Sample records for unreamed tibial nailing

  1. [Disruption of the arteria nutricia tibiae by reamed and unreamed intramedullary nailing. Study of the vascular architecture of the human tibial intramedullary cavity].

    PubMed

    Paar, O; mon O'Dey, D; Magin, M N; Prescher, A

    2000-01-01

    By reason of the pseudarthrotic healing of fractures due to vascular complications after reamed and unreamed intramedullary nailing, the intraosseous course and branching of the tibial nutrient artery and its impairment by nailing procedures needs an actual analysis. The nutrient vessel of 24 tibiae taken from fresh corpses were prepared by injection of Technovit and lead oxide. After this procedure the medullary cavities of 12 bones were opened by a frontal cut. These specimens were subjected to routine maceration. The other 12 tibiae were naed with the unreamed (6) and the reamed nailing (6) techniques. X-rays were also taken routinely. After penetration of the tibial compact bone the main trunk of the nutrient vessel runs through a perforated osseous tunnel (pars tecta arteriae nutriciae tibiae). At its end the vessel divides into a descending branch (obligate) and two ascending branches (facultative). The descending branch lies near to the centromedial region of the medullary cavity which is termed as the pars liberal arteriae nutriciae tibiae. All branches pass through supporting horizontal osseous lamellas. Due to this topography the reamed nailing technique destroyed the nutrient vessel completely in all specimens. In contrast to this observation the unreamed nailing destroyed the vessel completely only in 1 (16.7%) and partially in 3 (50%) bones; 2 (33.3%) specimens exhibited no destruction of the vessel. The unreamed as well as the reamed nailing technique can destroy the intramedullary course of the tibial nutrient artery. Fractures as well as displacement osteotomies or corticotomies are able to diminish the medullary blood supply seriously, if they are localised within the area of the tactic an of the tibial nutrient artery.

  2. Are there any advantages in using a distal aiming device for tibial nailing? Comparing the Centro Nailing System with the Unreamed Tibia Nail.

    PubMed

    Veen, Egbert J D; Ettema, Harmen B; Zuurmond, Rutger G; Mostert, Adriaan K

    2011-10-01

    The distal locking of an intramedullary tibial nail can be challenging and time consuming when performed freehand. This study was conducted to evaluate if a distal aiming device would reduce surgical time. A case-controlled study was performed between 2007 and 2009 with 30 patients receiving a reamed tibial nail (Centronail) with the use of a distal aiming device and 30 patients who were treated with an Unreamed Tibia Nail (UTN), with freehand distal locking, in the same period. The primary outcome in this study was operative time. Secondary outcomes were the need for fluoroscopy, time to consolidation and complications. Operation time was longer in the Centronail group compared with the UTN group (126 min vs. 96 min, p=0.000). Use of fluoroscopy for distal locking was needed in half of the cases (n=16) using a distal aiming device. No differences were found regarding time to consolidation, time to removal of the nail and complications. The use of an aiming device for distal locking of a tibia nail lengthens operation time rather than reducing it. Fluoroscopy was still needed in about half of the cases. No difference was seen in clinical outcomes. The use of a distal aiming device to lock a tibial nail appears to have no benefit. Copyright © 2011 Elsevier Ltd. All rights reserved.

  3. Segmental transport after unreamed intramedullary nailing. Preliminary report of a "Monorail" system.

    PubMed

    Raschke, M J; Mann, J W; Oedekoven, G; Claudi, B F

    1992-09-01

    The Ilizarov method of segmental bone transport has been shown to be an alternative to more conventional treatments of posttraumatic bony defects. After extensive clinical experience with the unreamed tibial nail in open fractures up to Grade IIIb, a new monorail fixation system for callus distraction and segmental bone transport was devised. This Monorail system is composed of an unreamed intramedullary (IM) nail and a unilateral AO distraction device. The new fixation method and the preliminary clinical experience are reported here. Four patients who previously sustained Grades II-IIIb open tibial fractures had an average bony defect of 9 cm. Two patients had previous bony infections. All patients had had serial debridements and myocutaneous flaps were required in three patients. An unreamed IM nail was inserted, and the transport device was applied. After an osteotomy, segmental transport was carried out until docking was achieved. The external fixator was removed after interlocking of the transported segment. The mean duration of external fixation was 17.9 days/cm and the mean period until roentgenographic consolidation of the distraction and nonunion site was 41.2 days/cm. There were two pin-tract infections but no IM infections. One nail broke after osseous consolidation of the regenerate at the distal interlocking site and required exchange. The goal of transport was achieved in all cases without angular or rotational deformity or length discrepancy. There were no neurovascular injuries.

  4. Pulmonary fat embolism after reamed and unreamed nailing of femoral fractures.

    PubMed

    Högel, F; Gerlach, U V; Südkamp, N P; Müller, C A

    2010-12-01

    To determine whether reamed or unreamed intramedullary nailing of femoral fractures results in higher incidence of pulmonary fat embolism, three different methods of intramedullary nailing were compared in sheep. To analyze the presence of bone marrow fat embolism in pulmonary arteries, histological evaluation was undertaken using a quantitative computer-assisted measurement system. In this experimental model of 27 female Swiss alpine sheep, an osteotomy of the proximal femur was conducted in each animal. Then, the animals were divided into three groups according to the method of treatment: two different reamed intramedullary nailing techniques and an unreamed nailing technique were used. In the first group "ER" (experimental reamer; n=9), the nail was inserted after reaming with an experimental reamer; in the second group "CR" (conventional reamer; n=7), the intramedullary nail was inserted after reaming with the conventional AO-reamer. In the third group "UN" (unreamed; n=8) unreamed nailing was performed. During the operation procedure intramedullary pressure was measured in the distal fragment. After sacrificing the animals, quantitative histological analyses of bone marrow fat embolism in pulmonary arteries were done using osmium tetroxide fixation and staining of the fat. The measurement of intramedullary pressure showed significantly lower values for reamed nailing than for the unreamed technique. The quantitative histological evaluation of lung vessels concerning bone marrow fat embolism revealed a statistically significant difference between reamed and unreamed insertion of the nail: 7.77%±6.93 (ER) and 6.66%±5.61 (CR) vs. 16.25%±10.05 (UN) (p<0.05) of the assessed lung vessels were filled with fat emboli. However, no difference was found between the traditional and experimental reamer. Intramedullary nailing after reaming is a safe procedure with low systemic embolisation when compared to the unreamed insertion of the nail. Copyright © 2010 Elsevier

  5. Minimizing the complications of intramedullary nailing for distal third tibial shaft and metaphyseal fractures

    PubMed Central

    Yaligod, Vishwanath; Rudrappa, Girish H.; Nagendra, Srinivas; Shivanna, Umesh M.

    2013-01-01

    Background The complications of intramedullary nailing of distal third tibial shaft and metaphyseal fractures have a direct impact on ankle and hind foot function. Methods We retrospectively evaluated 28 patients. Unreamed nail was negotiated across the well reduced fracture till subchondral bone and fixed with 2 to 3 distal locking screws in different planes. Results Fracture union rate was 85%. Three out of 28 patients had malalignment. Mean ankle, hindfoot functional score was 85. Conclusion Complications can be minimized by impacting the unreamed nail till the subchondral bone while maintaining the fracture well reduced and by using multiple distal locking screws in different planes. PMID:24719527

  6. Factors influencing interlocking screw failure in unreamed small diameter nails--a biomechanical study using a distal tibia fracture model.

    PubMed

    Weninger, Patrick; Schueller, Michael; Jamek, Michael; Stanzl-Tschegg, Stefanie; Redl, Heinz; Tschegg, Elmar K

    2009-05-01

    Unreamed tibia nails with small diameters are increasingly used for fracture fixation. However, little is known about the fatigue strength of proximal and distal interlocking screws in those nails. To date, no data are available reporting on mechanical differences of solid compared to cannulated tibial nails. The aim of this study was to assess the fatigue strength of proximal and distal interlocking screws of solid and cannulated small diameter tibia nails. We created a distal tibia fracture model (AO/OTA 43 A3) using 16 Sawbones. After fracture stabilization with one of four different nail types (Expert Tibial Nail, VersaNail, T2 Tibial Nailing System, Connex), mechanical testing was performed in three loading series (40,000 cycles each) with incremental loads. Timing and type of interlocking screw failure were assessed. Interlocking screw failure was observed significantly earlier (after a mean interval of 57,042 cycles) in cannulated tibial nails (VersaNail, T2) compared to solid nails (after a mean interval of 88,415 cycles; P < 0.001). Proximal interlocking screw failure was recorded if oblique screws were used proximally (VersaNail, T2, Connex). No distal interlocking screw failure was recorded in the Connex nail. Two- and three-part fractures of proximal or distal interlocking screws were observed in all specimen. Proximal and distal interlocking screw failure has to be considered in small diameter nails in case of delayed fracture healing. To support our results, further experimental studies and clinical series are necessary.

  7. [Current status of surgical technique for unreamed nailing of tibial shaft fractures with the UTN (unreamed tibia nail)].

    PubMed

    Krettek, C; Schandelmaier, P; Rudolf, J; Tscherne, H

    1994-11-01

    Nailing technique has changed in recent years in some important aspects which are not limited to the omitted reaming procedure. These changes concern patient positioning, reduction technique, the use of temporary stabilizers such as the 'Pinless', and determination of implant length and diameter. Approach and exposure techniques have been modified to new, less invasive procedures, in order to fulfill technical, functional and aesthetic requirements. Techniques and tricks have been developed for avoidance of fragment diastasis and axial and torsional malalignment. Finally, simple algorithms are described for the management of large bone defects, bilateral tibia shaft or ipsilateral femoral shaft fractures, number and location of locking bolts, the 'when and how' of patient mobilization and load bearing, and primary and secondary dynamization. These algorithms, techniques and procedures were developed in a series of 152 tibia shafts, which were stabilized with the AO unreamed tibia nail (UTN) in a prospective study between March 1989 and June 1994. Of these, 75 cases with a mean follow-up of 19.4 +/- 6.3 (range 11-37) months after trauma were reviewed. Fractures were classified according to Müller (1990): 14 type A, 37 type B and 24 type C. Closed soft tissue damage was categorized according to our classification: C0/1, n = 5; C2, n = 12; C3, n = 9 (Tscherne 1982). Among 49 open fractures 8 were OI, 18 OII, 10 OIIIA and 13 OIIIB (Gustilo 1976). The main minor intraoperative complication was drill bit breakage (n = 10), most frequently at the proximal locking holes. The main postoperative complication was breakage of locking bolts (n = 16), mainly between weeks 6 and 20. Minor secondary reinterventions were, in most cases, secondary dynamization under local anaesthesia. Major reintervention were: soft tissue reconstructions (n = 5), isolated cancellous bone graft (n = 6), and change of treatment (n = 12). There were nine changes to a reamed nail, two changes, in very

  8. Reamed versus unreamed intramedullary nailing for the treatment of femoral fractures

    PubMed Central

    Li, A-Bing; Zhang, Wei-Jiang; Guo, Wei-Jun; Wang, Xin-Hua; Jin, Hai-Ming; Zhao, You-Ming

    2016-01-01

    Abstract Background and objective: Intramedullary nailing is commonly used for treating femoral shaft fractures, one of the most common long bone fractures in adults. The reamed intramedullary nail is considered the standard implant for femoral fractures. This meta-analysis was performed to verify the superiority of reamed intramedullary nailing over unreamed intramedullary nailing in fractures of the femoral shaft in adults. Subgroup analysis of implant failure and secondary procedure was also performed. Methods: Electronic literature databases were used to identify relevant publications and included MEDLINE (Ovid interface), EMBASE (Ovid interface), and the Cochrane Central Register of Controlled Trials (CENTRAL; Wiley Online Library). The versions available on January 30, 2016, were utilized. Only human studies, which were designed as randomized controlled clinical trials, were included. Two authors independently evaluated the quality of original research publications and extracted data from the studies that met the criteria. Results: Around 8 randomized controlled trials involving 1078 patients were included. Reamed intramedullary nailing was associated with shorter time to consolidation of the fracture (SMD = –0.62, 95% CI = –0.89 to –0.35, P < 0.00001), lower secondary procedure rate (OR = 0.25, 95% CI 0.10–0.62, P = 0.003), lower nonunion rate (OR = 0.14, 95% CI = 0.05–0.40, P < 0.01), and lower delayed-union rate (OR = 0.19, 95% CI = 0.07–0.49, P < 0.01) compared to unreamed intramedullary nailing. The 2 groups showed no significant differences in risk of implant failure (OR = 0.50, 95% CI 0.14–1.74, P = 0.27), mortality risk (OR = 0.94, 95% CI 0.19–4.68, P = 0.94), risk of acute respiratory distress syndrome (ARDS; OR = 1.55, 95% CI 0.36–6.57, P = 0.55), or blood loss (SMD = 0.57, 95% CI = –0.22 to 1.36, P = 0.15). Conclusion: Reamed intramedullary nailing

  9. [The monorail system--bone segment transport over unreamed interlocking nails].

    PubMed

    Oedekoven, G; Jansen, D; Raschke, M; Claudi, B F

    1996-11-01

    A treatment protocol is demonstrated, consisting of an osteotomy, either proximal or distal, of the bone defect with subsequent segmental transport via an anteromedially (tibia) or laterally (femur) mounted AO external fixation over an unreamed interlocking nail (monorail system). Twenty patients were treated by this method with indications as follows: 13 had a segmental bone defect of the tibia, 3 of the femur. Three patients showed post-traumatic and postinfectious leg-length discrepancies and one was treated for hypertrophic non-union of the femur. Defect distance varied between 5 and 18.5 cm and average time for transport was 19,42 days/ cm for the tibial shaft, 15,93 days/cm for the femur. Two patients developed deep infection, which required change of treatment, removing the monorail system and application of an Ilizarov apparatus. Despite complications using the monorail system, all patients healed and no amputations were required. The monorail system can be used as an alternative to the Ilizarov method under certain criteria of patient selection; these criteria are shown by an algorithm for segmental bone defects without infection, respecting the soft-tissue status with or without neurovascular compromise.

  10. Dynamic osteosynthesis by modified Kuntscher nail for the treatment of tibial diaphyseal fractures.

    PubMed

    Gadegone, Wasudeo M; Salphale, Yogesh S

    2009-04-01

    We evaluated a series of diaphyseal fractures of the tibia using low-cost, Indian-made modified Kuntscher nail (Daga nail) with the provision of distal locking screw for the management of the tibial diaphyseal fractures. One hundred and fifty one consecutive patients with diaphyseal fractures of tibia with 151 fractures who were treated by Daga nail were enrolled. One of the patients who had died because of cancer, and the two patients who were lost to follow-up at 3 months were excluded from the study.Therefore data of 148 patients with one hundred and fortyeight fractures is described. One hundred twenty closed fractures, 20 open Grade I fractures, and eight open Grade II fractures as per Gustilo and Anderson classification were included in this study. One hundred fourteen men and 34 women, with a mean age of 38.4 years, were studied. The result were analysed for Surgical time, duration of hospitalisation, union time, union rate, complication rate, functional recovery and crutch walking time. The fractures were followed at least until the time of solid union. The follow-up period averaged 15 months (range, 6-26 months). Union occurred in 140 cases (94.6%). The mean time to union was 13 weeks for closed fractures,17.8 weeks for Grade I open fractures, and 21.6 weeks for Grade II open fractures. Compartment syndrome occurred in two patients. Superficial infection occurred in five cases of Grade I and II compound fractures. Three closed fractures and one case of Grade I compound fracture required bone grafting for delayed union. Two cases of Grade II compound fracture with nonunion required revision surgery and bone grafting. Twelve cases resulted in acceptable malalignment due to operative technical error. In four cases, the distal screw breakage was seen, but none of these complications interfered with fracture healing. Recovery of joint motion was essentially normal in those patients without knee or ankle injury. Unreamed distally locked dynamic tibial nailing

  11. Which Surgical Treatment for Open Tibial Shaft Fractures Results in the Fewest Reoperations? A Network Meta-analysis.

    PubMed

    Foote, Clary J; Guyatt, Gordon H; Vignesh, K Nithin; Mundi, Raman; Chaudhry, Harman; Heels-Ansdell, Diane; Thabane, Lehana; Tornetta, Paul; Bhandari, Mohit

    2015-07-01

    Open tibial shaft fractures are one of the most devastating orthopaedic injuries. Surgical treatment options include reamed or unreamed nailing, plating, Ender nails, Ilizarov fixation, and external fixation. Using a network meta-analysis allows comparison and facilitates pooling of a diverse population of randomized trials across these approaches in ways that a traditional meta-analysis does not. Our aim was to perform a network meta-analysis using evidence from randomized trials on the relative effect of alternative approaches on the risk of unplanned reoperation after open fractures of the tibial diaphysis. Our secondary study endpoints included malunion, deep infection, and superficial infection. A network meta-analysis allows for simultaneous consideration of the relative effectiveness of multiple treatment alternatives. To do this on the subject of surgical treatments for open tibial fractures, we began with systematic searches of databases (including EMBASE and MEDLINE) and performed hand searches of orthopaedic journals, bibliographies, abstracts from orthopaedic conferences, and orthopaedic textbooks, for all relevant material published between 1980 and 2013. Two authors independently screened abstracts and manuscripts and extracted the data, three evaluated the risk of bias in individual studies, and two applied Grading of Recommendation Assessment, Development and Evaluation (GRADE) criteria to bodies of evidence. We included all randomized and quasirandomized trials comparing two (or more) surgical treatment options for open tibial shaft fractures in predominantly (ie, > 80%) adult patients. We calculated pooled estimates for all direct comparisons and conducted a network meta-analysis combining direct and indirect evidence for all 15 comparisons between six stabilization strategies. Fourteen trials published between 1989 and November 2011 met our inclusion criteria; the trials comprised a total of 1279 patients surgically treated for open tibial

  12. Tibial lengthening over humeral and tibial intramedullary nails in patients with sequelae of poliomyelitis: a comparative study.

    PubMed

    Chen, Daoyun; Chen, Jianmin; Jiang, Yao; Liu, Fanggang

    2011-06-01

    Leg discrepancy is common after poliomyelitis. Tibial lengthening is an effective way to solve this problem. It is believed lengthening over a tibial intramedullary nail can provide a more comfortable lengthening process than by the conventional technique. However, patients with sequelae of poliomyelitis typically have narrow intramedullary canals allowing limited space for inserting a tibial intramedullary nail and Kirschner wires. To overcome this problem, we tried using humeral nails instead of tibial nails in the lengthening procedure. In this study, we used humeral nails in 20 tibial lengthening procedures and compared the results with another group of patients who were treated with tibial lengthening over tibial intramedullary nails. The mean consolidation index, percentage of increase and external fixation index did not show significant differences between the two groups. However, less blood loss and shorter operating time were noted in the humeral nail group. More patients encountered difficulty with the inserted intramedullary nail in the tibial nail group procedure. The complications did not show a statistically significant difference between the two techniques on follow-up. In conclusion, we found the humeral nail lengthening technique was more suitable in leg discrepancy patients with sequelae of poliomyelitis.

  13. Fatigue strength of common tibial intramedullary nail distal locking screws

    PubMed Central

    Griffin, Lanny V; Harris, Robert M; Zubak, Joseph J

    2009-01-01

    Background Premature failure of either the nail and/or locking screws with unstable fracture patterns may lead to angulation, shortening, malunion, and IM nail migration. Up to thirty percent of all unreamed nail locking screws can break after initial weight bearing is allowed at 8–10 weeks if union has not occurred. The primary problem this presents is hardware removal during revision surgery. The purposes of our study was to evaluate the relative fatigue resistance of distal locking screws and bolts from representative manufacturers of tibial IM nail systems, and develop a relative risk assessment of screws and materials used. Evaluations included quantitative and qualitative measures of the relative performance of these screws. Methods Fatigue tests were conducted to simulate a comminuted fracture that was treated by IM nailing assuming that all load was carried by the screws. Each screw type was tested ten times in a single screw configuration. One screw type was tested an additional ten times in a two-screw parallel configuration. Fatigue tests were performed using a servohydraulic materials testing system and custom fixturing that simulated screws placed in the distal region of an appropriately sized tibial IM nail. Fatigue loads were estimated based on a seventy-five kilogram individual at full weight bearing. The test duration was one million cycles (roughly one year), or screw fracture, whichever occurred first. Failure analysis of a representative sample of titanium alloy and stainless steel screws included scanning electron microscopy (SEM) and quantitative metallography. Results The average fatigue life of a single screw with a diameter of 4.0 mm was 1200 cycles, which would correspond roughly to half a day of full weight bearing. Single screws with a diameter of 4.5 mm or larger have approximately a 50 percent probability of withstanding a week of weight bearing, whereas a single 5.0 mm diameter screw has greater than 90 percent probability of

  14. Prognostic Factors for Predicting Outcomes After Intramedullary Nailing of the Tibia

    PubMed Central

    Schemitsch, Emil H.; Bhandari, Mohit; Guyatt, Gordon; Sanders, David W.; Swiontkowski, Marc; Tornetta, Paul; Walter, Stephen D.; Zdero, Rad; Goslings, J.C.; Teague, David; Jeray, Kyle; McKee, Michael D.; Schemitsch, Emil H.; Bhandari, Mohit; Guyatt, Gordon; Sanders, David W.; Swiontkowski, Marc; Tornetta, Paul; Walter, Stephen D.; Zdero, Rad; Goslings, J.C.; Teague, David; Jeray, Kyle; McKee, Michael D.

    2012-01-01

    Background: Prediction of negative postoperative outcomes after long-bone fracture treatment may help to optimize patient care. We recently completed the Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT), a large, multicenter trial of reamed and unreamed intramedullary nailing of tibial shaft fractures in 1226 patients. Using the SPRINT data, we conducted an investigation of baseline and surgical factors to determine any associations with an increased risk of adverse events within one year of intramedullary nailing. Methods: Using multivariable logistic regression analysis, we investigated fifteen baseline and surgical factors for any associations with an increased risk of negative outcomes. Results: There was an increased risk of negative events in patients with a high-energy mechanism of injury (odds ratio [OR] = 1.57; 95% confidence interval [CI], 1.05 to 2.35), a stainless steel compared with a titanium nail (OR = 1.52; 95% CI, 1.10 to 2.13), a fracture gap (OR = 2.40; 95% CI, 1.47 to 3.94), and full weight-bearing status after surgery (OR = 1.63; 95% CI, 1.00 to 2.64). There was no increased risk with the use of nonsteroidal anti-inflammatory agents, late or early time to surgery, or smoking status. Open fractures had a higher risk of events among patients treated with reamed nailing (OR = 3.26; 95% CI, 2.01 to 5.28) but not in patients treated with unreamed nailing (OR = 1.50; 95% CI, 0.92 to 2.47). Patients with open fractures who had wound management either without any additional procedures or with delayed primary closure had a decreased risk of events compared with patients who required subsequent, more complex reconstruction (OR = 0.18 [95% CI, 0.09 to 0.35] and 0.29 [95% CI, 0.14 to 0.62], respectively). Conclusions: We identified several baseline fracture and surgical characteristics that may increase the risk of adverse events in patients with tibial shaft fractures. Surgeons should consider the

  15. Influence of medial parapatellar nail insertion on alignment in proximal tibia fractures--special consideration of the fracture level.

    PubMed

    Weninger, Patrick; Tschabitscher, Manfred; Traxler, Hannes; Pfafl, Veronika; Hertz, Harald

    2010-04-01

    Although a lateral starting point for tibial nailing is recommended to avoid valgus misalignment, higher rates of intra-articular damage were described compared with a medial parapatellar approach. The aim of this anatomic study was to evaluate the fracture level allowing for a safe medial nail entry point without misalignment or dislocation of fragments. Thirty-two fresh-frozen cadaver lower extremities were used to create 1-cm osteotomies at four different levels (n = 8) from 2 cm to 8 cm below the tibial tuberosity. Nine-millimeter unreamed solid titanium tibial nails (Connex, I.T.S. Spectromed, Lassnitzhohe, Austria) were inserted from a medial parapatellar incision. Misalignment (degree) and dislocation of the distal fragment were measured in the frontal and sagittal plane. A medial parapatellar approach for tibial nail insertion mainly caused valgus and anterior bow misalignment and ventral and medial fragment displacement. Mean misalignment and fragment displacement did not exceed 0.5 degree if the osteotomy was performed 8 cm to 9 cm below the tibial tuberosity. According to the results of this study, a medial parapatellar approach can be performed without misalignment and fragment dislocation in proximal tibia fractures extending 8 cm or more below the tibial tuberosity.

  16. Tibial lengthening over intramedullary nails

    PubMed Central

    Burghardt, R. D.; Manzotti, A.; Bhave, A.; Paley, D.

    2016-01-01

    Objectives The purpose of this study was to compare the results and complications of tibial lengthening over an intramedullary nail with treatment using the traditional Ilizarov method. Methods In this matched case study, 16 adult patients underwent 19 tibial lengthening over nails (LON) procedures. For the matched case group, 17 patients who underwent 19 Ilizarov tibial lengthenings were retrospectively matched to the LON group. Results The mean external fixation time for the LON group was 2.6 months and for the matched case group was 7.6 months. The mean lengthening amounts for the LON and the matched case groups were 5.2 cm and 4.9 cm, respectively. The radiographic consolidation time in the LON group was 6.6 months and in the matched case group 7.6 months. Using a clinical and radiographic outcome score that was designed for this study, the outcome was determined to be excellent in 17 and good in two patients for the LON group. The outcome was excellent in 14 and good in five patients in the matched case group. The LON group had increased blood loss and increased cost. The LON group had four deep infections; the matched case group did not have any deep infections. Conclusions The outcomes in the LON group were comparable with the outcomes in the matched case group. The LON group had a shorter external fixation time but experienced increased blood loss, increased cost, and four cases of deep infection. The advantage of reducing external fixation treatment time may outweigh these disadvantages in patients who have a healthy soft-tissue envelope. Cite this article: J. E. Herzenberg. Tibial lengthening over intramedullary nails: A matched case comparison with Ilizarov tibial lengthening. Bone Joint Res 2016;5:1–10. doi: 10.1302/2046-3758.51.2000577 PMID:26764351

  17. The effect of retained intramedullary nails on tibial bone mineral density.

    PubMed

    Allen, J C; Lindsey, R W; Hipp, J A; Gugala, Z; Rianon, N; LeBlanc, A

    2008-07-01

    Intramedullary nailing has become a standard treatment for adult tibial shaft fractures. Retained intramedullary nails have been associated with stress shielding, although their long-term effect on decreasing tibial bone mineral density is currently unclear. The purpose of this study was to determine if retained tibial intramedullary nails decrease tibial mineral density in patients with successfully treated fractures. Patients treated with statically locked intramedullary nails for isolated, unilateral tibia shaft fractures were studied. Inclusion required that fracture had healed radiographically and that the patient returned to the pre-injury activity level. Data on patient demographic, fracture type, surgical technique, implant, and post-operative functional status were tabulated. Dual energy X-ray absorptiometry was used to measure bone mineral density in selected regions of the affected tibia and the contralateral intact tibia. Image reconstruction software was employed to ensure symmetry of the studied regions. Twenty patients (mean age 43; range 22-77 years) were studied at a mean of 29 months (range 5-60 months) following intramedullary nailing. There was statistically significant reduction of mean bone mineral density in tibiae with retained intramedullary nails (1.02 g/cm(2) versus 1.06 g/cm(2); P=0.04). A significantly greater decrease in bone mineral density was detected in the reamed versus non-reamed tibiae (-7% versus +6%, respectively; P<0.05). The present study demonstrates a small, but statistically significant overall bone mineral density decrease in healed tibiae with retained nails. Intramedullary reaming appears to be a factor potentiating the reduction of tibia bone mineral density in long-term nail retention.

  18. Ideal tibial intramedullary nail insertion point varies with tibial rotation.

    PubMed

    Walker, Richard M; Zdero, Rad; McKee, Michael D; Waddell, James P; Schemitsch, Emil H

    2011-12-01

    The aim of the study was to investigate how superior entry point varies with tibial rotation and to identify landmarks that can be used to identify suitable radiographs for successful intramedullary nail insertion. The proximal tibia and knee were imaged for 12 cadaveric limbs undergoing 5° increments of internal and external rotation. Medial and lateral arthrotomies were performed, the ideal superior entry point was identified, and a 2-mm Kirschner wire inserted. A second Kirschner wire was sequentially placed at the 5-mm and then the 10-mm position, both medial and lateral to the initial Kirschner wire. Radiographs of the knee were obtained for all increments. The changing position of the ideal nail insertion point was recorded. A 30° arc (range, 25°-40°) provided a suitable anteroposterior radiograph. On the neutral anteroposterior radiograph, the Kirschner wire was 54% ± 1.5% (range, 51-56%) from the medial edge of the tibial plateau. For every 5° of rotation, the Kirschner wire moved 3% of the plateau width. During external rotation, a misleading medial entry point was obtained. A fibular bisector line correlated with an entry point that was ideal or up to 5 mm lateral to this but never medial. The film that best showed the fibular bisector line was between 0° and 10° of internal rotation of the tibia. The fibula head bisector line can be used to avoid choosing external rotation views and, thus, avoid medial insertion points. The current results may help the surgeon prevent malalignment during intramedullary nailing in proximal tibial fractures.

  19. Outcome of intramedullary interlocking SIGN nail in tibial diaphyseal fracture.

    PubMed

    Khan, Irfanullah; Javed, Shahzad; Khan, Gauhar Nawaz; Aziz, Amer

    2013-03-01

    To determine the outcome of intramedullary interlocking surgical implant generation network (SIGN) nail in diaphyseal tibial fractures in terms of union and failure of implant (breakage of nail or interlocking screws). Case series. Orthopaedics and Spinal Surgery, Ghurki Trust Teaching Hospital, Lahore Medical and Dental College, Lahore, from September 2008 to August 2009. Fifty patients aged 14 - 60 years, of either gender were included, who had closed and Gustilo type I and II open fractures reported in 2 weeks, whose closed reduction was not possible or was unsatisfactory and fracture was located 7 cm below knee joint to 7 cm above ankle joint. Fractures previously treated with external fixator, infected fractures and unfit patients were excluded. All fractures were fixed with intramedullary interlocking SIGN nail and were followed clinically and radiographically for union and for any implant failure. Forty one (88%) patients had united fracture within 6 months, 5 (10%) patients had delayed union while 4 (8%) patients had non-union. Mean duration for achieving union was 163 + 30.6 days. Interlocking screws were broken in 2 patients while no nail was broken in any patient. Intramedullary interlocking nailing is an effective measure in treating closed and grade I and II open tibial fractures. It provides a high rate of union less complications and early return to function.

  20. Distal tibial fractures and non-unions treated with shortened intramedullary nail.

    PubMed

    Megas, P; Zouboulis, P; Papadopoulos, A X; Karageorgos, A; Lambiris, E

    2003-01-01

    We reviewed 18 patients, 14 with acute fractures and four with non-union of the distal tibia, treated between 1990 and 2001 with a shortened, reamed intramedullary nail. The mean follow-up was 38 (8-144) months. The fractures united at an average of 16 (12-18) weeks and the non-unions at 20 (12-30) weeks. Two patients required nail dynamization. No limb shortening nor material failures were seen. All patients returned to normal daily activities. Although technically demanding, intramedullary nailing for distal tibial fractures and non-unions with a shortened nail represents a safe and reliable method.

  1. [Comparison of LCP and locked intramedullary nailing fixation in treatment of tibial diaphysis fractures].

    PubMed

    Huang, Peng; Tang, Peifu; Yao, Qi

    2007-11-01

    To evaluate the treatment results of LCP and locked intramedullary nailing for tibial diaphysis fractures. From October 2003 to April 2006, 55 patients with tibial diaphysis fractures (58 fractures) were treated. Of them there were 39 males and 16 females with an average of 39 years years ( 14 to 62 years). The fractures were on the left side in 27 patients and on the right side in 31 patients (3 patients had bilateral involvement). Thirty-four fractures were treated by intramedullary nailing (intramedullary nailing group) and 24 fractures by LCP fixation (LCP group). The average disease course was 3 days (intramedullary nailing group) and 3.1 days (LCP group). The operation time, the range of motion of knee and ankle joints, fracture healing time, and complications were evaluated. The patients were followed up 8-26 months (13 months on average). The operation time was 84.0+/-9.2 min (intramedullary nailing group) and 69.0+/-8.4 min (LCP group); the average cost in hospital was yen 19,297.78 in the intramedullary nailing group and yen 14,116.55 in the LCP group respectively, showing significant differences (P < 0.05). The flexion and extension of knee joint was 139.0 +/- 3.7 degrees and 4.0 +/- 0.7 degrees in intramedullary nailing group and 149.0+/-4.2 degrees and 0+/-0.4 degrees in LCP group, showing no significant difference (P>0.05). The doral flexion and plantar flexion of ankle joint were 13.0+/-1.7 degrees and 41.0+/-2.6 degrees in intramedullary nailing group, and 10.0+/-1.4 degrees and 44.0+/-2.3 degrees in LCP group, showing no significant differences (P>0.05). The mean healing time was 3.3 months in intramedullary nailing group, and 3. 1 months in LCP group. Length discrepancy occurred in 1 case (2.5 cm), delayed union in 1 case and nailing end trouble in 3 cases in intramedullary nailing group; moreover rotation deformity occurred 1 case and anterior knee pain occurred in 6 cases (17.1%). One angulation and open fracture developed osteomyelitis in 1

  2. "Clothesline technique" for proximal tibial shaft fracture fixation using conventional intramedullary nail: a simple, useful, and inexpensive technique to prevent fracture malalignment.

    PubMed

    Belangero, William Dias; Santos Pires, Robinson Esteves; Livani, Bruno; Rossi, Felipe Lins; de Andrade, Andre Luis Lugnani

    2018-05-01

    Treatment of proximal tibial shaft fractures is always challenging. Despite the development of modern techniques, the literature still shows high complication rates, especially regarding proximal fragment malalignment. It is well known that knee position in flexion during tibial nailing is responsible for extension and valgus deformities of the proximal fragment. Unlike in tibial shaft fractures, nails do not reduce proximal tibial fractures due to the medullary canal width. This study aims to describe a simple, useful, and inexpensive technique to prevent valgus and extension deformities when treating proximal tibial fractures using conventional nails: the so-called clothesline technique.

  3. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report.

    PubMed

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients.

  4. Intramedullary nailing in the treatment of aseptic tibial nonunion.

    PubMed

    Megas, P; Panagiotopoulos, E; Skriviliotakis, S; Lambiris, E

    2001-04-01

    Fifty patients suffering from aseptic tibial nonunion underwent reamed intramedullary nailing (I.N.) and were retrospectively reviewed. Thirty-six patients were initially treated with external fixation, six with plate and screws, one with a static I.N., and seven with plaster of Paris. Eighteen of the fractures were initially open (A: 5, B: 6, and C: 7 according to the Gustilo classification). In 34 cases a closed procedure was performed, whereas in sixteen, an opening at the nonunion site was unavoidable either to remove metalwork or realign the fragments. Following failed external fixation, secondary I.N. was performed at least 10 days after removal of the device. Bone grafts from the iliac crest were used in three cases, and a fibular osteotomy was performed in 33. Patients were followed up for an average of 2.5 years after nailing, ranging from 10 months to 7 years. A solid union was achieved in all patients within a period of 6 months. One patient developed late infection, which settled after nail removal and one patient developed impending compartment syndrome which was detected on the first post-operative day and was treated with a fasciotomy. Transient peroneal nerve palsy occurred in one patient and this recovered in 3 months, whereas in nine patients a clinically acceptable deformity was noticed. In conclusion, we believe that reamed intramedullary nailing is a highly effective treatment for aseptic tibial nonunions. Early and late complications are rare and bone graft is rarely needed. The method allows early weight bearing even before solid union occurs, short hospitalisation time and early return to work without external support.

  5. Temporary Fixation Using a Long Femoral-tibial Nail to Treat a Displaced Medial Tibial Plateau Fracture in a 90-year-old Patient: A Case Report

    PubMed Central

    Batta, V; Sinha, S; Trompeter, A

    2017-01-01

    Introduction: Tibial plateau fractures are complex injuries in the elderly population. When traditional methods of fixation are not suitable, an alternative method needs to be chosen for a favorable outcome. We demonstrate a previously undescribed treatment for displaced tibial plateau fractures in the very elderly with poor soft-tissue integrity. Case Report: A 90-year-old woman suffered an open, Gustilo Grade IIIA, displaced fracture of the tibial plateau. An intramedullary knee arthrodesis, the femoral-tibial nail was used to temporarily stabilize her fracture. She was able to weight bear immediately postfixation. Conclusion: A long femoral-tibial nail allows favorable fracture and soft tissue healing, ease of nursing and immediate full weight-bearing. It shows good promise and should be considered as a management option when traditional methods are not applicable in select patients. PMID:29181350

  6. Technique tip: use of anterior cruciate ligament jig for hindfoot fusion by calcanio-talo-tibial nail.

    PubMed

    Haque, Syed; Sarkar, Jay

    2012-08-01

    The use of intramedullary nail fixation for tibio-talo-calcaneal fusion is gaining popularity. There is chance of failure of procedure following faulty operative technique specially alignment. The article describes a useful application of tibial tunnel jig in inserting the calcanio-talo-tibial guide wire. There is precision of few millimeters in the exit point of guide wire on talus. The authors believe that this helps in better positioning of nail and hence better alignment and better operative outcome.

  7. Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study.

    PubMed

    Mukherjee, Sagnik; Arambam, Mahendra Singh; Waikhom, Sanjib; Santosha; Masatwar, Pranav Vitthal; Maske, Rohan Gautam

    2017-04-01

    Tibial diaphyseal fractures are the commonest long bone fractures in adults, most commonly managed by intramedullary interlocking nailing. However, several meta-analysis show that locking plate osteosynthesis is equally effective in managing tibial diaphyseal fractures and are associated with less number of complications. To compare the results of fixation of tibial fractures following plating and nailing in terms of union, patient satisfaction and complications. A hospital based non randomized clinical trial was performed from September 2013 to August 2016 where closed or open diaphyseal or metaphyseo- diaphyseal fractures of the tibia (closed or open Gustilo Anderson type 1 through 3B) were included. Simple sequential allocation was used for allotting the patients to two groups, one for interlocking nailing and other for plating. The patients were followed up for clinical, radiographic and functional results. Forty patients with 41 involved limbs completed follow up for one year. The duration of surgery and average blood loss during surgery was 75.45±3.03 minutes and 165.00±5.31 ml respectively in case of nailing and 85.05±2.54 minutes and184.29±5.33 ml respectively in case of plating and their difference was statistically significant. In our study union was achieved in less than 20 weeks in 29 (70.8%) of the patients and 25-30 weeks in nine (22%) cases. The average time of union in our study was 19.55±0.69 weeks in case of interlocking nailing and 20.38±1.39 weeks in case of plating and there was no statistically significant difference between the two. However, there is statistically significant difference in the functional score in between the two groups in terms of Lower Extremity Functional Score (LEFS). Delayed union in one case of nailing and two cases of plating, valgus malunion in one case of nailing and joint stiffness in two cases each of nailing and plating were the major complications observed. There was no difference between the two modalities

  8. Interlocking Nailing Versus Plating in Tibial Shaft Fractures in Adults: A Comparative Study

    PubMed Central

    Arambam, Mahendra Singh; Waikhom, Sanjib; Santosha; Masatwar, Pranav Vitthal; Maske, Rohan Gautam

    2017-01-01

    Introduction Tibial diaphyseal fractures are the commonest long bone fractures in adults, most commonly managed by intramedullary interlocking nailing. However, several meta-analysis show that locking plate osteosynthesis is equally effective in managing tibial diaphyseal fractures and are associated with less number of complications. Aim To compare the results of fixation of tibial fractures following plating and nailing in terms of union, patient satisfaction and complications. Materials and Methods A hospital based non randomized clinical trial was performed from September 2013 to August 2016 where closed or open diaphyseal or metaphyseo- diaphyseal fractures of the tibia (closed or open Gustilo Anderson type 1 through 3B) were included. Simple sequential allocation was used for allotting the patients to two groups, one for interlocking nailing and other for plating. The patients were followed up for clinical, radiographic and functional results. Results Forty patients with 41 involved limbs completed follow up for one year. The duration of surgery and average blood loss during surgery was 75.45±3.03 minutes and 165.00±5.31 ml respectively in case of nailing and 85.05±2.54 minutes and184.29±5.33 ml respectively in case of plating and their difference was statistically significant. In our study union was achieved in less than 20 weeks in 29 (70.8%) of the patients and 25-30 weeks in nine (22%) cases. The average time of union in our study was 19.55±0.69 weeks in case of interlocking nailing and 20.38±1.39 weeks in case of plating and there was no statistically significant difference between the two. However, there is statistically significant difference in the functional score in between the two groups in terms of Lower Extremity Functional Score (LEFS). Delayed union in one case of nailing and two cases of plating, valgus malunion in one case of nailing and joint stiffness in two cases each of nailing and plating were the major complications observed

  9. Immediate versus delayed intramedullary nailing for open fractures of the tibial shaft: a multivariate analysis of factors affecting deep infection and fracture healing.

    PubMed

    Yokoyama, Kazuhiko; Itoman, Moritoshi; Uchino, Masataka; Fukushima, Kensuke; Nitta, Hiroshi; Kojima, Yoshiaki

    2008-10-01

    The purpose of this study was to evaluate contributing factors affecting deep infection and fracture healing of open tibia fractures treated with locked intramedullary nailing (IMN) by multivariate analysis. We examined 99 open tibial fractures (98 patients) treated with immediate or delayed locked IMN in static fashion from 1991 to 2002. Multivariate analyses following univariate analyses were derived to determine predictors of deep infection, nonunion, and healing time to union. The following predictive variables of deep infection were selected for analysis: age, sex, Gustilo type, fracture grade by AO type, fracture location, timing or method of IMN, reamed or unreamed nailing, debridement time (< or =6 h or >6 h), method of soft-tissue management, skin closure time (< or =1 week or >1 week), existence of polytrauma (ISS< 18 or ISS> or =18), existence of floating knee injury, and existence of superficial/pin site infection. The predictive variables of nonunion selected for analysis was the same as those for deep infection, with the addition of deep infection for exchange of pin site infection. The predictive variables of union time selected for analysis was the same as those for nonunion, excluding of location, debridement time, and existence of floating knee and superficial infection. Six (6.1%; type II Gustilo n=1, type IIIB Gustilo n=5) of the 99 open tibial fractures developed deep infections. Multivariate analysis revealed that timing or method of IMN, debridement time, method of soft-tissue management, and existence of superficial or pin site infection significantly correlated with the occurrence of deep infection (P< 0.0001). In the immediate nailing group alone, the deep infection rate in type IIIB + IIIC was significantly higher than those in type I + II and IIIA (P = 0.016). Nonunion occurred in 17 fractures (20.3%, 17/84). Multivariate analysis revealed that Gustilo type, skin closure time, and existence of deep infection significantly correlated with

  10. Plate Versus Intramedullary Nail Fixation of Anterior Tibial Stress Fractures: A Biomechanical Study.

    PubMed

    Markolf, Keith L; Cheung, Edward; Joshi, Nirav B; Boguszewski, Daniel V; Petrigliano, Frank A; McAllister, David R

    2016-06-01

    Anterior midtibial stress fractures are an important clinical problem for patients engaged in high-intensity military activities or athletic training activities. When nonoperative treatment has failed, intramedullary (IM) nail and plate fixation are 2 surgical options used to arrest the progression of a fatigue fracture and allow bone healing. A plate will be more effective than an IM nail in preventing the opening of a simulated anterior midtibial stress fracture from tibial bending. Controlled laboratory study. Fresh-frozen human tibias were loaded by applying a pure bending moment in the sagittal plane. Thin transverse saw cuts, 50% and 75% of the depth of the anterior tibial cortex, were created at the midtibia to simulate a fatigue fracture. An extensometer spanning the defect was used to measure the fracture opening displacement (FOD) before and after the application of IM nail and plate fixation constructs. IM nails were tested without locking screws, with a proximal screw only, and with proximal and distal screws. Plates were tested with unlocked bicortical screws (standard compression plate) and locked bicortical screws; both plate constructs were tested with the plate edge placed 1 mm from the anterior tibial crest (anterior location) and 5 mm posterior to the crest. For the 75% saw cut depth, the mean FOD values for all IM nail constructs were 13% to 17% less than those for the saw cut alone; the use of locking screws had no significant effect on the FOD. The mean FOD values for all plate constructs were significantly less than those for all IM nail constructs. The mean FOD values for all plates were 28% to 46% less than those for the saw cut alone. Anterior plate placement significantly decreased mean FOD values for both compression and locked plate constructs, but the mean percentage reductions for locked and unlocked plates were not significantly different from each other for either plate placement. The percentage FOD reductions for all plate

  11. The healing stages of an intramedullary implanted tibia: A stress strain comparative analysis of the calcification process

    PubMed Central

    Filardi, Vincenzo

    2015-01-01

    Aims The extended usage of unreamed tibial nailing resulted in reports of an increased rate of complications, especially for the distal portion of the tibia. Unreamed nailing favours biology at the expense of the achievable mechanical stability, it is therefore of interest to define the limits of the clinical indications for this method. Extra-articular fractures of the distal tibial metaphysis, meta-diaphyseal junction, and adjacent diaphysis are distinct in their management from impaction derived ‘‘pilon’’ type fractures and mid-diaphyseal fractures. The goals of this work were to gain a thorough understanding of the load-sharing mechanism between unreamed nail and bones in a fractured tibia. With this purpose a complete model of the human leg was realised, simulating a mid-diaphyseal fracture, classified as A2 type 1, according to the AO classification. The analysis of the entire chain allows to have a complete picture of the stress distribution and of the most stressed bones and soft tissues, but, more importantly can overcome problems connected with boundary conditions imposed at single bony components. Methods Model consists of six bony structures: pelvis, femur, patella, fibula, tibia, and a simplified lump of the feet, configured in a standing up position. Their articular cartilage layers, were simulated by 3D membranes of opportune stiffness connecting the different segments. Moreover an unreamed intra-medullary nail Expert Tibial Nail (DePuy Synthes®) stabilized the fractured tibia. A load of 700 N has been applied at the top of pelvis and a part the feet, at the tip, was rigidly fixed. Five different contact interfaces have been imposed at the different bony surfaces in contact. Results Three different conditions were analysed: the initially healthy tibia, the A2 type 1 fractured tibia with the Expert tibial nail implanted, and the follow up stage after complete healing of tibia. Non-linear finite element analysis of the models were performed

  12. Hindfoot Valgus following Interlocking Nail Treatment for Tibial Diaphysis Fractures: Can the Fibula Be Neglected?

    PubMed Central

    Uzun, Metin; Kara, Adnan; Adaş, Müjdat; Karslioğlu, Bülent; Bülbül, Murat; Beksaç, Burak

    2014-01-01

    Purpose. We evaluated whether intramedullary nail fixation for tibial diaphysis fractures with concomitant fibula fractures (except at the distal one-third level) managed conservatively with an associated fibula fracture resulted in ankle deformity and assessed the impact of the ankle deformity on lower extremity function. Methods. Sixty middle one-third tibial shaft fractures with associated fibular fractures, except the distal one-third level, were included in this study. All tibial shaft fractures were anatomically reduced and fixed with interlocking intramedullary nails. Fibular fractures were managed conservatively. Hindfoot alignment was assessed clinically. Tibia and fibular lengths were compared to contralateral measurements using radiographs. Functional results were evaluated using the Knee Injury and Osteoarthritis Outcome Score (KOOS) and the Foot and Ankle Disability Index Score (FADI). Results. Anatomic union, defined as equal length in operative and contralateral tibias, was achieved in 60 fractures (100%). Fibular shortening was identified in 42 fractures (68%). Mean fibular shortening was 1.2 cm (range, 0.5–2 cm). Clinical exams showed increased hindfoot valgus in 42 fractures (68%). The mean KOOS was 88.4, and the mean FADI score was 90. Conclusion. Fibular fractures in the middle or proximal one-third may need to be stabilized at the time of tibial intramedullary nail fixation to prevent development of hindfoot valgus due to fibular shortening. PMID:25544899

  13. Comparison of suprapatellar and infrapatellar intramedullary nailing for tibial shaft fractures: a systematic review and meta-analysis.

    PubMed

    Yang, Liqing; Sun, Yuefeng; Li, Ge

    2018-06-14

    Optimal surgical approach for tibial shaft fractures remains controversial. We perform a meta-analysis from randomized controlled trials (RCTs) to compare the clinical efficacy and prognosis between infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. PubMed, OVID, Embase, ScienceDirect, and Web of Science were searched up to December 2017 for comparative RCTs involving infrapatellar and suprapatellar intramedullary nail in the treatment of tibial shaft fractures. Primary outcomes were blood loss, visual analog scale (VAS) score, range of motion, Lysholm knee scores, and fluoroscopy times. Secondary outcomes were length of hospital stay and postoperative complications. We assessed statistical heterogeneity for each outcome with the use of a standard χ 2 test and the I 2 statistic. The meta-analysis was undertaken using Stata 14.0. Four RCTs involving 293 participants were included in our study. The present meta-analysis indicated that there were significant differences between infrapatellar and suprapatellar intramedullary nail regarding the total blood loss, VAS scores, Lysholm knee scores, and fluoroscopy times. Suprapatellar intramedullary nailing could significantly reduce total blood loss, postoperative knee pain, and fluoroscopy times compared to infrapatellar approach. Additionally, it was associated with an improved Lysholm knee scores. High-quality RCTs were still required for further investigation.

  14. Is intramedullary nailing applicable for distal tibial fractures with ankle joint extension?

    PubMed

    Beytemür, Ozan; Albay, Cem; Adanır, Oktay; Yüksel, Serdar; Güleç, Mehmet Akif

    2016-12-01

    This study aims to evaluate the functional and radiographic results and treatment complications of AO/OTA (Arbeitsgemeinschaft fur Osteosynthesefragen/Orthopaedic Trauma Association) type 43C1 and C2 fractures treated with intramedullary nailing. We retrospectively evaluated 35 AO/OTA type 43C1 and C2 patients (26 males, 9 females; mean age 39.8±16.9 years; range 19 to 82 years) treated with intramedullary nailing. Two interfragmentary screws out of nail were applied in 10 patients (29%), while one interfragmentary screw out of nail was applied in 17 patients (49%). Intramedullary nailing was applied in eight patients (23%) without external screws. Fracture union, union time, alignment problems, and complications were evaluated. Clinical evaluation of patients was conducted using the Olerud and Molander score and by measuring the ankle joint range of motion. Union was achieved in all 35 patients. Mean union time was 16.5±2.8 weeks (range 12 to 24 weeks) and mean Olerud and Molander score was 88±8.24. Varus deformity was detected in one patient, valgus deformity was detected in two patients, and rotation deformity was detected in one patient. Superficial infection was detected in three patients (9%). Deep infection was not detected in any patient. Intramedullary nailing is not contraindicated for simple intra-articular distal tibial fractures. In these fractures, intramedullary nailing performed in accordance with its technique, with an additional percutaneous screw if necessary, is a successful treatment option with high fracture union rates, high functional results, and low complication rates.

  15. Tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator

    PubMed Central

    Kim, Hayoung; Kim, Kap Jung; Ahn, Jae Hoon; Choy, Won Sik; Kim, Yong In; Koo, Jea Yun

    2008-01-01

    The aim of this study was to evaluate the efficacy of tibial lengthening using a reamed type intramedullary nail and an Ilizarov external fixator for the treatment of leg length discrepancy or short stature. This retrospective study was performed on 18 tibiae (13 patients) in which attempts were made to reduce complications. We used an Ilizarov external fixator and a nail (10 mm diameter in 17 tibiae and 11 mm in one tibia) in combination. Average limb lengthening was 4.19 cm (range, 2.5–5.5). The mean duration of external fixation was 12.58 days per centimetre gain in length, and the mean consolidation index was 40.53 (range, 35.45–51.85). All distracted segments healed spontaneously without refracture or malalignment. Gradual limb lengthening using a reamed type intramedullary nail and circular external fixation in combination was found to be reliable and effective and reduced external fixation time with fewer complications. PMID:18415098

  16. [Clinical application of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nail].

    PubMed

    Zhu, Hai-Bing; Wu, Li-Guo; Fang, Zhi-Song; Luo, Cong-Feng; Wang, Qing-Feng; Ma, Yi-Ping; Gao, Hong; Fu, Guo-Hai; Hu, Cheng-Ting

    2012-07-01

    To introduce the clinical method of blocking screws and rooting technique in the treatment of distal tibial fracture with interlocking intramedullary nails. From June 2006 to March 2011, 26 patients with distal tibial fracture were treated with interlocking intramedullary nails using blocking screws and rooting technique, included 18 males and 8 females with an average age of 46.2 years old ranging from 24 to 64 years. According to AO classification: 10 cases of type A1, 4 cases of type A2, 8 cases of type B1, 4 cases of type B2. The average distance of the fractures end to the ankle joint was 85 mm ranging from 55 to 125 mm, the mean time between injured and operation was 4.5 days. The patients were evaluated with pain, range of motion, walking. All cases were followed-up for 6 to 22 months (averaged 15 months). According to Iowa ankle joint grading system,the score was improved from preoperative (66.8 +/- 8.2) to postoperative (94.6 +/- 4.8). All fractures had united, and got satisfactory reduction and stable fixation with no complications had happen such as breakage of screw. Fixation with interlocking intramedullary nail using blocking screws and rooting technique in treating distal tibial fracture, is a safe and effective technique for the improvement of stability.

  17. Tibial lengthening using a humeral intramedullary nail combined with a single-plane external fixator for leg discrepancy in sequelae of poliomyelitis.

    PubMed

    Chen, Daoyun; Chen, Jianmin; Liu, Fanggang; Jiang, Yao

    2011-03-01

    The sequelae of poliomyelitis are the common causes of leg discrepancy. Tibial lengthening is an effective way to solve this problem but it is associated with a high rate of complications. In this study, we combined the use of humeral nail and external fixator in tibial lengthening with the purpose of reducing lengthening complications. Compared with the cases lengthened by a single-plane external fixator alone, this combined strategy was found to be beneficial in maintaining the tibial alignment. Therefore, it can be recommended as a good technique for tibial lengthening in patients with sequelae of poliomyelitis.

  18. Bilateral tibial lengthening over the nail: our experience of 143 cases.

    PubMed

    Motallebi Zadeh, Nader; Mortazavi, Seyedeh Hamideh; Khaki, Siavash; Heidari, Kazem; Karbasi, Ashraf; Ostad Rahimi, Sedigheh

    2014-09-01

    Using lengthening over an intramedullary nail as a technique for cosmetic purposes improves the individuals' quality of life and provides more satisfactory results due to less external fixator period. This study reports a case series of 143 individuals who underwent bilateral tibial lengthening over an intramedullary nail for cosmetic purposes together with the review of parameters related to the surgery and complications. Level of satisfaction was measured with the standard visual analog scale at least 1 year after removal of external fixator. In this study, mean (SD) age of patients was 26.6 (7.26) years. 85 (59.4%) participants were male and 58 (40.6%) were female. Mean end lengthening of all individuals was 6.65 cm. The mean external fixator period was 93.7 days. Complication rate was 0.74 per segment but it decreased to 0.45 when pin-tract infection was excluded. Complications were categorized based on Paley et al.'s classification as 129 problems, 85 obstacles and no sequelae. Interestingly, 44 (30.8%) individuals had no problem and obstacle. Lengthening over an intramedullary nail provides bone formation in equal quality to that obtained by the conventional Ilizarov method, along with lower rate of complications. The large number of individuals involved in our study is a remarkable benefit which could be used as an appropriate sample to compare results for outcomes and complications.

  19. Computational comparison of tibial diaphyseal fractures fixed with various degrees of prebending of titanium elastic nails and with and without end caps.

    PubMed

    Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Han; Chang, Chih-Wei; Ho, Yi-Hung; Li, Chun-Ting; Peng, Yao-Te

    2016-10-01

    Elastic stable intramedullary nailing (ESIN) is a treatment strategy for the management of diaphyseal long-bone fractures in adolescents and children, but few studies have investigated the mechanical stability of tibial diaphyseal fractures treated with various degrees of prebending of the elastic nails. Therefore, the aim of this study was to compare the mechanical stability, including the gap deformation and nail dropping, of a tibia fracture with various fracture sites and fixed with various degrees of prebending of the elastic nails by the finite element method. Furthermore, the contribution of end caps to stability was taken into consideration in the simulation. A tibia model was developed with a transverse fracture at the proximal, middle and distal parts of the diaphysis, and fixed with three degrees of prebending of elastic nails, including those equal to, two times and three times the diameter of the intramedullary canal. The outer diameter of the nail used in the computation was 3.5mm, and the fractured tibia was fixed with two elastic double C-type nails. Furthermore, the proximal end of each nail was set to free or being tied to the surrounding bone by a constraint equation to simulate with or without using end caps. The results indicated that using end caps can prevent the fracture gap from collapsing by stopping the ends of the nails from dropping back in all prebending conditions and fracture patterns, and increasing the prebending of the nails to a degree three times the diameter of the canal reduced the gap shortening and the dropping distance of the nail end in those without using end caps under axial compression and bending. Insufficient prebending of the nails and not using end caps caused the gap to collapse and the nail to drop back at the entry point under loading. Using end caps or increasing the prebending of the nails to three times the diameter of the canal is suggested to stop the nail from dropping back and thus produce a more stable

  20. Suprapatellar Versus Infrapatellar Tibial Nail Insertion: A Prospective Randomized Control Pilot Study.

    PubMed

    Chan, Daniel S; Serrano-Riera, Rafael; Griffing, Rebecca; Steverson, Barbara; Infante, Anthony; Watson, David; Sagi, H Claude; Sanders, Roy W

    2016-03-01

    The purpose of this OTA-approved pilot study was to compare the clinical and functional outcomes of the knee joint after infrapatellar (IP) versus suprapatellar (SP) tibial nail insertion. Prospective, randomized. Level I trauma center. After institutional review board approval, skeletally mature patients with OTA 42 tibial shaft fractures were randomized into either an IP or SP nail insertion group after informed consent was obtained. The SP also underwent prenail and postnail insertion patella-femoral (PF) joint arthroscopy. Patients underwent follow-up (6 weeks, 3, 6, and 12 months) with standard radiographs, as well as visual analog score and pain diagram documentation. At the 6-month and 12-month visits, knee function questionnaires (Lysholm knee scale and SF-36) were completed. Magnetic resonance imaging/image (MRI) of the affected knee was obtained at 12 months. Ten patients in each group were required for a power analysis for the anticipated larger randomized control trial, but enrollment in each arm was not limited because of known problems with patient follow-up over a 12-month period. A total of 41 patients/fractures were enrolled in this study. Of those, only 25 patients/fractures (14 IP, 11 SP) fully complied with and completed 12 months of follow-up. Six of 11 SP presented with articular changes (chondromalacia) in the PF joint during the preinsertion arthroscopy. Three patients displayed a change in the articular cartilage based on postnail insertion arthroscopy. At 12 months, all fractures in both groups had proceeded to union. There were no differences between the affected and unaffected knee with respect to range of motion. Functional visual analog score and Lysholm knee scores showed no significant differences between groups (P > 0.05). The SF-36v2 comparison also revealed no significant differences in the overall score, all 4 mental components, and 3/4 physical components (P > 0.05). The bodily pain component score was superior in the SP group

  1. Finite element analysis of intramedullary nailing and double locking plate for treating extra-articular proximal tibial fractures.

    PubMed

    Chen, Fancheng; Huang, Xiaowei; Ya, Yingsun; Ma, Fenfen; Qian, Zhi; Shi, Jifei; Guo, Shuolei; Yu, Baoqing

    2018-01-16

    Proximal tibia fractures are one of the most familiar fractures. Surgical approaches are usually needed for anatomical reduction. However, no single treatment method has been widely established as the standard care. Our present study aims to compare the stress and stability of intramedullary nails (IMN) fixation and double locking plate (DLP) fixation in the treatment of extra-articular proximal tibial fractures. A three-dimensional (3D) finite element model of the extra-articular proximal tibial fracture, whose 2-cm bone gap began 7 cm from the tibial plateau articular surface, was created fixed by different fixation implants. The axial compressive load on an adult knee during single-limb stance was imitated by an axial force of 2500 N with a distribution of 60% to the medial compartment, while the distal end was fixed effectively. The equivalent von Mises stress and displacement of the model was used as the output measures for analysis. The maximal equivalent von Mises stress value of the system in the IMN model was 293.23 MPa, which was higher comparing against that in the DLP fixation model (147.04 MPa). And the mean stress of the model in the IMN model (9.25 MPa) was higher than that of the DLP fixation system in terms of equivalent von Mises stress (EVMS) (P < 0.0001). The maximal value of displacement (sum) in the IMN system was 8.82 mm, which was lower than that in the DLP fixation system (9.48 mm). This study demonstrated that the stability provided by the locking plate fixation system was superior to the intramedullary nails fixation system and served as an alternative fixation for the extra-articular proximal tibial fractures of young patients.

  2. Early Tibiotalocalcaneal Arthrodesis Intramedullary Nail for Treatment of a Complex Tibial Pilon Fracture (AO/OTA 43-C).

    PubMed

    Hsu, Andrew R; Szatkowski, Jan P

    2015-06-01

    Management of severely comminuted, complete articular tibial pilon fractures (AO/OTA 43-C) remains a challenge, with few treatment options providing good clinical outcomes. Open reduction and internal fixation of the tibial plafond, tibiotalar arthrodesis, and salvage hindfoot reconstruction procedures are all associated with surgical complications and functional limitations. In this report, we present a case of a complex pilon fracture in a patient with multiple medical comorbidities and socioeconomic disadvantages that was successfully and acutely treated with a retrograde tibiotalocalcaneal hindfoot arthrodesis nail. At final follow-up examination, the patient had decreased pain, a stable plantigrade foot, and could ambulate with normal shoes without any assistive devices. Therapeutic, Level IV: Case series. © 2014 The Author(s).

  3. Anatomic aspects of tibiotalocalcaneal nail arthrodesis.

    PubMed

    Hyer, Christopher F; Cheney, Nick

    2013-01-01

    During the past 15 years, tibiotalocalcaneal nail arthrodesis has become an established procedure for the treatment of specific disorders of the hindfoot and ankle. However, controversy exists regarding the proper starting point for obtaining and maintaining the correct hindfoot position to allow successful fusion. One of the challenges with this procedure is aligning the tibial canal with the central talus and calcaneus for placement of the intramedullary nail. We performed a cadaver study to evaluate the radiographic and anatomic position of the tibial canal and the central talus as it relates to placement of a retrograde tibiotalocalcaneal nail. In our subjects, guide wires directed in an antegrade fashion down the tibial canal were more likely to enter lateral to the midline of the talus and miss the calcaneal body medially. These data have revealed a mismatch among the central axis of the tibia, talus, and calcaneus. Surgeons must pay careful attention to wire placement across these 3 bone segments during retrograde tibiotalocalcaneal nailing. Copyright © 2013 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  4. [Should one choose the nail or the plate in treating a leg fracture?].

    PubMed

    Vives, P; Massy, E; Dubois, P; Decoopmann, P

    1975-12-01

    The authors have analysed the results of 126 tibial fractures treated by blind nailing with reaming and 112 tibial fractures treated by plating. They noted 5 septic complications after nailing, after plating, one non-union after nailing and 12 after plating, 3 malunions after nailing and 2 after plating. The cases treated by nailing united earlier. The Authors conclude that nailing is a more fiable technique than plating, and that the only fractures which should be plated are those which are not fit for nailing.

  5. Nail or plate in the management of distal extra-articular tibial fracture, what is better? Valutation of outcomes

    PubMed Central

    Bisaccia, Michele; Cappiello, Andrea; Meccariello, Luigi; Rinonapoli, Giuseppe; Falzarano, Gabriele; Medici, Antonio; Vicente, Cristina Ibáñez; Piscitelli, Luigi; Stano, Verdiana; Bisaccia, Olga; Caraffa, Auro

    2018-01-01

    Introduction: Distal tibial fractures are the most common long bone fractures. Several studies focusing on the methods of treatment of displaced distal tibial fractures have been published. To date, locked plates, intramedullary nails and external fixation are the three most used techniques. The aim of our study was to compare intramedullary nail (IMN) and locked plate (LP) for treatment of this kind of fracture. Materials and methods: We collected data on 81 patients with distal tibial fractures (distance from the joint between 40 and 100 mm) and we divided into two groups: IMN and LP. We compared in the 2 groups the mean operation time, the mean union time, the infection rate the rate of malunion and nonunion, the full weight bearing time. Results: No patient in the two groups developed a nonunion. None of the patients obtained a fair or poor outcome. Overall 52 patients obtained an excellent result (69.3%) and 23 obtained a good result (30.6%). Discussion: Our study results indicate a superiority of IMN over LP in terms of lower rates of infections and statistically significant shorter time to full weight bearing. Whereas LP appeared to be advantageous over IMN in terms of leading to a better anatomical and fixed reductions of the fracture and a lower rate of union complications. The two treatments achieved comparable results in terms of operation time, hospital stay, union time and functional outcomes. PMID:29469802

  6. Semiextended approach for intramedullary nailing via a patellar eversion technique for tibial-shaft fractures: Evaluation of the patellofemoral joint.

    PubMed

    Yasuda, Tomohiro; Obara, Shu; Hayashi, Junji; Arai, Masayuki; Sato, Kaoru

    2017-06-01

    Intramedullary nail fixation is a common treatment for tibial-shaft fractures, and it offers a better functional prognosis than other conservative treatments. Currently, the primary approach employed during intramedullary nail insertion is the semiextended position is the suprapatellar approach, which involves a vertical incision of the quadriceps tendon Damage to the patellofemoral joint cartilage has been highlighted as a drawback associated with this approach. To avoid this issue, we perform surgery using the patellar eversion technique and a soft sleeve. This method allows the articular surface to be monitored during intramedullary nail insertion. We arthroscopically assessed the effect of this technique on patellofemoral joint cartilage. The patellar eversion technique allows a direct view and protection of the patellofemoral joint without affecting the patella. Thus, damage to the patellofemoral joint cartilage can be avoided. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Role of the fibula in the stability of diaphyseal tibial fractures fixed by intramedullary nailing.

    PubMed

    Galbraith, John G; Daly, Charles J; Harty, James A; Dailey, Hannah L

    2016-10-01

    For tibial fractures, the decision to fix a concomitant fibular fracture is undertaken on a case-by-case basis. To aid in this clinical decision-making process, we investigated whether loss of integrity of the fibula significantly destabilises midshaft tibial fractures, whether fixation of the fibula restores stability to the tibia, and whether removal of the fibula and interosseous membrane for expediency in biomechanical testing significantly influences tibial interfragmentary mechanics. Tibia/fibula pairs were harvested from six cadaveric donors with the interosseous membrane intact. A tibial osteotomy fracture was fixed by reamed intramedullary (IM) nailing. Axial, torsion, bending, and shear tests were completed for four models of fibular involvement: intact fibula, osteotomy fracture, fibular plating, and resected fibula and interosseous membrane. Overall construct stiffness decreased slightly with fibular osteotomy compared to intact bone, but this change was not statistically significant. Under low loads, the influence of the fibula on construct stability was only statistically significant in torsion (large effect size). Fibular plating stiffened the construct slightly, but this change was not statistically significant compared to the fibular osteotomy case. Complete resection of the fibula and interosseous membrane significantly decreased construct torsional stiffness only (large effect size). These results suggest that fixation of the fibula may not contribute significantly to the stability of diaphyseal tibial fractures and should not be undertaken unless otherwise clinically indicated. For testing purposes, load-sharing through the interosseous membrane contributes significantly to overall construct mechanics, especially in torsion, and we recommend preservation of these structures when possible. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Incidence of infection after early intramedullary nailing of open tibial shaft fractures stabilized with pinless external fixators

    PubMed Central

    Kulshrestha, Vikas

    2008-01-01

    Background: A major drawback of conventional fixator system is the penetration of fixator pins into the medullary canal. The pins create a direct link between the medullary cavity and outer environment, leading to higher infection rates on conversion to intramedullary nailing. This disadvantage is overcome by the AO pinless fixator, in which the trocar points are clamped onto the outer cortex without penetrating it. This study was designed to evaluate the role of AO pinless fixators in primary stabilization of open diaphyseal tibial fractures that received staged treatment because of delayed presentation or poor general condition. We also analyzed the rate of infection on early conversion to intramedullary nail. Materials and Methods: This study is a retrospective review of 30 open diaphyseal fractures of tibia, which were managed with primary stabilization with pinless fixator and early exchange nailing. Outcome was evaluated in terms of fracture union and rate of residual infection. The data were compared with that available in the literature. Results: All the cases were followed up for a period of 2 years. The study includes Gustilo type 1 (n=10), 14 Gustilo type 2 (n=14), and type3 (n=6) cases. 6 cases (20%) had clamp site infection, 2 cases (6.7%) had deep infection, and in 28 cases (93%) the fracture healed and consolidated well. Conclusion: This study has highlighted the valuable role of pinless external fixator in the management of open tibial fractures in terms of safety and ease of application as well as the advantage of early conversion to intramedullary implant without the risk of deep infection. PMID:19753227

  9. Intramedullary nailing in opening wedge high tibial osteotomy-in vitro test for validation of a method of fixation.

    PubMed

    Burchard, Rene; Katerla, Denise; Hammer, Marina; Pahlkötter, Anke; Soost, Christian; Dietrich, Gerhard; Ohrndorf, Arne; Richter, Wolfgang; Lengsfeld, Markus; Christ, Hans-Jürgen; Graw, Jan Adriaan; Fritzen, Claus-Peter

    2018-02-01

    Opening wedge high tibial osteotomy (HTO) as a treatment in unicompartimental osteoarthritis of the knee can significantly relieve pain and prevent or at least delay an early joint replacement. The fixation of the osteotomy has undergone development and refinements during the last years. The angle-stable plate fixator is currently one of the most commonly used plates in HTOs. The angular stable fixation between screws and the plate offers a high primary stability to retain the correction with early weight-bearing protocols. This surgical technique is performed as a standard of care and generally well tolerated by the patients. Nevertheless, some studies observed that many patients complained about discomfort related to the implant. Therefore, the stability of two different intramedullary nails, a short implant used in humeral fractures and a long device used in tibial fractures for stabilization in valgus HTOs, was investigated as an alternative fixation technique. The plate fixator was defined as reference standard. Nine synthetic tibia models were standardly osteotomized and stabilized by one of the fixation devices. Axial compression was realized using a special testing machine and two protocols were performed: a multi-step fatigue test and a load-to-failure test. Overall motion, medial, and lateral displacements were documented. Fractures always occurred at the lateral cortex. Axial cyclic loading up to 800 N was tolerated by all implants without failure. The tibia nail provided highest fatigue strength under the load-to-failure conditions. The results suggest that intramedullary nailing might be used as an alternative concept in HTO.

  10. Individual risk factors for deep infection and compromised fracture healing after intramedullary nailing of tibial shaft fractures: a single centre experience of 480 patients.

    PubMed

    Metsemakers, W-J; Handojo, K; Reynders, P; Sermon, A; Vanderschot, P; Nijs, S

    2015-04-01

    Despite modern advances in the treatment of tibial shaft fractures, complications including nonunion, malunion, and infection remain relatively frequent. A better understanding of these injuries and its complications could lead to prevention rather than treatment strategies. A retrospective study was performed to identify risk factors for deep infection and compromised fracture healing after intramedullary nailing (IMN) of tibial shaft fractures. Between January 2000 and January 2012, 480 consecutive patients with 486 tibial shaft fractures were enrolled in the study. Statistical analysis was performed to determine predictors of deep infection and compromised fracture healing. Compromised fracture healing was subdivided in delayed union and nonunion. The following independent variables were selected for analysis: age, sex, smoking, obesity, diabetes, American Society of Anaesthesiologists (ASA) classification, polytrauma, fracture type, open fractures, Gustilo type, primary external fixation (EF), time to nailing (TTN) and reaming. As primary statistical evaluation we performed a univariate analysis, followed by a multiple logistic regression model. Univariate regression analysis revealed similar risk factors for delayed union and nonunion, including fracture type, open fractures and Gustilo type. Factors affecting the occurrence of deep infection in this model were primary EF, a prolonged TTN, open fractures and Gustilo type. Multiple logistic regression analysis revealed polytrauma as the single risk factor for nonunion. With respect to delayed union, no risk factors could be identified. In the same statistical model, deep infection was correlated with primary EF. The purpose of this study was to evaluate risk factors of poor outcome after IMN of tibial shaft fractures. The univariate regression analysis showed that the nature of complications after tibial shaft nailing could be multifactorial. This was not confirmed in a multiple logistic regression model, which

  11. Tibiotalocalcaneal arthrodesis with a retrograde intramedullary nail: a biomechanical analysis of the effect of nail length.

    PubMed

    Noonan, Timothy; Pinzur, Michael; Paxinos, Odysseas; Havey, Robert; Patwardhin, Avinash

    2005-04-01

    Fatigue fractures of the tibia have been observed at the level of the proximal end of the nail after successful tibiocalcaneal arthrodesis with a retrograde intramedullary device. To study the effect of nail length, five matched pairs of cadaver tibiae were instrumented with strain gauges and potted in methylmethacrylate from a level 3 cm proximal to the distal medial malleolus to simulate a successful tibiocalcaneal arthrodesis. A standard length (15 cm) ankle arthrodesis nail and an identical longer device terminating in the proximal tibial metaphysis were inserted in each paired tibia using appropriate technique. The strain of the posterior cortex of the tibia was recorded under bending moments of up to 50 Nm for each intact specimen after nail insertion and after proximal locking of the nail. The nails were then exchanged between the specimens of the same pairs and the experiment was repeated to insure uniformity. The standard length locked nail increased the principal strain of the posterior cortex of the tibia at the level of the proximal screw holes 5.3 times more than the locked long nail (353 and 67 microstrains), respectively. This stress concentration was not observed when the proximal extent of the nail terminated within the proximal tibial metaphysis. A successful tibiocalcaneal arthrodesis with a standard length locked intramedullary nail creates stress concentration around the proximal screw holes that may be responsible for the fractures observed clinically. This study supports the use of a "long" retrograde locked intramedullary nail for tibiocalcaneal arthrodesis in patients with systemic or localized osteopenia.

  12. Fibular fixation as an adjuvant to tibial intramedullary nailing in the treatment of combined distal third tibia and fibula fractures: a biomechanical investigation.

    PubMed

    Morin, Paul M; Reindl, Rudolf; Harvey, Edward J; Beckman, Lorne; Steffen, Thomas

    2008-02-01

    Distal third tibia fractures have classically been treated with standard plating, but intramedullary (IM) nailing has gained popularity. Owing to the lack of interference fit of the nail in the metaphyseal bone of the distal tibia, it may be beneficial to add rigid plating of the fibula to augment the overall stability of fracture fixation in this area. This study sought to assess the biomechanical effect of adding a fibular plate to standard IM nailing in the treatment of distal third tibia and fibula fractures. Eight cadaveric tibia specimens were used. Tibial fixation consisted of a solid titanium nail locked with 3 screws distally and 2 proximally, and fibular fixation consisted of a 3.5 mm low-contact dynamic compression plate. A section of tibia and fibula was removed. Testing was accomplished with an MTS machine. Each leg was tested 3 times; with and without a fibular plate and with a repetition of the initial test condition. Vertical displacements were tested with an axial load up to 500 N, and angular rotation was tested with torques up to 5 N*m. The difference in axial rotation was the only statistically significant finding (p = 0.003), with fibular fixation resulting in 1.1 degrees less rotation through the osteotomy site (17.96 degrees v. 19.10 degrees ). Over 35% of this rotational displacement occurred at the nail-locking bolt interface with the application of small torsional forces. Fibular plating in addition to tibial IM fixation of distal third tibia and fibula fractures leads to slightly increased resistance to torsional forces. This small improvement may not be clinically relevant.

  13. A comparative study of intramedullary interlocking nailing and minimally invasive plate osteosynthesis in extra articular distal tibial fractures.

    PubMed

    Daolagupu, Arup K; Mudgal, Ashwani; Agarwala, Vikash; Dutta, Kaushik K

    2017-01-01

    Extraarticular distal tibial fractures are among the most challenging fractures encountered by an orthopedician for treatment because of its subcutaneous location, poor blood supply and decreased muscular cover anteriorly, complications such as delayed union, nonunion, wound infection, and wound dehiscence are often seen as a great challenge to the surgeon. Minimally invasive plate osteosynthesis (MIPO) and intramedullary interlocking nail (IMLN) are two well-accepted and effective methods, but each has been historically related to complications. This study compares clinical and radiological outcome in extraarticular distal tibia fractures treated by intramedullary interlocking nail (IMLN) and minimally invasive plate osteosynthesis (MIPO). 42 patients included in this study, 21 underwent IMLN and 21 were treated with MIPO who met the inclusion criteria and operated between June 2014 and May 2015. Patients were followed up for clinical and radiological evaluation. In IMLN group, average union time was 18.26 weeks compared to 21.70 weeks in plating group which was significant ( P < 0.0001). Average time required for partial and full weight bearing in the nailing group was 4.95 weeks and 10.09 weeks respectively which was significantly less ( P < 0.0001) as compared to 6.90 weeks and 13.38 weeks in the plating group. Lesser complications in terms of implant irritation, ankle stiffness, and infection, were seen in interlocking group as compared to plating group. Average functional outcome according to American Orthopedic Foot and Ankle Society score was measured which came out to be 96.67. IMLN group was associated with lesser duration of surgery, earlier weight bearing and union rate, lesser incidence of infection and implant irritation which makes it a preferable choice for fixation of extra-articular distal tibial fractures. However, larger randomized controlled trials are required for confirming the results.

  14. Retrograde nailing for distal third femoral shaft fractures: a prospective study.

    PubMed

    Acharya, K N; Rao, M R

    2006-12-01

    To evaluate the postoperative knee function and results of unreamed retrograde nailing for distal third femoral shaft fractures. Between January 2002 and 2003 inclusive, a consecutive series of 27 patients (with 28 fractures) who underwent retrograde nailing were prospectively evaluated. Outcome measures were union time, initiation of weight bearing, deformity and shortening, functional length of the nail, knee function assessed using a modified Knee Society Knee Score. Correlations between union time and other variables were also studied. In these patients 26 (93%) of the 28 fractures achieved union, of which 5 underwent dynamisation; the mean union time for the other 21 fractures was 4.4 months. Angular malalignment was present in 4 patients and shortening in 4 others. There was negligible correlation between union time and variables of nail-canal diameter mismatch, functional length of nail, fracture geometry, or initiation of partial weight bearing ambulation. Knee flexion of more than 100 degrees was achieved in 26 patients. 19 patients had anterior knee pain and 10 had instability. By the end of one year, excellent or good scores for pain and function were recorded in 77% and 73% respectively, of the 26 patients. In view of such favourable union rates but significant deterioration in overall knee joint function, at best retrograde nailing is a reliable alternative in the management of selected complicated fractures of the distal femoral shaft.

  15. Percutaneous or Open Reduction of Closed Tibial Shaft Fractures During Intramedullary Nailing Does Not Increase Wound Complications, Infection or Nonunion Rates.

    PubMed

    Auston, Darryl A; Meiss, Jordan; Serrano, Rafael; Sellers, Thomas; Carlson, Gregory; Hoggard, Timothy; Beebe, Michael; Quade, Jonathan; Watson, David; Simpson, Robert Bruce; Kistler, Brian; Shah, Anjan; Sanders, Roy; Mir, Hassan R

    2017-04-01

    To compare the incidence of complications (wound, infection, and nonunion) among those patients treated with closed, percutaneous, and open intramedullary nailing for closed tibial shaft fractures. Retrospective review. Multiple trauma centers. Skeletally mature patients with closed tibia fractures amenable to treatment with an intramedullary device. Intramedullary fixation with closed, percutaneous, or open reduction. Superficial wound complication, deep infection, nonunion. A total of 317 tibial shaft fractures in 315 patients were included in the study. Two-hundred fractures in 198 patients were treated with closed reduction, 61 fractures in 61 patients were treated with percutaneous reduction, and 56 fractures in 56 patients were treated with formal open reduction. The superficial wound complication rate was 1% (2/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 3.6% (2/56) for the open group with no statistical difference between the groups (P = 0.179). The deep infection rate was 2% (4/200) for the closed group, 1.6% (1/61) for the percutaneous group, and 7.1% (4/56) for the open group with no significant difference between the groups (P = 0.133). Nonunion rate was 5.0% (10/200) for the closed group, 4.9% (3/61) for the percutaneous group, and 7.1% (4/56) for the open group, with no statistical difference between the groups (P = 0.492). This is the largest reported series of closed tibial shaft fractures nailed with percutaneous and open reduction. Percutaneous or open reduction did not result in increased wound complications, infection, or nonunion rates. Carefully performed percutaneous or open approaches can be safely used in obtaining reduction of difficult tibial shaft fractures treated with intramedullary devices. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  16. Fat embolism syndrome after nailing an isolated open tibial fracture in a stable patient: a case report.

    PubMed

    Aparicio, Gustavo; Soler, Isabel; López-Durán, Luis

    2014-04-14

    Fat embolism syndrome is a potentially fatal complication of long bone fractures. It is usually seen in the context of polytrauma or a femoral fracture. There are few reports of fat embolism syndrome occurring after isolated long bone fractures other than those of the femur. We describe a case of fat embolism syndrome in a 33-year-old Caucasian man. He was being seen for an isolated Gustilo's grade II open tibial fracture. He was deemed clinically stable, so we proceeded to treat the fracture with intramedullary reamed nailing. He developed fat embolism syndrome intraoperatively and was treated successfully. This case caused us to question the use of injury severity scoring for isolated long bone fractures. It suggests that parameters that have been described in the literature other than that the patient is apparently clinically stable should be used to establish the best time for nailing a long bone fracture, thereby improving patient safety.

  17. Fat embolism syndrome after nailing an isolated open tibial fracture in a stable patient: a case report

    PubMed Central

    2014-01-01

    Background Fat embolism syndrome is a potentially fatal complication of long bone fractures. It is usually seen in the context of polytrauma or a femoral fracture. There are few reports of fat embolism syndrome occurring after isolated long bone fractures other than those of the femur. Case presentation We describe a case of fat embolism syndrome in a 33-year-old Caucasian man. He was being seen for an isolated Gustilo’s grade II open tibial fracture. He was deemed clinically stable, so we proceeded to treat the fracture with intramedullary reamed nailing. He developed fat embolism syndrome intraoperatively and was treated successfully. Conclusion This case caused us to question the use of injury severity scoring for isolated long bone fractures. It suggests that parameters that have been described in the literature other than that the patient is apparently clinically stable should be used to establish the best time for nailing a long bone fracture, thereby improving patient safety. PMID:24731759

  18. Anterior knee pain and thigh muscle strength after intramedullary nailing of a tibial shaft fracture: an 8-year follow-up of 28 consecutive cases.

    PubMed

    Väistö, Olli; Toivanen, Jarmo; Kannus, Pekka; Järvinen, Markku

    2007-03-01

    Chronic anterior knee pain is a common complication after intramedullary nailing of a tibial shaft fracture. The source of pain is often not known, although it correlates with a simultaneous decrease in thigh muscle strength. No long-term follow-up study has assessed whether weakness of the thigh muscles is associated with anterior knee pain after the procedure in question. Prospective study. University Hospital of Tampere, University of Tampere. The muscular performance of 40 consecutive patients with a nailed tibial shaft fracture was tested isokinetically in a follow-up examination an average of 3.2 +/- 0.4 (SD) years after the initial surgery. An 8-year follow-up was possible in 28 of these cases. Isokinetic muscle strength measurements were made in 28 patients at an average 8.1 +/- 0.3 (SD) years after nail insertion and an average 6.6 +/- 0.3 (SD) years after nail extraction. All nails were extracted at an average 1.6 +/- 0.2 years after the nailing. : Seven patients were painless initially and still were at final follow-up (never pain, or NP). In 13 patients, the previous symptom of anterior knee pain was no longer present at final follow-up [pain, no pain (PNP)], and the remaining 8 had anterior knee pain initially and at final follow-up [always pain group (AP)]. With reference to the hamstring muscles, the mean peak torque difference between the injured and uninjured limb was -2.2% +/- 12% in the NP group, 1.6% +/- 15% in the PNP group, and 10.3% +/- 30% in the AP group at a speed of 60 degrees/second (Kruskal-Wallis test; chi(2) = 1.0; P = 0.593). At a speed of 180 degrees/second, the corresponding differences were -2.9% +/- 23% and 7.0% +/- 19% and 4.4% +/- 16% (Kruskal-Wallis test; chi = 1.7; P = 0.429). With reference to the quadriceps muscles, the mean peak torque difference was -2.8% +/- 9% in the NP group, 5.9% +/- 15% in the PNP group, and -13.0% +/- 16% in the AP group at a speed of 60 degrees/second (Kruskal-Wallis test; chi(2) = 7.9; P = 0

  19. Tibiotalocalcaneal arthrodesis using a dynamically locked retrograde intramedullary nail.

    PubMed

    Pelton, Kevin; Hofer, Jason K; Thordarson, David B

    2006-10-01

    Tibiotalocalcaneal arthrodesis is an important salvage method for patients with complex hindfoot problems, including Charcot arthropathy, osteonecrosis of the talus, combined arthritis of the ankle and subtalar joint, and failed total ankle arthroplasty. This study evaluated the results of a dynamic retrograde intramedullary nail for fixation with posterior to anterior distal interlocking screws placed through the calcaneus for tibiotalocalcaneal fusion. Thirty-three consecutive tibiotalocalcaneal fusions were done by a single surgeon (DBT) and were stabilized with a dynamic retrograde intramedullary nail. Time to fusion, impaction of the nail relative to the intramedullary canal, nail-tibial angle, and complications were noted. Average followup was 14 months. Twenty-nine of 33 feet (88%) fused at an average of 3.7 months after surgery. Average impaction of the nail was 2.3 (0.5 to 5.0) mm. Cortical hypertrophy at the tip of the rod or at the proximal interlocking screw was noted in 13 of 27 patients. A trend toward a higher nonunion rate was noted in patients with an increased nail-tibial angle. Dynamic retrograde intramedullary nailing for fixation of the tibiotalocalcaneal fusions is a good method of stabilizing this complex fusion construct.

  20. Complications and functional recovery in treatment of femoral shaft fractures with unreamed intramedullary nailing.

    PubMed

    Sadic, Sahmir; Custovic, Svemir; Smajic, Nedim; Fazlic, Mirsad; Vujadinovic, Aleksandar; Hrustic, Asmir; Jasarevic, Mahir

    2014-01-01

    Fracture of the femoral shaft is a common fracture encountered in orthopedic practice. In the 1939, Küntscher introduced the concept of intramedullary nailing for stabilization of long bone fractures. Intramedullary nailing has revolutionized the treatment of fractures. The study included 37 male patients and 13 female patients, averaged 39 +/- 20.5 years (range, 16 to 76 years). There were 31 left femurs and 21 right femurs fractured. 46 fractures were the result of blunt trauma. Low energy trauma was the cause of fractures in six patients, of which five in elderly females. 49 fractures were closed. Healing time given in weeks was 19.36 +/- 6.1. The overall healing rate was 93.6%. There were three (6.25%) major complications nonunion. There were one (2%) delayed union, one (2%) rotational malunion and no infection. The shortening of 1 cm were in two patients. Antercurvatum of 10 degrees was found in one patient. There was no statistically significant reduction of a motion in the hip and knee (p < 0.05). There was statistically significant in the thigh (knee extensors) muscle weakness (p < 0.001). : Intramedullary nailing is the treatment of choice for femoral shaft fractures.

  1. Complications and Functional Recovery in Treatment of Femoral Shaft Fractures with Unreamed Intramedullary Nailing

    PubMed Central

    Sadic, Sahmir; Custovic, Svemir; Smajic, Nedim; Fazlic, Mirsad; Vujadinovic, Aleksandar; Hrustic, Asmir; Jasarevic, Mahir

    2014-01-01

    ABSTRACT Introduction: Fracture of the femoral shaft is a common fracture encountered in orthopedic practice. In the 1939, Küntscher introduced the concept of intramedullary nailing for stabilization of long bone fractures. Intramedullary nailing has revolutionized the treatment of fractures. Material and methods: The study included 37 male patients and 13 female patients, averaged 39±20,5 years (range, 16 to 76 years). Results and discussion: There were 31 left femurs and 21 right femurs fractured. 46 fractures were the result of blunt trauma. Low energy trauma was the cause of fractures in six patients, of which five in elderly females. 49 fractures were closed. Healing time given in weeks was 19,36 ± 6,1. The overall healing rate was 93,6%. There were three (6,25%) major complications nonunion. There were one (2%) delayed union, one (2%) rotational malunion and no infection. The shortening of 1 cm were in two patients. Antercurvatum of 10 degrees was found in one patient. There was no statistically significant reduction of a motion in the hip and knee (p<0.05). There was statistically significant in the thigh (knee extensors) muscle weakness (p<0.001). Conclusion: Intramedullary nailing is the treatment of choice for femoral shaft fractures. PMID:24783908

  2. [Comparison of effect between early and delayed in primary intramedullary nailing combined with locked plate fixation for the treatment of multi-segments tibial fractures of type].

    PubMed

    Gao, Wei-qiang; Hu, Jiang-hai; Gu, Zhu-chao; Zhang, Huai-xian; Min, Peng; Zhang, Lin-jun; Yu, Wen-wen; Wang, Guang-lin

    2015-02-01

    To compare the clinical results of early and delayed intramedullary nailing and locked plating for the treatment of multi-segments tibial fractures of type AO/ASIF-42C2. Between January 2010 and January 2013,45 patients with multi-segments closed tibial fractures of AO/ASIF-42C2 were treated by early primary intramedullary nailing and locked plating in 20 cases as early group and delayed in 25 cases as delayed group. In early group,20 cases included 13 males and 7 females with an average age of (37.9±14.3) years old ranging from 20 to 56 years;according to soft tissue injury Tscherne classification, 8 fractures were frade I,12 were grade II. In delayed group, 25 cases included 17 males and 8 females with an average age of (38.7±17.2) years old ranging from 24 to 55 years,4 fractures were grade I ,19 were grade II ,2 were grade III. The operative time, blood loss, hospital stay,fracture healing time and complications were recorded. At final follow-up, the Johner-Wruhs score were used to evaluate functional efficacy, and the posterior-anterior and lateral X-ray to evaluate fracture reduction and alignment. All the patients were followed up for (12.5±2.5) months in early group and (13.2±2.8) months in delayed group (P>0.05). No wounds infections were happened. At the last follow-up, the mean range of knee joint was 10°-0°-120°. According to Johner-Wruhs scoring,there were 15 cases in excellent,3 in good,fair in 2 in early group; 21 in excellent,2 in good,2 in fair. The average operative time,blood loss had no significant differences between two groups (P>0.05), but hospital stay in early group was significantly shorter than those in delayed group(P<0.05). Average fracture healing time of early group and delayed group were (5.3±2.6) months and (6.0±2.9) months, respectively (P>0.05). For multi-segments tibial fractures of type AO/ASIF-42C2 with preoperative minor soft tissue injuries lighter of Tscherne grade I or II, early primary intramedullary nailing and

  3. Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures

    PubMed Central

    2014-01-01

    Objective The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. Methods A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Results Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p < 0.001). The healing rate in patients with more than 1 year follow-up was significantly higher in RSIN group for femoral and tibial fractures (both p < 0.05). In RSIN group, no nail breakage or loosening occurred, but radial nerve injury and incision infection were respectively observed in one patient with humeral fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p < 0.05). However, there were no significant differences in the excellent and good rate of shoulder, elbow, knee, and ankle joint functional recovery between RSIN group and IIN group. Conclusion RSIN may be a reliable and practical alternative method for the treatment of long bone fractures. PMID:25047454

  4. Comparison of our self-designed rotary self-locking intramedullary nail and interlocking intramedullary nail in the treatment of long bone fractures.

    PubMed

    Liu, Bailian; Xiong, Ying; Deng, Hong; Gu, Shao; Jia, Fu; Li, Qunhui; Wang, Daxing; Gan, Xuewen; Liu, Wei

    2014-07-21

    The purpose of this study is to compare the clinical effects of our self-designed rotary self-locking intramedullary nail (RSIN) and interlocking intramedullary nail (IIN) for long bone fractures. A retrospective study was performed in 1,704 patients who suffered bone fractures and underwent RSIN or IIN operation in our hospital between March 1999 and March 2013, including 494 with femoral fractures, 572 with humeral fractures, and 638 with tibial fractures. Among them, 634 patients were followed up for more than 1 year. The operative time, intraoperative blood loss, postoperative complications, healing rate, and the excellent and good rate of functional recovery were compared between two groups. Compared with IIN group, RSIN group exhibited significantly shorter operative time and less intraoperative blood loss no matter for humeral, femoral, or tibial fractures (all p < 0.001). The healing rate in patients with more than 1 year follow-up was significantly higher in RSIN group for femoral and tibial fractures (both p < 0.05). In RSIN group, no nail breakage or loosening occurred, but radial nerve injury and incision infection were respectively observed in one patient with humeral fracture. In IIN group, nail breakage or loosening occurred in 7 patients with femoral fractures and 16 patients with tibial fractures, radial nerve injury was observed in 8 patients with humeral fractures, and incision infection was present in 2 patients with humeral fractures and 1 patient with femoral fracture. The complication rate of IIN group was significantly higher than that of RSIN group (p < 0.05). However, there were no significant differences in the excellent and good rate of shoulder, elbow, knee, and ankle joint functional recovery between RSIN group and IIN group. RSIN may be a reliable and practical alternative method for the treatment of long bone fractures.

  5. Interlocking intramedullary nailing in distal tibial fractures.

    PubMed

    Tyllianakis, M; Megas, P; Giannikas, D; Lambiris, E

    2000-08-01

    This retrospective study examined the results of non-pilon fractures of the distal part of the tibia treated with interlocking intramedullary nailing. Seventy-three patients with equal numbers of fractures treated surgically between 1990 and 1998 were reviewed. Mean patient age was 39.8 years, and follow-up averaged 34.2 months. The AO fracture classification system was used. Concomitant fractures of the lateral malleolus were fixed. All but three fractures achieved union within 4.2 months on average. Satisfactory or excellent results were obtained in 86.3% of patients. These results indicate interlocking intramedullary nailing is a reliable method of treatment for these fractures and is characterized by high rates of union and a low incidence of complications.

  6. An Innovative Approach to the Repair of Distal Tibia Nonunion Using a Retrograde Buried Tibio-Talar-Calcaneal Nail: A Case Report.

    PubMed

    Van Steyn, Peter; Romash, Michael

    We report a case using retrograde tibial nailing as treatment of nonunion of a distal tibial osteotomy, which was performed as part of a complex reconstruction of distal tibial malunion with ankle arthritis. Although retrograde nailing has classically been used for tibial-talar-calcaneal arthrodesis, this method spares the subtalar joint. Preservation of some hindfoot motion by subtalar mobility allows for a decrease in the loss of function typically seen with tibial-talar-calcaneal arthrodesis. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  7. Minimally invasive surgical technique: Percutaneous external fixation combined with titanium elastic nails for selective treatment of tibial fractures.

    PubMed

    Tu, Kai-Kai; Zhou, Xian-Ting; Tao, Zhou-Shan; Chen, Wei-Kai; Huang, Zheng-Liang; Sun, Tao; Zhou, Qiang; Yang, Lei

    2015-12-01

    Several techniques have been described to treat tibial fractures, which respectively remains defects. This article presents a novel intra- and extramedullary fixation technique: percutaneous external fixator combined with titanium elastic nails (EF-TENs system). The purpose of this study is to introduce this new minimally invasive surgical technique and selective treatment of tibial fractures, particularly in segmental fractures, diaphysis fractures accompanied with distal or proximal bone subfissure, or fractures with poor soft-tissue problems. Following ethical approval, thirty-two patients with tibial fractures were treated by the EF-TENs system between January 2010 and December 2012. The follow-up studies included clinical and radiographic examinations. All relevant outcomes were recorded during follow-up. All thirty-two patients were achieved follow-ups. According to the AO classification, 3 Type A, 9 Type B and 20 Type C fractures were included respectively. According to the Anderson-Gustilo classification, there were 5 Type Grade II, 3 Type Grade IIIA and 2 Type Grade IIIB. Among 32 patients, 8 of them were segmental fractures. 12 fractures accompanied with bone subfissure. Results showed no nonunion case, with an average time of 23.7 weeks (range, 14-32 weeks). Among them, there were 3/32 delayed union patients and 0/32 malunion case. 4/32 patients developed a pin track infection and no patient suffered deep infection. The external fixator was removed with a mean time of 16.7 weeks (range, 10-26 weeks). Moreover, only 1/32 patient suffered with the restricted ROM of ankle, none with the restricted ROM of knee. This preliminary study indicated that the EF-TENs system, as a novel intra- and extramedullary fixation technique, had substantial effects on selective treatment of tibial fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Knee arthodesis using a modular customized intramedullary nail.

    PubMed

    Letartre, R; Combes, A; Autissier, G; Bonnevialle, N; Gougeon, F

    2009-11-01

    Arthrodesis of the knee, particularly in infectious situations, can be achieved using either an external fixator or an intramedullary device. The objective of this study is to report the clinical, functional, and radiographic outcomes of a continuous series of 19 cases of knee arthrodesis using a customized modular intramedullary nailing system. The modular intramedullary nail offers a satisfactory functional result while maintaining limb length, in spite of a nonunion risk, since acting like a true endoprosthesis. In our retrospective series of 19 patients, the main source of patients were infected total knee replacements. The nail was customized from assembling a dual surface-sanded titanium component (femoral and tibial). The Lequesne Algofunctional score and the WOMAC score were recorded, as well as the length discrepancy between the lower extremities. Arthrodesis consolidation and the nail's fit in the shaft were verified on anterior-posterior (AP) and lateral radiographs. Five complications were observed: one anterior cortical break, one excessive tibial rotation, two cases of delayed union, and one nail revision due to residual nail instability. The postoperative Lequesne Algofunctional score was 13/24 and the WOMAC score 57/100. The nonunion rate was 32%. From a functional point of view, the patients who did not achieve complete union and those who did had similar scores. The subjective results were not as good in patients who did not achieve final consolidation. Modular intramedullary nailing simplifies the technique, shortens the procedure, and reduces the amount of blood loss at surgery. Our nonunion rate was high, although the functional result did not seem compromised by such nonunion. The risk of long-term implant failure was not studied and requires longer follow-up studies. Level IV therapeutic study. 2009 Published by Elsevier Masson SAS.

  9. Influence of knee flexion and atraumatic mobilisation of infrapatellar fat pad on incidence and severity of anterior knee pain after tibial nailing.

    PubMed

    Jankovic, Andrija; Korac, Zelimir; Bozic, Nenad-Bozo; Stedul, Ivan

    2013-09-01

    We evaluated the incidence and aetiology of anterior knee pain (AKP) in a series of patients that underwent intramedullary nailing for stabilisation of tibial fractures. During the preparation of the entry site no excision of the infrapatellar fat was allowed and electrical haemostasis was kept at the lowest level. Medullary canal was reamed and the nails inserted in position of knee flexion over 100 degrees. All fractures were fixed using medial paratendinous approach. Functional outcome was measured using Lysholm knee score. The knee range of movement and return to previous level of activity were also documented and analysed. Mean follow up was 38.9 months (range 12-84 months). In total 60 patients with 62 tibial shaft fractures were analysed. The mean age at the time of final follow up was 49.4 years (range 20-87). In 22 (35.5%) a newly developed and persisting pain in the anterior region of the operated knee was reported. According to VAP scale, the pain was mild (VAS 1-3) in 12 cases (19.4%) and moderate (VAS 4-6) in 10 (16.1%). In 16 cases (73%) the pain was noticed 6-12 months after injury and subjectively related to return to full range of working and recreational activities. The mean Lysholm knee score in the group without AKP was 90.8. In the AKP group with mild pain it was 88.4 and in the group with moderate AKP it was 79.9. Complete return to previous professional and recreational activities occurred in 49/60 patients (81.7%). Content with the treatment regarding expectations in recovery dynamics and return to desired level of activity was present in 98.3% of patients; one patient was unsatisfied with the treatment. Our results indicate that respecting the physiological motion of Hoffa pad and menisci during knee flexion, accompanied with atraumatic mobilisation of retrotendinous fat, reduces incidence and severity of anterior knee pain following intramedullary fixation of tibial shaft fractures. Copyright © 2013 Elsevier Ltd. All rights reserved.

  10. Fractures above and below a modular nail for knee arthrodesis. A case report.

    PubMed

    Hinarejos, Pedro; Ginés, Alberto; Monllau, Juan C; Puig, Lluis; Cáceres, Enric

    2005-06-01

    Several techniques have been advocated for knee arthrodesis, and there has been an increasing interest in modular intramedullary nails in the recent last years. We report a case of femoral and tibial fractures at each end of a modular nail in a solidly fused knee 8 months after an arthrodesis.

  11. Exchange nailing for nonunion of diaphyseal fractures of the tibia: our results and an analysis of the risk factors for failure.

    PubMed

    Tsang, S T J; Mills, L A; Frantzias, J; Baren, J P; Keating, J F; Simpson, A H R W

    2016-04-01

    The aim of this study was to identify risk factors for the failure of exchange nailing in nonunion of tibial diaphyseal fractures. A cohort of 102 tibial diaphyseal nonunions in 101 patients with a mean age of 36.9 years (15 to 74) were treated between January 1992 and December 2012 by exchange nailing. Of which 33 (32%) were initially open injuries. The median time from primary fixation to exchange nailing was 6.5 months (interquartile range (IQR) 4.3 to 9.8 months). The main outcome measures were union, number of secondary fixation procedures required to achieve union and time to union. Univariate analysis and multiple regression were used to identify risk factors for failure to achieve union. Multiple causes for the primary nonunion were found for 28 (27%) tibiae, with infection present in 32 (31%). Six patients were lost to follow-up. Further surgical procedures were required in 35 (36%) nonunions. Other fixation modalities were required in five fractures. A single nail exchange procedure achieved union in 60/96 (63%) of all nonunions. Only 11 out of 31 infected nonunions (35.4%) healed after one exchange nail procedure. Up to five repeated exchange nailings, with or without bone grafting, ultimately achieved union in 89 (93%) fractures. The median time to union after exchange nailing was 8.7 months (IQR 5.7 to 14.0 months). Univariate analysis confirmed that an oligotrophic/atrophic pattern of nonunion (p = 0.002), a bone gap of 5 mm or more (p = 0.04) and infection (p < 0.001), were predictive for failure of exchange nailing Multiple regression analysis found that infection was the strongest predictor of failure (p < 0.001). Exchange nailing is an effective treatment for aseptic tibial diaphyseal nonunion. However, in the presence of severe infection with a highly resistant organism, or extensive sclerosis of the bone, other fixation modalities, such as Ilizarov treatment, should be considered. Exchange nailing is an effective treatment for aseptic tibial

  12. Is there a bone-nail specific entry point? Automated fit quantification of tibial nail designs during the insertion for six different nail entry points.

    PubMed

    Amarathunga, J P; Schuetz, M A; Yarlagadda, K V D; Schmutz, B

    2015-04-01

    Intramedullary nailing is the standard fixation method for displaced diaphyseal fractures of tibia. Selection of the correct nail insertion point is important for axial alignment of bone fragments and to avoid iatrogenic fractures. However, the standard entry point (SEP) may not always optimise the bone-nail fit due to geometric variations of bones. This study aimed to investigate the optimal entry for a given bone-nail pair using the fit quantification software tool previously developed by the authors. The misfit was quantified for 20 bones with two nail designs (ETN and ETN-Proximal Bend) related to the SEP and 5 entry points which were 5 mm and 10 mm away from the SEP. The SEP was the optimal entry point for 50% of the bones used. For the remaining bones, the optimal entry point was located 5 mm away from the SEP, which improved the overall fit by 40% on average. However, entry points 10 mm away from the SEP doubled the misfit. The optimised bone-nail fit can be achieved through the SEP and within the range of a 5 mm radius, except posteriorly. The study results suggest that the optimal entry point should be selected by considering the fit during insertion and not only at the final position. Copyright © 2015 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. Finite Element Analysis of Absorbable Sheath to Prevent Stress Shielding of Tibial Interlocking Intramedullary Nail

    NASA Astrophysics Data System (ADS)

    Dong, Yansheng; Wang, Yongqing; Dong, Limin; Jia, Peng; Lu, Fengcheng

    2017-07-01

    The nail with absorbable sheath (AS nail) is designed to reduce the stress shielding effect of internal fixation with interlocking intramedullary nail. In order to verify its feasibility, two types of the finite element models of internal fixation of tibia with the AS nail and the common metal nail (CM nail) are established using the Softwares of Mimics, Geomagic, SolidWorks and ANSYS according to the CT scanning data of tibia. The result of the finite element analysis shows that the AS nail has great advantages compared with the CM nail in reducing the stress shielding effect in different periods of fracture healing. The conclusion is that the AS nail can realize the static fixation to the dynamic fixation from the early to the later automatically to shorten the time of fracture healing, which also provides a new technique to the interlocking intramedullary nail.

  14. Comparison of two intramedullary nails for tibiotalocalcaneal fusion: anatomic and radiographic considerations.

    PubMed

    Mückley, Thomas; Ullm, Sebastian; Petrovitch, Alexander; Klos, Kajetan; Beimel, Claudia; Fröber, Rosemarie; Hofmann, Gunther O

    2007-05-01

    Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. This study was conducted to see whether, and if so to what extent, nail design modifications would influence the risk to anatomic structures and the bony coverage of the nail base. Six pairs of thawed fresh-frozen cadaver legs received two different intramedullary nails (N1: straight nail, lateral-medial tip locking; N2: valgus-curved nail, medial-lateral tip locking) under simulated operative conditions. The specimens were dissected; distances between the at-risk structures and the hardware were measured. The hindfoot axis and the volume of the intracalcaneal nail portion were determined with CT. At the plantar entry site, N2 was significantly farther from the flexor hallucis longus tendon (p=0.047), the medial plantar artery (p=0.026), and the lateral plantar nerve (p=0.026) than N1. The lateral-medial calcaneal locking screw of N1 damaged significantly more often the peroneus brevis tendon (p=0.03) than N2. The proximal tip-locking screw, N2, was significantly farther from the anterior tibial artery (p=0.075) and the deep (p=0.047) and superficial peroneal nerves (p=0.009) than N1; N1 was significantly farther from the great saphenous vein (p=0.075) than N2. The distal tip-locking screw, N1. damaged significantly more often the extensor digitorum longus (p=0.007), the anterior tibial artery(p = 0.04), and the deep and superficial peroneal nerves (p=0.03) than N2. CT did not show any significant changes in the hindfoot axis with either device; intracalcaneal nail volumes were similar. A curved nail can increase the distance to at-risk plantar structures. Medial-lateral nail-tip locking appears to have less risk to neurovascular structures. Safer retrograde intramedullary nailing for tibiotalocalcaneal fusion requires knowledge of the structures at risk and appropriate operative technique.

  15. Surgical treatment of refractory tibial stress fractures in elite dancers: a case series.

    PubMed

    Miyamoto, Ryan G; Dhotar, Herman S; Rose, Donald J; Egol, Kenneth

    2009-06-01

    Treatment of tibial stress fractures in elite dancers is centered on rest and activity modification. Surgical intervention in refractory cases has important implications affecting the dancers' careers. Refractory tibial stress fractures in dancers can be treated successfully with drilling and bone grafting or intramedullary nailing. Case series; Level of evidence, 4. Between 1992 and 2006, 1757 dancers were evaluated at a dance medicine clinic; 24 dancers (1.4%) had 31 tibial stress fractures. Of that subset, 7 (29.2%) elite dancers with 8 tibial stress fractures were treated operatively with either intramedullary nailing or drilling and bone grafting. Six of the patients were followed up closely until they were able to return to dance. One patient was available only for follow-up phone interview. Data concerning their preoperative treatment regimens, operative procedures, clinical union, radiographic union, and time until return to dance were recorded and analyzed. The mean age of the surgical patients at the time of stress fracture was 22.6 years. The mean duration of preoperative symptoms before surgical intervention was 25.8 months. Four of the dancers were male and 3 were female. All had failed nonoperative treatment regimens. Five patients (5 tibias) underwent drilling and bone grafting of the lesion, and 2 patients (3 tibias) with completed fractures or multiple refractory stress fractures underwent intramedullary nailing. Clinical union was achieved at a mean of 6 weeks and radiographic union at 5.1 months. Return to full dance activity was at an average of 6.5 months postoperatively. Surgical intervention for tibial stress fractures in dancers who have not responded to nonoperative management allowed for resolution of symptoms and return to dancing with minimal morbidity.

  16. Primary Ankle Arthrodesis for Severely Comminuted Tibial Pilon Fractures.

    PubMed

    Al-Ashhab, Mohamed E

    2017-03-01

    Management of severely comminuted, complete articular tibial pilon fractures (Rüedi and Allgöwer type III) remains a challenge, with few treatment options providing good clinical outcomes. Twenty patients with severely comminuted tibial pilon fractures underwent primary ankle arthrodesis with a retrograde calcaneal nail and autogenous fibular bone graft. The fusion rate was 100% and the varus malunion rate was 10%. Fracture union occurred at a mean of 16 weeks (range, 13-18 weeks) postoperatively. Primary ankle arthrodesis is a successful method for treating highly comminuted tibial pilon fractures, having a low complication rate and a high satisfaction score. [Orthopedics. 2017; 40(2):e378-e381.]. Copyright 2016, SLACK Incorporated.

  17. Reducing intraoperative duration and ionising radiation exposure during the insertion of distal locking screws of intramedullary nails: a small-scale study comparing the current fluoroscopic method against radiation-free, electromagnetic navigation.

    PubMed

    Grimwood, Darren; Harvey-Lloyd, Jane

    2016-12-01

    Intramedullary nailing is the standard surgical treatment for mid-diaphyseal fractures of long bones; however, it is also a high radiation dose procedure. Distal locking is regularly cited as a demanding element of the procedure, and there remains a reliance on X-ray fluoroscopy to locate the distal holes. A recently developed electromagnetic navigation (EMN) system allows radiation-free distal locking, with a virtual on-screen image. To compare operative duration, fluoroscopy time and radiation dose when using EMN over fluoroscopy, for the distal locking of intramedullary nails. Consecutive patients with mid-diaphyseal fractures of the tibia and femur, treatable with intramedullary nails, were prospectively enrolled during a 9-month period. The sample consisted of 29 individuals, 19 under fluoroscopic guidance and 10 utilising EMN. Participants were allocated depending on the type of intramedullary nail used and surgeon's preference. These were further divided into tibial and femoral subcategories, relative to the fracture site. EMN reduced fluoroscopy time by 49 (p = 0.038) and 28 s during tibial and femoral nailings, respectively. Radiation dose was reduced by 18 cGy/cm 2 (p = 0.046) during tibial and 181 cGy/cm 2 during femoral nailings when utilising EMN. Operative duration was 11 min slower during tibial nailings using EMN, but 38 min faster in respect of femoral nailings. This study has evidenced statistically significant reductions in both fluoroscopy time and radiation dose when using EMN for the distal locking of intramedullary nails. It is expected that overall operative duration would also decrease in line with similar studies, with increased usage and a larger sample.

  18. Tension Band Plating for Chronic Anterior Tibial Stress Fractures in High-Performance Athletes.

    PubMed

    Zbeda, Robert M; Sculco, Peter K; Urch, Ekaterina Y; Lazaro, Lionel E; Borens, Olivier; Williams, Riley J; Lorich, Dean G; Wellman, David S; Helfet, David L

    2015-07-01

    Anterior tibial stress fractures are associated with high rates of delayed union and nonunion, which can be particularly devastating to a professional athlete who requires rapid return to competition. Current surgical treatment strategies include intramedullary nailing, which has satisfactory rates of fracture union but an associated risk of anterior knee pain. Anterior tension band plating is a biomechanically sound alternative treatment for these fractures. Tension band plating of chronic anterior tibial stress fractures leads to rapid healing and return to physical activity and avoids the anterior knee pain associated with intramedullary nailing. Case series; Level of evidence, 4. Between 2001 and 2013, there were 13 chronic anterior tibial stress fractures in 12 professional or collegiate athletes who underwent tension band plating after failing nonoperative management. Patient charts were retrospectively reviewed for demographics, injury history, and surgical details. Radiographs were used to assess time to osseous union. Follow-up notes and phone interviews were used to determine follow-up time, return to training time, and whether the patient was able to return to competition. Cases included 13 stress fractures in 12 patients (9 females, 3 males). Five patients were track-and-field athletes, 4 patients played basketball, 2 patients played volleyball, and 1 was a ballet dancer. Five patients were Division I collegiate athletes and 7 were professional or Olympic athletes. Average age at time of surgery was 23.6 years (range, 20-32 years). Osseous union occurred on average at 9.6 weeks (range, 5.3-16.9 weeks) after surgery. Patients returned to training on average at 11.1 weeks (range, 5.7-20 weeks). Ninety-two percent (12/13) eventually returned to preinjury competition levels. Thirty-eight percent (5/13) underwent removal of hardware for plate prominence. There was no incidence of infection or nonunion. Anterior tension band plating for chronic tibial stress

  19. Ruptured Pseudoaneurysm of the Lateral Plantar Artery After Tibiotalocalcaneal Fusion With Retrograde Nail-A Rare Complication.

    PubMed

    Sundararajan, Silvampatti Ramaswamy; Rajagopalakrishnan, Ramakanth; Rajasekaran, Shanmuganathan

    We report a rare presentation of a ruptured pseudoaneurysm of the lateral plantar artery following tibiotalocalcaneal fusion with a retrograde nail at 1 month after the index surgery. Although case reports of pseudoaneurysms of larger arteries such as the anterior tibial artery and posterior tibial artery after ankle surgery (e.g., ankle arthroscopy, implant removal, Ilizarov application) have been reported, we report a rare complication of a pseudoaneurysm of the lateral plantar artery. We discuss the anatomic considerations of the lateral plantar artery in the foot and the entry point of the retrograde nail to avoid this unusual complication. Copyright © 2017 The American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  20. In vivo biomechanical evaluation of a novel angle-stable interlocking nail design in a canine tibial fracture model.

    PubMed

    Déjardin, Loïc M; Cabassu, Julien B; Guillou, Reunan P; Villwock, Mark; Guiot, Laurent P; Haut, Roger C

    2014-03-01

    To compare clinical outcome and callus biomechanical properties of a novel angle stable interlocking nail (AS-ILN) and a 6 mm bolted standard ILN (ILN6b) in a canine tibial fracture model. Experimental in vivo study. Purpose-bred hounds (n = 11). A 5 mm mid-diaphyseal tibial ostectomy was stabilized with an AS-ILN (n = 6) or an ILN6b (n = 5). Orthopedic examinations and radiographs were performed every other week until clinical union (18 weeks). Paired tibiae were tested in torsion until failure. Callus torsional strength and toughness were statistically compared and failure mode described. Total and cortical callus volumes were computed and statistically compared from CT slices of the original ostectomy gap. Statistical significance was set at P < .05 RESULTS: From 4 to 8 weeks, lameness was less pronounced in AS-ILN than ILN6b dogs (P < .05). Clinical union was reached in all AS-ILN dogs by 10 weeks and in 3/5 ILN6b dogs at 18 weeks. Callus mechanical properties were significantly greater in AS-ILN than ILN6b specimens by 77% (failure torque) and 166% (toughness). Failure occurred by acute spiral (control and AS-ILN) or progressive transverse fractures (ILN6b). Cortical callus volume was 111% greater in AS-ILN than ILN6b specimens (P < .05). Earlier functional recovery, callus strength and remodeling suggest that the AS-ILN provides a postoperative biomechanical environment more conducive to bone healing than a comparable standard ILN. © Copyright 2014 by The American College of Veterinary Surgeons.

  1. Tension band plating of a nonunion anterior tibial stress fracture in an athlete.

    PubMed

    Merriman, Jarrad A; Villacis, Diego; Kephart, Curtis J; Rick Hatch, George F

    2013-07-01

    The authors present a rare technique of tension band plating of the anterior tibia in the setting of a nonunion stress fracture. Surgical management with an intramedullary nail is a viable and proven option for treating such injuries. However, in treating elite athletes, legitimate concerns exist regarding the surgical disruption of the extensor mechanism and the risk of anterior knee pain associated with intramedullary nail use. The described surgical technique demonstrates the use of tension band plating as an effective treatment of delayed union and nonunion anterior tibial stress fractures in athletes without the potential risks of intramedullary nail insertion. Copyright 2013, SLACK Incorporated.

  2. The influence of distal locking on the need for fibular plating in intramedullary nailing of distal metaphyseal tibiofibular fractures.

    PubMed

    Attal, R; Maestri, V; Doshi, H K; Onder, U; Smekal, V; Blauth, M; Schmoelz, W

    2014-03-01

    Using human cadaver specimens, we investigated the role of supplementary fibular plating in the treatment of distal tibial fractures using an intramedullary nail. Fibular plating is thought to improve stability in these situations, but has been reported to have increased soft-tissue complications and to impair union of the fracture. We proposed that multidirectional locking screws provide adequate stability, making additional fibular plating unnecessary. A distal tibiofibular osteotomy model performed on matched fresh-frozen lower limb specimens was stabilised with reamed nails using conventional biplanar distal locking (CDL) or multidirectional distal locking (MDL) options with and without fibular plating. Rotational stiffness was assessed under a constant axial force of 150 N and a superimposed torque of ± 5 Nm. Total movement, and neutral zone and fracture gap movement were analysed. In the CDL group, fibular plating improved stiffness at the tibial fracture site, albeit to a small degree (p = 0.013). In the MDL group additional fibular plating did not increase the stiffness. The MDL nail without fibular plating was significantly more stable than the CDL nail with an additional fibular plate (p = 0.008). These findings suggest that additional fibular plating does not improve stability if a multidirectional distal locking intramedullary nail is used, and is therefore unnecessary if not needed to aid reduction.

  3. Novel management of distal tibial and fibular fractures with Acumed fibular nail and minimally invasive plating osteosynthesis technique: A case report.

    PubMed

    Wang, Tie-Jun; Ju, Wei-Na; Qi, Bao-Chang

    2017-03-01

    Anatomical characteristics, such as subcutaneous position and minimal muscle cover, contribute to the complexity of fractures of the distal third of the tibia and fibula. Severe damage to soft tissue and instability ensure high risk of delayed bone union and wound complications such as nonunion, infection, and necrosis. This case report discusses management in a 54-year-old woman who sustained fractures of the distal third of the left tibia and fibula, with damage to overlying soft tissue (swelling and blisters). Plating is accepted as the first choice for this type of fracture as it ensures accurate reduction and rigid fixation, but it increases the risk of complications. Closed fracture of the distal third of the left tibia and fibula (AO: 43-A3). After the swelling was alleviated, the patient underwent closed reduction and fixation with an Acumed fibular nail and minimally invasive plating osteosynthesis (MIPO), ensuring a smaller incision and minimal soft-tissue dissection. At the 1-year follow-up, the patient had recovered well and had regained satisfactory function in the treated limb. The Kofoed score of the left ankle was 95. Based on the experience from this case, the operation can be undertaken safely when the swelling has been alleviated. The minimal invasive technique represents the best approach. Considering the merits and good outcome in this case, we recommend the Acumed fibular nail and MIPO technique for treatment of distal tibial and fibular fractures.

  4. A prospective multi-center study of intramedullary nailing vs casting of stable tibial shaft fractures.

    PubMed

    Obremskey, William T; Cutrera, Norele; Kidd, Christopher M

    2017-03-01

    The purpose of this study was to determine optimal treatment of stable tibial shaft fractures using intramedullary nailing (IMN) or casting. We performed a multi-center prospective study cohort. Patients with stable tibia shaft fractures meeting Sarmiento's criteria (isolated closed fractures with less than 12 mm of shortening and 10° of angulation) were enrolled prospectively and treated with either a reamed IMN with static interlocking screws or closed reduction followed by long-leg casting. Both groups were weight bearing following surgery. Radiographs were taken until union, and range of motion of knee and ankle joints was assessed. Malalignment (>5°) and malunion (>10°) were determined. Functional outcome measures using short musculoskeletal assessment scores (SMFA) and a knee pain score were scheduled at 6 weeks, 3 months and 6 months. At 3 months, differences between the casting and IMN groups were noted in return to work (6/15 vs 3/17, P < 0.05); ankle dorsiflexion (7° vs 12°, P < 0.05); plantar flexion (28° vs 39°, P < 0.05); and SMFA domains of Dysfunction Index, Bother Index, daily activities, emotional status, and arm/hand function (P < 0.05). The SMFA mobility function demonstrated a significant trend (P = 0.065). At 6 months, malalignment was present in 3/15 in the casting group and in 1/17 in the IMN group (P = 0.02). Malunion was present in 1/15 in the cast group. One fracture in the casting group went on to nonunion and required late IMN placement at 7 months and eventually healed. There were no differences in ankle motion, SMFA scores, or return to work. There was no difference in knee pain between the groups as measured by VAS and Court-Brown pain scale at 6 months. Patients with stable tibia fractures treated with intramedullary nailing have improved clinical and functional outcomes at 3 months compared with those treated with casting, but there are no differences in any other outcome measure. Patients treated in a

  5. Management of Open Tibial Shaft Fractures: Does the Timing of Surgery Affect Outcomes?

    PubMed

    Duyos, Oscar A; Beaton-Comulada, David; Davila-Parrilla, Ariel; Perez-Lopez, Jose Carlos; Ortiz, Krystal; Foy-Parrilla, Christian; Lopez-Gonzalez, Francisco

    2017-03-01

    Open tibial shaft fractures require emergent care. Treatment with intravenous antibiotics and fracture débridement within 6 to 24 hours is recommended. Few studies have examined outcomes when surgical treatment is performed >24 hours after occurrence of the fracture. This retrospective study included 227 patients aged ≥18 years with isolated open tibial shaft fractures in whom the time to initial débridement was >24 hours. The statistical analysis was based on time from injury to surgical débridement, Gustilo-Anderson classification, method of fixation, union status, and infection status. Fractures débrided within 24 to 48 hours and 48 to 96 hours after injury did not show a statistically significant difference in terms of infection rates (P = 0.984). External fixation showed significantly greater infection rates (P = 0.044) and nonunion rates (P = 0.001) compared with intramedullary nailing. Open tibial shaft fractures should be débrided within 24 hours after injury. Our data indicate that after the 24-hour period and up to 4 days, the risk of infection remains relatively constant independent of the time to débridement. Patients treated with external fixation had more complications than did patients treated with other methods of fixation. Primary reamed intramedullary nailing appears to be a reasonable option for the management of Gustilo-Anderson types 1 and 2 open tibial shaft fractures. Level III retrospective study.

  6. Intramedullary nailing versus plating for extra-articular distal tibial metaphyseal fracture: a systematic review and meta-analysis.

    PubMed

    Xue, Xing-He; Yan, Shi-Gui; Cai, Xun-Zi; Shi, Ming-Min; Lin, Tiao

    2014-04-01

    With development in the techniques of reduction and fixation, there has been a controversy in comparison between intramedullary nailing (IMN) and plating for the treatment of distal tibial metaphyseal fracture (DTF). The study aimed to investigate: (1) which fixation, IMN or plating, was better in the clinical outcomes and in the complications for the treatment of DTF and (2) which modifying variables affected the comparative results between the two modalities. PubMed, EMBASE, OVID, Scopus, ISI Web of Science, the Cochrane Library, Google Scholar and specific orthopaedic journals were searched from inception to July 2013, using the search strategy of '('Fracture Fixation, Intramedullary' [MeSH]) AND ('Tibial Fractures' [MeSH]) AND (plate OR plating)'. All prospective and retrospective controlled trials comparing function, pain, bone union and complications between IMN and plating for DTF were identified. Our analysis had no limitation of the language or the publication year. The primary outcome measurements were complication rate, union time, operation time and hospital stays, while the secondary outcome measurements were functional score and pain score. Fourteen of 6620 studies with 842 patients were included. IMN was probably preferential to plating for DTF given its higher functional score (p=0.01), lower risk of infection (p=0.02) and comparable pain score (p=0.33), total complication rate (p=0.53) and time to union (p=0.86). However, plating had a lower malunion rate than IMN (p<0.0001). All the results were based on the Grading of Recommendations Assessment, Development and Evaluation (GRADE) evidence of moderate quality. With a satisfying alignment obtained, IMN may be preferential to plating for fixation of DTF with better function and lower risk of infection. However, IMN showed higher malunion rate for fixation of DTF. With the biases in our meta-analysis, it will ultimately require a rigorous and adequately powered randomised controlled trial (RCT) to

  7. [Tibiocalcaneal arthrodesis using retrograde insertion of a compression nail].

    PubMed

    Bölderl, A; Dallapozza, C; Wille, M

    2011-12-01

    OPERATION GOAL: Arthrodesis of the upper and lower ankle joint because of problematic bone positioning or failed arthrodesis. Osteosynthesis procedure using a retrograde compression nail. To achieve stable, fully weight-bearing osteosynthesis for early, pain-free mobilization. Rearthrodesis because of failure of the conventional arthrodesis technique and development of osteoarthritis of the lower ankle joint. Painful osteoarthritis of the upper ankle joint because of inadequate perfusion or a major bone defect because of sclerosis or necrosis. Primary arthrodesis because of facture of the lower leg (pilon tibial) with joint involvement and preexisting osteoarthritis. Acute osteitis/osteomyelitis, sclerosis in the marrow of the distal tibia, malalignment of the distal tibial shaft and local soft tissue inflammation. Preparation of the articular surface of the upper and lower ankle for arthrodesis using a transfibular approach. If necessary, correction of bone defects with iliac crest spongiosa. Stabile osteosynthesis by retrograde insertion of a compression nail. A split lower leg cast on the 2nd postoperative day, mobilization of the patient with underarm crutches with floor contact for 2 weeks, then with application of a lower leg walking cast for 8 weeks with partial weight-bearing for 4 weeks and full weight-bearing for the last 4 weeks of cast fixation. X-ray controls immediately postoperatively, then after 6 and 12 weeks. From 2006 to 2008, 12 patients (7 men, 5 women; mean age 59 years) with various indications were treated with retrograde insertion of a compression nail. All patients were routinely controlled radiologically and clinically after 2, 4, 8 and 12 weeks. Follow-up was carried out at 6, 12 and 24 months. All arthrodeses showed osseous consolidation 16 weeks postoperatively. Ten patients were able to use full weight-bearing without pain after 12 weeks. Two patients reported experiencing pain after walking for 2 h. In total three

  8. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study

    PubMed Central

    Eisenstein, Emmanuel D.; Rodriguez, Mario

    2016-01-01

    Introduction. Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods. We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results. Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion. Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice. PMID:27818800

  9. New Technique for Tibiotalar Arthrodesis Using a New Intramedullary Nail Device: A Cadaveric Study.

    PubMed

    Eisenstein, Emmanuel D; Rodriguez, Mario; Abdelgawad, Amr A

    2016-01-01

    Introduction . Ankle arthrodesis is performed in a variety of methods. We propose a new technique for tibiotalar arthrodesis using a newly designed intramedullary nail. Methods . We proposed development of an intramedullary device for ankle arthrodesis which spared the subtalar joint using a sinus tarsi approach. Standard saw bones models and computer assisted modeling and stress analysis were used to develop different nail design geometries and determine the feasibility of insertion. After the final design was constructed, the device was tested on three cadaveric specimens. Results . Four basic nail geometries were developed. The optimal design was composed of two relatively straight segments, each with a different radius of curvature for their respective tibial and talar component. We successfully implemented this design into three cadaveric specimens. Conclusion . Our newly designed tibiotalar nail provides a new technique for isolated tibiotalar fusion. It utilizes the advantages of a tibiotalar calcaneal nail and spares the subtalar joint. This design serves as the foundation for future research to include compression options across the tibiotalar joint and eventual transition to clinical practice.

  10. Elastic nailing of tibia shaft fractures in young children up to 10 years of age.

    PubMed

    Heo, Jeong; Oh, Chang-Wug; Park, Kyeong-Hyeon; Kim, Joon-Woo; Kim, Hee-June; Lee, Jong-Chul; Park, Il-Hyung

    2016-04-01

    Although tibia shaft fractures in children usually have satisfactory results after closed reduction and casting, there are several surgical indications, including associated fractures and soft tissue injuries such as open fractures. Titanium elastic nails (TENs) are often used for pediatric tibia fractures, and have the advantage of preserving the open physis. However, complications such as delayed union or nonunion are not uncommon in older children or open fractures. In the present study, we evaluated children up to 10 years of age with closed or open tibial shaft fractures treated with elastic nailing technique. A total of 16 tibia shaft fractures treated by elastic nailing from 2001 to 2013 were reviewed. The mean patient age at operation was 7 years (range: 5-10 years). Thirteen of 16 cases were open fractures (grade I: 4, grade II: 6, grade IIIA: 3 cases); the other cases had associated fractures that necessitated operative treatments. Closed, antegrade intramedullary nailing was used to insert two nails through the proximal tibial metaphysis. All patients were followed up for at least one year after the injury. Outcomes were evaluated using modified Flynn's criteria, including union, alignment, leg length discrepancies, and complications. All fractures achieved union a mean of 16.1 weeks after surgery (range: 11-26 weeks). No patient reported knee pain or experienced any loss of knee or ankle motion. There was a case of superficial infection in a patient with grade III open fracture. Three patients reported soft tissue discomfort due to prominent TEN tips at the proximal insertion site, which required cutting the tip before union or removing the nail after union. At the last follow-up, there were no angular or rotational deformities over 10° in either the sagittal or coronal planes. With the exception of one case with an overgrowth of 15 mm, no patient showed shortening or overgrowth exceeding 10mm. Among final outcomes, 15 were excellent and 1 was

  11. [Knee arthrodesis using a customized intramedullary nail: 14 cases].

    PubMed

    Volpi, R; Dehoux, E; Touchard, P; Mensa, C; Segal, P

    2004-02-01

    We report our experience with knee arthrodesis using a customized intramedullary nail implanted in 14 patients. Indications for knee arthrodesis were: recurrent prosthesis infection (n=11), post-traumatic septic arthritis (n=1), aseptic loosening of a hinge prosthesis (n=1), and nonunion (n=1). A two-stage procedure was used for the 12 patients with infected joints. Mean follow-up was 19 months. Weight bearing began during the first week after arthrodesis in 13 patients. First intention bone healing was achieved in 13 patients. Mean time to healing was three months. All patients rapidly recovered full independence. Complications were: one misinsertion of the tibial stem, one nonunion which fused after repeated grafting, and two recurrent infections (controlled chronic fistulae) which required skin flaps for cover. We have found that this customized nail is a useful method for achieving bone fusion in patients with difficult indications for arthrodesis, particularly recurrent prosthesis infection.

  12. Rotary self-locking intramedullary nail for long tubular bone fractures.

    PubMed

    Huang, Zhong-lian; Yang, Hai-long; Xu, Jian-kun; Xia, Xue; Wang, Xin-jia; Song, Jian-xin; Hu, Jun

    2013-10-01

    Intramedullary nails had been widely used in the treatment of long-bone fractures because of less interference of fractures and center bearing biomechanical advantage. However, it had been also found many shortcomings such as broken nails, delayed healing and was modified in order to achieve better efficacy and reduce complications. The aim of the present study is to compare the efficacy of rotary self-locking intramedullary nails (RSIN) with that of interlocking intramedullary nails (IIN) in the treatment of long-bone fractures. A retrospective study investigated 129 cases with long-bone fractures (36 with femoral fracture, 81 with tibial fracture, and 12 with humeral fracture). The fractures were fixed using either an RSIN or IIN. All patients underwent followup for 12-30 months. All patients in both groups achieved a clinical fracture healing standard and the postoperative affected limb muscle strength and joint function were well restored. The RSIN group required a shorter operative time and the fracture healed faster. There was no significant difference in the hospital stay, intraoperative blood loss or postoperative complications between the two groups. RSIN is used to treat long-bone fractures. Its healing efficacy is equivalent to the IIN. Moreover, the RSIN method is simpler and causes less tissue damage than the IIN, therefore having the advantage of accelerated healing.

  13. Nail cosmetics.

    PubMed

    Madnani, Nina A; Khan, Kaleem J

    2012-01-01

    The nail as an anatomic structure protects the terminal phalanx of the digit from injury. Historically, it has served as a tool for protection and for survival. As civilizations developed, it attained the additional function of adornment. Nail beautification is a big industry today, with various nail cosmetics available, ranging from nail hardeners, polishes, extensions, artificial/sculpted nails, and nail decorations. Adverse events may occur either during the nail-grooming procedure or as a reaction to the individual components of the nail cosmetics. This holds true for both the client and the nail technician. Typically, any of the procedures involves several steps and a series of products. Separate "nail-bars" have been set up dedicated to serve women and men interested in nail beautification. This article attempts to comprehensively inform and educate the dermatologist on the services offered, the products used, and the possible/potential adverse effects related to nail-grooming and nail cosmetics.

  14. Limb Lengthening Using the PRECICETM Nail System: Complications and Results

    PubMed Central

    Wiebking, Ulrich; Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian

    2016-01-01

    Background Three types of telescopic nails are mainly used for intramedullary limb lengthening nowadays. Despite some important advantages of this new technology (e.g. controlled distraction rate, not restricted availability, possibility to perform accordion maneuvers), few articles exist on clinical results and complications after lengthening with the PRECICETM nail (Ellipse, USA). Objectives The aim of the current study was to describe and analyze the complications associated with lengthening with the PRECICETM nail. Are the problems preventable when using the PRECICE, related to the distraction rate control, the lengthening goals and technique and handling? Methods We retrospectively reviewed the charts of 9 patients operated between 2012 and 2013 with a PRECICETM nail for a leg length discrepancy (LLD). The mean age of the patients was 32 years (range, 17 - 48 years). There were 5 femoral and 4 tibial procedures. The causes of LLD were posttraumatic (n = 5) and congenital (n = 4). The mean LLD was 36.4 ± 11.4 mm. The minimum follow-ups were 2 months (average, 5 months; range, 2 - 9 months). Results The mean distraction rate was 0.5 ± 0.1 mm/day. We observed in 7 patients differences in achieving the lengthening goals (average, 1.6 mm; range, -20.0 - 5.0 mm). Average lengthening was 34.7 ± 10.7 mm. All patients reached normal alignment and normal joint orientation. An unintentional loss of the achieved length during the consolidation phase was noticed in patients with delayed bone healing in two cases. In the first case (loss of 20mm distraction) the nail could be redistracted and the goal length was achieved. In the second case (loss of 10mm distraction) the nail broke shortly after the diagnosis and the nail was exchanged. Conclusions We report of loss of achieved length after lengthening with a telescopic nail. Weight bearing before complete consolidation of the regenerate might be a risk factor for that. Thorough examination of the limb length and careful

  15. Tibial shaft fractures in football players

    PubMed Central

    Chang, Winston R; Kapasi, Zain; Daisley, Susan; Leach, William J

    2007-01-01

    Background Football is officially the most popular sport in the world. In the UK, 10% of the adult population play football at least once a year. Despite this, there are few papers in the literature on tibial diaphyseal fractures in this sporting group. In addition, conflicting views on the nature of this injury exist. The purpose of this paper is to compare our experience of tibial shaft football fractures with the little available literature and identify any similarities and differences. Methods and Results A retrospective study of all tibial football fractures that presented to a teaching hospital was undertaken over a 5 year period from 1997 to 2001. There were 244 tibial fractures treated. 24 (9.8%) of these were football related. All patients were male with a mean age of 23 years (range 15 to 29) and shin guards were worn in 95.8% of cases. 11/24 (45.8%) were treated conservatively, 11/24 (45.8%) by Grosse Kemp intramedullary nail and 2/24 (8.3%) with plating. A difference in union times was noted, conservative 19 weeks compared to operative group 23.9 weeks (p < 0.05). Return to activity was also different in the two groups, conservative 27.6 weeks versus operative 23.3 weeks (p < 0.05). The most common fracture pattern was AO Type 42A3 in 14/24 (58.3%). A high number 19/24 (79.2%) were simple transverse or short oblique fractures. There was a low non-union rate 1/24 (4.2%) and absence of any open injury in our series. Conclusion Our series compared similarly with the few reports available in the literature. However, a striking finding noted by the authors was a drop in the incidence of tibial shaft football fractures. It is likely that this is a reflection of recent compulsory FIFA regulations on shinguards as well as improvements in the design over the past decade since its introduction. PMID:17567522

  16. Prediction of a nail polish colour applied on a nail.

    PubMed

    Monpeurt, C; Cinotti, E; Razafindrakoto, J; Rubegni, P; Fimiani, M; Perrot, J L; Hebert, M

    2018-02-01

    The colour of a nail polish varies according to the nail on which it is applied. The objective of this study was to predict the colour of the nail polish on a given nail and to study how the colour varies depending on the nail polish thickness. Six nail polishes were applied in one, two and three layers on the nails of one subject, thus forming eighteen samples. The spectral reflectances of the eighteen nail polishes applied on the nails with different thicknesses were obtained by spectrophotometry. The spectral reflectances of the nails without polish were also measured using the same technique. The thicknesses of nail polishes were measured by high-definition optical coherence tomography (HD-OCT). Then, to determine the physical parameters of the nail polish itself, we applied the six nail polishes on an opacity drawdown chart and we measured the spectral reflectance and the thickness of each patch using spectrophotometry and HD-OCT, respectively. The Kubelka-Munk theory was used to get the predicted spectral reflectance of the nail polish applied on the nail according to the polish thickness by knowing the parameter of the polish itself and the spectral reflectance of the nail. The predicted spectral reflectances were finally compared with those measured directly on the nails. The predicted spectral reflectances were rather close to measured ones. Consequently, knowing the colour of the nail without polish and the optical parameters of the nail polish itself, we can estimate the colour of the nail polish applied on the nail depending on its thickness. Our study showed that the Kubelka-Munk theory can be used to predict the nail polish colour. The ability to predict the real colour of a nail polish applied on a nail could help a nail polish manufacturer to improve his polish formulae in order to obtain a precise colour. © 2017 Society of Cosmetic Scientists and the Société Française de Cosmétologie.

  17. Management of knee rheumatoid arthritis and tibia nonunion with one-stage total knee arthroplasty and intramedullary nailing: A report of two cases.

    PubMed

    Erdogan, Fahri; Sarikaya, Ilker Abdullah; Can, Ata; Gorgun, Baris

    2018-01-01

    Total knee arthroplasty (TKA) is a surgical procedure which is widely used in the treatment of gonarthrosis secondary to rheumatoid arthritis (RA). The incidence of stress fractures in tibia in the patients with RA is higher compared to normal patients. In this study, we report two cases of TKA and intramedullary nailing in RA patients with severe knee arthritis and tibial nonunion. Both patients had a satisfactory clinical outcome with radiological healing of the tibial fracture. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  18. Effect on dynamic mechanical stability and interfragmentary movement of angle-stable locking of intramedullary nails in unstable distal tibia fractures: a biomechanical study.

    PubMed

    Gueorguiev, Boyko; Wähnert, Dirk; Albrecht, Daniel; Ockert, Ben; Windolf, Markus; Schwieger, Karsten

    2011-02-01

    Unstable distal tibia fractures are challenging injuries that require surgery. Increasingly, intramedullary nails are being used. However, fracture site anatomy may cause distal-fragment stabilization and fixation problems and lead to malunion/nonunion. We studied the influence of angle-stable nail locking on fracture gap movement and other biomechanical parameters. Eight pairs of fresh human cadaver tibiae were used. The bone mineral density (BMD) was determined. All tibiae were nailed with a Synthes Expert tibial nail. Within each pair, one tibia was randomized to receive conventional locking screws; the other, angle-stable screws with sleeves. A 7-mm osteotomy was created 10 mm above the upper distal locking screw, to simulate an AO 42-A3 fracture. Biomechanical testing involved nondestructive mediolateral and anteroposterior pure bending, followed by cyclic combined axial and torsional loading to catastrophic failure. The neutral zone was determined. Fracture gap movement was monitored with 3-D motion tracking. The angle-stable locked constructs had a significantly smaller mediolateral neutral zone (mean: 0.04 degree; p=0.039) and significantly smaller fracture gap angulation (p=0.043). The number of cycles to failure did not differ significantly between the locking configurations. BMD was a significant covariate affecting the number of cycles to failure (p=0.008). However, over the first 20,000 cycles, there was no significant correlation in the angle-stable construct. Angle-stable locking of the Expert tibial nail was associated with a significant reduction in the mediolateral neutral zone and in fracture gap movement. Angle-stable fixation also reduced the influence of BMD over the first 20,000 cycles.

  19. Outcome of Distal Both Bone Leg Fractures Fixed by Intramedulary Nail for Fibula & MIPPO in Tibia.

    PubMed

    Gupta, Anil; Anjum, Rashid; Singh, Navdeep; Hackla, Shafiq

    2015-04-01

    Fractures of the distal third of the tibia are mostly associated with a fibular fracture that often requires fixation. The preferred treatment of distal tibial fracture is the minimally invasive percutaneous plate osteosynthesis (MIPPO) procedure. However, there are no clear cut guidelines on fixation of the fibular fracture and currently most orthopedic surgeons use a plate osteosynthesis for the fibula as well. A common complication associated with dual plating is an increased chance of soft tissue necrosis, infection, and in some cases resulting in an exposed implant. We conducted a prospective study to analyze the results of fractures of the distal in both leg bones managed by the MIPPO procedure for tibial fractures and a rush nail for fibular fractures. The study was conducted in a tertiary care hospital from November 2012 to May 2014, a total of 30 fractures in 30 patients (18 males, 12 females) with a mean age of 42.4 years (26-60 years) were treated in our institution in the aforesaid time period with MIPPO for tibia and rush nail for fibular fractures. All the cases were operated on by a single surgeon in emergency within 24 hours. The patients with skin blistering and compound fractures were excluded from this study. Rehabilitative measures were proceeded as per patient's pain profile, isometric and isotonic exercises were started on the first post-operative day, with full weight bearing at 10-12 weeks after assessing clinical and radiological union. Regular follow up of patients was done, radiographs were taken at the immediate post-operative period and at 3, 6, 12 and 24 weeks. All the patients were available for regular follow up. Radiological and clinical union proceeded normally in all the patients, no patients had signs of any deep infection, delayed union or nonunion, three patients had a superficial infection of the tibial incision that healed with a change in antibiotic. The use of dual plating for fixation of the lower tibia and fibula

  20. Nail abnormalities

    MedlinePlus

    ... appearance of the thumbnails. Long-term exposure to moisture or nail polish can cause nails to peel ... nail, if your nails are constantly exposed to moisture, or whether you are always picking at your ...

  1. Knee stabilisation following infected knee arthroplasty with bone loss and extensor mechanism impairment using a modular cemented nail.

    PubMed

    Rao, M C; Richards, O; Meyer, C; Jones, R Spencer

    2009-12-01

    Infected Total Knee Replacement with significant bone loss and loss of extensor mechanism poses a difficult management problem. Arthrodesis relying on bony union can be difficult to achieve and can result in significant limb shortening. We retrospectively looked at the outcome of seven patients with significant bone loss and extensor mechanism insufficiency following infected TKR who underwent knee stabilisation using a modular cemented nail. The nail relied on the strong coupling mechanism between the modular femoral and tibial components. Pain score improved from a mean of 7.9 pre-operatively to 1.5 post-operatively at a mean follow up of 39.6 months (range 7-68) months. Two patients underwent technically easy revision nailing for recurrent infection and aseptic loosening. The Endo-Model(R) Knee Fusion Nail (Newsplint, UK/Waldemar Link, GmbH & Co. KG, Hamburg, Germany) has good early results in terms of pain relief and provides a stable knee in cases with significant bone loss and extensor mechanism insufficiency following an infected TKR thus avoiding an above knee amputation.

  2. Dosimetry during intramedullary nailing of the tibia.

    PubMed

    Kirousis, George; Delis, Harry; Megas, Panagiotis; Lambiris, Elias; Panayiotakis, George

    2009-10-01

    Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. The mean operation time was 101 (48-240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy x cm(2). The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique.

  3. Dosimetry during intramedullary nailing of the tibia

    PubMed Central

    2009-01-01

    Background Intramedullary nailing under fluoroscopic guidance is a common operation. We studied the intraoperative radiation dose received by both the patient and the personnel. Patients and methods 25 intramedullary nailing procedures of the tibia were studied. All patients suffered from tibial fractures and were treated using the Grosse-Kempf intramedullary nail, with free-hand technique for fixation of the distal screws, under fluoroscopic guidance. The exposure, at selected positions, was recorded using an ion chamber, while the dose area product (DAP) was measured with a DAP meter, attached to the tube head. Thermoluminescent dosimeters (TLDs) were used to derive the occupational dose to the personnel, and also to monitor the surface dose on the gonads of some of the patients. Results The mean operation time was 101 (48–240) min, with a mean fluoroscopic time of 72 seconds and a mean DAP value of 75 cGy·cm2. The surface dose to the gonads of the patients was less than 8.8 mGy during any procedure, and thus cannot be considered to be a contraindication for the use of this technique. Occupational dose differed substantially between members of the operating personnel, the maximum dose recorded being to the operator of the fluoroscopic equipment (0.11 mSv). Interpretation Our findings underscore the care required by the primary operator not to exceed the dose constraint of 10 mSv per year. The rest of the operating personnel, although they do not receive very high doses, should focus on the dose optimization of the technique. PMID:19916691

  4. Failure analysis of knee arthrodesis with the WichitaFusion Nail.

    PubMed

    Parcel, Ted W; Levering, Melissa; Polikandriotis, John A; Gustke, Kenneth A; Bernasek, Thomas L

    2013-11-01

    Arthrodesis is a salvage procedure for failed total knee arthroplasty with the intent to create a stable, pain-free limb on which to ambulate or transfer. For many patients, the alternative to arthrodesis may be an above-knee amputation. Available techniques for knee arthrodesis include compression plating, external fixators, and intramedullary fixation. The purpose of this study was to report the knee fusion rate of consecutive patients at 1 institution using an intramedullary fusion nail and to identify patient risk factors for fusion failure. Between November 1998 and November 2008, twenty-eight patients undergoing knee arthrodesis with an average follow-up of 18 months (range, 3-64 months) were retrospectively studied. Demographic information, presence of fusion, clinical function, pain level, and bone defect data were collected and analyzed. Eighty-two percent (23/28) of patients had radiographic evidence of successful fusion with an average time to fusion of 21 weeks (range, 10-58 weeks). When examining patient variables that could correlate with fusion rates, patients with an Anderson Orthopaedic Research Institute type 3 femoral or type 3 tibial defect had a statistically significant lower fusion rate. The intramedullary fusion nail is an effective device for knee arthrodesis that offers ease of insertion through the knee wound with the advantages of initial bone compression and rigid fixation. Although the use of intramedullary fusion nails leads to a high fusion rate, significant bone deficiency limits successful fusion. Copyright 2013, SLACK Incorporated.

  5. Update on nail cosmetics.

    PubMed

    Jefferson, Julie; Rich, Phoebe

    2012-01-01

    Nail cosmetics are used by millions of people worldwide who desire smooth, lustrous nails. The nail cosmetic industry continues to expand to meet increasing consumer demand. In 2011 alone, consumers spent $6.6 billion on nail salon services. Although nail cosmetics are relatively safe, poor application techniques can promote disease, deformity, and allergic and irritant contact dermatitis. The foundation for managing nail cosmetic problems is prevention through education. Familiarity with the procedures and materials used in the nail cosmetic industry is necessary in order to recommend safe nail care strategies. © 2012 Wiley Periodicals, Inc.

  6. [Influencing factors for trauma-induced tibial infection in underground coal mine].

    PubMed

    Meng, W Z; Guo, Y J; Liu, Z K; Li, Y F; Wang, G Z

    2016-07-20

    Objective: To investigate the influencing factors for trauma-induced tibial infection in underground coal mine. Methods: A retrospective analysis was performed for the clinical data of 1 090 patients with tibial fracture complicated by bone infection who were injured in underground coal mine and admitted to our hospital from January 1995 to August 2015, including the type of trauma, injured parts, severity, and treatment outcome. The association between risk factors and infection was analyzed. Results: Among the 1 090 patients, 357 had the clinical manifestations of acute and chronic bone infection, 219 had red and swollen legs with heat pain, and 138 experienced skin necrosis, rupture, and discharge of pus. The incidence rates of tibial infection from 1995 to 2001, from 2002 to 2008, and from 2009 to 2015 were 31%, 26.9%, and 20.2%, respectively. The incidence rate of bone infection in the proximal segment of the tibia was significantly higher than that in the middle and distal segments (42.1% vs 18.9%/27.1%, P <0.01) . As for patients with different types of trauma (Gustilo typing) , the patients with type III fracture had a significantly higher incidence rate of bone infection than those with type I/II infection (52.8% vs 21.8%/24.6%, P <0.01) . The incidence rates of bone infection after bone traction, internal fixation with steel plates, fixation with external fixator, and fixation with intramedullary nail were 20.7%, 43.5%, 21.4%, and 26.1%, respectively, suggesting that internal fixation with steel plates had a significantly higher incidence rate of bone infection than other fixation methods ( P <0.01) . The multivariate logistic regression analysis showed that the position of tibial fracture and type of fracture were independent risk factors for bone infection. Conclusion: There is a high incidence rate of trauma-induced tibial infection in workers in underground coal mine. The position of tibial fracture and type of fracture are independent risk factors

  7. Arthrodesis of the knee with a modular titanium intramedullary nail.

    PubMed

    Arroyo, J S; Garvin, K L; Neff, J R

    1997-01-01

    We retrospectively studied the results of arthrodesis of the knee with a modular titanium intramedullary nail that couples at the knee. The study group consisted of thirteen patients who had a malignant tumor around the knee, five who had failure of a total knee arthroplasty, and three who had a locally destructive benign tumor about the knee. All of the patients were followed for a minimum of two years. Through a single incision at the knee, one nail was inserted retrograde into the femur and the other, antegrade into the tibia; the two nails were joined at the level of the knee by a conical couple and were secured with locking screws. The diameters of the nails were different, to accommodate the dissimilar sizes of the tibial and femoral intramedullary canals. A solid osseous fusion was achieved in nineteen (90 per cent) of the twenty-one patients (sixteen who had had resection of a tumor and three who had had a failed arthroplasty), at an average of 8.4 months (range, three to nineteen months) after the operation. One patient had a delayed union, but fusion was achieved after additional bone-grafting. Of the sixteen patients who were available for clinical and radiographic evaluation at the time of the study, fifteen were satisfied with the over-all outcome and thirteen had either less pain or the same amount of pain as they had had preoperatively. There were no mechanical failures of the implant and no recurrences of tumor. Complications occurred in eight (38 per cent) of the twenty-one patients: three patients had a stress fracture, three had a peroneal nerve palsy (one of which was transient), one had a superficial wound infection, and one had reflex sympathetic dystrophy.

  8. Physics of nail conditions: why do ingrown nails always happen in the big toes?

    PubMed

    Rauch, Cyril; Cherkaoui-Rbati, Mohammed

    2014-10-16

    Although surgical treatment of nail conditions can be traced back centuries to the writings of Paul Aegineta (625-690 AC), little is known about the physical laws governing nail growth. Such a poor understanding together with the increasing number of nail salons in the high street should raise legitimate concerns regarding the different procedures applied to nails. An understanding of the physics of nail growth is therefore essential to engage with human medicine and to understand the aetiology of nail conditions. In this context, a theory of nail plate adhesion, including a physical description of nail growth can be used to determine the transverse and longitudinal curvatures of the nail plate that are so important in the physical diagnosis of some nail conditions. As a result physics sheds light on: (a) why/how nails/hooves adhere strongly, yet grow smoothly; (b) why hoof/claw/nail growth rates are similar across species; (c) potential nail damage incurred by poor trimming; (d) the connection between three previously unrelated nail conditions, i.e. spoon-shaped, pincer and ingrown nails and; last but not least, (e) why ingrown nails occur preferentially in the big toes.

  9. Asymmetry in gait pattern following tibial shaft fractures - a prospective one-year follow-up study of 49 patients.

    PubMed

    Larsen, Peter; Laessoe, Uffe; Rasmussen, Sten; Graven-Nielsen, Thomas; Berre Eriksen, Christian; Elsoe, Rasmus

    2017-01-01

    Despite the high number of studies evaluating the outcomes following tibial shaft fractures, the literature lacks studies including objective assessment of patients' recovery regarding gait pattern. The purpose of the present study was to evaluate whether gait patterns at 6 and 12 months post-operatively following intramedullary nailing of a tibial shaft fracture are different compared with a healthy reference population. The study design was a prospective cohort study. The primary outcome measurement was the gait patterns at 6 and 12 months post-operatively measured with a 6-metre-long pressure-sensitive mat. The mat registers footprints and present gait speed, cadence as well as temporal and spatial parameters of the gait cycle. Gait patterns were compared to a healthy reference population. 49 patients were included with a mean age of 43.1 years (18-79 years). Forty-three patients completed the 12-month follow-up (88%). Gait speed and cadence were significantly increased between the 6- and 12-month follow-up (P<0.001). At 6-month follow-up, patients showed considerable asymmetry in the injured leg compared with the non-injured leg: single-support time 12.8% shorter, swing-time 12.8% longer, step-length 11.9% shorter, and rotation of the foot increased by 32.3%. At the 12-month follow-up, gait asymmetry become almost normalized compared to a healthy reference group. In patients treated by intramedullary nailing following a tibial shaft fracture, gait asymmetry accompanied with slower speed and cadence are common during the first 6 months and become normalized compared with a healthy reference population between 6 and 12 months post-operatively. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Green Nail Syndrome

    MedlinePlus

    ... nail is detached from the nail bed, the waterproof seal formed by the skin on the nail ... should also be noted that wearing tight-fitting shoes for a prolonged time, especially while exercising, is ...

  11. Foot and ankle function after tibial overlengthening.

    PubMed

    Emara, Khaled M; Diab, Ramy Ahmed; El Ghazali, Sherif; Farouk, Amr; El Kersh, Mohamed Ahmed

    2014-01-01

    Lengthening the tibia more than 25% of its original length can be indicated for proximal femoral deficiency, poliomyelitis, or femoral infected nonunion. Such lengthening of the tibia can adversely affect the ankle or foot shape and function. The present study aimed to assess the effect of tibial lengthening of more than 25% of its original length on the foot and ankle shape and function compared with the preoperative condition. This was a retrospective study of 13 children with severe proximal focal femoral deficiency, Aitken classification type D, who had undergone limb lengthening from June 2000 to June 2008 using Ilizarov external fixators. The techniques used in tibial lengthening included lengthening without intramedullary rodding and lengthening over a nail. The foot assessment was done preoperatively, at fixator removal, and then annually for 3 years, documenting the range of motion and deformity of the ankle and subtalar joints and big toe and the navicular height, calcaneal pitch angle, and talo-first metatarsal angle. At fixator removal, all cases showed equinocavovarus deformity, with decreased ankle, subtalar, and big toe motion. The mean American Orthopedic Foot and Ankle Society score was significantly reduced. During follow-up, the range of motion, foot deformity, and American Orthopedic Foot and Ankle Society score improved, reaching nearly to the preoperative condition by 2 years of follow-up. The results of our study have shown that tibial overlengthening has an adverse effect on foot and ankle function. This effect was reversible in the patients included in the present study. Lengthening of more than 25% can be safely done after careful discussion with the patients and their families about the probable effects of lengthening on foot and ankle function. Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  12. [Tibio-talo-calcaneal arthrodesis with the retrograde intramedullary nail MEDIN].

    PubMed

    Popelka, S; Vavřík, P; Landor, I; Bek, J; Popelka ml, S; Hromádka, R

    2013-01-01

    When the talus and the talocalcaneal joint are both affected, their fusion is the method of treatment. Ankle arthrodesis is carried out using various osteosynthetic materials such as external fixators, screws and plates. One of the options is retrograde nailing. Tibio-talo-calcaneal arthrodesis is frequently indicated in patients with rheumatoid arthritis (RA) in whom both the talus and the subtalar joint are often affected. A retrograde nail for tibio-talo-calcaneal arthrodesis was developed at our department in cooperation with MEDIN Company. This is a titanium double-curved nail, with the distal part bent at 8 degrees ventrally and 10 degrees laterally. It is inserted from the transfibular approach. Sixty-two patients, 35 women and 27 men, were treated at our department from 2005. Since one patient had bilateral surgery, 63 ankles were included. The indications for arthrodesis involved rheumatoid arthritis in 42, post-traumatic arthritis in 10, failed ankle arthrodesis in two and failed total ankle arthroplasty in five ankles; tibial stress fractures close above the ankle in two RA patients, one patient with dermatomyositis and one with lupus erythematodes. The average age at the time of surgery was 64.2 years (range, 30 to 80). The average follow-up was 4.5 years (range, 1 to 9 years), Satisfaction with the treatment outcome and willingness to undergo surgery on the other side were reported by 82% of the patients. The AOFAS score improved from 35 to 74 points. Three (4.8%) patients complained of painful feet due to the fact that exact correction of the calcaneus was not achieved and the heel after arthrodesis remained in a slightly varus position. Of them, two had a failed total ankle arthroplasty. Post-operative complications included early infection managed by antibiotic treatment and early surgical revision with irrigation.in two (3.2%) RA patients, who were undergoing biological therapy. Late infection developed at 2 to 3 years after surgery in three (4

  13. Outcomes assessment in the SPRINT multicenter tibial fracture trial: Adjudication committee size has trivial effect on trial results.

    PubMed

    Simunovic, Nicole; Walter, Stephen; Devereaux, P J; Sprague, Sheila; Guyatt, Gordon H; Schemitsch, Emil; Tornetta, Paul; Sanders, David; Swiontkowski, Marc; Bhandari, Mohit

    2011-09-01

    To evaluate how the size of an outcome adjudication committee, and the potential for dominance among its members, potentially impacts a trial's results. We conducted a retrospective analysis of data from the six-member adjudication committee in the Study to Prospectively Evaluate Reamed Intramedullary Nails in Patients with Tibial Fractures (SPRINT) Trial. We modeled the adjudication process, predicted the results and costs if smaller committees had been used, and tested for the presence of a dominant adjudicator. Use of smaller committee sizes (one to five members) would have had little impact on the final study results, although one analysis suggested that the benefit in reduction of reoperations with reamed nails in closed tibial fractures would have lost significance if committee sizes of three or less were used. We identified a significant difference between adjudicators in the number of times their original minority decisions became the final consensus decision (χ(2)=9.67, P=0.046), suggesting that dominant adjudicators were present. However, their impact on the final study results was trivial. Reducing the number of adjudicators from six to four would have led to little change in the final SPRINT study results irrespective of the significance of the original trial results, demonstrating the potential for savings in trial resources. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Is there a role for intramedullary nails in the treatment of simple pilon fractures? Rationale and preliminary results.

    PubMed

    Marcus, Matthew S; Yoon, Richard S; Langford, Joshua; Kubiak, Erik N; Morris, Andrew J; Koval, Kenneth J; Haidukewych, George J; Liporace, Frank A

    2013-08-01

    Certain patients with pilon fractures present with significant soft-tissue swelling or with a poor soft-tissue envelope typically not amenable to definitive fixation in the early time period. The objective of this study was to review the treatment of simple intra-articular fractures of the tibial plafond (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association (AO/OTA) type 43C1-C2) via intramedullary nailing (IMN) with the assessment of clinical and radiographic results and any associated complications. Retrospective clinical and radiological reviews of 31 patients sustaining AO/OTA type 43C distal tibial fractures treated with IMN were evaluated. Our main outcome measurement included achievable alignment in the immediate postoperative period and at the time of union along with complications or need for secondary procedures within the first year of follow-up. Seven patients were lost to follow-up. All the remaining patients achieved bony union at a mean union time of 14.1 ± 4.9 weeks with no evidence of malunion or malrotation. All patients were at full-weight-bearing status at 1-year follow-up. Complications were notable for one delayed union, one non-union, one patient with superficial wound drainage, two with deep infection, one with symptomatic hardware and one with deep vein thrombosis. Simple articular fractures of the tibial plafond (AO/OTA type 43C) treated via IMN can achieve excellent alignment and union rates with proper patient selection and surgical indication. One should not hesitate to use additional bone screws or plating options to help achieve better anatomic reduction. However, larger, prospective randomised trials comparing plating versus nailing, in experienced hands, are needed to completely delineate the utility of this treatment modality. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Understanding the Formidable Nail Barrier: A Review of the Nail Microstructure, Composition and Diseases

    PubMed Central

    Baswan, Sudhir; Kasting, Gerald B.; Li, S. Kevin; Wickett, Randy; Adams, Brian; Eurich, Sean; Schamper, Ryan

    2016-01-01

    The topical treatment of nail fungal infections has been a focal point of nail research in the past few decades as it offers a much safer and focused alternative to conventional oral therapy. Although the current focus remains on exploring the ways of enhancing permeation through the formidable nail barrier, the understanding of the nail microstructure and composition is far from complete. This article reviews our current understanding of the nail microstructure, composition and diseases. A few of the parameters affecting the nail permeability and potential causes of the recurrence of fungal nail infection are also discussed. PMID:28098391

  16. Understanding the formidable nail barrier: A review of the nail microstructure, composition and diseases.

    PubMed

    Baswan, Sudhir; Kasting, Gerald B; Li, S Kevin; Wickett, Randy; Adams, Brian; Eurich, Sean; Schamper, Ryan

    2017-05-01

    The topical treatment of nail fungal infections has been a focal point of nail research in the past few decades as it offers a much safer and focused alternative to conventional oral therapy. Although the current focus remains on exploring the ways of enhancing permeation through the formidable nail barrier, the understanding of the nail microstructure and composition is far from complete. This article reviews our current understanding of the nail microstructure, composition and diseases. A few of the parameters affecting the nail permeability and potential causes of the recurrence of fungal nail infection are also discussed. © 2017 Blackwell Verlag GmbH.

  17. Minimally-invasive plate osteosynthesis in distal tibial fractures: Results and complications.

    PubMed

    Vidović, Dinko; Matejčić, Aljoša; Ivica, Mihovil; Jurišić, Darko; Elabjer, Esmat; Bakota, Bore

    2015-11-01

    Distal tibial or pilon fractures are usually the result of combined compressive and shear forces, and may result in instability of the metaphysis, with or without articular depression, and injury to the soft tissue. The complexity of injury, lack of muscle cover and poor vascularity make these fractures difficult to treat. Surgical treatment of distal tibial fractures includes several options: external fixation, IM nailing, ORIF and minimally-invasive plate osteosynthesis (MIPO). Management of distal tibial fractures with MIPO enables preservation of soft tissue and remaining blood supply. This is a report of a series of prospectively studied closed distal tibial and pilon fractures treated with MIPO. A total of 21 patients with closed distal tibial or pilon fractures were enrolled in the study between March 2008 and November 2013 and completed follow-up. Demographic characteristics, mechanism of injury, time required for union, ankle range of motion and complications were recorded. Fractures were classified according to the AO/OTA classification. Nineteen patients were initially managed with an ankle-spanning external fixator. When the status of the soft tissue had improved and swelling had subsided enough, a definitive internal fixation with MIPO was performed. Patients were invited for follow-up examinations at 3 and 6 weeks and then at intervals of 6 to 8 weeks until 12 months. Mean age of the patients was 40.1 years (range 19-67 years). Eighteen cases were the result of high-energy trauma and three were the result of low-energy trauma. According to the AO/OTA classification there were extraarticular and intraarticular fractures, but only simple articular patterns without depression or comminution. The average time for fracture union was 19.7 weeks (range 12-38 weeks). Mean range of motion was 10° of dorsiflexion (range 5-15°) and 28.3° of plantar flexion (range 20-35°). Three cases were metalwork-related complications. Two patients underwent plate removal

  18. Does graded reaming affect the composition of reaming products in intramedullary nailing of long bones?

    PubMed

    Kouzelis, Antonis Th; Kourea, Helen; Megas, Panagiotis; Panagiotopoulos, Elias; Marangos, Markos; Lambiris, Elias

    2004-08-01

    Reaming products taken during intramedullary nailing were examined to identify possible differences in their composition depending on the reaming percentage. Reaming products were taken from 39 fresh closed tibial and femoral diaphyseal fractures in patients with an average age of 29 years. According to histology, reaming products mainly consisted of bone trabeculae, viable or nonviable, and bone marrow stroma. A statistically significant reverse correlation exists between viable bone mass percentage and reaming progress. Reaming 1 mm less than the minimum canal diameter provides a higher viable bone mass percentage, which might be an important factor in the bone healing process.

  19. [Pyoderma gangrenosum after intramedullary nailing of tibial shaft fracture: A differential diagnosis to necrotizing fasciitis].

    PubMed

    Hackl, S; Merkel, P; Hungerer, S; Friederichs, J; Müller, N; Militz, M; Bühren, V

    2015-12-01

    Pyoderma gangrenosum is a rare non-infectious neutrophilic dermatitis, whereas necrotizing fasciitis is a life-threatening bacterial soft tissue infection of the fascia and adjacent skin. As in the case described here after intramedullary nailing, the clinical appearance of both diseases can be similar. Because of the completely different therapeutic approach and a worse outcome in the case of false diagnosis, pyoderma gangrenosum should always be taken into consideration before treating necrotizing fasciitis.

  20. Histopathological examination of bone debris from reaming of interlocking intra-medullary nail fixation of long bone fractures with concomitant head injury.

    PubMed

    Khallaf, Fathy G; Kehinde, Elijah O

    2015-12-01

    The aim of study was to test, for the presence of osteoblasts in the reaming debris of intramedullary nailing of femoral and tibial fracture in patients with and without severe head injury. Two groups of patients were studied. Group A (n = 32) had long bone fractures in addition to having head injuries. Group B (n = 35) had only long bone fractures. The fractures in the 2 groups of patients was treated by inter medullary nailing. Osteoblasts in the debris of the inter medullary nailing was compared between the 2 groups of patients. The results demonstrated that histopathological specimens from reaming debris of fractured femur and tibia in patients with head injury showed osteoblasts in (82.9%) and in (27.5%) of patients with isolated long bone fractures (p < 0.001). Healing indicators in diaphyseal fractures and concomitant head injury confirm fast and adequate healing in these patients and the presence of plenty of osteoblasts in their reaming debris may reflect a proof of accelerated fracture healing environment.

  1. Fat embolism syndrome in an adolescent before surgical treatment of an isolated closed tibial shaft fracture.

    PubMed

    Nawaf, Cayce B; Kelly, Derek M; Warner, William C; Beaty, James H; Rhodes, Leslie; Sawyer, Jeffrey R

    2012-12-01

    Fat embolism syndrome (FES) occurs most commonly in adults with high-energy trauma, especially fractures of the long-bones and pelvis. Because of unique age-related physiologic differences in the immature skeleton, as well as differences in fracture management in pediatric patients, FES is rare in children. To our knowledge, this is the first case report of FES occurring before surgical fixation of a closed tibial shaft fracture in an adolescent. A 16-year-old, 109 kg, Caucasian adolescent boy developed FES after closed diaphyseal fractures of the distal tibia and fibula, showing signs of respiratory distress and mental status changes. The FES resolved with supportive respiratory care and intramedullary nailing of the fracture was done without further respiratory compromise. FES is uncommon in children and adolescents. A high index of suspicion is required to make the diagnosis promptly and institute appropriate treatment. Intramedullary nailing of a long-bone fracture can be done safely and successfully after resolution of the FES.

  2. Anthropometric measurements of tibial plateau and correlation with the current tibial implants.

    PubMed

    Erkocak, Omer Faruk; Kucukdurmaz, Fatih; Sayar, Safak; Erdil, Mehmet Emin; Ceylan, Hasan Huseyin; Tuncay, Ibrahim

    2016-09-01

    The aim of the study was to make an anthropometric analysis at the resected surfaces of the proximal tibia in the Turkish population and to compare the data with the dimensions of tibial components in current use. We hypothesized that tibial components currently available on the market do not fulfil the requirements of this population and a new tibial component design may be required, especially for female patients with small stature. Anthropometric data from the proximal tibia of 226 knees in 226 Turkish subjects were measured using magnetic resonance imaging. We measured the mediolateral, middle anteroposterior, medial and lateral anteroposterior dimensions and the aspect ratio of the resected proximal tibial surface. All morphological data were compared with the dimensions of five contemporary tibial implants, including asymmetric and symmetric design types. The dimensions of the tibial plateau of Turkish knees demonstrated significant differences according to gender (P < 0.05). Among the different tibial implants reviewed, neither asymmetric nor symmetric designs exhibited a perfect conformity to proximal tibial morphology in size and shape. The vast majority of tibial implants involved in this study tend to overhang anteroposteriorly, and a statistically significant number of women (21 %, P < 0.05) had tibial anteroposterior diameters smaller than the smallest available tibial component. Tibial components designed according to anthropometric measurements of Western populations do not perfectly meet the requirements of Turkish population. These data could provide the basis for designing the optimal and smaller tibial component for this population, especially for women, is required for best fit. II.

  3. Objective guidelines for removing an external fixator after tibial lengthening using pixel value ratio: a pilot study.

    PubMed

    Zhao, Li; Fan, Qing; Venkatesh, K P; Park, Man S; Song, Hae Ryong

    2009-12-01

    During limb lengthening over an intramedullary nail, decisions regarding external fixator removal and weightbearing depend on the amount of callus seen at the lengthening area on radiographs. However, this method is subjective and objective evaluation of the amount of callus likely would minimize nail or interlocking screw breakage and refracture after fixator removal. We asked how many cortices with full corticalization of the newly formed bone at the lengthening area are needed to allow fixator removal and full weightbearing and how to radiographically determine the stage of corticalization. We retrospectively reviewed 17 patients (34 lengthenings) who underwent bilateral tibial lengthenings over an intramedullary nail. The average gain in length was 7.2 +/- 3.4 cm. We determined the pixel value ratio (ratio of pixel value of regenerate versus the mean pixel value of adjacent bone) of the lengthened area on radiographs. There were no nail or screw breakage and refracture. Partial weightbearing with crutches was permitted when the pixel value ratio was 1 in two cortices and full weightbearing without crutches was permitted when the pixel value ratio was 1 in three cortices. The pixel value ratio on radiographs can be an objective parameter for callus measurement and may provide guidelines for the timing of external fixator removal. We cannot determine from our limited data the minimum pixel value in how many cortices would suggest safe removal, but we can say our criteria were not associated with subsequent refracture.

  4. [Intramedullary nailing of the tibia with the expert tibia nail].

    PubMed

    Hansen, Matthias; El Attal, René; Blum, Jochen; Blauth, Michael; Rommens, Pol Maria

    2009-12-01

    Restoration of axis, length, and rotation of the lower leg. Sufficient primary stability of the osteosynthesis for functional aftercare. Early functional aftercare to maintain joint mobility. Good bony healing in closed and open fractures. All closed and open fractures of the tibia and complete lower leg fractures (AO 42). Certain extraarticular fractures of the proximal and distal tibia (AO 41 A2/A3; AO 43 A1/A2/A3). Segmental fractures of the tibia. Certain intraarticular fractures of the tibia with use of additional implants (AO 41 C1/C2; AO 43 C1/C2). Stabilization during and after segmental bone transport or callus distraction of the tibia. Patients in poor general condition (e.g., bedridden). Flexion of the knee of less than 90 degrees . Infection in the nail's insertion area. Infection of the tibial cavity. Complex articular fractures of the proximal or distal tibia with joint depression. Closed reduction of the fracture. If necessary, use of reduction clamps through additional stab incisions or open surgical procedures. In some cases, additional osteosynthesis procedures are necessary (e.g., screws). Positioning of the patient may be performed on a radiolucent table or a traction table. Opening of the proximal tibia in line with the medullary canal. Cannulated or noncannulated insertion of the Expert Tibia Nail((R)) with or without reaming of the medullary canal depending on the fracture type and soft-tissue condition. Control of axis, length, and rotation. Distal interlocking with the radiolucent drill and proximal interlocking with the targeting device. Immediate mobilization of ankle joint and knee joint. Depending on the type of fracture, mobilization with 20 kg partial weight bearing or pain-dependent full weight bearing with crutches. X-ray control 6 weeks postoperatively and increased weight bearing depending on the fracture status. In a prospective, international multicentric study, 181 patients with 186 fractures were included between July 2004 and

  5. Induced membrane technique combined with two-stage internal fixation for the treatment of tibial osteomyelitis defects.

    PubMed

    Luo, Fei; Wang, Xiaohua; Wang, Shulin; Fu, Jingshu; Xie, Zhao

    2017-07-01

    The purpose of this study was to observe the effects of induced membrane technique combined with two-stage internal fixation in the treatment of tibial osteomyelitis defects. A retrospective analyses for 67 cases of tibialosteomyelitis defects were admitted to our department between September 2012 to February 2015, which were treated with induced membrane technique. At the first stage, implanted with a PMMA cement spacer in the defects after radical debridement and fixed with reconstructive locked plate. Bone grafting and exchanged the plate with intramedullary nail at the second stage. In current study, all patients were followed up for 18-35 months. Sixty-six patients achieved bone union with the average radiographic and clinical healing times of 5.55±2.19 and 7.45±1.69months, respectively. Seven patients required a second debridement before grafting, while four patients experienced a recurrence of infection or a relapse following second stage treatment. Twelve patients experienced either knee or ankle dysfunctions and 2 patients faced delayed wound healing. Donor site complications includes pain and infection were found in 7 and 3 patients, respectively with delayed stress fracture in 1 patient only. Induced membrane technique for the treatment of tibial osteomyelitis defects, seems a reliable method. The use of reconstructive locked plate as a temporary internal fixation at the first stage and exchanged with intramedullary nail at the second stage, potentially achieves good clinical efficacy. Care should be taken to restore the joint function especially in distal tibia. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Paediatric tibial shaft fractures treated by open reduction and stabilization with monolateral external fixation

    PubMed Central

    Simon, A.-L.; Apostolou, N.; Vidal, C.; Ferrero, E.; Mazda, K.; Ilharreborde, B.

    2018-01-01

    Abstract Purpose Elastic stable intramedullary nailing is increasingly used for surgical treatment of tibial shaft fractures, but frequently requires immobilization and delayed full weight-bearing. Therefore, external fixation remains interesting. The aim was to report clinico-radiological outcomes of monolateral external fixation for displaced and unstable tibial shaft fractures in children. Methods All tibial fractures consecutively treated by monolateral external fixation between 2008 and 2013 were followed. Inclusion criteria included skeletal immaturity and closed and open Gustilo I fractures caused by a direct impact. Patients were seen until two years postoperatively. Demographics, mechanism of injury, surgical data and complications were recorded. Anteroposterior and lateral side radiographs were performed at each visit. Full-limb 3D reconstructions using biplanar stereroradiography was performed for final limb length and alignment measures. Results A total of 45 patients (mean age 9.7 years ± 0.5) were included. In all, 17 were Gustilo I fractures, with no difference between open and closed fractures for any data. Mean time to full weight bearing was 18.2 days ± 0.7. After 15 days, 39 patients returned to school. Hardware removal (mean time to union 15.6 weeks ± 0.8) was performed during consultation under analgesic gas. There were no cases of nonunion. No fracture healed with > 10° of angulation (mean 5.1° ± 0.4°). Leg-length discrepancy > 10 mm was found for six patients. Conclusions This procedure can be a safe and simple surgical treatment for children with tibial shaft fractures. Few complications and early return to school were reported, with the limitations of non-comparative study. Level of Evidence IV PMID:29456750

  7. [Tibiotalocalcaneal arthrodesis using a retrograde nail locked in the sagittal plane].

    PubMed

    Veselý, R; Procházka, V; Visna, P; Valentová, J; Savolt, J

    2008-04-01

    To evaluate our experience with the use of a retrograde nail locked in the sagittal plane for tibiotalocalcaneal arthrodesis indicated in severe post-traumatic arthritis of the ankle. Twenty patients, 16 men and four women at an average age of 58.7 years (range, 23 to 72) were evaluated. All patients had severe post-traumatic changes in the talocrural and talocalcaneal joints. Five patients also had an equinus deformity. In two patients arthrodesis followed the treatment of purulent arthritis of the talocrural joint. A local fasciocutaneous flap was used for soft tissue reconstruction in three patients. All patients were operated on using the standard surgical technique. METHODS With the patient in a supine position, reamed by hand with the use of a driving rod, a straight retrograde AAN Orthofix nail was inserted through the heel bone and talus into the distal tibia and locked in these bones in the sagittal plane. No complications such as injury to the neurovascular plexus or pseudoarthrosis were recorded. Four patients showed a reaction to the proximal locking screw on the proximal tibial surface, which was treated by earlier screw removal under topical anaesthesia. Due to infectious complications, the nail had to be removed prematurely in one patient. The average Foot Function Index was 12 points (range, 10 to 15) and the average ankle-hindfoot score was 67.6 points (range, 59 to 84). Thirteen patients (65 %) were not limited in their daily activities or recreational sports, six (30 %) experienced pain in sports but not daily activities and one patient (5 %) reported pain even when walking. All fusions healed in the correct position within 18 weeks. Tibiotalocalcaneal arthrodesis is not a frequent surgical procedure in either trauma surgery or orthopaedics. For this complicated procedure, rather than intramedullary nails, internal fixation with screws or plates or external fixation are preferred. The high rate of bony healing can be explained by maintenance of

  8. Dermoscopy in the Evaluation of Nail Disorders

    PubMed Central

    Alessandrini, Aurora; Starace, Michela; Piraccini, Bianca Maria

    2017-01-01

    Nail dermoscopy was initially used only in the assessment of nail pigmentation, but now it is widely utilized for the evaluation of many nail disorders. In daily practice, dermoscopy may confirm clinical diagnoses and guides in the management of nail diseases and treatments, permitting a better visualization of symptoms. Dry dermoscopy is required for evaluation of the nail plate surface, while gel as an interface is necessary for assessment of nail pigmentation and onycholysis, as well as for the evaluation of the distal nail margin. In this review, we describe the dermoscopic features of the most important nail disorders, looking at the different areas of the nail. Dermatoscopic changes that usually accompany specific nail diseases are also reviewed. PMID:28560217

  9. Kinematically aligned total knee arthroplasty limits high tibial forces, differences in tibial forces between compartments, and abnormal tibial contact kinematics during passive flexion.

    PubMed

    Roth, Joshua D; Howell, Stephen M; Hull, Maury L

    2018-06-01

    Following total knee arthroplasty (TKA), high tibial forces, large differences in tibial forces between the medial and lateral compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion indicate abnormal knee function. Because the goal of kinematically aligned TKA is to restore native knee function without soft tissue release, the objectives were to determine how well kinematically aligned TKA limits high tibial forces, differences in tibial forces between compartments, and anterior translation of the contact locations of the femoral component on the tibial component during passive flexion. Using cruciate retaining components, kinematically aligned TKA was performed on thirteen human cadaveric knee specimens with use of manual instruments without soft tissue release. The tibial forces and tibial contact locations were measured in both the medial and lateral compartments from 0° to 120° of passive flexion using a custom tibial force sensor. The average total tibial force (i.e. sum of medial + lateral) ranged from 5 to 116 N. The only significant average differences in tibial force between compartments occurred at 0° of flexion (29 N, p = 0.0008). The contact locations in both compartments translated posteriorly in all thirteen kinematically aligned TKAs by an average of 14 mm (p < 0.0001) and 18 mm (p < 0.0001) in the medial and lateral compartments, respectively, from 0° to 120° of flexion. After kinematically aligned TKA, average total tibial forces due to the soft tissue restraints were limited to 116 N, average differences in tibial forces between compartments were limited to 29 N, and a net posterior translation of the tibial contact locations was observed in all kinematically aligned TKAs during passive flexion from 0° to 120°, which are similar to what has been measured previously in native knees. While confirmation in vivo is warranted, these findings give

  10. Nail toxicity induced by cancer chemotherapy.

    PubMed

    Gilbar, Peter; Hain, Alice; Peereboom, Veta-Marie

    2009-09-01

    To provide a comprehensive literature review of chemotherapy-induced nail toxicity, including clinical presentation, implicated drugs and approaches for prevention and management. A search of MEDLINE and EMBASE (1966-2008) databases was conducted using the terms (and variations of the terms) antineoplastic agents, nails, nail toxicity, onycholysis, and paronychia. Bibliographies from selected articles were reviewed for appropriate references. The retrieved literature was reviewed to include all articles relevant to the clinical presentation, diagnosis, incidence, prevention, and treatment of chemotherapy-induced nail toxicity. Nail toxicity is a relatively uncommon adverse effect linked to a number of chemotherapeutic agents. Clinical presentation varies, depending on which nail structure is affected and the severity of the insult. Nail changes may involve all or some nails. Toxicity may be asymptomatic and limited to cosmetic concerns, however, more severe effects, involving pain and discomfort can occur. Taxanes and anthracyclines are the antineoplastic drug groups most commonly implicated. It is suggested that the administration schedule may influence the incidence of nail abnormalities, for example reported cases linked to the weekly administration of paclitaxel.Before instituting chemotherapy, patients should be educated regarding potential nail toxicities and strategies for prevention implemented. Management includes appropriate nail cutting, avoiding potential irritants, topical, or oral antimicrobials, and possibly cessation or dose reduction of the offending agent. Cryotherapy, through the application of frozen gloves or socks, has been beneficial in reducing docetaxel-induced nail toxicity and may be effective for other drugs.

  11. The effect of nail polish and acrylic nails on pulse oximetry reading using the Lifebox oximeter in Nigeria.

    PubMed

    Desalu, I; Diakparomre, O I; Salami, A O; Abiola, A O

    2013-12-01

    AIMS AND OBJECTIVES - Pulse oximetry is mandatory during anaesthesia, sedation and transfer of critically ill patients. The effect of nail polish and acrylic nails on the accuracy of saturation reading is inconsistent. The Lifebox pulse oximeter is reliable and recommended for low and middle income countries. We investigated its accuracy in the presence of 4 nail colours and acrylic nails SUBJECTS AND METHODS Fifty non-smoking volunteers had their fingers numbered from right to left (little finger of right hand =1 and little finger of left hand =10). Alternate fingers were nails painted with clear, red, brown and black nail polish and the 5th finger had acrylic nail applied. The corresponding finger on the other hand acted as control. The oxygen saturation was determined using the Lifebox pulse oximeter. Results All fingers (100%) with clear nail polish, red nail polish and acrylic nails recorded a saturation value. Each of the mean saturation value for clear nail polish, red nail polish and acrylic nails was not significantly different from the control mean (p= 0.378, 0.427 and 0.921). Only 12% and 64% of nails polished black and brown respectively recorded a saturation value. The mean SpO- for black and brown polish were significantly different from their control mean (p<0.001). CONCLUSION Black and brown polish resulted in a significant decrease in SpO with the Lifebox oximeter. Dark coloured nail polish should be removed prior to SpO2 determination to ensure that accurate readings can be obtained.

  12. Nail-Gun Injuries to the Hand

    PubMed Central

    Pierpont, Yvonne N.; Pappas-Politis, Effie; Naidu, Deepak K.; Salas, R. Emerick; Johnson, Erika L.; Payne, Wyatt G.

    2008-01-01

    Background: The nail gun is a commonly utilized tool in carpentry and construction. When used properly with appropriate safety precautions, it can facilitate production and boost efficiency; however, this powerful tool also has the potential to cause serious injury. The most common site of nail-gun injuries in both industrial and nonoccupational settings is the hand. Materials and Methods: We report on two patients with nail-gun injuries to the hand. A review of the literature and discussion of clinical evaluation and treatment of nail-gun injuries to the hand are presented. Results: Two patients present with soft tissue injuries to the hand with the nail embedded and intact at the injury site. Operative removal of the nail and wound care resulted in successful treatment in both cases. Nail-gun injuries to the hand vary in severity on the basis of the extent of structural damage. Treatment is based on the severity of injury and the presence and location of barbs on the penetrating nail. Conclusion: Healthcare providers must understand and educate patients on the prevention mechanics of nail-gun injuries. Nail-gun injuries to the hand necessitate appropriate evaluation techniques, understanding of surgical management versus nonsurgical management, and awareness of potential pitfalls in treatment. PMID:19079574

  13. Delayed diagnosis of a peroneal artery false aneurysm at a concomitant tibial fracture. A case report.

    PubMed

    Tyllianakis, M; Panagiotopoulos, E; Megas, P; Lambiris, E

    1995-07-01

    A 49-year-old man had posttraumatic persistent calf swelling and a tibial and fibular fracture. Despite the intramedullary nailing of the fracture, the swelling did not improve, and at the 6th postoperative week it was misdiagnosed (using venogram) as deep vein thrombosis. Therefore, it was mistreated with anticoagulants, which led to great deterioration of the local signs. An arteriogram revealed an initially missed false peroneal artery aneurysm. Surgical treatment was performed immediately. The 6-week delay had led to some atrophy of the posterior compartment muscles, fortunately without any permanent disability. The importance of proper and early diagnosis of posttraumatic persistent calf swelling is stressed.

  14. Medial Tibial Stress Shielding: A Limitation of Cobalt Chromium Tibial Baseplates.

    PubMed

    Martin, J Ryan; Watts, Chad D; Levy, Daniel L; Kim, Raymond H

    2017-02-01

    Stress shielding is a well-recognized complication associated with total knee arthroplasty. However, this phenomenon has not been thoroughly described. Specifically, no study to our knowledge has evaluated the radiographic impact of utilizing various tibial component compositions on tibial stress shielding. We retrospectively reviewed 3 cohorts of 50 patients that had a preoperative varus deformity and were implanted with a titanium, cobalt chromium (CoCr), or an all polyethylene tibial implant. A radiographic comparative analysis was performed to evaluate the amount of medial tibial bone loss in each cohort. In addition, a clinical outcomes analysis was performed on the 3 cohorts. The CoCr was noted to have a statistically significant increase in medial tibial bone loss compared with the other 2 cohorts. The all polyethylene cohort had a statistically significantly higher final Knee Society Score and was associated with the least amount of stress shielding. The CoCr tray is the most rigid of 3 implants that were compared in this study. Interestingly, this cohort had the highest amount of medial tibial bone loss. In addition, 1 patient in the CoCr cohort had medial soft tissue irritation which was attributed to a prominent medial tibial tray which required revision surgery to mitigate the symptoms. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Management of Gustilo Anderson III B open tibial fractures by primary fascio-septo-cutaneous local flap and primary fixation: The 'fix and shift' technique.

    PubMed

    Ramasamy, P R

    2017-01-01

    Open fractures of tibia have posed great difficulty in managing both the soft tissue and the skeletal components of the injured limb. Gustilo Anderson III B open tibial fractures are more difficult to manage than I, II, and III A fractures. Stable skeletal fixation with immediate soft tissue cover has been the key to the successful outcome in treating open tibial fractures, in particular, Gustilo Anderson III B types. If the length of the open wound is larger and if the exposed surface of tibial fracture and tibial shaft is greater, then the management becomes still more difficult. Thirty six Gustilo Anderson III B open tibial fractures managed between June 2002 and December 2013 with "fix and shift" technique were retrospectively reviewed. All the 36 patients managed by this technique had open wounds measuring >5 cm (post debridement). Under fix and shift technique, stable fixation involved primary external fixator application or primary intramedullary nailing of the tibial fracture and immediate soft tissue cover involved septocutaneous shift, i.e., shifting of fasciocutaneous segments based on septocutaneous perforators. Primary fracture union rate was 50% and reoperation rate (bone stimulating procedures) was 50%. Overall fracture union rate was 100%. The rate of malunion was 14% and deep infection was 16%. Failure of septocutaneous shift was 2.7%. There was no incidence of amputation. Management of Gustilo Anderson III B open tibial fractures with "fix and shift" technique has resulted in better outcome in terms of skeletal factors (primary fracture union, overall union, and time for union and malunion) and soft tissue factors (wound healing, flap failure, access to secondary procedures, and esthetic appearance) when compared to standard methods adopted earlier. Hence, "fix and shift" could be recommended as one of the treatment modalities for open III B tibial fractures.

  16. Effect of mechanical forces on finger nail curvature: an analysis of the effect of occupation on finger nails.

    PubMed

    Sano, Hitomi; Shionoya, Kaori; Ogawa, Rei

    2014-04-01

    We studied the relationship between mechanical force and nail curvature. The effect of different frequencies and strengths of mechanical force on nail curvature was assessed. In Study 1, 63 carpenters and 63 office workers were enrolled, and the configurations of their thumb nails were assessed by measuring the curve index (defined as nail height/width) and pinch strength. In Study 2, nail curvature and pinch strength of jazz bassists, who characteristically do not use the right fourth and fifth fingers but use the left fifth finger a lot, were compared. In Study 3, the thumb nail curvature and pinch strength of the dominant and nondominant sides of the 126 participants from Study 1 were compared. Study 1: Carpenters had a significantly lower mean thumb nail curve index and higher mean pinch strength. Study 2: The nails of the unused right fourth and fifth fingers were much more curved than the nails of the frequently used left fourth and fifth fingers. The pinch strength of the right fifth finger was much weaker than the pinch strength of the left fifth finger. Study 3: The dominant side had a significantly lower nail curve index and higher pinch strength. The frequency and strength of mechanical forces on finger nails significantly affect nail appearance. © 2014 by the American Society for Dermatologic Surgery, Inc. Published by Wiley Periodicals, Inc.

  17. Revisiting Pneumatic Nail Gun Trigger Recommendations

    PubMed Central

    Albers, James; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-01-01

    Summary Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry. PMID:26366020

  18. Revisiting Pneumatic Nail Gun Trigger Recommendations.

    PubMed

    Albers, James; Lowe, Brian; Lipscomb, Hester; Hudock, Stephen; Dement, John; Evanoff, Bradley; Fullen, Mark; Gillen, Matt; Kaskutas, Vicki; Nolan, James; Patterson, Dennis; Platner, James; Pompeii, Lisa; Schoenfisch, Ashley

    2015-03-01

    Use of a pneumatic nail gun with a sequential actuation trigger (SAT) significantly diminishes the risk for acute traumatic injury compared to use of a contact actuation trigger (CAT) nail gun. A theoretically-based increased risk of work-related musculoskeletal disorders from use of a SAT nail gun, relative to CAT, appears unlikely and remains unproven. Based on current knowledge, the use of CAT nail guns cannot be justified as a safe alternative to SAT nail guns. This letter provides a perspective of ergonomists and occupational safety researchers recommending the use of the sequential actuation trigger for all nail gun tasks in the construction industry.

  19. Defining the Lower Limit of a "Critical Bone Defect" in Open Diaphyseal Tibial Fractures.

    PubMed

    Haines, Nikkole M; Lack, William D; Seymour, Rachel B; Bosse, Michael J

    2016-05-01

    To determine healing outcomes of open diaphyseal tibial shaft fractures treated with reamed intramedullary nailing (IMN) with a bone gap of 10-50 mm on ≥50% of the cortical circumference and to better define a "critical bone defect" based on healing outcome. Retrospective cohort study. Forty patients, age 18-65, with open diaphyseal tibial fractures with a bone gap of 10-50 mm on ≥50% of the circumference as measured on standard anteroposterior and lateral postoperative radiographs treated with IMN. IMN of an open diaphyseal tibial fracture with a bone gap. Level-1 trauma center. Healing outcomes, union or nonunion. Forty patients were analyzed. Twenty-one (52.5%) went on to nonunion and nineteen (47.5%) achieved union. Radiographic apparent bone gap (RABG) and infection were the only 2 covariates predicting nonunion outcome (P = 0.046 for infection). The RABG was determined by measuring the bone gap on each cortex and averaging over 4 cortices. Fractures achieving union had a RABG of 12 ± 1 mm versus 20 ± 2 mm in those going on to nonunion (P < 0.01). This remained significant when patients with infection were removed. Receiver operator characteristic analysis demonstrated that RABG was predictive of outcome (area under the curve of 0.79). A RABG of 25 mm was the statistically optimal threshold for prediction of healing outcome. Patients with open diaphyseal tibial fractures treated with IMN and a <25 mm RABG have a reasonable probability of achieving union without additional intervention, whereas those with larger gaps have a higher probability of nonunion. Research investigating interventions for RABGs should use a predictive threshold for defining a critical bone defect that is associated with greater than 50% risk of nonunion without supplementary treatment. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  20. Impact of a healthy nails program on nail-biting in Turkish schoolchildren: a controlled pretest-posttest study.

    PubMed

    Ergun, Ayse; Toprak, Rumeysa; Sisman, Fatma Nevin

    2013-12-01

    This study was conducted to examine the effect of a healthy nails program on nail-biting in Turkish schoolchildren. This quasi-experimental study was of pretest-posttest control group design. A total of 50 students of a primary school formed the intervention group, while 53 students from the same school formed the control group. Data were collected with a demographic form, a nail-biting follow-up form, and photographs of the fingernails. It was found that 68.9% of students were biting seven or more of their nails; 46.6% had damaged nail beds. In the intervention group, the rate of the children who were not biting their nails (baseline = 0%, 4th week = 56.0%, 8th week = 64.0%) increased significantly compared to the control group (baseline = 0%, 4th week = 15.1%, 8th week = 18.9%). Outcomes indicate the efficacy of the healthy nails program in reducing the nail-biting problem in schoolchildren.

  1. [Arthrodesis (with/without correction) of the ankle and subtalar joint: A3 nail fixation with triple bending and mechanical navigation].

    PubMed

    Richter, M

    2014-08-01

    Restoration of a stable and plantigrade foot in deformities of the ankle and/or hindfoot and concomitant degenerative changes at the ankle and subtalar joints. Deformities at the ankle and/or hindfoot and concomitant degenerative changes at the ankle and subtalar joint. Failed (corrective) arthrodesis of the ankle and subtalar joints. Fused ankle and degeneration of the subtalar joint. Failed total ankle replacement with insufficient substance of talar body and/or degeneration of subtalar joint. Massive hindfoot instability. Active local infection or relevant vascular insufficiency, possible preservation of the ankle or subtalar joint (relative contraindication). Prone position and posterolateral approach to ankle and subtalar joints (alternative supine position/anterior approach; lateral position/lateral approach). Exposition of ankle and subtalar joints and removal of remaining cartilage. Optional corrective osteotomies and/or bone grafting. Correction and optional fixation of the corrected position with 2.0 mm K-wires. Mechanically navigated insertion of a retrograde guide wire in projection of the tibial axis and insertion of a second guide wire through the entry point of the nail lateral and dorsal to the tibial axis. Reaming and insertion of the A3 nail with a distal double bend; one posterior and one lateral, and a proximal bend corresponding to a slight recurvatum. Insertion of locking screws into the calcaneus, talus and tibia (twice with optional static or dynamic locking). Optional compression between calcaneus and talus, and between tibia and talus. Insertion of a drainage and layer-wise closure. For the first 6 weeks 15 kg partial weight bearing in an orthosis, followed by full weight bearing in a stable standard shoe. In October 2010 (n = 2) and from 15 October 2011 to 13 April 2012 (n = 26) 28 arthrodeses (with/without correction) with A3 fixation were performed. In all cases, exact nail placement was achieved. Thirteen cases completed

  2. Nail disorders in infants and children.

    PubMed

    Piraccini, Bianca Maria; Starace, Michela

    2014-08-01

    Nail diseases in infants and children are an uncommon cause of consultation and are often difficult to diagnose and to manage. This review will cover nail diseases that are most commonly seen in clinical practice, including congenital and hereditary disorders and inflammatory, infective, and neoplastic nail diseases. The purpose of the review is to help the reader to recognize nail disorders at an early age and to manage them appropriately. Two recent large studies have reported the clinical findings of genetic disorders involving the nails, that is, pachyonychia congenita and epidermolysis bullosa. Only a few articles gave a comprehensive review of a disease, as occurred for onychomycosis, while the majority of the reports published in the recent literature involve single cases. Nail diseases in children and neonates are not easy to diagnose by nonexperts. Basic knowledge of the anatomy and biology of the nail facilitates their diagnosis as the understanding of their pathophysiology. This review gives hints at the most common nail diseases that affect infants and children.

  3. Do biodegradable magnesium alloy intramedullary interlocking nails prematurely lose fixation stability in the treatment of tibial fracture? A numerical simulation.

    PubMed

    Wang, Haosen; Hao, Zhixiu; Wen, Shizhu

    2017-01-01

    Intramedullary interlocking nailing is an effective technique used to treat long bone fractures. Recently, biodegradable metals have drawn increased attention as an intramedullary interlocking nailing material. In this study, numerical simulations were implemented to determine whether the degradation rate of magnesium alloy makes it a suitable material for manufacturing biodegradable intramedullary interlocking nails. Mechano-regulatory and bone-remodeling models were used to simulate the fracture healing process, and a surface corrosion model was used to simulate intramedullary rod degradation. The results showed that magnesium alloy intramedullary rods exhibited a satisfactory degradation rate; the fracture healed and callus enhancement was observed before complete dissolution of the intramedullary rod. Delayed magnesium degradation (using surface coating techniques) did not confer a significant advantage over the non-delayed degradation process; immediate degradation also achieved satisfactory healing outcomes. However, delayed degradation had no negative effect on callus enhancement, as it did not cause signs of stress shielding. To avoid risks of individual differences such as delayed union, delayed degradation is recommended. Although the magnesium intramedullary rod did not demonstrate rapid degradation, its ability to provide high fixation stiffness to achieve earlier load bearing was inferior to that of the conventional titanium alloy and stainless steel rods. Therefore, light physiological loads should be ensured during the early stages of healing to achieve bony healing; otherwise, with increased loading and degraded intramedullary rods, the fracture may ultimately fail to heal. Copyright © 2016 Elsevier Ltd. All rights reserved.

  4. TIBIAL SHAFT FRACTURES.

    PubMed

    Kojima, Kodi Edson; Ferreira, Ramon Venzon

    2011-01-01

    The long-bone fractures occur most frequently in the tibial shaft. Adequate treatment of such fractures avoids consolidation failure, skewed consolidation and reoperation. To classify these fractures, the AO/OTA classification method is still used, but it is worthwhile getting to know the Ellis classification method, which also includes assessment of soft-tissue injuries. There is often an association with compartmental syndrome, and early diagnosis can be achieved through evaluating clinical parameters and constant clinical monitoring. Once the diagnosis has been made, fasciotomy should be performed. It is always difficult to assess consolidation, but the RUST method may help in this. Radiography is assessed in two projections, and points are scored for the presence of the fracture line and a visible bone callus. Today, the dogma of six hours for cleaning the exposed fracture is under discussion. It is considered that an early start to intravenous antibiotic therapy and the lesion severity are very important. The question of early or late closure of the lesion in an exposed fracture has gone through several phases: sometimes early closure has been indicated and sometimes late closure. Currently, whenever possible, early closure of the lesion is recommended, since this diminishes the risk of infection. Milling of the canal when the intramedullary nail is introduced is still a controversial subject. Despite strong personal positions in favor of milling, studies have shown that there may be some advantage in relation to closed fractures, but not in exposed fractures.

  5. Proximal Tibial Bone Graft

    MedlinePlus

    ... All Site Content AOFAS / FootCareMD / Treatments Proximal Tibial Bone Graft Page Content What is a bone graft? Bone grafts may be needed for various ... the proximal tibia. What is a proximal tibial bone graft? Proximal tibial bone graft (PTBG) is a ...

  6. Intramedullary nailing of humeral shaft fractures.

    PubMed

    Pickering, Robert M; Crenshaw, Andrew H; Zinar, Daniel M

    2002-01-01

    The development of interlocking humeral nail systems has greatly broadened the indications for nailing of humeral shaft fracture. Rotational control is better than with earlier nail systems, and most nails have an oblong distal hole that allows axial loading of the fracture site with muscle contraction. When nailing is done with closed technique, loss of the fracture hematoma and periosteal stripping are avoided. Even when open reduction is required, periosteal stripping can be kept to a minimum. Surgical wounds are smaller, even when open reduction is necessary, and when closed nailing is done, bone grafting is unnecessary. Intramedullary nails are ideal for segmental fractures, pathologic fractures, and fractures in osteopenic bone. Because the arm usually is not a weight-bearing extremity, hardware failure is rare and union rates are equivalent to those of compression plate and screw fixation. Compression plates and external fixation certainly have their place for some fracture patterns and for severe wounds that are unsuitable for intramedullary nailing. The surgeon should be well versed in all three techniques and should be able to rapidly choose among these, depending upon the fracture pattern, skin wound, associated injuries, and overall condition of the patient.

  7. EPR spectroscopic investigation of psoriatic finger nails.

    PubMed

    Nakagawa, Kouichi; Minakawa, Satoko; Sawamura, Daisuke

    2013-11-01

    Nail lesions are common features of psoriasis and found in almost half of the patients. However, there is no feasible spectroscopic method evaluating changes and severity of nail psoriasis. EPR (electron paramagnetic resonance) might be feasible for evaluating nail conditions in the patients of psoriasis. Finger nails of five cases with nail psoriasis, (three females and two males) were examined. Nail samples were subjected to the EPR assay. The small piece of the finger nail (1.5 × 5 mm(2)) was incubated in ~50 μM 5-DSA (5-doxylstearic acid) aqueous solutions for about 60 min at 37°C. After rinsing and wiping off the excess 5-DSA solution, the nail samples were measured by EPR. EPR spectra were analyzed using the intensity ratio (Fast/Slow) of the two motions at the peaks of the lower magnetic field. We observed two distinguishable sites on the basis of the EPR results. In addition, the modern EPR calculation was performed to analyze the spectra obtained. The nail psoriasis-related region is 2~3 times higher than that of the control. The present EPR results show that there are two distinguishable sites in the nail. In the case of nail psoriasis, the fragile components are 2~3 times more than those of the control. Thus, the EPR method is thought to be a novel and reliable method of evaluating the nail psoriasis. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  8. Biomechanical investigation of a novel ratcheting arthrodesis nail.

    PubMed

    McCormick, Jeremy J; Li, Xinning; Weiss, Douglas R; Billiar, Kristen L; Wixted, John J

    2010-10-14

    Knee or tibiotalocalcaneal arthrodesis is a salvage procedure, often with unacceptable rates of nonunion. Basic science of fracture healing suggests that compression across a fusion site may decrease nonunion. A novel ratcheting arthrodesis nail designed to improve dynamic compression is mechanically tested in comparison to existing nails. A novel ratcheting nail was designed and mechanically tested in comparison to a solid nail and a threaded nail using sawbones models (Pacific Research Laboratories, Inc.). Intramedullary nails (IM) were implanted with a load cell (Futek LTH 500) between fusion surfaces. Constructs were then placed into a servo-hydraulic test frame (Model 858 Mini-bionix, MTS Systems) for application of 3 mm and 6 mm dynamic axial displacement (n = 3/group). Load to failure was also measured. Mean percent of initial load after 3-mm and 6-mm displacement was 190.4% and 186.0% for the solid nail, 80.7% and 63.0% for the threaded nail, and 286.4% and 829.0% for the ratcheting nail, respectively. Stress-shielding (as percentage of maximum load per test) after 3-mm and 6-mm displacement averaged 34.8% and 28.7% (solid nail), 40.3% and 40.9% (threaded nail), and 18.5% and 11.5% (ratcheting nail), respectively. In the 6-mm trials, statistically significant increase in initial load and decrease in stress-shielding for the ratcheting vs. solid nail (p = 0.029, p = 0.001) and vs. threaded nail (p = 0.012, p = 0.002) was observed. Load to failure for the ratcheting nail; 599.0 lbs, threaded nail; 508.8 lbs, and solid nail; 688.1 lbs. With significantly increase of compressive load while decreasing stress-shielding at 6-mm of dynamic displacement, the ratcheting mechanism in IM nails may clinically improve rates of fusion.

  9. Biomechanical investigation of a novel ratcheting arthrodesis nail

    PubMed Central

    2010-01-01

    Background Knee or tibiotalocalcaneal arthrodesis is a salvage procedure, often with unacceptable rates of nonunion. Basic science of fracture healing suggests that compression across a fusion site may decrease nonunion. A novel ratcheting arthrodesis nail designed to improve dynamic compression is mechanically tested in comparison to existing nails. Methods A novel ratcheting nail was designed and mechanically tested in comparison to a solid nail and a threaded nail using sawbones models (Pacific Research Laboratories, Inc.). Intramedullary nails (IM) were implanted with a load cell (Futek LTH 500) between fusion surfaces. Constructs were then placed into a servo-hydraulic test frame (Model 858 Mini-bionix, MTS Systems) for application of 3 mm and 6 mm dynamic axial displacement (n = 3/group). Load to failure was also measured. Results Mean percent of initial load after 3-mm and 6-mm displacement was 190.4% and 186.0% for the solid nail, 80.7% and 63.0% for the threaded nail, and 286.4% and 829.0% for the ratcheting nail, respectively. Stress-shielding (as percentage of maximum load per test) after 3-mm and 6-mm displacement averaged 34.8% and 28.7% (solid nail), 40.3% and 40.9% (threaded nail), and 18.5% and 11.5% (ratcheting nail), respectively. In the 6-mm trials, statistically significant increase in initial load and decrease in stress-shielding for the ratcheting vs. solid nail (p = 0.029, p = 0.001) and vs. threaded nail (p = 0.012, p = 0.002) was observed. Load to failure for the ratcheting nail; 599.0 lbs, threaded nail; 508.8 lbs, and solid nail; 688.1 lbs. Conclusion With significantly increase of compressive load while decreasing stress-shielding at 6-mm of dynamic displacement, the ratcheting mechanism in IM nails may clinically improve rates of fusion. PMID:20942976

  10. Free flap reconstructions of tibial fractures complicated after internal fixation.

    PubMed

    Nieminen, H; Kuokkanen, H; Tukiainen, E; Asko-Seljavaara, S

    1995-04-01

    The cases of 15 patients are presented where microvascular soft-tissue reconstructions became necessary after internal fixation of tibial fractures. Primarily, seven of the fractures were closed. Eleven fractures had originally been treated by open reduction and internal fixation using plates and screws, and four by intramedullary nailing. All of the patients suffered from postoperative complications leading to exposure of the bone or fixation material. The internal fixation material was removed and radical revision of dead and infected tissue was carried out in all cases. Soft tissue reconstruction was performed using a free microvascular muscle flap (11 latissimus dorsi, three rectus abdominis, and one gracilis). In eight cases the nonunion of the fracture indicated external fixation. The microvascular reconstruction was successful in all 15 patients. In one case the recurrence of deep infection finally indicated a below-knee amputation. In another case, chronic infection with fistulation recurred postoperatively. After a mean follow-up of 26 months the soft tissue coverage was good in all the remaining 13 cases. All the fractures united. Microvascular free muscle flap reconstruction of the leg is regarded as a reliable method for salvaging legs with large soft-tissue defects or defects in the distal leg. If after internal fixation of the tibial fracture the osteosynthesis material or fracture is exposed, reconstruction of the soft-tissue can successfully be performed by free flap transfer. By radical revision, external fixation, bone grafting, and a free flap the healing of the fracture can be achieved.

  11. The effect of plate position and size on tibial slope in high tibial osteotomy: a cadaveric study.

    PubMed

    Rubino, L Joseph; Schoderbek, Robert J; Golish, S Raymond; Baumfeld, Joshua; Miller, Mark D

    2008-01-01

    Opening wedge high tibial osteotomies are performed for degenerative changes and varus. Opening wedge osteotomies can change proximal tibial slope in the sagittal plane, possibly imparting stability in the ACL-deficient knee. The aim of this study was to assess the effect of plate position and size on change in tibial slope. Eight cadaveric knees underwent opening wedge high tibial osteotomy with Puddu plates of each different size. Plates were placed anterior, central, and posterior for each size used. Lateral radiographs were obtained. Tibial slope was measured and compared with baseline slope. Tibial slope was affected by plate position (P < 0.05) and size (P < 0.001). Smaller, posterior plates had less effect on tibial slope. However, anterior and central plates increased tibial slope over all plate sizes (P < 0.05). This study found that tibial slope increases with opening wedge high tibial osteotomy. Larger corrections and anterior placement of the plate are associated with larger increases in slope.

  12. Influence of the intramedullary nail preparation method on nail's mechanical properties and degradation rate.

    PubMed

    Morawska-Chochół, Anna; Chłopek, Jan; Szaraniec, Barbara; Domalik-Pyzik, Patrycja; Balacha, Ewa; Boguń, Maciej; Kucharski, Rafael

    2015-06-01

    When it comes to the treatment of long bone fractures, scientists are still investigating new materials for intramedullary nails and different manufacturing methods. Some of the most promising materials used in the field are resorbable polymers and their composites, especially since there is a wide range of potential manufacturing and processing methods. The aim of this work was to select the best manufacturing method and technological parameters to obtain multiphase, and multifunctional, biodegradable intramedullary nails. All composites were based on a poly(l-lactide) matrix. Either magnesium alloy wires or carbon and alginate fibres were introduced in order to reinforce the nails. The polylactide matrix was also modified with tricalcium phosphate and gentamicin sulfate. The composite nails were manufactured using three different methods: forming from solution, injection moulding and hot pressing. The effect of each method of manufacturing on mechanical properties and degradation rate of the nails was evaluated. The study showed that injection moulding provides higher uniformity and homogeneity of the particle-modified polylactide matrix, whereas hot pressing favours applying higher volume fractions of fibres and their better impregnation with the polymer matrix. Thus, it was concluded that the fabrication method should be individually selected dependently on the nail's desired phase composition. Copyright © 2015 Elsevier B.V. All rights reserved.

  13. Genetics Home Reference: nonsyndromic congenital nail disorder 10

    MedlinePlus

    ... Nails MalaCards: nail disorder, nonsyndromic congenital, 10 Merck Manual Consumer Version: Deformities, Dystrophies, and Discoloration of the Nails Orphanet: Autosomal recessive nail dysplasia Patient Support ...

  14. Investigation of Human Nail Microstructure with Ultrasound

    NASA Astrophysics Data System (ADS)

    Maeva, A. R.; Bakulin, E. Y.; Denisova, L. A.; Maev, R. Gr.

    Investigation of a human fingernail and the extraction of the data on its microstructure and elastic properties is important in three main aspects. First of all, various diseases of the nail can be differentiated more precisely; second of all, it is possible to non-invasively track during time the effects of a cosmetic product upon the nail; third of all, because various processes in the organism have a strong influence upon the nail plate growth, the monitoring of the nail morphology and its mechanical properties may be used as additional information for the diagnosis of a number of medical disorders, such as systemic sclerosis, psoriasis, chronic hand eczema, anemia etc. The aim of the present study was to carry out a detailed ultrasound investigation in the high-frequency range (25-50 MHz) of a human nail including micro-anatomical structure imaging and ultrasound velocity evaluation, using B-scans obtained with a scanning acoustic microscope. On the images, exact topology of the nail, nail matrix and the underlying bone have been revealed. Additionally, a certain type of inclined internal layering along the nails of some individuals has been found, which was not reported in previous ultrasonic studies of the nail.

  15. Tibial tunnel aperture location during single-bundle posterior cruciate ligament reconstruction: comparison of tibial guide positions.

    PubMed

    Shin, Young-Soo; Han, Seung-Beom; Hwang, Yeok-Ku; Suh, Dong-Won; Lee, Dae-Hee

    2015-05-01

    We aimed to compare posterior cruciate ligament (PCL) tibial tunnel location after tibial guide insertion medial (between the PCL remnant and the medial femoral condyle) and lateral (between the PCL remnant and the anterior cruciate ligament) to the PCL stump as determined by in vivo 3-dimensional computed tomography (3D-CT). Tibial tunnel aperture location was analyzed by immediate postoperative in vivo CT in 66 patients who underwent single-bundle PCL reconstruction, 31 by over-the-PCL and 35 by under-the-PCL tibial guide insertion techniques. Tibial tunnel positions were measured in the medial to lateral and proximal to distal directions of the posterior proximal tibia. The center of the tibial tunnel aperture was located more laterally (by 2.7 mm) in the over-the-PCL group than in the under-the-PCL group (P = .040) and by a relative percentage (absolute value/tibial width) of 3.2% (P = .031). Tibial tunnel positions in the proximal to distal direction, determined by absolute value and relative percentage, were similar in the 2 groups. Tibial tunnel apertures were located more laterally after lateral-to-the-PCL tibial guide insertion than after medial-to-the-PCL tibial guide insertion. There was, however, no significant difference between these techniques in distance from the joint line to the tibial tunnel aperture. Insertion lateral to the PCL stump may result in better placement of the PCL in its anatomic footprint. Level III, retrospective comparative study. Copyright © 2015 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  16. Nail tic disorders: Manifestations, pathogenesis and management.

    PubMed

    Singal, Archana; Daulatabad, Deepashree

    2017-01-01

    Nail tic disorders are classic examples of overlap between the domains of dermatology and psychiatry. They are examples of body-focused repetitive behaviors in which there is an irresistible urge or impulse to perform a certain behavior. The behavior is reinforced as it results in some degree of relief and pleasure. Nail tic disorders are common, yet poorly studied and understood. The literature on nail tic disorders is relatively scarce. Common nail tics include nail biting or onychophagia, onychotillomania and the habit tic deformity. Some uncommon and rare nail tic disorders are onychoteiromania, onychotemnomania, onychodaknomania and bidet nails. Onychophagia is chronic nail biting behavior which usually starts during childhood. It is often regarded as a tension reducing measure. Onychotillomania is recurrent picking and manicuring of the fingernails and/or toenails. In severe cases, it may lead to onychoatrophy due to irreversible scarring of the nail matrix. Very often, they occur in psychologically normal children but may sometimes be associated with anxiety. In severe cases, onychotillomania may be an expression of obsessive-compulsive disorders. Management of nail tic disorders is challenging. Frequent applications of distasteful topical preparations on the nail and periungual skin can discourage patients from biting and chewing their fingernails. Habit-tic deformity can be helped by bandaging the digit daily with permeable adhesive tape. Fluoxetine in high doses can be helpful in interrupting these compulsive disorders in adults. For a complete diagnosis and accurate management, it is imperative to assess the patient's mental health and simultaneously treat the underlying psychiatric comorbidity, if any.

  17. The nail and hair in forensic science.

    PubMed

    Daniel, C Ralph; Piraccini, Bianca Maria; Tosti, Antonella

    2004-02-01

    Drugs, chemicals, and biological substances accumulate and are stored in hair and nails where they can be detected and measured. Advantages of analyzing hair and nail samples also include their easy and non-invasive collection, the small sample size required for analysis, and their easy storage at room temperature. We report 3 examples of heavy metal poisoning diagnosed because of the hair or nail symptoms. Drugs and toxins that can be detected in hair and nails are reviewed and the application of hair/nail analysis in general and in forensic medicine is discussed.

  18. Review of end grain nail withdrawal research

    Treesearch

    Douglas R. Rammer; Samuel L. Zelinka

    2004-01-01

    This study reviewed the literature on static and impact withdrawal of nails driven into the end grain of wood members. From this, an empirical relationship was created relating the specific gravity of the wood, the diameter of the nail, and the depth of penetration of the nail to the static withdrawal capacity of nails driven into the wood and withdrawn immediately....

  19. Rap system of stress stimulation can promote bone union after lower tibial bone fracture: a clinical research.

    PubMed

    Yao, Jian-fei; Shen, Jia-zuo; Li, Da-kun; Lin, Da-sheng; Li, Lin; Li, Qiang; Qi, Peng; Lian, Ke-jian; Ding, Zhen-qi

    2012-01-01

    Lower tibial bone fracture may easily cause bone delayed union or nonunion because of lacking of dynamic mechanical load. Research Group would design a new instrument as Rap System of Stress Stimulation (RSSS) to provide dynamic mechanical load which would promote lower tibial bone union postoperatively. This clinical research was conducted from January 2008 to December 2010, 92 patients(male 61/female 31, age 16-70 years, mean 36.3 years) who suffered lower tibial bone closed fracture were given intramedullary nail fixation and randomly averagely separated into experimental group and control group(according to the successively order when patients went for the admission procedure). Then researchers analysed the clinical healing time, full weight bearing time, VAS (Visual Analogue Scales) score and callus growth score of Lane-Sandhu in 3,6,12 months postoperatively. The delayed union and nonunion rates were compared at 6 and 12 months separately. All the 92 patients had been followed up (mean 14 months). Clinical bone healing time in experimental group was 88.78±8.80 days but control group was 107.91±9.03 days. Full weight bearing time in experimental group was 94.07±9.81 days but control group was 113.24±13.37 days respectively (P<0.05). The delayed union rate in 6 months was 4.3% in experimental group but 10.9% in control group(P<0.05). The nonunion rate in 12 months was 6.5% in experimental group but 19.6% in control group(P<0.05). In 3, 6, 12 months postoperatively, VAS score and Lane-Sandhu score in experimental group had more significantly difference than them in control group. RSSS can intermittently provide dynamic mechanical load and stimulate callus formation, promote lower tibial bone union, reduce bone delayed union or nonunion rate. It is an adjuvant therapy for promoting bone union after lower tibial bone fracture.

  20. [Intramedullary nailing of the distal tibia illustrated with the Expert(TM) tibia nail].

    PubMed

    El Attal, R; Hansen, M; Rosenberger, R; Smekal, V; Rommens, P M; Blauth, M

    2011-12-01

    Restoration of axis, length, and rotation of the lower leg. Sufficient primary stability of the osteosynthesis for functional aftercare and to maintain joint mobility. Good bony healing in closed and open fractures. Closed and open fractures of the tibia and complete lower leg fractures distal to the isthmus (AO 42), extraarticular fractures of the distal tibia (AO 43 A1/A2/A3), segmental fractures of the tibia with a fracture in the distal tibia, and certain intraarticular fractures of the distal tibia without impression of the joint line with the use of additional implants (AO 43 C1) Patient in reduced general condition (e.g., bed ridden), flexion of the knee of less than 90°, patients with knee arthroplasty of the affected leg, infection in the area of the nail's insertion, infection of the tibial cavity, complex articular fractures of the proximal or distal tibia with joint depression. Closed reduction of the fracture preferably on a fracture table or using a distractor or an external fixation frame. If necessary, use pointed reduction clamps or sterile drapery. In some cases, additional implants like percutaneous small fragment screws, poller screws or k-wires are helpful. Open reduction is rarely necessary and must be avoided. Opening of the proximal tibia in line with the medullary canal. Canulated insertion of the Expert(TM) tibia nail (ETN; Synthes GmbH, Oberdorf, Switzerland) with reaming of the medullary canal. Control of axis, length, and rotation. Distal interlocking with the radiolucent drill and proximal interlocking with the targeting device. Immediate mobilization of ankle and knee joint. Mobilization with 20 kg weight-bearing with crutches. X-ray control 6 weeks postoperatively and increased weight-bearing depending on the fracture status. In cases with simple fractures, good bony contact, or transverse fracture pattern, full weight-bearing at the end of week 6 is targeted. Between July 2004 and May 2005, 180 patients were included in a

  1. Tibial bone fractures occurring after medioproximal tibial bone grafts for oral and maxillofacial reconstruction.

    PubMed

    Kim, Il-Kyu; Cho, Hyun-Young; Pae, Sang-Pill; Jung, Bum-Sang; Cho, Hyun-Woo; Seo, Ji-Hoon

    2013-12-01

    Oral and maxillofacial defects often require bone grafts to restore missing tissues. Well-recognized donor sites include the anterior and posterior iliac crest, rib, and intercalvarial diploic bone. The proximal tibia has also been explored as an alternative donor site. The use of the tibia for bone graft has many benefits, such as procedural ease, adequate volume of cancellous and cortical bone, and minimal complications. Although patients rarely complain of pain, swelling, discomfort, or dysfunction, such as gait disturbance, both patients and surgeons should pay close attention to such after effects due to the possibility of tibial fracture. The purpose of this study is to analyze tibial fractures that occurring after osteotomy for a medioproximal tibial graft. An analysis was intended for patients who underwent medioproximal tibial graft between March 2004 and December 2011 in Inha University Hospital. A total of 105 subjects, 30 females and 75 males, ranged in age from 17 to 78 years. We investigated the age, weight, circumstance, and graft timing in relation to tibial fracture. Tibial fractures occurred in four of 105 patients. There were no significant differences in graft region, shape, or scale between the fractured and non-fractured patients. Patients who undergo tibial grafts must be careful of excessive external force after the operation.

  2. [Locked plating with minimally invasive percutaneous plate osteosynthesis versus intramedullary nailing of distal extra-articular tibial fracture: a retrospective study].

    PubMed

    Yao, Qi; Ni, Jie; Peng, Li-bin; Yu, Da-xin; Yuan, Xiao-ming

    2013-12-17

    To compare the efficacies of minimally invasive plate osteosynthesis (MIPPO) and interlocking intramedullary nailing (IMN) in the treatment of extra-articular fractures of distal tibia. Retrospective reviews were conducted for 126 patients with extra-articular distal tibia fractures. Treatment was either MIPPO (n = 61) or IMN (n = 65). The outcomes were assessed by comparing operating duration, time to union, the last follow-up American Orthopedic Foot and Ankle Society (AOFAS) score and complication rate. The average follow-up period was 23.7 (12-53) months. In the minimally invasive plate osteosynthesis group, there were deep infections (n = 2), superficial infections (n = 5), delayed union (n = 2), malunion (n = 2) and knee joint pain (n = 10) were observed. In addition, the average operating duration (85.9 ± 18.9 min), average time to union (17.3 ± 3.8 weeks) and average AOFAS (83.2 ± 11.9) were analyzed. In the interlocking intramedullary nailing group, there were delayed union (n = 3), malunion (n = 12) and knee joint pain (n = 22). And the average operating duration (83.3 ± 15.7 min), average time to union (16.5 ± 3.1 weeks) and average AOFAS (84.9 ± 12.0) were analyzed. No statistical significance existed in operating duration, time to union and the last follow-up AOFAS between two groups (P > 0.05). However, the rates of malformation and knee joint pain were higher in the intramedullary nail group than those in the plate group. And the difference was statistically significant (P = 0.015, P = 0.025). Both MIPPO and IMN are effective for extra-articular fractures of distal tibia. However, the former has the advantage of lowers rate of malformation and knee joint pain. Therefore a surgeon should consider the degree of injury while managing extra-articular fracture of distal tibia.

  3. Intramedullary nailing: experience in 427 patients.

    PubMed

    Lambiris, E; Tyllianakis, M; Megas, P; Panagiotopoulos, E

    1996-01-01

    In the Orthopaedic Department in Patras University 427 intramedullary nailings in the lower limbs were performed between 1989 and 1994 and retrospectively reviewed to evaluate the range of complications. One hundred and seventy-two were nailings of the femur; 80 gamma nails mainly for subtrochanteric and intertrochanteric with subtrochanteric extension fractures were included, (total 252/59%); 175 (41%) were nailings of the tibia. Union was achieved in all case. Overall the complication rate in this series was 3.3% (14 cases) and included infection (4 cases), neuropraxia (2 cases), implant failure (5 cases), limb length deficiency (2 cases) and malrotation (1 case).

  4. Dermoscopic features of nail psoriasis treated with biologics.

    PubMed

    Hashimoto, Yuki; Uyama, Miki; Takada, Yuko; Yoshida, Kenji; Ishiko, Akira

    2017-05-01

    Although psoriatic nail lesions are small, they cause considerable discomfort for patients and adversely affect quality of life. Few studies have evaluated the dermoscopic features of psoriatic nails. The aim of this study was to clarify the dermoscopic features of nail psoriasis and identify those that reflect psoriatic activity. During biologic treatment of psoriasis, six patients with psoriatic nails twice underwent dermoscopic examination, with an interval of 17-42 weeks. We used the modified Nail Psoriasis Severity Index score and Psoriasis Area and Severity Index score to identify and assess dermoscopic features. We identified 10 dermoscopic findings, of which disappearance of diffuse scaling of the nail plate, transverse step-like notches and splinter hemorrhages of the nail bed, and appearance of erythematous borders of the onycholytic area were associated with improvement in Psoriasis Area and Severity Index score. Dermoscopy can detect nail changes during psoriasis treatment and should be used to evaluate treatment success. © 2017 Japanese Dermatological Association.

  5. Tibial plateau fracture following gracilis-semitendinosus anterior cruciate ligament reconstruction: The tibial tunnel stress-riser.

    PubMed

    Sundaram, R O; Cohen, D; Barton-Hanson, N

    2006-06-01

    Tibial plateau fractures following anterior cruciate ligament (ACL) reconstruction are extremely rare. This is the first reported case of a tibial plateau fracture following four-strand gracilis-semitendinosus autograft ACL reconstruction. The tibial tunnel alone may behave as a stress riser which can significantly reduce bone strength.

  6. Nail gun injuries among construction workers.

    PubMed

    Dement, John M; Lipscomb, Hester; Li, Leiming; Epling, Carol; Desai, Tejas

    2003-05-01

    Pneumatic nail guns greatly increase worker productivity and are extensively used in wood frame building construction, with especially high use in residential construction. One surveillance report of nail gun injuries in Washington State has been published; however, other literature consists largely of case reports and case series in trauma journals. The major objective of the current study was to investigate the occurrence of nail gun-associated injuries among construction workers and to identify preventable work-related factors associated with these injuries. Nail gun-related injuries occurring among a cohort of 13,347 carpenters in Ohio who worked union hours during the time period January 1, 1994, until September 30, 1997, were identified by matching the cohort with workers' compensation claims made to the Ohio Bureau of Workers' Compensation. We also analyzed workers' compensation claims for North Carolina Home Builders Association members for the period July 1996-November 1999 to identify nail gun-related injuries. Analyses included stratified analyses of claims by nature and body part injured, calculation of nail gun injury rates, and analyses of free text descriptions of injuries. Overall, nail gun injuries were responsible for 3.9 percent of workers' compensation claims with 8.3 percent to 25.5 percent of claims involving paid lost work time. The overall rate of nail gun injuries (cases per 200,000 work hours) was 0.33 in North Carolina and 0.26 in Ohio, reflecting the greater concentration of wood frame construction workers in the North Carolina population studied. Higher rates of injury were observed for carpenters in North Carolina and among residential carpenters in Ohio. The predominant body part injured was the hands/fingers, with 80 to 89 percent of injuries being nail punctures. Analyses of free text information for puncture injuries found approximately 70 percent of injuries to occur during the framing/sheathing stage of construction. Our data

  7. A quantitative method for measuring forces applied by nail braces.

    PubMed

    Erdogan, Fatma G

    2011-01-01

    Nail bracing is a conservative method used for ingrown nails; however, lack of objective measurements limits its use for various nails. Double-string nail braces with extra metal springs were applied to 12 patients with 21 chronic, thick, and overcurved ingrown nails. Force was measured with a force gauge meter. Treatment was stopped once patients stood on their tiptoes and walked in shoes pain free without braces. A force gauge meter was also used on a model nail to show the forces applied by various nail braces and to compare their pulling forces. After 6 to 10 months of treatment, all of the patients were pain free; 600 to 1,000 centi Newtons of force were applied to the nails. As the width of the nail increased, so did the force. Braces exert more force on larger nails, which may shorten treatment durations. By measuring forces, it may be possible to standardize force and duration of treatment according to variables such as nail thickness, nail width, angle of ingrown nail, and duration of symptoms.

  8. Tibial Tray Thickness Significantly Increases Medial Tibial Bone Resorption in Cobalt-Chromium Total Knee Arthroplasty Implants.

    PubMed

    Martin, J Ryan; Watts, Chad D; Levy, Daniel L; Miner, Todd M; Springer, Bryan D; Kim, Raymond H

    2017-01-01

    Stress shielding is an uncommon complication associated with primary total knee arthroplasty. Patients are frequently identified radiographically with minimal clinical symptoms. Very few studies have evaluated risk factors for postoperative medial tibial bone loss. We hypothesized that thicker cobalt-chromium tibial trays are associated with increased bone loss. We performed a retrospective review of 100 posterior stabilized, fixed-bearing total knee arthroplasty where 50 patients had a 4-mm-thick tibial tray (thick tray cohort) and 50 patients had a 2.7-mm-thick tibial tray (thin tray cohort). A clinical evaluation and a radiographic assessment of medial tibial bone loss were performed on both cohorts at a minimum of 2 years postoperatively. Mean medial tibial bone loss was significantly higher in the thick tray cohort (1.07 vs 0.16 mm; P = .0001). In addition, there were significantly more patients with medial tibial bone loss in the thick tray group compared with the thin tray group (44% vs 10%, P = .0002). Despite these differences, there were no statistically significant differences in range of motion, knee society score, complications, or revision surgeries performed. A thicker cobalt-chromium tray was associated with significantly more medial tibial bone loss. Despite these radiographic findings, we found no discernable differences in clinical outcomes in our patient cohort. Further study and longer follow-up are needed to understand the effects and clinical significance of medial tibial bone loss. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Arthrodesis of the knee: experience with intramedullary nailing.

    PubMed

    Incavo, S J; Lilly, J W; Bartlett, C S; Churchill, D L

    2000-10-01

    Knee arthrodesis using an intramedullary nail has gained acceptance as treatment in difficult cases such as infection after total knee arthroplasty (TKA), neuropathic joint, and obesity. A retrospective review of 22 cases treated at our institution using an intramedullary nail for knee arthrodesis was performed. Deep infection after primary (11) or revision (6) TKA was the most common indication for this procedure. A long intramedullary nail was used in 3 cases, a long nail with a proximal interlocking screw was used in 6 cases, and a customized nail with a valgus bend and a proximal interlocking screw was used in 11 cases. A modular knee fusion nail was used in 1 case. Successful fusion occurred in all cases, although 4 patients required additional surgery. Average operative blood loss was 748 mL, and average time to union was 7 months. Shortening of the extremity averaged 3.2 cm. Tibiofemoral alignment was improved by using a customized valgus nail (average, 3.1 valgus; range, 1-5) when compared with a straight nail (average, 0.2 valgus; range, 3 varus to 3 valgus). No patient developed infection in the hip or ankle region as a result of the long intramedullary nail. Intramedullary nailing is an excellent technique for knee arthrodesis in difficult cases. A customized proximal interlocking nail with 5 degrees to 7 degrees of valgus and 5 degrees of anterior angulation improves tibiofemoral alignment and is straightforward to insert or extract should it be necessary. Stability and pain relief are rapid, and the fusion rate is maximized.

  10. [Treatment of calcaneal fractures with a locking nail (C-Nail)].

    PubMed

    Pompach, M; Carda, M; Amlang, M; Zwipp, H

    2016-06-01

    Anatomic reconstruction of the posterior facet by primary stabilization of the calcaneal fracture with a locking nail. All intraarticular calcaneal fractures and unstable two-part fractures independent of the degree of closed/open soft tissue trauma. High perioperative risk, soft tissue infection, beak fracture (type II fracture) and still open apophysis. Anatomic reduction of the posterior facet using a sinus tarsi approach. Reduction and temporary fixation of the sustentacular, tuberosity, and anterior process fragments with 1.8-2.0 mm Kirschner wires. Thereafter, the C-Nail (calcaneus nail) is introduced with its guiding device stabilizing the sustentacular, tuberostity, and anterior process fragments through its three guiding arms with 6 or 7 locking screws. Passive and active motion starts on postoperative day 2. Lymph drains help reduce swelling. Partial weightbearing with 20 kg for 6-8 weeks in the patient's own shoes is recommended. X‑ray controls are done at 4 and 8 weeks as well as after 6 and 12 months. A total of 107 calcaneal fractures treated with the C-Nail between 2011 and 2014 were evaluated according to the AOFAS score 6 months and 1 year after surgery. The measured values were on average 93.0 (range 65-100) points at 6 months and 94.1 (range 75-100) points 12 months after the surgery. Böhler's angle with initial traumatic values of 6.2° (-30 to +13°) improved postoperatively to 31.8°, after 3 months slightly decreased to 29.6°, and after 12 months to 28.3°. There were 2 cases of superficial wound necrosis (1.9 %) and 1 case a deep infection (0.93 %) with need of early C-Nail removal.

  11. ACL double-bundle reconstruction with one tibial tunnel provides equal stability compared to two tibial tunnels.

    PubMed

    Drews, Björn Holger; Seitz, Andreas Martin; Huth, Jochen; Bauer, Gerhard; Ignatius, Anita; Dürselen, Lutz

    2017-05-01

    The purpose of this study was to investigate whether an anterior cruciate ligament (ACL) double-bundle reconstruction with one tibial tunnel displays the same in vitro stability as a conventional double-bundle reconstruction with two tibial tunnels when using the same tensioning protocol. In 11 fresh-frozen cadaveric knees, ACL double-bundle reconstruction with one and two tibial tunnels was performed. The two grafts were tightened using 80 N in different flexion angles (anteromedial-bundle at 60° and posterolateral-bundle at 15°). Anterior tibial translation (134 N) and translation with combined rotatory and valgus loads (10 Nm valgus stress and 4 Nm internal tibial torque) were determined at 0°, 30°, 60° and 90° flexion. Measurements were taken in intact ACL, resected ACL, three-tunnel reconstruction and four-tunnel reconstruction. Additionally, the tension on the grafts was determined. Student's t test was performed for statistical analysis of the related samples. Significance was set at p < 0.017 according to Bonferroni correction. The two reconstructive techniques displayed no significant differences in comparison with the intact ACL in anterior tibial translation at 0°, 60° and 90° of flexion. The same results were obtained for the anterior tibial translation with a combined rotatory load at 60° and 90°. When directly comparing both reconstructive techniques, there were no significant differences for the anterior tibial translation and combined rotatory load at all flexion angles. The measured tension on grafts displayed similar load sharing between both bundles. Except at full extension, both grafts displayed a significantly different tension increase under anterior tibial translation for both techniques (p = 0.0086). Tightening both bundles in ACL double-bundle reconstruction with one or two tibial tunnels in different flexion angles achieved comparable restoration of stability, although there was different load sharing on the bundles

  12. Cranial tibial wedge osteotomy: a technique for eliminating cranial tibial thrust in cranial cruciate ligament repair.

    PubMed

    Slocum, B; Devine, T

    1984-03-01

    Cranial tibial wedge osteotomy, surgical technique for cranial cruciate ligament rupture, was performed on 19 stifles in dogs. This procedure leveled the tibial plateau, thus causing weight-bearing forces to be compressive and eliminating cranial tibial thrust. Without cranial tibial thrust, which was antagonistic to the cranial cruciate ligament and its surgical reconstruction, cruciate ligament repairs were allowed to heal without constant loads. This technique was meant to be used as an adjunct to other cranial cruciate ligament repair techniques.

  13. Tibiotalocalcaneal Arthrodesis Nails: A Comparison of Nails With and Without Internal Compression.

    PubMed

    Taylor, James; Lucas, Douglas E; Riley, Aimee; Simpson, G Alex; Philbin, Terrence M

    2016-03-01

    Hindfoot arthrodesis with tibiotalocalcaneal (TTC) intramedullary nails is used commonly when treating ankle and subtalar arthritis and other hindfoot pathology. Adequate compression is paramount to avoid nonunion and fatigue fracture of the hardware. Arthrodesis systems with internal compression have demonstrated superior compression to systems relying on external methods. This study examined the speed of union with TTC fusion nails with internal compression over nails without internal compression. A retrospective review was performed identifying nail type and time to union of the subtalar joint (STJ) and tibiotalar joint (TTJ). A total of 198 patients were included from 2003 to 2011. The median time to STJ fusion without internal compression was 104 days compared to 92 days with internal compression (P = .044). The median time to TTJ fusion without internal compression was 111 days compared to 93 days with internal compression (P = .010). Adjusting for diabetes, there was no significant difference in fusion speed with or without internal compression for the STJ (P = .561) or TTJ (P = .358). Nonunion rates were 24.5% for the STJ and 17.0% for the TTJ with internal compression, and 43.4% for the STJ and 42.1% for the TTJ without internal compression. This difference remained statistically significant after adjusting for diabetes for the TTJ (P = .001) but not for the STJ (P = .194). The intramedullary hindfoot arthrodesis nail was a viable treatment option in degenerative joint disease of the TTC joint. There appeared to be an advantage using systems with internal compression; however, there was no statistically significant difference after controlling for diabetes. Level III, retrospective comparative series. © The Author(s) 2015.

  14. Effect of Tibial Plateau Levelling Osteotomy on Cranial Tibial Subluxation in the Feline Cranial Cruciate Deficient Stifle Joint: An Ex Vivo Experimental Study.

    PubMed

    Bilmont, A; Retournard, M; Asimus, E; Palierne, S; Autefage, A

    2018-06-11

     This study evaluated the effects of tibial plateau levelling osteotomy on cranial tibial subluxation and tibial rotation angle in a model of feline cranial cruciate ligament deficient stifle joint.  Quadriceps and gastrocnemius muscles were simulated with cables, turnbuckles and a spring in an ex vivo limb model. Cranial tibial subluxation and tibial rotation angle were measured radiographically before and after cranial cruciate ligament section, and after tibial plateau levelling osteotomy, at postoperative tibial plateau angles of +5°, 0° and -5°.  Cranial tibial subluxation and tibial rotation angle were not significantly altered after tibial plateau levelling osteotomy with a tibial plateau angle of +5°. Additional rotation of the tibial plateau to a tibial plateau angle of 0° and -5° had no significant effect on cranial tibial subluxation and tibial rotation angle, although 2 out of 10 specimens were stabilized by a postoperative tibial plateau angle of -5°. No stabilization of the cranial cruciate ligament deficient stifle was observed in this model of the feline stifle, after tibial plateau levelling osteotomy.  Given that stabilization of the cranial cruciate ligament deficient stifle was not obtained in this model, simple transposition of the tibial plateau levelling osteotomy technique from the dog to the cat may not be appropriate. Schattauer GmbH Stuttgart.

  15. Nail psoriasis masqueraded by secondary infection with Rhodotorula mucilaginosa.

    PubMed

    Martini, K; Müller, H; Huemer, H P; Höpfl, R

    2013-11-01

    A 38-year-old man presented with whitish nail changes on all fingers as the sole symptom. The condition had developed within a few days and led to dystrophy of the proximal part of the nail plates. As microscopic examination of nail scrapings demonstrated budding hyphae and the patient working as a teacher reported frequent use of a wet sponge, antifungal therapy was initiated. Subsequent cultures and molecular typing identified Rhodotorula mucilaginosa (formerly R. rubra). This environmental yeast was repeatedly isolated despite of therapy with itraconazole. As no improvement was achieved and testing of the biological activity of the fungus revealed only marginal keratolytic activity, it was considered as a coloniser of a destructed nail matrix. Finally, a biopsy of the nail bed confirmed the diagnosis of nail psoriasis, which rapidly responded to treatment with acitretin and topical calcipotriol/betamethasone cream. Fungal growth in destructed nails masqueraded the underlying disease and may have triggered the psoriatic nail reaction. © 2013 Blackwell Verlag GmbH.

  16. Heat profiles of laser-irradiated nails

    NASA Astrophysics Data System (ADS)

    Paasch, Uwe; Nenoff, Pietro; Seitz, Anna-Theresa; Wagner, Justinus A.; Kendler, Michael; Simon, Jan C.; Grunewald, Sonja

    2014-01-01

    Onychomycosis is a worldwide problem with no tendency for self-healing, and existing systemic treatments achieve disease-free nails in only 35 to 76% of cases. Recently, treatment of nail fungus with a near-infrared laser has been introduced. It is assumed that fungal eradication is mediated by local heat. To investigate if laser treatment has the potential to eradicate fungal hyphae and arthrospores, laser heat application and propagation needs to be studied in detail. This study aimed to measure nail temperatures using real-time videothermography during laser irradiation. Treatment was performed using 808- and 980-nm linear scanning diode lasers developed for hair removal, enabling contact-free homogeneous irradiation of a human nail plate in one pass. Average and peak temperatures increased pass by pass, while the laser beam moved along the nail plates. The achieved mean peak temperatures (808 nm: 74.1 to 112.4°C, 980 nm: 45.8 to 53.5°C), as well as the elevation of average temperatures (808 nm: 29.5 to 38.2°C, 980 nm: 27.1 to 32.6°C) were associated with pain that was equivalent to that of hair removal procedures and was not significantly different for various wavelengths. The linear scanning laser devices provide the benefits of contact-free homogeneous heating of the human nail while ensuring adequate temperature rises.

  17. Heat profiles of laser-irradiated nails.

    PubMed

    Paasch, Uwe; Nenoff, Pietro; Seitz, Anna-Theresa; Wagner, Justinus A; Kendler, Michael; Simon, Jan C; Grunewald, Sonja

    2014-01-01

    Onychomycosis is a worldwide problem with no tendency for self-healing, and existing systemic treatments achieve disease-free nails in only 35 to 76% of cases. Recently, treatment of nail fungus with a near-infrared laser has been introduced. It is assumed that fungal eradication is mediated by local heat. To investigate if laser treatment has the potential to eradicate fungal hyphae and arthrospores, laser heat application and propagation needs to be studied in detail. This study aimed to measure nail temperatures using real-time videothermography during laser irradiation. Treatment was performed using 808- and 980-nm linear scanning diode lasers developed for hair removal, enabling contact-free homogeneous irradiation of a human nail plate in one pass. Average and peak temperatures increased pass by pass, while the laser beam moved along the nail plates. The achieved mean peak temperatures (808 nm: 74.1 to 112.4°C, 980 nm: 45.8 to 53.5°C), as well as the elevation of average temperatures (808 nm: 29.5 to 38.2°C, 980 nm: 27.1 to 32.6°C) were associated with pain that was equivalent to that of hair removal procedures and was not significantly different for various wavelengths. The linear scanning laser devices provide the benefits of contact-free homogeneous heating of the human nail while ensuring adequate temperature rises.

  18. Nails in Forensic Toxicology: An Update.

    PubMed

    Solimini, Renata; Minutillo, Adele; Kyriakou, Chrystalla; Pichini, Simona; Pacifici, Roberta; Busardo, Francesco Paolo

    2017-01-01

    The analysis of nails as a keratinized matrix to detect drugs or illicit substances has been increasingly used in forensic and clinical toxicology as a complementary test, especially for the specific characteristics of stably accumulating substances for long periods of time. This allows a retrospective investigation of chronic drug abuse, monitoring continuous drug or pharmaceutical use, reveal in utero drug exposure or environmental exposures. We herein review the recent literature investigating drug incorporation mechanisms and drug detection in nails for forensic toxicological purposes. Mechanisms of drug incorporation have not yet been fully elucidated. However, some research has lately contributed to a better understanding of how substances are incorporated into nails, suggesting three potential mechanisms of drug incorporation: contamination from sweat, incorporation from nail bed and incorporation from germinal matrix. In addition, numerous methods dealing with the determination of drugs of abuse, medications and alcohol biomarkers in nails have been reported in studies over the years. The latter methods could find application in clinical and forensic toxicology. The studies herein reviewed point out how important it is to standardize and harmonize the methodologies (either pre-analytical or analytical) for nails analysis and the optimization of sampling as well as the development of proficiency testing programs and the determination of cut-off values. Copyright© Bentham Science Publishers; For any queries, please email at epub@benthamscience.org.

  19. Scabies of the nail unit.

    PubMed

    Oh, Susan; Vandergriff, Travis

    2014-10-15

    Scabies limited to the nail unit is quite unusual, but may persist after treatment of crusted scabies. We present a man with a history of crusted scabies that resolved with treatment, but later the patient reported a chronic problem with crumbly, thickened nails, which were found to be harboring scabies mites.

  20. Aging changes in hair and nails

    MedlinePlus

    ... page: //medlineplus.gov/ency/article/004005.htm Aging changes in hair and nails To use the sharing ... you age, your hair and nails begin to change. HAIR CHANGES AND THEIR EFFECTS Hair color change . ...

  1. Clinical features and nail clippings in 52 children with psoriasis.

    PubMed

    Uber, Marjorie; Carvalho, Vânia O; Abagge, Kerstin T; Robl Imoto, Renata; Werner, Betina

    2018-03-01

    Nail clipping, the act of cutting the distal portion of a nail for microscopic analysis, can complement the diagnosis of skin diseases with nail involvement, such as psoriasis. This study aimed to describe histopathologic findings on 81 nails from 52 children and adolescents with skin psoriasis and to determine whether these changes correlated with the severity of skin and nail involvement. Children with psoriasis were enrolled in this cross-sectional study to obtain Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores. The most altered nails were processed using periodic acid-Schiff with diastase staining. Fifty-two patients with a median age of 10.5 years were included. The median Nail Psoriasis Severity Index score of the 20 nails from these patients was 17 (range 3-80). The most common findings were pitting (94.2%), leukonychia (73.0%), and longitudinal ridges (63.5%). Eighty-one nail fragments were collected by clipping. Neutrophils were found in 6 samples (7.6%) and serous lakes in 15 (19%). Median nail plate thickness was 0.3 mm (range 0.1-0.63 mm). Patients whose nails had neutrophils had a higher median PASI score (6.1 vs 2.0, P = .03). Patients whose nails had serous lakes had higher median PASI (5.3 vs 1.9, P = .008) and NAPSI (median 45.0 vs 18.0, P = .006) scores. There seems to be a correlation between some microscopic nail features in children with psoriasis and their PASI and NAPSI scores, so nail clippings from children with suspected psoriasis may help with diagnosis, especially in the presence of neutrophils, and in excluding onychomycosis. © 2018 Wiley Periodicals, Inc.

  2. The Valgus Inclination of the Tibial Component Increases the Risk of Medial Tibial Condylar Fractures in Unicompartmental Knee Arthroplasty.

    PubMed

    Inoue, Shinji; Akagi, Masao; Asada, Shigeki; Mori, Shigeshi; Zaima, Hironori; Hashida, Masahiko

    2016-09-01

    Medial tibial condylar fractures (MTCFs) are a rare but serious complication after unicompartmental knee arthroplasty. Although some surgical pitfalls have been reported for MTCFs, it is not clear whether the varus/valgus tibial inclination contributes to the risk of MTCFs. We constructed a 3-dimensional finite elemental method model of the tibia with a medial component and assessed stress concentrations by changing the inclination from 6° varus to 6° valgus. Subsequently, we repeated the same procedure adding extended sagittal bone cuts of 2° and 10° in the posterior tibial cortex. Furthermore, we calculated the bone volume that supported the tibial component, which is considered to affect stress distribution in the medial tibial condyle. Stress concentrations were observed on the medial tibial metaphyseal cortices and on the anterior and posterior tibial cortices in the corner of cut surfaces in all models; moreover, the maximum principal stresses on the posterior cortex were larger than those on the anterior cortex. The extended sagittal bone cuts in the posterior tibial cortex increased the stresses further at these 3 sites. In the models with a 10° extended sagittal bone cut, the maximum principal stress on the posterior cortex increased as the tibial inclination changed from 6° varus to 6° valgus. The bone volume decreased as the inclination changed from varus to valgus. In this finite element method, the risk of MTCFs increases with increasing valgus inclination of the tibial component and with increased extension of the sagittal cut in the posterior tibial cortex. Copyright © 2016 Elsevier Inc. All rights reserved.

  3. Radiation-free distal locking of intramedullary nails: evaluation of a new electromagnetic computer-assisted guidance system.

    PubMed

    Stathopoulos, Ioannis; Karampinas, Panagiotis; Evangelopoulos, Dimitrios-Stergios; Lampropoulou-Adamidou, Kalliopi; Vlamis, John

    2013-06-01

    Distal locking of intramedullary nails (IMNs) is a difficult part of intramedullary nailing (IMN) that could be time-consuming and expose the surgeon, the surgery personnel and the patient to a considerable amount of radiation as fluoroscopy is usually guiding the procedure. Utilization of electromagnetic fields for that purpose offers an attractive alternative. The SURESHOT™ Distal Targeting System (Smith & Nephew, Inc., Memphis, TN, USA) is a novel commercially available radiation-free aiming system that utilizes computerized electromagnetic field tracking technology for the distal locking of IMNs. In order to evaluate the efficacy of the system we conducted the present study. Nineteen patients (six females-thirteen males, mean age 39.5 years, range 17-85 years) with closed diaphyseal fracture of the femur (eight patients) or the tibia (eleven patients) were treated with IMN using the SURESHOT™ Distal Targeting System for the distal interlocking. All targeting attempts were successful at first try and followed by correct positioning of the screws. Mean time for distal locking of tibial IMNs (two screws) was 219sec (range 200-250sec). Mean time for distal locking of femoral IMNs (two screws) was 249 (range 220-330sec). In the current study the SURESHOT™ Distal Targeting System proved to be accurate, fast and easy to learn. Copyright © 2012 Elsevier Ltd. All rights reserved.

  4. Nail Psoriasis: A Review of Treatment Options.

    PubMed

    Pasch, Marcel C

    2016-04-01

    Nail involvement affects 80-90 % of patients with plaque psoriasis, and is even more prevalent in patients with psoriatic arthritis. This review is the result of a systemic approach to the literature and covers topical, intralesional, conventional systemic, and biologic systemic treatments, as well as non-pharmacological treatment options for nail psoriasis. The available evidence suggests that all anti-tumor necrosis factor-α, anti-interleukin (IL)-17, and anti-IL-12/23 antibodies which are available for plaque psoriasis and psoriatic arthritis are highly effective treatments for nail psoriasis. Conventional systemic treatments, including methotrexate, cyclosporine, acitretin, and apremilast, as well as intralesional corticosteroids, can also be effective treatments for nail psoriasis. Topical treatments, including corticosteroids, calcipotriol, tacrolimus, and tazarotene, have also been shown to have a position in the treatment of nail psoriasis, particularly in mild cases. Finally, non-pharmacological treatment options, including phototherapy, photodynamic therapy, laser therapy, and several radiotherapeutic options, are also reviewed but cannot be advised as first-line treatment options. Another conclusion of this review is that the lack of a reliable core set of outcomes measures for trials in nail psoriasis hinders the interpretation of results, and is urgently needed.

  5. Anatomic tibial component design can increase tibial coverage and rotational alignment accuracy: a comparison of six contemporary designs.

    PubMed

    Dai, Yifei; Scuderi, Giles R; Bischoff, Jeffrey E; Bertin, Kim; Tarabichi, Samih; Rajgopal, Ashok

    2014-12-01

    The aim of this study was to comprehensively evaluate contemporary tibial component designs against global tibial anatomy. We hypothesized that anatomically designed tibial components offer increased morphological fit to the resected proximal tibia with increased alignment accuracy compared to symmetric and asymmetric designs. Using a multi-ethnic bone dataset, six contemporary tibial component designs were investigated, including anatomic, asymmetric, and symmetric design types. Investigations included (1) measurement of component conformity to the resected tibia using a comprehensive set of size and shape metrics; (2) assessment of component coverage on the resected tibia while ensuring clinically acceptable levels of rotation and overhang; and (3) evaluation of the incidence and severity of component downsizing due to adherence to rotational alignment and overhang requirements, and the associated compromise in tibial coverage. Differences in coverage were statistically compared across designs and ethnicities, as well as between placements with or without enforcement of proper rotational alignment. Compared to non-anatomic designs investigated, the anatomic design exhibited better conformity to resected tibial morphology in size and shape, higher tibial coverage (92% compared to 85-87%), more cortical support (posteromedial region), lower incidence of downsizing (3% compared to 39-60%), and less compromise of tibial coverage (0.5% compared to 4-6%) when enforcing proper rotational alignment. The anatomic design demonstrated meaningful increase in tibial coverage with accurate rotational alignment compared to symmetric and asymmetric designs, suggesting its potential for less intra-operative compromises and improved performance. III.

  6. [Tibial periostitis ("medial tibial stress syndrome")].

    PubMed

    Fournier, Pierre-Etienne

    2003-06-01

    Medial tibial stress syndrome is characterised by complaints along the posteromedial tibia. Runners and athletes involved in jumping activities may develop this syndrome. Increased stress to stabilize the foot especially when excessive pronation is present explain the occurrence this lesion.

  7. 78 FR 78382 - Steel Nails From China; Determination

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-26

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1114 (Review)] Steel Nails From China... U.S.C. 1675(c)), that revocation of the antidumping duty order on steel nails from China would be... 2013), entitled Steel Nails from China: Investigation No. 731-TA-1114 (Review). By order of the...

  8. Guidance on maintaining personal hygiene in nail care.

    PubMed

    Malkin, Bridget; Berridge, Pat

    Nail care is important in the maintenance of personal hygiene and is an essential aspect of patient care. Confusion about who should perform nail care for patients has resulted in poor practice and cycles of non-activity. This article provides guidance for nurses on performing routine nail care.

  9. Nail Hygiene

    MedlinePlus

    ... diligently cleaning and trimming fingernails, which may harbor dirt and germs and can contribute to the spread ... of their length, longer fingernails can harbor more dirt and bacteria than short nails, thus potentially contributing ...

  10. Treatment of Nail Psoriasis: Common Concepts and New Trends

    PubMed Central

    Oram, Yasemin; Akkaya, A. Deniz

    2013-01-01

    The lifetime incidence of nail involvement in psoriatic patients is estimated to be 80–90%, and the nails can be affected in 10% to 55% of psoriatic patients. Psoriasis may also solely involve the nails, without any other skin findings, in which the treatment can be more challenging. Nail psoriasis may lead to considerable impairment in quality of life due to aesthetic concerns and more importantly limitations in daily activities resulting from the associated pain, which may be overlooked by the physicians. Several topical and systemic treatment modalities, as well as radiation and light systems, have been used in the treatment of nail psoriasis. In the last decade, the introduction of biologic agents and the utilization of laser systems have brought a new insight into the treatment of nail psoriasis. This paper focuses on the recent advances, as well as the conventional methods, in treating nail psoriasis in adults and children, in reference to an extensive literature search. PMID:23762032

  11. Sarcoidosis: nail dystrophy without underlying bone changes.

    PubMed

    Wakelin, S H; James, M P

    1995-06-01

    Sarcoidosis is a chronic granulomatous disease of unknown origin that affects multiple organs and may present with a variety of skin lesions. Involvement of the nails is rare and almost invariably associated with underlying bone disease. We describe a patient with sarcoid nail dystrophy in whom this diagnosis was confirmed by a proximal nail fold biopsy. Radiologic investigation did not show evidence of an associated bone dystrophy in this case.

  12. Taxane-induced nail changes: Predictors and efficacy of the use of frozen gloves and socks in the prevention of nail toxicity.

    PubMed

    Can, Gulbeyaz; Aydiner, Adnan; Cavdar, Ikbal

    2012-07-01

    The primary endpoint of this study was to determine predictors of taxane-related nail toxicity. The secondary endpoint was to evaluate the efficacy of the use of frozen gloves and socks in the prevention of taxane-related nail toxicity. This descriptive, interventional, cross-sectional study was conducted with 200 patients. The patients were assigned to the frozen gloves/socks intervention group or control group. Frozen gloves/socks were applied only in hourly taxane-based treatments. The Patients Record Forms of the clinic were used in data collection. Nail changes were graded using the NCI Common Toxicity Criteria for each patient and treatment. Logistic regression analysis was performed to predict the factors that affect nail changes. The majority of the patients enrolled in the study were women diagnosed with breast cancer. The two groups were statistically similar for the cancer diagnosis, type and number of taxane cycles administered. Grade 1 nail toxicity was found in 34%, grade 2 in 11%, and grade 3 in 5.5% patients. Taxane-related nail toxicity was higher in patients who were female, had a history of diabetes, received capecitabine in conjunction with docetaxel and had breast or gynecological cancer diagnosis. Nail changes increased with an increase in the number of taxane cycles administered, BMI and severity of treatment-related neuropathy. The multivariate analysis demonstrated that BMI, breast or ovarian cancer diagnosis and the number of taxane cycles administered were the independent factors for this toxicity. No statistically significant difference in nail toxicity incidence and time to occurrence of nail changes was found between the intervention and the control groups. Copyright © 2011 Elsevier Ltd. All rights reserved.

  13. Nail Scabies: An Unusual Presentation Often Overlooked and Mistreated.

    PubMed

    Tempark, Therdpong; Lekwuttikarn, Ramrada; Chatproedprai, Susheera; Wananukul, Siriwan

    2017-04-01

    Nail scabies is an interesting clinical presentation of scabies. Although it is usually found concomitant with characteristic dermatologic manifestations, it may present as an isolated finding in the immunocompromised host. This condition is commonly mistaken with other diseases such as nail dystrophy, nail psoriasis and onychomycosis. We report two cases of unusual nail presentations that provide clues to diagnosis. Also, literature on unusual nail and dermatologic presentations was reviewed to recognize dermatologist consideration for appropriate treatment options. © The Author [2016]. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  14. Close association between metal allergy and nail lichen planus: detection of causative metals in nail lesions.

    PubMed

    Nishizawa, A; Satoh, T; Yokozeki, H

    2013-02-01

    Lichen planus (LP) is a common skin disorder of unknown aetiology that affects the skin, mucous membranes and nails. Although metal allergies have been implicated in the development of oral LP (OLP), the contribution of these allergies to nail LP (NLP) has yet to be studied in detail. To elucidate the link between metal allergy and NLP. We retrospectively analysed 115 LP patients with respect to the contribution of metals to either NLP or OLP. We also attempted to detect the specific metals involved in these nail lesions. Of the 79 patients that received a metal patch test (PT), 24 (30%) were positive for at least one of the metal compounds tested. Notably, the prevalence of positive reactions to metals in the NLP patients was significantly higher as compared with the OLP patients (59% vs. 27%, P < 0.05). Among the 10 PT-positive patients with NLP, improvement of the skin lesions was seen in six of the patients after removal of dental materials containing causative metals or systemic disodium cromoglycate therapy. On the other hand, only 3 of 16 PT-positive patients with OLP exhibited improvement after the removal of dental materials. Causative metals in the dental fillings/braces were detected in the involved nail tissues. This study suggests that metal allergies are more closely associated with NLP vs. OLP, and that deposited metals in the nail apparatus contribute to the development of lichenoid tissue reactions in the nail bed and matrix. © 2012 The Authors. Journal of the European Academy of Dermatology and Venereology © 2012 European Academy of Dermatology and Venereology.

  15. A fatal nail gun injury--an unusual ricochet?

    PubMed

    Nadesan, K

    2000-01-01

    An 18-year-old construction worker suddenly collapsed while handling a power-actuated nail gun and died shortly after. A neat, almost circular puncture wound was found on the front of his left chest. No fire-arm residues were detected on the surrounding skin. The police stated that it was an accidental injury, at a construction site, where a nail fired from a nail gun by the deceased had deflected off the wall and struck him on the front of the chest. Since the entry wound appeared to be a neat hole, and that too on the front of the left chest overlying the heart area, there was reluctance on the part of the pathologist to accept it as an accidental injury due to a ricochet. A visit to the scene, interrogation of witnesses, examination of the alleged tool and post-mortem X-ray of the deceased were undertaken prior to autopsy. A bent nail was found in the heart. The scene visit and the subsequent autopsy revealed that the nail took a roughly circular flightpath after it had struck the wall, all the while travelling with its pointed end directed forward. Within the body too, the nail maintained the same path. Various medicolegal issues are discussed pertaining to nail-gun injuries. The importance of a visit to the scene, examination of the alleged tool, interrogation of witnesses and the X-ray of the body, all prior to autopsy, are emphasized. The conclusion was: accidental death due to the unusual ricochet of a nail.

  16. Soil nailing of a bridge fill embankment : construction report.

    DOT National Transportation Integrated Search

    1991-08-01

    Soil nailing as an alternative lateral earth support method has recently been introduced in Oregon to build the first permanent Soil-Nailed Wall on the State's Highway System. : The soil nailing technique was used for an underpass widening to provide...

  17. [Application of tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty].

    PubMed

    Li, Guoliang; Han, Guangpu; Zhang, Jinxiu; Ma, Shiqiang; Guo, Donghui; Yuan, Fulu; Qi, Bingbing; Shen, Runbin

    2013-07-01

    To explore the application value of self-made tibial mechanical axis locator in tibial extra-articular deformity in total knee arthroplasty (TKA) for improving the lower extremity force line. Between January and August 2012, 13 cases (21 knees) of osteoarthritis with tibial extra-articular deformity were treated, including 5 males (8 knees) and 8 females (13 knees) with an average age of 66.5 years (range, 58-78 years). The disease duration was 2-5 years (mean, 3.5 years). The knee society score (KSS) was 45.5 +/- 15.5. Extra-articular deformities included 1 case of knee valgus (2 knees) and 12 cases of knee varus (19 knees). Preoperative full-length X-ray films of lower extremities showed 10-21 degrees valgus or varus deformity of tibial extra joint. Self-made tibial mechanical axis locator was used to determine and mark coronal tibial mechanical axis under X-ray before TKA, and then osteotomy was performed with extramedullary positioning device according to the mechanical axis marker.' All incisions healed by first intention, without related complications of infection and joint instability. All patients were followed up 5-12 months (mean, 8.3 months). The X-ray examination showed < 2 degrees knee deviation angle in the others except 1 case of 2.9 degrees knee deviation angle at 3 days after operation, and the accurate rate was 95.2%. No loosening or instability of prosthesis occurred during follow-up. KSS score was 85.5 +/- 15.0 at last follow-up, showing significant difference when compared with preoperative score (t=12.82, P=0.00). The seft-made tibial mechanical axis locator can improve the accurate rate of the lower extremity force line in TKA for tibia extra-articular deformity.

  18. Maximizing tibial coverage is detrimental to proper rotational alignment.

    PubMed

    Martin, Stacey; Saurez, Alex; Ismaily, Sabir; Ashfaq, Kashif; Noble, Philip; Incavo, Stephen J

    2014-01-01

    Traditionally, the placement of the tibial component in total knee arthroplasty (TKA) has focused on maximizing coverage of the tibial surface. However, the degree to which maximal coverage affects correct rotational placement of symmetric and asymmetric tibial components has not been well defined and might represent an implant design issue worthy of further inquiry. Using four commercially available tibial components (two symmetric, two asymmetric), we sought to determine (1) the overall amount of malrotation that would occur if components were placed for maximal tibial coverage; and (2) whether the asymmetric designs would result in less malrotation than the symmetric designs when placed for maximal coverage in a computer model using CT reconstructions. CT reconstructions of 30 tibial specimens were used to generate three-dimensional tibia reconstructions with attention to the tibial anatomic axis, the tibial tubercle, and the resected tibial surface. Using strict criteria, four commercially available tibial designs (two symmetric, two asymmetric) were placed on the resected tibial surface. The resulting component rotation was examined. Among all four designs, 70% of all tibial components placed in orientation maximizing fit to resection surface were internally malrotated (average 9°). The asymmetric designs had fewer cases of malrotation (28% and 52% for the two asymmetric designs, 100% and 96% for the two symmetric designs; p < 0.001) and less malrotation on average (2° and 5° for the asymmetric designs, 14° for both symmetric designs; p < 0.001). Maximizing tibial coverage resulted in implant malrotation in a large percentage of cases. Given similar amounts of tibial coverage, correct rotational positioning was more likely to occur with the asymmetric designs. Malrotation of components is an important cause of failure in TKA. Priority should be given to correct tibial rotational positioning. This study suggested that it is easier to balance rotation and

  19. High-resolution ultrasonography in assessment of nail-related disorders.

    PubMed

    Singh, R; Bryson, D; Singh, H P; Jeyapalan, K; Dias, J J

    2012-09-01

    Disorders of the nail can pose a diagnostic challenge, and non-invasive imaging is frequently required to clarify diagnosis and delineate anatomy pre-operatively. We explored the use of high-resolution ultrasonography in the assessment of patients with nail disorders attending orthopaedic hand clinics. A search of a university teaching hospital musculoskeletal radiology database identified 36 patients (mean age 54.2 years) where ultrasonography was used to assess nail-related disorders between April 2003 and January 2007. Clinical, surgical and histological findings were correlated in these cases with ultrasound reports. Ultrasound findings correlated with the provisional diagnosis in 20 (61%) of 33 patients and provided a diagnosis in 3 patients where a provisional diagnosis was unavailable. In 7 of the 13 cases where the clinical diagnosis differed from ultrasound findings, a lump originally diagnosed as cystic in origin was shown to be solid on ultrasound. Different nail pathologies showed different characteristics on ultrasonography, including differences in vascularity, echogenicity, changes in nail structure/shape and extension into the nail bed, matrix, fold or evidence of bony erosion. The ultrasound findings correlated with histological analysis and intra-operative assessment in 10 of 15 patients who underwent operative treatment. Ultrasound provides important information on the anatomy of the nail apparatus and can differentiate solid and cystic lesions. It can be used as a diagnostic tool and can therefore help in pre-operative planning of nail-related disorders. In our series ultrasound supported or improved upon the clinical diagnosis in 31 (86%) out of the 36 patients presenting with nail-related disorders.

  20. [A favourable outcome in yellow nail syndrome: role of respiratory physiotherapy].

    PubMed

    Fournier, C; Just, N; Leroy, S; Wallaert, B

    2003-12-01

    The yellow nail syndrome is a rare condition that is easily diagnosed but the nail manifestations are poorly understood. A 51 year old patient presented with a chronic cough. The diagnosis was based on the typical appearance of the nails. The patient had bilateral basal bronchiectasis. Daily physiotherapy with bronchial drainage lead to a progressive improvement in the respiratory symptoms without recourse to antibiotics. Surprisingly the abnormalities of the nails disappeared after 2 years treatment. This observation illustrates the possibility of spontaneous resolution of severe nail abnormalities during the course of the yellow nail syndrome.

  1. Posterior tibial slope in medial opening-wedge high tibial osteotomy: 2-D versus 3-D navigation.

    PubMed

    Yim, Ji Hyeon; Seon, Jong Keun; Song, Eun Kyoo

    2012-10-01

    Although opening-wedge high tibial osteotomy (HTO) is used to correct deformities, it can simultaneously alter tibial slope in the sagittal plane because of the triangular configuration of the proximal tibia, and this undesired change in tibial slope can influence knee kinematics, stability, and joint contact pressure. Therefore, medial opening-wedge HTO is a technically demanding procedure despite the use of 2-dimensional (2-D) navigation. The authors evaluated the posterior tibial slope pre- and postoperatively in patients who underwent navigation-assisted opening-wedge HTO and compared posterior slope changes for 2-D and 3-dimensional (3-D) navigation versions. Patients were randomly divided into 2 groups based on the navigation system used: group A (2-D guidance for coronal alignment; 17 patients) and group B (3-D guidance for coronal and sagittal alignments; 17 patients). Postoperatively, the mechanical axis was corrected to a mean valgus of 2.81° (range, 1°-5.4°) in group A and 3.15° (range, 1.5°-5.6°) in group B. A significant intergroup difference existed for the amount of posterior tibial slope change (Δ slope) pre- and postoperatively (P=.04).Opening-wedge HTO using navigation offers accurate alignment of the lower limb. In particular, the use of 3-D navigation results in significantly less change in the posterior tibial slope postoperatively than does the use of 2-D navigation. Accordingly, the authors recommend the use of 3-D navigation systems because they provide real-time intraoperative information about coronal, sagittal, and transverse axes and guide the maintenance of the native posterior tibial slope. Copyright 2012, SLACK Incorporated.

  2. Removal of a broken trigen intertan intertrochanteric antegrade nail.

    PubMed

    Zheng, Xuan-Lin; Park, Young-Chang; Kim, Sungmin; An, Haemosu; Yang, Kyu-Hyun

    2017-02-01

    Implant breakage is a serious complication after cephalomedullary nailing for unstable intertrochanteric fracture. Failure usually occurs at the lag screw hole in the nail body. On the other hand, lag screw failure is extremely rare and occurs around the nail-lag screw junction. We experienced rare mechanical failure of the Intertan nail, which showed breakage at the lag screw hole and failure of the integrated compression screw underneath the main lag screw. Copyright © 2016 Elsevier Ltd. All rights reserved.

  3. Clinical Evidence for the Relationship between Nail Configuration and Mechanical Forces

    PubMed Central

    Ogawa, Rei

    2014-01-01

    Summary: Mechanobiology is an emerging field of science that focuses on the way physical forces and changes in cell or tissue mechanics contribute to development, physiology, and disease. As nails are always exposed to physical stimulation, mechanical forces may have a particularly pronounced effect on nail configuration and could be involved in the development of nail deformities. However, the role of mechanobiology in nail configuration and deformities has rarely been assessed. This review describes what is currently understood regarding the effect of mechanical force on nail configuration and deformities. On the basis of these observations, we hypothesize that nails have an automatic curvature function that allows them to adapt to the daily upward mechanical forces. Under normal conditions, the upward daily mechanical force and the automatic curvature force are well balanced. However, an imbalance between these 2 forces may cause nail deformation. For example, pincer nails may be caused by the absence of upward mechanical forces or a genetic propensity increase in the automatic curvature force, whereas koilonychias may occur when the upward mechanical force exceeds the automatic curvature force, thereby causing the nail to curve outward. This hypothesis is a new concept that could aid the development of innovative methods to prevent and treat nail deformities. PMID:25289309

  4. Quiz: Nails

    MedlinePlus

    ... you know about your nails? Find out by taking this quiz! About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & Terms of Use Notice of Nondiscrimination Visit the Nemours Web site. Note: All information on KidsHealth® is for educational purposes ...

  5. Pseudoelastic intramedullary nailing for tibio-talo-calcaneal arthrodesis.

    PubMed

    Yakacki, Christopher M; Gall, Ken; Dirschl, Douglas R; Pacaccio, Douglas J

    2011-03-01

    Tibio-talo-calcaneal (TTC) arthrodesis is a procedure to treat severe ankle arthropathy by providing a pain-free and stable fusion. Intramedullary (IM) nails offer a method of internal fixation for TTC arthrodesis by providing compressive stability, as well as shear and torsional rigidity. IM nails have been developed to apply compression to the TTC complex during installation; however, current designs are highly susceptible to a loss of compression when exposed to small amounts of bone resorption and cyclic loading. Nickel titanium (NiTi) is a shape-memory alloy capable of recovering large amounts of deformation via shape-memory or pseudoelasticity. Currently, the next generation of IM nails is being developed to utilize the adaptive, pseudoelastic properties of NiTi and provide a fusion nail that is resistant to loss of compression or loosening. Specifically, the pseudoelastic IM nail contains an internal NiTi compression element that applies sustained compression during the course of fusion, analogous to external fixators. © 2011 Expert Reviews Ltd

  6. Eyelid Dermatitis Caused by Allergic Contact to Acrylates in Artificial Nails.

    PubMed

    Moreira, Jorge; Gonçalves, Rita; Coelho, Pedro; Maio, Tiago

    2017-03-13

    Over the past few years, there has been an increase in cases of allergic contact dermatitis caused by acrylates, because of the growing popularity of artificial nails. Pathological reactions to artificial nails typically occur on or around the nail area. Eyelid contact dermatitis due to artificial nails is rarely seen, especially in a nonoccupational setting. The authors report the case of a 45-year-old female accountant who developed eyelid dermatitis due to artificial nails.

  7. Incidence and epidemiology of tibial shaft fractures.

    PubMed

    Larsen, Peter; Elsoe, Rasmus; Hansen, Sandra Hope; Graven-Nielsen, Thomas; Laessoe, Uffe; Rasmussen, Sten

    2015-04-01

    The literature lacks recent population-based epidemiology studies of the incidence, trauma mechanism and fracture classification of tibial shaft fractures. The purpose of this study was to provide up-to-date information on the incidence of tibial shaft fractures in a large and complete population and report the distribution of fracture classification, trauma mechanism and patient baseline demographics. Retrospective reviews of clinical and radiological records. A total of 196 patients were treated for 198 tibial shaft fractures in the years 2009 and 2010. The mean age at time of fracture was 38.5 (21.2SD) years. The incidence of tibial shaft fracture was 16.9/100,000/year. Males have the highest incidence of 21.5/100,000/year and present with the highest frequency between the age of 10 and 20, whereas women have a frequency of 12.3/100,000/year and have the highest frequency between the age of 30 and 40. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. The majority of tibial shaft fractures occur during walking, indoor activity and sports. The distribution among genders shows that males present a higher frequency of fractures while participating in sports activities and walking. Women present the highest frequency of fractures while walking and during indoor activities. This study shows an incidence of 16.9/100,000/year for tibial shaft fractures. AO-type 42-A1 was the most common fracture type, representing 34% of all tibial shaft fractures. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Augmentation plating in management of failed femoral nailing.

    PubMed

    Verma, Rahul; Sharma, Pulak; Gaur, Sanjiv

    2017-08-01

    Non-union following interlocking nailing is a troubling complication in treatment of shaft femur fractures. There is no clear consensus on the treatment of this problem. This research was undertaken to study the role of augmentation plating combined with exchange nailing in such cases. A prospective clinical study was undertaken from January 2010 to December 2015. Patients with aseptic femoral shaft non-union, with or without implant failure following intramedullary nailing were included in the study. Augmentation plating combined with Exchange Nailing with a 4.5mm LCP was done. Fifteen patients (nine male and six female) with an average age of 43.7 years (range 18-67 years) were treated. Average timing from the first surgery was 7.3 months. Complete clinical and radiological union was achieved in all cases in a mean duration of 5.2 months. Average duration of follow up was 12.6 months. All the patients retained the preoperative hip and knee range of motion till the last follow up. Augmentation plating combined with exchange nailing in non-unions following intramedullary nailing of femur shaft fractures is a reasonably good and effective procedure with a very high success rate. © 2017 Elsevier Ltd. All rights reserved.

  9. Eyelid Dermatitis Caused by Allergic Contact to Acrylates in Artificial Nails

    PubMed Central

    Moreira, Jorge; Gonçalves, Rita; Coelho, Pedro; Maio, Tiago

    2017-01-01

    Over the past few years, there has been an increase in cases of allergic contact dermatitis caused by acrylates, because of the growing popularity of artificial nails. Pathological reactions to artificial nails typically occur on or around the nail area. Eyelid contact dermatitis due to artificial nails is rarely seen, especially in a nonoccupational setting. The authors report the case of a 45-year-old female accountant who developed eyelid dermatitis due to artificial nails. PMID:28603598

  10. Biomechanical evaluation of primary stiffness of tibiotalocalcaneal fusion with intramedullary nails.

    PubMed

    Mückley, Thomas; Eichorn, Stephan; Hoffmeier, Konrad; von Oldenburg, Geert; Speitling, Andreas; Hoffmann, Gunther O; Bühren, Volker

    2007-02-01

    Intramedullary implants are being used with increasing frequency for tibiotalocalcaneal fusion (TTCF). Clinically, the question arises whether intramedullary (IM) nails should have a compression mode to enhance biomechanical stiffness and fusion-site compression. This biomechanical study compared the primary stability of TTCF constructs using compressed and uncompressed retrograde IM nails and a screw technique in a bone model. For each technique, three composite bone models were used. The implants were a Biomet nail (static locking mode and compressed mode), a T2 femoral nail (compressed mode); a prototype IM nail 1 (PT1, compressed mode), a prototype IM nail 2 (PT2, dynamic locking mode and compressed mode), and a three-screw construct. The compressed contact surface of each construct was measured with pressure-sensitive film and expressed as percent of the available fusion-site area. Stiffness was tested in dorsiflexion and plantarflexion (D/P), varus and valgus (V/V), and internal rotation and external rotation (I/E) (20 load cycles per loading mode). Mean contact surfaces were 84.0 +/- 6.0% for the Biomet nail, 84.0 +/- 13.0% for the T2 nail, 70.0 +/- 7.2% for the PTI nail, and 83.5 +/- 5.5% for the compressed PT2 nail. The greatest primary stiffness in D/P was obtained with the compressed PT2, followed by the compressed Biomet nail. The dynamically locked PT2 produced the least primary stiffness. In V/V, PT1 had the (significantly) greatest primary stiffness, followed by the compressed PT2. The statically locked Biomet nail and the dynamically locked PT2 had the least primary stiffness in V/V. In I/E, the compressed PT2 had the greatest primary stiffness, followed by the PT1 and the T2 nails, which did not differ significantly from each other. The dynamically locked PT2 produced the least primary stiffness. The screw construct's contact surface and stiffness were intermediate. The IM nails with compression used for TTCF produced good contact surfaces and

  11. Impact of a Healthy Nails Program on Nail-Biting in Turkish Schoolchildren: A Controlled Pretest-Posttest Study

    ERIC Educational Resources Information Center

    Ergun, Ayse; Toprak, Rumeysa; Sisman, Fatma Nevin

    2013-01-01

    This study was conducted to examine the effect of a healthy nails program on nail-biting in Turkish schoolchildren. This quasi-experimental study was of pretest-posttest control group design. A total of 50 students of a primary school formed the intervention group, while 53 students from the same school formed the control group. Data were…

  12. Increased revision rate with posterior tibial tunnel placement after using the 70-degree tibial guide in ACL reconstruction.

    PubMed

    Inderhaug, Eivind; Raknes, Sveinung; Østvold, Thomas; Solheim, Eirik; Strand, Torbjørn

    2017-01-01

    To map knee morphology radiographically in a population with a torn ACL and to investigate whether anatomic factors could be related to outcomes after ACL reconstruction at mid- to long-term follow-up. Further, we wanted to assess tibial tunnel placement after using the 70-degree "anti-impingement" tibial tunnel guide and investigate any relation between tunnel placement and revision surgery. Patients undergoing ACL reconstruction involving the 70-degree tibial guide from 2003 to 2008 were included. Two independent investigators analysed pre- and post-operative radiographs. Demographic data and information on revision surgery were collected from an internal database. Anatomic factors and post-operative tibial tunnel placements were investigated as predictors of revision. Three-hundred and seventy-seven patients were included in the study. A large anatomic variation with significant differences between men and women was seen. None of the anatomic factors could be related to a significant increase in revision rate. Patients with a posterior tibial tunnel placement, defined as 50 % or more posterior on the Amis and Jakob line, did, however, have a higher risk of revision surgery compared to patients with an anterior tunnel placement (P = 0.03). Use of the 70-degree tibial guide did result in a high incidence (47 %) of posterior tibial tunnel placements associated with an increased rate of revision surgery. The current study was, however, not able to identify any anatomic variation that could be related to a higher risk of revision surgery. Avoiding graft impingement from the femoral roof in anterior tibial tunnel placements is important, but the insight that overly posterior tunnel placement can lead to inferior outcome should also be kept in mind when performing ACL surgery. IV.

  13. Fractures of the Tibial Plateau Involve Similar Energies as the Tibial Pilon but Greater Articular Surface Involvement

    PubMed Central

    Dibbern, Kevin; Kempton, Laurence B.; Higgins, Thomas F.; Morshed, Saam; McKinley, Todd O.; Marsh, J. Lawrence; Anderson, Donald D.

    2016-01-01

    Patients with tibial pilon fractures have a higher incidence of post-traumatic osteoarthritis than those with fractures of the tibial plateau. This may indicate that pilon fractures present a greater mechanical insult to the joint than do plateau fractures. We tested the hypothesis that fracture energy and articular fracture edge length, two independent indicators of severity, are higher in pilon than plateau fractures. We also evaluated if clinical fracture classification systems accurately reflect severity. Seventy-five tibial plateau fractures and fifty-two tibial pilon fractures from a multi-institutional study were selected to span the spectrum of severity. Fracture severity measures were calculated using objective CT-based image analysis methods. The ranges of fracture energies measured for tibial plateau and pilon fractures were 3.2 to 33.2 Joules (J) and 3.6 to 32.2 J, respectively, and articular fracture edge lengths were 68.0 to 493.0 mm and 56.1 to 288.6 mm, respectively. There were no differences in the fracture energies between the two fracture types, but plateau fractures had greater articular fracture edge lengths (p<0.001). The clinical fracture classifications generally reflected severity, but there was substantial overlap of fracture severity measures between different classes. Clinical Significance Similar fracture energies with different degrees of articular surface involvement suggest a possible explanation for dissimilar rates of post-traumatic osteoarthritis for fractures of the tibial plateau compared to the tibial pilon. The substantial overlap of severity measures between different fracture classes may well have confounded prior clinical studies relying on fracture classification as a surrogate for severity. PMID:27381653

  14. Trifurcation of the tibial nerve within the tarsal tunnel.

    PubMed

    Develi, Sedat

    2018-05-01

    The tibial nerve is the larger terminal branch of the sciatic nerve and it terminates in the tarsal tunnel by giving lateral and medial plantar nerves. We present a rare case of trifurcation of the tibial nerve within the tarsal tunnel. The variant nerve curves laterally after branching from the tibial nerve and courses deep to quadratus plantae muscle. Interestingly, posterior tibial artery was also terminating by giving three branches. These branches were accompanying the terminal branches of the tibial nerve.

  15. Retained portion of latex glove during femoral nailing. Case report.

    PubMed

    Sadat-Ali, M; Marwah, S; al-Habdan, I

    1996-11-01

    A case of retained glove during Kuntscher intramedullary nailing is described. An abscess around the glove could have lead to osteomyelitis. One need to be cautious feeling the top end of the nail while femoral nailing to avoid such a complication.

  16. Nail Care Products

    MedlinePlus

    ... Acrylics") Artificial nails are composed primarily of acrylic polymers and are made by reacting together acrylic monomers, such as ethyl methacrylate monomer, with acrylic polymers, such as polymethylmethacrylate. When the reaction is completed, ...

  17. Pediatric Diaphyseal Femur Fractures: Submuscular Plating Compared With Intramedullary Nailing.

    PubMed

    Sutphen, Sean A; Mendoza, Juan D; Mundy, Andrew C; Yang, Jingzhen G; Beebe, Allan C; Samora, Walter P; Klingele, Kevin E

    2016-11-01

    This study compared the radiographic and clinical outcomes of pediatric diaphyseal femur fractures treated by submuscular plating, flexible retrograde intramedullary nailing, or rigid antegrade intramedullary nailing with a trochanteric entry point in skeletally immature patients who were 8 years and older. A retrospective review was conducted of skeletally immature patients 8 years and older who were treated for femur fracture with submuscular plating, flexible intramedullary nailing, or rigid intramedullary nailing from 2001 to 2014 with a minimum 12-week follow-up. Treatment outcomes were compared for statistical significance, including time to union, malunion, nonunion, heterotopic ossification, avascular necrosis, time to full weight bearing, limb length discrepancy, residual limp, painful hardware, and infection. The study identified 198 femur fractures in 196 patients (mean age, 11.9 years). Each femur fracture was treated with submuscular plating (35), flexible intramedullary nailing (61), or rigid intramedullary nailing (102). Mean follow-up across the cohort was 48 weeks, ranging from 12 to 225 weeks. Flexible nailing was associated with an increased incidence of malunion (P<.0001) and hardware irritation (P=.0204) and longer time to full weight bearing (P=.0018). Rigid nailing was associated with an increased incidence of limp at 12-week followup (P=.0412). Additionally, 23.5% of patients who were treated with rigid nailing had heterotopic ossification. Of all surgical methods, submuscular plating allowed for the most rapid return to full weight bearing (mean, 7 weeks) and offered the fastest healing rate (mean, 6 weeks). Submuscular plating resulted in faster times to union and full weight bearing, with minimal complication rates. Rigid intramedullary nailing with trochanteric entry resulted in a lower incidence of malunion and hardware-related complications; however, these patients had an increased incidence of heterotopic ossification and residual

  18. Geniculate arterial pseudoaneurysm formation following trauma and elective orthopaedic surgery to the knee: 2 case reports and a review of the literature

    PubMed Central

    Shaw, A; Stephen, AB; Lund, JN; Bungay, P; DeNunzio, M

    2009-01-01

    Arterial pseudoaneurysm formation of the genicular vessels following orthopaedic surgery to the knee is an extremely rare occurrence. Here we report the successful management of two cases as a complication of total knee arthroplasty and a tibial interlocking nail, utilising coil embolisation by interventional radiological techniques and negating the need for further surgery. To our knowledge this is one of the few reported cases of pseudoaneurysms of the descending genicular artery secondary to drain placement and only the second following tibial interlocking nail placement. PMID:22470647

  19. Nail polish poisoning

    MedlinePlus

    ... poisoning URL of this page: //medlineplus.gov/ency/article/002722.htm Nail polish poisoning To use the sharing features on this page, please enable JavaScript. This poisoning is from swallowing or breathing in ( ...

  20. Nail Bed Injuries

    MedlinePlus

    ... and Treatment Find a hand surgeon near you. Videos Figures Figure 1: The anatomy of the nail ... or "in." Also, avoid using media types like "video," "article," and "picture." Tip 4: Your results can ...

  1. Functional Analysis and Treatment of Nail Biting

    ERIC Educational Resources Information Center

    Dufrene, Brad A.; Watson, T. Steuart; Kazmerski, Jennifer S.

    2008-01-01

    This study applied functional analysis methodology to nail biting exhibited by a 24-year-old female graduate student. Results from the brief functional analysis indicated variability in nail biting across assessment conditions. Functional analysis data were then used to guide treatment development and implementation. Treatment included a…

  2. Nail Problems (Toenails)

    MedlinePlus

    ... the surface of the nail can be PODIAT PHYSIC filed off, followed by the application of an ... toes ◆ Repeated trauma to the feet from normal activities Problems If you suspect an infection due to ...

  3. Knee arthrodesis using a short locked intramedullary nail. A new technique.

    PubMed

    Cheng, S L; Gross, A E

    1995-01-01

    This article reports on the use of a new intramedullary nail designed specifically for fixation of knee fusions. The nail is a short locked stainless steel nail that is inserted through a single anterior knee incision and uses an outrigger targeting rod to guide the insertion of the locking screws. The successful use of this technique is illustrated in two cases. The advantages of this nail compared with previously reported techniques of fixation for knee fusions are that the short locked nail avoids the second incision required for the insertion of long knee fusion nails, the bulkiness of the double plating technique in the relatively subcutaneous anterior knee area, and the difficulties inherent with the prolonged use of pins for external fixation.

  4. Partial Removal of Nail Matrix in the Treatment of Ingrown Nails: Prospective Randomized Control Study Between Curettage and Electrocauterization.

    PubMed

    Kim, Maru; Song, In-Guk; Kim, Hyung Jin

    2015-06-01

    The aim of this study was to compare the result of electrocauterization and curettage, which can be done with basic instruments. Patients with ingrown nail were randomized to 2 groups. In the first group, nail matrix was removed by curettage, and the second group, nail matrix was removed by electrocautery. A total of 61 patients were enrolled; 32 patients were operated by curettage, and 29 patients were operated by electrocautery. Wound infections, as early complication, were found in 15.6% (5/32) of the curettage group, 10.3% (3/29) of the electrocautery group patients each (P = .710). Nonrecurrence was observed in 93.8% (30/32) and 86.2% (25/29) of the curettage and electrocautery groups, respectively, (lower limit of 1-sided 90% confidence interval = -2.3% > -15% [noninferiority margin]). To remove nail matrix, the curettage is effective as well as the electrocauterization. Further study is required to determine the differences between the procedures. © The Author(s) 2014.

  5. Hand injury with a nail gun: a case report with literature review.

    PubMed

    Boya, Hakan; Uzun, Belkan

    2015-01-01

    The nail gun was introduced in the late 1950s to increase the ease of driving nails, studs, bolts, or staples into various hard surfaces. The nail gun is a potentially dangerous device that is still commonly used in the construction industry. Since its introduction, an increasing number of studies have reported injuries associated with nail guns. Nail gun-related injuries-such as to the head, neck, and chest-can be devastating, and in some cases, even fatal. Extremity injuries, notably in the hand, can cause loss of function, missed work, and long-term health effects. This case report describes a nail-gun injury of the hand along with a discussion of the unique features of and treatment strategies for nail gun injuries.

  6. The use of topical minoxidil to accelerate nail growth: a pilot study.

    PubMed

    Aiempanakit, Kumpol; Geater, Alan; Limtong, Preeyachat; Nicoletti, Kathleen

    2017-07-01

    Linear nail growth rate is affected by various conditions, one of which is the level of blood flow. Our supposition was that topical minoxidil, which has vasodilatory properties, can increase the rate of nail growth. The aim of this study was to determine the impact of topical minoxidil on nail growth. A 5% topical minoxidil solution was applied twice daily to the fingernails of 32 participants. Two groups of 16 participants were randomly chosen. In one group, the applications were made to the right index and left ring fingernails, and, in the other, the left index and right ring fingernails. During each visit (weekly during the first month and every 2 weeks during the second month), the nail length of six fingernails (index, middle, and ring of both hands) was measured using a digital caliper. Beginning in the first week, the mean nail length of the treated nails was greater than that of nails in the untreated group with statistical significance. There were no systemic or cutaneous side effects. During the first month, the mean growth of the treated nails was 4.27 mm/month compared with 3.91 mm/month in the untreated nails (P = 0.003). These findings suggest that a 5% concentration of topical minoxidil can stimulate nail growth with increased growth beginning in the first week of application. The results may have important implications for the treatment of nail disorders; however, a comparable study involving participants with nail disorders is highly recommended. © 2017 The International Society of Dermatology.

  7. Managing Chemotherapy Side Effects: Skin and Nail Changes

    MedlinePlus

    ... ational C ancer I nstitute Managing Chemotherapy Side Effects Skin and Nail Changes “I was glad to ... services national institutes of health Managing Chemotherapy Side Effects: Skin and Nail Changes Protect your skin from ...

  8. Knee arthrodesis with the Wichita fusion nail.

    PubMed

    Domingo, L J; Caballero, M J; Cuenca, J; Herrera, A; Sola, A; Herrero, L

    2004-02-01

    We reviewed 32 patients who all had knee arthrodesis performed after failed knee replacement. The minimum clinical follow-up was 1 year. The arthrodesis was performed by means of the Wichita fusion nail in 11, by external fixation in 15 cases, by plating in three and by intramedullary nailing in three. The mean patient age was 68.6 years. When the Wichita nail was used, fusion was achieved in ten out of 11 cases after a mean period of 4.5 (3-7) months. Of the remaining 21 patients, fusion was only achieved in 11 cases after a mean period of 6.5 (4.5-10) months.

  9. Mycobacteria in nail salon whirlpool footbaths, California.

    PubMed

    Vugia, Duc J; Jang, Yvonne; Zizek, Candi; Ely, Janet; Winthrop, Kevin L; Desmond, Edward

    2005-04-01

    In 2000, an outbreak of Mycobacterium fortuitum furunculosis affected customers using whirlpool footbaths at a nail salon. We swabbed 30 footbaths in 18 nail salons from 5 California counties and found mycobacteria in 29 (97%); M. fortuitum was the most common. Mycobacteria may pose an infectious risk for pedicure customers.

  10. Allergic contact dermatitis from acrylic nails in a flamenco guitarist.

    PubMed

    Alcántara-Nicolás, F A; Pastor-Nieto, M A; Sánchez-Herreros, C; Pérez-Mesonero, R; Melgar-Molero, V; Ballano, A; De-Eusebio, E

    2016-12-01

    Acrylates are molecules that are well known for their strong sensitizing properties. Historically, many beauticians and individuals using store-bought artificial nail products have developed allergic contact dermatitis from acrylates. More recently, the use of acrylic nails among flamenco guitarists to strengthen their nails has become very popular. A 40-year-old non-atopic male patient working as a flamenco guitarist developed dystrophy, onycholysis and paronychia involving the first four nails of his right hand. The lesions were confined to the fingers where acrylic materials were used in order to strengthen his nails to play the guitar. He noticed improvement whenever he stopped using these materials and intense itching and worsening when he began reusing them. Patch tests were performed and positive results obtained with 2-hydroxyethyl methacrylate (2-HEMA), 2-hydroxyethyl acrylate (2-HEA), ethyleneglycol-dimethacrylate (EGDMA) and 2-hydroxypropyl methacrylate (2-HPMA). The patient was diagnosed with occupational allergic contact dermatitis likely caused by acrylic nails. Artificial nails can contain many kinds of acrylic monomers but most cases of contact dermatitis are induced by 2-HEMA, 2-HPMA and EGDMA. This is the first reported case of occupational allergic contact dermatitis from acrylates in artificial nails in a professional flamenco guitar player. Since the practice of self-applying acrylic nail products is becoming very popular within flamenco musicians, we believe that dermatology and occupational medicine specialists should be made aware of the potentially increasing risk of sensitization from acrylates in this setting. © The Author 2016. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  11. Ciclopirox delivery into the human nail plate using novel lipid diffusion enhancers.

    PubMed

    Hafeez, Farhaan; Hui, Xiaoying; Selner, Marc; Rosenthal, Bert; Maibach, Howard

    2014-06-01

    Onychomycosis is a common fungal infection of the nail plate and bed that affects up to 14% of the population and can have a substantial impact on the quality of life of those affected. This study compared the onychopharmacokinetics, nail absorption, nail distribution, and nail penetration of [(14)C]-ciclopirox dissolved in novel lipid diffusion enhancers with that of a commercial ciclopirox nail lacquer using the in vitro finite dose model. The penetration rate of ciclopirox was determined by applying doses of topical formulation twice daily to human nail plates for 11 d. Drug absorption was then measured by monitoring its rate of appearance in each nail layer and in the cotton pad/nail supporting bed. After a multiple day treatment, cumulative concentrations of ciclopirox formulated with lipid enhancers in the deep nail layer and the nail bed were significantly greater than cumulative concentrations of the commercial ciclopirox lacquer (p < 0.001) as well as several orders of magnitude greater than the minimal inhibitory concentration (MIC) deemed necessary to inhibit the growth of the causative dermatophyte species. When formulated with lipid enhancers, the amount of ciclopirox in the ventral/intermediate layer and supporting bed dramatically exceed the inhibitory concentration of ciclopirox for the most common onychomycosis organisms. These results suggest that topical ciclopirox with lipid enhancers has the potential to be an effective topical treatment for onychomycosis, and the lipidic pathway of the nail can be utilized as a means of effective transungual delivery.

  12. Histological analysis of the tibial anterior cruciate ligament insertion.

    PubMed

    Oka, Shinya; Schuhmacher, Peter; Brehmer, Axel; Traut, Ulrike; Kirsch, Joachim; Siebold, Rainer

    2016-03-01

    This study was performed to investigate the morphology of the tibial anterior cruciate ligament (ACL) by histological assessment. The native (undissected) tibial ACL insertion of six fresh-frozen cadaveric knees was cut into four sagittal sections parallel to the long axis of the medial tibial spine. For histological evaluation, the slices were stained with haematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analysed at a magnification of 20×. The anterior tibial ACL insertion was bordered by a bony anterior ridge. The most medial ACL fibres inserted from the medial tibial spine and were adjacent to the articular cartilage of the medial tibial plateau. Parts of the bony insertions of the anterior and posterior horns of the lateral meniscus were in close contact with the lateral part of the tibial ACL insertion. A small fat pad was located just posterior to the functional ACL fibres. The anterior-posterior length of the medial ACL insertion was an average of 10.8 ± 1.1 mm compared with the lateral, which was only 6.2 ± 1.1 mm (p < 0.001). There were no central or posterolateral inserting ACL fibres. The shape of the bony tibial ACL insertion was 'duck-foot-like'. In contrast to previous findings, the functional mid-substance fibres arose from the most posterior part of the 'duck-foot' in a flat and 'c-shaped' way. The most anterior part of the tibial ACL insertion was bordered by a bony anterior ridge and the most medial by the medial tibial spine. No posterolateral fibres nor ACL bundles have been found histologically. This histological investigation may improve our understanding of the tibial ACL insertion and may provide important information for anatomical ACL reconstruction.

  13. Nail involvement in patients with moderate-to-severe alopecia areata treated with oral tofacitinib.

    PubMed

    Lee, Ji Su; Huh, Chang-Hun; Kwon, Ohsang; Yoon, Hyun-Sun; Cho, Soyun; Park, Hyun-Sun

    2018-05-07

    A few anecdotal case reports demonstrated that tofacitinib improved nail changes associated with AA. To investigate nail changes in patients with AA treated with tofacitinib and evaluate the relationship between nail and hair responses to tofacitinib. This is a retrospective study of 33 adult patients with moderate-to-severe AA treated with oral tofacitinib monotherapy for at least 4 months. Fifteen patients had nail involvement and demonstrated more severe hair loss than those without nail involvement (p = .040). However, there was no significant difference in hair regrowth between two groups. Of 15 patients with nail involvement, 11 (73.3%) showed improvement regardless of type of nail change; the first improvement was observed at a median of 5 months (range, 1-11) after administration. Nail improvement was associated with neither initial severity of hair loss nor hair response to tofacitinib. Nail improvement tended to occur later than hair regrowth. Oral tofacitinib monotherapy improves nail involvement associated with AA. Nail involvement is not a poor prognosis factor in hair regrowth with tofacitinib treatment and there is no evident relationship between nail and hair responses.

  14. Mycobacteria in Nail Salon Whirlpool Footbaths, California

    PubMed Central

    Jang, Yvonne; Zizek, Candi; Ely, Janet; Winthrop, Kevin L.; Desmond, Edward

    2005-01-01

    In 2000, an outbreak of Mycobacterium fortuitum furunculosis affected customers using whirlpool footbaths at a nail salon. We swabbed 30 footbaths in 18 nail salons from 5 California counties and found mycobacteria in 29 (97%); M. fortuitum was the most common. Mycobacteria may pose an infectious risk for pedicure customers. PMID:15829204

  15. When all you have is a dermatoscope— start looking at the nails

    PubMed Central

    Haenssle, Holger A.; Blum, Andreas; Hofmann-Wellenhof, Rainer; Kreusch, Juergen; Stolz, Wilhelm; Argenziano, Giuseppe; Zalaudek, Iris; Brehmer, Franziska

    2014-01-01

    Pigmented and non-pigmented nail alterations are a frequent challenge for dermatologists. A profound knowledge of clinical and dermatoscopic features of nail disorders is crucial because a range of differential diagnoses and even potentially life-threatening diseases are possible underlying causes. Nail matrix melanocytes of unaffected individuals are in a dormant state, and, therefore, fingernails and toenails physiologically are non-pigmented. The formation of continuous, longitudinal pigmented streaks (longitudinal melanonychia) may either be caused by a benign activation of matrix melanocytes (e.g., as a result of trauma, inflammation, or adverse drug reactions) or by a true melanocytic proliferation (e.g., in a nevus or melanoma). In general, non-continuous nail alterations, affecting only limited parts of the nail apparatus, are most frequently of non-melanocytic origin. Important and common differential diagnoses in these cases are subungual hemorrhage or onychomycosis. In addition, foreign bodies, bacterial infections, traumatic injuries, or artificial discolorations of the nail unit may less frequently cause non-continuous nail alterations. Many systemic diseases that may also show involvement of the nails (e.g., psoriasis, atopic dermatitis, lichen planus, alopecia areata) tend to induce alterations in numerous if not all nails of the hands and feet. A similar extensive and generalized alteration of nails has been reported after treatment with a number of systemic drugs, especially antibiotics and cytostatics. Benign or malignant neoplasms that may also affect the nail unit include glomus tumor, Bowen’s disease, squamous cell carcinoma, and rare collision tumors. This review aims to assist clinicians in correctly evaluating and diagnosing nail disorders with the help of dermatoscopy. PMID:25396079

  16. [Scabies of the nail unit in an infant].

    PubMed

    Finon, A; Desoubeaux, G; Nadal, M; Georgescou, G; Baran, R; Maruani, A

    2017-05-01

    There are no guidelines regarding the management of scabies in infants and recurrence is common at this age. We report the case of an infant with subungual hyperkeratosis and ungual lesions subsequent to classic scabies. A 7-month-girl, treated 6 weeks earlier with esdepallethrin for scabies, consulted for acquired lesions on 3 toe nails. These nails were thickened and displayed subungual hyperkeratosis. Physical examination of the skin, the finger nails and mucous membranes was otherwise normal. Fungal analyses were negative, but direct microscopic examination revealed numerous larvae of Sarcoptes scabiei as well as ovular debris. The child was treated with urea 40% to obtain chemical avulsion of the nails, and with topical esdepallethrin and a quarter tablet of ivermectin orally; there was no follow-up of the child. Ungual scabies has already been reported in crusted scabies and very rarely in classic scabies. Subungual and ungual locations of S. scabiei may constitute a source of reinfestation with scabies in infants. Treatment is not well defined and currently involves chemical avulsion of the nails and the application of topical antiscabies treatment. Copyright © 2016. Published by Elsevier Masson SAS.

  17. Intramedullary fixation of forearm fractures with new locked nail.

    PubMed

    Bansal, Himanshu

    2011-09-01

    Lack of availability of interlocked nails made plate osteosynthesis the first choice of treatment of forearm fractures inspite of more surgical exposure, periosteal stripping and big skin incision subsequent scar along with higher risk of refracture on implant removal. We hereby report the first 12 cases with 19 forearm bone fractures internally fixed by indegenous interlocked nail. Existing square nails were modified to have a broad proximal end of 5.5 mm with a hole for locking screw of 2.5 mm. The nail has a distal hole of 1/1.2/1.5 mm in 2.5/3/3.5 mm diameter nail, respectively. A new method of distal locking with a clip made of k wire is designed. The clip after insertion into the bone and hole in nail and opposite cortex snuggly fits the bone providing a secure locking system. Twelve skeletally mature patients, mean age 32 years (range 24-45 years) with 19 diaphyseal fractures of the forearm were treated with this indigenously made new nail. The patient were evaluated for fracture union, functional recovery and complications. The functional outcome was assessed by disabilities of arm, shoulder and hand questionnaire (DASH score). Time to radiographic union ranged between 12 and 28 weeks, with a 100% union rate. Complications were minimal, with mild infection in open fracture (n=1) and delayed union (n=1) in patient with comminuted fracture of the ulna only. The clinical results were excellent. The DASH score ranged between 0 and 36 points. This new interlocking nail may be considered as an alternative to plate osteosynthesis for fractures of the forearm in adults. The advantages are benefit of closed reduction, smaller residual scar, reduced cost and early union with allowance of immediate movements.

  18. Next generation distal locking for intramedullary nails using an electromagnetic X-ray-radiation-free real-time navigation system.

    PubMed

    Hoffmann, Michael; Schröder, Malte; Lehmann, Wolfgang; Kammal, Michael; Rueger, Johannes Maria; Herrman Ruecker, Andreas

    2012-07-01

    Distal locking marks one challenging step during intramedullary nailing that can lead to an increased irradiation and prolonged operation times. The aim of this study was to evaluate the reliability and efficacy of an X-ray-radiation-free real-time navigation system for distal locking procedures. A prospective randomized cadaver study with 50 standard free-hand fluoroscopic-guided and 50 electromagnetic-guided distal locking procedures was performed. All procedures were timed using a stopwatch. Intraoperative fluoroscopy exposure time and absorbed radiation dose (mGy) readings were documented. All tibial nails were locked with two mediolateral and one anteroposterior screw. Successful distal locking was accomplished once correct placement of all three screws was confirmed. Successful distal locking was achieved in 98 cases. No complications were encountered using the electromagnetic navigation system. Eight complications arose during free-hand fluoroscopic distal locking. Undetected secondary drill slippage on the ipsilateral cortex accounted for most problems followed by undetected intradrilling misdirection causing a fissural fracture of the contralateral cortex while screw insertion in one case. Compared with the free-hand fluoroscopic technique, electromagnetically navigated distal locking provides a median time benefit of 244 seconds without using ionizing radiation. Compared with the standard free-hand fluoroscopic technique, the electromagnetic guidance system used in this study showed high reliability and was associated with less complications, took significantly less time, and used no radiation exposure for distal locking procedures. Therapeutic study, level II.

  19. Tibiotalocalcaneal Arthrodesis Using a Nitinol Intramedullary Hindfoot Nail.

    PubMed

    Hsu, Andrew R; Ellington, J Kent; Adams, Samuel B

    2015-10-01

    Tibiotalocalcaneal (TTC) arthrodesis using an intramedullary hindfoot nail is a common procedure for deformity correction and the treatment of combined tibiotalar and subtalar end-stage arthritis. Nonunion at one or both fusion sites is a difficult complication that can result in reoperation, significant morbidity, and below-knee amputation. There is currently a need for sustained compression across fusion sites using a TTC hindfoot nail with good mechanical stability. The DynaNail TTC Fusion System (MedShape, Inc, Atlanta, GA) uses an internal nitinol compression element to apply sustained compression across the tibiotalar and subtalar joints after surgery. In preliminary clinical cases, we have found that the nail is safe, reliable, and has promising clinical and radiographic results in settings of hindfoot arthritis, complex deformity, Charcot arthropathy, and talar avascular necrosis. Expert opinion, Level V. © 2015 The Author(s).

  20. Do modern total knee replacements improve tibial coverage?

    PubMed

    Meier, Malin; Webb, Jonathan; Collins, Jamie E; Beckmann, Johannes; Fitz, Wolfgang

    2018-01-25

    The purpose of the present study is to compare newer designs of various symmetric and asymmetric tibial components and measure tibial bone coverage using the rotational safe zone defined by two commonly utilized anatomic rotational landmarks. Computed tomography scans (CT scans) of one hundred consecutive patients scheduled for total knee arthroplasty were obtained pre-operatively. A virtual proximal tibial cut was performed and two commonly used rotational axes were added for each image: the medio-lateral axis (ML-axis) and the medial 1/3 tibial tubercle axis (med-1/3-axis). Different symmetric and asymmetric implant designs were then superimposed in various rotational positions for best cancellous and cortical coverage. The images were imported to a public domain imaging software, and cancellous and cortical bone coverage was computed for each image, with each implant design in various rotational positions. One single implant type could not be identified that provided the best cortical and cancellous coverage of the tibia, irrespective of using the med-1/3-axis or the ML-axis for rotational alignment. However, it could be confirmed that the best bone coverage was dependent on the selected rotational landmark. Furthermore, improved bone coverage was observed when tibial implant positions were optimized between the two rotational axes. Tibial coverage is similar for symmetric and asymmetric designs, but depends on the rotational landmark for which the implant is designed. The surgeon has the option to improve tibial coverage by optimizing placement between the two anatomic rotational alignment landmarks, the medial 1/3 and the ML-axis. Surgeons should be careful assessing intraoperative rotational tibial placement using the described anatomic rotational landmarks to optimize tibial bony coverage without compromising patella tracking. III.

  1. Preserving the PCL during the tibial cut in total knee arthroplasty.

    PubMed

    Cinotti, G; Sessa, P; Amato, M; Ripani, F R; Giannicola, G

    2017-08-01

    Previous studies have shown that the PCL insertion may be damaged during the tibial cut performed in total knee arthroplasty. We investigated the maximum thickness of a tibial cut that preserves the PCL insertion and to what extent the posterior slope of the tibial cut and that of the patient's tibial plateaus affect the outcome. MR images of 83 knees were analysed. The maximum thickness of a tibial cut that preserves the PCL using a posterior slope of 0°, 3°, 5° and parallel to the patient's slope of the tibial plateau, was evaluated. Correlations between the results and the degrees of the posterior slope of the patient's tibial plateaus were also investigated. The maximum thickness of a tibial cut that preserves the entire PCL insertion was, on average, 5.5, 4.7, 4.2 and 3.1 mm when a posterior slope of 0°, 3°, 5° and parallel to the patients' tibial plateaus was used, respectively. When the 25th percentile was considered, the maximum thickness of a tibial cut that preserved the PCL was 4 and 3 mm with a tibial cut of 0° and 5° of posterior slope, respectively. The maximum thickness of a tibial cut that preserved the PCL was significantly greater in patients with a sagittal slope of the tibial plateaus more than 8° than in those with a sagittal slope less than 8°. In cruciate retaining implants, the PCL insertion may be spared in the majority of patients by performing a tibial cut of 4 mm, or even less when a posterior slope of 3°-5° is used. The clinical relevance of our study is that the execution of a conservative tibial cut, followed by a second tibial resection to achieve the thickness required for the tibial component to be implanted, may be an alternative technique to spare the PCL in CR TKA. II.

  2. Coexistence of nail lichen planus and lichen planus pigmentosus.

    PubMed

    Lemes, Luciana Rodino; Verde, Renata Brandão Villa; Durães, Sandra Maria Barbosa; Araripe, Adolpho de Alencar; Pantaleão, Luciana

    2016-01-01

    We describe a fifty-six-year old, Afro-descendent female patient showing dystrophy of her twenty nails and hyperchromic, asymptomatic macule on her face. Histopathological examination of the macule showed vacuolization of the basal layer, melanophages in the superficial dermis and lymphoplasmocytic inflammatory infiltrate. Nail biopsy revealed orthokeratotic hyperkeratosis and lichenoid inflammatory infiltrate. Lichen planus pigmentosus is an uncommon variety of lichen planus. It is characterized by typical hyperpigmented macules on the face and neck. Nail changes might be present in 10% of lichen planus cases, but no associations with lichen planus pigmentosus have been described. We report a case of lichen planus in twenty nails associated with lichen planus pigmentosus on the patient's face.

  3. Bypass grafting to the anterior tibial artery.

    PubMed

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  4. Post-traumatic cerebral fat embolism prior to operative repair of femoral and tibial fractures.

    PubMed

    Kim, Kyung-Cheon; Hwang, Deuk-Soo; Shin, Hyun-Dae

    2008-02-01

    Rare cases of primary cerebral fat embolism as a postoperative complication have been reported. In addition, cerebral fat embolism occurring before operative repair without shunt lesion are more rarely reported. We report a patient with a posttraumatic cerebral fat embolism resulting in severe neurologic dysfunction without right to left shunt. A 25-year-old man was brought to the hospital immediately after a traffic accident. He sustained a right segmental femoral shaft fracture and a left tibial shaft fracture. The patient was alert with no neurological deficits. Approximately 13 hours after injury, the patient developed acute mental status deterioration and dyspnea. Magnetic resonance imaging of the brain revealed extensive multifocal infarction owing to embolic showering throughout nearly the entire brain parenchyma. Computed tomography with intravenous contrast revealed no evidence of embolism in the lung, abdomen, and pelvis. Transthoracic and transesophageal echocardiogram revealed no circulating embolic particles or intracardiac shunt. The patient underwent closed reduction and internal fixation with a reamed intramedullary nail in the tibia and underwent open reduction and internal fixation with a reamed nail in the femur at 5 days after injury. We performed decompression of a hematoma containing a large number of lipid droplets via a small incision in the femur shaft fracture, established suction drainage of the tibia medullar cavity, and applied a tourniquet to the thigh in the tibia shaft fracture. Supportive medical treatment included endotracheal ventilatory support and tracheostomy. The patient was discharged from the hospital 50 days after admission. On follow-up 2 months later, he had returned to activities of daily living, however a speech disturbance remained.

  5. Size and Charge Dependence of Ion Transport in Human Nail Plate

    PubMed Central

    Baswan, Sudhir M.; Li, S. Kevin; LaCount, Terri D.; Kasting, Gerald B.

    2016-01-01

    The electrical properties of human nail plate are poorly characterized, yet are a key determinate of the potential to treat nail diseases such as onychomycosis using iontophoresis. In order to address this deficiency, molar conductivities of 17 electrolytes comprising 12 ionic species were determined in hydrated human nail plate in vitro. Cation transport numbers across the nail for 11 of these electrolytes were determined by the electromotive force method. Effective ionic mobilities and diffusivities at infinite dilution for all ionic species were determined by regression analysis. The ratios of diffusivities in nail to those in solution were found to correlate inversely with the hydrodynamic radii of the ions according to a power law relationship having an exponent of −1.75 ± 0.27, a substantially steeper size dependence than observed for similar experiments in skin. Effective diffusivities of cations in nail were three-fold higher than those of comparably sized anions. These results reflect the strong size and charge selectivity of the nail plate for ionic conduction and diffusion. The analysis implies that efficient transungual iontophoretic delivery of ionized drugs having radii upwards of 5 Å (approximately MW ≥ 340 Da) will require chemical or mechanical alteration of the nail plate. PMID:26886342

  6. Size and Charge Dependence of Ion Transport in Human Nail Plate.

    PubMed

    Baswan, Sudhir M; Li, S Kevin; LaCount, Terri D; Kasting, Gerald B

    2016-03-01

    The electrical properties of human nail plate are poorly characterized yet are a key determinate of the potential to treat nail diseases, such as onychomycosis, using iontophoresis. To address this deficiency, molar conductivities of 17 electrolytes comprising 12 ionic species were determined in hydrated human nail plate in vitro. Cation transport numbers across the nail for 11 of these electrolytes were determined by the electromotive force method. Effective ionic mobilities and diffusivities at infinite dilution for all ionic species were determined by regression analysis. The ratios of diffusivities in nail to those in solution were found to correlate inversely with the hydrodynamic radii of the ions according to a power law relationship having an exponent of -1.75 ± 0.27, a substantially steeper size dependence than observed for similar experiments in skin. Effective diffusivities of cations in nail were 3-fold higher than those of comparably sized anions. These results reflect the strong size and charge selectivity of the nail plate for ionic conduction and diffusion. The analysis implies that efficient transungual iontophoretic delivery of ionized drugs having radii upward of 5 Å (molecular weight, ca. ≥ 340 Da) will require chemical or mechanical alteration of the nail plate. Copyright © 2016 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  7. Use of flexible facing for soil nail walls.

    DOT National Transportation Integrated Search

    2011-11-01

    Soil nail walls are a widely used technology for retaining vertical and nearly vertical cuts in soil. A : significant portion of the cost of soil nail wall construction is related to the construction of a reinforced : concrete face. The potential for...

  8. Green Nail Syndrome

    MedlinePlus

    ... if continued for one to four months. Alternatively, chlorine bleach, diluted 1:4 with water, is effective in suppressing growth of P. aeruginosa when applied topically to affected nails. Vinegar (acetic acid) has been reported to be useful in this ...

  9. Physeal growth arrest after tibial lengthening in achondroplasia

    PubMed Central

    2012-01-01

    Background and purpose Bilateral tibial lengthening has become one of the standard treatments for upper segment-lower segment disproportion and to improve quality of life in achondroplasia. We determined the effect of tibial lengthening on the tibial physis and compared tibial growth that occurred at the physis with that in non-operated patients with acondroplasia. Methods We performed a retrospective analysis of serial radiographs until skeletal maturity in 23 achondroplasia patients who underwent bilateral tibial lengthening before skeletal maturity (lengthening group L) and 12 achondroplasia patients of similar height and age who did not undergo tibial lengthening (control group C). The mean amount of lengthening of tibia in group L was 9.2 cm (lengthening percentage: 60%) and the mean age at the time of lengthening was 8.2 years. The mean duration of follow-up was 9.8 years. Results Skeletal maturity (fusion of physis) occurred at 15.2 years in group L and at 16.0 years in group C. The actual length of tibia (without distraction) at skeletal maturity was 238 mm in group L and 277 mm in group C (p = 0.03). The mean growth rates showed a decrease in group L relative to group C from about 2 years after surgery. Physeal closure was most pronounced on the anterolateral proximal tibial physis, with relative preservation of the distal physis. Interpretation Our findings indicate that physeal growth rate can be disturbed after tibial lengthening in achondroplasia, and a close watch should be kept for such an occurrence—especially when lengthening of more than 50% is attempted. PMID:22489887

  10. Withdrawal Strength and Bending Yield Strength of Stainless Steel Nails

    Treesearch

    Douglas R. Rammer; Samuel L. Zelinka

    2015-01-01

    It has been well established that stainless steel nails have superior corrosion performance compared to carbon steel or galvanized nails in treated wood; however, their mechanical fastening behavior is unknown. In this paper, the performance of stainless steel nails is examined with respect to two important properties used in wood connection design: withdrawal strength...

  11. TOXIC TRACE METALS IN MAMMALIAN HAIR AND NAILS

    EPA Science Inventory

    Data have been compiled from the available world literature on the accumulation and bioconcentration of selected toxic trace metals in human hair and nails and other mammalian hair, fur, nails, claws, and hoofs. The toxic trace metals and metalloids include antimony, arsenic, bor...

  12. (Meth)Acrylate Occupational Contact Dermatitis in Nail Salon Workers: A Case Series.

    PubMed

    DeKoven, Samuel; DeKoven, Joel; Holness, D Linn

    Recently, many cases of acrylate-associated allergic contact dermatitis have appeared among nail salon workers. Common acrylate-containing products in nail salons include traditional nail polish, ultraviolet-cured shellac nail polish, ultraviolet-cured gel nails, and press-on acrylic nails. Nail salon technicians seen in the occupational medicine clinic in 2015 and 2016 were identified, and their patch test results and clinical features were summarized. Patch testing was done with the Chemotechnique (Meth)Acrylate nail series, and either the North American Standard series or the North American Contact Dermatitis Group screening series. Six patients were identified, all women, ages 38 to 58. Common presentations included erythematous dermatitis of the dorsa of the hands, palms, and forearms and fissures on the fingertips. Less common sites of eruptions included the periorbital region, cheeks, posterior ears, neck, sacral area, lateral thighs, and dorsa of the feet. All patients reacted to hydroxyethyl methacrylate, and 5 patients reacted to ethyl acrylate. Each patient also reacted to (meth)acrylates that are not found on either standard series, including ethyleneglycol dimethacrylate, 2-hydroxypropyl methacrylate, and 2-hydroxyethyl acrylate. The authors report 6 cases of allergic contact dermatitis to acrylates in nail technicians seen over the past year, representing a new trend in their clinic. These cases are reflective of a growing trend of nail technicians with allergic contact dermatitis associated with occupational (meth)acrylate exposure. Efforts to improve prevention are needed.

  13. Research on the reasonable pile spacing of micro pile composite soil nailing

    NASA Astrophysics Data System (ADS)

    Liu, Jun yan; Liu, Yan; Song, Xiang hua

    2017-08-01

    Through the numerical simulation software FLAC3D, study on the synergetic effect of micro pile composite soil nailing will be studied. By adjusting the micro pile spacing and analysing the displacement field and stress field of soil, we can find that supporting effect of the soil nail hasn’t work yet when the micro pile spacing is 2D. The soil arching between piles has been formed in the pile spacing 4D ∼ 6D. The composite effect of micro pile and soil nailing will be the best and the soil arch behind piles will be firstly formed in 6D, the horizontal saddle soil arch will be formed between the nails. The nail head coincidence pressure area and micro pile pressure area are overlapping to maintain stability in the soil between piles. When the micro pile spacing is 9D, the arch behind piles will be failure, the soil flows around, but the saddle arch between the nails into circular arch, the supporting effect of the soil nailing is enhanced. When the micro pile spacing is 12D, the arch of the nails becomes smaller, sliding surface appears primitively. Based on the conclusions above, it is suggested that the micro pile spacing between 2D ∼ 6D is suitable for the micro pile and soil nailing composite support. The conclusion can provide theoretical basis for the design and construction of micro pile composite soil nailing.

  14. Anterior Cruciate Ligament Reconstruction with Tibial Attachment Preserving Hamstring Graft without Implant on Tibial Side

    PubMed Central

    Sinha, Skand; Naik, Ananta Kumar; Maheshwari, Mridul; Sandanshiv, Sumedh; Meena, Durgashankar; Arya, Rajendra K

    2018-01-01

    Background: Tibial attachment preserving hamstring graft could prevent potential problems of free graft in anterior cruciate ligament (ACL) reconstruction such as pull out before graft-tunnel healing or rupture before ligamentization. Different implants have been reportedly used for tibial side fixation with this technique. We investigated short-term outcome of ACL reconstruction (ACLR) with tibial attachment sparing hamstring graft without implant on the tibial side by outside in technique. Materials and Methods: Seventy nine consecutive cases of ACL tear having age of 25.7 ± 6.8 years were included after Institutional Board Approval. All subjects were male. The mean time interval from injury to surgery was of 7.5 ± 6.4 months. Hamstring tendons were harvested with open tendon stripper leaving the tibial insertion intact. The free ends of the tendons were whip stitched, quadrupled, and whip stitched again over the insertion site of hamstring with fiber wire (Arthrex). Single bundle ACLR was done by outside in technique and the femoral tunnel was created with cannulated reamer. The graft was pulled up to the external aperture of femoral tunnel and fixed with interference screw (Arthrex). The scoring was done by Lysholm, Tegner, and KT 1000 by independent observers. All cases were followed up for 2 years. Results: The mean length of quadrupled graft attached to tibia was 127.65 ± 7.5 mm, and the mean width was 7.52 ± 0.78 mm. The mean preoperative Lysholm score of 47.15 ± 9.6, improved to 96.8 ± 2.4 at 1 year. All cases except two returned to the previous level of activity after ACLR. There was no significant difference statistically between preinjury (5.89 ± 0.68) and postoperative (5.87 ± 0.67) Tegner score. The anterior tibial translation (ATT) (KT 1000) improved from 11.44 ± 1.93 mm to 3.59 ± 0.89 mm. The ATT of operated knee returned to nearly the similar value as of the opposite knee (3.47 ± 1.16 mm). The Pivot shift test was negative in all cases

  15. Sensory factors affecting female consumers' acceptability of nail polish.

    PubMed

    Sun, C; Koppel, K; Adhikari, K

    2015-12-01

    The objectives of this study were to determine what sensory factors impact consumers' acceptability of nail polishes, to explore how these sensory factors impact consumers' acceptability of nail polishes, to investigate whether there are any consumer segments according to their overall acceptability on different nail polishes and to scrutinize how the consumer segments are related to the sensory factors. Ninety-eight females participated in a nail polish consumer study at Kansas State University. Eight commercial products belonging to four categories - regular (REG), gel (GEL), flake (FLK) and water-based (WAT) - were evaluated. Each nail polish sample was evaluated twice by each participant in two different tasks - a task devoted to applying and evaluating the product and a task devoted to observing the appearance and evaluating the product. Pearson's correlation analysis, analysis of variance (ANOVA), external preference mapping, cluster analysis and internal preference mapping were applied for data analysis. Participants' scores of overall liking of the nail polishes were similar in the application task and in the observation task. In general, participants liked the REG and GEL product samples more than the FLK and WAT samples. Among all the sensory attributes, appearance attributes were the major factors that affected participants' overall liking. Aroma seemed to be a minor factor to participants' overall liking. Some sensory attributes, such as runny, shininess, opacity, spreadability, smoothness, coverage and wet appearance, were found to drive participants' overall acceptability positively, whereas others such as pinhole, fatty-edges, blister, brushlines, pearl-like, flake-protrusion, glittery and initial-drag impacted participants' overall acceptability negatively. Four clusters of participants were identified according to their overall liking scores from both the application task and the observation task. Participants' acceptability, based on different

  16. Skin or nail culture

    MedlinePlus

    Mucosal culture; Culture - skin; Culture - mucosal; Nail culture; Culture - fingernail; Fingernail culture ... There, it is placed in a special dish (culture). It is then watched to see if bacteria, ...

  17. Comparative study of nail sampling techniques in onychomycosis.

    PubMed

    Shemer, Avner; Davidovici, Batya; Grunwald, Marcelo H; Trau, Henri; Amichai, Boaz

    2009-07-01

    Onychomycosis is a common problem. Obtaining accurate laboratory test results before treatment is important in clinical practice. The purpose of this study was to compare results of curettage and drilling techniques of nail sampling in the diagnosis of onychomycosis, and to establish the best technique and location of sampling. We evaluated 60 patients suffering from distal and lateral subungual onychomycosis and lateral subungual onychomycosis using curettage and vertical and horizontal drilling sampling techniques from three different sites of the infected nail. KOH examination and fungal culture were used for detection and identification of fungal infection. At each sample site, the horizontal drilling technique has a better culture sensitivity than curettage. Trichophyton rubrum was by far the most common pathogen detected by both techniques from all sampling sites. The drilling technique was found to be statistically better than curettage at each site of sampling, furthermore vertical drilling from the proximal part of the affected nail was found to be the best procedure for nail sampling. With each technique we found that the culture sensitivity improved as the location of the sample was more proximal. More types of pathogens were detected in samples taken by both methods from proximal parts of the affected nails.

  18. Application of soil nails to the stability of mine waste slopes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tant, C.R.; Drumm, E.C.; Mauldon, M.

    1996-12-31

    The traditional soil nailed structure incorporates grouted or driven nails, and a wire mesh reinforced shotcrete facing to increase the stability of a slope or wall. This paper describes the construction and monitoring of a full-scale demonstration of nailing to stabilize coal mine spoil. The purpose of the investigation is to evaluate the performance of nailed slopes in mine spoil using methods proven for the stabilization of soil walls and slopes. The site in eastern Tennessee is a 12 meter high slope of dumped fill, composed of weathered shale chips, sandstone, and coal. The slope was formed by {open_quotes}pre-regulatory{close_quotes} contourmore » surface mining operations and served as a work bench during mining. The material varies in size from silt to boulders, and has a small amount of cohesion. Portions of the mine spoil slope have experienced slope instability and erosion which have hampered subsequent reclamation activities. Three different nail spacings and three different nail lengths were used in the design. The 12 meter high structure is instrumented to permit measurement of nail strain, and vertical inclinometer readings and survey measurements will be used for the detection of ground movement. The results of this study will aid in the development of design recommendations and construction guidelines for the application of soil nailing to stabilize mine spoil.« less

  19. Attic Retrofits Using Nail-Base Insulated Panels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mallay, David; Kochkin, Vladimir

    This project developed and demonstrated a roof/attic energy retrofit solution using nail-base insulated panels for existing homes where traditional attic insulation approaches are not effective or feasible. Nail-base insulated panels (retrofit panels) consist of rigid foam insulation laminated to one face of a wood structural panel. The prefabricated panels are installed above the existing roof deck during a reroofing effort.

  20. Biomechanical investigation of titanium elastic nail prebending for treating diaphyseal long bone fractures.

    PubMed

    Chen, Yen-Nien; Lee, Pei-Yuan; Chang, Chih-Wei; Ho, Yi-Hung; Peng, Yao-Te; Chang, Chih-Han; Li, Chun-Ting

    2017-03-01

    This study numerically investigated the deformation of titanium elastic nails prebent at various degrees during implantation into the intramedullary canal of fractured bones and the mechanism by which this prebending influenced the stability of the fractured bone. Three degrees of prebending the implanted portions of the nails were used: equal to, two times, and three times the diameter of the intramedullary canal. Furthermore, a simulated diaphyseal fracture with a 5-mm gap was created in the middle shaft portion of the bone fixed with two elastic nails in a double C-type configuration. End caps were simulated using a constraint equation. To confirm that the simulation process is able to present the mechanical response of the nail inside the intramedullary, an experiment was conducted by using sawbone for validation. The results indicated that increasing the degrees of nail prebending facilitated straightening the nails against the inner aspect of canal after implantation, with increase in stability under torsion. Furthermore, reducing nail prebending caused a larger portion of the nails to move closer to the loading site and center of bone after implantation; the use of end caps prevented the nail tips from collapsing and increased axial stability. End cap use was critical for preventing the nail tips from collapsing and for increasing the stability of the nails prebent at a degree equal to the diameter of the canal with insufficient frictional force between the nail and canal. Therefore, titanium elastic nail prebending in a double C-type configuration with a degree three times the diameter of the canal represents a superior solution for treating transverse fractures without a gap, whereas that with a degree equal to the diameter of the intramedullary canal and combined with end cap use represents an advanced solution for treating comminuted fractures in a diaphyseal long bone fracture.

  1. 77 FR 27080 - Certain Steel Nails From the United Arab Emirates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-08

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 (Final)] Certain Steel Nails From... is materially injured by reason of imports from the United Arab Emirates of certain steel nails... of certain steel nails from the United Arab Emirates were being sold at LTFV within the meaning of...

  2. Management of Nail Bed Injuries Associated with Fingertip Injuries.

    PubMed

    George, Alexander; Alexander, Reena; Manju, C

    2017-01-01

    Management of nail injuries can often be a challenging experience, especially in presence of complex fingertips' injuries that include soft tissue loss and distal phalanx injury. Most studies found in the literature focus on individual injuries and describe methods to tackle those injuries, notwithstanding the fact that the nail, nailbed, distal phalanx, soft tissue and skin of the finger tip form a complex and often more than one element of this complex is injured. This retrospective study therefore focuses on the management of nail bed injuries as a part of the complex finger tip injury and outlines the surgical principles and techniques that were used in their management. Two hundred and forty patients from a tertiary care center in different clinical settings where a wide variety of cases involving the nail bed injuries were included in this study. Patients comprised of 192 (80%) males and 48 (20%) females with the average male age of 37.3 years (range 1-66 years) and average female age of 29 years (range 1-59 years). 210 patients had single finger involment, 30 patients had two finger involvement (total fingers involved- 270). The middle finger was most commonly involved while the index finger was the second most commonest finger involved. In 198 (89.18%) patients local anaesthesia was used while in the rest: regional blocks [ n = 10 (4.5%)] and general anaesthesia [ n = 14 (6.3%)] were used. In this retrospective study, out of the total of two hundred and forty patients, 222 (92.5%) patients underwent surgery, while the rest 18 (7.5%) were treated conservatively. Two hundred and ten patients who underwent surgery had complete healing over the course of treatment and followup, while four patients needed secondary interventional. Eight patients who had surgery were migrant workers were lost to follow up after surgery. Eight patients had postoperative complications that included infection, secondary necrosis, wound breakdown and non healing fractures. Accurate

  3. Nail gun injuries in residential carpentry: lessons from active injury surveillance.

    PubMed

    Lipscomb, H J; Dement, J M; Nolan, J; Patterson, D; Li, L

    2003-03-01

    To describe circumstances surrounding injuries involving nail guns among carpenters, calculate injury rates, identify high risk groups and preventive measures. and setting: Active injury surveillance was used to identify causes of injury among a large cohort of union residential and drywall carpenters. Injured carpenters were interviewed by experienced journeymen; enumeration of workers and hourworked were provided by the union. The combined data allowed definition of a cohort of carpenters, their hours worked, detailed information on the circumstances surrounding injuries, and identification of preventive measures from the perspectives of the injured worker and an experienced investigator. Nail guns were involved in 14% of injuries investigated. Ninety percent of these injuries were the result of the carpenter being struck, most commonly by a nail puncturing a hand or fingers. The injury rate among apprentices was 3.7 per 200 000 hours worked (95% confidence interval (CI) 2.7 to 4.9) compared with a rate of 1.2 among journeymen (95% CI 0.80 to 1.7). While not always the sole contributing factor, a sequential trigger would have likely prevented 65% of the injuries from tools with contact trip triggers. Training, engineering, and policy changes in the workplace and manufacturing arena are all appropriate targets for prevention of these injuries. Use of sequential triggers would likely decrease acute injury rates markedly. Over 70% of injuries among residential carpenters were associated with through nailing tasks (such as nailing studs or blocks, trusses or joists) or toe nailing (angled, corner nailing) as opposed to flat nailing used for sheathing activities; this provides some indication that contact trip tools could be used solely for flat nailing.

  4. Nail gun injuries in residential carpentry: lessons from active injury surveillance

    PubMed Central

    Lipscomb, H; Dement, J; Nolan, J; Patterson, D; Li, L

    2003-01-01

    Objective: To describe circumstances surrounding injuries involving nail guns among carpenters, calculate injury rates, identify high risk groups and preventive measures. Methods and setting: Active injury surveillance was used to identify causes of injury among a large cohort of union residential and drywall carpenters. Injured carpenters were interviewed by experienced journeymen; enumeration of workers and hourworked were provided by the union. The combined data allowed definition of a cohort of carpenters, their hours worked, detailed information on the circumstances surrounding injuries, and identification of preventive measures from the perspectives of the injured worker and an experienced investigator. Results: Nail guns were involved in 14% of injuries investigated. Ninety percent of these injuries were the result of the carpenter being struck, most commonly by a nail puncturing a hand or fingers. The injury rate among apprentices was 3.7 per 200 000 hours worked (95% confidence interval (CI) 2.7 to 4.9) compared with a rate of 1.2 among journeymen (95% CI 0.80 to 1.7). While not always the sole contributing factor, a sequential trigger would have likely prevented 65% of the injuries from tools with contact trip triggers. Conclusions: Training, engineering, and policy changes in the workplace and manufacturing arena are all appropriate targets for prevention of these injuries. Use of sequential triggers would likely decrease acute injury rates markedly. Over 70% of injuries among residential carpenters were associated with through nailing tasks (such as nailing studs or blocks, trusses or joists) or toe nailing (angled, corner nailing) as opposed to flat nailing used for sheathing activities; this provides some indication that contact trip tools could be used solely for flat nailing. PMID:12642553

  5. Bilateral double level tibial lengthening in dwarfism.

    PubMed

    Burghardt, Rolf D; Yoshino, Koichi; Kashiwagi, Naoya; Yoshino, Shigeo; Bhave, Anil; Paley, Dror; Herzenberg, John E

    2015-12-01

    Outcome assessment after double level tibial lengthening in patients with dwarfism. Fourteen patients with dwarfism were analyzed after bilateral simultaneous double level tibial lengthening. Average age was 15.1 years. Average lengthening was 13.5 cm. The two levels were lengthened by an average of 7.5 cm proximally and 6.0 cm distally. Concomitant deformities were also addressed during lengthening. External fixation treatment time averaged 8.8 months. Healing index averaged 0.7 months/cm. Bilateral tibial lengthening for dwarfism is difficult, but the results are usually quite gratifying.

  6. Minimizing Alteration of Posterior Tibial Slope During Opening Wedge High Tibial Osteotomy: a Protocol with Experimental Validation in Paired Cadaveric Knees

    PubMed Central

    Westermann, Robert W; DeBerardino, Thomas; Amendola, Annunziato

    2014-01-01

    Introduction The High Tibial Osteotomy (HTO) is a reliable procedure in addressing uni- compartmental arthritis with associated coronal deformities. With osteotomy of the proximal tibia, there is a risk of altering the tibial slope in the sagittal plane. Surgical techniques continue to evolve with trends towards procedure reproducibility and simplification. We evaluated a modification of the Arthrex iBalance technique in 18 paired cadaveric knees with the goals of maintaining sagittal slope, increasing procedure efficiency, and decreasing use of intraoperative fluoroscopy. Methods Nine paired cadaveric knees (18 legs) underwent iBalance medial opening wedge high tibial osteotomies. In each pair, the right knee underwent an HTO using the modified technique, while all left knees underwent the traditional technique. Independent observers evaluated postoperative factors including tibial slope, placement of hinge pin, and implant placement. Specimens were then dissected to evaluate for any gross muscle, nerve or vessel injury. Results Changes to posterior tibial slope were similar using each technique. The change in slope in traditional iBalance technique was -0.3° ±2.3° and change in tibial slope using the modified iBalance technique was -0.4° ±2.3° (p=0.29). Furthermore, we detected no differences in posterior tibial slope between preoperative and postoperative specimens (p=0.74 traditional, p=0.75 modified). No differences in implant placement were detected between traditional and modified techniques. (p=0.85). No intraoperative iatrogenic complications (i.e. lateral cortex fracture, blood vessel or nerve injury) were observed in either group after gross dissection. Discussion & Conclusions Alterations in posterior tibial slope are associated with HTOs. Both traditional and modified iBalance techniques appear reliable in coronal plane corrections without changing posterior tibial slope. The present modification of the Arthrex iBalance technique may increase the

  7. Proximal tibial osteotomy. A survivorship analysis.

    PubMed

    Ritter, M A; Fechtman, R A

    1988-01-01

    Proximal tibial osteotomy is generally accepted as a treatment for the patient with unicompartmental arthritis. However, a few reports of the long-term results of this procedure are available in the literature, and none have used the technique known as survivorship analysis. This technique has an advantage over conventional analysis because it does not exclude patients for inadequate follow-up, loss to follow-up, or patient death. In this study, survivorship analysis was applied to 78 proximal tibial osteotomies, performed exclusively by the senior author for the correction of a preoperative varus deformity, and a survival curve was constructed. It was concluded that the reliable longevity of the proximal tibial osteotomy is approximately 6 years.

  8. Compartment syndrome after tibial plateau fracture☆

    PubMed Central

    Pitta, Guilherme Benjamin Brandão; dos Santos, Thays Fernanda Avelino; dos Santos, Fernanda Thaysa Avelino; da Costa Filho, Edelson Moreira

    2014-01-01

    Fractures of the tibial plateau are relatively rare, representing around 1.2% of all fractures. The tibia, due to its subcutaneous location and poor muscle coverage, is exposed and suffers large numbers of traumas, not only fractures, but also crush injuries and severe bruising, among others, which at any given moment, could lead compartment syndrome in the patient. The case is reported of a 58-year-old patient who, following a tibial plateau fracture, presented compartment syndrome of the leg and was submitted to decompressive fasciotomy of the four right compartments. After osteosynthesis with internal fixation of the tibial plateau using an L-plate, the patient again developed compartment syndrome. PMID:26229779

  9. 76 FR 29266 - Certain Steel Nails From the United Arab Emirates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-20

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 Preliminary] Certain Steel Nails... Emirates of certain steel nails, provided for in subheadings 7317.00.55, 7317.00.65 and 7317.00.75 of the... threatened with material injury by reason of LTFV imports of certain steel nails from the United Arab...

  10. Comparative study between biologic plating and intramedullary nailing for the treatment of subtrochanteric fractures: Is biologic plating using LCP-DF superior to intramedullary nailing?

    PubMed

    Shin, Won Chul; Moon, Nam Hoon; Jang, Jae Hoon; Lee, Hee Jin; Suh, Kuen Tak

    2017-10-01

    The objective of this study is to evaluate the outcome measures of subtrochanteric fractures between biologic plating and intramedullary nailing and determine if biologic plating is superior to intramedullary nailing. Between March 2009 and December 2015, 81 patients with subtrochanteric fractures were enrolled (52 males and 29 females; 31 treated with biologic plating and 50 with intramedullary nailing). Biologic plating was conducted consecutively between May 2011 and March 2013 and intramedullary nailing was performed for the rest of period. Perioperative outcomes including operation time and blood loss during the operation; postoperative radiologic outcomes including union, time to union, coronal alignment, and shortening of the femur; and clinical outcomes including walking ability and pain were evaluated. The biologic plating group was compared with the intramedullary nailing group as a historical control. No significant differences were identified for bony union and time to union between the two different fixation methods Coronal alignment was significantly better in the biologic plating group than in the intramedullary nailing group (p<0.016). Postoperative coronal alignment was the only risk factor associated with the nonunion of subtrochanteric fractures (unadjusted OR: 1.915, 95% CI: 0.190 - 19.273; adjusted OR: 0.042, 95% CI: 0.000 - 21.517; p=0.320). Surgical outcomes using LCP-DF are comparable to those using intramedullary nailing. Further clinical studies with a larger sample size are required to show the advantage of biologic plating for the treatment of subtrochanteric fractures. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Brown Nail-bed Arcs and Chronic Renal Disease

    PubMed Central

    Stewart, W. K.; Raffle, E. J.

    1972-01-01

    A brown arc affecting the distal part of the fingernail-bed, just proximal to the point of separation of the nail from its bed, has been found in 12 out of 34 patients with chronic renal disease (35%) compared with an incidence of less than 2% in a series of unselected patients. It represents a distinctive form of pigmentation, possibly due to lipochromes. No decisive association could be found between the presence or absence of the pigmented nail arc and the level of impaired renal function. Nevertheless it seems that renal disease predisposes towards the development of brown nail arcs. Imagesp786-a PMID:5014252

  12. Application of Soil Nailing Technique for Protection and Preservation Historical Buildings

    NASA Astrophysics Data System (ADS)

    Kulczykowski, Marek; Przewłócki, Jarosław; Konarzewska, Bogusława

    2017-10-01

    Soil nailing is one of the recent in situ techniques used for soil improvement and in stabilizing slopes. The process of soil nailing consists of reinforcing the natural ground with relatively small steel bars or metal rods, grouted in the pre-drilled holes. This method has a wide range of applications for stabilizing deep excavations and steep slopes. Soil nailing has recently become a very common method of slope stabilisation especially where situated beneath or adjacent to historical buildings. Stabilisation by nails drilled into existing masonry structures such as failing retaining walls abutments, provide long term stability without demolition and rebuilding costs. Two cases of soil nailing technology aimed at stabilising slopes beneath old buildings in Poland are presented in this paper. The first concerns application of this technology to repair a retaining wall supporting the base of the dam at the historic hydroelectric power plant in Rutki. The second regards a concept of improving the slope of the Castle Hill in Sandomierz. An analysis of the slope stability for the latter case, using stabilisation technique with the piling system and soil nailing was performed. Some advantages of soil nailing especially for protection of historical buildings, are also underlined. And, the main results of an economic comparison analysis are additionally presented.

  13. The floating knee: a review on ipsilateral femoral and tibial fractures

    PubMed Central

    Muñoz Vives, Josep; Bel, Jean-Christophe; Capel Agundez, Arantxa; Chana Rodríguez, Francisco; Palomo Traver, José; Schultz-Larsen, Morten; Tosounidis, Theodoros

    2016-01-01

    In 1975, Blake and McBryde established the concept of ‘floating knee’ to describe ipsilateral fractures of the femur and tibia.1 This combination is much more than a bone lesion; the mechanism is usually a high-energy trauma in a patient with multiple injuries and a myriad of other lesions. After initial evaluation patients should be categorised, and only stable patients should undergo immediate reduction and internal fixation with the rest receiving external fixation. Definitive internal fixation of both bones yields the best results in almost all series. Nailing of both bones is the optimal fixation when both fractures (femoral and tibial) are extra-articular. Plates are the ‘standard of care’ in cases with articular fractures. A combination of implants are required by 40% of floating knees. Associated ligamentous and meniscal lesions are common, but may be irrelevant in the case of an intra-articular fracture which gives the worst prognosis for this type of lesion. Cite this article: Muñoz Vives K, Bel J-C, Capel Agundez A, Chana Rodríguez F, Palomo Traver J, Schultz-Larsen M, Tosounidis, T. The floating knee. EFORT Open Rev 2016;1:375-382. DOI: 10.1302/2058-5241.1.000042. PMID:28461916

  14. Nail haemorrhages in native highlanders of the Peruvian Andes

    PubMed Central

    Heath, Donald; Harris, Peter; Williams, David; Krüger, Hever

    1981-01-01

    Nail haemorrhages are of interest to the chest physician and cardiologist. While the common type in the distal part of the nail is produced by the minor trauma of daily life, the rarer form—scattered through the nail substance—appears to be related to hypoxaemia brought about by heart and lung disease. We thought it would be of interest to study a population which was naturally hypoxaemic because of living at high altitude. Accordingly we have studied the frequency and types of nail haemorrhage in Quechua Indians who are permanently exposed to the hypobaric hypoxia of the Andes. We found the haemorrhages to be common both in mestizos living on the coastal plain and in the native highlanders. They appeared to increase in frequency with altitude but were of the distal type and would thus seem to be the result of minor trauma as at sea level. However, just as in cases of cyanotic congenital heart disease at low altitude, those with exaggerated hypoxaemia and pronounced elevation of haematocrit—namely, subjects with Monge's disease (chronic mountain sickness)—had scattered haemorrhages in the nail substance. Images

  15. Effects of nail polish on microbial growth of fingernails. Dispelling sacred cows.

    PubMed

    Baumgardner, C A; Maragos, C S; Walz, J; Larson, E

    1993-07-01

    Nail polish worn on short, healthy nails does not appear to be associated with increased microbial counts on the fingernails. Additional studies to examine the effect of wearing nail polish on other aspects of hand hygiene may be warranted, however.

  16. High tibial osteotomy in knee laxities: Concepts review and results

    PubMed Central

    Robin, Jonathan G.; Neyret, Philippe

    2016-01-01

    Patients with unstable, malaligned knees often present a challenging management scenario, and careful attention must be paid to the clinical history and examination to determine the priorities of treatment. Isolated knee instability treated with ligament reconstruction and isolated knee malalignment treated with periarticular osteotomy have both been well studied in the past. More recently, the effects of high tibial osteotomy on knee instability have been studied. Lateral closing-wedge high tibial osteotomy tends to reduce the posterior tibial slope, which has a stabilising effect on anterior tibial instability that occurs with ACL deficiency. Medial opening-wedge high tibial osteotomy tends to increase the posterior tibia slope, which has a stabilising effect in posterior tibial instability that occurs with PCL deficiency. Overall results from recent studies indicate that there is a role for combined ligament reconstruction and periarticular knee osteotomy. The use of high tibial osteotomy has been able to extend the indication for ligament reconstruction which, when combined, may ultimately halt the evolution of arthritis and preserve their natural knee joint for a longer period of time. Cite this article: Robin JG, Neyret P. High tibial osteotomy in knee laxities: Concepts review and results. EFORT Open Rev 2016;1:3-11. doi: 10.1302/2058-5241.1.000001. PMID:28461908

  17. Outcomes following femoral lengthening: An initial comparison of the Precice intramedullary lengthening nail and the LRS external fixator monorail system.

    PubMed

    Laubscher, M; Mitchell, C; Timms, A; Goodier, D; Calder, P

    2016-10-01

    Patients undergoing femoral lengthening by external fixation tolerate treatment less well when compared to tibial lengthening. Lengthening of the femur with an intramedullary device may have advantages. We reviewed all cases of simple femoral lengthening performed at our unit from 2009 to 2014. Cases of nonunions, concurrent deformities, congenital limb deficiencies and lengthening with an unstable hip were excluded, leaving 33 cases (in 22 patients; 11 patients had bilateral procedures) for review. Healing index, implant tolerance and complications were compared. In 20 cases (15 patients) the Precice lengthening nail was used and in 13 cases (seven patients) the LRS external fixator system. The desired length was achieved in all cases in the Precice group and in 12 of 13 cases in the LRS group. The mean healing index was 31.3 days/cm in the Precice and 47.1 days/cm in the LRS group (p < 0.001). This was associated with an earlier ability to bear full weight without aids in the Precice group. There were more complications with LRS lengthening, including pin site infections and regenerate deformity. Implant tolerance and the patients' perception of the cosmetic result were better with the Precice treatment. Femoral lengthening with the Precice femoral nail achieved excellent functional results with fewer complications and greater patient satisfaction when compared with the LRS system in our patients. Cite this article: Bone Joint J 2016;98-B:1382-8. ©2016 The British Editorial Society of Bone & Joint Surgery.

  18. Histological Analysis of the Tibial Anterior Cruciate Ligament Insertion

    PubMed Central

    Siebold, Rainer; Oka, Shinya; Traut, Ulrike; Schuhmacher, Peter; Kirsch, Joachim

    2017-01-01

    Objective: To describe the morphology of the tibial ACL insertion by histological assessment in the sagittal plane. Methods: For histology the native (undissected) tibial ACL insertion of 6 fresh-frozen cadaveric knees was cut into 4 sagittal sections parallel to the long axis of the medial tibial spine. The slices were stained with hematoxylin and eosin, Safranin O and Russell-Movat pentachrome. All slices were digitalized and analyzed at a magnification of ×20. Results: From medial to lateral the anterior-posterior lengths of the ACL insertion were an average of 10.2, 9.3, 7.6 and 5.8 mm. The anterior margin of the tibial ACL insertion raised from an anterior ridge. The most medial ACL fibers rose along with a peak of the anterior part of the medial tibial spine in which the direct insertion was adjacent to the articular cartilage. Parts of the bony insertions of the anterior and posterior horns of the lateral meniscus were in close contact to the lateral ACL insertion. A small fat pad was located just posterior to the tibial ACL insertion. There were no central or posterolateral inserting ACL fibers in the area intercondylaris anterior. Conclusion: The functional intraligamentous midsubstance ACL fibers arose from the most posterior part of its bony tibial insertion in a flat and “C-shape” way. The anterior border of this functional ACL started from a bony ‘anterior ridge’ and the medial border was along with a peak of the medial tibial spine.

  19. The use of intramedullary nails in tibiotalocalcaneal arthrodesis.

    PubMed

    Thomas, Ruth L; Sathe, Vinayak; Habib, Syed I

    2012-01-01

    Tibiotalocalcaneal arthrodesis is a salvage procedure undertaken for hindfoot problems that affect both the ankle and subtalar joints (eg, two-joint arthritis, severe acute trauma, osteonecrosis of the talus, severe malalignment deformities, significant hindfoot bone loss). Methods of achieving fusion include Steinmann pins, screws, plates, external fixators, and retrograde intramedullary nailing. Retrograde intramedullary nailing provides a load-sharing fixation device with superior biomechanical properties and is an excellent choice for use in tibiotalocalcaneal arthrodesis. This technique can be performed through relatively small incisions. In addition, recent design modifications include the availability of dynamization and the choice of curved or straight nails. Contraindications to the technique include the presence of infection, severe vascular disease, and severe malalignment of the tibia.

  20. Predictive formula for the length of tibial tunnel in anterior crucitate ligament reconstruction.

    PubMed

    Chernchujit, Bancha; Barthel, Thomas

    2009-12-01

    The anterior cruciate ligament (ACL) reconstruction using bone-patellar tendon bone graft is a common procedure in orthopedics. One challenging problem found is a graft-tunnel mismatch. Previous studies have reported the mathematic formula to predict the tibial angle length and angle to avoid graft-tunnel mismatch but these formulas have shown limited predictability. To propose a predictive formula for the length of tibial tunnel and to examine its predictability. Thirty six patients (26 males, 14 females) with ACL injury were included in this study. The preoperativemedial proximal tibial angle was measured. Intraoperatively, the tibial tunnel length and tibial entry point were measured. The postoperative coronal and saggital angle of tibial tunnel were measured from knee radiograph. The data were analysed by using trigonometry correlation and formulate the predictive formula of tibial tunnel length. We found that tibial tunnel length (T) has trigonometric correlation between the location of tibial tunnel entry point (w), coronal angle of tibial tunnel (b), saggital angle of tibial tunnel (a) and the medial proximal tibial slope (c) by using this formula T = Wcos(c)tan(b)/sin(a) This proposed predictive formula can well predict the length of the tibial tunnel at preoperative period to avoid graft-tunnel mismatch.

  1. Evaluating a county-based Healthy nail Salon Recognition Program

    EPA Science Inventory

    To determine whether nail solons that participate in the SF recognition program have reduced measured levels of toluene, methyl methacrylate (MMA), and total volatile organic compounds (TVOC)as compared to nail salons that do not participate. We also evaluated changes in worker ...

  2. [Treatment of multi-segment fracture of complex femoral shaft with instrument-assisted reduction combined with intramedullary interlocking nail fixation].

    PubMed

    Fan, Ke-Jie; Chen, Ke; Ma, Wen-Long; Tian, Ke-Wei; Ye, Ye; Chen, Hong-Gan; Tang, Yan-Feng; Cai, Hong-Min

    2018-05-25

    To investigate the effect of minimally invasive mini-incision and instrumented reduction combined with interlocking intramedullary nailing in the treatment of patients with multi-segment fracture of complex femoral shaft. From January 2013 to January 2016, 32 patients with multiple fractures segments of femoral shaft were treated with instrumentation-assisted reduction combined with interlocking intramedullary nailing, including 22 males and 10 females with an average age of 45 years old ranging 17 to 68 years old. The time from injured to operation was 5 to 10 days with an average of 7 days. After admission, routine tibial tubercle or supracondylar bone traction was performed. The patient's general condition was evaluated, the operation time and intraoperative blood loss were recorded. According to Thorsen femoral fracture morphology evaluation criteria and Hohl knee function evaluation of postoperative efficacy, postoperative fracture healing, complications and postoperative recovery of limb function were observed. All patients were followed up for 6 to 24 months with an average of 12 months. The operative time ranged from 48 to 76 minutes with an average of 67 min. The intraoperative blood loss was 150 to 400 ml with an average of 220 ml. The surgical incisions all achieved grade A healing. The fractures reached the clinical standard of healing. The fracture healing time ranged from 4.2 to 10.8 months with an average of 5.7 months. There were no nonunion, incision infection and internal fixation fracture, failure and other complications. According to Thorsen femoral fracture morphology evaluation criteria, the result was excellent in 28 cases, good in 3 cases, fair in 1 case. According to Hohl knee function evaluation criteria, the result was excellent in 30 cases, good in 2 cases. Instrument-assisted reduction combined with interlocking intramedullary nail fixation is a safe and effective method for the treatment of complex femoral shaft fractures. It has

  3. Avoiding Pitfalls of Tibiotalocalcaneal Nail Malposition With Internal Rotation Axial Heel View.

    PubMed

    Callahan, Ryan; Juliano, Paul; Aydogan, Umur; Clayton, Justin

    2018-04-01

    Tibiotalocalcaneal (TTC) nails are often used for complex hind foot arthrodesis and deformity correction. The natural valgus alignment of the hindfoot creates a challenge to optimum placement of the guidewire and eventual nail with a straight or valgus-curved nail. Five fresh frozen cadavers were used for placement of a TTC guidewire with standard anterior-posterior (AP), lateral, and Harris axial heel views as a reference for proper placement. The limb was then rotated 15°, 30°, and 45° both internally and externally to evaluate the perceived amount of osseous purchase within the calcaneus. The TTC nail was then inserted and dissection was performed to demonstrate proximity of the nail to the sustentaculum tali and neurovascular structures. A 30° internal rotation Harris axial heel view demonstrated the most accurate representation of osseous purchase within the calcaneus with the guidewire and nail placement. When the guidewire was placed with standard imaging the nail was often ultimately placed in close proximity to the sustentaculum tali and neurovascular structures. Careful placement of the guidewire prior to reaming and nail placement should be undertaken to avoid neurovascular injury and to increase osseous purchase. For optimal guidewire placement, the authors suggest using appropriate anatomic landmarks and using a 30° internally rotated Harris axial heel view to verify correct placement. Level V: Expert opinion.

  4. The Hammer-and-Nail Phenomenon in Mathematics Education

    ERIC Educational Resources Information Center

    Lim, Kien H.

    2012-01-01

    This paper uses the hammer-and-nail metaphor to highlight the rigidity and impulsiveness that can be found in student mathematical behaviour. The hammer-and-nail phenomenon can be attributed to two plausible causes: (1) the way the human mind works; and (2) the way mathematics is traditionally taught in school. In this paper, the following aspects…

  5. Models of tibial fracture healing in normal and Nf1-deficient mice.

    PubMed

    Schindeler, Aaron; Morse, Alyson; Harry, Lorraine; Godfrey, Craig; Mikulec, Kathy; McDonald, Michelle; Gasser, Jürg A; Little, David G

    2008-08-01

    Delayed union and nonunion are common complications associated with tibial fractures, particularly in the distal tibia. Existing mouse tibial fracture models are typically closed and middiaphyseal, and thus poorly recapitulate the prevailing conditions following surgery on a human open distal tibial fracture. This report describes our development of two open tibial fracture models in the mouse, where the bone is broken either in the tibial midshaft (mid-diaphysis) or in the distal tibia. Fractures in the distal tibial model showed delayed repair compared to fractures in the tibial midshaft. These tibial fracture models were applied to both wild-type and Nf1-deficient (Nf1+/-) mice. Bone repair has been reported to be exceptionally problematic in human NF1 patients, and these patients can also spontaneously develop tibial nonunions (known as congenital pseudarthrosis of the tibia), which are recalcitrant to even vigorous intervention. pQCT analysis confirmed no fundamental differences in cortical or cancellous bone in Nf1-deficient mouse tibiae compared to wild-type mice. Although no difference in bone healing was seen in the tibial midshaft fracture model, the healing of distal tibial fractures was found to be impaired in Nf1+/- mice. The histological features associated with nonunited Nf1+/- fractures were variable, but included delayed cartilage removal, disproportionate fibrous invasion, insufficient new bone anabolism, and excessive catabolism. These findings imply that the pathology of tibial pseudarthrosis in human NF1 is complex and likely to be multifactorial.

  6. Proximal tibial fracture following anterior cruciate ligament reconstruction surgery: a biomechanical analysis of the tibial tunnel as a stress riser.

    PubMed

    Aldebeyan, Wassim; Liddell, Antony; Steffen, Thomas; Beckman, Lorne; Martineau, Paul A

    2017-08-01

    This is the first biomechanical study to examine the potential stress riser effect of the tibial tunnel or tunnels after ACL reconstruction surgery. In keeping with literature, the primary hypothesis tested in this study was that the tibial tunnel acts as a stress riser for fracture propagation. Secondary hypotheses were that the stress riser effect increases with the size of the tunnel (8 vs. 10 mm), the orientation of the tunnel [standard (STT) vs. modified transtibial (MTT)], and with the number of tunnels (1 vs. 2). Tibial tunnels simulating both single bundle hamstring graft (8 mm) and bone-patellar tendon-bone graft (10 mm) either STT or MTT position, as well as tunnels simulating double bundle (DB) ACL reconstruction (7, 6 mm), were drilled in fourth-generation saw bones. These five experimental groups and a control group consisting of native saw bones without tunnels were loaded to failure on a Materials Testing System to simulate tibial plateau fracture. There were no statistically significant differences in peak load to failure between any of the groups, including the control group. The fracture occurred through the tibial tunnel in 100 % of the MTT tunnels (8 and 10 mm) and 80 % of the DB tunnels specimens; however, the fractures never (0 %) occurred through the tibial tunnel of the standard tunnels (8 or 10 mm) (P = 0.032). In the biomechanical model, the tibial tunnel does not appear to be a stress riser for fracture propagation, despite suggestions to the contrary in the literature. Use of a standard, more vertical tunnel decreases the risk of ACL graft compromise in the event of a fracture. This may help to inform surgical decision making on ACL reconstruction technique.

  7. Management of comminuted proximal ulna fracture-dislocations using a multiplanar locking intramedullary nail.

    PubMed

    Edwards, Scott G; Argintar, Evan; Lamb, Joshua

    2011-06-01

    Intramedullary nails have been used for the fixation of olecranon fractures in an attempt to reduce the soft tissue irritation and resulting need for hardware removal seen with plating and tension banding. Further benefits include preservation of vascular supply, and increase stability and improved compression over some alternative techniques. Most intramedullary nails have been limited to simple olecranon fractures or osteotomies. One novel multiplanar, locking intramedullary nail, however, is indicated to stabilize all fracture patterns of the proximal ulna, including the coronoid. This particular locking nail has screws that radiate in multiple planes and form a fixed-angle lattice throughout the bone. The nail also has fixed-angle screws dedicated to the 3 parts of the coronoid: process tip, medial facet, and medial wall. This allows the nail to secure multiple fragments regardless of the fracture pattern's extent of instability. The objective of this article is to illustrate the recommended steps in reducing and stabilizing a comminuted proximal ulna fracture-dislocation using this multiplanar locking intramedullary nail.

  8. Treatment of psoriatic nails with indigo naturalis oil extract: a non-controlled pilot study.

    PubMed

    Lin, Yin-Ku; See, Lai-Chu; Chang, Ya-Ching; Huang, Yu-Huei; Chen, Jiun-Liang; Tsou, Teng-Cheng; Leu, Yann-Lii; Shen, Yu-Ming

    2011-01-01

    In the treatment of nail psoriasis, standardized therapeutic regimens are currently lacking. To evaluate the therapeutic efficacy of indigo naturalis oil extract in patients with nail psoriasis. Patients with nail psoriasis applied indigo naturalis oil extract on affected nails twice daily for 24 weeks. Efficacy was evaluated using the Nail Psoriasis Severity Index (NAPSI) and modified target NAPSI for the single most severely affected nail. Twenty-eight out of 32 patients completed the study. The mean NAPSI was 36.1 ± 14.7 at baseline and decreased to 14.9 ± 11.1 at week 24 while the mean modified target NAPSI was 11.7 ± 3.9 at baseline and decreased to 3.6 ± 3.2 at week 24. Indigo naturalis oil extract appeared to improve nail psoriasis. Although preliminary, these results indicate that it could provide a novel therapeutic option for nail psoriasis, a disease notoriously difficult to treat. Copyright © 2011 S. Karger AG, Basel.

  9. Withdrawal strength of ring-shank nails embedded in southern pine lumber

    Treesearch

    M. J. Skulteti; D. A. Bender; S. G. Winistorfer; D. G. Pollock

    1997-01-01

    Ring-shank nails are used extensively in post-frame construction due to their superior performance, yet surprisingly little testing has been done on nail sizes above 12d Experience in the post-frame industry suggests that published allowable design values for ring-shank nails may be overly conservative and need revision. The goal of the research reported herein was to...

  10. Nail gun injuries to the head with minimal neurological consequences: a case series.

    PubMed

    Makoshi, Ziyad; AlKherayf, Fahad; Da Silva, Vasco; Lesiuk, Howard

    2016-03-16

    An estimated 3700 individuals are seen annually in US emergency departments for nail gun-related injuries. Approximately 45 cases have been reported in the literature concerning nail gun injuries penetrating the cranium. These cases pose a challenge for the neurosurgeon because of the uniqueness of each case, the dynamics of high pressure nail gun injuries, and the surgical planning to remove the foreign body without further vascular injury or uncontrolled intracranial hemorrhage. Here we present four cases of penetrating nail gun injuries with variable presentations. Case 1 is of a 33-year-old white man who sustained 10 nail gunshot injuries to his head. Case 2 is of a 51-year-old white man who sustained bi-temporal nail gun injuries to his head. Cases 3 and 4 are of two white men aged 22 years and 49 years with a single nail gun injury to the head. In the context of these individual cases and a review of similar cases in the literature we present surgical approaches and considerations in the management of nail gun injuries to the cranium. Case 1 presented with cranial nerve deficits, Case 2 required intubation for low Glasgow Coma Scale, while Cases 3 and 4 were neurologically intact on presentation. Three patients underwent angiography for assessment of vascular injury and all patients underwent surgical removal of foreign objects using a vice-grip. No neurological deficits were found in these patients on follow-up. Nail gun injuries can present with variable clinical status; mortality and morbidity is low for surgically managed isolated nail gun-related injuries to the head. The current case series describes the surgical use of a vice-grip for a good grip of the nail head and controlled extraction, and these patients appear to have a good postoperative prognosis with minimal neurological deficits postoperatively and on follow-up.

  11. Measurement of Posterior Tibial Slope Using Magnetic Resonance Imaging.

    PubMed

    Karimi, Elham; Norouzian, Mohsen; Birjandinejad, Ali; Zandi, Reza; Makhmalbaf, Hadi

    2017-11-01

    Posterior tibial slope (PTS) is an important factor in the knee joint biomechanics and one of the bone features, which affects knee joint stability. Posterior tibial slope has impact on flexion gap, knee joint stability and posterior femoral rollback that are related to wide range of knee motion. During high tibial osteotomy and total knee arthroplasty (TKA) surgery, proper retaining the mechanical and anatomical axis is important. The aim of this study was to evaluate the value of posterior tibial slope in medial and lateral compartments of tibial plateau and to assess the relationship among the slope with age, gender and other variables of tibial plateau surface. This descriptive study was conducted on 132 healthy knees (80 males and 52 females) with a mean age of 38.26±11.45 (20-60 years) at Imam Reza hospital in Mashhad, Iran. All patients, selected and enrolled for MRI in this study, were admitted for knee pain with uncertain clinical history. According to initial physical knee examinations the study subjects were reported healthy. The mean posterior tibial slope was 7.78± 2.48 degrees in the medial compartment and 6.85± 2.24 degrees in lateral compartment. No significant correlation was found between age and gender with posterior tibial slope ( P ≥0.05), but there was significant relationship among PTS with mediolateral width, plateau area and medial plateau. Comparison of different studies revealed that the PTS value in our study is different from other communities, which can be associated with genetic and racial factors. The results of our study are useful to PTS reconstruction in surgeries.

  12. Nail disorders in older people, and aspects of their pharmaceutical treatment.

    PubMed

    Murdan, Sudaxshina

    2016-10-30

    The aim of this paper was to explore how aging influences the nail unit, its disorders and its response to treatment, and to identify some of the age-related gaps in the ungual drug delivery literature. Aging causes obvious changes to the nail, some of which are inherently due to old age, while others are due to diseases/conditions which become more prevalent as we age. Alterations in the nail plate's colour, contour, thickness, fragility, surface features, cell size, chemical composition and growth rate are some of the changes, with toenails and fingernails showing different effects. With respect to disease, the incidence of onychomycosis - the most common nail disorder - is considerably higher in older people. Similarly, brittle nails become more common as we age. In contrast, the literature about aging and the incidence of nail psoriasis is inconclusive, although, it is clear that as one gets older, the negative impact of nail psoriasis on one's quality of life decreases. Pharmaceutical treatment of the diseases comprises local and systemic therapies, sometimes in combination. Systemic therapies have the inherent disadvantages of adverse systemic effects, drug interactions and the need for monitoring, disadvantages which are especially problematic for older people who are more likely to suffer from co-morbidities and be on other medications. Topical therapy avoids such disadvantages. However, the success rates of commercially available preparations are low, and older people may need help with their application. It is also proposed that regular inspection and grooming of nails should become part of routine care of older people, as these would provide opportunities to identify and treat any problems at an earlier stage. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Investigating relations among stress, sleep and nail cortisol and DHEA.

    PubMed

    Doan, Stacey N; DeYoung, Gerrit; Fuller-Rowell, Thomas E; Liu, Cindy; Meyer, Jerrold

    2018-03-01

    In the current study, we present data investigating the relationships among stress, sleep disturbance, self-control, and levels of cortisol (CORT) and dehydroepiandrosterone (DHEA) in fingernail clippings. Currently, hair CORT is the only routinely used noninvasive, validated, biomarker of chronic exposure to stress-related hormones. Nail clippings represent an important potential alternative sample matrix for assessing chronic hormone exposure, as it offers a different timeline of hormone incorporation than scalp hair, and may be obtainable from populations in which hair either is lacking or is unavailable for cultural reasons. Moreover, there is established precedent for using fingernail clippings to attain biomarker data. However, the value of nail hormone assessment for psychological research is currently unknown due to a paucity of information on the relations between nail hormone concentrations and environmental or psychological variables. In the present study, we collected data from a low income, minority population (N = 47; 97% African American) to demonstrate feasibility and acceptability of nail collection and analysis of the adrenal steroids CORT and DHEA. Participants reported on perceived stress, sleep and self-control abilities. Correlational analyses suggest that exposure to stressful events, disturbances in sleep and waking were associated with higher levels of nail DHEA, while self-control was associated with higher levels of nail CORT. We discuss the potential importance of this methodology for investigating biological, behavioral, and subjective indices of stress and well-being.

  14. Neurovascular Structures at Risk With Curved Retrograde TTC Fusion Nails.

    PubMed

    de Cesar Netto, Cesar; Johannesmeyer, David; Cone, Brent; Araoye, Ibukunoluwa; Hudson, Parke William; Sahranavard, Bahman; Johnson, Michael; Shah, Ashish

    2017-10-01

    The purpose of this study was to assess the risk of iatrogenic injury to plantar neurovascular structures of the foot during insertion of a curved retrograde tibiotalocalcaneal (TTC) fusion nail. Ten below-knee thawed fresh-frozen cadaveric specimens underwent curved retrograde nailing of the ankle. The shortest distance between the nail and the main plantar neurovascular branches and injured structures were recorded during dissection. We also evaluated the relative position of these structures along 2 lines (AB, connecting the calcaneus to the first metatarsal, and BC, connecting the first and fifth metatarsal). The lateral plantar artery was found to be in direct contact with the nail 70% of the time, with a macroscopic laceration 30% of the time. The Baxter nerve was injured 20% of the time, as was the lateral plantar nerve. The medial plantar artery and nerve were never injured. The most proximal structure to cross line AB was the Baxter nerve followed by the lateral plantar artery, the nail, the lateral plantar nerve, and the medial plantar nerve. Our cadaveric anatomic study found that the most common structures at risk for iatrogenic injury by lateral curved retrograde TTC fusion nails were the lateral plantar artery and nerve, and the Baxter nerve. Determination of a true neurovascular safe zone is challenging and therefore warrants careful operative dissection to minimize neurovascular injuries.

  15. Rapid Treatment of Subungual Onychomycosis Using Controlled Micro Nail Penetration and Terbinafine Solution.

    PubMed

    Bristow, Ivan; Baran, Robert; Score, Michelle

    2016-08-01

    Onychomycosis continues to be a common and intractable problem in adults, often responding poorly to topical treatment due to limited drug penetration of the nail plate. Improving penetration has been attempted previously by chemical and physical means with some success. The authors present three cases of toenail onychomycosis treated topical terbinafine 1% solution using controlled micro-penetration of the nail using a novel intelligent nail drill system which is able to drill nail plate without penetrating the delicate nail bed beneath. The cases illustrate how the device has been successfully employed to deliver the anti-fungal drug directly and rapidly to the site of infection with minimal side effects or complications, whilst maintaining the nail integrity.

    J Drugs Dermatol. 2016;15(8):974-978.

  16. Tibial Stress Injuries: Decisive Diagnosis and Treatment of "Shin Splints."

    ERIC Educational Resources Information Center

    Couture, Christopher J.; Karlson, Kristine A.

    2002-01-01

    Tibial stress injuries, commonly called shin splints, often result when bone remodeling processes adopt inadequately to repetitive stress. Physicians who are caring for athletic patients must have a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are…

  17. Tibial Eminence Involvement With Tibial Plateau Fracture Predicts Slower Recovery and Worse Postoperative Range of Knee Motion.

    PubMed

    Konda, Sanjit R; Driesman, Adam; Manoli, Arthur; Davidovitch, Roy I; Egol, Kenneth A

    2017-07-01

    To examine 1-year functional and clinical outcomes in patients with tibial plateau fractures with tibial eminence involvement. Retrospective analysis of prospectively collected data. Academic Medical Center. All patients who presented with a tibial plateau fracture (Orthopaedic Trauma Association (OTA) 41-B and 41-C). Patients were divided into fractures with a tibial eminence component (+TE) and those without (-TE) cohorts. All patients underwent similar surgical approaches and fixation techniques for fractures. No tibial eminence fractures received fixation specifically. Short musculoskeletal functional assessment (SMFA), pain (Visual Analogue Scale), and knee range-of-motion (ROM) were evaluated at 3, 6, and 12 months postoperatively and compared between cohorts. Two hundred ninety-three patients were included for review. Patients with OTA 41-C fractures were more likely to have an associated TE compared with 41-B fractures (63% vs. 28%, P < 0.01). At 3 months postoperatively, the +TE cohort was noted to have worse knee ROM (75.16 ± 51 vs. 86.82 ± 53 degree, P = 0.06). At 6 months, total SMFA and knee ROM was significantly worse in the +TE cohort (29 ± 17 vs. 21 ± 18, P ≤ 0.01; 115.6 ± 20 vs. 124.1 ± 15, P = 0.01). By 12 months postoperatively, only knee ROM remained significantly worse in the +TE cohort (118.7 ± 15 vs. 126.9 ± 13, P < 0.01). Multivariate analysis revealed that tibial eminence involvement was a significant predictor of ROM at 6 and 12 months and SFMA at 6 months. Body mass index was found to be a significant predictor of ROM and age was a significant predictor of total SMFA at all time points. Knee ROM remains worse throughout the postoperative period in the +TE cohort. Functional outcome improves less rapidly in the +TE cohort but achieves similar results by 1 year. Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.

  18. CalNail : a design tool for soil nail projects using field case histories.

    DOT National Transportation Integrated Search

    2006-06-01

    Currently, geotechnical staff within Caltrans do not have ready access to detailed information on : previously designed soil nail walls. Much of this information is kept by individual designers, or stored in : paper format, with no organized method o...

  19. Complications of tibio-talar-calcaneal fusion using intramedullary nails.

    PubMed

    Fenton, P; Bali, N; Matheshwari, R; Youssef, B; Meda, K

    2014-12-01

    Hindfoot nails are being increasingly used, however significant complications can occur. The purpose of this study was to assess the complications following the use of hindfoot nails at our institution. We identified patients from a retrospective database. All underwent hindfoot nailing under the care of the senior author. Details of complications were recorded. We identified 52 patients undergoing 55 procedures. Mean follow up was 44.8 months (18-69). Forty patients achieved ankle fusion and 36 subtalar joint fusion. Complications included prominent metalwork in 13 patients, CRPS in five and one peri-prosthetic fracture. Nine developed deep infection, and of these limb salvage was achieved in six patients by removal of metalwork, debridement and insertion of antibiotic loaded cement beads. The remaining three patients underwent below knee amputation. Significant complications can occur, although limb preservation was possible in most cases of deep infection. Hindfoot nailing should be reserved as salvage procedure. Copyright © 2014 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  20. Arthrodesis in septic knees using a long intramedullary nail: 17 consecutive cases.

    PubMed

    Leroux, B; Aparicio, G; Fontanin, N; Ohl, X; Madi, K; Dehoux, E; Diallo, S

    2013-06-01

    Intramedullary nailing using long or modular nails is the most reliable mean of achieving femorotibial fusion. Here, we report the operative, clinical, functional, and radiological outcomes of 17 long intramedullary nail arthodeses in patients with infection. Clinical and functional outcomes after long intramedullary nailing are at least as good as those obtained using other implants. We retrospectively reevaluated 17 patients after unilateral two-stage knee arthrodesis with a long titanium intramedullary nail and autologous bone grafting. We evaluated satisfaction, leg length discrepancy, and function (Lequesne and WOMAC indices). Radiographs were obtained to assess fusion, time to fusion, and femorotibial angles. No cases of material failure were recorded. One or more complications occurred in seven patients. Mean limb shortening was 27.6mm. Of the 17 patients, 15 were satisfied with the procedure. The mean Lequesne index was 10.5/24 and the mean overall WOMAC score was 26/88. Fusion was achieved in 16 patients, with a mean time to fusion of 5 months. Mean femorotibial angles were 178.6° of varus and 1.9° of flexion. This simple and rapid surgical technique provides functional outcomes similar to those obtained using modular nails. The fusion rate is high. Nail extraction is simple and causes minimal damage, in contrast to modular nails. Increased attention to misalignment is needed. Level IV, retrospective study. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  1. Medial tibial plateau morphology and stress fracture location: A magnetic resonance imaging study.

    PubMed

    Yukata, Kiminori; Yamanaka, Issei; Ueda, Yuzuru; Nakai, Sho; Ogasa, Hiroyoshi; Oishi, Yosuke; Hamawaki, Jun-Ichi

    2017-06-18

    To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 15-50 years)], who underwent knee MRI, were included. The appearance of the tibial plateau stress fracture and the geometry of the tibial plateau were reviewed and measured on MRI. Thirteen of 14 stress fractures were linear, and one of them stellated on MRI images. The location of fractures was classified into three types. Three fractures were located anteromedially (AM type), six posteromedially (PM type), and five posteriorly (P type) at the medial tibial plateau. In addition, tibial posterior slope at the medial tibial plateau tended to be larger when the fracture was located more posteriorly on MRI. We found that MRI showed three different localizations of medial tibial plateau stress fractures, which were associated with tibial posterior slope at the medial tibial plateau.

  2. Medial tibial plateau morphology and stress fracture location: A magnetic resonance imaging study

    PubMed Central

    Yukata, Kiminori; Yamanaka, Issei; Ueda, Yuzuru; Nakai, Sho; Ogasa, Hiroyoshi; Oishi, Yosuke; Hamawaki, Jun-ichi

    2017-01-01

    AIM To determine the location of medial tibial plateau stress fractures and its relationship with tibial plateau morphology using magnetic resonance imaging (MRI). METHODS A retrospective review of patients with a diagnosis of stress fracture of the medial tibial plateau was performed for a 5-year period. Fourteen patients [three female and 11 male, with an average age of 36.4 years (range, 15-50 years)], who underwent knee MRI, were included. The appearance of the tibial plateau stress fracture and the geometry of the tibial plateau were reviewed and measured on MRI. RESULTS Thirteen of 14 stress fractures were linear, and one of them stellated on MRI images. The location of fractures was classified into three types. Three fractures were located anteromedially (AM type), six posteromedially (PM type), and five posteriorly (P type) at the medial tibial plateau. In addition, tibial posterior slope at the medial tibial plateau tended to be larger when the fracture was located more posteriorly on MRI. CONCLUSION We found that MRI showed three different localizations of medial tibial plateau stress fractures, which were associated with tibial posterior slope at the medial tibial plateau. PMID:28660141

  3. Changes in nail keratin observed by Raman spectroscopy after Nd:YAG laser treatment.

    PubMed

    Shin, Min Kyung; Kim, Tae In; Kim, Wan Sun; Park, Hun-Kuk; Kim, Kyung Sook

    2017-04-01

    Lasers and photodynamic therapy have been considered a convergence treatment for onychomycosis, which is a fungal infection on the nail bed and nail plate. Laser therapies have shown satisfactory results without significant complications for onychomycosis; however, the mechanism of clearing remains unknown. In this work, we investigated changes in the chemical structure of nail keratin induced by Nd:YAG laser using Raman spectroscopy. Toe nails with onychomycosis were treated with 1064 nm Nd:YAG laser. After laser treatment, the disulfide band (490-590 cm -1 ) of nail keratin was rarely observed or was reduced in intensity. The amide I band (1500-1700 cm -1 ) also showed changes induced by the laser. The α-helical (1652 cm -1 ) structures dominated the β-sheet (1673 cm -1 ) in nontreated nail, but the opposite phenomenon was observed after laser treatment. © 2016 Wiley Periodicals, Inc.

  4. Jumbo Cutter for Removal of A Bent Femoral Interlocking Nail: A Cost Effective Method

    PubMed Central

    Dhanda, Manjeet Singh; Sharma, Sansar C; Ali, Nadeem; Bhat, Abedullah

    2015-01-01

    Closed diaphyseal femoral shaft fractures can be treated with multiple surgical options. It is more challenging to remove a bent nail than a broken one because it is difficult to retrieve the bent nail through the intramedullary canal. Various authors have published their techniques for removal of bent femoral interlocking nail. This article describes a simple technique using Jumbo cutter for sectioning and removal of bent interlocking nail. This technique will help orthopaedic surgeons to remove bent nail without using any specialised metal cutting instruments. PMID:26266173

  5. Brittle Splitting Nails (Onychoschizia)

    MedlinePlus

    ... be divided into dry and brittle (too little moisture) and soft and brittle (often too much moisture). The usual cause is repeated wetting and drying ... that the nails may be getting too much moisture or being damaged by chemicals such as detergents, ...

  6. Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing.

    PubMed

    Gessmann, Jan; Königshausen, Matthias; Coulibaly, Marlon Osman; Schildhauer, Thomas Armin; Seybold, Dominik

    2016-05-01

    Humeral shaft nonunion after intramedullary nailing is a rare but serious complication. Treatment options include implant removal, open plating, exchange nailing and external fixation. The objective of this retrospective study was to determine whether augmentation plating without nail removal is feasible for treating a humeral shaft nonunion. Between 2002 and 2014, 37 patients (mean age 51, range 20-84 years) with aseptic humeral shaft nonunions prior to intramedullary nailing were treated with augmentation plating. The initial fractures had been fixed with retrograde nails (10 cases) or anterograde nails (27 cases). There were 34 atrophic nonunions and 3 hypertrophic nonunions. Nonunion treatment of all patients consisted of local debridement through an anterior approach to the humerus and anterior placement of the augmentation plates. Supplemental bone grafting was performed in all atrophic nonunion cases. All patients were followed until union was radiologically confirmed. Union was achieved in 36 patients (97 %) after a mean of 6 months (range 3-24 months). There was one case of iatrogenic median nerve palsy that showed complete spontaneous recovery 6 weeks postoperatively. One patient sustained a peri-implant stress fracture that was treated successfully by exchanging the augmentation plate to bridge the nonunion and the fracture. No infections or wound healing complications developed. At a mean follow-up of 14 months, all patients showed free shoulder and elbow motion and no restrictions in daily or working life. The results indicate that augmentation plating using an anterior approach is a safe and reliable option for humeral shaft nonunions after failed nailing, and the treatment has no substantial complications. Because the healing rates are similar to the standard technique of nail removal and fixation by compression or locking plates, we consider this technique to be an alternative choice for treatment.

  7. A Pilot Study: Nailing Indian Elections with the Indelible Ink Mark

    PubMed Central

    Abraham, Anil; Roga, Gillian; Thomas, Naveen

    2015-01-01

    Context: The indelible ink that's used in our elections was developed by National Physical Laboratories (NPL), Delhi in 1962, and has been used ever since. Though formulated by NPL, it is manufactured by Mysore Paints and Varnish Ltd. owned by the Karnataka Government. Earlier, the ink mark was applied on the cuticle but with effect from February 01, 2006 the ink is applied on the voter's left index fingernail from the distal end proximally until the cuticle using an applicator. This idea of the ink mark applied during elections was used as a simple tool to measure the rate of nail growth in a busy outpatient department of a Tertiary Hospital in South India. Aims: To assess the feasibility of using the ink mark during elections as a method of obtaining data of nail growth across the spectrum of the entire country. Subjects and Methods: In 74 patients presenting to a hospital, the rate of nail growth was measured. The voter's mark on the left index fingernail of patients during the recent elections was used as a marker for measuring the length of the nail. Results: The average rate of nail growth was 0.113 mm/day. The rate of nail growth was found to be more in females, younger individuals, pregnancy, patients on nutritional supplementation, psoriasis. Conclusion: This study which was conducted on 74 patients using the election ink mark successfully confirmed the possibility of using it as an efficient tool in measuring the rate of nail growth. The findings revealed the slightly higher rate of nail growth as compared to a study done by Rani et al. However, the limited sample size in this study was the major limitation. PMID:26677268

  8. [Surgical approaches to tibial plateau fractures].

    PubMed

    Krause, Matthias; Müller, Gunnar; Frosch, Karl-Heinz

    2018-06-06

    Intra-articular tibial plateau fractures can present a surgical challenge due to complex injury patterns and compromised soft tissue. The treatment goal is to spare the soft tissue and an anatomical reconstruction of the tibial articular surface. Depending on the course of the fracture, a fracture-specific access strategy is recommended to provide correct positioning of the plate osteosynthesis. While the anterolateral approach is used in the majority of lateral tibial plateau fractures, only one third of the joint surface is visible; however, posterolateral fragments require an individual approach, e. g. posterolateral or posteromedial. If necessary, osteotomy of the femoral epicondyles can improve joint access for reduction control. Injuries to the posterior columns should be anatomically reconstructed and biomechanically correctly addressed via posterior approaches. Bony posterior cruciate ligament tears can be refixed via a minimally invasive posteromedial approach.

  9. Tibial stress injuries: decisive diagnosis and treatment of 'shin splints'.

    PubMed

    Couture, Christopher J; Karlson, Kristine A

    2002-06-01

    Tibial stress injuries, commonly called 'shin splints,' often result when bone remodeling processes adapt inadequately to repetitive stress. Physicians who care for athletic patients need a thorough understanding of this continuum of injuries, including medial tibial stress syndrome and tibial stress fractures, because there are implications for appropriate diagnosis, management, and prevention.

  10. Understanding the etiology of the posteromedial tibial stress fracture.

    PubMed

    Milgrom, Charles; Burr, David B; Finestone, Aharon S; Voloshin, Arkady

    2015-09-01

    Previous human in vivo tibial strain measurements from surface strain gauges during vigorous activities were found to be below the threshold value of repetitive cyclical loading at 2500 microstrain in tension necessary to reduce the fatigue life of bone, based on ex vivo studies. Therefore it has been hypothesized that an intermediate bone remodeling response might play a role in the development of tibial stress fractures. In young adults tibial stress fractures are usually oblique, suggesting that they are the result of failure under shear strain. Strains were measured using surface mounted unstacked 45° rosette strain gauges on the posterior aspect of the flat medial cortex just below the tibial midshaft, in a 48year old male subject while performing vertical jumps, staircase jumps and running up and down stadium stairs. Shear strains approaching 5000 microstrain were recorded during stair jumping and vertical standing jumps. Shear strains above 1250 microstrain were recorded during runs up and down stadium steps. Based on predictions from ex vivo studies, stair and vertical jumping tibial shear strain in the test subject was high enough to potentially produce tibial stress fracture subsequent to repetitive cyclic loading without necessarily requiring an intermediate remodeling response to microdamage. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Reconstruction of large diaphyseal bone defect by simplified bone transport over nail technique: A 7-case series.

    PubMed

    Ferchaud, F; Rony, L; Ducellier, F; Cronier, P; Steiger, V; Hubert, L

    2017-11-01

    Reconstruction of large diaphyseal bone defect is complex and the complications rate is high. This study aimed to assess a simplified technique of segmental bone transport by monorail external fixator over an intramedullary nail.A prospective study included 7 patients: 2 femoral and 5 tibial defects. Mean age was 31years (range: 16-61years). Mean follow-up was 62 months (range: 46-84months). Defects were post-traumatic, with a mean length of 7.2cm (range: 4 to 9.5cm). For 3 patients, reconstruction followed primary failure. In 4 cases, a covering flap was necessary. Transport used an external fixator guided by an intramedullary nail, at a rate of 1mm per day. One pin was implanted on either side of the distraction zone. The external fixator was removed 1 month after bone contact at the docking site. Mean bone transport time was 11 weeks (range: 7-15 weeks). Mean external fixation time was 5.1months (range: 3.5 to 8months). Full weight-bearing was allowed 5.7months (range: 3.5-13months) after initiation of transport. In one patient, a pin had to be repositioned. In 3 patients, the transported segment re-ascended after external fixatorablation, requiring repeat external fixation and resumption of transport. There was just 1 case of superficial pin infection. Reconstruction quality was considered "excellent" on the Paley-Marr criteria in 6 cases. The present technique provided excellent reconstruction quality in 6 of the 7 cases. External fixation time was shorter and resumption of weight-bearing earlier than with other reconstruction techniques, notably including bone autograft, vascularized bone graft or the induced membrane technique. Nailing facilitated control of limb axis and length. The complications rate was 50%, comparable to other techniques. This study raises the question of systematic internal fixation of the docking site, to avoid any mobilization of the transported segment. The bone quality, axial control and rapidity shown by the present technique make

  12. [Respiratory manifestations of yellow nail syndrome: report of two cases and literature review].

    PubMed

    Li, S; Huang, H; Xu, K; Xu, Z J

    2018-03-12

    Objective: To describe the clinical characteristics of respiratory manifestations of yellow nail syndrome. Methods: We conducted a retrospective analysis of 2 patients with respiratory diseases associated with yellow nail syndrome. Their clinical and chest radiological data were collected. We searched PubMed, Wanfang and CNKI databases with the keywords "yellow nail syndrome, yellow nail and lung" in Chinese and English. And the relevant literatures, including 6 articles in Chinese and 81 articles in English, were reviewed. Results: Our 2 patients were male, one 60 years old and the other 76. Typical yellow nails were present in their fingers, and one of them also showed toe yellow nails. One patient was admitted for refractory respiratory infection and he was diagnosed with diffuse bronchiectasis. The respiratory symptoms could be relieved with antibiotics according to the results of sputum microbiological analysis. The other patient was admitted for cough and exertional dyspnea, and refractory pleural effusions were revealed bilaterally. He received repeated effusion drainage by thoracentesis, and Octreotide was tried recently. A total of 373 cases were reviewed in Chinese and English literatures. Pleural effusions (152 cases) and diffuse bronchiectasis (121 cases) were the most common reported respiratory manifestations. Lymphoedema was present in almost all cases with pleural effusion associated with yellow nail syndrome, and the effusion was usually exudative and lymphocyte predominant. Pleurodesis and decortication were effective for them. But, somatostatin analogues had been tried effectively for these patients recently. On the other hand, literatures showed that diffuse bronchiectasis in yellow nail syndrome was less severe than idiopathic diffuse bronchiectasis, and might benefit from long-term macrolide antibiotics. Conclusions: Yellow nail syndrome is a very rare disorder. Besides yellow nail, respiratory manifestations are the main clinical

  13. Chevron nails: a normal variant in the pediatric population.

    PubMed

    Delano, Sofia; Belazarian, Leah

    2014-01-01

    A 7-month-old girl was evaluated for V-shaped ridging of the fingernails consistent with chevron nails. Chevron nails are a normal variant in the pediatric population that is frequently outgrown. This case nicely demonstrates this normal finding that has so rarely been reported in the literature. © 2013 Wiley Periodicals, Inc.

  14. [RESEARCH PROGRESS IN COMPLICATIONS OF RETROGRADE INTRAMEDULLARY NAIL FIXATION FOR TIBIOTALOCALCANEAL ARTHRODESIS].

    PubMed

    Feng, Jun; Yu, Guangrong

    2015-09-01

    To review the cause, treatment, and prevention of complications of retrograde intramedullary nail fixation for tibiotalocalcaneal arthrodesis and enhance the recognition on the complications of tibiotalocalcaneal arthrodesis. The recent literature concerning intramedullary nail fixation for tibiotalocalcaneal arthrodesis was consulted and reviewed. There are intraoperative and postoperative complications of intramedullary nail fixation for tibiotalocalcaneal arthrodesis, and the causes, treatment, and prevention of complications are various. Progress of retrograde intramedullary nail fixation increases the successful rate of tibiotalocalcaneal arthrodesis. However, there is still a high complication rate, so strict preoperative assessment and skilled surgical technique are necessary to prevent complications.

  15. Open unstable metaphyseo-diaphyseal fractures of the tibia in adolescents: treatment by flexible intramedullary nails augmented by external fixator.

    PubMed

    Atef, Ashraf; El Tantawy, Ahmad

    2015-05-01

    The treatment of open and unstable metaphyseo-diaphyseal fractures of the tibia in adolescents is challenging. It is important to choose a fixation method that can maintain alignment, allow wound care and not violate the growth plate. The aim of this work was to evaluate the efficacy of using flexible intramedullary nails (FIN) augmented by external fixator (EF) in the management of such fractures. A total of 26 males, with a mean age of 14.08 years and average body weight of 49.8 kg, presented with open metaphyseo-diaphyseal tibial fractures. All cases were treated using FIN augmented by mono-lateral EF. The fractures were located at the upper third in 17 cases and at the lower third in nine cases. The fracture pattern was spiral in eight cases, oblique in seven and multi-fragmentary in 11. The results were evaluated according to the scoring system for femoral TENs. All fractures united primarily after an average eight to 12 weeks with no evident angular deformity or limb-length discrepancy. None of the cases required cast immobilization or revision procedure. Twenty patients had excellent results, six patients showed good results and none had poor results. Fracture characteristics as well as patients' characteristics had no statistically significant effect (p > 0.005) on the final end results. The use of FIN augmented by EF is a good alternative in the management of open metaphyseo-diaphyseal tibial fractures in adolescents. This fixation provides more stability, allows easy access to the wound and early patients' ambulation.

  16. Outcome of limb reconstruction system in open tibial diaphyseal fractures.

    PubMed

    Ajmera, Anand; Verma, Ankit; Agrawal, Mukul; Jain, Saurabh; Mukherjee, Arunangshu

    2015-01-01

    Management of open tibial diaphyseal fractures with bone loss is a matter of debate. The treatment options range from external fixators, nailing, ring fixators or grafting with or without plastic reconstruction. All the procedures have their own set of complications, like acute docking problems, shortening, difficulty in soft tissue management, chronic infection, increased morbidity, multiple surgeries, longer hospital stay, mal union, nonunion and higher patient dissatisfaction. We evaluated the outcome of the limb reconstruction system (LRS) in the treatment of open fractures of tibial diaphysis with bone loss as a definative mode of treatment to achieve union, as well as limb lengthening, simultaneously. Thirty open fractures of tibial diaphysis with bone loss of at least 4 cm or more with a mean age 32.5 years were treated by using the LRS after debridement. Distraction osteogenesis at rate of 1 mm/day was done away from the fracture site to maintain the limb length. On the approximation of fracture ends, the dynamized LRS was left for further 15-20 weeks and patient was mobilized with weight bearing to achieve union. Functional assessment was done by Association for the Study and Application of the Methods of Illizarov (ASAMI) criteria. Mean followup period was 15 months. The mean bone loss was 5.5 cm (range 4-9 cm). The mean duration of bone transport was 13 weeks (range 8-30 weeks) with a mean time for LRS in place was 44 weeks (range 24-51 weeks). The mean implant index was 56.4 days/cm. Mean union time was 52 weeks (range 31-60 weeks) with mean union index of 74.5 days/cm. Bony results as per the ASAMI scoring were excellent in 76% (19/25), good in 12% (3/25) and fair in 4% (1/25) with union in all except 2 patients, which showed poor results (8%) with only 2 patients having leg length discrepancy more than 2.5 cm. Functional results were excellent in 84% (21/25), good in 8% (2/25), fair in 8% (2/25). Pin tract infection was seen in 5 cases, out of which 4

  17. Bone stress in runners with tibial stress fracture.

    PubMed

    Meardon, Stacey A; Willson, John D; Gries, Samantha R; Kernozek, Thomas W; Derrick, Timothy R

    2015-11-01

    Combinations of smaller bone geometry and greater applied loads may contribute to tibial stress fracture. We examined tibial bone stress, accounting for geometry and applied loads, in runners with stress fracture. 23 runners with a history of tibial stress fracture & 23 matched controls ran over a force platform while 3-D kinematic and kinetic data were collected. An elliptical model of the distal 1/3 tibia cross section was used to estimate stress at 4 locations (anterior, posterior, medial and lateral). Inner and outer radii for the model were obtained from 2 planar x-ray images. Bone stress differences were assessed using two-factor ANOVA (α=0.05). Key contributors to observed stress differences between groups were examined using stepwise regression. Runners with tibial stress fracture experienced greater anterior tension and posterior compression at the distal tibia. Location, but not group, differences in shear stress were observed. Stepwise regression revealed that anterior-posterior outer diameter of the tibia and the sagittal plane bending moment explained >80% of the variance in anterior and posterior bone stress. Runners with tibial stress fracture displayed greater stress anteriorly and posteriorly at the distal tibia. Elevated tibial stress was associated with smaller bone geometry and greater bending moments about the medial-lateral axis of the tibia. Future research needs to identify key running mechanics associated with the sagittal plane bending moment at the distal tibia as well as to identify ways to improve bone geometry in runners in order to better guide preventative and rehabilitative efforts. Copyright © 2015 Elsevier Ltd. All rights reserved.

  18. Tibial stress fracture after computer-navigated total knee arthroplasty.

    PubMed

    Massai, F; Conteduca, F; Vadalà, A; Iorio, R; Basiglini, L; Ferretti, A

    2010-06-01

    A correct alignment of the tibial and femoral component is one of the most important factors determining favourable long-term results of a total knee arthroplasty (TKA). The accuracy provided by the use of the computer navigation systems has been widely described in the literature so that their use has become increasingly popular in recent years; however, unpredictable complications, such as displaced or stress femoral or tibial fractures, have been reported to occur a few weeks after the operation. We present a case of a stress tibial fracture that occurred after a TKA performed with the use of a computer navigation system. The stress fracture, which eventually healed without further complications, occurred at one of the pinhole sites used for the placement of the tibial trackers.

  19. Complications of short versus long cephalomedullary nail for intertrochanteric femur fractures, minimum 1 year follow-up.

    PubMed

    Vaughn, Josh; Cohen, Eric; Vopat, Bryan G; Kane, Patrick; Abbood, Emily; Born, Christopher

    2015-05-01

    Hip fractures are becoming increasingly common resulting in significant morbidity, mortality and raising healthcare costs. Both short and long cephalomedullary devices are currently employed to treat intertrochanteric hip fractures. However, which device is optimal continues to be debated as each implant has unique characteristics and theoretical advantages. This study looked to identify rates of complications associated with both long and short cephalomedullary nails for the treatment of intertrochanteric hip fractures. We retrospectively reviewed charts from 2006 to 2011, and we identified 256 patients were identified with AO class 31.1-32.3 fractures. Sixty were treated with short nails and 196 with long nails. Radiographs and charts were then analysed for failures and hardware complications. Catastrophic failure and hardware complication rates were not statistically different between short or long cephalomedullary nails. The overall catastrophic failure rate was 3.1 %; there was a 5 % failure rate in the short-nail group compared with a 2.6 % failure rate in the long-nail group (p = 0.191). There was a 3.33 % secondary femur fracture rate in the short-nail group, compared with none in the long-nail cohort (p = 0.054). The rate of proximal fixation failure was 1.67 % for the short-nail group and 2.0 % in the long-nail group (p = 0.406). Our data suggests equivocal outcomes as measured by similar catastrophic failure rate between both short and long cephalomedullary nails for intertrochanteric femur fractures. However, there was an increased risk of secondary femur fracture with short cephalomedullary nails when compared to long nails that approached statistical significance.

  20. Control of the micromovements of a composite-material nail design: A finite element analysis.

    PubMed

    Ben-Or, Mor; Shavit, Ronen; Ben-Tov, Tomer; Salai, Moshe; Steinberg, Ely L

    2016-02-01

    Intramedullary nail fixation is the most accepted modality for stabilizing long bone midshaft fractures. The commercially used nails are fabricated from Stainless Steel or Titanium. Composite-materials (CM) mainly carbon-fiber reinforced polymers (CFRP) have been gaining more interest and popularity due to their properties, such as modulus of elasticity close to that of bone, increased fatigue strength, and radio-opacity to irradiation that permits a better visualization of the healing process. The use of CFRP instead of metals allows better control of different directional movements along a fracture site. The purpose of this analysis was to design a CM intramedullary nail to enable micromovements as depicted on a finite element analysis method. We designed a three-dimentional femoral nail model. Three CFRP with different laminates arrangements, were included in the analysis. The finite element analysis involved applying vertical and horizontal loads on each of the designed and tested nails. The nails permitted a transverse micromovement of 0.75mm for the 45° lay-up and 1.5mm for the 90° lay-up for the CM, 1.38mm for the Titanium and 0.74mm for the Stainless Steel nails. The recorded axial movements were 0.53mm for the 45° lay-up, 0.87mm for the 90° lay-up, 0.46mm for the unsymmetrical lay-up CM, 0.046 for the Titanium and 0.02 for the Stainless Steel nails. Overall, the simulations showed that nail transverse micromovements can be reduced by using 45° carbon fiber orientations. Similar results were observed with each metal nails. We found that nail micromovements can be controlled by changing the directional stiffness using different lay-up orientations. These results can be useful for predicting nail micromovements under specified loading conditions which are crucial for stimulating callus formation in the early stages of healing. Copyright © 2015 Elsevier Ltd. All rights reserved.

  1. An electrochemical modeling of lithium-ion battery nail penetration

    NASA Astrophysics Data System (ADS)

    Chiu, Kuan-Cheng; Lin, Chi-Hao; Yeh, Sheng-Fa; Lin, Yu-Han; Chen, Kuo-Ching

    2014-04-01

    Nail penetration into a battery pack, resulting in a state of short-circuit and thus burning, is likely to occur in electric car collisions. To demonstrate the behavior of a specific battery when subject to such incidents, a standard nail penetration test is usually performed; however, conducting such an experiment is money consuming. The purpose of this study is to propose a numerical electrochemical model that can simulate the test accurately. This simulation makes two accurate predictions. First, we are able to model short-circuited lithium-ion batteries (LIBs) via electrochemical governing equations so that the mass and charge transfer effect could be considered. Second, the temperature variation of the cell during and after nail penetration is accurately predicted with the help of simulating the temperature distribution of thermal runaway cells by thermal abuse equations. According to this nail penetration model, both the onset of battery thermal runaway and the cell temperature profile of the test are obtained, both of which are well fitted with our experimental results.

  2. Habit tic nail deformity - a rare presentation in an 8 year old boy.

    PubMed

    El-Heis, S; Abadie, Al

    2016-11-15

    Habit tic nail deformity is a nail dystrophy resulting from habitual, repetitive trauma to the nail. It is usually acquired in adulthood, however, we report a case of habit tic nail deformity in an 8 year old boy. The diagnosis was made clinically with further history revealing that the boy repeatedly rubbed his thumbnails and pushed the cuticles. Emollient cream (Balneum®) was recommended twice daily and both the patient and his mother were educated on the behavioral nature of this condition. There was marked improvement at 6 months of treatment and further improvement at 12 months.We note that habit tic nail deformity is not exclusive to adults. Diagnosis can be made clinically. History and physical examination provide valuable clues and psychosocial links must be explored and addressed. Management is challenging and compliance with treatment is variable. Patient education, barrier methods, and behavioral therapy can be helpful in preventing further trauma to the nails.

  3. A cranial nail for fetal shunting.

    PubMed

    Saunders, R L; Simmons, G M; Edwards, W H; Crow, H C

    1985-01-01

    A small number of human fetal hydrocephalics have been treated by ventriculoamniotic shunts of silastic tubing. The Colorado device appears to be the one most commonly used. The original experimental device tested on a primate model resembled a hollow shingle nail. This was designed by Michedja and Hodgen, contained a spring valve, measured approximately 32 X 4 mm and was placed by hysterotomy. An attractive feature of this design was its fixation by impaction in the skull, preventing displacement by fetal activity, a reported disadvantage with the silastic devices. To our knowledge, no one has used this nail-like design and tailored it to transuterine percutaneous placement in a human case.

  4. Brittle Splitting Nails (Onychoschizia)

    MedlinePlus

    ... more common in women. Only very rarely are internal disease or vitamin deficiencies the reason (iron deficiency is the most common). One tip is that if the fingernails split, but the toenails are strong, then an external factor is the cause. Basically brittle nails can be ...

  5. Management of tibial non-unions according to a novel treatment algorithm.

    PubMed

    Ferreira, Nando; Marais, Leonard Charles

    2015-12-01

    Tibial non-unions represent a spectrum of conditions that are challenging to treat. The optimal management remains unclear despite the frequency with which these diagnoses are encountered. The aim of this study was to determine the outcome of tibial non-unions managed according to a novel tibial non-union treatment algorithm. One hundred and eighteen consecutive patients with 122 uninfected tibial non-unions were treated according to our proposed tibial non-union treatment algorithm. All patients were followed-up clinically and radiologically for a minimum of six months after external fixator removal. Four patients were excluded because they did not complete the intended treatment process. The final study population consisted of 94 men and 24 women with a mean age of 34 years. Sixty-seven non-unions were stiff hypertrophic, 32 mobile atrophic, 16 mobile oligotrophic and one true pseudoarthrosis. Six non-unions were classified as type B1 defect non-unions. Bony union was achieved after the initial surgery in 113/122 (92.6%) tibias. Nine patients had failure of treatment. Seven persistent non-unions were successfully retreated according to the tibial non-union treatment algorithm. This resulted in final bony union in 120/122 (98.3%) tibias. The proposed tibial non-union treatment algorithm appears to produce high union rates across a diverse group of tibial non-unions. Tibial non-unions however, remain difficult to treat and should be referred to specialist units where advanced reconstructive techniques are practiced on a regular basis. Copyright © 2015 Elsevier Ltd. All rights reserved.

  6. Nail Ridges: Cause for Concern?

    MedlinePlus

    ... of a health problem? Answers from Lawrence E. Gibson, M.D. It depends on the direction of ... indicate an underlying health condition. With Lawrence E. Gibson, M.D. Habif TP. Nail diseases. In: Clinical ...

  7. Revision Tibiotalocalcaneal Arthrodesis With a Pseudoelastic Intramedullary Nail.

    PubMed

    Latt, L Daniel; Smith, Kathryn Elizabeth; Dupont, Kenneth Michael

    2017-02-01

    Hindfoot (tibiotalocalcaneal or TTC) arthrodesis is commonly used to treat concomitant arthritis of the ankle and subtalar joints. Simultaneous fusion of both joints can be difficult to achieve especially in patients with impaired healing due to smoking, diabetes mellitus, or Charcot neuroarthropathy. Conventional intramedullary fixation devices allow for compression to be applied at the time of surgery, but this compression can be lost due to bone resorption or settling, leading to impaired healing. In contrast, the novel pseudoelastic intramedullary nail is designed to maintain compression at the arthrodesis sites throughout the healing process by the use of an internal pseudoelastic element. We present 2 cases of revision TTC arthrodesis using the pseudoelastic intramedullary nail. In the first case, an 80-year-old diabetic man with previous ankle and failed subtalar fusion with screws underwent revision TTC arthrodesis. In the second case, a 66-year-old man with Charcot neuroarthropathy and a failed TTC arthrodesis with a static intramedullary nail underwent revision tibiotalar arthrodesis. In both cases, computed tomography scan demonstrated successful union and patients were allowed full weight bearing by 3 months after surgery. These cases provide early evidence that sustained compression via an intramedullary nail can lead to rapid successful hindfoot fusion when standard approaches have failed. Therapeutic, Level IV: Case study.

  8. Enhanced econazole penetration into human nail by 2-n-nonyl-1,3-dioxolane.

    PubMed

    Hui, Xiaoying; Chan, Thomas C K; Barbadillo, Sherry; Lee, Christine; Maibach, Howard I; Wester, Ronald C

    2003-01-01

    This study determines the enhancing effects of 2-n-nonyl-1,3-dioxolane on the penetration of econazole, an antifungal drug, into the deeper layers of the human nail where fungal infection resides. Aliquots (10 microL) of Econail lacquer formulation containing 0.45 mg of [(14)C]-econazole with 18% 2-n-nonyl-1,3-dioxolane (test group) or without 2-n-nonyl-1,3-dioxolane (control group) were applied twice daily for 14 days to human nails that had been washed with ethanol before each morning's application. The hydration of the nail sample was well controlled to simulate normal physiological conditions. After 14 days of dosing, the inner ventral section of the nail plate was assayed for absorbed drug content, using a micrometer-controlled drilling and nail powder removal system. The mass balance values of [(14)C]-econazole in this study were 90.8 and 96.4% for the test and control groups, respectively. The weight-normalized econazole content in the ventral/intermediate nail plate center in the test group was 6-fold greater than that in the control (p = 0.008). The total econazole absorbed into the supporting bed cotton ball in the test group was nearly 200-fold greater than that in the control group (p = 0.008) over the 14-day period. The amount of econazole after dosing in the inner part of the human nail (potential diseased area) was 11.1 +/- 2.6 (SD) microg/mg of nail powder with 2-n-nonyl-1,3-dioxolane in the lacquer and 1.78 +/- 0.32 microg/mg without 2-n-nonyl-1,3-dioxolane (p = 0.008). The surface nail contained more econazole (p = 0.004), that is, nonabsorbed drug, where 2-n-nonyl-1,3-dioxolane was not part of the dosing solution. Econazole in the support bed under the nail (the total absorbed dose) was 47.5 +/- 22.0 mg in the lacquer with 2-n-nonyl-1,3-dioxolane and 0.2 +/- 0.1 mg in the lacquer without 2-n-nonyl-1,3-dioxolane (p = 0.008). Moreover the concentration in the deep nail layer in the test group is 14,000 times higher than minimum inhibitory

  9. Angle-stable and compressed angle-stable locking for tibiotalocalcaneal arthrodesis with retrograde intramedullary nails. Biomechanical evaluation.

    PubMed

    Mückley, Thomas; Hoffmeier, Konrad; Klos, Kajetan; Petrovitch, Alexander; von Oldenburg, Geert; Hofmann, Gunther O

    2008-03-01

    Retrograde intramedullary nailing is an established procedure for tibiotalocalcaneal arthrodesis. The goal of this study was to evaluate the effects of angle-stable locking or compressed angle-stable locking on the initial stability of the nails and on the behavior of the constructs under cyclic loading conditions. Tibiotalocalcaneal arthrodesis was performed in fifteen third-generation synthetic bones and twenty-four fresh-frozen cadaver legs with use of retrograde intramedullary nailing with three different locking modes: a Stryker nail with compressed angle-stable locking, a Stryker nail with angle-stable locking, and a statically locked Biomet nail. Analyses were performed of the initial stability of the specimens (range of motion) and the laxity of the constructs (neutral zone) in dorsiflexion/plantar flexion, varus/valgus, and external rotation/internal rotation. Cyclic testing up to 100,000 cycles was also performed. The range of motion and the neutral zone in dorsiflexion/plantar flexion at specific cycle increments were determined. In both bone models, the intramedullary nails with compressed angle-stable locking and those with angle-stable locking were significantly superior, in terms of a smaller range of motion and neutral zone, to the statically locked nails. The compressed angle-stable nails were superior to the angle-stable nails only in the synthetic bone model, in external/internal rotation. Cyclic testing showed the nails with angle-stable locking and those with compressed angle-stable locking to have greater stability in both models. In the synthetic bone model, compressed angle-stable locking was significantly better than angle-stable locking; in the cadaver bone model, there was no significant difference between these two locking modes. During cyclic testing, five statically locked nails in the cadaver bone model failed, whereas one nail with angle-stable locking and one with compressed angle-stable locking failed. Regardless of the bone model

  10. Gender differences in passive knee biomechanical properties in tibial rotation.

    PubMed

    Park, Hyung-Soon; Wilson, Nicole A; Zhang, Li-Qun

    2008-07-01

    The anterior cruciate ligament (ACL) is the most commonly injured knee ligament with the highest incidence of injury in female athletes who participate in pivoting sports. Noncontact ACL injuries commonly occur with both internal and external tibial rotation. ACL impingement against the lateral wall of the intercondylar notch during tibial external rotation and abduction has been proposed as an injury mechanism, but few studies have evaluated in vivo gender-specific differences in laxity and stiffness in external and internal tibial rotations. The purpose of this study was to evaluate these differences. The knees of 10 male and 10 female healthy subjects were rotated between internal and external tibial rotation with the knee at 60 degrees of flexion. Joint laxity, stiffness, and energy loss were compared between male and female subjects. Women had higher laxity (p = 0.01), lower stiffness (p = 0.038), and higher energy loss (p = 0.008) in external tibial rotation than did men. The results suggest that women may be at greater risk of ACL injury resulting from impingement against the lateral wall of the intercondylar notch, which has been shown to be associated with external tibial rotation and abduction.

  11. Does the Angle of the Nail Matter for Pertrochanteric Fracture Reduction? Matching Nail Angle and Native Neck-Shaft Angle.

    PubMed

    Parry, Joshua A; Barrett, Ian; Schoch, Bradley; Yuan, Brandon; Cass, Joseph; Cross, William

    2018-04-01

    To determine whether fixation of pertrochanteric hip fractures with cephalomedullary nails (CMNs) with a neck-shaft angle (NSA) less than the native NSA affects reduction and lag screw cutout. Retrospective comparative study. Level I trauma center. Patients treated with a CMN for unstable pertrochanteric femur fractures (OTA/AO 31-A2.2 and 31-A2.3) between 2005 and 2014. CMN fixation. NSA reduction and lag screw cutout. Patients fixed with a nail angle less than their native NSA were less likely to have good reductions [17% vs. 60%, 95% confidence interval (CI), -63% to -18%; P = 0.0005], secondary to more varus reductions (41% vs. 10%, 95% CI, 9%-46%; P = 0.01) and more fractures with ≥4 mm of displacement (63% vs. 35%, 95% CI, 3%-49%; P = 0.03). The cutout was not associated with the use of a nail angle less than the native NSA (60% vs. 76%, 95% CI, -56% to 18%; P = 0.5), varus reductions (60% vs. 32%, 95% CI, -13% to 62%; P = 0.3), or poor reductions (20% vs. 17%, 95% CI, -24% to 44%; P = 1.0). The fixation of unstable pertrochanteric hip fractures with a nail angle less than the native NSA was associated with more varus reductions and fracture displacement but did not affect the lag screw cutout. Therapeutic Level III. See Instructions for Authors for a complete description of levels of evidence.

  12. Modification of elastic stable intramedullary nailing with a 3rd nail in a femoral spiral fracture model - results of biomechanical testing and a prospective clinical study.

    PubMed

    Kaiser, Martin M; Stratmann, Christine; Zachert, Gregor; Schulze-Hessing, Maaike; Gros, Nina; Eggert, Rebecca; Rapp, Marion

    2014-01-08

    Elastic stable intramedullary nailing (ESIN) is the standard treatment for displaced diaphyseal femoral fractures in children. However, high complication rates (10-50%) are reported in complex fractures. This biomechanical study compares the stiffness with a 3rd nail implanted to that in the classical 2C-shaped configuration and presents the application into clinical practice. For each of the 3 configurations of ESIN-osteosynthesis with titanium nails eight composite femoral grafts (Sawbones®) with an identical spiral fracture were used: 2C configuration (2C-shaped nails, 2 × 3.5 mm), 3CM configuration (3rd nail from medial) and 3CL configuration (3rd nail from lateral). Each group underwent biomechanical testing in 4-point bending, internal/external rotation and axial compression. 2C and 3CM configurations showed no significant differences in this spiroid type fracture model. 3CL had a significantly higher stiffness during anterior-posterior bending, internal rotation and 9° compression than 2C, and was stiffer in the lateral-medial direction than 3CM. The 3CL was less stable during p-a bending and external rotation than both the others. As biomechanical testing showed a higher stability for the 3CL configuration in two (a-p corresponding to recurvation and 9° compression to shortening) of three directions associated with the most important clinical problems, we added a 3rd nail in ESIN-osteosynthesis for femoral fractures. 11 boys and 6 girls (2.5-15 years) were treated with modified ESIN of whom 12 were '3CL'; due to the individual character of the fractures 4 patients were treated with '3CM' (third nail from medial) and as an exception 1 adolescent with 4 nails and one boy with plate osteosynthesis. No additional stabilizations or re-operations were necessary. All patients achieved full points in the Harris-Score at follow-up; no limb length discrepancy occurred. The 3CL configuration provided a significantly higher stiffness than 2C and 3CM configurations

  13. Allergic contact dermatitis caused by (meth)acrylates in nail cosmetic products in users and nail technicians - a 5-year study.

    PubMed

    Raposo, Inês; Lobo, Inês; Amaro, Cristina; Lobo, Maria de Lurdes; Melo, Helena; Parente, Joana; Pereira, Teresa; Rocha, Joana; Cunha, Ana P; Baptista, Armando; Serrano, Pedro; Correia, Teresa; Travassos, Ana R; Dias, Margarida; Pereira, Fátima; Gonçalo, Margarida

    2017-12-01

    The increasing use of long-lasting nail aesthetic products has led to a growing number of cases of allergic contact dermatitis (ACD) caused by (meth)acrylates in recent years. To provide information on ACD caused by (meth)acrylates related to nail cosmetic products. We retrospectively reviewed files of patients with ACD caused by (meth)acrylates related to nail cosmetic products, who were patch tested between January 2011 and December 2015 in 13 departments of dermatology in Portugal. Two-hundred and thirty cases of ACD caused by (meth)acrylates (55 technicians, 56 consumers, and 119 with mixed exposure) had been documented, mostly as chronic hand eczema (93%). The most common sensitizers were: 2-hydroxyethyl methacrylate (HEMA), which was positive in 90% of the tested patients, 2-hydroxypropyl methacrylate (HPMA), which was positive in 64.1%, and ethyleneglycol dimethacrylate, which was positive in 54.5%. HEMA and HPMA were the most frequent positive allergens. HEMA, which identified 90% of cases, can be considered to be a good screening allergen. The high number of cases of ACD caused by (meth)acrylates in nail cosmetic products certainly warrants better preventive measures at the occupational level, and specific regulation in the field of consumer safety. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. New Polyurethane Nail Lacquers for the Delivery of Terbinafine: Formulation and Antifungal Activity Evaluation.

    PubMed

    Gregorí Valdes, Barbara S; Serro, Ana Paula; Gordo, Paulo M; Silva, Alexandra; Gonçalves, Lídia; Salgado, Ana; Marto, Joana; Baltazar, Diogo; Dos Santos, Rui Galhano; Bordado, João Moura; Ribeiro, Helena Margarida

    2017-06-01

    Onychomycosis is a fungal nail infection. The development of new topical antifungal agents for the treatment of onychomycosis has focused on formulation enhancements that optimize the pharmacological characteristics required for its effective treatment. Polyurethanes (PUs) have never been used in therapeutic nail lacquers. The aim of this work has been the development of new PU-based nail lacquers with antifungal activity containing 1.0% (wt/wt) of terbinafine hydrochloride. The biocompatibility, wettability, and the prediction of the free volume in the polymeric matrix were assessed using a human keratinocytes cell line, contact angle, and Positron Annihilation Lifetime Spectroscopy determinations, respectively. The morphology of the films obtained was confirmed by scanning electron microscopy, while the nail lacquers' bioadhesion to nails was determined by mechanical tests. Viscosity, in vitro release profiles, and antifungal activity were also assessed. This study demonstrated that PU-terbinafine-based nail lacquers have good keratinocyte compatibility, good wettability properties, and adequate free volume. They formed a homogenous film after application, with suitable adhesion to the nail plate. Furthermore, the antifungal test results demonstrated that the terbinafine released from the nail lacquer Formulation A PU 19 showed activity against dermatophytes, namely Trichophyton rubrum. Copyright © 2017 American Pharmacists Association®. Published by Elsevier Inc. All rights reserved.

  15. [The present study situation and application prospect of nail analysis for abused drugs].

    PubMed

    Chen, Hang; Xiang, Ping; Shen, Min

    2010-10-01

    In forensic toxicology analysis, various types of biological samples have their own special characteristics and scope of applications. In this article, the physiological structure of nails, methods for collecting and pre-processing samples, and for analyzing some poisons and drugs in the nails are reviewed with details. This paper introduces the influence factors of drug abuse of the nails. The prospects of its further applications are concluded based on the research results. Nails, as an unconventional bio-sample without general application, show great potential and advantages in forensic toxicology.

  16. Anatomic structures at risk: curved hindfoot arthrodesis nail--a cadaveric approach.

    PubMed

    Knight, Timothy; Rosenfeld, Peter; Jones, Ioan Tudur; Clark, Callum; Savva, Nick

    2014-01-01

    Retrograde intramedullary nailing of the hindfoot and ankle is an established procedure for salvage of severe foot and ankle deformity, arthritis, tumor, and instability. In the present study, retrograde hindfoot (tibiotalocalcaneal) arthrodesis nailing was performed using a standardized technique on 7 cadaver specimens by trained senior surgeons. The specimens were then dissected to determine the distance of the subcalcaneal structures at risk from the insertion point of the nail. The findings showed that the distance of the lateral neurovascular bundle from the edge of the nail was 6.5 (range 3.5 to 8, 95% confidence interval 5.9 to 7.1) mm. No neurovascular bundle was compromised, and all were within a previously described "safe window." Copyright © 2014 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  17. Creep behavior of soil nail walls in high plasticity index (PI) soils : technical report.

    DOT National Transportation Integrated Search

    2017-04-01

    An aspect of particular concern in the Geotechnical Engineering Circular No. 7: Soil Nail Walls (i.e., the soil : nail wall manual and construction guidelines) is the creep behavior of soil nail systems in high-plasticity : clays. This research proje...

  18. Extraction of the Wichita Fusion Nail after Knee Arthrodesis.

    PubMed

    Neuts, Ann-Sophie; Lammens, Johan; Stuyck, Jose

    2016-01-01

    To avoid a new exposition and partial damage of a knee arthrodesis site due to the removal of the Wichita fusion nail (WFN), a new extraction technique was developed, using a femoral osteotomy at the proximal end of the nail. Fixing the osteotomy with an Ilizarov frame offered the possibility to perform an additional correction of length and/or alignment if necessary.

  19. Permeation studies of novel terbinafine formulations containing hydrophobins through human nails in vitro.

    PubMed

    Vejnovic, Ivana; Huonder, Cornelia; Betz, Gabriele

    2010-09-15

    Existing treatments of onychomycosis are not satisfactory. Oral therapies have many side effects and topical formulations are not able to penetrate into the human nail plate and deliver therapeutical concentrations of active agent in situ. The purpose of the present study was to determine the amount of terbinafine, which permeates through the human nail plate, from liquid formulations containing enhancers, namely hydrophobins A-C in the concentration of 0.1% (w/v). The used reference solution contained 10% (w/v) of terbinafine in 60% (v/v) ethanol/water without enhancer. Permeability studies have been performed on cadaver nails using Franz diffusion cells modified to mount nail plates and filled with 60% (v/v) ethanol/water in the acceptor chamber. Terbinafine was quantitatively determined by HPLC. The amount of terbinafine remaining in the nail was extracted by 96% ethanol from pulverized nail material after permeation experiment and presented as percentage of the dry nail weight before the milling test. Permeability coefficient (PC) of terbinafine from reference solution was determined to be 1.52E-10 cm/s. Addition of hydrophobins improved PC in the range of 3E-10 to 2E-9 cm/s. Remaining terbinafine reservoir in the nail from reference solution was 0.83% (n=2). An increase of remaining terbinafine reservoir in the nail was observed in two out of three tested formulations containing hydrophobins compared to the reference. In all cases, known minimum inhibitory concentration of terbinafine for dermatophytes (0.003 microg/ml) has been exceeded in the acceptor chamber of the diffusion cells. All tested proteins (hydrophobins) facilitated terbinafine permeation after 10 days of permeation experiment, however one of them achieved an outstanding enhancement factor of 13.05 compared to the reference. Therefore, hydrophobins can be included in the list of potential enhancers for treatment of onychomycosis. Copyright 2010 Elsevier B.V. All rights reserved.

  20. Reliability, validity and feasibility of nail ultrasonography in psoriatic arthritis.

    PubMed

    Arbault, Anaïs; Devilliers, Hervé; Laroche, Davy; Cayot, Audrey; Vabres, Pierre; Maillefert, Jean-Francis; Ornetti, Paul

    2016-10-01

    To determine the feasibility, reliability and validity of nails ultrasonography in psoriatic arthritis as an outcome measure. Pilot prospective single-centre study of eight ultrasonography parameters in B mode and power Doppler concerning the distal interphalangeal (DIP) joint, the matrix, the bed and nail plate. Intra-observer and inter-observer reliability was evaluated for the seven quantitative parameters (ICC and kappa). Correlations between ultrasonography and clinical variables were searched to assess external validity. Feasibility was assessed by the time to carry out the examination and the percentage of missing data. Twenty-seven patients with psoriatic arthritis (age 55.0±16.2 years, disease duration 13.4±9.4 years) were included. Of these, 67% presented nail involvement on ultrasonography vs 37% on physical examination (P<0.05). Reliability was good (ICC and weighted kappa>0.75) for the seven quantitative parameters, except for synovitis of the DIP joint in B mode. The synovitis of the DIP joint revealed by ultrasonography correlated with the total number of clinical synovitis and Doppler US of the nail (matrix and bed). Doppler US of the matrix correlated with VAS pain but not with the ASDAS-CRP or with clinical enthesitis. No significant correlation was found with US nail thickness. The feasibility and reliability of ultrasonography of the nail in psoriatic arthritis appear to be satisfactory. Among the eight parameters evaluated, power Doppler of the matrix which correlated with local inflammation (DIP joint and bed) and with VAS pain could become an interesting outcome measure, provided that it is also sensitive to change. Copyright © 2015 Société française de rhumatologie. Published by Elsevier SAS. All rights reserved.

  1. The soleal line: a cause of tibial pseudoperiostitis.

    PubMed

    Levine, A H; Pais, M J; Berinson, H; Amenta, P S

    1976-04-01

    An unusually prominent soleal line (a normal anatomic variant) may mimic periosteal reaction along the posterior margin of the proximal tibial shaft. This area of pseudoperiostitis is differentiated from hyperostoses arising from the anterior tibial tubercle and the interosseous membrane. It is always associated with normal, undisturbed architecture of the underlying bone.

  2. A Biomechanical Assessment of Hand/Arm Force with Pneumatic Nail Gun Actuation Systems.

    PubMed

    Lowe, Brian D; Albers, James; Hudock, Stephen D

    2014-09-01

    A biomechanical model is presented, and combined with measurements of tip press force, to estimate total user hand force associated with two pneumatic nail gun trigger systems. The contact actuation trigger (CAT) can fire a nail when the user holds the trigger depressed first and then "bumps" the nail gun tip against the workpiece. With a full sequential actuation trigger (SAT) the user must press the tip against the workpiece prior to activating the trigger. The SAT is demonstrably safer in reducing traumatic injury risk, but increases the duration (and magnitude) of tip force exertion. Time integrated (cumulative) hand force was calculated for a single user from measurements of the tip contact force with the workpiece and transfer time between nails as inputs to a static model of the nail gun and workpiece in two nailing task orientations. The model shows the hand force dependence upon the orientation of the workpiece in addition to the trigger system. Based on standard time allowances from work measurement systems (i.e. Methods-Time Measurement - 1) it is proposed that efficient application of hand force with the SAT in maintaining tip contact can reduce force exertion attributable to the sequential actuation trigger to 2-8% (horizontal nailing) and 9-20% (vertical nailing) of the total hand/arm force. The present model is useful for considering differences in cumulative hand/arm force exposure between the SAT and CAT systems and may explain the appeal of the CAT trigger in reducing the user's perception of muscular effort.

  3. A Biomechanical Assessment of Hand/Arm Force with Pneumatic Nail Gun Actuation Systems

    PubMed Central

    Lowe, Brian D.; Albers, James; Hudock, Stephen D.

    2015-01-01

    A biomechanical model is presented, and combined with measurements of tip press force, to estimate total user hand force associated with two pneumatic nail gun trigger systems. The contact actuation trigger (CAT) can fire a nail when the user holds the trigger depressed first and then “bumps” the nail gun tip against the workpiece. With a full sequential actuation trigger (SAT) the user must press the tip against the workpiece prior to activating the trigger. The SAT is demonstrably safer in reducing traumatic injury risk, but increases the duration (and magnitude) of tip force exertion. Time integrated (cumulative) hand force was calculated for a single user from measurements of the tip contact force with the workpiece and transfer time between nails as inputs to a static model of the nail gun and workpiece in two nailing task orientations. The model shows the hand force dependence upon the orientation of the workpiece in addition to the trigger system. Based on standard time allowances from work measurement systems (i.e. Methods-Time Measurement - 1) it is proposed that efficient application of hand force with the SAT in maintaining tip contact can reduce force exertion attributable to the sequential actuation trigger to 2–8% (horizontal nailing) and 9–20% (vertical nailing) of the total hand/arm force. The present model is useful for considering differences in cumulative hand/arm force exposure between the SAT and CAT systems and may explain the appeal of the CAT trigger in reducing the user’s perception of muscular effort. PMID:26321780

  4. Health hazard evaluation report HETA 90-048-2253, Haute Nails, Norman, Oklahoma

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Almaguer, D.; Blade, L.M.

    In response to a request from the owner/operator of the Haute Nails Salon, Norman, Oklahoma, an evaluation was undertaken of possible chemical exposures from the use of nail sculpturing products. Haute Nails was an artificial nail sculpturing and tanning salon employing two full time nail sculpturers and four part time receptionists. The company was located on the first floor of a two story brick building. Long term general area air sampling was conducted for volatile organic chemicals, formaldehyde, and methacrylates; personal breathing zone air sampling was conducted for methacrylates. Ethyl-methacrylate concentrations in long term samples ranged from 10.3 to 14.1more » mg/cu m. Breathing zone concentrations of ethyl-methacrylate were 128 mg/cu m for a 7 minute sample and 78.9 mg/cu m for a 14 minute sample during nail sculpturing. Carbon-dioxide measurements exceeded the recommended level of 1000 parts per million. The authors conclude that there were no overexposures to ethyl-methylacrylate during the evaluation. The heating and air conditioning system did not provide for the mechanical exchange of outside air and no exhaust fans were located in the area served by the system. The authors recommend that an outside air supply duct be added to the present system.« less

  5. [Results of femoral lengthening over an intramedullary nail and external fixator].

    PubMed

    Jasiewicz, Barbara; Kacki, Wojciech; Tesiorowski, Maciej; Potaczek, Tomasz

    2008-01-01

    Current techniques of operative limb lengthening usually are based on distraction osteogenesis. One of the techniques is limb lengthening over an intramedullary nail. The goal of this study is to evaluate the results of femoral lengthening over an intramedullary nail. Between 1999 and 200619 femoral "over nail" lengthenings were performed. There were 7 males and 12 females. Mean patients' age at surgery was 15.8 years, and mean initial femoral shortening was 5.1 cm. Operative technique consisted of one-stage implantation of intramedullary nail and external fixator. Ilizarov apparatus was used in 9 patients, monolateral fixator in 10 cases--ORTHOFIX in 9 patients, Wagner fixator--in 1 patient. Intramedullary nail was locked proximally with screws or Schanz pins from external fixator. After distraction phase, external fixator was removed and distal locking screws were applied. Evaluation criteria: obtained lengthening, time of external fixator, treatment time, healing index, external fixation index, range of motion in hip and knee joints and complications according to Paley. The mean lengthening was 4.6 cm, and mean distraction time was 66.6 days. Mean time of external fixation was 115.5 days, and external fixation index was 26.2 days for centimeter. Healing index was 36.9 days for centimeter. In cases with monolateral fixator, healing index did not differ with the whole group. During treatment 18 complications occurred, for a rate of 0.9 complication per segment. Lengthening over an intramedullary nail reduces the time of external fixator. Over nail femoral lengthening can prevent axis deviation following regenerate bending. Complication rate is similar to lengthenings with the classic Ilizarov technique. There are no differences in the treatment time in relation to the type of external fixator.

  6. Effects of reinforcement without extinction on increasing compliance with nail cutting: A systematic replication.

    PubMed

    Dowdy, Art; Tincani, Matt; Nipe, Timothy; Weiss, Mary Jane

    2018-06-17

    Personal hygiene routines, such as nail cutting, are essential for maintaining good health. However, individuals with autism spectrum disorder (ASD) and other developmental disabilities often struggle to comply with essential, personal hygiene routines. We conducted a systematic replication of Schumacher and Rapp (2011), Shabani and Fisher (2006), and Bishop et al. (2013) to evaluate an intervention that did not require escape extinction for increasing compliance with nail cutting. With two adolescents diagnosed with ASD who resisted nail cutting, we evaluated the effects of delivering a preferred edible item contingent on compliance with nail cutting. Results indicated that the treatment reduced participants' escape responses and increased their compliance with nail cutting. © 2018 Society for the Experimental Analysis of Behavior.

  7. [Electromagnetic navigation interlocking intramedullary nail technology for treatment of femoral shaft fractures].

    PubMed

    Zuo, Kangkang; Qin, Wei; Guo, Qing; Palati-Ababaikeli; Qiao, Peiliu; Shen, Mingquan; Yin, Lele; Pan, Qilin; Xu, Xiaoxiong

    2014-10-01

    To explore the value of electromagnetic navigation interlocking intramedullary nail in the treatment of femoral shaft fracture. Between July 2012 and October 2013, 53 cases of femoral shaft fracture were treated. There were 40 males and 13 females, aged 16-52 years (mean, 38.3 years). The causes of injury were traffic accident in 28 cases, falling from height in 11 cases, falling in 7 cases, crush injury in 4 cases, and other in 3 cases. Of 53 cases, there were 3 cases of open fracture (Gustilo I degree) and 50 cases of closed fracture. Fracture was located in the proximal femur in 17 cases, middle femur in 29 cases, and distal femur in 7 cases. According to Winquist classification, 7 cases were rated as type I, 8 cases as type II, 22 cases as type III, and 16 cases as type IV; according to AO classification, 18 cases were rated as type 32-A, 28 cases as type 32-B, and 7 cases as type 32-C. The time from injury to operation was 3-11 days (mean, 5 days). Distal interlocking intramedullary nail was implanted using electromagnetic navigation. The distal locking nail operation with interlocking intramedullary nail was successfully completed under electromagnetic navigation; the one-time success rate of distal locking nail operation reached 100%; and the locking nail time was 5.0-9.5 minutes (mean, 7.0 minutes). Healing of incision by first intention was obtained after operation, and no complication of skin necrosis, infection, and sinus tract occurred. Fifty-three cases were all followed up 5-12 months (mean, 9 months). One case had hip pain and weaken middle gluteal muscle strength, and the symptoms disappeared after removing the nail. During the follow-up period, no broken nails, nail exit, infection, or re-fracture occurred. All fractures achieved clinical healing, and the healing time was 8-22 weeks (mean, 14.5 weeks). In 49 patients followed up 8 months, the Lysholm score was excellent in 44 cases, good in 4 cases, and acceptable in 1 case, with an excellent and

  8. Refractures of the paediatric forearm with the intramedullary nail in situ.

    PubMed

    van Egmond, Pim W; van der Sluijs, Hans A; van Royen, Barend J; Saouti, Rachid

    2013-09-24

    Forearm fractures in children are common. When conservative treatment fails, internal fixation with Elastic Stable Intramedullary Nailing (ESIN) become the first choice in the operative treatment of diaphyseal forearm shaft fractures. Refractures with the intramedullary nail in situ are known to occur but formal guidelines to guide management in such fractures are lacking. We present a well-documented case of a radius midshaft refracture in a 12-year-old boy with the intramedullary nail in situ, managed by closed reduction. Literature is reviewed for this type of complication, the treatment of 30 similar cases is discussed and a treatment strategy is defined. The refracture of the paediatric forearm fracture with the intramedullary nail in situ is a rare, but probably under recognised complication which is observed in approximately 2.3% of the study population. Closed reduction may be considered in these cases.

  9. Extraction of the Wichita Fusion Nail after Knee Arthrodesis

    PubMed Central

    Neuts, Ann-Sophie; Lammens, Johan; Stuyck, Jose

    2016-01-01

    To avoid a new exposition and partial damage of a knee arthrodesis site due to the removal of the Wichita fusion nail (WFN), a new extraction technique was developed, using a femoral osteotomy at the proximal end of the nail. Fixing the osteotomy with an Ilizarov frame offered the possibility to perform an additional correction of length and/or alignment if necessary. PMID:28529847

  10. Patterns of clinical nail appearances in patients with cutaneous psoriasis

    PubMed Central

    MARINA, ELENA MIHAELA; BOTAR-JID, CAROLINA; BOLBOACA, SORANA DANIELA; ROMAN, IULIA IOANA; SENILA, CORINA SIMONA; MIHU, CARMEN MIHAELA; TATARU, DUMITRU ALEXANDRU

    2017-01-01

    Background and aim Nail manifestations are often an overlooked aspect in psoriatic disease, cutaneous and joint involvement being far more often reported and investigated. The reported prevalence of nail changes varies in literature, specific fingernail clinical features having different degrees of occurrence. The aim of this study was to describe specific clinical patterns of fingernail alterations in adult patients with plaque-type psoriasis in a university hospital in the North-West of Romania. Methods Clinical data of 35 patients with fingernail psoriasis were collected and analyzed. Psoriasis Area and Severity Index (PASI) and Nail Psoriasis Severity Index (NAPSI) scores were used to quantify disease extension in each patient. Results PASI score proved linearly correlated with NAPSI score (p<0.05). The age of onset of fingernail psoriasis was positively correlated with age of onset cutaneous psoriasis (p<0.0001). Furthermore, the duration of cutaneous involvement and NAPSI proved significantly related (p<0.05). The third fingernail in the right hand and first fingernail in the left hand were in most of the cases severely affected. The most common observed nail pattern was pitting, followed by salmon patches and subungual hyperkeratosis. Conclusion Important nail changes appear even in moderate forms of cutaneous psoriasis. Particular localization of specific fingernail psoriasis pattern enables the possibility of detecting early stage disease. PMID:28246493

  11. Tibial component considerations in bicruciate-retaining total knee arthroplasty: A 3D MRI evaluation of proximal tibial anatomy.

    PubMed

    Saxena, Vishal; Anari, Jason B; Ruutiainen, Alexander T; Voleti, Pramod B; Stephenson, Jason W; Lee, Gwo-Chin

    2016-08-01

    Restoration of normal anatomy and proper ligament balance are theoretical prerequisites for reproducing physiological kinematics with bicruciate-retaining total knee arthroplasty (TKA). The purpose of this study was to use a 3D MRI technique to evaluate the topography of the proximal tibia and outline considerations in tibial component design for bicruciate-retaining TKA. We identified 100 consecutive patients (50 males and 50 females) between ages 20 and 40 years with knee MRIs without arthritis, dysplasia, ACL tears, or prior knee surgery. A novel 3D MRI protocol coordinating axial, coronal, and sagittal images was used to measure: 1) medial and lateral posterior tibial slopes; 2) medial and lateral coronal slopes; and 3) distance from the anterior tibia to the ACL footprint. There was no overall difference in medial and lateral posterior tibial slopes (5.5° (95% CI 5.0 to 6.0°) vs. 5.4° (95% CI 4.8 to 6.0°), respectively (p=0.80)), but 41 patients had side-to-side differences greater than 3°. The medial coronal slope was greater than the lateral coronal slope (4.6° (95% CI 4.0 to 5.1°) vs. 3.3° (95% CI 2.9 to 3.7°), respectively (p<0.0001)). Females had less clearance between the anterior tibia and ACL footprint than males (10.8mm (95% CI 10.4 to 11.2mm) vs. 13.0mm (95% CI 12.5 to 13.5mm), respectively (p<0.0001)). Due to highly variable proximal tibial topography, a monoblock bicruciate-retaining tibial baseplate may not reproduce normal anatomy in all patients. Level IV - Anatomic research study. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Nail care feature gets to the heart of core nursing skills.

    PubMed

    Lindsay, Margot

    2009-07-07

    Thank you for drawing attention to the importance of personal hygiene in nail care (art&science June 17). Authors Bridget Malkin and Pat Berridge discuss the subject in depth and address the confusion over who should perform nail care for patients.

  13. Importance of tibial slope for stability of the posterior cruciate ligament deficient knee.

    PubMed

    Giffin, J Robert; Stabile, Kathryne J; Zantop, Thore; Vogrin, Tracy M; Woo, Savio L-Y; Harner, Christopher D

    2007-09-01

    Previous studies have shown that increasing tibial slope can shift the resting position of the tibia anteriorly. As a result, sagittal osteotomies that alter slope have recently been proposed for treatment of posterior cruciate ligament (PCL) injuries. Increasing tibial slope with an osteotomy shifts the resting position anteriorly in a PCL-deficient knee, thereby partially reducing the posterior tibial "sag" associated with PCL injury. This shift in resting position from the increased slope causes a decrease in posterior tibial translation compared with the PCL-deficient knee in response to posterior tibial and axial compressive loads. Controlled laboratory study. Three knee conditions were tested with a robotic universal force-moment sensor testing system: intact, PCL-deficient, and PCL-deficient with increased tibial slope. Tibial slope was increased via a 5-mm anterior opening wedge osteotomy. Three external loading conditions were applied to each knee condition at 0 degrees, 30 degrees, 60 degrees, 90 degrees, and 120 degrees of knee flexion: (1) 134-N anterior-posterior (A-P) tibial load, (2) 200-N axial compressive load, and (3) combined 134-N A-P and 200-N axial loads. For each loading condition, kinematics of the intact knee were recorded for the remaining 5 degrees of freedom (ie, A-P, medial-lateral, and proximal-distal translations, internal-external and varus-valgus rotations). Posterior cruciate ligament deficiency resulted in a posterior shift of the tibial resting position to 8.4 +/- 2.6 mm at 90 degrees compared with the intact knee. After osteotomy, tibial slope increased from 9.2 degrees +/- 1.0 degrees in the intact knee to 13.8 degrees +/- 0.9 degrees. This increase in slope reduced the posterior sag of the PCL-deficient knee, shifting the resting position anteriorly to 4.0 +/- 2.0 mm at 90 degrees. Under a 200-N axial compressive load with the osteotomy, an additional increase in anterior tibial translation to 2.7 +/- 1.7 mm at 30 degrees was

  14. The Chinese Nail Murders: forensic medicine in Imperial China.

    PubMed Central

    Summers, W. C.

    1999-01-01

    Robert van Gulik was a respected Dutch sinologist and author who first translated a collection of traditional Chinese detective stories into English and then created additional fictional stories based on the same characters and setting in the Tang dynasty. One of these stories, The Chinese Nail Murders, draws on van Gulik's professional interest in law and his knowledge of early Chinese works on forensic medicine. This novel develops a common theme in Chinese detective fiction, murder by a nail wound to the head. The difficulty in detection of this mode of violence posed a particular problem for the examining magistrate because postmortem examination was mostly limited to external observations. This essay compares the development of Chinese and Western forensic medicine in the context of the nail murder motif. PMID:11138936

  15. Tibial Bowing and Pseudarthrosis in Neurofibromatosis Type 1

    DTIC Science & Technology

    2014-04-01

    Neurofibromatosis Type 1 PRINCIPAL INVESTIGATOR: Dr. David Stevenson CONTRACTING ORGANIZATION: University of Utah SALT LAKE CITY...COVERED 1 April 2013 - 31 March 2014 4. TITLE AND SUBTITLE Tibial Bowing and Pseudarthrosis in Neurofibromatosis Type 1 5a. CONTRACT NUMBER...SUPPLEMENTARY NOTES 14. ABSTRACT Anterolateral tibial bowing is a morbid skeletal manifestation observed in 5% of children with neurofibromatosis

  16. Application research of 3D additive manufacturing technology in the nail shell

    NASA Astrophysics Data System (ADS)

    Xiao, Shanhua; Yan, Ruiqiang; Song, Ning

    2018-04-01

    Based on the analysis of hierarchical slicing algorithm, 3D scanning of enterprise product nailing handle case file is carried out, point cloud data processing is performed on the source file, and the surface modeling and innovative design of nail handling handle case are completed. Using MakerBot Replicator2X-based 3D printer for layered 3D print samples, for the new nail product development to provide reverse modeling and rapid prototyping technical support.

  17. Comparison of volumetric bone mineral density in the tibial region of interest for ACL reconstruction.

    PubMed

    Klein, Scott A; Nyland, John; Caborn, David N M; Kocabey, Yavuz; Nawab, Akbar

    2005-12-01

    Adequate tibial bone mineral density (BMD) is essential to soft tissue graft fixation during anterior cruciate ligament (ACL) reconstruction. The purpose of this study was to compare volumetric bone plug density measurements at the tibial region of interest for ACL reconstruction using a standardized immersion technique and Archimedes' principle. Cancellous bone cores were harvested from the proximal, middle, and distal metaphyseal regions of the lateral tibia and from the standard tibial tunnel location used for ACL reconstruction of 18 cadaveric specimens. Proximal tibial cores displayed 32.6% greater BMD than middle tibial cores and 31.8% greater BMD than distal tibial cores, but did not differ from the BMD of the tibial tunnel cores. Correlational analysis confirmed that the cancellous BMD in the tibial tunnel related to the cancellous BMD of the proximal and distal lateral tibial metaphysis. In conjunction with its adjacent cortical bone, the cancellous BMD of the region used for standard tibial tunnel placement provides an effective foundation for ACL graft fixation. In tibia with poor BMD, bicortical fixation that incorporates cortical bone from the distal tibial tunnel region is recommended.

  18. Cranial tibial thrust: a primary force in the canine stifle.

    PubMed

    Slocum, B; Devine, T

    1983-08-15

    A cranially directed force identified within the canine stifle joint was termed cranial tibial thrust. It was generated during weight bearing by tibial compression, of which the tarsal tendon of the biceps femoris is a major contributor, and by the slope of the tibial plateau, found to have a mean cranially directed inclination of 22.6 degrees. This force may be an important factor in cranial cruciate ligament rupture and in generation of cranial drawer sign.

  19. Habit Reversal versus Object Manipulation Training for Treating Nail Biting: A Randomized Controlled Clinical Trial

    PubMed Central

    Ghanizadeh, Ahmad; Bazrafshan, Amir; Dehbozorgi, Gholamreza

    2013-01-01

    Objective This is a parallel, three group, randomized, controlled clinical trial, with outcomes evaluated up to three months after randomization for children and adolescents with chronic nail biting. The current study investigates the efficacy of habit reversal training (HRT) and compares its effect with object manipulation training (OMT) considering the limitations of the current literature. Method Ninety one children and adolescents with nail biting were randomly allocated to one of the three groups. The three groups were HRT (n = 30), OMT (n = 30), and wait-list or control group (n = 31). The mean length of nail was considered as the main outcome. Results The mean length of the nails after one month in HRT and OMT groups increased compared to the waiting list group (P < 0.001, P < 0.001, respectively). In long term, both OMT and HRT increased the mean length of nails (P < 0.01), but HRT was more effective than OMT (P < 0.021). The parent-reported frequency of nail biting did show similar results as to the mean length of nails assessment in long term. The number of children who completely stopped nail biting in HRT and OMT groups during three months was 8 and 7, respectively. This number was zero during one month for the wait-list group. Conclusion This trial showed that HRT is more effective than wait-list and OMT in increasing the mean length of nails of children and adolescents in long terms. PMID:24130603

  20. Tibial component coverage based on bone mineral density of the cut tibial surface during unicompartmental knee arthroplasty: clinical relevance of the prevention of tibial component subsidence.

    PubMed

    Lee, Yong Seuk; Yun, Ji Young; Lee, Beom Koo

    2014-01-01

    An optimally implanted tibial component during unicompartmental knee arthroplasty would be flush with all edges of the cut tibial surface. However, this is often not possible, partly because the tibial component may not be an ideal shape or because the ideal component size may not be available. In such situations, surgeons need to decide between component overhang and underhang and as to which sites must be covered and which sites could be undercovered. The objectives of this study were to evaluate the bone mineral density of the cut surface of the proximal tibia around the cortical rim and to compare the bone mineral density according to the inclusion of the cortex and the site-specific matched evaluation. One hundred and fifty consecutive patients (100 men and 50 women) were enrolled in this study. A quantitative computed tomography was used to determine the bone density of the cut tibial surface. Medial and lateral compartments were divided into anterior, middle, and posterior regions, and these three regions were further subdivided into two regions according to containment of cortex. The site-specific matched comparison (medial vs. lateral) of bone mineral density was performed. In medial sides, the mid-region, including the cortex, showed the highest bone mineral density in male and female patients. The posterior region showed the lowest bone mineral density in male patients, and the anterior and posterior regions showed the lowest bone mineral density in female patients. Regions including cortex showed higher bone mineral density than pure cancellous regions in medial sides. In lateral sides, posterior regions including cortex showed highest bone mineral density with statistical significance in both male and female patients. The anterior region showed the lowest bone mineral density in both male and female patients. The mid-region of the medial side and the posterior region of the lateral side are relatively safe without cortical coverage when the component

  1. The SIGN nail for knee fusion: technique and clinical results

    PubMed Central

    Anderson, Duane Ray; Anderson, Lucas Aaron; Haller, Justin M.; Feyissa, Abebe Chala

    2016-01-01

    Purpose: Evaluate the efficacy of using the SIGN nail for instrumented knee fusion. Methods: Six consecutive patients (seven knees, three males) with an average age of 30.5 years (range, 18–50 years) underwent a knee arthrodesis with SIGN nail (mean follow-up 10.7 months; range, 8–14 months). Diagnoses included tuberculosis (two knees), congenital knee dislocation in two knees (one patient), bacterial septic arthritis (one knee), malunited spontaneous fusion (one knee), and severe gout with 90° flexion contracture (one knee). The nail was inserted through an anteromedial entry point on the femur and full weightbearing was permitted immediately. Results: All knees had clinical and radiographic evidence of fusion at final follow-up and none required further surgery. Four of six patients ambulated without assistive device, and all patients reported improved overall physical function. There were no post-operative complications. Conclusion: The technique described utilizing the SIGN nail is both safe and effective for knee arthrodesis and useful for austere environments with limited fluoroscopy and implant options. PMID:27163095

  2. The SIGN nail for knee fusion: technique and clinical results.

    PubMed

    Anderson, Duane Ray; Anderson, Lucas Aaron; Haller, Justin M; Feyissa, Abebe Chala

    2016-02-05

    Evaluate the efficacy of using the SIGN nail for instrumented knee fusion. Six consecutive patients (seven knees, three males) with an average age of 30.5 years (range, 18-50 years) underwent a knee arthrodesis with SIGN nail (mean follow-up 10.7 months; range, 8-14 months). Diagnoses included tuberculosis (two knees), congenital knee dislocation in two knees (one patient), bacterial septic arthritis (one knee), malunited spontaneous fusion (one knee), and severe gout with 90° flexion contracture (one knee). The nail was inserted through an anteromedial entry point on the femur and full weightbearing was permitted immediately. All knees had clinical and radiographic evidence of fusion at final follow-up and none required further surgery. Four of six patients ambulated without assistive device, and all patients reported improved overall physical function. There were no post-operative complications. The technique described utilizing the SIGN nail is both safe and effective for knee arthrodesis and useful for austere environments with limited fluoroscopy and implant options.

  3. Knee arthrodesis using an intramedullary nail.

    PubMed

    Crockarell, John R; Mihalko, Marc J

    2005-09-01

    Fifteen knee arthrodeses using an intramedullary nail were performed in 15 patients. Indications included 11 failed total knee arthroplasties (10 of 11 septic). A retrospective review revealed 100% fusion rate. Complications included 4 cases of painful hardware, 1 trochanteric bursitis, and 1 deep infection. Ten patients were available for assessment at 7 years follow-up. Average leg length discrepancy was 3.7 cm. Anatomic axis averaged 1.3 degrees valgus. Flexion angle averaged 3.5 degrees . Compared with age-matched controls, our patients fared significantly worse in physical functioning, physical role, bodily pain, vitality, and social functioning. Arthrodesis of the knee with an intramedullary nail provides a reliable means of fusion with reasonable alignment. These patients have high rates of pain and diminished functional status.

  4. Modelling the strength of an aluminium-steel nailed joint

    NASA Astrophysics Data System (ADS)

    Goldspiegel, Fabien; Mocellin, Katia; Michel, Philippe

    2018-05-01

    For multi-material applications in automotive industry, a cast aluminium (upper layer) and dual-phase steel (lower layer) superposition joined with High-Speed Nailing process is investigated through an experimental vs numerical framework. Using FORGE® finite-element software, results from joining simulations have been inserted into models in charge of nailed-joint mechanical testings. Numerical Shear and Cross-tensile tests are compared to experimental ones to discuss discrepancy and possible improvements.

  5. Congenital yellow nail syndrome: a case report and its relationship to nonimmune fetal hydrops.

    PubMed

    Nanda, Arti; Al-Essa, Fahad H; El-Shafei, Wael M; Alsaleh, Qasem A

    2010-01-01

    Yellow nail syndrome (YNS) is an uncommon disorder characterized by a triad of nail dystrophy, lymphedema, and pleural effusion. It is rare in children and congenital occurrence of YNS has been very rarely described. We report a 2-year-old Arab boy having congenital yellow nail syndrome with mild facial dysmorphism and bilateral conjunctival pigmentation born to consanguineous parents. One of his older siblings had died of nonimmune fetal hydrops (NIFH). The case supports the genetic basis of yellow nail syndrome with a possible relationship to nonimmune fetal hydrops. © 2010 Wiley Periodicals, Inc.

  6. 76 FR 19124 - Certain Steel Nails From the United Arab Emirates

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-06

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1185 (Preliminary)] Certain Steel Nails From the United Arab Emirates AGENCY: United States International Trade Commission. ACTION: Institution... certain steel nails, provided for in subheadings 7317.00.55, 7317.00.65 and 7317.00.75 of the Harmonized...

  7. 77 FR 27421 - Certain Steel Nails From the United Arab Emirates: Amended Final Determination of Sales at Less...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-10

    ... limited to, nails made of round wire and nails that are cut. Certain steel nails may be of one piece construction or constructed of two or more pieces. Certain steel nails may be produced from any type of steel... following products: Non-collated (i.e., hand-drive or bulk), two-piece steel nails having plastic or steel...

  8. The efficacy of single-stage open intramedullary nailing of neglected femur fractures.

    PubMed

    Boopalan, P R J V C; Sait, Azad; Jepegnanam, Thilak Samuel; Matthai, Thomas; Varghese, Viju Daniel

    2014-02-01

    Neglected femur fractures are not rare in the developing world. Treatment options include single-stage open reduction and intramedullary nailing, or open release, skeletal traction, and then second-stage open intramedullary nailing, with bone grafting. Single-stage procedures have the potential advantage of avoiding neurovascular complications secondary to acute lengthening, but they require a second operation, with potentially increased resource use and infection risk. We sought to determine the (1) likelihood of union, (2) complications and reoperations, and (3) functional results with single-stage open intramedullary nailing without bone grafting in patients with neglected femur fractures. Between January 2003 and December 2007, 17 consecutive patients presented to our practice with neglected femoral shaft fractures. All were treated with single-stage nailing without bone grafting. There were 15 men and two women with a median age of 27 years. The average time from fracture to treatment was 13 weeks (range, 4-44 weeks). Eleven patients underwent open nailing with interlocked nails and six were treated with cloverleaf Kuntscher nails. Patients were followed for a minimum of 6 months (mean, 33 months; range, 6-72 months). The mean preoperative ROM of the knee was 28° (range, 10°-150°) and femoral length discrepancy was 3.1 cm (range, 1-5 cm). All fractures united and the mean time to union was 16 weeks (range, 7-32 weeks). There were no neurologic complications secondary to acute lengthening. The mean postoperative ROM of the knee was 130° (range, 60°-150°). All patients were able to return to preinjury work. Sixteen patients regained their original femoral length. One-stage open intramedullary nailing of neglected femoral diaphyseal fractures without bone grafting was safe and effective, and obviated the need for a two-stage approach. Although the findings need to be replicated in larger numbers of patients, we believe this technique may be useful in

  9. Biomechanical comparison of blade plate and intramedullary nail fixation for tibiocalcaneal arthrodesis.

    PubMed

    Lee, Arthur T; Sundberg, Eric B; Lindsey, Derek P; Harris, Alex H S; Chou, Loretta B

    2010-02-01

    Tibiocalcaneal arthrodesis is an uncommon salvage procedure used for complex problems of the ankle and hindfoot. A biomechanical evaluation of the fixation constructs of this procedure has not been studied previously. The purpose of this study was to compare intramedullary nail to blade plate fixation in a deformity model in fatigue endurance testing and load to failure. Nine matched pairs of fresh frozen cadaveric legs underwent talectomy followed by fixation with a blade plate and 6.5-mm fully threaded cancellous screw or an ankle arthrodesis intramedullary nail. The specimens were loaded to 270 N at a rate of 3 Hz for a total of 250,000 cycles, followed by loading to failure. Intramedullary nail fixation demonstrated greater mean stiffness throughout the fatigue endurance testing, from cycles 10 through 250,000 (blade plate versus intramedullary nail; cycle 10, 93 +/- 34 N/mm versus 117 +/- 40 N/mm (t = 2.33, p = 0.04); cycle 100, 89 +/- 34 N/mm versus 118 +/- 42 N/mm (t = 3.16, p = 0.01); cycle 1000, 86 +/- 32 N/mm versus 120 +/- 45 N/mm (t = 3.52, p = 0.01); cycle 10,000, 83 +/- 36 N/mm versus 128 +/- 50 N/mm (t = 3.80, p = 0.01); cycle 100,000, 82 +/- 34 N/mm versus 126 +/- 52 N/mm (t = 3.70, p = 0.01); cycle 250,000, 80 +/- 31 N/mm versus 125 +/- 49 N/mm (t = 4.2, p = 0.003). There was no statistically significant difference between the intramedullary nail and blade plate fixation in cycle one or in load to failure; cycle 10, blade plate 70 +/- 38 N/mm and intramedullary nail 67 +/- 20 N/mm (t = 0.60, p = 0.56); load to failure, blade plate 808 +/- 193 N, IMN 1074 +/- 290 N) (p = 0.15). Intramedullary nail fixation was biomechanically superior to blade plate and screw fixation in a tibiocalcaneal arthrodesis construct. The ankle arthrodesis intramedullary nail provides greater stiffness for fixation in tibiocalcaneal arthrodesis, which may improve healing.

  10. Total knee arthroplasty and fractures of the tibial plateau

    PubMed Central

    Softness, Kenneth A; Murray, Ryan S; Evans, Brian G

    2017-01-01

    Tibial plateau fractures are common injuries that occur in a bimodal age distribution. While there are various treatment options for displaced tibial plateau fractures, the standard of care is open reduction and internal fixation (ORIF). In physiologically young patients with higher demand and better bone quality, ORIF is the preferred method of treating these fractures. However, future total knee arthroplasty (TKA) is a consideration in these patients as post-traumatic osteoarthritis is a common long-term complication of tibial plateau fractures. In older, lower demand patients, ORIF is potentially less favorable for a variety of reasons, namely fixation failure and the need for delayed weight bearing. In some of these patients, TKA can be considered as primary mode of treatment. This paper will review the literature surrounding TKA as both primary treatment and as a salvage measure in patients with fractures of the tibial plateau. The outcomes, complications, techniques and surgical challenges are also discussed. PMID:28251061

  11. External lead contamination of women's nails by surma in Pakistan: Is the biomarker reliable?

    PubMed

    Ikegami, Akihiko; Takagi, Mai; Fatmi, Zafar; Kobayashi, Yayoi; Ohtsu, Mayumi; Cui, Xiaoyi; Mise, Nathan; Mizuno, Atsuko; Sahito, Ambreen; Khoso, Aneeta; Kayama, Fujio

    2016-11-01

    Adverse health effects of heavy metals are a public health concern, especially lead may cause negative health impacts to human fetal and infantile development. The lead concentrations in Pakistani pregnant women's nails, used as a biomarker, were measured to estimate the lead exposure. Thirteen nail samples out of 84 nails analyzed contained lead higher than the concentration (13.6 μg/g) of the fatal lead poisoning case, raising the possibility of an external contamination. Eye cosmetics such as surma are recognized as one of the important sources of lead exposure in Pakistan. We collected in Pakistan 30 eye cosmetics made in Pakistan, Saudi Arabia and western countries. As the metal composition analysis by energy dispersive X-ray fluorescence spectrometry revealed that some surma samples contained lead more than 96%, the surma might contaminate the nail specimen. Scanning electron microscopy observations showed that lead-containing surma consists of fine particle of galena (ore of lead sulfide) in respirable dust range (less than 10 μm). In addition, relative in vitro bioavailability of lead in the surma was determined as 5.2%. Thus, lead-containing surma consists of inhalable and bioavailable particles, and it contributes an increased risk of lead exposure. Moreover, the relationship between the surma and the lead-contaminated nails by lead isotope ratios analysis indicated the potential of lead contamination in nails by surma. These results suggest that lead in the nails was derived both from body burden of lead and external contamination by lead-containing surma. Therefore, nail is not suited as a biomarker for lead exposure in the countries where surma used, because we may overestimate lead exposure by surface lead contamination in the nail by surma. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Arthrodesis of the knee with an intramedullary nail.

    PubMed

    Donley, B G; Matthews, L S; Kaufer, H

    1991-07-01

    The cases of twenty patients who had an arthrodesis in which an intramedullary nail was used for stabilization were reviewed at an average follow-up of six years. The predominant indications were infection after total knee arthroplasty and post-traumatic pain and instability. Other indications included aseptic loosening of the components of a total knee arthroplasty, reconstruction after resection of a giant-cell tumor, non-union of a fracture of the distal part of the femur or the proximal part of the tibia, and failed external-compression arthrodesis. Success was achieved in seventeen patients (85 per cent), and functional stability immediately postoperatively was gained in all twenty. Of the three patients in whom the arthrodesis failed, all had sustained an intraoperative fracture, and infection eventually developed. Of the twelve nails that were secured to the greater trochanter with a loop of stainless-steel wire, none showed evidence of proximal migration. Of the eight nails that were not thus secured, two migrated proximally, necessitating removal of the nail. Two drawbacks to this operation are the long duration and the large amount of blood that is lost. The major advantage is that a high percentage of patients have progression to a stable fusion despite serious problems. Furthermore, all but seven patients (including the six who had a tumor or who had sustained an intraoperative fracture) were able to bear full weight by the second postoperative week. Only a few patients needed an external support for walking.

  13. Arthrodesis of the knee with intramedullary nail fixation.

    PubMed

    Puranen, J; Kortelainen, P; Jalovaara, P

    1990-03-01

    Thirty-three patients had an arthrodesis of the knee by means of an intramedullary nail introduced through the greater trochanter. Fifteen of the procedures were done for a failed knee arthroplasty; eight had failed because of infection and seven, because of aseptic loosening. Twenty-nine of the thirty-three knees united three to four months after the first attempt at arthrodesis and three united after technical errors were corrected. One knee had a broken nail and a non-union; this was still untreated at the time of writing. Four nails broke: three in the line of fusion and one in the line of an infected supracondylar pseudarthrosis of the femur. No new infections developed after the arthrodesis. Three patients had had an infection and a chronic fistula before the arthrodesis, and the fistulae healed six, fourteen, and eighteen months postoperatively. In another patient, who had had infection and necrosis of the skin preoperatively, the wound healed in six months. All of these knees healed without an additional major operation. The functional result was satisfactory in all patients. After the arthrodesis, seventeen of the thirty-three patients needed less aid when walking, and no patient needed more aid. Fusion of the knee with a long intramedullary nail can be safe and effective, even in the presence of infection, if the revision is performed properly and certain technical principles are followed. It is especially important to establish good contact between the resected bones.

  14. Tibiotalocalcaneal arthrodesis with a curved, interlocking, intramedullary nail.

    PubMed

    Budnar, Vijaya M; Hepple, Steve; Harries, William G; Livingstone, James A; Winson, Ian

    2010-12-01

    Tibiotalocalcaneal fusion with a straight rod has a risk of damaging the lateral plantar neurovascular structures and may interfere with maintaining normal heel valgus position.We report the results of a prospective study of tibiotalocalcaneal (TTC) arthrodesis with a short, anatomically curved interlocking, intramedullary nail. Forty-five arthrodesis in 42 patients, performed between Jan 2003 and Oct 2008, were prospectively followed. The mean followup was 48 (range, 10 to 74) months. The main indications for the procedure were failed ankle arthrodesis with progressive subtalar arthritis, failed ankle arthroplasty and complex hindfoot deformity. The outcome was measured by a combination of pre and postoperative clinical examination, AOFAS hindfoot scores, SF-12 scores and radiological assessment. Union rate was 89% (40/45). Eighty-two percent (37/45) reported improvement in pain and 73% (33/45) had improved foot function. Satisfactory hindfoot alignment was achieved in 84% (38/45). Postoperatively there was a mean improvement in the AOFAS score of 37. Complications included a below knee amputation for persistent deep infection, five nonunions, and three delayed unions. Four nails, six proximal and six distal locking screws were removed for various causes. Other complications included two perioperative fractures, four superficial wound infections and one case of lateral plantar nerve irritation. With a short, anatomically curved intramedullary nail, we had a high rate of tibiotalocalcaneal fusion with minimal plantar neurovascular complications. We believe a short, curved intramedullary nail, with its more lateral entry point, helped maintain hindfoot alignment.

  15. Nail Damage (Severe Onychodystrophy) Induced by Acrylate Glue: Scanning Electron Microscopy and Energy Dispersive X-Ray Investigations

    PubMed Central

    Pinteala, Tudor; Chiriac, Anca Eduard; Rosca, Irina; Larese Filon, Francesca; Pinteala, Mariana; Chiriac, Anca; Podoleanu, Cristian; Stolnicu, Simona; Coros, Marius Florin; Coroaba, Adina

    2017-01-01

    Background Scanning electron microscopy (SEM) and energy dispersive X-ray (EDX) techniques have been used in various fields of medical research, including different pathologies of the nails; however, no studies have focused on obtaining high-resolution microscopic images and elemental analysis of disorders caused by synthetic nails and acrylic adhesives. Methods Damaged/injured fingernails caused by the use of acrylate glue and synthetic nails were investigated using SEM and EDX methods. Results SEM and EDX proved that synthetic nails, acrylic glue, and nails damaged by contact with acrylate glue have a different morphology and different composition compared to healthy human nails. Conclusions SEM and EDX analysis can give useful information about the aspects of topography (surface sample), morphology (shape and size), hardness or reflectivity, and the elemental composition of nails. PMID:28232921

  16. Osteosynthesis of fractures of the femur with flexible metallic intramedullary nails.

    PubMed

    Firica, A; Troianescu, O; Petre, M

    1978-04-01

    The authors discuss their use of Ender's method in the treatment of fractures of the femur. The diameter and length of the nails depends on the type of fracture. 1) Three nails of 4 mm diameter are introduced in parallel from the medial condyle in fractures of the femoral neck; 2) 5 mm nails are used, in similar fashion, for the fixation of intertrochanteric and subtrochanteric fractures; 3) 5 mm nails are used for diaphyseal, supracondylar and intercondylar fractures, introduced in crossed fashion ("Eiffel Tower" technique) from both medial and lateral condyles. This method of fixation has proved to be extremely stable. The operation itself is quick, with no blood loss or shock. The patient can resume partial weight bearing after a week in stabilised intertrochanteric and shaft fractures, after a month in less stable types, and after three to four months in fractures of the neck of the femur. This report is based on the first 250 cases treated by this method.

  17. [Intramedullary nailing in diaphyseal clavicle fractures using minimally invasive percutaneous reduction].

    PubMed

    Müller, M; Freude, T; Stöckle, U; Kraus, T M

    2017-02-01

    Closed reduction and intramedullary nailing is common in diaphyseal clavicle fractures. The aim of this report is to demonstrate a surgical method with minimally invasive percutaneous reduction in cases where closed reduction fails. The procedure is associated with good cosmetic results. Percutaneous reduction using two reduction forceps enables intramedullary nailing without an open procedure. Open, multifragmented or non-dislocated fractures, oblique fractures due to postoperative dislocation or shortening risk, fracture having potential to become compound fractures, neurovascular complications, pseudoarthroses. The patient is in beach-chair position. After an incision, the nail is entered from medial, two reduction forceps are mounted percutaneously at the lateral and medial fragment. After reduction the nail is pushed forward into the lateral fragment. Thereby, the fracture hematoma is not disturbed for the most part. Early functional rehabilitation with maximal abduction and anteversion of 90° for 6 weeks. Anatomic reduction can be achieved with mild cosmetic impairment.

  18. 3D Optical Investigation of 2 Nail Systems Used in Tibiotalocalcaneal Arthrodesis: A Biomechanical Study.

    PubMed

    Evers, Julia; Lakemeier, Martin; Wähnert, Dirk; Schulze, Martin; Richter, Martinus; Raschke, Michael J; Ochman, Sabine

    2017-05-01

    Although retrograde intramedullary nails for tibiotalocalcaneal arthrodesis (TTCA) are an established fixation method, few studies have evaluated the stability of the available nail systems. The purpose of this study was to compare biomechanically the primary stability of 2 nail-systems, A3 (Small Bone Innovations) and HAN (Synthes), in human cadavers and analyze the exact point of instability in TTCA by means of optical measurement. In 6 pairs of lower legs (n = 12) of fresh-frozen human cadavers with osteoporotic bone structure, bone mineral density (BMD) was determined. Pairwise randomized implantation of either an HAN or A3 nail was executed. Performance and stability were measured by quasi-static tests using 3D motion tracking (NDI Optotrak-Certus) followed by cyclic loading tests during dorsi- and plantarflexion. 3D optical analysis in quasi-static tests showed a significantly lower degree of movement for the HAN nail in rotational and dorsi-/plantarflexion, especially in the subtalar joint. Cyclic loading tests were consistent with quasi-static tests. The A3 nail offered lower stability during axial torsion in the ankle and subtalar joints and during plantar- and dorsiflexion in the subtalar joint in osteoporotic bones. This study was the first to examine the primary stability of different arthrodesis nails in TTCA and their bony parts with a 3D motion analysis. The better stability of the locking-only HAN nail in this osteoporotic test setup could lead to more favorable results in comparison to the A3 nail in clinical use.

  19. Transitioning to an Intramedullary Lengthening and Compression Nail

    PubMed Central

    2017-01-01

    Summary: The magnetic intramedullary lengthening nail is an innovative technology that allows for creative ways to treat difficult problems. The lengthening option has revolutionized femur fracture management with bone loss and malunion therapy. The compression version of this nail has provided a gradual method to compress nonunions and difficult fractures that may obviate the need for many current uses of external fixation. Three cases are presented in this manuscript demonstrating a new paradigm in the management of bone loss/shortening of the tibia and femur, and recalcitrant nonunions. PMID:28486284

  20. Periarticular locking plate vs intramedullary nail for tibiotalocalcaneal arthrodesis: a biomechanical investigation.

    PubMed

    Ohlson, Blake L; Shatby, Meena W; Parks, Brent G; White, Kacey L; Schon, Lew C

    2011-02-01

    Augmented retrograde intramedullary (IM) nail fixation was compared with augmented periarticular locking- plate fixation for tibiotalocalcaneal arthrodesis. Specimens in 10 matched pairs were randomly assigned to a fixation construct and loaded cyclically in dorsiflexion. The groups did not differ in initial or final stiffness, load to failure, or construct deformation. No correlation was found between bone mineral density and construct deformation for either group. A humeral locking plate may be a viable alternative to an IM nail for tibiotalocalcaneal fixation in cases not amenable to IM nailing.

  1. Application of cosmetic nail varnish does not affect the antifungal efficacy of amorolfine 5% nail lacquer in the treatment of distal subungual toenail onychomycosis: results of a randomised active-controlled study and in vitro assays.

    PubMed

    Sigurgeirsson, B; Ghannoum, M A; Osman-Ponchet, H; Kerrouche, N; Sidou, F

    2016-05-01

    As onychomycosis is unsightly, this study clinically evaluated whether the antifungal efficacy of amorolfine 5% nail lacquer (NL) was affected by a masking, natural-coloured, cosmetic nail varnish applied 24 h later; in vitro investigations were also performed. Subjects with mild-to-moderate distal subungual toenail onychomycosis were randomised to receive amorolfine 5% NL once weekly with or without cosmetic nail varnish applied 24 h later. After 12-week treatment, antifungal activity of affected toenail clippings was assessed by measurement of zones of inhibition (ZOIs) on Trichophyton mentagrophytes seeded agar plates. Mean diameters were 53.5 mm for the amorolfine 5% NL-alone group (n = 23) and 53.6 mm for amorolfine 5% NL plus cosmetic nail varnish group (n = 25). Also, mycological cultures of subungual debris at week 12 were negative for all subjects in both groups. Most subjects (88%) reported that cosmetic nail varnish masked their infected toenails. Additionally, cadaver human nails coated in vitro with or without cosmetic nail varnish 10 min or 24 h post amorolfine NL application all gave ZOIs on Trichophyton rubrum agar plates representing potent antifungal activity. In conclusion, cosmetic nail varnish applied post amorolfine had no effect on the subungual antifungal activity of amorolfine 5% NL or its penetration through toenails. © 2016 The Authors Mycoses published by Blackwell Verlag GmbH.

  2. Knee fusion--a new technique using an old Belgian surgical approach and a new intramedullary nail.

    PubMed

    Alt, V; Seligson, D

    2001-02-01

    Knee arthrodesis is a useful procedure in difficult cases such as failed total knee arthroplasty, severe articular trauma, bone tumors, and infected knee joints. The most common techniques for knee fusion include external fixation and intramedullary nailing. Küntscher's nail is driven antegrade from the intertrochanteric region into the knee. We describe a new technique for knee arthrodesis using a new intramedullary nail and an old Belgian surgical approach to the knee joint published by Lambotte in 1913. This approach provides excellent exposure for the implantation of the nail by osteotomizing the patella vertically. The nail is implanted using HeyGroves method, whereby the nail is inserted retrograde into the femur and pulled distally anterograde into the tibia. We now use this technique as our standard procedure for knee fusion.

  3. [Residue of organic fluorine pollutants in hair and nails collected from Tianjin].

    PubMed

    Yao, Dan; Zhang, Hong; Chai, Zhi-Fang; Shen, Jin-Can; Yang, Bo; Wang, Yan-Ping; Liu, Guo-Qing

    2013-02-01

    In order to explore the residue and distributions of organic fluorine pollutants in hair and nails, the residue levels of total fluorine (TF), extractable organic fluorine (EOF) and perfluorinated chemicals (PFCs) in hair and nails collected from Tianjin adults were measured by the cyclic neutron activation analysis (CNAA) combined with the high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The results showed that inorganic fluorine (mean: 2.0 mg.kg-1, 4.5 mg.kg-1) was the primary fluorine in TF while EOF(mean: 0.7 mg.kg-1, 1.8 mg.kg-1) was minor. The average amount of identified fluorine (IF) was 0.038 mg.kg-1 in hair and 0.047 mg.kg-1 in nails, accounting or 7.1% (2.6%-16%) and 3.5% (1.1%-11%) of EOF, respectively, which indicated that more than 84% of EOF was unknown. The major residue in hair and nails were medium-and short-chain PFCs,in which perfluorooctane sulfonate, perfluorooctanoic acid and perfluorononanoic acid were the main species. TF, EOF and IF levels in dyed and permed hair were significantly higher than untreated hair (P <0.05), and the concentrations of Sigma PFCs in hair and nails showed no difference between genders. With significantly higher levels of sigma PFCs and PFOS residues than hair (P <0.01), nails could potentially become a more sensitive bioindicator for the exposure level of PFCs in human.

  4. Management of Infection After Intramedullary Nailing of Long Bone Fractures: Treatment Protocols and Outcomes

    PubMed Central

    Makridis, Kostas G; Tosounidis, Theodoros; Giannoudis, Peter V

    2013-01-01

    Implant related sepsis is a relatively unusual complication of intra-medullary nail fixation of long bone fractures. Depending on the extent of infection, timing of diagnosis and progress of fracture union, different treatment strategies have been developed. The aim of this review article is to collect and analyze the existing evidence about the incidence and management of infection following IM nailing of long bone fractures and to recommend treatment algorithms that could be valuable in everyday clinical practice. After searching the P u b M e d /Medline databases, 1270 articles were found related to the topic during the last 20 years. The final review included 28 articles that fulfilled the inclusion criteria. Only a few prospective studies exist to report on the management of infection following IM nailing of long-bone fractures. In general, stage I (early) infections only require antibiotic administration with/without debridement. Stage II (delayed) infections can be successfully treated with debridement, IM reaming, antibiotic nails, and administration of antibiotics. Infected non-unions are best treated with exchange nailing, antibiotic administration and when infection has been eradicated with graft implantation if it is needed. Debridement, exchange nailing and systemic administration of antibiotics is the best indication for stage III (late) infections, while stage III infected non-unions can successfully be treated with nail removal and Ilizarov frame, especially when large bone defects exist. PMID:23919097

  5. Can the tibial slope be measured on lateral knee radiographs?

    PubMed

    Faschingbauer, M; Sgroi, M; Juchems, M; Reichel, H; Kappe, T

    2014-12-01

    The posterior tibial slope influences both the natural knee stability as well as the stability and kinematics after total knee arthroplasty (TKA). Exact definition of the posterior tibial slope (PTS) requires lateral radiographs of the lower limb. Only lateral knee radiographs are routinely obtained after TKA, however. The purpose of the present study therefore was to analyse the relationship between PTS measurement results on short and expanded lateral knee radiographs. The PTS was measured on 100 consecutive lateral radiographs of the lower limb using the mechanical and three diaphyseal axes with various distances below the tibial plateau. Significant differences between PTS results were found for all three diaphyseal axes, with the smallest differences and the strongest correlation for a diaphyseal axis at 16 and 20 cm below the tibial plateau. Using short distances below the tibial plateau (6 and 10 cm) resulted in an overestimation of the PTS of 3°, on average. The PTS measurements in long lateral knee radiographs are more accurate compared to short radiographs. On short lateral knee radiographs, only a estimation of the PTS can be carried out. Diagnostic study, Level II.

  6. Road Nail: Experimental Solar Powered Intelligent Road Marking System

    NASA Astrophysics Data System (ADS)

    Samardžija, Dragan; Teslić, Nikola; Todorović, Branislav M.; Kovač, Erne; Isailović, Đorđe; Miladinović, Bojan

    2012-03-01

    Driving in low visibility conditions (night time, fog or heavy precipitation) is particularly challenging task with an increased probability of traffic accidents and possible injuries. Road Nail is a solar powered intelligent road marking system of wirelessly networked signaling devices that improve driver safety in low visibility conditions along hazardous roadways. Nails or signaling devices are autonomous nodes with capability to accumulate energy, exchange wireless messages, detect approaching vehicles and emit signalization light. We have built an experimental test-bed that consists of 20 nodes and a cellular gateway. Implementation details of the above system, including extensive measurements and performance evaluations in realistic field deployments are presented. A novel distributed network topology discovery scheme is proposed which integrates both sensor and wireless communication aspects, where nodes act autonomously. Finally, integration of the Road Nail system with the cellular network and the Internet is described.

  7. Low-Velocity Nail-Gun Injuries to the Interventricular Septum: Report of Two Cases, One in a Child.

    PubMed

    Michalsen, Kara L; Iguidbashian, John P; Kyser, James P; Long, William B

    2015-08-01

    Nail-gun injury to the heart is rare. Nail-gun injury to the interventricular septum is rarer: we could find only 5 reported cases, and none involving a child. We report 2 additional cases, in which nails penetrated the interventricular septum without causing acute pericardial tamponade, heart block, or shunt across the septum. Transesophageal echocardiography provides a dynamic way to evaluate the patient preoperatively, intraoperatively, and postoperatively. In the cases reported here, both the adult with multiple interventricular nails and the child with a single nail underwent foreign-object removal via median sternotomy. The child needed cardiopulmonary bypass for removal of the nail. There were no short-term or long-term sequelae from these interventricular septal injuries.

  8. Onychopharmacokinetics of terbinafine hydrochloride penetration from a novel topical formulation into the human nail in vitro.

    PubMed

    Hui, Xiaoying; Lindahl, Åke; Lamel, Sonia; Maibach, Howard I

    2013-09-01

    This study determined the onychopharmacokinetics, nail absorption, distribution, and penetration of [¹⁴C]-terbinafine HCl in a new topical formulation into/through the human finger nail using the in vitro finite dose model. This study determined the penetration rate of terbinafine HCl from multiple doses of topical formulation applied daily for 14 days. Results showed that the total dose recovery (mass balance) was almost 100%. The concentration of terbinafine HCl in the deeper nail plate (ventral/intermediate layers) and the cotton-pad nail bed samples after the 14-day treatment were 613 ± 145 and (±S.D.) and 27 ± 1.2 µg/cm³ (or 1.9 ± 0.6 µg/cm³ daily) on average, respectively. In comparison with nail concentration data from the literature for other topical terbinatine formulations, our results show that higher amounts of terbinafine HCl reached the deep nail plate and/or the nail bed after a 14-day topical treatment with this topical formulation in vitro.

  9. Percutaneous osteoplasty with a bone marrow nail for fractures of long bones: experimental study.

    PubMed

    Nakata, Kouhei; Kawai, Nobuyuki; Sato, Morio; Cao, Guang; Sahara, Shinya; Tanihata, Hirohiko; Takasaka, Isao; Minamiguchi, Hiroyuki; Nakai, Tomoki

    2010-09-01

    To develop percutaneous osteoplasty with the use of a bone marrow nail for fixation of long-bone fractures, and to evaluate its feasibility and safety in vivo and in vitro. Six long bones in three healthy swine were used in the in vivo study. Acrylic cement was injected through an 11-gauge bone biopsy needle and a catheter into a covered metallic stent placed within the long bone, creating a bone marrow nail. In the in vitro study, we determined the bending, tug, and compression strengths of the acrylic cement nails 9 cm long and 8 mm in diameter (N = 10). The bending strength of the artificially fractured bones (N = 6) restored with the bone marrow nail and cement augmentation was then compared with that of normal long bones (N = 6). Percutaneous osteoplasty with a bone marrow nail was successfully achieved within 1 hour for all swine. After osteoplasty, all swine regained the ability to run until they were euthanized. Blood tests and pathologic findings showed no adverse effects. The mean bending, tug, and compression strengths of the nail were 91.4 N/mm(2) (range, 75.0-114.1 N/mm(2)), 20.9 N/mm(2) (range, 6.6-30.4 N/mm(2)), and 103.0 N/mm(2) (range, 96.3-110.0 N/mm(2)), respectively. The bending strength ratio of artificially fractured bones restored with bone marrow nail and cement augmentation to normal long bone was 0.32. Percutaneous osteoplasty with use of a bone marrow nail and cement augmentation appears to have potential in treating fractures of non-weight-bearing long bones. Copyright 2010 SIR. Published by Elsevier Inc. All rights reserved.

  10. External fixation of tibial pilon fractures and fracture healing.

    PubMed

    Ristiniemi, Jukka

    2007-06-01

    Distal tibial fractures are rare and difficult to treat because the bones are subcutaneous. External fixation is commonly used, but the method often results in delayed union. The aim of the present study was to find out the factors that affect fracture union in tibial pilon fractures. For this purpose, prospective data collection of tibial pilon fractures was carried out in 1998-2004, resulting in 159 fractures, of which 83 were treated with external fixation. Additionally, 23 open tibial fractures with significant > 3 cm bone defect that were treated with a staged method in 2000-2004 were retrospectively evaluated. The specific questions to be answered were: What are the risk factors for delayed union associated with two-ring hybrid external fixation? Does human recombinant BMP-7 accelerate healing? What is the role of temporary ankle-spanning external fixation? What is the healing potential of distal tibial bone loss treated with a staged method using antibiotic beads and subsequent autogenous cancellous grafting compared to other locations of the tibia? The following risk factors for delayed healing after external fixation were identified: post-reduction fracture gap of >3 mm and fixation of the associated fibula fracture. Fracture displacement could be better controlled with initial temporary external fixation than with early definitive fixation, but it had no significant effect on healing time, functional outcome or complication rate. Osteoinduction with rhBMP-7 was found to accelerate fracture healing and to shorten the sick leave. A staged method using antibiotic beads and subsequent autogenous cancellous grafting proved to be effective in the treatment of tibial bone loss. Healing potential of the bone loss in distal tibia was at least equally good as in other locations of the tibia.

  11. Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures.

    PubMed

    Taylor, Benjamin C; Hansen, Dane C; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel

    2016-01-01

    Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted.

  12. Primary Retrograde Tibiotalocalcaneal Nailing For Fragility Ankle Fractures

    PubMed Central

    Taylor, Benjamin C.; Hansen, Dane C.; Harrison, Ryan; Lucas, Douglas E; Degenova, Daniel

    2016-01-01

    Background Ankle fragility fractures are difficult to treat due to poor bone quality and soft tissues as well as the near ubiquitous presence of comorbidities including diabetes mellitus and peripheral neuropathy. Conventional open reduction and internal fixation in this population has been shown to lead to a significant rate of complications. Given the high rate of complications with contemporary fixation methods, the present study aims to critically evaluate the use of acute hindfoot nailing as a percutaneous fixation technique for high-risk ankle fragility fractures. Methods In this study, we retrospectively evaluated 31 patients treated with primary retrograde tibiotalocalcaneal nail without joint preparation for a mean of 13.6 months postoperatively from an urban Level I trauma center during the years 2006-2012. Results Overall, there were two superficial infections (6.5%) and three deep infections (9.7%) in the series. There were 28 (90.3%) patients that went on to radiographic union at a mean of 22.2 weeks with maintenance of foot and ankle alignment. There were three cases of asymptomatic screw breakage observed at a mean of 18.3 months postoperatively, which were all treated conservatively.. Conclusions This study shows that retrograde hindfoot nailing is an acceptable treatment option for treatment of ankle fragility fractures. Hindfoot nailing allows early weightbearing, limited soft tissue injury, and a relatively low rate of complications, all of which are advantages to conventional open reduction internal fixation techniques. Given these findings, larger prospective randomized trials comparing this treatment with conventional open reduction internal fixation techniques are warranted. PMID:27528840

  13. Posterior tibial slope as a risk factor for anterior cruciate ligament rupture in soccer players.

    PubMed

    Senişik, Seçkin; Ozgürbüz, Cengizhan; Ergün, Metin; Yüksel, Oğuz; Taskiran, Emin; Işlegen, Cetin; Ertat, Ahmet

    2011-01-01

    Anterior cruciate ligament (ACL) is the primary stabilizer of the knee. An impairment of any of the dynamic or static stability providing factors can lead to overload on the other factors and ultimately to deterioration of knee stability. This can result in anterior tibial translation and rupture of the ACL. The purpose of this study was to examine the influence of tibial slope on ACL injury risk on soccer players. A total of 64 elite soccer players and 45 sedentary controls were included in this longitudinal and controlled study. The angle between the tibial mid-diaphysis line and the line between the anterior and posterior edges of the medial tibial plateau was measured as the tibial slope via lateral radiographs. Individual player exposure, and injuries sustained by the participants were prospectively recorded. Eleven ACL injuries were documented during the study period. Tibial slope was not different between soccer players and sedentary controls. Tibial slope in the dominant and non-dominant legs was greater for the injured players compared to the uninjured players. The difference reached a significant level only for the dominant legs (p < 0.001). While the tibial slopes of the dominant and non-dominant legs were not different on uninjured players (p > 0.05), a higher tibial slope was observed in dominant legs of injured players (p < 0.05). Higher tibial slope on injured soccer players compared to the uninjured ones supports the idea that the tibial slope degree might be an important risk factor for ACL injury. Key pointsDominant legs' tibial slopes of the injured players were significantly higher compared to the uninjured players (p < 0.001).Higher tibial slope was determined in dominant legs compared to the non-dominant side, for the injured players (p = 0.042). Different tibial slope measures in dominant and non-dominant legs might be the result of different loading and/or adaptation patterns in soccer.

  14. An evaluation of flexible intramedullary nail fixation in femoral shaft fractures in paediatric age group.

    PubMed

    Kumar, Sanjay; Roy, Sandip Kumar; Jha, Amrish Kumar; Chatterjee, Debdutta; Banerjee, Debabrata; Garg, Anant Kumar

    2011-06-01

    Sixty-two femoral shaft fractures in 60 patients treated by elastic intramedullary nailing with mean age of the patients being 9.2 years (range 5 years to 12 years) and average follow-up of 15 months (range 7 months to 60 months) are evaluated. Twenty-eight fractures were fixed with titanium elastic nail while 34 fractures were fixed with Enders nail. There were 40 midshaft fractures, 18 proximal femoral and 4 were fractures of distal third. Fracture patterns were transverse in 35, short oblique in 14 cases and 13 were spiral fractures. Mean age of union in this series was 17 weeks (range 12 weeks to 28 weeks). Ten cases had complications, 5 had nail tip irritation, 3 varus or valgus malalignment and 2 had delayed union. In this series, we did not have any non-union, refracture, limb length discrepancy or any major infection. The result demonstrates 100% union rate irrespective of the age, weight and height of the patient. Regardless of the site of fracture and their pattern, it united every time with elastic nail fixation. We did not find and mismatch in the results of fractures stabilised with titanium elastic nail with that of elastic stainless steel nail.

  15. Noise Source Identification and Dynamic Modeling of a Pneumatic Nailing Device =

    NASA Astrophysics Data System (ADS)

    Nili Ahmadabadi, Zahra

    Exposure to hazardous noise levels emitted by pneumatic nailing devices contributes significantly to risk of hearing damage among the construction workers throughout the world. This health problem comes from the lack of appropriate technology such as low noise devices which in turn results from the lack of scientific knowledge about designing reduced noise devices. This study contributes to the design improvement of pneumatic nailing devices through identifying the noise sources and developing the simulation tool required to redesign the pneumatic nailing device. To identify the noise sources, the study uses a combination of two complementary experimental approaches. The first makes use of time-synchronized data analysis of several variables during the machine operation. This strategy allows identifying the physical processes and provides a detailed separation of the noise generation mechanisms in successive time sequences. However, since multiple noise sources radiate at the same time, this observation approach is not sufficient for noise source identification and ranking. Thus, it is completed by a selective wrapping and muffler procedure. This technique provides overall generated noise associated with each process, as well as ranking of the three major sources: (1) exhaust noise, (2) machine body vibrations, and (3) workpiece vibrations. A special investigation is conducted on this third one with two cases: a workpiece/worktable setup representative of the actual field usage of a nailing device and a workpiece/sandbox setup used in a standardized laboratory test. The study evaluates the efficiency of the workpiece/sandbox setup in reducing the workpiece radiation and obtains a typical workpiece contribution on an actual worksite. To provide a simulation tool, a dynamic model of the pneumatic nailing device needs to be developed. Dynamic modeling of the nailing device requires mathematical modeling of the physical processes involved in its operation. All of these

  16. Focal osteolysis at the junctions of a modular stainless-steel femoral intramedullary nail.

    PubMed

    Jones, D M; Marsh, J L; Nepola, J V; Jacobs, J J; Skipor, A K; Urban, R M; Gilbert, J L; Buckwalter, J A

    2001-04-01

    During routine follow-up of patients treated with a three-piece stainless-steel modular femoral nail, osteolysis and periosteal reaction around the modular junctions of some of the nails were noted on radiographs. The purpose of this study was to evaluate the prevalence, etiology, and clinical relevance of these radiographic findings. Forty-four femoral fractures or nonunions in forty-two patients were treated with a modular stainless-steel femoral intramedullary nail. Seventeen nails were excluded, leaving twenty-seven intramedullary nails in twenty-seven patients for this study. All patients had had a femoral diaphyseal fracture; nineteen had had an acute fracture and eight, a nonunion. These twenty-seven patients returned for radiographs, a physical examination, assessment of functional outcomes, assessment of thigh pain with a visual analog scale, determination of serum chromium levels, and nail removal if desired. A control group of sixteen patients treated with a one-piece stainless-steel femoral intramedullary nail was evaluated with use of the same outcome measures and was compared with the group treated with the modular femoral nail with regard to prevalence of thigh pain and serum chromium levels. Twelve modular femoral nails were removed according to the study protocol. The modular nail junctions were analyzed for corrosion products, and histopathologic analysis of tissue specimens from the femoral canal was performed. The twenty-seven patients were seen at a mean of twenty-one months after fracture fixation; twenty-six of the twenty-seven fractures healed. Twenty-three femora had at least one of three types of abnormalities-osteolysis, periosteal reaction, or cortical thickening--localized to one or both modular junctions. Eighteen patients had severe reactions, defined as osteolysis of > or =2 mm, cortical thickening of > or =5 mm, and/or a periosteal reaction (group 1). Nine patients had mild or no reactions (group 2). Serum chromium levels in group 1

  17. 21 CFR 888.3590 - Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Knee joint tibial (hemi-knee) metallic resurfacing... Knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis. (a) Identification. A knee joint tibial (hemi-knee) metallic resurfacing uncemented prosthesis is a device intended to be implanted...

  18. Intramedullary nails with two lag screws.

    PubMed

    Brown, C J; Wang, C J; Yettram, A L; Procter, P

    2004-06-01

    To investigate the structural integrity of intramedullary nails with two lag screws, and to give guidance to orthopaedic surgeons in the choice of appropriate devices. Alternative designs of the construct are considered, and the use of a slotted upper lag screw insertion hole is analysed. Intramedullary fixation devices with a single lag screw have been known to fail at the lag screw insertion hole. Using two lag screws is considered. It has also been proposed to use a slot in the nail for the upper lag screw to prevent the upper lag screw from sticking. Bending and torsion load cases are analysed using finite element method. Consideration of both load conditions is essential. The results present the overall stiffness of the assembly, the load sharing between lag screws, and the possibility for cut-out to occur. While the slot for the upper lag screw might be advantageous with regard to the stresses in the lag screws, it could be detrimental for cut-out occurring adjacent to the lag screws. Comparative analyses demonstrate that two lag screws may be advantageous in patients whose cancellous bone quality is good and who impose large loads on the lag screw/nail interface. However, the use of two screws might pre-dispose to failure by cut-out of the lag screws. The addition of a slotted hole for the upper lag screw appears to do nothing significant to reduce the risk of such a failure. Copyright 2004 Elsevier Ltd.

  19. 76 FR 75871 - Certain Steel Nails From the People's Republic of China: Final Rescission of Antidumping Duty New...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-05

    ... published in the Federal Register our preliminary notice to rescind the NSR with respect to Shanghai Colour... should be rescinded. \\1\\ Shanghai Colour Nail Co., Ltd. (aka, Shanghai Colour Nail Import & Export Co., Ltd.), and Wuxi Colour Nail Co., Ltd. (collectively ``Shanghai Colour''). \\2\\ See Certain Steel Nails...

  20. A preliminary survey of Vietnamese nail salon workers in Alameda County, California.

    PubMed

    Quach, Thu; Nguyen, Kim-Dung; Doan-Billings, Phuong-An; Okahara, Linda; Fan, Cathyn; Reynolds, Peggy

    2008-10-01

    In recent decades, the nail salon industry has been one of the fastest growing in the U.S. California has over 300,000 workers licensed to perform nail care services. Though little is known about their health, these workers routinely handle cosmetic products containing carcinogens and endocrine disruptors that may increase a woman's breast cancer risk. Additionally, an estimated 59-80% of California nail salons are run by Vietnamese women who face socio-cultural barriers that may compromise their workplace safety and health care access. In a pilot project designed to characterize Vietnamese nail salon workers in Alameda County, California in order to inform future health interventions and reduce occupational exposures, we conducted face-to-face surveys with a convenience sample of 201 Vietnamese nail salon workers at 74 salons. Of the workers surveyed, a majority reported that they are concerned about their health from exposure to workplace chemicals. Additionally, a sizeable proportion reported having experienced some health problem after they began working in the industry, particularly acute health problems that may be associated with solvent exposure (e.g. skin and eye irritation, breathing difficulties and headaches). Our findings highlight a critical need for further investigation into the breast cancer risk of nail salon workers, underscored by the workers' routine use of carcinogenic and endocrine-disrupting chemicals, their prevalent health concerns about such chemicals, and their high level of acute health problems. Moreover, the predominance of Vietnamese immigrant women in this workforce makes it an important target group for further research and health interventions.

  1. Nail-fold excision for the treatment of ingrown toenail in children.

    PubMed

    Haricharan, Ramanath N; Masquijo, Javier; Bettolli, Marcos

    2013-02-01

    To evaluate the effectiveness of the nail-fold excision procedure in children. Prospectively collected data on patients less than 18 years of age who underwent a nail-fold excision for symptomatic ingrown toenail were analyzed. Patients were seen in 2 centers and data collected included demographics, site of ingrown toenail, complications (including recurrence), patient satisfaction, and duration of follow-up. Overall, 67 procedures were performed on 50 patients between June 2009 and July 2011 at the 2 institutions. The mean age was 14 years (range, 9-18 years) and 30 were male patients. No recurrences were seen after a follow-up for a median of 14 months (range 6-28 months). Patients were very satisfied with the cosmetic outcomes. Six minor complications occurred, including 3 patients with bleeding requiring dressing change, 2 with excessive granulation tissue, and 1 with nail growth abnormality. The nail-fold excision technique is highly effective in the pediatric population, with no recurrence, excellent cosmesis, and very high patient satisfaction. Copyright © 2013 Mosby, Inc. All rights reserved.

  2. Interlocking Nailing Versus Interlocking Plating in Intra-articular Calcaneal Fractures: A Biomechanical Study.

    PubMed

    Reinhardt, Sophia; Martin, Heiner; Ulmar, Benjamin; Döbele, Stefan; Zwipp, Hans; Rammelt, Stefan; Richter, Martinus; Pompach, Martin; Mittlmeier, Thomas

    2016-08-01

    Open reduction and internal fixation with a plate is deemed to represent the gold standard of surgical treatment for displaced intra-articular calcaneal fractures. Standard plate fixation is usually placed through an extended lateral approach with high risk for wound complications. Minimally invasive techniques might avoid wound complications but provide limited construct stability. Therefore, 2 different types of locking nails were developed to allow for minimally invasive technique with sufficient stability. The aim of this study was to quantify primary stability of minimally invasive calcaneal interlocking nail systems in comparison to a variable-angle interlocking plate. After quantitative CT analysis, a standardized Sanders type IIB fracture model was created in 21 fresh-frozen cadavers. For osteosynthesis, 2 different interlocking nail systems (C-Nail; Medin, Nov. Město n. Moravě, Czech Republic; Calcanail; FH Orthopedics SAS; Heimsbrunn, France) as well as a polyaxial interlocking plate (Rimbus; Intercus GmbH; Rudolstadt, Germany) were used. Biomechanical testing consisted of a dynamic load sequence (preload 20 N, 1000 N up to 2500 N, stepwise increase of 100 N every 100 cycles, 0.5 mm/s) and a load to failure sequence (max. load 5000 N, 0.5 mm/s). Interfragmentary movement was detected via a 3-D optical measurement system. Boehler angle was measured after osteosynthesis and after failure occurred. No significant difference regarding load to failure, stiffness, Boehler angle, or interfragmentary motion was found between the different fixation systems. A significant difference was found with the dynamic failure testing sequence where 87.5% of the Calcanail implants failed in contrast to 14% of the C-Nail group (P < .01) and 66% of the Rimbus plate. The highest load to failure was observed for the C-Nail. Boehler angle showed physiologic range with all implants before and after the biomechanical tests. Both minimally invasive interlocking nail systems

  3. All-Polyethylene Tibial Components: An Analysis of Long-Term Outcomes and Infection.

    PubMed

    Houdek, Matthew T; Wagner, Eric R; Wyles, Cody C; Watts, Chad D; Cass, Joseph R; Trousdale, Robert T

    2016-07-01

    There is debate regarding tibial component modularity and composition in total knee arthroplasty (TKA). Biomechanical studies have suggested improved stress distribution in metal-backed tibias; however, these results have not translated clinically. The purpose of this study was to analyze the outcomes of all-polyethylene components and to compare the results to those with metal-backed components. We reviewed 31,939 patients undergoing a primary TKA over a 43-year period (1970-2013). There were 28,224 (88%) metal-backed and 3715 (12%) all-polyethylene tibial components. The metal-backed and all-polyethylene groups had comparable demographics with respect to gender, age and body mass index (BMI). Mean follow-up was 7 years. The mean survival for all primary TKAs at the 5-, 10-, 20- and 30-year time points was 95%, 89%, 73%, and 57%, respectively. All-polyethylene tibial components were found to have a significantly improved (P < .0001) survivorship when compared with their metal-backed counterparts. All-polyethylene tibial components were also found to have a significantly lower rate of infection, instability, tibial component loosening, and periprosthetic fracture. The all-polyethylene group had improved survival rates in all age groups, except in patients 85 years old or greater, where there was no significant difference. All-polyethylene tibial components had improved survival for all BMI groups except in the morbidly obese (BMI ≥ 40) where there was no significant difference. All-polyethylene tibial components had significantly improved implant survival, reduced rates of postoperative infection, fracture, and tibial component loosening. All polyethylene should be considered for most of the patients, regardless of age and BMI. Copyright © 2016 Elsevier Inc. All rights reserved.

  4. Complex Medial Meniscus Tears Are Associated With a Biconcave Medial Tibial Plateau.

    PubMed

    Barber, F Alan; Getelman, Mark H; Berry, Kathy L

    2017-04-01

    To determine whether an association exists between a biconcave medial tibial plateau and complex medial meniscus tears. A consecutive series of stable knees undergoing arthroscopy were evaluated retrospectively with the use of preoperative magnetic resonance imaging (MRI), radiographs, and arthroscopy documented by intraoperative videos. Investigators independently performed blinded reviews of the MRI or videos. Based on the arthroscopy findings, medial tibial plateaus were classified as either biconcave or not biconcave. A transverse coronal plane ridge, separating the front of the tibial plateau from the back near the inner margin of the posterior body of the medial meniscus, was defined as biconcave. The medial plateau slope was calculated with MRI sagittal views. General demographic information, body mass index, and arthroscopically confirmed knee pathology were recorded. A total of 179 consecutive knees were studied from July 2014 through August 2015; 49 (27.2%) biconcave medial tibial plateaus and 130 (72.8%) controls were identified at arthroscopy. Complex medial meniscus tears were found in 103. Patients with a biconcave medial tibial plateau were found to have more complex medial meniscus tears (69.4%) than those without a biconcavity (53.1%) (P = .049) despite having lower body mass index (P = .020). No difference in medial tibial plateau slope was observed for biconcavities involving both cartilage and bone, bone only, or an indeterminate group (P = .47). Biconcave medial tibial plateaus were present in 27.4% of a consecutive series of patients undergoing knee arthroscopy. A biconcave medial tibial plateau was more frequently associated with a complex medial meniscus tear. Level III, case-control study. Copyright © 2016 Arthroscopy Association of North America. All rights reserved.

  5. Total knee replacement-cementless tibial fixation with screws: 10-year results.

    PubMed

    Ersan, Önder; Öztürk, Alper; Çatma, Mehmet Faruk; Ünlü, Serhan; Akdoğan, Mutlu; Ateş, Yalım

    2017-12-01

    The aim of this study was to evaluate the long term clinical and radiological results of cementless total knee replacement. A total of 51 knees of 49 patients (33 female and 16 male; mean age: 61.6 years (range, 29-66 years)) who underwent TKR surgery with a posterior stabilized hydroxyapatite coated knee implant were included in this study. All of the tibial components were fixed with screws. The HSS scores were examined preoperatively and at the final follow-up. Radiological assessment was performed with Knee Society evaluating and scoring system. Kaplan-Meier survival analysis was performed to rule out the survival of the tibial component. The mean HSS scores were 45.8 (range 38-60) and 88.1 (range 61-93), preoperatively and at the final follow-up respectively. Complete radiological assessment was performed for 48 knees. Lucent lines at the tibial component were observed in 4 patients; one of these patients underwent a revision surgery due to the loosening of the tibial component. The 10-year survival rate of a tibial component was 98%. Cementless total knee replacement has satisfactory long term clinical results. Primary fixation of the tibial component with screws provides adequate stability even in elderly patients with good bone quality. Level IV, Therapeutic study. Copyright © 2017 Turkish Association of Orthopaedics and Traumatology. Production and hosting by Elsevier B.V. All rights reserved.

  6. Modified arthroscopic suture fixation of a displaced tibial eminence fracture.

    PubMed

    Lehman, Ronald A; Murphy, Kevin P; Machen, M Shaun; Kuklo, Timothy R

    2003-02-01

    This study describes a new arthroscopic method using a whip-stitch technique for treating a displaced type III tibial eminence fracture. A 12-year-old girl who sustained a displaced type III tibial eminence fracture was treated with arthroscopic fixation using the Arthrosew disposable suture device (Surgical Dynamics, Norwalk, CT) to place a whip stitch into the anterior cruciate ligament (ACL). The Arthrex ACL guide (Arthrex, Naples, FL) was used to reduce the avulsed tibial spine fragment. Sutures were then passed through the tibial tunnel and secured over a bony bridge with the knee in 20 degrees of flexion. At 9 months, the patient has a full range of motion with normal Lachman and anterior drawer testing, and she has returned to competitive basketball. Radiographs show complete fracture healing. KT-1000 and isokinetic testing at 9-month follow-up show only minimal side-to-side differences. The Arthrosew device provides a significant advantage in the treatment of type III and IV fractures of the tibial eminence by obtaining arthroscopic fixation within the substance of the ACL, thus obviating arthrotomy and hardware placement. This technique also restores the proper length and tension to the ACL, and provides a simplified, reproducible method of treatment for this injury.

  7. [Tibio-talo-calcaneal arthrodesis by retrograde intramedullary nail--a case report].

    PubMed

    Lipiński, Łukasz; Synder, Marek; Sibiński, Marcin

    2011-01-01

    We described a case of 64 year old overweight women, who was treated with revision tibio-talo-calcaneal artrodesis with the use of retrograde intramedullary nail. The procedure was performed after failed primary arthrodesis with the use of lateral approach and fibula osteotomy. Stabilization with intramedullary nail gave good clinical and functional result with a good bone healing.

  8. Side Effects: Skin and Nail Changes

    Cancer.gov

    Cancer treatments can cause skin to become dry, itchy, red, or peel. Nails may become dark, yellow, or cracked. Learn about signs of skin problems that may need urgent medical care. Get a helpful list of questions to ask your doctor.

  9. Stress relaxation of grouted entirely large diameter B-GFRP soil nail

    NASA Astrophysics Data System (ADS)

    Li, Guo-wei; Ni, Chun; Pei, Hua-fu; Ge, Wan-ming; Ng, Charles Wang Wai

    2013-08-01

    One of the potential solutions to steel-corrosion-related problems is the usage of fiber reinforced polymer (FRP) as a replacement of steel bars. In the past few decades, researchers have conducted a large number of experimental and theoretical studies on the behavior of small size glass fiber reinforce polymer (GFRP) bars (diameter smaller than 20 mm). However, the behavior of large size GFRP bar is still not well understood. Particularly, few studies were conducted on the stress relaxation of grouted entirely large diameter GFRP soil nail. This paper investigates the effect of stress levels on the relaxation behavior of GFRP soil nail under sustained deformation ranging from 30% to 60% of its ultimate strain. In order to study the behavior of stress relaxation, two B-GFRP soil nail element specimens were developed and instrumented with fiber Bragg grating (FBG) strain sensors which were used to measure strains along the B-GFRP bars. The test results reveal that the behavior of stress relaxation of B-GFRP soil nail element subjected to pre-stress is significantly related to the elapsed time and the initial stress of relaxation procedure. The newly proposed model for evaluating stress relaxation ratio can substantially reflect the influences of the nature of B-GFRP bar and the property of grip body. The strain on the nail body can be redistributed automatically. Modulus reduction is not the single reason for the stress degradation.

  10. Treatment of the femoral shaft fracture with a curved heat-treated COP clover-leaf nail.

    PubMed

    Onoue, Y; Sunami, Y; Fujiwara, H; Sadakane, T; Yasuda, S

    1979-01-01

    The commonly used straight intramedullary nail has certain limitations and disadvantages. Following radiographic and metallurgical studies we have developed a curved heat-treated clover-leaf nail using a newly developed precipitation hardening stainless steel (COP). The nail is bent with a slot on the convex side and the radius of curvature is 115 cm which corresponds to the anatomical antero-lateral convexity of the human femur. The nail has been satisfactory in clinical use since 1971 and has provided not only more stable internal fixation but also allowed fixation of fractures beyond the middle third of the shaft.

  11. Anterior tibial stress fractures treated with anterior tension band plating in high-performance athletes.

    PubMed

    Cruz, Alexandre Santa; de Hollanda, João Paris Buarque; Duarte, Aires; Hungria Neto, José Soares

    2013-06-01

    The non-surgical treatment of anterior tibial cortex stress fractures requires long periods of abstention from sports activities and often results in non-union. Many different surgical techniques have already been previously described to treat these fractures, but there is no consensus on the best treatment. We describe the outcome of treatment using anterior tibial tension band plating in three high-performance athletes (4 legs) with anterior tibial cortex stress fractures. Tibial osteosynthesis with a 3.5-mm locking compression plate in the anterolateral aspect of the tibia was performed in all patients diagnosed with anterior tibial stress fracture after September 2010 at Santa Casa Hospital. All of the fractures were consolidated within a period of 3 months after surgery, allowing for an early return to pre-injury levels of competitive sports activity. There were no infection, non-union, malunion or anterior knee pain complications. Anterior tibial tension band plating leads to prompt fracture consolidation and is a good alternative for the treatment of anterior tibial cortex stress fractures. Bone grafts were shown to be unnecessary.

  12. A Review of Indigo Naturalis as an Alternative Treatment for Nail Psoriasis.

    PubMed

    McDermott, Laura; Madan, Raman; Rupani, Reena; Siegel, Daniel

    2016-03-01

    Nail psoriasis is challenging to treat. The few currently available therapies are limited in efficacy, and often produce unfavorable side effects. A plant extract widely used in Traditional Chinese Medicine, indigo naturalis (Qing Dai), is presented in this review as an alternative topical treatment for skin and nail psoriasis. The purpose of this article is to present information on a viable alternative treatment with a favorable side effect profile for a difficult disease to treat. A PubMed search for the term "indigo naturalis" was performed, and literature from 2006 to the present relevant to indigo naturalis and treatment of psoriasis and nail psoriasis was reviewed. Indigo naturalis shares several therapeutic mechanisms with current psoriasis treatments, such as regulation of keratinocyte proliferation and differentiation, restoration of epidermal barrier function, and reduction of inflammatory processes. Clinically, it is well tolerated. Recent research of indigo naturalis suggests that it is a safe, inexpensive, and effective alternative topical treatment for skin and nail psoriasis.

  13. Metal-backed versus all-polyethylene tibial components in primary total knee arthroplasty

    PubMed Central

    2011-01-01

    Background and purpose The choice of either all-polyethylene (AP) tibial components or metal-backed (MB) tibial components in total knee arthroplasty (TKA) remains controversial. We therefore performed a meta-analysis and systematic review of randomized controlled trials that have evaluated MB and AP tibial components in primary TKA. Methods The search strategy included a computerized literature search (Medline, EMBASE, Scopus, and the Cochrane Central Register of Controlled Trials) and a manual search of major orthopedic journals. A meta-analysis and systematic review of randomized or quasi-randomized trials that compared the performance of tibial components in primary TKA was performed using a fixed or random effects model. We assessed the methodological quality of studies using Detsky quality scale. Results 9 randomized controlled trials (RCTs) published between 2000 and 2009 met the inclusion quality standards for the systematic review. The mean standardized Detsky score was 14 (SD 3). We found that the frequency of radiolucent lines in the MB group was significantly higher than that in the AP group. There were no statistically significant differences between the MB and AP tibial components regarding component positioning, knee score, knee range of motion, quality of life, and postoperative complications. Interpretation Based on evidence obtained from this study, the AP tibial component was comparable with or better than the MB tibial component in TKA. However, high-quality RCTs are required to validate the results. PMID:21895503

  14. Clinical and dermoscopic clues to differentiate pigmented nail bands: an International Dermoscopy Society study.

    PubMed

    Benati, E; Ribero, S; Longo, C; Piana, S; Puig, S; Carrera, C; Cicero, F; Kittler, H; Deinlein, T; Zalaudek, I; Stolz, W; Scope, A; Pellacani, G; Moscarella, E; Piraccini, B M; Starace, M; Argenziano, G

    2017-04-01

    Longitudinal melanonychia might be difficult to differentiate and the use of dermoscopy can be useful for the preoperative evaluation and management decision. The aim of our study was to investigate clinical and dermoscopic criteria of acquired longitudinal melanonychia in adults to identify the best predictors of melanoma using a multivariate analysis and to explore eventual new dermoscopic criteria for nail melanoma diagnosis. In this retrospective observational study, 82 histopathologically diagnosed, acquired nail pigmented bands were collected and examined. All variables were included in the analysis and examined as possible predictors of nail melanoma. Both univariate and multivariable analyses have been performed. Among 82 cases, 25 were diagnosed as nail melanoma and 57 as benign lesions (including 32 melanocytic nevi and 25 benign melanocytic hyperplasia). Melanoma cases were significantly associated with a width of the pigmented band higher than 2/3 of the nail plate, grey and black colours, irregularly pigmented lines, Hutchinson and micro-Hutchinson signs, and nail dystrophy. Granular pigmentation, a newly defined dermoscopic criterion, was found in 40% of melanomas and only in 3.51% of benign lesions. Dermoscopic examination of longitudinal melanonychia provides useful information that could help clinicians to improve melanoma recognition. © 2016 European Academy of Dermatology and Venereology.

  15. Penetrating brain injury caused by nail guns: two case reports and a review of the literature.

    PubMed

    Luo, Wei; Liu, Hai; Hao, Shuyu; Zhang, Ying; Li, Jingsheng; Liu, Baiyun

    2012-01-01

    To the best of the authors' knowledge, there are few case reports of penetrating brain injuries (PBI) caused by nail guns and these have usually involved incomplete penetration of the skull. Complete penetration of a nail into the intracranial cavity is extremely rare. Here, two such cases are presented. In the first, the nail entered through the right temporal bone, lodged in the right temporal lobe and was removed via craniotomy with intra-operative ultrasound guidance. In the second, the nail destroyed the left parietal bone, damaged the left internal capsule and lodged in the left temporal lobe near the left petrous apex and the brain stem. According to the latest literature retrieval, this is the first reported case of nail-gun injury to the internal capsule. The position of the nail precluded removal without further neurologic damage. Treatment strategies designed to optimize outcome, with or without surgery, and possible complications are discussed in this report.

  16. Effect of tibial plateau leveling on stability of the canine cranial cruciate-deficient stifle joint: an in vitro study.

    PubMed

    Reif, Ullrich; Hulse, Donald A; Hauptman, Joe G

    2002-01-01

    To evaluate the effect of tibial plateau leveling on joint motion in canine stifle joints in which the cranial cruciate ligament (CCL) had been severed. In vitro cadaver study. Six canine cadaver hind legs. Radiographs of the stifle joints were made to evaluate the tibial plateau angle with respect to the long axis of the tibia. The specimens were mounted in a custom-made testing device to measure cranio-caudal translation of the tibia with respect to the femur. An axial load was applied to the tibia, and its position was recorded in the normal stifle, after transection of the CCL, and after tibial plateau leveling. Further, the amount of caudal tibial thrust was measured in the tibial plateau leveled specimen while series of eight linearly increasing axial tibial loads were applied. Transection of the CCL resulted in cranial tibial translation when axial tibial load was applied. After tibial plateau leveling, axial loading resulted in caudal translation of the tibia. Increasing axial tibial load caused a linear increase in caudal tibial thrust in all tibial plateau-leveled specimens. After tibial plateau leveling, axial tibial load generates caudal tibial thrust, which increases if additional axial load is applied. Tibial plateau leveling osteotomy may prevent cranial translation during weight bearing in dogs with CCL rupture by converting axial load into caudal tibial thrust. The amount of caudal tibial thrust seems to be proportional to the amount of weight bearing. Copyright 2002 by The American College of Veterinary Surgeons

  17. Splitting of the Proximal Femur With a New Femoral Nail

    DTIC Science & Technology

    2010-04-01

    should be exercised with the use of new implants that require a change in customary technique. In addition, some concern must be raised by the amount of...the potential for gluteus medius tendon injury,8 whereas other authors have found greater soft-tissue injury by inserting a nail through the...Entry Femoral Nail (Synthes USA, Paoli, PA) moved the entry point further lateral (10 degrees) and distal to completely avoid the gluteus medius tendon

  18. Measurement of bone adjacent to tibial shaft fracture.

    PubMed

    Findlay, S C; Eastell, R; Ingle, B M

    2002-12-01

    Delayed union and non-union are common complications after fracture of the tibial shaft. Response of the surrounding bone as a fracture heals could be monitored using techniques currently used in the study of osteoporosis. The aims of our study were to: (1) evaluate the decrement in bone measurements made close to the fracture using dual-energy X-ray absorptiometry (DXA), quantitative ultrasound (QUS) and peripheral quantitative computed tomography (pQCT); (2) compare values for fractured versus non-fractured leg to determine the duration of decrement in bone measurements; and (3) calculate short-term precision in DXA, QUS and pQCT in order to calculate the ratio of decrement to precision (response ratio, RR) to determine the optimal test for monitoring changes after tibial fracture. The biggest decrement in bone measurements at the ipsilateral limb of 28 patients with tibial shaft fracture was observed at the pQCT tibial trabecular sites (distal = 19%, p<0.0001; proximal 5% = 21%, p<0.001; proximal 10% = 28%, p<0.001) and the ultradistal tibia/fibula measured by DXA (19%, p<0.0001). When comparing Z-scores, the magnitude of decrements at the ipsilateral limb was bigger for variables measured directly at the tibia, both proximal and distal to the fracture. The magnitude of the decrement in ultradistal tibia/fibula BMD decreased as the time since fracture increased ( r = 0.55). When response ratios are considered, pQCT measurements at the distal tibia (RR 6-8) and proximal 5% and 10% trabecular sites (RR 5 and 9 respectively) were found to be the most sensitive to change. Therefore, pQCT of the trabecular regions of either the proximal or distal tibia should prove the most sensitive measurement for monitoring changes in bone adjacent to a tibial shaft fracture.

  19. Ground reaction forces and bone parameters in females with tibial stress fracture.

    PubMed

    Bennell, Kim; Crossley, Kay; Jayarajan, Jyotsna; Walton, Elizabeth; Warden, Stuart; Kiss, Z Stephen; Wrigley, Tim

    2004-03-01

    Tibial stress fracture is a common overuse running injury that results from the interplay of repetitive mechanical loading and bone strength. This research project aimed to determine whether female runners with a history of tibial stress fracture (TSF) differ in ground reaction force (GRF) parameters during running, regional bone density, and tibial bone geometry from those who have never sustained a stress fracture (NSF). Thirty-six female running athletes (13 TSF; 23 NSF) ranging in age from 18 to 44 yr were recruited for this cross-sectional study. The groups were well matched for demographic, training, and menstrual parameters. A force platform measured selected GRF parameters (peak and time to peak for vertical impact and active forces, and horizontal braking and propulsive forces) during overground running at 4.0 m.s.(-1). Lumbar spine, proximal femur, and distal tibial bone mineral density were assessed by dual energy x-ray absorptiometry. Tibial bone geometry (cross-sectional dimensions and areas, and second moments of area) was calculated from a computerized tomography scan at the junction of the middle and distal thirds. There were no significant differences between the groups for any of the GRF, bone density, or tibial bone geometric parameters (P > 0.05). Both TSF and NSF subjects had bone density levels that were average or above average compared with a young adult reference range. Factor analysis followed by discriminant function analysis did not find any combinations of variables that differentiated between TSF and NSF groups. These findings do not support a role for GRF, bone density, or tibial bone geometry in the development of tibial stress fractures, suggesting that other risk factors were more important in this cohort of female runners.

  20. Allergic contact dermatitis from sculptured acrylic nails: special presentation with an airborne pattern

    PubMed Central

    Maio, Paula; Carvalho, Rodrigo; Amaro, Cristina; Santos, Raquel; Cardoso, Jorge

    2012-01-01

    Methylmethacrylate was first reported in 1941 as a cause of contact dermatitis. Since then, occupational contact allergies to acrylates in dentistry, orthopedic surgery, printing industry and industry have been reported, but few reports are found in the literature as a consequence of the contact with sculptured artificial acrylic nails which are increasingly popular. We describe here 3 patients with contact allergy to acrylates in artificial sculptured nails. Patch tests were performed with the Portuguese baseline series of contact allergens and an extended series of acrylates were applied. In particular, we tested three female patients with allergic contact dermatitis from sculptured acrylic nails. Two of these patients were both customers and also technical nail beauticians. Two patients developed periungual eczema; one presented only with face and eyelid dermatitis had no other lesions. The tests showed positive reaction to 2-hydroxyethylmethacrylate (2-HEMA) and 2-hydroxypropylmethacrylate (2-HPMA) in all the three patients. Our cases demonstrate the variety of clinical presentations of allergic contact dermatitis from acrylic sculptured nails. They show the need to warn patients of persistent and sometimes permanent side effects of these products. They also emphasize the importance of cosmetic ingredient labeling. PMID:25386316

  1. The effect of different torque wrenches on rotational stiffness in compressive femoral nails: a biomechanical study.

    PubMed

    Karaarslan, A A; Acar, N

    2018-02-01

    Rotation instability and locking screws failure are common problems. We aimed to determine optimal torque wrench offering maximum rotational stiffness without locking screw failure. We used 10 conventional compression nails, 10 novel compression nails and 10 interlocking nails with 30 composite femurs. We examined rotation stiffness and fracture site compression value by load cell with 3, 6 and 8 Nm torque wrenches using torsion apparatus with a maximum torque moment of 5 Nm in both directions. Rotational stiffness of composite femur-nail constructs was calculated. Rotational stiffness of composite femur-compression nail constructs compressed by 6 Nm torque wrench was 3.27 ± 1.81 Nm/angle (fracture site compression: 1588 N) and 60% more than that compressed with 3 Nm torque wrench (advised previously) with 2.04 ± 0.81 Nm/angle (inter fragmentary compression: 818 N) (P = 0.000). Rotational stiffness of composite-femur-compression nail constructs compressed by 3 Nm torque wrench was 2.04 ± 0.81 Nm/angle (fracture site compression: 818 N) and 277% more than that of interlocking nail with 0.54 ± 0.08 Nm/angle (fracture site compression: 0 N) (P = 0.000). Rotational stiffness and fracture site compression value produced by 3 Nm torque wrench was not satisfactory. To obtain maximum rotational stiffness and fracture site compression value without locking screw failure, 6 Nm torque wrench in compression nails and 8 Nm torque wrench in novel compression nails should be used.

  2. Bone microarchitecture of the tibial plateau in skeletal health and osteoporosis.

    PubMed

    Krause, Matthias; Hubert, Jan; Deymann, Simon; Hapfelmeier, Alexander; Wulff, Birgit; Petersik, Andreas; Püschel, Klaus; Amling, Michael; Hawellek, Thelonius; Frosch, Karl-Heinz

    2018-05-07

    Impaired bone structure poses a challenge for the treatment of osteoporotic tibial plateau fractures. As knowledge of region-specific structural bone alterations is a prerequisite to achieving successful long-term fixation, the aim of the current study was to characterize tibial plateau bone structure in patients with osteoporosis and the elderly. Histomorphometric parameters were assessed by high-resolution peripheral quantitative computed tomography (HR-pQCT) in 21 proximal tibiae from females with postmenopausal osteoporosis (mean age: 84.3 ± 4.9 years) and eight female healthy controls (45.5 ± 6.9 years). To visualize region-specific structural bony alterations with age, the bone mineral density (Hounsfield units) was additionally analyzed in 168 human proximal tibiae. Statistical analysis was based on evolutionary learning using globally optimal regression trees. Bone structure deterioration of the tibial plateau due to osteoporosis was region-specific. Compared to healthy controls (20.5 ± 4.7%) the greatest decrease in bone volume fraction was found in the medio-medial segments (9.2 ± 3.5%, p < 0.001). The lowest bone volume was found in central segments (tibial spine). Trabecular connectivity was severely reduced. Importantly, in the anterior and posterior 25% of the lateral and medial tibial plateaux, trabecular support and subchondral cortical bone thickness itself were also reduced. Thinning of subchondral cortical bone and marked bone loss in the anterior and posterior 25% of the tibial plateau should require special attention when osteoporotic patients require fracture fixation of the posterior segments. This knowledge may help to improve the long-term, fracture-specific fixation of complex tibial plateau fractures in osteoporosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Comparison of long-term results between osteo-odonto-keratoprosthesis and tibial bone keratoprosthesis.

    PubMed

    Charoenrook, Victor; Michael, Ralph; de la Paz, Maria Fideliz; Temprano, José; Barraquer, Rafael I

    2018-04-01

    To compare the anatomical and the functional results between osteo-odonto-keratoprosthesis (OOKP) and keratoprosthesis using tibial bone autograft (Tibial bone KPro). We reviewed the charts of 258 patients; 145 had OOKP whereas 113 had Tibial bone KPro implanted. Functional success was defined as best corrected visual acuity ≥0.05 on decimal scale and anatomical success as retention of the keratoprosthesis lamina. Kaplan-Meier survival curves were calculated for anatomical and functional survival as well as to estimate the probability of post-op complications. The anatomical survival for both KPro groups was not significantly different and was estimated as 67% for OOKP and 54% for Tibial bone KPro at 10 years after surgery. There was also no difference found after subdividing for primary diagnosis groups such as chemical injury, thermal burn, trachoma and all autoimmune cases combined. Estimated functional survival at 10 years post-surgery was 49% for OOKP and 25% for Tibial bone KPro, which was significantly different. The probability of patients with Tibial bone KPro developing one or more post-operative complications at 10 years after surgery (65%) was significantly higher than those with OOKP (40%). Mucous membrane necrosis and retroprosthetic membrane formation were more common in Tibial bone KPro than OOKP. Both types of autologous biological KPro, OOKP and Tibial bone KPro, had statistically similar rate of keratoprosthesis extrusion. Although functional success rate was significantly higher in OOKP, it may have been influenced by a better visual potential in the patients in this group. Copyright © 2018 Elsevier Inc. All rights reserved.

  4. Unusual penetration of a construction nail through the orbit to the cranium: a case report.

    PubMed

    Erkutlu, Ibrahim; Alptekin, Mehmet; Dokur, Mehmet; Geyik, Murat; Gök, Abdulvahap

    2011-01-01

    Penetrating head and neck trauma with construction nails are uncommon life-threatening injuries and an important problem in developing countries. Assessment of the neurovascular and systemic physical status is a first requirement, and the decision concerning which surgical approach to perform for the removal of the nail is of critical importance. A 10-year-old girl was presented one hour after a fall injury with complaint of a swelling and foreign body lodgment on the left forehead. Neurological and systemic physical examinations were normal except for weak direct pupillary light reflex on the left side and the patient's state of uneasiness. Radiological investigations showed that the head of the nail had entered from the left infra-orbital region and become lodged through the orbital roof, below the frontal bone. Surgical extraction of the nail in the operating room was performed successfully using left pterional craniotomy and lateral orbitotomy technique, and there was no complication after surgery. Here, we report a case with a rare craniocerebral penetrating wound and type, with the head of the nail lodged in the anterior fossa through the orbital roof, which may be defined as 'reverse penetration of the nail'.

  5. Effect of tibial slope on the stability of the anterior cruciate ligament-deficient knee.

    PubMed

    Voos, James E; Suero, Eduardo M; Citak, Musa; Petrigliano, Frank P; Bosscher, Marianne R F; Citak, Mustafa; Wickiewicz, Thomas L; Pearle, Andrew D

    2012-08-01

    We aimed to quantify the effect of changes in tibial slope on the magnitude of anterior tibial translation (ATT) in the anterior cruciate ligament (ACL)-deficient knee during the Lachman and mechanized pivot shift tests. We hypothesized that increased posterior tibial slope would increase the amount of ATT of an ACL-deficient knee, while leveling the slope of the tibial plateau would decrease the amount of ATT. Lachman and mechanized pivot shift tests were performed on hip-to-toe cadaveric specimens, and ATT of the lateral and the medial compartments was measured using navigation (n = 11). The ACL was then sectioned. Stability testing was repeated, and ATT was recorded. A proximal tibial osteotomy in the sagittal plane was then performed achieving either +5 or -5° of tibial slope variation after which stability testing was repeated (n = 10). Sectioning the ACL resulted in a significant increase in ATT in both the Lachman and mechanized pivot shift tests (P < 0.05). Increasing or decreasing the slope of the tibial plateau had no effect on ATT during the Lachman test (n.s.). During the mechanized pivot shift tests, a 5° increase in posterior slope resulted in a significant increase in ATT compared to the native knee (P < 0.05), while a 5° decrease in slope reduced ATT to a level similar to that of the intact knee. Tibial slope changes did not affect the magnitude of translation during a Lachman test. However, large changes in tibial slope variation affected the magnitude of the pivot shift.

  6. Soil nailing of a bridge embankment : report 2 : design and field performance report.

    DOT National Transportation Integrated Search

    1995-07-01

    Soil nailing has recently been introduced in Oregon as an alternative lateral earth support method. The first permanent soil nail wall on the state's highway system was used where an underpass was widened under the existing Oregon Slough Bridge in Po...

  7. 76 FR 16379 - Certain Steel Nails From the People's Republic of China: Final Results of the First Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ...) Maanshan Longer Nail Product Co., Ltd. (24) Nanjing Dayu Pneumatic Gun Nails Co., Ltd. (25) Qingdao.... (71) Tianjin Shishun Metallic Products Co., Ltd. (72) Tianjin Xiantong Fucheng Gun Nail Manufacture Co...

  8. Intramedullary nail fixation of non-traditional fractures: Clavicle, forearm, fibula.

    PubMed

    Dehghan, Niloofar; Schemitsch, Emil H

    2017-06-01

    Locked intramedullary fixation is a well-established technique for managing long-bone fractures. While intramedullary nail fixation of diaphyseal fractures in the femur, tibia, and humerus is well established, the same is not true for other fractures. Surgical fixations of clavicle, forearm and ankle are traditionally treated with plate and screw fixation. In some cases, fixation with an intramedullary device is possible, and may be advantageous. However, there is however a concern regarding a lack of rotational stability and fracture shortening. While new generation of locked intramedullary devices for fractures of clavicle, forearm and fibula are recently available, the outcomes are not as reliable as fixation with plates and screws. Further research in this area is warranted with high quality comparative studies, to investigate the outcomes and indication of these fractures treated with intramedullary nail devices compared to intramedullary nail fixation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  9. Tibial Acceleration and Spatiotemporal Mechanics in Distance Runners During Reduced-Body-Weight Conditions.

    PubMed

    Moran, Matthew F; Rickert, Brendan J; Greer, Beau K

    2017-05-01

    Treadmills that unload runners via a differential air-pressure (DAP) bladder (eg, AlterG Anti-Gravity Treadmill) are commonly used to reduce effective body weight (BW) in a clinical setting. However, the relationship between the level of unloading and tibial stress is currently unknown. To determine the relationship between tibial impact acceleration and level of BW unloading during running. Cross-sectional. University motion-analysis laboratory. 15 distance runners (9 male, 6 female; 20.4 ± 2.4 y, 60.1 ± 12.6 kg). Peak tibial acceleration and peak-to-peak tibial acceleration were measured via a uniaxial accelerometer attached to the tibia during a 37-min continuous treadmill run that simulated reduced-BW conditions via a DAP bladder. The trial began with a 10-min run at 100% BW followed by nine 3-min stages where BW was systematically reduced from 95% to 60% in 5% increments. There was no significant relationship between level of BW and either peak tibial acceleration or peak-to-peak tibial acceleration (P > .05). Both heart rate and step rate were significantly reduced with each 5% reduction in BW level (P < .01). Although ground-reaction forces are reduced when running in reduced-BW conditions on a DAP treadmill, tibial shock magnitudes are unchanged as an alteration in spatiotemporal running mechanics (eg, reduced step rate) and may nullify the unloading effect.

  10. Assessing indoor air quality in New York City nail salons.

    PubMed

    Pavilonis, Brian; Roelofs, Cora; Blair, Carly

    2018-05-01

    Nail salons are an important business and employment sector for recent immigrants offering popular services to a diverse range of customers across the United States. However, due to the nature of nail products and services, salon air can be burdened with a mix of low levels of hazardous airborne contaminants. Surveys of nail technicians have commonly found increased work-related symptoms, such as headaches and respiratory irritation, that are consistent with indoor air quality problems. In an effort to improve indoor air quality in nail salons, the state of New York recently promulgated regulations to require increased outdoor air and "source capture" of contaminants. Existing indoor air quality in New York State salons is unknown. In advance of the full implementation of the rules by 2021, we sought to establish reliable and usable baseline indoor air quality metrics to determine the feasibility and effectiveness of the requirement. In this pilot study, we measured total volatile organic compounds (TVOC) and carbon dioxide (CO 2 ) concentrations in 10 nail salons located in New York City to assess temporal and spatial trends. Within salon contaminant variation was generally minimal, indicating a well-mixed room and similar general exposure despite the task being performed. TVOC and CO 2 concentrations were strongly positively correlated (ρ = 0.81; p < 0.01) suggesting that CO 2 measurements could potentially be used to provide an initial determination of acceptable indoor air quality for the purposes of compliance with the standard. An almost tenfold increase in TVOC concentration was observed when the American National Standards Institute/American Society of Heating, Refrigerating and Air-Conditioning Engineers (ANSI/ASHRAE) target CO 2 concentration of 850 ppm was exceeded compared to when this target was met.

  11. The Effect of Tibial Plateau Levelling Osteotomy on Stifle Extensor Mechanism Load: A Canine Ex Vivo Study.

    PubMed

    Drew, Jarrod O; Glyde, Mark R; Hosgood, Giselle L; Hayes, Alex J

    2018-02-01

     To evaluate the effect of tibial plateau levelling osteotomy on stifle extensor mechanism load in an ex vivo cruciate-intact canine cadaveric model.   Ex vivo mechanical testing study.  Cadaveric canine pelvic limbs ( n  = 6).  A 21-mm tibial radial osteotomy was performed on pelvic limbs ( n  = 6) prior to being mounted into a load-bearing limb press. The proximal tibial segment was incrementally rotated until the anatomical tibial plateau angle had been rotated to at least 1°. The proportional change in stifle extensor mechanism load between the anatomical tibial plateau angle and the neutralized (∼6.5 degrees) and over-rotated (∼1°) tibial plateau angle was analysed using a one-sample t -test against a null hypothesis of no change. A p -value ≤0.05 was considered significant.  There was no significant change in the stifle extensor mechanism load from the anatomical tibial plateau angle (308 N [261-355 N]) to the neutralized tibial plateau angle (313 N [254-372 N]; p =.81), or from the anatomical tibial plateau angle to the over-rotated tibial plateau angle (303 N [254-352 N; p  = 0.67).  Tibial plateau levelling osteotomy does not significantly alter stifle extensor mechanism load at either a neutralized or over-rotated tibial plateau angle in our cruciate-intact model. Schattauer GmbH Stuttgart.

  12. [Magnetic resonance imaging of tibial periostitis].

    PubMed

    Meyer, X; Boscagli, G; Tavernier, T; Aczel, F; Weber, F; Legros, R; Charlopain, P; Martin, J P

    1998-01-01

    Tibial periostitis frequently occurs in athletes. We present our experience with MRI in a series of 7 patients (11 legs) with this condition. The clinical presentation and scintigraphic scanning suggested the diagnosis. MRI exploration of 11 legs demonstrated a high band-like juxta-osseous signal enhancement of SE and IR T2 weighted sequences in 6 cases, a signal enhancement after i.v. contrast administration in 4. Tibial periostitis is a clinical diagnosis and MRI and scintigraphic findings can be used to assure the differential diagnosis in difficult cases with stress fracture. MRI can visualize juxta-osseous edematous and inflammatory reactions and an increased signal would appear to be characteristic when the band-like image is fixed to the periosteum.

  13. 76 FR 22369 - Certain Steel Nails From the People's Republic of China: Initiation and Preliminary Results of...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-21

    ... Review AGENCY: Import Administration, International Trade Administration, Department of Commerce. DATES... review and a request to revoke, in part, the antidumping duty order on certain steel nails from the... nails. In addition to the four physical descriptions of steel nails, Petitioner requested three of the...

  14. Tibial component alignment and risk of loosening in unicompartmental knee arthroplasty: a radiographic and radiostereometric study.

    PubMed

    Barbadoro, P; Ensini, A; Leardini, A; d'Amato, M; Feliciangeli, A; Timoncini, A; Amadei, F; Belvedere, C; Giannini, S

    2014-12-01

    Unicompartmental knee arthroplasty (UKA) has shown a higher rate of revision compared with total knee arthroplasty. The success of UKA depends on prosthesis component alignment, fixation and soft tissue integrity. The tibial cut is the crucial surgical step. The hypothesis of the present study is that tibial component malalignment is correlated with its risk of loosening in UKA. This study was performed in twenty-three patients undergoing primary cemented unicompartmental knee arthroplasties. Translations and rotations of the tibial component and the maximum total point motion (MTPM) were measured using radiostereometric analysis at 3, 6, 12 and 24 months. Standard radiological evaluations were also performed immediately before and after surgery. Varus/valgus and posterior slope of the tibial component and tibial-femoral axes were correlated with radiostereometric micro-motion. A survival analysis was also performed at an average of 5.9 years by contacting patients by phone. Varus alignment of the tibial component was significantly correlated with MTPM, anterior tibial sinking, varus rotation and anterior and medial translations from radiostereometry. The posterior slope of the tibial component was correlated with external rotation. The survival rate at an average of 5.9 years was 89%. The two patients who underwent revision presented a tibial component varus angle of 10° for both. There is correlation between varus orientation of the tibial component and MTPM from radiostereometry in unicompartmental knee arthroplasties. Particularly, a misalignment in varus larger than 5° could lead to risk of loosening the tibial component. Prognostic studies-retrospective study, Level II.

  15. A clinical trial to investigate the effect of Cynatine HNS on hair and nail parameters.

    PubMed

    Beer, Christina; Wood, Simon; Veghte, Robert H

    2014-01-01

    A new, novel product, Cynatine HNS, was evaluated for its effects as a supplement for improving various aspects of hair and nails in a randomized, double-blind, placebo-controlled clinical trial. A total of 50 females were included and randomized into two groups. The active group (n = 25) received 2 capsules containing Cynatine HNS, comprised of Cynatine brand keratin (500 mg) plus vitamins and minerals, per day, and the placebo group (n = 25) received 2 identical capsules of maltodextrin per day for 90 days. End points for hair loss, hair growth, hair strength, amino acid composition, and hair luster were measured. End points were also measured for nail strength and the appearance of nails. The results show that subjects taking Cynatine HNS showed statistically significant improvements in their hair and nails when compared to placebo. Cynatine HNS is an effective supplement for improving hair and nails in 90 days or less. EudraCT number is 2014-002645-22.

  16. A Clinical Trial to Investigate the Effect of Cynatine HNS on Hair and Nail Parameters

    PubMed Central

    Veghte, Robert H.

    2014-01-01

    Objective. A new, novel product, Cynatine HNS, was evaluated for its effects as a supplement for improving various aspects of hair and nails in a randomized, double-blind, placebo-controlled clinical trial. Methods. A total of 50 females were included and randomized into two groups. The active group (n = 25) received 2 capsules containing Cynatine HNS, comprised of Cynatine brand keratin (500 mg) plus vitamins and minerals, per day, and the placebo group (n = 25) received 2 identical capsules of maltodextrin per day for 90 days. End points for hair loss, hair growth, hair strength, amino acid composition, and hair luster were measured. End points were also measured for nail strength and the appearance of nails. Results. The results show that subjects taking Cynatine HNS showed statistically significant improvements in their hair and nails when compared to placebo. Conclusion. Cynatine HNS is an effective supplement for improving hair and nails in 90 days or less. EudraCT number is 2014-002645-22. PMID:25386609

  17. Influence of the posterior tibial slope on the flexion gap in total knee arthroplasty.

    PubMed

    Okazaki, Ken; Tashiro, Yasutaka; Mizu-uchi, Hideki; Hamai, Satoshi; Doi, Toshio; Iwamoto, Yukihide

    2014-08-01

    Adjusting the joint gap length to be equal in both extension and flexion is an important issue in total knee arthroplasty (TKA). It is generally acknowledged that posterior tibial slope affects the flexion gap; however, the extent to which changes in the tibial slope angle directly affect the flexion gap remains unclear. This study aimed to clarify the influence of tibial slope changes on the flexion gap in cruciate-retaining (CR) or posterior-stabilizing (PS) TKA. The flexion gap was measured using a tensor device with the femoral trial component in 20 cases each of CR- and PS-TKA. A wedge plate with a 5° inclination was placed on the tibial cut surface by switching its front-back direction to increase or decrease the tibial slope by 5°. The flexion gap after changing the tibial slope was compared to that of the neutral slope measured with a flat plate that had the same thickness as that of the wedge plate center. When the tibial slope decreased or increased by 5°, the flexion gap decreased or increased by 1.9 ± 0.6mm or 1.8 ± 0.4mm, respectively, with CR-TKA and 1.2 ± 0.4mm or 1.1 ± 0.3mm, respectively, with PS-TKA. The influence of changing the tibial slope by 5° on the flexion gap was approximately 2mm with CR-TKA and 1mm with PS-TKA. This information is useful when considering the effect of manipulating the tibial slope on the flexion gap when performing CR- or PS-TKA. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. The Effect of Psychological State and Social Support on Nail-Biting in Adolescents: An Exploratory Study

    ERIC Educational Resources Information Center

    Sisman, Fatma Nevin; Tok, Ozlem; Ergun, Ayse

    2017-01-01

    Nail-biting is one of the most common behavioral problems in children. This study aimed to examine factors affecting nail-biting among adolescents and the effects of psychological state and social support on nail-biting. This cross-sectional study was conducted between January and May of 2014 in seven schools in Istanbul (N = 724). Data were…

  19. Pseudoaneurysm of the Anterior Tibial Artery following Ankle Arthroscopy in a Soccer Player.

    PubMed

    Tonogai, Ichiro; Matsuura, Tetsuya; Iwame, Toshiyuki; Wada, Keizo; Takasago, Tomoya; Goto, Tomohiro; Hamada, Daisuke; Kawatani, Yohei; Fujimoto, Eiki; Kitagawa, Tetsuya; Takao, Shyoichiro; Iwamoto, Seiji; Yamanaka, Moriaki; Harada, Masafumi; Sairyo, Koichi

    2017-01-01

    Ankle arthroscopy carries a lower risk of vascular complications when standard anterolateral and anteromedial portals are used. However, the thickness of the fat pad at the anterior ankle affords little protection for the thin-walled anterior tibial artery, rendering it susceptible to indirect damage during procedures performed on the anterior ankle joint. To our knowledge, only 11 cases of pseudoaneurysm involving the anterior tibial artery after ankle arthroscopy have been described in the literature. Here we reported a rare case of a 19-year-old soccer player who presented with pseudoaneurysm of the anterior tibial artery following ankle arthroscopy using an ankle distraction method and underwent anastomosis for the anterior tibial artery injury. Excessive distraction of the ankle puts the neurovascular structures at greater risk for iatrogenic injury of the anterior tibial artery during ankle arthroscopy. Surgeons should look carefully for postoperative ankle swelling and pain after ankle arthroscopy.

  20. Pseudoaneurysm of the Anterior Tibial Artery following Ankle Arthroscopy in a Soccer Player

    PubMed Central

    Iwame, Toshiyuki; Hamada, Daisuke; Fujimoto, Eiki; Kitagawa, Tetsuya; Takao, Shyoichiro; Iwamoto, Seiji; Yamanaka, Moriaki; Harada, Masafumi

    2017-01-01

    Ankle arthroscopy carries a lower risk of vascular complications when standard anterolateral and anteromedial portals are used. However, the thickness of the fat pad at the anterior ankle affords little protection for the thin-walled anterior tibial artery, rendering it susceptible to indirect damage during procedures performed on the anterior ankle joint. To our knowledge, only 11 cases of pseudoaneurysm involving the anterior tibial artery after ankle arthroscopy have been described in the literature. Here we reported a rare case of a 19-year-old soccer player who presented with pseudoaneurysm of the anterior tibial artery following ankle arthroscopy using an ankle distraction method and underwent anastomosis for the anterior tibial artery injury. Excessive distraction of the ankle puts the neurovascular structures at greater risk for iatrogenic injury of the anterior tibial artery during ankle arthroscopy. Surgeons should look carefully for postoperative ankle swelling and pain after ankle arthroscopy. PMID:28607785

  1. Treatment of humeral shaft fractures using antegrade nailing: functional outcome in the shoulder.

    PubMed

    Patino, Juan Martin

    2015-08-01

    The purpose of this study was to evaluate shoulder outcomes and function after humeral shaft fractures treated with antegrade nailing. Thirty patients with acute humeral shaft fractures who underwent antegrade locked intramedullary nailing were retrospectively studied. Range of motion (ROM) of the affected shoulder was evaluated, comparing it with the nonaffected shoulder, radiologic position of the nails, complications, and need for a second surgery. The study enrolled 20 men and 10 women (average age, 41.9 years). The average follow-up was 35.8 months. The average shoulder elevation averaged 157°, internal rotation was variable (reaching the sacroiliac joint to T7), and external rotation averaged 75°. Elbow flexion-extension ROM averaged 133° (115°-145°). According to the Rodriguez-Merchan criteria, 12 patients achieved excellent results (40%), 7 good (20%), and 6 fair (23.3%); poor results were found in 5 cases (16.6%). Twelve patients achieved full mobility of the shoulder, whereas 18 had some loss of motion, with significant differences between the affected and nonaffected shoulders (P = .001). Decreased shoulder ROM is common after antegrade nailing of humeral shaft fractures. Avoidance of nail impingement can improve final outcomes. Copyright © 2015 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  2. White Nail Radio Transmitter: Billion Dollar Savings through Energy Efficiency

    DTIC Science & Technology

    2011-05-10

    increase efficiency and reduce overall energy consumption ashore by 50 percent CNO, Navy Energy Vision, P 10 White Nail Vision Your Cell Phone Cell...Estimated Total Number of transmitters 3,000,000 Estimated total power saved Watt 1,250,000,000 Cell Phone Transmitter Efficiency 1.25 Gigawatts saved...Greenhouse Gas Power 4 1 Energy Navy Use 7.3 Billion kWh White Nail Cell Phone Savings 11 Billion kWh One and a half times!!! Saves the output of four of

  3. A 3D finite element model to investigate prosthetic interface stresses of different posterior tibial slope.

    PubMed

    Shen, Yi; Li, Xiaomiao; Fu, Xiaodong; Wang, Weili

    2015-11-01

    Posterior tibial slope that is created during proximal tibial resection in total knee arthroplasty has emerged as an important factor in the mechanics of the knee joint and the surgical outcome. But the ideal degree of posterior tibial slope for recovery of the knee joint function and preventions of complications remains controversial and should vary in different racial groups. The objective of this paper is to investigate the effects of posterior tibial slope on contact stresses in the tibial polyethylene component of total knee prostheses. Three-dimensional finite element analysis was used to calculate contact stresses in tibial polyethylene component of total knee prostheses subjected to a compressive load. The 3D finite element model of total knee prosthesis was constructed from the images produced by 3D scanning technology. Stresses in tibial polyethylene component were calculated with four different posterior tibial slopes (0°, 3°, 6° and 9°). The 3D finite element model of total knee prosthesis we presented was well validated. We found that the stress distribution in the polythene as evaluated by the distributions of the von Mises stress, the maximum principle stress, the minimum principle stress and the Cpress were more uniform with 3° and 6° posterior tibial slopes than with 0° and 9° posterior tibial slopes. Moreover, the peaks of the above stresses and trends of changes with increasing degree of knee flexion were more ideal with 3° and 6° posterior slopes. The results suggested that the tibial component inclination might be favourable to 7°-10° so far as the stress distribution is concerned. The range of the tibial component inclination also can decrease the wear of polyethylene. Chinese posterior tibial slope is bigger than in the West, and the current domestic use of prostheses is imported from the West, so their demands to tilt back bone cutting can lead to shorten the service life of prostheses; this experiment result is of important

  4. The Tibial Slope in Patients With Achondroplasia: Its Characterization and Possible Role in Genu Recurvatum Development.

    PubMed

    Brooks, Jaysson T; Bernholt, David L; Tran, Kevin V; Ain, Michael C

    2016-06-01

    Genu recurvatum, a posterior resting position of the knee, is a common lower extremity deformity in patients with achondroplasia and has been thought to be secondary to ligamentous laxity. To the best of our knowledge, the role of the tibial slope has not been investigated, and no studies describe the tibial slope in patients with achondroplasia. Our goals were to characterize the tibial slope in children and adults with achondroplasia, explore its possible role in the development of genu recurvatum, and compare the tibial slope in patients with achondroplasia to that in the general population. We reviewed 252 lateral knee radiographs of 130 patients with achondroplasia seen at our clinic from November 2007 through September 2013. Patients were excluded if they had previous lower extremity surgery or radiographs with extreme rotation. We analyzed patient demographics and, on all radiographs, the tibial slope. We then compared the mean tibial slope to norms in the literature. Tibial slopes >90 degrees had an anterior tibial slope and received a positive prefix. Statistical analysis included intraclass and interclass reliability, Pearson correlation coefficient, and the Student t tests (significance, P<0.05). The overall mean tibial slope for the 252 knees was +1.32±7 degrees, which was significantly more anterior than the normal slopes reported in the literature for adults (7.2 to 10.7 degrees, P=0.0001) and children (10 to 11 degrees, P=0.0001). The Pearson correlation coefficient for mean tibial slope and age showed negative correlations of -0.4011 and -0.4335 for left and right knees, respectively. This anterior tibial slope produces proximal and posterior vector force components, which may shift the knee posteriorly in weightbearing. The mean tibial slope is significantly more anterior in patients with achondroplasia than in the general population; however, this difference diminishes as patients' age. An anterior tibial slope may predispose to a more posterior

  5. Effects of diabetic peripheral neuropathy on gait in vascular trans-tibial amputees.

    PubMed

    Nakajima, Hiroshi; Yamamoto, Sumiko; Katsuhira, Junji

    2018-07-01

    Patients with diabetes often develop diabetic peripheral neuropathy, which is a distal symmetric polyneuropathy, so foot function on the non-amputated side is expected to affect gait in vascular trans-tibial amputees. However, there is little information on the kinematics and kinetics of gait or the effects of diabetic peripheral neuropathy in vascular trans-tibial amputees. This study aimed to clarify these effects, including the biomechanics of the ankle on the non-amputated side. Participants were 10 vascular trans-tibial amputees with diabetic peripheral neuropathy (group V) and 8 traumatic trans-tibial amputees (group T). Each subject's gait was analyzed at a self-selected speed using a three-dimensional motion analyzer and force plates. Ankle plantarflexion angle, heel elevation angle, and peak and impulse of anterior ground reaction force were smaller on the non-amputated side during pre-swing in group V than in group T. Center of gravity during pre-swing on the non-amputated side was lower in group V than in group T. Hip extension torque during loading response on the prosthetic side was greater in group V than in group T. These findings suggest that the biomechanical function of the ankle on the non-amputated side during pre-swing is poorer in vascular trans-tibial amputees with DPN than in traumatic trans-tibial amputees; the height of the center of gravity could not be maintained during this phase in vascular trans-tibial amputees with diabetic peripheral neuropathy. The hip joint on the prosthetic side compensated for this diminished function at the ankle during loading response. Copyright © 2018 Elsevier Ltd. All rights reserved.

  6. Closed retrograde retrieval of the distal broken segment of femoral cannulated intramedullary nail using a ball-tipped guide wire.

    PubMed

    Metikala, Sreenivasulu; Mohammed, Riazuddin

    2011-07-01

    Extracting broken segments of intramedullay nails from long bones can be an operative challenge, particularly from the distal end. We report a case series where a simple and reproducible technique of extracting broken femoral cannulated nails using a ball-tipped guide wire is described. This closed technique involves no additional equipment or instruments. Eight patients who underwent the described method were included in the study. The technique involves using a standard plain guide wire passed through the cannulated distal broken nail segment after extraction of the proximal nail fragment. The plain guide wire is then advanced distally into the knee joint carefully under fluoroscopy imaging. Over this wire, a 5-millimeter (mm) cannulated large drill bit is used to create a track up to the distal broken nail segment. Through the small knee wound, a ball-tipped guide wire is passed, smooth end first, till the ball engages the end of the nail. The guide wire is then extracted along with the broken nail through the proximal wound. The method was successfully used in all eight patients for removal of broken cannulated intramedullary nail from the femoral canal without any complications. All patients underwent exchange nailing with successful bone union in six months. None of the patients had any problems at the knee joint at the final follow-up. We report a technique for successful extraction of the distal fragment of broken femoral intramedullary nails without additional surgical approaches.

  7. Avulsion of the tibial tuberosity in a litter of greyhound puppies.

    PubMed

    Skelly, C M; McAllister, H; Donnelly, W J

    1997-10-01

    Avulsion of the tibial tuberosity was diagnosed in six of seven greyhound littermates aged five and a half months. The puppies showed hindlimb lameness of varying severity. Radiological assessment of affected stifle joints revealed partial or complete avulsion of the tibial tuberosities. In four puppies the lesions were bilateral. Euthanasia of the two most severely affected puppies was performed; the changes observed on histopathological examination of their cranioproximal tibiae suggested that the underlying lesion was that of osteochondrosis. A hereditary predisposition in greyhounds to osteochondrosis of the physis between the apophysis and the cranioproximal tibial diaphysis is postulated.

  8. Automated Measurement of Patient-Specific Tibial Slopes from MRI

    PubMed Central

    Amerinatanzi, Amirhesam; Summers, Rodney K.; Ahmadi, Kaveh; Goel, Vijay K.; Hewett, Timothy E.; Nyman, Edward

    2017-01-01

    Background: Multi-planar proximal tibial slopes may be associated with increased likelihood of osteoarthritis and anterior cruciate ligament injury, due in part to their role in checking the anterior-posterior stability of the knee. Established methods suffer repeatability limitations and lack computational efficiency for intuitive clinical adoption. The aims of this study were to develop a novel automated approach and to compare the repeatability and computational efficiency of the approach against previously established methods. Methods: Tibial slope geometries were obtained via MRI and measured using an automated Matlab-based approach. Data were compared for repeatability and evaluated for computational efficiency. Results: Mean lateral tibial slope (LTS) for females (7.2°) was greater than for males (1.66°). Mean LTS in the lateral concavity zone was greater for females (7.8° for females, 4.2° for males). Mean medial tibial slope (MTS) for females was greater (9.3° vs. 4.6°). Along the medial concavity zone, female subjects demonstrated greater MTS. Conclusion: The automated method was more repeatable and computationally efficient than previously identified methods and may aid in the clinical assessment of knee injury risk, inform surgical planning, and implant design efforts. PMID:28952547

  9. 78 FR 68472 - Steel Nails From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-14

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 731-TA-1114 (Review)] Steel Nails From China; Scheduling of an Expedited Five-Year Review Concerning the Antidumping Duty Order on Steel Nails From China... steel nails from China would be likely to lead to continuation or recurrence of material injury within a...

  10. A patient specific finite element simulation of intramedullary nailing to predict the displacement of the distal locking hole.

    PubMed

    Mortazavi, Javad; Farahmand, Farzam; Behzadipour, Saeed; Yeganeh, Ali; Aghighi, Mohammad

    2018-05-01

    Distal locking is a challenging subtask of intramedullary nailing fracture fixation due to the nail deformation that makes the proximally mounted targeting systems ineffective. A patient specific finite element model was developed, based on the QCT data of a cadaveric femur, to predict the position of the distal hole of the nail postoperatively. The mechanical interactions of femur and nail (of two sizes) during nail insertion was simulated using ABAQUS in two steps of dynamic pushing and static equilibrium, for the intact and distally fractured bone. Experiments were also performed on the same specimen to validate the simulation results. A good agreement was found between the model predictions and the experimental observations. There was a three-point contact pattern between the nail and medullary canal, only on the proximal fragment of the fractured bone. The nail deflection was much larger in the sagittal plane and increased for the larger diameter nail, as well as for more distally fractured or intact femur. The altered position of the distal hole was predicted by the model with an acceptable error (mean: 0.95; max: 1.5 mm, in different tests) to be used as the compensatory information for fine tuning of proximally mounted targeting systems. Copyright © 2018 IPEM. Published by Elsevier Ltd. All rights reserved.

  11. The microvascular and morphostructural changes of nails in psoriatic patients with nail disease; a link between ultrasound and videocapillaroscopy findings in the nailfold.

    PubMed

    Bakirci Ureyen, Sibel; Kara, Rabia Oztas; Erturk, Zeynep; Yaldiz, Mahizer

    2018-05-02

    The objective of this study is to evaluate the link between nail fold vessel resistive index (NVRI) measured by ultrasound (US) and capillary loops diameters measured using nailfold videocapillarascopy (NVC), and to assess the morphological appearance of the nail bed in patients with psoriatic nail disease (PND) as compared with healthy controls (HCs). This study was conducted in patients with PND and HCs. General demographic data were collected and clinical assessments were performed for all subjects. The nail plate thickness (NPT) was measured on gray scale using US. The NVRI was measured using color Doppler (CD) US. The measurements of the apical, arterial, venous limb diameters and morpho-structural changes (tortuous, cross-linked capillaries) were assessed using NVC. Thirty-four patients with PND and 15 HCs were enrolled in this study. The two groups were matched for age and body mass index (BMI). Patients with PND had higher NPT and NVRI in comparison with HCs [(20 (17-23) vs 14 (14-15), p<0.001), (0.55 (0.51-0.61) vs 0.43 (0.38-0.49), p<0.001), respectively]. A higher proportion of patients with PND had tortuous capillaries than HCs (62% and 20% respectively, p=0.005). The mean NVRI was higher in patients with PND who had tortuous capillaries than patients who did not have tortuous capillaries (0.58 (0.7) and 0.52 (0.09), respectively p=0.033). Microvascular changes can be detected easily using non-invasive methods such as US and NVC. These methods can provide an objective data to better assess PND.

  12. Comparison of tibial shaft ski fractures in children and adults.

    PubMed

    Hamada, Tomo; Matsumoto, Kazu; Ishimaru, Daichi; Sumi, Hiroshi; Shimizu, Katsuji

    2014-09-01

    To examine whether child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures. Descriptive epidemiological study. Prospectively analyzed the epidemiologic factors, injury types, and injury mechanisms at Sumi Memorial Hospital. This study analyzed information obtained from 276 patients with tibial fractures sustained during skiing between 2004 and 2012. We focused on 174 ski-related tibial shaft fractures with respect to the following factors: age, gender, laterality of fracture, skill level, mechanism of fracture (fall vs collision), scene of injury (steepness of slope), snow condition, and weather. Fracture pattern was graded according to Arbeitsgemeinschaft für Osteosynthesefragen (AO) classification and mechanical direction [external (ER) or internal rotation (IR)]. Tibial shaft fractures were the most common in both children (89.3%) and adults (47.4%). There were no significant differences in gender, side of fracture, mechanism of fracture, snow condition, or weather between children and adults. Skill levels were significantly lower in children than in adults (P < 0.0001). Type A fractures were more dominant in children (73 cases, 72.3%) than in adults (39 cases, 53.4%). There was significantly more ER in children than in adults (P < 0.0001). Among children, female patients had significantly more IR than ER; in contrast, among adults, women were injured by ER. We found significant differences in some of these parameters, suggesting that child and adult skiers have different risk factors or mechanisms of injury for tibial shaft fractures.

  13. Long-term complications following tibial plateau levelling osteotomy in small dogs with tibial plateau angles > 30°.

    PubMed

    Knight, Rebekah; Danielski, Alan

    2018-04-21

    Tibial plateau levelling osteotomy (TPLO) is commonly performed for surgical management of cranial cruciate ligament (CCL) disease. It has been suggested that small dogs may have steeper tibial plateau angles (TPAs) than large dogs, which has been associated with increased complication rates after TPLO. A retrospective study was performed to assess the rate and nature of long-term complications following TPLO in small dogs with TPAs>30°. Medical records were reviewed for dogs with TPAs>30° treated for CCL rupture by TPLO with a 2.0 mm plate over a five-year period. Radiographs were assessed to determine TPA, postoperative tibial tuberosity width and to identify any complication. Up-to-date medical records were obtained from the referring veterinary surgeon and any complications in the year after surgery were recorded. The effects of different variables on complication rate were assessed using logistic regression analysis. Minor complications were reported in 22.7 per cent of cases. This is similar to or lower than previously reported complication rates for osteotomy techniques in small dogs and dogs with steep TPAs. A smaller postoperative TPA was the only variable significantly associated with an increased complication rate. No major complications were identified. © British Veterinary Association (unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  14. What Components Comprise the Measurement of the Tibial Tuberosity-Trochlear Groove Distance in a Patellar Dislocation Population?

    PubMed

    Tensho, Keiji; Akaoka, Yusuke; Shimodaira, Hiroki; Takanashi, Seiji; Ikegami, Shota; Kato, Hiroyuki; Saito, Naoto

    2015-09-02

    The tibial tuberosity-trochlear groove distance is used as an indicator for medial tibial tubercle transfer; however, to our knowledge, no studies have verified whether this distance is strongly affected by tubercle lateralization at the proximal part of the tibia. We hypothesized that the tibial tuberosity-trochlear groove distance is mainly affected by tibial tubercle lateralization at the proximal part of the tibia. Forty-four patients with a history of patellar dislocation and forty-four age and sex-matched controls were analyzed with use of computed tomography. The tibial tuberosity-trochlear groove distance, tibial tubercle lateralization, trochlear groove medialization, and knee rotation were measured and were compared between the patellar dislocation group and the control group. The association between the tibial tuberosity-trochlear groove distance and three other parameters was calculated with use of the Pearson correlation coefficient and partial correlation analysis. There were significant differences in the tibial tuberosity-trochlear groove distance (p < 0.001) and knee rotation (p < 0.001), but there was no difference in the tibial tubercle lateralization (p = 0.13) and trochlear groove medialization (p = 0.08) between the patellar dislocation group and the control group. The tibial tuberosity-trochlear groove distance had no linear correlation with tubercle lateralization (r = 0.21) or groove medialization (r = -0.15); however, knee rotation had a good positive correlation in the patellar dislocation group (r = 0.62). After adjusting for the remaining parameters, knee rotation strongly correlated with the tibial tuberosity-trochlear groove distance (r = 0.69, p < 0.001), whereas tubercle lateralization showed moderate significant correlations in the patellar dislocation group (r = 0.42; p = 0.005). Because the tibial tuberosity-trochlear groove distance is affected more by knee rotation than by tubercle malposition, its use as an indicator for

  15. Practical Aspects of Posttrauma Reconstruction With an Intramedullary Lengthening Nail

    PubMed Central

    2017-01-01

    Summary: Limb equalization using the Ilizarov method has evolved and adapted the use of internal lengthening devices. One of the newest devices, termed “PRECICE,” is a magnetically controlled telescoping nail. Complications such as pin site infection and skin irritation are eliminated. Despite trauma surgeons’ familiarity with intramedullary nailing, the Ilizarov method requires sound knowledge of deformity analysis and awareness of specific complications associated with distraction osteogenesis. This manuscript discusses some of the practical preoperative and intraoperative components of limb lengthening. PMID:28486286

  16. [The direct AAS determination of micro elements in hair and nail by base-digestion].

    PubMed

    Ju, Hong-fang

    2002-08-01

    The study of micro elements is more and more extensively, and people can gain some informations by the level of micro elements in tissue. This paper tempts to dissolve hair or nail in 2 mol.L-1 NaOH and determinate nine micro elements including calcium, zinc, iron, manganese, nickel, cadmium, copper, lead and bismuth in them by base-digestion with FAAS and GFAAS. It shows that the measured value of these elements is coincident with reference articles reported, except bismuth. The elements' percent recoveries are 90.0%-110.8%. The result also shows that the level of zinc and copper in hair are higher than in nail, and the level of bismuth, cadmium and iron in hair are lower than in nail, but the level of micro elements in hair and in nail are not correlative.

  17. Standing balance in people with trans-tibial amputation due to vascular causes: A literature review.

    PubMed

    Seth, Mayank; Lamberg, Eric

    2017-08-01

    Balance is an important variable to consider during the rehabilitation process of individuals with trans-tibial amputation. Limited evidence exists on the balance abilities of people with trans-tibial amputation due to vascular causes. The purpose of this article is to review literature and determine if standing balance is diminished in people with trans-tibial amputation due to vascular causes. Literature review. Data were obtained from PubMed, Google Scholar, OandP.org , CINHAL, and Science Direct. Studies were selected only if they included standing balance assessment of people with unilateral trans-tibial amputation due to vascular causes. The review yielded seven articles that met the inclusion criteria. The general test methodology required participants to stand still on force platforms, with feet together, while center of pressure or postural sway was recorded. According to the findings of this review, individuals with trans-tibial amputees due to vascular causes have diminished balance abilities. Limited evidence suggests their balance might be further diminished as compared to individuals with trans-tibial amputation due to trauma. Although the evidence is limited, because of the underlying pathology and presence of comorbidities in individuals with trans-tibial amputation due to vascular causes, one cannot ignore these findings, as even a minor injury from a fall may develop into a non-healing ulcer and affect their health and well-being more severely than individuals with trans-tibial amputation due to trauma. Clinical relevance Individuals with trans-tibial amputation due to vascular causes have diminished balance abilities compared to healthy individuals and individuals with trans-tibial amputation due to trauma. This difference should be considered when designing and fabricating prostheses. Prosthetists and rehabilitation clinicians should consider designing amputation cause-specific rehabilitation interventions, focussing on balance and other

  18. Segmental transports for posttraumatic lower extremity bone defects: are femoral bone transports safer than tibial?

    PubMed

    Liodakis, Emmanouil; Kenawey, Mohamed; Krettek, Christian; Ettinger, Max; Jagodzinski, Michael; Hankemeier, Stefan

    2011-02-01

    The long-term outcomes following femoral and tibial segment transports are not well documented. Purpose of the study is to compare the complication rates and life quality scores of femoral and tibial transports in order to find what are the complication rates of femoral and tibial monorail bone transports and if they are different? We retrospectively analyzed the medical records of 8 femoral and 14 tibial consecutive segment transports performed with the monorail technique between 2001 and 2008 in our institution. Mean follow-up was 5.1 ± 2.1 years with a minimum follow-up of 2 years. Aetiology of the defects was posttraumatic in all cases. Four femoral (50%) and nine tibial (64%) fractures were open. The Short Form-36 (SF-36) health survey was used to compare the life quality after femoral and tibial bone transports. The Mann-Whiney U test, Fisher exact test, and the Student's two tailed t-test were used for statistical analysis. P ≤ 0.05 was considered to be statistically significant. The tibial transport was associated with higher rates of severe complications and additional procedures (1.5 ± 0.9 vs. 3.4 ± 2.7, p = 0.048). Three patients of the tibial group were amputated because of recurrent infections and one developed a complete regenerate insufficiency that was treated with partial diaphyseal tibial replacement. Contrary to that none of patients of the femoral group developed a complete regenerate insufficiency or was amputated. Tibial bone transports have a higher rate of complete and incomplete regenerate insufficiency and can more often end in an amputation. The authors suggest systematic weekly controls of the CRP value and of the callus formation in patients with posttraumatic tibia bone transports. Further comparative studies comparing the results of bone transports with and without intramedullary implants are necessary.

  19. Arthrodesis After Infected Revision TKA: Retrospective Comparison of Intramedullary Nailing and External Fixation.

    PubMed

    Iacono, Francesco; Francesco, Iacono; Raspugli, Giovanni Francesco; Francesco, Raspugli Giovanni; Bruni, Danilo; Danilo, Bruni; Lo Presti, Mirco; Mirco, Lo Presti; Sharma, Bharat; Bharat, Sharma; Akkawi, Ibrahim; Ibrahim, Akkawi; Marcacci, Maurilio; Maurilio, Marcacci

    2013-10-01

    Infection after revision total knee arthroplasty (TKA) for previous septic TKA can be a challenging problem to treat due to loss of bone stock and soft tissue integrity. In these cases, arthrodesis is a well-recognized salvage procedure. The aim of this retrospective study was to compare the results as described by a Visual Analogue Scale (VAS) and the Lequesne Algofunctional Score (LAS) of knee arthrodeses performed by using either an external fixator (EF) or an intramedullary nail (IM). The study included 34 knee arthrodesis divided in two groups: first group included 12 patients treated with EF and the second group of 22 patients dealt with IM nail. Clinical and functional evaluation was performed using the VAS and the LAS. Full-length radiographs were used to verify limb length discrepancy. VAS and LAS results showed a substantial improvement relative to preoperative condition in both groups. However, the LAS was significantly better in the IM nail group. The mean leg length discrepancy was significantly greater (4.5 cm) in the first group than in the second one (0.8 cm). No recurrence of infection was observed in the EF group while there were three recurrent infections in the IM nail group. Our study supported the existing literature and found that reinfection after revision TKA can be effectively treated with arthrodesis. In presence of massive bone loss, we recommend arthrodesis with IM nail used as an endoprosthesis, without bone-on-bone fusion, to produce a stable and painless knee, while preserving the limb length. Use of an IM nail allowed us to get a better functional result than EF.

  20. Physeal growth arrest after tibial lengthening in achondroplasia: 23 children followed to skeletal maturity.

    PubMed

    Song, Sang-Heon; Agashe, Mandar Vikas; Huh, Young-Jae; Hwang, Soon-Young; Song, Hae-Ryong

    2012-06-01

    Bilateral tibial lengthening has become one of the standard treatments for upper segment-lower segment disproportion and to improve quality of life in achondroplasia. We determined the effect of tibial lengthening on the tibial physis and compared tibial growth that occurred at the physis with that in non-operated patients with achondroplasia. We performed a retrospective analysis of serial radiographs until skeletal maturity in 23 achondroplasia patients who underwent bilateral tibial lengthening before skeletal maturity (lengthening group L) and 12 achondroplasia patients of similar height and age who did not undergo tibial lengthening (control group C). The mean amount of lengthening of tibia in group L was 9.2 cm (lengthening percentage: 60%) and the mean age at the time of lengthening was 8.2 years. The mean duration of follow-up was 9.8 years. Skeletal maturity (fusion of physis) occurred at 15.2 years in group L and at 16.0 years in group C. The actual length of tibia (without distraction) at skeletal maturity was 238 mm in group L and 277 mm in group C (p = 0.03). The mean growth rates showed a decrease in group L relative to group C from about 2 years after surgery. Physeal closure was most pronounced on the anterolateral proximal tibial physis, with relative preservation of the distal physis. Our findings indicate that physeal growth rate can be disturbed after tibial lengthening in achondroplasia, and a close watch should be kept for such an occurrence-especially when lengthening of more than 50% is attempted.

  1. High resolution ultrasonography of the tibial nerve in diabetic peripheral neuropathy.

    PubMed

    Singh, Kunwarpal; Gupta, Kamlesh; Kaur, Sukhdeep

    2017-12-01

    High-resolution ultrasonography of the tibial nerve is a fast and non invasive tool for diagnosis of diabetic peripheral neuropathy. Our study was aimed at finding out the correlation of the cross sectional area and maximum thickness of nerve fascicles of the tibial nerve with the presence and severity of diabetic peripheral neuropathy. 75 patients with type 2 diabetes mellitus clinically diagnosed with diabetic peripheral neuropathy were analysed, and the severity of neuropathy was determined using the Toronto Clinical Neuropathy Score. 58 diabetic patients with no clinical suspicion of diabetic peripheral neuropathy and 75 healthy non-diabetic subjects were taken as controls. The cross sectional area and maximum thickness of nerve fascicles of the tibial nerves were calculated 3 cm cranial to the medial malleolus in both lower limbs. The mean cross sectional area (22.63 +/- 2.66 mm 2 ) and maximum thickness of nerve fascicles (0.70 mm) of the tibial nerves in patients with diabetic peripheral neuropathy compared with both control groups was significantly larger, and statistically significant correlation was found with the Toronto Clinical Neuropathy Score ( p < 0.001). The diabetic patients with no signs of peripheral neuropathy had a larger mean cross sectional area (14.40 +/- 1.72 mm 2 ) and maximum thickness of nerve fascicles of the tibial nerve (0.40 mm) than healthy non-diabetic subjects (12.42 +/- 1.01 mm 2 and 0.30 mm respectively). The cross sectional area and maximum thickness of nerve fascicles of the tibial nerve is larger in diabetic patients with or without peripheral neuropathy than in healthy control subjects, and ultrasonography can be used as a good screening tool in these patients.

  2. Chronic shin splints. Classification and management of medial tibial stress syndrome.

    PubMed

    Detmer, D E

    1986-01-01

    A clinical classification and treatment programme has been developed for chronic medial tibial stress syndrome. Medial tibial stress syndrome has been reported to be either tibial stress fracture or microfracture, tibial periostitis, or distal deep posterior chronic compartment syndrome. Three chronic types exist and may coexist: Type I (tibial microfracture, bone stress reaction or cortical fracture); type II (periostalgia from chronic avulsion of the periosteum at the periosteal-fascial junction); and type III (chronic compartment syndrome syndrome). Type I disease is treated nonoperatively. Operations for resistant types II and III medial tibial stress syndrome were performed in 41 patients. Bilaterality was common (type II, 50% type III, 88%). Seven had coexistent type II/III; one had type I/II. Preoperative symptoms averaged 24 months in type II, 6 months in type III, and 33 months in types II/III. Mean age was 22 years (15 to 51). Resting compartment pressures were normal in type II (mean 12 mm Hg) and elevated in type III and type II/III (mean 23 mm Hg). Type II and type II/III patients received fasciotomy plus periosteal cauterisation. Type III patients had fasciotomy only. All procedures were performed on an outpatient basis using local anaesthesia. Follow up was complete and averaged 6 months (2 to 14 months). Improved performance was as follows: type II, 93%, type III, 100%; type II/III, 86%. Complete cures were as follows: type II, 78%; type III, 75%; and type II/III, 57%. This experience suggests that with precise diagnosis and treatment involving minimal risk and cost the athlete has a reasonable chance of return to full activity.

  3. Comparison of intraoperative anthropometric measurements of the proximal tibia and tibial component in total knee arthroplasty.

    PubMed

    Miyatake, Naohisa; Sugita, Takehiko; Aizawa, Toshimi; Sasaki, Akira; Maeda, Ikuo; Kamimura, Masayuki; Fujisawa, Hirokazu; Takahashi, Atsushi

    2016-09-01

    Precise matching of the tibial component and resected bony surfaces and proper rotational implanting of the tibial component are crucial for successful total knee arthroplasty. We aimed to analyze the exact anthropometric proximal tibial data of Japanese patients undergoing total knee arthroplasty and correlate the measurements with the dimensions of current total knee arthroplasty systems. A total of 703 knees in 566 Japanese patients who underwent total knee arthroplasty for osteoarthritis were included. The bone resection in the proximal tibia was performed perpendicular to the tibial axis in the frontal plane. Measurements of the proximal tibia were intraoperatively obtained after proximal tibial preparation. There were significant positive correlations between the lateral anteroposterior and medial anteroposterior and mediolateral dimensions. A progressive decrease in the mediolateral/lateral anteroposterior ratio with an increasing lateral anteroposterior dimension or the mediolateral/anteroposterior ratio with an increasing anteroposterior dimension was observed. The lateral anteroposterior dimension was smaller than the medial anteroposterior dimension by a mean of 4.8 ± 2.0 mm. The proximal tibia exhibited asymmetry between the lateral and medial plateaus. A comparison of the morphological data and dimensions of the implants, one of which was a symmetric tibial component (NexGen) and the others were asymmetric (Genesis II and Persona), indicated that an asymmetric tibial component could be beneficial to maximize tibial plateau coverage. This study provided important reference data for designing a proper tibial component for Japanese people. The proximal tibial cut surface was asymmetric. There was wide dispersion in the lateral anteroposterior, medial anteroposterior, and mediolateral dimensions depending on the patient. Our data showed that the tibial components of the Genesis II and Persona rather than that of the NexGen may be preferable for

  4. The study on length and diameter ratio of nail as preliminary design for slope stabilization

    NASA Astrophysics Data System (ADS)

    Gunawan, Indra; Silmi Surjandari, Niken; Muslih Purwana, Yusep

    2017-11-01

    Soil nailing technology has been widely applied in practice for reinforced slope. The number of studies for the effective design of nail-reinforced slopes has also increased. However, most of the previous study was focused on a safety factor of the slope; the ratio of length and diameter itself has likely never been studied before. The aim of this study is to relate the length and diameter ratio of the nail with the safety factor of the 20 m height of sand slope in the various angle of friction and steepness of the slope. Simplified Bishop method was utilized to analyze the safety factor of the slope. This study is using data simulation to calculate the safety factor of the slope with soil nailing reinforcement. The results indicate that safety factor of slope stability increases with the increase of length and diameter ratio of the nail. At any angle of friction and steepness of the slope, certain effective length and diameter ratio was obtain. These results may be considered as a preliminary design for slope stabilization.

  5. Intramedullary nailing: evolutions of femoral intramedullary nailing: first to fourth generations.

    PubMed

    Russell, Thomas A

    2011-12-01

    Intramedullary femoral nailing is the gold standard for femoral shaft fixation but only in the past 27 years. This rapid replacement of closed traction and cast techniques in North America was a controversial and contentious evolution in surgery. As we enter the fourth generation of implant design, capabilities, and surgical technique, it is important to understand the driving forces for this technology. These forces included changes in radiographic imaging capabilities, biomaterial design and computer-assisted manufacturing, and the recognition of the importance of mobilization of the trauma patient to avoid systemic complications and optimize functional recovery.

  6. [Tibiotalocalcaneal arthrodesis using a distally introduced femur nail (DFN)].

    PubMed

    Grass, René

    2005-10-01

    Simultaneous arthrodesis of ankle and subtalar joints and, at the same sitting, correction of axial malalignment of hindfoot, treatment of bony defects and of sequelae of circulatory disturbances after multiple previous interventions. Internal stabilization with a short distal femur nail. Restitution of a pain-free weight bearing. Failure of arthrodesis of ankle and subtalar joint causing pain in patients with severely altered bone structures particularly at the level of the talar dome. Malalignment of hind- and/or forefoot after previous arthrodesis of ankle and subtalar joint. Failure of conservative therapy in both above-enumerated conditions. Poor skin or soft-tissue conditions. Reflex sympathetic dystrophy. Acute osteitis/osteomyelitis. Posterolateral approach. Resection of the articular cartilage and the areas of sclerosis of the ankle and of the posterior facet of the subtalar joint. Interposition of bone grafts harvested from the iliac crest. Correction of malalignment of hind- and forefoot. Locked nailing with a short distal femur nail. Fitting of a flexible custom-made arthrodesis boot; weight bearing in boot not exceeding half of body weight until the 8th week. Gait training. After 12 weeks wearing of normal shoes. Radiographs after 6 and 12 weeks. Between February 1, 2002 and September 1, 2003 this technique was performed on 18 feet in 17 patients (three women, 14 men, average age 53 years [38.9-73.7 years]). Average duration of follow-up: 1.2 years (0.6-2.1 years). The goal of surgery was reached in all patients. Subjective assessment: 14 times good, three times satisfactory. Four complications: one loss of nail purchase, one dislocation of locking screw, one breakage of locking bolt, one prolonged bone healing.

  7. Pathomorphism of spiral tibial fractures in computed tomography imaging.

    PubMed

    Guzik, Grzegorz

    2011-01-01

    Spiral fractures of the tibia are virtually homogeneous with regard to their pathomorphism. The differences that are seen concern the level of fracture of the fibula, and, to a lesser extent, the level of fracture of the tibia, the length of fracture cleft, and limb shortening following the trauma. While conventional radiographs provide sufficient information about the pathomorphism of fractures, computed tomography can be useful in demonstrating the spatial arrangement of bone fragments and topography of soft tissues surrounding the fracture site. Multiple cross-sectional computed tomography views of spiral fractures of the tibia show the details of the alignment of bone chips at the fracture site, axis of the tibial fracture cleft, and topography of soft tissues that are not visible on standard radiographs. A model of a spiral tibial fracture reveals periosteal stretching with increasing spiral and longitudinal displacement. The cleft in tibial fractures has a spiral shape and its line is invariable. Every spiral fracture of both crural bones results in extensive damage to the periosteum and may damage bellies of the long flexor muscle of toes, flexor hallucis longus as well as the posterior tibial muscle. Computed tomography images of spiral fractures of the tibia show details of damage that are otherwise invisible on standard radiographs. Moreover, CT images provide useful information about the spatial location of the bone chips as well as possible threats to soft tissues that surround the fracture site. Every spiral fracture of the tibia is associated with disruption of the periosteum. 1. Computed tomography images of spiral fractures of the tibia show details of damage otherwise invisible on standard radiographs, 2. The sharp end of the distal tibial chip can damage the tibialis posterior muscle, long flexor muscles of the toes and the flexor hallucis longus, 3. Every spiral fracture of the tibia is associated with disruption of the periosteum.

  8. Anatomic relationship of the proximal nail matrix to the extensor hallucis longus tendon insertion.

    PubMed

    Palomo López, P; Becerro de Bengoa Vallejo, R; López López, D; Prados Frutos, J C; Alfonso Murillo González, J; Losa Iglesias, M E

    2015-10-01

    The purpose of this study was to delineate the relationship of the terminal extensor hallucis longus tendon insertion to the proximal limit of the nail matrix of the great toe. Fifty fresh-frozen human cadaver great toes with no evidence of trauma (average age, 62.5 years; 29 males and 21 females) were used for this study. Under 25X magnification, the proximal limit of the nail matrix and the terminal bony insertion of the extensor hallucis longus tendons were identified. The distance from the terminal tendon insertion to the nail matrix was ascertained using precision calipers, an optical microscope, and autocad(®) software for windows. Twenty-five great toes were placed in a neutral formalin solution and further analysed by histological longitudinal-sections. The specimens were stained with haematoxylin and eosin and examined microscopically to determine the presence of the extensor hallucis longus tendon along the dorsal aspect of the distal phalanx of each great toe. The main result we found in great toes was that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx in all, 100%, specimens. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of the distal phalanx as is the case for fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. We have found that the extensor tendon is between the matrix and the phalanx and extends dorsally to the distal aspect of the distal phalanx. The nail matrix of the great toe is not attached to the periosteum of the dorsal aspect of the base of distal phalanx as is the case in fingers, because the extensor hallucis tendon is plantar or directly underneath the nail matrix and the tendon is dorsal to the bone. Our anatomic study demonstrates that the proximal limit of the matrix and nail bed of the human great toe are dorsal and

  9. Complications of sodium hydroxide chemical matrixectomy: nail dystrophy, allodynia, hyperalgesia.

    PubMed

    Bostancı, Seher; Koçyiğit, Pelin; Güngör, Hilayda Karakök; Parlak, Nehir

    2014-11-01

    Ingrown toenails are seen most commonly in young adults, and they can seriously affect daily life. Partial nail avulsion with chemical matrixectomy, generally by using either sodium hydroxide or phenol, is one of the most effective treatment methods. Known complications of phenol matrixectomy are unpredictable tissue damage, prolonged postoperative drainage, increased secondary infection rates, periostitis, and poor cosmetic results. To our knowledge, there have been no reports about the complications related to sodium hydroxide matrixectomy. Herein, we describe three patients who developed nail dystrophy, allodynia, and hyperalgesia after sodium hydroxide matrixectomy.

  10. Sequential avulsions of the tibial tubercle in an adolescent basketball player.

    PubMed

    Huang, Ying Chieh; Chao, Ying-Hao; Lien, Fang-Chieh

    2010-05-01

    Tibial tubercle avulsion is an uncommon fracture in physically active adolescents. Sequential avulsion of tibial tubercles is extremely rare. We reported a healthy, active 15-year-old boy who suffered from left tibial tubercle avulsion fracture during a basketball game. He received open reduction and internal fixation with two smooth Kirschner wires and a cannulated screw, with every effort to reduce the plate injury. Long-leg splint was used for protection followed by programmed rehabilitation. He recovered uneventfully and returned to his previous level of activity soon. Another avulsion fracture happened at the right tibial tubercle 3.5 months later when he was playing the basketball. From the encouragement of previous successful treatment, we provided him open reduction and fixation with two small-caliber screws. He recovered uneventfully and returned to his previous level of activity soon. No genu recurvatum or other deformity was happening in our case at the end of 2-year follow-up. No evidence of Osgood-Schlatter disease or osteogenesis imperfecta was found. Sequential avulsion fractures of tibial tubercles are rare. Good functional recovery can often be obtained like our case if we treat it well. To a physically active adolescent, we should never overstate the risk of sequential avulsion of the other leg to postpone the return to an active, functional life.

  11. Several cases of undesirable effects caused by methacrylate ultraviolet-curing nail polish for non-professional use.

    PubMed

    Dahlin, Jakob; Berne, Berit; Dunér, Kari; Hosseiny, Sara; Matura, Mihály; Nyman, Gunnar; Tammela, Monica; Isaksson, Marléne

    2016-09-01

    Ultraviolet (UV)-curing nail polishes based on acrylates or methacrylates are currently also available for non-professional use. The Swedish Medical Products Agency recently prohibited one brand of UV-curing polish, because several consumers reported undesirable effects after using it. To investigate whether consumers with undesirable effects after using the UV-curing nail polish that was later prohibited were contact allergic to the polish and its individual ingredients. Eight patients who had reported severe skin reactions after the use of the UV-curing polish were patch tested with two coatings of the nail polish and its ingredients at five dermatology departments in Sweden. All patients tested except one showed contact allergic reactions to one or several of the acrylate-based or methacrylate-based ingredients in the nail polish. The non-professional use of UV-curing nail polishes poses a risk of sensitization from acrylates and methacrylates. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. Nail gun-induced open-globe injuries: a 10-year retrospective review.

    PubMed

    Kolomeyer, Anton M; Shah, Avni; Bauza, Alain M; Langer, Paul D; Zarbin, Marco A; Bhagat, Neelakshi

    2014-02-01

    To describe the characteristics of nail gun-related open-globe injuries. Retrospective series of all patients presenting with open globes secondary to nail gun injury from 2000 to 2010. Data were collected on demographics, setting of accident, presenting clinical examination findings, visual acuity, management, surgical procedures needed, and long-term outcomes. Forty-two patients (43 eyes; mean age, 31.6 years; 100% male; 79% Hispanic) suffered open-globe injury from nail gun accidents. Thirty-seven eyes (86%) sustained injury at work. One of 15 (6.7%) patients, on whom data were available, wore protective eyewear during the incident. Entrance wounds were classified into Zone I (n = 24 [56%]), Zone II (n = 12 [28%]), and Zone III (n = 7 [16%]). Six eyes (14%) had retained intraocular foreign bodies. Mean presenting logarithm of the minimum angle of resolution visual acuity was 1.64 ± 0.83, whereas mean final logarithm of the minimum angle of resolution visual acuity was 1.01 ± 0.96 (P = 0.004). Two eyes (4.7%) had no light perception vision at final examination. Seventeen (40%) patients developed a traumatic cataract, and 2 (4.7%) had dislocated lens fragments. Most common findings on presentation included vitreous hemorrhage (n = 30 [70%]) and hyphema (n = 28 [64%]). Two eyes (4.7%) had a retinal detachment at presentation, and 10 (23%) developed a retinal detachment during follow-up visits. Anatomical success was observed in 11 eyes (92%) with a retinal detachment. Three eyes (7.0%) became phthisical or prephthisical, and 1 was enucleated for severe pain. No eyes developed endophthalmitis or sympathetic ophthalmia. This is the largest compilation of nail gun-related open-globe injury reported to date. Posterior segment complications, noted in the majority of cases, likely contributed to the overall guarded visual outcomes. Preventative measures for eye protection should be strictly followed while using nail guns.

  13. Flexible intramedullary nailing for the treatment of unicameral bone cysts in long bones.

    PubMed

    Roposch, A; Saraph, V; Linhart, W E

    2000-10-01

    Unicameral bone cyst is characterized by its tenacity and risk of recurrence. Pathological fracture is common and is often the presenting symptom. The objective of the present study was to evaluate the results of flexible intramedullary nailing for the treatment of a unicameral bone cyst with or without a pathological fracture. Flexible intramedullary nailing for the treatment of a unicameral bone cyst was performed in thirty-two patients. Thirty of these patients presented with a pathological fracture; twenty-four were managed immediately with intramedullary nailing, and the other six had been managed conservatively at other clinics before they were referred to our department. The remaining two cysts were detected incidentally. The cyst was located in the humerus in twenty-one patients, in the femur in nine, and in the radius in two. The mean age of the patients at the time of surgery was 9.8 years, and the mean duration of follow-up was 53.7 months. Radiographic evaluation was performed according to the criteria of Capanna et al., and the cyst was classified as completely healed, healed with residual radiolucency (osteolysis), recurred, or having no response. The healing period ranged from three to 105 months. Fourteen cysts healed completely, and sixteen healed with residual radiolucent areas visible on radiographs. There was recurrence of two cysts that had healed with residual radiolucency. All of the cysts in the present study responded to treatment. A change of nails was necessary in nine patients, as the nails had become too short after bone growth. No major complications were observed. Flexible intramedullary nailing provides early stability, which allows early mobilization and thus obviates the need for a plaster cast and decreases the prevalence of the most common complication: a pathological fracture. This method of treatment also allows for an early return to normal activity.

  14. Dermoscopy of subungual haemorrhage: its usefulness in differential diagnosis from nail-unit melanoma.

    PubMed

    Mun, J-H; Kim, G-W; Jwa, S-W; Song, M; Kim, H-S; Ko, H-C; Kim, B-S; Kim, M-B

    2013-06-01

    Subungual haemorrhages are characterized by well-circumscribed dots or blotches with a red to red-black pigmentation, but some cases can be difficult to distinguish from subungual melanoma by the naked eye alone. Dermoscopy has proven to be a useful, noninvasive tool in the diagnosis of pigmented lesions in the nail; however, few dermoscopic studies of subungual haemorrhages have been reported. To investigate characteristic dermoscopic patterns of subungual haemorrhages, and to find distinctive features that can differentiate them from nail-unit melanomas. Patients with a confirmed diagnosis of either subungual haemorrhage or nail-unit melanoma at a tertiary university hospital were included in the study. Clinical features and dermoscopic patterns were evaluated. Sixty-four patients with a total of 90 lesions of subungual haemorrhage were enrolled in the study. The majority of cases (84%) showed combinations of more than one colour, while 16% had only one colour. The most common colour of the subungual haemorrhages was purple-black, in 37% of cases. A homogeneous pattern was observed in 92% of cases, globular patterns in 42% and streaks in 39%. Peripheral fading and periungual haemorrhages were found in 54% and 22% of cases, respectively. Destruction or dystrophy of the nail plate was observed in 16% of cases. In the 16 cases of nail-unit melanomas, Hutchinson sign, longitudinal irregular bands or lines, triangular shape of bands, vascular pattern, and ulcerations were found in 100%, 81%, 25%, 6% and 81% of cases, respectively. In contrast, these features were not found in subungual haemorrhages. Dermoscopy provides valuable information for the diagnosis of subungual haemorrhage and aids in the differential diagnosis from nail-unit melanoma. © 2013 The Authors. BJD © 2013 British Association of Dermatologists.

  15. Management of combined knee medial compartmental and patellofemoral osteoarthritis with lateral closing wedge osteotomy with anterior translation of the distal tibial fragment: Does the degree of anteriorization affect the functional outcome and posterior tibial slope?

    PubMed

    Sadek, Ahmed F; Osman, Mohammed K; Laklok, Mohamed A

    2016-10-01

    The aim of this study was to assess the effect of degree of anterior translation of the distal tibial fragment after lateral closing wedge high tibial osteotomy in patients having combined knee medial compartmental and patellofemoral osteoarthritis. A retrospective study was conducted on 64 patients who were operated on for combined knee medial compartmental and patellofemoral osteoarthritis, by lateral closing wedge high tibial osteotomy with anterior translation of the distal tibial fragment. They were divided into two groups; Group I comprising 32 patients (34 knees, mean age of 51.4±7years) whose degree of anterior translation was <1cm and Group II comprising 32 patients (33 knees, mean age of 52.2±8.3years) whose degree of anterior translation was >1.5cm. The final assessment was performed via: visual analog scale, postoperative Knee Society clinical rating system function score, active range of motion, time to union, degree of correction of mechanical axis, posterior tibial slope, and Insall-Salvati ratio. Group II patients exhibited statistically superior mean postoperative score and better return to their work than Group I (P=0.013, 0.076, respectively). Both groups showed statistically significant differences between the preoperative and postoperative evaluation parameters (P<0.001). The posterior tibial slope was decreased in both groups but with no significant difference (P=0.527). Lateral closing wedge high tibial osteotomy combined with anterior translation of the distal tibial fragment more than 1.5cm achieved significantly better postoperative functional knee score. Both groups exhibited comparatively decreased posterior tibial slope. Copyright © 2016 Elsevier B.V. All rights reserved.

  16. The stability of a hip fracture determines the fatigue of an intramedullary nail.

    PubMed

    Eberle, S; Bauer, C; Gerber, C; von Oldenburg, G; Augat, P

    2010-01-01

    The purpose of this study was to address the question of how the stability of a proximal hip fracture determines the fatigue and failure mechanism of an intramedullary implant. To answer this question, mechanical experiments and finite element simulations with two different loading scenarios were conducted. The two load scenarios differed in the mechanical support of the fracture by an artificial bone sleeve, representing the femoral head and neck. The experiments confirmed that an intramedullary nail fails at a lower load in an unstable fracture situation in the proximal femur than in a stable fracture. The nails with an unstable support failed at a load 28 per cent lower than the nails with a stable support by the femoral neck. Hence, the mechanical support of a fracture is crucial to the fatigue failure of an implant. The simulation showed why the fatigue fracture of the nail starts at the aperture of the lag screw. It is the location of the highest von Mises stress, which is the failure criterion for ductile materials.

  17. Er:YLF-laser microperforation of the nail plate for drug delivery

    NASA Astrophysics Data System (ADS)

    Belikov, Andrey V.; Skrypnik, Alexei V.; Sergeev, Andrey N.; Smirnov, Sergey N.; Tavalinskaya, Anastasia D.

    2018-04-01

    Laser microperforation of a human nail plate is an effective method to increase the speed of local drugs delivery in the treatment of nail diseases. In this paper we present the study results of the influence of spatial parameters of Er:YLFlaser- produced microhole array in human nail plate (the diameter of microholes and their packing density) on the rate (vsp) of 0.25 % water-alcohol solution of methylene blue penetration through a single microhole and on the time (Tmp) required for uniform distribution of this drug under the nail plate. In experiments, the diameter of microholes was 220 +/- 10 μm, 300 +/- 10 μm or 350 +/- 10 μm. The packing density for microholes of each of these diameters was 100 μholes/cm2, 400 μholes/cm2 and 950 μholes/cm2. It is shown that vsp is mainly determined by the microhole diameter, and the packing density does not have a significant influence on it. It was experimentally established that the rate vsp is maximal for microholes with 350 μm diameter at packing density of 950 μholes/cm2 and reaches a value of 6.3 μm/s, and the time Tmp is minimal and equal to 180 +/- 10 s at the same values of microhole diameter and packing density.

  18. Buyer beware: personnel selling nail guns know little about dangerous tools.

    PubMed

    Lipscomb, Hester J; Nolan, James; Patterson, Dennis; Fullen, Mark; Takacs, Brandon C; Pompeii, Lisa A

    2011-08-01

    Nail gun use is ubiquitous in wood frame construction. Accessibility and decreasing costs have extended associated occupational hazards to consumers. Compelling evidence documents decreased injury risk among trained users and those with tools with sequential triggers. To prevent inadvertent discharge of nails, this safer trigger requires the nose be depressed before the trigger is pulled to fire. The sequential trigger is not required by the Consumer Product Safety Commission (CPSC) or the Occupational Safety and Health Administration (OSHA) nor are there any guidelines for training. We collected data from personnel at 217 points of sale/rental of framing nail guns in four areas of the country. Sales personnel had little understanding of risks associated with use of framing nail guns. Individuals who had used the tool and those working in construction outlets were more likely to be knowledgeable; even so, less than half understood differences in trigger/actuation systems. Consumers, including contractors purchasing for workers, cannot count on receiving accurate information from sales personnel regarding risks associated with use of these tools. The attitudes and limited knowledge of some sales personnel regarding these potentially deadly tools likely contributes to a culture accepting of injury. The findings demonstrate how influences on the culture of construction are not limited to workers, employers, or the places construction gets done. Copyright © 2011 Wiley-Liss, Inc.

  19. Nail psoriasis in an adult successfully treated with a series of herbal skin care products family – a case report.

    PubMed

    Tirant, M; Hercogovấ, J; Fioranelli, M; Gianfaldoni, S; Chokoeva, A A; Tchernev, G; Wollina, U; Novotny, F; Roccia, M G; Maximov, G K; França, K; Lotti, T

    2016-01-01

    Psoriasis is a common chronic inflammatory dermatosis that causes significant distress and morbidity. Approximately 50% of patients with cutaneous psoriasis and 90% of patients with psoriatic arthritis demonstrate nail involvement of their psoriasis. Left untreated, nail psoriasis may progress to debilitating nail disease that leads to not only impairment of function but also on quality of life. We report the case of a 50-year-old male patient with recalcitrant nail dystrophies on the fingers since the age of 40, who responded successfully to Dr. Michaels® product family. The patient had a 35-year history of plaque psoriasis localised on the scalp, ears, groin, limbs, and trunk and with psoriatic arthritis. The nail symptoms consisted of onycholysis, onychomycosis, leukonychia, transverse grooves, nail plate crumbling and paronychia of the periungal skin. This case represents the efficacy and safety of the Dr. Michaels® (Soratinex® and Nailinex®) product family with successful resolution of nail dystrophies and surrounding paronychia with no reported adverse events.

  20. Treatment of shepherd’s crook deformity in patients with polyostotic fibrous dysplasia using a new type of custom made retrograde intramedullary nail: a technical note

    PubMed Central

    Hefti, F.; Donnan, L.; Krieg, A. H.

    2017-01-01

    Aims The severe form of coxa vara, the ‘shepherd’s crook deformity’, is always a consequence of a locally extensive form of polyostotic fibrous dysplasia (or McCune-Albright syndrome). Treatment of this deformity is a challenge. The soft bone does not tolerate any implant that depends on the stability of the cortical bone (like plates or external fixators). Intramedullary nails are the most appropriate implants for stabilisation, but if they are inserted from the greater trochanter, they cannot correct the varus deformity enough. Patients and Methods We have developed a special intramedullary nail that can be inserted from the osteotomy site and can be driven retrograde into the femoral neck in an appropriate valgus position. We have operated 15 legs in 13 patients. The average age at surgery was 14 years and 5 months (6 to 28.9). In all, 11 femora had been operated before (unsuccessfully) with various implants. Results The average follow-up was 54.2 months (7 to 132). The average correction of the neck/(distal) shaft angle was 57.5° (10° to 80°) ( = 72.8%). While pre-operatively none of the patients was able to walk without aid, at follow-up only one patient was unable to walk, three used the aid of crutches because of tibial lesions and one patient had an increased external rotation of the leg. At follow-up, most patients were free of pain. One implant broke and had to be replaced. Conclusion This new operative method offers the possibility of efficient correction and stabilisation of this severe and difficult deformation. PMID:28439311

  1. Flat midsubstance of the anterior cruciate ligament with tibial "C"-shaped insertion site.

    PubMed

    Siebold, Rainer; Schuhmacher, Peter; Fernandez, Francis; Śmigielski, Robert; Fink, Christian; Brehmer, Axel; Kirsch, Joachim

    2015-11-01

    This anatomical cadaver study was performed to investigate the flat appearance of the midsubstance shape of the anterior cruciate ligament (ACL) and its tibial "C"-shaped insertion site. The ACL midsubstance and the tibial ACL insertion were dissected in 20 cadaveric knees (n = 6 fresh frozen and n = 14 paraffined). Magnifying spectacles were used for all dissections. Morphometric measurements were performed using callipers and on digital photographs. In all specimens, the midsubstance of the ACL was flat with a mean width of 9.9 mm, thickness of 3.9 mm and cross-sectional area of 38.7 mm(2). The "direct" "C"-shaped tibial insertion runs from along the medial tibial spine to the anterior aspect of the lateral meniscus. The mean width (length) of the "C" was 12.6 mm, its thickness 3.3 mm and area 31.4 mm(2). The centre of the "C" was the bony insertion of the anterior root of the lateral meniscus overlayed by fat and crossed by the ACL. No posterolateral (PL) inserting ACL fibres were found. Together with the larger "indirect" part (area 79.6 mm(2)), the "direct" one formed a "duck-foot"-shaped footprint. The tibial ACL midsubstance and tibial "C"-shaped insertion are flat and are resembling a "ribbon". The centre of the "C" is the bony insertion of the anterior root of the lateral meniscus. There are no central or PL inserting ACL fibres. Anatomical ACL reconstruction may therefore require a flat graft and a "C"-shaped tibial footprint reconstruction with an anteromedial bone tunnel for single bundle and an additional posteromedial bone tunnel for double bundle.

  2. Subsurface Characterization using Geophysical Seismic Refraction Survey for Slope Stabilization Design with Soil Nailing

    NASA Astrophysics Data System (ADS)

    Ashraf Mohamad Ismail, Mohd; Ng, Soon Min; Hazreek Zainal Abidin, Mohd; Madun, Aziman

    2018-04-01

    The application of geophysical seismic refraction for slope stabilization design using soil nailing method was demonstrated in this study. The potential weak layer of the study area is first identify prior to determining the appropriate length and location of the soil nail. A total of 7 seismic refraction survey lines were conducted at the study area with standard procedures. The refraction data were then analyzed by using the Pickwin and Plotrefa computer software package to obtain the seismic velocity profiles distribution. These results were correlated with the complementary borehole data to interpret the subsurface profile of the study area. It has been identified that layer 1 to 3 is the potential weak zone susceptible to slope failure. Hence, soil nails should be installed to transfer the tensile load from the less stable layer 3 to the more stable layer 4. The soil-nail interaction will provide a reinforcing action to the soil mass thereby increasing the stability of the slope.

  3. Biomechanical assessment of composite versus metallic intramedullary nailing system in femoral shaft fractures: A finite element study.

    PubMed

    Samiezadeh, Saeid; Tavakkoli Avval, Pouria; Fawaz, Zouheir; Bougherara, Habiba

    2014-08-01

    Intramedullary nails are the primary choice for treating long bone fractures. However, complications following nail surgery including non-union, delayed union, and fracture of the bone or the implant still exist. Reducing nail stiffness while still maintaining sufficient stability seems to be the ideal solution to overcome the abovementioned complications. In this study, a new hybrid concept for nails made of carbon fibers/flax/epoxy was developed in order to reduce stress shielding. The mechanical performance of this new implant in terms of fracture stability and load sharing was assessed using a comprehensive non-linear FE model. This model considers several mechanical factors in nine fracture configurations at immediately post-operative, and in the healed bone stages. Post-operative results showed that the hybrid composite nail increases the average normal force at the fracture site by 319.23N (P<0.05), and the mean stress in the vicinity of fracture by 2.11MPa (P<0.05) at 45% gait cycle, while only 0.33mm and 0.39mm (P<0.05) increases in the fracture opening and the fragments' shear movement were observed. The healed bone results revealed that implantation of the titanium nail caused 20.2% reduction in bone stiffness, while the composite nail lowered the stiffness by 11.8% as compared to an intact femur. Our results suggest that the composite nail can provide a preferred mechanical environment for healing, particularly in transverse shaft fractures. This may help bioengineers better understand the biomechanics of fracture healing, and aid in the design of effective implants. Copyright © 2014. Published by Elsevier Ltd.

  4. Medial tibial pain. A prospective study of its cause among military recruits.

    PubMed

    Milgrom, C; Giladi, M; Stein, M; Kashtan, H; Margulies, J; Chisin, R; Steinberg, R; Swissa, A; Aharonson, Z

    1986-12-01

    In a prospective study of 295 infantry recruits during 14 weeks of basic training, 41% had medial tibial pain. Routine scintigraphic evaluation in cases of medial tibial bone pain showed that 63% had abnormalities. A stress fracture was found in 46%. Only two patients had periostitis. None had ischemic medial compartment syndrome. Physical examination could not differentiate between cases with medial tibial bone pain secondary to stress fractures and those with scintigraphically normal tibias. When both pain and swelling were localized in the middle one-third of the tibia, the lesion most likely proved to be a stress fracture.

  5. [Mobility of a polyethylene tibial insert in a mobile total knee prosthesis].

    PubMed

    Castel, E; Roger, B; Camproux, A; Saillant, G

    1999-03-01

    We have studied the mobility of a mobile tibial implant in total knee arthroplasty (TKA) by a radiographical evaluation. We analyzed mobility of the polyethylene tibial insert of 15 "G2S" TKA implanted for one year or more. We established a dynamic radiographical evaluation. We used 3 weight-bearing radiographs: AP in extension and two lateral (one in extension and one at 90 degrees of flexion), two AP with femoral internal and external rotation, 2 strict lateral X-rays in neutral rotation in antero-posterior replacement with a 25 kilograms strength Telos, and 2 AP in varus and valgus with Telos. Wilcoxon's test and Fisher's exact test were used for statistical evaluation. Our study demonstrated preservation of the polyethylene mobility in tibial TKA implant in all movements: in rotation, in antero-posterior translation with Telos, and even in antero-posterior translation during physiological condition with flexion-extension weight-bearing radiographs. Statistical tests were very significant. We noticed that flexion induced anterior translation of tibial polyethylene when PCL was preserved. This study answered to our question whether mobility of TKA tibial implant persists after implantation. This mobility should reduce loosening forces to the tibia and stress in the polyethylene component. Now we have to determine the amplitude of mobility required to reach this objective.

  6. The influence of nail blocking conditions in cattle femoral fractures.

    PubMed

    Paolucci, Leopoldo A; Las Casas, Estevam B; Faleiros, Rafael R; Paz, Cahuê F R; Rocha Junior, Sergio S

    2018-05-07

    To investigate the effect of different fixation strategies of the intramedullary interlocking nail (IIN) on the mechanical behavior of a polymeric implant applied for femoral fracture fixation in calves, and to evaluate the performance of a glass fiber-reinforced polymer applied in a bovine femoral fracture reduction system, five Holstein male animals with a mean weight (±SD) of 62.8 ± 20.4 kg and aged 74 ± 15 were used to generate biomechanical parameters for this study. Twelve models of the fractured bovine femur, simulating a simple oblique fracture, were developed for use during the simulations. The models were divided into three groups, with each group of four models being associated with a different fixation strategy. Models were used to simulate the loading conditions corresponding to a calf in the transition (decubitus position to static position) condition. The maximum stresses found in each set (bone/implant) were compared with the reference stresses of each nail material. Maximum implant stresses were found in the screws and at the interface between the screw and the nail. The performance of implants was influenced by the material and fixation strategy, which can be confirmed by the stress values found in the set. The analysis indicated that the composite nail is able to withstand the loading demands in all fixation strategies. The finite element analysis (FEA) demonstrated that all polymeric materials analyzed provided sufficient resistance to withstand the loading forces imposed to the femur when an adequate blocking strategy was applied. Copyright © 2018 Elsevier Ltd. All rights reserved.

  7. Longitudinal erythronychia: individual or multiple linear red bands of the nail plate: a review of clinical features and associated conditions.

    PubMed

    Cohen, Philip R

    2011-08-01

    Longitudinal erythronychia is a linear red band on the nail plate that originates at the proximal nail fold, traverses the lunula, and extends to the free edge of the nail plate. Longitudinal erythronychia is classified based upon the number of nails affected and the number of red streaks present on each nail as follows: type Ia (monodactylous - single band), type Ib (monodactylous - bifid bands), type IIa (polydactylous - single band), and type IIb (polydactylous - multiple bands). Associated morphologic findings that can be present at the distal tip of the nail with longitudinal erythronychia include fragility, onycholysis, splinter hemorrhage, splitting, subungual keratosis, thinning, and V-shaped nick. Some patients with longitudinal erythronychia seek medical evaluation because of pain in the associated distal digit; however, the linear red nail plate dyschromia is often asymptomatic and the individual is concerned about the cosmetic appearance or distal nail fragility. Longitudinal erythronychia can be a clinical manifestation of an underlying local or systemic condition. Benign tumors (glomus tumor, onychopapilloma, and warty dyskeratoma), malignant neoplasms (malignant melanoma and squamous cell carcinoma), and other conditions (hemiplegia and postsurgical scar) can be associated with monodactylous longitudinal erythronychia or it may be idiopathic or the initial stage of polydactylous longitudinal erythronychia-associated systemic conditions. Polydactylous longitudinal erythronychia is most commonly reported in patients with Darier disease (keratosis follicularis); other associated conditions include acantholytic dyskeratotic epidermal nevus, acantholytic epidermolysis bullosa, acrokeratosis verruciformis of Hopf, amyloidosis, graft-versus-host disease, lichen planus, and pseudobulbar syndrome. Polydactylous longitudinal erythronychia has also been observed as an idiopathic finding. Biopsy of the nail matrix and nail bed may be necessary to establish the

  8. Low concentrations of selenium and zinc in nails are associated with childhood asthma.

    PubMed

    Carneiro, Maria Fernanda Hornos; Rhoden, Claudia Ramos; Amantéa, Sérgio Luis; Barbosa, Fernando

    2011-12-01

    The purpose of this study was to investigate possible associations between Zn, Se, Cu, Mn, and Co concentrations in nails and asthma in a young population from a Southern Brazil city. Additionally, correlations between these chemical elements among asthmatic and non-asthmatic children were evaluated. Before nail collection (n = 165), children were asked to complete the International Study of Asthma and Allergies in Childhood questionnaire. The concentrations of trace elements were determined by inductively coupled plasma mass spectrometry. The chi-square test was used to evaluate the association between element concentrations in nails and the respiratory outcome. To evaluate correlations between the elements, we used the Spearman correlation test. For all tests, the significance level was set at 95% (P ≤ 0.05). Children included in the highest quartile of nail Se and Zn concentration presented a fivefold decrease in the prevalence ratio of asthma while children in the lowest Se range presented an almost 2.5-fold increase in the asthma prevalence ratio. There were weak to strong correlations between Cu vs. Zn, Cu vs. Co, Cu vs. Se, Zn vs. Se, Zn vs. Mn, and Mn vs. Co in both asthmatic and non-asthmatic children. Interestingly, non-asthmatics also presented correlations between Co vs. Se and Zn. Taken together, our results clearly demonstrated an association between concentrations of selenium and zinc and childhood asthma and the usefulness of nail as a noninvasive matrix to detect minerals imbalance in asthma patients.

  9. Density determination of nail polishes and paint chips using magnetic levitation

    NASA Astrophysics Data System (ADS)

    Huang, Peggy P.

    Trace evidence is often small, easily overlooked, and difficult to analyze. This study describes a nondestructive method to separate and accurately determine the density of trace evidence samples, specifically nail polish and paint chip using magnetic levitation (MagLev). By determining the levitation height of each sample in the MagLev device, the density of the sample is back extrapolated using a standard density bead linear regression line. The results show that MagLev distinguishes among eight clear nail polishes, including samples from the same manufacturer; separates select colored nail polishes from the same manufacturer; can determine the density range of household paint chips; and shows limited levitation for unknown paint chips. MagLev provides a simple, affordable, and nondestructive means of determining density. The addition of co-solutes to the paramagnetic solution to expand the density range may result in greater discriminatory power and separation and lead to further applications of this technique.

  10. Lasing in optimized two-dimensional iron-nail-shaped rod photonic crystals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kwon, Soon-Yong; Moon, Seul-Ki; Yang, Jin-Kyu, E-mail: jinkyuyang@kongju.ac.kr

    2016-03-15

    We demonstrated lasing at the Γ-point band-edge (BE) modes in optimized two-dimensional iron-nail-shaped rod photonic crystals by optical pulse pumping at room temperature. As the radius of the rod increased quadratically toward the edge of the pattern, the quality factor of the Γ-point BE mode increased up to three times, and the modal volume decreased to 56% compared with the values of the original Γ-point BE mode because of the reduction of the optical loss in the horizontal direction. Single-mode lasing from an optimized iron-nail-shaped rod array with an InGaAsP multiple quantum well embedded in the nail heads was observedmore » at a low threshold pump power of 160 μW. Real-image-based numerical simulations showed that the lasing actions originated from the optimized Γ-point BE mode and agreed well with the measurement results, including the lasing polarization, wavelength, and near-field image.« less

  11. Tibial and fibular nerves evaluation using intraoperative electromyography in rats.

    PubMed

    Nepomuceno, André Coelho; Politani, Elisa Landucci; Silva, Eduardo Guandelini da; Salomone, Raquel; Longo, Marco Vinicius Losso; Salles, Alessandra Grassi; Faria, José Carlos Marques de; Gemperli, Rolf

    2016-08-01

    To evaluate a new model of intraoperative electromyographic (EMG) assessment of the tibial and fibular nerves, and its respectives motor units in rats. Eight Wistar rats underwent intraoperative EMG on both hind limbs at two different moments: week 0 and week 12. Supramaximal electrical stimulation applied on sciatic nerve, and compound muscle action potential recorded on the gastrocnemius muscle (GM) and the extensor digitorum longus muscle (EDLM) through electrodes at specifics points. Motor function assessment was performaced through Walking Track Test. Exposing the muscles and nerves for examination did not alter tibial (p=0.918) or fibular (p=0.877) function between the evaluation moments. Electromyography of the GM, innervated by the tibial nerve, revealed similar amplitude (p=0.069) and latency (p=0.256) at week 0 and at 12 weeks, creating a standard of normality. Meanwhile, electromyography of the EDLM, innervated by the fibular nerve, showed significant differences between the amplitudes (p=0.003) and latencies (p=0.021) at the two different moments of observation. Intraoperative electromyography determined and quantified gastrocnemius muscle motor unit integrity, innervated by tibial nerve. Although this study was not useful to, objectively, assess extensor digitorum longus muscle motor unit, innervated by fibular nerve.

  12. Knee arthrodesis with an intramedullary nail: a retrospective study.

    PubMed

    De Vil, Jeroen; Almqvist, Karl Fredrik; Vanheeren, Philippe; Boone, Barbara; Verdonk, René

    2008-07-01

    A group of 19 patients who underwent knee arthrodesis with use of an intramedullary nail between 1996 and 2005, was studied. In the majority of patients knee arthrodesis was performed as a salvage procedure for the limb following an infected total knee arthroplasty. The outcome of the procedure was evaluated with radiographs, the SF-36 score and the Oxford 12-item knee score. The functional result of a successful arthrodesis was found to be comparable with that of a revised hinged total knee arthroplasty. Knee arthrodesis with an intramedullary nail allows weightbearing within 1 week and is accompanied by a high rate of pain relief. However, recurrence of infection is the most challenging problem.

  13. Efficacy and safety of Indigo naturalis extract in oil (Lindioil) in treating nail psoriasis: a randomized, observer-blind, vehicle-controlled trial.

    PubMed

    Lin, Yin-Ku; See, Lai-Chu; Huang, Yu-Huei; Chang, Ya-Ching; Tsou, Teng-Cheng; Lin, Tung-Yi; Lin, Na-Ling

    2014-06-15

    Treating nail psoriasis is notoriously difficult and lacks standardized therapeutic regimens. Indigo naturalis has been demonstrated to be safe and effective in treating skin psoriasis. This trial was conducted to evaluate the efficacy and safety of refined indigo naturalis extract in oil (Lindioil) in treating nail psoriasis. Thirty-one outpatients with symmetrically comparable psoriatic nails were enrolled. Lindioil (experimental group) or olive oil (control group) was applied topically to the same subjects' two bilaterally symmetrical psoriatic nails twice daily for the first 12 weeks and then subjects applied Lindioil to both hands for 12 additional weeks. Outcomes were measured using Nail Psoriasis Severity Index (NAPSI) for five nails on one hand and for the single most severely affected nail from either hand. The results show a reduction of NAPSI scores for the 12-week treatment for the Lindioil group (49.8% for one hand and 59.3% for single nail) was superior to the reduction in the scores for the control group (22.9%, 16.3%, respectively). There were no adverse events during the 24 weeks of treatment. This trial demonstrates that Lindioil is a novel, safe and effective therapy for treating nail psoriasis. Copyright © 2014 Elsevier GmbH. All rights reserved.

  14. Total knee arthroplasty after high tibial osteotomy. A comparison study in patients who had bilateral total knee replacement.

    PubMed

    Meding, J B; Keating, E M; Ritter, M A; Faris, P M

    2000-09-01

    The outcome of total knee replacement after high tibial osteotomy remains uncertain. We hypothesized that the results of total knee replacement with or without a previous high tibial osteotomy are similar. The results of a consecutive series of thirty-nine bilateral total knee arthroplasties performed with cement at an average of 8.7 years after unilateral high tibial osteotomy were reviewed. There were twenty-seven men and twelve women. Preoperatively, the knee scores according to the system of the Knee Society were similar for all of the knees; however, valgus alignment and patella infera were more common in the knees with a previous high tibial osteotomy. Bilateral total knee replacement was staged in seven patients and was simultaneous in thirty-two patients. The results of the total knee arthroplasties were retrospectively reviewed with respect to the knee and function scores according to the system of the Knee Society, the radiographic findings, and the complications. Intraoperatively, no notable differences were identified in the number of medial, lateral, or lateral patellar releases required. However, less lateral tibial bone was resected in the group with a previous high tibial osteotomy (average, 3.3 millimeters) than in the group without a high tibial osteotomy (average, 7.5 millimeters). The average duration of follow-up was 7.5 years (range, three to sixteen years) in the group with a previous high tibial osteotomy and 6.8 years (range, two to ten years) in the group without a high tibial osteotomy. At the time of the final follow-up, the knee and function scores were similar for the two groups (89.0 and 81.0 points, respectively, for the group with a previous high tibial osteotomy, and 89.6 and 83.9 points, respectively, for the group without a high tibial osteotomy). Although more knees were free of pain in the group without a previous high tibial osteotomy (thirty-six) than in the group with a previous osteotomy (thirty-three), this difference was

  15. Management of tibial fractures using a circular external fixator in two calves.

    PubMed

    Aithal, Hari Prasad; Kinjavdekar, Prakash; Amarpal; Pawde, Abhijit Motiram; Singh, Gaj Raj; Setia, Harish Chandra

    2010-07-01

    To report the repair of tibial diaphyseal fractures in 2 calves using a circular external skeletal fixator (CEF). Clinical report. Crossbred calves (n=2; age: 6 months; weight: 55 and 60 kg). Mid-diaphyseal tibial fractures were repaired by the use of a 4-ring CEF (made of aluminum rings with 2 mm K-wires) alone in 1 calf and in combination with hemicerclage wiring in 1 calf. Both calves had good weight bearing with moderate lameness postoperatively. Fracture healing occurred by day 60 in 1 calf and by day 30 in calf 2. The CEF was well maintained and tolerated by both calves through fracture healing. Joint mobility and limb usage improved gradually after CEF removal. CEF provided a stable fixation of tibial fractures and healing within 60 days and functional recovery within 90 days. CEF can be safely and successfully used for the management of selected tibial fractures in calves.

  16. Treatment of segmental tibial fractures with supercutaneous plating.

    PubMed

    He, Xianfeng; Zhang, Jingwei; Li, Ming; Yu, Yihui; Zhu, Limei

    2014-08-01

    Segmental tibial fractures usually follow a high-energy trauma and are often associated with many complications. The purpose of this report is to describe the authors' results in the treatment of segmental tibial fractures with supercutaneous locking plates used as external fixators. Between January 2009 and March 2012, a total of 20 patients underwent external plating (supercutaneous plating) of the segmental tibial fractures using a less-invasive stabilization system locking plate (Synthes, Paoli, Pennsylvania). Six fractures were closed and 14 were open (6 grade IIIa, 2 grade IIIb, 4 grade II, and 2 grade I, according to the Gustilo classification). When imaging studies confirmed bone union, the plates and screws were removed in the outpatient clinic. Average time of follow-up was 23 months (range, 12-47 months). All fractures achieved union. Median time to union was 19 weeks (range, 12-40 weeks) for the proximal fractures and 22 weeks (range, 12-42 weeks) for the distal fractures. Functional results were excellent in 17 patients and good in 3. Delayed union of the fracture occurred in 2 patients. All patients' radiographs showed normal alignment. No rotational deformities and leg shortening were seen. No incidences of deep infection or implant failures occurred. Minor screw tract infection occurred in 2 patients. A new 1-stage protocol using supercutaneous plating as a definitive fixator for segmental tibial fractures is less invasive, has a lower cost, and has a shorter hospitalization time. Surgeons can achieve good reduction, soft tissue reconstruction, stable fixation, and high union rates using supercutaneous plating. The current patients obtained excellent knee and ankle joint motion and good functional outcomes and had a comfortable clinical course. Copyright 2014, SLACK Incorporated.

  17. A novel method for assessing chronic cortisol concentrations in dogs using the nail as a source.

    PubMed

    Mack, Z; Fokidis, H B

    2017-04-01

    Cortisol, a glucocorticoid secreted in response to stress, is used to assess adrenal function and mental health in clinical settings. Current methods assess cortisol sources that reflect short-term secretion that can vary with current stress state. Here, we present a novel method for the extraction and quantification of cortisol from the dog nail using solid phase extraction coupled to enzyme-linked immunosorbent assay. Validation experiments demonstrated accuracy (r = 0.836, P < 0.001) precision (15.1% coefficients of variation), and repeatability (14.4% coefficients of variation) with this method. Furthermore, nail cortisol concentrations were positively correlated to an established hair cortisol method (r = 0.736, P < 0.001). Nail cortisol concentrations did not differ with dog sex, breed, age, or weights; however, sample size limitations may preclude statistical significance. Nail cortisol may provide information on cortisol secretion integrated over the time corresponding to nail growth and may be useful as a tool for diagnosing stress and adrenal disorders in dogs. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Tibial rotational osteotomy for idiopathic torsion. A comparison of the proximal and distal osteotomy levels.

    PubMed

    Krengel, W F; Staheli, L T

    1992-10-01

    A retrospective analysis was done of 52 rotational tibial osteotomies (RTOs) performed on 35 patients with severe idiopathic tibial torsion. Thirty-nine osteotomies were performed at the proximal or midtibial level. Thirteen were performed at the distal tibial level with a technique previously described by one of the authors. Serious complications occurred in five (13%) of the proximal and in none of the distal RTOs. For severe and persisting idiopathic tibial torsion, the authors recommend correction by RTO at the distal level. Proximal level osteotomy is indicated only when a varus or valgus deformity required concurrent correction.

  19. 77 FR 24462 - Certain Steel Nails From the People's Republic of China: Amended Final Results of the Second...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-24

    ... steel nails: (1) Non-collated (i.e., hand-driven or bulk), two-piece steel nails having plastic or steel...-collated (i.e., hand-driven or bulk), steel nails having a bright or galvanized finish, a smooth, barbed or... actual head diameter of 0.3375'' to 0.500'', inclusive; and (4) Non-collated (i.e., hand-driven or bulk...

  20. The transverse ligament as a landmark for tibial sagittal insertions of the anterior cruciate ligament: a cadaveric study.

    PubMed

    Kongcharoensombat, Wirat; Ochi, Mitsuo; Abouheif, Mohamed; Adachi, Nobuo; Ohkawa, Shingo; Kamei, Goki; Okuhara, Atushi; Shibuya, Hoyatoshi; Niimoto, Takuya; Nakasa, Tomoyuki; Nakamae, Atsuo; Deie, Masataka

    2011-10-01

    The purpose of this study was to determine the relation between the position of the transverse ligament, the anterior edge of the anterior cruciate ligament (ACL) tibial footprint, and the center of the ACL tibial insertion. We used arthroscopy for localization of the anatomic landmarks, followed by insertions of guide pins under direct visualization, and then the position of these guide pins was checked on plain lateral radiographs. The transverse ligament and the anterior aspect of the ACL tibial footprint were identified by arthroscopy in 20 unpaired cadaveric knees (10 left and 10 right). Guide pins were inserted with tibial ACL adapter drill guides under direct observation at the transverse ligament, the anterior aspect of the tibial footprint, and the center of tibial insertion of the ACL. Then, plain lateral radiographs of specimens were taken. The Amis and Jakob line was used to define the attachment of the ACL tibial insertion and the transverse ligament. A sagittal percentage of the location of the insertion point was determined and calculated from the anterior margin of the tibia in the anteroposterior direction. The transverse ligament averaged 21.20% ± 4.1%, the anterior edge of the ACL tibial insertion averaged 21.60% ± 4.0%, and the center of the ACL tibial insertion averaged 40.30% ± 4.8%. There were similar percent variations between the transverse ligament and the anterior edge of the ACL tibial insertion, with no significant difference between them (P = .38). Intraobserver and interobserver reliability was high, with small standard errors of measurement. This study shows that the transverse ligament coincides with the anterior edge of the ACL tibial footprint in the sagittal plane. The transverse ligament can be considered as a new landmark for tibial tunnel positioning during anatomic ACL reconstruction. Copyright © 2011 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.