Science.gov

Sample records for 1-mm spatial resolution

  1. High-resolution medical imaging system for 3D imaging of radioactive sources with 1-mm FWHM spatial resolution

    NASA Astrophysics Data System (ADS)

    Smither, Robert K.

    2003-06-01

    This paper describes a modification of a new imaging system developed at Argonne National Laboratory that has the potential of achieving a spatial resolution of 1 mm FWHM. The imaging system uses a crystal diffraction lens to focus gamma rays from the radioactive source. The medical imaging application of this system would be to detect small amounts of radioactivity in the human body that would be associated with cancer. The best spatial resolution obtained with the present lens at the time of the presentation made at the Medical Imaging Symposium 2001, was 6.7 mm FWHM for a 1-mm-diameter source. Since then it has been possible to improve the spacial resolution of the lens system to 3 mm FWHM. Experiments with the original lens system have led to a new design for a lens system that could have a spacial resolution of 1 mm FWHM. This is accomplished by: one, reducing the radial dimension of the crystals, and two, by replacing the small individual crystals with bent strips of single-crystalline material. Experiments are under way to test this approach.

  2. Integrated intravascular ultrasound and optical-resolution photoacoustic microscopy with a 1-mm-diameter catheter

    NASA Astrophysics Data System (ADS)

    Bai, Xiaosong; Gong, Xiaojing; Lin, Riqiang; Hau, William; Song, Liang

    2014-03-01

    Intravascular ultrasound (IVUS) plays a vital role in assessing the severity of atherosclerosis and has greatly enriched our knowledge on atherosclerotic plaques. However, it mainly reveals the structural information of plaques. In contrast, spectroscopic and molecular photoacoustic imaging can potentially improve plaque composition identification, inflammation detection, and ultimately the stratification of plaque vulnerability and risk. In this work, we developed an integrated intravascular ultrasound and optical-resolution photoacoustic microscopy (IVUS-PAM) system with a single catheter as small as 1 mm in diameter, comparable to that of existing clinical IVUS catheters. In addition, by using a GRIN lens to focus the excitation laser pulse, the system provides an optical-diffraction limited photoacoustic lateral resolution as fine as 19.6 micrometers, ~10-fold finer than that of conventional intravascular photoacoustic imaging and existing IVUS technology. The system employs a custom-made miniaturized single-element ultrasonic transducer with a dimension of ~0.5 mm, a centre frequency of ~40 MHz, and a fractional bandwidth of ~60%. The IVUS-PAM can simultaneously acquire co-registered IVUS images with an axial resolution of ~40 micrometers and a lateral resolution of ~200 micrometers. In the future, IVUS-PAM may open up new opportunities for improved high-resolution vulnerable plaque imaging and image-guided stent deployment.

  3. Intravascular Optical-Resolution Photoacoustic Tomography with a 1.1 mm Diameter Catheter

    PubMed Central

    Bai, Xiaosong; Gong, Xiaojing; Hau, William; Lin, Riqiang; Zheng, Jiaxiang; Liu, Chengbo; Zeng, Chengzhi; Zou, Xin; Zheng, Hairong; Song, Liang

    2014-01-01

    Photoacoustic imaging is an emerging technology that can provide anatomic, functional, and molecular information about biological tissue. Intravascular spectroscopic and molecular photoacoustic imaging can potentially improve the identification of atherosclerotic plaque composition, the detection of inflammation, and ultimately the risk stratification of atherosclerosis. In this study, a first-of-its-kind intravascular optical-resolution photoacoustic tomography (OR-PAT) system with a 1.1 mm diameter catheter is developed, offering optical-diffraction limited transverse resolution as fine as 19.6 μm, ∼10-fold finer than that of conventional intravascular photoacoustic and ultrasonic imaging. To offer complementary imaging information and depth, the system also acquires co-registered intravascular ultrasound images in parallel. Imaging of an iliac stent and a lipid phantom shows that the high resolution and contrast of OR-PAT can enable improved stent implantation guidance and lipid identification. In the future, these capabilities may ultimately improve the diagnosis and interventional treatment of vulnerable atherosclerotic plaques, which are prone to cause thrombotic complications such as myocardial infarction and stroke. PMID:24651256

  4. Thermal regulation of tightly packed solid-state photodetectors in a 1 mm{sup 3} resolution clinical PET system

    SciTech Connect

    Freese, D. L.; Vandenbroucke, A.; Innes, D.; Lau, F. W. Y.; Hsu, D. F. C.; Reynolds, P. D.; Levin, Craig S.

    2015-01-15

    Purpose: Silicon photodetectors are of significant interest for use in positron emission tomography (PET) systems due to their compact size, insensitivity to magnetic fields, and high quantum efficiency. However, one of their main disadvantages is fluctuations in temperature cause strong shifts in gain of the devices. PET system designs with high photodetector density suffer both increased thermal density and constrained options for thermally regulating the devices. This paper proposes a method of thermally regulating densely packed silicon photodetectors in the context of a 1 mm{sup 3} resolution, high-sensitivity PET camera dedicated to breast imaging. Methods: The PET camera under construction consists of 2304 units, each containing two 8 × 8 arrays of 1 mm{sup 3} LYSO crystals coupled to two position sensitive avalanche photodiodes (PSAPD). A subsection of the proposed camera with 512 PSAPDs has been constructed. The proposed thermal regulation design uses water-cooled heat sinks, thermoelectric elements, and thermistors to measure and regulate the temperature of the PSAPDs in a novel manner. Active cooling elements, placed at the edge of the detector stack due to limited access, are controlled based on collective leakage current and temperature measurements in order to keep all the PSAPDs at a consistent temperature. This thermal regulation design is characterized for the temperature profile across the camera and for the time required for cooling changes to propagate across the camera. These properties guide the implementation of a software-based, cascaded proportional-integral-derivative control loop that controls the current through the Peltier elements by monitoring thermistor temperature and leakage current. The stability of leakage current, temperature within the system using this control loop is tested over a period of 14 h. The energy resolution is then measured over a period of 8.66 h. Finally, the consistency of PSAPD gain between independent

  5. Effects of spatial resolution

    NASA Technical Reports Server (NTRS)

    Abrams, M.

    1982-01-01

    Studies of the effects of spatial resolution on extraction of geologic information are woefully lacking but spatial resolution effects can be examined as they influence two general categories: detection of spatial features per se; and the effects of IFOV on the definition of spectral signatures and on general mapping abilities.

  6. Particle detector spatial resolution

    DOEpatents

    Perez-Mendez, Victor

    1992-01-01

    Method and apparatus for producing separated columns of scintillation layer material, for use in detection of X-rays and high energy charged particles with improved spatial resolution. A pattern of ridges or projections is formed on one surface of a substrate layer or in a thin polyimide layer, and the scintillation layer is grown at controlled temperature and growth rate on the ridge-containing material. The scintillation material preferentially forms cylinders or columns, separated by gaps conforming to the pattern of ridges, and these columns direct most of the light produced in the scintillation layer along individual columns for subsequent detection in a photodiode layer. The gaps may be filled with a light-absorbing material to further enhance the spatial resolution of the particle detector.

  7. Particle detector spatial resolution

    DOEpatents

    Perez-Mendez, V.

    1992-12-15

    Method and apparatus for producing separated columns of scintillation layer material, for use in detection of X-rays and high energy charged particles with improved spatial resolution is disclosed. A pattern of ridges or projections is formed on one surface of a substrate layer or in a thin polyimide layer, and the scintillation layer is grown at controlled temperature and growth rate on the ridge-containing material. The scintillation material preferentially forms cylinders or columns, separated by gaps conforming to the pattern of ridges, and these columns direct most of the light produced in the scintillation layer along individual columns for subsequent detection in a photodiode layer. The gaps may be filled with a light-absorbing material to further enhance the spatial resolution of the particle detector. 12 figs.

  8. High-resolution 1050 nm spectral domain retinal optical coherence tomography at 120 kHz A-scan rate with 6.1 mm imaging depth

    PubMed Central

    An, Lin; Li, Peng; Lan, Gongpu; Malchow, Doug; Wang, Ruikang K.

    2013-01-01

    We report a newly developed high speed 1050nm spectral domain optical coherence tomography (SD-OCT) system for imaging posterior segment of human eye. The system is capable of an axial resolution at ~10 µm in air, an imaging depth of 6.1 mm in air, a system sensitivity fall-off at ~6 dB/3mm and an imaging speed of 120,000 A-scans per second. We experimentally demonstrate the system’s capability to perform phase-resolved imaging of dynamic blood flow within retina, indicating high phase stability of the SDOCT system. Finally, we show an example that uses this newly developed system to image posterior segment of human eye with a large view of view (10 × 9 mm2), providing detailed visualization of microstructural features from anterior retina to posterior choroid. The demonstrated system parameters and imaging performances are comparable to those that a typical 1 µm swept source OCT would deliver for retinal imaging. PMID:23411636

  9. Spatial resolution in visual memory.

    PubMed

    Ben-Shalom, Asaf; Ganel, Tzvi

    2015-04-01

    Representations in visual short-term memory are considered to contain relatively elaborated information on object structure. Conversely, representations in earlier stages of the visual hierarchy are thought to be dominated by a sensory-based, feed-forward buildup of information. In four experiments, we compared the spatial resolution of different object properties between two points in time along the processing hierarchy in visual short-term memory. Subjects were asked either to estimate the distance between objects or to estimate the size of one of the objects' features under two experimental conditions, of either a short or a long delay period between the presentation of the target stimulus and the probe. When different objects were referred to, similar spatial resolution was found for the two delay periods, suggesting that initial processing stages are sensitive to object-based properties. Conversely, superior resolution was found for the short, as compared with the long, delay when features were referred to. These findings suggest that initial representations in visual memory are hybrid in that they allow fine-grained resolution for object features alongside normal visual sensitivity to the segregation between objects. The findings are also discussed in reference to the distinction made in earlier studies between visual short-term memory and iconic memory.

  10. Spatial resolution in vector potential photoelectron microscopy

    SciTech Connect

    Browning, R.

    2014-03-15

    The experimental spatial resolution of vector potential photoelectron microscopy is found to be much higher than expected because of the cancellation of one of the expected contributions to the point spread function. We present a new calculation of the spatial resolution with support from finite element ray tracing, and experimental results.

  11. High-spatial-resolution nanoparticle x-ray fluorescence tomography

    NASA Astrophysics Data System (ADS)

    Larsson, Jakob C.; Vâgberg, William; Vogt, Carmen; Lundström, Ulf; Larsson, Daniel H.; Hertz, Hans M.

    2016-03-01

    X-ray fluorescence tomography (XFCT) has potential for high-resolution 3D molecular x-ray bio-imaging. In this technique the fluorescence signal from targeted nanoparticles (NPs) is measured, providing information about the spatial distribution and concentration of the NPs inside the object. However, present laboratory XFCT systems typically have limited spatial resolution (>1 mm) and suffer from long scan times and high radiation dose even at high NP concentrations, mainly due to low efficiency and poor signal-to-noise ratio. We have developed a laboratory XFCT system with high spatial resolution (sub-100 μm), low NP concentration and vastly decreased scan times and dose, opening up the possibilities for in-vivo small-animal imaging research. The system consists of a high-brightness liquid-metal-jet microfocus x-ray source, x-ray focusing optics and an energy-resolving photon-counting detector. By using the source's characteristic 24 keV line-emission together with carefully matched molybdenum nanoparticles the Compton background is greatly reduced, increasing the SNR. Each measurement provides information about the spatial distribution and concentration of the Mo nanoparticles. A filtered back-projection method is used to produce the final XFCT image.

  12. SPATIAL AND SPECTRAL RESOLUTION IN GEOBOTANY.

    USGS Publications Warehouse

    Milton, Nancy M.; Mouat, D.A.

    1984-01-01

    Remotely sensed data are now available from a wide variety of instruments, each data set having a particular spectral and spatial resolution. The changes in vegetation associated with changes in lithology or the presence of mineral deposits can also occur at different scales. The task of geobotanical remote sensing is to choose or adapt the remotely sensed data to the appropriate geobotanical technique to solve the geological problem of interest. Examples are given of a number of applications of data sets of different spectral and spatial resolution. The relative importance of spectral and spatial resolution is discussed.

  13. Fundamental Limits of Spatial Resolution in PET

    PubMed Central

    Moses, William W.

    2010-01-01

    The fundamental limits of spatial resolution in positron emission tomography (PET) have been understood for many years. The physical size of the detector element usually plays the dominant role in determining resolution, but the combined contributions from acollinearity, positron range, penetration into the detector ring, and decoding errors in the detector modules often combine to be of similar size. In addition, the sampling geometry and statistical noise further degrade the effective resolution. This paper describes quantitatively describes these effects, discusses potential methods for reducing the magnitude of these effects, and computes the ultimately achievable spatial resolution for clinical and pre-clinical PET cameras. PMID:21804677

  14. The spatial resolution of epidemic peaks.

    PubMed

    Mills, Harriet L; Riley, Steven

    2014-04-01

    The emergence of novel respiratory pathogens can challenge the capacity of key health care resources, such as intensive care units, that are constrained to serve only specific geographical populations. An ability to predict the magnitude and timing of peak incidence at the scale of a single large population would help to accurately assess the value of interventions designed to reduce that peak. However, current disease-dynamic theory does not provide a clear understanding of the relationship between: epidemic trajectories at the scale of interest (e.g. city); population mobility; and higher resolution spatial effects (e.g. transmission within small neighbourhoods). Here, we used a spatially-explicit stochastic meta-population model of arbitrary spatial resolution to determine the effect of resolution on model-derived epidemic trajectories. We simulated an influenza-like pathogen spreading across theoretical and actual population densities and varied our assumptions about mobility using Latin-Hypercube sampling. Even though, by design, cumulative attack rates were the same for all resolutions and mobilities, peak incidences were different. Clear thresholds existed for all tested populations, such that models with resolutions lower than the threshold substantially overestimated population-wide peak incidence. The effect of resolution was most important in populations which were of lower density and lower mobility. With the expectation of accurate spatial incidence datasets in the near future, our objective was to provide a framework for how to use these data correctly in a spatial meta-population model. Our results suggest that there is a fundamental spatial resolution for any pathogen-population pair. If underlying interactions between pathogens and spatially heterogeneous populations are represented at this resolution or higher, accurate predictions of peak incidence for city-scale epidemics are feasible. PMID:24722420

  15. High Spatial Resolution Thermal Satellite Technologies

    NASA Technical Reports Server (NTRS)

    Ryan, Robert

    2003-01-01

    This document in the form of viewslides, reviews various low-cost alternatives to high spatial resolution thermal satellite technologies. There exists no follow-on to Landsat 7 or ASTER high spatial resolution thermal systems. This document reviews the results of the investigation in to the use of new technologies to create a low-cost useful alternative. Three suggested technologies are examined. 1. Conventional microbolometer pushbroom modes offers potential for low cost Landsat Data Continuity Mission (LDCM) thermal or ASTER capability with at least 60-120 ground sampling distance (GSD). 2. Backscanning could produce MultiSpectral Thermal Imager performance without cooled detectors. 3. Cooled detector could produce hyperspectral thermal class system or extremely high spatial resolution class instrument.

  16. Identifying Optimal Spatial Resolutions For Trend Detection

    NASA Astrophysics Data System (ADS)

    Barnett, W.; Duffy, P.

    2014-12-01

    One of the key challenges facing the ecological community lies in understanding the impacts of forecast climate change on the structure and function of ecosystems both through time and across large spatial extents. There are two main obstacles that currently hinder the ability to quantify ecosystem change in this manner within the context of a shifting climate. First, with respect to key ecosystem responses, there are limited data that have sufficient spatial-temporal resolution and extent. Second, methods for quantifying long term changes in ecosystem responses with complex spatial and temporal structure driven by climatic forcing are not well developed. In this work we focus on the question "What is the most appropriate spatial resolution for detecting a process level trend?" We address this question through the development and application of a simulation framework that allows for the parametric specification of the following model components: measurement error, the functional form of the link between climate drivers and the ecosystem response, and annual process variability dealing with non-separable space-time covariance structures. We consider varying spatial resolution and the corresponding impact of the covariance structure associated with the data model. This is parameterized in the simulation framework through an additive measurement error term. As the spatial resolution becomes coarser, sub-pixel heterogeneity becomes absorbed by the measurement error term as opposed to attribution to parameters in the process model. The results of this study characterize an "envelope" of values for these parameters that allow for the detection of trend in process model parameter. This study outlines a quantitative method of choosing a spatial resolution that allows for the detection of trend given a collection of prior distributions associated with other model parameters.

  17. Spatial resolution limits for the isotropic-3D PET detector X’tal cube

    NASA Astrophysics Data System (ADS)

    Yoshida, Eiji; Tashima, Hideaki; Hirano, Yoshiyuki; Inadama, Naoko; Nishikido, Fumihiko; Murayama, Hideo; Yamaya, Taiga

    2013-11-01

    Positron emission tomography (PET) has become a popular imaging method in metabolism, neuroscience, and molecular imaging. For dedicated human brain and small animal PET scanners, high spatial resolution is needed to visualize small objects. To improve the spatial resolution, we are developing the X’tal cube, which is our new PET detector to achieve isotropic 3D positioning detectability. We have shown that the X’tal cube can achieve 1 mm3 uniform crystal identification performance with the Anger-type calculation even at the block edges. We plan to develop the X’tal cube with even smaller 3D grids for sub-millimeter crystal identification. In this work, we investigate spatial resolution of a PET scanner based on the X’tal cube using Monte Carlo simulations for predicting resolution performance in smaller 3D grids. For spatial resolution evaluation, a point source emitting 511 keV photons was simulated by GATE for all physical processes involved in emission and interaction of positrons. We simulated two types of animal PET scanners. The first PET scanner had a detector ring 14.6 cm in diameter composed of 18 detectors. The second PET scanner had a detector ring 7.8 cm in diameter composed of 12 detectors. After the GATE simulations, we converted the interacting 3D position information to digitalized positions for realistic segmented crystals. We simulated several X’tal cubes with cubic crystals from (0.5 mm)3 to (2 mm)3 in size. Also, for evaluating the effect of DOI resolution, we simulated several X’tal cubes with crystal thickness from (0.5 mm)3 to (9 mm)3. We showed that sub-millimeter spatial resolution was possible using cubic crystals smaller than (1.0 mm)3 even with the assumed physical processes. Also, the weighted average spatial resolutions of both PET scanners with (0.5 mm)3 cubic crystals were 0.53 mm (14.6 cm ring diameter) and 0.48 mm (7.8 cm ring diameter). For the 7.8 cm ring diameter, spatial resolution with 0.5×0.5×1.0 mm3 crystals

  18. Polarization imaging with enhanced spatial resolution

    NASA Astrophysics Data System (ADS)

    Peinado, A.; Lizana, A.; Iemmi, C.; Campos, J.

    2015-03-01

    We present the design and the experimental implementation of a new imaging set-up, based on Liquid Crystal technology, able to obtain super-resolved polarimetric images of polarimetric samples when the resolution is detector limited. The proposed set-up is a combination of two modules. One of them is an imaging Stokes polarimeter, based on Ferroelectric Liquid Crystal cells, which is used to analyze the polarization spatial distribution of an incident beam. The other module is used to obtain high resolved intensity images of the sample in an optical system whose resolution is mainly limited by the CCD pixel geometry. It contains a calibrated Parallel Aligned Liquid Crystal on Silicon display employed to introduce controlled linear phases. As a result, a set of different low resolved intensity images with sub-pixel displacements are captured by the CCD. By properly combining these images and after applying a deconvolution process, a super-resolved intensity image of the object is obtained. Finally, the combination of the two different optical modules permits to employ super-resolved images during the polarimetric data reduction calculation, leading to a final polarization image with enhanced spatial resolution. The proposed optical set-up performance is implemented and experimentally validated by providing super-resolved images of an amplitude resolution test and a birefringent resolution test. A significant improvement in the spatial resolution (by a factor of 1.4) of the obtained polarimetric images, in comparison with the images obtained with the regular imaging system, is clearly observed when applying our proposed technique.

  19. Effects of spatial resolution on image registration

    NASA Astrophysics Data System (ADS)

    Zhao, Can; Carass, Aaron; Jog, Amod; Prince, Jerry L.

    2016-03-01

    This paper presents a theoretical analysis of the effect of spatial resolution on image registration. Based on the assumption of additive Gaussian noise on the images, the mean and variance of the distribution of the sum of squared differences (SSD) were estimated. Using these estimates, we evaluate a distance between the SSD distributions of aligned images and non-aligned images. The experimental results show that by matching the resolutions of the moving and fixed images one can get a better image registration result. The results agree with our theoretical analysis of SSD, but also suggest that it may be valid for mutual information as well.

  20. High spatial resolution restoration of IRAS images

    NASA Technical Reports Server (NTRS)

    Grasdalen, Gary L.; Inguva, R.; Dyck, H. Melvin; Canterna, R.; Hackwell, John A.

    1990-01-01

    A general technique to improve the spatial resolution of the IRAS AO data was developed at The Aerospace Corporation using the Maximum Entropy algorithm of Skilling and Gull. The technique has been applied to a variety of fields and several individual AO MACROS. With this general technique, resolutions of 15 arcsec were achieved in 12 and 25 micron images and 30 arcsec in 60 and 100 micron images. Results on galactic plane fields show that both photometric and positional accuracy achieved in the general IRAS survey are also achieved in the reconstructed images.

  1. 1 mm ultrafast superconducting stripline molecule detector

    NASA Astrophysics Data System (ADS)

    Zen, N.; Casaburi, A.; Shiki, S.; Suzuki, K.; Ejrnaes, M.; Cristiano, R.; Ohkubo, M.

    2009-10-01

    Superconducting stripline detectors (SSLDs) are promising for detecting keV molecules at nanosecond response times and with mass-independent detection efficiency. However, a fast response time is incompatible with practical centimeter detector size. A parallel configuration of striplines provides a means to address this problem. Experimental results and simulation for promisingly large 1-mm-square parallel niobium SSLDs show that nanosecond pulses are produced by superconducting-normal transition within only one of the parallel striplines instead of cascade switching of all the parallel striplines. Successful detection of a series of multimers of immunoglobulin G up to 584 kDa supports the mass-independent efficiency for mass spectrometry.

  2. HIGH SPATIAL-RESOLUTION IMAGING OF TE INCLUSIONS IN CZT MATERIAL.

    SciTech Connect

    CAMARDA, G.S.; BOLOTNIKOV, A.E.; CARINI, G.A.; CUI, Y.; KOHMAN, K.T.; LI, L.; JAMES, R.B.

    2006-08-13

    We present new results from our studies of defects in current single-crystal CdZnTe material. Our previous measurements, carried out on thin ({approx}1 mm) and long (>12 mm) CZT detectors, indicated that small (1-20 {micro}m) Te inclusions can significantly degrade the device's energy resolution and detection efficiency. We are conducting detailed studies of the effects of Te inclusions by employing different characterization techniques with better spatial resolution, such as quantitative fluorescence mapping, X-ray micro-diffraction, and TEM. Also, IR microscopy and gamma-mapping with pulse-shape analysis with higher spatial resolution generated more accurate results in the areas surrounding the micro-defects (Te inclusions). Our results reveal how the performance of CdZnTe detectors is influenced by Te inclusions, such as their spatial distribution, concentration, and size. We also discuss a model of charge transport through areas populated with Te inclusions.

  3. High Spatial Resolution Commercial Satellite Imaging Product Characterization

    NASA Technical Reports Server (NTRS)

    Ryan, Robert E.; Pagnutti, Mary; Blonski, Slawomir; Ross, Kenton W.; Stnaley, Thomas

    2005-01-01

    NASA Stennis Space Center's Remote Sensing group has been characterizing privately owned high spatial resolution multispectral imaging systems, such as IKONOS, QuickBird, and OrbView-3. Natural and man made targets were used for spatial resolution, radiometric, and geopositional characterizations. Higher spatial resolution also presents significant adjacency effects for accurate reliable radiometry.

  4. Positron Emission Tomography with improved spatial resolution

    SciTech Connect

    Drukier, A.K.

    1990-04-01

    Applied Research Corporation (ARC) proposed the development of a new class of solid state detectors called Superconducting Granular Detectors (SGD). These new detectors permit considerable improvements in medical imaging, e.g. Positron Emission Tomography (PET). The biggest impact of this technique will be in imaging of the brain. It should permit better clinical diagnosis of such important diseases as Altzheimer's or schizophrenia. More specifically, we will develop an improved PET-imager; a spatial resolution 2 mm may be achievable with SGD. A time-of-flight capability(t {approx} 100 psec) will permit better contrast and facilitate 3D imaging. In the following, we describe the results of the first 9 months of the development.

  5. Spatial resolution effect of light coupling structures

    PubMed Central

    Li, Juntao; Li, Kezheng; Schuster, Christian; Su, Rongbin; Wang, Xuehua; Borges, Ben-Hur V.; Krauss, Thomas F.; Martins, Emiliano R.

    2015-01-01

    The coupling of light between free space and thin film semiconductors is an essential requirement of modern optoelectronic technology. For monochromatic and single mode devices, high performance grating couplers have been developed that are well understood. For broadband and multimode devices, however, more complex structures, here referred to as “coupling surfaces”, are required, which are often difficult to realise technologically. We identify general design rules based on the Fourier properties of the coupling surface and show how they can be used to determine the spatial resolution required for the coupler’s fabrication. To our knowledge, this question has not been previously addressed, but it is important for the understanding of diffractive nanostructures and their technological realisation. We exemplify our insights with solar cells and UV photodetectors, where high-performance nanostructures that can be realised cost-effectively are essential. PMID:26678574

  6. High Spatial Resolution Spectroscopy of Semiconductor Nanostructures

    NASA Astrophysics Data System (ADS)

    Harris, Timothy D.; Gershoni, David; Pfeiffer, Loren N.

    1996-03-01

    Several recent reports employing high spatial resolution have revealed the dominance of exciton localization in the low temperature luminescence of semiconductor quantum structures.^[1-3] Understanding this localization is of critical importance for the reliable studies of low dimensional structures such as quantum wells, quantum wires and quantum dots. We report on low temperature and high spatial resolution photoluminescence and photoluminescence excitation studies of cleaved edge overgrown (CEO) single quantum wires. These samples permit the direct and unambiguous comparison between the optical properties of a (100) oriented quantum well, a (110) oriented quantum well, and the quantum wire which is formed at their intersection. Using low temperature near field optical spectroscopy, and a novel diffraction limited far field apparatus, we determine the carrier diffusion length dependence on pump wavelength and sample temperature in both the 2d systems and the genuinely 1D wire system. We also measure the absorption strength of the 1D system and find it to be a factor of 3 stronger than the absorption of the associated 2D systems.^[2] Using low temperature near field optical spectroscopy, and a novel diffraction limited far field apparatus, we also determine the carrier diffusion length dependence on pump wavelength and sample temperature. ^[1] H. F. Hess, E. Betzig, T. D. Harris, L. N. Pfeiffer, and K. W. West, Science 264, 1740 (1994). ^[2] T. D. Harris, D. Gershoni, R. D. Grober, L. Pfeiffer, K. West, and N. Chand, Appl. Phys. Lett, in press (1996) ^[3] D. Gammon, E. S. Snow, and D. S. Katzer, Appl. Phys. Lett. 67, 2391 (1995)

  7. Effects of spatial resolution ratio in image fusion

    USGS Publications Warehouse

    Ling, Y.; Ehlers, M.; Usery, E.L.; Madden, M.

    2008-01-01

    In image fusion, the spatial resolution ratio can be defined as the ratio between the spatial resolution of the high-resolution panchromatic image and that of the low-resolution multispectral image. This paper attempts to assess the effects of the spatial resolution ratio of the input images on the quality of the fused image. Experimental results indicate that a spatial resolution ratio of 1:10 or higher is desired for optimal multisensor image fusion provided the input panchromatic image is not downsampled to a coarser resolution. Due to the synthetic pixels generated from resampling, the quality of the fused image decreases as the spatial resolution ratio decreases (e.g. from 1:10 to 1:30). However, even with a spatial resolution ratio as small as 1:30, the quality of the fused image is still better than the original multispectral image alone for feature interpretation. In cases where the spatial resolution ratio is too small (e.g. 1:30), to obtain better spectral integrity of the fused image, one may downsample the input high-resolution panchromatic image to a slightly lower resolution before fusing it with the multispectral image.

  8. Enhanced spatial resolution on figures versus grounds.

    PubMed

    Hecht, Lauren N; Cosman, Joshua D; Vecera, Shaun P

    2016-07-01

    Much is known about the cues that determine figure-ground assignment, but less is known about the consequences of figure-ground assignment on later visual processing. Previous work has demonstrated that regions assigned figural status are subjectively more shape-like and salient than background regions. The increase in subjective salience of figural regions could be caused by a number of processes, one of which may be enhanced perceptual processing (e.g., an enhanced neural representation) of figures relative to grounds. We explored this hypothesis by having observers perform a perceptually demanding spatial resolution task in which targets appeared on either figure or ground regions. To rule out a purely attentional account of figural salience, observers discriminated targets on the basis of a region's color (red or green), which was equally likely to define the figure or the ground. The results of our experiments showed that targets appearing on figures were discriminated more accurately than those appearing in ground regions. In addition, targets appearing on figures were discriminated better than those presented in regions considered figurally neutral, but targets appearing within ground regions were discriminated more poorly than those appearing in figurally neutral regions. Taken together, our findings suggest that when two regions share a contour, regions assigned as figure are perceptually enhanced, whereas regions assigned as ground are perceptually suppressed. PMID:27048441

  9. Distinguishing and quantification of the human visual pathways using high-spatial-resolution diffusion tensor tractography.

    PubMed

    Kamali, Arash; Hasan, Khader M; Adapa, Pavani; Razmandi, Azadeh; Keser, Zafer; Lincoln, John; Kramer, Larry A

    2014-09-01

    Quantification of the living human visual system using MRI methods has been challenging, but several applications demand a reliable and time-efficient data acquisition protocol. In this study, we demonstrate the utility of high-spatial-resolution diffusion tensor fiber tractography (DTT) in reconstructing and quantifying the human visual pathways. Five healthy males, age range 24-37years, were studied after approval of the institutional review board (IRB) at The University of Texas Health Science Center at Houston. We acquired diffusion tensor imaging (DTI) data with 1-mm slice thickness on a 3.0-Tesla clinical MRI scanner and analyzed the data using DTT with the fiber assignment by continuous tractography (FACT) algorithm. By utilizing the high-spatial-resolution DTI protocol with FACT algorithm, we were able to reconstruct and quantify bilateral optic pathways including the optic chiasm, optic tract, optic radiations free of contamination from neighboring white matter tracts.

  10. Distinguishing and quantification of the human visual pathways using high spatial resolution diffusion tensor tractography

    PubMed Central

    Kamali, Arash; Hasan, Khader M.; Adapa, Pavani; Razmandi, Azadeh; Keser, Zafer; Lincoln, John; Kramer, Larry A.

    2014-01-01

    Quantification of the living human visual system using MRI methods has been challenging, but several applications demand a reliable and time-efficient data acquisition protocol. In this study, we demonstrate the utility of high spatial resolution diffusion tensor fiber tractography (DTT) in reconstructing and quantifying the human visual pathways. Five healthy males, age range 24–37 years, were studied after approval of the Institutional Review Board (IRB) at The University of Texas Health Science Center at Houston. We acquired diffusion tensor imaging (DTI) data with 1-mm slice thickness on a 3.0 Tesla clinical MRI scanner and analyzed the data using DTT with the fiber assignment by continuous tractography (FACT) algorithm. By utilizing the high spatial resolution DTI protocol with FACT algorithm, we were able to reconstruct and quantify bilateral optic pathways including the optic chiasm, optic tract, optic radiations free of contamination from neighboring white matter tracts. PMID:24856625

  11. Improving spatial resolution of confocal Raman microscopy by super-resolution image restoration.

    PubMed

    Cui, Han; Zhao, Weiqian; Wang, Yun; Fan, Ying; Qiu, Lirong; Zhu, Ke

    2016-05-16

    A new super-resolution image restoration confocal Raman microscopy method (SRIR-RAMAN) is proposed for improving the spatial resolution of confocal Raman microscopy. This method can recover the lost high spatial frequency of the confocal Raman microscopy by using Poisson-MAP super-resolution imaging restoration, thereby improving the spatial resolution of confocal Raman microscopy and realizing its super-resolution imaging. Simulation analyses and experimental results indicate that the spatial resolution of SRIR-RAMAN can be improved by 65% to achieve 200 nm with the same confocal Raman microscopy system. This method can provide a new tool for high spatial resolution micro-probe structure detection in physical chemistry, materials science, biomedical science and other areas.

  12. Study of the spatial resolution for binary readout detectors

    NASA Astrophysics Data System (ADS)

    Yonamine, R.; Maerschalk, T.; Lentdecker, G. De

    2016-07-01

    Often the binary readout is proposed for high granularity detectors to reduce the generated data volume to be readout at the price of a somewhat reduced spatial resolution compared to an analogue readout. We have been studying single hit resolutions obtained with a binary readout using simulations as well as analytical approaches. In this note we show that the detector geometry could be optimized to offer an equivalent spatial resolution than with an analogue readout.

  13. Inverse Kriging to Enhance Spatial Resolution of Imagery

    SciTech Connect

    Petrie, Gregg M. ); Heasler, Patrick G. ); Perry, Eileen M. ); Thompson, Sandra E. ); Daly, Don S. )

    2002-12-15

    We describe a unique approach to image resolution enhancement, inverse kriging (IK), which takes advantage of the spatial relationship between high- and low-resolution images within an area of overlap. Once established, this mathematical relationship then can be applied across the entire low-resolution image to significantly sharpen the image. The mathematical relationship uses the spatial correlations within the low-resolution image and between the low and high spatial-resolution imagery. Two of the most important requirements of the technique are that the images be co-registered well within the resolution of the larger pixels and that the spatial structure of the training area (where the spatial correlation statistics are compared) is similar to the structure of the remaining image area where it will be applied. Testing was performed using same-sensor and multi-sensor imagery. We show results that indicate that the method does improve the low spatial-resolution imagery. The selection of a training area spatial structure similar to the area being processed is important, as areas with different spatial structure (e.g., vegetation versus buildings and roads) will produce poor results. Comparisons with bilinear interpolation demonstrate that IK could be used as an improved interpolation tool, for example, in the image-registration process.

  14. Scanning SQUID susceptometers with sub-micron spatial resolution

    NASA Astrophysics Data System (ADS)

    Kirtley, John R.; Paulius, Lisa; Rosenberg, Aaron J.; Palmstrom, Johanna C.; Holland, Connor M.; Spanton, Eric M.; Schiessl, Daniel; Jermain, Colin L.; Gibbons, Jonathan; Fung, Y.-K.-K.; Huber, Martin E.; Ralph, Daniel C.; Ketchen, Mark B.; Gibson, Gerald W.; Moler, Kathryn A.

    2016-09-01

    Superconducting QUantum Interference Device (SQUID) microscopy has excellent magnetic field sensitivity, but suffers from modest spatial resolution when compared with other scanning probes. This spatial resolution is determined by both the size of the field sensitive area and the spacing between this area and the sample surface. In this paper we describe scanning SQUID susceptometers that achieve sub-micron spatial resolution while retaining a white noise floor flux sensitivity of ≈2μΦ0/Hz1/2. This high spatial resolution is accomplished by deep sub-micron feature sizes, well shielded pickup loops fabricated using a planarized process, and a deep etch step that minimizes the spacing between the sample surface and the SQUID pickup loop. We describe the design, modeling, fabrication, and testing of these sensors. Although sub-micron spatial resolution has been achieved previously in scanning SQUID sensors, our sensors not only achieve high spatial resolution but also have integrated modulation coils for flux feedback, integrated field coils for susceptibility measurements, and batch processing. They are therefore a generally applicable tool for imaging sample magnetization, currents, and susceptibilities with higher spatial resolution than previous susceptometers.

  15. ROLE OF SPATIAL RESOLUTION AND SPECTRAL CONTENT IN CHANGE DETECTION.

    USGS Publications Warehouse

    Milazzo, Valerie A.

    1984-01-01

    Summary form only given, as follows. Advancements in remote sensing technology have brought improvements and sophistication to modern remote sensor systems, especially those aboard earth resources satellites. These improvements have considerbly expanded the capabilities of the newer sensor systems, particularly the capability to achieve greatly increased spatial and spectral resolution levels. The debate still lingers, however, over whether future systems should maximize spatial resolution or spectral information, or both. As yet, the high costs and large volumes of data associated with even modest incremental improvements in spatial and spectral content have precluded the design of a single system that attempts to fully optimize both. Thus, the user is faced with having to choose between those systems providing high spatial resolutions but limited spectral information and those which offer a broad range of spectral data but hold spatial resolution to a less than optimum level. In this study, the contribution of both spatial resolution and spectral content to land cover change detection is examined. Ten-meter SPOT simulation imagery is compared with multispectral images acquired by the Thematic Mapper sensor system for use in the visual interpretation and mapping of changes. Several image processing and enhancement techniques are utilized to maximize the spatial and spectral data content offered by each system. Results indicate that when using visual image interpretation techniques to detect change, higher spatial resolutions are generally preferred over increased spectral content.

  16. Solar system events at high spatial resolution

    SciTech Connect

    Baines, K H; Gavel, D T; Getz, A M; Gibbartd, S G; MacIntosh, B; Max, C E; McKay, C P; Young, E F; de Pater, I

    1999-02-19

    Until relatively recent advances in technology, astronomical observations from the ground were limited in image resolution by the blurring effects of earth's atmosphere. The blur extent, ranging typically from 0.5 to 2 seconds of arc at the best astronomical sights, precluded ground-based observations of the details of the solar system's moons, asteroids, and outermost planets. With the maturing of a high resolution image processing technique called speckle imaging the resolution limitation of the atmosphere can now be largely overcome. Over the past three years they have used speckle imaging to observe Titan, a moon of Saturn with an atmospheric density comparable to Earth's, Io, the volcanically active innermost moon of Jupiter, and Neptune, a gas giant outer planet which has continually changing planet-encircling storms. These observations were made at the world's largest telescope, the Keck telescope in Hawaii and represent the highest resolution infrared images of these objects ever taken.

  17. Results of the spatial resolution simulation for multispectral data (resolution brochures)

    NASA Technical Reports Server (NTRS)

    1982-01-01

    The variable information content of Earth Resource products at different levels of spatial resolution and in different spectral bands is addressed. A low-cost brochure that scientists and laymen could use to visualize the effects of increasing the spatial resolution of multispectral scanner images was produced.

  18. Preliminary evaluation of a monolithic detector module for integrated PET/MRI scanner with high spatial resolution

    NASA Astrophysics Data System (ADS)

    Pani, R.; Gonzalez, A. J.; Bettiol, M.; Fabbri, A.; Cinti, M. N.; Preziosi, E.; Borrazzo, C.; Conde, P.; Pellegrini, R.; Di Castro, E.; Majewski, S.

    2015-06-01

    The proposal of Mindview European Project concerns with the development of a very high resolution and high efficiency brain dedicated PET scanner simultaneously working with a Magnetic Resonance scanner, that expects to visualize neurotransmitter pathways and their disruptions in the quest to better diagnose schizophrenia. On behalf of this project, we propose a low cost PET module for the first prototype, based on monolithic crystals, suitable to be integrated with a head Radio Frequency (RF) coil. The aim of the suggested module is to achieve high performances in terms of efficiency, planar spatial resolution (expected about 1 mm) and discrimination of gamma Depth Of Interaction (DOI) in order to reduce the parallax error. Our preliminary results are very promising: a DOI resolution of about 3 mm, a spatial resolution ranging from about 1 to 1.5 mm and a good position linearity.

  19. Analysis of DOA estimation spatial resolution using MUSIC algorithm

    NASA Astrophysics Data System (ADS)

    Guo, Yue; Wang, Hongyuan; Luo, Bin

    2005-11-01

    This paper presents a performance analysis of the spatial resolution of the direction of arrival (DOA) estimates attained by the multiple signal classification (MUSIC) algorithm for uncorrelated sources. The confidence interval of estimation angle which is much more intuitionistic will be considered as the new evaluation standard for the spatial resolution. Then, based on the statistic method, the qualitative analysis reveals the factors influencing the performance of the MUSIC algorithm. At last, quantitative simulations prove the theoretical analysis result exactly.

  20. Radiometric and Spatial Characterization of High-Spatial Resolution Sensors

    NASA Technical Reports Server (NTRS)

    Thome, Kurtis; Zanoni, Vicki (Technical Monitor)

    2002-01-01

    The development and improvement of commercial hyperspatial sensors in recent years has increased the breadth of information that can be retrieved from spaceborne and airborne imagery. NASA, through it's Scientific Data Purchases, has successfully provided such data sets to its user community. A key element to the usefulness of these data are an understanding of the radiometric and spatial response quality of the imagery. This proposal seeks funding to examine the absolute radiometric calibration of the Ikonos sensor operated by Space Imaging and the recently-launched Quickbird sensor from DigitalGlobe. In addition, we propose to evaluate the spatial response of the two sensors. The proposed methods rely on well-understood, ground-based targets that have been used by the University of Arizona for more than a decade.

  1. IKONOS Spatial Resolution and Image Interpretability Characterization

    NASA Technical Reports Server (NTRS)

    Ryan, Robert; Baldridge, Braxton; Schowengerdt, Robert A.; Choi, Taeyoung; Helder, Dennis L.; Blonski, Slawomir

    2003-01-01

    This paper contains research from five individual projects to characterize the spatial performance of the IKONOS commercial imaging sensor. The end result of the projects is determination of the spatial image quality of IKONOS data prodicts in terms of the National Imagery Interpretability Rating Scale (NIIRS), the system Modulation Transfer Function (MTF), the system stability over the first year, the characteristics of the Space Imaging MTF Compensation (MTFC) procedure, and the application-specific capabilities of IKONOS imagery. Both panchromatic and multispectral imagery were evaluated. Major conclusions of this work are that the system was stable im imaging performance during the first year of operation, tha its MTF meets the specification for the NASA Scientific Data Purchase program, that the initial MTFC processing appears to be transposed in the in-track and the cross-track directions, that the MTFC results in a noise amplification of 2x to 4x in addition to sharpening the imagery, and that IKONOS panchromatic imagery achieves an average NIIRS rating of 4.5.

  2. Improving Nano-MRI Spatial Resolution with Phase Multiplexing

    NASA Astrophysics Data System (ADS)

    Moores, Brad; Eichler, Alex; Degen, Christian

    2015-03-01

    Magnetic resonance force microscopy (MRFM) is a scanning probe technique that allows measuring nuclear spin densities with resolution better than 10nm. Detecting such small volumes of spins (less than (10nm)3 corresponds to approximately 20,000 spins) requires long averaging of signals from statistically polarized nuclei. For instance, previous work demonstrated that imaging a single isotope (1H) of a Tobacco Mosaic Virus required averaging for 2 weeks, and therefore the chemical contrast abilities of MRFM had to be forfeited to enable higher spatial resolution. In order to reconcile the chemical selectivity of MRFM along with the proven high spatial resolution, we have developed a phase multiplexing technique capable of simultaneously acquiring spin signals from multiple isotopes and from up to six spatial locations. We have demonstrated this method using a nanowire test sample, and have achieved one-dimensional imaging resolution of less than 5 nm and subnanometer positional accuracy.

  3. A Very High Spatial Resolution Detector for Small Animal PET

    SciTech Connect

    Kanai Shah, M.S.

    2007-03-06

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated.

  4. Full Spatial Resolution Infrared Sounding Application in the Preconvection Environment

    NASA Astrophysics Data System (ADS)

    Liu, C.; Liu, G.; Lin, T.

    2013-12-01

    Advanced infrared (IR) sounders such as the Atmospheric Infrared Sounder (AIRS) and Infrared Atmospheric Sounding Interferometer (IASI) provide atmospheric temperature and moisture profiles with high vertical resolution and high accuracy in preconvection environments. The derived atmospheric stability indices such as convective available potential energy (CAPE) and lifted index (LI) from advanced IR soundings can provide critical information 1 ; 6 h before the development of severe convective storms. Three convective storms are selected for the evaluation of applying AIRS full spatial resolution soundings and the derived products on providing warning information in the preconvection environments. In the first case, the AIRS full spatial resolution soundings revealed local extremely high atmospheric instability 3 h ahead of the convection on the leading edge of a frontal system, while the second case demonstrates that the extremely high atmospheric instability is associated with the local development of severe thunderstorm in the following hours. The third case is a local severe storm that occurred on 7-8 August 2010 in Zhou Qu, China, which caused more than 1400 deaths and left another 300 or more people missing. The AIRS full spatial resolution LI product shows the atmospheric instability 3.5 h before the storm genesis. The CAPE and LI from AIRS full spatial resolution and operational AIRS/AMSU soundings along with Geostationary Operational Environmental Satellite (GOES) Sounder derived product image (DPI) products were analyzed and compared. Case studies show that full spatial resolution AIRS retrievals provide more useful warning information in the preconvection environments for determining favorable locations for convective initiation (CI) than do the coarser spatial resolution operational soundings and lower spectral resolution GOES Sounder retrievals. The retrieved soundings are also tested in a regional data assimilation WRF 3D-var system to evaluate the

  5. High spatial resolution measurements of ram accelerator gas dynamic phenomena

    NASA Technical Reports Server (NTRS)

    Hinkey, J. B.; Burnham, E. A.; Bruckner, A. P.

    1992-01-01

    High spatial resolution experimental tube wall pressure measurements of ram accelerator gas dynamic phenomena are presented. The projectile resembles the centerbody of a ramjet and travels supersonically through a tube filled with a combustible gaseous mixture, with the tube acting as the outer cowling. Pressure data are recorded as the projectile passes by sensors mounted in the tube wall at various locations along the tube. Data obtained by using a special highly instrumented section of tube has allowed the recording of gas dynamic phenomena with a spatial resolution on the order of one tenth the projectile length. High spatial resolution tube wall pressure data from the three regimes of propulsion studied to date (subdetonative, transdetonative, and superdetonative) are presented and reveal the 3D character of the flowfield induced by projectile fins and the canting of the projectile body relative to the tube wall. Also presented for comparison to the experimental data are calculations made with an inviscid, 3D CFD code.

  6. Improved Spatial Resolution For Reflection Mode Infrared Spectromicroscopy

    SciTech Connect

    Bechtel, Hans A; Martin, Michael C.; May, T. E.; Lerch, Philippe

    2009-08-13

    Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the numerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using a microscope coupled to a synchrotron source.

  7. Line integration and spatial resolution in optical imaging of plasmas

    NASA Astrophysics Data System (ADS)

    Siepa, Sarah; Czarnetzki, Uwe

    2015-09-01

    Optical emission spectroscopy of plasmas is a commonly used line-integrated method. In an attempt to enhance the spatial resolution along the line of sight, lenses are often used. To judge the benefit of this measure, a detection function is derived, which describes the amount of light detected from different positions along the optical axis of the lens-detector-system. Although certain points within the plasma are more sharply imaged by the lens system than others, the overall detection function is found to be almost perfectly flat, i.e. the lens does not yield any spatial resolution.

  8. Quantifying mangrove chlorophyll from high spatial resolution imagery

    NASA Astrophysics Data System (ADS)

    Heenkenda, Muditha K.; Joyce, Karen E.; Maier, Stefan W.; de Bruin, Sytze

    2015-10-01

    Lower than expected chlorophyll concentration of a plant can directly limit photosynthetic activity, and resultant primary production. Low chlorophyll concentration may also indicate plant physiological stress. Compared to other terrestrial vegetation, mangrove chlorophyll variations are poorly understood. This study quantifies the spatial distribution of mangrove canopy chlorophyll variation using remotely sensed data and field samples over the Rapid Creek mangrove forest in Darwin, Australia. Mangrove leaf samples were collected and analyzed for chlorophyll content in the laboratory. Once the leaf area index (LAI) of sampled trees was estimated using the digital cover photography method, the canopy chlorophyll contents were calculated. Then, the nonlinear random forests regression algorithm was used to describe the relationship between canopy chlorophyll content and remotely sensed data (WorldView-2 satellite image bands and their spectral transformations), and to estimate the spatial distribution of canopy chlorophyll variation. The imagery was evaluated at full 2 m spatial resolution, as well as at decreased resampled resolutions of 5 m and 10 m. The root mean squared errors with validation samples were 0.82, 0.64 and 0.65 g/m2 for maps at 2 m, 5 m and 10 m spatial resolution respectively. The correlation coefficient was analyzed for the relationship between measured and predicted chlorophyll values. The highest correlation: 0.71 was observed at 5 m spatial resolution (R2 = 0.5). We therefore concluded that estimating mangrove chlorophyll content from remotely sensed data is possible using red, red-edge, NIR1 and NIR2 bands and their spectral transformations as predictors at 5 m spatial resolution.

  9. Spatially Patterned Electrical Stimulation to Enhance Resolution of Retinal Prostheses

    PubMed Central

    Hottowy, Paweł; Mathieson, Keith; Gunning, Deborah E.; Dąbrowski, Władysław; Litke, Alan M.; Chichilnisky, E. J.

    2014-01-01

    Retinal prostheses electrically stimulate neurons to produce artificial vision in people blinded by photoreceptor degenerative diseases. The limited spatial resolution of current devices results in indiscriminate stimulation of interleaved cells of different types, precluding veridical reproduction of natural activity patterns in the retinal output. Here we investigate the use of spatial patterns of current injection to increase the spatial resolution of stimulation, using high-density multielectrode recording and stimulation of identified ganglion cells in isolated macaque retina. As previously shown, current passed through a single electrode typically induced a single retinal ganglion cell spike with submillisecond timing precision. Current passed simultaneously through pairs of neighboring electrodes modified the probability of activation relative to injection through a single electrode. This modification could be accurately summarized by a piecewise linear model of current summation, consistent with a simple biophysical model based on multiple sites of activation. The generalizability of the piecewise linear model was tested by using the measured responses to stimulation with two electrodes to predict responses to stimulation with three electrodes. Finally, the model provided an accurate prediction of which among a set of spatial stimulation patterns maximized selective activation of a cell while minimizing activation of a neighboring cell. The results demonstrate that tailored multielectrode stimulation patterns based on a piecewise linear model may be useful in increasing the spatial resolution of retinal prostheses. PMID:24695706

  10. Improved Spatial Resolution for Reflection Mode Infrared Microscopy

    SciTech Connect

    Bechtel, Hans A.; Martin, Michael C.; May, T.E.; Lerch, Philippe

    2009-10-09

    Standard commercial infrared microscopes operating in reflection mode use a mirror to direct the reflected light from the sample to the detector. This mirror blocks about half of the incident light, however, and thus degrades the spatial resolution by reducing the umerical aperture of the objective. Here, we replace the mirror with a 50% beamsplitter to allow full illumination of the objective and retain a way to direct the reflected light to the detector. The improved spatial resolution is demonstrated using two different microscopes apable of diffraction-limited resolution: the first microscope is coupled to a synchrotron source and utilizes a single point detector, whereas the second microscope has a standard blackbody source and uses a focal planetarray (FPA) detector.

  11. Spatial Resolution Requirements for MODIS-N. [Polar Platform Moderate Resolution Imaging Spectrometer (MODIS)

    NASA Technical Reports Server (NTRS)

    Townshend, J. R. G.; Justice, C. O.; Markham, B. L.; Briggs, S. A.

    1988-01-01

    An empirical investigation of the required spatial resolution for MODIS-N is outlined. It is based on 5 LANDSAT multispectral scanner system images of the normalized difference vegetation index degraded to resolutions between 250 m and 4000 m. Pairs of images from different dates were registered and difference images were generated. Fourier analysis indicates that resolutions finer than 1 km are highly desirable for change detection. A sensor with a resolution of 500 m is recommended as providing the best compromise between detail of changes detected and the size of the resultant data volume, but other options are also suggested.

  12. Evolution of spatial resolution in breast CT at UC Davis

    SciTech Connect

    Gazi, Peymon M.; Yang, Kai; Burkett, George W.; Aminololama-Shakeri, Shadi; Anthony Seibert, J.; Boone, John M.

    2015-04-15

    Purpose: Dedicated breast computed tomography (bCT) technology for the purpose of breast cancer screening has been a focus of research at UC Davis since the late 1990s. Previous studies have shown that improvement in spatial resolution characteristics of this modality correlates with greater microcalcification detection, a factor considered a potential limitation of bCT. The aim of this study is to improve spatial resolution as characterized by the modulation transfer function (MTF) via changes in the scanner hardware components and operational schema. Methods: Four prototypes of pendant-geometry, cone-beam breast CT scanners were designed and developed spanning three generations of design evolution. To improve the system MTF in each bCT generation, modifications were made to the imaging components (x-ray tube and flat-panel detector), system geometry (source-to-isocenter and detector distance), and image acquisition parameters (technique factors, number of projections, system synchronization scheme, and gantry rotational speed). Results: Characterization of different generations of bCT systems shows these modifications resulted in a 188% improvement of the limiting MTF properties from the first to second generation and an additional 110% from the second to third. The intrinsic resolution degradation in the azimuthal direction observed in the first generation was corrected by changing the acquisition from continuous to pulsed x-ray acquisition. Utilizing a high resolution detector in the third generation, along with modifications made in system geometry and scan protocol, resulted in a 125% improvement in limiting resolution. An additional 39% improvement was obtained by changing the detector binning mode from 2 × 2 to 1 × 1. Conclusions: These results underscore the advancement in spatial resolution characteristics of breast CT technology. The combined use of a pulsed x-ray system, higher resolution flat-panel detector and changing the scanner geometry and image

  13. Evolution of spatial resolution in breast CT at UC Davis

    PubMed Central

    Gazi, Peymon M.; Yang, Kai; Burkett, George W.; Aminololama-Shakeri, Shadi; Anthony Seibert, J.; Boone, John M.

    2015-01-01

    Purpose: Dedicated breast computed tomography (bCT) technology for the purpose of breast cancer screening has been a focus of research at UC Davis since the late 1990s. Previous studies have shown that improvement in spatial resolution characteristics of this modality correlates with greater microcalcification detection, a factor considered a potential limitation of bCT. The aim of this study is to improve spatial resolution as characterized by the modulation transfer function (MTF) via changes in the scanner hardware components and operational schema. Methods: Four prototypes of pendant-geometry, cone-beam breast CT scanners were designed and developed spanning three generations of design evolution. To improve the system MTF in each bCT generation, modifications were made to the imaging components (x-ray tube and flat-panel detector), system geometry (source-to-isocenter and detector distance), and image acquisition parameters (technique factors, number of projections, system synchronization scheme, and gantry rotational speed). Results: Characterization of different generations of bCT systems shows these modifications resulted in a 188% improvement of the limiting MTF properties from the first to second generation and an additional 110% from the second to third. The intrinsic resolution degradation in the azimuthal direction observed in the first generation was corrected by changing the acquisition from continuous to pulsed x-ray acquisition. Utilizing a high resolution detector in the third generation, along with modifications made in system geometry and scan protocol, resulted in a 125% improvement in limiting resolution. An additional 39% improvement was obtained by changing the detector binning mode from 2 × 2 to 1 × 1. Conclusions: These results underscore the advancement in spatial resolution characteristics of breast CT technology. The combined use of a pulsed x-ray system, higher resolution flat-panel detector and changing the scanner geometry and image

  14. High Spatial Resolution Observations of Two Young Protostars in the R Corona Australis Region

    NASA Astrophysics Data System (ADS)

    Groppi, Christopher E.; Hunter, Todd R.; Blundell, Raymond; Sandell, Göran

    2007-11-01

    We present multiwavelength, high spatial resolution imaging of the IRS 7 region in the R Corona Australis molecular cloud. Our observations include 1.1 mm continuum and HCO+ J=3-->2 images from the Submillimeter Array (SMA), 12CO J=3-->2 outflow maps from the DesertStar heterodyne array receiver on the Heinrich Hertz Telescope (HHT), 450 and 850 μm continuum images from SCUBA, and archival Spitzer IRAC and MIPS 24 μm images. The accurate astrometry of the IRAC images allow us to identify IRS 7 with the centimeter source VLA 10W (IRS 7A) and the X-ray source XW. The SMA 1.1 mm image reveals two compact continuum sources that are also distinguishable at 450 μm. SMA 1 coincides with X-ray source CXOU J190156.4-365728 and VLA centimeter source 10E (IRS 7B) and is seen in the IRAC and MIPS images. SMA 2 has no infrared counterpart but coincides with centimeter source VLA 9. Spectral energy distributions constructed from SMA, SCUBA, and Spitzer data yield bolometric temperatures of 83 K for SMA 1 and <=70 K for SMA 2. These temperatures along with the submillimeter to total luminosity ratios indicate that SMA 2 is a Class 0 protostar, while SMA 1 is a Class 0/Class I transitional object (L=17+/-6 Lsolar). The 12CO J=3-->2 outflow map shows one major and possibly several smaller outflows centered on the IRS 7 region, with masses and energetics consistent with previous work. We identify the Class 0 source SMA 2/VLA 9 as the main driver of this outflow. The complex and clumpy spatial and velocity distribution of the HCO+ J=3-->2 emission is not consistent with either bulk rotation, or any known molecular outflow activity.

  15. 3D spatial resolution and spectral resolution of interferometric 3D imaging spectrometry.

    PubMed

    Obara, Masaki; Yoshimori, Kyu

    2016-04-01

    Recently developed interferometric 3D imaging spectrometry (J. Opt. Soc. Am A18, 765 [2001]1084-7529JOAOD610.1364/JOSAA.18.000765) enables obtainment of the spectral information and 3D spatial information for incoherently illuminated or self-luminous object simultaneously. Using this method, we can obtain multispectral components of complex holograms, which correspond directly to the phase distribution of the wavefronts propagated from the polychromatic object. This paper focuses on the analysis of spectral resolution and 3D spatial resolution in interferometric 3D imaging spectrometry. Our analysis is based on a novel analytical impulse response function defined over four-dimensional space. We found that the experimental results agree well with the theoretical prediction. This work also suggests a new criterion and estimate method regarding 3D spatial resolution of digital holography. PMID:27139648

  16. Spatial resolution of a hard x-ray CCD detector

    SciTech Connect

    Seely, John F.; Pereira, Nino R.; Weber, Bruce V.; Schumer, Joseph W.; Apruzese, John P.; Hudson, Lawrence T.; Szabo, Csilla I.; Boyer, Craig N.; Skirlo, Scott

    2010-08-10

    The spatial resolution of an x-ray CCD detector was determined from the widths of the tungsten x-ray lines in the spectrum formed by a crystal spectrometer in the 58 to 70 keV energy range. The detector had 20{mu}m pixel, 1700 by 1200 pixel format, and a CsI x-ray conversion scintillator. The spectral lines from a megavolt x-ray generator were focused on the spectrometer's Rowland circle by a curved transmission crystal. The line shapes were Lorentzian with an average width after removal of the natural and instrumental line widths of 95{mu}m (4.75 pixels). A high spatial frequency background, primarily resulting from scattered gamma rays, was removed from the spectral image by Fourier analysis. The spectral lines, having low spatial frequency in the direction perpendicular to the dispersion, were enhanced by partially removing the Lorentzian line shape and by fitting Lorentzian curves to broad unresolved spectral features. This demonstrates the ability to improve the spectral resolution of hard x-ray spectra that are recorded by a CCD detector with well-characterized intrinsic spatial resolution.

  17. Spatial resolution of a hard x-ray CCD detector.

    PubMed

    Seely, John F; Pereira, Nino R; Weber, Bruce V; Schumer, Joseph W; Apruzese, John P; Hudson, Lawrence T; Szabo, Csilla I; Boyer, Craig N; Skirlo, Scott

    2010-08-10

    The spatial resolution of an x-ray CCD detector was determined from the widths of the tungsten x-ray lines in the spectrum formed by a crystal spectrometer in the 58 to 70 keV energy range. The detector had 20 microm pixel, 1700 by 1200 pixel format, and a CsI x-ray conversion scintillator. The spectral lines from a megavolt x-ray generator were focused on the spectrometer's Rowland circle by a curved transmission crystal. The line shapes were Lorentzian with an average width after removal of the natural and instrumental line widths of 95 microm (4.75 pixels). A high spatial frequency background, primarily resulting from scattered gamma rays, was removed from the spectral image by Fourier analysis. The spectral lines, having low spatial frequency in the direction perpendicular to the dispersion, were enhanced by partially removing the Lorentzian line shape and by fitting Lorentzian curves to broad unresolved spectral features. This demonstrates the ability to improve the spectral resolution of hard x-ray spectra that are recorded by a CCD detector with well-characterized intrinsic spatial resolution.

  18. Spatially resolved and observer-free experimental quantification of spatial resolution in tomographic images

    SciTech Connect

    Tsekenis, S. A.; McCann, H.; Tait, N.

    2015-03-15

    We present a novel framework and experimental method for the quantification of spatial resolution of a tomography system. The framework adopts the “black box” view of an imaging system, considering only its input and output. The tomography system is locally stimulated with a step input, viz., a sharp edge. The output, viz., the reconstructed images, is analysed by Fourier decomposition of their spatial frequency components, and the local limiting spatial resolution is determined using a cut-off threshold. At no point is an observer involved in the process. The framework also includes a means of translating the quantification region in the imaging space, thus creating a spatially resolved map of objectively quantified spatial resolution. As a case-study, the framework is experimentally applied using a gaseous propane phantom measured by a well-established chemical species tomography system. A spatial resolution map consisting of 28 regions is produced. In isolated regions, the indicated performance is 4-times better than that suggested in the literature and varies by 57% across the imaging space. A mechanism based on adjacent but non-interacting beams is hypothesised to explain the observed behaviour. The mechanism suggests that, as also independently concluded by other methods, a geometrically regular beam array maintains maximum objectivity in reconstructions. We believe that the proposed framework, methodology, and findings will be of value in the design and performance evaluation of tomographic imaging arrays and systems.

  19. Subcell resolution in simplex stochastic collocation for spatial discontinuities

    SciTech Connect

    Witteveen, Jeroen A.S.; Iaccarino, Gianluca

    2013-10-15

    Subcell resolution has been used in the Finite Volume Method (FVM) to obtain accurate approximations of discontinuities in the physical space. Stochastic methods are usually based on local adaptivity for resolving discontinuities in the stochastic dimensions. However, the adaptive refinement in the probability space is ineffective in the non-intrusive uncertainty quantification framework, if the stochastic discontinuity is caused by a discontinuity in the physical space with a random location. The dependence of the discontinuity location in the probability space on the spatial coordinates then results in a staircase approximation of the statistics, which leads to first-order error convergence and an underprediction of the maximum standard deviation. To avoid these problems, we introduce subcell resolution into the Simplex Stochastic Collocation (SSC) method for obtaining a truly discontinuous representation of random spatial discontinuities in the interior of the cells discretizing the probability space. The presented SSC–SR method is based on resolving the discontinuity location in the probability space explicitly as function of the spatial coordinates and extending the stochastic response surface approximations up to the predicted discontinuity location. The applications to a linear advection problem, the inviscid Burgers’ equation, a shock tube problem, and the transonic flow over the RAE 2822 airfoil show that SSC–SR resolves random spatial discontinuities with multiple stochastic and spatial dimensions accurately using a minimal number of samples.

  20. High spatial-resolution IRAS images of M51

    NASA Technical Reports Server (NTRS)

    Canterna, R.; Hackwell, John A.; Grasdalen, Gary L.

    1990-01-01

    High spatial-resolution (approx. equal to 30 seconds) images of M51 in the four Infrared Astronomy Satellite (IRAS) bands (12, 25, 60, and 100 microns) have been obtained. The spatial variation in flux in all four bands is coincident with the spiral features seen in H alpha and 6 cm with a few exceptions. In the nuclear region (4 minutes) the position of the peak of maximum intensity shifts in relation to the visual nucleus: it is coincident with the nucleus at 12 microns, shifts approximately 45 seconds to south-southwest, and is 45 seconds northwest of the nucleus at 60 and 100 microns.

  1. HIGH SPATIAL RESOLUTION OBSERVATIONS OF LOOPS IN THE SOLAR CORONA

    SciTech Connect

    Brooks, David H.; Ugarte-Urra, Ignacio; Warren, Harry P.; Winebarger, Amy R.

    2013-08-01

    Understanding how the solar corona is structured is of fundamental importance to determine how the Sun's upper atmosphere is heated to high temperatures. Recent spectroscopic studies have suggested that an instrument with a spatial resolution of 200 km or better is necessary to resolve coronal loops. The High Resolution Coronal Imager (Hi-C) achieved this performance on a rocket flight in 2012 July. We use Hi-C data to measure the Gaussian widths of 91 loops observed in the solar corona and find a distribution that peaks at about 270 km. We also use Atmospheric Imaging Assembly data for a subset of these loops and find temperature distributions that are generally very narrow. These observations provide further evidence that loops in the solar corona are often structured at a scale of several hundred kilometers, well above the spatial scale of many proposed physical mechanisms.

  2. CRISTA, a cryogenic IR telescope with high spatial resolution

    SciTech Connect

    Barthol, P.; Grossmann, K.U.; Offermann, D.

    1994-12-31

    A limb sounding cryogenic IR telescope named CRISTA (CRyogenic Infrared Spectrometers and Telescopes for the Atmosphere) has been developed to study dynamic disturbances in the middle atmosphere with high spatial (horizontal and vertical) resolution. For this purpose, it measures mid and far IR emissions of several trace constituents at earth`s limb using three independent telescopes with high off-axis rejection performance. Height profiles are derived from simultaneous scans of the three telescope LOS. The radiation received is spectrally analyzed by gating spectrometers followed by Si:Ga and Ge:Ga detectors. High sensitivity together with improved spatial resolution leads to a spacing of only 500 km to 600 km between two adjacent measurement points and thus to a far more detailed picture of the atmosphere compared to present day satellite experiments. CRISTA, integrated in the free-flyer ASTROSPAS, will be launched 1994 by the Space Shuttle for a short duration mission and will be part of ATLAS 3.

  3. Improving OFDR spatial resolution by reducing external clock sampling error

    NASA Astrophysics Data System (ADS)

    Feng, Bowen; Liu, Kun; Liu, Tiegen; Jiang, Junfeng; Du, Yang

    2016-03-01

    Utilizing an auxiliary interferometer to produce external clock signals as the data acquirement clock is widely used to compensate the nonlinearity of the tunable laser source (TLS) in optical frequency domain reflectometry (OFDR). However, this method is not always accurate because of the large optical length difference of both arms in the auxiliary interferometer. To investigate the deviation, we study the source and influence of the external clock sampling error in OFDR system. Based on the model, we find that the sampling error declines with the increase of the TLS's optical frequency tuning rate. The spatial resolution can be as high as 4.8 cm and the strain sensing location accuracy can be up to 0.15 m at the measurement length of 310 m under the minimum sampling error with the optical frequency tuning rate of 2500 GHz/s. Hence, the spatial resolution can be improved by reducing external clock sampling error in OFDR system.

  4. Imaging metals in biology: balancing sensitivity, selectivity and spatial resolution.

    PubMed

    Hare, Dominic J; New, Elizabeth J; de Jonge, Martin D; McColl, Gawain

    2015-10-01

    Metal biochemistry drives a diverse range of cellular processes associated with development, health and disease. Determining metal distribution, concentration and flux defines our understanding of these fundamental processes. A comprehensive analysis of biological systems requires a balance of analytical techniques that inform on metal quantity (sensitivity), chemical state (selectivity) and location (spatial resolution) with a high degree of certainty. A number of approaches are available for imaging metals from whole tissues down to subcellular organelles, as well as mapping metal turnover, protein association and redox state within these structures. Technological advances in micro- and nano-scale imaging are striving to achieve multi-dimensional and in vivo measures of metals while maintaining the native biochemical environment and physiological state. This Tutorial Review discusses state-of-the-art imaging technology as a guide to obtaining novel insight into the biology of metals, with sensitivity, selectivity and spatial resolution in focus. PMID:26505053

  5. Advanced Remote-Sensing Imaging Emission Spectrometer (ARIES): AIRS Spectral Resolution with MODIS Spatial Resolution

    NASA Technical Reports Server (NTRS)

    Pagano, Thomas S.; Chahine, Moustafa T.; Aumann, Hartmut H.; OCallaghan, Fred

    2006-01-01

    The Advanced Remote-sensing Imaging Emission Spectrometer (ARIES) will measure a wide range of earth quantities fundamental to the study of global climate change. It will build upon the success of the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Atmospheric Infrared Sounder (AIRS) instruments currently flying on the EOS Aqua Spacecraft. Both instruments are facility instruments for NASA providing data to thousands of scientists investigating land, ocean and atmospheric Earth System processes. ARIES will meet all the requirements of AIRS and MODIS in a single compact instrument, while providing the next-generation capability of improved spatial resolution for AIRS and improved spectral resolution for MODIS.

  6. Sub-pixel spatial resolution wavefront phase imaging

    NASA Technical Reports Server (NTRS)

    Stahl, H. Philip (Inventor); Mooney, James T. (Inventor)

    2012-01-01

    A phase imaging method for an optical wavefront acquires a plurality of phase images of the optical wavefront using a phase imager. Each phase image is unique and is shifted with respect to another of the phase images by a known/controlled amount that is less than the size of the phase imager's pixels. The phase images are then combined to generate a single high-spatial resolution phase image of the optical wavefront.

  7. Spatial and spectral resolution necessary for remotely sensed vegetation studies

    NASA Technical Reports Server (NTRS)

    Rock, B. N.

    1982-01-01

    An outline is presented of the required spatial and spectral resolution needed for accurate vegetation discrimination and mapping studies as well as for determination of state of health (i.e., detection of stress symptoms) of actively growing vegetation. Good success was achieved in vegetation discrimination and mapping of a heterogeneous forest cover in the ridge and valley portion of the Appalachians using multispectral data acquired with a spatial resolution of 15 m (IFOV). A sensor system delivering 10 to 15 m spatial resolution is needed for both vegetation mapping and detection of stress symptoms. Based on the vegetation discrimination and mapping exercises conducted at the Lost River site, accurate products (vegetation maps) are produced using broad-band spectral data ranging from the .500 to 2.500 micron portion of the spectrum. In order of decreasing utility for vegetation discrimination, the four most valuable TM simulator VNIR bands are: 6 (1.55 to 1.75 microns), 3 (0.63 to 0.69 microns), 5 (1.00 to 1.30 microns) and 4 (0.76 to 0.90 microns).

  8. Wide band focusing x-ray spectrograph with spatial resolution

    SciTech Connect

    Pikuz, S. A.; Douglass, J. D.; Shelkovenko, T. A.; Sinars, D. B.; Hammer, D. A.

    2008-01-15

    A new, wide spectral bandwidth x-ray spectrograph, the wide-bandwidth focusing spectrograph with spatial resolution (WB-FSSR), based on spherically bent mica crystals, is described. The wide bandwidth is achieved by combining three crystals to form a large aperture dispersive element. Since the WB-FSSR covers a wide spectral band, it is very convenient for application as a routine diagnostic tool in experiments in which the desired spectral coverage is different from one test to the next. The WB-FSSR has been tested in imploding wire-array experiments on a 1 MA pulsed power machine, and x-ray spectra were recorded in the 1-20 A spectral band using different orders of mica crystal reflection. Using a two mirror-symmetrically placed WB-FSSR configuration, it was also possible to distinguish between a real spectral shift and a shift of recorded spectral lines caused by the spatial distribution of the radiating plasma. A spectral resolution of about 2000 was demonstrated and a spatial resolution of {approx}100 {mu}m was achieved in the spectral band of 5-10 A in second order of mica reflection. A simple method of numerical analysis of spectrograph capability is proposed.

  9. Science with High Spatial Resolution Far-Infrared Data

    NASA Technical Reports Server (NTRS)

    Terebey, Susan (Editor); Mazzarella, Joseph M. (Editor)

    1994-01-01

    The goal of this workshop was to discuss new science and techniques relevant to high spatial resolution processing of far-infrared data, with particular focus on high resolution processing of IRAS data. Users of the maximum correlation method, maximum entropy, and other resolution enhancement algorithms applicable to far-infrared data gathered at the Infrared Processing and Analysis Center (IPAC) for two days in June 1993 to compare techniques and discuss new results. During a special session on the third day, interested astronomers were introduced to IRAS HIRES processing, which is IPAC's implementation of the maximum correlation method to the IRAS data. Topics discussed during the workshop included: (1) image reconstruction; (2) random noise; (3) imagery; (4) interacting galaxies; (5) spiral galaxies; (6) galactic dust and elliptical galaxies; (7) star formation in Seyfert galaxies; (8) wavelet analysis; and (9) supernova remnants.

  10. Photoacoustic lymphatic imaging with high spatial-temporal resolution

    NASA Astrophysics Data System (ADS)

    Martel, Catherine; Yao, Junjie; Huang, Chih-Hsien; Zou, Jun; Randolph, Gwendalyn J.; Wang, Lihong V.

    2014-11-01

    Despite its critical function in coordinating the egress of inflammatory and immune cells out of tissues and maintaining fluid balance, the causative role of lymphatic network dysfunction in pathological settings is still understudied. Engineered-animal models and better noninvasive high spatial-temporal resolution imaging techniques in both preclinical and clinical studies will help to improve our understanding of different lymphatic-related pathologic disorders. Our aim was to take advantage of our newly optimized noninvasive wide-field fast-scanning photoacoustic (PA) microcopy system to coordinately image the lymphatic vasculature and its flow dynamics, while maintaining high resolution and detection sensitivity. Here, by combining the optical-resolution PA microscopy with a fast-scanning water-immersible microelectromechanical system scanning mirror, we have imaged the lymph dynamics over a large field-of-view, with high spatial resolution and advanced detection sensitivity. Depending on the application, lymphatic vessels (LV) were spectrally or temporally differentiated from blood vessels. Validation experiments were performed on phantoms and in vivo to identify the LV. Lymphatic flow dynamics in nonpathological and pathological conditions were also visualized. These results indicate that our newly developed PA microscopy is a promising tool for lymphatic-related biological research.

  11. High-resolution TFT-LCD for spatial light modulator

    NASA Astrophysics Data System (ADS)

    Lee, JaeWon; Kim, Yong-Hae; Byun, Chun-Won; Pi, Jae-Eun; Oh, Himchan; Kim, GiHeon; Lee, Myung-Lae; Chu, Hye-Yong; Hwang, Chi-Sun

    2014-06-01

    SLM with very fine pixel pitch is needed for the holographic display system. Among various kinds of SLMs, commercially available high resolution LCoS has been widely used as a spatial light modulator. But the size of commercially available LCoS SLM is limited because the manufacturing technology of LCoS is based on the semiconductor process developed on small size Si wafer. Recently very high resolution flat panel display panel (~500ppi) was developed as a "retina display". Until now, the pixel pitch of flat panel display is several times larger than the pixel pitch of LCoS. But considering the possibility of shrink down the pixel pitch with advanced lithographic tools, the application of flat panel display will make it possible to build a SLM with high spatial bandwidth product. We simulated High resolution TFT-LCD panel on glass substrate using oxide semiconductor TFT with pixel pitch of 20um. And we considered phase modulation behavior of LC(ECB) mode. The TFT-LCD panel is reflective type with 4-metal structure with organic planarization layers. The technical challenge for high resolution large area SLM will be discussed with very fine pixel.

  12. Photoacoustic lymphatic imaging with high spatial-temporal resolution.

    PubMed

    Martel, Catherine; Yao, Junjie; Huang, Chih-Hsien; Zou, Jun; Randolph, Gwendalyn J; Wang, Lihong V

    2014-11-01

    Despite its critical function in coordinating the egress of inflammatory and immune cells out of tissues and maintaining fluid balance, the causative role of lymphatic network dysfunction in pathological settings is still understudied. Engineered-animal models and better noninvasive high spatial-temporal resolution imaging techniques in both preclinical and clinical studies will help to improve our understanding of different lymphatic-related pathologic disorders. Our aim was to take advantage of our newly optimized noninvasive wide-field fast-scanning photoacoustic (PA) microcopy system to coordinately image the lymphatic vasculature and its flow dynamics, while maintaining high resolution and detection sensitivity. Here, by combining the optical-resolution PA microscopy with a fast-scanning water-immersible microelectromechanical system scanning mirror, we have imaged the lymph dynamics over a large field-of-view, with high spatial resolution and advanced detection sensitivity. Depending on the application, lymphatic vessels (LV) were spectrally or temporally differentiated from blood vessels. Validation experiments were performed on phantoms and in vivo to identify the LV. Lymphatic flow dynamics in nonpathological and pathological conditions were also visualized. These results indicate that our newly developed PA microscopy is a promising tool for lymphatic-related biological research.

  13. Advanced Remote-sensing Imaging Emission Spectrometer (ARIES): AIRS Spectral Resolution with MODIS Spatial Resolution

    NASA Technical Reports Server (NTRS)

    Pagano, Thomas S.; Chahine, Moustafa T.; Aumann, Hartmut H.; OCallaghan, Fred G.; Broberg, Steve E.

    2006-01-01

    This paper describes a space based instrument concept that will provide scientists with data needed to support key ongoing and future Earth System Science investigations. The measurement approach builds on the observations made by AIRS and MODIS and exceeds their capability with improved spatial and spectral resolution. This paper describes the expected products and the instrument concept that can meet those requirements.

  14. Effects of spatial configurations on the resolution of spatial working memory.

    PubMed

    Mutluturk, Aysu; Boduroglu, Aysecan

    2014-11-01

    Recent research demonstrated that people represent spatial information configurally and preservation of configural cues at retrieval helps memory for spatial locations (Boduroğlu & Shah, Memory & Cognition, 37(8), 1120-1131 2009; Jiang, Olson, & Chun, Journal of Experimental Psychology: Learning, Memory, and Cognition, 26(3), 683-702 2000). The present study investigated the effects of spatial configurations on the resolution of individual location representations. In an open-ended task, participants first studied a set of object locations (three and five locations). Then, in a test display where available configural cues were manipulated, participants were asked to determine the original location of a target object whose color was auditorially cued. The difference between the reported location and the original location was taken as a measure of spatial resolution. In three experiments, we consistently observed that the resolution of spatial representations was facilitated by the preservation of spatial configurations at retrieval. We argue that participants may be using available configural cues in conjunction with the summary representation (e.g., centroid) of the original display in the computation of target locations. PMID:24939236

  15. Agro-hydrology and multi temporal high resolution remote sensing: toward an explicit spatial processes calibration

    NASA Astrophysics Data System (ADS)

    Ferrant, S.; Gascoin, S.; Veloso, A.; Salmon-Monviola, J.; Claverie, M.; Rivalland, V.; Dedieu, G.; Demarez, V.; Ceschia, E.; Probst, J.-L.; Durand, P.; Bustillo, V.

    2014-07-01

    The recent and forthcoming availability of high resolution satellite image series offers new opportunities in agro-hydrological research and modeling. We investigated the perspective offered by improving the crop growth dynamic simulation using the distributed agro-hydrological model, Topography based Nitrogen transfer and Transformation (TNT2), using LAI map series derived from 105 Formosat-2 (F2) images during the period 2006-2010. The TNT2 model (Beaujouan et al., 2002), calibrated with discharge and in-stream nitrate fluxes for the period 1985-2001, was tested on the 2006-2010 dataset (climate, land use, agricultural practices, discharge and nitrate fluxes at the outlet). A priori agricultural practices obtained from an extensive field survey such as seeding date, crop cultivar, and fertilizer amount were used as input variables. Continuous values of LAI as a function of cumulative daily temperature were obtained at the crop field level by fitting a double logistic equation against discrete satellite-derived LAI. Model predictions of LAI dynamics with a priori input parameters showed an temporal shift with observed LAI profiles irregularly distributed in space (between field crops) and time (between years). By re-setting seeding date at the crop field level, we proposed an optimization method to minimize efficiently this temporal shift and better fit the crop growth against the spatial observations as well as crop production. This optimization of simulated LAI has a negligible impact on water budget at the catchment scale (1 mm yr-1 in average) but a noticeable impact on in-stream nitrogen fluxes (around 12%) which is of interest considering nitrate stream contamination issues and TNT2 model objectives. This study demonstrates the contribution of forthcoming high spatial and temporal resolution products of Sentinel-2 satellite mission in improving agro-hydrological modeling by constraining the spatial representation of crop productivity.

  16. Spatial Classification of Orchards and Vineyards with High Spatial Resolution Panchromatic Imagery

    SciTech Connect

    Warner, Timothy; Steinmaus, Karen L.

    2005-02-01

    New high resolution single spectral band imagery offers the capability to conduct image classifications based on spatial patterns in imagery. A classification algorithm based on autocorrelation patterns was developed to automatically extract orchards and vineyards from satellite imagery. The algorithm was tested on IKONOS imagery over Granger, WA, which resulted in a classification accuracy of 95%.

  17. High spatial resolution measurements in a single stage ram accelerator

    NASA Technical Reports Server (NTRS)

    Hinkey, J. B.; Burnham, E. A.; Bruckner, A. P.

    1992-01-01

    High spatial resolution experimental tube wall pressure measurements of ram accelerator gas dynamic phenomena are presented in this paper. The ram accelerator is a ramjet-in-tube device which operates in a manner similar to that of a conventional ramjet. The projectile resembles the centerbody of a ramjet and travels supersonically through a tube filled with a combustible gaseous mixture, with the tube acting as the outer cowling. Pressure data are recorded as the projectile passes by sensors mounted in the tube wall at various locations along the tube. Utilization of special highly instrumented sections of tube has allowed the recording of gas dynamic phenomena with high resolution. High spatial resolution tube wall pressure data from the three regimes of propulsion studied to date (subdetonative, transdetonative, and superdetonative) in a single stage gas mixture are presented and reveal the three-dimensional character of the flow field induced by projectile fins and the canting of the fins and the canting of the projectile body relative to the tube wall. Also presented for comparison to the experimental data are calculations made with an inviscid, three-dimensional CFD code. The knowledge gained from these experiments and simulations is useful in understanding the underlying nature of ram accelerator propulsive regimes, as well as assisting in the validation of three-dimensional CFD coded which model unsteady, chemically reactive flows.

  18. Joseph F. Keithley Award: Force microscopy with subatomic spatial resolution

    NASA Astrophysics Data System (ADS)

    Giessibl, Franz

    2014-03-01

    For a long time, atomic force microscopy has been inferior to the scanning tunneling microscope (STM) in its spatial resolution, partially because measurements of small forces are more challenging than measurements of small currents. With the introduction of frequency modulation force microscopy, the static deflection measurement of a cantilever under a tip-sample force was replaced by a frequency measurement of an oscillating cantilever induced by an average force gradient. Atomic resolution of the challenging silicon reconstruction by frequency modulation atomic force microscopy has been demonstrated in 1995 using a silicon cantilever with a stiffness of k = 17 N/m and an oscillation amplitude of A = 34 nm. In 1996, a quartz cantilever (``qPlus sensor''), originally built from a quartz tuning fork from a wristwatch, has been proposed. At k = 1800 N/m, this quartz sensor is 100 times stiffer than the original Si cantilever, allowing stable oscillation amplitudes down to fractions of an atomic diameter. It has a high Q factor, simple piezoelectric readout, little frequency variation with temperature and allows to simply mount metal tips as used in STM. The demonstration of high spatial resolution, the detection of very small forces, the capability to perform simultaneous STM and AFM as well as the ease of use of the qPlus sensor has led to its adaptation in leading scanning probe microscopy laboratories worldwide as well as in a growing number of commercial scanning probe instruments.

  19. Proceedings of the 2004 High Spatial Resolution Commercial Imagery Workshop

    NASA Technical Reports Server (NTRS)

    2006-01-01

    Topics covered include: NASA Applied Sciences Program; USGS Land Remote Sensing: Overview; QuickBird System Status and Product Overview; ORBIMAGE Overview; IKONOS 2004 Calibration and Validation Status; OrbView-3 Spatial Characterization; On-Orbit Modulation Transfer Function (MTF) Measurement of QuickBird; Spatial Resolution Characterization for QuickBird Image Products 2003-2004 Season; Image Quality Evaluation of QuickBird Super Resolution and Revisit of IKONOS: Civil and Commercial Application Project (CCAP); On-Orbit System MTF Measurement; QuickBird Post Launch Geopositional Characterization Update; OrbView-3 Geometric Calibration and Geopositional Accuracy; Geopositional Statistical Methods; QuickBird and OrbView-3 Geopositional Accuracy Assessment; Initial On-Orbit Spatial Resolution Characterization of OrbView-3 Panchromatic Images; Laboratory Measurement of Bidirectional Reflectance of Radiometric Tarps; Stennis Space Center Verification and Validation Capabilities; Joint Agency Commercial Imagery Evaluation (JACIE) Team; Adjacency Effects in High Resolution Imagery; Effect of Pulse Width vs. GSD on MTF Estimation; Camera and Sensor Calibration at the USGS; QuickBird Geometric Verification; Comparison of MODTRAN to Heritage-based Results in Vicarious Calibration at University of Arizona; Using Remotely Sensed Imagery to Determine Impervious Surface in Sioux Falls, South Dakota; Estimating Sub-Pixel Proportions of Sagebrush with a Regression Tree; How Do YOU Use the National Land Cover Dataset?; The National Map Hazards Data Distribution System; Recording a Troubled World; What Does This-Have to Do with This?; When Can a Picture Save a Thousand Homes?; InSAR Studies of Alaska Volcanoes; Earth Observing-1 (EO-1) Data Products; Improving Access to the USGS Aerial Film Collections: High Resolution Scanners; Improving Access to the USGS Aerial Film Collections: Phoenix Digitizing System Product Distribution; System and Product Characterization: Issues Approach

  20. Bioacoustic spatial perception by humans: a controlled laboratory measurement of spatial resolution without distal cues.

    PubMed

    Kay, L

    2001-02-01

    The angular spatial resolution of a wide-angle air sonar using a continuous transmission frequency-modulated radiation, with the output coupled binaurally to the auditory system of a user, was measured under restrained controlled conditions. This was done to determine the effect of adding a narrow central field of view of 9 deg to a wide-angle sonar. The target objects were three equidistant vertical rods initially spaced apart by 10 deg. This was varied down to a spacing of 4 deg. Ten nonvisual subjects achieved an angular resolution of 6 deg. Four of these ten subjects continued learning to achieve an unexpected spatial resolution of 4 deg within the 9 deg central field. A mean error of approximately 1 deg in direction accuracy was achieved. It is inferred that the unique variations in the octave band ultrasonic echoes within the narrow field, and the invariance of the on-axis echo as one's head is turned, enables this angular resolution and accuracy to be achieved within the wide binaural field of view of 50 deg. This ability to resolve specula objects within a narrow angular resolution element of 9 deg is linked to the bat's ability to seemingly resolve object glints within a distal resolution element of less than 2 wavelengths.

  1. The Grayscale/Spatial Resolution Trade-Off and Its Impact on Display System Design

    NASA Technical Reports Server (NTRS)

    Gille, Jennifer; Larimer, Jim; Martin, Russel; Statler, Irving C. (Technical Monitor)

    1994-01-01

    We examine technology trade-offs related to the grayscale/spatial resolution trade-off for AMLCD-based display systems. We present new empirical results from our study of the human grayscale/spatial resolution trade-off.

  2. High spatial resolution soft-x-ray microscopy

    SciTech Connect

    Meyer-Ilse, W.; Medecki, H.; Brown, J.T.

    1997-04-01

    A new soft x-ray microscope (XM-1) with high spatial resolution has been constructed by the Center for X-ray Optics. It uses bending magnet radiation from beamline 6.1 at the Advanced Light Source, and is used in a variety of projects and applications in the life and physical sciences. Most of these projects are ongoing. The instrument uses zone plate lenses and achieves a resolution of 43 nm, measured over 10% to 90% intensity with a knife edge test sample. X-ray microscopy permits the imaging of relatively thick samples, up to 10 {mu}m thick, in water. XM-1 has an easy to use interface, that utilizes visible light microscopy to precisely position and focus the specimen. The authors describe applications of this device in the biological sciences, as well as in studying industrial applications including structured polymer samples.

  3. An RPC-PET prototype with high spatial resolution

    NASA Astrophysics Data System (ADS)

    Blanco, A.; Carolino, N.; Correia, C. M. B. A.; Ferreira Marques, R.; Fonte, P.; González-Díaz, D.; Lindote, A.; Lopes, M. I.; Macedo, M. P.; Policarpo, A.

    2004-11-01

    A small positron emission tomography system, based on the timing RPC technology has been built and tested. This first prototype is aimed at validating the expectations, derived from simulations, of a very high spatial resolution, which could be of value for the imaging of small animals. The system is composed of two counting heads, able to measure the photon interaction point in two dimensions, the transaxial dimension and the Depth of Interaction. Each head is composed of 16 independent stacked RPCs made from copper and glass (anode) electrodes. Point-like 22Na sources were so far reconstructed, using the standard filtered back-projection algorithm, with a spatial accuracy of 0.6 mm FWHM, free of parallax error.

  4. Visualization of High Resolution Spatial Mass Spectrometric Data during Acquisition

    SciTech Connect

    Thomas, Mathew; Heath, Brandi S.; Laskin, Julia; Li, Dongsheng; Liu, Ellen C.; Hui, Katrina L.; Kuprat, Andrew P.; Kleese van Dam, Kerstin; Carson, James P.

    2012-08-28

    Mass Spectrometric Imaging (IMS) allows the generation of 2D ion density maps that help visualize molecules present in sections of tissues and cells. The combination of spatial and mass resolution results in large and complex data sets that require powerful and efficient analysis and interpretation. In this paper, a graphical user interface (GUI) that can visualize the large data during data acquisition itself is presented. The program also has the ability to perform processing and analysis of the dataset. The various functions of the GUI including visualization of mass spectra, generation of 2D maps for selected species, manipulation of the heat maps, and peak identification are also presented.

  5. Multichannel Thomson scattering systems with high spatial resolution (invited)

    SciTech Connect

    Johnson, D.; Bretz, N.; Dimock, D.; Grek, B.; Long, D.; Palladino, R.; Tolnas, E.

    1986-08-01

    Thomson scattering systems capable of providing snapshot profiles of electron temperature and density with high spatial resolution (>50 points) have become routine diagnostics on the Princeton large torus (PLT), Princeton divertor experiment (PDX), and tokamak fusion test reactor (TFTR) tokamaks. The design parameters of these systems are compared. Particular attention is given to describing those new components and techniques which have contributed most to improved data quality and reliability in the ten-year evolution of these systems. Examples of recent TFTR T-italic/sub e-italic/(R-italic) and n-italic/sub e-italic/(R-italic) profiles are presented.

  6. Multichannel Thomson scattering systems with high spatial resolution (invited)

    NASA Astrophysics Data System (ADS)

    Johnson, D.; Bretz, N.; Dimock, D.; Grek, B.; Long, D.; Palladino, R.; Tolnas, E.

    1986-08-01

    Thomson scattering systems capable of providing snapshot profiles of electron temperature and density with high spatial resolution (>50 points) have become routine diagnostics on the Princeton large torus (PLT), Princeton divertor experiment (PDX), and tokamak fusion test reactor (TFTR) tokamaks. The design parameters of these systems are compared. Particular attention is given to describing those new components and techniques which have contributed most to improved data quality and reliability in the ten-year evolution of these systems. Examples of recent TFTR Te(R) and ne(R) profiles are presented.

  7. Fourier domain design of microgrid imaging polarimeters with improved spatial resolution

    NASA Astrophysics Data System (ADS)

    Hirakawa, Keigo; LeMaster, Daniel A.

    2014-05-01

    Microgrid polarimetric imagers sacrifice spatial resolution for sensitivity to states of linear polarization. We have recently shown that a 2 × 4 microgrid analyzer pattern sacrifices less spatial resolution than the conventional 2× 2 case without compromising polarization sensitivity. In this paper, we discuss the design strategy that uncovered the spatial resolution benefits of the 2 × 4 array.

  8. A method of spatial mapping and reclassification for high-spatial-resolution remote sensing image classification.

    PubMed

    Wang, Guizhou; Liu, Jianbo; He, Guojin

    2013-01-01

    This paper presents a new classification method for high-spatial-resolution remote sensing images based on a strategic mechanism of spatial mapping and reclassification. The proposed method includes four steps. First, the multispectral image is classified by a traditional pixel-based classification method (support vector machine). Second, the panchromatic image is subdivided by watershed segmentation. Third, the pixel-based multispectral image classification result is mapped to the panchromatic segmentation result based on a spatial mapping mechanism and the area dominant principle. During the mapping process, an area proportion threshold is set, and the regional property is defined as unclassified if the maximum area proportion does not surpass the threshold. Finally, unclassified regions are reclassified based on spectral information using the minimum distance to mean algorithm. Experimental results show that the classification method for high-spatial-resolution remote sensing images based on the spatial mapping mechanism and reclassification strategy can make use of both panchromatic and multispectral information, integrate the pixel- and object-based classification methods, and improve classification accuracy.

  9. Spatial and temporal resolution of fluid flows: LDRD final report

    SciTech Connect

    Tieszen, S.R.; O`Hern, T.J.; Schefer, R.W.; Perea, L.D.

    1998-02-01

    This report describes a Laboratory Directed Research and Development (LDRD) activity to develop a diagnostic technique for simultaneous temporal and spatial resolution of fluid flows. The goal is to obtain two orders of magnitude resolution in two spatial dimensions and time simultaneously. The approach used in this study is to scale up Particle Image Velocimetry (PIV) and Planar Laser Induced Fluorescence (PLIF) to acquire meter-size images at up to 200 frames/sec. Experiments were conducted in buoyant, fully turbulent, non-reacting and reacting plumes with a base diameter of one meter. The PIV results were successful in the ambient gas for all flows, and in the plume for non-reacting helium and reacting methane, but not reacting hydrogen. No PIV was obtained in the hot combustion product region as the seed particles chosen vaporized. Weak signals prevented PLIF in the helium. However, in reacting methane flows, PLIF images speculated to be from Poly-Aromatic-Hydrocarbons were obtained which mark the flame sheets. The results were unexpected and very insightful. A natural fluorescence from the seed particle vapor was also noted in the hydrogen tests.

  10. Efficiency and spatial resolution of the CASCADE thermal neutron detector

    NASA Astrophysics Data System (ADS)

    Köhli, M.; Allmendinger, F.; Häußler, W.; Schröder, T.; Klein, M.; Meven, M.; Schmidt, U.

    2016-08-01

    We report on the CASCADE project - a detection system, which has been designed for the purposes of neutron Spin Echo spectroscopy and which is continuously further developed and adapted to various applications. It features 2D spatially resolved detection of thermal neutrons at high rates. The CASCADE detector is composed of a stack of solid 10B coated Gas Electron Multiplier foils, which serve both as a neutron converter and as an amplifier for the primary ionization deposited in the standard counting gas environment. This multi-layer setup efficiently increases the detection efficiency and by extracting the signal of the charge traversing the stack the conversion layer can be identified allowing a precise determination of the time-of-flight. The spatial resolution is found by optical contrast determination to be σ =(1.39 ± 0.05) mm and by divergence corrected aperture measurements σ =(1.454 ± 0.007) mm , which is in agreement with the simulated detector model. Furthermore this enabled to investigate and describe the non-Gaussian resolution function. At the HEiDi diffractometer the absolute detection efficiency has been studied. At 0.6 Å for the 6 layer detector, which is currently part of the RESEDA spectrometer, an efficiency of 7.8% has been measured, which by means of Monte Carlo simulations translates to (21.0±1.5)% for thermal neutrons at 1.8 Å and (46.9±3.3)% at 5.4 Å.

  11. Spatial Resolution Characterization for AWiFS Multispectral Images

    NASA Technical Reports Server (NTRS)

    Blonski, Slawomir; Ryan, Robert E.; Pagnutti, Mary; Stanley, Thomas

    2006-01-01

    Within the framework of the Joint Agency Commercial Imagery Evaluation program, the National Aeronautics and Space Administration, the National Geospatial-Intelligence Agency, and the U.S. Geological Survey cooperate in the characterization of high-to-moderate-resolution commercial imagery of mutual interest. One of the systems involved in this effort is the Advanced Wide Field Sensor (AWiFS) onboard the Indian Remote Sensing (IRS) Reourcesat-1 satellite, IRS-P6. Spatial resolution of the AWiFS multispectral images was characterized by estimating the value of the system Modulation Transfer Function (MTF) at the Nyquist spatial frequency. The Nyquist frequency is defined as half the sampling frequency, and the sampling frequency is equal to the inverse of the ground sample distance. The MTF was calculated as a ratio of the Fourier transform of a profile across an AWiFS image of the Lake Pontchartrain Causeway Bridge and the Fourier transform of a profile across an idealized model of the bridge for each spectral band evaluated. The mean MTF value for the AWiFS imagery evaluated was estimated to be 0.1.

  12. Trace metal imaging with high spatial resolution: applications in biomedicine.

    PubMed

    Qin, Zhenyu; Caruso, Joseph A; Lai, Barry; Matusch, Andreas; Becker, J Sabine

    2011-01-01

    New generations of analytical techniques for imaging of metals are pushing hitherto boundaries of spatial resolution and quantitative analysis in biology. Because of this, the application of these imaging techniques described herein to the study of the organization and dynamics of metal cations and metal-containing biomolecules in biological cell and tissue is becoming an important issue in biomedical research. In the current review, three common metal imaging techniques in biomedical research are introduced, including synchrotron X-ray fluorescence (SXRF) microscopy, secondary ion mass spectrometry (SIMS), and laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS). These are exemplified by a demonstration of the dopamine-Fe complexes, by assessment of boron distribution in a boron neutron capture therapy cell model, by mapping Cu and Zn in human brain cancer and a rat brain tumor model, and by the analysis of metal topography within neuromelanin. These studies have provided solid evidence that demonstrates that the sensitivity, spatial resolution, specificity, and quantification ability of metal imaging techniques is suitable and highly desirable for biomedical research. Moreover, these novel studies on the nanometre scale (e.g., of individual single cells or cell organelles) will lead to a better understanding of metal processes in cells and tissues.

  13. Role of color and spatial resolution in digital imaging colposcopy

    NASA Astrophysics Data System (ADS)

    Craine, Eric R.; Engel, John R.; Craine, Brian L.

    1990-07-01

    We have developed a practical digital imaging colposcope for use in research on early detection of cancerous and pre-cancerous tissue in the cervix. Several copies of the system have now been used in a variety of clinical and research environments. Two issues of considerable interest which emerged early in our work involved the roles of color and spatial resolution as they applied to digital imaging colposcopy. In each instance these qualities potentially have a significant impact on the diagnostic efficacy of the system. In order to evaluate the role of these parameters we devised and conducted a receiver operating characteristic (ROC) evaluation of the system. It is apparent from these tests that a spatial resolution of 512 x 480 pixel with 7 or 8 bits of contrast is adequate for the task. The more interesting result arises from the study of the use of color in these examinations; it appears that in general, contrary to the widely held perception of the physicians involved, color apparently provides the clinician with little or no diagnostic information. Indeed, in some instances, access to color seemed to confuse the physician and resulted in an elevated rate of false positives. Results of the ROC tests are presented in this paper along with their implications for further development of this imaging modality.

  14. Progress toward accurate high spatial resolution actinide analysis by EPMA

    NASA Astrophysics Data System (ADS)

    Jercinovic, M. J.; Allaz, J. M.; Williams, M. L.

    2010-12-01

    High precision, high spatial resolution EPMA of actinides is a significant issue for geochronology, resource geochemistry, and studies involving the nuclear fuel cycle. Particular interest focuses on understanding of the behavior of Th and U in the growth and breakdown reactions relevant to actinide-bearing phases (monazite, zircon, thorite, allanite, etc.), and geochemical fractionation processes involving Th and U in fluid interactions. Unfortunately, the measurement of minor and trace concentrations of U in the presence of major concentrations of Th and/or REEs is particularly problematic, especially in complexly zoned phases with large compositional variation on the micro or nanoscale - spatial resolutions now accessible with modern instruments. Sub-micron, high precision compositional analysis of minor components is feasible in very high Z phases where scattering is limited at lower kV (15kV or less) and where the beam diameter can be kept below 400nm at high current (e.g. 200-500nA). High collection efficiency spectrometers and high performance electron optics in EPMA now allow the use of lower overvoltage through an exceptional range in beam current, facilitating higher spatial resolution quantitative analysis. The U LIII edge at 17.2 kV precludes L-series analysis at low kV (high spatial resolution), requiring careful measurements of the actinide M series. Also, U-La detection (wavelength = 0.9A) requires the use of LiF (220) or (420), not generally available on most instruments. Strong peak overlaps of Th on U make highly accurate interference correction mandatory, with problems compounded by the ThMIV and ThMV absorption edges affecting peak, background, and interference calibration measurements (especially the interference of the Th M line family on UMb). Complex REE bearing phases such as monazite, zircon, and allanite have particularly complex interference issues due to multiple peak and background overlaps from elements present in the activation

  15. Spatial resolution effects on the assessment of evapotranspiration in olive orchards using high resolution thermal imagery

    NASA Astrophysics Data System (ADS)

    Santos, Cristina; Zarco-Tejada, Pablo J.; Lorite, Ignacio J.; Allen, Richard G.

    2013-04-01

    The use of remote sensing techniques for estimating surface energy balance and water consumption has significantly improved the characterization of the agricultural systems by determining accurate information about crop evapotranspiration and stress, mainly for extensive crops. However the use of these methodologies for woody crops has been low due to the difficulty in the accurate characterization of these crops, mainly caused by a coarse resolution of the imagery provided by the most widely used satellites (such as Landsat 5 and 7). The coarse spatial resolution provided by these satellite sensors aggregates into a single pixel the tree crown, sunlit and shaded soil components. These surfaces can each exhibit huge differences in temperature, albedo and vegetation indexes calculated in the visible, near infrared and short-wave infrared regions. Recent studies have found that the use of energy balance approaches can provide useful results for non-homogeneous crops (Santos et al., 2012) but detailed analysis is required to determine the effect of the spatial resolution and the aggregation of the scene components in these heterogeneous canopies. In this study a comparison between different spatial resolutions has been conducted using images from Landsat 7 (with thermal resolution of 60m) and from an airborne thermal (with resolution of 80 cm) flown over olive orchards at different dates coincident with the Landsat overpass. The high resolution thermal imagery was resampled at different scales to generate images with spatial resolution ranging from 0.8 m up to 120m (thermal resolution for Landsat 5 images). The selection of the study area was made to avoid those areas with missing Landsat 7 data caused by SLC-off gaps. The selected area has a total area of around 2500 ha and is located in Southern Spain, in the province of Malaga. The selected area is mainly cultivated with olive orchards with different crop practices (rainfed, irrigated, high density, young and adult

  16. COMPLEX ORGANIC MOLECULES AT HIGH SPATIAL RESOLUTION TOWARD ORION-KL. I. SPATIAL SCALES

    SciTech Connect

    Widicus Weaver, Susanna L.; Friedel, Douglas N. E-mail: friedel@astro.illinois.edu

    2012-08-01

    Here we present high spatial resolution (<1'') observations of molecular emission in Orion-KL conducted using the Combined Array for Research in Millimeter-wave Astronomy. This work was motivated by recent millimeter continuum imaging studies of this region conducted at a similarly high spatial resolution, which revealed that the bulk of the emission arises from numerous compact sources, rather than the larger-scale extended structures typically associated with the Orion Hot Core and Compact Ridge. Given that the spatial extent of molecular emission greatly affects the determination of molecular abundances, it is important to determine the true spatial scale for complex molecules in this region. Additionally, it has recently been suggested that the relative spatial distributions of complex molecules in a source might give insight into the chemical mechanisms that drive complex chemistry in star-forming regions. In order to begin to address these issues, this study seeks to determine the spatial distributions of ethyl cyanide [C{sub 2}H{sub 5}CN], dimethyl ether [(CH{sub 3}){sub 2}O], methyl formate [HCOOCH{sub 3}], formic acid [HCOOH], acetone [(CH{sub 3}){sub 2}CO], SiO, methanol [CH{sub 3}OH], and methyl cyanide [CH{sub 3}CN] in Orion-KL at {lambda} = 3 mm. We find that for all observed molecules, the molecular emission arises from multiple components of the cloud that include a range of spatial scales and physical conditions. Here, we present the results of these observations and discuss the implications for studies of complex molecules in star-forming regions.

  17. High Spatial Resolution Fe XII Observations of Solar Active Regions

    NASA Astrophysics Data System (ADS)

    Testa, Paola; De Pontieu, Bart; Hansteen, Viggo

    2016-08-01

    We use UV spectral observations of active regions with the Interface Region Imaging Spectrograph (IRIS) to investigate the properties of the coronal Fe xii 1349.4 Å emission at unprecedented high spatial resolution (˜0.33″). We find that by using appropriate observational strategies (i.e., long exposures, lossless compression), Fe xii emission can be studied with IRIS at high spatial and spectral resolution, at least for high-density plasma (e.g., post-flare loops and active region moss). We find that upper transition region (TR; moss) Fe xii emission shows very small average Doppler redshifts ({v}{{D}} ˜ 3 km s‑1) as well as modest non-thermal velocities (with an average of ˜24 km s‑1 and the peak of the distribution at ˜15 km s‑1). The observed distribution of Doppler shifts appears to be compatible with advanced three-dimensional radiative MHD simulations in which impulsive heating is concentrated at the TR footpoints of a hot corona. While the non-thermal broadening of Fe xii 1349.4 Å peaks at similar values as lower resolution simultaneous Hinode Extreme Ultraviolet Imaging Spectrometer (EIS) measurements of Fe xii 195 Å, IRIS observations show a previously undetected tail of increased non-thermal broadening that might be suggestive of the presence of subarcsecond heating events. We find that IRIS and EIS non-thermal line broadening measurements are affected by instrumental effects that can only be removed through careful analysis. Our results also reveal an unexplained discrepancy between observed 195.1/1349.4 Å Fe xii intensity ratios and those predicted by the CHIANTI atomic database.

  18. High Spatial Resolution Fe XII Observations of Solar Active Regions

    NASA Astrophysics Data System (ADS)

    Testa, Paola; De Pontieu, Bart; Hansteen, Viggo

    2016-08-01

    We use UV spectral observations of active regions with the Interface Region Imaging Spectrograph (IRIS) to investigate the properties of the coronal Fe xii 1349.4 Å emission at unprecedented high spatial resolution (˜0.33″). We find that by using appropriate observational strategies (i.e., long exposures, lossless compression), Fe xii emission can be studied with IRIS at high spatial and spectral resolution, at least for high-density plasma (e.g., post-flare loops and active region moss). We find that upper transition region (TR; moss) Fe xii emission shows very small average Doppler redshifts ({v}{{D}} ˜ 3 km s-1) as well as modest non-thermal velocities (with an average of ˜24 km s-1 and the peak of the distribution at ˜15 km s-1). The observed distribution of Doppler shifts appears to be compatible with advanced three-dimensional radiative MHD simulations in which impulsive heating is concentrated at the TR footpoints of a hot corona. While the non-thermal broadening of Fe xii 1349.4 Å peaks at similar values as lower resolution simultaneous Hinode Extreme Ultraviolet Imaging Spectrometer (EIS) measurements of Fe xii 195 Å, IRIS observations show a previously undetected tail of increased non-thermal broadening that might be suggestive of the presence of subarcsecond heating events. We find that IRIS and EIS non-thermal line broadening measurements are affected by instrumental effects that can only be removed through careful analysis. Our results also reveal an unexplained discrepancy between observed 195.1/1349.4 Å Fe xii intensity ratios and those predicted by the CHIANTI atomic database.

  19. High resolution autofocus for spatial temporal biomedical research

    NASA Astrophysics Data System (ADS)

    Li, Sihong; Cui, Xiaodong; Huang, Wei

    2013-11-01

    Maintaining focus has been a critical but challenging issue in optical microscopy, particularly for microscopic imaging systems currently used in biomedical research. During live cell imaging, environmental temperature fluctuations and other factors contribute to the unavoidable focus drift. For single molecular imaging and super resolution, focus drift can be significant even over short durations. The current commercial and experimental solutions are either optically complicated, expensive, or with limited axial resolution. Here, we present a simple autofocus solution based on low cost solid state laser and imaging sensor. By improving the optical train design and using real-time data analysis, improvement in axial resolution by approximately two orders of magnitudes over the focal depth of microscope objectives can be achieved. This solution has been tested for prolonged live cell imaging for fast ramping up in environmental chamber temperature and large daily swing in room temperature. In addition, this system can be used to spatial-temporally measure the surface for three-dimensional cell culture and tissue engineering, with flexibility that exceeds commercially available systems.

  20. Mapping Spatial Variability in Health and Wealth Indicators in Accra, Ghana Using High Spatial Resolution Imagery

    NASA Astrophysics Data System (ADS)

    Engstrom, R.; Ashcroft, E.

    2014-12-01

    There has been a tremendous amount of research conducted that examines disparities in health and wealth of persons between urban and rural areas however, relatively little research has been undertaken to examine variations within urban areas. A major limitation to elucidating differences with urban areas is the lack of social and demographic data at a sufficiently high spatial resolution to determine these differences. Generally the only available data that contain this information are census data which are collected at most every ten years and are often difficult to obtain at a high enough spatial resolution to allow for examining in depth variability in health and wealth indicators at high spatial resolutions, especially in developing countries. High spatial resolution satellite imagery may be able to provide timely and synoptic information that is related to health and wealth variability within a city. In this study we use two dates of Quickbird imagery (2003 and 2010) classified into the vegetation-impervious surface-soil (VIS) model introduced by Ridd (1995). For 2003 we only have partial coverage of the city, while for 2010 we have a mosaic, which covers the entire city of Accra, Ghana. Variations in the VIS values represent the physical variations within the city and these are compared to variations in economic, and/or sociodemographic data derived from the 2000 Ghanaian census at two spatial resolutions, the enumeration area (approximately US Census Tract) and the neighborhood for the city. Results indicate a significant correlation between both vegetation and impervious surface to type of cooking fuel used in the household, population density, housing density, availability of sewers, cooking space usage, and other variables. The correlations are generally stronger at the neighborhood level and the relationships are stable through time and space. Overall, the results indicate that information derived from high resolution satellite data is related to

  1. Spectral sensitivity, spatial resolution and temporal resolution and their implications for conspecific signalling in cleaner shrimp.

    PubMed

    Caves, Eleanor M; Frank, Tamara M; Johnsen, Sönke

    2016-02-01

    Cleaner shrimp (Decapoda) regularly interact with conspecifics and client reef fish, both of which appear colourful and finely patterned to human observers. However, whether cleaner shrimp can perceive the colour patterns of conspecifics and clients is unknown, because cleaner shrimp visual capabilities are unstudied. We quantified spectral sensitivity and temporal resolution using electroretinography (ERG), and spatial resolution using both morphological (inter-ommatidial angle) and behavioural (optomotor) methods in three cleaner shrimp species: Lysmata amboinensis, Ancylomenes pedersoni and Urocaridella antonbruunii. In all three species, we found strong evidence for only a single spectral sensitivity peak of (mean ± s.e.m.) 518 ± 5, 518 ± 2 and 533 ± 3 nm, respectively. Temporal resolution in dark-adapted eyes was 39 ± 1.3, 36 ± 0.6 and 34 ± 1.3 Hz. Spatial resolution was 9.9 ± 0.3, 8.3 ± 0.1 and 11 ± 0.5 deg, respectively, which is low compared with other compound eyes of similar size. Assuming monochromacy, we present approximations of cleaner shrimp perception of both conspecifics and clients, and show that cleaner shrimp visual capabilities are sufficient to detect the outlines of large stimuli, but not to detect the colour patterns of conspecifics or clients, even over short distances. Thus, conspecific viewers have probably not played a role in the evolution of cleaner shrimp appearance; rather, further studies should investigate whether cleaner shrimp colour patterns have evolved to be viewed by client reef fish, many of which possess tri- and tetra-chromatic colour vision and relatively high spatial acuity.

  2. Spectral sensitivity, spatial resolution and temporal resolution and their implications for conspecific signalling in cleaner shrimp.

    PubMed

    Caves, Eleanor M; Frank, Tamara M; Johnsen, Sönke

    2016-02-01

    Cleaner shrimp (Decapoda) regularly interact with conspecifics and client reef fish, both of which appear colourful and finely patterned to human observers. However, whether cleaner shrimp can perceive the colour patterns of conspecifics and clients is unknown, because cleaner shrimp visual capabilities are unstudied. We quantified spectral sensitivity and temporal resolution using electroretinography (ERG), and spatial resolution using both morphological (inter-ommatidial angle) and behavioural (optomotor) methods in three cleaner shrimp species: Lysmata amboinensis, Ancylomenes pedersoni and Urocaridella antonbruunii. In all three species, we found strong evidence for only a single spectral sensitivity peak of (mean ± s.e.m.) 518 ± 5, 518 ± 2 and 533 ± 3 nm, respectively. Temporal resolution in dark-adapted eyes was 39 ± 1.3, 36 ± 0.6 and 34 ± 1.3 Hz. Spatial resolution was 9.9 ± 0.3, 8.3 ± 0.1 and 11 ± 0.5 deg, respectively, which is low compared with other compound eyes of similar size. Assuming monochromacy, we present approximations of cleaner shrimp perception of both conspecifics and clients, and show that cleaner shrimp visual capabilities are sufficient to detect the outlines of large stimuli, but not to detect the colour patterns of conspecifics or clients, even over short distances. Thus, conspecific viewers have probably not played a role in the evolution of cleaner shrimp appearance; rather, further studies should investigate whether cleaner shrimp colour patterns have evolved to be viewed by client reef fish, many of which possess tri- and tetra-chromatic colour vision and relatively high spatial acuity. PMID:26747903

  3. Full-field spatially incoherent illumination interferometry: a spatial resolution almost insensitive to aberrations.

    PubMed

    Xiao, Peng; Fink, Mathias; Boccara, A Claude

    2016-09-01

    We show that with spatially incoherent illumination, the point spread function (PSF) width/spatial resolution of an imaging interferometer like that used in full-field optical coherence tomography (OCT) is almost insensitive to aberrations. In these systems, aberrations mostly induce a reduction of the signal level that leads to a loss of the signal-to-noise ratio without broadening the system PSF. This is demonstrated by comparison with traditional scanning OCT and wide-field OCT with spatially coherent illuminations. Theoretical analysis and numerical calculation as well as experimental results are provided to show this specific merit of incoherent illumination in full-field OCT. To the best of our knowledge, this is the first time that such a result has been demonstrated. PMID:27607937

  4. Tactile feedback display with spatial and temporal resolutions.

    PubMed

    Vishniakou, Siarhei; Lewis, Brian W; Niu, Xiaofan; Kargar, Alireza; Sun, Ke; Kalajian, Michael; Park, Namseok; Yang, Muchuan; Jing, Yi; Brochu, Paul; Sun, Zhelin; Li, Chun; Nguyen, Truong; Pei, Qibing; Wang, Deli

    2013-01-01

    We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage. The ability to record, store, edit, and replay touch information adds an additional dimension to digital technologies and extends the capabilities of modern information exchange with the potential to revolutionize physical learning, social networking, e-commerce, robotics, gaming, medical and military applications. PMID:23982053

  5. Tactile Feedback Display with Spatial and Temporal Resolutions

    NASA Astrophysics Data System (ADS)

    Vishniakou, Siarhei; Lewis, Brian W.; Niu, Xiaofan; Kargar, Alireza; Sun, Ke; Kalajian, Michael; Park, Namseok; Yang, Muchuan; Jing, Yi; Brochu, Paul; Sun, Zhelin; Li, Chun; Nguyen, Truong; Pei, Qibing; Wang, Deli

    2013-08-01

    We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage. The ability to record, store, edit, and replay touch information adds an additional dimension to digital technologies and extends the capabilities of modern information exchange with the potential to revolutionize physical learning, social networking, e-commerce, robotics, gaming, medical and military applications.

  6. Tactile Feedback Display with Spatial and Temporal Resolutions

    PubMed Central

    Vishniakou, Siarhei; Lewis, Brian W.; Niu, Xiaofan; Kargar, Alireza; Sun, Ke; Kalajian, Michael; Park, Namseok; Yang, Muchuan; Jing, Yi; Brochu, Paul; Sun, Zhelin; Li, Chun; Nguyen, Truong; Pei, Qibing; Wang, Deli

    2013-01-01

    We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage. The ability to record, store, edit, and replay touch information adds an additional dimension to digital technologies and extends the capabilities of modern information exchange with the potential to revolutionize physical learning, social networking, e-commerce, robotics, gaming, medical and military applications. PMID:23982053

  7. High spatial resolution infrared camera as ISS external experiment

    NASA Astrophysics Data System (ADS)

    Eckehard, Lorenz; Frerker, Hap; Fitch, Robert Alan

    High spatial resolution infrared camera as ISS external experiment for monitoring global climate changes uses ISS internal and external resources (eg. data storage). The optical experiment will consist of an infrared camera for monitoring global climate changes from the ISS. This technology was evaluated by the German small satellite mission BIRD and further developed in different ESA projects. Compared to BIRD the presended instrument uses proven sensor advanced technologies (ISS external) and ISS on board processing and storage capabili-ties (internal). The instrument will be equipped with a serial interfaces for TM/TC and several relay commands for the power supply. For data processing and storage a mass memory is re-quired. The access to actual attitude data is highly desired to produce geo referenced maps-if possible by an on board processing.

  8. Tactile feedback display with spatial and temporal resolutions.

    PubMed

    Vishniakou, Siarhei; Lewis, Brian W; Niu, Xiaofan; Kargar, Alireza; Sun, Ke; Kalajian, Michael; Park, Namseok; Yang, Muchuan; Jing, Yi; Brochu, Paul; Sun, Zhelin; Li, Chun; Nguyen, Truong; Pei, Qibing; Wang, Deli

    2013-01-01

    We report the electronic recording of the touch contact and pressure using an active matrix pressure sensor array made of transparent zinc oxide thin-film transistors and tactile feedback display using an array of diaphragm actuators made of an interpenetrating polymer elastomer network. Digital replay, editing and manipulation of the recorded touch events were demonstrated with both spatial and temporal resolutions. Analog reproduction of the force is also shown possible using the polymer actuators, despite of the high driving voltage. The ability to record, store, edit, and replay touch information adds an additional dimension to digital technologies and extends the capabilities of modern information exchange with the potential to revolutionize physical learning, social networking, e-commerce, robotics, gaming, medical and military applications.

  9. Elemental Analysis of Glass Optical Fibres with High Spatial Resolution.

    NASA Astrophysics Data System (ADS)

    Pugh, Andrew

    Available from UMI in association with The British Library. The properties of glass optical fibres are very strongly dependent on the elemental concentration profiles of the fibre cores. Core dopants such as germanium define the core refractive index, which in turn defines the manner in which the light is transmitted through the fibre. Erbium in fibre cores can facilitate the operation of fibre lasers and aluminium in turn can control the erbium distribution. The aim of the project described in this thesis was to measure the elemental concentration profiles in a variety of fibre cores using X-ray microanalysis in an electron microscope. Conventional X-ray microanalysis of bulk samples has an analytical resolution in the order of a micron. With monomode optical fibre cores having cores typically three microns in diameter the resolution of the conventional technique is plainly inadequate. An experimental technique has been developed for the preparation of thin cross-sectional samples of glass optical fibres. Application of this technique has facilitated the preparation and analysis of thin film specimens with an average thickness of 400 microns. This approach has allowed analysis to be performed with an effective spatial resolution of 100-300 nm. The technique has been applied to the determination of germanium concentration in Raman fibres, to the investigation of erbium confinement in erbium doped fibres and to the investigation of inter-ionic diffusion in semiconductor doped fibres. It has been shown that the germanium, and hence refractive index, profile of germanium doped fibres is not changed by the process of fibre drawing. Evidence has been gathered supporting the theory of erbium confinement by aluminium and an important degree of elemental diffusion has been shown to take place during the drawing of semiconductor doped fibres. In addition an experimental technique has been developed for the preparation of thin cross-sectional samples of glass optical fibres.

  10. Development of an Objective High Spatial Resolution Soil Moisture Index

    NASA Astrophysics Data System (ADS)

    Zavodsky, B.; Case, J.; White, K.; Bell, J. R.

    2015-12-01

    Drought detection, analysis, and mitigation has become a key challenge for a diverse set of decision makers, including but not limited to operational weather forecasters, climatologists, agricultural interests, and water resource management. One tool that is heavily used is the United States Drought Monitor (USDM), which is derived from a complex blend of objective data and subjective analysis on a state-by-state basis using a variety of modeled and observed precipitation, soil moisture, hydrologic, and vegetation and crop health data. The NASA Short-term Prediction Research and Transition (SPoRT) Center currently runs a real-time configuration of the Noah land surface model (LSM) within the NASA Land Information System (LIS) framework. The LIS-Noah is run at 3-km resolution for local numerical weather prediction (NWP) and situational awareness applications at select NOAA/National Weather Service (NWS) forecast offices over the Continental U.S. (CONUS). To enhance the practicality of the LIS-Noah output for drought monitoring and assessing flood potential, a 30+-year soil moisture climatology has been developed in an attempt to place near real-time soil moisture values in historical context at county- and/or watershed-scale resolutions. This LIS-Noah soil moisture climatology and accompanying anomalies is intended to complement the current suite of operational products, such as the North American Land Data Assimilation System phase 2 (NLDAS-2), which are generated on a coarser-resolution grid that may not capture localized, yet important soil moisture features. Daily soil moisture histograms are used to identify the real-time soil moisture percentiles at each grid point according to the county or watershed in which the grid point resides. Spatial plots are then produced that map the percentiles as proxies to the different USDM categories. This presentation will highlight recent developments of this gridded, objective soil moisture index, comparison to subjective

  11. Forest Classification Accuracy as Influenced by Multispectral Scanner Spatial Resolution. [Sam Houston National Forest, Texas

    NASA Technical Reports Server (NTRS)

    Nalepka, R. F. (Principal Investigator); Sadowski, F. E.; Sarno, J. E.

    1976-01-01

    The author has identified the following significant results. A supervised classification within two separate ground areas of the Sam Houston National Forest was carried out for two sq meters spatial resolution MSS data. Data were progressively coarsened to simulate five additional cases of spatial resolution ranging up to 64 sq meters. Similar processing and analysis of all spatial resolutions enabled evaluations of the effect of spatial resolution on classification accuracy for various levels of detail and the effects on area proportion estimation for very general forest features. For very coarse resolutions, a subset of spectral channels which simulated the proposed thematic mapper channels was used to study classification accuracy.

  12. High spatial resolution image restoration from subpixel-shifted hyperspectral images

    NASA Astrophysics Data System (ADS)

    Su, Lijuan; Zhou, Shubo; Yuan, Yan

    2015-01-01

    The spatial resolution of hyperspectral imaging systems is constrained by a spatial-spectral resolution tradeoff and current technique limitations. However, spatial resolution is a critical feature for applications that require high spatial resolution and utilization of details. We present a method of restoring high-resolution (HR) images from a set of low-resolution (LR) hyperspectral data cubes with subpixel shifts across different bands. A new observation model is introduced to demonstrate LR hyperspectral images at different bands and an HR image that covers all these bands. A regularized super-resolution (SR) algorithm is then implemented to solve the problem. Experiments of the proposed algorithm and existing SR algorithms are performed and the results are evaluated. The results demonstrate the feasibility of the proposed SR method. Moreover, the image fusion results also demonstrate that the restored image is suitable for enhancing the spatial resolution of entire hyperspectral data cubes.

  13. Device for high spatial resolution chemical analysis of a sample and method of high spatial resolution chemical analysis

    DOEpatents

    Van Berkel, Gary J.

    2015-10-06

    A system and method for analyzing a chemical composition of a specimen are described. The system can include at least one pin; a sampling device configured to contact a liquid with a specimen on the at least one pin to form a testing solution; and a stepper mechanism configured to move the at least one pin and the sampling device relative to one another. The system can also include an analytical instrument for determining a chemical composition of the specimen from the testing solution. In particular, the systems and methods described herein enable chemical analysis of specimens, such as tissue, to be evaluated in a manner that the spatial-resolution is limited by the size of the pins used to obtain tissue samples, not the size of the sampling device used to solubilize the samples coupled to the pins.

  14. 1.1 mm Observations of the MBM12 Molecular Cloud

    NASA Astrophysics Data System (ADS)

    Kim, Sungeun; Kim, M.; Youn, S.; Yun, M. S.; Wilson, G. W.; Aretxaga, I.; Williams, J. P.; Hughes, D. H.; Humphrey, A.; Austermann, J. E.; Perera, T. A.; Mauskopf, P. D.; Magnani, L.

    2012-05-01

    We present 1.1 mm observations of the dust continuum emission from the MBM12 high-latitude molecular cloud observed with the Astronomical Thermal Emission Camera (AzTEC) mounted on the James Clerk Maxwell Telescope (JCMT) on Mauna Kea, Hawaii. Eight secure individual sources were detected with over 4.4 signal-to-noise ratio. These eight AzTEC sources can be considered to be real astronomical objects compared to the other candidates based on calculations of the false detection rate (FDR). The distribution of the detected 1.1 mm sources or compact 1.1 mm peaks is spatially anti-correlated with that of the 100 microm emission and the CO emission. We detected the 1.1 mm dust continuum emitting sources associated with two classical T Tauri stars, LkHalpha 262 and LkHalpha 264. Observations of spectral energy distributions (SEDs) indicate that LkHalpha 262 is likely to be Class II (pre-main sequence star), but there are also indications that it could be a late Class I (protostar). A flared disk and a bipolar cavity in the models of Class I sources lead to more complicated SEDs. From the present AzTEC observations of the MBM12 region, it appears that other sources detected with AzTEC are likely to be extragalactic and located behind MBM12. Some of these have radio counterparts and their star-formation rates (SFRs) are derived from a fit of the SEDs to the photometric evolution of galaxies in which the effects of a dusty interstellar medium have been included. This research was supported in part by Mid-career Researcher Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education, Science and Technology 2011-0028001.

  15. AzTEC 1.1 mm OBSERVATIONS OF THE MBM12 MOLECULAR CLOUD

    SciTech Connect

    Kim, M. J.; Kim, S.; Youn, S.; Kang, Y.-W.; Yun, M. S.; Wilson, G. W.; Aretxaga, I.; Hughes, D. H.; Humphrey, A.; Williams, J. P.; Austermann, J. E.; Perera, T. A.; Mauskopf, P. D.; Magnani, L.

    2012-02-10

    We present 1.1 mm observations of the dust continuum emission from the MBM12 high-latitude molecular cloud observed with the Astronomical Thermal Emission Camera (AzTEC) mounted on the James Clerk Maxwell Telescope on Mauna Kea, Hawaii. We surveyed 6.34 deg{sup 2} centered on MBM12, making this the largest area that has ever been surveyed in this region with submillimeter and millimeter telescopes. Eight secure individual sources were detected with a signal-to-noise ratio of over 4.4. These eight AzTEC sources can be considered to be real astronomical objects compared to the other candidates based on calculations of the false detection rate. The distribution of the detected 1.1 mm sources or compact 1.1 mm peaks is spatially anti-correlated with that of the 100 {mu}m emission and the {sup 12}CO emission. We detected the 1.1 mm dust continuum emitting sources associated with two classical T Tauri stars, LkH{alpha}262 and LkH{alpha}264. Observations of spectral energy distributions (SEDs) indicate that LkH{alpha}262 is likely to be Class II (pre-main-sequence star), but there are also indications that it could be a late Class I (protostar). A flared disk and a bipolar cavity in the models of Class I sources lead to more complicated SEDs. From the present AzTEC observations of the MBM12 region, it appears that other sources detected with AzTEC are likely to be extragalactic and located behind MBM12. Some of these have radio counterparts and their star formation rates are derived from a fit of the SEDs to the photometric evolution of galaxies in which the effects of a dusty interstellar medium have been included.

  16. High spatial and temporal resolution studies of ferroelectric thin films

    NASA Astrophysics Data System (ADS)

    Hubert, Charles Rankin, Jr.

    The subject of this thesis is the investigation of the polar structure and dynamics of ferroelectric thin films using newly developed high resolution optical, scanning- force microscopy and time-resolved methods. A technique based on confocal scanning optical microscopy (CSOM) is used to image the ferroelectric polarization of BaxSr1-xTiO 3 (BST) thin films at room temperature with sub-micron spatial resolution. Films of both paraelectric (x = 0.5) and ferroelectric ( x = 0.8) compositions show a coexistence of both paraelectric and ferroelectric phases on the smallest scale resolvable with this technique. These results suggest that non-uniform stress is responsible for the strong inhomogeneous thermal broadening of the ferroelectric phase transition, and that dielectric loss in thin films may be dominated by a relatively small fraction of nanometer-sized regions. Apertureless near-field scanning optical microscopy (ANSOM) is used to map the inhomogeneous ferroelectric polarization in BaxSr 1-xTiO3 thin films. Images of nanometer-scale ferroelectric domains in BaxSr1-xTiO3 thin films are obtained with 30 Å spatial resolution using ANSOM. The images exhibit inhomogeneities in the ferroelectric polarization over the smallest scales that can be observed, and are largely uncorrelated with topographic features. The application of an in-plane static electric field causes domain reorientation and domain-wall motion over distances as small as 40 Å. These results demonstrate the promise of ANSOM for imaging near-atomic-scale polarization fluctuations in ferroelectric materials. Interferometric ANSOM is described in detail, including a practical description of how ANSOM images are acquired. A discussion of the various contrast mechanisms in ANSOM is followed by a prescription for eliminating a certain class of topographic artifacts. For the imaging of polarization in ferroelectric thin films, the linear electro-optic effect provides the central contrast mechanism. High-resolution

  17. Continuum observations of M 51 and M 83 at 1.1 mm with AzTEC

    NASA Astrophysics Data System (ADS)

    Wall, W. F.; Puerari, I.; Tilanus, R.; Israel, F. P.; Austermann, J. E.; Aretxaga, I.; Wilson, G.; Yun, M.; Scott, K. S.; Perera, T. A.; Roberts, C. M.; Hughes, D. H.

    2016-06-01

    We observed the spiral galaxies M 51 and M 83 at 20 arscec spatial resolution with the bolometer array Aztronomical Thermal Emission Camera (AzTEC) on the JCMT in the 1.1 mm continuum, recovering the extended emission out to galactocentric radii of more than 12 kpc in both galaxies. The 1.1 mm-continuum fluxes are 5.6 ± 0.7 and 9.9 ± 1.4 Jy, with associated gas masses estimated at 9.4 × 109 M⊙ and 7.2 × 109 M⊙ for M 51 and M 83, respectively. In the interarm regions of both galaxies, the N(H2)/I(CO) (or X-factor) ratios exceed those in the arms by factors of ˜1.5-2. In the inner discs of both galaxies, the X-factor is about 1 × 1020 cm- 2 (K km s- 1)- 1. In the outer parts, the CO-dark molecular gas becomes more important. While the spiral density wave in M 51 appears to influence the interstellar medium and stars in a similar way, the bar potential in M 83 influences the interstellar medium and the stars differently. We confirm the result of Foyle et al. that the arms merely heighten the star formation rate (SFR) and the gas surface density in the same proportion. Our maps reveal a threshold gas surface density for an SFR increase by two or more orders of magnitude. In both galaxy centres, the molecular gas depletion time is about 1 Gyr climbing to 10-20 Gyr at radii of 6-8 kpc. This is consistent with an inside-out depletion of the molecular gas in the discs of spiral galaxies.

  18. Estimating Regional Changes in Soil Carbon with High Spatial Resolution

    SciTech Connect

    West, Tristram O.; Brandt, Craig C; Marland, Gregg; De La Torre Ugarte, Daniel G; Larson, James; Hellwinckel, Chad M; Wilson, Bradly; Tyler, Donald G; Nelson, Richard G

    2008-01-01

    To manage lands locally for carbon sequestration and for emissions reductions it is useful to have a system that can monitor and predict changes in soil carbon and greenhouse gas emissions with high spatial resolution. We are developing a carbon accounting framework that can estimate carbon dynamics and net emissions associated with changes in land management. One component of this framework integrates field measurements, inventory data, and remote sensing products to estimate changes in soil carbon and to estimate where these changes are likely to occur at a sub-county (30m x 30m) resolution. We applied this framework component to a mid-western region of the US that consists of 679 counties approximately centered around Iowa. We estimate the 1990 baseline soil carbon to a maximum depth of 3m for this region to be 4,117 Tg C. Cumulative soil carbon accumulation of 70.3 Tg C is estimated for this region between 1991-2000, of which 33.8 Tg C is due to changes in tillage intensity. Without accounting for soil carbon loss following changes to more intensive tillage practices, our estimate increases to 45.0 Tg C. This difference indicates that on-site permanence of soil carbon associated with a change to less intensive tillage practices is approximately 75% if no additional economic incentives are provided for soil carbon sequestration practices. This carbon accounting framework offers a method to integrate inventory and remote sensing data on an annual basis and to transparently account for alternating annual trends in land management and associated carbon stocks and fluxes.

  19. Methods of photoelectrode characterization with high spatial and temporal resolution

    DOE PAGES

    Esposito, Daniel V.; Baxter, Jason B.; John, Jimmy; Lewis, Nathan S.; Moffat, Thomas P.; Ogitsu, Tadashi; O'Neil, Glen D.; Pham, Tuan Anh; Talin, A. Alec; Velazquez, Jesus M.; et al

    2015-06-19

    Here, materials and photoelectrode architectures that are highly efficient, extremely stable, and made from low cost materials are required for commercially viable photoelectrochemical (PEC) water-splitting technology. A key challenge is the heterogeneous nature of real-world materials, which often possess spatial variation in their crystal structure, morphology, and/or composition at the nano-, micro-, or macro-scale. Different structures and compositions can have vastly different properties and can therefore strongly influence the overall performance of the photoelectrode through complex structure–property relationships. A complete understanding of photoelectrode materials would also involve elucidation of processes such as carrier collection and electrochemical charge transfer that occurmore » at very fast time scales. We present herein an overview of a broad suite of experimental and computational tools that can be used to define the structure–property relationships of photoelectrode materials at small dimensions and on fast time scales. A major focus is on in situ scanning-probe measurement (SPM) techniques that possess the ability to measure differences in optical, electronic, catalytic, and physical properties with nano- or micro-scale spatial resolution. In situ ultrafast spectroscopic techniques, used to probe carrier dynamics involved with processes such as carrier generation, recombination, and interfacial charge transport, are also discussed. Complementing all of these experimental techniques are computational atomistic modeling tools, which can be invaluable for interpreting experimental results, aiding in materials discovery, and interrogating PEC processes at length and time scales not currently accessible by experiment. In addition to reviewing the basic capabilities of these experimental and computational techniques, we highlight key opportunities and limitations of applying these tools for the development of PEC materials.« less

  20. Methods of photoelectrode characterization with high spatial and temporal resolution

    SciTech Connect

    Esposito, Daniel V.; Baxter, Jason B.; John, Jimmy; Lewis, Nathan S.; Moffat, Thomas P.; Ogitsu, Tadashi; O'Neil, Glen D.; Pham, Tuan Anh; Talin, A. Alec; Velazquez, Jesus M.; Wood, Brandon C.

    2015-06-19

    Here, materials and photoelectrode architectures that are highly efficient, extremely stable, and made from low cost materials are required for commercially viable photoelectrochemical (PEC) water-splitting technology. A key challenge is the heterogeneous nature of real-world materials, which often possess spatial variation in their crystal structure, morphology, and/or composition at the nano-, micro-, or macro-scale. Different structures and compositions can have vastly different properties and can therefore strongly influence the overall performance of the photoelectrode through complex structure–property relationships. A complete understanding of photoelectrode materials would also involve elucidation of processes such as carrier collection and electrochemical charge transfer that occur at very fast time scales. We present herein an overview of a broad suite of experimental and computational tools that can be used to define the structure–property relationships of photoelectrode materials at small dimensions and on fast time scales. A major focus is on in situ scanning-probe measurement (SPM) techniques that possess the ability to measure differences in optical, electronic, catalytic, and physical properties with nano- or micro-scale spatial resolution. In situ ultrafast spectroscopic techniques, used to probe carrier dynamics involved with processes such as carrier generation, recombination, and interfacial charge transport, are also discussed. Complementing all of these experimental techniques are computational atomistic modeling tools, which can be invaluable for interpreting experimental results, aiding in materials discovery, and interrogating PEC processes at length and time scales not currently accessible by experiment. In addition to reviewing the basic capabilities of these experimental and computational techniques, we highlight key opportunities and limitations of applying these tools for the development of PEC materials.

  1. Visualization of microvascularity in glioblastoma multiforme with 8-T high-spatial-resolution MR imaging.

    PubMed

    Christoforidis, Gregory A; Grecula, John C; Newton, Herbert B; Kangarlu, Allahyar; Abduljalil, Amir M; Schmalbrock, Petra; Chakeres, Donald W

    2002-10-01

    We used 8-T high-spatial-resolution gradient-echo MR imaging to directly visualize microvascularity in pathologically proved glioblastoma multiforme. Images were compared with 1.5-T high-spatial-resolution fast spin-echo T2-weighted images and digital subtraction angiograms. Preliminary data indicate that 8-T high-spatial-resolution MR imaging may enable the identification of areas of abnormal microvascularity in glioblastoma multiforme that are not visible with other routine clinical techniques.

  2. Analysis of the impact of spatial resolution on land/water classifications using high-resolution aerial imagery

    USGS Publications Warehouse

    Enwright, Nicholas M.; Jones, William R.; Garber, Adrienne L.; Keller, Matthew J.

    2014-01-01

    Long-term monitoring efforts often use remote sensing to track trends in habitat or landscape conditions over time. To most appropriately compare observations over time, long-term monitoring efforts strive for consistency in methods. Thus, advances and changes in technology over time can present a challenge. For instance, modern camera technology has led to an increasing availability of very high-resolution imagery (i.e. submetre and metre) and a shift from analogue to digital photography. While numerous studies have shown that image resolution can impact the accuracy of classifications, most of these studies have focused on the impacts of comparing spatial resolution changes greater than 2 m. Thus, a knowledge gap exists on the impacts of minor changes in spatial resolution (i.e. submetre to about 1.5 m) in very high-resolution aerial imagery (i.e. 2 m resolution or less). This study compared the impact of spatial resolution on land/water classifications of an area dominated by coastal marsh vegetation in Louisiana, USA, using 1:12,000 scale colour-infrared analogue aerial photography (AAP) scanned at four different dot-per-inch resolutions simulating ground sample distances (GSDs) of 0.33, 0.54, 1, and 2 m. Analysis of the impact of spatial resolution on land/water classifications was conducted by exploring various spatial aspects of the classifications including density of waterbodies and frequency distributions in waterbody sizes. This study found that a small-magnitude change (1–1.5 m) in spatial resolution had little to no impact on the amount of water classified (i.e. percentage mapped was less than 1.5%), but had a significant impact on the mapping of very small waterbodies (i.e. waterbodies ≤ 250 m2). These findings should interest those using temporal image classifications derived from very high-resolution aerial photography as a component of long-term monitoring programs.

  3. Simulation of LANDSAT multispectral scanner spatial resolution with airborne scanner data

    NASA Technical Reports Server (NTRS)

    Hlavka, C. A.

    1986-01-01

    A technique for simulation of low spatial resolution satellite imagery by using high resolution scanner data is described. The scanner data is convolved with the approximate point spread function of the low resolution data and then resampled to emulate low resolution imagery. The technique was successfully applied to Daedalus airborne scanner data to simulate a portion of a LANDSAT multispectra scanner scene.

  4. Monte Carlo code for high spatial resolution ocean color simulations.

    PubMed

    D'Alimonte, Davide; Zibordi, Giuseppe; Kajiyama, Tamito; Cunha, José C

    2010-09-10

    A Monte Carlo code for ocean color simulations has been developed to model in-water radiometric fields of downward and upward irradiance (E(d) and E(u)), and upwelling radiance (L(u)) in a two-dimensional domain with a high spatial resolution. The efficiency of the code has been optimized by applying state-of-the-art computing solutions, while the accuracy of simulation results has been quantified through benchmark with the widely used Hydrolight code for various values of seawater inherent optical properties and different illumination conditions. Considering a seawater single scattering albedo of 0.9, as well as surface waves of 5 m width and 0.5 m height, the study has shown that the number of photons required to quantify uncertainties induced by wave focusing effects on E(d), E(u), and L(u) data products is of the order of 10(6), 10(9), and 10(10), respectively. On this basis, the effects of sea-surface geometries on radiometric quantities have been investigated for different surface gravity waves. Data products from simulated radiometric profiles have finally been analyzed as a function of the deployment speed and sampling frequency of current free-fall systems in view of providing recommendations to improve measurement protocols.

  5. An evaluation of the spatial resolution of soil moisture information

    NASA Technical Reports Server (NTRS)

    Hardy, K. R.; Cohen, S. H.; Rogers, L. K.; Burke, H. H. K.; Leupold, R. C.; Smallwood, M. D.

    1981-01-01

    Rainfall-amount patterns in the central regions of the U.S. were assessed. The spatial scales of surface features and their corresponding microwave responses in the mid western U.S. were investigated. The usefulness for U.S. government agencies of soil moisture information at scales of 10 km and 1 km. was ascertained. From an investigation of 494 storms, it was found that the rainfall resulting from the passage of most types of storms produces patterns which can be resolved on a 10 km scale. The land features causing the greatest problem in the sensing of soil moisture over large agricultural areas with a radiometer are bodies of water. Over the mid-western portions of the U.S., water occupies less than 2% of the total area, the consequently, the water bodies will not have a significant impact on the mapping of soil moisture. Over most of the areas, measurements at a 10-km resolution would adequately define the distribution of soil moisture. Crop yield models and hydrological models would give improved results if soil moisture information at scales of 10 km was available.

  6. Monte Carlo code for high spatial resolution ocean color simulations.

    PubMed

    D'Alimonte, Davide; Zibordi, Giuseppe; Kajiyama, Tamito; Cunha, José C

    2010-09-10

    A Monte Carlo code for ocean color simulations has been developed to model in-water radiometric fields of downward and upward irradiance (E(d) and E(u)), and upwelling radiance (L(u)) in a two-dimensional domain with a high spatial resolution. The efficiency of the code has been optimized by applying state-of-the-art computing solutions, while the accuracy of simulation results has been quantified through benchmark with the widely used Hydrolight code for various values of seawater inherent optical properties and different illumination conditions. Considering a seawater single scattering albedo of 0.9, as well as surface waves of 5 m width and 0.5 m height, the study has shown that the number of photons required to quantify uncertainties induced by wave focusing effects on E(d), E(u), and L(u) data products is of the order of 10(6), 10(9), and 10(10), respectively. On this basis, the effects of sea-surface geometries on radiometric quantities have been investigated for different surface gravity waves. Data products from simulated radiometric profiles have finally been analyzed as a function of the deployment speed and sampling frequency of current free-fall systems in view of providing recommendations to improve measurement protocols. PMID:20830183

  7. High spatial resolution spectrometry of rafting macroalgae (Sargassum)

    NASA Astrophysics Data System (ADS)

    Szekielda, Karl H.; Marmorino, George O.; Bowles, Jeffrey H.; Gillis, David

    2010-04-01

    Data with 0.4-m spatial resolution acquired ~2 km off the southeast Florida coast using the airborne Portable Hyperspectral Imager for Low-Light Spectroscopy (PHILLS) have been analyzed with the objective of identifying drifting surface macroalgae (Sargassum) through its spectral signature in at-sensor radiance. The observed spectral features of Sargassum include a peak at a wavelength of ~0.570 μm and a photosynthetic 'red edge' between 0.673 and 0.699 μm. Sargassum also exhibits high radiance in the reflected near-infrared but is impacted by the atmospheric absorption bands of water vapor at 0.720 μm and oxygen at 0.756 μm. The spectral signature is clearest and largest in amplitude where the Sargassum occurs as small surface aggregations, or rafts, which tend to lie at the downwind ends of narrow Sargassum windrows. The quantity of floating Sargassum was estimated within a single pixel by linearly mixing a spectrum of Sargassum-free water with varying percentages of a spectrum from a pixel assumed completely filled with floating plants. For our study site about 2.3% of the ocean area is classified as having some Sargassum coverage, with pixels completely filled with Sargassum being rare (only 0.2% of the classified Sargassum pixels) and pixels with the least-resolvable amount of Sargassum (~10% filled) being the most common.

  8. Thematic and spatial resolutions affect model-based predictions of tree species distribution.

    PubMed

    Liang, Yu; He, Hong S; Fraser, Jacob S; Wu, ZhiWei

    2013-01-01

    Subjective decisions of thematic and spatial resolutions in characterizing environmental heterogeneity may affect the characterizations of spatial pattern and the simulation of occurrence and rate of ecological processes, and in turn, model-based tree species distribution. Thus, this study quantified the importance of thematic and spatial resolutions, and their interaction in predictions of tree species distribution (quantified by species abundance). We investigated how model-predicted species abundances changed and whether tree species with different ecological traits (e.g., seed dispersal distance, competitive capacity) had different responses to varying thematic and spatial resolutions. We used the LANDIS forest landscape model to predict tree species distribution at the landscape scale and designed a series of scenarios with different thematic (different numbers of land types) and spatial resolutions combinations, and then statistically examined the differences of species abundance among these scenarios. Results showed that both thematic and spatial resolutions affected model-based predictions of species distribution, but thematic resolution had a greater effect. Species ecological traits affected the predictions. For species with moderate dispersal distance and relatively abundant seed sources, predicted abundance increased as thematic resolution increased. However, for species with long seeding distance or high shade tolerance, thematic resolution had an inverse effect on predicted abundance. When seed sources and dispersal distance were not limiting, the predicted species abundance increased with spatial resolution and vice versa. Results from this study may provide insights into the choice of thematic and spatial resolutions for model-based predictions of tree species distribution.

  9. MOSFET dosimetry with high spatial resolution in intense synchrotron-generated x-ray microbeams

    SciTech Connect

    Siegbahn, E. A.; Braeuer-Krisch, E.; Bravin, A.; Nettelbeck, H.; Lerch, M. L. F.; Rosenfeld, A. B.

    2009-04-15

    Various dosimeters have been tested for assessing absorbed doses with microscopic spatial resolution in targets irradiated by high-flux, synchrotron-generated, low-energy ({approx}30-300 keV) x-ray microbeams. A MOSFET detector has been used for this study since its radio sensitive element, which is extraordinarily narrow ({approx}1 {mu}m), suits the main applications of interest, microbeam radiation biology and microbeam radiation therapy (MRT). In MRT, micrometer-wide, centimeter-high, and vertically oriented swaths of tissue are irradiated by arrays of rectangular x-ray microbeams produced by a multislit collimator (MSC). We used MOSFETs to measure the dose distribution, produced by arrays of x-ray microbeams shaped by two different MSCs, in a tissue-equivalent phantom. Doses were measured near the center of the arrays and maximum/minimum (peak/valley) dose ratios (PVDRs) were calculated to determine how variations in heights and in widths of the microbeams influenced this for the therapy, potentially important parameter. Monte Carlo (MC) simulations of the absorbed dose distribution in the phantom were also performed. The results show that when the heights of the irradiated swaths were below those applicable to clinical therapy (<1 mm) the MC simulations produce estimates of PVDRs that are up to a factor of 3 higher than the measured values. For arrays of higher microbeams (i.e., 25 {mu}mx1 cm instead of 25x500 {mu}m{sup 2}), this difference between measured and simulated PVDRs becomes less than 50%. Closer agreement was observed between the measured and simulated PVDRs for the Tecomet MSC (current collimator design) than for the Archer MSC. Sources of discrepancies between measured and simulated doses are discussed, of which the energy dependent response of the MOSFET was shown to be among the most important.

  10. High spatial resolution mid-infrared studies of planetary systems

    NASA Astrophysics Data System (ADS)

    Skemer, Andrew

    I present the results of six papers related the formation and evolution of planets and planetary systems, all of which are based on high-resolution, ground-based, mid-infrared observations. The first three chapters are studies of T Tauri binaries. T Tauri stars are young, low mass stars, whose disks form the building blocks of extrasolar planets. The first chapter is a study of the 0.68"/0.12" triple system, T Tauri. Our spatially resolved N-band photometry reveals silicate absorption towards one component, T Tau Sa, indicating the presence of an edge-on disk, which is in contrast to the other components. The second chapter is an adaptive optics fed N-band spectroscopy study of the 0.88" binary, UY Aur. We find that the dust grains around UY Aur A are ISM-like, while the mineralogy of the dust around UY Aur B is more uncertain, due to self-extinction. The third chapter presents a survey of spatially resolved silicate spectroscopy for nine T Tauri binaries. We find with 90%-95% confidence that the silicate features of the binaries are more similar than those of randomly paired single stars. This implies that a shared binary property, such as age or composition, is an important parameter in dust grain evolution. The fourth chapter is a study of the planetary system, 2MASS 1207. We explore the source of 2MASS 1207 b's under-luminosity, which has typically been explained as the result of an edge-on disk of large, grey-extincting dust grains. We find that the edge-on disk theory is incompatible with several lines of evidence, and suggest that 2MASS 1207 b's appearance can be explained by a thick cloudy atmosphere, which might be typical among young, planetary systems. The fifth chapter is a study of the white dwarf, Sirius B, which in the context of this thesis is being studied as a post-planetary system. Our N-band imaging demonstrates that Sirius B does not have an infrared excess, in contrast to previous results. The sixth chapter is a study of mid

  11. Open issues in hyperspectral imaging for diagnostics on paintings: when high-spectral and spatial resolution turns into data redundancy

    NASA Astrophysics Data System (ADS)

    Cucci, Costanza; Casini, Andrea; Picollo, Marcello; Poggesi, Marco; Stefani, Lorenzo

    2011-06-01

    Hyper-Spectral Imaging (HSI) has emerged in the last decade as one of the most promising technologies for diagnostics and documentation of polychrome surfaces. Despite the fact that presently HSI is a well-established technique for non-invasive investigations on paintings, a number of technological issues remain open and are still topics for on-going studies. In particular, it is known that high spatial resolution is a crucial parameter for obtaining high quality images, whereas the possibility to identify pictorial materials strictly depends on the spectral resolution and on the extent of the spectral region investigated. At the same time, by increasing the sampling rates in both the spatial and spectral dimensions, the size of the data-set will be enlarged and the acquisition times will be lengthened. As a consequence, a good compromise between the acquisition of highquality data and their application should always be reached, taking into account the specific purposes of the HSI application. The above questions are discussed in the present work, which illustrates two applications of the latest version of a hyperspectral scanner designed at IFAC-CNR for the digitization of artworks. The prototype has recently been upgraded, with new visualization software as well as mechanical and optical improvements. This high performance system operates in the 400-1000nm spectral range, with a spectral resolution of about 2-3 nm and a spatial sampling of 0.1 mm over areas of about 1 m2. Three case-studies are presented, which highlight the importance of both high spatial and high spectral sampling rate in hyperspectral imaging. Two of the examples reported focus on the full exploitation of the spatial resolution: the first one is a study performed on a small painting, dated from the eighteenth century and belonging to the Uffizi Gallery in Florence; the second case-study refers to the valuable "Carrand diptych" (14th century) from the Bargello Museum in Florence. The last

  12. Auditory spatial resolution in horizontal, vertical, and diagonal planes.

    PubMed

    Grantham, D Wesley; Hornsby, Benjamin W Y; Erpenbeck, Eric A

    2003-08-01

    Minimum audible angle (MAA) and minimum audible movement angle (MAMA) thresholds were measured for stimuli in horizontal, vertical, and diagonal (60 degrees) planes. A pseudovirtual technique was employed in which signals were recorded through KEMAR's ears and played back to subjects through insert earphones. Thresholds were obtained for wideband, high-pass, and low-pass noises. Only 6 of 20 subjects obtained wideband vertical-plane MAAs less than 10 degrees, and only these 6 subjects were retained for the complete study. For all three filter conditions thresholds were lowest in the horizontal plane, slightly (but significantly) higher in the diagonal plane, and highest for the vertical plane. These results were similar in magnitude and pattern to those reported by Perrott and Saberi [J. Acoust. Soc. Am. 87, 1728-1731 (1990)] and Saberi and Perrott [J. Acoust. Soc. Am. 88, 2639-2644 (1990)], except that these investigators generally found that thresholds for diagonal planes were as good as those for the horizontal plane. The present results are consistent with the hypothesis that diagonal-plane performance is based on independent contributions from a horizontal-plane system (sensitive to interaural differences) and a vertical-plane system (sensitive to pinna-based spectral changes). Measurements of the stimuli recorded through KEMAR indicated that sources presented from diagonal planes can produce larger interaural level differences (ILDs) in certain frequency regions than would be expected based on the horizontal projection of the trajectory. Such frequency-specific ILD cues may underlie the very good performance reported in previous studies for diagonal spatial resolution. Subjects in the present study could apparently not take advantage of these cues in the diagonal-plane condition, possibly because they did not externalize the images to their appropriate positions in space or possibly because of the absence of a patterned visual field.

  13. Trade-off between angular and spatial resolutions in in vivo fiber tractography.

    PubMed

    Vos, Sjoerd B; Aksoy, Murat; Han, Zhaoying; Holdsworth, Samantha J; Maclaren, Julian; Viergever, Max A; Leemans, Alexander; Bammer, Roland

    2016-04-01

    Tractography is becoming an increasingly popular method to reconstruct white matter connections in vivo. The diffusion MRI data that tractography is based on requires a high angular resolution to resolve crossing fibers whereas high spatial resolution is required to distinguish kissing from crossing fibers. However, scan time increases with increasing spatial and angular resolutions, which can become infeasible in clinical settings. Here we investigated the trade-off between spatial and angular resolutions to determine which of these factors is most worth investing scan time in. We created a unique diffusion MRI dataset with 1.0 mm isotropic resolution and a high angular resolution (100 directions) using an advanced 3D diffusion-weighted multi-slab EPI acquisition. This dataset was reconstructed to create subsets of lower angular (75, 50, and 25 directions) and lower spatial (1.5, 2.0, and 2.5 mm) resolution. Using all subsets, we investigated the effects of angular and spatial resolutions in three fiber bundles-the corticospinal tract, arcuate fasciculus and corpus callosum-by analyzing the volumetric bundle overlap and anatomical correspondence between tracts. Our results indicate that the subsets of 25 and 50 directions provided inferior tract reconstructions compared with the datasets with 75 and 100 directions. Datasets with spatial resolutions of 1.0, 1.5, and 2.0 mm were comparable, while the lowest resolution (2.5 mm) datasets had discernible inferior quality. In conclusion, we found that angular resolution appeared to be more influential than spatial resolution in improving tractography results. Spatial resolutions higher than 2.0 mm only appear to benefit multi-fiber tractography methods if this is not at the cost of decreased angular resolution.

  14. Comparison of alternative spatial resolutions in the application of a spatially distributed biogeochemical model over complex terrain

    USGS Publications Warehouse

    Turner, D.P.; Dodson, R.; Marks, D.

    1996-01-01

    Spatially distributed biogeochemical models may be applied over grids at a range of spatial resolutions, however, evaluation of potential errors and loss of information at relatively coarse resolutions is rare. In this study, a georeferenced database at the 1-km spatial resolution was developed to initialize and drive a process-based model (Forest-BGC) of water and carbon balance over a gridded 54976 km2 area covering two river basins in mountainous western Oregon. Corresponding data sets were also prepared at 10-km and 50-km spatial resolutions using commonly employed aggregation schemes. Estimates were made at each grid cell for climate variables including daily solar radiation, air temperature, humidity, and precipitation. The topographic structure, water holding capacity, vegetation type and leaf area index were likewise estimated for initial conditions. The daily time series for the climatic drivers was developed from interpolations of meteorological station data for the water year 1990 (1 October 1989-30 September 1990). Model outputs at the 1-km resolution showed good agreement with observed patterns in runoff and productivity. The ranges for model inputs at the 10-km and 50-km resolutions tended to contract because of the smoothed topography. Estimates for mean evapotranspiration and runoff were relatively insensitive to changing the spatial resolution of the grid whereas estimates of mean annual net primary production varied by 11%. The designation of a vegetation type and leaf area at the 50-km resolution often subsumed significant heterogeneity in vegetation, and this factor accounted for much of the difference in the mean values for the carbon flux variables. Although area wide means for model outputs were generally similar across resolutions, difference maps often revealed large areas of disagreement. Relatively high spatial resolution analyses of biogeochemical cycling are desirable from several perspectives and may be particularly important in the

  15. Technical Note: Spatial resolution of proton tomography: Impact of air gap between patient and detector

    SciTech Connect

    Schneider, Uwe; Besserer, Juergen; Hartmann, Matthias

    2012-02-15

    Purpose: Proton radiography and tomography were investigated since the early 1970s because of its low radiation dose, high density resolution, and ability to image directly proton stopping power. However, spatial resolution is still a limiting factor. In this note, preliminary results of the impact of an air gap between detector system and patient on spatial resolution are presented. Methods: Spatial resolution of proton radiography and tomography is governed by multiple Coulomb scattering (MCS) of the protons in the patient. In this note, the authors employ Monte Carlo simulations of protons traversing a 20 cm thick water box. Entrance and exit proton coordinate measurements were simulated for improved spatial resolution. The simulations were performed with and without a 5 cm air gap in front of and behind the patient. Loss of spatial resolution due to the air gap was studied for protons with different initial angular confusion. Results: It was found that spatial resolution is significantly deteriorated when a 5 cm air gap between the position sensitive detector and the patient is included. For a perfect parallel beam spatial resolution worsens by about 40%. Spatial resolution is getting worse with increasing angular confusion and can reach 80%. Conclusions: When proton radiographies are produced by measuring the entrance and exit coordinates of the protons in front of and behind the patient the air gap between the detector and the patient can significantly deteriorate the spatial resolution of the system by up to 80%. An alternative would be to measure in addition to the coordinates also the exit and entrance angles of each proton. In principle, using the air gap size and proton angle, images can be reconstructed with the same spatial resolution than without air gap.

  16. Spatial resolution in CBCT machines for dental/maxillofacial applications—what do we know today?

    PubMed Central

    Schulze, R K W

    2015-01-01

    Spatial resolution is one of the most important parameters objectively defining image quality, particularly in dental imaging, where fine details often have to be depicted. Here, we review the current status on assessment parameters for spatial resolution and on published data regarding spatial resolution in CBCT images. The current concepts of visual [line-pair (lp) measurements] and automated [modulation transfer function (MTF)] assessment of spatial resolution in CBCT images are summarized and reviewed. Published measurement data on spatial resolution in CBCT are evaluated and analysed. Effective (i.e. actual) spatial resolution available in CBCT images is being influenced by the two-dimensional detector, the three-dimensional reconstruction process, patient movement during the scan and various other parameters. In the literature, the values range between 0.6 and 2.8 lp mm−1 (visual assessment; median, 1.7 lp mm−1) vs MTF (range, 0.5–2.3 cycles per mm; median, 2.1 lp mm−1). Spatial resolution of CBCT images is approximately one order of magnitude lower than that of intraoral radiographs. Considering movement, scatter effects and other influences in real-world scans of living patients, a realistic spatial resolution of just above 1 lp mm−1 could be expected. PMID:25168812

  17. High-resolution full-field spatial coherence gated optical tomography using monochromatic light source

    NASA Astrophysics Data System (ADS)

    Srivastava, Vishal; Nandy, Sreyankar; Singh Mehta, Dalip

    2013-09-01

    We demonstrate dispersion free, high-resolution full-field spatial coherence gated optical tomography using spatially incoherent monochromatic light source. Spatial coherence properties of light source were synthesized by means of combining a static diffuser and vibrating multi mode fiber bundle. Due to low spatial coherence of light source, the axial resolution of the system was achieved similar to that of conventional optical coherence tomography which utilizes low temporal coherence. Experimental results of fringe visibility versus optical path difference are presented for varying numerical apertures objective lenses. High resolution optically sectioned images of multilayer onion skin, and red blood cells are presented.

  18. Selecting the spatial resolution of satellite sensors required for global monitoring of land transformations

    NASA Technical Reports Server (NTRS)

    Townshend, J. R. G.; Justice, C. O.

    1988-01-01

    The paper provides preliminary evidence for the spatial resolutions required to monitor land transformations at broad scales. This is obtained from simulations of imagery at various spatial resolutions between 125 and 4000 m derived from Landsat MSS imagery. Consideration is given to the various types of spatial images detectable by remotely-sensed systems, as well as to the difficulties associated in disentangling permanent land transformations from shorter term changes such as phenological and interannual changes.

  19. Use of UAS remote sensing data to estimate crop ET at high spatial resolution

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Estimation of the spatial distribution of evapotranspiration (ET) based on remotely sensed imagery has become useful for managing water in irrigated agricultural at various spatial scales. However, data acquired by conventional satellites (Landsat, ASTER, etc.) lack the spatial resolution to capture...

  20. Estimating the spatial resolution of in vivo magnetic resonance images using radiofrequency tagging pulses.

    PubMed

    Wang, Wen-Tung; Hu, Peng; Meyer, Craig H

    2007-07-01

    The spatial resolution of magnetic resonance (MR) images is usually specified by using nominal spatial resolution, the width of the simulated point-spread function (PSF), or measurement from a resolution phantom. The accuracy of these measures is limited because they do not take into account the effects of in vivo image degradation. In this work, tag lines were used to estimate the spatial resolution of in vivo MR images. The idea of using tag lines to measure resolution was originally proposed by Wayte and Redpath (Magn Reson Imaging 1998;16:37-44), who used sinusoidal tag profiles and calculated an indirect measure of resolution called the modulation percentage. This work uses widely separated thin tag lines to directly measure the shape of the PSF and produce estimates of the PSF width in millimeters. The feasibility of estimating the spatial resolution via tag lines was evaluated using phantom images. The results show that an accurate estimate can be obtained when the tag modulation width is equal to or less than one-half of the best possible resolution. The tag lines are then used to demonstrate the asymmetry and spatial variation of spatial resolution of in vivo images acquired by using a turbo spin-echo (TSE) and a spiral sequence.

  1. Standard Reticle Slide To Objectively Evaluate Spatial Resolution and Instrument Performance in Imaging Mass Spectrometry.

    PubMed

    Zubair, Faizan; Prentice, Boone M; Norris, Jeremy L; Laibinis, Paul E; Caprioli, Richard M

    2016-07-19

    Spatial resolution is a key parameter in imaging mass spectrometry (IMS). Aside from being a primary determinant in overall image quality, spatial resolution has important consequences on the acquisition time of the IMS experiment and the resulting file size. Hardware and software modifications during instrumentation development can dramatically affect the spatial resolution achievable using a given imaging mass spectrometer. As such, an accurate and objective method to determine the working spatial resolution is needed to guide instrument development and ensure quality IMS results. We have used lithographic and self-assembly techniques to fabricate a pattern of crystal violet as a standard reticle slide for assessing spatial resolution in matrix-assisted laser desorption/ionization (MALDI) IMS experiments. The reticle is used to evaluate spatial resolution under user-defined instrumental conditions. Edgespread analysis measures the beam diameter for a Gaussian profile and line scans measure an "effective" spatial resolution that is a convolution of beam optics and sampling frequency. The patterned crystal violet reticle was also used to diagnose issues with IMS instrumentation such as intermittent losses of pixel data. PMID:27299987

  2. Influence of Regional Climate Model spatial resolution on wind climates

    NASA Astrophysics Data System (ADS)

    Pryor, S. C.; Barthelmie, R. J.; Nikulin, G.; Jones, C.

    2010-12-01

    Global and regional climate models are being run at increasingly fine horizontal and vertical resolution with the goal of increased skill. However, relatively few studies have quantified the change in modeled wind climates that derives from applying a Regional Climate Model (RCM) at varying resolutions, and the response to varying resolution may be highly non-linear since most models run in climate mode are hydrostatic. Thus, herein we examine the influence of grid-resolution on modelled wind speeds and gusts and derived extremes thereof over southern Scandinavia using output from the Rossby Centre (RCA3) RCM run at four different resolutions from 50 x 50 km to 6 x 6 km, and with two different vertical grid-spacings. Domain averaged fifty-year return period wind speeds and wind gusts derived using the method of moments approach to compute the Gumbel parameters, increase with resolution (Table 1), though the change is strongly mediated by the model grid-cell surface characteristics. Power spectra of the 3-hourly model time-step ‘instantaneous’ wind speeds and daily wind gusts at all four resolutions show clear peaks in the variance associated with bi-annual, annual, seasonal and synoptic frequencies. The variance associated with these peaks is enhanced with increased resolution, though not in a monotonic fashion, and is more marked in wind gusts than wind speeds. Relative to in situ observations, the model generally underestimates the variance, particularly associated with the synoptic time scale, even for the highest resolution simulations. There is some evidence to suggest that the change in the power spectra with horizontal resolution is less marked in the transition from 12.5 km to 6.25 km, than from 50 to 25 km, or 25 km to 12.5 km.Table 1. Domain averaged mean annual wind speed (U), 50-year return period extreme wind speed (U50yr) and wind gust (Gust50yr) (m/s) from the four RCA3 simulations at different resolution based on output from 1987-2008. The

  3. Using remote sensing products to classify landscape. A multi-spatial resolution approach

    NASA Astrophysics Data System (ADS)

    García-Llamas, Paula; Calvo, Leonor; Álvarez-Martínez, José Manuel; Suárez-Seoane, Susana

    2016-08-01

    The European Landscape Convention encourages the inventory and characterization of landscapes for environmental management and planning actions. Among the range of data sources available for landscape classification, remote sensing has substantial applicability, although difficulties might arise when available data are not at the spatial resolution of operational interest. We evaluated the applicability of two remote sensing products informing on land cover (the categorical CORINE map at 30 m resolution and the continuous NDVI spectral index at 1 km resolution) in landscape classification across a range of spatial resolutions (30 m, 90 m, 180 m, 1 km), using the Cantabrian Mountains (NW Spain) as study case. Separate landscape classifications (using topography, urban influence and land cover as inputs) were accomplished, one per each land cover dataset and spatial resolution. Classification accuracy was estimated through confusion matrixes and uncertainty in terms of both membership probability and confusion indices. Regarding landscape classifications based on CORINE, both typology and number of landscape classes varied across spatial resolutions. Classification accuracy increased from 30 m (the original resolution of CORINE) to 90m, decreasing towards coarser resolutions. Uncertainty followed the opposite pattern. In the case of landscape classifications based on NDVI, the identified landscape patterns were geographically structured and showed little sensitivity to changes across spatial resolutions. Only the change from 1 km (the original resolution of NDVI) to 180 m improved classification accuracy. The value of confusion indices increased with resolution. We highlight the need for greater effort in selecting data sources at the suitable spatial resolution, matching regional peculiarities and minimizing error and uncertainty.

  4. Spatial Resolution and Refractive Index Contrast of Resonant Photonic Crystal Surfaces for Biosensing

    PubMed Central

    Triggs, G. J.; Fischer, M.; Stellinga, D.; Scullion, M. G.; Evans, G. J. O.; Krauss, T. F.

    2015-01-01

    By depositing a resolution test pattern on top of a Si3N4 photonic crystal resonant surface, we have measured the dependence of spatial resolution on refractive index contrast Δn. Our experimental results and finite-difference time-domain (FDTD) simulations at different refractive index contrasts show that the spatial resolution of our device reduces with reduced contrast, which is an important consideration in biosensing, where the contrast may be of order 10−2. We also compare 1-D and 2-D gratings, taking into account different incidence polarizations, leading to a better understanding of the excitation and propagation of the resonant modes in these structures, as well as how this contributes to the spatial resolution. At Δn = 0.077, we observe resolutions of 2 and 6 μm parallel to and perpendicular to the grooves of a 1-D grating, respectively, and show that for polarized illumination of a 2-D grating, resolution remains asymmetrical. Illumination of a 2-D grating at 45° results in symmetric resolution. At very low index contrast, the resolution worsens dramatically, particularly for Δn < 0.01, where we observe a resolution exceeding 10 μm for our device. In addition, we measure a reduction in the resonance linewidth as the index contrast becomes lower, corresponding to a longer resonant mode propagation length in the structure and contributing to the change in spatial resolution. PMID:26356353

  5. Exploring the spatial resolution of position-sensitive microchannel plate detectors

    NASA Astrophysics Data System (ADS)

    Wiggins, Blake; Siwal, Davinder; Desouza, Romualdo

    2016-03-01

    High amplification and excellent timing make microchannel plate (MCP) detectors excellent devices for detection of photons, electrons, and ions. In addition to providing sub-nanosecond time resolution MCP detectors can also provide spatial resolution, thus making them useful in imaging applications. Use of a resistive anode (RA) is a routinely used approach to make an MCP position-sensitive. The spatial resolution of the RA associated with detection of a single incident electron was determined. Factors impacting the spatial resolution obtained with the RA will be discussed and the achieved spatial resolution of 64 μm (FWHM) will be presented. Recently, a novel approach has been developed to provide position-sensitivity for an MCP detector. In this approach, namely the induced signal approach, the position of the incident particle is determined by sensing the electron cloud emanating from a MCP stack. By utilizing the zero-crossing point of the inherently bipolar signals, a spatial resolution of 466 μm (FWHM) has been achieved. Work to improve the spatial resolution of the induced signal approach further will be presented. Supported by the US DOE NNSA under Award No. DE-NA0002012.

  6. Additional studies of forest classification accuracy as influenced by multispectral scanner spatial resolution

    NASA Technical Reports Server (NTRS)

    Sadowski, F. E.; Sarno, J. E.

    1976-01-01

    First, an analysis of forest feature signatures was used to help explain the large variation in classification accuracy that can occur among individual forest features for any one case of spatial resolution and the inconsistent changes in classification accuracy that were demonstrated among features as spatial resolution was degraded. Second, the classification rejection threshold was varied in an effort to reduce the large proportion of unclassified resolution elements that previously appeared in the processing of coarse resolution data when a constant rejection threshold was used for all cases of spatial resolution. For the signature analysis, two-channel ellipse plots showing the feature signature distributions for several cases of spatial resolution indicated that the capability of signatures to correctly identify their respective features is dependent on the amount of statistical overlap among signatures. Reductions in signature variance that occur in data of degraded spatial resolution may not necessarily decrease the amount of statistical overlap among signatures having large variance and small mean separations. Features classified by such signatures may thus continue to have similar amounts of misclassified elements in coarser resolution data, and thus, not necessarily improve in classification accuracy.

  7. A small-sized MWPC with 1 mm wire spacing as a beam/target chamber for nuclear experiments

    NASA Astrophysics Data System (ADS)

    Ninomiya, M.; Arai, I.; Manabe, A.; Nunokawa, H.; Tanaka, M.; Tomizawa, K.; Yagi, K.; Kobayashi, T.; Chiba, J.; Nakai, K.; Sano, H.; Sasaki, S.; Nagae, T.; Tokushuku, K.; Sekimoto, M.

    1988-11-01

    We developed a small-sized multiwire proportional chamber with 1 mm wire spacing for a study of backward Λ production in high energy hadron-nucleus reactions. Two chambers were installed in a cylindrical drift chamber of the large aperture spectrometer FANCY in order to determine beam trajectories precisely. A position resolution of about 0.6 mm was obtained with a counting efficiency of 97%.

  8. EEG source analysis of epileptiform activity using a 1mm anisotropic hexahedra finite element head model

    PubMed Central

    Rullmann, M.; Anwander, A.; Dannhauer, M.; Warfield, S.K.; Duffy, F.H.; Wolters, C.H.

    2009-01-01

    The major goal of the evaluation in presurgical epilepsy diagnosis for medically intractable patients is the precise reconstruction of the epileptogenic foci, preferably with non-invasive methods. This paper evaluates whether surface electroencephalography (EEG) source analysis based on a 1mm anisotropic finite element (FE) head model can provide additional guidance for presurgical epilepsy diagnosis and whether it is practically feasible in daily routine. A 1mm hexahedra FE volume conductor model of the patient’s head with special focus on accurately modeling the compartments skull, cerebrospinal fluid (CSF) and the anisotropic conducting brain tissues was constructed using non-linearly co-registered T1-, T2- and diffusion-tensor- magnetic resonance imaging data. The electrodes of intra-cranial EEG (iEEG) measurements were extracted from a co-registered computed tomography image. Goal function scan (GFS), minimum norm least squares (MNLS), standardized low resolution electromagnetic tomography (sLORETA) and spatio-temporal current dipole modeling inverse methods were then applied to the peak of the averaged ictal discharges EEG data. MNLS and sLORETA pointed to a single center of activity. Moving and rotating single dipole fits resulted in an explained variance of more than 97%. The non-invasive EEG source analysis methods localized at the border of the lesion and at the border of the iEEG electrodes which mainly received ictal discharges. Source orientation was towards the epileptogenic tissue. For the reconstructed superficial source, brain conductivity anisotropy and the lesion conductivity had only a minor influence, whereas a correct modeling of the highly conducting CSF compartment and the anisotropic skull was found to be important. The proposed FE forward modeling approach strongly simplifies meshing and reduces run-time (37 Milliseconds for one forward computation in the model with 3.1 Million unknowns), corroborating the practical feasibility of the

  9. Definition of the Spatial Resolution of X-Ray Microanalysis in Thin Foils

    NASA Technical Reports Server (NTRS)

    Williams, D. B.; Michael, J. R.; Goldstein, J. I.; Romig, A. D., Jr.

    1992-01-01

    The spatial resolution of X-ray microanalysis in thin foils is defined in terms of the incident electron beam diameter and the average beam broadening. The beam diameter is defined as the full width tenth maximum of a Gaussian intensity distribution. The spatial resolution is calculated by a convolution of the beam diameter and the average beam broadening. This definition of the spatial resolution can be related simply to experimental measurements of composition profiles across interphase interfaces. Monte Carlo calculations using a high-speed parallel supercomputer show good agreement with this definition of the spatial resolution and calculations based on this definition. The agreement is good over a range of specimen thicknesses and atomic number, but is poor when excessive beam tailing distorts the assumed Gaussian electron intensity distributions. Beam tailing occurs in low-Z materials because of fast secondary electrons and in high-Z materials because of plural scattering.

  10. Physical Properties of the 1.1 mm selected Giant Molecular Clouds in the Small Magellanic Cloud

    NASA Astrophysics Data System (ADS)

    Takekoshi, Tatsuya

    2015-08-01

    The first 1.1 mm continuum survey toward the Small Magellanic Cloud (SMC) is performed with the AzTEC instrument installed on the ASTE 10 m telescope. This survey covers 4.5 square degrees of the SMC, and achieves the 1σ noise levels of 5-13 mJy beam-1. As a result of the analysis, 44 extended objects are identified. The 1.1 mm extended emission has good spatial correlation with 160 μm, indicating that the origin of the 1.1 mm continuum is thermal emission from cold dust component. Spectral energy distribution analysis are performed assuming single-temperature thermal emission from the cold dust component. Assuming a gas-to-dust ratio of 1000, the 1.1 mm objects have gas mass ranges from 7×103 to 4×105 M⊙, which is typical mass range of giant molecular clouds (GMCs), implying that the detected objects are dust-selected GMCs. The 1.1 mm objects show good spatial correlation with the 24 μm and CO emission, and the physical properties are very similar to that of our Galaxy and the Large Magellanic Cloud. The existences of star formation activity or CO detection provide the information about the evolutionary sequence. Comparisions with signs of star-formation and CO emission provide information about the evolutionary sequence. We found 2, 8, 13, and 21 samples of the starless/CO-detected, starless/CO-dark, star-forming/CO-dark, and star-forming/CO-detected objects, respectively. This result implies the existence of three main evolutionary phases, and the starless/CO-dark samples can be explained as the youngest evolution phase of GMCs. The deficiency of the starless/CO-detected samples suggests that the detectable amount of CO forms after the onset of star formation in the low metallicity environment of the SMC.

  11. Atmospheric Correction Prototype Algorithm for High Spatial Resolution Multispectral Earth Observing Imaging Systems

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary

    2006-01-01

    This viewgraph presentation reviews the creation of a prototype algorithm for atmospheric correction using high spatial resolution earth observing imaging systems. The objective of the work was to evaluate accuracy of a prototype algorithm that uses satellite-derived atmospheric products to generate scene reflectance maps for high spatial resolution (HSR) systems. This presentation focused on preliminary results of only the satellite-based atmospheric correction algorithm.

  12. A condition on the spatial resolution of IR collimators for testing of thermal imaging systems

    NASA Astrophysics Data System (ADS)

    Chrzanowski, Krzysztof; Lee, Hee Chul; Wrona, Wieslaw

    2000-05-01

    A precise condition on the spatial resolution of the IR collimator for testing thermal imaging systems is presented. The condition can be used even if only the spatial resolution of the IR collimator and that of the system under test, measured using popular definitions, are known. It is shown that when the condition is fulfilled, the thermal image degradation caused by the IR collimator is negligible.

  13. Imaging at high spatial resolution: Soft x-ray microscopy to 15nm

    SciTech Connect

    Attwood, D.; Chao, W.; Anderson, E.; Liddle, J.A.; Harteneck, B.; Fischer, P.; Schneider, G.; Le Gros, M.; Larabell, C.

    2006-04-05

    Soft x-ray microscopy has now achieved 15 nm spatial resolution with new zone plates and bending magnet radiation. Combined with elemental sensitivity and flexible sample environment (applied magnetic or electric fields, wet samples, windows, overcoatings) this emerges as a valuable tool for nanoscience and nanotechnology, complimenting common electron and scanning tip microscopies. In this presentation we describe recent advances in spatial resolution, expectations for the near future, and applications to magnetic materials, bio-tomography, etc.

  14. Pushing the limit of the distributed Brillouin sensors for the sensing length and the spatial resolution

    NASA Astrophysics Data System (ADS)

    Bao, Xiaoyi; Liang, Hao; Dong, Yongkang; Li, Wenhai; Li, Yun; Chen, Liang

    2010-04-01

    Long distance sensing based on Brillouin scattering with centimeter spatial resolution, and yet high strain or temperature resolution requires the optimization of the optical and electronic system. In optical domain the limiting factors include gain saturation of the Stokes signal and pump depletion induced the Brillouin spectrum distortion, and thus a low gain is desired that requires low pump power, which sets a limit in the signal to noise ratio (SNR). The detection system must have high gain and narrow bandwidth to reduce electronic noise. The coded pulse offers the best solution as a low power solution of long distance sensing based on BOTDA to improve the signal to noise ratio (SNR), comparing two most common used formats: non-return-to-zero (NRZ) and return-to-zero (RZ), RZ coded pulses offer minimum distortion in the spatial resolution and the Brillouin spectrum, because the signal in RZ format returns to zero in very bit, while in NRZ coded pulse the signal returns to zero after continuous "1"s, which brings the higher gain and lower bandwidth comparing that in RZ coded pulse for BOTDA system. Hence NRZ coded pulse BOTDA would introduce spatial broadening and lower the spatial resolution. With minimum distortion of RZ signal we can use differential Brillouin gain to realize DPP-BOTDA technique for sub-meter spatial resolution. The minimum coded pulse width must be larger than the acoustic wave relaxation time to avoid the distorted Brillouin gain spectrum. Using LEAF fiber we achieved 50km sensing length and 50cm spatial resolution with the strain resolution of 8μɛ which is equivalent to 0.7MHz Brillouin frequency shift, this is the 1st sub-meter spatial resolution for 50km sensing length combined with high strain resolution.

  15. Position dependent spatial and spectral resolution measurement of distributed readout superconducting imaging detectors

    NASA Astrophysics Data System (ADS)

    Hijmering, R. A.; Verhoeve, P.; Kozorezov, A. G.; Martin, D. D. E.; Wigmore, J. K.; Jerjen, I.; Venn, R.; Groot, P. J.

    2008-04-01

    We present direct measurements of spatial and spectral resolution of cryogenic distributed readout imaging detectors (DROIDs). The spatial and spectral resolutions have been experimentally determined by scanning a 10μm spot of monochromatic visible light across the detector. The influences of the photon energy, bias voltage, and absorber length and width on the spatial and spectral resolutions have been examined. The confinement of quasiparticles in the readout sensors (superconducting tunnel junctions) as well as the detector's signal amplitude can be optimized by tuning the bias voltage, thereby improving both the spatial and spectral resolutions. Changing the length of the absorber affects the spatial and spectral resolutions in opposite manner, making it an important parameter to optimize the DROID for the application at hand. The results have been used to test expressions for photon energy, position, and spatial and spectral resolutions which have been derived by using an existing one-dimensional model. The model is found to accurately describe the experimental data, but some limitations have been identified. In particular, the model's assumption that the two sensors have identical response characteristics and noise, the approximation of the detailed quasiparticle dynamics in the sensors by border conditions, and the use of a one-dimensional diffusion process is not always adequate.

  16. Calculation of the spatial resolution in two-photon absorption spectroscopy applied to plasma diagnosis

    SciTech Connect

    Garcia-Lechuga, M.; Fuentes, L. M.; Grützmacher, K.; Pérez, C. Rosa, M. I. de la

    2014-10-07

    We report a detailed characterization of the spatial resolution provided by two-photon absorption spectroscopy suited for plasma diagnosis via the 1S-2S transition of atomic hydrogen for optogalvanic detection and laser induced fluorescence (LIF). A precise knowledge of the spatial resolution is crucial for a correct interpretation of measurements, if the plasma parameters to be analysed undergo strong spatial variations. The present study is based on a novel approach which provides a reliable and realistic determination of the spatial resolution. Measured irradiance distribution of laser beam waists in the overlap volume, provided by a high resolution UV camera, are employed to resolve coupled rate equations accounting for two-photon excitation, fluorescence decay and ionization. The resulting three-dimensional yield distributions reveal in detail the spatial resolution for optogalvanic and LIF detection and related saturation due to depletion. Two-photon absorption profiles broader than the Fourier transform-limited laser bandwidth are also incorporated in the calculations. The approach allows an accurate analysis of the spatial resolution present in recent and future measurements.

  17. Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants

    NASA Astrophysics Data System (ADS)

    Wilke, R. G. H.; Khalili Moghadam, G.; Lovell, N. H.; Suaning, G. J.; Dokos, S.

    2011-08-01

    Active multi-electrode arrays are used in vision prostheses, including optic nerve cuffs and cortical and retinal implants for stimulation of neural tissue. For retinal implants, arrays with up to 1500 electrodes are used in clinical trials. The ability to convey information with high spatial resolution is critical for these applications. To assess the extent to which spatial resolution is impaired by electric crosstalk, finite-element simulation of electric field distribution in a simplified passive tissue model of the retina is performed. The effects of electrode size, electrode spacing, distance to target cells, and electrode return configuration (monopolar, tripolar, hexagonal) on spatial resolution is investigated in the form of a mathematical model of electric field distribution. Results show that spatial resolution is impaired with increased distance from the electrode array to the target cells. This effect can be partly compensated by non-monopolar electrode configurations and larger electrode diameters, albeit at the expense of lower pixel densities due to larger covering areas by each stimulation electrode. In applications where multi-electrode arrays can be brought into close proximity to target cells, as presumably with epiretinal implants, smaller electrodes in monopolar configuration can provide the highest spatial resolution. However, if the implantation site is further from the target cells, as is the case in suprachoroidal approaches, hexagonally guarded electrode return configurations can convey higher spatial resolution. This paper was originally submitted for the special issue containing contributions from the Sixth Biennial Research Congress of The Eye and the Chip.

  18. Electric crosstalk impairs spatial resolution of multi-electrode arrays in retinal implants.

    PubMed

    Wilke, R G H; Moghadam, G Khalili; Lovell, N H; Suaning, G J; Dokos, S

    2011-08-01

    Active multi-electrode arrays are used in vision prostheses, including optic nerve cuffs and cortical and retinal implants for stimulation of neural tissue. For retinal implants, arrays with up to 1500 electrodes are used in clinical trials. The ability to convey information with high spatial resolution is critical for these applications. To assess the extent to which spatial resolution is impaired by electric crosstalk, finite-element simulation of electric field distribution in a simplified passive tissue model of the retina is performed. The effects of electrode size, electrode spacing, distance to target cells, and electrode return configuration (monopolar, tripolar, hexagonal) on spatial resolution is investigated in the form of a mathematical model of electric field distribution. Results show that spatial resolution is impaired with increased distance from the electrode array to the target cells. This effect can be partly compensated by non-monopolar electrode configurations and larger electrode diameters, albeit at the expense of lower pixel densities due to larger covering areas by each stimulation electrode. In applications where multi-electrode arrays can be brought into close proximity to target cells, as presumably with epiretinal implants, smaller electrodes in monopolar configuration can provide the highest spatial resolution. However, if the implantation site is further from the target cells, as is the case in suprachoroidal approaches, hexagonally guarded electrode return configurations can convey higher spatial resolution. PMID:21673395

  19. Spatial resolution of confocal XRF technique using capillary optics

    PubMed Central

    2013-01-01

    XRF (X-ray fluorescence) is a powerful technique for elemental analysis with a high sensitivity. The resolution is presently limited by the size of the primary excitation X-ray beam. A test-bed for confocal-type XRF has been developed to estimate the ultimate lateral resolution which could be reached in chemical mapping using this technique. A polycapillary lens is used to tightly focus the primary X-ray beam of a low power rhodium X-ray source, while the fluorescence signal is collected by a SDD detector through a cylindrical monocapillary. This system was used to characterize the geometry of the fluorescent zone. Capillary radii ranging from 50 μm down to 5 μm were used to investigate the fluorescence signal maximum level This study allows to estimate the ultimate resolution which could be reached in-lab or on a synchrotron beamline. A new tool combining local XRF and scanning probe microscopy is finally proposed. PMID:23758858

  20. Super Resolution from Hyperview Image Stack by Spatial Multiplexing

    NASA Astrophysics Data System (ADS)

    Grasnick, Armin

    2016-09-01

    An image stack for a hyperview representation could contain millions of different perspective views with extreme image similarity. The recording of all views from a computational 3d model implicates a lateral displacement of the virtual camera. Because of the huge number of views, the offset in between two adjoining camera positions can be very minor. If such a virtual setup reproduces a real hyperview screen setup, the offset can be below the wavelength of the visible light. But even with such small changes, there is an intrinsic probability for a measurable difference in between two neighbour images. Such image dissimilarity can be proofed successfully also in very basic 3d scenes. By using a quantity of juxtapositional images from the hyperview image stack, the resolution of the rendered images can be considerably improved, which is commonly known as super resolution. The utilisation of super resolution images in hyperview could cut the necessity of full frame computing and will reduce the effective render time.

  1. Spatial resolution of confocal XRF technique using capillary optics.

    PubMed

    Dehlinger, Maël; Fauquet, Carole; Lavandier, Sebastien; Aumporn, Orawan; Jandard, Franck; Arkadiev, Vladimir; Bjeoumikhov, Aniouar; Tonneau, Didier

    2013-06-07

    XRF (X-ray fluorescence) is a powerful technique for elemental analysis with a high sensitivity. The resolution is presently limited by the size of the primary excitation X-ray beam. A test-bed for confocal-type XRF has been developed to estimate the ultimate lateral resolution which could be reached in chemical mapping using this technique. A polycapillary lens is used to tightly focus the primary X-ray beam of a low power rhodium X-ray source, while the fluorescence signal is collected by a SDD detector through a cylindrical monocapillary. This system was used to characterize the geometry of the fluorescent zone. Capillary radii ranging from 50 μm down to 5 μm were used to investigate the fluorescence signal maximum level This study allows to estimate the ultimate resolution which could be reached in-lab or on a synchrotron beamline. A new tool combining local XRF and scanning probe microscopy is finally proposed.

  2. Spatial resolution of anthropogenic heat fluxes into urban aquifers.

    PubMed

    Benz, Susanne A; Bayer, Peter; Menberg, Kathrin; Jung, Stephan; Blum, Philipp

    2015-08-15

    Urban heat islands in the subsurface contain large quantities of energy in the form of elevated groundwater temperatures caused by anthropogenic heat fluxes (AHFS) into the subsurface. The objective of this study is to quantify these AHFS and the heat flow they generate in two German cities, Karlsruhe and Cologne. Thus, statistical and spatial analytical heat flux models were developed for both cities. The models include the spatial representation of various sources of AHFS: (1) elevated ground surface temperatures, (2) basements, (3) sewage systems, (4) sewage leakage, (5) subway tunnels, and (6) district heating networks. The results show that the district heating networks induce the largest AHFS with values greater than 60 W/m(2) and one order of magnitude higher than fluxes from other sources. A covariance analysis indicates that the spatial distribution of the total flux depends mainly on the thermal gradient in the unsaturated zone. On a citywide scale, basements and elevated ground surface temperatures are the dominant sources of heat flow. Overall, 2.1 PJ/a and 1.0 PJ/a of heat are accumulated on average in Karlsruhe and the western part of Cologne, respectively. Extracting this anthropogenically originated energy could sustainably supply significant parts of the urban heating demand. Furthermore, using this heat could also keep groundwater temperatures from rising further.

  3. Spatial resolution of anthropogenic heat fluxes into urban aquifers.

    PubMed

    Benz, Susanne A; Bayer, Peter; Menberg, Kathrin; Jung, Stephan; Blum, Philipp

    2015-08-15

    Urban heat islands in the subsurface contain large quantities of energy in the form of elevated groundwater temperatures caused by anthropogenic heat fluxes (AHFS) into the subsurface. The objective of this study is to quantify these AHFS and the heat flow they generate in two German cities, Karlsruhe and Cologne. Thus, statistical and spatial analytical heat flux models were developed for both cities. The models include the spatial representation of various sources of AHFS: (1) elevated ground surface temperatures, (2) basements, (3) sewage systems, (4) sewage leakage, (5) subway tunnels, and (6) district heating networks. The results show that the district heating networks induce the largest AHFS with values greater than 60 W/m(2) and one order of magnitude higher than fluxes from other sources. A covariance analysis indicates that the spatial distribution of the total flux depends mainly on the thermal gradient in the unsaturated zone. On a citywide scale, basements and elevated ground surface temperatures are the dominant sources of heat flow. Overall, 2.1 PJ/a and 1.0 PJ/a of heat are accumulated on average in Karlsruhe and the western part of Cologne, respectively. Extracting this anthropogenically originated energy could sustainably supply significant parts of the urban heating demand. Furthermore, using this heat could also keep groundwater temperatures from rising further. PMID:25930242

  4. Impact of spatial resolution of ocean models in depicting climate change patterns of the North Sea.

    NASA Astrophysics Data System (ADS)

    Narayan, Nikesh; Klein, Birgit; Mathis, Moritz; Klein, Holger; Mikolajewicz, Uwe

    2016-04-01

    The impact of enhanced spatial resolution of models in simulating large scale climate change has been of interest for the modeling community for quite some time. It has been noticed in previous studies that the pattern of Sea Surface Temperature anomalies are better captured by higher resolution models. Significant changes in simulating sea-ice loss associated with global warming was also noticed when the spatial resolution of climate models were enhanced. Spatial resolution is a particular important issue in climate change scenarios of shelf seas such as the North Sea. The North Sea is strongly influenced by its water mass exchanges with North Atlantic to the west and north and Baltic Sea to east. Furthermore, local forcing and changes in advected water masses significantly affect the thermodynamics and stratification patterns in the North Sea, making it a challenging area to study. Under the newly started RACE2 project we are looking at global simulations of Representative Concentration Pathway (RCP) scenarios 4.5 and 8.5 at lower and higher resolutions, performed using the Max Planck Institute Earth System Model (MPIESM). The model resolution is non uniform and achieves the highest resolution over the European Seas by shifting the model poles over Chicago and Central Europe. In the high resolution run, the grid reaches up to a spatial resolution of up to 4 km in part of the German Bight and close to 20 km in the Northern part of North Sea. The placement of model poles at specific locations enables the global model to obtain higher resolution at regional scales (North Sea), without the inherent complications of open boundary conditions. High and low resolution simulations will be compared to determine differences in spatial and temporal pattern of temperature anomalies, fresh water intrusion from the Baltic Sea to North Sea etc. Also taken into consideration will be the changes in simulating local sea level change and response to basin scale oscillations like NAO.

  5. Whole-animal functional and developmental imaging with isotropic spatial resolution.

    PubMed

    Chhetri, Raghav K; Amat, Fernando; Wan, Yinan; Höckendorf, Burkhard; Lemon, William C; Keller, Philipp J

    2015-12-01

    Imaging fast cellular dynamics across large specimens requires high resolution in all dimensions, high imaging speeds, good physical coverage and low photo-damage. To meet these requirements, we developed isotropic multiview (IsoView) light-sheet microscopy, which rapidly images large specimens via simultaneous light-sheet illumination and fluorescence detection along four orthogonal directions. Combining these four views by means of high-throughput multiview deconvolution yields images with high resolution in all three dimensions. We demonstrate whole-animal functional imaging of Drosophila larvae at a spatial resolution of 1.1-2.5 μm and temporal resolution of 2 Hz for several hours. We also present spatially isotropic whole-brain functional imaging in Danio rerio larvae and spatially isotropic multicolor imaging of fast cellular dynamics across gastrulating Drosophila embryos. Compared with conventional light-sheet microscopy, IsoView microscopy improves spatial resolution at least sevenfold and decreases resolution anisotropy at least threefold. Compared with existing high-resolution light-sheet techniques, IsoView microscopy effectively doubles the penetration depth and provides subsecond temporal resolution for specimens 400-fold larger than could previously be imaged.

  6. Spatial Resolution, Grayscale, and Error Diffusion Trade-offs: Impact on Display System Design

    NASA Technical Reports Server (NTRS)

    Gille, Jennifer L. (Principal Investigator)

    1996-01-01

    We examine technology trade-offs related to grayscale resolution, spatial resolution, and error diffusion for tessellated display systems. We present new empirical results from our psychophysical study of these trade-offs and compare them to the predictions of a model of human vision.

  7. Local Optical Spectroscopies for Subnanometer Spatial Resolution Chemical Imaging

    SciTech Connect

    Weiss, Paul

    2014-01-20

    The evanescently coupled photon scanning tunneling microscopes (STMs) have special requirements in terms of stability and optical access. We have made substantial improvements to the stability, resolution, and noise floor of our custom-built visible-photon STM, and will translate these advances to our infrared instrument. Double vibration isolation of the STM base with a damping system achieved increased rigidity, giving high tunneling junction stability for long-duration and high-power illumination. Light frequency modulation with an optical chopper and phase-sensitive detection now enhance the signal-to-noise ratio of the tunneling junction during irradiation.

  8. Design Study of a Whole-Body PET Scanner with Improved Spatial and Timing Resolution

    PubMed Central

    Surti, S.; Shore, Adam R.; Karp, Joel S.

    2013-01-01

    Current state-of-art whole-body PET scanners achieve a system spatial resolution of 4–5 mm with limited sensitivity. Since the reconstructed spatial resolution and image quality are limited by the count statistics, there has not been a significant push for developing higher resolution whole-body PET scanners. Our goal in this study is to investigate the impact of improved spatial resolution together with time-of-flight (TOF) capability on lesion uptake estimation and lesion detectability, two important tasks in whole-body oncologic studies. The broader goal of this project is the development of a new state-of-art TOF PET scanner operating within an MRI while pushing the technology in PET system design. We performed Monte Carlo simulations to test the effects of crystal size (4 mm and 2.6 mm wide crystals), TOF timing resolution (300ps and 600ps), and 2-level depth-of-interaction (DOI) capability. Spatial resolution was calculated by simulating point sources in air at multiple positions. Results show that smaller crystals produced improved resolution, while degradation of resolution due to parallax error could be reduced with a 2-level DOI detector. Lesion phantoms were simulated to measure the contrast recovery coefficient (CRC) and area under the LROC curve (ALROC) for 0.5 cm diameter lesions with 6:1 activity uptake relative to the background. Smaller crystals produce higher CRC, leading to increased ALROC values or a reduction in scan time. Improved timing resolution provides faster CRC convergence and once again leads to an increase in ALROC value or reduced scan time. Based on our choice of timing resolution and crystal size, improved timing resolution (300ps) with larger crystals (4 mm wide) has similar ALROC as smaller crystals (2.6 mm wide) with 600ps timing resolution. A 2-level DOI measurement provides some CRC and ALROC improvement for lesions further away from the center, leading to a more uniform performance within the imaging field-of-view (FOV

  9. A neurodynamical model of visual attention: feedback enhancement of spatial resolution in a hierarchical system.

    PubMed

    Deco, G; Zihl, J

    2001-01-01

    Human beings have the capacity to recognize objects in natural visual scenes with high efficiency despite the complexity of such scenes, which usually contain multiple objects. One possible mechanism for dealing with this problem is selective attention. Psychophysical evidence strongly suggests that selective attention can enhance the spatial resolution in the input region corresponding to the focus of attention. In this work we adopt a computational neuroscience perspective to analyze the attentional enhancement of spatial resolution in the area containing the objects of interest. We extend and apply the computational model of Deco and Schürmann (2000), which consists of several modules with feedforward and feedback interconnections describing the mutual links between different areas of the visual cortex. Each module analyses the visual input with different spatial resolution and can be thought of as a hierarchical predictor at a given level of resolution. Moreover, each hierarchical predictor has a submodule that consists of a group of neurons performing a biologically based 2D Gabor wavelet transformation at a given resolution level. The attention control decides in which local regions the spatial resolution should be enhanced in a serial fashion. In this sense, the scene is first analyzed at a coarse resolution level, and the focus of attention enhances iteratively the resolution at the location of an object until the object is identified. We propose and simulate new psychophysical experiments where the effect of the attentional enhancement of spatial resolution can be demonstrated by predicting different reaction time profiles in visual search experiments where the target and distractors are defined at different levels of resolution.

  10. Measurement of velocity fluctuations in microfluidics with simultaneously ultrahigh spatial and temporal resolution

    NASA Astrophysics Data System (ADS)

    Zhao, Wei; Yang, Fang; Khan, Jamil; Reifsnider, Ken; Wang, Guiren

    2016-01-01

    Although unsteady and electrokinetic flows are widely used in microfluidics, there is unfortunately no velocimeter today that can measure the random velocity fluctuation at high temporal and spatial resolution simultaneously in microfluidics. Here we, for the first time, theoretically study the temporal resolution of laser induced fluorescence photobleaching anemometer (LIFPA) and experimentally verify that LIFPA can have simultaneously ultrahigh temporal ({˜ } 4 \\upmu s) and spatial ({˜ }203 nm) resolution and can measure velocity fluctuation up to at least 2 kHz, whose corresponding wave number is about 6× 10^6 {/}m in an electrokinetically forced unsteady flow in microfluidics.

  11. Study and optimization of the spatial resolution for detectors with binary readout

    NASA Astrophysics Data System (ADS)

    Yonamine, R.; Maerschalk, T.; Lentdecker, G. De

    2016-09-01

    Using simulations and analytical approaches, we have studied single hit resolutions obtained with a binary readout, which is often proposed for high granularity detectors to reduce the generated data volume. Our simulations considering several parameters (e.g. strip pitch) show that the detector geometry and an electronics parameter of the binary readout chips could be optimized for binary readout to offer an equivalent spatial resolution to the one with an analog readout. To understand the behavior as a function of simulation parameters, we developed analytical models that reproduce simulation results with a few parameters. The models can be used to optimize detector designs and operation conditions with regard to the spatial resolution.

  12. Virtual electrode design for increasing spatial resolution in retinal prosthesis.

    PubMed

    Loizos, Kyle; Cela, Carlos; Marc, Robert; Lazzi, Gianluca

    2016-06-01

    Retinal prostheses systems are currently used to restore partial vision to patients blinded by degenerative diseases by electrically stimulating surviving retinal cells. To obtain likely maximum resolution, electrode size is minimised, allowing for a large quantity on an array and localised stimulation regions. Besides the small size leading to fabrication difficulties and higher electrochemical charge density, there are challenges associated with the number of drivers needed for a large electrode count as well as the strategies to deliver sufficient power to these drivers wirelessly. In hopes to increase electrode resolution while avoiding these issues, the authors propose a new 'virtual electrode' design to increase locations of likely stimulation. Passive metallisation strategically placed between disk electrodes, combined with alternating surrounding stimuli, channel current into a location between electrodes, producing a virtual stimulation site. A computational study was conducted to optimise the passive metal element geometry, quantify the expected current density output, and simulate retinal ganglion cell activity due to virtual electrode stimulation. Results show that this procedure leads to array geometry that focuses injected current and achieves retinal ganglion cell stimulation in a region beneath the 'virtual electrode,' creating an alternate stimulation site without additional drivers. PMID:27382477

  13. Hyperspectral imagery super-resolution by compressive sensing inspired dictionary learning and spatial-spectral regularization.

    PubMed

    Huang, Wei; Xiao, Liang; Liu, Hongyi; Wei, Zhihui

    2015-01-19

    Due to the instrumental and imaging optics limitations, it is difficult to acquire high spatial resolution hyperspectral imagery (HSI). Super-resolution (SR) imagery aims at inferring high quality images of a given scene from degraded versions of the same scene. This paper proposes a novel hyperspectral imagery super-resolution (HSI-SR) method via dictionary learning and spatial-spectral regularization. The main contributions of this paper are twofold. First, inspired by the compressive sensing (CS) framework, for learning the high resolution dictionary, we encourage stronger sparsity on image patches and promote smaller coherence between the learned dictionary and sensing matrix. Thus, a sparsity and incoherence restricted dictionary learning method is proposed to achieve higher efficiency sparse representation. Second, a variational regularization model combing a spatial sparsity regularization term and a new local spectral similarity preserving term is proposed to integrate the spectral and spatial-contextual information of the HSI. Experimental results show that the proposed method can effectively recover spatial information and better preserve spectral information. The high spatial resolution HSI reconstructed by the proposed method outperforms reconstructed results by other well-known methods in terms of both objective measurements and visual evaluation.

  14. Estimation of Orbital Neutron Detector Spatial Resolution by Systematic Shifting of Differential Topographic Masks

    NASA Technical Reports Server (NTRS)

    McClanahan, T. P.; Mitrofanov, I. G.; Boynton, W. V.; Chin, G.; Livengood, T.; Starr, R. D.; Evans, L. G.; Mazarico, E.; Smith, D. E.

    2012-01-01

    We present a method and preliminary results related to determining the spatial resolution of orbital neutron detectors using epithermal maps and differential topographic masks. Our technique is similar to coded aperture imaging methods for optimizing photonic signals in telescopes [I]. In that approach photon masks with known spatial patterns in a telescope aperature are used to systematically restrict incoming photons which minimizes interference and enhances photon signal to noise. Three orbital neutron detector systems with different stated spatial resolutions are evaluated. The differing spatial resolutions arise due different orbital altitudes and the use of neutron collimation techniques. 1) The uncollimated Lunar Prospector Neutron Spectrometer (LPNS) system has spatial resolution of 45km FWHM from approx. 30km altitude mission phase [2]. The Lunar Rennaissance Orbiter (LRO) Lunar Exploration Neutron Detector (LEND) with two detectors at 50km altitude evaluated here: 2) the collimated 10km FWHM spatial resolution detector CSETN and 3) LEND's collimated Sensor for Epithermal Neutrons (SETN). Thus providing two orbital altitudes to study factors of: uncollimated vs collimated and two average altitudes for their effect on fields-of-view.

  15. Full field spatially-variant image-based resolution modelling reconstruction for the HRRT.

    PubMed

    Angelis, Georgios I; Kotasidis, Fotis A; Matthews, Julian C; Markiewicz, Pawel J; Lionheart, William R; Reader, Andrew J

    2015-03-01

    Accurate characterisation of the scanner's point spread function across the entire field of view (FOV) is crucial in order to account for spatially dependent factors that degrade the resolution of the reconstructed images. The HRRT users' community resolution modelling reconstruction software includes a shift-invariant resolution kernel, which leads to transaxially non-uniform resolution in the reconstructed images. Unlike previous work to date in this field, this work is the first to model the spatially variant resolution across the entire FOV of the HRRT, which is the highest resolution human brain PET scanner in the world. In this paper we developed a spatially variant image-based resolution modelling reconstruction dedicated to the HRRT, using an experimentally measured shift-variant resolution kernel. Previously, the system response was measured and characterised in detail across the entire FOV of the HRRT, using a printed point source array. The newly developed resolution modelling reconstruction was applied on measured phantom, as well as clinical data and was compared against the HRRT users' community resolution modelling reconstruction, which is currently in use. Results demonstrated improvements both in contrast and resolution recovery, particularly for regions close to the edges of the FOV, with almost uniform resolution recovery across the entire transverse FOV. In addition, because the newly measured resolution kernel is slightly broader with wider tails, compared to the deliberately conservative kernel employed in the HRRT users' community software, the reconstructed images appear to have not only improved contrast recovery (up to 20% for small regions), but also better noise characteristics.

  16. Full field spatially-variant image-based resolution modelling reconstruction for the HRRT.

    PubMed

    Angelis, Georgios I; Kotasidis, Fotis A; Matthews, Julian C; Markiewicz, Pawel J; Lionheart, William R; Reader, Andrew J

    2015-03-01

    Accurate characterisation of the scanner's point spread function across the entire field of view (FOV) is crucial in order to account for spatially dependent factors that degrade the resolution of the reconstructed images. The HRRT users' community resolution modelling reconstruction software includes a shift-invariant resolution kernel, which leads to transaxially non-uniform resolution in the reconstructed images. Unlike previous work to date in this field, this work is the first to model the spatially variant resolution across the entire FOV of the HRRT, which is the highest resolution human brain PET scanner in the world. In this paper we developed a spatially variant image-based resolution modelling reconstruction dedicated to the HRRT, using an experimentally measured shift-variant resolution kernel. Previously, the system response was measured and characterised in detail across the entire FOV of the HRRT, using a printed point source array. The newly developed resolution modelling reconstruction was applied on measured phantom, as well as clinical data and was compared against the HRRT users' community resolution modelling reconstruction, which is currently in use. Results demonstrated improvements both in contrast and resolution recovery, particularly for regions close to the edges of the FOV, with almost uniform resolution recovery across the entire transverse FOV. In addition, because the newly measured resolution kernel is slightly broader with wider tails, compared to the deliberately conservative kernel employed in the HRRT users' community software, the reconstructed images appear to have not only improved contrast recovery (up to 20% for small regions), but also better noise characteristics. PMID:25596999

  17. Two-photon imaging of spatially extended neuronal network dynamics with high temporal resolution

    PubMed Central

    Lillis, Kyle P.; Eng, Alfred; White, John A.; Mertz, Jerome

    2008-01-01

    We describe a simple two-photon fluorescence imaging strategy, called targeted path scanning (TPS), to monitor the dynamics of spatially extended neuronal networks with high spatiotemporal resolution. Our strategy combines the advantages of mirror-based scanning, minimized dead time, ease of implementation, and compatibility with high-resolution low-magnification objectives. To demonstrate the performance of TPS, we monitor the calcium dynamics distributed across an entire juvenile rat hippocampus (>1.5mm), at scan rates of 100Hz, with single cell resolution and single action potential sensitivity. Our strategy for fast, efficient two-photon microscopy over spatially extended regions provides a particularly attractive solution for monitoring neuronal population activity in thick tissue, without sacrificing the signal to noise ratio or high spatial resolution associated with standard two-photon microscopy. Finally, we provide the code to make our technique generally available. PMID:18539336

  18. Investigating spatial resolutions of imagery for intertidal sediment characterization using geostatistics

    NASA Astrophysics Data System (ADS)

    Ibrahim, Elsy; Adam, Stefanie; De Wever, Aaike; Govaerts, Annelies; Vervoort, Andre; Monbaliu, Jaak

    2014-08-01

    To investigate bio-chemical processes of intertidal sediments, variations in sediment properties such as moisture content, mud content, and chlorophyll a content need to be understood. Remote sensing has been an efficient alternative to traditional data collection methods for such properties. Yet, with the availability of various types of useful sensors, choosing a suitable spatial resolution is challenging, especially that each type has its own cost, availability, and data specifications. This paper investigates the losses in spatial information of sediment properties on the Molenplaat, an intertidal flat on the Western-Scheldt estuary, upon the use of various resolutions. This was carried out using a synergy between remote sensing and geostatistics. The results showed that for the Molenplaat, chlorophyll a content can be well represented by low to medium resolutions. Yet, for moisture and mud content, spatial structures would be lost upon any decrease of resolution from a 4 m×4 m pixel size.

  19. High spatial resolution distributed sensing in optical fibers by Brillouin gain-profile tracing.

    PubMed

    Sperber, Tom; Eyal, Avishay; Tur, Moshe; Thévenaz, Luc

    2010-04-12

    A novel BOTDA technique for distributed sensing of the Brillouin frequency in optical fibers with cm-order spatial resolution is proposed. The technique is based upon a simple modulation scheme, requiring only a single long pump pulse for acoustic excitation, and no subsequent interrogating pulse. Instead, the desired spatial mapping of the Brillouin response is extracted by taking the derivative of the probe signal. As a result, the spatial resolution is limited by the fall-time of the pump modulation, and the phenomena of secondary "echo" signals, typically appearing in BOTDA sensing methods based upon pre-excitation, is mitigated. Experimental demonstration of the detection of a Brillouin frequency variation significantly smaller than the natural Brillouin linewidth, with a 2cm spatial resolution, is presented.

  20. A method for estimating spatial resolution of real image in the Fourier domain.

    PubMed

    Mizutani, Ryuta; Saiga, Rino; Takekoshi, Susumu; Inomoto, Chie; Nakamura, Naoya; Itokawa, Masanari; Arai, Makoto; Oshima, Kenichi; Takeuchi, Akihisa; Uesugi, Kentaro; Terada, Yasuko; Suzuki, Yoshio

    2015-01-01

    Spatial resolution is a fundamental parameter in structural sciences. In crystallography, the resolution is determined from the detection limit of high-angle diffraction in reciprocal space. In electron microscopy, correlation in the Fourier domain is used for estimating the resolution. In this paper, we report a method for estimating the spatial resolution of real images from a logarithmic intensity plot in the Fourier domain. The logarithmic intensity plots of test images indicated that the full width at half maximum of a Gaussian point spread function can be estimated from the images. The spatial resolution of imaging X-ray microtomography using Fresnel zone-plate optics was also estimated with this method. A cross section of a test object visualized with the imaging microtomography indicated that square-wave patterns up to 120-nm pitch were resolved. The logarithmic intensity plot was calculated from a tomographic cross section of brain tissue. The full width at half maximum of the point spread function estimated from the plot coincided with the resolution determined from the test object. These results indicated that the logarithmic intensity plot in the Fourier domain provides an alternative measure of the spatial resolution without explicitly defining a noise criterion.

  1. A method based on covariance and pattern recognition for improving resolutions of spatially encoded NMR spectra.

    PubMed

    Qiu, Wenqi; Chen, Youhe; Wei, Zhiliang; Yang, Jian; Lin, Yulan; Chen, Zhong

    2015-11-01

    The spatially encoded technique enables the fast acquisition of two-dimensional (2D) nuclear magnetic resonance spectrum within a single scan, serving as a powerful tool for studying various systems and phenomena in short time scales. In spatially encoded spectroscopy, the resolution in the direct dimension can be enhanced by increasing effective acquisition times. However, spectral widths and resolutions in indirect dimensions are no longer independent of each other with wider spectral widths yielding lower resolution. The covariance method, which has achieved success in enhancing resolutions in the indirect dimensions of conventional 2D spectroscopy, is employed here to improve resolutions in the spatially encoded dimension. Moreover, an algorithm is developed based on pattern recognition to eliminate artifacts arising from the employment of the covariance method and experimental imperfections in recording the spatially encoded spectra. Therefore, high-resolution homonuclear 2D correlated spectra are obtained. Experiments are performed to show the feasibility and effectiveness of this proposed method in providing high-resolution spectra within greatly shortened times.

  2. SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: Spatial resolution

    SciTech Connect

    Li Dan; Zhao Wei

    2008-07-15

    An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-Se) avalanche photoconductor called high-gain avalanche rushing amorphous photoconductor (HARP). The charge image created by the scintillator/HARP (SHARP) combination is read out by the electron beams emitted from the FEA. The proposed detector is called scintillator avalanche photoconductor with high resolution emitter readout (SAPHIRE). The programmable avalanche gain of HARP can improve the low dose performance of indirect FPI while the FEA can be made with pixel sizes down to 50 {mu}m. Because of the avalanche gain, a high resolution type of CsI (Tl), which has not been widely used in indirect FPI due to its lower light output, can be used to improve the high spatial frequency performance. The purpose of the present article is to investigate the factors affecting the spatial resolution of SAPHIRE. Since the resolution performance of the SHARP combination has been well studied, the focus of the present work is on the inherent resolution of the FEA readout method. The lateral spread of the electron beam emitted from a 50 {mu}mx50 {mu}m pixel FEA was investigated with two different electron-optical designs: mesh-electrode-only and electrostatic focusing. Our results showed that electrostatic focusing can limit the lateral spread of electron beams to within the pixel size of down to 50 {mu}m. Since electrostatic focusing is essentially independent of signal intensity, it will provide excellent spatial uniformity.

  3. Spatial variability of the Black Sea surface temperature from high resolution modeling and satellite measurements

    NASA Astrophysics Data System (ADS)

    Mizyuk, Artem; Senderov, Maxim; Korotaev, Gennady

    2016-04-01

    Large number of numerical ocean models were implemented for the Black Sea basin during last two decades. They reproduce rather similar structure of synoptical variability of the circulation. Since 00-s numerical studies of the mesoscale structure are carried out using high performance computing (HPC). With the growing capacity of computing resources it is now possible to reconstruct the Black Sea currents with spatial resolution of several hundreds meters. However, how realistic these results can be? In the proposed study an attempt is made to understand which spatial scales are reproduced by ocean model in the Black Sea. Simulations are made using parallel version of NEMO (Nucleus for European Modelling of the Ocean). A two regional configurations with spatial resolutions 5 km and 2.5 km are described. Comparison of the SST from simulations with two spatial resolutions shows rather qualitative difference of the spatial structures. Results of high resolution simulation are compared also with satellite observations and observation-based products from Copernicus using spatial correlation and spectral analysis. Spatial scales of correlations functions for simulated and observed SST are rather close and differs much from satellite SST reanalysis. Evolution of spectral density for modelled SST and reanalysis showed agreed time periods of small scales intensification. Using of the spectral analysis for satellite measurements is complicated due to gaps. The research leading to this results has received funding from Russian Science Foundation (project № 15-17-20020)

  4. High spatial resolution 10 micron imaging of IRC + 10216

    NASA Technical Reports Server (NTRS)

    Bloemhof, E. E.; Danchi, W. C.; Townes, C. H.; Mclaren, R. A.

    1988-01-01

    Precise high-resolution 10-micron images of the carbon star IRC + 10216 have been obtained with a scanned linear array. The low noise and high dynamic range of these images permit deconvolution of the telescope point-spread function, revealing the radial brightness distribution of the circumstellar dust shell: approximate reflection symmetry is found in west-east scans, with a distinct division into two components of diameter about 0.40 and 2.2 arcsec. It is shown that this morphology is consistent with published interferometric data that had cast doubt upon an earlier, idealized two-component model. The observed brightness distribution implies that the circumstellar dust density may deviate substantially from the 1/r squared radial dependence expected for spherically symmetric outflow with constant velocity and constant rate of mass loss.

  5. Advanced Extraction of Spatial Information from High Resolution Satellite Data

    NASA Astrophysics Data System (ADS)

    Pour, T.; Burian, J.; Miřijovský, J.

    2016-06-01

    In this paper authors processed five satellite image of five different Middle-European cities taken by five different sensors. The aim of the paper was to find methods and approaches leading to evaluation and spatial data extraction from areas of interest. For this reason, data were firstly pre-processed using image fusion, mosaicking and segmentation processes. Results going into the next step were two polygon layers; first one representing single objects and the second one representing city blocks. In the second step, polygon layers were classified and exported into Esri shapefile format. Classification was partly hierarchical expert based and partly based on the tool SEaTH used for separability distinction and thresholding. Final results along with visual previews were attached to the original thesis. Results are evaluated visually and statistically in the last part of the paper. In the discussion author described difficulties of working with data of large size, taken by different sensors and different also thematically.

  6. On the assessment of spatial resolution of PET systems with iterative image reconstruction.

    PubMed

    Gong, Kuang; Cherry, Simon R; Qi, Jinyi

    2016-03-01

    Spatial resolution is an important metric for performance characterization in PET systems. Measuring spatial resolution is straightforward with a linear reconstruction algorithm, such as filtered backprojection, and can be performed by reconstructing a point source scan and calculating the full-width-at-half-maximum (FWHM) along the principal directions. With the widespread adoption of iterative reconstruction methods, it is desirable to quantify the spatial resolution using an iterative reconstruction algorithm. However, the task can be difficult because the reconstruction algorithms are nonlinear and the non-negativity constraint can artificially enhance the apparent spatial resolution if a point source image is reconstructed without any background. Thus, it was recommended that a background should be added to the point source data before reconstruction for resolution measurement. However, there has been no detailed study on the effect of the point source contrast on the measured spatial resolution. Here we use point source scans from a preclinical PET scanner to investigate the relationship between measured spatial resolution and the point source contrast. We also evaluate whether the reconstruction of an isolated point source is predictive of the ability of the system to resolve two adjacent point sources. Our results indicate that when the point source contrast is below a certain threshold, the measured FWHM remains stable. Once the contrast is above the threshold, the measured FWHM monotonically decreases with increasing point source contrast. In addition, the measured FWHM also monotonically decreases with iteration number for maximum likelihood estimate. Therefore, when measuring system resolution with an iterative reconstruction algorithm, we recommend using a low-contrast point source and a fixed number of iterations.

  7. On the assessment of spatial resolution of PET systems with iterative image reconstruction

    NASA Astrophysics Data System (ADS)

    Gong, Kuang; Cherry, Simon R.; Qi, Jinyi

    2016-03-01

    Spatial resolution is an important metric for performance characterization in PET systems. Measuring spatial resolution is straightforward with a linear reconstruction algorithm, such as filtered backprojection, and can be performed by reconstructing a point source scan and calculating the full-width-at-half-maximum (FWHM) along the principal directions. With the widespread adoption of iterative reconstruction methods, it is desirable to quantify the spatial resolution using an iterative reconstruction algorithm. However, the task can be difficult because the reconstruction algorithms are nonlinear and the non-negativity constraint can artificially enhance the apparent spatial resolution if a point source image is reconstructed without any background. Thus, it was recommended that a background should be added to the point source data before reconstruction for resolution measurement. However, there has been no detailed study on the effect of the point source contrast on the measured spatial resolution. Here we use point source scans from a preclinical PET scanner to investigate the relationship between measured spatial resolution and the point source contrast. We also evaluate whether the reconstruction of an isolated point source is predictive of the ability of the system to resolve two adjacent point sources. Our results indicate that when the point source contrast is below a certain threshold, the measured FWHM remains stable. Once the contrast is above the threshold, the measured FWHM monotonically decreases with increasing point source contrast. In addition, the measured FWHM also monotonically decreases with iteration number for maximum likelihood estimate. Therefore, when measuring system resolution with an iterative reconstruction algorithm, we recommend using a low-contrast point source and a fixed number of iterations.

  8. Practical Considerations for High Spatial and Temporal Resolution Dynamic Transmission Electron Microscopy

    SciTech Connect

    Armstrong, M; Boyden, K; Browning, N D; Campbell, G H; Colvin, J D; DeHope, B; Frank, A M; Gibson, D J; Hartemann, F; Kim, J S; King, W E; LaGrange, T B; Pyke, B J; Reed, B W; Shuttlesworth, R M; Stuart, B C; Torralva, B R

    2006-05-01

    Although recent years have seen significant advances in the spatial resolution possible in the transmission electron microscope (TEM), the temporal resolution of most microscopes is limited to video rate at best. This lack of temporal resolution means that our understanding of dynamic processes in materials is extremely limited. High temporal resolution in the TEM can be achieved, however, by replacing the normal thermionic or field emission source with a photoemission source. In this case the temporal resolution is limited only by the ability to create a short pulse of photoexcited electrons in the source, and this can be as short as a few femtoseconds. The operation of the photo-emission source and the control of the subsequent pulse of electrons (containing as many as 5 x 10{sup 7} electrons) create significant challenges for a standard microscope column that is designed to operate with a single electron in the column at any one time. In this paper, the generation and control of electron pulses in the TEM to obtain a temporal resolution <10{sup -6} s will be described and the effect of the pulse duration and current density on the spatial resolution of the instrument will be examined. The potential of these levels of temporal and spatial resolution for the study of dynamic materials processes will also be discussed.

  9. Spatial resolution of subsurface anthropogenic heat fluxes in cities

    NASA Astrophysics Data System (ADS)

    Benz, Susanne; Bayer, Peter; Menberg, Kathrin; Blum, Philipp

    2015-04-01

    Urban heat islands in the subsurface contain large quantities of energy in the form of elevated groundwater temperatures caused by anthropogenic heat fluxes (AHFS) into the subsurface. Hence, the objective of this study is to exemplarily quantify these AHFS and the generated thermal powers in two German cities, Karlsruhe and Cologne. A two-dimensional (2D) statistical analytical model of the vertical subsurface anthropogenic heat fluxes across the unsaturated zone was developed. The model consists of a so-called Local Monte Carlo approach that introduces a spatial representation of the following sources of AHFS: (1) elevated ground surface temperatures, (2) basements, (3) sewage systems, (4) sewage leakage, (5) subway tunnels, and (6) district heating networks. The results show that district heating networks induce the largest local AHFS with values larger than 60 W/m2 and one order of magnitude higher than the other evaluated heat sources. Only sewage pipes and basements reaching into the groundwater cause equally high heat fluxes, with maximal values of 40.37 W/m2 and 13.60 W/m2, respectively. While dominating locally, the district heating network is rather insignificant for the citywide energy budget in both urban subsurfaces. Heat from buildings (1.51 ± 1.36 PJ/a in Karlsruhe; 0.31 ± 0.14 PJ/a in Cologne) and elevated GST (0.34 ± 0.10 PJ/a in Karlsruhe; 0.42 ± 0.13 PJ/a in Cologne) are dominant contributors to the anthropogenic thermal power of the urban aquifer. In Karlsruhe, buildings are the source of 70% of the annual heat transported into the groundwater, which is mainly caused by basements reaching into the groundwater. A variance analysis confirms these findings: basement depth is the most influential factor to citywide thermal power in the studied cities with high groundwater levels. The spatial distribution of fluxes, however, is mostly influenced by the prevailing thermal gradient across the unsaturated zone. A relatively cold groundwater

  10. Effect of spatial resolution of radar-based inundation maps on the calibration of a spatial inundation model

    NASA Astrophysics Data System (ADS)

    Gobeyn, Sacha; Vernieuwe, Hilde; De Baets, Bernard; Bates, Paul; Verhoest Niko E., C.

    2013-04-01

    With advances in both flood mapping with satellite radar and computational science, the use of real-time spatial flood data holds the potential to support decision making during flood events. With recent improvements in satellite radar technology, current and future radar images are/will be delivered with higher spatial resolution. It is expected that these higher resolutions should improve the accuracy of the calibration and the prediction through data assimilation as more detailed information is available. However, these finer resolution data will result in an increased computational cost. Still, radar data of coarser resolution will remain available, and the question may then arise whether the calibration of a 2D-hydraulic model is significantly influenced by the resolution of the remotely-sensed inundation map. In order to answer this question, the raster-based inundation model, LISFLOOD-FP (Bates et al., 2000) is calibrated using a high resolution synthetic aperture radar image (ERS-2 SAR) of a flood event of the river Dee, Wales, in December 2006. Different radar resolutions are simulated through coarsening this image to different resolutions and retrieving the flood extent maps for the different resolutions. These flood maps are then used for calibrating the hydraulic model using the generalized likelihood uncertainty estimation (GLUE) framework presented by Aronica et al. (2002) as well as alternative calibration methods (e.g. Particle Swarm Optimization, PSO) to assess the possible impact of spatial resolution of the observed flood extent on the floodplain and channel Manning coefficient. Furthermore, the sensitivity of the calibration surface to error sources in radar measurement is evaluated by applying different magnitudes of noise to the radar image. References Aronica, G., Bates, P. D. and Horritt, M. S. (2002). Assessing the uncertainty in distributed model predictions using observed binary pattern information within GLUE. Hydrological Processes, 16

  11. Impact of Spatial Resolution and Forcing on the Simulation of Drought and Floods

    NASA Astrophysics Data System (ADS)

    Melsen, L. A.; Torfs, P. J.; Teuling, R.; Zappa, M.; Mizukami, N.; Clark, M. P.; Uijlenhoet, R.

    2015-12-01

    A Variable Infiltration Capacity (VIC) model for the Thur basin (1703 km2, situated in Switzerland) was set-up and run with four different spatial resolutions (1x1 km, 5x5 km, 10x10 km, lumped) and evaluated at an hourly, daily, and monthly time step. We used the novel Hierarchical Latin Hypercube Sample (HLHS) methodology (Vorechovsky, 2014) to efficiently sample the most sensitive parameters of the VIC model. The model was run 3150 times with the HLHS and the best 10% of the runs based on the NSE(Q) and NSE(logQ) was selected as behavioral and used for further analysis. This whole exercise was conducted both with homogeneously applied forcing (equal precipitation over the whole catchment) and with distributed forcing (specific for each grid cell). We ran the model for the period August 2002 to August 2003. This period is characterised by three very high peaks (August, September 2002) and the 2003 heatwave and associated drought (June, July, August 2003). The 2002 peaks are the highest measured in the past 39 years (1974-2012) at the outlet of the Thur. The peaks were caused by a larger weather system that also caused the heavy floods in the Elbe and the Danube. In contrast, the 2003 summer was extremely warm and dry in Western and Central Europe, with Switzerland being among the hottest and driest regions. For each of the four spatial resolutions we selected the behavioral sets. A large overlap in behavioral sets implies that the model is not very sensitive to spatial resolution. The model was shown not to be very sensitive to spatial resolution if the forcing was applied homogeneously over the catchment, i.e. there was a large overlap in behavioral sets. The model became slightly more sensitive to spatial resolution if the forcing was applied in a distributed fashion. Both for the distributed and for the homogeneously applied forcing the model was shown to be highly sensitive to the temporal resolution, but the sensitivity for temporal resolution decreased with

  12. Impact of spatial resolution on correlation between segmentation evaluation metrics and forest classification accuracy

    NASA Astrophysics Data System (ADS)

    Švab Lenarčič, Andreja; Ritlop, Klemen; Äńurić, Nataša.; Čotar, Klemen; Oštir, Krištof

    2015-10-01

    Slovenia is one of the most forested countries in Europe. Its forest management authorities need information about the forest extent and state, as their responsibility lies in forest observation and preservation. Together with appropriate geographic information system mapping methods the remotely sensed data represent essential tool for an effective and sustainable forest management. Despite the large data availability, suitable mapping methods still present big challenge in terms of their speed which is often affected by the huge amount of data. The speed of the classification method could be maximised, if each of the steps in object-based classification was automated. However, automation is hard to achieve, since segmentation requires choosing optimum parameter values for optimal classification results. This paper focuses on the analysis of segmentation and classification performance and their correlation in a range of segmentation parameter values applied in the segmentation step. In order to find out which spatial resolution is still suitable for forest classification, forest classification accuracies obtained by using four images with different spatial resolutions were compared. Results of this study indicate that all high or very high spatial resolutions are suitable for optimal forest segmentation and classification, as long as appropriate scale and merge parameters combinations are used in the object-based classification. If computation interval includes all segmentation parameter combinations, all segmentation-classification correlations are spatial resolution independent and are generally high. If computation interval includes over- or optimal-segmentation parameter combinations, most segmentation-classification correlations are spatial resolution dependent.

  13. Spatial resolution of a spherical x-ray crystal spectrometer at various magnifications

    NASA Astrophysics Data System (ADS)

    Gao, Lan; Hill, K. W.; Bitter, M.; Efthimion, P. C.; Delgado-Aparicio, L.; Pablant, N. A.; Baronova, E. O.; Pereira, N. R.

    2016-11-01

    A high spatial resolution of a few μm is often required for probing small-scale high-energy-density plasmas using high resolution x-ray imaging spectroscopy. This resolution can be achieved by adjusting system magnification to overcome the inherent limitation of the detector pixel size. Laboratory experiments on investigating the relation between spatial resolution and system magnification for a spherical crystal spectrometer are presented. Tungsten Lβ2 rays from a tungsten-target micro-focus x-ray tube were diffracted by a Ge 440 crystal, which was spherically bent to a radius of 223 mm, and imaged onto an x-ray CCD with 13-μm pixel size. The source-to-crystal (p) and crystal-to-detector (q) distances were varied to produce spatial magnifications (M = q/p) ranging from 2 to 10. The inferred instrumental spatial width reduces with increasing system magnification M. However, the experimental measurement at each M is larger than the theoretical value of pixel size divided by M. Future work will focus on investigating possible broadening mechanisms that limit the spatial resolution.

  14. A comparison of spatial and spectral image resolution for mapping invasive plants in coastal california.

    PubMed

    Underwood, Emma C; Ustin, Susan L; Ramirez, Carlos M

    2007-01-01

    We explored the potential of detecting three target invasive species: iceplant (Carpobrotus edulis), jubata grass (Cortaderia jubata), and blue gum (Eucalyptus globulus) at Vandenberg Air Force Base, California. We compared the accuracy of mapping six communities (intact coastal scrub, iceplant invaded coastal scrub, iceplant invaded chaparral, jubata grass invaded chaparral, blue gum invaded chaparral, and intact chaparral) using four images with different combinations of spatial and spectral resolution: hyperspectral AVIRIS imagery (174 wavebands, 4 m spatial resolution), spatially degraded AVIRIS (174 bands, 30 m), spectrally degraded AVIRIS (6 bands, 4 m), and both spatially and spectrally degraded AVIRIS (6 bands, 30 m, i.e., simulated Landsat ETM data). Overall success rates for classifying the six classes was 75% (kappa 0.7) using full resolution AVIRIS, 58% (kappa 0.5) for the spatially degraded AVIRIS, 42% (kappa 0.3) for the spectrally degraded AVIRIS, and 37% (kappa 0.3) for the spatially and spectrally degraded AVIRIS. A true Landsat ETM image was also classified to illustrate that the results from the simulated ETM data were representative, which provided an accuracy of 50% (kappa 0.4). Mapping accuracies using different resolution images are evaluated in the context of community heterogeneity (species richness, diversity, and percent species cover). Findings illustrate that higher mapping accuracies are achieved with images possessing high spectral resolution, thus capturing information across the visible and reflected infrared solar spectrum. Understanding the tradeoffs in spectral and spatial resolution can assist land managers in deciding the most appropriate imagery with respect to target invasives and community characteristics.

  15. High spatial resolution Land Surface Temperature estimation over urban areas with uncertainty indices

    NASA Astrophysics Data System (ADS)

    Mitraka, Zina; Lazzarini, Michele; Doxani, Georgia; Del Frate, Fabio; Ghedira, Hosni

    2014-05-01

    Land Surface Temperature (LST) is a key variable for studying land surface processes and interactions with the atmosphere and it is listed in the Earth System Data Records (ESDRs) identified by international organizations like Global Climate Observing System. It is a valuable source of information for a range of topics in earth sciences and essential for urban climatology studies. Detailed, frequent and accurate LST mapping may support various urban applications, like the monitoring of urban heat island. Currently, no spaceborne instruments provide frequent thermal imagery at high spatial resolution, thus there is a need for synergistic algorithms that combine different kinds of data for LST retrieval. Moreover, knowing the confidence level of any satellite-derived product is highly important to the users, especially when referred to the urban environment, which is extremely heterogenic. The developed method employs spatial-spectral unmixing techniques for improving the spatial resolution of thermal measurements, combines spectral library information for emissivity estimation and applies a split-window algorithm to estimate LST with an uncertainty estimation inserted in the final product. A synergistic algorithm that utilizes the spatial information provided by visible and near-infrared measurements with more frequent low resolution thermal measurements provides excellent means for high spatial resolution LST estimation. Given the low spatial resolution of thermal infrared sensors, the measured radiation is a combination of radiances of different surface types. High spatial resolution information is used to quantify the different surface types in each pixel and then the measured radiance of each pixel is decomposed. The several difficulties in retrieving LST from space measurements, mainly related to the temperature-emissivity coupling and the atmospheric contribution to the thermal measurements, and the measurements themselves, introduce uncertainties in the final

  16. Using High Spatial Resolution to Improve BOLD fMRI Detection at 3T

    PubMed Central

    Claise, Béatrice; Jean, Betty

    2015-01-01

    For different functional magnetic resonance imaging experiments using blood oxygenation level-dependent (BOLD) contrast, the acquisition of T2*-weighted scans at a high spatial resolution may be advantageous in terms of time-course signal-to-noise ratio and of BOLD sensitivity when the regions are prone to susceptibility artifacts. In this study, we explore this solution by examining how spatial resolution influences activations elicited when appetizing food pictures are viewed. Twenty subjects were imaged at 3 T with two different voxel volumes, 3.4 μl and 27 μl. Despite the diminution of brain coverage, we found that high-resolution acquisition led to a better detection of activations. Though known to suffer to different degrees from susceptibility artifacts, the activations detected by high spatial resolution were notably consistent with those reported in published activation likelihood estimation meta-analyses, corresponding to taste-responsive regions. Furthermore, these regions were found activated bilaterally, in contrast with previous findings. Both the reduction of partial volume effect, which improves BOLD contrast, and the mitigation of susceptibility artifact, which boosts the signal to noise ratio in certain regions, explained the better detection noted with high resolution. The present study provides further evidences that high spatial resolution is a valuable solution for human BOLD fMRI, especially for studying food-related stimuli. PMID:26550990

  17. Interfacial shear stress measurement using high spatial resolution multiphase PIV

    NASA Astrophysics Data System (ADS)

    André, Matthieu A.; Bardet, Philippe M.

    2015-06-01

    In multiphase flows, form drag and viscous shear stress transfer momentum between phases. For numerous environmental and man-made flows, it is of primary importance to predict this transfer at a liquid-gas interface. In its general expression, interfacial shear stress involves local velocity gradients as well as surface velocity, curvature, and surface tension gradients. It is therefore a challenging quantity to measure experimentally or compute numerically. In fact, no experimental work to date has been able to directly resolve all the terms contributing to the shear stress in the case of curved and moving surfaces. In an attempt to fully resolve the interface shear stress when surface tension gradients are negligible, high-resolution particle image velocimetry (PIV) data are acquired simultaneously on both sides of a water-air interface. The flow consists of a well-conditioned uniform and homogeneous water jet discharging in quiescent air, which exhibits two-dimensional surface waves as a result of a shear layer instability below the surface. PIV provides velocity fields in both phases, while planar laser-induced fluorescence is used to track the interface and obtain its curvature. To compute the interfacial shear stress from the data, several processing schemes are proposed and compared, using liquid and/or gas phase data. Vorticity at the surface, which relates to the shear stress through the dynamic boundary condition at the surface, is also computed and provides additional strategies for estimating the shear. The various schemes are in agreement within the experimental uncertainties, validating the methodology for experimentally resolving this demanding quantity.

  18. HIGH SPATIAL RESOLUTION IMAGING OF THERMAL EMISSION FROM DEBRIS DISKS

    SciTech Connect

    Moerchen, Margaret M.; Telesco, Charles M.; Packham, Christopher

    2010-11-10

    We have obtained subarcsecond mid-IR images of a sample of debris disks within 100 pc. For our sample of 19 A-type debris disk candidates chosen for their IR excess, we have resolved, for the first time, five sources plus the previously resolved disk around HD 141569. Two other sources in our sample have been ruled out as debris disks since the time of sample selection. Three of the six resolved sources have inferred radii of 1-4 AU (HD 38678, HD 71155, and HD 181869), and one source has an inferred radius {approx}10-30 AU (HD 141569). Among the resolved sources with detections of excess IR emission, HD 71155 appears to be comparable in size (r {approx} 2 AU) to the solar system's asteroid belt, thus joining {zeta} Lep (HD 38678, reported previously) to comprise the only two resolved sources of that class. Two additional sources (HD 95418 and HD 139006) show spatial extents that imply disk radii of {approx}1-3 AU, although the excess IR fluxes are not formally detected with better than 2{sigma} significance. For the unresolved sources, the upper limits on the maximum radii of mid-IR disk emission are in the range {approx}1-20 AU, four of which are comparable in radius to the asteroid belt. We have compared the global color temperatures of the dust to that expected for the dust in radiative equilibrium at the distances corresponding to the observed sizes or limits on the sizes. In most cases, the temperatures estimated via these two methods are comparable, and therefore, we see a generally consistent picture of the inferred morphology and the global mid-IR emission. Finally, while our sample size is not statistically significant, we note that the older sources (>200 Myr) host much warmer dust (T {approx}> 400 K) than younger sources (in the tens of Myr).

  19. A fast, high spatial resolution optical tomographic scanner for measurement of absorption in gel dosimetry.

    PubMed

    van Doom, T; Bhat, M; Rutten, T P; Tran, T; Costanzo, A

    2005-06-01

    A fast tomographic optical density measurement system has been constructed and evaluated for application in Fricke 3D gel dosimetry. Although the potential for full three-dimensional radiation dosimetry with Fricke gel dosimeters has been extensively reported, its application has been limited due to a lack of fast optical density measurement systems. In this work, the emphasis of the design has been to achieve a short scan time through the use of precision optics and minimal moving parts. The system has been demonstrated in the laboratory to be able to achieve better than 1mm resolution and a scanning time per tomographic slice of 2.4 seconds. Full volumetric sampling of a 10 cm diameter by 7cm long cylinder can be achieved in 3 minutes. When applied with a Fricke based gel dosimeter a linear response between reconstructed CT number and absolute dose was better than 3%.

  20. Direct Imaging of Single Cells and Tissue at Subcellular Spatial Resolution Using Transmission Geometry MALDI MS

    PubMed Central

    Zavalin, Andre; Todd, Erik M.; Rawhouser, Patrick D.; Yang, Junhai; Norris, Jeremy L.; Caprioli, Richard M.

    2012-01-01

    The need of cellular and sub-cellular spatial resolution in LDI / MALDI Imaging Mass Spectrometry (IMS) necessitates micron and sub-micron laser spot sizes at biologically relevant sensitivities, introducing significant challenges for MS technology. To this end we have developed a transmission geometry vacuum ion source that allows the laser beam to irradiate the back side of the sample. This arrangement obviates the mechanical / ion optic complications in the source by completely separating the optical lens and ion optic structures. We have experimentally demonstrated the viability of transmission geometry MALDI MS for imaging biological tissues and cells with sub-cellular spatial resolution. Furthermore, we demonstrate that in conjunction with new sample preparation protocols, the sensitivity of this instrument is sufficient to obtain molecular images at sub-micron spatial resolution. PMID:23147833

  1. Study of spatial resolution of proton computed tomography using a silicon strip detector

    NASA Astrophysics Data System (ADS)

    Saraya, Y.; Izumikawa, T.; Goto, J.; Kawasaki, T.; Kimura, T.

    2014-01-01

    Proton computed tomography (CT) is an imaging technique using a high-energy proton beam penetrating the human body and shows promise for improving the quality of cancer therapy with high-energy particle beams because more accurate electron density distribution measurements can be achieved with proton CT. The deterioration of the spatial resolution owing to multiple Coulomb scattering is, however, a crucial issue. The control of the radiation dose and the long exposure time are also problems to be solved. We have developed a prototype system for proton CT with a silicon strip detector and performed a beam test for imaging. The distribution of the electron density has been measured precisely. We also demonstrated an improvement in spatial resolution by reconstructing the proton trajectory. A spatial resolution of 0.45 mm is achieved for a 25-mm-thick polyethylene object. This will be a useful result for upgrading proton CT application for practical use.

  2. Multimodality hard-x-ray imaging of a chromosome with nanoscale spatial resolution

    DOE PAGES

    Yan, Hanfei; Nazaretski, Evgeny; Lauer, Kenneth R.; Huang, Xiaojing; Wagner, Ulrich; Rau, Christoph; Yusuf, Mohammed; Robinson, Ian K.; Kalbfleisch, Sebastian; Li, Li; et al

    2016-02-05

    Here, we developed a scanning hard x-ray microscope using a new class of x-ray nano-focusing optic called a multilayer Laue lens and imaged a chromosome with nanoscale spatial resolution. The combination of the hard x-ray's superior penetration power, high sensitivity to elemental composition, high spatial-resolution and quantitative analysis creates a unique tool with capabilities that other microscopy techniques cannot provide. Using this microscope, we simultaneously obtained absorption-, phase-, and fluorescence-contrast images of Pt-stained human chromosome samples. The high spatial-resolution of the microscope and its multi-modality imaging capabilities enabled us to observe the internal ultra-structures of a thick chromosome without sectioningmore » it.« less

  3. Multimodality hard-x-ray imaging of a chromosome with nanoscale spatial resolution

    NASA Astrophysics Data System (ADS)

    Yan, Hanfei; Nazaretski, Evgeny; Lauer, Kenneth; Huang, Xiaojing; Wagner, Ulrich; Rau, Christoph; Yusuf, Mohammed; Robinson, Ian; Kalbfleisch, Sebastian; Li, Li; Bouet, Nathalie; Zhou, Juan; Conley, Ray; Chu, Yong S.

    2016-02-01

    We developed a scanning hard x-ray microscope using a new class of x-ray nano-focusing optic called a multilayer Laue lens and imaged a chromosome with nanoscale spatial resolution. The combination of the hard x-ray’s superior penetration power, high sensitivity to elemental composition, high spatial-resolution and quantitative analysis creates a unique tool with capabilities that other microscopy techniques cannot provide. Using this microscope, we simultaneously obtained absorption-, phase-, and fluorescence-contrast images of Pt-stained human chromosome samples. The high spatial-resolution of the microscope and its multi-modality imaging capabilities enabled us to observe the internal ultra-structures of a thick chromosome without sectioning it.

  4. Multimodality hard-x-ray imaging of a chromosome with nanoscale spatial resolution

    PubMed Central

    Yan, Hanfei; Nazaretski, Evgeny; Lauer, Kenneth; Huang, Xiaojing; Wagner, Ulrich; Rau, Christoph; Yusuf, Mohammed; Robinson, Ian; Kalbfleisch, Sebastian; Li, Li; Bouet, Nathalie; Zhou, Juan; Conley, Ray; Chu, Yong S.

    2016-01-01

    We developed a scanning hard x-ray microscope using a new class of x-ray nano-focusing optic called a multilayer Laue lens and imaged a chromosome with nanoscale spatial resolution. The combination of the hard x-ray’s superior penetration power, high sensitivity to elemental composition, high spatial-resolution and quantitative analysis creates a unique tool with capabilities that other microscopy techniques cannot provide. Using this microscope, we simultaneously obtained absorption-, phase-, and fluorescence-contrast images of Pt-stained human chromosome samples. The high spatial-resolution of the microscope and its multi-modality imaging capabilities enabled us to observe the internal ultra-structures of a thick chromosome without sectioning it. PMID:26846188

  5. Agro-hydrology and multi-temporal high-resolution remote sensing: toward an explicit spatial processes calibration

    NASA Astrophysics Data System (ADS)

    Ferrant, S.; Gascoin, S.; Veloso, A.; Salmon-Monviola, J.; Claverie, M.; Rivalland, V.; Dedieu, G.; Demarez, V.; Ceschia, E.; Probst, J.-L.; Durand, P.; Bustillo, V.

    2014-12-01

    The growing availability of high-resolution satellite image series offers new opportunities in agro-hydrological research and modeling. We investigated the possibilities offered for improving crop-growth dynamic simulation with the distributed agro-hydrological model: topography-based nitrogen transfer and transformation (TNT2). We used a leaf area index (LAI) map series derived from 105 Formosat-2 (F2) images covering the period 2006-2010. The TNT2 model (Beaujouan et al., 2002), calibrated against discharge and in-stream nitrate fluxes for the period 1985-2001, was tested on the 2005-2010 data set (climate, land use, agricultural practices, and discharge and nitrate fluxes at the outlet). Data from the first year (2005) were used to initialize the hydrological model. A priori agricultural practices obtained from an extensive field survey, such as seeding date, crop cultivar, and amount of fertilizer, were used as input variables. Continuous values of LAI as a function of cumulative daily temperature were obtained at the crop-field level by fitting a double logistic equation against discrete satellite-derived LAI. Model predictions of LAI dynamics using the a priori input parameters displayed temporal shifts from those observed LAI profiles that are irregularly distributed in space (between field crops) and time (between years). By resetting the seeding date at the crop-field level, we have developed an optimization method designed to efficiently minimize this temporal shift and better fit the crop growth against both the spatial observations and crop production. This optimization of simulated LAI has a negligible impact on water budgets at the catchment scale (1 mm yr-1 on average) but a noticeable impact on in-stream nitrogen fluxes (around 12%), which is of interest when considering nitrate stream contamination issues and the objectives of TNT2 modeling. This study demonstrates the potential contribution of the forthcoming high spatial and temporal resolution

  6. Research on the affect of differential-images technique to the resolution of infrared spatial camera

    NASA Astrophysics Data System (ADS)

    Jin, Guang; An, Yuan; Qi, Yingchun; Hu, Fusheng

    2007-12-01

    The optical system of infrared spatial camera adopts bigger relative aperture and bigger pixel size on focal plane element. These make the system have bulky volume and low resolution. The potential of the optical systems can not be exerted adequately. So, one method for improving resolution of infrared spatial camera based on multi-frame difference-images is introduced in the dissertation. The method uses more than one detectors to acquire several difference images, and then reconstructs a new high-resolution image from these images through the relationship of pixel grey value. The technique of difference-images that uses more than two detectors is researched, and it can improve the resolution 2.5 times in theory. The relationship of pixel grey value between low-resolution difference-images and high-resolution image is found by analyzing the energy of CCD sampling, a general relationship between the enhanced times of the resolution of the detected figure with differential method and the least count of CCD that will be used to detect figure is given. Based on the research of theory, the implementation process of utilizing difference-images technique to improve the resolution of the figure was simulated used Matlab software by taking a personality image as the object, and the software can output the result as an image. The result gotten from the works we have finished proves that the technique is available in high-resolution image reconstruction. The resolution of infrared spatial camera can be improved evidently when holding the size of optical structure or using big size detector by applying for difference image technique. So the technique has a high value in optical remote fields.

  7. Full-field spatially incoherent illumination interferometry: a spatial resolution almost insensitive to aberrations

    NASA Astrophysics Data System (ADS)

    Xiao, Peng; Fink, Mathias; Boccara, A. Claude

    2016-09-01

    We show that with spatially incoherent illumination, the point spread function width of an imaging interferometer like that used in full-field optical coherence tomography (FFOCT) is almost insensitive to aberrations that mostly induce a reduction of the signal level without broadening. This is demonstrated by comparison with traditional scanning OCT and wide-field OCT with spatially coherent illuminations. Theoretical analysis, numerical calculation as well as experimental results are provided to show this specific merit of incoherent illumination in full-field OCT. To the best of our knowledge, this is the first time that such result has been demonstrated.

  8. Evaluating requirements for spatial resolution of fMRI for neurosurgical planning.

    PubMed

    Yoo, Seung-Schik; Talos, Ion-Florin; Golby, Alexandra J; Black, Peter McL; Panych, Lawrence P

    2004-01-01

    The unambiguous localization of eloquent functional areas is necessary to decrease the neurological morbidity of neurosurgical procedures. We explored the minimum spatial resolution requirements for functional magnetic resonance imaging (fMRI) data acquisition when brain mapping is used in neurosurgical planning and navigation. Using a 1.5 Tesla clinical MRI scanner, eight patients with brain tumors underwent fMRI scans using spatial resolution of approximately 4 x 4 x 4 mm(3) to map the eloquent motor and language areas during the performance of cognitive/sensorimotor tasks. The fMRI results were then used intra-operatively in an open MRI system to delineate eloquent areas. Retrospectively, activation patterns were visually inspected by a neurosurgeon to determine qualitatively whether ambiguity with respect to the activation boundaries, due to low spatial resolution, could be of potential significance for surgical guidance. A significant degree of ambiguity in both the extent and shape of activation was judged to be present in data from six of the eight patients. Analysis of fMRI data at multiple resolutions from a normal volunteer showed that at 3 mm isotropic resolution, eloquent areas were better localized within the gray matter although there was still some potential for ambiguity caused by activations appearing to cross a sulcus. The data acquired with 2-mm isotropic voxels significantly enhanced the spatial localization of activation to within the gray matter. Thus, isotropic spatial resolution on the order of 2 x 2 x 2 mm(3), which is much higher than the resolutions used in typical fMRI examinations, may be needed for the unambiguous identification of cortical activation with respect to tumors and important anatomical landmarks.

  9. Fundamental x-ray interaction limits in diagnostic imaging detectors: Spatial resolution

    SciTech Connect

    Hajdok, G.; Battista, J. J.; Cunningham, I. A.

    2008-07-15

    The practice of diagnostic x-ray imaging has been transformed with the emergence of digital detector technology. Although digital systems offer many practical advantages over conventional film-based systems, their spatial resolution performance can be a limitation. The authors present a Monte Carlo study to determine fundamental resolution limits caused by x-ray interactions in four converter materials: Amorphous silicon (a-Si), amorphous selenium, cesium iodide, and lead iodide. The ''x-ray interaction'' modulation transfer function (MTF) was determined for each material and compared in terms of the 50% MTF spatial frequency and Wagner's effective aperture for incident photon energies between 10 and 150 keV and various converter thicknesses. Several conclusions can be drawn from their Monte Carlo study. (i) In low-Z (a-Si) converters, reabsorption of Compton scatter x rays limits spatial resolution with a sharp MTF drop at very low spatial frequencies (<0.3 cycles/mm), especially above 60 keV; while in high-Z materials, reabsorption of characteristic x rays plays a dominant role, resulting in a mid-frequency (1-5 cycles/mm) MTF drop. (ii) Coherent scatter plays a minor role in the x-ray interaction MTF. (iii) The spread of energy due to secondary electron (e.g., photoelectrons) transport is significant only at very high spatial frequencies. (iv) Unlike the spread of optical light in phosphors, the spread of absorbed energy from x-ray interactions does not significantly degrade spatial resolution as converter thickness is increased. (v) The effective aperture results reported here represent fundamental spatial resolution limits of the materials tested and serve as target benchmarks for the design and development of future digital x-ray detectors.

  10. Large-scale proton radiography with micrometer spatial resolution using femtosecond petawatt laser system

    SciTech Connect

    Wang, W. P.; Shen, B. F. Zhang, H.; Lu, X. M.; Wang, C.; Liu, Y. Q.; Yu, L. H.; Chu, Y. X.; Li, Y. Y.; Xu, T. J.; Zhang, H.; Zhai, S. H.; Leng, Y. X.; Liang, X. Y.; Li, R. X.; Xu, Z. Z.

    2015-10-15

    An image of dragonfly with many details is obtained by the fundamental property of the high-energy proton source on a femtosecond petawatt laser system. Equal imaging of the dragonfly and high spatial resolution on the micrometer scale are simultaneously obtained. The head, wing, leg, tail, and even the internal tissue structures are clearly mapped in detail by the proton beam. Experiments show that image blurring caused by multiple Coulomb scattering can be reduced to a certain extent and the spatial resolution can be increased by attaching the dragonfly to the RCFs, which is consistent with theoretical assumptions.

  11. Spatial resolution of tip-enhanced Raman spectroscopy - DFT assessment of the chemical effect.

    PubMed

    Latorre, Federico; Kupfer, Stephan; Bocklitz, Thomas; Kinzel, Daniel; Trautmann, Steffen; Gräfe, Stefanie; Deckert, Volker

    2016-05-21

    Experimental evidence of extremely high spatial resolution of tip-enhanced Raman scattering (TERS) has been recently demonstrated. Here, we present a full quantum chemical description (at the density functional level of theory) of the non-resonant chemical effects on the Raman spectrum of an adenine molecule mapped by a tip, modeled as a single silver atom or a small silver cluster. We show pronounced changes in the Raman pattern and its intensities depending on the conformation of the nanoparticle-substrate system, concluding that the spatial resolution of the chemical contribution of TERS can be in the sub-nm range.

  12. Ultrafast laser induced breakdown spectroscopy for high spatial resolution chemical analysis

    NASA Astrophysics Data System (ADS)

    Zorba, Vassilia; Mao, Xianglei; Russo, Richard E.

    2011-02-01

    Femtosecond laser induced breakdown spectroscopy (LIBS) was used to identify the spatial resolution limitations and assess the minimal detectable mass restrictions in laser-ablation based chemical analysis. The atomic emission of sodium (Na) and potassium (K) dopants in transparent dielectric Mica matrices was studied, to find that both these elements could be detected from 450 nm diameter ablation craters, full-width-at-half-maximum (FWHM). Under optimal conditions, mass as low as 220 ag was measured, demonstrating the feasibility of using laser-ablation based chemical analysis to achieve high spatial resolution elemental analysis in real-time and at atmospheric pressure conditions.

  13. Iterative algorithm for reconstructing rotationally asymmetric surface deviation with pixel-level spatial resolution

    NASA Astrophysics Data System (ADS)

    Quan, Haiyang; Wu, Fan; Hou, Xi

    2015-10-01

    New method for reconstructing rotationally asymmetric surface deviation with pixel-level spatial resolution is proposed. It is based on basic iterative scheme and accelerates the Gauss-Seidel method by introducing an acceleration parameter. This modified Successive Over-relaxation (SOR) is effective for solving the rotationally asymmetric components with pixel-level spatial resolution, without the usage of a fitting procedure. Compared to the Jacobi and Gauss-Seidel method, the modified SOR method with an optimal relaxation factor converges much faster and saves more computational costs and memory space without reducing accuracy. It has been proved by real experimental results.

  14. Magnetoacoustic Imaging of Electrical Conductivity of Biological Tissues at a Spatial Resolution Better than 2 mm

    PubMed Central

    Hu, Gang; He, Bin

    2011-01-01

    Magnetoacoustic tomography with magnetic induction (MAT-MI) is an emerging approach for noninvasively imaging electrical impedance properties of biological tissues. The MAT-MI imaging system measures ultrasound waves generated by the Lorentz force, having been induced by magnetic stimulation, which is related to the electrical conductivity distribution in tissue samples. MAT-MI promises to provide fine spatial resolution for biological tissue imaging as compared to ultrasound resolution. In the present study, we first estimated the imaging spatial resolution by calculating the full width at half maximum (FWHM) of the system point spread function (PSF). The actual spatial resolution of our MAT-MI system was experimentally determined to be 1.51 mm by a parallel-line-source phantom with Rayleigh criterion. Reconstructed images made from tissue-mimicking gel phantoms, as well as animal tissue samples, were consistent with the morphological structures of the samples. The electrical conductivity value of the samples was determined directly by a calibrated four-electrode system. It has been demonstrated that MAT-MI is able to image the electrical impedance properties of biological tissues with better than 2 mm spatial resolution. These results suggest the potential of MAT-MI for application to early detection of small-size diseased tissues (e.g. small breast cancer). PMID:21858111

  15. The study on spatial resolution in two-photon induced polymerization

    NASA Astrophysics Data System (ADS)

    Takada, Kenji; Sun, Hong-Bo; Kawata, Satoshi

    2006-01-01

    We have previously demonstrated that two-photon induced polymerization allows fabrication of complex threedimensional structures such as photonic crystals and micromachines with a spatial resolution around 120 nm. In this report, we show the resolution improvement till 65 nm. Experimentally, 780-nm femtosecond laser pulses were focused into a photopolymerizable resin by a high numerical aperture objective lens. The resin is polymerized by means of radical initiation. In the radical polymerization, oxygen molecules dissolved in the resin inhibit the polymerization reactions by scavenging the radicals that initiate the polymerization. At controlled laser pulse energy, the radicals can survive and initiate polymerization only at the region where exposure energy is larger than the polymerization threshold, leading to a sub-diffraction-limited spatial resolution. In order to further improve the fabrication accuracy, we introduced a radical quencher into the resin, and at an optimized concentration the lateral spatial resolution was improved to 100 nm. Moreover, we fabricated a suspended fiber connected between two anchors by controlling the exposure dose within the fiber. After removing the unsolidified resin by ethanol and drying, a 65-nm width fiber was obtained, suggesting a possible spatial resolution of similar dimension. The size less than 1/10 of the excitation wavelength could satisfy requirements of many photonic and optoelectronic devices.

  16. High-resolution observations of the spatial and velocity distribution of cometary hydrogen

    NASA Technical Reports Server (NTRS)

    Brown, Michael E.; Spinrad, Hyron

    1992-01-01

    We have obtained high velocity and spatial resolution long-slit H alpha spectra of comets Austin (1989c1) and Levy (1990c). Spectra of both comets clearly show the existence of a low velocity thermalized component of hydrogen gas. The amount of slow hydrogen is estimated for comet Austin. The Levy spectrum shows an unusual high-velocity spatially-confined blob of hydrogen emission of unknown origin.

  17. Spatial perception of sound fields recorded by spherical microphone arrays with varying spatial resolution.

    PubMed

    Avni, Amir; Ahrens, Jens; Geier, Matthias; Spors, Sascha; Wierstorf, Hagen; Rafaely, Boaz

    2013-05-01

    The area of sound field synthesis has significantly advanced in the past decade, facilitated by the development of high-quality sound-field capturing and re-synthesis systems. Spherical microphone arrays are among the most recently developed systems for sound field capturing, enabling processing and analysis of three-dimensional sound fields in the spherical harmonics domain. In spite of these developments, a clear relation between sound fields recorded by spherical microphone arrays and their perception with a re-synthesis system has not yet been established, although some relation to scalar measures of spatial perception was recently presented. This paper presents an experimental study of spatial sound perception with the use of a spherical microphone array for sound recording and headphone-based binaural sound synthesis. Sound field analysis and processing is performed in the spherical harmonics domain with the use of head-related transfer functions and simulated enclosed sound fields. The effect of several factors, such as spherical harmonics order, frequency bandwidth, and spatial sampling, are investigated by applying the repertory grid technique to the results of the experiment, forming a clearer relation between sound-field capture with a spherical microphone array and its perception using binaural synthesis regarding space, frequency, and additional artifacts. The experimental study clearly shows that a source will be perceived more spatially sharp and more externalized when represented by a binaural stimuli reconstructed with a higher spherical harmonics order. This effect is apparent from low spherical harmonics orders. Spatial aliasing, as a result of sound field capturing with a finite number of microphones, introduces unpleasant artifacts which increased with the degree of aliasing error.

  18. Optimal Spatial Resolution of Omnidirectional Imaging Systems for Pipe Inspection Applications

    NASA Astrophysics Data System (ADS)

    Dehghan Tezerjani, Abbasali; Mehrandezh, Mehran; Paranjape, Raman

    2015-10-01

    Achieving optimal spatial resolution in imaging systems plays a major role in the design of vision-based industrial inspection tools. Single-view omnidirectional imaging systems provide a cost-effective and computationally-traceable solution for real-time inspection of infrastructure with a favorable size factor. We formulate, for the first time, the spatial cylindrical resolution of omnidirectional Catadioptric and Dioptric imaging systems with the focus on pipe inspection applications. We also provide a design guideline to achieve the highest resolution in these systems. First, we deliver a comprehensive study on optimal resolution in Catadioptric imaging systems which consist of a perspective pinhole camera, a collimated laser as the light source, and a reflective surface (i.e., hyperbolic mirror). Variation of the spatial resolution in terms of the camera's focal length, the mirror curvature, and the relative position between the laser projector and the camera is fully investigated via simulation and experiments. Also, the optimal resolution in Dioptric systems, which consist of a camera with compound refractive lenses (i.e., fish-eye lens) is studied and compared with that in Catadioptric systems. Tests were conducted on a 40-cm-diameter PVC pipe in a controlled laboratory environment.

  19. High spatial resolution upgrade of the electron cyclotron emission radiometer for the DIII-D tokamak.

    PubMed

    Truong, D D; Austin, M E

    2014-11-01

    The 40-channel DIII-D electron cyclotron emission (ECE) radiometer provides measurements of Te(r,t) at the tokamak midplane from optically thick, second harmonic X-mode emission over a frequency range of 83-130 GHz. The frequency spacing of the radiometer's channels results in a spatial resolution of ∼1-3 cm, depending on local magnetic field and electron temperature. A new high resolution subsystem has been added to the DIII-D ECE radiometer to make sub-centimeter (0.6-0.8 cm) resolution Te measurements. The high resolution subsystem branches off from the regular channels' IF bands and consists of a microwave switch to toggle between IF bands, a switched filter bank for frequency selectivity, an adjustable local oscillator and mixer for further frequency down-conversion, and a set of eight microwave filters in the 2-4 GHz range. Higher spatial resolution is achieved through the use of a narrower (200 MHz) filter bandwidth and closer spacing between the filters' center frequencies (250 MHz). This configuration allows for full coverage of the 83-130 GHz frequency range in 2 GHz bands. Depending on the local magnetic field, this translates into a "zoomed-in" analysis of a ∼2-4 cm radial region. Expected uses of these channels include mapping the spatial dependence of Alfven eigenmodes, geodesic acoustic modes, and externally applied magnetic perturbations. Initial Te measurements, which demonstrate that the desired resolution is achieved, are presented.

  20. Design and performance of a high spatial resolution, time-of-flight PET detector

    PubMed Central

    Krishnamoorthy, Srilalan; LeGeyt, Benjamin; Werner, Matthew E.; Kaul, Madhuri; Newcomer, F. M.; Karp, Joel S.; Surti, Suleman

    2014-01-01

    This paper describes the design and performance of a high spatial resolution PET detector with time-of-flight capabilities. With an emphasis on high spatial resolution and sensitivity, we initially evaluated the performance of several 1.5 × 1.5 and 2.0 × 2.0 mm2 and 12–15 mm long LYSO crystals read out by several appropriately sized PMTs. Experiments to evaluate the impact of reflector on detector performance were performed and the final detector consisted of a 32 × 32 array of 1.5 × 1.5 × 15 mm3 LYSO crystals packed with a diffuse reflector and read out by a single Hamamatsu 64 channel multi-anode PMT. Such a design made it compact, modular and offered a cost-effective solution to obtaining excellent energy and timing resolution. To minimize the number of readout signals, a compact front-end readout electronics that summed anode signals along each of the orthogonal directions was also developed. Experimental evaluation of detector performance demonstrates clear discrimination of the crystals within the detector. An average energy resolution (FWHM) of 12.7 ± 2.6% and average coincidence timing resolution (FWHM) of 348 ps was measured, demonstrating suitability for use in the development of a high spatial resolution time-of-flight scanner for dedicated breast PET imaging. PMID:25246711

  1. Displaying a high-resolution digital hologram on a low-resolution spatial light modulator with the same resolution obtained from the hologram.

    PubMed

    Tsang, P W M; Poon, T-C; Zhou, C

    2013-07-29

    In this paper, a fast method for displaying a digital, real and off-axis Fresnel hologram on a lower resolution device is reported. Preserving the original resolution of the hologram upon display is one of the important attributes of the proposed method. Our method can be divided into 3 stages. First, a digital hologram representing a given three dimensional (3D) object is down-sampled based on a fix, jitter down-sampling lattice. Second, the down-sampled hologram is interpolated, through pixel duplication, into a low resolution hologram that can be displayed with a low-resolution spatial light modulator (SLM). Third, the SLM is overlaid with a grating which is generated based on the same jitter down-sampling lattice that samples the hologram. The integration of the grating and the low-resolution hologram results in, to a good approximation, the resolution of the original hologram. As such, our proposed method enables digital holograms to be displayed with lower resolution SLMs, paving the way for the development of low-cost holographic video display.

  2. Dark filaments observed at 8.3mm and 3.1mm wavelength

    NASA Technical Reports Server (NTRS)

    Hiel, E.; Ishiguro, M.; Kosugi, T.; Shibasaki, K.

    1986-01-01

    Mapping of the sun was made at 3.1mm (98 GHz) and 8.3mm (36 GHz) wavelengths with a 45m dish radio telescope at the Nobeyama Cosmic Radio Observatory. The depressions associated with large H alpha filaments are derived to be -0.2 at 8.3mm and -0.05 at 3.1mm, which are darker than the values inferred by Raoult et al. (1979)

  3. On the sensitivity of urban hydrodynamic modelling to rainfall spatial and temporal resolution

    NASA Astrophysics Data System (ADS)

    Bruni, G.; Reinoso, R.; van de Giesen, N. C.; Clemens, F. H. L. R.; ten Veldhuis, J. A. E.

    2015-02-01

    Cities are increasingly vulnerable to floods generated by intense rainfall, because of urbanisation of flood-prone areas and ongoing urban densification. Accurate information of convective storm characteristics at high spatial and temporal resolution is a crucial input for urban hydrological models to be able to simulate fast runoff processes and enhance flood prediction in cities. In this paper, a detailed study of the sensitivity of urban hydrodynamic response to high resolution radar rainfall was conducted. Rainfall rates derived from X-band dual polarimetric weather radar were used as input into a detailed hydrodynamic sewer model for an urban catchment in the city of Rotterdam, the Netherlands. The aim was to characterise how the effect of space and time aggregation on rainfall structure affects hydrodynamic modelling of urban catchments, for resolutions ranging from 100 to 2000 m and from 1 to 10 min. Dimensionless parameters were derived to compare results between different storm conditions and to describe the effect of rainfall spatial resolution in relation to storm characteristics and hydrodynamic model properties: rainfall sampling number (rainfall resolution vs. storm size), catchment sampling number (rainfall resolution vs. catchment size), runoff and sewer sampling number (rainfall resolution vs. runoff and sewer model resolution respectively). Results show that for rainfall resolution lower than half the catchment size, rainfall volumes mean and standard deviations decrease as a result of smoothing of rainfall gradients. Moreover, deviations in maximum water depths, from 10 to 30% depending on the storm, occurred for rainfall resolution close to storm size, as a result of rainfall aggregation. Model results also showed that modelled runoff peaks are more sensitive to rainfall resolution than maximum in-sewer water depths as flow routing has a damping effect on in-sewer water level variations. Temporal resolution aggregation of rainfall inputs led to

  4. Improvement of spatial resolution in confocal microscope with shifted-focus phase filter

    NASA Astrophysics Data System (ADS)

    Huang, Xiangdong; Xiang, Xiaoyan; Wang, Chongyang

    2015-02-01

    A spatial super-resolution method is proposed based on the multiplicative character of confocal microscope's amplitude point-spread functions. The axial resolution can be greatly improved by introducing a shifted-focus phase filters in illumination part of a confocal microscope. However, this improvement is accompanied by a decrease of transversal resolution. Thus, a super-Gaussian phase filter is optimized to control the focal shift and transversal intensity distribution in a confocal microscope. Numerical simulation results indicate that the proposed method is useful to obtain a significant improvement in the optical sectioning capacity.

  5. The Sun at high spatial resolution: The physics of small spatial structures in a magnetized medium

    NASA Technical Reports Server (NTRS)

    Rosner, R. T.

    1986-01-01

    An attempt is made to provide a perspective on the problem of spatial structuring on scales smaller than can presently be directly and regularly observed from the ground or with which current space-based instrumentation can be anticipated. There is abundant evidence from both observations and theory that such spatial structuring of the solar outer atmosphere is ubiquitous not only on the observed scales, but also on spatial scales down to (at least) the subarcsecond range. This is not to say that the results to be obtained from observations on these small scales can be anticipated: quite the opposite. What is clear instead is that many of the classic problems of coronal and chromospheric activity - involving the basic dissipative nature of magnetized plasmas - will be seen from a novel perspective at these scales, and that there are reasons for believing that dynamical processes of importance to activity on presently-resolved scales will themselves begin to be resolved on the sub-arcsecond level. Since the Sun is the only astrophysical laboratory for which there is any hope of studying these processes in any detail, this observatioinal opportunity is an exciting prospect for any student of magnetic activity in astrophysics.

  6. Resolution and Brightness Characteristics of Short-Lag Spatial Coherence (SLSC) Images

    PubMed Central

    Lediju Bell, Muyinatu A.; Dahl, Jeremy J.; Trahey, Gregg E.

    2016-01-01

    We previously described a novel beamforming method that images the spatial correlation of an echo wave field with demonstrated applications to clutter reduction in high-noise environments. In this paper, several characteristics of the resolution and brightness of short-lag spatial coherence (SLSC) images formed by this method are compared with B-mode images formed by conventional delay-and-sum beamforming methods. Point target widths were measured to estimate resolution, the autocorrelation of image texture was measured to estimate texture size, and the contrast (i.e., brightness ratio) of clinically relevant targets was assessed. SLSC images demonstrate improved resolution and contrast with increasing values of channel noise and clutter, whereas B-mode resolution was degraded in the presence of high noise (i.e., > −12 dB channel noise-to-signal ratios) and high clutter magnitudes (i.e., > −21 dB relative to point target magnitude). Lateral resolution in SLSC images was improved with increasing lag value, whereas axial resolution was degraded with increasing correlation kernel length. The texture size of SLSC images was smaller than that of matched B-mode images. Results demonstrate that the resolution and contrast of coherence-based images depend on a range of parameters, but are generally superior to those of matched B-mode images under challenging imaging conditions. PMID:26168173

  7. Implementation of soft x-ray microscopy with several tens nanometers spatial resolution at NSRL

    NASA Astrophysics Data System (ADS)

    Jiang, Shiping; Chen, Liang

    2009-09-01

    A transmission soft x-ray microscope (TXM), which is similar to the full-field x-ray microscopes installed on other synchrotron radiation sources in the world, was developed at National Synchrotron Radiation Laboratory (NSRL) in Hefei. An x-ray image taken with the microscope was acquired and its spatial resolution was estimated to be better than 70nm.

  8. High spatial resolution X-ray and gamma ray imaging system using diffraction crystals

    DOEpatents

    Smither, Robert K.

    2011-05-17

    A method and a device for high spatial resolution imaging of a plurality of sources of x-ray and gamma-ray radiation are provided. The device comprises a plurality of arrays, with each array comprising a plurality of elements comprising a first collimator, a diffracting crystal, a second collimator, and a detector.

  9. Spatial resolution of tip-enhanced Raman spectroscopy - DFT assessment of the chemical effect

    NASA Astrophysics Data System (ADS)

    Latorre, Federico; Kupfer, Stephan; Bocklitz, Thomas; Kinzel, Daniel; Trautmann, Steffen; Gräfe, Stefanie; Deckert, Volker

    2016-05-01

    Experimental evidence of extremely high spatial resolution of tip-enhanced Raman scattering (TERS) has been recently demonstrated. Here, we present a full quantum chemical description (at the density functional level of theory) of the non-resonant chemical effects on the Raman spectrum of an adenine molecule mapped by a tip, modeled as a single silver atom or a small silver cluster. We show pronounced changes in the Raman pattern and its intensities depending on the conformation of the nanoparticle-substrate system, concluding that the spatial resolution of the chemical contribution of TERS can be in the sub-nm range.Experimental evidence of extremely high spatial resolution of tip-enhanced Raman scattering (TERS) has been recently demonstrated. Here, we present a full quantum chemical description (at the density functional level of theory) of the non-resonant chemical effects on the Raman spectrum of an adenine molecule mapped by a tip, modeled as a single silver atom or a small silver cluster. We show pronounced changes in the Raman pattern and its intensities depending on the conformation of the nanoparticle-substrate system, concluding that the spatial resolution of the chemical contribution of TERS can be in the sub-nm range. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00093b

  10. MODIS aerosol product at 3 km spatial resolution for urban and air quality studies

    NASA Astrophysics Data System (ADS)

    Mattoo, S.; Remer, L. A.; Levy, R. C.; Holben, B. N.; Smirnov, A.

    2008-12-01

    The MODerate resolution Imaging Spectroradiometer (MODIS) aboard the Terra and Aqua satellites has been producing an aerosol product since early 2000. The original product reports aerosol optical depth and a variety of other aerosol parameters at a spatial resolution of 10 km over both land and ocean. The 10 km product is actually constructed from 500 m pixels, which permits a strict selection process to choose the "best" or "cleanest" pixels in each 10 km square for use in the aerosol retrieval. Thus, the original 10 km product provides a useful product, accurate in many applications. However, the 10 km product can miss narrow aerosol plumes and the spatial variability associated with urban air pollution. The MODIS aerosol team will be introducing a finer resolution aerosol product over land regions in the next release of the product (Collection 6). The new product will be produced at 3 km resolution. It is based on the same procedures as the original product and benefits from the same spatial variability criteria for finding and masking cloudy pixels. The 3 km product does capture the higher spatial variability associated with individual aerosol plumes. However, it is noisier than the 10 km product. Both products will be available operationally in Collection 6. The new 3km product offers new synergistic possibilities with PM2.5 monitoring networks, AERONET and various air quality models such as CMAQ.

  11. Improving the quantification at high spatial resolution using a field emission electron microprobe

    NASA Astrophysics Data System (ADS)

    Pinard, P. T.; Richter, S.

    2014-03-01

    The capabilities of field emitter electron microprobes to perform quantitative measurements at high spatial resolution are discussed. Using Fe-Cr-C particles in a bearing steel (SAE 52100) as example, a generic procedure was established to find the optimal analytical conditions (beam energy, beam current and acquisition time). The influence of these parameters on the accuracy, precision and spatial resolution was evaluated using experimental measurements and Monte Carlo simulations. A quantification procedure was developed for soft X-ray lines, taking into account the overlap of high order X-ray lines and background anomalies. The accuracy of Ka- and La-lines was verified using reference materials. A relationship between experimental and simulated X-ray intensities was determined to evaluate the measurement precision. The spatial resolution of each X-ray line was calculated from the simulated lateral and depth X-ray intensity distribution using simulations integrating experimentally measured beam diameters. The optimal analytical conditions for the studied sample were found to be 5 keV, 10 nA and 10 s acquisition time. Further specialized techniques to improve the spatial resolution are presented: focused ion beam preparation of thin lamella and wedge, and Monte Carlo based reconstruction. The feasibility of the latter to quantify features smaller than the X-ray emission volume was demonstrated.

  12. A system for optically controlling neural circuits with very high spatial and temporal resolution

    PubMed Central

    Pandarinath, Chethan; Carlson, Eric T.; Nirenberg, Sheila

    2015-01-01

    Optogenetics offers a powerful new approach for controlling neural circuits. It has a vast array of applications in both basic and clinical science. For basic science, it opens the door to unraveling circuit operations, since one can perturb specific circuit components with high spatial (single cell) and high temporal (millisecond) resolution. For clinical applications, it allows new kinds of selective treatments, because it provides a method to inactivate or activate specific components in a malfunctioning circuit and bring it back into a normal operating range [1–3]. To harness the power of optogenetics, though, one needs stimulating tools that work with the same high spatial and temporal resolution as the molecules themselves, the channelrhodopsins. To date, most stimulating tools require a tradeoff between spatial and temporal precision and are prohibitively expensive to integrate into a stimulating/recording setup in a laboratory or a device in a clinical setting [4, 5]. Here we describe a Digital Light Processing (DLP)-based system capable of extremely high temporal resolution (sub-millisecond), without sacrificing spatial resolution. Furthermore, it is constructed using off-the-shelf components, making it feasible for a broad range of biology and bioengineering labs. Using transgenic mice that express channelrhodopsin-2 (ChR2), we demonstrate the system’s capability for stimulating channelrhodopsin-expressing neurons in tissue with single cell and sub-millisecond precision. PMID:25699292

  13. Real space soft x-ray imaging at 10 nm spatial resolution

    SciTech Connect

    Chao, Weilun; Fischer, Peter; Tyliszczak, T.; Rekawa, Senajith; Anderson, Erik; Naulleau, Patrick

    2011-04-24

    Using Fresnel zone plates made with our robust nanofabrication processes, we have successfully achieved 10 nm spatial resolution with soft x-ray microscopy. The result, obtained with both a conventional full-field and scanning soft x-ray microscope, marks a significant step forward in extending the microscopy to truly nanoscale studies.

  14. Scaling field data to calibrate and validate moderate spatial resolution remote sensing models

    USGS Publications Warehouse

    Baccini, A.; Friedl, M.A.; Woodcock, C.E.; Zhu, Z.

    2007-01-01

    Validation and calibration are essential components of nearly all remote sensing-based studies. In both cases, ground measurements are collected and then related to the remote sensing observations or model results. In many situations, and particularly in studies that use moderate resolution remote sensing, a mismatch exists between the sensor's field of view and the scale at which in situ measurements are collected. The use of in situ measurements for model calibration and validation, therefore, requires a robust and defensible method to spatially aggregate ground measurements to the scale at which the remotely sensed data are acquired. This paper examines this challenge and specifically considers two different approaches for aggregating field measurements to match the spatial resolution of moderate spatial resolution remote sensing data: (a) landscape stratification; and (b) averaging of fine spatial resolution maps. The results show that an empirically estimated stratification based on a regression tree method provides a statistically defensible and operational basis for performing this type of procedure. 

  15. Beam hardening correction for a cone-beam CT system and its effect on spatial resolution

    NASA Astrophysics Data System (ADS)

    Zhao, Wei; Fu, Guo-Tao; Sun, Cui-Li; Wang, Yan-Fang; Wei, Cun-Feng; Cao, Da-Quan; Que, Jie-Min; Tang, Xiao; Shi, Rong-Jian; Wei, Long; Yu, Zhong-Qiang

    2011-10-01

    In this paper, we present a beam hardening correction (BHC) method in three-dimension space for a cone-beam computed tomography (CBCT) system in a mono-material case and investigate its effect on the spatial resolution. Due to the polychromatic character of the X-ray spectrum used, cupping and streak artifacts called beam hardening artifacts arise in the reconstructed CT images, causing reduced image quality. In addition, enhanced edges are introduced in the reconstructed CT images because of the beam hardening effect. The spatial resolution of the CBCT system is calculated from the edge response function (ERF) on different planes in space. Thus, in the CT images with beam hardening artifacts, enhanced ERFs will be extracted to calculate the modulation transfer function (MTF), obtaining a better spatial resolution that deviates from the real value. Reasonable spatial resolution can be obtained after reducing the artifacts. The 10% MTF value and the full width at half maximum (FWHM) of the point spread function with and without BHC are presented.

  16. Effects of lead spatial resolution on the spectrum of cardiac signals: a simulation study.

    PubMed

    Beltrán-Molina, F; Muñoz-Gómez, A; Rodríguez, A B; Vinagre, J J; Requena--Carrión, J

    2011-01-01

    Spectral analysis is widely applied to bioelectric cardiac signals for quantifying the spatiotemporal organization of cardiac tissue. Nevertheless, to date it is not well understood how lead characteristics affect the spectrum of recorded cardiac signals and, as a consequence, the interpretation of cardiac spectrum is still controversial. In this paper we use simulation methods to investigate the effects of lead spatial resolution on the spectrum of cardiac signals. We simulate three cardiac rhythms of different degrees of spatiotemporal organization in a square sample of cardiac tissue. Then, by using a lead field approach, we synthesize the signals recorded by four idealized leads of different spatial resolution. Finally, we estimate the spectrum of simulated cardiac signals. Our simulations indicate that lead spatial resolution affects cardiac spectrum, although the effects depend on the organization of the underlying rhythm. Specifically, our simulations show that for highly organized rhythms, the smaller the lead resolution region, the broader the distribution of power in frequency. Since lead resolution can affect significantly cardiac spectrum, we conclude that caution should be used when quantifying cardiac spatiotemporal organization based on the spectrum of cardiac signals. PMID:22255167

  17. Spatial Resolution and Catchment Size Interaction of Soil Hydrological Properties for Hydrological Modeling

    NASA Astrophysics Data System (ADS)

    Libohova, Zamir; Bowling, Laura C.; Owens, Phillip R.; Schoeneberger, Philip; Wysocki, Douglas; Wills, Skye; Lindbo, David

    2016-04-01

    Spatial resolution of soil hydrologic properties is critical for distributed hydrological model streamflow simulations. Soils from US Soil Survey Geographic (SSURGO) Database are mapped at scales varying from 1:12,000 to 65,000. Related to these scales are also soil hydrological properties, which could vary spatially outside of the common SSURGO scale range. The objective of this research was to assess the role of the spatial resolution of soil depth on simulated hydrological response for various watershed sizes using the Distributed Hydrology Soil Vegetation Model (DHSVM). The study site was Hall Creek watershed a 56 km2 in size located in Dubois County in southern Indiana, USA. The watershed size was divided in 55 sub-watersheds varying in size from less than 5 km2 to 56 km2. The grid size spatial resolution of soil hydrological properties varied from 10x10, 30x30 and 90x90m. The simulated streamflow metrics were annual mean, minimum and maximum streamflow, and R-B Flashiness, which measures the variability in streamflow between successive days highlighting the fluctuation of discharge relative to total discharge. The slopes of the regression of simulated stream discharge parameters versus watershed size were used to assess the presence of interaction. In addition, the coefficient of variation was used to assess the variability for the R-B index, annual mean, annual minimum and maximum stream discharge across different model resolutions within each watershed category. The slope for 10x10 and 30x30m spatial resolution for annual mean, and minimum streamflow were not significantly different from zero across all watershed sizes indicating lack of interaction. However, slope for the R-B flashiness was significantly different from zero for the 90x90 m grid size indicating that watershed size change is sensitive at this spatial resolution. The variability of R-B index, annual mean and annual minimum hydrologic metrics decreased with increasing watershed size but

  18. High spatial resolution brain functional MRI using submillimeter balanced steady-state free precession acquisition

    SciTech Connect

    Wu, Pei-Hsin; Chung, Hsiao-Wen; Tsai, Ping-Huei; Wu, Ming-Long; Chuang, Tzu-Chao; Shih, Yi-Yu; Huang, Teng-Yi

    2013-12-15

    Purpose: One of the technical advantages of functional magnetic resonance imaging (fMRI) is its precise localization of changes from neuronal activities. While current practice of fMRI acquisition at voxel size around 3 × 3 × 3 mm{sup 3} achieves satisfactory results in studies of basic brain functions, higher spatial resolution is required in order to resolve finer cortical structures. This study investigated spatial resolution effects on brain fMRI experiments using balanced steady-state free precession (bSSFP) imaging with 0.37 mm{sup 3} voxel volume at 3.0 T. Methods: In fMRI experiments, full and unilateral visual field 5 Hz flashing checkerboard stimulations were given to healthy subjects. The bSSFP imaging experiments were performed at three different frequency offsets to widen the coverage, with functional activations in the primary visual cortex analyzed using the general linear model. Variations of the spatial resolution were achieved by removing outerk-space data components. Results: Results show that a reduction in voxel volume from 3.44 × 3.44 × 2 mm{sup 3} to 0.43 × 0.43 × 2 mm{sup 3} has resulted in an increase of the functional activation signals from (7.7 ± 1.7)% to (20.9 ± 2.0)% at 3.0 T, despite of the threefold SNR decreases in the original images, leading to nearly invariant functional contrast-to-noise ratios (fCNR) even at high spatial resolution. Activation signals aligning nicely with gray matter sulci at high spatial resolution would, on the other hand, have possibly been mistaken as noise at low spatial resolution. Conclusions: It is concluded that the bSSFP sequence is a plausible technique for fMRI investigations at submillimeter voxel widths without compromising fCNR. The reduction of partial volume averaging with nonactivated brain tissues to retain fCNR is uniquely suitable for high spatial resolution applications such as the resolving of columnar organization in the brain.

  19. Spatial and frequency-based super-resolution of ultrasound images.

    PubMed

    Wu, Mon-Ju; Karls, Joseph; Duenwald-Kuehl, Sarah; Vanderby, Ray; Sethares, William

    2014-07-01

    Modern ultrasound systems can output video images containing more spatial and temporal information than still images. Super-resolution techniques can exploit additional information but face two challenges: image registration and complex motion. In addition, information from multiple available frequencies is unexploited. Herein, we utilised these information sources to create better ultrasound images and videos, extending existing technologies for image capture. Spatial and frequency-based super-resolution processing using multiple motion estimation and frequency combination was applied to ultrasound videos of deforming models. Processed images are larger, have greater clarity and detail, and less variability in intensity between frames. Significantly, strain measurements are more accurate and precise than those from raw videos, and have a higher contrast ratio between 'tumour' and 'surrounding tissue' in a phantom model. We attribute improvements to reduced noise and increased resolution in processed images. Our methods can significantly improve quantitative and qualitative assessments of ultrasound images when compared assessments of standard images.

  20. Linear mixing model applied to coarse spatial resolution data from multispectral satellite sensors

    NASA Technical Reports Server (NTRS)

    Holben, Brent N.; Shimabukuro, Yosio E.

    1993-01-01

    A linear mixing model was applied to coarse spatial resolution data from the NOAA Advanced Very High Resolution Radiometer. The reflective component of the 3.55-3.95 micron channel was used with the two reflective channels 0.58-0.68 micron and 0.725-1.1 micron to run a constrained least squares model to generate fraction images for an area in the west central region of Brazil. The fraction images were compared with an unsupervised classification derived from Landsat TM data acquired on the same day. The relationship between the fraction images and normalized difference vegetation index images show the potential of the unmixing techniques when using coarse spatial resolution data for global studies.

  1. Time-Resolved High-Spatial-Resolution Measurements of Underwater Laser Ionization and Filamentation

    NASA Astrophysics Data System (ADS)

    Jones, T. G.; Kaganovich, D.; Helle, M. H.; Penano, J.; Ting, A.; Gordon, D.

    2013-10-01

    Laser triggering and guiding of underwater electrical discharges are being investigated and developed at NRL for applications including advanced micromachining and low-frequency laser acoustic generation. As part of this development we recently made several high-spatial-resolution, time-resolved measurements of underwater optical filamentation and laser ionization. Using 2-laser pump-probe backlit imaging techniques, we were able to achieve time resolution as short as 35 fs and spatial resolution down to 1 micron. Shadowgraph images show few-micron diameter gas bubbles forming throughout the pump beam path in ps timescales. Microbubble numbers and density increased with pulse energy and time during the pump pulse. We also obtained time-resolved spectra of ns-laser-ionized water, revealing black-body radiation lasting more than 100 ns after the ionizing pulse. Results from ongoing underwater laser ionization, filamentation, and discharge-guiding experiments will be presented. This work is supported by NRL Base Funds.

  2. Evidencing the need for high spatial resolution in angle-resolved photoemission experiments

    NASA Astrophysics Data System (ADS)

    Joucken, Frédéric; Reckinger, Nicolas; Lorcy, Stéphane; Avila, José; Chen, Chaoyu; Lagoute, Jérôme; Colomer, Jean-François; Ghijsen, Jacques; Asensio, Maria Carmen; Sporken, Robert

    2016-06-01

    Angle-resolved photoemission spectroscopy (ARPES) is the most direct tool to measure the electronic structure of materials. In particular, fine features of the spectra can be analyzed for evaluating the electron self-energy. Owing to a setup allowing ARPES investigation with submicron resolution and state-of-the-art energy and momentum resolution, we show here first that ARPES spectra of pristine and virtually undoped monolayer graphene acquired on a small spot do not display manifestations of self-energy. We next demonstrate that, although the region of the sample investigated is a unique graphene domain, it displays faint spatial inhomogeneity, both in its crystallographic orientation and its thickness, which is undetectable with conventional ARPES but renders the spectra improper for self-energy extraction. These results indicate that care should be taken when analyzing ARPES spectra obtained with poor spatial resolution.

  3. Measurement of residual stresses on ceramic materials with high spatial resolution

    SciTech Connect

    Kozaczek, K.J.; Ruud, C.O.; Fitting, J.D.

    1993-12-31

    A fast x-ray diffraction technique has been developed for measuring the residual stresses with high spatial resolution in ceramic materials. This resolution is limited by the mean size of grains and the radiation type. The effective diffraction elastic constants were experimentally determined for alumina as (E/l+{nu})){sub (1016)} = 200 GPa. The accuracy of XRD measurement of residual stresses with the spatial resolution of 170 {mu}m and precision {plus_minus} 15 MPa was verified experimentally by strain gauge measurements. The stress field around a singular Kovar pin brazed to alumina was asymmetric with high tangential stresses in the vicinity of the pin decreasing with the distance from the pin.

  4. Spatial Resolution Characterization for QuickBird Image Products 2003-2004 Season

    NASA Technical Reports Server (NTRS)

    Blonski, Slawomir

    2006-01-01

    This presentation focuses on spatial resolution characterization for QuickBird panochromatic images in 2003-2004 and presents data measurements and analysis of SSC edge target deployment and edge response extraction and modeling. The results of the characterization are shown as values of the Modulation Transfer Function (MTF) at the Nyquist spatial frequency and as the Relative Edge Response (RER) components. The results show that RER is much less sensitive to accuracy of the curve fitting than the value of MTF at Nyquist frequency. Therefore, the RER/edge response slope is a more robust estimator of the digital image spatial resolution than the MTF. For the QuickBird panochromatic images, the RER is consistently equal to 0.5 for images processed with the Cubic Convolution resampling and to 0.8 for the MTF resampling.

  5. Spatial resolution of SQUID magnetometers and comparison with low noise room temperature magnetic sensors

    NASA Astrophysics Data System (ADS)

    Dolabdjian, C.; Qasimi, A.; Bloyet, D.; Mosser, V.

    2002-03-01

    Any magnetic sensor placed in a spatially inhomogeneous magnetic field delivers a signal proportional the mean field value taken over an effective area or volume which depends on the type of sensor considered. In the case of the field produced by a magnetic dipole and detected by a square or circular planar sensor, the overall measured spatial resolution ideally depends on the ratio of the mean dipole-sensor distance z0 to the square root of the effective sensor area AE. For Z 0/ A E≪1 , the spatial resolution is limited by the size of the sensor, whereas for z 0/ A E≫1 the dipole-sensor distance is the predominant factor. To compare various low noise magnetic sensors operating either at low temperature or at room temperature, we have measured their sensitivities and spatial responses to the field produced by a magnetic moment having the form of a tiny circular current loop. The sensors could be moved in all directions with respect to the current loop. The transfer of each sensor to the magnetic dipole field was compared to their response in a homogeneous field so as to deduce their effective area and compare this area to that deduced from independent spatial resolution measurements. We report the experimental results given by four types of sensors namely a dc-SQUID, a Hall effect sensor, a giant magneto-resistive sensor and a flux-gate sensor and discuss them by mean of a “figure of merit” criterion combining their spatial resolution and their sensitivity.

  6. Evaluation of spatial resolution in image acquisition by optical flatbed scanners for radiochromic film dosimetry

    NASA Astrophysics Data System (ADS)

    Asero, G.; Greco, C.; Gueli, A. M.; Raffaele, L.; Spampinato, S.

    2016-03-01

    Introduction: Radiochromic films are two-dimensional dosimeters that do not require developing and give values of absorbed dose with accuracy and precision. Since this dosimeter colours directly after irradiation, it can be digitized with commercial optical flatbed scanners to obtain a calibration curve that links blackening of the film with dose. Although the film has an intrinsic high spatial resolution, the scanner determines the actual resolution of this dosimeter, in particular the "dot per inch" (dpi) parameter. The present study investigates the effective spatial resolution of a scanner used for Gafchromic® XR-QA2 film (designed for radiology Quality Assurance) analysis. Material and methods: The quantitative evaluation of the resolution was performed with the Modulation Transfer Function (MTF) method, comparing the nominal resolution with the experimental one. The analysis was performed with two procedures. First, the 1951 USAF resolution test chart, a tool that tests the performance of optical devices, was used. Secondly, a combined system of mammography X-ray tube, XR-QA2 film and a bar pattern object was used. In both cases the MTF method has been applied and the results were compared. Results: The USAF and the film images have been acquired with increasing dpi and a standard protocol for radiochromic analysis, to evaluate horizontal and vertical and resolution. The effective resolution corresponds to the value of the MTF at 50%. In both cases and for both procedures, it was verified that, starting from a dpi value, the effective resolution saturates. Conclusion: The study found that, for dosimetric applications, the dpi of the scanner have to be adjusted to a reasonable value because, if too high, it requires high scanning and computational time without providing additional information.

  7. Spatial resolution versus data acquisition efficiency in mapping an inhomogeneous system with species diffusion

    PubMed Central

    Chen, Fengxiang; Zhang, Yong; Gfroerer, T. H.; Finger, A. N.; Wanlass, M. W.

    2015-01-01

    Traditionally, spatially-resolved photoluminescence (PL) has been performed using a point-by-point scan mode with both excitation and detection occurring at the same spatial location. But with the availability of high quality detector arrays like CCDs, an imaging mode has become popular for performing spatially-resolved PL. By illuminating the entire area of interest and collecting the data simultaneously from all spatial locations, the measurement efficiency can be greatly improved. However, this new approach has proceeded under the implicit assumption of comparable spatial resolution. We show here that when carrier diffusion is present, the spatial resolution can actually differ substantially between the two modes, with the less efficient scan mode being far superior. We apply both techniques in investigation of defects in a GaAs epilayer – where isolated singlet and doublet dislocations can be identified. A superposition principle is developed for solving the diffusion equation to extract the intrinsic carrier diffusion length, which can be applied to a system with arbitrarily distributed defects. The understanding derived from this work is significant for a broad range of problems in physics and beyond (for instance biology) – whenever the dynamics of generation, diffusion, and annihilation of species can be probed with either measurement mode. PMID:26035409

  8. Spatial Resolution Versus Data Acquisition Efficiency in Mapping an Inhomogeneous System with Species Diffusion

    SciTech Connect

    Chen, Fengxiang; Zhang, Yong; Gfroerer, T. H.; Finger, A. N.; Mark W. Wanlass

    2015-06-02

    Traditionally, spatially-resolved photoluminescence (PL) has been performed using a point-by-point scan mode with both excitation and detection occurring at the same spatial location. But with the availability of high quality detector arrays like CCDs, an imaging mode has become popular for performing spatially-resolved PL. By illuminating the entire area of interest and collecting the data simultaneously from all spatial locations, the measurement efficiency can be greatly improved. However, this new approach has proceeded under the implicit assumption of comparable spatial resolution. We show here that when carrier diffusion is present, the spatial resolution can actually differ substantially between the two modes, with the less efficient scan mode being far superior. We apply both techniques in investigation of defects in a GaAs epilayer – where isolated singlet and doublet dislocations can be identified. A superposition principle is developed for solving the diffusion equation to extract the intrinsic carrier diffusion length, which can be applied to a system with arbitrarily distributed defects. The understanding derived from this work is significant for a broad range of problems in physics and beyond (for instance biology) – whenever the dynamics of generation, diffusion, and annihilation of species can be probed with either measurement mode.

  9. Spatial Resolution Versus Data Acquisition Efficiency in Mapping an Inhomogeneous System with Species Diffusion

    DOE PAGES

    Chen, Fengxiang; Zhang, Yong; Gfroerer, T. H.; Finger, A. N.; Mark W. Wanlass

    2015-06-02

    Traditionally, spatially-resolved photoluminescence (PL) has been performed using a point-by-point scan mode with both excitation and detection occurring at the same spatial location. But with the availability of high quality detector arrays like CCDs, an imaging mode has become popular for performing spatially-resolved PL. By illuminating the entire area of interest and collecting the data simultaneously from all spatial locations, the measurement efficiency can be greatly improved. However, this new approach has proceeded under the implicit assumption of comparable spatial resolution. We show here that when carrier diffusion is present, the spatial resolution can actually differ substantially between the twomore » modes, with the less efficient scan mode being far superior. We apply both techniques in investigation of defects in a GaAs epilayer – where isolated singlet and doublet dislocations can be identified. A superposition principle is developed for solving the diffusion equation to extract the intrinsic carrier diffusion length, which can be applied to a system with arbitrarily distributed defects. The understanding derived from this work is significant for a broad range of problems in physics and beyond (for instance biology) – whenever the dynamics of generation, diffusion, and annihilation of species can be probed with either measurement mode.« less

  10. Spatial resolution requirements for traffic-related air pollutant exposure evaluations

    NASA Astrophysics Data System (ADS)

    Batterman, Stuart; Chambliss, Sarah; Isakov, Vlad

    2014-09-01

    Vehicle emissions represent one of the most important air pollution sources in most urban areas, and elevated concentrations of pollutants found near major roads have been associated with many adverse health impacts. To understand these impacts, exposure estimates should reflect the spatial and temporal patterns observed for traffic-related air pollutants. This paper evaluates the spatial resolution and zonal systems required to estimate accurately intraurban and near-road exposures of traffic-related air pollutants. The analyses use the detailed information assembled for a large (800 km2) area centered on Detroit, Michigan, USA. Concentrations of nitrogen oxides (NOx) due to vehicle emissions were estimated using hourly traffic volumes and speeds on 9700 links representing all but minor roads in the city, the MOVES2010 emission model, the RLINE dispersion model, local meteorological data, a temporal resolution of 1 h, and spatial resolution as low as 10 m. Model estimates were joined with the corresponding shape files to estimate residential exposures for 700,000 individuals at property parcel, census block, census tract, and ZIP code levels. We evaluate joining methods, the spatial resolution needed to meet specific error criteria, and the extent of exposure misclassification. To portray traffic-related air pollutant exposure, raster or inverse distance-weighted interpolations are superior to nearest neighbor approaches, and interpolations between receptors and points of interest should not exceed about 40 m near major roads, and 100 m at larger distances. For census tracts and ZIP codes, average exposures are overestimated since few individuals live very near major roads, the range of concentrations is compressed, most exposures are misclassified, and high concentrations near roads are entirely omitted. While smaller zones improve performance considerably, even block-level data can misclassify many individuals. To estimate exposures and impacts of traffic

  11. Spatial Resolution Requirements for Traffic-Related Air Pollutant Exposure Evaluations.

    PubMed

    Batterman, Stuart; Chambliss, Sarah; Isakov, Vlad

    2014-09-01

    Vehicle emissions represent one of the most important air pollution sources in most urban areas, and elevated concentrations of pollutants found near major roads have been associated with many adverse health impacts. To understand these impacts, exposure estimates should reflect the spatial and temporal patterns observed for traffic-related air pollutants. This paper evaluates the spatial resolution and zonal systems required to estimate accurately intraurban and near-road exposures of traffic-related air pollutants. The analyses use the detailed information assembled for a large (800 km(2)) area centered on Detroit, Michigan, USA. Concentrations of nitrogen oxides (NOx) due to vehicle emissions were estimated using hourly traffic volumes and speeds on 9,700 links representing all but minor roads in the city, the MOVES2010 emission model, the RLINE dispersion model, local meteorological data, a temporal resolution of 1 hr, and spatial resolution as low as 10 m. Model estimates were joined with the corresponding shape files to estimate residential exposures for 700,000 individuals at property parcel, census block, census tract, and ZIP code levels. We evaluate joining methods, the spatial resolution needed to meet specific error criteria, and the extent of exposure misclassification. To portray traffic-related air pollutant exposure, raster or inverse distance-weighted interpolations are superior to nearest neighbor approaches, and interpolations between receptors and points of interest should not exceed about 40 m near major roads, and 100 m at larger distances. For census tracts and ZIP codes, average exposures are overestimated since few individuals live very near major roads, the range of concentrations is compressed, most exposures are misclassified, and high concentrations near roads are entirely omitted. While smaller zones improve performance considerably, even block-level data can misclassify many individuals. To estimate exposures and impacts of traffic

  12. Scanning fiber endoscopy with highly flexible, 1-mm catheterscopes for wide-field, full-color imaging

    PubMed Central

    Lee, Cameron M.; Engelbrecht, Christoph J.; Soper, Timothy D.; Helmchen, Fritjof; Seibel, Eric J.

    2011-01-01

    In modern endoscopy, wide field of view and full color are considered necessary for navigating inside the body, inspecting tissue for disease and guiding interventions such as biopsy or surgery. Current flexible endoscope technologies suffer from reduced resolution when device diameter shrinks. Endoscopic procedures today using coherent fiber bundle technology, on the scale of 1 mm, are performed with such poor image quality that the clinician’s vision meets the criteria for legal blindness. Here, we review a new and versatile scanning fiber imaging technology and describe its implementation for ultrathin and flexible endoscopy. This scanning fiber endoscope (SFE) or catheterscope enables high quality, laser-based, video imaging for ultrathin clinical applications while also providing new options for in vivo biological research of subsurface tissue and high resolution fluorescence imaging. PMID:20336702

  13. Investigation of LANDSAT follow-on thematic mapper spatial, radiometric and spectral resolution

    NASA Technical Reports Server (NTRS)

    Nalepka, R. F. (Principal Investigator); Morgenstern, J. P.; Kent, E. R.; Erickson, J. D.

    1976-01-01

    The author has identified the following significant results. Fine resolution M7 multispectral scanner data collected during the Corn Blight Watch Experiment in 1971 served as the basis for this study. Different locations and times of year were studied. Definite improvement using 30-40 meter spatial resolution over present LANDSAT 1 resolution and over 50-60 meter resolution was observed, using crop area mensuration as the measure. Simulation studies carried out to extrapolate the empirical results to a range of field size distributions confirmed this effect, showing the improvement to be most pronounced for field sizes of 1-4 hectares. Radiometric sensitivity study showed significant degradation of crop classification accuracy immediately upon relaxation from the nominally specified values of 0.5% noise equivalent reflectance. This was especially the case for data which were spectrally similar such as that collected early in the growing season and also when attempting to accomplish crop stress detection.

  14. High-spatial-resolution microwave and related observations as diagnostics of coronal loops

    NASA Technical Reports Server (NTRS)

    Holman, Gordon D.

    1986-01-01

    High spatial resolution microwave observations of coronal loops, together with theoretical models for the loop emission, can provide detailed information about the temperature, density, and magnetic field within the loop, as well as the environment around the loop. The capability for studying magnetic fields is particularly important, since there is no comparable method for obtaining direct information about coronal magnetic fields. Knowledge of the magnetic field strength and structure in coronal loops is important for understanding both coronal heating and flares. With arc-second-resolution microwave observations from the Very Large Array (VLA), supplemental high-spectral-resolution microwave data from a facility such as the Owens Valley frequency-agile interferometer, and the ability to obtain second-of-arc resolution EUV aor soft X ray images, the capability already exists for obtaining much more detailed information about coronal plasma and magnetic structures than is presently available. This capability is discussed.

  15. Super-resolution imaging in digital holography by using dynamic grating with a spatial light modulator

    NASA Astrophysics Data System (ADS)

    Lin, Qiaowen; Wang, Dayong; Wang, Yunxin; Rong, Lu; Chang, Shifeng

    2015-03-01

    A super-resolution imaging method using dynamic grating based on liquid-crystal spatial light modulator (SLM) is developed to improve the resolution of a digital holographic system. The one-dimensional amplitude cosine grating is loaded on the SLM, which is placed between the object and hologram plane in order to collect more high-frequency components towards CCD plane. The point spread function of the system is given to confirm the separation condition of reconstructed images for multiple diffraction orders. The simulation and experiments are carried out for a standard resolution test target as a sample, which confirms that the imaging resolution is improved from 55.7 μm to 31.3 μm compared with traditional lensless Fourier transform digital holography. The unique advantage of the proposed method is that the period of the grating can be programmably adjusted according to the separation condition.

  16. Optical magnetometry with sub-wavelength spatial resolution using individual spins in diamond

    NASA Astrophysics Data System (ADS)

    Maze, Jeronimo; Maurer, Peter; Stanwix, Paul; Jiang, Liang; Hodges, Jonathan; Gorshkov, Alexey; Zibrov, Alexander; Walsworth, Ronald; Lukin, Mikhail

    2009-05-01

    The ability to map weak magnetic fields with nanometer resolution is of great importance in biological science and high precision metrology of nanoscale structures. We describe and demonstrate a new technique that combines high spatial resolution in the spirit of stimulating-emission-depletion (STED) fluorescence microscopy [1] and nanoscale magnetic sensing with individual spins in diamond [2,3]. This new magnetic sensing and nanometer resolution fluorescence microscopy approach (m-STED) will allow detection of single electronic spins at a distance of 10 nm with 5-7 folds improvement beyond the diffraction limit lateral resolution. [4pt] [1] Hell, S. W. and J. Wichmann, Opt. Lett. 19, 780 (1994).[2] J.R. Maze, et al., Nature 455, 644 (2008).[3] J.M. Taylor, et al., Nature Physics 4, 810 (2008).

  17. The method of improving the spatial resolution of the matrix spectrometer

    NASA Astrophysics Data System (ADS)

    Krot, Yury; Beliaev, Boris; Katkovsky, Leonid

    2014-10-01

    The videospectral system (VSS) intended for ecological space experiment on board of the International Space Station (ISS) has been developed by the Aerospace Researches Department of the Institute of Applied Physical Problems of the Belarusian State University. The system comprises three matrix spectrometers MP-15. The polychromator of each spectrometer includes the imaging fiber, the entrance slit, concave holographic diffraction grating, and a CCD array detector. The array photodetector measures the spectral radiation distribution in rows, and the spatial distribution (image) in columns. Astigmatism is a typical aberration of polychromators based on concave spherical gratings - rays in tangential and sagittal planes are focused at different points. This degrades as for spectral and spatial resolution along the entrance slit. The proposed method of obtaining high spatial resolution without spectral resolution loss consists in the displacement of the output end of the imaging fiber along the optical axis at a specified distance from the entrance slit. After that the rays in the tangential and sagittal planes focus at one point. The entrance slit operates as a one-dimensional aperture to obtain high spectral resolution.

  18. Spatial resolution effect on the simulated results of watershed scale models

    NASA Astrophysics Data System (ADS)

    Epelde, Ane; Antiguedad, Iñaki; Brito, David; Jauch, Eduardo; Neves, Ramiro; Sauvage, Sabine; Sánchez-Pérez, José Miguel

    2016-04-01

    Numerical models are useful tools for water resources planning, development and management. Currently, their use is being spread and more complex modeling systems are being employed for these purposes. The adding of complexity allows the simulation of water quality related processes. Nevertheless, this implies a considerable increase on the computational requirements, which usually is compensated on the models by a decrease on their spatial resolution. The spatial resolution of the models is known to affect the simulation of hydrological processes and therefore, also the nutrient exportation and cycling processes. However, the implication of the spatial resolution on the simulated results is rarely assessed. In this study, we examine the effect of the change in the grid size on the integrated and distributed results of the Alegria River watershed model (Basque Country, Northern Spain). Variables such as discharge, water table level, relative water content of soils, nitrogen exportation and denitrification are analyzed in order to quantify the uncertainty involved in the spatial discretization of the watershed scale models. This is an aspect that needs to be carefully considered when numerical models are employed in watershed management studies or quality programs.

  19. The criteria for measuring average density by x-ray attenuation: The role of spatial resolution

    SciTech Connect

    Friedman, W.

    1999-07-29

    It is well known that the attenuation of X-rays as they pass through a material can be used to quantify the amount of matter in their path. This is the basis for the gamma ray densitometer which can measure the amount of material on a moving conveyor belt. It is also the rationale for using X-rays for medical imaging as the attenuation can discriminate between tissue of different density and composition, yielding images of great diagnostic utility. Spatial resolution is obviously important with regard to detecting small features. However, it is less obvious that it plays an important role in obtaining quantitative information from the X-ray transmission data since the spatial resolution of the instrument can affect the accuracy of those measurements. This problem is particularly severe in the case of computed tomography where the accuracy of the reconstruction is dependent on the accuracy of the initial projection data. It should be noted that spatial resolution is not a concern for the case where the material is uniform. Here uniform is defined by small variations related to either the scale size of the resolution element in the detector, or to the size of a collimated X-ray beam. However, if the material has non-homogeneous composition or changes in density on the scale size of the systems spatial resolution, then there can be effects that will compromise the transmission data before it is acquired and these errors can not be corrected by any subsequent data processing. A method is presented for computing the density measurement error which parameterizes the effect in terms of the actual modulation on the face of the detector and the attenuation in the material. For cases like stacks of lead plates the errors can exceed 80%.

  20. The effects of spatial resolution on integral field spectrograph surveys at different redshifts - The CALIFA perspective

    NASA Astrophysics Data System (ADS)

    Mast, D.; Rosales-Ortega, F. F.; Sánchez, S. F.; Vílchez, J. M.; Iglesias-Paramo, J.; Walcher, C. J.; Husemann, B.; Márquez, I.; Marino, R. A.; Kennicutt, R. C.; Monreal-Ibero, A.; Galbany, L.; de Lorenzo-Cáceres, A.; Mendez-Abreu, J.; Kehrig, C.; del Olmo, A.; Relaño, M.; Wisotzki, L.; Mármol-Queraltó, E.; Bekeraitè, S.; Papaderos, P.; Wild, V.; Aguerri, J. A. L.; Falcón-Barroso, J.; Bomans, D. J.; Ziegler, B.; García-Lorenzo, B.; Bland-Hawthorn, J.; López-Sánchez, Á. R.; van de Ven, G.

    2014-01-01

    Context. Over the past decade, 3D optical spectroscopy has become the preferred tool for understanding the properties of galaxies and is now increasingly used to carry out galaxy surveys. Low redshift surveys include SAURON, DiskMass, ATLAS3D, PINGS, and VENGA. At redshifts above 0.7, surveys such as MASSIV, SINS, GLACE, and IMAGES have targeted the most luminous galaxies to study mainly their kinematic properties. The on-going CALIFA survey (z ~ 0.02) is the first of a series of upcoming integral field spectroscopy (IFS) surveys with large samples representative of the entire population of galaxies. Others include SAMI and MaNGA at lower redshift and the upcoming KMOS surveys at higher redshift. Given the importance of spatial scales in IFS surveys, the study of the effects of spatial resolution on the recovered parameters becomes important. Aims: We explore the capability of the CALIFA survey and a hypothetical higher redshift survey to reproduce the properties of a sample of objects observed with better spatial resolution at lower redshift. Methods: Using a sample of PINGS galaxies, we simulated observations at different redshifts. We then studied the behaviour of different parameters as the spatial resolution degrades with increasing redshift. Results: We show that at the CALIFA resolution, we are able to measure and map common observables in a galaxy study: the number and distribution of H ii regions (Hα flux structure), the gas metallicity (using the O3N2 method), the gas ionization properties (through the [N ii]/Hα and [O iii]/Hβ line ratios), and the age of the underlying stellar population (using the D4000 index). This supports the aim of the survey to characterise the observable properties of galaxies in the Local Universe. Our analysis of simulated IFS data cubes at higher redshifts highlights the importance of the projected spatial scale per spaxel as the most important figure of merit in the design of an integral field survey.

  1. Additional atmospheric opacity measurements at lambda = 1.1 mm from Mauna Kea Observatory, Hawaii

    NASA Technical Reports Server (NTRS)

    Parrish, A.; De Zafra, R. L.; Barrett, J. W.; Solomon, P.; Connor, B.

    1987-01-01

    Atmospheric opacity values in the zenith direction are given for a wavelength of 1.1 mm (278 GHz) at the summit of Mauna Kea in the Hawaiian Islands. A total of 75 days is covered during the period 1983-1986. Observations were made on a quasi-continuous basis, with opacity measured every 20 minutes around the clock for significant periods of time. A conversion from opacity at lambda = 1.1 mm to the equivalent precipitable water vapor column is given from the measurements of Zammit and Ade (1981), from which opacities at other wavelengths may be derived.

  2. High spatial resolution remote sensing imagery improves GPP predictions in disturbed, semi-arid woodlands

    NASA Astrophysics Data System (ADS)

    Krofcheck, D. J.; Eitel, J.; Vierling, L. A.; Schulthess, U.; Litvak, M. E.

    2012-12-01

    Climate across the globe is changing and consequently the productivity of terrestrial vegetation is changing with it. Gross primary productivity (GPP) is an integral part of the carbon cycle, yet challenging to measure everywhere, all the time. Efforts to estimate GPP in the context of climate change are becoming continually more salient of the need for models sensitive to the heterogeneous nature of drought and pest induced disturbance. Given the increased availability of high spatial resolution remotely sensed imagery, their use in ecosystem scale GPP estimation is becoming increasingly viable. We used a simple linear model with inputs derived from RapidEye time series data (5 meter spatial resolution) as compared to MODIS inputs (250 meter spatial resolution) to estimate GPP in intact and girdled PJ woodland to simulate drought and pest induced disturbance. An area equal to the MODIS pixels measured was aggregated using RapidEye data centered on the flux towers for comparison purposes. We generated four model runs, two using only MODIS or RapidEye spectral vegetation indices (VIs) and two using MODIS and RapidEye VIs combined at both the control and disturbed tower site. Our results suggest that for undisturbed regions, MODIS derived VIs perform better than the higher spatial resolution RapidEye VIs when a moisture sensitive index is incorporated into the model (RMSE of 17.51for MODIS vs. 22.71 for RapidEye). Modeling GPP in disturbed regions however benefits from the inclusion of high spatial resolution data (RMSE of 14.83 for MODIS vs. 14.70 for RapidEye). This discrepancy may have to do with the disparate scale of a MODIS pixel and the size of the tower fetch. Our results suggest that the best source of VI's for the modeling GPP in semi-arid woodlands depends on the level of disturbance in the landscape. Given that the rate and extent of drought and insect induced mortality events in terrestrial forests are projected to increase with our changing climate

  3. High spatial resolution upgrade of the electron cyclotron emission radiometer for the DIII-D tokamak

    SciTech Connect

    Truong, D. D.; Austin, M. E.

    2014-11-15

    The 40-channel DIII-D electron cyclotron emission (ECE) radiometer provides measurements of T{sub e}(r,t) at the tokamak midplane from optically thick, second harmonic X-mode emission over a frequency range of 83–130 GHz. The frequency spacing of the radiometer's channels results in a spatial resolution of ∼1–3 cm, depending on local magnetic field and electron temperature. A new high resolution subsystem has been added to the DIII-D ECE radiometer to make sub-centimeter (0.6–0.8 cm) resolution T{sub e} measurements. The high resolution subsystem branches off from the regular channels’ IF bands and consists of a microwave switch to toggle between IF bands, a switched filter bank for frequency selectivity, an adjustable local oscillator and mixer for further frequency down-conversion, and a set of eight microwave filters in the 2–4 GHz range. Higher spatial resolution is achieved through the use of a narrower (200 MHz) filter bandwidth and closer spacing between the filters’ center frequencies (250 MHz). This configuration allows for full coverage of the 83–130 GHz frequency range in 2 GHz bands. Depending on the local magnetic field, this translates into a “zoomed-in” analysis of a ∼2–4 cm radial region. Expected uses of these channels include mapping the spatial dependence of Alfven eigenmodes, geodesic acoustic modes, and externally applied magnetic perturbations. Initial T{sub e} measurements, which demonstrate that the desired resolution is achieved, are presented.

  4. Impact of spatial input data resolution on hydrological and erosion modeling: Recommendations from a global assessment

    NASA Astrophysics Data System (ADS)

    Chaplot, V.

    The need to precisely describe the characteristics of a landscape is well-known in mathematical modeling from different environmental disciplines. Because spatial input data, such as climate, relief and soil maps are costly to obtain, especially when large areas are considered, several research studies have investigated the extent to which the resolution of these can be reduced. Yet, a consensus has not been reached on the question of models' sensitivity to the whole range of spatial input data and for different environmental conditions. This issue was illustrated with the analysis of existing results from 41 watersheds from 30 research studies using the Soil and Water Assessment Tool (SWAT). Because these studies were not consistent in the type of spatial input data considered and the range of resolutions, an application of SWAT was performed in a flat 2612 ha flat watershed of central Iowa (USA) where the sensitivity of runoff (R), NO3-N (N) and sediment (SED) yields was tested for changes in the resolution of all the required spatial input data (digital elevation model: DEM: 20-500 m; n = 12; number of rain gauge: NRAIN from 1 to 13; n = 8; soil map: SOIL: 1/25,000-1/500,000; n = 3) and in the number of watershed sub-divisions (NSW from 4 to 115; n = 4). At the flat watershed, a Canonical Correlation Analysis with 67.4% of data variance explained by the two first variates, revealed that R and SED predictions were affected, mostly by NSW (r = 0.95), followed by SOIL (r = 0.18). N loads were the most sensitive to RAIN (r = 0.76) and DEM (r = 0.41), followed by SOIL (r = 0.23) and NSW (r = -0.17). The Kolmogorov-Smirnov statistic (KS), that describes the significance of resolution changes for a considered spatial input data, showed that the model's sensitivity was greater for SSW below 261 ha, for 30 < DEM < 100 m and across the whole range of NRAIN. Finally, the analysis of watersheds with different sizes and environmental conditions revealed that the minimum

  5. Investigation of the Intrinsic Spatial Resolution of an Intensified EMCCD Scintillation Camera

    PubMed Central

    Meng, L. J.; Fu, G.

    2016-01-01

    In this paper, we present an experimental and Monte Carlo investigation of the intrinsic spatial resolution that can be achieved with the intensified electron-multiplying charge-coupled device (I-EMCCD) gamma camera [1]–[4]. This detector has a very low readout noise, an ultra-high spatial resolution and a large active area of ~ 80 mm diameter, which is well-suited for small animal imaging applications. The intrinsic detector resolutions achieved with different scintillators and under different experimental conditions were compared. In this study, the simple centroiding method was compared with two model-fitting approaches for finding the locations of gamma ray interactions. The results from Monte Carlo simulation have demonstrated that with an appropriate detector configuration, it is possible to achieve an intrinsic resolution of ~ 30 µm FWHM for detecting 27–35 keV gamma rays. The I-EMCCD scintillation camera offers a promising candidate for future ultra-high resolution SPECT imaging applications.

  6. Spatial resolution recovery utilizing multi-ray tracing and graphic processing unit in PET image reconstruction.

    PubMed

    Liang, Yicheng; Peng, Hao

    2015-02-01

    Depth-of-interaction (DOI) poses a major challenge for a PET system to achieve uniform spatial resolution across the field-of-view, particularly for small animal and organ-dedicated PET systems. In this work, we implemented an analytical method to model system matrix for resolution recovery, which was then incorporated in PET image reconstruction on a graphical processing unit platform, due to its parallel processing capacity. The method utilizes the concepts of virtual DOI layers and multi-ray tracing to calculate the coincidence detection response function for a given line-of-response. The accuracy of the proposed method was validated for a small-bore PET insert to be used for simultaneous PET/MR breast imaging. In addition, the performance comparisons were studied among the following three cases: 1) no physical DOI and no resolution modeling; 2) two physical DOI layers and no resolution modeling; and 3) no physical DOI design but with a different number of virtual DOI layers. The image quality was quantitatively evaluated in terms of spatial resolution (full-width-half-maximum and position offset), contrast recovery coefficient and noise. The results indicate that the proposed method has the potential to be used as an alternative to other physical DOI designs and achieve comparable imaging performances, while reducing detector/system design cost and complexity.

  7. [A novel spatial modulation Fourier transform spectrometer with adjustable spectral resolution].

    PubMed

    Lian, Yu-Sheng; Liao, Ning-Fang; Lü, Hang; Wu, Wen-Min; Dong, Zhi-Gang

    2014-11-01

    In the premise of fulfilling the application requirement, the adjustment of spectral resolution can improve efficiency of data acquisition, data processing and data saving. So, by adjusting the spectral resolution, the performance of spectrometer can be improved, and its application range can be extended. To avoid the problems of the fixed spectral resolution of classical Fourier transform spectrometer, a novel type of spatial modulation Fourier transform spectrometer with adjustable spectral resolution is proposed in this paper. The principle of the novel spectrometer and its interferometer is described. The general expressions of the optical path difference and the lateral shear are induced by a ray tracing procedure. The equivalent model of the novel interferometer is analyzed. Meanwhile, the principle of the adjustment of spectral resolution is analyzed. The result shows that the novel spectrometer has the merits of adjustable spectral resolution, high stability, easy assemblage and adjustment etc. This theoretical study will provide the theoretical basis for the design of the spectrometer with adjustable spectral resolution and expand the application range of Fourier transform spectrometer.

  8. Tomographic retrieval for scattered light limb measurements: multiple spectral fit windows to improve the spatial resolution

    NASA Astrophysics Data System (ADS)

    Pukite, Janis; Dörner, Steffen; Wagner, Thomas

    2015-04-01

    The Scanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) on the ENVISAT satellite probed the atmosphere at the day side of Earth in alternating sequences of nadir and limb measurements from August 2002 to April 2012. Limb measurements allow the retrieval of stratospheric profiles of various trace gases on a global scale. It has been shown that combining measurements of the same air volume from different viewing positions along the orbit, 2D distribution fields of stratospheric trace gases can be acquired in one inversion step. Since the atmospheric scattering and absorption processes are wavelength dependent, the spatial sensitivity for limb observations also varies with wavelength. In general, for longer wavelengths, photons from more remote areas along the line of sight are contributing stronger to the measurement than for shorter wavelengths because of the lower probability of Rayleigh scattering. In addition, the radiative transfer is modified by the ozone absorption structures making longer light paths less probable within strong ozone absorption bands. In this study, additional information on the spatial distribution of NO2 is investigated by analysing results obtained by Differential Optical Absorption Spectroscopy (DOAS) in various spectral fit windows. Combing the fit results in one profile retrieval algorithm helps to improve the spatial sensitivity and resolution of the measurements. The largest improvements for the spatial resolution and sensitivity are expected for the upper troposphere/ lower stratosphere (UTLS) region where the variation of the spatial sensitivity with wavelength is strongest.

  9. High cognitive reserve is associated with a reduced age-related deficit in spatial conflict resolution

    PubMed Central

    Puccioni, Olga; Vallesi, Antonino

    2012-01-01

    Several studies support the existence of a specific age-related difficulty in suppressing potentially distracting information. The aim of the present study is to investigate whether spatial conflict resolution is selectively affected by aging. The way aging affects individuals could be modulated by many factors determined by the socieconomic status: we investigated whether factors such as cognitive reserve (CR) and years of education may play a compensatory role against age-related deficits in the spatial domain. A spatial Stroop task with no feature repetitions was administered to a sample of 17 non-demented older adults (69–79 years-old) and 18 younger controls (18–34 years-old) matched for gender and years of education. The two age groups were also administered with measures of intelligence and CR. The overall spatial Stroop effect did not differ according to age, neither for speed nor for accuracy. The two age groups equally showed sequential effects for congruent trials: reduced response times (RTs) if another congruent trial preceded them, and accuracy at ceiling. For incongruent trials, older adults, but not younger controls, were influenced by congruency of trialn−1, since RTs increased with preceding congruent trials. Interestingly, such an age-related modulation negatively correlated with CR. These findings suggest that spatial conflict resolution in aging is predominantly affected by general slowing, rather than by a more specific deficit. However, a high level of CR seems to play a compensatory role for both factors. PMID:23248595

  10. A versatile fluorescence lifetime imaging system for scanning large areas with high time and spatial resolution

    NASA Astrophysics Data System (ADS)

    Bernardo, César; Belsley, Michael; de Matos Gomes, Etelvina; Gonçalves, Hugo; Isakov, Dmitry; Liebold, Falk; Pereira, Eduardo; Pires, Vladimiro; Samantilleke, Anura; Vasilevskiy, Mikhail; Schellenberg, Peter

    2014-08-01

    We present a flexible fluorescence lifetime imaging device which can be employed to scan large sample areas with a spatial resolution adjustable from many micrometers down to sub-micrometers and a temporal resolution of 20 picoseconds. Several different applications of the system will be presented including protein microarrays analysis, the scanning of historical samples, evaluation of solar cell surfaces and nanocrystalline organic crystals embedded in electrospun polymeric nanofibers. Energy transfer processes within semiconductor quantum dot superstructures as well as between dye probes and graphene layers were also investigated.

  11. A new method for spatial resolution enhancement of hyperspectral images using sparse coding and linear spectral unmixing

    NASA Astrophysics Data System (ADS)

    Hashemi, Nezhad Z.; Karami, A.

    2015-10-01

    Hyperspectral images (HSI) have high spectral and low spatial resolutions. However, multispectral images (MSI) usually have low spectral and high spatial resolutions. In various applications HSI with high spectral and spatial resolutions are required. In this paper, a new method for spatial resolution enhancement of HSI using high resolution MSI based on sparse coding and linear spectral unmixing (SCLSU) is introduced. In the proposed method (SCLSU), high spectral resolution features of HSI and high spatial resolution features of MSI are fused. In this case, the sparse representation of some high resolution MSI and linear spectral unmixing (LSU) model of HSI and MSI is simultaneously used in order to construct high resolution HSI (HRHSI). The fusion process of HSI and MSI is formulated as an ill-posed inverse problem. It is solved by the Split Augmented Lagrangian Shrinkage Algorithm (SALSA) and an orthogonal matching pursuit (OMP) algorithm. Finally, the proposed algorithm is applied to the Hyperion and ALI datasets. Compared with the other state-of-the-art algorithms such as Coupled Nonnegative Matrix Factorization (CNMF) and local spectral unmixing, the SCLSU has significantly increased the spatial resolution and in addition the spectral content of HSI is well maintained.

  12. Spatial and Temporal Data Fusion for Generating High-Resolution Land Cover Imagery

    NASA Astrophysics Data System (ADS)

    Xu, Yong

    Currently, remote sensing imagery has been widely used for generating global land cover products, but due to certain physical and budget limitations related to the sensors, their spatial and temporal resolution are too low to attain more accurate and more reliable global change research. In this situation, there is an urgent need to study and develop a more advanced satellite image processing method and land cover producing techniques to generate higher resolution images and land cover products for global change research. Through conducting a comprehensive study of the related theories and methods related to data fusion, various methods are systematically reviewed and summarized, such as HIS transformation image fusion, Wavelet transform image fusion, the Spatial and Temporal Adaptive Reflectance Fusion Model (STARFM), etc. The advantages and disadvantages of these methods are highlighted according to their specific applications in the field of remote sensing. Based on my research target, the following are the main contents of this thesis: (1) Data fusion theory will be systematically studied and summarized, including various fusion models and specific applications, such as IHS transformation, PCA transformation, Wavelet analysis based data fusion, etc. Furthermore, their advantages and disadvantages are pointed out in relation to specific applications. (2) As traditional data fusion methods rely on spatial information and it is hard to deal with multi-source data fusion with temporal variation, therefore, the traditional data fusion theory and methods will be improved by a consideration of temporal information. Accordingly, some spatial and temporal data fusion methods will be proposed, in which both high-resolution & low-temporary imagery and low-resolution & high-temporary imagery are incorporated. Our experiments also show that they are suitable for dealing with multi-temporal data integration and generating high-resolution, multi-temporal images for global

  13. Atmospheric Moisture Budget and Spatial Resolution Dependence of Precipitation Extremes in Aquaplanet Simulations

    SciTech Connect

    Yang, Qing; Leung, Lai-Yung R.; Rauscher, Sara; Ringler, Todd; Taylor, Mark

    2014-05-01

    data aggregation effect in omega, thermodynamic changes become relatively significant in offsetting the effect of dynamics leading to reduce differences between the simulated and aggregated results. Compared to MPAS, the simulated stronger vertical motion with HOMME also results in larger resolution dependency. Compared to the simulation at fine resolution, the vertical motion during extremes is insufficiently resolved/parameterized at the coarser resolution even after accounting for the natural reduction in variability with coarser resolution, and this is more distinct in the simulation with HOMME. To reduce uncertainties in simulated precipitation extremes, future development in cloud parameterizations must address their sensitivity to spatial resolution as well as dynamical cores.

  14. 3D high spectral and spatial resolution imaging of ex vivo mouse brain

    SciTech Connect

    Foxley, Sean Karczmar, Gregory S.; Domowicz, Miriam; Schwartz, Nancy

    2015-03-15

    Purpose: Widely used MRI methods show brain morphology both in vivo and ex vivo at very high resolution. Many of these methods (e.g., T{sub 2}{sup *}-weighted imaging, phase-sensitive imaging, or susceptibility-weighted imaging) are sensitive to local magnetic susceptibility gradients produced by subtle variations in tissue composition. However, the spectral resolution of commonly used methods is limited to maintain reasonable run-time combined with very high spatial resolution. Here, the authors report on data acquisition at increased spectral resolution, with 3-dimensional high spectral and spatial resolution MRI, in order to analyze subtle variations in water proton resonance frequency and lineshape that reflect local anatomy. The resulting information compliments previous studies based on T{sub 2}{sup *} and resonance frequency. Methods: The proton free induction decay was sampled at high resolution and Fourier transformed to produce a high-resolution water spectrum for each image voxel in a 3D volume. Data were acquired using a multigradient echo pulse sequence (i.e., echo-planar spectroscopic imaging) with a spatial resolution of 50 × 50 × 70 μm{sup 3} and spectral resolution of 3.5 Hz. Data were analyzed in the spectral domain, and images were produced from the various Fourier components of the water resonance. This allowed precise measurement of local variations in water resonance frequency and lineshape, at the expense of significantly increased run time (16–24 h). Results: High contrast T{sub 2}{sup *}-weighted images were produced from the peak of the water resonance (peak height image), revealing a high degree of anatomical detail, specifically in the hippocampus and cerebellum. In images produced from Fourier components of the water resonance at −7.0 Hz from the peak, the contrast between deep white matter tracts and the surrounding tissue is the reverse of the contrast in water peak height images. This indicates the presence of a shoulder in

  15. Effects of spatial resolution of remotely sensed data on estimating urban impervious surfaces.

    PubMed

    Li, Weifeng; Ouyang, Zhiyun; Zhou, Weiqi; Chen, Qiuwen

    2011-01-01

    Impervious surfaces are the result of urbanization that can be explicitly quantified, managed and controlled at each stage of land development. It is a very useful environmental indicator that can be used to measure the impacts of urbanization on surface runoff, water quality, air quality, biodiversity and microclimate. Therefore, accurate estimation of impervious surfaces is critical for urban environmental monitoring, land management, decision-making and urban planning. Many approaches have been developed to estimate surface imperviousness, using remotely sensed data with various spatial resolutions. However, few studies, have investigated the effects of spatial resolution on estimating surface imperviousness. We compare medium-resolution Landsat data with high-resolution SPOT images to quantify the imperviousness in Beijing, China. The results indicated that the overall 91% accuracy of estimates of imperviousness based on TM data was considerably higher than the 81% accuracy of the SPOT data. The higher resolution SPOT data did not always predict the imperviousness of the land better than the TM data. At the whole city level, the TM data better predicts the percentage cover of impervious surfaces. At the sub-city level, however, the ring belts from the central core to the urban-rural peripheral, the SPOT data may better predict the imperviousness. These results highlighted the need to combine multiple resolution data to quantify the percentage of imperviousness, as higher resolution data do not necessarily lead to more accurate estimates. The methodology and results in this study can be utilized to identify the most suitable remote sensing data to quickly and efficiently extract the pattern of the impervious land, which could provide the base for further study on many related urban environmental problems.

  16. Hard X-ray Microscopy with sub 30 nm Spatial Resolution

    NASA Astrophysics Data System (ADS)

    Tang, Mau-Tsu; Song, Yen-Fang; Yin, Gung-Chian; Chen, Fu-Rong; Chen, Jian-Hua; Chen, Yi-Ming; Liang, Keng S.; Duewer, F.; Yun, Wenbing

    2007-01-01

    A transmission X-ray microscope (TXM) has been installed at the BL01B beamline at National Synchrotron Radiation Research Center in Taiwan. This state-of-the-art TXM operational in a range 8-11 keV provides 2D images and 3D tomography with spatial resolution 60 nm, and with the Zernike-phase contrast mode for imaging light materials such as biological specimens. A spatial resolution of the TXM better than 30 nm, apparently the best result in hard X-ray microscopy, has been achieved by employing the third diffraction order of the objective zone plate. The TXM has been applied in diverse research fields, including analysis of failure mechanisms in microelectronic devices, tomographic structures of naturally grown photonic specimens, and the internal structure of fault zone gouges from an earthquake core. Here we discuss the scope and prospects of the project, and the progress of the TXM in NSRRC.

  17. Hard X-ray Microscopy with sub 30 nm Spatial Resolution

    SciTech Connect

    Tang, M.-T.; Song, Y.-F.; Yin, G.-C.; Chen, J.-H.; Chen, Y.-M.; Liang, Keng S.; Chen, F.-R.; Duewer, F.; Yun Wenbing

    2007-01-19

    A transmission X-ray microscope (TXM) has been installed at the BL01B beamline at National Synchrotron Radiation Research Center in Taiwan. This state-of-the-art TXM operational in a range 8-11 keV provides 2D images and 3D tomography with spatial resolution 60 nm, and with the Zernike-phase contrast mode for imaging light materials such as biological specimens. A spatial resolution of the TXM better than 30 nm, apparently the best result in hard X-ray microscopy, has been achieved by employing the third diffraction order of the objective zone plate. The TXM has been applied in diverse research fields, including analysis of failure mechanisms in microelectronic devices, tomographic structures of naturally grown photonic specimens, and the internal structure of fault zone gouges from an earthquake core. Here we discuss the scope and prospects of the project, and the progress of the TXM in NSRRC.

  18. Experimental Estimation of CLASP Spatial and Spectral Resolutions: Results of the Instrument's Optical Alignment

    NASA Technical Reports Server (NTRS)

    Giono, G.; Katsukawa, Y.; Ishikawa, R.; Narukage, N.; Bando, T.; Kano, R.; Suematsu, Y.; Winebarger, A.; Kobayashi, K.; Auchere, F.

    2015-01-01

    The Chromospheric Lyman-Alpha SpectroPolarimeter is a sounding rocket experiment design to measure for the first time the polarization signal of the Lyman-Alpha line (121.6nm), emitted in the solar upper-chromosphere and transition region. This instrument aims to detect the Hanle effect's signature hidden in the Ly-alpha polarization, as a tool to probe the chromospheric magnetic field. Hence, an unprecedented polarization accuracy is needed ((is) less than 10 (exp -3). Nevertheless, spatial and spectral resolutions are also crucial to observe chhromospheric feature such as spicules, and to have precise measurement of the Ly-alpha line core and wings. Hence, this poster will present how the telescope and the spectrograph were separately aligned, and their combined spatial and spectral resolutions.

  19. High spatial resolution characterization of silicon solar cells using thermoreflectance imaging

    NASA Astrophysics Data System (ADS)

    Zhou, Qiaoer; Hu, Xiaolin; Al-Hemyari, Kadhair; McCarthy, Kevin; Domash, Lawrence; Hudgings, Janice A.

    2011-09-01

    Thermoreflectance imaging is shown to be a high resolution, non-contact method of quantitatively characterizing device performance and identifying electrical shunts in conventional multicrystalline silicon solar cells. Results are in quantitative agreement with a commercial lock-in infrared thermography system but offer an order of magnitude improvement in spatial resolution. Highly resolved thermoreflectance imaging enables extraction of quantitative, spatially resolved device performance characteristics, including local IV curves and local diode ideality factors, offering detailed physical characterization of performance-limiting defects that cannot be obtained from conventional bulk cell testing. Finally, thermoreflectance maps of heat spreading from a point defect provide a simple means of quantifying thermal parameters such as thermal diffusivity and thermal conductivity, which are key field performance indicators.

  20. Impulse Response Estimation for Spatial Resolution Enhancement in Ultrasonic NDE Imaging

    SciTech Connect

    Clark, G A

    2004-06-25

    This report describes a signal processing algorithm and MATLAB software for improving spatial resolution in ultrasonic nondestructive evaluation (NDE) imaging of materials. Given a measured reflection signal and an associated reference signal, the algorithm produces an optimal least-squares estimate of the impulse response of the material under test. This estimated impulse response, when used in place of the raw reflection signal, enhances the spatial resolution of the ultrasonic measurements by removing distortion caused by the limited-bandwidth transducers and the materials under test. The theory behind the processing algorithms is briefly presented, while the reader is referred to the bibliography for details. The main focus of the report is to describe how to use the MATLAB software. Two processing examples using actual ultrasonic measurements are provided for tutorial purposes.

  1. The application of high spectral and spatial resolution imaging spectrometers for locating downed aircraft

    NASA Technical Reports Server (NTRS)

    Gatlin, James A.; Middleton, Elizabeth M.; Irons, James R.; Robinson, Jon W.

    1991-01-01

    The utility of high-resolution imaging spectrometer data is examined as an aid in locating downed aircraft by using a unique spectral signature while not requiring the extremely high spatial resolution needed to identify an aircraft by shape. Ground spectral measurements of several airplane wings, overflight spectral measurements of aircraft scenes, and the rationale for the chosen spectral signature are presented. It is concluded that imaging spectrometers which can detect and spatially locate a narrow-band spectral signature filling only a few pixels appear to have a utility for search and rescue aircraft or satellite systems as a aid in locating small downed aircraft. This spectral feature would have to be added to the surface coatings applied to aircraft. Proposed for use as such a spectral signature is a significant negative reflectance slope, in the 520 to 580 nm interval.

  2. Spatial resolution of imaging plate with flash X-rays and its utilization for radiography

    SciTech Connect

    Shaikh, A. M.; Romesh, C.; Kolage, T. S.; Sharma, Archana

    2015-06-24

    A flash X-ray source developed using pulsed electron accelerator with electron energy range of 400keV to 1030keV and a field emission cathode is characterized using X-ray imaging plates. Spatial resolution of the imaging system is measured using edge spread function fitted to data obtained from radiograph of Pb step wedge. A spatial resolution of 150±6 µm is obtained. The X-ray beam size is controlled by the anode-cathode configuration. Optimum source size of ∼13±2 mm diameter covering an area with intensity of ∼27000 PSL/mm{sup 2} is obtained on the imaging plate kept at a distance of ∼200 mm from the tip of the anode. It is used for recording radiographs of objects like satellite cable cutter, aero-engine turbine blade and variety of pyro-devices used in aerospace industry.

  3. Spatial resolution of imaging plate with flash X-rays and its utilization for radiography

    NASA Astrophysics Data System (ADS)

    Shaikh, A. M.; Romesh, C.; Kolage, T. S.; Sharma, Archana

    2015-06-01

    A flash X-ray source developed using pulsed electron accelerator with electron energy range of 400keV to 1030keV and a field emission cathode is characterized using X-ray imaging plates. Spatial resolution of the imaging system is measured using edge spread function fitted to data obtained from radiograph of Pb step wedge. A spatial resolution of 150±6 µm is obtained. The X-ray beam size is controlled by the anode-cathode configuration. Optimum source size of ˜13±2 mm diameter covering an area with intensity of ˜27000 PSL/mm2 is obtained on the imaging plate kept at a distance of ˜200 mm from the tip of the anode. It is used for recording radiographs of objects like satellite cable cutter, aero-engine turbine blade and variety of pyro-devices used in aerospace industry

  4. Working memory-driven attention improves spatial resolution: Support for perceptual enhancement.

    PubMed

    Pan, Yi; Luo, Qianying; Cheng, Min

    2016-08-01

    Previous research has indicated that attention can be biased toward those stimuli matching the contents of working memory and thereby facilitates visual processing at the location of the memory-matching stimuli. However, whether this working memory-driven attentional modulation takes place on early perceptual processes remains unclear. Our present results showed that working memory-driven attention improved identification of a brief Landolt target presented alone in the visual field. Because the suprathreshold target appeared without any external noise added (i.e., no distractors or masks), the results suggest that working memory-driven attention enhances the target signal at early perceptual stages of visual processing. Furthermore, given that performance in the Landolt target identification task indexes spatial resolution, this attentional facilitation indicates that working memory-driven attention can boost early perceptual processing via enhancement of spatial resolution at the attended location.

  5. Micro mirror arrays as high-resolution spatial light modulators for photoactivation and optogenetics

    NASA Astrophysics Data System (ADS)

    Rückerl, F.; Kielhorn, Martin; Tinevez, J.-Y.; Heber, J.; Heintzmann, R.; Shorte, S.

    2013-03-01

    The ability to control the illumination and imaging paths of optical microscopes is an essential part of advanced fluorescence microscopy, and a powerful tool for optogenetics. In order to maximize the visualization and the image quality of the objects under observation we use programmable, fast Micro Mirror Arrays (MMAs) as high-resolution Spatial Light Modulators (SLMs). Using two 256x256 MMAs in a mirror-based illumination setup allows for fast angular-spatial control at a wide range of wavelengths (300-1000nm). Additionally, the illumination intensity can be controlled at 10-bit resolution. The setup allows selective illumination of subcellular regions of interest enabling the precise, localized activation of fluorescent probes and the activation and deactivation of subcellular and cellular signaling cascades using photo-activated ion-channels. Furthermore, inasmuch as phototoxicity is dependent on the rate of photo illumination [1] we show that our system, which provides fast, compartmentalized illumination is minimally phototoxic.

  6. Measurement Sets and Sites Commonly Used for High Spatial Resolution Image Product Characterization

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary

    2006-01-01

    Scientists within NASA's Applied Sciences Directorate have developed a well-characterized remote sensing Verification & Validation (V&V) site at the John C. Stennis Space Center (SSC). This site has enabled the in-flight characterization of satellite high spatial resolution remote sensing system products form Space Imaging IKONOS, Digital Globe QuickBird, and ORBIMAGE OrbView, as well as advanced multispectral airborne digital camera products. SSC utilizes engineered geodetic targets, edge targets, radiometric tarps, atmospheric monitoring equipment and their Instrument Validation Laboratory to characterize high spatial resolution remote sensing data products. This presentation describes the SSC characterization capabilities and techniques in the visible through near infrared spectrum and examples of calibration results.

  7. The sensitivity of landscape evolution models to spatial and temporal rainfall resolution

    NASA Astrophysics Data System (ADS)

    Coulthard, Tom J.; Skinner, Christopher J.

    2016-09-01

    Climate is one of the main drivers for landscape evolution models (LEMs), yet its representation is often basic with values averaged over long time periods and frequently lumped to the same value for the whole basin. Clearly, this hides the heterogeneity of precipitation - but what impact does this averaging have on erosion and deposition, topography, and the final shape of LEM landscapes? This paper presents results from the first systematic investigation into how the spatial and temporal resolution of precipitation affects LEM simulations of sediment yields and patterns of erosion and deposition. This is carried out by assessing the sensitivity of the CAESAR-Lisflood LEM to different spatial and temporal precipitation resolutions - as well as how this interacts with different-size drainage basins over short and long timescales. A range of simulations were carried out, varying rainfall from 0.25 h × 5 km to 24 h × Lump resolution over three different-sized basins for 30-year durations. Results showed that there was a sensitivity to temporal and spatial resolution, with the finest leading to > 100 % increases in basin sediment yields. To look at how these interactions manifested over longer timescales, several simulations were carried out to model a 1000-year period. These showed a systematic bias towards greater erosion in uplands and deposition in valley floors with the finest spatial- and temporal-resolution data. Further tests showed that this effect was due solely to the data resolution, not orographic factors. Additional research indicated that these differences in sediment yield could be accounted for by adding a compensation factor to the model sediment transport law. However, this resulted in notable differences in the topographies generated, especially in third-order and higher streams. The implications of these findings are that uncalibrated past and present LEMs using lumped and time-averaged climate inputs may be under-predicting basin sediment

  8. Quantitative metrics for assessment of chemical image quality and spatial resolution

    DOE PAGES

    Kertesz, Vilmos; Cahill, John F.; Van Berkel, Gary J.

    2016-02-28

    Rationale: Currently objective/quantitative descriptions of the quality and spatial resolution of mass spectrometry derived chemical images are not standardized. Development of these standardized metrics is required to objectively describe chemical imaging capabilities of existing and/or new mass spectrometry imaging technologies. Such metrics would allow unbiased judgment of intra-laboratory advancement and/or inter-laboratory comparison for these technologies if used together with standardized surfaces. Methods: We developed two image metrics, viz., chemical image contrast (ChemIC) based on signal-to-noise related statistical measures on chemical image pixels and corrected resolving power factor (cRPF) constructed from statistical analysis of mass-to-charge chronograms across features of interest inmore » an image. These metrics, quantifying chemical image quality and spatial resolution, respectively, were used to evaluate chemical images of a model photoresist patterned surface collected using a laser ablation/liquid vortex capture mass spectrometry imaging system under different instrument operational parameters. Results: The calculated ChemIC and cRPF metrics determined in an unbiased fashion the relative ranking of chemical image quality obtained with the laser ablation/liquid vortex capture mass spectrometry imaging system. These rankings were used to show that both chemical image contrast and spatial resolution deteriorated with increasing surface scan speed, increased lane spacing and decreasing size of surface features. Conclusions: ChemIC and cRPF, respectively, were developed and successfully applied for the objective description of chemical image quality and spatial resolution of chemical images collected from model surfaces using a laser ablation/liquid vortex capture mass spectrometry imaging system.« less

  9. An optical setup for electric field measurements in MRI with high spatial resolution

    NASA Astrophysics Data System (ADS)

    Reiss, Simon; Bitzer, Andreas; Bock, Michael

    2015-06-01

    Electric field measurements in the magnetic resonance (MR) imaging environment are important to assess potentially dangerous radio-frequency (RF) heating in the vicinity of metallic structures such as coils, implants or catheters. So far, E-field measurements have been performed with dipole antennas that lag of limited spatial resolution and which are difficult to use in the magnet bore as they interfere with the RF transmit field of the MRI system. In this work an electro-optic sensor is presented that utilizes the Pockels effect to measure the E-field in a clinical MR system with high spatial resolution. This sensor consists of dielectric materials only and thus, it only minimally influences the measured E-field distribution. A 10 m long flexible optical fiber connects the small sensor head to a remote processing unit where the optical signal is transformed into an electrical output signal. Spatially resolved qualitative E-field measurements were performed in a 1.5 T clinical MR system in the vicinity of metallic samples and an active tracking catheter with a resolution of up to 1 mm. The near-field pattern of a resonant U-shaped metallic sample was clearly identified and compared with numerical simulations. A more complex field behavior was found for the tracking catheter where strong E-field enhancements were observed at the distal tip and at its proximal part outside the phantom solution. Due to its sub-mm spatial resolution the optical sensor approach provides detailed insight into the complex and difficult to access field distributions close to implants and metallic structures and has turned out to be promising tool for MRI field and safety inspections.

  10. An optical setup for electric field measurements in MRI with high spatial resolution.

    PubMed

    Reiss, Simon; Bitzer, Andreas; Bock, Michael

    2015-06-01

    Electric field measurements in the magnetic resonance (MR) imaging environment are important to assess potentially dangerous radio-frequency (RF) heating in the vicinity of metallic structures such as coils, implants or catheters. So far, E-field measurements have been performed with dipole antennas that lag of limited spatial resolution and which are difficult to use in the magnet bore as they interfere with the RF transmit field of the MRI system. In this work an electro-optic sensor is presented that utilizes the Pockels effect to measure the E-field in a clinical MR system with high spatial resolution. This sensor consists of dielectric materials only and thus, it only minimally influences the measured E-field distribution. A 10 m long flexible optical fiber connects the small sensor head to a remote processing unit where the optical signal is transformed into an electrical output signal. Spatially resolved qualitative E-field measurements were performed in a 1.5 T clinical MR system in the vicinity of metallic samples and an active tracking catheter with a resolution of up to 1 mm. The near-field pattern of a resonant U-shaped metallic sample was clearly identified and compared with numerical simulations. A more complex field behavior was found for the tracking catheter where strong E-field enhancements were observed at the distal tip and at its proximal part outside the phantom solution. Due to its sub-mm spatial resolution the optical sensor approach provides detailed insight into the complex and difficult to access field distributions close to implants and metallic structures and has turned out to be promising tool for MRI field and safety inspections. PMID:25984961

  11. Quantitative coherent diffractive imaging of an integrated circuit at a spatial resolution of 20 nm

    NASA Astrophysics Data System (ADS)

    Abbey, Brian; Williams, Garth J.; Pfeifer, Mark A.; Clark, Jesse N.; Putkunz, Corey T.; Torrance, Angela; McNulty, Ian; Levin, T. M.; Peele, Andrew G.; Nugent, Keith A.

    2008-11-01

    The complex transmission function of an integrated circuit is reconstructed at 20 nm spatial resolution using coherent diffractive imaging. A quantitative map is made of the exit surface wave emerging from void defects within the circuit interconnect. Assuming a known index of refraction for the substrate allows the volume of these voids to be estimated from the phase retardation in this region. Sample scanning and tomography of extended objects using coherent diffractive imaging is demonstrated.

  12. Radiometric Calibration Assessment of Commercial High Spatial Resolution Multispectral Image Products

    NASA Technical Reports Server (NTRS)

    Thome, Kurt; Leisso, Nathan; Buchanan, John

    2007-01-01

    This paper describes the results of commercial high spatial resolution sensors. The topics include: 1) Reflectance-based approach; 2) U of A test sites; 3) Test Site Selection; 4) Resort Living; 5) Aerosol parameters; 6) Surface reflectance retrieval; 7) Accuracy/precision; 8) Data sets; 9) June 23, 2005 for Ikonos; 10) QuickBird Results; 11) Ikonos results; 12) Orbview results; 13) Ikonos redux; and 14) Overall results.

  13. Improving detector spatial resolution using pixelated scintillators with a barrier rib structure

    NASA Astrophysics Data System (ADS)

    Liu, Langechuan; Lu, Minghui; Cao, Wanqing; Peng, Luke; Chen, Arthur

    2016-03-01

    Indirect conversion flat panel detectors (FPDs) based on amorphous silicon (a-Si) technology are widely used in digital X-ray imaging. In such FPDs a scintillator layer is used for converting X-rays into visible light photons. However, the lateral spread of these photons inside the scintillator layer reduces spatial resolution of the FPD. In this study, FPDs incorporating pixelated scintillators with a barrier rib structure were developed to limit lateral spread of light photons thereby improving spatial resolution. For the pixelated scintillator, a two-dimensional barrier rib structure was first manufactured on a substrate layer, coated with reflective materials, and filled to the rim with the scintillating material of gadolinium oxysulfide (GOS). Several scintillator samples were fabricated, with pitch size varying from 160 to 280 μm and rib height from 200 to 280 μm. The samples were directly coupled to an a-Si flat panel photodiode array with a pitch of 200 μm to convert optical photons to electronic signals. With the pixelated scintillator, the detector modulation transfer function was shown to improve significantly (by 94% at 2 cycle/mm) compared to a detector using an unstructured GOS layer. However, the prototype does show lower sensitivity due to the decrease in scintillator fill factor. The preliminary results demonstrated the feasibility of using the barrier-rib structure to improve the spatial resolution of FPDs. Such an improvement would greatly benefit nondestructive testing applications where the spatial resolution is the most important parameter. Further investigation will focus on improving the detector sensitivity and exploring its medical applications.

  14. High-resolution wavefront control using liquid crystal spatial light modulators

    SciTech Connect

    Bauman, B J; Brase, J M; Brown, C G; Cooke, J B; Kartz, M W; Olivier, S S; Pennington, D M; Silva, D A

    1999-07-20

    Liquid crystal spatial light modulator technology appropriate for high-resolution wavefront control has recently become commercially available. Some of these devices have several hundred thousand controllable degrees of freedom, more than two orders of magnitude greater than the largest conventional deformable mirror. We will present results of experiments to characterize the optical properties of these devices and to utilize them to correct aberrations in an optical system. We will also present application scenarios for these devices in high-power laser systems.

  15. Effects of asymmetric photopeak windows on flood field uniformity and spatial resolution of scintillation cameras.

    PubMed

    Graham, L S; LaFontaine, R L; Stein, M A

    1986-05-01

    Pulse height analyzer windows that are set on the high side of the photopeak are known to improve spatial resolution and contrast when used for scintillation camera imaging. Asymmetric windows can be used with some scintillation cameras that have energy correction circuitry. In this study the improvement in spatial resolution and loss of field uniformity for 99mTc, 201Tl, and 131I were measured as a function of window asymmetry (up to 30%, defined relative to the loss of counts as compared to a symmetric window under intrinsic conditions). Flood field uniformity was inversely related to the degree of window asymmetry. With 10 cm of scatter the 99mTc integral uniformity deteriorated from 7.9% with a symmetric window to 11.5% for a 30% asymmetric window. The corresponding values for 201Tl were 9.9 and 10.9%. Even without additional scatter, the values for 131I were 23.0 and 26.5%. Spatial resolution, as measured by the full width at half maximum in 10 cm of scatter improved by only 5% for 99mTc and 7% for 201Tl. However, the full width at tenth maximum increased by as much as 20% for 99mTc and 201Tl. A large percentage of this improvement was attained with small degrees of asymmetry. This study demonstrates that 10% or less asymmetry can provide most of the benefit in spatial resolution and contrast that is to be gained without significant losses in field uniformity and count rate.

  16. A spatial-temporal Hopfield neural network approach for super-resolution land cover mapping with multi-temporal different resolution remotely sensed images

    NASA Astrophysics Data System (ADS)

    Li, Xiaodong; Ling, Feng; Du, Yun; Feng, Qi; Zhang, Yihang

    2014-07-01

    The mixed pixel problem affects the extraction of land cover information from remotely sensed images. Super-resolution mapping (SRM) can produce land cover maps with a finer spatial resolution than the remotely sensed images, and reduce the mixed pixel problem to some extent. Traditional SRMs solely adopt a single coarse-resolution image as input. Uncertainty always exists in resultant fine-resolution land cover maps, due to the lack of information about detailed land cover spatial patterns. The development of remote sensing technology has enabled the storage of a great amount of fine spatial resolution remotely sensed images. These data can provide fine-resolution land cover spatial information and are promising in reducing the SRM uncertainty. This paper presents a spatial-temporal Hopfield neural network (STHNN) based SRM, by employing both a current coarse-resolution image and a previous fine-resolution land cover map as input. STHNN considers the spatial information, as well as the temporal information of sub-pixel pairs by distinguishing the unchanged, decreased and increased land cover fractions in each coarse-resolution pixel, and uses different rules in labeling these sub-pixels. The proposed STHNN method was tested using synthetic images with different class fraction errors and real Landsat images, by comparing with pixel-based classification method and several popular SRM methods including pixel-swapping algorithm, Hopfield neural network based method and sub-pixel land cover change mapping method. Results show that STHNN outperforms pixel-based classification method, pixel-swapping algorithm and Hopfield neural network based model in most cases. The weight parameters of different STHNN spatial constraints, temporal constraints and fraction constraint have important functions in the STHNN performance. The heterogeneity degree of the previous map and the fraction images errors affect the STHNN accuracy, and can be served as guidances of selecting the

  17. Effect of Spatial Resolution for Characterizing Soil Properties from Imaging Spectrometer Data

    NASA Astrophysics Data System (ADS)

    Dutta, D.; Kumar, P.; Greenberg, J. A.

    2015-12-01

    The feasibility of quantifying soil constituents over large areas using airborne hyperspectral data [0.35 - 2.5 μm] in an ensemble bootstrapping lasso algorithmic framework has been demonstrated previously [1]. However the effects of coarsening the spatial resolution of hyperspectral data on the quantification of soil constituents are unknown. We use Airborne Visible Infrared Imaging Spectrometer (AVIRIS) data collected at 7.6m resolution over Birds Point New Madrid (BPNM) floodway for up-scaling and generating multiple coarser resolution datasets including the 60m Hyperspectral Infrared Imager (HyspIRI) like data. HyspIRI is a proposed visible shortwave/thermal infrared mission, which will provide global data over a spectral range of 0.35 - 2.5μm at a spatial resolution of 60m. Our results show that the lasso method, which is based on point scale observational data, is scalable. We found consistent good model performance (R2) values (0.79 < R2 < 0.82) and correct classifications as per USDA soil texture classes at multiple spatial resolutions. The results further demonstrate that the attributes of the pdf for different soil constituents across the landscape and the within-pixel variance are well preserved across scales. Our analysis provides a methodological framework with a sufficient set of metrics for assessing the performance of scaling up analysis from point scale observational data and may be relevant for other similar remote sensing studies. [1] Dutta, D.; Goodwell, A.E.; Kumar, P.; Garvey, J.E.; Darmody, R.G.; Berretta, D.P.; Greenberg, J.A., "On the Feasibility of Characterizing Soil Properties From AVIRIS Data," Geoscience and Remote Sensing, IEEE Transactions on, vol.53, no.9, pp.5133,5147, Sept. 2015. doi: 10.1109/TGRS.2015.2417547.

  18. Generation of remotely sensed reference data using low altitude, high spatial resolution hyperspectral imagery

    NASA Astrophysics Data System (ADS)

    Williams, McKay D.; van Aardt, Jan; Kerekes, John P.

    2016-05-01

    Exploitation of imaging spectroscopy (hyperspectral) data using classification and spectral unmixing algorithms is a major research area in remote sensing, with reference data required to assess algorithm performance. However, we are limited by our inability to generate rapid, accurate, and consistent reference data, thus making quantitative algorithm analysis difficult. As a result, many investigators present either limited quantitative results, use synthetic imagery, or provide qualitative results using real imagery. Existing reference data typically classify large swaths of imagery pixel-by-pixel, per cover type. While this type of mapping provides a first order understanding of scene composition, it is not detailed enough to include complexities such as mixed pixels, intra-end-member variability, and scene anomalies. The creation of more detailed ground reference data based on field work, on the other hand, is complicated by the spatial scale of common hyperspectral data sets. This research presents a solution to this challenge via classification of low altitude, high spatial resolution (1m GSD) National Ecological Observatory Network (NEON) hyperspectral imagery, on a pixel-by-pixel basis, to produce sub-pixel reference data for high altitude, lower spatial resolution (15m GSD) AVIRIS imagery. This classification is performed using traditional classification techniques, augmented by (0.3m GSD) NEON RGB data. This paper provides a methodology for generating large scale, sub-pixel reference data for AVIRIS imagery using NEON imagery. It also addresses challenges related to the fusion of multiple remote sensing modalities (e.g., different sensors, sensor look angles, spatial registration, varying scene illumination, etc.). A new algorithm for spatial registration of hyperspectral imagery with disparate resolutions is presented. Several versions of reference data results are compared to each other and to direct spectral unmixing of AVIRIS data. Initial results are

  19. Detection of Local Anomalies in High Resolution Hyperspectral Imagery Using Geostatistical Filtering and Local Spatial Statistics

    NASA Astrophysics Data System (ADS)

    Goovaerts, P.; Jacquez, G. M.; Marcus, A. W.

    2004-12-01

    Spatial data are periodically collected and processed to monitor, analyze and interpret developments in our changing environment. Remote sensing is a modern way of data collecting and has seen an enormous growth since launching of modern satellites and development of airborne sensors. In particular, the recent availability of high spatial resolution hyperspectral imagery (spatial resolution of less than 5 meters and including data collected over 64 or more bands of electromagnetic radiation for each pixel offers a great potential to significantly enhance environmental mapping and our ability to model spatial systems. High spatial resolution imagery contains a remarkable quantity of information that could be used to analyze spatial breaks (boundaries), areas of similarity (clusters), and spatial autocorrelation (associations) across the landscape. This paper addresses the specific issue of soil disturbance detection, which could indicate the presence of land mines or recent movements of troop and heavy equipment. A challenge presented by soil detection is to retain the measurement of fine-scale features (i.e. mineral soil changes, organic content changes, vegetation disturbance related changes, aspect changes) while still covering proportionally large spatial areas. An additional difficulty is that no ground data might be available for the calibration of spectral signatures, and little might be known about the size of patches of disturbed soils to be detected. This paper describes a new technique for automatic target detection which capitalizes on both spatial and across spectral bands correlation, does not require any a priori information on the target spectral signature but does not allow discrimination between targets. This approach involves successively a multivariate statistical analysis (principal component analysis) of all spectral bands, a geostatistical filtering of noise and regional background in the first principal components using factorial kriging, and

  20. Influence of tip geometry on the spatial resolution of tip enhanced Raman mapping

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Chen, Bao-Qin; Li, Zhi-Yuan

    2016-09-01

    In 2013, a breakthrough experiment pushed the Raman mapping of molecules via the tip-enhanced Raman scattering (TERS) technique to a sub-nanometer spatial resolution, going into the single-molecule level. This surprising result was well explained by accounting for the critical role of elastic molecule Rayleigh scattering within a plasmonic nanogap in enhancing both the localization and the intensity level of the Raman scattering signal. In this paper, we theoretically explore the influence of various geometric factors of the TERS system on the spatial resolution of Raman mapping, such as the tip curvature radius, tip conical angle, tip–substrate distance, and tip–molecule vertical distance. This investigation can help to find out the most critical geometric factor influencing the spatial resolution of TERS and march along in the right direction for further improving the performance of the TERS system. Project supported by the National Natural Science Foundation of China (Grant No. 11434017) and the National Basic Research Program of China (Grant No. 2013CB632704).

  1. Influence of tip geometry on the spatial resolution of tip enhanced Raman mapping

    NASA Astrophysics Data System (ADS)

    Zhang, Chao; Chen, Bao-Qin; Li, Zhi-Yuan

    2016-09-01

    In 2013, a breakthrough experiment pushed the Raman mapping of molecules via the tip-enhanced Raman scattering (TERS) technique to a sub-nanometer spatial resolution, going into the single-molecule level. This surprising result was well explained by accounting for the critical role of elastic molecule Rayleigh scattering within a plasmonic nanogap in enhancing both the localization and the intensity level of the Raman scattering signal. In this paper, we theoretically explore the influence of various geometric factors of the TERS system on the spatial resolution of Raman mapping, such as the tip curvature radius, tip conical angle, tip-substrate distance, and tip-molecule vertical distance. This investigation can help to find out the most critical geometric factor influencing the spatial resolution of TERS and march along in the right direction for further improving the performance of the TERS system. Project supported by the National Natural Science Foundation of China (Grant No. 11434017) and the National Basic Research Program of China (Grant No. 2013CB632704).

  2. Fourier transform infrared absorption spectroscopy characterization of gaseous atmospheric pressure plasmas with 2 mm spatial resolution

    SciTech Connect

    Laroche, G.; Vallade, J.; Bazinette, R.; Hernandez, E.; Hernandez, G.; Massines, F.; Nijnatten, P. van

    2012-10-15

    This paper describes an optical setup built to record Fourier transform infrared (FTIR) absorption spectra in an atmospheric pressure plasma with a spatial resolution of 2 mm. The overall system consisted of three basic parts: (1) optical components located within the FTIR sample compartment, making it possible to define the size of the infrared beam (2 mm Multiplication-Sign 2 mm over a path length of 50 mm) imaged at the site of the plasma by (2) an optical interface positioned between the spectrometer and the plasma reactor. Once through the plasma region, (3) a retro-reflector module, located behind the plasma reactor, redirected the infrared beam coincident to the incident path up to a 45 Degree-Sign beamsplitter to reflect the beam toward a narrow-band mercury-cadmium-telluride detector. The antireflective plasma-coating experiments performed with ammonia and silane demonstrated that it was possible to quantify 42 and 2 ppm of these species in argon, respectively. In the case of ammonia, this was approximately three times less than this gas concentration typically used in plasma coating experiments while the silane limit of quantification was 35 times lower. Moreover, 70% of the incoming infrared radiation was focused within a 2 mm width at the site of the plasma, in reasonable agreement with the expected spatial resolution. The possibility of reaching this spatial resolution thus enabled us to measure the gaseous precursor consumption as a function of their residence time in the plasma.

  3. Energy-filtering TEM at high magnification: spatial resolution and detection limits.

    PubMed

    Grogger, Werner; Schaffer, Bernhard; Krishnan, Kannan M; Hofer, Ferdinand

    2003-09-01

    Energy-filtering TEM (EFTEM) has turned out to be a very efficient and rapid tool for the chemical characterization of a specimen on a nanometer and even subnanometer length scale. Especially, the detection and measurement of very thin layers has become a great application of this technique in many materials science fields, e.g. semiconductors and hard disk technology. There, the reliability of compositional profiles is an important issue. However, the experimentally obtainable spatial resolution strongly influences the appearance of a thin layer in an EFTEM image, when dimensions reach subnanometer levels, which mainly leads to a broadening of the layer in the image. This fact has to be taken into account, when measuring the thickness of such a thin layer. Additionally, the convolution decreases contrast which makes the layer less visible in the image and finally determines the detection limit. In this work we present a systematic study on specifically designed Mn/PdMn multilayer test specimens to explore the practical aspects of spatial resolution and detection limits in EFTEM. Although specific to the ionization edges used, we will present general conclusions about the practical limitations in terms of EFTEM spatial resolution. Additionally, work will be shown about low energy-loss imaging of thin oxide layers, where delocalization is the main factor responsible for broadening. PMID:12871810

  4. fMRI at High Spatial Resolution: Implications for BOLD-Models.

    PubMed

    Goense, Jozien; Bohraus, Yvette; Logothetis, Nikos K

    2016-01-01

    As high-resolution functional magnetic resonance imaging (fMRI) and fMRI of cortical layers become more widely used, the question how well high-resolution fMRI signals reflect the underlying neural processing, and how to interpret laminar fMRI data becomes more and more relevant. High-resolution fMRI has shown laminar differences in cerebral blood flow (CBF), volume (CBV), and neurovascular coupling. Features and processes that were previously lumped into a single voxel become spatially distinct at high resolution. These features can be vascular compartments such as veins, arteries, and capillaries, or cortical layers and columns, which can have differences in metabolism. Mesoscopic models of the blood oxygenation level dependent (BOLD) response therefore need to be expanded, for instance, to incorporate laminar differences in the coupling between neural activity, metabolism and the hemodynamic response. Here we discuss biological and methodological factors that affect the modeling and interpretation of high-resolution fMRI data. We also illustrate with examples from neuropharmacology and the negative BOLD response how combining BOLD with CBF- and CBV-based fMRI methods can provide additional information about neurovascular coupling, and can aid modeling and interpretation of high-resolution fMRI.

  5. fMRI at High Spatial Resolution: Implications for BOLD-Models

    PubMed Central

    Goense, Jozien; Bohraus, Yvette; Logothetis, Nikos K.

    2016-01-01

    As high-resolution functional magnetic resonance imaging (fMRI) and fMRI of cortical layers become more widely used, the question how well high-resolution fMRI signals reflect the underlying neural processing, and how to interpret laminar fMRI data becomes more and more relevant. High-resolution fMRI has shown laminar differences in cerebral blood flow (CBF), volume (CBV), and neurovascular coupling. Features and processes that were previously lumped into a single voxel become spatially distinct at high resolution. These features can be vascular compartments such as veins, arteries, and capillaries, or cortical layers and columns, which can have differences in metabolism. Mesoscopic models of the blood oxygenation level dependent (BOLD) response therefore need to be expanded, for instance, to incorporate laminar differences in the coupling between neural activity, metabolism and the hemodynamic response. Here we discuss biological and methodological factors that affect the modeling and interpretation of high-resolution fMRI data. We also illustrate with examples from neuropharmacology and the negative BOLD response how combining BOLD with CBF- and CBV-based fMRI methods can provide additional information about neurovascular coupling, and can aid modeling and interpretation of high-resolution fMRI. PMID:27445782

  6. fMRI at High Spatial Resolution: Implications for BOLD-Models.

    PubMed

    Goense, Jozien; Bohraus, Yvette; Logothetis, Nikos K

    2016-01-01

    As high-resolution functional magnetic resonance imaging (fMRI) and fMRI of cortical layers become more widely used, the question how well high-resolution fMRI signals reflect the underlying neural processing, and how to interpret laminar fMRI data becomes more and more relevant. High-resolution fMRI has shown laminar differences in cerebral blood flow (CBF), volume (CBV), and neurovascular coupling. Features and processes that were previously lumped into a single voxel become spatially distinct at high resolution. These features can be vascular compartments such as veins, arteries, and capillaries, or cortical layers and columns, which can have differences in metabolism. Mesoscopic models of the blood oxygenation level dependent (BOLD) response therefore need to be expanded, for instance, to incorporate laminar differences in the coupling between neural activity, metabolism and the hemodynamic response. Here we discuss biological and methodological factors that affect the modeling and interpretation of high-resolution fMRI data. We also illustrate with examples from neuropharmacology and the negative BOLD response how combining BOLD with CBF- and CBV-based fMRI methods can provide additional information about neurovascular coupling, and can aid modeling and interpretation of high-resolution fMRI. PMID:27445782

  7. Theoretical limit of spatial resolution in diffuse optical tomography using a perturbation model

    SciTech Connect

    Konovalov, A B; Vlasov, V V

    2014-03-28

    We have assessed the limit of spatial resolution of timedomain diffuse optical tomography (DOT) based on a perturbation reconstruction model. From the viewpoint of the structure reconstruction accuracy, three different approaches to solving the inverse DOT problem are compared. The first approach involves reconstruction of diffuse tomograms from straight lines, the second – from average curvilinear trajectories of photons and the third – from total banana-shaped distributions of photon trajectories. In order to obtain estimates of resolution, we have derived analytical expressions for the point spread function and modulation transfer function, as well as have performed a numerical experiment on reconstruction of rectangular scattering objects with circular absorbing inhomogeneities. It is shown that in passing from reconstruction from straight lines to reconstruction using distributions of photon trajectories we can improve resolution by almost an order of magnitude and exceed the accuracy of reconstruction of multi-step algorithms used in DOT. (optical tomography)

  8. High spatial and temporal resolution phase contrast imaging of shock wave using the LCLS beam

    NASA Astrophysics Data System (ADS)

    Lee, Hae Ja; Galtier, E.; Nagler, B.; Schropp, A.; Hastings, J. B.; Lee, R. W.; Collins, G. W.; Ping, Y.; Schroer, C. G.

    2012-10-01

    A new technique using the Linac Coherent Light Source (LCLS), the x-ray free electron laser source, was developed at Matter in Extreme Conditions (MEC) endstation to provide high spatial and temporal resolution phase contrast imaging of shock waves in matter. The LCLS has high peak brightness enabling a high beam current of a few mJ/pulse to be focused into a small spot to achieve high imaging resolution < 1 μm. 150 ps, 140 mJ, 800 nm short pulse laser beam was focused to produce shock waves in a material. We collected the first high resolution phase contrast movies of shock propagation inside materials. These results provide the first in-situ imaging of the shock front width, deformation length and time scale behind the shock of materials with free electron laser.

  9. The analysis of high spatial resolution UV and X-ray images by computational modeling. [coronagraphs

    NASA Technical Reports Server (NTRS)

    Vesecky, J. F.; Antiochos, S. K.; Underwood, J. H.

    1978-01-01

    Very high resolution stereoscopic images of high temperature loop structures observed at UV and X-ray wavelengths in the solar corona can be used to understand physical processes in the corona. An existing computational model is described and sample results are given to demonstrate that computational modeling of coronal structures can indeed take advantage of very high resolution images. The sample results include the run of temperature and number density along a typical loop and the variation of the differential emission measure with temperature. The integration of the differential emission measure with temperature along a column commensurate with an instrument's spatial resolution is the relevant parameter obtained from UV and X-ray observations. The effects of loop geometry and energy input are examined.

  10. High-resolution heteronuclear correlation spectroscopy based on spatial encoding and coherence transfer in inhomogeneous fields

    NASA Astrophysics Data System (ADS)

    Wang, Kaiyu; Zhang, Zhiyong; Chen, Hao; Cai, Shuhui; Chen, Zhong

    2015-11-01

    Two-dimensional (2D) nuclear magnetic resonance (NMR) spectroscopy has been proven to be a powerful technique for chemical, biological, and medical studies. Heteronuclear single quantum correlation (HSQC) and heteronuclear multiple bond correlation (HMBC) are two frequently used 2D NMR methods. In combination with spatially encoded techniques, a heteronuclear 2D NMR spectrum can be acquired in several seconds and may be applied to monitoring chemical reactions. However, it is difficult to obtain high-resolution NMR spectra in inhomogeneous fields. Inspired by the idea of tracing the difference of precession frequencies between two different spins to yield high-resolution spectra, we propose a method with correlation acquisition option and J-resolved-like acquisition option to ultrafast obtain high-resolution HSQC/HMBC spectra and heteronuclear J-resolved-like spectra in inhomogeneous fields.

  11. Beyond spicule dynamics: spicule and fibril spectroscopy at high spatial and temporal resolution

    NASA Astrophysics Data System (ADS)

    Mendes Domingos Pereira, T.; Rouppe van der Voort, L.

    2015-12-01

    Solar spicules are chromospheric fibrils observed at the solar limb. They are observed everywhere in the Sun, but their origin is not yet understood. Much of our understanding of spicules has been obtained through filtergram observations and/or focused on the dynamics of spicules. Spectroscopic studies have been usually limited by spatial extent/resolution, temporal resolution, or variable seeing. In this work we make use of a unique time series of imaging spectroscopy at high spatial and temporal resolution, obtained with the Swedish Solar Telescope under excellent seeing and coordinated with the IRIS mission. With these data we characterize the evolution of spectra along quiet Sun fibrils and spicules, and discuss what makes them visible in filtergrams and sets them apart from other chromospheric fibrils. With combined H-alpha and Ca II H high-resolution observations we also discuss how spicules appear in these two lines, a long standing issue that has been interpreted in conflicting ways. Finally, using the wide range of IRIS diagnostics we put together the spectral evolution of spicules through the chromosphere and transition region.

  12. FREND neutron telescope for mapping the Martian water with fine spatial resolution

    NASA Astrophysics Data System (ADS)

    Mitrofanov, Igor; Malakhov, Alexey; Mokrousov, Maxim; Golovin, Dmitry; Fedosov, Fedor; Kozyrev, Alexandr; Lisov, Denis; Litvak, Maxim; Nikiforov, Sergey; Sanin, Anton; Tret'yakov, Vlad; Vostrukhin, Andrey

    2016-04-01

    The concept of Fine Resolution Exploration Neutron Detector (FREND) is presented, as the Russian contributed instrument for the first element of ESA ExoMars mission, the TGO. FREND is the neutron collimated telescope, which is capable to measure the prompt neutron radiation of Mars from the 400 km orbit with the spatial resolution of about 40 km. The flux of epithermal neutrons is known to depend on the content of water in the shallow subsurface about 1 meter, so such measurements could allow to study the ground water distribution with fine spatial resolution over the entire martian surface from 70 degrees of the north latitude down to 70 degree of the south latitude. The resolution of tens of km is necessary to characterize the particular relief features on the surface by the content of water in the soil. Such mapping data should resolve the water distribution within the Gale crater, which is necessary to explain the paradoxic difefrence between the estimated contents of water in this crater, as about 5% by HEND on the Mars Odyssy and the ground data about 2 -3 % by DAN on the Curiosity. Also, the FREND mapping data of the ground water should be useful for the landing site selection of future Mars rovers, such as ExoMars or Mars 2020.

  13. High-resolution digital holographic imaging by using a spatial light modulator

    NASA Astrophysics Data System (ADS)

    Li, Bin; Wang, Da-Yong; Wang, Yun-Xin; Rong, Lu

    2014-09-01

    Digital holography is the product of the optical holography, computer technology and photoelectric detection technology, and has the advantage of high-speed, real-time, full field of view, non-contact and quantitative phase contrast imaging. However, the numerical aperture of the hologram is limited due to the smaller sensitive area of the photoelectric sensor and the larger pixel size, and it is uneasy to meet the practical requirement on the imaging resolution. An approach is presented to achieve the high-resolution digital holographic imaging based on a spatial light modulator(SLM). An amplitude spatial light modulator is placed between the object and the CCD in the lensless Fourier transform digital holographic imaging system. The distribution of a diffraction grating is loaded into the SLM. In this way, more light including the high-frequency content, diffracted from the object, can be collected by the CCD. The standard resolution target is used as the object. The reconstructed image is obtained by the Fresnel diffraction propagation algorithm, which exhibits three diffraction orders. The results show that the resolution is improved from 62.5 μm to 31.3 μm.

  14. Application of Spatially Resolved High Resolution Crystal Spectrometry to ICF Plasmas

    SciTech Connect

    Kenneth W. Hill, et. al.

    2012-09-15

    High resolution (λ/Δ λ ~ 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-μm 55 Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10-8 -10-6 times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

  15. Application of spatially resolved high resolution crystal spectrometry to inertial confinement fusion plasmas

    SciTech Connect

    Hill, K. W.; Bitter, M.; Delgado-Aparacio, L.; Pablant, N. A.; Beiersdorfer, P.; Schneider, M.; Widmann, K.; Sanchez del Rio, M.; Zhang, L.

    2012-10-15

    High resolution ({lambda}/{Delta}{lambda}{approx} 10 000) 1D imaging x-ray spectroscopy using a spherically bent crystal and a 2D hybrid pixel array detector is used world wide for Doppler measurements of ion-temperature and plasma flow-velocity profiles in magnetic confinement fusion plasmas. Meter sized plasmas are diagnosed with cm spatial resolution and 10 ms time resolution. This concept can also be used as a diagnostic of small sources, such as inertial confinement fusion plasmas and targets on x-ray light source beam lines, with spatial resolution of micrometers, as demonstrated by laboratory experiments using a 250-{mu}m {sup 55}Fe source, and by ray-tracing calculations. Throughput calculations agree with measurements, and predict detector counts in the range 10{sup -8}-10{sup -6} times source x-rays, depending on crystal reflectivity and spectrometer geometry. Results of the lab demonstrations, application of the technique to the National Ignition Facility (NIF), and predictions of performance on NIF will be presented.

  16. Mapping urban and peri-urban agriculture using high spatial resolution satellite data

    NASA Astrophysics Data System (ADS)

    Forster, Dionys; Buehler, Yves; Kellenberger, Tobias W.

    2009-03-01

    In rapidly changing peri-urban environments where biophysical and socio-economic processes lead to spatial fragmentation of agricultural land, remote sensing offers an efficient tool to collect land cover/land use (LCLU) data for decision-making. Compared to traditional pixel-based approaches, remote sensing with object-based classification methods is reported to achieve improved classification results in complex heterogeneous landscapes. This study assessed the usefulness of object-oriented analysis of Quickbird high spatial resolution satellite data to classify urban and peri-urban agriculture in a limited peri-urban area of Hanoi, Vietnam. The results revealed that segmentation was essential in developing the object-oriented classification approach. Accurate segmentation of shape and size of an object enhanced classification with spectral, textural, morphological, and topological features. A qualitative, visual comparison of the classification results showed successful localisation and identification of most LCLU classes. Quantitative evaluation was conducted with a classification error matrix reaching an overall accuracy of 67% and a kappa coefficient of 0.61. In general, object-oriented classification of high spatial resolution satellite data proved the promising approach for LCLU analysis at village level. Capturing small-scale urban and peri-urban agricultural diversity offers a considerable potential for environmental monitoring. Challenges remain with the delineation of field boundaries and LCLU diversity on more spatially extensive datasets.

  17. High Resolution Spatial and Temporal Mapping of Traffic-Related Air Pollutants

    PubMed Central

    Batterman, Stuart; Ganguly, Rajiv; Harbin, Paul

    2015-01-01

    Vehicle traffic is one of the most significant emission sources of air pollutants in urban areas. While the influence of mobile source emissions is felt throughout an urban area, concentrations from mobile emissions can be highest near major roadways. At present, information regarding the spatial and temporal patterns and the share of pollution attributable to traffic-related air pollutants is limited, in part due to concentrations that fall sharply with distance from roadways, as well as the few monitoring sites available in cities. This study uses a newly developed dispersion model (RLINE) and a spatially and temporally resolved emissions inventory to predict hourly PM2.5 and NOx concentrations across Detroit (MI, USA) at very high spatial resolution. Results for annual averages and high pollution days show contrasting patterns, the need for spatially resolved analyses, and the limitations of surrogate metrics like proximity or distance to roads. Data requirements, computational and modeling issues are discussed. High resolution pollutant data enable the identification of pollutant “hotspots”, “project-level” analyses of transportation options, development of exposure measures for epidemiology studies, delineation of vulnerable and susceptible populations, policy analyses examining risks and benefits of mitigation options, and the development of sustainability indicators integrating environmental, social, economic and health information. PMID:25837345

  18. Assessing spatial resolution versus sensitivity from laser speckle contrast imaging: application to frequency analysis.

    PubMed

    Bricq, Stéphanie; Mahé, Guillaume; Rousseau, David; Humeau-Heurtier, Anne; Chapeau-Blondeau, François; Varela, Julio Rojas; Abraham, Pierre

    2012-10-01

    For blood perfusion monitoring, laser speckle contrast (LSC) imaging is a recent non-contact technique that has the characteristic of delivering noise-like speckled images. To exploit LSC images for quantitative physiological measurements, we developed an approach that implements controlled spatial averaging to reduce the detrimental impact of the noise and improve measurement sensitivity. By this approach, spatial resolution and measurement sensitivity can be traded-off in a flexible way depending on the quantitative prospect of the study. As an application, detectability of the cardiac activity from LSC images of forearm using power spectrum analysis is studied through the construction of spatial activity maps offering a window on the blood flow perfusion and its regional distribution. Comparisons with results obtained with signals of laser Doppler flowmetry probes are performed. PMID:22644256

  19. In vivo functional connectome of human brainstem nuclei of the ascending arousal, autonomic and motor systems by high spatial resolution 7 Tesla fMRI

    PubMed Central

    Bianciardi, Marta; Toschi, Nicola; Eichner, Cornelius; Polimeni, Jonathan R.; Setsompop, Kawin; Brown, Emery N.; Hamalainen, Matti S.; Rosen, Bruce R.; Wald, Lawrence L.

    2016-01-01

    Object To map the in vivo human functional connectivity of several brainstem nuclei with the rest of the brain by using seed-based correlation of ultra-high magnetic field functional magnetic resonance imaging (fMRI) data. Materials and Methods We used the recently developed template of 11 brainstem nuclei derived from multi-contrast structural MRI at 7 Tesla as seed regions to determine their connectivity to the rest of the brain. To achieve this, we utilized the increased contrast-to-noise ratio of 7 Tesla fMRI compared to 3 Tesla and the time efficient simultaneous multi-slice imaging to cover the brain with high spatial resolution (1.1 mm-isotropic nominal resolution) while maintaining a short repetition time (2.5 s). Results The delineated Pearson’s correlation-based functional connectivity diagrams (connectomes) of 11 brainstem nuclei of the ascending arousal, motor and autonomic systems from 12 controls are presented and discussed in the context of existing histology and animal work. Conclusion Considering that the investigated brainstem nuclei play a crucial role in several vital functions, the delineated preliminary connectomes might prove useful for future in vivo research and clinical studies of human brainstem function and pathology, including disorders of consciousness, sleep disorders, autonomic disorders, Parkinson’s disease and other motor disorders. PMID:27126248

  20. Effects of spatial resolution and noise on gamma analysis for IMRT QA

    PubMed Central

    Huang, Jessie Y.; Pulliam, Kiley B.; McKenzie, Elizabeth M.; Followill, David S.; Kry, Stephen F.

    2014-01-01

    We investigated the sensitivity of the gamma index to two factors: the spatial resolution and the noise level in the measured dose distribution. We also examined how the choice of reference distribution and analysis software affect the sensitivity of gamma analysis to these two factors for quality assurance (QA) of intensity-modulated radiation therapy (IMRT) treatment plans. For ten clinical IMRT plans, the dose delivered to a transverse dose plane was measured with EDR2 radiographic film. To evaluate the effects of spatial resolution, each irradiated film was digitized using three different resolutions (71, 142, and 285 dpi). To evaluate the effects of image noise, 1% and 2% local Gaussian noise was added to the film images. Gamma analysis was performed using 2%/2 mm and 3%/3 mm acceptance criteria and two commercial software packages, OmniPro I’mRT and DoseLab Pro. Dose comparisons were performed with the treatment planning system (TPS)-calculated dose as the reference, and then repeated with the film as the reference to evaluate how the choice of reference distribution affects the results of dose comparisons. When the TPS-calculated dose was designated as the reference distribution, the percentage of pixels with passing gamma values increased with both increasing resolution and noise. For 3%/3 mm acceptance criteria, increasing the film image resolution by a factor of two and by a factor of four caused a median increase of 0.9% and 2.6%, respectively, in the percentage of pixels passing. Increasing the noise level in the film image resulted in a median increase in percentage of pixels passing of 5.5% for 1% added local Gaussian noise and 5.8% for 2% added noise. In contrast, when the film was designated as the reference distribution, the percentage of pixels passing decreased with increased film noise, while increased resolution had no significant effect on passing rates. Furthermore, the sensitivity of gamma analysis to noise and resolution differed between

  1. Flexible hydrological modeling - Disaggregation from lumped catchment scale to higher spatial resolutions

    NASA Astrophysics Data System (ADS)

    Tran, Quoc Quan; Willems, Patrick; Pannemans, Bart; Blanckaert, Joris; Pereira, Fernando; Nossent, Jiri; Cauwenberghs, Kris; Vansteenkiste, Thomas

    2015-04-01

    Based on an international literature review on model structures of existing rainfall-runoff and hydrological models, a generalized model structure is proposed. It consists of different types of meteorological components, storage components, splitting components and routing components. They can be spatially organized in a lumped way, or on a grid, spatially interlinked by source-to-sink or grid-to-grid (cell-to-cell) routing. The grid size of the model can be chosen depending on the application. The user can select/change the spatial resolution depending on the needs and/or the evaluation of the accuracy of the model results, or use different spatial resolutions in parallel for different applications. Major research questions addressed during the study are: How can we assure consistent results of the model at any spatial detail? How can we avoid strong or sudden changes in model parameters and corresponding simulation results, when one moves from one level of spatial detail to another? How can we limit the problem of overparameterization/equifinality when we move from the lumped model to the spatially distributed model? The proposed approach is a step-wise one, where first the lumped conceptual model is calibrated using a systematic, data-based approach, followed by a disaggregation step where the lumped parameters are disaggregated based on spatial catchment characteristics (topography, land use, soil characteristics). In this way, disaggregation can be done down to any spatial scale, and consistently among scales. Only few additional calibration parameters are introduced to scale the absolute spatial differences in model parameters, but keeping the relative differences as obtained from the spatial catchment characteristics. After calibration of the spatial model, the accuracies of the lumped and spatial models were compared for peak, low and cumulative runoff total and sub-flows (at downstream and internal gauging stations). For the distributed models, additional

  2. Objective Delineation of River Bed Surface Patches from High-Resolution Spatial Grain Size Data

    NASA Astrophysics Data System (ADS)

    Nelson, P. A.; Bellugi, D.; Dietrich, W. E.

    2010-12-01

    Gravel-bed rivers commonly display distinct sorting patterns on their beds. Visually, this heterogeneity often appears to form an organization of distinct textural patches or facies. The local bed surface grain size, and therefore bed surface patchiness, exerts considerable influence on local bed mobility, bedload transport rates, hydrodynamic roughness, and benthic microhabitats. Despite the ecological and morphodynamic importance of bed surface patchiness, we lack accurate and objective methods to delineate bed patches. However, recent advances in photographic measurement of bed surface grain size distributions are capable of providing data at a spatial resolution high enough to allow us an opportunity to answer the question: what is a patch? Here, we explore a variety of techniques that can be applied to high-resolution spatial grain size data to automatically generate maps of grain size patches. We apply a state-of-the-art image processing and machine learning procedure to a photographic survey of the bed surface of a near-field scale flume to extract grain size data and to generate a spatial grid of bed surface grain size distributions. The flume bed was composed of gravel 2-45 mm in diameter and it featured clearly identifiable sorting features. Using this dataset, we investigate several possible methods of patch delineation. The grid of grain size distributions can be represented by a graph of nodes (grain size distributions) connected by edges whose weight is a function of the similarity between two nodes. Spectral graph theory is then used to optimally cut the edges in order to produce a spatial structure of patches that minimizes the association between patches and maximizes the association of nodes within a patch. In a different approach, agglomerative clustering of spatially adjacent grain size distributions is used to produce a hierarchical dendrogram that can be thresholded to partition the bed into patches. We also explore using the k-means algorithm

  3. Increasing spatial resolution of CHIRPS rainfall datasets for Cyprus with artificial neural networks

    NASA Astrophysics Data System (ADS)

    Tymvios, Filippos; Michaelides, Silas; Retalis, Adrianos; Katsanos, Dimitrios; Lelieveld, Jos

    2016-08-01

    The use of high resolution rainfall datasets is an alternative way of studying climatological regions where conventional rain measurements are sparse or not available. Starting in 1981 to near-present, the CHIRPS (Climate Hazards Group InfraRed Precipitation with Station data) dataset incorporates a 5km×5km resolution satellite imagery with in-situ station data to create gridded rainfall time series for trend analysis, severe events and seasonal drought monitoring. The aim of this work is to further increase the resolution of the rainfall dataset for Cyprus to 1km×1km, by correlating the CHIRPS dataset with elevation information, the NDVI index (Normalized Difference Vegetation Index) from satellite images at 1km×1km and precipitation measurements from the official raingauge network of the Cyprus' Department of Meteorology, utilizing Artificial Neural Networks. The Artificial Neural Networks' architecture that was implemented is the Multi-Layer Perceptron (MLP) trained with the back propagation method, which is widely used in environmental studies. Seven different network architectures were tested, all with two hidden layers. The number of neurons ranged from 3 to10 in the first hidden layer and from 5 to 25 in the second hidden layer. The dataset was separated into a randomly selected training set, a validation set and a testing set; the latter is independently used for the final assessment of the models' performance. Using the Artificial Neural Network approach, a new map of the spatial analysis of rainfall is constructed which exhibits a considerable increase in its spatial resolution. A statistical assessment of the new spatial analysis was made using the rainfall ground measurements from the raingauge network. The assessment indicates that the methodology is promising for several applications.

  4. The optomotor response and spatial resolution of the visual system in male Xenos vesparum (Strepsiptera).

    PubMed

    Pix, W; Zanker, J M; Zeil, J

    2000-11-01

    The Strepsiptera are an enigmatic group of parasitic insects whose phylogenetic relationships are hotly debated. Male Strepsiptera have very unusual compound eyes, in which each of a small number of ommatidia possesses a retina of at least 60 retinula cells. We analysed the optomotor response of Xenos vesparum males to determine whether spatial resolution in these eyes is limited by the interommatidial angle or by the higher resolution potentially provided by the extended array of retinula cells within each ommatidium. We find that the optomotor response in Strepsiptera has a typical bandpass characteristic in the temporal domain, with a temporal frequency optimum at 1-3 Hz. As a function of spatial wavelength, the optomotor response is zero at grating periods below 12 degrees and reaches its maximum strength at grating periods between 60 degrees and 70 degrees. To identify the combination of interommatidial angles and angular sensitivity functions that would generate such a spatial characteristic, we used motion detection theory to model the spatial tuning function of the strepsipteran optomotor response. We found the best correspondence between the measured response profile and theoretical prediction for an irregular array of sampling distances spaced around 9 degrees (half the estimated interommatidial angle) and an angular sensitivity function of approximately 50 degrees, which corresponds to the angular extent of the retina we estimated at the centre of curvature of the lens. Our behavioural data strongly suggest that, at least for the optomotor response, the resolution of the strepsipteran compound eye is limited by the ommatidial sampling array and not by the array of retinula cells within each ommatidium. We discuss the significance of these results in relation to the functional organisation of strepsipteran compound eyes, their evolution and the role of vision in these insects. PMID:11044379

  5. Spatial resolution dependence on spectral frequency in human speech cortex electrocorticography

    NASA Astrophysics Data System (ADS)

    Muller, Leah; Hamilton, Liberty S.; Edwards, Erik; Bouchard, Kristofer E.; Chang, Edward F.

    2016-10-01

    Objective. Electrocorticography (ECoG) has become an important tool in human neuroscience and has tremendous potential for emerging applications in neural interface technology. Electrode array design parameters are outstanding issues for both research and clinical applications, and these parameters depend critically on the nature of the neural signals to be recorded. Here, we investigate the functional spatial resolution of neural signals recorded at the human cortical surface. We empirically derive spatial spread functions to quantify the shared neural activity for each frequency band of the electrocorticogram. Approach. Five subjects with high-density (4 mm center-to-center spacing) ECoG grid implants participated in speech perception and production tasks while neural activity was recorded from the speech cortex, including superior temporal gyrus, precentral gyrus, and postcentral gyrus. The cortical surface field potential was decomposed into traditional EEG frequency bands. Signal similarity between electrode pairs for each frequency band was quantified using a Pearson correlation coefficient. Main results. The correlation of neural activity between electrode pairs was inversely related to the distance between the electrodes; this relationship was used to quantify spatial falloff functions for cortical subdomains. As expected, lower frequencies remained correlated over larger distances than higher frequencies. However, both the envelope and phase of gamma and high gamma frequencies (30-150 Hz) are largely uncorrelated (<90%) at 4 mm, the smallest spacing of the high-density arrays. Thus, ECoG arrays smaller than 4 mm have significant promise for increasing signal resolution at high frequencies, whereas less additional gain is achieved for lower frequencies. Significance. Our findings quantitatively demonstrate the dependence of ECoG spatial resolution on the neural frequency of interest. We demonstrate that this relationship is consistent across patients and

  6. In-duct identification of fluid-borne source with high spatial resolution

    NASA Astrophysics Data System (ADS)

    Heo, Yong-Ho; Ih, Jeong-Guon; Bodén, Hans

    2014-11-01

    Source identification of acoustic characteristics of in-duct fluid machinery is required for coping with the fluid-borne noise. By knowing the acoustic pressure and particle velocity field at the source plane in detail, the sound generation mechanism of a fluid machine can be understood. The identified spatial distribution of the strength of major radiators would be useful for the low noise design. Conventional methods for measuring the source in a wide duct have not been very helpful in investigating the source properties in detail because their spatial resolution is improper for the design purpose. In this work, an inverse method to estimate the source parameters with a high spatial resolution is studied. The theoretical formulation including the evanescent modes and near-field measurement data is given for a wide duct. After validating the proposed method to a duct excited by an acoustic driver, an experiment on a duct system driven by an air blower is conducted in the presence of flow. A convergence test for the evanescent modes is performed to find the necessary number of modes to regenerate the measured pressure field precisely. By using the converged modal amplitudes, very-close near-field pressure to the source is regenerated and compared with the measured pressure, and the maximum error was -16.3 dB. The source parameters are restored from the converged modal amplitudes. Then, the distribution of source parameters on the driver and the blower is clearly revealed with a high spatial resolution for kR<1.84 in which range only plane waves can propagate to far field in a duct. Measurement using a flush mounted sensor array is discussed, and the removal of pure radial modes in the modeling is suggested.

  7. SXDF-ALMA 2-arcmin2 deep survey: 1.1-mm number counts

    NASA Astrophysics Data System (ADS)

    Hatsukade, Bunyo; Kohno, Kotaro; Umehata, Hideki; Aretxaga, Itziar; Caputi, Karina I.; Dunlop, James S.; Ikarashi, Soh; Iono, Daisuke; Ivison, Rob J.; Lee, Minju; Makiya, Ryu; Matsuda, Yuichi; Motohara, Kentaro; Nakanishi, Kouichiro; Ohta, Kouji; Tadaki, Ken-ich; Tamura, Yoichi; Wang, Wei-Hao; Wilson, Grant W.; Yamaguchi, Yuki; Yun, Min S.

    2016-06-01

    We report 1.1-mm number counts revealed with the Atacama Large Millimeter/submillimeter Array (ALMA) in the Subaru/XMM-Newton Deep Survey Field (SXDF). The advent of ALMA enables us to reveal millimeter-wavelength number counts down to the faint end without source confusion. However, previous studies are based on the ensemble of serendipitously detected sources in fields originally targeting different sources and could be biased due to the clustering of sources around the targets. We derive number counts in the flux range of 0.2-2 mJy by using 23 (≥4σ) sources detected in a continuous 2.0-arcmin2 area of the SXDF. The number counts are consistent with previous results within errors, suggesting that the counts derived from serendipitously detected sources are not significantly biased, although there could be field-to-field variation due to the small survey area. By using the best-fitting function of the number counts, we find that ˜40% of the extragalactic background light at 1.1 mm is resolved at S1.1mm > 0.2 mJy.

  8. HIGH SPATIAL RESOLUTION IMAGING OF INERTIAL FUSION TARGET PLASMAS USING BUBBLE NEWTRON DETECTORS

    SciTech Connect

    FISHER,RK

    2002-10-01

    OAK B202 HIGH SPATIAL RESOLUTION IMAGING OF INERTIAL FUSION TARGET PLASMAS USING BUBBLE NEWTRON DETECTORS. Bubble detectors, which can detect neutrons with a spatial resolution of 5 to 30 {micro}, are a promising approach to high-resolution imaging of NIF target plasmas. Gel bubble detectors were used in successful proof-of-principle imaging experiments on OMEGA. Until recently, bubble detectors appeared to be the only approach capable of achieving neutron images of NIF targets with the desired 5 {micro} spatial resolution in the target plane. In 2001, NIF reduced the required standoff distance from the target, so that diagnostic components can now be placed as close as 10 cm to the target plasma. This will allow neutron imaging with higher magnification and may make it possible to obtain 5 {micro}m resolution images on NIF using deuterated scintillators. Having accomplished all that they can hope to on OMEGA using gel detectors, they suggested that the 2002 NLUF shots be used to allow experimental tests of the spatial resolution of the CEA-built deuterated scintillators. The preliminary CEA data from the June 2002 run appears to show the spatial resolution using the deuterated scintillator detector array is improved over that obtained in earlier experiments using the proton-based scintillators. Gel detectors, which consist of {approx} 10 {micro}m diameter drops of bubble detector liquid suspended in an inactive support gel that occupies {approx} 99% of the detector volume, were chosen for the initial tests on OMEGA since they are easy to use. The bubbles could be photographed several hours after the neutron exposure. Imaging NIF target plasmas at neutron yields of 10{sup 15} will require a higher detection efficiency detector. Using a liquid bubble chamber detector should result in {approx} 1000 times higher neutron detection efficiency which is comparable to that possible using scintillation detectors. A pressure-cycled liquid bubble detector will require a light

  9. Nanoscale Spatial Organization of Prokaryotic Cells Studied by Super-Resolution Optical Microscopy

    NASA Astrophysics Data System (ADS)

    McEvoy, Andrea Lynn

    All cells spatially organize their interiors, and this arrangement is necessary for cell viability. Until recently, it was believed that only eukaryotic cells spatially segregate their components. However, it is becoming increasingly clear that bacteria also assemble their proteins into complex patterns. In eukaryotic cells, spatial organization arises from membrane bound organelles as well as motor transport proteins which can move cargos within the cell. To date, there are no known motor transport proteins in bacteria and most microbes lack membrane bound organelles, so it remains a mystery how bacterial spatial organization emerges. In hind-sight it is not surprising that bacteria also exhibit complex spatial organization considering much of what we have learned about the basic processes that take place in all cells, such as transcription and translation was first discovered in prokaryotic cells. Perhaps the fundamental principles that govern spatial organization in prokaryotic cells may be applicable in eukaryotic cells as well. In addition, bacteria are attractive model organism for spatial organization studies because they are genetically tractable, grow quickly and much biochemical and structural data is known about them. A powerful tool for observing spatial organization in cells is the fluorescence microscope. By specifically tagging a protein of interest with a fluorescent probe, it is possible to examine how proteins organize and dynamically assemble inside cells. A significant disadvantage of this technology is its spatial resolution (approximately 250 nm laterally and 500 nm axially). This limitation on resolution causes closely spaced proteins to look blurred making it difficult to observe the fine structure within the complexes. This resolution limit is especially problematic within small cells such as bacteria. With the recent invention of new optical microscopies, we now can surpass the existing limits of fluorescence imaging. In some cases, we can

  10. Effects of spatial resolution and spectral purity on transvenous coronary angiography images

    SciTech Connect

    Chapman, D.; Thomlinson, W.; Gumer, N.F.

    1994-11-01

    Measurements have been made on the National Synchrotron Light Source (NSLS) Coronary Angiography X17B2 beamline under ideal and real imaging conditions to investigate the optimal imaging conditions for spatial resolution and spectral purity. The spatial resolution tests were performed using two multielement Si(Li) detectors (600 element, 0.5mm, pixel-pixel spacing; 1200 element, 0.25mm pixel-pixel spacing. Images were taken of phantoms containing iodine contrast agent over a wide range of incident beam absorption conditions. Patient images were also obtained using the same viewing projection with both detectors. Harmonics present in the imaging beam can be reduced by operating the superconducting wiggler source at reduced field strength. At regions of high absorption in the patient, the harmonics present can contribute to the detected signal. Iodine phantom images were obtained at a wiggler field strength of 3 Tesla (E{sub c}=13.3keV) and 4 Tesla (E{sub c}= I 7.8keV) for comparison. As before, patient images were obtained using the same projection at both wiggler fields. Results of the detector resolution and wiggler eld measurements will be presented for the phantoms as well as the patient scans.

  11. Development of a US Carbon Dioxide Emission Inventory with High Spatial and Temporal Resolution

    NASA Astrophysics Data System (ADS)

    Frost, G. J.; Petron, G.; McKeen, S.; Capps, S.; Trainer, M.

    2006-12-01

    Power generation and transportation are responsible for about 40 percent and 33 percent, respectively, of the CO2 generated from US fossil fuel combustion. We are developing a US CO2 emission inventory of the power generation and on-road motor vehicle sectors that incorporates the high spatial and temporal resolution available in a variety of data sets. CO2 emission data with up to hourly resolution are measured by continuous emission monitors installed at most US power generation facilities. CO2 emissions from on-road motor vehicles are determined from annual Federal Highway Administration statistics on gasoline and diesel sales in every US state. These statewide data are spatially allocated to 4-km resolution using the EPA's National Emission Inventory estimates of NOx and CO emissions from on-road gasoline and diesel combustion. The inventory incorporating these highly resolved components is compared with other available bottom-up estimates of CO2 sources for the US. Comparisons are also made between this inventory and atmospheric measurements from air quality field studies during the past decade.

  12. A Compact "Water Window" Microscope with 60 nm Spatial Resolution for Applications in Biology and Nanotechnology.

    PubMed

    Wachulak, Przemyslaw; Torrisi, Alfio; Nawaz, Muhammad F; Bartnik, Andrzej; Adjei, Daniel; Vondrová, Šárka; Turňová, Jana; Jančarek, Alexandr; Limpouch, Jiří; Vrbová, Miroslava; Fiedorowicz, Henryk

    2015-10-01

    Short illumination wavelength allows an extension of the diffraction limit toward nanometer scale; thus, improving spatial resolution in optical systems. Soft X-ray (SXR) radiation, from "water window" spectral range, λ=2.3-4.4 nm wavelength, which is particularly suitable for biological imaging due to natural optical contrast provides better spatial resolution than one obtained with visible light microscopes. The high contrast in the "water window" is obtained because of selective radiation absorption by carbon and water, which are constituents of the biological samples. The development of SXR microscopes permits the visualization of features on the nanometer scale, but often with a tradeoff, which can be seen between the exposure time and the size and complexity of the microscopes. Thus, herein, we present a desk-top system, which overcomes the already mentioned limitations and is capable of resolving 60 nm features with very short exposure time. Even though the system is in its initial stage of development, we present different applications of the system for biology and nanotechnology. Construction of the microscope with recently acquired images of various samples will be presented and discussed. Such a high resolution imaging system represents an interesting solution for biomedical, material science, and nanotechnology applications.

  13. High-resolution wind profiling using combined spatial and frequency domain interferometry

    NASA Astrophysics Data System (ADS)

    Palmer, R. D.; Huang, X.; Fukao, S.; Yamamoto, M.; Nakamura, T.

    1995-11-01

    A novel approach to wind profiling is presented which is based on the hybrid use of spatial interferometry (SI) and frequency domain interferometry (FDI). Many algorithms exist that can be used to determine the wind field using SI. However, the imaging Doppler interferometry (IDI) technique is somewhat unique in that the wind field within the radar beam is angularly "imaged" using the Doppler sorting effect. The spatial locations of scatterers are determined by assuming a wind field across the beam and Fourier analyzing signals to sort Doppler velocities. Pulsed radar systems are limited in range resolution by the length of the transmitted pulse, and wind estimates are obtained for a discrete set of altitudes determined by sampling the continuous stream of signals. Frequency domain interferometry (FDI) can be used to determine the radial location of scattering layers within the resolution volume. Thus the combined use of FDI and IDI can provide the radial and angular location of particular scattering points. Using the Doppler sorting idea, a new wind profiling technique is presented which uses FDI to increase the altitude resolution of wind estimates obtained from IDI. Experimental data that illustrate the implementation of the algorithm are presented from the Middle and Upper (MU) Atmosphere radar.

  14. Comparing spatial tuning curves, spectral ripple resolution, and speech perception in cochlear implant users

    PubMed Central

    Anderson, Elizabeth S.; Nelson, David A.; Kreft, Heather; Nelson, Peggy B.; Oxenham, Andrew J.

    2011-01-01

    Spectral ripple discrimination thresholds were measured in 15 cochlear-implant users with broadband (350–5600 Hz) and octave-band noise stimuli. The results were compared with spatial tuning curve (STC) bandwidths previously obtained from the same subjects. Spatial tuning curve bandwidths did not correlate significantly with broadband spectral ripple discrimination thresholds but did correlate significantly with ripple discrimination thresholds when the rippled noise was confined to an octave-wide passband, centered on the STC’s probe electrode frequency allocation. Ripple discrimination thresholds were also measured for octave-band stimuli in four contiguous octaves, with center frequencies from 500 Hz to 4000 Hz. Substantial variations in thresholds with center frequency were found in individuals, but no general trends of increasing or decreasing resolution from apex to base were observed in the pooled data. Neither ripple nor STC measures correlated consistently with speech measures in noise and quiet in the sample of subjects in this study. Overall, the results suggest that spectral ripple discrimination measures provide a reasonable measure of spectral resolution that correlates well with more direct, but more time-consuming, measures of spectral resolution, but that such measures do not always provide a clear and robust predictor of performance in speech perception tasks. PMID:21786905

  15. Explore spatial-temporal relations: transient super-resolution with PMD sensors

    NASA Astrophysics Data System (ADS)

    Han, Chaosheng; Lin, Xing; Lin, Jingyu; Yan, Chenggang; Dai, Qionghai

    2014-11-01

    Transient imaging provides a direct view of how light travel in the scene, which leads to exciting applications such as looking around corners. Low-budget transient imagers, adapted from Time-of-Fight (ToF) cameras, reduce the barrier of entry for performing research of this new imaging modality. However, the image quality is far from satisfactory due to the limited resolution of PMD sensors. In this paper, we improve the resolution of transient images by modulating the illumination. We capture the scene under three linearly independent lighting conditions, and derive a theoretical model for the relationship between the time-profile and the corresponding 3D details of each pixel. Our key idea is that the light flight time in each pixel patch is proportional to the cross product of the illuminating direction and the surface normal. First we capture and reconstruct transient images by Fourier analysis at multiple illumination locations, and then fuse the data of acquired low-spatial resolution images to calculate the surface normal. Afterwards, we use an optimization procedure to split the pixels and finally enhance the image quality. We show that we can not only reveal the fine structure of the object but may also uncover the reflectance properties of different materials. We hope the idea of utilizing spatial-temporal relations will give new insights to the research and applications of transient imaging.

  16. Ultrahigh-spatial-resolution chemical and magnetic imaging by laser-based photoemission electron microscopy

    SciTech Connect

    Taniuchi, Toshiyuki Kotani, Yoshinori; Shin, Shik

    2015-02-15

    We report the first experiments carried out on a new chemical and magnetic imaging system, which combines the high spatial resolution of a photoemission electron microscope (PEEM) with a continuous-wave deep-ultraviolet laser. Threshold photoemission is sensitive to the chemical and magnetic structures of the surface of materials. The spatial resolution of PEEM is limited by space charging when using pulsed photon sources as well as aberrations in the electron optics. We show that the use of a continuous-wave laser enabled us to overcome such a limit by suppressing the space-charge effect, allowing us to obtain a resolution of approximately 2.6 nm. With this system, we demonstrated the imaging of surface reconstruction domains on Si(001) by linear dichroism with normal incidence of the laser beam. We also succeeded in magnetic imaging of thin films with the use of magnetic circular dichroism near the Fermi level. The unique features of the ultraviolet laser will give us fast switching of the incident angles and polarizations of the photon source, which will be useful for the characterization of antiferromagnetic materials as well as ferromagnetic materials.

  17. Improving Spatial Resolution of Agricultural Water Use Estimation Using ALOS AVNIR-2 Imagery

    NASA Astrophysics Data System (ADS)

    Alexandridis, T. K.; Chemin, Y.; Cherif, I.; Tsakoumis, G.; Galanis, G.; Arampatzis, G.; Zalidis, G. C.; Silleos, N. G.; Stavrinos, E.

    2008-11-01

    Estimating agricultural water use is an issue of primary importance in the Mediterranean. At the same time, several advanced algorithms have been developed, which couple Earth Observation data in thermal, visible and near-infrared wavelengths with a few meteorological measurements to provide a close approximation to the actual water use. However, due to the detailed cropping pattern of the Greek agricultural landscape, higher resolution satellite imagery is necessary, a demand which may not be met by the available thermal infrared imagery (Landsat 5 TM and Terra/ASTER). This study investigates the contribution of ALOS AVNIR-2 images to estimate agricultural water consumption in high spatial resolution. Two methods were tested, the Surface Energy Balance Algorithm for Land and the remote sensing crop coefficient method. The results were compared against similar products derived with Terra/MODIS and Landsat TM images, used as reference. Comparisons were based on a pixel level, with a random dataset for pixel to pixel comparison and on a canal command area level, with statistical comparison of the water use estimations. Merging of the two datasets was based on the modified Brovey technique, which has the advantage of maintaining the original values, but redistributes them in a higher resolution space. Concluding, ALOS AVNIR-2 significantly underestimated agricultural water use with the crop coefficient method, but was successful in providing the element of high spatial detail to the MODIS derived result, proving to be a useful input in modelling water use of irrigated Greek basins.

  18. The influence of spectral and spatial resolution in classification approaches: Landsat TM data vs. Hyperspectral data

    NASA Astrophysics Data System (ADS)

    Rodríguez-Galiano, Víctor; Garcia-Soldado, Maria José; Chica-Olmo, Mario

    The importance of accurate and timely information describing the nature and extent of land and natural resources is increasing especially in rapidly growing metropolitan areas. While metropolitan area decision makers are in constant need of current geospatial information on patterns and trends in land cover and land use, relatively little researchers has investigated the influence of the satellite data resolution for monitoring geo-enviromental information. In this research a suite of remote sensing and GIS techniques is applied in a land use mapping study. The main task is to asses the influence of the spatial and spectral resolution in the separability between classes and in the classificatiońs accuracy. This study has been focused in a very dynamical area with respect to land use, located in the province of Granada (SE of Spain). The classifications results of the Airborne Hyperspectral Scanner (AHS, Daedalus Enterprise Inc., WA, EEUU) at different spatial resolutions: 2, 4 and 6 m and Landsat 5 TM data have been compared.

  19. The measurement of the presampled MTF of a high spatial resolution neutron imaging system

    NASA Astrophysics Data System (ADS)

    Cao, Raymond Lei.; Biegalski, Steven R.

    2007-11-01

    A high spatial resolution neutron imaging device was developed at the Mark II TRIGA reactor at The University of Texas at Austin. As the modulation transfer function (MTF) is recognized as a well-established parameter for evaluation of imaging system resolution, the aliasing associated with digital sampling adds complexity to its measurement. Aliasing is especially problematic when using a high spatial resolution micro-channel plate (MCP) neutron detector that has a pixel grid size similar to that of a CCD array. To compensate for the aliasing an angulated edge method was used to evaluate the neutron imaging facility, overcoming aliasing by obtaining an oversampled edge spread function (ESF). Baseline correction was applied to the ESF to remove the noticeable trends and the LSF was multiplied by Hann window to obtain a smoothed version of presampled MTF. The computing procedure is confirmed by visual inspection of a testing phantom; in addition, it is confirmed by comparison to the MTF measurement of a scintillation screen with a known MTF curve.

  20. Evaluation of ERTS-1 image sensor spatial resolution in photographic form

    NASA Technical Reports Server (NTRS)

    Slater, P. N. (Principal Investigator); Schowengerdt, R. A.

    1973-01-01

    The author has identified the following significant results. A coherent optical system was used to display the spatial frequency content of the amplitude image of one area of the ground as obtained in the four wavelength bands of the multispectral scanner. This enabled a rapid comparison to be made between the four bands, from which it was clear that bands 5 and 7 were preferred to the others in terms of image definition, and thus mapping and acreage estimation, for the particular agricultural area imaged. With suitable scaling it was also possible to compare the modulation, as a function of spatial frequency, of MSS bands 4 and 5 with the green (BB) and red (DD) bands of the same area from the Apollo 9, SO65 experiment. A significant result is that the modulation in the MSS amplitude imagery is 65%-90% of that in the Apollo 9 amplitude imagery. In addition, the ratio of spatial frequencies for the ERTS-1 and Apollo imagery, at which the same modulation occurs, lies between 0.55 and 0.75 for the red band. This ratio is closely related to the ratio of resolutions for the two sensors. These values corroborate statements that the resolution of the MSS imagery is better than anticipated by pre-flight predictions.

  1. High spatial and temporal resolution retrospective cine cardiovascular magnetic resonance from shortened free breathing real-time acquisitions

    PubMed Central

    2013-01-01

    Background Cine cardiovascular magnetic resonance (CMR) is challenging in patients who cannot perform repeated breath holds. Real-time, free-breathing acquisition is an alternative, but image quality is typically inferior. There is a clinical need for techniques that achieve similar image quality to the segmented cine using a free breathing acquisition. Previously, high quality retrospectively gated cine images have been reconstructed from real-time acquisitions using parallel imaging and motion correction. These methods had limited clinical applicability due to lengthy acquisitions and volumetric measurements obtained with such methods have not previously been evaluated systematically. Methods This study introduces a new retrospective reconstruction scheme for real-time cine imaging which aims to shorten the required acquisition. A real-time acquisition of 16-20s per acquired slice was inputted into a retrospective cine reconstruction algorithm, which employed non-rigid registration to remove respiratory motion and SPIRiT non-linear reconstruction with temporal regularization to fill in missing data. The algorithm was used to reconstruct cine loops with high spatial (1.3-1.8 × 1.8-2.1 mm2) and temporal resolution (retrospectively gated, 30 cardiac phases, temporal resolution 34.3 ± 9.1 ms). Validation was performed in 15 healthy volunteers using two different acquisition resolutions (256 × 144/192 × 128 matrix sizes). For each subject, 9 to 12 short axis and 3 long axis slices were imaged with both segmented and real-time acquisitions. The retrospectively reconstructed real-time cine images were compared to a traditional segmented breath-held acquisition in terms of image quality scores. Image quality scoring was performed by two experts using a scale between 1 and 5 (poor to good). For every subject, LAX and three SAX slices were selected and reviewed in the random order. The reviewers were blinded to the reconstruction approach and

  2. Mapping Mercury's Surface Composition at High Spatial Resolution with the MESSENGER X-Ray Spectrometer

    NASA Astrophysics Data System (ADS)

    Nittler, L. R.; Weider, S. Z.; Starr, R. D.; Vorburger, A.; Solomon, S. C.

    2014-12-01

    Previous global maps of Mg/Si and Al/Si and partial maps of S/Si, Ca/Si, and Fe/Si on Mercury's surface derived from orbital data acquired by the MESSENGER X-Ray Spectrometer (XRS) have been highly variable in resolution because of MESSENGER's eccentric orbit and high northern periapsis. The typical spatial resolution at northern latitudes in earlier maps was 200-500 km, a scale that allowed large geochemical terranes to be defined and chemical measurements to be made of features hundreds of kilometers in extent, but so far there have been very few analyses at smaller scales. MESSENGER is now orbiting at the lowest periapsis altitudes so far in the mission, and XRS measurements can thus be made at substantially improved resolution. For example, measurements with resolutions <100 km constituted 1% of the northern-hemisphere observations that were used to make the previous maps, but they make up 31% of those obtained in May and June of 2014. Preliminary analysis of these higher-resolution XRS data confirms the broad-scale geochemical features that have already been identified, but also reveals smaller-scale chemical heterogeneities. For instance, targeted XRS measurements indicate that the high-reflectance smooth plains deposit, about 125 km in extent, at the center of the Rachmaninoff basin has Mg/Si=0.6, higher than for other smooth plains deposits with similar reflectance characteristics (for which Mg/Si is typically <0.4), but similar to the darker material surrounding the unit. Although the high-resolution maps that we continue to generate have limited coverage, they reveal substantial chemical heterogeneity at the 100-km scale both within the northern volcanic plains and within the large high-Mg region that has been previously identified. In many cases, the chemical heterogeneity we observe is closely associated with spatial variations in spectral reflectance properties. Continued observations at ever lower altitudes will allow chemical mapping on Mercury at

  3. An Improved Multi-Temporal Insar Method for Increasing Spatial Resolution of Surface Deformation Measurements

    NASA Astrophysics Data System (ADS)

    Li, T.; Liu, G.; Jia, H.; Lin, H.; Zhang, R.; Yu, B.; Luo, Q.

    2013-10-01

    The multi-temporal interferometric synthetic aperture radar (InSAR) technology has proven very useful in extracting surface deformation with time series of SAR images over a study area. To increase spatial resolution of deformation information, this paper presents an improved multi-temporal InSAR (MTI) method by tracking both the point-like targets (PTs) and the distributed targets (DTs) with temporal steadiness of radar backscattering. The valid pixels corresponding to PTs and DTs are identified mainly by thresholding of the amplitude dispersion index (ADI) and the Pearson correlation coefficient (PCC). To efficiently reduce error propagation, a hierarchical analysis strategy is applied to extract deformation rates at the valid pixels. For the pixels with lower ADI values, the deformation rates are estimated on an optimized network by a least squared estimator and a region growing method. For the pixels with higher ADI values, they are classified into several groups by the ADI intervals, and the deformation rates are estimated through the multi-levels of processing. The nonlinear deformation values at all the valid pixels are estimated by spatiotemporally filtering and spatially integrating. The proposed MTI algorithm has been tested for subsidence detection over Tianjin in China using the 40 high resolution TerraSAR-X images acquired between 2009 and 2010, and validated by using the ground-based leveling measurements. The testing results indicate that the spatial resolution and coverage of subsidence data can be increased dramatically by the hierarchical analysis, and the accuracy in subsidence values derived from the MTI solution can reach up to a millimeter level.

  4. High-spatial resolution multispectral and panchromatic satellite imagery for mapping perennial desert plants

    NASA Astrophysics Data System (ADS)

    Alsharrah, Saad A.; Bruce, David A.; Bouabid, Rachid; Somenahalli, Sekhar; Corcoran, Paul A.

    2015-10-01

    The use of remote sensing techniques to extract vegetation cover information for the assessment and monitoring of land degradation in arid environments has gained increased interest in recent years. However, such a task can be challenging, especially for medium-spatial resolution satellite sensors, due to soil background effects and the distribution and structure of perennial desert vegetation. In this study, we utilised Pleiades high-spatial resolution, multispectral (2m) and panchromatic (0.5m) imagery and focused on mapping small shrubs and low-lying trees using three classification techniques: 1) vegetation indices (VI) threshold analysis, 2) pre-built object-oriented image analysis (OBIA), and 3) a developed vegetation shadow model (VSM). We evaluated the success of each approach using a root of the sum of the squares (RSS) metric, which incorporated field data as control and three error metrics relating to commission, omission, and percent cover. Results showed that optimum VI performers returned good vegetation cover estimates at certain thresholds, but failed to accurately map the distribution of the desert plants. Using the pre-built IMAGINE Objective OBIA approach, we improved the vegetation distribution mapping accuracy, but this came at the cost of over classification, similar to results of lowering VI thresholds. We further introduced the VSM which takes into account shadow for further refining vegetation cover classification derived from VI. The results showed significant improvements in vegetation cover and distribution accuracy compared to the other techniques. We argue that the VSM approach using high-spatial resolution imagery provides a more accurate representation of desert landscape vegetation and should be considered in assessments of desertification.

  5. Geometric-optics forest canopy modelling for high spatial resolution imagery

    SciTech Connect

    Fournier, R.A., Edwards, G.; Gauthier, R.P.

    1996-11-01

    This research studies processes influencing the radiometric appearance of a forest at fine spatial resolution. A canopy radiance model, Treatment of Radiance Emerging from Light Interactions in a Treed Environment (TRELITE), was formulated using a geometric-optical approach. This model explored the relationship between image radiometric textures and canopy physical parameters. TRELITE`s geometric parameters of influence were tree shape, pixel dimension, source and viewing directions, and forest configuration. TRELITE`s optical parameters and interaction processes were collimated and sky irradiance, surface reflectivity, object transmissivity, and projected and mutual shading. Simulated airborne images were generated from a physical representation of these parameters. Four conifer plantation test sites were chosen to evaluate the influence of the modelled parameters on the scene radiance. The Multispectral Electro-Optical Imaging Scanner (MEIS-II), with 45 cm spatial resolution for eight channels spanning visible to near-infrared, measured scene radiance. MEIS image radiance patterns were analyzed for single trees, in four monospecific stands. The influence on the simulated radiance of the modelled canopy factors in TRELITE were examined, on a single tree basis, to determine relative importance in high spatial resolution imagery. Several modelling options were tested. Among them, the most appropriate tree outline shape was the truncated ellipse. Details of simulated images, particularly those in shaded areas, compared more favorably with airborne images when both collimated and diffuse illumination were modelled. Three processes emerged which were imperative to successful simulation: mutual shading (on-object and between object), bidirectional reflectance, and light transmissivity through crowns. 9 refs., 2 figs., 2 tabs.

  6. Efficient one-pair experimental system for spatial resolution demonstration of prototype PET detectors.

    PubMed

    Tashima, Hideaki; Yoshida, Eiji; Hirano, Yoshiyuki; Nishikido, Fumihiko; Inadama, Naoko; Murayama, Hideo; Yamaya, Taiga

    2014-07-01

    In the development of depth-of-interaction (DOI)-positron emission tomography (PET) detectors, one of the important steps toward their practical use is an evaluation of their imaging performance, such as the spatial resolution as measured by use of a point source and a one-pair experimental system which simulates actual PET geometries. The DOI-PET detectors have a broad field of view providing good imaging performance compared with conventional detectors. Therefore, evaluation including the region from the center to the periphery close to the detector ring is required in an effort to show their advanced performance regarding uniform spatial resolution. In this study, we aimed to develop and evaluate an efficient one-pair experimental system for demonstration of the DOI-PET detector performance. For this purpose, we propose a one-pair experimental system that can simulate an arbitrary ring diameter and acquire projection data efficiently by skipping unnecessary combinations according to the position of the point source. As a result, the proposed system and our measuring scheme could significantly reduce the total measurement time, especially for a large ring size such as that used in brain PET scanners and whole-body PET scanners. We used the system to evaluate the X'tal cube PET detector with a 2-mm cubic crystal array arranged in simulated PET geometries with ring diameters of 8.2 and 14.6 cm for 12 and 18 detector blocks, respectively. The results showed that a uniform spatial resolution was achieved even in the peripheral region, and measurements were obtained semi-automatically in a short time. PMID:24938490

  7. THERMAL EFFECTS ON MASS AND SPATIAL RESOLUTION DURING LASER PULSE ATOM PROBE TOMOGRAPHY OF CERIUM OXIDE

    SciTech Connect

    Rita Kirchhofer; Melissa C. Teague; Brian P. Gorman

    2013-05-01

    Cerium oxide (CeO2) is an ideal surrogate material for trans-uranic elements and fission products found in nuclear fuels due to similarities in their thermal properties; therefore, cerium oxide was used to determine the best run condition for atom probe tomography (APT). Laser pulse APT is a technique that allows for spatial resolution in the nm scale and isotopic/elemental chemical identification. A systematic study of the impact of laser pulse energy and specimen base temperature on the mass resolution, measurement of stoichiometry, multiples, and evaporation mechanisms are reported in this paper. It was demonstrated that using laser pulse APT stoichiometric field evaporation of cerium oxide was achieved at 1 pJ laser pulse energy and 20 K specimen base temperature.

  8. Pushing the boundaries of spatial resolution in dosimetry using polymer gels and radiochromic films

    NASA Astrophysics Data System (ADS)

    Heilemann, G.; Georg, D.; Berg, A.

    2015-01-01

    Advanced radiotherapy and brachytherapy techniques are raising the bar for detectors with respect to high spatial resolution. Dosimetry based on most point-like dosimeters, e.g. diamond detectors or small volume ionization chambers cannot be used efficiently and accurately for detecting 2 or 3D-dose variations at millimeter scale. Hence radiochromic films and polymer gels with high two/three-dimensional resolution provide a good verification tool for measuring dose distributions of very small collimated beams. In this study the performance of film and gel detectors in detecting the very fine dose distributions generated from collimation holes of four different sizes is investigated. Pencil beams with diameters down to 0.455 mm could be resolved by both detector types comparably.

  9. Improving spatial resolution of convergent beam electron diffraction strain mapping in silicon microstructures

    SciTech Connect

    Armigliato, A.; Balboni, R.; Frabboni, S.

    2005-02-07

    Despite the use of nanometer-sized probes in field emission transmission electron microscopes, the spatial resolution in strain analysis performed by convergent beam electron diffraction is limited in one direction by the need for tilting the cross-sectional sample in the electron microscope off the vertical <110> direction. We demonstrate that it is possible to improve this resolution by using the <340> zone axis, instead of the <230> one, which has recently become of common use in the analysis of silicon microdevices. Quantitative strain information with good sensitivity and accuracy can be obtained in the new axis. An example of application to the two-dimensional strain mapping in shallow trench isolation structures, obtained with a scanning attachment and a high-angle annular dark-field detector, is reported.

  10. Terahertz near-field microscopy with subwavelength spatial resolution based on photoconductive antennas.

    PubMed

    Bitzer, Andreas; Ortner, Alex; Walther, Markus

    2010-07-01

    Imaging and sensing applications based on pulsed terahertz radiation have opened new possibilities for scientific and industrial applications. Many exploit the unique features of the terahertz (THz) spectral region, where common packaging materials are transparent and many chemical compounds show characteristic absorptions. Because of their diffraction limit, THz far-field imaging techniques lack microscopic resolution and, if subwavelength features have to be resolved, near-field techniques are required. Here, we present a THz near-field microscopy approach based on photoconductive antennas as the THz emitter and as a near-field probe. Our system allows us to measure amplitude, phase, and polarization of the electric fields in the vicinity of a sample with a spatial resolution on the micrometer scale (approximately lambda/20). Using a dielectric (plant leaf) and a metallic structure (microwire) as examples, we demonstrate the capabilities of our approach. PMID:20648112

  11. High-Resolution Cortical Dipole Imaging Using Spatial Inverse Filter Based on Filtering Property

    PubMed Central

    2016-01-01

    Cortical dipole imaging has been developed to visualize brain electrical activity in high spatial resolution. It is necessary to solve an inverse problem to estimate the cortical dipole distribution from the scalp potentials. In the present study, the accuracy of cortical dipole imaging was improved by focusing on filtering property of the spatial inverse filter. We proposed an inverse filter that optimizes filtering property using a sigmoid function. The ability of the proposed method was compared with the traditional inverse techniques, such as Tikhonov regularization, truncated singular value decomposition (TSVD), and truncated total least squares (TTLS), in a computer simulation. The proposed method was applied to human experimental data of visual evoked potentials. As a result, the estimation accuracy was improved and the localized dipole distribution was obtained with less noise. PMID:27688747

  12. High-Resolution Cortical Dipole Imaging Using Spatial Inverse Filter Based on Filtering Property

    PubMed Central

    2016-01-01

    Cortical dipole imaging has been developed to visualize brain electrical activity in high spatial resolution. It is necessary to solve an inverse problem to estimate the cortical dipole distribution from the scalp potentials. In the present study, the accuracy of cortical dipole imaging was improved by focusing on filtering property of the spatial inverse filter. We proposed an inverse filter that optimizes filtering property using a sigmoid function. The ability of the proposed method was compared with the traditional inverse techniques, such as Tikhonov regularization, truncated singular value decomposition (TSVD), and truncated total least squares (TTLS), in a computer simulation. The proposed method was applied to human experimental data of visual evoked potentials. As a result, the estimation accuracy was improved and the localized dipole distribution was obtained with less noise.

  13. High-Resolution Spatial Distribution and Estimation of Access to Improved Sanitation in Kenya

    PubMed Central

    Jia, Peng; Anderson, John D.; Leitner, Michael; Rheingans, Richard

    2016-01-01

    Background Access to sanitation facilities is imperative in reducing the risk of multiple adverse health outcomes. A distinct disparity in sanitation exists among different wealth levels in many low-income countries, which may hinder the progress across each of the Millennium Development Goals. Methods The surveyed households in 397 clusters from 2008–2009 Kenya Demographic and Health Surveys were divided into five wealth quintiles based on their national asset scores. A series of spatial analysis methods including excess risk, local spatial autocorrelation, and spatial interpolation were applied to observe disparities in coverage of improved sanitation among different wealth categories. The total number of the population with improved sanitation was estimated by interpolating, time-adjusting, and multiplying the surveyed coverage rates by high-resolution population grids. A comparison was then made with the annual estimates from United Nations Population Division and World Health Organization /United Nations Children's Fund Joint Monitoring Program for Water Supply and Sanitation. Results The Empirical Bayesian Kriging interpolation produced minimal root mean squared error for all clusters and five quintiles while predicting the raw and spatial coverage rates of improved sanitation. The coverage in southern regions was generally higher than in the north and east, and the coverage in the south decreased from Nairobi in all directions, while Nyanza and North Eastern Province had relatively poor coverage. The general clustering trend of high and low sanitation improvement among surveyed clusters was confirmed after spatial smoothing. Conclusions There exists an apparent disparity in sanitation among different wealth categories across Kenya and spatially smoothed coverage rates resulted in a closer estimation of the available statistics than raw coverage rates. Future intervention activities need to be tailored for both different wealth categories and nationally

  14. Investigation of spatial resolution and temporal performance of SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) with integrated electrostatic focusing

    NASA Astrophysics Data System (ADS)

    Scaduto, David A.; Lubinsky, Anthony R.; Rowlands, John A.; Kenmotsu, Hidenori; Nishimoto, Norihito; Nishino, Takeshi; Tanioka, Kenkichi; Zhao, Wei

    2014-03-01

    We have previously proposed SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout), a novel detector concept with potentially superior spatial resolution and low-dose performance compared with existing flat-panel imagers. The detector comprises a scintillator that is optically coupled to an amorphous selenium photoconductor operated with avalanche gain, known as high-gain avalanche rushing photoconductor (HARP). High resolution electron beam readout is achieved using a field emitter array (FEA). This combination of avalanche gain, allowing for very low-dose imaging, and electron emitter readout, providing high spatial resolution, offers potentially superior image quality compared with existing flat-panel imagers, with specific applications to fluoroscopy and breast imaging. Through the present collaboration, a prototype HARP sensor with integrated electrostatic focusing and nano- Spindt FEA readout technology has been fabricated. The integrated electron-optic focusing approach is more suitable for fabricating large-area detectors. We investigate the dependence of spatial resolution on sensor structure and operating conditions, and compare the performance of electrostatic focusing with previous technologies. Our results show a clear dependence of spatial resolution on electrostatic focusing potential, with performance approaching that of the previous design with external mesh-electrode. Further, temporal performance (lag) of the detector is evaluated and the results show that the integrated electrostatic focusing design exhibits comparable or better performance compared with the mesh-electrode design. This study represents the first technical evaluation and characterization of the SAPHIRE concept with integrated electrostatic focusing.

  15. A high spatial resolution Stokes polarimeter for motional Stark effect imaging.

    PubMed

    Thorman, Alex; Michael, Clive; Howard, John

    2013-06-01

    We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full Stokes vector of elliptically polarized and Doppler-shifted Stark-Zeeman Balmer-alpha emission from high energy neutral beams injected into the magnetized plasma. We describe the optical system and compare its performance against a Mueller matrix model that takes account of non-ideal performance of the switching ferro-electric liquid crystal waveplates and other polarizing components. PMID:23822345

  16. Implementation of a Gaussian beam laser and aspheric optics for high spatial resolution MALDI imaging MS.

    PubMed

    Zavalin, Andre; Yang, Junhai; Haase, Andreas; Holle, Armin; Caprioli, Richard

    2014-06-01

    We have investigated the use of a Gaussian beam laser for MALDI Imaging Mass Spectrometry to provide a precisely defined laser spot of 5 μm diameter on target using a commercial MALDI TOF instrument originally designed to produce a 20 μm diameter laser beam spot at its smallest setting. A Gaussian beam laser was installed in the instrument in combination with an aspheric focusing lens. This ion source produced sharp ion images at 5 μm spatial resolution with signals of high intensity as shown for images from thin tissue sections of mouse brain.

  17. Extraction Of Hydrological Parameters Using High Spatial Resolution Remote Sensing For KINEROS2 Model

    NASA Astrophysics Data System (ADS)

    Sadeh, Yuval; Blumberg, Dan G.; Cohen, Hai; Morin, Efrat; Maman, Shimrit

    2016-04-01

    Arid and semi-arid environments cover more than one-third of Earth's land surface; these environments are especially vulnerable to flash flood hazards due to the poor understanding of the phenomenon and the lack of meteorological, geomorphological, and hydrological data. For many years, catchment characteristics have been observed using point-based measurements such as rain gauges and soil sample analysis. Furthermore, flood modeling techniques are not always available in ungauged catchments or in regions where data are sparse. In comparison to point-based observations, using remote sensing technologies can provide continuous spatial hydrological parameters and variables. The advances in remote sensing technologies including weather radar-based quantitative precipitation estimation (QPE) and Earth observing satellites, provide new geo-spatial data using high spatial and temporal resolution for basin-scale geomorphological analysis and hydrological models. This study used high spatial resolution remote sensing to extract some of the main input parameters of Kinematic Runoff and Erosion Model (KINEROS2), for the arid medium size Rahaf watershed (76 km^2}), located in the Judean Desert, Israel. During the research a high resolution land cover map of Rahaf basin was created using WorldView-2 multispectral satellite imageries; surface roughness was estimated using SIR-C and COSMO-SkyMed Synthetic Aperture Radar (SAR) spaceborne sensors; and rainstorm characteristics were extracted from ground-based meteorological radar. Finally, all the remotely sensed extracted data were used as inputs for the KINEROS2 through Automated Geospatial Watershed Assessment (AGWA) tool. The model-simulated peak flow and volume were then compared to runoff measurements from the watershed's pouring point. This research demonstrates the ability of using remotely sensed extracted data as inputs for the KINEROS2 model. Using AGWA, each simulated storm was successfully calibrated, when the average

  18. Estimating and Mapping Urban Impervious Surfaces: Reflection on Spectral, Spatial, and Temporal Resolutions

    NASA Astrophysics Data System (ADS)

    Weng, Q.

    2007-12-01

    Impervious surface is a key indicator of urban environmental quality and urbanization degree. Therefore, estimation and mapping of impervious surfaces in urban areas has attracted more and more attention recently by using remote sensing digital images. In this paper, satellite images with various spectral, spatial, and temporal resolutions are employed to examine the effects of these remote sensing data characteristics on mapping accuracy of urban impervious surfaces. The study area was the city proper of Indianapolis (Marion County), Indiana, United States. Linear spectral mixture analysis was applied to generate high albedo, low albedo, vegetation, and soil fraction images (endmembers) from the satellite images, and impervious surfaces were then estimated by adding high albedo and low albedo fraction images. A comparison of EO-1 ALI (multispectral) and Hyperion (hyperspectral) images indicates that the Hyperion image was more effective in discerning low albedo surface materials, especially the spectral bands in the mid-infrared region. Linear spectral mixing modeling was found more useful for medium spatial resolution images, such as Landsat TM/ETM+ and ASTER images, due to the existence of a large amount of mixed pixels in the urban areas. The model, however, may not be suitable for high spatial resolution images, such as IKONOS images, because of less influence from the mixing pixel. The shadow problem in the high spatial resolution images, caused by tall buildings and large tree crowns, is a challenge in impervious surface extraction. Alternative image processing algorithms such as decision tree classifier may be more appropriate to achieve high mapping accuracy. For mid-latitude cities, seasonal vegetation phenology has a significant effect on the spectral response of terrestrial features, and therefore, image analysis must take into account of this environmental characteristic. Three ASTER images, acquired on April 5, 2004, June 16, 2001, and October 3, 2000

  19. Cumulus cloud base height estimation from high spatial resolution Landsat data - A Hough transform approach

    NASA Technical Reports Server (NTRS)

    Berendes, Todd; Sengupta, Sailes K.; Welch, Ron M.; Wielicki, Bruce A.; Navar, Murgesh

    1992-01-01

    A semiautomated methodology is developed for estimating cumulus cloud base heights on the basis of high spatial resolution Landsat MSS data, using various image-processing techniques to match cloud edges with their corresponding shadow edges. The cloud base height is then estimated by computing the separation distance between the corresponding generalized Hough transform reference points. The differences between the cloud base heights computed by these means and a manual verification technique are of the order of 100 m or less; accuracies of 50-70 m may soon be possible via EOS instruments.

  20. Matrix Recrystallization for MALDI-MS Imaging of Maize Lipids at High-Spatial Resolution

    NASA Astrophysics Data System (ADS)

    Dueñas, Maria Emilia; Carlucci, Laura; Lee, Young Jin

    2016-09-01

    Matrix recrystallization is optimized and applied to improve lipid ion signals in maize embryos and leaves. A systematic study was performed varying solvent and incubation time. During this study, unexpected side reactions were found when methanol was used as a recrystallization solvent, resulting in the formation of a methyl ester of phosphatidic acid. Using an optimum recrystallization condition with isopropanol, there is no apparent delocalization demonstrated with a transmission electron microscopy (TEM) pattern and maize leaf images obtained at 10 μm spatial resolution.

  1. Magnetic resonance microscopy of chemically fixed human embryos at high spatial resolution.

    PubMed

    Otake, Yosuke; Handa, Shinya; Kose, Katsumi; Shiota, Kohei; Yamada, Shigehito; Uwabe, Chigako

    2015-01-01

    We acquired magnetic resonance (MR) microscopic images of chemically fixed human embryos of Carnegie stages 16 to 22 with a large image matrix (256 × 256 × 512) using an MR microscope that we developed with a 9.4-tesla vertical wide-bore superconducting magnet and a dual-channel receiver system to extend the dynamic range of the MR signal. The images showed clear anatomical structures at spatial resolutions of (40 µm)(3) to (60 µm)(3). We concluded that the experimental technique we developed will aid construction of the next anatomical database of the collection of chemically fixed human embryos. PMID:25740236

  2. Matrix recrystallization for MALDI-MS imaging of maize lipids at high-spatial resolution

    DOE PAGES

    Duenas, Maria Emilia; Carlucci, Laura; Lee, Young Jin

    2016-06-27

    Matrix recrystallization is optimized and applied to improve lipid ion signals in maize embryos and leaves. A systematic study was performed varying solvent and incubation time. During this study, unexpected side reactions were found when methanol was used as a recrystallization solvent, resulting in the formation of a methyl ester of phosphatidic acid. Furthermore, using an optimum recrystallization condition with isopropanol, there is no apparent delocalization demonstrated with a transmission electron microscopy (TEM) pattern and maize leaf images obtained at 10 μm spatial resolution.

  3. The beauty of resolution: The SN Ib factory NGC 2770 spatially resolved

    NASA Astrophysics Data System (ADS)

    Thöne, C. C.; Christensen, L.; Gorosabel, J.; de Ugarte Postigo, A.

    2015-02-01

    The late-type spiral NGC 2770 hosted 3 Type Ib supernovae (SNe) in or next to star-forming regions in its outer spiral arms. We study the properties of the SN sites and the galaxy at different spatial resolutions to infer propeties of the SN progenitors and the SF history of the galaxy. Several 3D techniques are used and, for the first time, we present images of metallicity, shocks and stellar population ages from OSIRIS/GTC imaging with tunable narrowband filters.

  4. Radiometric Calibration Assessment of Commercial High Spatial Resolution Multispectral Image Products

    NASA Technical Reports Server (NTRS)

    Holekamp, Kara; Aaron, David; Thome, Kurtis

    2006-01-01

    Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can better understand their properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, satellite at-sensor radiance values were compared to those estimated by each independent team member to determine the sensor's radiometric accuracy. The combined results of this evaluation provide the user community with an independent assessment of these commercially available high spatial resolution sensors' absolute calibration values.

  5. Correct self-assembling of spatial frequencies in super-resolution synthetic aperture digital holography.

    PubMed

    Paturzo, Melania; Ferraro, Pietro

    2009-12-01

    Synthetic aperture enlargement is obtained, in lensless digital holography, by introducing a diffraction grating between the object and the CCD camera with the aim of getting super-resolution. We demonstrate here that the spatial frequencies are naturally self-assembled in the reconstructed image plane when the NA is increased synthetically at its maximum extent of three times. By this approach it possible to avoid the use of the grating transmission formula in the numerical reconstruction process, thus reducing significantly the noise in the final super-resolved image. Demonstrations are reported in 1D and 2D with an optical target and a biological sample, respectively.

  6. Matrix Recrystallization for MALDI-MS Imaging of Maize Lipids at High-Spatial Resolution.

    PubMed

    Dueñas, Maria Emilia; Carlucci, Laura; Lee, Young Jin

    2016-09-01

    Matrix recrystallization is optimized and applied to improve lipid ion signals in maize embryos and leaves. A systematic study was performed varying solvent and incubation time. During this study, unexpected side reactions were found when methanol was used as a recrystallization solvent, resulting in the formation of a methyl ester of phosphatidic acid. Using an optimum recrystallization condition with isopropanol, there is no apparent delocalization demonstrated with a transmission electron microscopy (TEM) pattern and maize leaf images obtained at 10 μm spatial resolution. Graphical Abstract ᅟ.

  7. A high spatial resolution Stokes polarimeter for motional Stark effect imaging

    SciTech Connect

    Thorman, Alex; Michael, Clive; Howard, John

    2013-06-15

    We describe an enhanced temporally switched interfero-polarimeter that has been successfully deployed for high spatial resolution motional Stark effect imaging on the KSTAR superconducting tokamak. The system utilizes dual switching ferroelectric liquid crystal waveplates to image the full Stokes vector of elliptically polarized and Doppler-shifted Stark-Zeeman Balmer-alpha emission from high energy neutral beams injected into the magnetized plasma. We describe the optical system and compare its performance against a Mueller matrix model that takes account of non-ideal performance of the switching ferro-electric liquid crystal waveplates and other polarizing components.

  8. Implementation of a Gaussian Beam Laser and Aspheric Optics for High Spatial Resolution MALDI Imaging MS

    NASA Astrophysics Data System (ADS)

    Zavalin, Andre; Yang, Junhai; Haase, Andreas; Holle, Armin; Caprioli, Richard

    2014-06-01

    We have investigated the use of a Gaussian beam laser for MALDI Imaging Mass Spectrometry to provide a precisely defined laser spot of 5 μm diameter on target using a commercial MALDI TOF instrument originally designed to produce a 20 μm diameter laser beam spot at its smallest setting. A Gaussian beam laser was installed in the instrument in combination with an aspheric focusing lens. This ion source produced sharp ion images at 5 μm spatial resolution with signals of high intensity as shown for images from thin tissue sections of mouse brain.

  9. HIGH-RESOLUTION SPATIAL MODELING OF DAILY WEATHER ELEMENTS FOR A CATCHMENT IN THE OREGON CASCADE MOUNTAINS, UNITED STATES

    EPA Science Inventory

    High-quality, daily meteorological data at high spatial resolution are essential for a variety of hydrologic and ecological modeling applications that support environmental risk assessments and decision making. This paper describes the development, application, and assessment of ...

  10. Geostatistics for high resolution geomorphometry: from spatial continuity to surface texture

    NASA Astrophysics Data System (ADS)

    Trevisani, Sebastiano

    2015-04-01

    This presentation introduces the use of geostatistics in the context of high-resolution geomorphometry. The application of geostatistics to geomorphometry permits a shift in perspective, moving our attention more toward spatial continuity description than toward the inference of a spatial continuity model. This change in perspective opens interesting directions in the application of geostatistical methods in geomorphometry. Geostatistical methodologies have been extensively applied and adapted in the context of remote sensing, leading to many interesting applications aimed at the analysis of the complex patterns characterizing imagery. Among these applications the analysis of image texture has to be mentioned. In fact, the analysis of image texture reverts to the analysis of surface texture when the analyzed image is a raster representation of a digital terrain model. The main idea is to use spatial-continuity indices as multiscale and directional descriptors of surface texture, including the important aspect related to surface roughness. In this context we introduce some examples regarding the application of geostatistics for image analysis and surface texture characterization. We also show as in presence of complex morphological settings there is the need to use alternative indices of spatial continuity, less sensitive to hotspots and to non-stationarity that often characterize surface morphology. This introduction is mainly dedicated to univariate geostatistics; however the same concepts could be exploited by means of multivariate as well as multipoint geostatistics.

  11. Multi-resolution analysis of high density spatial and temporal cloud inhomogeneity fields from HOPE campaign

    NASA Astrophysics Data System (ADS)

    Lakshmi Madhavan, Bomidi; Deneke, Hartwig; Macke, Andreas

    2015-04-01

    Clouds are the most complex structures in both spatial and temporal scales of the Earth's atmosphere that effect the downward surface reaching fluxes and thus contribute to large uncertainty in the global radiation budget. Within the framework of High Definition Clouds and Precipitation for advancing Climate Prediction (HD(CP)2) Observational Prototype Experiment (HOPE), a high density network of 99 pyranometer stations was set up around Jülich, Germany (~ 10 × 12 km2 area) during April to July 2013 to capture the small-scale variability in cloud induced radiation fields at the surface. In this study, we perform multi-resolution analysis of the downward solar irradiance variability at the surface from the pyranometer network to investigate the dependence of temporal and spatial averaging scales on the variance and spatial correlation for different cloud regimes. Preliminary results indicate that correlation is strongly scale-dependent where as the variance is dependent on the length of averaging period. Implications of our findings will be useful for quantifying the effect of spatial collocation while validating the satellite inferred solar irradiance estimates, and also to explore the link between cloud structure and radiation. We will present the details of our analysis and results.

  12. Recent advances in the determination of a high spatial resolution geopotential model using chronometric geodesy

    NASA Astrophysics Data System (ADS)

    Lion, Guillaume; Guerlin, Christine; Bize, Sébastien; Wolf, Peter; Delva, Pacôme; Panet, Isabelle

    2016-04-01

    Current methods to determine the geopotential are mainly based on indirect approaches using gravimetric, gradiometric and topographic data. Satellite missions (GRACE, GOCE) have contributed significantly to improve the knowledge of the Earth's gravity field with a spatial resolution of about 90 km, but it is not enough to access, for example, to the geoid variation in hilly regions. While airborne and ground-based gravimeters provide the high resolution, the problem of these technics is that the accuracy is hampered by the heterogeneous coverage of gravity data (ground and offshore). Recent technological advances in atomic clocks are opening new perspectives in the determination of the geopotential. To date, the best of them reach a stability of 1.6×10-18 (NIST, RIKEN + Univ. Tokyo) in just 7 hours of integration, an accuracy of 2.0×10-18 (JILA). Using the relation of the relativistic gravitational redshift, this corresponds to a determination of geopotential differences at the 0.1 m²/s² level (or 1 cm in geoid height). In this context, the present work aims at evaluating the contribution of optical atomic clocks for the determination of the geopotential at high spatial resolution. To do that, we have studied a test area surrounding the Massif Central in the middle of southern of France. This region, consists in low mountain ranges and plateaus, is interesting because, the gravitational field strength varies greatly from place to place at high resolution due to the relief. Here, we present the synthetic tests methodology: generation of synthetic gravity and potential data, then estimation of the potential from these data using the least-squares collocation and assessment of the clocks contribution. We shall see how the coverage of the data points (realistic or not) can affect the results, and discuss how to quantify the trade-off between the noise level and the number of data points used.

  13. COMPLEX ORGANIC MOLECULES AT HIGH SPATIAL RESOLUTION TOWARD ORION-KL. II. KINEMATICS

    SciTech Connect

    Friedel, D. N.; Widicus Weaver, S. L. E-mail: susanna.widicus.weaver@emory.edu

    2012-08-01

    It has recently been suggested that chemical processing can shape the spatial distributions of complex molecules in the Orion-KL region and leads to the nitrogen-oxygen 'chemical differentiation' seen in previous observations of this source. Orion-KL is a very dynamic region, and it is therefore also possible that physical conditions can shape the molecular distributions in this source. Only high spatial resolution observations can provide the information needed to disentangle these effects. Here, we present millimeter imaging studies of Orion-KL at various beam sizes using the Combined Array for Research in Millimeter-wave Astronomy. We compare molecular images with high spatial resolution images that trace the temperature, density, and kinematics of the source in order to investigate the effects of physical conditions on molecular distributions. These observations were conducted at {lambda} = 3 mm and included transitions of ethyl cyanide [C{sub 2}H{sub 5}CN], methyl formate [HCOOCH{sub 3}], formic acid [HCOOH], acetone [(CH{sub 3}){sub 2}CO], SiO, and methanol [CH{sub 3}OH]. We find differences in the molecular distributions as a function of each of the aforementioned physical factors. These results indicate that acetone may be produced by chemical processing and is robust to large changes in physical conditions, while formic acid is readily destroyed by gas-phase processing in warm and dense regions. We also find that while the spatial distributions of ethyl cyanide and methyl formate are not distinct as is suggested by the concept of 'chemical differentiation', local physical conditions shape the small-scale emission structure for these species.

  14. High Temporal and Spatial Resolution Coverage of Earth from Commercial AVSTAR Systems in Geostationary Orbit

    NASA Astrophysics Data System (ADS)

    Lecompte, M. A.; Heaps, J. F.; Williams, F. H.

    Imaging the earth from Geostationary Earth Orbit (GEO) allows frequent updates of environmental conditions within an observable hemisphere at time and spatial scales appropriate to the most transient observable terrestrial phenomena. Coverage provided by current GEO Meteorological Satellites (METSATS) fails to fully exploit this advantage due primarily to obsolescent technology and also institutional inertia. With the full benefit of GEO based imaging unrealized, rapidly evolving phenomena, occurring at the smallest spatial and temporal scales that frequently have significant environmental impact remain unobserved. These phenomena may be precursors for the most destructive natural processes that adversely effect society. Timely distribution of information derived from "real-time" observations thus may provide opportunities to mitigate much of the damage to life and property that would otherwise occur. AstroVision International's AVStar Earth monitoring system is designed to overcome the current limitations if GEO Earth coverage and to provide real time monitoring of changes to the Earth's complete atmospheric, land and marine surface environments including fires, volcanic events, lightning and meteoritic events on a "live," true color, and multispectral basis. The understanding of severe storm dynamics and its coupling to the earth's electro-sphere will be greatly enhanced by observations at unprecedented sampling frequencies and spatial resolution. Better understanding of these natural phenomena and AVStar operational real-time coverage may also benefit society through improvements in severe weather prediction and warning. AstroVision's AVStar system, designed to provide this capability with the first of a constellation of GEO- based commercial environmental monitoring satellites to be launched in late 2003 will be discussed, including spatial and temporal resolution, spectral coverage with applications and an inventory of the potential benefits to society

  15. Monitoring of Antarctic moss ecosystems using a high spatial resolution imaging spectroscopy

    NASA Astrophysics Data System (ADS)

    Malenovsky, Zbynek; Lucieer, Arko; Robinson, Sharon; Harwin, Stephen; Turner, Darren; Veness, Tony

    2013-04-01

    The most abundant photosynthetically active plants growing along the rocky Antarctic shore are mosses of three species: Schistidium antarctici, Ceratodon purpureus, and Bryum pseudotriquetrum. Even though mosses are well adapted to the extreme climate conditions, their existence in Antarctica depends strongly on availability of liquid water from snowmelt during the short summer season. Recent changes in temperature, wind speed and stratospheric ozone are stimulating faster evaporation, which in turn influences moss growing rate, health state and abundance. This makes them an ideal bio-indicator of the Antarctic climate change. Very short growing season, lasting only about three months, requires a time efficient, easily deployable and spatially resolved method for monitoring the Antarctic moss beds. Ground and/or low-altitude airborne imaging spectroscopy (called also hyperspectral remote sensing) offers a fast and spatially explicit approach to investigate an actual spatial extent and physiological state of moss turfs. A dataset of ground-based spectral images was acquired with a mini-Hyperspec imaging spectrometer (Headwall Inc., the USA) during the Antarctic summer 2012 in the surroundings of the Australian Antarctic station Casey (Windmill Islands). The collection of high spatial resolution spectral images, with pixels about 2 cm in size containing from 162 up to 324 narrow spectral bands of wavelengths between 399 and 998 nm, was accompanied with point moss reflectance measurements recorded with the ASD HandHeld-2 spectroradiometer (Analytical Spectral Devices Inc., the USA). The first spectral analysis indicates significant differences in red-edge and near-infrared reflectance of differently watered moss patches. Contrary to high plants, where the Normalized Difference Vegetation Index (NDVI) represents an estimate of green biomass, NDVI of mosses indicates mainly the actual water content. Similarly to high plants, reflectance of visible wavelengths is

  16. Use of UAS Remote Sensing Data (AggieAir) to Estimate Crop ET at High Spatial Resolution

    NASA Astrophysics Data System (ADS)

    ELarab, M.; Torres, A.; Nieto Solana, H.; Kustas, W. P.; Song, L.; Alfieri, J. G.; Prueger, J. H.; McKee, L.; Anderson, M. C.; Jensen, A.; McKee, M.; Alsina, M. M.

    2015-12-01

    Estimation of the spatial distribution of evapotranspiration (ET) based on remotely sensed imagery has become useful for managing water in irrigated agricultural at various spatial scales. Currently, data acquired by conventional satellites (Landsat, ASTER, etc.) lack the needed spatial resolution to capture variability of interest to support evapotranspiration estimates. In this study, an unmanned aerial system (UAS), called AggieAirTM, was used to acquire high-resolution imagery in the visual, near infrared (0.15m resolution) and thermal infrared spectra (0.6m resolution). AggieAir flew over two study sites in Utah and Central Valley of California. The imagery was used as input to a surface energy balance model based on the Mapping Evapotranspiration with Internalized Calibration (METRIC) modeling approach. The discussion will highlight the ET estimation methodologies and the implications of having high resolution ET maps.

  17. Impact of horizontal spatial resolution on the derivation of the source receptor relationship—an extra-tropical cyclone case

    NASA Astrophysics Data System (ADS)

    Lee, Jae-Bum; Lee, Tae-Young

    2004-11-01

    A numerical study has been made to evaluate the impact of horizontal resolution on the estimation of the source receptor (S R) relationship. Numerical experiments with four different horizontal grid sizes have been performed for an extra-tropical cyclonic episode in East Asia. CSU RAMS and YU-SADM (Yonsei University's sulfuric acid deposition model) have been used to simulate meteorological and pollutant fields, respectively.In this study, enhanced spatial resolution has improved the simulation of an extra-tropical cyclone, cold front and associated precipitation systems. As spatial resolution increases, the circulation associated with the cyclone and cold front becomes stronger, and the amount of frontal rainfall increases. This study has shown that enhancement of spatial resolution tends to increase self-contributions but decrease foreign contributions to the wet deposition associated with an extra-tropical cyclone. It has been found that increased precipitation for enhanced spatial resolution reduces the amount of transported pollutant but increases the wet deposition of locally emitted pollutants. The larger self-contribution for higher resolutions may also be partially due to the increased strength of resolved convection. The impact of enhancing spatial resolution on dry deposition is felt mostly over downstream regions where the centres of the lows and fronts pass. Contributions from upstream sources increase as cyclonic circulation becomes stronger with increasing spatial resolution. On the other hand, enhancing spatial resolution does not significantly affect the S R relationship for either dry or wet deposition in the other regions where the extra-tropical cyclone does not pass. This study indicates that improved simulation of a cold front does not significantly affect the S R relationship for wet deposition over the area of passage of the cold front. An additional discussion infers a S R relationship for the wet deposition associated with a typical extra

  18. Spatial Disaggregation of the 0.25-degree GLDAS Air Temperature Dataset to 30-arcsec Resolution

    NASA Astrophysics Data System (ADS)

    Ji, L.; Senay, G. B.; Verdin, J. P.; Velpuri, N. M.

    2015-12-01

    Air temperature is a key input variable in ecological and hydrological models for simulating the hydrological cycle and water budget. Several global reanalysis products have been developed at different organizations, which provide gridded air temperature datasets at resolutions ranging from 0.25º to 2.5º (or 27.8 - 278.3 km at the equator). However, gridded air temperature products at a high-resolution (≤1 km) are available only for limited areas of the world. To meet the needs for global eco-hydrological modeling, we aim to produce a continuous daily air temperature datasets at 1-km resolution for the global coverage. In this study, we developed a technique that spatially disaggregates the 0.25º Global Land Data Assimilation System (GLDAS) daily air temperature data to 30-arcsec (0.928 km at the equator) resolution by integrating the GLDAS data with the 30-arcsec WorldClim 1950 - 2000 monthly normal air temperature data. The method was tested using the GLDAS and Worldclim maximum and minimum air temperature datasets from 2002 and 2010 for the conterminous Unites States and Africa. The 30-arcsec disaggregated GLDAS (GLDASd) air temperature dataset retains the mean values of the original GLDAS data, while adding spatial variabilities inherited from the Worldclim data. A great improvement in GLDAS disaggregation is shown in mountain areas where complex terrain features have strong impact on temperature. We validated the disaggregation method by comparing the GLDASd product with daily meteorological observations archived by the Global Historical Climatology Network (GHCN) and the Global Surface Summary of the Day (GSOD) datasets. Additionally, the 30-arcsec TopoWX daily air temperature product was used to compare with the GLDASd data for the conterminous United States. The proposed data disaggregation method provides a convenient and efficient tool for generating a global high-resolution air temperature dataset, which will be beneficial to global eco

  19. Delineation of river bed-surface patches by clustering high-resolution spatial grain size data

    NASA Astrophysics Data System (ADS)

    Nelson, Peter A.; Bellugi, Dino; Dietrich, William E.

    2014-01-01

    The beds of gravel-bed rivers commonly display distinct sorting patterns, which at length scales of ~ 0.1 - 1 channel widths appear to form an organization of patches or facies. This paper explores alternatives to traditional visual facies mapping by investigating methods of patch delineation in which clustering analysis is applied to a high-resolution grid of spatial grain-size distributions (GSDs) collected during a flume experiment. Specifically, we examine four clustering techniques: 1) partitional clustering of grain-size distributions with the k-means algorithm (assigning each GSD to a type of patch based solely on its distribution characteristics), 2) spatially-constrained agglomerative clustering ("growing" patches by merging adjacent GSDs, thus generating a hierarchical structure of patchiness), 3) spectral clustering using Normalized Cuts (using the spatial distance between GSDs and the distribution characteristics to generate a matrix describing the similarity between all GSDs, and using the eigenvalues of this matrix to divide the bed into patches), and 4) fuzzy clustering with the fuzzy c-means algorithm (assigning each GSD a membership probability to every patch type). For each clustering method, we calculate metrics describing how well-separated cluster-average GSDs are and how patches are arranged in space. We use these metrics to compute optimal clustering parameters, to compare the clustering methods against each other, and to compare clustering results with patches mapped visually during the flume experiment.All clustering methods produced better-separated patch GSDs than the visually-delineated patches. Although they do not produce crisp cluster assignment, fuzzy algorithms provide useful information that can characterize the uncertainty of a location on the bed belonging to any particular type of patch, and they can be used to characterize zones of transition from one patch to another. The extent to which spatial information influences

  20. Design and study of a coplanar grid array CdZnTe detector for improved spatial resolution.

    PubMed

    Ma, Yuedong; Xiao, Shali; Yang, Guoqiang; Zhang, Liuqiang

    2014-12-01

    Coplanar grid (CPG) CdZnTe detectors have been used as gamma-ray spectrometers for years. Comparing with pixelated CdZnTe detectors, CPG CdZnTe detectors have either no or poor spatial resolution, which directly limits its use in imaging applications. To address the issue, a 2×2 CPG array CdZnTe detector with dimensions of 7×7×5mm(3) was fabricated. Each of the CPG pairs in the detector was moderately shrunk in size and precisely designed to improve the spatial resolution while maintaining good energy resolution, considering the charge loss at the surface between the strips of each CPG pairs. Preliminary measurements were demonstrated at an energy resolution of 2.7-3.9% for the four CPG pairs using 662keV gamma rays and with a spatial resolution of 3.3mm, which is the best spatial resolution ever achieved for CPG CdZnTe detectors. The results reveal that the CPG CdZnTe detector can also be applied to imaging applications at a substantially higher spatial resolution.

  1. High Spatial Resolution Soil Moisture with Passive Active Sensors Using a Change Detection Approach: Studies Using SMAPVEX12 Data

    NASA Astrophysics Data System (ADS)

    Fang, B.; Lakshmi, V.; Bindlish, R.; Jackson, T. J.

    2014-12-01

    Soil moisture is an important variable in many areas of geosciences. The passive microwave sensors have been providing soil moisture of various spatial resolutions and are available for all-weather conditions. However, restricted by the antenna diameter of microwave radiometer, the spatial resolution of passive microwave soil moisture product is at tens of kilometers and needs to be improved for many applications. The SMAP (Soil Moisture Active Passive) is set to be launched in late 2014 and will be the first mission to provide L-band radar/radiometer soil moisture retrievals at three resolutions. The SMAPVEX12 is a pre-launch field validation experiment for evaluating and testing the soil moisture retrievals acquired from SMAP satellite. Airborne data using PALS (Passive/Active L-band Sensor) at two along-track resolutions (650 m and 1590 m) and UAVSAR (Uninhabited Aerial Vehicle Synthetic Aperture Radar) at 5 m spatial resolution as well as in-situ measurements were collected during the campaign. The study will implement a Single Channel Algorithm (SCA) to retrieve soil moisture from high/low altitude PALS L-band radiometer observations, as well as produce downscaled soil moisture change by combining low spatial resolution soil moisture retrievals and high spatial resolution PALS L-band radar observations through a change-detection algorithm, which models the relationship between change in radar backscatter and the change in soil moisture.

  2. Matrix sublimation/recrystallization for imaging proteins by mass spectrometry at high spatial resolution.

    PubMed

    Yang, Junhai; Caprioli, Richard M

    2011-07-15

    We have employed matrix deposition by sublimation for protein image analysis on tissue sections using a hydration/recrystallization process that produces high-quality MALDI mass spectra and high-spatial-resolution ion images. We systematically investigated different washing protocols, the effect of tissue section thickness, the amount of sublimated matrix per unit area, and different recrystallization conditions. The results show that an organic solvent rinse followed by ethanol/water rinses substantially increased sensitivity for the detection of proteins. Both the thickness of the tissue section and the amount of sinapinic acid sublimated per unit area have optimal ranges for maximal protein signal intensity. Ion images of mouse and rat brain sections at 50, 20, and 10 μm spatial resolution are presented and are correlated with hematoxylin and eosin (H&E)-stained optical images. For targeted analysis, histology-directed imaging can be performed using this protocol where MS analysis and H&E staining are performed on the same section.

  3. Exact two-dimensional zonal wavefront reconstruction with high spatial resolution in lateral shearing interferometry

    NASA Astrophysics Data System (ADS)

    Dai, Fengzhao; Li, Jie; Wang, Xiangzhao; Bu, Yang

    2016-05-01

    A novel zonal method is proposed for exact discrete reconstruction of a two-dimensional wavefront with high spatial resolution for lateral shearing interferometry. Four difference wavefronts measured in the x and y shear directions are required. Each of the two shear directions is measured twice with different shear amounts. The shear amounts of the second measurements of the x and y directions are Sx+1 pixels and Sy+1 pixels, where Sx pixels and Sy pixels are the shear amounts of the first measurements in the x and y directions, respectively. The shear amount in each direction can be chosen freely, provided that it is below a maximum value determined by the pupil shape and the number of samples N in that direction; thus, the choices are not limited by the more stringent condition required by previous methods, namely, that the shear amounts must be divisors of N. This method can exactly reconstruct any wavefront at evaluation points up to an arbitrary constant if the data is noiseless, and high spatial resolution can be achieved even with large shear amounts. The method is applicable not only to square pupils, but also to general pupil shapes if a sufficient number of Gerchberg iterations are employed. In this study, the validity and capability of the method were confirmed by numerical experiments. In addition, the experiments demonstrated that the method is stable with respect to noise in the difference wavefronts.

  4. VIIRS plus CrIMSS TPW - continuing the record of high spatial resolution moisture determinations

    NASA Astrophysics Data System (ADS)

    Menzel, W. P.; Borbas, E. E.; Li, Z.; Dobor, L.

    2015-12-01

    Total column water vapor properties are being derived from merged VIIRS infrared measurements and CrIMSS (CrIS plus ATMS) water vapor soundings in an attempt to continue the depiction of global moisture at high spatial resolution started with MODIS. While MODIS has two channels within the 6.5-μm H2O band and four channels within the 15-μm CO2 band, VIIRS has no infrared (IR) absorption channels. However, the VIIRS IR windows at 8.6, 10.8 and 12 μm give some indication of low level moisture (which constitutes much of the total column amount) and CrIMSS provide complementary column moisture determinations . The VIIRS/CrIMSS algorithm follows the approach used for MODIS; a clear sky regression relationship is established between total precipitable water vapor (TPW) and VIIRS IR window brightness temperatures (BTs) and CrIMSS water vapor soundings calculated from a global training radiosonde based profile data set. A high spatial resolution surface emissivity database is used to help differentiate surface emission and atmospheric moisture absorption. CrIMSS is added in clear and partly cloudy regions to enhance the TPW depiction and to extend the coverage. This poster presents comparisons of MODIS, VIIRS-only, VIIRS-CrIMSS TPW determinations and validations against ground truth MWR and GPS.

  5. Study on mosaic method for new mode satellite images with high spatial resolution covering urban areas

    NASA Astrophysics Data System (ADS)

    Ran, Qiong; Wang, Zhiyong; Wen, Qiang; Li, Wei; Gao, Lianru

    2014-11-01

    New imaging mode has been brought up for collecting multiple scenes in one pass, as is implemented on World View-II. This greatly helps for acquiring high spatial resolution images that cover urban areas, and is to be adopted in the coming Chinese satellites. This paper is to discuss the mosaic characteristic and propose a mosaic line generation method by integrating correlation and the road information. The mosaic line is formed by linking the unique mosaic point on each line restricted within the road. We position the starting point by connectivity analysis of the road lines, and then locate the adjacent point along the road with connectivity analysis. A weighed vector, combining correlation and distance to centre of the road, is used to pick the best point. The points are located on the road unless it is unavoidable, for example, the road ends or the line touches edge of the image. This method provides instant mosaic line generation for urban areas with road information available in most cases. By resorting to the road, the mosaic line is more applicable since many problems for mosaic of high spatial resolution images are solved, for example, tilting of the buildings, the shadows, motions of the vehicles etc. Experiments have been done with WV-II images and gained favorable results.

  6. Spatial resolution, signal-to-noise and information capacity of linear imaging systems.

    PubMed

    Gureyev, Timur; Nesterets, Yakov; de Hoog, Frank

    2016-07-25

    A simple model for image formation in linear shift-invariant systems is considered, in which both the detected signal and the noise variance are varying slowly compared to the point-spread function of the system. It is shown that within the constraints of this model, the square of the signal-to-noise ratio is always proportional to the "volume" of the spatial resolution unit. In the case of Poisson statistics, the ratio of these two quantities divided by the incident density of the imaging particles (e.g. photons) represents a dimensionless invariant of the imaging system, which was previously termed the intrinsic imaging quality. The relationship of this invariant to the notion of information capacity of communication and imaging systems, which was previously considered by Shannon, Gabor and others, is investigated. The results are then applied to a simple generic model of quantitative imaging of weakly scattering objects, leading to an estimate of the upper limit for the amount of information about the sample that can be obtained in such experiments. It is shown that this limit depends only on the total number of imaging particles incident on the sample, the average scattering coefficient, the size of the sample and the number of spatial resolution units. PMID:27464167

  7. Large patch convolutional neural networks for the scene classification of high spatial resolution imagery

    NASA Astrophysics Data System (ADS)

    Zhong, Yanfei; Fei, Feng; Zhang, Liangpei

    2016-04-01

    The increase of the spatial resolution of remote-sensing sensors helps to capture the abundant details related to the semantics of surface objects. However, it is difficult for the popular object-oriented classification approaches to acquire higher level semantics from the high spatial resolution remote-sensing (HSR-RS) images, which is often referred to as the "semantic gap." Instead of designing sophisticated operators, convolutional neural networks (CNNs), a typical deep learning method, can automatically discover intrinsic feature descriptors from a large number of input images to bridge the semantic gap. Due to the small data volume of the available HSR-RS scene datasets, which is far away from that of the natural scene datasets, there have been few reports of CNN approaches for HSR-RS image scene classifications. We propose a practical CNN architecture for HSR-RS scene classification, named the large patch convolutional neural network (LPCNN). The large patch sampling is used to generate hundreds of possible scene patches for the feature learning, and a global average pooling layer is used to replace the fully connected network as the classifier, which can greatly reduce the total parameters. The experiments confirm that the proposed LPCNN can learn effective local features to form an effective representation for different land-use scenes, and can achieve a performance that is comparable to the state-of-the-art on public HSR-RS scene datasets.

  8. Magnetic soft X-ray microscopy at 10nm spatial resolution

    NASA Astrophysics Data System (ADS)

    Fischer, Peter; Chao, Weilun; Im, Mi-Young; Anderson, Erik

    2011-03-01

    Magnetic soft X-ray microscopy, which combines high spatial and temporal resolution with elemental specificity by utilizing the specific features of X-ray magnetic circular dichroism effects is a unique and powerful analytical technique to image fast spin dynamics of nanoscale magnetism. The spatial resolution is determined by Fresnel zone plate lenses used as diffractive optics. FZPs are fabricated by state-of-the-art lithography techniques and the challenge is to produce a dense, circular line pattern with a high aspect ratio to achieve high efficiency. Using an overlay technique [2-3], which requires high position accuracy of the e-beam writer, FZPs with 12nm outermost zone width could be fabricated. Implementing this optic at BL 6.1.2 at the ALS in Berkeley CA, we have demonstrated that a 10nm line and space test pattern can be clearly resolved. First magnetic images of a PtCo film with a pronounced perpendicular anisotropy will be presented. Further progress to below 10nm can be anticipated in the near future. This work was supported by the U.S. Department of Energy under Contract No. DE-AC02-05-CH11231.

  9. Flood monitoring in a semi-arid environment using spatially high resolution radar and optical data.

    PubMed

    Seiler, Ralf; Schmidt, Jana; Diallo, Ousmane; Csaplovics, Elmar

    2009-05-01

    The geographic term "Niger Inland Delta" stands for a vast plain of approximately 40,000 km(2), which is situated in the western Sahel (Republic of Mali). The Inland Delta is affected by yearly inundation through the variable water levels of the Niger-Bani river system. Due to a good availability of (surface) water, the ecosystem at the Niger Inland Delta serves as resting place stop-over for many migrating birds and other wildlife species as well as economic base for farmers and pastoral people. To foster the sustainable usage of its natural resources and to protect this natural heritage, the entire Niger Inland Delta became RAMSAR site in 2004. This paper aims to test to which extent texture analysis can improve the quality of flood monitoring in a semi-arid environment using spatially high resolution ASAR imaging mode data. We found the Gray Level Dependence Method (GLDM) was most suitable proceeding for our data. Several statistical parameters were calculated via co-occurrence matrices and were used to classify the images in different gradation of soil moisture classes. In a second step we used additional information from spatially high resolution optical data (ASTER) to improve the separability of open water areas from moisture/vegetated areas.

  10. Music-reading expertise alters visual spatial resolution for musical notation.

    PubMed

    Wong, Yetta Kwailing; Gauthier, Isabel

    2012-08-01

    Crowding occurs when the perception of a suprathreshold target is impaired by nearby distractors, reflecting a fundamental limitation on visual spatial resolution. It is likely that crowding limits music reading, as each musical note is crowded by adjacent notes and by the five-line staff, similar to word reading, in which letter recognition is reduced by crowding from adjacent letters. Here, we tested the hypothesis that, with extensive experience, music-reading experts have acquired visual skills such that they experience a smaller crowding effect, resulting in higher music-reading fluency. Experts experienced a smaller crowding effect than did novices, but only for musical stimuli, not for control stimuli (Landolt Cs). The magnitude of the crowding effect for musical stimuli could be predicted by individual fluency in music reading. Our results highlight the role of experience in crowding: Visual spatial resolution can be improved specifically for objects associated with perceptual expertise. Music-reading rates are likely limited by crowding, and our results are consistent with the idea that experience alleviates these limitations.

  11. Effects of decreasing resolution on spectral and spatial information content in an agricultural area. [Pottawatmie study site, Iowa and Nebraska

    NASA Technical Reports Server (NTRS)

    1983-01-01

    The effects of decreasing spatial resolution from 6 1/4 miles square to 50 miles square are described. The effects of increases in cell size is studied on; the mean and variance of spectral data; spatial trends; and vegetative index numbers. Information content changes on cadastral, vegetal, soil, water and physiographic information are summarized.

  12. Improving urban land use and land cover classification from high-spatial-resolution hyperspectral imagery using contextual information

    Technology Transfer Automated Retrieval System (TEKTRAN)

    In this paper, we propose approaches to improve the pixel-based support vector machine (SVM) classification for urban land use and land cover (LULC) mapping from airborne hyperspectral imagery with high spatial resolution. Class spatial neighborhood relationship is used to correct the misclassified ...

  13. High spatial resolution NO2 tropospheric slant columns retrieved from OMI spatial-zoom spectra using an earthshine reference

    NASA Astrophysics Data System (ADS)

    Anand, Jasdeep S.; Leigh, Roland J.; Monks, Paul S.

    2014-08-01

    Future satellite instruments measuring urban NO2 will need to have high spatio-temporal resolution in order to improve air quality model forecasts. However, the likely cost and data telemetry requirements for such instruments will be high with current techniques. In this work we propose a new retrieval algorithm for deriving tropospheric NO2 slant column densities (SCDs) by DOAS fitting an earthshine reference spectrum measured over the Pacific to account for stratospheric NO2, which would eliminate the need for a solar reference and simplify instrument and retrieval design. The retrieval is tested by fitting earthshine radiance spectra measured by the Ozone Measuring Instrument (OMI) during its spatial-zoom mode (nadir pixel size: 13 x 12 km2) and super-zoom mode (nadir pixel size: 13 x 3 km2) using a Pacific reference spectrum. Transects taken over urban areas showed that the retrieval appears to retrieve tropospheric NO2 SCDs with good agreement with the operational L2 DOMINO product over regions with high NOx emissions. The retrieval also appeared to supress across-track striping without the need for a posteriori correction and showed sensitivity to absorption due to sand and liquid water over deserts and oceans. Comparisons with operational-scale retrievals also showed improved SCD precision, if random noise is expected to be the cause of retrieval uncertainty.

  14. An advanced image processing method to improve the spatial resolution of ion radiographies

    NASA Astrophysics Data System (ADS)

    Krah, N.; Testa, M.; Brons, S.; Jäkel, O.; Parodi, K.; Voss, B.; Rinaldi, I.

    2015-11-01

    We present an optimization method to improve the spatial resolution and the water equivalent thickness (WET) accuracy of ion radiographies. The method is designed for imaging systems measuring for each actively scanned beam spot the lateral position of the pencil beam and at the same time the Bragg curve (behind the target) in discrete steps without relying on tracker detectors to determine the ion trajectory before and after the irradiated volume. Specifically, the method was used for an imaging set-up consisting of a stack of 61 parallel-plate ionization chambers (PPIC) interleaved with absorber plates of polymethyl methacrylate (PMMA) working as a range telescope. The method uses not only the Bragg peak position, but approximates the entire measured Bragg curve as a superposition of differently shifted Bragg curves. Their relative weights allow to reconstruct the distribution of thickness around each scan spot of a heterogeneous phantom. The approach also allows merging the ion radiography with the geometric information of a co-registered x-ray radiography in order to increase its spatial resolution. The method was tested using Monte Carlo simulated and experimental proton radiographies of a PMMA step phantom and an anthropomorphic head phantom. For the step phantom, the effective spatial resolution was found to be 6 and 4 times higher than the nominal resolution for the simulated and experimental radiographies, respectively. For the head phantom, a gamma index was calculated to quantify the conformity of the simulated proton radiographies with a digitally reconstructed radiography (DRR) obtained from an x-ray CT and properly converted into WET. For a distance-to-agreement (DTA) of 2.5 mm and a relative WET difference (RWET) of 2.5%, the passing ratio was 100%/85% for the optimized/non-optimized case, respectively. When the optimized proton radiography was merged with the co-registered DRR, the passing ratio was 100% at DTA  =  1.3 mm and RWET

  15. Experimental Estimation of CLASP Spatial Resolution: Results of the Instrument's Optical Alignment

    NASA Technical Reports Server (NTRS)

    Giono, Gabrial; Katsukawa, Yukio; Ishikawa, Ryoko; Narukage, Noriyuki; Bando, Takamasa; Kano, Ryohei; Suematsu, Yoshinori; Kobayashi, Ken; Winebarger, Amy; Auchere, Frederic

    2015-01-01

    The Chromospheric Lyman-Alpha SpectroPolarimeter (CLASP) is a sounding-rocket experiment currently being built at the National Astronomical Observatory of Japan. This instrument aims to probe for the first time the magnetic field strength and orientation in the solar upper-chromosphere and lower-transition region. CLASP will measure the polarization of the Lyman-Alpha line (121.6nm) with an unprecedented accuracy, and derive the magnetic field information through the Hanle effect. Although polarization accuracy and spectral resolution are crucial for the Hanle effect detection, spatial resolution is also important to get reliable context image via the slit-jaw camera. As spatial resolution is directly related with the alignment of optics, it is also a good way of ensuring the alignment of the instrument to meet the scientific requirement. This poster will detail the experiments carried out to align CLASP's optics (telescope and spectrograph), as both part of the instrument were aligned separately. The telescope was aligned in double-pass mode, and a laser interferometer (He-Ne) was used to measure the telescope's wavefront error (WFE). The secondary mirror tilt and position were adjusted to remove comas and defocus aberrations from the WFE. Effect of gravity on the WFE measurement was estimated and the final WFE derived in zero-g condition for CLASP telescope will be presented. In addition, an estimation of the spot shape and size derived from the final WFE will also be shown. The spectrograph was aligned with a custom procedure: because Ly-??light is absorbed by air, the spectrograph's off-axis parabolic mirrors were aligned in Visible Light (VL) using a custom-made VL grating instead of the flight Ly-? grating. Results of the alignment in Visible Light will be shown and the spot shape recorded with CCDs at various position along the slit will be displayed. Results from both alignment experiment will be compared to the design requirement, and will be combined in

  16. Investigating the spatial resolution characteristics of a monolithic scintillation detector for pet

    NASA Astrophysics Data System (ADS)

    Kaul, Madhuri

    A key component of a PET system is the detection of the coincident gamma rays associated with positron decay. For most applications, the modern commercial scanners are limited by sensitivity. Although essentially all current commercial PET systems use pixelated designs, there has been a resurgence of the use of continuous crystal designs, particularly for preclinical scanner designs. There has also been a move away from the traditional Anger logic style of position decoding toward implementation of statistical estimation algorithms to locate an event in two or three dimensions. Continuous crystals offer advantages of improved position sampling, reduced dead space, and the ability to calibrate light-spread to measure the depth-of-interaction (DOI) to reduce parallax errors. The aim of this thesis is to study the factors that affect the performance of continuous crystals in an attempt to achieve the best trade-off between light-output, stopping power, light-spread, and sampling, while maintaining high sensitivity and good spatial and energy resolution. The methodology includes a combination of Monte Carlo simulations and experiments with continuous LYSO crystals of various thicknesses, with particular focus on a 25-mm thick crystal, which is on par with the pixels used in clinical scanners. Non-invasive techniques involving the use of sandpaper, paints, and films are used to maximize the light extraction from the crystal, and to reduce the edge effects. The effect of DOI on the light spread is investigated and a DOI calibration technique is implemented, which allows for a 2-level depth separation of events. Lastly, a more invasive technique of cutting slots into the crystal surface is investigated to control the light spread within the crystal to improve the spatial resolution. Combining 8-mm deep slots with selective darkening of the crystal sides we improve the spatial resolution of the 25-mm thick LYSO crystal from 5.3 mm to 3.5 mm (FWHM) using Maximum Likelihood

  17. Predicting spatial variations of tree species richness in tropical forests from high-resolution remote sensing.

    PubMed

    Fricker, Geoffrey A; Wolf, Jeffrey A; Saatchi, Sassan S; Gillespie, Thomas W

    2015-10-01

    There is an increasing interest in identifying theories, empirical data sets, and remote-sensing metrics that can quantify tropical forest alpha diversity at a landscape scale. Quantifying patterns of tree species richness in the field is time consuming, especially in regions with over 100 tree species/ha. We examine species richness in a 50-ha plot in Barro Colorado Island in Panama and test if biophysical measurements of canopy reflectance from high-resolution satellite imagery and detailed vertical forest structure and topography from light detection and ranging (lidar) are associated with species richness across four tree size classes (>1, 1-10, >10, and >20 cm dbh) and three spatial scales (1, 0.25, and 0.04 ha). We use the 2010 tree inventory, including 204,757 individuals belonging to 301 species of freestanding woody plants or 166 ± 1.5 species/ha (mean ± SE), to compare with remote-sensing data. All remote-sensing metrics became less correlated with species richness as spatial resolution decreased from 1.0 ha to 0.04 ha and tree size increased from 1 cm to 20 cm dbh. When all stems with dbh > 1 cm in 1-ha plots were compared to remote-sensing metrics, standard deviation in canopy reflectance explained 13% of the variance in species richness. The standard deviations of canopy height and the topographic wetness index (TWI) derived from lidar were the best metrics to explain the spatial variance in species richness (15% and 24%, respectively). Using multiple regression models, we made predictions of species richness across Barro Colorado Island (BCI) at the 1-ha spatial scale for different tree size classes. We predicted variation in tree species richness among all plants (adjusted r² = 0.35) and trees with dbh > 10 cm (adjusted r² = 0.25). However, the best model results were for understory trees and shrubs (dbh 1-10 cm) (adjusted r² = 0.52) that comprise the majority of species richness in tropical forests. Our results indicate that high-resolution

  18. Predicting spatial variations of tree species richness in tropical forests from high-resolution remote sensing.

    PubMed

    Fricker, Geoffrey A; Wolf, Jeffrey A; Saatchi, Sassan S; Gillespie, Thomas W

    2015-10-01

    There is an increasing interest in identifying theories, empirical data sets, and remote-sensing metrics that can quantify tropical forest alpha diversity at a landscape scale. Quantifying patterns of tree species richness in the field is time consuming, especially in regions with over 100 tree species/ha. We examine species richness in a 50-ha plot in Barro Colorado Island in Panama and test if biophysical measurements of canopy reflectance from high-resolution satellite imagery and detailed vertical forest structure and topography from light detection and ranging (lidar) are associated with species richness across four tree size classes (>1, 1-10, >10, and >20 cm dbh) and three spatial scales (1, 0.25, and 0.04 ha). We use the 2010 tree inventory, including 204,757 individuals belonging to 301 species of freestanding woody plants or 166 ± 1.5 species/ha (mean ± SE), to compare with remote-sensing data. All remote-sensing metrics became less correlated with species richness as spatial resolution decreased from 1.0 ha to 0.04 ha and tree size increased from 1 cm to 20 cm dbh. When all stems with dbh > 1 cm in 1-ha plots were compared to remote-sensing metrics, standard deviation in canopy reflectance explained 13% of the variance in species richness. The standard deviations of canopy height and the topographic wetness index (TWI) derived from lidar were the best metrics to explain the spatial variance in species richness (15% and 24%, respectively). Using multiple regression models, we made predictions of species richness across Barro Colorado Island (BCI) at the 1-ha spatial scale for different tree size classes. We predicted variation in tree species richness among all plants (adjusted r² = 0.35) and trees with dbh > 10 cm (adjusted r² = 0.25). However, the best model results were for understory trees and shrubs (dbh 1-10 cm) (adjusted r² = 0.52) that comprise the majority of species richness in tropical forests. Our results indicate that high-resolution

  19. Quantitative materials contrast at high spatial resolution with a novel near-field scanning microwave microscope

    NASA Astrophysics Data System (ADS)

    Imtiaz, Atif

    A novel Near-Field Scanning Microwave Microscope (NSMM) has been developed where a Scanning Tunneling Microscope (STM) is used for tip-to-sample distance control. The technique is non-contact and non-destructive. The same tip is used for both STM and NSMM, and STM helps maintain the tip-to-sample distance at a nominal height of 1 nm. Due to this very small tip-to-sample separation, the contribution to the microwave signals due to evanescent (non-propagating) waves cannot be ignored. I describe different evanescent wave models developed so far to understand the complex tip-to-sample interaction at microwave frequencies. Propagating wave models are also discussed, since they are still required to understand some aspects of the tip-to-sample interaction. Numerical modeling is also discussed for these problems. I demonstrate the sensitivity of this novel microscope to materials property contrast. The materials contrast is shown in spatial variations on the surface of metal thin films, Boron-doped Semiconductor and Colossal Magneto-Resistive (CMR) thin films. The height dependence of the contrast shows sensitivity to nano-meter sized features when the tip-to-sample separation is below 100 nm. By adding a cone of height 4 nm to the tip, I am able to explain a 300 kHz deviation observed in the frequency shift signal, when tip-to-sample separation is less than 10 nm. In the absence of the cone, the frequency shift signal should continue to show the logarithmic behavior as a function of height. I demonstrate sub-micron spatial resolution with this novel microscope, both in tip-to-sample capacitance Cx and materials contrast in sheet resistance Rx. The spatial resolution in Cx is demonstrated to be at-least 2.5 nm on CMR thin films. The spatial resolution in Rx is shown to be sub-micron by measuring a variably Boron-doped Silicon sample which was prepared using the Focus Ion Beam (FIB) technique.

  20. The Need for High Spatial Resolution Multispectral Thermal Remote Sensing Data In Urban Heat Island Research

    NASA Technical Reports Server (NTRS)

    Quattrochi, Dale A.; Luvall, Jeffrey C.

    2006-01-01

    Although the study of the Urban Heat Island (UHI) effect dates back to the early 1800's when Luke Howard discovered London s heat island, it has only been with the advent of thermal remote sensing systems that the extent, characteristics, and impacts of the UHI have become to be understood. Analysis of the UHI effect is important because above all, this phenomenon can directly influence the health and welfare of urban residents. For example, in 1995, over 700 people died in Chicago due to heat-related causes. UHI s are characterized by increased temperature in comparison to rural areas and mortality rates during a heat wave increase exponentially with the maximum temperature, an effect that is exacerbated by the UHI. Aside from the direct impacts of the UHI on temperature, UHI s can produce secondary effects on local meteorology, including altering local wind patterns, increased development of clouds and fog, and increasing rates of precipitation either over, or downwind, of cities. Because of the extreme heterogeneity of the urban surface, in combination with the sprawl associated with urban growth, thermal infrared (TIR) remote sensing data have become of significant importance in understanding how land cover and land use characteristics affect the development and intensification of the UHI. TIR satellite data have been used extensively to analyze the surface temperature regimes of cities to help observe and measure the impacts of surface temperatures across the urban landscape. However, the spatial scales at which satellite TIR data are collected are for the most part, coarse, with the finest readily available TIR data collected by the Landsat ETM+ sensor at 60m spatial resolution. For many years, we have collected high spatial resolution (10m) data using an airborne multispectral TIR sensor over a number of cities across the United States. These high resolution data have been used to develop an understanding of how discrete surfaces across the urban environment

  1. Sensitivity of watershed attributes to spatial resolution and interpolation method of LiDAR DEMs in three distinct landscapes

    NASA Astrophysics Data System (ADS)

    Goulden, T.; Hopkinson, C.; Jamieson, R.; Sterling, S.

    2014-03-01

    This study investigates scaling relationships of watershed area and stream networks delineated from LiDAR DEMs. The delineations are tested against spatial resolution, including 1, 5, 10, 25, and 50 m, and interpolation method, including Inverse Distance Weighting (IDW), Moving Average (MA), Universal Kriging (UK), Natural Neighbor (NN), and Triangular Irregular Networks (TIN). Study sites include Mosquito Creek, Scotty Creek, and Thomas Brook, representing landscapes with high, low, and moderate change in elevation, respectively. Results show scale-dependent irregularities in watershed area due to spatial resolution at Thomas Brook and Mosquito Creek. The highest sensitivity of watershed area to spatial resolution occurred at Scotty Creek, due to high incidence of LiDAR sensor measurement error and subtle changes in elevation. Length of drainage networks did not show a scaling relationship with spatial resolution, due to algorithmic complications of the stream initiation threshold. Stream lengths of main channels at Thomas Brook and Mosquito Creek displayed systematic increases in length with increasing spatial resolution, described through an average fractal dimension of 1.059. The scaling relationship between stream length and DEM resolution allows estimation of stream lengths from low-resolution DEMs in the absence of high-resolution DEMs. Single stream validation at Thomas Brook showed the 1 m DEM produced the lowest length error and highest spatial accuracy, at 3.7% and 71.3%, respectively. Single stream validation at Mosquito Creek showed the 25 m DEM produced the lowest length error, and the 1 m DEM the highest spatial accuracy, at 0.6% and 61.0%, respectively.

  2. On the effects of spatial and spectral resolution on spatial-spectral target detection in SHARE 2012 and Bobcat 2013 hyperspectral imagery

    NASA Astrophysics Data System (ADS)

    Kaufman, Jason R.; Eismann, Michael T.; Ratliff, Bradley M.; Celenk, Mehmet

    2015-05-01

    Previous work with the Bobcat 2013 data set1 showed that spatial-spectral feature extraction on visible to near infrared (VNIR) hyperspectral imagery (HSI) led to better target detection and discrimination than spectral-only techniques; however, the aforementioned study could not consider the possible benefits of the shortwaveinfrared (SWIR) portion of the spectrum due to data limitations. In addition, the spatial resolution of the Bobcat 2013 imagery was fixed at 8cm without exploring lower spatial resolutions. In this work, we evaluate the tradeoffs in spatial and spectral resolution and spectral coverage between for a common set of targets in terms of their effects on spatial-spectral target detection performance. We show that for our spatial-spectral target detection scheme and data sets, the adaptive cosine estimator (ACE) applied to S-DAISY and pseudo Zernike moment (PZM) spatial-spectral features can distinguish between targets better than ACE applied only to the spectral imagery. In particular, S-DAISY operating on bands uniformly selected from the SWIR portion of ProSpecTIR-VS sensor imagery in conjunction with bands closely corresponding to the Airborne Real-time Cueing Hyperspectral Reconnaissance (ARCHER) sensor's VNIR bands (80 total) led to the best overall average performance in both target detection and discrimination.

  3. Spatial Structure of a Braided River: Metric Resolution Hydrodynamic Modeling Reveals What SWOT Might See

    NASA Astrophysics Data System (ADS)

    Schubert, J.; Sanders, B. F.; Andreadis, K.

    2013-12-01

    The Surface Water and Ocean Topography (SWOT) mission, currently under study by NASA (National Aeronautics and Space Administration) and CNES (Centre National d'Etudes Spatiales), is designed to provide global spatial measurements of surface water properties at resolutions better than 10 m and with centimetric accuracy. The data produced by SWOT will include irregularly spaced point clouds of the water surface height, with point spacings from roughly 2-50 m depending on a point's location within SWOT's swath. This could offer unprecedented insight into the spatial structure of rivers. Features that may be resolved include backwater profiles behind dams, drawdown profiles, uniform flow sections, critical flow sections, and even riffle-pool flow structures. In the event that SWOT scans a river during a major flood, it becomes possible to delineate the limits of the flood as well as the spatial structure of the water surface elevation, yielding insight into the dynamic interaction of channels and flood plains. The Platte River in Nebraska, USA, is a braided river with a width and slope of approximately 100 m and 100 cm/km, respectively. A 1 m resolution Digital Terrain Model (DTM) of the river basin, based on airborne lidar collected during low-flow conditions, was used to parameterize a two-dimensional, variable resolution, unstructured grid, hydrodynamic model that uses 3 m resolution triangles in low flow channels and 10 m resolution triangles in the floodplain. Use of a fine resolution mesh guarantees that local variability in topography is resolved, and after applying the hydrodynamic model, the effects of topographic variability are expressed as variability in the water surface height, depth-averaged velocity and flow depth. Flow is modeled over a reach length of 10 km for multi-day durations to capture both frequent (diurnal variations associated with regulated flow) and infrequent (extreme flooding) flow phenomena. Model outputs reveal a number of interesting

  4. Effect of spatial resolution on remote sensing estimation of total evaporation in the uMngeni catchment, South Africa

    NASA Astrophysics Data System (ADS)

    Shoko, Cletah; Clark, David; Mengistu, Michael; Dube, Timothy; Bulcock, Hartley

    2015-01-01

    This study evaluated the effect of two readily available multispectral sensors: the newly launched 30 m spatial resolution Landsat 8 and the long-serving 1000 m moderate resolution imaging spectroradiometer (MODIS) datasets in the spatial representation of total evaporation in the heterogeneous uMngeni catchment, South Africa, using the surface energy balance system model. The results showed that sensor spatial resolution plays a critical role in the accurate estimation of energy fluxes and total evaporation across a heterogeneous catchment. Landsat 8 estimates showed better spatial representation of the biophysical parameters and total evaporation for different land cover types, due to the relatively higher spatial resolution compared to the coarse spatial resolution MODIS sensor. Moreover, MODIS failed to capture the spatial variations of total evaporation estimates across the catchment. Analysis of variance (ANOVA) results showed that MODIS-based total evaporation estimates did not show any significant differences across different land cover types (one-way ANOVA; F1.924=1.412, p=0.186). However, Landsat 8 images yielded significantly different estimates between different land cover types (one-way ANOVA; F1.993=5.185, p<0.001). The validation results showed that Landsat 8 estimates were more comparable to eddy covariance (EC) measurements than the MODIS-based total evaporation estimates. EC measurement on May 23, 2013, was 3.8 mm/day, whereas the Landsat 8 estimate on the same day was 3.6 mm/day, with MODIS showing significantly lower estimates of 2.3 mm/day. The findings of this study underscore the importance of spatial resolution in estimating spatial variations of total evaporation at the catchment scale, thus, they provide critical information on the relevance of the readily available remote sensing products in water resources management in data-scarce environments.

  5. Spatially encoded pulse sequences for the acquisition of high resolution NMR spectra in inhomogeneous fields

    NASA Astrophysics Data System (ADS)

    Shapira, Boaz; Frydman, Lucio

    2006-09-01

    We have recently proposed a protocol for retrieving nuclear magnetic resonance (NMR) spectra based on a spatially-dependent encoding of the MR interactions. It has also been shown that the spatial selectivity with which spins are manipulated during such encoding opens up new avenues towards the removal of magnetic field inhomogeneities; not by demanding extreme Bo field uniformities, but rather by compensating for the dephasing effects introduced by the field distribution at a radiofrequency excitation and/or refocusing level. The present study discusses in further detail a number of strategies deriving from this principle, geared at acquiring both uni- as well as multi-dimensional spectroscopic data at high resolution conditions. Different variants are presented, tailored according to the relative sensitivity and chemical nature of the spin system being explored. In particular a simple multi-scan experiment is discussed capable of affording substantial improvements in the spectral resolution, at nearly no sensitivity or scaling penalties. This new compensation scheme is therefore well-suited for the collection of high-resolution data in low-field systems possessing limited signal-to-noise ratios, where magnetic field heterogeneities might present a serious obstacle. Potential areas of applications of these techniques include high-field in vivo NMR studies in regions near tissue/air interfaces, clinical low field MR spectroscopy on relatively large off-center volumes difficult to shim, and ex situ NMR. The principles of the different compensation methods are reviewed and experimentally demonstrated for one-dimensional inhomogeneities; further improvements and extensions are briefly discussed.

  6. Estimation of grassland use intensities based on high spatial resolution LAI time series

    NASA Astrophysics Data System (ADS)

    Asam, S.; Klein, D.; Dech, S.

    2015-04-01

    The identification and surveillance of agricultural management and the measurement of biophysical canopy parameters in grasslands is relevant for environmental protection as well as for political and economic reasons, as proper grassland management is partly subsidized. An ideal monitoring tool is remote sensing due to its area wide continuous observations. However, due to small-scaled land use patterns in many parts of central Europe, a high spatial resolution is needed. In this study, the feasibility of RapidEye data to derive leaf area index (LAI) time series and to relate them to grassland management practices is assessed. The study area is the catchment of river Ammer in southern Bavaria, where agricultural areas are mainly grasslands. While extensively managed grasslands are maintained with one to two harvests per year and no or little fertilization, intensive cultivation practices compass three to five harvests per year and turnover pasturing. Based on a RapidEye time series from 2011 with spatial resolution of 6.5 meters, LAI is derived using the inverted radiation transfer model PROSAIL. The LAI in this area ranges from 1.5 to 7.5 over the vegetation period and is estimated with an RMSE between 0.7 and 1.1. The derived LAI maps cover 85 % of the study area's grasslands at least seven times. Using statistical metrics of the LAI time series, different grassland management types can be identified: very intensively managed meadows, intensively managed meadows, intensively managed pastures, and extensively managed meadows and moor. However, a precise identification of the mowing dates highly depends on the coincidence with satellite data acquisitions. Further analysis should focus therefor on the selection of the temporal resolution of the time series as well as on the performance of further vegetation parameters and indices compared to LAI.

  7. Statistical model based iterative reconstruction (MBIR) in clinical CT systems. Part II. Experimental assessment of spatial resolution performance

    SciTech Connect

    Li, Ke; Chen, Guang-Hong; Garrett, John; Ge, Yongshuai

    2014-07-15

    Purpose: Statistical model based iterative reconstruction (MBIR) methods have been introduced to clinical CT systems and are being used in some clinical diagnostic applications. The purpose of this paper is to experimentally assess the unique spatial resolution characteristics of this nonlinear reconstruction method and identify its potential impact on the detectabilities and the associated radiation dose levels for specific imaging tasks. Methods: The thoracic section of a pediatric phantom was repeatedly scanned 50 or 100 times using a 64-slice clinical CT scanner at four different dose levels [CTDI{sub vol} =4, 8, 12, 16 (mGy)]. Both filtered backprojection (FBP) and MBIR (Veo{sup ®}, GE Healthcare, Waukesha, WI) were used for image reconstruction and results were compared with one another. Eight test objects in the phantom with contrast levels ranging from 13 to 1710 HU were used to assess spatial resolution. The axial spatial resolution was quantified with the point spread function (PSF), while the z resolution was quantified with the slice sensitivity profile. Both were measured locally on the test objects and in the image domain. The dependence of spatial resolution on contrast and dose levels was studied. The study also features a systematic investigation of the potential trade-off between spatial resolution and locally defined noise and their joint impact on the overall image quality, which was quantified by the image domain-based channelized Hotelling observer (CHO) detectability index d′. Results: (1) The axial spatial resolution of MBIR depends on both radiation dose level and image contrast level, whereas it is supposedly independent of these two factors in FBP. The axial spatial resolution of MBIR always improved with an increasing radiation dose level and/or contrast level. (2) The axial spatial resolution of MBIR became equivalent to that of FBP at some transitional contrast level, above which MBIR demonstrated superior spatial resolution than

  8. Development of a high spatial resolution neutron imaging system and performance evaluation

    NASA Astrophysics Data System (ADS)

    Cao, Lei

    The combination of a scintillation screen and a charged coupled device (CCD) camera is a digitized neutron imaging technology that has been widely employed for research and industry application. The maximum of spatial resolution of scintillation screens is in the range of 100 mum and creates a bottleneck for the further improvement of the overall system resolution. In this investigation, a neutron sensitive micro-channel plate (MCP) detector with pore pitch of 11.4 mum is combined with a cooled CCD camera with a pixel size of 6.8 mum to provide a high spatial resolution neutron imaging system. The optical path includes a high reflection front surface mirror for keeping the camera out of neutron beam and a macro lens for achieving the maximum magnification that could be achieved. All components are assembled into an aluminum light tight box with heavy radiation shielding to protect the camera as well as to provide a dark working condition. Particularly, a remote controlled stepper motor is also integrated into the system to provide on-line focusing ability. The best focus is guaranteed through use of an algorithm instead of perceptual observation. An evaluation routine not previously utilized in the field of neutron radiography is developed in this study. Routines like this were never previously required due to the lower resolution of other systems. Use of the augulation technique to obtain presampled MTF addresses the problem of aliasing associated with digital sampling. The determined MTF agrees well with the visual inspection of imaging a testing target. Other detector/camera combinations may be integrated into the system and their performances are also compared. The best resolution achieved by the system at the TRIGA Mark II reactor at the University of Texas at Austin is 16.2 lp/mm, which is equivalent to a minimum resolvable spacing of 30 mum. The noise performance of the device is evaluated in terms of the noise power spectrum (NPS) and the detective quantum

  9. Resolving the spatial relationship between intracellular components by dual color super resolution optical fluctuations imaging (SOFI)

    PubMed Central

    Gallina, Maria Elena; Xu, Jianmin; Dertinger, Thomas; Aizer, Adva; Shav-Tal, Yaron; Weiss, Shimon

    2013-01-01

    Background Multi-color super-resolution (SR) imaging microscopy techniques can resolve ultrastructura relationships between- and provide co-localization information of- different proteins inside the cell or even within organelles at a higher resolution than afforded by conventional diffraction-limited imaging. While still very challenging, important SR colocalization results have been reported in recent years using STED, PALM and STORM techniques. Results In this work, we demonstrate dual-color Super Resolution Optical Fluctuations Imaging (SOFI) using a standard far-field fluorescence microscope and different color blinking quantum dots. We define the spatial relationship between hDcp1a, a processing body (P-body, PB) protein, and the tubulin cytoskeletal network. Our finding could open up new perspectives on the role of the cytoskeleton in PB formation and assembly. Further insights into PB internal organization are also reported and discussed. Conclusions Our results demonstrate the suitability and facile use of multi-color SOFI for the investigation of intracellular ultrastructures. PMID:24324919

  10. Force scanning: A rapid, high-resolution approach for spatial mechanical property mapping

    PubMed Central

    Darling, E M

    2011-01-01

    Atomic force microscopy (AFM) can be used to co-localize mechanical properties and topographical features through property mapping techniques. The most common approach for testing biological materials at the micro-and nano-scales is force mapping, which involves taking individual force curves at discrete sites across a region of interest. Limitations of force mapping include long testing times and low resolution. While newer AFM methodologies, like modulated scanning and torsional oscillation, circumvent this problem, their adoption for biological materials has been limited. This could be due to their need for specialized software algorithms and/or hardware. The objective of this study is to develop a novel force scanning technique using AFM to rapidly capture high-resolution topographical images of soft biological materials while simultaneously quantifying their mechanical properties. Force scanning is a straight-forward methodology applicable to a wide range of materials and testing environments, requiring no special modification to standard AFMs. Essentially, if a contact mode image can be acquired, then force scanning can be used to produce a spatial modulus map. The current study first validates this technique using agarose gels, comparing results to the standard force mapping approach. Biologically relevant demonstrations are then presented for high-resolution modulus mapping of individual cells, cell-cell interfaces, and articular cartilage tissue. PMID:21411911

  11. High Spatial Resolution Europa Coverage by the Galileo Near Infrared Mapping Spectrometer (NIMS)

    NASA Technical Reports Server (NTRS)

    1997-01-01

    The NIMS instrument on the Galileo spacecraft, which is being used to map the mineral and ice properties over the surfaces of the Jovian moons, produces global spectral images at modest spatial resolution and high resolution spectral images for small selected regions on the satellites. This map illustrates the high resolution coverage of Europa obtained by NIMS through the April 1997 G7 orbit.

    The areas covered are displayed on a Voyager-derived map. A good sampling of the dark trailing-side material (180 to 360 degrees) has been obtained, with less coverage of Europa's leading side.

    The false-color composites use red, green and blue to represent the infrared brightnesses at 0.7, 1.51 and 1.82 microns respectively. Considerable variations are evident and are related to the composition and sizes of the surface grains.

    The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.

    The Jet Propulsion Laboratory, Pasadena, CA manages the mission for NASA's Office of Space Science, Washington, DC.

    This image and other images and data received from Galileo are posted on the World Wide Web, on the Galileo mission home page at URL http://galileo.jpl.nasa.gov.

  12. Spatial disaggregation of satellite-derived irradiance using a high-resolution digital elevation model

    SciTech Connect

    Ruiz-Arias, Jose A.; Tovar-Pescador, Joaquin; Cebecauer, Tomas; Suri, Marcel

    2010-09-15

    Downscaling of the Meteosat-derived solar radiation ({proportional_to}5 km grid resolution) is based on decomposing the global irradiance and correcting the systematic bias of its components using the elevation and horizon shadowing that are derived from the SRTM-3 digital elevation model (3 arc sec resolution). The procedure first applies the elevation correction based on the difference between coarse and high spatial resolution. Global irradiance is split into direct, diffuse circumsolar and diffuse isotropic components using statistical models, and then corrections due to terrain shading and sky-view fraction are applied. The effect of reflected irradiance is analysed only in the theoretical section. The method was applied in the eastern Andalusia, Spain, and the validation was carried out for 22 days on April, July and December 2006 comparing 15-min estimates of the satellite-derived solar irradiance and observations from nine ground stations. Overall, the corrections of the satellite estimates in the studied region strongly reduced the mean bias of the estimates for clear and cloudy days from roughly 2.3% to 0.4%. (author)

  13. Assessing NO2 variability over urban areas at high spatial resolution

    NASA Astrophysics Data System (ADS)

    Silverman, M. L.; Szykman, J.; Knepp, T. N.; Chen, G.; Crawford, J. H.; Janz, S. J.; Kowalewski, M. G.; Fishman, J.

    2013-12-01

    Nitrogen dioxide (NO2) is a short-lived species within the troposphere, contributing to the production of ozone and aerosols. It is concentrated in urban and industrial areas where an abundance of point and mobile sources exist. Due to its short lifetime, it is difficult to capture the variability of NO2 and represent it within atmospheric chemistry transport models. Understanding this variability is important for emission controls, health impacts, and photochemistry. This analysis uses in situ aircraft measurements collected during ARCTAS-CARB, ICARTT, TexAQS-2000, TexAQS-2006, and DISCOVER-AQ as well as high spatial resolution column measurements of NO2 from the NASA GSFC Airborne Compact Atmospheric Mapper (ACAM) instrument collected during the first DISCOVER-AQ deployment, to assess the variability over urban areas. First order structure functions are used to generate statistics over a range of spatial scales. Column density is calculated from the DISCOVER-AQ profiles to assess the variability of a column within the aircraft profile. Results show that spatial variability depends on the airmass being sampled, polluted versus background conditions.

  14. Neuronal nonlinearity explains greater visual spatial resolution for darks than lights

    PubMed Central

    Kremkow, Jens; Jin, Jianzhong; Komban, Stanley J.; Wang, Yushi; Lashgari, Reza; Li, Xiaobing; Jansen, Michael; Zaidi, Qasim; Alonso, Jose-Manuel

    2014-01-01

    Astronomers and physicists noticed centuries ago that visual spatial resolution is higher for dark than light stimuli, but the neuronal mechanisms for this perceptual asymmetry remain unknown. Here we demonstrate that the asymmetry is caused by a neuronal nonlinearity in the early visual pathway. We show that neurons driven by darks (OFF neurons) increase their responses roughly linearly with luminance decrements, independent of the background luminance. However, neurons driven by lights (ON neurons) saturate their responses with small increases in luminance and need bright backgrounds to approach the linearity of OFF neurons. We show that, as a consequence of this difference in linearity, receptive fields are larger in ON than OFF thalamic neurons, and cortical neurons are more strongly driven by darks than lights at low spatial frequencies. This ON/OFF asymmetry in linearity could be demonstrated in the visual cortex of cats, monkeys, and humans and in the cat visual thalamus. Furthermore, in the cat visual thalamus, we show that the neuronal nonlinearity is present at the ON receptive field center of ON-center neurons and ON receptive field surround of OFF-center neurons, suggesting an origin at the level of the photoreceptor. These results demonstrate a fundamental difference in visual processing between ON and OFF channels and reveal a competitive advantage for OFF neurons over ON neurons at low spatial frequencies, which could be important during cortical development when retinal images are blurred by immature optics in infant eyes. PMID:24516130

  15. Neuronal nonlinearity explains greater visual spatial resolution for darks than lights.

    PubMed

    Kremkow, Jens; Jin, Jianzhong; Komban, Stanley J; Wang, Yushi; Lashgari, Reza; Li, Xiaobing; Jansen, Michael; Zaidi, Qasim; Alonso, Jose-Manuel

    2014-02-25

    Astronomers and physicists noticed centuries ago that visual spatial resolution is higher for dark than light stimuli, but the neuronal mechanisms for this perceptual asymmetry remain unknown. Here we demonstrate that the asymmetry is caused by a neuronal nonlinearity in the early visual pathway. We show that neurons driven by darks (OFF neurons) increase their responses roughly linearly with luminance decrements, independent of the background luminance. However, neurons driven by lights (ON neurons) saturate their responses with small increases in luminance and need bright backgrounds to approach the linearity of OFF neurons. We show that, as a consequence of this difference in linearity, receptive fields are larger in ON than OFF thalamic neurons, and cortical neurons are more strongly driven by darks than lights at low spatial frequencies. This ON/OFF asymmetry in linearity could be demonstrated in the visual cortex of cats, monkeys, and humans and in the cat visual thalamus. Furthermore, in the cat visual thalamus, we show that the neuronal nonlinearity is present at the ON receptive field center of ON-center neurons and ON receptive field surround of OFF-center neurons, suggesting an origin at the level of the photoreceptor. These results demonstrate a fundamental difference in visual processing between ON and OFF channels and reveal a competitive advantage for OFF neurons over ON neurons at low spatial frequencies, which could be important during cortical development when retinal images are blurred by immature optics in infant eyes. PMID:24516130

  16. Super-Spatial- and -Spectral-Resolution in Vibrational Imaging via Saturated Coherent Anti-Stokes Raman Scattering

    NASA Astrophysics Data System (ADS)

    Yonemaru, Yasuo; Palonpon, Almar F.; Kawano, Shogo; Smith, Nicholas I.; Kawata, Satoshi; Fujita, Katsumasa

    2015-07-01

    We demonstrate a vibrational microscopy technique with subdiffraction spatial resolution by the use of saturation of coherent anti-Stokes Raman scattering (CARS). The saturated CARS signals effectively produce a reduced point-spread function at harmonic frequencies, which is extracted by temporal modulation of the pump beam and demodulation of the CARS signal. An increase in spectral resolution and suppression of the nonresonant background signal accompany the spatial- resolution enhancement. Our simple, enhanced CARS technique promises to be useful in studying molecules in gas and liquid phases as well as soft condensed-matter systems.

  17. Spatial resolution of the pain system: a proximal-to-distal gradient of sensitivity revealed with psychophysical testing.

    PubMed

    Weissman-Fogel, Irit; Brayer-Zwi, Nurit; Defrin, Ruth

    2012-01-01

    The spatial resolution of the pain system has not been studied in depth, and results are contradictory regarding the gradient of spatial resolution. Microneurographic recordings have revealed smaller receptive fields and higher density of nociceptors in more distal than proximal leg regions, whereas histological studies report higher density of C-fibers in more proximal than distal body regions. Due to this controversy, we conducted various psychophysical tests in order to examine the nociceptive spatial resolution and its gradient. Heat-pain threshold (HPT), perceived pain intensity, spatial summation (SS) of pain, two-point discrimination (2PD) of pain, and pain localization were measured in four body regions: upper back, thigh, lower leg, and foot. The highest HPT was demonstrated in the lower leg as compared with more proximal regions (P < 0.0001). SS was observed in all the regions and was found to be smallest in the foot (P < 0.05). The smallest 2PD and localization distances were found in the foot (P < 0.01) as compared with the lower leg and upper back. It appears that the nociceptive spatial resolution has a proximal-to-distal pattern of performance, namely that the spatial resolution of pain is finer in more distal than proximal body regions, similar to that of the touch system.

  18. Multi-beam synchrotron infrared chemical imaging with high spatial resolution: Beamline realization and first reports on image restoration

    NASA Astrophysics Data System (ADS)

    Nasse, Michael J.; Mattson, Eric C.; Reininger, Ruben; Kubala, Tim; Janowski, Sebastian; El-Bayyari, Zuheir; Hirschmugl, Carol J.

    2011-09-01

    Table-top Fourier transform infrared (FT-IR) imaging using focal plane array (FPA) multi-element detectors is an increasingly popular chemical microscopy technique because it can provide microspectroscopic images of large sample areas in short times at moderate spatial resolution. The novel IR beamline IRENI at the Synchrotron Radiation Center (Wisconsin, USA), the first dedicated multi-beam synchrotron-based FT-IR imaging system, offers, within minutes, high quality chemical images at the highest available spatial resolution (diffraction-limited at all mid-IR wavelengths) with a pixel size of 0.54×0.54 μm 2 for transmission measurements. Due to this very high spatial sampling, mathematical image enhancement algorithms such as deconvolution and total variation (TV) reconstruction can be implemented to improve image contrast and thus spatial resolution. This is demonstrated for US Air force (USAF) targets, micron-sized aluminum beads, and a single living algal cell.

  19. Sensitivity of snow models to the spatial and temporal resolution of meteorological forcing

    NASA Astrophysics Data System (ADS)

    Terzago, Silvia; von Hardenberg, Jost; Palazzi, Elisa; Cassardo, Claudio; Balsamo, Gianpaolo; Provenzale, Antonello

    2014-05-01

    The simulation of snowpack dynamics in high elevation environments is facing the problem of the uncertainty and the spatial representativeness of the input data, owing to a high spatial variability of meteorological parameters in complex topography. In this study we evaluate the land-surface model UTOPIA (University of TOrino land Process Interaction in Atmosphere) single-layer snow scheme in order to assess its capability in reproducing the snow dynamics, i.e. the accumulation/melting processes and the snow depth temporal variability, and we compare it to the snow module of the Hydrology-Tiled ECMWF Scheme for Surface Exchange over Land (HTESSEL) of the European Centre for Medium-range Weather Forecasts (ECMWF). The validation is performed using high-quality datasets provided by the two experimental snow-meteorological observation sites in Torgnon (2150 m a.s.l.) and Col de Porte (1325 m a.s.l.), located in the Italian and French Alps respectively. We assess the sensitivity of the models to the spatial and temporal resolution of the input data, comparing the case in which high-quality and high-frequency data are provided by individual stations at specific observation sites, as those employed in this study for validation, to the case in which data are provided by gridded datasets based on the spatial-temporal interpolation of surface station measurements. Interpolation, in its various forms, represents a source of uncertainty in the final gridded product, thus we evaluate the quality of the models estimates in case of increasing uncertainty in the input data.

  20. Chemistry, mineralogy and petrology of seven greater than 1 mm fragments from Mare Crisium

    NASA Technical Reports Server (NTRS)

    Laul, J. C.; Vaniman, D. T.; Papike, J. J.

    1978-01-01

    Results are summarized for a consortium study of the chemistry, mineralogy, and petrology of seven Luna 24 fragments greater than 1 mm in size and having a mass of about 2 mg each. The fragments include four samples of mare ferrobasalt composition, one vitrophyre with the composition of a Mg-rich VLT mare basalt, one agglutinate, and one plagioclase fragment. It is found that: (1) the ferrobasalt is a highly fractionated mare rock very low in alkalis and TiO2, is similar to the less fractionate Apollo 17 VLT basalts, and is quite low in large-ion lithophile trace-element content; (2) the rare-earth-element patterns of the ferrobasalts are typical of VLT basalt, but some ophitic basalts have positive Eu anomalies, while others have negative Eu anomalies typical of mare basalts; and (3) the agglutinate is feldspathic and similar in composition to soil fines in Fe, Cr, Ca, and Al.

  1. Retrieving Aerosol in a Cloudy Environment: Aerosol Availability as a Function of Spatial and Temporal Resolution

    NASA Technical Reports Server (NTRS)

    Remer, Lorraine A.; Mattoo, Shana; Levy, Robert C.; Heidinger, Andrew; Pierce, R. Bradley; Chin, Mian

    2011-01-01

    The challenge of using satellite observations to retrieve aerosol properties in a cloudy environment is to prevent contamination of the aerosol signal from clouds, while maintaining sufficient aerosol product yield to satisfy specific applications. We investigate aerosol retrieval availability at different instrument pixel resolutions, using the standard MODIS aerosol cloud mask applied to MODIS data and a new GOES-R cloud mask applied to GOES data for a domain covering North America and surrounding oceans. Aerosol availability is not the same as the cloud free fraction and takes into account the technqiues used in the MODIS algorithm to avoid clouds, reduce noise and maintain sufficient numbers of aerosol retrievals. The inherent spatial resolution of each instrument, 0.5x0.5 km for MODIS and 1x1 km for GOES, is systematically degraded to 1x1 km, 2x2 km, 4x4 km and 8x8 km resolutions and then analyzed as to how that degradation would affect the availability of an aerosol retrieval, assuming an aerosol product resolution at 8x8 km. The results show that as pixel size increases, availability decreases until at 8x8 km 70% to 85% of the retrievals available at 0.5 km have been lost. The diurnal pattern of aerosol retrieval availability examined for one day in the summer suggests that coarse resolution sensors (i.e., 4x4 km or 8x8 km) may be able to retrieve aerosol early in the morning that would otherwise be missed at the time of current polar orbiting satellites, but not the diurnal aerosol properties due to cloud cover developed during the day. In contrast finer resolution sensors (i.e., 1x1 km or 2x2 km) have much better opportunity to retrieve aerosols in the partly cloudy scenes and better chance of returning the diurnal aerosol properties. Large differences in the results of the two cloud masks designed for MODIS aerosol and GOES cloud products strongly reinforce that cloud masks must be developed with specific purposes in mind and that a generic cloud mask

  2. Developing a CCD camera with high spatial resolution for RIXS in the soft X-ray range

    NASA Astrophysics Data System (ADS)

    Soman, M. R.; Hall, D. J.; Tutt, J. H.; Murray, N. J.; Holland, A. D.; Schmitt, T.; Raabe, J.; Schmitt, B.

    2013-12-01

    The Super Advanced X-ray Emission Spectrometer (SAXES) at the Swiss Light Source contains a high resolution Charge-Coupled Device (CCD) camera used for Resonant Inelastic X-ray Scattering (RIXS). Using the current CCD-based camera system, the energy-dispersive spectrometer has an energy resolution (E/ΔE) of approximately 12,000 at 930 eV. A recent study predicted that through an upgrade to the grating and camera system, the energy resolution could be improved by a factor of 2. In order to achieve this goal in the spectral domain, the spatial resolution of the CCD must be improved to better than 5 μm from the current 24 μm spatial resolution (FWHM). The 400 eV-1600 eV energy X-rays detected by this spectrometer primarily interact within the field free region of the CCD, producing electron clouds which will diffuse isotropically until they reach the depleted region and buried channel. This diffusion of the charge leads to events which are split across several pixels. Through the analysis of the charge distribution across the pixels, various centroiding techniques can be used to pinpoint the spatial location of the X-ray interaction to the sub-pixel level, greatly improving the spatial resolution achieved. Using the PolLux soft X-ray microspectroscopy endstation at the Swiss Light Source, a beam of X-rays of energies from 200 eV to 1400 eV can be focused down to a spot size of approximately 20 nm. Scanning this spot across the 16 μm square pixels allows the sub-pixel response to be investigated. Previous work has demonstrated the potential improvement in spatial resolution achievable by centroiding events in a standard CCD. An Electron-Multiplying CCD (EM-CCD) has been used to improve the signal to effective readout noise ratio achieved resulting in a worst-case spatial resolution measurement of 4.5±0.2 μm and 3.9±0.1 μm at 530 eV and 680 eV respectively. A method is described that allows the contribution of the X-ray spot size to be deconvolved from these

  3. Where should fine-resolution spatial heterogeneity be captured within Earth System Models?

    NASA Astrophysics Data System (ADS)

    Adam, J. C.; Hull, R.; Tague, C.; Reyes, J. J.; Liu, M.

    2015-12-01

    Land-atmosphere interactions impact the environment in many ways, such as through partially driving our climate system, and in changing the availability and usability of our natural resources. Earth System Models (EaSMs) are being used increasingly to explore these coupled dynamics from watershed to global scales. However, many EaSMs do not adequately represent landscape-scale spatial heterogeneity that influences land surface response, as relatively coarse resolution simulations are necessitated by computational limitations. Research is needed to understand which types of spatial heterogeneity, over which biomes and climate types, should be represented such that an EaSM accurately captures the aggregate land surface response to a changing climate. Spatial heterogeneity in a landscape arises due to differences in model forcings; in underlying soil, vegetation, and topographic properties that control moisture, energy and nutrient fluxes; and in land surface responses that arise due to spatially-organized connections. While our long-term goal is to understand how each of these sources should be represented in an EaSM, in this study we focus first on parameter heterogeneity. We apply the Regional Hydro-Ecological Simulation System (RHESSys), a distributed process-based model that was originally developed for catchment-scale applications. We explore the functional form of the hydrologic response of a RHESSys "patch" (a 200-400 m element with homogenous landscape parameters) to an invoked change. According to scale transition theory, a linear response makes it is possible to upscale (or aggregate) the model resolution without biasing the model response. We perform RHESSys simulations for more than 500 individual catchments within the Willamette and Yakima River basins in the Pacific Northwest region of the U.S. Each catchment was imposed with incremental perturbations of temperature and precipitation. The response curves for hydrologic variables such as

  4. High Spatial Resolution Airborne Multispectral Thermal Infrared Remote Sensing Data for Analysis of Urban Landscape Characteristics

    NASA Technical Reports Server (NTRS)

    Quattrochi, Dale A.; Luvall, Jeffrey C.; Estes, Maurice G., Jr.; Arnold, James E. (Technical Monitor)

    2000-01-01

    We have used airborne multispectral thermal infrared (TIR) remote sensing data collected at a high spatial resolution (i.e., 10m) over several cities in the United States to study thermal energy characteristics of the urban landscape. These TIR data provide a unique opportunity to quantify thermal responses from discrete surfaces typical of the urban landscape and to identify both the spatial arrangement and patterns of thermal processes across the city. The information obtained from these data is critical to understanding how urban surfaces drive or force development of the Urban Heat Island (UHI) effect, which exists as a dome of elevated air temperatures that presides over cities in contrast to surrounding non-urbanized areas. The UHI is most pronounced in the summertime where urban surfaces, such as rooftops and pavement, store solar radiation throughout the day, and release this stored energy slowly after sunset creating air temperatures over the city that are in excess of 2-4'C warmer in contrast with non-urban or rural air temperatures. The UHI can also exist as a daytime phenomenon with surface temperatures in downtown areas of cities exceeding 38'C. The implications of the UHI are significant, particularly as an additive source of thermal energy input that exacerbates the overall production of ground level ozone over cities. We have used the Airborne Thermal and Land Applications Sensor (ATLAS), flown onboard a Lear 23 jet aircraft from the NASA Stennis Space Center, to acquire high spatial resolution multispectral TIR data (i.e., 6 bandwidths between 8.2-12.2 (um) over Huntsville, Alabama, Atlanta, Georgia, Baton Rouge, Louisiana, Salt Lake City, Utah, and Sacramento, California. These TIR data have been used to produce maps and other products, showing the spatial distribution of heating and cooling patterns over these cities to better understand how the morphology of the urban landscape affects development of the UHI. In turn, these data have been used

  5. Higher Order spatial schemes and effective resolution in the COSMO model

    NASA Astrophysics Data System (ADS)

    Ogaja, Jack; Will, Andreas

    2014-05-01

    As reported by several authors the limited area models exhibit a substantial difference between the models horizontal grid and effective resolution. Usually the grid resolution is reported. At the same time the effect of increased model resolution is small in comparison to the increased computing costs (approx. one order of magnitude for half grid size). Furthermore, in the last years the computing power increased faster than the storage space. Higher order spatial discretisation schemes have the potential to increase the effective model resolution keeping the storage space needs constant and increasing the computational costs slightly. A 4th order horizontal discretisation of the Euler equations in the NWP and RCM COSMO model was implemented together with 2 types of the advection term discretisation. The first is an extension of the COSMO higher order discretisation by introduction of 4th order interpolations of the advecting velocity, denoted as C4. The second is a symmetric type of discretization of the advection term (Morinishi, 1999) which can be shown to conserve the 1st and 2nd moments of the advected quantity if the continuity equation is satisfied, here referred to as S4. Both convective schemes can be combined with 4th order discretization of the pressure gradient term, referred to as p4. To make the spatial schemes fully 4th order the metric coefficients and terms are discretised 4th order as well. The 4th order discretisations are referred to as C4p4 and S4p4 and complement the already existing schemes A3p2, A4p2, A5p2 and A6p2. Here AX denotes the central difference (2,4,6) and upwind (3,5) discretisation of the gradient of the advected velocity. The configuration used is the CLM Community standard configuration. This configuration used the A3p2 scheme together with horizontal diffusion coefficients of strength 0.25, referred to as d025. In cosmo_4.27 the new fast waves solver was used. Additional simulations have been conducted for S4p4d025, S4p4d0

  6. Ratiometric Organic Fibers for Localized and Reversible Ion Sensing with Micrometer‐Scale Spatial Resolution

    PubMed Central

    Moffa, Maria; Rinaldi, Rosaria

    2015-01-01

    A fundamental issue in biomedical and environmental sciences is the development of sensitive and robust sensors able to probe the analyte of interest, under physiological and pathological conditions or in environmental samples, and with very high spatial resolution. In this work, novel hybrid organic fibers that can effectively report the analyte concentration within the local microenvironment are reported. The nanostructured and flexible wires are prepared by embedding fluorescent pH sensors based on seminaphtho‐rhodafluor‐1‐dextran conjugate. By adjusting capsule/polymer ratio and spinning conditions, the diameter of the fibers and the alignment of the reporting capsules are both tuned. The hybrid wires display excellent stability, high sensitivity, as well as reversible response, and their operation relies on effective diffusional kinetic coupling of the sensing regions and the embedding polymer matrix. These devices are believed to be a powerful new sensing platform for clinical diagnostics, bioassays and environmental monitoring. PMID:26539625

  7. Spatial resolution limits for the localization of noise sources using direct sound mapping

    NASA Astrophysics Data System (ADS)

    Fernandez Comesaña, D.; Holland, K. R.; Fernandez-Grande, E.

    2016-08-01

    One of the main challenges arising from noise and vibration problems is how to identify the areas of a device, machine or structure that produce significant acoustic excitation, i.e. the localization of main noise sources. The direct visualization of sound, in particular sound intensity, has extensively been used for many years to locate sound sources. However, it is not yet well defined when two sources should be regarded as resolved by means of direct sound mapping. This paper derives the limits of the direct representation of sound pressure, particle velocity and sound intensity by exploring the relationship between spatial resolution, noise level and geometry. The proposed expressions are validated via simulations and experiments. It is shown that particle velocity mapping yields better results for identifying closely spaced sound sources than sound pressure or sound intensity, especially in the acoustic near-field.

  8. Design considerations for a high-spatial-resolution positron camera with dense-drift-space MWPC's

    SciTech Connect

    Del Guerra, A.; Perez-Mendez, V.; Schwartz, G.; Nelson, W.R.

    1982-10-01

    A multiplane Positron Cameris is proposed, made of six MWPC modules arranged to form the lateral surface of a hexagonal prism. Each module (50 x 50 cm/sup 2/) has a 2 cm thick lead-glass tube converter on both sides of a MWPC pressurized to 2 atm. Experimental measurements are presented to show how to reduce the parallax error by determining in which of the two converter layers the photon has interacted. The results of a detailed Monte Carlo calculation for the efficiency of this type of converter are shown to be in excellent agreement with the experimental measurements. The expected performance of the Positron Camera is presented: a true coincidence rate of 56,000 counts/s (with an equal accidental coincidence rate and a 30% Compton scatter contamination) and a spatial resolution better than 5.0 mm (FWHM) for a 400 ..mu.. Ci point-like source embedded in a 10 cm radius water phantom.

  9. Improving the Spatial Resolution of Neutron Imaging at Paul Scherrer Institut - The Neutron Microscope Project

    NASA Astrophysics Data System (ADS)

    Trtik, Pavel; Hovind, Jan; Grünzweig, Christian; Bollhalder, Alex; Thominet, Vincent; David, Christian; Kaestner, Anders; Lehmann, Eberhard H.

    Here we present results stemming from the first prototype of the Neutron Microscope instrument at Paul ScherrerInstitut (PSI). The instrument is based on a very thin gadolinium oxysulfide (Gd2O2S:Tb+) scintillator screen and a magnifying optics. The Neutron Microscope prototype has been tested at the ICON and the BOA beamlines at PSI and sub-10 μm features can be clearly resolved on a focussed ion beam (FIB) enhance test object - a gadolinium-based Siemens star. The spatial resolution of the images of the gadolinium-based Siemensstar assessed by Fourier ring correlation was about 7.6 μm. The outlook for future improvement of the Neutron Microscope system is presented.

  10. Polarization sensitive ultrafast mid-IR pump probe micro-spectrometer with diffraction limited spatial resolution.

    PubMed

    Kaucikas, M; Barber, J; Van Thor, J J

    2013-04-01

    A setup of ultrafast transient infrared IR spectrometer is described in this paper that employed Schwarzschild objectives to focus the probe beam to a diffraction limited spot. Thus measurements were performed with very high spatial resolution in the mid-IR spectral region. Furthermore, modulating the polarization of the probe light enabled detecting transient dichroism of the sample. These capabilities of the setup were applied to study transient absorption of Photosystem II core complex and to image an organized film of methylene blue chloride dye. Moreover, a study of noise sources in a pump probe measurement is presented. The predicted noise level of the current setup was 8.25 μOD in 10(4) acquisitions and compared very well with the experimental observation of 9.6 μOD.

  11. High spatial resolution IR observations of young stellar objects - A possible disk surrounding HL Tauri

    NASA Technical Reports Server (NTRS)

    Grasdalen, G. L.; Strom, S. E.; Strom, K. M.; Capps, R. W.; Thompson, D.; Castelaz, M.

    1984-01-01

    High spatial resolution images of the T Tauri star HL Tau were obtained at 1.6 microns and 2.2 microns. The original images as well as maximum entropy image reconstructions reveal a circumstellar envelope structure, similar at both wavelenghts, and extended along P.A. = 112 deg; the 10 percent width of the structure is 1.9 sec (300 AU at 160 pc). The extended structure is interpreted as light scattered toward earth by dust in a disk surrounding this young stellar object. Polarization measurements made at 2.2 microns support this hypothesis. The total solid particle mass is, at minimum, 5 x 10 to the -7th solar mass.

  12. Retrieving Crops Green Area Index from High Temporal and Spatial Resolution Remote Sensing Data

    NASA Astrophysics Data System (ADS)

    Veloso, A.; Demarez, V.; Ceschia, E.

    2012-04-01

    This paper aims at firstly evaluating the correspondence between Normalized Difference Vegetation Index (NDVI) products from Formosat-2 (F2) and SPOT sensors and then to perform a comparative analysis of two methods for retrieving Green Area Index from high spatial and temporal resolution satellite data (F2 and SPOT). For this purpose, an empirical approach using NDVI plus field data and a Neural Network approach using the PROSAIL model are compared over four different crops: maize, soybean, sunflower and wheat. The performance of both methods were evaluated and compared with in-situ direct (destructive) and indirect (hemispherical photos) measurements. Results suggest better performances for the empirical approach (R², RMSE). Still the physically-based method leads to good results (R², RMSE). The latter seems to be more promising due to its portability and independence from field measurements. Therefore new perspectives to improve this approach are being envisaged.

  13. Design considerations for a high-spatial-resolution positron camera with dense-drift-space MWPC's

    NASA Astrophysics Data System (ADS)

    Delguerra, A.; Perez-Mendez, V.; Schwartz, G.; Nelson, W. R.

    1982-10-01

    A multiplane Positron Camera is proposed, made of six MWPC modules arranged to form the lateral surface of a hexagonal prism. Each module (50 x 50 sq cm) has a 2 cm thick lead-glass tube converter on both sides of a MWPC pressurized to 2 atm. Experimental measurements are presented to show how to reduce the parallax error by determining in which of the two converter layers the photon has interacted. The results of a detailed Monte Carlo calculation for the efficiency of this type of converter are shown to be in excellent agreement with the experimental measurements. The expected performance of the Positron Camera is presented: a true coincidence rate of 56,000 counts/s (with an equal accidental coincidence rate and a 30% Compton scatter contamination) and a spatial resolution better than 5.0 mm (FWHM) for a 400 micron Ci pointlike source embedded in a 10 cm radius water phantom.

  14. Spatial resolution of the electrical conductance of ionic fluids using a Green-Kubo method.

    PubMed

    Jones, R E; Ward, D K; Templeton, J A

    2014-11-14

    We present a Green-Kubo method to spatially resolve transport coefficients in compositionally heterogeneous mixtures. We develop the underlying theory based on well-known results from mixture theory, Irving-Kirkwood field estimation, and linear response theory. Then, using standard molecular dynamics techniques, we apply the methodology to representative systems. With a homogeneous salt water system, where the expectation of the distribution of conductivity is clear, we demonstrate the sensitivities of the method to system size, and other physical and algorithmic parameters. Then we present a simple model of an electrochemical double layer where we explore the resolution limit of the method. In this system, we observe significant anisotropy in the wall-normal vs. transverse ionic conductances, as well as near wall effects. Finally, we discuss extensions and applications to more realistic systems such as batteries where detailed understanding of the transport properties in the vicinity of the electrodes is of technological importance.

  15. The plasma and magnetic field properties of coronal loops observed at high spatial resolution

    NASA Technical Reports Server (NTRS)

    Webb, D. F.; Holman, G. D.; Davis, J. M.; Kundu, M. R.; Shevgaonkar, R. K.

    1987-01-01

    Two data sets are analyzed in order to improve understanding of the plasma and magnetic field properties of active region coronal loops. Each set consists of coaligned, high spatial resolution soft X-ray, microwave, and magnetogram images that are used to compare observations of coronal loops and their feet in the photosphere and to constrain possible microwave emission mechanisms. The loops are found to have plasma parameters typical of quiescent active region loops. Each loop has a compact microwave source with peak brightness temperature T(b) = 1-2.5 x 10 to the 6th K cospatial with or near the loop apex. No complete loops are imaged in microwaves. The loop emission observed at 4.9 GHz is best described by fourth harmonic gyroresonance emission from a dipole loop model, but with less field variation along the loop than in the models of Holman and Kundu (1985).

  16. Improved mid infrared detector for high spectral or spatial resolution and synchrotron radiation use

    NASA Astrophysics Data System (ADS)

    Faye, Mbaye; Bordessoule, Michel; Kanouté, Brahim; Brubach, Jean-Blaise; Roy, Pascale; Manceron, Laurent

    2016-06-01

    When using bright, small effective size sources, such as synchrotron radiation light beam, for broadband spectroscopy at spectral or spatial high resolution for mid-IR FTIR measurements, a marked detectivity improvement can be achieved by setting up a device matching the detector optical étendue to that of the source. Further improvement can be achieved by reducing the background unmodulated flux and other intrinsic noise sources using a lower temperature cryogen, such as liquid helium. By the combined use of cooled apertures, cold reimaging optics, filters and adapted detector polarization, and preamplification electronics, the sensitivity of a HgCdTe photoconductive IR detector can be improved by a significant factor with respect to standard commercial devices (more than one order of magnitude on average over 6-20 μm region) and the usable spectral range extended to longer wavelengths. The performances of such an optimized detector developed on the AILES Beamline at SOLEIL are presented here.

  17. Subsurface imaging of silicon nanowire circuits and iron oxide nanoparticles with sub-10 nm spatial resolution.

    PubMed

    Perrino, A P; Ryu, Y K; Amo, C A; Morales, M P; Garcia, R

    2016-07-01

    Non-destructive subsurface characterization of nanoscale structures and devices is of significant interest in nanolithography and nanomanufacturing. In those areas, the accurate location of the buried structures and their nanomechanical properties are relevant for optimization of the nanofabrication process and the functionality of the system. Here we demonstrate the capabilities of bimodal and trimodal force microscopy for imaging silicon nanowire devices buried under an ultrathin polymer film. We resolve the morphology and periodicities of silicon nanowire pairs. We report a spatial resolution in the sub-10 nm range for nanostructures buried under a 70 nm thick polymer film. By using numerical simulations we explain the role of the excited modes in the subsurface imaging process. Independent of the bimodal or trimodal atomic force microscopy approach, the fundamental mode is the most suitable for tracking the topography while the higher modes modulate the interaction of the tip with the buried nanostructures and provide subsurface contrast.

  18. Investigations on the spatial resolution of autocollimator-based slope measuring profilers

    NASA Astrophysics Data System (ADS)

    Siewert, F.; Buchheim, J.; Höft, T.; Zeschke, T.; Schindler, A.; Arnold, T.

    2013-05-01

    During the last decade, autocollimator-based slope measuring profilers like the Nanometer Optical Component Measuring Machine (NOM) at BESSY-II have become standard instrument for the ultra-precise characterization of synchrotron optics with nanometer accuracy. Due to the increasing demand for highest accuracy, which can be provided by these profilers, further investigations are necessary to understand the performance of these instruments. Besides the achievable accuracy, it is of particular interest to characterize the possible spatial resolution of such instrumentation. The performance of the BESSY-NOM was characterized by means of sinusoidal and chirped surface profiles. A dedicated sample was prepared using the Atmospheric Plasma Jet Machining technology at the IOM—Leibniz-Institut für Oberflächenmodifizierung e.V. We report on our tests on the NOM, the interferometer measurements done for comparison as well as the sample preparation.

  19. Improved mid infrared detector for high spectral or spatial resolution and synchrotron radiation use.

    PubMed

    Faye, Mbaye; Bordessoule, Michel; Kanouté, Brahim; Brubach, Jean-Blaise; Roy, Pascale; Manceron, Laurent

    2016-06-01

    When using bright, small effective size sources, such as synchrotron radiation light beam, for broadband spectroscopy at spectral or spatial high resolution for mid-IR FTIR measurements, a marked detectivity improvement can be achieved by setting up a device matching the detector optical étendue to that of the source. Further improvement can be achieved by reducing the background unmodulated flux and other intrinsic noise sources using a lower temperature cryogen, such as liquid helium. By the combined use of cooled apertures, cold reimaging optics, filters and adapted detector polarization, and preamplification electronics, the sensitivity of a HgCdTe photoconductive IR detector can be improved by a significant factor with respect to standard commercial devices (more than one order of magnitude on average over 6-20 μm region) and the usable spectral range extended to longer wavelengths. The performances of such an optimized detector developed on the AILES Beamline at SOLEIL are presented here. PMID:27370438

  20. Local rank-based spatial information for improvement of remote sensing hyperspectral imaging resolution.

    PubMed

    Zhang, Xin; Juan, Anna de; Tauler, Romà

    2016-01-01

    This paper shows the effect of using local rank and selectivity constraints based on spatial information of spectroscopic images to increase the performance of Multivariate Curve Resolution (MCR) methods and to decrease the ambiguity of final results. Fixed Size Image Window-Evolving Factor Analysis (FSIW-EFA) is applied to discover which pixels are more suitable for the application of local rank constraints. An automated method to help in setting appropriate threshold values for the application of FSIW-EFA, based on global and local use of Singular Value Decomposition (SVD) is proposed. Additional use of correlation coefficients between selected reference spectra and pixel spectra of the image is shown to provide an alternative way for the application of the selectivity constraint in spectroscopic images for the first time. This alternative method resulted to be satisfactory when pure pixels exist. PMID:26695226

  1. Subsurface imaging of silicon nanowire circuits and iron oxide nanoparticles with sub-10 nm spatial resolution

    NASA Astrophysics Data System (ADS)

    Perrino, A. P.; Ryu, Y. K.; Amo, C. A.; Morales, M. P.; Garcia, R.

    2016-07-01

    Non-destructive subsurface characterization of nanoscale structures and devices is of significant interest in nanolithography and nanomanufacturing. In those areas, the accurate location of the buried structures and their nanomechanical properties are relevant for optimization of the nanofabrication process and the functionality of the system. Here we demonstrate the capabilities of bimodal and trimodal force microscopy for imaging silicon nanowire devices buried under an ultrathin polymer film. We resolve the morphology and periodicities of silicon nanowire pairs. We report a spatial resolution in the sub-10 nm range for nanostructures buried under a 70 nm thick polymer film. By using numerical simulations we explain the role of the excited modes in the subsurface imaging process. Independent of the bimodal or trimodal atomic force microscopy approach, the fundamental mode is the most suitable for tracking the topography while the higher modes modulate the interaction of the tip with the buried nanostructures and provide subsurface contrast.

  2. High spatial resolution, low-noise Brillouin dynamic gratings reflectometry based on digital pulse compression.

    PubMed

    Bergman, A; Langer, T; Tur, M

    2016-08-01

    Digital pulse compression was used to enhance the performance of optical time-domain reflectometry, employing Brillouin dynamic gratings (BDGs) in polarization-maintaining fibers. The fundamental and unique issues in BDG field-reflection are addressed, and rules for proper selection of the coding and detection techniques are formulated. While coding in BDG applications generally requires coherent processing of the reflection, conditions are established for use of direct detection. A 256-bit Golay complementary unipolar probe code is used to demonstrate an eightfold signal-to-noise ratio enhancement in the measurement of the Brillouin gain spectrum (BGS), with a spatial resolution of 2 cm and a full-BGS acquisition rate of 133⅓ kHz, resulting in an equivalent reduction in the estimation error of small Brillouin frequency shifts. PMID:27472639

  3. Vegetation index correction to reduce background effects in orchards with high spatial resolution imagery

    NASA Astrophysics Data System (ADS)

    Van Beek, Jonathan; Tits, Laurent; Somers, Ben; Deckers, Tom; Janssens, Pieter; Coppin, Pol

    2014-10-01

    High spatial resolution satellite imagery provides an alternative for time consuming and labor intensive in situ measurements of biophysical variables, such as chlorophyll and water content. However, despite the high spatial resolution of current satellite sensors, mixtures of canopies and backgrounds will be present, hampering the estimation of biophysical variables. Traditional correction methodologies use spectral differences between canopies and backgrounds, but fail with spectrally similar canopies and backgrounds. In this study, the lack of a generic solution to reduce background effects is tackled. Through synthetic imagery, the mixture problem was demonstrated with regards to the estimation of biophysical variables. A correction method was proposed, rescaling vegetation indices based on the canopy cover fraction. Furthermore, the proposed method was compared to traditional background correction methodologies (i.e. soil-adjusted vegetation indices and signal unmixing) for different background scenarios. The results of a soil background scenario showed the inability of soil-adjusted vegetation indices to reduce background admixture effects, while signal unmixing and the proposed method removed background influences for chlorophyll (ΔR2 = ~0.3; ΔRMSE = ~1.6 μg/cm2) and water (ΔR2 = ~0.3; ΔRMSE = ~0.5 mg/cm2) related vegetation indices. For the weed background scenario, signal unmixing was unable to remove the background influences for chlorophyll content (ΔR2 = -0.1; ΔRMSE = -0.6 μg/cm 2 ), while the proposed correction method reduced background effects (ΔR2= 0.1; ΔRMSE = 0.4 μg/cm2). Overall, the proposed vegetation index correction method reduced the background influence irrespective of background type, making useful comparison between management blocks possible.

  4. Predicting Real-Time Soil Carbon Fluxes in Alaska at High Spatial Resolution

    NASA Astrophysics Data System (ADS)

    Pan, J.; Stieglitz, M.; Cheng, Y.; Pan, F.

    2013-12-01

    In this study we employ 3 full years (2009 - 2011) of high spatial resolution (7.5 km) hourly snapshots of snow depth and air temperatures throughout Alaska from Weather Underground (WU). We do so in order to demonstrate the practicalities of using real-time weather data to predict soil CO2 fluxes over large areas. As a preliminary step, hourly snow depth and air temperatures reported from WU were compared with observations from SNOTEL stations. WU reported hourly-daily air temperatures were consistent with observations. Likewise, snow depth in the interior of Alaska and on the North Slope matched observations well. In the Southeast coastal areas, WU reported snow depth were consistently low. We then used a simple empirical ground temperature scheme (Cheng et al., 2010) along with snow depth and air temperatures reported from WU to predict soil temperatures. Using these generated soil temperatures, as well as antecedent precipitation, a simple soil decomposition model was then calibrated with biophysical data from Barrow and Toolik Lake, Alaska. Post-calibration, model parameters were kept fixed and the model was run over the full hourly 2009 - 2011 record for the over 700 stations where we have measured soil carbon profiles. To test robustness, the model was calibrated independently at all location where we have good biophysical information and subsequently run over the remaining stations. These simulations demonstrate the degree to which real-time weather data can be trusted to provide an accurate high spatial resolution picture of daily, monthly, and seasonal soil C fluxes at high latitudes.

  5. High Spectral and Spatial Resolution Observations of Mars in 1999 and 2001

    NASA Astrophysics Data System (ADS)

    Simrell, E. R.; Chanover, N. J.; Murphy, J.; Beebe, R. F.; Hillman, J. J.; Glenar, D. A.; Kervin, P.; Africano, J. L.; Roberts, L., Jr.

    2001-12-01

    Visible and near-IR imaging observations of Mars were made during the 1999 and 2001 apparitions using high spectral and spatial resolution techniques that employ acousto-optic tuning and adaptive optics. The 1999 images were taken at the Apache Point Observatory 3.5 meter telescope using a near-infrared acousto-optic tunable filter (AOTF) camera, which operated between 1.6 and 3.6 microns. This enabled us to acquire ``spectral image cubes'' (x,y images with wavelength as the z-dimension) across the H and K bands on 24-25 April 1999. We analyzed the disk-integrated brightness across the H and K bands in an effort to identify atmospheric and/or surface absorption bands of CO2 and H2O. The AOTF data are examined to determine the optimal spectral resolution for spatially resolved images of Mars. The 2001 data were acquired between 18 March and 08 July 2001 in a service observing mode at the Air Force Advanced Electro-Optical System (AEOS) 3.6 meter telescope. This telescope is equipped with an adaptive optics (AO) system, and we utilized the facility AO science camera with several broad-band filters in the red/near-IR. These data are used for the characterization of several narrow-band filters that will be purchased for the AO system. Surface features in this data set are compared to those seen in recent Hubble Space Telescope imagery of Mars in a comparison of ground-based adaptive optics vs. spacecraft imaging techniques. Observations made at the Maui Space Surveillance System (MSSS), Maui, Hawaii, USA, were made as part of a collaboration between New Mexico State University and Detachment 15 of the US Air Force Research Laboratory's Directed Energy Directorate, which owns and operates the MSSS.

  6. Influence of Spatial Resolution on SiC Industrial Foam's Structural Parameters Obtained by X-ray Microtomography

    NASA Astrophysics Data System (ADS)

    Nagata, Rodrigo; Appoloni, Carlos R.; Marques, Leonardo C.; Fernandes, Jaquiel S.

    2011-08-01

    X-rays microtomography is a non-destructive technique that generates digital images of samples' internal structure by attenuation of an X-rays beam. The samples' structural parameters are obtained from these images by specific software analysis. This means that the image quality is essential to perform a suitable structural characterization. The spatial resolution is one of the main parameters that contribute to image quality. In this work the influence of spatial resolution for industrial SiC ceramic foam's analysis was evaluated. The samples' pore density was 60 pores per inch (ppi). This kind of foam can operate at high temperatures, which allow them to be used as liquid metal filters, heat exchangers or composite of rocket nozzles, for example. The measurements were performed with a SkyScan microtomograph, model 1172. It was operated at 50 kV and 60 kV high voltage for measurements with 24.8 μm and 2.5 μm spatial resolution, respectively. The total porosity and the pore size distribution were the structural parameters studied. They were obtained by Imago software. The total porosity results were statistically equivalent for both resolutions, but the comparison of the microtomographic images datasets and pore size distributions of both resolutions showed differences that enhances the importance of the spatial resolution for a complete characterization of the sample internal microstructure.

  7. High spatial resolution Hall sensor array for edge plasma magnetic field measurements

    SciTech Connect

    Liu Yuhong; Maurer, David A.; Navratil, Gerald A.; Rivera, Nicholas

    2005-09-15

    A one-dimensional, high-spatial resolution, 20-element Hall sensor array has been developed to directly measure the edge plasma perpendicular magnetic field and its fluctuations as a function of radius with 4-mm resolution. The array employs new small-area, high-sensitivity indium antimonide (InSb) Hall probes in combination with a high-density seven-layer printed circuit board to provide for connections to supply Hall current, record the measured Hall voltage output signals, and mitigate inductive pickup. A combination of bench and in situ measurements is described that provides absolute calibration of the diagnostic array in the presence of a strong transverse magnetic field component that is approximately 1000 times greater than the perpendicular fluctuating field needed to be resolved by the diagnostic. The Hall probes calibrated using this method are capable of magnetic field measurements with a sensitivity of 7 V/T over the frequency band from 0 to 20 kHz.

  8. High spatial resolution Hall sensor array for edge plasma magnetic field measurements

    NASA Astrophysics Data System (ADS)

    Liu, Yuhong; Maurer, David A.; Navratil, Gerald A.; Rivera, Nicholas

    2005-09-01

    A one-dimensional, high-spatial resolution, 20-element Hall sensor array has been developed to directly measure the edge plasma perpendicular magnetic field and its fluctuations as a function of radius with 4-mm resolution. The array employs new small-area, high-sensitivity indium antimonide (InSb) Hall probes in combination with a high-density seven-layer printed circuit board to provide for connections to supply Hall current, record the measured Hall voltage output signals, and mitigate inductive pickup. A combination of bench and in situ measurements is described that provides absolute calibration of the diagnostic array in the presence of a strong transverse magnetic field component that is approximately 1000 times greater than the perpendicular fluctuating field needed to be resolved by the diagnostic. The Hall probes calibrated using this method are capable of magnetic field measurements with a sensitivity of 7V/T over the frequency band from 0 to 20 kHz.

  9. Optical and radar analysis of auroral curls at high spatial resolution

    NASA Astrophysics Data System (ADS)

    Dahlgren, Hanna; Kaila, Kari; Ivchenko, Nickolay; Lanchester, Betty; Whiter, Daniel; Marklund, Göran; Aikio, Anita

    Auroral arcs can develop small-scale distortions known as vortex streets or curls. Optical ground-based observations of this phenomenon have indicated that curls are often associated with shear flows. For a comprehensive analysis of the temporal and spatial characteristics associated with the formation and evolution of curls, high resolution optical measurements are required. We report here on an event study of an arc evolving into curls and associated with counter-streaming structures, observed on 23 November 2006 by ground-based optical instrumentation and measured by the European Incoherent Scatter Radar (EISCAT) located outside Tromso, Norway. The optical Instrumentation consisted of three, narrow field-of-view (3 deg x 3 deg) imagers (Auroral Structure and Kinetics), each equipped with different passband filters, together with a white light video camera (FOV: 45 deg x 60 deg, 25 Hz) providing the large-scale context of the event. The temporal evolution of the smallest structures was recorded at a time resolution of 20 Hz. Shear velocities between the center and the edge of the arc are investigated, and the origin and evolution of the observed small-scale auroral features are discussed in the light of existing theories.

  10. Atmospheric Correction of High-Spatial-Resolution Commercial Satellite Imagery Products Using MODIS Atmospheric Products

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Holekamp, Kara; Ryan, Robert E.; Vaughan, Ronald; Russell, Jeffrey A.; Prados, Don; Stanley, Thomas

    2005-01-01

    Remotely sensed ground reflectance is the basis for many inter-sensor interoperability or change detection techniques. Satellite inter-comparisons and accurate vegetation indices such as the Normalized Difference Vegetation Index, which is used to describe or to imply a wide variety of biophysical parameters and is defined in terms of near-infrared and redband reflectance, require the generation of accurate reflectance maps. This generation relies upon the removal of solar illumination, satellite geometry, and atmospheric effects and is generally referred to as atmospheric correction. Atmospheric correction of remotely sensed imagery to ground reflectance, however, has been widely applied to only a few systems. In this study, we atmospherically corrected commercially available, high spatial resolution IKONOS and QuickBird imagery using several methods to determine the accuracy of the resulting reflectance maps. We used extensive ground measurement datasets for nine IKONOS and QuickBird scenes acquired over a two-year period to establish reflectance map accuracies. A correction approach using atmospheric products derived from Moderate Resolution Imaging Spectrometer data created excellent reflectance maps and demonstrated a reliable, effective method for reflectance map generation.

  11. Atmospheric Correction of High-Spatial-Resolution Commercial Satellite Imagery Products Using MODIS Atmospheric Products

    NASA Technical Reports Server (NTRS)

    Pagnutti, Mary; Holekamp, Kara; Ryan, Robert E.; Vaughan, Ronand; Russell, Jeff; Prados, Don; Stanley, Thomas

    2005-01-01

    Remotely sensed ground reflectance is the foundation of any interoperability or change detection technique. Satellite intercomparisons and accurate vegetation indices, such as the Normalized Difference Vegetation Index (NDVI), require the generation of accurate reflectance maps (NDVI is used to describe or infer a wide variety of biophysical parameters and is defined in terms of near-infrared (NIR) and red band reflectances). Accurate reflectance-map generation from satellite imagery relies on the removal of solar and satellite geometry and of atmospheric effects and is generally referred to as atmospheric correction. Atmospheric correction of remotely sensed imagery to ground reflectance has been widely applied to a few systems only. The ability to obtain atmospherically corrected imagery and products from various satellites is essential to enable widescale use of remotely sensed, multitemporal imagery for a variety of applications. An atmospheric correction approach derived from the Moderate Resolution Imaging Spectroradiometer (MODIS) that can be applied to high-spatial-resolution satellite imagery under many conditions was evaluated to demonstrate a reliable, effective reflectance map generation method. Additional information is included in the original extended abstract.

  12. Improved Spatial Resolution in Thick, Fully-Depleted CCDs withEnhanced Red Sensitivity

    SciTech Connect

    Fairfield, Jessamyn A.; Groom, Donald E.; Bailey, Stephen J.; Bebek, Christopher J.; Holland, Stephen E.; Karcher, Armin; Kolbe,William F.; Lorenzon, Wolfgang; Roe, Natalie A.

    2006-03-09

    The point spread function (PSF) is an important measure of spatial resolution in CCDs for point-like objects, since it affects image quality and spectroscopic resolution. We present new data and theoretical developments for lateral charge diffusion in thick, fully-depleted charge-coupled devices (CCDs) developed at Lawrence Berkeley National Laboratory (LBNL). Because they can be over-depleted, the LBNL devices have no field-free region and diffusion is controlled through the application of an external bias voltage. We give results for a 3512 x 3512 format, 10.5 {micro}m pixel back-illuminated p-channel CCD developed for the SuperNova/Acceleration Probe (SNAP), a proposed satellite-based experiment designed to study dark energy. The PSF was measured at substrate bias voltages between 3 V and 115 V. At a bias voltage of 115 V, we measure an rms diffusion of 3.7 {+-} 0.2 {micro}m. Lateral charge diffusion in LBNL CCDs will meet the SNAP requirements.

  13. Optophysiological Approach to Resolve Neuronal Action Potentials with High Spatial and Temporal Resolution in Cultured Neurons

    PubMed Central

    Pagès, Stéphane; Côté, Daniel; De Koninck, Paul

    2011-01-01

    Cell to cell communication in the central nervous system is encoded into transient and local membrane potential changes (ΔVm). Deciphering the rules that govern synaptic transmission and plasticity entails to be able to perform Vm recordings throughout the entire neuronal arborization. Classical electrophysiology is, in most cases, not able to do so within small and fragile neuronal subcompartments. Thus, optical techniques based on the use of fluorescent voltage-sensitive dyes (VSDs) have been developed. However, reporting spontaneous or small ΔVm from neuronal ramifications has been challenging, in part due to the limited sensitivity and phototoxicity of VSD-based optical measurements. Here we demonstrate the use of water soluble VSD, ANNINE-6plus, with laser-scanning microscopy to optically record ΔVm in cultured neurons. We show that the sensitivity (>10% of fluorescence change for 100 mV depolarization) and time response (sub millisecond) of the dye allows the robust detection of action potentials (APs) even without averaging, allowing the measurement of spontaneous neuronal firing patterns. In addition, we show that back-propagating APs can be recorded, along distinct dendritic sites and within dendritic spines. Importantly, our approach does not induce any detectable phototoxic effect on cultured neurons. This optophysiological approach provides a simple, minimally invasive, and versatile optical method to measure electrical activity in cultured neurons with high temporal (ms) resolution and high spatial (μm) resolution. PMID:22016723

  14. Practical spatial resolution of electron energy loss spectroscopy in aberration corrected scanning transmission electron microscopy.

    PubMed

    Shah, A B; Ramasse, Q M; Wen, J G; Bhattacharya, A; Zuo, J M

    2011-08-01

    The resolution of electron energy loss spectroscopy (EELS) is limited by delocalization of inelastic electron scattering rather than probe size in an aberration corrected scanning transmission electron microscope (STEM). In this study, we present an experimental quantification of EELS spatial resolution using chemically modulated 2×(LaMnO(3))/2×(SrTiO(3)) and 2×(SrVO(3))/2×(SrTiO(3)) superlattices by measuring the full width at half maxima (FWHM) of integrated Ti M(2,3), Ti L(2,3), V L(2,3), Mn L(2,3), La N(4,5), La N(2,3) La M(4,5) and Sr L(3) edges over the superlattices. The EELS signals recorded using large collection angles are peaked at atomic columns. The FWHM of the EELS profile, obtained by curve-fitting, reveals a systematic trend with the energy loss for the Ti, V, and Mn edges. However, the experimental FWHM of the Sr and La edges deviates significantly from the observed experimental tendency.

  15. High Spatial Resolution Investigations of Microchannel Plate Imaging Properties for UV Detectors

    NASA Technical Reports Server (NTRS)

    Siegmund, Oswald

    1996-01-01

    Microchannel plate (MCP) photon counting detectors are currently being used with great success on many of the recent NASA/ESA ultraviolet (UV) astrophysics missions that make observations in the 1OO A - 1600 A range. These include HUT, the Wide Field Camera on ROSAT, EUVE, ALEXIS, ORFEUS, and SOHO. These devices have also been chosen to fly on future UV astrophysics missions such as FUSE, FUVITA, IMAGE, and both the HST STIS and Advanced Camera instruments. During the period of this award we have fabricated a dual-chamber vacuum test facility to carry out laboratory testing of detector resolution, image stability and linearity, and flat field performance to enable us to characterize the performance of MCPs and their associated read-out architectures. We have also fabricated and tested a laboratory 'test-bed' delay line detector, which can accommodate MCP's with a wide range of formats and run at high data rates, to continue our studies of MCP image fixed pattern noise, and particularly for new small pore MCP's which have recently come onto the market. These tests were mainly focussed on the assessment of cross delay-line (XDL) and double delay line (DDL) anode read-out schemes, with particular attention being focussed on flat-field and spatial resolution performance.

  16. High Resolution Spatial Analysis of Habitat Preference of Aedes Albopictus (Diptera: Culicidae) in an Urban Environment.

    PubMed

    Cianci, Daniela; Hartemink, Nienke; Zeimes, Caroline B; Vanwambeke, Sophie O; Ienco, Annamaria; Caputo, Beniamino

    2015-05-01

    Over the past decades, the Asian tiger mosquito (Aedes albopictus (Skuse, 1895)) has emerged in many countries, and it has colonized new environments, including urban areas. The species is a nuisance and a potential vector of several human pathogens, and a better understanding of the habitat preferences of the species is needed for help in successful prevention and control. So far, the habitat preference in urban environments has not been studied in Southern European cities. In this paper, spatial statistical models were used to evaluate the relationship between egg abundances and land cover types on the campus of Sapienza University in Rome, which is taken as an example of a European urban habitat. Predictor variables included land cover types, classified in detail on a high resolution image, as well as solar radiation and month of capture. The models account for repeated measures in the same trap and are adjusted for meteorological circumstances. Vegetation and solar radiation were found to be positively related to the number of eggs. More specifically, trees were positively related to the number of eggs and the relationship with grass was negative. These findings are consistent with the species' known preference for shaded areas. The unexpected positive relationship with solar radiation is amply discussed in the paper. This study represents a first step toward a better understanding of the spatial distribution of Ae. albopictus in urban environments. PMID:26334806

  17. High Spatial Resolution Studies of Blastwave Interactions in the Vela Supernova Remnant

    NASA Technical Reports Server (NTRS)

    Craig, William

    1997-01-01

    The report targeted two interaction zones within the Vela supernova remnant for HRI observation and data reduction and analysis. Approximately 40 ksec of HRI integration time was awarded for each of the awarded target regions, one at priority 2 and one at priority 3. The observations have been completed for the priority 2 observation. Some observations have been made of the priority 3 target, however the data have not yet been received by the PI. The priority 2 data have been received and analyzed and the results have been prepared for publication. The chief results are as follows: (1) the radial profile of the X-ray emission from the western rim is characterized by a sudden increase in emission at the blastwave interaction region which is unresolved spatially at HRI resolution. The profile is consistent with the expanding blastwave from the remnant encountering a large, coherent structure in the surrounding ISM; (2) the X-ray emission lags slightly 'behind', approx. 10(exp 16)cm the H(alpha) and OIII optical filaments, consistent with the expected spatial profile of the emission assuming parameters derived from earlier PSPC observations of the region. the combination of the X-ray and optical interference filter data allow us to set limits on the distance to the Vela remnant and the general nature of the blastwave interactions in the remnant.

  18. Annual evapotranspiration retrieved from satellite vegetation indices for the eastern Mediterranean at 250 m spatial resolution

    NASA Astrophysics Data System (ADS)

    Helman, D.; Givati, A.; Lensky, I. M.

    2015-11-01

    We present a model to retrieve actual evapotranspiration (ET) from satellites' vegetation indices (Parameterization of Vegetation Indices for ET estimation model, or PaVI-E) for the eastern Mediterranean (EM) at a spatial resolution of 250 m. The model is based on the empirical relationship between satellites' vegetation indices (normalized difference vegetation index (NDVI) and enhanced vegetation index (EVI) from MODIS) and total annual ET (ETAnnual) estimated at 16 FLUXNET sites, representing a wide range of plant functional types and ETAnnual. Empirical relationships were first examined separately for (a) annual vegetation systems (i.e. croplands and grasslands) and (b) systems with combined annual and perennial vegetation (i.e. woodlands, forests, savannah and shrublands). Vegetation indices explained most of the variance in ETAnnual in those systems (71 % for annuals, and 88 % for combined annual and perennial systems), while adding land surface temperature data in a multiple-variable regression and a modified version of the Temperature and Greenness model did not result in better correlations (p > 0.1). After establishing empirical relationships, PaVI-E was used to retrieve ETAnnual for the EM from 2000 to 2014. Models' estimates were highly correlated (R = 0.92, p < 0.01) with ETAnnual calculated from water catchment balances along rainfall gradient of the EM. They were also comparable to the coarser-resolution ET products of the Land Surface Analysis Satellite Applications Facility (LSA-SAF MSG ETa, 3.1 km) and MODIS (MOD16, 1 km) at 148 EM basins with R of 0.75 and 0.77 and relative biases of 5.2 and -5.2 %, respectively (p < 0.001 for both). In the absence of high-resolution (< 1 km) ET models for the EM the proposed model is expected to contribute to the hydrological study of this region, assisting in water resource management, which is one of the most valuable resources of this region.

  19. Spatially explicit rangeland erosion monitoring using high-resolution digital aerial imagery

    USGS Publications Warehouse

    Gillan, Jeffrey K.; Karl, Jason W.; Barger, Nichole N.; Elaksher, Ahmed; Duniway, Michael C.

    2016-01-01

    Nearly all of the ecosystem services supported by rangelands, including production of livestock forage, carbon sequestration, and provisioning of clean water, are negatively impacted by soil erosion. Accordingly, monitoring the severity, spatial extent, and rate of soil erosion is essential for long-term sustainable management. Traditional field-based methods of monitoring erosion (sediment traps, erosion pins, and bridges) can be labor intensive and therefore are generally limited in spatial intensity and/or extent. There is a growing effort to monitor natural resources at broad scales, which is driving the need for new soil erosion monitoring tools. One remote-sensing technique that can be used to monitor soil movement is a time series of digital elevation models (DEMs) created using aerial photogrammetry methods. By geographically coregistering the DEMs and subtracting one surface from the other, an estimate of soil elevation change can be created. Such analysis enables spatially explicit quantification and visualization of net soil movement including erosion, deposition, and redistribution. We constructed DEMs (12-cm ground sampling distance) on the basis of aerial photography immediately before and 1 year after a vegetation removal treatment on a 31-ha Piñon-Juniper woodland in southeastern Utah to evaluate the use of aerial photography in detecting soil surface change. On average, we were able to detect surface elevation change of ± 8−9cm and greater, which was sufficient for the large amount of soil movement exhibited on the study area. Detecting more subtle soil erosion could be achieved using the same technique with higher-resolution imagery from lower-flying aircraft such as unmanned aerial vehicles. DEM differencing and process-focused field methods provided complementary information and a more complete assessment of soil loss and movement than any single technique alone. Photogrammetric DEM differencing could be used as a technique to

  20. A Fluctuation Analysis of the Bolocam 1.1 mm Lockman Hole Survey

    NASA Astrophysics Data System (ADS)

    Maloney, Philip R.; Glenn, Jason; Aguirre, James E.; Golwala, Sunil R.; Laurent, G. T.; Ade, P. A. R.; Bock, J. J.; Edgington, S. F.; Goldin, A.; Haig, D.; Lange, A. E.; Mauskopf, P. D.; Nguyen, H.; Rossinot, P.; Sayers, J.; Stover, P.

    2005-12-01

    We perform a fluctuation analysis of the 1.1 mm Bolocam Lockman Hole Survey, which covers 324 arcmin2 to a very uniform point-source-filtered rms noise level of σ~=1.4 mJy beam-1. The fluctuation analysis has the significant advantage of using all of the available data, since no extraction of sources is performed: direct comparison is made between the observed pixel flux density distribution [P(D)] and the theoretical distributions for a broad range of power-law number count models, n(S)=n0S-δ. We constrain the number counts in the 1-10 mJy range and derive significantly tighter constraints than in previous work: the power-law index δ=2.7+0.18-0.15, while the amplitude is n0=1595+85-238 mJy-1 deg-2, or N(>1 mJy)=940+50-140 deg-2 (95% confidence). At flux densities above 4 mJy, where a valid comparison can be made, our results agree extremely well with those derived from the extracted source number counts by Laurent et al.: the best-fitting differential slope is somewhat shallower (δ=2.7 vs. 3.2), but well within the 68% confidence limit, and the amplitudes (number of sources per square degree) agree to 10%. At 1 mJy, however [the limit of the P(D) analysis], the shallower slope derived here implies a substantially smaller amplitude for the integral number counts than extrapolation from above 4 mJy would predict. Our derived normalization is about 2.5 times smaller than that determined by the Max-Planck Millimeter Bolometer (MAMBO) at 1.2 mm (Greve et al.). However, the uncertainty in the normalization for both data sets is dominated by the systematic (i.e., absolute flux calibration) rather than statistical errors; within these uncertainties, our results are in agreement. Our best-fit amplitude at 1 mJy is also about a factor of 3 below the prediction of Blain et al., but we are in agreement above a few millijanskys. We estimate that about 7% of the 1.1 mm background has been resolved at 1 mJy.

  1. The influence of spatial resolution on human health risk co-benefit estimates for global climate policy assessments.

    PubMed

    Shih, Hsiu-Ching; Crawford-Brown, Douglas; Ma, Hwong-wen

    2015-03-15

    Assessment of the ability of climate policies to produce desired improvements in public health through co-benefits of air pollution reduction can consume resources in both time and research funds. These resources increase significantly as the spatial resolution of models increases. In addition, the level of spatial detail available in macroeconomic models at the heart of climate policy assessments is much lower than that available in traditional human health risk modeling. It is therefore important to determine whether increasing spatial resolution considerably affects risk-based decisions; which kinds of decisions might be affected; and under what conditions they will be affected. Human health risk co-benefits from carbon emissions reductions that bring about concurrent reductions in Particulate Matter (PM10) emissions is therefore examined here at four levels of spatial resolution (Uniform Nation, Uniform Region, Uniform County/city, Health Risk Assessment) in a case study of Taiwan as one of the geographic regions of a global macroeceonomic model, with results that are representative of small, industrialized nations within that global model. A metric of human health risk mortality (YOLL, years of life lost in life expectancy) is compared under assessments ranging from a "uniform simulation" in which there is no spatial resolution of changes in ambient air concentration under a policy to a "highly spatially resolved simulation" (called here Health Risk Assessment). PM10 is chosen in this study as the indicator of air pollution for which risks are assessed due to its significance as a co-benefit of carbon emissions reductions within climate mitigation policy. For the policy examined, the four estimates of mortality in the entirety of Taiwan are 747 YOLL, 834 YOLL, 984 YOLL and 916 YOLL, under Uniform Taiwan, Uniform Region, Uniform County and Health Risk Assessment respectively; or differences of 18%, 9%, 7% if the HRA methodology is taken as the baseline. While

  2. The influence of spatial resolution on human health risk co-benefit estimates for global climate policy assessments.

    PubMed

    Shih, Hsiu-Ching; Crawford-Brown, Douglas; Ma, Hwong-wen

    2015-03-15

    Assessment of the ability of climate policies to produce desired improvements in public health through co-benefits of air pollution reduction can consume resources in both time and research funds. These resources increase significantly as the spatial resolution of models increases. In addition, the level of spatial detail available in macroeconomic models at the heart of climate policy assessments is much lower than that available in traditional human health risk modeling. It is therefore important to determine whether increasing spatial resolution considerably affects risk-based decisions; which kinds of decisions might be affected; and under what conditions they will be affected. Human health risk co-benefits from carbon emissions reductions that bring about concurrent reductions in Particulate Matter (PM10) emissions is therefore examined here at four levels of spatial resolution (Uniform Nation, Uniform Region, Uniform County/city, Health Risk Assessment) in a case study of Taiwan as one of the geographic regions of a global macroeceonomic model, with results that are representative of small, industrialized nations within that global model. A metric of human health risk mortality (YOLL, years of life lost in life expectancy) is compared under assessments ranging from a "uniform simulation" in which there is no spatial resolution of changes in ambient air concentration under a policy to a "highly spatially resolved simulation" (called here Health Risk Assessment). PM10 is chosen in this study as the indicator of air pollution for which risks are assessed due to its significance as a co-benefit of carbon emissions reductions within climate mitigation policy. For the policy examined, the four estimates of mortality in the entirety of Taiwan are 747 YOLL, 834 YOLL, 984 YOLL and 916 YOLL, under Uniform Taiwan, Uniform Region, Uniform County and Health Risk Assessment respectively; or differences of 18%, 9%, 7% if the HRA methodology is taken as the baseline. While

  3. Modelling the archaeomagnetic field under spatial constraints from dynamo simulations: a resolution analysis

    NASA Astrophysics Data System (ADS)

    Sanchez, S.; Fournier, A.; Aubert, J.; Cosme, E.; Gallet, Y.

    2016-11-01

    Archaeomagnetic observations are key to recovering the behaviour of the geomagnetic field over the past few millennia. The corresponding data set presents a highly heterogeneous distribution in both space and time. Furthermore, the data are affected by substantial age and experimental uncertainties. In order to mitigate these detrimental properties, time-dependent global archaeomagnetic field models are usually constructed under spatial and temporal regularization constraints, with the use of bootstrap techniques to account for data uncertainties. The models so obtained are the product of an adjustable trade-off between goodness-of-fit and model complexity. The spatial complexity is penalized by means of a norm reflecting the minimization of Ohmic dissipation within the core. We propose in this study to resort to alternative spatial constraints relying on the statistics of a numerical dynamo simulation with Earth-like features. To that end, we introduce a dynamo norm in an ensemble least-squares iterative framework, the goal of which is to produce single-epoch models of the archaeomagnetic field. We first validate this approach using synthetic data. We next construct a redistributed archaeomagnetic data set between 1200 BC and 2000 AD by binning the data in windows of 40-yr width. Since the dynamo norm is not adjustable, we can legitimately calculate a resolution matrix to quantify the resolving power of the available archaeomagnetic data set. Gauss coefficients are resolved up to spherical harmonic degree 3 for the first thousand years of the interval, to degree 4 for the next thousand years and to degree 5 during the last millennium. These conclusions are based on the distribution and uncertainties that characterize the data set, and do not take into account the possible presence of outliers. Comparison between our model, called AmR, and previously published archaeomagnetic field models confirms the archaeomagnetic resolution analysis: it highlights the dichotomy

  4. Sunglint effects on the characterization of optically active substances in high spatial resolution airborne hyperspectral images

    NASA Astrophysics Data System (ADS)

    Streher, A. S.; Faria Barbosa, C. Clemente; Soares Galvão, L.; Goodman, J. A.; Silva, T. S.

    2013-05-01

    Sunglint, also known as the specular reflection of light from water surfaces, is a component of sensor-received radiance that represents a confounding factor on the characterization of water bodies by remote sensing. In airborne remote sensing images, the effect of sunglint can be minimized by optimizing the flight paths, directing the sensor towards or away from the Sun, and by keeping solar zenith angles between 30° and 60°. However, these guidelines cannot always be applied, often due to the irregular spatial pattern of lakes, estuaries and coastlines. The present study assessed the impact of sunglint on the relationship between the optically active substances (OAS) concentration, in optically complex waters, and the spectral information provided by an airborne high spatial resolution hyperspectral sensor (SpecTIR). The Ibitinga reservoir, located in southeastern Brazil (state of São Paulo), was selected as the study area because of its meandering shape. As a result, there is demanding constant changes in data acquisition geometry to achieve complete coverage, therefore not allowing sunglint conditions to be minimized during image acquisition. Field data collection was carried out on October 23 and 24, 2011. During these two days, 15 water stations along the reservoir were sampled, concurrently with the SpecTIR image acquisition in 357 bands (398-2455 nm) and at 3 m spatial resolution. Chlorophyll, pheophytin, total suspended solids, organic and inorganic suspended solids and colored dissolved matter were determined in laboratory. The images were corrected for the atmospheric effects using the Fast Line-of-sight Atmospheric Analysis of Spectral Hypercubes (FLAASH) algorithm and then geometrically corrected. In order to evaluate the sunglint effects on the OAS characterization, the images were corrected for such effects using the deglint algorithm from Goodman et al. (2008). The SpecTIR 662-nm band reflectance was selected to be correlated to the OAS due to

  5. High spatial and temporal resolution wide-field imaging of neuron activity using quantum NV-diamond

    PubMed Central

    Hall, L. T.; Beart, G. C. G.; Thomas, E. A.; Simpson, D. A.; McGuinness, L. P.; Cole, J. H.; Manton, J. H.; Scholten, R. E.; Jelezko, F.; Wrachtrup, Jörg; Petrou, S.; Hollenberg, L. C. L.

    2012-01-01

    A quantitative understanding of the dynamics of biological neural networks is fundamental to gaining insight into information processing in the brain. While techniques exist to measure spatial or temporal properties of these networks, it remains a significant challenge to resolve the neural dynamics with subcellular spatial resolution. In this work we consider a fundamentally new form of wide-field imaging for neuronal networks based on the nanoscale magnetic field sensing properties of optically active spins in a diamond substrate. We analyse the sensitivity of the system to the magnetic field generated by an axon transmembrane potential and confirm these predictions experimentally using electronically-generated neuron signals. By numerical simulation of the time dependent transmembrane potential of a morphologically reconstructed hippocampal CA1 pyramidal neuron, we show that the imaging system is capable of imaging planar neuron activity non-invasively at millisecond temporal resolution and micron spatial resolution over wide-fields. PMID:22574249

  6. Feasibility study of a high-spatial resolution x-ray computed tomography using sub-pixel shift method

    SciTech Connect

    Yoneyama, Akio Baba, Rika; Sumitani, Kazushi; Hirai, Yasuharu

    2015-02-23

    A high-spatial resolution X-ray computed tomography (CT) adopting a sub-pixel shift method has been developed. By calculating sectional images, using plural CT datasets obtained by scanning the X-ray imager, the spatial resolution can be reduced relative to the sub-pixel size of an X-ray imager. Feasibility observations of a biomedical sample were performed using 12-keV monochromatic synchrotron radiation and a photon-counting X-ray imager 174-μm pixels in size. Four CT measurements were performed to obtain datasets at different positions of the X-ray imager. Fine sectional images were obtained successfully, and the spatial resolution was estimated as 80-μm, which corresponds to just under half the pixel size of the imager. In addition, a fine 3D image was also obtained by scanning the imager two-dimensionally.

  7. High Spatial Resolution MRI of Cystic Adventitial Disease of the Iliofemoral Vein Communicating with the Hip Joint

    SciTech Connect

    Michaelides, Michael; Pantziara, Maria Ioannidis, Kleanthis

    2013-05-14

    Venous cystic adventitial disease (CAD) is an extremely rare entity, and so far less than 20 cases have been described in the literature. Herein, we describe the imaging findings of CAD of iliofemoral vein in a 51-year-old woman who presented with leg swelling with special emphasis on high spatial resolution MRI, which demonstrated communication of the cyst with the hip joint. To our knowledge, this is the first description of high spatial resolution MRI findings in venous CAD supporting a new theory about the pathogenesis of venous CAD.

  8. Combining Surface Treatments with Shallow Slots to Improve the Spatial Resolution Performance of Continuous, Thick LYSO Detectors for PET.

    PubMed

    Kaul, M; Surti, S; Karp, J S

    2013-02-01

    Positron emission tomography (PET) detectors based on continuous scintillation crystals can achieve very good performance and have a number of practical advantages compared to detectors based on a pixelated array of crystals. Our goal is to develop a thick continuous detector with high energy and spatial resolution, along with high γ-photon capture efficiency. We examine the performance of two crystal blocks: a 46 × 46 × 14 mm(3) and a 48 × 48 × 25 mm(3) block of LYSO (Lutetium Yttrium Orthosilicate). Using Maximum Likelihood (ML) positioning based upon the light response function (LRF) in the 14 mm thick crystal, we measure a spatial resolution of 3 mm in the central region of the crystal with degradation near the edges due to reflections off the crystal sides. We also show that we can match the spatial resolution achieved using a 14 mm thick crystal by using a 25 mm thick crystal with slots cut into the gamma entrance surface to narrow the LRF. We also find that we can improve the spatial resolution performance near the detector edges by reducing the reflectivity of the crystal sides, albeit with some loss in energy resolution. PMID:24077642

  9. New Lens-Free X-ray Source for Laboratory Nano-CT with 50-nm Spatial Resolution

    SciTech Connect

    Sasov, A.; Pauwels, B.; Bruyndonckx, P.; Liu, X.

    2011-09-09

    X-ray optics, such as zone plates, are often used to obtain a spatial resolution better than 100 nm in x-ray projection images. Such types of optics are not always suited for tomographic imaging due to their limited depth of focus, which restricts the size of the specimen to a few microns. To overcome these limitations, we developed a new lens-free setup for a nano-CT system. Spatial resolution of nano-CT systems is mainly defined by x-ray source performance. It is dependent on target shape and focusing of the electron beam. The typical way to improve spatial resolution is based on replacement of the bulk metal target to thin film. It allows getting submicron spot size, but significantly reduces x-ray flux. To overcome flux limitation without compromising with spatial resolution, we invented a new type of target shaped as a rod or needle towards the camera. It allows us to reach 50-nm resolution with reasonable flux.

  10. Analytic model for the spatial and spectral resolution of pixellated semiconducting detectors of high-energy photons

    SciTech Connect

    Kozorezov, A.G.; Wigmore, J.K.; Owens, A.; Hartog, R. den; Peacock, A.

    2005-04-01

    We report the development of a general analytic method for describing the responsivity and resolution for a pixellated semiconductor detector structure in terms of device and material properties. The method allows both drift and diffusive transport to be modelled, for which previously only Monte Carlo techniques have been available. We obtain a general solution, and show specific results for an array of square pixels, illustrating the device constraints required to optimize spatial and spectral resolution.

  11. Simultaneous multiview capture and fusion improves spatial resolution in wide-field and light-sheet microscopy

    PubMed Central

    Wu, Yicong; Chandris, Panagiotis; Winter, Peter W.; Kim, Edward Y.; Jaumouillé, Valentin; Kumar, Abhishek; Guo, Min; Leung, Jacqueline M.; Smith, Corey; Rey-Suarez, Ivan; Liu, Huafeng; Waterman, Clare M.; Ramamurthi, Kumaran S.; La Riviere, Patrick J.; Shroff, Hari

    2016-01-01

    Most fluorescence microscopes are inefficient, collecting only a small fraction of the emitted light at any instant. Besides wasting valuable signal, this inefficiency also reduces spatial resolution and causes imaging volumes to exhibit significant resolution anisotropy. We describe microscopic and computational techniques that address these problems by simultaneously capturing and subsequently fusing and deconvolving multiple specimen views. Unlike previous methods that serially capture multiple views, our approach improves spatial resolution without introducing any additional illumination dose or compromising temporal resolution relative to conventional imaging. When applying our methods to single-view wide-field or dual-view light-sheet microscopy, we achieve a twofold improvement in volumetric resolution (~235 nm × 235 nm × 340 nm) as demonstrated on a variety of samples including microtubules in Toxoplasma gondii, SpoVM in sporulating Bacillus subtilis, and multiple protein distributions and organelles in eukaryotic cells. In every case, spatial resolution is improved with no drawback by harnessing previously unused fluorescence. PMID:27761486

  12. Spatial and temporal resolutions of EEG: Is it really black and white? A scalp current density view

    PubMed Central

    Burle, Borís; Spieser, Laure; Roger, Clémence; Casini, Laurence; Hasbroucq, Thierry; Vidal, Franck

    2015-01-01

    Among the different brain imaging techniques, electroencephalography (EEG) is classically considered as having an excellent temporal resolution, but a poor spatial one. Here, we argue that the actual temporal resolution of conventional (scalp potentials) EEG is overestimated, and that volume conduction, the main cause of the poor spatial resolution of EEG, also distorts the recovered time course of the underlying sources at scalp level, and hence degrades the actual temporal resolution of EEG. While Current Source Density (CSD) estimates, through the Surface Laplacian (SL) computation, are well known to dramatically reduce volume conduction effects and hence improve EEG spatial resolution, its positive impact on EEG temporal resolution is much less recognized. In two simulation studies, we first show how volume conduction and reference electrodes distort the scalp potential time course, and how SL transform provides a much better spatio-temporal description. We then exemplify similar effects on two empirical datasets. We show how the time courses of the scalp potentials mis-estimate the latencies of the relevant brain events and that CSD provides a much richer, and much more accurate, view of the spatio-temporal dynamics of brain activity. PMID:25979156

  13. A spatial resolution threshold of land cover in estimating terrestrial carbon sequestration in four counties in Georgia and Alabama, USA

    USGS Publications Warehouse

    Zhao, S.Q.; Liu, S.; Li, Z.; Sohl, T.L.

    2010-01-01

    Changes in carbon density (i.e., carbon stock per unit area) and land cover greatly affect carbon sequestration. Previous studies have shown that land cover change detection strongly depends on spatial scale. However, the influence of the spatial resolution of land cover change information on the estimated terrestrial carbon sequestration is not known. Here, we quantified and evaluated the impact of land cover change databases at various spatial resolutions (250 m, 500 m, 1 km, 2 km, and 4 km) on the magnitude and spatial patterns of regional carbon sequestration in four counties in Georgia and Alabama using the General Ensemble biogeochemical Modeling System (GEMS). Results indicated a threshold of 1 km in the land cover change databases and in the estimated regional terrestrial carbon sequestration. Beyond this threshold, significant biases occurred in the estimation of terrestrial carbon sequestration, its interannual variability, and spatial patterns. In addition, the overriding impact of interannual climate variability on the temporal change of regional carbon sequestration was unrealistically overshadowed by the impact of land cover change beyond the threshold. The implications of these findings directly challenge current continental- to global-scale carbon modeling efforts relying on information at coarse spatial resolution without incorporating fine-scale land cover dynamics.

  14. High Spatial Resolution Isotopic Abundance Measurements by Secondary Ion Mass Spectrometry: Status and Prospects

    NASA Astrophysics Data System (ADS)

    McKeegan, K. D.

    2007-12-01

    Secondary Ion Mass Spectrometry, SIMS or ion microprobe analysis, has become an important tool for geochemistry because of its ability study the distributions of elemental and isotopic abundances in situ on polished samples with high (typically a few microns to sub-micron) spatial resolution. In addition, SIMS exhibits high sensitivity for a wide range of elements (H to Pu) so that isotope analyses can sometimes be performed for elements that comprise only trace quantities of some mineral phase (e.g., Pb in zircon) or on major and/or minor elements in very small samples (e.g., presolar dust grains). Offsetting these positive attributes are analytical difficulties due to the complexity of the sputtering source of analyte ions: (1) relatively efficient production of molecular ion species (especially from a complex matrix such as most natural minerals) that cause interferences at the same nominal mass as atomic ions of interest, and (2) quantitation problems caused by variations in the ionization efficiencies of different elements and/or isotopes depending upon the chemical state of the sample surface during sputtering--the so-called "matrix effects". Despite the availability of high mass resolution instruments (e.g., SHRIMP II/RG, CAMECA 1270/1280/NanoSIMS), the molecular ion interferences effectively limit the region of the mass table that can be investigated in most samples to isotope systems at Ni or lighter or at Os or heavier. The matrix effects and the sensitivity of instrumental mass discrimination to the physical state of the sample surface can hamper reproducibility and have contributed to a view that SIMS analyses, especially for so- called stable isotopes, are most appropriate for extraterrestrial samples which are often small, rare, and can exhibit large magnitude isotopic effects. Recent improvements in instrumentation and technique have extended the scope of SIMS isotopic analyses and applications now range from geochronology to paleoclimatology to

  15. Estimation of crops biomass and evapotranspiration from high spatial and temporal resolutions remote sensing data

    NASA Astrophysics Data System (ADS)

    Claverie, Martin; Demarez, Valérie; Duchemin, Benoît.; Ceschia, Eric; Hagolle, Olivier; Ducrot, Danielle; Keravec, Pascal; Beziat, Pierre; Dedieu, Pierre

    2010-05-01

    Carbon and water cycles are closely related to agricultural activities. Agriculture has been indeed identified by IPCC 2007 report as one of the options to sequester carbon in soil. Concerning the water resources, their consumptions by irrigated crops are called into question in view of demographic pressure. In the prospect of an assessment of carbon production and water consumption, the use of crop models at a regional scale is a challenging issue. The recent availability of high spatial resolution (10 m) optical sensors associated to high temporal resolution (1 day) such as FORMOSAT-2 and, in the future, Venµs and SENTINEL-2 will offer new perspectives for agricultural monitoring. In this context, the objective of this work is to show how multi-temporal satellite observations acquired at high spatial resolution are useful for a regional monitoring of following crops biophysical variables: leaf area index (LAI), aboveground biomass (AGB) and evapotranspiration (ET). This study focuses on three summer crops dominant in South-West of France: maize, sunflower and soybean. A unique images data set (82 FORMOSAT-2 images over four consecutive years, 2006-2009) was acquired for this project. The experimental data set includes LAI and AGB measurements over eight agricultural fields. Two fields were intensively monitored where ET flux were measured with a 30 minutes time step using eddy correlation methods. The modelisation approach is based on FAO-56 method coupled with a vegetation functioning model based on Monteith theory: the SAFY model [5]. The model operates at a daily time step model to provide estimates of plant characteristics (LAI, AGB), soil conditions (soil water content) and water use (ET). As a key linking variable, LAI is deduced from FORMOSAT-2 reflectances images, and then introduced into the SAFY model to provide spatial and temporal estimates of these biophysical variables. Most of the SAFY parameters are crop related and have been fixed according to

  16. Combining high temporal and high spatial resolution thermal infrared datasets to detect volcanic precursors

    NASA Astrophysics Data System (ADS)

    Reath, K. A.; Dehn, J.; Ramsey, M. S.

    2013-12-01

    Most volcanoes produce some level of precursory activity prior to an eruption. In certain cases, the precursors can be interpreted to make forecasts about the time and magnitude of the impending eruption. Furthermore, subtle changes in this activity can be used to determine the style of an eruption at volcanoes known for differing eruption types. This study focuses on the effectiveness of using thermal infrared (TIR) spaceborne sensors to track volcanic precursors from thermal changes at the summit of volcanoes using data from both the ASTER and AVHRR sensors by focusing on the Kamchatka (Russia) region. At Bezymianny volcano, a clear increase in activity commonly occurs before an eruption, which has allowed predictions to be made months ahead of time. In other cases, such as the Tolbachik eruption in 2012, no precursors were detected before the large scale effusive eruption. However, most volcanoes do not fall into these extremes, as is the case with Kliuchevskoi volcano. Three large eruptions (e.g., 2005, 2007, 2009) have occurred at Kliuchevskoi in the past decade. Before each of these eruptions, AVHRR and ASTER detected thermal anomalies (pixels with radiant energy significantly above the background). High temporal but low spatial resolution (i.e., hours; 1 km) AVHRR data are ideal for detecting high energy events occurring over short time periods. In contrast, high spatial but low temporal resolution (i.e., days to weeks; 90 m) ASTER data enables the detection of much lower levels of activity. These smaller thermal anomalies are more commonly associated with the longer time scale pre-eruptive phase at Kliuchevskoi. The problem occurs where attempting to detect patterns in these anomalies over time. Only volcanic activity that produces a large amount of radiant energy can be seen with the relatively poor spatial resolution of AVHRR, and ASTER will commonly miss shorter duration activity. In this study, we use ASTER data to track low-level anomalies months prior

  17. Quantifying tree mortality in a mixed species woodland using multitemporal high spatial resolution satellite imagery

    USGS Publications Warehouse

    Garrity, Steven R.; Allen, Craig D.; Brumby, Steven P.; Gangodagamage, Chandana; McDowell, Nate G.; Cai, D. Michael

    2013-01-01

    Widespread tree mortality events have recently been observed in several biomes. To effectively quantify the severity and extent of these events, tools that allow for rapid assessment at the landscape scale are required. Past studies using high spatial resolution satellite imagery have primarily focused on detecting green, red, and gray tree canopies during and shortly after tree damage or mortality has occurred. However, detecting trees in various stages of death is not always possible due to limited availability of archived satellite imagery. Here we assess the capability of high spatial resolution satellite imagery for tree mortality detection in a southwestern U.S. mixed species woodland using archived satellite images acquired prior to mortality and well after dead trees had dropped their leaves. We developed a multistep classification approach that uses: supervised masking of non-tree image elements; bi-temporal (pre- and post-mortality) differencing of normalized difference vegetation index (NDVI) and red:green ratio (RGI); and unsupervised multivariate clustering of pixels into live and dead tree classes using a Gaussian mixture model. Classification accuracies were improved in a final step by tuning the rules of pixel classification using the posterior probabilities of class membership obtained from the Gaussian mixture model. Classifications were produced for two images acquired post-mortality with overall accuracies of 97.9% and 98.5%, respectively. Classified images were combined with land cover data to characterize the spatiotemporal characteristics of tree mortality across areas with differences in tree species composition. We found that 38% of tree crown area was lost during the drought period between 2002 and 2006. The majority of tree mortality during this period was concentrated in piñon-juniper (Pinus edulis-Juniperus monosperma) woodlands. An additional 20% of the tree canopy died or was removed between 2006 and 2011, primarily in areas

  18. High-spatial resolution numerical simulations of in-water radiative transfer processes

    NASA Astrophysics Data System (ADS)

    D'Alimonte, D.; Kajiyama, T.; Zibordi, G.

    2012-04-01

    Monte Carlo (MC) simulations of radiative processes allow for addressing optical radiometric problems strictly linked to complex geometries. Within such a context, MC simulations have been used to investigate uncertainties affecting in-water radiometric measurements performed with free-fall optical profilers commonly utilized for the vicarious calibration of space sensors or the validation of satellite ocean color primary products (e.g, the normalized water leaving radiance). Specifically, a MC code (henceforth called MOX) has been developed to simulate in-water and above-water radiometric fields with high spatial-resolution (up to 1 cm) over a 2-dimensional (2D) domain of tens of meters. This has been achieved by exploiting high performance computing (HPC) solutions (e.g., parallel programs and job-scheduling based on novel performance prediction and optimization schemes) to trace up to 10^12 photons. A dedicated study, focused on the simulation of in-water radiometric fields, has led to the generation of virtual optical profiles accounting for perturbations due to light focusing effect by sea-surface gravity and capillary waves at a spatial resolution comparable to that of actual measurements. Different from field experiments, which are often constrained by environmental factors like illumination conditions and sea-water optical properties, numerical simulations permits analyzing realistic cases whereas allowing for a free input parameter selection. MOX simulations have shown that uncertainties induced by focusing effects upon radiometric data products can be reduced by slowing the deployment speed of free-fall optical profilers, rather than increasing the sampling frequency (i.e., while keeping the same number of samples per depth unit). This result has confirmed the appropriateness of profiling techniques (i.e., multicasting) so far solely supported by a limited number of field measurements and has additionally suggested the possibility of investigating further

  19. Modern high spatial resolution approaches to crustal evolution studies - pitfalls and progress

    NASA Astrophysics Data System (ADS)

    Whitehouse, M. J.

    2012-12-01

    Developments in analytical techniques for in situ geochronology and isotope geochemistry over the past few decades have contributed greatly to our understanding of the processes of Precambrian crustal evolution, plate tectonics, the development of Earth's hydrosphere and atmosphere and conditions for the development of life on Earth. The further back in time we go, however, the more complex the geology, requiring that we unravel and/or try to see through multiple phases of disturbance. Such geological complexity complicates interpretation and can lead to conflicting viewpoints on such key questions as when plate tectonics began on Earth, when it evolved to a process essentially similar to that of today and the nature and habitability of a potentially pre-plate tectonic Earth in the Hadean. This presentation will review, with case studies, some of the crucial aspects of applying and interpreting high spatial resolution in situ methods and some of the potential pitfalls. Obtaining accurate and precise geochronology is an essential first step in any study of Precambrian geology, whether it is the primary goal or provides a supporting framework to other diverse applications. To this end, high spatial resolution secondary ion mass spectrometry (SIMS) and laser ablation inductiively coupled plasma mass spectrometry (LA-ICPMS), typically combined with relevant imaging methods such as cathode luminescence (CL) are widely used to investigate the U-Pb systematics of complex zircon. In general precision is merely an analytical hurdle that we are go