be inferred from the difference in their sublimation curves, as topologically positioned with respect to each other, using the phase rule and simple inferences resorting to Gibbs equilibrium thermodynamics. Copyright 2004 Wiley-Liss, Inc. and the American Pharmacists Association.

  5. Effect of peritoneal lavage solution temperature on body temperature in anaesthetised cats and small dogs.

    PubMed

    Barnes, D C; Leece, E A; Trimble, T A; Demetriou, J L

    2017-05-20

    A prospective, randomised, non-blinded, clinical study to assess the effect of peritoneal lavage using warmed fluid on body temperature in anesthetised cats and dogs of less than 10 kg body mass undergoing coeliotomy. A standardised anaesthetic protocol was used. Oesophageal and rectal temperatures were measured at various time points. At the end of surgery, group 1 patients (n=10) were lavaged with 200 ml/kg sterile isotonic saline at 34±1°C and group 2 (n=10) at 40±1°C. Groups were similar with respect to age, mass, body condition and surgical incision length. Duration of anaesthesia, surgical procedures and peritoneal lavage was similar between groups. Linear regression showed no significant change in oesophageal temperature during the lavage period for group 1 (P=0.64), but a significant increase for group 2 patients (P<0.0001), with mean temperature changes of -0.5°C (from (36.3°C to 35.9°C) and +0.9°C (from 35.4°C to 36.3°C), respectively. Similar results were found for rectal temperature, with mean changes of -0.5°C and +0.8°C (P=0.922 and 0.045), respectively. The use of isotonic crystalloid solution for peritoneal lavage at a temperature of 40±1°C significantly warms small animal patients, when applied in a clinical setting, compared with lavage solution at 34±1°C. British Veterinary Association.

  6. Lau phase interferometer for the measurement of the temperature and temperature profile of a gaseous flame

    NASA Astrophysics Data System (ADS)

    Shakher, Chandra; Thakur, Madhuri

    2001-05-01

    In this paper we have investigated the utility of Lau phase interferometer with white light source and circular gratings to measure temperature and temperature profile of an axisymmetric flame. In Lau phase interferometer the two gratings are separated by infinite distance. The third grating is placed at a distance Z equals n.p2(lambda) , (where n is an integer, d is the pitch of the grating and (lambda) is the wavelength of the white light source). The sensitivity of the system is determined by the pitch 'p' of the grating and the distance Z between the gratings. If the distance Z between the two gratings is increased to enhance the sensitivity, the accuracy of measurement is reduced because of the reduction in the fringe contrast. In white light Lau phase interferometer the fringe contrast can be improved by optimizing the self-image plane and the pitch of the grating. From the recorded interferogram the angle of deflection ((phi) ) is measured and temperature at a different point of the flame is calculated. The temperature measured using Lau phase interferometer is in good agreement with the temperature measured by thermocouple and dataloger. Details of the theoretical analysis and experimental results are presented.

  7. Air Modeling - Observational Meteorological Data

    EPA Pesticide Factsheets

    Observed meteorological data for use in air quality modeling consist of physical parameters that are measured directly by instrumentation, and include temperature, dew point, wind direction, wind speed, cloud cover, cloud layer(s), ceiling height,

  8. Delineation of soil temperature regimes from HCMM data

    NASA Technical Reports Server (NTRS)

    Day, R. L.; Petersen, G. W. (Principal Investigator)

    1982-01-01

    The subsetting of HCMM data into ORSER format was completed for four dates using a modified SUBSET program. Large areas (approximately 2500 scan lines, 1680 elements) were selected to increase the occurrence of suitable control points for registration. Average daily temperatures (ADT) were calculated for each date. The MERGE program combined registered daytime temperature (DAY-IR) with nighttime temperature (NIGHT-IR) to form a separate two-channel data set. The SUBTRAN program averaged the DAY-IR and NIGHT-IR creating a third ADT channel. Registration equations for the four ADT data sets were generated. A one dimensional soil heat flow equation was modified to allow for mean annual soil temperature predictions using merged ADT data sets.

  9. Shell structures in aluminum nanocontacts at elevated temperatures

    PubMed Central

    2012-01-01

    Aluminum nanocontact conductance histograms are studied experimentally from room temperature up to near the bulk melting point. The dominant stable configurations for this metal show a very early crossover from shell structures at low wire diameters to ionic subshell structures at larger diameters. At these larger radii, the favorable structures are temperature-independent and consistent with those expected for ionic subshell (faceted) formations in face-centered cubic geometries. When approaching the bulk melting temperature, these local stability structures become less pronounced as shown by the vanishing conductance histogram peak structure. PMID:22325572

  10. Tropospheric temperature climatology and trends observed over the Middle East

    NASA Astrophysics Data System (ADS)

    Basha, Ghouse; Marpu, P. R.; Ouarda, T. B. M. J.

    2015-10-01

    In this study, we report for the first time, the upper air temperature climatology, and trends over the Middle East, which seem to be significantly affected by the changes associated with hot summer and low precipitation. Long term (1985-2012) radiosonde data from 12 stations are used to derive the mean temperature climatology and vertical trends. The study was performed by analyzing the data at different latitudes. The vertical profiles of air temperature show distinct behavior in terms of vertical and seasonal variability at different latitudes. The seasonal cycle of temperature at the 100 hPa, however, shows an opposite pattern compared to the 200 hPa levels. The temperature at 100 hPa shows a maximum during winter and minimum in summer. Spectral analysis shows that the annual cycle is dominant in comparison with the semiannual cycle. The time-series of temperature data was analyzed using the Bayesian change point analysis and cumulative sum method to investigate the changes in temperature trends. Temperature shows a clear change point during the year 1999 at all stations. Further, Modified Mann-Kendall test was applied to study the vertical trend, and analysis shows statistically significant lower tropospheric warming and cooling in upper troposphere after the year 1999. In general, the magnitude of the trend decreases with altitude in the troposphere. In all the latitude bands in lower troposphere, significant warming is observed, whereas at higher altitudes cooling is noticed based on 28 years temperature observations over the Middle East.

  11. Initial fuel temperature effects on burning rate of pool fire.

    PubMed

    Chen, Bing; Lu, Shou-Xiang; Li, Chang-Hai; Kang, Quan-Sheng; Lecoustre, Vivien

    2011-04-15

    The influence of the initial fuel temperature on the burning behavior of n-heptane pool fire was experimentally studied at the State Key Laboratory of Fire Science (SKLFS) large test hall. Circular pool fires with diameters of 100mm, 141 mm, and 200 mm were considered with initial fuel temperatures ranging from 290 K to 363 K. Burning rate and temperature distributions in fuel and vessel wall were recorded during the combustion. The burning rate exhibited five typical stages: initial development, steady burning, transition, bulk boiling burning, and decay. The burning rate during the steady burning stage was observed to be relatively independent of the initial fuel temperature. In contrast, the burning rate of the bulk boiling burning stage increases with increased initial fuel temperature. It was also observed that increased initial fuel temperature decreases the duration of steady burning stage. When the initial temperature approaches the boiling point, the steady burning stage nearly disappears and the burning rate moves directly from the initial development stage to the transition stage. The fuel surface temperature increases to its boiling point at the steady burning stage, shortly after ignition, and the bulk liquid reaches boiling temperature at the bulk boiling burning stage. No distinguished cold zone is formed in the fuel bed. However, boiling zone is observed and the thickness increases to its maximum value when the bulk boiling phenomena occurs. Copyright © 2011 Elsevier B.V. All rights reserved.

  12. Fiber Bragg Grating Based System for Temperature Measurements

    NASA Astrophysics Data System (ADS)

    Tahir, Bashir Ahmed; Ali, Jalil; Abdul Rahman, Rosly

    In this study, a fiber Bragg grating sensor for temperature measurement is proposed and experimentally demonstrated. In particular, we point out that the method is well-suited for monitoring temperature because they are able to withstand a high temperature environment, where standard thermocouple methods fail. The interrogation technologies of the sensor systems are all simple, low cost and effective as well. In the sensor system, fiber grating was dipped into a water beaker that was placed on a hotplate to control the temperature of water. The temperature was raised in equal increments. The sensing principle is based on tracking of Bragg wavelength shifts caused by the temperature change. So the temperature is measured based on the wavelength-shifts of the FBG induced by the heating water. The fiber grating is high temperature stable excimer-laser-induced grating and has a linear function of wavelength-temperature in the range of 0-285°C. A dynamic range of 0-285°C and a sensitivity of 0.0131 nm/°C almost equal to that of general FBG have been obtained by this sensor system. Furthermore, the correlation of theoretical analysis and experimental results show the capability and feasibility of the purposed technique.

  13. Accurate experimental determination of the isotope effects on the triple point temperature of water. I. Dependence on the 2H abundance

    NASA Astrophysics Data System (ADS)

    Faghihi, V.; Peruzzi, A.; Aerts-Bijma, A. T.; Jansen, H. G.; Spriensma, J. J.; van Geel, J.; Meijer, H. A. J.

    2015-12-01

    Variation in the isotopic composition of water is one of the major contributors to uncertainty in the realization of the triple point of water (TPW). Although the dependence of the TPW on the isotopic composition of the water has been known for years, there is still a lack of a detailed and accurate experimental determination of the values for the correction constants. This paper is the first of two articles (Part I and Part II) that address quantification of isotope abundance effects on the triple point temperature of water. In this paper, we describe our experimental assessment of the 2H isotope effect. We manufactured five triple point cells with prepared water mixtures with a range of 2H isotopic abundances encompassing widely the natural abundance range, while the 18O and 17O isotopic abundance were kept approximately constant and the 18O  -  17O ratio was close to the Meijer-Li relationship for natural waters. The selected range of 2H isotopic abundances led to cells that realised TPW temperatures between approximately  -140 μK to  +2500 μK with respect to the TPW temperature as realized by VSMOW (Vienna Standard Mean Ocean Water). Our experiment led to determination of the value for the δ2H correction parameter of A2H  =  673 μK / (‰ deviation of δ2H from VSMOW) with a combined uncertainty of 4 μK (k  =  1, or 1σ).

  14. Passive Resistor Temperature Compensation for a High-Temperature Piezoresistive Pressure Sensor.

    PubMed

    Yao, Zong; Liang, Ting; Jia, Pinggang; Hong, Yingping; Qi, Lei; Lei, Cheng; Zhang, Bin; Li, Wangwang; Zhang, Diya; Xiong, Jijun

    2016-07-22

    The main limitation of high-temperature piezoresistive pressure sensors is the variation of output voltage with operating temperature, which seriously reduces their measurement accuracy. This paper presents a passive resistor temperature compensation technique whose parameters are calculated using differential equations. Unlike traditional experiential arithmetic, the differential equations are independent of the parameter deviation among the piezoresistors of the microelectromechanical pressure sensor and the residual stress caused by the fabrication process or a mismatch in the thermal expansion coefficients. The differential equations are solved using calibration data from uncompensated high-temperature piezoresistive pressure sensors. Tests conducted on the calibrated equipment at various temperatures and pressures show that the passive resistor temperature compensation produces a remarkable effect. Additionally, a high-temperature signal-conditioning circuit is used to improve the output sensitivity of the sensor, which can be reduced by the temperature compensation. Compared to traditional experiential arithmetic, the proposed passive resistor temperature compensation technique exhibits less temperature drift and is expected to be highly applicable for pressure measurements in harsh environments with large temperature variations.

  15. Passive Resistor Temperature Compensation for a High-Temperature Piezoresistive Pressure Sensor

    PubMed Central

    Yao, Zong; Liang, Ting; Jia, Pinggang; Hong, Yingping; Qi, Lei; Lei, Cheng; Zhang, Bin; Li, Wangwang; Zhang, Diya; Xiong, Jijun

    2016-01-01

    The main limitation of high-temperature piezoresistive pressure sensors is the variation of output voltage with operating temperature, which seriously reduces their measurement accuracy. This paper presents a passive resistor temperature compensation technique whose parameters are calculated using differential equations. Unlike traditional experiential arithmetic, the differential equations are independent of the parameter deviation among the piezoresistors of the microelectromechanical pressure sensor and the residual stress caused by the fabrication process or a mismatch in the thermal expansion coefficients. The differential equations are solved using calibration data from uncompensated high-temperature piezoresistive pressure sensors. Tests conducted on the calibrated equipment at various temperatures and pressures show that the passive resistor temperature compensation produces a remarkable effect. Additionally, a high-temperature signal-conditioning circuit is used to improve the output sensitivity of the sensor, which can be reduced by the temperature compensation. Compared to traditional experiential arithmetic, the proposed passive resistor temperature compensation technique exhibits less temperature drift and is expected to be highly applicable for pressure measurements in harsh environments with large temperature variations. PMID:27455271

  16. Tympanic thermometer performance validation by use of a body-temperature fixed point blackbody

    NASA Astrophysics Data System (ADS)

    Machin, Graham; Simpson, Robert

    2003-04-01

    The use of infrared tympanic thermometers within the medical community (and more generically in the public domain) has recently grown rapidly, displacing more traditional forms of thermometry such as mercury-in-glass. Besides the obvious health concerns over mercury the increase in the use of tympanic thermometers is related to a number of factors such as their speed and relatively non-invasive method of operation. The calibration and testing of such devices is covered by a number of international standards (ASTM1, prEN2, JIS3) which specify the design of calibration blackbodies. However these calibration sources are impractical for day-to-day in-situ validation purposes. In addition several studies (e.g. Modell et al4, Craig et al5) have thrown doubt on the accuracy of tympanic thermometers in clinical use. With this in mind the NPL is developing a practical, portable and robust primary reference fixed point source for tympanic thermometer validation. The aim of this simple device is to give the clinician a rapid way of validating the performance of their tympanic thermometer, enabling the detection of mal-functioning thermometers and giving confidence in the measurement to the clinician (and patient!) at point of use. The reference fixed point operates at a temperature of 36.3 °C (97.3 °F) with a repeatability of approximately +/- 20 mK. The fixed-point design has taken into consideration the optical characteristics of tympanic thermometers enabling wide-angled field of view devices to be successfully tested. The overall uncertainty of the device is estimated to be is less than 0.1°C. The paper gives a description of the fixed point, its design and construction as well as the results to date of validation tests.

  17. Pollutant deposition via dew in urban and rural environment, Cracow, Poland

    NASA Astrophysics Data System (ADS)

    Muskała, Piotr; Sobik, Mieczysław; Błaś, Marek; Polkowska, Żaneta; Bokwa, Anita

    2015-01-01

    This study is a comparative analysis of dew in rural and urban environment. Dew samples were collected between May and October, 2009 in two reference stations in southern Poland: Cracow and Gaik-Brzezowa. The investigation included comparison of volume and chemistry of the collected samples. Due to its formation mechanisms, dew is a good indicator of air pollution. Following parameters were analyzed in 159 collected samples: pH, electric conductivity, concentration of formaldehyde and phenols, concentration of NH4+, Ca2 +, K+, Na+, and Mg2 + cations and NO2-, NO3-, SO42 -, Cl-, F-, and PO43 - anions. The frequency of dew was approximately the same, both in urban and rural conditions reaching 43% of the measurement period. Dew intensity, expressed by volume, was on average two times larger in rural environment than in urban conditions. Urban landuse was recognized as the main factor reducing dew intensity in the urban station in comparison to the rural. Furthermore, the intensity of dew depended on synoptic scale air circulation at both measurement sites. As expected, samples collected in Cracow were much more polluted than the ones from Gaik-Brzezowa. The average TIC (Total Ionic Content) parameter was approximately 50% higher at the urban station. The pH in the rural station was more acidic. NO3- anions and Ca2 + cations were predominant in both measurement sites, however the participation of Ca2 + in Cracow was higher. NO3- indicates pollutions emitted by transport and industrial sources. The concentration of the analytes in both stations, as the volume, depended on air circulation direction. For Gaik-Brzezowa the highest TIC was observed mainly within southern circulation, while for Cracow the highest TIC was noted within both northern and southern. In general the rural station represented background pollution for the whole region and the pollution in Cracow was more dependent on local urban sources as transport or industry.

  18. Tympanic temperature versus temporal temperature in patients with pyrexia and chills

    PubMed Central

    Yang, Wen-Chieh; Kuo, Huang-Tsung; Lin, Ching-Hsiao; Wu, Kang-Hsi; Chang, Yu-Jun; Chen, Chun-Yu; Wu, Han-Ping

    2016-01-01

    Abstract Accurate body temperature (BT) measurement is critical for immediate and correct estimation of core BT; measurement of changes in BT can provide physicians the initial information for selecting appropriate diagnostic approach and may prevent unnecessary diagnostic investigation. This study aimed to assess differences in tympanic and temporal temperatures among patients with fever in different conditions, especially in those with and without chills. This prospective study included patients from the emergency department between 2011 and 2012. All temperature measurements were obtained using tympanic thermometers and infrared skin thermometers. Differences in tympanic and temporal temperatures were analyzed according to 6 age groups, 5 ambient temperature groups, and 6 tympanic and temporal temperature subgroups. General linear model analysis and receiver operating characteristic curve analysis were used to estimate the differences in mean tympanic and temporal temperatures. Of the 710 patients enrolled, 246 had tympanic temperature more than 38.0°C, including 46 with chills (18.7%). Fourteen patients (3.0%) had chills and tympanic temperature less than 38°C. In the tympanic temperature subgroup of 39.0 to less than 39.5°C, approximately one-third of the patients had chills (32.3%). In the tympanic temperature subgroup of 38.0 to less than 39.0°C, the tympanic temperature was 0.4°C higher than the temporal temperature in patients without chills and 0.9°C higher in patients with chills. In the tympanic temperature subgroup of 39.0°C or more, tympanic temperature was 0.7°C higher than temporal temperature in patients without chills and 0.8°C higher in patients with chills. Temporal thermometer is more reliable in the age group of less than 1 year and 18 to less than 65 years. When the patients show tympanic temperature range of 38.0 to less than 39.0°C, 0.4°C should be added for patients without chills and 0.9°C for patients with chills to obtain

  19. Temperature data analysis for 22 patients with advanced cervical carcinoma treated in Rotterdam using radiotherapy, hyperthermia and chemotherapy: a reference point is needed.

    PubMed

    Fatehi, D; van der Zee, J; van der Wal, E; Van Wieringen, W N; Van Rhoon, G C

    2006-06-01

    .8 degrees Celsius. The average bladder and rectum all lumen T50 was 40.6 +/- 0.7 degrees Celsius and 40.5 +/- 0.6, respectively. When the analysis was restricted to the deepest 5 cm of the vagina lumen, the average T50 was 39.8 +/- 0.9 degrees Celsius. Good correlation exists between the various temperature indices like T20, T50 and T90, for all lumen measurements in bladder, vagina and rectum. No correlation was found between temperature indices and treatment number. For the complete patient population, no relationship was found between T50 and net integrated RF-power applied. In an explorative analysis on individual patients a positive correlation coefficient or trend was found in 14 patients between normalized net integrated RF-power and vagina T50. Average all lumen T50 for bladder, vagina and rectum differ less than 1 degrees Celsius, indicating that a large volume was heated relatively homogeneously. The vagina T50 value depends on how many measurement points are included for the analysis. In this group of patients the vagina T50 of the first treatment is not a good measure to discriminate between patients with 'heatable' and 'non-heatable' tumours. In order to compare temperature data reported by different institutes dealing with the same group of patients, one needs a strict and clear agreement on which temperature measurements or reference point(s) that should be included in the analysis.

  20. Singular temperature dependence of the equation of state of superconductors with spin–orbit interaction in the low-temperature region

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ovchinnikov, Yu. N., E-mail: ovc@itp.ac.ru

    The equation of state is investigated for a thin superconducting film in a longitudinal magnetic field and with strong spin-orbit interaction at the critical point. As a first step, the state with the maximal value of the magnetic field for a given value of spin–orbit interaction at T = 0 is chosen. This state is investigated in the low-temperature region. The temperature contribution to the equation of state is weakly singular.