Science.gov

Sample records for 1-10 kev energy

  1. Observations of proton spectra (1.0 less than or equal to proton energy less than or equal to 300 keV) and pitch angle distributions at the plasmapause

    NASA Technical Reports Server (NTRS)

    Williams, D. J.; Fritz, T. A.; Konradi, A.

    1972-01-01

    Detailed proton spectral and pitch angle distribution observations were obtained from two proton detectors and a fluxgate magnetometer flown on Small Scientific Satellite A (Explorer 45). The data of interest are from orbit 99 in-bound occurring on 17 December 1971, some 8 hours prior to the sudden commencement of a magnetic storm. The data are consistent with the initiation of ion cyclotron instability when certain requirements are met. These criteria are met initially at the altitude at which the sudden intensity decrease occurs. However, after the initiation of the instability, the linear theory is unable to explain the further evolution of intensities, pitch angle distributions, and energy spectra of the ring current particles.

  2. Monte Carlo simulation of 1-10-keV electron scattering in an aluminum target

    NASA Astrophysics Data System (ADS)

    Kotera, Masatoshi; Murata, Kenji; Nagami, Koichi

    1981-12-01

    New Monte Carlo simulations of electron scattering based on the single scattering model have been performed in the low-energy region for an aluminum target, where two basic equations are required, namely the elastic scattering cross section and the energy-loss rate. We investigated the screened Rutherford equation and the Mott equation for two different atomic potentials for the former, and the Rao Sahib-Wittry equation (the modified Bethe equation) for the latter. The validity of each model is discussed in a comparison between Monte Carlo results and experimental results such as the electron range, electron backscattering, and electron transmission which have been reported by various authors. Consequently, it was found that a combination of the Mott cross section and the Rao Sahib-Wittry equation showed the best accuracy. However, the accuracy of a previous model with the screened Rutherford equation is not as bad as aniticipated because of the higher accuracy of the Born approximation for light elements such as Al, compared to Au.

  3. Neutron fluence and energy reconstruction with the IRSN recoil detector μ-TPC at 27 keV, 144 keV and 565 keV

    SciTech Connect

    Maire, D.; Lebreton, L.; Richer, J.P.; Bosson, G.; Bourrion, O.; Guillaudin, O.; Riffard, Q.; Santos, D.

    2015-07-01

    The French Institute for Radioprotection and Nuclear Safety (IRSN), associated to the French Metrology Institute (LNE), is developing a time projection chamber using a Micromegas anode: μ-TPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize with a primary procedure the energy distribution of neutron fluence in the energy range 8 keV - 1 MeV. The time projection chambers are gaseous detectors, which are able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulated detector response. The μ-TPC is a new reliable detector which enables to measure energy distribution of the neutron fluence without deconvolution or neutron calibration contrary to usual gaseous counters. The μ-TPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27.2 keV, 144 keV and 565 keV are shown and compared to the complete detector simulation. This work shows the first direct

  4. Photovoltaic Energy Valuation Model v 1.0

    SciTech Connect

    Klise Jamie Johnson, Geoffrey T.

    2012-01-09

    Currently, there is a need identified by Kennecott Land, as well as others in the real estate, appraisal and building industry to come up with a tool that is simple to use and can accurately value the electricity produced by a solar photovoltaic system. In the appraisal industry, comparable properties are used to help in the valuation of a residential property. Absent a comparable feature such as photovoltaic panels on a neighboring property, it is difficult for appraisers to assign a value to that system. In many cases, photovoltaic systems are assigned a value of $0, which essentially ignores the value of energy being produced and being saved by the homeowner relative to the cost of energy they would otherwise have to purchase from the local utility. There are multiple programs that can calculate the value of the energy produced in terms of the payback period and desired internal rate of return, but none employ the concept of discounting the future value of the energy produced at any period in the expected lifetime of a photovoltaic energy system. By creating this spreadsheet, a necessary gap has been filled. It is the expectation that this product will be included in training programs aimed towards the local appraisal community in Salt Lake County, Utah as well as expand into training offered at the national level through the Appraisal Institute. This software product is an excel spreadsheet that is used to calculate the present value of future energy production for photovoltaic electricity generating systems on residential and commercial properties. Visual Basic (VB) code within the spreadsheet allows user data to be passed to the PVWatts System Advisor Model webservice (http://www.nrel.gov/rredc/pvwatts/) and back into the spreadsheet to estimate the annual solar energy production in Salt Lake County, Utah (as well as anywhere in the U.S.). VB is also used for a discount rate calculation and calls the most current Fannie Mae 30-Year Fixed Rate 60-day

  5. High resolution 17 keV to 75 keV backlighters for High Energy Density experiments

    SciTech Connect

    Park, H; Maddox, B R; Giraldez, E; Hatchett, S P; Hudson, L; Izumi, N; Key, M H; Pape, S L; MacKinnon, A J; MacPhee, A G; Patel, P K; Phillips, T W; Remington, B A; Seely, J F; Tommasini, R; Town, R; Workman, J

    2008-02-25

    We have developed 17 keV to 75 keV 1-dimensional and 2-dimensional high-resolution (< 10 {micro}m) radiography using high-intensity short pulse lasers. High energy K-{alpha} sources are created by fluorescence from hot electrons interacting in the target material after irradiation by lasers with intensity I{sub L} > 10{sup 17} W/cm{sup 2}. We have achieved high resolution point projection 1-dimensional and 2-dimensional radiography using micro-foil and micro-wire targets attached to low-Z substrate materials. The micro-wire size was 10 {micro}m x 10 {micro}m x 300 {micro}m on a 300 {micro}m x 300 {micro}m x 5 {micro}m CH substrate. The radiography performance was demonstrated using the Titan laser at LLNL. We observed that the resolution is dominated by the micro-wire target size and there is very little degradation from the plasma plume, implying that the high energy x-ray photons are generated mostly within the micro-wire volume. We also observe that there are enough K{alpha} photons created with a 300 J, 1-{omega}, 40 ps pulse laser from these small volume targets, and that the signal-to-noise ratio is sufficiently high, for single shot radiography experiments. This unique technique will be used on future high energy density (HED) experiments at the new Omega-EP, ZR and NIF facilities.

  6. Hospital Energy Benchmarking Guidance - Version 1.0

    SciTech Connect

    Singer, Brett C.

    2009-09-08

    This document describes an energy benchmarking framework for hospitals. The document is organized as follows. The introduction provides a brief primer on benchmarking and its application to hospitals. The next two sections discuss special considerations including the identification of normalizing factors. The presentation of metrics is preceded by a description of the overall framework and the rationale for the grouping of metrics. Following the presentation of metrics, a high-level protocol is provided. The next section presents draft benchmarks for some metrics; benchmarks are not available for many metrics owing to a lack of data. This document ends with a list of research needs for further development.

  7. Measurement of the x-ray mass energy-absorption coefficient of air using 3 keV to 10 keV synchrotron radiation.

    PubMed

    Büermann, L; Grosswendt, B; Kramer, H-M; Selbach, H-J; Gerlach, M; Hoffmann, M; Krumrey, M

    2006-10-21

    For the first time absolute photon mass energy-absorption coefficients of air in the energy range 3 keV to 10 keV have been measured with relative standard uncertainties less than 1%, significantly smaller than those of up to 5% assumed hitherto for calculated data. Monochromatized synchrotron radiation was used to measure both the total radiant energy by means of silicon photodiodes calibrated against a cryogenic radiometer and the fraction of radiant energy that is deposited in dry air by means of a free air ionization chamber. The measured ionization charge was converted into energy absorbed in air by calculated effective W values of photons as a function of their energy based on new measurements of the W values in dry air for electron kinetic energies between 1 keV and 7 keV, also presented in this work. The measured absorption coefficients were compared with state-of-the art calculations and found to agree within 0.7% with data calculated earlier by Hubbell at energies above 4 keV but were found to differ by values up to 2.1% at 10 keV from more recent calculations of Seltzer.

  8. High resolution spectrometer for extended x-ray absorption fine structure measurements in the 6 keV to 15 keV energy range

    NASA Astrophysics Data System (ADS)

    Seely, J. F.; Hudson, L. T.; Henins, Albert; Feldman, U.

    2016-11-01

    A Cauchois transmission-crystal spectrometer has been developed with high crystal resolving power in the 6 keV-15 keV energy range and sufficient sensitivity to record single-shot spectra from the Lawrence Livermore National Laboratory (LLNL) Titan laser and other comparable or more energetic lasers. The spectrometer capabilities were tested by recording the W L transitions from a laboratory source and the extended x-ray absorption fine structure (EXAFS) spectrum through a Cu foil.

  9. The energy spectrum of 662 keV photons in a water equivalent phantom

    NASA Astrophysics Data System (ADS)

    Akar Tarim, U.; Gurler, O.; Ozmutlu, E. N.; Yalcin, S.; Gundogdu, O.; Sharaf, J. M.; Bradley, D. A.

    2012-07-01

    Investigation is made on the energy spectrum of photons originating from interactions of 662 keV primary gamma-ray photons emitted by a point source positioned at the centre of a water equivalent solid phantom of dimensions 19 cm×19 cm×24 cm. Peaks resulting from total energy loss (photopeak) and multiple and back scattering have been observed using a 51 mm×51 mm NaI(Tl) detector; good agreement being found between the measured and simulated response functions. The energy spectrum of the gamma photons obtained through the Monte Carlo simulation reveals local maxima at about 100 keV and 210 keV, being also observed in the experimental response function. Such spectra can be used as a method of testing the water equivalence of solid phantom media before their use for dosimetry measurements.

  10. Experimental Determination of the HPGe Spectrometer Efficiency Calibration Curves for Various Sample Geometry for Gamma Energy from 50 keV to 2000 keV

    SciTech Connect

    Saat, Ahmad; Hamzah, Zaini; Yusop, Mohammad Fariz; Zainal, Muhd Amiruddin

    2010-07-07

    Detection efficiency of a gamma-ray spectrometry system is dependent upon among others, energy, sample and detector geometry, volume and density of the samples. In the present study the efficiency calibration curves of newly acquired (August 2008) HPGe gamma-ray spectrometry system was carried out for four sample container geometries, namely Marinelli beaker, disc, cylindrical beaker and vial, normally used for activity determination of gamma-ray from environmental samples. Calibration standards were prepared by using known amount of analytical grade uranium trioxide ore, homogenized in plain flour into the respective containers. The ore produces gamma-rays of energy ranging from 53 keV to 1001 keV. Analytical grade potassium chloride were prepared to determine detection efficiency of 1460 keV gamma-ray emitted by potassium isotope K-40. Plots of detection efficiency against gamma-ray energy for the four sample geometries were found to fit smoothly to a general form of {epsilon} = A{Epsilon}{sup a}+B{Epsilon}{sup b}, where {epsilon} is efficiency, {Epsilon} is energy in keV, A, B, a and b are constants that are dependent on the sample geometries. All calibration curves showed the presence of a ''knee'' at about 180 keV. Comparison between the four geometries showed that the efficiency of Marinelli beaker is higher than cylindrical beaker and vial, while cylindrical disk showed the lowest.

  11. The 93Zr(n,γ) reaction up to 8 keV neutron energy

    NASA Astrophysics Data System (ADS)

    Tagliente, G.; Milazzo, P. M.; Fujii, K.; Abbondanno, U.; Aerts, G.; Álvarez, H.; Alvarez-Velarde, F.; Andriamonje, S.; Andrzejewski, J.; Audouin, L.; Badurek, G.; Baumann, P.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Calviño, F.; Calviani, M.; Cano-Ott, D.; Capote, R.; Carrapiço, C.; Cennini, P.; Chepel, V.; Chiaveri, E.; Colonna, N.; Cortes, G.; Couture, A.; Dahlfors, M.; David, S.; Dillmann, I.; Domingo-Pardo, C.; Dridi, W.; Duran, I.; Eleftheriadis, C.; Embid-Segura, M.; Ferrari, A.; Ferreira-Marques, R.; Furman, W.; Goncalves, I.; Gonzalez-Romero, E.; Gramegna, F.; Guerrero, C.; Gunsing, F.; Haas, B.; Haight, R.; Heil, M.; Herrera-Martinez, A.; Jericha, E.; Käppeler, F.; Kadi, Y.; Karadimos, D.; Karamanis, D.; Kerveno, M.; Kossionides, E.; Krtička, M.; Lamboudis, C.; Leeb, H.; Lindote, A.; Lopes, I.; Lukic, S.; Marganiec, J.; Marrone, S.; Martínez, T.; Massimi, C.; Mastinu, P.; Mengoni, A.; Moreau, C.; Mosconi, M.; Neves, F.; Oberhummer, H.; O'Brien, S.; Papachristodoulou, C.; Papadopoulos, C.; Paradela, C.; Patronis, N.; Pavlik, A.; Pavlopoulos, P.; Perrot, L.; Pigni, M. T.; Plag, R.; Plompen, A.; Plukis, A.; Poch, A.; Praena, J.; Pretel, C.; Quesada, J.; Reifarth, R.; Rosetti, M.; Rubbia, C.; Rudolf, G.; Rullhusen, P.; Salgado, J.; Santos, C.; Sarchiapone, L.; Savvidis, I.; Stephan, C.; Tain, J. L.; Tassan-Got, L.; Tavora, L.; Terlizzi, R.; Vannini, G.; Vaz, P.; Ventura, A.; Villamarin, D.; Vincente, M. C.; Vlachoudis, V.; Vlastou, R.; Voss, F.; Walter, S.; Wiescher, M.; Wisshak, K.

    2013-01-01

    The (n,γ) reaction of the radioactive isotope 93Zr has been measured at the n_TOF high-resolution time-of-flight facility at CERN. Resonance parameters have been extracted in the neutron energy range up to 8 keV, yielding capture widths smaller (14%) than reported in an earlier experiment. These results are important for detailed nucleosynthesis calculations and for refined studies of waste transmutation concepts.

  12. Tuning of wettability of PANI-GNP composites using keV energy ions

    NASA Astrophysics Data System (ADS)

    Lakshmi, G. B. V. S.; Avasthi, D. K.

    2016-07-01

    Polyaniline nanofiber composites with various nanomaterials have several applications in electrochemical biosensors. The surface properties of these composites coated electrodes play crucial role in enzyme absorption and analyte detection process. In the present study, Polyaniline-Graphene nanopowder (PANI-GNP) composites were prepared by rapid-mixing polymerization method. The films were prepared on ITO coated glass substrates and irradiated with 42 keV He+ ions produced by indigenously fabricated accelerator at IUAC, New Delhi. The films were characterized before and after irradiation by SEM, Raman spectroscopy and contact angle measurements. The as-prepared films show superhydrophilic nature and after irradiation the films show highly hydrophobic nature with water contact angle (135°). The surface morphology was studied by SEM and structural changes were studied by Raman spectra. The surface morphological modifications induced by keV energy ions helps in tuning the wettability at different ion fluences.

  13. Auroral electrons of energy less than 1 keV observed at rocket altitudes.

    NASA Technical Reports Server (NTRS)

    Arnoldy, R. L.; Choy, L. W.

    1973-01-01

    Measurements of electrons of energy less than 1 keV in the auroral precipitation with detectors aboard three rocket flights are discussed. Detectors simultaneously measured the flux of electrons moving up and down the magnetic field lines. Electrons of energy less than a few hundred electron volts show directional intensities ranging from isotropic over the upper hemisphere, to field aligned into the atmosphere, to a net streaming out of the atmosphere. Cases of reflection coefficients greater than 1 for the few hundred electron volts and lower-energy electrons occur when measurements were made north of auroral forms. These electrons might represent the high-energy tail of the return Birkeland currents. The origin of the low-energy electrons is itself in question.

  14. Efficiency of Scintillator Materials in the Energy Range 8.0-32.0 keV

    SciTech Connect

    Kinney, J H; Haupt, D L

    2002-07-01

    X-ray microtomography requires the measurement of x-ray attenuation along ray paths through a specimen, and on the inversion of these data to obtain a spatially resolved mapping of the microstructure of the specimen. To do this efficiently, two-dimensional array detectors are often used to measure the transmitted x-rays by capturing and recording each x-ray incident on the detector. The highest resolution CT instruments perform this by converting the incident x-rays to visible light, and then focusing this light onto a charge-coupled-device (CCD) detector. The light output of the scintillator (photons per incident x-ray), the numerical aperture of the optical lens system, and the quantum efficiency of the CCD govern the efficiency of the detection process. Several years earlier, our group performed an investigation aimed at determining the best scintillator material for high-resolution synchrotron CT. The selection criteria included light output in the 8-32 keV energy range, the spatial resolution of the scintillator, the wavelength of the scintillation radiation, and the stability and ease of polishing of the scintillator. A list of the scintillators that we considered, with the exceptions of the more recently developed glass scintillators, is provided in Table 1. Among these scintillators, we concluded that single crystal cadmium tungstate was optimum; we have used this material in all subsequent synchrotron CT systems. Since this original study, several doped-glass scintillators have become available. The LSO (Lu orthosilicates) scintillators, developed for PET scanning, show considerable light output at high energy (energies above 500 keV). Theoretically, the light output of these scintillators should be twice that of the cadmium tungstate. The purpose of this study was to determine the efficiency of two such scintillators (LSO:Yt and IQI-401 high density terbium activated glass) in the energy range from 8-32 keV.

  15. High order reflectivity of graphite (HOPG) crystals for x ray energies up to 22 keV

    SciTech Connect

    Doeppner, T; Neumayer, P; Girard, F; Kugland, N L; Landen, O L; Niemann, C; Glenzer, S H

    2008-04-30

    We used Kr K{alpha} (12.6 keV) and Ag K{alpha} (22.1 keV) x-rays, produced by petawatt class laser pulses interacting with a Kr gas jet and a silver foil, to measure the integrated crystal reflectivity of flat Highly Oriented Pyrolytic Graphite (HOPG) up to fifth order. The reflectivity in fourth order is lower by a factor of 50 when compared to first order diffraction. In second order the integrated reflectivity decreases from 1.3 mrad at 12.6 keV to 0.5 mrad at 22.1 keV. The current study indicates that HOPG crystals are suitable for measuring scattering signals from high energy x ray sources (E {ge} 20 keV). These energies are required to penetrate through the high density plasma conditions encountered in inertial confinement fusion capsule implosions on the National Ignition Facility.

  16. Evaluation of Silicon Neutron Resonance Parameters in the Energy Range Thermal to 1800 keV

    SciTech Connect

    Derrien, H.

    2002-09-30

    The evaluation of the neutron cross sections of the three stable isotopes of silicon in the energy range thermal to 20 MeV was performed by Hetrick et al. for ENDF/B-VI (Evaluated Nuclear Data File). Resonance parameters were obtained in the energy range thermal to 1500 keV from a SAMMY analysis of the Oak Ridge National Laboratory experimental neutron transmission data. A new measurement of the capture cross section of natural silicon in the energy range 1 to 700 keV has recently been performed at the Oak Ridge Electron Linear Accelerator. Results of this measurement were used in a SAMMY reevaluation of the resonance parameters, allowing determination of the capture width of a large number of resonances. The experimental data base is described; properties of the resonance parameters are given. For the first time the direct neutron capture component has been taken into account from the calculation by Rauscher et al. in the energy range from thermal to 1 MeV. Results of benchmark calculations are also given. The new evaluation is available in the ENDF/B-VI format.

  17. Kinetic energy releases of small amino acids upon interaction with keV ions

    NASA Astrophysics Data System (ADS)

    Bari, S.; Alvarado, F.; Postma, J.; Sobocinski, P.; Hoekstra, R.; Schlathölter, T.

    2009-01-01

    In chromatin, DNA is tightly packed into one complex together with histone and non-histone proteins. These proteins are known to protect the DNA against indirect and to some extent even direct radiation damage. Radiation action upon amino acids is thus one of the primary steps in biological radiation action. In this paper we investigate the ionization and fragmentation of the gas-phase amino acids glycine, alanine and valine upon interaction with keV α-particles. High resolution coincidence time-of-flight mass spectrometry is used to determine the dominant fragmentation channels as well as fragment kinetic energies.

  18. Extension to Low Energies (<7keV) of High Pressure X-Ray Absorption Spectroscopy

    SciTech Connect

    Itie, J.-P.; Flank, A.-M.; Lagarde, P.; Idir, M.; Polian, A.; Couzinet, B.

    2007-01-19

    High pressure x-ray absorption has been performed down to 3.6 keV, thanks to the new LUCIA beamline (SLS, PSI) and to the use of perforated diamonds or Be gasket. Various experimental geometries are proposed, depending on the energy of the edge and on the concentration of the studied element. A few examples will be presented: BaTiO3 at the titanium K edge, Zn0.95 Mn0.05O at the manganese K edge, KCl at the potassium K edge.

  19. Global Deployment of Geothermal Energy Using a New Characterization in GCAM 1.0

    SciTech Connect

    Hannam, Phil; Kyle, G. Page; Smith, Steven J.

    2009-09-01

    This report documents modeling of geothermal energy in GCAM 1.0 (formerly MiniCAM) from FY2008 to FY2009, from the inputs to the U.S. Climate Change Technology Program report (Clarke et al., 2008a) to the present representation, which will be used in future work. To demonstrate the newest representation, we describe the procedure and outcome of six model runs that illustrate the potential role of geothermal energy in the U.S. and global regions through different futures climate policy, development and deployment of engineered, or enhanced, geothermal systems (EGS), and availability of other low-cost, low-carbon electricity generation technologies such as nuclear energy and carbon capture and storage (CCS).

  20. Gamma ray interaction studies of organic nonlinear optical materials in the energy range 122 keV-1330 keV

    NASA Astrophysics Data System (ADS)

    Awasarmol, V. V.; Gaikwad, D. K.; Raut, S. D.; Pawar, P. P.

    The mass attenuation coefficients (μm) for organic nonlinear optical materials measured at 122-1330 keV photon energies were investigated on the basis of mixture rule and compared with obtained values of WinXCOM program. It is observed that there is a good agreement between theoretical and experimental values of the samples. All samples were irradiated with six radioactive sources such as 57Co, 133Ba, 22Na, 137Cs, 54Mn and 60Co using transmission arrangement. Effective atomic and electron numbers or electron densities (Zeff and Neff), molar extinction coefficient (ε), mass energy absorption coefficient (μen/ρ) and effective atomic energy absorption cross section (σa,en) were determined experimentally and theoretically using the obtained μm values for investigated samples and graphs have been plotted. The graph shows that the variation of all samples decreases with increasing photon energy.

  1. Evaluation of silicon neutron resonance parameters in the thermal to 1800 keV energy range.

    PubMed

    Derrien, H; Leal, L C; Guber, K H; Larson, N M

    2005-01-01

    Because silicon is a major constituent of concrete and soil, neutron and gamma ray information on silicon is important for reactor shielding and criticality safety calculations. Therefore, much effort was put into the ENDF/B-VI evaluation for the three stable isotopes of silicon. The neutron capture cross section of natural silicon was recently measured at the Oak Ridge Electron Linear Accelerator (ORELA) in the energy range 1-700 keV. Using the ENDF/B-VI evaluation for initial values, a new evaluation of the resonance parameters was performed by adding the results of the ORELA capture measurements to the experimental database. The computer code SAMMY was used for the analysis of the experimental data; the new version of SAMMY allows accurate calculations of the self-shielding and multiple scattering effects in the capture measurements. The accuracy of the radiative capture widths of the resonances was improved by this analysis. Accurate values of the s-, p- and d-wave neutron strength functions were also obtained. Although the resonance capture component of the present evaluation is 2-3 times smaller than that in ENDF/B-VI, the total capture cross section is much larger, at least for energies >250 keV, because the direct capture component contributes values of the same order of magnitude as the resonance component. The direct component was not taken into account in the ENDF/B-VI evaluation and was calculated for the first time in the present evaluation.

  2. SURVIVAL DEPTH OF ORGANICS IN ICES UNDER LOW-ENERGY ELECTRON RADIATION ({<=}2 keV)

    SciTech Connect

    Barnett, Irene Li; Lignell, Antti; Gudipati, Murthy S.

    2012-03-01

    Icy surfaces in our solar system are continually modified and sputtered with electrons, ions, and photons from solar wind, cosmic rays, and local magnetospheres in the cases of Jovian and Saturnian satellites. In addition to their prevalence, electrons specifically are expected to be a principal radiolytic agent on these satellites. Among energetic particles (electrons and ions), electrons penetrate by far the deepest into the ice and could cause damage to organic material of possible prebiotic and even biological importance. To determine if organic matter could survive and be detected through remote sensing or in situ explorations on these surfaces, such as water ice-rich Europa, it is important to obtain accurate data quantifying electron-induced chemistry and damage depths of organics at varying incident electron energies. Experiments reported here address the quantification issue at lower electron energies (100 eV-2 keV) through rigorous laboratory data analysis obtained using a novel methodology. A polycyclic aromatic hydrocarbon molecule, pyrene, embedded in amorphous water ice films of controlled thicknesses served as an organic probe. UV-VIS spectroscopic measurements enabled quantitative assessment of organic matter survival depths in water ice. Eight ices of various thicknesses were studied to determine damage depths more accurately. The electron damage depths were found to be linear, approximately 110 nm keV{sup -1}, in the tested range which is noticeably higher than predictions by Monte Carlo simulations by up to 100%. We conclude that computational simulations underestimate electron damage depths in the energy region {<=}2 keV. If this trend holds at higher electron energies as well, present models utilizing radiation-induced organic chemistry in icy solar system bodies need to be revisited. For interstellar ices of a few micron thicknesses, we conclude that low-energy electrons generated through photoionization processes in the interstellar medium

  3. NEUTRON TOTAL CROSS SECTIONS OF 235U FROM TRANSMISSION MEASUREMENTS IN THE ENERGY RANGE 2 keV to 300 keV AND STATISTICAL MODEL ANALYSIS OF THE DATA

    SciTech Connect

    Derrien, H.

    2000-05-22

    The average {sup 235}U neutron total cross sections were obtained in the energy range 2 keV to 330 keV from high-resolution transmission measurements of a 0.033 atom/b sample. The experimental data were corrected for the contribution of isotope impurities and for resonance self-shielding effects in the sample. The results are in very good agreement with the experimental data of Poenitz et al. in the energy range 40 keV to 330 keV and are the only available accurate experimental data in the energy range 2 keV to 40 keV. ENDF/B-VI evaluated data are 1.7% larger. The SAMMY/FITACS code was used for a statistical model analysis of the total cross section, selected fission cross sections and {alpha} data in the energy range 2 keV to 200 keV. SAMMY/FITACS is an extended version of SAMMY which allows consistent analysis of the experimental data in the resolved and unresolved resonance region. The Reich-Moore resonance parameters were obtained from a SAMMY Bayesian fits of high resolution experimental neutron transmission and partial cross section data below 2.25 keV, and the corresponding average parameters and covariance data were used in the present work as input for the statistical model analysis of the high energy range of the experimental data. The result of the analysis shows that the average resonance parameters obtained from the analysis of the unresolved resonance region are consistent with those obtained in the resolved energy region. Another important result is that ENDF/B-VI capture cross section could be too small by more than 10% in the energy range 10 keV to 200 keV.

  4. Neutron Total Cross Sections of {sup 235}U From Transmission Measurements in the Energy Range 2 keV to 300 keV and Statistical Model Analysis of the Data

    SciTech Connect

    Derrien, H.; Harvey, J.A.; Larson, N.M.; Leal, L.C.; Wright, R.Q.

    2000-05-01

    The average {sup 235}U neutron total cross sections were obtained in the energy range 2 keV to 330 keV from high-resolution transmission measurements of a 0.033 atom/b sample.1 The experimental data were corrected for the contribution of isotope impurities and for resonance self-shielding effects in the sample. The results are in very good agreement with the experimental data of Poenitz et al.4 in the energy range 40 keV to 330 keV and are the only available accurate experimental data in the energy range 2 keV to 40 keV. ENDF/B-VI evaluated data are 1.7% larger. The SAMMY/FITACS code 2 was used for a statistical model analysis of the total cross section, selected fission cross sections and data in the energy range 2 keV to 200 keV. SAMMY/FITACS is an extended version of SAMMY which allows consistent analysis of the experimental data in the resolved and unresolved resonance region. The Reich-Moore resonance parameters were obtained 3 from a SAMMY Bayesian fits of high resolution experimental neutron transmission and partial cross section data below 2.25 keV, and the corresponding average parameters and covariance data were used in the present work as input for the statistical model analysis of the high energy range of the experimental data. The result of the analysis shows that the average resonance parameters obtained from the analysis of the unresolved resonance region are consistent with those obtained in the resolved energy region. Another important result is that ENDF/B-VI capture cross section could be too small by more than 10% in the energy range 10 keV to 200 keV.

  5. A comparative study of inelastic scattering models at energy levels ranging from 0.5 keV to 10 keV

    NASA Astrophysics Data System (ADS)

    Hu, Chia-Yu; Lin, Chun-Hung

    2017-03-01

    Six models, including a single-scattering model, four hybrid models, and one dielectric function model, were evaluated using Monte Carlo simulations for aluminum and copper at incident beam energies ranging from 0.5 keV to 10 keV. The inelastic mean free path, mean energy loss per unit path length, and backscattering coefficients obtained by these models are compared and discussed to understand the merits of the various models. ANOVA (analysis of variance) statistical models were used to quantify the effects of inelastic cross section and energy loss models on the basis of the simulated results deviation from the experimental data for the inelastic mean free path, the mean energy loss per unit path length, and the backscattering coefficient, as well as their correlations. This work in this study is believed to be the first application of ANOVA models towards evaluating inelastic electron beam scattering models. This approach is an improvement over the traditional approach which involves only visual estimation of the difference between the experimental data and simulated results. The data suggests that the optimization of the effective electron number per atom, binding energy, and cut-off energy of an inelastic model for different materials at different beam energies is more important than the selection of inelastic models for Monte Carlo electron scattering simulation. During the simulations, parameters in the equations should be tuned according to different materials for different beam energies rather than merely employing default parameters for an arbitrary material. Energy loss models and cross-section formulas are not the main factors influencing energy loss. Comparison of the deviation of the simulated results from the experimental data shows a significant correlation (p < 0.05) between the backscattering coefficient and energy loss per unit path length. The inclusion of backscattering electrons generated by both primary and secondary electrons for

  6. Monte Carlo calculations of energy deposition distributions of electrons below 20 keV in protein.

    PubMed

    Tan, Zhenyu; Liu, Wei

    2014-05-01

    The distributions of energy depositions of electrons in semi-infinite bulk protein and the radial dose distributions of point-isotropic mono-energetic electron sources [i.e., the so-called dose point kernel (DPK)] in protein have been systematically calculated in the energy range below 20 keV, based on Monte Carlo methods. The ranges of electrons have been evaluated by extrapolating two calculated distributions, respectively, and the evaluated ranges of electrons are compared with the electron mean path length in protein which has been calculated by using electron inelastic cross sections described in this work in the continuous-slowing-down approximation. It has been found that for a given energy, the electron mean path length is smaller than the electron range evaluated from DPK, but it is large compared to the electron range obtained from the energy deposition distributions of electrons in semi-infinite bulk protein. The energy dependences of the extrapolated electron ranges based on the two investigated distributions are given, respectively, in a power-law form. In addition, the DPK in protein has also been compared with that in liquid water. An evident difference between the two DPKs is observed. The calculations presented in this work may be useful in studies of radiation effects on proteins.

  7. High Spatial Resolution STXM at 6.2 keV Photon Energy

    SciTech Connect

    Vila-Comamala, Joan; Kewish, Cameron M.; Thibault, Pierre; Guzenko, Vitaliy; Gorelick, Sergey; Menzel, Andreas; Bunk, Oliver; David, Christian; Dierolf, Martin; Pfeiffer, Franz; Pilvi, Tero; Faerm, Elina; Ritala, Mikko

    2010-04-06

    We report on a zone-doubling technique that bypasses the electron-beam lithography limitations for the production of X-ray diffractive optics and enables the fabrication of Fresnel zone plates with smaller outermost zone widths than other well-established approaches. We have applied this method to manufacture hard X-ray Fresnel zone plates with outermost zone widths of 25 and 20 nm. These lenses have been tested in scanning transmission X-ray microscopy (STXM) at energies up to 6.2 keV, producing images of test structures that demonstrate a spatial resolution of 25 nm. High spatial resolution STXM images of several biological specimens have been acquired in transmission, dark-field and differential phase contrast modes.

  8. Electron capture in Ar++H2 collisions in the keV energy regime

    NASA Astrophysics Data System (ADS)

    Kimura, M.; Chapman, S.; Lane, N. F.

    1986-03-01

    Electron capture in Ar+( 2P)+H2(X 1Σg) collisions in the keV energy regime has been studied theoretically. The molecular-orbital expansion method was used within a semiclassical formalism and an electron translation factor correction was incorporated to the first order in the magnitude of the relative velocity V. The molecular wave function and eigenenergy were obtained using the diatoms-in-molecules (DIM) method. We have examined the effect of the orientation of the target H2 molecule on the electron-capture mechanism within the sudden adiabatic approximation. Since π symmetry arising from the p orbital of the Ar+ ion is involved in this system, a strong influence on the probability of the molecular orientation was found in all energies studied. As the collision energy increases, the Π-symmetry state in the initial channel becomes more important through the rotational coupling to the electron-capture mechanism, while at lower energies the Σ-symmetry state in the initial channel is the dominant source for the electron capture through strong radial coupling. Agreement of the present theory with measurements is good, but marked disagreement is seen with the atomic-orbital calculation.

  9. Observations of solar flare photon energy spectra from 20 keV to 7 MeV

    NASA Technical Reports Server (NTRS)

    Yoshimori, M.; Watanabe, H.; Nitta, N.

    1985-01-01

    Solar flare photon energy spectra in the 20 keV to 7 MeV range are derived from the Apr. 1, Apr. 4, apr. 27 and May 13, 1981 flares. The flares were observed with a hard X-ray and a gamma-ray spectrometers on board the Hinotori satellite. The results show that the spectral shape varies from flare to flare and the spectra harden in energies above about 400 keV. Effects of nuclear line emission on the continuum and of higher energy electron bremsstrahlung are considered to explain the spectral hardening.

  10. Stochastic spatial energy deposition profiles for MeV protons and keV electrons

    NASA Astrophysics Data System (ADS)

    Udalagama, C.; Bettiol, A. A.; Watt, F.

    2009-12-01

    With the rapid advances being made in novel high-energy ion-beam techniques such as proton beam writing, single-ion-event effects, ion-beam-radiation therapy, ion-induced fluorescence imaging, proton/ion microscopy, and ion-induced electron imaging, it is becoming increasingly important to understand the spatial energy-deposition profiles of energetic ions as they penetrate matter. In this work we present the results of comprehensive yet straightforward event-by-event Monte Carlo calculations that simulate ion/electron propagation and secondary electron ( δ ray) generation to yield spatial energy-deposition data. These calculations combine SRIM/TRIM features, EEDL97 data and volume-plasmon-localization models with a modified version of one of the newer δ ray generation models, namely, the Hansen-Kocbach-Stolterfoht. The development of the computer code DEEP (deposition of energy due to electrons and protons) offers a unique means of studying the energy-deposition/redistribution problem while still retaining the important stochastic nature inherent in these processes which cannot be achieved with analytical modeling. As an example of an application of DEEP we present results that compare the energy-deposition profiles of primary MeV protons and primary keV electrons in polymethymethacrylate. Such data are important when comparing proximity effects in the direct write lithography processes of proton-beam writing and electron-beam writing. Our calculations demonstrate that protons are able to maintain highly compact spatial energy-deposition profiles compared with electrons.

  11. DISPLACEMENT CASCADE SIMULATION IN TUNGSTEN UP TO 200 KEV OF DAMAGE ENERGY AT 300, 1025, AND 2050 K

    SciTech Connect

    Setyawan, Wahyu; Nandipati, Giridhar; Roche, Kenneth J.; Kurtz, Richard J.; Wirth, Brian D.

    2015-09-22

    We generated molecular dynamics database of primary defects that adequately covers the range of tungsten recoil energy imparted by 14-MeV neutrons. During this semi annual period, cascades at 150 and 200 keV at 300 and 1025 K were simulated. Overall, we included damage energy up to 200 keV at 300 and 1025 K, and up to 100 keV at 2050 K. We report the number of surviving Frenkel pairs (NF) and the size distribution of defect clusters. The slope of the NF curve versus cascade damage energy (EMD), on a log-log scale, changes at a transition energy (μ). For EMD > μ, the cascade forms interconnected damage regions that facilitate the formation of large clusters of defects. At 300 K and EMD = 200 keV, the largest size of interstitial cluster and vacancy cluster is 266 and 335, respectively. Similarly, at 1025 K and EMD = 200 keV, the largest size of interstitial cluster and vacancy cluster is 296 and 338, respectively. At 2050 K, large interstitial clusters also routinely form, but practically no large vacancy clusters do

  12. Imager of low energy neutral atoms (ILENA) - Imaging neutrals from the magnetosphere at energies below 20 keV

    NASA Technical Reports Server (NTRS)

    Herrero, Federico A.; Smith, Mark F.

    1992-01-01

    We describe a new imager suitable for measurements of magnetospheric neutrals with energies from about 100 eV to about 10 keV; an energy range adequate for imaging the plasmasheet neutral atoms out to about 10 R(E). The instrument, an outgrowth of a study of atom-surface collisions in support of satellite drag calculations, separates incident photons from neutral atoms by surface scattering and conversion of the neutrals to ions. Subsequently, the ions formed on the first surface are accelerated through a light rejection section which also disperses the ions according to energy. The dispersed ion beam is then allowed to impact a second surface where a start pulse is generated to obtain ion velocity and energy/charge. The second surface is chosen to give large secondary electron emission without regard to charge state of the particles reflected from it. The data supporting the proposed ILENA design is presented in the first part of the paper.

  13. Applications of “Tender” Energy (1-5 keV) X-ray Absorption Spectroscopy in Life Sciences

    SciTech Connect

    Northrup, Paul; Leri, Alessandra; Tappero, Ryan

    2016-02-15

    The “tender” energy range of 1 to 5 keV, between the energy ranges of most “hard” (>5 keV) and “soft” (<1 keV) synchrotron X-ray facilities, offers some unique opportunities for synchrotron-based X-ray absorption fine structure spectroscopy in life sciences. In particular the K absorption edges of Na through Ca offer opportunities to study local structure, speciation, and chemistry of many important biological compounds, structures and processes. This is an area of largely untapped science, in part due to a scarcity of optimized facilities. Such measurements also entail unique experimental challenges. Lastly, this brief review describes the technique, its experimental challenges, recent progress in development of microbeam measurement capabilities, and several highlights illustrating applications in life sciences.

  14. Applications of “Tender” Energy (1-5 keV) X-ray Absorption Spectroscopy in Life Sciences

    DOE PAGES

    Northrup, Paul; Leri, Alessandra; Tappero, Ryan

    2016-02-15

    The “tender” energy range of 1 to 5 keV, between the energy ranges of most “hard” (>5 keV) and “soft” (<1 keV) synchrotron X-ray facilities, offers some unique opportunities for synchrotron-based X-ray absorption fine structure spectroscopy in life sciences. In particular the K absorption edges of Na through Ca offer opportunities to study local structure, speciation, and chemistry of many important biological compounds, structures and processes. This is an area of largely untapped science, in part due to a scarcity of optimized facilities. Such measurements also entail unique experimental challenges. Lastly, this brief review describes the technique, its experimental challenges,more » recent progress in development of microbeam measurement capabilities, and several highlights illustrating applications in life sciences.« less

  15. Experimental investigation of ≈130 keV kinetic energy antiprotons annihilation on nuclei

    NASA Astrophysics Data System (ADS)

    Aghai-Khozani, H.; Barna, D.; Corradini, M.; Hayano, R.; Hori, M.; Kobayashi, T.; Leali, M.; Lodi-Rizzini, E.; Mascagna, V.; Prest, M.; Soter, A.; Todoroki, K.; Vallazza, E.; Venturelli, L.; Zurlo, N.

    2014-04-01

    The study of the antiproton ( bar {p}) annihilation cross section on nuclei at low energies (eV-MeV region) has implications for fundamental cosmology as well as for nuclear physics. Concerning the former, different models try to explain the matter/antimatter asymmetry in the universe assuming the existence of the so-called "islands" where antinucleon-nucleon annihilations occur in the border region (Cohen et al. Astrophys. J. 495, 539-549, 1998), while, from the nuclear physics point of view, the annihilation process is a valuable tool to evaluate the neutron/proton ratio in order to probe the external region of the nucleus (Gupta et al. Nucl. Phys. B 70(3), 414-424, 1974). The existing data of antinucleon-nucleon (or -nucleus) annihilation cross-sections are mainly confined to energies above ≈1 MeV, while the cross section measured at LEAR in the 80's-90's (mostly with light targets Agnello et al. Phys. Lett. B 256, 349-353, 1991; Bertin et al. Phys. Lett. B 369, 77-85, 1996; Bertin et al. Phys. Lett. B 414, 220-228, 1997; Zenoni et al. Phys. Lett. B 461, 405-412, 1999; Bianconi et al. Phys. Lett. B 481, 194-198, 2000; Bianconi et al. Phys. Lett. B 492, 254-258, 2000) showed an unexpected behaviour for energies below 1 MeV (Bianconi et al. Phys. Lett. B 483, 353-359, 2000; Bianconi et al. Phys. Rev. C 62, 014611-7, 2000; Batty et al. Nucl. Phys. A 689, 721-740, 2001). The results showed a saturation with the atomic mass number against the A 2/3 trend which is observed for higher energies (being A the target mass number). The ASACUSA collaboration at CERN recently measured antiproton annihilation cross section on different kinds of nuclei with a bar {p} kinetic energy of 5.3 MeV (Bianconi et al. Phys. Lett. B 704, 461-466, 2011; Corradini et al. Nucl. Instr. Methods A 711, 12-20, 2013). Such results proved compatibility with the black-disk model with the Coulomb correction. But till now experimental difficulties prevented the investigation at energies below ≈1

  16. R-Matrix Analysis of 238U High Resolution Neutron Transmissions and Capture Cross Sections in the Energy Range 0 keV to 20 keV

    SciTech Connect

    Derrien, Herve; Leal, Luiz C; Larson, Nancy M

    2009-01-01

    The neutron resonance parameters of 238U were obtained from a SAMMY analysis of high-resolution neutron transmission measurements and high-resolution capture cross section measurements performed at the Oak Ridge Electron Linear Accelerator (ORELA) in the years 1970-1990 and from more recent transmission and capture cross section measurements performed at the Geel Linear Accelerator (GELINA). Compared with previous evaluations, the energy range for this resonance analysis was extended from 10 to 20 keV, taking advantage of the high resolution of the most recent ORELA transmission measurements. The experimental database and the method of analysis are described in this report. The neutron transmissions and the capture cross sections calculated with the resonance parameters are compared with the experimental data. A description is given of the statistical properties of the resonance parameters and of the recommended values of the average parameters. The new evaluation results in a slight decrease of the effective capture resonance integral and improves the prediction of integral thermal benchmarks by 70 to 200 pcm.

  17. Studies on effective atomic numbers for photon energy absorption and electron density of some narcotic drugs in the energy range 1 keV-20 MeV

    NASA Astrophysics Data System (ADS)

    Gounhalli, Shivraj G.; Shantappa, Anil; Hanagodimath, S. M.

    2013-04-01

    Effective atomic numbers for photon energy absorption ZPEA,eff, photon interaction ZPI,eff and for electron density Nel, have been calculated by a direct method in the photon-energy region from 1 keV to 20 MeV for narcotic drugs, such as Heroin (H), Cocaine (CO), Caffeine (CA), Tetrahydrocannabinol (THC), Cannabinol (CBD), Tetrahydrocannabivarin (THCV). The ZPEA,eff, ZPI,eff and Nel values have been found to change with energy and composition of the narcotic drugs. The energy dependence ZPEA,eff, ZPI,eff and Nel is shown graphically. The maximum difference between the values of ZPEA,eff, and ZPI,eff occurs at 30 keV and the significant difference of 2 to 33% for the energy region 5-100 keV for all drugs. The reason for these differences is discussed.

  18. Energy Integration for 2050 - A Strategic Impact Model (2050 SIM), Version 1.0

    SciTech Connect

    Not Available

    2010-10-01

    The United States (U.S.) energy infrastructure is among the most reliable, accessible, and economic in the world. On the other hand, it is also excessively reliant on foreign energy sources, experiences high volatility in energy prices, does not always practice good stewardship of finite indigenous energy resources, and emits significant quantities of greenhouse gas. The U.S. Department of Energy is conducting research and development on advanced nuclear reactor concepts and technologies, including High Temperature Gas Reactor (HTGR) technologies, directed at helping the United States meet its current and future energy challenges. This report discusses the Draft Strategic Impact Model (SIM), an initial version of which was created during the later part of FY-2010. SIM was developed to analyze and depict the benefits of various energy sources in meeting the energy demand and to provide an overall system understanding of the tradeoffs between building and using HTGRs versus other existing technologies for providing energy (heat and electricity) to various energy-use sectors in the United States. This report also provides the assumptions used in the model, the rationale for the methodology, and the references for the source documentation and source data used in developing the SIM.

  19. Commercial Building Energy Asset Score System: Program Overview and Technical Protocol (Version 1.0)

    SciTech Connect

    Wang, Na; Gorrissen, Willy J.

    2013-01-11

    The U.S. Department of Energy (DOE) is developing a national voluntary energy asset score system that includes an energy asset score tool to help building owners evaluate their buildings with respect to the score system. The goal of the energy asset score system is to facilitate cost-effective investment in energy efficiency improvements of commercial buildings. The system will allow building owners and managers to compare their building infrastructure against peers and track building upgrade progress over time. The system can also help other building stakeholders (e.g., building operators, tenants, financiers, and appraisers) understand the relative efficiency of different buildings in a way that is independent from their operations and occupancy. This report outlines the technical protocol used to generate the energy asset score, explains the scoring methodology, and provides additional details regarding the energy asset score tool. This report also describes alternative methods that were considered prior to developing the current approach. Finally, this report describes a few features of the program where alternative approaches are still under evaluation.

  20. Mass attenuation coefficient of the Earth, Moon and Mars samples over 1keV-100GeV energy range.

    PubMed

    Camargo Moreira, Anderson; Roberto Appoloni, Carlos

    2006-09-01

    This work presents the calculation of the mass attenuation coefficient (micro) of lunar, Martian and terrestrial samples in function of the energy. WinXCOM software was employed to determine the micro values for the samples in the range from 1 keV to 100 GeV. The obtained values were practically the same for energies larger than 100 keV, but marked differences among the samples were observed for energies below 25 keV, which is the energy range of interest for the XRF system used in space probes.

  1. Sub-second variations of high energy ( 300 keV) hard X-ray emission from solar flares

    NASA Technical Reports Server (NTRS)

    Bai, Taeil

    1986-01-01

    Subsecond variations of hard X-ray emission from solar flares were first observed with a balloon-borne detector. With the launch of the Solar Maximum Mission (SMM), it is now well known that subsecond variations of hard X-ray emission occur quite frequently. Such rapid variations give constraints on the modeling of electron energization. Such rapid variations reported until now, however, were observed at relatively low energies. Fast mode data obtained by the Hard X-ray Burst Spectrometer (HXRBS) has time resolution of approximately 1 ms but has no energy resolution. Therefore, rapid fluctuations observed in the fast-mode HXRBS data are dominated by the low energy hard X-rays. It is of interest to know whether rapid fluctuations are observed in high-energy X-rays. The highest energy band at which subsecond variations were observed is 223 to 1057 keV. Subsecond variations observed with HXRBS at energies greater than 300 keV are reported, and the implications discussed.

  2. Performance of a medical imaging system for photons in the 60-140 keV energy range

    NASA Astrophysics Data System (ADS)

    Amendolia, S. R.; Bisogni, M. G.; Bottigli, U.; Ceccopieri, A.; Delogu, P.; Dipasquale, G.; Fantacci, M. E.; Maestro, P.; Marchi, A.; Marzulli, V. M.; Oliva, P.; Palmiero, R.; Pernigotti, E.; Rosso, V.; Stefanini, A.; Stumbo, S.

    2001-04-01

    We report the status of the art of a prototype based on a GaAs pixel detector bump-bonded to a dedicated VLSI chip to be possibly used for imaging in the nuclear medicine field. This device, with a 200 μm thick pixel matrix (64×64 square pixels, 170 μm side), has already been tested with very good results for digital mammography applications (mean energy 20 keV). For more energetic photons, as in nuclear medicine, a 600 μm thick detector has been chosen. Using radioactive sources ( 241Am, 60 keV and 99 mTc, 140 keV photons) we have measured the performance of our prototype in terms of charge collection and detection efficiency of the detector, discrimination capability of the electronics and imaging properties of the whole system. In particular, we have evaluated the spatial resolution properties measuring the Point Spread Function and the imaging capabilities using a home made thyroid phantom. We present also the comparison between these results and those obtained with a traditional gamma camera and the evaluation, made by both experimental measurements and software simulations, of the geometry related to the use of a collimator.

  3. DWBA analysis of {sup 12}C(d,p){sup 13}C cross section data below 300 keV deuteron energy

    SciTech Connect

    Naqvi, A.A.; Ayer, Z.; Ludwig, E. ||

    1994-12-31

    {sup 12}C(d,p){sup 13}T differential cross section data at 200, 220, 250, 280 and 300 keV deuteron energies has been analyzed using finite range DWBA codes PTOLEMY and TWOFNR. It was observed that shape and magnitude of the cross section data at 300, 280 keV energies can be fitted well but the shape of 250, 220 and 200 keV data cannot be fitted. However 250, 220 and 200 keV data shape can be fitted by changing the optical model parameters at each energy. This indicates a very strong energy dependence of the optical model parameters data of the entrance channel over such a small energy range which is not observed in the presently available elastic scattering data of the entrance channel.

  4. Water, Energy and Carbon Sequestration Model (WECSsim) v. 1.0

    SciTech Connect

    2011-11-14

    The national Water, Energy and Carbon Sequestration Simulation Model (WECSsim) is an analysis tool that can be used at the local, regional and national scale to address a potentially combined system using a coal or natural gas-fired power plant, a geologic carbon sequestration system in saline formations, and water extraction and treatment. With this combined system for geologic storage of CO2 in saline formations, the treated saline formation water could be used as cooling water in the power plant. The key areas addressed in this tool include applying a data reduction process to existing NatCarb saline formation data to select the most viable formations for CO2 injection, water withdrawal and treatment metrics, and developing a national model to address the multiple combinations of power plants and saline formations. This model can be utilized by decision makers to understand the economic benefits and tradeoffs of this combined system. WECSsim allows for sensitivity analyses for capital costs, variables costs, CO2 sequestration and water treatment systems’ costs. The main goal of the WECSsim model is to allow interested individuals or groups the ability to run custom power plant, CO2 sequestration and water use scenarios for different regions of the country and understand the associated economics, longevity and potential of the CO2 sequestration and water extraction systems.

  5. Fully relativistic rovibrational energies and spectroscopic constants of the lowest X:(1)0(+)g, A':(1)2( u ), A:(1)1 ( u ), B':(1)0(-)u and B:(1)0(+)u states of molecular chlorine.

    PubMed

    Machado, Daniel F S; Silva, Valter H C; Esteves, Cristiano S; Gargano, Ricardo; Macedo, Luiz G M; Mundim, Kleber C; de Oliveira, Heibbe C B

    2012-09-01

    The main goal of this paper is to present the rovibrational energies and spectroscopic constants of the Cl(2) molecular system in the relativistic states [Formula: see text], A':(1)2( u ), A:(1)1( u ), [Formula: see text] and [Formula: see text]. More precisely, we have evaluated the Cl(2) ω ( e ), ω ( e ) x ( e ), ω ( e ) y ( e ), α ( e ), γ ( e ) and B ( e ) rovibrational spectroscopic constants using two different procedures. The first was obtained by combining the rovibrational energies, calculated through solving Schrödinger's nuclear equation and the diatomic rovibrational energy equation. The second was obtained by using the Dunham method. The calculated properties are in good agreement with available experimental data.

  6. Improving the energy response of external beam therapy (EBT) GafChromic{sup TM} dosimetry films at low energies (≤100 keV)

    SciTech Connect

    Bekerat, H. Devic, S.; DeBlois, F.; Singh, K.; Sarfehnia, A.; Seuntjens, J.; Shih, Shelley; Yu, Xiang; Lewis, D.

    2014-02-15

    Purpose: Purpose of this work is to investigate the effects of varying the active layer composition of external beam therapy (EBT) GafChromic{sup TM} films on the energy dependence of the film, as well as try to develop a new prototype with more uniform energy response at low photon energies (⩽100 keV). Methods: First, the overall energy response (S{sub AD,} {sub W}(Q)) of different commercial EBT type film models that represent the three different generations produced to date, i.e., EBT, EBT2, and EBT3, was investigated. Pieces of each film model were irradiated to a fixed dose of 2 Gy to water for a wide range of beam qualities and the corresponding S{sub AD,} {sub W}(Q) was measured using a flatbed document scanner. Furthermore, the DOSRZnrc Monte Carlo code was used to determine the absorbed dose to water energy dependence of the film, f(Q). Moreover, the intrinsic energy dependence, k{sub bq}(Q), for each film model was evaluated using the corresponding S{sub AD,} {sub W}(Q) and f(Q). In the second part of this study, the authors investigated the effects of changing the chemical composition of the active layer on S{sub AD,} {sub W}(Q). Finally, based on these results, the film manufacturer fabricated several film prototypes and the authors evaluated their S{sub AD,} {sub W}(Q). Results: The commercial EBT film model shows an under response at all energies below 100 keV reaching 39% ± 4% at about 20 keV. The commercial EBT2 and EBT3 film models show an under response of about 27% ± 4% at 20 keV and an over response of about 16% ± 4% at 40 keV.S{sub AD,} {sub W}(Q) of the three commercial film models at low energies show strong correlation with the corresponding f{sup −1}(Q) curves. The commercial EBT3 model with 4% Cl in the active layer shows under response of 22% ± 4% at 20 keV and 6% ± 4% at about 40 keV. However, increasing the mass percent of chlorine makes the film more hygroscopic which may affect the stability of the film's readout. The

  7. Absolute Calibration of Image Plate for electrons at energy between 100 keV and 4 MeV

    SciTech Connect

    Chen, H; Back, N L; Eder, D C; Ping, Y; Song, P M; Throop, A

    2007-12-10

    The authors measured the absolute response of image plate (Fuji BAS SR2040) for electrons at energies between 100 keV to 4 MeV using an electron spectrometer. The electron source was produced from a short pulse laser irradiated on the solid density targets. This paper presents the calibration results of image plate Photon Stimulated Luminescence PSL per electrons at this energy range. The Monte Carlo radiation transport code MCNPX results are also presented for three representative incident angles onto the image plates and corresponding electron energies depositions at these angles. These provide a complete set of tools that allows extraction of the absolute calibration to other spectrometer setting at this electron energy range.

  8. Electron-capture collisions at keV energies of multiply charged ions of carbon and argon with molecular deuterium

    SciTech Connect

    Bliman, S.; Aubert, J.; Geller, R.; Jacquot, B.; Van Houtte, D.

    1981-04-01

    Single- and double-electron-capture cross sections have been measured for C/sup q/+ with initial charges 2 < or = q < or = 6 and for Ar/sup q/+ with initial charges 2 < or = q < or = 12 incident on molecular deuterium gas targets. The cross sections show little dependence on the incident-ion energy for the range studied 2q to 10q keV. The single-electron-capture cross sections do not vary monotonically with the initial charge, but show an oscillation about a mean curve, reflecting the projectile electronic structure.

  9. Results of total cross section measurements for 197Au in the neutron energy region from 4 to 108 keV at GELINA

    NASA Astrophysics Data System (ADS)

    Sirakov, I.; Becker, B.; Capote, R.; Dupont, E.; Kopecky, S.; Massimi, C.; Schillebeeckx, P.

    2013-11-01

    Transmission measurements have been performed to determine the total cross section for neutron-induced reactions with 197Au in the energy region from 4keV to 108keV. The experiments were carried out at a 50m measurement station of the time-of-flight facility GELINA using a 6Li glass scintillator. The average total cross section as a function of neutron energy was derived after correcting the observed average transmission for cross section fluctuations due to resonance structures. The results have been compared with literature data and with the total cross section resulting from a dispersive coupled-channel optical model potential. The neutron strength function for s -wave neutrons and an orbital-independent scattering radius, together with their covariance matrix, have been derived in the neutron energy region between 4keV and 108keV through a parameterization of the total cross section based on a nuclear reaction theory.

  10. Energy response of GR-200A thermoluminescence dosemeters to 60Co and to monoenergetic synchrotron radiation in the energy range 28-40 keV.

    PubMed

    Emiro, F; Di Lillo, F; Mettivier, G; Fedon, C; Longo, R; Tromba, G; Russo, P

    2016-01-01

    The response of LiF:Mg,Cu,P thermoluminescence dosemeters (type GR-200A) to monoenergetic radiation of energy 28, 35, 38 and 40 keV was evaluated with respect to irradiation with a calibrated (60)Co gamma-ray source. High-precision measurements of the relative air kerma response performed at the SYRMEP beamline of the ELETTRA synchrotron radiation facility (Trieste, Italy) showed a significant deviation of the average response to low-energy X-rays from that to (60)Co, with an over-response from 6 % (at 28 keV) to 22 % (at 40 keV). These data are not consistent with literature data for these dosemeters, where model predictions gave deviation from unity of the relative air kerma response of about 10 %. The authors conclude for the need of additional determinations of the low-energy relative response of GR-200A dosemeters, covering a wider range of monoenergetic energies sampled at a fine energy step, as planned in future experiments by their group at the ELETTRA facility.

  11. Cross sections for ionization of tetrahydrofuran by protons at energies between 300 and 3000 keV

    NASA Astrophysics Data System (ADS)

    Wang, Mingjie; Rudek, Benedikt; Bennett, Daniel; de Vera, Pablo; Bug, Marion; Buhr, Ticia; Baek, Woon Yong; Hilgers, Gerhard; Rabus, Hans

    2016-05-01

    Double-differential cross sections for ionization of tetrahydrofuran by protons with energies from 300 to 3000 keV were measured at the Physikalisch-Technische Bundesanstalt ion accelerator facility. The electrons emitted at angles between 15∘ and 150∘ relative to the ion-beam direction were detected with an electrostatic hemispherical electron spectrometer. Single-differential and total ionization cross sections have been derived by integration. The experimental results are compared to the semiempirical Hansen-Kocbach-Stolterfoht model as well as to the recently reported method based on the dielectric formalism. The comparison to the latter showed good agreement with experimental data in a broad range of emission angles and energies of secondary electrons. The scaling property of ionization cross sections for tetrahydrofuran was also investigated. Compared to molecules of different size, the ionization cross sections of tetrahydrofuran were found to scale with the number of valence electrons at large impact parameters.

  12. SOLEX: a tunable monochromatic X-ray source in the 1-20 keV energy range for metrology

    NASA Astrophysics Data System (ADS)

    Bonnelle, C.; Jonnard, P.; André, J.-M.; Avila, A.; Laporte, D.; Ringuenet, H.; Lépy, M. C.; Plagnard, J.; Ferreux, L.; Protas, J. C.

    2004-01-01

    A tunable monochromatic X-ray source covering the 1-20 keV energy range is described. The initial X-ray beam is obtained from a dedicated windowless X-ray tube. The energy selection is performed through a cylindrically bent crystal, used either in the reflection (Johann geometry) or in the transmission (Cauchois geometry) mode, by rotating the crystal holder by a 90° angle. Contrary to conventional geometries where the X-ray tube is fixed, here the direction of the exit beam impinging the X-ray detector is fixed. This setup is shown to be useful for various studies: high-resolution spectrometry, characterization of the response function and the efficiency of detectors and optical components, determination of transmission characteristics of different materials. Observations of the Lα line and Kα doublet from a copper anode are presented, that demonstrate the performance of this new setup.

  13. Nuclear and electronic energy loss by 1 keV to 60 keV ions in silicon : comparison of measurement to SRIM

    SciTech Connect

    Funsten, H. O.; Harper, R. W.; Ritzau, S. M.; Korde, R.

    2003-01-01

    Comparison of TRIM simulations with measurements of the energy lost to electronic and nuclear stopping processes using 1 00% internal carrier collection efficiency silicon photodiodes shows a large, systematic overestimation by TRIM of electronic energy loss.

  14. Simulations of Microchannel Plate Sensitivity to <20 keV X-rays as a Function of Energy and Incident Angle

    SciTech Connect

    Kruschwitz, Craig; Wu, M.; Rochau, G. A.

    2013-06-13

    We present results of Monte Carlo simulations of microchannel plate (MCP) response to x-rays in the 250 eV to 20 keV energy range as a function of both x-ray energy and impact angle. The model is based on the model presented in Rochau et al. (2006). However, while the Rochau et al. (2006) model was two-dimensional, and their results only went to 5 keV, our results have been expanded to 20 keV, and our model has been incorporated into a three-dimensional Monte Carlo MCP model that we have developed over the past several years (Kruschwitz et al. 2011). X-ray penetration through multiple MCP pore walls is increasingly important above 5 keV. The effect of x-ray penetration through multiple pores on MCP performance was studied and is presented.

  15. Energy deposition in ultrathin extreme ultraviolet resist films: extreme ultraviolet photons and keV electrons

    NASA Astrophysics Data System (ADS)

    Kyser, David F.; Eib, Nicholas K.; Ritchie, Nicholas W. M.

    2016-07-01

    The absorbed energy density (eV/cm3) deposited by extreme ultraviolet (EUV) photons and electron beam (EB) high-keV electrons is proposed as a metric for characterizing the sensitivity of EUV resist films. Simulations of energy deposition are used to calculate the energy density as a function of the incident aerial flux (EUV: mJ/cm2, EB: μC/cm2). Monte Carlo calculations for electron exposure are utilized, and a Lambert-Beer model for EUV absorption. The ratio of electron flux to photon flux which results in equivalent energy density is calculated for a typical organic chemically amplified resist film and a typical inorganic metal-oxide film. This ratio can be used to screen EUV resist materials with EB measurements and accelerate advances in EUV resist systems.

  16. (239)Pu neutron resonance parameters revisited and covariance matrix in the neutron energy range from thermal to 2.5 keV

    SciTech Connect

    Derrien, Herve; Leal, Luiz C; Larson, Nancy M

    2008-01-01

    To obtain the resonance parameters in a single energy range up to 2.5 keV neutron energy and the corresponding covariance matrix, a reevaluation of 239Pu was performed with the analysis code SAMMY. The most recent experimental data were analyzed in the energy range thermal to 2.5 keV. The experimental data were renormalized, aligned on a common energy scale, and corrected for residual background. Average neutron transmission and cross sections calculated with the new resonance parameters were compared to the corresponding experimental data and to ENDF/B-VI.

  17. Determination of energy loss of 1200 keV deuterons along axial and planar channels of Si

    NASA Astrophysics Data System (ADS)

    Shafiei, S.; Lamehi-Rachti, M.

    2015-02-01

    In this paper, the energy loss of 1200 keV deuterons along the <1 0 0> and <1 1 0> axes as well as the {1 0 0} and {1 1 0} planes of Si were determined by the simulation of the channeling Rutherford backscattering spectra. The simulation was done by taking two considerations into account: (i) a minimum random component of the beam which enters the sample because of the scattering ions from the surface, (ii) the dechanneling starts at greater penetration depths, xDech. Moreover, it was assumed that the dechanneling follows a Gompertz type sigmoidal function with two parameters k and xc which present the dechanneling rate and range, respectively. The best simulation parameters, penetration depth at which the dechanneling starts, energy loss and dechanneling rate and range, were chosen by using the Levenberg-Marquardt algorithm. The experimental results are well reproduced by this simulation. The ratio of channeling energy loss to the random is changed from 0.63 ± 0.02 along the <1 1 0> axial channel to the 0.91 ± 0.02 along the {1 0 0} planar direction. The differences in the energy loss and the dechanneling process along the axial and planar channels are attributed to the potential barrier and the fractional area of each channel blocked by atoms. The ratio of channeling to random energy loss of deuterons along the <1 0 0> axial direction is in agreement with another reference.

  18. Measurement of Lα and Lβ1,3,4 fluorescence cross sections of La, Ce, Pr and Nd induced by photons of energies between 7.01 keV and 8.75 keV

    NASA Astrophysics Data System (ADS)

    Reyes-Herrera, J.; Miranda, J.

    2016-06-01

    This study presents measurement results of x-ray production cross sections of Lα and Lβ1,3,4 emitted by four lanthanoid elements (La, Ce, Pr and Nd), after irradiation with Kα and Kβ X rays of the elements Co, Ni, Cu, and Zn (covering energies between 7.01 keV and 8.75 keV). Primary x-rays were induced in turn by the irradiation of thick targets of these elements with a beam of x-rays produced by a tube with an Rh anode, operating at 50 kV and 850 μA. The experimental results are compared with theoretical cross sections predicted using known tabulations of photoelectric cross sections. Dirac-Hartree-Slater (DHS) atomic parameters were used for these calculations. An acceptable match between experiment and both sets of tabulated data is found.

  19. Dosimetric properties of high energy current (HEC) detector in keV x-ray beams

    NASA Astrophysics Data System (ADS)

    Zygmanski, Piotr; Shrestha, Suman; Elshahat, Bassem; Karellas, Andrew; Sajo, Erno

    2015-04-01

    We introduce a new x-ray radiation detector. The detector employs high-energy current (HEC) formed by secondary electrons consisting predominantly of photoelectrons and Auger electrons, to directly convert x-ray energy to detector signal without externally applied power and without amplification. The HEC detector is a multilayer structure composed of thin conducting layers separated by dielectric layers with an overall thickness of less than a millimeter. It can be cut to any size and shape, formed into curvilinear surfaces, and thus can be designed for a variety of QA applications. We present basic dosimetric properties of the detector as function of x-ray energy, depth in the medium, area and aspect ratio of the detector, as well as other parameters. The prototype detectors show similar dosimetric properties to those of a thimble ionization chamber, which operates at high voltage. The initial results obtained for kilovoltage x-rays merit further research and development towards specific medical applications.

  20. The formation of nanopores in metal materials after irradiation by beams of Ar+ with energy of 30 keV

    NASA Astrophysics Data System (ADS)

    Ivchenko, V. A.

    2017-01-01

    In this paper are the results of direction observations of nanopores in the subsurface volume of metals materials Pt and Pd(CuAg) using field-ion microscopy (FIM). Radiation of tip specimens was carried out with ions having an energy ∼ 25-30 keV in the fluency range of 1016 ‑ 1018 ions/cm2, the current density lying within 150– 340 µA/cm2. Nanopores have been observed immediately after removal of the first atomic layers from the irradiated surface. It was established that, the threshold for ion-implanted platinum corresponds to fluence F = 1017 ions/cm2. For Pd(CuAg) it was revealed that nanopores have been down to 80 nm deep with current density 340 µA/cm2. Their dimensions and volume fractions were determined. The obtained results can be used for prediction of radiation stability of materials based on fcc metals.

  1. Sustainable Energy Solutions Task 1.0: Networked Monitoring and Control of Small Interconnected Wind Energy Systems

    SciTech Connect

    edu, Janet. twomey@wichita.

    2010-04-30

    This report presents accomplishments, results, and future work for one task of five in the Wichita State University Sustainable Energy Solutions Project: To develop a scale model laboratory distribution system for research into questions that arise from networked control and monitoring of low-wind energy systems connected to the AC distribution system. The lab models developed under this task are located in the Electric Power Quality Lab in the Engineering Research Building on the Wichita State University campus. The lab system consists of four parts: 1. A doubly-fed induction generator 2. A wind turbine emulator 3. A solar photovoltaic emulator, with battery energy storage 4. Distribution transformers, lines, and other components, and wireless and wired communications and control These lab elements will be interconnected and will function together to form a complete testbed for distributed resource monitoring and control strategies and smart grid applications testing. Development of the lab system will continue beyond this project.

  2. Photon interaction study of organic nonlinear optical materials in the energy range 122-1330 keV

    NASA Astrophysics Data System (ADS)

    Awasarmol, Vishal V.; Gaikwad, Dhammajyot K.; Raut, Siddheshwar D.; Pawar, Pravina P.

    2017-01-01

    In the present study, the mass attenuation coefficient (μm) of six organic nonlinear optical materials has been calculated in the energy range 122-1330 keV and compared with the obtained values from the WinXCOM program. It is found that there is a good agreement between theoretical and experimental values (<3%). The linear attenuation coefficients (μ) total atomic cross section (σt, a), and total electronic cross section (σt, el) have also been calculated from the obtained μm values and their variations with photon energy have been plotted. From the present work, it is observed that the variation of obtained values of μm, μ, σt, a, and σt, el strongly depends on the photon energy and decreases or increases due to chemical composition and density of the sample. All the samples have been studied extensively using transmission method with a view to utilize the material for radiation dosimetry. Investigated samples are good material for radiation dosimetry due their low effective atomic number. The mass attenuation coefficient (μm), linear attenuation coefficients (μ), total atomic cross section (σt, a), total electronic cross section (σt, el), effective atomic numbers (Zeff), molar extinction coefficient (ε), mass energy absorption coefficient (μen/ρ) and effective atomic energy absorption cross section (σa, en) of all sample materials have been carried out and transmission curves have been plotted. The transmission curve shows that the variation of all sample materials decreases with increasing photon energy.

  3. Single-crystal CVD diamond detector for low-energy charged particles with energies ranging from 100 keV to 2 MeV

    SciTech Connect

    Yuki Sato; Hiroyuki Murakami; Takehiro Shimaoka; Masakatsu Tsubota; Junichi, H. Kaneko

    2015-07-01

    The performance of a diamond detector made of a single-crystal diamond grown by chemical vapor deposition was studied for charged particles, having energies ranging from 100 keV to 2 MeV. Energy peaks of these low-energy ions were clearly observed. However, we observed that the pulse height for individual incident ion decreases with increasing atomic number of the ions. We estimated the charge collection efficiency of the generated charge carriers by charged particle incident. The charge collection above ∼95% is achieved for helium (He{sup +}) with the energy above 1.5 MeV. On the other hand, the charge collection efficiency for heavy-ions shows wrong values compared with that of He{sup +}, ∼70% for silicon (Si{sup +}) and 35 to 40% for gold (Au{sup 3+}), at the same incident energy range, respectively. (authors)

  4. First direct high-precision energy determination for the 8.4 and 20.7 keV nuclear transitions in 169Tm

    NASA Astrophysics Data System (ADS)

    Inoyatov, A. Kh.; Kovalík, A.; Filosofov, D. V.; Ryšavý, M.; Perevoshchikov, L. L.; Gurov, Yu. B.

    2015-06-01

    Energies of 8410.1 ± 0.4, 20743.9 ± 0.3, and 63121.6 ± 1.2 eV were determined for the 8.4 keV M1 + E2, 20.7 keV M1 + E2, and 63.1 keV E1 nuclear transitions in 169Tm (generated in the EC decay of 169Yb, respectively, by means of the internal conversion electron spectroscopy. The 169Yb sources used were prepared by vacuum evaporation deposition on polycrystalline carbon and platinum foils as well as by ion implantation at 30keV into a polycrystalline aluminum foil. The relevant conversion electron spectra were measured by a high-resolution combined electrostatic electron spectrometer at 7 eV instrumental resoluition. Values of 0.0326(14) and 0.0259(17) were derived from our experimental data for the E2 admixture parameter |δ ( E2/ M1)| for the 8.4 and 20.7 keV transitions, respectively. A possible effect of nuclear structure on multipolarity of the 20.7 keV transition was also investigated.

  5. Luminescent collisions of He+ and He++ ions with H2 molecules at energies below 2 keV

    NASA Astrophysics Data System (ADS)

    Pranszke, B.; Werbowy, S.; Miotk, R.; Borkowski, K. J.; Kowalski, A.

    2013-10-01

    Spectroscopic studies of collisions between He+ and He++ ions with H2 gas target have been performed in the 200-600 nm wavelength range. Atomic lines of hydrogen Balmer series and several helium lines were identified and their excitation functions between 50 eV and 1 keV (2 keV for He++) were determined.

  6. Development of multilayer laminar-type diffraction gratings to achieve high diffraction efficiencies in the 1-8 keV energy region

    NASA Astrophysics Data System (ADS)

    Ishino, Masahiko; Heimann, Philip A.; Sasai, Hiroyuki; Hatayama, Masatoshi; Takenaka, Hisataka; Sano, Kazuo; Gullikson, Eric M.; Koike, Masato

    2006-09-01

    W/C and Co/SiO2 multilayer gratings have been fabricated by depositing a multilayer coating on the surface of laminar-type holographic master gratings. The diffraction efficiency was measured by reflectometers in the energy region of 0.6-8.0 keV at synchrotron radiation facilities as well as with an x-ray diffractometer at 8.05 keV. The Co/SiO2 and W/C multilayer gratings showed peak diffraction efficiencies of 0.47 and 0.38 at 6.0 and 8.0 keV, respectively. To our knowledge, the peak efficiency of the W/C multilayer grating is the highest measured with hard x rays. The diffraction efficiency of the Co/SiO2 multilayer gratings was higher than that of the W/C multilayer grating in the energy range of 2.5-6.0 keV. However, it decreased significantly in the energy above the K absorption edge of Co (7.71 keV). For the Co/SiO2 multilayer grating, the measured diffraction efficiencies agreed with the calculated curves assuming a rms roughness of ˜1 nm.

  7. Neutron Fluence and Energy Reconstruction with the LNE-IRSN/MIMAC Recoil Detector MicroTPC at 27 keV

    SciTech Connect

    Maire, D.; Lebreton, L.; Querre, Ph.; Bosson, G.; Guillaudin, O.; Muraz, J.F.; Riffard, Q.; Santos, D.

    2015-07-01

    The French Institute for Radiation protection and Nuclear Safety (IRSN), designated by the French Metrology Institute (LNE) for neutron metrology, is developing a time projection chamber using a Micromegas anode: microTPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize the energy distribution of neutron fluence in the energy range 8 keV - 5 MeV with a primary procedure. The time projection chambers are gaseous detectors able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulation of the detector response. The μTPC is a new reliable detector able to measure energy distribution of the neutron fluence without unfolding procedure or prior neutron calibration contrary to usual gaseous counters. The microTPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27 keV and 144 keV are shown and compared to the complete detector response simulation. This work

  8. Classical physics impossibility of magnetic fusion reactor with neutral beam injection at thermonuclear energies below 200 KeV

    NASA Astrophysics Data System (ADS)

    Maglich, Bogdan; Hester, Timothy; Vaucher, Alexander

    2016-10-01

    Lawson criterion was specifically derived for inertial fusion and DT gas of stable lifetime without ions and magnetic fields. It was revised with realistic parametrers. To account for the losses of unstable ions against neutralization with lifetime τ, n (t) = nτ [ 1 - exp (- t / - tτ τ) ] -> nτ for τ << t , where τ-1 =n0 [ ERR : md : MbegChr = 0 x 2329 , MendChr = 0 x 232 A , nParams = 1 ] , residual gas density. Second revised criterion becomes: ntL =1014cm-3 s , tL = Lawson conf. time becomes nτtL =1014 orntL =1016 / τ . In CT resonance regime below critical energy To, τ 10-5 , and Lawson requirement ntL 1021 i.e. not realistic. Luminosity (reaction rate for σ = 1) is that of two unstable particles each with lifetime τ: L =n2(t)v12 =n2t2v12 . In subcritical regime, L =10-10n2 forn =1014cm-3 , v 109 cms-1 = L =1027 . Which is negligible and implies a negative power flow reactor. But above T0 , atTD = 725 KeV , τ = 20 s was observed implying L =1039 i.e. massive fusion energy production.

  9. Effective atomic numbers and electron densities of some biologically important compounds containing H, C, N and O in the energy range 145 1330 keV

    NASA Astrophysics Data System (ADS)

    Manjunathaguru, V.; Umesh, T. K.

    2006-09-01

    A semi-empirical relation which can be used to determine the total attenuation cross sections of samples containing H, C, N and O in the energy range 145-1332 keV has been derived based on the total attenuation cross sections of several sugars, amino acids and fatty acids. The cross sections have been measured by performing transmission experiments in a narrow beam good geometry set-up by employing a high-resolution hyperpure germanium detector at seven energies of biological importance such as 145.4 keV, 279.2 keV, 514 keV, 661.6 keV, 1115.5 keV, 1173.2 keV and 1332.1 keV. The semi-empirical relation can reproduce the experimental values within 1-2%. The total attenuation cross sections of five elements carbon, aluminium, titanium, copper and zirconium measured in the same experimental set-up at the energies mentioned above have been used in a new matrix method to evaluate the effective atomic numbers and the effective electron densities of samples such as cholesterol, fatty acids, sugars and amino acids containing H, C, N and O atoms from their effective atomic cross sections. The effective atomic cross sections are the total attenuation cross sections divided by the total number of atoms of all types in a particular sample. Further, a quantity called the effective atomic weight was defined as the ratio of the molecular weight of a sample to the total number of atoms of all types in it. The variation of the effective atomic number was systematically studied with respect to the effective atomic weight and a new semi-empirical relation for Zeff has been evolved. It is felt that this relation can be very useful to determine the effective atomic number of any sample having H, C, N and O atoms in the energy range 145-1332 keV irrespective of its chemical structure.

  10. A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

    NASA Technical Reports Server (NTRS)

    Paciesas, W. S.; Baker, R.; Boclet, D.; Brown, S.; Cline, T.; Costlow, H.; Durouchoux, P.; Ehrmann, C.; Gehrels, N.; Hameury, J. M.

    1983-01-01

    The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

  11. A balloon-borne instrument for high-resolution astrophysical spectroscopy in the 20-8000 keV energy range

    NASA Astrophysics Data System (ADS)

    Paciesas, W. S.; Baker, R.; Boclet, D.; Brown, S.; Cline, T.; Costlow, H.; Durouchoux, P.; Ehrmann, C.; Gehrels, N.; Hameury, J. M.

    1983-04-01

    The Low Energy Gamma ray Spectrometer (LEGS) is designed to perform fine energy resolution measurements of astrophysical sources. The instrument is configured for a particular balloon flight with either of two sets of high purity germanium detectors. In one configuration, the instrument uses an array of three coaxial detectors (effective volume equal to or approximately 230 cubic cm) inside an NaI (T1) shield and collimator (field of view equal to or approximately 16 deg FWHM) and operates in the 80 to 8000 keV energy range. In the other configuration, three planar detectors (effective area equal to or approximately square cm) surrounded by a combination of passive Fe and active NaI for shielding and collimation (field of view equal to or approximately 5 deg x 10 deg FWHM) are optimized for the 20 to 200 keV energy range. In a typical one day balloon flight, LEGS sensitivity limit (3 sigma) for narrow line features is less than or approximately .0008 ph/cm/s square (coaxial array: 80 to 2000 keV) and less than or approximately .0003 ph/square cm/s (planar array: 50 to 150 keV).

  12. Measurement of vibrational energy transfer of OH (A2S+,v'=1?0) in low-pressure flames

    NASA Astrophysics Data System (ADS)

    Hartlieb, A. T.; Markus, D.; Kreutner, W.; Kohse-Höinghaus, K.

    1997-07-01

    Vibrational energy transfer (VET) and electronic quenching of OH (A2D+) was measured in a low-pressure H2/O2 flame for three rotational levels of OH (v'=1). Rate coefficients for collisions with H2O and N2 were determined. At 1600 K, kVET (N2) is (in 10-11 cm3s-1) 10.1DŽ, 6.1ǃ.8, and 3.8ǃ.3 for N'=0, 5, and 13, respectively. The kVET (H2O) is <1.1ǃ.8. The kQ (N2) is <2.4NJ for both vibrational levels. The kQ (H2O) in v'=1 is 59.1Lj.5, 54.7Lj.4, and 54.9Lj.6 for N'=0, 5, and 13, respectively, and, determined indirectly, 74.6ᆞ.4, 70.6ᆞ.3, and 63.4lj.3 for N'=0, 5, and 13 in v'=0. A multi-level model of OH population dynamics, which is being developed for the quantitative simulation of experimental LIF spectra, was extended to include VET. It was attempted to simulate state-to-state-specific VET coefficients for N2 collisions. From these simulations it appears that angular momentum conservation does not determine the N dependence of the vibrational relaxation step.

  13. FIRST INTEGRAL OBSERVATIONS OF V404 CYGNI DURING THE 2015 OUTBURST: SPECTRAL BEHAVIOR IN THE 20–650 KeV ENERGY RANGE

    SciTech Connect

    Roques, Jean-Pierre; Jourdain, Elisabeth; Bazzano, Angela; Fiocchi, Mariateresa; Natalucci, Lorenzo; Ubertini, Pietro

    2015-11-01

    In 2015 June, the source V404 Cygni (= GS2023+38) underwent an extraordinary outburst. We present the results obtained during the first revolution dedicated to this target by the INTEGRAL mission and focus on the spectral behavior in the hard X-ray domain, using both SPI and IBIS instruments. The source exhibits extreme variability and reaches fluxes of several tens of Crab. However, the emission between 20 and 650 keV can be understood in terms of two main components, varying on all the observable timescales, similar to what is observed in the persistent black hole system Cyg X-1. The low-energy component (up to ∼200 keV) presents a rather unusual shape, probably due to the intrinsic source variability. Nonetheless, a satisfactory description is obtained with a Comptonization model, if an unusually hot population of seed photons (kT{sub 0} ∼ 7 keV) is introduced. Above this first component, a clear excess extending up to 400–600 keV leads us to investigate a scenario where an additional (cutoff) power law could correspond to the contribution of the jet synchrotron emission, as proposed in Cyg X-1. A search for an annihilation feature did not provide any firm detection, with an upper limit of 2 × 10{sup −4} ph cm{sup −2} s{sup −1} (2σ) for a narrow line centered at 511 keV, on the averaged obtained spectrum.

  14. Measurement of high-energy (10–60 keV) x-ray spectral line widths with eV accuracy

    SciTech Connect

    Seely, J. F. Feldman, U.; Glover, J. L.; Hudson, L. T.; Ralchenko, Y.; Henins, Albert; Pereira, N.; Di Stefano, C. A.; Kuranz, C. C.; Drake, R. P.; Chen, Hui; Williams, G. J.; Park, J.

    2014-11-15

    A high resolution crystal spectrometer utilizing a crystal in transmission geometry has been developed and experimentally optimized to measure the widths of emission lines in the 10–60 keV energy range with eV accuracy. The spectrometer achieves high spectral resolution by utilizing crystal planes with small lattice spacings (down to 2d = 0.099 nm), a large crystal bending radius and Rowland circle diameter (965 mm), and an image plate detector with high spatial resolution (60 μm in the case of the Fuji TR image plate). High resolution W L-shell and K-shell laboratory test spectra in the 10–60 keV range and Ho K-shell spectra near 47 keV recorded at the LLNL Titan laser facility are presented. The Ho K-shell spectra are the highest resolution hard x-ray spectra recorded from a solid target irradiated by a high-intensity laser.

  15. High Voltage-Cylinder Sector Analyzer 300/15: A cylindrical sector analyzer for electron kinetic energies up to 15 keV

    NASA Astrophysics Data System (ADS)

    Rubio-Zuazo, J.; Escher, M.; Merkel, M.; Castro, G. R.

    2010-04-01

    We have developed an energy analyzer, High Voltage-Cylinder Sector Analyzer 300/15, for electron kinetic energies up to 15 keV. It is especially suited for hard x-ray photoelectron spectroscopy, but also for ultraviolet and soft x-ray photoelectron spectroscopy (ultraviolet photoemission spectroscopy, x-ray photoemission spectroscopy), Auger electron spectroscopy, and reflection high energy electron spectroscopy. The analyzer is based on a cylinder sector with 90° deflection, 300 mm slit-to-slit distance, and a four-element pre-retarding lens system with 50 mm sample-to-lens distance. The result is a very compact design of the analyzer that is easily integrated into a multipurpose experiment with different techniques. A low noise/low drift electronics is capable of continuous energy scans from 0 to 15 keV using nonlinear lens curves. The first analyzer is allocated at the Spanish CRG SpLine beamline at the ESRF at an end station where simultaneous surface x-ray diffraction is possible. The analyzer is operated routinely since 2006 up to 15 keV electron kinetic energy, expanding the achievable electron kinetic energy range compared to other commercial analyzers. In this work we present a detailed description of the developed electron analyzer. The analyzer capabilities, in terms of energy resolution and transmission, are shown by using an electron gun, an ultraviolet-discharge lamp, and hard x-ray synchrotron radiation as excitation sources.

  16. Variation in the calibrated response of LiF, Al2O3, and silicon dosimeters when used for in-phantom measurements of source photons with energies between 30 KeV AND 300 KeV.

    PubMed

    Poudel, Sashi; Currier, Blake; Medich, David C

    2015-04-01

    The MCNP5 radiation transport code was used to quantify changes in the absorbed dose conversion factor for LiF, Al2O3, and silicon-based electronic dosimeters calibrated in-air using standard techniques and summarily used to measure absorbed dose to water when placed in a water phantom. A mono-energetic photon source was modeled at energies between 30 keV and 300 keV for a point-source placed at the center of a water phantom, a point-source placed at the surface of the phantom, and for a 10-cm radial field geometry. Dosimetric calculations were obtained for water, LiF, Al2O3, and silicon at depths of 0.2 cm and 10 cm from the source. These results were achieved using the MCNP5 *FMESH photon energy-fluence tally, which was coupled with the appropriate DE/DF card for each dosimetric material studied to convert energy-fluence into the absorbed dose. The dosimeter's absorbed dose conversion factor was calculated as a ratio of the absorbed dose to water to that of the dosimeter measured at a specified phantom depth. The dosimeter's calibration value also was obtained. Based on these results, the absorbed dose conversion factor for a LiF dosimeter was found to deviate from its calibration value by up to 9%, an Al2O3 dosimeter by 43%, and a silicon dosimeter by 61%. These data therefore can be used to obtain LiF, Al2O3, and silicon dosimeter correction factors for mono-energetic and poly-energetic sources at measurement depths up to 10 cm under the irradiation geometries investigated herein.

  17. Interferometric phase-contrast X-ray CT imaging of VX2 rabbit cancer at 35keV X-ray energy

    SciTech Connect

    Takeda, Tohoru; Wu Jin; Tsuchiya, Yoshinori; Lwin, Thet-Thet; Itai, Yuji; Yoneyama, Akio; Hyodo, Kazuyuki

    2004-05-12

    Imaging of large objects at 17.7-keV low x-ray energy causes huge x-ray exposure to the objects even using interferometric phase-contrast x-ray CT (PCCT). Thus, we tried to obtain PCCT images at high x-ray energy of 35keV and examined the image quality using a formalin-fixed VX2 rabbit cancer specimen with 15-mm in diameter. The PCCT system consisted of an asymmetrically cut silicon (220) crystal, a monolithic x-ray interferometer, a phase-shifter, an object cell and an x-ray CCD camera. The PCCT at 35 keV clearly visualized various inner structures of VX2 rabbit cancer such as necrosis, cancer, the surrounding tumor vessels, and normal liver tissue. Besides, image-contrast was not degraded significantly. These results suggest that the PCCT at 35 KeV is sufficient to clearly depict the histopathological morphology of VX2 rabbit cancer specimen.

  18. Multilayer Fresnel zone plates for high energy radiation resolve 21 nm features at 1.2 keV.

    PubMed

    Keskinbora, Kahraman; Robisch, Anna-Lena; Mayer, Marcel; Sanli, Umut T; Grévent, Corinne; Wolter, Christian; Weigand, Markus; Szeghalmi, Adriana; Knez, Mato; Salditt, Tim; Schütz, Gisela

    2014-07-28

    X-ray microscopy is a successful technique with applications in several key fields. Fresnel zone plates (FZPs) have been the optical elements driving its success, especially in the soft X-ray range. However, focusing of hard X-rays via FZPs remains a challenge. It is demonstrated here, that two multilayer type FZPs, delivered from the same multilayer deposit, focus both hard and soft X-rays with high fidelity. The results prove that these lenses can achieve at least 21 nm half-pitch resolution at 1.2 keV demonstrated by direct imaging, and sub-30 nm FWHM (full-pitch) resolution at 7.9 keV, deduced from autocorrelation analysis. Reported FZPs had more than 10% diffraction efficiency near 1.5 keV.

  19. An innovative experimental setup for the measurement of sputtering yield induced by keV energy ions.

    PubMed

    Salou, P; Lebius, H; Benyagoub, A; Langlinay, T; Lelièvre, D; Ban-d'Etat, B

    2013-09-01

    An innovative experimental equipment allowing to study the sputtering induced by ion beam irradiation is presented. The sputtered particles are collected on a catcher which is analyzed in situ by Auger electron spectroscopy without breaking the ultra high vacuum (less than 10(-9) mbar), avoiding thus any problem linked to possible contamination. This method allows to measure the angular distribution of sputtering yield. It is now possible to study the sputtering of many elements such as carbon based materials. Preliminary results are presented in the case of highly oriented pyrolytic graphite and tungsten irradiated by an Ar(+) beam at 2.8 keV and 7 keV, respectively.

  20. The response of a fast phosphor screen scintillator (ZnO:Ga) to low energy ions (0-60 keV)

    SciTech Connect

    Jimenez-Rey, D.; Rodriguez-Barquero, L.

    2010-10-15

    ZnO:Ga is a promising, high time resolution candidate for use as a fast-ion-loss detector in TJ-II. We compare its ionoluminescence with that of the standard fast-ion-loss detector material, SrGa{sub 2}S{sub 4}:Eu (also known as TG-Green), when irradiated by H{sup +} ions with a range of energies E{<=}60 keV using a dedicated laboratory setup. It is found that ZnO:Ga is a reasonably good candidate for detecting low energy (E<60 keV) ions as it has excellent time resolution; however, its sensitivity is about 100 times lower than TG-Green, potentially limiting it to applications with high energy ion loss signals.

  1. An improved long counter for neutron fluence measurement with a flat response over a wide energy range from 1 keV to 15 MeV

    NASA Astrophysics Data System (ADS)

    Hu, Q. Y.; Zhang, J. H.; Zhang, D.; Guo, H. S.; Yang, G. Z.; Li, B. J.; Ye, F.; Si, F. N.; Liu, J.; Fu, Y. C.; Ning, J. M.; Yang, J.; Yang, H. H.; Wang, W. C.

    2014-12-01

    A new long counter has been developed with a flat energy response over a wide range from 1 keV to 15 MeV. It consists of five 3He proportional counter tubes and a number of carefully designed polyethylene moderators. The structure of this detector was determined by careful Monte Carlo simulations. The calculated results show that the efficiency of this counter is uniform from 1 keV neutron energy to 15 MeV. Calibration was performed on an Am-Be source and the accelerator-produced monoenergetic D-D and D-T neutron sources. Fluctuation of the response curve is less than 10% over this energy range.

  2. Energy and fluence calibration of the neutron spectrometer ROSPEC at the IRSN AMANDE facility between 70 keV and 4.5 MeV.

    PubMed

    Benmosbah, M; Asselineau, B

    2009-07-01

    The ROSPEC device is a multi-detector system, which has been designed by Bubble Technologies Industries (BTI at Chalk River, ON, Canada) to assess neutron spectra, and hence neutron dose quantities, at workplace fields. It is made up of six gaseous proportional counters that detect neutrons via the elastic (n,p) scattering (four hydrogenous counters) and with the (3)He(n,p)T reaction (two (3)He-filled counters). Results of the calibration of a similar rotating spectrometer (ROSPEC) have been described by Rosenstock et al.((1)). For energy and fluence calibration purposes, measurements were performed with the accelerator for metrology and neutron applications in external dosimetry (AMANDE) facility at the Laboratory of Neutron Metrology and Dosimetry (Institute of Radiation Protection and Nuclear Safety, IRSN, France). This facility provides monoenergetic neutron radiation fields from 2 keV to 20 MeV. Two kinds of experiments were carried out. First, the ROSPEC was used in its rotational mode for the ISO energies. Then, each detector was irradiated with all the available neutron energies, in a well defined position with the rotation of the device stopped. The energy values of the neutron beam were calculated using the TARGET code. A BC501-A liquid scintillation spectrometer provided the fluence values for energies beyond 1.2 MeV, a methane-filled SP2 counter from 800 keV to 1.4 MeV and an H(2)-filled SP2 counter from 144 to 800 keV. Reference data for 70 keV monoenergetic neutrons were obtained using the IRSN Long Counter. Results showed that the ROSPEC device was in agreement with the absolute neutron fluences within 10%. Moreover, the new energy calibration factors are in good agreement with those derived by BTI.

  3. Two-photon above-threshold ionization of hydrogen over the photon energy range from 15 eV to 50 keV

    SciTech Connect

    Florescu, Viorica; Budriga, Olimpia; Bachau, Henri

    2011-09-15

    We investigate the absorption of two identical photons from the ground state of hydrogen-like atoms over an energy range that extends beyond that explored up to now. Our approach is based on a hybrid formula, valid in second-order perturbation theory, in which the A{sup 2} contribution from the nonrelativistic Hamiltonian is treated exactly, while the A{center_dot}P contribution is calculated in dipole approximation. We find that, at least up to 50 keV, the nonrelativistic dipole approximation, based only on the A{center_dot}P contribution, determines the values of the total cross section. Our numerical results, covering photon energies from 90 nm (13.7 eV) to 0.0248 nm (50 keV) are in very good agreement with most previous theoretical works. Differences with recent results are discussed.

  4. Electron density of Rhizophora spp. wood using Compton scattering technique at 15.77, 17.48 and 22.16 keV XRF energies

    NASA Astrophysics Data System (ADS)

    Shakhreet, B. Z.; Bauk, S.; Shukri, A.

    2015-02-01

    Compton (incoherently) scattered photons which are directly proportional to the electron density of the scatterer, have been employed in characterizing Rhizophora spp. as breast tissue equivalent. X-ray fluorescent scattered incoherently from Rhizophora spp. sample was measured using Si-PIN detector and three XRF energy values 15.77, 17.48 and 22.16 keV. This study is aimed at providing electron density information in support of the introduction of new tissue substitute materials for mammography phantoms.

  5. Measurement of lineal-energy distributions for neutrons of 8 keV to 65 MeV by using a tissue-equivalent proportional counter.

    PubMed

    Nunomiya, T; Kim, E; Kurosaw, T; Taniguchi, S; Nakamura, T; Nakane, Y; Sakamoto, Y; Tanaka, S

    2002-01-01

    The lineal-energy spectra for monoenergetic and quasi-monoenergetic neutrons of 8 keV to 65 MeV were obtained using a tissue-equivalent proportional counter (TEPC). The frequency-mean lineal energy, the dose-average lineal energy and mean quality factor were estimated from the measured data. The neutron absorbed doses obtained with this TEPC were compared with the kerma coefticient for A-150 plastic defined by ICRP 26 and the mean quality factors were compared with the data of ICRP 74. respectively. These comparisons indicated good agreement between them.

  6. Moiré deflectometry using the Talbot-Lau interferometer as refraction diagnostic for High Energy Density plasmas at energies below 10 keV

    SciTech Connect

    Valdivia, M. P.; Stutman, D.; Finkenthal, M.

    2014-07-15

    The highly localized density gradients expected in High Energy Density (HED) plasma experiments can be characterized by x-ray phase-contrast imaging in addition to conventional attenuation radiography. Moiré deflectometry using the Talbot-Lau grating interferometer setup is an attractive HED diagnostic due to its high sensitivity to refraction induced phase shifts. We report on the adaptation of such a system for operation in the sub-10 keV range by using a combination of free standing and ultrathin Talbot gratings. This new x-ray energy explored matches well the current x-ray backlighters used for HED experiments, while also enhancing phase effects at lower electron densities. We studied the performance of the high magnification, low energy Talbot-Lau interferometer, for single image phase retrieval using Moiré fringe deflectometry. Our laboratory and simulation studies indicate that such a device is able to retrieve object electron densities from phase shift measurements. Using laboratory x-ray sources from 7 to 15 μm size we obtained accurate simultaneous measurements of refraction and attenuation for both sharp and mild electron density gradients.

  7. First INTEGRAL Observations of V404 Cygni during the 2015 Outburst: Spectral Behavior in the 20-650 keV Energy Range

    NASA Astrophysics Data System (ADS)

    Roques, Jean-Pierre; Jourdain, Elisabeth; Bazzano, Angela; Fiocchi, Mariateresa; Natalucci, Lorenzo; Ubertini, Pietro

    2015-11-01

    In 2015 June, the source V404 Cygni (= GS2023+38) underwent an extraordinary outburst. We present the results obtained during the first revolution dedicated to this target by the INTEGRAL mission and focus on the spectral behavior in the hard X-ray domain, using both SPI and IBIS instruments. The source exhibits extreme variability and reaches fluxes of several tens of Crab. However, the emission between 20 and 650 keV can be understood in terms of two main components, varying on all the observable timescales, similar to what is observed in the persistent black hole system Cyg X-1. The low-energy component (up to ˜200 keV) presents a rather unusual shape, probably due to the intrinsic source variability. Nonetheless, a satisfactory description is obtained with a Comptonization model, if an unusually hot population of seed photons (kT0 ˜ 7 keV) is introduced. Above this first component, a clear excess extending up to 400-600 keV leads us to investigate a scenario where an additional (cutoff) power law could correspond to the contribution of the jet synchrotron emission, as proposed in Cyg X-1. A search for an annihilation feature did not provide any firm detection, with an upper limit of 2 × 10-4 ph cm-2 s-1 (2σ) for a narrow line centered at 511 keV, on the averaged obtained spectrum. Based on observations with INTEGRAL, an ESA project with instruments and science data center funded by ESA member states (especially the PI countries: Denmark, France, Germany, Italy, Spain, and Switzerland), Czech Republic, and Poland with the participation of Russia and USA.

  8. Absolute calibration of Kodak Biomax-MS film response to x rays in the 1.5- to 8-keV energy range

    SciTech Connect

    Marshall, F. J.; Knauer, J. P.; Anderson, D.; Schmitt, B. L

    2006-10-15

    The absolute response of Kodak Biomax-MS film to x rays in the range from 1.5- to 8-keV has been measured using a laboratory electron-beam generated x-ray source. The measurements were taken at specific line energies by using Bragg diffraction to produce monochromatic beams of x rays. Multiple exposures were taken on Biomax MS film up to levels exceeding optical densities of 2 as measured by a microdensitometer. The absolute beam intensity for each exposure was measured with a Si(Li) detector. Additional response measurements were taken with Kodak direct exposure film (DEF) so as to compare the results of this technique to previously published calibrations. The Biomax-MS results have been fitted to a semiempirical mathematical model (Knauer et al., these proceedings). Users of the model can infer absolute fluences from observed exposure levels at either interpolated or extrapolated energies. To summarize the results: Biomax MS has comparable sensitivity to DEF film below 3 keV but has reduced sensitivity above 3 keV ({approx}50%). The lower exposure results from thinner emulsion layers, designed for use with phosphor screens. The ease with which Biomax-MS can be used in place of DEF (same format film, same developing process, and comparable sensitivity) makes it a good replacement.

  9. Development of a long-pulse (30-s), high-energy (120-keV) ion source for neutral-beam applications

    SciTech Connect

    Tsai, C.C.; Barber, G.C.; Blue, C.W.

    1983-01-01

    Multimegawatt neutral beams of hydrogen or deuterium atoms are needed for fusion machine applications such as MFTB-B, TFTR-U, DIII-U, and FED (INTOR or ETR). For these applications, a duoPIGatron ion source is being developed to produce high-brightness deuterium beams at a beam energy of approx. 120 keV for pulse lengths up to 30 s. A long-pulse plasma generator with active water cooling has been operated at an arc level of 1200 A with 30-s pulse durations. The plasma density and uniformity are sufficient for supplying a 60-A beam of hydrogen ions to a 13- by 43-cm accelerator. A 10- by 25-cm tetrode accelerator has been operated to form 120-keV hydrogen ion beams. Using the two-dimensional (2-D) ion extraction code developed at Oak Ridge National Laboratory (ORNL), a 13- by 43-cm tetrode accelerator has been designed and is being fabricated. The aperture shapes of accelerator grids are optimized for 120-keV beam energy.

  10. RBE of nearly monoenergetic neutrons at energies of 36 keV-14.6 MeV for induction of dicentrics in human lymphocytes.

    PubMed

    Schmid, E; Schlegel, D; Guldbakke, S; Kapsch, R-P; Regulla, D

    2003-07-01

    We examined the induction of dicentric chromosomes in human lymphocytes irradiated in vitro with nearly monoenergetic neutrons at energies in the range of 36 keV-15.0 MeV. For the assessment of the relative biological effectiveness (RBE) both 220 kV x-rays and (60)Co gamma-rays were used as reference radiations. To avoid potential confounding factors that would influence the outcome of the experiments, only blood from one individual was used. The neutron RBE culture conditions ensured that the chromosome analysis could be performed exclusively in metaphases of the first cell cycle in vitro. For the reference radiation of 220 kV x-rays, the values of RBE(M) were found to increase from 16.6 (E(n)=36 keV) to the maximum value of 23.4 (E(n)=385 keV). For (60)Co gamma-rays utilized as the reference radiation, the corresponding RBE(M) values were found to be higher by a factor of 4. These results agree well with the previously published large data sets of three laboratories on dose-response relationships for dicentrics or dicentrics plus centric rings. They show a similar dependence of RBE on neutron energy.

  11. Total electron scattering cross sections of molecules containing H, C, N, O and F in the energy range 0.2-6.0 keV

    NASA Astrophysics Data System (ADS)

    Gurung, Meera Devi; Ariyasinghe, W. M.

    2017-03-01

    Based on the effective atomic total electron scattering cross sections (EATCS) of atoms in a molecular environment, a simple model is proposed to predict the total electron scattering cross sections (TCS) of H, C, N, O, and F containing molecules. The EATCS for these five atoms are reported for 0.2-6.0 keV energies. The predicted TCS by this model are compared with experimental TCS in the literature. The experimental TCS of CHF3, C2F4, C2F2H2, C4F6, and c-C4F8 have been obtained for 0.2-4.5 keV electrons by measuring the attenuation of the electron beam through a gas cell.

  12. Interaction model for electron scattering from ethylene in the energy range 1-10 000 eV

    NASA Astrophysics Data System (ADS)

    Fuss, M. C.; Sanz, A. G.; Muñoz, A.; Do, T. P. D.; Nixon, K.; Brunger, M. J.; Hubin-Franskin, M.-J.; Oller, J. C.; Blanco, F.; García, G.

    2013-02-01

    We present new experimental electron energy loss distribution functions for ethylene (C2H4) measured with two different apparatus (Liège and Madrid) in different incident electron energy ranges. Theoretical cross sections for electron scattering from C2H4 were calculated using the screening-corrected additivity rule (IAM-SCAR) method. Through a critical comparison of our new data and existing results from other groups, we obtain a self-consistent set of recommended interaction cross section values and energy loss spectra. Finally, electron tracks in C2H4 are simulated with our Low Energy Particle Track Simulation (LEPTS) in order to demonstrate the efficacy of our recommended data.

  13. A low background-rate detector for ions in the 5 to 50 keV energy range to be used for radioisotope dating with a small cyclotron

    SciTech Connect

    Friedman, P.G.

    1986-11-25

    Accelerator mass spectrometry in tandem Van de Graaff accelerators has proven successful for radioisotope dating small samples. We are developing a 20 cm diameter 30 to 40 keV cyclotron dedicated to high-sensitivity radioisotope dating, initially for /sup 14/C. At this energy, range and dE/dx methods of particle identification are impossible. Thus arises the difficult problem of reliably detecting 30 to 40 keV /sup 14/C at 10/sup -2/ counts/sec in the high background environment of the cyclotron, where lower energy ions, electrons, and photons bombard the detector at much higher rates. We have developed and tested an inexpensive, generally useful ion detector that allows dark-count rates below 10/sup -4/ counts/sec and excellent background suppression. With the cyclotron tuned near the /sup 13/CH background peak, to the frequency for /sup 14/C, the detector suppresses the background to 6 x 10/sup -4/ counts/sec. For each /sup 14/C ion the detectors grazing-incidence Al/sub 2/O/sub 3/ conversion dynode emits about 20 secondary electrons, which are independently multiplied in separate pores of a microchannel plate. The output signal is proportional to the number of secondary electrons, allowing pulse-height discrimination of background. We have successfully tested the detector with positive /sup 12/C, /sup 23/Na, /sup 39/K, /sup 41/K, /sup 85/Rb, /sup 87/Rb, and /sup 133/Cs at 5 to 40 keV, and with 36 keV negative /sup 12/C and /sup 13/CH. It should detect ions and neutrals of all species, at energies above 5 keV, with good efficiency and excellent background discrimination. Counting efficiency and background discrimination improve with higher ion energy. The detector can be operated at least up to 2 x 10/sup -7/ Torr and be repeatedly exposed to air. The maximum rate is 10/sup 6.4/ ions/sec in pulse counting mode and 10/sup 9.7/ ions/sec in current integrating mode.

  14. High-energy (>70 keV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Chen, Hui; Hermann, M. R.; Kalantar, D. H.; Martinez, D. A.; Di Nicola, P.; Tommasini, R.; Landen, O. L.; Alessi, D.; Bowers, M.; Browning, D.; Brunton, G.; Budge, T.; Crane, J.; Di Nicola, J.-M.; Döppner, T.; Dixit, S.; Erbert, G.; Fishler, B.; Halpin, J.; Hamamoto, M.; Heebner, J.; Hernandez, V. J.; Hohenberger, M.; Homoelle, D.; Honig, J.; Hsing, W.; Izumi, N.; Khan, S.; LaFortune, K.; Lawson, J.; Nagel, S. R.; Negres, R. A.; Novikova, L.; Orth, C.; Pelz, L.; Prantil, M.; Rushford, M.; Shaw, M.; Sherlock, M.; Sigurdsson, R.; Wegner, P.; Widmayer, C.; Williams, G. J.; Williams, W.; Whitman, P.; Yang, S.

    2017-03-01

    The Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20-30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4-9 × 10-4 for x-rays with energies greater than 70 keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.

  15. High-energy (> 70 KeV) x-ray conversion efficiency measurement on the ARC laser at the National Ignition Facility

    DOE PAGES

    Chen, Hui; Hermann, M. R.; Kalantar, D. H.; ...

    2017-03-16

    Here, the Advanced Radiographic Capability (ARC) laser system at the National Ignition Facility (NIF) is designed to ultimately provide eight beamlets with a pulse duration adjustable from 1 to 30 ps, and energies up to 1.5 kJ per beamlet. Currently, four beamlets have been commissioned. In the first set of 6 commissioning target experiments, the individual beamlets were fired onto gold foil targets with energy up to 1 kJ per beamlet at 20–30 ps pulse length. The x-ray energy distribution and pulse duration were measured, yielding energy conversion efficiencies of 4–9 × 10–4 for x-rays with energies greater than 70more » keV. With greater than 3 J of such x-rays, ARC provides a high-precision x-ray backlighting capability for upcoming inertial confinement fusion and high-energy-density physics experiments on NIF.« less

  16. Bremsstrahlung in Mo and Pt targets produced by {sup 90}Sr beta particles in the photon energy region of 1-100 keV

    SciTech Connect

    Singh, Amrit; Dhaliwal, A. S.

    2015-08-28

    Bremsstrahlung spectra in thick targets of Mo and Pt, produced by beta emitter {sup 90}Sr (end point energy = 546 keV) have been studied in the photon energy range of 1-100 keV. The experimentally measured bremsstrahlung spectra measured with Si(Li) detector were compared with the theoretical spectral distributions calculated from Elwert corrected (non relativistic) Bethe-Heitler [EBH] theory, modified Elwert factor (relativistic) Bethe-Heitler (F{sub mod}BH) theory for ordinary bremsstrahlung (OB) and the modified Elwert factor (relativistic) Bethe-Heitler (F{sub mod}BH+PB) theory, which includes the polarization bremsstrahlung (PB) into total bremsstrahlung (BS). The present results indicate the correctness of F{sub mod}BH+PB theory in the low energy region, where the contributions of PB into BS are dominant, which is described in terms of stripped atom (SA) approximation. But at the middle and higher energy region of the bremsstrahlung spectrum, where the contribution of PB is negligible, the F{sub mod}BH theory is more close to the experimental results. Hence, it is clear that the production of PB in the low energy region, due to the dynamic response of the target atom suppresses the production of bremsstrahlung at higher energy ends.

  17. Study of effective atomic number and electron density for tissues from human organs in the energy range of 1 keV-100 GeV.

    PubMed

    Manjunatha, H C; Rudraswamy, B

    2013-02-01

    Effective atomic numbers' (Z(eff)) effective electron density (N(el)) for human organs and tissues have been computed in the energy region of 1 keV to 100 GeV using WinXCOM. The computed data of Z(eff) and N(el) are tabulated. The computed values are compared with previous results. The computed data of Z(eff)and N(el)for almost all tissues (34 tissues of different human organs) in the given energy range are not available in literature and find application in radiotherapy and dosimetry.

  18. Experimental study of interactions of highly charged ions with atoms at keV energies. Progress report, February 16, 1993--April 15, 1994

    SciTech Connect

    Kostroun, V.O.

    1994-04-27

    Experimental study of low energy, highly charged ions with other atomic species requires an advanced ion source such as an electron beam ion source, EBIS or an electron cyclotron ion source, ECRIS. Five years ago we finished the design and construction of the Cornell superconducting solenoid, cryogenic EBIS (CEBIS). Since then, this source has been in continuous operation in a program whose main purpose is the experimental study of interactions of highly charged ions with atoms at keV energies. This progress report for the period February 16, 1993 to April 15, 1994 describes the work accomplished during this time in the form of short abstracts.

  19. Reduction in the intensity of solar X-ray emission in the 2- to 15-keV photon energy range and heating of the solar corona

    SciTech Connect

    Mirzoeva, I. K.

    2013-04-15

    The time profiles of the energy spectra of low-intensity flares and the structure of the thermal background of the soft X-ray component of solar corona emission over the period of January-February, 2003, are investigated using the data of the RHESSI project. A reduction in the intensity of X-ray emission of the solar flares and the corona thermal background in the 2- to 15-keV photon energy range is revealed. The RHESSI data are compared with the data from the Interball-Geotail project. A new mechanism of solar corona heating is proposed on the basis of the results obtained.

  20. Neutron Resonance Parameters of 238U and the Calculated Cross Sections from the Reich-Moore Analysis of Experimental Data in the Neutron Energy Range from 0 keV to 20 keV

    SciTech Connect

    Derrien, H

    2005-12-05

    The neutron resonance parameters of {sup 238}U were obtained from a SAMMY analysis of high-resolution neutron transmission measurements and high-resolution capture cross section measurements performed at the Oak Ridge Electron Linear Accelerator (ORELA) in the years 1970-1990, and from more recent transmission and capture cross section measurements performed at the Geel Linear Accelerator (GELINA). Compared with previous evaluations, the energy range for this resonance analysis was extended from 10 to 20 keV, taking advantage of the high resolution of the most recent ORELA transmission measurements. The experimental database and the method of analysis are described in this report. The neutron transmissions and the capture cross sections calculated with the resonance parameters are compared with the experimental data. A description is given of the statistical properties of the resonance parameters and of the recommended values of the average parameters. The new evaluation results in a slight decrease of the effective capture resonance integral and improves the prediction of integral thermal benchmarks by 70 pcm to 200 pcm.

  1. Energy-dependent dynamics of keV to MeV electrons in the inner zone, outer zone, and slot regions

    SciTech Connect

    Reeves, Geoffrey D.; Friedel, Reiner H. W.; Larsen, Brian A.; Skoug, Ruth M.; Funsten, Herbert O.; Claudepierre, Seth G.; Fennell, Joseph F.; Turner, Drew L.; Denton, Mick H.; Spence, Harlan E.; Blake, J. Bernard; Baker, Daniel N.

    2016-01-28

    Here, we present observations of the radiation belts from the Helium Oxygen Proton Electron and Magnetic Electron Ion Spectrometer particle detectors on the Van Allen Probes satellites that illustrate the energy dependence and L shell dependence of radiation belt enhancements and decays. We survey events in 2013 and analyze an event on 1 March in more detail. The observations show the following: (a) at all L shells, lower energy electrons are enhanced more often than higher energies; (b) events that fill the slot region are more common at lower energies; (c) enhancements of electrons in the inner zone are more common at lower energies; and (d) even when events do not fully fill the slot region, enhancements at lower energies tend to extend to lower L shells than higher energies. During enhancement events the outer zone extends to lower L shells at lower energies while being confined to higher L shells at higher energies. The inner zone shows the opposite with an outer boundary at higher L shells for lower energies. Both boundaries are nearly straight in log(energy) versus L shell space. At energies below a few 100 keV, radiation belt electron penetration through the slot region into the inner zone is commonplace, but the number and frequency of “slot filling” events decreases with increasing energy. The inner zone is enhanced only at energies that penetrate through the slot. Energy- and L shell-dependent losses (that are consistent with whistler hiss interactions) return the belts to more quiescent conditions.

  2. Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeV

    NASA Astrophysics Data System (ADS)

    Maigne, L.; Perrot, Y.; Schaart, D. R.; Donnarieix, D.; Breton, V.

    2011-02-01

    The GATE Monte Carlo simulation platform based on the GEANT4 toolkit has come into widespread use for simulating positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging devices. Here, we explore its use for calculating electron dose distributions in water. Mono-energetic electron dose point kernels and pencil beam kernels in water are calculated for different energies between 15 keV and 20 MeV by means of GATE 6.0, which makes use of the GEANT4 version 9.2 Standard Electromagnetic Physics Package. The results are compared to the well-validated codes EGSnrc and MCNP4C. It is shown that recent improvements made to the GEANT4/GATE software result in significantly better agreement with the other codes. We furthermore illustrate several issues of general interest to GATE and GEANT4 users who wish to perform accurate simulations involving electrons. Provided that the electron step size is sufficiently restricted, GATE 6.0 and EGSnrc dose point kernels are shown to agree to within less than 3% of the maximum dose between 50 keV and 4 MeV, while pencil beam kernels are found to agree to within less than 4% of the maximum dose between 15 keV and 20 MeV.

  3. Comparison of GATE/GEANT4 with EGSnrc and MCNP for electron dose calculations at energies between 15 keV and 20 MeV.

    PubMed

    Maigne, L; Perrot, Y; Schaart, D R; Donnarieix, D; Breton, V

    2011-02-07

    The GATE Monte Carlo simulation platform based on the GEANT4 toolkit has come into widespread use for simulating positron emission tomography (PET) and single photon emission computed tomography (SPECT) imaging devices. Here, we explore its use for calculating electron dose distributions in water. Mono-energetic electron dose point kernels and pencil beam kernels in water are calculated for different energies between 15 keV and 20 MeV by means of GATE 6.0, which makes use of the GEANT4 version 9.2 Standard Electromagnetic Physics Package. The results are compared to the well-validated codes EGSnrc and MCNP4C. It is shown that recent improvements made to the GEANT4/GATE software result in significantly better agreement with the other codes. We furthermore illustrate several issues of general interest to GATE and GEANT4 users who wish to perform accurate simulations involving electrons. Provided that the electron step size is sufficiently restricted, GATE 6.0 and EGSnrc dose point kernels are shown to agree to within less than 3% of the maximum dose between 50 keV and 4 MeV, while pencil beam kernels are found to agree to within less than 4% of the maximum dose between 15 keV and 20 MeV.

  4. Monte Carlo study of correction factors for Spencer-Attix cavity theory at photon energies at or above 100 keV.

    PubMed

    Borg, J; Kawrakow, I; Rogers, D W; Seuntjens, J P

    2000-08-01

    To develop a primary standard for 192Ir sources, the basic science on which this standard is based, i.e., Spencer-Attix cavity theory, must be established. In the present study Monte Carlo techniques are used to investigate the accuracy of this cavity theory for photons in the energy range from 20 to 1300 keV, since it is usually not applied at energies below that of 137Cs. Ma and Nahum [Phys. Med. Biol. 36, 413-428 (1991)] found that in low-energy photon beams the contribution from electrons caused by photons interacting in the cavity is substantial. For the average energy of the 192Ir spectrum they found a departure from Bragg-Gray conditions of up to 3% caused by photon interactions in the cavity. When Monte Carlo is used to calculate the response of a graphite ion chamber to an encapsulated 192Ir source it is found that it differs by less than 0.3% from the value predicted by Spencer-Attix cavity theory. Based on these Monte Carlo calculations, for cavities in graphite it is concluded that the Spencer-Attix cavity theory with delta = 10 keV is applicable within 0.5% for photon energies at 300 keV or above despite the breakdown of the assumption that there is no interaction of photons within the cavity. This means that it is possible to use a graphite ion chamber and Spencer-Attix cavity theory to calibrate an 192Ir source. It is also found that the use of delta related to the mean chord length instead of delta = 10 keV improves the agreement with Spencer-Attix cavity theory at 60Co from 0.2% to within 0.1% of unity. This is at the level of accuracy of which the Monte Carlo code EGSnrc calculates ion chamber responses. In addition, it is shown that the effects of other materials, e.g., insulators and holders, have a substantial effect on the ion chamber response and should be included in the correction factors for a primary standard of air kerma.

  5. The high-energy multi-group HEST1.0 library based on ENDF/B-VII.0: development, verification and preliminary application

    NASA Astrophysics Data System (ADS)

    Wu, Jun; Chen, Yi-Xue; Wang, Wei-Jin; Yin, Wen; Liang, Tian-Jiao; Jia, Xue-Jun

    2012-03-01

    ENDF/B-VII.0, which was released by the USA Cross Section Evaluation Working Group (CSEWG) in December 2006, was demonstrated to perform much better than previous ENDF evaluations over a broad range of benchmark experiments. A high-energy (up to 150 MeV) multi-group library set named HEST1.0 with 253-neutron and 48-photon groups has been developed based on ENDF/B-VII.0 using the NJOY code. This paper provides a summary of the procedure to produce the library set and a detailed description of the verification of the multi-group library set by several shielding benchmark devices, in particular for high-energy neutron data. In addition, the first application of HEST1.0 to the shielding design of the China Spallation Neutron Source (CSNS) is demonstrated.

  6. Energy loss of keV fluorine ions scattered off a missing-row reconstructed Au(110) surface under grazing incidence

    SciTech Connect

    Chen, L.; Shen, J.; Esaulov, V. A.; Valdes, J. E.; Vargas, P.

    2011-03-15

    A joint experimental and theoretical study of energy loss is presented for 1-to-4-keV fluorine negative ions in grazing scattering on a missing-row reconstructed Au(110) surface. Measurements of energy losses for various azimuthal orientations of the crystal have been performed by means of a time-of-flight method with a pulsed beam. The dependence of the fraction of surviving negative ions on azimuthal angles, was determined. Our energy-loss data are discussed in light of trajectory and stopping-power calculations, where the explicit inclusion of the nonuniform electron density at the surface provides good agreement with the experimental data. The simulation allows us to delineate various trajectory classes that correspond to different contributions in the energy-loss spectra for various azimuthal orientations of the surface.

  7. Surface channelling and energy losses of 4 keV hydrogen and fluorine ions in grazing scattering on Au(111) and missing row reconstructed Au(110) surfaces.

    PubMed

    Chen, L; Valdés, J E; Vargas, P; Esaulov, V A

    2010-09-01

    We present the results of an experimental and theoretical study of surface channelling and energy loss of 4 keV hydrogen and fluorine ions in grazing scattering on a missing row reconstructed Au(110) surface and a Au(111) surface. We performed measurements of energy losses for grazing angle scattering in surface channelling conditions for various azimuthal orientations of the crystal. Experimental results are discussed in the light of trajectory calculations of hydrogen and fluorine ions scattered under grazing incidence conditions on the surface. A nonlinear model is used in order to calculate the ion energy loss in these crystalline systems. Ab initio electronic crystal structure calculations and semi-classical simulations are performed and allow us to delineate various trajectory classes that correspond to different contributions in the energy loss spectra for various azimuthal orientations of the surface.

  8. Image information transfer properties of x-ray intensifying screens in the energy range from 17 to 320 keV.

    PubMed

    Ginzburg, A; Dick, C E

    1993-01-01

    The image information transfer properties of a number of x-ray fluorescent screens have been measured for x-ray energies from 17 to 320 keV. The detective quantum efficiency of the screens at each x-ray energy has been determined by separate measurements of the x-ray absorption efficiency and the statistical factor associated with the emission of optical photons upon absorption of an incident x-ray. Data have been recorded for both rare-earth phosphor screens and calcium tungstate screens. The value of the statistical factor for optical photon emission tends toward a constant value as the incident energy increases. Comparisons of the image information transfer properties are presented for several screens, which have been measured over a ten year interval. The utility of the screens for high-energy radiography is discussed.

  9. Surface modifications of hydrogen storage alloy by heavy ion beams with keV to MeV irradiation energies

    NASA Astrophysics Data System (ADS)

    Abe, Hiroshi; Tokuhira, Shinnosuke; Uchida, Hirohisa; Ohshima, Takeshi

    2015-12-01

    This study deals with the effect of surface modifications induced from keV to MeV heavy ion beams on the initial reaction rate of a hydrogen storage alloy (AB5) in electrochemical process. The rare earth based alloys like this sample alloy are widely used as a negative electrode of Ni-MH (Nickel-Metal Hydride) battery. We aimed to improve the initial reaction rate of hydrogen absorption by effective induction of defects such as vacancies, dislocations, micro-cracks or by addition of atoms into the surface region of the metal alloys. Since defective layer near the surface can easily be oxidized, the conductive oxide layer is formed on the sample surface by O+ beams irradiation, and the conductive oxide layer might cause the improvement of initial reaction rate of hydriding. This paper demonstrates an effective surface treatment of heavy ion irradiation, which induces catalytic activities of rare earth oxides in the alloy surface.

  10. Evaluation of Neutron Capture Cross Sections and Covariances on 99Tc and 129I in the keV Energy Region

    NASA Astrophysics Data System (ADS)

    Iwamoto, Nobuyuki

    2016-03-01

    Neutron capture cross sections and covariances on radioactive 99Tc and 129I have been required for developing environmental load-reducing technology. Their evaluation was performed by using nuclear reaction calculation code CCONE and Baysian code KALMAN with data assumed on the basis of measured data. The obtained total and capture cross sections are in good agreement with the measured data. The resulting uncertainties of capture cross section were 12-18% and 20-29% for 99Tc and 129I, respectively, in the keV energy region.

  11. A Review of X-ray Diagnostic Calibrations in the 2 to 100 keV Region Using the High Energy X-ray Calibration Facility (HEX)

    SciTech Connect

    Ali, Zaheer; Pond, T; Buckles, R A; Maddox, B R; Chen, C D; DeWald, E L; Izumi, N; Stewart, R

    2010-05-19

    The precise and accurate measurement of X-rays in the 2 keV to 100 keV region is crucial to the understanding of HED plasmas and warm dense matter in general. With the emergence of inertially confined plasma facilities as the premier platforms for ICF, laboratory astrophysics, and national security related plasma experiments, the need to calibrate diagnostics in the high energy X-ray regime has grown. At National Security Technologies High Energy X-ray Calibration Facility (HEX) in Livermore, California, X-ray imagers, filter-fluorescer spectrometers, crystal spectrometers, image plates, and nuclear diagnostics are calibrated. The HEX can provide measurements of atomic line radiation, X-ray flux (accuracy within 10%), and X-ray energy (accuracy within 1%). The HEX source is comprised of a commercial 160 kV X-ray tube, a fluorescer wheel, a filter wheel, and a lead encasement. The X-ray tube produces a Tungsten bremsstrahlung spectrum which causes a foil to fluoresce line radiation. To minimize bremsstrahlung in the radiation for calibration we also provide various foils as filters. For experimental purposes, a vacuum box capable of 10{sup -7} Torr, as well as HPGe and CdTe radiation detectors, are provided on an optical table. Most geometries and arrangements can be changed to meet experimental needs.

  12. Studies on effective atomic numbers and electron densities in amino acids and sugars in the energy range 30 1333 keV

    NASA Astrophysics Data System (ADS)

    Gowda, Shivalinge; Krishnaveni, S.; Gowda, Ramakrishna

    2005-10-01

    The effective atomic numbers and electron densities of the amino acids glycine, alanine, serine, valine, threonine, leucine, isoleucine, aspartic acid, lysine, glutamic acid, histidine, phenylalanine, arginine, tyrosine, tryptophane and the sugars arabinose, ribose, glucose, galactose, mannose, fructose, rhamnose, maltose, melibiose, melezitose and raffinose at the energies 30.8, 35.0, 81.0, 145, 276.4, 302.9, 356, 383.9, 661.6, 1173 and 1332.5 keV were calculated by using the measured total attenuation cross-sections. The interpolations of total attenuation cross-sections for photons of energy E in elements of atomic number Z was performed using the logarithmic regression analysis of the XCOM data in the photon energy region 30-1500 keV. The best-fit coefficients obtained by a piece wise interpolation method were used to find the effective atomic number and electron density of the compounds. These values are found to be in good agreement with the theoretical values calculated based on XCOM data.

  13. Measurement of the mass energy-absorption coefficient of air for x-rays in the range from 3 to 60 keV.

    PubMed

    Buhr, H; Büermann, L; Gerlach, M; Krumrey, M; Rabus, H

    2012-12-21

    For the first time the absolute photon mass energy-absorption coefficient of air in the energy range of 10 to 60 keV has been measured with relative standard uncertainties below 1%, considerably smaller than those of up to 2% assumed for calculated data. For monochromatized synchrotron radiation from the electron storage ring BESSY II both the radiant power and the fraction of power deposited in dry air were measured using a cryogenic electrical substitution radiometer and a free air ionization chamber, respectively. The measured absorption coefficients were compared with state-of-the art calculations and showed an average deviation of 2% from calculations by Seltzer. However, they agree within 1% with data calculated earlier by Hubbell. In the course of this work, an improvement of the data analysis of a previous experimental determination of the mass energy-absorption coefficient of air in the range of 3 to 10 keV was found to be possible and corrected values of this preceding study are given.

  14. Measurement of L X-ray fluorescence cross-sections for 74W at excitation energies 12, 14, 15 and 16.5 keV with synchrotron radiation

    NASA Astrophysics Data System (ADS)

    Kumar, R.; Rani, A.; Singh, R. M.; Tiwari, M. K.; Singh, A. K.

    2017-02-01

    Ll, Lα, Lβ and Lγ1 X-ray fluorescence cross-sections for 74W have been measured at excitation energies of 12, 14, 15 and 16.5 keV using synchrotron radiations. A Peltier cooled Vortex solid state detector (SII Nano Technology, USA) with an energy resolution of 138 eV at 5.96 keV X-rays was employed for analysis. The experimental results were compared with the theoretical estimates of Krause (1979), Campbell (2003) and Puri et al. (1993) and also compared with existing experimental results (Barrea and Bonzi, 2001b) of L XRF cross sections at the excitation energy of 12 and 14 keV. Present results were found to be closer to the Puri's data in comparison to existing experimental results. For the first time, to our knowledge, L XRF cross section for 74W at energies 15 and 16.5 keV are also being reported here.

  15. Measurement of the x-ray mass attenuation coefficients of gold in the 38-50-keV energy range

    SciTech Connect

    Islam, M T; Rae, N A; Glover, J L; Barnea, Z; de Jonge, M D; Tran, C Q; Wang, J; Chantler, C T

    2010-11-12

    We used synchrotron x rays to measure the x-ray mass attenuation coefficients of gold at nine energies from 38 to 50 keV with accuracies of 0.1%. Our results are much more accurate than previous measurements in this energy range. A comparison of our measurements with calculated mass attenuation coefficients shows that our measurements fall almost exactly midway between the XCOM and FFAST calculated theoretical values, which differ from one another in this energy region by about 4%, even though the range includes no absorption edge. The consistency and accuracy of these measurements open the way to investigations of the x-ray attenuation in the region of the L absorption edge of gold.

  16. Investigation of chemical effect on the absorption parameters for some selected indium complex at 59.54 keV photon energy

    NASA Astrophysics Data System (ADS)

    Akman, F.; Akman, F.; Kaçal, M. R.; Turhan, M. F.; Akdemir, F.; Araz, A.; Durak, R.

    2016-04-01

    In this work, the mass attenuation coefficients, molecular, atomic and electronic cross sections, effective atomic numbers and electron densities of some selected indium complexes such as C5H10InNO9, C3H6InNO9 and C9H10InNO9, were determined with experimentally and theoretically using transmission geometry at 59.54 keV photon energy which emitted from 241Am annular source. The results were compared with the theoretical calculations which obtained from the WinXCOM program. Also, the results were interpreted based on some chemical parameters such as energy gap, ionization energy, electron affinity, hardness, chemical potential, electronegativity and global electrophilicity values of malonate, 2, 2 dimethylmalonate and phenylmalonate which were calculated using the density functional theory (DFT/B3LYP).

  17. Study of surface activation of PET by low energy (keV) Ni + and N + ion implantation

    NASA Astrophysics Data System (ADS)

    Nathawat, Rashi; Kumar, Anil; Kulshrestha, V.; Vijay, Y. K.; Kobayashi, T.; Kanjilal, D.

    2008-11-01

    Polyethyleneterephthalate (PET) has been modified by 100 keV Ni + and N + ions using metal ion from volatile compound (MIVOC) ion source to fluence ranging from 1 × 10 14 to 1 × 10 16 ions/cm 2. The increasing application of polymeric material in technological and scientific field has motivated the use of surface treatment to modify the physical and chemical properties of polymer surfaces. When a material is exposed to ionization radiation, it suffers damage leading to surface activation depending on the type. The surface morphology was observed by atomic force microscopy (AFM). That show the roughness increases with fluence in both the cases. The Ni particles as precipitation in PET were observed by cross-section transmission electron microscopy (XTEM). The optical band gap ( Eg) deduced from absorption spectra; was calculated by Tau'c relation. Raman spectroscopy shows quantitatively the chemical nature at the damage caused by the Ni + and N + bombardment. The ration of ID/ IG shows graphite-like structure is formed on the surface. A layer of hydrogenated amorphous carbon is formed on the surface, which has confirmed by XPS results also.

  18. Absolute measurements of short-pulse, long-pulse, and capsule-implosion backlighter sources at x-ray energies greater than 10 keV

    NASA Astrophysics Data System (ADS)

    Maddox, Brian

    2010-11-01

    Laser-generated x-ray backlighters with x-ray energies > 10 keV are becoming essential diagnostic tools for many high energy density experiments. Examples include studies of high areal density cores for ignition designs, mid- to high-Z capsule implosion experiments, absolute equation of state experiments, dynamic diffraction under extreme pressures, and the study of material strength. Significant progress has been made recently using short pulse lasers, coupled to metal foil targets [1], and imploding capsules for producing high energy backlighters. Measuring the absolute x-ray flux and spectra from these sources is required for quantitative analysis of experimental data and for the design and planning of future experiments. We have performed an extensive series of experiments to measure the absolute x-ray flux and spectra on the Titan, Omega, Omega-EP, and NIF laser systems, employing single-photon-counting detectors, crystal spectrometers, and multichannel differential filtering (Ross-pair) and filter stack bremsstrahlung spectrometers. Calibrations were performed on these instruments [2] enabling absolute measurements of backlighter spectra to be made from 10 keV to 1 MeV. Various backlighter techniques that generate either quasi-monochromatic sources or broadband continuum sources will be presented and compared. For Molybdenum Kα backlighters at x-ray energy of ˜17 keV we measure conversion efficiencies of 1.3x10-4 using 1 μm wavelength short-pulse lasers at an intensity of ˜1x10^17 W/cm^2. This is a factor of ˜2 high than using 0.3 μm wavelength long-pulse lasers at an intensity of ˜1x10^16 W/cm^2. Other types of backlighter targets include capsule implosion backlighters that can generate a very bright ``white-light'' continuum x-ray source and high-Z gas filled capsules that generate a quasi-line-source of x rays. We will present and compare the absolute laser energy to x-ray conversion efficiencies for these different backlighter techniques and give

  19. Energy dependent dynamics of keV to MeV electrons in the inner zone, outer zone, and slot regions

    NASA Astrophysics Data System (ADS)

    Reeves, G. D.; Friedel, R. H.; Larsen, B.; Skoug, R. M.; Funsten, H. O.; Claudepierre, S. G.; Fennell, J. F.; Turner, D. L.; Denton, M.; Spence, H. E.; Blake, J. B.; Baker, D. N.

    2015-12-01

    We present observations that illustrate the energy-dependence and L-shell dependence of radiation belt dynamics. We survey events in 2013 and analyze individual events in more detail. The survey data show: (a) Lower-energy electrons are enhanced more often than higher energies. (b) Events that fill the slot region are more common at lower energies. (c) Enhancements of electrons in the inner zone are more common at lower energies. And (d) even when events do not fully fill the slot region, enhancements at lower-energies tend to extend to lower L-shells than higher energies. The outer zone, inner zone, and slot region all occupy regions of space that are strongly energy dependent. During enhancement events the outer zone extends to lower L-shells at lower energies and higher L-shells at higher energies. The inner zone shows the opposite with an outer boundary at higher L-shells for lower energies. Both boundaries are nearly straight in log(energy) vs. L-shell space. At energies below a few hundred keV radiation belt electron penetration through the slot region into the inner zone is commonplace but the number and frequency of "slot filling" events decreases with increasing energy. The inner zone is enhanced only at energies that penetrate through the slot. Analysis shows that at least three processes may determine which electrons penetrate into the slot and inner zone: (1) enhanced convective electric fields at low L-shells, (2) impulsive, substorm-associated injections at low L-shells, and (3) slower radial diffusion and interaction with plasmaspheric hiss. These new observations challenge some of our long-held pictures of what the radiation belts look like and how they behave.

  20. Energy-dependent dynamics of keV to MeV electrons in the inner zone, outer zone, and slot regions

    DOE PAGES

    Reeves, Geoffrey D.; Friedel, Reiner H. W.; Larsen, Brian A.; ...

    2016-01-28

    Here, we present observations of the radiation belts from the Helium Oxygen Proton Electron and Magnetic Electron Ion Spectrometer particle detectors on the Van Allen Probes satellites that illustrate the energy dependence and L shell dependence of radiation belt enhancements and decays. We survey events in 2013 and analyze an event on 1 March in more detail. The observations show the following: (a) at all L shells, lower energy electrons are enhanced more often than higher energies; (b) events that fill the slot region are more common at lower energies; (c) enhancements of electrons in the inner zone are moremore » common at lower energies; and (d) even when events do not fully fill the slot region, enhancements at lower energies tend to extend to lower L shells than higher energies. During enhancement events the outer zone extends to lower L shells at lower energies while being confined to higher L shells at higher energies. The inner zone shows the opposite with an outer boundary at higher L shells for lower energies. Both boundaries are nearly straight in log(energy) versus L shell space. At energies below a few 100 keV, radiation belt electron penetration through the slot region into the inner zone is commonplace, but the number and frequency of “slot filling” events decreases with increasing energy. The inner zone is enhanced only at energies that penetrate through the slot. Energy- and L shell-dependent losses (that are consistent with whistler hiss interactions) return the belts to more quiescent conditions.« less

  1. Dose calculation for photon-emitting brachytherapy sources with average energy higher than 50 keV: Report of the AAPM and ESTRO

    SciTech Connect

    Perez-Calatayud, Jose; Ballester, Facundo; Das, Rupak K.; DeWerd, Larry A.; Ibbott, Geoffrey S.; Meigooni, Ali S.; Ouhib, Zoubir; Rivard, Mark J.; Sloboda, Ron S.; Williamson, Jeffrey F.

    2012-05-15

    Purpose: Recommendations of the American Association of Physicists in Medicine (AAPM) and the European Society for Radiotherapy and Oncology (ESTRO) on dose calculations for high-energy (average energy higher than 50 keV) photon-emitting brachytherapy sources are presented, including the physical characteristics of specific {sup 192}Ir, {sup 137}Cs, and {sup 60}Co source models. Methods: This report has been prepared by the High Energy Brachytherapy Source Dosimetry (HEBD) Working Group. This report includes considerations in the application of the TG-43U1 formalism to high-energy photon-emitting sources with particular attention to phantom size effects, interpolation accuracy dependence on dose calculation grid size, and dosimetry parameter dependence on source active length. Results: Consensus datasets for commercially available high-energy photon sources are provided, along with recommended methods for evaluating these datasets. Recommendations on dosimetry characterization methods, mainly using experimental procedures and Monte Carlo, are established and discussed. Also included are methodological recommendations on detector choice, detector energy response characterization and phantom materials, and measurement specification methodology. Uncertainty analyses are discussed and recommendations for high-energy sources without consensus datasets are given. Conclusions: Recommended consensus datasets for high-energy sources have been derived for sources that were commercially available as of January 2010. Data are presented according to the AAPM TG-43U1 formalism, with modified interpolation and extrapolation techniques of the AAPM TG-43U1S1 report for the 2D anisotropy function and radial dose function.

  2. Remote Sensing of Icy Galilean Moon Surface and Atmospheric Composition Using Low Energy (1 eV-4 keV) Neutral Atom Imaging

    NASA Technical Reports Server (NTRS)

    Collier, M. R.; Sittler, E.; Chornay, D.; Cooper, J. F.; Coplan, M.; Johnson, R. E.

    2004-01-01

    We describe a low energy neutral atom imager suitable for composition measurements Europa and other icy Galilean moons in the Jovian magnetosphere. This instrument employs conversion surface technology and is sensitive to either neutrals converted to negative ions, neutrals converted to positive ions and the positive ions themselves depending on the power supply. On a mission such as the Jupiter Icy Moons Orbiter (JIMO), two back-to-back sensors would be flown with separate power supplies fitted to the neutral atom and iodneutral atom sides. This will allow both remote imaging of 1 eV < E < 4 keV neutrals from icy moon surfaces and atmospheres, and in situ measurements of ions at similar energies in the moon ionospheres and Jovian magnetospheric plasma. The instrument provides composition measurements of the neutrals and ions that enter the spectrometer with a mass resolution dependent on the time-of-flight subsystem and capable of resolving molecules. The lower energy neutrals, up to tens of eV, arise from atoms and molecules sputtered off the moon surfaces and out of the moon atmospheres by impacts of more energetic (keV to MeV) ions from the magnetosphere. Direct Simulation Monte Carlo (DSMC) models are used to convert measured neutral abundances to compositional distributions of primary and trace species in the sputtered surfaces and atmospheres. The escaping neutrals can also be detected as ions after photo- or plasma-ionization and pickup. Higher energy, keV neutrals come from charge exchange of magnetospheric ions in the moon atmospheres and provide information on atmospheric structure. At the jovicentric orbits of the icy moons the presence of toroidal gas clouds, as detected at Europa's orbit, provide M e r opportunities to analyze both the composition of neutrals and ions originating from the moon surfaces, and the characteristics of magnetospheric ions interacting with neutral cloud material. Charge exchange of low energy ions near the moons, and

  3. Ionic Liquids as a Reference Material Candidate for the Quick Performance Check of Energy Dispersive X-ray Spectrometers for the Low Energy Range below 1 keV

    PubMed Central

    2016-01-01

    Ionic liquids (ILs) are proposed as simple and efficient test materials to evaluate the performance of energy dispersive X-ray spectrometers (EDS) in the low energy range below 1 keV. By only one measurement, C Kα, N Kα, O Kα, and F Kα X-ray lines can be excited. Additionally, the S Kα line at 2.3 keV and, particularly, the S L series at 149 eV complete the picture with X-ray lines offered by the selected ILs. The well-known (certifiable) elemental composition of the ILs selected in the present study can be used to check the accuracy of results produced with the available EDS quantification routines in the low energy range, simultaneously, for several low atomic number elements. A comparison with other reference materials in use for testing the performance of EDS in the low energy range is included. PMID:27336962

  4. Determination of neutron spectra within the energy of 1 keV to 1 MeV by means of reactor dosimetry

    SciTech Connect

    Sergeyeva, Victoria; Destouches, Christophe; Lyoussi, Abdallah; Thiollay, Nicolas; Vigneau, Olivier; Korschinek, Gunther; Carcreff, Hubert

    2015-07-01

    The standard procedure for neutron reactor dosimetry is based on neutron irradiation of a target and its post-irradiation analysis by Gamma and/or X-ray spectrometry. Nowadays, the neutron spectra can be easily characterized for thermal and fast energies (respectively 0.025 eV and >1 MeV). In this work we propose a new target and an innovating post-irradiation technique of analysis in order to detect the neutron spectra within the energy of 1 keV to 1 MeV. This article will present the calculations performed for the selection of a suitable nuclear reaction and isotope, the results predicted by simulations, the irradiation campaign that is proposed and the post-irradiation technique of analysis. (authors)

  5. Array-compatible transition-edge sensor microcalorimeter {gamma}-ray detector with 42 eV energy resolution at 103 keV

    SciTech Connect

    Zink, B. L.; Ullom, J. N.; Beall, J. A.; Irwin, K. D.; Doriese, W. B.; Duncan, W. D.; Ferreira, L.; Hilton, G. C.; Horansky, R. D.; Reintsema, C. D.; Vale, L. R.

    2006-09-18

    The authors describe a microcalorimeter {gamma}-ray detector with measured energy resolution of 42 eV full width at half maximum for 103 keV photons. This detector consists of a thermally isolated superconducting transition-edge thermometer and a superconducting bulk tin photon absorber. The absorber is attached with a technique compatible with producing arrays of high-resolution {gamma}-ray detectors. The results of a detailed characterization of the detector, which includes measurements of the complex impedance, detector noise, and time-domain pulse response, suggest that a deeper understanding and optimization of the thermal transport between the absorber and thermometer could significantly improve the energy resolution of future detectors.

  6. Absolute calibration of the Agfa Structurix series films at energies between 2.7 and 6.2 keV.

    PubMed

    Lanier, N E; Cowan, J S

    2014-11-01

    Although photo-emulsion technology is many decades old, x-ray film still remains a key asset for diagnosing hydrodynamic features in High-Energy Density (HED) experiments. For decades, the preferred option had been Kodak's direct exposure film. After its discontinuance in 2004, the push to find alternatives began. In many situations, the Agfa Structurix series offers the most favorable substitute, but being new to the HED community, its characterization was lacking. To remedy this, recent experiments, conducted at Brookhaven's National Synchrotron Light Source, provide absolute, monochromatic calibration data for the Agfa Structurix series films at K-shell backlighter energies between 2.7 and 6.2 keV. Absolute response curves are presented for Agfa D8, D7, D4, D4sc, D3, and D2. Moreover, the transmission of each film type is also measured.

  7. 14-pixel, multiplexed array of gamma-ray microcalorimeters with 47 eV energy resolution at 103 keV

    SciTech Connect

    Doriese, W. B.; Ullom, J. N.; Beall, J. A.; Duncan, W. D.; Ferreira, L.; Hilton, G. C.; Horansky, R. D.; Irwin, K. D.; Mates, J. A. B.; Reintsema, C. D.; Vale, L. R.; Xu, Y.; Zink, B. L.; Rabin, M. W.; Hoover, A. S.; Rudy, C. R.; Vo, D. T.

    2007-05-07

    The authors present a prototype for a high-energy-resolution, high-count-rate, gamma-ray spectrometer intended for nuclear forensics and international nuclear safeguards. The prototype spectrometer is an array of 14 transition-edge-sensor microcalorimeters with an average energy resolution of 47 eV (full width at half maximum) at 103 keV. The resolution of the best pixel is 25 eV. A cryogenic, time-division multiplexer reads out the array. Several important topics related to microcalorimeter arrays are discussed, including cross-talk, the uniformity of detector bias conditions, fabrication of the arrays, and the multiplexed readout. The measurements and calculations demonstrate that a kilopixel array of high-resolution microcalorimeters is feasible.

  8. Multifunctional L1(0) -Mn(1.5)Ga films with ultrahigh coercivity, giant perpendicular magnetocrystalline anisotropy and large magnetic energy product.

    PubMed

    Zhu, Lijun; Nie, Shuaihua; Meng, Kangkang; Pan, Dong; Zhao, Jianhua; Zheng, Houzhi

    2012-08-28

    A new kind of multifunctional L1(0) -Mn(1.5)Ga film is demonstrated for the first time. These MBE-grown epitaxial films exhibit pronounced magnetic properties at room temperature, including ultrahigh perpendicular coercivity up to 42.8 kOe, giant perpendicular magnetic anisotropy with a maximum of 21.7 Merg/cm(3) and large magnetic energy products up to 2.60 MGOe, which allow various applications in ultrahigh density recording, spintronics, and permanent magnets.

  9. 241 Am ( n ,γ) cross section in the neutron energy region between 0.02 eV and 300 keV

    NASA Astrophysics Data System (ADS)

    Jandel, M.; Bredeweg, T. A.; Bond, E. M.; Chadwick, M. B.; Clement, R. R.; Couture, A.; O'Donnell, J. M.; Haight, R. C.; Reifarth, R.; Rundberg, R. S.; Ullmann, J. L.; Vieira, D. J.; Wilhelmy, J. B.; Wouters, J. M.; Macri, R. A.; Wu, C. Y.; Becker, J. A.

    2008-04-01

    The Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL) was used for a neutron capture cross section measurement on 241 Am . The high granularity of the DANCE array (160 BaF2 detectors in a 4π geometry) enables an efficient detection of prompt gamma rays following neutron capture. The preliminary results on the 241 Am ( n ,γ) cross section are presented from 0.02 eV to 300 keV. The cross section at thermal energy E n = 0.0253 eV was determined to be 665±33 barns. Resonance parameters were obtained using the SAMMY7 fit to the measured cross section in the resonance region. Significant discrepancies were found between our results and data evaluations for the first three lowest lying resonances. The cross section for neutrons with E n >l keV agrees well with the ENDF/B-VII.0 and JENDL-3.3 evaluations.

  10. {sup 241}Am(n,{gamma}) cross section in the neutron energy region between 0.02 eV and 300 keV

    SciTech Connect

    Jandel, M.; Bredeweg, T. A.; Bond, E. M.; Chadwick, M. B.; Clement, R. R.; Couture, A.; O' Donnell, J. M.; Haight, R. C.; Reifarth, R.; Rundberg, R. S.; Ullmann, J. L.; Vieira, D. J.; Wilhelmy, J. B.; Wouters, J. M.; Macri, R. A.; Wu, C. Y.; Becker, J. A.

    2008-04-17

    The Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL) was used for a neutron capture cross section measurement on {sup 241}Am. The high granularity of the DANCE array (160 BaF2 detectors in a 4{pi} geometry) enables an efficient detection of prompt gamma rays following neutron capture. The preliminary results on the {sup 241}Am(n,{gamma}) cross section are presented from 0.02 eV to 300 keV. The cross section at thermal energy E{sub n} = 0.0253 eV was determined to be 665{+-}33 barns. Resonance parameters were obtained using the SAMMY7 fit to the measured cross section in the resonance region. Significant discrepancies were found between our results and data evaluations for the first three lowest lying resonances. The cross section for neutrons with E{sub n}>l keV agrees well with the ENDF/B-VII.0 and JENDL-3.3 evaluations.

  11. YIELDS OF IONS AND EXCITED STATES IN NONPOLAR LIQUIDS EXPOSED TO X-RAYS OF 1 TO 30 KEV ENERGY

    SciTech Connect

    HOLROYD,R.A.

    1999-08-18

    When x-rays from a synchrotron source are absorbed in a liquid, the x-ray energy (E{sub x}) is converted by the photoelectric effect into the kinetic energy of the electrons released. For hydrocarbons, absorption by the K-electrons of carbon dominates. Thus the energy of the photoelectron (E{sub pe}) is E{sub x}-E{sub b}, where E{sub b} is the K-shell binding energy of carbon. Additional electrons with energy equal to E{sub b} is released in the Auger process that fills the hole in the K-shell. These energetic electrons will produce many ionizations, excitations and products. The consequences of the high density of ionizations and excitations along the track of the photoelectron and special effects near the K-edge are examined here.

  12. High-energy (100-keV) e-beam lithography applied for fabrication of deep-submicrometer SAW devices on lithium niobate and quartz

    NASA Astrophysics Data System (ADS)

    Kondek, Christine A.; Poli, Louis C.

    1995-05-01

    Fabricating submicron feature size Surface Acoustic Wave (SAW) devices on Lithium Niobate and Quartz allows one to take advantage of their unique piezoelectric material properties and operate at higher frequencies. With the recent availability of high performance, high energy e-beam nanowriter tools such as the Leica/Phillips EBPG-HR5 resident at this facility, SAW devices with very narrow line/space transducer gratings can be investigated. Utilizing very high energy (100 keV) direct write electron beam lithography (EBL), allows for processing of deep submicron features with an associated wider process latitude. This is specially desirable when applying EBL to high average Z materials such as lithium niobate. A previously presented paper demonstrated 400 and 500 nm line/space interdigitated transducer fingers on quartz and lithium niobate substrates. E-Beam lithography (30 keV) was used with two and three level, positive and negative tone processes respectively. In this current work a bilevel positive tone process is used by the authors, and involves first spinning a preparation of (1:1) ZEP-320-37 (Nagase Chemical) positive e-beam resist. A commercially available conductive polymer known as TQV-501 (Nitto Chemical) is then spun onto the wafer and serves as a charge removal vehicle. The TQV-501 film is removed by the development procedure. Xylene is used as the developer. Contact pads and interdigitated transducer elements are realized by e-beam metal deposition and lift off process. We will show a direct write positive tone process for the fabrication of deep submicron (400 nM and smaller) interdigitated transducer gratings on Lithium Niobate and Quartz substrates. An improved process dose latitude is seen because of the reduced expected proximity effect at high beam energy.

  13. Mass attenuation coefficient of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using 16.59 - 25.26 keV photon energy range

    NASA Astrophysics Data System (ADS)

    Mohd Yusof, Mohd Fahmi; Hamid, Puteri Nor Khatijah Abdul; Bauk, Sabar; Hashim, Rokiah; Tajuddin, Abdul Aziz

    2015-04-01

    The Rhizophora spp. particleboards were fabricated using ≤ 104 µm particle size at three different fabrication methods; binderless, steam pre-treated and tannin-added. The mass attenuation coefficient of Rhizophora spp. particleboards were measured using x-ray fluorescent (XRF) photon from niobium, molybdenum, palladium, silver and tin metal plates that provided photon energy between 16.59 to 25.26 keV. The results were compared to theoretical values for water calculated using photon cross-section database (XCOM).The results showed that all Rhizophora spp. particleboards having mass attenuation coefficient close to calculated XCOM for water. Tannin-added Rizophora spp. particleboard was nearest to calculated XCOM for water with χ2 value of 13.008 followed by binderless Rizophora spp. (25.859) and pre-treated Rizophora spp. (91.941).

  14. Observation of lithium pick-up ions in the 5- to 20-keV energy range following the AMPTE solar wind releases

    SciTech Connect

    Moebius, E.; Hovestadt, D.; Klecker, B.; Scholer, M.; Gloeckler, G.; Ipavich, F.M.; Luehr, H.

    1986-02-01

    Newly created 5- to 20-keV lithium ions were observed for limited time periods following the first Active Magnetospheric Particle Tracer Explorers (AMPTE) lithium release in the solar wind on September 11, 1984. The detection of these so-called ''pick-up'' ions by the time-of-flight spectrometer SULEICA (suprathermal energy ionic charge analyzer) on the AMPTE/IRM satellite depends critically on the orientation of the interplanetary magnetic field with respect to the directions of the solar wind and the spin axis of the IRM spacecraft, which was favorable only during the short time when these ions were seen. Our observations are compatible with a shell-like expansion of the Li cloud with velocities of about 2.5 km/s. The signatures by which the artificial pick-up ions are identified can also be used to detect and investigate natural pick-up ions.

  15. Development of 4.5 keV monochromatic X-ray radiography using the high-energy, picosecond LFEX laser

    NASA Astrophysics Data System (ADS)

    Sawada, H.; Fujioka, S.; Hosoda, T.; Zhang, Z.; Arikawa, Y.; Nagatomo, H.; Nishimura, H.; Sunahara, A.; Theobald, W.; Patel, P. K.; Beg, F. N.

    2016-05-01

    Development of a monochromatic x-ray imaging system using a high-energy short- pulse laser LFEX and a spherical crystal is reported. Irradiation of the intense short-pulse laser produces a flash of 4.51 keV Ti K-alpha x-ray while the spherically bent quartz crystal provides a narrow spectral bandwidth and high spatial resolution. This high spatiotemporal imaging technique was applied for recording 2-D monochromatic x-ray images of laser-driven Fast Ignition targets. The results show a sufficiently high spatial resolution to characterize the implosion core, suggesting that the core information extracted from the radiograph images can be used to benchmark a 2-D radiation-hydrodynamic code for accurate hydrodynamic modelling and optimization of FI fuel assembly in the asymmetrical implosion.

  16. Measurement of mass attenuation coefficients of Eremurus-Rhizophora spp. particleboards for X-ray in the 16.63-25.30 keV energy range

    NASA Astrophysics Data System (ADS)

    Tousi, E. T.; Bauk, S.; Hashim, R.; Jaafar, M. S.; Abuarra, A.; Aldroobi, K. S. A.; Al-Jarrah, A. M.

    2014-10-01

    The roots of Eremurus spp. were used as a bio-adhesive in the fabrication of Rhizophora spp. particleboards. The mass attenuation coefficients of Eremurus-Rhizophora spp. particleboard of six samples with two different weight percentages of the Eremurus spp. root (6% and 12%) and three various Rhizophora spp. particle sizes (≤149 μm, 149-500 μm and 500-1000 μm) were determined by using X-ray fluorescence (XRF) photons in 16.63 keV and 25.30 keV of the photon energy range. The results were compared with theoretically calculated mass attenuations using the XCOM computer program for younger-age (breast 1: 75% muscle+25% fat), middle-age (breast 2: 50% muscle+50% fat), and old-age (breast 3: 25% muscle+75% fat) breasts. The results indicated that Eremurus-Rhizophora spp. particleboard is the appropriate suitable phantom in the diagnostic energy region. The mass attenuation coefficient in the low weight percentage of the bio-adhesive and the large Rhizophora spp. particle size were found very close to breast 1. Moreover the mass attenuation coefficient of the sample with high weight percentage of the bio-adhesive and small Rhizophora spp. particle size was found very close to water as a standard material phantom. In addition, the viscosity of dissolved Eremurus spp. root in water could be considerably higher than that of formaldehyde-based adhesives, which affects on some properties such as high strength and high binding.

  17. COCO, a Compton coincidence experiment to study liquid scintillator response in the 1-20 keV energy range

    NASA Astrophysics Data System (ADS)

    Péron, M. N.; Cassette, P.

    1994-12-01

    The use of Liquid Scintillation Counting (LSC) as a fundamental radionuclide standardisation method requires a correct description of the physical phenomena occurring during the LSC process. In that framework, a special point of interest is the description of the liquid scintillator response, especially for low-energy electrons, in a region where this response is known to be non-linear. As there is no simple way to produce monoenergetic electrons in the liquid scintillator, we have simulated these electrons using a Compton interaction coincidence method. Due to the energy conservation law, the selection of the energy of the scattered Compton X-ray photon is equivalent to the selection of the energy of a monoenergetic electron. This paper describes the experimental system and the methods used to analyse the experimental results in order to deduce the statistical distribution of the photons emitted by the scintillator. The effects of some artefacts are discussed, including the accidental coincidences and the influence of cascade Compton interactions.

  18. A satellite-borne ion mass spectrometer for the energy range 0 to 16 keV

    NASA Technical Reports Server (NTRS)

    Balsiger, H.; Eberhardt, P.; Geiss, J.; Ghielmetti, A.; Walker, H. P.; Young, D. T.; Loidl, H.; Rosenbauer, H.

    1976-01-01

    The Ion Composition Experiment (ICE) on GEOS represents the first comprehensive attempt to measure the positive ion composition at high altitudes in the magnetosphere. Due to the heterogeneous nature of the magnetospheric plasma a novel mass spectrometer has been developed to cover the mass per charge range from H-1(+) to beyond Ba-138(+) and the energy per charge range from 0 to 16 keV/e. The ICE consists primarily of a cylindrical electrostatic analyzer followed by a curved analyzer incorporating crossed magnetic and electric fields. This combination has limited angular and energy focusing properties, but it maintains a mass resolution of about 4 over a wide range in energy and mass, sufficient for the objectives of measuring plasmas of both solar and terrestrial origin. High sensitivity and low background should allow measurements of rarer ion constituents down to flux levels of 0.01 ions/sq cm sec ster eV. A sophisticated electronics combined with powerful ground computer and telecommand systems allow for very efficient scanning of the mass-energy space.

  19. Learning to Apply Metrology Principles to the Measurement of X-ray Intensities in the 500 eV to 110 keV Energy Range

    SciTech Connect

    Haugh, M. J.; Pond, T.; Silbernagel, C.; Torres, P.; Marlett, K.; Goldin, F.; Cyr, S.

    2011-02-08

    National Security Technologies, LLC (NSTec), Livermore Operations, has two optical radiation calibration laboratories accredited by “the National Voluntary Laboratories Accreditation Program (NVLAP) which is the accrediting body of” the National Institute of Standards and Technology (NIST), and is now working towards accreditation for its X-ray laboratories. NSTec operates several laboratories with X-ray sources that generate X-rays in the energy range from 50 eV to 115 keV. These X-ray sources are used to characterize and calibrate diagnostics and diagnostic components used by the various national laboratories, particularly for plasma analysis on the Lawrence Livermore National Laboratory (LLNL) National Ignition Facility (NIF). Because X-ray photon flux measurement methods that can be accredited, i.e., traceable to NIST, have not been developed for sources operating in these energy ranges, NSTec, NIST, and the National Voluntary Accreditation Program (NVLAP) together have defined a path toward the development and validation of accredited metrology methods for X-ray energies. The methodology developed for the high energy X-ray (HEX) Laboratory was NSTec’s starting point for X-ray metrology accreditation and will be the basis for the accredited processes in the other X-ray laboratories. This paper will serve as a teaching tool, by way of this example using the NSTec X-ray sources, for the process and methods used in developing an accredited traceable metrology.

  20. Gamma-ray bursts investigations: perspectives for the GAMMA-400 space experiment in the energy range of 100 keV-3 TeV

    NASA Astrophysics Data System (ADS)

    Arkhangelskaja, Irene; Yurkin, Yuri T.; Arkhangelsky, Andrey; Topchiev, Nikolay; Kheymits, Maxim; Runtso, Mikhail; Suchkov, Sergey; Galper, Arkady

    Several thousands of gamma-ray bursts were observed by various experiments, but their sources origin still remains unclear up to now. During several GRBs very high-energy photons were detected both in space and ground-based experiments (up to some tens of GeV and up to some TeV, respectively). The GAMMA-400 future space experiment consists of the GAMMA-400 gamma-ray telescope to detect gammas in the energy range of 100 MeV - 3 TeV and the KONUS-FG system to detect gamma-ray bursts in the range of 100 keV - 10 MeV similar to the KONUS/WIND instrument. The GAMMA-400 gamma-ray telescope will have the angular resolution of 0.02 deg for E > 100 GeV, the energy resolution of 2% for E > 10 GeV, time resolution of ˜ 0.1 ms and allow us together with KONUS-FG to investigate GRBs spectra and temporal profiles in details in the wide energy range.

  1. Zernike-type phase contrast X-ray microscopy at 4 keV photon energy with 60 nm resolution

    NASA Astrophysics Data System (ADS)

    Neuhäusler, Ulrich; Schneider, Gerd

    2004-05-01

    X-ray microscopy in the multi-keV photon energy range offers unique possibilities to study thick dense samples with high spatial resolution. When employing a high numerical aperture (N.A.) condenser zone plate sample illumination in combination with a high resolution micro zone plate objective lens, a spatial resolution of currently 60 nm is achieved. Since the absorption becomes smaller with increasing photon energy, phase contrast imaging overcomes the limitation for imaging weakly absorbing structures in amplitude contrast mode. We report here on X-ray microscopy of advanced microelectronic devices imaged in Zernike phase contrast mode. While the amplitude contrast between copper and silicon dioxide in these samples is only 7 %, negative as well as positive phase contrast were demonstrated with a contrast of 40 % and 45 %, respectively.

  2. A multilayer grating with a novel layer structure for a flat-field spectrograph attached to transmission electron microscopes in energy region of 2-4 keV

    SciTech Connect

    Imazono, T.; Koike, M.; Koeda, M.; Nagano, T.; Sasai, H.; Oue, Y.; Yonezawa, Z.; Kuramoto, S.; Terauchi, M.; Takahashi, H.; Handa, N.; Murano, T.

    2012-05-17

    A multilayer mirror with a novel layer structure to uniformly enhance the reflectivity in a few keV energy range at a fixed angle of incidence is invented and applied to a multilayer grating for use in a flat-field spectrograph attached to a conventional electron microscope. The diffraction efficiency of the fabricated multilayer grating having the new layer structure is evaluated at the angle of incidence of 88.65 deg. in the energy region of 2.1-4.0 keV. It is shown that the multilayer grating is effective to uniformly enhance the diffraction efficiency and able to be practically used in this energy region.

  3. Observations of the scatter-free solar-flare electrons in the energy range 20-1000 keV

    NASA Technical Reports Server (NTRS)

    Wang, J. R.; Fisk, L. A.; Lin, R. P.

    1971-01-01

    Observations of the scatter-free electron events from solar active region McMath No. 8905 are presented. The measurements were made on Explorer 33 satellite. The data show that more than 80% of the electrons from these events undergo no or little scattering and that these electrons travel only approximately 1.5 a.u. between the sun and the earth. The duration of these events cannot be accounted fully by velocity dispersion alone. It is suggested that these electrons could be continuously injected into interplanetary medium for a time interval of approximately 2 to 3 minutes. Energy spectra of these electrons are discussed.

  4. Reevaluation of 58Ni and 60Ni Resonance Parameters in the Energy Range Thermal to 800 keV

    SciTech Connect

    Derrien, Herve; Leal, Luiz C; Guber, Klaus H; Wiarda, Dorothea; Arbanas, Goran

    2009-01-01

    The previous 58Ni and 60Ni set of resonance parameters (ENDF/B-VII-0, JEFF-3, etc.) was based on the SAMMY analysis of Oak Ridge National Laboratory neutron transmission, scattering cross section and capture cross section measurements by C. M. Perey et al. The present results were obtained by adding to the SAMMY experimental data base the capture cross sections measured recently at the Oak Ridge Linear Electron Accelerator by Guber et al. and the Geel Electron Linear Accelerator very high-resolution neutron transmission measurements performed by Brusegan et al. A complete resonance parameter covariance matrix (RPCM) was obtained from the SAMMY analysis of the experimental database. The data sets were made consistent, when needed, by adjusting the neutron energy scales, the normalization coefficients, and the background corrections. The RPCM allows the calculation of the cross section uncertainties due mainly to statistical errors in the experimental data. The systematic uncertainties of the experimental data, estimated from the preliminary analyses of the experimental database, were taken into account in the cross section covariance matrix (CSCM) for total, scattering, and capture cross sections. The diagonal elements of the CSCM were obtained by quadratic combination of the different components of the uncertainties. Because of a lack of experimental information, the energy correlations were not obtained, and a value of 0.5 was arbitrarily taken for all the CSCM nondiagonal elements.

  5. Ion Beam Materials Analysis and Modifications at keV to MeV Energies at the University of North Texas

    NASA Astrophysics Data System (ADS)

    Rout, Bibhudutta; Dhoubhadel, Mangal S.; Poudel, Prakash R.; Kummari, Venkata C.; Lakshantha, Wickramaarachchige J.; Manuel, Jack E.; Bohara, Gyanendra; Szilasi, Szabolcs Z.; Glass, Gary A.; McDaniel, Floyd D.

    2014-02-01

    The University of North Texas (UNT) Ion Beam Modification and Analysis Laboratory (IBMAL) has four particle accelerators including a National Electrostatics Corporation (NEC) 9SDH-2 3 MV tandem Pelletron, a NEC 9SH 3 MV single-ended Pelletron, and a 200 kV Cockcroft-Walton. A fourth HVEC AK 2.5 MV Van de Graaff accelerator is presently being refurbished as an educational training facility. These accelerators can produce and accelerate almost any ion in the periodic table at energies from a few keV to tens of MeV. They are used to modify materials by ion implantation and to analyze materials by numerous atomic and nuclear physics techniques. The NEC 9SH accelerator was recently installed in the IBMAL and subsequently upgraded with the addition of a capacitive-liner and terminal potential stabilization system to reduce ion energy spread and therefore improve spatial resolution of the probing ion beam to hundreds of nanometers. Research involves materials modification and synthesis by ion implantation for photonic, electronic, and magnetic applications, micro-fabrication by high energy (MeV) ion beam lithography, microanalysis of biomedical and semiconductor materials, development of highenergy ion nanoprobe focusing systems, and educational and outreach activities. An overview of the IBMAL facilities and some of the current research projects are discussed.

  6. Angular distribution of thick-target bremsstrahlung produced by electrons with initial energies ranging from 10 to 20 keV incident on Ag

    SciTech Connect

    Gonzales, D.; Cavness, B.; Williams, S.

    2011-11-15

    Experimental results are presented comparing the intensities of the bremsstrahlung produced by electrons with initial energies ranging from 10 to 20 keV incident on a thick Ag target, measured at forward angles in the range of 0 degree sign to 55 degree sign . When the data are corrected for attenuation due to photon absorption within the target, the results indicate that the detected radiation is distributed anisotropically only at photon energies k that are approximately equal to the initial energy of the incident electrons E{sub 0}. The results of our experiments suggest that, as k/E{sub 0}{yields} 0, the detected radiation essentially becomes isotropic due primarily to the scattering of electrons within the target. A comparison to the theory of Kissel et al.[At. Data Nucl. Data Tables 28, 381 (1983)] suggests that the angular distribution of bremsstrahlung emitted by electrons incident on thick targets is similar to the angular distribution of bremsstrahlung emitted by electrons incident on free-atom targets only when k/E{sub 0}{approx_equal} 1. The experimental data also are in approximate agreement with the angular distribution predictions of the Monte Carlo program penelope.

  7. Efficient Nd3+→Yb3+ energy transfer processes in high phonon energy phosphate glasses for 1.0 μm Yb3+ laser

    NASA Astrophysics Data System (ADS)

    Rivera-López, F.; Babu, P.; Basavapoornima, Ch.; Jayasankar, C. K.; Lavín, V.

    2011-06-01

    Efficient Nd3+→Yb3+ resonant and phonon-assisted energy transfer processes have been observed in phosphate glasses and have been studied using steady-state and time-resolved optical spectroscopies. Results indicate that the energy transfer occurs via nonradiative electric dipole-dipole processes and is enhanced with the concentration of Yb3+ acceptor ions, having an efficiency higher than 75% for the glass doped with 1 mol% of Nd2O3 and 4 mol% of Yb2O3. The luminescence decay curves show a nonexponential character and the energy transfer microscopic parameter calculated with the Inokuti-Hirayama model gives a value of 240 × 10-40 cm6 s-1, being one of the highest reported in the literature for Nd3+-Yb3+ co-doped matrices. From the steady-state experimental absorption and emission cross-sections, a general expression for estimating the microscopic energy transfer parameter is proposed based upon the theoretical methods developed by Miyakawa and Dexter and Tarelho et al. This expression takes into account all the resonant mechanisms involved in an energy transfer processes together with other phonon-assisted nonvanishing overlaps. The value of the Nd3+→Yb3+ energy transfer microscopic parameter has been calculated to be 200 × 10-40 cm6 s-1, which is in good agreement with that obtained from the Inokuti-Hirayama fitting. These results show the importance of the nonresonant phonon-assisted Nd3+→Yb3+ energy transfer processes and the great potential of these glasses as active matrices in the development of multiple-pump-channel Yb3+ lasers.

  8. Atom penetration from a thin film into the substrate during sputtering by polyenergetic Ar{sup +} ion beam with mean energy of 9.4 keV

    SciTech Connect

    Kalin, B.A.; Gladkov, V.P.; Volkov, N.V.; Sabo, S.E.

    1995-12-31

    Penetration of alien atoms (Be, Ni) into Be, Al, Zr, Si and diamond was investigated under Ar{sup +} ion bombardment of samples having thermally evaporated films of 30--50 nm. Sputtering was carried out using a wide energy spectrum beam of Ar{sup +} ions of 9.4 keV to dose D = 1 {times} 10{sup 16}--10{sup 19} ion/cm{sup 2}. Implanted atom distribution in the targets was measured by Rutherford backscattering spectrometry (RBS) of H{sup +} and He{sup +} ions with energy of 1.6 MeV as well as secondary ion mass-spectrometry (SIMS). During the bombardment, the penetration depth of Ar atoms increases with dose linearly. This depth is more than 3--20 times deeper than the projected range of bombarding ions and recoil atoms. This is a deep action effect. The analysis shows that the experimental data for foreign atoms penetration depth are similar to the data calculated for atom migration through the interstitial site in a field of internal (lateral) compressive stresses created in the near-surface layer of the substrate as a result of implantation. Under these experimental conditions atom ratio r{sub i}/r{sub m} (r{sub i} -- radius of dopant, r{sub m} -- radius target of substrate) can play a principal determining role.

  9. 330-keV electron line in e sup + +Th interactions

    SciTech Connect

    Sakai, M.; Fujita, Y.; Imamura, M.; Omata, K.; Ohya, S.; Muto, S.; Miura, T.; Gono, Y.; Chojnacki, S. Niigata University, Niigata National Laboratory for High Energy Physics, Tsukuba Institute for Physical and Chemical Research, Wako-shi, Saitama-ken Accelerator Laboratory, Warsaw University, Warsaw )

    1991-09-01

    The previously reported 330.8{plus minus}1.0-keV electron line in {ital e}{sup +}+Th interactions has been reinvestigated to confirm its existence. We have made a definite observation of the relevant peak with an energy of 330.1{plus minus}0.3 keV, a fullwidth at half maximum of less than 1.7{plus minus}0.7 keV and a cross section of 160(1{plus minus}0.19{plus minus}0.25) mb. We have assigned the generation site of the electrons to the Th target by comparing the energy shift and the shape change of the line with those of the neighboring conversion lines in the spectra taken under different scattering conditions.

  10. Low energy (10eV to 10 keV) equatorial particle fluxes and soft particle fluxes near the equator

    NASA Technical Reports Server (NTRS)

    Winningham, J. D.; Heikkila, W. J.

    1974-01-01

    Several spectra are shown that represent one rotation of ISIS-1. Spectra 1, 2, 3, represent particles moving down the field line into northern ionosphere and spectra 4, 5, 6 represent particles moving up field lines towards the magnetic equator. The former are direct fluxes and the latter are albedo fluxes. The spectra observed are remarkably similar to these observed in the auroral zone. The direct fluxes exhibit a relative maximum in the few keV range and the albedo a power low spectrum with increased fluxes at low energies. Examination of concurrent topside sounder data on ISIS-1 revealed a positive correlation between a region of turbulent ionosphere and particle fluxes. This ionospheric condition is referred to as equatorial spread F and has been studied extensively with bottomside ionospheric sounders and backscatter radars. The perigee of ISIS crossed the magnetic equator at four local times (0400, 1000, 1600, 2100) during the lifetime of the particle spectrometer. No fluxes were observed at 0400 and 1000 local time. At 1600 a few instances of particles were observed. At 2100 essentially all passes included detectable equatorial fluxes. This is in agreement with the frequency of occurence of equatorial spread F.

  11. Local structures of electrons with energies of hundreds of keV in the inner belt and the slot region observed from the Vernov satellite

    NASA Astrophysics Data System (ADS)

    Kovtyukh, A. S.; Myagkova, I. N.; Bogomolov, A. V.; Bogomolov, V. V.; Panasyuk, M. I.; Svertilov, S. I.

    2016-11-01

    The structure and dynamics of electron fluxes of subrelativistic energies in the range 235-300 keV at L < 4 during December 3-8, 2014, are analyzed according to the RELEC instrument onboard the Vernov satellite. Sharp changes in the parameters of the solar wind and the IMF were detected on December 6, but they did not lead to a magnetic storm. However, after the event of December 6, subrelativistic electron fluxes in the inner belt and the slot region were enhanced and structured. The dynamics of electron fluxes in the local transient bursts at L 1.5-1.7 is considered in detail. It is shown that these bursts are associated with the development of the cyclotron instability in the tops of magnetic flux tubes near the inner belt maximum. The electron anisotropic index is estimated in these bursts. It is shown that in the beginning these bursts are anisotropic and that they become isotropic as the decay proceeds. The most likely chain of physical mechanisms that could lead to variations in electron fluxes of the inner belt described in this paper is presented. For the first time, the topological effects in stationary distributions of the electrons of the inner belt observed at low altitudes in the South Atlantic Anomaly region are explained.

  12. Saturated ablation in metal hydrides and acceleration of protons and deuterons to keV energies with a soft-x-ray laser

    NASA Astrophysics Data System (ADS)

    Andreasson, J.; Iwan, B.; Andrejczuk, A.; Abreu, E.; Bergh, M.; Caleman, C.; Nelson, A. J.; Bajt, S.; Chalupsky, J.; Chapman, H. N.; Fäustlin, R. R.; Hajkova, V.; Heimann, P. A.; Hjörvarsson, B.; Juha, L.; Klinger, D.; Krzywinski, J.; Nagler, B.; Pálsson, G. K.; Singer, W.; Seibert, M. M.; Sobierajski, R.; Toleikis, S.; Tschentscher, T.; Vinko, S. M.; Lee, R. W.; Hajdu, J.; Tîmneanu, N.

    2011-01-01

    Studies of materials under extreme conditions have relevance to a broad area of research, including planetary physics, fusion research, materials science, and structural biology with x-ray lasers. We study such extreme conditions and experimentally probe the interaction between ultrashort soft x-ray pulses and solid targets (metals and their deuterides) at the FLASH free-electron laser where power densities exceeding 1017 W/cm2 were reached. Time-of-flight ion spectrometry and crater analysis were used to characterize the interaction. The results show the onset of saturation in the ablation process at power densities above 1016 W/cm2. This effect can be linked to a transiently induced x-ray transparency in the solid by the femtosecond x-ray pulse at high power densities. The measured kinetic energies of protons and deuterons ejected from the surface reach several keV and concur with predictions from plasma-expansion models. Simulations of the interactions were performed with a nonlocal thermodynamic equilibrium code with radiation transfer. These calculations return critical depths similar to the observed crater depths and capture the transient surface transparency at higher power densities.

  13. Saturated ablation in metal hydrides and acceleration of protons and deuterons to keV energies with a soft-x-ray laser.

    PubMed

    Andreasson, J; Iwan, B; Andrejczuk, A; Abreu, E; Bergh, M; Caleman, C; Nelson, A J; Bajt, S; Chalupsky, J; Chapman, H N; Fäustlin, R R; Hajkova, V; Heimann, P A; Hjörvarsson, B; Juha, L; Klinger, D; Krzywinski, J; Nagler, B; Pálsson, G K; Singer, W; Seibert, M M; Sobierajski, R; Toleikis, S; Tschentscher, T; Vinko, S M; Lee, R W; Hajdu, J; Tîmneanu, N

    2011-01-01

    Studies of materials under extreme conditions have relevance to a broad area of research, including planetary physics, fusion research, materials science, and structural biology with x-ray lasers. We study such extreme conditions and experimentally probe the interaction between ultrashort soft x-ray pulses and solid targets (metals and their deuterides) at the FLASH free-electron laser where power densities exceeding 10(17) W/cm(2) were reached. Time-of-flight ion spectrometry and crater analysis were used to characterize the interaction. The results show the onset of saturation in the ablation process at power densities above 10(16) W/cm(2). This effect can be linked to a transiently induced x-ray transparency in the solid by the femtosecond x-ray pulse at high power densities. The measured kinetic energies of protons and deuterons ejected from the surface reach several keV and concur with predictions from plasma-expansion models. Simulations of the interactions were performed with a nonlocal thermodynamic equilibrium code with radiation transfer. These calculations return critical depths similar to the observed crater depths and capture the transient surface transparency at higher power densities.

  14. Indico 1.0

    NASA Astrophysics Data System (ADS)

    Gonzalez Lopez, J. B.; Avilés, A.; Baron, T.; Ferreira, P.; Kolobara, B.; Pugh, M. A.; Resco, A.; Trzaskoma, J. P.

    2014-06-01

    Indico has evolved into the main event organization software, room booking tool and collaboration hub for CERN. The growth in its usage has only accelerated during the past 9 years, and today Indico holds more that 215,000 events and 1,100,000 files. The growth was also substantial in terms of functionalities and improvements. In the last year alone, Indico has matured considerably in 3 key areas: enhanced usability, optimized performance and additional features, especially those related to meeting collaboration. Along the course of 2012, much activity has centred around consolidating all this effort and investment into "version 1.0", recently released in 2013.Version 1.0 brings along new features, such as the Microsoft Exchange calendar synchronization for participants, many new and clean interfaces (badges and poster generation, list of contributions, abstracts, etc) and so forth. But most importantly, it brings a message: Indico is now stable, consolidated and mature after more than 10 years of non-stop development. This message is addressed not only to CERN users but also to the many organisations, in or outside HEP, which have already installed the software, and to others who might soon join this community. In this document, we describe the current state of the art of Indico, and how it was built. This does not mean that the Indico software is complete, far from it! We have plenty of new ideas and projects that we are working on and which we have shared during CHEP 2013.

  15. Absolute Energy Calibration of X-ray TESs with 0.04 eV Uncertainty at 6.4 keV in a Hadron-Beam Environment

    NASA Astrophysics Data System (ADS)

    Tatsuno, H.; Doriese, W. B.; Bennett, D. A.; Curceanu, C.; Fowler, J. W.; Gard, J.; Gustafsson, F. P.; Hashimoto, T.; Hayano, R. S.; Hays-Wehle, J. P.; Hilton, G. C.; Iliescu, M.; Ishimoto, S.; Itahashi, K.; Iwasaki, M.; Kuwabara, K.; Ma, Y.; Marton, J.; Noda, H.; O'Neil, G. C.; Okada, S.; Outa, H.; Reintsema, C. D.; Sato, M.; Schmidt, D. R.; Shi, H.; Suzuki, K.; Suzuki, T.; Uhlig, J.; Ullom, J. N.; Widmann, E.; Yamada, S.; Zmeskal, J.; Swetz, D. S.

    2016-08-01

    A performance evaluation of superconducting transition-edge sensors (TESs) in the environment of a pion beam line at a particle accelerator is presented. Averaged across the 209 functioning sensors in the array, the achieved energy resolution is 5.2 eV FWHM at Co K_{α } (6.9 keV) when the pion beam is off and 7.3 eV at a beam rate of 1.45 MHz. Absolute energy uncertainty of ± 0.04 eV is demonstrated for Fe K_{α } (6.4 keV) with in-situ energy calibration obtained from other nearby known X-ray lines. To achieve this small uncertainty, it is essential to consider the non-Gaussian energy response of the TESs and thermal cross-talk pile-up effects due to charged particle hits in the silicon substrate of the TES array.

  16. Transmission sputtering of gold thin films by low-energy (< 1 keV) xenon ions. I. The system and the measurement

    NASA Astrophysics Data System (ADS)

    Ayrault, Guy; Seidman, David N.

    1982-10-01

    A novel system for direct measurement of the transmission-sputtering yields of ion-irradiated thin films is described. The system was specifically designed for the study of the transmission sputtering caused by low-energy (<1 keV) xenon ions. The xenon ion beam employed is first mass-analyzed in a specially constructed corssed magnetic- and electric-field mass spectrometer; this analyzer eliminates all energetic neutral and singly charged ions of mass less than 40 amu; it is also expected that ≤2% of the xenon ions which actually reach a specimen are doubly charged. The analyzed xenon ion beam is made to impinge on a gold thin film (˜100-500 Å thick) which is mounted in a JEM 200 transmission electron-microscope holder. The temperature of the specimen can be varied between ˜25 and 300 K employing a continuous transfer liquid-helium cryostat. The particles (atoms or ions) ejected from the unirradiated surface of the gold thin film are detected by two channeltron electron-multiplier arrays (CEMA) in the Chevron configuration; the Chevron detector is able to detect individual transmission-sputtered particles when operated in the saturated mode. To further enhance resolution, the electron cascades (produced by the CEMA), are amplified and shaped electronically into uniform square pulses. The shaped signals are detected with an Ithaco 391A lock-in amplifier (LIA). With the aid of a ratiometer feature in the LIA, we are able to measure directly the ratio of the transmission-sputtered current It to the incident ion current Ib; for Ibn=1 μA cm-2, a ratio of It/Ib as small as 1×10-9 has been measured. A detailed discussion of the calibration procedure and the experimental errors, involved in this technique, are also presented.

  17. Calculations of photo-induced X-ray production cross-sections in the energy range 1-150 keV and average fluorescence yields for Zn, Cd and Hg

    NASA Astrophysics Data System (ADS)

    Sampaio, J. M.; Guerra, M.; Parente, F.; Madeira, T. I.; Indelicato, P.; Santos, J. P.; Marques, J. P.

    2016-09-01

    In this paper, we calculate the K-, L- and M-shells X-ray production, and X-ray fluorescence cross-sections after photo-induced ionization, for Zn, Cd, and Hg, and for incident photon energy range from 1 to 150 keV. For this purpose, the corresponding average fluorescence yields for Zn, Cd, and Hg as well as the photoionization cross-sections were calculated using the Dirac-Fock method. Subshell fluorescence, intrashell and intershell yields are obtained consistently from radiative and radiationless transitions calculated in the exact same method. A comprehensive account of the relations between the X-ray production, X-ray fluorescence cross-sections and the photoionization cross-sections and these yields is presented. Comparisons are made with results from other authors. The obtained values for the photoionization cross-sections are in good agreement with the widely used data of Scofield in the studied energy range. However our results for the X-ray fluorescence cross sections seem to favor some data relatively to others. The energy dependence of the average fluorescence yields is discussed, in particular, the reliability of extrapolated data for lighter elements from measurements and calculations in heavier elements above the inner shell absorption edges is questioned. Tabulated data on photoionization and X-ray production cross-sections are presented for the incident photon energy range 1-150 keV in steps of 1 keV.

  18. Neutron physics of the Re/Os clock. II. The (n,n{sup '}) cross section of {sup 187}Os at 30 keV neutron energy

    SciTech Connect

    Mosconi, M.; Heil, M.; Kaeppeler, F.; Plag, R.; Mengoni, A.

    2010-07-15

    The inelastic neutron-scattering cross section of {sup 187}Os has been determined in a time-of-flight experiment at the Karlsruhe 3.7-MV Van de Graaff accelerator. An almost monoenergetic beam of 30-keV neutrons was produced at the threshold of the {sup 7}Li(p,n){sup 7}Be reaction. Information on the inelastic channel is required for reliable calculations of the so-called stellar enhancement factor, by which the laboratory cross section of {sup 187}Os must be corrected in order to account for the thermal population of low-lying excited states at the temperatures of s-process nucleosynthesis, in particular of the important state at 9.75 keV. This correction represents a crucial step in the interpretation of the {sup 187}Os/{sup 187}Re pair as a cosmochronometer.

  19. Energy-resolved collision-induced dissociation studies of 1,10-phenanthroline complexes of the late first-row divalent transition metal cations: determination of the third sequential binding energies.

    PubMed

    Nose, Holliness; Chen, Yu; Rodgers, M T

    2013-05-23

    The third sequential binding energies of the late first-row divalent transition metal cations to 1,10-phenanthroline (Phen) are determined by energy-resolved collision-induced dissociation (CID) techniques using a guided ion beam tandem mass spectrometer. Five late first-row transition metal cations in their +2 oxidation states are examined including: Fe(2+), Co(2+), Ni(2+), Cu(2+), and Zn(2+). The kinetic energy dependent CID cross sections for loss of an intact Phen ligand from the M(2+)(Phen)3 complexes are modeled to obtain 0 and 298 K bond dissociation energies (BDEs) after accounting for the effects of the internal energy of the complexes, multiple ion-neutral collisions, and unimolecular decay rates. Electronic structure theory calculations at the B3LYP, BHandHLYP, and M06 levels of theory are employed to determine the structures and theoretical estimates for the first, second, and third sequential BDEs of the M(2+)(Phen)x complexes. B3LYP was found to deliver results that are most consistent with the measured values. Periodic trends in the binding of these complexes are examined and compared to the analogous complexes to the late first-row monovalent transition metal cations, Co(+), Ni(+), Cu(+), and Zn(+), previously investigated.

  20. Studies of total bremsstrahlung in thick targets of Al, Ti, Sn and Pb for 90Sr beta particles in the photon energy region of 1-100 keV

    NASA Astrophysics Data System (ADS)

    Singh, Amrit; Dhaliwal, A. S.

    2016-02-01

    Total bremsstrahlung (BS) spectra in thick targets of Al, Ti, Sn and Pb produced by beta emitter 90Sr (End point energy=546 keV) are studied in the photon energy range of 1-100 keV. The experimentally measured BS spectra are compared with the theoretical spectral distributions calculated from Elwert corrected (non relativistic) Bethe-Heitler [EBH] theory, modified Elwert factor (relativistic) Bethe-Heitler [Fmod BH] theory for ordinary bremsstrahlung (OB) and the Avdonina and Pratt [Fmod BH+PB] theory, which include the contribution of polarization bremsstrahlung (PB) into OB. The present results are indicating the correctness of Fmod BH+PB theory in the low energy region, where PB dominates into the BS, but at the middle and higher photon energy region of the bremsstrahlung spectrum, the Fmod BH theory is more close to the experimental results. The description of the bremsstrahlung process in stripped atom (SA) approximation, which indicates the suppression of the bremsstrahlung at higher energy ends due to the production of PB in the low energy region, needs further considerations. Hence, the present measurements for BS for different target materials indicates that the considerations of the screening effects along with other secondary effects during the interaction of incident electrons with the target nuclei are important while describing the production of bremsstrahlung, particularly for the higher energy regions.

  1. Neutron capture cross section measurement of 238U at the CERN n_TOF facility in the energy region from 1 eV to 700 keV

    NASA Astrophysics Data System (ADS)

    Mingrone, F.; Massimi, C.; Vannini, G.; Colonna, N.; Gunsing, F.; Žugec, P.; Altstadt, S.; Andrzejewski, J.; Audouin, L.; Barbagallo, M.; Bécares, V.; Bečvář, F.; Belloni, F.; Berthoumieux, E.; Billowes, J.; Bosnar, D.; Brugger, M.; Calviani, M.; Calviño, F.; Cano-Ott, D.; Carrapiço, C.; Cerutti, F.; Chiaveri, E.; Chin, M.; Cortés, G.; Cortés-Giraldo, M. A.; Diakaki, M.; Domingo-Pardo, C.; Duran, I.; Dressler, R.; Eleftheriadis, C.; Ferrari, A.; Fraval, K.; Ganesan, S.; García, A. R.; Giubrone, G.; Gonçalves, I. F.; González-Romero, E.; Griesmayer, E.; Guerrero, C.; Hernández-Prieto, A.; Jenkins, D. G.; Jericha, E.; Kadi, Y.; Käppeler, F.; Karadimos, D.; Kivel, N.; Koehler, P.; Kokkoris, M.; Krtička, M.; Kroll, J.; Lampoudis, C.; Langer, C.; Leal-Cidoncha, E.; Lederer, C.; Leeb, H.; Leong, L. S.; Lo Meo, S.; Losito, R.; Mallick, A.; Manousos, A.; Marganiec, J.; Martínez, T.; Mastinu, P. F.; Mastromarco, M.; Mendoza, E.; Mengoni, A.; Milazzo, P. M.; Mirea, M.; Mondalaers, W.; Paradela, C.; Pavlik, A.; Perkowski, J.; Plompen, A.; Praena, J.; Quesada, J. M.; Rauscher, T.; Reifarth, R.; Riego, A.; Robles, M. S.; Rubbia, C.; Sabaté-Gilarte, M.; Sarmento, R.; Saxena, A.; Schillebeeckx, P.; Schmidt, S.; Schumann, D.; Tagliente, G.; Tain, J. L.; Tarrío, D.; Tassan-Got, L.; Tsinganis, A.; Valenta, S.; Variale, V.; Vaz, P.; Ventura, A.; Vermeulen, M. J.; Vlachoudis, V.; Vlastou, R.; Wallner, A.; Ware, T.; Weigand, M.; Weiß, C.; Wright, T.; n TOF Collaboration

    2017-03-01

    The aim of this work is to provide a precise and accurate measurement of the 238U(n ,γ ) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behavior of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross section of 238U should be further reduced to 1-3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission. The results of one of these 238U(n ,γ ) measurements performed at the n_TOF CERN facility are presented in this work. The γ -ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.

  2. Comparison of simulated and measured spectra from an X-ray tube for the energies between 20 and 35 keV

    NASA Astrophysics Data System (ADS)

    Yücel, M.; Emirhan, E.; Bayrak, A.; Ozben, C. S.; Yücel, E. Barlas

    2015-11-01

    Design and production of a simple and low cost X-ray imaging system that can be used for light industrial applications was targeted in the Nuclear Physics Laboratory of Istanbul Technical University. In this study, production, transmission and detection of X-rays were simulated for the proposed imaging device. OX/70-P dental tube was used and X-ray spectra simulated by Geant4 were validated by comparison with X-ray spectra measured between 20 and 35 keV. Relative detection efficiency of the detector was also determined to confirm the physics processes used in the simulations. Various time optimization tools were performed to reduce the simulation time.

  3. Investigation of the effective atomic numbers of dosimetric materials for electrons, protons and alpha particles using a direct method in the energy region 10 keV-1 GeV: a comparative study.

    PubMed

    Kurudirek, Murat; Aksakal, Oğuz; Akkuş, Tuba

    2015-11-01

    A direct method has been used for the first time, to compute effective atomic numbers (Z eff) of water, air, human tissues, and some organic and inorganic compounds, for total electron proton and alpha particle interaction in the energy region 10 keV-1 GeV. The obtained values for Z eff were then compared to those obtained using an interpolation procedure. In general, good agreement has been observed for electrons, and the difference (%) in Z eff between the results of the direct and the interpolation method was found to be <10 % for all materials, in the energy range from 10 keV to 1 MeV. More specifically, results of the two methods were found to agree well (Dif. <10 %) for air, calcium fluoride, kapton polyimide film, paraffin wax and plastic scintillator in the entire energy region with respect to the total electron interaction. On the other hand, values for Z eff calculated using both methods for protons and alpha particles generally agree with each other in the high-energy region above 10 MeV.

  4. Evaluating the performance of land surface model ORCHIDEE-CAN v1.0 on water and energy flux estimation with a single- and multi-layer energy budget scheme

    NASA Astrophysics Data System (ADS)

    Chen, Yiying; Ryder, James; Bastrikov, Vladislav; McGrath, Matthew J.; Naudts, Kim; Otto, Juliane; Ottlé, Catherine; Peylin, Philippe; Polcher, Jan; Valade, Aude; Black, Andrew; Elbers, Jan A.; Moors, Eddy; Foken, Thomas; van Gorsel, Eva; Haverd, Vanessa; Heinesch, Bernard; Tiedemann, Frank; Knohl, Alexander; Launiainen, Samuli; Loustau, Denis; Ogée, Jérôme; Vessala, Timo; Luyssaert, Sebastiaan

    2016-09-01

    Canopy structure is one of the most important vegetation characteristics for land-atmosphere interactions, as it determines the energy and scalar exchanges between the land surface and the overlying air mass. In this study we evaluated the performance of a newly developed multi-layer energy budget in the ORCHIDEE-CAN v1.0 land surface model (Organising Carbon and Hydrology In Dynamic Ecosystems - CANopy), which simulates canopy structure and can be coupled to an atmospheric model using an implicit coupling procedure. We aim to provide a set of acceptable parameter values for a range of forest types. Top-canopy and sub-canopy flux observations from eight sites were collected in order to conduct this evaluation. The sites crossed climate zones from temperate to boreal and the vegetation types included deciduous, evergreen broad-leaved and evergreen needle-leaved forest with a maximum leaf area index (LAI; all-sided) ranging from 3.5 to 7.0. The parametrization approach proposed in this study was based on three selected physical processes - namely the diffusion, advection, and turbulent mixing within the canopy. Short-term sub-canopy observations and long-term surface fluxes were used to calibrate the parameters in the sub-canopy radiation, turbulence, and resistance modules with an automatic tuning process. The multi-layer model was found to capture the dynamics of sub-canopy turbulence, temperature, and energy fluxes. The performance of the new multi-layer model was further compared against the existing single-layer model. Although the multi-layer model simulation results showed few or no improvements to both the nighttime energy balance and energy partitioning during winter compared with a single-layer model simulation, the increased model complexity does provide a more detailed description of the canopy micrometeorology of various forest types. The multi-layer model links to potential future environmental and ecological studies such as the assessment of in

  5. Energy-dependent dynamics of keV to MeV electrons in the inner zone, outer zone, and slot regions.

    PubMed

    Reeves, Geoffrey D; Friedel, Reiner H W; Larsen, Brian A; Skoug, Ruth M; Funsten, Herbert O; Claudepierre, Seth G; Fennell, Joseph F; Turner, Drew L; Denton, Mick H; Spence, Harlan E; Blake, J Bernard; Baker, Daniel N

    2016-01-01

    We present observations of the radiation belts from the Helium Oxygen Proton Electron and Magnetic Electron Ion Spectrometer particle detectors on the Van Allen Probes satellites that illustrate the energy dependence and L shell dependence of radiation belt enhancements and decays. We survey events in 2013 and analyze an event on 1 March in more detail. The observations show the following: (a) at all L shells, lower energy electrons are enhanced more often than higher energies; (b) events that fill the slot region are more common at lower energies; (c) enhancements of electrons in the inner zone are more common at lower energies; and (d) even when events do not fully fill the slot region, enhancements at lower energies tend to extend to lower L shells than higher energies. During enhancement events the outer zone extends to lower L shells at lower energies while being confined to higher L shells at higher energies. The inner zone shows the opposite with an outer boundary at higher L shells for lower energies. Both boundaries are nearly straight in log(energy) versus L shell space. At energies below a few 100 keV, radiation belt electron penetration through the slot region into the inner zone is commonplace, but the number and frequency of "slot filling" events decreases with increasing energy. The inner zone is enhanced only at energies that penetrate through the slot. Energy- and L shell-dependent losses (that are consistent with whistler hiss interactions) return the belts to more quiescent conditions.

  6. Internal electron conversion of the isomeric {sup 57}Fe nucleus state with an energy of 14.4 keV excited by the radiation of the plasma of a high-power femtosecond laser pulse

    SciTech Connect

    Golovin, G V; Savel'ev-Trofimov, Andrei B; Uryupina, D S; Volkov, Roman V

    2011-03-31

    We recorded the spectrum of delayed secondary electrons ejected from the target, which was coated with a layer of iron enriched with the {sup 57}Fe isotope to 98%, under its irradiation by fluxes of broadband X-ray radiation and fast electrons from the plasma produced by a femtosecond laser pulse at an intensity of 10{sup 17} W cm{sup -2}. Maxima were identified at energies of 5.6, 7.2, and 13.6 keV in the spectrum obtained for a delay of 90 - 120 ns. The two last-listed maxima owe their origin to the internal electron conversion of the isomeric level with an energy of 14.4 keV and a lifetime of 98 ns to the K and L shells of atomic iron, respectively; the first-named level arises from a cascade K - L{sub 2}L{sub 3} Auger process. Photoexcitaion by the X-ray plasma radiation is shown to be the principal channel of the isomeric level excitation. (interaction of laser radiation with matter)

  7. Nuclear Energy -- Knowledge Base for Advanced Modeling and Simulation (NE-KAMS) Code Verification and Validation Data Standards and Requirements: Fluid Dynamics Version 1.0

    SciTech Connect

    Greg Weirs; Hyung Lee

    2011-09-01

    V&V and UQ are the primary means to assess the accuracy and reliability of M&S and, hence, to establish confidence in M&S. Though other industries are establishing standards and requirements for the performance of V&V and UQ, at present, the nuclear industry has not established such standards or requirements. However, the nuclear industry is beginning to recognize that such standards are needed and that the resources needed to support V&V and UQ will be very significant. In fact, no single organization has sufficient resources or expertise required to organize, conduct and maintain a comprehensive V&V and UQ program. What is needed is a systematic and standardized approach to establish and provide V&V and UQ resources at a national or even international level, with a consortium of partners from government, academia and industry. Specifically, what is needed is a structured and cost-effective knowledge base that collects, evaluates and stores verification and validation data, and shows how it can be used to perform V&V and UQ, leveraging collaboration and sharing of resources to support existing engineering and licensing procedures as well as science-based V&V and UQ processes. The Nuclear Energy Knowledge base for Advanced Modeling and Simulation (NE-KAMS) is being developed at the Idaho National Laboratory in conjunction with Bettis Laboratory, Sandia National Laboratories, Argonne National Laboratory, Utah State University and others with the objective of establishing a comprehensive and web-accessible knowledge base to provide V&V and UQ resources for M&S for nuclear reactor design, analysis and licensing. The knowledge base will serve as an important resource for technical exchange and collaboration that will enable credible and reliable computational models and simulations for application to nuclear power. NE-KAMS will serve as a valuable resource for the nuclear industry, academia, the national laboratories, the U.S. Nuclear Regulatory Commission (NRC) and

  8. Characteristics of Protons Exiting from a Polyethylene Converter Irradiated by Neutrons with Energies between 1 keV and 10 MeV

    PubMed Central

    Nikezic, D.; Shahmohammadi Beni, Mehrdad; Krstic, D.; Yu, K. N.

    2016-01-01

    Monte Carlo method has been used to determine the efficiency for proton production and to study the energy and angular distributions of the generated protons. The ENDF library of cross sections is used to simulate the interactions between the neutrons and the atoms in a polyethylene (PE) layer, while the ranges of protons with different energies in PE are determined using the Stopping and Range of Ions in Matter (SRIM) computer code. The efficiency of proton production increases with the PE layer thickness. However the proton escaping from a certain polyethylene volume is highly dependent on the neutron energy and target thickness, except for a very thin PE layer. The energy and angular distributions of protons are also estimated in the present paper, showing that, for the range of energy and thickness considered, the proton flux escaping is dependent on the PE layer thickness, with the presence of an optimal thickness for a fixed primary neutron energy. PMID:27362656

  9. OSLD energy response performance and dose accuracy at 24 - 1250 keV: Comparison with TLD-100H and TLD-100

    SciTech Connect

    Kadir, A. B. A.; Priharti, W.; Samat, S. B.; Dolah, M. T.

    2013-11-27

    OSLD was evaluated in terms of energy response and accuracy of the measured dose in comparison with TLD-100H and TLD-100. The OSLD showed a better energy response performance for H{sub p}(10) whereas for H{sub p}(0.07), TLD-100H is superior than the others. The OSLD dose accuracy is comparable with the other two dosimeters since it fulfilled the requirement of the ICRP trumpet graph analysis.

  10. CCAIN, Version 1.0

    SciTech Connect

    Rickett, Christopher D.; Rasmussen, Craig E.; Sottile, Matthew J.

    2005-05-26

    CCAIN, Version 1.0 Date: 06/15/2005 This software is an instantiation of Common Component Architecture (CCA) framework written in C. The framework is used to compose (create, register, destroy) C, C++, and Fortran components into a running CCA application. Language bindings are provided for F90 and F03 to allow codes in these languages to interface with the framework.

  11. Mass attenuation coefficient of binderless, pre-treated and tannin-based Rhizophora spp. particleboards using 16.59 – 25.26 keV photon energy range

    SciTech Connect

    Mohd Yusof, Mohd Fahmi Hamid, Puteri Nor Khatijah Abdul; Tajuddin, Abdul Aziz; Bauk, Sabar; Hashim, Rokiah

    2015-04-29

    The Rhizophora spp. particleboards were fabricated using ≤ 104 µm particle size at three different fabrication methods; binderless, steam pre-treated and tannin-added. The mass attenuation coefficient of Rhizophora spp. particleboards were measured using x-ray fluorescent (XRF) photon from niobium, molybdenum, palladium, silver and tin metal plates that provided photon energy between 16.59 to 25.26 keV. The results were compared to theoretical values for water calculated using photon cross-section database (XCOM).The results showed that all Rhizophora spp. particleboards having mass attenuation coefficient close to calculated XCOM for water. Tannin-added Rizophora spp. particleboard was nearest to calculated XCOM for water with χ2 value of 13.008 followed by binderless Rizophora spp. (25.859) and pre-treated Rizophora spp. (91.941)

  12. Comparison of some lead and non-lead based glass systems, standard shielding concretes and commercial window glasses in terms of shielding parameters in the energy region of 1 keV-100 GeV: A comparative study

    NASA Astrophysics Data System (ADS)

    Kurudirek, Murat; Özdemir, Yüksel; Şimşek, Önder; Durak, Rıdvan

    2010-12-01

    The effective atomic numbers, Z eff of some glass systems with and without Pb have been calculated in the energy region of 1 keV-100 GeV including the K absorption edges of high Z elements present in the glass. Also, these glass systems have been compared with some standard shielding concretes and commercial window glasses in terms of mean free paths and total mass attenuation coefficients in the continuous energy range. Comparisons with experiments were also provided wherever possible for glasses. It has been observed that the glass systems without Pb have higher values of Z eff than that of Pb based glasses at some high energy regions even if they have lower mean atomic numbers than Pb based glasses. When compared with some standard shielding concretes and commercial window glasses, generally it has been shown that the given glass systems have superior properties than concretes and window glasses with respect to the radiation-shielding properties, thus confirming the availability of using these glasses as substitutes for some shielding concretes and commercial window glasses to improve radiation-shielding properties in the continuous energy region.

  13. Analysis of temperature-dependent neutron transmission and self-indication measurements on tantalum at 2-keV neutron energy

    NASA Technical Reports Server (NTRS)

    Semler, T. T.

    1973-01-01

    The method of pseudo-resonance cross sections is used to analyze published temperature-dependent neutron transmission and self-indication measurements on tantalum in the unresolved region. In the energy region analyzed, 1825.0 to 2017.0 eV, a direct application of the pseudo-resonance approach using a customary average strength function will not provide effective cross sections which fit the measured cross section behavior. Rather a local value of the strength function is required, and a set of resonances which model the measured behavior of the effective cross sections is derived. This derived set of resonance parameters adequately represents the observed resonance hehavior in this local energy region. Similar analyses for the measurements in other unresolved energy regions are necessary to obtain local resonance parameters for improved reactor calculations. This study suggests that Doppler coefficients calculated by sampling from grand average statistical distributions over the entire unresolved resonance region can be in error, since significant local variations in the statistical distributions are not taken into consideration.

  14. R-matrix analysis of {sup 235}U neutron transmission and cross sections in the energy range 0 to 2.25 keV

    SciTech Connect

    Leal, L.C.; Derrien, H.; Larson, N.M.; Wright, R.Q.

    1997-11-01

    This document describes a new R-matrix analysis of {sup 235}U cross section data in the energy range from 0 to 2,250 eV. The analysis was performed with the computer code SAMMY, that has recently been updated to permit, for the first time, inclusion of both differential and integral data within the analysis process. Fourteen differential data sets and six integral quantities were used in this evaluation: two measurements of fission plus capture, one of fission plus absorption, six of fission alone, two of transmission, and one of eta, plus standard values of thermal cross sections for fission, capture, and scattering, and of K1 and the Westcott g-factors for both fission and absorption. An excellent representation was obtained for the high-resolution transmission, fission, and capture cross-section data as well as for the integral quantities. The result is a single set of resonance parameters spanning the entire range up to 2,250 eV, a decided improvement over the present ENDF/VI evaluation, in which eleven discrete resonance parameter sets are required to cover that same energy range. This new evaluation is expected to greatly improve predictability of the criticality safety margins for nuclear systems in which {sup 235}U is present.

  15. Feasibility study for DEXA using synchrotron CT at 20-35 keV

    NASA Astrophysics Data System (ADS)

    Midgley, S. M.

    2013-02-01

    A nonlinear model for the x-ray linear attenuation coefficient μ is employed for dual energy x-ray analysis (DEXA). Nonlinear simultaneous equations formed by μ and energy dependent model parameters are solved for the electron density Ne and fourth compositional ratio R4 which has the same ‘units’ as the atomic number. Computed tomography data was acquired at 20-35 keV using bending magnet synchrotron radiation, a double crystal monochromator, a rotation stage and an area detector. Test objects contained liquid samples as mixtures of ethanol, water and salt solutions with known density and composition. Various noise sources are identified and give μ uncertainties of 1-2%. A fan beam geometry allowed the detection of forward scattered radiation with measured μ being 6% lower than expectations for a narrow beam. Energy dependent model parameters were obtained by solving linear simultaneous equations formed by μ and material parameters based upon Ne and R4. DEXA accuracy was studied as a function of photon energy and sample composition. Propagation of errors analysis identifies the importance of the fractional compositional cross-products whose difference at the two beam energies should exceed 0.1, requiring 10 keV or more separation. For a reasonable approximation for the adjustable model parameters, the mean difference between the DEXA solution and true values (ΔNe, ΔR4) are (1.0%, 0.5%) for soft tissue and (1.5%, 0.8%) for bone like samples.

  16. Observations of celestial X-ray sources above 20 keV with the high-energy scintillation spectrometer on board OSO 8

    NASA Technical Reports Server (NTRS)

    Crannell, C. J.; Dennis, B. R.; Dolan, J. H.; Frost, K. J.; Orwig, L. E.; Beall, J. H.; Maurer, G. S.

    1977-01-01

    High-energy X-ray spectra of the Crab Nebula, Cyg- XR-1, and Cen A were determined from observations with the scintillation spectrometer on board the OSO-8 satellite, launched in June, 1975. Each of these sources was observed over two periods of 8 days or more, enabling a search for day-to-day and year to year variations in the spectral and temporal characteristics of the X-ray emission. No variation in the light curve of the Crab pulsar was found from observations which span a 15-day period in March 1976, with demonstrable phase stability. Transitions associated with the binary phase of Cyg XR-1 and a large change in the emission from Con A are reported.

  17. On the existence of low-energy photons (<150 keV) in the unflattened x-ray beam from an ordinary radiotherapeutic target in a medical linear accelerator.

    PubMed

    Tsechanski, A; Krutman, Y; Faermann, S

    2005-12-07

    Low-energy photons (<150 keV) are essential for obtaining high quality x-ray radiographs. These photons are usually produced in the accelerator target, but are effectively absorbed by the flattening filter and, at least partially, by the target itself. Experimental proof is presented for the existence of low-energy photons in the unflattened x-ray beam produced by a 6 MeV electron beam normally incident on the thinner of the two existing ports of the all-Cu radiotherapeutic target of a Clinac 18 (Varian Associates) linear accelerator. A number of one-shot absorption measurements were carried out with 12 foils of Pb absorbers with thicknesses varying from 0.25 to 3 mm in steps of 0.25 mm arranged symmetrically around the central axis on a 7.2 cm radius circumference. A Kodak ECL film-screen-cassette combination was used as a detector in the absorption measurements, in which optical density was measured as a function of the thickness of the Pb absorbers. Two sets of absorption measurements were carried out: the first one with the Clinac 18 6 MV unflattened beam and the second one with the Clinac 600C 6 MV therapeutic counterpart beam. There is a striking difference between the two sets: the optical density versus Pb-absorber thickness curve shows a sharp increase in optical density at small absorber thicknesses in the case of the unflattened 6 MV x-ray beam as compared with a gently sloping dependence in the case of the 6 MV therapeutic beam. A semi-quantitative assessment of the low-energy photon contribution to the whole optical density/contrast is presented. A 0.85 mm thick Pb absorber intercepting the 6 MV unflattened x-ray beam eliminates almost totally the sharp peak in the optical density curve at small Pb-absorber thicknesses. This constitutes additional evidence for the existence of low-energy photons (<150 keV) in the unflattened 6 MV beam from the Cu therapeutic target.

  18. Systematic survey of the dose enhancement in tissue-equivalent materials facing medium- and high-Z backscatterers exposed to X-rays with energies from 5 to 250 keV.

    PubMed

    Seidenbusch, M; Harder, D; Regulla, D

    2014-05-01

    The present study has been inspired by the results of earlier dose measurements in tissue-equivalent materials adjacent to thin foils of aluminum, copper, tin, gold, and lead. Large dose enhancements have been observed in low-Z materials near the interface when this ensemble was irradiated with X-rays of qualities known from diagnostic radiology. The excess doses have been attributed to photo-, Compton, and Auger electrons released from the metal surfaces. Correspondingly, high enhancements of biological effects have been observed in single cell layers arranged close to gold surfaces. The objective of the present work is to systematically survey, by calculation, the values of the dose enhancement in low-Z media facing backscattering materials with a variety of atomic numbers and over a large range of photon energies. Further parameters to be varied are the distance of the point of interest from the interface and the kind of the low-Z material. The voluminous calculations have been performed using the PHOTCOEF algorithm, a proven set of interpolation functions fitted to long-established Monte Carlo results, for primary photon energies between 5 and 250 keV and for atomic numbers varying over the periodic system up to Z = 100. The calculated results correlate well with our previous experimental results. It is shown that the values of the dose enhancement (a) vary strongly in dependence upon Z and photon energy; (b) have maxima in the energy region from 40 to 60 keV, determined by the K and L edges of the backscattering materials; and (c) are valued up to about 130 for "International Commission on Radiological Protection (ICRP) soft tissue" (soft tissue composition recommended by the ICRP) as the adjacent low-Z material. Maximum dose enhancement associated with the L edge occurs for materials with atomic numbers between 50 and 60, e.g., barium (Z = 56) and iodine (Z = 53). Such materials typically serve as contrast media in medical X-ray diagnostics. The gradual

  19. Measurement of the 13C(α, n)16O reaction at astrophysical energies using the Trojan Horse Method. Focus on the -3 keV sub-threshold resonance

    NASA Astrophysics Data System (ADS)

    La Cognata, M.; Spitaleri, C.; Trippella, O.; Kiss, G. G.; Rogachev, G. V.; Mukhamedzhanov, A. M.; Avila, M.; Guardo, G. L.; Koshchiy, E.; Kuchera, A.; Lamia, L.; Puglia, S. M. R.; Romano, S.; Santiago, D.; Spartà, R.

    2014-03-01

    Most of the nuclei in the mass range 90 ≲ A ≲ 208 are produced through the so-called s-process, namely through a series of neutron capture reactions on seed nuclei followed by β-decays. The 13C(α, n)16O reaction is the neutron source for the main component of the s-process. It is active inside the helium-burning shell of asymptotic giant branch stars, at temperatures ≲ 108 K, corresponding to an energy interval of 140 - 230 keV. In this region, the astrophysical S(E)-factor is dominated by the -3 keV sub-threshold resonance due to the 6.356 MeV level in 17O. Direct measurements could not soundly establish its contribution owing to the cross section suppression at astrophysical energies determined by the Coulomb barrier between interacting nuclei. Indirect measurements and extrapolations yielded inconsistent results, calling for further investigations. The Trojan Horse Method turns out to be very suited for the study of the 13C(α, n)16O reaction as it allows us to access the low as well as the negative energy re- gion, in particular in the case of resonance reactions. We have applied the Trojan HorseMethod to the 13C(6Li, n16O)d quasi-free reaction. By using the modified R-matrix approach, the asymptotic normalization coefficient {( {tilde C{α 13{{C}}}17{{O(1/}{{{2}}{ + }}{{)}}}} )^2} of the 6.356 MeV level has been deduced as well as the n-partial width, allowing to attain an unprecedented accuracy for the 13C(α, n)16O astrophysical factor. A preliminary analysis of a partial data set has lead to {( {tilde C{α 13{{C}}}17{{O(1/}{{{2}}{ + }}{{)}}}} )^2} = 6.7 - 0.6 + 0.9 {{f}}{{{m}} - 1}, slightly larger than the values in the literature, determining a 13C(α, n)16O reaction rate in agreement with the most results in the literature at ˜ 108 K, with enhanced accuracy thanks to this innovative approach.

  20. Development of ultralow energy (1-10 eV) ion scattering spectrometry coupled with reflection absorption infrared spectroscopy and temperature programmed desorption for the investigation of molecular solids.

    PubMed

    Bag, Soumabha; Bhuin, Radha Gobinda; Methikkalam, Rabin Rajan J; Pradeep, T; Kephart, Luke; Walker, Jeff; Kuchta, Kevin; Martin, Dave; Wei, Jian

    2014-01-01

    Extremely surface specific information, limited to the first atomic layer of molecular surfaces, is essential to understand the chemistry and physics in upper atmospheric and interstellar environments. Ultra low energy ion scattering in the 1-10 eV window with mass selected ions can reveal extremely surface specific information which when coupled with reflection absorption infrared (RAIR) and temperature programmed desorption (TPD) spectroscopies, diverse chemical and physical properties of molecular species at surfaces could be derived. These experiments have to be performed at cryogenic temperatures and at ultra high vacuum conditions without the possibility of collisions of neutrals and background deposition in view of the poor ion intensities and consequent need for longer exposure times. Here we combine a highly optimized low energy ion optical system designed for such studies coupled with RAIR and TPD and its initial characterization. Despite the ultralow collision energies and long ion path lengths employed, the ion intensities at 1 eV have been significant to collect a scattered ion spectrum of 1000 counts/s for mass selected CH2(+).

  1. High-contrast process using a positive-tone resist with antistatic coating and high-energy (100-keV) e-beam lithography for fabricating diffractive optical elements (DOE) on quartz

    NASA Astrophysics Data System (ADS)

    Poli, Louis C.; Kondek, Christine A.; Shoop, Barry L.; McLane, George F.

    1995-06-01

    Diffractive optical elements (DOE) are becoming important as optical signal processing elements in increasingly diverse applications. These elements, fabricated on quartz, may be used as phase shift type masks or as embedded components that implement a transfer function within a processing network. A process is under development for the fabrication of a DOE implementing a Jervis error diffusion kernel for research in half tone image processing. Dry etching is performed after lithography and pattern transfer through a nickel mask. This results in etched areal features on the substrate. An optical diffraction medium is thus created. Lithographic patterning is done by e-beam lithography (EBL) to realize small features, but also offers the important advantage of a large depth of field which relaxes the problem of complex surface topology. The recent availability of high energy (100 KeV) lithography tools provides a capability for precision overlay, small feature resolution, and enhanced image contrast through a lower induced proximity effect. Patterning by EBL on insulating substrates is complicated by the necessity of providing a vehicle for the avoidance of charge buildup on the surface. In a previously presented paper a methodology was shown for the use of TQV-501 (Nitto Chemical) antistatic compound as a final spin on film for use with PMMA and SAL-601 (Shipley). In this current work, a process is described using EBL and a high performance positive resist working with a final film layer of antistatic TQV-501 on a nickel coated wafer. The process may then be reapplied to realize additional lithographic levels in registration, for multilevel DOE components. High energy (100 KeV) EBL is used to provide high quality pattern definition. The e-beam sensitive resist, ZEP-320-37 (Nagase Chemical) in dilution, together with a top film layer of TQV-501 serves as a bilevel resist system and is used for patterning the desired image before definition of the nickel mask through

  2. Observation of atomic oxygen O(1S) green-line emission in the summer polar upper mesosphere associated with high-energy (≥30 keV) electron precipitation during high-speed solar wind streams

    NASA Astrophysics Data System (ADS)

    Lee, Young-Sook; Kwak, Young-Sil; Kim, Kyung-Chan; Solheim, Brian; Lee, Regina; Lee, Jaejin

    2017-01-01

    The auroral green-line emission at 557.7 nm wavelength as arising from the atomic oxygen O(1S → 1D) transition typically peaks at an altitude of 100 km specifically in the nightside oval, induced by auroral electrons within an energy range of 100 eV-30 keV. Intense aurora is known as being suppressed by sunlight in summer daytime but usually occurs in low electrical background conductivity. However, in the present study in summer (July) sunlit condition, enhancements of O(1S) emission rates observed by using the Wind Imaging Interferometer/UARS were frequently observed at low altitudes below 90 km, where ice particles are created initially as subvisible and detected as polar mesosphere summer echoes, emerging to be an optical phenomenon of polar mesospheric clouds. The intense O(1S) emission occurring in summer exceeds those occurring in the daytime in other seasons both in occurrence and in intensity, frequently accompanied by occurrences of supersonic neutral velocity (300-1500 m s-1). In the mesosphere, ion motion is controlled by electric field and the momentum is transferred to neutrals. The intense O(1S) emission is well associated with high-energy electron precipitation as observed during an event of high-speed solar wind streams. Meanwhile, since the minimum occurrences of O(1S) emission and supersonic velocity are maintained even in the low precipitation flux, the mechanism responsible is not only related to high-energy electron precipitation but also presumably to the local conditions, including the composition of meteoric-charged ice particles and charge separation expected in extremely low temperatures (<150 K).

  3. Measurement of the x-ray mass attenuation coefficient and determination of the imaginary component of the atomic form factor of tin over the energy range of 29-60keV

    NASA Astrophysics Data System (ADS)

    de Jonge, Martin D.; Tran, Chanh Q.; Chantler, Christopher T.; Barnea, Zwi; Dhal, Bipin B.; Paterson, David; Kanter, Elliot P.; Southworth, Stephen H.; Young, Linda; Beno, Mark A.; Linton, Jennifer A.; Jennings, Guy

    2007-03-01

    We use the x-ray extended-range technique (XERT) [C. T. Chantler , Phys. Rev. A 64, 062506 (2001)] to measure the mass attenuation coefficients of tin in the x-ray energy range of 29-60keV to 0.04-3% accuracy, and typically in the range 0.1-0.2% . Measurements made over an extended range of the measurement parameter space are critically examined to identify, quantify, and correct a number of potential experimental systematic errors. These results represent the most extensive experimental data set for tin and include absolute mass attenuation coefficients in the regions of x-ray absorption fine structure, extended x-ray absorption fine structure, and x-ray absorption near-edge structure. The imaginary component of the atomic form factor f2 is derived from the photoelectric absorption after subtracting calculated Rayleigh and Compton scattering cross sections from the total attenuation. Comparison of the result with tabulations of calculated photoelectric absorption coefficients indicates that differences of 1-2% persist between calculated and observed values.

  4. The response of a fast scintillator screen (YAP:Ce) to low energy ions (0-40 keV) and its use to detect fast-ion-loss in stellarator TJ-II.

    PubMed

    Martínez, M; Zurro, B; Baciero, A; Jiménez-Rey, D; Tribaldos, V; Malo, M; Crespo, M T; Muñoz, D

    2016-11-01

    A systematic study of scintillation materials was undertaken to improve the time resolution of the fast ion diagnostic currently installed at TJ-II stellarator. It was found that YAP:Ce (formula YAlO3:Ce, Yttrium Aluminum Perovskite doped with Cerium) ionoluminescence offers better sensitivity and time response compared to the standard detector material, SrGa2S4:Eu (TG-Green), currently used in TJ-II. A comparison between both materials was carried out by irradiating them with H(+) ions of up to 40 keV using a dedicated laboratory setup. It is found that for the low energy ions of interest at TJ-II, YAP:Ce offers 20 times higher sensitivity than TG-Green and much faster decay time, 27 ns versus 540 ns. It is expected that the use of YAP:Ce in combination with a faster data acquisition and an ion counting software as part of the TJ-II ion luminescent probe will provide 20 times faster data on ion loss.

  5. Neutron scattering measurements in {sup 197}Au from 850 keV to 2.0 MeV

    SciTech Connect

    O`Connor, M.; Chen, J.; Egan, J.J.

    1995-10-01

    Differential elastic and inelastic neutron scattering cross-sections for low lying levels in {sup 197}Au have been measured for incident neutron energies of 1.0 MeV, 1.5 MeV and 2.0 MeV. In addition, the total neutron cross sections in {sup 197}Au was measured from 850 keV to 1.5 MeV. For both experiments the UML 5.5 MV Van-de-Graaff accelerator with a Mobley post acceleration compression system, produced subnanosecond proton pulses which generated neutrons via the {sup 7}Li(p,n) {sup 7}Be reaction.

  6. Fermi Observations of GRB 090510: A Short-Hard Gamma-ray Burst with an Additional, Hard Power-law Component from 10 keV TO GeV Energies

    NASA Astrophysics Data System (ADS)

    Ackermann, M.; Asano, K.; Atwood, W. B.; Axelsson, M.; Baldini, L.; Ballet, J.; Barbiellini, G.; Baring, M. G.; Bastieri, D.; Bechtol, K.; Bellazzini, R.; Berenji, B.; Bhat, P. N.; Bissaldi, E.; Blandford, R. D.; Bloom, E. D.; Bonamente, E.; Borgland, A. W.; Bouvier, A.; Bregeon, J.; Brez, A.; Briggs, M. S.; Brigida, M.; Bruel, P.; Buson, S.; Caliandro, G. A.; Cameron, R. A.; Caraveo, P. A.; Carrigan, S.; Casandjian, J. M.; Cecchi, C.; Çelik, Ö.; Charles, E.; Chiang, J.; Ciprini, S.; Claus, R.; Cohen-Tanugi, J.; Connaughton, V.; Conrad, J.; Dermer, C. D.; de Palma, F.; Dingus, B. L.; Silva, E. do Couto e.; Drell, P. S.; Dubois, R.; Dumora, D.; Farnier, C.; Favuzzi, C.; Fegan, S. J.; Finke, J.; Focke, W. B.; Frailis, M.; Fukazawa, Y.; Fusco, P.; Gargano, F.; Gasparrini, D.; Gehrels, N.; Germani, S.; Giglietto, N.; Giordano, F.; Glanzman, T.; Godfrey, G.; Granot, J.; Grenier, I. A.; Grondin, M.-H.; Grove, J. E.; Guiriec, S.; Hadasch, D.; Harding, A. K.; Hays, E.; Horan, D.; Hughes, R. E.; Jóhannesson, G.; Johnson, W. N.; Kamae, T.; Katagiri, H.; Kataoka, J.; Kawai, N.; Kippen, R. M.; Knödlseder, J.; Kocevski, D.; Kouveliotou, C.; Kuss, M.; Lande, J.; Latronico, L.; Lemoine-Goumard, M.; Llena Garde, M.; Longo, F.; Loparco, F.; Lott, B.; Lovellette, M. N.; Lubrano, P.; Makeev, A.; Mazziotta, M. N.; McEnery, J. E.; McGlynn, S.; Meegan, C.; Mészáros, P.; Michelson, P. F.; Mitthumsiri, W.; Mizuno, T.; Moiseev, A. A.; Monte, C.; Monzani, M. E.; Moretti, E.; Morselli, A.; Moskalenko, I. V.; Murgia, S.; Nakajima, H.; Nakamori, T.; Nolan, P. L.; Norris, J. P.; Nuss, E.; Ohno, M.; Ohsugi, T.; Omodei, N.; Orlando, E.; Ormes, J. F.; Ozaki, M.; Paciesas, W. S.; Paneque, D.; Panetta, J. H.; Parent, D.; Pelassa, V.; Pepe, M.; Pesce-Rollins, M.; Piron, F.; Preece, R.; Rainò, S.; Rando, R.; Razzano, M.; Razzaque, S.; Reimer, A.; Ritz, S.; Rodriguez, A. Y.; Roth, M.; Ryde, F.; Sadrozinski, H. F.-W.; Sander, A.; Scargle, J. D.; Schalk, T. L.; Sgrò, C.; Siskind, E. J.; Smith, P. D.; Spandre, G.; Spinelli, P.; Stamatikos, M.; Stecker, F. W.; Strickman, M. S.; Suson, D. J.; Tajima, H.; Takahashi, H.; Takahashi, T.; Tanaka, T.; Thayer, J. B.; Thayer, J. G.; Thompson, D. J.; Tibaldo, L.; Toma, K.; Torres, D. F.; Tosti, G.; Tramacere, A.; Uchiyama, Y.; Uehara, T.; Usher, T. L.; van der Horst, A. J.; Vasileiou, V.; Vilchez, N.; Vitale, V.; von Kienlin, A.; Waite, A. P.; Wang, P.; Wilson-Hodge, C.; Winer, B. L.; Wu, X. F.; Yamazaki, R.; Yang, Z.; Ylinen, T.; Ziegler, M.

    2010-06-01

    We present detailed observations of the bright short-hard gamma-ray burst GRB 090510 made with the Gamma-ray Burst Monitor (GBM) and Large Area Telescope (LAT) on board the Fermi observatory. GRB 090510 is the first burst detected by the LAT that shows strong evidence for a deviation from a Band spectral fitting function during the prompt emission phase. The time-integrated spectrum is fit by the sum of a Band function with E peak = 3.9 ± 0.3 MeV, which is the highest yet measured, and a hard power-law component with photon index -1.62 ± 0.03 that dominates the emission below ≈20 keV and above ≈100 MeV. The onset of the high-energy spectral component appears to be delayed by ~0.1 s with respect to the onset of a component well fit with a single Band function. A faint GBM pulse and a LAT photon are detected 0.5 s before the main pulse. During the prompt phase, the LAT detected a photon with energy 30.5+5.8 -2.6 GeV, the highest ever measured from a short GRB. Observation of this photon sets a minimum bulk outflow Lorentz factor, Γgsim 1200, using simple γγ opacity arguments for this GRB at redshift z = 0.903 and a variability timescale on the order of tens of ms for the ≈100 keV-few MeV flux. Stricter high confidence estimates imply Γ >~ 1000 and still require that the outflows powering short GRBs are at least as highly relativistic as those of long-duration GRBs. Implications of the temporal behavior and power-law shape of the additional component on synchrotron/synchrotron self-Compton, external-shock synchrotron, and hadronic models are considered.

  7. Seeded quantum FEL at 478 keV

    SciTech Connect

    Guenther, M. M.; Jentschel, M.; Thirolf, P. G.; Seggebrock, T.; Habs, D.

    2012-07-09

    We present for the first time the concept of a seeded {gamma} quantum Free-Electron-Laser (QFEL) at 478 keV, which has very different properties compared to a classical. The basic concept is to produce a highly brilliant {gamma} beam via SASE. To produce highly intense and coherent {gamma} beam, we intend to use a seeded FEL scheme. Important for the production of such a {gamma} beam are novel refractive {gamma}-lenses for focusing and an efficient monochromator, allowing to generate a very intense and coherent seed beam. The energy of the {gamma} beam is 478 keV, corresponding to a wavelength in the sub-Angstrom regime (1/38 A). To realize a coherent {gamma} beam at 478 keV, it is necessary to use a quantum FEL design. At such high radiation energies a classical description of the {gamma}-FEL becomes wrong.

  8. Characterization of AGIPD1.0: The full scale chip

    NASA Astrophysics Data System (ADS)

    Mezza, D.; Allahgholi, A.; Arino-Estrada, G.; Bianco, L.; Delfs, A.; Dinapoli, R.; Goettlicher, P.; Graafsma, H.; Greiffenberg, D.; Hirsemann, H.; Jack, S.; Klanner, R.; Klyuev, A.; Krueger, H.; Marras, A.; Mozzanica, A.; Poehlsen, J.; Schmitt, B.; Schwandt, J.; Sheviakov, I.; Shi, X.; Trunk, U.; Xia, Q.; Zhang, J.; Zimmer, M.

    2016-12-01

    The AGIPD (adaptive gain integrating pixel detector) detector is a high frame rate (4.5 MHz) and high dynamic range (up to 104 ·12.4 keV photons) detector with single photon resolution (down to 4 keV taking 5σ as limit and lowest noise settings) developed for the European XFEL (XFEL.EU). This work is focused on the characterization of AGIPD1.0, which is the first full scale version of the chip. The chip is 64×64 pixels and each pixel has a size of 200×200 μm2. Each pixel can store up to 352 images at a rate of 4.5 MHz (corresponding to 220 ns). A detailed characterization of the AGIPD1.0 chip has been performed in order to assess the main performance of the ASIC in terms of gain, noise, speed and dynamic range. From the measurements presented in this paper a good uniformity of the gain, a noise around 320 e- (rms) in standard mode and around 240 e- (rms) in high gain mode has been measured. Furthermore a detailed discussion about the non-linear behavior after the gain switching is presented with both experimental results and simulations.

  9. Irradiation effects on secondary structure of protein induced by keV ions

    NASA Astrophysics Data System (ADS)

    Cui, F. Z.; Lin, Y. B.; Zhang, D. M.; Tian, M. B.

    2001-01-01

    Protein secondary structure changes by low-energy ion irradiation are reported for the first time. The selected system is 30 keV N + irradiation on bovine serum albumin (BSA). After irradiation at increasing fluences from 1.0×10 15 to 2.5×10 16 ion/cm 2, Fourier transform infrared spectra analysis was conducted. It was found that the secondary structures of BSA molecules were very sensitive to ion irradiation. Secondary conformations showed different trends of change during irradiation. With the increase of ion fluence from 0 to 2.5×10 16 ion/cm 2, the fraction of α-helix and β-turns decreased from 17 to 12%, and from 40 to 31%, respectively, while that of random coil and β-sheet structure increased from 18 to 27%, and from 25 to 30%, respectively. Possible explanations for the secondary conformational changes of protein are proposed.

  10. Linear attenuation coefficients of tissues from 1 keV to 150 keV

    NASA Astrophysics Data System (ADS)

    Böke, Aysun

    2014-09-01

    The linear attenuation coefficients and three interaction processes have been computed for liver, kidney, muscle, fat and for a range of x-ray energies from 1 keV to 150 keV. Molecular photoelectric absorption cross sections were calculated from atomic cross section data. Total coherent (Rayleigh) and incoherent (Compton) scattering cross sections were obtained by numerical integration over combinations of F2m(x) with the Thomson formula and Sm(x) with the Klein-Nishina formula, respectively. For the coherent (Rayleigh) scattering cross section calculations, molecular form factors were obtained from recent experimental data in the literature for values of x<1 Å-1 and from the relativistic modified atomic form factors for values of x≥1 Å-1. With the inclusion of molecular interference effects in the coherent (Rayleigh) scattering, more accurate knowledge of the scatter from these tissues will be provided. The number of elements involved in tissue composition is 5 for liver, 47 for kidney, 44 for muscle and 3 for fat. The results are compared with previously published experimental and theoretical linear attenuation coefficients. In general, good agreement is obtained. The molecular form factors and scattering functions and cross sections are incorporated into a Monte Carlo program. The energy distributions of x-ray photons scattered from tissues have been simulated and the results are presented.

  11. 7 CFR 1.10 - Search services.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 1 2011-01-01 2011-01-01 false Search services. 1.10 Section 1.10 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.10 Search services. Search services are services of agency personnel—clerical or professional—used in trying to find...

  12. 7 CFR 1.10 - Search services.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 1 2013-01-01 2013-01-01 false Search services. 1.10 Section 1.10 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.10 Search services. Search services are services of agency personnel—clerical or professional—used in trying to find...

  13. 7 CFR 1.10 - Search services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Search services. 1.10 Section 1.10 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.10 Search services. Search services are services of agency personnel—clerical or professional—used in trying to find...

  14. Comparison between an event-by-event Monte Carlo code, NOREC, and ETRAN for electron scaled point kernels between 20 keV and 1 MeV.

    PubMed

    Cho, Sang Hyun; Vassiliev, Oleg N; Horton, John L

    2007-03-01

    An event-by-event Monte Carlo code called NOREC, a substantially improved version of the Oak Ridge electron transport code (OREC), was released in 2003, after a number of modifications to OREC. In spite of some earlier work, the characteristics of the code have not been clearly shown so far, especially for a wide range of electron energies. Therefore, NOREC was used in this study to generate one of the popular dosimetric quantities, the scaled point kernel, for a number of electron energies between 0.02 and 1.0 MeV. Calculated kernels were compared with the most well-known published kernels based on a condensed history Monte Carlo code, ETRAN, to show not only general agreement between the codes for the electron energy range considered but also possible differences between an event-by-event code and a condensed history code. There was general agreement between the kernels within about 5% up to 0.7 r/r (0) for 100 keV and 1 MeV electrons. Note that r/r (0) denotes the scaled distance, where r is the radial distance from the source to the dose point and r (0) is the continuous slowing down approximation (CSDA) range of a mono-energetic electron. For the same range of scaled distances, the discrepancies for 20 and 500 keV electrons were up to 6 and 12%, respectively. Especially, there was more pronounced disagreement for 500 keV electrons than for 20 keV electrons. The degree of disagreement for 500 keV electrons decreased when NOREC results were compared with published EGS4/PRESTA results, producing similar agreement to other electron energies.

  15. MaRIE 1.0: The Matter-Radiation Interactions in Extremes Project, and the Challenge of Dynamic Mesoscale Imaging

    SciTech Connect

    Barnes, Cris William; Barber, John L.; Kober, Edward Martin; Lookman, Turab; Sandberg, Richard L.; Shlachter, Jack S.; Sheffield, Richard L.

    2015-02-23

    The Matter-Radiation Interactions in Extremes project will build the experimental facility for the time-dependent control of dynamic material performance. An x-ray free electron laser at up to 42-keV fundamental energy and with photon pulses down to sub-nanosecond spacing, MaRIE 1.0 is designed to meet the challenges of time-dependent mesoscale materials science. Those challenges will be outlined, the techniques of coherent diffractive imaging and dynamic polycrystalline diffraction described, and the resulting requirements defined for a coherent x-ray source. The talk concludes with the role of the MaRIE project and science in the future.

  16. High angular resolution cosmic X-ray astronomy observations in the energy range 0.15-2 keV and XUV observations of nearby stars from an attitude controlled rocket

    NASA Technical Reports Server (NTRS)

    Garmire, G. P.

    1974-01-01

    The construction of a two dimensional focusing Wolter Type I mirror system for X-ray and XUV astronomical observations from an Astrobee F sounding rocket is described. The mirror design goal will have a one degree field, a 20-arc seconds resolution, an effective area of about 50 sq cm at 1 keV and 10 sq cm at 0.25 keV on axis. A star camera provides aspect data to about 15-arc seconds. Two detectors are placed at the focus with an interchange mechanism to allow a detector change during flight. The following specific developments are reported: (1) position sensitive proportional counter development; (2) channel plate multiplier development; (3) telescope mirror development and payload structure; (4) Australian rocket flight results; (5) Comet Kohoutek He I observation; and (6) Vela, Puppis A, and Gem-Mon bright patch observations.

  17. Radiation hardness assessment of the charge-integrating hybrid pixel detector JUNGFRAU 1.0 for photon science

    SciTech Connect

    Jungmann-Smith, J. H. Bergamaschi, A.; Brückner, M.; Dinapoli, R.; Greiffenberg, D.; Jaggi, A.; Maliakal, D.; Mayilyan, D.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Ruder, Ch.; Schädler, L.; Schmitt, B.; Shi, X.; Tinti, G.; Cartier, S.; Medjoubi, K.

    2015-12-15

    JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications in free electron lasers, particularly SwissFEL, and synchrotron light sources. JUNGFRAU is an automatic gain switching, charge-integrating detector which covers a dynamic range of more than 10{sup 4} photons of an energy of 12 keV with a good linearity, uniformity of response, and spatial resolving power. The JUNGFRAU 1.0 application-specific integrated circuit (ASIC) features a 256 × 256 pixel matrix of 75 × 75 μm{sup 2} pixels and is bump-bonded to a 320 μm thick Si sensor. Modules of 2 × 4 chips cover an area of about 4 × 8 cm{sup 2}. Readout rates in excess of 2 kHz enable linear count rate capabilities of 20 MHz (at 12 keV) and 50 MHz (at 5 keV). The tolerance of JUNGFRAU to radiation is a key issue to guarantee several years of operation at free electron lasers and synchrotrons. The radiation hardness of JUNGFRAU 1.0 is tested with synchrotron radiation up to 10 MGy of delivered dose. The effect of radiation-induced changes on the noise, baseline, gain, and gain switching is evaluated post-irradiation for both the ASIC and the hybridized assembly. The bare JUNGFRAU 1.0 chip can withstand doses as high as 10 MGy with minor changes to its noise and a reduction in the preamplifier gain. The hybridized assembly, in particular the sensor, is affected by the photon irradiation which mainly shows as an increase in the leakage current. Self-healing of the system is investigated during a period of 11 weeks after the delivery of the radiation dose. Annealing radiation-induced changes by bake-out at 100 °C is investigated. It is concluded that the JUNGFRAU 1.0 pixel is sufficiently radiation-hard for its envisioned applications at SwissFEL and synchrotron beam lines.

  18. Radiation hardness assessment of the charge-integrating hybrid pixel detector JUNGFRAU 1.0 for photon science

    NASA Astrophysics Data System (ADS)

    Jungmann-Smith, J. H.; Bergamaschi, A.; Brückner, M.; Cartier, S.; Dinapoli, R.; Greiffenberg, D.; Jaggi, A.; Maliakal, D.; Mayilyan, D.; Medjoubi, K.; Mezza, D.; Mozzanica, A.; Ramilli, M.; Ruder, Ch.; Schädler, L.; Schmitt, B.; Shi, X.; Tinti, G.

    2015-12-01

    JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications in free electron lasers, particularly SwissFEL, and synchrotron light sources. JUNGFRAU is an automatic gain switching, charge-integrating detector which covers a dynamic range of more than 104 photons of an energy of 12 keV with a good linearity, uniformity of response, and spatial resolving power. The JUNGFRAU 1.0 application-specific integrated circuit (ASIC) features a 256 × 256 pixel matrix of 75 × 75 μm2 pixels and is bump-bonded to a 320 μm thick Si sensor. Modules of 2 × 4 chips cover an area of about 4 × 8 cm2. Readout rates in excess of 2 kHz enable linear count rate capabilities of 20 MHz (at 12 keV) and 50 MHz (at 5 keV). The tolerance of JUNGFRAU to radiation is a key issue to guarantee several years of operation at free electron lasers and synchrotrons. The radiation hardness of JUNGFRAU 1.0 is tested with synchrotron radiation up to 10 MGy of delivered dose. The effect of radiation-induced changes on the noise, baseline, gain, and gain switching is evaluated post-irradiation for both the ASIC and the hybridized assembly. The bare JUNGFRAU 1.0 chip can withstand doses as high as 10 MGy with minor changes to its noise and a reduction in the preamplifier gain. The hybridized assembly, in particular the sensor, is affected by the photon irradiation which mainly shows as an increase in the leakage current. Self-healing of the system is investigated during a period of 11 weeks after the delivery of the radiation dose. Annealing radiation-induced changes by bake-out at 100 °C is investigated. It is concluded that the JUNGFRAU 1.0 pixel is sufficiently radiation-hard for its envisioned applications at SwissFEL and synchrotron beam lines.

  19. Radiation hardness assessment of the charge-integrating hybrid pixel detector JUNGFRAU 1.0 for photon science.

    PubMed

    Jungmann-Smith, J H; Bergamaschi, A; Brückner, M; Cartier, S; Dinapoli, R; Greiffenberg, D; Jaggi, A; Maliakal, D; Mayilyan, D; Medjoubi, K; Mezza, D; Mozzanica, A; Ramilli, M; Ruder, Ch; Schädler, L; Schmitt, B; Shi, X; Tinti, G

    2015-12-01

    JUNGFRAU (adJUstiNg Gain detector FoR the Aramis User station) is a two-dimensional hybrid pixel detector for photon science applications in free electron lasers, particularly SwissFEL, and synchrotron light sources. JUNGFRAU is an automatic gain switching, charge-integrating detector which covers a dynamic range of more than 10(4) photons of an energy of 12 keV with a good linearity, uniformity of response, and spatial resolving power. The JUNGFRAU 1.0 application-specific integrated circuit (ASIC) features a 256 × 256 pixel matrix of 75 × 75 μm(2) pixels and is bump-bonded to a 320 μm thick Si sensor. Modules of 2 × 4 chips cover an area of about 4 × 8 cm(2). Readout rates in excess of 2 kHz enable linear count rate capabilities of 20 MHz (at 12 keV) and 50 MHz (at 5 keV). The tolerance of JUNGFRAU to radiation is a key issue to guarantee several years of operation at free electron lasers and synchrotrons. The radiation hardness of JUNGFRAU 1.0 is tested with synchrotron radiation up to 10 MGy of delivered dose. The effect of radiation-induced changes on the noise, baseline, gain, and gain switching is evaluated post-irradiation for both the ASIC and the hybridized assembly. The bare JUNGFRAU 1.0 chip can withstand doses as high as 10 MGy with minor changes to its noise and a reduction in the preamplifier gain. The hybridized assembly, in particular the sensor, is affected by the photon irradiation which mainly shows as an increase in the leakage current. Self-healing of the system is investigated during a period of 11 weeks after the delivery of the radiation dose. Annealing radiation-induced changes by bake-out at 100 °C is investigated. It is concluded that the JUNGFRAU 1.0 pixel is sufficiently radiation-hard for its envisioned applications at SwissFEL and synchrotron beam lines.

  20. 1,10-Phenanthrolinium ionic liquid crystals.

    PubMed

    Cardinaels, Thomas; Lava, Kathleen; Goossens, Karel; Eliseeva, Svetlana V; Binnemans, Koen

    2011-03-01

    The 1,10-phenanthrolinium cation is introduced as a new building block for the design of ionic liquid crystals. 1,10-Phenanthroline, 5-methyl-1,10-phenanthroline, 5-chloro-1,10-phenanthroline, and 4,7-diphenyl-1,10-phenanthroline were quaternized by reaction with 1,3-dibromopropane or 1,2-dibromoethane. The resulting cations were combined with dodecyl sulfate or dioctyl sulfosuccinate anions. The influence of both the cation and anion type on the thermal behavior was investigated. Several of the complexes exhibit mesomorphic behavior, with smectic E phases for the dodecyl sulfate salts and smectic A phases for the dioctyl sulfosuccinate salts. Structural models for the packing of the 1,10-phenanthrolinium and anionic moieties in the liquid-crystalline phases are presented. The ionic compounds show fluorescence in the solid state and in solution.

  1. Nighttime observations of 0.2- to 26-keV electrons in the South Atlantic anomaly made by Atmosphere Explorer C

    NASA Technical Reports Server (NTRS)

    Gledhill, J. A.; Hoffman, R. A.

    1981-01-01

    Atmosphere Explorer C satellite observations have determined that the flux of low energy ions in the South Atlantic Anomaly is much smaller than that of electrons, allowing the satellite's low-energy ion detector to monitor the high-energy background and correct the low-energy electron detector accordingly. It is shown that the electron spectra can be represented by a power law in the range 0.2-26.0 keV, with the spectral index close to -1.0, and that the mean energy flux carried by electrons in the middle of the anomaly is about 0.003 erg/sq cm/sec and may reach 5 times this value. Maps of the downward energy flux are included.

  2. BenMAP 1.0

    EPA Pesticide Factsheets

    BenMAP 1.0 is the legacy version of the BenMAP software that the EPA is making available for archival purposes. It is designed for regional and national-scale analyses within the Continental United States.

  3. Evaluation of the 232Th Neutron Cross Sections between 4 keV and 140 keV

    SciTech Connect

    Volev, K.; Koyumdjieva, N.; Brusegan, A.; Borella, A.; Siegler, P.; Schillebeeckx, P.; Janeva, N.; Lukyanov, A.; Leal, L.

    2005-05-24

    An evaluation of the 232Th neutron total and capture cross sections has been performed in the energy region between 4 keV and 140 keV. The evaluation results from a simultaneous analysis of capture, transmission, and self-indication measurement data, including the most recent capture cross-section data obtained at the GELINA facility of the Institute for Reference Materials and Measurements at Geel (B) and at the n-TOF facility at CERN (CH). The experimental data have been analysed in terms of average resonance parameters exploiting two independent theoretical approaches -- the Characteristic Function model and the Hauser-Feshbach-Moldauer theory. The resulting parameters are consistent with the resolved resonance parameters deduced from the transmission measurements of Olsen et al. at the ORELA facility.

  4. Insider Alert 1.0 Beta Version

    SciTech Connect

    Abbott, Robert

    2004-02-01

    Insider Alert 1.0 Beta Version supports interactive selection and graphical display of data generated by the Sandia Cognitive Framework, which simulates the examination of security data by experts of various specialties. Insider Alert also encompasses the configuration and data files input to the Cognitive Framework for this application. Insider Alert 1.0 Beta Version is a computer program for analyzing data indicative of possible espionage or improper handling of data by employees at Sandia National Laboratories (or other facilities with comparable policies and procedures for managing sensitive information) It prioritizes and displays information for review by security analysts.

  5. Analysis of photon emission from 50--350-keV proton impact on H2O

    NASA Astrophysics Data System (ADS)

    Goldman, Benjamin D.; Timpone, Stephanie A.; Monce, Michael N.; Mitchell, Laurel; Griffin, Brian

    2011-04-01

    We have measured photon emission cross sections from neutral fragments produced by collisions of 50-350 keV protons with H2O molecules. Balmer α-δ emissions from both the target and projectile were recorded. We also analyzed A2Σ+-X2Π (0,0) and (1,0) emission from the excited OH fragment produced during target dissociation. Trends in the cross sections revealed two key properties of the collision process: (1) The Bethe theory accurately describes target emission from both H and OH fragments and (2) the ratio of any two Balmer emission cross sections for both the target and projectile can be approximated by simple functions of the respective optical oscillator strengths. Finally, we provide the Bethe fit parameters necessary to calculate the target emission cross sections at all nonrelativistic impact energies.

  6. Anisotropy measurements of nearly 50 KeV solar protons

    NASA Technical Reports Server (NTRS)

    Gold, R. E.; Bostrom, C. O.; Roelof, E. C.; Williams, D. J.

    1975-01-01

    The Energetic Particles Experiment on IMP-7 measures the angular distribution of 50-200 keV solar protons in 16 sectors. The velocity of 50 keV protons may be less than 5 times that of the solar wind. A generalized nonlinear Compton-Getting point transformation into the co-moving frame that contains no assumptions as to the angular distribution of either the spectrum or intensity is presented. Nearly 50 keV proton data in the spacecraft frame exhibit an anisotropy ratio that is large (not less than 5) and radial throughout the October 29, 1972 event lasting more than 9 days at this energy. This anisotropy argues against impulsive injection and diffusive decay in the inner solar system. Application of the transformation to the data reveals a long lasting residual anisotropy in the co-moving frame with protons streaming from the sun. Differences between the co-moving frame and solar wind frame velocities suggest residual electric fields upstream from the bow shock.

  7. Optimal Path Analyzer (Version 1.0)

    DTIC Science & Technology

    1989-10-01

    ABSTRACT (Continue on reverse if necessary and identify by block number) This report describes the function, operation, test and evaluation results of the...14 Technical Description ........................................ 14 Test and Evaluation .......................................... 16...Neural Network .................................. 10 5. Output Iteration Test Results ........................... 19 6. OPA 1.0 Sample Run B3 - S3

  8. Calculation of electron-impact rotationally elastic total cross sections for NH{sub 3}, H{sub 2}S, and PH{sub 3} over the energy range from 0.01 eV to 2 keV

    SciTech Connect

    Limbachiya, Chetan; Vinodkumar, Minaxi; Mason, Nigel

    2011-04-15

    This paper report results of calculation of the total cross section Q{sub T} for electron impact on NH{sub 3}, H{sub 2}S, and PH{sub 3} over a wide range of incident energies from 0.01 eV to 2 keV. Total cross sections Q{sub T} (elastic plus electronic excitation) for incident energies below the ionization threshold of the target were calculated using the UK molecular R-matrix code through the Quantemol-N software package and cross sections at higher energies were derived using the spherical complex optical potential formalism. The two methods are found to give self-consistent values where they overlap. The present results are, in general, found to be in good agreement with previous experimental and theoretical results.

  9. X-ray spectroscopy for chemistry in the 2-4 keV energy regime at the XMaS beamline: ionic liquids, Rh and Pd catalysts in gas and liquid environments, and Cl contamination in γ-Al2O3.

    PubMed

    Thompson, Paul B J; Nguyen, Bao N; Nicholls, Rachel; Bourne, Richard A; Brazier, John B; Lovelock, Kevin R J; Brown, Simon D; Wermeille, Didier; Bikondoa, Oier; Lucas, Christopher A; Hase, Thomas P A; Newton, Mark A

    2015-11-01

    The 2-4 keV energy range provides a rich window into many facets of materials science and chemistry. Within this window, P, S, Cl, K and Ca K-edges may be found along with the L-edges of industrially important elements from Y through to Sn. Yet, compared with those that cater for energies above ca. 4-5 keV, there are relatively few resources available for X-ray spectroscopy below these energies. In addition, in situ or operando studies become to varying degrees more challenging than at higher X-ray energies due to restrictions imposed by the lower energies of the X-rays upon the design and construction of appropriate sample environments. The XMaS beamline at the ESRF has recently made efforts to extend its operational energy range to include this softer end of the X-ray spectrum. In this report the resulting performance of this resource for X-ray spectroscopy is detailed with specific attention drawn to: understanding electrostatic and charge transfer effects at the S K-edge in ionic liquids; quantification of dilution limits at the Cl K- and Rh L3-edges and structural equilibria in solution; in vacuum deposition and reduction of [Rh(I)(CO)2Cl]2 to γ-Al2O3; contamination of γ-Al2O3 by Cl and its potential role in determining the chemical character of supported Rh catalysts; and the development of chlorinated Pd catalysts in `green' solvent systems. Sample environments thus far developed are also presented, characterized and their overall performance evaluated.

  10. Heliospheric Neutral Atom Spectra Between 0.01 and 6 keV fom IBEX

    NASA Technical Reports Server (NTRS)

    Fuselier, S. A.; Allegrini, F.; Bzowski, M.; Funsten, H. O.; Ghielmetti, A. G.; Gloeckler, G.; Heirtzler, D.; Janzen, P.; Kubiak, M.; Kucharek, H.; McComas, D. J.; Moebius, E.; Moore, T. E.; Petrinec, S. M.; Quinn, M.; Reisenfeld, D.; Saul, L. A.; Scheer, J. A.; Schwardron, N.; Trattner, K. J.; Vanderspek, R.; Wurz, P.

    2012-01-01

    Since 2008 December, the Interstellar Boundary Explorer (IBEX) has been making detailed observations of neutrals from the boundaries of the heliosphere using two neutral atom cameras with overlapping energy ranges. The unexpected, yet defining feature discovered by IBEX is a Ribbon that extends over the energy range from about 0.2 to 6 keV. This Ribbon is superposed on a more uniform, globally distributed heliospheric neutral population. With some important exceptions, the focus of early IBEX studies has been on neutral atoms with energies greater than approx. 0.5 keV. With nearly three years of science observations, enough low-energy neutral atom measurements have been accumulated to extend IBEX observations to energies less than approx. 0.5 keV. Using the energy overlap of the sensors to identify and remove backgrounds, energy spectra over the entire IBEX energy range are produced. However, contributions by interstellar neutrals to the energy spectrum below 0.2 keV may not be completely removed. Compared with spectra at higher energies, neutral atom spectra at lower energies do not vary much from location to location in the sky, including in the direction of the IBEX Ribbon. Neutral fluxes are used to show that low energy ions contribute approximately the same thermal pressure as higher energy ions in the heliosheath. However, contributions to the dynamic pressure are very high unless there is, for example, turbulence in the heliosheath with fluctuations of the order of 50-100 km/s.

  11. Amesos 1.0 reference guide.

    SciTech Connect

    Sala, Marzio; Stanley, Ken D.

    2004-05-01

    This document describes the main functionalities of the Amesos package, version 1.0. Amesos, available as part of Trilinos 4.0, provides an object-oriented interface to several serial and parallel sparse direct solvers libraries, for the solution of the linear systems of equations A X = B where A is a real sparse, distributed matrix, defined as an EpetraRowMatrix object, and X and B are defined as EpetraMultiVector objects. Amesos provides a common look-and-feel to several direct solvers, insulating the user from each package's details, such as matrix and vector formats, and data distribution.

  12. TOUGH3 v1.0

    SciTech Connect

    PAU, GEORGE; JUNG, YOOJIN; FINSTERLE, STEFAN; ZHANG, YINGQI

    2016-09-14

    TOUGH3 V1.0 capabilities to simulate multi-dimensional, multi-phase, multi-component, non-isothermal flow and transport in fractured porous media, with applications geosciences and reservoir engineering and other application areas. TOUGH3 V1.0 supports a number of different combinations of fluids and components (updated equation-of-state (EOS) modules from previous versions of TOUGH, including EOS1, EOS2, EOS3, EOS4, EOS5, EOS7, EOS7R, EOS7C, EOS7CA, EOS8, EOS9, EWASG, TMVOC, ECO2N, and ECO2M). This upgrade includes (a) expanded list of updated equation-of-state (EOS) modules, (b) new hysteresis models, (c) new implementation of parallel and solver functionalities, (d) new linear solver options based on PETSc libraries, (e) new automatic build system that automatically downloads and builds third-party libraries and TOUGH3, (f) new printout in CSV format, (g) dynamic memory allocation, (h) various user features, and (i) bug fixes.

  13. Relative biological effectiveness of 280 keV neutrons for apoptosis in human lymphocytes.

    PubMed

    Ryan, L A; Wilkins, R C; McFarlane, N M; Sung, M M; McNamee, J P; Boreham, D R

    2006-07-01

    The relative biological effectiveness (RBE) of neutrons varies from unity to greater than ten depending upon neutron energy and the biological endpoint measured. In our study, we examined apoptosis in human lymphocytes to assess the RBE of low energy 280 keV neutrons compared to Cs gamma radiation and found the RBE to be approximately one. Similar results have been observed for high energy neutrons using the same endpoint. As apoptosis is a major process that influences the consequences of radiation exposure, our results indicate that biological effect and the corresponding weighting factors for 280 keV neutrons may be lower in some cell types and tissues.

  14. LAPACK users` guide: Release 1.0

    SciTech Connect

    Anderson, E.; Bai, Z.; Bischof, C.; Demmel, J.; Dongarra, J.; Du Croz, J.; Greenbaum, A.; Hammarling, S.; McKenney, A.; Ostrouchov, S.; Sorensen, D.

    1992-01-31

    LAPACK is a transportable library of Fortran 77 subroutines for solving the most common problems in numerical linear algebra: systems of linear equations, linear least squares problems, eigenvalue problems and singular value problems. LAPACK is designed to supersede LINPACK and EISPACK, principally by restructuring the software to achieve much greater efficiency on vector processors, high-performance ``superscalar`` workstations, and shared-memory multi-processors. LAPACK also adds extra functionality, uses some new or improved algorithms, and integrates the two sets of algorithms into a unified package. The LAPACK Users` Guide gives an informal introduction to the design of the algorithms and software, summarizes the contents of the package, describes conventions used in the software and documentation, and includes complete specifications for calling the routines. This edition of the Users` guide describes Release 1.0 of LAPACK.

  15. Virtual planets atlas 1.0 freeware

    NASA Astrophysics Data System (ADS)

    Legrand, C.; Chevalley, P.

    2015-10-01

    Since 2002, we develop the "Virtual Moon Atlas -http://www.ap-i.net/avl/en/start" a freeware to help Moon observing and to improve interest for Moon in general public. VMA freeware has been downloaded near 900000 times all over the world and is or has been used by several professional organizations such as Kitt Peak Observatory, National Japan Observatory, Birkbeck College / University College London (K. Joy), BBC Sky at night, several French astronomy magazines and astronomy writers (P. Harrington, S. French...) . Recommended by ESA, registered as educational software by French ministry for education, it has also yet been presented at 2006 & 2007 LPSC and PCC2 in 2011 We have declined this freeware in a new tool with the same goals, but for the telluric planets and satellites, the "Virtual Planets Atlas (VPA / http://www.ap-i.net/avp/en/start") now in version 1.0.

  16. Measurement of the mass attenuation coefficient from 81 keV to 1333 keV for elemental materials Al, Cu and Pb

    NASA Astrophysics Data System (ADS)

    Gjorgieva, Slavica; Barandovski, Lambe

    2016-03-01

    The mass attenuation coefficients (μ/ρ) for 3 high purity elemental materials Al, Cu and Pb were measured in the γ-ray energy range from 81 keV up to 1333 keV using 22Na, 60Co 133Ba and 133Cs as sources of gamma radiation. Well shielded detector (NaI (Tl) semiconductor detector) was used to measure the intensity of the transmitted beam. The measurements were made under condition of good geometry, assuring that any photon absorbed or deflected appreciably does not reach the detector. The measured values are compared with the theoretical ones obtained by Seltzer (1993).

  17. Hyper-filter-fluorescer spectrometer for x-rays above 120 keV

    DOEpatents

    Wang, Ching L.

    1983-01-01

    An apparatus utilizing filter-fluorescer combinations is provided to measure short bursts of high fluence x-rays above 120 keV energy, where there are no practical absorption edges available for conventional filter-fluorescer techniques. The absorption edge of the prefilter is chosen to be less than that of the fluorescer, i.e., E.sub.PRF E.sub.F. In this way, the response function is virtually zero between E.sub.PRF and E.sub.F and well defined and enhanced in an energy band of less than 1000 keV above the 120 keV energy.

  18. DPA Cross Section Library FermiDPA 1.0

    SciTech Connect

    Pronskikh, V. S.; Mokhov, N. V.

    2013-06-05

    DPA cross section library FermiDPA 1.0 based on the industry standard NRT model calculations is described. The library contains DPA cross sections for neutrons in the energy range 10$^{-5}$ eV 20 (150) MeV. Calculations used neutron-induced reaction cross sections from ENDFB-VII database of evaluated nuclear data. The NJOY99 nuclear data processing system's module HEATR was applied to calculate NRT model radiation damage cross sections. The FermiDPA 1.0 library is a database of 395 text files (for 395 known isotopes) with DPA cross sections. It is code-independent and can be implemented in any transport code.

  19. Characteristic 8 keV X rays possess radiobiological properties of higher-LET radiation.

    PubMed

    Shridhar, Ravi; Estabrook, William; Yudelev, Mark; Rakowski, Joseph; Burmeister, Jay; Wilson, George D; Joiner, Michael C

    2010-03-01

    Electronic brachytherapy systems are being developed that can deliver X rays of varying energy depending on the material of a secondary target. A copper target produces characteristic 8 keV X rays. Our aim was to determine whether 8 keV X rays might deliver greater biological effectiveness than megavoltage photons. Cells of the U251 human glioma cell line were used to compare the biological effects of 8 keV X rays and (60)Co gamma rays in terms of relative biological effectiveness (RBE), oxygen enhancement ratio (OER), and DNA damage. The RBE at 50% and 10% survival was 2.6 and 1.9, respectively. At 50% survival, the OER for cells treated with 8 keV X rays was 1.6 compared with 3.0 for (60)Co gamma rays. The numbers of H2AX foci per Gy after treatment with 8 keV X rays and (60)Co gamma rays were similar; however, the size of the foci generated at 8 keV was significantly larger, possibly indicating more complex DNA damage. The mean area of H2AX foci generated by 8 keV X rays was 0.785 microm(2) (95% CI: 0.756-0.814) compared with 0.491 microm(2) (95% CI: 0.462-0.520) for (60)Co gamma rays (P < 0.0001). Characteristic 8 keV X rays produce two to three times the biological effectiveness of megavoltage photons, with a radiobiological profile similar to higher-LET radiations.

  20. Microgrid Sizing Capability v 1.0

    SciTech Connect

    2015-11-20

    The MSC is an optimization model, written in Python, that is used to make an initial determination of the types and quantities of electric power generation and energy storage technologies that should be purchased when developing a microgrid. In addition to determining which technologies to purchase, the model determines the optimal policies for operating the microgrid. The model selects the purchases and operating polices in a manner that minimizes annual energy costs (operating costs plus annualized capital costs), while ensuring that that the purchased technologies are paid back within a reasonable timeframe.

  1. Sensors Umbra Package v 1.0

    SciTech Connect

    Oppel, Fred J.; Hart, Brian E.; Whitford, Gregg Douglas; Xavier, Patrick G.; Rigdon, James Brian; Gottlieb, Eric Joseph; McDonald, Michael J.; Hart, Derek H.; Jungels, John; Little, Charles Q.

    2016-08-25

    This package contains modules that model sensors in Umbra. There is a mix of modalities for both accumulating and tracking energy sensors: seismic, magnetic, and radiation. Some modules fuss information from multiple sensor types. Sensor devices (e.g., seismic sensors), detect objects such as people and vehicles that have sensor properties attached (e.g., seismic properties).

  2. Coulomb Logarithm, Version 1.0

    SciTech Connect

    Singleton, Robert

    2016-11-23

    Clog is a library of charged particle stopping powers and related Coulomb logarithm processes in a plasma. The stopping power is a particularly useful quantity for plasma physics, as it measures the energy loss of per unit length of charged particle as it traverses a plasma. Clog's primary stopping power is the BPS (Brown-Preston-Singleton) theory.

  3. Preparation for B4C/Mo2C multilayer deposition of alternate multilayer gratings with high efficiency in the 0.5-2.5 keV energy range

    NASA Astrophysics Data System (ADS)

    Choueikani, Fadi; Delmotte, Franck; Bridou, Françoise; Lagarde, Bruno; Mercere, Pascal; Otero, Edwige; Ohresser, Philippe; Polack, François

    2013-03-01

    This paper presents a study of B4C/Mo2C multilayers mirrors with the aim of using it in the achievement of Alternate MultiLayer (AML) grating. Such component allows a high efficiency in the 500-2500 eV energy range for the DEIMOS beamline. Multilayers were deposited on silicon substrate. They are characterized by reflectometry under grazing incidence. Numerical adjustments were performed with a model of two layers in the period without any interfacial. A prototype of AML grating was fabricated and characterized. The efficiency of the first order of diffraction was worth 15% at 1700 eV.

  4. Influence of organic ions on DNA damage induced by 1 eV to 60 keV electrons.

    PubMed

    Zheng, Yi; Sanche, Léon

    2010-10-21

    We report the results of a study on the influence of organic salts on the induction of single strand breaks (SSBs) and double strand breaks (DSBs) in DNA by electrons of 1 eV to 60 keV. Plasmid DNA films are prepared with two different concentrations of organic salts, by varying the amount of the TE buffer (Tris-HCl and EDTA) in the films with ratio of 1:1 and 6:1 Tris ions to DNA nucleotide. The films are bombarded with electrons of 1, 10, 100, and 60 000 eV under vacuum. The damage to the 3197 base-pair plasmid is analyzed ex vacuo by agarose gel electrophoresis. The highest yields are reached at 100 eV and the lowest ones at 60 keV. The ratios of SSB to DSB are surprisingly low at 10 eV (∼4.3) at both salt concentrations, and comparable to the ratios measured with 100 eV electrons. At all characteristic electron energies, the yields of SSB and DSB are found to be higher for the DNA having the lowest salt concentration. However, the organic salts are more efficient at protecting DNA against the damage induced by 1 and 10 eV electrons. DNA damage and protection by organic ions are discussed in terms of mechanisms operative at each electron energy. It is suggested that these ions create additional electric fields within the groove of DNA, which modify the resonance parameter of 1 and 10 eV electrons, namely, by reducing the electron capture cross-section of basic DNA units and the lifetime of corresponding transient anions. An interstrand electron transfer mechanism is proposed to explain the low ratios for the yields of SSB to those of DSB produced by 10 eV electrons.

  5. Influence of organic ions on DNA damage induced by 1 eV to 60 keV electrons

    SciTech Connect

    Zheng Yi; Sanche, Leon

    2010-10-21

    We report the results of a study on the influence of organic salts on the induction of single strand breaks (SSBs) and double strand breaks (DSBs) in DNA by electrons of 1 eV to 60 keV. Plasmid DNA films are prepared with two different concentrations of organic salts, by varying the amount of the TE buffer (Tris-HCl and EDTA) in the films with ratio of 1:1 and 6:1 Tris ions to DNA nucleotide. The films are bombarded with electrons of 1, 10, 100, and 60 000 eV under vacuum. The damage to the 3197 base-pair plasmid is analyzed ex vacuo by agarose gel electrophoresis. The highest yields are reached at 100 eV and the lowest ones at 60 keV. The ratios of SSB to DSB are surprisingly low at 10 eV ({approx}4.3) at both salt concentrations, and comparable to the ratios measured with 100 eV electrons. At all characteristic electron energies, the yields of SSB and DSB are found to be higher for the DNA having the lowest salt concentration. However, the organic salts are more efficient at protecting DNA against the damage induced by 1 and 10 eV electrons. DNA damage and protection by organic ions are discussed in terms of mechanisms operative at each electron energy. It is suggested that these ions create additional electric fields within the groove of DNA, which modify the resonance parameter of 1 and 10 eV electrons, namely, by reducing the electron capture cross-section of basic DNA units and the lifetime of corresponding transient anions. An interstrand electron transfer mechanism is proposed to explain the low ratios for the yields of SSB to those of DSB produced by 10 eV electrons.

  6. Influence of organic ions on DNA damage induced by 1 eV to 60 keV electrons

    NASA Astrophysics Data System (ADS)

    Zheng, Yi; Sanche, Léon

    2010-10-01

    We report the results of a study on the influence of organic salts on the induction of single strand breaks (SSBs) and double strand breaks (DSBs) in DNA by electrons of 1 eV to 60 keV. Plasmid DNA films are prepared with two different concentrations of organic salts, by varying the amount of the TE buffer (Tris-HCl and EDTA) in the films with ratio of 1:1 and 6:1 Tris ions to DNA nucleotide. The films are bombarded with electrons of 1, 10, 100, and 60 000 eV under vacuum. The damage to the 3197 base-pair plasmid is analyzed ex vacuo by agarose gel electrophoresis. The highest yields are reached at 100 eV and the lowest ones at 60 keV. The ratios of SSB to DSB are surprisingly low at 10 eV (˜4.3) at both salt concentrations, and comparable to the ratios measured with 100 eV electrons. At all characteristic electron energies, the yields of SSB and DSB are found to be higher for the DNA having the lowest salt concentration. However, the organic salts are more efficient at protecting DNA against the damage induced by 1 and 10 eV electrons. DNA damage and protection by organic ions are discussed in terms of mechanisms operative at each electron energy. It is suggested that these ions create additional electric fields within the groove of DNA, which modify the resonance parameter of 1 and 10 eV electrons, namely, by reducing the electron capture cross-section of basic DNA units and the lifetime of corresponding transient anions. An interstrand electron transfer mechanism is proposed to explain the low ratios for the yields of SSB to those of DSB produced by 10 eV electrons.

  7. The Morphology of the X-ray Emission above 2 keV from Jupiter's Aurorae

    NASA Technical Reports Server (NTRS)

    Elsner, R.; Branduardi-Raymont, G.; Galand, M.; Grodent, D.; Waite, J. H.; Cravens, T.; Ford, P.

    2007-01-01

    The discovery in XMM-Newton X-ray data of X-ray emission above 2 keV from Jupiter's aurorae has led us to reexamine the Chandra ACIS-S observations taken in Feb 2003. Chandra's superior spatial resolution has revealed that the auroral X-rays with E > 2 keV are emitted from the periphery of the region emitting those with E < 1 keV. We are presently exploring the relationship of this morphology to that of the FUV emission from the main auroral oval and the polar cap. The low energy emission has previously been established as due to charge exchange between energetic precipitating ions of oxygen and either sulfur or carbon. It seems likely to us that the higher energy emission is due to precipitation of energetic electrons, possibly the same population of electrons responsible for the FUV emission. We discuss our analysis and interpretation.

  8. Static and time-resolved 10-1000 keV x-ray imaging detector options for NIF

    SciTech Connect

    Landen, O.L.; Bell, P.M.; McDonald, J.W.; Park, H.-S.; Weber, F.; Moody, J.D.; Lowry, M.E.; Stewart, R.E.

    2004-10-01

    High energy (>10 keV) x-ray self-emission imaging and radiography will be essential components of many NIF high energy density physics experiments. In preparation for such experiments, we have evaluated the pros and cons of various static [x-ray film, bare charge-coupled device (CCD), and scintillator + CCD] and time-resolved (streaked and gated) 10-1000 keV detectors.

  9. HEAO 1 high-energy X-ray observations of three bright transient X-ray sources H1705-250 (Nova Ophiuchi), H1743-322, and H1833-077 (Scutum X-1)

    NASA Technical Reports Server (NTRS)

    Cooke, B. A.; Levine, A. M.; Lang, F. L.; Primini, F. A.; Lewin, W. H. G.

    1984-01-01

    The bright X-ray transients H1705-250 (Nova Ophiuchi) and H1743-322 in the energy range 12-180 keV were observed, and the presence of high-energy spectral components was revealed. On the basis of X-ray spectra in the 1-10 keV range, transients are classified as 'soft' (kT = 4 keV) or 'hard' (kT = 17 keV); and both H1705-250 and H1743-322 should be in the 'soft' category. Data have been reexamined for the archetypal 'soft' transient A0600-00 taken by the SAS 3 satellite, but no evidence is found there for a high-energy spectral component. Thus consideration of a wider X-ray energy range makes the 'hard'/'soft' distinction between X-ray transients much less clear.

  10. Bill Calculator V1.0

    SciTech Connect

    2002-08-19

    Utitlity tariffs vary significantly from utility to utility. Each utility has its own rates and sets of rules by which bills are calculated. The Bill Calculator reconstructs the tariff based on these rules, stored in data tables, and access the appropriate charges for a given energy consumption and demand. The software reconstructs the tariff logic from the rules stored in data tables. Changes are tallied as the logic is reconstructed. This is essentially an accounting program. The main limitation is on the time to search for each tariff element. It is currently on O(N) search. Also, since the Bill calculator first stores all tariffs in an array and then reads the array to reconstruct a specific tariff, the memory limitatins of a particular system would limit the number of tariffs that could be handled. This tool allows a user to calculate a bill from any sampled utility without prior knowledge of the tariff logic or structure. The peculiarities of the tariff logic are stored in data tables and manged by the Bill Calculator software. This version of the software is implemented as a VB module that operates within Microsoft Excel. Input data tables are stored in Excel worksheets. In this version the Bill Calculator functions can be assessed through Excel as user defined worksheet functions. Bill Calculator can calculate approximately 50,000 bills in less than 30 minutes.

  11. Study on the parameters of the scanning system for the 300 keV electron accelerator

    SciTech Connect

    Leo, K. W.; Chulan, R. M. Hashim, S. A.; Baijan, A. H.; Sabri, R. M.; Mohtar, M.; Glam, H.; Lojius, L.; Zahidee, M.; Azman, A.; Zaid, M.

    2016-01-22

    This paper describes the method to identify the magnetic coil parameters of the scanning system. This locally designed low energy electron accelerator with the present energy of 140 keV will be upgraded to 300 keV. In this accelerator, scanning system is required to deflect the energetic electron beam across a titanium foil in vertical and horizontal direction. The excitation current of the magnetic coil is determined by the energy of the electron beam. Therefore, the magnetic coil parameters must be identified to ensure the matching of the beam energy and excitation coil current. As the result, the essential parameters of the effective lengths for X-axis and Y-axis have been found as 0.1198 m and 0.1134 m and the required excitation coil currents which is dependenton the electron beam energies have be identified.

  12. Crash Impact Demonstration. (pt 1/10)

    NASA Technical Reports Server (NTRS)

    1984-01-01

    This clip: Front view, long shot. The model scenario is gone, as the plane impacts short of the target area and port wing first, skidding to the left. With narration. Background: On December 1st, 1984, a remote controlled 4 engined transport jet took off from Edwards AFB, CA and crashed into a barren patch of nearby desert. This Controlled Impact Demonstration was a joint R&D program by the FAA and NASA. The FAA designed the C.I.D. to underscore results of exhaustive research in two areas of aircraft safety: improved crash protection and reduced post-crash fire hazards.Despite the fact the crash did not go exactly as designed C.I.D.did achieve its primary objectives.The analysis of C.I.D. data continues. The CID's crash wothiness tests were as important to the FAA as the fire safety tests. The crash protection objectives were: 1st: To obtain data on impact forces and their transmission thru the structure to the seats and occupants. 2nd: To evaluate the performance of existing and advanced energy absorbing seats. 3rd :To compare tests used to predict structural behaviour with an actual crash. AMK (anti-misting kerosene) fuel was employed in the test. The FAA has examined AMK's potential for protecting commercial transports from ignition of misted fuels. All research indicated that AMK would be effective in preventing this problem. The C.I.D. was an opportunity to use AMK in a realistic, impact-survivable crash.

  13. The Search for 17-KEV Neutrino Emission in the Beta-Decay Spectrum of SULFUR-35.

    NASA Astrophysics Data System (ADS)

    Berman, Gregg Evan

    For this work, the electron momentum spectrum resulting from the beta-decay of ^{35}S, ^{35}{rm S} to ^ {35}{rm Cl} + {rm e }^- + |nu_{rm e}quad (E_0 - m_{e} = 167 {rm keV, T}_{1/2 } = 87.4 {rm days}), has been measured in order to search for the presence of 17-keV electron neutrino emission. Originally observed by J. Simpson in 1985, evidence supporting a 1% 17-keV neutrino branch in the decay spectra of ^3 H, ^{35}S, ^{63}Ni, ^{55 }Fe, ^{14}C and ^{71}Ge has since been reported. However, other groups observing these nuclei have not seen any evidence of 17-keV neutrino emission, and very stringent limits ruling out a 1% branch have been published. Therefore, an important goal of this work is to reduce and/or understand experimental systematic errors that can mask or mimic the effects of a 17-keV neutrino. This ^{35}S spectrum measurement was performed using Princeton's extensively renovated, iron-free, intermediate-image, magnetic spectrometer. To ensure radio-chemical purity, the ^{35 }S source was prepared by ion-implantation using an isotope separator. To accurately determine the overall response of the spectrometer, electron data was accumulated over the very wide energy range of 40-167 keV. In addition, a detailed study of the spectrometer response using various ^{111}In calibration sources was undertaken, and the effects of source positioning and background magnetic fields have been explored. Furthermore, new computer codes for electron orbit raytracing and Monte-Carlo simulations have been developed to help further study the response of the spectrometer as well as to predict the effects of electron backscattering in both the source and detector substrates. To analyze the experimental data for the presence of a 17-keV neutrino branch, the measured ^ {35}S spectrum was convolved with the overall response of the spectrometer, and then fit by least -squares reduction to a theoretical beta -decay shape that allows heavy-neutrino mixing. The results show that the

  14. Theoretical Form Factor, Attenuation, and Scattering Tabulation for Z=1-92 from E=1-10 eV to E=0.4-1.0 MeV

    NASA Astrophysics Data System (ADS)

    Chantler, C. T.

    1995-01-01

    Tables for form factors and anomalous dispersion are widely used in the UV, x-ray, and y-ray communities, and have existed for a considerable period of time. Much of the recent theoretical basis for these was contributed by Cromer, Mann, and Liberman while much of the experimental data were synthesized by Henke et al. More recent developments in both areas have led to new and revised tables. These works have employed numerous simplifications compared to detailed relativistic S-matrix calculations; the latter do not lend themselves to convenient tabular application for the range of Z and energy of general interest. Conversely, the former tables appear to have large regions of limited validity throughout the range of Z and energies, and in particular have important limitations with regard to extrapolation to energies outside tabulated ranges. In the present study, the primary interactions of x-rays with isolated atoms from Z=1 (hydrogen) to Z=92 (uranium) are described and computed within a self-consistent Dirac-Hartree-Fock framework. This has general application across the range of energy from 1-10 eV to 400-1000 keV, with limitations (described below) as the low- and high-energy extremes are approached. Tabulations are provided for the f1 and f2 components of the form factors, together with the photoelectric attenuation coefficient for the atom, μ, and the value for the K-shell, μK, as functions of energy and wavelength. Also provided are estimated correction factors as described in the text, conversion factors, and a simple estimate for the sum of the scattering contributions (from an isolated atom). The method used herein is primarily theoretical and considers intermediate assumptions which limit the precision and applicability of previous theoretical tabulations. Particular concern involves the application of the dispersion relation to derive Re(f) from photoelectric absorption cross-sections. The revised formulation presented here explicitly avoids most of

  15. Network Centric Operations Conceptual Framework Version 1.0

    DTIC Science & Technology

    2003-11-01

    Network Centric Operations Conceptual Framework Version 1.0 Prepared for: John Garstka Office of Force Transformation Prepared by...COVERED 00-11-2003 to 00-11-2003 4. TITLE AND SUBTITLE Network Centric Operations Conceptual Framework Version 1.0 5a. CONTRACT NUMBER 5b. GRANT... Conceptual Framework Version 1.0 Table of Contents 1.0 Introduction and Background

  16. Solar wind ions accelerated to 40 keV by shock wave disturbances

    NASA Astrophysics Data System (ADS)

    Gosling, J. T.; Asbridge, J. R.; Bame, S. J.; Feldman, W. C.; Paschmann, G.; Sckopke, N.

    1980-02-01

    Observations in the solar wind with the LASL/MPI fast plasma experiment on ISEE 1 and 2 reveal the common presence of ions with energies extending from 100 eV up to at least 40 keV in a broad region, typically 10 million kilometers wide, following interplanetary shocks. Peak differential fluxes up to 5000/sq cm s sr keV at 28 keV are observed either at the shock or within the first 1.5 hours following shock passage. In the solar wind frame the distribution function of these ions is roughly isotropic, peaks near zero velocity, and above 5 keV can adequately be characterized as power law in energy with a spectral index of 2.7. The effective 'temperature' of these ions generally exceeds 100 million K. These suprathermal interplanetary ions are almost certainly solar wind ions which have been accelerated by some mechanism associated with the shock wave disturbance. Present evidence leads the authors to favor stochastic particle acceleration involving electrostatic and/or electromagnetic turbulence in the postshock flow.

  17. The Solar Flare 4: 10 keV X-ray Spectrum

    NASA Technical Reports Server (NTRS)

    Phillips, K. J. H.

    2004-01-01

    The 4-10 keV solar flare spectrum includes highly excited lines of stripped Ca, Fe, and Ni ions as well as a continuum steeply falling with energy. Groups of lines at approximately 7 keV and approximately 8 keV, observed during flares by the broad-band RHESSI spectrometer and called here the Fe-line and Fe/Ni-line features, are formed mostly of Fe lines but with Ni lines contributing to the approximately 8 keV feature. Possible temperature indicators of these line features are discussed - the peak or centroid energies of the Fe-line feature, the line ratio of the Fe-line to the Fe/Ni-line features, and the equivalent width of the Fe-line feature. The equivalent width is by far the most sensitive to temperature. However, results will be confused if, as is commonly believed, the abundance of Fe varies from flare to flare, even during the course of a single flare. With temperature determined from the thermal continuum, the Fe-line feature becomes a diagnostic of the Fe abundance in flare plasmas. These results are of interest for other hot plasmas in coronal ionization equilibrium such as stellar flare plasmas, hot gas in galaxies, and older supernova remnants.

  18. 41 CFR 60-1.10 - Foreign government practices.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 41 Public Contracts and Property Management 1 2013-07-01 2013-07-01 false Foreign government practices. 60-1.10 Section 60-1.10 Public Contracts and Property Management Other Provisions Relating to... Clause; Compliance Reports § 60-1.10 Foreign government practices. Contractors shall not discriminate...

  19. 45 CFR 1211.1-10 - Informal grievance procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 4 2011-10-01 2011-10-01 false Informal grievance procedure. 1211.1-10 Section 1211.1-10 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE VOLUNTEER GRIEVANCE PROCEDURES § 1211.1-10 Informal grievance procedure. (a) Initiation of grievance. A volunteer may initiate...

  20. Using a delta-doped CCD to determine the energy of a low-energy particle

    NASA Technical Reports Server (NTRS)

    Nikzad, Shouleh (Inventor); Croley, Donald R. (Inventor); Murphy, Gerald B. (Inventor)

    2001-01-01

    The back surface of a thinned charged-coupled device (CCD) is treated to eliminate the backside potential well that appears in a conventional thinned CCD during backside illumination. The backside of the CCD includes a delta layer of high-concentration dopant confined to less than one monolayer of the crystal semiconductor. The thinned, delta-doped CCD is used to determine the energy of a very low-energy particle that penetrates less than 1.0 nm into the CCD, such as a proton having energy less than 10 keV.

  1. The diffuse X-ray spectrum from 14-200 keV as measured on OSO-5

    NASA Technical Reports Server (NTRS)

    Dennis, B. R.; Suri, A. N.; Frost, K. J.

    1973-01-01

    The measurement of energy spectrum of the diffuse component of cosmic X-ray flux made on the OSO-5 spacecraft is described. The contributions to the total counting rate of the actively shielded X-ray detector are considered in some detail and the techniques used to eliminate the non-cosmic components are described. Positive values for the cosmic flux are obtained in seven energy channels between 14 and 200 keV and two upper limits are obtained between 200 and 254 keV. The results can be fitted by a power law spectrum. A critical comparison is made with the OSO-3 results. Conclusions show that the reported break in the energy spectrum at 40 keV is probably produced by an erroneous correction for the radioactivity induced in the detector on each passage through the intense charged particle fluxes in the South Atlantic anomaly.

  2. The Morphology of the X-ray Emission above 2 keV from Jupiter's Aurorae

    NASA Technical Reports Server (NTRS)

    Elsner, R.; Branduardi-Raymont, G.; Galand, M.; Grodent, D.; Gladstone, G. R.; Waite, J. H.; Cravens, T.; Ford, P.

    2007-01-01

    The discovery in XMM-Newton X-ray data of X-ray emission above 2 keY from Jupiter's aurorae has led us to reexamine the Chandra ACIS-S observations taken in Feb 2003. Chandra's superior spatial resolution has revealed that the auroral X-rays with E > 2 keV are emitted from the periphery of the region emitting those with E < 1 keV. We are presently exploring the relationship of this morphology to that of the FUV emission from the main auroral oval and the polar cap. The low energy emission has previously been established as due to charge exchange between energetic precipitating ions of oxygen and either sulfur or carbon. It seems likely to us that the higher energy emission is due to precipitation of energetic electrons, possibly the same population of electrons responsible for the FUV emission. We discuss our analysis and interpretation.

  3. Implications of the 17 keV neutrino

    SciTech Connect

    Hall, L.J.

    1991-06-01

    Constraints on the theoretical interpretation of the 17 keV neutrino are reviewed. A simple understanding of the 17 keV neutrino is provided by flavon models, which involve the spontaneous breaking of Abelian lepton symmetries and have only the usual three light neutrino species. Signatures for this class of models include neutrino oscillations, tau decay to an electron and a flavon, and invisible decay modes of the Higgs boson to two flavons.

  4. Compton polarimeter for 10-30 keV x rays

    NASA Astrophysics Data System (ADS)

    Weber, S.; Beilmann, C.; Shah, C.; Tashenov, S.

    2015-09-01

    We present a simple and versatile polarimeter for x rays in the energy range of 10-30 keV. It uses Compton scattering in low-Z materials such as beryllium or boron carbide. The azimuthal distribution of the scattered x rays is sampled by an array of 12 silicon PIN diodes operated at room temperature. We evaluated the polarimetry performance using Monte-Carlo simulations and show experimental results.

  5. Compton polarimeter for 10–30 keV x rays

    SciTech Connect

    Weber, S.; Beilmann, C.; Shah, C.; Tashenov, S.

    2015-09-15

    We present a simple and versatile polarimeter for x rays in the energy range of 10–30 keV. It uses Compton scattering in low-Z materials such as beryllium or boron carbide. The azimuthal distribution of the scattered x rays is sampled by an array of 12 silicon PIN diodes operated at room temperature. We evaluated the polarimetry performance using Monte-Carlo simulations and show experimental results.

  6. The soft X-ray diffuse background observed with the HEAO 1 low-energy detectors

    NASA Technical Reports Server (NTRS)

    Garmire, G. P.; Nousek, J. A.; Apparao, K. M. V.; Burrows, D. N.; Fink, R. L.; Kraft, R. P.

    1992-01-01

    Results of a study of the diffuse soft-X-ray background as observed by the low-energy detectors of the A-2 experiment aboard the HEAO 1 satellite are reported. The observed sky intensities are presented as maps of the diffuse X-ray background sky in several energy bands covering the energy range 0.15-2.8 keV. It is found that the soft X-ray diffuse background (SXDB) between 1.5 and 2.8 keV, assuming a power law form with photon number index 1.4, has a normalization constant of 10.5 +/- 1.0 photons/sq cm s sr keV. Below 1.5 keV the spectrum of the SXDB exceeds the extrapolation of this power law. The low-energy excess for the NEP can be fitted with emission from a two-temperature equilibrium plasma model with the temperatures given by log I1 = 6.16 and log T2 = 6.33. It is found that this model is able to account for the spectrum below 1 keV, but fails to yield the observed Galactic latitude variation.

  7. The RAND 36-Item Health Survey 1.0.

    PubMed

    Hays, R D; Sherbourne, C D; Mazel, R M

    1993-10-01

    Recently, Ware and Sherbourne published a new short-form health survey, the MOS 36-Item Short-Form Health Survey (SF-36), consisting of 36 items included in long-form measures developed for the Medical Outcomes Study. The SF-36 taps eight health concepts: physical functioning, bodily pain, role limitations due to physical health problems, role limitations due to personal or emotional problems, general mental health, social functioning, energy/fatigue, and general health perceptions. It also includes a single item that provides an indication of perceived change in health. The SF-36 items and scoring rules are distributed by MOS Trust, Inc. Strict adherence to item wording and scoring recommendations is required in order to use the SF-36 trademark. The RAND 36-Item Health Survey 1.0 (distributed by RAND) includes the same items as those in the SF-36, but the recommended scoring algorithm is somewhat different from that of the SF-36. Scoring differences are discussed here and new T-scores are presented for the 8 multi-item scales and two factor analytically-derived physical and mental health composite scores.

  8. SLR-PLUS version 1.0 user's manual

    NASA Astrophysics Data System (ADS)

    Hill, J. M.

    1982-11-01

    Version 1.0 of Solar Load Ratio heating plus cooling (SLR-PLUS), developed as an advanced passive solar system design and evaluation tool, is discussed. SLR-PLUS maintains the friendly user interface structure developed for the active solar system FCHART program. Users familiar with the FCHART programs and the FCHART/SLR program will find the operation of the SLR-PLUS program very familiar SLR-PLUS differs significantly from its parent program in three major ways. First, SLR-PLUS is strictly for the evaluation of passive solar energy systems. Second, the latest correlations from the Los Alamos National Laboratory serve as the basis to the passive heating analysis used by SLR-PLUS. Finally, SLR-PLUS includes cooling loads imposed by passive systems in the form of an annual cooling load for the building modelled and for the individual passive systems. The present version was developed on an Hewlett-Packard 1000 minicomputer using an RTE-IVB operating system. The present version requires approximately 22K 16-bit words of core with overlays to run. The FORTRAN source code will compile with minor changes on any FORTRAN 77 compiler.

  9. New Observations of Soft X-ray (0.5-5 keV) Solar Spectra

    NASA Astrophysics Data System (ADS)

    Caspi, A.; Woods, T. N.; Mason, J. P.; Jones, A. R.; Warren, H. P.

    2013-12-01

    The solar corona is the brightest source of X-rays in the solar system, and the X-ray emission is highly variable on many time scales. However, the actual solar soft X-ray (SXR) (0.5-5 keV) spectrum is not well known, particularly during solar quiet periods, as, with few exceptions, this energy range has not been systematically studied in many years. Previous observations include high-resolution but very narrow-band spectra from crystal spectrometers (e.g., Yohkoh/BCS), or integrated broadband irradiances from photometers (e.g., GOES/XRS, TIMED/XPS, etc.) that lack detailed spectral information. In recent years, broadband measurements with moderate energy resolution (~0.5-0.7 keV FWHM) were made by SphinX on CORONAS-Photon and SAX on MESSENGER, although they did not extend to energies below ~1 keV. We present observations of solar SXR emission obtained using new instrumentation flown on recent SDO/EVE calibration rocket underflights. The photon-counting spectrometer, a commercial Amptek X123 with a silicon drift detector and an 8 μm Be window, measures the solar disk-integrated SXR emission from ~0.5 to >10 keV with ~0.15 keV FWHM resolution and 1 s cadence. A novel imager, a pinhole X-ray camera using a cooled frame-transfer CCD (15 μm pixel pitch), Ti/Al/C filter, and 5000 line/mm Au transmission grating, images the full Sun in multiple spectral orders from ~0.1 to ~5 nm with ~10 arcsec/pixel and ~0.01 nm/pixel spatial and spectral detector scales, respectively, and 10 s cadence. These instruments are prototypes for future CubeSat missions currently being developed. We present new results of solar observations on 04 October 2013 (NASA sounding rocket 36.290). We compare with previous results from 23 June 2012 (NASA sounding rocket 36.286), during which solar activity was low and no signal was observed above ~4 keV. We compare our spectral and imaging measurements with spectra and broadband irradiances from other instruments, including SDO/EVE, GOES/XRS, TIMED

  10. Mutagenic effect of a keV range N + beam on mammalian cells

    NASA Astrophysics Data System (ADS)

    Feng, Huiyun; Wu, Lijun; Yu, Lixiang; Han, Wei; Liu, Xuelan; Yu, Zengliang

    2005-07-01

    The radiobiological effects of a keV (5-20 keV) range nitrogen ion (N +) beam on mammalian cells were studied, particularly with regard to the induction of mutation in the cell genome. The experiment demonstrated that the 20 keV N + beam, which resulted in cell death to a certain extent, induced a 2-3 fold increase in the mutation rates at the CD59 gene locus of the mammalian A L cells as compared to the control. Within certain fluence ranges (0-6 × 10 14 N +/cm 2), the cell survival displayed a down-up-down pattern which is similar to the phenomenon known as 'hyper-radiosensitivity' manifested under low-dose irradiation; the CD59 mutation rate firstly showed a gradual rise up to a 3-fold increment above the background level as the ion fluence went up to 4 × 10 14 N +/cm 2, after this peak point however, a downtrend appeared though the ion fluence increased further. It was also observed that the fraction of CD59 mutation bears no proportional relation to ion energy in further experiments of mutation induction by N + beams with the incident energies of 5, 10, 15 and 20 keV at the same fluence of 3 × 10 14 N +/cm 2. Analyses of the deletion patterns of chromosome 11 in CD59- mutants induced by 5-20 keV N + beams showed that these ions did not result in large-size chromosome deletions in this mammalian cell system. A preliminary discussion, suggesting that the mutagenic effect of such low-energy ion influx on mammalian cells could result from multiple processes involving direct collision of particles with cellular DNA, and cascade atomic and molecular reactions due to plentiful primary and secondary particles, was also presented. The study provided the first glimpse into the roles low-energy ions may play in inducing mutagenesis in mammalian cells, and results will be of much value in helping people to understand the contribution of low-energy ions to radiological effects of various ionising radiations.

  11. A Compton camera for spectroscopic imaging from 100keV to 1MeV

    NASA Astrophysics Data System (ADS)

    Earnhart, Jonathan Raby Dewitt

    The objective of this work is to investigate Compton camera technology for spectroscopic imaging of gamma rays in the 100keV to 1MeV range. An efficient, specific purpose Monte Carlo code was developed to investigate the image formation process in Compton cameras. The code is based on a pathway sampling technique with extensive use of variance reduction techniques. The code includes detailed Compton scattering physics, including incoherent scattering functions, Doppler broadening, and multiple scattering. Experiments were performed with two different camera configurations for a scene containing a 75Se source and a 137Cs source. The first camera was based on a fixed silicon detector in the front plane and a CdZnTe detector mounted in the stage. The second camera configuration was based on two CdZnTe detectors. Both systems were able to reconstruct images of 75Se, using the 265keV line, and 137Cs, using the 662keV line. Only the silicon-CdZnTe camera was able to resolve the low intensity 400keV line of 75Se. Neither camera was able to reconstruct the 75Se source location using the 136keV line. The energy resolution of the silicon-CdZnTe camera system was 4% at 662keV. This camera reproduced the location of the 137Cs source by event circle image reconstruction with angular resolutions of 10° for a source on the camera axis and 14° for a source 30° off axis. Typical detector pair efficiencies were measured as 3 x 10-11 at 662keV. The dual CdZnTe camera had an energy resolution of 3.2% at 662keV. This camera reproduced the location of the 137Cs source by event circle image reconstruction with angular resolutions of 8° for a source on the camera axis and 12° for a source 20° off axis. Typical detector pair efficiencies were measured as 7 x 10-11 at 662keV. Of the two prototype camera configurations tested, the silicon-CdZnTe configuration had superior imaging characteristics. This configuration is less sensitive to effects caused by source decay cascades and random

  12. Evaluation of 238U Resonance Parameters from 0 to 20 keV

    SciTech Connect

    Derrien, H.; Leal, L.C.; Larson, N.; Courcelle, A.; Santamarina, A.

    2005-05-24

    The neutron resonance parameters of 238U were obtained in the energy range 0 to 20 keV from a sequential SAMMY analysis of the most recent high-resolution neutron transmission and neutron capture cross-section measurements. Special care was taken in the analysis of the lowest s-wave resonances leading to resonance parameters slightly different from those of ENDF/B-VI (Moxon-Sowerby resonance parameters). The resolved-resonance range was extended to 20 keV, taking advantage of the high-resolution neutron transmission data of Harvey and neutron capture data of Macklin et al. Preliminary integral tests were performed with the new resonance parameters; thermal low-enriched benchmark calculations show an improvement of the keff prediction, mainly due to a 1.5% decrease of the capture cross section at 0.0253 eV and about a 0.4% decrease of the effective shielded resonance capture integral.

  13. Microbeam of 100 keV x ray with a sputtered-sliced Fresnel zone plate

    NASA Astrophysics Data System (ADS)

    Kamijo, Nagao; Suzuki, Yoshio; Takano, Hidekazu; Tamura, Shigeharu; Yasumoto, Masato; Takeuchi, Akihisa; Awaji, Mitsuhiro

    2003-12-01

    Microfocusing of 100 keV x ray with a sputtered-sliced Fresnel zone plate (ss-FZP) has been performed at the 250-m-long beamline (20XU) of SPring-8. The ss-FZP with an outermost zone width 0.16 μm which is composed of 70 layers of alternating Cu and Al layers and having thickness ˜180 μm was fabricated and characterized. The minimum focal spot size attained for the first order focal beam was 0.5 μm with a focal distance 900 mm at a photon energy 100 keV. The total flux of the microprobe was ˜2×106 photons s-1 μm-2.

  14. State-selective electron capture in 30- and 100-keV He++He collisions

    NASA Astrophysics Data System (ADS)

    Guo, D. L.; Ma, X.; Zhang, R. T.; Zhang, S. F.; Zhu, X. L.; Feng, W. T.; Gao, Y.; Hai, B.; Zhang, M.; Wang, H. B.; Huang, Z. K.

    2017-01-01

    A combined experimental and theoretical study on single capture in 30- and 100-keV He+ on He collisions was performed. By using a reaction microscope, we obtained the state selective cross sections and the angular-differential cross sections. It was found that the experimental state-selective cross sections were in good agreement with the dynamic screening classical trajectory Monte Carlo calculation for 100-keV He+ incident. The comparisons with various versions of such calculations reveal the roles played by different electron-electron correlation effects. Moreover, a prominent oscillatory structure was observed in the angular-differential cross sections for both projectile energies. With the single capture probability distribution obtained from the classical trajectory Monte Carlo calculation, the oscillation structures can be well explained by atomic-size Fraunhofer-type diffraction.

  15. Compact, maintainable 80-KeV neutral beam module

    DOEpatents

    Fink, Joel H.; Molvik, Arthur W.

    1980-01-01

    A compact, maintainable 80-keV arc chamber, extractor module for a neutral beam system immersed in a vacuum of <10.sup.-2 Torr, incorporating a nested 60-keV gradient shield located midway between the high voltage ion source and surrounding grounded frame. The shield reduces breakdown or arcing path length without increasing the voltage gradient, tends to keep electric fields normal to conducting surfaces rather than skewed and reduces the peak electric field around irregularities on the 80-keV electrodes. The arc chamber or ion source is mounted separately from the extractor or ion accelerator to reduce misalignment of the accelerator and to permit separate maintenance to be performed on these systems. The separate mounting of the ion source provides for maintaining same without removing the ion accelerator.

  16. Hitomi Constraints on the 3.5 keV Line in the Perseus Galaxy Cluster

    NASA Astrophysics Data System (ADS)

    Aharonian, F. A.; Akamatsu, H.; Akimoto, F.; Allen, S. W.; Angelini, L.; Arnaud, K. A.; Audard, M.; Awaki, H.; Axelsson, M.; Bamba, A.; Bautz, M. W.; Blandford, R. D.; Bulbul, E.; Brenneman, L. W.; Brown, G. V.; Cackett, E. M.; Chernyakova, M.; Chiao, M. P.; Coppi, P.; Costantini, E.; de Plaa, J.; den Herder, J.-W.; Done, C.; Dotani, T.; Ebisawa, K.; Eckart, M. E.; Enoto, T.; Ezoe, Y.; Fabian, A. C.; Ferrigno, C.; Foster, A. R.; Fujimoto, R.; Fukazawa, Y.; Furuzawa, A.; Galeazzi, M.; Gallo, L. C.; Gandhi, P.; Giustini, M.; Goldwurm, A.; Gu, L.; Guainazzi, M.; Haba, Y.; Hagino, K.; Hamaguchi, K.; Harrus, I.; Hatsukade, I.; Hayashi, K.; Hayashi, T.; Hayashida, K.; Hiraga, J.; Hornschemeier, A. E.; Hoshino, A.; Hughes, J. P.; Ichinohe, Y.; Iizuka, R.; Inoue, H.; Inoue, S.; Inoue, Y.; Ishibashi, K.; Ishida, M.; Ishikawa, K.; Ishisaki, Y.; Itoh, M.; Iwai, M.; Iyomoto, N.; Kaastra, J. S.; Kallman, T.; Kamae, T.; Kara, E.; Kataoka, J.; Katsuda, S.; Katsuta, J.; Kawaharada, M.; Kawai, N.; Kelley, R. L.; Khangulyan, D.; Kilbourne, C. A.; King, A. L.; Kitaguchi, T.; Kitamoto, S.; Kitayama, T.; Kohmura, T.; Kokubun, M.; Koyama, S.; Koyama, K.; Kretschmar, P.; Krimm, H. A.; Kubota, A.; Kunieda, H.; Laurent, P.; Lebrun, F.; Lee, S.-H.; Leutenegger, M. A.; Limousin, O.; Loewenstein, M.; Long, K. S.; Lumb, D. H.; Madejski, G. M.; Maeda, Y.; Maier, D.; Makishima, K.; Markevitch, M.; Matsumoto, H.; Matsushita, K.; McCammon, D.; McNamara, B. R.; Mehdipour, M.; Miller, E. D.; Miller, J. M.; Mineshige, S.; Mitsuda, K.; Mitsuishi, I.; Miyazawa, T.; Mizuno, T.; Mori, H.; Mori, K.; Moseley, H.; Mukai, K.; Murakami, H.; Murakami, T.; Mushotzky, R. F.; Nakagawa, T.; Nakajima, H.; Nakamori, T.; Nakano, T.; Nakashima, S.; Nakazawa, K.; Nobukawa, K.; Nobukawa, M.; Noda, H.; Nomachi, M.; O’ Dell, S. L.; Odaka, H.; Ohashi, T.; Ohno, M.; Okajima, T.; Ota, N.; Ozaki, M.; Paerels, F.; Paltani, S.; Parmar, A.; Petre, R.; Pinto, C.; Pohl, M.; Porter, F. S.; Pottschmidt, K.; Ramsey, B. D.; Reynolds, C. S.; Russell, H. R.; Safi-Harb, S.; Saito, S.; Sakai, K.; Sameshima, H.; Sasaki, T.; Sato, G.; Sato, K.; Sato, R.; Sawada, M.; Schartel, N.; Serlemitsos, P. J.; Seta, H.; Shidatsu, M.; Simionescu, A.; Smith, R. K.; Soong, Y.; Stawarz, Ł.; Sugawara, Y.; Sugita, S.; Szymkowiak, A. E.; Tajima, H.; Takahashi, H.; Takahashi, T.; Takeda, S.; Takei, Y.; Tamagawa, T.; Tamura, K.; Tamura, T.; Tanaka, T.; Tanaka, Yasuo; Tanaka, Yasuyuki; Tashiro, M.; Tawara, Y.; Terada, Y.; Terashima, Y.; Tombesi, F.; Tomida, H.; Tsuboi, Y.; Tsujimoto, M.; Tsunemi, H.; Tsuru, T.; Uchida, H.; Uchiyama, H.; Uchiyama, Y.; Ueda, S.; Ueda, Y.; Ueno, S.; Uno, S.; Urry, C. M.; Ursino, E.; de Vries, C. P.; Watanabe, S.; Werner, N.; Wik, D. R.; Wilkins, D. R.; Williams, B. J.; Yamada, S.; Yamaguchi, H.; Yamaoka, K.; Yamasaki, N. Y.; Yamauchi, M.; Yamauchi, S.; Yaqoob, T.; Yatsu, Y.; Yonetoku, D.; Yoshida, A.; Zhuravleva, I.; Zoghbi, A.; Hitomi Collaboration

    2017-03-01

    High-resolution X-ray spectroscopy with Hitomi was expected to resolve the origin of the faint unidentified E≈ 3.5 {keV} emission line reported in several low-resolution studies of various massive systems, such as galaxies and clusters, including the Perseus cluster. We have analyzed the Hitomi first-light observation of the Perseus cluster. The emission line expected for Perseus based on the XMM-Newton signal from the large cluster sample under the dark matter decay scenario is too faint to be detectable in the Hitomi data. However, the previously reported 3.5 keV flux from Perseus was anomalously high compared to the sample-based prediction. We find no unidentified line at the reported high flux level. Taking into account the XMM measurement uncertainties for this region, the inconsistency with Hitomi is at a 99% significance for a broad dark matter line and at 99.7% for a narrow line from the gas. We do not find anomalously high fluxes of the nearby faint K line or the Ar satellite line that were proposed as explanations for the earlier 3.5 keV detections. We do find a hint of a broad excess near the energies of high-n transitions of S xvi (E≃ 3.44 {keV} rest-frame)—a possible signature of charge exchange in the molecular nebula and another proposed explanation for the unidentified line. While its energy is consistent with XMM pn detections, it is unlikely to explain the MOS signal. A confirmation of this interesting feature has to wait for a more sensitive observation with a future calorimeter experiment.

  17. The 511 keV emission from positron annihilation in the Galaxy

    SciTech Connect

    Prantzos, N.; Boehm, C.; Bykov, A. M.; Diehl, R.; Ferriere, K.; Guessoum, N.; Jean, P.; Knoedlseder, J.; Marcowith, A.; Moskalenko, I. V.; Strong, A.; Weidenspointner, G.

    2011-07-01

    The first {gamma}-ray line originating from outside the Solar System that was ever detected is the 511 keV emission from positron annihilation in the Galaxy. Despite 30 years of intense theoretical and observational investigation, the main sources of positrons have not been identified up to now. Observations in the 1990s with OSSE/CGRO (Oriented Scintillation Spectrometer Experiment on GRO satellite/Compton Gamma Ray Observatory) showed that the emission is strongly concentrated toward the Galactic bulge. In the 2000s, the spectrometer SPI aboard the European Space Agency's (ESA) International Gamma Ray Astrophysics Laboratory (INTEGRAL) allowed scientists to measure that emission across the entire Galaxy, revealing that the bulge-to-disk luminosity ratio is larger than observed at any other wavelength. This mapping prompted a number of novel explanations, including rather ''exotic'' ones (e.g., dark matter annihilation). However, conventional astrophysical sources, such as type Ia supernovae, microquasars, or x-ray binaries, are still plausible candidates for a large fraction of the observed total 511 keV emission of the bulge. A closer study of the subject reveals new layers of complexity, since positrons may propagate far away from their production sites, making it difficult to infer the underlying source distribution from the observed map of 511 keV emission. However, in contrast to the rather well-understood propagation of high-energy (>GeV) particles of Galactic cosmic rays, understanding the propagation of low-energy ({approx}MeV) positrons in the turbulent, magnetized interstellar medium still remains a formidable challenge. The spectral and imaging properties of the observed 511 keV emission are reviewed and candidate positron sources and models of positron propagation in the Galaxy are critically discussed.

  18. Grazing incidence diffraction of keV helium atoms on a Ag(110) surface.

    PubMed

    Bundaleski, N; Khemliche, H; Soulisse, P; Roncin, P

    2008-10-24

    Diffraction of fast atoms at grazing incidence has been recently demonstrated on the surface of alkali halides and wide band gap semiconductors, opening applications for the online monitoring of surface processes such as growth of ultrathin layers. This Letter reports energy resolved diffraction of helium on Ag(110) metal surface showing that a band gap is not mandatory to restrict the decoherence due to electron-hole pair excitations by the keV projectile. Measurement of the energy loss, which is in the eV range, sheds light on the scattering process.

  19. Simultaneous ejection of two molecular ions from keV gold atomic and polyatomic projectile impacts.

    PubMed

    Rickman, R D; Verkhoturov, S V; Parilis, E S; Schweikert, E A

    2004-01-30

    We present the first experimental data on the simultaneous ejection of two molecular ions from the impact of Au(+)(n) (1< or =n< or =4) with energies ranging between 17 and 56 keV. The yields from single phenylalanine (Ph) emission, coemission of two Ph ions, and emission of the Ph dimer were measured. Large increases (1 to 2 orders of magnitude) in coemitted ion yields were observed with increasing projectile energy and complexity. Correlation coefficients were calculated for the coemission of two Ph ions; their behavior suggests differences in emission pathways for bombardment by atomic and polyatomic projectiles.

  20. Investigations into the origin of the spurious 17 keV neutrino signal observed in35S beta decay

    NASA Astrophysics Data System (ADS)

    Bowler, M. G.; Jelley, N. A.

    1995-09-01

    An exhaustive study has been made of the β spectrum of35S, recorded with a Si(Li) detector. The object was to identify the origin of a distortion in the35S β spectrum some 17 keV below the end point, reported over three years ago and interpreted then as evidence for a 17 keV neutrino. Measurements with different source-detector spacings and with varied collimation have shown that there is a long range curvature in the Kurie plot which is a sensitive function of configuration, but the principal origin of the distortion is energy loss in the35S sources. The35S sources, prepared by chemical adsorption of Ba35SO4 on a gold substrate, are clumped and locally thick. Electrons near the end point lose ˜0.3 keV in the source material and if this is taken into account the spectra are well fitted without any admixture of 17 keV neutrino. The source thickness has been investigated with a proton microprobe and determined from both source tilting and the yield of barium K X-rays; these studies are discussed in detail. The uncertainties in and justification for the form of the electron response function employed are also thoroughly discussed. If there is no systematic error common to the majority of 14 independent sets of35S data, the admixture of 17 keV neutrino is <10-3 (95% CL). A simple search for a kink at 150 keV in the combined data from all 14 runs yielded a limit of 1.8×10-3 (95% CL). The end point of the35S β spectrum is found to be 167.60±0.05 keV.

  1. The Hard X-ray 20-40 keV AGN Luminosity Function

    NASA Technical Reports Server (NTRS)

    Beckmann, V.; Soldi, S.; Shrader, C. R.; Gehrels, N.; Produit, N.

    2006-01-01

    We have compiled a complete, significance limited extragalactic sample based on approximately 25,000 deg(sup 2) to a limiting flux of 3 x 10(exp -11) ergs per square centimeter per second. (approximately 7,000 deg(sup 2)) to a flux limit of 10(exp -11) ergs per square centimeter per second)) in the 20 - 40 keV band with INTEGRAL. We have constructed a detailed exposure map to compensate for effects of non-uniform exposure. The flux-number relation is best described by a power-law with a slope of alpha = 1.66 plus or minus 0.11. The integration of the cumulative flux per unit area leads to f(sub 20-40 keV) = 2.6 x 10(exp -10) ergs per square centimeter per second per sr(sup -1) which is about 1% of the known 20-40 keV X-ray background. We present the first luminosity function of AGN in the 20-40 keV energy range, based on 68 extragalactic objects detected by the imager IBIS/ISGRI on-board INTEGRAL. The luminosity function shows a smoothly connected two power-law form, with an index of gamma (sub 1) = 0.9 below, and gamma (sub 2) = 2.2 above the turn-over luminosity of L(sub *), = 4.6 x 10(sup 43) ergs per second. The emissivity of all INTEGRAL AGNs per unit volume is W(sub 20-40keV)(greater than 10(sup 41) ergs per second) = 2.8 x 10(sup 38) ergs per second h(sup 3)(sub 70) Mpc(sup -3). These results are consistent with those derived in the 2-20keV energy band and do not show a significant contribution by Compton-thick objects. Because the sample used in this study is truly local (z(raised bar) = 0.022)), only limited conclusions can be drawn for the evolution of AGNs in this energy band. But the objects explaining the peak in the cosmic X-ray background are likely to be either low luminosity AGN (L(sub x) less than 10(sup 41) ergs per second) or of other type, such as intermediate mass black holes, clusters, and star forming regions.

  2. KevJumba and the Adolescence of YouTube

    ERIC Educational Resources Information Center

    Saul, Roger

    2010-01-01

    This article considers the significance of YouTube as a pedagogical space from which young people can play participatory roles as theorists in their own constructions as popular cultural subjects. Drawing upon the public profile of "KevJumba," a teenager who makes videos of himself on YouTube, the article suggests that representational practices…

  3. Testing the Axion-Conversion Hypothesis of 3.5 keV Emission with Polarization

    NASA Astrophysics Data System (ADS)

    Gong, Yan; Chen, Xuelei; Feng, Hua

    2017-02-01

    The recently measured 3.5 keV line in a number of galaxy clusters, the Andromeda galaxy (M31), and the Milky Way (MW) center can be well accounted for by a scenario in which dark matter decays to axionlike particles (ALPs) and subsequently convert to 3.5 keV photons in magnetic fields of galaxy clusters or galaxies. We propose to test this hypothesis by performing x-ray polarization measurements. Since ALPs can only couple to photons with a polarization orientation parallel to the magnetic field, we can confirm or reject this model by measuring the polarization of the 3.5 keV line and compare it to the orientation of the magnetic field. We discuss luminosity and polarization measurements for both a galaxy cluster and spiral galaxy, and provide a general relation between the polarization and galaxy inclination angle. This effect is marginally detectable with x-ray polarimetry detectors currently under development, such as the enhanced X-ray Timing and Polarization satellite, the Imaging X-ray Polarimetry Explorer and the X-ray Imaging Polarimetry Explorer. The sensitivity can be further improved in the future with detectors of a larger effective area or better energy resolutions.

  4. A study of 2-20 KeV X-rays from the Cygnus region

    NASA Technical Reports Server (NTRS)

    Bleach, R. D.

    1972-01-01

    Two rocket-borne proportional counters, each with 650 sq c, met area and 1.8 x 7.1 deg FWHM rectangular mechanical collimation, surveyed the Cygnus region in the 2 to 20 keV energy range on two occasions. X-ray spectral data gathered on 21 September 1970 from discrete sources in Cygnus are presented. The data from Cyg X-1, Cyg X-2, and Cyg X-3 have sufficient statistical significance to indicate mutually exclusive spectral forms for the three. Upper limits are presented for X-ray intensities above 2 keV for Cyg X-4 and Cyg X-5 (Cygnus loop). A search was made on 9 August 1971 for a diffuse component of X-rays 1.5 keV associated with an interarm region of the galaxy at galactic longitudes in the vicinity of 60 degrees. A statistically significant excess associated with a narrow disk component was detected. Several possible emission models are discussed, with the most likely candidate being a population of unresolvable low luminosity discrete sources.

  5. Demonstration of a 13-keV Kr K-shell x-ray source at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Fournier, K. B.; May, M. J.; Colvin, J. D.; Barrios, M. A.; Patterson, J. R.; Regan, S. P.

    2013-09-01

    We report 3% conversion efficiency of laser energy into Kr K-shell (≈13 keV) radiation, consistent with theoretical predictions. This is ≈10× greater than previous work. The emission was produced from a 4.1-mm-diameter, 4-mm-tall gas pipe target filled with 1.2 or 1.5 atm of Kr gas. 160 of the National Ignition Facility laser beams deposited ≈700 kJ of 3ω light into the target in an ≈140 TW, 5.0-ns-duration square pulse. The Dante diagnostics measured ≈5 TW into 4π solid angle of ≥12 keV x rays for ≈4 ns, which includes both continuum emission and flux in the Kr Heα line at 13 keV.

  6. OSSE observations of galactic 511 keV annihilation radiation

    NASA Technical Reports Server (NTRS)

    Purcell, W. R.; Grabelsky, D. A.; Johnson, W. N.; Jung, G. V.; Kinzer, R. L.; Kurfess, J. D.; Strickman, M. S.; Ulmer, M. P.

    1992-01-01

    The Oriented Scintillation Spectrometer Experiment (OSSE) on the Compton Gamma-Ray Observatory has performed several observations of the galactic plane and galactic center region to measure the distribution of galactic 511 keV positron annihilation radiation. Preliminary analysis of data collected during the observation of the galactic center region over the period 13-24 Jun. 1991, indicates the presence of a 511 keV line and positronium continuum superimposed on a power-law continuum. The line of flux was found to be (2.7 +/- 0.5) x 10(exp -4) gamma/sq cm sec, with a positronium fraction of (0.9 +/- 0.2). The 3(sigma) upper limit to daily variations in the 511 keV line flux from the mean during the observation interval is 3 x 10(exp -4) gamma/sq cm sec. If all of the observed annihilation radiation is assumed to originate from the x-ray source 1E 1740.7-2942, the corresponding 511 keV line flux would be (3.0 +/- 0.6) x 10(exp -4) gamma/sq cm sec. The 3(sigma) upper limit for 511 keV line emission from the x-ray binary GX1+4 is 6 x 10(exp -4) gamma/sq cm sec. Results from the galactic plane observations at galactic longitudes of 25 degrees (16-21 Aug. 1991) and 339 degrees (6-11 Sep. 1991) suggest that the emission is concentrated near the galactic center. The observations and the preliminary results are described.

  7. Relative detection efficiency of back- and front-illuminated charge-coupled device cameras for X-rays between 1 keV and 18 keV.

    PubMed

    Szlachetko, J; Dousse, J-Cl; Hoszowska, J; Berset, M; Cao, W; Szlachetko, M; Kavcic, M

    2007-09-01

    High-resolution x-ray measurements were performed with a von Hamos-type bent crystal spectrometer using for the detection of the diffracted photons either a back-illuminated charge-coupled device (CCD) camera or a front-illuminated one. For each CCD the main x-ray emission lines (e.g., Kalpha, Kbeta, Lalpha, and Lbeta) of a variety of elements were measured in order to probe the performances of the two detectors between 1 and 18 keV. From the observed x-ray lines the linearity of the energy response, the noise level, the energy resolution, and the quantum efficiency ratio of the two CCDs were determined.

  8. Enhancement of Spatial Thinking with Virtual Spaces 1.0

    ERIC Educational Resources Information Center

    Hauptman, Hanoch

    2010-01-01

    Developing a software environment to enhance 3D geometric proficiency demands the consideration of theoretical views of the learning process. Simultaneously, this effort requires taking into account the range of tools that technology offers, as well as their limitations. In this paper, we report on the design of Virtual Spaces 1.0 software, a…

  9. IDC Use Case Model Survey Version 1.0.

    SciTech Connect

    Carr, Dorthe B.; Harris, James M.

    2014-12-01

    This document contains the brief descriptions for the actors and use cases contained in the IDC Use Case Model Survey. REVISIONS Version Date Author/Team Revision Description Authorized by V1.0 12/2014 IDC Re- engineering Project Team Initial delivery M. Harris

  10. Scout 2008 Version 1.0 User Guide

    EPA Science Inventory

    The Scout 2008 version 1.0 software package provides a wide variety of classical and robust statistical methods that are not typically available in other commercial software packages. A major part of Scout deals with classical, robust, and resistant univariate and multivariate ou...

  11. Quick Overview Scout 2008 Version 1.0

    EPA Science Inventory

    The Scout 2008 version 1.0 statistical software package has been updated from past DOS and Windows versions to provide classical and robust univariate and multivariate graphical and statistical methods that are not typically available in commercial or freeware statistical softwar...

  12. MULTIPLE PROJECTIONS SYSTEM (MPS) - USER'S MANUAL VERSION 1.0

    EPA Science Inventory

    The report is a user's manual for version 1.0 of the Multiple Projections Systems (MPS), a computer system that can perform "what if" scenario analysis and report the final results (i.e., Rate of Further Progress - ROP - inventories) to EPA (i.e., the Aerometric Information Retri...

  13. Neutron transmission and capture measurements and analysis of /sup 60/Ni from 1 to 450 keV

    SciTech Connect

    Perey, C.M.; Harvey, J.A.; Macklin, R.L.; Winters, R.R.; Perey, F.G.

    1982-11-01

    High-resolution transmission and capture measurements of /sup 60/Ni-enriched targets have been made at the Oak Ridge Electron Linear Accelerator (ORELA) from a few eV to 1800 keV in transmission and from 2.5 keV to 5 MeV in capture . The transmission data from 1 to 450 keV were analyzed with a multi-level R-matrix code which uses the Bayes' theorem for the fitting process. This code provides the energies and neutron widths of the resonances inside the 1- to 450-keV region as well as a possible parameterization for outside resonances to describe the smooth cross section in this region. The capture data were analyzed with a least-squares fitting code using the Breit-Wigner formula. From 2.5 to 450 keV, 166 resonances were seen in both sets of data. Correspondence between the energy scales shows a discontinuity around 300 keV which makes the matching of resonances at higher energies difficult. Eighty-nine resonances were seen in the capture data only. Average parameters for the 30 observed s-wave resonances were deduced. The average level spacing D/sub 0/ was found to be equal to 15.2 +- 1.5 keV, the strength function, S/sub 0/, equal to (2.2 +- 0.6) x 10/sup -4/ and the average radiation width, GAMMA/sub ..gamma../, equal to 1.30 +- 0.07 eV. The staircase plot of the reduced level widths and the plot of the Lorentz-weighted strength function averaged over various energy intervals show possible evidence for doorway states. The level densities calculated with the Fermi-gas model for l = 0 and for l > 0 resonances were compared with the cumulative number of observed resonances, but the analysis is not conclusive. The average capture cross section as a function of the neutron incident energy is compared to the tail of the giant electric dipole resonance prediction.

  14. Charge transfer and excitation in H++CH3 collisions below 10keV

    NASA Astrophysics Data System (ADS)

    Nagao, Masatoshi; Hida, Ken-Nosuke; Kimura, Mineo; Rai, Sachchida N.; Liebermann, Heinz-Peter; Buenker, Robert J.; Suno, Hiroya; Stancil, Phillip C.

    2008-07-01

    Charge transfer and electronic excitation in collisions of H+ ions with CH3 from a few tens of eV up to 10keV are theoretically investigated. The adiabatic potential energy curves and corresponding wave functions are calculated by using the multireference single- and double-excitation configuration interaction method, and the scattering dynamics is studied based on the semiclassical impact parameter molecular-orbital close-coupling approach. Charge-transfer cross sections are found to be large and rather energy-dependent over the entire energy region studied. Electronic excitation is also energy-dependent with a sharp increase from below 10-17to10-16cm2 . Most of the molecular products produced through charge transfer or excitation are known to be unstable and undergo fragmentation producing various hydrocarbon radical species. Hence, identification of fragmented species and their production mechanism are important for spectroscopic analysis.

  15. Effect of 800 keV argon ions pre-damage on the helium blister formation of tungsten exposed to 60 keV helium ions

    NASA Astrophysics Data System (ADS)

    Chen, Zhe; Han, Wenjia; Yu, Jiangang; Zhu, Kaigui

    2016-04-01

    This study aims to investigate the effect of Ar8+ ions pre-damage on the following He2+ irradiation behavior of polycrystalline tungsten. We compared the irradiation resistance performance against 60 keV He2+ ions of undamaged tungsten samples with that of pre-damaged samples which were preliminarily exposed to 800 keV Ar8+ ions at a fluence of 4 × 1019 ions m-2. The experimental results indicate that the helium blistering of tungsten could be effectively relieved by the Ar8+ ions pre-damage, while the retention of helium around low energy desorption sites in the pre-damaged tungsten was larger than that of the undamaged samples. A strong orientation dependence of blistering had been observed, with the blister occurred preferentially on the surface of grains with normal direction close to <111>. The Ar8+ ions irradiation-induced damage altered the morphology of helium bubbles in tungsten exposed to the following He2+ irradiation significantly. The intensity of helium release peaks at relatively low temperatures (<600 K) was enhanced due to Ar8+ ions pre-damage.

  16. Sterilization of foods with low-energy electrons (``soft-electrons'')

    NASA Astrophysics Data System (ADS)

    Hayashi, Toru; Takahashi, Yoko; Todoriki, Setsuko

    1998-06-01

    Electrons with an energy of 300 keV or lower were defined as "Soft-electrons", which showed several advantages over conventional irradiation with gamma-rays or high-energy electrons in decontamination of grains and spices. Energies of electrons necessary to reduce microbial loads to levels lower than 10 CFU/g were 60 keV for brown rice, 75 keV for wheat, 100 keV for white pepper, coriander and basil, 130 keV for buckwheat, 160 keV for rough rice, and 210 keV for black pepper. Electrons with such energies did not significantly influence the quality.

  17. Asymmetric 511 keV Positron Annihilation Line Emission from the Inner Galactic Disk

    NASA Technical Reports Server (NTRS)

    Skinner, Gerry; Weidenspointner, Georg; Jean, Pierre; Knodlseder, Jurgen; Ballmoos, Perer von; Bignami, Giovanni; Diehl, Roland; Strong, Andrew; Cordier, Bertrand; Schanne, Stephane; Winkler, Christoph

    2008-01-01

    A recently reported asymmetry in the 511 keV gamma-ray line emission from the inner galactic disk is unexpected and mimics an equally unexpected one in the distribution of LMXBs seen at hard X-ray energies. A possible conclusion is that LMXBs are an important source of the positrons whose annihilation gives rise to the line. We will discuss these results, their statistical significance and that of any link between the two. The implication of any association between LMXBs and positrons for the strong annihilation radiation from the galactic bulge will be reviewed.

  18. The effect of 1 to 5 keV electrons on the reproductive integrity of microorganisms

    NASA Technical Reports Server (NTRS)

    Barengoltz, J. B.; Brady, J.

    1977-01-01

    Microorganisms were exposed to simulated space environment in order to assess the effect of electrons in the energy range 1 to 5 keV on their colony-forming ability. The test system consisted of an electron gun and power supply, a dosimetry subsystem, and a vacuum subsystem. The system was capable of current densities ranging from 0.1 nA/sq cm to 5 micro A/sq cm on a 25 sq on target and an ultimate vacuum of 0.0006 N/sq m (0.000004 torr). The results of the experimental program show a significant reduction in microbial reproductive integrity.

  19. Ionization and Fragmentation of 5-Chlorouracil induced by 100 keV protons collisions

    SciTech Connect

    Cafarelli, Pierre; Champeaux, Jean-Philippe; Le Padellec, Arnaud; Moretto-Capelle, Patrick; Rabier, Julien; Sence, Martine; Carcabal, Pierre

    2008-12-08

    We present preliminary experimental results on the dissociation of singly and doubly ionized 5-Chlorouracil induced by collisions with proton of 100 keV energy. Multiple coincidence techniques are used to detect the ionic fragments from single dissociation events. This enables a thorough analysis of kinetic momentums of the charged and neutral species involved in the dissociation. In many cases, this leads to the establishment of the scenario the molecule undergoes after ionization as well as the determination of the nature of intermediate (undetected) species. In other cases, the dissociation scenario cannot be unambiguously identified and further analysis as well as theoretical support is needed.

  20. Spectroscopy from 2 to 200 keV

    NASA Technical Reports Server (NTRS)

    Helfand, D. J.; Chanan, G. A.; Novick, R.; Maccallum, C. J.; Leventhal, M.

    1981-01-01

    The astrophysical processes responsible for line and continuum emission in the spectra range 2 keV to 200 keV are examined from the viewpoint of designing a spectrometer which would operate in this regime. Phenomena considered include fluorescent line radiation in X-ray binaries, magnetically shifted iron lines and cyclotron emission from neutron star surfaces, line emission from cosmically abundant elements in thermal plasmas, and nuclear deexcitation lines in fresh nucleosynthetically produced matter. An instrument consisting of a approximately 10 sq cm array of planar germanium detectors surrounded by a large sodium-iodide anticoincidence shield is described and projected background rates and sensitivities are considered. A sample observing program for a two-day shuttle-based mission is included as an example of the wide range of scientific questions which could be addressed by such an instrument.

  1. ART: Surveying the Local Universe at 2-11 keV

    NASA Astrophysics Data System (ADS)

    O'Dell, Stephen L.; Ramsey, B. D.; Adams, M. L.; Areviev, V.; Brandt, W. N.; Buntov, M.; Elsner, R. F.; Grigorovich, S.; Gubarev, M. V.; Hasinger, G.; Lapshov, I.; Litvin, D.; Meidinger, N.; Pavlinsky, M.; Predehl, P.; Revnivtsev, M.; Romaine, S. E.; Sazonov, S.; Semena, N.; Swartz, D. A.; Tkachenko, A.; Urry, C. M.; Vikhlinin, A.; Weisskopf, M. C.

    2008-03-01

    The Astronomical Röntgen Telescope (ART) is a medium-energy x-ray telescope system proposed for the Russian-led mission Spectrum Röntgen-Gamma (SRG). Optimized for performance over the 2-11-keV band, ART complements the softer response of the SRG prime instrument - the German eROSITA x-ray telescope system. The anticipated number of ART detections is 50,000 - with about 1,000 heavily-obscured (NH > 3×1023 cm-2) active galactic nuclei (AGN) - in the SRG 4-year all-sky survey, plus a comparable number in deeper wide-field (500 deg2 total) surveys. ART's surveys will provide a minimally-biased, nearly-complete census of the local Universe in the medium-energy x-ray band (including Fe-K lines), at CCD spectral resolution. During long (�-ks) pointed observations, ART can obtain statistically significant spectral data up to about 15 keV for bright sources and medium-energy x-ray continuum and Fe-K-line spectra of AGN detected with the contemporaneous NuSTAR hard-x-ray mission.

  2. Energy levels of {sup 251}Cf populated in the {alpha} decay of {sub 100}{sup 255}Fm and EC decay of {sub 99}{sup 251}Es

    SciTech Connect

    Ahmad, I.; Greene, J.P.; Moore, E.F.; Kondev, F.G.; Chasman, R.R.; Porter, C.E.; Felker, L.K.

    2005-11-01

    Gamma-ray singles spectra of extremely pure (chemically and isotopically) samples of {sup 255}Fm, with strengths of {approx}1 mCi, have been measured with a high-resolution 2-cm{sup 2}x10-mm germanium LEPS detector and with a 25% Ge spectrometer. Gamma rays with intensities as low as 1.0x10{sup -6}% per {sup 255}Fm {alpha} decay have been identified. The electron spectrum of a mass-separated {sup 251}Es source was measured with a cooled Si(Li) electron spectrometer. The spectrum provided the conversion coefficients of low-energy transitions in {sup 251}Cf and thereby their multipolarities. The present measurements confirm the previous assignments of single-particle states in {sup 251}Cf. These include 1/2{sup +}[620], 0.0 keV; 7/2{sup +}[613], 106.30 keV; 3/2{sup +}[622], 177.59 keV; 11/2{sup -}[725], 370.47 keV; 9/2{sup -}[734], 433.91 keV; 5/2{sup +}[622], 543.98 keV; 1/2{sup -}[750], 632.0 keV; 9/2{sup +}[615], 683 keV; and 9/2{sup +}[604], 974.0 keV. A vibrational band was identified in previous studies at 981.4 keV and given an assignment of {l_brace}7/2{sup +}[613]x2{sup -}{r_brace}3/2{sup -}. Three new vibrational bands are identified in the present work at 942.5, 1086.5, and 1250.0 keV with tentative assignments {l_brace}7/2{sup +}[613]x1{sup -}{r_brace}5/2{sup -},{l_brace}7/2{sup +}[613]x1{sup -}{r_brace}9/2{sup -}, and {l_brace}7/2{sup +}[613]x0{sup +}{r_brace}7/2{sup +}, respectively. A level was identified at 1185.5 keV with spin of 5/2 or 7/2 but it was not given any configuration assignment. Another level was identified at 1077.5 keV and given a spin of 9/2. Again, no configuration could be assigned to this level.

  3. Optimal Jet Finder (v1.0 C++)

    NASA Astrophysics Data System (ADS)

    Chumakov, S.; Jankowski, E.; Tkachov, F. V.

    2006-10-01

    We describe a C++ implementation of the Optimal Jet Definition for identification of jets in hadronic final states of particle collisions. We explain interface subroutines and provide a usage example. The source code is available from http://www.inr.ac.ru/~ftkachov/projects/jets/. Program summaryTitle of program: Optimal Jet Finder (v1.0 C++) Catalogue identifier: ADSB_v2_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/ADSB_v2_0 Program obtainable from: CPC Program Library, Queen's University of Belfast, N. Ireland Computer: any computer with a standard C++ compiler Tested with:GNU gcc 3.4.2, Linux Fedora Core 3, Intel i686; Forte Developer 7 C++ 5.4, SunOS 5.9, UltraSPARC III+; Microsoft Visual C++ Toolkit 2003 (compiler 13.10.3077, linker 7.10.30777, option /EHsc), Windows XP, Intel i686. Programming language used: C++ Memory required:˜1 MB (or more, depending on the settings) No. of lines in distributed program, including test data, etc.: 3047 No. of bytes in distributed program, including test data, etc.: 17 884 Distribution format: tar.gz Nature of physical problem: Analysis of hadronic final states in high energy particle collision experiments often involves identification of hadronic jets. A large number of hadrons detected in the calorimeter is reduced to a few jets by means of a jet finding algorithm. The jets are used in further analysis which would be difficult or impossible when applied directly to the hadrons. Grigoriev et al. [D.Yu. Grigoriev, E. Jankowski, F.V. Tkachov, Phys. Rev. Lett. 91 (2003) 061801] provide brief introduction to the subject of jet finding algorithms and a general review of the physics of jets can be found in [R. Barlow, Rep. Prog. Phys. 36 (1993) 1067]. Method of solution: The software we provide is an implementation of the so-called Optimal Jet Definition (OJD). The theory of OJD was developed in [F.V. Tkachov, Phys. Rev. Lett. 73 (1994) 2405; Erratum, Phys. Rev. Lett. 74 (1995) 2618; F.V. Tkachov, Int. J. Modern Phys

  4. Visual Sample Plan Version 1.0 User's Guide

    SciTech Connect

    Davidson, James R.; Hassig, Nancy L.; Wilson, John E.; Gilbert, Richard O.

    2001-04-13

    This user's guide describes Visual Sample Plan (VSP) Version 1.0 and provides instructions for using the software. VSP selects the appropriate number and location of environmental samples to ensure that the results of statistical tests performed to provide input to environmental decisions have the required confidence and performance. VSP Version 1.0 provides sample-size equations or algorithms needed by specific statistical tests appropriate for specific environmental sampling objectives. The easy-to-use program is highly visual and graphic. VSP runs on personal computers with Microsoft Windows operating systems (95, 98, Millenium Edition, 2000, and Windows NT). Designed primarily for project managers and users without expertise in statistics, VSP is applicable to any two-dimensional geographical population to be sampled (e.g., surface soil, a defined layer of subsurface soil, building surfaces, water bodies, and other similar applications) for studies of environmental quality.

  5. The Context for IMAP: Voyager and INCA Observations of the Heliosheath at E > 5 keV

    NASA Astrophysics Data System (ADS)

    Krimigis, Stamatios M.

    2016-04-01

    The basic premise of the proposed Interstellar Mapping and Acceleration Probe (IMAP) is detailed scientific understanding of the Heliosheath (HS) and beyond, a region of space explored in situ by Voyager 1 (V1) since 2004, Voyager 2 (V2) since 2007, and remotely via energetic neutral atoms (ENA) by the Cassini/INCA (Ion and Neutral CAmera) since 2003 and IBEX since 2009. The IMAP instrumentation proposed for this purpose combines and extends the IBEX and INCA ENA energy ranges (0.3- 20 keV and 3-200 keV, for low and high energy, respectively). All three missions-Voyagers, Cassini/INCA, and IBEX- have made discovery-class measurements in the HS, the Voyagers providing in situ ion intensities at E > 30 keV, while INCA images ENA in the range 5 < E < 55 keV, and IBEX 0.3 < E < 6 keV. The partial overlap in energy coverage between Voyager ions and INCA ENA allows for the possibility of observing the intensity and time evolution of ions in the HS, thought to give rise to the ENAs via charge-exchange, and the resultant ENA images in the inner heliosphere and their spatial and/or temporal variability. Unfortunately, no such "ground truth" ion measurements are possible at Voyager in the ENA energy range imaged by IBEX. Some of the key findings from the Voyager and Cassini/INCA measurements are as follows: (1) The HS contains a hot plasma population that carries a substantial part (30-50 %) of the total pressure at E > 5 keV, the rest residing below that range, resulting in a beta (particle/magnetic pressure) always > 1, typically >10. (2) The width of the HS in the direction of V1 is ~ 30 AU, but is thought to be larger (40-70 AU) in the southern ecliptic where V2 currently travels.. (3) The ENA intensities at E > 5 keV exhibit a correlation with the solar cycle (SC) over the period 2003 to 2015, with minimum intensities in the anti-nose direction observed ~ 1.5 yrs after solar minimum followed by a recovery thereafter. (4) The in situ ion measurements at V2 within the HS

  6. Babel 1.0 Release Criteria: A Working Document

    SciTech Connect

    Kumfert, G; Dahlgren, T; Epperly, T; Leek, J

    2004-10-19

    In keeping with the Open Source tradition, we want our Babel 1.0 release to indicate a certain level of capability, maturity, and stability. From our first release (version 0.5.0) in July of 2001 to our current (18th) release (version 0.9.6) we have continued to add capabilities in response to customer feedback, our observations in the field, and a consistent vision for interoperability. The key to our maturity is without a doubt the ever-increasing demands of our growing user base... both in terms of sheer size and sophistication with the underlying technology. Stability is a special challenge for any research project. With our 1.0 release, we will branch and maintain a stable Babel 1.0 code line for at least a full year. This means no new features and no backward incompatible changes, only bug fixes. All continuing R&D will be performed on a separate development tree. Currently, Babel has a quarterly release cycle with no guarantee for backward compatibility from one release to the next (though we certainly try to make migration as painless as possible). Now is the time where we can see a good point for a Babel 1.0 release. But, seeing that point is different from being there. This list enumerates and explains the outstanding technical issues to be resolved to minimize volatility and help ensure stability for the 1.0 line. The first draft of this document was circulated internally in June 2003. A revised draft was then presented at the July 2003 CCA meeting. A third revision was made into the current working document form & circulated for general comment on the babel-users mailing list and Babel's homepage. The working document was intended to be an open record tracking progress in subsequent Babel releases. A major revision of the document (including adding new items and promoting/demoting items) was done in October 2004, well after the 0.9.6 release.

  7. Delta-doped CCD's as low-energy particle detectors and imagers

    NASA Technical Reports Server (NTRS)

    Nikzad, Shouleh (Inventor); Hoenk, Michael E. (Inventor); Hecht, Michael H. (Inventor)

    2002-01-01

    The back surface of a thinned charged-coupled device (CCD) is treated to eliminate the backside potential well that appears in a conventional thinned CCD during backside illumination. The backside of the CCD includes a delta layer of high-concentration dopant confined to less than one monolayer of the crystal semiconductor. The thinned, delta-doped CCD is used to detect very low-energy particles that penetrate less than 1.0 nm into the CCD, including electrons having energies less than 1000 eV and protons having energies less than 10 keV.

  8. Full characterization of a laser-produced keV x-ray betatron source

    NASA Astrophysics Data System (ADS)

    Albert, F.; Phuoc, K. Ta; Shah, R.; Corde, S.; Fitour, R.; Tafzi, A.; Burgy, F.; Douillet, D.; Lefrou, T.; Rousse, A.

    2008-12-01

    This paper presents the complete characterization of a kilo-electron-volt laser-based x-ray source. The main parameters of the electron motion (amplitude of oscillations and initial energy) in the laser wakefield have been investigated using three independent methods relying on spectral and spatial properties of this betatron x-ray source. First we will show studies on the spectral correlation between electrons and x-rays that is analyzed using a numerical code to calculate the expected photon spectra from the experimentally measured electron spectra. High-resolution x-ray spectrometers have been used to characterize the x-ray spectra within 0.8-3 keV and to show that the betatron oscillations lie within 1 µm. Then we observed Fresnel edge diffraction of the x-ray beam. The observed diffraction at the center energy of 4 keV agrees with the Gaussian incoherent source profile of full width half maximum <5 µm, meaning that the amplitude of the betatron oscillations is less than 2.5 µm. Finally, by measuring the far field spatial profile of the radiation, we have been able to characterize the electron's trajectories inside the plasma accelerator structure with a resolution better than 0.5 µm.

  9. Application of keV and MeV ion microbeams through tapered glass capillaries

    NASA Astrophysics Data System (ADS)

    Ikeda, T.; Kojima, T. M.; Kobayashi, T.; Meissl, W.; Mäckel, V.; Kanai, Y.; Yamazaki, Y.

    2012-11-01

    We have developed a method to produce micrometer-sized beams of keV energy highly charged ions (HCIs) and MeV energy protons/helium ions with tapered glass capillary optics for the applications of micrometer sized surface modifications and a biological tool, respectively. The transmission experiments of keV HCIs through the glass capillaries show a density enhancement of about 10, beam guiding up to 5°, and the extracted beam keeping the initial charge-state. The combination of MeV ion beams and the capillary with a thin end window at its outlet was used for the irradiation of a part of nucleus of a HeLa cell in culture solution. Escherichia coli cells are irradiated by MeV proton microbeam to determine the minimum dose to stop the single flagellar motor. Scanning irradiation of polymer surface by the beam extracted from the capillary in solution containing acrylic acid was found to provide a deposition layer with large affinity with water.

  10. A 7.2 keV spherical crystal backlighter system for Sandia's Z Pulsed Power Facility

    NASA Astrophysics Data System (ADS)

    Schollmeier, M.; Knapp, P. F.; Ampleford, D. J.; Loisel, G. P.; Robertson, G.; Shores, J. E.; Smith, I. C.; Speas, C. S.; Porter, J. L.; McBride, R. D.

    2016-10-01

    Many experiments on Sandia's Z facility, a 30 MA, 100 ns rise-time, pulsed-power driver, use a monochromatic Quartz crystal imaging backlighter system at 1.865 keV (Si Heα) or 6.151 keV (Mn Heα) x-ray energy to radiograph an imploding liner (cylindrical tube) or wire array. The x-ray source is generated by the Z-Beamlet Laser (ZBL), which provides up to 4.5 kJ at 527 nm during a 6 ns window. Radiographs of an imploding thick-walled Beryllium liner at a convergence ratio of about 20 [CR =Rin . (0) /Rin . (t) ] were too opaque to identify the inner surface of the liner with high confidence, demonstrating the need for a higher-energy x-ray backlighter between 6 and 10 keV. We present the design, test and first application of a Ge (335) spherical crystal x-ray backlighter system using the 7.242 keV Co Heα resonance line. The system operates at an almost identical Bragg angle as the existing 1.865 and 6.151 keV backlighters, enhancing our capabilities such as two-color, two-frame radiography, without changing detector shielding hardware. SAND No: SAND2016-6724 A. Sandia National Laboratories is a multi-program laboratory managed and operated by Sandia Corp., a wholly owned subsidiary of Lockheed Martin Corp., for the U.S. DoE NNSA under contract DE-AC04-94AL85000.

  11. SSEL1.0. Sandia Scalable Encryption Software

    SciTech Connect

    Tarman, T.D.

    1996-08-29

    Sandia Scalable Encryption Library (SSEL) Version 1.0 is a library of functions that implement Sandia`s scalable encryption algorithm. This algorithm is used to encrypt Asynchronous Transfer Mode (ATM) data traffic, and is capable of operating on an arbitrary number of bits at a time (which permits scaling via parallel implementations), while being interoperable with differently scaled versions of this algorithm. The routines in this library implement 8 bit and 32 bit versions of a non-linear mixer which is compatible with Sandia`s hardware-based ATM encryptor.

  12. Over 1.0 mm-long boron nitride nanotubes

    NASA Astrophysics Data System (ADS)

    Chen, Hua; Chen, Ying; Liu, Yun; Fu, Lan; Huang, Cheng; Llewellyn, David

    2008-09-01

    Over 1.0 mm boron nitride nanotubes (BNNTs) were successfully synthesized by an optimized ball milling and annealing method. The annealing temperature of 1100 °C is crucial for the growth of the long BNNTs because at this temperature there is a fast nitrogen dissolution rate in Fe and the B/N ratio in Fe is 1. Such long BNNTs enable a reliable single tube configuration for electrical property characterization and consequently the average resistivity of the long BNNTs is determined to be 7.1 ± 0.9 × 10 4 Ω cm. Therefore, these BNNTs are promising insulators for three dimensional microelectromechanical system.

  13. Decaying vector dark matter as an explanation for the 3.5 keV line from galaxy clusters

    SciTech Connect

    Farzan, Yasaman; Akbarieh, Amin Rezaei E-mail: am_rezaei@physics.sharif.ir

    2014-11-01

    We present a Vector Dark Matter (VDM) model that explains the 3.5 keV line recently observed in the XMM-Newton observatory data from galaxy clusters. In this model, dark matter is composed of two vector bosons, V and V', which couple to the photon through an effective generalized Chern-Simons coupling, g{sub V}. V' is slightly heavier than V with a mass splitting m{sub V'} – m{sub V} ≅ 3.5 keV. The decay of V' to V and a photon gives rise to the 3.5 keV line. The production of V and V' takes place in the early universe within the freeze-in framework through the effective g{sub V} coupling when m{sub V'} < T < Λ, Λ being the cut-off above which the effective g{sub V} coupling is not valid. We introduce a high energy model that gives rise to the g{sub V} coupling at low energies. To do this, V and V' are promoted to gauge bosons of spontaneously broken new U(1){sub V} and U(1){sub V'} gauge symmetries, respectively. The high energy sector includes milli-charged chiral fermions that lead to the g{sub V} coupling at low energy via triangle diagrams.

  14. 3.55 keV photon lines from axion to photon conversion in the Milky Way and M31

    SciTech Connect

    Conlon, Joseph P.; Day, Francesca V. E-mail: francesca.day@physics.ox.ac.uk

    2014-11-01

    We further explore a scenario in which the recently observed 3.55 keV photon line arises from dark matter decay to an axion-like particle (ALP) of energy 3.55 keV, which then converts to a photon in astrophysical magnetic fields. This ALP scenario is well-motivated by the observed morphology of the 3.55 keV flux. For this scenario we study the expected flux from dark matter decay in the galactic halos of both the Milky Way and Andromeda (M31). The Milky Way magnetic field is asymmetric about the galactic centre, and so the resulting 3.55 keV flux morphology differs significantly from the case of direct dark matter decay to photons. However the Milky Way magnetic field is not large enough to generate an observable signal, even with ASTRO-H. In contrast, M31 has optimal conditions for a → γ conversion and the intrinsic signal from M31 becomes two orders of magnitude larger than for the Milky Way, comparable to that from clusters and consistent with observations.

  15. A New Observation of the Quiet Sun Soft X-ray (0.5-5 keV) Spectrum

    NASA Astrophysics Data System (ADS)

    Caspi, A.; Woods, T. N.; Stone, J.

    2012-12-01

    The solar corona is the brightest source of X-rays in the solar system, and the X-ray emission is highly variable with solar activity. While this is particularly true during solar flares, when emission can be enhanced by many orders of magnitude up to gamma-ray energies, even the so-called "quiet Sun" is bright in soft X-rays (SXRs), as the ~1-2 MK ambient plasma of the corona emits significant thermal bremsstrahlung up to ~5 keV. However, the actual solar SXR (0.5-5 keV) spectrum is not well known, particularly during quiet periods, as, with few exceptions, this energy range has not been systematically studied in many years. Previous observations include ultra-high-resolution but very narrow-band spectra from crystral spectrometers (e.g. Yohkoh/BCS), or integrated broadband irradiances from photometers (e.g. GOES/XRS, TIMED/XPS, etc.) that lack detailed spectral information. In recent years, broadband measurements with fair energy resolution (~0.5-0.7 keV FWHM) were made by SphinX on CORONAS-Photon and XRS on MESSENGER, although they did not extend below ~1 keV. We present observations of the quiet Sun SXR emission obtained using a new SXR spectrometer flown on the third SDO/EVE underflight calibration rocket (NASA 36.286). The commercial off-the-shelf Amptek X123 silicon drift detector, with an 8-micron Be window and custom aperture, measured the solar SXR emission from ~0.5 to >10 keV with ~0.15 keV FWHM resolution (though, due to hardware limitations, with only ~0.12 keV binning) and 2-sec cadence over ~5 minutes on 23 June 2012. Despite the rising solar cycle, activity on 23 June 2012 was abnormally low, with no visible active regions and GOES XRS emission near 2010 levels; we measured no solar counts above ~4 keV during the observation period. We compare our X123 measurements with spectra and broadband irradiances from other instruments, including the SphinX observations during the deep solar minimum of 2009, and with upper limits of >3 keV quiet Sun emission

  16. Astrophysics and cosmology confront the 17 keV neutrino

    NASA Technical Reports Server (NTRS)

    Kolb, Edward W.; Turner, Michael S.

    1991-01-01

    A host of astrophysical and cosmological arguments severely constrain the properties of a 17 keV Dirac neutrino. Such a neutrino must have interactions beyond those of the standard electroweak theory to reduce its cosmic abundance (through decay or annihilation) by a factor of two hundred. A predicament arises because the additional helicity states of the neutrino necessary to construct a Dirac mass must have interactions strong enough to evade the astrophysical bound from SN 1987A, but weak enough to avoid violating the bound from primordial nucleosynthesis.

  17. Proposed FNAL 750 KeV Linac Injector Upgrade

    SciTech Connect

    Tan, C.Y.; Bollinger, D.S.; Schmidt, C.W.; /Fermilab

    2009-04-01

    The present FNAL linac H{sup -} injector has been operational since 1978 and consists of a magnetron H{sup -} source and a 750 keV Cockcroft-Walton Accelerator. The proposed upgrade to this injector is to replace the present magnetron source having a rectangular aperture with a circular aperture, and to replace the Cockcroft-Walton with a 200 MHz RFQ. Operational experience at other laboratories has shown that the upgraded source and RFQ will be more reliable and require less manpower than the present system.

  18. Astrophysics and cosmology confront the 17-keV neutrino

    NASA Technical Reports Server (NTRS)

    Kolb, Edward W.; Turner, Michael S.

    1991-01-01

    A host of astrophysical and cosmological arguments severely constrain the properties of a 17 keV Dirac neutrino. Such a neutrino must have interactions beyond those of the standard electroweak theory to reduce its cosmic abundance (through decay or annihilation) by a factor of two hundred. A predicament arises because the additional helicity states of the neutrino necessary to construct a Dirac mass must have interactions strong enough to evade the astrophysical bound from SN 1987A, but weak enough to avoid violating the bound from primordial nucleosynthesis.

  19. AAgAtlas 1.0: a human autoantigen database

    PubMed Central

    Wang, Dan; Yang, Liuhui; Zhang, Ping; LaBaer, Joshua; Hermjakob, Henning; Li, Dong; Yu, Xiaobo

    2017-01-01

    Autoantibodies refer to antibodies that target self-antigens, which can play pivotal roles in maintaining homeostasis, distinguishing normal from tumor tissue and trigger autoimmune diseases. In the last three decades, tremendous efforts have been devoted to elucidate the generation, evolution and functions of autoantibodies, as well as their target autoantigens. However, reports of these countless previously identified autoantigens are randomly dispersed in the literature. Here, we constructed an AAgAtlas database 1.0 using text-mining and manual curation. We extracted 45 830 autoantigen-related abstracts and 94 313 sentences from PubMed using the keywords of either ‘autoantigen’ or ‘autoantibody’ or their lexical variants, which were further refined to 25 520 abstracts, 43 253 sentences and 3984 candidates by our bio-entity recognizer based on the Protein Ontology. Finally, we identified 1126 genes as human autoantigens and 1071 related human diseases, with which we constructed a human autoantigen database (AAgAtlas database 1.0). The database provides a user-friendly interface to conveniently browse, retrieve and download human autoantigens as well as their associated diseases. The database is freely accessible at http://biokb.ncpsb.org/aagatlas/. We believe this database will be a valuable resource to track and understand human autoantigens as well as to investigate their functions in basic and translational research. PMID:27924021

  20. CHEETAH 1.0 user`s manual

    SciTech Connect

    Fried, L.E.

    1994-06-24

    CHEETAH is an effort to bring the TIGER thermochemical code into the 1990s. A wide variety of improvements have been made in Version 1.0, and a host of others will be implemented in the future. In CHEETAH 1.0 I have improved the robustness and ease of use of TIGER. All of TIGER`s solvers have been replaced by new algorithms. I find that CHEETAH solves a wider variety of problems with no user intervention (e.g. no guesses for the C-J state) than TIGER did. CHEETAH has been made simpler to use than TIGER; typical use of the code occurs with the new standard run command. I hope that CHEETAH makes the use of thermochemical codes more attractive to practical explosive formulators. In the future I plan to improve the underlying science in CHEETAH. More accurate equations of state will be used in the gas and the condensed phase. A kinetics capability will be added to the code that will predict reaction zone thickness. CHEETAH is currently a numerical implementation of C-J theory. It will,become an implementation of ZND theory. Further ease of use features will eventually be added; an automatic formulator that adjusts concentrations to match desired properties is planned.

  1. SU-E-T-46: A Monte Carlo Investigation of Radiation Interactions with Gold Nanoparticles in Water for 6 MV, 85 KeV and 40 KeV Photon Beams

    SciTech Connect

    Flint, D B; O’Brien, D J; McFadden, C H; Wolfe, T; Krishnan, S; Sawakuchi, G O; Hallacy, T M

    2015-06-15

    Purpose: To determine the effect of gold-nanoparticles (AuNPs) on energy deposition in water for different irradiation conditions. Methods: TOPAS version B12 Monte Carlo code was used to simulate energy deposition in water from monoenergetic 40 keV and 85 keV photon beams and a 6 MV Varian Clinac photon beam (IAEA phase space file, 10x10 cm{sup 2}, SSD 100 cm). For the 40 and 85 keV beams, monoenergetic 2x2 mm{sup 2} parallel beams were used to irradiate a 30x30x10 µm {sup 3} water mini-phantom located at 1.5 cm depth in a 30x30x50 cm{sup 3} water phantom. 5000 AuNPs of 50 nm diameter were randomly distributed inside the mini-phantom. Energy deposition was scored in the mini-phantom with the AuNPs’ material set to gold and then water. For the 6 MV beam, we created another phase space (PHSP) file on the surface of a 2 mm diameter sphere located at 1.5 cm depth in the water phantom. The PHSP file consisted of all particles entering the sphere including backscattered particles. Simulations were then performed using the new PHSP as the source with the mini-phantom centered in a 2 mm diameter water sphere in vacuum. The g4em-livermore reference list was used with “EMRangeMin/EMRangeMax = 100 eV/7 MeV” and “SetProductionCutLowerEdge = 990 eV” to create the new PHSP, and “SetProductionCutLowerEdge = 100 eV” for the mini-phantom simulations. All other parameters were set as defaults (“finalRange = 100 µm”). Results: The addition of AuNPs resulted in an increase in the mini-phantom energy deposition of (7.5 ± 8.7)%, (1.6 ± 8.2)%, and (−0.6 ± 1.1)% for 40 keV, 85 keV and 6 MV beams respectively. Conclusion: Enhanced energy deposition was seen at low photon energies, but decreased with increasing energy. No enhancement was observed for the 6 MV beam. Future work is required to decrease the statistical uncertainties in the simulations. This research is partially supported from institutional funds from the Center for Radiation Oncology Research, The

  2. Measurement of velocity deficit at the downstream of a 1:10 axial hydrokinetic turbine model

    SciTech Connect

    Gunawan, Budi; Neary, Vincent S; Hill, Craig; Chamorro, Leonardo

    2012-01-01

    Wake recovery constrains the downstream spacing and density of turbines that can be deployed in turbine farms and limits the amount of energy that can be produced at a hydrokinetic energy site. This study investigates the wake recovery at the downstream of a 1:10 axial flow turbine model using a pulse-to-pulse coherent Acoustic Doppler Profiler (ADP). In addition, turbine inflow and outflow velocities were measured for calculating the thrust on the turbine. The result shows that the depth-averaged longitudinal velocity recovers to 97% of the inflow velocity at 35 turbine diameter (D) downstream of the turbine.

  3. Deep XMM observations of Draco rule out at the 99 per cent confidence level a dark matter decay origin for the 3.5 keV line

    NASA Astrophysics Data System (ADS)

    Jeltema, Tesla; Profumo, Stefano

    2016-06-01

    We searched for an X-ray line at energies around 3.5 keV in deep, ˜1.6 Ms XMM-Newton observations of the dwarf spheroidal galaxy Draco. No line was found in either the Metal Oxide Semi-conductor (MOS) or the p-type/n-type semiconductor (PN) detectors. The data in this energy range are completely consistent with a single, unfolded power-law modelling the particle background, which dominates at these energies, plus instrumental lines; the addition of a ˜3.5 keV line feature gives no improvement to the fit. The corresponding upper limit on the line flux rules out a dark matter decay origin for the 3.5 keV line found in observations of clusters of galaxies and in the Galactic Centre at greater than 99 per cent confidence level.

  4. Identification of the ~3.55 keV emission line candidate objects across the sky

    NASA Astrophysics Data System (ADS)

    Savchenko, D. O.; Iakubovskyi, D. A.

    2015-12-01

    An emission line at the energy ~3.55 keV detected in different galaxies and galaxy clusters has caused numerous discussions in high-energy astrophysics and particle physics communities. To reveal the origin of the line, we analyzed publicly-available observations of MOS cameras from XMM-Newton cosmic observatory - the instrument with the largest sensitivity for narrow faint X-ray lines - previously combined in X-ray sky maps. Because an extremely large timescale is needed for detailed analysis, we used the wavelet method instead. Extensive simulations of the central part of the Andromeda galaxy are used to check the validity of this method. The resulting list of wavelet detections now contains 235 sky regions. This list will be used in future works for more detailed spectral analysis.

  5. Active detection of shielded SNM with 60-keV neutrons

    SciTech Connect

    Hagmann, C; Dietrich, D; Hall, J; Kerr, P; Nakae, L; Newby, R; Rowland, M; Snyderman, N; Stoeffl, W

    2008-07-08

    Fissile materials, e.g. {sup 235}U and {sup 239}Pu, can be detected non-invasively by active neutron interrogation. A unique characteristic of fissile material exposed to neutrons is the prompt emission of high-energy (fast) fission neutrons. One promising mode of operation subjects the object to a beam of medium-energy (epithermal) neutrons, generated by a proton beam impinging on a Li target. The emergence of fast secondary neutrons then clearly indicates the presence of fissile material. Our interrogation system comprises a low-dose 60-keV neutron generator (5 x 10{sup 6}/s), and a 1 m{sup 2} array of scintillators for fast neutron detection. Preliminary experimental results demonstrate the detectability of small quantities (370 g) of HEU shielded by steel (200 g/cm{sup 2}) or plywood (30 g/cm{sup 2}), with a typical measurement time of 1 min.

  6. keV electron heating in laser-cluster interaction probed by X-ray and electron spectroscopy

    NASA Astrophysics Data System (ADS)

    Yin, H.; Wachter, G.; Deiss, C.; Lemell, C.; Burgdörfer, J.; Lamour, E.; Prigent, C.; Ramond, C.; Rozet, J. P.; Steydli, S.; Trassinelli, M.; Vernhet, D.

    2014-04-01

    The interaction of intense laser pulses with nanoscopic rare-gas clusters provides a testing ground for laser-atom interaction at solid-state densities. We investigate the driven electronic dynamics on the femtosecond time scale both experimentally and theoretically using two complementary observables: the laser intensity dependence of characteristic X-ray emission and of high-energy (keV) electron spectra.

  7. Observations of the Galactic center 511 keV line

    NASA Technical Reports Server (NTRS)

    Gehrels, Neil

    1991-01-01

    A review of observations of the positron annihilation 511 keV line from the Galactic center and plane is presented. Emphasis is given to the new data from balloon observations in 1988 and 1989. The positron annihilation source in the direction of the center was found to be turned on again in 1988 October after being observed in a quiescent state since the early 1980s. There is evidence for variability between May and October in 1988. The new observations give the first data in which the line is spectrally resolved and in which the Galactic center and plane components of the annihilation radiation are independently measured. These data support the two-component model of the emission with a variable point source near the center and a steady-state source distributed along the galactic plane. Comparing measurements of narrow and wide field instruments in the 1980s gives a flux of about 8 x 10 exp -4 photons/sq cm/s for the point source in its high state and a flux of about 1.2 x 10 exp-3 photons/sq cm/s/rad for the galactic plane component with a relatively flat distribution over the central radian. The line width for the point source component is about 3 keV FWHM.

  8. 4,7-Diphenyl-1,10-phenanthroline methanol hemisolvate.

    PubMed

    Martins, João P; Martín-Ramos, Pablo; Sobral, Abílio J F N; Ramos Silva, Manuela

    2013-01-01

    The asymmetric unit of the title compound, C24H16N2·0.5CH3OH, is comprised of two independent bathophenanthroline mol-ecules (systematic name: 4,7-diphenyl-1,10-phenanthroline) and one methanol mol-ecule. The bathophenanthroline mol-ecules are not planar as there is a considerable rotation of all terminal phenyl rings with respect to the central phenanthroline units [dihedral angles in the range 52.21 (12)-62.14 (10)°]. In addition, a non-negligible torsion is apparent in one of the phenanthroline units: the angle between the mean planes of the two pyridine rings is 14.84 (13)°. The methanol solvent mol-ecule is linked to both N atoms of a bathophenanthroline mol-ecule through a bifurcated O-H⋯(N,N) hydrogen bond.

  9. Spectroscopy study of 5-amino-1,10-phenanthroline

    NASA Astrophysics Data System (ADS)

    Ramírez-Silva, Ma. Teresa; Gómez-Hernández, Martín.; Pacheco-Hernández, Ma de Lourdes; Rojas-Hernández, Alberto; Galicia, Laura

    2004-03-01

    Acidity constants for the 5-amino-1,10-phenanthroline (5-Aphen) were determined in aqueous media, using SQUAD and SUPERQUAD programs. Spectrophotometry and potentiometry data were fitted to the best model to enable correlation of the following acidity equilibria: 5-AphenH=5-Aphen+H + (- log K=5.78±0.03 ) and 5-AphenH 2=5-Aphen+2H + (- log K=6.89±0.07 ). UV absorptivity coefficients obtained suggest that the first protonation takes place on the nitrogens of the heterocycle ring and the second protonation could take place on the amino group. As expected, the electrochemical evidence of the 5-Aphen species depends on the degree of protonation.

  10. Wind-US 1.0 Released by NPARC Alliance

    NASA Technical Reports Server (NTRS)

    Towne, Charles E.

    2005-01-01

    The NPARC (National Project for Application-oriented Research in CFD) Alliance has released Version 1.0 of Wind-US, the latest in its line of general-purpose, multizone, compressible-flow Navier-Stokes solvers. The NPARC Alliance is a formal partnership between the NASA Glenn Research Center and the Air Force Arnold Engineering Development Center, with additional significant involvement by the Boeing Company s Phantom Works Group, whose mission is to provide an applications-oriented computational fluid dynamics (CFD) system primarily for aerospace flow simulation. The alliance is committed to the long-range maintenance and improvement of this capability, with teams focused on user support, code development, and validation.

  11. NIMS Radiance Point Spectra of Gaspra V1.0

    NASA Astrophysics Data System (ADS)

    Granahan, J. C.

    2014-10-01

    This data volume contains radiometrically corrected point spectra of asteroid 951 as acquired by the Galileo spacecraft Near Infrared Mapping Spectrometer (NIMS) on October 29, 1991. They record the spectra collected as the Galileo spacecraft approached the target asteroid. These data are products of the calibration of the raw data number files gap015tn.qub, gap035tn.qub, gap036tn.qub, gap037tn.qub, and gap038tn.qub (DATA SET ID ='GO-A-NIMS-3 TUBE-V1.0') with calibration factors acquired during the first Earth/Moon encounter of the Galileo mission. These raw data .qub files are archived in the Imaging Node of the NASA Planetary Data System (PDS). The calibrated spectra consist of radiance measurements for wavelengths between 0.7 - 5.2 micrometers.

  12. Verification and validation of RADMODL Version 1.0

    SciTech Connect

    Kimball, K.D.

    1993-03-01

    RADMODL is a system of linked computer codes designed to calculate the radiation environment following an accident in which nuclear materials are released. The RADMODL code and the corresponding Verification and Validation (V&V) calculations (Appendix A), were developed for Westinghouse Savannah River Company (WSRC) by EGS Corporation (EGS). Each module of RADMODL is an independent code and was verified separately. The full system was validated by comparing the output of the various modules with the corresponding output of a previously verified version of the modules. The results of the verification and validation tests show that RADMODL correctly calculates the transport of radionuclides and radiation doses. As a result of this verification and validation effort, RADMODL Version 1.0 is certified for use in calculating the radiation environment following an accident.

  13. Spectroscopy study of 5-amino-1,10-phenanthroline.

    PubMed

    Ramírez-Silva, Ma Teresa; Gómez-Hernández, Martín; Pacheco-Hernández, Ma Lourdes; Rojas-Hernández, Alberto; Galicia, Laura

    2004-03-01

    Acidity constants for the 5-amino-1,10-phenanthroline (5-Aphen) were determined in aqueous media, using SQUAD and SUPERQUAD programs. Spectrophotometry and potentiometry data were fitted to the best model to enable correlation of the following acidity equilibria: 5-AphenH = 5-Aphen + H+ (-log K = 5.78 +/= 0.03) and 5-AphenH2 = 5-AphenH2 = 5-Aphen + 2H+ (-log K = 6.89 +/= 0.07). UV absorptivity coefficients obtained suggest that the first protonation takes place on the nitrogens of the heterocycle ring and the second protonation could take place on the amino group. As expected, the electrochemical evidence of the 5-Aphen species depends on the degree of protonation.

  14. A coincidence study of electron and positron impact ionization of Ar (3p) at 1 keV

    NASA Astrophysics Data System (ADS)

    Campeanu, Radu I.; Walters, James H. R.; Whelan, Colm T.

    2015-10-01

    Distorted-wave calculations of the triple differential cross section (TDCS) are presented for electron and positron impact ionization of Ar(3p) in coplanar asymmetric geometry at an impact energy of 1 keV and are compared with a recent experiment. The experiment indicates that the positron TDCS is generally larger than the equivalent electron TDCS. It is shown that the magnitude of the TDCS is extremely sensitive to the energy of the ejected electron and that only when the cross section is averaged over energy do we get a reasonable agreement with experiment.

  15. A coincidence study of electron and positron impact ionization of Ar (3p) at 1 keV

    NASA Astrophysics Data System (ADS)

    Campeanu, Radu I.; Walters, James H. R.; Whelan, Colm T.

    2015-10-01

    Distorted-wave calculations of the triple differential cross section (TDCS) are presented for electron and positron impact ionization of Ar(3 p) in coplanar asymmetric geometry at an impact energy of 1 keV and are compared with a recent experiment. The experiment indicates that the positron TDCS is generally larger than the equivalent electron TDCS. It is shown that the magnitude of the TDCS is extremely sensitive to the energy of the ejected electron and that only when the cross section is averaged over energy do we get a reasonable agreement with experiment.

  16. Charge transfer and electronic excitation in collisions of protons with water molecules below 10keV

    NASA Astrophysics Data System (ADS)

    Mada, Shogo; Hida, Ken-Nosuke; Kimura, Mineo; Pichl, Lukáš; Liebermann, Heinz-Peter; Li, Yan; Buenker, Robert J.

    2007-02-01

    Charge transfer and electronic excitation processes for H++H2O collisions are investigated theoretically below 10keV . Molecular-orbital close-coupling approach is employed for scattering dynamics, while an ab initio multireference single- and double-configuration interaction method is used for the determination of molecular states. The present results for charge transfer show rather weak energy dependence in the energy range from 10keV down to a few tens of eV with very slowly varying cross-section value of 4-13×10-16cm2 , and are found to be in excellent agreement with experimental measurements by Lindsay [Phys. Rev. A 55, 3945 (1997)] where the energy in the experiment and theory overlaps. The electronic-excitation cross sections are found to be much smaller than those for the charge transfer, but increase rapidly and become comparable to charge transfer at a few keV. Most of the water molecular ions and excited species produced in the collision are unstable and soon undergo dissociation; some insight into the fragmentation process and the fragmented species is given.

  17. Charge transfer and electronic excitation in collisions of protons with water molecules below 10 keV

    SciTech Connect

    Mada, Shogo; Hida, Ken-nosuke; Kimura, Mineo; Pichl, Lukas; Liebermann, Heinz-Peter; Li, Yan; Buenker, Robert J.

    2007-02-15

    Charge transfer and electronic excitation processes for H{sup +}+H{sub 2}O collisions are investigated theoretically below 10 keV. Molecular-orbital close-coupling approach is employed for scattering dynamics, while an ab initio multireference single- and double-configuration interaction method is used for the determination of molecular states. The present results for charge transfer show rather weak energy dependence in the energy range from 10 keV down to a few tens of eV with very slowly varying cross-section value of 4-13x10{sup -16} cm{sup 2}, and are found to be in excellent agreement with experimental measurements by Lindsay et al. [Phys. Rev. A 55, 3945 (1997)] where the energy in the experiment and theory overlaps. The electronic-excitation cross sections are found to be much smaller than those for the charge transfer, but increase rapidly and become comparable to charge transfer at a few keV. Most of the water molecular ions and excited species produced in the collision are unstable and soon undergo dissociation; some insight into the fragmentation process and the fragmented species is given.

  18. Albedo factors of some elements in the atomic number range 26≤Z≤79 for 59.54keV.

    PubMed

    Yılmaz, Demet; Uzunoğlu, Zeynep; Demir, Celalettin

    2017-04-01

    In this study, we aimed to determine the albedo factors for Fe, Co, Ni, Cu, Zr, Mo, Ag, Dy, Yb, and Au. Albedo factors were investigated experimentally for 59.54keV photon energy by using an HPGe detector with a resolution of 182eV at 5.9keV. Albedo number (AN), albedo energy (AE), and albedo dose (AD) were plotted as a function of atomic number of the target. It was observed that albedo factors decreased with increasing atomic number. In addition, there was a good third-order polynomial relationship between the albedo factors and atomic number.

  19. Calibration of semiconductor detectors in the 200-8500 keV range at VNIIM.

    PubMed

    Tereshchenko, Evgeny E; Moiseev, Nikolay

    2012-09-01

    At the ionising radiation department of the D.I. Mendeleyev Institute for Metrology, a semiconductor detector was calibrated in the energy range 200-8500 keV using (n,2γ) and (n,γ) reactions. Separate cylindrical targets (77 mm diameter and 10mm height) were made from mercuric sulphate, sodium chloride and metallic titanium. A (252)Cf spontaneous fission neutron source, placed in 150 mm diameter polyethylene ball, was used to generate thermal neutrons. The optimal target dimensions were determined taking into account the thermal neutron cross-sections and gamma-radiation attenuations in the target materials. The influence of the background radiation induced by neutrons from the walls, floors and ceilings was also taken into account. The shapes of the efficiency curves for point and volume sources in the 200-8500 keV range have been investigated. The experimental results are in good agreement with Monte-Carlo calculations. The emission rate of the 6.13 MeV photons from a (238)Pu-(13)C source was determined with an expanded uncertainty, U(c), of 10% (k=2).

  20. Dose dependence of surface damage profiles for Ge(111) irradiated with 3 keV Ar +

    NASA Astrophysics Data System (ADS)

    Kido, Yoshiaki; Nakano, Hirohiko

    1990-12-01

    The damage profiles of 3 keV Ar + -irradiated Ge(111) were measured by medium energy ion scattering (MEIS) with 220 keV H + beams. A depth resolution of 0.5 nm has been achieved using an electrostatic toroidal analyzer. With doses over 1 × 10 14Ar+/ cm2 at room temperature, an amorphous layer is formed and the amorphous layer thickness is saturated by a dose of 1 × 10 15Ar+/ cm2. The saturated amorphous layer thickness of 12-13 nm obtained is in good agreement with that observed by a cross section transmission electron microscope. The dose dependence of the induced defects derived from MEIS is consistent with that determined by electron channeling pattern analysis. The amorphized damage profiles determined directly by MEIS agree well with those obtained by solving the rate equation using the unsaturated initial defect profile for a dose of 2 × 10 13Ar+/ cm2 and assuming a sputtering rate of 2.4-3.0.

  1. Building the Fire Energetics and Emissions Research (FEER) Smoke Emissions Inventory Version 1.0

    NASA Technical Reports Server (NTRS)

    Ellison, Luke; Ichoku, Charles; Zhang, Feng; Wang, Jun

    2014-01-01

    The Fire Energetics and Emissions Research (FEER) group's new coefficient of emission global gridded product at 1x1 resolution that directly relates fire readiative energy (FRE) to smoke aerosol release, FEERv1.0 Ce, made its public debut in August 2013. Since then, steps have been taken to generate corresponding maps and totals of total particulate matter (PM) emissions using different sources of FRE, and subsequently to simulate the resulting PM(sub 2.5) in the WRF-Chem 3.5 model using emission rates from FEERv1.0 as well as other standard biomass burning emission inventories. An flowchart of the FEER algorithm to calculate Ce is outlined here along with a display of the resulting emissions of total PM globally and also regionally. The modeling results from the WRF-Chem3.5 simulations are also shown.

  2. K-(alpha) Radiography at 20-100 keV Using Short-Pulse Lasers

    SciTech Connect

    Park, H S; Chambers, D; Clarke, R; Eagleton, R; Giraldez, E; Goldsack, T; Heathcote, R; Izumi, N; Key, M; King, J; Koch, J; Landen, O L; Mackinnon, A; Nikroo, A; Patel, P; Pasley, J; Remington, B; Robey, H; Snavely, R; Steinman, D; Stephenson, R; Stoeckl, C; Storm, M; Tabak, M; Theobald, W; Town, R J

    2005-08-29

    X-ray radiography is an important tool for diagnosing and imaging planar and convergent hydrodynamics phenomena for laser experiments. Until now, hydrodynamics experiments at Omega and NIF utilize E{sub x-ray} < 9 keV backlighter x-rays emitted by thermal plasmas. However, future experiments will need to diagnose larger and denser targets and will require x-ray probes of energies from 20-100 keV and possibly up to 1 MeV. Hard K-{alpha} x-ray photons can be created through high-energy electron interactions in the target material after irradiation by petawatt-class high-intensity-short-pulse lasers with > 10{sup 17} W/cm{sup 2}. We have performed several experiments on the JanUSP, and the Vulcan 100TW, and Vulcan Petawatt lasers to understand K-{alpha} sources and to test radiography concepts. 1-D radiography using an edge-on foil and 2-D radiography using buried wires and cone-fiber targets were tested. We find that 1-D thin edge-on foils can have imaging resolution better than 10 {micro}m. Micro volume targets produce bright sources with measured conversion efficiency from laser energy to x-ray photons of {approx} 1 x 10{sup -5}. This level of conversion may not be enough for 2-D point projection radiography. A comparison of our experimental measurements of small volume sources with the LSP/PIC simulation show similar K-{alpha} creation profiles but discrepancy in absolute yields.

  3. Land-Use Portfolio Modeler, Version 1.0

    USGS Publications Warehouse

    Taketa, Richard; Hong, Makiko

    2010-01-01

    Natural hazards pose significant threats to the public safety and economic health of many communities throughout the world. Community leaders and decision-makers continually face the challenges of planning and allocating limited resources to invest in protecting their communities against catastrophic losses from natural-hazard events. Public efforts to assess community vulnerability and encourage loss-reduction measures through mitigation often focused on either aggregating site-specific estimates or adopting standards based upon broad assumptions about regional risks. The site-specific method usually provided the most accurate estimates, but was prohibitively expensive, whereas regional risk assessments were often too general to be of practical use. Policy makers lacked a systematic and quantitative method for conducting a regional-scale risk assessment of natural hazards. In response, Bernknopf and others developed the portfolio model, an intermediate-scale approach to assessing natural-hazard risks and mitigation policy alternatives. The basis for the portfolio-model approach was inspired by financial portfolio theory, which prescribes a method of optimizing return on investment while reducing risk by diversifying investments in different security types. In this context, a security type represents a unique combination of features and hazard-risk level, while financial return is defined as the reduction in losses resulting from an investment in mitigation of chosen securities. Features are selected for mitigation and are modeled like investment portfolios. Earth-science and economic data for the features are combined and processed in order to analyze each of the portfolios, which are then used to evaluate the benefits of mitigating the risk in selected locations. Ultimately, the decision maker seeks to choose a portfolio representing a mitigation policy that maximizes the expected return-on-investment, while minimizing the uncertainty associated with that return-on-investment. The portfolio model, now known as the Land-Use Portfolio Model (LUPM), provided the framework for the development of the Land-Use Portfolio Modeler, Version 1.0 software (LUPM v1.0). The software provides a geographic information system (GIS)-based modeling tool for evaluating alternative risk-reduction mitigation strategies for specific natural-hazard events. The modeler uses information about a specific natural-hazard event and the features exposed to that event within the targeted study region to derive a measure of a given mitigation strategy`s effectiveness. Harnessing the spatial capabilities of a GIS enables the tool to provide a rich, interactive mapping environment in which users can create, analyze, visualize, and compare different

  4. Magnetospheric plasma modeling (0-100 keV)

    NASA Technical Reports Server (NTRS)

    Garrett, H. B.; Spitale, G. C.

    1985-01-01

    Spacecraft surface charging, which is primarily a current balance phenomenon, is in general a function of the dominant currents to and from the vehicle's surface. Within the near-earth magnetosphere the dominant currents to the surface are the ambient space plasma fluxes between approximately 0 and 100 keV. A major effort to understand the near-earth environment was initiated when spacecraft charging became a major issue. The present paper has the objective to summarize the basic features of the models which have resulted from this effort. A description is given of four categories of models, based primarily on the degree of empirical and theoretical input. Types of quantitative models are discussed, taking into account definitions, statistical models, analytic models, static models, and time-dependent models. Engineering models are also considered, giving attention to baseline models and 'worst-case' models.

  5. iGeoT v1.0

    SciTech Connect

    Spycher, Nicolas; Finsterle, Stefan

    2016-11-01

    iGeoT v1.0 automates into a stand-alone computer program the multicomponent chemical geothermometry code GeoT v2.1 and the numerical optimization engine of iTOUGH2. iGeoT allows for optimizations of GeoT runs using multiple water chemical analyses. The underlying geothermometry method is that previously developed by Reed and Spycher (1984) using the computed saturation indices of multiple minerals. GeoT automatically reconstitutes deep fluid compositions and estimates reservoir temperature from statistical evaluation of computed mineral saturation indices. The output include estimated temperatures following various statistical methods and their range of uncertainty. The computer program also outputs temperatures predicted using classical geothermometers. Input parameters include water composition and, optionally, gas composition, fraction of gas discharge, dilution/evaporation factor (in case of boiling or mixing with dilute waters), and end-member water composition (in case of mixing with other non-dilute waters). The dilution/evaporation factor, fraction of gas discharge, and concentration of various aqueous and gas species can be automatically estimated by numerical optimization. This program was designed for geothermal applications.

  6. EOS7C-ECBM Version 1.0

    SciTech Connect

    2012-11-14

    EOS7C is an equation of state module for the TOUGH2 program for CO2 or N2 in Methane (CH4) Reservoirs. In the present work, additions have been made to the EOS7C Version 1.0 module to include the Enhanced Coal Bed Methane (ECBM) modifications developed by Webb (2003). In addition, the Dusty Gas Model for gas-phase diffusion (Webb 2001) has been included. The ECBM modification to the EOS7C equation of state incorporate the extended Langmuir isothem for sorbing gases, including the change in porosity associated with the sorbed gas mass. Comparison to hand calculations for pure gas and binary mixture shows very good agreement. Application to a CO2 well injection problem by Law et al. (2002). The Dusty Model modification add options to calculate gas diffusion using the Dusty-Gas Model including separate and coupled approaches. Comparison to low-permeability pure gas diffusion data shows excellent agreement. The results from the DGM are compared to the Fick's Law behavior for diffusion across a capillary fringe. The differences between the models are small due to the relatively high permeability (10-11 m2) of the problem.

  7. NAS Parallel Benchmark Results 11-96. 1.0

    NASA Technical Reports Server (NTRS)

    Bailey, David H.; Bailey, David; Chancellor, Marisa K. (Technical Monitor)

    1997-01-01

    The NAS Parallel Benchmarks have been developed at NASA Ames Research Center to study the performance of parallel supercomputers. The eight benchmark problems are specified in a "pencil and paper" fashion. In other words, the complete details of the problem to be solved are given in a technical document, and except for a few restrictions, benchmarkers are free to select the language constructs and implementation techniques best suited for a particular system. These results represent the best results that have been reported to us by the vendors for the specific 3 systems listed. In this report, we present new NPB (Version 1.0) performance results for the following systems: DEC Alpha Server 8400 5/440, Fujitsu VPP Series (VX, VPP300, and VPP700), HP/Convex Exemplar SPP2000, IBM RS/6000 SP P2SC node (120 MHz), NEC SX-4/32, SGI/CRAY T3E, SGI Origin200, and SGI Origin2000. We also report High Performance Fortran (HPF) based NPB results for IBM SP2 Wide Nodes, HP/Convex Exemplar SPP2000, and SGI/CRAY T3D. These results have been submitted by Applied Parallel Research (APR) and Portland Group Inc. (PGI). We also present sustained performance per dollar for Class B LU, SP and BT benchmarks.

  8. Desorption of cluster ions from solid Ne by low-energy ion impact.

    PubMed

    Tachibana, T; Fukai, K; Koizumi, T; Hirayama, T

    2010-12-01

    We investigated Ne(+) ions and Ne(n)(+) (n = 2-20) cluster ions desorbed from the surface of solid Ne by 1.0 keV Ar(+) ion impact. Kinetic energy analysis shows a considerably narrower energy distribution for Ne(n)(+) (n ≥ 3) ions than for Ne(n)(+) (n = 1, 2) ions. The dependence of ion yields on Ne film thickness indicates that cluster ions (n ≥ 3) are desorbed only from relatively thick films. We conclude that desorbed ions grow into large cluster ions during the outflow of deep bulk atoms to the vacuum.

  9. Demonstration of a 13 keV Kr K-shell X-Ray Source at the National Ignition Facility

    NASA Astrophysics Data System (ADS)

    Fournier, K. B.; May, M. J.; Colvin, J. D.; Barrios, M. A.; Patterson, J. R.; Regan, S. P.

    2013-10-01

    We report 3% conversion efficiency of laser energy into Kr K-shell (~13 keV) radiation, consistent with theoretical predictions. This is ~10 × greater than previous work. The emission was produced from a 4.1 mm diameter, 4 mm tall gas pipe target filled with 1.2 or 1.5 atm of Kr gas. 160 of the NIF laser beams deposited ~700 kJ of 3 ω light into the target in a ~140 TW, 5.0 ns duration square pulse. This laser configuration sufficiently heated the targets to optimize the K-shell x-ray emission. The Dante diagnostics measured ~5 TW into 4 π solid angle of >=12 keV x rays for ~4 ns, which includes both continuum emission and flux in the Kr Heα line at 13 keV. This work was performed under the auspices of the U.S. Department of Energy by Lawrence Livermore National Laboratory under Contract DE-AC52-07NA27344. This work was supported by the Defense Threat Reduction Agency under the intera- gency agreements 10027-1420 and 10027-6167.

  10. SMM observations of gamma-ray transients. 2: A search for gamma-ray lines between 400 and 600 keV from the Crab Nebula

    NASA Technical Reports Server (NTRS)

    Harris, Michael J.; Share, Gerald H.; Leising, Mark D.

    1994-01-01

    We have search spectra obtained by the Solar Maximum Mission Gamma-Ray Spectrometer during 1981-1988 for evidence of transient gamma-ray lines from the Crab Nebula which have been reported by previous experiments at energies 400-460 keV and 539 keV. We find no evidence for significant emission in any of these lines on time scales between aproximately 1 day and approximately 1 yr. Our 3 sigma upper limits on the transient flux during 1 d intervals are approximately equal to 2.2 x 10(exp -3) photons/sq cm/s for narrow lines at any energy, and approximately equal to 2.9 x 10(exp -3) photons/sq cm/s for the 539 keV line if it is as broad as 42 keV Full Width at Half Maximum (FWHM). We also searched our data during the approximately 5 hr period on 1981 June 6 during which Owens, Myers, & Thompson (1985) reported a strong line at 405 keV. We detected no line down to a 3 upper sigma limit of 3.3 x 10(exp -3) photons/sq cm/s in disagreement with the flux 7.2 +/- 2.1 x 10(exp -3) photos/sq cm/s measured by Owens et al.

  11. Where do the 3.5 keV photons come from? A morphological study of the Galactic Center and of Perseus

    SciTech Connect

    Carlson, Eric; Jeltema, Tesla; Profumo, Stefano E-mail: tesla@ucsc.edu

    2015-02-01

    We test the origin of the 3.5 keV line photons by analyzing the morphology of the emission at that energy from the Galactic Center and from the Perseus cluster of galaxies. We employ a variety of different templates to model the continuum emission and analyze the resulting radial and azimuthal distribution of the residual emission. We then perform a pixel-by-pixel binned likelihood analysis including line emission templates and dark matter templates and assess the correlation of the 3.5 keV emission with these templates. We conclude that the radial and azimuthal distribution of the residual emission is incompatible with a dark matter origin for both the Galactic center and Perseus; the Galactic center 3.5 keV line photons trace the morphology of lines at comparable energy, while the Perseus 3.5 keV photons are highly correlated with the cluster's cool core, and exhibit a morphology incompatible with dark matter decay. The template analysis additionally allows us to set the most stringent constraints to date on lines in the 3.5 keV range from dark matter decay.

  12. A highly stable 30 keV proton accelerator for studies of angular detection efficiency on Si detectors

    NASA Astrophysics Data System (ADS)

    Salas Bacci, Americo; Baessler, Stefan; Carr, Peter; Hefele, Thomas; Pocanic, Dinko; Roane, Nicholas; Ross, Aaron; Slater, R.; Smith, Alexander; Toth, Csaba; Warner, Dane; Zamperini, Shawn; Zotev, Panaiot; Nab experiment Collaboration

    2017-01-01

    The Nab experiment at the SNS measures the electron-neutrino correlation parameter and the Fierz interference term in free neutron beta decay by measuring in coincidence the electron energy and proton momentum in a magnetic spectrometer with two Si detectors. These large area, thick, and 127-hexagonal segmented Si detectors have to be carefully characterized for optimal performance and for control of systematic errors. The angular detection efficiency of 30 keV proton incident on Si is an important part of this studies. We will present the design, simulation, operation, and detection of 30 keV H+ and H2+as well as results to control the beam stability by the correlation of both detected ion signals. At present we have reached beam stability of (1.2 +/-1.3)E-7/sec.

  13. Motion of 3-6 keV Nonthermal Sources Along the Legs of a Flare Loop

    NASA Technical Reports Server (NTRS)

    Sui, Linhui; Holman, Gordon D.; Dennis, Brian R.

    2007-01-01

    Observations of nonthermal X-ray sources me critical to studying electron acceleration and transport in solar flares. Strong thermal emission radiated from the preheated plasma before the flare impulsive phase often makes it difficult to detect low-energy X-ray sources that are produced by relatively low-energy nonthermal electrons. Knowledge of the distribution of these low-energy nonthermal electrons is particularly important in determining the total nonthermal electron energy in solar flares. We report on an 'early impulsive flare' in which impulsive hard X-ray emission was seen early in the flare before the soft X-ray emission had risen significantly, indicating limited plasma pre-heating. Early in the flare, RHESSI < 25 keV images show coronal sources that moved first downward and then upwards along the legs of a flare loop. In particular, the 3-6 keV source appeared as a single coronal source at the start of the flare, and then it involved into two coronal sources moving down along the two legs of the loop. After nearly reaching the two footpoints at the hard X-ray peak, the two sources moved back up to the looptop again. RHESSI images and light curves all indicate that nonthermal emission dominated at energies as low as 3-6 keV. We suggest that the evolution of both the spectral index and the low-energy cutoff of the injected electron distribution could result in the accelerated electrons reaching a lower altitude along the legs of the dense flare loop and hence result in the observed downward and upward motions of the nonthermal sources.

  14. Preliminary resolved resonance region evaluation of copper-63 from 0 to 300 keV

    SciTech Connect

    Sobes, V.; Forget, B.; Leal, L.; Guber, K.

    2012-07-01

    A new preliminary evaluation of Cu-63 was done in the energy region from 0 to 300 keV extending the resolved resonance region of the previous, ENDF/B-VII.0, evaluation three-fold. The new evaluation was based on three experimental transmission data sets; two measured at the Oak Ridge Electron Linear Accelerator (ORELA) and one from the Massachusetts Inst. of Technology Nuclear Reactor (MITR). A total of 275 new resonances were identified and a corresponding set of external resonances was approximated to mock up the external levels. The negative external levels (bound level) were modified to match the thermal cross section values. A preliminary benchmarking calculation was made using 11 ICSBEP benchmarks. This work is in support of the DOE Nuclear Criticality Safety Program. (authors)

  15. Isotope Shifts in the TiO B- X (1-0) Band

    NASA Astrophysics Data System (ADS)

    Amiot, C.; Luc, P.; Vetter, R.

    2002-08-01

    The absorption spectrum of the B3Π- X3Δ (1-0) band of the TiO molecule has been studied at sub-Doppler resolution by crossing an effusive beam of TiO with a cw tunable laser beam and by collecting the induced fluorescence light. The five bands involving the 46Ti, 47Ti, 48Ti, 49Ti, and 50Ti isotopic species have been observed and interpreted. A simultaneous analysis of the five isotopic data leads to accurate molecular constants and energy levels for the B3Π electronic state.

  16. The SeaFlux Turbulent Flux Dataset Version 1.0 Documentation

    NASA Technical Reports Server (NTRS)

    Clayson, Carol Anne; Roberts, J. Brent; Bogdanoff, Alec S.

    2012-01-01

    Under the auspices of the World Climate Research Programme (WCRP) Global Energy and Water cycle EXperiment (GEWEX) Data and Assessment Panel (GDAP), the SeaFlux Project was created to investigate producing a high-resolution satellite-based dataset of surface turbulent fluxes over the global oceans. The most current release of the SeaFlux product is Version 1.0; this represents the initial release of turbulent surface heat fluxes, associated near-surface variables including a diurnally varying sea surface temperature.

  17. Operational cooling tower model (CTTOOL V1.0)

    SciTech Connect

    Aleman, S.; LocalDomainServers, L.; Garrett, A.

    2015-01-01

    Mechanical draft cooling towers (MDCT’s) are widely used to remove waste heat from industrial processes, including suspected proliferators of weapons of mass destruction (WMD). The temperature of the air being exhausted from the MDCT is proportional to the amount of thermal energy being removed from the process cooling water, although ambient weather conditions and cooling water flow rate must be known or estimated to calculate the rate of thermal energy dissipation (Q). It is theoretically possible to derive MDCT air exhaust temperatures from thermal images taken from a remote sensor. A numerical model of a MDCT is required to translate the air exhaust temperature to a Q. This report describes the MDCT model developed by the Problem Centered Integrated Analysis (PCIA) program that was designed to perform those computational tasks. The PCIA program is a collaborative effort between the Savannah River National Laboratory (SRNL), the Northrop-Grumman Corporation (NG) and the Aerospace Corporation (AERO).

  18. Inner Magnetosphere keV Ion Drift Path Boundaries as Observed by the Van Allen Probes

    NASA Astrophysics Data System (ADS)

    Strangeway, R. J.; Zhang, J.; Larsen, B.

    2014-12-01

    The drifts of keV ions in the inner magnetosphere are controlled by both electric field drifts and gradient and curvature (i.e., magnetic field) drifts, and further the magnetic field drifts oppose the corotation electric field drift in the dusk local time sector. Consequently, the ion drift paths can be quite complicated with the medium-energy ions drifting close to the Earth, but still being on open drift paths. In addition, structure in the energy-time spectrograms can be a consequence of either particle injection or particle loss. In order to distinguish between the two we will compare the energy-time spectrograms acquired with the Helium Oxygen Proton Electron (HOPE) mass spectrometer on board the Van Allen Probes with predictions of drift path boundaries. The simplest model assumes a uniform convection electric field and dipole model field, and we will use this a starting point for the comparison. The model can be modified to include shielding of the convection electric field, and rotation in local time of the zero-energy dusk-side stagnation point. As an additional check of the model we will compare the electric field used in the model with the electric field as measured by the Van Allen Probes, as well as the validity of using a dipole magnetic field through comparison with the measured magnetic field.

  19. Making channeling visible: keV noble gas ion trails on Pt(111)

    NASA Astrophysics Data System (ADS)

    Redinger, A.; Standop, S.; Rosandi, Y.; Urbassek, H. M.; Michely, T.

    2011-01-01

    The impact of argon and xenon noble gas ions on Pt(111) in grazing incidence geometry are studied through direct comparison of scanning tunneling microscopy images and molecular dynamics simulations. The energy range investigated is 1-15 keV and the angles of incidence with respect to the surface normal are between 78.5° and 88°. The focus of the paper is on events where ions gently enter the crystal at steps and are guided in channels between the top most layers of the crystal. The trajectories of the subsurface channeled ions are visible as trails of surface damage. The mechanism of trail formation is analyzed using simulations and analytical theory. Significant differences between Xe+ and Ar+ projectiles in damage, in the onset energy of subsurface channeling as well as in ion energy dependence of trail length and appearance are traced back to the projectile and ion energy dependence of the stopping force. The asymmetry of damage production with respect to the ion trajectory direction is explained through the details of the channel shape and subchannel structure as calculated from the continuum approximation of the channel potential. Measured and simulated channel switching in directions normal and parallel to the surface as well as an increase of ions entering into channels from the perfect surface with increasing angles of incidence are discussed.

  20. ON THE SPECTRAL HARDENING AT {approx}>300 keV IN SOLAR FLARES

    SciTech Connect

    Li, G.; Kong, X.; Zank, G.; Chen, Y.

    2013-05-20

    It has long been noted that the spectra of observed continuum emissions in many solar flares are consistent with double power laws with a hardening at energies {approx}>300 keV. It is now widely believed that at least in electron-dominated events, the hardening in the photon spectrum reflects an intrinsic hardening in the source electron spectrum. In this paper, we point out that a power-law spectrum of electrons with a hardening at high energies can be explained by the diffusive shock acceleration of electrons at a termination shock with a finite width. Our suggestion is based on an early analytical work by Drury et al., where the steady-state transport equation at a shock with a tanh profile was solved for a p-independent diffusion coefficient. Numerical simulations with a p-dependent diffusion coefficient show hardenings in the accelerated electron spectrum that are comparable with observations. One necessary condition for our proposed scenario to work is that high-energy electrons resonate with the inertial range of the MHD turbulence and low-energy electrons resonate with the dissipation range of the MHD turbulence at the acceleration site, and the spectrum of the dissipation range {approx}k {sup -2.7}. A {approx}k {sup -2.7} dissipation range spectrum is consistent with recent solar wind observations.

  1. LCCP Desktop Application v1.0 Engineering Reference

    SciTech Connect

    Beshr, Mohamed; Aute, Vikrant

    2014-04-01

    This Life Cycle Climate Performance (LCCP) Desktop Application Engineering Reference is divided into three parts. The first part of the guide, consisting of the LCCP objective, literature review, and mathematical background, is presented in Sections 2-4. The second part of the guide (given in Sections 5-10) provides a description of the input data required by the LCCP desktop application, including each of the input pages (Application Information, Load Information, and Simulation Information) and details for interfacing the LCCP Desktop Application with the VapCyc and EnergyPlus simulation programs. The third part of the guide (given in Section 11) describes the various interfaces of the LCCP code.

  2. Comparison between MCNP and PENELOPE for the simulation of X-ray spectra in electron microscopy in the keV range

    NASA Astrophysics Data System (ADS)

    Roet, D.; Ceballos, C.; Van Espen, P.

    2006-10-01

    In this paper two Monte Carlo codes, MCNP (version 4C2) and PENELOPE (version 2001), were used in a cluster environment to simulate the X-ray spectra emerging from bombarding pure element bulk targets with mono energetic electrons in the keV range (30 keV). The simulation results were compared to experimental data measured on a JEOL-6300 electron microscope with energy dispersive X-ray detector. The results from both codes were compared amongst each other as to find the best in terms of accuracy, ease of use and speed of the calculations.

  3. ecode - Electron Transport Algorithm Testing v. 1.0

    SciTech Connect

    Franke, Brian C.; Olson, Aaron J.; Bruss, Donald Eugene; Laub, Thomas W.; Crawford, Martin J; Kenseck, Ronald P.; Prinja, Anil

    2016-10-05

    ecode is a Monte Carlo code used for testing algorithms related to electron transport. The code can read basic physics parameters, such as energy-dependent stopping powers and screening parameters. The code permits simple planar geometries of slabs or cubes. Parallelization consists of domain replication, with work distributed at the start of the calculation and statistical results gathered at the end of the calculation. Some basic routines (such as input parsing, random number generation, and statistics processing) are shared with the Integrated Tiger Series codes. A variety of algorithms for uncertainty propagation are incorporated based on the stochastic collocation and stochastic Galerkin methods. These permit uncertainty only in the total and angular scattering cross sections. The code contains algorithms for simulating stochastic mixtures of two materials. The physics is approximate, ranging from mono-energetic and isotropic scattering to screened Rutherford angular scattering and Rutherford energy-loss scattering (simple electron transport models). No production of secondary particles is implemented, and no photon physics is implemented.

  4. Measurement of the Erc .m .=259 keV resonance in the 14N(p ,γ )15O reaction

    NASA Astrophysics Data System (ADS)

    Daigle, S.; Kelly, K. J.; Champagne, A. E.; Buckner, M. Q.; Iliadis, C.; Howard, C.

    2016-08-01

    The 14N(p ,γ )15O reaction regulates the power generated by the CN cycle and thus impacts the structure and evolution of every star at some point in its life. The lowest positive-energy resonance in this reaction is located at Erc .m .=259 keV, too high in energy to strongly influence quiescent stellar burning. However, the strength of this resonance is used as a cross-section normalization for lower-energy measurements of this reaction. We report on new measurements of the energy, strength, and γ -ray branching ratios for the 259-keV resonance, using different detection and data-analysis schemes. We have also reevaluated previous results, where possible. Our new recommended strength of ω γ =12.6 (3 ) meV is in agreement with the previous value of 13.1(6) meV, but is more precise and thus provides a more reliable normalization for low-energy (p ,γ ) measurements.

  5. MsSpec-1.0: A multiple scattering package for electron spectroscopies in material science

    NASA Astrophysics Data System (ADS)

    Sébilleau, Didier; Natoli, Calogero; Gavaza, George M.; Zhao, Haifeng; Da Pieve, Fabiana; Hatada, Keisuke

    2011-12-01

    We present a multiple scattering package to calculate the cross-section of various spectroscopies namely photoelectron diffraction (PED), Auger electron diffraction (AED), X-ray absorption (XAS), low-energy electron diffraction (LEED) and Auger photoelectron coincidence spectroscopy (APECS). This package is composed of three main codes, computing respectively the cluster, the potential and the cross-section. In the latter case, in order to cover a range of energies as wide as possible, three different algorithms are provided to perform the multiple scattering calculation: full matrix inversion, series expansion or correlation expansion of the multiple scattering matrix. Numerous other small Fortran codes or bash/csh shell scripts are also provided to perform specific tasks. The cross-section code is built by the user from a library of subroutines using a makefile. Program summaryProgram title: MsSpec-1.0 Catalogue identifier: AEJT_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEJT_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 504 438 No. of bytes in distributed program, including test data, etc.: 14 448 180 Distribution format: tar.gz Programming language: Fortran 77 Computer: Any Operating system: Linux, MacOs RAM: Bytes Classification: 7.2 External routines: Lapack ( http://www.netlib.org/lapack/) Nature of problem: Calculation of the cross-section of various spectroscopies. Solution method: Multiple scattering. Running time: The test runs provided only take a few seconds to run.

  6. Insights into tidal disruption of stars from PS1-10jh

    NASA Astrophysics Data System (ADS)

    Strubbe, Linda E.; Murray, Norman

    2015-12-01

    Was PS1-10jh, an optical/ultraviolet transient discovered by the Pan-STARRS Medium Deep Survey, the tidal disruption of a star by a massive black hole (BH)? We address two aspects of the problem: the composition of the putative disrupted object (using the spectroscopic data), and the energetics of the observed gas and radiation (using the photometric data). We perform photoionization calculations and compare with the observed lower limit of the line ratio L_{He II 4686}/L_{Hα }>5 to argue that this event was not the disruption of a solar-type star, and instead was likely the disruption of a helium core (as first proposed by Gezari et al.). Disruption of such a dense object requires a relatively small central BH, MBH ≲ 2 × 105 M⊙. We use the photometric data to infer that PS1-10jh comprised an outflow of ˜0.01 M⊙ of gas, escaping from the BH at ˜1000 km s-1, and we propose that this outflow was driven primarily by radiation pressure trapped by Thomson and resonance line scattering. The large ratio of radiated energy to kinetic energy, Erad/EK ˜ 104, together with the large value of Erad ˜ 2 × 1051 erg, suggests that the outflow was shocked at large radius (perhaps similar to superluminous supernovae or the internal shock model for gamma-ray bursts). We describe puzzles in the physics of PS1-10jh, and discuss how this event may help us understand future tidal disruptions and super-Eddington accretion events as well.

  7. SU-E-T-327: Dosimetric Impact of Beam Energy for Intrabeam Breast IORT with Different Residual Cancer Cell Distributions After Surgery

    SciTech Connect

    Schwid, M; Zhang, H

    2015-06-15

    Purpose: The purpose of this study was to evaluate the dosimetric impact of beam energy to the IORT treatment of residual cancer cells with different cancer cell distributions after breast-conserving surgery. Methods: The three dimensional (3D) radiation doses of IORT using a 4-cm spherical applicator at the energy of 40 keV and 50 keV were separately calculated at different depths of the postsurgical tumor bed. The modified linear quadratic model (MLQ) was used to estimate the radiobiological response of the tumor cells assuming different radio-sensitivities and density distributions. The impact of radiation was evaluated for two types of breast cancer cell lines (α /β=10, and α /β =3.8) at 20 Gy dose prescribed at the applicator surface. Cancer cell distributions in the postsurgical tissue field were assumed to be a Gaussian with the standard deviations of 0.5, 1 and 2 mm respectively, namely the cancer cell infiltrations of 1.5, 3, and 6 mm respectively. The surface cancer cell percentage was assumed to be 0.01%, 0.1%, 1% and 10% separately. The equivalent uniform doses (EUD) for all the scenarios were calculated. Results: The EUDs were found to be dependent on the distributions of cancer cells, but independent of the cancer cell radio-sensitivities and the density at the surface. EUDs of 50 keV are 1% larger than that of 40 keV. For a prescription dose of 20 Gy, EUDs of 50 keV beam are 17.52, 16.21 and 13.14 Gy respectively for 0.5, 1.0 and 2.0 mm of the standard deviation of cancer cell Gaussian distributions. Conclusion: The impact by selected energies of IORT beams is very minimal. When energy is changed from 50 keV to 40 keV, the EUDs are almost the same for the same cancer cell distribution. 40 keV can be safely used as an alternative of 50 keV beam in IORT.

  8. Characterizations of MCP performance in the hard x-ray range (6–25 keV)

    SciTech Connect

    Wu, Ming Rochau, Greg; Moy, Ken; Kruschwitz, Craig

    2014-11-15

    MCP detector performance at hard x-ray energies from 6 to 25 keV was recently investigated using NSLS beamline X15A at BNL. Measurements were made with an NSTec Gen-II (H-CA-65) framing camera, based on a Photonis MCP with ∼10 μm in diameter pores, ∼12 μm center-center spacing, an L/D ratio of 46, and a bias angle of 8°. The MCP characterizations were focused on (1) energy and angle dependent sensitivity, (2) energy and angle dependent spatial resolution, (3) energy dependent gain performance, and (4) energy dependent dynamic range. These measurement corroborated simulation results using a Monte Carlo model that included hard x-ray interactions and the subsequent electron cascade in the MCP.

  9. Searching for the 3.5 keV Line in the Stacked Suzaku Observations of Galaxy Clusters

    NASA Astrophysics Data System (ADS)

    Bulbul, Esra; Markevitch, Maxim; Foster, Adam; Miller, Eric; Bautz, Mark; Loewenstein, Mike; Randall, Scott W.; Smith, Randall K.

    2016-11-01

    We perform a detailed study of the stacked Suzaku observations of 47 galaxy clusters, spanning a redshift range of 0.01-0.45, to search for the unidentified 3.5 keV line. This sample provides an independent test for the previously detected line. We detect a 2σ -significant spectral feature at 3.5 keV in the spectrum of the full sample. When the sample is divided into two subsamples (cool-core and non-cool core clusters), the cool-core subsample shows no statistically significant positive residuals at the line energy. A very weak (˜ 2σ confidence) spectral feature at 3.5 keV is permitted by the data from the non-cool-core clusters sample. The upper limit on a neutrino decay mixing angle of {\\sin }2(2θ )=6.1× {10}-11 from the full Suzaku sample is consistent with the previous detections in the stacked XMM-Newton sample of galaxy clusters (which had a higher statistical sensitivity to faint lines), M31, and Galactic center, at a 90% confidence level. However, the constraint from the present sample, which does not include the Perseus cluster, is in tension with previously reported line flux observed in the core of the Perseus cluster with XMM-Newton and Suzaku.

  10. Sub-arcsec X-Ray Telescope for Imaging The Solar Corona In the 0.25 - 1.2 keV Band

    NASA Technical Reports Server (NTRS)

    Gallagher, Dennis; Cash, Webster; Jelsma, Schuyler; Farmer, Jason

    1996-01-01

    We have developed an X-ray telescope that uses a new technique for focusing X-rays with grazing incidence optics. The telescope was built with spherical optics for all of its components, utilizing the high quality surfaces obtainable when polishing spherical (as opposed to aspherical) optics. We tested the prototype X-ray telescope in the 300 meter vacuum pipe at White Sands Missile Range, NM. The telescope features 2 degee graze angles with tungsten coatings, yielding a bandpass of 0.25-1.5 keV with a peak effective area of 0.8 sq cm at 0.83 keV. Results from X-ray testing at energies of 0.25 keV and 0.93 keV (C-K and Cu-L) verify 0.5 arcsecond performance at 0.93 keV. Results from modeling the X-ray telescope's response to the Sun show that the current design would be capable of recording 10 half arcsecond images of a solar active region during a 300 second NASA sounding rocket flight.

  11. CAN THE EXCESS IN THE Fe XXVI Ly{gamma} LINE FROM THE GALACTIC CENTER PROVIDE EVIDENCE FOR 17 keV STERILE NEUTRINOS?

    SciTech Connect

    Prokhorov, Dmitry; Silk, Joseph

    2010-12-20

    Sterile neutrinos (or right-handed neutrinos) are a plausible warm dark matter candidate. We find that the excess of the intensity in the 8.7 keV line (at the energy of the Fe XXVI Ly{gamma} line) in the spectrum of the Galactic center observed by Suzaku cannot be explained by standard ionization and recombination processes. We suggest that the origin of this excess is via decays of sterile neutrinos with a mass of 17.4 keV. The estimated value of the mixing angle sin{sup 2}(2{theta}) = (4.4 {+-} 2.2) x 10{sup -12} lies in the allowed region of the mixing angle for a dark matter sterile neutrino with a mass of 17-18 keV.

  12. Characterization and cross calibration of Agfa D4, D7, and D8 and Kodak SR45 x-ray films against direct exposure film at 4.0-5.5 keV

    SciTech Connect

    Lanier, N.E.; Cowan, J.S.; Workman, J.

    2006-04-15

    Kodak direct exposure film (DEF) [B. L. Henke et al., J. Opt. Soc. Am. B 3, 1540 (1986)] has been the standard for moderate energy (1-10 keV) x-ray diagnostic applications among the high-energy-density and inertial confinement fusion research communities. However, market forces have prompted Kodak to discontinue production of DEF, leaving these specialized communities searching for a replacement. We have conducted cross-calibration experiments and film characterizations on five possible substitutes for Kodak DEF. The film types studied were Kodak's Biomax MR (BMR) and SR45 along with Agfa's D8, D7, and D4sc. None of the films tested matched the speed of DEF. BMR and D8 were closest but D8 exhibited lower noise, with superior resolution and dynamic range. Agfa D7, Agfa D4sc, and Kodak SR45 were significantly less sensitive than BMR and D8, however, the improvements they yielded in resolution and dynamic range warrant their use if experimental constraints allow.

  13. Characterization and cross calibration of Agfa D4, D7, and D8 and Kodak SR45 x-ray films against direct exposure film at 4.0-5.5 keV

    NASA Astrophysics Data System (ADS)

    Lanier, N. E.; Cowan, J. S.; Workman, J.

    2006-04-01

    Kodak direct exposure film (DEF) [B. L. Henke et al., J. Opt. Soc. Am. B 3, 1540 (1986)] has been the standard for moderate energy (1-10keV) x-ray diagnostic applications among the high-energy-density and inertial confinement fusion research communities. However, market forces have prompted Kodak to discontinue production of DEF, leaving these specialized communities searching for a replacement. We have conducted cross-calibration experiments and film characterizations on five possible substitutes for Kodak DEF. The film types studied were Kodak's Biomax MR (BMR) and SR45 along with Agfa's D8, D7, and D4sc. None of the films tested matched the speed of DEF. BMR and D8 were closest but D8 exhibited lower noise, with superior resolution and dynamic range. Agfa D7, Agfa D4sc, and Kodak SR45 were significantly less sensitive than BMR and D8, however, the improvements they yielded in resolution and dynamic range warrant their use if experimental constraints allow.

  14. Ionization and fragmentation of polycyclic aromatic hydrocarbon clusters in collisions with keV ions

    SciTech Connect

    Johansson, H. A. B.; Zettergren, H.; Holm, A. I. S.; Seitz, F.; Schmidt, H. T.; Cederquist, H.; Rousseau, P.; Lawicki, A.; Capron, M.; Domaracka, A.; Lattouf, E.; Maclot, S.; Maisonny, R.; Chesnel, J.-Y.; Adoui, L.; Huber, B. A.

    2011-10-15

    We report on an experimental study of the ionization and fragmentation of clusters of k polycyclic aromatic hydrocarbon (PAH) molecules using anthracene, C{sub 14}H{sub 10}, or coronene, C{sub 24}H{sub 12}. These PAH clusters are moderately charged and strongly heated in small impact parameter collisions with 22.5-keV He{sup 2+} ions, after which they mostly decay in long monomer evaporation sequences with singly charged and comparatively cold monomers as dominating end products. We describe a simple cluster evaporation model and estimate the number of PAH molecules in the clusters that have to be hit by He{sup 2+} projectiles for such complete cluster evaporations to occur. Highly charged and initially cold clusters are efficiently formed in collisions with 360-keV Xe{sup 20+} ions, leading to cluster Coulomb explosions and several hot charged fragments, which again predominantly yield singly charged, but much hotter, monomer ions than the He{sup 2+} collisions. We present a simple formula, based on density-functional-theory calculations, for the ionization energy sequences as functions of coronene cluster size, rationalized in terms of the classic electrostatic expression for the ionization of a charged conducting object. Our analysis indicates that multiple electron removal by highly charged ions from a cluster of PAH molecules rapidly may become more important than single ionization as the cluster size k increases and that this is the main reason for the unexpectedly strong heating in these types of collisions.

  15. Black-hole Binaries: Life Begins at 40 keV

    NASA Astrophysics Data System (ADS)

    Belloni, Tomaso M.; Motta, Sara

    2009-05-01

    In the study of black-hole transients, an important problem that still needs to be answered is how the high-energy part of the spectrum evolves from the low-hard to the high-soft state, given that they have very different properties. Recent results obtained with RXTE and INTEGRAL have given inconsistent results. With RXTE, we have found that the high-energy cutoff in GX 339-4 during the transition first decreases (during the low-hard state), then increases again across the Hard-Intermediate state, to become unmeasurable in the soft states (possibly because of statistical limitations). We show Simbol-X will be able to determine the spectral shape with superb accuracy. As the high-energy part of the spectrum is relatively less known than the one below 20 keV, Simbol-X will provide important results that will help out understanding of the extreme physical conditions in the vicinity of a stellar-mass black hole.

  16. ART: Surveying the Local Universe at 2-11 keV

    NASA Technical Reports Server (NTRS)

    O'Dell, S. L.; Ramsey, B. D.; Adams, M. L.; Brandt, W. N.; Bubarev, M. V.; Hassinger, G.; Pravlinski, M.; Predehl, P.; Romaine, S. E.; Swartz, D. A.; Urry, C. M.; Vikhlinin, A.; Weisskopf, M. C.

    2008-01-01

    The Astronomical Rontgen Telescope (ART) is a medium-energy x-ray telescope system proposed for the Russian-led mission Spectrum Rontgen-Gamma (SRG). Optimized for performance over the 2-11-keV band, ART complements the softer response of the SRG prime instrument-the German eROSITA x-ray telescope system. The anticipated number of ART detections is 50,000-with 1,000 heavily-obscured (N(sub H)> 3x10(exp 23)/sq cm) AGN-in the SRG 4-year all-sky survey, plus a comparable number in deeper wide-field (500 deg(sup 2) total) surveys. ART's surveys will provide a minimally-biased, nearly-complete census of the local Universe in the medium-energy x-ray band (including Fe-K lines), at CCD spectral resolution. During long (approx.100-ks) pointed observations, ART can obtain statistically significant spectral data up to about 15 keY for bright sources and medium-energy x-ray continuum and Fe-K-line spectra of AGN detected with the contemporaneous NuSTAR hard-x-ray mission.

  17. Electron capture and excitation in collisions of O[sup +]([sup 4][ital S],[sup 2][ital D],[sup 2][ital P]) ions with He atoms and He[sup +] ions with O atoms at energies below 10 keV

    SciTech Connect

    Kimura, M. Department of Physics, Rice University, Houston, Texas 77251 ); Gu, J.P.; Liebermann, H.P.; Li, Y.; Hirsch, G.; Buenker, R.J. ); Dalgarno, A. )

    1994-12-01

    Electron capture and excitation in O[sup +]([sup 4][ital S],[sup 2][ital D],[sup 2][ital P])+He collisions above 100 eV are studied theoretically by using a semiclassical molecular representation and electron capture in He[sup +]+O([sup 3][ital P]) collisions; excitation and deexcitation in O[sup +]([sup 4][ital S])+He[leftrightarrow]O[sup +]([sup 2][ital D])+He collisions at lower energies are studied by using a fully-quantum-mechanical molecular representation. At higher energies, nonadiabatic couplings are the driving forces that cause transitions. At collision energies below 10 eV, transitions are driven by spin-orbit couplings. At kilo-electron-volt energies, the contribution from metastable O[sup +]([sup 2][ital D],[sup 2][ital P]) ions to electron capture is much larger than that from the ground O[sup +]([sup 4][ital S]) ions. At energies below 1 eV, the cross section for electron capture in He[sup +]+O collisions is very small, with a magnitude of less than 10[sup [minus]20] cm[sup 2]. The cross sections for the excitation-deexcitation of metastable O[sup +] ions are larger, with values near 10[sup [minus]18] cm[sup 2].

  18. Packaged HVAC Unit Diagnostician version 1.0

    SciTech Connect

    2007-01-09

    The PHD automatically detects and diagnoses faults with respect to four major aspects of packaged heating, ventilating, and air conditioning (HVAC) unit operation: 1) air handling in which return-air and outdoor-air are mixed, then conditioned to appropriate temperature and humidity conditions, 2) vapor-compression refrigerant loop operation, 3) overall unit efficiency and its potential degradation over time, and 4) operation scheduling. When faults are detected, the software provides alarm codes corresponding to the detected problem(s). These alarms map into explanations of the faults, possible causes for them, and suggested actions to remedy the faults. For air handling, the software also estimates energy and cost impacts of faults. The software is intended for implementation on a hardware systems that includes sensors, sensor signal processing, micro-processor unit for running this software, and communication to a web server. Results are made available to users via the world wide web using a computer with Web browser and Internet connection for access. The graphical web-based interface must be provided by an application service provider (not part of this software).

  19. Sandia Hyperspectral Upper-Bound Spectrum Version 1.0

    SciTech Connect

    Anthony, Stephen

    2016-04-15

    The Sandia hyperspectral upper-bound spectrum algorithm (hyper-UBS) is a cosmic ray despiking algorithm for hyperspectral data sets. When naturally-occurring, high-energy (gigaelectronvolt) cosmic rays impact the earth’s atmosphere, they create an avalanche of secondary particles which will register as a large, positive spike on any spectroscopic detector they hit. Cosmic ray spikes are therefore an unavoidable spectroscopic contaminant which can interfere with subsequent analysis. A variety of cosmic ray despiking algorithms already exist and can potentially be applied to hyperspectral data matrices, most notably the upper-bound spectrum data matrices (UBS-DM) algorithm by Dongmao Zhang and Dor Ben-Amotz which served as the basis for the hyper-UBS algorithm. However, the existing algorithms either cannot be applied to hyperspectral data, require information that is not always available, introduce undesired spectral bias, or have otherwise limited effectiveness for some experimentally relevant conditions. Hyper-UBS is more effective at removing a wider variety of cosmic ray spikes from hyperspectral data without introducing undesired spectral bias. In addition to the core algorithm the Sandia hyper-UBS software package includes additional source code useful in evaluating the effectiveness of the hyper-UBS algorithm. The accompanying source code includes code to generate simulated hyperspectral data contaminated by cosmic ray spikes, several existing despiking algorithms, and code to evaluate the performance of the despiking algorithms on simulated data.

  20. The Physical Nature of the Sharp Spectral Feature at 7 keV Detected in 1H0707-495

    NASA Technical Reports Server (NTRS)

    Brandt, Niel

    2005-01-01

    XMM-Newton acquired data on the accepted target, 1H0707-495, on 2002 October 13 during revolution 0521. The observation was successful, with only about 5% data loss due to background flaring. We compared the data from this observation with earlier data taken on this Narrow-Line Seyfert 1 about two years before, performing interpretation studies in the context of the partial-covering model. Our second longer observation once again displays a sharp (< 200 eV) spectral drop above 7 keV. However, in comparison to the first observation, the edge depth and energy have changed significantly. In addition to changes in the edge parameters, the high-energy spectrum appears steeper. The changes in the high-energy spectrum can be adequately explained in terms of a partial-covering absorber out-flowing from the central region. The low-energy spectrum also shows significant long-term spectral variability, including (1) a substantial increase in the disk temperature, (2) detection of an approx. 0.9 keV emission feature, and (3) the presence of ionized absorption that was detected during the ASCA mission. The large increase in disk temperature, and the more modest rise in luminosity, can be understood if we consider a slim-disk model for 1H0707-495. In addition, the higher disk luminosity could be the driving force behind the outflow and the re-appearance of an ionized medium during the second XMM-Newton observation.

  1. Impact of IUdR on Rat 9L glioma cell survival for 25-35 keV photon-activated auger electron therapy.

    PubMed

    Alvarez, Diane; Hogstrom, Kenneth R; Brown, Thomas A D; Ii, Kenneth L Matthews; Dugas, Joseph P; Ham, Kyungmin; Varnes, Marie E

    2014-12-01

    The goal of the current study was to measure the energy dependence of survival of rat 9L glioma cells labeled with iododeoxyuridine (IUdR) that underwent photon-activated Auger electron therapy using 25-35 keV monochromatic X rays, i.e., above and below the K-edge energy of iodine. Rat 9L glioma cells were selected because of their radioresistance, ability to be implanted for future in vivo studies and analogy to radioresistant human gliomas. Survival curves were measured for a 4 MV X-ray beam and synchrotron produced monochromatic 35, 30 and 25 keV X-ray beams. IUdR was incorporated into the DNA at levels of 0, 9 and 18% thymidine replacement for 4 MV and 35 keV and 0 and 18% thymidine replacement for 30 and 25 keV. For 10 combinations of beam energy and thymidine replacement, 62 data sets (3-13 per combination) provided 776 data points (47-148 per combination). Survival versus dose data taken for the same combination, but on different days, were merged by including the zero-dose points in the nonlinear, chi-squared data fitting using the linear-quadratic model and letting the best estimate to the zero-dose plating efficiency for each of the different days be a fitting parameter. When comparing two survival curves, the ratio of doses resulting in 10% survival gave sensitization enhancement ratios (SER10) from which contributions due to linear energy transfer (LET) (SER10,LET), IUdR radiosensitization (SER10,RS), the Auger effect (SER10,AE) and the total of all effects (SER10,T) were determined. At 4 MV and 35, 30 and 25 keV, SER10,LET values were 1.00, 1.08 ± 0.03, 1.22 ± 0.02 and 1.37 ± 0.02, respectively. At 4 MV SER10,RS values for 9 and 18% IUdR were 1.28 ± 0.02 and 1.40 ± 0.02, respectively. Assuming LET effects were independent of percentage IUdR and radiosensitization effects were independent of energy, SER10,AE values for 18% IUdR at 35, 30 and 25 keV were 1.35 ± 0.05, 1.06 ± 0.03 and 0.98 ± 0.03, respectively. The value for 9% IUdR at 35 keV was 1

  2. QUIET-TIME SUPRATHERMAL (∼0.1–1.5 keV) ELECTRONS IN THE SOLAR WIND

    SciTech Connect

    Tao, Jiawei; Wang, Linghua; Zong, Qiugang; He, Jiansen; Tu, Chuanyi; Li, Gang; Salem, Chadi S.; Bale, Stuart D.; Wimmer-Schweingruber, Robert F.

    2016-03-20

    We present a statistical survey of the energy spectrum of solar wind suprathermal (∼0.1–1.5 keV) electrons measured by the WIND 3DP instrument at 1 AU during quiet times at the minimum and maximum of solar cycles 23 and 24. After separating (beaming) strahl electrons from (isotropic) halo electrons according to their different behaviors in the angular distribution, we fit the observed energy spectrum of both strahl and halo electrons at ∼0.1–1.5 keV to a Kappa distribution function with an index κ and effective temperature T{sub eff}. We also calculate the number density n and average energy E{sub avg} of strahl and halo electrons by integrating the electron measurements between ∼0.1 and 1.5 keV. We find a strong positive correlation between κ and T{sub eff} for both strahl and halo electrons, and a strong positive correlation between the strahl n and halo n, likely reflecting the nature of the generation of these suprathermal electrons. In both solar cycles, κ is larger at solar minimum than at solar maximum for both strahl and halo electrons. The halo κ is generally smaller than the strahl κ (except during the solar minimum of cycle 23). The strahl n is larger at solar maximum, but the halo n shows no difference between solar minimum and maximum. Both the strahl n and halo n have no clear association with the solar wind core population, but the density ratio between the strahl and halo roughly anti-correlates (correlates) with the solar wind density (velocity)

  3. Atomic, Molecular, and Optical Physics: Optical Excitation Function of H(1s-2p) Produced by electron Impact from Threshold to 1.8 keV

    NASA Technical Reports Server (NTRS)

    James, G. K.; Slevin, J. A.; Shemansky, D. E.; McConkey, J. W.; Bray, I.; Dziczek, D.; Kanik, I.; Ajello, J. M.

    1997-01-01

    The optical excitation function of prompt Lyman-Alpha radiation, produced by electron impact on atomic hydrogen, has been measured over the extended energy range from threshold to 1.8 keV. Measurements were obtained in a crossed-beams experiment using both magnetically confined and electrostatically focused electrons in collision with atomic hydrogen produced by an intense discharge source. A vacuum-ultraviolet mono- chromator system was used to measure the emitted Lyman-Alpha radiation. The absolute H(1s-2p) electron impact excitation cross section was obtained from the experimental optical excitation function by normalizing to the accepted optical oscillator strength, with corrections for polarization and cascade. Statistical and known systematic uncertainties in our data range from +/- 4% near threshold to +/- 2% at 1.8 keV. Multistate coupling affecting the shape of the excitation function up to 1 keV impact energy is apparent in both the present experimental data and present theoretical results obtained with convergent close- coupling (CCC) theory. This shape function effect leads to an uncertainty in absolute cross sections at the 10% level in the analysis of the experimental data. The derived optimized absolute cross sections are within 7% of the CCC calculations over the 14 eV-1.8 keV range. The present CCC calculations converge on the Bethe- Fano profile for H(1s-2p) excitation at high energy. For this reason agreement with the CCC values to within 3% is achieved in a nonoptimal normalization of the experimental data to the Bethe-Fano profile. The fundamental H(1s-2p) electron impact cross section is thereby determined to an unprecedented accuracy over the 14 eV - 1.8 keV energy range.

  4. Search for a 17 keV neutrino in the internal bremsstrahlung spectrum of 125I

    NASA Astrophysics Data System (ADS)

    Hindi, M. M.; Kozub, R. L.; Robinson, S. J.

    1994-06-01

    We have searched for evidence of the emission of a 17 keV neutrino in the internal bremsstrahlung (IB) spectrum accompanying the electron capture decay of 125I. The IB spectrum, recorded in a planar Ge detector, has 1.2×106 counts per keV at 17 keV below the 2p end point. We set an upper limit of 0.4% for the admixture of a 17 keV neutrino, at the 90% confidence level, and exclude a 0.8% admixture at the 99.6% confidence level. The QEC value is found to be 185.77+/-0.06 keV. We also find that the recent calculations of Surić et al., which employ relativistic self-consistent-field atomic wave functions, reproduce the shape and relative intensity of IB partial spectra within a few percent.

  5. Frequency analysis of 4- to 6-keV electrons associated with an auroral arc

    NASA Technical Reports Server (NTRS)

    Murphree, J. S.; Anderson, H. R.

    1978-01-01

    The high time resolution (HTR) experiment considered consists of four sections, including electrostatic deflection plates, electron multiplier, preamplifier-integrator, and frequency analyzer. Electrons in the energy range from 4 to 6 keV electrons are selected by the deflection system, after which they are detected, multiplied, and passed to the charge sensitive preamplifier. The charge pulses are amplified and integrated, and the resulting voltage pulse series is fed to the frequency analyzer. The experiment is essentially a flux detector, so that estimates of the input flux can be made from the mean value of the output spectrum. The results obtained with the HTR in a rocket flight on March 14, 1974, are discussed. The lack of modulation noticed in the high-frequency range indicates that there is insufficient wave energy available in the vicinity of the rocket to produce a wave-particle interaction which the HTR is able to observe. This finding is consistent with the stabilization of the plasma by the low flux of energetic electrons.

  6. High-efficiency multilevel zone plates for keV X-rays

    NASA Astrophysics Data System (ADS)

    di Fabrizio, E.; Romanato, F.; Gentili, M.; Cabrini, S.; Kaulich, B.; Susini, J.; Barrett, R.

    1999-10-01

    The development of high brilliance X-ray sources coupled with advances in manufacturing technologies has led to significant improvements in submicrometre probes for spectroscopy, diffraction and imaging applications. The generation of a small beam spot size is commonly based on three principles: total reflection (as used in optical elements involving mirrors or capillaries), refraction (such as in refractive lenses) and diffraction. The latter effect is employed in Bragg-Fresnel or Soret lenses, commonly known as Fresnel zone plate lenses. These lenses currently give the best spatial resolution, but are traditionally limited to rather soft X-rays-at high energies, their use is still limited by their efficiency. Here we report the fabrication of high-efficiency, high-contrast gold and nickel multistep (quaternary) Fresnel zone plates using electron beam lithography. We achieve a maximum efficiency of 55% for the nickel plate at 7keV. In addition to their high efficiency, the lenses offer the advantages of low background signal and effective reduction of unwanted diffraction orders. We anticipate that these lenses should have a significant impact on techniques such as microscopy, micro-fluorescence and micro-diffraction, which require medium resolution (500-100nm) and high flux at fixed energies.

  7. Silicon photodiode characterization from 1 eV to 10 keV

    SciTech Connect

    Idzorek, G.C.; Bartlett, R.J.

    1997-10-01

    Silicon photodiodes offer a number of advantages over conventional photocathode type soft x-ray detectors in pulsed power experiments. These include a nominally flat response, insensitivity to surface contamination, low voltage biasing requirements, sensitivity to low energy photons, excellent detector to detector response reproducibility, and ability to operate in poor vacuum or gas backfilled experiments. Silicon photodiodes available from International Radiation Detectors (IRD), Torrance, California have been characterized for absolute photon response from 1 eV to 10 keV photon energy, time response, and signal saturation levels. The authors have assembled individually filtered photodiodes into an array designated the XUV-7. The XUV-7 provides seven photodiodes in a vacuum leak tight, electrically isolated, low noise, high bandwidth, x-ray filtered assembly in a compact package with a 3.7 cm outside diameter. In addition they have assembled the diodes in other custom configurations as detectors for spectrometers. Their calibration measurements show factor of ten deviations from the silicon photodiode theoretical flat response due to diode sensitivity outside the center `sensitive area`. Detector response reproducibility between diodes appears to be better than 5%. Time response measurements show a 10-90% rise time of about 0.1 nanoseconds and a fall time of about 0.5 nanoseconds. Silicon photodiodes have proven to be a versatile and useful complement to the standard photocathode detectors for soft x-ray measurement and are very competitive with diamond for a number of applications.

  8. ENHANCEMENT OF THE 6.4 keV LINE IN THE INNER GALACTIC RIDGE: PROTON-INDUCED FLUORESCENCE?

    SciTech Connect

    Nobukawa, K. K.; Nobukawa, M.; Tsuru, T. G.; Tanaka, T.; Koyama, K.; Uchiyama, H.; Torii, K.; Fukui, Y.; Chernyshov, D. O.; Dogiel, V. A.

    2015-07-01

    A common idea for the origin of the Galactic diffuse X-ray emission, particularly that of the iron lines from neutral and highly ionized atoms, is a superposition of many cataclysmic variables and coronally active binaries. In this scenario, the flux should symmetrically distribute between the east and west on the plane with respect to Sagittarius A* because the stellar mass distribution determined by infrared observations is nearly symmetric. This symmetry is confirmed for the highly ionized iron line as well as the continuum emission. However, a clear excess of the neutral iron line in the near east of the Galactic center compared to the near-west side is found. The flux distribution of the excess emission well correlates with the molecular column density. The X-ray spectrum of the excess emission is described by a power-law continuum plus a 6.4 keV line with a large equivalent width of ∼1.3 keV, which is hardly explained by the low-energy electron bombardment scenario. The longitudinal and latitudinal distribution of the excess emission disfavors the X-ray irradiation, either by Sagittarius A* or by nearby X-ray binaries. Then, the low-energy proton bombardment is the most probable origin, although the high-energy density ∼80 eV cm{sup −3} in 0.1–1000 MeV is required and there is no conventional proton source in the vicinity.

  9. Institut d'Astrophysique Spatiale (IAS) 0.1- to 15-keV Synchrotron Radiation Facility beam lines

    NASA Astrophysics Data System (ADS)

    Dhez, Pierre; Jourdain, Erick; Hainaut, Olivier; Hochedez, Jean-Francois E.; Labeque, Alain; Salvetat, Philippe; Song, Xue Yan

    1997-10-01

    Two beam lines have been built at the Institute d'Astrophysique Spatiale (IAS) d'Orsay to perform absolute calibration of the EPIC (European photon imaging camera). EPIC consists of three x-ray charge coupled device (CCD) cameras having imaging and spectroscopic performances set at the Wolter telescope focal planes on board the x-ray multi mirror mission (XMM) planned to be launched by ESA in August 1999. To cover the desired 0.1 - 15 keV range a dedicated beam line has been built on each synchrotron sources of the Laboratoire pour l'Utilisation du Rayonnement Synchrotron (LURE): SACO (0.8 GeV) and DCI (1.5 GeV). Both beam lines are merging in a clean 23 m(superscript 3) vacuum tank containing the camera to calibrate. (1) The SACO windowless beam line is equipped with a grating monochromator. Four plane VLS gratings are used to cover the low energy range (0.1 - 1.2 keV). A triple grazing incidence mirror system set in front of the entrance slit removes the overlapping orders. (2) The high energy beam line on DCI has a 50 micrometer beryllium window and a double flat crystals monochromator equipped with four different crystal pairs. A double grazing incidence mirror system set close to the source absorbs the high energy photon spectra. CCD calibrations will be performed during 1997 second semester and years 1998.

  10. Enhancement of the 6.4 keV Line in the Inner Galactic Ridge: Proton-induced Fluorescence?

    NASA Astrophysics Data System (ADS)

    Nobukawa, K. K.; Nobukawa, M.; Uchiyama, H.; Tsuru, T. G.; Torii, K.; Tanaka, T.; Chernyshov, D. O.; Fukui, Y.; Dogiel, V. A.; Koyama, K.

    2015-07-01

    A common idea for the origin of the Galactic diffuse X-ray emission, particularly that of the iron lines from neutral and highly ionized atoms, is a superposition of many cataclysmic variables and coronally active binaries. In this scenario, the flux should symmetrically distribute between the east and west on the plane with respect to Sagittarius A* because the stellar mass distribution determined by infrared observations is nearly symmetric. This symmetry is confirmed for the highly ionized iron line as well as the continuum emission. However, a clear excess of the neutral iron line in the near east of the Galactic center compared to the near-west side is found. The flux distribution of the excess emission well correlates with the molecular column density. The X-ray spectrum of the excess emission is described by a power-law continuum plus a 6.4 keV line with a large equivalent width of ˜1.3 keV, which is hardly explained by the low-energy electron bombardment scenario. The longitudinal and latitudinal distribution of the excess emission disfavors the X-ray irradiation, either by Sagittarius A* or by nearby X-ray binaries. Then, the low-energy proton bombardment is the most probable origin, although the high-energy density ˜80 eV cm-3 in 0.1-1000 MeV is required and there is no conventional proton source in the vicinity.

  11. Observations and Light Curve Solutions of the Eclipsing Binaries USNO-B1.0 1395-0370184 and USNO-B1.0 1395-0370731

    NASA Astrophysics Data System (ADS)

    Kjurkchieva, D.; Popov, V. A.; Vasileva, D.; Petrov, N.

    2016-12-01

    We present follow-up photometric observations in Sloan filters g', i' of the newly discovered eclipsing stars USNO-B1.0 1395-0370184 and USNO-B1.0 1395-0370731. Our data revealed that their orbital periods are considerably bigger than the previous values. This result changed the classification of USNO-B1.0 1395-0370184 from ultrashort-period binary (P=0.197 d) to short-period system (P=0.251 d). The light curve solutions of our observations revealed that USNO-B1.0 1395-0370184 and USNO-B1.0 1395-0370731 are overcontact binaries in which components are K dwarfs, close in masses and radii. The light curve distortions were reproduced by cool spots with angular radius of around 20°.

  12. A national FFQ for the Netherlands (the FFQ-NL 1.0): validation of a comprehensive FFQ for adults.

    PubMed

    Sluik, Diewertje; Geelen, Anouk; de Vries, Jeanne H M; Eussen, Simone J P M; Brants, Henny A M; Meijboom, Saskia; van Dongen, Martien C J M; Bueno-de-Mesquita, H Bas; Wijckmans-Duysens, Nicole E G; van 't Veer, Pieter; Dagnelie, Pieter C; Ocké, Marga C; Feskens, Edith J M

    2016-09-01

    A standardised, national, 160-item FFQ, the FFQ-NL 1.0, was recently developed for Dutch epidemiological studies. The objective was to validate the FFQ-NL 1.0 against multiple 24-h recalls (24hR) and recovery and concentration biomarkers. The FFQ-NL 1.0 was filled out by 383 participants (25-69 years) from the Nutrition Questionnaires plus study. For each participant, one to two urinary and blood samples and one to five (mean 2·7) telephone-based 24hR were available. Group-level bias, correlation coefficients, attenuation factors, de-attenuated correlation coefficients and ranking agreement were assessed. Compared with the 24hR, the FFQ-NL 1.0 estimated the intake of energy and macronutrients well. However, it underestimated intakes of SFA and trans-fatty acids and alcohol and overestimated intakes of most vitamins by >5 %. The median correlation coefficient was 0·39 for energy and macronutrients, 0·30 for micronutrients and 0·30 for food groups. The FFQ underestimated protein intake by an average of 16 % and K by 5 %, relative to their urinary recovery biomarkers. Attenuation factors were 0·44 and 0·46 for protein and K, respectively. Correlation coefficients were 0·43-0·47 between (fatty) fish intake and plasma EPA and DHA and 0·24-0·43 between fruit and vegetable intakes and plasma carotenoids. In conclusion, the overall validity of the newly developed FFQ-NL 1.0 was acceptable to good. The FFQ-NL 1.0 is well suited for future use within Dutch cohort studies among adults.

  13. Hardening of the surface layers of commercial pure titanium VT1-0 under combined treatment

    NASA Astrophysics Data System (ADS)

    Bashchenko, Lyudmila P.; Gromov, Viktor E.; Budovskikh, Evgenii A.; Ivanov, Yurii F.; Soskova, Nina A.

    2015-10-01

    The treatment of VT1-0 titanium samples was carried out by concentrated energy fluxes. The combined treatment included surface carburizing with the joint use of powder samples of compounds with high physical and mechanical properties (namely, titanium diboride TiB2, silicon carbide SiC and zirconium oxide ZrO2) and subsequent electron beam treatment of surface layers formed in electroexplosive treatment. The combined treatment of surface layers resulted in the multifold increase in microhardness, which reduces depending on the depth of hardening zone. After electron-beam treatment, the depth of hardening zone is increased. During electron-beam treatment, the two-layer hardening zone forms.

  14. GridLAB-D Technical Support Document: Residential End-Use Module Version 1.0

    SciTech Connect

    Taylor, Zachary T.; Gowri, Krishnan; Katipamula, Srinivas

    2008-07-31

    1.0 Introduction The residential module implements the following end uses and characteristics to simulate the power demand in a single family home: • Water heater • Lights • Dishwasher • Range • Microwave • Refrigerator • Internal gains (plug loads) • House (heating/cooling loads) The house model considers the following four major heat gains/losses that contribute to the building heating/cooling load: 1. Conduction through exterior walls, roof and fenestration (based on envelope UA) 2. Air infiltration (based on specified air change rate) 3. Solar radiation (based on CLTD model and using tmy data) 4. Internal gains from lighting, people, equipment and other end use objects. The Equivalent Thermal Parameter (ETP) approach is used to model the residential loads and energy consumption. The following sections describe the modeling assumptions for each of the above end uses and the details of power demand calculations in the residential module.

  15. Hardening of the surface layers of commercial pure titanium VT1-0 under combined treatment

    SciTech Connect

    Bashchenko, Lyudmila P. Gromov, Viktor E. Budovskikh, Evgenii A. Soskova, Nina A.; Ivanov, Yurii F.

    2015-10-27

    The treatment of VT1-0 titanium samples was carried out by concentrated energy fluxes. The combined treatment included surface carburizing with the joint use of powder samples of compounds with high physical and mechanical properties (namely, titanium diboride TiB{sub 2}, silicon carbide SiC and zirconium oxide ZrO{sub 2}) and subsequent electron beam treatment of surface layers formed in electroexplosive treatment. The combined treatment of surface layers resulted in the multifold increase in microhardness, which reduces depending on the depth of hardening zone. After electron-beam treatment, the depth of hardening zone is increased. During electron-beam treatment, the two-layer hardening zone forms.

  16. Calculations of stopping powers and inelastic mean free paths for 20 eV-20 keV electrons in 11 types of human tissue.

    PubMed

    Tan, Zhenyu; Liu, Wei

    2013-12-01

    Systematic calculations are performed for determining the stopping powers (SP) and inelastic mean free paths (IMFP) for 20 eV-20 keV electrons in 11 types of human tissue. The calculations are based on a dielectric model, including the Born-Ochkur exchange correction. The optical energy loss functions (OELF) are empirically evaluated, because of the lack of available experimental optical data for the 11 tissues under consideration. The evaluated OELFs are examined by the f-sum rule expected from the dielectric response theory, and by calculation of the mean excitation energy. The calculated SPs are compared with those for PMMA (polymethylmethacrylate, a tissue equivalent material) and liquid water. The SP and IMFP data presented here are the results for the 11 human tissues over the energy range of 20 eV-20 keV, and are of importance in radiotherapy planning and for studies of various radiation effects on human tissues.

  17. Die chemische Fixierung von Kryptonisotopen in Zeolith 5 A — Voraussetzung für die Messung von 25 keV Neutroneneinfang- querschnitten mit der Aktivierungstechnik/ The Chemical Fixation of Kr Isotopes in Zeolite 5 A.- Prerequisite for the Determination of 25 keV Neutron Capture Cross Sections with the Activation Method

    NASA Astrophysics Data System (ADS)

    Penzhorn, R.-D.; Walter, G.; Beer, H.

    1983-07-01

    By chemical fixation of Kr in zeolite 5 A adequate samples can be obtained to determine the capture cross section of reactions such as 84 Kr (n, γ) 85Krm and 86Kr (n, γ) 87Kr. The employed zeolite loading was of the order 52-66 [cm3 STP Kr/g zeolite]. The capture cross section of the reaction 84Kr(n, γ) 85Krm was determined at thermal and 25 keV neutron energy. The value obtained at 25 keV is of relevance to the stellar nucleosynthesis of heavy elements.

  18. Electron impact total cross section calculations for CH3SH (methanethiol) from threshold to 5 keV

    NASA Astrophysics Data System (ADS)

    Limbachiya, Chetan; Vinodkumar, Minaxi; Swadia, Mohit; Barot, Avani

    2014-01-01

    We report calculated total elastic cross sections Qel, total ionisation cross sections, Qion, summed total excitation cross sections ∑Qexc and total cross sections QT for CH3SH upon electron impact for energies from ionisation threshold to 5 keV. We have employed Spherical Complex Optical Potential (SCOP) formalism to calculate total elastic cross section Qel, and total inelastic cross section Qinel and used Complex Scattering Potential - the ionisation contribution (CSP-ic) method to extract the ionisation cross sections, Qion, from the calculated Qinel. The calculated total cross sections are examined as functions of incident electron energy and are compared with available data wherever possible and overall good agreement is observed. In this work Qel, Qion, and ∑Qexc are reported for the first time for CH3SH in this energy range.

  19. Fragmentation of H2O by 1 -- 5 keV He^2+ ions: Experiment and Theory

    NASA Astrophysics Data System (ADS)

    Stolterfoht, N.; Hellhammer, R.; Sobocinski, P.; Cabrera-Trujillo, R.; Ohrn, Y.; Deumens, E.; Sabin, J.

    2006-05-01

    Fragmentation of H2O molecules induced by ^3He^2+ impact was investigated experimentally as a function of the energy in the range from 1-5 keV. Collisions at large impact parameters are found to produce fragment protons with energies centered around peaks at 6 eV and 15 eV. The H^+ fragments were detected in the angular range from 25 to 135 with respect to the incident beam direction. Absolute fragmentation cross sections dσ/dφ, differential in the emission angle are found to be anisotropic, with protons preferentially emitted at angles near 90 . In addition to the experiments, we performed quantum-mechanical calculations to understand the fragmentation mechanisms producing protons at preferred energies and angles. The theoretical results are obtained using the Electron-Nuclear Dynamics formalism (END), which solves the time-dependent Schr"odinger equation.

  20. Measurement of the 10 keV resonance in the B10(p,α0)Be7 reaction via the Trojan Horse method

    NASA Astrophysics Data System (ADS)

    Spitaleri, C.; Lamia, L.; Puglia, S. M. R.; Romano, S.; La Cognata, M.; Crucillà, V.; Pizzone, R. G.; Rapisarda, G. G.; Sergi, M. L.; Del Santo, M. Gimenez; Carlin, N.; Munhoz, M. G.; Souza, F. A.; Szanto de Toledo, A.; Tumino, A.; Irgaziev, B.; Mukhamedzhanov, A.; Tabacaru, G.; Burjan, V.; Kroha, V.; Hons, Z.; Mrazek, J.; Zhou, Shu-Hua; Li, Chengbo; Wen, Qungang; Wakabayashi, Y.; Yamaguchi, H.; Somorjai, E.

    2014-09-01

    The B10(p ,α0)Be7 bare nucleus astrophysical S (E) factor has been measured for the first time at energies from about 100 keV down to about 5 keV by means of the Trojan Horse method (THM). In this energy region, the S (E) factor is strongly dominated by the 8.699 MeV C11 level (Jπ=52+), producing an s-wave resonance centered at about 10 keV in the entrance channel. Up to now, only the high-energy tail of this resonance has been measured, while the low-energy trend is extrapolated from the available direct data. The THM has been applied to the quasifree H2(B10,α0 Be7)n reaction induced at a boron-beam energy of 24.5 MeV. An accurate analysis leads to the determination of the B10(p ,α0)Be7 S (E) factor and of the corresponding electron screening potential Ue, thus giving for the first time an independent evaluation of it.

  1. 48 CFR 970.1504-1-10 - Special considerations: Fee limitations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Special considerations: Fee limitations. 970.1504-1-10 Section 970.1504-1-10 Federal Acquisition Regulations System DEPARTMENT... Negotiation 970.1504-1-10 Special considerations: Fee limitations. In situations where the...

  2. 37 CFR 1.10 - Filing of correspondence by “Express Mail.”

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...Express Mail.â 1.10 Section 1.10 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND TRADEMARK... Information and Correspondence § 1.10 Filing of correspondence by “Express Mail.” (a)(1) Any correspondence received by the U.S. Patent and Trademark Office (USPTO) that was delivered by the “Express Mail...

  3. 30 CFR 57.22236 - Actions at 1.0 percent methane (VI mines).

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Actions at 1.0 percent methane (VI mines). 57... MINES Safety Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22236 Actions at 1.0 percent methane (VI mines). If methane reaches 1.0 percent in the mine atmosphere, all persons other...

  4. 30 CFR 57.22236 - Actions at 1.0 percent methane (VI mines).

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Actions at 1.0 percent methane (VI mines). 57... MINES Safety Standards for Methane in Metal and Nonmetal Mines Ventilation § 57.22236 Actions at 1.0 percent methane (VI mines). If methane reaches 1.0 percent in the mine atmosphere, all persons other...

  5. Measurements of proton induced γ-ray emission cross-sections on Mg from 1.0 to 3.0 MeV

    NASA Astrophysics Data System (ADS)

    Sharifzadeh, N.; Kakuee, O.; Mohammadi, S.

    2016-04-01

    Differential cross-section of proton induced γ-ray emission from the reactions 24Mg(p,p‧γ)24Mg (Eγ = 1369 keV), 25Mg(p,p‧γ)25Mg (Eγ = 390, 585, 975 keV) and 26Mg(p,γ)27Al (Eγ = 1014 keV) were measured for proton energies from 1 to 3 MeV using a 60 μg/cm2 Mg target evaporated on a 40 μg/cm2 Ag thin film. The γ-rays were collected by a 50% relative efficiency HPGe detector placed at an angle of 90° with respect to the beam direction, while the backscattered protons were collected by an ion implanted Si detector placed at a scattering angle of 165°. Simultaneous collection of γ-ray and RBS spectra is a great advantage of this approach which makes differential cross-section measurements independent on the collected beam charge. Measured cross-section values were compared with the previously reported data in the literature. Absolute γ-ray differential cross-sections were obtained with an overall systematic uncertainty of about ±6% and statistical uncertainty of less than ±5% for proton energies higher than 2.24 MeV.

  6. Understanding Bright 13 keV Kr K-shell X-ray Sources at the NIF

    NASA Astrophysics Data System (ADS)

    May, M. J.; Colvin, J. D.; Kemp, G. E.; Fournier, K. B.; Scott, H.; Patel, M.; Barrios, Widmann; Widmann, K.

    2015-11-01

    High x-ray conversion efficiency (CE) K-shell Kr sources are being investigated for High Energy Density experiments. These sources are 4.1 mm in diameter 4.4 mm tall hollow epoxy tubes having a 40 μm thick wall holding either 1.2 or 1.5 atm of Kr gas. The CE of K-shell Kr is dependent upon the peak electron temperature in the radiating plasma. In the NIF experiments, the available energy heats the source to Te = 6-7 keV, well below the temperature of Te ~25 keV needed to optimize the Kr CE. The CE is a steep function of the peak electron temperature. A spatially averaged electron temperature can be estimated from measured He(α) and Ly(α) line ratios. Some disagreement has been observed in the simulated and measured line ratios for some of these K-shell sources. Disagreements have been observed between the simulated and measured line ratios for some of these K-shell sources. To help understand this issue, Kr gas pipes have been shot with 3 ω light at ?750 kJ at ~210, ~140 TW and ~120 TW power levels with 3.7, 5.2 and 6.7 ns pulses, respectively. The power and pulse length scaling of the measured CE and K-shell line ratios and their comparison to simulations will be discussed. This work was performed under the auspic

  7. An Einstein survey of the 1 keV soft X-ray background in the Galactic plane

    NASA Technical Reports Server (NTRS)

    Stanford, John M.; Caillault, Jean-Pierre

    1994-01-01

    We have analyzed 56 Einstein Observatory Imaging Proportional Counter (IPC) observations within +/- 3 deg of the Galactic plane in order to determine the low-latitude soft X-ray background flux in the 0.56-1.73 keV band. Any detected X-ray point source which fell within our regions of study was removed from the image, enabling us to present maps of the background flux as a function of Galactic latitude along 18 meridians. These maps reveal considerable structure to the background in the Galactic plane on an angular scale of approximately 1 deg. Our results are compared with those of an earlier study of the 1 keV X-ray background along l = 25 deg by Kahn & Caillault. The double-peaked structure they found is not discernible in our results, possibly because of the presence of solar backscattered flux in their data. A model which takes into account contributions to the background by extragalactic and stellar sources, the distribution of both atomic and molecular absorbing material with the Galaxy, the energy dependence of the cross section for absorption of X-rays, and the energy dependence of the detector has been constructed and fitted to these new data to derive constraints on the scale height, temperature, and volume emissivity of the unaccounted-for X-ray-emitting material. The results of this model along l = 25 deg are roughly similar to those of the model of Kahn & Caillault along the same meridian.

  8. Effect of initial-state target polarization on the single ionization of helium by 1-keV electron impact

    NASA Astrophysics Data System (ADS)

    Sun, Shi-Yan; Ma, Xiao-Yan; Li, Xia; Miao, Xiang-Yang; Jia, Xiang-Fu

    2012-07-01

    We report new results of triple differential cross sections for the single ionization of helium by 1-KeV electron impact at the ejection energy of 10 eV. Investigations have been made for both the perpendicular plane and the plane perpendicular to the momentum transfer geometries. The present calculation is based on the three-Coulomb wave function. Here we have also incorporated the effect of target polarization in the initial state. A comparison is made between the present calculation with the results of other theoretical methods and a recent experiment [Dürr M, Dimopoulou C, Najjari B, Dorn A, Bartschat K, Bray I, Fursa D V, Chen Z, Madison D H and Ullrich J 2008 Phys. Rev. A 77 032717]. At an impact energy of 1 KeV, the target polarization is found to induce a substantial change of the cross section for the ionization process. We observe that the effect of target polarization plays a dominant role in deciding the shape of triple differential cross sections.

  9. Electron back-scattering coefficient below 5 keV: Analytical expressions and surface-barrier effects

    NASA Astrophysics Data System (ADS)

    Cazaux, J.

    2012-10-01

    Simple analytical expressions for the electron backscattering coefficient, η, are established from published data obtained in the ˜0.4-5 keV range for 21 elements ranging from Be to Au. They take into account the decline in η with a decrease in energy E° for high-Z elements and the reverse behavior for low-Z elements. The proposed expressions for η (E°) lead to crossing energies situated in the 0.4-1 keV range and they may be reasonably extended to any of the other elements—via an interpolation procedure—to metallic alloys and probably to compounds. The influence of the surface barrier on the escape probability of the back-scattered electrons is next evaluated. This evaluation provides a theoretical basis to explain the observed deviation between various published data as a consequence of surface contamination or oxidation. Various practical applications and strategies are deduced for the η-measurements in dedicated instruments as well for the image interpretation in low voltage scanning electron microscopy based on the backscattered electron detection. In this microscopy, the present investigation allows to generalize the scarce contrast changes and contrast reversals previously observed on multi elemental samples and it suggests the possibility of a new type of contrast: the work function contrast.

  10. High Resolution, 20-100 keV X-ray Backlighters for ICF and HEDS Experiments

    NASA Astrophysics Data System (ADS)

    Park, Hye-Sook; Koch, J. A.; Landen, O. L.; Phillips, T. W.; Schmid, G. J.

    2002-11-01

    We are studying the feasibility of high resolution radiography using short pulse high intensity lasers. Specifically we wish to better characterize and optimize the Kalpha X-ray production and brightness created by relativistic electron plasma interactions in the target material. We plan to utilize this Kalpha source as a backlighter to image various stages of implosions and planar driven high Z materials. Particularly interesting are the production of Kalpha's in the range 20 100 keV. In order to assess in detail the characteristics of such high energy X-ray backlighters, we are performing experiments using the 10 J, 100 fs JanUSP laser at LLNL. We will measure Kalpha source generation efficiency as function of laser beam parameters such as pulse duration, spot size and laser beam energy. We are also developing a high resolution hard X-ray imaging detector system. This paper will present initial results from the JanUSP experiments. Reference:D.K. Bradley, O.L. Landen, A.B. Bullock, S.G. Glendinning, and R.E. Turner, "Efficient, High Spatial-Temporal Resolution, 1-100 keV X-ray Radiography," Opt. Lett. 27(2002) 134.

  11. Energy.

    ERIC Educational Resources Information Center

    Online-Offline, 1998

    1998-01-01

    This issue focuses on the theme of "Energy," and describes several educational resources (Web sites, CD-ROMs and software, videos, books, activities, and other resources). Sidebars offer features on alternative energy, animal energy, internal combustion engines, and energy from food. Subthemes include harnessing energy, human energy, and…

  12. The Swift/Fermi GRB 080928 from 1 eV to 150 keV

    NASA Technical Reports Server (NTRS)

    Sonbas, Eda; Rossi, A.; Schulze, S.; Klose, S.; Kann, D. A.; Ferrero, P.; NicuesaGuelbenzu, A.; Rau, A.; Kruehler, T.; Greiner, J.; Schady, P.; Afonso, P. M. J.; Clemens, C.; Filgas, R.; KuepcuYoldas, A.; McBreen, S.; Olivares, F.; Szokoly, G.; Yoldas, A.; Krimm, H. A.; Johannesson, G.; Panaitescu, A.; Yuan, F.; Pandey, S. B.; Akerlof, C. W.

    2010-01-01

    We present the results of a comprehensive study of the Gamma-Ray Burst 080928 and of its afterglow. GRB 08092 was a long burst detected by Swift/BAT and Fermi/GBM, It is one of the exceptional cases where optical emission was already detected when the GRB itself was still radiating in the gamma-ray band. for nearly 100 seconds simultaneous optical X-ray and gamma-ray data provide a coverage of the spectral energy distribution of the transient source from about 1 eV to 150 keV. Here we analyze the prompt emission, constrain its spectral propertIes. and set lower limits on the initial Lorentz factor of the relativistic outflow, In particular. we show that the SED during the main prompt emission phase is in agreement with synchrotron radiation. We construct the optical/near-infrared light curve and the spectral energy distribution based on Swift/UVOT. ROTSE-Illa (Australia) and GROND (La Silla) data and compare it to the X-ray light curve retrieved from the Swift/XRT repository. We show that its bumpy shape can be modeled by multiple energy injections into the forward shock. Furthermore, we provide evidence that the temporal and spectral evolution of the first strong flare seen in the early X-ray light curve can be explained by large-angle emission. Finally, we report on the results of our search for the GRB host galaxy, for which only a deep upper limit can be provided.

  13. Development of heavy mineral and heavy element database of soil sediments in Japan using synchrotron radiation X-ray powder diffraction and high-energy (116 keV) X-ray fluorescence analysis: 1. Case study of Kofu and Chiba region.

    PubMed

    Bong, Willy Shun Kai; Nakai, Izumi; Furuya, Shunsuke; Suzuki, Hiroko; Abe, Yoshinari; Osaka, Keiichi; Matsumoto, Takuya; Itou, Masayoshi; Imai, Noboru; Ninomiya, Toshio

    2012-07-10

    We have started the construction of a nationwide forensic soil sediment database for Japan based on the heavy mineral and trace heavy element compositions of stream sediments collected at 3024 points all over Japan obtained by high-resolution synchrotron X-ray powder diffraction (SR-XRD) and high-energy synchrotron X-ray fluorescence analysis (HE-SR-XRF). In this study, the performance of both techniques was demonstrated by analyzing soil sediments from two different geological regions, the Kofu and Chiba regions in Kanto province, to construct database that can be applied in the future to provenance analysis of soil evidence from a crime scene. The sediments from the quaternary volcanic lithology of the Chiba region were found to be dominated by heavy minerals of volcanic origin - orthopyroxene, clinopyroxene, and amphibole, and the REEs (rare earth elements) within the region showed similar geochemical behavior. On the other hand, four distinct heavy mineral groups were identified in the sediments of the Kofu region, where there is a great variety of underlying bedrock, and the geochemical behavior of the REEs in the sediments also varied accordingly to their geological origins. As such, our study shows that high-resolution SR-XRD data can provide information on the spatial distribution patterns of heavy minerals in stream sediments, playing an important role in determining their likely geographical origin. Meanwhile, the highly sensitive HE-SR-XRF data allow us to study the geochemical behavior of trace heavy elements, especially the REEs in the sediments, providing additional support to further constrain the likely geographical origin of the sediments determined by heavy minerals.

  14. On the source of the 5-55 keV Heliosphere ENAs measured with Cassini/INCA

    NASA Astrophysics Data System (ADS)

    Dialynas, Konstantinos; Roelof, Edmond; Mitchell, Donald; Krimigis, Stamatios; Decker, Robert

    2016-07-01

    The Low Energy Charged Particle (LECP) in situ measurements from V1 and V2 have revealed a reservoir of ions and electrons that constitute the heliosheath (HS) after crossing the termination shock (TS) 35deg north and 32deg south of the ecliptic plane at 94 and 84 astronomical units (1 AU= 1.5 x10 ^{8} km), respectively. The outer Heliosphere boundary, the Heliopause (HP), has now been determined in the direction of V1 to be at ˜122 AU. The in situ measurements by each Voyager were placed in a global context by remote sensing images using ENA obtained with the Ion and Neutral Camera (INCA) onboard Cassini orbiting Saturn. The ENA images have revealed a 5.2-55 keV hydrogen (H) ENA region (Belt) that loops through the celestial sphere and contributes to balancing the pressure of the interstellar magnetic field (ISMF). Here we address one of the remaining and most important questions: Where do the 5-55 keV ENAs that INCA measures come from? We analyzed INCA all-sky maps from 2003 to 2015 and compare the solar cycle (SC) variation of the ENAs in both the nose (upstream) and anti-nose (downstream) directions with the intensities of > 30 keV ions (source of ENA through charge exchange-CE with H) measured in-situ by V1 and V2, in overlapping energy bands ˜30-55 keV. ENA intensities decrease during the declining phase of SC23 by ˜x3 from 2003 to 2011 but recover through 2014 (SC24); similarly, V1 and V2 ion intensities also decrease and then recover through 2014. The similarity of time profiles of remotely sensed ENA and locally measured ions are consistent with (a) ENA originating in the HS, and (b) the global HS responding promptly (within ˜1-1.5 years) to outward-propagating solar wind changes throughout the SC. Further, recovery of the Belt during SC24 precedes asymmetrically from south to north in the general direction of the nose. This may be related to the non-symmetric evolution of solar coronal holes during SC recovery.

  15. A DATABASE OF >20 keV ELECTRON GREEN'S FUNCTIONS OF INTERPLANETARY TRANSPORT AT 1 AU

    SciTech Connect

    Agueda, N.; Sanahuja, B.; Vainio, R.

    2012-10-15

    We use interplanetary transport simulations to compute a database of electron Green's functions, i.e., differential intensities resulting at the spacecraft position from an impulsive injection of energetic (>20 keV) electrons close to the Sun, for a large number of values of two standard interplanetary transport parameters: the scattering mean free path and the solar wind speed. The nominal energy channels of the ACE, STEREO, and Wind spacecraft have been used in the interplanetary transport simulations to conceive a unique tool for the study of near-relativistic electron events observed at 1 AU. In this paper, we quantify the characteristic times of the Green's functions (onset and peak time, rise and decay phase duration) as a function of the interplanetary transport conditions. We use the database to calculate the FWHM of the pitch-angle distributions at different times of the event and under different scattering conditions. This allows us to provide a first quantitative result that can be compared with observations, and to assess the validity of the frequently used term beam-like pitch-angle distribution.

  16. Origins of Anisotropic 40 300 keV Electron Events Observed at Low and High Latitudes

    NASA Astrophysics Data System (ADS)

    Hawkins, S. E., III; Gold, R. E.; Pick, M.; Maia, D.

    2001-05-01

    Using a survey of anisotropic electron events in the energy range of ˜40 300 keV observed by HI-SCALE on Ulysses, we have selected several time intervals during 1999 when Ulysses traveled from about 20° S at 5.2 AU (January 1999) to 42° S at 4.2 AU (January 2000). We compare these events with observations at ˜1 AU using the nearly identical instrument, EPAM on ACE. In order to study the solar origins of these electrons using the imaging Nançay Radioheliograph, we further restricted the list of events to those in which interplanetary magnetic field lines with origins on the visible solar disk, intersected Ulysses. We find that not all the anisotropic electron events are observed by both spacecraft and there exists a strong dependence on the spacecraft's magnetic connection back to the Sun. We have identified the solar origin for five electron events using radio observations, and correlate these with interplanetary type-III radio emissions using the WIND/WAVES experiment.

  17. The System of Nanosecond 280-KeV He+ Pulsed Beam

    SciTech Connect

    Junphong, P.; Ano, V.; Lekprasert, B.; Suwannakachorn, D.; Thongnopparat, N.; Vilaithong, T.; Wiedemann, H.; /SLAC /SLAC, SSRL

    2006-05-01

    At Fast Neutron Research Facility, the 150 kV-pulses neutron generator is being upgraded to a 280-kV-pulsed-He beam for time-of-flight Rutherford backscattering spectrometry. It involves replacing the existing beam line elements by a multicusp ion source, a 400-kV accelerating tube, 45{sup o}-double focusing dipole magnet and quadrupole lens. The multicusp ion source is a compact filament-driven of 2.6 cm in diameter and 8 cm in length. The current extracted is 20.4 {micro}A with 13 kV of extraction voltage and 8.8 kV of Einzel lens voltage. The beam emittance has found to vary between 6-12 mm mrad. The beam transport system has to be redesigned based on the new elements. The important part of a good pulsed beam depends on the pulsing system. The two main parts are the chopper and buncher. An optimized geometry for the 280 keV pulsed helium ion beam will be presented and discussed. The PARMELA code has been used to optimize the space charge effect, resulting in pulse width of less than 2 ns at a target. The calculated distance from a buncher to the target is 4.6 m. Effects of energy spread and phase angle between chopper and buncher have been included in the optimization of the bunch length.

  18. Effects of combined irradiation of 500 keV protons and atomic oxygen on polyimide films

    NASA Astrophysics Data System (ADS)

    Novikov, Lev; Chernik, Vladimir; Zhilyakov, Lev; Voronina, Ekaterina; Chirskaia, Natalia

    2016-07-01

    Polyimide films are widely used on the spacecraft surface as thermal control coating, films in different constuctions, etc. However, the space ionizing radiation of different types can alter the mechanical, optical and electrical properties of polyimide films. For example, it is well known that 20-100 keV proton irradiation causes breaking of chemical bonds and destruction of the surface layer in polyimide, deterioration of its optical properties, etc. In low-Earth orbits serious danger for polymeric materials is atomic oxygen of the upper atmosphere of the Earth, which is the main component in the range of heights of 200-800 km. Due to the orbital spacecraft velocity, the collision energy of oxygen atoms with the surface ( 5 eV) enhances their reactivity and opens additional pathways of their reaction with near-surface layers of materials. Hyperthermal oxygen atom flow causes erosion of the polyimide surface by breaking chemical bonds and forming of volatiles products (primarily, CO and CO _{2}), which leads to mass losses and degradation of material properties. Combined effect of protons and oxygen plasma is expected to give rise to synergistic effects enhancing the destruction of polyimide surface layers. This paper describes experimental investigation of polyimide films sequential irradiation with protons and oxygen plasma. The samples were irradiated by 500 keV protons at fluences of 10 ^{14}-10 ^{16} cm ^{-2} produced with SINP cascade generator KG-500 and 5-20 eV neutral oxygen atoms at fluence of 10 ^{20} cm ^{-2} generated by SINP magnetoplasmodynamics accelerator. The proton bombardment causes the decrease in optical transmission coefficient of samples, but their transmittance recovers partially after the exposure to oxygen plasma. The results of the comparative analysis of polyimide optical transmission spectra, Raman and XPS spectra obtained at different stages of the irradiation of samples, data on mass loss of samples due to erosion of the surface are

  19. An X-ray Raman spectrometer for EXAFS studies on minerals: bent Laue spectrometer with 20 keV X-rays.

    PubMed

    Hiraoka, N; Fukui, H; Tanida, H; Toyokawa, H; Cai, Y Q; Tsuei, K D

    2013-03-01

    An X-ray Raman spectrometer for studies of local structures in minerals is discussed. Contrary to widely adopted back-scattering spectrometers using ≤10 keV X-rays, a spectrometer utilizing ~20 keV X-rays and a bent Laue analyzer is proposed. The 20 keV photons penetrate mineral samples much more deeply than 10 keV photons, so that high intensity is obtained owing to an enhancement of the scattering volume. Furthermore, a bent Laue analyzer provides a wide band-pass and a high reflectivity, leading to a much enhanced integrated intensity. A prototype spectrometer has been constructed and performance tests carried out. The oxygen K-edge in SiO(2) glass and crystal (α-quartz) has been measured with energy resolutions of 4 eV (EXAFS mode) and 1.3 eV (XANES mode). Unlike methods previously adopted, it is proposed to determine the pre-edge curve based on a theoretical Compton profile and a Monte Carlo multiple-scattering simulation before extracting EXAFS features. It is shown that the obtained EXAFS features are reproduced fairly well by a cluster model with a minimal set of fitting parameters. The spectrometer and the data processing proposed here are readily applicable to high-pressure studies.

  20. Obtaining 1-10 nm optimal beam spot size in the magnetic quadrupole nanoprobe

    NASA Astrophysics Data System (ADS)

    Dymnikov, A.; Glass, G.

    2012-02-01

    Focusing of high energy charged particles in an octuplet lens system comprised of two Russian quadruplets, defined as the Lafayette Octuplet, is investigated. This octuplet is a zoom system having the same demagnifications, the same focal lengths, and the same positions of the focal points in xz and yz planes as the Russian quadruplet. In this study the matrix method of embedding in the space of the phase moments is used to solve the non-linear equations of motion. With this method all the advantages of the linear differential equations are used, including the independence of the matrizant of the non-linear motion on the choice of the initial point of the phase space. For the same phase volume (or beam current) the spot size is minimized (optimized) by a set of two optimal matching slits: objective and divergence slits. This optimal spot size is a function of the four-dimensional emittance and both geometric and optical parameters of the system. Geometric parameters include total system length, lens lengths, drift spaces, object and working distances, minimum attainable slit openings while optical parameters include demagnifications, spherical and chromatic aberrations. The optimal beam spot size and appropriate optimal slits have been found as functions of the emittance of the system for different geometries. It is shown that the octuplets investigated here allow the possibility to obtain 1-10 nm optimal beam spot sizes. The influence of the beam energy spread on the optimal beam spot size is studied.

  1. Synthetic multilayer x-ray dispersion elements for 200 A (62 eV) to 0. 62 A (20 keV) radiation. Final report

    SciTech Connect

    Barbee, T.W. Jr.

    1983-11-01

    This final report concerns research performed at Stanford University on a program sponsored by the Department of Energy through Lawrence Livermore National Laboratory and the Regents of the University of California (Subcontract No. 2695501) entitled Synthetic Multilayer X-ray Dispersion Elements for 200 A (62 eV) to 0.62 A (20 keV) Radiation. The thrust of the research was to investigate the synthesis process parameter dependence of the nature of the interfaces between constituent adjacent layers, the uniformity of layers, and the reflectivity for light of wavelengths 0.62 A to 200 A of synthetic multilayer crystals. Additionally, device development was to be undertaken with emphasis on spectrum analyzing dispersion elements, high energy Kirkpatrick-Baez X-ray microscope mirrors, multi-keV (1 to 5 keV) X-ray applications, X-ray beam splitters and synthetic multilayers fabricated from adjoining elements in the periodic table.

  2. A laboratory 8 keV transmission full-field x-ray microscope with a polycapillary as condenser for bright and dark field imaging

    SciTech Connect

    Baumbach, S. Wilhein, T.; Kanngießer, B.; Malzer, W.; Stiel, H.

    2015-08-15

    This article introduces a laboratory setup of a transmission full-field x-ray microscope at 8 keV photon energy. The microscope operates in bright and dark field imaging mode with a maximum field of view of 50 μm. Since the illumination geometry determines whether the sample is illuminated homogeneously and moreover, if different imaging methods can be applied, the condenser optic is one of the most significant parts. With a new type of x-ray condenser, a polycapillary optic, we realized bright field imaging and for the first time dark field imaging at 8 keV photon energy in a laboratory setup. A detector limited spatial resolution of 210 nm is measured on x-ray images of Siemens star test patterns.

  3. A laboratory 8 keV transmission full-field x-ray microscope with a polycapillary as condenser for bright and dark field imaging

    NASA Astrophysics Data System (ADS)

    Baumbach, S.; Kanngießer, B.; Malzer, W.; Stiel, H.; Wilhein, T.

    2015-08-01

    This article introduces a laboratory setup of a transmission full-field x-ray microscope at 8 keV photon energy. The microscope operates in bright and dark field imaging mode with a maximum field of view of 50 μm. Since the illumination geometry determines whether the sample is illuminated homogeneously and moreover, if different imaging methods can be applied, the condenser optic is one of the most significant parts. With a new type of x-ray condenser, a polycapillary optic, we realized bright field imaging and for the first time dark field imaging at 8 keV photon energy in a laboratory setup. A detector limited spatial resolution of 210 nm is measured on x-ray images of Siemens star test patterns.

  4. Cross-section measurement of the /sup 3/He(n,. gamma. ) reaction at E/sub n/ = 24. 5 keV

    SciTech Connect

    Wervelman, R.; Abrahams, K.; Stecher-Rasmussen, F. ); Postma, H.; Davids, G.J.; Bots, G.J.C. )

    1989-08-01

    At 24.5-keV neutron energy, the radiative capture of neutrons proceeds with only a few parts per million compared to to the scattering and (n,p) reactions. Nevertheless, the radiative capture is of interest in the study of fusion reactions, which occur in the sun or in fusion reactors. This reaction yields very high energy (20.6-MeV) gamma rays which are outstanding above any background and therefore may be of diagnostic value in fusion reactor research. A cross-section value {sigma}/sub n{gamma}/ (24.5 keV) = 9.2 +- 2.0 {mu}b is obtained, which is in good agreement with the value 12 +- 6 {mu}b from earlier literature.

  5. Topography evolution of 500 keV Ar(4+) ion beam irradiated InP(100) surfaces - formation of self-organized In-rich nano-dots and scaling laws.

    PubMed

    Sulania, Indra; Agarwal, Dinesh C; Kumar, Manish; Kumar, Sunil; Kumar, Pravin

    2016-07-27

    We report the formation of self-organized nano-dots on the surface of InP(100) upon irradiating it with a 500 keV Ar(4+) ion beam. The irradiation was carried out at an angle of 25° with respect to the normal at the surface with 5 different fluences ranging from 1.0 × 10(15) to 1.0 × 10(17) ions per cm(2). The morphology of the ion-irradiated surfaces was examined by atomic force microscopy (AFM) and the formation of the nano-dots on the irradiated surfaces was confirmed. The average size of the nano-dots varied from 44 ± 14 nm to 94 ± 26 nm with increasing ion fluence. As a function of the ion fluence, the variation in the average size of the nano-dots has a great correlation with the surface roughness, which changes drastically up to the ion fluence of 1.0 × 10(16) ions per cm(2) and attains almost a saturation level for further irradiation. The roughness and the growth exponent values deduced from the scaling laws suggest that the kinetic sputtering and the large surface diffusion steps of the atoms are the primary reasons for the formation of the self-organized nanodots on the surface. X-ray photo-electron spectroscopy (XPS) studies show that the surface stoichiometry changes with the ion fluence. With irradiation, the surface becomes more indium (In)-rich owing to the preferential sputtering of the phosphorus atoms (P) and the pure metallic In nano-dots evolve at the highest ion fluence. The cross-sectional scanning electron microscopy (SEM) analysis of the sample irradiated with the highest fluence showed the absence of the nanostructuring beneath the surface. The surface morphological changes at this medium energy ion irradiation are discussed in correlation with the low and high energy experiments to shed more light on the mechanism of the well separated nano-dot formation.

  6. Nuclear resonant forward scattering of synchrotron radiation from 121 Sb at 37.13 keV.

    SciTech Connect

    Wille, H. C.; Shvydko, Y. V.; Alp, E. E.; Ruter, H. D.; Leupold, O.; Sergueev, I.; Ruffer, R.; Barla, A.; Sanchez, J. P.; X-Ray Science Division; European Synchrotron Radiation Facility; Univ. of Hamburg; Hamburder Synchrotronstrahlungslabor

    2006-02-22

    We report on the observation of nuclear resonant forward scattering of synchrotron radiation from {sup 121}Sb nuclei. A temperature stabilized {alpha}Al{sub 2}O{sub 3} crystal Bragg backscattering high-resolution monochromator with a relative energy resolution of 2 x 10{sup -7} was introduced. As first spectroscopic applications the hyperfine parameters in Sb{sub 2}O{sub 3}, USb and DySb were determined. The energy of the nuclear transition in {sup 121}Sb was measured to be 37.1298(2)keV, 40 times more precisely than reported before. The results open the field of nuclear resonance spectroscopy on antimony compounds taking advantage of the outstanding features of 3rd-generation synchrotron sources. Nuclear resonance scattering on Sb compounds at these sources allows element-specific dynamical studies on thermoelectric materials as well as studies on magnetism in micro- and nanometer dimensional systems like spintronic devices.

  7. Injection and diffusive transport of suprathermal through energetic solar flare protons (35 keV to 20 MeV)

    NASA Technical Reports Server (NTRS)

    Beeck, J.; Mason, G. M.; Hamilton, D. C.; Marsden, R. G.; Sanderson, T. R.

    1990-01-01

    Consideration is given to the injection and interplanetary propagation of low-energy protons caused by the solar particle event of July 20, 1981, in which flare protons in the range from 35 keV to 20 MeV were observed by instruments on ISEE 3. The observed time-intensity and time-anisotropy profiles were fitted over the entire energy range using a model based on the spherically symmetric Fokker-Plank equation, including convection, diffusion, and adiabatic deceleration. The results are used to discuss the behavior of the radial interplanetary diffusion coefficient and the scattering mean free path for protons. Also, evidence is found for diffusive coronal shock acceleration of protons during the event.

  8. AMANDE: a new facility for monoenergetic neutron fields production between 2 keV and 20 MeV.

    PubMed

    Gressier, V; Guerre-Chaley, J F; Lacoste, V; Lebreton, L; Pelcot, G; Pochat, J L; Bolognese-Milstajn, T; Champion, D

    2004-01-01

    The variation of the response of the instruments with the neutron energy has to be determined in well-characterized monoenergetic neutron fields. The AMANDE facility will deliver such neutron fields between 2 keV and 20 MeV in an experimental hall designed with metallic walls for neutron scattering minimisation. The neutrons will be produced by nuclear interaction of accelerated protons or deuterons on thin targets of selected materials. The measuring devices to be characterised will be accurately placed with a fully automated detector transport system. The energy of the neutron field will be validated by time-of-flight experiments and a large set of standard detectors and fluence monitors will be used to determine the neutron fluence references. The scattered neutron fluence and dose equivalent were calculated by the MCNP Monte Carlo code at several measuring points in order to determine their contribution to the neutron field.

  9. INTEGRAL Observations of the Galactic 511 keV Emission and MeV Gamma-ray Astrophysics

    NASA Technical Reports Server (NTRS)

    Watanabe, Ken

    2005-01-01

    Although there are a number of interesting phenomena, such as Nucleosynthesis in stars, in the MeV energy region, the observations have been difficult due to a small signal to noise (background) ratio (less than 1%). While NASA's Compton Gamma-ray Observatory (CGRO) enabled us to explore the Gamma-ray universe, ESA's INTEGRAL mission, launched in 2002, is providing us more detailed information with its superior energy and angular resolution. We will briefly discuss some of the current issues in MeV Gamma-ray Astrophysics. Then, we will focus on the Galactic 511 keV emission with the latest INTEGRAL observations, and talk about challenges we currently have.

  10. Observation of the emission of positive and negative ions in triple and quadruple collisions in a solid under bombardment with keV argon ions

    NASA Astrophysics Data System (ADS)

    Babenko, P. Yu.; Shergin, A. P.

    2006-12-01

    Particles that leave a solid as a result of several consecutive binary collisions are detected in the energy spectra of positive and negative ions emitted upon the irradiation of C, Si, Ge, and In targets with 2-to 5-keV Ar+ ions. The appearance of a spectral structure due to the sequence of three and four collisions in the solid can be attributed to the selective role of the surface, which is similar to the channeling effect in crystals.

  11. Electron collisional detachment processes for a 250 keV D/sup -/ ion beam in a partially ionized hydrogen target

    SciTech Connect

    Savas, S.E.

    1980-09-01

    Neutral atom beams with energies above 200 keV may be required for various purposes in magnetic fusion devices following TFTR, JET and MFTF-B. These beams can be produced much more efficiently by electron detachment from negative ion beams than by electron capture by positive ions. We have investigated the efficiency with which such neutral atoms can be produced by electron detachment in partially ionized hydrogen plasma neutralizers.

  12. 1-40-keV fixed-exit monochromator for a wafer mapping TXRF facility

    NASA Astrophysics Data System (ADS)

    Comin, Fabio; Apostolo, G.; Freund, Andreas K.; Mangiagalli, P.; Navizet, M.; Troxel, C. L.

    1998-12-01

    An industrial facility for the mapping of trace impurities on the surface of 300 mm Silicon wafers will be commissioned at the end of 1998. The elements to be detected range from Na to Hg with a target routine detection limit of 108 atoms/cm2. The monochromator of the facility plays a central role and fulfills the following requirements: ease of operations and fast tuning (one single motor); extended energy range (1 - 40 KeV covered by a fixed exit Si(111) channel cut and multilayer pair); smooth and reliable running (water cooling even in the powerful ESRF undulator beams at high energies). The mechanical structure of the monochromator is based on well-established concepts: an external goniometer transfers the main rotation to the in-vacuum plateau via a hollow differentially pumped feed-through. The optical arrangement shows some novelties: the plateau can be cooled either by water or liquid nitrogen and it holds the convex- concave machined Si(111) channel-cut for fixed exit performances. The shape of the machined surfaces of the crystal helps also on to spread the power density of the beam on the silicon surface. A set of two identical multilayers are also mounted on the plateau and the transition from the Si(111) crystal to the multilayer operation is performed by rotating the wafer main axis by about 180 degrees. The whole facility is centered around the three main components: the monochromator, the wafer handling robots and the two linear arrays of solid state fluorescence detectors.

  13. BADGER v1.0: A Fortran equation of state library

    NASA Astrophysics Data System (ADS)

    Heltemes, T. A.; Moses, G. A.

    2012-12-01

    The BADGER equation of state library was developed to enable inertial confinement fusion plasma codes to more accurately model plasmas in the high-density, low-temperature regime. The code had the capability to calculate 1- and 2-T plasmas using the Thomas-Fermi model and an individual electron accounting model. Ion equation of state data can be calculated using an ideal gas model or via a quotidian equation of state with scaled binding energies. Electron equation of state data can be calculated via the ideal gas model or with an adaptation of the screened hydrogenic model with ℓ-splitting. The ionization and equation of state calculations can be done in local thermodynamic equilibrium or in a non-LTE mode using a variant of the Busquet equivalent temperature method. The code was written as a stand-alone Fortran library for ease of implementation by external codes. EOS results for aluminum are presented that show good agreement with the SESAME library and ionization calculations show good agreement with the FLYCHK code. Program summaryProgram title: BADGERLIB v1.0 Catalogue identifier: AEND_v1_0 Program summary URL:http://cpc.cs.qub.ac.uk/summaries/AEND_v1_0.html Program obtainable from: CPC Program Library, Queen's University, Belfast, N. Ireland Licensing provisions: Standard CPC licence, http://cpc.cs.qub.ac.uk/licence/licence.html No. of lines in distributed program, including test data, etc.: 41 480 No. of bytes in distributed program, including test data, etc.: 2 904 451 Distribution format: tar.gz Programming language: Fortran 90. Computer: 32- or 64-bit PC, or Mac. Operating system: Windows, Linux, MacOS X. RAM: 249.496 kB plus 195.630 kB per isotope record in memory Classification: 19.1, 19.7. Nature of problem: Equation of State (EOS) calculations are necessary for the accurate simulation of high energy density plasmas. Historically, most EOS codes used in these simulations have relied on an ideal gas model. This model is inadequate for low

  14. Angular scattering of 1-50 keV ions through graphene and thin carbon foils: potential applications for space plasma instrumentation.

    PubMed

    Ebert, Robert W; Allegrini, Frédéric; Fuselier, Stephen A; Nicolaou, Georgios; Bedworth, Peter; Sinton, Steve; Trattner, Karlheinz J

    2014-03-01

    We present experimental results for the angular scattering of ~1-50 keV H, He, C, O, N, Ne, and Ar ions transiting through graphene foils and compare them with scattering through nominal ~0.5 μg cm(-2) carbon foils. Thin carbon foils play a critical role in time-of-flight ion mass spectrometers and energetic neutral atom sensors in space. These instruments take advantage of the charge exchange and secondary electron emission produced as ions or neutral atoms transit these foils. This interaction also produces angular scattering and energy straggling for the incident ion or neutral atom that acts to decrease the performance of a given instrument. Our results show that the angular scattering of ions through graphene is less pronounced than through the state-of-the-art 0.5 μg cm(-2) carbon foils used in space-based particle detectors. At energies less than 50 keV, the scattering angle half width at half maximum, ψ(1/2), for ~3-5 atoms thick graphene is up to a factor of 3.5 smaller than for 0.5 μg cm(-2) (~20 atoms thick) carbon foils. Thus, graphene foils have the potential to improve the performance of space-based plasma instruments for energies below ~50 keV.

  15. Angular scattering of 1–50 keV ions through graphene and thin carbon foils: Potential applications for space plasma instrumentation

    SciTech Connect

    Ebert, Robert W.; Allegrini, Frédéric; Fuselier, Stephen A.; Nicolaou, Georgios; Bedworth, Peter; Sinton, Steve; Trattner, Karlheinz J.

    2014-03-15

    We present experimental results for the angular scattering of ∼1–50 keV H, He, C, O, N, Ne, and Ar ions transiting through graphene foils and compare them with scattering through nominal ∼0.5 μg cm{sup −2} carbon foils. Thin carbon foils play a critical role in time-of-flight ion mass spectrometers and energetic neutral atom sensors in space. These instruments take advantage of the charge exchange and secondary electron emission produced as ions or neutral atoms transit these foils. This interaction also produces angular scattering and energy straggling for the incident ion or neutral atom that acts to decrease the performance of a given instrument. Our results show that the angular scattering of ions through graphene is less pronounced than through the state-of-the-art 0.5 μg cm{sup −2} carbon foils used in space-based particle detectors. At energies less than 50 keV, the scattering angle half width at half maximum, ψ{sub 1/2}, for ∼3–5 atoms thick graphene is up to a factor of 3.5 smaller than for 0.5 μg cm{sup −2} (∼20 atoms thick) carbon foils. Thus, graphene foils have the potential to improve the performance of space-based plasma instruments for energies below ∼50 keV.

  16. Strength of the Ec.m.=1113 keV resonance in 20Ne(p,γ)21Na

    NASA Astrophysics Data System (ADS)

    Christian, G.; Hutcheon, D.; Akers, C.; Connolly, D.; Fallis, J.; Ruiz, C.

    2013-09-01

    The 20Ne(p,γ)21Na reaction is the starting point of the NeNa cycle, which is an important process for the production of intermediate mass elements. The Ec.m.=1113 keV resonance plays an important role in the determination of stellar rates for this reaction since it is used to normalize experimental direct capture yields at lower energies. The commonly accepted strength of this resonance, ωγ=1.13±0.07 eV, has been misinterpreted as the strength in the center-of-mass frame when it is actually the strength in the laboratory frame. This has motivated a new measurement of the Ec.m.=1113 keV resonance strength in 20Ne(p,γ)21Na using the DRAGON recoil mass spectrometer. The DRAGON result, 0.972±0.11 eV, is in good agreement with the accepted value when both are calculated in the same frame of reference.

  17. Interaction of 18-keV O{sup -} ions with Al{sub 2}O{sub 3} nanocapillaries

    SciTech Connect

    Sun Guangzhi; Chen Ximeng; Wang Jun; Chen Yifeng; Xu Junkui; Zhou Chunlin; Shao Jianxiong; Cui Ying; Ding Baowei; Yin Yongzhi; Wang Xinan; Lou Fengjun; Lv Xueyang; Qiu Xiyu; Jia Juanjuan; Chen Lin; Xi Fayuan; Chen Zichun; Li Lanting; Liu Zhaoyuan

    2009-05-15

    The transmission of 18-keV O{sup -} ions through Al{sub 2}O{sub 3} nanocapillaries with 50 nm in diameter and 12 {mu}m in length is studied in this work. By measuring angular distribution of transmitted particles when capillaries were tilted with respect to incident ion beam, two peaks were observed. It is distinguished that one of them is composed by direct transmitted ions and another one is composed by scattered ions. A phenomenon referred to as guiding effect, as found for highly charged ions and low-energy electrons, was observed. When negative ions (18-keV O{sup -}) are transmitted through nanocapillaries, most of them were ionized to neutral atoms and even positive ions. The intensity of transmitted particles (O{sup -}, O{sup 0}, and O{sup +}) decreased when the tilt angle increased. In transmitted particles, the fraction of O{sup -} declined but that of O{sup 0} and O{sup +} ions grew when the tilt angle grew. Both elastic collision and electrostatic scattering were found in scattered ions.

  18. Electric Fields Associated with Deep Injections of 10s to 100s keV Electrons in the Inner Magnetosphere

    NASA Astrophysics Data System (ADS)

    Califf, S.; Li, X.; Jaynes, A. N.; Zhao, H.; Malaspina, D.

    2015-12-01

    Recent observations by HOPE and MagEIS onboard the Van Allen Probes show frequent penetration of 10s to 100s keV electrons through the slot region and into the inner belt, resulting in an abundant electron population below L=3. The conventional picture is that the source populations of these 10s to 100s keV electrons originate in the plasma sheet and are injected (along with plasma sheet ions) into the inner magnetosphere either through enhancements in the large-scale convection electric field and/or through earthward propagating dipolarization fronts associated with substorms. In such cases the inward radial limit of the injections should coincide with the plasmapause. However, these electron injections often extend inside the plasmasphere, are observed far earthward of the typically accepted "flow-braking" region for dipolarization fronts, and occur at much lower L shells than injections of ions with similar energies. We investigate the electric fields associated with these deep electron injections using data from the Van Allen Probes and THEMIS in order to shed light on the underlying mechanisms that allow them to penetrate so far into the inner magnetosphere.

  19. Generalized spectra model for 1-100 keV X-ray emission from Cygnus X-3 based on EXOSAT data

    NASA Astrophysics Data System (ADS)

    Rajeev, M. R.; Chitnis, V. R.; Rao, A. R.; Singh, K. P.

    1994-03-01

    The X-ray spectrum of the highly variable X-ray source, Cyg X-3, has so far defied a consistent explanation based on simple emission models. We have extracted two of the best data sets from the EXOSAT archives and performed a detailed spectral analysis for its 'high' and 'low' states. The analysis of the less frequently occurring 'low' state is presented for the first time for the EXOSAT data. Combining data from the medium-energy argon and xenon detectors and the gas scintillation proportional counter, with a better energy resolution, and carrying out a simultaneous fit, we find that the X-ray continuum in both the 'high' and 'low' state can be explained as a sum of a blackbody emission and emission from a Comptonized plasma cloud with a common absorption. The Comptonization model is sufficient as well as preferable to many other models, in explaining the observed X-ray emission up to 100 keV. In addition, we find an emission-line feature due to ionized iron (Fe XX-Fe XXVI) and absorption features due to cold iron (Fe I) as well as highly ionized iron (Fe XXV-Fe XXXVI). The presence of absorption due to Fe I has been shown for the first time here. This is the simplest and the most generalized spectral model for the 1-100 keV X-ray emission from Cyg X-3, to date. We find that the blackbody temperature derived in the 'high ' state (1.47 keV) is much lower than that derived for the 'low' state (2.40 keV) and is associated with an increase in the blackbodly radius in the 'high' state. The ratio of blackbody flux to the total flux is approximately 0.61 in the 'high' state and approximately 0.44 in the 'low' state. The Fe line energy is significantly higher in the 'high' state (approximately 6.95 keV) compared to the 'low' state (approximately 6.56 keV). The Comptonization parameter changes from 2 to approximately 15 in going from the 'high' to the 'low' state implying a highly saturated Comptonization in the 'low' state. The Comptonized region has high electron

  20. The origin of perpendicular magneto-crystalline anisotropy in L1(0)-FeNi under tetragonal distortion.

    PubMed

    Miura, Yoshio; Ozaki, Sho; Kuwahara, Yasushi; Tsujikawa, Masahito; Abe, Kazutaka; Shirai, Masafumi

    2013-03-13

    We investigated the origin of perpendicular magneto-crystalline anisotropy (MCA) in L1(0)-ordered FeNi alloy using first-principles density-functional calculations. We found that the perpendicular MCA of L1(0)-FeNi arises predominantly from the constituent Fe atoms, which is consistent with recent measurements of the anisotropy of the Fe orbital magnetic moment of L1(0)-FeNi by means of x-ray magnetic circular dichroism. Analysis of the second-order perturbation of the spin-orbit interaction indicates that spin-flip excitations between the occupied majority-spin and unoccupied minority-spin bands make a considerable contribution to the perpendicular MCA, as does the spin-conservation term for the minority-spin bands. Furthermore, the MCA energy increases as the in-plane lattice parameter decreases (increasing the axial ratio c/a). The increase in the MCA energy can be attributed to further enhancement of the spin-flip term due to modulation of the Fe d(xy) and d(x(2) - y(2)) orbital components around the Fermi level under compressive in-plane distortion.

  1. WE-E-BRE-08: Impact of IUdR in Rat 9L Glioma Cell Survival for 25–35 KeV Photo-Activated Auger Electron Therapy

    SciTech Connect

    Alvarez, D; Hogstrom, K; Brown, T; Dugas, J; Varnes, M; Matthews, K

    2014-06-15

    Purpose: To determine the biological effect from Auger electrons with 9% and 18% iododeoxyuridine (IUdR) incorporated into the DNA of rat 9L glioma cells at photon energies above and below the K-edge of iodine (33.2 keV). Methods: Rat 9L glioma cell survival versus dose curves with 0%, 9%, and 18% thymidine replacement with IUdR were measured using four irradiation energies (4 MV x-rays; monochromatic 35, 30, and 25 keV synchrotron photons). For each of 11 conditions (Energy, %IUdR) survival curves were fit to the data (826 cell cultures) using the linear-quadratic model. The ratio of doses resulting in 10% survival gave sensitization enhancement ratios (SER10) from which contributions due to linear-energy transfer (LET), radiosensitization (RS), and Auger effect (AE) were extracted. Results: At 35, 30, and 25 keV, SER10,LET values were 1.08±0.03, 1.22±0.02, and 1.37±0.02, respectively. At 4 MV SER10,RS values for 9% and 18% IUdR were 1.28±0.02 and 1.40±0.02, respectively. Assuming LET effects are independent of %IUdR and radiosensitization effects are independent of energy, SER10,AE values for 18% IUdR at 35, 30, and 25 keV were 1.35±0.05, 1.06±0.03, and 0.98±0.03, respectively; values for 9% IUdR at 35 and 25 keV were 1.01±0.04 and 0.82±0.02, respectively. Conclusion: For 18% IUdR the radiosensitization effect of 1.40 and the Auger effect of 1.35 at 35 keV are equally important to the combined effect of 1.90. No measureable Auger effect was observed for energies below the K-edge at 20 and 25 keV, as expected. The insignificant Auger effect at 9% IUdR was not expected. Additional data (40–70 keV) and radiobiological modeling are being acquired to better understand the energy dependence of Auger electron therapy with IUdR. Funding support in part by the National Science Foundation Graduate Research Fellowship Program and in part by Contract No. W81XWH-10-1-0005 awarded by the U.S. Army Research Acquisition Activity. This paper does not necessarily

  2. Solar Cycle dependence of 5-55 keV Cassini/INCA energetic neutral atom (ENA) images of the Heliosheath and in situ Voyager/LECP ion measurements

    NASA Astrophysics Data System (ADS)

    Krimigis, S. M.; Dialynas, K.; Mitchell, D. G.; Decker, R. B.; Roelof, E. C.

    2015-12-01

    The heliosheath has been identified as the most probable source of ENAs that INCA detects but its variability due to solar activity throughout the solar cycle (SC) has not been resolved to date. We show all-sky, 5-55 keV ENA H maps from the year 2003 to 2014 and compare the solar cycle variation of the ENAs in both the heliospheric nose (upstream) and anti-nose (downstream) directions with the > 30 keV ions measured within the heliosheath by the Low Energy Charged Particle (LECP) detector on Voyagers 1, 2 (V1, V2) where we measure protons in overlapping energy bands ~30-55 keV. We find that a) Toward the anti-nose direction the ENA-H intensities decline during SC23, i.e. after 2003 ENA intensities decreased by ~ x2 at all energies by the end of year 2011, ~1 year after the observed minimum in solar activity; b) This ENA decrease (5.2-55 keV) during 2009-2011 is consistent with the concurrent intensity decrease of the > 30 keV ions (by a factor of 2-3) observed in situ by V1 and V2 in the heliosheath; c) Toward the nose direction, minimum intensities in both INCA ENAs and the V2 ions at E > 28 keV occur during the year 2013, with a subsequent recovery from 2014 to date (by a factor of ~2 in the > 35 keV ENA data). These quantitative correlations between the decreases of INCA ENAs (in both the heliospheric nose and anti-nose directions) and the in situ V1 and V2 ion measurements (separated by > 130 AU) during the declining phase of SC23, along with their concurrent jointly shared recoveries at the onset of SC24, imply that: 1) the 5-55 keV ENAs are produced in the heliosheath (because their transit times over 100 AU are less than a few months at energies > 40 keV), thus proving that our ENA observations can provide the ground truth for constructing comprehensive global heliosphere models; 2) the global heliosheath responds promptly (within ~1-1.5 yrs) to outward-propagating solar wind changes throughout the solar cycle.

  3. Fatigue failure stages of VT1-0 titanium in different structural states. Study by acoustic emission method

    NASA Astrophysics Data System (ADS)

    Bashkov, O. V.; Sharkeev, Yu. P.; Panin, S. V.; Kim, V. A.; Bashkova, T. I.; Popkova, A. A.; Eroshenko, A. Yu.; Tolmachev, A. I.

    2016-11-01

    The paper studies the kinetics of fatigue damage accumulation in VT1-0 titanium by the acoustic emission (AE) method. Technical grade titanium VT1-0 in various structural states was tested under cyclic bending. Submicrocrystalline Ti-specimens (SMC, with subgrain size of 200-300 nm) were fabricated by equal channel angular pressing (ECAP) from polycrystalline titanium. Ingots with ultrafine grain structure (UFG, with structure element size of 1-2 µm) and coarse grain structure (CG, with structure element size of 20-30 µm) were prepared by annealing at different temperatures. Fatigue stages were identified by analyzing the AE signal parameters with their classification by the source type (dislocations, micro-and macrocracks). It was revealed that the specimens with a smaller grain size are of higher fatigue durability, while AE signals at the stages of yielding and microcracking are detected later because of their low energy.

  4. CaveMan Enterprise version 1.0 Software Validation and Verification.

    SciTech Connect

    Hart, David

    2014-10-01

    The U.S. Department of Energy Strategic Petroleum Reserve stores crude oil in caverns solution-mined in salt domes along the Gulf Coast of Louisiana and Texas. The CaveMan software program has been used since the late 1990s as one tool to analyze pressure mea- surements monitored at each cavern. The purpose of this monitoring is to catch potential cavern integrity issues as soon as possible. The CaveMan software was written in Microsoft Visual Basic, and embedded in a Microsoft Excel workbook; this method of running the CaveMan software is no longer sustainable. As such, a new version called CaveMan Enter- prise has been developed. CaveMan Enterprise version 1.0 does not have any changes to the CaveMan numerical models. CaveMan Enterprise represents, instead, a change from desktop-managed work- books to an enterprise framework, moving data management into coordinated databases and porting the numerical modeling codes into the Python programming language. This document provides a report of the code validation and verification testing.

  5. HyRAM (Hydrogen Risk Assessment Models) v. 1.0

    SciTech Connect

    Groth, Katrina M.; Hecht, Ethan S.; Reynolds, John T.; Blaylock, Myra L.; Ekoto, Isaac W.; Walkup, Gregory W.

    2016-02-17

    HyRAM is a software toolkit for conducting quantitative risk assessment (QRA) and consequence modeling for hydrogen infrastructure and transportation systems. HyRAM contains validated, simplified hydrogen behavior models, a standardized QRA approach, and engineering models and generic data relevant to hydrogen installations. HyRAM 1.0 was developed by Sandia National Laboratories for the U. S. Department of Energy to increase access to technical data about hydrogen and to enable the use of that data to support development and revision of national and international codes and standards with risk assessment and consequence modeling. The HyRAM toolkit integrates analytical and probabilistic models for quantifying accident scenarios, predicting physical effects, and characterizing the impact of hydrogen hazards (including thermal effects from jet fires and overpressure effects from deflagrations in confined areas) on people and structures. HyRAM incorporates generic probabilities for equipment failures for nine types of components, and probabilistic models for the impact of heat flux on humans and structures, with computationally and experimentally validated analytical first order models of hydrogen release and flame physics. Version 1 can be used to quantify the risk and consequences associated with gaseous hydrogen releases from user-defined hydrogen installations.

  6. Steady State Sputtering Yields and Surface Compositions of Depleted Uranium and Uranium Carbide bombarded by 30 keV Gallium or 16 keV Cesium Ions.

    SciTech Connect

    Siekhaus, W. J.; Teslich, N. E.; Weber, P. K.

    2014-10-23

    Depleted uranium that included carbide inclusions was sputtered with 30-keV gallium ions or 16-kev cesium ions to depths much greater than the ions’ range, i.e. using steady-state sputtering. The recession of both the uranium’s and uranium carbide’s surfaces and the ion corresponding fluences were used to determine the steady-state target sputtering yields of both uranium and uranium carbide, i.e. 6.3 atoms of uranium and 2.4 units of uranium carbide eroded per gallium ion, and 9.9 uranium atoms and 3.65 units of uranium carbide eroded by cesium ions. The steady state surface composition resulting from the simultaneous gallium or cesium implantation and sputter-erosion of uranium and uranium carbide were calculated to be U₈₆Ga₁₄, (UC)₇₀Ga₃₀ and U₈₁Cs₉, (UC)₇₉Cs₂₁, respectively.

  7. Inftared study of the interaction between proton donors and 1,10-phenanthroline derivatives

    NASA Astrophysics Data System (ADS)

    Siegel, G. G.; Zeegers-Huyskens, Th.

    1989-01-01

    The hydrogen bond complexes between 1,10-phenanthroline derivatives (bathocuproine, neo-cuproine and bathophenanthroline) and phenols have been investigated by i.r. spectrometry. The presence of two adjacent nitrogen atoms influences the thermodynamic and spectroscopic properties to a great extent. Comparison with recent results suggests that the 1,10-phenanthroline derivatives cannot be considered as "proton sponges".

  8. 32 CFR 1636.4 - Basis for classification in Class 1-0.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 6 2010-07-01 2010-07-01 false Basis for classification in Class 1-0. 1636.4 Section 1636.4 National Defense Other Regulations Relating to National Defense SELECTIVE SERVICE SYSTEM CLASSIFICATION OF CONSCIENTIOUS OBJECTORS § 1636.4 Basis for classification in Class 1-0. (a) A registrant...

  9. 45 CFR 1206.1-10 - Modification of procedures by consent.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 45 Public Welfare 4 2011-10-01 2011-10-01 false Modification of procedures by consent. 1206.1-10 Section 1206.1-10 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE GRANTS AND CONTRACTS-SUSPENSION AND TERMINATION AND DENIAL OF APPLICATION FOR REFUNDING Suspension and Termination...

  10. Anomaly of strings of 6d {N}=(1,0) theories

    NASA Astrophysics Data System (ADS)

    Shimizu, Hiroyuki; Tachikawa, Yuji

    2016-11-01

    We obtain the anomaly polynomial of strings of general 6d {N}=(1,0) theories in terms of anomaly inflow. Our computation sheds some light on the reason why the simplest 6d {N}=(1,0) theory has E 8 flavor symmetry, and also partially explains a curious numerology in F-theory.

  11. Detection of 1 - 100 keV x-rays from high intensity, 500 fs laser- produced plasmas using charge-coupled devices

    SciTech Connect

    Dunn, J.; Young, B.K.F.; Conder, A.D.; Stewart, R.E.

    1996-01-01

    We describe a compact, vacuum compatible, large format, charge- coupled device (CCD) camera for scientific imaging and detection of 1- 100 keV x rays in experiments at LLNL JANUS-1ps laser. A standard, front-illuminated, multi-pin phase device with 250 k electron full well capacity, low dark current (10 pA/cm{sup 2} at 20 C) and low read noise (5 electron rms) is cooled to -35 C to give the camera excellent 15-bit dynamic range and signal-to-noise response. Intensity and x-ray energy linear response were determined for optical and x-ray (<65 keV) photons and are in excellent agreement. Departure from linearity was less than 0.7%. Inherent linearity and energy dispersive characteristics of CCD cameras are well suited for hard x-ray photon counting. X-rays absorbed within the depletion and field-free regions can be distinguished by studying the pulse height spectrum. Results are presented for the detection of 1-100 keV Bremsstrahlung continuum, K-shell and L-shell fluorescence spectra emitted from high intensity (10{sup 18}W cm{sup -2}), 500 fs laser- produced plasmas.

  12. Studies of Transport Properties and Critical Temperature Suppression Mechanism in Yttrium BARIUM(2) COPPER(3) Oxygen(x) Thin Films Irradiated with 20 TO 120 KEV Electrons

    NASA Astrophysics Data System (ADS)

    Lin, Jiunn-Yuan

    1995-11-01

    We present comprehensive studies of the effects of 20 to 120 keV electron irradiation on rm YBa_2Cu_3O_{x} thin films. Above 60 keV, T_{c } of irradiated samples is suppressed accompanied by a significant increase in residual resistivity, while the carrier concentration remains relatively unchanged. The plane oxygen defects produced by irradiation are found to be responsible for T_{c} suppression. The II suppression mechanism is discussed within several theoretical frameworks. Though in qualitative agreement with d-wave pairing symmetry, our results show a T_{c} suppression rate three times as slow as predicted by the theory when resistivity data are used to extract the impurity scattering rate. Alternatively, phase fluctuations theory gives a qualitative description as well. The displacement energy of plane oxygen is found to be 8.3 eV, which corresponds to a threshold electron energy 58 keV. Finally, an empirical relation is proposed to describe the temperature dependence of the Hall coefficient.

  13. Elastic and inelastic processes in H{sup +}+C{sub 2}H{sub 6} collisions below the 10-keV regime

    SciTech Connect

    Suzuki, Reiko; Rai, Sachchida N.; Liebermann, Heinz-Peter; Buenker, Robert J.; Pichl, Lukas; Kimura, Mineo

    2005-11-15

    Charge-transfer processes in collisions of H{sup +} ions with C{sub 2}H{sub 6} molecules are investigated theoretically below 10-keV collision energies within a molecular representation. Converged total as well as differential cross sections are obtained in this energy range within a discrete basis of electronic states computed by ab inito methods. The present collision system suggests that the combination of the Demkov-type and Landau-Zener-type mechanisms primarily governs the scattering dynamics for the flux exit from the initial channel. The present charge-transfer cross sections determined are found to agree very well with all available experimental data below a few keV, but begin to deviate above 3 keV, in which the present results slowly decrease, while measurements stay nearly constant. From the study of the electronic state calculation, we provide some information on fragmented species, which should help shed some light on the fragmentation mechanism and process of C{sub 2}H{sub 6}{sup +} ions produced after charge transfer. In addition, the vibrational effect of the initial target to charge transfer is examined.

  14. The linker histone H1.0 generates epigenetic and functional intratumor heterogeneity*

    PubMed Central

    Burney, Matthew J.; Patel, Harshil; Henser-Brownhill, Tristan; Cohen, Ayelet-Hashahar Shapira; Li, Yilong; Ben-Hamo, Rotem; Nye, Emma; Spencer-Dene, Bradley; Chakravarty, Probir; Efroni, Sol; Matthews, Nik; Misteli, Tom; Meshorer, Eran; Scaffidi, Paola

    2016-01-01

    Tumors comprise functionally diverse subpopulations of cells with distinct proliferative potential. Here, we show that dynamic epigenetic states defined by the linker histone H1.0 determine which cells within a tumor can sustain the long-term cancer growth. Numerous cancer types exhibit high inter- and intratumor heterogeneity of H1.0, with H1.0 levels correlating with tumor differentiation status, patient survival and, at the single-cell level, cancer stem cell markers. Silencing of H1.0 promotes maintenance of self-renewing cells by inducing de-repression of megabase-sized gene domains harboring downstream effectors of oncogenic pathways. Self-renewing epigenetic states are not stable and re-expression of H1.0 in subsets of tumor cells establishes transcriptional programs that restrict cancer cell long-term proliferative potential and drive their differentiation. Our results uncover epigenetic determinants of tumor-maintaining cells. PMID:27708074

  15. DOSIMETRIC response of a REM-500 in low energy neutron fields typical of nuclear power plants.

    PubMed

    Aslam; Matysiak, W; Atanackovic, J; Waker, A J

    2012-06-01

    This study investigates the response of a REM-500 to assess neutron quality factor and dose equivalent in low energy neutron fields, which are commonly encountered in the workplace environment of nuclear power stations. The McMaster University 3 MV Van de Graaff accelerator facility was used to measure the response of the instrument in monoenergetic neutron fields in the energy range 51 to 727 keV by bombarding a thin LiF target with 1.93-2.50 MeV protons. The energy distribution of the neutron fields produced in the facility was measured by a (3)He filled gas ionization chamber. The MCA mode of the REM-500 instrument was used to collect lineal energy distributions at varying neutron energies and to calculate the frequency and dose-mean lineal energies. The effective quality factor, Q-, was also calculated using the values of Q(y)listed in the REM-500 operation manual and compared with those of ICRP 60. The authors observed a continuously increasing trend in y - F, y-D, and Q-with an increase in neutron energy. It is interesting to note that standard tissue equivalent proportional counters (TEPCs) filled with tissue equivalent(TE) gas give rise to a similar trend for these microdosimetric quantities of interest in the same energy range; however, the averages calculated in this study are larger by about 15%compared to a TEPC filled with propane-based TE gas probably because of the larger stopping power of protons in propane compared to TE gas. These somewhat larger event sizes did not result in any significant increase in the Q-compared to those obtained from a TEPC filled with TE gas and were found to be in good agreement with other measurements reported earlier at corresponding neutron energies. The instrument quality factor response, R(Q), defined as the ratio of measured quality factor to the calculated quality factor in an ICRU tissue sphere,was found to vary with neutron energy. The instrument response,R(Q), was ~0.6 at 727 keV, which deteriorates further to

  16. Properties of the 5{sup -} state at 839 keV in {sup 176}Lu and the s-process branching at A=176

    SciTech Connect

    Mohr, P.; Bisterzo, S.; Gallino, R.; Kaeppeler, F.; Kneissl, U.; Winckler, N.

    2009-04-15

    The s-process branching at mass number A=176 depends on the coupling between the high-K ground state and a low-lying low-K isomer in {sup 176}Lu. This coupling is based on electromagnetic transitions via intermediate states at higher energies. The properties of the lowest experimentally confirmed intermediate state at 839 keV are reviewed, and the transition rate between low-K and high-K states under stellar conditions is calculated on the basis of new experimental data for the 839-keV state. Properties of further candidates for intermediate states are briefly analyzed. It is found that the coupling between the high-K ground state and the low-K isomer in {sup 176}Lu is at least one order of magnitude stronger than previously assumed, leading to crucial consequences for the interpretation of the {sup 176}Lu/{sup 176}Hf pair as an s-process thermometer.

  17. Laboratory Measurements Compellingly Support a Charge-exchange Mechanism for the ’Dark Matter’ ~3.5 keV X-Ray Line

    NASA Astrophysics Data System (ADS)

    Shah, Chintan; Dobrodey, Stepan; Bernitt, Sven; Steinbrügge, René; Crespo López-Urrutia, José R.; Gu, Liyi; Kaastra, Jelle

    2016-12-01

    The reported observations of an unidentified X-ray line feature at ∼3.5 keV have driven a lively discussion about its possible dark matter origin. Motivated by this, we have measured the K-shell X-ray spectra of highly ionized bare sulfur ions following charge exchange with gaseous molecules in an electron beam ion trap, as a source of or a contributor to this X-ray line. We produced S16+ and S15+ ions and let them capture electrons in collision with those molecules with the electron beam turned off while recording X-ray spectra. We observed a charge-exchange-induced X-ray feature at the Lyman series limit (3.47 ± 0.06 keV). The inferred X-ray energy is in full agreement with the reported astrophysical observations and supports the novel scenario proposed by Gu et al.

  18. Covariance data for{sup 232}Th in the resolved resonance region from 0 to 4 keV

    SciTech Connect

    Leal, L. C.; Derrien, H.; Arbanas, G.; Larson, N. M.; Wiarda, D.

    2006-07-01

    This paper reports on the generation and testing of the covariance matrix associated with the resonance parameter evaluation for {sup 232}Th up to 4 keV. [1] Covariance data are required to correctly assess uncertainties in design parameters in nuclear applications. The error estimation of calculated quantities relies on the nuclear data uncertainty information available in the basic nuclear data libraries, such as the US Evaluated Nuclear Data Library, ENDF/B. Uncertainty files in the ENDF/B library are obtained from analysis of experimental data and are stored as variance and covariance data. In this paper, we address the generation of covariance data in the resonance region via the computer code SAMMY, which is used in the evaluation of experimental data in the resolved and unresolved resonance energy regions. The resolved resonance parameter covariance matrix for {sup 232}Th, obtained using the retroactive approach, is also presented here. (authors)

  19. 20-100 keV K(alpha) X-Ray Source Generation by Short Pulse High Intensity Lasers

    SciTech Connect

    Park, H-S; Koch, J A; Landen, O L; Phillips, T W; Goldsack, T

    2003-08-22

    We are studying the feasibility of utilizing K{alpha} x-ray sources in the range of 20 to 100 keV as a backlighters for imaging various stages of implosions and high areal density planar samples driven by the NIF laser facility. The hard x-ray K{alpha} sources are created by relativistic electron plasma interactions in the target material after a radiation by short pulse high intensity lasers. In order to understand K{alpha} source characteristics such as production efficiency and brightness as a function of laser parameters, we have performed experiments using the 10 J, 100 fs JanUSP laser. We utilized single-photon counting spectroscopy and x-ray imaging diagnostics to characterize the K{alpha} source. We find that the K{alpha} conversion efficiency from the laser energy is {approx} 3 x 10{sup -4}.

  20. Observation of the 22.5-keV resonance in (149)Sm by the nuclear lighthouse effect.

    PubMed

    Röhlsberger, R; Quast, K W; Toellner, T S; Lee, P L; Sturhahn, W; Alp, E E; Burkel, E

    2001-07-23

    We have observed coherent nuclear resonant scattering of synchrotron radiation at the 22.5-keV resonance of (149)Sm. High-speed rotational sample motion led to an angular deflection of the resonantly scattered radiation off the nonresonant primary beam. This allowed us to determine the resonance energy of the first excited nuclear level of (149)Sm to be 22496(4) eV. Because of the angular deflection of the resonant photons, time spectra of coherent nuclear resonant scattering can be recorded as a function of a spatial coordinate. Time resolutions of a few 10 ps can be expected, which are beyond the limits of existing x-ray detection schemes.

  1. Fully differential cross section for single ionization of helium by 1 KeV electrons in the eikonal approximation

    NASA Astrophysics Data System (ADS)

    Dey, R.; Roy, A. C.

    2009-07-01

    We report new results for fully differential cross sections for the single ionization of helium by 1 KeV electron impact at the ejection energy of 10 eV. Investigations have been made for both the scattering and perpendicular planes. The present calculation is based on the eikonal approximation due to Glauber. Here we have also incorporated the effect of classical post collision interaction (PCI) in the Glauber approximation (GA). A comparison is made of the present calculation with the results of other theoretical methods and the recent experiment [M. Dürr, C. Dimopoulou, B. Najjari, A. Dorn, K. Bartschat, I. Bray, D.V. Fursa, Z. Chen, D.H. Madison, J. Ullrich, Phys. Rev. A 77 (2008) 032717]. The Glauber results are in good agreement with the experiment in the scattering plane, but strong discrepancies are observed in the plane perpendicular to it. The effect of PCI is not substantial in the present kinematics.

  2. Instrumentation for measurement of in-flight annihilations of 130 keV antiprotons on thin target foils

    NASA Astrophysics Data System (ADS)

    Todoroki, K.; Barna, D.; Hayano, R. S.; Aghai-Khozani, H.; Sótér, A.; Corradini, M.; Leali, M.; Lodi-Rizzini, E.; Mascagna, V.; Venturelli, L.; Prest, V.; Vallazza, L.; De Salvador, D.; Hori, M.

    2016-11-01

    We describe the instrumentation for an experiment to measure the cross sections of antiprotons with kinetic energies of 130±10 keV annihilating on carbon, palladium, and platinum target foils of sub-100 nm thicknesses. A 120 ns long pulsed beam containing 105 -106 antiprotons was allowed to traverse the foils, and the signal annihilations that resulted from this were isolated using a time-of-flight method. Backgrounds arose from Rutherford scattering of the antiprotons off the target foils, their annihilations in the target chamber walls, and π → μ → e decay of the charged pions that emerged from the annihilations. Some antiprotons slowed down and annihilated in the contamination on the target surfaces. This reduced the signal-to-background ratio of the measurement.

  3. Differential cross sections for the single ionization of H2 by 75 keV proton impact

    NASA Astrophysics Data System (ADS)

    Igarashi, A.; Gulyás, L.

    2017-02-01

    We have calculated the double and triple differential cross sections for electron ejection with energy of 14.6 eV in single ionization of H2 by 75 keV proton impact. A molecular version of the continuum distorted wave-eikonal initial state approach is applied, where the interaction between the projectile and the residual molecular ion is considered more properly than in previous applications of the method. For triple differential cross sections, the present results are in better agreement with the experimental data than those of other descriptions when large momentum transfer values are considered. For double differential cross sections the experimental data are reproduced quite well for both coherent and incoherent proton beams.

  4. Experimental observations of Z-dependence of saturation thickness of 662 keV gamma rays in metals and glasses

    NASA Astrophysics Data System (ADS)

    Ravindraswami, K.; Kiran, K. U.; Eshwarappa, K. M.; Somashekarappa, H. M.

    2013-11-01

    In this paper the energy, intensity and angular distributions of multiple scattering of 662 keV gamma photons, emerging from targets of aluminium, copper, iron and glass samples are studied as a function of target thickness. An intense collimated beam obtained from a 137Cs source of 5.8 mCi is allowed to impinge on samples of varying thickness. The scattered photons are detected by a properly shielded 76 mm × 76 mm NaI (Tl) scintillation detector. In Compton scattering experiments, it is observed that the number of multiple backscattered photons increase with an increase in target thickness and become almost constant for particular target thickness called saturation thickness. The saturation thickness decreases with increasing atomic number. The multiple scattering, an interfering background noise in Compton profile, has been successfully used to assign effective atomic number (Z eff ) to composite materials. The experimental results are compared with the Monte Carlo calculations using Monte Carlo nuclear particle code.

  5. CO2 synthesis in solid CO by Lyman-α photons and 200 keV protons

    NASA Astrophysics Data System (ADS)

    Loeffler, M. J.; Baratta, G. A.; Palumbo, M. E.; Strazzulla, G.; Baragiola, R. A.

    2005-05-01

    We have studied the synthesis of carbon dioxide from solid carbon monoxide at 16 K induced by photolysis with Lyman-α photons and by irradiation with 200 keV protons to quantitatively compare the effects of photolysis and ion irradiation on CO ice and to determine the importance of these processes in interstellar ice grains. The CO and CO{2} concentrations during irradiation of an initially pure CO film evolve with fluence to a saturation value, a behaviour that is explained by a two-state model. Our results indicate that the initial CO{2} production rates for both radiation processes are similar when normalized to the absorbed energy and that the solid CO{2} abundance observed in the interstellar ices cannot be explained only by radiolysis and photolysis of pure solid CO.

  6. Decrease of keV electron and ion fluxes in the dayside magnetosphere during the early phase of magnetospheric disturbances

    NASA Technical Reports Server (NTRS)

    Hultqvist, B.; Aparicio, B.; Borg, H.; Arnoldy, R.; Moore, T. E.

    1981-01-01

    It is shown that a decrease of the keV particle fluxes in the dayside magnetosphere near the geosynchronous orbit is characteristic of the first several hours of magnetospheric disturbances. After some hours newly injected plasma from the nightside reaches the 'evacuated' regions of the dayside magnetosphere and strong flux increases are observed. The 'evacuation' of the dayside magnetosphere is interpreted in terms of a change in the convection pattern associated with an increase of the large scale electric field at the onset of the disturbance. The model presented is capable of accommodating all characteristics of the observational data, such as the temporal and spatial distributions, energy and pitch angle characteristics, and differences between electrons and protons.

  7. Evaluation of the 1077 keV γ-ray emission probability from 68Ga decay

    NASA Astrophysics Data System (ADS)

    Huang, Xiao-Long; Jiang, Li-Yang; Chen, Xiong-Jun; Chen, Guo-Chang

    2014-04-01

    68Ga decays to the excited states of 68Zn through the electron capture decay mode. New recommended values for the emission probability of 1077 keV γ-ray given by the ENSDF and DDEP databases all use data from absolute measurements. In 2011, JIANG Li-Yang deduced a new value for 1077 keV γ-ray emission probability by measuring the 69Ga(n,2n) 68Ga reaction cross section. The new value is about 20% lower than values obtained from previous absolute measurements and evaluations. In this paper, the discrepancies among the measurements and evaluations are analyzed carefully and the new values are re-recommended. Our recommended value for the emission probability of 1077 keV γ-ray is (2.72±0.16)%.

  8. keV sterile neutrino dark matter and low scale leptogenesis

    NASA Astrophysics Data System (ADS)

    Kang, Sin Kyu; Patra, Ayon

    2016-10-01

    We consider a simple extension of the Standard Model to consistently explain the observation of a peak in the galactic X-ray spectrum at 3.55 keV, the light neutrino masses, and the baryon asymmetry of the universe. The baryon asymmetry is generated through leptogenesis, the lepton asymmetry being generated by the decay of a heavy neutrino with a TeV mass scale. The extra singlet fermion introduced in the model can be identified as a dark matter candidate with a mass of 7.1 keV. It decays with a lifetime much larger than the age of the universe, producing a final state photon. The Yukawa interactions between the extra singlet neutrino and a heavier right-handed neutrino play a crucial role in simultaneously achieving low-scale leptogenesis and the relic density of the keV dark matter candidate.

  9. Quark nugget dark matter: no contradiction with 511 keV line emission from dwarf galaxies

    NASA Astrophysics Data System (ADS)

    Lawson, Kyle; Zhitnitsky, Ariel

    2017-02-01

    The observed galactic 511 keV line has been interpreted in a number of papers as a possible signal of dark matter annihilation within the galactic bulge. If this is the case then it is possible that a similar spectral feature may be observed in association with nearby dwarf galaxies. These objects are believed to be strongly dark matter dominated and present a relatively clean observational target. Recently INTEGRAL observations have provided new constraints on the 511 keV flux from nearby dwarf galaxies [1] motivating further investigation into the mechanism by which this radiation may arise. In the model presented here dark matter in the form of heavy quark nuggets produces the galactic 511 keV emission line through interactions with the visible matter. It is argued that this type of interaction is not strongly constrained by the flux limits reported in [2].

  10. Combination of CN(1-0), HCN(1-0), and HNC(1-0): A possible indicator for a high-mass star formation sequence in the Milky Way

    NASA Astrophysics Data System (ADS)

    Han, X. H.; Zhou, J. J.; Wang, J. Z.; Esimbek, J.; Zhang, J. S.; Wang, N.

    2015-04-01

    Context. CN, HCN, and HNC have been used to discuss the star formation sequence in galaxies, but recent studies of large samples involving these lines did not yet provide convincing results. Aims: We intend to determine whether the global line ratios CN/HCN, CN/HNC, and HCN/HNC can be used to trace the high-mass star formation sequence in the Milky Way. Methods: We performed map observations of CN(1-0), HCN(1-0), and HNC(1-0) toward 38 high-mass star-forming regions, which includes high-mass starless cores (HMSC), high-mass protostars (HMPO), UCHII (ultra-compact HII) and normal HII regions. We identified the molecular clumps associated with them, and removed the clumps that were affected by environment. We averaged all the detected emission from each clump to obtain global line ratios and investigated their variations with the evolutionary stages of high-mass star-forming clumps. Results: The global line ratios of ICN/IHNC and IHCN/IHNC for HMSC clumps (HMSCCs), HMPO clumps (HMPOCs), UCHII region clumps (UCHIICs), and HII region clumps display an increasing trend. We tentatively divide the star-forming regions into two types. Type 1 sources include HMSCCs and HMPOCs that are not associated with external 20 cm continuum emission. Type 2 sources include all UCHIICs and HIICs. Our analysis shows that the ICN/IHNC and IHCN/IHNC line ratios can trace the evolution from type 1 to type 2 well. The same method may be used to study the evolution of external galaxies. Conclusions: ICN/IHNC and IHCN/IHNC appear to be good tracers for the evolution of high-mass star-forming regions in the Milky Way. Appendices are available in electronic form at http://www.aanda.org

  11. Structural properties of platinum(II) biphenyl complexes containing 1,10-phenanthroline derivatives

    NASA Astrophysics Data System (ADS)

    Rillema, D. Paul; Cruz, Arvin J.; Tasset, Brandon J.; Moore, Curtis; Siam, Khamis; Huang, Wei

    2013-06-01

    Seven platinum(II) complexes formulated as Pt(bph)L, where bph is the 2,2'-biphenyl dianion and L = 4-methyl-1,10-phenanthroline (4-Mephen), 5-methyl-1,10-phenanthroline (5-Mephen), 5-chloro-1,10-phenanthroline (5-Clphen), 5,6-dimethyl-1,10-phenanthroline (5,6-Me2phen), 4,7-dimethyl-1,10-phenanthroline (4,7-Me2phen), 4,7-diphenyl-1,10-phenanthroline (4,7-Ph2phen) and 3,4,7,8-tetramethyl-1,10-phenanthroline (3,4,7,8-Me4phen) are reported. Protons attached to the phen ligand resonate downfield from those attached to the bph ligand and two proton signals are split by interaction with 195Pt. Pt(bph)(3,4,7,8-Me4phen), Pt(bph)(4,7-Me2phen), Pt(bph)(5,6-Me2phen), Pt(bph)(4,7-Ph2phen) and Pt(bph)(5-Mephen) crystallize in the space groups Pna21, P21/n, P21/c, P - 1 and Pca21, respectively. The structures of the complexes deviate from true planarity and divide themselves into two groups where the bph and phen ligands cross in an X configuration or bow out in a butterfly (B) configuration. Circular dichroism revealed two different spectra with respect to the X and B configurations.

  12. 3.55 keV line in minimal decaying dark matter scenarios

    SciTech Connect

    Arcadi, Giorgio; Covi, Laura; Dradi, Federico

    2015-07-20

    We investigate the possibility of reproducing the recently reported 3.55 keV line in some simple decaying dark matter scenarios. In all cases a keV scale decaying DM is coupled with a scalar field charged under SM gauge interactions and thus capable of pair production at the LHC. We will investigate how the demand of a DM lifetime compatible with the observed signal, combined with the requirement of the correct DM relic density through the freeze-in mechanism, impacts the prospects of observation at the LHC of the decays of the scalar field.

  13. Data Evaluation Acquired Talys 1.0 Code to Produce 111In from Various Accelerator-Based Reactions

    NASA Astrophysics Data System (ADS)

    Alipoor, Zahra; Gholamzadeh, Zohreh; Sadeghi, Mahdi; Seyyedi, Solaleh; Aref, Morteza

    The Indium-111 physical-decay parameters as a β-emitter radionuclide show some potential for radiodiagnostic and radiotherapeutic purposes. Medical investigators have shown that 111In is an important radionuclide for locating and imaging certain tumors, visualization of the lymphatic system and thousands of labeling reactions have been suggested. The TALYS 1.0 code was used here to calculate excitation functions of 112/114-118Sn+p, 110Cd+3He, 109Ag+3He, 111-114Cd+p, 110/111Cd+d, 109Ag+α to produce 111In using low and medium energy accelerators. Calculations were performed up to 200 MeV. Appropriate target thicknesses have been assumed based on energy loss calculations with the SRIM code. Theoretical integral yields for all the latter reactions were calculated. The TALYS 1.0 code predicts that the production of a few curies of 111In is feasible using a target of isotopically highly enriched 112Cd and a proton energy between 12 and 25 MeV with a production rate as 248.97 MBq·μA-1 · h-1. Minimum impurities shall be produced during the proton irradiation of an enriched 111Cd target yielding a production rate for 111In of 67.52 MBq· μA-1 · h-1.

  14. Optical Positions of ICRF Sources from CTIO 1.0M Data

    DTIC Science & Technology

    2015-01-01

    ABSTRACT As part of the USNO radio-optical reference frame link project, data were taken with the CTIO 1.0 m telescope in 2009. First position...ABSTRACT As part of the USNO radio-optical reference frame link project, data were taken with the CTIO 1.0 m telescope in 2009. First position...Yale 1.0 meter telescope and Y4K camera which were used for this study. TABLE 1. INSTRUMENT PROPERTIES aperture 1000 mm focal ratio f/10 Cass. filters

  15. DFT structural investigation on Fe(1,10-phenanthroline){sub 2} (NCS){sub 2} spin crossover molecule

    SciTech Connect

    Chiş, V.; Isai, R.; Droghetti, A.; Rungger, I.; Sanvito, S.; Morari, C.

    2013-11-13

    Understanding the coupling of spin crossover molecules to metallic surfaces is a key ingredient for harnessing of their remarkable features for future spintronics applications. Here we investigate the structural and electronic properties of deformed Fe(1,10-phenanthroline){sub 2} (NCS){sub 2} molecules, mimicking the possible effects arising from the interaction with a metallic substrate. We find a relatively large structural flexibility for this molecule, accompanied by small changes in their total energy. This suggests that the spin crossover activity can be modulated by the interaction with the substrate.

  16. First Observation of a (1,0) Mode Frequency Shift of an Electron Plasma at Antiproton Beam Injection

    NASA Astrophysics Data System (ADS)

    Kuroda, N.; Mohri, A.; Torii, H. A.; Nagata, Y.; Shibata, M.

    2014-07-01

    The frequency shift of the center-of-mass oscillation, known as the (1,0) mode, of a trapped electron plasma and, furthermore, its time evolution were observed during the cooling of an injected antiproton beam for the first time. Here, antiprotons mixed with the electrons did not follow faster electron oscillations but contributed to the modification of the effective potential. The time evolution of the plasma temperature, deduced from the frequency shift of the excited (3,0) mode, suggested that there was an abnormal energy deposition of the antiproton beam in the electron plasma before thermalization.

  17. Energy

    DTIC Science & Technology

    2003-01-01

    Canada, Britain, and Spain. We found that the energy industry is not in crisis ; however, U.S. government policies, laws, dollars, and even public...CEIMAT (Centro de Investagaciones Energeticas , Medioambeintales y Tecnologicas) Research and development Page 3 of 28ENERGY 8/10/04http://www.ndu.edu...procurement or storage of standard, common use fuels. NATURAL GAS Natural gas, abundant globally and domestically, offers energy versatility among

  18. Tier I Rice Model - Version 1.0 - Guidance for Estimating Pesticide Concentrations in Rice Paddies

    EPA Pesticide Factsheets

    Describes a Tier I Rice Model (Version 1.0) for estimating surface water exposure from the use of pesticides in rice paddies. The concentration calculated can be used for aquatic ecological risk and drinking water exposure assessments.

  19. Indoor Semi-volatile Organic Compounds (i-SVOC) Version 1.0

    EPA Pesticide Factsheets

    i-SVOC Version 1.0 is a general-purpose software application for dynamic modeling of the emission, transport, sorption, and distribution of semi-volatile organic compounds (SVOCs) in indoor environments.

  20. 32 CFR 1636.5 - Exclusion from Class 1-A-0 and Class 1-0.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... CLASSIFICATION OF CONSCIENTIOUS OBJECTORS § 1636.5 Exclusion from Class 1-A-0 and Class 1-0. A registrant shall... any form (a selective objection). If a registrant objects to war in any form, but also believes in...

  1. 30 CFR 57.22236 - Actions at 1.0 percent methane (VI mines).

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... percent methane (VI mines). If methane reaches 1.0 percent in the mine atmosphere, all persons other than competent persons necessary to make ventilation changes shall be withdrawn from affected areas until...

  2. 30 CFR 57.22236 - Actions at 1.0 percent methane (VI mines).

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... percent methane (VI mines). If methane reaches 1.0 percent in the mine atmosphere, all persons other than competent persons necessary to make ventilation changes shall be withdrawn from affected areas until...

  3. 30 CFR 57.22236 - Actions at 1.0 percent methane (VI mines).

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... percent methane (VI mines). If methane reaches 1.0 percent in the mine atmosphere, all persons other than competent persons necessary to make ventilation changes shall be withdrawn from affected areas until...

  4. 32 CFR 1636.5 - Exclusion from Class 1-A-0 and Class 1-0.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... be excluded from Class 1-A-0 or Class 1-0: (a) Who asserts beliefs which are of a religious, moral or... participation in war does not rest at all upon moral, ethical, or religious principle, but instead rests...

  5. Tables and graphs of photon-interaction cross sections from 0. 1 keV to 100 MeV derived from the LLL evaluated-nuclear-data library

    SciTech Connect

    Plechaty, E.F.; Cullen, D.E.; Howerton, R.J.

    1981-11-11

    Energy-dependent evaluated photon interaction cross sections and related parameters are presented for elements H through Cf(Z = 1 to 98). Data are given over the energy range from 0.1 keV to 100 MeV. The related parameters include form factors and average energy deposits per collision (with and without fluorescence). Fluorescence information is given for all atomic shells that can emit a photon with a kinetic energy of 0.1 keV or more. In addition, the following macroscopic properties are given: total mean free path and energy deposit per centimeter. This information is derived from the Livermore Evaluated-Nuclear-Data Library (ENDL) as of October 1978.

  6. UT40 STARS Reuse Concept. Volume 1. Conceptual Framework for Reuse Process Version 1.0

    DTIC Science & Technology

    1992-02-12

    1 TASK: UT40 UT40- CDRL:040402/14/92 AD-A247 267 STARS Reuse Concept 24 t i Vol u me I - Conceptual Framework for Reuse Process Version 1.0 Informal...3For The SOFTWARE TECHNOLOGY FOR ADAPTABLE, RELIABLE SYSTEMS 3 (STARS) STARS Reuse Concepts Volume I - Conceptual Framework for Reuse Process -ccesion...STARS Reuse Concepts Volume I - Conceptual Framework for Reuse Processes I Version 1.0 Approvals: Boeing Reuse Technical Lead Margaret Davis Date IBM

  7. 1-to 10-keV x-ray backlighting of annular wire arrays on the Sandia Z-machine using bent-crystal imaging techniques.

    SciTech Connect

    Rambo, Patrick K.; Wenger, David Franklin; Bennett, Guy R.; Sinars, Daniel Brian; Smith, Ian Craig; Porter, John Larry, Jr.; Cuneo, Michael Edward; Rovang, Dean Curtis; Anderson, Jessica E.

    2003-07-01

    Annular wire array implosions on the Sandia Z-machine can produce >200 TW and 1-2 MJ of soft x rays in the 0.1-10 keV range. The x-ray flux and debris in this environment present significant challenges for radiographic diagnostics. X-ray backlighting diagnostics at 1865 and 6181 eV using spherically-bent crystals have been fielded on the Z-machine, each with a {approx}0.6 eVspectral bandpass, 10 {micro}m spatial resolution, and a 4 mm by 20mm field of view. The Z-Beamlet laser, a 2-TW, 2-kJ Nd:glass laser({lambda} = 527 nm), is used to produce 0.1-1 J x-ray sources for radiography. The design, calibration, and performance of these diagnostics is presented.

  8. VO2@RER1.0: a novel submaximal cardiopulmonary exercise index.

    PubMed

    Chin, Clifford; Kazmucha, Jeffrey; Kim, Nancy; Suryani, Reny; Olson, Inger

    2010-01-01

    Maximal oxygen consumption (VO2max) is the "gold standard" by which to assess functional capacity; however, it is effort dependent. VO2@RER1.0 is defined when VO2 = VCO2. Between December 22, 1997 and November 9, 2004, 305 pediatric subjects underwent cycle ergometer cardiopulmonary exercise testing, exercised to exhaustion, and reached a peak respiratory exchange ratio > or = 1.10. Group 1 subjects achieved a peak VO2 > or = 80% of predicted VO2max; group 2 subjects achieved a peak VO2 < or = 60% of predicted VO2max; and group 3 subjects achieved a peak VO2 between 61 and 79% of predicted VO2max. Linear regression analysis was performed for VO2@RER1.0 as a function of predicted VO2 for group 1 subjects. A -2 SD regression line and equation was created. VO2@RER1.0 data from groups 2 and 3 were plotted onto the normative graph. Contingency table and relative-risk analysis showed that an abnormal VO2@RER1.0 predicted an abnormal peak VO2(positive-predictive value 83%, negative-predictive value 85%, sensitivity 84%, and specificity 84%). VO2@RER1.0 is a highly sensitive, specific, and predictive submaximal index of functional capacity. This submaximal index is easy to identify without subjectivity. This index may aid in the evaluation of subjects who cannot exercise to maximal parameters.

  9. A gas scintillation proportional detector to search for 17 keV neutrinos

    SciTech Connect

    Okx, W.J.C.; Bom, V.R.; Eijk, C.W.E. van; Hollander, R.W. )

    1993-08-01

    Evidence for the existence of a 17 keV neutrino was first reported in 1985. Since then many experiments have been performed with contradicting results. In this paper the authors describe an experiment with a new approach to the problem by the introduction of a Gas Scintillation Proportional Detector.

  10. A study on the microstructural parameters of 550 keV electron irradiated Lexan polymer films

    SciTech Connect

    Hareesh, K.; Pramod, R.; Petwal, V. C.; Dwivedi, Jishnu; Sangappa; Sanjeev, Ganesh

    2012-06-05

    Lexan polymer films irradiated with 550 keV Electron Beam (EB) were characterized using Wide Angle Xray Scattering (WAXS) data to study the microstructural parameters. The crystal imperfection parameters like crystal size , lattice strain (g in %) and enthalpy ({alpha}) have been determined by Line Profile Analysis (LPA) using Fourier method of Warren.

  11. Lifetime measurement of the 6792 keV state in {sup 15}O, important for the astrophysical S factor extrapolation in {sup 14}N(p,{gamma}){sup 15}O

    SciTech Connect

    Schuermann, D.; Kunz, R.; Lingner, I.; Rolfs, C.; Schuemann, F.; Strieder, F.; Trautvetter, H.-P.

    2008-05-15

    We report on a new lifetime measurement of the E{sub x}=6792 keV state in {sup 15}O via the Doppler-shift attenuation method at the E=259 keV resonance in the reaction {sup 14}N(p,{gamma}){sup 15}O. This subthreshold state is of particular importance for the determination of the ground state astrophysical S factor of {sup 14}N(p,{gamma}){sup 15}O at stellar energies. The measurement technique has been significantly improved over that used in previous work. The conclusion of a finite lifetime drawn there cannot be confirmed with the present data. In addition, the lifetimes of the two states at E{sub x}=5181 and 6172 keV have been measured with the same technique in order to verify the experimental method. We observe an attenuation factor F({tau})>0.98 for the E{sub x}=6172 and 6792 keV states, respectively, corresponding to {tau}<0.77 fs. The attenuation factor for the E{sub x}=5181 keV state results in F({tau})=0.78{+-}0.02 corresponding to {tau}=8.4{+-}1.0 fs, which is in excellent agreement with literature.

  12. A new grating X-ray spectrometer for 2-4 keV enabling a separate observation of In-Lβ and Sn-Lα emissions of indium tin oxide.

    PubMed

    Terauchi, Masami; Takahashi, Hideyuki; Handa, Nobuo; Murano, Takanori; Koike, Masato; Kawachi, Tetsuya; Imazono, Takashi; Hasegawa, Noboru; Koeda, Masaru; Nagano, Tetsuya; Sasai, Hiroyuki; Oue, Yuki; Yonezawa, Zeno; Kuramoto, Satoshi

    2013-06-01

    A new multilayer-coated varied line-spaced grating, JS4000, was fabricated and tested for extending the upper limit of a grating X-ray spectrometer for electron microscopy. This grating was designed for 2-3.8 keV at a grazing incidence angle of 1.35°. It was revealed that this new multilayer structure enables us to take soft-X-ray emission spectra continuously from 1.5 to 4.3 keV at the same optical setting. The full-width at half maximum of Te-L(α1,2) (3.8 keV) emission peak was 27 eV. This spectrometer was applied to indium tin oxide particles and clearly resolved Sn-L(α) (3444 eV) and In-L(β1) (3487 eV) peaks, which could not be resolved by a widely used energy-dispersive X-ray spectrometer.

  13. [Synthesis, characterization and fluorescence properties of binary and ternary rare earth complexes with N-phenylanthranilic acid and 1, 10-phenanthroline].

    PubMed

    Wang, Xi-gui; Wu, Hong-ying; Zhao, Hui; Zhao, Si-qin; Weng, Shi-fu; Wu, Jin-guang

    2005-03-01

    Some novel binary and ternary complexes of rare earth (Tb) with N-phenylanthranilic acid and 1,10-phenanthroline were synthesized and their compositions were characterized by elemental analysis. The compositions of the complexes have been confirmed to be TbL3. 4H2O and TbL3 phen.2H20 (L: N-phenylanthranilic acid, phen: 1;10-phenanthroline). The spectroscopic properties of the complexes were discussed. The result shows that the luminescence intensities of binary and ternary complexes were decreased by N-phenylanthranilic acid and 1,10-phenanthroline. It is indicated that the intensity of Tb depends on the structure of ligands. The structure, energy transfer and energy matching were studied, and it is concluded that the structure of complex affects the luminescence properties of the complexes.

  14. Measurement of the -3keV Resonance in the Reaction C13(α,n)O16 of Importance in the s-Process

    NASA Astrophysics Data System (ADS)

    La Cognata, M.; Spitaleri, C.; Trippella, O.; Kiss, G. G.; Rogachev, G. V.; Mukhamedzhanov, A. M.; Avila, M.; Guardo, G. L.; Koshchiy, E.; Kuchera, A.; Lamia, L.; Puglia, S. M. R.; Romano, S.; Santiago, D.; Spartà, R.

    2012-12-01

    The C13(α,n)O16 reaction is the neutron source for the main component of the s-process, responsible for the production of most nuclei in the mass range 90≲A≲204. It is active inside the helium-burning shell in asymptotic giant branch stars, at temperatures ≲108K, corresponding to an energy interval where the C13(α,n)O16 is effective from 140 to 230 keV. In this region, the astrophysical S(E)-factor is dominated by the -3keV subthreshold resonance due to the 6.356 MeV level in O17, giving rise to a steep increase of the S(E)-factor. Notwithstanding that it plays a crucial role in astrophysics, no direct measurements exist inside the s-process energy window. The magnitude of its contribution is still controversial as extrapolations, e.g., through the R matrix and indirect techniques, such as the asymptotic normalization coefficient (ANC), yield inconsistent results. The discrepancy amounts to a factor of 3 or more right at astrophysical energies. Therefore, we have applied the Trojan horse method to the C13(Li6,nO16)d quasifree reaction to achieve an experimental estimate of such contribution. For the first time, the ANC for the 6.356 MeV level has been deduced through the Trojan horse method as well as the n-partial width, allowing to attain an unprecedented accuracy in the C13(α,n)O16 study. Though a larger ANC for the 6.356 MeV level is measured, our experimental S(E)-factor agrees with the most recent extrapolation in the literature in the 140-230 keV energy interval, the accuracy being greatly enhanced thanks to this innovative approach.

  15. Accretion Properties of a Sample of Hard X-Ray (<60 keV) Selected Seyfert 1 Galaxies

    NASA Astrophysics Data System (ADS)

    Wang, J.; Mao, Y. F.; Wei, J. Y.

    2009-02-01

    We examine the accretion properties in a sample of 42 hard (3-60 keV) X-ray selected nearby broad-line active galactic nuclei (AGNs). The energy range in the sample is harder than that usually used in similar previous studies. These AGNs are mainly complied from the RXTE All Sky Survey, and complemented by the released INTEGRAL AGN catalog. The black hole masses, bolometric luminosities of AGN, and Eddington ratios are derived from their optical spectra in terms of the broad Hβ emission line. The tight correlation between the hard X-ray (3-20 keV) and bolometric/line luminosity is well identified in our sample. Also identified is a strong inverse Baldwin relationship of the Hβ emission line. In addition, all of these hard X-ray AGNs are biased toward luminous objects with a high Eddington ratio (mostly between 0.01 and 0.1) and a low column density (<1022 cm-2), which is most likely due to the selection effect of the surveys. The hard X-ray luminosity is consequently found to be strongly correlated with the black hole mass. We believe the sample completeness will be improved in the next few years by the ongoing Swift and the International Gamma-Ray Astrophysics Laboratory missions, and by the next advanced missions, such as NuSTAR, Simbol-X, and NeXT. Finally, the correlation between RFe (= optical Fe II/Hβ) and disk temperature as assessed by T vprop (L/L Edd)M -1 BH leads us to suggest that the strength of the Fe II emission is mainly determined by the shape of the ionizing spectrum.

  16. The effectiveness of monoenergetic neutrons at 565 keV in producing dicentric chromosomes in human lymphocytes at low doses.

    PubMed

    Schmid, E; Regulla, D; Guldbakke, S; Schlegel, D; Bauchinger, M

    2000-09-01

    The induction of dicentric chromosomes in human lymphocytes from one individual irradiated in vitro with monoenergetic neutrons at 565 keV was examined to provide additional data for an improved evaluation of neutrons with respect to radiation risk in radioprotection. The resulting linear dose-response relationship obtained (0.813 +/- 0.052 dicentrics per cell per gray) over the dose range of 0.0213-0.167 Gy is consistent with published results obtained for irradiation with neutrons from different sources and with different spectra at energies lower than 1000 keV. Comparing this value to previously published "average" dose-response curves obtained by different laboratories for (60)Co gamma rays and orthovoltage X rays resulted in maximum RBEs (RBE(m)) of about 37 +/- 8 and 16 +/- 4, respectively. However, when our neutron data were matched to low-LET dose responses that were constructed several years earlier for lymphocytes from the same individual, higher values of RBE(m) resulted: 76.0 +/- 29.5 for (60)Co gamma rays and 54.2 +/- 18.4 for (137)Cs gamma rays; differentially filtered 220 kV X rays produced values of RBE(m) between 20.3 +/- 2.0 or 37.0 +/- 7. 1. The results highlight the dependence of RBE(m) on the choice of low-LET reference radiation and raise the possibility that differential individual response to low-LET radiations may need to be examined more fully in this context.

  17. Production and Performance of the InFOCmicronS 20-40 keV Graded Multilayer Mirror

    NASA Technical Reports Server (NTRS)

    Berendse, F.; Owens, S. M.; Serlemitsos, P. J.; Tueller, J.; Chan, K.-W.; Soong, Y.; Krimm, H.; Baumgartner, W. H.; Tamura, K.; Okajima, T.; Tawara, Y.; White, Nicholas E. (Technical Monitor)

    2002-01-01

    The International Focusing Optics Collaboration for micron Crab Sensitivity (InFOC micronS) balloon-borne hard x-ray incorporates graded multilayer technology to obtain significant effective area at energies previously inaccessible to x-ray optics. The telescope mirror consists of 2040 segmented thin aluminum foils coated with replicated Pt/C multilayers. A sample of these foils was scanned using a pencil-beam reflectometer to determine, multilayer quality. The results of the reflectometer measurements demonstrate our capability to produce large quantity of foils while maintaining high-quality multilayers with a mean Nevot-Croce interface roughness of 0.5nm. We characterize the performance of the complete InFOC micronS telescope with a pencil beam raster scan to determine the effective area and encircled energy function of the telescope. The effective area of the complete telescope is 78, 42 and 22 square centimeters at 20 30 and 40 keV. respectively. The measured encircled energy fraction of the mirror has a half-power diameter of 2.0 plus or minus 0.5 arcmin (90% confidence). The mirror successfully obtained an image of the accreting black hole Cygnus X-1 during a balloon flight in July, 2001. The successful completion and flight test of this telescope demonstrates that graded-multilayer telescopes can be manufactured with high reliability for future x-ray telescope missions such as Constellation-X.

  18. Creep Properties of Sn-1.0Ag-0.5Cu Lead-Free Solder with Ni Addition

    NASA Astrophysics Data System (ADS)

    Che, F. X.; Zhu, W. H.; Poh, Edith S. W.; Zhang, X. R.; Zhang, Xiaowu; Chai, T. C.; Gao, S.

    2011-03-01

    In this work, tensile creep tests for Sn-1.0Ag-0.5Cu-0.02Ni solder have been conducted at various temperatures and stress levels to determine its creep properties. The effects of stress level and temperature on creep strain rate were investigated. Creep constitutive models (such as the simple power-law model, hyperbolic sine model, double power-law model, and exponential model) have been reviewed, and the material constants of each model have been determined based on experimental results. The stress exponent and creep activation energy have been studied and compared with other researchers' results. These four creep constitutive models established in this paper were then implemented into a user-defined subroutine in the ANSYS™ finite-element analysis software to investigate the creep behavior of Sn-1.0Ag-0.5Cu-0.02Ni solder joints of thin fine-pitch ball grid array (TFBGA) packages for the purpose of model comparison and application. Similar simulation results of creep strain and creep strain energy density were achieved when using the different creep constitutive models, indicating that the creep models are consistent and accurate.

  19. Study of 1–8 keV K-α x-ray emission from high intensity femtosecond laser produced plasma

    SciTech Connect

    Arora, V. Naik, P. A.; Chakera, J. A.; Bagchi, S.; Tayyab, M.; Gupta, P. D.

    2014-04-15

    We report an experimental study on the optimization of a laser plasma based x-ray source of ultra-short duration K-α line radiation. The interaction of pulses from a CPA based Ti:sapphire laser (10 TW, 45 fs, 10 Hz) system with magnesium, titanium, iron and copper solid target generates bright 1-8 keV K-α x-ray radiation. The x-ray yield was optimized with the laser pulse duration (at fixed fluence) which is varied in the range of 45 fs to 1.4 ps. It showed a maximum at laser pulse duration of ∼740 fs, 420 fs, 350 and 250 fs for Mg (1.3 keV), Ti (4.5 keV), Fe (6.4 keV) and Cu (8.05 keV) respectively. The x-ray yield is observed to be independent of the sign of the chirp. The scaling of the K-α yield (I{sub x} ∝ I{sub L}{sup β}) for 45 fs and optimized pulse duration were measured for laser intensities in the region of 3 × 10{sup 14} – 8 × 10{sup 17}. The x-ray yield shows a much faster scaling exponent β = 1.5, 2.1, 2.4 and 2.6 for Mg, Ti, Fe and Cu respectively at optimized pulse duration compared to scaling exponent of 0.65, 1.3, 1.5, and 1.7 obtained for 45 fs duration laser pulses. The laser to x-ray energy conversion efficiencies obtained for different target materials are η{sub Mg} = 1.2 × 10{sup −5}, η{sub Ti} = 3.1 × 10{sup −5}, η{sub Fe} = 2.7 × 10{sup −5}, η{sub Cu} = 1.9 × 10{sup −5}. The results have been explained from the efficient generation of optimal energy hot electrons at longer laser pulse duration. The faster scaling observed at optimal pulse duration indicates that the x-ray source is generated at the target surface and saturation of x-ray emission would appear at larger laser fluence. An example of utilization of the source for measurement of shock-wave profiles in a silicon crystal by time resolved x-ray diffraction is also presented.

  20. Assessment of radionuclide databases in CAP88 mainframe version 1.0 and Windows-based version 3.0.

    PubMed

    LaBone, Elizabeth D; Farfán, Eduardo B; Lee, Patricia L; Jannik, G Timothy; Donnelly, Elizabeth H; Foley, Trevor Q

    2009-09-01

    In this study the radionuclide databases for two versions of the Clean Air Act Assessment Package-1988 (CAP88) computer model were assessed in detail. CAP88 estimates radiation dose and the risk of health effects to human populations from radionuclide emissions to air. This program is used by several U.S. Department of Energy (DOE) facilities to comply with National Emission Standards for Hazardous Air Pollutants regulations. CAP88 Mainframe, referred to as version 1.0 on the U.S. Environmental Protection Agency Web site (http://www.epa.gov/radiation/assessment/CAP88/), was the very first CAP88 version released in 1988. Some DOE facilities including the Savannah River Site still employ this version (1.0) while others use the more user-friendly personal computer Windows-based version 3.0 released in December 2007. Version 1.0 uses the program RADRISK based on International Commission on Radiological Protection Publication 30 as its radionuclide database. Version 3.0 uses half-life, dose, and risk factor values based on Federal Guidance Report 13. Differences in these values could cause different results for the same input exposure data (same scenario), depending on which version of CAP88 is used. Consequently, the differences between the two versions are being assessed in detail at Savannah River National Laboratory. The version 1.0 and 3.0 database files contain 496 and 838 radionuclides, respectively, and though one would expect the newer version to include all the 496 radionuclides, 35 radionuclides are listed in version 1.0 that are not included in version 3.0. The majority of these has either extremely short or long half-lives or is no longer in production; however, some of the short-lived radionuclides might produce progeny of great interest at DOE sites. In addition, 122 radionuclides were found to have different half-lives in the two versions, with 21 over 3 percent different and 12 over 10 percent different.

  1. PSR J2022 plus 3842: An Energetic Radio and X-Ray Pulsar Associated with SNR G76.9 plus 1.0

    NASA Technical Reports Server (NTRS)

    Arzoumanian, Z.; Gotthelf, E. V.; Ransom, S. M.; Kothes, R.; Landecker, T. L.

    2010-01-01

    We present Chandra X-ray Observatory, Robert C. Byrd Green Bank Radio Telescope (GBT), and Rossi X-ray Timing Explorer (RXTE) observations directed toward the radio supernova remnant (SNR) G76.9+1.0. The Chandra investigation reveals a hard, unresolved X-ray source coincident with the midpoint of the double-lobed radio morphology and surrounded by faint, compact X-ray nebulosity. These features suggest that an energetic neutron star is powering a pulsar wind nebula (PWN) seen in synchrotron emission. Indeed, the spatial relationship of the X-ray and radio emissions is remarkably similar to the extended emission around the Vela pulsar. A follow-up pulsation search with the GBT uncovered a highly-dispersed (DM = 427 +/- 1 pc/cu cm) and highly-scattered pulsar with a period of 24 ms. Its subsequently measured spin-down rate implies a characteristic age T(sub c) = 8.9 kyr, making PSR J2022+3842 the most rapidly rotating young radio pulsar known. With a spin-down luminosity E = 1.2 x 10(exp 38) erg/s, it is the second-most energetic Galactic pulsar known, after the Crab pulsar. The 24-ms pulsations have also been detected in the RXTE observation; the combined Chandra and RXTE spectral fit suggests that the Chandra point-source emission is virtually 100% pulsed. The 2-16 keV spectrum of the narrow (0.06 cycles FWHM) pulse is well-fitted by an absorbed power-law model with column density N(sub H) = (1.7 +/- 0.5) x 10(exp 22)/sq cm and photon index Gamma = 1.0 +/- 0.2, strongly suggestive of magnetospheric emission. For an assumed distance of 10 kpc, the 2-10 keV luminosity of L(sub X) = 6.9 x 10(exp 33) erg/s suggests one of the lowest known X-ray conversion efficiencies L(sub X)/ E = 5.8 x 10(exp -5), similar to that of the Vela pulsar. Finally, the PWN around PSR J2022+3842 revealed by Chandra is also underluminous, with F(sub PWN)/ F(sub PSR) < or approx.1 in the 2-10 keV band, a further surprise given the pulsar's high spin-down luminosity.

  2. DNA-stacking interactions determine the sequence specificity of the deoxyribonuclease activity of 1,10-phenanthroline-copper ion.

    PubMed

    Schaeffer, F; Rimsky, S; Spassky, A

    1996-07-26

    Bis(1,10-phenanthroline)-copper(I) ion (OP2Cu+) binds reversibly to B-DNA and makes single-stranded cuts by oxidative attack on the deoxyribose moiety. The deoxyribonuclease activity is sequence-dependent yet not nucleotide-specific at the cutting site. OP2Cu+ sequence specificity was analysed in terms of local variations of DNA stability. Kinetic constants of strand cleavage were measured at sequence positions on the two strands and converted into activation free energies of the cleavage reaction. DNA unwinding free energies were calculated from the base sequence using B-DNA stacking parameters for calculations. The two free-energy variations were statistically compared for a series of DNA restriction fragments bearing the binding sites of regulatory proteins and representing a total of 345 DNA base positions. This study shows that the mean activation free energy of strand cleavage at a pair of opposing sugars across the DNA minor groove varies like the unwinding free energy of the DNA sequence delimited by opposing sugars (3 to 4 bp). A statistical equality between the two free-energy variations is demonstrated when considering the sum of the two cleavage events at the opposing sugars. Systematic deviations between the two free-energy distributions were observed at specific sequences, including polypurine-polypyrimidine tracts (AnTm/AmTn, CnTmCp/GpAmGn), alternating purine-pyrimidine tracts ((TA)n/(TA)n, (TG)n/(CA)n) and at certain G+C-rich triplets (GGC, GCC and CGC). The physical significance of these observations is discussed and a model of OP2Cu+ binding and cleavage specificity based on the free-energy equality is proposed.

  3. New XAFS spectroscopic investigations in the 1-2 keV region. Final report on LDRD program

    SciTech Connect

    Wong, J.; Froba, M.; Tamura, E.

    1996-03-01

    Until recently x-ray absorption fine structure (XAFS) measurements in the 1-2 keV region remained a challenging experimental task. This was primarily due to the lack of an adequate monochromator crystal that possessed both the required x-ray properties (large d-spacing, high resolution and reflectivity) and materials properties (ultra-high vacuum (UHV) capability, damage resistance in a synchrotron radiation beam, absence of constituent element absorption edges and stability, both thermal and mechanical). Traditionally, XAFS spectra in this photon energy range have been measured in a piece-wise fashion using a combination of monochromator crystals. Very recently, we have an experimental breakthrough in XAFS spectroscopy in this soft x-ray region. This energy region is of great importance for materials and basic research since the K-edges of Na (1070 eV), Mg (1303 eV), Al (1557 eV) and Si (1839 eV), the L-edges of some 4p elements from Ga to Sr and the M-edges of the rare-earth elements fall within this energy window of the electromagnetic spectrum. YB{sub 66}, a complex binary semiconducting yttrium boride having a cubic crystal structure with a lattice constant of 23.44 {angstrom} has been singled out as a candidate monochromator material for synchrotron radiation in the 1-2 keV region. There is no intrinsic absorption by the constituent elements in this region, which can adequately be dispersed by the (400) reflection having a 2d value of 11.76 {angstrom}. In terms of vacuum compatibility, resistance to radiation damage, thermal and mechanical stability, YB{sub 66} satisfies all the material requirements for use as a monochromator in a synchrotron beam. In the past few years, LLNL in collaboration with a number of other research institutes has pioneered the development of this unique man-made crystal for use as soft x-ray monochromator with synchrotron light sources for materials science studies. 23 refs., 4 figs.

  4. Spacesuit Portable Life Support System Breadboard (PLSS 1.0) Development and Test Results

    NASA Technical Reports Server (NTRS)

    Vogel, Matt R.; Watts, Carly

    2011-01-01

    A multi-year effort has been carried out at NASA-JSC to develop an advanced Extravehicular Activity (EVA) PLSS design intended to further the current state of the art by increasing operational flexibility, reducing consumables, and increasing robustness. Previous efforts have focused on modeling and analyzing the advanced PLSS architecture, as well as developing key enabling technologies. Like the current International Space Station (ISS) Extravehicular Mobility Unit (EMU) PLSS, the advanced PLSS comprises of three subsystems required to sustain the crew during EVA including the Thermal, Ventilation, and Oxygen Subsystems. This multi-year effort has culminated in the construction and operation of PLSS 1.0, a test rig that simulates full functionality of the advanced PLSS design. PLSS 1.0 integrates commercial off the shelf hardware with prototype technology development components, including the primary and secondary oxygen regulators, ventilation loop fan, Rapid Cycle Amine (RCA) swingbed, and Spacesuit Water Membrane Evaporator (SWME). Testing accumulated 239 hours over 45 days, while executing 172 test points. Specific PLSS 1.0 test objectives assessed during this testing include: confirming key individual components perform in a system level test as they have performed during component level testing; identifying unexpected system-level interactions; operating PLSS 1.0 in nominal steady-state EVA modes to baseline subsystem performance with respect to metabolic rate, ventilation loop pressure and flow rate, and environmental conditions; simulating nominal transient EVA operational scenarios; simulating contingency EVA operational scenarios; and further evaluating individual technology development components. Successful testing of the PLSS 1.0 provided a large database of test results that characterize system level and component performance. With the exception of several minor anomalies, the PLSS 1.0 test rig performed as expected; furthermore, many system responses trended in accordance with pre-test predictions.

  5. Statistical investigation of IMF Bz effects on energetic (0.1- to 16-keV) magnetospheric O+ ions

    NASA Astrophysics Data System (ADS)

    Lennartsson, O. W.

    1995-12-01

    More than 2 years of magnetospheric O+ data from the Plasma Composition Experiment on the ISEE 1 spacecraft are compared, in a statistical manner, with concurrent data on the interplanetary magnetic field (IMF) and the solar wind plasma in an attempt to clarify the geophysical responses to varying solar wind inputs, in particular to variations in the GSM Bz component of the IMF. It is found that the energy density of 0.1- to 16-keV O+ ions in the plasma sheet, inside of 23RE, is well correlated with the average solar wind energy flux during the preceding few hours, whether that flux is measured by its electromagnetic (Poynting) component P or by its far greater kinetic component K. Although P and K are well correlated with each other, the correlation of the O+ energy density is slightly better with K than with P during times of positive Bz, while the opposite holds for negative Bz. In either case the O+ energy density is more nearly proportional to K, and, given a typical value of K, there is at most a marginal (less than a factor of 2) increase in this density associated with a negative Bz. Except for this latter effect, which can perhaps be taken as evidence that a change in polarity of Bz from positive to negative may induce ``unloading'' of internal tail energy, there is no evidence in these O+ data, including data from the inner magnetosphere (L<10), that a negative, or southward, Bz is inherently favorable to the transfer of solar wind power across the magnetopause. These findings, together with the results of correlating the hourly AE index with P and K, suggest that the strong dependence of the AE on the Bz polarity is substantially exaggerated by the lack of AE magnetometers above 71° magnetic latitude.

  6. Acetato(1,10-phenanthroline-5,6-dione)silver(I) trihydrate

    PubMed Central

    Onuegbu, Jonathan; Butcher, Ray J.; Hosten, Charles; Udeochu, Uche Charles; Bakare, Oladapo

    2008-01-01

    In the structure of the title compound, [Ag(C2H3O2)(C12H6N2O2)]·3H2O, the AgI atom is coordinated by both 1,10-phenanthroline-5,6-dione N atoms and one O atom from the acetate anion. The three water mol­ecules are involved in extensive hydrogen bonding to each other and to the acetate O and 1,10-phenanthroline-5,6-dione O atoms. In addition, there are weak C—H⋯O inter­actions. PMID:21201351

  7. Spacesuit Portable Life Support System Breadboard (PLSS 1.0) Development and Test Results

    NASA Technical Reports Server (NTRS)

    Watts, Carly A.; Vogel, Matt

    2012-01-01

    A multi-year effort has been carried out at the Johnson Space Center to develop an advanced EVA PLSS design intended to further the current state of the art by increasing operational flexibility, reducing consumables, and increasing robustness. This multi-year effort has culminated in the construction and operation of PLSS 1.0, a test rig that simulates full functionality of the advanced PLSS design. PLSS 1.0 integrates commercial off-the-shelf hardware with prototype technology development components, including the primary and secondary oxygen regulators, ventilation loop fan, Rapid Cycle Amine (RCA) swingbed, and Spacesuit Water Membrane Evaporator (SWME). PLSS 1.0 was tested from June 17th through September 30th, 2011. Testing accumulated 233 hours over 45 days, while executing 119 test points. An additional 164 hours of operational time were accrued during the test series, bringing the total operational time for PLSS 1.0 testing to 397 hours. Specific PLSS 1.0 test objectives assessed during this testing include: (1) Confirming prototype components perform in a system level test as they have performed during component level testing, (2) Identifying unexpected system-level interactions (3) Operating PLSS 1.0 in nominal steady-state EVA modes to baseline subsystem performance with respect to metabolic rate, ventilation loop pressure and flow rate, and environmental conditions (4) Simulating nominal transient EVA operational scenarios (5) Simulating contingency EVA operational scenarios (6) Further evaluating prototype technology development components Successful testing of the PLSS 1.0 provided a large database of test results that characterize system level and component performance. With the exception of several minor anomalies, the PLSS 1.0 test rig performed as expected. Documented anomalies and observations include: (1) Ventilation loop fan controller issues at high fan speeds (near 70,000 rpm, whereas the fan speed during nominal operations would be closer to 35,000 rpm) (2) RCA performance at boundary conditions, including carbon dioxide and water vapor saturation events, as well as reduced vacuum quality (3) SWME valve anomalies (4 documented cases where the SWME failed to respond to a control signal or physically jammed, preventing SWME control) (4) Reduction of SWME hollow fiber hydrophobicity and significant reduction of the SWME degassing capability after significant accumulated test time.

  8. Naval Sea Systems Command Acquisition Strategy Guide v1.0

    DTIC Science & Technology

    2010-04-01

    Strategy Guide v1.0 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT...FINAL REPORT 20 NAVSEA Acquisition Strategy Guide v1.0 TABLE OF CONTENTS Page 3 Title Page LIST OF TABLES AND FIGURES Table 1...Final Report B-1 APPENDIX C - Acquisition Strategy Suggested Routing Sequence C-1 APPENDIX D – References D-1 APPENDIX E – Acronym List

  9. LITHO1.0: An Updated Crust and Lithosphere Model of the Earth (Postprint)

    DTIC Science & Technology

    2012-03-22

    AFRL-RV-PS- AFRL-RV-PS- TP-2012-0048 TP-2012-0048 LITHO1.0: AN UPDATED CRUST AND LITHOSPHERE MODEL OF THE EARTH (POSTPRINT...01 Sep 2010 to 21 Mar 2012 4. TITLE AND SUBTITLE LITHO1.0: AN UPDATED CRUST AND LITHOSPHERE MODEL OF THE EARTH (POSTPRINT) An 5a...sets of longer period phase data that help to constrain deep lithosphere properties. To model these data, a starting model for the crust at a nominal

  10. LITHO1.0: An Updated Crust and Lithosphere Model of the Earth

    DTIC Science & Technology

    2010-09-01

    REPRINT 3. DATES COVERED (From • To) TITLE AND SUBTITLE -llTHOLO: AN UPDATED CRUST AND LITHOSPHERE MODEL OF THE EARTH J 5a. CONTRACT NUMBER FA8718-09...developing LITHO1.0: an updated crust and lithosphere model of the Earth. The overall plan is to take the popular CRUST2.0 model—a global model of crustal... lithospheric structure. The new model. LITHO 1.0, will be constrained by many different datasets, including extremely large new datasets of relatively

  11. Measurement of the 20 and 90 keV Resonances in the {sup 18}O(p,{alpha}){sup 15}N Reaction via the Trojan Horse Method

    SciTech Connect

    La Cognata, M.; Spitaleri, C.; Cherubini, S.; Crucilla, V.; Gulino, M.; Lamia, L.; Pizzone, R. G.; Puglia, S. M. R.; Rapisarda, G. G.; Romano, S.; Sergi, M. L.; Tumino, A.; Mukhamedzhanov, A. M.; Tribble, R. E.; Banu, A.; Goldberg, V. Z.; Tabacaru, G.; Trache, L.; Irgaziev, B.; Coc, A.

    2008-10-10

    The {sup 18}O(p,{alpha}){sup 15}N reaction is of primary importance in several astrophysical scenarios, including fluorine nucleosynthesis inside asymptotic giant branch stars as well as oxygen and nitrogen isotopic ratios in meteorite grains. Thus the indirect measurement of the low energy region of the {sup 18}O(p,{alpha}){sup 15}N reaction has been performed to reduce the nuclear uncertainty on theoretical predictions. In particular the strength of the 20 and 90 keV resonances has been deduced and the change in the reaction rate evaluated.

  12. Position detection of 17-25 keV x-rays in krypton and xenon with a resolution of 18-50 m (FWHM)

    SciTech Connect

    Fischer, J.; Radeka, V.; Smith, G.C.

    1985-10-01

    Measurements have been made of x-ray position resolution in a proportional chamber with both Kr/10% CO2 and Xe/10% CO2, for the x-ray energy region 17 to 25 keV. Position resolutions in the range of 18 to 50 m (FWHM) are obtained in krypton, and in the range 50 to 100 m (FWHM) for xenon. These results are interpreted in terms of the physical limitation to resolution due to the range of photoelectrons and Auger electrons emitted from the x-ray absorbing atom.

  13. Energy.

    ERIC Educational Resources Information Center

    Shanebrook, J. Richard

    This document describes a course designed to acquaint students with the many societal and technological problems facing the United States and the world due to the increasing demand for energy. The course begins with a writing assignment that involves readings on the environmental philosophy of Native Americans and the Chernobyl catastrophe.…

  14. DNA binding of iron(II) mixed-ligand complexes containing 1,10-phenanthroline and 4,7-diphenyl-1,10-phenanthroline.

    PubMed

    Mudasir; Yoshioka, N; Inoue, H

    1999-01-01

    Absorption spectroscopy and circular dichroism (CD) have been used to characterize the DNA binding of [Fe(phen)3]2+, [Fe(phen)2(DIP)]2+ and [Fe(phen)(DIP)2]2+ where phen and DIP stand for 1,10-phenanthroline and 4,7-diphenyl-1,10-phenanthroline, respectively. Both [Fe(phen)3]2+ and [Fe(phen)2(DIP)]2+ bind weakly to calf thymus DNA (CT-DNA) in an electrostatic mode, while [Fe(phen)(DIP)2]2+ binds more strongly to CT-DNA, possibly in an intercalation mode. The hypochromicity, red shift and Kb increase in the order [Fe(phen)3]2+ < [Fe(phen)2(DIP)]2+ < [Fe(phen)(DIP)2]2+ in accordance with the increase in size and hydrophobicity of the iron(II) complexes. The thermodynamic parameters obtained suggest that the DNA binding of both [Fe(phen)3]2+ and [Fe(phen)2(DIP)]2+ is entropically driven, while that of [Fe(phen)(DIP)2]2+ is enthalpically driven. A strong CD spectrum in the UV and visible region develops upon addition of CT-DNA into the racemate solution of each iron(II) complex (Pfeiffer effect). This has revealed that a shift in diastereomeric inversion equilibrium takes place in the solution to yield an excess of one of the DNA-complex diastereomers. The striking resemblance of the CD spectral profiles to those of the pure delta-enantiomer indicates that the delta-enantiomer of the iron(II) complexes is preferentially bound to CT-DNA. The mechanism of the development of Pfeiffer CD is proposed on the basis of kinetic studies on the DNA binding of the racemic iron(II) complexes.

  15. SMM detection of diffuse Galactic 511 keV annihilation radiation

    NASA Technical Reports Server (NTRS)

    Share, G. H.; Kinzer, R. L.; Kurfess, J. D.; Messina, D. C.; Purcell, W. R.

    1988-01-01

    Observations of the 511 keV annihilation line from the vicinity of the Galactic center from October to February for 1980/1981, 1981/1982, 1982/1983, 1984/1985, and 1985/1986 are presented. The measurements were made with the gamma-ray spectrometer on the SMM. The design of the instrument and some of its properties used in the analysis are described, and the methods used for accumulating, fitting, and analyzing the data are outlined. It is shown how the Galactic 511 keV line was separated from the intense and variable background observed in orbit. The SMM observations are compared with previous measurements of annihilation radiation from the Galactic center region, and the astrophysical implications are discussed. It is argued that most of the measurements made to date suggest the presence of an extended Galactic source of annihilation radiation.

  16. Limits on a variable source of 511 keV annihilation radiation near the Galactic center

    NASA Technical Reports Server (NTRS)

    Share, Gerald H.; Leising, Mark D.; Messina, Daniel C.; Purcell, William R.

    1990-01-01

    The Gamma Ray Spectrometer (GRS) on the Solar Maximum Mission satellite (SMM) has observed a strong Galactic source of 511 keV annihilation radiation from its launch in 1980 to its reentry in 1989. These observations are consistent with an extended source having an intensity of about 0.002 gamma/sq cm/s averaged over the central radian of Galactic longitude. These data are searched for evidence of the variable Galactic center source of 511 keV line radiation which was reported to have reappeared in 1988 by Leventhal et al. The SMM data are consistent with, but do not require, a compact source emitting a time-averaged flux of about 0.0004 gamma/sq cm/s during about 3 month transits in 1987 and 1988; they are inconsistent with a compact source flux in excess of 0.0008 gamma/sq cm/s for each year.

  17. A new international geostationary electron model: IGE-2006, from 1 keV to 5.2 MeV

    NASA Astrophysics Data System (ADS)

    Sicard-Piet, A.; Bourdarie, S.; Boscher, D.; Friedel, R. H. W.; Thomsen, M.; Goka, T.; Matsumoto, H.; Koshiishi, H.

    2008-07-01

    Département Environnement Spatial, Office National d'Etudes et de Recherches Aérospatiales (ONERA) has been developing a model for the geostationary electron environment since 2003. Until now, this model was called Particle ONERA-LANL Environment (POLE), and it is valid from 30 keV up to 5.2 MeV. POLE is based on the full complement of Los Alamos National Laboratory geostationary satellites, covers the period 1976-2005, and takes into account the solar cycle variation. Over the period 1976 to present, four different detectors were flown: charged particle analyzer (CPA), synchronous orbit particle analyzer (SOPA), energetic spectra for particles (ESP), and magnetospheric plasma analyzer (MPA). Only the first three were used to develop the POLE model. Here we extend the energy coverage of the model to low energies using MPA measurements. We further include the data from the Japanese geostationary spacecraft, Data Relay Test Satellite (DRTS). These data are now combined into an extended geostationary electron model which we call IGE-2006.

  18. Single impacts of keV fullerene ions on free standing graphene: Emission of ions and electrons from confined volume

    SciTech Connect

    Verkhoturov, Stanislav V.; Geng, Sheng; Schweikert, Emile A.; Czerwinski, Bartlomiej; Young, Amanda E.; Delcorte, Arnaud

    2015-10-28

    We present the first data from individual C{sub 60} impacting one to four layer graphene at 25 and 50 keV. Negative secondary ions and electrons emitted in transmission were recorded separately from each impact. The yields for C{sub n}{sup −} clusters are above 10% for n ≤ 4, they oscillate with electron affinities and decrease exponentially with n. The result can be explained with the aid of MD simulation as a post-collision process where sufficient vibrational energy is accumulated around the rim of the impact hole for sputtering of carbon clusters. The ionization probability can be estimated by comparing experimental yields of C{sub n}{sup −} with those of C{sub n}{sup 0} from MD simulation, where it increases exponentially with n. The ionization probability can be approximated with ejecta from a thermally excited (3700 K) rim damped by cluster fragmentation and electron detachment. The experimental electron probability distributions are Poisson-like. On average, three electrons of thermal energies are emitted per impact. The thermal excitation model invoked for C{sub n}{sup −} emission can also explain the emission of electrons. The interaction of C{sub 60} with graphene is fundamentally different from impacts on 3D targets. A key characteristic is the high degree of ionization of the ejecta.

  19. 63Cu(n ,γ ) cross section measured via 25 keV activation and time of flight

    NASA Astrophysics Data System (ADS)

    Weigand, M.; Beinrucker, C.; Couture, A.; Fiebiger, S.; Fonseca, M.; Göbel, K.; Heftrich, M.; Heftrich, T.; Jandel, M.; Käppeler, F.; Krása, A.; Lederer, C.; Lee, H. Y.; Plag, R.; Plompen, A.; Reifarth, R.; Schmidt, S.; Sonnabend, K.; Ullmann, J. L.

    2017-01-01

    In the nuclear mass range A ≈60 to 90 of the solar abundance distribution the weak s -process component is the dominant contributor. In this scenario, which is related to massive stars, the overall neutron exposure is not sufficient for the s process to reach mass flow equilibrium. Hence, abundances and isotopic ratios are very sensitive to the neutron capture cross sections of single isotopes, and nucleosynthesis models need accurate experimental data. In this work we report on a new measurement of the 63Cu(n ,γ ) cross section for which the existing experimental data show large discrepancies. The 63Cu(n ,γ ) cross section at kBT =25 keV was determined via activation with a quasistellar neutron spectrum at the Joint Research Centre (JRC) in Geel, and the energy dependence was determined with the time-of-flight technique and the calorimetric 4 π BaF2 detector array DANCE at the Los Alamos National Laboratory. We provide new cross section data for the whole astrophysically relevant energy range.

  20. Investigation on gamma-ray position sensitivity at 662 keV in a spectroscopic 3' x 3' LaBr3:Ce scintillator

    NASA Astrophysics Data System (ADS)

    Giaz, A.; Camera, F.; Birocchi, F.; Blasi, N.; Boiano, C.; Brambilla, S.; Coelli, S.; Fiorini, C.; Marone, A.; Million, B.; Riboldi, S.; Wieland, O.

    2015-02-01

    The position sensitivity of a thick, cylindrical and continuous 3" x 3" (7.62 cm x 7.62 cm) LaBr3:Ce crystal was studied using a 1 mm collimated beam of 662 keV gamma rays from a 400 MBq intense 137Cs source and a spectroscopic photomultiplier (PMT) (HAMAMATSU R6233-100SEL). The PMT entrance window was covered by black absorber except for a small window 1 cm x 1 cm wide. A complete scan of the detector over a 0.5 cm step grid was performed for three positions of the 1 cm x 1 cm window. For each configuration the energy spectrum was measured and the peak centroid, the FWHM, the area and peak asymmetry of the 662 keV gamma transition were analyzed. The data show that, even in a 3" thick LaBr3:Ce crystal with diffusive surfaces the position of the full energy peak centroid depends on the source position. We verified that, on average, the position of the full energy peak centroids measured in the three 1 cm x 1 cm window configurations is sufficient for the correct identification of the collimated gamma source position.