Science.gov

Sample records for 1-2 mm diameter

  1. Development and study of a 3. 2-mm-diameter, 1. 2-m-long two-stage plasma-arc-driven railgun for hypervelocity hydrogen pellet injection

    SciTech Connect

    Zhang, D.; Kim, K.

    1988-12-01

    A detailed description of a prototype, fuseless, plasma-arc-driven, two-stage railgun system with a 1.2-m-long railgun barrel and a 3.2-mm-diameter circular bore is presented, along with the preliminary results indicating its capabilities and limitations. A hydrogen pellet generator, which has a straight-tube configuration and which is also operated as a gas gun, is employed as the first stage of the two-stage acceleration system. The design details of this preacceleration system and the results illustrating its performance are first presented. The second-stage accelerator which acts as a booster accelerator, is a fuseless plasma-arc-driven railgun, and constitutes the core of the entire two-stage acceleration scheme. Details of its design, ancillary systems, operation, and performance are described next in this report. The experimental data included herein represent only the preliminary data, and the system modifications that led to the improvements are described in the accompanying two other progress reports that precede this. 19 refs.

  2. Helical magneto-cumulative generator 280 mm in diameter

    NASA Astrophysics Data System (ADS)

    Demidov, V. A.; Kazakov, S. A.; Boriskin, A. S.; Vlasov, Yu. V.; Yanenko, V. A.; Nikolaev, N. I.; Volodchenkov, S. I.

    2015-01-01

    Several possibilities of preamplifier energy and power increasing are considered: using a more powerful (HMX-based) conical HE-charge in the central tube of the magneto-cumulative generator, using a magnetic flux finish pressing out device with axial initiation of the HE charge, and increasing the inner diameter of the helix. A magneto-cumulative generator (MCG) with a helix 280 mm in diameter (MCG-280) is developed. The new preamplifier has a power of ≈400 GW and is able to power a ten-element DMCG480 with an initial inductance of ≈0.2 µH by a current of ≈10 MA with a characteristic current rise time (by a factor of e at the final stage of its operation) τ e = 32 µs.

  3. Development of mini-tablets with 1mm and 2mm diameter.

    PubMed

    Tissen, Corinna; Woertz, Katharina; Breitkreutz, Joerg; Kleinebudde, Peter

    2011-09-15

    The feasibility of formulating mini-tablets with 1mm diameter on a rotary-die press in comparison to mini-tablets of 2mm was investigated. To gain insight into the production of 1mm mini-tablets, three model drugs of different compression characteristics were chosen, namely quinine hydrochloride, ibuprofen and spray-dried gentian extract. A high drug load in combination with robust and reproducible mechanical properties was requested. Depending on the individual drug substance, mini-tablets were produced by direct compression or after roll-compaction/dry granulation. The tensile strength, mass, and their variation coefficients were determined to assess the mechanical properties of the tablets. The content uniformity and the dissolution behavior of selected batches were analyzed. For the first time 1mm mini-tablets could be successfully produced by direct compression (90% quinine hydrochloride; 90% dried gentian extract) and after roll compaction (70% ibuprofen). Depending on the applied compression pressure, 1mm mini-tablets with quinine hydrochloride exhibited robust mechanical properties (e.g. median tensile strength of 2.02N/mm(2)) with equal or lower variance of distribution compared to the 2mm compacts. With respect to content uniformity of dosage forms, 1mm mini-tablets containing 80% quinine hydrochloride met the requirements of the European Pharmacopeia (AV=6.8). PMID:21726616

  4. 40 CFR Table Mm-1 to Subpart Mm of... - Default Factors for Petroleum Products and Natural Gas Liquids 1 2

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... and Natural Gas Liquids 1 2 MM Table MM-1 to Subpart MM of Part 98 Protection of Environment... Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl... Natural Gas Liquids Aviation Gasoline 0.1120 85.00 0.3490 Special Naphthas 0.1222 84.76 0.3798...

  5. 40 CFR Table Mm-1 to Subpart Mm of... - Default Factors for Petroleum Products and Natural Gas Liquids 1 2

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... and Natural Gas Liquids 1 2 MM Table MM-1 to Subpart MM of Part 98 Protection of Environment... Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl... Natural Gas Liquids Aviation Gasoline 0.1120 85.00 0.3490 Special Naphthas 0.1222 84.76 0.3798...

  6. 40 CFR Table Mm-1 to Subpart Mm of... - Default Factors for Petroleum Products and Natural Gas Liquids 1 2

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... and Natural Gas Liquids 1 2 MM Table MM-1 to Subpart MM of Part 98 Protection of Environment... Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl... Natural Gas Liquids Aviation Gasoline 0.1120 85.00 0.3490 Special Naphthas 0.1222 84.76 0.3798...

  7. 40 CFR Table Mm-1 to Subpart Mm of... - Default Factors for Petroleum Products and Natural Gas Liquids 1 2

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... and Natural Gas Liquids 1 2 MM Table MM-1 to Subpart MM of Part 98 Protection of Environment... Factors for Petroleum Products and Natural Gas Liquids 1 2 Products Column A: density(metric tons/bbl... Natural Gas Liquids Aviation Gasoline 0.1120 85.00 0.3490 Special Naphthas 0.1222 84.76 0.3798...

  8. Sporadic Creutzfeldt-Jakob Disease MM1+2C and MM1 are Identical in Transmission Properties.

    PubMed

    Kobayashi, Atsushi; Matsuura, Yuichi; Iwaki, Toru; Iwasaki, Yasushi; Yoshida, Mari; Takahashi, Hitoshi; Murayama, Shigeo; Takao, Masaki; Kato, Shinsuke; Yamada, Masahito; Mohri, Shirou; Kitamoto, Tetsuyuki

    2016-01-01

    The genotype (methionine, M or valine, V) at polymorphic codon 129 of the PRNP gene and the type (1 or 2) of abnormal prion protein in the brain are the major determinants of the clinicopathological features of sporadic Creutzfeldt-Jakob disease (CJD), thus providing molecular basis for classification of sporadic CJD, that is, MM1, MM2, MV1, MV2, VV1 or VV2. In addition to these "pure" cases, "mixed" cases presenting mixed neuropathological and biochemical features have also been recognized. The most frequently observed mixed form is the co-occurrence of MM1 and MM2, namely MM1+2. However, it has remained elusive whether MM1+2 could be a causative origin of dura mater graft-associated CJD (dCJD), one of the largest subgroups of iatrogenic CJD. To test this possibility, we performed transmission experiments of MM1+2 prions and a systematic neuropathological examination of dCJD patients in the present study. The transmission properties of the MM1+2 prions were identical to those of MM1 prions because MM2 prions lacked transmissibility. In addition, the neuropathological characteristics of MM2 were totally absent in dCJD patients examined. These results suggest that MM1+2 can be a causative origin of dCJD and causes neuropathological phenotype similar to that of MM1. PMID:25851836

  9. Ultra-Compact Multitip Scanning Probe Microscope with an Outer Diameter of 50 mm

    NASA Astrophysics Data System (ADS)

    Cherepanov, Vasily; Zubkov, Evgeny; Junker, Hubertus; Korte, Stefan; Blab, Marcus; Coenen, Peter; Voigtländer, Bert

    We present a multitip scanning tunneling microscope (STM) where four independent STM units are integrated on a diameter of 50 mm. The coarse positioning of the tips is done under the control of an optical microscope or an SEM in vacuum. The heart of this STM is a new type of piezoelectric coarse approach called Koala Drive which can have a diameter greater than 2.5 mm and a length smaller than 10 mm. Alternating movements of springs move a central tube which holds the STM tip or AFM sensor. This new operating principle provides a smooth travel sequence and avoids shaking which is intrinsically present for nanopositioners based on inertial motion with saw tooth driving signals. Inserting the Koala Drive in a piezo tube for xyz-scanning integrates a complete STM inside a 4 mm outer diameter piezo tube of <10 mm length. The use of the Koala Drive makes the scanning probe microscopy design ultra-compact and accordingly leads to a high mechanical stability. The drive is UHV, low temperature, and magnetic field compatible. The compactness of the Koala Drive allows building a four-tip STM as small as a single-tip STM with a drift of <0.2 nm/min and lowest resonance frequencies of 2.5 (xy) and 5.5 kHz (z). We present examples of the performance of the multitip STM designed using the Koala Drive.

  10. Use of 5-mm-diameter implants: Periotest values related to a clinical and radiographic evaluation.

    PubMed

    Aparicio, C; Orozco, P

    1998-12-01

    A modified design of the original Brånemark implant consisting of a cp. Titanium 5.0-mm-diameter self-tapping implant threaded up to the marginal platform has been proposed for specific indications. From February 1992 to November 1995, a total of 185 machined screw implants (Nobel Biocare, Gothenburg, Sweden) were installed in 45 patients to withstand 58 prostheses. Of these, 91 were 3.75-mm diameter and 94 were 5.0-mm wide. Most of the implants were placed in type B and C bone quantity and type 2 and 3 bone quality. A retrospective evaluation with regard to indications, marginal bone remodelling, Periotest values (PTv) and survival rate is presented. PTv and radiographic measurements were made at abutment connection and repeated 3, 6 and 12 months later and thereafter every year. The follow-up ranged from 16 to 55 months (mean 32.9 months) post-loading. Three patients with 8 5.0-mm implants dropped-out of the study at different stages. Out of the wide implants, 1 was expelled during the healing period; 3 were found mobile at the abutment connection; 1 lost its osseointegration suddenly after 2 years of function; 4 belonging to 1 patient did not meet the success criteria due to continuous marginal bone loss. The cumulative success rate of 5.0-mm implants (CSR) after 1 year of function was 97.2% for upper jaws and 88.4% in mandibles, whereas the CSR in maxilla after 48 months was 97.2% and 83.4% in mandibles. The obtained PTv from 5.0-mm-wide fixtures in maxilla and mandibles were respectively 1.1 and 0.6 units lower than those obtained PTv for 3.75-mm-diameter implants in the same patients. The hypothesis that there are differences in the damping capacity of the bone surrounding a 5.0-mm-wide implant compared to the 3.75-mm-diameter implant is supported by the PTv results. PMID:11429941

  11. Ionization Measurements of SuperCDMS SNOLAB 100 mm Diameter Germanium Crystals

    SciTech Connect

    Chagani, H.; Bauer, D.A.; Brandt, D.; Brink, P.L.; Cabrera, B.; Cherry, M.; Silva, E.Do Couto e; Godfrey, G.G.; Hall, J.; Hansen, S.; Hasi, J.; Kelsey, M.; Kenney, C.J.; Mandic, V.; Nagasawa, D.; Novak, L.; Mirabolfathi, N.; Partridge, R.; Radpour, R.; Resch, R.; Sadoulet, B.; /UC, Berkeley /Stanford U. /SLAC /Stanford U. /Santa Clara U. /Minnesota U.

    2012-06-12

    Scaling cryogenic Germanium-based dark matter detectors to probe smaller WIMP-nucleon cross-sections poses significant challenges in the forms of increased labor, cold hardware, warm electronics and heat load. The development of larger crystals alleviates these issues. The results of ionization tests with two 100 mm diameter, 33 mm thick cylindrical detector-grade Germanium crystals are presented here. Through these results the potential of using such crystals in the Super Cryogenic Dark Matter Search (SuperCDMS) SNOLAB experiment is demonstrated.

  12. A 2.5-mm diameter probe for photoacoustic and ultrasonic endoscopy.

    PubMed

    Yang, Joon-Mo; Chen, Ruimin; Favazza, Christopher; Yao, Junjie; Li, Chiye; Hu, Zhilin; Zhou, Qifa; Shung, K Kirk; Wang, Lihong V

    2012-10-01

    We have created a 2.5-mm outer diameter integrated photo-acoustic and ultrasonic mini-probe which can be inserted into a standard video endoscope's instrument channel. A small-diameter focused ultrasonic transducer made of PMN-PT provides adequate signal sensitivity, and enables miniaturization of the probe. Additionally, this new endoscopic probe utilizes the same scanning mirror and micromotor-based built-in actuator described in our previous reports; however, the length of the rigid distal section of the new probe has been further reduced to ~35 mm. This paper describes the technical details of the mini-probe and presents experimental results that both quantify the imaging performance and demonstrate its in vivo imaging capability, which suggests that it could work as a mini-probe for certain clinical applications. PMID:23188360

  13. [Extracorporeal shockwave lithotripsy in the treatment of distal ureteral stones larger than 10 mm in diameter].

    PubMed

    Ishii, Nobuyuki; Yoshinaga, Atsushi; Ohno, Rena; Chiba, Koji; Hayashi, Tetsuo; Kamata, Shigeyoshi; Watanabe, Toru; Yamada, Takumi

    2004-06-01

    Optimal treatment for distal ureteral stones remains controversial. During a period of 10 years, from December 1992 to December 2002, 103 distal ureteral stones larger than 10 mm in diameter were treated at our institution with extracorporeal shock wave lithotripsy (ESWL) using the Siemens Lithostar. Only 2 patients had a ureteral stent in place at the time of treatment. The overall stone-free rate was 98% with 1-12 session and 3-month stone-free rate was 95.1%. These data reveal that a high success rate was achieved in multisession ESWL. Therefore, ESWL is considered to be acceptable as first-line therapy for fragmentation of distal ureteral stones larger than 10 mm in diameter. PMID:15293734

  14. Characterization of the 80-mm diameter Hamamatsu PMTs for the KM3NeT project

    SciTech Connect

    Aiello, S.; Giordano, V.; Leonora, E.; Classen, L.; Reubelt, J.; Peek, H.; Visser, E.; Samtleben, D.; Kalekin, Oleg Collaboration: KM3NeT Collaboration

    2014-11-18

    The optical module designed for the KM3NeT project consists of 31 photomultipliers of 3-inch diameter housed into a 17-inch diameter glass sphere. A proposed photomultiplier was the R12199-02 Hamamatsu 80-mm diameter. 203 of such PMTs have been delivered from Hamamatsu and tested by the KM3NeT groups of NIKHEF-Amsterdam, ECAP-Erlangen and INFN-Catania. Tests have been performed to measure the main parameters, such as gain, transit time spread, dark pulses rate, fraction of spurious pulses, quantum efficiency and effective photocathode size. The main results matched with the requirements of the project. Methods and results are presented in this report.

  15. 200-mm-diameter neutral beam source based on inductively coupled plasma etcher and silicon etching

    SciTech Connect

    Kubota, Tomohiro; Nukaga, Osamu; Ueki, Shinji; Sugiyama, Masakazu; Inamoto, Yoshimasa; Ohtake, Hiroto; Samukawa, Seiji

    2010-09-15

    The authors developed a neutral beam source consisting of a 200-mm-diameter inductively coupled plasma etcher and a graphite neutralization aperture plate based on the design of a neutral beam source that Samukawa et al. [Jpn. J. Appl. Phys., Part 2 40, L779 (2001)] developed. They measured flux and energy of neutral particles, ions, and photons using a silicon wafer with a thermocouple and a Faraday cup and calculated the neutralization efficiency. An Ar neutral beam flux of more than 1 mA/cm{sup 2} in equivalent current density and a neutralization efficiency of more than 99% were obtained. The spatial uniformity of the neutral beam flux was within {+-}6% within a 100 mm diameter. Silicon etching using a F{sub 2}-based neutral beam was done at an etch rate of about 47 nm/min, while Cl{sub 2}-based neutral beam realized completely no undercut. The uniformity of etch rate was less than {+-}5% within the area. The etch rate increased by applying bias power to the neutralization aperture plate, which shows that accelerated neutral beam was successfully obtained. These results indicate that the neutral beam source is scalable, making it possible to obtain a large-diameter and uniform neutral beam, which is inevitable for application to mass production.

  16. An 8-mm diameter fibre robot positioner for massive spectroscopy surveys

    NASA Astrophysics Data System (ADS)

    Fahim, N.; Prada, F.; Kneib, J. P.; Glez-de-Rivera, G.; Hörler, P.; Sánchez, J.; Azzaro, M.; Becerril, S.; Bleuler, H.; Bouri, M.; Castaño, J.; Garrido, J.; Gillet, D.; Gómez, C.; Gómez, M. A.; González-Arroyo, A.; Jenni, L.; Makarem, L.; Yepes, G.; Arrillaga, X.; Carrera, M. A.; Diego, R.; Charif, M.; Hug, M.; Lachat, C.

    2015-06-01

    Massive spectroscopic survey are becoming trendy in astrophysics and cosmology, as they can address new fundamental knowledge such as understanding the formation of the Milky Way and probing the nature of the mysterious dark energy. To enable massive spectroscopic surveys, new technology has been developed to place thousands of optical fibres at a given position on a focal plane. This technology needs to be: (1) accurate, with micrometer positional accuracy; (2) fast to minimize overhead; (3) robust to minimize failure; and (4) low cost. In this paper, we present the development, properties, and performance of a new single 8-mm in diameter fibre positioner robot, using two 4-mm DC-brushless gearmotors, that allows us to achieve accuracies up to 0.07 arcsec (5 μm). This device has been developed in the context of the Dark Energy Spectroscopic Instrument.1

  17. Construction and manufacturing of a microgearhead with 1.9-mm outer diameter for universal application

    NASA Astrophysics Data System (ADS)

    Thuerigen, Christian; Beckord, Ulrich; Bessey, Reiner

    1999-03-01

    Many new applications in medicine, telecommunication, automation systems etc. require powerful microdrives. Speeds up to 100.000 rpm and output torques in the (mu) Nm-range are typical characteristics of electromagnetic micromotors with diameters of a few millimeters. To accomplish a powerful microdrive, these micromotors have to be combined with micro gearheads of the same outer diameter. For such a micro gearhead with toothed wheels manufactured by use of the LIGA process a multi-stage planetary gear has many advantages. Many stages with different gear ratios can be combined to achieve a great number of different transmission, but manufacturing tolerances and a clearance for assembly must be respected. Therefore besides the selection of a reliable gearhead type and a suitable manufacturing process the optimization of the tooth profile is the key to the implementation of powerful micro gear systems with high output torques and efficiencies. The involute profile is the most suitable toothing, but many calculations and simulations are required to find the right modulus, total depth of teeth, profile offset etc. In a joint project Dr. Fritz Faulhaber GmbH and Co. KG and the Institut fuer Mikrotechnik Mainz GmbH developed a powerful microdevice with an outer diameter of only 1.9 mm.

  18. Development of crystal supporting system for diameter of 400 mm silicon crystal growth

    NASA Astrophysics Data System (ADS)

    Iida, T.; Machida, N.; Takase, N.; Takano, K.; Matsubara, J.; Shiraishi, Y.; Kuramoto, M.; Yamagishi, H.

    2001-07-01

    The purpose of this project is the development of a crystal supporting system (CSS) for silicon crystals with large diameters of 400 mm. Amongst the many technical problems the one that the Super Silicon Crystal Research Institute Corp. (SSi) has directed its energies is to support a weight in excess of the ability of the Dash neck to support this weight. After considering various solutions, we developed a CSS that mechanically supports the silicon subsidiary cone formed between the Dash neck and crystal shoulder. Using this method, an approximately 400 kg ingot was successfully grown from 500 kg of molten silicon in a 36-in. quartz crucible. We confirmed that the CSS mechanism worked correctly through the entire crystal growth process. This paper presents some of the anticipated problems in the mechanical supporting method and the corresponding solutions. Finally, results from real crystal growth to test and verify machine operation are reported.

  19. Efficacy of silodosin in the treatment of distal ureteral stones 4 to 10 mm in diameter

    PubMed Central

    Yuksel, Mustafa; Yilmaz, Serdar; Tokgoz, Husnu; Yalcinkaya, Soner; Baş, Serkan; Ipekci, Tümay; Yildiz, Ali; Ates, Nihat; Savas, Murat

    2015-01-01

    Purpose: Few studies have investigated the efficacy of silodosin, a recently introduced selective alpha 1-A adrenoceptor antagonist, in medical expulsive therapy (MET) for ureteral calculi. The results of these studies, which all evaluated the efficacy of 8 mg/day, indicate that silodosin is a potential treatment for ureteral calculi. This study investigated the efficacy of 4 mg/day of silodosin for MET of distal ureteral stones 4 to 10 mm in diameter. Material and Method: After 70 patients had been randomized into 2 groups of 35 patients each, both the control and experimental groups (groups 1 and 2, respectively) were advised to take 75 mg/day of diclofenacsodiumas needed for pain relief but only the experimental group to take 4 mg/day of silodosin. After 21 days, the groups were compared regarding the stone expulsion rate and duration, number of renalcolicepisodes, and analgesicdosage. Results: The median expulsion rates were 71.4% and 91.4% in groups 1 and 2, respectively, and the difference between them was significant (P=0.031). The median expulsion durations were 12.91±6.14 and 8.03±4.99 days, respectively, and the difference between them was significant (P<0.001). No significant differences were found regarding the median number of renal colic episodes or median analgesic dosage. While no patients in group 1 experienced side effects, 5 patients (14%) in group 2 experienced retrograde ejaculation. Conclusion: These results indicate that 4 mg/day of silodos in facilitates the expulsion of distal ureteral stones 4 to 10 mm in diameter but does not significantly reduce the number of renal colic episodes or analgesic dosage. PMID:26770537

  20. Integrated intravascular ultrasound and optical-resolution photoacoustic microscopy with a 1-mm-diameter catheter

    NASA Astrophysics Data System (ADS)

    Bai, Xiaosong; Gong, Xiaojing; Lin, Riqiang; Hau, William; Song, Liang

    2014-03-01

    Intravascular ultrasound (IVUS) plays a vital role in assessing the severity of atherosclerosis and has greatly enriched our knowledge on atherosclerotic plaques. However, it mainly reveals the structural information of plaques. In contrast, spectroscopic and molecular photoacoustic imaging can potentially improve plaque composition identification, inflammation detection, and ultimately the stratification of plaque vulnerability and risk. In this work, we developed an integrated intravascular ultrasound and optical-resolution photoacoustic microscopy (IVUS-PAM) system with a single catheter as small as 1 mm in diameter, comparable to that of existing clinical IVUS catheters. In addition, by using a GRIN lens to focus the excitation laser pulse, the system provides an optical-diffraction limited photoacoustic lateral resolution as fine as 19.6 micrometers, ~10-fold finer than that of conventional intravascular photoacoustic imaging and existing IVUS technology. The system employs a custom-made miniaturized single-element ultrasonic transducer with a dimension of ~0.5 mm, a centre frequency of ~40 MHz, and a fractional bandwidth of ~60%. The IVUS-PAM can simultaneously acquire co-registered IVUS images with an axial resolution of ~40 micrometers and a lateral resolution of ~200 micrometers. In the future, IVUS-PAM may open up new opportunities for improved high-resolution vulnerable plaque imaging and image-guided stent deployment.

  1. Manufacturing of 100mm diameter GaSb substrates for advanced space based applications

    NASA Astrophysics Data System (ADS)

    Allen, L. P.; Flint, J. P.; Meshew, G.; Trevethan, J.; Dallas, G.; Khoshakhlagh, A.; Hill, C. J.

    2012-01-01

    Engineered substrates such as large diameter (100mm) GaSb wafers need to be ready years in advance of any major shift in DoD and commercial technology, and typically before much of the rest of the materials and equipment for fabricating next generation devices. Antimony based III-V semiconductors are of significant interest for advanced applications in optoelectronics, high speed transistors, microwave devices, and photovoltaics. GaSb demand is increasing due to its lattice parameter matching of various ternary and quaternary III-V compounds, as their bandgaps can be engineered to cover a wide spectral range. For these stealth and spaced based applications, larger format IRFPAs benefit clearly from next generation starting substrates. In this study, we have manufactured and tested 100mm GaSb substrates. This paper describes the characterization process that provides the best possible GaSb material for advanced IRFPA and SLS epi growth. The analysis of substrate by AFM surface roughness, particles, haze, GaSb oxide character and desorption using XPS, flatness measurements, and SLS based epitaxy quality are shown. By implementing subtle changes in our substrate processing, we show that a Sb-oxide rich surface is routinely provided for rapid desorption. Post-MBE CBIRD structures on the 100mm ULD GaSb were examined and reveals a high intensity, 6.6nm periodicity, low (15.48 arcsec) FWHM peak distribution that suggests low surface strain and excellent lattice matching. The Ra for GaSb is a consistent ~0.2-4nm, with average batch wafer warp of ~4 μm to provide a clean, flat GaSb template critical for next generation epi growth.

  2. A DEEP 1.2 mm MAP OF THE LOCKMAN HOLE NORTH FIELD

    SciTech Connect

    Lindner, R. R.; Baker, A. J.; Omont, A.; Fiolet, N. E-mail: ajbaker@physics.rutgers.edu E-mail: fiolet@iap.fr

    2011-08-20

    We present deep 1.2 mm continuum mapping of a 566 arcmin{sup 2} area within the Lockman Hole North (LHN) field, previously a target of the Spitzer Wide-Area Infrared Extragalactic survey and extremely deep 20 cm mapping with the Very Large Array, which we have obtained using the Max-Planck millimeter bolometer (MAMBO) array on the IRAM 30 m telescope. After filtering, our full map has an rms sensitivity ranging from 0.45 to 1.5 mJy beam{sup -1}, with an average of 0.75 mJy beam{sup -1}. Using the pixel flux distribution (PFD) in a map made from our best data, we determine the shape, normalization, and approximate flux density cutoff for 1.2 mm number counts well below our nominal sensitivity and confusion limits. After validating our full data set through comparison with this map, we successfully detect 41 1.2 mm sources with signal-to-noise ratio (S/N) > 4.0 and S{sub 1.2{sub mm}} {approx_equal} 2-5 mJy. We use the most significant of these detections to directly determine the integral number counts down to 1.8 mJy, which are consistent with the results of the PFD analysis. Ninety-three percent of our 41 individual detections have 20 cm counterparts, 49% have Spitzer/MIPS 24 {mu}m counterparts, and one may have a significant Chandra X-ray counterpart. We resolve {approx_equal} 3% of the cosmic infrared background (CIB) at 1.2 mm into significant detections and directly estimate a 0.05 mJy faint-end cutoff for the counts that is consistent with the full intensity of the 1.2 mm CIB. The median redshift of our 17 detections with spectroscopic or robust photometric redshifts is z{sub median} = 2.3, and rises to z{sub median} = 2.9 when we include redshifts estimated from the radio/far-infrared spectral index. By using a nearest neighbor and angular correlation function analysis, we find evidence that our S/N > 4.0 detections are clustered at the 95% confidence level.

  3. A simple multi-seeding approach to growth of large YBCO bulk with a diameter above 53 mm

    NASA Astrophysics Data System (ADS)

    Tang, Tian-wei; Wu, Dong-jie; Wu, Xing-da; Xu, Ke-Xi

    2015-12-01

    A successful simple multi-seeding approach to growing large size Y-Ba-C-O (YBCO) bulks is reported. Compared with the common single seeding method, our multi-seeding method is more efficient. By using four SmBa2Cu3O7-δ (Sm-123) seeds cut from a large size Sm-Ba-C-O (SmBCO) single domain, large YBCO samples up to 53 mm in diameter could be produced successfully and 100 mm diameter samples can also be grown. Experimental results show that the processing time can be shortened greatly by using this new approach, and the superconducting properties can also be improved. The Hall probe mapping shows that the trapped field distribution of 53 mm diameter multi-seeded sample is homogeneous and the peak value is up to 0.53 T. The magnetic levitation force density reaches to 14.7 N/cm2 (77 K, 0.5 T).

  4. The Canada-France High-z Quasar Survey: 1.2 mm observations

    NASA Astrophysics Data System (ADS)

    Omont, A.; Willott, C. J.; Beelen, A.; Bergeron, J.; Orellana, G.; Delorme, P.

    2013-04-01

    We report 250 GHz (1.2 mm) observations of a sample of 20 quasars at redshifts 5.8 < z < 6.5 from the Canada-France High-z Quasar Survey (CFHQS), using the Max-Planck-Millimeter-Bolometer (MAMBO) array at the 30-metre telescope of the Institut de Radioastronomie Millmétrique (IRAM). An rms sensitivity of ≲0.6 mJy was achieved for 65% of the sample, and of ≲1.0 mJy for 90%. Only one quasar, CFHQS J142952+544717, was robustly detected with S250 GHz = 3.46 ± 0.52 mJy. This indicates that one of the most powerful known starbursts at z ~ 6 is associated with this radio-loud quasar. On average, the other CFHQS quasars, which have a mean optical magnitude fainter than the previously studied samples of z ~ 6 quasars of the Sloan Digital Sky Survey (SDSS), have a mean 1.2 mm flux density ⟨ S250 GHz ⟩ = 0.41 ± 0.14 mJy; this average detection with a signal-to-noise (S/N) ratio of 2.9 is hardly meaningful. It would correspond to ⟨ LFIR ⟩ ≈ 0.94 ± 0.32 × 1012 L⊙, and an average star formation rate of a few 100 M⊙/yr, depending on the stellar initial mass function (IMF) and a possible contribution of an active galactic nucleus (AGN) to ⟨ LFIR ⟩. This is consistent with previous findings of Wang et al. on the far-infrared emission of z ~ 6 quasars and extends their results toward optically fainter sources.

  5. Three-degree-of-freedom ultrasonic motor using a 5-mm-diameter piezoelectric ceramic tube.

    PubMed

    Mingsen Guo; Junhui Hu; Hua Zhu; Chunsheng Zhao; Shuxiang Dong

    2013-07-01

    A small three-degree-of-freedom ultrasonic motor has been developed using a simple piezoelectric lead zirconate titanate (PZT)-tube stator (OD 5 mm, ID 3 mm, length 15 mm). The stator drives a ball-rotor into rotational motion around one of three orthogonal (x-, y-, and z-) axes by combing the first longitudinal and second bending vibration modes. A motor prototype was fabricated and characterized; its performance was superior to those of previous motors made with a PZT ceramic/metal composite stator of comparable size. The method for further improving the performance was discussed. The motor can be further miniaturized and it has potential to be applied to medical microrobots, endoscopes or micro laparoscopic devices, and cell manipulation devices. PMID:25004511

  6. Condensation heat transfer characteristics of R410A-oil mixture in 5 mm and 4 mm outside diameter horizontal microfin tubes

    SciTech Connect

    Huang, Xiangchao; Ding, Guoliang; Hu, Haitao; Zhu, Yu.; Gao, Yifeng; Deng, Bin

    2010-10-15

    Condensation heat transfer characteristics of R410A-oil mixture in 5 mm and 4 mm outside diameter horizontal microfin tubes were investigated experimentally. The experimental condensing temperature is 40 C, and nominal oil concentration range is from 0% to 5%. The test results indicate that the presence of oil deteriorates the heat transfer. The deterioration effect is negligible at nominal oil concentration of 1%, and becomes obvious with the increase of nominal oil concentration. At 5% nominal oil concentration, the heat transfer coefficient of R410A-oil mixture is found to have a maximum reduction of 25.1% and 23.8% for 5 mm and 4 mm tubes, respectively. The predictabilities of the existing condensation heat transfer correlations were verified with the experimental data, and Yu and Koyama correlation shows the best predictability. By replacing the pure refrigerant properties with the mixture's properties, Yu and Koyama correlation has a deviation of -15% to + 20% in predicting the local condensation heat transfer coefficient of R410A-oil mixture. (author)

  7. Design and performance of a parachute recovery system to recover 155-mm- and 8-inch-diameter artillery shells

    SciTech Connect

    Waye, D.E.; Peterson, C.W.; Botner, W.T.

    1986-01-01

    A parachute recovery system has been developed and demonstrated for the recovery of 155-mm- and 8-inch-diameter artillery shells. The recovery system functions after being subjected to gun launch accelerations of up to 18,000 g's axially and up to 400,000 rad/sec/sup 2/ radially. The parachute is deployed while the shell is still spinning at about 250 revolutions per second. To deploy the parachute while the shell is spinning, a double-swivel system was developed. The deployment signal for the recovery system is provided by an electronic timer. Over 250 tests have been performed on both the 155-mm- and 8-inch-diameter artillery shell. Impact velocities are between 100 and 120 feet per second. The latest version of the recovery systems has been proven to be over 95% successful for the recovery of 8-inch-diameter artillery shells and over 85% successful for the recovery of 155-mm-diameter artillery shells.

  8. Design and evaluation of coils for a 50 mm diameter induction coilgun launcher

    NASA Astrophysics Data System (ADS)

    Kaye, R. J.; Shokair, I. R.; Wavrik, R. W.; Dempsey, J. F.; Honey, W. E.; Shimp, K. J.; Douglas, G. M.

    Coilguns have the ability to provide magnetic pressure to projectiles which results in near constant acceleration. However, to achieve this performance and control projectile hearing, significant constraints are placed on the design of the coils. We are developing coils to produce an effective projectile base pressure of 100 MPa as a step toward reaching base pressures of 200 MPa. The design uses a scalable technology applicable to the entire range of breech to muzzle coils of a multi-stage launcher. This paper presents the design of capacitor-driven coils for launching nominal 50 mm, 350 gram projectiles. Design criteria, constraints, mechanical stress analysis, launcher performance, and test results are discussed.

  9. Operating the LCLS Gas Attenuator and Gas Detector System with Apertures of 6mm Diameter

    SciTech Connect

    Ryutov, D.D.; Bionta, R.M.; Hau-Riege, S.P.; Kishiyama, K.I.; Roeben, M.D.; Shen, S.; Stefan, P.M.; /SLAC

    2010-11-17

    The possibility of increasing the apertures of the LCLS gas attenuator/gas detector system is considered. It is shown that increase of the apertures from 3 to 6 mm, together with 4-fold reduction of the operation pressure does not adversely affect the vacuum conditions upstream or downstream. No change of the pump speed and the lengths of the differential pumping cells is required. One minor modification is the use of 1.5 cm long tubular apertures in the end cells of the differential pumping system. Reduction of the pressure does not affect performance of the gas attenuator/gas detector system at the FEL energies below, roughly, 2 keV. Some minor performance degradation occurs at higher energies.

  10. Design and evaluation of coils for a 50 mm diameter induction coilgun launcher

    SciTech Connect

    Kaye, R.J.; Shokair, I.R.; Wavrik, R.W.; Dempsey, J.F.; Honey, W.E.; Shimp, K.J.; Douglas, G.M.

    1993-12-31

    Coilguns have the ability to provide magnetic pressure to projectiles which results in near constant acceleration. However, to achieve this performance and control projectile hearing, significant constraints are placed on the design of the coils. We are developing coils to produce an effective projectile base pressure of 100 MPa (1kbar) as a step toward reaching base pressures of 200 MPa. The design uses a scalable technology applicable to the entire range of breech to muzzle coils of a multi-stage launcher. This paper presents the design of capacitor-driven coils for launching nominal 50 mm, 350 gram projectiles. Design criteria, constraints, mechanical stress analysis, launcher performance, and test results are discussed.

  11. Configuration of a 30-mm-diameter 94 kHz Ultrasonic Longitudinal Vibration System for Plastic Welding

    NASA Astrophysics Data System (ADS)

    Hongoh, Misugi; Yoshikuni, Masafumi; Miura, Hiroyuki; Miyamoto, Rei; Ueoka, Tetsugi; Tsujino, Jiromaru

    2004-05-01

    Vibration and welding characteristics of a 94 kHz ultrasonic plastic welding system are studied. The 94 kHz ultrasonic plastic welding systems consist of a 30-mm-diameter bolt-clamped Langevin-type PZT longitudinal transducers with four PZT rings, a stepped horn (vibration transform ratio N = 3.0) with a supporting flange at a nodal position and a catenoidal horn (N = 3.13) with an 8-mm-diameter welding tip. Maximum vibration velocity of the 94 kHz welding tip was 3.2 m/s (peak-to-zero value) at loaded condition. The welding characteristics of the 1.0-mm-thick polypropylene sheet specimens using the 94 kHz welding system were studied. Using the 94 kHz system, a weld strength of more than 370 N per one welded area was obtained at a vibration velocity of 2.7 m/sp-0 (peak-to-zero value), welding time of 0.8 s and static pressure of 600 kPa.

  12. Characterization of 100 mm diameter 4H-silicon carbide crystals with extremely low basal plane dislocation density

    SciTech Connect

    Dudley, M.; Zhang, N; Zhang, Y; Raghothamachar, B; Byrappa, S; Choi, G; Sanchez, E; Hansen, D; Drachev, R; Loboda, M

    2010-01-01

    Synchrotron White Beam X-ray Topography (SWBXT) studies are presented of basal plane dislocation (BPD) configurations and behavior in a new generation of 100mm diameter, 4H-SiC wafers with extremely low BPD densities (3-4 x 10{sup 2} cm{sup -2}). The conversion of non-screw oriented, glissile BPDs into sessile threading edge dislocations (TEDs) is observed to provide pinning points for the operation of single ended Frank-Read sources. In some regions, once converted TEDs are observed to re-convert back into BPDs in a repetitive process which provides multiple BPD pinning points.

  13. Characterization of 100 mm Diameter 4H-Silicon Carbide CrystalsWith Extremely Low Basal Plane Dislocation Density

    SciTech Connect

    M Dudley; N Zhang; Y Zhang; B Raghothamachar; S Byrappa; G Choi; E Drachev; M Loboda

    2011-12-31

    Synchrotron White Beam X-ray Topography (SWBXT) studies are presented of basal plane dislocation (BPD) configurations and behavior in a new generation of 100mm diameter, 4H-SiC wafers with extremely low BPD densities (3-4 x 10{sup 2} cm{sup -2}). The conversion of non-screw oriented, glissile BPDs into sessile threading edge dislocations (TEDs) is observed to provide pinning points for the operation of single ended Frank-Read sources. In some regions, once converted TEDs are observed to re-convert back into BPDs in a repetitive process which provides multiple BPD pinning points.

  14. Synchronous scan-projection lithography on overall circumference of fine pipes with a diameter of 2 mm

    NASA Astrophysics Data System (ADS)

    Horiuchi, Toshiyuki; Furuhata, Takahiro; Muro, Hideyuki

    2016-06-01

    The scan-projection exposure of small-diameter pipe surfaces was investigated using a newly developed prototype exposure system. It is necessary to secure a very large depth of focus for printing thick resist patterns on round pipe surfaces with a roughness larger than that of semiconductor wafers. For this reason, a camera lens with a low numerical aperture of 0.089 was used as a projection lens, and the momentary exposure area was limited by a narrow slit with a width of 800 µm. Thus, patterns on a flat reticle were replicated on a pipe surface by linearly moving the reticle and rotating the pipe synchronously. By using a reticle with inclined line-and-space patterns, helical patterns with a width of 30 µm were successfully replicated on stainless-steel pipes with an outer diameter of 2 mm and coated with a 10-µm-thick negative resist. The patterns replicated at the start and stop edges were smoothly stitched seamlessly.

  15. Operating characteristics of a 7. 6 mm (0. 30 inch) diameter two-stage light-gas gun

    SciTech Connect

    Susoeff, A R; Hawke, R S; Bowen, P R; Greenwood, D W; Marshall, F R

    1992-07-01

    a series of tests was conducted to determine the operating requirements needed to obtain maximum projectile velocity within the engineering design limits of a two-stage light-gas gun with a 7.6 mm (0.30 inch) diameter bore launch tube. The tests were conducted in a medium vacuum flight range. Previous experience with the gun was used to establish the minimum requirements for optimum efficiency. Two operating parameters, propellant load and drive gas pressure, were varied in order to find an initial optimum operating condition at a conservative propellant load. Propellant load and driver gas pressure were then incrementally increased. This procedure was methodically applied until significant mechanical deformation of a critical gun component took place. This report presents the results of these tests. Projectile velocity was measured to better than 3 percent accuracy using a magnetic induction technique. A 0.485 gram polycarbonate projectile was launched to a velocity of 7.77 km/s during the tests. 13 refs.

  16. Completion of evaluation of manufacturing processes for B/Al composites containing 0.2mm diameter boron fibers

    NASA Technical Reports Server (NTRS)

    Moore, T. J.; Moorhead, P. E.

    1980-01-01

    Four fabricators produced a total of 54 B/1100 Al, B/6061 Al, and B/2024 Al panels for evaluation. The 8 ply unidirectional, 45 to 50 volume percent, panels were made using 0.20 mm diameter boron fibers which were obtained from a single supplier. Hot press consolidation was carried out in vacuum except for one set of dry woven tape panels which were hot pressed in air. A single testing contractor conducted nondestructive inspection, metallography, fractography and mechanical property tests. The mechanical property tests included 21 and 260 C tensile tests and 21 C shear tests. Panel quality, as measured by nondestructive evaluation, was generally good as were the 21 C tensile properties. The panels hot pressed in air delaminated in the shear tests. Shear strength values were lower in these panels. But tensile strengths were not affected by the delaminations because of the relation between the tensile loading direction and the delaminations. Composite tensile strength was found to be proportional to the volume percent boron and the aluminum matrix rather than to the tape used or fabrication technique. Suitability of these composites for 260 C service was confirmed by tensile tests.

  17. High-speed intravascular spectroscopic photoacoustic imaging at 1000 A-lines per second with a 0.9-mm diameter catheter

    NASA Astrophysics Data System (ADS)

    Li, Yan; Gong, Xiaojing; Liu, Chengbo; Lin, Riqiang; Hau, William; Bai, Xiaosong; Song, Liang

    2015-06-01

    Intravascular spectroscopic photoacoustic technology can image atherosclerotic plaque composition with high sensitivity and specificity, which is critical for identifying vulnerable plaques. Here, we designed and engineered a catheter of 0.9 mm in diameter for intravascular photoacoustic (IVPA) imaging, smaller than the critical size of 1 mm required for clinical translation. Further, a quasifocusing photoacoustic excitation scheme was developed for the catheter, producing well-detectable IVPA signals from stents and lipids with a laser energy as low as ˜30 μJ/pulse. As a result, this design enabled the use of a low-energy, high-repetition rate, ns-pulsed optical parametric oscillator laser for high-speed spectroscopic IVPA imaging at both the 1.2-μm and 1.7-μm spectral bands for lipid detection. Specifically, for each wavelength, a 1-kHz IVPA A-line rate was achieved, ˜100-fold faster than previously reported IVPA systems offering a similar wavelength tuning range. Using the system, spectroscopic IVPA imaging of peri-adventitial adipose tissue from a porcine aorta segment was demonstrated. The significantly improved imaging speed, together with the reduced catheter size and multiwavelength spectroscopic imaging ability, suggests that the developed high-speed IVPA technology is of great potential to be further translated for in vivo applications.

  18. Low numbers of ovarian follicles ≥3 mm in diameter are associated with low fertility in dairy cows.

    PubMed

    Mossa, F; Walsh, S W; Butler, S T; Berry, D P; Carter, F; Lonergan, P; Smith, G W; Ireland, J J; Evans, A C O

    2012-05-01

    The total number of ovarian follicles ≥ 3mm in diameter (antral follicle count, AFC) during follicular waves varies among cattle of similar age, but AFC is highly repeatable within individuals. We hypothesized that lower AFC could be associated with reduced fertility in cattle. The AFC was assessed by ultrasonography for 2 d consecutively during the first wave of follicular growth of the estrous cycle, 4.6±1.43 d (mean ± SD) after estrus, in 306 Holstein-Friesian dairy cows approximately 70 d postpartum. Cows were classified into 3 groups based on AFC: low (AFC ≤15), intermediate (AFC=16 to 24), and high (AFC ≥25). During the cycle in which AFC was assessed and in subsequent cycles, cows were artificially inseminated (AI) following detection of estrus, and pregnancy status was assessed using ultrasonography. Cows with high AFC had 3.34 times greater odds of being pregnant at the end of the breeding season compared with cows with low AFC; the odds of a successful pregnancy at first service were 1.75 times greater in the intermediate compared with the low group. The predicted probability of a successful pregnancy by the end of the breeding period (length of breeding season was 86±16.3 d) was 94, 88, and 84% for the high, intermediate, and low AFC groups, respectively. No difference was evident among groups in 21-d submission rate (proportion of all cows detected in estrus and submitted for AI in the first 21 d of the breeding season), but the interval from calving to conception was shorter in the high (109.5±5.1 d) versus low (117.1±4 d) group, and animals with intermediate AFC received fewer services during the breeding season (2.3±0.1) compared with animals with low AFC (2.7±0.1). Lactating cows with ≤15 ovarian follicles have lower reproductive performance compared with cows with higher numbers of follicles, but the existence of a positive association between high numbers of ovarian follicles and fertility is yet to be established. PMID:22541464

  19. Preparative reversed-phase high-performance liquid chromatography collection efficiency for an antimicrobial peptide on columns of varying diameters (1 mm to 9.4 mm I.D.)

    PubMed Central

    Chen, Yuxin; Mant, Colin T.; Hodges, Robert S.

    2009-01-01

    The present study examines the effect of reversed-phase high-performance liquid chromatography (RP-HPLC) column diameter (1 mm to 9.4 mm I.D.) on the one-step slow gradient preparative purification of a 26-residue synthetic antimicrobial peptide. When taken together, the semi-preparative column (9.4 mm I.D.) provided the highest yields of purified product (an average of 90.7% recovery from hydrophilic and hydrophobic impurities) over a wide range of sample load (0.75–200 mg). Columns with smaller diameters, such as narrowbore columns (150 × 2.1 mm I.D.) and microbore columns (150 × 1.0 mm I.D.), can be employed to purify peptides with reasonable recovery of purified product but the range of the crude peptide that can be applied to the column is limited. In addition, the smaller diameter columns require more extensive fraction analysis to locate the fractions of pure product than the larger diameter column with the same load. Our results show the excellent potential of the one-step slow gradient preparative protocol as a universal method for purification of synthetic peptides. PMID:17156789

  20. Cav1.2 splice variant with exon 9* is critical for regulation of cerebral artery diameter

    PubMed Central

    Nystoriak, Matthew A.; Murakami, Kentaro; Penar, Paul L.

    2009-01-01

    L-type voltage-dependent Ca2+ channels (VDCCs) are essential for numerous processes in the cardiovascular and nervous systems. Alternative splicing modulates proteomic composition of Cav1.2 to generate functional variation between channel isoforms. Here, we describe expression and function of Cav1.2 channels containing alternatively spliced exon 9* in cerebral artery myocytes. RT-PCR showed expression of Cav1.2 splice variants both containing (α1C9/9*/10) and lacking (α1C9/10) exon 9* in intact rabbit and human cerebral arteries. With the use of laser capture microdissection and RT-PCR, expression of mRNA for both α1C9/9*/10 and α1C9/10 was demonstrated in isolated cerebral artery myocytes. Quantitative real-time PCR revealed significantly greater α1C9/9*/10 expression relative to α1C9/10 in intact rabbit cerebral arteries compared with cardiac tissue and cerebral cortex. To demonstrate a functional role for α1C9/9*/10, smooth muscle of intact cerebral arteries was treated with antisense oligonucleotides targeting α1C9/9*/10 (α1C9/9*/10-AS) or exon 9 (α1C-AS), expressed in all Cav1.2 splice variants, by reversible permeabilization and organ cultured for 1–4 days. Treatment with α1C9/9*/10-AS reduced maximal constriction induced by elevated extracellular K+ ([K+]o) by ∼75% compared with α1C9/9*/10-sense-treated arteries. Maximal constriction in response to the Ca2+ ionophore ionomycin and [K+]o EC50 values were not altered by antisense treatment. Decreases in maximal [K+]o-induced constriction were similar between α1C9/9*/10-AS and α1C-AS groups (22.7 ± 9% and 25.6 ± 4% constriction, respectively). We conclude that although cerebral artery myocytes express both α1C9/9*/10 and α1C9/10 VDCC splice variants, α1C9/9*/10 is functionally dominant in the control of cerebral artery diameter. PMID:19717733

  1. Percutaneous native renal biopsy: comparison of a 1.2-mm spring-driven system with a traditional 2-mm hand-driven system.

    PubMed

    Doyle, A J; Gregory, M C; Terreros, D A

    1994-04-01

    Over the last few years spring-driven mechanical biopsy guns have been introduced for performing renal biopsies. There has been little research done comparing these guns with traditional hand-driven needles in performing biopsies of native kidneys. We wished to compare our experience with the two needle types. We studied retrospectively the results and complication rates of 155 native kidney biopsies. Sixty-nine were performed with hand-driven 14-gauge needles and eighty-six with 18-gauge, spring-driven biopsy guns. Sufficient tissue for diagnosis was obtained in 96% of cases in the hand-driven group compared with 99% in the biopsy gun group (P = NS). Complications occurred in six cases in the hand-driven group compared with one case in the biopsy gun group (P = 0.02). As expected, the reported number of glomeruli per core in the 14-gauge cores was greater than in the 18-gauge cores (16.5 v 6.2, P < 0.01). This was partially offset by the greater number of passes made with the smaller needle. We conclude that similar results can be expected from both biopsy methods, with a possible slight decrease in complications using biopsy guns with smaller needle diameters. PMID:8154484

  2. Investigation of an 11mm diameter twin screw granulator: Screw element performance and in-line monitoring via image analysis.

    PubMed

    Sayin, Ridade; Martinez-Marcos, Laura; Osorio, Juan G; Cruise, Paul; Jones, Ian; Halbert, Gavin W; Lamprou, Dimitrios A; Litster, James D

    2015-12-30

    As twin screw granulation (TSG) provides one with many screw element options, characterization of each screw element is crucial in optimizing the screw configuration in order to obtain desired granule attributes. In this study, the performance of two different screw elements - distributive feed screws and kneading elements - was studied in an 11 mm TSG at different liquid-to-solid (L/S) ratios. The kneading element configuration was found to break large granules more efficiently, leading to narrower granule size distributions. While pharmaceutical industry shifts toward continuous manufacturing, inline monitoring and process control are gaining importance. Granules from an 11 mm TSG were analysed using the Eyecon™, a real-time high speed direct imaging system, which has been used to capture accurate particle size distribution and particle count. The size parameters and particle count were then assessed in terms of their ability to be a suitable control measure using the Shewhart control charts. d10 and particle count were found to be good indicators of the change in L/S ratio. However, d50 and d90 did not reflect the change, due to their inherent variability even when the process is at steady state. PMID:26385406

  3. 27 kHz Ultrasonic Complex Vibration Source Using (1, 1) Mode Transverse Vibration Disk with Multiple Transducers of 40 mm Diameter

    NASA Astrophysics Data System (ADS)

    Tsujino, Jiromaru; Ueoka, Tetsugi; Aoyama, Tohru; Karatsu, Ryohei; Kyuzen, Takafumi

    2007-07-01

    The configurations of a small-diameter 27 kHz ultrasonic complex vibration source using a (1,1)-mode transverse vibration disk with four bolt-clamped Langevin-type piezoelectric ceramic (PZT) transducers (BLTs) 40 mm in diameter is developed and studied. The vibration source is driven using two power amplifier systems and a circular vibration locus is obtained at a welding tip. A vibration amplitude of 8.5 μmp-0 (peak-to-zero value) is obtained at a driving voltage of 50 Vrms.

  4. 78 FR 41366 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 4 1/2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-10

    ... Proceedings: Assessment of Antidumping Duties, 68 FR 23954 (May 6, 2003). Unless we otherwise determine that... International Trade Administration Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure... antidumping duty order on certain large diameter carbon and alloy seamless standard, line, and pressure...

  5. Gas-phase NMR. Part I. Conformational energies of 1,2-disubstituted propanes and a comparison with MM2 and MNDO calculations

    NASA Astrophysics Data System (ADS)

    Miyajima, Takashi; Hirano, Tsuneo; Sato, Hisaya

    1984-11-01

    Gas-phase 1H NMR spectra of 1,2-dichloropropane (1,2-DCP) and 1,2-di(methoxy- d3)-propane (1,2-DMP) have been measured. The conformational energies of these molecules in the gas phase were determined from the observed coupling constants under a three rotational isomeric state model and are compared with the theoretical values from MM2 molecular mechanics and MNDO molecular orbital calculations. The results indicate that gas-phase NMR is useful method for the determination of conformational energies of relatively complex molecules, and that the MNDO results are more reasonable than the MM2 results for molecules containing electronegative atoms such as oxygen.

  6. Experimental verification of the feasibility of a 100 W class micro-scale gas turbine at an impeller diameter of 10 mm

    NASA Astrophysics Data System (ADS)

    Isomura, Kousuke; Murayama, Motohide; Teramoto, Susumu; Hikichi, Kousuke; Endo, Yuki; Togo, Shinichi; Tanaka, Shuji

    2006-09-01

    The feasibility of a 100 W class micro-scale gas turbine with a centrifugal impeller of 10 mm diameter has been studied by experimentally verifying the four major component performance requirements found from cycle analysis. The rotor is required to rotate at 870 000 rpm to generate the compressor pressure ratio 3, and it has successfully been achieved by using hydroinertia gas bearings. A compressor efficiency higher than that required by the target cycle has been measured. After correcting the effect of the heat leakage, approximately 65% of the compressor adiabatic efficiency is estimated to be achievable. The combustor has achieved stable self-sustained combustion at a combustion efficiency higher than 99.9%. The heat conduction analysis based on measured data showed that it is possible to keep the compressor below 170 °C when the turbine inlet temperature is 1050 °C. All four requirements are proven to be achievable, and hence, the feasibility of the micro-scale gas turbine at an impeller of 10 mm diameter has successfully been proven at component level.

  7. Value of Baseline Clinical and CT Characteristics for Predicting the Progression of Persistent Pure Ground-glass Nodule 10 mm or Less in Diameter.

    PubMed

    Wu, Fang; Cai, Zu-Long; Tian, Shu-Ping; Jin, Xin; Jing, Rui; Yang, Yue-Qing; Jin, Mei; Zhao, Shao-Hong

    2016-08-01

    Objective To explore the risk factors of the progression of persistent pure ground-glass nodule (pGGN) and make the risk stratification for pGGN 10 mm or less in diameter. Methods From June 2008 to April 2015,100 patients (108 lesions) with persistent pGGN≤10 mm in diameter were included in this study. Patients were followed up at least 1 year using thin-section computed tomography (CT). Patients' baseline clinical data and CT characteristics of pGGN were compared between progression group (size increased or/and solid component appeared) and non-progression group. Cox regression analysis was used to assess the relationship between clinical data,CT characteristics of pGGN,and lesion progression. The risk indices of lesion progression were calculated according to the results of Cox regression analysis and the relative factors of lung adenocarcinoma in previous studies. Logistic regression analysis was used to assess the relationship between risk indices and lesion progression. The optimal cutoff value was decided on receiver operating characteristic curve of risk indices and verified for predicting lesion progression. Results Fifteen of 108 lesions showed progression. The mean follow-up duration was (1016.36±486.00) days. There were statistically significant differences of lesion size,air bronchogram,and vessel changes between progression group and non-progression group (P=0.040,P=0.003,P=0.030,respectively).Lesion density (CT value≥-542.5 HU) and air bronchogram were the risk factors of lesion progression (P=0.003,P=0.021,respectively). The optimal cutoff value of total risk indices on predicting lesion progression was 4.25,with the sensitivity of 46.7%,specificity of 89.2%,and consistency of 83.3%. Conclusions CT value ≥-542.5 HU of pGGN and air bronchogram within lesion may predict lesion progression in persistent pGGN 10 mm or less in diameter. A risk index of less than 4.25 often suggests small probability of disease progression and thus a longer follow

  8. SIMBA survey of southern high-mass star forming regions. I. Physical parameters of the 1.2 mm/IRAS sources

    NASA Astrophysics Data System (ADS)

    Faúndez, S.; Bronfman, L.; Garay, G.; Chini, R.; Nyman, L.-Å.; May, J.

    2004-10-01

    We report the results of a 1.2 mm continuum emission survey toward 146 IRAS sources thought to harbour high-mass star forming regions. The sources have FIR colors typical of UCHII regions and were detected in the CS(2->1) line survey of Bronfman et al. (\\cite{bnm}). Regions of 15 arcmin × 10 arcmin, centered on each IRAS source, were mapped with an angular resolution of ˜24 arcsec, using the SIMBA array on the SEST telescope. 1.2 mm emission was detected toward all IRAS sources. We find that the dust cores associated with these sources have typical sizes of 0.4 pc and masses of 5× 103 M⊙. Dust temperatures and luminosities, derived from the SED, are typically 32 K and 2.3 × 105 L⊙. Table 1 and Figs. 6 to 23 are only available in electronic form at http://www.edpsciences.org

  9. ALMA Census of Faint 1.2 mm Sources Down to ~ 0.02 mJy: Extragalactic Background Light and Dust-poor, High-z Galaxies

    NASA Astrophysics Data System (ADS)

    Fujimoto, Seiji; Ouchi, Masami; Ono, Yoshiaki; Shibuya, Takatoshi; Ishigaki, Masafumi; Nagai, Hiroshi; Momose, Rieko

    2016-01-01

    We present statistics of 133 faint 1.2 mm continuum sources detected in about 120 deep Atacama Large Millimeter/submillimeter Array (ALMA) pointing data that include all the archival deep data available by 2015 June. We derive number counts of 1.2 mm continuum sources down to 0.02 mJy partly with the assistance of gravitational lensing, and find that the total integrated 1.2 mm flux of the securely identified sources is {22.9}-5.6+6.7 Jy deg-2 which corresponds to {104}-25+31% of the extragalactic background light (EBL) measured by Cosmic Background Explorer observations. These results suggest that the major 1.2 mm EBL contributors are sources with 0.02 mJy, and that very faint 1.2 mm sources with ≲0.02 mJy contribute negligibly to the EBL with the possible flattening and/or truncation of number counts in this very faint flux regime. To understand the physical origin of our faint ALMA sources, we measure the galaxy bias bg by the counts-in-cells technique, and place a stringent upper limit of bg < 3.5 that is not similar to bg values of massive distant red galaxies and submillimeter galaxies but comparable to those of UV-bright, star-forming BzK galaxies (sBzKs) and Lyman break galaxies (LBGs). Moreover, in the optical and near-infrared (NIR) deep fields, we identify optical-NIR counterparts for 59% of our faint ALMA sources, the majority of which have luminosities, colors, and the IRX-β relation the same as sBzKs and LBGs. We thus conclude that about a half of our faint ALMA sources are dust-poor, high-z galaxies as known as sBzKs and LBGs in optical studies, and that these faint ALMA sources are not miniature (U)LIRGs simply scaled down with the infrared brightness.

  10. Useful receiver telescope diameter of ground-based and airborne 1-, 2-, and 10-micron coherent lidars in the presence of atmospheric refractive turbulence

    NASA Technical Reports Server (NTRS)

    Chan, Kin P.; Killinger, Dennis K.

    1992-01-01

    Calculations of the integrated effect of atmospheric refractive turbulence on 1-, 2-, and 10-micron coherent lidar performance are presented for a series of different lidar propagation geometries. The effective lidar receiver telescope diameter is evaluated for each case. The results indicate that atmospheric turbulence should not be a significant factor in the performance of a downward-looking high-altitude or satellite-borne coherent lidar system. It is also shown that ground-based 1-2-micron coherent lidars may be limited in their useful telescope aperture, especially for horizontal or nearly horizontal path measurements near the ground.

  11. Influence of power density on high purity 63 mm diameter polycrystalline diamond deposition inside a 2.45 GHz MPCVD reactor

    NASA Astrophysics Data System (ADS)

    Yu, Shengwang; Wang, Rong; Zheng, Ke; Gao, Jie; Li, Xiaojing; Hei, Hongjun; Liu, Xiaoping; He, Zhiyong; Shen, Yanyan; Tang, Bin

    2016-09-01

    63 mm diameter polycrystalline diamond (PCD) films were synthesized via a microwave plasma chemical vapor deposition (MPCVD) reactor in 99% H2–1% CH4 atmosphere. Two different conditions, i.e. the typical condition (input power of 5 kW and gas pressure of 13 kPa) and the high power density condition (input power of 10 kW and gas pressure of 18 kPa), were employed for diamond depositions. The color changes of the plasma under the two proposed conditions with and without methane were observed by photographs. Likewise, the concentrations of hydrogen atoms and carbon active chemical species in plasma were analyzed by optical emission spectroscopy (OES). The morphologies and purity of the PCD films were investigated by scanning electron microscopy (SEM) and Raman spectroscopy, respectively. Finally, the transmission spectrum of the polished PCD plates was characterized by a UV–Vis–NIR spectrometer. Experimental results showed that both the concentrations of hydrogen atoms and carbon radicals increased obviously, with the boost input power and higher pressure. The films synthesized under the high power density condition displayed higher purity and more uniform thickness. The growth rates in 10 kW and 18 kPa reached ~7.7 µm h‑1, approximately 6.5 times as much as that occurred in the typical process. Moreover, the polished plates synthesized under the high power density condition possessed a relatively high optical transmittance (~69%), approaching the theoretical values of approximately 71.4% in IR. These results indicate that the purity and growth rate of big-area PCD films could be simultaneously increased with power density.

  12. Effect of Distribution of Basket-Hole Area on Simulated Altitude Performance of 25 1/2-Inch-Diameter Annular-Type Turbojet Combustor

    NASA Technical Reports Server (NTRS)

    Olson, Walter T.; Schroeter, Thomas T.

    1948-01-01

    A simulated altitude performance of a 25 1/2-inch-diameter annular-type turbojet combustor was performed to determine the effect of the distribution of basket-hole area on the altitude operational limits of the engine as imposed by the combustor.Total pressure drop was recorded, as well as the effect of fuel-nozzle flow capacity,and fuel-nozzle spray angle for one basket configuration. General observations were made for all configurations regarding flames, extent of afterburning, and durability of the baskets.

  13. Development of in vivo tissue-engineered microvascular grafts with an ultra small diameter of 0.6 mm (MicroBiotubes): acute phase evaluation by optical coherence tomography and magnetic resonance angiography.

    PubMed

    Ishii, Daizo; Enmi, Jun-Ichiro; Moriwaki, Takeshi; Ishibashi-Ueda, Hastue; Kobayashi, Mari; Iwana, Shinichi; Iida, Hidehiro; Satow, Tetsu; Takahashi, Jun C; Kurisu, Kaoru; Nakayama, Yasuhide

    2016-09-01

    Biotubes, i.e., in vivo tissue-engineered connective tubular tissues, are known to be effective as vascular replacement grafts with a diameter greater than several millimeters. However, the performance of biotubes with smaller diameters is less clear. In this study, MicroBiotubes with diameters <1 mm were prepared, and their patency was evaluated noninvasively by optical coherence tomography (OCT) and magnetic resonance angiography (MRA). MicroBiotube molds, containing seven stainless wires (diameter 0.5 mm) covered with silicone tubes (outer diameter 0.6 mm) per mold, were embedded into the dorsal subcutaneous pouches of rats. After 2 months, the molds were harvested with the surrounding capsular tissues to obtain seven MicroBiotubes (internal diameter 0.59 ± 0.015 mm, burst pressure 4190 ± 1117 mmHg). Ten-mm-long MicroBiotubes were allogenically implanted into the femoral arteries of rats by end-to-end anastomosis. Cross-sectional OCT imaging demonstrated the patency of the MicroBiotubes immediately after implantation. In a 1-month follow-up MRA, high patency (83.3 %, n = 6) was observed without stenosis, aneurysmal dilation, or elongation. Native-like vascular structure was reconstructed with completely endothelialized luminal surfaces, mesh-like elastin fiber networks, regular circumferential orientation of collagen fibers, and α-SMA-positive cells. Although the long-term patency of MicroBiotubes still needs to be confirmed, they may be useful as an alternative ultra-small-caliber vascular substitute. PMID:27003431

  14. VizieR Online Data Catalog: 70um-1.2mm and N2H+ maps of IRDC18454 (W43) (Beuther+,

    NASA Astrophysics Data System (ADS)

    Beuther, H.; Tackenberg, J.; Linz, H.; Henning, T.; Krause, O.; Ragan, S.; Nielbock, M.; Launhardt, R.; Schmiedeke, A.; Schuller, F.; Carlhoff, P.; Nguyen-Luong, Q.; Sakai, T.

    2011-11-01

    The cloud complex with a size of ~6'x6' was observed with PACS on Herschel on 2010 March 9. Maps at 250, 350, and 500um were obtained with SPIRE 2010) on 2010 March 11. We observed IRDC18454-1 with the Plateau de Bure Interferometer during five nights in October and November 2009 at 93GHz in the C and D configurations. The N2H+ data has been observed using the BEARS receiver at the NRO 45m telescope in Nobeyama, Japan. The different velocity components have been observed one in April 2010 with an average system temperature of Tsys=206K, the second in June, at slightly lower Tsys. The MIPS 24um data (from MIPSGAL) as well as the IRAC 8um observations (from GLIMPSE) are taken from the Spitzer archive. The 1.2mm continuum data were first presented in Beuther et al. (2002, Cat. J/ApJ/566/945) and the APEX 870um data are part of the ATLASGAL survey of the Galactic plane (Schuller et al., 2009A&A...504..415S). (2 data files).

  15. Non-invasive high-resolution tracking of human neuronal pathways: diffusion tensor imaging at 7T with 1.2 mm isotropic voxel size

    NASA Astrophysics Data System (ADS)

    Lützkendorf, Ralf; Hertel, Frank; Heidemann, Robin; Thiel, Andreas; Luchtmann, Michael; Plaumann, Markus; Stadler, Jörg; Baecke, Sebastian; Bernarding, Johannes

    2013-03-01

    Diffusion tensor imaging (DTI) allows characterizing and exploiting diffusion anisotropy effects, thereby providing important details about tissue microstructure. A major application in neuroimaging is the so-called fiber tracking where neuronal connections between brain regions are determined non-invasively by DTI. Combining these neural pathways within the human brain with the localization of activated brain areas provided by functional MRI offers important information about functional connectivity of brain regions. However, DTI suffers from severe signal reduction due to the diffusion-weighting. Ultra-high field (UHF) magnetic resonance imaging (MRI) should therefore be advantageous to increase the intrinsic signal-to-noise ratio (SNR). This in turn enables to acquire high quality data with increased resolution, which is beneficial for tracking more complex fiber structures. However, UHF MRI imposes some difficulties mainly due to the larger B1 inhomogeneity compared to 3T MRI. We therefore optimized the parameters to perform DTI at a 7 Tesla whole body MR scanner equipped with a high performance gradient system and a 32-channel head receive coil. A Stesjkal Tanner spin-echo EPI sequence was used, to acquire 110 slices with an isotropic voxel-size of 1.2 mm covering the whole brain. 60 diffusion directions were scanned which allows calculating the principal direction components of the diffusion vector in each voxel. The results prove that DTI can be performed with high quality at UHF and that it is possible to explore the SNT benefit of the higher field strength. Combining UHF fMRI data with UHF DTI results will therefore be a major step towards better neuroimaging methods.

  16. The ERK1/2 pathway participates in the upregulation of the expression of mesenteric artery α1 receptors by intravenous tail injections of mmLDL in mice.

    PubMed

    Wang, Jun-Jie; Chen, Xiao-Lan; Xu, Cang-Bao; Jiang, Gao-Feng; Lin, Jie; Liu, En-Qi; Qin, Xu-Ping; Li, Jie

    2016-02-01

    Minimally modified low density lipoprotein (mmLDL) is a risk factor for cardiovascular diseases. However, no studies examining the effect of mmLDL on vascular smooth muscle receptors have been released. The current study investigated the effect of mmLDL on the mesenteric artery α1 adrenoceptor and the molecular mechanisms. Mice were divided into the normal saline (NS), mmLDL, and mmLDL+U0126 groups. In the mmLDL+U0126 group, the animals were subjected to an intravenous tail injection of mmLDL and an intraperitoneal injection of U0126. Vascular tension caused by noradrenaline (NA) in mesenteric arteries was measured with a sensitive myograph system. The serum levels of oxLDL, TNF-α, and IL-1β were detected using enzyme-linked immunosorbent assays. The expressions of the α1 adrenoceptor, the α2 adrenoceptor, TNF-α, IL-1β, and pERK1/2 were detected using real-time polymerase chain reactions and Western blot analysis. Compared with the NS group, the mmLDL group exhibited a noticeably enhanced NA shrinkage dose-response curve and a significantly increased Emax value (P<0.01). Prazosin (α1 adrenoceptor antagonist) caused a noticeable right shift of the dose-response curve. U0126 inhibited the increases in the serum levels and vessel wall expression of IL-1β and TNF-α and enhanced the NA shrinkage dose-response curve caused by mmLDL, as observed by a significantly decreased Emax value (P<0.01). It inhibited the increased α1 adrenoceptor expression caused by mmLDL. The serum levels of IL-1β and TNF-α demonstrated a positive correlation with the NA-induced maximum shrinkage percentage. U0126 inhibited the mmLDL-induced increase in the pERK1/2 protein level in the vessel wall. In conclusion, mmLDL increased the serum levels of IL-1β and TNF-α in vivo by activating the ERK1/2 pathway, which resulted in α1 receptor-mediated vasoconstriction and an increase in the expression of α1 adrenoceptor. The results of this study may provide new ideas for the prevention

  17. Noise data from tests of a 1.83 meter (6-ft-) diameter variable-pitch 1.2-pressure-ratio fan (QF-9)

    NASA Technical Reports Server (NTRS)

    Glaser, F. W.; Wazyniak, J. A.; Friedman, R.

    1975-01-01

    Acoustic and aerodynamic data for a 1.83-meter (6-ft.) diameter fan suitable for a quiet engine for short-takeoff-and-landing (STOL) aircraft are documented. The QF-9 rotor blades had an adjustable pitch feature which provided a means for testing at several rotor blade setting angles, including one for reverse thrust. The fan stage incorporated features for low noise. Far-field noise around the fan was measured without acoustic suppression over a range of operating conditions for six different rotor blade setting angles in the forward thrust configuration, and for one in the reverse configuration. Complete results of one-third-octave band analysis of the data are presented in tabular form. Also included are power spectra, data referred to the source, and sideline perceived noise levels.

  18. Total hip replacement through a posterior approach using a 22 mm diameter femoral head : the role of the transverse acetabular ligament and capsular repair in reducing the rate of dislocation.

    PubMed

    Kumar, V; Sharma, S; James, J; Hodgkinson, J P; Hemmady, M V

    2014-09-01

    Despite a lack of long-term follow-up, there is an increasing trend towards using femoral heads of large diameter in total hip replacement (THR), partly because of the perceived advantage of lower rates of dislocation. However, increasing the size of the femoral head is not the only way to reduce the rate of dislocation; optimal alignment of the components and repair of the posterior capsule could achieve a similar effect. In this prospective study of 512 cemented unilateral THRs (Male:Female 230:282) performed between 2004 and 2011, we aimed to determine the rate of dislocation in patients who received a 22 mm head on a 9/10 Morse taper through a posterior approach with capsular repair and using the transverse acetabular ligament (TAL) as a guide for the alignment of the acetabular component. The mean age of the patients at operation was 67 years (35 to 89). The mean follow-up was 2.8 years (0.5 to 6.6). Pre- and post-operative assessment included Oxford hip, Short Form-12 and modified University of California Los Angeles and Merle D'Aubigne scores. The angles of inclination and anteversion of the acetabular components were measured using radiological software. There were four dislocations (0.78%), all of which were anterior. In conclusion, THR with a 22 mm diameter head performed through a posterior approach with capsular repair and using the TAL as a guide for the alignment of the acetabular component was associated with a low rate of dislocation. PMID:25183591

  19. Probing channel temperature profiles in Al{sub x}Ga{sub 1−x}N/GaN high electron mobility transistors on 200 mm diameter Si(111) by optical spectroscopy

    SciTech Connect

    Kyaw, L. M.; Bera, L. K.; Dolmanan, S. B.; Tan, H. R.; Bhat, T. N.; Tripathy, S.; Liu, Y.; Bera, M. K.; Singh, S. P.; Chor, E. F.

    2014-08-18

    Using micro-Raman and photoluminescence (PL) techniques, the channel temperature profile is probed in Al{sub x}Ga{sub 1-x}N/GaN high electron mobility transistors (HEMTs) fabricated on a 200 mm diameter Si(111) substrate. In particular, RuO{sub x}-based gate is used due to the semitransparent nature to the optical excitation wavelengths, thus allowing much accurate thermal investigations underneath the gate. To determine the channel temperature profile in devices subjected to different electrical bias voltages, the GaN band-edge PL peak shift calibration with respect to temperature is used. PL analyses show a maximum channel temperature up to 435 K underneath the gate edge between gate and drain, where the estimated thermal resistance in such a HEMT structure is about 13.7 KmmW{sup −1} at a power dissipation of ∼10 W/mm. The temperature profiles from micro-Raman measurements are also addressed from the E{sub 2}-high optical phonon peak shift of GaN, and this method also probes the temperature-induced peak shifts of optical phonon from Si thus showing the nature of thermal characteristics at the AlN/Si substrate interface.

  20. SU-D-19A-05: The Dosimetric Impact of Using Xoft Axxent® Electronic Brachytherapy Source TG-43 Dosimetry Parameters for Treatment with the Xoft 30 Mm Diameter Vaginal Applicator

    SciTech Connect

    Simiele, S; Micka, J; Culberson, W; DeWerd, L

    2014-06-01

    Purpose: A full TG-43 dosimetric characterization has not been performed for the Xoft Axxent ® electronic brachytherapy source (Xoft, a subsidiary of iCAD, San Jose, CA) within the Xoft 30 mm diameter vaginal applicator. Currently, dose calculations are performed using the bare-source TG-43 parameters and do not account for the presence of the applicator. This work focuses on determining the difference between the bare-source and sourcein- applicator TG-43 parameters. Both the radial dose function (RDF) and polar anisotropy function (PAF) were computationally determined for the source-in-applicator and bare-source models to determine the impact of using the bare-source dosimetry data. Methods: MCNP5 was used to model the source and the Xoft 30 mm diameter vaginal applicator. All simulations were performed using 0.84p and 0.03e cross section libraries. All models were developed based on specifications provided by Xoft. The applicator is made of a proprietary polymer material and simulations were performed using the most conservative chemical composition. An F6 collision-kerma tally was used to determine the RDF and PAF values in water at various dwell positions. The RDF values were normalized to 2.0 cm from the source to accommodate the applicator radius. Source-in-applicator results were compared with bare-source results from this work as well as published baresource results. Results: For a 0 mm source pullback distance, the updated bare-source model and source-in-applicator RDF values differ by 2% at 3 cm and 4% at 5 cm. The largest PAF disagreements were observed at the distal end of the source and applicator with up to 17% disagreement at 2 cm and 8% at 8 cm. The bare-source model had RDF values within 2.6% of the published TG-43 data and PAF results within 7.2% at 2 cm. Conclusion: Results indicate that notable differences exist between the bare-source and source-in-applicator TG-43 simulated parameters. Xoft Inc. provided partial funding for this work.

  1. A 90dB 1.32mW 1.2V 0.13mm2 Two-Stage Variable Gain Amplifier in 0.18μm CMOS

    NASA Astrophysics Data System (ADS)

    Duong, Quoc-Hoang; Lee, Jeong-Seon; Min, Sang-Hyun; Kim, Joong-Jin; Lee, Sang-Gug

    An all CMOS variable gain amplifier (VGA) which features wide dB-linear gain range per stage (45dB), low power consumption (1.32mW), small chip size (0.13mm2), and low supply voltage (1.2V) is described. The dB-linear range is extended by reducing the supply voltage of the conventional V-to-I converter. The two-stage VGA implemented in 0.18μm CMOS offers 90dB of gain variation, 3dB bandwidth of greater than 21MHz, and max/min input IP3 and P1 dB, respectively, of -5/-42 and -12/-50 dBm.

  2. Comparison of retrograde intrarenal surgery versus a single-session percutaneous nephrolithotomy for lower-pole stones with a diameter of 15 to 30 mm: A propensity score-matching study

    PubMed Central

    Jung, Gyoo Hwan; Jung, Jae Hyun; Ahn, Tae Sik; Lee, Joong Sub; Cho, Sung Yong; Jeong, Chang Wook; Lee, Seung Bae; Kim, Hyeon Hoe

    2015-01-01

    Purpose To investigate surgical outcomes between retrograde intrarenal surgery (RIRS) and percutaneous nephrolithotomy (PNL) groups for a main stone sized 15 to 30 mm and located in the lower-pole calyx. Materials and Methods Patients who underwent PNL or RIRS for a main stone sized 15 to 30 mm and located in the lower-pole calyx were retrospectively reviewed. Each patient in the RIRS group was matched to one in the PNL group on the basis of calculated propensity scores by use of age, sex, body mass index, previous treatment history, stone site, maximum stone size, and stone volume. We compared perioperative outcomes between the unmatched and matched groups. Results Patients underwent PNL (n=87, 66.4%) or RIRS (n=44, 33.6%). After matching, 44 patients in each group were included. Mean patient age was 54.4±13.7 years. Perioperative hemoglobin drop was significantly higher and the hospital stay was longer in the PNL group than in the RIRS group. The operative time was significantly longer in the RIRS group than in the PNL group. Stone-free rates were higher and complications rates were lower in the RIRS group than in the PNL group without statistical significance. The presence of a stone located in the lower-anterior minor calyx was a predictor of stone-free status. Conclusions RIRS and single-session PNL for patients with a main stone of 15 to 30 mm located in the lower-pole calyx showed comparable surgical results. However, RIRS can be performed more safely than PNL with less bleeding. Stones in the lower-anterior minor calyx should be carefully removed during these procedures. PMID:26175872

  3. Effects of Initial Pore Diameter on the Oil Absorption Behavior of Potato Chips during Frying Process.

    PubMed

    Li, Jinwei; Zhang, Tingting; Liu, Yuanfa; Fan, Liuping

    2016-01-01

    How initial pore diameter in materials affects oil absorption has been rarely studied up to now. Herein, we provided direct data evidence suggesting that the pore diameter prior to frying closely related to the oil absorption behavior. The pore had no significant effect on oil absorption of potato chips (p>0.05) when its diameter was 0.1 and 0.2 mm compared with the control. However, the oil absorption increased with the increasing of pore diameter when it was 0.3-1.2 mm. The oil absorption tended to be saturated at 0.9 mm pore diameter. In addition, we analyzed the moisture content, total oil (TO), surface oil (SO), penetrated surface oil (PSO) and structural oil (STO) contents of potato chips. The results when using palm oil showed that there was no significant difference in moisture, TO and STO contents of samples with pore diameter of 0.1 and 0.2 mm during the whole frying processing respectively compared with the control (p>0.05). When pore diameter was 0.3-1.2 mm, STO and TO contents significantly increased with the rising of the diameter (p<0.05). The SO content and PSO content dropped as increasing in frying time for the samples with different pore diameters. The equilibrium TO content of samples with 0.3-0.9 mm pore significantly increased with the rising of pore diameter, which was about 6.2-22.5% higher than that of the control. And there was no significant difference in the equilibrium TO contents of both samples of 1.2 mm and 0.9 mm pore (p>0.05). STO fraction gave the greatest contribution to the increment of oil absorption. PMID:27041514

  4. 8mm/16mm Movie-Making.

    ERIC Educational Resources Information Center

    Provisor, Henry

    The materials, techniques, and attitudes needed to make professional-quality movies using 8mm., super 8mm., and 16mm. amateur equipment are covered in this guide to movie-making. The pros and cons are discussed of the various makes and models of cameras and lenses. Other topics discussed are: exposure and lighting, choosing film, camera speed and…

  5. Graft Diameter matters in Hamstring ACL reconstruction

    PubMed Central

    Clatworthy, Mark

    2016-01-01

    Objective: Recently techniques have been developed to increase graft diameter in hamstring ACL reconstruction with the hope to decrease graft failure. To date there is limited evidence to show that a smaller graft diameter results in a higher ACL failure rate. Method: The factors for failure in 1480 consecutive single surgeon hamstring ACL reconstructions were evaluated prospectively. Patients were followed for 2-15 years. A multivariate analysis was performed which looked at graft size, age, sex, time to surgery, meniscal integrity, meniscal repair and ACL graft placement to determine whether graft diameter matters in determining the failure of hamstring ACL reconstruction. Results: Graft diameters ranged from 6-10 mm. The mean graft diameter for all patients was 7.75 mm. 83 ACL reconstructions failed. The mean size of graft failures was 7.55 mm ACL reconstructions that failed had a significantly smaller hamstring graft diameter p=0.001. The Hazard Ratio for a smaller diameter graft is 0.517 p=<0.0001. For every 1 mm decrease in graft diameter there is a 48.3% higher chance of failure. The multivariate analysis showed a hazard ratio of 0.543 p=0.002. For every 1 mm decrease in graft diameter there is a 45.7% higher chance of failure. Conclusion: Smaller diameter hamstring grafts do have a higher failure rate. Grafts ≤ 7.5 mm had twice the failure rate of grafts ≥8 mm using a multivariate analysis for every 1 mm decrease in graft diameter there is a 45.7% higher chance of failure.

  6. Finite Element Analysis of Bone Stress around Micro-Implants of Different Diameters and Lengths with Application of a Single or Composite Torque Force

    PubMed Central

    Lu, Ying-juan; Chang, Shao-hai; Ye, Jian-tao; Ye, Yu-shan; Yu, Yan-song

    2015-01-01

    Background Stress on the bone surrounding dental micro-implants affects implant success. Purpose To compare the stress on the bone surrounding a micro-implant after application of a single force (SF) of 200 g or a composite force (CF) of 200 g and 6 N.mm torque. Materials and Methods Finite element models were developed for micro-implant diameters of 1.2, 1.6, and 2.0 mm, and lengths of 6, 8, 10, and 12 mm and either a SF or CF was applied. The maximum equivalent stress (Max EQS) of the bone surrounding the micro-implant was determined, and the relationships among type of force, diameter, and length were evaluated. Results The Max EQS of the CF exceeded that of the SF (P< 0.05). The effect of force on stress was related to implant diameter, but not to implant length. The larger CF led to greater instability of the micro-implant and the effect was most pronounced at an implant diameter of 1.2 mm. The use of implant diameters of 1.6 mm and 2.0 mm produced no significant difference in implant stability when either a CF or SF was applied. Conclusion When considering the use of an implant to perform three-dimensional control on the teeth, the implant diameter chosen should be > 1.2 mm. PMID:26659581

  7. Study of temperature dependences of mechanical properties of large-diameter pipes

    NASA Astrophysics Data System (ADS)

    Ostsemin, A. A.; Saidov, G. I.

    1994-04-01

    The paper presents the results of an experimental determination of mechanical properties of large-diameter pipes of steels 09G2S, 14G2SAF, 17G1S and their welded joints at a strain rate of 200/s over a temperature range of 113-293 K. Microspecimens with the length of the working section being five times its diameter (1.2 mm) were used. Parameters of the yield stress temperature-and-rate dependence of V.D. Yaroshevich, as well as the lower critical transition temperature and fracture resistance were determined in relation to the ferrite diameter.

  8. The effect of initial diameter in sperically symmetric droplet combustion of sooting fuels

    NASA Technical Reports Server (NTRS)

    Jackson, G. S.; Avedisian, C. T.

    1994-01-01

    The effect of initial droplet diameter on the burning rate of sooting fuels - n-heptane and 1-chloro-octane - was examined experimentally at low gravity. A 1.2s drop tower provided a low gravity environment to minimize buoyancy and achieve spherically symmetric flames for stationary droplets. Free-floating and fiber-supported droplets were burned, and both techniques gave matching results for droplets of similar initial diameter. Burning rate constants for both fuels were measured for a large number of droplets ranging from 0.4 to 1.1mm in initial diameter.

  9. Implosion dynamics and x-ray generation in small-diameter wire-array Z pinches

    SciTech Connect

    Ivanov, V. V.; Sotnikov, V. I.; Kindel, J. M.; Hakel, P.; Mancini, R. C.; Astanovitskiy, A. L.; Haboub, A.; Altemara, S. D.; Shevelko, A. P.; Kazakov, E. D.; Sasorov, P. V.

    2009-05-15

    It is known from experiments that the radiated x-ray energy appears to exceed the calculated implosion kinetic energy and Spitzer resistive heating [C. Deeney et al., Phys. Rev. A 44, 6762 (1991)] but possible mechanisms of the enhanced x-ray production are still being discussed. Enhanced plasma heating in small-diameter wire arrays with decreased calculated kinetic energy was investigated, and a review of experiments with cylindrical arrays of 1-16 mm in diameter on the 1 MA Zebra generator is presented in this paper. The implosion and x-ray generation in cylindrical wire arrays with different diameters were compared to find a transition from a regime where thermalization of the kinetic energy is the prevailing heating mechanism to regimes with other dominant mechanisms of plasma heating. Loads of 3-8 mm in diameter generate the highest x-ray power at the Zebra generator. The x-ray power falls in 1-2 mm loads which can be linked to the lower efficiency of plasma heating with the lack of kinetic energy. The electron temperature and density of the pinches also depend on the array diameter. In small-diameter arrays, 1-3 mm in diameter, ablating plasma accumulates in the inner volume much faster than in loads of 12-16 mm in diameter. Correlated bubblelike implosions were observed with multiframe shadowgraphy. Investigation of energy balance provides evidence for mechanisms of nonkinetic plasma heating in Z pinches. Formation and evolution of bright spots in Z pinches were studied with a time-gated pinhole camera. A comparison of x-ray images with shadowgrams shows that implosion bubbles can initiate bright spots in the pinch. Features of the implosions in small-diameter wire arrays are discussed to identify mechanisms of energy dissipation.

  10. Effect of Crucible Diameter Reduction on the Convection, Macrosegregation, and Dendritic Morphology during Directional Solidification of Pb-2.2 Wt Pct Sb Alloy

    NASA Technical Reports Server (NTRS)

    Chen, Jun; Tewari, S. N.; Magadi, G.; DeGroh, H. C., III

    2003-01-01

    The Pb-2.2 wt pct Sb alloy has been directionally solidified in 1-, 2-, 3-, and 7-mm-diameter crucibles with planar and dendritic liquid-solid interface orphology. For plane front solidification, the experimentally observed macrosegregation along the solidified length follows the relationship proposed by Favier. Application of a 0.4 T transverse magnetic field has no effect on the extent of convection. Reducing the ampoule diameter appears to decrease the extent of convection. However, extensive convection is still present even in the 1-mm-diameter crucible. An extrapolation of the observed behavior indicated that nearly diffusive transport conditions require ampoules that are about 40 microns in diameter. Reduction of the crucible diameter does not appear to have any significant effect on the primary dendrite spacing. However, it results in considerable distortion of the dendrite morphology and ordering. This is especially true for the 1-mm diameter samples.

  11. mm-wave antenna

    NASA Astrophysics Data System (ADS)

    Muhs, H. P.

    1985-07-01

    The present low profile seeker front end's slotted waveguide antenna was primarily developed to investigate the feasibility of the application of standard manufacturing techniques to mm-wave hardware. A dual plane monopulse comparator was constructed to mate with the antenna via integrated packaging techniques. The comparator was fabricated by CAD/CAM milling operations.

  12. Interpreting stem diameter changes

    NASA Astrophysics Data System (ADS)

    Hölttä, T.; Sevanto, S.; Nikinmaa, E.

    2009-12-01

    Detecting phloem transport in stem diameter changes Teemu Hölttä1, Sanna Sevanto2, Eero Nikinmaa1 1Department of Forest Ecology, P.O. Box 27, FIN-00014 University of Helsinki, Finland 2Department of Physics, P.O. Box 48, FIN-00014 University of Helsinki, Finland Introduction The volume of living cells and xylem conduits vary according to pressures they are subjected to. Our proposition is that the behavior of the inner bark diameter variation which cannot be explained by changes in xylem water status arise from changes in the osmotic concentration of the phloem and cambial growth. Materials and methods Simultaneous xylem and stem diameter measurements were conducted between June 28th to October 4th 2006 in Southern Finland on a 47-year old, 15 meter tall, Scots pine tree (DBH 15 cm) at heights of 1.5 and 10 meters. The difference between the measured inner bark diameter and the inner bark diameter predicted from xylem diameter change with a simple model (assuming there was no change in the osmotic concentration of the phloem) is hypothesized to give the changes in the osmotic concentration of the inner bark. The simple model calculates the radial water exchange between the xylem and phloem driven by the water potential changes in the xylem. Results and Discussion The major signal in the inner bark diameter was the transpiration rate as assumed, but also a signal arising from the change in the osmotic concentration (Fig 1a). The predicted osmotic concentration of the phloem typically increased during the afternoon due to the loading of photosynthesized sugars to the phloem. Inner bark osmotic concentration followed the photosynthesis rate with a 3 and 4 hour time-lag at the top and base, respectively (Fig 1b). The connection between photosynthesis and the predicted change in phloem osmotic concentration was stronger in the upper part of the tree compared to lower part. The changes in the predicted osmotic concentration were not similar every day, indicating that

  13. Precision wire feeder for small diameter wire

    DOEpatents

    Brandon, E.D.; Hooper, F.M.; Reichenbach, M.L.

    1992-08-11

    A device for feeding small diameter wire having a diameter less than 0.04 mm (16 mil) to a welding station includes a driving wheel for controllably applying a non-deforming driving force to the wire to move the free end of the wire towards the welding station; and a tension device such as a torque motor for constantly applying a reverse force to the wire in opposition to the driving force to keep the wire taut. 1 figure.

  14. Precision wire feeder for small diameter wire

    DOEpatents

    Brandon, Eldon D.; Hooper, Frederick M.; Reichenbach, Marvin L.

    1992-01-01

    A device for feeding small diameter wire having a diameter less than 0.04 mm (16 mil) to a welding station includes a driving wheel for controllably applying a non-deforming driving force to the wire to move the free end of the wire towards the welding station; and a tension device such as a torque motor for constantly applying a reverse force to the wire in opposition to the driving force to keep the wire taut.

  15. Videodensitometry for measuring blood vessel diameter.

    PubMed

    Hoornstra, K; Hanselman, J M; Holland, W P; De Wey Peters, G W; Zwamborn, A W

    1980-01-01

    A method employing a special computer for determining the internal diameters of blood vessels from photofluorographic image is described; in vitro and in vivo experiments are performed with the system. The amount of contrast medium injected is restricted to 4 times 3 ml, and it is possible to determine the diameter (in the range from 2 to 16 mm) at any place where blood vessels can be catheterized. In the in vivo experiments the maximum systematic error is +/-5 percent in the 7 to 8 mm range. PMID:7424549

  16. Left Ventricular Diameter and Risk Stratification for Sudden Cardiac Death

    PubMed Central

    Narayanan, Kumar; Reinier, Kyndaron; Teodorescu, Carmen; Uy‐Evanado, Audrey; Aleong, Ryan; Chugh, Harpriya; Nichols, Gregory A.; Gunson, Karen; London, Barry; Jui, Jonathan; Chugh, Sumeet S.

    2014-01-01

    Background Left ventricular (LV) diameter is routinely measured on the echocardiogram but has not been jointly evaluated with the ejection fraction (EF) for risk stratification of sudden cardiac death (SCD). Methods and Results From a large ongoing community‐based study of SCD (The Oregon Sudden Unexpected Death Study; population ≈1 million), SCD cases were compared with geographic controls. LVEF and LV diameter, measured using the LV internal dimension in diastole (categorized as normal, mild, moderate, or severe dilatation using American Society of Echocardiography definitions) were assessed from echocardiograms prior but unrelated to the SCD event. Cases (n=418; 69.5±13.8 years), compared with controls (n=329; 67.7±11.9 years), more commonly had severe LV dysfunction (EF ≤35%; 30.5% versus 18.8%; P<0.01) and larger LV diameter (52.2±10.5 mm versus 49.7±7.9 mm; P<0.01). Moderate or severe LV dilatation (16.3% versus 8.2%; P=0.001) and severe LV dilatation (8.1% versus 2.1%; P<0.001) were significantly more frequent in cases. In multivariable analysis, severe LV dilatation was an independent predictor of SCD (odds ratio 2.5 [95% CI 1.03 to 5.9]; P=0.04). In addition, subjects with both EF ≤35% and severe LV dilatation had higher odds for SCD compared with those with low EF only (odds ratio 3.8 [95% CI 1.5 to 10.2] for both versus 1.7 [95% CI 1.2 to 2.5] for low EF only), suggesting that severe LV dilatation additively increased SCD risk. Conclusion LV diameter may contribute to risk stratification for SCD independent of the LVEF. This readily available echocardiographic measure warrants further prospective evaluation. PMID:25227407

  17. Double diameter boring tool

    DOEpatents

    Ashbaugh, F.A.; Murry, K.R.

    1986-02-10

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting flutes formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first flute tip to the axis of rotation plus the distance from the second flute tip to the axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second flute tip to the axis of rotation minus one-half the distance from the first flute tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.

  18. Double diameter boring tool

    DOEpatents

    Ashbaugh, Fred N.; Murry, Kenneth R.

    1988-12-27

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting edges formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first cutting edge tip to the axis of rotation plus the distance from the second cutting edge tip to the axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second cutting edge tip to the axis of rotation minus one-half the distance from the first cutting edge tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.

  19. The Energy Diameter Effect

    SciTech Connect

    Souers, P; Vitello, P; Garza, R; Hernandez, A

    2007-04-20

    Various relations for the detonation energy and velocity as they relate to the inverse radius of the cylinder are explored. The detonation rate-inverse slope relation seen in reactive flow models can be used to derive the familiar Eyring equation. Generalized inverse radii can be shown to fit large quantities of cylinder and sphere results. A rough relation between detonation energy and detonation velocity is found from collected JWL values. Cylinder test data for ammonium nitrate mixes down to 6.35 mm radii are presented, and a size energy effect is shown to exist in the Cylinder test data. The relation that detonation energy is roughly proportional to the square of the detonation velocity is shown by data and calculation.

  20. The Energy Diameter Effect

    SciTech Connect

    Vitello, P; Garza, R; Hernandez, A; Souers, P C

    2007-07-10

    We explore various relations for the detonation energy and velocity as they relate to the inverse radius of the cylinder. The detonation rate-inverse slope relation seen in reactive flow models can be used to derive the familiar Eyring equation. Generalized inverse radii can be shown to fit large quantities of cylinder results. A rough relation between detonation energy and detonation velocity is found from collected JWL values. Cylinder test data for ammonium nitrate mixes down to 6.35 mm radii are presented, and a size energy effect is shown to exist in the Cylinder test data. The relation that detonation energy is roughly proportional to the square of the detonation velocity is shown by data and calculation.

  1. Small diameter carbon nanopipettes

    NASA Astrophysics Data System (ADS)

    Singhal, Riju; Bhattacharyya, Sayan; Orynbayeva, Zulfiya; Vitol, Elina; Friedman, Gary; Gogotsi, Yury

    2010-01-01

    Nanoscale multifunctional carbon probes facilitate cellular studies due to their small size, which makes it possible to interrogate organelles within living cells in a minimally invasive fashion. However, connecting nanotubes to macroscopic devices and constructing an integrated system for the purpose of fluid and electrical signal transfer is challenging, as is often the case with nanoscale components. We describe a non-catalytic chemical vapor deposition based method for batch fabrication of integrated multifunctional carbon nanopipettes (CNPs) with tip diameters much smaller (10-30 nm) than previously reported (200 nm and above) and approaching those observed for multiwalled carbon nanotubes. This eliminates the need for complicated attachment/assembly of nanotubes into nanofluidic devices. Variable tip geometries and structures were obtained by controlled deposition of carbon inside and outside quartz pipettes. We have shown that the capillary length and gas flow rate have a marked effect on the carbon deposition. This gives us a flexible protocol, useful for growing carbon layers of different thicknesses at selective locations on a glass pipette to yield a large variety of cellular probes in bulk quantities. The CNPs possess an open channel for fluid transfer with the carbon deposited inside at 875 °C behaving like an amorphous semiconductor. Vacuum annealing of the CNP tips at temperatures up to 2000 °C yields graphitic carbon structures with an increase in conductivity of two orders of magnitude. Penetration of the integrated carbon nanoprobes into cells was shown to produce minimal Ca2+ signals, fast recovery of basal Ca2+ levels and no adverse activation of the cellular metabolism during interrogation times as long as 0.5-1 h.

  2. The diameters and number of nerve fibers in spinal nerve roots

    PubMed Central

    Liu, YongTao; Zhou, XiaoJi; Ma, Jun; Ge, YingBin; Cao, Xiaojian

    2015-01-01

    Objective To investigate the anatomical and histological features of spinal nerve roots and provide base data for neuroanastomosis therapy for paraplegia. Methods Spinal nerve roots from C1 to S5 were exposed on six adult cadavers. The diameter and the number of nerve fibers of each nerve root were measured, respectively, with a caliper and image analysis software. Results As for ventral roots, the diameter of C5 (2.50 ± 0.55 mm) was the largest in cervical segments. In thoracic and lumbosacral segments, the diameter gradually increased from T11 to S1 and then decreased from S1 to S5 except L3. S1 (1.43 ± 0.16 mm) was the thickest root and S5 (0.14 ± 0.02 mm) was the thinnest one. As for dorsal roots, the diameter of C7 (4.61 ± 0.87 mm) was the largest in cervical segments. From T11 to S1, the diameter increased and then decreased gradually from S1 to S5. The diameter of dorsal roots from T1 to S5 was largest at S1 (2.95 ± 0.57 mm) and smallest at S5 (0.27 ± 0.13 mm), respectively. C7 (8467 ± 1019), T12 (6538 ± 892), L3 (9169 ± 1160), and S1 (8253 ± 1419) ventral roots contained the most nerve fibers in cervical, thoracic, lumbar, and sacral segments, respectively. Similarly, C7 (39 653 ± 8458), T1 (26 507 ± 7617), L5 (34 455 ± 2740), and S1 (41 543 ± 3036) dorsal roots, respectively, contained the most nerve fibers in their corresponding segments. Conclusion The findings in the current study provided the imperative data and may be valuable for spinal nerve root microanastomosis surgery in the paraplegic patients. PMID:24605949

  3. Primeval galaxies in the sub-mm and mm

    NASA Technical Reports Server (NTRS)

    Bond, J. Richard; Myers, Steven T.

    1993-01-01

    Although the results of COBE's FIRAS experiment 1 constrain the deviation in energy from the CMB blackbody in the 500-5000 micron range to be delta E/E, sub cmb less than 0.005, primeval galaxies can still lead to a brilliant sub-mm sky of non-Gaussian sources that are detectable at 10 inch resolution from planned arrays such as SCUBA on the James Clerk Maxwell Telescope and, quite plausibly, at sub-arcsecond resolution in planned mm and sub-mm interferometers. Here, we apply our hierarchical peaks method to a CDM model to construct sub-mm and mm maps of bursting PG's appropriate for these instruments with minimum contours chosen to correspond to realistic observational parameters for them and which pass the FIRAS limits.

  4. Catastrophes of large diameter pipelines. The role of hydrogen fields

    SciTech Connect

    Polyakov, V.N.

    1995-09-01

    Fracture statistics on transmission pipelines is presented. Fractures of large-diameter pipelines are regarded as catastrophes. Fracture accidents of other pipes are less dangerous. Hydrogen makes outer layers of pipes brittle. Therefore, critical crack lengths for pipes have been calculated by a linear fracture mechanics technique. It was found that a crack of any length may be critical. The opposite opinion on reliable operation of large-diameter pipes (diameter 1420 mm) is discussed.

  5. The DIAMET campaign

    NASA Astrophysics Data System (ADS)

    Vaughan, G.

    2012-04-01

    DIAMET (DIAbatic influences on Mesoscale structures in ExTratropical storms) is a joint project between the UK academic community and the Met Office. Its focus is on understanding and predicting mesoscale structures in synoptic-scale storms, and in particular on the role of diabatic processes in generating and maintaining them. Such structures include fronts, rain bands, secondary cyclones, sting jets etc, and are important because much of the extreme weather we experience (e.g. strong winds, heavy rain) comes from such regions. The project conducted two field campaigns in the autumn of 2011, from September 14 - 30 and November 24 - December 14, based around the FAAM BAe146 aircraft with support from ground-based radar and radiosonde measurements. Detailed modelling, mainly using the Met Office Unified model, supported the planning and interpretation of these campaigns. This presentation will give a brief overview of the campaigns. Both in September and November-December the weather regime was westerly, with a strong jet stream directed across the Atlantic. Three IOPs were conducted in September, to observe a convective band ahead of an upper-level trough, waves on a long trailing cold front, and a warm conveyor belt associated with a secondary cyclone. In November-December six IOPs were conducted, to observe frontal passages and high winds. This period was notable for a number of very strong windstorms passing across the north of the UK, and gave us an opportunity to examine bent-back warm fronts in the southern quadrant of these storms where the strongest winds are found. The case studies fell into two basic patterns. In the majority of cases, dropsonde legs at high level were used to obtain a cross-section of winds and thermodynamic structure (e.g. across a front), followed by in situ legs at lower levels (generally where the temperature was between 0 and -10°) to examine microphysical processes, especially ice multiplication and the extent of supercooled water

  6. Characterization of Large Diameter PMTs for Kaon Cerenkov Detector

    NASA Astrophysics Data System (ADS)

    Boylan, Derek

    2014-09-01

    The 12 GeV upgrade at the Jefferson Laboratory allows for unique new opportunities to study hadron structure through kaon production in Hall C, a threshold aerogel detector was constructed at the Catholic University of America. It uses the emission of Cerenkov radiation at different indices of refraction ranging from 1.03 to 1.01 to distinguish pions, kaons, and protons. An important aspect of this detector is the collection of very small amounts of light, in particular as the aerogel refractive index decreases. The Hall C aerogel detector uses the Photonis XP4500 large-diameter photomultiplier tubes (PMT) in order to detect these small traces of light. The purpose of this project is to explore the performance of alternative large-diameter PMTs and compares them to that of the XP4500. The PMT uniformity across the photocathode was characterized through scans along the surface of the PMT with a low-intensity, focused LED, thereby creating a 3D image of the gain at each section. The method of scanning consists of a two axis step motor moving an LED light source on a 100 x 100 grid parallel to the face of the PMT, with 30 pulses of light from the LED at each step. The step motor scans with a resolution of 1.2 mm. Scans conducted in this manner result in high resolution images which pick up most sensitive/non-sensitive spots on the photocathode. In this presentation I will present the results of the characterization and performance test of the XP4500 and comparison to alternative large-diameter PMT models. The 12 GeV upgrade at the Jefferson Laboratory allows for unique new opportunities to study hadron structure through kaon production in Hall C, a threshold aerogel detector was constructed at the Catholic University of America. It uses the emission of Cerenkov radiation at different indices of refraction ranging from 1.03 to 1.01 to distinguish pions, kaons, and protons. An important aspect of this detector is the collection of very small amounts of light, in

  7. OpenMM accelerated MMTK

    NASA Astrophysics Data System (ADS)

    Bishop, Kevin P.; Constable, Steve; Faruk, Nabil F.; Roy, Pierre-Nicholas

    2015-06-01

    In this work, we provide an interface developed to link the Molecular Modelling toolkit (MMTK) with OpenMM in order to take advantage of the fast evaluation techniques of OpenMM. This interface allows MMTK scripts using the Langevin dynamics integrator, for both classical and path integral simulations, to be executed on a variety of hardware including graphical processing units via OpenMM. The interface has been developed using Python and Cython to take advantage of the high level abstraction thanks to the MMTK and OpenMM software packages. We have tested the interface on a number of systems to observe which systems benefit most from the acceleration libraries of OpenMM.

  8. Laser amplifier based on a neodymium glass rod 150 mm in diameter

    SciTech Connect

    Shaykin, A A; Fokin, A P; Soloviev, A A; Kuzmin, A A; Shaikin, I A; Burdonov, K F; Khazanov, E A; Charukhchev, A V

    2014-05-30

    A unique large-aperture neodymium glass rod amplifier is experimentally studied. The small-signal gain distribution is measured at different pump energies. The aperture-averaged gain is found to be 2.3. The stored energy (500 J), the maximum possible pump pulse repetition rate, and the depolarisation in a single pulse and in a series of pulses with a repetition rate of one pulse per five minutes are calculated based on the investigations performed. It is shown that the use of this amplifier at the exit of the existing laser can increase the output pulse energy from 300 to 600 J. (lasers)

  9. Pulling of 3 mm diameter AlSb rods by micro-pulling down method

    SciTech Connect

    Bourret-Courchesne Ph.D., Edith; Perrodin, Didier

    2009-05-14

    We designed and supplied special crucibles for AlSb material. Thermal insulation and limitation of Sb losses were our first work. The protection of the growth environment was also one of our priority to avoid any pollution of the Fibercryst {mu}PD facility. When this work was achieved, the next step was the calibration of the heating power for these new crucibles. Then, it was the definition of single crystal growth conditions that oriented our research. Following our proposal, many growths attempts were performed. We started from Al & Sb pure powder or from LBNL AlSb crystal as expected. We used different crucibles and different seeds.

  10. Initial experience with a new microlaparoscope 2 mm in external diameter.

    PubMed

    Downing, B G; Wood, C

    1995-05-01

    The microlaparoscope was used for diagnostic and operative purpose in 20 patients, including 6 GIFT and 2 microoperative procedures. No complications occurred and there was only 1 failure of the technique. Microlaparoscopy was performed successfully under local analgesia in 2 patients. The microlaparoscope may be safer and less traumatic than traditional laparoscopy. The technique is simple, effective and easy to learn. Its current place is mainly in diagnosis but with planned future improvement in instrumentation it will have a place in operative laparoscopy. PMID:7677691

  11. Monochromatic imaging studies of sustained metal vapor arcs burning on 150 mm diameter molten iron electrodes

    SciTech Connect

    Williamson, R.L.; Schlienger, M.E.

    1996-07-01

    Monochromatic imaging was used to investigate the excited-state density distributions of Fe and Fe{sup +} in the inter-electrode gap region of a 3,100 A dc metal vapor arc burning between molten iron surfaces in a vacuum arc furnace. Multiple images were acquired at four wavelengths. The images were corrected and Abel inverted to yield the absolute radial intensity distributions for Fe and Fe{sup +} in the inter-electrode gap region. The results show a structured, axisymmetric plasma consisting of a high density `core` of Fe{sup +} emitters centered between the electrode surfaces situated against a relatively broad, flat excited-state Fe distribution.

  12. TECHNICAL NOTE: Characteristic analysis of an ultrasonic micromotor using a 3 mm diameter piezoelectric rod

    NASA Astrophysics Data System (ADS)

    Chu, Xiangcheng; Yan, Li; Li, Longtu

    2004-04-01

    Smart systems and devices generally use certain microstructures, e.g. rod- and strip-shaped structures. In this paper, a miniaturized piezoelectric rod is analysed using the finite element method (FEM) and a laser scanning vibrometer (LSV). The effects of some factors, including the detailed structure, material parameters and input voltage, on the resonant frequencies and vibration behaviors of a piezoelectric rod are studied. On the basis of experimental results, the vibration modes of the piezoelectric rod can be made available for use in fabricating an ultrasonic micromotor or piezoelectric actuators of other types. The prototype motor fabricated here has a maximum output torque of 410 µN m for a stainless steel stator and 360 µN m for a copper stator. This article was originally published in 2003 by the Israel Academy of Sciences and Humanities in the framework of its Albert Einstein Memorial Lectures series. Reprinted by permission of the Israel Academy of Sciences and Humanities.

  13. SSC 40 mm cable results and 50 mm design discussions

    SciTech Connect

    Christopherson, D.; Capone, D.; Hannaford, R.; Remsbottom, R.; Jayakumar, R.; Snitchler, G. ); Scanlan, R.; Royet, J. )

    1990-09-01

    A summary of the cable produced for the 1990 40 mm Dipole Program is presented. The cable design parameters for the 50 mm Dipole Program are discussed, as well as portions of the SSC specification draft. Considerations leading to the final cable configuration and the results of preliminary trials are included. The first iteration of a strand mapping program to automate cable strand maps is introduced. 7 refs., 2 figs., 1 tab.

  14. Comparison of Failure Thickness and Critical Diameter of Nitromethane

    NASA Astrophysics Data System (ADS)

    Petel, Oren E.; Higgins, Andrew J.

    2006-07-01

    The critical diameter and failure thickness of both neat liquid nitromethane and a 65% nitromethane/35% nitroethane blend confined by aluminum are determined experimentally. A comparison of these two parameters provides insight into the failure mechanism of detonation in these explosives. If the failure of detonation in a critical charge diameter (or thickness) experiment is due to reaction quenching resulting from expansion losses (wave curvature), then it is expected that the failure thickness should be half the value of the critical diameter. The critical diameter and failure thickness of neat nitromethane confined in aluminum are found to be 2.5 mm and 0.75 mm respectively for a temperature range of 26 ± 1°C. The critical diameter and failure thickness of the 65NM/35NE blend confined in aluminum are found to be 6.2 mm and 1.7 mm respectively for a temperature range of 28 ± 1°C. The ratio of critical diameter to failure thickness for these experiments is found to lie between 3:1 and 4:1 rather than 2:1 as expected from wave curvature theory. By comparing the experimentally determined values of critical diameter and thickness for the test explosives and examining the failure patterns recovered on witness plates, a mechanism of propagation in thin rectangular channels is proposed based on complex wave interactions.

  15. [Effect of sharpening filter on vessel diameter measured by quantitative coronary arteriography].

    PubMed

    Arai, Hiroaki; Hosonuma, Naoya; Gou, Misako; Ueno, Takashi

    2002-05-01

    At cardiac catheterization, analog images obtained using cinefilm are translated into digital images, and images appearing on the CRT are filtered by a sharpen filter. We investigated the effect of the sharpening filter on vessel diameter as measured by quantitative coronary arteriography. We acquired images of a vessel phantom filled with contrast material using an X-ray image intensifier. Vessel diameters measured by quantitative coronary arteriography were 1 mm, 1.5 mm, 2 mm, 3 mm, 4 mm, and 6 mm. Results showed that vessel diameters were decreased when the sharpening filter was used and that more intense filtering decreased the measured diameter further. When the diameter of the vessel phantom was less than 4 mm, the diameter was smaller and the ratio of decrease was larger. Vessel diameters of 2 mm, 3 mm, 4 mm, and 6 mm measured a maximum of 2.9 smaller, while those of 1 mm and 1.5 mm measured a maximum of 9.2 smaller. PMID:12520240

  16. Suspected melanoma only when the lesion is greater than 6mm may harm patients

    PubMed Central

    de Oliveira, Renato Santos; de Oliveira, Daniel Arcuschin; Souza, Murilo Costa; da Silva, Mariane; Brandão, Mireille Darc Cavalcanti

    2015-01-01

    ABSTRACT Objective To analyze the distribution of larger diameter in the pathological report of cutaneous melanoma patients. Methods Data were obtained from patients seen from 1994 to 2015. Date, sex, age, maximum diameter, histological subtype, primary site, microscopic thickness, mitoses, ulceration, vertical growth phase, and regression were the variables studied. This study was approved by the National Ethics Committee - Brazil Platform. Patients were grouped into smaller diameter (≤6mm) and larger diameter (>6mm). The statistical analysis used the χ2 test (p<0.05). Results Of the 292 patients analyzed, 123 were seen between 1994 and 2004, and 169 between 2005 and 2015; in that, 151 women and 141 men, mean age of 52 years. The diameters ranged from 2 to 76mm (mean of 14mm), 81 patients with smaller diameter (≤6mm) and 211 with larger diameter (>6mm). Out of 81 patients with smaller diameter, 29 had invasive melanoma, while 179 of the 211 with larger diameter were invasive. A difference was observed in frequency of vertical growth phase. Conclusion Pigmented skin lesions with diameter smaller than 6mm should not be an excluding factor for biopsies, especially when patients present risk of developing skin cancer. PMID:26761547

  17. Estimate of the diameter of surface defects on a pattern specimen made of Plexiglas through active infrared thermography

    NASA Astrophysics Data System (ADS)

    Medina-Barreto, M. H.; Giraldo, J. M.; Ramírez-Hurtado, A. L.; Llamosa, L.; Cruz, B.

    2016-02-01

    In recent years the use of Infrared Thermography (IRT) has reached a special importance in the industrial sector as a method of Non-Destructive Testing (NDT), for inspection of surface and subsurface defects of different types of materials. In order to determine the size of such defects by implementing the technique of Infrared Active Thermography, a Plexiglass sample (PMMA) with circular defects of different diameters and depths was designed and built. The sample was thermally stimulated by a continuous radiation from a halogen lamp, and subsequently the thermographic images were acquired by using the time-resolved infrared radiometry technique (TRIR). Images were obtained using Fluke TI-30 and TI-32 cameras, and a program was designed in Matlab for its further processing. Through a user interface, the program can display and filter the image; then it chooses a particular defect and calculates the diameter with their respective uncertainties. The best results for the calculated diameter were obtained with Ti-32 camera. The estimated uncertainties were below of 1.2mm, regard of defect diameter. Importantly, uncertainties grew when the diameter/depth ratio was 1 for depths of 4.0mm.

  18. Wheel Diameter and Speedometer Reading

    ERIC Educational Resources Information Center

    Murray, Clifton

    2010-01-01

    Most introductory physics students have seen vehicles with nonstandard wheel diameters; some may themselves drive "low-rider" cars or "big-wheel" pickup trucks. But how does changing wheel diameter affect speedometer readout for a given speed? Deriving the answer can be followed readily by students who have been introduced to rotation, and it…

  19. Mechanical analysis of conventional and small diameter conical implant abutments

    PubMed Central

    Moris, Izabela Cristina Maurício; Faria, Adriana Cláudia Lapria; de Mattos, Maria da Gloria Chiarello; Ribeiro, Ricardo Faria

    2012-01-01

    PURPOSE The aim of the present study was to evaluate if a smaller morse taper abutment has a negative effect on the fracture resistance of implant-abutment connections under oblique compressive loads compared to a conventional abutment. MATERIALS AND METHODS Twenty morse taper conventional abutments (4.8 mm diameter) and smaller abutments (3.8 mm diameter) were tightened (20 Ncm) to their respective implants (3.5 × 11 mm) and after a 10 minute interval, implant/abutment assemblies were subjected to static compressive test, performed in a universal test machine with 1 mm/min displacement, at 45° inclination. The maximum deformation force was determined. Data were statistically analyzed by student t test. RESULTS Maximum deformation force of 4.8 mm and 3.8 mm abutments was approximately 95.33 kgf and 95.25 kgf, respectively, but no fractures were noted after mechanical test. Statistical analysis demonstrated that the evaluated abutments were statistically similar (P=.230). CONCLUSION Abutment measuring 3.8 mm in diameter (reduced) presented mechanical properties similar to 4.8 mm (conventional) abutments, enabling its clinical use as indicated. PMID:22977724

  20. Five meter diameter conical furlable antenna

    NASA Technical Reports Server (NTRS)

    Fortenberry, J. W.; Freeland, R. E.; Moore, D. M.

    1976-01-01

    An investigation was made to demonstrate that a 5-meter-diameter, furlable, conical reflector antenna utilizing a line source feed can be fabricated utilizing composite materials and to prove that the antenna can function mechanically and electrically as prototype flight hardware. The design, analysis, and testing of the antenna are described. An RF efficiency of 55% at 8.5 GHz and a surface error of 0.64 mm rms were chosen as basic design requirements. Actual test measurements yielded an efficiency of 53% (49.77 dB gain) and a surface error of 0.61 mm rms. Atmospherically induced corrosion of the reflector mesh resulted in the RF performance degradation. An assessment of the antenna as compared to the current state of the art technology was made. This assessment included cost, surface accuracy and RF performance, structural and mechanical characteristics, and possible applications.

  1. The GBT 4mm Receiver

    NASA Astrophysics Data System (ADS)

    Frayer, David T.; White, S.; Watts, G.; Stennes, M.; Maddalena, R. J.; Simon, R.; Pospieszalski, M.; Bryerton, E.

    2013-01-01

    The new 4mm receiver (67--93 GHz) for the Robert C. Byrd Green Bank Telescope (GBT) was built to take advantage of the improved surface accuracy of the dish. The low frequency end of the 3mm atmospheric window is not available with ALMA (<84 GHz), and the sensitivity of the GBT is better than any other facility within this band. We discuss the design and performance of this new receiver for the GBT, and highlight the science opportunities available with the instrument. The National Radio Astronomy Observatory is a facility of the National Science Foundation operated under cooperative agreement by Associated Universities, Inc.

  2. 1,2-Dichloropropane

    Integrated Risk Information System (IRIS)

    1,2 - Dichloropropane ; CASRN 78 - 87 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinoge

  3. 1,2-Dichloroethane

    Integrated Risk Information System (IRIS)

    1,2 - Dichloroethane ; CASRN 107 - 06 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinoge

  4. 1,2-Diphenylhydrazine

    Integrated Risk Information System (IRIS)

    1,2 - Diphenylhydrazine ; CASRN 122 - 66 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcin

  5. 1,2-Dichlorobenzene

    Integrated Risk Information System (IRIS)

    1,2 - Dichlorobenzene ; CASRN 95 - 50 - 1 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinoge

  6. 1,2-Dibromoethane

    Integrated Risk Information System (IRIS)

    1,2 - Dibromoethane ; CASRN 106 - 93 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogen

  7. Apollo 12 photography 70 mm, 16 mm, and 35 mm frame index

    NASA Technical Reports Server (NTRS)

    1970-01-01

    For each 70-mm frame, the index presents information on: (1) the focal length of the camera, (2) the photo scale at the principal point of the frame, (3) the selenographic coordinates at the principal point of the frame, (4) the percentage of forward overlap of the frame, (5) the sun angle (medium, low, high), (6) the quality of the photography, (7) the approximate tilt (minimum and maximum) of the camera, and (8) the direction of tilt. A brief description of each frame is also included. The index to the 16-mm sequence photography includes information concerning the approximate surface coverage of the photographic sequence and a brief description of the principal features shown. A column of remarks is included to indicate: (1) if the sequence is plotted on the photographic index map and (2) the quality of the photography. The pictures taken using the lunar surface closeup stereoscopic camera (35 mm) are also described in this same index format.

  8. Three-dimensional finite element analysis of stress distribution in a tooth restored with metal and fiber posts of varying diameters: An in-vitro study

    PubMed Central

    Kumar, Pradeep; Rao, R. Nageswar

    2015-01-01

    Objective: To compare stress distribution in a tooth restored with metal and fiber posts of varying diameters (1.2 and 1.4 mm) by means of three-dimensional finite element analysis (3D-FEA). Materials and Methods: Four 3D-FEA models were constructed: (1) fiber post (1.2 and 1.4 mm) and (2) metal post (1.2 and 1.4 mm). The material properties were assigned and a force of 100 N was applied at 45° angle to the longitudinal axis of the tooth onto the palatal surface incisal to the cingulum. Analysis was run and stress distribution pattern was studied. Results: Maximum stresses in the radicular tooth structure for fiber post were higher than that for metal post. In the former models, stresses in the tooth structure were slightly reduced with increase in fiber post diameter. Conclusions: To reduce stress in the remaining radicular tooth structure, it is better to use a fiber post of a large diameter. PMID:25829685

  9. Measuring Diameters Of Large Vessels

    NASA Technical Reports Server (NTRS)

    Currie, James R.; Kissel, Ralph R.; Oliver, Charles E.; Smith, Earnest C.; Redmon, John W., Sr.; Wallace, Charles C.; Swanson, Charles P.

    1990-01-01

    Computerized apparatus produces accurate results quickly. Apparatus measures diameter of tank or other large cylindrical vessel, without prior knowledge of exact location of cylindrical axis. Produces plot of inner circumference, estimate of true center of vessel, data on radius, diameter of best-fit circle, and negative and positive deviations of radius from circle at closely spaced points on circumference. Eliminates need for time-consuming and error-prone manual measurements.

  10. Wheel Diameter and Speedometer Reading

    NASA Astrophysics Data System (ADS)

    Murray, Clifton

    2010-09-01

    Most introductory physics students have seen vehicles with nonstandard wheel diameters; some may themselves drive "low-rider" cars or "big-wheel" pickup trucks. But how does changing wheel diameter affect speedometer readout for a given speed? Deriving the answer can be followed readily by students who have been introduced to rotation, and it makes a good illustration of how reasoning in physics can lead to a result that is useful outside the classroom.

  11. Variable Selection using MM Algorithms

    PubMed Central

    Hunter, David R.; Li, Runze

    2009-01-01

    Variable selection is fundamental to high-dimensional statistical modeling. Many variable selection techniques may be implemented by maximum penalized likelihood using various penalty functions. Optimizing the penalized likelihood function is often challenging because it may be nondifferentiable and/or nonconcave. This article proposes a new class of algorithms for finding a maximizer of the penalized likelihood for a broad class of penalty functions. These algorithms operate by perturbing the penalty function slightly to render it differentiable, then optimizing this differentiable function using a minorize-maximize (MM) algorithm. MM algorithms are useful extensions of the well-known class of EM algorithms, a fact that allows us to analyze the local and global convergence of the proposed algorithm using some of the techniques employed for EM algorithms. In particular, we prove that when our MM algorithms converge, they must converge to a desirable point; we also discuss conditions under which this convergence may be guaranteed. We exploit the Newton-Raphson-like aspect of these algorithms to propose a sandwich estimator for the standard errors of the estimators. Our method performs well in numerical tests. PMID:19458786

  12. Stellar diameters and temperatures. IV. Predicting stellar angular diameters

    SciTech Connect

    Boyajian, Tabetha S.; Van Belle, Gerard; Von Braun, Kaspar

    2014-03-01

    The number of stellar angular diameter measurements has greatly increased over the past few years due to innovations and developments in the field of long baseline optical interferometry. We use a collection of high-precision angular diameter measurements for nearby, main-sequence stars to develop empirical relations that allow the prediction of stellar angular sizes as a function of observed photometric color. These relations are presented for a combination of 48 broadband color indices. We empirically show for the first time a dependence on metallicity of these relations using Johnson (B – V) and Sloan (g – r) colors. Our relations are capable of predicting diameters with a random error of less than 5% and represent the most robust and empirical determinations of stellar angular sizes to date.

  13. Femoral head diameter considerations for primary total hip arthroplasty.

    PubMed

    Girard, J

    2015-02-01

    The configuration of total hip arthroplasty (THA) implants has constantly evolved since they were first introduced. One of the key components of THA design is the diameter of the prosthetic femoral head. It has been well established that the risk of dislocation is lower as the head diameter increases. But head diameter impacts other variables beyond joint stability: wear, cam-type impingement, range of motion, restoration of biomechanics, proprioception and groin pain. The introduction of highly cross-linked polyethylene and hard-on-hard bearings has allowed surgeons to implant large-diameter heads that almost completely eliminate the risk of dislocation. But as a result, cup liners have become thinner. With femoral head diameters up to 36 mm, the improvement in joint range of motion, delay in cam-type impingement and reduction in dislocation risk have been clearly demonstrated. Conversely, large-diameter heads do not provide any additional improvements. If an "ecologically sound" approach to hip replacement is embraced (e.g. keeping the native femoral head diameter), hip resurfacing with a metal-on-metal bearing must be carried out. The reliability of large-diameter femoral heads in the longer term is questionable. Large-diameter ceramic-on-ceramic bearings may be plagued by the same problems as metal-on-metal bearings: groin pain, squeaking, increased stiffness, irregular lubrication, acetabular loosening and notable friction at the Morse taper. These possibilities require us to be extra careful when using femoral heads with a diameter greater than 36 mm. PMID:25596984

  14. Ultrahigh-resolution and non-contact diameter measurement of metallic wire using eddy current sensor.

    PubMed

    Li, Wei; Wang, Hongbo; Feng, Zhihua

    2014-08-01

    This paper proposes a new method using eddy current sensor (ECS) for online non-contact diameter measurement of metallic wires with ultrahigh resolution. A prototype sensor was designed, fabricated, and tested for copper wires with diameters ranging from 1.12 mm to 1.30 mm. A solenoid coil with dimensions of 16 mm long and 2.1 mm in diameter is used as sensing element with a working frequency of 1.3 MHz. With a well-designed bridge, the sensing coil's inductance variation can be detected and the wire's diameter can be calculated. The ECS system demonstrated a dynamic resolution better than 2.2 μm and a static resolution better than 0.42 nm for a wire with a diameter of 1.3 mm. This non-contact method has competitive advantages over other methods in many aspects, especially in terms of measurement resolution. PMID:25173300

  15. High voltage variable diameter insulator

    DOEpatents

    Vanacek, D.L.; Pike, C.D.

    1982-07-13

    A high voltage feedthrough assembly having a tubular insulator extending between the ground plane ring and the high voltage ring. The insulator is made of Pyrex and decreases in diameter from the ground plane ring to the high voltage ring, producing equipotential lines almost perpendicular to the wall of the insulator to optimize the voltage-holding capability of the feedthrough assembly.

  16. High energy electrons from interaction with a 10 mm gas-jet at FLAME

    NASA Astrophysics Data System (ADS)

    Grittani, G. M.; Anania, M. P.; Gatti, G.; Giulietti, D.; Kando, M.; Krus, M.; Labate, L.; Levato, T.; Oishi, Y.; Rossi, F.; Gizzi, L. A.

    2013-05-01

    In this paper we discuss the spectra of the electrons produced in the laser-plasma acceleration experiment at FLAME. Here a <30 fs laser pulse is focused via an f/10 parabola in a focal spot of 10 μm diameter into a 1.2 mm by 10 mm rectangular Helium gas-jets at a backing pressure ranging from 5 to 15 bar. The intensity achieved exceeds 1019 Wcm -2. In our experiment the laser is set to propagate in the gas-jet along the longitudinal axis to use the 10 mm gas-jet length and to evaluate the role of density gradients. The propagation of the laser pulse in the gas is monitored by means of a Thomson scattering optical imaging. Accelerated electrons are set to propagate for 47,5 cm before being detected by a scintillating screen to evaluate bunch divergence and pointing. Alternatively, electrons are set to propagate in the field of a magnetic dipole before reaching the scintillating screen in order to evaluate their energy spectrum. Our experimental data show highly collimated bunches (<1 mrad) with a relatively stable pointing direction (<10 mrad). Typical bunch electron energy ranges between 50 and 200 MeV with occasional exceptional events of higher energy up to 1GeV.

  17. Decrease rate of the renal diameter in chronic hemodialysis patients.

    PubMed

    Aoyagi, Teiichiro; Tachibana, Masaaki; Naganuma, Shinji

    2013-01-01

    We here present the results of ultrasonographic (US) evaluations on the alteration of renal diameter of chronic HD patients. Of 109 outpatient HD patients who had neither severe acquired cystic disease of the kidney nor hereditary polycystic kidney disease, we performed US two or three times to measure their maximum renal diameter (mean of both kidneys), and the yearly alteration rate was calculated. The average interval of the two measurements was 35.9 months, and the average HD duration from the HD induction to the first measurement was 29.5 months. The average decrease rate of renal diameter was 4.34 ± 0.4 (SE) mm/year. No statistical difference was seen on the decrease rate in relation to gender, age and original disease (among three groups, glomerulonephritis and IgA nephropathy, diabetes, and others including hypertension). However, the decrease rate was large when the first measurement was close to the induction of hemodialysis, suggesting that the alteration rate reduced according to the hemodialysis vintage (5.3 ± 0.8 mm/year, first measurement not more than 10 months after induction of HD and 1.5 ± 1.6 mm/year, first measurement more than 80 months after induction of HD). Renal diameter decreased approximately 4.3 mm each year, and the decrease rate slowed as the length of time on dialysis increased. PMID:24967236

  18. Dehalogenimonas spp. can Reductively Dehalogenate High Concentrations of 1,2-Dichloroethane, 1,2-Dichloropropane, and 1,1,2-Trichloroethane

    PubMed Central

    2012-01-01

    The contaminant concentrations over which type strains of the species Dehalogenimonas alkenigignens and Dehalogenimonas lykanthroporepellens were able to reductively dechlorinate 1,2-dichloroethane (1,2-DCA), 1,2-dichloropropane (1,2-DCP), and 1,1,2-trichloroethane (1,1,2-TCA) were evaluated. Although initially isolated from an environment with much lower halogenated solvent concentrations, D. alkenigignens IP3-3T was found to reductively dehalogenate chlorinated alkanes at concentrations comparable to D. lykanthroporepellens BL-DC-9T. Both species dechlorinated 1,2-DCA, 1,2-DCP, and 1,1,2-TCA present at initial concentrations at least as high as 8.7, 4.0, and 3.5 mM, respectively. The ability of Dehalogenimonas spp. to carry out anaerobic reductive dechlorination even in the presence of high concentrations of chlorinated aliphatic alkanes has important implications for remediation of contaminated soil and groundwater. PMID:23046725

  19. Dehalogenimonas spp. can Reductively Dehalogenate High Concentrations of 1,2-Dichloroethane, 1,2-Dichloropropane, and 1,1,2-Trichloroethane.

    PubMed

    Maness, Andrew D; Bowman, Kimberly S; Yan, Jun; Rainey, Fred A; Moe, William M

    2012-01-01

    The contaminant concentrations over which type strains of the species Dehalogenimonas alkenigignens and Dehalogenimonas lykanthroporepellens were able to reductively dechlorinate 1,2-dichloroethane (1,2-DCA), 1,2-dichloropropane (1,2-DCP), and 1,1,2-trichloroethane (1,1,2-TCA) were evaluated. Although initially isolated from an environment with much lower halogenated solvent concentrations, D. alkenigignens IP3-3T was found to reductively dehalogenate chlorinated alkanes at concentrations comparable to D. lykanthroporepellens BL-DC-9T. Both species dechlorinated 1,2-DCA, 1,2-DCP, and 1,1,2-TCA present at initial concentrations at least as high as 8.7, 4.0, and 3.5 mM, respectively. The ability of Dehalogenimonas spp. to carry out anaerobic reductive dechlorination even in the presence of high concentrations of chlorinated aliphatic alkanes has important implications for remediation of contaminated soil and groundwater. PMID:23046725

  20. Novel Processing of 81-mm Cu Shaped Charge Liners

    SciTech Connect

    Schwartz, A; Korzekwa, D

    2002-01-16

    A seven-step procedure was developed for producing shaped charge liner blanks by back extrusion at liquid nitrogen temperatures. Starting with a 38.1-mm diameter, 101.6-mm long cylinder at 77K, three forging steps with a flat-top die are required to produce the solid cone while maintaining low temperature. The solid cone is forged in four individual back extrusions at 77K to produce the rough liner blank. This procedure is capable of being run in batch processes to improve the time efficiency.

  1. High voltage variable diameter insulator

    DOEpatents

    Vanecek, David L.; Pike, Chester D.

    1984-01-01

    A high voltage feedthrough assembly (10) having a tubular insulator (15) extending between the ground plane ring (16) and the high voltage ring (30). The insulator (15) is made of Pyrex and decreases in diameter from the ground plane ring (16) to the high voltage ring (30), producing equipotential lines almost perpendicular to the wall (27) of the insulator (15) to optimize the voltage-holding capability of the feedthrough assembly (10).

  2. Six-mm, plane-wave shock driver

    SciTech Connect

    Frank, A.M.; Chau, H.H.

    1993-06-14

    A 6-mm-diameter, plane-wave shock generation system has been developed and characterized as a laboratory bench driver for small scale experiments. The driver is based on an exploding-foil-driven slapper used either directly or to initiate an HE pellet. The slapper is driven by a low-inductance fireset with burst currents on the order of 30 kA and burst times of about 250ns, with a time-to-burst jitter under 10ns. Both the slapper impact and the detonation breakout of the pellet have been measured to be flat to within 10ns over a 6-mm diameter. Fabry-Perot velocimetry of impacts with LiF crystals were used to characterize shock pressures and durations. Attenuator plates and flyers driven by the HE were also measured, which provided a variety of available pulse shapes and data for modeling efforts.

  3. Fine Structure in the Mm-Wavelength Spectra of the Active Region

    NASA Astrophysics Data System (ADS)

    Sawant, H. S.; Cecatto, J. R.

    1990-11-01

    RESUMEN. Faltan observaciones solares espectrosc6picas en la longitud de onda milimetrica. Hay sugerencias de que se puede superponer una fi na estructura en frecuencia a la componente-S de la regi6n solar activa, asi como a la componente del brote en las longitudes de onda milimetri- cas. Se ha desarrollado un receptor de alta sensibilidad de pasos de frecuencia que opera en el intervalo de 23-18 GHz con una resoluci6n de 1 GHz y resoluci6n de tiempo variable entre 1.2 y 96 sec, usando la an- tena de Itapetinga de 13.7-m para estudiar la estructura fina en frecuencia y tiempo. Discutimos el espectro en longitud de onda-mm en re- giones activas y su evoluci6n en el tiempo. El estudio de Ia evoluci6n en el tiempo de la regi6n activa en AR 5569 observada el 29 de junio de 1989, sugiere la existencia de estructuras finas como funci6n deltiempo. ABSTRACT. There is a lack of mm-wavelength spectroscopic solar observations. There are suggestions that a fine structure in frequency may be superimposed on the S-component of solar active region as well as on the burst component at inm-wavelengths. To study fine structure in frequency and time, a high sensitivity step frequency receiver operating in the frequency range 23-18 GHz with frequency resolution of 1 GHz and variable time resolution 1.2 to 96 sec, using 13.7 m diameter Itapetinga radome covered antenna, has been developed. Here, we discuss mm-wavelength spectra of active regions and their time evolution. Study of time evolution of an active region AR 5569 observed on 29th June, 1989 suggests existence of fine structures as a function of time. ( Ck : SUN-ACTIVITY - SUN-RADIO RADIATION

  4. 7 CFR 51.2934 - Diameter.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Standards for Grades of Apricots Definitions § 51.2934 Diameter. Diameter means the greatest diameter, measured through the center of the apricot, at right angles to a line running from the stem to the...

  5. 7 CFR 51.2934 - Diameter.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Standards for Grades of Apricots Definitions § 51.2934 Diameter. Diameter means the greatest diameter, measured through the center of the apricot, at right angles to a line running from the stem to the...

  6. 7 CFR 51.2934 - Diameter.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apricots Definitions § 51.2934 Diameter. Diameter means the greatest diameter, measured through the center of the apricot, at right angles to a...

  7. 7 CFR 51.2934 - Diameter.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apricots Definitions § 51.2934 Diameter. Diameter means the greatest diameter, measured through the center of the apricot, at right angles to a...

  8. 7 CFR 51.2934 - Diameter.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... Standards for Grades of Apricots Definitions § 51.2934 Diameter. Diameter means the greatest diameter, measured through the center of the apricot, at right angles to a line running from the stem to the...

  9. Apollo 12 70 mm photographic catalog

    NASA Technical Reports Server (NTRS)

    1970-01-01

    Proof prints of the 70-mm photography are presented, sorted by magazine and frame number. The 28 lunar surface panorama mosaics and a listing of the mosaics are included. The catalog is designed to be used in conjunction with the "Apollo 12 Photography: 70-mm, 16-mm, and 35-mm Frame Index', which makes it possible to locate the area covered by each frame.

  10. Catalytic hydrodechlorination of 1,2-dichloroethane using copper nanoparticles under reduction conditions of sodium borohydride.

    PubMed

    Huang, Chang-Chieh; Lo, Shang-Lien; Tsai, Shin-Mu; Lien, Hsing-Lung

    2011-09-01

    1,2-Dichloroethane (1,2-DCA) is a raw material used for the manufacture of vinyl chloride monomer (VCM) and therefore has very often been detected in the groundwater nearby the VCM manufacturing plant. Zero-valent iron (ZVI) is capable of degrading a wide array of highly chlorinated contaminants; however, the reactivity of ZVI towards 1,2-DCA is very low. In this study, zero-valent copper nanoparticles have been synthesized for effective dechlorination of 1,2-DCA under reduction conditions of sodium borohydride. Copper nanoparticles consisted of mainly metallic copper (Cu(0)) with small amounts of cuprous oxide (Cu(2)O). They have surface areas of about 19.0 m(2) g(-1) and an average diameter of 15 nm. Batch experiments were conducted to test the effectiveness of copper nanoparticles for 1,2-DCA degradation using sodium borohydride as electron donors where the ORP was measured as -1100 mV. More than 80% of 1,2-DCA (30 mg L(-1)) was rapidly degraded within 2 h in the presence of both copper nanoparticles (2.5 g L(-1)) and borohydride (25 mM). No reduction of 1,2-DCA was observed when the system contained either copper nanoparticles alone or borohydride alone. The degradation intermediates included ethane and ethylene accounting for 79% and ∼1.5% of the 1,2-DCA lost, respectively. Potential environmental applications can be achieved by immobilizing copper nanoparticles onto the surface of reducing metals to form a reactive bimetallic structure. PMID:21850296

  11. Pupil diameter reflects uncertainty in attentional selection during visual search

    PubMed Central

    Geng, Joy J.; Blumenfeld, Zachary; Tyson, Terence L.; Minzenberg, Michael J.

    2015-01-01

    Pupil diameter has long been used as a metric of cognitive processing. However, recent advances suggest that the cognitive sources of change in pupil size may reflect LC-NE function and the calculation of unexpected uncertainty in decision processes (Aston-Jones and Cohen, 2005; Yu and Dayan, 2005). In the current experiments, we explored the role of uncertainty in attentional selection on task-evoked changes in pupil diameter during visual search. We found that task-evoked changes in pupil diameter were related to uncertainty during attentional selection as measured by reaction time (RT) and performance accuracy (Experiments 1-2). Control analyses demonstrated that the results are unlikely to be due to error monitoring or response uncertainty. Our results suggest that pupil diameter can be used as an implicit metric of uncertainty in ongoing attentional selection requiring effortful control processes. PMID:26300759

  12. Experimental study of star-like and small-diameter wire-array z-pinches on the 1-MA Zebra generator

    SciTech Connect

    Ivanov, V. V.; Sotnikov, V. I.; Kindel, J. M.; Hakel, P.; Mancini, R. C.; Astanovitskiy, A. L.; Haboub, A.; Altemara, S. D.; Le Galloudec, B.; Nalajala, V.; Shevelko, A. P.; Kazakov, E. D.

    2009-01-21

    Star-like wire arrays and small-diameter (1-3 mm in diameter) cylindrical loads were tested in the 1-MA Zebra generator. Mitigation of plasma inhomogeneity was observed in the implosions of star-like loads, which consisted of multiple nested, cylindrical arrays aligned azimuthally such that the wires appear as linear array 'rays' extending from the axis of symmetry. The implosion in these loads is directed along the 'rays' of the star and cascades from wire to wire to the center to form moving plasma columns with smooth leading edges. Despite the low azimuthal symmetry, a star-like wire array produces a stable x-ray pulse with a high peak power and a short duration of 8-12-ns. This can be linked to the stabilization of instabilities due to the multiple nesting. X-ray generation and implosion dynamics in wire arrays 1-16 mm in diameter were investigated to find a transition between the regime with prevailing kinetic energy and 'non-kinetic' plasma heating. Loads 3-8 mm in diameter generate the highest x-ray power at the Zebra generator. The fall of x-ray power in 1-2-mm loads can be linked to the lack of kinetic energy. Laser probing diagnostics show the formation of 'necks' on the pinch during the bubble-like implosion. The energy balance provides the evidence of the enhanced plasma heating in z-pinches. Features of the implosions in small-diameter wire-arrays can help to identify the mechanisms of energy dissipation.

  13. Design considerations and initial performance of a 1.2 cm{sup 2} beta imaging intra-operative probe

    SciTech Connect

    Tornai, M.P.; MacDonald, L.R.; Levin, C.S.; Siegel, S.; Hoffman, E.J.

    1996-08-01

    A novel small area beta ({beta}{sup {+-}}) detector is under development for nuclear emission imaging of surgically exposed, radiolabeled tumor beds. The imaging device front-end consists of a 0.5 mm thick by 1.25 cm diameter CaF{sub 2}(Eu) scintillator disk coupled to a rapid bundle of 2 mm diameter double clad optical fibers through a polystyrene light diffuser. The detector area (1.2 cm{sup 2}) was determined by the requirement of introducing the probe into small cavities, e.g. during neuro-surgical lesion resection, but large enough to produce images of clinical significance. Flexible back-end optical fibers (1.9 m long) were coupled to the front-end components allowing {approximately} 75 photoelectrons to e detected for mean beta energies of 250 keV, indicating that sufficient signal can be obtained with clinical beta emitters (e.g. {sup 18}F, {sup 131}I). The long flexible fibers guide the scintillation light to a Philips XP1700 series, fiber optical faceplate, Multi-Channel PMT. The parallel MC-PMT outputs re fed into a variable gain, charge divider network and an i-V pre-amplifier/line driver network, whose resulting four outputs are digitized and histogrammed with standard Anger positioning logic. The various components in the imaging chain were evaluated and optimized by both simulations and measurements. Line spread functions measured in the 10.8 mm FOV were 0.50 mm {+-} 0.038 mm and 0.55 mm {+-} 0.065 mm FWHM in X and Y, respectively. A 20% variation in pulse height and minimal variation in spatial resolution was observed. The differential image uniformity was measured to be {+-}15.6% with {approximately} 150 cts/pixel. Preliminary images show excellent reproduction of phantom activity distributions.

  14. Mm-size bistable zipping dielectric elastomer actuators for integrated microfluidics

    NASA Astrophysics Data System (ADS)

    Maffli, Luc; Rosset, Samuel; Shea, Herbert R.

    2013-04-01

    We report on a new structure of Dielectric Elastomer Actuators (DEAs) called zipping DEAs, which have a set of unique characteristics that are a good match for the requirements of electrically-powered integrated microfluidic pumping and/or valving units as well as Braille displays. The zipping DEAs operate by pulling electrostatically an elastomer membrane in contact with the rigid sidewalls of a sloped chamber. In this work, we report on fully functional mm-size zipping DEAs that demonstrate a complete sealing of the chamber sidewalls and a tunable bistable behavior, and compare the measurements with an analytical model. Compared to our first generation of devices, we are able vary the sidewall angle and benefit therefore from more flexibility to study the requirements to make fully functional actuators. In particular, we show that with Nusil CF19 as membrane material (1.2 MPa Young's modulus), it is possible to zip completely 2.3 mm diameter chambers with 15° and 21° sidewalls angle equibiaxially prestretched to λ0=1.12 and 15° chambers with λ0=1.27.

  15. Corneal biomechanical properties changes after coaxial 2.2-mm microincision and standard 3.0-mm phacoemulsification

    PubMed Central

    Zhang, Zhe; Yu, Hua; Dong, Hui; Wang, Li; Jia, Ya-Ding; Zhang, Su-Hua

    2016-01-01

    AIM To compare the changes in corneal biomechanics measured by ocular response analyzer (ORA) after 2.2-mm microincision cataract surgery and 3.0-mm standard coaxial phacoemulsification. METHODS The prospective nonrandomized study comprised eyes with cataract that had 2.2-mm coaxial microincision or 3.0-mm standard incision phacoemulsification. The corneal hysteresis (CH), corneal resistance factor (CRF), corneal-compensated intraocular pressure (IOPcc) and Goldmann-correlated intraocular pressure (IOPg) were measured by ORA preoperatively and at 1d, 1-, 2-, 3- and 4-week postoperatively. Results were analyzed and compared between groups. RESULTS In both groups, CH decreased in the immediate postoperative period (P<0.05), returned to the preoperative level at one week (P=0.249) in the 2.2-mm group, and at two weeks in the 3.0-mm group (P=0.264); there was no significant change in CRF values. In 2.2-mm group, mean IOPcc and IOPg increased at 1d postoperatively (both P<0.05), and returned to preoperative level at one week (P=0.491 and P=0.923, respectively). In 3.0-mm group, mean IOPcc and IOPg increased at 1d and 1wk postoperatively (P=0.005 and P=0.029, respectively), and returned to preoperative level at 2wk (P=0.347 and P=0.887, respectively). CONCLUSION Significant differences between preoperative and postoperative corneal biomechanical values were found for CH, IOPcc and IOPg. But the recovery time courses were different between the two groups. The 2.2-mm coaxial microincision cataract surgery group seemed recovery faster compared to the 3.0-mm standard coaxial phacoemulsification group. PMID:26949640

  16. Predicting Hamstring Graft Diameter Using MRI and Anthropometry

    PubMed Central

    Fritsch, Brett A; Mhaskar, Vikram A; An, Vincent Vinh Gia; Scholes, Corey

    2016-01-01

    Objectives: Graft diameter is one variable that may affect outcome of ACL reconstruction. The ability to predict the size of a graft in a given patient pre-operatively may help guide graft selection and preparation technique. Various papers have correlated anthropometric data and MRI tendon measurements to intraoperative graft diameter, although no papers have investigated these together. The intra-operative diameter of a hamstring autograft will be influenced by graft preparation technique. Our study aimed to investigate the prediction of intraoperative graft diameter of 2 different graft construct techniques (4-strand semitendinosus versus quadrupled semitendinosus) using anthropometry and MRI measurements. Methods: Retrospective review of two groups of ACL reconstruction using different graft preparation techniques was performed. “Conventional” 4-strand gracilis + semitendinosus with fixed suspension at the femur and screw fixation at the tibia were compared with quadrupled semitendinosus grafts with adjustable suspensory fixation at each end (Graftlink). Cross-sectional areas (XSA) of the semitendinosus and gracilis tendons was measured in the axial slice of a T2 weighted MRI image using a region-of-interest tool. Stepwise linear regression using intraoperative graft diameter as the dependant variable was performed using MRI XSA of the semitendinosus and gracilis tendons, gender and height as predictors. Results: 129 ACL Reconstruction in 127 patients were done in the time period, 89 of which were done conventionally, and 40 which employed the Graftlink construct. The median graft diameter in the Graftlink group (8.5mm IQR8-9) was greater than that of the conventional group (8mm, IQR 7.5-8) (p < 0.001). MRI XSA of semitendinosus and height were statistically significant predictors of diameter in the Graftlink group (R2 = 51%), whilst MRI XSA of semitendinosus + gracilis and gender were predictors in the conventional group (R2 = 36%). Conclusion: Graftlink

  17. Fatigue acceptance test limit criteria for larger diameter rolled thread fasteners

    SciTech Connect

    Kephart, A.R.

    1999-05-19

    This document describes a fatigue lifetime acceptance test criterion by which studs having rolled threads, larger than 1.0 inches (25 mm) in diameter, can be assured to meet minimum quality attributes associated with a controlled rolling process.

  18. Minimum tube diameters for steady propagation of gaseous detonations

    NASA Astrophysics Data System (ADS)

    Gao, Y.; Ng, H. D.; Lee, J. H. S.

    2014-07-01

    Recent experimental results on detonation limits are reported in this paper. A parametric study was carried out to determine the minimum tube diameters for steady detonation propagation in five different hydrocarbon fuel-oxygen combustible mixtures and in five polycarbonate test tube diameters ranging from 50.8 mm down to a small scale of 1.5 mm. The wave propagation in the tube was monitored by optical fibers. By decreasing the initial pressure, hence the sensitivity of the mixture, the onset of limits is indicated by an abrupt drop in the steady detonation velocity after a short distance of travel. From the measured wave velocities inside the test tube, the critical pressure corresponding to the limit and the minimum tube diameters for the propagation of the detonation can be obtained. The present experimental results are in good agreement with previous studies and show that the measured minimum tube diameters can be reasonably estimated on the basis of the /3 rule over a wide range of conditions, where is the detonation cell size. These new data shall be useful for safety assessment in process industries and in developing and validating models for detonation limits.

  19. Development and evaluation of elastomeric hollow fiber membranes as small diameter vascular graft substitutes.

    PubMed

    Mercado-Pagán, Ángel E; Kang, Yunqing; Findlay, Michael W; Yang, Yunzhi

    2015-04-01

    Engineering of small diameter (<6mm) vascular grafts (SDVGs) for clinical use remains a significant challenge. Here, elastomeric polyester urethane (PEU)-based hollow fiber membranes (HFMs) are presented as an SDVG candidate to target the limitations of current technologies and improve tissue engineering designs. HFMs are fabricated by a simple phase inversion method. HFM dimensions are tailored through adjustments to fabrication parameters. The walls of HFMs are highly porous. The HFMs are very elastic, with moduli ranging from 1-4MPa, strengths from 1-5MPa, and max strains from 300-500%. Permeability of the HFMs varies from 0.5-3.5×10(-6)cm/s, while burst pressure varies from 25 to 35psi. The suture retention forces of HFMs are in the range of 0.8 to 1.2N. These properties match those of blood vessels. A slow degradation profile is observed for all HFMs, with 71 to 78% of the original mass remaining after 8weeks, providing a suitable profile for potential cellular incorporation and tissue replacement. Both human endothelial cells and human mesenchymal stem cells proliferate well in the presence of HFMs up to 7days. These results demonstrate a promising customizable PEU HFMs for small diameter vascular repair and tissue engineering applications. PMID:25686982

  20. Development and evaluation of elastomeric hollow fiber membranes as small diameter vascular graft substitutes

    PubMed Central

    Mercado-Pagán, Ángel E.; Kang, Yunqing; Findlay, Michael W.; Yang, Yunzhi

    2015-01-01

    Engineering of small diameter (<6 mm) vascular grafts (SDVGs) for clinical use, remains a significant challenge. Here, elastomeric polyester urethane (PEU)-based hollow fiber membranes (HFM) are presented as an SDVG candidate to target the limitations of current technologies and improve tissue engineering designs. HFMs are fabricated by a simple phase inversion method. HFM dimensions are tailored through adjustments to fabrication parameters. The walls of HFMs are highly porous. The HFMs are very elastic, with moduli ranging from 1–4 MPa, strengths from 1–5 MPa, and max strains from 300–500%. Permeability of the HFMs varies from 0.5–3.5×10−6 cm/s, while burst pressure varies from 25 to 35 psi. The suture retention forces of HFMs are in the range of 0.8 to 1.2 N. These properties match those of blood vessels. A slow degradation profile is observed for all HFMs, with 71 to 78% of the original mass remaining after 8 weeks, providing a suitable profile for potential cellular incorporation and tissue replacement. Both human endothelial cells and human mesenchymal stem cells proliferate well in the presence of HFMs up to 7 days. These results demonstrate a promising customizable PEU HFMs for small diameter vascular repair and tissue engineering applications. PMID:25686982

  1. 7 CFR 51.2656 - Diameter.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Standards for Grades for Sweet Cherries 1 Definitions § 51.2656 Diameter. Diameter means the greatest dimension measured at right angles to a line from the stem to the blossom end of the cherry....

  2. Ultrasonographic Measurement of Normal Common Bile Duct Diameter and its Correlation with Age, Sex and Anthropometry

    PubMed Central

    Mehra, Simmi; Lal, Vivek

    2014-01-01

    Background: Ultrasonography is the diagnostic method of choice for visualization and rational work-up of abdominal organs. The dilatation of the common bile duct helps distinguish obstructive from non-obstructive causes of jaundice. Availability of normal measurements of the common bile duct is therefore important. There exists significant variations in the anthropometric features of various populations, regions and races. Aim: Study was conducted to obtain data on sonographically measured diameters of common bile duct in a series of normal Rajasthani population and to measure its correlation with age, sex and anthropometry. Setting and Design: Cross-sectional hospital-based study conducted at Mahatma Gandhi Medical College and Hospital, Jaipur, India. Materials and Methods: Study included 200 participants with equal proportion belonging to either sex. Common bile duct was measured at three locations- at the porta hepatis, in the most distal aspect of head of pancreas and mid-way between these points. Anthropometric measurements including height, weight, chest circumference, circumference at transpyloric plane, circumference at umbilicus and circumference at hip were obtained using standard procedures. Statistical Analysis: Univariable analysis with measures of frequency and standard deviation and bivariable analysis using correlation. Results: Mean age of study subjects was 34.5 years (Range 18-85 years). Mean diameters of the common bile duct in the three locations were: proximal, 4.0 mm (SD 1.02 mm); middle, 4.1 mm (SD 1.01 mm); and distal, 4.2 mm (SD 1.01 mm) and overall mean for all measures 4.1 mm (SD 1.01 mm). Average diameter ranged from 2.0 mm to 7.9 mm, with 95 percent of the subjects having a diameter of less than 6 mm. We observed a statistically significant relation of common bile duct with age, along with a linear trend. There was no statistically significant difference in common bile duct diameter between male and female subjects. The diameter did

  3. Augmented PMMA distribution: improvement of mechanical property and reduction of leakage rate of a fenestrated pedicle screw with diameter-tapered perforations.

    PubMed

    Tan, Quan-Chang; Wu, Jian-Wei; Peng, Fei; Zang, Yuan; Li, Yang; Zhao, Xiong; Lei, Wei; Wu, Zi-Xiang

    2016-06-01

    OBJECTIVE This study investigated the optimum injection volume of polymethylmethacrylate (PMMA) to augment a novel fenestrated pedicle screw (FPS) with diameter-tapered perforations in the osteoporotic vertebral body, and how the distribution characteristics of PMMA affect the biomechanical performance of this screw. METHODS Two types of FPSs were designed (FPS-A, composed of 6 perforations with an equal diameter of 1.2 mm; and FPS-B, composed of 6 perforations each with a tapered diameter of 1.5 mm, 1.2 mm, and 0.9 mm from tip to head. Each of 28 human cadaveric osteoporotic vertebrae were randomly assigned to 1 of 7 groups: FPS-A1.0: FPS-A+1.0 ml PMMA; FPS-A1.5: FPS-A+1.5 ml PMMA; FPS-A2.0: FPS-A+2.0 ml PMMA; FPS-B1.0: FPS-B+1.0 ml PMMA; FPS-B1.5: FPS-B+1.5 ml PMMA; FPS-B2.0: FPS-B+2.0 ml PMMA; and conventional pedicle screws (CPSs) without PMMA. After the augmentation, 3D CT was performed to assess the cement distribution characteristics and the cement leakage rate. Axial pullout tests were performed to compare the maximum pullout force thereafter. RESULTS The CT construction images showed that PMMA bone cement formed a conical mass around FPS-A and a cylindrical mass around FPS-B. When the injection volume was increased from 1.0 ml to 2.0 ml, the distribution region of the PMMA cement was enlarged, the PMMA was distributed more posteriorly, and the risk of leakage was increased. When the injection volume reached 2.0 ml, the risk of cement leakage was lower for screws having diameter-tapered perforations. The pullout strengths of the augmented FPS-A groups and FPS-B groups were higher than that of the CPS group (p < 0.0001). All FPS-B groups had a higher pullout strength than the FPS-A groups. CONCLUSIONS The diameter of the perforations affects the distribution of PMMA cement. The diameter-tapered design enabled PMMA to form larger bone-PMMA interfaces and achieve a relatively higher pullout strength, although statistical significance was not reached. Study

  4. A 10-mm MR-Conditional Unidirectional Pneumatic Stepper Motor.

    PubMed

    Chen, Yue; Mershon, Christopher D; Tse, Zion Tsz Ho

    2015-04-01

    Magnetic resonance (MR) conditional robotic devices facilitate accurate interventional procedures under MR imaging (MRI) guidance. For this purpose, a compact (10-mm diameter) MR-conditional stepper motor is presented. The device features seven key components, which contribute to a dense and easy to fabricate design. Alternating bursts of pressurized air and vacuum can drive the motor in 60° per step to achieve a maximum torque of 2.4 mNm. The relationship between torque and angular speed was investigated to demonstrate motor performance under different loading conditions. The stepper motor was tested in a GE 3T MRI scanner to verify its MR-compatibility. A maximum artifact width of 3 mm was measured in MRI images and a maximum signal-to-noise ratio reduction of 2.49% was recorded. PMID:25419104

  5. A 10-mm MR-Conditional Unidirectional Pneumatic Stepper Motor

    PubMed Central

    Chen, Yue; Mershon, Christopher D.; Tse, Zion Tsz Ho

    2014-01-01

    Magnetic resonance (MR) conditional robotic devices facilitate accurate interventional procedures under MR imaging (MRI) guidance. For this purpose, a compact (10-mm diameter) MR-conditional stepper motor is presented. The device features seven key components, which contribute to a dense and easy to fabricate design. Alternating bursts of pressurized air and vacuum can drive the motor in 60° per step to achieve a maximum torque of 2.4 mNm. The relationship between torque and angular speed was investigated to demonstrate motor performance under different loading conditions. The stepper motor was tested in a GE 3T MRI scanner to verify its MR-compatibility. A maximum artifact width of 3 mm was measured in MRI images and a maximum signal-to-noise ratio reduction of 2.49% was recorded. PMID:25419104

  6. Application of MM wave therapy in radiology

    SciTech Connect

    Avakian, R.S.; Gasparyan, L.V.

    1995-12-31

    The authors studied the effects of MM wave electromagnetic radiation influence on patients, affected by X-ray radiation during the reparation works after Chernobyl nuclear power plant exposure. They compared results of treatment of two groups of patients: (1) control group patients received only basis therapy; (2) testing group, 10 patients received basis therapy and MM wave influence. The authors used the wide band noise generator `Artsakh - 2` for local irradiation on the acupuncture points. Their data proved that low intensity MM waves have immunocorrective, antioxidant effects, and MM wave therapy is a perspective method for treatment of patients with radiological pathology.

  7. Large Diameter, Radiative Extinction Experiments with Decane Droplets in Microgravity

    NASA Technical Reports Server (NTRS)

    Easton, John; Tien, James; Dietrich, Daniel

    1999-01-01

    The extinction of a diffusion flame is of fundamental interest in combustion science. Linan, Law, and Chung and Law analytically and experimentally determined an extinction boundary in terms of droplet diameter and pressure for a single droplet due to Damkohler, or blowoff, extinction. More recently, other researchers demonstrated extinction due to finite rate kinetics in reduced gravity for free droplets of heptane. Chao modeled the effect of radiative heat loss on a quasi-steady spherically symmetric single droplet burning in the absence of buoyancy. They determined that for increasing droplet diameter, a second limit can be reached such that combustion is no longer possible. This second, larger droplet diameter limit arises due to radiative heat loss, which increases with increasing droplet and flame diameter. This increase in radiative heat loss arises due to an increase in the surface area of the flame. Recently, Marchese modeled fuel droplets with detailed chemistry and radiative effects, and compared the results to other work. The modeling also showed the importance of radiative loss and radiative extinction Experiments examined the behavior of a large droplet of decane burning in reduced gravity onboard the NASA Lewis DC-9 aircraft, but did not show a radiative extinction boundary due to g-jitter (Variations in gravitational level and direction) effects. Dietrich conducted experiments in the reduced gravity environment of the Space Shuttle. This work showed that the extinction diameter of methanol droplets increased when the initial diameter of the droplets was large (in this case, approximately 5 mm). Theoretical results agreed with these experimental results only when the theory included radiative effects . Radiative extinction was experimentally verified by Nayagam in a later Shuttle mission. The following work focuses on the combustion and extinction of a single fuel droplet. The goal is to experimentally determine a large droplet diameter limit that

  8. Common bile duct diameter in an asymptomatic population: A magnetic resonance imaging study

    PubMed Central

    Peng, Rong; Zhang, Ling; Zhang, Xiao-Ming; Chen, Tian-Wu; Yang, Lin; Huang, Xiao-Hua; Zhang, Ze-Ming

    2015-01-01

    AIM: To measure the common bile duct (CBD) diameter by magnetic resonance cholangiopancreatography (MRCP) in a large asymptomatic population and analyze its some affecting factors. METHODS: This study included 862 asymptomatic subjects who underwent MRCP. The CBD diameter was measured at its widest visible portion on regular end-expiration MRCP for all subjects. Among these 862 subjects, 221 volunteers also underwent end-inspiration MRCP to study the effect of respiration on the CBD diameter. The age, sex, respiration, body length, body weight, body mass index (BMI), portal vein diameter (PVD), length of the extrahepatic duct and CBD, cystic junction radial orientation and location were recorded. The subjects were divided into 7 groups according to age. All of the above factors were compared with the CBD diameter on end-expiration MRCP. RESULTS: Among the 862 subjects, the CBD diameter was 4.13 ± 1.11 mm (range, 1.76-9.45 mm) and was correlated with age (r = 0.484; P < 0.05), with a dilation of 0.033 mm per year. The upper limit of the 95% reference range was 5.95 mm, resulting in a reasonable upper limit of 6 mm for the asymptomatic population. Respiration and other factors, including sex, body length, body weight, BMI, PVD, length of the extrahepatic duct and CBD, cystic junction radial orientation and location, were not related to the CBD diameter. CONCLUSION: We established a reference range for the CBD diameter on MRCP for an asymptomatic population. The CBD diameter is correlated with age. Respiration did not affect the non-dilated CBD diameter. PMID:26753065

  9. Production of a large-diameter uniform plasma by electron cyclotron resonance heating with a small-diameter Lisitano coil

    NASA Astrophysics Data System (ADS)

    Komori, A.; Takada, Y.; Yonesu, A.; Kawai, Y.

    1991-02-01

    A large-diameter uniform plasma is produced by electron cyclotron resonance heating with a slotted Lisitano coil of 9 cm in diameter by locating the resonance apart from the Lisitano coil. Although the plasma production with a Lisitano coil has been performed extensively by placing the resonance near the Lisitano coil, the influence of the resonance location has not received as much attention. When the resonance is located further than 8 cm from the Lisitano coil, the uniform plasma of ˜40 cm in diameter at densities of ˜1.2×1011 cm-3 is produced over the vacuum chamber with an inner radius of 46 cm. The microwave is propagated in the whole space between the resonance and the Lisitano coil, and spatial electric-field distributions of the microwave play an important role on forming the radially uniform plasma.

  10. MWD tool for deep, small diameter boreholes

    SciTech Connect

    Buytaert, J.P.R.; Duckworth, A.

    1992-03-17

    This patent describes an apparatus for measuring a drilling parameters while drilling a borehole in an earth formation, wherein the borehole includes a small diameter deep borehole portion and a large diameter upper borehole portion. It includes small diameter drillstring means for drilling the deep borehole portion; sensor means, disposed within the small diameter drillstring means, for measuring a drilling parameter characteristic of the deep portion of the borehole while drilling the deep portion of the borehole and for providing sensor output signals indicative of the measured parameter; an upper drillstring portion extending between the surface of the formation and the small diameter drillstring means, the upper drillstring portion including a large diameter drillstring portion; data transmission means disposed within the large diameter drillstring portion and responsive to the sensor output.

  11. A mediated polyphenol oxidase biosensor immobilized by electropolymerization of 1,2-diamino benzene.

    PubMed

    Akyilmaz, Erol; Kozgus, Ozge; Türkmen, Hayati; Cetinkaya, Bekir

    2010-06-01

    A biosensor based on a partially purified polyphenol oxidase (PPO) enzyme was developed by using electropolymerization of [(2,2'-bipyridine)(chloro)(p-cymene)rutenium(II)]chloride] mediator complex and 1,2-diamino benzene (DAB) on a screen printing Pt electrode (1mm diameter). The electropolymerization was carried out at +0.7V for 45min in phosphate buffer (50mM, pH 7.0) which contained 14.0U/10mL polyphenole oxidase, 200mM DAB and 2.5mM Ru-mediator complex solutions. Measurement is based on the detection of the oxidation current of the Ru-mediator complex that related to the enzymatic reaction catalyzed by PPO at +0.65V. The phosphate buffer (50mM, pH 7.0 containing 0.1M KCl) and 30 degrees C were established as being the optimum working conditions. Under the optimum experimental conditions a linear calibration curve was obtained between 5 and 100microM catechol concentration. The detection limit of the biosensor is 2.385microM. In the characterization studies of the biosensor some parameters such as effect of Ru-mediator types on the biosensor response, substrate specificity, reproducibility and storage stability were studied. From the experiments, the average value (x), standard deviation (SD) and coefficient of variation (CV%) were found to be 48.75microM,+/-1.56microM, and 3.2% respectively for 50microM catechol standard. PMID:19783226

  12. Prediction of quadruple hamstring graft diameter for anterior cruciate ligament reconstruction by anthropometric measurements

    PubMed Central

    Asif, Naiyer; Ranjan, Rahul; Ahmed, Sohail; Sabir, Aamir B; Jilani, Latif Z; Qureshi, Owais A

    2016-01-01

    Background: The literature is scanty regarding the anthropometric predictors on the diameter of quadruple hamstring graft obtained in anterior cruciate ligament (ACL) reconstruction in Indian population. Minimum diameter of the graft for ACL reconstruction should be >7 mm to preclude failure. The objective of this study was to assess the prediction of the hamstring graft diameter by several anthropometric parameters including age, thigh circumference, weight, height and body mass index (BMI). Materials and Methods: 46 consecutive patients who had undergone ACL reconstruction by the same surgeon using quadruple hamstring grafts were evaluated. The age, thigh circumference of the normal side, height, weight and BMI were recorded preoperatively and Pearson correlation was done using these parameters with graft diameter measured intraoperatively. Regression analysis in a stepwise manner was undertaken to assess the influence of individual anthropometric parameters on the graft diameter. Results: There were 44 males and 2 females. Mean age was 29.4 years, mean height was 172.6 cm, mean weight was 70.9 kg, mean BMI was 23.8 kg/m2, mean thigh circumference was 47.1 cm and mean graft diameter was 7.9 mm. There was a positive correlation individually between the thigh circumference and graft diameter obtained (r = 0.8, P < 0.01, n = 46), and between the height and graft diameter (r = 0.8, P < 0.01, n = 46). On the regression analysis thigh circumference and height were found to be significant predictors of graft diameter giving the following equation: Graft diameter (mm) = 0. 079 height (cm) +0.068 thigh circumference (cm) −9.031. Conclusion: Preoperatively using the above equation if graft diameter came out to be <7 mm then alternate options of graft material must be kept in mind in order to prevent failure. PMID:26955176

  13. Maxadilan, the Lutzomyia longipalpis vasodilator, drives plasma leakage via PAC1-CXCR1/2-pathway.

    PubMed

    Svensjö, Erik; Saraiva, Elvira M; Amendola, Rafael Silveira; Barja-Fidalgo, Christina; Bozza, Marcelo T; Lerner, Ethan A; Teixeira, Mauro M; Scharfstein, Julio

    2012-03-01

    Experiments were designed to determine if the vasodilatory peptides maxadilan and pituitary adenylate cyclase-activating peptide (PACAP-38) may cause plasma leakage through activation of leukocytes and to what extent these effects could be due to PAC1 and CXCR1/2 receptor stimulation. Intravital microscopy of hamster cheek pouches utilizing FITC-dextran and rhodamine, respectively, as plasma and leukocyte markers was used to measure arteriolar diameter, plasma leakage and leukocyte accumulation in a selected area (5mm(2)) representative of the hamster cheek pouch microcirculation. Our studies showed that the sand fly vasodilator maxadilan and PACAP-38 induced arteriolar dilation, leukocyte accumulation and plasma leakage in postcapillary venules. The recombinant mutant of maxadilan M65 and an antagonist of CXCR1/2 receptors, reparixin, and an inhibitor of CD11b/CD18 up-regulation, ropivacaine, inhibited all these effects as induced by maxadilan. Dextran sulfate, a complement inhibitor with heparin-like anti-inflammatory effects, inhibited plasma leakage and leukocyte accumulation but not arteriolar dilation as induced by maxadilan and PACAP-38. In vitro studies with isolated human neutrophils showed that maxadilan is a potent stimulator of neutrophil migration comparable with fMLP and leukotriene B(4) and that M65 and reparixin inhibited such migration. The data suggest that leukocyte accumulation and plasma leakage induced by maxadilan involves a mechanism related to PAC1- and CXCR1/2-receptors on leukocytes and endothelial cells. PMID:22036674

  14. Three-dimensional finite element analysis of stress distribution in composite resin cores with fiber posts of varying diameters.

    PubMed

    Okamoto, Kazuhiko; Ino, Teruno; Iwase, Naoki; Shimizu, Eitaroh; Suzuki, Megumi; Satoh, Goh; Ohkawa, Shuji; Fujisawa, Masanori

    2008-01-01

    Using three-dimensional finite element analysis (3D-FEA), stress distributions in the remaining radicular tooth structure were investigated under the condition of varying diameters of fiber post for fiber post-reinforced composite resin cores (fiber post and core) in maxillary central incisors. Four 3D-FEA models were constructed: (1) fiber post (ø1.2, ø1.4, and ø1.6 mm) and composite resin core; and (2) gold-cast post and core. Maximum stresses in the tooth structure for fiber post and core were higher than that for gold-cast post and core. In the former models, stresses in the tooth structure as well as in the composite resin were slightly reduced with increase in fiber post diameter. These results thus suggested that to reduce stress in the remaining radicular tooth with a large coronal defect, it is recommended to accompany a composite resin core with a fiber post of a large diameter. PMID:18309611

  15. 77 FR 59374 - Certain Small Diameter Carbon and Alloy Seamless Standard, Line and Pressure Pipe (Under 41/2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-27

    ... standard, line and pressure pipe (under 4\\1/2\\ inches) (hereinafter, ``small diameter pipe'') from Japan... Ltd. (``CNRL), a Canadian exporter of small diameter pipe, which had requested an administrative... International Trade Administration Certain Small Diameter Carbon and Alloy Seamless Standard, Line and...

  16. Multimedia contents production system (MM-CPS)

    NASA Astrophysics Data System (ADS)

    Roser, Miguel; Villegas, Paulo; Simon, Maria; Hernandez-Gil, J. F.; Aguado, Isidro

    1996-01-01

    A present characterized by deep worldwide changes, and a future where social relations and behaviors are going to undergo a substantial change need new telecommunications services in order to allow people to get closer, facilitate their daily tasks and place at their disposal multimedia information to be accessed anywhere and at any time. These new services are very dependent on the contents to be included in the applications. The purpose of this paper is to describe an universal MM contents production system (MM-CPS), which allows the generation of coded data files suitable to be included in MM-servers.

  17. Transport IV characterisation of MgB2 conductor at a bend radius of 50mm

    NASA Astrophysics Data System (ADS)

    Young, E. A.; Falorio, I.; Beduz, C.; Bailey, W. O. S.; Yang, Y.

    2014-05-01

    Performance of state of the art MgB2 multifilamentary conductor at a required bend radius is essential for many applications including but not limited to magnets and motors. The characterisation is generally done with benchmark transport Ic but further detail can be seen in IV characteristics which are undertaken in this paper. Two conductors with the same architecture but different diameters, 0.89 and 0.45 mm were measured from 32 K to 20 K in self-field in conditions of as received and deformed to a 50 mm bend diameter, corresponding to strains of 1.4 % and 0.7 % respectively. The qualifying 0.45mm conductor was further measured in background fields up to 3 T. The smaller diameter wire was found to have no signs of degradation of critical behaviour in Ic or IV characteristics.

  18. Large-Area Reflective Infrared Filters for Millimeter/Sub-mm Telescopes

    NASA Astrophysics Data System (ADS)

    Ahmed, Z.; Grayson, J. A.; Thompson, K. L.; Kuo, C.-L.; Brooks, G.; Pothoven, T.

    2014-09-01

    Ground-based millimeter and sub-millimeter telescopes are attempting to image the sky with ever-larger cryogenically-cooled bolometer arrays, but face challenges in mitigating the infrared loading accompanying large apertures. Absorptive infrared filters supported by mechanical coolers scale insufficiently with aperture size. Reflective metal-mesh filters placed behind the telescope window provide a scalable solution in principle, but have been limited by photolithography constraints to diameters under 300 mm. We present laser etching as an alternate technique to photolithography for fabrication of large-area reflective filters, and show results from lab tests of 500-mm-diameter filters. Filters with up to 700-mm diameter can be fabricated using laser etching with existing capability.

  19. Diagnostic value of the optic nerve sheath diameter in pseudotumor cerebri.

    PubMed

    Bekerman, Inessa; Sigal, Tal; Kimiagar, Itzhak; Almer, Zina Evy; Vaiman, Michael

    2016-08-01

    If persistent severe headache remains the only complaint of a patient, then the diagnosis of pseudotumor cerebri (PTC) can be delayed because in such cases practitioners are hesitant to immediately apply invasive intracranial pressure (ICP) measurement. Our purpose was to apply the technique of measuring diameters of the optic nerve sheath (ONSD) as a diagnostic tool in cases of PTC. Our aim was to provide practitioners with an additional sign to speed up their decision making about implementation of the lumbar puncture. In a retrospective study, CT scan data of 35 consecutive adult patients with PTC were collected and analyzed. ONSD were measured at the point where the ophthalmic artery crosses the optic nerve (anatomical landmark). The correlation analysis was performed with sex, age, and neuro-ophthalmological findings. We found that the ONSD was enlarged in 94.3% of patients with PTC. The enlarged ONSD were 6.2±1.2mm for the right and 6.3±0.9mm for the left (cut-off value >5.5mm). The enlargement was bilateral, and no correlation with age or sex was found (p=0.67 and p=0.76, respectively). Presence of papilledema was detected in 91.4% of patients (32/35) presenting as a slightly less valuable diagnostic sign compared with ONSD. We conclude that in the majority of cases of PTC the ONSD is significantly enlarged, indicating elevated ICP even if CT scans are negative. Implementing this ONSD method as a diagnostic tool in cases of suspected PTC may help in early accurate diagnosis, avoiding misdiagnosis, and providing appropriate early treatment. PMID:27168453

  20. Numerical Study to Obtain the Improved Field Homogeneity and Enlarged Inner Diameter of HTS Bulk Magnet for Compact NMR

    NASA Astrophysics Data System (ADS)

    Miyazawa, D.; Kim, S. B.; Kitamura, H.; Ishizuka, D.; Hojo, K.

    We have been studying the compact magnet for NMR device that consists of a stacked high temperature superconducting (HTS) GdBCO bulk annuli. We can generate the trapped magnetic field over 1.5 T at 77.4 K and 150 ppm/cm3 on inner diameter of 20 mm HTS bulks using field compensation methods. However, it is necessary to enlarge the inner diameter of the HTS bulk magnet because the diameter of commercial NMR probe is larger than 20 mm. In this paper, we studied an optimal shape of the stacked HTS bulk magnet to obtain the enlarged inner diameter using 3-D FEM based analysis. We was able to enlarge the inner diameter of the HTS bulk magnet from 20 mm to 34 mm remaining magnetic field strength of 1.5 T and magnetic field homogeneity of 666 ppm/cm3 by proposed passive field compensation method.

  1. MM Algorithms for Geometric and Signomial Programming.

    PubMed

    Lange, Kenneth; Zhou, Hua

    2014-02-01

    This paper derives new algorithms for signomial programming, a generalization of geometric programming. The algorithms are based on a generic principle for optimization called the MM algorithm. In this setting, one can apply the geometric-arithmetic mean inequality and a supporting hyperplane inequality to create a surrogate function with parameters separated. Thus, unconstrained signomial programming reduces to a sequence of one-dimensional minimization problems. Simple examples demonstrate that the MM algorithm derived can converge to a boundary point or to one point of a continuum of minimum points. Conditions under which the minimum point is unique or occurs in the interior of parameter space are proved for geometric programming. Convergence to an interior point occurs at a linear rate. Finally, the MM framework easily accommodates equality and inequality constraints of signomial type. For the most important special case, constrained quadratic programming, the MM algorithm involves very simple updates. PMID:24634545

  2. MM Algorithms for Geometric and Signomial Programming

    PubMed Central

    Lange, Kenneth; Zhou, Hua

    2013-01-01

    This paper derives new algorithms for signomial programming, a generalization of geometric programming. The algorithms are based on a generic principle for optimization called the MM algorithm. In this setting, one can apply the geometric-arithmetic mean inequality and a supporting hyperplane inequality to create a surrogate function with parameters separated. Thus, unconstrained signomial programming reduces to a sequence of one-dimensional minimization problems. Simple examples demonstrate that the MM algorithm derived can converge to a boundary point or to one point of a continuum of minimum points. Conditions under which the minimum point is unique or occurs in the interior of parameter space are proved for geometric programming. Convergence to an interior point occurs at a linear rate. Finally, the MM framework easily accommodates equality and inequality constraints of signomial type. For the most important special case, constrained quadratic programming, the MM algorithm involves very simple updates. PMID:24634545

  3. QM/MM Calculations on Proteins.

    PubMed

    Ryde, U

    2016-01-01

    In this chapter, I discuss combined quantum mechanics (QM) and molecular mechanics (MM; QM/MM) calculations for proteins. In QM/MM, a small but interesting part of the protein is treated by accurate QM methods, whereas the remainder is treated by faster MM methods. The prime problems with QM/MM calculations are bonds between the QM and MM systems, the selection of the QM system, and the local-minima problem. The two first problems can be solved by the big-QM approach, including in the QM calculation all groups within 4.5-6Å of the active site and all buried charges in the protein. The third problem can be solved by calculating free energies. It is important to study QM/MM energy components to ensure that the results are stable and reliable. They can also be used to understand the reaction and the effect of the surroundings, eg, by dividing the catalytic effect into bonded, van der Waals, electrostatic, and geometric components and to deduce which parts of the protein contribute most to the catalysis. It should be ensured that the QM calculations are reliable and converged by extending the basis set to quadruple-zeta quality, including a proper treatment of dispersion, as well as years experience and method development calculations with both pure and hybrid density functional theory methods. If the latter give differing results, calibration with high-level QM methods is needed. Reactions that change the net charge should be avoided. QM/MM calculations can be combined with experimental methods. PMID:27498637

  4. High Rate Proton Irradiation of 15mm Muon Drifttubes

    NASA Astrophysics Data System (ADS)

    Zibell, A.; Biebel, O.; Hertenberger, R.; Ruschke, A.; Schmitt, Ch.; Kroha, H.; Bittner, B.; Schwegler, P.; Dubbert, J.; Ott, S.

    2012-08-01

    Future LHC luminosity upgrades will significantly increase the amount of background hits from photons, neutrons 11.11d protons in the detectors of the ATLAS muon spectrometer. At the proposed LHC peak luminosity of 5\\cdot 1034(1)/(cm2s), background hit rates of more than 10(kHz)/(cm2) are expected in the innermost forward region, leading to a loss of performance of the current tracking chambers. Based on the ATLAS Monitored Drift Tube chambers, a new high rate capable drift tube detecor using tubes with a reduced diameter of 15mm was developed. To test the response to highly ionizing particles, a prototype chamber of 46 15mm drift tubes was irradiated with a 20 MeV proton beam at the tandem accelerator at the Maier-Leibnitz Laboratory, Munich. Three tubes in a planar layer were irradiated while all other tubes were used for reconstruction of cosmic muon tracks through irradiated and nonirradiated parts of the chamber. To determine the rate capability of the 15mm drifttubes we investigated the effect of the proton hit rate on pulse height, efficiency and spatial resolution of the cosmic muon signals.

  5. Stress Analysis on Single Cobalt/Chrome Prosthesis With a 15-mm Cantilever Placed Over 10/13/15-mm-length Implants: A Simulated Photoelastic Model Study.

    PubMed

    Gastaldo, José Fábio Guastelli; Pimentel, Angélica Castro; Gomes, Maria Helena; Sendyk, Wilson Roberto; Laganá, Dalva Cruz

    2015-12-01

    The aim of study was to assess the stress around 10/13/15-mm implants in the mandibular area with a 15-mm cantilevered acrylic-resin-coated prostheses following the application force, using the photoelasticity method. Three photoelastic mandibular models were created containing 10-, 13-, and 15-mm implants in length and 3.75 mm in diameter. The implants had bore internal hex connections and were placed parallel to the intermental region. Abutments with 1-mm high cuffs were placed over the implants, and a single cobalt/chrome metallic prosthesis with a 15-mm cantilever, coated with thermoplastic acrylic resin, was placed on top. Loads of 1.0 and 3.0 bars were applied, and the images were photographed and assessed by photoelasticity method. The greatest stress levels were observed for the 10-mm implants. The stress pattern was the same regardless of implant length; only the magnitude of the stress along the implant body revealed changes. Increased implant length played a role in reducing stress on the investigated area of the model, and the 15-mm implants exhibited the best performance in regard to stress distribution. The highest stress levels were found in the implants closest to the cantilever and the central implant. The longest implants were more favorable in regard to the stress distribution on the peri-implant support structures in the 15-mm cantilevered prosthesis under loads. PMID:24914673

  6. Serial Measurements of Splanchnic Vein Diameters in Rats Using High-Frequency Ultrasound

    PubMed Central

    Seitz, Bridget M.; Krieger-Burke, Teresa; Fink, Gregory D.; Watts, Stephanie W.

    2016-01-01

    The purpose of this study was to investigate serial ultrasound imaging in rats as a fully non-invasive method to (1) quantify the diameters of splanchnic veins in real time as an indirect surrogate for the capacitance function of those veins, and (2) assess the effects of drugs on venous dimensions. A 21 MHz probe was used on anesthetized male Sprague–Dawley rats to collect images containing the portal vein (PV), superior mesenteric vein (SMV), abdominal inferior vena cava (IVC), and splenic vein (SpV; used as a landmark in timed studies) and the abdominal aorta (AA). Stable landmarks were established that allowed reproducible quantification of cross-sectional diameters within an animal. The average diameters of vessels measured every 5 min over 45 min remained within 0.75 ± 0.15% (PV), 0.2 ± 0.09% (SMV), 0.5 ± 0.12% (IVC), and 0.38 ± 0.06% (AA) of baseline (PV: 2.0 ± 0.12 mm; SMV: 1.7 ± 0.04 mm; IVC: 3.2 ± 0.1 mm; AA: 2.3 ± 0.14 mm). The maximal effects of the vasodilator sodium nitroprusside (SNP; 2 mg/kg, i.v. bolus) on venous diameters were determined 5 min post SNP bolus; the diameters of all noted veins were significantly increased by SNP, while mean arterial pressure (MAP) decreased 29 ± 4 mmHg. By contrast, administration of the venoconstrictor sarafotoxin (S6c; 5 ng/kg, i.v. bolus) significantly decreased PV and SpV, but not IVC, SMV, or AA, diameters 5 min post S6c bolus; MAP increased by 6 ± 2 mmHg. In order to determine if resting splanchnic vein diameters were stable over much longer periods of time, vessel diameters were measured every 2 weeks for 8 weeks. Measurements were found to be highly reproducible within animals over this time period. Finally, to evaluate the utility of vein imaging in a chronic condition, images were acquired from 4-week deoxycorticosterone acetate salt (DOCA-salt) hypertensive and normotensive (SHAM) control rats. All vessel diameters increased from baseline while MAP increased (67 ± 4 mmHg) in DOCA-salt rats

  7. Serial Measurements of Splanchnic Vein Diameters in Rats Using High-Frequency Ultrasound.

    PubMed

    Seitz, Bridget M; Krieger-Burke, Teresa; Fink, Gregory D; Watts, Stephanie W

    2016-01-01

    The purpose of this study was to investigate serial ultrasound imaging in rats as a fully non-invasive method to (1) quantify the diameters of splanchnic veins in real time as an indirect surrogate for the capacitance function of those veins, and (2) assess the effects of drugs on venous dimensions. A 21 MHz probe was used on anesthetized male Sprague-Dawley rats to collect images containing the portal vein (PV), superior mesenteric vein (SMV), abdominal inferior vena cava (IVC), and splenic vein (SpV; used as a landmark in timed studies) and the abdominal aorta (AA). Stable landmarks were established that allowed reproducible quantification of cross-sectional diameters within an animal. The average diameters of vessels measured every 5 min over 45 min remained within 0.75 ± 0.15% (PV), 0.2 ± 0.09% (SMV), 0.5 ± 0.12% (IVC), and 0.38 ± 0.06% (AA) of baseline (PV: 2.0 ± 0.12 mm; SMV: 1.7 ± 0.04 mm; IVC: 3.2 ± 0.1 mm; AA: 2.3 ± 0.14 mm). The maximal effects of the vasodilator sodium nitroprusside (SNP; 2 mg/kg, i.v. bolus) on venous diameters were determined 5 min post SNP bolus; the diameters of all noted veins were significantly increased by SNP, while mean arterial pressure (MAP) decreased 29 ± 4 mmHg. By contrast, administration of the venoconstrictor sarafotoxin (S6c; 5 ng/kg, i.v. bolus) significantly decreased PV and SpV, but not IVC, SMV, or AA, diameters 5 min post S6c bolus; MAP increased by 6 ± 2 mmHg. In order to determine if resting splanchnic vein diameters were stable over much longer periods of time, vessel diameters were measured every 2 weeks for 8 weeks. Measurements were found to be highly reproducible within animals over this time period. Finally, to evaluate the utility of vein imaging in a chronic condition, images were acquired from 4-week deoxycorticosterone acetate salt (DOCA-salt) hypertensive and normotensive (SHAM) control rats. All vessel diameters increased from baseline while MAP increased (67 ± 4 mmHg) in DOCA-salt rats

  8. Shrinking plastic tubing and nonstandard diameters

    NASA Technical Reports Server (NTRS)

    Ruiz, W. V.; Thatcher, C. S.

    1980-01-01

    Process allows larger-than-normal postshrink diameters without splitting. Tetrafluoroethylene tubing on mandrel is supported within hot steel pipe by several small diameter coil sections. Rising temperature of mandrel is measured via thermocouple so assembly can be removed without overshrinking (and splitting) of tubing.

  9. 1,2,4-Tribromobenzene

    Integrated Risk Information System (IRIS)

    1,2,4 - Tribromobenzene ; CASRN 615 - 54 - 3 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcin

  10. 1,2,3-Trichloropropane

    Integrated Risk Information System (IRIS)

    1,2,3 - Trichloropropane ; CASRN 96 - 18 - 4 Human health assessment information on a chemical substance is included in IRIS only after a comprehensive review of toxicity data by U.S . EPA health scientists from several program offices , regional offices , and the Office of Research and Development

  11. trans-1,2-Dichloroethylene

    Integrated Risk Information System (IRIS)

    trans - 1,2 - Dichloroethylene ; CASRN 156 - 60 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for No

  12. 1,1,2-Trichloropropane

    Integrated Risk Information System (IRIS)

    1,1,2 - Trichloropropane ; CASRN 598 - 77 - 6 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarci

  13. 1,1,2-Trichloroethane

    Integrated Risk Information System (IRIS)

    1,1,2 - Trichloroethane ; CASRN 79 - 00 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcino

  14. 1,2,4-Trichlorobenzene

    Integrated Risk Information System (IRIS)

    1,2,4 - Trichlorobenzene ; CASRN 120 - 82 - 1 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarci

  15. cis-1,2-Dichloroethylene

    Integrated Risk Information System (IRIS)

    cis - 1,2 - Dichloroethylene ; CASRN 156 - 59 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Nonc

  16. 1,2-Epoxybutane (EBU)

    Integrated Risk Information System (IRIS)

    1,2 - Epoxybutane ( EBU ) ; CASRN 106 - 88 - 7 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarc

  17. Dark filaments observed at 8.3mm and 3.1mm wavelength

    NASA Technical Reports Server (NTRS)

    Hiel, E.; Ishiguro, M.; Kosugi, T.; Shibasaki, K.

    1986-01-01

    Mapping of the sun was made at 3.1mm (98 GHz) and 8.3mm (36 GHz) wavelengths with a 45m dish radio telescope at the Nobeyama Cosmic Radio Observatory. The depressions associated with large H alpha filaments are derived to be -0.2 at 8.3mm and -0.05 at 3.1mm, which are darker than the values inferred by Raoult et al. (1979)

  18. Hoop tensile strength testing of small diameter ceramic particles

    NASA Astrophysics Data System (ADS)

    Wereszczak, A. A.; Jadaan, O. M.; Lin, H.-T.; Champoux, G. J.; Ryan, D. P.

    2007-03-01

    A method to measure hoop tensile strength of 1-mm-diameter brittle ceramic spheres was demonstrated through the use of a 'C-sphere' flexure strength specimen. This innovative specimen geometry was chosen because a simple, monotonically increasing uniaxial compressive force produces a hoop tensile stress at the C-sphere's outer surface that ultimately initiates fracture. This enables strength quantification and strength-limiting-flaw identification of the sphere itself. Such strength information is relevant to design optimization and durability assessments of ceramic fuel particles and breeder/multiplier pebbles for fusion when particle surfaces are subjected to tensile stresses during their manufacturing or service.

  19. Note: Computer controlled rotation mount for large diameter optics

    NASA Astrophysics Data System (ADS)

    Rakonjac, Ana; Roberts, Kris O.; Deb, Amita B.; Kjærgaard, Niels

    2013-02-01

    We describe the construction of a motorized optical rotation mount with a 40 mm clear aperture. The device is used to remotely control the power of large diameter laser beams for a magneto-optical trap. A piezo-electric ultrasonic motor on a printed circuit board provides rotation with a precision better than 0.03° and allows for a very compact design. The rotation unit is controlled from a computer via serial communication, making integration into most software control platforms straightforward.

  20. Photoacoustic determination of blood vessel diameter

    NASA Astrophysics Data System (ADS)

    Kolkman, Roy G. M.; Klaessens, John H. G. M.; Hondebrink, Erwin; Hopman, Jeroen C. W.; de Mul, Frits F. M.; Steenbergen, Wiendelt; Thijssen, Johan M.; van Leeuwen, Ton G.

    2004-10-01

    A double-ring sensor was applied in photoacoustic tomographic imaging of artificial blood vessels as well as blood vessels in a rabbit ear. The peak-to-peak time (tgrpp) of the laser (1064 nm) induced pressure transient was used to estimate the axial vessel diameter. Comparison with the actual vessel diameter showed that the diameter could be approximated by 2ctgrpp, with c the speed of sound in blood. Using this relation, the lateral diameter could also precisely be determined. In vivo imaging and monitoring of changes in vessel diameters was feasible. Finally, acoustic time traces were recorded while flushing a vessel in the rabbit ear with saline, which proved that the main contribution to the laser-induced pressure transient is caused by blood inside the vessel and that the vessel wall gives only a minor contribution.

  1. 40 CFR Table 1 to Subpart Mm of... - General Provisions Applicability to Subpart MM

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ....860. 63.1(b)(2) Title V operating permit—see 40 CFR part 70 Yes All major affected sources are... Subpart MM 1 Table 1 to Subpart MM of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Combustion Sources at Kraft, Soda, Sulfite, and Stand-Alone Semichemical Pulp Mills Pt. 63, Subpt. MM,...

  2. 40 CFR Table 1 to Subpart Mm of... - General Provisions Applicability to Subpart MM

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ....860. 63.1(b)(2) Title V operating permit—see 40 CFR part 70 Yes All major affected sources are... Subpart MM 1 Table 1 to Subpart MM of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Combustion Sources at Kraft, Soda, Sulfite, and Stand-Alone Semichemical Pulp Mills Pt. 63, Subpt. MM,...

  3. 40 CFR Table 1 to Subpart Mm of... - General Provisions Applicability to Subpart MM

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ....860. 63.1(b)(2) Title V operating permit—see 40 CFR part 70 Yes All major affected sources are... Subpart MM 1 Table 1 to Subpart MM of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Combustion Sources at Kraft, Soda, Sulfite, and Stand-Alone Semichemical Pulp Mills Pt. 63, Subpt. MM,...

  4. 40 CFR Table 1 to Subpart Mm of... - General Provisions Applicability to Subpart MM

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ....860. 63.1(b)(2) Title V operating permit—see 40 CFR part 70 Yes All major affected sources are... Subpart MM 1 Table 1 to Subpart MM of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Combustion Sources at Kraft, Soda, Sulfite, and Stand-Alone Semichemical Pulp Mills Pt. 63, Subpt. MM,...

  5. 40 CFR Table 1 to Subpart Mm of... - General Provisions Applicability to Subpart MM

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ....860. 63.1(b)(2) Title V operating permit—see 40 CFR part 70 Yes All major affected sources are... Subpart MM 1 Table 1 to Subpart MM of Part 63 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Combustion Sources at Kraft, Soda, Sulfite, and Stand-Alone Semichemical Pulp Mills Pt. 63, Subpt. MM,...

  6. Laparoscopic cholecystectomy using 2-mm instruments.

    PubMed

    Uranüs, S; Peng, Z; Kronberger, L; Pfeifer, J; Salehi, B

    1998-10-01

    Today, laparoscopic cholecystectomy is the method of choice for treatment of symptomatic gallbladder disorders. It minimizes effects of the operation that are independent of the gallbladder, such as trauma to the abdominal wall and other soft tissue. The surgical wounds were even smaller when 2-mm trocars were used. Laparoscopic cholecystectomy using 2-mm instruments was performed in a consecutive series of 14 patients with symptomatic gallstones. The procedure was completed in 12 cases, with conversion to open surgery in two cases. Intraoperative cholangiography was always performed. The postoperative course was always uneventful. The cosmetic effect was highly satisfactory. The procedure using 2-mm instruments could be indicated in selected patients with uncomplicated gallstone disease. PMID:9820716

  7. Microeconomics of 300-mm process module control

    NASA Astrophysics Data System (ADS)

    Monahan, Kevin M.; Chatterjee, Arun K.; Falessi, Georges; Levy, Ady; Stoller, Meryl D.

    2001-08-01

    Simple microeconomic models that directly link metrology, yield, and profitability are rare or non-existent. In this work, we validate and apply such a model. Using a small number of input parameters, we explain current yield management practices in 200 mm factories. The model is then used to extrapolate requirements for 300 mm factories, including the impact of simultaneous technology transitions to 130nm lithography and integrated metrology. To support our conclusions, we use examples relevant to factory-wide photo module control.

  8. Turbulent Concentration of mm-Size Particles in the Protoplanetary Nebula: Scale-Dependent Cascades

    NASA Technical Reports Server (NTRS)

    Cuzzi, J. N.; Hartlep, T.

    2015-01-01

    The initial accretion of primitive bodies (here, asteroids in particular) from freely-floating nebula particles remains problematic. Traditional growth-by-sticking models encounter a formidable "meter-size barrier" (or even a mm-to-cm-size barrier) in turbulent nebulae, making the preconditions for so-called "streaming instabilities" difficult to achieve even for so-called "lucky" particles. Even if growth by sticking could somehow breach the meter size barrier, turbulent nebulae present further obstacles through the 1-10km size range. On the other hand, nonturbulent nebulae form large asteroids too quickly to explain long spreads in formation times, or the dearth of melted asteroids. Theoretical understanding of nebula turbulence is itself in flux; recent models of MRI (magnetically-driven) turbulence favor low-or- no-turbulence environments, but purely hydrodynamic turbulence is making a comeback, with two recently discovered mechanisms generating robust turbulence which do not rely on magnetic fields at all. An important clue regarding planetesimal formation is an apparent 100km diameter peak in the pre-depletion, pre-erosion mass distribution of asteroids; scenarios leading directly from independent nebula particulates to large objects of this size, which avoid the problematic m-km size range, could be called "leapfrog" scenarios. The leapfrog scenario we have studied in detail involves formation of dense clumps of aerodynamically selected, typically mm-size particles in turbulence, which can under certain conditions shrink inexorably on 100-1000 orbit timescales and form 10-100km diameter sandpile planetesimals. There is evidence that at least the ordinary chondrite parent bodies were initially composed entirely of a homogeneous mix of such particles. Thus, while they are arcane, turbulent concentration models acting directly on chondrule size particles are worthy of deeper study. The typical sizes of planetesimals and the rate of their formation can be

  9. Turbulent Concentration of MM-Size Particles in the Protoplanetary Nebula: Scaled-Dependent Multiplier Functions

    NASA Technical Reports Server (NTRS)

    Cuzzi, Jeffrey N.; Hartlep, Thomas; Weston, B.; Estremera, Shariff Kareem

    2014-01-01

    The initial accretion of primitive bodies (asteroids and TNOs) from freely-floating nebula particles remains problematic. Here we focus on the asteroids where constituent particle (read "chondrule") sizes are observationally known; similar arguments will hold for TNOs, but the constituent particles in those regions will be smaller, or will be fluffy aggregates, and are unobserved. Traditional growth-bysticking models encounter a formidable "meter-size barrier" [1] (or even a mm-cm-size barrier [2]) in turbulent nebulae, while nonturbulent nebulae form large asteroids too quickly to explain long spreads in formation times, or the dearth of melted asteroids [3]. Even if growth by sticking could somehow breach the meter size barrier, other obstacles are encountered through the 1-10km size range [4]. Another clue regarding planetesimal formation is an apparent 100km diameter peak in the pre-depletion, pre-erosion mass distribution of asteroids [5]; scenarios leading directly from independent nebula particulates to this size, which avoid the problematic m-km size range, could be called "leapfrog" scenarios [6-8]. The leapfrog scenario we have studied in detail involves formation of dense clumps of aerodynamically selected, typically mm-size particles in turbulence, which can under certain conditions shrink inexorably on 100-1000 orbit timescales and form 10-100km diameter sandpile planetesimals. The typical sizes of planetesimals and the rate of their formation [7,8] are determined by a statistical model with properties inferred from large numerical simulations of turbulence [9]. Nebula turbulence can be described by its Reynolds number Re = L/eta sup(4/3), where L = ETA alpha sup (1/2) the largest eddy scale, H is the nebula gas vertical scale height, and a the nebula turbulent viscosity parameter, and ? is the Kolmogorov or smallest scale in turbulence (typically about 1km), with eddy turnover time t?. In the nebula, Re is far larger than any numerical simulation can

  10. Measurement of shaft diameters by machine vision.

    PubMed

    Wei, Guang; Tan, Qingchang

    2011-07-01

    A machine vision method for accurately measuring the diameters of cylindrical shafts is presented. Perspective projection and the geometrical features of cylindrical shafts are modeled in order to enable accurate measurement of shaft diameters. Some of the model parameters are determined using a shaft of known diameter. The camera model itself includes radial and tangential distortions terms. Experiments were used to measure the accuracy of the proposed method and the effect of the position of the camera relative to the shaft, as well as other factors. PMID:21743525

  11. Correlation of the ratio of caudal vena cava diameter and aorta diameter with systolic pressure variation in anesthetized dogs.

    PubMed

    Meneghini, Caterina; Rabozzi, Roberto; Franci, Paolo

    2016-02-01

    OBJECTIVE To evaluate the correlation coefficient of the ratio between diameter of the caudal vena cava (CVC) and diameter of the aorta (Ao) in dogs as determined ultrasonographically with systolic pressure variation (SPV). ANIMALS 14 client-owned dogs (9 females and 5 males; mean ± SD age, 73 ± 40 months; mean body weight, 22 ± 7 kg) that underwent anesthesia for repair of skin wounds. PROCEDURES Anesthesia was induced. Controlled mechanical ventilation with a peak inspiratory pressure of 8 cm H2O was immediately started, and SPV was measured. During a brief period of suspension of ventilation, CVC-to-Ao ratio was measured on a transverse right-lateral intercostal ultrasonographic image obtained at the level of the porta hepatis. When the SPV was ≥ 4 mm Hg, at least 1 bolus (3 to 4 mL/kg) of Hartmann solution was administered IV during a 1-minute period. Bolus administration was stopped and the CVC-to-Ao ratio measured when SPV was < 4 mm Hg. Correlation coefficient analysis was performed. RESULTS 28 measurements were obtained. The correlation coefficient was 0.86 (95% confidence interval, 0.72 to 0.93). Mean ± SD SPV and CVC-to-Ao ratio before bolus administration were 7 ± 2 mm Hg and 0.52 ± 0.16, respectively. Mean ± SD SPV and CVC-to-Ao ratio after bolus administration were 2 ± 0.6 mm Hg and 0.91 ± 0.13, respectively. CONCLUSIONS AND CLINICAL RELEVANCE In this study, the CVC-to-Ao ratio was a feasible, noninvasive ultrasonographically determined value that correlated well with SPV. (Am J Vet Res 2016;77:137-143). PMID:27027706

  12. Diameter prediction mathematical models for xanthan gum-alginate capsules produced by extrusion-dripping method

    NASA Astrophysics Data System (ADS)

    Ong, Hui-Yen; Lee, Boon-Beng; Zakaria, Zarina; Chan, Eng-Seng

    2015-05-01

    The aim of this work is to compare the applicability of particle diameter prediction mathematical models (i.e. Tate's Law equation, the modified Tate's Law equation, the modified Yildirim's model) to determine diameter of liquid core capsules. The capsules were produced by extruding xanthan gum-calcium chloride solution through a hypodermic needle into sodium alginate solution. The effects of two types of xanthan gum with different concentrations and needle diameters on capsule diameter were investigated in this work. The results showed that there was no significant difference in capsule diameter despite different types and concentrations of xanthan gum were used. However, the diameter of the capsules increased when the diameter of needles increased. As a whole, the produced capsules were in the range of 3.47 mm to 4.86 mm. Among the three studied prediction models, the modified Tate's Law mathematical equation was the most suitable model for the diameter prediction of the liquid core capsules with AAD of 2.74% and MAD of 6.55%.

  13. Optimizing digital 8mm drive performance

    NASA Technical Reports Server (NTRS)

    Schadegg, Gerry

    1993-01-01

    The experience of attaching over 350,000 digital 8mm drives to 85-plus system platforms has uncovered many factors which can reduce cartridge capacity or drive throughput, reduce reliability, affect cartridge archivability and actually shorten drive life. Some are unique to an installation. Others result from how the system is set up to talk to the drive. Many stem from how applications use the drive, the work load that's present, the kind of media used and, very important, the kind of cleaning program in place. Digital 8mm drives record data at densities that rival those of disk technology. Even with technology this advanced, they are extremely robust and, given proper usage, care and media, should reward the user with a long productive life. The 8mm drive will give its best performance using high-quality 'data grade' media. Even though it costs more, good 'data grade' media can sustain the reliability and rigorous needs of a data storage environment and, with proper care, give users an archival life of 30 years or more. Various factors, taken individually, may not necessarily produce performance or reliability problems. Taken in combination, their effects can compound, resulting in rapid reductions in a drive's serviceable life, cartridge capacity, or drive performance. The key to managing media is determining the importance one places upon their recorded data and, subsequently, setting media usage guidelines that can deliver data reliability. Various options one can implement to optimize digital 8mm drive performance are explored.

  14. MM-122: High speed civil transport

    NASA Technical Reports Server (NTRS)

    Demarest, Bill; Anders, Kurt; Manchec, John; Yang, Eric; Overgaard, Dan; Kalkwarf, Mike

    1992-01-01

    The rapidly expanding Pacific Rim market along with other growing markets indicates that the future market potential for a high speed civil transport is great indeed. The MM-122 is the answer to the international market desire for a state of the art, long range, high speed civil transport. It will carry 250 passengers a distance of 5200 nm at over twice the speed of sound. The MM-122 is designed to incorporate the latest technologies in the areas of control systems, propulsions, aerodynamics, and materials. The MM-122 will accomplish these goals using the following design parameters. First, a double delta wing planform with highly swept canards and an appropriately area ruled fuselage will be incorporated to accomplish desired aerodynamic characteristics. Propulsion will be provided by four low bypass variable cycle turbofan engines. A quad-redundant fly-by-wire flight control system will be incorporated to provide appropriate static stability and level 1 handling qualities. Finally, the latest in conventional metallic and modern composite materials will be used to provide desired weight and performance characteristics. The MM-122 incorporates the latest in technology and cost minimization techniques to provide a viable solution to this future market potential.

  15. CCM3 to MM5 Data Conversion

    2007-03-02

    The accompanying script (which uses the NCAR Command Language) ready output from the Community Climate Model Code, version 3 (CCM3) and converts it to input format for the Mesoscale Model, version 5 (MM5) code. The script utilizes a Fortran binary write routine.

  16. Mm-wave power meter mount

    NASA Technical Reports Server (NTRS)

    Mullen, D. L.; Oltmans, D. A.; Stelzried, C. T.

    1968-01-01

    E-band thermistor mount and a technique for adjusting a temperature compensating thermistor to provide an electrically balanced bridge are used for measuring RF power in the mm-wavelength. The mount is relatively insensitive to temperature effects that cause measurement errors in single ended circuits.

  17. Growth of nanostructures with controlled diameter

    DOEpatents

    Pfefferle, Lisa; Haller, Gary; Ciuparu, Dragos

    2009-02-03

    Transition metal-substituted MCM-41 framework structures with a high degree of structural order and a narrow pore diameter distribution were reproducibly synthesized by a hydrothermal method using a surfactant and an anti-foaming agent. The pore size and the mesoporous volume depend linearly on the surfactant chain length. The transition metals, such as cobalt, are incorporated substitutionally and highly dispersed in the silica framework. Single wall carbon nanotubes with a narrow diameter distribution that correlates with the pore diameter of the catalytic framework structure were prepared by a Boudouard reaction. Nanostructures with a specified diameter or cross-sectional area can therefore be predictably prepared by selecting a suitable pore size of the framework structure.

  18. Characterization of Detonation Wave Propagation in LX-17 Near the Critical Diameter

    SciTech Connect

    Tran, T D; Tarver, C M; Maienschein, J; Lewis, P; Pastrone, R; Lee, R S; Roeske, F

    2002-06-14

    A new Detonation Profile Test (DPT) was developed to measure simultaneously the detonation wave breakout profile and the average detonation velocity at the breakout surface. The test evaluated small cylindrical samples with diameter up to 19.08 mm and length up to 33 mm. The experiment involved initiating a LX-17 cylindrical specimen and recording the wave breakout using a fast streaking electronic camera. The initiation was done using a PBX-9407 pellet (1.630 g/cm{sup 3}), which has a Chapman-Jouguet (C-J) pressure close to that of LX-17. The acceptor breakout surface had a 2 mm wide by 1 mm deep groove that provided a step in the recorded breakout profile for velocity determination. A 532-nm laser light illuminated the specimen surface. A streak camera looking perpendicular to the groove, recorded the extinction of the laser light as the detonation wave emerged from the surface. This technique provided a high-resolution spatial and temporal profile of the wave curvature as well as accurate timing of the propagating wave over the last millimeter of the sample. The measured groove depth and recorded travel time were then used to calculate the average detonation wave velocity. Results for 12.7 mm diameter unconfined LX-17 charges showed detonation velocity in the range between 6.79 and 7.06 km/s for parts up to 33 mm long. Since LX-17 can not sustain detonation at less than 7.3 km/s , these waves were definitely failing. Experiments with confined 12.7 mm diameter and unconfined 19.1 mm diameter samples showed wave velocities in the range of 7.4-7.6 km/s, values approaching steady state conditions at infinite diameter. Both unconfined and confined charges show no sensitivity to density variations in the range between 1.890-1.915 g/cm{sup 3}. Experiments with 15.88 mm and 19.08 mm diameters gave velocities in the range between 7.2-7.45 km/s, values close to that expected for failure. The velocity measurement has an estimated experimental error in the range of 2

  19. Substrate diameter and compliance affect the gripping strategies and locomotor mode of climbing boa constrictors.

    PubMed

    Byrnes, Greg; Jayne, Bruce C

    2010-12-15

    Arboreal habitats pose unique challenges for locomotion as a result of their narrow cylindrical surfaces and discontinuities between branches. Decreased diameter of branches increases compliance, which can pose additional challenges, including effects on stability and energy damping. However, the combined effects of substrate diameter and compliance are poorly understood for any animal. We quantified performance, kinematics and substrate deformation while boa constrictors (Boa constrictor) climbed vertical ropes with three diameters (3, 6 and 9 mm) and four tensions (0.5, 1.0, 1.5 and 2.0 body weights). Mean forward velocity decreased significantly with both decreased diameter and increased compliance. Both diameter and compliance had numerous effects on locomotor kinematics, but diameter had larger and more pervasive effects than compliance. Locomotion on the largest diameter had a larger forward excursion per cycle, and the locomotor mode and gripping strategy differed from that on the smaller diameters. On larger diameters, snakes primarily applied opposing forces at the same location on the rope to grip. By contrast, on smaller diameters forces were applied in opposite directions at different locations along the rope, resulting in increased rope deformation. Although energy is likely to be lost during deformation, snakes might use increased surface deformation as a strategy to enhance their ability to grip. PMID:21113006

  20. The Use of Narrow Diameter Implants in the Molar Area.

    PubMed

    Saad, M; Assaf, A; Gerges, E

    2016-01-01

    Implant rehabilitations in the posterior jaw are influenced by many factors such as the condition of the remaining teeth, the force factors related to the patient, the quality of the bone, the maintenance of the hygiene, the limited bone height, the type and extent of edentulism, and the nature of the opposing arch. The gold standard is to place a regular diameter implant (>3.7 mm) or a wide one to replace every missing molar. Unfortunately, due to horizontal bone resorption, this option is not possible without lateral bone augmentation. In this situation, narrow diameter implant (NDI < 3.5 mm) could be the alternative to lateral bone augmentation procedures. This paper presents a clinical study where NDIs were used for the replacement of missing molars. They were followed up to 11 years. Special considerations were observed and many parameters were evaluated. NDI could be used to replace missing molar in case of moderate horizontal bone resorption if strict guidelines are respected. Yet, future controlled prospective clinical trials are required to admit their use as scientific evidence. PMID:27293436

  1. The Use of Narrow Diameter Implants in the Molar Area

    PubMed Central

    Saad, M.; Assaf, A.; Gerges, E.

    2016-01-01

    Implant rehabilitations in the posterior jaw are influenced by many factors such as the condition of the remaining teeth, the force factors related to the patient, the quality of the bone, the maintenance of the hygiene, the limited bone height, the type and extent of edentulism, and the nature of the opposing arch. The gold standard is to place a regular diameter implant (>3.7 mm) or a wide one to replace every missing molar. Unfortunately, due to horizontal bone resorption, this option is not possible without lateral bone augmentation. In this situation, narrow diameter implant (NDI < 3.5 mm) could be the alternative to lateral bone augmentation procedures. This paper presents a clinical study where NDIs were used for the replacement of missing molars. They were followed up to 11 years. Special considerations were observed and many parameters were evaluated. NDI could be used to replace missing molar in case of moderate horizontal bone resorption if strict guidelines are respected. Yet, future controlled prospective clinical trials are required to admit their use as scientific evidence. PMID:27293436

  2. Measurements of Pupillary Diameter and Wavefront Aberrations in Pregnant Women

    PubMed Central

    Altay, Mehmet Metin; Demirok, Gulizar; Balta, Ozgur; Bolu, Hulya

    2016-01-01

    Purpose. To show whether pregnancy affects the measurements of pupillary diameter and wavefront (WF) aberrations. Methods. This was a case-control study including 34 healthy pregnant women in the third trimester and age-matched 34 nonpregnant women. Only women who had no ocular abnormalities and no refractive error were included. We measured photopic and mesopic pupil diameter and WF aberrations at the third trimester and at the second postpartum month. Measurements of the right eyes were used in this study. The differences between groups were analysed by paired t-test and t-test. Results. Pregnant women's mean photopic pupil size in the third trimester was significantly higher than in postpartum period and in control group (3.74 ± 0.77, 3.45 ± 0.53, and 3.49 ± 0.15 mm, p < 0.05, resp.). Mesopic pupil size in the third trimester was also higher than in postpartum period and in control group (6.77 ± 0.52, 6.42 ± 0.55, and 6.38 ± 0.21 mm, p < 0.05, resp.). RMS-3 and RMS-5 values were higher in pregnancy but these differences were not statistically significant. Conclusion. Pregnancy increased photopic and mesopic pupil size significantly but did not increase wavefront aberrations notably. Increased pupil size may be due to increased sympathetic activity during pregnancy. And this activity can be noninvasively determined by measuring pupil size. PMID:26998383

  3. Making Jointless Dual-Diameter Tubes

    NASA Technical Reports Server (NTRS)

    Kirkham, Kathleen E.

    1989-01-01

    Welds between sections having different diameters eliminated. Single tube made with integral tapered transition section between straight sections of different diameters and wall thicknesses. Made from single piece; contains no joints, welded or otherwise. Not prone to such weld defects as voids and need not be inspected for them. Tube fabricated by either of two methods: drawing or reduction. Both methods used to fabricate tubes of 316L corrosion-resistant stainless steel for use as heat-exchanger coil.

  4. Ultra-efficient Engine Diameter Study

    NASA Technical Reports Server (NTRS)

    Daggett, David L.; Brown, Stephen T.; Kawai, Ron T.

    2003-01-01

    Engine fan diameter and Bypass Ratio (BPR) optimization studies have been conducted since the beginning of the turbofan age with the recognition that reducing the engine core jet velocity and increasing fan mass flow rate generally increases propulsive efficiency. However, performance tradeoffs limit the amount of fan flow achievable without reducing airplane efficiency. This study identifies the optimum engine fan diameter and BPR, given the advanced Ultra-Efficient Engine Technology (UEET) powerplant efficiencies, for use on an advanced subsonic airframe. Engine diameter studies have historically focused on specific engine size options, and were limited by existing technology and transportation infrastructure (e.g., ability to fit bare engines through aircraft doors and into cargo holds). This study is unique in defining the optimum fan diameter and drivers for future 2015 (UEET) powerplants while not limiting engine fan diameter by external constraints. This report follows on to a study identifying the system integration issues of UEET engines. This Engine Diameter study was managed by Boeing Phantom Works, Seattle, Washington through the NASA Glenn Revolutionary Aero Space Engine Research (RASER) contract under task order 10. Boeing Phantom Works, Huntington Beach, completed the engine/airplane sizing optimization, while the Boeing Commercial Airplane group (BCA) provided design oversight. A separate subcontract to support the overall project was issued to Tuskegee University.

  5. A New Laboratory for MM-/Sub-MM-Wave Characterization of Cosmic Dust Analogs

    NASA Astrophysics Data System (ADS)

    Birsa, Samuel; Do, Huy; Williams, Frederick; Liu, Lunjun; Schonert, Ryan; Perera, Thushara

    2015-01-01

    Most studies conducted with observatories such as ALMA, SOFIA, PLANCK, and Herschel will benefit from knowledge of (1) the predominant cosmic dust species in various environments, in terms of composition and structure and (2) mm/sub-mm optical properties of cosmic dusts, including the temperature dependent-emissivity and spectral index. A new laboratory has been established for producing and characterizing (in the mm/sub-mm) various silicate/carbonaceous dust candidates. In particular, the optical measurement setup was custom designed, specifically for laboratory studies of dusts, using techniques borrowed from observational cosmology. It features novel designs for a compact Fourier Transform Spectrometer (FTS) and a cold sample holder/exchanger. Construction of this apparatus is now complete; we are currently testing the system. Here, we present the mm/sub-mm measurement scheme and highlight its innovative and aspects.

  6. Influence of coronary artery diameter on eNOS protein content

    NASA Technical Reports Server (NTRS)

    Laughlin, M. H.; Turk, J. R.; Schrage, W. G.; Woodman, C. R.; Price, E. M.

    2003-01-01

    The purpose of this study was to test the hypothesis that the content of endothelial nitric oxide synthase (eNOS) protein (eNOS protein/g total artery protein) increases with decreasing artery diameter in the coronary arterial tree. Content of eNOS protein was determined in porcine coronary arteries with immunoblot analysis. Arteries were isolated in six size categories from each heart: large arteries [301- to 2,500-microm internal diameter (ID)], small arteries (201- to 300-microm ID), resistance arteries (151- to 200-microm ID), large arterioles (101- to 150-microm ID), intermediate arterioles (51- to 100-microm ID), and small arterioles(<50-microm ID). To obtain sufficient protein for analysis from small- and intermediate-sized arterioles, five to seven arterioles 1-2 mm in length were pooled into one sample for each animal. Results establish that the number of smooth muscle cells per endothelial cell decreases from a number of 10 to 15 in large coronary arteries to 1 in the smallest arterioles. Immunohistochemistry revealed that eNOS is located only in endothelial cells in all sizes of coronary artery and in coronary capillaries. Contrary to our hypothesis, eNOS protein content did not increase with decreasing size of coronary artery. Indeed, the smallest coronary arterioles had less eNOS protein per gram of total protein than the large coronary arteries. These results indicate that eNOS protein content is greater in the endothelial cells of conduit arteries, resistance arteries, and large arterioles than in small coronary arterioles.

  7. Optic nerve sheath diameters in healthy adults measured by computer tomography

    PubMed Central

    Vaiman, Michael; Abuita, Rani; Bekerman, Inessa

    2015-01-01

    AIM To measure optic nerve sheath diameters (ONSD) in different locations by computer tomography (CT) and to recommend the best location for cases when ONSD is used for intracranial pressure monitoring. METHODS In a prospective cohort study, CT data of 300 healthy adults were analyzed (600 eyes). In all cases, the CT investigation was performed at the Emergency Department because of the various conditions that proved not to be connected with ophthalmological or neurological pathology. The ONSD were measured at 3 mm and 8 mm distance from the globe, and 3 mm from the anterior opening of the optic canal. The correlation analysis was performed with gender, age, and ethnic background. RESULTS The right/left ONSD are 4.94±1.51/5.17±1.34 mm at 3 mm, 4.35±0.76/4.45±0.62 mm at 8 mm from the globe, and 3.55±0.82/3.65±0.7 mm at 3 mm from the optic canal. No significant differences correlated with gender of the patients, their age, and ethnic background were found. CONCLUSION In healthy persons, the ONSD varies from 5.17±1.34 mm to 3.55±0.82 mm in different locations within the intraorbital space. The most stable results with lesser standard deviation can be obtained if it is measured 8-10 mm from the globe. PMID:26682181

  8. Maximum Diameter of Native Abdominal Aortic Aneurysm Measured by Angio-Computed Tomography

    PubMed Central

    Mora, Caroline E.; Marcus, Claude D.; Barbe, Coralie M.; Ecarnot, Fiona B.; Long, Anne L.

    2015-01-01

    Background: Computed tomography angiography (CTA) is the reference technique for the measurement of native maximum abdominal aortic aneurysm (AAA) diameter when surgery is being considered. However, there is a wide choice available for the methodology of maximum AAA diameter measurement on CTA, and to date, no consensus has been reached on which method is best. We analyzed clinical decisions based on these various measures of native maximum AAA diameter with CTA, then analyzed their reproducibility and identified the method of measurement yielding the highest agreement in terms of patient management. Materials and Methods: Three sets of measures in 46 native AAA were obtained, double-blind by three radiologists (J, S, V) on orthogonal planes, curved multiplanar reconstructions, and semi-automated-software, based on the AAA-lumen centerline. From each set, the clinical decision was recorded as follows: "Follow-up" (if all diameters <50 mm), "ambiguous" (if at least one diameter <50 mm AND at least one ≥50 mm) or "Surgery " (if all diameters ≥50 mm). Intra- and interobserver agreements in clinical decisions were compared using the weighted Kappa coefficient. Results: Clinical decisions varied according to the measurement sets used by each observer, and according to intra and interobserver (lecture#1) reproducibility. Based on the first reading of each observer, the number of AAA proposed for surgery ranged from 11 to 24 for J, 5 to 20 for S, and 15 to 23 for V. The rate of AAAs classified as "ambiguous" varied from 11% (5/46) to 37% (17/46). The semi-automated method yielded very good intraand interobserver agreements in clinical decisions in all comparisons (Kappa range 0.83–1.00). Conclusion: The semi-automated method seems to be appropriate for native AAA maximum diameter measurement on CTA. In the absence of AAA outer-wallbased software more robust for complex AAA, clinical decisions might best be made with diameter values obtained using this technique

  9. Validating a Nonhuman Primate Model of Super-Selective Intraophthalmic Artery Chemotherapy: Comparing Ophthalmic Artery Diameters

    PubMed Central

    Ditta, Lauren C.; Choudhri, Asim F.; Tse, Brian C.; Landers, Mark M.; Haik, Barrett G.; Steinle, Jena J.; Williams, J. Scott; Wilson, Matthew W.

    2012-01-01

    Purpose. Superselective intraophthalmic artery chemotherapy (SSIOAC) is being used for treatment of retinoblastoma; however, the hemodynamic consequences and toxicities are not fully known. We developed a nonhuman primate (NHP) model of SSIOAC and reported our clinical observations. For validation, we compared ophthalmic artery (OA) diameters between NHPs and children (<6 years). Methods. Endovascular cannulation of the right OA was performed three times each in six adult male Rhesus macaques. Angiographic OA images were obtained and measured, and postmortem OAs were histologically sectioned and measured. Retrospectively, computed tomography (CT) and magnetic resonance (MR) angiography images of the head in children and adolescents (as an adult reference) were used to measure the OA luminal diameter at its origin. Results. The median angiographic diameter of treated NHP OA origins (n = 6) was 1.06 mm (range 0.94–1.56). Histologic measurements (8 of 12 NHP OAs) gave a median diameter of 1.09 mm (range 0.95–1.41). In 98 children (from 169 consecutive CT and MR angiography studies; median age 1.01 years, range 0.01–5.74), 186 OAs were measurable at the origin (median luminal diameter 1.28 mm, range 0.82–2.00; P = 0.16 for the angiographic NHP diameters versus pediatric cohort). Angiographic measurements of 34 OAs (of 20 consecutive studies of adolescents; median age 16.55 years, range 14.40–18.18) gave a median luminal diameter of 1.45 mm (origin, range 1.13–1.66; P < 0.0001, adolescent versus pediatric). Conclusions. Measurements of the OA luminal diameter at its origin were similar between our NHP and pediatric cohort, validating our NHP model for testing both the hemodynamic consequences and toxicities of SSIOAC. PMID:23111611

  10. Development of Small Diameter Nanofiber Tissue Engineered Arterial Grafts

    PubMed Central

    Tara, Shuhei; Rocco, Kevin A.; Bagi, Paul S.; Yi, Tai; Udelsman, Brooks; Zhuang, Zhen W.; Cleary, Muriel; Iwakiri, Yasuko; Breuer, Christopher K.; Shinoka, Toshiharu

    2015-01-01

    The surgical repair of heart and vascular disease often requires implanting synthetic grafts. While synthetic grafts have been successfully used for medium-to-large sized arteries, applications for small diameter arteries (<6 mm) is limited due to high rates of occlusion by thrombosis. Our objective was to develop a tissue engineered vascular graft (TEVG) for small diameter arteries. TEVGs composed of polylactic acid nanofibers with inner luminal diameter between 0.5 and 0.6 mm were surgically implanted as infra-renal aortic interposition conduits in 25 female C17SCID/bg mice. Twelve mice were given sham operations. Survival of mice with TEVG grafts was 91.6% at 12 months post-implantation (sham group: 83.3%). No instances of graft stenosis or aneurysmal dilatation were observed over 12 months post-implantation, assessed by Doppler ultrasound and microCT. Histologic analysis of explanted TEVG grafts showed presence of CD31-positive endothelial monolayer and F4/80-positive macrophages after 4, 8, and 12 months in vivo. Cells positive for α-smooth muscle actin were observed within TEVG, demonstrating presence of smooth muscle cells (SMCs). Neo-extracellular matrix consisting mostly of collagen types I and III were observed at 12 months post-implantation. PCR analysis supports histological observations. TEVG group showed significant increases in expressions of SMC marker, collagen-I and III, matrix metalloproteinases-2 and 9, and itgam (a macrophage marker), when compared to sham group. Overall, patency rates were excellent at 12 months after implantation, as structural integrity of these TEVG. Tissue analysis also demonstrated vessel remodeling by autologous cell. PMID:25830942

  11. Comparison between 28 mm and 32 mm ceramic-on-ceramic bearings in total hip replacement.

    PubMed

    Lee, Y K; Ha, Y C; Koo, K H

    2014-11-01

    Large femoral heads have become popular in total hip replacement (THR) as a method of reducing the risk of dislocation. However, if large heads are used in ceramic-on-ceramic THR, the liner must be thinner, which may increase the risk of fracture. To compare the rates of ceramic fracture and dislocation between 28 mm and 32 mm ceramic heads, 120 hips in 109 patients (51 men and 58 women, mean age 49.2 years) were randomised to THR with either a 28 mm or a 32 mm ceramic articulation. A total of 57/60 hips assigned to the 28 mm group and 55/60 hips assigned to the 32 mm group were followed for at least five years. No ceramic component fractures occured in any patient in either group. There was one dislocation in the 32 mm group and none in the 28 mm group (p = 0.464). No hip had detectable wear, focal osteolysis or prosthetic loosening. In our small study the 32 mm ceramic articulation appeared to be safe in terms of ceramic liner fracture. PMID:25371457

  12. Mechanical degradation of biological heart valve tissue induced by low diameter crimping: an early assessment.

    PubMed

    Khoffi, Foued; Heim, Frederic

    2015-04-01

    Transcatheter aortic valve implantation (TAVI) has become today an increasingly attractive procedure to relieve patients from aortic valve disease. However, the procedure requires crimping biological tissue within a metallic stent for low diameter catheter insertion purpose. This step induces specific stress in the leaflets especially when the crimping diameter is small. One concern about crimping is the potential degradations undergone by the biological tissue, which may limit the durability of the valve once implanted. The purpose of the present work is to study the effect of low diameter crimping on the mechanical performances of pericardium valve prototypes. The prototypes were compressed to a diameter of 1mm within braided stents for 20 min. SEM observations performed on crimped material show that crimped leaflets undergo degradations characterized by apparent surface defects. Moreover mechanical extension tests were performed on pericardium strips before and after crimping. The strips (15 mm long, 5mm wide) were taken from both crimped and native leaflets considering 2 different valve diameters, 19 and 21 mm. In order to prevent the premature drying of the pericardium tissue during the procedure, the biological tissue was kept in contact with a formaldehyde solution. Results show that the ultimate strength value decreases nearly by up to 50%. The modifications observed in the material may jeopardize the long term durability of the device. However, further tests are necessary with a larger amount of samples to confirm these early results. PMID:25621851

  13. THE RELATIONSHIP BETWEEN REAL-TIME AND TIME-INTEGRATED COARSE (2.5-10MM), INTERMEDIATE (1-2.5MM), AND FINE (<2.5MM) PARTICULATE MATTER IN THE LOS ANGELES BASIN

    EPA Science Inventory

    Population exposure to ambient particulate matter (PM) has received considerable attention due to the association between ambient particulate concentrations and mortality. Current toxicological and epidemiological studies and controlled human and animal exposures suggest that a...

  14. Experimental demonstration of a 120-mm ram accelerator

    NASA Astrophysics Data System (ADS)

    Kruczynski, David L.

    1992-10-01

    Ram acceleration is an emerging propulsion technology in which a projectile similar in shape to the centerbody of a ramjet aircraft engine is injected at high speed into a tube filled with a combustible gaseous mixture. As the projectile moves into the tube, under supersonic conditions, shocks occur on and around the projectile. If the gases are then ignited either by the energy in the shock system or an external mechanism, the combustion around or behind the projectile can be self-sustaining. The net effect is to generate a localized high pressure region around and/or behind the projectile which produces acceleration. Work at the University of Washington, Seattle, has demonstrated velocities in excess of 2.6 km/s in 38-mm caliber, while theory predicts velocities above 7 km/s may be obtainable. A program was initiated at the Weapons Technology Directorate of the US Army Research Laboratory (formerly Ballistic Research Laboratory) to examine the scaling potential of ram acceleration for use as a high velocity, high mass, (i.e., high kinetic energy) launcher. Data from initial gas mixing tests and first firings through a 120-mm bore diameter ram accelerator with both inert and live fuel gases are presented. Initial comparisons with ram accelerators of smaller scale are made. Discussions of scaling parameters as currently understood will be presented.

  15. Biologically Inspired mm-size Gliding UAV

    NASA Astrophysics Data System (ADS)

    Weihs, Daniel; Zussman, Eyal; Yarin, Alexander

    2002-11-01

    We present a first design of an unmanned aerial vehicle whose aerodynamic loads are carried by comb-like permeable surfaces. This concept was based on observation and analysis of the flight capabilities of the Thrip family of insects, whose have wings of this form and various plant seeds which use this concept to form an aerodynamic decelerator. This concept is only practical for at low Reynolds numbers, as the viscous trace of bodies moving in fluid becomes thicker as Re becomes smaller. When Re<1, a cylinder moving in fluid can drag along fluid up to several cylinder diameters. This drag effect can be used to produce a comb structure, where the ratio of comb rod to inter-rod distance can be up to 0.1 without significant throughflow, i.e. the comb is equivalent to a continuous surface. To demonstrate this principle, we have built artificial ``dandelion seeds", i.e. stable aerodynamic decelerators (parachutes) made of permeable light mats of submicron diameter nanofibers. We produced the nanofiber matrices (mats) by electrospinning of polymer solutions, obtaining fibers of 200-400 nm diameter. These fibers were then deposited on frames that serve to define the aerodynamic surfaces, thus producing the mat, with controllable density. For stability, the aerodynamic surfaces had positive dihedral ( inverted umbrella) forms with the fuselage hanging below. When dropped, the platforms fell freely through the air, apex down, reaching terminal velocity very quickly. By comparing the sink rate of the permeable structures with equivalent decelerators with continuous (Saran-wrap) surfaces we show that the permeable surfaces are equivalent to continuous surfaces, with significant weight savings, as long as the local Reynolds number is o(1).

  16. Fatigue performance of joints executed in pure titanium structures with several diameters.

    PubMed

    Nuñez-Pantoja, Juliana Maria Costa; Vaz, Luis Geraldo; Nóbilo, Mauro Antônio de Arruda; Mesquita, Marcelo Ferraz

    2011-01-01

    This study evaluated fatigue strength of CP-Ti laser-welded joints. Sixty (20/diameter) CP-Ti casted dumbbell rods with diameters of 1.5, 2.0, and 3.5 mm were sectioned and welded using two joint openings (0.0 (00) and 0.6 mm (06)). Six groups were formed, amounting to a total of 9 (n=10) with inclusion of intact groups. Welding was executed using 360 V/8 ms (1.5 and 2.0 mm) and 380 V/9 ms (3.5 mm). Joints were finished, polished, and submitted to radiographic examination to visually analyze presence of porosity (PP). Specimens were submitted to cyclic tests, and the number of cycles until failure (NC) was recorded. Fractured surfaces were examined by SEM. Kruskal-Wallis and Dunn (α=0.05) tests demonstrated that NC was lower for all diameters with 06, and for 3.5 mm/00. NC and PP were found to have a negative correlation (Spearman Coefficient). For CP-Ti frameworks with thin diameters, laser welding is better when structures are juxtaposed. PMID:22123013

  17. Is There a Benefit to Head Size Greater Than 36 mm in Total Hip Arthroplasty?

    PubMed

    Haughom, Bryan D; Plummer, Darren R; Moric, Mario; Della Valle, Craig J

    2016-01-01

    This study compares the rate of dislocation and revision for instability between 36-mm and anatomic femoral heads (large diameter metal-on-metal THA, dual-mobility bearings, and hip resurfacing arthroplasty) in patients at high risk for dislocation. A total of 501 high-risk patients, over a 10-year period, were identified (282 36-mm THA, 24 dual-mobility bearings, 83 metal-on-metal arthroplasty, and 112 hip resurfacing arthroplasty). There were 13 dislocations in the 36-mm group compared to 1 in the anatomic group (4.6% vs 0.5%; P = .005). Four patients dislocated more than once in the 36-mm group (1.4% vs 0%; P = .04), and 2 patients in the 36-mm group required a revision for instability (0.7% vs 0%; P = .11). These results suggest that anatomic head sizes significantly lower the risk of dislocation in high-risk patients. PMID:26360768

  18. Performance of and Pressure Elevation Formed by Small-diameter Microtubes Used in Constant-flow Sets

    PubMed Central

    Sohn, Sae Woon; Noh, Myounggyu D.; Lee, Jong-Hyun; Kim, Kyoung Nam; Ahn, Byung Heon

    2016-01-01

    Purpose We explored the performance of and pressure elevation caused by small-diameter microtubes used to reduce overfiltration. Methods Using a syringe pump-driven constant-flow setting (2 µL/min), pressures were measured for polytetrafluoroethylene (PTFE) microtubes 5 mm in length with inner diameters of 51, 64, and 76 µm and for polyether block amide (PEBAX) microtubes with an inner diameter of 76 µm. Experiments (using microtubes only) were initially performed in air, water, and enucleated pig eyes and were repeated under the same conditions using intraluminal 9/0 nylon stents. Results The pressures measured in air in 51-, 64-, and 76-µm-diameter PTFE microtubes differed significantly (22.1, 16.9, and 12.2 mmHg, respectively; p < 0.001), and that of the 76-µm-diameter PEBAX microtube was 15.8 mmHg (p < 0.001 compared to the 12.2 mmHg of the 76-µm-diameter PTFE microtube). The pressures measured in water also differed significantly among the three microtubes at 3.9, 3.0, and 1.4 mmHg, respectively, while that in the PEBAX microtube was 2.6 mmHg (all p < 0.001). Using the intraluminal stent, the pressure in water of the three different PTFE microtubes increased to 22.6, 18.0, and 4.1 mmHg, respectively, and that in the PEBAX microtube increased to 10.5 mmHg (all p < 0.001). Similar trends were evident when measurements were performed in pig eyes. Conclusions Although microtubes of smaller diameter experienced higher pressure in air, reduction of the inner diameter to 51 µm did not adequately increase the pressure attained in water or pig eyes. Insertion of an intraluminal stent effectively elevated the latter pressures. PEBAX microtubes created higher pressures than did PTFE microtubes. PMID:27247522

  19. Modular Small Diameter Vascular Grafts with Bioactive Functionalities

    PubMed Central

    Neufurth, Meik; Wang, Xiaohong; Tolba, Emad; Dorweiler, Bernhard; Schröder, Heinz C.; Link, Thorben; Diehl-Seifert, Bärbel; Müller, Werner E. G.

    2015-01-01

    We report the fabrication of a novel type of artificial small diameter blood vessels, termed biomimetic tissue-engineered blood vessels (bTEBV), with a modular composition. They are composed of a hydrogel scaffold consisting of two negatively charged natural polymers, alginate and a modified chitosan, N,O-carboxymethyl chitosan (N,O-CMC). Into this biologically inert scaffold two biofunctionally active biopolymers are embedded, inorganic polyphosphate (polyP) and silica, as well as gelatin which exposes the cell recognition signal, Arg-Gly-Asp (RGD). These materials can be hardened by exposure to Ca2+ through formation of Ca2+ bridges between the polyanions, alginate, N,O-CMC, and polyP (alginate-Ca2+-N,O-CMC-polyP). The bTEBV are formed by pressing the hydrogel through an extruder into a hardening solution, containing Ca2+. In this universal scaffold of the bTEBV biomaterial, polycations such as poly(l-Lys), poly(d-Lys) or a His/Gly-tagged RGD peptide (three RGD units) were incorporated, which promote the adhesion of endothelial cells to the vessel surface. The mechanical properties of the biopolymer material (alginate-Ca2+-N,O-CMC-polyP-silica) revealed a hardness (elastic modulus) of 475 kPa even after a short incubation period in CaCl2 solution. The material of the artificial vascular grafts (bTEBVs with an outer size 6 mm and 1.8 mm, and an inner diameter 4 mm and 0.8 mm, respectively) turned out to be durable in 4-week pulsatile flow experiments at an alternating pressure between 25 and 100 mbar (18.7 and 75.0 mm Hg). The burst pressure of the larger (smaller) vessels was 850 mbar (145 mbar). Incorporation of polycationic poly(l-Lys), poly(d-Lys), and especially the His/Gly-tagged RGD peptide, markedly increased the adhesion of human, umbilical vein/vascular endothelial cells, EA.HY926 cells, to the surface of the hydrogel. No significant effect of the polyP samples on the clotting of human plasma is measured. We propose that the metabolically degradable

  20. SINGLE LOOP - MULTI GAP RESONATOR FOR WHOLE BODY EPR IMAGING OF MICE AT 1.2 GHZ

    PubMed Central

    Petryakov, Sergey; Samouilov, Alexandre; Kesselring, Eric; Wasowicz, Tomasz; Caia, George L.; Zweier, Jay L.

    2009-01-01

    For whole body EPR imaging of small animals, typically low frequencies of 250–750 MHz have been used due to the microwave losses at higher frequencies and the challenges in designing suitable resonators to accommodate these large lossy samples. However, low microwave frequency limits the obtainable sensitivity. L-band frequencies can provide higher sensitivity, and have been commonly used for localized in vivo EPR spectroscopy. Therefore, it would be highly desirable to develop an L-band microwave resonator suitable for in vivo whole body EPR imaging of small animals such as living mice. A 1.2 GHz 16 gap resonator with inner diameter of 43 mm and 48 mm length was designed and constructed for whole body EPR imaging of small animals. The resonator has good field homogeneity and stability to animal induced motional noise. Resonator stability was achieved with electrical and mechanical design utilizing a fixed position double coupling loop of novel geometry, thus minimizing the number of moving parts. Using this resonator, high quality EPR images of lossy phantoms and living mice were obtained. This design provides good sensitivity, ease of sample access, excellent stability and uniform B1 field homogeneity for in vivo whole body EPR imaging of mice at 1.2 GHz. PMID:17625940

  1. DiameterJ: A validated open source nanofiber diameter measurement tool.

    PubMed

    Hotaling, Nathan A; Bharti, Kapil; Kriel, Haydn; Simon, Carl G

    2015-08-01

    Despite the growing use of nanofiber scaffolds for tissue engineering applications, there is not a validated, readily available, free solution for rapid, automated analysis of nanofiber diameter from scanning electron microscope (SEM) micrographs. Thus, the goal of this study was to create a user friendly ImageJ/FIJI plugin that would analyze SEM micrographs of nanofibers to determine nanofiber diameter on a desktop computer within 60 s. Additional design goals included 1) compatibility with a variety of existing segmentation algorithms, and 2) an open source code to enable further improvement of the plugin. Using existing algorithms for centerline determination, Euclidean distance transforms and a novel pixel transformation technique, a plugin called "DiameterJ" was created for ImageJ/FIJI. The plugin was validated using 1) digital synthetic images of white lines on a black background and 2) SEM images of nominally monodispersed steel wires of known diameters. DiameterJ analyzed SEM micrographs in 20 s, produced diameters not statistically different from known values, was over 10-times closer to known diameter values than other open source software, provided hundreds of times the sampling of manual measurement, and was hundreds of times faster than manual assessment of nanofiber diameter. DiameterJ enables users to rapidly and thoroughly determine the structural features of nanofiber scaffolds and could potentially allow new insights to be formed into fiber diameter distribution and cell response. PMID:26043061

  2. Submicron diameter single crystal sapphire optical fiber

    SciTech Connect

    Hill, Cary; Homa, Daniel; Liu, Bo; Yu, Zhihao; Wang, Anbo; Pickrell, Gary

    2014-10-02

    In this work, a submicron-diameter single crystal sapphire optical fiber was demonstrated via wet acid etching at elevated temperatures. Etch rates on the order 2.3 µm/hr were achievable with a 3:1 molar ratio sulfuric-phosphoric acid solution maintained at a temperature of 343°C. A sapphire fiber with an approximate diameter of 800 nm was successfully fabricated from a commercially available fiber with an original diameter of 50 µm. The simple and controllable etching technique provides a feasible approach to the fabrication of unique waveguide structures via traditional silica masking techniques. The ability to tailor the geometry of sapphire optical fibers is the first step in achieving optical and sensing performance on par with its fused silica counterpart.

  3. Large diameter astromast development, phase 1

    NASA Technical Reports Server (NTRS)

    Preiswerk, P. R.; Finley, L. A.; Knapp, K.

    1983-01-01

    Coilable-longeron lattice columns called Astromasts (trademark) were manufactured for a variety of spacecraft missions. These flight structures varied in diameter from 0.2 to 0.5 meter (9 to 19 in.), and the longest Astromast of this type deploys to a length of 30 meters (100 feet). A double-laced diagonal Astromast design referred to as the Supermast (trademark) which, because it has shorter baylengths than an Astromast, is approximately four times as strong. The longeron cross section and composite material selection for these structures are limited by the maximum strain associated with stowage and deployment. As a result, future requirements for deployable columns with high stiffness and strength require the development of both structures in larger diameters. The design, development, and manufacture of a 6.1-m-long (20-ft), 0.75-m-diameter (30-in.), double-laced diagonal version of the Astromast is described.

  4. Submicron diameter single crystal sapphire optical fiber

    DOE PAGESBeta

    Hill, Cary; Homa, Daniel; Liu, Bo; Yu, Zhihao; Wang, Anbo; Pickrell, Gary

    2014-10-02

    In this work, a submicron-diameter single crystal sapphire optical fiber was demonstrated via wet acid etching at elevated temperatures. Etch rates on the order 2.3 µm/hr were achievable with a 3:1 molar ratio sulfuric-phosphoric acid solution maintained at a temperature of 343°C. A sapphire fiber with an approximate diameter of 800 nm was successfully fabricated from a commercially available fiber with an original diameter of 50 µm. The simple and controllable etching technique provides a feasible approach to the fabrication of unique waveguide structures via traditional silica masking techniques. The ability to tailor the geometry of sapphire optical fibers ismore » the first step in achieving optical and sensing performance on par with its fused silica counterpart.« less

  5. NWA 7034 Martian breccia: Ar/Ar ages of ca. 1.2 to 1.4 Ga

    NASA Astrophysics Data System (ADS)

    Cohen, B. E.; Mark, D. F.; Cassata, W.; Lee, M. R.; Smith, C. L.

    2015-12-01

    NWA 7034 and its paired stones are some of the oldest and most diverse of the Martian meteorites. They are complex polymict breccias of impact, igneous, and sedimentary clasts set in a dark grey matrix [1; 2]. The rock also contains angular mineral fragments, including K-feldspar, plagioclase feldspar, and pyroxene [1; 2]. Mineral fragments are often > 1 mm wide, and clasts can be > 1 cm. This diverse breccia assemblage indicates formation via repeated impact events, supported by Rb-Sr, Sm-Nd and U-Pb ages ranging from 1.3 to 4.4 Ga [1, 2, and references therein]. In this study we investigate the distribution of ages yielded by Ar/Ar, with nine aliquots analyzed to date, and additional analyses planned. In order to analyze only single phases, chips of matrix/clasts were restricted to visibly monomict fragments < 1 mm diameter, while mineral separates were analyzed as single crystals. Cosmogenic Ar corrections are from [3]. Analyses were undertaken at SUERC and Lawrence Livermore National Laboratory, and the results pooled. The bulk of aliquots (n = 8) yielded ages of ca. 1.2-1.4 Ga indicating a major thermal event occurred at around the same time as crystallization of the Nakhlite group of meteorites. Select step ages are considerably older (> 2 Ga), supporting results of other chronometers that much older material is present in this sample. These results also demonstrate that some older fragments retained Ar during breccia formation. [1] Wittmann A. et al. (2015) Meteoritics & Planet. Sci., 50, 326-352. [2] Santos A. R. et al. (2015) GCA, 157, 56-85. [3] Cassata W. S., and Borg L. E. (2015) 46th LPSC, Abstract #2742.

  6. THERMAL EVALUATION OF DIFFERENT DRIFT DIAMETER SIZES

    SciTech Connect

    H.M. Wade

    1999-01-04

    The purpose of this calculation is to estimate the thermal response of a repository-emplaced waste package and its corresponding drift wall surface temperature with different drift diameters. The case examined is that of a 21 pressurized water reactor (PWR) uncanistered fuel (UCF) waste package loaded with design basis spent nuclear fuel assemblies. This calculation evaluates a 3.5 meter to 6.5 meter drift diameter range in increments of 1.0 meters. The time-dependent temperatures of interest, as determined by this calculation, are the spent nuclear fuel cladding temperature, the waste package surface temperature, and the drift wall surface temperature.

  7. Shaft Diameter Measurement Using Structured Light Vision

    PubMed Central

    Liu, Siyuan; Tan, Qingchang; Zhang, Yachao

    2015-01-01

    A method for measuring shaft diameters is presented using structured light vision measurement. After calibrating a model of the structured light measurement, a virtual plane is established perpendicular to the measured shaft axis and the image of the light stripe on the shaft is projected to the virtual plane. On the virtual plane, the center of the measured shaft is determined by fitting the projected image under the geometrical constraints of the light stripe, and the shaft diameter is measured by the determined center and the projected image. Experiments evaluated the measuring accuracy of the method and the effects of some factors on the measurement are analyzed. PMID:26274963

  8. Fabrication of 10nm diameter carbon nanopores

    SciTech Connect

    Radenovic, Aleksandra; Trepagnier, Eliane; Csencsits, Roseann; Downing, Kenneth H; Liphardt, Jan

    2008-09-25

    The addition of carbon to samples, during imaging, presents a barrier to accurate TEM analysis, the controlled deposition of hydrocarbons by a focused electron beam can be a useful technique for local nanometer-scale sculpting of material. Here we use hydrocarbon deposition to form nanopores from larger focused ion beam (FIB) holes in silicon nitride membranes. Using this method, we close 100-200nm diameter holes to diameters of 10nm and below, with deposition rates of 0.6nm per minute. I-V characteristics of electrolytic flow through these nanopores agree quantitatively with a one dimensional model at all examined salt concentrations.

  9. Rotman lens for mm-wavelengths

    NASA Astrophysics Data System (ADS)

    Hall, Leonard T.; Hansen, Hedley J.; Abbott, Derek

    2002-11-01

    The 77 GHz band has been reserved for intelligent cruise control in luxury cars and some public transport services in America and the United Kingdom. The Rotman lens offers a cheap and compact means to extend the single beam systems generally used, to fully functional beam staring arrangements. Rotman lenses have been built for microwave frequencies with limited success. The flexibility of microstrip transmission lines and the advent of fast accurate simulation packages allow practical Rotman lenses to be designed at mm-wavelengths. This paper discusses the limitations of the conventional design approach and predicts the performance of a new Rotman lens designed at 77 GHz.

  10. Optical receivers with large-diameter photodiode

    NASA Astrophysics Data System (ADS)

    Swoboda, Robert; Schneider, Kerstin; Zimmermann, Horst

    2006-04-01

    This work presents two types of optical receivers with large-diameter photodiodes. Both are optoelectronic integrated circuits (OEICs) realized in 0.6μm BiCMOS Si technology integrating PIN photodiode, transimpedance amplifier (TIA) and output circuit on chip. The two circuits are an optocoupler with a photodiode diameter of 780μm and a rise- and falltime of 5ns and 4.9ns respectively at 850nm light and a plastic optical fiber (POF) receiver with a photodiode diameter of 500μm and upper -3dB cut-off frequencies of 165MHz at 660nm light and 148MHz at 850nm light. The measured rise- and falltime of the POF receiver was 1.78ns and 2.45ns at 660nm light and 1.94ns and 2.5ns at 850ns, respectively. The presented results combine the advantage of easier handling of large-diameter photodiode receivers and high performance.

  11. Changing the Diameter of a Viewing Tube

    ERIC Educational Resources Information Center

    Obara, Samuel

    2009-01-01

    This article is about the students' investigation about the relationship between the diameter of the view tubes (x) of constant lengths and the viewable vertical distance (y) on the wall while keeping the perpendicular distance from the eyeball to the wall constant. The students collected data and used and represented it in tabular and graphical…

  12. Small diameter symmetric networks from linear groups

    NASA Technical Reports Server (NTRS)

    Campbell, Lowell; Carlsson, Gunnar E.; Dinneen, Michael J.; Faber, Vance; Fellows, Michael R.; Langston, Michael A.; Moore, James W.; Multihaupt, Andrew P.; Sexton, Harlan B.

    1992-01-01

    In this note is reported a collection of constructions of symmetric networks that provide the largest known values for the number of nodes that can be placed in a network of a given degree and diameter. Some of the constructions are in the range of current potential engineering significance. The constructions are Cayley graphs of linear groups obtained by experimental computation.

  13. Reducing the diameters of computer networks

    NASA Technical Reports Server (NTRS)

    Bokhari, S. H.; Raza, A. D.

    1986-01-01

    Three methods of reducing the diameters of computer networks by adding additional processor to processor links under the constraint that no more than one I/O port be added to each processor are discussed. This is equivalent to adding edges to a given graph under the constraint that the degree of any node be increased, at most, by one.

  14. Computing Minimum Diameter Color-Spanning Sets

    NASA Astrophysics Data System (ADS)

    Fleischer, Rudolf; Xu, Xiaoming

    We study the minimum diameter color-spanning set problem which has recently drawn some attention in the database community. We show that the problem can be solved in polynomial time for L 1 and L ∞ metrics, while it is NP-hard for all other L p metrics even in two dimensions. However, we can efficiently compute a constant factor approximation.

  15. 7 CFR 51.320 - Diameter.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to a line from stem to blossom end. When measuring for maximum size, “diameter” means the smallest dimension of the apple determined...

  16. 7 CFR 51.320 - Diameter.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to... dimension of the apple determined by passing the apple through a round opening in any position....

  17. 7 CFR 51.320 - Diameter.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ..., CERTIFICATION, AND STANDARDS) United States Standards for Grades of Apples Definitions § 51.320 Diameter. When measuring for minimum size, “diameter” means the greatest dimension of the apple measured at right angles to... dimension of the apple determined by passing the apple through a round opening in any position....

  18. Mimicking Form and Function of Native Small Diameter Vascular Conduits Using Mulberry and Non-mulberry Patterned Silk Films.

    PubMed

    Gupta, Prerak; Kumar, Manishekhar; Bhardwaj, Nandana; Kumar, Jadi Praveen; Krishnamurthy, C S; Nandi, Samit Kumar; Mandal, Biman B

    2016-06-29

    Autologous graft replacement as a strategy to treat diseased peripheral small diameter (≤6 mm) blood vessel is often challenged by prior vein harvesting. To address this issue, we fabricated native-tissue mimicking multilayered small diameter vascular graft (SDVG) using mulberry (Bombyx mori) and Indian endemic non-mulberry (Antheraea assama and Philosamia ricini) silk. Patterned silk films were fabricated on microgrooved PDMS mold, casted by soft lithography. The biodegradable patterned film templates with aligned cell sheets were rolled onto an inert mandrel to mimic vascular conduit. The hemocompatible and mechanically strong non-mulberry films with RGD motif supported ∼1.2 folds greater proliferation of vascular cells with aligned anchorage. Elicitation of minimal immune response on subcutaneous implantation of the films in mice was complemented by ∼45% lower TNF α secretion by in vitro macrophage culture post 7 days. Pattern-induced alignment favored the functional contractile phenotype of smooth muscle cells (SMCs), expressing the signature markers-calponin, α-smooth muscle actin (α-SMA), and smooth muscle myosin heavy chain (SM-MHC). Endothelial cells (ECs) exhibited a typical punctuated pattern of von Willebrand factor (vWF). Deposition of collagen and elastin by the SMCs substantiated the aptness of the graft with desired biomechanical attributes. Furthermore, the burst strength of the fabricated conduit was in the range of ∼915-1260 mmHg, a prerequisite to withstand physiological pressure. This novel fabrication approach may eliminate the need of maturation in a pulsatile bioreactor for obtaining functional cellular phenotype. This work is thereby an attestation to the immense prospects of exploring non-mulberry silk for bioengineering a multilayered vascular conduit similar to a native vessel in "form and function", befitting for in vivo transplantation. PMID:27269821

  19. Photoelastic Stress Analysis in Prosthetic Implants of Different Diameters: Mini, Narrow, Standard or Wide

    PubMed Central

    Pesqueira, Alves Aldiéris; Santos, Daniela Micheline Dos; Haddad, Marcela Filié; Moreno, Amália

    2014-01-01

    Purpose: This study investigated the biomechanical behavior of screwed partial fixed prosthesis supported by implants with different diameters (2.5 mm; 3.3 mm and 3.75 mm) by using a photoelastic analysis. Materials and Methods: Six photoelastic models were fabricated in PL-2 resin as single crowns or splinted 3-unit piece. Models were positioned in a circular polariscope and 100-N axial and oblique (45 degrees) loads were applied in the occlusal surface of the crowns by using a universal testing machine (EMIC). The stresses were photographically recorded and qualitatively analyzed using a software (Adobe Photoshop). Results: Under axial loading, the number of fringes was inversely proportional to the diameter of the implants in the single crown models. In the splinted 3-unit piece, the 3.75-mm implant promoted lower number of fringes regardless of loading area application. Under oblique loading, a slight increase of fringes number was observed for all groups. Conclusion: The standard implant diameter promoted better stress distribution than the narrow and mini diameter implants. Additionally, the splinted crowns showed a more uniform stress distribution. PMID:25386531

  20. Prediction of Stereochemistry using Q2MM.

    PubMed

    Hansen, Eric; Rosales, Anthony R; Tutkowski, Brandon; Norrby, Per-Ola; Wiest, Olaf

    2016-05-17

    The standard method of screening ligands for selectivity in asymmetric, transition metal-catalyzed reactions requires experimental testing of hundreds of ligands from ligand libraries. This "trial and error" process is costly in terms of time as well as resources and, in general, is scientifically and intellectually unsatisfying as it reveals little about the underlying mechanism behind the selectivity. The accurate computational prediction of stereoselectivity in enantioselective catalysis requires adequate conformational sampling of the selectivity-determining transition state but has to be fast enough to compete with experimental screening techniques to be useful for the synthetic chemist. Although electronic structure calculations are accurate and general, they are too slow to allow for sampling or fast screening of ligand libraries. The combined requirements can be fulfilled by using appropriately fitted transition state force fields (TSFFs) that represent the transition state as a minimum and allow fast conformational sampling using Monte Carlo. Quantum-guided molecular mechanics (Q2MM) is an automated force field parametrization method that generates accurate, reaction-specific TSFFs by fitting the functional form of an arbitrary force field using only electronic structure calculations by minimization of an objective function. A key feature that distinguishes the Q2MM method from many other automated parametrization procedures is the use of the Hessian matrix in addition to geometric parameters and relative energies. This alleviates the known problems of overfitting of TSFFs. After validation of the TSFF by comparison to electronic structure results for a test set and available experimental data, the stereoselectivity of a reaction can be calculated by summation over the Boltzman-averaged relative energies of the conformations leading to the different stereoisomers. The Q2MM method has been applied successfully to perform virtual ligand screens on a range of

  1. The new 800mm reflecting telescope

    NASA Astrophysics Data System (ADS)

    Teske, Hans-Joachim

    The design and capabilities of the 800-mm Ritchey-Chretien system are described. The optical system of the telescope has an aperture ratio of 1:8; is suitable for photography in a 1.5 deg field with photoplates of 16 x 16 cm; and consists of primary and secondary hyperbolically deformed mirrors. The attachment of the mirrors, position rotator, and offset guider to the tube, which is a truss structure, is examined. The mount for the telescope is an equatorial fork type. The electronic control system is a 16-bit microcomputer system; the functions of the control system are discussed. The 8-m polyester dome of the telescope consists of a supporting steel structure carrying shell elements of glass fiber-reinforced polyester resins. Consideration is given to the auxiliary devices of the telescope.

  2. Prediction of Stereochemistry using Q2MM

    PubMed Central

    2016-01-01

    Conspectus The standard method of screening ligands for selectivity in asymmetric, transition metal-catalyzed reactions requires experimental testing of hundreds of ligands from ligand libraries. This “trial and error” process is costly in terms of time as well as resources and, in general, is scientifically and intellectually unsatisfying as it reveals little about the underlying mechanism behind the selectivity. The accurate computational prediction of stereoselectivity in enantioselective catalysis requires adequate conformational sampling of the selectivity-determining transition state but has to be fast enough to compete with experimental screening techniques to be useful for the synthetic chemist. Although electronic structure calculations are accurate and general, they are too slow to allow for sampling or fast screening of ligand libraries. The combined requirements can be fulfilled by using appropriately fitted transition state force fields (TSFFs) that represent the transition state as a minimum and allow fast conformational sampling using Monte Carlo. Quantum-guided molecular mechanics (Q2MM) is an automated force field parametrization method that generates accurate, reaction-specific TSFFs by fitting the functional form of an arbitrary force field using only electronic structure calculations by minimization of an objective function. A key feature that distinguishes the Q2MM method from many other automated parametrization procedures is the use of the Hessian matrix in addition to geometric parameters and relative energies. This alleviates the known problems of overfitting of TSFFs. After validation of the TSFF by comparison to electronic structure results for a test set and available experimental data, the stereoselectivity of a reaction can be calculated by summation over the Boltzman-averaged relative energies of the conformations leading to the different stereoisomers. The Q2MM method has been applied successfully to perform virtual ligand

  3. mm-wave solid state amplifiers

    NASA Astrophysics Data System (ADS)

    Wolfert, P. H.; Crowley, J. D.; Fank, F. B.

    The development of mm-wave amplifiers using InP Gunn diodes is reviewed including a low-noise eight-stage amplifier for replacement of a Ka-band TWTA and a three-stage amplifier for the 42.5 to 44.5 range with an output power of 100 mW and 20 dB associated gain. A detailed description of a three-stage amplifier for the 54 to 58 GHz range is given with 100 mW output power and 15 dB associated gain, a small signal gain of 30 dB and an N.F. of 15.5 to 16.5 dB. The design of a broad band, low-loss V-band circulator, which was used in the amplifier, is described.

  4. Experimental study of lean flammability limits of methane/hydrogen/air mixtures in tubes of different diameters

    SciTech Connect

    Shoshin, Y.L.; Goey, L.P.H. de

    2010-04-15

    Lean limit flames in methane/hydrogen/air mixtures propagating in tubes of internal diameters (ID) of 6.0, 8.9, 12.3, 18.4, 25.2, 35.0, and 50.2 mm have been experimentally studied. The flames propagated upward from the open bottom end of the tube to the closed upper end. The content of hydrogen in the fuel gas has been varied in the range 0-40 mol%. Lean flammability limits have been determined; flame shapes recorded and the visible speed of flame propagation measured. Most of the observed limit flames in tubes with diameters in the range of 8.9-18.4 mm had enclosed shape, and could be characterized as distorted or spherical flame balls. The tendency was observed for mixtures with higher hydrogen content to form smaller size, more uniform flame balls in a wider range of tube diameters. At hydrogen content of 20% or more in the fuel gas, limit flames in largest diameters (35.0 mm and 50.2 mm ID) tubes had small, compared to the tube diameter, size and were ''lens''-shaped. ''Regular'' open-front lean limit flames were observed only for the smallest diameters (6.0 mm and 8.9 mm) and largest diameters (35.0 and 50.2 mm ID), and only for methane/air and (90% CH{sub 4} + 10% H{sub 2})/air mixtures, except for 6 mm ID tube in which all limit flames had open front. In all experiments, except for the lean limit flames in methane/air and (90% CH{sub 4} + 10% H{sub 2})/air mixtures in the 8.9 mm ID tube, and all limit flames in 6.0 mm ID tube, visible flame speeds very weakly depended on the hydrogen content in the fuel gas and were close to- or below the theoretical estimate of the speed of a rising hot bubble. This observation suggests that the buoyancy is the major factor which determines the visible flame speed for studied limit flames, except that last mentioned. A decrease of the lean flammability limit value with decreasing the tube diameter was observed for methane/air and (90% CH{sub 4} + 10% H{sub 2})/air mixtures for tubes having internal diameters in the range

  5. Preparation and evaluation of bicomponent and homogeneous polyester silk small diameter arterial prostheses.

    PubMed

    Yang, Xiaoyuan; Wang, Lu; Guan, Guoping; King, Martin W; Li, Yuling; Peng, Lei; Guan, Ying; Hu, Xingyou

    2014-01-01

    The development of a small diameter (≤5 mm) arterial prosthesis requires the appropriate selection of materials, structure and fabrication method so as to provide adequate mechanical properties, superior biocompatibility and precise control over the diameter. In this study, 100% polyester, 100% silk fibroin and a combination of both yarns were woven into seamless tubular prototype prostheses with different basic weaves. After degumming/scouring they met a target inner diameter of 3.9±0.3 mm which demonstrates that weaving is a precise way to manufacture small caliber arterial prostheses. In conclusion, the bicomponent polyester/silk woven samples had superior mechanical properties and improved cytocompatibility compared to commercial ePTFE devices. PMID:23292721

  6. Effect of Antenna Diameter on the Characteristics of Internal-Type Linear Inductively Coupled Plasma

    NASA Astrophysics Data System (ADS)

    Hyeuk Lim, Jong; Kim, Kyong Nam; Gweon, Gwang Ho; Hong, Seung Pyo; Yeom, Geun Young

    2009-09-01

    In this study, the antenna characteristics of an internal-type, linear, inductively coupled plasma (ICP) source were varied by changing the inner conductor diameter of the ICP antenna composed of an inner conductor enclosed by outer dielectric tubing. The effect of the varied antenna characteristics on the plasma characteristics and the electrical characteristics of the large area plasma source with a substrate area of 2300×2000 mm2 were investigated. The decrease of the antenna conductor diameter from 25 to 10 mm decreased the capacitance of the antenna between the conductor and the dielectric tubing, increased the plasma density, decreased the plasma potential at the same rf power, and improved the plasma uniformity. The increased plasma density and the decreased plasma potential obtained with the smaller antenna conductor diameter were attributed to the increased power transfer efficiency caused by the increased inductive coupling at the same rf power.

  7. Effect of Antenna Diameter on the Characteristics of Internal-Type Linear Inductively Coupled Plasma

    NASA Astrophysics Data System (ADS)

    Lim, Jong Hyeuk; Kim, Kyong Nam; Gweon, Gwang Ho; Hong, Seung Pyo; Yeom, Geun Young

    2009-09-01

    In this study, the antenna characteristics of an internal-type, linear, inductively coupled plasma (ICP) source were varied by changing the inner conductor diameter of the ICP antenna composed of an inner conductor enclosed by outer dielectric tubing. The effect of the varied antenna characteristics on the plasma characteristics and the electrical characteristics of the large area plasma source with a substrate area of 2300× 2000 mm2 were investigated. The decrease of the antenna conductor diameter from 25 to 10 mm decreased the capacitance of the antenna between the conductor and the dielectric tubing, increased the plasma density, decreased the plasma potential at the same rf power, and improved the plasma uniformity. The increased plasma density and the decreased plasma potential obtained with the smaller antenna conductor diameter were attributed to the increased power transfer efficiency caused by the increased inductive coupling at the same rf power.

  8. A comparative study on liquid core formulation on the diameter on the alginate capsules

    NASA Astrophysics Data System (ADS)

    Ong, Hui-Yen; Lee, Boon-Beng; Radzi, AkmalHadi Ma'; Zakaria, Zarina; Chan, Eng-Seng

    2015-08-01

    Liquid core capsule has vast application in biotechnology related industries such as pharmaceutical, medical, agriculture and food. Formulation of different types of capsule was important to determine the performance of the capsule. Generally, the liquid core capsule with different formulations generated different size of capsule.Therefore, the aim of this project is to investigate the effect of different liquid core solution formulations on the diameter of capsule. The capsule produced by extruding liquid core solutions into sodium alginate solution. Three types of liquid core solutions (chitosan, xanthan gum, polyethylene glycol (PEG)) were investigated. The results showed that there is significant change in capsule diameter despite in different types of liquid core solution were used and a series of capsule range in diameter of 3.1 mm to 4.5 mm were produced. Alginate capsule with chitosan formulation appeared to be the largest capsule among all.

  9. Biomechanical optimization of the diameter of distraction screw in distraction implant by three-dimensional finite element analysis.

    PubMed

    Lu, Songhe; Li, Tao; Zhang, Yongqiang; Lu, Chunlei; Sun, Yingying; Zhang, Junrui; Xu, Dezhong

    2013-11-01

    Three-dimensional (3D) finite element models of a posterior mandibular segment and a distraction implant (DI) were created and assembled in this study. The diameter of distraction screw (DS) was set as input variable, ranging from 1.0 to 3.0mm, to analyze the stress and displacement, in order to obtain an optimal outcome of the DI. The results indicate that when the diameter of DS was 2.0mm, the stresses in jaw bone and DS and the displacement of DS reached a relatively low range. The diameter of DS significantly affects the stress distribution in DI and surrounding bone. The present study demonstrates that from clinical and biomechanical points of view, the optimal diameter of DS is 2.0mm. PMID:24209940

  10. 76 FR 7815 - Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure Pipe (Over 41/2

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-02-11

    ... Antidumping and Countervailing Duty Administrative Reviews and Requests for Revocations in Part, 75 FR 44224... International Trade Administration Certain Large Diameter Carbon and Alloy Seamless Standard, Line, and Pressure... certain large diameter carbon and alloy seamless standard, line, and pressure pipe (over 4\\1/2\\...

  11. Coke from small-diameter tubes analyzed

    SciTech Connect

    Albright, L.F.

    1988-08-29

    The mechanism for coke deposit formation and the nature of the coke itself can vary with the design of the ethylene furnace tube bank. In this article, coke deposits from furnaces with small-diameter pyrolysis tubes are examined. The samples were taken from four furnaces of identical design (Plant B). As in both the first and second installments of the series, the coke deposits were examined using a scanning electron microscope (SEM) and an energy dispersive X-ray analyzer (EDAX). The deposits from the small-diameter tubes are compared with the coke deposits from the furnace discussed in earlier articles. Analysis of the coke in both sets of samples are then used to offer recommendations for improved decoking procedures, operating procedures, better feed selection, and better selection of the metallurgy used in furnace tubes, to extend the operating time of the furnace tubes by reducing the amount and type of coke build up.

  12. Small diameter, deep bore optical inspection system

    DOEpatents

    Lord, David E.; Petrini, Richard R.; Carter, Gary W.

    1981-01-01

    An improved rod optic system for inspecting small diameter, deep bores. The system consists of a rod optic system utilizing a curved mirror at the end of the rod lens such that the optical path through the system is bent 90.degree. to minimize optical distortion in examining the sides of a curved bore. The system is particularly useful in the examination of small bores for corrosion, and is capable of examining 1/16 inch diameter and up to 4 inch deep drill holes, for example. The positioning of the curved mirror allows simultaneous viewing from shallow and right angle points of observation of the same artifact (such as corrosion) in the bore hole. The improved rod optic system may be used for direct eye sighting, or in combination with a still camera or a low-light television monitor; particularly low-light color television.

  13. Small diameter, deep bore optical inspection system

    DOEpatents

    Lord, D.E.; Petrini, R.R.; Carter, G.W.

    An improved rod optic system for inspecting small diameter, deep bores is described. The system consists of a rod optic system utilizing a curved mirror at the end of the rod lens such that the optical path through the system is bent 90/sup 0/ to minimize optical distortion in examing the sides of a curved bore. The system is particularly useful in the examination of small bores for corrosion, and is capable if examing 1/16 inch diameter and up to 4-inch deep drill holes, for example. The positioning of the curved mirror allows simultaneous viewing from shallow and righ angle points of observation of the same artifact (such as corrosion) in the bore hole. The improved rod optic system may be used for direct eye sighting, or in combination with a still camera or a low-light television monitor; particularly low-light color television.

  14. European Projects of Solar Diameter Monitoring

    NASA Astrophysics Data System (ADS)

    Sigismondi, Costantino; Bianda, Michele; Arnaud, Jean

    2008-10-01

    Three projects dealing with solar diameter evolution are presently in development. Historical and contemporary eclipses and planetary transits data collection and analysis, to cover potentially the last 5 centuries with an accuracy of few hundreds of arcsecond on diameter's measurements. The French space mission PICARD with a few milliarcseconds accuray. With PICARD-SOL instruments located at the plateau of Calern the role of the atmosphere in ground-based measurements will be clarified. CLAVIUS is a Swiss-Italian project based on drift-scan method, free from optical distortions, where hourly circles transits will be monitored with fast CMOS sensors in different wavebands. The will run at IRSOL Gregory-Coudé telescope.

  15. On finding minimum-diameter clique trees

    SciTech Connect

    Blair, J.R.S. . Dept. of Computer Science); Peyton, B.W. )

    1991-08-01

    It is well-known that any chordal graph can be represented as a clique tree (acyclic hypergraph, join tree). Since some chordal graphs have many distinct clique tree representations, it is interesting to consider which one is most desirable under various circumstances. A clique tree of minimum diameter (or height) is sometimes a natural candidate when choosing clique trees to be processed in a parallel computing environment. This paper introduces a linear time algorithm for computing a minimum-diameter clique tree. The new algorithm is an analogue of the natural greedy algorithm for rooting an ordinary tree in order to minimize its height. It has potential application in the development of parallel algorithms for both knowledge-based systems and the solution of sparse linear systems of equations. 31 refs., 7 figs.

  16. Quantification of pulmonary vessel diameter in low-dose CT images

    NASA Astrophysics Data System (ADS)

    Rudyanto, Rina D.; Ortiz de Solórzano, Carlos; Muñoz-Barrutia, Arrate

    2015-03-01

    Accurate quantification of vessel diameter in low-dose Computer Tomography (CT) images is important to study pulmonary diseases, in particular for the diagnosis of vascular diseases and the characterization of morphological vascular remodeling in Chronic Obstructive Pulmonary Disease (COPD). In this study, we objectively compare several vessel diameter estimation methods using a physical phantom. Five solid tubes of differing diameters (from 0.898 to 3.980 mm) were embedded in foam, simulating vessels in the lungs. To measure the diameters, we first extracted the vessels using either of two approaches: vessel enhancement using multi-scale Hessian matrix computation, or explicitly segmenting them using intensity threshold. We implemented six methods to quantify the diameter: three estimating diameter as a function of scale used to calculate the Hessian matrix; two calculating equivalent diameter from the crosssection area obtained by thresholding the intensity and vesselness response, respectively; and finally, estimating the diameter of the object using the Full Width Half Maximum (FWHM). We find that the accuracy of frequently used methods estimating vessel diameter from the multi-scale vesselness filter depends on the range and the number of scales used. Moreover, these methods still yield a significant error margin on the challenging estimation of the smallest diameter (on the order or below the size of the CT point spread function). Obviously, the performance of the thresholding-based methods depends on the value of the threshold. Finally, we observe that a simple adaptive thresholding approach can achieve a robust and accurate estimation of the smallest vessels diameter.

  17. Lasing in microdisks of ultrasmall diameter

    SciTech Connect

    Zhukov, A. E. Kryzhanovskaya, N. V.; Maximov, M. V.; Lipovskii, A. A.; Savelyev, A. V.; Bogdanov, A. A.; Shostak, I. I.; Moiseev, E. I.; Karpov, D. V.; Laukkanen, J.; Tommila, J.

    2014-12-15

    It is demonstrated by calculations and experimental results that room-temperature lasing can be obtained at the ground-state optical transition of InAs/InGaAs/GaAs quantum dots in optical microcavities with a record-small diameter of 1.5 μm. In 1-μm cavities, lasing occurs at the wavelength of one of the whispering-gallery modes within the band corresponding to the first excited-state optical transition.

  18. Effects of food diameter on bite size per mouthful and chewing behavior.

    PubMed

    Shiozawa, Kouichi; Ohnuki, Yoshiki; Mototani, Yasumasa; Umeki, Daisuke; Ito, Aiko; Saeki, Yasutake; Hanada, Nobuhiro; Okumura, Satoshi

    2016-01-01

    Obesity is well known to be associated with a wide variety of illnesses, and is an increasing problem not only in developed countries but also in developing countries. It is well known that large bite size contributes to excess energy intake and obesity, whereas an increased number of chews before swallowing the food bolus is associated with suppression of obesity. However, the effect of food diameter on bite size per mouthful and on chewing behavior remains poorly understood. Here, we examined the effects of food diameter on bite size and chewing behavior using a masticatory counter during the mastication of stick-type biscuits having the same length (10 cm) and ingredients, but with four different diameters (3.0, 3.5, 4.0, and 8.0 mm). Bite length and bite weight per mouthful were similar among the 3.0, 3.5, and 4.0 mm groups. However, bite length in the 8.0 mm group was significantly smaller, whereas bite weight was significantly greater than in the 3.0/3.5 mm groups. Further, the number of chews gradually increased, whereas the number of chews per bite weight gradually decreased, with an increase of biscuit diameter. These results indicate that a smaller biscuit diameter is associated with a smaller bite weight per mouthful and a greater number of chews per bite weight. This is the first report to quantity the effect of food diameter on bite weight per mouthful and on chewing behavior; these results should be helpful in the design of effective, safe, and low-cost behavioral modification therapy to combat obesity. PMID:26493202

  19. Diameter-dependent hydrophobicity in carbon nanotubes

    NASA Astrophysics Data System (ADS)

    Kyakuno, Haruka; Fukasawa, Mamoru; Ichimura, Ryota; Matsuda, Kazuyuki; Nakai, Yusuke; Miyata, Yasumitsu; Saito, Takeshi; Maniwa, Yutaka

    2016-08-01

    Single-wall carbon nanotubes (SWCNTs) are a good model system that provides atomically smooth nanocavities. It has been reported that water-SWCNTs exhibit hydrophobicity depending on the temperature T and the SWCNT diameter D. SWCNTs adsorb water molecules spontaneously in their cylindrical pores around room temperature, whereas they exhibit a hydrophilic-hydrophobic transition or wet-dry transition (WDT) at a critical temperature Twd ≈ 220-230 K and above a critical diameter Dc ≈ 1.4-1.6 nm. However, details of the WDT phenomenon and its mechanism remain unknown. Here, we report a systematic experimental study involving X-ray diffraction, optical microscopy, and differential scanning calorimetry. It is found that water molecules inside thick SWCNTs (D > Dc) evaporate and condense into ice Ih outside the SWCNTs at Twd upon cooling, and the ice Ih evaporates and condenses inside the SWCNTs upon heating. On the other hand, residual water trapped inside the SWCNTs below Twd freezes. Molecular dynamics simulations indicate that upon lowering T, the hydrophobicity of thick SWCNTs increases without any structural transition, while the water inside thin SWCNTs (D < Dc) exhibits a structural transition, forming an ordered ice. This ice has a well-developed hydrogen bonding network adapting to the cylindrical pores of the SWCNTs. Thus, the unusual diameter dependence of the WDT is attributed to the adaptability of the structure of water to the pore dimension and shape.

  20. Effect of fiber diameter and matrix alloys on impact-resistant boron/aluminum composites

    NASA Technical Reports Server (NTRS)

    Mcdanels, D. L.; Signorelli, R. A.

    1976-01-01

    Efforts to improve the impact resistance of B/Al are reviewed and analyzed. Nonstandard thin-sheet charpy and Izod impact tests and standard full-size Charpy impact tests were conducted on composites containing unidirectional 0.10mm, 0.14mm, and 0.20mm diameter boron fibers in 1100, 2024, 5052, and 6061 Al matrices. Impact failure modes of B/Al are proposed in an attempt to describe the mechanisms involved and to provide insight for maximizing impact resistance. The impact strength of B/Al was significantly increased by proper selection of materials and processing. The use of a ductile matrix and large diameter boron fibers gave the highest impact strengths. This combination resulted in improved energy absorption through matrix shear deformation and multiple fiber breakage.

  1. Side Elevation, End Elevation, Cross Section, 1/2 Roof Plan, 1/2 ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Side Elevation, End Elevation, Cross Section, 1/2 Roof Plan, 1/2 Reflected Plan, 1/2 Floor Plan, 1/2 Reflected Plan - Jack's Mill Covered Bridge, Spanning Henderson Creek, Oquawka, Henderson County, IL

  2. Internal Diameter HVAF Spraying for Wear and Corrosion Applications

    NASA Astrophysics Data System (ADS)

    Lyphout, C.; Björklund, S.

    2015-01-01

    Electrolytic hard chrome (EHC) methods are still widely utilized in the printing, automotive and off-shore industries. Alternative methods to EHC have been widely developed in the past decade by conventional HVOF processes and more recently HVAF systems, which are processing at higher kinetic energy and more particularly at lower temperature, significantly increasing wear and corrosion resistance properties. A dedicated internal diameter HVAF system is here presented, and coatings characteristics are compared to the one obtained by standard HVAF coatings. Specially R&D designed fixtures with inside bore of 200 mm have been manufactured for this purpose, with a possibility to spray samples at increasing depth up to 400 mm while simulating closed bottom bore spraying. WC-based and Cr3C2-based powder feedstock materials have been deposited onto high-strength steel substrates. Respective coating microstructures, thermally induced stresses and corrosion resistance are discussed for further optimization of coating performances. The fact that the ID-HVAF system is utilized both for spraying and gritblasting procedures is also given a particular interest.

  3. Low-Friction Minilaparoscopy Outperforms Regular 5-mm and 3-mm Instruments for Precise Tasks

    PubMed Central

    Firme, Wood A.; Lima, Diego L.; de Paula Lopes, Vladmir Goldstein; Montandon, Isabelle D.; Filho, Flavio Santos; Shadduck, Phillip P.

    2015-01-01

    Background and Objectives: Therapeutic laparoscopy was incorporated into surgical practice more than 25 y ago. Several modifications have since been developed to further minimize surgical trauma and improve results. Minilaparoscopy, performed with 2- to 3-mm instruments was introduced in the mid 1990s but failed to attain mainstream use, mostly because of the limitations of the early devices. Buoyed by a renewed interest, new generations of mini instruments are being developed with improved functionality and durability. This study is an objective evaluation of a new set of mini instruments with a novel low-friction design. Method: Twenty-two medical students and 22 surgical residents served as study participants. Three designs of laparoscopic instruments were evaluated: conventional 5 mm, traditional 3 mm, and low-friction 3 mm. The instruments were evaluated with a standard surgical simulator, emulating 4 exercises of various complexities, testing grasping, precise 2-handed movements, and suturing. The metric measured was time to task completion, with 5 replicates for every combination of instrument–exercise–participant. Results: For all 4 tasks, the instrument design that performed the best was the same in both the medical student and surgical resident groups. For the gross-grasping task, the 5-mm conventional instruments performed best, followed by the low-friction mini instruments. For the 3 more complex and precise tasks, the low-friction mini instruments outperformed both of the other instrument designs. Conclusion: In standard surgical simulator exercises, low-friction minilaparoscopic instruments outperformed both conventional 3- and 5-mm laparoscopic instruments for precise tasks. PMID:26390530

  4. Forced Convection Heat Transfer of Liquid Hydrogen Through a 200-mm Long Heated Tube

    NASA Astrophysics Data System (ADS)

    Tatsumoto, Hideki; Shirai, Yasuyuki; Shiotsu, Masahiro; Hata, Koichi; Naruo, Yoshihiro; Kobayashi, Hiroaki; Inatani, Yoshifumi; Kinoshita, Katsuhiro

    The heat transfer from the inner side of a vertically- mounted heated tube with a length of 200.0 mm and a diameter of 6.0 mm to a forced flow of liquid hydrogen was measured for wide ranges of flow rate and liquid temperature. The non-boiling heat transfer coefficients agreed well with the Dittus -Boelter equation. The heat fluxes at departure from nucleate boiling (DNB) were higher for higher flow velocities and greater subcooling. The effect of the tube length on the DNB heat flux was clarified through comparison with our previous data. It was confirmed that the experimental data agreed well with the authors' DNB correlation.

  5. A comparison of 9-inch, 70mm, and 35mm cameras

    NASA Technical Reports Server (NTRS)

    Clegg, R. H.; Scherz, J. P.

    1975-01-01

    Successful aerial photography depends on aerial cameras that provide acceptable photographs within the cost restrictions of the job. For topographic mapping where ultimate accuracy is required, only large-format mapping cameras will suffice. For mapping environmental patterns of vegetation, soils, or water pollution, 9-inch cameras often exceed accuracy and cost requirements, and small formats may be an overall better choice. In choosing the best camera for environmental mapping, relative capabilities and costs must be understood. This study compares resolution, photo interpretation potential, metric accuracy, and cost of 9-inch, 70 mm, and 35 mm cameras for obtaining simultaneous color and color-infrared photography for environmental mapping purposes.

  6. Larger Maximum Tumor Diameter at Radical Prostatectomy Is Associated With Increased Biochemical Failure, Metastasis, and Death From Prostate Cancer After Salvage Radiation for Prostate Cancer

    SciTech Connect

    Johnson, Skyler B.; Hamstra, Daniel A.; Jackson, William C.; Zhou, Jessica; Foster, Benjamin; Foster, Corey; Song, Yeohan; Li, Darren; Palapattu, Ganesh S.; Kunju, Lakshmi; Mehra, Rohit; Sandler, Howard; Feng, Felix Y.

    2013-10-01

    Purpose: To investigate the maximum tumor diameter (MTD) of the dominant prostate cancer nodule in the radical prostatectomy specimen as a prognostic factor for outcome in patients treated with salvage external beam radiation therapy (SRT) for a rising prostate-specific antigen (PSA) value after radical prostatectomy. Methods and Materials: From an institutional cohort of 575 patients treated with SRT, data on MTD were retrospectively collected. The impact of MTD on biochemical failure (BF), metastasis, and prostate cancer-specific mortality (PCSM) was assessed on univariate and multivariate analysis using Kaplan-Meier and Cox proportional hazards models. Results: In the 173 patients with MTD data available, median follow-up was 77 months (interquartile range, 47-104 months) after SRT, and median MTD was 18 mm (interquartile range, 13-22 mm). Increasing MTD correlated with increasing pT stage, Gleason score, presence of seminal vesicle invasion, and lymph node invasion. Receiver operating characteristic curve analysis identified MTD of >14 mm to be the optimal cut-point. On univariate analysis, MTD >14 mm was associated with an increased risk of BF (P=.02, hazard ratio [HR] 1.8, 95% confidence interval [CI] 1.2-2.8), metastasis (P=.002, HR 4.0, 95% CI 2.1-7.5), and PCSM (P=.02, HR 8.0, 95% CI 2.9-21.8). On multivariate analysis MTD >14 mm remained associated with increased BF (P=.02, HR 1.9, 95% CI 1.1-3.2), metastasis (P=.02, HR 3.4, 95% CI 1.2-9.2), and PCSM (P=.05, HR 9.7, 95% CI 1.0-92.4), independent of extracapsular extension, seminal vesicle invasion, positive surgical margins, pre-RT PSA value, Gleason score, and pre-RT PSA doubling time. Conclusions: For patients treated with SRT for a rising PSA value after prostatectomy, MTD at time of radical prostatectomy is independently associated with BF, metastasis, and PCSM. Maximum tumor diameter should be incorporated into clinical decision making and future clinical risk assessment tools for those patients

  7. Resonant Frequency Dependence on Outer Diameter of High Tc rf-SQUID

    NASA Astrophysics Data System (ADS)

    Ashizuka, Takuya; Sakai, Akira; Miyato, Yuji; Itozaki, Hideo

    Superconducting quantum interference devices (SQUIDs) have been applied to various magnetic sensing. An rf-SQUID can measure magnetic signals by applying external rf-magnetic field whose frequency is tuned to its resonance. Our rf-SQUID having the outer diameter of 3.5 mm needed a substrate resonator to operate it within the operation frequency range of our using FLL electronics. The designs of the rf-SQUID and the resonator were critical to the resonant frequency and the effective area. In this paper, the outer diameter dependence of the resonant frequency and the effective area were investigated by both the electromagnetic simulations and the experiments. The results showed that the rf-SQUID having the larger outer diameter has the smaller resonant frequency and the larger effective area. The rf-SQUIDs having the larger outer diameter were fabricated according to the simulation results. They could be operated within the operation frequency range even though a resonator was omitted.

  8. Biomechanics and load resistance of small-diameter and mini dental implants: a review of literature.

    PubMed

    Hasan, Istabrak; Bourauel, Christoph; Mundt, Torsten; Stark, Helmut; Heinemann, Friedhelm

    2014-02-01

    In recent years, the application of small-diameter and mini dental implants to support removable and fixed prosthesis has dramatically increased. However, the success of these implants under functional biting forces and the reaction of the bone around them need to be analyzed. This review was aimed to present studies that deal with the fatigue life of small-diameter and mini dental implants under normal biting force, and their survival rate. The numerical and experimental studies concluded that an increase in the risk of bone damage or implant failure may be assumed in critical clinical situations and implants with <3 mm diameter have a risk of fracture in clinical practice. The survival rate of the small-diameter and mini dental implants over 5 years was 98.3-99.4%. PMID:24293447

  9. Hypervelocity impact on brittle materials of semi-infinite thickness: fracture morphology related to projectile diameter

    NASA Astrophysics Data System (ADS)

    Taylor, Emma A.; Kay, Laurie; Shrine, Nick R. G.

    Hypervelocity impact on brittle materials produces features not observed on ductile targets. Low fracture toughness and high yield strength produce a range of fracture morphologies including cracking, spallation and shatter. For sub-mm diameter projectiles, impact features are characterised by petaloid spallation separated by radial cracks. The conchoidal or spallation diameter is a parameter in current cratering equations. An alternative method for interpreting hypervelocity impacts on glass targets of semi-infinite thickness is tested against impact data produced using the Light Gas Gun (LGG) facility at the University of Kent at Canterbury (UKC), U.K. Spherical projectiles of glass and other materials with diameters 30-300 μm were fired at ~5 km s^-1 at a glass target of semi-infinite thickness. The data is used to test a power law relationship between projectile diameter and crack length. The results of this work are compared with published cratering/spallation equations for brittle materials.

  10. Large-diameter femoral heads in total hip arthroplasty: an evidence-based review.

    PubMed

    Banerjee, Samik; Pivec, Robert; Issa, Kimona; Kapadia, Bhaveen H; Khanuja, Harpal S; Mont, Michael A

    2014-11-01

    Recent advances in the wear characteristics and material properties of highly cross-linked polyethyl-ene and fourth-generation ceramic bearings have led to increasing use of large-diameter (≥ 36 mm) femoral heads in total hip arthroplasty (THA). In this article, we review the current concepts and principles behind use of large-diameter ceramic or cobalt-chromium femoral heads on polyethylene bearings in THA. We specifically review the biomechanics, some of the early concerns about polyethylene wear and rim fractures, recent improvements in material properties of polyethylene and ceramic bearings, dislocation rates, and clinical and functional outcomes of large-diameter heads in THA. Recent literature suggests that the incidence of dislocation has been substantially reduced because of improvements in jump distance and impingement-free range of motion with use of large-diameter heads. Limited evidence suggests excellent short-term and midterm clinical and functional outcomes with these heads. PMID:25379747

  11. Calibration of area based diameter distribution with individual tree based diameter estimates using airborne laser scanning

    NASA Astrophysics Data System (ADS)

    Xu, Qing; Hou, Zhengyang; Maltamo, Matti; Tokola, Timo

    2014-07-01

    Diameter distribution is essential for calculating stem volume and timber assortments of forest stands. A new method was proposed in this study to improve the estimation of stem volume and timber assortments, by means of combining the Area-based approach (ABA) and individual tree detection (ITD), the two main approaches to deriving forest attributes from airborne laser scanning (ALS) data. Two methods, replacement, and histogram matching were employed to calibrate ABA-derived diameter distributions with ITD-derived diameter estimates at plot level. The results showed that more accurate estimates were obtained when calibrations were applied. In view of the highest accuracy between ABA and ITD, calibrated diameter distributions decreased its relative RMSE of the estimated entire growing stock, saw log and pulpwood fractions by 2.81%, 3.05% and 7.73% points at best, respectively. Calibration improved pulpwood fraction significantly, which contributed to the negligible bias of the estimated entire growing stock.

  12. Variable diameter wind turbine rotor blades

    DOEpatents

    Jamieson, Peter McKeich; Hornzee-Jones, Chris; Moroz, Emilian M.; Blakemore, Ralph W.

    2005-12-06

    A system and method for changing wind turbine rotor diameters to meet changing wind speeds and control system loads is disclosed. The rotor blades on the wind turbine are able to adjust length by extensions nested within or containing the base blade. The blades can have more than one extension in a variety of configurations. A cable winching system, a hydraulic system, a pneumatic system, inflatable or elastic extensions, and a spring-loaded jack knife deployment are some of the methods of adjustment. The extension is also protected from lightning by a grounding system.

  13. Stellar Angular Diameter Relations for Microlensing Surveys

    NASA Astrophysics Data System (ADS)

    Adams, Arthur; Boyajian, Tabetha S.; von Braun, Kaspar

    2016-01-01

    Determining the physical properties of microlensing events depends on having accurate angular radii of the source star. Using long-baseline optical interferometry we are able to determine the angular sizes of nearby stars with uncertainties less than 2 percent. We present empirical estimates of angular diameters for both dwarfs/subgiants and giant stars as functions of five color indices which are relevant to planned microlensing surveys. We find in all considered colors that metallicity does not play a statistically significant role in predicting stellar size for the samples of stars considered.

  14. A 30-cm diameter argon ion source

    NASA Technical Reports Server (NTRS)

    Sovey, J. S.

    1976-01-01

    A 30 cm diameter argon ion source was evaluated. Ion source beam currents up to 4a were extracted with ion energies ranging from 0.2 to 1.5 KeV. An ion optics scaling relation was developed for predicting ion beam extraction capability as a function of total extraction voltage, gas type, and screen grid open area. Ignition and emission characteristics of several hollow cathode geometries were assessed for purposes of defining discharge chamber and neutralizer cathodes. Also presented are ion beam profile characteristics which exhibit broad beam capability well suited for ion beam sputtering applications.

  15. A Variable Diameter Short Haul Civil Tiltrotor

    NASA Technical Reports Server (NTRS)

    Wang, James M.; Jones, Christopher T.; Nixon, Mark W.

    1999-01-01

    The Short-Haul-Civil-tiltrotor (SHCT) component of the NASA Aviation System Capacity Program is an effort to develop the technologies needed for a potential 40-passenger civil tiltrotor. The variable diameter tiltrotor (VDTR) is a Sikorsky concept aimed at improving tiltrotor hover and cruise performance currently limited by disk loading that is much higher in hover than conventional helicopter, and much lower in cruise than turbo-prop systems. This paper describes the technical merits of using a VDTR on a SHCT aircraft. The focus will be the rotor design.

  16. Thread gauge for measuring thread pitch diameters

    DOEpatents

    Brewster, Albert L.

    1985-01-01

    A thread gauge which attaches to a vernier caliper to measure the thread pitch diameter of both externally threaded and internally threaded parts. A pair of anvils are externally threaded with threads having the same pitch as those of the threaded part. Each anvil is mounted on a stem having a ball on which the anvil can rotate to properly mate with the parts to which the anvils are applied. The stems are detachably secured to the caliper blades by attachment collars having keyhole openings for receiving the stems and caliper blades. A set screw is used to secure each collar on its caliper blade.

  17. Thread gauge for measuring thread pitch diameters

    DOEpatents

    Brewster, A.L.

    1985-11-19

    A thread gauge which attaches to a vernier caliper to measure the thread pitch diameter of both externally threaded and internally threaded parts is disclosed. A pair of anvils are externally threaded with threads having the same pitch as those of the threaded part. Each anvil is mounted on a stem having a ball on which the anvil can rotate to properly mate with the parts to which the anvils are applied. The stems are detachably secured to the caliper blades by attachment collars having keyhole openings for receiving the stems and caliper blades. A set screw is used to secure each collar on its caliper blade. 2 figs.

  18. The diameter and albedo of 1943 Anteros

    NASA Technical Reports Server (NTRS)

    Veeder, G. J.; Tedesco, E. F.; Tholen, D. J.; Tokunaga, A.; Matthews, K.; Neugebauer, G.; Soifer, B. T.; Kowal, C.

    1981-01-01

    The results of broadband visual and infrared photometry of the Apollo-Amor asteroid 1943 Anteros during its 1980 apparition are reported. By means of a radiometric model, a diameter of 2.3 + or - 0.2 km and a visual geometric albedo of 0.13 + or - 0.03 is calculated. The albedo and reflectance spectrum of Anteros imply that it is a type S asteroid. Thus, Anteros may have a silicate surface similar to other Apollo-Amor asteroids as well as some stony-iron meteorites.

  19. Diagnostics for a 1.2 kA, 1 MeV, electron induction injector

    NASA Astrophysics Data System (ADS)

    Houck, T. L.; Anderson, D. E.; Eylon, S.; Henestroza, E.; Lidia, S. M.; Vanecek, D. L.; Westenskow, G. A.; Yu, S. S.

    1998-12-01

    We are constructing a 1.2 kA, 1 MeV, electron induction injector as part of the RTA program, a collaborative effort between LLNL and LBNL to develop relativistic klystrons for Two-Beam Accelerator applications. The RTA injector will also be used in the development of a high-gradient, low-emittance, electron source and beam diagnostics for the second axis of the Dual Axis Radiographic Hydrodynamic Test (DARHT) Facility. The electron source will be a 3.5″-diameter, thermionic, flat-surface, m-type cathode with a maximum shroud field stress of approximately 165 kV/cm. Additional design parameters for the injector include a pulse length of over 150 ns flat top (1% energy variation), and a normalized edge emittance of less than 200 π-mm-mr. Precise measurement of the beam parameters is required so that performance of the RTA injector can be confidently scaled to the 4 kA, 3 MeV, and 2-microsecond pulse parameters of the DARHT injector. Planned diagnostics include an isolated cathode with resistive divider for direct measurement of current emission, resistive wall and magnetic probe current monitors for measuring beam current and centroid position, capacitive probes for measuring A-K gap voltage, an energy spectrometer, and a pepperpot emittance diagnostic. Details of the injector, beam line, and diagnostics are presented.

  20. Measurement of Diameter Changes during Irradiation Testing

    SciTech Connect

    Davis, K. L.; Knudson, D. L.; Crepeau, J. C.; Solstad, S.

    2015-03-01

    New materials are being considered for fuel, cladding, and structures in advanced and existing nuclear reactors. Such materials can experience significant dimensional and physical changes during irradiation. Currently in the US, such changes are measured by repeatedly irradiating a specimen for a specified period of time and then removing it from the reactor for evaluation. The time and labor to remove, examine, and return irradiated samples for each measurement makes this approach very expensive. In addition, such techniques provide limited data and handling may disturb the phenomena of interest. In-pile detection of changes in geometry is sorely needed to understand real-time behavior during irradiation testing of fuels and materials in high flux US Material and Test Reactors (MTRs). This paper presents development results of an advanced Linear Variable Differential Transformer-based test rig capable of detecting real-time changes in diameter of fuel rods or material samples during irradiation in US MTRs. This test rig is being developed at the Idaho National Laboratory and will provide experimenters with a unique capability to measure diameter changes associated with fuel and cladding swelling, pellet-clad interaction, and crud buildup.

  1. Physical parameters of very small diameter 10 MV X-ray beams for linac-based stereotactic radiosurgery

    NASA Astrophysics Data System (ADS)

    Sham, Edwin

    Physical aspects of very small diameter X-ray beams used for a linac-based stereotactic radiosurgery are presented in this thesis. A 10 MV linac was used as the radiation source. Very small 10 MV photon fields with diameters of 1.5 mm, 3 mm, and 5 mm are produced by special collimators attached to the treatment head of the linac. The radiation beam data were measured with a small field diode detector as well as radiographic and radiochromic films. Measured beam parameters were compared with the same parameters calculated with Monte Carlo (MC) simulations. For very small photon fields with diameters on the order of the focal spot size, MC calculations show that both the percentage depth dose (PDD) distributions and dose profiles are sensitive to the focal spot size. A simple sliding slit technique was developed to measure the focal spot size and shape for accurate MC simulations of very small diameter beams. The measured focal spot of the 10 MV linac is elliptical in shape and fitted by a Gaussian distribution with full-widths-at-half-maximum (FWHMs) of 2.05 mm and 1.34 mm in the principal axes of the ellipse. A Gaussian circle equivalent in area to the experimentally determined focal spot ellipse was used in MC simulations. The resulting PDD and beam profile calculations are in good agreement with the measurements. Dynamic radiosurgery with very small diameter photon beams was carried out using the 10 MV linac. Radiosurgical isodose distributions were measured with radiographic films in a spherical head phantom and calculated with the MC technique. A good agreement between the measured and MC-calculated isodose distributions for very small diameter fields is achieved. The displacement of the center of the measured isodose distributions relative to the laser-defined isocenter was on the order of 0.7 mm. All these results show the potential of linac-based radiosurgery with very small diameter photon beams for clinical use.

  2. Sampling efficiency of modified 37-mm sampling cassettes using computational fluid dynamics.

    PubMed

    Anthony, T Renée; Sleeth, Darrah; Volckens, John

    2016-01-01

    In the U.S., most industrial hygiene practitioners continue to rely on the closed-face cassette (CFC) to assess worker exposures to hazardous dusts, primarily because ease of use, cost, and familiarity. However, mass concentrations measured with this classic sampler underestimate exposures to larger particles throughout the inhalable particulate mass (IPM) size range (up to aerodynamic diameters of 100 μm). To investigate whether the current 37-mm inlet cap can be redesigned to better meet the IPM sampling criterion, computational fluid dynamics (CFD) models were developed, and particle sampling efficiencies associated with various modifications to the CFC inlet cap were determined. Simulations of fluid flow (standard k-epsilon turbulent model) and particle transport (laminar trajectories, 1-116 μm) were conducted using sampling flow rates of 10 L min(-1) in slow moving air (0.2 m s(-1)) in the facing-the-wind orientation. Combinations of seven inlet shapes and three inlet diameters were evaluated as candidates to replace the current 37-mm inlet cap. For a given inlet geometry, differences in sampler efficiency between inlet diameters averaged less than 1% for particles through 100 μm, but the largest opening was found to increase the efficiency for the 116 μm particles by 14% for the flat inlet cap. A substantial reduction in sampler efficiency was identified for sampler inlets with side walls extending beyond the dimension of the external lip of the current 37-mm CFC. The inlet cap based on the 37-mm CFC dimensions with an expanded 15-mm entry provided the best agreement with facing-the-wind human aspiration efficiency. The sampler efficiency was increased with a flat entry or with a thin central lip adjacent to the new enlarged entry. This work provides a substantial body of sampling efficiency estimates as a function of particle size and inlet geometry for personal aerosol samplers. PMID:26513395

  3. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 43 Public Lands: Interior 2 2014-10-01 2014-10-01 false Contents. 2812.1-2 Section 2812.1-2 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT... Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of...

  4. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Contents. 2812.1-2 Section 2812.1-2 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT... Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of...

  5. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Contents. 2812.1-2 Section 2812.1-2 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT... Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of...

  6. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 43 Public Lands: Interior 2 2012-10-01 2012-10-01 false Contents. 2812.1-2 Section 2812.1-2 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT... Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of...

  7. 16 CFR 1.2 - Procedure.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Procedure. 1.2 Section 1.2 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.2 Procedure. (a) Application. The request for advice...

  8. 7 CFR 1.2 - Policy.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 1 2011-01-01 2011-01-01 false Policy. 1.2 Section 1.2 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.2 Policy. (a) Agencies of USDA shall comply with the time limits set forth in the FOIA and in this subpart for responding to...

  9. 7 CFR 1.2 - Policy.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 1 2014-01-01 2014-01-01 false Policy. 1.2 Section 1.2 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.2 Policy. (a) Agencies of USDA shall comply with the time limits set forth in the FOIA and in this subpart for responding to...

  10. 7 CFR 1.2 - Policy.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 1 2012-01-01 2012-01-01 false Policy. 1.2 Section 1.2 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.2 Policy. (a) Agencies of USDA shall comply with the time limits set forth in the FOIA and in this subpart for responding to...

  11. 11 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 11 Federal Elections 1 2010-01-01 2010-01-01 false Definitions. 1.2 Section 1.2 Federal Elections FEDERAL ELECTION COMMISSION PRIVACY ACT § 1.2 Definitions. As defined in the Privacy Act of 1974 and for the purposes of this part, unless otherwise required by the context, the following terms shall have these meanings: Act means the...

  12. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2011 CFR

    2008-10-01

    ... 43 Public Lands: Interior 2 2008-10-01 2008-10-01 false Contents. 2812.1-2 Section 2812.1-2 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT.... and Coos Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of...

  13. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2011 CFR

    1996-10-01

    ... 43 Public Lands: Interior 2 1996-10-01 1996-10-01 false Contents. 2812.1-2 Section 2812.1-2 LAND RESOURCE MANAGEMENT (2000) TRAMROADS AND LOGGING ROADS Over O. and C. and Coos Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of any unincorporated association which...

  14. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2010 CFR

    2000-10-01

    ... 43 Public Lands: Interior 2 2000-10-01 2000-10-01 false Contents. 2812.1-2 Section 2812.1-2 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT,DEPARTMENT OF... Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of any...

  15. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2011 CFR

    2002-10-01

    ... 43 Public Lands: Interior 2 2002-10-01 2002-10-01 false Contents. 2812.1-2 Section 2812.1-2 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT... Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of...

  16. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2013 CFR

    2006-10-01

    ... 43 Public Lands: Interior 2 2006-10-01 2006-10-01 false Contents. 2812.1-2 Section 2812.1-2 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT... Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of...

  17. 43 CFR 2812.1-2 - Contents.

    Code of Federal Regulations, 2012 CFR

    1997-10-01

    ... 43 Public Lands: Interior 2 1997-10-01 1997-10-01 false Contents. 2812.1-2 Section 2812.1-2 LAND RESOURCE MANAGEMENT (2000) TRAMROADS AND LOGGING ROADS Over O. and C. and Coos Bay Revested Lands § 2812.1-2 Contents. (a) An individual applicant and each member of any unincorporated association which...

  18. 7 CFR 1.2 - Policy.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 1 2010-01-01 2010-01-01 false Policy. 1.2 Section 1.2 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.2 Policy. (a) Agencies of USDA shall comply with the time limits set forth in the FOIA and in this subpart for responding to...

  19. 7 CFR 1.2 - Policy.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 1 2013-01-01 2013-01-01 false Policy. 1.2 Section 1.2 Agriculture Office of the Secretary of Agriculture ADMINISTRATIVE REGULATIONS Official Records § 1.2 Policy. (a) Agencies of USDA shall comply with the time limits set forth in the FOIA and in this subpart for responding to...

  20. 16 CFR 1.2 - Procedure.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Procedure. 1.2 Section 1.2 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.2 Procedure. (a) Application. The request for advice...

  1. 45 CFR 1210.1-2 - Scope.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Scope. 1210.1-2 Section 1210.1-2 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE VISTA TRAINEE DESELECTION AND VOLUNTEER EARLY TERMINATION PROCEDURES General § 1210.1-2 Scope. (a) This part applies to all Trainees and...

  2. 45 CFR 1211.1-2 - Applicability.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Applicability. 1211.1-2 Section 1211.1-2 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE VOLUNTEER GRIEVANCE PROCEDURES § 1211.1-2 Applicability. This part applies to all volunteers enrolled under part A of title I of the...

  3. 16 CFR 1.2 - Procedure.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Procedure. 1.2 Section 1.2 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.2 Procedure. (a) Application. The request for advice...

  4. 16 CFR 1.2 - Procedure.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Procedure. 1.2 Section 1.2 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.2 Procedure. (a) Application. The request for advice...

  5. 16 CFR 1.2 - Procedure.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Procedure. 1.2 Section 1.2 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.2 Procedure. (a) Application. The request for advice...

  6. Diameter and position effect determination of diaphragm on hybrid rocket motor

    NASA Astrophysics Data System (ADS)

    Sun, Xingliang; Tian, Hui; Cai, Guobiao

    2016-09-01

    This study is aimed to determine and better reveal the mixture enhancement and regression rate distribution of hybrid rocket motor with diaphragm by numerical approach. A numerical model based on the computational fluid dynamics software is built to simulate the flow and combustion inside the motor. Four firing tests of the motor, including one without diaphragm and three with diaphragm, are conducted on a standard experimental system and also used as a reference for numerical simulation, the consistency between the simulation and experiment demonstrates that the numerical approach is an effective method to study the diaphragm effect on the motor performance. The flow field characteristic and regression rate distribution inside the hybrid rocket motor are then calculated to analyze the effect of position and diameter of the diaphragm. The results indicate that the diaphragm almost have no effect on the regression rate before it. However, the regression rate after the diaphragm has a strong dependence on the position and diameter of the diaphragm. As the diameter decreases and the position moves backward, the regression rate increases larger and larger, this is mainly due to the augmentation of the eddy generated by the diaphragm, which enhances the heat feedback transferred to the grain surface. When the diameter of diaphragm located at middle of grain decreases from 50 mm to 20 mm, regression rate is increased from 0.30 mm/s to 0.57 mm/s. The use of the diaphragm does cause a combustion efficiency improvement; the maximum combustion efficiency is enhanced to 98.9% from lower than 90% of the motor with no diaphragm. The increasing amplitude displays a square relation with the diameter decrease, since the entrainment of the eddy make the reactants mix sufficiently to release more energy inside the motor.

  7. MALT-45: The Galactic plane in 7mm

    NASA Astrophysics Data System (ADS)

    Jordan, Christopher; Walsh, Andrew; Voronkov, Maxim; Ellingsen, Simon

    2013-07-01

    MALT-45: The Galactic plane in 7mm MALT-45 is an untargeted Galactic plane survey searching for tracers of high mass star formation (HMSF) at 7mm. With the recent upgrades to the Australia Telescope Compact Array, we have been able to push the limits on observational efficiency to obtain a very sensitive blind survey in a short amount of time. Specifically, MALT-45 uses a fast on-the-fly mapping with 6 seconds per pointing, which results in a quarter-square-degree region being mapped in approximately 14 hours. Each region is Nyquist sampled and collects data in 12 spectral lines. The primary spectral lines of MALT-45 include: CS (1-0) - a high density gas tracer, which contrasts well with NH3 (1,1) from the similar HOPS survey; 44 GHz Class I methanol masers - the brightest of the Class I lines, it is poorly understood, and MALT-45 is one of the first surveys to thoroughly search for these masers; SiO (1-0) v=1,2,3 - typically associated with evolved stars, there have been rare associations with HMSF, and MALT-45 offers the potential to detect more. Other lines include thermal SiO (1-0) v=0, thermal methanol, C34S, OCS, and radio recombination lines H51a and H53a. Perhaps the most significant and innovative aspect of MALT-45 is the usage of ATCA autocorrelations. Each antenna of the ATCA is similar to Mopra, and by using all 6 antennae simultaneously, have a 6 fold increase in sensitivity per unit observation time. The autocorrelation data was only recently made available by the ATCA upgrade with the Compact Array Broadband Backend, and tools have been developed to allow this data processing. We present the first 5 square-degrees (l = 330 - 335, b = -0.5 - +0.5) of the Galactic plane mapped by MALT-45.

  8. PHOS Experiment: Thermal Response of a Large Diameter Pulsating Heat Pipe on Board REXUS-18 Rocket

    NASA Astrophysics Data System (ADS)

    Creatini, F.; Guidi, G. M.; Belfi, F.; Cicero, G.; Fioriti, D.; Di Prizio, D.; Piacquadio, S.; Becatti, G.; Orlandini, G.; Frigerio, A.; Fontanesi, S.; Nannipieri, P.; Rognini, M.; Morganti, N.; Filippeschi, S.; Di Marco, P.; Fanucci, L.; Baronti, F.; Mameli, M.; Marengo, M.; Manzoni, M.

    2015-09-01

    In the present work, the results of two Closed Loop Pulsating Heat Pipes (CLPHPs) tested on board REXUS-1 8 sounding rocket in order to get experimental data over a relatively broad reduced gravity period (about 90 s) are thoroughly discussed. The CLPHPs are partially filled with refrigerant FC-72 and have, respectively, an inner tube diameter larger (3 .0 mm) and slightly smaller (1 .6 mm) than a critical diameter defined on Earth gravity conditions. On ground, the small diameter CLPHP works as a real Pulsating Heat Pipe (PHP): the typical capillary slug flow pattern forms inside the device and the heat exchange is triggered by self-sustained thermally driven oscillations of the working fluid. Conversely, the large diameter CLPHP behaves like a two-phase thermosyphon in vertical position while does not operate in horizontal position as the working fluid stratifies within the tube and surface tension is not able to balance buoyancy. Then, the idea to test the CLPHPs under reduced gravity conditions: as soon as gravity reduces, buoyancy becomes less intense and the typical capillary slug flow pattern can also forms within a tube with a larger diameter. Moreover, this allows to increase the heat transfer rate and, consequently, to decrease the overall thermal resistance. Even though it was not possible to experience the expected reduced gravity conditions due to a failure of the yo-yo de-spin system, the thermal response to the peculiar acceleration field (hyper-gravity) experienced on board are thoroughly described.

  9. Effect of Orifice Diameter on Bubble Generation Process in Melt Gas Injection to Prepare Aluminum Foams

    NASA Astrophysics Data System (ADS)

    Yuan, Jianyu; Li, Yanxiang; Wang, Ningzhen; Cheng, Ying; Chen, Xiang

    2016-06-01

    The bubble generation process in conditioned A356 alloy melt through submerged spiry orifices with a wide diameter range (from 0.07 to 1.0 mm) is investigated in order to prepare aluminum foams with fine pores. The gas flow rate and chamber pressure relationship for each orifice is first determined when blowing gas in atmospheric environment. The effects of chamber pressure ( P c) and orifice diameter ( D o) on bubble size are then analyzed separately when blowing gas in melt. A three-dimensional fitting curve is obtained illustrating both the influences of orifice diameter and chamber pressure on bubble size based on the experimental data. It is found that the bubble size has a V-shaped relationship with orifice diameter and chamber pressure neighboring the optimized parameter ( D o = 0.25 mm, P c = 0.4 MPa). The bubble generation mechanism is proposed based on the Rayleigh-Plesset equation. It is found that the bubbles will not be generated until a threshold pressure difference is reached. The threshold pressure difference is dependent on the orifice diameter, which determines the time span of pre-formation stage and bubble growth stage.

  10. The relationship between superior vena cava diameter and collapsibility and central venous pressure.

    PubMed

    Cowie, B S; Kluger, R; Rex, S; Missant, C

    2015-05-01

    The aim of this study was to assess the relationship between superior vena cava (SVC) diameter, collapsibility and central venous pressure (CVP) in cardiac surgical patients. SVC maximum and minimum diameters, plus collapsibility with ventilation, were measured with transoesophageal echocardiography in the mid-oesophageal bicaval view with M-mode. Simultaneously, CVP was measured via the right atrial port of a pulmonary artery catheter. Measurements were possible in 91 out of 92 patients. The median CVP was 10 mmHg with a range of 2 to 19 mmHg. There was a weak, but statistically significant, correlation between CVP and SVC collapsibility index (r=-0.21, P=0.049). There was no statistically significant correlation between maximum SVC diameter and CVP. Maximum SVC diameter was statistically significantly correlated with weight (Pearson's r=0.28, P=0.008). There was no statistically significant correlation between CVP and age or body dimensions. Our findings indicate that SVC diameter and collapsibility are easily measured with transoesophageal echocardiography but do not reliably reflect CVP in anaesthetised cardiac surgical patients. PMID:25943610

  11. Large Diameter Limbs for Dilated Common Iliac Arteries in Endovascular Aneurysm Repair. Is It Safe?

    SciTech Connect

    Malagari, Katerina Brountzos, Elias; Gougoulakis, Alexandros; Papathanasiou, Matilda; Alexopoulou, Efthymia; Mastorakou, Renata; Kelekis, Dimitris

    2004-09-15

    In this prospective study we examined whether dilated common iliac arteries (CIAs) can provide a safe distal seal in endovascular aneurysm repair (EVAR) with the use of bifurcated stent grafts with large diameter limbs. Sixteen patients with 26 dilated CIAs with a diameter of {>=}6 mm who were offered EVAR using stent grafts with large diameter limbs were included in the study (Group A). Forty-two patients who also underwent EVAR without iliac dilatation, matched for age, sex and surgical risk were used for comparison (controls-Group B). In group A mean CIA diameter was 18.2 mm (16-28) and mean abdominal aortic aneurysm (AAA) diameter was 6.87 {+-} 1.05 cm; mean age was 77.2 {+-} 4.8 yrs (67-81). Mean follow-up was 33.6 months (2.8 yrs). CIA diameter changes and development of endoleaks were assessed by CT angiography (CTA). Overall iliac dilatation was present in 16/58 of our patients (27.6%). In 10 patients dilatation was bilateral (17.3%). Partial or complete flow to the internal iliac artery (IIA) territories was preserved in all patients post-EVAR. On follow-up, stable caliber of the dilated CIAs was observed in 21 patients (84%), enlargement of 1mm in 3 (16%), and failure of the distal attachment in 1 (6.2%). Compared to the control group there was no statistical significance in the incidence of complications. Dilated common iliac arteries provide a safe distal seal in patients who have undergone EVAR, thus obviating the need for additional endovascular procedures and sparing flow in the IIA vascular bed.

  12. The Effects of Bronchoscope Diameter on the Diagnostic Yield of Transbronchial Lung Biopsy of Peripheral Pulmonary Nodules

    PubMed Central

    Lee, Nakwon; Kim, Sang-Ha; Kwon, Woocheol; Lee, Myoung Kyu; Yong, Suk Joong; Shin, Kye Chul; Jung, Ye-Ryung; Choi, Yeun Seoung; Choi, Jiwon; Choi, Ji Sun

    2014-01-01

    Background Transbronchial lung biopsy (TBLB) is a valuable diagnostic tool for peripheral pulmonary lesions. The diagnostic yield of TBLB reportedly ranges from 41%-60%. Many studies demonstrated the various factors that influence the yield of TBLB, including size, location, and distance from the carina or pleura. However, no study has evaluated the effects of the bronchoscope diameter. We evaluated whether the bronchoscope diameter affected the diagnostic yield of TBLB. Methods We reviewed records from 178 patients who underwent TBLB using bronchoscopes of two different diameters (5.7 mm, thick outer diameter, Olympus BF-200; 4.9 mm, thin, BF-260). The fluoroscopic guidance rates, yield of TBLB and flexible bronchoscopy (FB) were compared between the two groups. Additionally, we compared the results of the procedures with respect to diagnosis, distance from the pleura, and size of the lesion. Results The results of fluoroscopic guidance, TBLB, and FB yield using thin diameter bronchoscope were significantly better than those obtained with a thick diameter bronchoscope (p=0.021, p=0.036, and p=0.010, respectively). Particularly, when the distance from the pleura was ≤ 10 mm, success rates for fluoroscopic guidance and FB with thin bronchoscope were higher (p=0.013 and p=0.033, respectively), as compared to with thick bronchoscope. Conclusion A thinner diameter bronchoscope increased the yield of bronchoscopy, and bronchial washing in conjunction with TBLB was useful in the diagnosis of peripheral pulmonary nodules. PMID:25580141

  13. Planetary brightness temperature measurements at 8.6 mm and 3.1 mm wavelengths.

    NASA Technical Reports Server (NTRS)

    Ulich, B. L.; Cogdell, J. R.; Davis, J. H.

    1973-01-01

    New measurements of the sun, moon, Mercury, Venus, Mars, Jupiter, and Saturn at 3.1- and 8.6-mm wavelengths are given. The temperatures reported for the planets at 3.1-mm wavelength are higher than previous measurements in this wavelength range and change the interpretation of some planetary spectra. For Mercury, it is found that the mean brightness temperature is independent of wavelength and that a temperature-dependent thermal conductivity is not required to match the observations. In the case of Mars, the spectrum is shown to rise in the millimeter region, as simple models predict. For Jupiter, the need to recalculate the spectrum with recent models is demonstrated. The flux density scale proposed by Dent (1972) has been revised according to a more accurate determination of the millimeter brightness temperature of Jupiter.

  14. System performance advances of 18-mm and 16-mm subminiature image intensifier sensors

    NASA Astrophysics Data System (ADS)

    Thomas, Nils I.

    2000-11-01

    Night vision system design has been centered aroudn the An/AVS-6 and AN/PVS-7 night vision goggle systems for the past 20 years. Goggle performance has improved during this time through increased performance of the image intensifier sensor, primarily the Omni IV sensor from ITT Industries Night Vision. Most of this improvement has been at the optimal light level (1E-3 fc scene illumination). Recent advances in image sensor performance from the filmless Generation (Gen) IV sensors has increased the low light level performance of night vision devices from 0.3 cy/mr to 0.7 cy/mr. In addition, sensor packaging design requirements have forced night vision sensor manufactures to design light weight, small volume sensors. ITT recently has designed such a sensor in a 16-mm format. This sensor if 50% lighter, up to 50% shorter, and has design features that simplify the objective lens design. New night vision goggles have been, and are being, designed which reduce the perceived head-supported weight. This paper presents signal-to-noise ratio, halo, and other film-less sensor data and similar 16-mm subminiature sensor data. The resulting system performance data will be described. Finally, the system design improvements and relationships with the subminiature 16-mm subminiature sensor will be given.

  15. Assessing the performance of the MM/PBSA and MM/GBSA methods: I. The accuracy of binding free energy calculations based on molecular dynamics simulations

    PubMed Central

    Hou, Tingjun; Wang, Junmei; Li, Youyong; Wang, Wei

    2011-01-01

    The Molecular Mechanics/Poisson Boltzmann Surface Area (MM/PBSA) and the Molecular Mechanics/Generalized Born Surface Area (MM/GBSA) methods calculate binding free energies for macromolecules by combining molecular mechanics calculations and continuum solvation models. To systematically evaluate the performance of these methods, we report here an extensive study of 59 ligands interacting with six different proteins. First, we explored the effects of the length of the molecular dynamics (MD) simulation, ranging from 400 to 4800 ps, and the solute dielectric constant (1, 2 or 4) to the binding free energies predicted by MM/PBSA. The following three important conclusions could be observed: (1). MD simulation lengths have obvious impact on the predictions, and longer MD simulations are not always necessary to achieve better predictions; (2). The predictions are quite sensitive to solute dielectric constant, and this parameter should be carefully determined according to the characteristics of the protein/ligand binding interface; (3). Conformational entropy showed large fluctuations in MD trajectories and a large number of snapshots are necessary to achieve stable predictions. Next, we evaluated the accuracy of the binding free energies calculated by three Generalized Born (GB) models. We found that the GB model developed by Onufriev and Case was the most successful model in ranking the binding affinities of the studied inhibitors. Finally, we evaluated the performance of MM/GBSA and MM/PBSA in predicting binding free energies. Our results showed that MM/PBSA performed better in calculating absolute, but not necessarily relative, binding free energies than MM/GBSA. Considering its computational efficiency, MM/GBSA can serve as a powerful tool in drug design, where correct ranking of inhibitors is often emphasized. PMID:21117705

  16. DUAL FREQUENCY RESONATOR FOR 1.2 GHZ EPR/16.2 MHZ NMR CO-IMAGING

    PubMed Central

    Petryakov, Sergey; Samouilov, Alexandre; Kesselring, Eric; Caia, George L.; Sun, Ziqi; Zweier, Jay L.

    2010-01-01

    The development of a dual frequency resonator that enables both EPR and proton NMR imaging within the same resonator, magnet and gradient system is described. A novel design allows the same resonator to perform both EPR and proton NMR operation without moving resonator cables or switches. The resonator is capable of working at frequencies of 16.18 MHz for proton NMR and 1.2 GHz for EPR and is optimized for isolated rat heart experiments, measuring 22 mm in inner diameter and 19 mm in length. In EPR mode, the resonator functions as a one loop two gap resonator, electrically coupled through a half wavelength inverter. In NMR mode, it functions a single turn coil. Using the same loop for both modalities maximizes filling factor at both frequencies. Placing the tuning and switching controls away from the resonator prevents any inadvertent movement that would cause errors of EPR and NMR co-imaging registration. The resonator enabled good quality EPR and proton MRI of isolated rat hearts with precise registration. PMID:20434379

  17. Optical properties of plastically bent large-diameter sapphire fiber tips for laser tissue ablations

    NASA Astrophysics Data System (ADS)

    Tong, Limin

    2000-10-01

    Aiming to facilitate laser surgery applications, six 0.75mm- diameter 90mm-length sapphire fiber tips were plastically bent by means of CO2 lasers with bending radii from 1.7mm to 3.6mm and bending angles of 15-120 degree(s). The average bending loss caused by the bending process of the tips is about 0.03dB with the minimum loss less than 0.02dB, the damage thresholds of these tips are higher than 160MW/cm2 for Nd:YAG laser pulses at 1.06micrometers and 2MW/cm2 for CuBr laser pulses at 510.6nm. Satisfactory optical properties of these sapphire fiber tips show that they are promising for use in laser surgery applications such as tissue ablations. 16

  18. Thirty-centimeter-diameter ion milling source

    NASA Technical Reports Server (NTRS)

    Robinson, R. S.

    1978-01-01

    A 30-cm beam diameter ion source has been designed and fabricated for micromachining and sputtering applications. An argon ion current density of 1 mA/cu cm at 500 eV ion energy was selected as a design operating condition. The completed ion source met the design criteria at this operating condition with a uniform and well-collimated beam having an average variation in current density of + or - 5% over the center of 20 cm of the beam. This ion source has a multipole magnetic field that employs permanent magnets between permeable pole pieces. Langmuir probe surveys of the source plasma support the design concepts of a multipole field and a circumferential cathode to enhance plasma uniformity.

  19. Development of fine diameter mullite fiber

    NASA Technical Reports Server (NTRS)

    Long, W. G.

    1974-01-01

    Results are presented of a program to develop and evaluate mullite fiber with a mean diameter under two microns. The two micron fiber is produced by a blowing process at room temperature from a low viscosity (10-25 poise) solution. The blown fiber was evaluated for dimensional stability in thermal cycling to 1371 C, and was equivalent to the 5 micron spun B and W mullite fiber. An additive study was conducted to evaluate substitutes for the boron. Three levels of chromium, lithium fluoride, and magnesium were added to the standard composition in place of boron and the fiber produced was evaluated for chemical and dimensional stability in thermal cycling to 1371 C. The magnesium was the most chemically stable, but the chrome additive imparted the best dimensional stability.

  20. Fire protection covering for small diameter missiles

    NASA Technical Reports Server (NTRS)

    Riccitiello, S. R.; Sawko, P. M. (Inventor)

    1979-01-01

    Flexible intumescent protection sheeting of unusually uniform thickness were prepared from epoxy-polysulfide compositions, containing microfibers and the ammonium salt of 1,4-nitroaniline-2-sulfonic acid, as disclosed in U.S. Pat. No. 3,663,464, except that an ammonium salt particle size in the order of 5 to 8 microns and a fiber size of about 1/128th inch in length and 3 to 5 microns in diameter were found critical to obtain the required density of 1.46 to 1.50 g/cc. The insulation sheeting was prepared by a continuous process involving vacuum mixing, calendering, and curing under very strict conditions which depend to some extent upon the thickness of the sheet produced.

  1. Granulation, Irradiance and Diameter Solar Variations

    NASA Astrophysics Data System (ADS)

    Humberto Andrei, Alexandre; Calderari Boscardin, Sergio; Lousada Penna, Jucira; Reis Neto, Eugenio

    2015-08-01

    Though granulation forms the very face of sun’s photosphere, there are no long term registers of it. Observational and computational hardships to define and follow such highly variable “face” have so far prevented the realization of those registers. However, in recent years a large, coherent body of white light images became available. We retrieved white light, full solar disk images from the BBSO, to a total of 1104 treated ones and 1245 treated and compensated for limb darkening ones. The time coverage extends from the year 2000 to 2005, thus covering the rise and fall of the solar cycle 23. For the analysis, only the central 0.35R portion of the Sun was considered. The central portion was then divided into 100 subsectors, to average and discard the deviant results. The analysis goal is to derive the long term behavior of the photosphere granulation, in broad statistical sense. Three statistics were this way calculated: the standard deviation of the counts (that answers to the grains size); the counts difference between the maximum and minimum tenths (that answers to the grains brightness); the degree of the best fit polynomial along lines and columns (that answers to the grains numbers). According to the statistics, there is no significant variation in the number of grains. The grains sizes are the largest by the solar maximum, in excellent agreement with the maximum of the measured diameter. The grains brightness, on the contrary, is minimum at the solar maximum, and again an excellent agreement is verified with the maximum of the measured diameter.

  2. SAFT 4{1/2} inch nickel hydrogen battery cells

    SciTech Connect

    Duquesne, D.; Lacout, B.; Sennet, A.

    1995-12-31

    SAFT Advanced Batteries has now produced over 400 high capacity 4{1/2} inch Nickel Hydrogen Battery Cells for flight programs. The 4.5 inch diameter, rabbit-ear cell design is designed to provide the anticipated energy required at the lowest practical weight. SAFT has incorporated into the design of the dry-powder nickel electrode, truly hermetic ceramic to metal seals, qualified terminal feedthroughs, high reliability mechanical design, composite pure platinum negative electrode, and zircar separator, plus more than 25 years experience in aerospace nickel cell technology, resulting in a 4{1/2} inch configuration with the 3{1/2} inch cell design carryover heritage. General performance requirements for GEO missions that SAFT cells meet are 15 years in orbit lifetime, 80% DOD, low mass to energy ratios, and flexible capacity by modifying number of electrodes in the stack. This design is qualified for geostationary orbits based on SAFT`s 3{1/2} inch qualification heritage, design verification, and cycling performed by customer Space Systems/LORAL in support of the INTELSAT VIIA and N-STAR flight programs.

  3. Fabrication and characterization of small-diameter vascular prostheses.

    PubMed

    Kowligi, R R; von Maltzahn, W W; Eberhart, R C

    1988-12-01

    We have developed a process to fabricate polyurethane vascular grafts of various dimensions and porosities in our laboratory. A primary feature of the presented fabrication technique is the ability to control surface porosity and roughness, and bulk mechanical properties. The method is based on the spray application of a fine mixture of polymer solution and nitrogen gas bubbles onto a lathe-mounted mandrel. The technique was successfully tested with Tecoflex, a linear segmented aliphatic polyurethane. Other urethane polymers can be used as well. Several polymer coats are applied in a semiautomated process, at the end of which the polymer coating is dried and the tube is slipped off the mandrel. It is the purpose of this paper to describe the fabrication process and present results of the evaluation of grafts. Wall structure was evaluated using scanning electron microscopy and compliance was measured in a specially designed testing apparatus. We developed methods to quantify kink resistance and suture retention capacity of the grafts. These characteristics were correlated with graft fabrication variables: mandrel rpm, horizontal speed of the spray nozzle, gas and polymer solution flow rates. We were able to routinely produce 3-6-mm-ID grafts with 0.5-1.2-mm wall thickness and average bulk pore sizes of 10-250 microns; the wall porosity could be varied between 30 and 70%. Compliance values of the grafts were comparable with corresponding values of carotid and femoral arteries of dogs. PMID:3235462

  4. Imaging characteristics of an 8.8  mm long and 125  μm thick graded-index short multimode fiber probe.

    PubMed

    Sato, Manabu; Shouji, Kou; Saito, Daisuke; Nishidate, Izumi

    2016-04-20

    We demonstrated the feasibility of an ultrathin imaging probe with a 50-μm core diameter, a 125 μm total diameter, and an 8.8 mm length, which is a typical graded-index multimode fiber for optical communications. We used an ABCD matrix to analyze the imaging conditions and magnification, which corresponded closely to the measured results. The lateral resolution was calculated at 1.2 μm with a wavelength of 730 nm, which reflects the image test pattern where a period of 4.38 μm was measured with a wavelength of 730 nm. In the numerical aperture of the objective lens, we experimentally evaluated the tradeoff between the magnification and the coupling efficiency. At four wavelengths of 540 nm, 632 nm, 730 nm, and 852 nm, the contrast and signal intensity versus the wavelength were investigated to show that the contrast at 632 and 730 nm is relatively high. By using a thin random phase screen model, we explained that as the wavelength decreases the greater the decrease in the optical transfer function at higher spatial frequencies. Using a 635 nm LED light source, we imaged the surfaces of chicken tendons in contact and the surface roughness was visible. PMID:27140102

  5. Attached cavitation at a small diameter ultrasonic horn tip

    NASA Astrophysics Data System (ADS)

    Žnidarčič, Anton; Mettin, Robert; Cairós, Carlos; Dular, Matevž

    2014-02-01

    Ultrasonic horn transducers are frequently used in applications of acoustic cavitation in liquids, for instance, for cell disruption or sonochemical reactions. They are operated typically in the frequency range up to about 50 kHz and have tip diameters from some mm to several cm. It has been observed that if the horn tip is sufficiently small and driven at high amplitude, cavitation is very strong, and the tip can be covered entirely by the gas/vapor phase for longer time intervals. A peculiar dynamics of the attached cavity can emerge with expansion and collapse at a self-generated frequency in the subharmonic range, i.e., below the acoustic driving frequency. Here, we present a systematic study of the cavitation dynamics in water at a 20 kHz horn tip of 3 mm diameter. The system was investigated by high-speed imaging with simultaneous recording of the acoustic emissions. Measurements were performed under variation of acoustic power, air saturation, viscosity, surface tension, and temperature of the liquid. Our findings show that the liquid properties play no significant role in the dynamics of the attached cavitation at the small ultrasonic horn. Also the variation of the experimental geometry, within a certain range, did not change the dynamics. We believe that the main two reasons for the peculiar dynamics of cavitation on a small ultrasonic horn are the higher energy density on a small tip and the inability of the big tip to "wash" away the gaseous bubbles. Calculation of the somewhat adapted Strouhal number revealed that, similar to the hydrodynamic cavitation, values which are relatively low characterize slow cavitation structure dynamics. In cases where the cavitation follows the driving frequency this value lies much higher - probably at Str > 20. In the spirit to distinguish the observed phenomenon with other cavitation dynamics at ultrasonic transducer surfaces, we suggest to term the observed phenomenon of attached cavities partly covering the full horn

  6. Management of anterior caliceal stones >15 mm.

    PubMed

    El-Shazly, M; Aziz, M; Omar, M; Al-Hunaidi, O; El-Nahas, A R

    2016-08-01

    Anterior caliceal stones represent a challenge to endourologist to select the best modality of management with the least morbidity. To study different treatment modalities of management of anterior caliceal stones >15 mm. It is an observational prospective study of patients with anterior caliceal stones more than 15 mm. Inclusion criteria were patients with isolated anterior caliceal stones, or branched anterior caliceal stones with posterior caliceal extension. Patients were evaluated using non-contrast CT preoperatively. They were divided into three groups: group 1 underwent PCNL through posterior caliceal puncture in cases with wide anterior calyx infundibulum or obtuse infundibulopelvic pelvic, group 2 underwent PCNL through anterior caliceal access in cases with narrow infundibulum or acute infundibulopelvic angel and group 3 underwent flexible ureteroscopy and laser lithotripsy. Intraoperative and postoperative findings were recorded and compared. Eighty eight patients were included in this study, Group 1 (44 patients) group 2 (28 patients), and group 3 (16 patients). Operative time was not significantly different across the three groups (68 ± 11.5, 72 ± 9 and 74 ± 11 min in group 1, 2 and 3, respectively, P = 0.053). Fluoroscopy time was significantly shorter for group 3 (2 ± 0.5 m, P = 0.0001) compared to group 1 and 2 (5.6 ± 4.6 and 4.5 ± 1.4 min), respectively. There were no significant differences in stone-free rates after initial treatment between the three groups; 84, 82, and 69 %, in groups 1, 2 and 3, respectively (P = 0.4). Postoperative hemoglobin drop was noted to be highest for group 2 and lowest for group 3 which was significantly different (1.7 ± 0.8, 2.2 ± 1.1, and 0.3 ± 0.3 g/dl, for patients in groups 1, 2 and 3 respectively, P = 0.0001). Group 2 showed the highest post-operative complication rate (21 %) in comparison to group 1 (11 %) and group 3 (6 %), however, differences were not statistically

  7. Effect of scuba-diving on optic nerve and sheath diameters

    PubMed Central

    Mehrpour, Masoud; Shams-Hosseini, Narges Sadat; Rezaali, Saeed

    2014-01-01

    Background: There is not any data available about the effect of high bar pressure condition on intracranial pressure. In this study, the effect of diving on the optic nerve and sheath diameters as non-invasive markers of intracranial pressure has been investigated. Methods: Twenty professional male divers from twenty one volunteers were chosen for this cross-sectional study. Only one person who had a history of barotraumas was excluded. Each diver then completed a questionnaire on demographic data, medical and diving history. Nineteen other volunteers were selected to represent a control group. A 10-MHz linear ultrasonic probe was used to measure the optic nerve sheath diameters of both eyes in closed and supine position and its relationship with diving history of divers was determined. Results: It was found that divers have a higher mean optic nerve sheath diameter compared to the normal population as previously reported by other studies. The mean diameter of the left and right optic nerve sheaths were 6.4±0.7, 6.5±0.9 mm respectively and a significant relationship between optic nerve sheath diameter and diving history was found. Conclusion: Results showed that divers have a higher optic nerve diameter than the general population. However, our result cannot yet be considered as a marker of intracranial pressure in divers as it was conducted on an limited number of subjects and so a bigger study should be undertaken for this purpose. PMID:25664290

  8. Tissue engineered small-diameter vascular grafts.

    PubMed

    Schmedlen, Rachael H; Elbjeirami, Wafa M; Gobin, Andrea S; West, Jennifer L

    2003-10-01

    Arterial occlusive disease remains the leading cause of death in western countries and often requires vascular reconstructive surgery. The limited supply of suitable small-diameter vascular grafts has led to the development of tissue engineered blood vessel substitutes. Many different approaches have been examined, including natural scaffolds containing one or more ECM proteins and degradable polymeric scaffolds. For optimal graft development, many efforts have modified the culture environment to enhance ECM synthesis and organization using bioreactors under physiologic conditions and biochemical supplements. In the past couple of decades, a great deal of progress on TEVGs has been made. Many challenges remain and are being addressed, particularly with regard to the prevention of thrombosis and the improvement of graft mechanical properties. To develop a patent TEVG that grossly resembles native tissue, required culture times in most studies exceed 8 weeks. Even with further advances in the field, TEVGs will likely not be used in emergency situations because of the time necessary to allow for cell expansion, ECM production and organization, and attainment of desired mechanical strength. Furthermore, TEVGs will probably require the use of autologous tissue to prevent an immunogenic response, unless advances in immune acceptance render allogenic and xenogenic tissue use feasible. TEVGs have not yet been subjected to clinical trials, which will determine the efficacy of such grafts in the long term. Finally, off-the-shelf availability and cost will become the biggest hurdles in the development of a feasible TEVG product. Although many obstacles exist in the effort to develop a small-diameter TEVG, the potential benefits of such an achievement are exciting. In the near future, a nonthrombogenic TEVG with sufficient mechanical strength may be developed for clinical trials. Such a graft will have the minimum characteristics of biological tissue necessary to remain patent

  9. Experimental and theoretical study of dryout in annular flow in small diameter channels

    NASA Astrophysics Data System (ADS)

    Mikielewicz, Dariusz; Gliński, Michał; Wajs, Jan

    2011-04-01

    In the paper the experimental analysis of dryout in small diameter channels is presented. The investigations were carried out in vertical pipes of internal diameter equal to 1.15 mm and 2.3 mm. Low-boiling point fluids such as SES36 and R123 were examined. The modern experimental techniques were applied to record liquid film dryout on the wall, among the others the infrared camera. On the basis of experimental data an empirical correlation for predictions of critical heat flux was proposed. It shows a good agreement with experimental data within the error band of 30%. Additionally, a unique approach to liquid film dryout modeling in annular flow was presented. It led to the development of the three-equation model based on consideration of liquid mass balance in the film, a two-phase mixture in the core and gas. The results of experimental validation of the model exhibit improvement in comparison to other models from literature.

  10. Analysis of the rail's settlement on the measurement of the diameter of wheel-set

    NASA Astrophysics Data System (ADS)

    Tan, Jianxiong; Shao, Shuangyun; Feng, Qibo

    2015-02-01

    In order to detect the diameter of a wheel-set online, the diameter was detected by using a laser displacement sensor and two eddy current displacement sensors at a speed of 15km/h. The weight of the wheel -set caused extrusion of the rail and changed the original measuring position, which had severe influence on the measuring results, so the influence of the deformation of the rail is analyzed and a compensation method based on the detection of the settlement of the rail is proposed. After compensation, the errors of the results are within +/-0.5mm and the standard deviation is 0.12mm. The measuring results showed that the compensation method satisfied with the need of measuring accuracy.

  11. The LLAMA 12 m mm/sub-mm radiotelescope in the Andes

    NASA Astrophysics Data System (ADS)

    Lepine, Jacques; Edemundo Arnal, Marcelo; de Graauw, Thijs; Abraham, Zulema; Gimenez de Castro, Guillermo; de Gouveia Dal Pino, Elisabete; Morras, Ricardo; Larrarte, Juan; Viramontes, José; Finger, Ricardo; Kooi, Jacob; Reeves, Rodrigo; Beaklini, Pedro

    2015-08-01

    LLAMA (Large Latin American Millimetric Array) is a joint Argentinean-Brazilian project of a 12m mm/sub-mm radio telescope similar to the APEX antenna, to be installed at a site at 4800 m altitude near San Antonio de Los Cobres in the Salta Province in Argentine, at 150 km from ALMA. The scientific cases for single dish and VLBI observations include black holes and accretion disks, the molecular evolution of interstellar clouds, the structure of the Galaxy, the formation of galaxies, and much more. The antenna was ordered to the company Vertex Antennentechnik in June 2014, and the construction is progressing quickly; it will be installed at the site in 2016. The radio telescope will be equipped with up to six receivers covering bands similar to those of ALMA. Cryostats with room for 3 cartridges, constructed by NAOJ (Tokyo,Japan), will be installed in each of the two Nasmyth cabins. Among the first receivers we will have an ALMA band 9 provided by NOVA (Groningen, Holland) and a band 5 from the Chalmers University (Sweden). Other receivers are still being discussed at the time of submission of this abstract,At high frequencies, VLBI observations at high frequencies could be made with ALMA, APEX and ASTE, and Northern radiotelescopes. In this way, LLAMA will be a seed for a Latin-American VLBI network.

  12. LED-based digital diameter measurement

    NASA Astrophysics Data System (ADS)

    Kleuver, Wolfram; Becker, Lothar

    1995-01-01

    This paper presents a new industrial sensor for measuring diameters of extreme thin objects. The system is divided in two parts. The first is the emitter and the second the receiver. It is possible to use this system for the automatic inspection of files and wires in the textile industries and wire works. Another application for the sensor is the control of production of chemical files in an extruder. Furthermore we can measure more than one object in the lightbeam because we get information not only about the dimensions also about the position of the objects in the beam. The innovation in this system is the using of a light emitting diode (LED) as emitter and the realization of a long distance of about two or more meters between the two sensorheads. The results of this development are a special kind of optical layout in the emitter to reduce the loss of intensity and minimize the divergence of the lightbeam. It is not necessary to develop an intensity distribution, which is equal over the complete width of the sensorhead. We can show that we have a better dynamic in the system with this feature. The experiments prove that we get the same resolution as a laserbeamsensor. Furthermore one advantage is the eye-safety.

  13. The 15 cm diameter ion thruster research

    NASA Technical Reports Server (NTRS)

    Wilbur, P. J.

    1974-01-01

    The startup reliability of a 15 cm diameter mercury bombardment ion thruster which employs a pulsed high voltage tickler electrode on the main and neutralizer cathodes is examined. Startup of the thruster is achieved 100% of the time on the main cathode and 98.7% of the time on the neutralizer cathode over a 3640 cycle test. The thruster was started from a 20 C initial condition and operated for an hour at a 600 mA beam current. An energy efficiency of 75% and a propellant utilization efficiency of 77% was achieved over the complete cycle. The effect of a single cusp magnetic field thruster length on its performance is discussed. Guidelines are formulated for the shaping of magnetic field lines in thrusters. A model describing double ion production in mercury discharges is presented. The production route is shown to occur through the single ionic ground state. Photographs of the interior of an operating-hollow cathode are presented. A cathode spot is shown to be present if the cathode is free of low work-function surfaces. The spot is observed if a low work-function oxide coating is applied to the cathode insert. Results show that low work-function oxide coatings tend to migrate during thruster operation.

  14. Large Circular Basin - 1300-km diameter

    NASA Technical Reports Server (NTRS)

    1974-01-01

    Close-up view of one-half of a 1300-km diameter circular basin the largest observed on Mercury. The other half is hidden beyond the terminator to the left. Hills and valleys extend in a radial fashion outward from the main ring. Interior of the large basin is completely flooded by plains materials; adjacent lowlands are also partially flooded and superimposed on the plains are bowl shaped craters. Wrinkle ridges are abundant on the plains materials. The area shown is 1008 miles (1600 km) from the top to the bottom of the picture. Sun's illumination is from the right. Blurred linear lines extending across the picture near bottom are missing data lines that have been filled in by the computer. Mariner 10 encountered Mercury on Friday, March 29th, 1974, passing the planet on the darkside 431 miles (690-km) from the surface.

    The Mariner 10 mission, managed by the Jet Propulsion Laboratory for NASA's Office of Space Science, explored Venus in February 1974 on the way to three encounters with Mercury-in March and September 1974 and in March 1975. The spacecraft took more than 7,000 photos of Mercury, Venus, the Earth and the Moon.

    NOTE: This image was scanned from physical media.

  15. Optical design and evaluation of a 4 mm cost-effective ultra-high-definition arthroscope

    PubMed Central

    Cheng, Dewen; Wang, Yongtian; Yu, Lu; Liu, Xiaohua

    2014-01-01

    High definition and magnification rigid endoscope plays an important role in modern minimally invasive medical surgery and diagnosis. In this paper, we present the design and evaluation methods of a high definition rigid endoscope, specifically an arthroscope, with a large depth of field (DOF). The incident heights and exit angles of the sampled rays on the relay lens are controlled during the optimization process to ensure an effective field view (70°) and a normal ray path within the limited lens diameter of 2.7 mm. The lens is set up as a multi-configuration system with two extreme and one middle object distances to cover a large DOF. As a result, an entrance pupil of 0.3 mm is achieved for the first time, to bring the theoretical resolution to 23.1 lps/mm in the object space at a working distance of 20 mm, with the wavelength of 0.532 um. The modulation transfer function (MTF) curves approach diffraction limit, and the values are all higher than 0.3 at 160 line pairs/mm (lps/mm) in the image space. Meanwhile, stray light caused by total internal reflection on the inner wall of the rod lenses and the objective lens is eliminated. The measured resolution in the object space at a 20 mm working distance is 22.3 lps/mm, and test results show that other performance characteristics also fulfill design requirements. The relay lenses are designed with only one type of the spacer and two types of lenses to greatly reduce the fabrication and assembly cost. The design method has important research and application values for lens systems used in modern minimally invasive medical surgery and industrial non-destructive testing area. PMID:25136495

  16. Pulse height tests of a large diameter fast LaBr₃:Ce scintillation detector.

    PubMed

    Naqvi, A A; Khiari, F Z; Maslehuddin, M; Gondal, M A; Al-Amoudi, O S B; Ukashat, M S; Ilyas, A M; Liadi, F A; Isab, A A; Khateeb-ur Rehman; Raashid, M; Dastageer, M A

    2015-10-01

    The pulse height response of a large diameter fast 100 mm × 100 mm LaBr3:Ce detector was measured for 0.1-10 MeV gamma-rays. The detector has a claimed time resolution of 608 ps for 511 keV gamma rays, but has relatively poor energy resolution due to the characteristics of its fast photomultiplier. The detector pulse height response was measured for gamma rays from cobalt, cesium, and bismuth radioisotope sources as well as prompt gamma rays from thermal neutron capture in water samples contaminated with mercury (3.1 wt%), boron (2.5 wt%), cadmium (0.25 wt%), chromium (52 wt%), and nickel (22 wt%) compounds. The energy resolution of the detector was determined from full width at half maximum (FWHM) of element-characteristic gamma ray peaks in the pulse height spectrum associated with the element present in the contaminated water sample. The measured energy resolution of the 100 mm × 100 mm detector varies from 12.7±0.2% to 1.9±0.1% for 0.1 to 10 MeV gamma rays, respectively. The graph showing the energy resolution ΔE/E(%) versus 1/√Eγ was fitted with a linear function to study the detector light collection from the slope of the curve. The slope of the present 100 mm × 100 mm detector is almost twice as large as the slope of a similar curve of previously published data for a 89 mm × 203 mm LaBr3:Ce detector. This indicates almost two times poorer light collection in the 100 mm × 100 mm detector as compared to the other detector. PMID:26207950

  17. [Modeling formation of aerobic granule and influence of hydrodynamic shear forces on granule diameter].

    PubMed

    Dong, Feng; Zhang, Han-Min; Yang, Feng-Lin

    2012-01-01

    A one-dimension aerobic granule mathematical model was established, basing on mathematical biofilm model and activated sludge model. The model was used to simulate simple aerobic granule process such as nutrients removal, granule diameter evolution, cycle performance as well as depth profiles of DO and biomass. The effluent NH4(+) -N concentration decreased as the modeling processed. The simulation effluent NO3(-)-N concentration decreased to 3 mg x L(-1) as the granules grew. While the granule diameter increased from 1.1 mm on day 30 to 2.5 mm on day 100, the TN removal efficiency increased from less than 10% to 91%. The denitrification capacity was believed to enhance because the anoxic zone would be enlarged with the increasing granule diameter. The simultaneous nitrification and denitrification occurred inside the big aerobic granules. The oxygen permeating depth increased with the consumption of substrate. It was about 100-200 microm at the beginning of the aeration phase, and it turned to near 800 microm at the end of reaction. The autotrophs (AOB and NOB) were mostly located at the out layer where the DO concentration was high. The heterotrophic bacteria were distributed through the whole granule. As hydrodynamic shear coefficient k(de) increased from 0.25 (m x d)(-1) to 5 (m x d)(-1), the granule diameter under steady state decreased form 3.5 mm to 1.8 mm. The granule size under the dynamic steady-state decreased with the increasing hydrodynamic shear force. The granule size could be controlled by adjusting aeration intensity. PMID:22452208

  18. Relation of Blood Pressure to Retinal Vessel Diameter in Type 1 Diabetes Mellitus

    PubMed Central

    Klein, Ronald; Myers, Chelsea E.; Klein, Barbara E. K.; Zinman, Bernard; Gardiner, Robert; Suissa, Samy; Sinaiko, Alan R.; Donnelly, Sandra M.; Goodyer, Paul; Strand, Trudy; Mauer, Michael

    2009-01-01

    Objective To examine the relationship of blood pressure (BP) and use of angiotensin receptor blocker (ARB) or angiotensin converting enzyme inhibitor (ACEI) to retinal vessel diameter in normotensive, normoalbuminuric persons with type 1 diabetes mellitus (T1DM). Design Randomized controlled clinical trial. Participants Persons with T1DM and gradable fundus photographs both at baseline (n=147) and 5-year follow-up (n=124). Methods Clinic and 24-hour ambulatory BPs (ABP) were measured. Retinal arteriolar and venular diameters were measured using a computer-assisted technique. Individual arteriolar and venular measurements were combined into summary indices that reflect the average retinal arteriolar (central retinal arteriolar equivalent [CRAE]) and venular (central retinal venular equivalent [CRVE]) diameter of an eye, respectively. Main Outcome Measures CRAE and CRVE. Results While controlling for age, study site, glycosylated hemoglobin and ambulatory pulse rate, daytime ambulatory systolic (-0.29 μm effect per 1mmHg, P=.02) and daytime ambulatory diastolic (-0.44 μm effect per 1mmHg, P=.04), nighttime ambulatory systolic (-0.27 μm effect per 1mmHg, P=.03), and 24-hour ambulatory systolic BP (-0.31 μm effect per 1mmHg, P=.03) were cross-sectionally associated with a smaller CRAE. While controlling for age, study site, glycosylated hemoglobin, ambulatory pulse rate and baseline CRAE, no BP measure was associated with a change in CRAE or CRVE over 5 years of follow-up. Treatment with losartan or enalapril was not associated with a statistically significant change in CRAE or CRVE. Conclusions ACEI or ARB therapy does not affect retinal arteriolar or venular diameter in normotensive persons with T1DM. PMID:20142543

  19. Slip flow through colloidal crystals of varying particle diameter.

    PubMed

    Rogers, Benjamin J; Wirth, Mary J

    2013-01-22

    Slip flow of water through silica colloidal crystals was investigated experimentally for eight different particle diameters, which have hydraulic channel radii ranging from 15 to 800 nm. The particle surfaces were silylated to be low in energy, with a water contact angle of 83°, as determined for a silylated flat surface. Flow rates through centimeter lengths of colloidal crystal were measured using a commercial liquid chromatograph for accurate comparisons of water and toluene flow rates using pressure gradients as high as 10(10) Pa/m. Toluene exhibited no-slip Hagen-Poiseuille flow for all hydraulic channel radii. For water, the slip flow enhancement as a function of hydraulic channel radius was described well by the expected slip flow correction for Hagen-Poiseuille flow, and the data revealed a constant slip length of 63 ± 3 nm. A flow enhancement of 20 ± 2 was observed for the smallest hydraulic channel radius of 15 nm. The amount of slip flow was found to be independent of shear rate over a range of fluid velocities from 0.7 to 5.8 mm/s. The results support the applicability of the slip flow correction for channel radii as small as 15 nm. The work demonstrates that packed beds of submicrometer particles enable slip flow to be employed for high-volume flow rates. PMID:23237590

  20. Slip Flow through Colloidal Crystals of Varying Particle Diameter

    PubMed Central

    Rogers, Benjamin J.; Wirth, Mary J.

    2012-01-01

    Slip flow of water through silica colloidal crystals was investigated experimentally for 8 different particle diameters, which have hydraulic channel radii ranging from 15 nm to 800 nm. The particle surfaces were silylated to be low in energy, with a water contact angle of 83°, as determined for a silylated flat surface. Flow rates through centimeter lengths of colloidal crystal were measured using a commercial liquid chromatograph for accurate comparisons of water and toluene flow rates using pressure gradients as high as 1010 Pa/m. Toluene exhibited no-slip Hagen-Poiseuille flow for all hydraulic channel radii. For water, the slip flow enhancement as a function of hydraulic channel radius was described well by the expected slip flow correction for Hagen-Poiseuille flow, and the data revealed a constant slip length of 63±3 nm. A flow enhancement of 20±2 was observed for the smallest hydraulic channel radius of 15 nm. The amount of slip flow was found to be independent of shear rate over a range of fluid velocities from 0.7 to 5.8 mm/s. The results support the applicability of the slip flow correction for channel radii as small as 15 nm. The work demonstrates that packed beds of submicrometer particles enable slip flow to be employed for high volume flow rates. PMID:23237590

  1. Teaching Evolutionary Mechanisms: Genetic Drift and M&M's.

    ERIC Educational Resources Information Center

    Staub, Nancy L.

    2002-01-01

    Describes a classroom activity that teaches the mechanism of genetic drift to undergraduates. Illustrates a number of concepts that are critical in developing evolution literacy by sampling M&M milk chocolate candies. (MM)

  2. Use of the Platelet Count/Spleen Diameter Ratio for the Noninvasive Diagnosis of Esophageal Varices in Patients with Schistosomiasis

    PubMed Central

    Agha, Adnan; Abdulhadi, Mamdouh M.; Marenco, Simona; Bella, Abdelhaleem; AlSaudi, Dib; El-Haddad, Ahmed; Inferrera, Simona; Savarino, Vincenzo; Giannini, Edoardo G.

    2011-01-01

    Background/Aim: In patients with liver cirrhosis, the platelet count/spleen diameter ratio has been validated as a parameter for the noninvasive diagnosis of esophageal varices. Schistosoma infection is a frequent cause of portal hypertension in Middle Eastern countries, and is associated with the development of esophageal varices. In this study we aimed to evaluate the platelet count/spleen diameter ratio as a noninvasive tool for the prediction of the presence of esophageal varices in patients with schistosoma-related chronic liver disease. Patients and Methods: Forty-three patients with hepatosplenic schistosomiasis underwent upper digestive endoscopy to check for the presence of esophageal varices. Furthermore, all patients underwent abdominal ultrasonography, and maximum spleen diameter (in mm) was measured. The platelet count/spleen diameter ratio was calculated in all patients. Results: Esophageal varices were found in 31 patients (72%). Age and gender were not significantly different between patients with and without varices. In patients with varices, median platelet count (82,000/μL versus 172,000/μL, P < 0.0001) and platelet count/spleen diameter ratio (571 versus 1651, P < 0.0001) were significantly lower, while spleen diameter (147 mm versus 109 mm, P = 0.0006) was significantly larger. In multivariate analysis, the platelet count/spleen diameter ratio was the only parameter independently associated with the presence of varices (P < 0.0001). Conclusions: In this study we have validated the use of the platelet count/spleen diameter ratio for the noninvasive diagnosis of esophageal varices in patients with portal hypertension caused by schistosoma infection. In these patients, the platelet count/spleen diameter ratio might be used to allow better rationalization of medical resources and use of endoscopy. PMID:21912056

  3. Growth and characterization of ferroelectric Pb(Sc1/2Nb1/2)O3 single crystals

    NASA Astrophysics Data System (ADS)

    Huo, Siqi; Bokov, Alexei A.; Paterson, Alisa; Ye, Zuo-Guang

    2015-10-01

    Single crystals of Pb(Sc1/2Nb1/2)O3 were grown by the high-temperature solution method using PbO + B2O3 as flux. The size of the as-grown crystals varies from 1 to 2 mm. X-ray diffraction indicates a pure perovskite phase without B-site ordering. Polarized light microscopy shows that the crystals are of rhombohedral symmetry at room temperature and become cubic at TC = 112 °C on heating. A ferroelectric-to-relaxor phase transition is verified at TC by dielectric spectroscopy. Frequency-dependent permittivity is observed in dielectric measurements, revealing relaxor behavior above TC. Poling the crystal at room temperature does not change TC, but suppresses the permittivity. Typical ferroelectric hysteresis loop is displayed at room temperature, indicating the ferroelectric nature of the rhombohedral phase.

  4. 44 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ..., appliances, services, or allowances therefor or to valuations, costs or accounting, or practices relating to... 44 Emergency Management and Assistance 1 2011-10-01 2011-10-01 false Definitions. 1.2 Section 1.2 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND...

  5. 24 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... participates in carrying out such program or activity (such as a redeveloper in the Urban Renewal Program... 24 Housing and Urban Development 1 2010-04-01 2010-04-01 false Definitions. 1.2 Section 1.2 Housing and Urban Development Office of the Secretary, Department of Housing and Urban...

  6. 24 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... participates in carrying out such program or activity (such as a redeveloper in the Urban Renewal Program... 24 Housing and Urban Development 1 2013-04-01 2013-04-01 false Definitions. 1.2 Section 1.2 Housing and Urban Development Office of the Secretary, Department of Housing and Urban...

  7. 24 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... participates in carrying out such program or activity (such as a redeveloper in the Urban Renewal Program... 24 Housing and Urban Development 1 2014-04-01 2014-04-01 false Definitions. 1.2 Section 1.2 Housing and Urban Development Office of the Secretary, Department of Housing and Urban...

  8. 24 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... participates in carrying out such program or activity (such as a redeveloper in the Urban Renewal Program... 24 Housing and Urban Development 1 2012-04-01 2012-04-01 false Definitions. 1.2 Section 1.2 Housing and Urban Development Office of the Secretary, Department of Housing and Urban...

  9. 24 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... participates in carrying out such program or activity (such as a redeveloper in the Urban Renewal Program... 24 Housing and Urban Development 1 2011-04-01 2011-04-01 false Definitions. 1.2 Section 1.2 Housing and Urban Development Office of the Secretary, Department of Housing and Urban...

  10. 44 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 44 Emergency Management and Assistance 1 2014-10-01 2014-10-01 false Definitions. 1.2 Section 1.2 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY... Emergency Management Agency. (e) Major rule means any regulation that is likely to result in: (1) An...

  11. 44 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 44 Emergency Management and Assistance 1 2012-10-01 2011-10-01 true Definitions. 1.2 Section 1.2 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY... Emergency Management Agency. (e) Major rule means any regulation that is likely to result in: (1) An...

  12. 44 CFR 1.2 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 44 Emergency Management and Assistance 1 2013-10-01 2013-10-01 false Definitions. 1.2 Section 1.2 Emergency Management and Assistance FEDERAL EMERGENCY MANAGEMENT AGENCY, DEPARTMENT OF HOMELAND SECURITY... Emergency Management Agency. (e) Major rule means any regulation that is likely to result in: (1) An...

  13. Effect of source diameter on helicon plasma thruster performance and its high power operation

    NASA Astrophysics Data System (ADS)

    Takahashi, Kazunori; Komuro, Atsushi; Ando, Akira

    2015-10-01

    Thrust imparted by a helicon plasma thruster is experimentally measured for two different diameter source tubes. The measurements demonstrate that the thrust-over-power of the helicon thruster can be increased by enlarging the source diameter. This result is qualitatively understood with a simple analysis connecting a global model in the source and a one-dimensional magnetic nozzle model, where the model does not include the magnetic field effect in the source and the cross-field diffusion effect in the magnetic nozzle. A mass flow rate of propellant argon and a magnetic field strength are experimentally surveyed; then the thrust of  ∼18 mN is obtained for the rf power of 1 kW, the 95 mm diameter source, and the largest solenoid current being tested, while the maximum thrust for the 26 mm diameter source is only 5 mN. Furthermore the rf power is increased up to  ∼6 kW and a thrust close to 60 mN is obtained.

  14. Estimation of local pulse wave velocity using arterial diameter waveforms: Experimental validation in sheep

    NASA Astrophysics Data System (ADS)

    Graf, S.; Craiem, D.; Barra, J. G.; Armentano, R. L.

    2011-12-01

    Increased arterial stiffness is associated with an increased risk of cardiovascular events. Estimation of arterial stiffness using local pulse wave velocity (PWV) promises to be very useful for noninvasive diagnosis of arteriosclerosis. In this work we estimated in an instrumented sheep, the local aortic pulse wave velocity using two sonomicrometry diameter sensors (separated 7.5 cm) according to the transit time method (PWVTT) with a sampling rate of 4 KHz. We simultaneously measured aortic pressure in order to determine from pressure-diameter loops (PWVPDLoop), the "true" local aortic pulse wave velocity. A pneumatic cuff occluder was implanted in the aorta in order to compare both methods under a wide range of pressure levels. Mean pressure values ranged from 47 to 101 mmHg and mean proximal diameter values from 12.5. to 15.2 mm. There were no significant differences between PWVTT and PWVPDLoop values (451±43 vs. 447±48 cm/s, p = ns, paired t-test). Both methods correlated significantly (R = 0.81, p<0.05). The mean difference between both methods was only -4±29 cm/s, whereas the range of the limits of agreement (mean ± 2 standard deviation) was -61 to +53 cm/s, showing no trend. In conclusion, the diameter waveforms transit time method was found to allow an accurate and precise estimation of the local aortic PWV.

  15. Colour of the nucleus as a marker of nuclear hardness, diameter and central thickness.

    PubMed

    Gullapalli, V K; Murthy, P R; Murthy, K R

    1995-12-01

    Hundred and thirty patients, aged above 40 years, with senile cataract were examined. Age and colour were selected as the probable preoperative indicators of nuclear hardness. The lens material collected after manual extracapsular extraction was washed and the nucleus isolated. The diameter and central thickness of the nucleus were measured; the mean diameter and mean central thickness were 7.13 mm +/- 0.76 and 3.05 mm +/- 0.48, respectively. The hardness of the nucleus was measured with a lens guillotine designed by us. Regression analysis was applied to the parameters measured and these were compared with the colour and age. The parameters measured had the following relationship: Colour vs hardness (r value = 0.7569) (p < 0.001) Colour vs diameter (r value = 0.3962) (p < 0.001) Colour vs central thickness (r value = 0.4785) (p < 0.001) Age vs hardness (r value = -0.0499) (p > 0.05) Age vs diameter (r value = 0.0987) (p > 0.05) Age vs central thickness (r value = 0.1700) (p > 0.05) The values showed that colour had a statistically significant relationship with all the 3 parameters (p < 0.001), while age had no significant relationship with the same parameters. The results indicated that colour can be used more reliably to predict physical characteristics of the cataractous lens nucleus, the preoperative knowledge of which would help the surgeon in planning small-incision surgery including phacoemulsification. PMID:8655196

  16. Femoral head diameter in subcapital fracture of the femur in Ibadan, Nigeria.

    PubMed

    Ogunlade, S O; Omololu, A B; Alonge, T O; Obajimi, M O

    2004-09-01

    Subcapital fracture of the femur is common in the elderly patients though the incidence is less in our environment than in the western world. Primary prosthetic replacement is the method of treatment in the majority of the patients. To facilitate this, a foreknowledge of the femoral head diameter is necessary. To determine the diameter of the femoral head and its magnification on radiograph among patients with hip fractures seen in South-West Nigeria, all patients with subcapital fracture of the neck of femur seen between March 1997 and February 2002 were included in the study. The femoral heads were measured on the radiographic film using a transparent ruler and after extraction of the femoral head during surgery using callipers. There were 25 patients in all, the mean age of patients was 73.2 years. Fall at home accounted for 70% of the cases. The femoral head diameter was between 42 mm and 50 mm in 92% of patients while magnification of femoral head diameter on radiograph was 10-14% in 92% of cases. The usaof 10-14% magnification of femoral head on radiograph would help the surgeon determine the size of prosthetic head before commencement of surgery. PMID:15819470

  17. Vein diameter after intraoperative dilatation with vessel probes as a predictor of success of hemodialysis arteriovenous fistulas

    PubMed Central

    Fila, Branko; Lovčić, Vesna; Sonicki, Zdenko; Magaš, Saša; Sudar-Magaš, Zrinka; Malovrh, Marko

    2014-01-01

    Background Vascular access is “the life line” for patients on chronic hemodialysis. The autogenous arteriovenous fistula provides the best access to the circulation because of low complication rate, long-term use, and lower cost, compared to arteriovenous graft and central venous catheter. The primary objective of this prospective study was to investigate the predictive value of vein diameter after intraoperative dilatation with vessel probes on hemodialysis fistula maturation. Material/Methods Ninety-three fistulas were performed by a single surgeon from February 1, 2006 to January 31, 2009. Intraoperative vein dilatation with vessel probes was attempted in all fistulas. Measurements of the feeding artery diameter, vein diameter and the increased vein diameter after intraoperative dilatation were performed and immediate failure, early patency, early failure, primary patency, and fistula survival outcomes were recorded during 48-month follow-up. Results Early failure occurred in 20% of fistulas and 70% matured sufficiently for cannulation. Variables with significant impact on the failure to mature by univariate analysis were: body-mass index (P=0.041), artery diameter (P<0.001), vein diameter (P=0.004), and vein diameter after dilatation (P=0.002). However, multivariate analysis showed that only body-mass index (P=0.038), artery diameter (P=0.001), and the diameter of the vein after dilatation (P=0.018) significantly affected maturation. In a group of 56 (60%) patients with vein diameter before dilatation ≤2 mm, among vessel characteristics found by multivariate analysis, only vein diameter after dilatation (P=0.004) significantly affected function. Conclusions Artery diameter and vein diameter after intraoperative dilatation with vessel probes were the main predictors of fistula function. PMID:24496387

  18. Effect of Diameter of Saphenous Vein on Stump Length after Radiofrequency Ablation for Varicose Vein

    PubMed Central

    Kim, Jusung; Cho, Sungsin; Joh, Jin Hyun; Ahn, Hyung-Joon; Park, Ho-Chul

    2015-01-01

    Purpose: Radiofrequency ablation (RFA) has gained popularity for treatment of varicose veins. The diameter of the saphenous vein should be considered before RFA because occlusion of the vein may differ depending on its diameter. Until now, however, there have been few data about the correlation between the diameter of the saphenous vein and the stump length after RFA. The purpose of our study was to investigate its correlation. Materials and Methods: A retrospective review was performed from prospectively collected data of RFA patients between March 2009 and December 2011. Preoperatively, the saphenous vein diameter was measured. Ablation was initiated 2 cm distal from the junction. Postoperatively, stump length was measured at 1 week and 6 months. After 2 years, we measured the length from the saphenofemoral junction to the leading point of occlusion for great saphenous vein, and length from the saphenopopliteal junction to the leading point of occlusion for small saphenous vein. The paired t-test, independent t-test, and correlation analysis were used for statistical analysis. P-value <0.05 was considered statistically significant. Results: During the study period, RFA was performed in 201 patients. Endovenous heat-induced thrombosis developed in 3 patients (1.5%). After 2 years, the stump length was obtained in 74 limbs. The mean diameter and stump length of the saphenous vein were 6.7±1.8 mm and 12.5±8.5 mm, respectively. Correlation analysis showed that the Pearson correlation coefficient of these factors was −0.017. Conclusion: There was no correlation between the diameter of saphenous vein and stump length. PMID:26719839

  19. Correlation between Central Venous Pressure and Inferior Vena Cava Sonographic Diameter; Determining the Best Anatomic Location

    PubMed Central

    Naghipour, Bahman; Faridaalaee, Gholamreza

    2016-01-01

    Introduction: The correlation of central venous pressure (CVP) with inferior vena cava (IVC) sonographic diameter has been reported in several studies. However, few studies have attempted to find the best anatomic location of measurement. Therefore, the purpose of this study was determining the best anatomic location to find precise correlation between CVP and IVC diameter using transesophageal echocardiography (TEE). Methods: In the present diagnostic accuracy study, patients in need of central venous catheterization and TEE were enrolled. Maximum diameter of IVC were measured during expiratory phase of respiratory cycle at the level of diaphragm, 2cm above the diaphragm and at the point of entry into the right atrium using SonoSite TEE device. CVP was measured using an electronic transducer connected to the central venous line. The best location for sonography was determined via calculating and comparing area under the receiver operating characteristics (ROC) curve (AUC). Results: 39 patients were enrolled (53.8% female). Mean CVP was 6.8 ± 1.4 mmHg and 25 (64.1%) patients had normal CVP, while 14 (35.9%) showed elevated CVP (> 6 mmHg). Evaluating AUC showed that IVC diameter (p = 0.01), aorta diameter (p = 0.01) and IVC / aorta ratio (p = 0.004) had acceptable correlation with CVP. Point of entry of IVC into the right atrium with AUC of 0.98 (95% CI: 0.95 – 1.00) was the location of highest correlation with CVP. Conclusion: Based on the present findings, the IVC sonographic diameter and IVC / aorta ratio had acceptable correlation with CVP at the level of IVC entry into the right atrium.

  20. Visualization study of enhanced flash boiling of R-22 with 5 mm steel and glass spheres

    SciTech Connect

    Nutter, D.W.; O`Neal, D.L.

    1998-10-01

    This paper presents the qualitative results and discussion from an experimental investigation of passive enhanced flash boiling of R-22 (an HCFC) from a small vessel. A bench-top experimental apparatus was used to conduct enhanced flash boiling tests with 5.0 mm diameter steel and glass spheres placed at the base of the glass vessel. Sixty-second experiments were conducted with initial refrigerant amounts of 0.23 kg and 0.68 (0.5 lbm and 1.5 lbm), exiting orifices of 1.59 mm and 5.56 mm in diameter (0.063 in. and 0.219 in.), and with an initial pressure of 840 kPa (122 psia). The experiments were designed to simulate the flash boiling process that occurs within the refrigerant accumulator of air-source heat pumps during the reverse-cycle defrost. Results from the visualization study include a complete description of the flashing process with added steel and glass spheres. It was also shown that the enhancement method significantly increased the rate of total vapor production by 24--55% when exposed to a rapid depressurization.

  1. Presenting a high accuracy Theta-Phi-style fiber-positioner prototype with a 15-mm pitch

    NASA Astrophysics Data System (ADS)

    Haeuser, Marco; Lang-Bardl, Florian; Richter, Josef; Hess, Hans-Joachim; Degwert, Adrian; Karasz, Adolf; Kosyra, Ralf; Hopp, Ulrich; Bender, Ralf

    2014-07-01

    We present a Θ - Φ-style fiber-positioner prototype, which will be controlled via the EMI-robust CAN-Bus. Our positioner points without iterations or a metrology system. Due to the overlapping patrol disc of 17.3 mm diameter, we reach a filling factor of 100 %. The positioners diameter is 14.6 mm, containing the control electronics on a contemporary PCB of 13.5 mm width. While moving, the power consumption does not lead to a significant rise in temperature. Given a mechanical reference point measured by stall detection, the absolute accuracy is 27 μm (1σ = 14 µm) and pointings are repeatable with 7 μm (1σ = 4 μm). Better positioning may be reachable with upcoming calibration.

  2. Instability of Reference Diameter in the Evaluation of Stenosis After Coronary Angioplasty: Percent Diameter Stenosis Overestimates Dilative Effects Due to Reference Diameter Reduction

    SciTech Connect

    Hirami, Ryouichi; Iwasaki, Kohichiro; Kusachi, Shozo; Murakami, Takashi; Hina, Kazuyoshi; Matano, Shigeru; Murakami, Masaaki; Kita, Toshimasa; Sakakibara, Noburu; Tsuji, Takao

    2000-03-15

    Purpose: To examine changes in the reference segment luminal diameter after coronary angioplasty.Methods: Sixty-one patients with stable angina pectoris or old myocardial infarction were examined. Coronary angiograms were recorded before coronary angioplasty (pre-angioplasty) and immediately after (post-angioplasty), as well as 3 months after. Artery diameters were measured on cine-film using quantitative coronary angiographic analysis.Results: The diameters of the proximal segment not involved in the balloon inflation and segments in the other artery did not change significantly after angioplasty, but the reference segment diameter significantly decreased (4.7%). More than 10% luminal reduction was observed in seven patients (11%) and more than 5% reduction was observed in 25 patients (41%). More than 5% underestimation of the stenosis was observed in 22 patients (36%) when the post-angioplasty reference diameter was used as the reference diameter, compared with when the pre-angioplasty measurement was used and more than 10% underestimation was observed in five patients (8%).Conclusion: This study indicated that evaluation by percent diameter stenosis, with the reference diameter from immediately after angioplasty, overestimates the dilative effects of coronary angioplasty, and that it is thus better to evaluate the efficacy of angioplasty using the absolute diameter in addition to percent luminal stenosis.

  3. Limitations on the Optical Tunability of Small Diameter Gold Nanoshells

    PubMed Central

    Rasch, Michael R.; Sokolov, Konstantin V.; Korgel, Brian A.

    2009-01-01

    Gold (Au) nanoshells were grown on silica nanoparticles with differing average diameters, ranging from 30 nm to 120 nm. Au nanoshells were also formed on silica spheres encapsulating 5 nm diameter magnetic iron oxide nanocrystals. The optical absorbance spectra of these Au nanoshells are reported. The plasmon resonance wavelengths of the smaller diameter nanoshells were significantly less tunable than those of the larger diameter nanoshells. This is due to a reduced range of accessible core-shell ratio—the geometric factor that determines the plasmon peak position—as the silica core diameter shrinks. The smaller diameter nanoshells were also found to be highly prone to aggregation, which broadens the plasmon absorption peak. Model calculations of dispersion stability as a function of silica core diameter reveal that smaller diameter Au shells exhibit more aggregation because of the size-dependence of the electrostatic double-layer potential. PMID:19711913

  4. Nineteen-Foot Diameter Explosively Driven Blast Simulator

    SciTech Connect

    VIGIL,MANUEL G.

    2001-07-01

    This report describes the 19-foot diameter blast tunnel at Sandia National Laboratories. The blast tunnel configuration consists of a 6 foot diameter by 200 foot long shock tube, a 6 foot diameter to 19 foot diameter conical expansion section that is 40 feet long, and a 19 foot diameter test section that is 65 feet long. Therefore, the total blast tunnel length is 305 feet. The development of this 19-foot diameter blast tunnel is presented. The small scale research test results using 4 inch by 8 inch diameter and 2 foot by 6 foot diameter shock tube facilities are included. Analytically predicted parameters are compared to experimentally measured blast tunnel parameters in this report. The blast tunnel parameters include distance, time, static, overpressure, stagnation pressure, dynamic pressure, reflected pressure, shock Mach number, flow Mach number, shock velocity, flow velocity, impulse, flow duration, etc. Shadowgraphs of the shock wave are included for the three different size blast tunnels.

  5. 40 CFR Table Mm-2 to Subpart Mm of... - Default Factors for Biomass-Based Fuels and Biomass

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 40 Protection of Environment 22 2012-07-01 2012-07-01 false Default Factors for Biomass-Based Fuels and Biomass MM Table MM-2 to Subpart MM of Part 98 Protection of Environment ENVIRONMENTAL... Biomass-Based Fuels and Biomass Biomass-based fuel and biomass Column A:Density (metric tons/bbl) Column...

  6. 40 CFR Table Mm-2 to Subpart Mm of... - Default Factors for Biomass-Based Fuels and Biomass

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 40 Protection of Environment 22 2013-07-01 2013-07-01 false Default Factors for Biomass-Based Fuels and Biomass MM Table MM-2 to Subpart MM of Part 98 Protection of Environment ENVIRONMENTAL... Biomass-Based Fuels and Biomass Biomass-based fuel and biomass Column A:Density (metric tons/bbl) Column...

  7. 40 CFR Table Mm-2 to Subpart Mm of... - Default Factors for Biomass-Based Fuels and Biomass

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 21 2014-07-01 2014-07-01 false Default Factors for Biomass-Based Fuels and Biomass MM Table MM-2 to Subpart MM of Part 98 Protection of Environment ENVIRONMENTAL... Biomass-Based Fuels and Biomass Biomass-based fuel and biomass Column A:Density (metric tons/bbl) Column...

  8. Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging

    PubMed Central

    Shirodkar, Chetan G.; Munta, Kartik; Rao, S. Manimala; Mahesh, M. Uma

    2015-01-01

    Background and Aims: Analysis to correlate the measurements of optic nerve sheath diameter (ONSD) obtained by using ultrasound to magnetic resonance imaging (MRI) techniques in order to establish the accuracy of ocular sonography as a noninvasive modality for detecting raised intracranial pressure (ICP). Materials and Methods: A prospective, observational study was performed in 100 cases of adult meningoencephalitis patients admitted to Intensive Care Unit in whom MRI was performed for neurodiagnosis. ONSD was measured in such patients, 3 mm behind the globe in each eye. A mean binocular ONSD >4.6 mm in female and 4.8 mm in male was taken as cut-off values for diagnosing raised ICP. This was compared with ONSD measured on T2-weighted MRI image measured 3 mm behind the globe. The reading obtained from both the methods were compared with Bland–Altman analysis for correlation and the findings were tabulated. Results: The mean ONSD values measured with ultrasonography (USG) and MRI for female were 5.48 ± 0.43 mm and 5.68 ± 0.44 mm and for male were 5.40 ± 0.37 mm and 5.56 ± 0.38 mm, respectively. The mean age of the female and male was 53.90 ± 17.84 and 56.06 ± 15.67 years, respectively. On comparing ultrasound with MRI-derived ONSD values, we found acceptable agreement between both methods for measurements at a depth of 3 mm (r = 0.02, P < 0.001). Conclusion: In our study, we have found a good correlation between ocular USG and MRI of ONSD. The study has shown agreement with the fact that ocular sonography can be used as a noninvasive tool for detecting raised ICP with accuracy. PMID:26321806

  9. A λ = 1.3 mm and 2 mm molecular line survey towards M 82

    NASA Astrophysics Data System (ADS)

    Aladro, R.; Martín, S.; Martín-Pintado, J.; Mauersberger, R.; Henkel, C.; Ocaña Flaquer, B.; Amo-Baladrón, M. A.

    2011-11-01

    Aims: We study the chemical complexity towards the central parts of the starburst galaxy M 82, and investigate the role of certain molecules as tracers of the physical processes in the galaxy circumnuclear region. Methods: We carried out a spectral line survey with the IRAM-30 m telescope towards the northeastern molecular lobe of M 82. It covers the frequency range between 129.8 GHz and 175.0 GHz in the 2 mm atmospheric window, and between 241.0 GHz and 260.0 GHz in the 1.3 mm atmospheric window. Results: Sixty-nine spectral features corresponding to 18 different molecular species are identified. In addition, three hydrogen recombination lines are detected. The species NO, H2S, H2CS, NH2CN, and CH3CN are detected for the first time in this galaxy. Assuming local thermodynamic equilibrium, we determine the column densities of all the detected molecules. We also calculate upper limits to the column densities of fourteen other important, but undetected, molecules, such as SiO, HNCO, or OCS. We compare the chemical composition of the two starburst galaxies M 82 and NGC 253. This comparison enables us to establish the chemical differences between the products of the strong photon-dominated regions driving the heating in M 82, and the large-scale shocks that influence the properties of the molecular clouds in the nucleus of NGC 253. Conclusions: Overall, both sources have different chemical compositions. Some key molecules highlight the different physical processes dominating both central regions. Examples include CH3CCH, c-C3H2, or CO+, the abundances of which are clearly higher in M 82 than in NGC 253, pointing at photodissociating regions. On the other hand, species such as CH2NH, NS, SiO, and HOCO+ have abundances of up to one order of magnitude higher in NGC 253 than in M 82. Appendix is available in electronic form at http://www.aanda.org

  10. Normal Proximal Coronary Artery Diameters in Adults from India as Assessed by Computed Tomography Angiography

    PubMed Central

    Mahadevappa, Manjappa; Math, Ravi

    2016-01-01

    Introduction The normative data of coronary artery size among Indians are sparse. It is often essential to know the coronary dimensions especially during interventions such as stenting to choose the appropriate size of the stent and to decide the very need for stenting. In current practice it is the luminal angiography which is most widely employed to assess the coronary artery size. However, luminal angiography is not very accurate in estimating the epicardial coronary artery size as it does not take into account the mural thickness of the arterial wall. Hence it is prudent to assess coronary artery size by other methods such as Computed Tomography (CT) coronary angiography, quantitative coronary angiogram, Magnetic Resonanace (MR) angiogram, etc. In this study we chose computed tomography as it demonstrates mural thickness along with lumen of the vessels and hence measures the diameter more accurately. Aim To establish normative data for diameters of the proximal coronary artery segments during life by using MDCT in a cohort of individuals without any structural heart disease. Materials and Methods Between October 2012 and April 2013, 168 consecutive patients who did not have any structural heart disease underwent CT coronary angiography for evaluation of Coronary Artery Disease (CAD) with atypical symptoms with low pretest probability. Patients who were found to have no coronary artery disease on CT-CAG were recruited in this study. The baseline clinical status and demographic data were obtained from the hospital records. Results In our study we found that the mean indexed diameter to BSA among females for LMCA 2.32±0.12mm, LAD 1.95±0.15mm, LCX 1.73±0.20mm and RCA 1.84±0.22mm. For males the values were LMCA 2.33±0.13mm, LAD 1.94±0.16mm, LCX 1.74±0.21mm, and RCA 1.79±0.20mm. These values are comparable to other studies. Conclusion We attempted to establish normative data for normal proximal coronary artery dimensions among South Indian population

  11. Extrusion of small-diameter, thin-wall tungsten tubing

    NASA Technical Reports Server (NTRS)

    Blankenship, C. P.; Gyorgak, C. A.

    1967-01-01

    Small-diameter, thin-wall seamless tubing of tungsten has been fabricated in lengths of up to 10 feet by hot extrusion over a floating mandrel. Extrusion of 0.50-inch-diameter tubing over 0.4-inch-diameter mandrels was accomplished at temperatures ranging from 3000 degrees to 4000 degrees F.

  12. Optimization of rod diameter in solid state lasers side pumped with multiple laser diode arrays

    NASA Technical Reports Server (NTRS)

    Sims, Newton, Jr.; Chamblee, Christyl M.; Barnes, Norman P.; Lockard, George E.; Cross, Patricia L.

    1992-01-01

    Results of a study to determine the optimum laser rod diameter for maximum output energy in a solid state neodymium laser transversely pumped with multiple laser diode arrays are reported here. Experiments were performed with 1.0 mm, 1.5 mm and 2.0 mm rod radii of both neodymium doped Y3Al5O12 (Nd:YAG) and La2Be2O5 (Nd:BeL) pumped with laser diode arrays having a maximum combined energy of 10.5 mJ. Equations were derived which predict the optimum rod radius and corresponding output mirror reflectivity for a given laser material and total pump energy. Predictions of the equations agreed well with the experiments for each of the laser materials which possessed significantly different laser properties from one another.

  13. Agreement between inferior vena cava diameter measurements by subxiphoid versus transhepatic views

    PubMed Central

    Kulkarni, Atul Prabhakar; Janarthanan, S.; Harish, M. M; Suhail, Siddique; Chaudhari, Harish; Agarwal, Vandana; Patil, Vijaya P.; Divatia, Jigeeshu V.

    2015-01-01

    Context: Correcting hypovolemia is extremely important. Central venous pressure measurement is often done to assess volume status. Measurement of inferior vena cava (IVC) is conventionally done in the subcostal view using ultrasonography. It may not be possible to obtain this view in all patients. Aims: We therefore evaluated the limits of agreement between the IVC diameter measurement and variation in subcostal and that by the lateral transhepatic view. Settings and Design: Prospective study in a tertiary care referral hospital intensive care unit. Subjects and Methods: After Institutional Ethics Committee approval and informed consent, we obtained 175 paired measurements of the IVC diameter and variation in both the views in adult mechanically ventilated patients. The measurements were carried out by experienced researchers. We then obtained the limits of agreement for minimum, maximum diameter, percentage variation of IVC in relation to respiration. Statistical Analysis Used: Bland–Altman's limits of agreement to get precision and bias. Results: The limits of agreement were wide for minimum and maximum IVC diameter with variation of as much as 4 mm in both directions. However, the limits of agreement were much narrower when the percentage variation in relation to respiration was plotted on the Bland–Altman plot. Conclusions: We conclude that when it is not possible to obtain the subcostal view, it is possible to use the lateral transhepatic view. However, using the percentage variation in IVC size is likely to be more reliable than the absolute diameter alone. It is possible to use both views interchangeably. PMID:26816446

  14. AC conductivity and relaxation mechanism in (Nd1/2Li1/2)(Fe1/2V1/2)O3 ceramics

    NASA Astrophysics Data System (ADS)

    Nath, Susmita; Barik, Subrat Kumar; Choudhary, R. N. P.

    2016-05-01

    In the present study we have synthesized polycrystalline sample of (Nd1/2Li1/2)(Fe1/2V1/2)O3 ceramic by a standard high-temperature solid-state reaction technique. Studies of dielectric and electrical properties of the compound have been carried out in a wide range of temperature (RT - 400 °C) and frequency (1kHz - 1MHz) using complex impedance spectroscopic technique. The imaginary vs. real component of the complex impedance plot (Nyquist plot) of the prepared sample exhibits the existence of grain, grain boundary contributions in the complex electrical parameters and negative temperature coefficient of resistance (NTCR) type behavior like semiconductor. Details study of ac conductivity plot reveals that the material obeys universal Jonscher's power law.

  15. Cisplatin inhibits MEK1/2

    PubMed Central

    Yamamoto, Tetsu; Tsigelny, Igor F.; Götz, Andreas W.; Howell, Stephen B.

    2015-01-01

    Cisplatin (cDDP) is known to bind to the CXXC motif of proteins containing a ferrodoxin-like fold but little is known about its ability to interact with other Cu-binding proteins. MEK1/2 has recently been identified as a Cu-dependent enzyme that does not contain a CXXC motif. We found that cDDP bound to and inhibited the activity of recombinant MEK1 with an IC50 of 0.28 μM and MEK1/2 in whole cells with an IC50 of 37.4 μM. The inhibition of MEK1/2 was relieved by both Cu+1 and Cu+2 in a concentration-dependent manner. cDDP did not inhibit the upstream pathways responsible for activating MEK1/2, and did not cause an acute depletion of cellular Cu that could account for the reduction in MEK1/2 activity. cDDP was found to bind MEK1/2 in whole cells and the extent of binding was augmented by supplementary Cu and reduced by Cu chelation. Molecular modeling predicts 3 Cu and cDDP binding sites and quantum chemistry calculations indicate that cDDP would be expected to displace Cu from each of these sites. We conclude that, at clinically relevant concentrations, cDDP binds to and inhibits MEK1/2 and that both the binding and inhibitory activity are related to its interaction with Cu bound to MEK1/2. This may provide the basis for useful interactions of cDDP with other drugs that inhibit MAPK pathway signaling. PMID:26155939

  16. A 1.2--Millimeter Broad--Band Polarimeter

    NASA Astrophysics Data System (ADS)

    Glenn, Jason; Walker, Christopher K.; Young, Erick T.

    1996-05-01

    We describe a 1.2--millimeter polarimeter to be used on the Steward Observatory and Max--Planck--Institut fur Radioastronomie 10--meter Submillimeter Telescope Observatory. The construction, performance parameters, and scientific purpose of the instrument are presented. The detector is a Ge bolometer with a Si absorber operated in a cavity cooled to 0.36 K by a liquid He(3) refrigerator. The bandpass has a central wavelength of 1.2 mm and a width of 0.3 mm. The system noise equivalent power is 1.5*E(-14) W Hz(-{1/2}) at 20 Hz. Polarimetric modulation is accomplished with a room temperature, rotating Rexolite half-wave plate. Unidirectional grooves provide the lambda /2 phase shift between the orthogonal senses of polarization. The polarization analyzer is a stationary, room temperature, unidirectional wire grid that transmits only one sense of polarization with 99% efficiency. The system polarimetric efficiency is 87% and the laboratory instrumental polarization is a well defined 3.7%. Detection of a 1% linear polarization is possible at the several sigma level. The primary scientific goal of this instrument is to probe the magnetic field orientations in the protostellar dust cores of molecular clouds. Non--spherical dust grains are aligned in the presence of a magnetic field resulting in linear polarization of the far--infrared thermal dust emission perpendicular to the magnetic field vector. Observed field orientations will be compared to protostellar molecular outflow orientations and magnetic fields on larger scales. With these comparisons we will assess the role of magnetic fields in cloud collapse and star formation.

  17. A λ 3 mm and 1 mm line survey toward the yellow hypergiant IRC +10420⋆

    PubMed Central

    Quintana-Lacaci, G.; Agúndez, M.; Cernicharo, J.; Bujarrabal, V.; Sánchez Contreras, C.; Castro-Carrizo, A.; Alcolea, J.

    2016-01-01

    Aims Our knowledge of the chemical properties of the circumstellar ejecta of the most massive evolved stars is particularly poor. We aim to study the chemical characteristics of the prototypical yellow hypergiant star, IRC +10420. For this purpose, we obtained full line surveys at 1 and 3 mm atmospheric windows. Methods We have identified 106 molecular emission lines from 22 molecular species. Approximately half of the molecules detected are N-bearing species, in particular HCN, HNC, CN, NO, NS, PN, and N2H+. We used rotational diagrams to derive the density and rotational temperature of the different molecular species detected. We introduced an iterative method that allows us to take moderate line opacities into account. Results We have found that IRC +10420 presents high abundances of the N-bearing molecules compared with O-rich evolved stars. This result supports the presence of a N-rich chemistry, expected for massive stars. Our analysis also suggests a decrease of the 12C/13C ratio from ≳ 7 to ~ 3.7 in the last 3800 years, which can be directly related to the nitrogen enrichment observed. In addition, we found that SiO emission presents a significant intensity decrease for high-J lines when compared with older observations. Radiative transfer modeling shows that this variation can be explained by a decrease in the infrared (IR) flux of the dust. The origin of this decrease might be an expansion of the dust shell or a lower stellar temperature due to the pulsation of the star. PMID:27458319

  18. Impact of Needle Diameter on Long-Term Dry Needling Treatment of Chronic Lumbar Myofascial Pain Syndrome

    PubMed Central

    Wang, Gang; Gao, Qian; Li, Jun; Tian, Yuling; Hou, Jingshan

    2016-01-01

    ABSTRACT Objective To investigate the impact of diameter of needles on the effect of dry needling treatment of chronic lumbar myofascial pain syndrome. Design Forty-eight patients with chronic lumbar myofascial pain syndrome were randomly allocated to 3 groups. They received dry needling with needles of diameter 0.25 (group A), 0.5 (group B), and 0.9 mm (group C). Visual analog scale evaluation and health survey were conducted at baseline and 3 months after the treatment. Results Visual analog scale scores were significantly different in all groups from baseline to 3 months. Visual analog scale scores at 3 months showed differences between group C and the other 2 groups. When baseline and 3 months after treatment (0 day and 3 months) in each of the 3 groups was compared, there was a difference between group C and group B. The Short Form (36) Health Survey scores from baseline to 3 months were different within the treatment groups. Conclusions Visual analog scale score evaluations at 3 months showed efficacy in all groups. Results of 3 months showed that efficacy of treatment with larger needles (0.9-mm diameter) was better than that of smaller ones (0.5-mm diameter). The Short Form (36) Health Survey scores at 3 months indicated that treatments with needles of varying diameters were all effective, and when the results of 3 months were compared, there was no difference between the 3 groups. PMID:27333534

  19. Aortic Intima-Media Thickness and Aortic Diameter in Small for Gestational Age and Growth Restricted Fetuses

    PubMed Central

    Gomez-Roig, M. Dolores; Mazarico, Edurne; Valladares, Esther; Guirado, Laura; Fernandez-Arias, Mireia; Vela, Antonio

    2015-01-01

    Objective The objective of this study is to measure aortic intima-media thickness (aIMT) and aortic diameter (AD) in appropriate for gestational age (AGA) fetuses, small for gestational age (SGA) fetuses, and intrauterine growth restricted (IUGR) fetuses. Methods Case-control study performed between June 2011 and June 2012. Forty-nine AGA fetuses, 40 SGA fetuses, and 35 IUGR fetuses underwent concomitant measurement of aIMT and AD at a mean gestational age of 34.4 weeks. Results Median aIMT was higher in fetuses with IUGR (0.504 mm [95%CI: 0.477-0.530 mm]), than in SGA fetuses (0.466 mm [95% CI: 0.447–0.485 mm]), and AGA fetuses (0.471 mm [95% CI: 0.454-0.488 mm]) (p = 0.023). Mean AD was significantly lower in fetuses with IUGR (4.451 mm [95% CI: 4.258–4.655 mm]), than in AGA fetuses (4.74 mm [95% CI: 4.63-4.843 mm]) (p = 0.028). Conclusions Growth restricted fetuses have a thicker aortic wall than AGA and SGA fetuses, which possibly represents preclinical atherosclerosis and a predisposition to later cardiovascular disease. PMID:26017141

  20. Biomechanical characteristics of C1-2 cable fixations.

    PubMed

    Dickman, C A; Crawford, N R; Paramore, C G

    1996-08-01

    The biomechanical characteristics of four different methods of C1-2 cable fixation were studied to assess the effectiveness of each technique in restoring atlantoaxial stability. Biomechanical testing was performed on the upper cervical spines of four human cadaveric specimens. Physiological range loading was applied to the atlantoaxial specimens and three-dimensional motion was analyzed with stereophotogrammetry. The load-deformation relationships and kinematics were measured, including the stiffness, the angular ranges of motion, the linear ranges of motion, and the axes of rotation. Specimens were nondestructively tested in the intact state, after surgical destabilization, and after each of four different methods of cable fixation. Cable fixation techniques included the interspinous technique, the Brooks technique, and two variants of the Gallie technique. All specimens were tested immediately after fixation and again after the specimen was fatigued with 6000 cycles of physiological range torsional loading. All four cable fixation methods were moderately flexible immediately; the different cable fixations allowed between 5 degrees and 40 degrees of rotational motion and between 0.6 and 7 mm of translational motion to occur at C1-2. The Brooks and interspinous methods controlled C1-2 motion significantly better than both of the Gallie techniques. The motion allowed by one of the Gallie techniques did not differ significantly from the motion of the unfixed destabilized specimens. All cable fixation techniques loosened after cyclic loading and demonstrated significant increases in C1-2 rotational and translational motions. The bone grafts shifted during cyclic loading, which reduced the effectiveness of the fixation. The locations of the axes of rotation, which were unconstrained and mobile in the destabilized specimens, became altered with cable fixation. The C1-2 cables constrained motion by shifting the axes of rotation so that C-1 rotated around the fixed cable

  1. Progression Rates of Carotid Intima-media Thickness and Adventitial Diameter during the Menopausal Transition

    PubMed Central

    El Khoudary, Samar R.; Wildman, Rachel P.; Matthews, Karen; Thurston, Rebecca C.; Bromberger, Joyce T.; Sutton-Tyrrell, Kim

    2012-01-01

    Objectives The authors assessed whether the levels and progression rates of carotid intima-media thickness (IMT) and adventitial diameter (AD) vary by menopausal stage. Methods 249 Women (42–57 years old, premenopausal (49%) or early peri-menopausal (46%)) from the Study of Women’s Health Across the Nation were included in the current analysis. Participants were followed for up to 9 years (median=3.7 years) and had up to 5 carotid scans. Linear mixed models were used for analysis. Results The overall rate of change in IMT was 0.007 mm/year. Independent of age and race, progression rate of IMT increased substantially in late peri-menopausal stage (0.017 mm/year) compared to both premenopausal (0.007 mm/year) and early peri-menopausal (0.005 mm/year) stages; (P≤0.05). For AD, while the overall rate of change was negative (−0.009 mm/year), significant positive increases in the rate of change were observed in late peri-menopausal (0.024 mm/year) and postmenopausal (0.018 mm/year) stages compared to premenopausal stage (−0.032 mm/year); (P<0.05). In final models, postmenopausal stage was independently associated with higher levels of IMT and AD (P<0.05) compared to premenopausal stage. Conclusions During the menopausal transition, the carotid artery undergoes an adaptation that is reflected in adverse changes in IMT and AD. These changes may impact the vulnerability of the vessel to disease in older women. PMID:22990755

  2. Evaluation of the Diode laser (810nm,980nm) on dentin tubule diameter following internal bleaching

    PubMed Central

    Kiomarsi, Nazanin; Salim, Soheil; Sarraf, Pegah; Javad-Kharazifard, Mohammad

    2016-01-01

    Background The aim of this study was to evaluate the effect of diode laser irradiation and bleaching materials on the dentinal tubule diameter after laser bleaching. Material and Methods The dentin discs of 40 extracted third molar were used in this experiment. Each disc surface was divided into two halves by grooving. Half of samples were laser bleached at different wavelengths with two different concentrations of hydrogen peroxide. Other half of each disc with no laser bleaching remained as a negative control. Dentin discs were assigned randomly into four groups (n=10) with following hydrogen peroxide and diode laser wavelength specifications; Group 1 (30% - 810 nm), group 2 (30% - 980 nm), group 3 (46% - 810 nm) and group 4 (46% - 980 nm). All specimens were sent for scanning electron microscopic (SEM) analysis in order to measure tubular diameter in laser treated and control halves. Data were analyzed by ANOVA and Tukey test (p<0.05). Results A significant reduction in dentin tubule diameter was observed in groups 1, 2 and 4. There was no significant difference between groups 1 and 2 and between groups 3 and 4 after bleaching. Conclusions The SEM results showed that diode laser was able to reduce dentin tubule diameter and its effect on dentin was dependent on chemical action of bleaching material. Key words:Laser, diode, dentin, tubule, diameter. PMID:27398172

  3. Relationship between Modelling Accuracy and Inflection Point Attributes of Several Equations while Modelling Stand Diameter Distributions.

    PubMed

    Duan, Aiguo; Zhang, Jianguo; Zhang, Xiongqing; He, Caiyun

    2015-01-01

    In this study, seven popular equations, including 3-parameter Weibull, 2-parameter Weibull, Gompertz, Logistic, Mitscherlich, Korf and R distribution, were used to model stand diameter distributions for exploring the relationship between the equations' inflection point attributes and model accuracy. A database comprised of 146 diameter frequency distributions of Chinese fir (Cunninghamia lanceolata (Lamb.) Hook.) plantations was used to demonstrate model fitting and comparison. Results showed that the inflection points of the stand diameter cumulative percentage distribution ranged from 0.4 to 0.6, showing a 1/2 close rule. The equation's inflection point attribute was strongly related to its model accuracy. Equation with an inflection point showed much higher accuracy than that without an inflection point. The larger the effective inflection point interval of the fitting curve of the equation was, and the closer the inflection point was to 0.5 for the equations with fixed inflection points, the higher the equation's accuracy was. It could be found that the equation's inflection point had close relationship with skewness of diameter distribution and stand age, stand density, which provided a scientific basis for model selection of a stand diameter distribution for Chinese fir plantations and other tree species. PMID:26016995

  4. Relationship between Modelling Accuracy and Inflection Point Attributes of Several Equations while Modelling Stand Diameter Distributions

    PubMed Central

    Duan, Aiguo; Zhang, Jianguo; Zhang, Xiongqing; He, Caiyun

    2015-01-01

    In this study, seven popular equations, including 3-parameter Weibull, 2-parameter Weibull, Gompertz, Logistic, Mitscherlich, Korf and R distribution, were used to model stand diameter distributions for exploring the relationship between the equations’ inflection point attributes and model accuracy. A database comprised of 146 diameter frequency distributions of Chinese fir (Cunninghamia lanceolata (Lamb.) Hook.) plantations was used to demonstrate model fitting and comparison. Results showed that the inflection points of the stand diameter cumulative percentage distribution ranged from 0.4 to 0.6, showing a 1/2 close rule. The equation’s inflection point attribute was strongly related to its model accuracy. Equation with an inflection point showed much higher accuracy than that without an inflection point. The larger the effective inflection point interval of the fitting curve of the equation was, and the closer the inflection point was to 0.5 for the equations with fixed inflection points, the higher the equation’s accuracy was. It could be found that the equation’s inflection point had close relationship with skewness of diameter distribution and stand age, stand density, which provided a scientific basis for model selection of a stand diameter distribution for Chinese fir plantations and other tree species. PMID:26016995

  5. A Cadaveric Study of the Branching Pattern and Diameter of the Genicular Arteries: A Focus on the Middle Genicular Artery.

    PubMed

    Shahid, Shahab; Saghir, Noman; Cawley, Oliver; Saujani, Shyamal

    2015-10-01

    The aim of the study was to gain an appreciation of the variation in the branching pattern and diameter of the genicular arteries arising directly from the popliteal artery (PA), namely, the superior medial genicular artery (SMGA), superior lateral genicular artery (SLGA), inferior medial genicular artery (IMGA), inferior lateral genicular artery (ILGA), and middle genicular artery (MGA). Twenty cadaveric knees aged between 62 and 92 years were dissected. A posterior midline vertical incision was used to gain access to the PA. The diameter of the PA, the sequence of branching, and subsequent diameter of genicular vessels and common trunks were recorded. PA average diameter was 7.9 mm. The SMGA (1.6-mm diameter) was the first branch in 45% and the second branch in 20%, and in seven limbs it arose from a common trunk with the SLGA. The SLGA was the second branch in 30% and the first branch in 25%, and it branched from a common trunk in 45%. The MGA (1.1-mm diameter) arose as the second branch in four knees and as the third branch in eight knees. It arose from a common trunk in eight knees, either with a superior genicular (three knees) or with an inferior genicular (five knees). The IMGA (1.5-mm diameter) was the third branch in 25%, the fourth branch in 35%, and the fifth branch in 15%. In five cases, it arose from a common trunk (25%). The ILGA (1.4-mm diameter) was the third branch in 15%, the fourth branch in 30%, and the fifth branch in 25%. It arose from a common trunk in six knees. These trunks also gave rise to the IMGA in all cases. There is extensive variation in the branching pattern and diameter of the genicular arteries differing from textbook descriptions. An awareness of vascular variation is imperative for preservation of the blood supply to the knee, which may promote recovery after anterior cruciate ligament reconstruction and popliteal aneurysm repair. PMID:25892007

  6. Structural properties of free-standing 50 mm diameter GaN waferswith (101_0) orientation grown on LiAlO2

    SciTech Connect

    Jasinski, Jacek; Liliental-Weber, Zuzanna; Maruska, Herbert-Paul; Chai, Bruce H.; Hill, David W.; Chou, Mitch M.C.; Gallagher, John J.; Brown, Stephen

    2005-09-27

    (10{und 1}0) GaN wafers grown on (100) face of {gamma}-LiAlO{sub 2} were studied using transmission electron microscopy. Despite good lattice matching in this heteroepitaxial system, high densities of planar structural defects in the form of stacking faults on the basal plane and networks of boundaries located on prism planes inclined to the layer/substrate interface were present in these GaN layers. In addition, significant numbers of threading dislocations were observed. High-resolution electron microscopy indicates that stacking faults present on the basal plane in these layers are of low-energy intrinsic I1type. This is consistent with diffraction contrast experiments.

  7. Inherent capacity of the pituitary gland to produce gonadotropins is not influenced by the number of ovarian follicles > or = 3 mm in diameter in cattle.

    PubMed

    Mossa, F; Jimenez-Krassel, F; Walsh, S; Berry, D P; Butler, S T; Folger, J; Smith, G W; Ireland, J L H; Lonergan, P; Ireland, J J; Evans, A C O

    2010-01-01

    We hypothesised that higher serum FSH concentrations in cattle with low v. high follicle numbers during follicular waves are caused by a different capacity of the pituitary gland to produce gonadotropins. Dairy cows with high (> or = 30; n = 5) and low (< or = 15; n = 5) follicle numbers were selected and serum concentrations of oestradiol and FSH during an oestrous cycle were measured. Cows were ovariectomised at oestrus and bled frequently up to 8 days after ovariectomy. After 33 days, cows were injected with gonadotropin-releasing hormone (GnRH) and bled intensively up to 8 h after GnRH injection. One day later, animals were injected with follicular fluid (FF) from bovine follicles and were bled intensively up to 2 days after the first injection. Serum concentrations of FSH and LH were measured. After 2 days, cows were killed and their pituitary glands collected. Prior to ovariectomy, serum oestradiol concentrations were similar between groups, whereas FSH concentrations were higher in cattle with low v. high numbers of follicles. No differences were detected in serum gonadotropin concentrations after ovariectomy, GnRH injection or FF challenge between groups. The results indicate that the inherent capacity of the pituitary gland to secrete gonadotropins does not differ between cattle with high v. low numbers of follicles during follicular waves. PMID:20188028

  8. Fiber diameter distributions in the chinchilla's ampullary nerves

    NASA Technical Reports Server (NTRS)

    Hoffman, Larry F.; Honrubia, Vicente

    2002-01-01

    A morphometric study of the chinchilla's ampullary nerves was conducted to produce an unbiased accounting of the diameter distribution of their constituent fibers. Diameter analyses were determined from 1 microm plastic-embedded nerve sections taken at a plane immediately proximal to the sensory epithelium. We found these nerves to be composed of 2094+/-573 fibers, having diameters that ranged from 0.5 to 8 microm. The distributions of diameters were positively skewed, where approximately 75% of the fibers were found to have diameters less than 3.5 microm. An analysis of the spatial distribution of diameters within the nerve section revealed that the lateralmost areas of the nerve contained larger fractions of fibers within the smallest diameter quintiles, and the central area harbored greater proportions of the larger diameter quintiles. However, significant fractions of all quintiles were found in all areas. These data were integrated with available data of Fernandez et al. (1998) to produce diameter estimates of calyx, dimorphic, and bouton morphology subpopulations. In view of a general relationship between diameter, innervation locus, and an afferent's physiologic characteristics, these data provide the basis for developing a perspective for the in situ distribution of afferent response dynamics.

  9. Spray impact on a smooth, unheated surface: drop impact cavity diameter vs time

    NASA Astrophysics Data System (ADS)

    Kuhlman, John; Taylor, Jonathan; Hillen, Nicholas; Sommers, Christopher; WVU Spray Cooling Laboratory Team

    2014-11-01

    A dense water spray impacting a smooth, unheated glass surface is studied. Average drop diameter is 90--60 microns; average axial velocity is 7.5--12 m/s for nozzle pressures of 1.4--4.2 bar gage, respectively, from PDPA data. Average spray Weber numbers are 70--130. Half the spray mass flux is due to larger drops with Weber numbers of 200--800, causing the splashed secondary drops and large impact cavities with longer lifetimes. Liquid film thickness is about 160 microns at all radii over the present range of nozzle pressures, with transient fluctuations of 30--40 microns. This thickness increases vs drop radial impact location, and decreases vs nozzle pressure. Drop impact cavity diameter from video images is 0.5 mm--1.5 mm, giving drop diameters of 100--300 microns, consistent with the PDPA data. Spray drop impact cavity growth vs time is fit approximately by (t) 0 . 2 as seen in the literature. These results will be used to improve correlations in an existing preliminary Monte Carlo model of the complex spray impact process. It is believed that the transient thin liquid films formed beneath the droplet impact cavities are an important source of heat transfer augmentation via transient conduction. Supported under NASA Cooperative Agreement NNX10AN0YA.

  10. Improving predictions of root biomechanical properties, is age a better determinant than diameter?

    NASA Astrophysics Data System (ADS)

    Loades, Kenneth; Hallett, Paul; Lynch, Jonathan; Chimungu, Joseph; Bengough, Anthony

    2014-05-01

    Roots mechanically reinforce many soils. Root tensile strength and stiffness is critical for soil stabilisation with plants potentially providing civil engineers a 'green' alternative for soil stabilisation. Relatively little is known on factors influencing root tensile strength. Through a better understanding of these factors the adoption of 'green engineering' techniques by civil engineers will improve. Existing models are limited in their accuracy due to simplistic assumptions to derive root contributions to the resistance of soil to failure. Current models typically use relationships between strength and diameter, however, there are a number of other factors potentially influencing root biomechanical properties. The effects of root age on biomechanical properties have largely been overlooked. Barley (Hordeum vulgare) was grown under differing soil conditions, waterlogged, moderate mechanical impedance and in unimpeded, control, conditions. The root system was excavated and tensile tests performed on root sections along the length of each root axis. Root tensile strength increased with increasing distance along the root axes in control soil from 0.5 MPa to 7.0 MPa at a distance of 800mm from the root tip and from 1.0 Mpa to 8.0 MPa, 500mm from the root tip when under moderate mechanical impedance. Increases in strength were also observed when plants were subjected to waterlogging with tensile strength increasing from 1.0 MPa to 3.0 MPa, 200mm from the root tip. Young's modulus increased from ~10 MPa at the root tip to ~60 MPa 400mm and 800mm from the root tip in mechanically impeded and control treatments respectively. Distance from root tip explained over 47% of the variance in root tensile strength and 34% of root stiffness. Including root diameter in the model led to further improvements in predicting root properties, explaining ~54% of root strength variance and ~49% of root stiffness. Root age has been shown to improve predictions of root tensile strength

  11. Is smaller better? Comparison of 3-mm and 5-mm leaf size for stereotactic radiosurgery: A dosimetric study

    SciTech Connect

    Chern, Shyh-shi . E-mail: Richard.Chern@hci.utah.edu; Leavitt, Dennis D.; Jensen, Randy L.; Shrieve, Dennis C.

    2006-11-15

    Purpose: To perform a dosimetric comparison of a minimal 3-mm leaf width multileaf collimator (MLC) and a minimal 5-mm MLC in dynamic conformal arc stereotactic radiosurgery for treatment of intracranial lesions. Methods and Materials: The treatment plans of 23 patients previously treated for intracranial lesions in our institution were redone using the BrainSCAN, version 5.3, stereotactic radiosurgery treatment planning system (BrainLAB). For each case, two dynamic conformal arc plans were generated: one using a minimal 3-mm micro-MLC (BrainLAB, Novalis) and one using a minimal 5-mm MLC (Varian Millennium). All arc parameters were the same in each of the two plans, except for the collimator angle settings. The collimator angle settings were optimized for each arc in each plan. A peritumoral rind structure (1 cm) was created to evaluate normal tissue sparing immediately adjacent to the target volume. Conformity indexes (CIs) were calculated for each plan. The dependence of normal tissue sparing and target conformity on target volume (TV) was determined. Results: The TV was 0.14-36.32 cm{sup 3} (median, 5.90). The CI was 1.22-2.60 (median, 1.51) for the 3-mm micro-MLC and 1.23-2.69 (median, 1.60) for the 5-mm MLC. Despite this small difference, it was a statistically significant increase (p < 0.0001) for the 5-mm MLC compared with the 3-mm micro-MLC. Improved normal tissue sparing was demonstrated using the 3-mm micro-MLC compared with the 5-mm MLC by examining the peritumoral rind volumes (PRVs) receiving 50% (PRV{sub 5}), 80% (PRV{sub 8}), and 90% (PRV{sub 9}) of the prescription dose. The reduction in the PRV{sub 5}, PRV{sub 8}, and PRV{sub 9} for the 3-mm micro-MLC compared with the 5-mm MLC was 13.5%, 12.9%, and 11.5%, respectively. The CI decreased with a larger TV, as did the difference in the CIs between the 3-mm micro-MLC and 5-mm MLC. A reduction in the PRV increased with larger TVs. Conclusion: The 3-mm micro-MLC provided better target conformity and

  12. Hybrid X Pinches at 1.2 MA

    NASA Astrophysics Data System (ADS)

    Shelkovenko, Tatiana A.; Pikuz, Sergey A.; Cahill, Adam D.; Hoyt, Cad L.; Hammer, David A.; Tilikin, Ivan N.; Mishin, Sergey N.; Mingaleev, Albert R.

    2012-10-01

    A hybrid X-pinch (HXP) configuration consisting of solid conical electrodes connected by a wire as a central load has been tested on four different generators with currents varying from 200 kA to 1.2 MA and risetimes ranging from 50 ns to 170 ns. It was possible to optimize the wire material, length and diameter so that most of these HXPs generated an intense single burst of soft x-rays with energy yield comparable with that produced by standard X pinches. This configuration is useful primarily for pulsers with MA current level and was suggested to simplify standard wire X-pinch configurations with many wires. Wires as well as hollow and filled tubes made of Al, Ni and polyethylene were tested as a load on the COBRA pulser (1.2 MA, 100 ns rise time). The filled tubes expand the range of materials that can be studied under extreme conditions. Electron beams generation in HXPs has also been studied.

  13. Index to 8mm Motion Cartridges. Third Edition.

    ERIC Educational Resources Information Center

    University of Southern California, Los Angeles. National Information Center for Educational Media.

    Research at the National Information Center for Educational Media has shown that the 8mm motion cartridge with optical and magnetic sound seems to meet the basic tenets of a prime educational criterion for an educational medium--that it be available to the learner at his convenience. This is a bibliographical source for 8mm motion cartridges, and…

  14. Index to 8mm Motion Cartridges. Fourth Edition.

    ERIC Educational Resources Information Center

    University of Southern California, Los Angeles. National Information Center for Educational Media.

    Research at the National Information Center for Educational Media (NICEM) has shown that the 8mm motion cartridge with optical and magnetic sound seems to meet the basic tenets of a prime educational criterion for an educational medium--that it be available to the learner at his convenience. This is a bibliographical source for 8mm motion…

  15. Do Noncontingent Interviewer Mm-hmms Facilitate Interviewee Productivity?

    ERIC Educational Resources Information Center

    Siegman, Aron Wolfe

    1976-01-01

    Two studies investigated the hypothesis that noncontingent interviewer "mm-hmms" facilitate interviewee verbal productivity. Within- and between-subjects comparisons failed to support the hypothesis, although interviewees' ratings indicate that the mm-hmms were perceived as the social reinforcers they were intended to be. (Author)

  16. Saqqar: A 34 km diameter impact structure in Saudi Arabia

    NASA Astrophysics Data System (ADS)

    Kenkmann, Thomas; Afifi, Abdulkader M.; Stewart, Simon A.; Poelchau, Michael H.; Cook, Douglas J.; Neville, Allen S.

    2015-11-01

    Here we present the first proof of an impact origin for the Saqqar circular structure in northwestern Saudi Arabia (Neville et al. ), with an apparent diameter of 34 km, centered at 29°35'N, 38°42'E. The structure is formed in Cambrian-Devonian siliciclastics and is unconformably overlain by undeformed Cretaceous and Paleogene sediments. The age of impact is not well constrained and lies somewhere between 410 and 70 Ma. The subsurface structure is constrained by 2-D reflection seismic profiles and six drilled wells. First-order structural features are a central uplift that rises approximately 2 km above regional datums, surrounded by a ring syncline. The crater rim is defined by circumferential normal faults. The central uplift and ring syncline correspond to a Bouguer gravity high and an annular ring-like low, respectively. The wells were drilled within the central uplift, the deepest among them exceed 2 km depth. Sandstone core samples from these wells show abundant indicators of a shock metamorphic overprint. Planar deformation features (PDFs) were measured with orientations along (0001), {101¯3}, and less frequently along {101¯1} and {101¯4}. Planar fractures (PFs) predominantly occur along (0001) and {101¯1}, and are locally associated with feather features (FFs). In addition, some shocked feldspar grains and strongly deformed mica flakes were found. The recorded shock pressure ranges between 5 and 15 GPa. The preserved level of shock and the absence of an allochthonous crater fill suggest that Saqqar was eroded by 1-2 km between the Devonian and Maastrichtian. The documentation of unequivocal shock features proves the formation of the Saqqar structure by a hypervelocity impact event.

  17. Thales Angenieux: 42 years of cine 35 mm zoom leadership

    NASA Astrophysics Data System (ADS)

    Debize, Jacques

    2004-02-01

    Since the early years of zoom optics, Angenieux has been involved in cine 8 mm, 16 mm and 35 mm. Among more than twenty different zoom lenses, four of them have been milestones in this field, technical progresses being sanctified by two Oscars in 1964 and 1990. From 1960 to 2002 Angenieux has created first the 4 x 35 LA2, the first four times mechanically compensated zoom lens for cine 35 mm in the world, secondary the 10 x 25 T2, the first ten times mechanically compensated zoom lens for cine 35 mm in the world, then the 10 x 25 HR, the top level of quality for its category and finally the 12 x 24 Optimo with all characteristics and performances greatly increased. This leadership has been reached thanks to computers and in-house softwares but also thanks to new manufacturing processes.

  18. In vitro evaluation of Root ZX and Raypex 6 in teeth with different apical diameters

    PubMed Central

    Aydin, Ugur; Karataslioglu, Emrah; Aksoy, Fatih; Yildirim, Cihan

    2015-01-01

    Background: There is a growing interest about electronic apex locators for working length determination. There are several studies dealing with their performance in different conditions. Aims: The aim of this study is to evaluate the accuracy of Root ZX and Raypex 6 in teeth with different apical diameters. Materials and Methods: Actual working length (AWL) of 80 single rooted teeth were determined as 0.5 mm short of apical foramen. The teeth were divided into 4 groups (n = 20). First group (G 0) included teeth with mature apices. Root canals of the other groups (G 32, G 57 and G 72) were enlarged until apical sizes of 0.32, 0.57 and 0.72 mm were obtained. Samples were embedded in alginate and electronic measurements (EM) were performed. Statistical analysis: was achieved with Fisher exact test. Results: Both devices revealed a high rate of success in G 0 and G 32. Their accuracy decreased significantly in G 57 and G 72 groups (P < 0.05). Intra-group results of Root ZX and Raypex 6 were similar (P > 0.05). Conclusions: Root ZX and Raypex 6 are reliable in teeth with mature apices. At foramen diameters exceeding 0.57 mm, their accuracy is susceptible. PMID:25657531

  19. 1,2-Dibromo-3-chloropropane (DBCP)

    Integrated Risk Information System (IRIS)

    1,2 - Dibromo - 3 - chloropropane ( DBCP ) ; CASRN 96 - 12 - 8 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessm

  20. 1,1,2,2-Tetrachloroethane

    Integrated Risk Information System (IRIS)

    1,1,2,2 - Tetrachloroethane ; CASRN 79 - 34 - 5 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncar

  1. 1,2,4,5-Tetrachlorobenzene

    Integrated Risk Information System (IRIS)

    1,2,4,5 - Tetrachlorobenzene ; CASRN 95 - 94 - 3 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Nonca

  2. 1,1,1,2-Tetrachloroethane

    Integrated Risk Information System (IRIS)

    1,1,1,2 - Tetrachloroethane ; CASRN 630 - 20 - 6 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Nonca

  3. 1,1,1,2-Tetrafluoroethane

    Integrated Risk Information System (IRIS)

    1,1,1,2 - Tetrafluoroethane ; CASRN 811 - 97 - 2 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Nonca

  4. 1,2,3-triazolium ionic liquids

    SciTech Connect

    Luebke, David; Nulwala, Hunaid; Tang, Chau

    2014-12-09

    The present invention relates to compositions of matter that are ionic liquids, the compositions comprising substituted 1,2,3-triazolium cations combined with any anion. Compositions of the invention should be useful in the separation of gases and, perhaps, as catalysts for many reactions.

  5. 3D Imaging with a Single-Aperture 3-mm Objective Lens: Concept, Fabrication and Test

    NASA Technical Reports Server (NTRS)

    Korniski, Ron; Bae, Sam Y.; Shearn, Mike; Manohara, Harish; Shahinian, Hrayr

    2011-01-01

    There are many advantages to minimally invasive surgery (MIS). An endoscope is the optical system of choice by the surgeon for MIS. The smaller the incision or opening made to perform the surgery, the smaller the optical system needed. For minimally invasive neurological and skull base surgeries the openings are typically 10-mm in diameter (dime sized) or less. The largest outside diameter (OD) endoscope used is 4mm. A significant drawback to endoscopic MIS is that it only provides a monocular view of the surgical site thereby lacking depth information for the surgeon. A stereo view would provide the surgeon instantaneous depth information of the surroundings within the field of view, a significant advantage especially during brain surgery. Providing 3D imaging in an endoscopic objective lens system presents significant challenges because of the tight packaging constraints. This paper presents a promising new technique for endoscopic 3D imaging that uses a single lens system with complementary multi-bandpass filters (CMBFs), and describes the proof-of-concept demonstrations performed to date validating the technique. These demonstrations of the technique have utilized many commercial off-the-shelf (COTS) components including the ones used in the endoscope objective.

  6. Lunar Brightness Variations with Phase at 4.3-MM Wave Length

    NASA Technical Reports Server (NTRS)

    Coates, Robert J.

    1961-01-01

    The lunar radio observations and interpretations of Piddington and Minnett (1949) and Gibson (1958) show that the lunar brightness variation with phase at millimeter wave lengths can be used to determine the physical properties of the lunar surface. They found that the millimeter-wave brightness lagged the optical phase, and their interpretation was that the millimeter radiation originates below a surface layer that is a very good thermal insulator. The thickness of this layer could not be determined from observations at one frequency. Observations at different frequencies give different results because of the wave-length dependence of the radio absorption by the surface material. The attenuation in the material increases with decreasing wave length, and therefore it is possible, in principle, to determine surface layer thickness from radio observations at several wave lengths. For this reason, observations of lunar radiation were started at the Naval Research Laboratory at a wave length of 4.3 mm. This is half the wave length used by Gibson (1958) in his earlier studies. The radio telescope used for these observations has been described in detail in a previous publication (Coates 1958). The antenna is a parabolic reflector 10 feet in diameter, and it has a beam width of 6.7 minutes of arc at the wave length of 4.3 mm. This is about one-fifth the diameter of the moon. The receiver was a Dicke-type radiometer.

  7. The relationship between inferior vena cava diameter measured by bedside ultrasonography and central venous pressure value

    PubMed Central

    Citilcioglu, Serenat; Sebe, Ahmet; Oguzhan Ay, Mehmet; Icme, Ferhat; Avci, Akkan; Gulen, Muge; Sahan, Mustafa; Satar, Salim

    2014-01-01

    Objective: We aimed to present inferior vena cava (IVC) diameter as a guiding method for detection of relationship between IVC diameter measured noninvasively with the help of ultrasonography (USG) and central venous pressure (CVP) and evaluation of patient's intravascular volume status. Methods: Patients over the age of 18, to whom a central venous catheter was inserted to their subclavian vein or internal jugular vein were included in our study. IVC diameter measurements were recorded in millimeters following measurement by the same clinician with the help of USG both at the end-inspiratory and end-expiratory phase. CVP measurements were viewed on the monitor by means of piezoelectric transducer and recorded in mmHg. SPSS 18.0 package program was used for statistical analysis of data. Results: Forty five patients were included in the study. The patients had the diagnosis of malignancy (35.6%), sepsis (13.3%), pneumonia, asthma, chronic obstructive pulmonary disease (11.1%). 11 patients (24.4%) required mechanical ventilation while 34 (75.6%) patients had spontaneous respiration. In patients with spontaneous respiration, a significant relationship was found between IVC diameters measured by ultrasonography at the end of expiratory and inspiratory phases and measured CVP values at the same phases (for expiratory p = 0.002, for inspiratory p= 0.001). There was no statistically significant association between IVC diameters measured by ultrasonography at the end of expiration and inspiration and measured CVP values at the same phases in mechanically ventilated patients. Conclusions: IVC diameter measured by bedside ultrasonography can be used for determination of the intravascular volume status of the patients with spontaneous respiration. PMID:24772133

  8. Hyaluronic acid enhancement of expanded polytetrafluoroethylene for small diameter vascular grafts

    NASA Astrophysics Data System (ADS)

    Lewis, Nicole R.

    Cardiovascular disease is the leading cause of mortality and morbidity in the United States and other developed countries. In the United States alone, 8 million people are diagnosed with peripheral arterial disease per year and over 250,000 patients have coronary bypass surgery each year. Autologous blood vessels are the standard graft used in small diameter (<6mm) arterial bypass procedures. Synthetic small diameter grafts have had limited success. While polyethylene (Dacron) and expanded polytetrafluoroethylene (ePTFE) are the most commonly used small diameter synthetic vascular graft materials, there are significant limitations that make these materials unfavorable for use in the low blood flow conditions of the small diameter arteries. Specifically, Dacron and ePTFE grafts display failure due to early thrombosis or late intimal hyperplasia. With the shortage of tissue donors and the limited supply of autologous blood vessels available, there is a need for a small diameter synthetic vascular graft alternative. The aim of this research is to create and characterize ePTFE grafts prepared with hyaluronic acid (HA), evaluate thrombogenic potential of ePTFE-HA grafts, and evaluate graft mechanical properties and coating durability. The results in this work indicate the successful production of ePTFE-HA materials using a solvent infiltration technique. Surface interactions with blood show increased platelet adhesion on HA-modified surfaces, though evidence may suggest less platelet activation and erythrocyte lysis. Significant changes in mechanical properties of HA-modified ePTFE materials were observed. Further investigation into solvent selection, uniformity of HA, endothelialization, and dynamic flow testing would be beneficial in the evaluation of these materials for use in small diameter vascular graft bypass procedures.

  9. Diameter Controlled of Carbon Nanotubes Synthesized on Nanoporous Silicon Support

    NASA Astrophysics Data System (ADS)

    Asli, N. A.; Shamsudin, M. S.; Maryam, M.; Yusop, S. F. M.; Suriani, A. B.; Rusop, M.; Abdullah, S.

    2013-06-01

    Carbon nanotubes (CNTs) have been successfully synthesized on nanoporous silicon template (NPSiT) using botanical source, camphor oil. Diameter of CNTs synthesized was controlled by pore size of NPSiT prepared by photo-electrochemical anodization method. The diameter of CNTs grown on different NPSiT corresponded to the pore diameter of NPSiT. FESEM images showed self-organized bundles of fiber-like structures of CNTs with diameter of around 20nm which were successfully grown directly on nanoporous silicon while raman spectra obtained ratio of ID/IG at 0.67.

  10. Wire diameter dependence in the catalytic decomposition of H2

    NASA Astrophysics Data System (ADS)

    Umemoto, Hironobu

    2014-01-01

    Jansen et al. have demonstrated that the dissociaiton rate of H2 molecules on hot wire surfaces, normalized per unit surface area, depends on the wire diameter based on the electrical power consumption measurements [J. Appl. Phys. 66, 5749 (1989)]. Mathematical modeling calculations have also been presented to support their experimental results. In the present paper, it is shown that such a wire diameter dependence cannot be observed and that the H-atom density normalized by the wire surface area depends little on the wire diameter. Modeling calculations also show that the wire diameter dependence of the dissociation rate cannot be expected under typical decomposition conditions.

  11. Effect of Specimen Diameter on Tensile Properties of Austenitic Stainless Steels in Liquid Hydrogen and Gaseous Helium at 20K

    NASA Astrophysics Data System (ADS)

    Fujii, H.; Ohmiya, S.; Shibata, K.; Ogata, T.

    2006-03-01

    Tensile tests using round bar type specimens of 3, 5 and 7 mm in diameter were conducted at 20K in liquid hydrogen and also in gaseous helium at the same temperature for three major austenitic stainless steels, JIS SUS304L, 316L and 316LN, extensively used for cryogenic applications including liquid hydrogen transportation and storage vessels. Stress-strain curves were considerably different between circumstances and also specimen diameter, resulting in differences of strength and ductility. In liquid hydrogen, serrated deformation appeared after considerable work hardening and more active in specimens with larger diameter. Meanwhile serrated deformation was observed from the early stage of plastic deformation in gaseous helium at 20 K and serration was more frequent in specimens with smaller diameter. The serrated deformation behaviors were numerically simulated for 304L steel with taking thermal properties such as thermal conductivity, specific heat, heat transfer from specimens to cryogenic media into account, and some agreement with the experiments was obtained.

  12. Effect of Specimen Diameter on Tensile Properties of Austenitic Stainless Steels in Liquid Hydrogen and Gaseous Helium at 20K

    SciTech Connect

    Fujii, H.; Ohmiya, S.; Shibata, K.; Ogata, T.

    2006-03-31

    Tensile tests using round bar type specimens of 3, 5 and 7 mm in diameter were conducted at 20K in liquid hydrogen and also in gaseous helium at the same temperature for three major austenitic stainless steels, JIS SUS304L, 316L and 316LN, extensively used for cryogenic applications including liquid hydrogen transportation and storage vessels. Stress-strain curves were considerably different between circumstances and also specimen diameter, resulting in differences of strength and ductility. In liquid hydrogen, serrated deformation appeared after considerable work hardening and more active in specimens with larger diameter. Meanwhile serrated deformation was observed from the early stage of plastic deformation in gaseous helium at 20 K and serration was more frequent in specimens with smaller diameter. The serrated deformation behaviors were numerically simulated for 304L steel with taking thermal properties such as thermal conductivity, specific heat, heat transfer from specimens to cryogenic media into account, and some agreement with the experiments was obtained.

  13. Internal rotation for predicting conformational population of 1,2-difluorethane and 1,2-dichloroethane

    NASA Astrophysics Data System (ADS)

    Venâncio, Mateus F.; Dos Santos, Hélio F.; De Almeida, Wagner B.

    2016-06-01

    The contribution of internal rotation to the thermal correction of Gibbs free energy (ΔG) is estimated using the quantum pendulum model (QPM) to solve the characteristic Schrödinger equation. The procedure is applied to theoretical prediction of conformational population of 1,2-difluorethane (1,2-DFE) and 1,2-dichloroethane (1,2-DCE) molecules. The predicted population for the anti form was 37% and 75%, for 1,2-DFE and 1,2-DCE respectively, in excellent agreement with experimental gas phase data available, 37 ± 5% and 78 ± 5%. These results provide great support to the use of the QPM model to account for the low vibrational frequency modes effect on the calculation of thermodynamic properties.

  14. Amplitude modulation drive to rectangular-plate linear ultrasonic motors with vibrators dimensions 8 mm x 2.16 mm X 1 mm.

    PubMed

    Ming, Yang; Hanson, Ben; Levesley, Martin C; Walker, Peter G; Watterson, Kevin G

    2006-12-01

    In this paper, to exploit the contribution from not only the stators but also from other parts of miniature ultrasonic motors, an amplitude modulation drive is proposed to drive a miniature linear ultrasonic motor consisting of two rectangular piezoelectric ceramic plates. Using finite-element software, the first longitudinal and second lateral-bending frequencies of the vibrator are shown to be very close when its dimensions are 8 mm x 2.16 mm x 1 mm. So one single frequency power should be able to drive the motor. However, in practice the motor is found to be hard to move with a single frequency power because of its small vibration amplitudes and big frequency difference between its longitudinal and bending resonance, which is induced by the boundary condition variation. To drive the motor effectively, an amplitude modulation drive is used by superimposing two signals with nearly the same frequencies, around the resonant frequency of the vibrators of the linear motor. When the amplitude modulation frequency is close to the resonant frequency of the vibrator's surroundings, experimental results show that the linear motor can move back and forward with a maximum thrust force (over 0.016 N) and a maximum velocity (over 50 mm/s). PMID:17186925

  15. Japanese Science Films; a Descriptive and Evaluative Catalog of: 16mm Motion Pictures, 8mm Cartridges, and Video Tapes.

    ERIC Educational Resources Information Center

    Newren, Edward F., Ed.

    One hundred and eighty Japanese 16mm motion pictures, 8mm cartridges, and video tapes produced and judged appropriate for a variety of audience levels are listed in alphabetical order by title with descriptive and evaluative information. A subject heading list and a subject index to the film titles are included, as well as a sample of the…

  16. Influence of hole diameter on the average size and quantity distribution of Si nanoparticles

    NASA Astrophysics Data System (ADS)

    Chu, Lizhi; Zong, Yu; Deng, Zechao; Ding, Xuecheng; Zhao, Hongdong; Wang, Yinglong

    2013-12-01

    The single crystalline Si target with high resistivity was ablated by a XeCl excimer laser (wavelength 308nm) in pure Ar gas under the ambient pressure of 10 Pa. The mask with a 1-10 mm diameter hole in the center was placed at a distance of 1.5 cm to the Si target. The Si nanocrystalline films were systemically deposited on a glass or single crystalline Si substrate placed behind the mask parallelly with a distance of 1.0 cm. The Raman and X-ray diffraction spectra indicate that the films were nanocrystalline. Scanning electron microscope images of the films showed that the diameter of the hole affected on the quantity and distributed range of Si nanoparticles on the substrate. It was obtained that the average size of Si nanoparticles decreasing with the diameter of the hole increasing, the quantity of Si nanoparticles was proportional to the power of 1.5 of the hole diameter. It is the nonlinear dynamic process to lead to the experimental result.

  17. Strouhal numbers, forces and flow structures around two tandem cylinders of different diameters

    NASA Astrophysics Data System (ADS)

    Mahbub Alam, Md.; Zhou, Y.

    2008-05-01

    This paper presents a detailed investigation of Strouhal numbers, forces and flow structures in the wake of two tandem cylinders of different diameters. While the downstream cylinder diameter, D, was fixed at 25 mm, the upstream cylinder diameter, d, was varied from 0.24D to D. The spacing between the cylinders was 5.5d, at which vortices were shed from both cylinders. Two distinct vortex frequencies were detected behind the downstream cylinder for the first time for two tandem cylinders of the same diameter. The two vortex frequencies remained for d/D=1.0 0.4. One was the same as detected in the gap of the cylinders, and the other was of relatively low frequency and was ascribed to vortex shedding from the downstream cylinder. While the former, if normalized, declined progressively from 0.196 to 0.173, the latter increased from 0.12 to 0.203 with decreasing d/D from 1 to 0.24. The flow structure around the two cylinders is examined in the context of the observed Strouhal numbers. The time-averaged drag on the downstream cylinder also climbed with decreasing d/D, though the fluctuating forces dropped because vortices impinging upon the downstream cylinder decreased in scale with decreasing d/D.

  18. Kinetics of 1,2-Dichloroethane and 1,2-Dibromoethane Biodegradation in Anaerobic Enrichment Cultures

    PubMed Central

    Yu, Rong; Peethambaram, Hari S.; Falta, Ronald W.; Verce, Matthew F.; Henderson, James K.; Bagwell, Christopher E.; Brigmon, Robin L.

    2013-01-01

    1,2-Dichloroethane (1,2-DCA) and 1,2-dibromoethane (ethylene dibromide [EDB]) contaminate groundwater at many hazardous waste sites. The objectives of this study were to measure yields, maximum specific growth rates (μ̂), and half-saturation coefficients (KS) in enrichment cultures that use 1,2-DCA and EDB as terminal electron acceptors and lactate as the electron donor and to evaluate if the presence of EDB has an effect on the kinetics of 1,2-DCA dehalogenation and vice versa. Biodegradation was evaluated at the high concentrations found at some industrial sites (>10 mg/liter) and at lower concentrations found at former leaded-gasoline sites (1.9 to 3.7 mg/liter). At higher concentrations, the Dehalococcoides yield was 1 order of magnitude higher when bacteria were grown with 1,2-DCA than when they were grown with EDB, while μ̂'s were similar for the two compounds, ranging from 0.19 to 0.52 day−1 with 1,2-DCA to 0.28 to 0.36 day−1 for EDB. KS was larger for 1,2-DCA (15 to 25 mg/liter) than for EDB (1.8 to 3.7 mg/liter). In treatments that received both compounds, EDB was always consumed first and adversely impacted the kinetics of 1,2-DCA utilization. Furthermore, 1,2-DCA dechlorination was interrupted by the addition of EDB at a concentration 100 times lower than that of the remaining 1,2-DCA; use of 1,2-DCA did not resume until the EDB level decreased close to its maximum contaminant level (MCL). In lower-concentration experiments, the preferential consumption of EDB over 1,2-DCA was confirmed; both compounds were eventually dehalogenated to their respective MCLs (5 μg/liter for 1,2-DCA, 0.05 μg/liter for EDB). The enrichment culture grown with 1,2-DCA has the advantage of a more rapid transition to 1,2-DCA after EDB is consumed. PMID:23263950

  19. A system for magnetostrictive transduction of guided waves in fluid-filled pipes of small diameter.

    PubMed

    Challis, Richard E; Phang, Albert P Y; Lowe, Michael J S; Mather, Melissa L

    2008-09-01

    This paper is concerned with the design of magnetostrictive transducers for the excitation and detection of guided waves in metal pipes of small diameter (mm) and their application to the study of wave propagation in pipes filled with water or supercritical CO(2). Optimized system design is based on a simulation of the overall signal pathway which includes the electric circuit conditions at the transducers, mode excitability, and the wavenumber filtering effect of the spatial distribution of the exciting alternating magnetic field. A prototype system was built, and experimental observations on small diameter pipes indicated good agreement with expected results from simulations. The reassigned spectrogram has been used to compare expectation on the basis of guided wave dispersion curves for fluid-filled pipes with experimental data. PMID:18986895

  20. Brain Arterial Diameters as a Risk Factor for Vascular Events

    PubMed Central

    Gutierrez, Jose; Cheung, Ken; Bagci, Ahmet; Rundek, Tatjana; Alperin, Noam; Sacco, Ralph L; Wright, Clinton B; Elkind, Mitchell S V

    2015-01-01

    Background Arterial luminal diameters are routinely used to assess for vascular disease. Although small diameters are typically considered pathological, arterial dilatation has also been associated with disease. We hypothesize that extreme arterial diameters are biomarkers of the risk of vascular events. Methods and Results Participants in the Northern Manhattan Study who had a time-of-flight magnetic resonance angiography were included in this analysis (N=1034). A global arterial Z-score, called the brain arterial remodeling (BAR) score, was obtained by averaging the measured diameters within each individual. Individuals with a BAR score <−2 SDs were considered to have the smallest diameters, individuals with a BAR score >−2 and <2 SDs had average diameters, and individuals with a BAR score >2 SDs had the largest diameters. All vascular events were recorded prospectively after the brain magnetic resonance imaging. Spline curves and incidence rates were used to test our hypothesis. The association of the BAR score with death (P=0.001), vascular death (P=0.02), any vascular event (P=0.05), and myocardial infarction (P=0.10) was U-shaped except for ischemic stroke (P=0.74). Consequently, incidence rates for death, vascular death, myocardial infarction, and any vascular event were higher in individuals with the largest diameters, whereas individuals with the smallest diameters had a higher incidence of death, vascular death, any vascular event, and ischemic stroke compared with individuals with average diameters. Conclusions The risk of death, vascular death, and any vascular event increased at both extremes of brain arterial diameters. The pathophysiology linking brain arterial remodeling to systemic vascular events needs further research. PMID:26251284

  1. Replacing 16 mm film cameras with high definition digital cameras

    SciTech Connect

    Balch, K.S.

    1995-12-31

    For many years 16 mm film cameras have been used in severe environments. These film cameras are used on Hy-G automotive sleds, airborne gun cameras, range tracking and other hazardous environments. The companies and government agencies using these cameras are in need of replacing them with a more cost effective solution. Film-based cameras still produce the best resolving capability, however, film development time, chemical disposal, recurring media cost, and faster digital analysis are factors influencing the desire for a 16 mm film camera replacement. This paper will describe a new camera from Kodak that has been designed to replace 16 mm high speed film cameras.

  2. The 19 mm data recorders similarities and differences

    NASA Technical Reports Server (NTRS)

    Atkinson, Steve

    1992-01-01

    Confusion over the use of non-video 19 mm data recorders is becoming more pronounced as we enter the world of high performance computing. This paper addresses the following: the differences between ID-1, ID-2, MIL-STD-2179 and DD-2; what the proper machine is for various applications; how the machine can be integrated into an environment; and any misconceptions there might be about 19 mm tape recorders. DD-2 and 19 mm instrumentation recorders have missions for which each is well designed. While the differences may appear subtle, understanding the difference between the two is the key to picking the right recorder for a particular application.

  3. Manufacturing and optical testing of 800 mm lightweight all C/SiC optics

    NASA Astrophysics Data System (ADS)

    Kaneda, Hidehiro; Naitoh, Masataka; Nakagawa, Takao; Imai, Tadashi; Katayama, Haruyoshi; Suganuma, Masahiro; Tange, Yoshio; Sato, Ryota; Enya, Keigo; Kotani, Masaki; Maruyama, Kenta; Onaka, Takashi; Kokusho, Takuma

    2013-09-01

    Owing to its high specific stiffness and high thermal stability, silicon carbide is one of the materials most suitable for large space-borne optics. Technologies for accurate optical measurements of large optics in the vacuum or cryogenic conditions are also indispensable. Within the framework of the large SiC mirror study program led by JAXA, we manufactured an 800-mm-diameter lightweight telescope, all of which is made of HB-Cesic, a new type of carbon-fiber-reinforced silicon carbide (C/SiC) material developed jointly by ECM, Germany and MELCO, Japan. We first fabricated an 800-mm HB-Cesic primary mirror, and measured the cryogenic deformation of the mirror mounted on an HB-Cesic optical bench in a liquid-helium chamber. We observed the cryo-deformation of 110 nm RMS at 18 K with neither appreciable distortion associated with the mirror support nor significant residual deformation after cooling. We then integrated the primary mirror and a high-order aspheric secondary mirror into a telescope. To evaluate its optical performance, we established a measurement system, which consists of an interferometer in a pressure vessel mounted on a 5-axis adjustable stage, a 900-mm auto-collimating flat mirror, and a flat mirror stand with mechanisms of 2-axis tilt adjustment and rotation with respect to the telescope optical axis. We installed the telescope with the measurement system into the JAXA 6-m chamber and tested them at a vacuum pressure to verify that the system has a sufficiently high tolerance against vibrations in the chamber environment. Finally we conducted a preliminary study of sub-aperture stitching interferometry, which is needed for telescopes of our target missions in this study, by replacing the 900-mm flat mirror with a rotating 300-mm flat mirror.

  4. Dataset for the validation and use of DiameterJ an open source nanofiber diameter measurement tool.

    PubMed

    Hotaling, Nathan A; Bharti, Kapil; Kriel, Haydn; Simon, Carl G

    2015-12-01

    DiameterJ is an open source image analysis plugin for ImageJ. DiameterJ produces ten files for every image that it analyzes. These files include the images that were analyzed, the data to create histograms of fiber radius, pore size, fiber orientation, and summary statistics, as well as images to check the output of DiameterJ. DiameterJ was validated with 130 in silico-derived, digital, synthetic images and 24 scanning electron microscope (SEM) images of steel wire samples with a known diameter distribution. Once validated, DiameterJ was used to analyze SEM images of electrospun polymeric nanofibers, including a comparison of different segmentation algorithms. In this article, all digital synthetic images, SEM images, and their segmentations are included. Additionally, DiameterJ's raw output files, and processed data is included for the reader. The data provided herein was used to generate the figures in DiameterJ: A Validated Open Source Nanofiber Diameter Measurement Tool[1], where more discussion can be found. PMID:26380840

  5. Dataset for the validation and use of DiameterJ an open source nanofiber diameter measurement tool

    PubMed Central

    Hotaling, Nathan A.; Bharti, Kapil; Kriel, Haydn; Simon, Carl G.

    2015-01-01

    DiameterJ is an open source image analysis plugin for ImageJ. DiameterJ produces ten files for every image that it analyzes. These files include the images that were analyzed, the data to create histograms of fiber radius, pore size, fiber orientation, and summary statistics, as well as images to check the output of DiameterJ. DiameterJ was validated with 130 in silico-derived, digital, synthetic images and 24 scanning electron microscope (SEM) images of steel wire samples with a known diameter distribution. Once validated, DiameterJ was used to analyze SEM images of electrospun polymeric nanofibers, including a comparison of different segmentation algorithms. In this article, all digital synthetic images, SEM images, and their segmentations are included. Additionally, DiameterJ’s raw output files, and processed data is included for the reader. The data provided herein was used to generate the figures in DiameterJ: A Validated Open Source Nanofiber Diameter Measurement Tool[1], where more discussion can be found. PMID:26380840

  6. A pilot trial of large versus small diameter needles for oocyte retrieval

    PubMed Central

    2013-01-01

    Background This study was designed to determine whether small diameter needles for oocyte retrieval alter oocyte yields in patients undergoing IVF in comparison to standard large diameter needles. Methods We conducted a prospective pilot study of 21 consecutive favorable prognosis patients. In each patient one ovary was randomly allocated to retrieval with either a 20 G/ 35 mm (thin) or 17 G/ 35 mm (standard) needle, the other ovary was then retrieved with the opposite needle. Results The standard diameter needle was used to collect a total of 215 oocytes from 355 aspirated follicles (60.6%) compared to 203 oocytes from 352 aspirated follicles (57.7%) with the thinner needle (p = 0.23). Stratifying outcomes by anti-Müllerian hormone (AMH), as indicator of ovarian reserve, and by body mass index (BMI) the oocyte yields, still, did not differ (AMH, r (17) = −0.20, p = 0.44; BMI, r (17) =0.02, p = 0.96). Outcomes also did not vary among women with diminished ovarian reserve (p = 0.17) and in women with normal ovarian reserve (p = 1.00). Operating time was, however, significantly increased by 3.3 minutes per ovary (z = −3.08, p = 0.002) with the thinner needle. Conclusions Needle diameter does not affect oocyte yield, including in obese patients and patients with diminished ovarian reserve. Thinner needles appear to significantly prolong operating time. PMID:23510450

  7. Static and dynamic changes in carotid artery diameter in humans during and after strenuous exercise

    PubMed Central

    Studinger, Péter; Lénárd, Zsuzsanna; Kováts, Zsuzsanna; Kocsis, László; Kollai, Mark

    2003-01-01

    Arterial baroreflex function is altered by dynamic exercise, but it is not clear to what extent baroreflex changes are due to altered transduction of pressure into deformation of the barosensory vessel wall. In this study we measured changes in mean common carotid artery diameter and the pulsatile pressure: diameter ratio (PDR) during and after dynamic exercise. Ten young, healthy subjects performed a graded exercise protocol to exhaustion on a bicycle ergometer. Carotid dimensions were measured with an ultrasound wall-tracking system; central arterial pressure was measured with the use of radial tonometry and the generalized transfer function; baroreflex sensitivity (BRS) was assessed in the post-exercise period by spectral analysis and the sequence method. Data are given as means ± s.e.m. Mean carotid artery diameter increased during exercise as compared with control levels, but carotid distension amplitude did not change. PDR was reduced from 27.3 ± 2.7 to 13.7 ± 1.0 μm mmHg−1. Immediately after stopping exercise, the carotid artery constricted and PDR remained reduced. At 60 min post-exercise, the carotid artery dilated and the PDR increased above control levels (33.9 ± 1.4 μm mmHg−1). The post-exercise changes in PDR were closely paralleled by those in BRS (0.74 ≤ r ≤ 0.83, P < 0.05). These changes in mean carotid diameter and PDR suggest that the mean baroreceptor activity level increases during exercise, with reduced dynamic sensitivity; at the end of exercise baroreceptors are suddenly unloaded, then at 1 h post-exercise, baroreceptor activity increases again with increasing dynamic sensitivity. The close correlation between PDR and BRS observed at post-exercise underlies the significance of mechanical factors in arterial baroreflex control. PMID:12766246

  8. Nitrone Cycloadditions of 1,2-Cyclohexadiene

    PubMed Central

    Barber, Joyann S.; Styduhar, Evan D.; Pham, Hung V.; McMahon, Travis C.; Houk, K. N.; Garg, Neil K.

    2016-01-01

    We report the first 1,3-dipolar cycloadditions of 1,2-cyclohexadiene, a rarely exploited strained allene. 1,2-Cyclohexadiene is generated in situ under mild conditions and trapped with nitrones to give isoxazolidine products in synthetically useful yields. The reactions occur regioselectively and exhibit a notable endo preference, thus resulting in the controlled formation of two new bonds and two stereogenic centers. DFT calculations of stepwise and concerted reaction pathways are used to rationalize the observed selectivities. Moreover, the strategic manipulation of nitrone cycloadducts demonstrates the utility of this methodology for the assembly of compounds bearing multiple heterocyclic units. These studies showcase the exploitation of a traditionally avoided reactive intermediate in chemical synthesis. PMID:26854652

  9. Towards higher sensitivity and stability of axon diameter estimation with diffusion‐weighted MRI

    PubMed Central

    Alexander, Daniel C.; Kurniawan, Nyoman D.; Reutens, David C.; Yang, Zhengyi

    2016-01-01

    Diffusion‐weighted MRI is an important tool for in vivo and non‐invasive axon morphometry. The ActiveAx technique utilises an optimised acquisition protocol to infer orientationally invariant indices of axon diameter and density by fitting a model of white matter to the acquired data. In this study, we investigated the factors that influence the sensitivity to small‐diameter axons, namely the gradient strength of the acquisition protocol and the model fitting routine. Diffusion‐weighted ex. vivo images of the mouse brain were acquired using 16.4‐T MRI with high (G max of 300 mT/m) and ultra‐high (G max of 1350 mT/m) gradient strength acquisitions. The estimated axon diameter indices of the mid‐sagittal corpus callosum were validated using electron microscopy. In addition, a dictionary‐based fitting routine was employed and evaluated. Axon diameter indices were closer to electron microscopy measures when higher gradient strengths were employed. Despite the improvement, estimated axon diameter indices (a lower bound of ~ 1.8 μm) remained higher than the measurements obtained using electron microscopy (~1.2 μm). We further observed that limitations of pulsed gradient spin echo (PGSE) acquisition sequences and axonal dispersion could also influence the sensitivity with which axon diameter indices could be estimated. Our results highlight the influence of acquisition protocol, tissue model and model fitting, in addition to gradient strength, on advanced microstructural diffusion‐weighted imaging techniques. © 2016 The Authors. NMR in Biomedicine published by John Wiley & Sons Ltd. PMID:26748471

  10. The Measurements of the Solar Diameter at the Kepler's Times

    NASA Astrophysics Data System (ADS)

    Sigismondi, Costantino; Fraschetti, Federico

    2002-12-01

    We examine five measurements of the solar disk diameter made with a pinhole instrument by Tycho in 1591 and Kepler in 1600-1602 [1]. Those are the first accurate measurements of the solar disk diameter available in literature, even if Ptolemy and Copernicus already did such measurements [2].

  11. Method accurately measures mean particle diameters of monodisperse polystyrene latexes

    NASA Technical Reports Server (NTRS)

    Kubitschek, H. E.

    1967-01-01

    Photomicrographic method determines mean particle diameters of monodisperse polystyrene latexes. Many diameters are measured simultaneously by measuring row lengths of particles in a triangular array at a glass-oil interface. The method provides size standards for electronic particle counters and prevents distortions, softening, and flattening.

  12. Periodically Diameter-Modulated Semiconductor Nanowires for Enhanced Optical Absorption.

    PubMed

    Ko, Minjee; Baek, Seong-Ho; Song, Bokyung; Kang, Jang-Won; Kim, Shin-Ae; Cho, Chang-Hee

    2016-04-01

    A diameter-modulated silicon nanowire array to enhance the optical absorption across broad spectral range is presented. Periodic shape engineering is achieved using conventional semiconductor processes and the unique optical properties are analyzed. The periodicity in the diameter of the silicon nanowires enables stronger and more closely spaced optical resonances, leading to broadband absorption enhancement. PMID:26833855

  13. Building 904, oblique view to northeast, 210mm lens Travis ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 904, oblique view to northeast, 210mm lens - Travis Air Force Base, Base Spares Warehouse No. 1, Dixon Avenue & W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  14. Building 909, oblique view to southeast, 135 mm lens. Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 909, oblique view to southeast, 135 mm lens. Building 908 at extreme right for context. - Travis Air Force Base, Handling Crew Building, North of W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  15. Building 904, oblique view to southeast, 135 mm lens. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 904, oblique view to southeast, 135 mm lens. - Travis Air Force Base, Base Spares Warehouse No. 1, Dixon Avenue & W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  16. Building 904, oblique view to northwest, 135 mm lens ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 904, oblique view to northwest, 135 mm lens - Travis Air Force Base, Base Spares Warehouse No. 1, Dixon Avenue & W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  17. Building 1204, oblique view to east, 90 mm lens. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 1204, oblique view to east, 90 mm lens. - Travis Air Force Base, Squadron Operations & Readiness Crew Facility, W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  18. Building 931, oblique view to southeast, 135 mm lens. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 931, oblique view to southeast, 135 mm lens. - Travis Air Force Base, Central Battery Charging Building, North of W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  19. Building 1204, oblique view to west, 135 mm lens. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 1204, oblique view to west, 135 mm lens. - Travis Air Force Base, Squadron Operations & Readiness Crew Facility, W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  20. Building 931, oblique view to northwest, 210 mm lens. ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 931, oblique view to northwest, 210 mm lens. - Travis Air Force Base, Central Battery Charging Building, North of W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  1. Building 932, oblique view to northwest, 90 mm lens. Building ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Building 932, oblique view to northwest, 90 mm lens. Building 933-935 at extreme left. - Travis Air Force Base, Nuclear Weapons Assembly Plant 5, W Street, Armed Forces Special Weapons Project Q Area, Fairfield, Solano County, CA

  2. OpenMM: A Hardware Independent Framework for Molecular Simulations

    PubMed Central

    Eastman, Peter; Pande, Vijay S.

    2015-01-01

    The wide diversity of computer architectures today requires a new approach to software development. OpenMM is a framework for molecular mechanics simulations, allowing a single program to run efficiently on a variety of hardware platforms. PMID:26146490

  3. 35 mm PHOTOGRAPH TAKEN PRIOR TO DEMOLITION OF STRUCTURE. SOUTH ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    35 mm PHOTOGRAPH TAKEN PRIOR TO DEMOLITION OF STRUCTURE. SOUTH (SIDE) AND EAST (FRONT) ELEVATIONS OF BUILDING. VIEW TO NORTHWEST - Plattsburgh Air Force Base, Gas Station, New York Road, Plattsburgh, Clinton County, NY

  4. High spatial resolution gamma imaging detector based on a 5 inch diameter R3292 Hamamatsu PSPMT

    SciTech Connect

    Wojcik, R.; Majewski, S.; Kross, B.; Weisenberger, A.G.; Steinbach, D.

    1998-06-01

    High resolution imaging gamma-ray detectors were developed using Hamamatsu`s 5 inch diameter R3292 position sensitive PMT (PSPMT) and a variety of crystal scintillator arrays. Special readout techniques were used to maximize the active imaging area while reducing the number of readout channels. Spatial resolutions approaching 1 mm were obtained in a broad energy range from 20 to 511 keV. Results are also presented of coupling the scintillator arrays to the PMT via imaging light guides consisting of acrylic optical fibers.

  5. Development of very small-diameter, inductively coupled magnetized plasma device.

    PubMed

    Kuwahara, D; Mishio, A; Nakagawa, T; Shinohara, S

    2013-10-01

    In order to miniaturize a high-density, inductively coupled magnetized plasma or helicon plasma to be applied to, e.g., an industrial application and an electric propulsion field, small helicon device has been developed. The specifications of this device along with the experimental results are described. We have succeeded in generating high-density (~10(19) m(-3)) plasmas using quartz tubes with very small diameters of 10 and 20 mm, with a radio frequency power ~1200 and 700 W, respectively, in the presence of the magnetic field less than 1 kG. PMID:24182105

  6. Reliable Diameter Control of Carbon Nanotube Nanobundles Using Withdrawal Velocity.

    PubMed

    Shin, Jung Hwal; Kim, Kanghyun; An, Taechang; Choi, WooSeok; Lim, Geunbae

    2016-12-01

    Carbon nanotube (CNT) nanobundles are widely used in nanoscale imaging, fabrication, and electrochemical and biological sensing. The diameter of CNT nanobundles should be controlled precisely, because it is an important factor in determining electrode performance. Here, we fabricated CNT nanobundles on tungsten tips using dielectrophoresis (DEP) force and controlled their diameters by varying the withdrawal velocity of the tungsten tips. Withdrawal velocity pulling away from the liquid-air interface could be an important, reliable parameter to control the diameter of CNT nanobundles. The withdrawal velocity was controlled automatically and precisely with a one-dimensional motorized stage. The effect of the withdrawal velocity on the diameter of CNT nanobundles was analyzed theoretically and compared with the experimental results. Based on the attachment efficiency, the withdrawal velocity is inversely proportional to the diameter of the CNT nanobundles; this has been demonstrated experimentally. Control of the withdrawal velocity will play an important role in fabricating CNT nanobundles using DEP phenomena. PMID:27581602

  7. The 19 mm date recorders: Similarities and differences

    NASA Technical Reports Server (NTRS)

    Atkinson, Steve

    1991-01-01

    Confusion over the use of non-video 19 mm data recorders is becoming more pronounced in the world of high performance computing. The following issues are addressed: (1) the difference between ID-1, ID-2, MIL-STD-2179, and DD-2; (2) the proper machine for the necessary application; and (3) integrating the machine into an existing environment. Also, an attempt is made to clear up any misconceptions there might be about 19 mm tape recorders.

  8. Monolithic mm-wave ICs for smart weapons

    NASA Astrophysics Data System (ADS)

    Duffield, T. L.

    1988-04-01

    An approach to developing a low-cost mm-wave transceiver with application to a broad range of smart weapons systems is described. The proposed transceiver technology consists of monolithic mm-wave integrated circuits on GaAs substrates. The relevant transceiver configurations, FET material, and electron beam lithography are discussed. The types of devices to which the approach is applicable are addressed, emphasizing the use of three-terminal devices for all active elements.

  9. QM/MM investigations of organic chemistry oriented questions.

    PubMed

    Schmidt, Thomas C; Paasche, Alexander; Grebner, Christoph; Ansorg, Kay; Becker, Johannes; Lee, Wook; Engels, Bernd

    2014-01-01

    About 35 years after its first suggestion, QM/MM became the standard theoretical approach to investigate enzymatic structures and processes. The success is due to the ability of QM/MM to provide an accurate atomistic picture of enzymes and related processes. This picture can even be turned into a movie if nuclei-dynamics is taken into account to describe enzymatic processes. In the field of organic chemistry, QM/MM methods are used to a much lesser extent although almost all relevant processes happen in condensed matter or are influenced by complicated interactions between substrate and catalyst. There is less importance for theoretical organic chemistry since the influence of nonpolar solvents is rather weak and the effect of polar solvents can often be accurately described by continuum approaches. Catalytic processes (homogeneous and heterogeneous) can often be reduced to truncated model systems, which are so small that pure quantum-mechanical approaches can be employed. However, since QM/MM becomes more and more efficient due to the success in software and hardware developments, it is more and more used in theoretical organic chemistry to study effects which result from the molecular nature of the environment. It is shown by many examples discussed in this review that the influence can be tremendous, even for nonpolar reactions. The importance of environmental effects in theoretical spectroscopy was already known. Due to its benefits, QM/MM can be expected to experience ongoing growth for the next decade.In the present chapter we give an overview of QM/MM developments and their importance in theoretical organic chemistry, and review applications which give impressions of the possibilities and the importance of the relevant effects. Since there is already a bunch of excellent reviews dealing with QM/MM, we will discuss fundamental ingredients and developments of QM/MM very briefly with a focus on very recent progress. For the applications we follow a similar

  10. Kerosene-water separation in T-junction with orientation upward branch with a 60° angle: Variation of diameter ratio

    NASA Astrophysics Data System (ADS)

    Puspitasari, Dewi; Indarto, Purnomo, Khasani

    2016-06-01

    Research on the T-junction is still underway for the flow of liquid-liquid (kerosene-water). Some research on the characteristics of kerosene-water separation was performed using T-junction oriented upward branch with a 60° angle. To observe the effect of diameters ratio on the phase separation that produced T-junction then made a test section with a horizontal pipe diameter 36 mm, while the side arm 36 mm diameter, 26 mm and 19 mm (diameters ratio of 1, 0.7 and 0.5) by using plexiglass pipe type. Based on experimental results and visualization of data flow in the test section, to the value obtained 60% water cut, the maximum separation efficiency of 94%, FK = 0.94 and FW = 0.001 with a diameter ratio of 1. For other diameter ratio of 0.7 and 0.5 respectively separation efficiency of 66%, FK = 1 and Fw = 0.34 for 0.7 and separation efficiency of 84%, FK = 1 and Fw = 0.16 for 0.5, the best value is obtained at a water cut 60% too. All the best conditions to achieve the above-stratified flow pattern.

  11. Equilibria of 1,1,2,-trichloro-1,2,2-trifluoroethane on activated carbons

    SciTech Connect

    Cho, S.Y.; Lee, Y.Y.

    1995-07-01

    ChloroFluoroCarbons (CFCs) are now considered to be the prime contribution to stratospheric ozone depletion. As a result, the use of activated carbons to adsorb specific CFCs has received great attention. In this paper, the equilibrium adsorption characteristics of 1,1,2-trichloro-1,2,2-trifluoroethane vapor on different-shaped carbons were studied. Adsorption isotherms of 1,2,2-trichloro-1,2,2-trifluoroethane on an activated carbon pellet and an activated carbon felt were measured. The equilibria of 1,1,2-trichloro-1,2,2-trifluoroethane on the activated carbon pellet having a dual pore structure were expressed by the Redlich-Peterson equation, and equilibrium constants were expressed as functions of temperature from 298 to 393 K. On the other hand, the equilibria of 1,1,2-trichloro-1,2,2-trifluoroethane on the activated carbon felt having a relatively uniform pore structure were interpreted by the Dubinin-Radushkevich correlation based on the micropore volume filling theory. The affinity coefficient was correlated by the molar polarization.

  12. 1,1,2-Trichloro-1,2,2-trifluoroethane (CFC-113)

    Integrated Risk Information System (IRIS)

    1,1,2 - Trichloro - 1,2,2 - trifluoroethane ( CFC - 113 ) ; CASRN 76 - 13 - 1 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health

  13. Structural and thermal response of 30 cm diameter ion thruster optics

    NASA Technical Reports Server (NTRS)

    Macrae, G. S.; Zavesky, R. J.; Gooder, S. T.

    1989-01-01

    Tabular and graphical data are presented which are intended for use in calibrating and validating structural and thermal models of ion thruster optics. A 30 cm diameter, two electrode, mercury ion thruster was operated using two different electrode assembly designs. With no beam extraction, the transient and steady state temperature profiles and center electrode gaps were measured for three discharge powers. The data showed that the electrode mount design had little effect on the temperatures, but significantly impacted the motion of the electrode center. Equilibrium electrode gaps increased with one design and decreased with the other. Equilibrium displacements in excess of 0.5 mm and gap changes of 0.08 mm were measured at 450 W discharge power. Variations in equilibrium gaps were also found among assemblies of the same design. The presented data illustrate the necessity for high fidelity ion optics models and development of experimental techniques to allow their validation.

  14. Experimental study on thermal performance of heat sinks: the effect of hydraulic diameter and geometric shape

    NASA Astrophysics Data System (ADS)

    Marzougui, M.; Hammami, M.; Maad, R. Ben

    2015-12-01

    The main purpose of this study is focused on experimental investigation of cooling performance of various minichannel designs. The hydraulic dimension of one of the heat sink is 3 mm while that of the other is 2 mm. Deionised water was used as the coolant for studies conducted in both the heat sinks. Tests were done for a wide range of flow rates (0.7 l-9 l h-1) and heat inputs (5-40 kW/m2). Irrespective of the hydraulic diameter and the geometric configuration, profits and boundaries of each channel shape are analyzed and discussed in the clarity of experimental data. The total thermal resistance and the average heat transfer coefficient are compared for the various channels inspected.

  15. Pupil Diameter Changes in High Myopes after Collamer Lens Implantation

    PubMed Central

    Li, Dan; Yang, Yabo; Su, Caipei; Yin, Houfa; Liu, Xue

    2015-01-01

    ABSTRACT Purpose To observe the changes in pupil size under photopic and scotopic conditions after Implantable Collamer Lens (ICL) implantations in eyes with high myopia. Methods The ICL was implanted in 90 eyes belonging to 45 patients with high myopia. Photopic pupil diameters, scotopic pupil diameters, anterior chamber depths, and ICL vaults were examined at the preoperative, postoperative 1-month, and postoperative 3-month stages. The preoperative and postoperative photopic pupil diameters and scotopic pupil diameters were also compared with each other to note the differences between them. The correlations between preoperative and postoperative pupil diameter changes under different light conditions and presurgical refractive error were analyzed alongside patient’s age and ICL vault. Results Pupil diameters at both postoperative 1-month and postoperative 3-month stages were smaller than those before operation in distinct light environments, as well as pupil constriction amplitude. Correlation analysis showed that there was a statistically significant correlation between pupil diameter changes under different light conditions and presurgical refractive error at 1 month and 3 months after ICL implantation; pupil diameter decreased more when presurgical refractive error powers were less myopic. Statistically significant correlations were not found, however, with patient’s age and ICL vault. Postoperative 1-month and mean postoperative 3-month anterior chamber depths were decreased when compared with preoperative anterior chamber depths. Statistically significant correlations were found in change in preoperative and postoperative anterior chamber depth and ICL vault. No statistically significant difference was found between ICL vault at the postoperative 1-month and postoperative 3-month stages. Conclusions Pupil diameter may decrease at the 1- and 3-month stages after ICL implantation under both photopic and scotopic conditions. This indicates that reduction

  16. Fabrication of ф 160 mm convex hyperbolic mirror for remote sensing instrument

    NASA Astrophysics Data System (ADS)

    Kuo, Ching-Hsiang; Yu, Zong-Ru; Ho, Cheng-Fang; Hsu, Wei-Yao; Chen, Fong-Zhi

    2012-10-01

    In this study, efficient polishing processes with inspection procedures for a large convex hyperbolic mirror of Cassegrain optical system are presented. The polishing process combines the techniques of conventional lapping and CNC polishing. We apply the conventional spherical lapping process to quickly remove the sub-surface damage (SSD) layer caused by grinding process and to get the accurate radius of best-fit sphere (BFS) of aspheric surface with fine surface texture simultaneously. Thus the removed material for aspherization process can be minimized and the polishing time for SSD removal can also be reduced substantially. The inspection procedure was carried out by using phase shift interferometer with CGH and stitching technique. To acquire the real surface form error of each sub aperture, the wavefront errors of the reference flat and CGH flat due to gravity effect of the vertical setup are calibrated in advance. Subsequently, we stitch 10 calibrated sub-aperture surface form errors to establish the whole irregularity of the mirror in 160 mm diameter for correction polishing. The final result of the In this study, efficient polishing processes with inspection procedures for a large convex hyperbolic mirror of Cassegrain optical system are presented. The polishing process combines the techniques of conventional lapping and CNC polishing. We apply the conventional spherical lapping process to quickly remove the sub-surface damage (SSD) layer caused by grinding process and to get the accurate radius of best-fit sphere (BFS) of aspheric surface with fine surface texture simultaneously. Thus the removed material for aspherization process can be minimized and the polishing time for SSD removal can also be reduced substantially. The inspection procedure was carried out by using phase shift interferometer with CGH and stitching technique. To acquire the real surface form error of each sub aperture, the wavefront errors of the reference flat and CGH flat due to

  17. Consecutive Case Series of Healed Single-Molar Sites Immediately Restored with Wide-Diameter Implants: A 1-Year Evaluation

    PubMed Central

    Cherfane, Pierre; Sojod, Bouchra

    2016-01-01

    Introduction. To evaluate outcomes of wide-diameter (6 mm) implants immediately provisionalized with cement-retained single crowns in posterior molar sites. Materials and Methods. Forty-eight consecutive patients received a total of 53 moderately rough-surface, 6 mm diameter implants in healed sites. All implants were immediately provisionalized with a cement-retained provisional crown. Final prosthesis with cement-retained porcelain fused to metal crowns was delivered 3–6 months later. Patients were followed up for 1 year. Outcome measures were implant failures and success rate, complications, marginal bone levels, bone level changes, papilla index, bleeding on probing, and inflammation. Results. One patient was lost to follow-up. At one year, the implant survival and success rate were 98.1%. The mean marginal bone loss after 1 year was −0.17 ± 1.84 mm. Ideal papilla score was recorded at 83.8% of the sites. More than 95.6% of the sites showed no bleeding or inflammation. No procedure-related or device-related adverse events were reported. Conclusion. Wide-diameter (6 mm) implants can safely and successfully replace single posterior molars. Longer follow-up studies are necessary to evaluate the long-term success of these implants. PMID:27195008

  18. Consecutive Case Series of Healed Single-Molar Sites Immediately Restored with Wide-Diameter Implants: A 1-Year Evaluation.

    PubMed

    Antoun, Hadi; Cherfane, Pierre; Sojod, Bouchra

    2016-01-01

    Introduction. To evaluate outcomes of wide-diameter (6 mm) implants immediately provisionalized with cement-retained single crowns in posterior molar sites. Materials and Methods. Forty-eight consecutive patients received a total of 53 moderately rough-surface, 6 mm diameter implants in healed sites. All implants were immediately provisionalized with a cement-retained provisional crown. Final prosthesis with cement-retained porcelain fused to metal crowns was delivered 3-6 months later. Patients were followed up for 1 year. Outcome measures were implant failures and success rate, complications, marginal bone levels, bone level changes, papilla index, bleeding on probing, and inflammation. Results. One patient was lost to follow-up. At one year, the implant survival and success rate were 98.1%. The mean marginal bone loss after 1 year was -0.17 ± 1.84 mm. Ideal papilla score was recorded at 83.8% of the sites. More than 95.6% of the sites showed no bleeding or inflammation. No procedure-related or device-related adverse events were reported. Conclusion. Wide-diameter (6 mm) implants can safely and successfully replace single posterior molars. Longer follow-up studies are necessary to evaluate the long-term success of these implants. PMID:27195008

  19. Spectral Line Survey toward the Young Massive Protostar NGC 2264 CMM3 in the 4 mm, 3 mm, and 0.8 mm Bands

    NASA Astrophysics Data System (ADS)

    Watanabe, Yoshimasa; Sakai, Nami; López-Sepulcre, Ana; Furuya, Ryuta; Sakai, Takeshi; Hirota, Tomoya; Liu, Sheng-Yuan; Su, Yu-Nung; Yamamoto, Satoshi

    2015-08-01

    Spectral line survey observations are conducted toward the high-mass protostar candidate NGC 2264 CMM3 in the 4, 3, and 0.8 mm bands with the Nobeyama 45 m telescope and the Atacama Submillimeter Telescope Experiment (ASTE) 10 m telescope. In total, 265 emission lines are detected in the 4 and 3 mm bands, and 74 emission lines in the 0.8 mm band. As a result, 36 molecular species and 30 isotopologues are identified. In addition to the fundamental molecular species, many emission lines of carbon-chain molecules such as HC5N, C4H, CCS, and C3S are detected in the 4 and 3 mm bands. Deuterated molecular species are also detected with relatively strong intensities. On the other hand, emission lines of complex organic molecules such as HCOOCH3 and CH3OCH3 are found to be weak. For the molecules for which multiple transitions are detected, rotation temperatures are derived to be 7-33 K except for CH3OH. Emission lines with high upper-state energies (Eu > 150 K) are detected for CH3OH, indicating the existence of a hot core. In comparison with the chemical composition of the Orion KL, carbon-chain molecules and deuterated molecules are found to be abundant in NGC 2264 CMM3, while sulfur-bearing species and complex organic molecules are deficient. These characteristics indicate the chemical youth of NGC 2264 CMM3 in spite of its location at the center of the cluster forming core, NGC 2264 C.

  20. Performance of 0. 75 mm pitch MWPC'S operating at high rate

    SciTech Connect

    Conetti, S.; Kuzminski, J.; Marchionni, A.; Stairs, D.; Arenton, M.; Chen, T.Y.; Cox, B.; Delchamps, S.; Etemadi, B.; Fortney, L.

    1989-01-01

    Three Multiwire Proportional Chambers (MWPC) with high rate capability have been constructed for Fermi National Accelerator Laboratory experiment 705 (Charmonium and Direct Photon production by ..pi../sup +-/, p and /bar p/ at 300 GeV/c). Each chamber, with a sensitive area of 308 cm/sup 2/, consists of three anode planes, wound with 12.5 ..mu..m diameter gold-plated tungsten/rhenium wire, facing 25 ..mu..m graphite-coated kapton cathode planes at a distance of 3 mm. Wire spacing in two of the MWPC (PC-B1 and PC-B2) is 0.75 mm and 1.00 mm in the third one (PC-B3). After a few weeks of running on ''Magic Gas'' with a beam flux of up to /approximately/10/sup 7/ particles/cm/sup 2/sec, severe damage occurred to the graphite coating. All cathode planes were replaced by aluminized kapton, and the chambers worked successfully for the next 3 months until the end of the run, when a 10% efficiency drop was observed after a total accumulated charge of /approximately/1 C/cm of sense wire. After the end of the run the chambers were disassembled and inspected. A white deposit with a characteristic ''wire pattern'' etched away from the Al coating was observed in the region of the beam spot. 10 refs., 8 figs., 1 tab.

  1. U-vein compressor improves early haemodynamic outcomes in radiocephalic arterio-venous fistulae in under 2-mm superficial veins

    PubMed Central

    Seren, Mustafa; Cicek, Omer Faruk; Cicek, Mustafa Cuneyt; Yener, Ali Umit; Ulaş, Mahmut; Tola, Muharrem; Uzun, Alper

    2015-01-01

    Summary Aim In this study, we sought to determine the early postoperative results of arterio-venous fistulae (AVF) created by U-vein compressors with veins between 1.5 and 2 mm in size. Methods Pre-operative venous mapping was done. The fistula tract was marked at 0-, 4-, 8- and 12-cm points; 0 cm was the estimated point where the anastomosis would be done. With Doppler ultrasonography, transverse diameters in the estimated fistula tract were measured at the 0-, 4-, 8- and 12-cm points. A superficial vein that would be used as the fistula tract was dilated using U-vein compressors. In the first postoperative hour, the flow in the anastomosis, and the transverse diameter of the fistula tract at the 0-, 4-, 8- and 12-cm points were measured by Doppler ultrasonography. Results Forty patients were included in the study. U-vein compressors were used for 20 patients. Postoperative expansion of vein diameters and postoperative flow velocities were found to be statistically significantly different in patients where a U-vein compressor had been used (p < 0.001). Conclusion We present a technique to dilate veins that are between 1.5 and 2 mm in diameter, which are generally accepted as poor vessels to create radiocephalic arteriovenous fistulae. PMID:25784317

  2. Design report for an indirectly cooled 3-m diameter superconducting solenoid for the Fermilab Collider Detector Facility

    SciTech Connect

    Fast, R.; Grimson, J.; Kephart, R.

    1982-10-01

    The Fermilab Collider Detector Facility (CDF) is a large detector system designed to study anti pp collisions at very high center of mass energies. The central detector for the CDF shown employs a large axial magnetic field volume instrumented with a central tracking chamber composed of multiple layers of cylindrical drift chambers and a pair of intermediate tracking chambers. The purpose of this system is to determine the trajectories, sign of electric charge, and momenta of charged particles produced with polar angles between 10 and 170 degrees. The magnetic field volume required for tracking is approximately 3.5 m long an 3 m in diameter. To provide the desired ..delta..p/sub T/p/sub T/ less than or equal to 1.5% at 50 GeV/c using drift chambers with approx. 200..mu.. resolution the field inside this volume should be 1.5 T. The field should be as uniform as is practical to simplify both track finding and the reconstruction of particle trajectories with the drift chambers. Such a field can be produced by a cylindrical current sheet solenoid with a uniform current density of 1.2 x 10/sup 6/ A/m (1200 A/mm) surrounded by an iron return yoke. For practical coils and return yokes, both central electromagnetic and central hadronic calorimetry must be located outside the coil of the magnet. This geometry requires that the coil and the cryostat be thin both in physical thickness and in radiation and absorption lengths. This dual requirement of high linear current density and minimal coil thickness can only be satisfied using superconducting technology. In this report we describe the design for an indirectly cooled superconducting solenoid to meet the requirements of the Fermilab CDF. The components of the magnet system are discussed in the following chapters, with a summary of parameters listed in Appendix A.

  3. THE MAGNETIC FIELD MORPHOLOGY OF THE CLASS 0 PROTOSTAR L1157-mm

    SciTech Connect

    Stephens, Ian W.; Looney, Leslie W.; Kwon, Woojin; Crutcher, Richard M.; Hull, Charles L. H.; Plambeck, Richard L.; Chapman, Nicholas; Novak, Giles; Matthews, Tristan; Davidson, Jacqueline; Vaillancourt, John E.; Shinnaga, Hiroko

    2013-05-20

    We present the first detection of polarization around the Class 0 low-mass protostar L1157-mm at two different wavelengths. We show polarimetric maps at large scales (10'' resolution at 350 {mu}m) from the SHARC-II Polarimeter and at smaller scales (1.''2-4.''5 at 1.3 mm) from the Combined Array for Research in Millimeter-wave Astronomy (CARMA). The observations are consistent with each other and show inferred magnetic field lines aligned with the outflow. The CARMA observations suggest a full hourglass magnetic field morphology centered about the core; this is only the second well-defined hourglass detected around a low-mass protostar to date. We apply two different methods to CARMA polarimetric observations to estimate the plane-of-sky magnetic field magnitude, finding values of 1.4 and 3.4 mG.

  4. Renal Artery Embolization Combined With Radiofrequency Ablation in a Porcine Kidney Model: Effect of Small and Narrowly Calibrated Microparticles as Embolization Material on Coagulation Diameter, Volume, and Shape

    SciTech Connect

    Sommer, C. M. Kortes, N.; Zelzer, S.; Arnegger, F. U.; Stampfl, U.; Bellemann, N.; Gehrig, T.; Nickel, F.; Kenngott, H. G.; Mogler, C.; Longerich, T.; Meinzer, H. P.; Richter, G. M.; Kauczor, H. U.; Radeleff, B. A.

    2011-02-15

    The purpose of this study was to evaluate the effect of renal artery embolization with small and narrowly calibrated microparticles on the coagulation diameter, volume, and shape of radiofrequency ablations (RFAs) in porcine kidneys. Forty-eight RFAs were performed in 24 kidneys of 12 pigs. In 6 animals, bilateral renal artery embolization was performed with small and narrowly calibrated microparticles. Upper and lower kidney poles were ablated with identical system parameters. Applying three-dimensional segmentation software, RFAs were segmented on registered 2 mm-thin macroscopic slices. Length, depth, width, volume{sub s}egmented, and volume{sub c}alculated were determined to describe the size of the RFAs. To evaluate the shape of the RFAs, depth-to-width ratio (perfect symmetry-to-lesion length was indicated by a ratio of 1), sphericity ratio (perfect sphere was indicated by a sphericity ratio of 1), eccentricity (perfect sphere was indicated by an eccentricity of 0), and circularity (perfect circle was indicated by a circularity of 1) were determined. Embolized compared with nonembolized RFAs showed significantly greater depth (23.4 {+-} 3.6 vs. 17.2 {+-} 1.8 mm; p < 0.001) and width (20.1 {+-} 2.9 vs. 12.6 {+-} 3.7 mm; p < 0.001); significantly larger volume{sub s}egmented (8.6 {+-} 3.2 vs. 3.0 {+-} 0.7 ml; p < 0.001) and volume{sub c}alculated (8.4 {+-} 3.0 ml vs. 3.3 {+-} 1.1 ml; p < 0.001); significantly lower depth-to-width (1.17 {+-} 0.10 vs. 1.48 {+-} 0.44; p < 0.05), sphericity (1.55 {+-} 0.44 vs. 1.96 {+-} 0.43; p < 0.01), and eccentricity (0.84 {+-} 0.61 vs. 1.73 {+-} 0.91; p < 0.01) ratios; and significantly greater circularity (0.62 {+-} 0.14 vs. 0.45 {+-} 0.16; p < 0.01). Renal artery embolization with small and narrowly calibrated microparticles affected the coagulation diameter, volume, and shape of RFAs in porcine kidneys. Embolized RFAs were significantly larger and more spherical compared with nonembolized RFAs.

  5. Valve-in-valve implantation with a 23-mm balloon-expandable transcatheter heart valve for the treatment of a 19-mm stentless bioprosthesis severe aortic regurgitation using a strategy of "extreme" underfilling.

    PubMed

    Chevalier, Florent; Leipsic, Jonathon; Généreux, Philippe

    2014-09-01

    We report a case of valve-in-valve (ViV) implantation by transfemoral approach with a 23-mm balloon-expandable prosthesis inside a stentless 19-mm acutely degenerated bioprosthesis, using a strategy of "extreme" underfilling. A 74-year-old patient presented to our institution in cardiogenic shock. An initial transesophageal echocardiography (TEE) showed severe central aortic regurgitation (AR) due to a torn leaflet. She was deemed inoperable and considered for urgent transcatheter aortic valve replacement. Given the fairly small true internal diameter, a strategy of 3-cc underfilling of a 23-mm transcatheter heart valve (THV) was planned. However, the final implantation was performed with 5-cc underfilling due to the incapacity to deliver the entire amount of fluid contained in the inflation syringe. TEE guidance confirmed the successful positioning and deployment of the prosthesis, with no AR and a mean gradient of 25 mm Hg. While implantation of a smaller prosthesis (20 mm) was debated during the Heart Team discussion, the risk of valve embolization due to inadequate anchoring inside the stentless prosthesis led to the selection of a 23-mm THV. At 6-month follow-up, the patient was in NYHA class I, with no AR and a mean gradient of 28 mm Hg. We report for the first time the use of in vivo THV with 5-cc underfilling with no acute or short-term structural failure, and the first ViV implantation by transfemoral approach with a 23-mm balloon-expandable prosthesis inside a stentless 19-mm bioprosthesis. The current report presents the challenges related to ViV implantation inside a small stentless bioprosthesis and offers practical ways to overcome them. © 2014 Wiley Periodicals, Inc. PMID:24402706

  6. Synthesis and characterization of polycaprolactone urethane hollow fiber membranes as small diameter vascular grafts.

    PubMed

    Mercado-Pagán, Ángel E; Stahl, Alexander M; Ramseier, Michelle L; Behn, Anthony W; Yang, Yunzhi

    2016-07-01

    The design of bioresorbable synthetic small diameter (<6mm) vascular grafts (SDVGs) capable of sustaining long-term patency and endothelialization is a daunting challenge in vascular tissue engineering. Here, we synthesized a family of biocompatible and biodegradable polycaprolactone (PCL) urethane macromers to fabricate hollow fiber membranes (HFMs) as SDVG candidates, and characterized their mechanical properties, degradability, hemocompatibility, and endothelial development. The HFMs had smooth surfaces and porous internal structures. Their tensile stiffness ranged from 0.09 to 0.11N/mm and their maximum tensile force from 0.86 to 1.03N, with minimum failure strains of approximately 130%. Permeability varied from 1 to 14×10(-6)cm/s, burst pressures from 1158 to 1468mmHg, and compliance from 0.52 to 1.48%/100mmHg. The suture retention forces ranged from 0.55 to 0.81N. HFMs had slow degradation profiles, with 15 to 30% degradation after 8weeks. Human endothelial cells proliferated well on the HFMs, creating stable cell layer coverage. Hemocompatibility studies demonstrated low hemolysis (<2%), platelet activation, and protein adsorption. There were no significant differences in the hemocompatibility of HFMs in the absence and presence of endothelial layers. These encouraging results suggest great promise of our newly developed materials and biodegradable elastomeric HFMs as SDVG candidates. PMID:27127029

  7. Stereodynamics of small 1,2-dialkyldiaziridines.

    PubMed

    Kamuf, Matthias; Trapp, Oliver

    2013-04-01

    Diaziridines are very interesting representatives of organic compounds containing stereogenic nitrogen atoms. In particular, 1,2-dialkyldiaziridines show extraordinarily high stereointegrity. The lone electron pairs of the nitrogen atoms are in trans configuration, avoiding a four-electron repulsive interaction. Furthermore, the trans configuration of the substituents at the nitrogen atoms is energetically favored because of reduced steric interactions. Therefore only two stereoisomers (enantiomers) are observed. At elevated temperatures the enantiomers are interconverting because of the limited stereointegrity of the chirotopic nitrogen atoms. The enantiomerization rate constants and the activation parameters of interconversion are of great interest. Here, we investigated the stereodynamics of a set of small 1,2-dialkyldiaziridines bearing short substituents (Me, Et, iPr, tBu), using enantioselective dynamic gas chromatography (DGC). Separation of enantiomers of all compounds, including the highly volatile 1,2-dimethyldiaziridine, was achieved using heptakis(2,3-di-O-ethyl-6-O-tert-butyldimethylsilyl)-β-cyclodextrin in 50% PS086 (w/w) as chiral stationary phase in fused silica capillaries with a length of up to 50 m. Measurements at variable temperatures were performed and reaction rate constants were determined using the unified equation of chromatography implemented in the software DCXplorer. The activation barriers at room temperature for 1-(tert-butyl)-2-ethyldiaziridine, ΔG(╪)(298K) = 123.8 kJ mol(-1) (ΔH(╪) = 115.5±2.9 kJ mol(-1), ΔS(╪) = -28±1 J mol(-1) K(-1)), and 1-ethyl-2-isopropyldiaziridine, ΔG(╪)(298K) = 124.2 kJ mol(-1) (ΔH(╪) = 113.1±2.4 kJ mol(-1), ΔS(╪) = -37±2 J mol(-1) K(-1)), were determined, representing some of the highest values observed for nitrogen inversion in diaziridines. PMID:23401088

  8. (1+2)-dimensional strongly nonlocal solitons

    SciTech Connect

    Ouyang Shigen; Guo Qi

    2007-11-15

    Approximate solutions of (1+2)-dimensional strongly nonlocal solitons (SNSs) are presented. It is shown that the power of a SNS in a nematic liquid crystal is in direct proportion to the second power of the degree of nonlocality, the power of a SNS in a nonlocal medium with a logarithmic nonlocal response is in inverse proportion to the second power of its beamwidth, and the power of a SNS in a nonlocal medium with an sth-power decay nonlocal response is in direct proportion to the (s+2)th power of the degree of nonlocality.

  9. Spin-1/2 Optical Lattice Clock

    SciTech Connect

    Lemke, N. D.; Ludlow, A. D.; Barber, Z. W.; Fortier, T. M.; Diddams, S. A.; Jiang, Y.; Jefferts, S. R.; Heavner, T. P.; Parker, T. E.; Oates, C. W.

    2009-08-07

    We experimentally investigate an optical clock based on {sup 171}Yb (I=1/2) atoms confined in an optical lattice. We have evaluated all known frequency shifts to the clock transition, including a density-dependent collision shift, with a fractional uncertainty of 3.4x10{sup -16}, limited principally by uncertainty in the blackbody radiation Stark shift. We measured the absolute clock transition frequency relative to the NIST-F1 Cs fountain clock and find the frequency to be 518 295 836 590 865.2(0.7) Hz.

  10. Sterilization of various diameter dead-ended tubes.

    PubMed

    Young, J H

    1993-06-01

    Effect of tube diameter on steam-in-place sterilization of dead-ended tubes was studied by examining temperature profiles and rates of kill of Bacillus stearothermophilus spores. Time required for sterilization was determined for 9.4-cm-long tubes with various inside diameters from 0.4 to 1.7 cm. Sterilization time increased with decreasing tube diameter. Experimentally measured kill kinetics in 1.7-cm tubes were in agreement with those predicted if measured temperatures represented saturated steam. A 12-log spore reduction was achieved in 1.7-cm diameter vertical and horizontal tubes in less than 63 minutes. For smaller diameter tubes, entrapped air remained after 2 hours and rates of kill were very dependent on position within the tube, tube diameter, and tube orientation with respect to the gravitational vector. Times to achieve a 1-log drop in spore population in the smaller tubes were as much as 10 times greater than those expected if measured temperatures represented saturated steam. Sterilization was not achieved throughout the 0.4-cm tubes. Recommendations are made for including steam bleeders or using prevaccum cycles for these smaller diameter tubes. PMID:18609656

  11. Increased Arterial Diameters in the Posterior Cerebral Circulation in Men with Fabry Disease

    PubMed Central

    Üçeyler, Nurcan; Homola, György A.; Guerrero González, Hans; Kramer, Daniela; Wanner, Christoph; Weidemann, Frank; Solymosi, László; Sommer, Claudia

    2014-01-01

    A high load of white matter lesions and enlarged basilar arteries have been shown in selected patients with Fabry disease, a disorder associated with an increased stroke risk. We studied a large cohort of patients with Fabry disease to differentially investigate white matter lesion load and cerebral artery diameters. We retrospectively analyzed cranial magnetic resonance imaging scans of 87 consecutive Fabry patients, 20 patients with ischemic stroke, and 36 controls. We determined the white matter lesion load applying the Fazekas score on fluid-attenuated inversion recovery sequences and measured the diameters of cerebral arteries on 3D-reconstructions of the time-of-flight-MR-angiography scans. Data of different Fabry patient subgroups (males – females; normal – impaired renal function) were compared with data of patients with stroke and controls. A history of stroke or transient ischemic attacks was present in 4/30 males (13%) and 5/57 (9%) females with Fabry disease, all in the anterior circulation. Only one man with Fabry disease showed confluent cerebral white matter lesions in the Fazekas score assessment (1%). Male Fabry patients had a larger basilar artery (p<0.01) and posterior cerebral artery diameter (p<0.05) compared to male controls. This was independent of disease severity as measured by renal function and did not lead to changes in arterial blood flow properties. A basilar artery diameter of >3.2 mm distinguished between men with Fabry disease and controls (sensitivity: 87%, specificity: 86%, p<0.001), but not from stroke patients. Enlarged arterial diameters of the posterior circulation are present only in men with Fabry disease independent of disease severity. PMID:24475221

  12. Influence of lubricant oil on heat transfer performance of refrigerant flow boiling inside small diameter tubes. Part II: Correlations

    SciTech Connect

    Wei, Wenjian; Ding, Guoliang; Hu, Haitao; Wang, Kaijian

    2007-10-15

    The predictive ability of the available state-of-the-art heat transfer correlations of refrigerant-oil mixture is evaluated with the present experiment data of small tubes with inside diameter of 6.34 mm and 2.50 mm. Most of these correlations can be used to predict the heat transfer coefficient of 6.34 mm tube, but none of them can predict heat transfer coefficient of 2.50 mm tube satisfactorily. A new correlation of two-phase heat transfer multiplier with local properties of refrigerant-oil mixture is developed. This correlation approaches the actual physical mechanism of flow boiling heat transfer of refrigerant-oil mixture and can reflect the actual co-existing conditions of refrigerant and lubricant oil. More than 90% of the experiment data of both test tubes have less than {+-}20% deviation from the prediction values of the new correlations. (author)

  13. Removal of fusain with a small-diameter H.M. cyclone operating with ultrafine medium particles

    SciTech Connect

    Xu Jianping Cai Changfeng; Zhang Jing

    1997-12-31

    As evidenced by study of physio-chemical property and liberation characteristics of the macerals of Shenfu young coal, the vitrain differs slightly with fusain in density, with the density of the former being about 0.1g/l higher. After being crushed to {minus}0.5mm, the individual maceral can be liberated, and the fusainite content in the {minus}0.043mm size fraction is noticeably higher than that in the 0.5--0.043mm size fraction. Based on the theory and practical cleaning result obtained through using a small-diameter cyclone for efficient cleaning of fine coal according to density, tests on the removal of fusain from 0.5--0.043mm size coal were conducted with a small-size cyclone operating with ultrafine medium. The test proved to be successful, with a fusain removal rate of up to 50%.

  14. 3-nitro-1,2,4-triazol-5-one, a less sensitive explosive

    DOEpatents

    Lee, Kien-Yin; Coburn, Michael D.

    1988-01-01

    A less sensitive explosive, 3-nitro-1,2,4-triazol-5-one. The compound 3-nitro-1,2,4-triazol-5-one (NTO) has a crystal density of 1.93 g/cm.sup.3 and calculated detonation velocity and pressure equivalent to those of RDX. It can be prepared in high yield from inexpensive starting materials in a safe synthesis. Results from initial small-scale sensitivity tests indicate that NTO is less sensitive than RDX and HMX in all respects. A 4.13 cm diameter, unconfined plate-dent test at 92% of crystal density gave the detonation pressure predicted for NTO by the BKW calculation.

  15. Effects of diameter and temperature on XTX-8004 detonation velocity

    SciTech Connect

    Campos, C.A.

    1980-10-01

    This study was performed to determine the dependence of XTX-8004 steady detonation velocity on charge diameter and temperature. The tests were performed for four different diameters at three temperatures using a standard 4-track detonation velocity block and corresponding printed circuit ionization switch plate. The explosive was loaded in the detonation velocity block to a nominal density of 1.553 g/cc. Measurements obtained from two samples per temperature indicate the critical diameter is less than 0.178 cm. A relationship between detonation velocity and density due to temperature was established using experimental measurements.

  16. Calibration of the radiometric asteroid scale using occultation diameters

    NASA Technical Reports Server (NTRS)

    Telesco, C. M.; Brunk, W. E.; Brown, R. H.; Morrison, D.

    1982-01-01

    The paper describes a new approach to the calibration of the radiometric asteroid scale, which relies on recent accurate occultation measurements of the diameters of 2 Pallas (Wasserman et al., 1979) and 3 Juno (Millis et al., 1981), and the Voyager diameter of J4 Callisto, as well as IR photometry of these objects obtained with the NASA 3-m Infrared Telescope Facility. It is shown that this calibration is internally consistent to better than 5%, and probably has an absolute accuracy of + or - 5%. It is noted that a revision of the TRIAD radiometric diameters downward is required to bring them into agreement with the new calibration.

  17. Thermal mechanical analyses of large diameter ion accelerator systems

    SciTech Connect

    Brophy, J.R.; Aston, G.

    1989-01-01

    Thermal mechanical analyses of large diameter ion accelerator systems are performed using commercially available finite element software executed on a desktop computer. Finite element models of a 30-cm-diameter accelerator system formulated using plate/shell elements give calculated results which agree well with similar published obtained on a mainframe computer. Analyses of a 50-cm-diameter, three-grid accelerator system using measured grid temperatures (corresponding to discharge powers of 653 and 886 watts) indicate that thermally induced grid movements need not be the performance limiting phenomena for accelerator systems of this size. 8 refs.

  18. Thermal mechanical analyses of large diameter ion accelerator systems

    NASA Technical Reports Server (NTRS)

    Brophy, John R.; Aston, Graeme

    1989-01-01

    Thermal mechanical analyses of large diameter ion accelerator systems are performed using commercially available finite element software executed on a desktop computer. Finite element models of a 30-cm-diameter accelerator system formulated using plate/shell elements give calculated results which agree well with similar published obtained on a mainframe computer. Analyses of a 50-cm-diameter, three-grid accelerator system using measured grid temperatures (corresponding to discharge powers of 653 and 886 watts) indicate that thermally induced grid movements need not be the performance limiting phenomena for accelerator systems of this size.

  19. QM/MM calculations with deMon2k.

    PubMed

    Salahub, Dennis R; Noskov, Sergei Yu; Lev, Bogdan; Zhang, Rui; Ngo, Van; Goursot, Annick; Calaminici, Patrizia; Köster, Andreas M; Alvarez-Ibarra, Aurelio; Mejía-Rodríguez, Daniel; Řezáč, Jan; Cailliez, Fabien; de la Lande, Aurélien

    2015-01-01

    The density functional code deMon2k employs a fitted density throughout (Auxiliary Density Functional Theory), which offers a great speed advantage without sacrificing necessary accuracy. Powerful Quantum Mechanical/Molecular Mechanical (QM/MM) approaches are reviewed. Following an overview of the basic features of deMon2k that make it efficient while retaining accuracy, three QM/MM implementations are compared and contrasted. In the first, deMon2k is interfaced with the CHARMM MM code (CHARMM-deMon2k); in the second MM is coded directly within the deMon2k software; and in the third the Chemistry in Ruby (Cuby) wrapper is used to drive the calculations. Cuby is also used in the context of constrained-DFT/MM calculations. Each of these implementations is described briefly; pros and cons are discussed and a few recent applications are described briefly. Applications include solvated ions and biomolecules, polyglutamine peptides important in polyQ neurodegenerative diseases, copper monooxygenases and ultra-rapid electron transfer in cryptochromes. PMID:25786164

  20. The same-source parallel MM{sub 5}.

    SciTech Connect

    Michalakes, J.

    1999-08-23

    The set of architectures available to users of the Penn State/NCAR MM5 has been expanded to included distributed-memory parallel computers, providing cost-effective scalable performance and memory capacity for large problem sizes. The same-source approach uses high-level parallel library and source-translation technology for adapting MM5, simplifying maintenance and allowing new physics modules to be incorporated without modification. The approach facilitates maintenance of the DM-parallel option to MM5 as an option within the official version, rather than as a separate stand-alone version. As a result, the DM-parallel option to MM5 (now at Version 3.1) has been a part of six subsequent model releases since MM5 Version 2.8 in March 1998. The same-source approach is applicable to other, similarly constructed codes when there is a need or desire to develop the code for distributed memory parallel machines without impacting the pre-existing source code. The approach is also compatible with pre-existing loop-level multithreading directives so that the code will run in distributed-memory/shared-memory mode on SMP clusters.

  1. CMOS mm-wave transceivers for Gbps wireless communication

    NASA Astrophysics Data System (ADS)

    Baoyong, Chi; Zheng, Song; Lixue, Kuang; Haikun, Jia; Xiangyu, Meng; Zhihua, Wang

    2016-07-01

    The challenges in the design of CMOS millimeter-wave (mm-wave) transceiver for Gbps wireless communication are discussed. To support the Gbps data rate, the link bandwidth of the receiver/transmitter must be wide enough, which puts a lot of pressure on the mm-wave front-end as well as on the baseband circuit. This paper discusses the effects of the limited link bandwidth on the transceiver system performance and overviews the bandwidth expansion techniques for mm-wave amplifiers and IF programmable gain amplifier. Furthermore, dual-mode power amplifier (PA) and self-healing technique are introduced to improve the PA's average efficiency and to deal with the process, voltage, and temperature variation issue, respectively. Several fully-integrated CMOS mm-wave transceivers are also presented to give a short overview on the state-of-the-art mm-wave transceivers. Project supported in part by the National Natural Science Foundation of China (No. 61331003).

  2. The brightness temperature of Mercury at mm-wavelengths

    NASA Astrophysics Data System (ADS)

    Greve, A.; Thum, C.; Moreno, R.; Yan, N.

    2009-02-01

    We present observations of Mercury made with the IRAM 30-m telescope at 3, 2 and 1.3 mm wavelength (90, 150 and 230 GHz) during the years 1985-2005; we derive from these data the disk-averaged brightness temperatures. The observations at 3 mm combined with those by Epstein & Andrew allow a separation of the data into 40° wide longitude intervals and by this an investigation of the disk-averaged brightness temperature with Mercury's longitude. From the new mm-wavelength data, and data taken from the literature, we derive the disk-averaged brightness temperature as a function of wavelength. On Mercury's night side a significant decrease in brightness temperature occurs towards shorter wavelengths. We use the three surface models (A,B,C) discussed by Mitchell & de Pater and calculate for the cool and hot surface region the corrresponding diurnal variation of the disk-averaged brightness temperature at 90 GHz. For the same models we calculate the variation of the disk-averaged brightness temperature with wavelength between 1.3 mm and 37 mm, on Mercury's midnight side and noon side. Although the scatter in the observations is large, there seems to be a marginally better agreement with model B and A.

  3. A 5-mm piezo-scanning fiber device for high speed ultrafast laser microsurgery

    PubMed Central

    Ferhanoglu, Onur; Yildirim, Murat; Subramanian, Kaushik; Ben-Yakar, Adela

    2014-01-01

    Towards developing precise microsurgery tools for the clinic, we previously developed image-guided miniaturized devices using low repetition rate amplified ultrafast lasers for surgery. To improve the speed of tissue removal while reducing device diameter, here we present a new 5-mm diameter device that delivers high-repetition rate laser pulses for high speed ultrafast laser microsurgery. The device consists of an air-core photonic bandgap fiber (PBF) for the delivery of high energy pulses, a piezoelectric tube actuator for fiber scanning, and two aspheric lenses for focusing the light. Its inline optical architecture provides easy alignment and substantial size reduction to 5 mm diameter as compared to our previous MEMS-scanning devices while realizing improved intensity squared (two-photon) lateral and axial resolutions of 1.16 μm and 11.46 μm, respectively. Our study also sheds light on the maximum pulse energies that can be delivered through the air-core PBF and identifies cladding damage at the input facet of the fiber as the limiting factor. We have achieved a maximum energy delivery larger than 700 nJ at 92% coupling efficiency. An in depth analysis reveals how this value is greatly affected by possible slight misalignments of the beam during coupling and the measured small beam pointing fluctuations. In the absence of these imperfections, self-phase modulation becomes the limiting factor for the maximum energy delivery, setting the theoretical upper bound to near 2 μJ for a 1-m long, 7-μm, air-core PBF. Finally, the use of a 300 kHz repetition rate fiber laser enabled rapid ablation of 150 µm x 150 µm area within only 50 ms. Such ablation speeds can now allow the surgeons to translate the surgery device as fast as ~4 mm/s to continuously remove a thin layer of a 150 µm wide tissue. Thanks to a high optical transmission efficiency of the in-line optical architecture of the device and improved resolution, we could successfully perform ablation of

  4. A 5-mm piezo-scanning fiber device for high speed ultrafast laser microsurgery.

    PubMed

    Ferhanoglu, Onur; Yildirim, Murat; Subramanian, Kaushik; Ben-Yakar, Adela

    2014-07-01

    Towards developing precise microsurgery tools for the clinic, we previously developed image-guided miniaturized devices using low repetition rate amplified ultrafast lasers for surgery. To improve the speed of tissue removal while reducing device diameter, here we present a new 5-mm diameter device that delivers high-repetition rate laser pulses for high speed ultrafast laser microsurgery. The device consists of an air-core photonic bandgap fiber (PBF) for the delivery of high energy pulses, a piezoelectric tube actuator for fiber scanning, and two aspheric lenses for focusing the light. Its inline optical architecture provides easy alignment and substantial size reduction to 5 mm diameter as compared to our previous MEMS-scanning devices while realizing improved intensity squared (two-photon) lateral and axial resolutions of 1.16 μm and 11.46 μm, respectively. Our study also sheds light on the maximum pulse energies that can be delivered through the air-core PBF and identifies cladding damage at the input facet of the fiber as the limiting factor. We have achieved a maximum energy delivery larger than 700 nJ at 92% coupling efficiency. An in depth analysis reveals how this value is greatly affected by possible slight misalignments of the beam during coupling and the measured small beam pointing fluctuations. In the absence of these imperfections, self-phase modulation becomes the limiting factor for the maximum energy delivery, setting the theoretical upper bound to near 2 μJ for a 1-m long, 7-μm, air-core PBF. Finally, the use of a 300 kHz repetition rate fiber laser enabled rapid ablation of 150 µm x 150 µm area within only 50 ms. Such ablation speeds can now allow the surgeons to translate the surgery device as fast as ~4 mm/s to continuously remove a thin layer of a 150 µm wide tissue. Thanks to a high optical transmission efficiency of the in-line optical architecture of the device and improved resolution, we could successfully perform ablation of

  5. Correlation of anterior segment optical coherence tomography measurements with graft trephine diameter following descemet stripping automated endothelial keratoplasty

    PubMed Central

    2012-01-01

    Background To assess repeatability of the Zhongshan Assessment Program (ZAP) software measurement of Anterior Segment Optical Coherence Tomography (ASOCT) images and correlate with graft trephine diameter following Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) Methods Retrospectively evaluated interventional case series. 121 consecutive eyes undergoing DSAEK over a 26 month period underwent ASOCT imaging 1month after their surgery. ASOCT images were processed using ZAP software which measured the graft and cornea parameters including anterior and posterior graft arc length and cord length, posterior cornea arc length (PCAL) and anterior chamber width. Results The graft measurements showed good repeatability on ASOCT using ZAP with high intra class coefficient and small variation in the coefficient of variation. On ASOCT, the mean recipient PCAL was 12.99+/−0.69mm and the anterior chamber width was 11.16+/−0.57mm. The mean Graft anterior arc length was 9.69+/−0.66mm and the mean Graft anterior cord length was 8.92+/−2.94mm. The mean graft posterior arc length was 9.24+/−0.75mm and the mean graft posterior cord length was 8.15+/−0.57mm. Graft posterior arc length (rho=0.788, p< 0.001) correlated best with intra-operative graft trephine diameter. The mean ratio of posterior graft arc length to PCAL was 0.712 +/− 0.056. Conclusions We have validated the repeatability of the ZAP software for DSAEK graft measurements from ASOCT images and shown that the graft arc length parameters calculated from the ASOCT images correlate well with the intra-operative graft trephine diameter. This software may help surgeons determine the optimal DSAEK graft size based on pre-operative ASOCT measurements of the recipient eye. PMID:22824516

  6. VizieR Online Data Catalog: Faint ALMA 1.2mm sources down to ~0.02mJy (Fujimoto+, 2016)

    NASA Astrophysics Data System (ADS)

    Fujimoto, S.; Ouchi, M.; Ono, Y.; Shibuya, T.; Ishigaki, M.; Nagai, H.; Momose, R.

    2016-06-01

    We use 67 continuum maps obtained by ~120 pointing of the ALMA cycle 0-2 observations in Band 6/7 that accomplish high sensitivities and angular resolutions. For the mapping mode definitions, there are maps targeting field regions by single-pointing observations, referred to as "field" data, 4 and 62 out of which are taken from our programs and the ALMA archive, respectively. Two out of the four maps were taken in the ALMA cycle-0 Band 6 observations for the spectroscopically confirmed Lyα emitter (LAE) at z=6.595 (Himiko) and an LAE at z=6.511 (NB921-N-79144). See Ono et al. (2014ApJ...795....5O) for a summary of these observations. We also utilize two maps of newly obtained (ALMA cycle 2) field data of Bands 6 and 7 taken for spectroscopically confirmed LAEs at z=5.7 (NB816-S-61269) and at z=7.3 (NB101-S-2904). The NB816-S-61269 observations were carried out in the ALMA program of #2012.1.00602.S (PI: R. Momose) on 2014 May 20, Jun 19, and July 7 with 43 12m antennae array in the range of 18-650m baseline. The NB101-S-2904 data were taken in the ALMA program of #2012.1.00088.S (PI: M. Ouchi) on 2014 July 22 and August 6, 7, 14, and 18, with 55 12m antennae array in the extended configuration of 18-1300m baseline. See section 2.1 for further explanations. To increase the number of ALMA sources, we make full use of ALMA archival data of cycles 0 and 1 that became public by 2015 June. See references in table2 for the collected 62 maps and section 2.2.1 for further details. One-cluster data were taken for Abell 1689 (A1689) in ALMA cycle 0 and 1 observations (PI: J. Richard) of ALMA #2011.0.00319.S and #2012.1.00261.S (see section 2.2.2 for further explanations). (3 data files).

  7. Engineering Strong Interactions Between mm-wave and Optical Photons

    NASA Astrophysics Data System (ADS)

    Stone, Mark; Suleymanzade, Aziza; Estes, Jeremy; Eustice, Scott; Schuster, David; Simon, Jonathan

    2016-05-01

    We propose an atomic interface of Rydberg atoms as a means of engineering effective strong interactions between single mm-wave and optical photons. The atomic sample resides at the intersection of a high-finesse optical cavity and a superconducting mm-wave cavity, where it can coherently interact with photons of both regimes. The use of mm-wave (100 GHz) frequencies allows strong coupling at higher temperatures and with less sensitivity to stray electric fields. A hybrid cryogenic vacuum chamber at 4 Kelvin enables access to superconductivity as well as a UHV environment with optical access necessary for cold atom experiments. Strong interactions between these separate quantum degrees of freedom has important applications in quantum computing as well as simulation of many-body interacting systems.

  8. QM/MM X-ray Refinement of Zinc Metalloenzymes

    PubMed Central

    Li, Xue; Hayik, Seth A.; Merz, Kenneth M.

    2010-01-01

    Zinc metalloenzymes play an important role in biology. However, due to the limitation of molecular force field energy restraints used in X-ray refinement at medium or low resolutions, the precise geometry of the zinc coordination environment can be difficult to distinguish from ambiguous electron density maps. Due to the difficulties involved in defining accurate force fields for metal ions, the QM/MM (Quantum-Mechanical /Molecular-Mechanical) method provides an attractive and more general alternative for the study and refinement of metalloprotein active sites. Herein we present three examples that indicate that QM/MM based refinement yields a superior description of the crystal structure based on R and Rfree values and on the inspection of the zinc coordination environment. It is concluded that QM/MM refinement is a useful general tool for the improvement of the metal coordination sphere in metalloenzyme active sites. PMID:20116858

  9. Laparoscopic 5-mm Trocar Site Herniation and Literature Review

    PubMed Central

    Minikel, Laura; Zaritsky, Eve

    2011-01-01

    Objective: To evaluate the evidence for fascial closure of 5-mm laparoscopic trocar sites. Methods: We conducted electronic database searches of PubMed and the Cochrane Library for articles published between November 2008 and December 2010. We used the keywords trocar hernia, trocar-site hernia, laparoscopic hernia, trocar port-site hernia, laparoscopic port-site hernia. Prospective and retrospective case series, randomized trials, literature reviews, and randomized animal studies of trocar hernias on abdominal wall defects from gynecologic, urologic, and general surgery literature were reviewed. The Cochrane Database was reviewed for pertinent studies. Metaanalysis was not possible due to the significant heterogeneity between studies and lack of randomized trials large enough to assess the incidence of this rare complication. Results: Trocar-site hernias are a rare but known complication of laparoscopic surgery. Trocar size ≥10mm is associated with an increased rate of hernia development. Currently, the accepted gynecologic surgical practice is closure of fascial incisions ≥10mm, while incisions <10mm do not require closure. However, large prospective and retrospective case series reports from general surgery and urology literature support nonclosure of blunt or radially dilating trocars in paramedian sites. Expert opinion and small case reports suggest that in cases of prolonged manipulation of 5-mm trocar sites the surgeon should consider fascial closure, because extension of the initial incision may have occurred. Conclusion: There is no evidence to recommend routine closure of 5-mm trocar incisions; the choice should continue to be left to the discretion of the individual surgeon. PMID:21902958

  10. 450mm wafer patterning with jet and flash imprint lithography

    NASA Astrophysics Data System (ADS)

    Thompson, Ecron; Hellebrekers, Paul; Hofemann, Paul; LaBrake, Dwayne L.; Resnick, Douglas J.; Sreenivasan, S. V.

    2013-09-01

    The next step in the evolution of wafer size is 450mm. Any transition in sizing is an enormous task that must account for fabrication space, environmental health and safety concerns, wafer standards, metrology capability, individual process module development and device integration. For 450mm, an aggressive goal of 2018 has been set, with pilot line operation as early as 2016. To address these goals, consortiums have been formed to establish the infrastructure necessary to the transition, with a focus on the development of both process and metrology tools. Central to any process module development, which includes deposition, etch and chemical mechanical polishing is the lithography tool. In order to address the need for early learning and advance process module development, Molecular Imprints Inc. has provided the industry with the first advanced lithography platform, the Imprio® 450, capable of patterning a full 450mm wafer. The Imprio 450 was accepted by Intel at the end of 2012 and is now being used to support the 450mm wafer process development demands as part of a multi-year wafer services contract to facilitate the semiconductor industry's transition to lower cost 450mm wafer production. The Imprio 450 uses a Jet and Flash Imprint Lithography (J-FILTM) process that employs drop dispensing of UV curable resists to assist high resolution patterning for subsequent dry etch pattern transfer. The technology is actively being used to develop solutions for markets including NAND Flash memory, patterned media for hard disk drives and displays. This paper reviews the recent performance of the J-FIL technology (including overlay, throughput and defectivity), mask development improvements provided by Dai Nippon Printing, and the application of the technology to a 450mm lithography platform.

  11. Comparison of Failure Thickness and Critical Diameter of Nitromethane

    NASA Astrophysics Data System (ADS)

    Petel, Oren E.

    2005-07-01

    The critical diameter and failure thickness of liquid nitromethane confined by aluminum are determined experimentally. A comparison of these two parameters provides insight into the failure mechanism in nitromethane. If the failure of detonation in a critical charge diameter (or thickness) experiment is due to reaction quenching resulting from wave curvature, then it is expected that the critical diameter should be half the value of the critical thickness.[1] This has been shown to be the case with gas-phase detonations with nearly laminar reaction zones.[2] By comparing the experimentally determined values of critical diameter and thickness for a homogeneous liquid explosive, the validity of this model of detonation failure can be assessed. References: 1. Ramsay, J.B., 8th Symp. (Int.) on Detonation., 372-379 (1985). 2. Radulescu, M., Lee, J.H.S., Comb. and Flame, 131:29-46 (2002).

  12. SMALL DIAMETER STENCILING, ROLLING OVER STAMP. United States Pipe ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SMALL DIAMETER STENCILING, ROLLING OVER STAMP. - United States Pipe & Foundry Company Plant, Coating, Painting, Lining & Packaging Building, 2023 St. Louis Avenue at I-20/59, Bessemer, Jefferson County, AL

  13. Wavelength dependence of the apparent diameter of retinal blood vessels.

    PubMed

    Park, Robert; Twietmeyer, Karen; Chipman, Russell; Beaudry, Neil; Salyer, David

    2005-04-01

    Imaging of retinal blood vessels may assist in the diagnosis and monitoring of diseases such as glaucoma, diabetic retinopathy, and hypertension. However, close examination reveals that the contrast and apparent diameter of vessels are dependent on the wavelength of the illuminating light. In this study multispectral images of large arteries and veins within enucleated swine eyes are obtained with a modified fundus camera by use of intravitreal illumination. The diameters of selected vessels are measured as a function of wavelength by cross-sectional analysis. A fixed scale with spectrally independent dimension is placed above the retina to isolate the chromatic effects of the imaging system and eye. Significant apparent differences between arterial and venous diameters are found, with larger diameters observed at shorter wavelengths. These differences are due primarily to spectral absorption in the cylindrical blood column. PMID:15813519

  14. Optimal electrode diameter in relation to volume of the cochlea.

    PubMed

    Gnansia, D; Demarcy, T; Vandersteen, C; Raffaelli, C; Guevara, N; Delingette, H; Ayache, N

    2016-06-01

    The volume of the cochlea is a key parameter for electrode-array design. Indeed, it constrains the diameter of the electrode-array for low-traumatic positioning in the scala timpani. The present report shows a model of scala timpani volume extraction from temporal bones images in order to estimate a maximum diameter of an electrode-array. Nine temporal bones were used, and passed to high-resolution computed tomography scan. Using image-processing techniques, scala timpani were extracted from images, and cross-section areas were estimated along cochlear turns. Cochlear implant electrode-array was fitted in these cross-sections. Results show that the electrode-array diameter is small enough to fit in the scala timpani, however the diameter is restricted at the apical part. PMID:27246746

  15. Anomalous dependence of band gaps of binary nanotubes on diameters

    NASA Astrophysics Data System (ADS)

    Adhikari, Kapil; Huda, Muhammad; Ray, Asok

    2012-02-01

    Using cluster approximation, AlN, BN, GaN, SiGe, SiC, and GeC armchair type 1 nanotubes have been spin optimized using the hybrid functional B3LYP, a double ζ basis set and the GAUSSIAN 03 software. The electronic structures of group III nitride and group IV-IV nanotubes indicate that the band gap increases with tube diameter contrary to behavior expected from quantum size effects. A detailed study indicates that, in a class of binary nanotubes with partial ionic contributions in the bonds, for example, AlN, BN, GaN, GeC, and SiC, ionicity of the bonds decreases as diameter decreases due to increased sp^3 contribution. This causes the band gap to increase with diameter. But in nanotubes with covalent bonding, for example SiGe, the gap decreases with diameter. A general trend for a class of binary nanotubes is established.

  16. SMALL DIAMETER GRAVITY SEWERS: AN ALTERNATIVE FOR UNSEWERED COMMUNITIES

    EPA Science Inventory

    The most recently introduced wastewater collection alternative for small unsewered communities is septic tank effluent drains or small diameter gravity sewers (SDGS). Unlike conventional sewers, SDGS only collect settled wastewater. Grit, grease and other troublesome solids which...

  17. SMALL DIAMETER CEMENT LINING FROM STAIRWAY. United States Pipe ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SMALL DIAMETER CEMENT LINING FROM STAIRWAY. - United States Pipe & Foundry Company Plant, Coating, Painting, Lining & Packaging Building, 2023 St. Louis Avenue at I-20/59, Bessemer, Jefferson County, AL

  18. SMALL DIAMETER PRECEMENT LINING FROM CATWALK ABOVE. United States ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SMALL DIAMETER PRE-CEMENT LINING FROM CATWALK ABOVE. - United States Pipe & Foundry Company Plant, Coating, Painting, Lining & Packaging Building, 2023 St. Louis Avenue at I-20/59, Bessemer, Jefferson County, AL

  19. Northern view of inside diameter welding station of the saw ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Northern view of inside diameter welding station of the saw line in bay9 of the main pipe mill building. - U.S. Steel National Tube Works, Main Pipe Mill Building, Along Monongahela River, McKeesport, Allegheny County, PA

  20. SMALL DIAMETER PAINTING FROM CATWALK ABOVE. United States Pipe ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    SMALL DIAMETER PAINTING FROM CATWALK ABOVE. - United States Pipe & Foundry Company Plant, Coating, Painting, Lining & Packaging Building, 2023 St. Louis Avenue at I-20/59, Bessemer, Jefferson County, AL