  1. 1-3 piezoelectric composites for high temperature transducer applications

    PubMed Central

    Li, Lili; Zhang, Shujun; Xu, Zhuo; Wen, Fei; Geng, Xuecang; Lee, Hyeong Jae; Shrout, Thomas R.

    2013-01-01

    High temperature Pb(Zr,Ti)O3 /epoxy 1-3 composites were fabricated using the dice and fill method. The epoxy filler was modified with glass spheres in order to improve the thermal reliability of the composites at elevated temperatures. Temperature dependent dielectric and electromechanical properties of the composites were measured after aging at 250°C with different dwelling times. Obvious cracks were observed and the electrodes were damaged in the composite with unmodified epoxy after 200 hours, leading to the failure of the composite. In contrast, composites with >12 vol% glass sphere loaded epoxies were found to exhibit minimal electrical property variation after aging for 500 hours, with dielectric permittivity, piezoelectric coefficient and electromechanical coupling being on the order of 940, 310pC/N and 57%, respectively. This is due to the improved thermal expansion behavior of the modified filler. PMID:23729863

  2. Modeling and design of 1-3 tubular composite for smart transducer applications

    SciTech Connect

    Chen, J.; Zhang, Q.M.; Cross, L.E.; Trottier, M.

    1994-12-31

    A new type of 1-3 piezocomposite has been developed recently for advanced transducer applications. The composite made of piezoelectric ceramic tubes embedded in a polymer matrix has many unique features, such as tunability on acoustic impedance and piezoelectric response. The stress analysis indicates that the elastic parameters of polymer matrix have significant effects on the performance of 1-3 tubular piezocomposites. By optimizing the structure of composite and the elastic properties of the polymer matrix, the piezocomposite has a exceptionally large hydrostatic response, d{sub h}, and a very high receiving sensitivity. A low electric impedance and large effective piezoelectric constants suggest that the transducers in the form of the 1-3 tubular piezocomposites are superior to normal 1-3 rod piezocomposites in hydrostatic applications.

  3. Underwater characterizations of monolithic piezoceramic and 1-3 composite using a self-designed transducer

    NASA Astrophysics Data System (ADS)

    Saleem Mirza, Muhammad; Yasin, Tariq; Ikram, Masroor; Altaf, Muhammad; Mushtaq, Zahir; Nasir Khan, Muhammad

    2016-03-01

    Underwater characterizations of (Pb0.94Sr0.04)(Zr0.52Ti0.48)O3 (PZT) and PZT/araldite-F 1-3 composite were carried out through a self-designed transducer. Disc-shaped samples of bulk PZT and PZT/araldite-F composite were first characterized in air and then were assembled in the transducer individually. The transducer's underwater voltage receiving sensitivity (Sh) and transmitting voltage response (Sv) were investigated in the frequency range of 10-200 kHz (well below thickness mode resonance) using a calibrated projector and receiver method with pulse technique. Results revealed that the transducer made with composite sample exhibited better (Sh) values (-214 dB ref 1 V/µPa) due to ~295% higher piezoelectric voltage coefficient gh (30 × 10-3 Vm/N) of the composite compared to PZT. In addition, the transducer with the PZT sample showed better Sv values (80 dB ref 1 µPa/1 V at 1 m) due to the presence of planar mode peaks in the frequency range of 10-200 kHz. These results indicate that the monolithic piezoceramic can exhibit underwater Sv response in both planar and thickness resonance modes owing to the admittance peaks in these frequency regions.

  4. Design of low-loss 1-3 piezoelectric composites for high-power transducer applications.

    PubMed

    Lee, Hyeong Jae; Zhang, Shujun

    2012-09-01

    Lead zirconate titanate (PZT)/polymer 1-3 composites have improved electromechanical properties compared with monolithic counterparts, but possess a low mechanical quality factor, limiting their use in high-power transducer applications. The goal of this work was to improve the mechanical quality factor of 1-3 PZT/polymer composites by optimizing the polymer materials. Theoretical analysis and modeling were performed for optimum composite design and various polymers were prepared and characterized. 1-3 piezocomposites were constructed and their electromechanical properties were experimentally determined. The results demonstrated that the composites with high-thermal-conductivity polymers generally have degraded electromechanical properties with significantly decreased mechanical quality factors, whereas the composites filled with low-loss and low-moduli polymers were found to have higher mechanical quality factors with higher electromechanical coupling factors: Q(m) ~ 200 and k(t) ~ 0.68 for PZT4 composites; Q(m) ~ 400 and k(t) ~ 0.6 for PZT8 composites. The improved mechanical quality factor of 1-3 piezocomposites may offer improved performance and thermal stability of transducers under high-drive operation. PMID:23007769

  5. The design, fabrication, and measured acoustic performance of a 1-3 piezoelectric composite Navy calibration standard transducer.

    PubMed

    Benjamin, K C; Petrie, S

    2001-05-01

    The design, fabrication, and acoustic calibration of a new 1-3 piezoelectric composite-based U.S. Navy standard (USRD-F82) are presented. The F82 dual array/parametric mode projector may be used as a reciprocal linear transducer, or may be used to exploit the nonlinear properties of the water to produce highly directional acoustic beams (4 to 3 deg) at relatively low frequencies (5 to 50 kHz, respectively). As a result of its wide bandwidth, a broad range of primary as well as secondary frequencies of operation is possible. In the linear mode of operation the transducer provides two separate arrays to be addressed topside for either transmit or receive applications. The two circular apertures are centered on the acoustic axis and have active diameters of 22.8 cm (9 in.) and 5.1 cm (2 in.). The smaller array aperture could be used to obtain broader acoustic beams at relatively high frequencies. Due to the absence of air-filled pressure release components, the transducer will operate over most ocean pressures and temperatures. A general description of the 1-3 piezoelectric composite-based transducer configuration and measured performance is presented. PMID:11386551

  6. A High-Frequency Annular-Array Transducer Using an Interdigital Bonded 1-3 Composite

    PubMed Central

    Chabok, Hamid Reza; Cannata, Jonathan M.; Kim, Hyung Ham; Williams, Jay A.; Park, Jinhyoung; Shung, K. Kirk

    2011-01-01

    This paper reports the design, fabrication, and characterization of a 1–3 composite annular-array transducer. An interdigital bonded (IB) 1–3 composite was prepared using two IB operations on a fine-grain piezoelectric ceramic. The final composite had 19-μm-wide posts separated by 6-μm-wide polymer kerfs. A novel method to remove metal electrodes from polymer portions of the 1–3 composite was established to eliminate the need for patterning and aligning the electrode on the composite to the electrodes on a flexible circuit. Unloaded epoxy was used for both the matching and backing layers and a flexible circuit was used for interconnect. A prototype array was successfully fabricated and tested. The results were in reasonable agreement with those predicted by a circuit-analogous model. The average center frequency estimated from the measured pulse-echo responses of array elements was 33.5 MHz and the −6-dB fractional bandwidth was 57%. The average insertion loss recorded was 14.3 dB, and the maximum crosstalk between the nearest-neighbor elements was less than −37 dB. Images of a wire phantom and excised porcine eye were obtained to show the capabilities of the array for high-frequency ultrasound imaging. PMID:21244988

  7. Improving the thermal stability of 1-3 piezoelectric composite transducers.

    PubMed

    Parr, Agnes C S; O'Leary, Richard L; Hayward, Gordon

    2005-04-01

    The effect of temperature on the behavior of 1-3 piezoelectric composites manufactured using various polymeric materials was assessed experimentally through electrical impedance analysis and laser vibrometry. Device behavior varied with temperature irrespective of the polymer filler. Most significant changes in the piezoelectric composites were recorded around the glass transition temperature (Tg) of the polymer; movement to lower fundamental resonant frequencies and higher values of electrical impedance minima were observed at higher temperatures. Decoupling of the pillars from the polymer matrix was observed by laser vibrometry at high temperatures. The use of high Tg polymer extended the operational temperature range of a piezoelectric composite, and a high Tg polymer with improved thermal conductivity also proved beneficial. For all devices, at temperatures very close to room temperature, subtle changes in device performance, linked to polymer softening, were observed. Particulate filled materials have been investigated, and it is recognized that the high viscosities and low mechanical damping of such materials could be problematic for piezoelectric composite manufacture. The thermal solver of the PZFlex finite element code has been used to predict the temporal and spatial temperature response of a selection of the devices presented. The simulated and experimental data compare favorably. PMID:16060502

  8. Broadband and high sensitive time-of-flight diffraction ultrasonic transducers based on PMNT/epoxy 1-3 piezoelectric composite.

    PubMed

    Liu, Dongxu; Yue, Qingwen; Deng, Ji; Lin, Di; Li, Xiaobing; Di, Wenning; Wang, Xi'an; Zhao, Xiangyong; Luo, Haosu

    2015-01-01

    5-6 MHz PMNT/epoxy 1-3 composites were prepared by a modified dice-and-fill method. They exhibit excellent properties for ultrasonic transducer applications, such as ultrahigh thickness electromechanical coupling coefficient k(t) (85.7%), large piezoelectric coefficient d33 (1209 pC/N), and relatively low acoustic impedance Z (1.82 × 107 kg/(m2·s)). Besides, two types of Time-of-Flight Diffraction (TOFD) ultrasonic transducers have been designed, fabricated, and characterized, which have different matching layer schemes with the acoustic impedance of 4.8 and 5.7 × 106 kg/(m2·s), respectively. In the detection on a backwall of 12.7 mm polystyrene, the former exhibits higher detectivity, the relative pulse-echo sensitivity and -6 dB relative bandwidth are -21.93 dB and 102.7%, respectively, while the later exhibits broader bandwidth, the relative pulse-echo sensitivity and -6 dB relative bandwidth are -24.08 dB and 117.3%, respectively. These TOFD ultrasonic transducers based on PMNT/epoxy 1-3 composite exhibit considerably improved performance over the commercial PZT/epoxy 1-3 composite TOFD ultrasonic transducer. PMID:25808776

  9. Phantom evaluation of stacked-type dual-frequency 1-3 composite transducers: A feasibility study on intracavitary acoustic angiography.

    PubMed

    Kim, Jinwook; Li, Sibo; Kasoji, Sandeep; Dayton, Paul A; Jiang, Xiaoning

    2015-12-01

    In this paper, we present phantom evaluation results of a stacked-type dual-frequency 1-3 piezoelectric composite transducer as a feasibility study for intracavitary acoustic angiography. Our previous design (6.5/30 MHz PMN-PT single crystal transducer) for intravascular contrast ultrasound imaging exhibited a contrast-to-tissue ratio (CTR) of 12 dB with a penetration depth of 2.5 mm. For improved penetration depth (>3 mm) and comparable contrast-to-tissue ratio (>12 dB), we evaluated a lower frequency 2/14 MHz PZT 1-3 composite transducer. Superharmonic imaging performance of this transducer and a detailed characterization of key parameters for acoustic angiography are presented. The 2/14 MHz arrangement demonstrated a -6 dB fractional bandwidth of 56.5% for the transmitter and 41.8% for the receiver, and produced sufficient peak-negative pressures (>1.5 MPa) at 2 MHz to induce a strong nonlinear harmonic response from microbubble contrast agents. In an in-vitro contrast ultrasound study using a tissue mimicking phantom and 200 μm cellulose microvessels, higher harmonic microbubble responses, from the 5th through the 7th harmonics, were detected with a signal-to-noise ratio of 16 dB. The microvessels were resolved in a two-dimensional image with a -6dB axial resolution of 615 μm (5.5 times the wavelength of 14 MHz waves) and a contrast-to-tissue ratio of 16 dB. This feasibility study, including detailed explanation of phantom evaluation and characterization procedures for key parameters, will be useful for the development of future dual-frequency array transducers for intracavitary acoustic angiography. PMID:26112426

  10. Polymer film composite transducer

    DOEpatents

    Owen, Thomas E.

    2005-09-20

    A composite piezoelectric transducer, whose piezoeletric element is a "ribbon wound" film of piezolectric material. As the film is excited, it expands and contracts, which results in expansion and contraction of the diameter of the entire ribbon winding. This is accompanied by expansion and contraction of the thickness of the ribbon winding, such that the sound radiating plate may be placed on the side of the winding.

  11. Electroacoustic response of 1-3 piezocomposite transducers for high power applications.

    PubMed

    Jae Lee, Hyeong; Zhang, Shujun; Geng, Xuecang; Shrout, Thomas R

    2012-12-17

    The electroacoustic performance of 1-3 piezoelectric composite transducers with low loss polymer filler was studied and compared to monolithic Pb(Zr,Ti)O(3) (PZT) piezoelectric transducers. The 1-3 composite transducers exhibited significantly high electromechanical coupling factor (k(t) ∼ 0.64) when compared to monolithic counterparts (k(t) ∼ 0.5), leading to the improved bandwidth and loop sensitivity, being on the order of 67% and -24.0 dB versus 44% and -24.8 dB, respectively. In addition, the acoustic output power and transmit efficiency (∼50%) were found to be comparable to the monolithic PZT transducers, demonstrating potential for broad bandwidth, high power ultrasonic transducer applications. PMID:23319828

  12. Equivalent properties of 1-3 piezocomposites made of PMN-PT single crystals for underwater sonar transducers

    NASA Astrophysics Data System (ADS)

    Kim, Jinwook; Roh, Yongrae

    2011-04-01

    The design of a piezocomposite transducer is accomplished by such advanced modeling technique as finite element method (FEM). However, accurate analysis of a 1-3 piezocomposite transducer enforces three dimensional (3D) modeling that requires very finemeshing of the transducer structure, which is frequently over affordable calculation resource capacity. In order to simplify the FEM model for complicated underwater transducers, the 1-3 piezocomposite needs to be simulated with a single phase material of equivalent properties. The 1-3 piezocomposite material in this study is made of the PMN-PT single crystal as the active material and urethane as the matrix material. Theoretical models for the calculation of new material parameters of 1-3 composites having fine lateral periodicity have been derived. For the validation of the equivalent properties, TE (thickness extensional), LE (length extensional), LTE (length thickness extensional), and TS (thickness shear) FEM models have been built to compare the impedance-frequency spectra of the 1-3 composite material and an equivalent material. Through the simulation with the models, all the equivalent elastic, dielectric and piezoelectric constants of the single phase material are determined. Further, 3D and axis-symmetric 2D FEM models of a multi-mode Tonpilz transducer have been constructed with the equivalent material properties. The equivalent material provides a very good correlation between the 2D and 3D transducer models, which is not easily attainable with the full 1-3 piezocomposite model. This result confirms the efficacy of the equivalent material properties of the 1-3 piezocomposites.

  13. High Temperature, High Power Piezoelectric Composite Transducers

    PubMed Central

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, StewarT.

    2014-01-01

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined. PMID:25111242

  14. High temperature, high power piezoelectric composite transducers.

    PubMed

    Lee, Hyeong Jae; Zhang, Shujun; Bar-Cohen, Yoseph; Sherrit, Stewart

    2014-01-01

    Piezoelectric composites are a class of functional materials consisting of piezoelectric active materials and non-piezoelectric passive polymers, mechanically attached together to form different connectivities. These composites have several advantages compared to conventional piezoelectric ceramics and polymers, including improved electromechanical properties, mechanical flexibility and the ability to tailor properties by using several different connectivity patterns. These advantages have led to the improvement of overall transducer performance, such as transducer sensitivity and bandwidth, resulting in rapid implementation of piezoelectric composites in medical imaging ultrasounds and other acoustic transducers. Recently, new piezoelectric composite transducers have been developed with optimized composite components that have improved thermal stability and mechanical quality factors, making them promising candidates for high temperature, high power transducer applications, such as therapeutic ultrasound, high power ultrasonic wirebonding, high temperature non-destructive testing, and downhole energy harvesting. This paper will present recent developments of piezoelectric composite technology for high temperature and high power applications. The concerns and limitations of using piezoelectric composites will also be discussed, and the expected future research directions will be outlined. PMID:25111242

  15. Development of piezoelectric composites for transducers

    NASA Astrophysics Data System (ADS)

    Safari, A.

    1994-07-01

    For the past decade and a half, many different types of piezoelectric ceramic-polymer composites have been developed intended for transducer applications. These diphasic composites are prepared from non-active polymer, such as epoxy, and piezoelectric ceramic, such as PZT, in the form of filler powders, elongated fibers, multilayer and more complex three-dimensional structures. For the last four years, most of the efforts have been given to producing large area and fine scale PZT fiber composites. In this paper, processing of piezoelectric ceramic-polymer composites with various connectivity patterns are reviewed. Development of fine scale piezoelectric composites by lost mold, injection molding and the relic method are described. Research activities of different groups for preparing large area piezocomposites for hydrophone and actuator applications are briefly reviewed. Initial development of electrostrictive ceramics and composites are also

  16. Amperometric biosensors based on carbon composite transducers

    NASA Astrophysics Data System (ADS)

    Lu, Fang

    1998-12-01

    Much current work in analytical chemistry is devoted to design of biosensors. One particular area in this field is the development of enzyme-based amperometric biosensors for the quantitative determination of a series of substrates in clinical, environmental, industrial and agricultural significance. This dissertation focuses on the design of improved amperometric biosensors based on carbon composite transducers. The use of metallized carbons as transducer materials results in remarkably selective amperometric biosensors. Such enzyme-based transducers eliminate major electroactive interferences, and hence circumvent the need for mediators or membrane barriers. The remarkable selectivity of metal-dispersed carbons is attributed to their strong, preferential, electrocatalytic capacity towards the reductive detection of biologically-generated hydrogen peroxide. Such electrocatalytic activity allows metal-dispersed biosensors to be operated at the optimal potential region between +0.1 and -0.2 V, where the unwanted reactions are neglected resulting in the lowest noise level. Several new materials (e.g., ruthenium on carbon, rhodium on carbon, etc.) and constructions (e.g., carbon fiber, electrochemical co-deposition transducer, etc.) were applied in the development of novel enzyme-based transducers in order to improve the selectivity and applicability of amperometric biosensors. The susceptibility of first-generation oxidase amperometric biosensing to oxygen fluctuations can be improved by using oxygen-rich fluorocarbons as the pasting binders in carbon paste enzyme transducers. Such binders provide an internal supply of oxygen resulting in efficient detection in oxygen-deficit conditions. In particular, the use of poly-chlorotrifluorethylene (Kel-F) oil as carbon paste binder results in a well-defined response and an identical signal up to 40 mM glucose in both the presence and absence of oxygen. Comparing with mediated or wired enzyme-based transducers, such internal

  17. Analysis of multifrequency langevin composite ultrasonic transducers.

    PubMed

    Lin, Shuyu

    2009-09-01

    The multimode coupled vibration of Langevin composite ultrasonic transducers with conical metal mass of large cross-section is analyzed. The coupled resonance and anti-resonance frequency equations are derived and the effective electromechanical coupling coefficient is analyzed. The effect of the geometrical dimensions on the resonance frequency, the anti-resonance frequency, and the effective electromechanical coupling coefficient is studied. It is illustrated that when the radial dimension is large compared with the longitudinal dimension, the vibration of the Langevin transducer becomes a multifrequency multimode coupled vibration. Numerical methods are used to simulate the coupled vibration; the simulated results are in good agreement with those from the analytical results. Some Langevin transducers of large cross-section are designed and manufactured and their resonance frequencies are measured. It can be seen that the resonance frequencies obtained from the coupled resonance frequency equations are in good agreement with the measured results. It is expected that by properly choosing the dimensions, multifrequency Langevin transducers can be designed and used in ultrasonic cleaning, ultrasonic sonochemistry, and other applications. PMID:19812002

  18. Investigation into the effects of modification of the passive phase for improved manufacture of 1-3 connectivity piezocomposite transducers.

    PubMed

    O'Leary, R L; Hayward, G

    1999-01-01

    The 1-3 connectivity composite transducers comprise active piezoceramic pillars within a passive polymer matrix. The first stage in manufacturing the 1-3 material is to produce a bristle block (comprising a solid stock of active material with protruding pillars) by injection moulding or by dicing a piece of ceramic using precision sawing equipment. The bristle block is filled with a reactive polymer liquid that produces the passive polymer phase, and the filled block is machined to the desired dimensions. For optimum performance, the polymer phase should have complementary interaction with the ceramic phase as well as imparting dimensional stability. Epoxy-based polymers are the most usual passive materials because of their low viscosity in the uncured state and solvent resistance, coupled with their excellent adhesive, mechanical, and electrical properties. However, the curing of epoxy resins results in shrinkage of the polymer matrix and internal stress within the passive phase. This can lead to prestressing of the active ceramic material, distortion of pillars, reduction in the parallelism between the sides of pillars, acid, in certain circumstances, warpage of transducers. This is particularly evident when the solid stock in the bristle block is relatively thin. This paper reports the in situ modification of epoxy in the bristle block by UV-based low temperature polymerization of acrylate monomers within the epoxy matrix prior to polymerization of the epoxy resin. Internal stress measurements are presented to quantify the influence of this modification via a reduction of internal stress within the polymer matrix. Results from finite element analysis emphasise the conclusions of the experimental work, and examples of manufactured devices are presented. Composite transducer performance is assessed by laser measurement of surface displacement profiles, and a 50% improvement in surface displacement magnitude was observed for the modified devices. PMID:18238451

  19. Radially composite piezoelectric ceramic tubular transducer in radial vibration.

    PubMed

    Shuyu, Lin; Shuaijun, Wang

    2011-11-01

    The radially composite piezoelectric tubular transducer is studied. It is composed of radially poled piezoelectric and a long metal tube. The electro-mechanical equivalent circuit of the radially poled piezoelectric and metal tube in radial vibration is obtained. Based on the force and velocity boundary conditions, the six-port electro-mechanical equivalent circuit for the composite tubular transducer is given and the resonance/anti-resonance frequency equations are obtained. The relationship between the resonance frequency and the dimensions is analyzed. Numerically simulated results obtained by the finite element method are compared with those from the analytical method. Composite piezoelectric tubular transducers are designed and manufactured. The resonance/anti-resonance frequencies are measured, and it is shown that the theoretical results are in good agreement with the simulated and experimental results. It is expected that radially composite piezoelectric tubular transducers can be used as high-power ultrasonic radiators in ultrasonic applications, such as ultrasonic liquid processing. PMID:22083782

  20. Anodic aluminum oxide-epoxy composite acoustic matching layers for ultrasonic transducer application.

    PubMed

    Fang, H J; Chen, Y; Wong, C M; Qiu, W B; Chan, H L W; Dai, J Y; Li, Q; Yan, Q F

    2016-08-01

    The goal of this work is to demonstrate the application of anodic aluminum oxide (AAO) template as matching layer of ultrasonic transducer. Quarter-wavelength acoustic matching layer is known as a vital component in medical ultrasonic transducers to compensate the acoustic impedance mismatch between piezoelectric element and human body. The AAO matching layer is made of anodic aluminum oxide template filled with epoxy resin, i.e. AAO-epoxy 1-3 composite. Using this composite as the first matching layer, a ∼12MHz ultrasonic transducer based on soft lead zirconate titanate piezoelectric ceramic is fabricated, and pulse-echo measurements show that the transducer exhibits very good performance with broad bandwidth of 68% (-6dB) and two-way insertion loss of -22.7dB. Wire phantom ultrasonic image is also used to evaluate the transducer's performance, and the results confirm the process feasibility and merit of AAO-epoxy composite as a new matching material for ultrasonic transducer application. This matching scheme provides a solution to address the problems existing in the conventional 0-3 composite matching layer and suggests another useful application of AAO template. PMID:27125558

  1. Micromachined High Frequency PMN-PT/Epoxy 1-3 Composite Ultrasonic Annular Array

    PubMed Central

    Liu, Changgeng; Djuth, Frank; Li, Xiang; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk

    2013-01-01

    This paper reports the design, fabrication, and performance of miniature micromachined high frequency PMN-PT/epoxy 1-3 composite ultrasonic annular arrays. The PMN-PT single crystal 1-3 composites were made with micromachining techniques. The area of a single crystal pillar was 9 μm × 9 μm. The width of the kerf among pillars was ~ 5 μm and the kerfs were filled with a polymer. The composite thickness was 25 μm. A six-element annular transducer of equal element area of 0.2 mm2 with 16 μm kerf widths between annuli was produced. The aperture size the array transducer is about 1.5 mm in diameter. A novel electrical interconnection strategy for high density array elements was implemented. After the transducer was attached to the electric connection board and packaged, the array transducer was tested in a pulse/echo arrangement, whereby the center frequency, bandwidth, two-way insertion loss (IL), and cross talk between adjacent elements were measured for each annulus. The center frequency was 50 MHz and -6 dB bandwidth was 90%. The average insertion loss was 19.5 dB at 50 MHz and the crosstalk between adjacent elements was about -35 dB. The micromachining techniques described in this paper are promising for the fabrication of other types of high frequency transducers e.g. 1D and 2D arrays. PMID:22119324

  2. Micromachined PIN-PMN-PT crystal composite transducer for high-frequency intravascular ultrasound (IVUS) imaging.

    PubMed

    Li, Xiang; Ma, Teng; Tian, Jian; Han, Pengdi; Zhou, Qifa; Shung, K Kirk

    2014-07-01

    In this paper, we report the use of micromachined PbIn1/2Nb1/2O3-PbMg1/3Nb2/3O3-PbTiO 3 (PIN-PMNPT) single crystal 1-3 composite material for intravascular ultrasound (IVUS) imaging application. The effective electromechanical coupling coefficient kt(eff) of the composite was measured to be 0.75 to 0.78. Acoustic impedance was estimated to be 20 MRayl. Based on the composite, needle-type and flexible-type IVUS transducers were fabricated. The composite transducer achieved an 86% bandwidth at the center frequency of 41 MHz, which resulted in a 43 μm axial resolution. Ex vivo IVUS imaging was conducted to demonstrate the improvement of axial resolution. The composite transducer was capable of identifying the three layers of a cadaver coronary artery specimen with high resolution. The PIN-PMN-PT-based composite has superior piezoelectric properties comparable to PMN-PT-based composite and its thermal stability is higher than PMN-PT. PIN-PMN-PT crystal can be an alternative approach for fabricating high-frequency composite, instead of using PMN-PT. PMID:24960706

  3. Candle soot nanoparticles-polydimethylsiloxane composites for laser ultrasound transducers

    NASA Astrophysics Data System (ADS)

    Chang, Wei-Yi; Huang, Wenbin; Kim, Jinwook; Li, Sibo; Jiang, Xiaoning

    2015-10-01

    Generation of high power laser ultrasound strongly demands the advanced materials with efficient laser energy absorption, fast thermal diffusion, and large thermoelastic expansion capabilities. In this study, candle soot nanoparticles-polydimethylsiloxane (CSNPs-PDMS) composite was investigated as the functional layer for an optoacoustic transducer with high-energy conversion efficiency. The mean diameter of the collected candle soot carbon nanoparticles is about 45 nm, and the light absorption ratio at 532 nm wavelength is up to 96.24%. The prototyped CSNPs-PDMS nano-composite laser ultrasound transducer was characterized and compared with transducers using Cr-PDMS, carbon black (CB)-PDMS, and carbon nano-fiber (CNFs)-PDMS composites, respectively. Energy conversion coefficient and -6 dB frequency bandwidth of the CSNPs-PDMS composite laser ultrasound transducer were measured to be 4.41 × 10-3 and 21 MHz, respectively. The unprecedented laser ultrasound transduction performance using CSNPs-PDMS nano-composites is promising for a broad range of ultrasound therapy applications.

  4. Traveling Wave Ultrasonic Motor Using a Flexural Composite Transducer

    NASA Astrophysics Data System (ADS)

    Satonobu, Jun; Fukami, Masahiro; Nakagawa, Noritoshi

    2003-05-01

    This paper presents a new design for a traveling wave ultrasonic motor with a bolt-clamped Langevin transducer. A flexural composite transducer was attached to a ring around its circumference to excite two degenerate flexural vibration modes spatially and temporally orthogonal to each other in the ring for flexural traveling wave excitation. The prototype motor, composed of a 30-mm-diameter composite transducer attached along the outer edge of a 130-mm-diameter ring, was designed and tested. A maximum torque of 1.28 N\\cdotm with a maximum efficiency of 3.8% was achieved when driven at an applied voltage of approximately 200 Vrms and a preload of 172 N.

  5. Micromachined PIN-PMN-PT Crystal Composite Transducer for High-Frequency Intravascular Ultrasound (IVUS) Imaging

    PubMed Central

    Li, Xiang; Ma, Teng; Tian, Jian; Han, Pengdi; Zhou, Qifa; Shung, K. Kirk

    2015-01-01

    In this paper, we report the use of micromachined PbIn1/2Nb1/2O3–PbMg1/3Nb2/3O3–PbTiO3 (PIN-PMN-PT) single crystal 1–3 composite material for intravascular ultrasound (IVUS) imaging application. The effective electromechanical coupling coefficient kt(eff) of the composite was measured to be 0.75 to 0.78. Acoustic impedance was estimated to be 20 MRayl. Based on the composite, needle-type and flexible-type IVUS transducers were fabricated. The composite transducer achieved an 86% bandwidth at the center frequency of 41 MHz, which resulted in a 43 μm axial resolution. Ex vivo IVUS imaging was conducted to demonstrate the improvement of axial resolution. The composite transducer was capable of identifying the three layers of a cadaver coronary artery specimen with high resolution. The PIN-PMN-PT-based composite has superior piezoelectric properties comparable to PMN-PT-based composite and its thermal stability is higher than PMN-PT. PIN-PMN-PT crystal can be an alternative approach for fabricating high-frequency composite, instead of using PMN-PT. PMID:24960706

  6. Fiber optic ultrasound transducers with carbon/PDMS composite coatings

    NASA Astrophysics Data System (ADS)

    Mosse, Charles A.; Colchester, Richard J.; Bhachu, Davinder S.; Zhang, Edward Z.; Papakonstantinou, Ioannis; Desjardins, Adrien E.

    2014-03-01

    Novel ultrasound transducers were created with a composite of carbon nanotubes (CNTs) and polydimethylsiloxane (PDMS) that was dip coated onto the end faces of optical fibers. The CNTs were functionalized with oleylamine to allow for their dissolution in xylene, a solvent of PDMS. Ultrasound pulses were generated by illuminating the composite coating with pulsed laser light. At distances of 2 to 16 mm from the end faces, ultrasound pressures ranged from 0.81 to 0.07 MPa and from 0.27 to 0.03 MPa with 105 and 200 μm core fibers, respectively. Using an optical fiber hydrophone positioned adjacent to the coated 200 µm core optical fiber, ultrasound reflectance measurements were obtained from the outer surface of a sheep heart ventricle. The results of this study suggest that ultrasound transducers that comprise optical fibers with CNT-PDMS composite coatings may be suitable for miniature medical imaging probes.

  7. Evaluation of the Side Lobe Level Properties of 1-3 and 2-2 Piezocomposite Sonar Transducers with Printed Triangular Shape Electrodes in Comparison to a Convention Transducer Comprising of six PZT Bars with Analogue Network

    NASA Astrophysics Data System (ADS)

    Nicolaides, K.; Jideani, J.

    In a sonar line array the side lobes in the horizontal direction are controlled (reduced) using signal processing, while in the vertical direction are determined by the transducer design. Conventionally, this is done by using a transducer comprising discrete PZT bars spaced vertically and an analogue electronics network to apply different amplitudes to the bars. In this paper we present such a transducer comprising six PZT bars with its analogue network to produce a triangular shading (-24 dB main / side lobe level) and compare its performance to transducers made of 1-3 and 2-2 piezocomposite materials with printed triangular shape electrodes. All transducers were designed to operate between 400 kHz and 450 kHz. The measured receiving frequency response and polar directivity responses of the three transducers (including networks) will be presented and compared to the theoretical simulations. The results obtained showed significant improvement to the main lobe to side lobe ratio with both 1-3 and 2-2 piezoelectric based transducers. The transducers made with 1-3 piezocomposite material also achieved higher receiving response level. The fabrication of the 1-3 and 2-2 piezocomposite transducers with the printed electrodes also proved to be simpler and more cost effective.

  8. A vibration energy harvester using magnet/piezoelectric composite transducer

    NASA Astrophysics Data System (ADS)

    Qiu, Jing; Chen, Hengjia; Wen, Yumei; Li, Ping; Yang, Jin; Li, Wenli

    2014-05-01

    In this research, a vibration energy harvester employing the magnet/piezoelectric composite transducer to convert mechanical vibration energy into electrical energy is presented. The electric output performance of a vibration energy harvester has been investigated. Compared to traditional magnetoelectric transducer, the proposed vibration energy harvester has some remarkable characteristic which do not need binder. The experimental results show that the presented vibration energy harvester can obtain an average power of 0.39 mW for an acceleration of 0.6g at frequency of 38 Hz. Remarkably, this power is a very encouraging power figure that gives the prospect of being able to power a widely range of wireless sensors in wireless sensor network.

  9. Excitability of guided waves in composites with PWAS transducers

    NASA Astrophysics Data System (ADS)

    Shen, Yanfeng; Giurgiutiu, Victor

    2015-03-01

    Piezoelectric Wafer Active Sensors (PWAS) are convenient enablers for generating and receiving ultrasonic guided waves. The wide application of composite structures has put new challenges for the Structural Health Monitoring (SHM) and Nondestructive Evaluation (NDE) community due to the general anisotropic behaviors and complicated guided wave features in composites. The excitability of guided waves in composite structures directly influences the implementation of active sensing systems to achieve the best interrogation of certain sensing directions. This paper presents a hybrid modeling technique for studying the excitably of guided waves in composite structures with PWAS transducers. This hybrid technique comprehensively covers local finite element model (FEM), semi-analytical finite element (SAFE) method, and analytical guided wave solutions. Harmonic analysis of a small-size local FEM with non-reflective boundaries (NRB) was carried out for obtaining guided wave generation features in plate structures. The PWAS transducers were modeled with coupled filed elements. Thus, the FEM can fully capture the geometry and material property effects of PWAS transducers and their influence on the guided wave excitation. SAFE method was used to obtain the complicated guided wave features in composites such as dispersion curves and modeshapes. The SAFE procedure was coded into MATLAB Graphical User Interface (GUI), and the software SAFE-DISPERSION was developed. To study the excitability of each wave mode, we considered all the possible wave modes being generated simultaneously and propagating independently. The analytical wave expressions based on the exact guided wave solution with Hankel functions were used to join the SAFE method and the local FEM. Formulated in frequency domain, the hybrid model is highly efficient, providing an over determined equation system for the calculation of mode participation factors. Case studies were carried out: (1) the Lamb wave excitability

  10. Analysis and Development of Piezoelectric Composites for Medical Ultrasound Transducer Applications

    NASA Astrophysics Data System (ADS)

    Oakley, Clyde Gerald

    Over the past several years 1-3 piezoelectric composites have become increasingly important in medical ultrasound transducer applications. A substantial body of literature has been written regarding construction techniques, predicted and measured performance, and applications. Still, several important issues remain to be answered which are of importance to transducer designers. This thesis deals with several of those issues and presents new conceptual and computational tools specifically related to the design of piezoelectric composites for transducers used in medical imaging. The important topic of the symmetry of stopband edge resonance modes is investigated by use of an exact one-dimensional solution for infinite 2-2 composites. A simple conceptual model relating the stopband structure to the resonance of the individual components is presented and a computationally simple and accurate means of calculating stopband edge resonance frequencies is developed. The techniques are used to investigate the behavior of some composites with double periodicities. Effective medium theories are reviewed and calculations are compared to experimental results. A matrix version of the theory is used to calculate the slowness diagrams for a 1-3 composite and to investigate the design trade -offs which must be made in optimizing composite performance. A novel composite is proposed which consists of free-standing piezoelectric posts surrounded on the sides by air and bounded on front and back by stiff layers. Potential performance improvements and problems are presented. Experimental results showing excellent bandwidth and pulse length but only moderate sensitivity are given along with a proposed explanation for the results. Proposals for further work are suggested.

  11. Micromachining techniques in developing high-frequency piezoelectric composite ultrasonic array transducers.

    PubMed

    Liu, Changgeng; Djuth, Frank T; Zhou, Qifa; Shung, K Kirk

    2013-12-01

    Several micromachining techniques for the fabrication of high-frequency piezoelectric composite ultrasonic array transducers are described in this paper. A variety of different techniques are used in patterning the active piezoelectric material, attaching backing material to the transducer, and assembling an electronic interconnection board for transmission and reception from the array. To establish the feasibility of the process flow, a hybrid test ultrasound array transducer consisting of a 2-D array having an 8 × 8 element pattern and a 5-element annular array was designed, fabricated, and assessed. The arrays are designed for a center frequency of ~60 MHz. The 2-D array elements are 105 × 105 μm in size with 5-μm kerfs between elements. The annular array surrounds the square 2-D array and provides the option of transmitting from the annular array and receiving with the 2-D array. Each annular array element has an area of 0.71 mm(2) with a 16-μm kerf between elements. The active piezoelectric material is (1 - x) Pb(Mg1/3Nb2/3)O3-xPbTiO3 (PMN-PT)/epoxy 1-3 composite with a PMN-PT pillar lateral dimension of 8 μm and an average gap width of ~4 μm, which was produced by deep reactive ion etching (DRIE) dry etching techniques. A novel electric interconnection strategy for high-density, small-size array elements was proposed. After assembly, the array transducer was tested and characterized. The capacitance, pulse-echo responses, and crosstalk were measured for each array element. The desired center frequency of ~60 MHz was achieved and the -6-dB bandwidth of the received signal was ~50%. At the center frequency, the crosstalk between adjacent 2-D array elements was about -33 dB. The techniques described herein can be used to build larger arrays containing smaller elements. PMID:24297027

  12. Single crystal PZN/PT-polymer composites for ultrasound transducer applications.

    PubMed

    Ritter, T; Geng, X; Kirk Shung, K; Lopath, P D; Park, S E; Shrout, T R

    2000-01-01

    Single crystal relaxor ferroelectrics of PZN-8%PT were investigated for potential application in ultrasound transducers. The full set of electromechanical properties was determined using combined resonance and laser interferometry techniques. Ultra-high length extensional coupling (k(33)) of 0.94 was observed, a 25% increase over Navy Type VI PZT ceramics. The thickness extensional coupling (k(t)) of 0.48 was comparable to PZT compositions, and the compliance S(33)(E) was a factor of six greater. To maximize height extensional coupling (k'(33)), while minimizing length extensional coupling k(31) in array elements, it was necessary to align the elements along the 100 crystallographic direction in the x-y plane. Mode coupling plots and test samples for array elements determined that width-to-height ratios of less than 0.5 were desired, similar to the requirement for polycrystalline PZT ceramics. Modeling of 1-3 composites and experimental results demonstrated that thickness coupling greater than 0.80 could be achieved with a 40% to 70% volume fraction of PZN-PT. Although this is a substantial increase over PZT 1-3 composites, with a thickness coupling coefficient of 0.66, it represents a smaller fraction of the length extensional coupling k(33). This reduction may be a consequence of the increased compliance of PZN-PT, which results in significant clamping by the polymer matrix. Ultrasonic transducers fabricated using PZN-8%PT 1-3 composites achieved experimental bandwidths as high as 141%. The pulse-echo responses displayed good agreement with modeled results using the Redwood equivalent circuit. PMID:18238611

  13. Study on the Langevin piezoelectric ceramic ultrasonic transducer of longitudinal-flexural composite vibrational mode.

    PubMed

    Lin, Shuyu

    2006-01-01

    In this paper, the Langevin longitudinal-flexural composite mode piezoelectric ultrasonic transducer is studied. This type of transducers consists of slender metal rods and longitudinally polarized piezoelectric ceramic rings. The resonance frequency equations for the longitudinal and flexural vibrations in the transducer are derived. By correcting the length of the metal slender rods, the simultaneous resonance of the longitudinal and flexural vibrations in the transducer is acquired. The experimental results show that the measured resonance frequencies of the transducers are in good agreement with the computed ones, and the measured resonance frequencies of the longitudinal and the flexural vibrations in the composite transducers are also in good agreement with each other. PMID:16289195

  14. Bio-applications of ionic polymer metal composite transducers

    NASA Astrophysics Data System (ADS)

    Aw, K. C.; McDaid, A. J.

    2014-07-01

    Traditional robotic actuators have advanced performance which in some aspects can surpass that of humans, however they are lacking when it comes to developing devices which are capable of operating together with humans. Bio-inspired transducers, for example ionic polymer metal composites (IPMC), which have similar properties to human tissue and muscle, demonstrate much future promise as candidates for replacing traditional robotic actuators in medical robotics applications. This paper outlines four biomedical robotics applications, an IPMC stepper motor, an assistive glove exoskeleton/prosthetic hand, a surgical robotic tool and a micromanipulation system. These applications have been developed using mechanical design/modelling techniques with IPMC ‘artificial muscle’ as the actuation system. The systems are designed by first simulating the performance using an IPMC model and dynamic models of the mechanical system; the appropriate advanced adaptive control schemes are then implemented to ensure that the IPMCs operate in the correct manner, robustly over time. This paper serves as an overview of the applications and concludes with some discussion on the future challenges of developing real-world IPMC applications.

  15. Micromachining Techniques in Developing High-Frequency Piezoelectric Composite Ultrasonic Array Transducers

    PubMed Central

    Liu, Changgeng; Djuth, Frank T.; Zhou, Qifa; Shung, K. Kirk

    2014-01-01

    Several micromachining techniques for the fabrication of high-frequency piezoelectric composite ultrasonic array transducers are described in this paper. A variety of different techniques are used in patterning the active piezoelectric material, attaching backing material to the transducer, and assembling an electronic interconnection board for transmission and reception from the array. To establish the feasibility of the process flow, a hybrid test ultrasound array transducer consisting of a 2-D array having an 8 × 8 element pattern and a 5-element annular array was designed, fabricated, and assessed. The arrays are designed for a center frequency of ~60 MHz. The 2-D array elements are 105 × 105 μm in size with 5-μm kerfs between elements. The annular array surrounds the square 2-D array and provides the option of transmitting from the annular array and receiving with the 2-D array. Each annular array element has an area of 0.71 mm2 with a 16-μm kerf between elements. The active piezoelectric material is (1 − x) Pb(Mg1/3Nb2/3)O3−xPbTiO3 (PMN-PT)/epoxy 1–3 composite with a PMN-PT pillar lateral dimension of 8 μm and an average gap width of ~4 μm, which was produced by deep reactive ion etching (DRIE) dry etching techniques. A novel electric interconnection strategy for high-density, small-size array elements was proposed. After assembly, the array transducer was tested and characterized. The capacitance, pulse–echo responses, and crosstalk were measured for each array element. The desired center frequency of ~60 MHz was achieved and the −6-dB bandwidth of the received signal was ~50%. At the center frequency, the crosstalk between adjacent 2-D array elements was about −33 dB. The techniques described herein can be used to build larger arrays containing smaller elements. PMID:24297027

  16. Detection of acoustic emission from composite laminates using PVF2 transducers

    NASA Technical Reports Server (NTRS)

    Stiffler, R.; Henneke, E. G., II; Herakovich, C. T.

    1983-01-01

    Polyvinylidene fluoride (PVF2), a semicrystalline polymer exhibiting piezoelectricity, is presently used as a sensing transducer in acoustic emission (AE) monitoring of several different composite laminate materials in order to obtain both quasi-static and fatigue loading results. AE signals obtained from PVF2 transducers are compared with those obtained by standard AE sensors. It is noted that PVF2 transducers may, through the application of spectral signal analysis, be able to distinguish between two distinct failure modes which have been observed in two composite laminates of the same material, but employing different lamina stacking sequences.

  17. Adhesive defect detection in composite adhesive joints using phased array transducers

    NASA Astrophysics Data System (ADS)

    Ren, Baiyang; Lissenden, Cliff J.

    2015-03-01

    Composite materials are widely used in aircraft structures due to their high specific stiffness and strength. The laminated nature of composite structures makes them subject to disbond and delamination. These types of defects will compromise the integrity of the structure and therefore need to be monitored. To monitor aircraft structures, light weight transducers capable of large area coverage are beneficial. Ultrasonic guided waves are able to travel long distance and are sensitive to localized defects. The multi-modal characteristic of propagating guided waves requires optimal mode selection and excitation. Phased array transducers provide good versatility for optimal mode excitation since they can excite different guided wave modes preferentially. Phased array transducers designed for structural health monitoring (SHM) applications are employed in this work to study the interaction between adhesive defects and guided wave modes. Amplitude ratios and wave packet composition are utilized as defect indicators that are uniquely available due to the phased array transducers.

  18. Frequency wavenumber design of spiral macro fiber composite directional transducers

    NASA Astrophysics Data System (ADS)

    Carrara, Matteo; Ruzzene, Massimo

    2015-04-01

    This work is focused on design and testing of a novel class of transducers for Structural Health Monitoring (SHM), able to perform directional interrogation of plate-like structures. These transducers leverage guided waves (GWs), and in particular Lamb waves, that have emerged as a very prominent option for assessing the state of a structure during operation. GW-SHM approaches greatly benefit from the use of transducers with controllable directional characteristics, so that selective scanning of a surface can be performed to locate damage, impacts, or cracks. In the concepts that we propose, continuous beam steering and directional actuation are achieved through proper selection of the excitation frequency. The design procedure takes advantage of the wavenumber representation of the device, and formulates the problem using a Fourier-based approach. The active layer of the transducer is made of piezoelectric fibers embedded into an epoxy matrix, allowing the device to be flexible, and thus suitable for application on non{ at surfaces. Proper shaping of the electrodes pattern through a compensation function allows taking into account the anisotropy level introduced by the active layer. The resulting spiral frequency steerable acoustic actuator is a configuration that features (i) enhanced performance, (ii) reduced complexity, and (iii) reduced hardware requirements of such devices.

  19. Dynamic characteristics of an axially polarized multilayer piezoelectric/elastic composite cylindrical transducer.

    PubMed

    Wang, Jianjun; Shi, Zhifei

    2013-10-01

    An analytical model of the dynamic characteristics of an axially polarized multilayer piezoelectric/elastic composite cylindrical transducer is proposed in this paper. Based on the plane stress assumption, the dynamic analytical solution of the transducer under an external harmonic voltage load is obtained, and the electric admittance is also derived analytically. Inherent properties of the transducer, such as resonance and anti-resonance frequencies, are presented and discussed. In addition, comparisons with other related investigations are also given, and good agreement is found. The present investigation is very helpful for the design of axially polarized multilayer piezoelectric/elastic composite cylindrical transducers, which can be used in applications related to ultrasonic and underwater sound waves. PMID:24081268

  20. Piezoelectric transducer embedded in a composite plate: Application to Lamb wave generation

    SciTech Connect

    Moulin, E.; Assaad, J.; Delebarre, C.; Kaczmarek, H.; Balageas, D.

    1997-09-01

    The aim of this paper is to show that Lamb waves may be effectively generated using piezoelectric transducers embedded inside a composite plate, for nondestructive evaluation and health monitoring applications. A cylindrical transducer embedded in a composite host plate is considered. The electrical impedance of the transducer alone in vacuum and then of the embedded transducer, which allows the identification of the resonance modes, have been obtained by the finite element method (FEM). Moreover, the displacement fields in the plate, which allow the identification of the types of Lamb waves, have been computed at the resonance frequencies. Comparison between the FEM results and the Lamb wave dispersion curves of the host material are in good agreement. Experimental results (electrical impedance, frequency response, and phase velocities) concerning a composite plate specimen containing the same piezoelectric transducer inside it are shown. A good agreement is generally obtained between numerical and experimental results. In addition, it has been shown that the radial mode of the embedded transducer, which has a high coupling coefficient (around 50{percent}), can be used to generate S{sub 0} Lamb waves. {copyright} {ital 1997 American Institute of Physics.}

  1. Assessment of PZT transducer bonding techniques under drop-weight impact loading in composites

    NASA Astrophysics Data System (ADS)

    Mulligan, Kyle R.; Ostiguy, Pierre-Claude; Masson, Patrice; Elkoun, Saïd; Quaegebeur, Nicolas

    2011-04-01

    This paper describes the robustness of a structural health monitoring system (SHM) that utilizes lead-zirconatetitanate (PZT) transducers tested on carbon fibre composite coupons under drop-weight impact loading. Four PZT transducers are attached to the surface of 10.16 cm x 15.24 cm aerospace grade carbon fibre coupons using four types of adhesives: cyanoacrylate, epoxy, methyl methacrylate, and silicon. Each PZT transducer is tuned to excite preferentially an A0 mode guided wave burst into each composite coupon prior to and following an impact. The output from a PZT transducer, the amplitude of the propagating guided waves measured using a laser vibrometer on the coupon surface and the RMS velocity is plotted. The cycle is repeated for the three remaining transducers. The electrical admittance is also measured using an impedance analyzer prior to and following impact. This paper illustrates how a robustness metric expressed in terms of admittance can be used to infer the ability of the SHM system to generate guided waves and to detect damage following impact. The robustness metric is a measure of the adhesive strength and the mechanism to provide accurate damage detection results. It is shown that transducers attached using silicon provide accurate damage detection results based on pre-attached adhesive yielding difference of <0.5% obtained from electrical admittance measurements before and after impact.

  2. Fabrication and Performance of Endoscopic Ultrasound Radial Arrays Based on PMN-PT Single Crystal/Epoxy 1-3 Composite

    PubMed Central

    Zhou, Dan; Cheung, Kwok Fung; Chen, Yan; Lau, Sien Ting; Zhou, Qifa; Shung, K. Kirk; Luo, Hao Su; Dai, Jiyan; Chan, Helen Lai Wa

    2011-01-01

    In this paper, 0.7Pb(Mg1/3Nb2/3)O3-0.3PbTiO3 (PMN-PT) single crystal/epoxy 1–3 composite was used as the active material of the endoscopic ultrasonic radial array transducer, because this composite exhibited ultrahigh electromechanical coupling coefficient (kt = 0.81%), very low mechanical quality factor (Qm = 11) and relatively low acoustic impedance (Zt = 12 MRayls). A 6.91 MHz PMN-PT/epoxy 1–3 composite radial array transducer with 64 elements was tested in a pulse-echo response measurement. The −6-dB bandwidth of the composite array transducer was 102%, which was ~30% larger than that of traditional lead zirconate titanate array transducer. The two-way insertion loss was found to be −32.3 dB. The obtained results show that this broadband array transducer is promising for acquiring high-resolution endoscopic ultrasonic images in many clinical applications. PMID:21342833

  3. Lead-free BNT composite film for high-frequency broadband ultrasonic transducer applications.

    PubMed

    Yan, Xingwei; Ji, Hongfen; Lam, Kwok Ho; Chen, Ruimin; Zheng, Fan; Ren, Wei; Zhou, Qifa; Shung, K Kirk

    2013-07-01

    A lead-free Bi0.5Na0.5TiO3 (BNT) piezoelectric composite thick film with a thickness of ~11 μm has been fabricated using a modified sol-gel method. Dielectric constant, remnant polarization, and coercive field of the BNT composite film were found to be 1018, 22.6 μC/cm2, and 76.1 kV/cm, respectively. The film was used to fabricate a high-frequency needle transducer and the performance of the transducer was measured. The transducer without a matching layer exhibits a center frequency of 98 MHz and a -6-dB bandwidth of 86%. A wire phantom image acquired using the transducer shows an axial resolution of 15 ¿m and lateral resolution of 68 μm, respectively. Results from this study suggest that the BNT composite film is a promising lead-free piezoelectric material for high-frequency broadband ultrasonic transducer applications. PMID:25004521

  4. Design and fabrication of a low-frequency (1-3 MHz) ultrasound transducer for accurate placement of screw implants in the spine

    NASA Astrophysics Data System (ADS)

    Manbachi, Amir; Lee, Mike; Foster, F. Stuart; Ginsberg, Howard J.; Cobbold, Richard S. C.

    2014-03-01

    In 2012 approximately 800,000 spinal fusion surgeries were performed in the United States, requiring the insertion of screws into the pedicles. Their exact placement is critical and made complex due to limited visibility of the spine, continuous bleeding in the exposed regions, and variability in morphologies. The alarmingly high rate of screw misplacements (up to 20%) reported in the literature is of major concern since such misplacements can place the surrounding vital structures at risk. A potential guidance method for determining the best screw trajectory is by the use of real-time ultrasound imaging similar to that used for intravascular imaging. An endovascular transducer could be inserted into the pedicle to image the anatomy from within and identify bone boundaries. A major challenge of imaging within bone is high signal attenuation. The rapid increase of attenuation with frequency requires much lower frequencies (1-3 MHz) than those used in intravascular imaging. This study describes the custom design and fabrication of 2 MHz ultrasound probes (3.5 mm diameter/ 11 Fr) for pedicle screw guidance. Three transducer designs are explored to provide improved sensitivity and signal to noise ratio, compared to the previously tested transducer within the pedicle. Experimental measurements are compared with the results obtained using various simulation tools. The work reported in this paper represents the first stage in our ultimate goal of developing a 32- element phased array that is capable of generating a radial B-mode image.

  5. Ultrasonic guided wave monitoring of composite bonded joints using macro fiber composite transducers

    NASA Astrophysics Data System (ADS)

    Matt, Howard; Bartoli, Ivan; Coccia, Stefano; Lanza di Scalea, Francesco; Oliver, Joseph; Kosmatka, John; Park, Gyuhae; Farrar, Charles

    2006-03-01

    The monitoring of adhesively-bonded joints through the use of ultrasonic guided waves is the general topic of this paper. Specifically, composite-to-composite joints representative of the wing skin-to-spar bonds of Unmanned Aerial Vehicles (UAVs) are examined. This research is the first step towards the development of an on-board structural health monitoring system for UAV wings based on integrated ultrasonic sensors. The study investigates two different lay-ups for the wing skin and two different types of bond defects, namely poorly-cured adhesive and disbonded interfaces. The guided wave propagation problem is studied numerically by a semi-analytical finite element method that accounts for viscoelastic damping, and experimentally by utilizing macro fiber composite (MFC) transducers which are inexpensive, flexible, highly robust, and viable candidates for application in on-board monitoring systems. Based upon change in energy transmission, the presence of damage is successfully identified through features extracted in both the time domain and discrete wavelet transform domain. A unique "passive" version of the diagnostic system is also demonstrated experimentally, whereby MFC sensors are utilized for detecting and locating simulated active damage in an aluminum plate. By exploiting the directivity behavior of MFC sensors, a damage location algorithm which is independent of wave speed is developed. Application of this approach in CFRP components may alleviate difficulties associated with damage location in highly anisotropic systems.

  6. Monitoring of composite structures using a network of integrated PVDF film transducers

    NASA Astrophysics Data System (ADS)

    Guzmán, Enrique; Cugnoni, Joël; Gmür, Thomas

    2015-05-01

    Aiming to reduce costs, polyvinylidene difluoride (PVDF) film patches are an emerging alternative to more classic piezoelectric technologies, like ceramic patches, as transducers to measure local deformation in many structural applications. This choice is supported by advantages such as the low weight and mechanical flexibility of PVDF, making this polymer suitable for embedding inside full scale polymer based composite structures. Piezoelectric transducer patches can be used as actuators to dynamically excite full-scale composite structures, and as sensors to measure the strain. The main objective of this paper is to verify that the PVDF transducers can provide exploitable signals in the context of structural health monitoring. In order to do so, two aspects of the design of transducer network are investigated: the optimization of the sensor network, for which the effective independence method is proposed, and the use of operational modal analysis (OMA), since it is a simple method to extract the natural frequencies of a structure from a time series. The results of the analysis are compared to a reference set issued from experimental modal analysis (EMA), a simple, well-known, classic method, which is carried out using accelerometers and an impact hammer. By statistical means, it is shown that there is no significant difference between the two methods, and an optimized PVDF transducer network combined with OMA can perform the dynamic analysis of a structure as well as a classic EMA setup would do. This leads the way to the use of low-cost PVDF embedded transducer networks for robust composite material characterization.

  7. KNN/BNT Composite Lead-Free Films for High-Frequency Ultrasonic Transducer Applications

    PubMed Central

    Lau, Sien Ting; Ji, Hong Fen; Li, Xiang; Ren, Wei; Zhou, Qifa; Shung, K. Kirk

    2011-01-01

    Lead-free K0.5Na0.5NbO3/Bi0.5Na0.5TiO3 (KNN/BNT) films have been fabricated by a composite sol-gel technique. Crystalline KNN fine powder was dispersed in the BNT precursor solution to form a composite slurry which was then spin-coated onto a platinum-buffered Si substrate. Repeated layering and vacuum infiltration were applied to produce 5-μm-thick dense composite film. By optimizing the sintering temperature, the films exhibited good dielectric and ferroelectric properties comparable to PZT films. A 193-MHz high-frequency ultrasonic transducer fabricated from this composite film showed a −6-dB bandwidth of approximately 34%. A tungsten wire phantom was imaged to demonstrate the capability of the transducer. PMID:21244994

  8. KNN/BNT composite lead-free films for high-frequency ultrasonic transducer applications.

    PubMed

    Lau, Sien Ting; Ji, Hong Fen; Li, Xiang; Ren, Wei; Zhou, Qifa; Shung, K Kirk

    2011-01-01

    Lead-free K(0.5)Na(0.5)NbO(3)/Bi(0.5)Na(0.5)TiO(3) (KNN/ BNT) films have been fabricated by a composite sol-gel technique. Crystalline KNN fine powder was dispersed in the BNT precursor solution to form a composite slurry which was then spin-coated onto a platinum-buffered Si substrate. Repeated layering and vacuum infiltration were applied to produce 5-μm-thick dense composite film. By optimizing the sintering temperature, the films exhibited good dielectric and ferroelectric properties comparable to PZT films. A 193-MHz high-frequency ultrasonic transducer fabricated from this composite film showed a -6-dB bandwidth of approximately 34%. A tungsten wire phantom was imaged to demonstrate the capability of the transducer. PMID:21244994

  9. Magnetoelectric Composites for 1.3 GHz Antennas

    NASA Astrophysics Data System (ADS)

    Petrov, R. V.; Tatarenko, A. S.; Srinivasan, G.; Bichurin, M. I.

    2008-03-01

    A microstrip miniaturized antenna based on magnetoelectric composite has been designed and characterized. Theoretical estimates of antenna properties are given. To miniaturize UHF antennas, one needs slow-wave topologies and magneto-electric (ME) materials with equal and high permeability and permittivity. Nickel Zinc Ferrites (Ni1-xZnxFe2O4, x=0-0.5, NZFO) are potential candidates for use as the magnetic phase in the composite since they have high permeability, in the range 4-50, and low magnetic loss tangent. The dielectric phase use is bismuth strontium titanates (Sr1-1.5xBixTiO3, 0.04composite substrate with dimensions 65 x 40 x 2.2 mm^3. The other side of the substrate has a metal ground plane. Measurements of transfer scattering parameter S21 are made. A miniaturization factor of 5-10 is achieved. The miniaturization methodology discussed here is useful for mobile communication platforms, radar systems, and remote-controlled ground based systems.

  10. Smart damping of laminated fuzzy fiber reinforced composite shells using 1-3 piezoelectric composites

    NASA Astrophysics Data System (ADS)

    Kundalwal, S. I.; Kumar, R. Suresh; Ray, M. C.

    2013-10-01

    This paper deals with the investigation of active constrained layer damping (ACLD) of smart laminated continuous fuzzy fiber reinforced composite (FFRC) shells. The distinct constructional feature of a novel FFRC is that the uniformly spaced short carbon nanotubes (CNTs) are radially grown on the circumferential surfaces of the continuous carbon fiber reinforcements. The constraining layer of the ACLD treatment is considered to be made of vertically/obliquely reinforced 1-3 piezoelectric composite materials. A finite element (FE) model is developed for the laminated FFRC shells integrated with the two patches of the ACLD treatment to investigate the damping characteristics of the laminated FFRC shells. The effect of variation of the orientation angle of the piezoelectric fibers on the damping characteristics of the laminated FFRC shells has been studied when the piezoelectric fibers are coplanar with either of the two mutually orthogonal vertical planes of the piezoelectric composite layer. It is revealed that radial growth of CNTs on the circumferential surfaces of the carbon fibers enhances the attenuation of the amplitude of vibrations and the natural frequencies of the laminated FFRC shells over those of laminated base composite shells without CNTs.

  11. Design of Low-Loss 1–3 Piezoelectric Composites for High-Power Transducer Applications

    PubMed Central

    Lee, Hyeong Jae; Zhang, Shujun

    2013-01-01

    Lead zirconate titanate (PZT)/polymer 1–3 composites have improved electromechanical properties compared with monolithic counterparts, but possess a low mechanical quality factor, limiting their use in high-power transducer applications. The goal of this work was to improve the mechanical quality factor of 1–3 PZT/polymer composites by optimizing the polymer materials. Theoretical analysis and modeling were performed for optimum composite design and various polymers were prepared and characterized. 1–3 piezocomposites were constructed and their electromechanical properties were experimentally determined. The results demonstrated that the composites with high-thermal-conductivity polymers generally have degraded electromechanical properties with significantly decreased mechanical quality factors, whereas the composites filled with low-loss and low-moduli polymers were found to have higher mechanical quality factors with higher electrome-chanical coupling factors: Qm ~ 200 and kt ~ 0.68 for PZT4 composites; Qm ~ 400 and kt ~ 0.6 for PZT8 composites. The improved mechanical quality factor of 1–3 piezocomposites may offer improved performance and thermal stability of transducers under high-drive operation. PMID:23007769

  12. Process and Structural Health Monitoring of Composite Structures with Embedded Fiber Optic Sensors and Piezoelectric Transducers

    NASA Astrophysics Data System (ADS)

    Keulen, Casey James

    Advanced composite materials are becoming increasingly more valuable in a plethora of engineering applications due to properties such as tailorability, low specific strength and stiffness and resistance to fatigue and corrosion. Compared to more traditional metallic and ceramic materials, advanced composites such as carbon, aramid or glass reinforced plastic are relatively new and still require research to optimize their capabilities. Three areas that composites stand to benefit from improvement are processing, damage detection and life prediction. Fiber optic sensors and piezoelectric transducers show great potential for advances in these areas. This dissertation presents the research performed on improving the efficiency of advanced composite materials through the use of embedded fiber optic sensors and surface mounted piezoelectric transducers. Embedded fiber optic sensors are used to detect the presence of resin during the injection stage of resin transfer molding, monitor the degree of cure and predict the remaining useful life while in service. A sophisticated resin transfer molding apparatus was developed with the ability of embedding fiber optics into the composite and a glass viewing window so that resin flow sensors could be verified visually. A novel technique for embedding optical fiber into both 2- and 3-D structures was developed. A theoretical model to predict the remaining useful life was developed and a systematic test program was conducted to verify this model. A network of piezoelectric transducers was bonded to a composite panel in order to develop a structural health monitoring algorithm capable of detecting and locating damage in a composite structure. A network configuration was introduced that allows for a modular expansion of the system to accommodate larger structures and an algorithm based on damage progression history was developed to implement the network. The details and results of this research are contained in four manuscripts that

  13. Metal composite as backing for ultrasonic transducers dedicated to non-destructive measurements in hostile

    NASA Astrophysics Data System (ADS)

    Boubenia, R.; Rosenkrantz, E.; Despetis, F.; P, P.; Ferrandis, J.-Y.

    2016-03-01

    Our team is specialized in ultrasonic measurements in hostile environment especially under high temperatures. There is a need for acoustic transducers capable of continuous measurement at temperatures up to 700°C. To improve the performances of acoustic sensors we focus our works on the realisation and characterisation of transducer backings able to operate under very high temperature. Commercially, they are produced by the incorporation of tungsten powder in a plastic matrix, which limits the working temperature. The realisation of ultrasonic transducers for non-destructive measures at high temperatures requires adequate materials, manufacturing and assembly processes. To produce the backings, composites were made using very ductile metals such as tin and tungsten. These composites are manufactured by uniaxial hot pressing. First, we studied the influence of temperature and pressure on the densification of tin pellets. Then, several specimens made of tin/W were made and characterised by measuring the specific weight, speed and attenuation of sound. The acoustic measures were realised by ultrasonic spectroscopy. This test-bench was designed and tested on control samples of PMMA and on standard backings (epoxy / tungsten).

  14. Actuating Mechanism and Design of a Cylindrical Traveling Wave Ultrasonic Motor Using Cantilever Type Composite Transducer

    PubMed Central

    Liu, Yingxiang; Chen, Weishan; Liu, Junkao; Shi, Shengjun

    2010-01-01

    Background Ultrasonic motors (USM) are based on the concept of driving the rotor by a mechanical vibration excited on the stator via piezoelectric effect. USM exhibit merits such as simple structure, quick response, quiet operation, self-locking when power off, nonelectromagnetic radiation and higher position accuracy. Principal Findings A cylindrical type traveling wave ultrasonic motor using cantilever type composite transducer was proposed in this paper. There are two cantilevers on the outside surface of cylinder, four longitudinal PZT ceramics are set between the cantilevers, and four bending PZT ceramics are set on each outside surface of cantilevers. Two degenerate flexural vibration modes spatially and temporally orthogonal to each other in the cylinder are excited by the composite transducer. In this new design, a single transducer can excite a flexural traveling wave in the cylinder. Thus, elliptical motions are achieved on the teeth. The actuating mechanism of proposed motor was analyzed. The stator was designed with FEM. The two vibration modes of stator were degenerated. Transient analysis was developed to gain the vibration characteristic of stator, and results indicate the motion trajectories of nodes on the teeth are nearly ellipses. Conclusions The study results verify the feasibility of the proposed design. The wave excited in the cylinder isn't an ideal traveling wave, and the vibration amplitudes are inconsistent. The distortion of traveling wave is generated by the deformation of bending vibration mode of cylinder, which is caused by the coupling effect between the cylinder and transducer. Analysis results also prove that the objective motions of nodes on the teeth are three-dimensional vibrations. But, the vibration in axial direction is minute compared with the vibrations in circumferential and radial direction. The results of this paper can guide the development of this new type of motor. PMID:20368809

  15. Simulation and fabrication of 0-3 composite PZT films for ultrahigh frequency (100-300 MHz) ultrasonic transducers

    NASA Astrophysics Data System (ADS)

    Chen, Xiaoyang; Fei, Chunlong; Chen, Zeyu; Chen, Ruimin; Yu, Ping; Chen, Zhongping; Shung, K. Kirk; Zhou, Qifa

    2016-03-01

    This paper presents simulation, fabrication, and characterization of single-element ultrahigh frequency (100-300-MHz) needle ultrasonic transducers based on 0-3 composite Pb(Zr0.52Ti0.48)O3 (PZT) films prepared by using composite ceramic sol-gel film and sol-infiltration technique. The center frequency of the developed transducer at 300-MHz was the highest frequency of PbTiO3 ceramic-based ultrasonic transducers ever reported. Furthermore, a brief description of the composite model was followed by the development of a new expression for predicting the longitudinal velocity, the clamped dielectric constant, and the complex electromechanical coupling coefficient kt of these films, which is very important in ultrasonic transducer design. Moreover, these parameters are difficult to obtain by measuring the frequency dependence of impedance and phase angle because of the weak signal of the previous 0-3 composite films transducer (>100 MHz). The modeling results show that the Cubes model with a geometric factor n = 0.05 fits well with the measured data. This model will be helpful for developing the 0-3 composite systems for ultrahigh frequency ultrasonic transducer design.

  16. A full 3D plane-wave-expansion model for 1-3 piezoelectric composite structures.

    PubMed

    Wilm, Mikaël; Ballandras, Sylvain; Laude, Vincent; Pastureaud, Thomas

    2002-09-01

    The plane-wave-expansion (PWE) approach dedicated to the simulation of periodic devices has been extended to 1-3 connectivity piezoelectric composite structures. The case of simple but actual piezoelectric composite structures is addressed, taking piezoelectricity, acoustic losses, and electrical excitation conditions rigorously into account. The material distribution is represented by using a bidimensional Fourier series and the electromechanical response is simulated using a Bloch-Floquet expansion together with the Fahmy-Adler formulation of the Christoffel problem. Application of the model to 1-3 connectivity piezoelectric composites is reported and compared to previously published analyses of this problem. PMID:12243182

  17. Improving the thermal dimensional stability of flexible polymer composite backing materials for ultrasound transducers.

    PubMed

    State, Mihai; Brands, Peter J; van de Vosse, Frans N

    2010-04-01

    Novel ultrasound backing materials based on polymer composites with improved dimensional stability and low coefficient of thermal expansion are being developed and analyzed. For this purpose a filled epoxy resin (Stycast(1265)), a commonly used backing material, was considered reference material and polyurethane composites (PU(2305), PU(2350)) were proposed as better alternatives. When compared to the reference, the PU(2350) filled with a mixture of Al(2)O(3) and tungsten exhibited an approximately 15 times lower glassy transition temperature and a 2.5 time lower longitudinal thermal expansion at 20 degrees C. This ensures that within the entire operational temperature range the backing material is flexible, minimizing the thermal stresses induced onto transducer elements soldered joints and piezoceramic core. For the same material, the attenuation at 5MHz was similar to the reference material while at 7 and 8.5MHz it was 33% and 54% higher respectively. From these analyses it is concluded that the newly developed polyurethane composites outperform the reference backing with respect to the thermal dimensional stability as well as to the damping properties. An integrated rigorous mechano-acoustical approach is being proposed as an appropriate passive material design path. It can be easily extended to any other passive materials used for ultrasound transducer conception. PMID:19897218

  18. Microwave Plasma Chemical Vapor Deposition of Carbon Coatings on LiNi1/3Co1/3Mn1/3O2 for Li-Ion Battery Composite Cathodes

    SciTech Connect

    Doeff, M.M.; Kostecki, R.; Marcinek, M.; Wilcoc, J.D.

    2008-12-10

    In this paper, we report results of a novel synthesis method of thin film conductive carbon coatings on LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} cathode active material powders for lithium-ion batteries. Thin layers of graphitic carbon were produced from a solid organic precursor, anthracene, by a one-step microwave plasma chemical vapor deposition (MPCVD) method. The structure and morphology of the carbon coatings were examined using SEM, TEM, and Raman spectroscopy. The composite LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} electrodes were electrochemically tested in lithium half coin cells. The composite cathodes made of the carbon-coated LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} powder showed superior electrochemical performance and increased capacity compared to standard composite LiNi{sub 1/3}Co{sub 1/3}Mn{sub 1/3}O{sub 2} electrodes.

  19. Design of piezoelectric transducers for health monitoring of composite aircraft structures

    NASA Astrophysics Data System (ADS)

    Stepinski, Tadeusz; Engholm, Marcus

    2007-04-01

    Composite structures have become a significant part of modern lightweight aircrafts. Contrary to the aluminum panels such structures are susceptible to catastrophic failure without noticeable forewarnings. One possible way of preventing catastrophic failures is integrating health monitoring systems in the critical composite structures of the aircraft. Ultrasonic resonance inspection is especially suitable for the inspection of multilayered composite structures. In our previous works we have described the principle of narrow-band ultrasonic spectroscopy (NBUS), where the surface of an inspected structure is scanned with a resonant transducer whose frequency response is monitored in a narrow frequency band. It has been proven that the NBUS method is capable of detecting both artificial disbonds and real impact defects in carbon fiber composites. In this paper we present design guidelines for optimizing narrow-band electromechanical impedance (NBE/MI) sensors that are to be integrated with a monitored composite structure. The NBE/MI sensor takes the form of a piezoelectric element bonded to the monitored structure. Parameter variations in the inspected structure result in the respective variations of the electrical impedance (admittance) of the piezoelectric sensor. Relation between the state of the inspected structure and the sensor's admittance is estimated using the network representation. Conclusions concerning the proper choice of the operating frequencies suitable for various structures are presented.

  20. Fuel compositions containing maleic derivatives of 2,5-dimercapto-1,3,4-thiadiazole

    SciTech Connect

    Karol, T.J.

    1989-11-14

    This patent describes a diesel fuel composition. It is characterized by improved wear properties. It comprises: a major portion of middle distillates boiling in the range of about 163{degrees}to 400{degrees}C. and a minor wear improving amount of a reaction product of a maleic compound and 2,5-dimercapto-1,3,4-thiadiazole.

  1. Research of Ultrasound-Mediated Transdermal Drug Delivery System Using Cymbal-Type Piezoelectric Composite Transducer

    NASA Astrophysics Data System (ADS)

    Huan, Huiting; Gao, Chunming; Liu, Lixian; Sun, Qiming; Zhao, Binxing; Yan, Laijun

    2015-06-01

    Transdermal drug delivery (TDD) implemented by especially low-frequency ultrasound is generally known as sonophoresis or phonophoresis which has drawn considerable wide attention. However, TDD has not yet achieved its full potential as an alternative to conventional drug delivery methods due to its bulky instruments. In this paper, a cymbal-type piezoelectric composite transducer (CPCT) which has advantages over a traditional ultrasound generator in weight, flexibility, and power consumption, is used as a substitute ultrasonicator to realize TDD. First, theoretical research on a CPCT based on the finite element analysis was carried out according to which a series of applicable CPCTs with bandwidths of 20 kHz to 100 kHz were elaborated. Second, a TDD experimental setup was built with previously fabricated CPCTs aimed at the administration of glucose. Finally, the TDD performance of glucose molecule transport in porcine skin was measured in vitro by quantifying the concentration of glucose, and the time variation curves were subsequently obtained. During the experiment, the driving wave form, frequency, and power consumption of the transducers were selected as the main elements which determined the efficacy of glucose delivery. The results indicate that the effectiveness of the CPCT-based delivery is constrained more by the frequency and intensity of ultrasound rather than the driving waveform. The light-weight, flexibility, and low-power consumption of a CPCT can potentially achieve effective TDD.

  2. Fabrication and characterization of piezoelectric micromachined ultrasonic transducers with thick composite PZT films.

    PubMed

    Wang, Zhihong; Zhu, Weiguang; Zhu, Hong; Miao, Jianmin; Chao, Chen; Zhao, Changlei; Tan, Ooi Kiang

    2005-12-01

    Ferroelectric microelectromechanical systems (MEMS) has been a growing area of research in past decades, in which ferroelectric films are combined with silicon technology for a variety of applications, such as piezo-electric micromachined ultrasonic transducers (pMUTs), which represent a new approach to ultrasound detection and generation. For ultrasound-radiating applications, thicker PZT films are preferred because generative force and response speed of the diaphragm-type transducers increase with increasing film thickness. However, integration of 4- to 20-microm thick PZT films on silicon wafer, either the deposition or the patterning, is still a bottleneck in the micromachining process. This paper reports on a diaphragm-type pMUT. A composite coating technique based on chemical solution deposition and high-energy ball milled powder has been used to fabricate thick PZT films. Micromachining of the pMUTs using such thick films has been investigated. The fabricated pMUT with crack-free PZT films up to 7-microm thick was evaluated as an ultrasonic transmitter. The generated sound pressure level of up to 120 dB indicates that the fabricated pMUT has very good ultrasound-radiating performance and, therefore, can be used to compose pMUT arrays for generating ultrasound beam with high directivity in numerous applications. The pMUT arrays also have been demonstrated. PMID:16463494

  3. Study of Cymbal Piezoelectric Composite Transducer Based on Finite Element Analysis

    NASA Astrophysics Data System (ADS)

    Gong, Yanli; Gao, Chunming; Zhao, Binxing; Duan, Haiyang; Zhang, Liyan

    2013-09-01

    A cymbal piezoelectric composite transducer (CPCT) has been developed in recent years, which converts small radial deformation into larger longitudinal deformation. In this paper, the finite element analysis (FEA) method is used to analyze the characters of CPCT, by which the optimized CPCT has been made. Firstly, the FEA theory of a CPCT has been described, and the two-dimensional FEA model of a CPCT has been established by ANSYS. Secondly, the simulation and analysis about the relationships between structural parameters and displacement have been carried out, by which the CPCT samples have been made with optimized structure parameters. Thirdly, using laser interferometry, voltage-displacement relationships of CPCT samples have been measured. Finally, the displacement hysteresis and the aging behavior of a CPCT have been analyzed.

  4. PMN-PT–PZT composite films for high frequency ultrasonic transducer applications

    PubMed Central

    Hsu, Hsiu-Sheng; Benjauthrit, Vatcharee; Zheng, Fan; Chen, Rumin; Huang, Yuhong; Zhou, Qifa; Shung, K. Kirk

    2013-01-01

    We have successfully fabricated x(0.65PMN-0.35PT)–(1 − x)PZT (xPMN-PT–(1 − x)PZT), where x is 0.1, 0.3, 0.5, 0.7 and 0.9, thick films with a thickness of approximately 9 µm on platinized silicon substrate by employing a composite sol–gel technique. X-ray diffraction analysis and scanning electron microscopy revealed that these films are dense and creak-free with well-crystallized perovskite phase in the whole composition range. The dielectric constant can be controllably adjusted by using different compositions. Higher PZT content of xPMN-PT–(1 − x)PZT films show better ferroelectric properties. A representative 0.9PMN-PT–0.1PZT thick film transducer is built. It has 200 MHz center frequency with a −6 dB bandwidth of 38% (76 MHz). The measured two-way insertion loss is 65 dB. PMID:23750072

  5. Flexible ultrasonic transducers for structural health monitoring of metals and composites

    NASA Astrophysics Data System (ADS)

    Kobayashi, M.; Wu, K.-T.; Shih, J.-L.; Jen, C.-K.; Kruger, S. E.

    2010-03-01

    Flexible ultrasonic transducers (FUTs) which have the on-site installation capability are presented for the non-destructive evaluation (NDE) and structural health monitoring (SHM) purposes. These FUTs consist of 75 μm thick titanium membrane, thick (> 70 μm) thick piezoelectric lead-zirconate-titanate (PZT) composite (PZT-c) films and thin (< 5 μm) thick top electrodes. The PZT-c films are made by a sol-gel spray technique. Such FUT has been glued onto a steel pipe of 101 mm in diameter and 4.5 mm in wall thickness and operated up to 200°C. The glue served as high temperature ultrasonic couplant between the FUT and the external surface of the pipe. The estimated pipe thickness measurement accuracy at 200°C is 34 μm. FUTs also were glued onto the end edge of 2 mm thick aluminum (Al) plates to generate and receive predominantly symmetrical and shear-horizontal (SH) plate acoustic waves (PAWs) to detect simulated line defects at temperature up to 100°C. FUTs glued onto a graphite/epoxy (Gr/Ep) composite are also used for the detection of artificial disbonds. An induction type non-contact method for the evaluation of Al plates and Gr/Ep composites using FUTs is also demonstrated.

  6. PMN-PT-PZT composite films for high frequency ultrasonic transducer applications.

    PubMed

    Hsu, Hsiu-Sheng; Benjauthrit, Vatcharee; Zheng, Fan; Chen, Rumin; Huang, Yuhong; Zhou, Qifa; Shung, K Kirk

    2012-06-01

    We have successfully fabricated x(0.65PMN-0.35PT)-(1 - x)PZT (xPMN-PT-(1 - x)PZT), where x is 0.1, 0.3, 0.5, 0.7 and 0.9, thick films with a thickness of approximately 9 µm on platinized silicon substrate by employing a composite sol-gel technique. X-ray diffraction analysis and scanning electron microscopy revealed that these films are dense and creak-free with well-crystallized perovskite phase in the whole composition range. The dielectric constant can be controllably adjusted by using different compositions. Higher PZT content of xPMN-PT-(1 - x)PZT films show better ferroelectric properties. A representative 0.9PMN-PT-0.1PZT thick film transducer is built. It has 200 MHz center frequency with a -6 dB bandwidth of 38% (76 MHz). The measured two-way insertion loss is 65 dB. PMID:23750072

  7. Image analysis of the microstructure of pseudo-1-3 magnetostrictive composites

    NASA Astrophysics Data System (ADS)

    Dong, Xufeng; Qi, Min; Guan, Xinchun; Ou, Jinping

    2010-04-01

    Previous studies did by some scholars proved applying a magnetic field during the manufacture process of polymer-bonded Terfenol-D could orient the magnetic easy direction of the particles along the field direction and form a pseudo-1-3 structure. Compared to the 0-3 composites composed of Terfenol-D particles dispersed randomly in a polymer matrix, pseudo-1-3 magnetostrictive composites present much larger magnetostrictive performance. In this paper, magnetostrictive composites based on Terfenol-D particles in an unsaturated polyester resin matrix were fabricated under different magnetic fields. Magentostriction was tested and compared to get the detail effects of orientation fields on magnetostrictive properties of magnetostrictive composites. Scanning electron microscopy was used to observe their microstructures. Image analysis was applied to describe the microstructures. The distribution of the angles between the major axis of the particles and the magnetic field direction was used to evaluate the arrangement of particles in the matrix quantitatively. The results confirm particle chain-like structures in composites prepared under larger magnetic field, and show that particle arrangement changes with the strength of the orientation field, which is result in the changes of magnetostrictive performance.

  8. Tunable phononic crystals based on piezoelectric composites with 1-3 connectivity.

    PubMed

    Croënne, Charles; Ponge, Marie-Fraise; Dubus, Bertrand; Granger, Christian; Haumesser, Lionel; Levassort, Franck; Vasseur, Jérôme O; Lordereau, Albert; Pham Thi, Mai; Hladky-Hennion, Anne-Christine

    2016-06-01

    Phononic crystals made of piezoelectric composites with 1-3 connectivity are studied theoretically and experimentally. It is shown that they present Bragg band gaps that depend on the periodic electrical boundary conditions. These structures have improved properties compared to phononic crystals composed of bulk piezoelectric elements, especially the existence of larger band gaps and the fact that they do not require severe constraints on their aspect ratios. Experimental results present an overall agreement with the theoretical predictions and clearly show that the pass bands and stop bands of the device under study are easily tunable by only changing the electrical boundary conditions applied on each piezocomposite layer. PMID:27369154

  9. Intestinal Bile Acid Composition Modulates Prohormone Convertase 1/3 (PC1/3) Expression and Consequent GLP-1 Production in Male Mice.

    PubMed

    Morimoto, Kohkichi; Watanabe, Mitsuhiro; Sugizaki, Taichi; Irie, Jun-ichiro; Itoh, Hiroshi

    2016-03-01

    Besides an established medication for hypercholesterolemia, bile acid binding resins (BABRs) present antidiabetic effects. Although the mechanisms underlying these effects are still enigmatic, glucagon-like peptide-1 (GLP-1) appears to be involved. In addition to a few reported mechanisms, we propose prohormone convertase 1/3 (PC1/3), an essential enzyme of GLP-1 production, as a potent molecule in the GLP-1 release induced by BABRs. In our study, the BABR colestimide leads to a bile acid-specific G protein-coupled receptor TGR5-dependent induction of PC1/3 gene expression. Here, we focused on the alteration of intestinal bile acid composition and consequent increase of total TGR5 agonistic activity to explain the TGR5 activation. Furthermore, we demonstrate that nuclear factor of activated T cells mediates the TGR5-triggered PC1/3 gene expression. Altogether, our data indicate that the TGR5-dependent intestinal PC1/3 gene expression supports the BABR-stimulated GLP-1 release. We also propose a combination of BABR and dipeptidyl peptidase-4 inhibitor in the context of GLP-1-based antidiabetic therapy. PMID:26789236

  10. Structural Diagnostics of CFRP Composite Aircraft Components by Ultrasonic Guided Waves and Built-In Piezoelectric Transducers

    SciTech Connect

    Howard M. Matt

    2007-02-15

    To monitor in-flight damage and reduce life-cycle costs associated with CFRP composite aircraft, an autonomous built-in structural health monitoring (SHM) system is preferred over conventional maintenance routines and schedules. This thesis investigates the use of ultrasonic guided waves and piezoelectric transducers for the identification and localization of damage/defects occurring within critical components of CFRP composite aircraft wings, mainly the wing skin-to-spar joints. The guided wave approach for structural diagnostics was demonstrated by the dual application of active and passive monitoring techniques. For active interrogation, the guided wave propagation problem was initially studied numerically by a semi-analytical finite element method, which accounts for viscoelastic damping, in order to identify ideal mode-frequency combinations sensitive to damage occurring within CFRP bonded joints. Active guided wave tests across three representative wing skin-to-spar joints at ambient temperature were then conducted using attached Macro Fiber Composite (MFC) transducers. Results from these experiments demonstrate the importance of intelligent feature extraction for improving the sensitivity to damage. To address the widely neglected effects of temperature on guided wave base damage identification, analytical and experimental analyses were performed to characterize the influence of temperature on guided wave signal features. In addition, statistically-robust detection of simulated damage in a CFRP bonded joint was successfully achieved under changing temperature conditions through a dimensionally-low, multivariate statistical outlier analysis. The response of piezoceramic patches and MFC transducers to ultrasonic Rayleigh and Lamb wave fields was analytically derived and experimentally validated. This theory is useful for designing sensors which possess optimal sensitivity toward a given mode-frequency combination or for predicting the frequency dependent

  11. Structural diagnostics of CFRP composite aircraft components by ultrasonic guided waves and built-in piezoelectric transducers

    NASA Astrophysics Data System (ADS)

    Matt, Howard M.

    2006-07-01

    To monitor in-flight damage and reduce life-cycle costs associated with CFRP composite aircraft, an autonomous built-in structural health monitoring (SHM) system is preferred over conventional maintenance routines and schedules. This thesis investigates the use of ultrasonic guided waves and piezoelectric transducers for the identification and localization of damage/defects occurring within critical components of CFRP composite aircraft wings, mainly the wing skin-to-spar joints. The guided wave approach for structural diagnostics was demonstrated by the dual application of active and passive monitoring techniques. For active interrogation, the guided wave propagation problem was initially studied numerically by a semi-analytical finite element method, which accounts for viscoelastic damping, in order to identify ideal mode-frequency combinations sensitive to damage occurring within CFRP bonded joints. Active guided wave tests across three representative wing skin-to-spar joints at ambient temperature were then conducted using attached Macro Fiber Composite (MFC) transducers. Results from these experiments demonstrate the importance of intelligent feature extraction for improving sensitivity to damage. To address the widely neglected effects of temperature on guided wave base damage identification, analytical and experimental analyses were performed to characterize the influence of temperature on guided wave signal features. In addition, statistically-robust detection of simulated damage in a CFRP bonded joint was successfully achieved under changing temperature conditions through a dimensionally-low, multivariate statistical outlier analysis. The response of piezoceramic patches and MFC transducers to ultrasonic Rayleigh and Lamb wave fields was analytically derived and experimentally validated. This theory is useful for designing sensors which possess optimal sensitivity toward a given mode-frequency combination or for predicting the frequency dependent

  12. Study of BNKLBT-1.5 lead-free ceramic/epoxy 1-3 composites

    SciTech Connect

    Choy, S. H.; Li, W. K.; Li, H. K.; Lam, K. H.; Chan, H. L. W.

    2007-12-01

    Bismuth sodium titanate based lead-free ceramic fiber with the chemical formula of 0.885(Bi{sub 0.5}Na{sub 0.5})TiO{sub 3}-0.05(Bi{sub 0.5}K{sub 0.5})TiO{sub 3}-0.015(Bi{sub 0.5}Li{sub 0.5}= )TiO{sub 3}-0.05BaTiO{sub 3}, BNKLBT-1.5, has been fabricated by a powder-based extrusion method. The ceramic fibers with 400 {mu}m diameter were well crystallized after being calcined at 800 deg. C and sintered at 1170 deg. C. The piezoelectric and ferroelectric properties of the single fiber were found to be 155 pC/N and {approx}34.5 {mu}C/cm{sup 2}, respectively, which is comparable with that in bulk sample. 1-3 ceramic/polymer composites were fabricated by two routes, including dice and filled method and fiber pick-and-place method. Theoretical models were used to calculate the piezoelectric properties of the composites and compared with experimental results.

  13. Innovations in piezoelectric materials for ultrasound transducers

    NASA Astrophysics Data System (ADS)

    Shrout, Thomas R.; Park, Seung Eek E.; Lopath, Patrick D.; Meyer, Richard J., Jr.; Ritter, Timothy A.; Shung, K. Kirk

    1998-05-01

    Piezoelectric material lie at the heart of ultrasonic transducers. Recent advances in materials development include submicron piezoelectric ceramics (PZT) which lead to improvements in feature size, i.e. aspect ratio, element width, etc., for linear arrays and high frequency transducers. In contrast to fine grain ceramics, single crystal materials based on Relaxor-PT ferroelectrics offer electromechanical coupling coefficients > 90 percent with a range of dielectric permittivity allowing flexibility in transducer engineering in regard to electrical impedance matching. Using KLM modeling, very high bandwidth performance > 120 percent is projected. Specific examples of high frequency 1-3 composites and 1D linear array transducers fabricated from new piezoelectric materials, including sol-gel derived PZT fibers, are presented.

  14. Smart damping of geometrically nonlinear vibrations of laminated composite beams using vertically reinforced 1-3 piezoelectric composites

    NASA Astrophysics Data System (ADS)

    Sarangi, S. K.; Ray, M. C.

    2010-07-01

    This paper deals with the analysis of active constrained layer damping (ACLD) of geometrically nonlinear transient vibrations of laminated composite beams using vertically reinforced 1-3 piezoelectric composite material as the material of the constraining layer of the ACLD treatment. A nonlinear finite element model has been developed for analyzing the ACLD of laminated symmetric and antisymmetric cross-ply and angle-ply composite beams integrated with such ACLD treatment. The von Kármán-type nonlinear strain-displacement relations and the first-order shear deformation theory are used for deriving this coupled electromechanical nonlinear finite element model. The Golla-Hughes-McTavish (GHM) method has been used to model the constrained viscoelastic layer of the ACLD treatment in the time domain. The backbone curves of such a class of nonlinear systems are plotted to determine the excitation levels for causing geometrical nonlinearity. The numerical results reveal that the ACLD treatment significantly improves the damping characteristics of the cross-ply and antisymmetric angle-ply beams for suppressing the geometrically nonlinear transient vibrations of the beams.

  15. A vibration energy harvester using five-phase laminate composite transducer based on nanocrystalline soft magnetic alloy

    NASA Astrophysics Data System (ADS)

    Qiu, Jing; Wen, Yumei; Li, Ping; Chen, Hengjia; Yang, Jin

    2015-05-01

    In this research, a vibration energy harvester employing the FeCuNbSiB/Terfenol-D/PZT/Terfenol-D/FeCuNbSiB five-phase laminate composite transducer to convert mechanical vibration energy into electrical energy was presented. The electric output performance of the proposed vibration energy harvester has been investigated. It was found that appropriate FeCuNbSiB layer thickness was propitious to the electric output characteristics. Compared to traditional vibration energy harvester using Terfenol-D/PZT/Terfenol-D (MPM) transducer, the experimental results show that the proposed vibration energy harvester provides a remarkably enhanced output power performance. When the thickness of FeCuNbSiB layer was 30 μm, the optimum output power of vibration energy harvester achieved 4.00 mW/g for an acceleration of 0.8 g at frequency of 34.5 Hz, which was 1.29 times as great as that of traditional MPM transducer. Remarkably, this power is a very encouraging power figure and the proposed vibration energy harvester has great potential as far as its application in wireless sensor network.

  16. Experimental Study of Acoustic Properties of (0-3) Composite Materials for Intermediate Layer or Backing of Ultrasonic Transducers

    NASA Astrophysics Data System (ADS)

    Sugawara, Keisuke; Nishihira, Morimasa; Imano, Kazuhiko

    2005-06-01

    The acoustic properties of composite materials used for an intermediate layer or backing of an ultrasonic transducer are studied experimentally. (0-3) composite materials are formed from a mixture of epoxy resin and tungsten powder for various weight ratios and their acoustic properties are measured. The experimental results are compared with the results predicted by different models, which are based on the elastic-wave scattering theory, to verify if the measured acoustic properties agree with theoretical estimations. For the ultrasonic velocities, the estimations of the Devaney model were closest to the experimental results. The weight fractions of tungsten powder for the composite materials, which have objective acoustic properties, can easily be estimated by theoretical calculations using the Devaney model.

  17. Characterization of PMN-PT piezoelectric single crystal and PMN-PT 1-3 composite at elevated temperatures by electrical impedance resonance analysis.

    PubMed

    Wu, Zhengbin; Xi, Kui

    2014-07-01

    In this paper, lead magnesium niobate-lead titanate (PMN-PT) piezoelectric single crystal and its 1-3 composite counterpart were characterized and analyzed under different stable temperatures using both a Simulated Annealing (SA) optimization algorithm and the commercial software PRAP (Piezoelectric Resonance Analysis Program). Electrical impedance resonance characteristics of the two material samples over the range 25-125 °C were measured. The correlation between experimental data and numerical fits derived from both SA and PRAP is considered. Calculation of the determination coefficient (R1(2)) between numerically fitted and measured results is above 95% for both methods. Furthermore, variations in the number of data values used for the fit introduced no more than 3.1% uncertainty on the calculated material parameters. It is found that the complex material parameters of PMN-PT composite are more dependent on temperature than the single crystal. The phase transition of the PMN-PT, which is close to 90 °C, has an effect on the high temperature material characteristics of both piezoelectric materials. These calculated complex material parameters can be used for the design of ultrasonic transducers for elevated temperature applications. PMID:24495996

  18. Transducer characterization

    SciTech Connect

    Cross, B. T.; Eoff, J. M.; Schuetz, L. J.; Cunningham, K. R.

    1980-07-02

    This report has been prepared specifically for ultrasonic transducer users within the Nondestructive Testing Evaluation (NDE) community of the weapons complex. The purpose of the report is to establish an initial set of uniform procedures for measuring and recording transducer performance data, and to establish a common foundation on which more comprehensive transducer performance evaluations may be added as future transducer performance criteria expands. Transducer parameters and the problems with measuring them are discussed and procedures for measuring transducer performance are recommended with special precautionary notes regarding critical aspects of each measurement. An important consideration regarding the recommended procedures is the cost of implementation. There are two distinct needs for transducer performance characterization in the complex. Production oriented users need a quick, reliable means to check a transducer to ascertain its suitability for continued service. Development groups and the Transducer Center need a comprehensive characterization means to collect adequate data to evaluate theoretical concepts or to build exact replacement transducers. The instrumentation, equipment, and procedures recommended for monitoring production transducers are utilitarian and provide only that information needed to determine transducer condition.

  19. Fingerprint test data report: FM 5834 test lots No. 1, 3, 4, and 5. [resin matrix composites

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Quality control testing is presented for various lots of resin matrix composites. The tests conducted were filler test, resin test, fabric test, and prepreg test for lots 1, 3, 4, and 5. The results of the tests are presented in chart forms.

  20. 1-3 connectivity composite material made from lithium niobate and cement for ultrasonic condition monitoring at elevated temperatures.

    PubMed

    Shepherd, G; Cochran, A; Kirk, K J; McNab, A

    2002-05-01

    We have designed, manufactured and tested a piezoelectric composite material to operate at temperatures above 400 degrees C. The material is a 1-3 connectivity composite with pillars of Z-cut lithium niobate in a matrix of alumina cement. The composite material produced shorter pulses than a monolithic plate of lithium niobate and remained intact upon cooling. Results are presented from room temperature and high temperature testing. This material could be bonded permanently to a test object, making it possible to carry out condition monitoring over an extended period. A new excitation method was also developed to enable remote switching between array elements. PMID:12159936

  1. The effect of polymeric filler on poling behavior and thermal stability of 1-3 piezoelectric composites

    NASA Astrophysics Data System (ADS)

    Wang, Chunying; Zhang, Rui; Jing, Yujia; Cao, Wenwu

    2016-01-01

    In this paper, the influence of polymeric filler with different glass transition temperature (T g) on the poling behavior and thermal stability of 1-3 piezoelectric composites were investigated, with emphasis on the relationship between T g and temperature dependent properties. The results revealed that high poling temperature improves the piezoelectric coefficient by nearly 12% for composites filled with epoxy (Epotek301, T g above room temperature). On the contrary, high temperature gives a negative impact on the poling of composites filled with rubber (Ke45W, T g below room temperature). In addition, it was found that rubber-filled composites possess better temperature stability between room temperature to140 °C, including dielectric and electromechanical properties, compared with epoxy-filled composites.

  2. Non-methane exhaust composition in the sydney harbour tunnel: A focus on benzene and 1,3-butadiene

    NASA Astrophysics Data System (ADS)

    Duffy, Bronwyn L.; Nelson, Peter F.

    The concentrations of individual hydrocarbon species in the Sydney Harbour Tunnel were measured and used to estimate the average composition of emissions from moving motor vehicles in the Sydney urban area. The mean composition of non-methane hydrocarbons in the tunnel air on a weight basis was relatively constant. The mean concentrations for benzene and 1,3-butadiene were 45 and 13 ppbv, respectively, which in turn represented ˜ 5.2% w/w and ˜ 1.0% w/w of the total non-methane C 2C 10 hydrocarbons in the tunnel air. The unit risk factor and the maximum incremental reactivity factor for 1 1,3-butadiene are approximately 30 times higher and 25 times higher, respectively, than the corresponding values for benzene. The concentration (μg m -3) of benzene, however, is only about 5 times that of 1,3-butadiene. On this basis, the relative contribution to the risk associated with exposure to fresh motor vehicle emissions in Sydney would be about 6 times higher for 1,3-butadiene than for benzene. Similarly, the contribution made by 1,3-butadiene to the total hydrocarbon reactivity of the tunnel air will be about 5 times that of benzene. Samples of three different grades of petrol (leaded, unleaded and premium unleaded) from three different brands of fuel were also analysed on two separate occasions. Compositions of leaded and standard unleaded petrol averaged across the three different brands are quite similar. The average aromatic content (% w/w) of the 3 different commercial brands were ˜ 35 and 30% for leaded and unleaded petrol, respectively. However, premium unleaded petrol has a much higher aromatic content of ˜ 47% w/w. Comparison of the petrol and tunnel compositions demonstrated that benzene is enriched relative to other aromatics in exhaust compared to its proportion in the petrol.

  3. Silver Doped 0.9PMN-PT-0.1PZT Composite Films for very High Frequency Ultrasonic Transducer Applications

    PubMed Central

    Hsu, Hsiu-Sheng; Benjauthrit, Vatcharee; Wei, Qiang; Huang, Yuhong; Zhou, Qifa; Shung, K. Kirk

    2013-01-01

    A series of silver doping concentration into the 0.9PMN-PT-0.1PZT (PMN-PT-PZT) films via the composite sol-gel technique were prepared. The crystallographic properties and microstructures of PMN-PT-PZT films with the silver dopant were investigated. Additionally, the effect of silver doping on dielectric and ferroelectric properties was examined. The results show that in general, the dielectric permittivity and remnant polarization increase as the silver doping concentration is increased. The PMN-PT-PZT+ 2.5 mol% Ag film exhibits a dielectric constant of 3,610 at 1 kHz and a remnant polarization of 57.6 µC/cm2 at room temperature. From this silver doped film, very high frequency ultrasonic needle transducers were fabricated and evaluated. The representative transducer had the center frequency of 225 MHz with a −6 dB bandwidth of 29% (65 MHz) and 62 dB insertion loss. The performance of this transducer is comparable to other composite sol-gel films transducer. The results suggest that this silver-doped PMN-PT-PZT film is a promising candidate as an alternative piezoelectric film for very high frequency transducer applications. PMID:23814408

  4. Silver Doped 0.9PMN-PT-0.1PZT Composite Films for very High Frequency Ultrasonic Transducer Applications.

    PubMed

    Hsu, Hsiu-Sheng; Benjauthrit, Vatcharee; Wei, Qiang; Huang, Yuhong; Zhou, Qifa; Shung, K Kirk

    2013-05-01

    A series of silver doping concentration into the 0.9PMN-PT-0.1PZT (PMN-PT-PZT) films via the composite sol-gel technique were prepared. The crystallographic properties and microstructures of PMN-PT-PZT films with the silver dopant were investigated. Additionally, the effect of silver doping on dielectric and ferroelectric properties was examined. The results show that in general, the dielectric permittivity and remnant polarization increase as the silver doping concentration is increased. The PMN-PT-PZT+ 2.5 mol% Ag film exhibits a dielectric constant of 3,610 at 1 kHz and a remnant polarization of 57.6 µC/cm(2) at room temperature. From this silver doped film, very high frequency ultrasonic needle transducers were fabricated and evaluated. The representative transducer had the center frequency of 225 MHz with a -6 dB bandwidth of 29% (65 MHz) and 62 dB insertion loss. The performance of this transducer is comparable to other composite sol-gel films transducer. The results suggest that this silver-doped PMN-PT-PZT film is a promising candidate as an alternative piezoelectric film for very high frequency transducer applications. PMID:23814408

  5. Silver doped 0.9PMN-PT-0.1PZT composite films for very high frequency ultrasonic transducer applications

    NASA Astrophysics Data System (ADS)

    Hsu, Hsiu-Sheng; Benjauthrit, Vatcharee; Wei, Qiang; Huang, Yuhong; Zhou, Qifa; Shung, K. Kirk

    2013-05-01

    A series of silver doping concentration into the 0.9PMN-PT-0.1PZT (PMN-PT-PZT) films via the composite sol-gel technique were prepared. The crystallographic properties and microstructures of PMN-PT-PZT films with the silver dopant were investigated. Additionally, the effect of silver doping on dielectric and ferroelectric properties was examined. The results show that in general, the dielectric permittivity and remnant polarization increase as the silver doping concentration is increased. The PMN-PT-PZT+2.5 mol% Ag film exhibits a dielectric constant of 3,610 at 1 kHz and a remnant polarization of 57.6 μC/cm2 at room temperature. From this silver doped film, very high frequency ultrasonic needle transducers were fabricated and evaluated. The representative transducer had the center frequency of 225 MHz with a -6 dB bandwidth of 29 % (65 MHz) and 62 dB insertion loss. The performance of this transducer is comparable to other composite sol-gel films transducer. The results suggest that this silver-doped PMN-PT-PZT film is a promising candidate as an alternative piezoelectric film for very high frequency transducer applications.

  6. Self-biased magnetoelectric coupling characteristics of three-phase composite transducers with nanocrystallin soft magnetic alloy

    NASA Astrophysics Data System (ADS)

    Huang, Dongyan; Lu, Caijiang; Bing, Han

    2015-07-01

    This paper reports the self-biased magnetoelectric (ME) effects in composites consisting of high-permeability Fe-based nanocrystalline soft magnetic alloy Fe73.5Cu1Nb3Si13.5B9 (FeCuNbSiB), pure nickel (Ni) and piezoelectric lead zirconate titanate (PZT). The FeCuNbSiB ribbons are fabricated on traditional laminates Ni/PZT/Ni through two modes: the attached mode (F-NPN-F) and the laminated mode (F/NPN/F). The F-NPN-F composite sufficiently reveals that the high-permeability FeCuNbSiB ribbons concentrate more magnetic flux in magnetostrictive Ni, which results in the self-biased ME effects of F-NPN-F. For the F/NPN/F composite, the FeCuNbSiB acts as the dynamic driver to enhance the effective piezomagnetic coefficient of Ni. The giant self-biased ME effects of F/NPN/F are because of the internal magnetic field between Ni and FeCuNbSiB due to their different magnetic characteristics. The influences of the numbers of FeCuNbSiB layers ( L) on the resonant ME voltage coefficients ( α ME ,r ) for F-NPN-F and F/NPN/F composites are investigated in detail. The experiments demonstrate that the maximum α ME ,r at zero-biased field is 80 V/cm Oe for F-NPN-F with L = 2, and 85 V/cm Oe for F/NPN/F with L = 4. This paper demonstrates that these two ME composites are suitable for achieving zero-biased ME transducers, power-free magnetic field sensors and energy harvesters.

  7. Development of fine scale PZT ceramic fiber/polymer shell composite transducers

    SciTech Connect

    Livneh, S.S.; Janas, V.F.; Safari, A.

    1995-07-01

    The relic processing technique was used to fabricate fine-scale piezoelectric lead zirconate titanate (PZT) ceramic fiber/polymer shell composites. In this technique sacrificial activated carbon fabrics were soaked in a PZT precursor solution, dried, and heat treated to form piezoceramic relics. Relics were embedded with polymer, which was allowed to cure, and the resulting composites were polished, electroded, and poled. Different facets of the composite-forming process were examined: structural modifications, soaking, firing, and polymer impregnation. The physical and electromechanical properties of the unique resulting composite were evaluated. Optimized PZT shell composites with 39 vol% ceramic exhibited the following property values: K{approximately}200, tan {delta} {approximately} 5.5%, d{sub 33} {approximately} 290 pC/N, d{sub h} {approximately} 100 pC/N, d{sub h}g{sub h} {approximately} 6000 {times} 10 {sup {minus}15} m{sup 2}/N, k{sub p} {approximately} 0.19, and k{sub t} {approximately} 0.28.

  8. Microinterferometer transducer

    DOEpatents

    Corey, III, Harry S.

    1979-01-01

    An air-bearing microinterferometer transducer is provided for increased accuracy, range and linearity over conventional displacement transducers. A microinterferometer system is housed within a small compartment of an air-bearing displacement transducer housing. A movable cube corner reflector of the interferometer is mounted to move with the displacement gauging probe of the transducer. The probe is disposed for axial displacement by means of an air-bearing. Light from a single frequency laser is directed into an interferometer system within the transducer housing by means of a self-focusing fiber optic cable to maintain light coherency. Separate fringe patterns are monitored by a pair of fiber optic cables which transmit the patterns to a detecting system. The detecting system includes a bidirectional counter which counts the light pattern fringes according to the direction of movement of the probe during a displacement gauging operation.

  9. Broadband and High Sensitive Time-of-Flight Diffraction Ultrasonic Transducers Based on PMNT/Epoxy 1–3 Piezoelectric Composite

    PubMed Central

    Liu, Dongxu; Yue, Qingwen; Deng, Ji; Lin, Di; Li, Xiaobing; Di, Wenning; Wang, Xi’an; Zhao, Xiangyong; Luo, Haosu

    2015-01-01

    5–6 MHz PMNT/epoxy 1–3 composites were prepared by a modified dice-and-fill method. They exhibit excellent properties for ultrasonic transducer applications, such as ultrahigh thickness electromechanical coupling coefficient kt (85.7%), large piezoelectric coefficient d33 (1209 pC/N), and relatively low acoustic impedance Z (1.82 × 107 kg/(m2·s)). Besides, two types of Time-of-Flight Diffraction (TOFD) ultrasonic transducers have been designed, fabricated, and characterized, which have different matching layer schemes with the acoustic impedance of 4.8 and 5.7 × 106 kg/(m2·s), respectively. In the detection on a backwall of 12.7 mm polystyrene, the former exhibits higher detectivity, the relative pulse-echo sensitivity and −6 dB relative bandwidth are −21.93 dB and 102.7%, respectively, while the later exhibits broader bandwidth, the relative pulse-echo sensitivity and −6 dB relative bandwidth are −24.08 dB and 117.3%, respectively. These TOFD ultrasonic transducers based on PMNT/epoxy 1–3 composite exhibit considerably improved performance over the commercial PZT/epoxy 1–3 composite TOFD ultrasonic transducer. PMID:25808776

  10. A 1-3 Piezoelectric Fiber Reinforced Carbon Nanotube Composite Sensor for Crack Monitoring

    NASA Astrophysics Data System (ADS)

    Makireddi, Sai; Balasubramaniam, Krishnan

    2016-07-01

    A method for the detection of location and size of a crack in simple structures using a nanocomposite sensor is discussed. In the present study, a piezoelectric/single walled carbon nanotube composite sensor is modeled on piezoelectric principle. The effective piezoelectric and dielectric properties of the composite at 0.2 volume fraction loading of single walled carbon nanotubes is determined by micromechanical analysis. By means of these effective properties a piezoelectric sensor has been modeled. The transfer function and bode response of this sensor is investigated. The sensor is fixed at a location on a cantilever beam and the response of the sensor with respect to the size and location of the crack is modeled. The analytical values are compared with ANSYS. It is assumed that there is no slippage between the sensor and the beam surface. The sensor behavior with respect to dynamic loading conditions is also studied. It is ascertained that the relative position of the sensor with respect to crack is crucial and determines the sensitivity of the sensor to detect a crack. Results are presented in the form of voltage output from the sensor at different crack locations and at varying lengths of the crack.

  11. A 1-3 Piezoelectric Fiber Reinforced Carbon Nanotube Composite Sensor for Crack Monitoring

    NASA Astrophysics Data System (ADS)

    Makireddi, Sai; Balasubramaniam, Krishnan

    2016-02-01

    A method for the detection of location and size of a crack in simple structures using a nanocomposite sensor is discussed. In the present study, a piezoelectric/single walled carbon nanotube composite sensor is modeled on piezoelectric principle. The effective piezoelectric and dielectric properties of the composite at 0.2 volume fraction loading of single walled carbon nanotubes is determined by micromechanical analysis. By means of these effective properties a piezoelectric sensor has been modeled. The transfer function and bode response of this sensor is investigated. The sensor is fixed at a location on a cantilever beam and the response of the sensor with respect to the size and location of the crack is modeled. The analytical values are compared with ANSYS. It is assumed that there is no slippage between the sensor and the beam surface. The sensor behavior with respect to dynamic loading conditions is also studied. It is ascertained that the relative position of the sensor with respect to crack is crucial and determines the sensitivity of the sensor to detect a crack. Results are presented in the form of voltage output from the sensor at different crack locations and at varying lengths of the crack.

  12. Damage progression during static and fatigue loading in metal matrix composites, volumes 1-3

    SciTech Connect

    Bakuckas, J.G., Jr.

    1991-01-01

    The objective is to gain a rational understanding of the damage initiation and progression in a variety of metal matrix composites (MMC) during both static and fatigue loading. An extensive two prong investigation involving experimental and analytical phases was undertaken in order to characterize damage progression in center notched MMC. Experimentally, the crack tip damage growth was studied utilizing several techniques including optical observations, use of the laser interferometric displacement gauge, acoustic emission, and fractography. The effects of heat treatment, constituents, and laminate configuration are addressed. In the analytical phase, the mechanics which govern the onset of damage formation in center cracked unidirectional MMC monolayers are predicted. A unique analytical technique to numerically simulate the subsequent damage progression is presented which manifests the individual microfailure mechanisms and their interaction in the evolution of the failure process ahead of an existing crack. Numerical simulations of the failure process was performed in several center-cracked unidirectional monolayered composites. The numerical simulations are correlated with experimental results in terms of the observed failure process, the notched strength, and load-COD data. Excellent agreement between the optical observations and the numerical simulation of the failure process was obtained. The numerical simulations captured the salient features observed in the sequential failure process. When correlated with the experimental results, the numerical simulations provided a better insight into the failure process in MMC. The appropriate selection of constituent components in the development of damage tolerant MMC for a particular application can be achieved by using this numerical technique.

  13. A laser ultrasound transducer using carbon nanofibers–polydimethylsiloxane composite thin film

    SciTech Connect

    Hsieh, Bao-Yu; Kim, Jinwook; Li, Sibo; Jiang, Xiaoning; Zhu, Jiadeng; Zhang, Xiangwu

    2015-01-12

    The photoacoustic effect has been broadly applied to generate high frequency and broadband acoustic waves using lasers. However, the efficient conversion from laser energy to acoustic power is required to generate acoustic waves with high intensity acoustic pressure (>10 MPa). In this study, we demonstrated laser generated high intensity acoustic waves using carbon nanofibers–polydimethylsiloxane (CNFs-PDMS) thin films. The average diameter of the CNFs is 132.7 ± 11.2 nm. The thickness of the CNFs film and the CNFs-PDMS composite film is 24.4 ± 1.43 μm and 57.9 ± 2.80 μm, respectively. The maximum acoustic pressure is 12.15 ± 1.35 MPa using a 4.2 mJ, 532 nm Nd:YAG pulsed laser. The maximum acoustic pressure using the CNFs-PDMS composite was found to be 7.6-fold (17.62 dB) higher than using carbon black PDMS films. Furthermore, the calculated optoacoustic energy conversion efficiency K of the prepared CNFs-PDMS composite thin films is 15.6 × 10{sup −3 }Pa/(W/m{sup 2}), which is significantly higher than carbon black-PDMS thin films and other reported carbon nanomaterials, carbon nanostructures, and metal thin films. The demonstrated laser generated high intensity ultrasound source can be useful in ultrasound imaging and therapy.

  14. Acoustic transducer

    DOEpatents

    Drumheller, Douglas S.

    2000-01-01

    An active acoustic transducer tool for use down-hole applications. The tool includes a single cylindrical mandrel including a shoulder defining the boundary of a narrowed portion over which is placed a sandwich-style piezoelectric tranducer assembly. The piezoelectric transducer assembly is prestressed by being placed in a thermal interference fit between the shoulder of the mandrel and the base of an anvil which is likewise positioned over the narrower portion of the mandrel. In the preferred embodiment, assembly of the tool is accomplished using a hydraulic jack to stretch the mandrel prior to emplacement of the cylindrical sandwich-style piezoelectric transducer assembly and anvil. After those elements are positioned and secured, the stretched mandrel is allowed to return substantially to its original (pre-stretch) dimensions with the result that the piezoelectric transducer elements are compressed between the anvil and the shoulder of the mandrel.

  15. Acoustic transducer

    DOEpatents

    Drumheller, D.S.

    1997-12-30

    An acoustic transducer is described comprising a one-piece hollow mandrel into the outer surface of which is formed a recess with sides perpendicular to the central axis of the mandrel and separated by a first distance and with a bottom parallel to the central axis and within which recess are a plurality of washer-shaped discs of a piezoelectric material and at least one disc of a temperature-compensating material with the discs being captured between the sides of the recess in a pre-stressed interference fit, typically at 2,000 psi of compressive stress. The transducer also includes a power supply and means to connect to a measurement device. The transducer is intended to be used for telemetry between a measurement device located downhole in an oil or gas well and the surface. The transducer is of an construction that is stronger with fewer joints that could leak fluids into the recess holding the piezoelectric elements than is found in previous acoustic transducers. 4 figs.

  16. Acoustic transducer

    DOEpatents

    Drumheller, Douglas S.

    1997-01-01

    An acoustic transducer comprising a one-piece hollow mandrel into the outer surface of which is formed a recess with sides perpendicular to the central axis of the mandrel and separated by a first distance and with a bottom parallel to the central axis and within which recess are a plurality of washer-shaped discs of a piezoelectric material and at least one disc of a temperature-compensating material with the discs being captured between the sides of the recess in a pre-stressed interference fit, typically at 2000 psi of compressive stress. The transducer also includes a power supply and means to connect to a measurement device. The transducer is intended to be used for telemetry between a measurement device located downhole in an oil or gas well and the surface. The transducer is of an construction that is stronger with fewer joints that could leak fluids into the recess holding the piezoelectric elements than is found in previous acoustic transducers.

  17. Ultrasonic transducer

    SciTech Connect

    Taylor, Steven C.; Kraft, Nancy C.

    2007-03-13

    An ultrasonic transducer having an effective center frequency of about 42 MHz; a bandwidth of greater than 85% at 6 dB; a spherical focus of at least 0.5 inches in water; an F4 lens; a resolution sufficient to be able to detect and separate a 0.005 inch flat-bottomed hole at 0.005 inches below surface; and a beam size of approximately 0.006–0.008 inches measured off a 11/2 mm ball in water at the transducer's focal point.

  18. Flexible ultrasonic transducers incorporating piezoelectric fibres.

    PubMed

    Harvey, Gerald; Gachagan, Anthony; Mackersie, John W; McCunnie, Thomas; Banks, Robert

    2009-09-01

    It is possible to produce a high-performance, flexible 1-3 connectivity piezoelectric ceramic composite with conventional methods but the process is difficult and time-consuming. Extensive finite element modeling was used to design a piezocomposite structure which incorporated randomly positioned piezoceramic fibers in a polymer matrix. Simple manufacturing techniques were developed which resulted in the production of large numbers of fully populated fiber composites that offered performance comparable with a conventional 1-3 piezocomposite. A modified process facilitated the production of efficient fiber piezocomposite elements separated by polymer channels which conformed to a highly flexible (13 mm radius of curvature), 2-D matrix array configuration. This arrangement has been termed a Composite Element Composite Array Transducer, or CECAT. These devices were evaluated in terms of their impedance spectra, pulse-echo response, and surface displacement characteristics. The random piezoceramic fiber arrangements showed comparable sensitivity and bandwidth to periodic devices while minimizing the parasitic interpillar modes associated with periodic structures. Investigations have indicated that CECAT arrays constructed with 250 microm diameter fibers can be operated at frequencies of up to 3 MHz and transducers incorporating 10 microm diameter fibers can extend the frequency range above 6 MHz. Conversely, improved low-frequency devices can be produced with taller pillars than possible with conventional manufacturing techniques. PMID:19812003

  19. High performance relaxor-based ferroelectric single crystals for ultrasonic transducer applications.

    PubMed

    Chen, Yan; Lam, Kwok-Ho; Zhou, Dan; Yue, Qingwen; Yu, Yanxiong; Wu, Jinchuan; Qiu, Weibao; Sun, Lei; Zhang, Chao; Luo, Haosu; Chan, Helen L W; Dai, Jiyan

    2014-01-01

    Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) have drawn much attention in the ferroelectric field because of their excellent piezoelectric properties and high electromechanical coupling coefficients (d33~2000 pC/N, kt~60%) near the morphotropic phase boundary (MPB). Ternary Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) single crystals also possess outstanding performance comparable with PMN-PT single crystals, but have higher phase transition temperatures (rhombohedral to tetragonal Trt, and tetragonal to cubic Tc) and larger coercive field Ec. Therefore, these relaxor-based single crystals have been extensively employed for ultrasonic transducer applications. In this paper, an overview of our work and perspectives on using PMN-PT and PIN-PMN-PT single crystals for ultrasonic transducer applications is presented. Various types of single-element ultrasonic transducers, including endoscopic transducers, intravascular transducers, high-frequency and high-temperature transducers fabricated using the PMN-PT and PIN-PMN-PT crystals and their 2-2 and 1-3 composites are reported. Besides, the fabrication and characterization of the array transducers, such as phased array, cylindrical shaped linear array, high-temperature linear array, radial endoscopic array, and annular array, are also addressed. PMID:25076222

  20. High Performance Relaxor-Based Ferroelectric Single Crystals for Ultrasonic Transducer Applications

    PubMed Central

    Chen, Yan; Lam, Kwok-Ho; Zhou, Dan; Yue, Qingwen; Yu, Yanxiong; Wu, Jinchuan; Qiu, Weibao; Sun, Lei; Zhang, Chao; Luo, Haosu; Chan, Helen L. W.; Dai, Jiyan

    2014-01-01

    Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) have drawn much attention in the ferroelectric field because of their excellent piezoelectric properties and high electromechanical coupling coefficients (d33∼2000 pC/N, kt∼60%) near the morphotropic phase boundary (MPB). Ternary Pb(In1/2Nb1/2)O3-Pb(Mg1/3Nb2/3)O3-PbTiO3 (PIN-PMN-PT) single crystals also possess outstanding performance comparable with PMN-PT single crystals, but have higher phase transition temperatures (rhombohedral to tetragonal Trt, and tetragonal to cubic Tc) and larger coercive field Ec. Therefore, these relaxor-based single crystals have been extensively employed for ultrasonic transducer applications. In this paper, an overview of our work and perspectives on using PMN-PT and PIN-PMN-PT single crystals for ultrasonic transducer applications is presented. Various types of single-element ultrasonic transducers, including endoscopic transducers, intravascular transducers, high-frequency and high-temperature transducers fabricated using the PMN-PT and PIN-PMN-PT crystals and their 2-2 and 1-3 composites are reported. Besides, the fabrication and characterization of the array transducers, such as phased array, cylindrical shaped linear array, high-temperature linear array, radial endoscopic array, and annular array, are also addressed. PMID:25076222

  1. Pressure transducer

    DOEpatents

    Anderson, Thomas T.; Roop, Conard J.; Schmidt, Kenneth J.; Gunchin, Elmer R.

    1989-01-01

    A pressure transducer suitable for use in high temperature environments includes two pairs of induction coils, each pair being bifilarly wound together, and each pair of coils connected as opposite arms of a four arm circuit; an electrically conductive target moveably positioned between the coil pairs and connected to a diaphragm such that deflection of the diaphragm causes axial movement of the target and an unbalance in the bridge output.

  2. PRESSURE TRANSDUCER

    DOEpatents

    Sander, H.H.

    1959-10-01

    A pressure or mechanical force transducer particularly adaptable to miniature telemetering systems is described. Basically the device consists of a transistor located within a magnetic field adapted to change in response to mechanical force. The conduction characteristics of the transistor in turn vary proportionally with changes in the magnetic flux across the transistor such that the output (either frequency of amplitude) of the transistor circuit is proportional to mechanical force or pressure.

  3. Pressure transducer

    DOEpatents

    Anderson, T.T.; Roop, C.J.; Schmidt, K.J.; Gunchin, E.R.

    1987-02-13

    A pressure transducer suitable for use in high temperature environments includes two pairs of induction coils, each pair being bifilarly wound together, and each pair of coils connected as opposite arms of a four arm circuit; an electrically conductive target moveably positioned between the coil pairs and connected to a diaphragm such that deflection of the diaphragm causes axial movement of the target and an unbalance in the bridge output. 7 figs.

  4. 1-3 piezocomposite SmartPanels

    NASA Astrophysics Data System (ADS)

    Fiore, Daniel; Gentilman, Richard L.; Pham-Nguyen, Hong; Serwatka, William J.; McGuire, Patrick T.; Near, Craig D.; Bowen, Leslie J.

    1997-05-01

    Piezocomposite SmartPanelsTM, consisting of 1-3 actuators and pressure sensors and net-shape-molded PZT accelerometers in a large area low profile panel, have been fabricated at Materials Systems Inc. and evaluated at the Naval Research Laboratory. Single layer and two-layer 100 X 100 mm SmartPanels have been tested for sensor sensitivities, actuator authority, surface displacement uniformity, and sensor-actuator coupling. Multilayer GRP circuits boards are used both as stiff faceplates and to provide electrical connections and ground planes. The SmartPanel technology has recently been scaled up to 250 X 250 mm devices. SmartPanels draw upon PZT (lead zirconate titanate) ceramic injection molding technology, which is used to produce cost-effective and robust 1-3 piezoelectric ceramic-polymer composite materials. The 1-3 materials are used extensively for SonoPanelTM transducers in a number of sensor and actuator applications. SonoPanels have been qualified for US Navy applications, based on successful completion of pressure and shock tests, and are currently being scaled up from 250 X 250 mm to 750 X 750 mm panels. Several applications for SmartPanels and SonoPanels are described, including conformable transducers, multielement arrays, pressure sensors, and velocity sensors.

  5. Multifunctional transducer

    NASA Technical Reports Server (NTRS)

    Feldstein, C.; Lewis, G. W.; Culler, V. H.; Merrbaum, S. (Inventor)

    1981-01-01

    Several parameters of a small region of a muscle tissue or other object, can be simultaneously measured using with minimal traumatizing or damage of the object, a trifunctional transducer which can determine the force applied by a muscle fiber, the displacement of the fiber, and the change in thickness of the fiber. The transducer has three legs with inner ends joined together and outer ends formed to piece the tissue and remain within it. Two of the legs are relatively stiff, to measure force applied by the tissue, and a third leg is relatively flexible to measure displacement of the tissue relative to one or both stiff legs, and with the three legs lying in a common plane so that the force and displacement measurements all relate to the same direction of muscle movements. A flexible loop is attached to one of the stiff legs to measure changes in muscle thickness, with the upper end of the loop fixed to the leg and the lower end of the loop bearing against the surface of the tissue and being free to slide on the leg.

  6. Passive wireless ultrasonic transducer systems

    NASA Astrophysics Data System (ADS)

    Zhong, C. H.; Croxford, A. J.; Wilcox, P. D.

    2014-02-01

    Inductive coupling and capacitive coupling both offer simple solutions to wirelessly probe ultrasonic transducers. This paper investigates the theory and feasibility of such system in the context of non-destructive evaluation (NDE) applications. Firstly, the physical principles and construction of an inductively coupled transducer system (ICTS) and a capacitively coupled transducer system (CCTS) are introduced. Then the development of a transmission line model with the measured impedance of a bonded piezoelectric ceramic disc representing a sensor attached to an arbitrary solid substrate for both systems is described. The models are validated experimentally. Several applications of CCTS are presented, such CCTS for the underwater and through-composite testing.

  7. Scaling up the Single Transducer Thickness-Independent Ultrasonic Imaging Method for Accurate Characterization of Microstructural Gradients in Monolithic and Composite Tubular Structures

    NASA Technical Reports Server (NTRS)

    Roth, Don J.; Carney, Dorothy V.; Baaklini, George Y.; Bodis, James R.; Rauser, Richard W.

    1998-01-01

    Ultrasonic velocity/time-of-flight imaging that uses back surface reflections to gauge volumetric material quality is highly suited for quantitative characterization of microstructural gradients including those due to pore fraction, density, fiber fraction, and chemical composition variations. However, a weakness of conventional pulse-echo ultrasonic velocity/time-of-flight imaging is that the image shows the effects of thickness as well as microstructural variations unless the part is uniformly thick. This limits this imaging method's usefulness in practical applications. Prior studies have described a pulse-echo time-of-flight-based ultrasonic imaging method that requires using a single transducer in combination with a reflector plate placed behind samples that eliminates the effect of thickness variation in the image. In those studies, this method was successful at isolating ultrasonic variations due to material microstructure in plate-like samples of silicon nitride, metal matrix composite, and polymer matrix composite. In this study, the method is engineered for inspection of more complex-shaped structures-those having (hollow) tubular/curved geometry. The experimental inspection technique and results are described as applied to (1) monolithic mullite ceramic and polymer matrix composite 'proof-of-concept' tubular structures that contain machined patches of various depths and (2) as-manufactured monolithic silicon nitride ceramic and silicon carbide/silicon carbide composite tubular structures that might be used in 'real world' applications.

  8. Suggested Procedures for Installing Strain Gauges on Langley Research Center Wind Tunnel Balances, Custom Force Measuring Transducers, Metallic and Composite Structural Test Articles

    NASA Technical Reports Server (NTRS)

    Moore, Thomas C., Sr.

    2004-01-01

    The character of force and strain measurement testing at LaRC is such that the types of strain gauge installations, the materials upon which the strain gauges are applied, and the test environments encountered, require many varied approaches. In 1997, a NASA Technical Memorandum (NASA TM 110327) was generated to provide the strain gauge application specialist with a listing of recommended procedures for strain gauging various transducers and test articles at LaRC. The technical memorandum offered here is an effort to keep the strain gauge user informed of new technological enhancements in strain-gauging methodology while preserving the strain-gauging guidelines set forth in the 1997 TM. This document provides detailed recommendations for strain gauging LaRC-designed balances and custom transducers, composite materials, cryogenic and high-temperature test articles, and selected non-typical or unique materials or test conditions. Additionally, one section offers details for installing Bragg-Grating type fiber-optic strain sensors for non-typical test scenarios.

  9. Energy Harvesting from Ambient Vibrations with Arbitrary In-Plane Motion Directions Using a Magnetostrictive/Piezoelectric Laminate Composite Transducer

    NASA Astrophysics Data System (ADS)

    Yang, Jin; Wen, Yumei; Li, Ping; Yue, Xihai; Yu, Qiangmo

    2014-07-01

    A magnetoelectric (ME) vibration energy harvester has been designed to scavenge sufficient energy from ambient vibration with arbitrary motion directions in a plane and over a range of frequencies. In the harvester, a circular-cross-section cantilever rod is adopted to extract the vibration energy due to its ability to host accelerations in arbitrary in-plane motion directions. The magnetic coupling between the magnet and the ME transducer results in nonlinear oscillation of the cantilever rod with increased frequency bandwidth. To achieve optimal vibration energy harvesting performance, the effects of the nonlinear vibration and the harvester parameters including the magnetic circuit and the separation distance on the electrical output and the␣working bandwidth are analyzed. The experimental results show that the harvester can scavenge vibration energy in arbitrary in-plane directions, exhibiting a bandwidth of 4.0 Hz and maximum power of 0.22 mW at acceleration of 0.6 g (with g = 9.8 m s-2).

  10. Transducer-Mounting Fixture

    NASA Technical Reports Server (NTRS)

    Spiegel, Kirk W.

    1990-01-01

    Transducer-mounting fixture holds transducer securely against stud. Projects only slightly beyond stud after installation. Flanged transducer fits into fixture when hinged halves open. When halves reclosed, fixture tightened onto threaded stud until stud makes contact with transducer. Knurled area on fixture aids in tightening fixture on stud.

  11. Piezoelectric materials used in underwater acoustic transducers

    SciTech Connect

    Li, Huidong; Deng, Zhiqun; Carlson, Thomas J.

    2012-07-07

    Piezoelectric materials have been used in underwater acoustic transducers for nearly a century. In this paper, we reviewed four different types of piezoelectric materials: piezoelectric ceramics, single crystals, composites, and polymers, which are widely used in underwater acoustic transducers nowadays. Piezoelectric ceramics are the most dominant material type and are used as a single-phase material or one of the end members in composites. Piezoelectric single crystals offer outstanding electromechanical response but are limited by their manufacturing cost. Piezoelectric polymers provide excellent acoustic impedance matching and transducer fabrication flexibility although their piezoelectric properties are not as good as ceramics and single crystals. Composites combined the merits of ceramics and polymers and are receiving increased attention. The typical structure and electromechanical properties of each type of materials are introduced and discussed with respect to underwater acoustic transducer applications. Their advantages and disadvantages are summarized. Some of the critical design considerations when developing underwater acoustic transducers with these materials are also touched upon.

  12. Assessing the relationship between the inter-rod coupling and the efficiency of piezocomposite high-intensity focused ultrasound transducers.

    PubMed

    Chen, Gin-Shin; Pan, Chia-Ching; Lin, Yu-Li; Cheng, Jung-Sung

    2014-03-01

    The electroacoustic conversion efficiency of the ultrasonic transducer is a critical performance index for high-power applications. The material properties, volume fraction (VF) and aspect ratio (AR) are typically regarded as the design parameters of the piezocomposite transducer. We hypothesized that the spacing between piezoelectric rods was also a dominant factor. Therefore, the inter-rod coupling effects on the efficiency of 1-3 piezocomposite ultrasonic transducers were investigated in this study. The efficiencies of six flat and three curved 1.0 MHz PZT4 epoxy composite transducers with different geometric parameters were measured. Finite element transient analyses of the inter-rod electrical-mechanical coupling in the composites were carried out to explain the measured results. The experimental results showed that for 0.47 AR, the 79% VF transducers had lower efficiency than the 64% VF and 53% VF transducers. For 0.19 AR, the efficiency of the 59% VF transducer was not greater than the efficiency of the 39% VF transducer. Numerical analyses demonstrated that the positive peak voltage induced by the coupling of the side rods was more than twice the level induced by the coupling of the diagonal rods for any spacing. The diagonal coupling voltage peak did not change for spacings larger than 0.2 mm. Moreover, for spacings of 0.05 and 0.1 mm, the inter-rod coupling caused 24% and 20% waveform shifts of the driving voltage, respectively, while the 0.2 mm spacing coupling caused a 14% reduction in the amplitude of the driving voltage. As a result, the asymmetry of the driving voltage degraded the efficiency of the composite transducers and became more severe when the spacing was decreased. We concluded that the efficiency loss induced by inter-rod coupling as a function of spacing should be considered when designing piezocomposite transducers. PMID:24269167

  13. Ultrasonic Transducer Irradiation Test Results

    SciTech Connect

    Daw, Joshua; Palmer, Joe; Ramuhalli, Pradeep; Keller, Paul; Montgomery, Robert; Chien, Hual-Te; Kohse, Gordon; Tittmann, Bernhard; Reinhardt, Brian; Rempe, Joy

    2015-02-01

    Ultrasonic technologies offer the potential for high-accuracy and -resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other ongoing efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. For this reason, the Pennsylvania State University (PSU) was awarded an ATR NSUF project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The goal of this research is to characterize and demonstrate magnetostrictive and piezoelectric transducer operation during irradiation, enabling the development of novel radiation-tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers. To date, one piezoelectric

  14. Creation of hierarchical carbon nanotube assemblies through alternative packing of complementary semi-artificial beta-1,3-glucan/carbon nanotube composites.

    PubMed

    Numata, Munenori; Sugikawa, Kouta; Kaneko, Kenji; Shinkai, Seiji

    2008-01-01

    Much attention has been focused on exploiting novel strategies for the creation of hierarchical polymer assemblies by the control of the assembling number or the relative location among neighboring polymers. We here propose a novel strategy toward the creation of "hierarchical" single-walled carbon nanotube (SWNT) architectures by utilizing SWNT composites with cationic or anionic complementary semi-artificial beta-1,3-glucans as "building blocks". These beta-1,3-glucans are known to wrap SWNTs helically, to create one-dimensional superstructural composites. If the cationic composite is neutralized by an anionic composite, a well ordered SWNT-based sheet structure was created. Transmission electron microscopy (TEM) observation revealed that this sheet structure is composed of highly-ordered fibrous assemblies of SWNTs. This suggests that the cationic and anionic composites are tightly packed through electrostatic interactions. Moreover, both of the final assembly structures are readily tunable by adjusting the cation/anion ratio. The self-assembling modulation of functional polymers is associated with the progress in ultimate nanotechnologies, thus enabling us to create numerous functional nanomaterials. We believe, therefore, that the present system will extend the frontier of SWNT research to assembly chemistry including "hierarchical" superstructures. PMID:18200640

  15. Dual-frequency super harmonic imaging piezoelectric transducers for transrectal ultrasound

    NASA Astrophysics Data System (ADS)

    Kim, Jinwook; Li, Sibo; Kasoji, Sandeep; Dayton, Paul A.; Jiang, Xiaoning

    2015-03-01

    In this paper, a 2/14 MHz dual-frequency single-element transducer and a 2/22 MHz sub-array (16/48-elements linear array) transducer were developed for contrast enhanced super-harmonic ultrasound imaging of prostate cancer with the low frequency ultrasound transducer as a transmitter for contrast agent (microbubble) excitation and the high frequency transducer as a receiver for detection of nonlinear responses from microbubbles. The 1-3 piezoelectric composite was used as active materials of the single-element transducers due to its low acoustic impedance and high coupling factor. A high dielectric constant PZT ceramic was used for the sub-array transducer due to its high dielectric property induced relatively low electrical impedance. The possible resonance modes of the active elements were estimated using finite element analysis (FEA). The pulse-echo response, peak-negative pressure and bubble response were tested, followed by in vitro contrast imaging tests using a graphite-gelatin tissue-mimicking phantom. The single-element dual frequency transducer (8 × 4 × 2 mm3) showed a -6 dB fractional bandwidth of 56.5% for the transmitter, and 41.8% for the receiver. A 2 MHz-transmitter (730 μm pitch and 6.5 mm elevation aperture) and a 22 MHz-receiver (240 μm pitch and 1.5 mm aperture) of the sub-array transducer exhibited -6 dB fractional bandwidth of 51.0% and 40.2%, respectively. The peak negative pressure at the far field was about -1.3 MPa with 200 Vpp, 1-cycle 2 MHz burst, which is high enough to excite microbubbles for nonlinear responses. The 7th harmonic responses from micro bubbles were successfully detected in the phantom imaging test showing a contrast-to-tissue ratio (CTR) of 16 dB.

  16. Compositional dependence of Pb(Mg1/3,Nb2/3)O3-PbTiO3 piezoelectric thin films by combinatorial sputtering

    NASA Astrophysics Data System (ADS)

    Kurokawa, Fumiya; Tsujiura, Yuichi; Hida, Hirotaka; Kanno, Isaku

    2014-09-01

    We evaluated the compositional dependence of Pb(Mg1/3,Nb2/3)O3-PbTiO3 (PMN-PT) polycrystalline thin films by combinatorial sputtering. We prepared compositional gradient (1 - x)PMN-xPT polycrystalline thin films with preferential orientation along the <001> direction in the composition range of x = 0-0.62. We determined that the morphotropic phase boundary (MPB) composition of PMN-PT polycrystalline thin film existed at around x = 0.35, from the X-ray diffraction (XRD) measurements. The maximum value of relative dielectric constants (ɛr = 1498) was obtained at approximately x = 0.23. On the other hand, the piezoelectric coefficients (|e31,f| = 14.1 C/m2) peaked at the determined MPB composition of x = 0.35. From the results of the compositional dependence of dielectric and piezoelectric characteristics, the FOM (e_{31,\\text{f}}^{2}/\\varepsilon _{0}\\varepsilon _{\\text{r}}) of the PMN-PT (x = 0.35) thin film reached 21 GPa, which is much higher than that of the other polycrystalline piezoelectric thin films. These results suggest that PMN-PT (x = 0.35) thin film is a promising material for high-efficiency piezoelectric MEMS energy harvesters.

  17. Optical measuring displacement transducers

    NASA Astrophysics Data System (ADS)

    Dich, L. Z.

    1994-09-01

    Trends in the development and production of photoelectric displacement transducers are analyzed. The technical characteristics of certain transducers are briefly presented. A table of comparisons is given, based on available information sources.

  18. Transducer applications, a compilation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The characteristics and applications of transducers are discussed. Subjects presented are: (1) thermal measurements, (2) liquid level and fluid flow measurements, (3) pressure transducers, (4) stress-strain measurements, (5) acceleration and velocity measurements, (6) displacement and angular rotation, and (7) transducer test and calibration methods.

  19. Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography

    NASA Astrophysics Data System (ADS)

    Ma, Jianguo; Martin, K. Heath; Li, Yang; Dayton, Paul A.; Shung, K. Kirk; Zhou, Qifa; Jiang, Xiaoning

    2015-05-01

    Imaging of coronary vasa vasorum may lead to assessment of the vulnerable plaque development in diagnosis of atherosclerosis diseases. Dual frequency transducers capable of detection of microbubble super-harmonics have shown promise as a new contrast-enhanced intravascular ultrasound (CE-IVUS) platform with the capability of vasa vasorum imaging. Contrast-to-tissue ratio (CTR) in CE-IVUS imaging can be closely associated with low frequency transmitter performance. In this paper, transducer designs encompassing different transducer layouts, transmitting frequencies, and transducer materials are compared for optimization of imaging performance. In the layout selection, the stacked configuration showed superior super-harmonic imaging compared with the interleaved configuration. In the transmitter frequency selection, a decrease in frequency from 6.5 MHz to 5 MHz resulted in an increase of CTR from 15 dB to 22 dB when receiving frequency was kept constant at 30 MHz. In the material selection, the dual frequency transducer with the lead magnesium niobate-lead titanate (PMN-PT) 1-3 composite transmitter yielded higher axial resolution compared to single crystal transmitters (70 μm compared to 150 μm pulse length). These comparisons provide guidelines for the design of intravascular acoustic angiography transducers.

  20. Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography.

    PubMed

    Ma, Jianguo; Martin, K Heath; Li, Yang; Dayton, Paul A; Shung, K Kirk; Zhou, Qifa; Jiang, Xiaoning

    2015-05-01

    Imaging of coronary vasa vasorum may lead to assessment of the vulnerable plaque development in diagnosis of atherosclerosis diseases. Dual frequency transducers capable of detection of microbubble super-harmonics have shown promise as a new contrast-enhanced intravascular ultrasound (CE-IVUS) platform with the capability of vasa vasorum imaging. Contrast-to-tissue ratio (CTR) in CE-IVUS imaging can be closely associated with low frequency transmitter performance. In this paper, transducer designs encompassing different transducer layouts, transmitting frequencies, and transducer materials are compared for optimization of imaging performance. In the layout selection, the stacked configuration showed superior super-harmonic imaging compared with the interleaved configuration. In the transmitter frequency selection, a decrease in frequency from 6.5 MHz to 5 MHz resulted in an increase of CTR from 15 dB to 22 dB when receiving frequency was kept constant at 30 MHz. In the material selection, the dual frequency transducer with the lead magnesium niobate-lead titanate (PMN-PT) 1-3 composite transmitter yielded higher axial resolution compared to single crystal transmitters (70 μm compared to 150 μm pulse length). These comparisons provide guidelines for the design of intravascular acoustic angiography transducers. PMID:25856384

  1. Design factors of intravascular dual frequency transducers for super-harmonic contrast imaging and acoustic angiography

    PubMed Central

    Ma, Jianguo; Martin, K. Heath; Li, Yang; Dayton, Paul A.; Shung, K. Kirk; Zhou, Qifa; Jiang, Xiaoning

    2015-01-01

    Imaging of coronary vasa vasorum may lead to assessment of the vulnerable plaque development in diagnosis of atherosclerosis diseases. Dual frequency transducers capable of detection of microbubble super-harmonics have shown promise as a new contrast-enhanced intravascular ultrasound (CE-IVUS) platform with the capability of vasa vasorum imaging. Contrast-to-tissue ratio (CTR) in CE-IVUS imaging can be closely associated with the low frequency transmitter performance. In this paper, transducer designs encompassing different transducer layouts, transmitting frequencies, and transducer materials are compared for optimization of imaging performance. In the layout selection, the stacked configuration showed superior super-harmonic imaging compared with the interleaved configuration. In the transmitter frequency selection, a decrease in frequency from 6.5 MHz to 5 MHz resulted in an increase of CTR from 15 dB to 22 dB when receiving frequency was kept constant at 30 MHz. In the material selection, the dual frequency transducer with the lead magnesium niobate-lead titanate (PMN-PT) 1-3 composite transmitter yielded higher axial resolution compared to single crystal transmitters (70 μm compared to 150 μm pulse length). These comparisons provide guidelines for design of intravascular acoustic angiography transducers. PMID:25856384

  2. Influence of TEM specimen preparation on chemical composition of Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystals.

    PubMed

    Srot, Vesna; Gec, Medeja; van Aken, Peter A; Jeon, Jae-Ho; Ceh, Miran

    2014-07-01

    The influences of different transmission electron microscopy (TEM) specimen preparation techniques on the chemical composition of Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) single crystals was studied. Ion-milled samples where no cooling with liquid nitrogen (L-N2) was applied show permanently changed composition also deep inside the bulk material. When the PMN-PT samples were cooled to L-N2 temperature during the ion-milling process and in addition lower accelerating voltages were used, the chemical composition was altered only in the thinnest parts close to the specimen edge. Samples prepared using only tripod polishing technique show compositional irregularities close to the specimen edge. For the preparation of lead-containing samples, such as PMN-PT single crystals, a combination of tripod polishing and short Ar-ion-milling at low accelerating voltages while cooling the samples to liquid nitrogen temperature proved to be the most suitable to obtain artefact-free electron-transparent TEM lamellae. PMID:24811990

  3. Irradiation Testing of Ultrasonic Transducers

    SciTech Connect

    Daw, Joshua; Tittmann, Bernhard; Reinhardt, Brian; Kohse, Gordon E.; Ramuhalli, Pradeep; Montgomery, Robert O.; Chien, Hual-Te; Villard, Jean-Francois; Palmer, Joe; Rempe, Joy

    2014-07-30

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. For this reason, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). The goal of this research is to characterize magnetostrictive and piezoelectric transducer survivability during irradiation, enabling the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). As such, this test will be an instrumented lead test and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers.

  4. Irradiation Testing of Ultrasonic Transducers

    SciTech Connect

    Daw, Joshua; Tittmann, Bernhard; Reinhardt, Brian; Kohse, Gordon E.; Ramuhalli, Pradeep; Montgomery, Robert O.; Chien, Hual-Te; Villard, Jean-Francois; Palmer, Joe; Rempe, Joy

    2013-12-01

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of single, small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models. Other efforts include an ultrasonic technique to detect morphology changes (such as crack initiation and growth) and acoustic techniques to evaluate fission gas composition and pressure. These efforts are limited by the lack of existing knowledge of ultrasonic transducer material survivability under irradiation conditions. For this reason, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate promising magnetostrictive and piezoelectric transducer performance in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2 (E> 0.1 MeV). The goal of this research is to characterize magnetostrictive and piezoelectric transducer survivability during irradiation, enabling the development of novel radiation tolerant ultrasonic sensors for use in Material and Test Reactors (MTRs). As such, this test will be an instrumented lead test and real-time transducer performance data will be collected along with temperature and neutron and gamma flux data. The current work bridges the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the performance of ultrasonic transducers.

  5. Elongation Transducer For Tensile Tests

    NASA Technical Reports Server (NTRS)

    Roberts, Paul W.; Stokes, Thomas R.

    1994-01-01

    Extensometer transducer measures elongation of tensile-test specimen with negligible distortion of test results. Used in stress-versus-strain tests of small specimens of composite materials. Clamping stress distributed more evenly. Specimen clamped gently between jaw and facing surface of housing. Friction force of load points on conical tips onto specimen depends on compression of spring, adjusted by turning cover on housing. Limp, light nylon-insulated electrical leads impose minimal extraneous loads on measuring elements.

  6. Phase insensitive acoustoelectric transducer

    NASA Technical Reports Server (NTRS)

    Heyman, J. S.

    1978-01-01

    Conventional ultrasonic transducers transform acoustic waves into electrical signals preserving phase and amplitude information. When the acoustic wavelength is significantly smaller than the transducer diameter, severe phase modulation of the electrical signal can occur. This results in anomalous attenuation measurements, background noise in nondestructive evaluation, and in general complicates data interpretation. This article describes and evaluates a phase-insensitive transducer based on the acoustoelectric effect. Theory of operation of the acoustoelectric transducer (AET) is discussed, and some optimization procedures outlined for its use. Directivity data for the AET are contrasted with a conventional piezoelectric transducer. In addition, transmission scanning data of phantom flaws in metal plates are presented for both transducers and demonstrate a significant improvement in resolution with the AET.

  7. Ultrasensitive ultrasonic transducer studies

    SciTech Connect

    Dixon, R.; Darling, T.; Migliori, A.

    1996-09-01

    This is the final report of a one-year, Laboratory-Directed Research and Development (LDRD) project at the Los Alamos National Laboratory (LANL). This project sought to continue development of the ultrasensitive ultrasonic transducers that won a 1994 R&D 100 Award. These transducers have a very smooth response across a broad frequency range and thus are extremely well- suited for resonant ultrasound spectroscopy as well as pulsed-echo and acoustic-emission applications. Current work on these transducers has indicated that bonding the piezoelectric and wear surface to a metal foil and attaching the foil to a body is less expensive and produces a transducer that is as good or better than commercially produced transducers. We have diffusion- bonded piezoelectric crystals and backings to stainless-steel-foil and wear surfaces. These are then attached onto stainless-steel tubes with electrical connectors to form the transducers. The transducers have been characterized using a reciprocity technique, electrical response, and optical interferometry. After characterization, the transducers have been compared to existing transducers by measuring and testing identical properties.

  8. Composition Dependence of Electrocaloric Effect in (1 - x)Pb(Mg1/3Nb2/3)O3 -xPbTiO3 Single Crystals

    NASA Astrophysics Data System (ADS)

    Qiu, Jian-Hua; Wang, Xiu-Qin; Yuan, Ning-Yi; Ding, Jian-Ning

    2015-07-01

    Composition dependence of electrocaloric effect is investigated in (1 - x)Pb(Mg1/3Nb2/3)O3 - xPbTiO3 single crystals by using an eighth-order Landau-Devonshire theory. The applied electric field along [001] direction reduces the ferroelectric-ferroelectric phase transition temperatures, but increases the Curie temperatures. The electrocaloric coefficients of tetragonal phase are much larger than that of rhombohedral and monoclinic phase. A negative electrocaloric effect is observed near the MC-T phase transition in 0.69Pb(Mg1/3Nb2/3)O3-0.31PbTiO3 single crystal. The application of a strong enough electric field results in a high adiabatic temperature change over a broad range of temperature. Therefore, it would be useful to construct a solid state cooling cycle over a broad temperature range for practical applications. Supported by the State Key Program of National Natural Science of China under Grant No. 51335002, Changzhou Science and Technology Project under Grant No. CJ20130022, and the Priority Academic Program Development of Jiangsu Higher Education Institutions on Renewable Energy Material Science and Engineering

  9. FABRICATION AND TESTING OF MICROWAVE SINTERED SOL-GEL SPRAY-ON BISMUTH TITANATE-LITHIUM NIOBATE BASED PIEZOELECTRIC COMPOSITE FOR USE AS A HIGH TEMPERATURE (>500 deg. C) ULTRASONIC TRANSDUCER

    SciTech Connect

    Searfass, C. T.; Baba, A.; Tittmann, B. R.; Agrawal, D. K.

    2010-02-22

    Bismuth titanate-lithium niobate based ultrasonic transducers have been fabricated using a sol-gel spray-on deposition technique. These transducers were then tested to determine their potential as high temperature ultrasonic transducers. Fabricated transducers were capable of operating to 1000 deg. C in pulse-echo mode; however, the exposure to such extreme temperatures appears to be destructive to the transducers.

  10. Advanced piezoelectric single crystal based transducers for naval sonar applications

    NASA Astrophysics Data System (ADS)

    Snook, Kevin A.; Rehrig, Paul W.; Hackenberger, Wesley S.; Jiang, Xiaoning; Meyer, Richard J., Jr.; Markley, Douglas

    2006-03-01

    Transducers incorporating single crystal piezoelectric Pb(Mg 1/3Nb 2/3) x-1Ti xO 3 (PMN-PT) exhibit significant advantages over ceramic piezoelectrics such as PZT, including both high electromechanical coupling (k 33 > 90%) and piezoelectric coefficients (d 33 > 2000 pC/N). Conventional <001> orientation gives inherently larger bandwidth and output power than PZT ceramics, however, the anisotropy of the crystal also allows for tailoring of the performance by orienting the crystal along different crystallographic axes. This attribute combined with composition refinements can be used to improve thermal or mechanical stability, which is important in high power, high duty cycle sonar applications. By utilizing the "31" resonance mode, the high power performance of PMN-PT can be improved over traditional "33" mode single crystal transducers, due to an improved aspect ratio. Utilizing novel geometries, effective piezoelectric constants of -600 pC/N to -1200 pC/N have been measured. The phase transition point induced by temperature, pre-stress or field is close to that in the "33" mode, and since the prestress is applied perpendicular to the poling direction in "31" mode elements, they exhibit lower loss and can therefore be driven harder. The high power characteristics of tonpilz transducers can also be affected by the composition of the PMN-PT crystal. TRS modified the composition of PMN-PT to improve the thermal stability of the material, while keeping the loss as low as possible. Three dimensional modeling shows that the useable bandwidth of these novel compositions nearly equals that of conventional PMN-PT. A decrease in the source level of up to 6 dB was calculated, which can be compensated for by the higher drive voltages possible.

  11. Deposition of antibacterial of poly(1,3-bis-(p-carboxyphenoxy propane)-co-(sebacic anhydride)) 20:80/gentamicin sulfate composite coatings by MAPLE

    NASA Astrophysics Data System (ADS)

    Cristescu, R.; Popescu, C.; Socol, G.; Visan, A.; Mihailescu, I. N.; Gittard, S. D.; Miller, P. R.; Martin, T. N.; Narayan, R. J.; Andronie, A.; Stamatin, I.; Chrisey, D. B.

    2011-04-01

    We report on thin film deposition of poly(1,3-bis-(p-carboxyphenoxy propane)-co-sebacic anhydride)) 20:80 thin films containing several gentamicin concentrations by matrix assisted pulsed laser evaporation (MAPLE). A pulsed KrF* excimer laser was used to deposit the polymer-drug composite thin films. Release of gentamicin from these MAPLE-deposited polymer conjugate structures was assessed. Fourier transform infrared spectroscopy was used to demonstrate that the functional groups of the MAPLE-transferred materials were not changed by the deposition process nor were new functional groups formed. Scanning electron microscopy confirmed that MAPLE may be used to fabricate thin films of good morphological quality. The activity of gentamicin-doped films against Escherichia coli and Staphylococcus aureus bacteria was demonstrated using disk diffusion and antibacterial drop test. Our studies indicate that deposition of polymer-drug composite thin films prepared by MAPLE is a suitable technique for performing controlled drug delivery. Antimicrobial thin film coatings have several medical applications, including use for indwelling catheters and implanted medical devices.

  12. Experiments with Ultrasonic Transducers.

    ERIC Educational Resources Information Center

    Greenslade, Thomas R., Jr.

    1994-01-01

    Discusses the use of 40 kHz ultrasonic transducers to study wave phenomena. Determines that the resulting wavelength of 9 mm allows acoustic experiments to be performed on a tabletop. Includes transducer characteristics and activities on speed of sound, reflection, double- and single-slit diffraction, standing waves, acoustical zone plate, and…

  13. Crossflow force transducer. [LMFBR

    SciTech Connect

    Mulcahy, T M

    1982-05-01

    A force transducer for measuring lift and drag coefficients for a circular cylinder in turbulent water flow is presented. In addition to describing the actual design and construction of the strain-gauged force- ring based transducer, requirements for obtained valid fluid force test data are discussed, and pertinent flow test experience is related.

  14. SonoPanel(TM) 1-3 Piezocomposite Panels for Active Surface Control

    NASA Technical Reports Server (NTRS)

    Gentilman, R.; Bowen, L.; Fiore, D.; Pham, H.; Serwatka, W.

    1996-01-01

    Materials Systems Inc. has developed a cost-effective technology for producing 1-3 piezoelectric ceramic/polymer composites for use in active surface control. MSI's 103 piezocomposite SonoPanel(TM) transducers consist of an array of piezoelectric ceramic rods arranged in a compliant polymer matrix. The standard SonoPanel(TM) composite consists of 15 volume percent PZT-5H rods 1.1 mm diameter x 6.3 mm long in a matrix of soft polyurethane. Stiff face plates are then bonded to the 1-3 composite sheet for stress amplification when used as a sensor and to enhance the surface response uniformity when used as an actuator. Many variations on this composite design have been produced for specific application requirements.

  15. Quantitative analysis of damage in an octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazonic-based composite explosive subjected to a linear thermal gradient

    SciTech Connect

    Peterson, Paul D.; Mang, Joseph T.; Asay, Blaine W.

    2005-05-01

    The microstructure within a slowly heated, consolidated explosive will be influenced by both physical changes and chemical reactions prior to thermal ignition. Thermal expansion, exothermic decomposition, endothermic phase change, and increased binder viscosity play significant roles in the cook-off to detonation. To further explore the details of this intricate cook-off process, we have conducted a series of experiments in which a carefully controlled temperature gradient has been applied along a cylinder of PBX 9501 [94.9/2.5/2.5/0.1-wt % octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX)/Estane 5703/a eutectic mixture of bis(2,2 dinitropropyl) acetal and bis(2,2-dinitropropyl) formal [abbreviated BDNPA-F]/Irganox] and maintained for a specified amount of time. After heating and subsequent cooling of the PBX 9501, the sample morphology has been probed with polarized light microscopy and small-angle x-ray scattering. Using these techniques we have quantitatively characterized the particle morphology, porosity, and chemical state of the explosive as a function of position, and therefore thermal treatment. Results of the analyses clearly show that thermal damage in PBX 9501 can be classified into two separate temperature regimes--an initial low-temperature regime (155-174 deg. C) dominated by the endothermic {beta}-{delta} crystalline phase change, thermal expansion, and Ostwald ripening, and a high-temperature regime (175-210 deg. C) dominated by exothermic chemical decomposition. The results further show the complex interplay between the evolving sample morphology and the chemical reactions leading to a potential thermal self-ignition in the explosive.

  16. Spark ultrasonic transducer

    NASA Technical Reports Server (NTRS)

    Hoop, J. M.

    1972-01-01

    Nondestructive testing by spark transducer induces ultrasonic pulses in materials without physical contact. High power pulse generator connected to step up transformer produces sparking between two tungsten rods and ultrasonic energy pulses in test samples placed between rods.

  17. Improved myocardium transducer

    NASA Technical Reports Server (NTRS)

    Culler, V. H.; Feldstein, C.; Lewis, G. W.

    1979-01-01

    Method of implanting myocardium transducer uses special indented pins that are caught and securely held by epicardial fibers. Pins are small enough to cause minimum of trauma to myocardium during implantation or removal.

  18. Composite interval mapping and mixed models reveal QTL associated with performance and carcass traits on chicken chromosomes 1, 3, and 4.

    PubMed

    Rosario, M F; Gazaffi, R; Moura, A S A M T; Ledur, M C; Coutinho, L L; Garcia, A A F

    2014-02-01

    Interval mapping (IM) implemented in QTL Express or GridQTL is widely used, but presents some limitations, such as restriction to a fixed model, risk of mapping two QTL when there may be only one and no discrimination of two or more QTL using both cofactors located on the same and other chromosomes. These limitations were overcome with composite interval mapping (CIM). We reported QTL associated with performance and carcass traits on chicken chromosomes 1, 3, and 4 through implementation of CIM and analysis of phenotypic data using mixed models. Thirty-four microsatellite markers were used to genotype 360 F2 chickens from crosses between males from a layer line and females from a broiler line. Sixteen QTL were mapped using CIM and 14 QTL with IM. Furthermore, of those 30 QTL, six were mapped only when CIM was used: for body weight at 35 days (first and third peaks on GGA4), body weight at 41 days (GGA1B and second peak on GGA4), and weights of back and legs (both on GGA4). Three new regions had evidence for QTL presence: one on GGA1B associated with feed intake 35-41 d at 404 cM (LEI0107-ADL0183) and two on GGA4 associated with weight of back at 163 cM (LEI0076-MCW0240) and weight gain 35-41 d, feed efficiency 35-41 d and weight of legs at 241 cM (LEI0085-MCW0174). We dissected one more linked QTL on GGA4, where three QTL for BW35 and two QTL for BW41 were mapped. Therefore, these new regions mapped here need further investigations using high-density SNP to confirm these QTL and identify candidate genes associated with those traits. PMID:24288072

  19. Determination of the compositional fluctuation in the perovskite ternary system PbZrO/sub 3/-PbTiO/sub 3/-Pb(Mg/sub 1/3/Ta/sub 2/3/)O/sub 3/

    SciTech Connect

    Kakegawa, K.; Kawakami, M.; Sasaki, Y.

    1988-10-01

    A method was developed for the determination of a region of compositional fluctuation in the perovskite ternary solid-solution system PbZrO/sub 3/-PbTiO/sub 3/-Pb(Mg/sub 1/3/Ta/sub 2/3/)O/sub 3/. The compositional fluctuation in the ternary system extends two-dimensionally on the phase diagram. The method described in this paper utilized the fact that the compositional fluctuation region abuts on the curves of composition whose lattice spacing is the lower or higher fluctuation limit. The fluctuation limits of the lattice spacing were estimated from X-ray diffraction analysis.

  20. Microfiber interferometric acoustic transducers.

    PubMed

    Wang, Xiuxin; Jin, Long; Li, Jie; Ran, Yang; Guan, Bai-Ou

    2014-04-01

    Acoustic and ultrasonic transducers are key components in biomedical information technology, which has been applied in medical diagnosis, photoacoustic endoscopy and photoacoustic imaging. In this paper, an acoustic transducer based on Fabry-Perot interferometer (FPI) fabricated in a microscaled optical fiber is demonstrated. The transducer is fabricated by forming two wavelength-matched Bragg gratings into the microfiber by means of side illumination with a 193nm excimer laser. When placing the transducer in water, the applied acoustic signal periodically changes the refractive index (RI) of the surrounding liquid and modulates the transmission of the FPI based on the evanescent-field interaction between the liquid and the transmitting light. As a result, the acoustic signal can be constructed with a tunable laser whose output wavelength is located at the slope of the inteferometric fringes. The transducer presents a sensitivity of 10 times higher than the counterparts fabricated in conventional singlemode fibers and has great potential to achieve higher resolution for photoacoustic imaging due to its reduced diameter. PMID:24718189

  1. Miniature biaxial strain transducer

    NASA Technical Reports Server (NTRS)

    Hoffman, I. S. (Inventor)

    1976-01-01

    A reusable miniature strain transducer for use in the measurement of static or quasi-static, high level, biaxial strain on the surface of test specimens or structures was studied. Two cantilever arms, constructed by machining the material to appropriate flexibility, are self-aligning and constitute the transducing elements of the device. Used in conjunction with strain gages, the device enables testing beyond normal gage limits for high strains and number of load cycles. The device does not require conversion computations since the electrical output of the strain gages is directly proportional to the strain measured.

  2. Broadband Ultrasonic Transducers

    NASA Technical Reports Server (NTRS)

    Heyser, R. C.

    1986-01-01

    New geometry spreads out resonance region of piezoelectric crystal. In new transducer, crystal surfaces made nonparallel. One surface planar; other, concave. Geometry designed to produce nearly uniform response over a predetermined band of frequencies and to attenuate strongly frequencies outside band. Greater bandwidth improves accuracy of sonar and ultrasonic imaging equipment.

  3. Ultrasonic Transducer Analyzer

    NASA Technical Reports Server (NTRS)

    Grounds, M. K.

    1982-01-01

    Ultrasonic transducer-beam-intensity distributions are determined by analyzing echoes from a spherical ball. Computers control equipment and process data. Important beam characteristics, such as location of best beam focus and beam diameter at focus, can be determined quickly from extensive set of plots generated by apparatus.

  4. Inertia diaphragm pressure transducer

    NASA Technical Reports Server (NTRS)

    Seegmiller, H. L. B.

    1971-01-01

    Transducer measures gas pressure profiles in high temperature, short duration, gas flows usually found in devices where pressure pulses may have durations of few microseconds to several milliseconds. Assembly includes fluid delay line, delay chamber, and flow restrictor for equalizing steady state pressure on diaphragm's sides

  5. Acoustooptic pulse-echo transducer system

    NASA Technical Reports Server (NTRS)

    Claus, R. O.; Wade, J. C.

    1983-01-01

    A pulse-echo transducer system which uses an ultrasonic generating element and an optical detection technique is described. The transmitting transducer consists of a concentric ring electrode pattern deposited on a circular, X-cut quartz substrate with a circular hole in the center. The rings are independently pulsed with a sequence high voltage signals phased in such a way that the ultrasonic waves generated by the separate rings superimpose to produce a composite field which is focused at a controllable distance below the surface of the specimen. The amplitude of the field reflected from this focus position is determined by the local reflection coefficient of the medium at the effective focal point. By processing the signals received for a range of ultrasonic transducer array focal lengths, the system can be used to locate and size anomalies within solids and liquids. Applications in both nondestructive evaluation and biomedical scanning are suggested.

  6. Ultrasonic comb transducer for smart materials

    NASA Astrophysics Data System (ADS)

    Rose, J. L.

    1998-04-01

    Installation of a small multi-element comb type ultrasonic transducer is proposed as a component of a smart structure. It can be used in either an active or passive mode in carrying out ultrasonic bulk or guided wave nondestructive evaluation. Theoretical methods are developed and experimental results are presented for guided wave generation and mode control with this very efficient and versatile novel comb type ultrasonic transducer. Excitation and probe design is crucial in mode selection. The comb transducer generates waves that are influenced by such parameters as number of elements, spacing between elements, dimension, pulsing sequence, and pressure distribution. The excited elastic field depends on the excitation frequency, plate thickness, and elastic properties. Techniques are studied to optimize the applied loading and the comb transducer design parameters so that only modes that are most sensitive to particular material characteristics can be generated. Complete understanding of the comb transducer parameters and their impact on the elastic field allows us to efficiently generate higher order modes as well as low phase velocity modes which are valuable in composite material characterization. Sample experiments are presented for various plate and tube like structures.

  7. Advanced piezoelectric single crystal based transducers for naval sonar applications

    NASA Astrophysics Data System (ADS)

    Snook, Kevin A.; Rehrig, Paul W.; Hackenberger, Wesley S.; Jiang, Xiaoning; Meyer, Richard J., Jr.; Markley, Douglas

    2005-05-01

    TRS is developing new transducers based on single crystal piezoelectric materials such as Pb(Mg1/3Nb2/3)x-1TixO3 (PMN-PT). Single crystal piezoelectrics such as PMN-PT exhibit very high piezoelectric coefficients (d33 ~ 1800 to >2000 pC/N) and electromechanical coupling factors (k33 > 0.9), respectively, which may be exploited for improving the performance of broad bandwidth and high frequency sonar. Apart from basic performance, much research has been done on reducing the size and increasing the output power of tonpilz transducers for sonar applications. Results are presented from two different studies. "33" mode single crystal tonpilz transducers have reduced stack lengths due to their low elastic stiffness relative to PZTs, however, this produces non-ideal aspect ratios due to large lateral dimensions. Alternative "31" resonance mode tonpilz elements are proposed to improve performance over these "33" designs. d32 values as high as 1600 pC/N have been observed, and since prestress is applied perpendicular to the poling direction, "31" mode Tonpilz elements exhibit lower loss and higher reliability than "33" mode designs. Planar high power tonpilz arrays are the optimum way to obtain the required acoustic pressure and bandwidth for small footprint, high power sensors. An important issue for these sensors is temperature and prestress stability, since fluctuations in tonpilz properties affects power delivery and sensing electronic design. TRS used the approach of modifying the composition of PMN-PT to improve the temperature dependence of properties of the material. Results show up to a 50% decrease in temperature change while losing minimal source level.

  8. Future needs for biomedical transducers

    NASA Technical Reports Server (NTRS)

    Wooten, F. T.

    1971-01-01

    In summary there are three major classes of transducer improvements required: improvements in existing transducers, needs for unexploited physical science phenomena in transducer design, and needs for unutilized physiological phenomena in transducer design. During the next decade, increasing emphasis will be placed on noninvasive measurement in all of these areas. Patient safety, patient comfort, and the need for efficient utilization of the time of both patient and physician requires that noninvasive methods of monitoring be developed.

  9. Design and fabrication of a flexible large area fabric transducer for bone healing application

    NASA Astrophysics Data System (ADS)

    Jadidian, Bahram

    The electromechanical transducers have found applications in their either passive or active modes. These applications include hydrophone, medical imaging, nondestructive evaluation, motors, sensors, actuators, civil and aerospace engineering. Other medical applications for ultrasonic transducers include therapeutics, osteosynthesis, lithotripsy, thrombolysis, and transdermal drug administration. During the past few decades, lead zirconate titanate (PZT), has been utilized in transducer applications in the form of a bulk piezoelectric ceramic and/or ceramic-polymer composites because of its high piezoelectric charge coefficient d33. The usage of piezoelectric ceramic/polymer composites allows designers to overcome some of the problems dealing with either monolithic piezoceramics or piezopolymers in transducer applications. In this work, a variety of composites with different connectivity patterns were formed. Composites with 1-3 connectivity were fabricated using bundling and collimating methods. Sized and unsized fibers were woven to form fabric. The fabric was used to form 3-3 composites and spiral structures. Square sheets of the fabric were laminated on top of each other, heat treated, and embedded in different types of polymer. The effect of applied pressure on the stack during heat treatment was studied. Plane fabric was formed in the spiral manner and used to construct piezocomposites. A piezoelectric transducer with high thickness coupling coefficient and its matching layer were exploited for bone healing application. One of the structures with the highest electromechanical properties, developed in this work, was chosen for the array fabrication. The spiral composite elements, with the best properties, were arranged in a 3 x 4 format embedded in a flexible polymer. The mechanical endurance of the elements and the array was studied. A large area flexible matching layer with low attenuation was developed. An extensive study was performed to determine the

  10. Influence of backing and matching layers in ultrasound transducer performance

    NASA Astrophysics Data System (ADS)

    do Nascimento, Valeria M.; Nantes Button, Vera L. d. S.; Maia, Joaquim M.; Costa, Eduardo T.; Oliveira, Eduardo J. V.

    2003-05-01

    In this work we have investigated the influence of the backing layer composition and the matching layer thickness in the performance of ultrasound transducers constructed with piezoelectric ceramic disks. We have constructed transducers with backing layers of different compositions, using mixtures of epoxy with alumina powder and/or Tungsten powder and with λ/4 or 3λ/4 thickness epoxy matching layers. The evaluation tests were performed in pulse-echo mode, with a flat target, and in transmission/reception mode, with a calibrated PVDF hydrophone. The acoustical field emitted by each transducer was mapped in order to measure the on-axis and transverse field profiles, the aperture size and the beam spreading. The bandwidths of the transducers were determined in pulse-echo mode. Comparing the evaluation tests results of two transducers constructed with the same backing layer, the one constructed with λ/4 thickness epoxy matching layer showed better performance. The results showed that the transducers constructed with epoxy, alumina and Tungsten powders backing layers have larger bandwidth. The larger depth of field was measured for transducers constructed with epoxy and Tungsten powder backing layers. These transducers and those constructed with epoxy, Tungsten and alumina powders backing layers showed the larger field intensities in the measured transverse profiles.

  11. Three dimensional transducer

    SciTech Connect

    Warren, Oden Lee; Asif, Syed Amanulla Syed; Oh, Yunje; Feng, Yuxin; Cyrankowski, Edward; Major, Ryan

    2014-09-30

    A testing instrument for mechanical testing at nano or micron scale includes a transducer body, and a coupling shaft coupled with a probe tip. A transducer body houses a capacitor. The capacitor includes first and second counter electrodes and a center electrode assembly interposed therebetween. The center electrode assembly is movable with the coupling shaft relative to the first and second counter electrodes, for instance in one or more of dimensions including laterally and normally. The center electrode assembly includes a center plate coupled with the coupling shaft and one or more springs extending from the center plate. Upper and lower plates are coupled with the center plate and cover the center plate and the one or more springs. A shaft support assembly includes one or more support elements coupled along the coupling shaft. The shaft support assembly provides lateral support to the coupling shaft.

  12. Nano-optomechanical transducer

    DOEpatents

    Rakich, Peter T; El-Kady, Ihab F; Olsson, Roy H; Su, Mehmet Fatih; Reinke, Charles; Camacho, Ryan; Wang, Zheng; Davids, Paul

    2013-12-03

    A nano-optomechanical transducer provides ultrabroadband coherent optomechanical transduction based on Mach-wave emission that uses enhanced photon-phonon coupling efficiencies by low impedance effective phononic medium, both electrostriction and radiation pressure to boost and tailor optomechanical forces, and highly dispersive electromagnetic modes that amplify both electrostriction and radiation pressure. The optomechanical transducer provides a large operating bandwidth and high efficiency while simultaneously having a small size and minimal power consumption, enabling a host of transformative phonon and signal processing capabilities. These capabilities include optomechanical transduction via pulsed phonon emission and up-conversion, broadband stimulated phonon emission and amplification, picosecond pulsed phonon lasers, broadband phononic modulators, and ultrahigh bandwidth true time delay and signal processing technologies.

  13. Stress wave focusing transducers

    SciTech Connect

    Visuri, S.R., LLNL

    1998-05-15

    Conversion of laser radiation to mechanical energy is the fundamental process behind many medical laser procedures, particularly those involving tissue destruction and removal. Stress waves can be generated with laser radiation in several ways: creation of a plasma and subsequent launch of a shock wave, thermoelastic expansion of the target tissue, vapor bubble collapse, and ablation recoil. Thermoelastic generation of stress waves generally requires short laser pulse durations and high energy density. Thermoelastic stress waves can be formed when the laser pulse duration is shorter than the acoustic transit time of the material: {tau}{sub c} = d/c{sub s} where d = absorption depth or spot diameter, whichever is smaller, and c{sub s} = sound speed in the material. The stress wave due to thermoelastic expansion travels at the sound speed (approximately 1500 m/s in tissue) and leaves the site of irradiation well before subsequent thermal events can be initiated. These stress waves, often evolving into shock waves, can be used to disrupt tissue. Shock waves are used in ophthalmology to perform intraocular microsurgery and photodisruptive procedures as well as in lithotripsy to fragment stones. We have explored a variety of transducers that can efficiently convert optical to mechanical energy. One such class of transducers allows a shock wave to be focused within a material such that the stress magnitude can be greatly increased compared to conventional geometries. Some transducer tips could be made to operate regardless of the absorption properties of the ambient media. The size and nature of the devices enable easy delivery, potentially minimally-invasive procedures, and precise tissue- targeting while limiting thermal loading. The transducer tips may have applications in lithotripsy, ophthalmology, drug delivery, and cardiology.

  14. Horizontal geophone transducer assembly

    SciTech Connect

    Hefer, F.W.

    1985-06-25

    The geophone transducer comprises in combination: a geophone capable of detecting horizontal seismic waves, and a rigid casing having a gimbal chamber. A gimbal is provided inside the chamber on which the geophone is mounted for limited free angular movement in one direction only. The gimbal includes in one preferred embodiment a viscous liquid in which the geophone is only partially submerged while it is supported by a U-shaped bracket which is mounted for rotation about a fixed axis.

  15. Fluid force transducer

    DOEpatents

    Jendrzejczyk, Joseph A.

    1982-01-01

    An electrical fluid force transducer for measuring the magnitude and direction of fluid forces caused by lateral fluid flow, includes a movable sleeve which is deflectable in response to the movement of fluid, and a rod fixed to the sleeve to translate forces applied to the sleeve to strain gauges attached to the rod, the strain gauges being connected in a bridge circuit arrangement enabling generation of a signal output indicative of the magnitude and direction of the force applied to the sleeve.

  16. Study on dielectric and piezoelectric properties of 0.7 Pb(Mg1/3Nb2/3)O3-0.3 PbTiO3 single crystal with nano-patterned composite electrode

    PubMed Central

    Chang, Wei-Yi; Huang, Wenbin; Bagal, Abhijeet; Chang, Chih-Hao; Tian, Jian; Han, Pengdi; Jiang, Xiaoning

    2013-01-01

    Effect of nano-patterned composite electrode and backswitching poling technique on dielectric and piezoelectric properties of 0.7 Pb(Mg1/3Nb2/3)O3-0.3 PbTiO3 was studied in this paper. Composite electrode consists of Mn nano-patterns with pitch size of 200 nm, and a blanket layer of Ti/Au was fabricated using a nanolithography based lift-off process, heat treatment, and metal film sputtering. Composite electrode and backswitching poling resulted in 27% increase of d33 and 25% increase of dielectric constant, and we believe that this is attributed to regularly defined nano-domains and irreversible rhombohedral to monoclinic phase transition in crystal. The results indicate that nano-patterned composite electrode and backswitching poling has a great potential in domain engineering of relaxor single crystals for advanced devices. PMID:24170960

  17. Hydrostatic piezoelectric properties of [011] poled Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystals and 2-2 lamellar composites.

    PubMed

    Li, Lili; Zhang, Shujun; Xu, Zhuo; Geng, Xuecang; Wen, Fei; Luo, Jun; Shrout, Thomas R

    2014-01-20

    The hydrostatic piezoelectric properties of [011] poled Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) crystals and corresponding 2-2 crystal/epoxy composites were investigated. The crystal volume ratio and compositional dependencies of the hydrostatic charge and voltage coefficients (dh and gh ) and hydrostatic figure of merit (FOM) dh  × gh were determined, where large FOM value of 3.2 pm(2)/N with high stability as a function of hydrostatic pressure was achieved for rhombohedral crystal composites. In addition, the stress amplification effects of the face-plate and different epoxy matrixes were investigated, with maximum FOM value being on the order of 92 pm(2)/N, indicating that 2-2 crystal/epoxy composites are promising materials for hydrostatic applications. PMID:24753619

  18. Poly[dithio-2,5-(1,3,4-thiadiazole)] (PDMcT)-poly(3,4-ethylenedioxythiophene) (PEDOT) composite cathode for high-energy lithium/lithium-ion rechargeable batteries

    NASA Astrophysics Data System (ADS)

    Kiya, Yasuyuki; Iwata, Asao; Sarukawa, Tomoo; Henderson, Jay C.; Abruña, Héctor D.

    We present a characterization of the redox behavior of organosulfur-based composite cathodes composed of poly[dithio-2,5-(1,3,4-thiadiazole)] (PDMcT), which is a polymer derived from 2,5-dimercapto-1,3,4-thiadiazole (DMcT), and poly(3,4-ethylenedioxythiophene) (PEDOT) in a carbonate-based mixed solvent containing 1.0 M LiBF 4. We have previously shown that PEDOT films, electrochemically generated at glassy carbon electrode surfaces, gave rise to a dramatic enhancement of the interfacial charge transfer kinetics of DMcT in solution. In a similar fashion, chemically prepared PEDOT films exhibited dramatic electrocatalytic activity towards the redox reactions of PDMcT in the composite cathodes. While the composite cathode exhibited a very high capacity of 205 mAh g -1 (based on the electroactive mass) at the first discharge, in subsequent charge/discharge tests, the capacity of the PDMcT-PEDOT composite cathode (1:1 mole ratio) decreased significantly because of dissolution of the reduction products of PDMcT into the electrolyte solution. We also found that an ionic polymer, consisting of a mixture of PEDOT and polystyrene sulfonate (PEDOT-PSS) could electrostatically, but not physically, prevent, at least in part, leaching of the DMcT species into the electrolyte solution, thus improving the coulomb efficiency for the redox reactions of DMcT in a PDMcT-PEDOT composite film during charge/discharge cycles.

  19. Transducers for ultrasonic limb plethysmography

    NASA Technical Reports Server (NTRS)

    Nickell, W. T.; Wu, V. C.; Bhagat, P. K.

    1983-01-01

    The design, construction, and performance characteristics of ultasonic transducers suitable for limb plethysmography are presented. Both 3-mm-diameter flat-plate and 12-mm-diameter hemispheric ceramic transducers operating at 2 MHz were fitted in 1-mm thick epoxy-resin lens/acoustic-coupling structures and mounted in exercie-EKG electrode housings for placement on the calf using adhesive collars. The effects of transducer directional characteristics on performance under off-axis rotation and the electrical impedances of the transducers were measured: The flat transducer was found to be sensitive to rotation and have an impedance of 800 ohms; the hemispheric transducer, to be unaffected by rotation and have an impedance of 80 ohms. The use of hemispheric transducers as both transmitter and receiver, or of a flat transducer as transmitter and a hemispheric transducer as receiver, was found to produce adequate dimensional measurements, with minimum care in transducer placement, in short-term physiological experiments and long-term (up to 7-day) attachment tests.

  20. An electromechanical displacement transducer

    NASA Astrophysics Data System (ADS)

    Villiers, Marius; Mahboob, Imran; Nishiguchi, Katsuhiko; Hatanaka, Daiki; Fujiwara, Akira; Yamaguchi, Hiroshi

    2016-08-01

    Two modes of an electromechanical resonator are coupled through the strain inside the structure with a cooperativity as high as 107, a state-of-the-art value for purely mechanical systems, which enables the observation of normal-mode splitting. This coupling is exploited to transduce the resonator’s fundamental mode into the bandwidth of the second flexural mode, which is 1.4 MHz higher in frequency. Thus, an all-mechanical heterodyne detection scheme is implemented that can be developed into a high-precision displacement sensor.

  1. Improved Micromachined Transducers

    NASA Technical Reports Server (NTRS)

    Hartley, Frank T.; Wise, James H.

    1994-01-01

    Sensor systems of proposed type incorporate micromachined silicon-based structures as electrostatic force and displacement actuators and micromachined quantum-mechanical-tunneling electrodes as one form of displacement transducers, along with electronic circuits providing multiple electrical stimuli to displacement electrodes for measurement, calibration, monitoring of sensor status, and adjustment. Concept applicable to accelerometers, seismometers, geophones, magnetometers, pressure gauges, and other sensors in which phenomena of interest measured in terms of forces on, and/or displacements of, structural components. Provides completely remote measurement, control, health monitoring, treatment, and like, using telemetry commands.

  2. Thin film strain transducer

    NASA Technical Reports Server (NTRS)

    Rand, J. L. (Inventor)

    1984-01-01

    A strain transducer system and process for making the same is disclosed. A beryllium copper ring having four strain gages is electrically connected in Wheatstone bridge fashion to the output instrumentation. Tabs are bonded to a balloon or like surface with strain on the surface causing bending of a ring which provides an electrical signal through the gages proportional to the surface strain. A photographic pattern of a one half ring segment as placed on a sheet of beryllium copper for chem-mill etch formation is illustrated.

  3. Wellbore pressure transducer

    DOEpatents

    Shuck, Lowell Z.

    1979-01-01

    Subterranean earth formations containing energy values are subjected to hydraulic fracturing procedures to enhance the recovery of the energy values. These fractures are induced in the earth formation by pumping liquid into the wellbore penetrating the earth formation until the pressure of the liquid is sufficient to fracture the earth formation adjacent to the wellbore. The present invention is directed to a transducer which is positionable within the wellbore to generate a signal indicative of the fracture initiation useful for providing a timing signal to equipment for seismic mapping of the fracture as it occurs and for providing a measurement of the pressure at which the fracture is initiated.

  4. RADIO-ACTIVE TRANSDUCER

    DOEpatents

    Wanetick, S.

    1962-03-01

    ABS>ure the change in velocity of a moving object. The transducer includes a radioactive source having a collimated beam of radioactive particles, a shield which can block the passage of the radioactive beam, and a scintillation detector to measure the number of radioactive particles in the beam which are not blocked by the shield. The shield is operatively placed across the radioactive beam so that any motion normal to the beam will cause the shield to move in the opposite direction thereby allowing more radioactive particles to reach the detector. The number of particles detected indicates the acceleration. (AEC)

  5. Transducer of linear displacements

    NASA Astrophysics Data System (ADS)

    Malamed, Y. R.

    1984-02-01

    The basic PLP transducer is designed for a UIM-29 microscope and a 2-coordinate measuring instrument with electronic digital readout. Its optical system consists of an AL-107B light-emitting diode as light source, two condenser lenses, a special wedge carrying two pairs of joined receiver lenses, a prism-mirror, a photoreceiver, a wedge-shape transparent replica of a twin diffraction grating which prevents light reflected by the air-glass interface from focusing on the receiver photodiodes, and a reflective replica of a diffraction grating on a movable carriage. The already available three models of this transducer are PLP1-0.2, PLP1-0.5, and PLP1-1.0 with respectively 625, 250, 125 lines/mm on the transparent replica and respectively 312.5, 125, 62.5 lines/mm on the reflective replica. The scale of moire-interference fringes characterizing the shift between both diffraction gratings per grating period (9.16 mm in each model) is respectively 0.8, 2.0, 4.0 microns and the angle between the two arrays of grating lines on the transparent replica is respectively 36 + or - 4 deg, 90 + or - 10 deg, 190 + or - 20 deg.

  6. Improved Piezoelectric Loudspeakers And Transducers

    NASA Technical Reports Server (NTRS)

    Regan, Curtis Randall; Jalink, Antony; Hellbaum, Richard F.; Rohrbach, Wayne W.

    1995-01-01

    Loudspeakers and related acoustic transducers of improved type feature both light weight and energy efficiency of piezoelectric transducers and mechanical coupling efficiency. Active component of transducer made from wafer of "rainbow" piezoelectric material, ceramic piezoelectric material chemically reduced on one face. Chemical treatment forms wafer into dishlike shallow section of sphere. Both faces then coated with electrically conductive surface layers serving as electrodes. Applications include high-fidelity loudspeakers, and underwater echo ranging devices.

  7. Switching of the photonic band gap in three-dimensional film photonic crystals based on opal-VO{sub 2} composites in the 1.3-1.6 {mu}m spectral range

    SciTech Connect

    Pevtsov, A. B. Grudinkin, S. A.; Poddubny, A. N.; Kaplan, S. F.; Kurdyukov, D. A.; Golubev, V. G.

    2010-12-15

    The parameters of three-dimensional photonic crystals based on opal-VO{sub 2} composite films in the 1.3-1.6 {mu}m spectral range important for practical applications (Telecom standard) are numerically calculated. For opal pores, the range of filling factors is established (0.25-0.6) wherein the composite exhibits the properties of a three-dimensional insulator photonic crystal. On the basis of the opal-VO{sub 2} composites, three-dimensional photonic film crystals are synthesized with specified parameters that provide a maximum shift of the photonic band gap in the vicinity of the wavelength {approx}1.5 {mu}m ({approx}170 meV) at the semiconductor-metal transition in VO{sub 2}.

  8. Parallel multilayer magnetoelectric composite based on (1-x)Pb(Mg1/3Nb2/3)-xPbTiO3 and Terfenol-D coupled with charge mode amplifier

    NASA Astrophysics Data System (ADS)

    Jiao, Jie; Li, Lingying; Ren, Bo; Guo, Hao; Deng, Hao; Di, Wenning; Zhao, Xiangyong; Jing, Weiping; Luo, Haosu

    2012-02-01

    In this paper, the sources and categories of noise regarding a charge mode magnetoelectric (ME) sensor are analyzed and simulated. A series of parallel multilayer magnetoelectric composites of Terfenol-D and (1-x)Pb(Mg1/3Nb2/3)-xPbTiO3 with different numbers of layers have been developed. The high magnetoelectric charge coefficients of these composites have been measured. By coupling different parallel multilayer magnetoelectric composites with a low noise-level charge amplifier, we found that the noise equivalent magnetic induction (NEB) of the ME sensor based on the charge mode is in accordance with the theoretical prediction, and multilayers can reduce the NEB at low frequency and hardly at high frequency. At last we have established a new method of using high g31 piezoelectric material that can effectively reduce the influence of the operational amplifier voltage noise component and enhance resolution.

  9. Ultrasonic Transducers for Fourier Analysis.

    ERIC Educational Resources Information Center

    Greenslade, Thomas B., Jr.

    1995-01-01

    Describes an experiment that uses the ultrasonic transducer for demonstrating the Fourier components of waveshapes such as the square and triangular waves produced by laboratory function generators. (JRH)

  10. Miniature multimode monolithic flextensional transducers.

    PubMed

    Hladky-Hennion, Anne-Christine; Uzgur, A Erman; Markley, Douglas C; Safari, Ahmad; Cochran, Joe K; Newnham, Robert E

    2007-10-01

    Traditional flextensional transducers classified in seven groups based on their designs have been used extensively in 1-100 kHz range for mine hunting, fish finding, oil explorations, and biomedical applications. In this study, a new family of small, low cost underwater, and biomedical transducers has been developed. After the fabrication of transducers, finite-elements analysis (FEA) was used extensively in order to optimize these miniature versions of high-power, low-frequency flextensional transducer designs to achieve broad bandwidth for both transmitting and receiving, engineered vibration modes, and optimized acoustic directivity patterns. Transducer topologies with various shapes, cross sections, and symmetries can be fabricated through high-volume, low-cost ceramic and metal extrusion processes. Miniaturized transducers posses resonance frequencies in the range of above 1 MHz to below 10 kHz. Symmetry and design of the transducer, polling patterns, driving and receiving electrode geometries, and driving conditions have a strong effect on the vibration modes, resonance frequencies, and radiation patterns. This paper is devoted to small, multimode flextensional transducers with active shells, which combine the advantages of small size and low-cost manufacturing with control of the shape of the acoustic radiation/receive pattern. The performance of the transducers is emphasized. PMID:18019236

  11. System for calibrating pressure transducer

    NASA Technical Reports Server (NTRS)

    Rollins, G. N. (Inventor)

    1973-01-01

    A system for calibrating a pressure transducer which has a reference portion and an active portion is reported. A miniature selector valve is positioned immediately adjacent the pressure transducer. A reference pressure, known pressure, and unknown pressure can be selectively admitted to the active side of the pressure transducer by the selector valve to enable calibration of the transducer. A valve admits pressure to the selector valve which has a piston and floating piston arrangement which allows proper selection with very small linear movement.

  12. A study of interface-sustained ferromagnetism in 1/2(1-x)Ln2O3-xSrO/1/3Co3O4 nano-composite.

    PubMed

    Tay, Siok Wei; Hong, Liang; Liu, Zhaolin

    2007-02-15

    The binary oxide composite, consisting of rock salt-type SrO and spinel Co3O4 nano-domains, exhibits soft ferromagnetic properties at ambient temperature. This ferromagnetism is originated from interface-induction, and the magnitude of the magnetic properties can be enhanced when the spinel phase of the composite is doped by a small amount of Ln2O3 (Ln = La, Nd, for instance). In this work, we study the composites of tri-oxide, 1/2(1-x)Ln2O3-xSrO/1/3Co3O4, where 0.01 < or =1-x < or = 0.6, by focusing on three areas: (i) generation of nano-composite dominant by interfacial phase via the pyrolysis of preceramic metallo-organic gel; (ii) influence of post-pyrolysis calcination and Ln2O3 content on the phase composition of the composite; and (iii) elucidation of different magnetic responses caused by the nature of Ln2O3 dissolved in the Co3O4 phase. The Ln(3+)-doped Co3O4 oxide displays only paramagnetic behavior at room temperature, but the ferromagnetic response is attained upon its mixing with SrO in nano-scale. The SrO phase plays the role in assisting Co3O4 phase with aligning unpaired electrons through interfacial induction. PMID:17126355

  13. Electromagnetic acoustic transducer

    DOEpatents

    Alers, George A.; Burns, Jr., Leigh R.; MacLauchlan, Daniel T.

    1988-01-01

    A noncontact ultrasonic transducer for studying the acoustic properties of a metal workpiece includes a generally planar magnetizing coil positioned above the surface of the workpiece, and a generally planar eddy current coil between the magnetizing coil and the workpiece. When a large current is passed through the magnetizing coil, a large magnetic field is applied to the near-surface regions of the workpiece. The eddy current coil can then be operated as a transmitter by passing an alternating current therethrough to excite ultrasonic waves in the surface of the workpiece, or operated as a passive receiver to sense ultrasonic waves in the surface by measuring the output signal. The geometries of the two coils can be varied widely to be effective for different types of ultrasonic waves. The coils are preferably packaged in a housing which does not interfere with their operation, but protects them from a variety of adverse environmental conditions.

  14. Optically transduced MEMS magnetometer

    SciTech Connect

    Nielson, Gregory N; Langlois, Eric

    2014-03-18

    MEMS magnetometers with optically transduced resonator displacement are described herein. Improved sensitivity, crosstalk reduction, and extended dynamic range may be achieved with devices including a deflectable resonator suspended from the support, a first grating extending from the support and disposed over the resonator, a pair of drive electrodes to drive an alternating current through the resonator, and a second grating in the resonator overlapping the first grating to form a multi-layer grating having apertures that vary dimensionally in response to deflection occurring as the resonator mechanically resonates in a plane parallel to the first grating in the presence of a magnetic field as a function of the Lorentz force resulting from the alternating current. A plurality of such multi-layer gratings may be disposed across a length of the resonator to provide greater dynamic range and/or accommodate fabrication tolerances.

  15. An opening electromagnetic transducer

    NASA Astrophysics Data System (ADS)

    Sun, Yanhua; Kang, Yihua

    2013-12-01

    Tubular solenoids have been widely used without any change since an electrical wire was discovered to create magnetic fields by Hans Christian Oersted in 1820 and thereby the wire was first coiled as a helix into a solenoid coil by William Sturgeon in 1823 and was improved by Joseph Henry in 1829 [see http://www.myetymology.com/encyclopedia/History_of_the_electricity.html; J. M. D. Coey, Magnetism and Magnetic Materials (Cambridge University Press, New York, 2010); and F. Winterberg, Plasma Phys. 8, 541553 (1996)]. A magnetic control method of C-shaped carrying-current wire is proposed, and thereby a new opening electromagnetic transducer evidently differing from the traditional tubular solenoid is created, capable of directly encircling and centering the acted objects in it, bringing about convenient and innovative electromagnetic energy conversion for electromagnetic heating, electromagnetic excitation, physical information capture, and electro-mechanical motion used in science research, industry, and even biomedical activities.

  16. Transverse Mode Multi-Resonant Single Crystal Transducer

    NASA Technical Reports Server (NTRS)

    Snook, Kevin A. (Inventor); Liang, Yu (Inventor); Luo, Jun (Inventor); Hackenberger, Wesley S. (Inventor); Sahul, Raffi (Inventor)

    2015-01-01

    A transducer is disclosed that includes a multiply resonant composite, the composite having a resonator bar of a piezoelectric single crystal configured in a d(sub 32) transverse length-extensional resonance mode having a crystallographic orientation set such that the thickness axis is in the (110) family and resonance direction is the (001) family.

  17. The double K+/Ca2+ sensor based on laser scanned silicon transducer (LSST) for multi-component analysis.

    PubMed

    Ermolenko, Yu; Yoshinobu, T; Mourzina, Yu; Furuichi, K; Levichev, S; Schöning, M J; Vlasov, Yu; Iwasaki, H

    2003-03-10

    In the present work a double ion sensor based on a laser scanned semiconductor transducer (LSST) for the simultaneous determination of K(+)- and Ca(2+)-ions in solutions has been developed. Specially elaborated ion-sensitive membrane compositions based on valinomycin and calcium ionophore calcium bis[4-(1,1,3,3-tetramethylbutyl)phenyl] phosphate (t-HDOPP-Ca) were deposited as separate layers on a silanized surface of the Si/SiO(2)/Si(3)N(4)-transducer. The proposed multi-sensor exhibits theoretical sensitivities and the detection limits of the sensor were found to be 2 x 10(-6) mol l(-1) for K(+) and 5 x 10(-6) mol l(-1) for Ca(2+). The elaborated double sensor is proposed for the first time as a prototype of a new type of multi-sensor systems for chemical analysis. PMID:18968966

  18. Adjustable holder for transducer mounting

    NASA Technical Reports Server (NTRS)

    Deotsch, R. C.

    1980-01-01

    Positioning of acoustic sensor, strain gage, or similar transducer is facilitated by adjustable holder. Developed for installation on Space Shuttle, it includes springs for maintaining uniform load on transducer with adjustable threaded cap for precisely controlling position of sensor with respect to surrounding structure.

  19. 1,3-Dichlorobenzene

    Integrated Risk Information System (IRIS)

    1,3 - Dichlorobenzene ; CASRN 541 - 73 - 1 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinog

  20. 1,3-Dichloropropene

    Integrated Risk Information System (IRIS)

    1,3 - Dichloropropene ( DCP ) ; CASRN 542 - 75 - 6 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Non

  1. 1,3-Butadiene

    Integrated Risk Information System (IRIS)

    1,3 - Butadiene ; CASRN 106 - 99 - 0 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcinogenic E

  2. Visualization and simulation of a linear explosive-induced pyroshock wave using Q-switched laser and phased array transducers in a space launcher composite structure

    NASA Astrophysics Data System (ADS)

    Lee, Jung-Ryul; Jang, Jae-Kyeong; Choi, Mijin; Kong, Cheol-Won

    2015-04-01

    During space flights, pyrotechnic devices are used for various purposes such as separation of boosters, satellites, fairings, and stages. In particular, the prediction of high shock structural response induced by linear explosives is important for safe operation of pyrotechnic devices. In general, repetitive explosive testing using distributed accelerometers is widely used, but multiple test structures are usually necessary because they are easily damaged and not reusable. This paper pertains to a nondestructive technology to replace the damage-causing, time-consuming, expensive, dangerous, and low-repeatability explosive test with a laser-induced shock test. The method proposed in this paper predicts nondestructively the linear explosive-induced pyroshock wave, visualizes its propagation, and allows the simulation of some detonation conditions. A ballistic test based on a linear explosive and noncontact laser Doppler vibrometer (LDV) as well as a nondestructive pyroshock test using laser-induced shock and PZT array sensors is performed in a 12.68-mm thick composite sandwich panel. The optimal laser-induced shock experimental conditions to predict real pyroshock response spectra (SRSs) are investigated by controlling the optical characteristics of the laser beam and adjusting the frequency bands in signal acquisition. The similarity of the SRS of the conditioned laser-induced shock to that of the real explosive pyroshock is evaluated with the mean acceleration difference. Next, the experimentally-determined optimal conditions are applied to arbitrary points in the laser-induced shock scanning area. Finally, it is shown that the proposed method will allow nondestructive and quantitative pyroshock testing, pyroshock wave propagation visualization showing the direction and magnitude of principal wave propagation, and detonation speed simulation depending on explosive type and detonation initiation point and direction.

  3. Circuit for Driving Piezoelectric Transducers

    NASA Technical Reports Server (NTRS)

    Randall, David P.; Chapsky, Jacob

    2009-01-01

    The figure schematically depicts an oscillator circuit for driving a piezoelectric transducer to excite vibrations in a mechanical structure. The circuit was designed and built to satisfy application-specific requirements to drive a selected one of 16 such transducers at a regulated amplitude and frequency chosen to optimize the amount of work performed by the transducer and to compensate for both (1) temporal variations of the resonance frequency and damping time of each transducer and (2) initially unknown differences among the resonance frequencies and damping times of different transducers. In other words, the circuit is designed to adjust itself to optimize the performance of whichever transducer is selected at any given time. The basic design concept may be adaptable to other applications that involve the use of piezoelectric transducers in ultrasonic cleaners and other apparatuses in which high-frequency mechanical drives are utilized. This circuit includes three resistor-capacitor networks that, together with the selected piezoelectric transducer, constitute a band-pass filter having a peak response at a frequency of about 2 kHz, which is approximately the resonance frequency of the piezoelectric transducers. Gain for generating oscillations is provided by a power hybrid operational amplifier (U1). A junction field-effect transistor (Q1) in combination with a resistor (R4) is used as a voltage-variable resistor to control the magnitude of the oscillation. The voltage-variable resistor is part of a feedback control loop: Part of the output of the oscillator is rectified and filtered for use as a slow negative feedback to the gate of Q1 to keep the output amplitude constant. The response of this control loop is much slower than 2 kHz and, therefore, does not introduce significant distortion of the oscillator output, which is a fairly clean sine wave. The positive AC feedback needed to sustain oscillations is derived from sampling the current through the

  4. Micromachined silicon seismic transducers

    SciTech Connect

    Barron, C.C.; Fleming, J.G.; Sniegowski, J.J.; Armour, D.L.; Fleming, R.P.

    1995-08-01

    Batch-fabricated silicon seismic transducers could revolutionize the discipline of CTBT monitoring by providing inexpensive, easily depolyable sensor arrays. Although our goal is to fabricate seismic sensors that provide the same performance level as the current state-of-the-art ``macro`` systems, if necessary one could deploy a larger number of these small sensors at closer proximity to the location being monitored in order to compensate for lower performance. We have chosen a modified pendulum design and are manufacturing prototypes in two different silicon micromachining fabrication technologies. The first set of prototypes, fabricated in our advanced surface- micromachining technology, are currently being packaged for testing in servo circuits -- we anticipate that these devices, which have masses in the 1--10 {mu}g range, will resolve sub-mG signals. Concurrently, we are developing a novel ``mold`` micromachining technology that promises to make proof masses in the 1--10 mg range possible -- our calculations indicate that devices made in this new technology will resolve down to at least sub-{mu}G signals, and may even approach to 10{sup {minus}10} G/{radical}Hz acceleration levels found in the low-earth-noise model.

  5. Piezoelectric transducer design for a miniaturized injectable acoustic transmitter

    NASA Astrophysics Data System (ADS)

    Li, H.; Jung, K. W.; Deng, Z. D.

    2015-11-01

    Implantable acoustic transmitters have been used in the last 20 years to track fish movement for fish survival and migration behavior studies. However, the relatively large weights and sizes of commercial transmitters limit the populations of studied fish. The surgical implantation procedures may also affect fish adversely and incur a significant amount of labor. Therefore, a smaller, lighter, and injectable transmitter was needed, and similar or better acoustic performance and service life over those provided by existing commercial transmitters was desired. To develop such a small transmitter, a number of technical challenges, including design optimization of the piezoelectric transducer, needed to be overcome. Our efforts to optimize the transducer focused on improving the average source level in the 180° range in which the signal was not blocked by the transmitter body. We found that a novel off-center tube transducer improved the average source level by 1.5 dB. An acoustic reflector attached to the back of the transducer also improved the source level by 1.3 dB. We found that too small a gap between the transducer and the component placed behind it resulted in distortion of the beam pattern. Lastly, a tuning inductor in series with the transducer was used to help optimize the source level. The findings and techniques developed in this work contributed to the successful development and implementation of a new injectable transmitter.

  6. Arterial pulse wave pressure transducer

    NASA Technical Reports Server (NTRS)

    Kim, C.; Gorelick, D.; Chen, W. (Inventor)

    1974-01-01

    An arterial pulse wave pressure transducer is introduced. The transducer is comprised of a fluid filled cavity having a flexible membrane disposed over the cavity and adapted to be placed on the skin over an artery. An arterial pulse wave creates pressure pulses in the fluid which are transduced, by a pressure sensitive transistor in direct contact with the fluid, into an electric signal. The electrical signal is representative of the pulse waves and can be recorded so as to monitor changes in the elasticity of the arterial walls.

  7. Fixture for holding testing transducer

    DOEpatents

    Wagner, T.A.; Engel, H.P.

    A fixture for mounting an ultrasonic transducer against the end of a threaded bolt or stud to test the same for flaws. A base means threadedly secured to the side of the bolt has a rotating ring thereon. A post rising up from the ring (parallel to the axis of the workpiece) pivotally mounts a variable length cross arm, on the inner end of which is mounted the transducer. A spring means acts between the cross arm and the base to apply the testing transducer against the workpiece at a constant pressure. The device maintains constant for successive tests the radial and circumferential positions of the testing transducer and its contact pressure against the end of the workpiece.

  8. Fixture for holding testing transducer

    DOEpatents

    Wagner, Thomas A.; Engel, Herbert P.

    1984-01-01

    A fixture for mounting an ultrasonic transducer against the end of a threaded bolt or stud to test the same for flaws. A base means threadedly secured to the side of the bolt has a rotating ring thereon. A post rising up from the ring (parallel to the axis of the workpiece) pivotally mounts a variable length cross arm, on the inner end of which is mounted the transducer. A spring means acts between the cross arm and the base to apply the testing transducer against the workpiece at a constant pressure. The device maintains constant for successive tests the radial and circumferential positions of the testing transducer and its contact pressure against the end of the workpiece.

  9. An enzyme logic bioprotonic transducer

    SciTech Connect

    Miyake, Takeo; Keene, Scott; Deng, Yingxin; Rolandi, Marco; Josberger, Erik E.

    2015-01-01

    Translating ionic currents into measureable electronic signals is essential for the integration of bioelectronic devices with biological systems. We demonstrate the use of a Pd/PdH{sub x} electrode as a bioprotonic transducer that connects H{sup +} currents in solution into an electronic signal. This transducer exploits the reversible formation of PdH{sub x} in solution according to PdH↔Pd + H{sup +} + e{sup −}, and the dependence of this formation on solution pH and applied potential. We integrate the protonic transducer with glucose dehydrogenase as an enzymatic AND gate for glucose and NAD{sup +}. PdH{sub x} formation and associated electronic current monitors the output drop in pH, thus transducing a biological function into a measurable electronic output.

  10. An enzyme logic bioprotonic transducer

    NASA Astrophysics Data System (ADS)

    Miyake, Takeo; Josberger, Erik E.; Keene, Scott; Deng, Yingxin; Rolandi, Marco

    2015-01-01

    Translating ionic currents into measureable electronic signals is essential for the integration of bioelectronic devices with biological systems. We demonstrate the use of a Pd/PdHx electrode as a bioprotonic transducer that connects H+ currents in solution into an electronic signal. This transducer exploits the reversible formation of PdHx in solution according to PdH↔Pd + H+ + e-, and the dependence of this formation on solution pH and applied potential. We integrate the protonic transducer with glucose dehydrogenase as an enzymatic and gate for glucose and NAD+. PdHx formation and associated electronic current monitors the output drop in pH, thus transducing a biological function into a measurable electronic output.

  11. Development of piezoelectric skin friction force vector transducer for a hypersonic wind tunnel

    NASA Technical Reports Server (NTRS)

    Kahng, S. K.

    1972-01-01

    A surface shear force transducer for use in impulse type hypersonic tunnels is described. Sensors are constructed of lead zirconate titanate composition piezoelectric ceramic materials. The diameter of the sensing diaphragm is 0.75 inches and overall transducer dimensions are 1.0 inch diameter and 0.625 inch height. Analysis of the tranducer is made to help design criteria and fabrication techniques. Discussions on design and fabrication techniques are presented as well as performance of transducers delivered.

  12. Acoustic transducer with damping means

    DOEpatents

    Smith, Richard W.; Adamson, Gerald E.

    1976-11-02

    An ultrasonic transducer specifically suited to high temperature sodium applications is described. A piezoelectric active element is joined to the transducer faceplate by coating the faceplate and juxtaposed active element face with wetting agents specifically compatible with the bonding procedure employed to achieve the joint. The opposite face of the active element is fitted with a backing member designed to assure continued electrical continuity during adverse operating conditions which can result in the fracturing of the active element. The fit is achieved employing a spring-loaded electrode operably arranged to electrically couple the internal transducer components, enclosed in a hermetically sealed housing, to accessory components normally employed in transducer applications. Two alternative backing members are taught for assuring electrical continuity. The first employs a resilient, discrete multipoint contact electrode in electrical communication with the active element face. The second employs a resilient, elastomeric, electrically conductive, damped member in electrical communication with the active element face in a manner to effect ring-down of the transducer. Each embodiment provides continued electrical continuity within the transducer in the event the active element fractures, while the second provides the added benefit of damping.

  13. Integrated transducer for color distinction

    NASA Astrophysics Data System (ADS)

    Kato, Hisao; Kojima, Masahiko; Yoshida, Akira

    1983-06-01

    A method for fabricating the improved version of an integrated transducer for color distinction is proposed. It consists of three SnO2(n)-Si(n) photodiodes on a Si wafer and a trichromatic filter prepared by arranging filters of the three primary colors (Eastman Kodak gelatin filters; Nos. 47B, 58, and 25) on an infrared glass filter (Hoya Glass; B-460). Its photoelectric characteristics and dependence of error of color distinction on the dimension of the transducer are reported. The photodiodes employed in this conversion assembly are produced by the simple spray method and are most suitable for detecting the low illumination. Since this transducer adapts the trichromatic color resolution method, highly accurate color distinction is possible. With this type of transducer, three photodiodes sensitive to the primary colors, red, green, and blue, respectively, are arranged on a plane. An error in color distinction can occur due to the differences in the strength of the light incident upon the respective photodiodes. This problem is reduced by making the transducer more compact. Finally, 11 kinds of colors are discerned in this experiment as an application of the transducer.

  14. Focusing of ferroelectret air-coupled ultrasound transducers

    NASA Astrophysics Data System (ADS)

    Gaal, Mate; Bartusch, Jürgen; Dohse, Elmar; Schadow, Florian; Köppe, Enrico

    2016-02-01

    Air-coupled ultrasound has been applied increasingly as a non-destructive testing method for lightweight construction in recent years. It is particularly appropriate for composite materials being used in automotive and aviation industry. Air-coupled ultrasound transducers mostly consist of piezoelectric materials and matching layers. However, their fabrication is challenging and their signal-to-noise ratio often not sufficient for many testing requirements. To enhance the efficiency, air-coupled ultrasound transducers made of cellular polypropylene have been developed. Because of its small density and sound velocity, this piezoelectric ferroelectret matches the small acoustic impedance of air much better than matching layers applied in conventional transducers. In our contribution, we present two different methods of spherical focusing of ferroelectret transducers for the further enhancement of their performance in NDT applications. Measurements on carbon-fiber-reinforced polymer (CFRP) samples and on metal adhesive joints performed with commercially available focused air-coupled ultrasound transducers are compared to measurements executed with self-developed focused ferroelectret transducers.

  15. High sensitivity gravimetric sensor made of carbon fiber epoxy composite on Pb(Mg1/3Nb2/3)O3-PbTiO3 single crystal substrate

    NASA Astrophysics Data System (ADS)

    Huang, Naixing; Lü, Tianquan; Zhang, Rui; Cao, Wenwu

    2013-07-01

    We have derived a general formula for sensitivity optimization of gravimetric sensors and use it to design a high sensitivity gravimetric sensor using unidirectional carbon fiber epoxy composite (CFEC) guiding layer on (1-x)Pb(Mg1/3Nb2/3)O3-xPbTiO3 (PMN-xPT) single crystal substrate. The normalized maximum sensitivity (|Smf|λ)max exhibits an increasing tendency with the decrease of (h/λ)opt. For the CFEC/[011]c poled PMN-0.29PT sensor configuration with λ = 24 μm, the maximum sensitivity |Smf|max can reach as high as 1230 cm2/g, which is about 3 times that of a traditional SiO2/ST quartz configuration gravimetric sensor.

  16. High intensity ultrasound transducer used in gene transfection

    NASA Astrophysics Data System (ADS)

    Morrison, Kyle P.; Keilman, George W.; Noble, Misty L.; Brayman, Andrew A.; Miao, Carol H.

    2012-11-01

    This paper describes a novel therapeutic high intensity non-focused ultrasound (HIU) transducer designed with uniform pressure distribution to aid in accelerated gene transfer in large animal liver tissues in vivo. The underlying HIU transducer was used to initiate homogeneous cavitation throughout the tissue while delivering up to 2.7 MPa at 1.1 MHz across its radiating surface. The HIU transducer was built into a 6 cm diameter x 1.3 cm tall housing ergonomically designed to avoid collateral damage to the surrounding anatomy during dynamic motion. The ultrasound (US) radiation was applied in a 'paintbrush-like' manner to the surface of the liver. The layers and geometry of the transducer were carefully selected to maximize the active diameter (5.74 cm), maximize the electrical to acoustic conversion efficiency (85%) to achieve 2.7 MPa of peak negative pressure, maximize the frequency operating band at the fundamental resonance to within a power transfer delta of 1 dB, and reduce the pressure delta to within 2 dB across the radiating surface. For maximum peak voltage into the transducer, a high performance piezoceramic was chosen and a DC bias circuit was built integral to the system. An apodized two element annular pattern was made from a single piezoceramic element, resulting in significant pressure uniformity enhancement. In addition to using apodization for pressure uniformity, a proprietary multi-layered structure was used to improve efficiency while sustaining an operating band from 900 kHz to 1.3 MHz. The resultant operating band allowed for dithering techniques using frequency modulation. The underlying HIU transducer for use in large animals enhances gene expression up to 6300-fold.

  17. Auto-positioning ultrasonic transducer system

    NASA Technical Reports Server (NTRS)

    Buchanan, Randy K. (Inventor)

    2010-01-01

    An ultrasonic transducer apparatus and process for determining the optimal transducer position for flow measurement along a conduit outer surface. The apparatus includes a transmitting transducer for transmitting an ultrasonic signal, said transducer affixed to a conduit outer surface; a guide rail attached to a receiving transducer for guiding movement of a receiving transducer along the conduit outer surface, wherein the receiving transducer receives an ultrasonic signal from the transmitting transducer and sends a signal to a data acquisition system; and a motor for moving the receiving transducer along the guide rail, wherein the motor is controlled by a controller. The method includes affixing a transmitting transducer to an outer surface of a conduit; moving a receiving transducer on the conduit outer surface, wherein the receiving transducer is moved along a guide rail by a motor; transmitting an ultrasonic signal from the transmitting transducer that is received by the receiving transducer; communicating the signal received by the receiving transducer to a data acquisition and control system; and repeating the moving, transmitting, and communicating along a length of the conduit.

  18. Novice performance of ultrasound-guided needle advancement: standard 38-mm transducer vs 25-mm hockey stick transducer.

    PubMed

    Davies, T; Townsley, P; Jlala, H; Dowling, M; Bedforth, N; Hardman, J G; McCahon, R A

    2012-08-01

    The optimal method to develop expertise in ultrasound-guided regional anaesthesia is unknown. Studies of laryngoscopic expertise in novices demonstrate that the choice of laryngoscope affects performance. In this study, we aimed to compare the effect of two different linear array transducers (38-mm standard vs 25-mm hockey stick) on novice performance of ultrasound-guided needle advancement. Following randomisation, participants watched a video model of expert performance of ultrasound-guided needle advancement. Recruits performed the modelled task on a turkey breast model. The median (IQR [range]) composite error score was statistically significantly larger for participants in the hockey stick transducer group compared with the standard transducer group; 10.0 (7.3-14.3 [2.5-29.0]) vs 7.5 (4.5-10.0 [2.0-28.0]) respectively, (p = 0.01). This study has demonstrated that performance of ultrasound-guided needle advancement by novice operators after simple video instruction is better (as assessed using a composite error score) with a standard 38-mm transducer than with a 25-mm hockey stick transducer. PMID:22506607

  19. Model of a Piezoelectric Transducer

    NASA Technical Reports Server (NTRS)

    Goodenow, Debra

    2004-01-01

    It's difficult to control liquid and gas in propellant tanks in zero gravity. A possible a design would utilize acoustic liquid manipulation (ALM) technology which uses ultrasonic beams conducted through a liquid and solid media, to push gas bubbles in the liquid to desirable locations. We can propel and control the bubble with acoustic radiation pressure by aiming the acoustic waves on the bubble s surface. This allows us to design a so called smart tank in which the ALM devices transfer the gas to the outer wall of the tank and isolating the liquid in the center. Because the heat transfer rate of a gas is lower of that of the liquid it would substantially decrease boil off and provide of for a longer storage life. The ALM beam is composed of little wavelets which are individual waves that constructively interfere with each other to produce a single, combined acoustic wave front. This is accomplished by using a set of synchronized ultrasound transducers arranged in an array. A slight phase offset of these elements allows us to focus and steer the beam. The device that we are using to produce the acoustic beam is called the piezoelectric transducer. This device converts electrical energy to mechanical energy, which appears in the form of acoustic energy. Therefore the behavior of the device is dependent on both the mechanical characteristics, such as its density, cross-sectional area, and its electrical characteristics, such as, electric flux permittivity and coupling factor. These devices can also be set up in a number of modes which are determined by the way the piezoelectric device is arranged, and the shape of the transducer. For this application we are using the longitudinal or thickness mode for our operation. The transducer also vibrates in the lateral mode, and one of the goals of my project is to decrease the amount of energy lost to the lateral mode. To model the behavior of the transducers I will be using Pspice, electric circuit modeling tool, to

  20. Rugged Direct-Current Transducer

    NASA Technical Reports Server (NTRS)

    Mclyman, W. T.

    1991-01-01

    Direct-current transducer withstands thermal and mechanical shocks. Operates from single, nominally 15-V power supply and nearly insensitive to both large variations in temperature and variations of as much as plus or minus 5 V in supply voltage. Its output voltage highly linear function of sensed current, with full-scale value of about 3 Vdc and offset of about 0.1 Vdc at 0 sensed current. Ruggedness of transducer due in large part to novel magnetic core, machined from solid block of nickel/iron high-permeability, low-hysteresis alloy.

  1. Environmental control system transducer development study

    NASA Technical Reports Server (NTRS)

    Brudnicki, M. J.

    1973-01-01

    A failure evaluation of the transducers used in the environmental control systems of the Apollo command service module, lunar module, and portable life support system is presented in matrix form for several generic categories of transducers to enable identification of chronic failure modes. Transducer vendors were contacted and asked to supply detailed information. The evaluation data generated for each category of transducer were compiled and published in failure design evaluation reports. The evaluation reports also present a review of the failure and design data for the transducers and suggest both design criteria to improve reliability of the transducers and, where necessary, design concepts for required redesign of the transducers. Remedial designs were implemented on a family of pressure transducers and on the oxygen flow transducer. The design concepts were subjected to analysis, breadboard fabrication, and verification testing.

  2. Multi sensor transducer and weight factor

    NASA Technical Reports Server (NTRS)

    Immer, Christopher D. (Inventor); Lane, John (Inventor); Eckhoff, Anthony J. (Inventor); Perotti, Jose M. (Inventor)

    2004-01-01

    A multi-sensor transducer and processing method allow insitu monitoring of the senor accuracy and transducer `health`. In one embodiment, the transducer has multiple sensors to provide corresponding output signals in response to a stimulus, such as pressure. A processor applies individual weight factors to reach of the output signals and provide a single transducer output that reduces the contribution from inaccurate sensors. The weight factors can be updated and stored. The processor can use the weight factors to provide a `health` of the transducer based upon the number of accurate versus in-accurate sensors in the transducer.

  3. Relaxor-based single-crystal materials for ultrasonic transducer applications

    NASA Astrophysics Data System (ADS)

    Park, Seung Eek E.; Lopath, Patrick D.; Shung, K. Kirk; Shrout, Thomas R.

    1997-04-01

    Relaxor ferroelectric single crystals of Pb(Zn1/3Nb2/3)O3 (PZN), Pb(Mg1/3Nb2/3)O3 (PMN) and their solid solutions with normal ferroelectric PbTiO3 (PT) were investigated for ultrasonic transducer applications. Crystals offer adjustable properties not only by compositional tailoring but also by domain state engineering associated with different crystallographic orientation, which is not achievable in polycrystalline materials. Longitudinal coupling coefficients (k33) as high as 94% and dielectric constants (K3T) in the range of 3500 - 6000 were achieved with low dielectric loss (less than 1%) using <001> oriented rhombohedral crystals of (1-x)PZN-xPT and (1-y)PMN-yPT, where x less than 0.09 and y less than 0.35. Dicing direction as well as poling direction were critical for high coupling under laterally clamped condition. Dicing parallel to the (001) yields 90% of laterally clamped coupling (kbar) out of 94% longitudinal coupling (k33) for PZN-8%PT. On the other hand, samples diced parallel to (110) exhibited no dominant mode present. Thickness coupling (kT) as high as 64% and low dielectric constant (K3T) less than 600 with low loss (less than 1%) could be achieved using tetragonal crystals of (1-x)PZN-xPT and (1-y)PMN-yPT, where x greater than 0.1 and y greater than 0.4. The performance gains associated with these ultra-high coupling coefficients and range of dielectric constants are evident in relation to broader bandwidth and electrical impedance matching. Specifically, rhombohedral crystals offer the possibility of extremely broad bandwidth devices for transducer arrays and tetragonal crystals for single element transducers. Transducer simulation was performed using the KLM model. The pulse/echo response simulated a 124% bandwidth subdiced array element with a center frequency of 10 MHz. An optimized array design of the same geometry constructed of PZT 5H displays an 87% bandwidth.

  4. Asymmetric Ultrasonic Pulse Radiation Using Electromagnetic-Induction Transducer and PZT(Pb(Zr-Ti)O3) Transducer with Wave Synthesis Method

    NASA Astrophysics Data System (ADS)

    Endoh, Nobuyuki; Yamamoto, Koji

    1993-05-01

    In medical applications, especially in urology, we use a fragmentation calculus technique with shock waves. This technique is very profitable because of no abdominal surgery for a human being. Large negative sound amplitude pulses, however, can cause problems such as internal hemorrhage or pain in the human body. The final goal of this study is to develop a means to project an intense positive unipolar pulse without negative sound pressure. We improved a composite transducer consisting of an electromagnetic-induction-type (EMI) transducer and PZT (Pb(Zr-Ti)O3) transducers. An EMI transducer consisting of a metal coil and vibration membrane can project intense sound pulses into water. In order to suppress its negative sound pressure, we project a compensation pulse with PZT transducers using an inverse filtering method. An asymmetric pulse whose P+ to P- amplitude ratio was very high was projected in water.

  5. Remote electrically passive position transducer

    NASA Astrophysics Data System (ADS)

    Ducharme, Alfred D.; Markos, Constantine T.; Rieder, R. J.; Wijntjes, Geert J.

    1999-02-01

    We will report on the design and testing of a precision, remote, via fiber optics position transducer suitable for incorporation in a closed loop fly-by-light positioning system. The design is based on Visidyne developed technology for an ultra high resolution optical radar based on Continuous Wave modulated light at a frequency of 1 GHz. It produces digital position data with 12 bit precision e.g., for a travel distance, stroke of 6 inches or greater at a bandwidth, update rate of 1 KHz. The passive nature of the transducer at the actuator location and the high operating frequency makes it highly tolerant to even extreme levels of Electro Magnetic Interference and when constructed from high temperature material is can operate at temperatures well in excess of 300 degrees C. We will discuss transducer performance, precision and position stability with particular emphasis on the effects of length changes within the multi-mode optical fibers used to deliver and collect the light to and from the transducer. We will also discuss cost aspects of the design and their effect on overcoming market entry barriers.

  6. Dynamic Calibration of Pressure Transducers

    NASA Technical Reports Server (NTRS)

    Hess, R. W.; Davis, W. T.; Davis, P. A.

    1985-01-01

    Sinusoidal calibration signal produced in 4- to 100-Hz range. Portable oscillating-pressure device measures dynamic characteristics of pressure transducers installed in models or aircraft at frequency and oscillating-pressure ranges encountered during unsteady-pressure-measurement tests. Calibration is over range of frequencies and amplitudes not available with commercial acoustic calibration devices.

  7. Acoustic transducer for acoustic microscopy

    DOEpatents

    Khuri-Yakub, Butrus T.; Chou, Ching H.

    1990-01-01

    A shear acoustic transducer-lens system in which a shear polarized piezoelectric material excites shear polarized waves at one end of a buffer rod having a lens at the other end which excites longitudinal waves in a coupling medium by mode conversion at selected locations on the lens.

  8. Acoustic transducer for acoustic microscopy

    DOEpatents

    Khuri-Yakub, B.T.; Chou, C.H.

    1990-03-20

    A shear acoustic transducer-lens system is described in which a shear polarized piezoelectric material excites shear polarized waves at one end of a buffer rod having a lens at the other end which excites longitudinal waves in a coupling medium by mode conversion at selected locations on the lens. 9 figs.

  9. Non-bonded ultrasonic transducer

    DOEpatents

    Eoff, J.M.

    1984-07-06

    A mechanically assembled non-bonded ultrasonic transducer includes a substrate, a piezoelectric film, a wetting agent, a thin metal electrode, and a lens held in intimate contact by a mechanical clamp. No epoxy or glue is used in the assembly of this device.

  10. Design and fabrication of bimorph transducer for optimal vibration energy harvesting.

    PubMed

    Bedekar, Vishwas; Oliver, Josiah; Priya, Shashank

    2010-07-01

    High energy density piezoelectric composition corresponding to 0.9Pb(Zr0.56Ti0.44)O3–0.1Pb[(Zn0.8/3Ni0.2/3) Nb2/3]O3 + 2 mol% MnO2 (PZTZNN) and 0.8[Pb(Zr0.52Ti0.48) O3]-0.2[Pb(Zn1/3Nb2/3)O3] (PZTPZN) were synthesized by conventional ceramic processing technique using three different sintering profiles. Plates of the sintered samples were used to fabricate the piezoelectric bimorphs with optimized dimensions to exhibit resonance in the loaded condition in the range of ~200 Hz. An analytical model for energy harvesting from bimorph transducer was developed which was confirmed by experimental measurements. The results of this study clearly show that power density of bimorph transducer can be enhanced by increasing the magnitude of product (d ∙ g), where d is the piezoelectric strain constant and g is the piezoelectric voltage constant. PMID:20941885

  11. Seismic transducer measures small horizontal displacements

    NASA Technical Reports Server (NTRS)

    Greenwood, T. L.

    1965-01-01

    Pendular seismic transducer mounted on base plate measures small horizontal displacements of structures subjected to vibration where no fixed reference point is available. Enclosure of transducer in transparent plastic case prevents air currents from disturbing the pendulum balance.

  12. Wideband Single Crystal Transducer for Bone Characterization

    NASA Technical Reports Server (NTRS)

    Sahul, Raffi

    2015-01-01

    Phase II objectives: Optimize the Phase I transducer for sensitivity; Test different transmit signals for optimum performance; Demonstrate compatibility with electronics; Confirm additional transducer capabilities over conventional systems by calibrating with other methods.

  13. Automatic calibration system for pressure transducers

    NASA Technical Reports Server (NTRS)

    1968-01-01

    Fifty-channel automatic pressure transducer calibration system increases quantity and accuracy for test evaluation calibration. The pressure transducers are installed in an environmental tests chamber and manifolded to connect them to a pressure balance which is uniform.

  14. Magnetometer with miniature transducer and automatic transducer scanning apparatus

    NASA Technical Reports Server (NTRS)

    Breckenridge, R. A.; Debnam, W. J., Jr.; Fales, C. L.; Pohm, A. V.

    1974-01-01

    Magnetometer is simple to operate and has fast response. Transducer is rugged and flat and can measure magnetic fields as close as 0.08 mm from any relatively flat surface. Magnetometer has active region of approximately 0.64 by 0.76 mm and is capable of good spatial resolution of magnetic fields as low as 0.02 Oe (1.6 A/m).

  15. Low-Stress Sealing of Pressure Transducers

    NASA Technical Reports Server (NTRS)

    Kroy, R. E.

    1985-01-01

    Compliant washer seals high pressures without excessive compressive stress on transducer. Conformal washer serves as effective seal for transducer passing through walls of pressure vessel. Washer makes it unnecessary to tighten mounting nut to high torque, which could damage transducer or adversely affect accuracy. Washer also used to seal mountings for temperature sensors and other devices.

  16. Measuring Thicknesses With In Situ Ultrasonic Transducers

    NASA Technical Reports Server (NTRS)

    Dunn, Daniel E.; Cerino, Joseph R.

    1995-01-01

    Several pulsed ultrasonic transducers attached to workpiece for measurement of changes in thicknesses of workpiece at transducer locations during grinding and polishing, according to proposal. Once attached, each transducer remains attached at original position until all grinding and polishing operations complete. In typical application, workpiece glass or ceramic blank destined to become component of optical system.

  17. 21 CFR 870.2880 - Ultrasonic transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Ultrasonic transducer. 870.2880 Section 870.2880...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2880 Ultrasonic transducer. (a) Identification. An ultrasonic transducer is a device applied to the skin to transmit and...

  18. 21 CFR 870.2880 - Ultrasonic transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Ultrasonic transducer. 870.2880 Section 870.2880...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2880 Ultrasonic transducer. (a) Identification. An ultrasonic transducer is a device applied to the skin to transmit and...

  19. 21 CFR 870.2880 - Ultrasonic transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Ultrasonic transducer. 870.2880 Section 870.2880...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2880 Ultrasonic transducer. (a) Identification. An ultrasonic transducer is a device applied to the skin to transmit and...

  20. 21 CFR 870.2880 - Ultrasonic transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Ultrasonic transducer. 870.2880 Section 870.2880...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2880 Ultrasonic transducer. (a) Identification. An ultrasonic transducer is a device applied to the skin to transmit and...

  1. 21 CFR 870.2880 - Ultrasonic transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ultrasonic transducer. 870.2880 Section 870.2880...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2880 Ultrasonic transducer. (a) Identification. An ultrasonic transducer is a device applied to the skin to transmit and...

  2. Development of lead-free single-element ultrahigh frequency (170-320MHz) ultrasonic transducers.

    PubMed

    Lam, Kwok Ho; Ji, Hong Fen; Zheng, Fan; Ren, Wei; Zhou, Qifa; Shung, K Kirk

    2013-07-01

    This paper presents the design, fabrication and characterization of single-element ultrahigh frequency (UHF) ultrasonic transducers in which the center frequency ranged from 170 to 320MHz. The center frequency of >300MHz is the highest value of lead-free ceramic ultrasonic transducers ever reported. With concern in the environmental pollution of lead-based materials, the transducer elements presented in this work were lead-free K0.5Na0.5NbO3/Bi0.5Na0.5TiO3 (KNN/BNT) composite thick films. All transducers were evaluated in a pulse-echo arrangement. The measured -6dB bandwidth of the transducers ranged from 35% to 64%. With the optimized piezoelectric properties of the composite film, the insertion loss of the UHF transducers was measured and determined to range from -50 to -60dB. In addition to the pulse-echo measurement, a 6μm tungsten wire phantom was also imaged with a 205MHz transducer to demonstrate the imaging capability. The measured -6dB axial and lateral resolutions were found to be 12μm and 50μm, respectively. The transducer performance presented in this work is shown to be better or comparable to previously reported results even though the frequency is much higher. PMID:23485349

  3. Development of lead-free single-element ultrahigh frequency (170 – 320 MHz) ultrasonic transducers

    PubMed Central

    Lam, Kwok Ho; Ji, Hong Fen; Zheng, Fan; Ren, Wei; Zhou, Qifa; Shung, K. Kirk

    2013-01-01

    This paper presents the design, fabrication and characterization of single-element ultrahigh frequency (UHF) ultrasonic transducers in which the center frequency ranged from 170 to 320 MHz. The center frequency of > 300 MHz is the highest value of lead-free ceramic ultrasonic transducers ever reported. With concern in the environmental pollution of lead-based materials, the transducer elements presented in this work were lead-free K0.5Na0.5NbO3/Bi0.5Na0.5TiO3 (KNN/BNT) composite thick films. All transducers were evaluated in a pulse-echo arrangement. The measured −6 dB bandwidth of the transducers ranged from 35 to 64 %. With the optimized piezoelectric properties of the composite film, the insertion loss of the UHF transducers was measured and determined to range from −50 to −60 dB. In addition to the pulse-echo measurement, a 6-μm tungsten wire phantom was also imaged with a 205 MHz transducer to demonstrate the imaging capability. The measured −6 dB axial and lateral resolutions were found to be 12 μm and 50 μm, respectively. The transducer performance presented in this work is shown to be better or comparable to previously reported results even though the frequency is much higher. PMID:23485349

  4. Advanced Geothermal Optical Transducer (AGOT)

    SciTech Connect

    2004-09-01

    Today's geothermal pressure-temperature measuring tools are short endurance, high value instruments, used sparingly because their loss is a major expense. In this project LEL offered to build and test a rugged, affordable, downhole sensor capable ofretuming an uninterrupted data stream at pressures and of 10,000 psi and temperatures up to 250 C, thus permitting continuous deep-well logging. It was proposed to meet the need by specializing LEL's patented 'Twin Column Transducer' technology to satisfy the demands of geothermal pressure/temperature measurements. TCT transducers have very few parts, none of which are moving parts, and all of which can be fabricated from high-temperature super alloys or from ceramics; the result is an extremely rugged device, essentially impervious to chemical attack and readily modified to operate at high pressure and temperature. To measure pressure and temperature they capitalize on the relative expansion of optical elements subjected to thermal or mechanical stresses; if one element is maintained at a reference pressure while the other is opened to ambient, the differential displacement then serves as a measure of pressure. A transducer responding to temperature rather than pressure is neatly created by 'inverting' the pressure-measuring design so that both deflecting structures see identical temperatures and temperature gradients, but whose thermal expansion coefficients are deliberately mismatched to give differential expansion. The starting point for development of a PT Tool was the company's model DPT feedback-stabilized 5,000 psi sensor (U.S. Patent 5,311,014, 'Optical Transducer for Measuring Downhole Pressure', claiming a pressure transducer capable of measuring static, dynamic, and true bi-directional differential pressure at high temperatures), shown in the upper portion of Figure 1. The DPT occupies a 1 x 2 x 4-inch volume, weighs 14 ounces, and is accurate to 1 percent of full scale. Employing a pair of identical, low

  5. Self-Calibrating Pressure Transducer

    NASA Technical Reports Server (NTRS)

    Lueck, Dale E. (Inventor)

    2006-01-01

    A self-calibrating pressure transducer is disclosed. The device uses an embedded zirconia membrane which pumps a determined quantity of oxygen into the device. The associated pressure can be determined, and thus, the transducer pressure readings can be calibrated. The zirconia membrane obtains oxygen .from the surrounding environment when possible. Otherwise, an oxygen reservoir or other source is utilized. In another embodiment, a reversible fuel cell assembly is used to pump oxygen and hydrogen into the system. Since a known amount of gas is pumped across the cell, the pressure produced can be determined, and thus, the device can be calibrated. An isolation valve system is used to allow the device to be calibrated in situ. Calibration is optionally automated so that calibration can be continuously monitored. The device is preferably a fully integrated MEMS device. Since the device can be calibrated without removing it from the process, reductions in costs and down time are realized.

  6. Split-mode ultrasonic transducer.

    PubMed

    Ostrovskii, Igor; Cremaldi, Lucien

    2013-08-01

    A split-mode ultrasonic transducer is investigated in both theory and experiment. This transducer is a two-dimensional structure of periodically poled domains in a ferroelectric wafer with free surfaces. The acoustic vibrations are excited by a radio frequency electric current applied along the length of the wafer, which allows the basal-plane surfaces to be free of metal coatings and thus ready for further biomedical applications. A specific physical property of this transducer consists of the multiple acousto-electric resonances, which occur due to an acoustic mode split when the acoustic half-wavelength is equal to the domain length. Possible applications include ultrasonic generation and detection at the micro-scale, intravascular sonification and visualization, ultrasound therapy of localized small areas such as the eye, biomedical applications for cell cultures, and traditional nondestructive testing including bones and tissues. A potential use of a non-metallized wafer is a therapeutic application with double action that is both ultrasound itself and an electric field over the wafer. The experimental measurements and theoretical calculations are in good agreement. PMID:23927212

  7. A 1,3-Dihydro-1,3-azaborine Debuts

    PubMed Central

    Xu, Senmiao; Zakharov, Lev N.

    2011-01-01

    We present the first synthesis and characterization of a 1,3-dihydro-1,3-azaborine, a long-sought BN isostere of benzene. 1,3-Dihydro-1,3-azaborine is a stable structural motif with considerable aromatic character as evidenced by structural analysis and its reaction chemistry. Single crystal X-ray analysis indicates bonding consistent with significant electron delocalization. 1,3-Dihydro-1,3-azaborines also undergo nucleophilic substitutions at boron and electrophilic aromatic substitution reactions. In view of the versatility and impact of aromatic compounds in the biomedical field and in materials science, the present study further expands the available chemical space of arenes via BN/CC isosterism. PMID:22091703

  8. Wideband focused transducer array for optoacoustic tomography

    NASA Astrophysics Data System (ADS)

    Simonova, V. A.; Khokhlova, T. D.; Karabutov, A. A.

    2009-11-01

    The calculation procedure of the parameters of a multielement transducer array for the optoacoustic tomography of biological objects with high spatial resolution values is proposed. A multielement transducer with given spatial resolution values in three dimensions has been developed based on the proposed procedure for the early detection of breast cancer. The transducer array consists of a set of 8 linear PVDF piezoelectric films located on a plane and a focusing cylindrical acoustic lens. A map of the transducer’s focal area and point spread function have been measured using the constructed transducer array. Spatial resolutions of the transducer array obtained experimentally are in agreement with their calculated values.

  9. Acoustic transducer for nuclear reactor monitoring

    DOEpatents

    Ahlgren, Frederic F.; Scott, Paul F.

    1977-01-01

    A transducer to monitor a parameter and produce an acoustic signal from which the monitored parameter can be recovered. The transducer comprises a modified Galton whistle which emits a narrow band acoustic signal having a frequency dependent upon the parameter being monitored, such as the temperature of the cooling media of a nuclear reactor. Multiple locations within a reactor are monitored simultaneously by a remote acoustic receiver by providing a plurality of transducers each designed so that the acoustic signal it emits has a frequency distinct from the frequencies of signals emitted by the other transducers, whereby each signal can be unambiguously related to a particular transducer.

  10. Model-based optimization of ultrasonic transducers.

    PubMed

    Heikkola, Erkki; Laitinen, Mika

    2005-01-01

    Numerical simulation and automated optimization of Langevin-type ultrasonic transducers are investigated. These kind of transducers are standard components in various applications of high-power ultrasonics such as ultrasonic cleaning and chemical processing. Vibration of the transducer is simulated numerically by standard finite element method and the dimensions and shape parameters of a transducer are optimized with respect to different criteria. The novelty value of this work is the combination of the simulation model and the optimization problem by efficient automatic differentiation techniques. The capabilities of this approach are demonstrated with practical test cases in which various aspects of the operation of a transducer are improved. PMID:15474952

  11. Characterization of dielectric electroactive polymer transducers

    NASA Astrophysics Data System (ADS)

    Nielsen, Dennis; Møller, Martin B.; Sarban, Rahimullah; Lassen, Benny; Knott, Arnold; Andersen, Michael A. E.

    2014-03-01

    Throughout this paper, a small-signal model of the Dielectric Electro Active Polymer (DEAP) transducer is analyzed. The DEAP transducer have been proposed as an alternative to the electrodynamic transducer in sound reproduction systems. In order to understand how the DEAP transducer works, and provide guidelines for design optimization, accurate characterization of the transducer must be established. A small signal model of the DEAP transducer is derived and its validity is investigated using impedance measurements. Impedance measurements are shown for a push-pull DEAP based loudspeaker, and the dependency of the biasing voltage is explained. A measuring setup is proposed, which allows the impedance to be measured, while the DEAP transducer is connected to its biasing source.

  12. Thermal-independent properties of PIN-PMN-PT single-crystal linear-array ultrasonic transducers.

    PubMed

    Chen, Ruimin; Wu, Jinchuan; Ho Lam, Kwok; Yao, Liheng; Zhou, Qifa; Tian, Jian; Han, Pengdi; Shung, K Kirk

    2012-12-01

    In this paper, low-frequency 32-element linear-array ultrasonic transducers were designed and fabricated using both ternary Pb(In(1/2)Nb(1/2))-Pb(Mg(1/3)Nb(2/3))-PbTiO(3) (PIN-PMN-PT) and binary Pb(Mg(1/3)Nb(2/3))-PbTiO(3) (PMNPT) single crystals. Performance of the array transducers was characterized as a function of temperature ranging from room temperature to 160°C. It was found that the array transducers fabricated using the PIN-PMN-PT single crystal were capable of satisfactory performance at 160°C, having a -6-dB bandwidth of 66% and an insertion loss of 37 dB. The results suggest that the potential of PIN-PMN-PT linear-array ultrasonic transducers for high-temperature ultrasonic transducer applications is promising. PMID:23221227

  13. Tonpilz Underwater Acoustic Transducer Integrating Lead-free Piezoelectric Material

    NASA Astrophysics Data System (ADS)

    Rouffaud, Rémi; Granger, Christian; Hladky-Hennion, Anne-Christine; Thi, Mai Pham; Levassort, Franck

    A Tonpilz transducer based on lead-free piezoelectric material was fabricated, modeled and characterized. The stack is composed of two rings of doped BaTiO3. This composition was initially chosen due to good electromechanical performance (kt at 40%) and high mechanical quality factor (Qm over 500). Comparison of the displacement at the center of the head mass was performed with a PZT-based Tonpilz with the same design for a center frequency at 22 kHz.

  14. Solar cell angular position transducer

    NASA Technical Reports Server (NTRS)

    Sandford, M. C.; Gray, D. L. (Inventor)

    1980-01-01

    An angular position transducer utilizing photocells and a light source is disclosed. The device uses a fully rotatable baffle which is connected via an actuator shaft to the body whose rotational displacement is to be measured. The baffle blocks the light path between the light source and the photocells so that a constant semicircular beam of light reaches the photocells. The current produced by the photocells is fed through a resistor, a differential amplifier measures the voltage drop across the resistor which indicates the angular position of the actuator shaft and hence of the object.

  15. Shear wave transducer for boreholes

    DOEpatents

    Mao, N.H.

    1984-08-23

    A technique and apparatus is provided for estimating in situ stresses by measuring stress-induced velocity anisotropy around a borehole. Two sets each of radially and tangentially polarized transducers are placed inside the hole with displacement directions either parallel or perpendicular to the principal stress directions. With this configuration, relative travel times are measured by both a pulsed phase-locked loop technique and a cross correlation of digitized waveforms. The biaxial velocity data are used to back-calculate the applied stress.

  16. Ultrasonic 2D matrix PVDF transducer

    NASA Astrophysics Data System (ADS)

    Ptchelintsev, A.; Maev, R. Gr.

    2000-05-01

    During the past decade a substantial amount of work has been done in the area of ultrasonic imaging technology using 2D arrays. The main problems arising for the two-dimensional matrix transducers at megahertz frequencies are small size and huge count of the elements, high electrical impedance, low sensitivity, bad SNR and slower data acquisition rate. The major technological difficulty remains the high density of the interconnect. To solve these problems numerous approaches have been suggested. In the present work, a 24×24 elements (24 transmit+24 receive) matrix and a switching board were developed. The transducer consists of two 52 μm PVDF layers each representing a linear array of 24 elements placed one on the top of the other. Electrodes in these two layers are perpendicular and form the grid of 0.5×0.5 mm pitch. The layers are bonded together with the ground electrode being monolithic and located between the layers. The matrix is backed from the rear surface with an epoxy composition. During the emission, a linear element from the emitting layer generates a longitudinal wave pulse propagating inside the test object. Reflected pulses are picked-up by the receiving layer. During one transmit-receive cycle one transmit element and one receive element are selected by corresponding multiplexers. These crossed elements emulate a small element formed by their intersection. The present design presents the following advantages: minimizes number of active channels and density of the interconnect; reduces the electrical impedance of the element improving electrical matching; enables the transmit-receive mode; due to the efficient backing provides bandwidth and good time resolution; and, significantly reduces the electronics complexity. The matrix can not be used for the beam steering and focusing. Owing to this impossibility of focusing, the penetration depth is limited as well by the diffraction phenomena.

  17. Investigation of capacitively coupled ultrasonic transducer system for nondestructive evaluation.

    PubMed

    Zhong, Cheng Huan; Wilcox, Paul D; Croxford, Anthony J

    2013-12-01

    Capacitive coupling offers a simple solution to wirelessly probe ultrasonic transducers. This paper investigates the theory, feasibility, and optimization of such a capacitively coupled transducer system (CCTS) in the context of nondestructive evaluation (NDE) applications. The noncontact interface relies on an electric field formed between four metal plates-two plates are physically connected to the electrodes of a transducer, the other two are in a separate probing unit connected to the transmit/receive channel of the instrumentation. The complete system is modeled as an electric network with the measured impedance of a bonded piezoelectric ceramic disc representing a transducer attached to an arbitrary solid substrate. A transmission line model is developed which is a function of the physical parameters of the capacitively coupled system, such as the permittivity of the material between the plates, the size of the metal plates, and their relative positions. This model provides immediate prediction of electric input impedance, pulse-echo response, and the effect of plate misalignment. The model has been validated experimentally and has enabled optimization of the various parameters. It is shown that placing a tuning inductor and series resistor on the transmitting side of the circuit can significantly improve the system performance in terms of the signal-to-crosstalk ratio. Practically, bulk-wave CCTSs have been built and demonstrated for underwater and through-composite testing. It has been found that electrical conduction in the media between the plates limits their applications. PMID:24297024

  18. Development of high frequency focused transducers for single beam acoustic tweezers

    NASA Astrophysics Data System (ADS)

    Hsu, Hsiu-Sheng

    propose a simple and efficient approach to prepare xPMN-PT-(1-x)PZT (where x is 0.1, 0.3, 0.5, 0.7 and 0.9) composite films with controllable dielectric constant that offers better performance for high frequency ultrasonic transducer applications. A 200 MHz single element transducer utilizing 0.9PMN-PT-0.1PZT thin film was built. This type of xPMN-PT-(1-x)PZT film transducers may satisfy current needs of very high frequency biomedical applications, such as ultrasonic biomicroscopy or acoustic tweezers.

  19. Analog circuit for controlling acoustic transducer arrays

    DOEpatents

    Drumheller, Douglas S.

    1991-01-01

    A simplified ananlog circuit is presented for controlling electromechanical transducer pairs in an acoustic telemetry system. The analog circuit of this invention comprises a single electrical resistor which replaces all of the digital components in a known digital circuit. In accordance with this invention, a first transducer in a transducer pair of array is driven in series with the resistor. The voltage drop across this resistor is then amplified and used to drive the second transducer. The voltage drop across the resistor is proportional and in phase with the current to the transducer. This current is approximately 90 degrees out of phase with the driving voltage to the transducer. This phase shift replaces the digital delay required by the digital control circuit of the prior art.

  20. ERROR COMPENSATOR FOR A POSITION TRANSDUCER

    DOEpatents

    Fowler, A.H.

    1962-06-12

    A device is designed for eliminating the effect of leadscrew errors in positioning machines in which linear motion of a slide is effected from rotary motion of a leadscrew. This is accomplished by providing a corrector cam mounted on the slide, a cam follower, and a transducer housing rotatable by the follower to compensate for all the reproducible errors in the transducer signal which can be related to the slide position. The transducer has an inner part which is movable with respect to the transducer housing. The transducer inner part is coupled to the means for rotating the leadscrew such that relative movement between this part and its housing will provide an output signal proportional to the position of the slide. The corrector cam and its follower perform the compensation by changing the angular position of the transducer housing by an amount that is a function of the slide position and the error at that position. (AEC)

  1. TRPC channels as signal transducers.

    PubMed

    Glazebrook, Patricia A; Schilling, William P; Kunze, Diana L

    2005-10-01

    The study of the TRPC cation channels as signal transducers in sensory neurons is in its infancy. Mechanoreceptors that monitor arterial pressure are prime candidates for the involvement of TRPC channels as either primary mechanical transducers or as modulators of the transduction process. Their activity patterns can be regulated by growth factors such as BDNF and by a variety of ligands that activate Gq-coupled receptors, mechanisms that have been shown in heterologous expression systems to activate TRPC channels. We investigated the distribution of TRPC1 and TRPC3-7 in nodose sensory neurons and in their peripheral axons that terminate as mechanosensitive receptors in the aortic arch of the rat. Using immunocytochemical techniques we identified these six TRPC proteins in the soma of the nodose neurons but only TRPC1 and TRPC3-5 were found to distribute to the peripheral axons and the mechanosensory terminals. TRPC1 and TRPC3 extended into the low threshold complex sensory endings with very strong labeling. In contrast, TRPC4 and TRPC5 were found primarily in major branches of the receptor but immunoreactivity was weak in the region where mechanotransduction is presumed to occur. Terminals arising from unmyelinated fibers also expressed TRPC1 and TRPC3-5 but not all fibers expressed all of the channels suggesting that specific TRPC protein may be aligned with previously described subclasses of the unmyelinated C-fibers. PMID:15971079

  2. Silicon Integrated Cavity Optomechanical Transducer

    NASA Astrophysics Data System (ADS)

    Zou, Jie; Miao, Houxun; Michels, Thomas; Liu, Yuxiang; Srinivasan, Kartik; Aksyuk, Vladimir

    2013-03-01

    Cavity optomechanics enables measurements of mechanical motion at the fundamental limits of precision imposed by quantum mechanics. However, the need to align and couple devices to off-chip optical components hinders development, miniaturization and broader application of ultrahigh sensitivity chip-scale optomechanical transducers. Here we demonstrate a fully integrated and optical fiber pigtailed optomechanical transducer with a high Q silicon micro-disk cavity near-field coupled to a nanoscale cantilever. We detect the motion of the cantilever by measuring the resonant frequency shift of the whispering gallery mode of the micro-disk. The sensitivity near the standard quantum limit can be reached with sub-uW optical power. Our on-chip approach combines compactness and stability with great design flexibility: the geometry of the micro-disk and cantilever can be tailored to optimize the mechanical/optical Q factors and tune the mechanical frequency over two orders of magnitudes. Electrical transduction in addition to optical transduction was also demonstrated and both can be used to effectively cool the cantilever. Moreover, cantilevers with sharp tips overhanging the chip edge were fabricated to potentially allow the mechanical cantilever to be coupled to a wide range of off-chip systems, such as spins, DNA, nanostructures and atoms on clean surfaces.

  3. Lead-free piezoelectric materials and ultrasonic transducers for medical imaging

    NASA Astrophysics Data System (ADS)

    Taghaddos, Elaheh; Hejazi, Mehdi; Safari, Ahmad

    2015-06-01

    Piezoelectric materials have been vastly used in ultrasonic transducers for medical imaging. In this paper, firstly, the most promising lead-free compositions with perovskite structure for medical imaging applications have been reviewed. The electromechanical properties of various lead-free ceramics, composites, and single crystals based on barium titanate, bismuth sodium titanate, potassium sodium niobate, and lithium niobate are presented. Then, fundamental principles and design considerations of ultrasonic transducers are briefly described. Finally, recent developments in lead-free ultrasonic probes are discussed and their acoustic performance is compared to lead-based transducers. Focused transducers with different beam focusing methods such as lens focusing and mechanical shaping are explained. Additionally, acoustic characteristics of lead-free probes including the pulse-echo results as well as their imaging capabilities for various applications such as phantom imaging, in vitro intravascular ultrasound imaging of swine aorta, and in vivo or ex vivo imaging of human eyes and skin are reviewed.

  4. Two-Element Transducer for Ultrasound

    NASA Technical Reports Server (NTRS)

    Lecroissette, D. H.; Heyser, R. C.

    1986-01-01

    Separation of transmitting and receiving units improves probing of deep tissue. Ultrasonic transducer has dual elements to increase depth at which sonic images are made of biological tissue. Transducer uses separate transmitting and receiving elements, and frequency response of receiving element independently designed to accommodate attenuation of higher frequencies by tissue. New transducer intended for pulse-echo ultrasonic systems in which reflected sound pulses reveal features in tissue.

  5. Phased annular array transducers for omnidirectional guided wave mode control in isotropic plate like structures

    NASA Astrophysics Data System (ADS)

    Koduru, Jaya P.; Momeni, Sepandarmaz; Rose, Joseph L.

    2013-12-01

    Ultrasonic guided waves are fast emerging as a reliable tool for continuous structural health monitoring. Their multi-modal nature along with their long range propagation characteristics offer several possibilities for interrogating structures. Transducers commonly used to generate guided waves in structures excite multiple modes at any frequency; their complex scattering and reflection from defects and boundaries often complicates the extraction of useful information. Often it is desirable to control the guided wave modes propagating in a structure to take advantage of their unique properties for different applications. Earlier attempts at guided wave mode control involved developing fixed wavelength linear and annular array transducers. Their only disadvantage is that the transducer is limited to a particular wavelength and a change in wavelength necessitates a change in the transducer. In this paper, we propose the development of an annular array transducer that can generate mode controlled omnidirectional guided waves by independently controlling the amplitude and phase of the array elements. A simplified actuator model that approximates the transducer loading on the structure to a constant pressure load under the array elements is assumed and an optimization problem is set up to compute the excitation voltage and phase of the elements. A five element annular array transducer is designed utilizing 1-3 type piezocomposite materials. The theoretical computations are experimentally verified on an aluminum plate like structure by exciting A0 and S0 guided wave modes.

  6. Measurement methods of ultrasonic transducer sensitivity.

    PubMed

    Xiao, Dingguo; Fan, Qiong; Xu, Chunguang; Zhang, Xiuhua

    2016-05-01

    Sensitivity is an important parameter to describe the electro-acoustic energy conversion efficiency of ultrasonic transducer. In this paper, the definition of sensitivity and reciprocity of ultrasonic transducer is studied. The frequency response function of a transducer is the spectrum of its sensitivity, which reflects the response sensitivity of the transducer for input signals at different frequencies. Four common methods which are used to measure the disc-vibrator transducer sensitivity are discussed in current investigation. The reciprocity method and the pulse-echo method are based on the reciprocity of the transducer. In the laser vibrometer method measurement, the normal velocity on the transducer radiating surface is directly measured by a laser vibrometer. In the measurement process of the hydrophone method, a calibrated hydrophone is used to measure the transmitted field. The validity of these methods is checked by experimental test. All of the four methods described are sufficiently accurate for transducer sensitivity measurement, while each method has its advantages and limitations. In practical applications, the appropriate method to measure transducer sensitivity should be selected based on actual conditions. PMID:26953638

  7. STIMULUS AND TRANSDUCER EFFECTS ON THRESHOLD

    PubMed Central

    Flamme, Gregory A.; Geda, Kyle; McGregor, Kara; Wyllys, Krista; Deiters, Kristy K.; Murphy, William J.; Stephenson, Mark R.

    2015-01-01

    Objective This study examined differences in thresholds obtained under Sennheiser HDA200 circumaural earphones using pure tone, equivalent rectangular noise bands, and 1/3 octave noise bands relative to thresholds obtained using Telephonics TDH-39P supra-aural earphones. Design Thresholds were obtained via each transducer and stimulus condition six times within a 10-day period. Study Sample Forty-nine adults were selected from a prior study to represent low, moderate, and high threshold reliability. Results The results suggested that (1) only small adjustments were needed to reach equivalent TDH-39P thresholds, (2) pure-tone thresholds obtained with HDA200 circumaural earphones had reliability equal to or better than those obtained using TDH-39P earphones, (3) the reliability of noise-band thresholds improved with broader stimulus bandwidth and was either equal to or better than pure-tone thresholds, and (4) frequency-specificity declined with stimulus bandwidths greater than one Equivalent Rectangular Band, which could complicate early detection of hearing changes that occur within a narrow frequency range. Conclusions These data suggest that circumaural earphones such as the HDA200 headphones provide better reliability for audiometric testing as compared to the TDH-39P earphones. These data support the use of noise bands, preferably ERB noises, as stimuli for audiometric monitoring. PMID:25549164

  8. High temperature ultrasonic transducers for the generation of guided waves for non-destructive evaluation of pipes

    SciTech Connect

    Sinding, K.; Searfass, C.; Malarich, N.; Reinhardt, B.; Tittmann, B. R.

    2014-02-18

    Applications for non-destructive evaluation and structural health monitoring of steam generators require ultrasonic transducers capable of withstanding the high temperatures of the pipes and heat exchangers. These applications require a strong coupling of the transducer to the heat exchanger’s complex geometry at the elevated temperatures. Our objective is to use spray-on piezo-electrics for depositing comb transducers onto the curved surfaces. This paper shows results for composite transducers such as lead zirconate titanate/ bismuth titanate and bismuth titanate/ lithium niobate. The comb transducers were prepared by precision laser ablation. The feasibility of producing second harmonic waves in rods with these spay-on comb transducers was demonstrated and paves the way toward measuring material degradation early-on before crack initiation occurs.

  9. High temperature ultrasonic transducers for the generation of guided waves for non-destructive evaluation of pipes

    NASA Astrophysics Data System (ADS)

    Sinding, K.; Searfass, C.; Malarich, N.; Reinhardt, B.; Tittmann, B. R.

    2014-02-01

    Applications for non-destructive evaluation and structural health monitoring of steam generators require ultrasonic transducers capable of withstanding the high temperatures of the pipes and heat exchangers. These applications require a strong coupling of the transducer to the heat exchanger's complex geometry at the elevated temperatures. Our objective is to use spray-on piezo-electrics for depositing comb transducers onto the curved surfaces. This paper shows results for composite transducers such as lead zirconate titanate/ bismuth titanate and bismuth titanate/ lithium niobate. The comb transducers were prepared by precision laser ablation. The feasibility of producing second harmonic waves in rods with these spay-on comb transducers was demonstrated and paves the way toward measuring material degradation early-on before crack initiation occurs.

  10. Nuclear Radiation Tolerance of Single Crystal Aluminum Nitride Ultrasonic Transducer

    NASA Astrophysics Data System (ADS)

    Reinhard, Brian; Tittmann, Bernhard R.; Suprock, Andrew

    Ultrasonic technologies offer the potential for high accuracy and resolution in-pile measurement of a range of parameters, including geometry changes, temperature, crack initiation and growth, gas pressure and composition, and microstructural changes. Many Department of Energy-Office of Nuclear Energy (DOE-NE) programs are exploring the use of ultrasonic technologies to provide enhanced sensors for in-pile instrumentation during irradiation testing. For example, the ability of small diameter ultrasonic thermometers (UTs) to provide a temperature profile in candidate metallic and oxide fuel would provide much needed data for validating new fuel performance models, (Rempe et al., 2011; Kazys et al., 2005). These efforts are limited by the lack of identified ultrasonic transducer materials capable of long term performance under irradiation test conditions. To address this need, the Pennsylvania State University (PSU) was awarded an Advanced Test Reactor National Scientific User Facility (ATR NSUF) project to evaluate the performance of promising magnetostrictive and piezoelectric transducers in the Massachusetts Institute of Technology Research Reactor (MITR) up to a fast fluence of at least 1021 n/cm2. The irradiation is also supported by a multi-National Laboratory collaboration funded by the Nuclear Energy Enabling Technologies Advanced Sensors and Instrumentation (NEET ASI) program. The results from this irradiation, which started in February 2014, offer the potential to enable the development of novel radiation tolerant ultrasonic sensors for use in Material Testing Reactors (MTRs). As such, this test is an instrumented lead test and real-time transducer performance data is collected along with temperature and neutron and gamma flux data. Hence, results from this irradiation offer the potential to bridge the gap between proven out-of-pile ultrasonic techniques and in-pile deployment of ultrasonic sensors by acquiring the data necessary to demonstrate the

  11. Investigation of inductively coupled ultrasonic transducer system for NDE.

    PubMed

    Zhong, Cheng Huan; Croxford, Anthony J; Wilcox, Paul D

    2013-06-01

    Inductive coupling offers a simple solution to wirelessly probe ultrasonic transducers. This paper investigates the theory and feasibility of such an inductively coupled transducer system in the context of nondestructive evaluation (NDE) applications. The noncontact interface is based on electromagnetic coupling between three coils; one of the coils is physically connected to the transducer, the other two are in a separate probing unit, where they are connected to the transmit and receive channels of the instrumentation. The complete system is modeled as a three-port network with the measured impedance of a bonded piezoelectric ceramic disc representing a sensor attached to an arbitrary solid substrate. The developed transmission line model is a function of the physical parameters of the electromagnetic system, such as the number of turns and diameter of each coil, and their separation. This model provides immediate predictions of electrical input impedance and pulse-echo response. The model has been validated experimentally and a sensitivity analysis of the input parameters performed. This has enabled optimization of the various parameters. Inductively coupled transducer systems have been built for both bulk and guided wave examples. By using chirped excitation and baseline subtraction, inspection distance of up to 700 mm is achieved in single-shot, guided-wave pulse-echo mode measurements with a 5 mm separation between the probing coils and transducer coil on an aluminum plate structure. In the bulk wave example, a delamination in an 8.9-mm-thick carbon fiber composite specimen is successfully identified from the changes in the arrival time of a reflected pulse. PMID:25004474

  12. Standards for dielectric elastomer transducers

    NASA Astrophysics Data System (ADS)

    Carpi, Federico; Anderson, Iain; Bauer, Siegfried; Frediani, Gabriele; Gallone, Giuseppe; Gei, Massimiliano; Graaf, Christian; Jean-Mistral, Claire; Kaal, William; Kofod, Guggi; Kollosche, Matthias; Kornbluh, Roy; Lassen, Benny; Matysek, Marc; Michel, Silvain; Nowak, Stephan; O'Brien, Benjamin; Pei, Qibing; Pelrine, Ron; Rechenbach, Björn; Rosset, Samuel; Shea, Herbert

    2015-10-01

    Dielectric elastomer transducers consist of thin electrically insulating elastomeric membranes coated on both sides with compliant electrodes. They are a promising electromechanically active polymer technology that may be used for actuators, strain sensors, and electrical generators that harvest mechanical energy. The rapid development of this field calls for the first standards, collecting guidelines on how to assess and compare the performance of materials and devices. This paper addresses this need, presenting standardized methods for material characterisation, device testing and performance measurement. These proposed standards are intended to have a general scope and a broad applicability to different material types and device configurations. Nevertheless, they also intentionally exclude some aspects where knowledge and/or consensus in the literature were deemed to be insufficient. This is a sign of a young and vital field, whose research development is expected to benefit from this effort towards standardisation.

  13. The Current State of Silicone-Based Dielectric Elastomer Transducers.

    PubMed

    Madsen, Frederikke B; Daugaard, Anders E; Hvilsted, Søren; Skov, Anne L

    2016-03-01

    Silicone elastomers are promising materials for dielectric elastomer transducers (DETs) due to their superior properties such as high efficiency, reliability and fast response times. DETs consist of thin elastomer films sandwiched between compliant electrodes, and they constitute an interesting class of transducer due to their inherent lightweight and potentially large strains. For the field to progress towards industrial implementation, a leap in material development is required, specifically targeting longer lifetime and higher energy densities to provide more efficient transduction at lower driving voltages. In this review, the current state of silicone elastomers for DETs is summarised and critically discussed, including commercial elastomers, composites, polymer blends, grafted elastomers and complex network structures. For future developments in the field it is essential that all aspects of the elastomer are taken into account, namely dielectric losses, lifetime and the very often ignored polymer network integrity and stability. PMID:26773231

  14. Photoelastic transducer for high-temperature applications

    NASA Technical Reports Server (NTRS)

    Redner, A. S.; Adamovsky, Grigory; Wesson, L. N.

    1990-01-01

    A design for a birefringence transducer for high-temperature applications is described. The spring element and the readout instrumentation are addressed. A pressure transducer based on the concept has been built and successfully tested at temperatures up to 600 C.

  15. Opto-acoustic transducer for medical applications

    DOEpatents

    Benett, William; Celliers, Peter; Da Silva, Luiz; Glinsky, Michael; London, Richard; Maitland, Duncan; Matthews, Dennis; Krulevich, Peter; Lee, Abraham

    1999-01-01

    This invention is an optically activated transducer for generating acoustic vibrations in a biological medium. The transducer is located at the end of a fiber optic which may be located within a catheter. Energy for operating the transducer is provided optically by laser light transmitted through the fiber optic to the transducer. Pulsed laser light is absorbed in the working fluid of the transducer to generate a thermal pressure and consequent adiabatic expansion of the transducer head such that it does work against the ambient medium. The transducer returns to its original state by a process of thermal cooling. The motion of the transducer within the ambient medium couples acoustic energy into the medium. By pulsing the laser at a high repetition rate (which may vary from CW to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus. The catheter may also incorporate anti-thrombolytic drug treatments as an adjunct therapy and it may be operated in conjunction with ultrasonic detection equipment for imaging and feedback control.

  16. Opto-acoustic transducer for medical applications

    DOEpatents

    Benett, W.; Celliers, P.; Da Silva, L.; Glinsky, M.; London, R.; Maitland, D.; Matthews, D.; Krulevich, P.; Lee, A.

    1999-08-31

    This invention is an optically activated transducer for generating acoustic vibrations in a biological medium. The transducer is located at the end of a fiber optic which may be located within a catheter. Energy for operating the transducer is provided optically by laser light transmitted through the fiber optic to the transducer. Pulsed laser light is absorbed in the working fluid of the transducer to generate a thermal pressure and consequent adiabatic expansion of the transducer head such that it does work against the ambient medium. The transducer returns to its original state by a process of thermal cooling. The motion of the transducer within the ambient medium couples acoustic energy into the medium. By pulsing the laser at a high repetition rate (which may vary from CW to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus. The catheter may also incorporate anti-thrombolytic drug treatments as an adjunct therapy and it may be operated in conjunction with ultrasonic detection equipment for imaging and feedback control. 7 figs.

  17. Opto-acoustic transducer for medical applications

    DOEpatents

    Benett, William; Celliers, Peter; Da Silva, Luiz; Glinsky, Michael; London, Richard; Maitland, Duncan; Matthews, Dennis; Krulevich, Peter; Lee, Abraham

    2002-01-01

    This invention is an optically activated transducer for generating acoustic vibrations in a biological medium. The transducer is located at the end of a fiber optic which may be located within a catheter. Energy for operating the transducer is provided optically by laser light transmitted through the fiber optic to the transducer. Pulsed laser light is absorbed in the working fluid of the transducer to generate a thermal pressure and consequent adiabatic expansion of the transducer head such that it does work against the ambient medium. The transducer returns to its original state by a process of thermal cooling. The motion of the transducer within the ambient medium couples acoustic energy into the medium. By pulsing the laser at a high repetition rate (which may vary from CW to 100 kHz) an ultrasonic radiation field can be established locally in the medium. This method of producing ultrasonic vibrations can be used in vivo for the treatment of stroke-related conditions in humans, particularly for dissolving thrombus. The catheter may also incorporate anti-thrombolytic drug treatments as an adjunct therapy and it may be operated in conjunction with ultrasonic detection equipment for imaging and feedback control.

  18. Hot foil transducer skin friction sensor

    NASA Technical Reports Server (NTRS)

    Vranas, T. (Inventor)

    1982-01-01

    The device utilizes foil transducers with only one edge exposed to the fluid flow. The surfaces are polished producing a foil transducer that does not generate turbulence while sufficiently thick to carry the required electrical current for high temperature fluid flow. The assembly utilizes a precut layered metal sandwich with attached electrodes eliminating a need for welding and individual sensor calibration.

  19. Thermodynamic Pressure/Temperature Transducer Health Check

    NASA Technical Reports Server (NTRS)

    Immer, Christopher D. (Inventor); Eckhoff, Anthony (Inventor); Medelius, Pedro J. (Inventor); Deyoe, Richard T. (Inventor); Starr, Stanley O. (Inventor)

    2004-01-01

    A device and procedure for checking the health of a pressure transducer in situ is provided. The procedure includes measuring a fixed change in pressure above ambient pressure and a fixed change in pressure below ambient pressure. This is done by first sealing an enclosed volume around the transducer with a valve. A piston inside the sealed volume is increasing the pressure. A fixed pressure below ambient pressure is obtained by opening the valve, driving the piston The output of the pressure transducer is recorded for both the overpressuring and the underpressuring. By comparing this data with data taken during a preoperative calibration, the health of the transducer is determined from the linearity, the hysteresis, and the repeatability of its output. The further addition of a thermometer allows constant offset error in the transducer output to be determined.

  20. Using Portable Transducers to Measure Tremor Severity

    PubMed Central

    Elble, Rodger J.; McNames, James

    2016-01-01

    Background Portable motion transducers, suitable for measuring tremor, are now available at a reasonable cost. The use of these transducers requires knowledge of their limitations and data analysis. The purpose of this review is to provide a practical overview and example software for using portable motion transducers in the quantification of tremor. Methods Medline was searched via PubMed.gov in December 2015 using the Boolean expression “tremor AND (accelerometer OR accelerometry OR gyroscope OR inertial measurement unit OR digitizing tablet OR transducer).” Abstracts of 419 papers dating back to 1964 were reviewed for relevant portable transducers and methods of tremor analysis, and 105 papers written in English were reviewed in detail. Results Accelerometers, gyroscopes, and digitizing tablets are used most commonly, but few are sold for the purpose of measuring tremor. Consequently, most software for tremor analysis is developed by the user. Wearable transducers are capable of recording tremor continuously, in the absence of a clinician. Tremor amplitude, frequency, and occurrence (percentage of time with tremor) can be computed. Tremor amplitude and occurrence correlate strongly with clinical ratings of tremor severity. Discussion Transducers provide measurements of tremor amplitude that are objective, precise, and valid, but the precision and accuracy of transducers are mitigated by natural variability in tremor amplitude. This variability is so great that the minimum detectable change in amplitude, exceeding random variability, is comparable for scales and transducers. Research is needed to determine the feasibility of detecting smaller change using averaged data from continuous long-term recordings with wearable transducers. PMID:27257514

  1. Comparison of the properties of tonpilz transducers fabricated with 001 fiber-textured lead magnesium niobate-lead titanate ceramic and single crystals.

    PubMed

    Brosnan, Kristen H; Messing, Gary L; Markley, Douglas C; Meyer, Richard J

    2009-11-01

    Tonpilz transducers are fabricated from 001 fiber-textured 0.72Pb(Mg(1/3)Nb(2/3))O(3)-0.28PbTiO(3) (PMN-28PT) ceramics, obtained by the templated grain growth process, and PMN-28PT ceramic and Bridgman grown single crystals of the same composition. In-water characterization of single element transducers shows higher source levels, higher in-water coupling, and more usable bandwidth for the 81 vol % textured PMN-28PT device than for the ceramic PMN-28PT element. The 81 vol % textured PMN-28PT tonpilz element measured under large signals shows linearity in sound pressure levels up to 0.23 MV/m drive field but undergoes a phase transition due to a lowered transition temperature from the SrTiO(3) template particles. Although the textured ceramic performs well in this application, it could be further improved with compositional tailoring to raise the transition temperature and better processing to improve the texture quality. With these improvements textured piezoelectric ceramics will be viable options for medical ultrasound, actuators, and sonar applications because of their ease of processing, compositional homogeneity, and potentially lower cost than single crystal. PMID:19894807

  2. Part 1. Application of CVD-yttria for the protection of SCS-6 silicon carbide fibers in a reactively sintered nickel aluminide matrix composite. Part 2. CVC pyrolysis studies of various 1,3-substituted 1,3-disilacyclobutanes and application as single-source CVD precursors to silicon carbide

    SciTech Connect

    Larkin, D.J.

    1991-01-01

    A CVD process was developed for coating Textron-Avco SCS-6 SiC fiber with yttria, examining various potential Y[sub 2]O[sub 3] CVD precursors. The coated fibers were incorporated into a nickel aluminide (Ni[sub 3]Al) matrix by reactive sintering, with yttria affording protection from the known SiC + 2Ni [yields] Ni[sub 2]Si + C degradation process. The SiC/Ni[sub 3]Al composites, before and after annealing at 1000[degree]C for up to 100 h, were studied by using SEM and EMPA to determine the extent of reaction. Exception for certain portions of the fibers that were inadequately coated with yttria, complete protection of the fibers was indicated. Low-pressure chemical vapor deposition (LPCVD) of silicon carbide on Si(100) was investigated between 700 and 1100[degree]C at ca. 1.0 torr total pressure using a flow or argon as a carrier gas in a cold-wall total pressure using a flow of argon as a carrier gas in a cold-wall LPCVD system. The gaseous byproducts were determined for each compound, surface and cross sectional morphology was determined and film composition and crystallinity were monitored as a function of deposition temperature. These silicon carbide coatings exhibited preferred crystal growth in the SiC(111) which was quantified for two such coatings via a texture study.

  3. 1,3,5-Trinitrobenzene

    Integrated Risk Information System (IRIS)

    1,3,5 - Trinitrobenzene ; CASRN 99 - 35 - 4 Human health assessment information on a chemical substance is included in the IRIS database only after a comprehensive review of toxicity data , as outlined in the IRIS assessment development process . Sections I ( Health Hazard Assessments for Noncarcino

  4. 5-Oxatricyclo[5.1.0.0(1,3)]octan-4-one, containing an enantiomorph and a racemate and not two polymorphs, is another example of a composite crystal.

    PubMed

    Herbstein, Frank H

    2003-04-01

    This new example of a composite crystal adds to the small number previously reported among inorganic and molecular materials. Revision of the nomenclature used allows more fruitful comparison with the precedents. PMID:12657822

  5. Glass-windowed ultrasound transducers.

    PubMed

    Yddal, Tostein; Gilja, Odd Helge; Cochran, Sandy; Postema, Michiel; Kotopoulis, Spiros

    2016-05-01

    In research and industrial processes, it is increasingly common practice to combine multiple measurement modalities. Nevertheless, experimental tools that allow the co-linear combination of optical and ultrasonic transmission have rarely been reported. The aim of this study was to develop and characterise a water-matched ultrasound transducer architecture using standard components, with a central optical window larger than 10 mm in diameter allowing for optical transmission. The window can be used to place illumination or imaging apparatus such as light guides, miniature cameras, or microscope objectives, simplifying experimental setups. Four design variations of a basic architecture were fabricated and characterised with the objective to assess whether the variations influence the acoustic output. The basic architecture consisted of a piezoelectric ring and a glass disc, with an aluminium casing. The designs differed in piezoelectric element dimensions: inner diameter, ID=10 mm, outer diameter, OD=25 mm, thickness, TH=4 mm or ID=20 mm, OD=40 mm, TH=5 mm; glass disc dimensions OD=20-50 mm, TH=2-4 mm; and details of assembly. The transducers' frequency responses were characterised using electrical impedance spectroscopy and pulse-echo measurements, the acoustic propagation pattern using acoustic pressure field scans, the acoustic power output using radiation force balance measurements, and the acoustic pressure using a needle hydrophone. Depending on the design and piezoelectric element dimensions, the resonance frequency was in the range 350-630 kHz, the -6 dB bandwidth was in the range 87-97%, acoustic output power exceeded 1 W, and acoustic pressure exceeded 1 MPa peak-to-peak. 3D stress simulations were performed to predict the isostatic pressure required to induce material failure and 4D acoustic simulations. The pressure simulations indicated that specific design variations could sustain isostatic pressures up to 4.8 MPa.The acoustic simulations were able to

  6. Single crystal cylinder transducers for sonar applications

    NASA Astrophysics Data System (ADS)

    Robinson, Harold; Stevens, Gerald; Buffman, Martin; Powers, James

    2005-04-01

    A segmented cylinder transducer constructed of single crystal lead magnesium niobate-lead titanate (PMN-PT) has been under development at NUWC and EDO Corporation for several years. The purpose of this development was to provide an extremely compact, high power broadband source. By virtue of their extraordinary material properties, ferroelectric single crystals are the ideal transduction material for developing such compact broadband systems. This presentation shall review the evolution of the transducer design as well as present the results of a successful in-water test conducted at NUWC in October of 2003. It shall be shown that design changes intended to eliminate spurious modes limiting the transducer bandwidth first observed in 2002 were successful, resulting in a transducer with a clean frequency response and an effective coupling factor of 0.85. The measured transducer admittance was in nearly exact agreement with theoretical predictions. The NUWC in-water tests demonstrated that the single crystal cylinder achieved an admittance bandwidth (based on the Stansfield criterion) of over 100%, while the tuned power factor was 0.8 or more over 2.5 octaves of frequency. Additionally, the transducer produced 12 dB higher source levels than a similarly sized PZT transducer. [Work sponsored by DARPA.

  7. Low power consumption current transducer

    NASA Technical Reports Server (NTRS)

    Mclyman, W. T. (Inventor)

    1989-01-01

    A low power consumption current transducer utilizes a saturable core reactor which includes a pair of opposed gate windings and a control winding. The control winding of the saturable reactor is arranged to receive the current to be measured. A square wave generator is connected to the gate winding of the transformer connected across the square wave generator and the secondary connected in series with the gate windings of the reactor. A full wave rectifier is connected to the gate windings and a resistor is connected across the rectifier to provide a DC voltage to cross it representative of the current flow through the control winding. A DC power supply is provided to supply power to the square wave voltage source. A diode is connected between each end of the primary winding of the transformer and one polarity of the DC power supply to commutate the reactive current resulting from the counter emf generated in the reactor back to the DC supply to eliminate potentially damaging reactive voltage spikes which would otherwise appear at the output of the square wave generator and conserve energy.

  8. Seismic transducer modeling using ABAQUS

    SciTech Connect

    Stephen R. Novascone

    2004-05-01

    A seismic transducer, known as an orbital vibrator, consists of a rotating imbalance driven by an electric motor. When suspended in a liquid-filled wellbore, vibrations of the device are coupled to the surrounding geologic media. In this mode, an orbital vibrator can be used as an efficient rotating dipole source for seismic imaging. Alternately, the motion of an orbital vibrator is affected by the physical properties of the surrounding media. From this point of view, an orbital vibrator can be used as a stand-alone sensor. The reaction to the surroundings can be sensed and recorded by geophones inside the orbital vibrator. These reactions are a function of the media’s physical properties such as modulus, damping, and density, thereby identifying the rock type. This presentation shows how the orbital vibrator and surroundings were modeled with an ABAQUS acoustic FEM. The FEM is found to compare favorably with theoretical predictions. A 2D FEM and analytical model are compared to an experimental data set. Each model compares favorably with the data set.

  9. Nanomaterial-based biosensors using dual transducing elements for solution phase detection.

    PubMed

    Li, Ning; Su, Xiaodi; Lu, Yi

    2015-05-01

    Biosensors incorporating nanomaterials have demonstrated superior performance compared to their conventional counterparts. Most reported sensors use nanomaterials as a single transducer of signals, while biosensor designs using dual transducing elements have emerged as new approaches to further improve overall sensing performance. This review focuses on recent developments in nanomaterial-based biosensors using dual transducing elements for solution phase detection. The review begins with a brief introduction of the commonly used nanomaterial transducers suitable for designing dual element sensors, including quantum dots, metal nanoparticles, upconversion nanoparticles, graphene, graphene oxide, carbon nanotubes, and carbon nanodots. This is followed by the presentation of the four basic design principles, namely Förster Resonance Energy Transfer (FRET), Amplified Fluorescence Polarization (AFP), Bio-barcode Assay (BCA) and Chemiluminescence (CL), involving either two kinds of nanomaterials, or one nanomaterial and an organic luminescent agent (e.g. organic dyes, luminescent polymers) as dual transducers. Biomolecular and chemical analytes or biological interactions are detected by their control of the assembly and disassembly of the two transducing elements that change the distance between them, the size of the fluorophore-containing composite, or the catalytic properties of the nanomaterial transducers, among other property changes. Comparative discussions on their respective design rules and overall performances are presented afterwards. Compared with the single transducer biosensor design, such a dual-transducer configuration exhibits much enhanced flexibility and design versatility, allowing biosensors to be more specifically devised for various purposes. The review ends by highlighting some of the further development opportunities in this field. PMID:25763412

  10. A solid-state phase-insensitive ultrasonic transducer

    NASA Technical Reports Server (NTRS)

    Heyman, J. S.

    1979-01-01

    Photoconductive acoustoelectric transducer (AET) functions as phase-insensitive ultrasonic transducer. Device is easy to use and requires no additional noisy components such as light or thermal source.

  11. Hybrid piezoelectric energy harvesting transducer system

    NASA Technical Reports Server (NTRS)

    Xu, Tian-Bing (Inventor); Jiang, Xiaoning (Inventor); Su, Ji (Inventor); Rehrig, Paul W. (Inventor); Hackenberger, Wesley S. (Inventor)

    2008-01-01

    A hybrid piezoelectric energy harvesting transducer system includes: (a) first and second symmetric, pre-curved piezoelectric elements mounted separately on a frame so that their concave major surfaces are positioned opposite to each other; and (b) a linear piezoelectric element mounted separately on the frame and positioned between the pre-curved piezoelectric elements. The pre-curved piezoelectric elements and the linear piezoelectric element are spaced from one another and communicate with energy harvesting circuitry having contact points on the frame. The hybrid piezoelectric energy harvesting transducer system has a higher electromechanical energy conversion efficiency than any known piezoelectric transducer.

  12. A proposed magnetic digital temperature transducer, volume 1

    NASA Technical Reports Server (NTRS)

    Collier, T. E.; Tchernev, D. I.; Hartwig, W. H.

    1972-01-01

    A study has been made of the feasibility of using the discontinuous permeability versus temperature characteristics of some magnetic materials for a digital temperature transducer and a thermally controlled ON-OFF switch. Simple logic converts the number of output pulse to a digital word recognizable by the system. Efforts have been concentrated on materials with Curie temperatures between 0 and 100 C. One compound has the composition Mn(5-x)Fe(x)Ge3 where the amount of iron determines the transition temperature. The other compound is Ni-Zn ferrite and has the compositon Ni(1-x)Zn(x)Fe(1.95)O4 where the nickel: zinc ratio determines the transition temperature. A detailed report of materials prepared is presented. Toroidal inductors of the material have been constructed and the change in inductance with temperature measured. In view of these initial measurements, it is felt that a transducer utilizing the permeability versus temperature characteristics of these materials has promise as a reliable and sensitive solid state digital temperature transducer.

  13. Performance of Spherically Focused Air-Coupled Ultrasonic Transducers

    NASA Astrophysics Data System (ADS)

    Chimenti, D. E.; Song, Junho

    2007-03-01

    This paper reports the development, testing, and performance evaluation of spherically focused capacitive air-coupled ultrasonic transducers 1 and 5 cm in diameter. A flexible micro-machined copper/polyimide backplate permits a conformal fit to a spherically shaped fixture, forming the rear capacitor plate. A spherically deformed 6-μm aluminized Mylar foil forms the front capacitor plate, completing the transducer. The device's frequency spectrum is centered near 800 kHz with -6dB points at about 400 and 1200 kHz. The device's focal-plane behavior is successfully modeled theoretically as a focused piston radiator. The imaging and defect detection capabilities of the new transducer are demonstrated in a series of critical tests: a 250-μm wire is easily imaged in a confocal geometry with a second device. Composite, honeycomb, and wood samples are imaged in through-transmission C-scans, showing internal defects. A printed circuit board is imaged, showing features as small as 200-μm.

  14. Fundamentals of heat measurement. [heat flux transducers

    NASA Technical Reports Server (NTRS)

    Gerashchenko, O. A.

    1979-01-01

    Various methods and devices for obtaining experimental data on heat flux density over wide ranges of temperature and pressure are examined. Laboratory tests and device fabrication details are supplemented by theoretical analyses of heat-conduction and thermoelectric effects, providing design guidelines and information relevant to further research and development. A theory defining the measure of correspondence between transducer signal and the measured heat flux is established for individual (isolated) heat flux transducers subject to space and time-dependent loading. An analysis of the properties of stacked (series-connected) transducers of various types (sandwich-type, plane, and spiral) is used to derive a similarity theory providing general governing relationships. The transducers examined are used in 36 types of derivative devices involving direct heat loss measurements, heat conduction studies, radiation pyrometry, calorimetry in medicine and industry and nuclear reactor dosimetry.

  15. Improved transducer for squeeze-film bearings

    NASA Technical Reports Server (NTRS)

    Hoogenbloom, L.

    1971-01-01

    Transducer amplifies vibrations produced by piezoelectric drivers, creating greater amplitudes than were possible with direct drive devices. Drivers isolated from bearing surfaces result in bearings with high axial load capacity and stiffness, thus, wear on ceramic cylinders is reduced.

  16. Portable high precision pressure transducer system

    DOEpatents

    Piper, Thomas C.; Morgan, John P.; Marchant, Norman J.; Bolton, Steven M.

    1994-01-01

    A high precision pressure transducer system for checking the reliability of a second pressure transducer system used to monitor the level of a fluid confined in a holding tank. Since the response of the pressure transducer is temperature sensitive, it is continually housed in an battery powered oven which is configured to provide a temperature stable environment at specified temperature for an extended period of time. Further, a high precision temperature stabilized oscillator and counter are coupled to a single board computer to accurately determine the pressure transducer oscillation frequency and convert it to an applied pressure. All of the components are powered by the batteries which during periods of availability of line power are charged by an on board battery charger. The pressure readings outputs are transmitted to a line printer and a vacuum florescent display.

  17. AUTOMATIC CALIBRATING SYSTEM FOR PRESSURE TRANSDUCERS

    DOEpatents

    Amonette, E.L.; Rodgers, G.W.

    1958-01-01

    An automatic system for calibrating a number of pressure transducers is described. The disclosed embodiment of the invention uses a mercurial manometer to measure the air pressure applied to the transducer. A servo system follows the top of the mercury column as the pressure is changed and operates an analog- to-digital converter This converter furnishes electrical pulses, each representing an increment of pressure change, to a reversible counterThe transducer furnishes a signal at each calibration point, causing an electric typewriter and a card-punch machine to record the pressure at the instant as indicated by the counter. Another counter keeps track of the calibration points so that a number identifying each point is recorded with the corresponding pressure. A special relay control system controls the pressure trend and programs the sequential calibration of several transducers.

  18. Portable high precision pressure transducer system

    DOEpatents

    Piper, T.C.; Morgan, J.P.; Marchant, N.J.; Bolton, S.M.

    1994-04-26

    A high precision pressure transducer system is described for checking the reliability of a second pressure transducer system used to monitor the level of a fluid confined in a holding tank. Since the response of the pressure transducer is temperature sensitive, it is continually housed in an battery powered oven which is configured to provide a temperature stable environment at specified temperature for an extended period of time. Further, a high precision temperature stabilized oscillator and counter are coupled to a single board computer to accurately determine the pressure transducer oscillation frequency and convert it to an applied pressure. All of the components are powered by the batteries which during periods of availability of line power are charged by an on board battery charger. The pressure readings outputs are transmitted to a line printer and a vacuum fluorescent display. 2 figures.

  19. A magnifying scratch-gage force transducer

    NASA Technical Reports Server (NTRS)

    Scott, C. E.

    1969-01-01

    Single-component scratch-gage transducer incorporates a unique motion magnification scheme to increase the magnitude of the load measuring scratch approximately 15 times over that of conventional models. It is small, load carrying and high in natural frequency.

  20. Micromachined Tunneling Displacement Transducers for Physical Sensors

    NASA Technical Reports Server (NTRS)

    Kenny, T. W.; Kaiser, W. J.; Podosek, J. A.; Rockstad, H. K.; Reynolds, J. K.; Vote, E. C.

    1993-01-01

    We have designed and constructed a series of tunneling sensors which take advantage of the extreme position sensitivity of electron tunneling. In these sensors, a tunneling displacement transducer, based on scanning tunneling microscopy principles, is used to detect the signal-induced motion of a sensor element. Through the use of high-resonant frequency mechanical elements for the transducer, sensors may be constructed which offer wide bandwidth, and are robust and easily operated. Silicon micromachining may be used to fabricate the transducer elements, allowing integration of sensor and control electronics. Examples of tunneling accelerometers and infrared detectors will be discussed. In each case, the use of the tunneling transducer allows miniaturization of the sensor as well as enhancement of the sensor performance.

  1. Guided wave applications of piezocomposite transducers

    SciTech Connect

    Meyer, P.A.; Rose, J.L.

    1996-12-31

    The majority of ultrasonic nondestructive testing applications in use today utilize longitudinal wave techniques. These are very effective for flaw detection and thickness measurement in scanning applications. In sheet and tube type materials, however, a more rapid technique has been developed utilizing Guided Wave Inspection. This method is capable of interrogating large areas of the material without extensive transducer scanning. An important requirement in this method is the ability to utilize relatively broad bandwidth transducers in the test. This paper presents the concepts on which Guided Wave Inspection is based as well as piezocomposite transducer incorporate a combination of piezoelectric ceramics and polymers to enhance the ultrasonic performance of the device. Additionally, the transducer can be designed to match to non-planar surfaces increasing its versatility when a difficult shape is involved.

  2. Development of an inherently digital transducer

    NASA Technical Reports Server (NTRS)

    Richard, R. R.

    1972-01-01

    The term digital transducer normally implies the combination of conventional analog sensors with encoders or analog-to-digital converters. Because of the objectionable characteristics of most digital transducers, a program was instituted to investigate the possibility of producing a transducer that is inherently digital, instead of a transducer that is digital in the usual sense. Such a device would have improved accuracy and reliability and would have reduced power and bulk requirements because two processes, sensing and conditioning, would be combined into one processes. A Curie-point-temperature sensor is described that represents realization of the stated goal. Also, a metal-insulator semiconductor is described that does not conform precisely to the program goals but that appears to have applications as a new and interesting transduction device.

  3. Development of a tethered satellite force transducer

    NASA Astrophysics Data System (ADS)

    Rhew, Ray D.

    The SEDS (Small Expendable Deployer System)/Delta II is a demonstration flight of a tethered satellite deployer system. The satellite or end mass payload, which is deployed and tethered to the Delta II rocket, is instrumented to determine its dynamics during deployment. A three-component force transducer or strain-gage balance was developed to measure tether tension on the end-mass side of the tether. The transducer was designed to measure tensions up to 20N in each direction and resolve tensions as low as 0.002N. In addition, the transducer was required to withstand the shock, vibration, and temperature excursions of the mission. The development of the transducer from design to testing and integration is discussed.

  4. Ultrasonic transducer for extreme temperature environments

    DOEpatents

    Light, Glenn M.; Cervantes, Richard A.; Alcazar, David G.

    1993-03-23

    An ultrasonic piezoelectric transducer that is operable in very high and very low temperatures. The transducer has a dual housing structure that isolates the expansion and contraction of the piezoelectric element from the expansion and contraction of the housing. Also, the internal components are made from materials having similar coefficients of expansion so that they do not interfere with the motion of the piezoelectric element.

  5. High energy, low frequency, ultrasonic transducer

    DOEpatents

    Brown, Albert E.

    2000-01-01

    A wide bandwidth, ultrasonic transducer to generate nondispersive, extensional, pulsed acoustic pressure waves into concrete reinforced rods and tendons. The wave propagation distance is limited to double the length of the rod. The transducer acoustic impedance is matched to the rod impedance for maximum transfer of acoustic energy. The efficiency of the transducer is approximately 60 percent, depending upon the type of active elements used in the transducer. The transducer input energy is, for example, approximately 1 mJ. Ultrasonic reflections will occur at points along the rod where there are changes of one percent of a wavelength in the rod diameter. A reduction in the rod diameter will reflect a phase reversed echo, as compared with the reflection from an incremental increase in diameter. Echo signal processing of the stored waveform permits a reconstruction of those echoes into an image of the rod. The ultrasonic transducer has use in the acoustic inspection of long (40+foot) architectural reinforcements and structural supporting members, such as in bridges and dams.

  6. Resonant capacitive MEMS acoustic emission transducers

    NASA Astrophysics Data System (ADS)

    Ozevin, D.; Greve, D. W.; Oppenheim, I. J.; Pessiki, S. P.

    2006-12-01

    We describe resonant capacitive MEMS transducers developed for use as acoustic emission (AE) detectors, fabricated in the commercial three-layer polysilicon surface micromachining process (MUMPs). The 1 cm square device contains six independent transducers in the frequency range between 100 and 500 kHz, and a seventh transducer at 1 MHz. Each transducer is a parallel plate capacitor with one plate free to vibrate, thereby causing a capacitance change which creates an output signal in the form of a current under a dc bias voltage. With the geometric proportions we employed, each transducer responds with two distinct resonant frequencies. In our design the etch hole spacing was chosen to limit squeeze film damping and thereby produce an underdamped vibration when operated at atmospheric pressure. Characterization experiments obtained by capacitance and admittance measurements are presented, and transducer responses to physically simulated AE source are discussed. Finally, we report our use of the device to detect acoustic emissions associated with crack initiation and growth in weld metal.

  7. Absolute calibration technique for broadband ultrasonic transducers

    NASA Technical Reports Server (NTRS)

    Yost, William T. (Inventor); Cantrell, John H. (Inventor)

    1994-01-01

    Calibrating an ultrasonic transducer can be performed with a reduced number of calculations and testing. A wide-band pulser is connected to an ultrasonic transducer under test to generate ultrasonic waves in a liquid. A single frequency is transmitted to the electrostatic acoustic transducer (ESAT) and the voltage change produced is monitored. Then a broadband ultrasonic pulse is generated by the ultrasonic transducer and received by the ESAT. The output of the ESAT is amplified and input to a digitized oscilloscope for fast Fourier transform. The resulting plot is normalized with the monitored signal from the single frequency pulse. The plot is then corrected for characteristics of the membrane and diffraction effects. The transfer function of the final plot is determined. The transfer function gives the final sensitivity of the ultrasonic transducer as a function of frequency. The advantage of the system is the speed of calibrating the transducer by a reduced number of measurements and removal of the membrane and diffraction effects.

  8. A flexible piezoelectric transducer design for efficient generation and reception of ultrasonic Lamb waves.

    PubMed

    Gachagan, Anthony; Hayward, Gordon; Banks, Robert

    2005-07-01

    This paper describes the development of a flexible piezoelectric transducer for the generation and detection of ultrasonic symmetrical Lamb waves in plate-like structures. This piezoplatelet transducer structure comprises an array of miniature piezoceramic plates embedded within a soft setting polymer filler material, combining the efficiency of the active piezoceramic phase with a degree of flexibility, which is a function of the platelet/polymer dimensions. For many condition-monitoring applications, the generation of ultrasonic Lamb waves is often appropriate, and this was achieved by incorporating interdigital design techniques via the transducer electrode pattern. The performance of the piezoplatelet transducer structure was evaluated using a combination of linear systems and finite-element modeling, substantiated by experimental results. Importantly, the transducer is shown to operate as an ensemble of platelets, each operating in the thickness mode and well decoupled from neighboring piezoelectric elements. Using this transducer configuration, an unimodal s1 Lamb wave, at 1.45 MHz, has been generated and detected in a 3-mm thick steel plate. Furthermore, a propagation distance of almost 1 m was recorded for s0 Lamb wave generation/detection in a fiber-reinforced composite plate. PMID:16212257

  9. 21 CFR 870.2860 - Heart sound transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Heart sound transducer. 870.2860 Section 870.2860...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2860 Heart sound transducer. (a) Identification. A heart sound transducer is an external transducer that exhibits a change...

  10. 21 CFR 870.2860 - Heart sound transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Heart sound transducer. 870.2860 Section 870.2860...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2860 Heart sound transducer. (a) Identification. A heart sound transducer is an external transducer that exhibits a change...

  11. 21 CFR 870.2860 - Heart sound transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Heart sound transducer. 870.2860 Section 870.2860...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2860 Heart sound transducer. (a) Identification. A heart sound transducer is an external transducer that exhibits a change...

  12. 21 CFR 870.2860 - Heart sound transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Heart sound transducer. 870.2860 Section 870.2860...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2860 Heart sound transducer. (a) Identification. A heart sound transducer is an external transducer that exhibits a change...

  13. 21 CFR 870.2860 - Heart sound transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Heart sound transducer. 870.2860 Section 870.2860...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Monitoring Devices § 870.2860 Heart sound transducer. (a) Identification. A heart sound transducer is an external transducer that exhibits a change...

  14. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  15. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  16. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  17. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  18. 21 CFR 870.2890 - Vessel occlusion transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Vessel occlusion transducer. 870.2890 Section 870... transducer. (a) Identification. A vessel occlusion transducer is a device used to provide an electrical..., sound, and ultrasonic transducers. (b) Classification. Class II (performance standards)....

  19. Microfabrication of stacks of acoustic matching layers for 15 MHz ultrasonic transducers.

    PubMed

    Manh, Tung; Nguyen, Anh-Tuan Thai; Johansen, Tonni F; Hoff, Lars

    2014-02-01

    This paper presents a novel method used to manufacture stacks of multiple matching layers for 15 MHz piezoelectric ultrasonic transducers, using fabrication technology derived from the MEMS industry. The acoustic matching layers were made on a silicon wafer substrate using micromachining techniques, i.e., lithography and etch, to design silicon and polymer layers with the desired acoustic properties. Two matching layer configurations were tested: a double layer structure consisting of a silicon-polymer composite and polymer and a triple layer structure consisting of silicon, composite, and polymer. The composite is a biphase material of silicon and polymer in 2-2 connectivity. The matching layers were manufactured by anisotropic wet etch of a (110)-oriented Silicon-on-Insulator wafer. The wafer was etched by KOH 40 wt%, to form 83 μm deep and 4.5mm long trenches that were subsequently filled with Spurr's epoxy, which has acoustic impedance 2.4 MRayl. This resulted in a stack of three layers: The silicon substrate, a silicon-polymer composite intermediate layer, and a polymer layer on the top. The stacks were bonded to PZT disks to form acoustic transducers and the acoustic performance of the fabricated transducers was tested in a pulse-echo setup, where center frequency, -6 dB relative bandwidth and insertion loss were measured. The transducer with two matching layers was measured to have a relative bandwidth of 70%, two-way insertion loss 18.4 dB and pulse length 196 ns. The transducers with three matching layers had fractional bandwidths from 90% to 93%, two-way insertion loss ranging from 18.3 to 25.4 dB, and pulse lengths 326 and 446 ns. The long pulse lengths of the transducers with three matching layers were attributed to ripple in the passband. PMID:24041498

  20. Electric field effect of relaxor ferroelectric (1 ‑ x)Pb(Mg1/3Nb2/3)O3–xPbTiO3 crystals near morphotropic phase boundary composition probed by Brillouin scattering

    NASA Astrophysics Data System (ADS)

    Aftabuzzaman, Md; Kojima, Seiji

    2016-07-01

    The relaxor ferroelectric (1 ‑ x)Pb(Mg1/3Nb2/3)O3–xPbTiO3 (x = 0.30, PMN–30PT) single crystal was studied under the zero field and the externally applied dc electric field by using micro-Brillouin scattering and dielectric spectroscopies over a wide temperature range of 303–773 K. The noticeable thermal hysteresis of longitudinal acoustic (LA) shift (νB) was observed between zero field heating and zero field cooling processes. Under the electric field of 0.5 kV/cm along the [001] axis, the LA mode splitting was observed in νB due to the coexistence of ferroelectric macrodomain and nanodomain states caused by the random field, and in dielectric measurements the monoclinic (M) and tetragonal phases were appeared between rhombohedral and cubic phases. The LA mode splitting and M phase disappeared under the field of 1.0 kV/cm. The electric field dependence of LA velocity was studied at 304 K. The critical end point of the PMN–30PT single crystal was investigated.

  1. Review on Acoustic Transducers for Resonant Ultrasound Spectroscopy

    NASA Astrophysics Data System (ADS)

    Nakamura, N.; Ogi, H.; Hirao, M.

    2015-08-01

    Determination of elastic constants using resonant ultrasound spectroscopy requires transducers that can measure resonance frequencies accurately and identify the vibrational mode of each resonance frequency. We developed three transducers, namely an electromagnetic acoustic transducer, a tripod piezoelectric transducer coupled with a laser Doppler interferometer, and an antenna transmission transducer, for use with various materials and in different measurement circumstances. Their capability in resonant ultrasound spectroscopy and their applications are described.

  2. Advanced Bode Plot Techniques for Ultrasonic Transducers

    NASA Astrophysics Data System (ADS)

    DeAngelis, D. A.; Schulze, G. W.

    The Bode plot, displayed as either impedance or admittance versus frequency, is the most basic test used by ultrasonic transducer designers. With simplicity and ease-of-use, Bode plots are ideal for baseline comparisons such as spacing of parasitic modes or impedance, but quite often the subtleties that manifest as poor process control are hard to interpret or are nonexistence. In-process testing of transducers is time consuming for quantifying statistical aberrations, and assessments made indirectly via the workpiece are difficult. This research investigates the use of advanced Bode plot techniques to compare ultrasonic transducers with known "good" and known "bad" process performance, with the goal of a-priori process assessment. These advanced techniques expand from the basic constant voltage versus frequency sweep to include constant current and constant velocity interrogated locally on transducer or tool; they also include up and down directional frequency sweeps to quantify hysteresis effects like jumping and dropping phenomena. The investigation focuses solely on the common PZT8 piezoelectric material used with welding transducers for semiconductor wire bonding. Several metrics are investigated such as impedance, displacement/current gain, velocity/current gain, displacement/voltage gain and velocity/voltage gain. The experimental and theoretical research methods include Bode plots, admittance loops, laser vibrometry and coupled-field finite element analysis.

  3. Piezoelectric transducer design via multiobjective optimization.

    PubMed

    Fu, B; Hemsel, T; Wallaschek, J

    2006-12-22

    The design of piezoelectric transducers is usually based on single-objective optimization only. In most practical applications of piezoelectric transducers, however, there exist multiple design objectives that often are contradictory to each other by their very nature. It is impossible to find a solution at which each objective function gets its optimal value simultaneously. Our design approach is to first find a set of Pareto-optimal solutions, which can be considered to be best compromises among multiple design objectives. Among these Pareto-optimal solutions, the designer can then select the one solution which he considers to be the best one. In this paper we investigate the optimal design of a Langevin transducer. The design problem is formulated mathematically as a constrained multiobjective optimization problem. The maximum vibration amplitude and the minimum electrical input power are considered as optimization objectives. Design variables involve continuous variables (dimensions of the transducer) and discrete variables (the number of piezoelectric rings and material types). In order to formulate the optimization problem, the behavior of piezoelectric transducers is modeled using the transfer matrix method based on analytical models. Multiobjective evolutionary algorithms are applied in the optimization process and a set of Pareto-optimal designs is calculated. The optimized results are analyzed and the preferred design is determined. PMID:16814826

  4. FL V1.3

    2009-08-03

    A library of utility classes for computer vision. Contains implementations of various well-known image processing techniques, such as interest point operators and region descriptors. Includes interfaces to various libraries for image and video I/O, as well as an interface to LAPACK/BLAS. FL was developed at the University of Illinois, Urbana-Champaign (UIUC) and released under an open source license. Version 1.2 was a maintenance release provided by SNL under the LGPL license. Version 1.3 is amore » maintenance release, containing the following changes: - Improved image format handling. Now handles strided and planar memory layouts and a wider range of pixel formats. - Improved image file I/O, including better support for metadata, a wider range of stored pixel types, and a couple of new file formats. - Improvements to DOG and SIFT, and efficiency improvements in low-level convolution. - Improvements to networking, including a generic TCP listener. - Various improvements to numerical processing. The HISTORY file included in the distribution contains a more detailed description of the changes.« less

  5. FL V1.3

    SciTech Connect

    Rothganger, Frederick

    2009-08-03

    A library of utility classes for computer vision. Contains implementations of various well-known image processing techniques, such as interest point operators and region descriptors. Includes interfaces to various libraries for image and video I/O, as well as an interface to LAPACK/BLAS. FL was developed at the University of Illinois, Urbana-Champaign (UIUC) and released under an open source license. Version 1.2 was a maintenance release provided by SNL under the LGPL license. Version 1.3 is a maintenance release, containing the following changes: - Improved image format handling. Now handles strided and planar memory layouts and a wider range of pixel formats. - Improved image file I/O, including better support for metadata, a wider range of stored pixel types, and a couple of new file formats. - Improvements to DOG and SIFT, and efficiency improvements in low-level convolution. - Improvements to networking, including a generic TCP listener. - Various improvements to numerical processing. The HISTORY file included in the distribution contains a more detailed description of the changes.

  6. Optimization of matching layer design for medical ultrasonic transducer

    NASA Astrophysics Data System (ADS)

    Zhu, Jie

    This thesis work contains two major parts. In the first part, ultrasonic wave propagation in multilayer structure is investigated. Delaminations between ceramic and electrode layers in multilayer capacitors and multilayer actuators are common defects, which are difficult to detect using traditional ultrasonic imaging method if the size is smaller than 50 microns in diameter. The T-Matrix method is used to treat wave attenuation in periodic structures with alternating ceramic and electrode layers. Multiple penny-shaped delaminations are assumed perpendicular to the incidence wave, and the forward scattering amplitude of the wave from delaminations is calculated by substituting the average effective crack opening displacement into the scattered wave displacement. The effective phase velocity, wave amplitude and the attenuation coefficient have been calculated for different crack densities. The results provide a theoretical base for potential attenuation based ultrasonic non-destructive evaluation (NDE) method. The second part is a study on matching layers. Matching layers are crucial components in ultrasonic transducers for medical imaging. Without proper matching layers, large acoustic impedance mismatch between piezoelectric resonator and the human body tissue will cause most of the ultrasound energy to be reflected at the interface. For a given frequency, the matching layer thickness should be one quarter of the wavelength and its acoustic impedance should be the geometric mean of the acoustic impedances of piezoelectric material and the imaging body. There are no natural materials that can precisely meet such requirements. Therefore, solid particle/polymer composites are commonly used as matching layer materials. The acoustic impedance of such composites is generally in the range of 2-15 MRayls. It is a routine task to make such composite for low frequency transducers, but for transducers with operating frequency higher than 40 MHz, the powder size must be sub

  7. Design and simulation of an ultrasonic transducer

    NASA Astrophysics Data System (ADS)

    Yu, Zhenxian; Shi, Yanru; Hsu, Hung-Yao; Kong, Lingxue

    2005-12-01

    This paper presents a novel ultrasonic transducer which can be used as a liquid ejector to release drug. The ultrasonic transducer is based on the design of a flextensional transducer, which is composed of interdigital piezoelectric rings and a vibration membrane. The device works at an axisymmetric resonant mode to produce maximum amplitude at the center of the vibration membrane in axial direction. For the usage of multi piezoelectric rings, the flexural plate waves can be generated by applying two out-of-phase signals. The power consumption is of primary importance in the design of this device and the usage of single-ring or multi-ring piezoelectric material instead of bulk piezo material can therefore reduce the power consumption. An optimum working frequency, at which least power is required by the device, can be found by the piezoelectric, coupled field capability of the ANSYS/Multiphysics product.

  8. Rapid prototyping fabrication of focused ultrasound transducers.

    PubMed

    Kim, Yohan; Maxwell, Adam D; Hall, Timothy L; Xu, Zhen; Lin, Kuang-Wei; Cain, Charles A

    2014-09-01

    Rapid prototyping (RP) fabrication techniques are currently widely used in diverse industrial and medical fields, providing substantial advantages in development time and costs in comparison to more traditional manufacturing processes. This paper presents a new method for the fabrication of high-intensity focused ultrasound transducers using RP technology. The construction of a large-aperture hemispherical transducer designed by computer software is described to demonstrate the process. The transducer was conceived as a modular design consisting of 32 individually focused 50.8-mm (2-in) PZT-8 element modules distributed in a 300-mm hemispherical scaffold with a geometric focus of 150 mm. The entire structure of the array, including the module housings and the hemispherical scaffold was fabricated through a stereolithography (SLA) system using a proprietary photopolymer. The PZT elements were bonded to the lenses through a quarter-wave tungsten-epoxy matching layer developed in-house specifically for this purpose. Modules constructed in this manner displayed a high degree of electroacoustic consistency, with an electrical impedance mean and standard deviation of 109 ± 10.2 Ω for the 32 elements. Time-of-flight measurements for individually pulsed modules mounted on the hemispherical scaffold showed that all pulses arrived at the focus within a 350 ns range, indicating a good degree of element alignment. Pressure profile measurements of the fully assembled transducer also showed close agreement with simulated results. The measured focal beam FWHM dimensions were 1.9 × 4.0 mm (1.9 × 3.9 mm simulated) in the transversal and axial directions respectively. Total material expenses associated with the construction of the transducer were approximately 5000 USD (as of 2011). The versatility and lower fabrication costs afforded by RP methods may be beneficial in the development of complex transducer geometries suitable for a variety of research and clinical applications

  9. Using XBee transducers for wireless data collection

    NASA Astrophysics Data System (ADS)

    Ayars, Eric; Lai, Estella

    2010-07-01

    This article describes how to use XBee transducers to create small and lightweight wireless sensors, which send data to a base station for collection and analysis. Data collection is limited to 10-bit accuracy by the XBee hardware. Depending on the type of XBee used, up to six data channels can be transmitted over a range of up to 15 miles. We describe the technical details of the process using the low-power version of the XBee transducer and a three-axis accelerometer chip.

  10. Ultrasonic transducer with laminated coupling wedge

    DOEpatents

    Karplus, Henry H. B.

    1976-08-03

    An ultrasonic transducer capable of use in a high-temperature environment incorporates a laminated metal coupling wedge including a reflecting edge shaped as a double sloping roof and a transducer crystal backed by a laminated metal sound absorber disposed so as to direct sound waves through the coupling wedge and into a work piece, reflections from the interface between the coupling wedge and the work piece passing to the reflecting edge. Preferably the angle of inclination of the two halves of the reflecting edge are different.

  11. Pressure transducer and system for cryogenic environments

    NASA Technical Reports Server (NTRS)

    Chapman, John J. (Inventor)

    1992-01-01

    A silicon pressure die is bonded to a borosilicate substrate above the pneumatic port. A Wheatstone bridge circuit is formed on the silicon pressure die and has bridge elements of silicon doped with boron to a deposit density level of approximately 1 x 10(exp 19)-10(exp 21) boron/cc. A current source is provided to excite the Wheatstone bridge circuit. In addition, a temperature sensor is provided to provide temperature readings. An array may be formed of the resulting pressure transducers. This unique solution of materials permits operation of a pressure transducer in cryogenic environments.

  12. Mechano-electric optoisolator transducer with hysteresis

    NASA Astrophysics Data System (ADS)

    Ciuruş, I. M.; Dimian, M.; Graur, A.

    2011-01-01

    This article presents a theoretical and experimental study of designing a mechano-electric optoisolator transducer with hysteresis. Our research is centred upon designing transducers on the basis of optical sensors, as photoelectric conversions eliminate the influence of electromagnetic disturbances. Conversion of the rotation/translation motions into electric signals is performed with the help of a LED-photoresistor Polaroid optocoupler. The driver of the optocoupler's transmitter module is an independent current source. The signal conditioning circuit is a Schmitt trigger circuit. The device is designed to be applied in the field of automation and mechatronics.

  13. Planar shear horizontal guided wave inspection of a plate using piezoelectric fiber transducers

    NASA Astrophysics Data System (ADS)

    Soorgee, M. H.; Lissenden, C. J.; Rose, J. L.; Yousefi-Koma, A.

    2013-01-01

    Fundamental Shear Horizontal (SH0) guided waves have been simulated using finite element software in order to locate a crack in a plate structure. Long but narrow piezoelectric fiber composite strips have been considered as transducers to excite and receive SH guided waves. A segmented transducer, which enables piecewise sensing, has been shown by finite element analysis to be capable of locating a tiny through-thickness crack. The main benefits are that SH waves could be used to inspect fluid loaded structures and that it is possible to detect a crack oriented parallel to the wave vector.

  14. Focal Length Controllable Ultrasonic Array Transducer with Adjustable Curvature

    NASA Astrophysics Data System (ADS)

    Kim, Jungsoon; Kim, Moojoon; Ha, Kanglyel

    2012-07-01

    In the underwater imaging field, the control of the focal length of a transducer is very useful. As one of the control methods, we suggested an ultrasonic array transducer with adjustable curvature by using air pressure. The curvature of the transducer was investigated according to the air pressure level in the back space of the transducer. Concave-, planar-, and convex-type transducers were obtained with different air pressure levels. The acoustic fields of the transducer were measured for different shapes of the radiation surface.

  15. 7.5 MHz dual-layer transducer array for 3-D rectilinear imaging.

    PubMed

    Chen, Yuling; Nguyen, Man; Yen, Jesse T

    2011-07-01

    The difficulties associated with fabrication and interconnection have limited the development of 2-D ultrasound transducer arrays with a large number ofelements (>5000). In previous work, we described a 5 MHz center frequency PZT-P[VDF-TrFE] dual-layer transducer that used two perpendicular 1-D arrays for 3-D rectilinear imaging. This design substantially reduces the channel count as well as fabrication complexity, which makes 3-D imaging more realizable. Higher frequencies (>5 MHz) are more commonly used in clinical applications or imaging targets near transducers, such as the breast, carotid and musculoskeletal tissue. In this paper, we present a 7.5 MHz dual-layer transducer array for 3-D rectilinear imaging. A modified acoustic stack model was designed and fabricated. PZT elements were sub-diced to eliminate lateral coupling. This sub-dicing process made the PZT into a 2-2 composite material, which could help improve transducer sensitivity and bandwidth. Full synthetic-aperture 3-D data sets were acquired by interfacing the transducer with a Verasonics data-acquisition system (VDAS). Offline 3-D beamforming was then performed to obtain volumes of a multiwire phantom and a cyst phantom. The generalized coherence factor (GCF) was applied to improve the contrast of cyst images. The measured -6 dB fractional bandwidth of the transducer was 71% with a center frequency of 7.5 MHz. The measured lateral beamwidths were 0.521 mm and 0.482 mm in azimuth and elevation, respectively, compared with a simulated beamwidth of 0.43 mm. PMID:21842584

  16. A 7.5 MHz Dual-Layer Transducer Array for 3-D Rectilinear Imaging

    PubMed Central

    Chen, Yuling; Nguyen, Man; Yen, Jesse T.

    2011-01-01

    The difficulties associated with fabrication and interconnection have limited the development of 2-D ultrasound transducer arrays with a large number of elements (>5000). In previous work, we described a 5 MHz center frequency PZT-P[VDF-TrFE] dual-layer transducer, which used 2 perpendicular 1-D arrays for 3-D rectilinear imaging. This design substantially reduces the channel count as well as fabrication complexity, which makes 3-D imaging more realizable. Higher frequencies (>5MHz) are more commonly used in clinical for imaging targets near transducers such as the breast, carotid, and musculoskeletal. In this paper, we present a 7.5 MHz dual-layer transducer array for 3-D rectilinear imaging. A modified acoustic stack model was designed and fabricated. PZT elements were sub-diced to eliminate lateral coupling. This sub-dicing process made the PZT into a 2–2 composite material, which could help improve transducer sensitivity and bandwidth. Full synthetic aperture 3-D data sets were acquired by interfacing the transducer with a Verasonics data acquisition system (VDAS). Offline 3-D beamforming was then performed to obtain volumes of a multi-wire phantom and a cyst phantom. The generalized coherence factor (GCF) was applied to improve the contrast of cyst images. The measured −6 dB fractional bandwidth of the transducer was 71% with a center frequency of 7.5 MHz. The measured lateral beamwidths were 0.521 mm and 0.482 mm in azimuth and elevation respectively, compared with a simulated beamwidth of 0.43 mm. PMID:21842584

  17. Transducer Joint for Kidney-Stone Ultrasonics

    NASA Technical Reports Server (NTRS)

    Angulo, E. D.

    1983-01-01

    Ultrasonic therapy for kidney stones improved by new way of connecting wire-probe ultrasonic waveguide to transducer. Improved mounting allows joint to last long enough for effective treatment. Sheath and rubber dampers constrain lateral vibration of wire waveguide. Combination of V-shaped mounting groove, sheath, and rubber dampers increases life expectancy of wire 15 times or more.

  18. Electropneumatic transducer automatically limits motor current

    NASA Technical Reports Server (NTRS)

    Lovitt, T. F.

    1966-01-01

    Pneumatic controller regulates the load on a centrifugal freon compressor in a water cooling system, thus limiting the current input to an electric motor driving it. An electromechanical transducer monitoring the motor input current sends out air signals which indicate changes in the current to the pneumatic controller.

  19. In sodium tests of ultrasonic transducers

    SciTech Connect

    Lhuillier, C.; Descombin, O.; Baque, F.; Marchand, B.; Saillant, J. F.

    2011-07-01

    Ultrasonic techniques are seen as suitable candidates for the in-service inspection and for the continuous surveillance of sodium cooled reactors (SFR). These techniques need the development and the qualification of immersed ultrasonic transducers, and materials. This paper presents some developments performed by CEA (DTN and LIST) and AREVA (NDE Solutions), and some results. (authors)

  20. Thermoacoustic power conversion using a piezoelectric transducer.

    PubMed

    Jensen, Carl; Raspet, Richard

    2010-07-01

    The predicted efficiency of a simple thermoacoustic waste heat power conversion device has been investigated as part of a collaborative effort combining a thermoacoustic engine with a piezoelectric transducer. Symko et al. [Microelectron. J. 35, 185-191 (2004)] at the University of Utah built high frequency demonstration engines for this application, and Lynn [ASMDC report, accession number ADA491030 (2008)] at the University of Washington designed and built a high efficiency piezoelectric unimorph transducer for electroacoustic conversion. The design presented in this paper is put forward to investigate the potential of a simple high frequency, air filled, standing wave thermoacoustic device to be competitive with other small generator technologies such as thermoelectric devices. The thermoacoustic generator is simulated using a low-amplitude approximation for thermoacoustics and the acoustic impedance of the transducer is modeled using an equivalent circuit model calculated from the transducer's mechanical and electrical properties. The calculations demonstrate that a device performance of around 10% of Carnot efficiency could be expected from the design which is competitive with currently available thermoelectric generators. PMID:20649205

  1. Ferroelectret non-contact ultrasonic transducers

    NASA Astrophysics Data System (ADS)

    Bovtun, V.; Döring, J.; Bartusch, J.; Beck, U.; Erhard, A.; Yakymenko, Y.

    2007-09-01

    Dielectric and electromechanical properties of the cellular polypropylene ferroelectret films (EMFIT), combining strong piezoelectric response with a low density and softness, evidence their high potential for the air-coupled ultrasonic applications. The disadvantage of the low coupling factor is compensated by the extremely low acoustic impedance, which provides excellent matching to air and promises efficient sound transmission through the air transducer interface. The influence of the electrodes on the electromechanical properties was investigated. Electron beam evaporation technology was adapted to the EMFIT films, and films with both-sided Au and Al electrodes were prepared without reducing or suppressing of the electromechanical properties. Finally, prototype transducers based on the EMFIT films were developed. In spite of the simple construction and absence of matching layers, high sensitivity of the EMFIT transducers was proved in the air-coupled ultrasonic experiment. Amplitude and delay time scanned images of the polyethylene step wedge with holes, obtained in both pulse-echo and transmission modes, demonstrate that non-contact ultrasonic imaging and testing with EMFIT transducers is possible.

  2. Improved Ultrasonic Transducer For Measuring Cryogenic Flow

    NASA Technical Reports Server (NTRS)

    Barkhoudarian, Sarkis

    1991-01-01

    Improved ultrasonic transducer used to measure flow of cryogenic fluid. Includes wedge made nonintrusive by machining it out of bulk material of duct carrying fluid. Skewed surfaces of wedge suppress standing waves, thus reducing ringing and increasing signal-to-noise ratio. Increases accuracy of measurements of times of arrival of ultrasonic pulses, from which times flow inferred.

  3. Broadband, High-Temperature Ultrasonic Transducer

    NASA Technical Reports Server (NTRS)

    Parker, F. Raymond; Winfree, William P.; Barrows, Danny A.

    1995-01-01

    Materials chosen for endurance at high temperatures and acoustic coupling and damping. Acoustic transducer designed to exhibit broad frequency response and to survive temperatures close to melting points of brazing alloys. Attached directly and continuously to hot object monitored ultrasonically: for example, it can be attached to relatively cool spot on workpiece during brazing for taking ultrasonic quality-control measurements.

  4. An IVUS Transducer for Microbubble Therapies

    PubMed Central

    Kilroy, Joseph P.; Patil, Abhay V.; Rychak, Joshua J.; Hossack, John A.

    2014-01-01

    There is interest in examining the potential of modified intravascular ultrasound (IVUS) catheters to facilitate dual diagnostic and therapeutic roles using ultrasound plus microbubbles for localized drug delivery to the vessel wall. The goal of this study was to design, prototype, and validate an IVUS transducer for microbubble-based drug delivery. A 1-D acoustic radiation force model and finite element analysis guided the design of a 1.5-MHz IVUS transducer. Using the IVUS transducer, biotinylated microbubbles were displaced in water and bovine whole blood to the streptavidin-coated wall of a flow phantom by a 1.5-MHz center frequency, peak negative pressure = 70 kPa pulse with varying pulse repetition frequency (PRF) while monitoring microbubble adhesion with ultrasound. A fit was applied to the RF data to extract a time constant (τ). As PRF was increased in water, the time constant decreased (τ = 32.6 s, 1 kHz vs. τ = 8.2 s, 6 kHz), whereas in bovine whole blood an adhesion–no adhesion transition was found for PRFs ≥ 8 kHz. Finally, a fluorophore was delivered to an ex vivo swine artery using microbubbles and the IVUS transducer, resulting in a 6.6-fold increase in fluorescence. These results indicate the importance of PRF (or duty factor) for IVUS acoustic radiation force microbubble displacement and the potential for IVUS and microbubbles to provide localized drug delivery. PMID:24569249

  5. Reliable, self-calibrating vibration transducer

    NASA Technical Reports Server (NTRS)

    Mc Kinney, R. L.

    1968-01-01

    Transducer system measures the uniaxial vibration amplitudes /deflections/ and frequency of a body subjected to mechanical vibration. The basic system is self-calibrating and provides an output which unambiguously indicates the direction as well as the magnitude of the uniaxial deflections.

  6. Attaching strain transducers to fragile materials

    NASA Technical Reports Server (NTRS)

    Duggan, M. F.

    1979-01-01

    A-shaped clamp prevents damage to thin, brittle specimens and supports displacement transducer away from heated zone. Also it defines reference points for strain measurement on specimen surface thus preventing specimen cracking due to unequal thermal expansion between clamp and holder.

  7. Myocardium wall thickness transducer and measuring method

    NASA Technical Reports Server (NTRS)

    Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H. (Inventor)

    1976-01-01

    A miniature transducer for measuring changes of thickness of the myocardium is described. The device is easily implantable without traumatizing the subject, without affecting the normal muscle behavior, and is removable and implantable at a different muscle location. Operating features of the device are described.

  8. Non-bonded piezoelectric ultrasonic transducer

    DOEpatents

    Eoff, James M.

    1985-01-01

    A mechanically assembled non-bonded ultrasonic transducer includes a substrate, a piezoelectric film, a wetting agent, a thin metal electrode, and a lens held in intimate contact by a mechanical clamp. No epoxy or glue is used in the assembly of this device.

  9. Unified Technical Concepts. Module 10: Transducers.

    ERIC Educational Resources Information Center

    Technical Education Research Center, Waco, TX.

    This concept module on transducers is one of thirteen modules that provide a flexible, laboratory-based physics instructional package designed to meet the specialized needs of students in two-year, postsecondary technical schools. Each of the thirteen concept modules discusses a single physics concept and how it is applied to each energy system.…

  10. Improved convergence of electromechanical transducer element

    NASA Astrophysics Data System (ADS)

    Sattler, Robert; Wachutka, Gerhard

    2002-04-01

    Electrostatic attraction is a favored principle of actuation in MEMS (e.g. mirrors, relays, membrane devices). In this work we use an electrostatically actuated membrane as demonstrator. Physically based device models require the coupling of the electrostatic and the two domains. One way to reduce this expense consists in reduced order modeling by introducing a local approximation of the electric field using the Differential-Plate-Capacitor-Approximation (DPCA). This semi-analytical approximation can be directly (matrix coupled transducer element) or sequentially (load vector coupling) coupled with the mechanical solver. Both approaches yield results which agree well with those of coupled 3D-field solvers. It turns out that the transducer element converges much faster than the sequentially coupled relaxation scheme, as ong as the voltage is not close to the pull-in voltage. If this is the case then the transducer element has problems to find the equilibrium state at all. To avoid this difficulty we propose the use of a homotopy method to give the transducer element the same accuracy and robustness in the stable and the unstable regions of the operating area. The electrostatic charge and the electrostatic force turn out to be proper homotopy parameters for the given example.

  11. Composition.

    ERIC Educational Resources Information Center

    Nemanich, Donald, Ed.

    1974-01-01

    The articles in this special issue of the "Illinois English Bulletin" concern the state of composition instruction at the secondary and college levels. The titles and authors are "Monologues or Dialogues? A Plea for Literacy" by Dr. Alfred J. Lindsey, "Teaching Composition: Curiouser and Curiouser" by Denny Brandon, and "Teaching Writing to High…

  12. Evolvable Cryogenics (ECRYO) Pressure Transducer Calibration Test

    NASA Technical Reports Server (NTRS)

    Diaz, Carlos E., Jr.

    2015-01-01

    This paper provides a summary of the findings of recent activities conducted by Marshall Space Flight Center's (MSFC) In-Space Propulsion Branch and MSFC's Metrology and Calibration Lab to assess the performance of current "state of the art" pressure transducers for use in long duration storage and transfer of cryogenic propellants. A brief historical narrative in this paper describes the Evolvable Cryogenics program and the relevance of these activities to the program. This paper also provides a review of three separate test activities performed throughout this effort, including: (1) the calibration of several pressure transducer designs in a liquid nitrogen cryogenic environmental chamber, (2) the calibration of a pressure transducer in a liquid helium Dewar, and (3) the calibration of several pressure transducers at temperatures ranging from 20 to 70 degrees Kelvin (K) using a "cryostat" environmental chamber. These three separate test activities allowed for study of the sensors along a temperature range from 4 to 300 K. The combined data shows that both the slope and intercept of the sensor's calibration curve vary as a function of temperature. This homogeneous function is contrary to the linearly decreasing relationship assumed at the start of this investigation. Consequently, the data demonstrates the need for lookup tables to change the slope and intercept used by any data acquisition system. This ultimately would allow for more accurate pressure measurements at the desired temperature range. This paper concludes with a review of a request for information (RFI) survey conducted amongst different suppliers to determine the availability of current "state of the art" flight-qualified pressure transducers. The survey identifies requirements that are most difficult for the suppliers to meet, most notably the capability to validate the sensor's performance at temperatures below 70 K.

  13. Transducer technology transfer to bio-engineering applications. [aerospace stress transducer for heart function analysis

    NASA Technical Reports Server (NTRS)

    Duran, E. N.; Lewis, G. W.; Feldstein, C.; Corday, E.; Meerbaum, S.; Lang, T.

    1973-01-01

    The results of a technology transfer of a miniature unidirectional stress transducer, developed for experimental stress analysis in the aerospace field, to applications in bioengineering are reported. By modification of the basic design and innovations in attachment techniques, the transducer was successfully used in vivo on the myocardium of large dogs to record the change in contractile force due to coronary occlusion, reperfusion, and intervention.

  14. Mounting technique for pressure transducers minimizes measurement interferences

    NASA Technical Reports Server (NTRS)

    Lanham, R. N.; Taylor, C. E.; Balmer, C. E.; Hwang, C.

    1975-01-01

    Miniaturized transducers are fabricated from commercially available four-arm semiconductor gages; transducers are connected as bridge circuit and mounted on internal face of small diaphragm. Jacket made of conductive plastic may be needed to avoid buildup or static charges.

  15. Pressure transducer system is force-balanced, has digital output

    NASA Technical Reports Server (NTRS)

    1965-01-01

    Forced-balanced pressure transducer and associated circuitry controls pressure testing of space equipment systems under actual operating conditions. The transducer and circuitry automatically converts the sensed pressure to digital form.

  16. New type pressure transducer for severe thermal environments

    NASA Technical Reports Server (NTRS)

    1969-01-01

    Pressure transducer used in a rocket motor chamber to measure the amplitudes and frequencies of dynamic pressures /exceeding 2000 psi/ occurring during unstable combustion. the transducer utilizes a transpirational cooled porous beryllium plug and pressure transmitting column.

  17. Non-Planar Pad-Printed Thick-Film Focused High-Frequency Ultrasonic Transducers for Imaging and Therapeutic Applications

    PubMed Central

    Lethiecq, Marc; Lou-Moeller, Rasmus; Ketterling, Jeffrey A.; Levassort, Franck; Tran-Huu-Hue, Louis Pascal; Filoux, Erwan; Silverman, Ronald H.; Wolny, Wanda W.

    2013-01-01

    Pad-printed thick-film transducers have been shown to be an interesting alternative to lapped bulk piezoceramics, because the film is deposited with the required thickness, size, and geometry, thus avoiding any subsequent machining to achieve geometrical focusing. Their electromechanical properties are close to those of bulk ceramics with similar composition despite having a higher porosity. In this paper, pad-printed high-frequency transducers based on a low-loss piezoceramic composition are designed and fabricated. High-porosity ceramic cylinders with a spherical top surface are used as the backing substrate. The transducers are characterized in view of imaging applications and their imaging capabilities are evaluated with phantoms containing spherical inclusions and in different biological tissues. In addition, the transducers are evaluated for their capability to produce high-acoustic intensities at frequencies around 20 MHz. High-intensity measurements, obtained with a calibrated hydrophone, show that transducer performance is promising for applications that would require the same device to be used for imaging and for therapy. Nevertheless, the transducer design can be improved, and simulation studies are performed to find a better compromise between low-power and high-power performance. The size, geometry, and constitutive materials of optimized configurations are proposed and their feasibility is discussed. PMID:23007770

  18. Length mode piezoelectric ultrasonic transducer for inspection of solid objects

    NASA Technical Reports Server (NTRS)

    Thompson, R. B. (Inventor)

    1978-01-01

    The transducer is constructed from individual transducer elements arranged in an array and configured to exhibit a predominant, longitudinal mode transversely to the array. The elements are interconnected through thin flexible sheets. Each element is individually damped, and the transducer as a whole is electrically damped through resonance with the clamped capacitance and dissipation. Electrical control permits inphase operation of all transducer elements or control with preselected phase differences.

  19. Signal processing schemes for optical voltage transducer

    NASA Astrophysics Data System (ADS)

    Chen, Jinling; Xie, Delin; Chen, Hongbin; Xie, Latang; Song, Jianhe; Luo, Xiaoni

    2006-02-01

    This paper describes an optical voltage transducer(OVT) for a 35kV system based on Pockels effect in a BGO(Bi 4Ge 3O 12) crystal. OVT used to measure the voltage of power are superior to conventional electromagnet-induced voltage transducer in many aspects, thus it has great potential to applications. It has some advantages. These advantages are: 1)Optics provides total galvanic separation between the measuring point at high voltage (HV) potential and the measuring equipment at ground potential. 2)Transmission of measuring signals in optical fibers is immune to induced electromagnetic noise even in EMI-environment of switchyards and other high voltage installations. 3)Optics and especially optical fibers make the insulation costs independent of voltage levels thus giving an economical advantage at voltage levels above 100kV. 4)The use of optics is expected to reduce the weight of the transducers. 5)Optical transducers are expected to have a large bandwidth than conventional transducers. 6)The output-signals from an optical transducer are easily interfaced with computers and electronically operated equipment such as digital relays. New techniques developed in electronics and optical field including fiber optic technology bring new contributions to the measurement of voltage and electric field. A Pockels voltage sensor has been widely introduced to electrical power transmission and distribution systems and some advantage of the optical voltage measuring techniques are reported. In this paper, a brief summary of electro-optic effects and the principle of OVT is proposed. The signal processing schemes of different optical path and features are analyzed. The basic principle of OVT is to modulate the irradiance of the light-directed to OVT by an optical fiber-according to the potential difference between the HV-line and the ground potential. The modulation of the light is accomplished by placing a material-that has an optical property (the birefringence), which is

  20. 21 CFR 868.2885 - Gas flow transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas flow transducer. 868.2885 Section 868.2885...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2885 Gas flow transducer. (a) Identification. A gas flow transducer is a device intended for medical purposes that is used to convert gas...

  1. 21 CFR 868.2885 - Gas flow transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas flow transducer. 868.2885 Section 868.2885...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2885 Gas flow transducer. (a) Identification. A gas flow transducer is a device intended for medical purposes that is used to convert gas...

  2. 21 CFR 868.2885 - Gas flow transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gas flow transducer. 868.2885 Section 868.2885...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2885 Gas flow transducer. (a) Identification. A gas flow transducer is a device intended for medical purposes that is used to convert gas...

  3. 21 CFR 868.2885 - Gas flow transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas flow transducer. 868.2885 Section 868.2885...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2885 Gas flow transducer. (a) Identification. A gas flow transducer is a device intended for medical purposes that is used to convert gas...

  4. 21 CFR 868.2885 - Gas flow transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gas flow transducer. 868.2885 Section 868.2885 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2885 Gas flow transducer. (a) Identification. A gas flow transducer is a device intended...

  5. 21 CFR 868.2900 - Gas pressure transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Gas pressure transducer. 868.2900 Section 868.2900...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2900 Gas pressure transducer. (a) Identification. A gas pressure transducer is a device intended for medical purposes that is used to convert...

  6. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment...

  7. 21 CFR 868.2875 - Differential pressure transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Differential pressure transducer. 868.2875 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2875 Differential pressure transducer. (a) Identification. A differential pressure transducer is a two-chambered device intended...

  8. 21 CFR 868.2900 - Gas pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Gas pressure transducer. 868.2900 Section 868.2900...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2900 Gas pressure transducer. (a) Identification. A gas pressure transducer is a device intended for medical purposes that is used to convert...

  9. 21 CFR 868.2900 - Gas pressure transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Gas pressure transducer. 868.2900 Section 868.2900...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2900 Gas pressure transducer. (a) Identification. A gas pressure transducer is a device intended for medical purposes that is used to convert...

  10. 21 CFR 868.2875 - Differential pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Differential pressure transducer. 868.2875 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2875 Differential pressure transducer. (a) Identification. A differential pressure transducer is a two-chambered device intended...

  11. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment...

  12. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment...

  13. 21 CFR 868.2900 - Gas pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Gas pressure transducer. 868.2900 Section 868.2900...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2900 Gas pressure transducer. (a) Identification. A gas pressure transducer is a device intended for medical purposes that is used to convert...

  14. 21 CFR 868.2875 - Differential pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Differential pressure transducer. 868.2875 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2875 Differential pressure transducer. (a) Identification. A differential pressure transducer is a two-chambered device intended...

  15. 21 CFR 870.2060 - Transducer signal amplifier and conditioner.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Transducer signal amplifier and conditioner. 870.2060 Section 870.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Transducer signal amplifier and conditioner. (a) Identification. A transducer signal amplifier...

  16. 21 CFR 870.2060 - Transducer signal amplifier and conditioner.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Transducer signal amplifier and conditioner. 870.2060 Section 870.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Transducer signal amplifier and conditioner. (a) Identification. A transducer signal amplifier...

  17. 21 CFR 870.2060 - Transducer signal amplifier and conditioner.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Transducer signal amplifier and conditioner. 870.2060 Section 870.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Transducer signal amplifier and conditioner. (a) Identification. A transducer signal amplifier...

  18. 21 CFR 870.2060 - Transducer signal amplifier and conditioner.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Transducer signal amplifier and conditioner. 870.2060 Section 870.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Transducer signal amplifier and conditioner. (a) Identification. A transducer signal amplifier...

  19. 21 CFR 870.2060 - Transducer signal amplifier and conditioner.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Transducer signal amplifier and conditioner. 870.2060 Section 870.2060 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... Transducer signal amplifier and conditioner. (a) Identification. A transducer signal amplifier...

  20. 21 CFR 870.2850 - Extravascular blood pressure transducer.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Extravascular blood pressure transducer. 870.2850... blood pressure transducer. (a) Identification. An extravascular blood pressure transducer is a device used to measure blood pressure by changes in the mechanical or electrical properties of the device....

  1. 21 CFR 870.2850 - Extravascular blood pressure transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Extravascular blood pressure transducer. 870.2850... blood pressure transducer. (a) Identification. An extravascular blood pressure transducer is a device used to measure blood pressure by changes in the mechanical or electrical properties of the device....

  2. 21 CFR 870.2850 - Extravascular blood pressure transducer.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Extravascular blood pressure transducer. 870.2850... blood pressure transducer. (a) Identification. An extravascular blood pressure transducer is a device used to measure blood pressure by changes in the mechanical or electrical properties of the device....

  3. 21 CFR 870.2850 - Extravascular blood pressure transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Extravascular blood pressure transducer. 870.2850... blood pressure transducer. (a) Identification. An extravascular blood pressure transducer is a device used to measure blood pressure by changes in the mechanical or electrical properties of the device....

  4. 21 CFR 870.2850 - Extravascular blood pressure transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Extravascular blood pressure transducer. 870.2850... blood pressure transducer. (a) Identification. An extravascular blood pressure transducer is a device used to measure blood pressure by changes in the mechanical or electrical properties of the device....

  5. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... change in relation to changes in blood pressure. These changes are transmitted to accessory equipment for... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip pressure transducer. 870.2870 Section... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated...

  6. 21 CFR 884.2960 - Obstetric ultrasonic transducer and accessories.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Obstetric ultrasonic transducer and accessories... Monitoring Devices § 884.2960 Obstetric ultrasonic transducer and accessories. (a) Identification. An obstetric ultrasonic transducer is a device used to apply ultrasonic energy to, and to receive...

  7. 21 CFR 884.2960 - Obstetric ultrasonic transducer and accessories.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Obstetric ultrasonic transducer and accessories... Monitoring Devices § 884.2960 Obstetric ultrasonic transducer and accessories. (a) Identification. An obstetric ultrasonic transducer is a device used to apply ultrasonic energy to, and to receive...

  8. 21 CFR 884.2960 - Obstetric ultrasonic transducer and accessories.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Obstetric ultrasonic transducer and accessories... Monitoring Devices § 884.2960 Obstetric ultrasonic transducer and accessories. (a) Identification. An obstetric ultrasonic transducer is a device used to apply ultrasonic energy to, and to receive...

  9. 21 CFR 884.2960 - Obstetric ultrasonic transducer and accessories.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Obstetric ultrasonic transducer and accessories... Monitoring Devices § 884.2960 Obstetric ultrasonic transducer and accessories. (a) Identification. An obstetric ultrasonic transducer is a device used to apply ultrasonic energy to, and to receive...

  10. 21 CFR 884.2960 - Obstetric ultrasonic transducer and accessories.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Obstetric ultrasonic transducer and accessories... Monitoring Devices § 884.2960 Obstetric ultrasonic transducer and accessories. (a) Identification. An obstetric ultrasonic transducer is a device used to apply ultrasonic energy to, and to receive...

  11. 21 CFR 892.1570 - Diagnostic ultrasonic transducer.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Diagnostic ultrasonic transducer. 892.1570 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1570 Diagnostic ultrasonic transducer. (a) Identification. A diagnostic ultrasonic transducer is a device made of a piezoelectric...

  12. Adhesion promoters for large scale fabrication of dielectric elastomer stack transducers (DESTs) made of pre-fabricated dielectric films

    NASA Astrophysics Data System (ADS)

    Grotepaß, T.; Förster-Zügel, F.; Mößinger, H.; Schlaak, H. F.

    2015-04-01

    Multilayer dielectric elastomer stack transducers (DESTs) are a promising new transducer technology with many applications in different industry sectors, like medical devices, human-machine-interaction, etc. Stacked dielectric elastomer transducers show larger thickness contraction driven by lower voltages than transducers made from a single dielectric layer. Traditionally multilayered DESTs are produced by repeatedly cross-linking a liquid elastomeric pre-polymer into the required shape. Our recent research focusses on a novel fabrication method for large scale stack transducers with a surface area over 200 x 300 mm by processing pre-fabricated elastomeric thin films of less than 50 μm thicknesses. The thin films are provided as two- or three-layer composites, where the elastomer is sandwiched between one or two sacrificial liners. Separating the elastomeric film from the residual layers and assembling them into dielectric elastomer stack transducers poses many challenges concerning adhesion, since the dielectric film merely separates from the liner if the adhesive forces between them are overcome. Conversely, during the assembly of a dielectric elastomer stack transducer, adhesive forces have to be established between two elastomeric layers or between the dielectric and the electrode layer. The very low Young's modulus of at least one adhesion partner requires suitable means of increasing the adhesive forces between the different adhesive layers of a dielectric elastomer stack transducer to prevent a delamination of the transducer during its lifetime. This work evaluates different surface activation treatments - corona, low-pressure plasma and UV-light - and their applicability in the production of large scale DESTs made from pre-fabricated elastomeric films.

  13. Fabrication and evaluation of a single-element Bi0.5Na0.5TiO3-based ultrasonic transducer.

    PubMed

    Hejazi, M Mehdi; Jadidian, Bahram; Safari, Ahmad

    2012-08-01

    This paper discusses the fabrication and characterization of a single-element ultrasonic transducer with a lead-free piezoelectric active element. A piezoelectric ceramic with composition of 0.88Bi(0.5)Na(0.5)TiO(3)-0.08Bi(0.5)K(0.5)TiO(3)- 0.04Bi(0.5)Li(0.5)TiO(3) was chosen as the active element of the transducer. This composition exhibited a thickness coupling coefficient (kt) of 0.45, a dielectric constant of 440 (at 1 kHz), and a longitudinal piezoelectric coefficient (d(33)) of 84 pC·N(-1). To make the transducer, the ceramic was sandwiched between an epoxy-tungsten backing layer and a silver epoxy matching layer. An epoxy lens was also incorporated into the transducer's design to focus the ultrasound beam. The focused transducer with a center frequency of about 23 MHz demonstrated a -6-dB bandwidth of 55% and an insertion loss of -32 dB; the -20-dB pulsed length was measured to be 150 ns. A phantom made of copper wires (30 μm in diameter) was utilized to investigate the imaging capability of the transducer. The results indicated that the fabricated transducer, with a lateral resolution of 260 μm and a relatively high depolarization temperature, could be considered as a candidate for replacement of lead-based ultrasonic transducers. PMID:22899131

  14. Nonlinear dielectric response in piezoelectric materials for underwater transducers

    NASA Astrophysics Data System (ADS)

    Sherlock, N. P.; Garten, L. M.; Zhang, S. J.; Shrout, T. R.; Meyer, R. J.

    2012-12-01

    SONAR transducers based on single crystal lead magnesium niobate-lead titanate (PMNT) have demonstrated improvements over conventional lead zirconate titanate ceramics. Compositional modifications to PMNT have combined the high piezoelectric coefficient (d33 > 2000 pC/N) and electromechanical coupling factor (k33 > 0.90) with the low mechanical losses (QM > 1000) of "hard" piezoelectric ceramics. The dielectric losses of single crystal PMNT have not been investigated as extensively as the mechanical losses but may significantly affect the performance of a device when water loaded. In this work, nonlinearities in the dielectric permittivity and losses have been investigated as a function of applied electric field, measurement frequency, and temperature. It is shown that electromechanically "hard" single crystals offer greater stability of the dielectric properties while maintaining a high permittivity with respect to conventional lead zirconate titanate ceramics.

  15. 16 CFR 1.3 - Advice.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 16 Commercial Practices 1 2012-01-01 2012-01-01 false Advice. 1.3 Section 1.3 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.3 Advice. (a) On the basis of the materials submitted, as well as any...

  16. 43 CFR 3452.1-3 - Acceptance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Acceptance. 3452.1-3 Section 3452.1-3 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT..., Cancellation, and Termination § 3452.1-3 Acceptance. The effective date of the lease relinquishment shall,...

  17. 50 CFR 1.3 - Service.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Service. 1.3 Section 1.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS DEFINITIONS § 1.3 Service. Service means the United States Fish and Wildlife Service, Department of the Interior....

  18. 27 CFR 1.3 - Forms prescribed.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Forms prescribed. 1.3 Section 1.3 Alcohol, Tobacco Products and Firearms ALCOHOL AND TOBACCO TAX AND TRADE BUREAU, DEPARTMENT OF..., NONINDUSTRIAL USE OF DISTILLED SPIRITS AND WINE, BULK SALES AND BOTTLING OF DISTILLED SPIRITS Scope § 1.3...

  19. 21 CFR 1.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 1 2010-04-01 2010-04-01 false Definitions. 1.3 Section 1.3 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES GENERAL GENERAL ENFORCEMENT REGULATIONS General Provisions § 1.3 Definitions. (a) Labeling includes all written, printed, or...

  20. 5 CFR 1.3 - Definitions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 5 Administrative Personnel 1 2014-01-01 2014-01-01 false Definitions. 1.3 Section 1.3 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE RULES COVERAGE AND DEFINITIONS (RULE I) § 1.3 Definitions. As used in the rules in this subchapter: (a) Competitive service shall have the...

  1. 50 CFR 1.3 - Service.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 1 2011-10-01 2011-10-01 false Service. 1.3 Section 1.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS DEFINITIONS § 1.3 Service. Service means the United States Fish and Wildlife Service, Department of the Interior....

  2. 50 CFR 1.3 - Service.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 1 2012-10-01 2012-10-01 false Service. 1.3 Section 1.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS DEFINITIONS § 1.3 Service. Service means the United States Fish and Wildlife Service, Department of the Interior....

  3. 50 CFR 1.3 - Service.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 1 2013-10-01 2013-10-01 false Service. 1.3 Section 1.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS DEFINITIONS § 1.3 Service. Service means the United States Fish and Wildlife Service, Department of the Interior....

  4. 50 CFR 1.3 - Service.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 1 2014-10-01 2014-10-01 false Service. 1.3 Section 1.3 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS DEFINITIONS § 1.3 Service. Service means the United States Fish and Wildlife Service, Department of the Interior....

  5. 17 CFR 1.3 - Definitions.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 17 Commodity and Securities Exchanges 1 2012-04-01 2012-04-01 false Definitions. 1.3 Section 1.3 Commodity and Securities Exchanges COMMODITY FUTURES TRADING COMMISSION GENERAL REGULATIONS UNDER THE COMMODITY EXCHANGE ACT Definitions § 1.3 Definitions. Words used in the singular form in the rules and regulations in this chapter shall be deemed...

  6. 43 CFR 8365.1-3 - Vehicles.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 43 Public Lands: Interior 2 2011-10-01 2011-10-01 false Vehicles. 8365.1-3 Section 8365.1-3 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR RECREATION PROGRAMS VISITOR SERVICES Rules of Conduct § 8365.1-3 Vehicles. (a)...

  7. 43 CFR 8365.1-3 - Vehicles.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 43 Public Lands: Interior 2 2013-10-01 2013-10-01 false Vehicles. 8365.1-3 Section 8365.1-3 Public Lands: Interior Regulations Relating to Public Lands (Continued) BUREAU OF LAND MANAGEMENT, DEPARTMENT OF THE INTERIOR RECREATION PROGRAMS VISITOR SERVICES Rules of Conduct § 8365.1-3 Vehicles. (a)...

  8. 45 CFR 1210.1-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Definitions. 1210.1-3 Section 1210.1-3 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE VISTA TRAINEE DESELECTION AND VOLUNTEER EARLY TERMINATION PROCEDURES General § 1210.1-3 Definitions. (a) Trainee means a person enrolled in...

  9. 45 CFR 1211.1-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Definitions. 1211.1-3 Section 1211.1-3 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE VOLUNTEER GRIEVANCE PROCEDURES § 1211.1-3 Definitions. (a) Volunteer means a person enrolled and currently serving as a full-time volunteer...

  10. 45 CFR 1216.1-3 - Policy.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Policy. 1216.1-3 Section 1216.1-3 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE NONDISPLACEMENT OF EMPLOYED WORKERS AND NONIMPAIRMENT OF CONTRACTS FOR SERVICE § 1216.1-3 Policy. (a) Volunteers enrolled or participating in...

  11. 5 CFR 1.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 5 Administrative Personnel 1 2010-01-01 2010-01-01 false Definitions. 1.3 Section 1.3 Administrative Personnel OFFICE OF PERSONNEL MANAGEMENT CIVIL SERVICE RULES COVERAGE AND DEFINITIONS (RULE I) § 1.3 Definitions. As used in the rules in this subchapter: (a) Competitive service shall have the...

  12. 16 CFR 1.3 - Advice.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 16 Commercial Practices 1 2010-01-01 2010-01-01 false Advice. 1.3 Section 1.3 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.3 Advice. (a) On the basis of the materials submitted, as well as any...

  13. 16 CFR 1.3 - Advice.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 16 Commercial Practices 1 2011-01-01 2011-01-01 false Advice. 1.3 Section 1.3 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.3 Advice. (a) On the basis of the materials submitted, as well as any...

  14. 16 CFR 1.3 - Advice.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 16 Commercial Practices 1 2013-01-01 2013-01-01 false Advice. 1.3 Section 1.3 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.3 Advice. (a) On the basis of the materials submitted, as well as any...

  15. 16 CFR 1.3 - Advice.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 16 Commercial Practices 1 2014-01-01 2014-01-01 false Advice. 1.3 Section 1.3 Commercial Practices FEDERAL TRADE COMMISSION ORGANIZATION, PROCEDURES AND RULES OF PRACTICE GENERAL PROCEDURES Industry Guidance Advisory Opinions § 1.3 Advice. (a) On the basis of the materials submitted, as well as any...

  16. Thermal-Independent Properties of PIN-PMN-PT Single-Crystal Linear-Array Ultrasonic Transducers

    PubMed Central

    Chen, Ruimin; Wu, Jinchuan; Lam, Kwok Ho; Yao, Liheng; Zhou, Qifa; Tian, Jian; Han, Pengdi; Shung, K. Kirk

    2013-01-01

    In this paper, low-frequency 32-element linear-array ultrasonic transducers were designed and fabricated using both ternary Pb(In1/2Nb1/2)–Pb(Mg1/3Nb2/3)–PbTiO3 (PIN-PMN-PT) and binary Pb(Mg1/3Nb2/3)–PbTiO3 (PMN-PT) single crystals. Performance of the array transducers was characterized as a function of temperature ranging from room temperature to 160°C. It was found that the array transducers fabricated using the PIN-PMN-PT single crystal were capable of satisfactory performance at 160°C, having a −6-dB bandwidth of 66% and an insertion loss of 37 dB. The results suggest that the potential of PIN-PMN-PT linear-array ultrasonic transducers for high-temperature ultrasonic transducer applications is promising. PMID:23221227

  17. Electromechanical transducer for acoustic telemetry system

    DOEpatents

    Drumheller, Douglas S.

    1993-01-01

    An improved electromechanical transducer is provided for use in an acoustic telemetry system. The transducer of this invention comprises a stack of ferroelectric ceramic disks interleaved with a plurality of spaced electrodes which are used to electrically pole the ceramic disks. The ceramic stack is housed in a metal tubular drill collar segment. The electrodes are preferably alternatively connected to ground potential and driving potential. This alternating connection of electrodes to ground and driving potential subjects each disk to an equal electric field; and the direction of the field alternates to match the alternating direction of polarization of the ceramic disks. Preferably, a thin metal foil is sandwiched between electrodes to facilitate the electrical connection. Alternatively, a thicker metal spacer plate is selectively used in place of the metal foil in order to promote thermal cooling of the ceramic stack.

  18. Bonded ultrasonic transducer and method for making

    DOEpatents

    Dixon, R.D.; Roe, L.H.; Migliori, A.

    1995-11-14

    An ultrasonic transducer is formed as a diffusion bonded assembly of piezoelectric crystal, backing material, and, optionally, a ceramic wear surface. The mating surfaces of each component are silver films that are diffusion bonded together under the application of pressure and heat. Each mating surface may also be coated with a reactive metal, such as hafnium, to increase the adhesion of the silver films to the component surfaces. Only thin silver films are deposited, e.g., a thickness of about 0.00635 mm, to form a substantially non-compliant bond between surfaces. The resulting transducer assembly is substantially free of self-resonances over normal operating ranges for taking resonant ultrasound measurements. 12 figs.

  19. Bonded ultrasonic transducer and method for making

    DOEpatents

    Dixon, Raymond D.; Roe, Lawrence H.; Migliori, Albert

    1995-01-01

    An ultrasonic transducer is formed as a diffusion bonded assembly of piezoelectric crystal, backing material, and, optionally, a ceramic wear surface. The mating surfaces of each component are silver films that are diffusion bonded together under the application of pressure and heat. Each mating surface may also be coated with a reactive metal, such as hafnium, to increase the adhesion of the silver films to the component surfaces. Only thin silver films are deposited, e.g., a thickness of about 0.00635 mm, to form a substantially non-compliant bond between surfaces. The resulting transducer assembly is substantially free of self-resonances over normal operating ranges for taking resonant ultrasound measurements.

  20. Acoustic transducer apparatus with reduced thermal conduction

    NASA Technical Reports Server (NTRS)

    Lierke, Ernst G. (Inventor); Leung, Emily W. (Inventor); Bhat, Balakrishna T. (Inventor)

    1990-01-01

    A horn is described for transmitting sound from a transducer to a heated chamber containing an object which is levitated by acoustic energy while it is heated to a molten state, which minimizes heat transfer to thereby minimize heating of the transducer, minimize temperature variation in the chamber, and minimize loss of heat from the chamber. The forward portion of the horn, which is the portion closest to the chamber, has holes that reduce its cross-sectional area to minimize the conduction of heat along the length of the horn, with the entire front portion of the horn being rigid and having an even front face to efficiently transfer high frequency acoustic energy to fluid in the chamber. In one arrangement, the horn has numerous rows of holes extending perpendicular to the length of horn, with alternate rows extending perpendicular to one another to form a sinuous path for the conduction of heat along the length of the horn.

  1. Electromechanical transducer for acoustic telemetry system

    DOEpatents

    Drumheller, D.S.

    1993-06-22

    An improved electromechanical transducer is provided for use in an acoustic telemetry system. The transducer of this invention comprises a stack of ferroelectric ceramic disks interleaved with a plurality of spaced electrodes which are used to electrically pole the ceramic disks. The ceramic stack is housed in a metal tubular drill collar segment. The electrodes are preferably alternatively connected to ground potential and driving potential. This alternating connection of electrodes to ground and driving potential subjects each disk to an equal electric field; and the direction of the field alternates to match the alternating direction of polarization of the ceramic disks. Preferably, a thin metal foil is sandwiched between electrodes to facilitate the electrical connection. Alternatively, a thicker metal spacer plate is selectively used in place of the metal foil in order to promote thermal cooling of the ceramic stack.

  2. Gel-Filled Holders For Ultrasonic Transducers

    NASA Technical Reports Server (NTRS)

    Companion, John A.

    1992-01-01

    In new technique, ultrasonic transducer embedded in rubbery, castable, low-loss gel to enable transducer to "look" into surface of test object or human body at any desired angle. Composed of solution of water and ethylene glycol in collagen matrix. Provides total contact of water bath, also used on bodies or objects too large for water baths, even if moving. Also provides look angles of poly(methyl methacrylate) angle block with potential of reduced acoustic impedance and refraction. Custom-tailored to task at hand, and gel sufficiently inexpensive to be discarded upon completion. Easy to couple ultrasound in and out of gel, minimizing losses and artifacts of other types of standoffs employed in ultrasonic testing.

  3. Reliability of high strain ionomeric polymer transducers fabricated using the direct assembly process

    NASA Astrophysics Data System (ADS)

    Akle, Barbar; Nawshin, Saila; Leo, Donald

    2007-04-01

    Ionomeric polymer transducers have received considerable attention in the past several years. These actuators, sometimes referred to as artificial muscles, have the ability to generate large bending strain and moderate stress at low applied voltages. As sensors, ionic polymer transducers generate an electric response due to mechanical strain. Typically, ionic polymer transducers are composed of Nafion-117 membranes with platinum electrodes and are saturated with water diluents. Recently the authors have developed a novel fabrication technique called the direct assembly process (DAP), which allowed improved control of the electrode morphology and composition. The DAP consists of spraying two high surface area metal-ionomer electrodes on a Nafion membrane. The benefits of the DAP process over previous methods is the ability to control the thickness of the electrode, the ability to control the composition of the electrode layer of the transducer, and the ability for it to be used with a wide variety of diluents. In past work we have demonstrated that platinum, ruthenium dioxide, and single-walled carbon nanotubes can be used as electrode material with diluents such as water, formamide, and ionic liquids. In this work we will present a reliability study of transducers fabricated using the DAP. Water-hydrated transducers dehydrate and stop moving within 5 min while operating in air under the application of ± 2 V. Ionic liquid based transducers are demonstrated to operate in air for over 400 000 cycles with little loss in performance, and are reliable up to 1 million cycles with a performance loss of less than 43%. The main source of degradation is the adhesion of the conductive surface to the high surface area electrode. This is enhanced in this study by using a PUU linking polymer that has good adhesion properties to gold. Large voltage and large strain are proven to decrease the life of the transducer. Formamide based samples are stable for 3 days under a 1 V

  4. Flutter spectral measurements using stationary pressure transducers

    NASA Technical Reports Server (NTRS)

    Kurkov, A. P.

    1980-01-01

    Engine-order sampling was used to eliminate the integral harmonics from the flutter spectra corresponding to a case-mounted static pressure transducer. Using the optical displacement data, it was demonstrated that the blade-order sampling of pressure data may yield erroneous results due to the interference caused by blade vibration. Two methods are presented which effectively eliminate this interference yielding the blade-pressure-difference spectra. The phase difference between the differential-pressure and the displacement spectra was evaluated.

  5. Robust Acoustic Transducers for Bubble Chambers

    NASA Astrophysics Data System (ADS)

    Wells, Jonathan

    2015-04-01

    The PICO collaboration utilizes bubble chambers filled with various superheated liquids as targets for dark matter. Acoustic sensors have proved able to distinguish nuclear recoils from radioactive background on an event-by-event basis. We have recently produced a more robust transducer which should be able to operate for years, rather than months, in the challenging environment of a heated high pressure hydraulic fluid outside these chambers. Indiana University South Bend.

  6. Ultrasonic transducer with Gaussian radial pressure distribution

    NASA Technical Reports Server (NTRS)

    Claus, R. O.; Zerwekh, P. S. (Inventor)

    1984-01-01

    An ultrasonic transducer that produces an output that is a symmetrical function comprises a piezoelectric crystal with several concentric ring electrodes on one side of the crystal. A resistor network applies different amplitudes of an ac source to each of the several electrodes. A plot of the different amplitudes from the outermost electrode to the innermost electrode is the first half of a Gaussian function. Consequently, the output of the crystal from the side opposite the electrodes has a Gaussian profile.

  7. Modeling a magnetostrictive transducer using genetic algorithm

    NASA Astrophysics Data System (ADS)

    Almeida, L. A. L.; Deep, G. S.; Lima, A. M. N.; Neff, H.

    2001-05-01

    This work reports on the applicability of the genetic algorithm (GA) to the problem of parameter determination of magnetostrictive transducers. A combination of the Jiles-Atherton hysteresis model with a quadratic moment rotation model is simulated using known parameters of a sensor. The simulated sensor data are then used as input data for the GA parameter calculation method. Taking the previously known parameters, the accuracy of the GA parameter calculation method can be evaluated.

  8. Characterization of transducer cavities to oscillatory inputs

    SciTech Connect

    Rogers, J.D.; Hollingshead, J.R.

    1993-12-31

    The design and use of measurement systems must ensure that the data are not computed by the measurement system. A wide variety of sources can be responsible for compromising the integrity of test data. Among the sources of error are transducer calibration errors, signal conditioning problems, recording problems, and characteristics of the mechanical system which introduce errors. In this paper, the characteristics of an acoustic cavity are discussed as they apply to a pressure measurement problem.

  9. Composites

    SciTech Connect

    Chou, T.; McCullough, R.L.; Pipes, R.B.

    1986-10-01

    The degree of control over material properties that is typified by hybrid composites is transforming engineering design. In part because homogeneous materials such as metals and alloys do not offer comparable control, specifying a material and designing a component have traditionally taken place separately. As composites begin to replace traditional materials in fields and such as aerospace, component design and the specification of a material are merging and becoming aspects of a single process. The controllable microstructure of a composite allows it to be tailored to match the distribution of stresses to which it will be subject. At the same time components must come to reflect the distinctive nature of composites: their directional properties and the intricate forms they can be given through processes such as injection molding, filament winding and three-dimensional weaving. The complexity inherent in conceiving components and their materials at the same time suggests engineering design will grow increasingly dependent on computers and multidisciplinary teams. Such an approach will harness the full potential of composites for the technologies of the future. 10 figures.

  10. "Zero-Mass" Noninvasive Pressure Transducers

    NASA Technical Reports Server (NTRS)

    Hartley, Frank T.

    2009-01-01

    Extremely lightweight, compact, noninvasive, rugged, relatively inexpensive strain-gauge transducers have been developed for use in measuring pressures of fluids in tubes. These gauges were originally intended for measuring pressures of spacecraft-propulsion fluids, but they are also attractive for use in numerous terrestrial applications especially those involving fluids that are extremely chemically reactive, fluids that must be isolated for hygienic purposes, fluids that must be allowed to flow without obstruction, and fluid-containing tubes exposed to severe environments. A basic pressure transducer of this type comprises one or more pair(s) of thin-film strain gauges integral with a tube that contains the fluid of interest. Following established strain-gauge practice, the gauges in each pair are connected into opposite arms of a Wheatstone bridge (see figure). Typically, each pressure transducer includes one pair (the active pair) of strain gauges for measuring the hoop stress proportional to the pressure of the fluid in the tube and another pair (the dummy pair) of strain gauges that are nominally unstrained: The dummy gauges are mounted on a substrate that is made of the same material as that of the tube. The substrate is welded to the tube at only one spot so that stresses and strains are not coupled from the tube into the substrate. The dummy strain gauges measure neutral strains (basically, strains associated with thermal expansion), so that the neutral-strain contribution can be subtracted out of the final gauge reading.

  11. Marine transducing bacteriophage attacking a luminous bacterium.

    PubMed

    Keynan, A; Nealson, K; Sideropoulos, H; Hastings, J W

    1974-08-01

    The isolation and partial characterization of a marine bacteriophage attacking a strain of luminous bacteria is described, including some physical, biological, and genetic properties. It is a DNA phage of density of 1.52 with a long flexible tail and an apparently icosohedral head. With respect to stability in suspension, it has a rather specific requirement for the sodium ion in high concentration; it is further stabilized by the addition of calcium and magnesium ions. These same ions are likewise all required for both good plating efficiency and plaque uniformity. Although it goes through a typical lytic growth cycle (about 45 min), with a burst size of 100, and no stable lysogens have been isolated, it is nevertheless a transducing phage specifically for the tryptophan region, transducing several, but not all, independently isolated Trp(-) auxotrophs to protrophy. No other auxotrophs of a variety of amino acids were transduced by this phage to prototrophy. Phage infection does not change the normal expression of the luminescent system, and light remains at near normal levels until cell lysis occurs. PMID:16789143

  12. Simultaneous muscle force and displacement transducer

    NASA Technical Reports Server (NTRS)

    Feldstein, C.; Lewis, G. W.; Culler, V. H. (Inventor)

    1980-01-01

    A myocardial transducer for simultaneously measuring force and displacement within a very small area of myocardium is disclosed. The transducer comprised of an elongated body forked at one end to form an inverted Y shaped beam with each branch of the beam constituting a low compliant tine for penetrating the myocardium to a predetermined depth. Bonded to one of the low compliance tines is a small piezoresistive element for converting a force acting on the beam into an electrical signal. A third high compliant tine of the transducer, which measures displacement of the myocardium in a direction in line with the two low compliant tines, is of a length that just pierces the surface membrane. A small piezoresistive element is bonded to the third tine at its upper end where its bending is greatest. Displacement of the myocardium causes a deformation in curvature of the third tine, and the second small piezoresistive element bonded to the surface of its curved end converts its deformation into an electrical signal.

  13. Sector array transducers for vibro-acoustography

    NASA Astrophysics Data System (ADS)

    Silva, Glauber; Chen, Shigao; Kinnick, Randall; Greenleaf, James; Fatemi, Mostafa

    2003-10-01

    Vibro-acoustography is an imaging technique that maps the acoustic response of an object to a localized harmonic radiation force. This force is generated by two interfering continuous-wave ultrasound beams at slightly different frequencies f1 and f2. The system point-spread function (PSF) is related to the radiation force on a point-target. Imaging artifacts depend on the PSF sidelobes, which can be reduced by mismatching the sidelobes of each ultrasound beam. Here, we propose a beamforming approach based on an 8-element sector transducer with consecutive elements alternately driven at f1 and f2. The transducer generates two ultrasound beams skewed by 22.5° with respect to each other. The system PSF is analytically derived. The theory is validated by experiments using a small steel sphere (radius =0.2 mm) as a point-target. A laser vibrometer is used to measure the vibration of the sphere and evaluate the PSF of the system. Theoretically, the PSF sidelobes are under -15.8 dB in eight spots circularly distributed and separated by 22.5°, which agrees with the experimental results. Simulation shows that with 16 elements sidelobes are under -35.2 dB. In conclusion, sector transducers for vibro-acoustography may have lower sidelobes as the number of array elements is increased. [Work supported by Grant Nos. EB00535-01, EB2640, and IMG0100744.

  14. Cross-fiber Bragg grating transducer

    NASA Technical Reports Server (NTRS)

    Albin, Sacharia (Inventor); Zheng, Jianli (Inventor); Lavarias, Arnel (Inventor)

    2000-01-01

    A transducer has been invented that uses specially-oriented gratings in waveguide a manner that allows the simultaneous measurement of physical phenomena (such as shear force, strain and temperature) in a single sensing element. The invention has a highly sensitive, linear response and also has directional sensitivity with regard to strain. The transducer has a waveguide with a longitudinal axis as well as two Bragg gratings. The transducer has a first Bragg grating associated with the waveguide that has an angular orientation .theta..sub.a relative to a perpendicular to the longitudinal axis such that 0.degree.<.theta..sub.a <.theta..sub.max. The second Bragg grating is associated with the waveguide in such a way that the angular orientation .theta..sub.b of the grating relative to a perpendicular to the longitudinal axis is (360.degree.-.theta..sub.max)<.theta..sub.b <360.degree.. The first Bragg grating can have a periodicity .LAMBDA..sub.a and the second Bragg grating can have a periodicity .LAMBDA..sub.b such that the periodicity .LAMBDA..sub.a of the first Bragg grating does not equal the periodicity .LAMBDA..sub.b of the second Bragg grating. The angle of the gratings can be such that .theta..sub.a =360.degree.-.theta..sub.b. The waveguide can assume a variety of configurations, including an optical fiber, a rectangular waveguide and a planar waveguide. The waveguide can be fabricated of a variety of materials, including silica and polymer material.

  15. Language of Transducer Manipulation: Codifying Terms for Effective Teaching.

    PubMed

    Bahner, David P; Blickendorf, J Matthew; Bockbrader, Marcia; Adkins, Eric; Vira, Amar; Boulger, Creagh; Panchal, Ashish R

    2016-01-01

    There is a need for consistent, repetitive, and reliable terminology to describe the basic manipulations of the ultrasound transducer. Previously, 5 basic transducer motions have been defined and used in education. However, even with this effort, there is still a lack of consistency and clarity in describing transducer manipulation and motion. In this technical innovation, we describe an expanded definition of transducer motions, which include movements to change the transducer's angle of insonation to the target as well as the location on the body to optimize the ultrasound image. This new terminology may allow for consistent teaching and improved communication in the process of image acquisition. PMID:26679204

  16. New Methods and Transducer Designs for Ultrasonic Diagnostics and Therapy

    NASA Astrophysics Data System (ADS)

    Rybyanets, A. N.; Naumenko, A. A.; Sapozhnikov, O. A.; Khokhlova, V. A.

    Recent advances in the field of physical acoustics, imaging technologies, piezoelectric materials, and ultrasonic transducer design have led to emerging of novel methods and apparatus for ultrasonic diagnostics, therapy and body aesthetics. The paper presents the results on development and experimental study of different high intensity focused ultrasound (HIFU) transducers. Technological peculiarities of the HIFU transducer design as well as theoretical and numerical models of such transducers and the corresponding HIFU fields are discussed. Several HIFU transducers of different design have been fabricated using different advanced piezoelectric materials. Acoustic field measurements for those transducers have been performed using a calibrated fiber optic hydrophone and an ultrasonic measurement system (UMS). The results of ex vivo experiments with different tissues as well as in vivo experiments with blood vessels are presented that prove the efficacy, safety and selectivity of the developed HIFU transducers and methods.

  17. Environmental control system transducer development study. [for space shuttles

    NASA Technical Reports Server (NTRS)

    Brudnicki, M. J.

    1974-01-01

    A development test program of transducers for aerospace projects is described. Stability and performance of existing transducers, and improvements compatible with shuttle ECS requirements are investigated. These requirements incorporate design and development features into the transducers, and include the following: (1) improvement of overall transducer ruggedness and reliability; (2) common transducers for all ECS fluids that will be unaffected by long quiescent periods in the space environment, that will require no maintenance or refurbishing for at least 100 launches; and (3) appropriate self-check features that simplify checkout and maintenance. Models of three different transducers, a three-way valve for pressure transducers from closed liquid loops, surface-type platinum-wire resistance temperature sensors, and a nuclenics gaging system are evaluated. Tests and development improvements are described.

  18. Giant magnetoelectric effect (under a dc magnetic bias of 2 Oe) in laminate composites of FeBSiC alloy ribbons and Pb(Zn{sub 1/3},Nb{sub 2/3})O{sub 3}-7%PbTiO{sub 3} fibers

    SciTech Connect

    Dong Shuxiang; Zhai Junyi; Xing Zhengping; Li Jiefang; Viehland, D.

    2007-07-09

    Giant magnetoelectric (ME) voltage and charge coefficients have been found in long-type composites of high-permeability magnetostrictive FeBSiC alloy ribbons laminated together with piezoelectric Pb(Zn{sub 1/3},Nb{sub 2/3})O{sub 3}-7%PbTiO{sub 3} single crystal fibers. The maximum ME voltage and charge coefficients at low frequencies were 10.5 V/cm Oe and 1 nC/Oe under a notably low dc magnetic bias of 2 Oe; at resonance, these coefficients were dramatically increased to 400 V/cm Oe and 42 nC/Oe, respectively. These values are much higher, and the required dc magnetic bias much lower, than those of previously reported Terfenol-D based ME laminates.

  19. Optical micromachined ultrasound transducers (OMUT)--a new approach for high-frequency transducers.

    PubMed

    Tadayon, Mohammad Amin; Ashkenazi, Shai

    2013-09-01

    The sensitivity and reliability of piezoelectric ultrasound transducers severely degrade in applications requiring high frequency and small element size. Alternative technologies such as capacitive micromachined ultrasound transducers (CMUT) and optical sensing and generation of ultrasound have been proposed and studied for several decades. In this paper, we present a new type of device based on optical micromachined ultrasound transducer (OMUT) technology. OMUTs rely on microfabrication techniques to construct micrometerscale air cavities capped by an elastic membrane. A modified photoresist bonding process has been developed to facilitate the fabrication of these devices. We will describe the design, fabrication, and testing of prototype OMUT devices which implement a receive-only function. Future design modifications are proposed for incorporating complete transmit¿receive functionality in a single element. PMID:24658733

  20. Note: Comparative experimental studies on the performance of 2-2 piezocomposite for medical ultrasound transducers.

    PubMed

    Marinozzi, F; Bini, F; Biagioni, A; Grandoni, A; Spicci, L

    2013-09-01

    The paper reports the experimental investigation of the behavior of 2-2 Lead Zirconate Titanate (PZT)-polymer composite transducers array for clinical ultrasound equipments. Several 2-2 plate composites having the same dicing pitch of 0.11 mm and different volume fractions were manufactured and investigated. Measurements were performed through different techniques such as electrical impedance, pulse-echo, and Laser Doppler Vibrometer. With the last one, maps of the surface displacement were presented relative to thickness mode and first lateral mode resonance frequencies. The transducers with volume fractions of the 40% resulted markedly inefficient, whereas the largest bandwidth and best band shape were achieved by the 50%. PMID:24089885

  1. FEM Modeling of a Magnetoelectric Transducer for Autonomous Micro Sensors in Medical Application

    NASA Astrophysics Data System (ADS)

    Yang, Gang; Talleb, Hakeim; Gensbittel, Aurélie; Ren, Zhuoxiang

    2015-11-01

    In the context of wireless and autonomous sensors, this paper presents the multiphysics modeling of an energy transducer based on magnetoelectric (ME) composite for biomedical applications. The study considers the power requirement of an implanted sensor, the communication distance, the size limit of the device for minimal invasive insertion as well as the electromagnetic exposure restriction of the human body. To minimize the electromagnetic absorption by the human body, the energy source is provided by an external reader emitting low frequency magnetic field. The modeling is carried out with the finite element method by solving simultaneously the multiple physics problems including the electric load of the conditioning circuit. The simulation results show that with the T-L mode of a trilayer laminated ME composite, the transducer can deliver the required energy in respecting different constraints.

  2. Composites

    NASA Astrophysics Data System (ADS)

    Taylor, John G.

    The Composites market is arguably the most challenging and profitable market for phenolic resins aside from electronics. The variety of products and processes encountered creates the challenges, and the demand for high performance in critical operations brings value. Phenolic composite materials are rendered into a wide range of components to supply a diverse and fragmented commercial base that includes customers in aerospace (Space Shuttle), aircraft (interiors and brakes), mass transit (interiors), defense (blast protection), marine, mine ducting, off-shore (ducts and grating) and infrastructure (architectural) to name a few. For example, phenolic resin is a critical adhesive in the manufacture of honeycomb sandwich panels. Various solvent and water based resins are described along with resin characteristics and the role of metal ions for enhanced thermal stability of the resin used to coat the honeycomb. Featured new developments include pultrusion of phenolic grating, success in RTM/VARTM fabricated parts, new ballistic developments for military vehicles and high char yield carbon-carbon composites along with many others. Additionally, global regional market resin volumes and sales are presented and compared with other thermosetting resin systems.

  3. 1,3-Propanediol production from glycerol with Lactobacillus diolivorans.

    PubMed

    Pflügl, Stefan; Marx, Hans; Mattanovich, Diethard; Sauer, Michael

    2012-09-01

    The aim of this study was to evaluate the natural producer Lactobacillus diolivorans as potential production organism of 1,3-propanediol from glycerol. Different cultivation parameters, such as oxygen supply, feeding-strategy, or medium composition have been tested in batch and fed-batch cultivations. The 1,3-propanediol concentration obtained in batch cultivations was 41.7 g/l. This could be increased to 73.7 g/l in a fed-batch co-feeding glucose and glycerol with a molar ratio of 0.1. Yeast extract as part of the MRS cultivation medium could be replaced by nicotinic acid and riboflavin. Furthermore, the addition of Vitamin B(12) to the culture medium increased production by 15% to a final titer of 84.5 g/l 1,3-propanediol. PMID:22728193

  4. A high-temperature wideband pressure transducer

    NASA Technical Reports Server (NTRS)

    Zuckerwar, A. J.

    1975-01-01

    Progress in the development of a pressure transducer for measurement of the pressure fluctuations in the high temperature environment of a jet exhaust is reported. A condenser microphone carrier system was adapted to meet the specifications. A theoretical analysis is presented which describes the operation of the condenser microphone in terms of geometry, materials, and other physical properties. The analysis was used as the basis for design of a prototype high temperature microphone. The feasibility of connecting the microphone to a converter over a high temperature cable operating as a half-wavelength transmission line was also examined.

  5. Liquid-immersible electrostatic ultrasonic transducer

    NASA Technical Reports Server (NTRS)

    Cantrell, J. H., Jr.; Heyman, J. S.; Yost, W. T.; Torbett, M. A.; Breazeale, M. A. (Inventor)

    1982-01-01

    A broadband megahertz range electrostatic acoustic transducer for use in a liquid environment is described. A liquid tight enclosure includes a metallic conducting membrane as part of its outside surface and has a means inside the liquid tight enclosure for applying a tension to the membrane and for mounting an electrode such that the flat end of the electrode is aproximately parallel to the membrane. The invention includes structure and a method for ensuring that the membrane and the flat end of the electrode are exactly parallel and a fixed predetermined distance from each other.

  6. HEALTH ASSESSMENT OF 1,3-BUTADIENE

    EPA Science Inventory

    This assessment was conducted to review the new information that has become available since EPA's 1985 health assessment of 1,3-butadiene.

    1,3-Butadiene is a gas used commercially in the production of styrene-butadiene rubber, plastics, and thermoplastic resins. The major...

  7. 41 CFR 60-1.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 41 Public Contracts and Property Management 1 2010-07-01 2010-07-01 true Definitions. 60-1.3 Section 60-1.3 Public Contracts and Property Management Other Provisions Relating to Public Contracts OFFICE OF FEDERAL CONTRACT COMPLIANCE PROGRAMS, EQUAL EMPLOYMENT OPPORTUNITY, DEPARTMENT OF LABOR 1-OBLIGATIONS OF CONTRACTORS AND...

  8. 36 CFR 1.3 - Penalties.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Penalties. 1.3 Section 1.3 Parks, Forests, and Public Property NATIONAL PARK SERVICE, DEPARTMENT OF THE INTERIOR GENERAL PROVISIONS... 1 through 7, 12 and 13 of this chapter, within a park area not covered in paragraphs (b) or (c)...

  9. 45 CFR 1206.1-3 - Definitions.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 45 Public Welfare 4 2013-10-01 2013-10-01 false Definitions. 1206.1-3 Section 1206.1-3 Public Welfare Regulations Relating to Public Welfare (Continued) CORPORATION FOR NATIONAL AND COMMUNITY SERVICE GRANTS AND CONTRACTS-SUSPENSION AND TERMINATION AND DENIAL OF APPLICATION FOR REFUNDING Suspension and Termination of Assistance §...

  10. Beam profile measurements and simulations for ultrasonic transducers operating in air

    PubMed

    Benny; Hayward; Chapman

    2000-04-01

    This paper outlines a method that has been implemented to predict and measure the acoustic radiation generated by ultrasonic transducers operating into air in continuous wave mode. Commencing with both arbitrary surface displacement data and radiating aperture, the transmitted pressure beam profile is obtained and includes simulation of propagation channel attenuation and where necessary, the directional response of any ultrasonic receiver. The surface displacement data may be derived directly, from laser measurement of the vibrating surface, or indirectly, from finite element modeling of the transducer configuration. To validate the approach and to provide experimental measurement of transducer beam profiles, a vibration-free, draft-proof scanning system that has been installed within an environmentally controlled laboratory is described. A comparison of experimental and simulated results for piezoelectric composite, piezoelectric polymer, and electrostatic transducers is then presented to demonstrate some quite different airborne ultrasonic beam-profile characteristics. Good agreement between theory and experiment is obtained. The results are compared with those expected from a classical aperture diffraction approach and the reasons for any significant differences are explained. PMID:10790035

  11. Dual-resonance converse magnetoelectric and voltage step-up effects in laminated composite of long-type 0.71Pb(Mg1/3Nb2/3)O3-0.29PbTiO3 piezoelectric single-crystal transformer and Tb0.3Dy0.7Fe1.92 magnetostrictive alloy bars

    NASA Astrophysics Data System (ADS)

    Ming Leung, Chung; Wing Or, Siu; Wang, Feifei; Ho, S. L.

    2011-05-01

    We report a dual-resonance converse magnetoelectric effect and a dual-resonance voltage step-up effect in a laminated composite made by sandwiching the output (or secondary) section of a long-type 0.71Pb(Mg1/3Nb2/3)O3-0.29PbTiO3 (PMN-PT) piezoelectric single-crystal transformer having a longitudinal-longitudinal polarization between two Tb0.3Dy0.7Fe1.92 (Terfenol-D) magnetostrictive alloy bars having a longitudinal magnetization. The reported converse magnetoelectric effect originates from the mechanically mediated resonance converse piezoelectric effect in the PMN-PT transformer and resonance converse magnetostrictive effect in the Terfenol-D bars. The additional voltage step-up effect results from the mechanically mediated resonance converse and direct piezoelectric effects in the PMN-PT transformer. The composite shows two sharp resonance peaks of 0.39 and 0.54 G/V in converse magnetoelectric coefficient (αB = dB/dVin) and of 1.4 and 2.1 in voltage step-up ratio (Vout/Vin) at about 54 and 120 kHz, corresponding to the half- and full-wavelength longitudinal mode resonances, respectively. The measured magnetic induction (B) exhibits good linear relationships to the applied ac voltage (Vin) with amplitude varying from 10 to 100 V in both resonance and nonresonance conditions. These dual-resonance effects make the composite great promise for coil-free electromagnetic device applications.

  12. Synthesis of 1,3,3-trinitroazetidine

    DOEpatents

    Hiskey, M.A.; Coburn, M.D.

    1994-08-09

    A process of preparing 1,3,3-trinitroazetidine includes forming a 5-hydroxymethyl-5-nitro-1-alkyltetrahydro-1,3-oxazine, e.g., reacting a 1,3,5-trialkyl hexahydrotriazine and tris(hydroxymethyl)nitromethane, ring opening said 5-hydroxymethyl-5-nitro-1-alkyltetrahydro-1,3-oxazine to form a 3-alkylamino-2-hydroxymethyl-2-nitro-1-propanol salt, ring closing said 3-alkylamino-2-hydroxymethyl-2-nitro-1-propanol salt to form a 3-hydroxymethyl-3-nitro-1-alkylazetidine salt, nitrating said 3-hydroxymethyl-3-nitro-1-alkylazetidine salt to form a 1-alkyl-3,3-dinitroazetidine, and converting said 1-alkyl-3,3-dinitroazetidine into 1,3,3-trinitroazetidine is disclosed. 1 fig.

  13. Synthesis of 1,3,3-trinitroazetidine

    DOEpatents

    Hiskey, Michael A.; Coburn, Michael D.

    1994-01-01

    A process of preparing 1,3,3-trinitroazetidine including forming a 5-hydroxymethyl-5-nitro-1-alkyltetrahydro-1,3-oxazine, e.g., reacting a 1,3,5-trialkyl hexahydrotriazine and tris(hydroxymethyl)nitromethane, ring opening said 5-hydroxymethyl-5-nitro-1-alkyltetrahydro-1,3-oxazine to form a 3-alkylamino-2-hydroxymethyl-2-nitro-1-propanol salt, ring closing said 3-alkylamino-2-hydroxymethyl-2-nitro-1-propanol salt to form a 3-hydroxymethyl-3-nitro-1-alkylazetidine salt, nitrating said 3-hydroxymethyl-3-nitro-1-alkylazetidine salt to form a 1-alkyl-3,3-dinitroazetidine, and converting said 1-alkyl-3,3-dinitroazetidine into 1,3,3-trinitroazetidine is disclosed.

  14. Composites

    NASA Astrophysics Data System (ADS)

    Chmielewski, M.; Nosewicz, S.; Pietrzak, K.; Rojek, J.; Strojny-Nędza, A.; Mackiewicz, S.; Dutkiewicz, J.

    2014-11-01

    It is commonly known that the properties of sintered materials are strongly related to technological conditions of the densification process. This paper shows the sintering behavior of a NiAl-Al2O3 composite, and its individual components sintered separately. Each kind of material was processed via the powder metallurgy route (hot pressing). The progress of sintering at different stages of the process was tested. Changes in the microstructure were examined using scanning and transmission electron microscopy. Metal-ceramics interface was clean and no additional phases were detected. Correlation between the microstructure, density, and mechanical properties of the sintered materials was analyzed. The values of elastic constants of NiAl/Al2O3 were close to intermetallic ones due to the volume content of the NiAl phase particularly at low densities, where small alumina particles had no impact on the composite's stiffness. The influence of the external pressure of 30 MPa seemed crucial for obtaining satisfactory stiffness for three kinds of the studied materials which were characterized by a high dense microstructure with a low number of isolated spherical pores.

  15. Embedded ultrasonic transducers for active and passive concrete monitoring.

    PubMed

    Niederleithinger, Ernst; Wolf, Julia; Mielentz, Frank; Wiggenhauser, Herbert; Pirskawetz, Stephan

    2015-01-01

    Recently developed new transducers for ultrasonic transmission, which can be embedded right into concrete, are now used for non-destructive permanent monitoring of concrete. They can be installed during construction or thereafter. Large volumes of concrete can be monitored for changes of material properties by a limited number of transducers. The transducer design, the main properties as well as installation procedures are presented. It is shown that compressional waves with a central frequency of 62 kHz are mainly generated around the transducer's axis. The transducer can be used as a transmitter or receiver. Application examples demonstrate that the transducers can be used to monitor concrete conditions parameters (stress, temperature, …) as well as damages in an early state or the detection of acoustic events (e.g., crack opening). Besides application in civil engineering our setups can also be used for model studies in geosciences. PMID:25923928

  16. Floating Ultrasonic Transducer Inspection System and Method for Nondestructive Evaluation

    NASA Technical Reports Server (NTRS)

    Zalameda, Joseph N. (Inventor); Johnston, Patrick H. (Inventor)

    2016-01-01

    A method for inspecting a structural sample using ultrasonic energy includes positioning an ultrasonic transducer adjacent to a surface of the sample, and then transmitting ultrasonic energy into the sample. Force pulses are applied to the transducer concurrently with transmission of the ultrasonic energy. A host machine processes ultrasonic return pulses from an ultrasonic pulser/receiver to quantify attenuation of the ultrasonic energy within the sample. The host machine detects a defect in the sample using the quantified level of attenuation. The method may include positioning a dry couplant between an ultrasonic transducer and the surface. A system includes an actuator, an ultrasonic transducer, a dry couplant between the transducer the sample, a scanning device that moves the actuator and transducer, and a measurement system having a pulsed actuator power supply, an ultrasonic pulser/receiver, and a host machine that executes the above method.

  17. Electronic scanning pressure measuring system and transducer package

    NASA Technical Reports Server (NTRS)

    Coe, C. F. (Inventor); Parra, G. T.

    1984-01-01

    An electronic scanning pressure system that includes a plurality of pressure transducers is examined. A means obtains an electrical signal indicative of a pressure measurement from each of the plurality of pressure transducers. A multiplexing means is connected for selectivity supplying inputs from the plurality of pressure transducers to the signal obtaining means. A data bus connects the plurality of pressure transducers to the multiplexing means. A latch circuit is connected to supply control inputs to the multiplexing means. An address bus is connected to supply an address signal of a selected one of the plurality of pressure transducers to the latch circuit. In operation, each of the pressure transducers is successively scanned by the multiplexing means in response to address signals supplied on the address bus to the latch circuit.

  18. Using FOCUS to determine the radiation impedance for square transducers

    NASA Astrophysics Data System (ADS)

    Jennings, Matthew R.; McGough, Robert J.

    2012-10-01

    The power radiated by an ultrasound transducer is calculated with the radiation resistance, which is the real part of the radiation impedance. For circular transducers, an analytical solution for the radiation impedance is known, but an analytical expression for the radiation impedance is not available for rectangular or square transducers. To determine the radiation resistance in FOCUS, the pressure on the surface of a square transducer is computed with the fast nearfield method, and then the force on the transducer face is computed by integrating the pressure. Results using this approach are numerically evaluated for a range of ka values from 0.1 to 16. The pressure on the transducer face is also computed with the Rayleigh-Sommerfeld integral, and the results are compared. The numerical value of the radiation resistance computed with FOCUS and with the Rayleigh-Sommerfeld integral converge to the same value, although FOCUS calculates the same result in about one-quarter of the time.

  19. Current transducers used in power line measurements

    NASA Astrophysics Data System (ADS)

    Milcarz, Sz.; Gołebiowski, J.

    2014-08-01

    There are many solutions used for current measurements in power lines. The study shows a transducer consisting of a ferromagnetic core, a beam placed in an air-gap and a sensor for optical readout. The beam is made of silicon with a thin 50%Ni50%Fe film. The material of the core is permalloy. A distribution of magnetic field depends on current supplying the power line. The beam is deflected due to magnetic field in the air-gap. A deflection of the beam is measured by the optical fibre sensor. Its advantage is simple design, high precision of processing, non-electric transmission, low costs and ability of a non-contact measurement. Comsol Multiphysics 4.4 and Magnetic Fields Module (mef) were used for modeling. An influence of magnetic circuit's materials and dimensions of the ferromagnetic core and the air-gap were tested in order to determine the most sufficient distribution of magnetic field in the air-gap. The study shows results of the modeling of the transducer compared to practical results for a similar construction scaled down to lower current values.

  20. Development of Terfenol-D transducer material

    NASA Astrophysics Data System (ADS)

    Lindgren, E. A.; Haroush, S.; Poret, J. C.; Mazzatesta, A. D.; Rosen, M.; Wun-Fogle, M.; Restorff, J. B.; Clark, A. E.; Lindberg, J. F.

    1998-06-01

    Terfenol-D, Tb1-xDyxFe2 (x≅0.7), is successfully used as a magnetostrictive transducer material for low-frequency applications. To extend the frequency range of magnetostrictive transducers into the high kHz and MHz range, new materials processing techniques must be developed to minimize eddy current losses. The method that has demonstrated the greatest potential to date is based on rapid solidification by melt spinning to obtain thin strips of material. The objective of this program includes refining the casting procedure to yield ribbons with the [111] direction oriented along the length of the ribbon, with the (110) plane in the plane of the ribbon. The crystallographic orientation of the Terfenol-D ribbons have been controlled by varying the cooling rate of the melt-spinning process. The cooling rates were controlled by a number of parameters in the melt-spinning process and ribbons have been obtained with an enhancement of the (110) plane parallel to the surface of the ribbon. Magnetostrictive measurements under tensile stresses up to 3 MPa and magnetic fields up to 4 kOe yielded magnetostrictive displacements of 850×10-6.

  1. Capacitive micromachined ultrasonic transducers: fabrication technology.

    PubMed

    Ergun, Arif Sanli; Huang, Yongli; Zhuang, Xuefeng; Oralkan, Omer; Yaralioglu, Goksen G; Khuri-Yakub, Butrus T

    2005-12-01

    Capacitive micromachined ultrasonic transducer (cMUT) technology is a prime candidate for next generation imaging systems. Medical and underwater imaging and the nondestructive evaluation (NDE) societies have expressed growing interest in cMUTs over the years. Capacitive micromachined ultrasonic transducer technology is expected to make a strong impact on imaging technologies, especially volumetric imaging, and to appear in commercial products in the near future. This paper focuses on fabrication technologies for cMUTs and reviews and compares variations in the production processes. We have developed two main approaches to the fabrication of cMUTs: the sacrificial release process and the recently introduced wafer-bonding method. This paper gives a thorough review of the sacrificial release processes, and it describes the new wafer-bonding method in detail. Process variations are compared qualitatively and quantitatively whenever possible. Through these comparisons, it was concluded that wafer-bonded cMUT technology was superior in terms of process control, yield, and uniformity. Because the number of steps and consequent process time were reduced (from six-mask process to four-mask process), turn-around time was improved significantly. PMID:16463490

  2. Acoustic lens for capacitive micromachined ultrasonic transducers

    NASA Astrophysics Data System (ADS)

    Chang, Chienliu; Firouzi, Kamyar; Park, Kwan Kyu; Sarioglu, Ali Fatih; Nikoozadeh, Amin; Yoon, Hyo-Seon; Vaithilingam, Srikant; Carver, Thomas; Khuri-Yakub, Butrus T.

    2014-08-01

    Capacitive micromachined ultrasonic transducers (CMUTs) have great potential to compete with traditional piezoelectric transducers in therapeutic ultrasound applications. In this paper we have designed, fabricated and developed an acoustic lens formed on the CMUT to mechanically focus ultrasound. The acoustic lens was designed based on the paraxial theory and made of silicone rubber for acoustic impedance matching and encapsulation. The CMUT was fabricated based on the local oxidation of silicon (LOCOS) and fusion-bonding. The fabricated CMUT was verified to behave like an electromechanical resonator in air and exhibited wideband response with a center frequency of 2.2 MHz in immersion. The fabrication for the acoustic lens contained two consecutive mold castings and directly formed on the surface of the CMUT. Applied with ac burst input voltages at the center frequency, the CMUT with the acoustic lens generated an output pressure of 1.89 MPa (peak-to-peak) at the focal point with an effective focal gain of 3.43 in immersion. Compared to the same CMUT without a lens, the CMUT with the acoustic lens demonstrated the ability to successfully focus ultrasound and provided a viable solution to the miniaturization of the multi-modality forward-looking endoscopes without electrical focusing.

  3. Electret Acoustic Transducer Array For Computerized Ultrasound Risk Evaluation System

    DOEpatents

    Moore, Thomas L.; Fisher, Karl A.

    2005-08-09

    An electret-based acoustic transducer array is provided and may be used in a system for examining tissue. The acoustic transducer array is formed with a substrate that has a multiple distinct cells formed therein. Within each of the distinct cells is positioned an acoustic transducing element formed of an electret material. A conductive membrane is formed over the distinct cells and may be flexible.

  4. Low-cost ultrasonic lamb-wave transducer

    NASA Technical Reports Server (NTRS)

    Kammerer, C. C.

    1978-01-01

    Transducer propagates Lamb wave through thin aluminum sheet material. Model includes two elements that measure effects of damping and loading which, in turn, are indirectly equated to bond integrity. Transducer has been used to evaluate bond integrity of aluminum facing adhesively bonded to aluminum facing. Because of versatility, it is now possible to inspect many objects of different configurations that could not be reached with earlier transducers.

  5. An ultrasonic transducer with Gaussian radial velocity distribution

    NASA Technical Reports Server (NTRS)

    Zerwekh, P. S.; Claus, R. O.

    1981-01-01

    A transducer with a velocity profile which is Gaussian as a function of radius and independent of angle is described. In materials evaluation applications requiring the interrogation of modified far field patterns of an ultrasonic transducer, it is desirable to use a transducer which produces a beam with a Gaussian profile. A computer aided electrode design and calibrated three dimensional interferometric optical and ultrasonic measurements of the far field distribution are presented.

  6. Comparative study of acceleration transducers for biomedical applications

    NASA Astrophysics Data System (ADS)

    Buchczik, Dariusz; Wyżgolik, Roman; Pietraszek, Stanisław

    2006-10-01

    The results of comparative studies of the metrological parameters of acceleration transducers constructed in Institute of Electronics, Silesian University of Technology is presented in this article. The construction of the transducers is based on commercially available monolithic accelerometers and optimized for biomedical applications. The parameters determined during the tests are similar to the parameters of the monolithic accelerometers declared by their manufacturers. It proofs that both the mechanical and the electronic construction of the transducers are correct.

  7. Fabrication of a PMN-PT Single Crystal-Based Transcranial Doppler Transducer and the Power Regulation of Its Detection System

    PubMed Central

    Yue, Qingwen; Liu, Dongxu; Wang, Wei; Di, Wenning; Lin, Di; Wang, Xi'an; Luo, Haosu

    2014-01-01

    Doppler sonographic measurement of flow velocity in the basal cerebral arteries through the intact skull was developed using a pulsed Doppler technique and 2 MHz emitting frequency. Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) were chosen to be the piezoelectric transducer material due to their ultrahigh piezoelectric coefficients, high electromechanical coupling coefficients and low dielectric loss. The pulse-echo response of the transducer was measured using the conventional pulse-echo method in a water bath at room temperature. The −6 dB bandwidth of the transducer is 68.4% and the sensitivity is −17.4 dB. In order to get a good match between transducer and detection system, different transmission powers have been regulated by changing the impedance of the transmitting electric circuit. In the middle cerebral artery (MCA) measurement photograph results, as the transmission power is increasing, the detection results become clearer and clearer. A comparison at the same transmission power for different transducers shows that the detection photograph obtained by the crystal transducer was clearer than that obtained with a commercial transducer, which should make it easier for doctors to find the cerebral arteries. PMID:25536000

  8. Fabrication of a PMN-PT single crystal-based transcranial Doppler transducer and the power regulation of its detection system.

    PubMed

    Yue, Qingwen; Liu, Dongxu; Wang, Wei; Di, Wenning; Lin, Di; Wang, Xi'an; Luo, Haosu

    2014-01-01

    Doppler sonographic measurement of flow velocity in the basal cerebral arteries through the intact skull was developed using a pulsed Doppler technique and 2 MHz emitting frequency. Relaxor-based ferroelectric single crystals Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) were chosen to be the piezoelectric transducer material due to their ultrahigh piezoelectric coefficients, high electromechanical coupling coefficients and low dielectric loss. The pulse-echo response of the transducer was measured using the conventional pulse-echo method in a water bath at room temperature. The -6 dB bandwidth of the transducer is 68.4% and the sensitivity is -17.4 dB. In order to get a good match between transducer and detection system, different transmission powers have been regulated by changing the impedance of the transmitting electric circuit. In the middle cerebral artery (MCA) measurement photograph results, as the transmission power is increasing, the detection results become clearer and clearer. A comparison at the same transmission power for different transducers shows that the detection photograph obtained by the crystal transducer was clearer than that obtained with a commercial transducer, which should make it easier for doctors to find the cerebral arteries. PMID:25536000

  9. Modeling of multilayered piezoelectric transducers with ultrasonic welding application

    NASA Astrophysics Data System (ADS)

    Güney, Murat; Eskinat, Esref

    2007-04-01

    Mechanical components of sandwiched piezoelectric transducers are modeled using one-dimensional wave transmission and piezoelectric equations. Using the impedance method, resonance frequencies, stress and displacement distributions along the multilayered piezoelectric transducers of different dimensions and materials are obtained. The calculated resonance frequencies and the impedances are experimentally verified. For ultrasonic welding of plastics, the effect of the parts to be welded on the resonance frequency of the whole system is investigated regarding both material damping and piezoelectric losses. Using the methods developed, several piezoelectric transducers are analysed for different designs. The obtained results can be used to better understand the qualitative relations between the design variables of ultrasonic piezoelectric transducers.

  10. High Temperature Ultrasonic Transducer for Real-time Inspection

    NASA Astrophysics Data System (ADS)

    Amini, Mohammad Hossein; Sinclair, Anthony N.; Coyle, Thomas W.

    A broadband ultrasonic transducer with a novel porous ceramic backing layer is introduced to operate at 700 °C. 36° Y-cut lithium niobate (LiNbO3) single crystal was selected for the piezoelectric element. By appropriate choice of constituent materials, porosity and pore size, the acoustic impedance and attenuation of a zirconia-based backing layer were optimized. An active brazing alloy with high temperature and chemical stability was selected to bond the transducer layers together. Prototype transducers have been tested at temperatures up to 700 °C. The experiments confirmed that transducer integrity was maintained.

  11. Radiation endurance of piezoelectric ultrasonic transducers--a review.

    PubMed

    Sinclair, A N; Chertov, A M

    2015-03-01

    A literature survey is presented on the radiation endurance of piezoelectric ultrasonic transducer components and complete transducer assemblies, as functions of cumulative gamma dose and neutron fluence. The most extensive data on this topic has been acquired in CANDU electrical generating stations, which use piezoelectric ultrasonic transducers manufactured commercially with minor accommodation for high radiation fields. They have been found to be reliable for cumulative gamma doses of up to approximately 2 MegaGrays; a brief summary is made of the associated accommodations required to the transducer design, and the ultimate expected failure modes. Outside of the CANDU experience, endurance data have been acquired under a diverse spectrum of operating conditions; this can impede a direct comparison of the information from different sources. Much of this data is associated with transducers immersed in liquid metal coolants associated with advanced reactor designs. Significant modifications to conventional designs have led to the availability of custom transducers that can endure well over 100 MegaGrays of cumulative gamma dose. Published data on transducer endurance against neutron fluence are reviewed, but are either insufficient, or were reported with inadequate description of test conditions, to make general conclusions on transducer endurance with high confidence. Several test projects are planned or are already underway by major laboratories and research consortia to augment the store of transducer endurance data with respect to both gamma and neutron radiation. PMID:25482533

  12. Electrical characterization of coupled and uncoupled MEMS ultrasonic transducers.

    PubMed

    Oppenheim, Irving J; Jain, Akash; Greve, David W

    2003-03-01

    We report electrical characterization of micromachined polysilicon capacitive diaphragms for use as ultrasonic transducers. Admittance measurements yield insight into the resonant behavior and also the damping resulting from ultrasonic radiation and frictional forces caused by the etch release holes. Unbonded transducers exhibit sharp resonances with Q values that increase with decreasing air pressure. We also report for the first time direct bonding of these transducers to solid surfaces. Transducers survive the bonding process and show distinctly different displacement in response to applied dc bias. Finally, a single-degree-of-freedom model is used to obtain insight into the various contributions to damping. PMID:12699163

  13. Evaluation of several ultrasonic flowmeter transducers in cryogenic environment

    NASA Technical Reports Server (NTRS)

    Moughon, W. C.

    1981-01-01

    Eighteen piezoelectric ultrasonic flowmeter transducers were laboratory tested to determine their suitability and long range reliability for use by the National Transonic Facility (NTF) to measure the flow rate of 450 Kg/sec of liquid nitrogen (LN2). Tests included thermally cycling each transducer 50 to 150 times over a temperature range of 295 K (ambient) to 77 K (LN2). The transducers were submerged in liquid nitrogen for 1 to 4 hours and the signal strength and quality noted. Results disclose that the current state-of-the-art ultrasonic flow transducers are very reliable and will meet the stringent requirements of the NTF.

  14. Evaluation of several ultrasonic flowmeter transducers in cryogenic environment

    NASA Astrophysics Data System (ADS)

    Moughon, W. C.

    1981-04-01

    Eighteen piezoelectric ultrasonic flowmeter transducers were laboratory tested to determine their suitability and long range reliability for use by the National Transonic Facility (NTF) to measure the flow rate of 450 Kg/sec of liquid nitrogen (LN2). Tests included thermally cycling each transducer 50 to 150 times over a temperature range of 295 K (ambient) to 77 K (LN2). The transducers were submerged in liquid nitrogen for 1 to 4 hours and the signal strength and quality noted. Results disclose that the current state-of-the-art ultrasonic flow transducers are very reliable and will meet the stringent requirements of the NTF.

  15. A new transducer system for direct motor unit force measurement.

    PubMed

    Turkawski, S J; van Ruijven, L J; van Kuyen, M; Schreurs, A W; Weijs, W A

    1996-11-01

    A new transducer was developed for in situ measurement of the force vector in a complex muscle. The transducer measures the magnitude, and the line of action of a force in a single plane. The dynamic range of the transducer is 0-5 N. This range includes the small forces developed by an active motor unit and the relatively large passive force of a whole muscle. In this study we present the details of the transducer design and specifications, and describe its application in the measurement of motor unit forces of the rabbit masseter muscle. PMID:8894930

  16. Compact piezoelectric transducer fiber scanning probe for optical coherence tomography.

    PubMed

    Zhang, Ning; Tsai, Tsung-Han; Ahsen, Osman O; Liang, Kaicheng; Lee, Hsiang-Chieh; Xue, Ping; Li, Xingde; Fujimoto, James G

    2014-01-15

    We developed a compact, optical fiber scanning piezoelectric transducer (PZT) probe for endoscopic and minimally invasive optical coherence tomography (OCT). Compared with previous forward-mount fiber designs, we present a reverse-mount design that achieves a shorter rigid length. The fiber was mounted at the proximal end of a quadruple PZT tube and scanned inside the hollow PZT tube to reduce the probe length. The fiber resonant frequency was 338 Hz using a 17-mm-long fiber. A 0.9 mm fiber deflection was achieved with a driving amplitude of 35 V. Using a GRIN lens-based optical design with a 1.3× magnification, a ∼6 μm spot was scanned over a 1.2 mm diameter field. The probe was encased in a metal hypodermic tube with a ∼25 mm rigid length and covered with a 3.2 mm outer diameter (OD) plastic sheath. Imaging was performed with a swept source OCT system based on a Fourier domain modelocked laser (FDML) light source at a 240 kHz axial scan rate and 8 μm axial resolution (in air). En face OCT imaging of skin in vivo and human colon ex vivo was demonstrated. PMID:24562102

  17. 21 CFR 1.3 - Definitions.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... REGULATIONS § 1.3 Definitions. (a) Labeling includes all written, printed, or graphic matter accompanying an... delivery in interstate commerce. (b) Label means any display of written, printed, or graphic matter on...

  18. HANSF 1.3 user's manual

    SciTech Connect

    PLYS, M.G.

    1999-05-21

    The HANSF analysis tool is an integrated model considering phenomena inside a multi-canister overpack (MCO) spent nuclear fuel container such as fuel oxidation, convective and radiative heat transfer, and the potential for fission product release. It may be used for all phases of spent fuel disposition including cold vacuum drying, transportation, and storage. This manual reflects HANSF version 1.3, a revised version of version 1.2a. HANSF 1.3 was written to add new models for axial nodalization, add new features for ease of usage, and correct errors. HANSF 1.3 is intended for use on personal computers such as IBM-compatible machines with Intel processors running under a DOS-type operating system. HANSF 1.3 is known to compile under Lahey TI and Digital Visual FORTRAN, Version 6.0, but this does not preclude operation in other environments.

  19. 17 CFR 1.3 - Definitions.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... Editorial Note: For Federal Register citations affecting § 1.3, see the List of CFR Sections Affected, which.... (e) Commodity. This term means and includes wheat, cotton, rice, corn, oats, barley, rye,...

  20. Highly reliable multisensor array (MSA) smart transducers

    NASA Astrophysics Data System (ADS)

    Perotti, José; Lucena, Angel; Mackey, Paul; Mata, Carlos; Immer, Christopher

    2006-05-01

    Many developments in the field of multisensor array (MSA) transducers have taken place in the last few years. Advancements in fabrication technology, such as Micro-Electro-Mechanical Systems (MEMS) and nanotechnology, have made implementation of MSA devices a reality. NASA Kennedy Space Center (KSC) has been developing this type of technology because of the increases in safety, reliability, and performance and the reduction in operational and maintenance costs that can be achieved with these devices. To demonstrate the MSA technology benefits, KSC quantified the relationship between the number of sensors (N) and the associated improvement in sensor life and reliability. A software algorithm was developed to monitor and assess the health of each element and the overall MSA. Furthermore, the software algorithm implemented criteria on how these elements would contribute to the MSA-calculated output to ensure required performance. The hypothesis was that a greater number of statistically independent sensor elements would provide a measurable increase in measurement reliability. A computer simulation was created to answer this question. An array of N sensors underwent random failures in the simulation and a life extension factor (LEF equals the percentage of the life of a single sensor) was calculated by the program. When LEF was plotted as a function of N, a quasiexponential behavior was detected with marginal improvement above N = 30. The hypothesis and follow-on simulation results were then corroborated experimentally. An array composed of eight independent pressure sensors was fabricated. To accelerate sensor life cycle and failure and to simulate degradation over time, the MSA was exposed to an environmental tem-perature of 125°C. Every 24 hours, the experiment's environmental temperature was returned to ambient temperature (27°C), and the outputs of all the MSA sensor elements were measured. Once per week, the MSA calibration was verified at five different

  1. Microscale 1–3-Type (Na,K)NbO3-Based Pb-Free Piezocomposites for High-Frequency Ultrasonic Transducer Applications

    PubMed Central

    Shen, Zong-Yang; Li, Jing-Feng; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk

    2011-01-01

    Fine-grained Pb-free (Na0.535K0.485)0.95Li0.05(Nb0.8Ta0.2)O3 (NKLNT) piezoceramics prepared by spark plasma sintering (SPS) technique was used to fabricate NKLNT/epoxy 1–3 composites with a modified dice–fill method. Because of its good machinability, SPSed NKLNT ceramic rods could be miniaturized to a lateral width of 50 µm. After lapping down to 56 µm in thickness, the composite was used to fabricate an ultrasonic transducer as the active piezoelectric element. This composite transducer showed a bandwidth at −6 dB nearly 90%at a center frequency of 29 MHz, demonstrating that this Pb-free composite thick film is very promising for the fabrication of high-frequency ultrasonic transducers in medical imaging applications. PMID:21637726

  2. Synthesis and characterization of LiCo1/3Mn1/3Fe1/3PO4/C nanocomposite cathode of lithium batteries with high rate performance

    NASA Astrophysics Data System (ADS)

    Akimoto, Sou; Taniguchi, Izumi

    2013-11-01

    Olivine structured LiCo1/3Mn1/3Fe1/3PO4/C nanocomposites were prepared by a combination of spray pyrolysis at 300 °C and wet ball-milling followed by heat treatment at 500 °C for 4 h in a 3%H2 + N2 atmosphere. The formation of a solid solution between LiCoPO4, LiMnPO4, and LiFePO4 at this composition was confirmed by X-ray diffraction analysis. Scanning electron microscopy and transmission electron microscopy with equipped energy dispersive spectroscopy verified that the LiCo1/3Mn1/3Fe1/3PO4/C nanocomposites were agglomerates of LiCo1/3Mn1/3Fe1/3PO4 primary particles with a geometric mean diameter of 107 nm and a uniform chemical composition, and carbon was well distributed on the surface of the agglomerates. The LiCo1/3Mn1/3Fe1/3PO4/C nanocomposite cathode exhibited a high discharge capacity of 159 mAh g-1 at 0.05 C in the potential range of 2.0-5.0 V, corresponding to 94% of theoretical capacity. The capacity retention was 87% after 50 cycles at a charge-discharge rate of 1 C. Furthermore, the rate capability test showed that the high capacity still was retained even at 5 C and 20 C rate with 106 and 72 mAh g-1, respectively.

  3. Catheter tip force transducer for cardiovascular research

    NASA Technical Reports Server (NTRS)

    Feldstein, C.; Lewis, G. W.; Silver, R. H.; Culler, V. H. (Inventor)

    1976-01-01

    A force transducer for measuring dynamic force activity within the heart of a subject essentially consists of a U-shaped beam of low elastic compliance material. Two lines extend from the beams's legs and a long coil spring is attached to the beam. A strain gauge is coupled to one of the beam's legs to sense deflections thereof. The beam with the tines and most of the spring are surrounded by a flexible tube, defining a catheter, which is insertable into a subject's heart through an appropriate artery. The tines are extractable from the catheter for implantation into the myocardium by pushing on the end of the spring which extends beyond the external end of the catheter.

  4. Vertical positioning surveillance by magnetostrictive transducer

    NASA Astrophysics Data System (ADS)

    Carvalho, A. S.; Lopes, C.; Pinto, O. O.; Nunes, C. D.; Borges, M. F.; Strohaecker, T. R.

    2015-10-01

    This work purpose is to create a positioning automated system of a tailstock to perform impact resistance tests on silicone mammary implants. This system is capable to measure and oversight the positioning through interrelation between three main components: programmable logic controller, human-machine interface and magnetostrictive transducer. Together, these components form an operational closed loop that ensures an appropriate positioning for the impact device. The paper describes how the closed loop works and also the algorithm implemented in the programmable logic controller which surveys the positioning. As a last topic, the paper presents the operator work on the machine's operation in conjunction with human-machine interface. The results were satisfactory and in accordance with the limits determined on ABNT NBR ISO 14607 for this method of tests.

  5. Optically selective, acoustically resonant gas detecting transducer

    NASA Technical Reports Server (NTRS)

    Dimeff, J. (Inventor)

    1977-01-01

    A gas analyzer is disclosed which responds to the resonant absorption or emission spectrum of a specific gas by producing an acoustic resonance in a chamber containing a sample of that gas, and which measures the amount of that emission or absorption by measuring the strength of that acoustic resonance, e.g., the maximum periodic pressure, velocity or density achieved. In the preferred embodiment, a light beam is modulated periodically at the acoustical resonance frequency of a closed chamber which contains an optically dense sample of the gas of interest. Periodic heating of the absorbing gas by the light beam causes a cyclic expansion, movement, and pressure within the gas. An amplitude is reached where the increased losses were the cyclic radiation energy received. A transducing system is inclined for converting the pressure variations of the resonant gas into electronic readout signals.

  6. A symmetrical low temperature pressure transducer

    NASA Astrophysics Data System (ADS)

    Helvensteijn, B. P. M.; VanSciver, S. W.

    1990-03-01

    The design and operating characteristics of a fully differential pressure transducer are described. The device is intended for use with He II heat transfer experiments where it operates in vacuum and at low temperatures (T<4.2 K). A movable electrode is attached to two sets of miniature bellows such that the electrode position is determined by the differential pressure across the device. The movable electrode is located between two fixed electrodes, thus forming a pair of variable capacitors. A dedicated charge amplifier is used to convert the pressure induced capacitance change to an ac output voltage. The sensitivity is roughly 5 μV/Pa. For the present application, the capacitor and electronics have acceptable performance, with a mean noise level of ±5 Pa.

  7. Torsional ultrasonic transducer computational design optimization.

    PubMed

    Melchor, J; Rus, G

    2014-09-01

    A torsional piezoelectric ultrasonic sensor design is proposed in this paper and computationally tested and optimized to measure shear stiffness properties of soft tissue. These are correlated with a number of pathologies like tumors, hepatic lesions and others. The reason is that, whereas compressibility is predominantly governed by the fluid phase of the tissue, the shear stiffness is dependent on the stroma micro-architecture, which is directly affected by those pathologies. However, diagnostic tools to quantify them are currently not well developed. The first contribution is a new typology of design adapted to quasifluids. A second contribution is the procedure for design optimization, for which an analytical estimate of the Robust Probability Of Detection, called RPOD, is presented for use as optimality criteria. The RPOD is formulated probabilistically to maximize the probability of detecting the least possible pathology while minimizing the effect of noise. The resulting optimal transducer has a resonance frequency of 28 kHz. PMID:24882020

  8. Fabrication and modeling of bismuth titanate-PZT ceramic transducers for high temperature applications

    NASA Astrophysics Data System (ADS)

    Reinhardt, B.; Searfass, C.; Cyphers, R.; Sinding, K.; Pheil, C.; Tittmann, B.

    2013-01-01

    Utilization of a spray-on deposition technique of ferroelectric bismuth titanate (Bi4Ti3O12) composites has a competitive advantage to standard ultrasonic transducers. These can conform to curved surfaces, can operate at high temperature (Curie-Weiss temperature 685 °C) and are mechanically well-coupled to a substrate. However, an issue with many high temperature transducers such as bismuth titanate ceramics is that they have relatively low transduction efficiency, i.e. d33 is about 12-14 pC/F in Bi4Ti3O12 versus 650 pC/F in PZT-5H. It is a common conception that high-temperature capability comes at the cost of electro-mechanical coupling. It will be shown that the high temperature capability of bismuth-titanate-PZT composite transducers using the spray-on deposition technique previously developed, improves the electro-mechanical coupling while maintaining the high temperature performance and mechanical coupling. This material could provide advantages in harsh environments where high signal-to-noise ratios are needed.

  9. Active acoustical impedance using distributed electrodynamic transducers

    NASA Astrophysics Data System (ADS)

    Collet, M.; Berthillier, M.; David, P.

    2006-03-01

    New miniaturization and integration capabilities available from the emerging MEMS technology will allow silicon-based artificial skins involving thousands of elementary actuators to be developed in the near future. SMART structures combining large arrays of elementary motion pixels coated with macroscopic components are thus being studied so that fundamental properties such as shape, stiffness, color, and even reflectivity of light and sound could be dynamically adjusted. This paper investigates acoustic impedance capabilities of a set of distributed transducers connected with suitable controlling laws. Basically, we search to design an integrated electro-mechanical system which presents a global behavior with appropriate acoustical characteristics. This problem is intrinsically connected with the control of multi physical system based on PDE and with the notion of multi-scaled physics when we dispose MEMS devices. By using specific techniques based on partial differential equation control theory, we have first build a simple boundary control equation able to annihilate wave reflection. The obtained control strategies can also be discretized to be implemented like a zero or first order spatial operator. Thus, we can use quasi-collocated transducers and their well-known poles-zeros interlacing property to guarantee robust stability. This paper aims at showing in a first part how a well controlled semi-distributed active skin can substantially modify transmissibility or reflectivity of the corresponding homogeneous wall. In a second part numerical and experimental results underline the capabilities of the method. Finally efficiency of such a device is compared theoretically with those obtained by classical x-filtered LMS strategy.

  10. Novel Li(Ni1/3Co1/3Mn1/3)O2 cathode morphologies for high power Li-ion batteries

    NASA Astrophysics Data System (ADS)

    Oljaca, Miodrag; Blizanac, Berislav; Du Pasquier, Aurelien; Sun, Yipeng; Bontchev, Ranko; Suszko, Arek; Wall, Ryan; Koehlert, Kenneth

    2014-02-01

    In this paper, we report unique Li(Ni1/3Co1/3Mn1/3)O2 (NCM) materials produced using aerosol based liquid to solid conversion in different reactor configurations and using different atomization methods jointly termed Reactive Spray Technology (RST). A series of experiments was performed at different RST synthesis conditions suitable for large scale manufacturing to produce NCM powders with particle size ranging from 1 to ∼10 μm, varying degree of particle porosity and excellent compositional purity. The electrochemical testing in Li-ion cells indicates that NCM materials made via RST have high initial discharge capacity and good first cycle efficiency. NCM materials with small particle size and substantial intra-particle porosity show improved power rate performance at high discharge rates compared to larger particle size NCM. This was attributed to shorter diffusion length in the solid phase, increased electrochemically active surface area and high active phase accessibility due to the combined effect of smaller particle size and internal porosity. Specific capacity of small-particle NCM made by RST method was 167 mAh g-1 at 0.2 C and 137 mAh g-1 at 10 C, which compares favorably to 160 mAh g-1 at 0.2 C and 97 mAh g-1 at 10 C for NCM made by co-precipitation method having 10 μm average particle diameter.

  11. Modeling and experimental characterization on fatigue behaviour of 1-3 piezocomposites

    NASA Astrophysics Data System (ADS)

    Mohan, Y.; Jayendiran, R.; Arockiarajan, A.

    2015-04-01

    1-3 piezocomposites are very attractive materials in underwater and biomedical applications. These materials may be subjected to high electric field (2kV/mm) under continuous operation leading to deterioration in the output parameters such as remnant, saturation polarization and strain. Hence in this work, an experimental study is carried out to understand the fatigue behavior of 1-3 piezocomposites for various fiber volume fraction subjected to cyclic electric field (2kV/mm, 50Hz) up to 106 cycles. A uni-axial micro-mechanical model is developed to predict the fatigue behaviour of 1-3 piezocomposite. The novelty of this model is, the remnant polarization and strain are chosen as internal variables which is also dependent on the damage.The simulated results are compared with the experimental observations, it is observed that the proposed micro-mechanical model is able to predict the material degradation with increase in number of cycles of operation. A parametric study is also conducted for various fiber volume fraction of 1-3 piezocomposite as function of fatigue cycle it shows that the amplitude of dielectric hysteresis and butterfly loop decreases with increase in the number of cycles. The fatigue behavior has a substantial effect in the performance parameters such as coercive field, remnant polarization and the asymmetric strain behavior of 1-3 piezocomposite. This fatigue study explores the utilities of 1-3 piezocomposites in transducer applications by providing insight into the device design.

  12. Respiratory Belt Transducer Constructed Using a Singing Greeting Card Beeper

    ERIC Educational Resources Information Center

    Bhaskar, Anand; Subramani, Selvam; Ojha, Rajdeep

    2013-01-01

    An article by Belusic and Zupancic described the construction of a finger pulse sensor using a singing greeting card beeper. These authors felt that this beeper made of piezoelectric material could be easily modified to function as a respiratory belt transducer to monitor respiratory movements. Commercially available respiratory belt transducers,…

  13. Resonant acoustic transducer system for a well drilling string

    DOEpatents

    Kent, William H.; Mitchell, Peter G.

    1981-01-01

    For use in transmitting acoustic waves propagated along a well drilling string, a piezoelectric transducer is provided operating in the relatively low loss acoustic propagation range of the well drilling string. The efficiently coupled transmitting transducer incorporates a mass-spring-piezoelectric transmitter combination permitting resonant operation in the desired low frequency range.

  14. Resonant acoustic transducer system for a well drilling string

    DOEpatents

    Nardi, Anthony P.

    1981-01-01

    For use in transmitting acoustic waves propated along a well drilling string, a piezoelectric transducer is provided operating in the relatively low loss acoustic propagation range of the well drilling string. The efficiently coupled transmitting transducer incorporates a mass-spring-piezoelectric transmitter combination permitting a resonant operation in the desired low frequency range.

  15. A Force Transducer from a Junk Electronic Balance

    ERIC Educational Resources Information Center

    Aguilar, Horacio Munguia; Aguilar, Francisco Armenta

    2009-01-01

    It is shown how the load cell from a junk electronic balance can be used as a force transducer for physics experiments. Recovering this device is not only an inexpensive way of getting a valuable laboratory tool but also very useful didactic work on electronic instrumentation. Some experiments on mechanics with this transducer are possible after a…

  16. A force transducer from a junk electronic balance

    NASA Astrophysics Data System (ADS)

    Munguía Aguilar, Horacio; Armenta Aguilar, Francisco

    2009-11-01

    It is shown how the load cell from a junk electronic balance can be used as a force transducer for physics experiments. Recovering this device is not only an inexpensive way of getting a valuable laboratory tool but also very useful didactic work on electronic instrumentation. Some experiments on mechanics with this transducer are possible after a careful calibration and proper conditioning.

  17. 21 CFR 868.2900 - Gas pressure transducer.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Gas pressure transducer. 868.2900 Section 868.2900 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Monitoring Devices § 868.2900 Gas pressure transducer....

  18. How to design and construct multielement ultrasonic transducers

    NASA Technical Reports Server (NTRS)

    Burrier, R. A.; Claus, R. O.

    1984-01-01

    The practical 'how to' design and construction of multielement ultrasonic transducers are described. First, design procedures based on direct calculations of the desired acoustic field are reviewed. Second, techniques for implementing these designs using piezoelectric active elements are discussed. Finally, optical and acoustic test methods for transducer calibration are indicated.

  19. A dynamic calibration method for the pressure transducer

    NASA Astrophysics Data System (ADS)

    Wang, Zhongyu; Wang, Zhuoran; Li, Qiang

    2016-01-01

    Pressure transducer is widely used in the field of industry. A calibrated pressure transducer can increase the performance of precision instruments in the closed mechanical relationship. Calibration is the key to ensure the pressure transducer with a high precision and dynamic characteristic. Unfortunately, the current calibration method can usually be used in the laboratory with a good condition and only one pressure transducer can be calibrated at each time. Therefore the calibration efficiency is hard to meet the requirement of modern industry with high efficiency. A dynamic and fast calibration technology with a calibration device and a corresponding data processing method is proposed in this paper. Firstly, the pressure transducer to be calibrated is placed in the small cavity chamber. The calibration process only contains a single loop. The outputs of each calibrated transducer are recorded automatically by the control terminal. Secondly, LabView programming is used for the information acquisition and data processing. The performance of the repeatability and nonlinear indicators can be figured out directly. At last the pressure transducers are calibrated simultaneously in the experiment to verify the suggested calibration technology. The experimental result shows this method can be used to calibrate the pressure transducer in the practical engineering measurement.

  20. Thermal dispersion method for an ultrasonic phased-array transducer

    NASA Astrophysics Data System (ADS)

    Choi, Euna; Lee, Wonseok; Roh, Yongrae

    2016-07-01

    When the driving voltage of an ultrasonic transducer is increased to improve the quality of ultrasound images, heat is generated inside the transducer, which can burn the patient’s skin and degrade transducer performance. In this study, the method to disperse the heat inside an ultrasonic phased-array transducer has been examined. The mechanism of temperature rise due to heat generation inside the transducer was investigated by numerical analysis and the effects of the thermal properties of the components of the transducer such as specific heat and thermal conductivity on the temperature rise were analyzed. On the basis of the results, a heat-dispersive structure was devised to reduce the temperature at the surface of the acoustic lens of the transducer. Prototype transducers were fabricated to check the efficacy of the heat-dispersive structure. By experiments, we have confirmed that the new heat-dispersive structure can reduce the internal temperature by as much as 50% in comparison with the conventional structure, which confirms the validity of the thermal dispersion mechanism developed in this work.

  1. 40 CFR 1066.240 - Torque transducer verification and calibration.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification and calibration. Calibrate torque-measurement systems as described in 40 CFR 1065.310. ... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Torque transducer verification...

  2. 40 CFR 1066.240 - Torque transducer verification.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Torque transducer verification. 1066... POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification. Verify torque-measurement systems by performing the verifications described in §§ 1066.270...

  3. 40 CFR 1066.240 - Torque transducer verification and calibration.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) AIR POLLUTION CONTROLS VEHICLE-TESTING PROCEDURES Dynamometer Specifications § 1066.240 Torque transducer verification and calibration. Calibrate torque-measurement systems as described in 40 CFR 1065.310. ... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Torque transducer verification...

  4. Metal cap flexural transducers for air-coupled ultrasonics

    NASA Astrophysics Data System (ADS)

    Eriksson, T. J. R.; Dixon, S.; Ramadas, S. N.

    2015-03-01

    Ultrasonic generation and detection in fluids is inefficient due to the large difference in acoustic impedance between the piezoelectric element and the propagation medium, leading to large internal reflections and energy loss. One way of addressing the problem is to use a flexural transducer, which uses the bending modes in a thin plate or membrane. As the plate bends, it displaces the medium in front of it, hence producing sound waves. A piezoelectric flexural transducer can generate large amplitude displacements in fluid media for relatively low excitation voltages. Commercially available flexural transducers for air applications operate at 40 kHz, but there exists ultrasound applications that require significantly higher frequencies, e.g. flow measurements. Relatively little work has been done to date to understand the underlying physics of the flexural transducer, and hence how to design it to have specific properties suitable for particular applications. This paper investigates the potential of the flexural transducer and its operating principles. Two types of actuation methods are considerd: piezoelectric and electrodynamic. The piezoelectrically actuated transducer is more energy efficient and intrinsically safe, but the electrodynamic transducer has the advantage of being less sensitive to high temperature environments. The theory of vibrating plates is used to predict transducer frequency in addition to front face amplitude, which shows good correlation with experimental results.

  5. Microbial production of 1,3-propanediol.

    PubMed

    Sauer, Michael; Marx, Hans; Mattanovich, Diethard

    2008-01-01

    The introduction of economic production processes for 1,3-propanediol is a success story for the creation of a new market for a (bulk) chemical. The compound and its favorable properties have long been known; also the fermentation of glycerol to 1,3-propanediol had been described more than 120 years ago. Nevertheless, the product remained a specialty chemical until recently, when two new processes were introduced, providing 1,3-propanediol at a competitive price. Remarkably, one of the processes is in the field of white biotechnology and based on microbial fermentation, converting a renewable carbon source into a bulk chemical. This review covers the most important patents that led to the commercialization of bio-based 1,3-propanediol. Furthermore, some of the recent developments towards a sustainable industry are addressed. Similar questions arise for a variety of products if they are to be produced bio-based in large scale. However, special emphasis is given to 1,3-propanediol production. PMID:19075867

  6. NDE of interfaces in the tube geometry with piezofilm transducers

    SciTech Connect

    Hsu, D.K.; Zhang, Zhong.

    1991-01-01

    The flexible polymer piezofilms such as polyvinylidene fluoride (1) (PVDF) posses distinct advantages as ultrasonic transducers for inspecting cylindrically symmetric components, including rods, pipes, cladding, and tube interfaces. The flexibility and contour conforming nature of the film transducer ensure normal incidence and avoid mode conversion. In this work, PVDF transducers are used in the evaluation of interfaces in coaxially extruded Zirconium-Zircaloy tubes and the clamping condition of Nitinol couplers over stainless steel tubing. Detailed description will be given for the evaluation of an interface in a Zirconium-Zircaloy tube, on which the same transducer was used both as the transmitter and the receiver. The multiple echo signals were analyzed and reflection coefficient as small as 0.006 was accurately measured. Comparison will be made with the measurement results of conventional transducers. 5 refs., 6 figs.

  7. NDE of interfaces in the tube geometry with piezofilm transducers

    SciTech Connect

    Hsu, D.K.; Zhang, Zhong

    1991-12-31

    The flexible polymer piezofilms such as polyvinylidene fluoride [1] (PVDF) posses distinct advantages as ultrasonic transducers for inspecting cylindrically symmetric components, including rods, pipes, cladding, and tube interfaces. The flexibility and contour conforming nature of the film transducer ensure normal incidence and avoid mode conversion. In this work, PVDF transducers are used in the evaluation of interfaces in coaxially extruded Zirconium-Zircaloy tubes and the clamping condition of Nitinol couplers over stainless steel tubing. Detailed description will be given for the evaluation of an interface in a Zirconium-Zircaloy tube, on which the same transducer was used both as the transmitter and the receiver. The multiple echo signals were analyzed and reflection coefficient as small as 0.006 was accurately measured. Comparison will be made with the measurement results of conventional transducers. 5 refs., 6 figs.

  8. Frequency response calibration of recess-mounted pressure transducers

    NASA Technical Reports Server (NTRS)

    Marcolini, M. A.; Lorber, P. F.; Miller, W. T., Jr.; Covino, A. F., Jr.

    1991-01-01

    A technique is described for measuring the frequency response of pressure transducers mounted inside a model, where a narrow pipette leads to an orifice at the surface. An acoustic driver is mounted to a small chamber which has an opening at the opposite end with an O-ring seal to place over the orifice. A 3.18 mm (1/8 inch) reference microphone is mounted to one side of the chamber. The acoustic driver receives an input of white noise, and the transducer and reference microphone outputs are compared to obtain the frequency response of the pressure transducer. Selected results are presented in the form of power spectra for both the transducer and the reference, as well as the amplitude variation and phase shift between the two signals as a function of frequency. The effect of pipette length and the use of this technique for identifying both blocked orifices and faulty transducers are described.

  9. Design of matching layers for high-frequency ultrasonic transducers

    NASA Astrophysics Data System (ADS)

    Fei, Chunlong; Ma, Jianguo; Chiu, Chi Tat; Williams, Jay A.; Fong, Wayne; Chen, Zeyu; Zhu, BenPeng; Xiong, Rui; Shi, Jing; Hsiai, Tzung K.; Shung, K. Kirk; Zhou, Qifa

    2015-09-01

    Matching the acoustic impedance of high-frequency (≥100 MHz) ultrasound transducers to an aqueous loading medium remains a challenge for fabricating high-frequency transducers. The traditional matching layer design has been problematic to establish high matching performance given requirements on both specific acoustic impedance and precise thickness. Based on both mass-spring scheme and microwave matching network analysis, we interfaced metal-polymer layers for the matching effects. Both methods hold promises for guiding the metal-polymer matching layer design. A 100 MHz LiNbO3 transducer was fabricated to validate the performance of the both matching layer designs. In the pulse-echo experiment, the transducer echo amplitude increased by 84.4% and its -6dB bandwidth increased from 30.2% to 58.3% comparing to the non-matched condition, demonstrating that the matching layer design method is effective for developing high-frequency ultrasonic transducers.

  10. Piezoelectric single crystals for ultrasonic transducers in biomedical applications.

    PubMed

    Zhou, Qifa; Lam, Kwok Ho; Zheng, Hairong; Qiu, Weibao; Shung, K Kirk

    2014-10-01

    Piezoelectric single crystals, which have excellent piezoelectric properties, have extensively been employed for various sensors and actuators applications. In this paper, the state-of-art in piezoelectric single crystals for ultrasonic transducer applications is reviewed. Firstly, the basic principles and design considerations of piezoelectric ultrasonic transducers will be addressed. Then, the popular piezoelectric single crystals used for ultrasonic transducer applications, including LiNbO3 (LN), PMN-PT and PIN-PMN-PT, will be introduced. After describing the preparation and performance of the single crystals, the recent development of both the single-element and array transducers fabricated using the single crystals will be presented. Finally, various biomedical applications including eye imaging, intravascular imaging, blood flow measurement, photoacoustic imaging, and microbeam applications of the single crystal transducers will be discussed. PMID:25386032

  11. Piezoelectric single crystals for ultrasonic transducers in biomedical applications

    PubMed Central

    Zhou, Qifa; Lam, Kwok Ho; Zheng, Hairong; Qiu, Weibao; Shung, K. Kirk

    2014-01-01

    Piezoelectric single crystals, which have excellent piezoelectric properties, have extensively been employed for various sensors and actuators applications. In this paper, the state–of–art in piezoelectric single crystals for ultrasonic transducer applications is reviewed. Firstly, the basic principles and design considerations of piezoelectric ultrasonic transducers will be addressed. Then, the popular piezoelectric single crystals used for ultrasonic transducer applications, including LiNbO3 (LN), PMN–PT and PIN–PMN–PT, will be introduced. After describing the preparation and performance of the single crystals, the recent development of both the single–element and array transducers fabricated using the single crystals will be presented. Finally, various biomedical applications including eye imaging, intravascular imaging, blood flow measurement, photoacoustic imaging, and microbeam applications of the single crystal transducers will be discussed. PMID:25386032

  12. Durability investigation of a group of strain gage pressure transducers

    NASA Technical Reports Server (NTRS)

    Lederer, P. S.; Hilten, J. S.

    1972-01-01

    A durability investigation was conducted on a group of eighteen bonded-wire strain gage pressure transducers with ranges of 0 to 15 psig and 0 to 100 psig using an improved version of a previously developed technique. Some of the transducers were subjected to 40 million pressure cycles at a 5-Hz rate at laboratory ambient conditions, others were cycled at a temperature of 150 F (65.6 C). The largest change in sensitivity observed was 0.22% for a 100-psig transducer subjected to 40 million pressure cycles at 150 F. The largest change in zero pressure output observed was 0.91% FS for the same transducer. None of the transducers failed completely as a result of cycling at or below full scale pressure.

  13. Embedded Ultrasonic Transducers for Active and Passive Concrete Monitoring

    PubMed Central

    Niederleithinger, Ernst; Wolf, Julia; Mielentz, Frank; Wiggenhauser, Herbert; Pirskawetz, Stephan

    2015-01-01

    Recently developed new transducers for ultrasonic transmission, which can be embedded right into concrete, are now used for non-destructive permanent monitoring of concrete. They can be installed during construction or thereafter. Large volumes of concrete can be monitored for changes of material properties by a limited number of transducers. The transducer design, the main properties as well as installation procedures are presented. It is shown that compressional waves with a central frequency of 62 kHz are mainly generated around the transducer’s axis. The transducer can be used as a transmitter or receiver. Application examples demonstrate that the transducers can be used to monitor concrete conditions parameters (stress, temperature, …) as well as damages in an early state or the detection of acoustic events (e.g., crack opening). Besides application in civil engineering our setups can also be used for model studies in geosciences. PMID:25923928

  14. Carcinogenicity of 1,3-butadiene.

    PubMed Central

    Melnick, R L; Shackelford, C C; Huff, J

    1993-01-01

    1,3-Butadiene, a high-production volume chemical used largely in the manufacture of synthetic rubber, is a multiple organ carcinogen in rats and mice. In inhalation studies conducted in mice by the National Toxicology Program, high rates of early lethal lymphomas occurring at exposure levels of 625 ppm or higher reduced the development and expression of later developing tumors at other sites. Use of survival-adjusted tumor rates to account for competing risk factors provided a clearer indication of the dose responses for 1,3-butadiene-induced neoplasms. An increase in lung tumors in female mice was observed at exposure concentrations as low as 6.25 ppm, the lowest concentration ever used in a long-term carcinogenicity study of this gas. Human exposures to 1,3-butadiene by workers employed at facilities that produce this chemical and at facilities that produce styrene-butadiene rubber have been measured at levels higher than those that cause cancer in animals. Furthermore, epidemiology studies have consistently revealed associations between occupational exposure to 1,3-butadiene and excess mortality due to lymphatic and hematopoietic cancers. In response to the carcinogenicity findings for 1,3-butadiene in animals and in humans, the Occupational Safety and Health Administration has proposed lowering the occupational exposure standard for this chemical from 1000 ppm to 2 ppm. Future work is needed to understand the mechanisms of tumor induction by 1,3-butadiene; however, the pursuit of this research should not delay the reduction of human exposure to this chemical. PMID:8354171

  15. Electronic Learning Centers. Grades 1-3.

    ERIC Educational Resources Information Center

    North Carolina State Dept. of Public Instruction, Raleigh. Media and Technology Services.

    This book contains directions for creating learning centers for use in grades 1-3 which use both computer and traditional activities. Information on each center includes goals and objectives, a time requirement, and specific guidelines for management of the activity. Required materials, including software, are indicated, and masters to duplicate…

  16. A Dogrib History. Grade 1-3.

    ERIC Educational Resources Information Center

    Fraser, Tara

    A publication on the history and traditional lifestyle of the Dogrib Tribe of Canada's Northwest Territories is intended for use in grades 1-3. Text is printed in large, clear letters and accompanied by many drawings. Some subjects covered are cooking, food, canoes, clothes, homes, and games. Sections are devoted to beavers and caribou and their…

  17. TRANSDUCER GENERATED ARRAYS OF ROBOTIC NANO-ARMS.

    PubMed

    Dolzhenko, Egor; Jonoska, Nataša; Seeman, Nadrian C

    2010-06-01

    We consider sets of two-dimensional arrays, called here transducer generated languages, obtained by iterative applications of transducers (finite state automata with output). Each transducer generates a set of blocks of symbols such that the bottom row of a block is an input string accepted by the transducer and, by iterative application of the transducer, each row of the block is an output of the transducer on the preceding row. We show how these arrays can be implemented through molecular assembly of triple crossover DNA molecules. Such assembly could serve as a scaffold for arranging molecular robotic arms capable for simultaneous movements. We observe that transducer generated languages define a class of languages which is a proper subclass of recognizable picture languages, but it containing the class of all factorial local two-dimensional languages. By taking the average growth rate of the number of blocks in the language as a measure of its complexity, we further observe that arrays with high complexity patterns can be generated in this way. PMID:24653669

  18. Long term performance of wearable transducer for motion energy harvesting

    NASA Astrophysics Data System (ADS)

    McGarry, Scott A.; Behrens, Sam

    2010-04-01

    Personal electronic devices such as cell phones, GPS and MP3 players have traditionally depended on battery energy storage technologies for operation. By harvesting energy from a person's motion, these devices may achieve greater run times without increasing the mass or volume of the electronic device. Through the use of a flexible piezoelectric transducer such as poly-vinylidene fluoride (PVDF), and integrating it into a person's clothing, it becomes a 'wearable transducer'. As the PVDF transducer is strained during the person's routine activities, it produces an electrical charge which can then be harvested to power personal electronic devices. Existing wearable transducers have shown great promise for personal motion energy harvesting applications. However, they are presently physically bulky and not ergonomic for the wearer. In addition, there is limited information on the energy harvesting performance for wearable transducers, especially under realistic conditions and for extended cyclic force operations - as would be experienced when worn. In this paper, we present experimental results for a wearable PVDF transducer using a person's measured walking force profile, which is then cycled for a prolonged period of time using an experimental apparatus. Experimental results indicate that after an initial drop in performance, the transducer energy harvesting performance does not substantially deteriorate over time, as less than 10% degradation was observed. Longevity testing is still continuing at CSIRO.

  19. Design of advanced ultrasonic transducers for welding devices.

    PubMed

    Parrini, L

    2001-11-01

    A new high frequency ultrasonic transducer has been conceived, designed, prototyped, and tested. In the design phase, an advanced approach was used and established. The method is based on an initial design estimate obtained with finite element method (FEM) simulations. The simulated ultrasonic transducers and resonators are then built and characterized experimentally through laser interferometry and electrical resonance spectra. The comparison of simulation results with experimental data allows the parameters of FEM models to be adjusted and optimized. The achieved FEM simulations exhibit a remarkably high predictive potential and allow full control of the vibration behavior of the transducer. The new transducer is mounted on a wire bonder with a flange whose special geometry was calculated by means of FEM simulations. This flange allows the transducer to be attached on the wire bonder, not only in longitudinal nodes, but also in radial nodes of the ultrasonic field excited in the horn. This leads to a total decoupling of the transducer to the wire bonder, which has not been achieved so far. The new approach to mount ultrasonic transducers on a welding device is of major importance, not only for wire bonding, but also for all high power ultrasound applications and has been patented. PMID:11800125

  20. Dual-frequency transducer for nonlinear contrast agent imaging.

    PubMed

    Guiroy, Axel; Novell, Anthony; Ringgaard, Erling; Lou-Moeller, Rasmus; Grégoire, Jean-Marc; Abellard, André-Pierre; Zawada, Tomasz; Bouakaz, Ayache; Levassort, Franck

    2013-12-01

    Detection of high-order nonlinear components issued from microbubbles has emerged as a sensitive method for contrast agent imaging. Nevertheless, the detection of these high-frequency components, including the third, fourth, and fifth harmonics, remains challenging because of the lack of transducer sensitivity and bandwidth. In this context, we propose a new design of imaging transducer based on a simple fabrication process for high-frequency nonlinear imaging. The transducer is composed of two elements: the outer low-frequency (LF) element was centered at 4 MHz and used in transmit mode, whereas the inner high-frequency (HF) element centered at 14 MHz was used in receive mode. The center element was pad-printed using a lead zirconate titanate (PZT) paste. The outer element was molded using a commercial PZT, and curved porous unpoled PZT was used as backing. Each piezoelectric element was characterized to determine the electromechanical performance with thickness coupling factor around 45%. After the assembly of the two transducer elements, hydrophone measurements (electroacoustic responses and radiation patterns) were carried out and demonstrated a large bandwidth (70% at -3 dB) of the HF transducer. Finally, the transducer was evaluated for contrast agent imaging using contrast agent microbubbles. The results showed that harmonic components (up to the sixth harmonic) of the microbubbles were successfully detected. Moreover, images from a flow phantom were acquired and demonstrated the potential of the transducer for high-frequency nonlinear contrast imaging. PMID:24297028