Science.gov

Sample records for 10-0 nylon sutures

  1. COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS

    PubMed Central

    Silva, Ricardo Teixeira e; Barros, Thiago Felipe Santos; de Carvalho, José Thomé; Ribeiro, André Araújo; Pires, André Fernandes; Wei, Teng Hsiang

    2016-01-01

    ABSTRACT Objective: The aim of this study is to compare micro-sutures commonly used in our midst. Methods: In this double-blind study, 30 Wistar rats were operated randomly divided into three groups matched according to the suture used (Nylon 10-0, 75micron, brands Microsuture(r), Polysuture(r) and Ethicon(r)). We analyzed the number of surgical nodes required, bleeding, surgical time and histological evaluation. Results: There was no significant difference between the amount of stitches of arterial suture per anastomosis. Surgical time was longer in Microsuture(r) group as compared to Polysuture(r) (p ≤ 0.05). Bleeding in Microsuture(r) group was higher when compared to the others (p <0.01). In the histological analysis, the Microsuture(r) group showed a greater tendency to develop fibrosis and aneurysm in surgical site than the others (p <0.01 and p≤0,05, respectively). Similarly, the Ethicon(r) group showed less tendency to myointimal proliferation than the rest. (p = 0.025). Conclusion: The results confirm the relevance of the choice of surgical thread as an independent determining factor for the success of the procedure, besides serving as a rational subsidy for a better cost-benefit analysis. Level of Evidence I, Experimental Study, Controlled Animal Study. PMID:26997912

  2. Gingival response to silk, cotton, and nylon suture materials.

    PubMed

    Castelli, W A; Nasjleti, C E; Caffesse, R E; Diaz-Perez, R

    1978-02-01

    Silk, cotton, and nylon suture materials were implanted in the tunica propria of the gingiva in seven adult rhesus monkeys. The histologie study of twenty-four biopsy specimens indicated that there was neither an increase in the vascular permeability nor a leukocytic margination and migration into the tissues adjacent to the suture materials. However, there was a variable histiocytic reaction, with multinucleated cell formation. This reaction was quite intense with cotton, less intense with silk, and practically absent with nylon. The greater cellular response to cotton was probably due to its more active capacity for modifying the internal biologic medium of the gingvia.

  3. Effect of suture material on postoperative astigmatism.

    PubMed

    Gimbel, H V; Raanan, M G; DeLuca, M

    1992-01-01

    Two hundred patients were enrolled in a randomized, prospective clinical trial comparing the use of 10-0 nylon, 10-0 polypropylene (Prolene), 11-0 polyester (Mersilene), and 10-0 polyethylene (Novafil) suture materials on the amount and decay curves of surgically induced astigmatism following intraocular lens (IOL) surgery. Patients with Mersilene and nylon sutures had the highest amounts of induced with-the-rule (WTR) cylinder (significantly more than Prolene) at one day after surgery. However, the WTR cylinder decayed rapidly for nylon during the first three months but more slowly for Mersilene because of its lack of stretchability. The Prolene group had the lowest level of induced WTR cylinder at one day, but against-the-rule (ATR) drift occurred, leaving cases with ATR astigmatism by a year. The nylon group had the second highest amount of induced WTR cylinder at one day, which had decayed to ATR cylinder by five months. Between one and two years postoperatively, the nylon group experienced a significant ATR shift. The amount of early induced WTR cylinder seemed to be related to the knot-tying technique and tissue gripping characteristics, whereas the shape of the decay curve was related to the material characteristics of the suture. PMID:1531234

  4. Prolene monofilament suture in Boston Keratoprosthesis surgery

    PubMed Central

    Kyrillos,, Ralph; Harissi-Dagher, Mona

    2011-01-01

    Summary Toxic reaction to nylon following uncomplicated cataract surgery and vitrectomy has been documented in the literature. We report the case of an aniridic patient with a known adverse reaction to nylon in whom Prolene suture was used in Boston Keratoprosthesis type 1 (KPro) surgery. During follow-up the cornea was checked for signs of inflammation and toxic reaction; at last follow-up (18 months) the patient showed no signs of complications due to Prolene. Our study suggests that Prolene suture may be used as an alternative to nylon in Boston KPro surgery in patients with a history of nylon toxicity. PMID:23362386

  5. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and...

  6. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and...

  7. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and...

  8. Nylon separators. [thermal degradation

    NASA Technical Reports Server (NTRS)

    Lim, H. S.

    1977-01-01

    A nylon separator was placed in a flooded condition in K0H solution and heated at various high temperatures ranging from 60 C to 110 C. The weight decrease was measured and the molecular weight and decomposition product were analyzed to determine: (1) the effect of K0H concentration on the hydrolysis rate; (2) the effect of K0H concentration on nylon degradation; (3) the activation energy at different K0H concentrations; and (4) the effect of oxygen on nylon degradation. The nylon hydrolysis rate is shown to increase as K0H concentration is decreased 34%, giving a maximum rate at about 16%. Separator hydrolysis is confirmed by molecular weight decrease in age of the batteries, and the reaction of nylon with molecular oxygen is probably negligible, compared to hydrolysis. The extrapolated rate value from the high temperature experiment correlates well with experimental values at 35 degrees.

  9. Transcutaneous lower blepharoplasty, painless suture removal.

    PubMed

    De Vita, Roy; Buccheri, Ernesto Maria

    2013-01-01

    Despite being referred to as one of the more challenging procedures in plastic surgery, lower blepharoplasty is one of the most commonly requested and performed aesthetic procedures.Our experience, from February 2007 to March 2012, is based on 214 transcutaneous lower blepharoplasty procedures in which the skin flap was sutured by means of the epidermal-dermal U stitch, a new, simple, and reliable method. Patients were followed up for a mean period ranging from 7 to 70 months. To our knowledge, the literature proposes a single-stitch closure or continuous suture in transcutaneous lower blepharoplasty using nylon or silk 4-5-0 to close the skin incision (1-3-5). According to our experience before 2007 based on patients' reports, single-stitch subciliary suture removal is a source of stress for the patient that causes anxiety, discomfort, and pain.Thus, in February 2007, following transepithelial lower blepharoplasty, we started using a new, simple way to suture the subciliary skin flap adopting the epidermal-dermal U nylon 5-0 stitch to avoid any discomfort and drastically reduce the level of anxiety and pain at the time of suture removal. According to our experience, the healing of the wound does not require any subsequent scar revision resulting from healing defects or pathological scar tissue; the complication rate in our series is in keeping with that reported by other authors in the literature.In conclusion, our experience indicates that the suture technique we describe is an easily reproducible, rapid, discomfort-free, and painless means of removing stitches. PMID:24036781

  10. 15 CFR 10.0 - General.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 15 Commerce and Foreign Trade 1 2010-01-01 2010-01-01 false General. 10.0 Section 10.0 Commerce... PRODUCT STANDARDS § 10.0 General. (a) Introduction. The Department of Commerce (hereinafter referred to as... substantial public impact; (2) The proposed standard reflects the broad interest of an industry group or...

  11. Acid rain degradation of nylon

    SciTech Connect

    Kyllo, K.E.

    1984-01-01

    Acid rain, precipitation with a pH less than 5.6, is known to damage lakes, vegetation and buildings. Degradation of outdoor textiles by acid rain is strongly suspected but not well documented. This study reports the effects of sunlight, aqueous acid, heat and humidity (acid rain conditions) on spun delustered nylon 6,6 fabric. Untreated nylon and nylon treated with sulfuric acid of pH 2.0, 3.0, and 4.4 were exposed to light in an Atlas Xenon-arc fadeometer at 63/sup 0/C and 65% R.H. for up to 640 AATCC Fading Units. The untreated and acid treated nylon fabrics were also exposed to similar temperature and humidity condition without light. Nylon degradation was determined by changes in breaking strength, elongation, molecular weight, color, amino end group concentration (NH/sub 2/) and /sup 13/C NMR spectra. Physical damage was assessed using SEM.

  12. GENIE Production Release 2.10.0

    SciTech Connect

    Alam, M.; Andreopoulos, C.; Athar, M.; Bodek, A.; Christy, E.; Coopersmith, B.; Dennis, S.; Dytman, S.; Gallagher, H.; Geary, N.; Golan, T.; Hatcher, R.; Hoshina, K.; Liu, J.; Mahn, K.; Marshall, C.; Morrison, J.; Nirkko, M.; Nowak, J.; Perdue, G. N.; Yarba, J.

    2015-12-25

    GENIE is a neutrino Monte Carlo event generator that simulates the primary interaction of a neutrino with a nuclear target, along with the subsequent propagation of the reaction products through the nuclear medium. It additionally contains libraries for fully-featured detector geometries and for managing various types of neutrino flux. This note details recent updates to GENIE, in particular, changes introduced into the newest production release, version 2.10.0.

  13. Cellulose fiber reinforced nylon 6 or nylon 66 composites

    NASA Astrophysics Data System (ADS)

    Xu, Xiaolin

    Cellulose fiber was used to reinforce higher melting temperature engineering thermoplastics, such as nylon 6 and nylon 66. The continuous extrusion - direct compression molding processing and extrusion-injection molding were chosen to make cellulose fiber/nylon 6 or 66 composites. Tensile, flexural and Izod impact tests were used to demonstrate the mechanical properties of the composites. The continuous extrusion-compression molding processing can decrease the thermal degradation of cellulose fiber, but fiber doesn't disperse well with this procedure. Injection molding gave samples with better fiber dispersion and less void content, and thus gave better mechanical properties than compression molding. Low temperature compounding was used to extrude cellulose fiber/nylon composites. Plasticizer and a ceramic powder were used to decrease the processing temperature. Low temperature extrusion gave better mechanical properties than high temperature extrusion. The tensile modulus of nylon 6 composite with 30% fiber can reach 5GPa; with a tensile strength of 68MPa; a flexural modulus of 4GPa, and a flexural strength of 100MPa. The tensile modulus of nylon 66 composites with 30% fiber can reach 5GPa; with a flexural modulus of 5GPa; a tensile strength of 70MPa; and a flexural strength of 147MPa. The effect of thermal degradation on fiber properties was estimated. The Halpin-Tsai model and the Cox model were used to estimate the composite modulus. The Kelly-Tyson model was used to estimate the composite strength. The result indicates that the change of fiber properties determines the final properties of composites. Fiber length has a minor affect on both modulus and strength as long as the fiber length is above the critical length.

  14. Blends of zein and nylon-6

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Blends of zein and nylon-6(55k)were used to produce solution cast films and electrospun fibers. Zein was blended with nylon-6 in formic acid solution. When the amount of nylon-6 was 8% or less a compatible blend formed. The blend was determined to be compatible based on physical property measurement...

  15. RETENTION OF SULFUR DIOXIDE BY NYLON FILTERS

    EPA Science Inventory

    Based on laboratory studies, recovery efficiencies of sulfur dioxide (SO2) were determined for nylon filters. The nylon filters used in these experiments were found to retain SO2. A relatively uniform amount (1.7%) was recoverable from each nylon filter, independent of relative...

  16. Enzymatic hydrolysis of nylons: quantification of the reaction rate of nylon hydrolase for thin-layered nylons.

    PubMed

    Nagai, Keisuke; Iida, Kazuki; Shimizu, Kimiaki; Kinugasa, Ryo; Izumi, Motoki; Kato, Dai-Ichiro; Takeo, Masahiro; Mochiji, Kozo; Negoro, Seiji

    2014-10-01

    Nylon hydrolase degrades various aliphatic nylons, including nylon-6 and nylon-66. We synthesized a nylon-66 copolymer (M w = 22,900, M n = 7,400), in which a part of an adipoyl unit (32 % molar ratio) of nylon-66 was replaced with a succinyl unit by interfacial polymerization. To quantify the reaction rate of the enzymatic hydrolysis of nylons at the surface of solid polymers, we prepared a thin layer of nylons on the bottom surface of each well in a polystyrene-based micro-assay plate. The thickness of the nylon layer was monitored by imaging analysis of the photographic data. More than 99 % of the copolymer with thicknesses of 260 nm (approximately 600 layers of polymer strands) were converted to water-soluble oligomers by nylon hydrolase (3 mg enzyme ml(-1)) at 30 °C within 60 h. These results were further confirmed by TLC analysis of the reaction products and by assay of liberated amino groups in the soluble fractions. The degradation rate of the thin-layered nylon-6 was similarly analyzed. We demonstrate that this assay enables a quantitative evaluation of the reaction rate of hydrolysis at the interface between the solid and aqueous phases and a quantitative comparison of the degradability for various polyamides.

  17. Evaluation of five different suture materials in the skin of the earthworm (Lumbricus terrestris).

    PubMed

    Salgado, Melissa A; Lewbart, Gregory A; Christian, Larry S; Griffith, Emily H; Law, Jerry McHugh

    2014-01-01

    The purpose of this study was to determine which suture material is the most appropriate for dermal closure of terrestrial annelids. This paper describes the tissue reactions of the earthworm, Lumbricus terrestris, to five different types of suture materials in order to determine which suture material is the most appropriate for dermal closure. Silk, monofilament nylon, polydiaxonone, polyglactin 910, and chromic gut were studied. There was mild to moderate tissue reaction to all five suture materials. In all of the biopsies wound-healing reaction consisted of aggregates of blastemal cells which appeared in various stages of dedifferentiation from the body wall. Inflammatory cells infiltrated the wound sites, reminiscent of the typical foreign body reaction in vertebrates. The results indicate polyglactin 910 would be the best suture material with regards to tissue security and reaction scores. Chromic gut occupies the next position but there were problems with suture security over time. This appears to be the first suture material performance study on a terrestrial invertebrate. The earthworm, Lumbricus terrestris, was chosen for its wide availability, size, and the extensive species knowledge base. The earthworm may prove to be a good surgical/suture model for economically important invertebrates such as mollusks, tunicates, and insect larval stages. PMID:25143875

  18. Combined suture and clipping for the reconstruction of a ruptured blister-like aneurysm.

    PubMed

    Kantelhardt, Sven R; Archavlis, Eleftherios; Giese, Alf

    2016-10-01

    Blister-like aneurysms of the internal carotid artery (ICA) present a severe therapeutical challenge. While several reconstructive techniques are in use in case of acute rupture sacrifice of the parent vessel may be required. We present a combined technique of micro-sutures and clip application to repair the parent vessel in an intraoperatively ruptured blister-like aneurysm. Following temporary trapping of an intraoperatively ruptured 7-mm blister-like aneurysm four 8-0 nylon sutures were applied to adapt the vessel walls and support the branches of subsequently applied mini-clips. The combination of micro-sutures and mini-clips might be a valuable alternative to direct clipping or suturing in some cases with intraoperative rupture of blister-like aneurysms. PMID:27514829

  19. Combined suture and clipping for the reconstruction of a ruptured blister-like aneurysm.

    PubMed

    Kantelhardt, Sven R; Archavlis, Eleftherios; Giese, Alf

    2016-10-01

    Blister-like aneurysms of the internal carotid artery (ICA) present a severe therapeutical challenge. While several reconstructive techniques are in use in case of acute rupture sacrifice of the parent vessel may be required. We present a combined technique of micro-sutures and clip application to repair the parent vessel in an intraoperatively ruptured blister-like aneurysm. Following temporary trapping of an intraoperatively ruptured 7-mm blister-like aneurysm four 8-0 nylon sutures were applied to adapt the vessel walls and support the branches of subsequently applied mini-clips. The combination of micro-sutures and mini-clips might be a valuable alternative to direct clipping or suturing in some cases with intraoperative rupture of blister-like aneurysms.

  20. 7. Perineal suturing.

    PubMed

    Blease, Megan; Taylor, Kerry

    2016-04-01

    Preceptorship is the 15th series of 'Midwifery basics' targeted at practising midwives. The aim of these articles is to provide information to raise awareness of the impact of the work of midwives on women's experience, and encourage midwives to seek further information through a series of activities relating to the topic. During the transition from student midwife, the newly qualified practitioner (NQM) is required to obtain experience of perineal suturing. With exposure varying from student to student and inconsistency in teaching methods between hospital trusts, the NQM can be left feeling apprehensive and unsupported to learn this skill. Suturing is a major and sometimes traumatic event for childbearing women, whose experience can vary greatly, depending upon many factors, including environment, skill of those suturing, effective analgesia and waiting times. In this penultimate article of the series, Megan Blease and Kerry Taylor address the current issues and provide learning hints and tips for NQMs learning and practising the skill. PMID:27172679

  1. 38 CFR 10.0 - Adjusted service pay entitlements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Adjusted service pay entitlements. 10.0 Section 10.0 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUSTED COMPENSATION Adjusted Compensation; General § 10.0 Adjusted service pay entitlements. A veteran entitled...

  2. 38 CFR 10.0 - Adjusted service pay entitlements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Adjusted service pay entitlements. 10.0 Section 10.0 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUSTED COMPENSATION Adjusted Compensation; General § 10.0 Adjusted service pay entitlements. A veteran entitled...

  3. Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice.

    PubMed

    Avoine, Xytilis; Lussier, Bertrand; Brailovski, Vladimir; Inaekyan, Karine; Beauchamp, Guy

    2016-04-01

    The influence of the type of material used, knot configuration, and use of an additional throw on the tensile force at failure, the elongation, and the mode of failure of different configurations of linear sutures and knotted suture loops was evaluated in this in-vitro mechanical study. We hypothesized that all types of knots would significantly influence the initial force and elongation of suture materials and would influence the force and elongation at which the knotted loops break, but not their mode of failure. A total of 432 samples of 4 types of size 3-0 suture material (polydioxanone, polyglecaprone 25, polyglactin 910, and nylon), representing 9 configurations, were tested in a tensiometer. The configurations were 1 linear suture without a knot and the following loops: square (SQ) knot; surgeon's (SU) knot; granny (GR) knot; and sliding half-hitch (SHH) knot using either 4 and 5 or 3 and 4 throws, depending on the material. For polydioxanone, SQ and SU knots did not decrease the initial force at failure of the suture. Granny (GR) and SHH knots decreased the tensile force at failure and elongation by premature failure of the loop. For polyglecaprone 25, all knots decreased the initial force at failure of the suture, with SHH being weaker than the other knots. For coated polyglactin 910, all knots decreased the initial force at failure of the suture and slippage increased significantly compared with the other 3 sutures. The use of SQ knots with 3 throws did not result in a safe knot. For nylon, knots did not alter the original mechanics of the suture. In conclusion, all knots and types of suture material do not necessarily have the same effect on the initial tensile force at failure of suture materials. PMID:27127344

  4. Nanomechanical properties of facial sutures and sutural mineralization front.

    PubMed

    Radhakrishnan, P; Mao, J J

    2004-06-01

    The mechanical properties of craniofacial sutures have rarely been investigated. Three facial sutures-the pre-maxillomaxillary (PMS), the nasofrontal (NFS), and the zygomaticotemporal (ZTS)-and their corresponding sutural mineralization fronts in 8 young New Zealand White rabbits were subjected to nano-indentation with atomic force microscopy as a test of the hypothesis that they have different mechanical properties. The average elastic modulus of the PMS was 1.46 +/- 0.24 MPa (mean +/- SD), significantly higher than both the ZTS (1.20 +/- 0.20) and NFS (1.16 +/- 0.18). The average elastic moduli of sutural mineralization fronts 30 micro m away were significantly higher than their corresponding sutures and had the same distribution pattern: the PMS (2.07 +/- 0.24 MPa) significantly higher than both the ZTS (1.56 +/- 0.29) and NFS (1.71 +/- 0.22). Analysis of these data suggests that facial sutures and their immediately adjacent sutural mineralization fronts have different capacities for mechanical deformation. The elastic properties of sutures and sutural mineralization fronts are potentially useful for improving our understanding of their roles in development.

  5. Purification of caprolactam from recycled nylon

    DOEpatents

    Moens, Luc

    1999-01-01

    A method of removing 1,11-diamino-6-undecanone from the pyrolysis product of nylon comprising: a) pyrolyzing nylon-6 to form a pyrolyzate containing a caprolactam mixture; b) dissolving the caprolactam mixture in a solvent to form a solution; c) passing carbon dioxide gas through the solution to form a precipitate; d) removing the precipitate from the solution; and e) recovering the purified caprolactam from the solution.

  6. Purification of caprolactam from recycled nylon

    DOEpatents

    Moens, L.

    1999-07-06

    A method is disclosed of removing 1,11-diamino-6-undecanone from the pyrolysis product of nylon comprising: (a) pyrolyzing nylon-6 to form a pyrolyzate containing a caprolactam mixture; (b) dissolving the caprolactam mixture in a solvent to form a solution; (c) passing carbon dioxide gas through the solution to form a precipitate; (d) removing the precipitate from the solution; and (e) recovering the purified caprolactam from the solution. 3 figs.

  7. Terrane suturing, Mindoro, Philippines

    SciTech Connect

    Wynne, D.B.; McCabe, R.; Mazzullo, J.; Malicse, A.

    1985-01-01

    A middle to late Miocene suture zone (SZ) on Mindoro Island separates the older North Palawan Continental terrane (NPCT) (west) from the younger Central Philippine Arc Terrane (CPAT) (east). The SZ consists of mafic and ultramafic rocks and amphibolites thrust westward against slaty meta-sediments (NPCT). East of the SZ lies the East Mindoro Basin (EMB), separated from the SZ by the East Mindoro Fault Zone (EMFZ). Locally, topography and geology suggest normal motion on the EMFZ. However, in central Mindoro, topographic expression of the EMFZ is very diffuse and geologic map patterns are complex. Lithotectonic units and sequences are sometimes repeated and motion appears to have been multiphase. In the eastern central SZ, westerly thrust CPAT ( ) crystalline rocks are overlain by lower Pliocene shelfal limestone. This limestone contains both serpentinite pebbles and metamorphic, polcrystalline quartz grains near its base, thus constraining thrusting and terrane suturing to pre-Pliocene. 100 km NNW, at the town of Puerto Galera, the same relations are observed, although thrusting appears to have been SSW there. 100 km WNW of Puerto Galera, a northeast-dipping ophiolite on Ambil Island lies several km NE of slaty metasediments (NPCT ) on Luband Island. The authors suggest that these three ultramafic exposures represent western CPAT Basement, thrust westward against portions of the advancing NPCT.

  8. Sliding Wear Properties of HVOF Thermally Sprayed Nylon-11 and Nylon-11/Ceramic Composites on Steel

    NASA Astrophysics Data System (ADS)

    Jackson, L.; Ivosevic, M.; Knight, R.; Cairncross, R. A.

    2007-12-01

    Polymer and polymer/ceramic composite coatings were produced by ball-milling 60 μm Nylon-11 together with nominal 10 vol.% of nano and multiscale ceramic reinforcements and by HVOF spraying these composite feedstocks onto steel substrates to produce semicrystalline micron and nanoscale reinforced polymer matrix composites. Room temperature dry sliding wear performance of pure Nylon-11, Nylon-11 reinforced with 7 nm silica, and multiscale Nylon-11/silica composite coatings incorporating 7-40 nm and 10 μm ceramic particles were characterized using a pin-on-disk tribometer. Coefficient of friction and wear rate were determined as a function of applied load and coating composition. Surface profilometry and scanning electron microscopy were used to characterize and analyze the coatings and wear scars. The pure Nylon-11 coating experienced less wear than the composites due to the occurrence of two additional wear mechanisms: abrasive and fatigue wear.

  9. Barbed sutures in body surgery.

    PubMed

    Moya, Alexander P

    2013-09-01

    Wound-closing technology continues to evolve with the advent of barbed sutures, which appear to address some of the limitations of traditional sutures (numerous knots and time-consuming insertion, among other things). Advantages of knotless suture devices, specifically in body contouring, have been discussed in the literature over the past decade, with a recent increase over the past several years due to the US Food and Drug Administration (FDA) approval of unidirectional V-Loc (Covidien, Mansfield, Massachusetts) and bidirectional Quill (Angiotech Pharmaceuticals, Inc, Vancouver, British Columbia, Canada) barbed sutures for soft tissue approximation. A thorough review of the existing literature and evaluation of the author's personal experience are presented in this article. As with any new surgical device, a learning curve is present that needs to be overcome to realize the full benefits of utilizing barbed sutures in body surgery while minimizing their complications.

  10. Nylon Dissolution in Nitric Acid Solutions

    SciTech Connect

    KESSINGER, GLENF.

    2004-06-16

    H Area Operations is planning to process Pu-contaminated uranium scrap in support of de-inventory efforts. Nylon bags will be used to hold materials to be dissolved in H-Canyon. Based on this set of twelve nylon dissolutions, it is concluded that (when other variables are held constant): increased acid concentration results in increased dissolution rates; increased acid concentration results in a lower dissolution onset temperature; little, if any, H plus is consumed during the depolymerization process; and 2.0-3.0 M HNO3, with 0.025 M KF and 2 g/L B, is satisfactory for the dissolution of nylon bag materials to be used during H-Canyon processing.

  11. Gliding Resistance and Strength of a Braided Polyester/Monofilament Polyethylene Composite (FiberWire®) Suture in Human Flexor Digitorum Profundus Tendon Repair: An In-Vitro Biomechanical Study

    PubMed Central

    Silva, Jose M.; Zhao, Chunfeng; An, Kai-Nan; Zobitz, Mark E.; Amadio, Peter C.

    2009-01-01

    Purpose While the strength of a tendon repair is clearly important, the friction of the repair is also a relevant consideration. The purpose of this study was to characterize the frictional coefficient, gliding resistance and breaking strength of suture materials and a suture construct commonly used for flexor tendon repair. Methods We measured the friction coefficients of 3-0 braided nylon enclosed in a smooth nylon outer shell (Supramid, S. Jackson, Alexandria, VA), 3-0 braided polyester coated with polybutilate (Ethibond, Ethicon, Somerville, NJ), and a 3-0 braided polyester/monofilament polyethylene composite (FiberWire, Arthrex, Naples, FL) sutures. We also measured the gliding resistance, linear breaking strength and resistance to gapping of zone 2 modified Pennington tendon repairs with the two lowest friction sutures in 20 human cadaveric flexor digitorum profundus (FDP) tendons. Results The braided polyester/monofilament polyethylene composite had a significantly lower friction coefficient (0.054) than either the coated polyester (0.076) or nylon (0.130) sutures (p<0.001). The gliding resistances of the repaired tendons with braided/monofilament polyethylene composite suture and coated, braided polyester were similar (p> 0.05). The strength of the two repairs, force to produce a 2mm gap, and resistance to gap formation than coated, braided polyester repairs were also not significantly different. Conclusion Braided polyester composite is a low friction suture material. However, when this suture was used for tendon repair with a locking suture technique, it did not show a significant effect on the gliding resistance and repair strength compared with the same repair using coated polyester suture. PMID:19121735

  12. Reusing nylon membranes for radioactive hybridizations.

    PubMed

    Thornbury, D W; Farman, M L

    2000-12-01

    We describe a procedure for recycling nylon hybridization membranes, enabling their repeated use for radioactive Southern hybridization analysis of different DNA samples. Following hybridization and probe removal, nylon membranes containing covalently linked DNAs were treated with 0.55% sodium hypochlorite. This destroyed the DNA, thereby preventing it from participating in further hybridization and enabling the membranes to be used subsequently for binding new DNA samples. With this procedure, we were able to reuse a single membrane as many as 13 times, with no detectable loss in signal. This method was shown to be effective for membranes supplied by three different manufacturers.

  13. Current applications of endoscopic suturing

    PubMed Central

    Stavropoulos, Stavros N; Modayil, Rani; Friedel, David

    2015-01-01

    Endoscopic suturing had previously been considered an experimental procedure only performed in a few centers and often by surgeons. Now, however, endoscopic suturing has evolved sufficiently to be easily implemented during procedures and is more commonly used by gastroenterologists. We have employed the Apollo OverStitch suturing device in a variety of ways including closure of perforations, closure of full thickness defects in the gastrointestinal wall created during endoscopic full thickness resection, closure of mucosotomies during peroral endoscopic myotomy, stent fixation, fistula closure, post endoscopic submucosal dissection, endoscopic mucosal resection and Natural Orifice Transluminal Endoscopic Surgery defect closures, post-bariatric surgery gastrojejunal anastomosis revision and primary sleeve gastroplasty. PMID:26191342

  14. Maintenance Manual for Carpets Made with Du Pont Carpet Nylon.

    ERIC Educational Resources Information Center

    Du Pont Corp., Wilmington, DE.

    Information is divided into the following sections--(1) the selection of nylon carpet, (2) the advantages of nylon for carpets, (3) the characteristics of nylon carpet, (4) soiling and soil retardants, (5) vacuum cleaning, (6) spot cleaning and freshening of traffic lanes, (7) wet cleaning (shampooing), and (8) miscellaneous carpet maintenance…

  15. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as...

  16. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as...

  17. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Mineral reinforced nylon resins. 177.2355 Section... Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in... accordance with the following prescribed conditions: (a) For the purpose of this section the...

  18. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as...

  19. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as...

  20. Nylon 610/graphene oxide composites prepared by in-situ interfacial polymerization.

    PubMed

    Lee, Jaehoon; Yun, Young Soo; Kim, Bona; Cho, Se Youn; Jin, Hyoung-Joon

    2014-08-01

    Nylon 610/nylon 610-grafted graphene oxide (nylon 610/GO-g-nylon 610) composites were fabricated using acyl chloride-functionalized graphene oxide by in-situ interfacial polymerization. GO-g-nylon 610 was synthesized by the condensation reaction between the acyl chloride groups of GO and the amino groups at the nylon 610 chains during the in-situ polymerization. Nylon 610/GO composites without grafting nylon 610 onto GO were also prepared to investigate the influence of grafting nylon 610 on the interfacial adhesion between GO and the nylon 610 matrix. The thermal properties of the nylon 610/GO-g-nylon 610 composites were enhanced with increasing GO-g-nylon 610 content in the nylon 610 matrix. The degradation temperature and thermal conductivity of the nylon 610/GO-g-nylon 610-10 composite were increased to 72.2 °C and 36.9%, respectively, compared with those of pure nylon 610. The crystallinity of the nylon 610/GO-g-nylon 610-10 composite was significantly lower than that of pure nylon 610 due to the hindered mobility of the nylon 610 chains by the strong interfacial adhesion between the GO-g-nylon 610 and the nylon 610 matrix.

  1. Craniosynostosis of the lambdoid suture.

    PubMed

    Rhodes, Jennifer L; Tye, Gary W; Fearon, Jeffrey A

    2014-08-01

    Craniosynostosis affecting the lambdoid suture is uncommon. The definition of lambdoid craniosynostosis solely applies to those cases demonstrating true suture obliteration, similar to other forms of craniosynostosis. In patients presenting with posterior plagiocephaly, true lambdoid craniosynostosis must be differentiated from the much more common positional molding. It can occur in a unilateral form, a bilateral form, or as part of a complex craniosynostosis. In children with craniofacial syndromes, synostosis of the lambdoid suture most often is seen within the context of a pansynostotic picture. Chiari malformations are commonly seen in multisutural and syndromic types of craniosynostosis that affect the lambdoid sutures. Posterior cranial vault remodeling is recommended to provide adequate intracranial volume to allow for brain growth and to normalize the skull shape. Although many techniques have been described for the correction of lambdoid synostosis, optimal outcomes may result from those techniques based on the concept of occipital advancement.

  2. Craniosynostosis of the Lambdoid Suture

    PubMed Central

    Rhodes, Jennifer L.; Tye, Gary W.; Fearon, Jeffrey A.

    2014-01-01

    Craniosynostosis affecting the lambdoid suture is uncommon. The definition of lambdoid craniosynostosis solely applies to those cases demonstrating true suture obliteration, similar to other forms of craniosynostosis. In patients presenting with posterior plagiocephaly, true lambdoid craniosynostosis must be differentiated from the much more common positional molding. It can occur in a unilateral form, a bilateral form, or as part of a complex craniosynostosis. In children with craniofacial syndromes, synostosis of the lambdoid suture most often is seen within the context of a pansynostotic picture. Chiari malformations are commonly seen in multisutural and syndromic types of craniosynostosis that affect the lambdoid sutures. Posterior cranial vault remodeling is recommended to provide adequate intracranial volume to allow for brain growth and to normalize the skull shape. Although many techniques have been described for the correction of lambdoid synostosis, optimal outcomes may result from those techniques based on the concept of occipital advancement. PMID:25210507

  3. Craniosynostosis of the lambdoid suture.

    PubMed

    Rhodes, Jennifer L; Tye, Gary W; Fearon, Jeffrey A

    2014-08-01

    Craniosynostosis affecting the lambdoid suture is uncommon. The definition of lambdoid craniosynostosis solely applies to those cases demonstrating true suture obliteration, similar to other forms of craniosynostosis. In patients presenting with posterior plagiocephaly, true lambdoid craniosynostosis must be differentiated from the much more common positional molding. It can occur in a unilateral form, a bilateral form, or as part of a complex craniosynostosis. In children with craniofacial syndromes, synostosis of the lambdoid suture most often is seen within the context of a pansynostotic picture. Chiari malformations are commonly seen in multisutural and syndromic types of craniosynostosis that affect the lambdoid sutures. Posterior cranial vault remodeling is recommended to provide adequate intracranial volume to allow for brain growth and to normalize the skull shape. Although many techniques have been described for the correction of lambdoid synostosis, optimal outcomes may result from those techniques based on the concept of occipital advancement. PMID:25210507

  4. 31 CFR 10.0 - Scope of part.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... Money and Finance: Treasury Office of the Secretary of the Treasury PRACTICE BEFORE THE INTERNAL REVENUE SERVICE § 10.0 Scope of part. This part contains rules governing the recognition of attorneys, certified public accountants, enrolled agents, and other persons representing clients before the Internal...

  5. An Inexpensive Suture Practice Board

    PubMed Central

    Kasdan, Morton L.; Wilhelmi, Bradon J.

    2015-01-01

    Objective: We provide a design for an effective suture practice board for surgical instruction that is both easily assembled and repaired. Methods: This model's design is achieved through inexpensive materials that do not compromise adequate simulation through repetitive use. We used a wooden board, synthetic microfiber cloth, and metal plates and screws to create the suture board. Two pieces of synthetic microfiber cloth, folded along the long axis, were attached to the outer edges of the wooden board using an electric screwdriver, with the metal plates and screws to secure the attachment. Results: Upon completion of construction, we have a board sufficient for instructing various suturing techniques. Conclusions: Our suture board design provides an effective practice material that is an improvement in cost, as well as reusability compared with other models. Our board has the advantage over animal tissues, such as chicken's or pigs’ feet, because it is not perishable and maintains its durability over extended periods of time. This model is advantageous compared with other commercially available synthetic models because the materials are cheaper and more easily replaced. Our suture board model provides sufficient simulation to enhance the user's skills across various suturing techniques in a manner that is cost-effective in production and maintenance. PMID:26693271

  6. Nylon screws make inexpensive coil forms

    NASA Technical Reports Server (NTRS)

    Aucoin, G.; Rosenthal, C.

    1978-01-01

    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  7. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... percent by weight of resin) Water 95percent ethyl alcohol Ethyl acetate Benzene 1. Nylon 66 resins 1.14... chapter, except those containing more than 8 percent alcohol, under conditions of use B through H... percent alcohol (by volume) at temperatures not to exceed 49 °C (120 °F) (conditions of use E, F, and G...

  8. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... percent by weight of resin) Water 95percent ethyl alcohol Ethyl acetate Benzene 1. Nylon 66 resins 1.14... chapter, except those containing more than 8 percent alcohol, under conditions of use B through H... percent alcohol (by volume) at temperatures not to exceed 49 °C (120 °F) (conditions of use E, F, and G...

  9. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Water 95percent ethyl alcohol Ethyl acetate Benzene 1. Nylon 66 resins 1.14±.015 475-495 Dissolves in 1... alcohol, under conditions of use B through H described in table 2 of § 176.170(c) of this chapter. 10.1... holding food, excluding beverages containing more than 8 percent alcohol (by volume) at temperatures...

  10. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... percent by weight of resin) Water 95percent ethyl alcohol Ethyl acetate Benzene 1. Nylon 66 resins 1.14... chapter, except those containing more than 8 percent alcohol, under conditions of use B through H... percent alcohol (by volume) at temperatures not to exceed 49 °C (120 °F) (conditions of use E, F, and G...

  11. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... percent by weight of resin) Water 95percent ethyl alcohol Ethyl acetate Benzene 1. Nylon 66 resins 1.14... chapter, except those containing more than 8 percent alcohol, under conditions of use B through H... percent alcohol (by volume) at temperatures not to exceed 49 °C (120 °F) (conditions of use E, F, and G...

  12. Biomechanics of craniofacial sutures: orthopedic implications.

    PubMed

    Mao, Jeremy J; Wang, Xin; Kopher, Ross A

    2003-04-01

    Sutures are soft connective tissue articulations between craniofacial bones. Suture mechanics deals with patterns of mechanical stress experienced in sutures resulting from natural activities such as mastication and exogenous forces such as orthopedic loading. Patterns of sutural mechanical stress can be delineated readily as sutural strain using strain gages attached over the suture. In mastication, complex sutural strain patterns have been elucidated in a few species. Mechanical stresses are not transmitted in the skull as a continuing gradient, for different sutures are capable of redefining a propagating mechanical force as predominately tensile or compressive strain. Exogenous mechanical forces with engineering waveforms such as static and sine wave at different frequencies induce corresponding waveforms and rates of sutural strain, providing the basis for applying novel mechanical stimuli to engineer sutural growth. The available data on suture mechanics converge to a hypothetical theme that mechanical forces regulate sutural growth by inducing sutural mechanical strain. Various orthopedic therapies, including headgear, facemask, and functional appliances may induce sutural strain, leading to modification of otherwise natural suture growth.

  13. Bacterial colonization of percutaneous sutures.

    PubMed

    Gristina, A G; Price, J L; Hobgood, C D; Webb, L X; Costerton, J W

    1985-07-01

    The direct electron microscopic examination of 15 sutures and 15 staples removed from 10 healed surgical wounds showed, on the intradermal portions, consistent colonization by bacteria growing in adherent biofilms. This clearly demonstrable bacterial colonization of biomaterials within the wound tract had not resulted in infection or perceptible inflammation in any of the wounds. These bacterial cells were of several morphotypes, including gram-positive cocci, and all specimens yielded cultures of the autochthonous (native) skin bacterium, Staphylococcus epidermidis. The bacteria within the wound tracts were enveloped by extracellular material that appeared on scanning electron microscopy to be a condensed amorphous residue and on transmission electron microscopy to be a fibrous extracellular matrix. We suggest that this mode of growth, in which the colonizing bacteria are enveloped in a copious exopolysaccharide glycocalix, protects the bacteria from host defense factors and accounts for their persistence on the suture surfaces until they are removed with the sutures.

  14. Propagation of tears in pericardium from young bulls: influence of the suture.

    PubMed

    Páez, José María García; Jorge-Herrero, Eduardo; Claramunt, Rafael; Millán, Isabel; Rocha, Aurora; Martínez, Belén; Cordón, Angeles; Ros, Antonio

    2010-03-01

    The tearing of the collagen fibers of biological materials utilized in implants or bioprostheses is an important, and sometimes early cause of the failure of these devices. We studied the force necessary to propagate a tear in a biomaterial, pericardium from young bulls, and the influence of the suture. An Elmendorf pendulum capable of measuring the force necessary to tear a given length of tissue was employed. We analyzed 112 trials (70%) that proved valid after achieving the homogeneity of the samples according to their thickness, thus making the results comparable. Mean forces ranging between 19.87 and 150 N were required to propagate tears measuring from 0.25 to 2.0 cm. In the samples with a 1-cm-long suture, sewn using an edge-to-edge technique, the propagation of the tear required a mean force of 15.75 N when the suture was made of nylon and 28.73 N when Prolene was utilized. When these results were compared with the mean recorded in an unsutured control series (56.76 N), the loss of resistance was significant in both sutured series (P = 0.000 and P = 0.011, respectively). Finally, the equation that relates the force (y) with the length of the tear made in unsutured tissue (x) was also obtained: y = 58.14 + 9.62x(2) (R(2) = 0.924). The force necessary to produce a microtear, thus estimated, can be utilized as a parameter for comparison.

  15. Absorption of water and lubricating oils into porous nylon

    NASA Technical Reports Server (NTRS)

    Bertrand, P. A.

    1995-01-01

    Oil and water absorption from air into sintered porous nylon can be described by infiltration into the pores of the material. This process can be modeled by a diffusion-like mechanism. For water absorption, we find a formal diffusion coefficient of 1.5 x 10(exp -4)sq cm/min when the nylon is initially dry. The diffusion coefficient is 4 x 10(exp -6)sq cm/min when the nylon is oil-impregnated prior to air exposure. In a 52% RH atmosphere, dry nylon absorbs 3% w/w water, and oil-impregnated nylon absorbs 0.6% w/w water. For oil absorption there are three steps: (1) surface absorption and infiltration into (2) larger and (3) smaller pores. Surface absorption is too fast to be measured in these experiments. The diffusion coefficient for the second step is 6 x 10(exp -4)sq cm/min for SRG-60 oil into dry nylon and 4 x 10(exp -4)sq cm/min for air-equilibrated nylon. The diffusion coefficient for the third step is about 1 x 10(exp -6)sq cm/min for both cases. The total amount of oil absorbed is 31% w/w. The interaction between water and nylon is not as strong as that between water and cotton-phenolic: oil can replace water, and only a small amount of water can enter previously oil-impregnated nylon.

  16. Terminal Area Simulation System User's Guide - Version 10.0

    NASA Technical Reports Server (NTRS)

    Switzer, George F.; Proctor, Fred H.

    2014-01-01

    The Terminal Area Simulation System (TASS) is a three-dimensional, time-dependent, large eddy simulation model that has been developed for studies of wake vortex and weather hazards to aviation, along with other atmospheric turbulence, and cloud-scale weather phenomenology. This document describes the source code for TASS version 10.0 and provides users with needed documentation to run the model. The source code is programed in Fortran language and is formulated to take advantage of vector and efficient multi-processor scaling for execution on massively-parallel supercomputer clusters. The code contains different initialization modules allowing the study of aircraft wake vortex interaction with the atmosphere and ground, atmospheric turbulence, atmospheric boundary layers, precipitating convective clouds, hail storms, gust fronts, microburst windshear, supercell and mesoscale convective systems, tornadic storms, and ring vortices. The model is able to operate in either two- or three-dimensions with equations numerically formulated on a Cartesian grid. The primary output from the TASS is time-dependent domain fields generated by the prognostic equations and diagnosed variables. This document will enable a user to understand the general logic of TASS, and will show how to configure and initialize the model domain. Also described are the formats of the input and output files, as well as the parameters that control the input and output.

  17. ESR study of gamma irradiated Nylon3

    NASA Astrophysics Data System (ADS)

    Çatiker, Efkan; Güven, Olgun; Özarslan, Özdemir; Chipara, Mircea

    2013-03-01

    Nylon3 (poly-β-alanine) gamma irradiated in nitrogen was investigated by Electron Spin Resonance Spectroscopy to elucidate the type of radicals generated, their relative abundance, conversion into other radicalic species and their room temperature stability. Two types of radiation induced primary radicals have been detected. One of them (R1) occurs by hydrogen abstraction from methylene group next to the carbonyl group, while the other (R2) by hydrogen abstraction from methylene group next to amide group. R1 is observed to be converted into an alkoxy radical (R3). Decay kinetics of the radicals in nitrogen was also examined and decay mechanisms have been proposed for each radical.

  18. Cellular interactions and stimulated biological functions mediated by nanostructured carbon for tissue reconstruction and tracheal tubes and sutures.

    PubMed

    Misra, R D K; Chaudhari, P M

    2013-02-01

    Nylon 6,6 is used for biological applications including gastrointestinal segments, tracheal tubes and sutures, vascular graft, and for hard tissue reconstruction. While it is a relatively inexpensive polymer, it is not widely acceptable as a preferred biomaterial because of bioactivity. To this end, we have discovered the exciting evidence that introduction of a novel nanostructured carbon, graphene, in the void space between the nylon chains and processing at elevated pressure favorably stimulates cellular functions and provides high degree of cytocompatibility. The cell-substrate interactions on stand alone Nylon 6,6 and Nylon 6,6-graphene oxide hybrid system were investigated in terms of cell attachment, viability, proliferation, and assessment of proteins, actin, vinculin, and fibronectin. The enhanced biological functions in the nanostructured hybrid system are attributed to relatively superior hydrophilicity of the surface and to the presence of graphene. Furthermore, it is proposed that the negatively charged graphene interacts with the polar nature of cells and the culture medium, such that the interaction is promoted through polar forces. This is accomplished by investigating cell attachment, proliferation, and morphology, including cytomorphometry evaluation, and quantitative assessment of prominent proteins, actin, vinculin, and fibronectin that are sensitive to cell-substrate interactions. Osteoblasts were studied to establish the practical viability of the hybrid nanostructured biomaterial. The study strengthens the foundation for utilizing nano- or quantum-size effects of nanostructured biomaterials.

  19. [Gynecologist used different suture material for tubal ligation; patient's complaint that she was not informed of this declared unfounded].

    PubMed

    1980-06-14

    A woman who became pregnant after having undergone a sterilization operation filed a legal suit against the physician who had performed the operation. The sterilization was performed in a polyclinic, a vaginal approach was used for tubal ligation, and the proximal stump end was sutured with Vicryl instead of the more usual nylon. The operating physician used Vicryl because it dissolves completely in the body and would induce a tissue reaction which would better occlude the ligated end of the tube; nylon sutures can slip out spontaneously and allow fertilization. A patient became pregnant, and a follow-up examination of 17 other patients who had undergone the procedure showed other cases of permeable Fallopian tubes and 2 other incidences of pregnancy. The patient filed suit against the physician for failing to inform her of the change in suture material, for failing to inform her of other pregnancies that occurred after this operation, and for failure to recommend that the patient undergo a check-up examination.

  20. Classroom Illustrations of Acidic Air Pollution Using Nylon Fabric

    ERIC Educational Resources Information Center

    Campbell, Dean J.; Wright, Emily A.; Dayisi, Mardhia O.; Hoehn, Michael R.; Kennedy, Branden F.; Maxfield, Brian M.

    2011-01-01

    In 1970, deposition of fly ash from a coal burning power plant in downtown Peoria produced minor damage in the vicinity of its smokestack, including runs in ladies nylon stockings. In this article, we review the historical event and discuss the chemistry behind the depolymerization of the nylon, as well as laboratory experiments demonstrating how…

  1. Suture anchor versus suture through tunnel fixation for quadriceps tendon rupture: a biomechanical study.

    PubMed

    Lighthart, William A; Cohen, David A; Levine, Richard G; Parks, Brent G; Boucher, Henry R

    2008-05-01

    This biomechanical study compared suture anchors versus transosseous sutures for repair of quadriceps tendon ruptures using a force of 150 N at a frequency of 0.5 Hz. No significant difference in displacement was found between the 2 techniques with initial loading or with load or no load after 1000 cycles. Displacement after 1000 cycles for suture anchors and bone tunnels was 4.65 and 4.50 mm, respectively. These findings suggest a possible role for suture anchors in repairing quadriceps tendon ruptures. Suture anchors are relatively expensive but require less dissection over the patella and do not involve suture placement about the patella tendon.

  2. Experimental investigation on the mechanical properties of glass fiber reinforced nylon

    NASA Astrophysics Data System (ADS)

    Nuruzzaman, D. M.; Iqbal, A. K. M. Asif; Oumer, A. N.; Ismail, N. M.; Basri, S.

    2016-02-01

    In this study, the influence of different weight percentages of glass fiber (GF) reinforcement on the mechanical properties of nylon (PA6) composite is investigated. Test specimens of pure nylon, 95% nylon + 5% GF, 90% nylon + 10% GF, 85% nylon + 15% GF and 80% nylon + 20% GF are prepared using an injection molding machine. In the experiments, tensile tests and impact tests are carried out. The obtained results reveal that mechanical properties of the nylon composites are significantly influenced by the weight percentage of glass fiber. From the tensile test results, it is observed that pure nylon has the lowest elastic modulus and yield strength whereas 80% nylon + 20% GF composite shows the highest elastic modulus and yield strength. Moreover, pure nylon shows the lowest tensile strength while 80% nylon + 20% GF shows significantly improved tensile strength. Results show that elongation at break is remarkably high for pure nylon whereas it is very low for 80% nylon + 20% GF. Izod impact test results reveal that, 85% nylon + 15% GF composite has the highest impact strength or toughness whereas 95% nylon + 5% GF composite shows the lowest impact strength. Furthermore, 80% nylon + 20% GF composite shows somewhat less impact strength or toughness than 85% nylon + 15% GF composite.

  3. Tram-Track Suture Technique for Pupillary Capture of a Scleral Fixated Intraocular Lens

    PubMed Central

    Kim, Sung In; Kim, Kiseok

    2016-01-01

    Purpose To report a new technique using tram-track suture for pupillary capture of a scleral fixated posterior chamber intraocular lens (PC-IOL) to reposition the tilted IOL. Methods In this prospective interventional case series, we describe a tram-track suture for pupillary capture of a scleral fixated PC-IOL. A long straight needle with double-armed 10-0 polypropylene is passed behind the iris and just above the optic portion (tilted forward) of the IOL. The other straight needle with double-armed 10-0 polypropylene is passed just below the optic portion (tilted backward) of the IOL. After the IOL is repositioned properly, the polypropylene sutures are gently pulled and tied. Results Four eyes of 4 patients underwent tram-track suture for pupillary capture of a scleral fixated PC-IOL. No intra- or postoperative complications were noted, and no pupillary captures were detected during the follow-up period. Conclusions The tram-track suture technique provides good centration and stability of a PC-IOL. This technique is an easy and effective way to reposition pupillary capture of an IOL. Further, it is also minimally invasive as it maintains a closed system. PMID:27462257

  4. Suture materials affect peri-implant bone healing and implant osseointegration.

    PubMed

    Villa, Oscar; Lyngstadaas, Staale P; Monjo, Marta; Satué, Maria; Rønold, Hans J; Petzold, Christiane; Wohlfahrt, Johan C

    2015-09-01

    The aim of this study was to evaluate the effects of the remnants of two suture materials on osseointegration of titanium implants in a rabbit tibial model. Calibrated defects were prepared in the tibia of five Chinchilla rabbits. Filaments of nonresorbable (NR) nylon or resorbable (R) chitosan were placed at the bone to implant interface, whereas control sites had no suture material. After a healing period of 4 weeks, a pull-out test procedure was performed followed by enzymatic analyses of the wound fluid and relative quantification of mRNA levels for bone-related and cytokine markers from the peri-implant bone. A trend toward a reduced pull-out force was observed in the NR group (NR: 23.0 ± 12.8 N; R: 33.9 ± 11.3 N; control: 33.6 ± 24.0 N). Similarly, the bone resorption marker vacuolar type H+-ATPase was increased in the NR group compared with that in the control group (P = 0.041). The R group showed trends for lower alkaline phosphatase activity and osteocalcin expression and higher total protein content and RNA compared with the control group. In this submerged healing model, peri-implant bone healing was marginally affected by the two suture materials tested. However, there was a tendency toward better osseointegration and lower expression of bone resorption markers in the R group compared with the control group.

  5. Suture materials affect peri-implant bone healing and implant osseointegration.

    PubMed

    Villa, Oscar; Lyngstadaas, Staale P; Monjo, Marta; Satué, Maria; Rønold, Hans J; Petzold, Christiane; Wohlfahrt, Johan C

    2015-09-01

    The aim of this study was to evaluate the effects of the remnants of two suture materials on osseointegration of titanium implants in a rabbit tibial model. Calibrated defects were prepared in the tibia of five Chinchilla rabbits. Filaments of nonresorbable (NR) nylon or resorbable (R) chitosan were placed at the bone to implant interface, whereas control sites had no suture material. After a healing period of 4 weeks, a pull-out test procedure was performed followed by enzymatic analyses of the wound fluid and relative quantification of mRNA levels for bone-related and cytokine markers from the peri-implant bone. A trend toward a reduced pull-out force was observed in the NR group (NR: 23.0 ± 12.8 N; R: 33.9 ± 11.3 N; control: 33.6 ± 24.0 N). Similarly, the bone resorption marker vacuolar type H+-ATPase was increased in the NR group compared with that in the control group (P = 0.041). The R group showed trends for lower alkaline phosphatase activity and osteocalcin expression and higher total protein content and RNA compared with the control group. In this submerged healing model, peri-implant bone healing was marginally affected by the two suture materials tested. However, there was a tendency toward better osseointegration and lower expression of bone resorption markers in the R group compared with the control group. PMID:26369486

  6. Comparison of ultrasonic suture welding and traditional knot tying in a rabbit rotator cuff repair model.

    PubMed

    Nho, Shane J; Cole, Brian J; Mazzocca, Augustus D; Williams, James M; Romeo, Anthony A; Bush-Joseph, Charles A; Bach, Bernard R; Hallab, Nadim J

    2006-01-01

    The purpose of this study is to evaluate ultrasonic suture welding of monofilament suture in an animal model of rotator cuff repair with biomechanical and histologic analyses. We randomly assigned 46 shoulders in 23 rabbits to 1 of 3 treatment groups: sham-operated (n = 15), knotted (n = 15), and welded (n = 16). Supraspinatus defects were surgically created and acutely repaired with suture anchors loaded with either No. 2-0 Ethibond for knotted group or No. 2-0 nylon for welded shoulders. Eighteen weeks postoperatively, all animals were killed, and the shoulders underwent either biomechanical testing or histologic analysis. The maximum stress of the sham-operated group (20.6 N/mm2) was significantly greater than that of both the knotted (10.2 N/mm2) and welded (8.3 N/mm2) groups (P < .05), but no differences were observed between the knotted and welded groups. Although some histologic changes were noted, none was considered to be significant to distinguish either group.

  7. Nylon-muscle-actuated robotic finger

    NASA Astrophysics Data System (ADS)

    Wu, Lianjun; Jung de Andrade, Monica; Rome, Richard S.; Haines, Carter; Lima, Marcio D.; Baughman, Ray H.; Tadesse, Yonas

    2015-04-01

    This paper describes the design and experimental analysis of novel artificial muscles, made of twisted and coiled nylon fibers, for powering a biomimetic robotic hand. The design is based on circulating hot and cold water to actuate the artificial muscles and obtain fast finger movements. The actuation system consists of a spring and a coiled muscle within a compliant silicone tube. The silicone tube provides a watertight, expansible compartment within which the coiled muscle contracts when heated and expands when cooled. The fabrication and characterization of the actuating system are discussed in detail. The performance of the coiled muscle fiber in embedded conditions and the related characteristics of the actuated robotic finger are described.

  8. Moisture dependence of positron annihilation spectra in nylon-6

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; St. Clair, T. L.; Holt, W. H.; Mock, W., Jr.

    1984-01-01

    Positron annihilation time spectra have been measured in nylon-6 samples as a function of their moisture content. The measured average long life component lifetime values are: 1722 + or - 47 ps (dry), 1676 + or - 40 ps (14.6 percent saturation value), 1719 + or - 26 ps (29.3 percent saturation value), 1720 + or - 35 ps (50 percent of saturation value), 1857 + or - 35 ps (78.1 percent saturation value), and 1936 + or - 57 ps (saturated). It appears that nylon-6 has a special affinity for water at low concentration levels where H2O molecules enter between the (C = O - H-N) chemical bonds between nylon molecular chains. As the water concentration increases beyond a critical level, nylon-6 specimens start trapping H2O molecules in other bond sites or potential wells. The trapped water increases the free volume in the test specimens and reduces Ps atom formation as well as its subsequent decay rate.

  9. Crystal structures and properties of nylon polymers from theory

    SciTech Connect

    Dasgupta, S.; Goddard, W.A. III; Hammond, W.B.

    1996-12-11

    A complete force field (MSXX) for simulation of all nylon polymers is derived from ab initio quantum calculations. Special emphasis is given to the accuracy of the hydrogen bond potential for the amide unit and the torsional potential between the peptide and alkane fragments. The MSXX force field was used to predict the structures, moduli, and detailed geometries of all nine nylons for which there are experimental crystal data plus one other. For nylon-(2n) with 2n = 6, the {alpha} crystal structure (with all-trans CH{sub 2} chains nearly coplanar with the hydrogen bonding plane) is more stable, while for 2n > 6, {gamma} (with the alkane plane twisted by 70{degree}) is more stable. This change results from the increased importance of methylene packing interactions over H bonds for larger 2n. We find the highest Young`s modulus for nylon-7. 51 refs., 6 figs., 7 tabs.

  10. Mesh Sutured Repairs of Abdominal Wall Defects

    PubMed Central

    Lanier, Steven T.; Jordan, Sumanas W.; Miller, Kyle R.; Ali, Nada A.; Stock, Stuart R.

    2016-01-01

    Background: A new closure technique is introduced, which uses strips of macroporous polypropylene mesh as a suture for closure of abdominal wall defects due to failures of standard sutures and difficulties with planar meshes. Methods: Strips of macroporous polypropylene mesh of 2 cm width were passed through the abdominal wall and tied as simple interrupted sutures. The surgical technique and surgical outcomes are presented. Results: One hundred and seven patients underwent a mesh sutured abdominal wall closure. Seventy-six patients had preoperative hernias, and the mean hernia width by CT scan for those with scans was 9.1 cm. Forty-nine surgical fields were clean-contaminated, contaminated, or dirty. Five patients had infections within the first 30 days. Only one knot was removed as an office procedure. Mean follow-up at 234 days revealed 4 recurrent hernias. Conclusions: Mesh sutured repairs reliably appose tissue under tension using concepts of force distribution and resistance to suture pull-through. The technique reduces the amount of foreign material required in comparison to sheet meshes, and avoids the shortcomings of monofilament sutures. Mesh sutured closures seem to be tolerant of bacterial contamination with low hernia recurrence rates and have replaced our routine use of mesh sheets and bioprosthetic grafts. PMID:27757361

  11. Cellulase immobilized on modified nylon for saccharification of cellulose

    SciTech Connect

    Jain, P.; Wilkins, E.S.

    1987-01-01

    The present study deals with the immobilization of cellulase on nylon and nylon incorporated with glass. The immobilized and free enzymes were compared in terms of their yields, using untreated sawdust (yellow pine wood) and carboxymethylcellulose (CMC) as substrates, at a standard pH and temperature. Also, the sawdust was pretreated with 1% alkaline hydrogen peroxide and the yield compared with the untreated sawdust hydrolysis to determine the importance of the substrate pretreatment.

  12. Mesenchymal stem cell-coated sutures enhance collagen depositions in sutured tissues.

    PubMed

    Casado, Javier G; Blazquez, Rebeca; Jorge, Inmaculada; Alvarez, Veronica; Gomez-Mauricio, Guadalupe; Ortega-Muñoz, Mariano; Vazquez, Jesus; Sanchez-Margallo, Francisco M

    2014-01-01

    Sutures are commonly used for surgical procedures and new sutures are being developed to improve wound healing. In the past decade, it has been extensively shown that mesenchymal stem cells (MSCs) have a wound healing potential. To benefit the overall wound healing process, we aimed to analyze the usage of pretreated sutures for improving the implantation of MSCs in the tissues. Our results firstly showed that suture pretreatments with gelatin, poly-L-lysine, and NaOH improved the adhesive strength of MSCs to sutures. These cells remained surrounding the sutured tissue and no significant phenotypic changes were found in those cells cultured onto pretreated sutures. In vivo experiments showed that the implantation of MSCs by suturing increases the collagen content in the sutured tissue. Moreover, proteomics analysis of secreted proteins showed that collagen alpha-1(I) chain was the most abundant collagen found. To our knowledge, this is the first report that aimed to improve the implantation of MSCs in tissue by suture pretreatments. Moreover, in vivo experiments suggest that MSC-coated sutures may enhance wound healing and tissue remodeling through the release of different collagen types being applicable for those patients that tend to have difficulty healing.

  13. Modified arthroscopic suture fixation of displaced tibial eminence fractures using a suture loop transporter.

    PubMed

    Yip, D K; Wong, J W; Chien, E P; Chan, C F

    2001-01-01

    Current arthroscopic suture fixation techniques of tibial eminence fractures are time consuming and the number of anchor sutures that can be placed is limited by the cumbersome and repetitive numerous needle threading steps. This occurs at 2 stages: first, when placing anchoring sutures through the avulsed anterior cruciate ligament stump with a suture punch, and second, when there is a need to traverse the tibial bone canal with the suture ends. We describe a modification that reduces the reliance on conventional rigid instruments and instead uses a loop transporter made from readily available suture material. The suture loop transporter being malleable reduces the necessary width of the tibial bone canal to be made and has a further advantage of minimizing the bone loss during the reaming of the bone tunnel. The subsequent potential for a stress fracture at these tunnel sites is also substantially reduced. Our technique is more user friendly, more accurate, and quicker to perform.

  14. Postoperative washing of sutured wounds.

    PubMed

    Harrison, Conrad; Wade, Cian; Gore, Sinclair

    2016-11-01

    A best evidence topic was written according to the structured protocol. The three part question addressed was: [In patients undergoing closure of surgical wounds with sutures] does [keeping the wound dry for the first 48 h after closure] [reduce the incidence of surgical site infections (SSIs)]? 4 relevant papers were culled from the literature and appraised. The authors, date, country, population, study type, main outcomes, key results and study weaknesses were tabulated. Current NICE guidelines recommend cleaning surgical wounds with sterile saline only for the first 48 h following skin closure. We found no evidence that washing wounds with tap water during this period increases the incidence of SSIs compared to keeping them dry. Further randomised controlled trials will enable the construction of conclusive systematic reviews and meta-analyses. PMID:27668079

  15. The double loop mattress suture

    PubMed Central

    Biddlestone, John; Samuel, Madan; Creagh, Terry; Ahmad, Tariq

    2014-01-01

    An interrupted stitch type with favorable tissue characteristics will reduce local wound complications. We describe a novel high-strength, low-tension repair for the interrupted closure of skin, cartilage, and muscle, the double loop mattress stitch, and compare it experimentally with other interrupted closure methods. The performance of the double loop mattress technique in porcine cartilage and skeletal muscle is compared with the simple, mattress, and loop mattress interrupted sutures in both a novel porcine loading chamber and mechanical model. Wound apposition is assessed by electron microscopy. The performance of the double loop mattress in vivo was confirmed using a series of 805 pediatric laparotomies/laparoscopies. The double loop mattress suture is 3.5 times stronger than the loop mattress in muscle and 1.6 times stronger in cartilage (p ≤ 0.001). Additionally, the double loop mattress reduces tissue tension by 66% compared with just 53% for the loop mattress (p ≤ 0.001). Wound gapping is equal, and wound eversion appears significantly improved (p ≤ 0.001) compared with the loop mattress in vitro. In vivo, the double loop mattress performs as well as the loop mattress and significantly better than the mattress stitch in assessments of wound eversion and dehiscence. There were no episodes of stitch extrusion in our series of patients. The mechanical advantage of its intrinsic pulley arrangement gives the double loop mattress its favorable properties. Wound dehiscence is reduced because this stitch type is stronger and exerts less tension on the tissue than the mattress stitch. We advocate the use of this novel stitch wherever a high-strength, low-tension repair is required. These properties will enhance wound repair, and its application will be useful to surgeons of all disciplines. PMID:24698436

  16. CXCL12/CXCR4 axis regulates neovascularization and lymphangiogenesis in sutured corneas in mice.

    PubMed

    Du, Ling-Ling; Liu, Ping

    2016-06-01

    The present study aimed to determine the plausible functional role of chemokine (C‑X‑C motif) ligand 12 (CXCL12/chemokine (C‑X‑C motif) receptor 4 (CXCR4) in inflammatory corneal hemangiogenesis and lymphangiogenesis in vivo. Corneal hemangiogenesis and lymphangiogenesis were induced by placing an 11‑0 nylon suture in an intrastromal position. The expression levels of the vascular endothelial growth factor (VEGF) family, CXCL12 and CXCR4 in the corneas were investigated in the corneas using reverse transcription‑quantitative polymerase chain reaction and immunohistochemistry. Corneal hemangiogenic and lymphangiogenic responses were assessed by immunofluorescence using specific antibodies against cluster of differentiation 31 and lymphatic vessel endothelial hyaluronan receptor‑1. Subconjunctival injection of AMD3100 to the sutured corneas was also performed. CXCL12/CXCR4 mRNA and protein expression levels increased markedly in suture‑induced corneal neovascularization (CNV) and decreased with AMD3100 treatment. Hemangiogenesis and lymphangiogenesis were captured in images using immunofluorescence and were shown to be markedly increased with suture placement and reduced with AMD3100 treatment. VEGF‑A/VEGFR‑1 and VEGF‑C/VEGFR‑3 mRNA expression levels were upregulated in the suture placement and control groups, whereas the expression levels of all the factors were downregulated in the AMD3100 treatment group. The results from the present study demonstrated that CXCL12/CXCR4 interactions regulate hemangiogenesis and lymphangiogenesis in suture‑induced CNV. AMD3100 may be a novel therapeutic target for the prevention of blindness. PMID:27121088

  17. Three-dimensional Structure of Nylon Hydrolase and Mechanism of Nylon-6 Hydrolysis*

    PubMed Central

    Negoro, Seiji; Shibata, Naoki; Tanaka, Yusuke; Yasuhira, Kengo; Shibata, Hiroshi; Hashimoto, Haruka; Lee, Young-Ho; Oshima, Shohei; Santa, Ryuji; Oshima, Shohei; Mochiji, Kozo; Goto, Yuji; Ikegami, Takahisa; Nagai, Keisuke; Kato, Dai-ichiro; Takeo, Masahiro; Higuchi, Yoshiki

    2012-01-01

    We performed x-ray crystallographic analyses of the 6-aminohexanoate oligomer hydrolase (NylC) from Agromyces sp. at 2.0 Å-resolution. This enzyme is a member of the N-terminal nucleophile hydrolase superfamily that is responsible for the degradation of the nylon-6 industry byproduct. We observed four identical heterodimers (27 kDa + 9 kDa), which resulted from the autoprocessing of the precursor protein (36 kDa) and which constitute the doughnut-shaped quaternary structure. The catalytic residue of NylC was identified as the N-terminal Thr-267 of the 9-kDa subunit. Furthermore, each heterodimer is folded into a single domain, generating a stacked αββα core structure. Amino acid mutations at subunit interfaces of the tetramer were observed to drastically alter the thermostability of the protein. In particular, four mutations (D122G/H130Y/D36A/E263Q) of wild-type NylC from Arthrobacter sp. (plasmid pOAD2-encoding enzyme), with a heat denaturation temperature of Tm = 52 °C, enhanced the protein thermostability by 36 °C (Tm = 88 °C), whereas a single mutation (G111S or L137A) decreased the stability by ∼10 °C. We examined the enzymatic hydrolysis of nylon-6 by the thermostable NylC mutant. Argon cluster secondary ion mass spectrometry analyses of the reaction products revealed that the major peak of nylon-6 (m/z 10,000–25,000) shifted to a smaller range, producing a new peak corresponding to m/z 1500–3000 after the enzyme treatment at 60 °C. In addition, smaller fragments in the soluble fraction were successively hydrolyzed to dimers and monomers. Based on these data, we propose that NylC should be designated as nylon hydrolase (or nylonase). Three potential uses of NylC for industrial and environmental applications are also discussed. PMID:22187439

  18. The Constrained Crystallization of Nylon-6

    NASA Astrophysics Data System (ADS)

    Mohan, Anushree; Tonelli, Alan

    2008-10-01

    Non-covalently bonded crystalline inclusion compounds (ICs) have been formed by threading host cyclic starches, cyclodextrins (CDs) onto guest nylon 6 (N6) chains. When excess N6 is employed, non-stoichiometric (n-s)-N6-CD-ICs with partially uncovered and dangling N6 chains result. While the crystalline CD lattice is stable to ˜300 C, the uncovered and dangling, yet constrained, N6 chains may crystallize below or, as shown below, be molten above ˜225 C. We have been studying the constrained crystallization of the dangling N6 chains in (n-S)-N6-CD-ICs, with comparison to bulk N6 samples, as a function of N6 molecular weights, lengths of uncovered N6 chains, and the CD host used. In the IC channels formed with host α- and γ-CDs containing 6 and 8 glucose units, respectively, single and pairs of side-by-side N6 chains are threaded and included. In the α-CD-ICs the ˜ 0.5 nm channels are separated by ˜ 1.4 nm, while in γ-CD-ICs the ˜ 1 nm channels are ˜ 1.7 nm apart, with each γ-CD channel including 2 N6 chains. N6 chains in the bulk and in the dense (n-s)-N6-CD-IC brushes show distinctly different kinetic and thermodynamic crystallization behaviors.

  19. [100 cases of bronchial mechanical sutures].

    PubMed

    Paolini, A; Lepore, M; Riccardelli, F; Canuti, W; Caminiti, A; Mucci, M; Ruggieri, M

    1990-03-01

    The Authors report their experience with stapler model T.A. 30 in lung resections; 100 stapled sutures were carried out in the IV Surgical Department of the University "La Sapienza" of Rome, during the period 1980-88. The use of stapler with two rows of staples allows a secure closure of the bronchial stump. Moreover, it prevents granulomas caused by suture material. The bronchopleural fistulas, serious complications of manual suturing, did not occur. Finally, this method is simpler and rapidly feasible in comparison with classic ones.

  20. Investigation of sulfonated aromatic compound (SAC) modification to nylon film. 2. Study of SAC sorption isotherm and atomic force microscopic characterization of nylon surfaces

    SciTech Connect

    Zhang, J.; Watson, B.A.; Keown, R.W.; Malone, C.P.; Barteau, M.A.

    1995-08-01

    Nylon 6 and nylon 66 films have been treated with aqueous sulfonated aromatic compound (SAC) solutions at concentrations ranging from 0.005 to 1.0 wt%. SAC uptakes at different treatment concentrations were measured and found to follow a BET isotherm. The surface morphologies of nylon film samples, including the original and SAC-treated films, have been characterized by atomic force microscopy (AFM). For untreated nylon 6 and nylon 66 films, AFM images show a randomly distributed fibrillar surface structure. Characteristic widths of fibrils in the nylon 66 and 6 films were 150-225 and 75-150 nm, respectively. For SAC-treated nylon films, the AFM images revealed that the surfaces of the films became covered with nodule-like features having a diameter range of 25-60 nm. AFM analysis provides evidence that SAC treatment deposited a surface coating on nylon films. AFM images of SAC-treated nylon films suggest a mechanism for stain resistance in which the SAC first forms a thin coating on the nylon via bondings between attractive groups in the SAC and nylon polymers. After treatment at increased SAC concentration, the surface is covered with nodule-like deposits which likely serve as a physical barrier to dye permeation. 20 refs., 8 figs.

  1. Treatment of Suture-related Complications of Buried-suture Double-eyelid Blepharoplasty in Asians

    PubMed Central

    2016-01-01

    Background: Double-eyelid blepharoplasty is a popular aesthetic surgery in Asians. However, the buried suture technique is associated with complications related to implantation of the suture thread. The present study was performed to identify optimal surgical suture removal techniques in Japanese patients with suture-related complications after buried suture double-eyelid blepharoplasty. Methods: This retrospective study included 210 upper eyelids of 116 consecutive Japanese patients who had undergone buried suture double-eyelid blepharoplasty at other clinics. All patients underwent suture removal surgery at the author's institution for treatment of suture-related complications. Although 12 patients (10.3%) underwent suture removal surgery alone, 104 (89.7%) underwent secondary double-eyelid blepharoplasty. The outcomes of 3 techniques were evaluated: the small skin incision method, the full skin incision method, and the conjunctival method. Results: The small skin incision method was performed in 46 patients, the full skin incision method in 63, and the conjunctival method in 7. The success rate of the full skin incision method was significantly higher than that of the small skin incision method (4.8% vs 37.0%, respectively; p < 0.0001). Patients with an uncomfortable pulling sensation exhibited a linear scar or depressive deformity without inflammation of the tarsal plate and impingement on the subconjunctival capillary vessels of the tarsal plate or a depressive deformity of the levator muscle. Patients with corneal irritation exhibited chronic inflammation of the conjunctival surface of the tarsal plate. Conclusions: Suture-related complications of buried suture double-eyelid blepharoplasty in Asians must be treated with suture removal surgery. The full skin incision method is more reliable than the small incision method for such patients.

  2. Treatment of Suture-related Complications of Buried-suture Double-eyelid Blepharoplasty in Asians

    PubMed Central

    2016-01-01

    Background: Double-eyelid blepharoplasty is a popular aesthetic surgery in Asians. However, the buried suture technique is associated with complications related to implantation of the suture thread. The present study was performed to identify optimal surgical suture removal techniques in Japanese patients with suture-related complications after buried suture double-eyelid blepharoplasty. Methods: This retrospective study included 210 upper eyelids of 116 consecutive Japanese patients who had undergone buried suture double-eyelid blepharoplasty at other clinics. All patients underwent suture removal surgery at the author's institution for treatment of suture-related complications. Although 12 patients (10.3%) underwent suture removal surgery alone, 104 (89.7%) underwent secondary double-eyelid blepharoplasty. The outcomes of 3 techniques were evaluated: the small skin incision method, the full skin incision method, and the conjunctival method. Results: The small skin incision method was performed in 46 patients, the full skin incision method in 63, and the conjunctival method in 7. The success rate of the full skin incision method was significantly higher than that of the small skin incision method (4.8% vs 37.0%, respectively; p < 0.0001). Patients with an uncomfortable pulling sensation exhibited a linear scar or depressive deformity without inflammation of the tarsal plate and impingement on the subconjunctival capillary vessels of the tarsal plate or a depressive deformity of the levator muscle. Patients with corneal irritation exhibited chronic inflammation of the conjunctival surface of the tarsal plate. Conclusions: Suture-related complications of buried suture double-eyelid blepharoplasty in Asians must be treated with suture removal surgery. The full skin incision method is more reliable than the small incision method for such patients. PMID:27622107

  3. Generalized Ferroelectricity in the Mesomorphic Phase of Nylon Polymers

    NASA Astrophysics Data System (ADS)

    Zhang, Zhongbo; Zhu, Lei; Litt, Morton

    Novel ferroelectric polymers, featured by narrow electric displacement-electric (D-E) hysteresis loop, are attractive for electric energy storage applications due to their high dielectric constant and low loss property. Currently, only poly(vinylidene fluoride) (PVDF)-based copolymers (e-beamed) and terpolymers show novel ferroelectric behavior. It is desired to achieve novel ferroelectricity in other polymers such as nylons by carefully modifying the chemical and crystal structures. In this presentation, isomorphic crystals are successfully achieved by copolymerization of nylon 11 and nylon 12 with different compositions. In this way, both chemical and structural defects (i.e., dangling amide groups and kinked bonds) are introduced into the mesomorphic phase. As a consequence, hydrogen bonding interaction is successfully weakened and thus enhanced ferroelectricity with higher maximum polarization and better polarizability is obtained. In addition, for the purpose of further disturbing the mesomorphic phase and pinning effect, partially methylated nylon copolymers are synthesized. With the help of N-methylation of amide groups, the methylated nylon copolymers show relatively narrow hysteresis loops, suggesting the pinning effect from the N-methylated amide moieties.

  4. Chitin butyrate coated electrospun nylon-6 fibers for biomedical applications

    NASA Astrophysics Data System (ADS)

    Pant, Hem Raj; Kim, Han Joo; Bhatt, Lok Ranjan; Joshi, Mahesh Kumar; Kim, Eun Kyo; Kim, Jeong In; Abdal-hay, Abdalla; Hui, K. S.; Kim, Cheol Sang

    2013-11-01

    In this study, we describe the preparation and characterizations of chitin butyrate (CB) coated nylon-6 nanofibers using single-spinneret electrospinning of blends solution. The physicochemical properties of nylon-6 composite fibers with different proportions of CB to nylon-6 were determined using FE-SEM, TEM, FT-IR spectroscopy, and water contact angle measurement. FE-SEM and TEM images revealed that the nylon-6 and CB were immiscible in the as-spun nanofibers, and phase separated nanofiber morphology becomes more pronounced with increasing amounts of CB. The bone formation ability of composite fibers was evaluated by incubating in biomimetic simulated body fluid. In order to assay the cytocompatibility and cell behavior on the composite scaffolds, osteoblast cells were seeded on the matrix. Results suggest that the deposition of CB layer on the surface of nylon-6 could increase its cell compatibility and bone formation ability. Therefore, as-synthesized nanocomposite fibrous mat has great potentiality in hard tissue engineering.

  5. Degradation of Nylon-6/Clay Nanocomposites in NO(x)

    NASA Astrophysics Data System (ADS)

    Shelley, J. S.; Devries, K. L.

    2000-04-01

    Nylon-6 is an important engineering polymer that, in its fully spherulitic (bulk) form, has many applications in gears, rollers, and other long life cycle components. In 1993, Toyota commercialized a nylon-6/clay nanocomposite out of which it produced the timing belt cover for the 1993 Camry. Although these hybrid nanocomposites show significant improvements in their mechanical response characteristics, including yield strength and heat distortion temperature, little is known about the degradation of these properties due to environmental pollutants like NOx. Nylon-6 fibers are severely degraded by interaction with NOx and other pollutants, showing a strong synergism between applied load and environmental degradation. While the nanocomposites show a significant reduction in permeability of gases and water due to the incorporation of lamellar clay, their susceptibility to non-diffusional mechano-chemical degradation is unknown. The fracture toughness of these nylon-6/day nanocomposites increases, not as a function of clay content, but as a function of the volume of nylon-6 polymer chains influenced by the clay lamellar surfaces. Both the clay and the constrained volume offer the nanocomposites some protection from the deleterious effects of NOx. The time-to-failure at a given stress intensity factor as a function of clay content and constrained volume will be discussed along with fracture toughness of the materials.

  6. 21 CFR 882.4650 - Neurosurgical suture needle.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Neurosurgical suture needle. 882.4650 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle. (a) Identification. A neurosurgical suture needle is a needle used in suturing during...

  7. 21 CFR 882.4650 - Neurosurgical suture needle.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Neurosurgical suture needle. 882.4650 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle. (a) Identification. A neurosurgical suture needle is a needle used in suturing during...

  8. 21 CFR 882.4650 - Neurosurgical suture needle.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Neurosurgical suture needle. 882.4650 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle. (a) Identification. A neurosurgical suture needle is a needle used in suturing during...

  9. 21 CFR 882.4650 - Neurosurgical suture needle.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Neurosurgical suture needle. 882.4650 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle. (a) Identification. A neurosurgical suture needle is a needle used in suturing during...

  10. 21 CFR 882.4650 - Neurosurgical suture needle.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Neurosurgical suture needle. 882.4650 Section 882...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4650 Neurosurgical suture needle. (a) Identification. A neurosurgical suture needle is a needle used in suturing during...

  11. Laceration - sutures or staples - at home

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000498.htm Laceration - sutures or staples - at home To use the ... features on this page, please enable JavaScript. A laceration is a cut that goes all the way ...

  12. Single suture customized loop for large iridodialysis repair

    PubMed Central

    Omar Yousif, Mohamed

    2016-01-01

    Managing large iridodialysis that may occur during phacoemulsification is challenging. I describe how a procedure to reposit a prolapsed iris while the anterior chamber is markedly inflated by a current of infusion fluid may inadvertently lead to large iridodialysis, and discuss how to avoid such a complication. I describe a fast and efficient technique for managing large iridodialysis both immediately, once it occurs, or as a secondary maneuver. My technique involved fixing the iris periphery back to its root at the anterior chamber angle using 10-0 polypropylene suture with two straight needles introduced directly through the cornea at distant points, and an insulin syringe as a guide track to a point 1.5 mm from the limbus at the base of a triangular scleral flap that was designed to be centered on the area of iridodialysis. I confirmed the simplicity, efficacy, and safety of my technique through a 1-year follow-up period. PMID:27729765

  13. Multilayer deformation planarization by substrate pit suturing.

    PubMed

    Chai, Yingjie; Zhu, Meiping; Xing, Huanbin; Wang, Hu; Cui, Yun; Shao, Jianda

    2016-08-01

    In the pursuit of 1064 nm high-power laser resistance dielectric coatings in the nanosecond region, a group of HfO2/SiO2 high reflectors with and without suture layers were prepared on prearranged fused silica substrates with femtosecond laser pits. Surface morphology, global coating stress, and high-resolution cross sections were characterized to determine the effects of substrate pit suturing. Laser-induced damage resistance was investigated for samples with and without suture layers. Our results indicate considerable stability in terms of the nanosecond 1064 nm laser-induced damage threshold for samples having a suture layer, due to decreased electronic field (e-field) deformation with simultaneous elimination of internal cracks. In addition, a suture layer formed by plasma ion-assisted deposition could effectively improve global mechanical stress of the coatings. By effectively reducing the multilayer deformation using a suture layer, electron-beam high-reflective coatings, whose laser-induced damage resistance was not influenced by the substrate pit, can be prepared. PMID:27472579

  14. Immobilization of enzyme on dimethyl-aminated nylon gels

    SciTech Connect

    Miyama, H.; Kawate, M.; Nosaka, Y.

    1985-10-01

    Miyama and co-workers have reported that dimethyl-aminated Nylon is a good material for the immobilization of enzyme after being quaternized. Also, they found a good correlation between the apparent Michaelis constant of the immobilized enzyme and the diffusion constant of the substrate in the matrix, and that between activity of the immobilized enzyme and interfacial free energy of the matrix. In their experiments, Nylon films of low degree of dimethylamination were used. In the present study, dimethylaminated Nylon of high degree of dimethylamination was quaternized by cationic oligomers having two functional groups. Thus, hydrogels were obtained, where the degree of cross-linking and the density of cation could be varied by changing the feeding amount and the length of cross-linking oligomers. These gels were then tested for the immobilization of urease and glucose oxidase. 9 references.

  15. Testing of SRS and RFETS Nylon Bag Material

    SciTech Connect

    Laurinat, J.E.

    1998-11-03

    This report compares the effects of radiation and heating on nylon bagout materials used at the Savannah River Site (SRS) and the Rocky Flats Environmental Technology Site (RFETS). Recently, to simplify the processing of sand, slag, and crucible (SS and C), FB-Line has replaced the low-density polyethylene (LDPE) and polyvinyl chloride (PVC) bags normally used to package cans of plutonium-bearing material with nylon bags. LDPE and PVC are not soluble in the nitric acid dissolver solution used in F-Canyon, so cans bagged using these materials had to be repackaged before they were added to the dissolver. Because nylon dissolves in nitric acid, cans bagged in nylon can be charged to the F-Canyon dissolvers without repackaging, thereby reducing handling requirements and personnel exposure. As part of a program to process RFETS SS and C at SRS, RFETS has also begun to use a nylon bagout material. The RFETS bag materials is made from a copolymer of nylon 6 and nylon 6.9, while the SRS material is made from a nylon 6 monomer. In addition, the SRS nylon has an anti-static agent added. The RFETS nylon is slightly softer than the SRS nylon, but does not appear to be as resistant to flex cracks initiated by contact with sharp corners of the inner can containing the SS and C.2 FB-Line Operations has asked for measurement of the effects of radiation and heating on these materials. Specifically, they have requested a comparison of the material properties of the plastics before and after irradiation, a measurement of the amount of outgassing when the plastics are heated, and a calculation of the amount of radiolytic gas generation. Testing was performed on samples taken from material that is currently used in FB-Line (color coded orange) and at RFETS. The requested tests are the same tests previously performed on the original and replacement nylon and LDPE bag materials.3,4,5. To evaluate the effect of irradiation on material properties, tensile stresses and elongations to break

  16. Discrimination of nylon polymers using attenuated total reflection mid-infrared spectra and multivariate statistical techniques.

    PubMed

    Enlow, Elizabeth M; Kennedy, Jennifer L; Nieuwland, Alexander A; Hendrix, James E; Morgan, Stephen L

    2005-08-01

    Nylons are an important class of synthetic polymers, from an industrial, as well as forensic, perspective. A spectroscopic method, such as Fourier transform infrared (FT-IR) spectroscopy, is necessary to determine the nylon subclasses (e. g., nylon 6 or nylon 6,6). Library searching using absolute difference and absolute derivative difference algorithms gives inconsistent results for identifying nylon subclasses. The objective of this study was to evaluate the usefulness of peak ratio analysis and multivariate statistics for the identification of nylon subclasses using attenuated total reflection (ATR) spectral data. Many nylon subclasses could not be distinguished by the peak ratio of the N-H vibrational stretch to the sp(3) C-H(2) vibrational stretch intensities. Linear discriminant analysis, however, provided a graphical visualization of differences between nylon subclasses and was able to correctly classify a set of 270 spectra from eight different subclasses with 98.5% cross-validated accuracy.

  17. Shear lag sutures: Improved suture repair through the use of adhesives.

    PubMed

    Linderman, Stephen W; Kormpakis, Ioannis; Gelberman, Richard H; Birman, Victor; Wegst, Ulrike G K; Genin, Guy M; Thomopoulos, Stavros

    2015-09-01

    Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model. PMID:26022966

  18. Shear lag sutures: Improved suture repair through the use of adhesives

    PubMed Central

    Linderman, Stephen W.; Kormpakis, Ioannis; Gelberman, Richard H.; Birman, Victor; Wegst, Ulrike G. K.; Genin, Guy M.; Thomopoulos, Stavros

    2015-01-01

    Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model. PMID:26022966

  19. Functional implications of squamosal suture size in paranthropus boisei.

    PubMed

    Dzialo, Christine; Wood, Sarah A; Berthaume, Michael; Smith, Amanda; Dumont, Elizabeth R; Benazzi, Stefano; Weber, Gerhard W; Strait, David S; Grosse, Ian R

    2014-02-01

    It has been hypothesized that the extensively overlapping temporal and parietal bones of the squamosal sutures in Paranthropus boisei are adaptations for withstanding loads associated with feeding. Finite element analysis (FEA) was used to investigate the biomechanical effects of suture size (i.e., the area of overlap between the temporal and parietal bones) on stress, strain energy, and strain ratio in the squamosal sutures of Pan troglodytes and P. boisei (specimen OH 5) during biting. Finite element models (FEMs) of OH 5 and a P. troglodytes cranium were constructed from CT scans. These models contain sutures that approximate the actual suture sizes preserved in both crania. The FEM of Pan was then modified to create two additional FEMs with squamosal sutures that are 50% smaller and 25% larger than those in the original model. Comparisons among the models test the effect of suture size on the structural integrity of the squamosal suture as the temporal squama and parietal bone move relative to each other during simulated premolar biting. Results indicate that with increasing suture size there is a decreased risk of suture failure, and that maximum stress values in the OH 5 suture were favorable compared to values in the Pan model with the normal suture size. Strain ratios suggest that shear is an important strain regime in the squamosal suture. This study is consistent with the hypothesis that larger sutures help reduce the likelihood of suture failure under high biting loads. PMID:24242913

  20. Nylon Sleeve for Cavity Amplifier Holds Tuning Despite Heat

    NASA Technical Reports Server (NTRS)

    Derr, Lloyd

    1964-01-01

    The problem: Detuning of cavity amplifiers with change in temperature. This results in deterioration of the performance of the amplifier at its design frequency. In cavity amplifiers and filters it is desirable that constant performance be maintained regardless of thermal changes. These changes often cause an "off resonance shift" in a cavity filter and a deterioration of performance in a cavity amplifier. The solution: Mount the tuning probe in a nylon sleeve. Thermal expansion and contraction of the nylon nullifies unwanted capacitive and inductive changes in the resonant elements.

  1. Electrospun nylon 6 microfiltration membrane for treatment of brewery wastewater

    NASA Astrophysics Data System (ADS)

    Islam, Md. Shahidul; Sultana, Sormin; Rahaman, Md. Saifur

    2016-07-01

    Nylon 6 microfiltration membrane, for the treatment of brewery wastewater, was fabricated using an electrospinning technique, followed by hot-pressing. The fabricated membrane was robust and demonstrated highly hydrophilic property (water contact angle 39° at the touching point to the membrane surface and the water droplet was completely immersed into the membrane in 7 seconds), and higher porosity (65%) with pore sizes of 100 to 210 nm. The electrospun nylon 6 membrane showed higher pure water flux (850 LMH) at an applied pressure of 4 psi. The same membrane also demonstrated a 95% rejection rate of suspended solids (SS) in brewery wastewater treatment.

  2. Electrospun fiber and cast films produced using zein blends with nylon-6

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Blends of zein and nylon-6 (55k) were used to produce electrospun fibers and solution cast films. Zein was blended with nylon-6 in formic acid solution. When the amount of nylon-6 was 8% or less a compatible blend formed. The blend was determined to be compatible based on physical property measureme...

  3. Pediatric Coronal Suture Fiber Alignment and the Effect of Interdigitation on Coronal Suture Mechanical Properties.

    PubMed

    Adamski, Kelly Nicole; Loyd, Andre Matthew; Samost, Albert; Myers, Barry; Nightingale, Roger; Smith, Kathleen; 'Dale' Bass, Cameron R

    2015-09-01

    The morphological and mechanical properties of the pediatric skull are important in understanding pediatric head injury biomechanics. Although previous studies have analyzed the morphology of cranial sutures, none has done so in pediatric specimens nor have previous studies related the morphology to mechanical properties of human sutures. This study quantified the geometry of pediatric cranial sutures and investigated its correlation with the suture mechanical properties. First, the suture fiber alignment was quantified using histological analysis for four ages-neonate, 9 months-old, 11 months-old, and 18 months-old. For the morphometric investigation of the suture interdigitation, suture samples from a 6-year-old were scanned using micro-CT and the level of interdigitation was measured using two techniques. The first technique, the sinuosity index, was calculated by dividing the suture path along the surface of the skull by the suture distance from beginning to end. The second technique, the surface area interdigitation index, was calculated by measuring the surface area of the bone interface outlining the suture and dividing it by the cross-sectional area of the bone. The mechanical properties were obtained using methods reported in Davis et al.6. The results of the histological analysis showed a significant increase in fiber alignment in older specimen; where random fiber alignment has an average angle deviation of 45°, neonatal suture fibers have an average deviation of 32.2° and the 18-month-old fibers had an average deviation of 16.2° (p < 0.0001). For the suture index measurements, only the sinuosity was positively correlated with the ultimate strain (R (2) = 0.62, Bonferroni corrected p = 0.011) but no other measurements showed a significant relationship, including the amount of interdigitation and elastic modulus. Our results demonstrate that there is a distinct developmental progression of the suture fiber alignment at a young age, but the

  4. The history and evolution of sutures in pelvic surgery

    PubMed Central

    Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D

    2011-01-01

    Summary The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool. PMID:21357979

  5. Fourier technique for studying ammonoid sutures

    SciTech Connect

    Gildner, R.F.; Ackerly, S.C.

    1985-01-01

    Suture patterns have long been recognized as being of primary importance in the study of ammonoids. The authors have developed a technique to use Fourier analysis to study these structures by using a simple transformation: x-y data of a digitized suture are transformed to angle of slope versus position along the suture's length. A Fast Fourier Transform applied to the data produces a power spectrum (amplitude versus wave number) providing a precise and accurate measure of suture shape. The authors have applied this technique to the analysis of ontogenetic change in suture morphology. In goniatitic, ceratitic and preadult ammonitic patterns most of the change is exhibited in the amplitudes of the lowest ten wave numbers. Their Fourier coefficients clearly show trends not readily apparent by visual inspection. The more complex ammonitic patterns are reflected in increased amplitudes of higher wave numbers (a broader peak of the power spectrum) and their analysis is necessarily more complex. The Fourier approach presents the opportunity to quantitatively measure and describe the tempo and mode of evolution in the Ammonoidea. Potential applications of the new technique, as well as limitations, are discussed with special attention to investigations of ammonoid ontogeny and phylogeny.

  6. The cell biology of suturing tendons.

    PubMed

    Wong, J K F; Alyouha, S; Kadler, K E; Ferguson, M W J; McGrouther, D A

    2010-07-01

    Trauma by suturing tendon form areas devoid of cells termed "acellular zones" in the matrix. This study aimed to characterise the cellular insult of suturing and acellular zone formation in mouse tendon. Acellular zone formation was evaluated using single grasping sutures placed using flexor tendons with time lapse cell viability imaging for a period of 12h. Both tension and injury were required to induce cell death and cell movement in the formation of the acellular zone. DNA fragmentation studies and transmission electron microscopy indicated that cells necrosed. Parallel in vivo studies showed that cell-to-cell contacts were disrupted following grasping by the suture in tensioned tendon. Without tension, cell death was lessened and cell-to-cell contacts remained intact. Quantitative immunohistochemistry and 3D cellular profile mapping of wound healing markers over a one year time course showed that acellular zones arise rapidly and showed no evidence of healing whilst the wound healing response occurred in the surrounding tissues. The acellular zones were also evident in a standard modified "Kessler" clinical repair. In conclusion, the suture repair of injured tendons produces acellular zones, which may potentially cause early tendon failure. PMID:20600895

  7. Nylon shock absorber prevents injury to parachute jumpers

    NASA Technical Reports Server (NTRS)

    Mandel, J. A.

    1966-01-01

    Nylon shock absorbers reduce the canopy-opening shock of a parachute to a level that protects the wearer from injury. A shock absorber is mounted on each of the four risers between the shroud lines and the harness. Because of their size and location, they pose no problem in repacking the chute and harness after a jump.

  8. Carpet Specifiers Guide. Ultron, Advanced Generation Nylon Carpet Fiber.

    ERIC Educational Resources Information Center

    Monsanto Textiles Co., Atlanta, GA.

    The purpose of this guide is to assist specifiers in properly specifying carpet made of Monsanto Ultron advanced generation nylon fiber. The guide describes a variety of conditions that should be considered in arriving at the proper selection and provides reference information and data, ranging from varying regulatory requirements, performance and…

  9. Endoscopic navigation for minimally invasive suturing.

    PubMed

    Wengert, Christian; Bossard, Lukas; Häberling, Armin; Baur, Charles; Székely, Gábor; Cattin, Philippe C

    2007-01-01

    Manipulating small objects such as needles, screws or plates inside the human body during minimally invasive surgery can be very difficult for less experienced surgeons, due to the loss of 3D depth perception. This paper presents an approach for tracking a suturing needle using a standard endoscope. The resulting pose information of the needle is then used to generate artificial 3D cues on the 2D screen to optimally support surgeons during tissue suturing. Additionally, if an external tracking device is provided to report the endoscope's position, the suturing needle can be tracked in a hybrid fashion with sub-millimeter accuracy. Finally, a visual navigation aid can be incorporated, if a 3D surface is intraoperatively reconstructed from video or registered from preoperative imaging. PMID:18044620

  10. Endoscopic navigation for minimally invasive suturing.

    PubMed

    Wengert, Christian; Bossard, Lukas; Häberling, Armin; Baur, Charles; Székely, Gábor; Cattin, Philippe C

    2007-01-01

    Manipulating small objects such as needles, screws or plates inside the human body during minimally invasive surgery can be very difficult for less experienced surgeons, due to the loss of 3D depth perception. This paper presents an approach for tracking a suturing needle using a standard endoscope. The resulting pose information of the needle is then used to generate artificial 3D cues on the 2D screen to optimally support surgeons during tissue suturing. Additionally, if an external tracking device is provided to report the endoscope's position, the suturing needle can be tracked in a hybrid fashion with sub-millimeter accuracy. Finally, a visual navigation aid can be incorporated, if a 3D surface is intraoperatively reconstructed from video or registered from preoperative imaging.

  11. Isolating Suture Slippage During Cadaveric Testing of Knotless Anchors.

    PubMed

    Klinge, Stephen A; Vopat, Bryan G; Paller, David; Avery, Anthony L; Koruprolu, Sarath; Fadale, Paul D

    2015-07-01

    We evaluated a testing method designed to isolate and analyze the effectiveness of different suture-retention mechanisms in knotless suture anchors used for rotator cuff repairs. Six knotless PushLock implants (Arthrex) with a suture-retention mechanism dependent on a press-fit of suture between the anchor's outer diameter and surrounding bone were compared with 6 ReelX STT devices (Stryker) reliant on an intrinsic suture-locking mechanism. Suture slippage beyond minimal clinical failure thresholds, as well as ultimate failure load, were determined with a novel testing fixture that isolated suture slippage. Suture slippage was isolated from anchor-bone disengagement. Each PushLock exhibited suture slippage of more than 3 mm, and each ReelX exhibited slippage of less than 3 mm. The PushLock implants also exhibited significantly (P < .05) more interval and maximum slippage; 5 of these 6 implants failed via complete suture slippage before dynamic testing could be completed. All ReelX devices survived dynamic testing and ultimately failed via suture breakage. This novel axial load biomechanical testing technique isolated suture slippage in 2 uniquely designed knotless anchors. The press-fit PushLock implant was prone to slippage failure, whereas the ReelX device with its internal suture-locking mechanism exhibited minimal slippage. PMID:26161766

  12. Suture needles in Oral Surgery: Alterations depending on the type and number of sutures

    PubMed Central

    Barranco-Piedra, Sebastian; Rodríguez-Caballero, Angela; Serrera-Figallo, María-Angeles; Segura-Egea, Juan-José; Gutiérrez-Pérez, José-Luis

    2012-01-01

    This study examined whether the number and type of sutures used in oral surgery influence two ad hoc variables (incision plane and displaced area), which are two variables related to whether the suture needle is suitable for the task. Seventy-five TB-15 needles were studied, which were used to suture between zero and three mucosa and/subperiosteal sutures, producing 15 groups with 5 needles in each one. The incision plane and displaced area were measured for each group, which are two variables related to how the needle has worn and altered. Statistical treatment was conducted using the Kruskal-Wallis H test to compare multiple values and the Mann-Whitney U test to compare pairs. A multi-stage regression model was applied with the aim of predicting the changes in the dependent variables based on the number and type of sutures performed. The incision plane ranged from 126.67 to 346.24μm among the different groups. The displaced area was measured as being between 14 524.83μm² and 128 311.91μm². The best predictive model for the incision plane obtained a coefficient of determination (R2) of 0.149, while it reached 0.249 for the displaced area. Subperiosteal sutures held more weighting among the variables studied. Mucosal sutures did not seem to greatly affect needle wear. Observations reported in this paper indicate that the needle should be changed after having performed two subperiosteal sutures, given the wear and change to the incision plane that is produced, which causes the needle’s cutting ability to reduce. Key words: Needles, sutures, material testing, oral surgery, third molar, scanning electron microscope. PMID:22157669

  13. Optimal Suturing Technique and Number of Sutures for Surgical Implantation of Acoustic Transmitters in Juvenile Salmonids

    SciTech Connect

    Deters, Katherine A.; Brown, Richard S.; Boyd, James W.; Eppard, M. B.; Seaburg, Adam

    2012-01-02

    The size reduction of acoustic transmitters has led to a reduction in the length of incision needed to implant a transmitter. Smaller suture knot profiles and fewer sutures may be adequate for closing an incision used to surgically implant an acoustic microtransmitter. As a result, faster surgery times and reduced tissue trauma could lead to increased survival and decreased infection for implanted fish. The objective of this study was to assess the effects of five suturing techniques on mortality, tag and suture retention, incision openness, ulceration, and redness in juvenile Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Suturing was performed by three surgeons, and study fish were held at two water temperatures (12°C and 17°C). Mortality was low and tag retention was high for all treatments on all examination days (7, 14, 21, and 28 days post-surgery). Because there was surgeon variation in suture retention among treatments, further analyses included only the one surgeon who received feedback training in all suturing techniques. Incision openness and tissue redness did not differ among treatments. The only difference observed among treatments was in tissue ulceration. Incisions closed with a horizontal mattress pattern had more ulceration than other treatments among fish held for 28 days at 17°C. Results from this study suggest that one simple interrupted 1 × 1 × 1 × 1 suture is adequate for closing incisions on fish under most circumstances. However, in dynamic environments, two simple interrupted 1 × 1 × 1 × 1 sutures should provide adequate incision closure. Reducing bias in survival and behavior tagging studies is important when making comparisons to the migrating salmon population. Therefore, by minimizing the effects of tagging on juvenile salmon (reduced tissue trauma and reduced surgery time), researchers can more accurately estimate survival and behavior.

  14. Use of Barbed Sutures in Laparoscopic Gastrointestinal Single-Layer Sutures

    PubMed Central

    Kaji, Masahide; Kinoshita, Jun; Shimizu, Koichi

    2016-01-01

    Background and Objectives: Laparoscopic anastomotic methods are not commonly used because of the cumbersome laparoscopic intracorporeal sutures and tying involved. The barbed suture is one of the various devices developed to simplify the placement of intracorporeal sutures. However, barbed sutures are not commonly used during reconstruction after radical gastrectomy in cancer patients or for single-layer entire-thickness running suturing for intestinal anastomoses. We describe the procedure for using barbed sutures and report on the short-term surgical outcomes. Methods: Between August 2012 and March 2014, 15-cm-long barbed sutures (V-Loc 180; Covidien, Mansfield, MA, USA) were used for laparoscopic intestinal anastomoses, including intestinal hole closure for esophagojejunal and gastrojejunal anastomoses after mechanical anastomoses and gastric wall closure after partial resection. Results: In total, 38 patients underwent 40 laparoscopic anastomoses (esophagojejunostomies, 26; gastrojejunostomies, 7; and simple closure of gastric defect, 7); no cases required conversion to open surgery. Two cases exhibited positive air leak test results during surgery (1 case of esophagojejunostomy and 1 case of simple closure of gastric defect). Two cases of intestinal obstruction were noted; of those, one patient with postoperative intestinal paresis (grade II) was managed conservatively, and the other underwent repeat laparoscopic surgery (grade IIIb) for internal herniation unrelated to V-Loc use. No postoperative complications at the anastomosis site and no surgery-related deaths were noted. Conclusion: Single-layer entire-thickness running suturing with the V-Loc 180 barbed suture after stapled side-to-side intestinal anastomosis was found to be safe and feasible in the reported cases. PMID:27493467

  15. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... benefits to volunteers in the Civil Air Patrol (5 U.S.C. 8141), members of the Reserve Officers' Training... 20 Employees' Benefits 1 2010-04-01 2010-04-01 false What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT...

  16. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... benefits to volunteers in the Civil Air Patrol (5 U.S.C. 8141), members of the Reserve Officers' Training... 20 Employees' Benefits 1 2014-04-01 2012-04-01 true What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT...

  17. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... benefits to volunteers in the Civil Air Patrol (5 U.S.C. 8141), members of the Reserve Officers' Training... 20 Employees' Benefits 1 2013-04-01 2012-04-01 true What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT...

  18. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... benefits to volunteers in the Civil Air Patrol (5 U.S.C. 8141), members of the Reserve Officers' Training... 20 Employees' Benefits 1 2012-04-01 2012-04-01 false What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT...

  19. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... benefits to volunteers in the Civil Air Patrol (5 U.S.C. 8141), members of the Reserve Officers' Training... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT...

  20. Tissue welding for corneal wound suture with a CW 1.9-um diode laser: an in-vivo preliminary study

    NASA Astrophysics Data System (ADS)

    Desmettre, Thomas; Mordon, Serge R.; Mitchell, Valerie A.

    1996-01-01

    This study aimed to evaluate the interest of a 1.9 micrometer diode laser for corneal wound suture. Six adult albino rabbits were anesthetized. A 7 mm corneal incision was practiced on the right eye. For 3 animals (laser plus stitch) the incision was surgically sutured with 2 stitches of a nylon monofilament and laser impacts were performed between the stitches. For 3 animals (laser only) juxtaposed lasers impacts were realized to suture the wound. After the procedure the animals were examined daily for signs of inflammation, infection and for healing of the corneal wound. Material was obtained for histological examination 1 month after the procedure. Approximation of the edges of the would was successfully obtained in the (laser plus stitch) group. In the (laser only) group this approximation remained troublesome. After the procedure, one cornea of the (laser only) group disclosed a little leakage during 2 days. Histological examination assessed the welding of the corneal wound in the two groups provided structural modifications and some inflammatory signs. Corneal welding using a 1.9 micrometer diode laser is possible either with laser and stitch or with laser only. The approximation of the edges of the wound with additional stitches is an evident drawback. The use of additional stitches should be avoided to keep the theoretical advantages of corneal would suture using laser welding.

  1. Advances in Suture Material for Obstetric and Gynecologic Surgery

    PubMed Central

    Greenberg, James A; Clark, Rachel M

    2009-01-01

    Despite millennia of experience with wound closure biomaterials, no study or surgeon has yet identified the perfect suture for all situations. Tissue characteristics, tensile strength, reactivity, absorption rates, and handling properties should be taken into account when selecting a wound closure suture. This review discusses the wound healing process and the biomechanical properties of currently available suture materials to better understand how to choose suture material in obstetrics and gynecology. PMID:19826572

  2. Bone cement improves suture anchor fixation.

    PubMed

    Giori, Nicholas J; Sohn, David H; Mirza, Faisal M; Lindsey, Derek P; Lee, Arthur T

    2006-10-01

    Suture anchor fixation failure can occur if the anchor pulls out of bone. We hypothesized that suture anchor fixation can be augmented with polymethylmethacrylate cement, and that polymethylmethacrylate can be used to improve fixation in a stripped anchor hole. Six matched cadaveric proximal humeri were used. On one side, suture anchors were placed and loaded to failure using a ramped cyclic loading protocol. The stripped anchor holes then were injected with approximately 1 cc polymethylmethacrylate, and anchors were replaced and tested again. In the contralateral humerus, polymethylmethacrylate was injected into anchor holes before anchor placement and testing. In unstripped anchors, polymethylmethacrylate increased the number of cycles to failure by 34% and failure load by 71% compared with anchors not augmented with polymethylmethacrylate. Polymethylmethacrylate haugmentation of stripped anchors increased the cycles to failure by 31% and failure load by 111% compared with unstripped uncemented anchors. No difference was found in cycles to failure or failure load between cemented stripped anchors and cemented unstripped anchors. Polymethylmethacrylate can be used to augment fixation, reducing the risk of anchor pull-out failure, regardless whether the suture anchor hole is stripped or unstripped. PMID:16702922

  3. Polyamides based on the renewable monomer, 1,13-tridecane diamine II: Synthesis and characterization of nylon 13,6

    DOE PAGES

    Samanta, Satyabrata; He, Jie; Selvakumar, Sermadurai; Lattimer, Jessica; Ulven, Chad; Sibi, Mukund; Bahr, James; Chisholm, Bret J.

    2012-12-19

    The nylon 13,6 was successfully synthesized and its chemical composition, thermal properties, crystal structure, and moisture absorption characterized. Melting temperature and glass transition temperature were determined to be 206 °C and 60 °C, respectively, while the equilibrium melting temperature was determined to be 248 °C. Characterization of the crystallization kinetics showed that nylon 13,6 exhibits very fast crystallization compared to the industrially important nylons, nylon 6 and nylon 6,6. Additionally, the moisture absorption of nylon 13,6 was dramatically lower than nylon 6 and nylon 6,6 which is consistent with the much lower amide content of nylon 13,6. The crystal structuremore » was determined to be different from the expected γ-form, which possess a pseudohexagonal unit cell. Instead, the x-ray scattering pattern was more similar to the α-form. Furthermore, a similar result has been obtained for other odd–even nylons including nylon 5,6, nylon 5,10, nylon 9,2, nylon 11,10, and nylon 11,12.« less

  4. Polyamides based on the renewable monomer, 1,13-tridecane diamine II: Synthesis and characterization of nylon 13,6

    SciTech Connect

    Samanta, Satyabrata; He, Jie; Selvakumar, Sermadurai; Lattimer, Jessica; Ulven, Chad; Sibi, Mukund; Bahr, James; Chisholm, Bret J.

    2012-12-19

    The nylon 13,6 was successfully synthesized and its chemical composition, thermal properties, crystal structure, and moisture absorption characterized. Melting temperature and glass transition temperature were determined to be 206 °C and 60 °C, respectively, while the equilibrium melting temperature was determined to be 248 °C. Characterization of the crystallization kinetics showed that nylon 13,6 exhibits very fast crystallization compared to the industrially important nylons, nylon 6 and nylon 6,6. Additionally, the moisture absorption of nylon 13,6 was dramatically lower than nylon 6 and nylon 6,6 which is consistent with the much lower amide content of nylon 13,6. The crystal structure was determined to be different from the expected γ-form, which possess a pseudohexagonal unit cell. Instead, the x-ray scattering pattern was more similar to the α-form. Furthermore, a similar result has been obtained for other odd–even nylons including nylon 5,6, nylon 5,10, nylon 9,2, nylon 11,10, and nylon 11,12.

  5. 21 CFR 870.3460 - Endovascular Suturing System.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to...

  6. 21 CFR 870.3460 - Endovascular Suturing System.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Endovascular Suturing System. 870.3460 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Prosthetic Devices § 870.3460 Endovascular Suturing System. (a) Identification. An endovascular suturing system is a medical device intended to...

  7. Biomechanical Dynamics of Cranial Sutures during Simulated Impulsive Loading

    PubMed Central

    Zhang, Z. Q.; Yang, J. L.

    2015-01-01

    Background. Cranial sutures are deformable joints between the bones of the skull, bridged by collagen fibres. They function to hold the bones of the skull together while allowing for mechanical stress transmission and deformation. Objective. The aim of this study is to investigate how cranial suture morphology, suture material property, and the arrangement of sutural collagen fibres influence the dynamic responses of the suture and surrounding bone under impulsive loads. Methods. An idealized bone-suture-bone complex was analyzed using a two-dimensional finite element model. A uniform impulsive loading was applied to the complex. Outcome variables of von Mises stress and strain energy were evaluated to characterize the sutures' biomechanical behavior. Results. Parametric studies revealed that the suture strain energy and the patterns of Mises stress in both the suture and surrounding bone were strongly dependent on the suture morphologies. Conclusions. It was concluded that the higher order hierarchical suture morphology, lower suture elastic modulus, and the better collagen fiber orientation must benefit the stress attenuation and energy absorption. PMID:27019589

  8. Repair of quadriceps tendon ruptures using suture anchors.

    PubMed

    Richards, David P; Barber, F Alan

    2002-01-01

    The repair of ruptured quadriceps tendon is commonly performed by weaving sutures through the ruptured tendon and then attaching the tendon to the bone by passing these sutures through tunnels in the superior patella. This technical note is the first report we are aware of in the English language literature of a technique that uses suture anchors to attach the tendon to bone.

  9. Effect of pasteurization, high-pressure processing, and retorting on the barrier properties of nylon 6, nylon 6/ethylene vinyl alcohol, and nylon 6/nanocomposites films.

    PubMed

    Halim, L; Pascall, M A; Lee, J; Finnigan, B

    2009-01-01

    This study determined the impact of pasteurization, high-pressure processing (HPP), and retorting on the barrier properties of nylon 6 (N6), nylon 6/ethylene vinyl alcohol (N6/EVOH), and nylon 6/nanocomposite (N6/nano) materials. The pasteurized and high-pressure treated films were coextruded with low-density polyethylene (PE) as the heat-sealing layer. The retorted films were coextruded with polypropylene (PP). Oxygen transmission rate (OTR) and water vapor transmission rate (WVTR) of the samples were measured after pasteurization (75 degrees C for 30 min), HPP (800 MPa for 10 min at 70 degrees C), and retorting (121 degrees C for 30 min) treatments. These were compared with the thermal characteristics and morphologies of the samples using differential scanning calorimetry (DSC) and X-ray diffraction (XRD). Results showed that OTR of N6 and N6/Nano increased after HPP (16.9% and 39.7%), pasteurization (13.3% and 75.9%), and retorting (63.3% and 112.6%), respectively. For N6/EVOH, a decrease in OTR after HPP (53.9%) and pasteurization (44.5%) was observed. The HPP treatment increased the WVTR of N6 (21.0%), N6/EVOH (48.9%), and N6/Nano (21.2%). The WVTR of N6, N6/EVOH, and N6/Nano increased by 96.7%, 43.8%, and 40.7%, respectively, after pasteurization. The DSC analyses showed that the enthalpy and percent crystallinity increased (2.3% to 6.5%) in the N6/Nano when compared with the N6 material after each treatment. Retorting caused a decrease (3.5%) in the percent crystallinity of the polypropylene material. HPP did not cause major morphological changes to the samples. Results of the barrier studies were influenced by the crystallinity changes in the materials as seen in the XRD diffractograms.

  10. Recycling Suture Limbs from Knotless Suture Anchors for Arthroscopic Shoulder Stabilization

    PubMed Central

    Johnson, Timothy S.; DiPompeo, Christine M.; Ismaeli, Zahra C.; Porter, Polly A.; Nicholson, Shannon L.; Johnson, David C.

    2014-01-01

    Recurrent shoulder instability often leads to labral abnormality that requires surgical intervention that may require fixation with suture anchors. The proposed surgical technique allows the surgeon to achieve 2 points of fixation around the labrum and/or capsule with a single suture secured to the glenoid with a knotless anchor. Instead of cutting and discarding the residual suture limbs after anchor insertion, this technique uses the residual suture limbs of the knotless anchor for a second suture pass. This technique (1) creates a more cost- and time-efficient surgical procedure than using multiple single-loaded anchors or double-loaded anchors, (2) decreases the known risk of glenoid fracture from the stress riser at the implant tips of multi-anchor repairs by reducing the number of anchors required for stabilization, (3) decreases the surgical time compared with the use of double-loaded anchors through simpler suture management and less knot tying, (4) allows for the secure reapproximation of the labrum to the glenoid while offering a convenient option for capsulorrhaphy without the need to insert another anchor, and (5) yields more points of soft-tissue fixation with fewer anchors drilled into the glenoid. PMID:25126504

  11. Nylon-sputtered nanoparticles: fabrication and basic properties

    NASA Astrophysics Data System (ADS)

    Polonskyi, O.; Kylián, O.; Solař, P.; Artemenko, A.; Kousal, J.; Slavínská, D.; Choukourov, A.; Biederman, H.

    2012-12-01

    Nylon-sputtered nanoparticles were prepared using a simple gas aggregation cluster source based on a planar magnetron (Haberland type) and equipped with a nylon target. Plasma polymer particles originated in an aggregation chamber and travelled to a main (deposition) chamber with a gas flow through an orifice. The deposited nanoparticles were observed to have a cauliflower-like structure. The nanoparticles were found to be nitrogen-rich with N/C ratio close to 0.5. An increase in rf power from 60 to 100 W resulted in a decrease in mean particle size from 210 to 168 nm whereas an increase in their residence time in the cluster source from 0.7 to 4.6 s resulted in an increase in the size from 73 to 231 nm.

  12. Ingress of water into solid nylon 6.6

    NASA Astrophysics Data System (ADS)

    Mansfield, P.; Bowtell, R.; Blackband, S.

    The ingress of water into Nylon 6.6 has been studied over a range of temperatures by nuclear magnetic resonance imaging techniques. The results have been used to extract the translational diffusion coefficient as a function of water concentration for various temperatures. These results in turn allow the activation energies to be evaluated. Other experiments have been made to measure the spin relaxation times T1 and T2. The results are interpreted using a two-phase exchange model from which good agreement for both the diffusion and relaxation-time data is obtained. High-pressure diffusion results also presented support the view that water is taken up preferentially at the amorphous amide sites in the Nylon and that pressure increases serve to force water onto sitccupied sites and/or onto occupied sites, giving up to three waters per amide site.

  13. Summary of aging effects on 25-year old nylon parachutes

    SciTech Connect

    Tadios, E.L.

    1988-01-01

    Structural evaluations were conducted on several parachute systems to determine the effects of aging on parachute materials. Most of the parachutes were 25 years old. Five 64 ft parachutes were evaluated along with one 4 ft guide surface parachute and three 16.5 ft ribbon parachutes. The parachute systems used in the study were all fabricated from nylon materials. Results were obtained for several material properties such as tensile strength, air permeability and melting point. Military specifications were used as zero-time data base due to lack of raw material data. The results indicate that over a period of about 25 years, parachute nylon materials do not degrade to unacceptable levels. 7 refs., 2 figs., 3 tabs.

  14. Biofiltration of odorous fume emitted from recycled nylon melting operations.

    PubMed

    Chen, Kuan-Po; Chang, Hsiao-Yu; Chou, Ming-Shean

    2013-11-01

    This study aimed to develop a biofilter packed only with fern chips for the removal of odorous compounds from recycled nylon melting operations. The fern chip biofilters could avoid the shortcomings of traditional media, such as compaction, drying, and breakdown, which lead to the performance failure of the biofilters. A pilot-scale biofilter consisting of an acrylic column (14 cm2 x 120 cm height) packed with fern chips to a volume of around 19.6 L was used for the test. Experimental results indicate that oxygen- and nitrogen-containing hydrocarbons as well as paraffins were major volatile organic compounds (VOCs) emitted from thermal smelting of recycled nylon at 250 degrees C. With operation conditions of medium pH of 5.5-7.0, empty bed retention time (EBRT) of 6-12 sec, influent total hydrocarbon (THC) concentrations of 0.65-2.61 mg m(-3), and volumetric organic loading of 0.05-0.85 g m(-3) hr(-1), the fern-chip-packed biofilter with nutrients of milk, potassium dihydrogen phosphate, and glucose could achieve an overall THC removal efficiency of around 80%. Burnt odor emitted from the smelting of the recycled nylon could be eliminated by the biofilter.

  15. Kinetics for the degradation of nylon and Kevlar parachute materials

    SciTech Connect

    Auerbach, I.

    1986-01-01

    The degradation of nylon 66 and Kevlar 29 yarns at elevated temperatures and over a broad range of humidities was studied and a rate relationship developed which models the degradation and permits computation of rate constants. The degradation rates are slow initially due to the presence of an inhibitor but increase rapidly as the inhibitor is depleted. The effect of relative humidity (RH) can be very large especially at values in the 100% range. An exponential relationship exists for nylon between the rate constant and RH. Kinetic parameters were evaluated and the rate constants at 25/sup 0/C calculated. These values showed that the tensile strength of nylon 66 will remain at a safe level over a 25-year period if the humidity is maintained at the 10% range or less. Kevlar 29 is more resistant and can tolerate humidity levels in the range of 90% or less. Degradation is governed by thermal-oxidative and moisture induced mechanisms. At the very high humidities the moisture induced degradation predominates. A relationship is developed which predicts the degradation rate over a very broad range of temperatures and humidities.

  16. Development of Nylon Based FDM Filament for Rapid Tooling Application

    NASA Astrophysics Data System (ADS)

    Singh, R.; Singh, S.

    2014-04-01

    There has been critical need for development of cost effective nylon based wire to be used as feed stock filament for fused deposition modelling (FDM) machine. But hitherto, very less work has been reported for development of alternate solution of acrylonitrile butadiene styrene (ABS) based wire which is presently used in most of FDM machines. The present research work is focused on development of nylon based wire as an alternative of ABS wire (which is to be used as feedstock filament on FDM) without changing any hardware or software of machine. For the present study aluminium oxide (Al2O3) as additive in different proportion has been used with nylon fibre. Single screw extruder was used for wire preparation and wire thus produced was tested on FDM. Mechanical properties i.e. tensile strength and percentage elongation of finally developed wire have been optimized by Taguchi L9 technique. The work represented major development in reducing cost and time in rapid tooling applications.

  17. Transfascial suture in laparoscopic ventral hernia repair; friend or foe?

    PubMed

    Sahu, Diwakar; Das, Somak; Wani, Majid Rasool; Reddy, Prasanna Kumar

    2015-01-01

    'Suture hernia' is fairly a new and rare type of ventral hernia. It occurs at the site of transfascial suture, following laparoscopic ventral hernia repair (LVHR). Employment of transfascial sutures in LVHR is still debatable in contrast to tackers. Prevention of mesh migration and significant post-operative pain are the pros and cons with the use of transfascial sutures, respectively. We report an unusual case of suture hernia or transfascial hernia, which can further intensify this dispute, but at the same time will provide insight for future consensus. PMID:25883460

  18. Horizontal running mattress suture modified with intermittent simple loops.

    PubMed

    Chacon, Anna H; Shiman, Michael I; Strozier, Narissa; Zaiac, Martin N

    2013-01-01

    Using the combination of a horizontal running mattress suture with intermittent loops achieves both good eversion with the horizontal running mattress plus the ease of removal of the simple loops. This combination technique also avoids the characteristic railroad track marks that result from prolonged non-absorbable suture retention. The unique feature of our technique is the incorporation of one simple running suture after every two runs of the horizontal running mattress suture. To demonstrate its utility, we used the suturing technique on several patients and analyzed the cosmetic outcome with post-operative photographs in comparison to other suturing techniques. In summary, the combination of running horizontal mattress suture with simple intermittent loops demonstrates functional and cosmetic benefits that can be readily taught, comprehended, and employed, leading to desirable aesthetic results and wound edge eversion.

  19. Ectocranial suture fusion in primates: pattern and phylogeny.

    PubMed

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2014-03-01

    Patterns of ectocranial suture fusion among Primates are subject to species-specific variation. In this study, we used Guttman Scaling to compare modal progression of ectocranial suture fusion among Hominidae (Homo, Pan, Gorilla, and Pongo), Hylobates, and Cercopithecidae (Macaca and Papio) groups. Our hypothesis is that suture fusion patterns should reflect their evolutionary relationship. For the lateral-anterior suture sites there appear to be three major patterns of fusion, one shared by Homo-Pan-Gorilla, anterior to posterior; one shared by Pongo and Hylobates, superior to inferior; and one shared by Cercopithecidae, posterior to anterior. For the vault suture pattern, the Hominidae groups reflect the known phylogeny. The data for Hylobates and Cercopithecidae groups is less clear. The vault suture site termination pattern of Papio is similar to that reported for Gorilla and Pongo. Thus, it may be that some suture sites are under larger genetic influence for patterns of fusion, while others are influenced by environmental/biomechanic influences.

  20. Effect of suture material on platelet deposition onto prosthetic material

    SciTech Connect

    Connolly, R.; McEnroe, C.S.; Li, S.; Coleman, J.; Callow, A.D.

    1988-07-01

    Previous studies have demonstrated the importance of employing prosthetic material with minimal thrombogenicity. However, the role of different suture materials in early thrombotic events on prosthetic materials has not been examined. Experiments were designed to analyze the effects of suture on platelet graft interaction using an in vivo baboon hemocompatability screen. Indium labeled, autologous platelet deposition was determined on expanded polytetrafluoroethylene (ePTFE) containing suture lines of polypropylene (Prolene), polybutester (Novafil), and ePTFE (Gore-Tex). A significant increase in platelet deposition was noted not only at the suture line, but proximal and distal to it as well. The results were different for each of the sutures employed and suggest that the suture line may influence early platelet deposition in the perianastomotic region, not only at the suture line, but proximally and distally as well.

  1. [Dissertations 25 years after date 26. Maxillary sutural surfaces].

    PubMed

    Remmelink, H J

    2011-06-01

    In the case of growing children with a deviation in the size or position of the upper jaw orthopaedic devices are often used to direct the growth at the level of the sutures. In the PhD thesis 'The postnatal development of the human maxillary sutural surfaces', published in 1985, the orientation and macroscopic morphology of the sutural surfaces of the maxilla in children's skulls were described. The existence of premaxillomaxillary and pterygomaxillary sutures could not be demonstrated. It was observed that the maxillary sutural surfaces were mainly sagittally oriented. Some sutural surfaces became increasingly rough with age, while the majority of the surfaces remained smooth. It was concluded that advice concerning the determination of the direction of orthopaedic forces in relation to the orientation of the sutures needed revision. Subsequent systematic reviews have reported that so far little is known about the long-term stability of orthopaedic effects in orthodontics. PMID:21761798

  2. Craniofacial Sutures: Morphology, Growth, and In Vivo Masticatory Strains

    PubMed Central

    RAFFERTY, KATHERINE L.; HERRING, SUSAN W.

    2010-01-01

    The growth and morphology of craniofacial sutures are thought to reflect their functional environment. However, little is known about in vivo sutural mechanics. The present study investigates the strains experienced by the internasal, nasofrontal, and anterior interfrontal sutures during masticatory activity in 4–6-month-old miniature swine (Sus scrofa). Measurements of the bony/fibrous arrangements and growth rates of these sutures were then examined in the context of their mechanical environment. Large tensile strains were measured in the interfrontal suture (1,036 με ± 400 SD), whereas the posterior internasal suture was under moderate compression (−440 με ± 238) and the nasofrontal suture experienced large compression (−1,583 με ± 506). Sutural interdigitation was associated with compressive strain. The collagen fibers of the internasal and interfrontal sutures were clearly arranged to resist compression and tension, respectively, whereas those of the nasofrontal suture could not be readily characterized as either compression or tension resisting. The average linear rate of growth over a 1-week period at the nasofrontal suture (133.8 μm, ± 50.9 S.D) was significantly greater than that of both the internasal and interfrontal sutures (39.2 μm ± 11.4 and 65.5 μm ± 14.0, respectively). Histological observations suggest that the nasofrontal suture contains chondroid tissue, which may explain the unexpected combination of high compressive loading and rapid growth in this suture. PMID:10521876

  3. The method of manufacture of nylon dental partially removable prosthesis using additive technologies

    NASA Astrophysics Data System (ADS)

    Kashapov, R. N.; Korobkina, A. I.; Platonov, E. V.; Saleeva, G. T.

    2014-12-01

    The article is devoted to the topic of creating new methods of dental prosthesis. The aim of this work is to investigate the possibility of using additive technology to create nylon prosthesis. As a result of experimental studies, was made a sample of nylon partially removable prosthesis using 3D printing has allowed to simplify, accelerate and reduce the coat of manufacturing high-precision nylon dentures.

  4. Skin tension related to tension reduction sutures.

    PubMed

    Hwang, Kun; Kim, Han Joon; Kim, Kyung Yong; Han, Seung Ho; Hwang, Se Jin

    2015-01-01

    The aim of this study was to compare the skin tension of several fascial/subcutaneous tensile reduction sutures. Six upper limbs and 8 lower limbs of 4 fresh cadavers were used. At the deltoid area (10 cm below the palpable acromion) and lateral thigh (midpoint from the palpable greater trochanter to the lateral border of the patella), and within a 3 × 6-cm fusiform area of skin, subcutaneous tissue defects were created. At the midpoint of the defect, a no. 5 silk suture was passed through the dermis at a 5-mm margin of the defect, and the defect was approximated. The initial tension to approximate the margins was measured using a tensiometer.The tension needed to approximate skin without any tension reduction suture (S) was 6.5 ± 4.6 N (Newton). The tensions needed to approximate superficial fascia (SF) and deep fascia (DF) were 7.8 ± 3.4 N and 10.3 ± 5.1 N, respectively. The tension needed to approximate the skin after approximating the SF was 4.1 ± 3.4 N. The tension needed to approximate the skin after approximating the DF was 4.9 ± 4.0 N. The tension reduction effect of approximating the SF was 38.8 ± 16.4% (2.4 ± 1.5 N, P = 0.000 [ANOVA, Scheffé]). The tension reduction effect of approximating the DF was 25.2% ± 21.9% (1.5 ± 1.4 N, P = 0.001 [ANOVA, Scheffé]). The reason for this is thought to be that the SF is located closely to the skin unlike the DF. The results of this study might be a basis for tension reduction sutures.

  5. A century's worth of arterial sutures.

    PubMed

    Barker, W F

    1988-01-01

    In light of the advanced state of vascular surgery today, it is hard to realize that the technique of vascular suturing is barely 100 years old. Even more remarkable is the skill with which the early surgeons applied almost all of the techniques we use today. Eck's experiments in the laboratory with portal vein-to-vena caval anastomoses were followed by pessimistic predictions concerning the future of arterial sutures. Jassinowsky had just performed the first successful arterial suture when he did a clinical arterial repair and, within 15 years, Carrel had developed nearly all the technical maneuvers which we use today. Knowledge of Carrel's work spread rapidly, and practical application of his work was reflected in the development of vascular replacements, such as venous grafting, the bypass technique used for vein grafts before World War I. There was, however, a lag in further developments until the end of the forties when dos Santos and Kunlin revived old methods and opened the way for further arterial surgical advances. These early developments are well-documented, but the reasons for delaying the acceptance of their applications remain a matter for speculation. PMID:3067741

  6. High Coverages of Hydrogen on a (10,0) Carbon Nanotube

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Arnold, James (Technical Monitor)

    2001-01-01

    The binding energy of H to a (10,0) carbon nanotube is calculated at 24, 50, and 100% coverage. Several different bonding configurations are considered for the 50% coverage case. Using the ONIOM (our own n-layered integrated molecular orbital and molecular mechanics) approach, the average C-H bond energy for the most stable 50% coverage and for the 100% coverage are 57.3 and 38.6 kcal/mol, respectively. Considering the size of the bond energy of H2, these values suggest that it will be difficult to achieve 100% atomic H coverage on a (10,0) nanotube.

  7. Cranial suture biology of the Aleutian Island inhabitants.

    PubMed

    Cray, James; Mooney, Mark P; Siegel, Michael I

    2011-04-01

    Research on cranial suture biology suggests there is biological and taxonomic information to be garnered from the heritable pattern of suture synostosis. Suture synostosis along with brain growth patterns, diet, and biomechanical forces influence phenotypic variability in cranial vault morphology. This study was designed to determine the pattern of ectocranial suture synostosis in skeletal populations from the Aleutian Islands. We address the hypothesis that ectocranial suture synostosis pattern will differ according to cranial vault shape. Ales Hrdlicka identified two phenotypes in remains excavated from the Aleutian Island. The Paleo-Aleutians, exhibiting a dolichocranic phenotype with little prognathism linked to artifacts distinguished from later inhabitants, Aleutians, who exhibited a brachycranic phenotype with a greater amount of prognathism. A total of 212 crania representing Paleo-Aleuts and Aleutian as defined by Hrdlicka were investigated for suture synostosis pattern following standard methodologies. Comparisons were performed using Guttmann analyses. Results revealed similar suture fusion patterns for the Paleo-Aleut and Aleutian, a strong anterior to posterior pattern of suture fusion for the lateral-anterior suture sites, and a pattern of early termination at the sagittal suture sites for the vault. These patterns were found to differ from that reported in the literature. Because these two populations with distinct cranial shapes exhibit similar patterns of suture synostosis it appears pattern is independent of cranial shape in these populations of Homo sapiens. These findings suggest that suture fusion patterns may be population dependent and that a standardized methodology, using suture fusion to determine age-at-death, may not be applicable to all populations.

  8. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial.

    PubMed

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati; Devi, Dipali; Kalita, Dhaneswar; Kalita, Kasturi; Dash, Suvakanta; Kotoky, Jibon

    2016-05-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  9. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone

    PubMed Central

    Ono, Y.; Woodmass, J. M.; Nelson, A. A.; Boorman, R. S.; Thornton, G. M.

    2016-01-01

    Objectives This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be

  10. Validation of the nylon flocked swab for planetary protection applications

    NASA Astrophysics Data System (ADS)

    Moissl-Eichinger, Christine; Probst, Alexander

    The major issue of planetary protection is to prevent the contamination of extraterrestrial en-vironments by terrestrial biomolecules and life forms. In order not to affect or even to confound future life detection missions on celestial bodies, which are of interest for their chemical and bi-ological evolution, spacecraft are constructed in clean rooms and are subject to severe cleaning processes and microbiological controls before launch. Microbiological assays are used to mea-sure and control the bioburden on spacecraft itself and spacecraft hardware during assembly. The current NASA standard assays have originally been developed for the Viking programme in the 70s. Due to the stringent contamination control constrains of the upcoming ESA Ex-oMars mission, these protocols cannot be used, in particular the application of cotton swabs with wooden applicators is no longer possible. Therefore, cotton swabs will be replaced by the novel nylon flocked swabs. In the study presented here, the nylon flocked swabs were validated for the usage for measuring and controling of the bioburden on spacecraft related surfaces. The absolute recovery efficiency was determined, following the guidelines of USP1223 in preci-sion, accuracy, robustness, specificity, linearity and limit of detection. As a standard surface, stainless steel coupons were used, whereas B. atrophaeus (spores) served as standard microbial strain. Additionally, the nylon flocked swab was used for experiments on different rough and smooth surfaces with seven different Bacillus spores and two different protocols. Further details will be given concerning the new ESA standard swab procedure for the microbial examination of flight hardware and clean rooms to be used for the upcoming ExoMars mission.

  11. Safety assessment of nylon as used in cosmetics.

    PubMed

    Burnett, Christina; Heldreth, Bart; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan

    2014-01-01

    The Cosmetic Ingredient Review Expert Panel (Panel) reviewed the safety of nylon polymers, which function in cosmetics primarily as bulking and opacifying agents. The Panel reviewed relevant animal and human data related to these large polymers and determined that they are not likely to penetrate the skin. Whatever residual monomers may be present were not present at a sufficient level to cause any reactions in test subjects at the maximum ingredient use concentration. Accordingly, the Panel concluded that these ingredients are safe in the present practices of use and concentration.

  12. Low background techniques for the Borexino nylon vessels

    SciTech Connect

    Pocar, Andrea

    2005-09-08

    Borexino is an organic liquid scintillator underground detector for low energy solar neutrinos. The experiment has to satisfy extremely stringent low background requirements. The thin nylon spherical scintillator containment vessel has to meet cleanliness and low radioactivity levels second only, within the detector, to the scintillator itself. Overall, the background from the vessel in the fiducial volume of the detector must be kept at the level of one event per day or better. The requirements, design choices, results from laboratory tests, and fabrication techniques that have been adopted to meet this goal are presented. Details of the precautions taken during the installation of the vessels inside the Borexino detector are also discussed.

  13. Mechanics of cranial sutures during simulated cyclic loading.

    PubMed

    Jasinoski, S C; Reddy, B D

    2012-07-26

    Previous computational and experimental analyses revealed that cranial sutures, fibrous joints between the bones, can reduce the strain experienced by the surrounding skull bones during mastication. This damping effect reflects the importance of including sutures in finite element (FE) analyses of the skull. Using the FE method, the behaviour of three suture morphologies of increasing complexity (butt-ended, moderate interdigitated, and complex interdigitated) during static loading was recently investigated, and the sutures were assumed to have linear elastic properties. In the current study, viscoelastic properties, derived from published experimental results of the nasofrontal suture of young pigs (Sus scrofa), are applied to the three idealised bone-suture models. The effects of suture viscoelasticity on the stress, strain, and strain energy in the models were computed for three different frequencies (corresponding to periods of 1, 10, and 100s) and compared to the results of a static, linear elastic analysis. The range of applied frequencies broadly represents different physiological activities, with the highest frequency simulating mastication and the lowest frequency simulating growth and pressure of the surrounding tissues. Comparing across all three suture morphologies, strain energy and strain in the suture decreased with the increase in suture complexity. For each suture model, the magnitude of strain decreased with an increase in frequency, and the magnitudes were similar for both the elastic and 1s frequency analyses. In addition, a viscous response is less apparent in the higher frequency analyses, indicating that viscous properties are less important to the behaviour of the suture during those analyses. The FE results suggest that implementation of viscoelastic properties may not be necessary for computational studies of skull behaviour during masticatory loading but instead might be more relevant for studies examining lower frequency physiological

  14. Development of rapid continuous dyeing process for heavy-weight nylon 6,6 carpet

    Technology Transfer Automated Retrieval System (TEKTRAN)

    An improved continuous dyeing process for coloration of heavy-weight (60-70 oz/yd2), residential nylon 6,6 carpet is reported. By inserting a slot steam applicator after the dye pad and before the box steamer to preheat the carpet to around 180°F (greater than the nylon wet glass transition temperat...

  15. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... film. 175.360 Section 175.360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND... coatings for nylon film. Vinylidene chloride copolymer coatings identified in this section and applied on nylon film may be safely used as food-contact surfaces, in accordance with the following...

  16. [The system of designation of surgical suture materials].

    PubMed

    Adamian, A A; Vinokurova, T I; Novikova, O A; Gavriliuk, N N; Sergeev, V P

    1990-12-01

    The authors suggest a unified system of designation of type--sizes of surgical suture materials of various nature and structure, which removes the existing discrepancy between the numbering of foreign and Soviet threads as well as of Soviet threads produced by different enterprises of the country. Introduction of the new system of metric sizes of the suture threads will allow surgeons to be properly orientated in the choice of the necessary suture material and make easier the work of services engaged in the development and realization of surgical suture materials. PMID:2079825

  17. Visual Measurement of Suture Strain for Robotic Surgery

    PubMed Central

    Martell, John; Elmer, Thomas; Gopalsami, Nachappa; Park, Young Soo

    2011-01-01

    Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions. PMID:21436874

  18. Heterochrony and patterns of cranial suture closure in hystricognath rodents

    PubMed Central

    Wilson, Laura A B; Sánchez-Villagra, Marcelo R

    2009-01-01

    Sutures, joints that allow one bone to articulate with another through intervening fibrous connective tissue, serve as major sites of bone expansion during postnatal craniofacial growth in the vertebrate skull and represent an aspect of cranial ontogeny which may exhibit functional and phylogenetic correlates. Suture evolution among hystricognath rodents, an ecologically diverse group represented here by 26 species, is examined using sequence heterochrony methods, i.e. event pairing and parsimov. Although minor nuances in suture closure sequence exist between species, the overall sequence was found to be conserved both across the hystricognath group and, to an increasing degree, within selected clades. At species level, suture closure pattern exhibited a significant positive correlation with patterns previously reported for hominoids. Patterns for most clades revealed the first sutures to close are those contacting the exoccipital, interparietal, and palatine bones. Heterochronic shifts were found along 19 of 35 branches within the hystricognath phylogeny. The number of shifts per node ranged from one to seven events and, overall, involved 21 of 34 suture sites. The topology generated by parsimony analyses of the event pair matrix yielded only one grouping that was congruent with the evolutionary relationships, compiled from morphological and molecular studies, taken as framework. Sutures contacting the exoccipital displayed the highest levels of most complete closure across all species. Level of suture closure is negatively correlated with cranial length (P < 0.05). Differing life history and locomotory strategies are coupled in part with differing suture closure patterns among several species. PMID:19245501

  19. Cyclic loading comparison of Bio-SutureTak-#2 FiberWire and Bio Mini-Revo-#2 Hi-Fi suture anchor-sutures in cadaveric scapulae.

    PubMed

    Sparks, Brad S; Nyland, John; Nawab, Akbar; Blackburn, Ethan; Krupp, Ryan; Burden, Robert

    2008-03-01

    This study compared tap-in Bio-SutureTak suture anchor-#2 FiberWire suture (Group 1) and screw-in Bio Mini-Revo suture anchor-#2 Hi-Fi suture (Group 2) fixation in the glenoid region of interest for Bankart repair, in addition to evaluation of isolated suture loop biomechanical properties under progressive incremental cyclic loads. With knowledge of glenoid apparent bone mineral density (BMD), implant preparation and fit characteristics, and following application of a light manual tensile load, the primary investigator scored each specimen for perceived within group biomechanical test performance using a 0-10 point modified visual analog scale. After scoring, 12 paired constructs were placed in a servo hydraulic device clamp, preloaded to 25 N, and cycled between 25 and 50 Hz with a 25 N load increase every 25 cycles. Group 2 withstood greater load (104.1 +/- 56 vs. 70 +/- 36.9 N, P = 0.04) and displaced more at failure (13 +/- 4.5 vs. 8.6 +/- 3.3 mm, P = 0.04). All Group 1 specimens failed prior to reaching 150 N, whereas 25% of Group 2 specimens (n = 3) failed at 200 N. All specimens failed by anchor pullout except for three Group 2 specimens that failed by eyelet breakage at 200 N. Isolated suture testing revealed that Group 1 sutures displaced less at each cyclic load (P = 0.028) and withstood greater failure loads (P = 0.028) than that of Group 2 sutures. Group 2 constructs displayed moderately strong relationships between perceived within group biomechanical test performance and ultimate load (r (2) = 0.55) and displacement at failure (r (2) = 0.67). Group 1 did not display significant relationships. Similar biomechanical performance between 50 and 125 N, greater load at failure, and superior biomechanical test prediction accuracy suggest that the screw-in type Bio Mini-Revo suture anchor-#2 Hi-Fi suture combination may be preferred for Bankart lesion repair in low apparent BMD glenoid processes. The #2 Hi-Fi suture, however, allowed significantly greater

  20. Evolution of Complexity in Paleozoic Ammonoid Sutures.

    PubMed

    Saunders; Work; Nikolaeva

    1999-10-22

    The septal sutures of 588 genera of Paleozoic ammonoids showed a 1600 percent increase in mean complexity over 140 million years. Within 475 ancestor/descendant pairs, descendants were more than twice as likely to be more complex than their ancestors. Twelve subclades (373 genera) averaged 34 percent increased complexity. These patterns are compatible with an active or driven system of long-term bias for increased complexity. Mass extinctions acted in opposition to this long-term trend, tending to eliminate more-complex forms and resetting the trend with each extinction event.

  1. Techniques and applications of adjustable sutures.

    PubMed

    Fells, P

    1987-02-01

    The 'rediscovery' of adjustable sutures some 10 years ago has given the ophthalmic surgeon much more confidence in his ability to correct strabismus. Three methods of use are described: during surgery under general anaesthesia with adjustment during the operation using the 'springback' test to centralise the eye; during surgery under general anaesthesia and subsequent adjustment under local anaesthesia using the patient's subjective responses to obtain optimal positioning; and performance of the operation and adjustment under topical local anaesthesia in one procedure. Full details are given of each technique and the indications for their application to particular problems are discussed. PMID:3297111

  2. Evaluation of overcharge protection life in nickel cadmium cells with non-nylon separators

    SciTech Connect

    Scoles, D.L.; Johnson, Z.W.; Hayden, J.W.; Pickett, D.F. Jr.

    1997-12-01

    Hydrogen gassing and the potential for cell rupture in aerospace nickel cadmium cells is directly related to loss of overcharge protection built into the cell during manufacturing. It is well known that cells having nylon separators contribute to this loss via a hydrolysis reaction of the nylon in the potassium hydroxide electrolyte environment in the cell. The hydrolysis reaction produces lower chain organics which are oxidized by the positive electrode and oxygen. Oxidation of the organics diminishes the overcharge protection. With introduction of the Super NiCd and the Magnum nickel cadmium cells the nylon hydrolysis reaction is eliminated, but any reducing agent in the cell such as nickel or an organic additive can contribute to loss of overcharge protection. The present effort describes analyses made to evaluate the extent of overcharge protection loss in cells which do not have nylon hydrolysis and quantifies the diminished amount of overcharge protection loss as a result of eliminating nylon from aerospace cells.

  3. Nylon coil actuator operating temperature range and stiffness

    NASA Astrophysics Data System (ADS)

    Kianzad, Soheil; Pandit, Milind; Bahi, Addie; Rafie Ravandi, Ali; Ko, Frank; Spinks, Geoffrey M.; Madden, John D. W.

    2015-04-01

    Components in automotive and aerospace applications require a wide temperature range of operation. Newly discovered thermally active Baughman muscle potentially provides affordable and viable solutions for driving mechanical devices by heating them from room temperature, but little is known about their operation below room temperature. We study the mechanical behavior of nylon coil actuators by testing elastic modulus and by investigating tensile stroke as a function of temperature. Loads that range from 35 MPa to 155 MPa were applied. For the nylon used and the coiling conditions, active thermal contraction totals 19.5 % when the temperature is raised from -40 °C to 160 °C. The thermal contraction observed from -40 °C to 20°C is only ~2 %, whereas between 100 and 160 °C the contraction is 10 %. A marked increase in thermal contraction is occurs in the vicinity of the glass transition temperature (~ 45°C). The elastic modulus drops as temperature increases, from ~155 MPa at - 40 °C to 35 MPa at 200 °C. Interestingly the drop in active contraction with increasing load is small and much less than might be expected given the temperature dependence of modulus.

  4. Metabolic Engineering toward Sustainable Production of Nylon-6.

    PubMed

    Turk, Stefan C H J; Kloosterman, Wigard P; Ninaber, Dennis K; Kolen, Karin P A M; Knutova, Julia; Suir, Erwin; Schürmann, Martin; Raemakers-Franken, Petronella C; Müller, Monika; de Wildeman, Stefaan M A; Raamsdonk, Leonie M; van der Pol, Ruud; Wu, Liang; Temudo, Margarida F; van der Hoeven, Rob A M; Akeroyd, Michiel; van der Stoel, Roland E; Noorman, Henk J; Bovenberg, Roel A L; Trefzer, Axel C

    2016-01-15

    Nylon-6 is a bulk polymer used for many applications. It consists of the non-natural building block 6-aminocaproic acid, the linear form of caprolactam. Via a retro-synthetic approach, two synthetic pathways were identified for the fermentative production of 6-aminocaproic acid. Both pathways require yet unreported novel biocatalytic steps. We demonstrated proof of these bioconversions by in vitro enzyme assays with a set of selected candidate proteins expressed in Escherichia coli. One of the biosynthetic pathways starts with 2-oxoglutarate and contains bioconversions of the ketoacid elongation pathway known from methanogenic archaea. This pathway was selected for implementation in E. coli and yielded 6-aminocaproic acid at levels up to 160 mg/L in lab-scale batch fermentations. The total amount of 6-aminocaproic acid and related intermediates generated by this pathway exceeded 2 g/L in lab-scale fed-batch fermentations, indicating its potential for further optimization toward large-scale sustainable production of nylon-6.

  5. Applications of nylon membrane arrays to gene expression analysis.

    PubMed

    Cox, J M

    2001-04-01

    Gene expression analyses by hybridization of probes derived from mRNA to cDNA targets arrayed on a nylon membranes have been performed with increasing frequency and success over the last decade. While the initial costs of generating arrays are moderately high, they are now available commercially as complete packages which include the membranes and associated image analysis software for acquisition and processing of the data. Arrays can be used to generate information concerning the expression of mRNA from cells treated with various agents or from different tissues, e.g. comparing diseased with normal controls. To date, many groups, including immunologists, have used this technology to examine gene expression within their area of biological interest. The main characteristic of these systems is the large amount of data generated, since the expression of many thousands of genes are measured in parallel. The main practical issues are sensitivity of detection, reproducibility, comparability with other systems (e.g. Northern blots) and processing of data. Some of the significant applications of nylon array technology to date are reviewed in this chapter, and with these issues in mind, we include a discussion of our own experiences in this area.

  6. Sulfide oxidation in fluidized bed bioreactor using nylon support material.

    PubMed

    Midha, Varsha; Jha, M K; Dey, Apurba

    2012-01-01

    A continuous fluidized bed bioreactor (FBBR) with nylon support particles was used to treat synthetic sulfide wastewater at different hydraulic retention time of 25, 50 and 75 min and upflow velocity of 14, 17 and 20 m/hr. The effects of upflow velocity, hydraulic retention time and reactor operation time on sulfide oxidation rate were studied using statistical model. Mixed culture obtained from the activated sludge, taken from tannery effluent treatment plant, was used as a source for microorganisms. The diameter and density of the nylon particles were 2-3 mm and 1140 kg/m3, respectively. Experiments were carried out in the reactor at a temperature of (30 +/- 2) degrees C, at a fixed bed height of 16 cm after the formation of biofilm on the surface of support particles. Biofilm thickness reached (42 +/- 3) microm after 15 days from reactor start-up. The sulfide oxidation, sulfate and sulfur formation is examined at all hydraulic retention times and upflow velocities. The results indicated that almost 90%-92% sulfide oxidation was achieved at all hydraulic retention times. Statistical model could explain 94% of the variability and analysis of variance showed that upflow velocity and hydraulic retention time slightly affected the sulfide oxidation rate. The highest sulfide oxidation of 92% with 70% sulfur was obtained at hydraulic retention time of 75 min and upflow velocity of 14 m/hr.

  7. Loss of Fine Particle Ammonium from Denuded Nylon Filters

    SciTech Connect

    Yu, Xiao-Ying; Lee, Taehyoung; Ayres, Benjamin; Kreidenweis, Sonia M.; Malm, William C.; Collett, Jeffrey L.

    2006-08-01

    Ammonium is an important constituent of fine particulate mass in the atmosphere, but can be difficult to quantify due to possible sampling artifacts. Losses of semivolatile species such as NH4NO3 can be particularly problematic. In order to evaluate ammonium losses from aerosol particles collected on filters, a series of field experiments was conducted using denuded nylon and Teflon filters at Bondville, Illinois (February 2003), San Gorgonio, California (April 2003 and July 2004), Grand Canyon National Park, Arizona (May, 2003), Brigantine, New Jersey (November 2003), and Great Smoky Mountains National Park (NP), Tennessee (July–August 2004). Samples were collected over 24-hr periods. Losses from denuded nylon filters ranged from 10% (monthly average) in Bondville, Illinois to 28% in San Gorgonio, California in summer. Losses on individual sample days ranged from 1% to 65%. Losses tended to increase with increasing diurnal temperature and relative humidity changes and with the fraction of ambient total N(--III) (particulate NH4+ plus gaseous NH3) present as gaseous NH3. The amount of ammonium lost at most sites could be explained by the amount of NH4NO3 present in the sampled aerosol. Ammonium losses at Great Smoky Mountains NP, however, significantly exceeded the amount of NH4NO3 collected. Ammoniated organic salts are suggested as additional important contributors to observed ammonium loss at this location.

  8. Multifunctional ZnO/Nylon 6 nanofiber mats by an electrospinning– electrospraying hybrid process for use in protective applications

    Technology Transfer Automated Retrieval System (TEKTRAN)

    ZnO/Nylon 6 nanofiber mats were prepared by an electrospinning–electrospraying hybrid process in which ZnO nanoparticles were dispersed on the surface of Nylon 6 nanofibers without becoming completely embedded. The prepared ZnO/Nylon 6 nanofiber mats were evaluated for their abilities to kill bacter...

  9. Does UV disinfection compromise sutures? An evaluation of tissue response and suture retention in salmon surgically implanted with transmitters

    SciTech Connect

    Walker, Ricardo W.; Brown, Richard S.; Deters, Katherine A.; Eppard, M. B.; Cooke, Steven J.

    2013-10-01

    Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiation (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.

  10. New suture materials for midline laparotomy closure: an experimental study

    PubMed Central

    2014-01-01

    Background Midline laparotomy closure carries a significant risk of incisional hernia. This study examines the behavior of two new suture materials, an elastic material, polyurethane (PUe), and a barbed polydioxanone (PDXb) suture thread in a rabbit model of midline incision closure. Methods Three 2-cm midline incisions were made in 68 New Zealand White rabbits. The incisions were closed by running suture using four 3/0 threads: polypropylene (PP) (Surgipro®, Covidien), PUe (Assuplus®, Assut Europe), PDX (Assufil®, Assut Europe) or PDXb (Filbloc®, Assut Europe). Animals in each suture group were euthanized 3 weeks and 6 months after surgery. Histological sections of the tissue-embedded sutures were subjected to morphological, collagen expression, macrophage response and uniaxial tensiometry studies. Results No signs of wound dehiscence or complications were observed. At 3 weeks, all sutures were surrounded by connective tissue composed mainly of collagen III. PUe showed greater collagen I expression than the other sutures. All sutures elicited a macrophage response that diminished from 3 weeks to 6 months (p < 0.001). This response was similar for the non-reabsorbable sutures (PP and PUe) yet PDXb showed a significantly greater response than the other reabsorbable suture (PDX) at 3 weeks (p < 0.01). At this early time point, the tensile strength of PUe was similar to that of control intact tissue (p > 0.05). Conclusion Three weeks after surgery, PUe revealed more collagen I deposition than the remaining materials and this translated to a similar biomechanical behavior to linea alba, that could avoid the appearance of short term dehiscences and thus reduce the incidence of incisional hernia. PDXb provides no additional advantages in their behavior regarding PDX suture. PMID:25231161

  11. Interdomal Suture through a Nondelivery Endonasal Approach: A New Technique

    PubMed Central

    Leibou, Lior

    2016-01-01

    Background: The use of interdomal sutures for tip refinement is common in open rhinoplasty and in endonasal rhinoplasty using a delivery technique, but there is paucity of reports in the literature regarding the use of interdomal suturing techniques when the nondelivery endonasal approach is chosen. Objective: The authors describe a technique designed to refine the nasal tip with an interdomal suture placed through a nondelivery endonasal approach. Methods: In this study, the authors retrospectively review the cases of 45 patients who underwent endonasal rhinoplasty with the authors’ interdomal suturing technique between the years 2011 and 2013. The average age of the patients was 25.3 years. Intercrural sutures (PDS 4.0 straight needle, Cincinnati, Ohio) were placed as mattress-like suture in the tip region, with the knot buried between both alar cartilages. The suture is tightened progressively according to the tip definition and narrowing sought. Results: The patients were followed for 12 months. All of the patients demonstrated a significant reduction in lobule and tip widths. This series had only 1 complication of tip asymmetry that was revised 1 year after the initial operation. There were no cases of infection, allergic reaction, or extrusion of the suture. Conclusions: Despite the lack of a large volume of patients, our study confirms that this technique is indeed an attractive and highly predictable option for achieving adequate tip refinement and definition when using a nondelivery endonasal rhinoplasty. PMID:27622086

  12. Suture Bridge Fixation Technique for Posterior Cruciate Ligament Avulsion Fracture.

    PubMed

    Lee, Kwang Won; Yang, Dae Suk; Lee, Gyu Sang; Choy, Won Sik

    2015-12-01

    We presented a surgical technique including a suture bridge technique with relatively small incision for the reduction and fixation of posterior ligament avulsion fractures. A suture anchor was used to hold the avulsed fragment and a knotless anchor was used to continuously compress the bony fragment into the fracture site, thereby maintaining reduction during healing.

  13. Interdomal Suture through a Nondelivery Endonasal Approach: A New Technique

    PubMed Central

    Leibou, Lior

    2016-01-01

    Background: The use of interdomal sutures for tip refinement is common in open rhinoplasty and in endonasal rhinoplasty using a delivery technique, but there is paucity of reports in the literature regarding the use of interdomal suturing techniques when the nondelivery endonasal approach is chosen. Objective: The authors describe a technique designed to refine the nasal tip with an interdomal suture placed through a nondelivery endonasal approach. Methods: In this study, the authors retrospectively review the cases of 45 patients who underwent endonasal rhinoplasty with the authors’ interdomal suturing technique between the years 2011 and 2013. The average age of the patients was 25.3 years. Intercrural sutures (PDS 4.0 straight needle, Cincinnati, Ohio) were placed as mattress-like suture in the tip region, with the knot buried between both alar cartilages. The suture is tightened progressively according to the tip definition and narrowing sought. Results: The patients were followed for 12 months. All of the patients demonstrated a significant reduction in lobule and tip widths. This series had only 1 complication of tip asymmetry that was revised 1 year after the initial operation. There were no cases of infection, allergic reaction, or extrusion of the suture. Conclusions: Despite the lack of a large volume of patients, our study confirms that this technique is indeed an attractive and highly predictable option for achieving adequate tip refinement and definition when using a nondelivery endonasal rhinoplasty.

  14. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  15. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture....

  16. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture....

  17. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  18. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture....

  19. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  20. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture....

  1. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  2. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  3. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Stainless steel suture. 878.4495 Section 878.4495 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture....

  4. Cataract Section Across Temporary Stainless-Steel Sutures

    PubMed Central

    MacDonald, R. Keith

    1965-01-01

    The purpose of the technique described was to combine the advantages of a cleanedged Graefe-knife incision with those of safety and near-perfect apposition offered by preplaced sutures: a preliminary to cataract extraction. Uncuttable preplaced 2-mm. stainless steel sutures were finally replaced after completion of the incision by attached braided silk for closure purposes. PMID:14291461

  5. Structural grafts and suture techniques in functional and aesthetic rhinoplasty

    PubMed Central

    Gassner, Holger G.

    2011-01-01

    Rhinoplasty has undergone important changes. With the advent of the open structure approach, requirements for structural grafting and direct manipulation of the cartilaginous skeleton through suture techniques have increased substantially. The present review analyzes the current literature on frequently referenced structural grafts and suture techniques. Individual techniques are described and their utility is discussed in light of available studies and data. PMID:22073105

  6. Investigation of the Rigid Amorphous Fraction in Nylon-6

    SciTech Connect

    Chen,H.; Cebe, P.

    2007-01-01

    A three-phase model, comprising crystalline, mobile amorphous, and rigid amorphous fractions (X{sub c}, X{sub MA}, X{sub rA}, respectively) has been applied in the study of semicrystalline Nylon-6. The samples studied were Nylon-6 alpha phase prepared by subsequent annealing of a parent sample slowly cooled from the melt. The treated samples were annealed at 110 C, then briefly heated to 136 C, then re-annealed at 110 C. Temperature-modulated differential scanning calorimetry (TMDSC) measurements allow the devitrification of the rigid amorphous fraction to be examined. We observe a lower endotherm, termed the 'annealing' peak in the non-reversing heat flow after annealing at 110 C. By brief heating above this lower endotherm and immediately quenching in LN{sub 2}-cooled glass beads, the glass transition temperature and X{sub RA} decrease substantially, X{sub MA} increases, and the annealing peak disappears. The annealing peak corresponds to the point at which partial de-vitrification of the rigid amorphous fraction (RAF) occurs. Re-annealing at 110 C causes the glass transition and X{sub RA} to increase, and X{sub MA} to decrease. None of these treatments affected the measured degree of crystallinity, but it cannot be excluded that crystal reorganization or recrystallization may also occur at the annealing peak, contributing to the de-vitrification of the rigid amorphous fraction. Using a combined approach of thermal analysis with wide and small angle X-ray scattering, we analyze the location of the rigid amorphous and mobile amorphous fractions within the context of the Heterogeneous and Homogeneous Stack Models. Results show the homogeneous stack model is the correct one for Nylon-6. The cooperativity length ({var_epsilon}{sub A}) increases with a decrease of rigid amorphous fraction, or, increase of the mobile amorphous fraction. Devitrification of some of the RAF leads to the broadening of the glass transition region and shift of T{sub g}.

  7. The application of barbed sutures in body contouring surgery.

    PubMed

    Shermak, Michele A

    2013-09-01

    Even with the evolution of primary surgical techniques in body contouring, wound closure remains primarily traditional and has not advanced beyond the techniques followed in past decades. Streamlining wound closure would be the next advance for body contouring surgery. Absorbable barbed sutures offer a potential solution, and they are the subject of this review investigating the applications of absorbable barbed sutures in body contouring surgery. Barbed sutures hold tension as closure proceeds, theoretically decreasing the time required for wound closure, approximating dead space, and obliterating subcutaneous knots that may result in palpable, painful granulomas. Review of the literature reveals some evidence of time savings (in some cases significant and, in some, not); however, the literature also shows some wound complications from the use of barbed sutures, including infections and extrusions. Barbed sutures have not yet been conventionally embraced, and the technology will certainly continue to evolve in order to make the devices more desirable for plastic surgeons.

  8. Evaluation of Sternal Closure with Absorbable Polydioxanone Sutures in Children

    PubMed Central

    Bigdelian, Hamid; Sedighi, Mohsen

    2014-01-01

    Introduction: Sternal dehiscence, sternal wound infection and mediastinitis are troublesome complications following median sternotomy which are major causes of morbidity and mortality of patients. Synthetic polydioxanone absorbable suture seems effective in prevention of these complications in children undergoing open heart surgery. Methods: During 2 years period, 620 patients who underwent median sternotomy were studied. The efficacy of absorbable polydioxanone suture was tested on patients using figure-of-eight suture technique. The patients’ age ranged from newborn to 15 years old. All surgical interventions were performed according to a standard protocol. Results: No sternal sutures were broken during the sternal closure and no case of mediastinitis was seen. Two patients experienced sternal dehiscence (0.32%). Follow-up period of patients were established between 1 to 132 months after open heart surgery. Conclusion: Sternal closure with the polydioxanone suture in combination with figure-of-eight technique is a safe and suitable method in children with good clinical results. PMID:24753834

  9. [Costs and benefits of mechanical sutures in esophageal surgery].

    PubMed

    Peracchia, A; Bardini, R

    1990-03-01

    The cost/benefit ratio of mechanical sutures is a controversial issue. Aim of this work was to compare the cost of esophago-visceral anastomoses performed with staplers versus the cost of conventional anastomoses. Not only the cost of the material, but also the economical impact of the hospital stay and operative complications was evaluated. Results show a statistically significant decrease of morbidity in patients treated with mechanical sutures (3.7% vs 18.8%, p = 0.0001). The overall cost of a single mechanical suture was markedly lower than that of a single manual suture (934.000 vs 2,209.000 Italian lira). We conclude that a significant decrease of hospital cost can be expected using mechanical sutures. It has to be noted, however, that in order to achieve such results, an adequate surgical training with staplers is mandatory.

  10. Moisture dependence of positron annihilation spectra in nylon-6

    NASA Astrophysics Data System (ADS)

    Singh, Jag J.; Clair, Terry L. ST.; Holt, William H.; Mock, Willis

    1984-04-01

    Positron annihilation time spectra have been measured in nylon-6 specimens as a function of their moisture content. The measured average longlife component lifetime values are: 1722 ± 47 ps (dry), 1676 ± 40 ps (14.6% saturation value), 1719 ± 26 ps (29.3% saturation value), 1720 ± 35 ps (50% of saturation value), 1857 ± 35 ps (78.1% of saturation value) and 1936 ± 57 ps (saturated). It is noted that the longlife component lifetime at first decreases and then increases with increasing moisture content in the specimens. This behavior is quite different from that observed in earlier studies of various epoxy, polyamide, and polyimide materials, where the longlife components lifetime decreased linearly with increasing moisture content. The longlife component intensity on the other hand, decreases steadily as the moisture content increases from 0 to 100% of the saturation value. A possible explanation for these anomalous features is discussed.

  11. Ab initio study of semiconductor atoms impurities in zigzag edge (10,0) carbon nanotubes

    SciTech Connect

    Muttaqien, Fahdzi Suprijadi

    2015-04-16

    The substitutional impurities in zigzag edge (10,0) carbon nanotubes have been studied by using first principles calculations. Silicon (Si), gallium (Ga), and arsenic (As) atom have been chosen as semiconductor based-atom for replacing carbon atoms in CNT’s surface. The silicon atom changes the energy gap of pristine zigzag (10,0) CNT, it is 0.19 eV more narrow than that of pristine CNT. Geometrically, the silicon atom creates sp{sup 3} bond with three adjacent carbon atoms, where the tetrahedral form of its sp{sup 3} bond is consisted of free unoccupied state. The silicon atom does not induce magnetism to zigzag CNT. Due to gallium (Ga) and arsenic (As) atom substitution, the zigzag CNT becomes metallic and has magnetic moment of 1 µ{sub B}. The valance and conduction band are crossed each other, then the energy gap is vanished. The electronic properties of GaAs-doped CNT are dominantly affected by gallium atom and its magnetic properties are dominantly affected by arsenic atom. These results prove that the CNT with desired properties can be obtained with substitutional impurities without any giving structural defect.

  12. Energy efficient one-pot synthesis of durable superhydrophobic coating through nylon micro-rods

    NASA Astrophysics Data System (ADS)

    Simovich, T.; Wu, A. H.; Lamb, R. N.

    2014-03-01

    A durable and superhydrophobic coating was fabricated at room temperature through encapsulating nylon micro-rods in a hydrophobic silica shell. This was achieved through the precipitation of miniemulsified nylon under high shear to generate micro-rods with high aspect ratio in the presence of methyltrimethoxysilane. The resultant coating structure resembles a network of highly entangled micro-rods that give rise to both surface roughness and hydrophobicity, resulting in contact angles greater than 155°. The embedded nylon polymer within the micro-rods imparts significant mechanical durability to the surface, resulting in a coating hardness of 2H using the pencil hardness test.

  13. Surface modifications of nylon/carbon fiber composite for improving joint adhesion

    SciTech Connect

    Wu, R.; Liao, S.L.; Tong, T.S.; Young, J.T.

    1996-12-31

    Various methods were used to modify the nylon/carbon fiber composite surfaces, including grit blasting, flame and plasma pretreatments. The surfaces of nylon composites after pretreatments were characterized by contact angle measurements, scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS). XPS results show that several functional groups were formed after plasma and flame pretreatments. The scanning electron microscope (SEM) photographs suggest that the blasting pretreatment increased the surface roughness of nylon composites. All these surface pretreatments dramatically increased the lap shear strength if proper operation conditions were used. The reasons for the increase of lap shear strength were explained.

  14. Mesenteric suture granuloma caused by retained fragments of suture material in a girl who had a laparotomy 12 years previously.

    PubMed

    Jung, Eunyoung; Park, Woo-Hyun; Choi, Soon-Ok

    2013-01-01

    The authors report a case of a mesenteric suture granuloma in a 12 year-old-girl who had a small bowel resection for a complicated intussusception at the age of 5 months. At later exploration a whitish round tumor located on the anti-mesenteric side of the intestine was found. Several small intestinal loops also abutted on the tumor. Pathologic examination showed fibrosis and a granuloma containing linear colored braided suture material with multinucleated giant cell. As mesenteric suture granulomas have a complex appearance and mimic a soft tissue tumor during imaging, it is important for a surgeon to know about this condition and to consider the history of previous surgery when evaluating the images of patients presenting with an abdominal or pelvic mass. Suture granulomas separate from previous suture sites have not been described in the literature.

  15. Sutures in the Altaids: Implications for Continental Suturing and Growth (Invited)

    NASA Astrophysics Data System (ADS)

    Xiao, W.

    2013-12-01

    Ophiolites and melanges are remnants of vanished oceans in orogenic belts; therefore they are very important for defining sutures. However, as illustrated in the Altaids ophiolitic fragments can be formed at different tectonic settings. Some ophiolites in the Altaids may be substrate of oceanic island arcs or accreted fragments, such as those in Kazakhstan and East Junggar. Others are mainly melanges and mostly occur as blocks or slices in accretionary prisms, such as those in the southern Chinese Altay and southern Tianshan. Ages of ophiolites and melanges should be used to constrain the existence time of ancient oceans, which predate the accretionary process after their emplacement. These ophiolitic fragments or melanges do not necessarily represent real sutures. Ages of some ophiolitic fragments and melanges in Central Asia such as those in the Tianshan predate accretion/collision event and the incorporation of these ophiolitic fragments into accretionary complexes may reflect merely different phases of accretion instead of closure of a major ocean. Major oceans or real sutures can only be recognized by paleogeographical separation of typical faunas and/or floras as many orogenic systems contain archipelagos with second-hand ocean basins, a tectonic scenario similar to the present-day SE Asia. Paleomagnetic data and tectonic analysis enable us to conduct palinspastic reconstructions and can help define real sutures, such as the one in the Southern Tianshan as a main cryptic plane separating the Tarim craton to the south and the accretionary collages to the north from the late Paleozoic to the early Triassic. During most of the Paleozoic time, the Siberia Craton was distributed in the northwest and the Tarim Craton was in the southeast, while the Kazakhstan arc chain was in the west. The active margin of the Siberia Craton had wide accretionary complexes and accreted intra-oceanic arcs and terranes, the Kazakhstan arc chain was characterized by multiple

  16. The Nuclear Network Generator NETGEN v10.0: A Tool for Nuclear Astrophysics

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Goriely, S.; Jorissen, A.; Takahashi, K.; Arnould, M.

    2011-09-01

    We present an updated release of the Brussels Nuclear Network Generator. NETGEN is a tool to help astrophysicists build nuclear reaction networks by generating tables of rates of light-particle (mostly n, p, α) induced reactions, nucleus-nucleus fusion reactions, and photodisintegrations, as well as β-decays and electron captures on temperature grids specified by the user. Nuclear reaction networks relevant to a large variety of astrophysical situations can be constructed, including Big-Bang nucleosynthesis, stellar hydrostatic and explosive hydrogen-, helium- and later burning phases, as well as the synthesis of heavy nuclides (s-, r-, p-, rp-, α-processes). The latest version, NETGEN v10.0, is available on the ULB-IAA website www.astro.ulb.ac.be/Netgen/form.html.

  17. A comparison of ultrasonic suture welding and traditional knot tying.

    PubMed

    Richmond, J C

    2001-01-01

    The slippage of knots and the technical challenge of tying them securely are potential impediments to certain arthroscopic procedures. Ultrasonic energy delivered at 70 kHz can be used to weld No. 2 polypropylene suture. This method was compared with a traditional knot (surgeon's knot with four alternating half hitches) tied with an open technique to determine whether welding of sutures is comparable, in mechanical properties, to hand-tied knots. Both loops were fashioned around a 0.25-inch mandrel and then tested. The load to reach 3-mm elongation (point of likely biologic failure of a repair) was significantly greater for welded sutures than for knots. The elongation at ultimate failure was significantly less for welded sutures than for knots. The number of cycles to failure and the creep after initial displacement were similar for both welded and knotted suture loops. The ultimate load to failure was significantly greater for the knotted than for the welded suture. The welding of suture for the repair of musculoskeletal soft tissue presents an attractive alternative to traditional knot tying, particularly for arthroscopic applications.

  18. Interlocking circumareolar suture with undyed polyamide thread: a personal experience.

    PubMed

    Salgarello, Marzia; Visconti, Giuseppe; Barone-Adesi, Liliana

    2013-10-01

    In plastic breast surgery, the interlocking areolar suture has gained wide popularity since its introduction in 2007 by Hammond and colleagues. The interlocking circumareolar suture plays its role in the setting of circumareolar excisions to achieve a durable areola shaping and to prevent scar widening/hypertrophy and areola spreading/distortion. This study retrospectively reviewed 49 breasts that underwent interlocking suture after July 2011 for both aesthetic and reconstructive indications. For the suturing, 3-0 undyed polyamide thread with a straight cutting needle (Dafilon; B. Braun Melsungen AG, Melsungen, Germany) was used. This suture material was preferred to Gore-Tex reported by Hammond and colleagues because it is undyed without any microporous configuration, more wieldy, and less expensive. All 49 breasts showed good results in terms of areola shaping and diameter control as well as good scar quality during a mean follow-up period of 12 months (range 2-18 months) (Fig. 2). No infection, suture extrusion, skin fistula, or granuloma were experienced. The suture was not visible at all, and the patients did not report its palpability. However, at careful examination, the thread resulted slightly palpable.

  19. Arthroscopic coracoclavicular ligament reconstruction using biologic and suture fixation.

    PubMed

    Pennington, William T; Hergan, David J; Bartz, Brian A

    2007-07-01

    Presented in this report is a modified arthroscopic approach to acromioclavicular joint reconstruction via suture and allograft fixation. An arthroscopic approach is used to expose the base of the coracoid by use of electrocautery. After an open distal clavicle excision is performed, clavicular and coracoid tunnels are created under arthroscopic visualization as previously described by Wolf and Pennington. The myotendinous end of a semitendinosus allograft is sutured to a Spider plate (Kinetikos Medical, San Diego, CA). The tendinous end of the graft is prepared with a running baseball stitch. A Nitinol wire with a loop end (Arthrex, Naples, FL) is used to pass 2 free FiberTape sutures (Arthrex) and the leading sutures from the tendinous end of the graft through the clavicular and coracoid tunnels, exiting out the anterior portal. One of the FiberTape sutures is retrieved with a grasper and passed over the anterior aspect of the distal clavicle. The second FiberTape suture and the allograft are passed over the distal end of the resected clavicle. While the acromioclavicular joint is held reduced, the FiberTape sutures are tied to the plate and the allograft is tensioned medially until the plate is embedded against the superior surface of the clavicle. The tendinous end of the graft is secured to the superior surface of the clavicle with a Bio-tenodesis screw (Arthrex) medial to the clavicular tunnel.

  20. Measurement of the radon diffusion through a nylon foil for different air humidities

    NASA Astrophysics Data System (ADS)

    Mamedov, Fadahat; Štekl, Ivan; Smolek, Karel

    2015-08-01

    The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained results of this study with a nylon foil with the thickness of 50 µm are presented.

  1. Tough and transparent nylon-6 electrospun nanofiber reinforced melamine-formaldehyde composites.

    PubMed

    Jiang, Shaohua; Hou, Haoqing; Greiner, Andreas; Agarwal, Seema

    2012-05-01

    The use of nylon-6 electrospun nanofiber mats as reinforcement with synergistic effect in tensile strength and toughness for melamine-formaldehyde (MF) resin is highlighted in this article. Interestingly, there was a drastic effect of the wetting procedure of reinforcing fiber mat by the MF resin on the morphology and mechanical properties of the composites. The wetting of nylon fibers by passing through a solution of MF resin showed a core-shell morphology and a significant improvement in properties as compared to the dip-coating procedure for wetting of the fibers. Depending on the wt% of reinforcing nylon fiber mats, the composites could be considered as either fiber reinforced MF composites or MF glued nylon fibers.

  2. Measurement of the radon diffusion through a nylon foil for different air humidities

    SciTech Connect

    Mamedov, Fadahat; Štekl, Ivan; Smolek, Karel

    2015-08-17

    The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained results of this study with a nylon foil with the thickness of 50 µm are presented.

  3. Spatial motion constraints for robot assisted suturing using virtual fixtures.

    PubMed

    Kapoor, Ankur; Li, Ming; Taylor, Russell H

    2005-01-01

    We address the problem of the stitching task in endoscopic surgery using a circular needle under robotic assistance. Our main focus is to present an algorithm for suturing using guidance virtual fixtures (VF) that assist the surgeon to move towards a desired goal. A weighted multi-objective, constraint optimization framework is used to compute the joint motions required for the tasks. We show that with the help of VF, suturing can be performed at awkward angles without multiple trials, thus avoiding damage to tissue. In this preliminary study we show the feasibility of our approach and demonstrate the promise of cooperative assistance in complex tasks such as suturing.

  4. The Paleotethys suture in Central Iran

    NASA Astrophysics Data System (ADS)

    Bagheri, S.; Stampfli, G. M.

    2003-04-01

    The Triassic rocks of the Nakhlak area have been used to justify the hypothesis of the rotation of the Central-East Iranian microplate, mainly based on paleomagnetic data. Davoudzadeh and his coworkers (1981) pointed out the existing contrast between the Nakhlakh succession and the time-equivalent lithostratigraphic units exposed in the surrounding regions and compared them with the Triassic rocks of the Aghdarband area on the southern edge of the Turan plate. We recently gathered evidences that this part of central Iran effectively belongs to the Northern Iranian Paleo-Tethys suture zone and related Variscan terrains of the Turan plate. This is the case for the northwestern part of central Iran, where the Anarak-Khur belt (Anarak schists and their thick Cretaceous-Paleocene sedimentary cover) presents all the elements of an orogenic zone such as dismembered ophiolites and silisiclastics, calcareous and volcanic cover which has been deformed and metamorphosed. This belt is separated to the northwest from the Alborz microcontinent by the Great Kavir fault and Cretaceous ophiolite mélanges. To the southeast it is bounded by the Biabanak fault and serpentinites and the Biabanak block, part of the central-east Iranian plate. The later zone is formed by Proterozoic metamorphic basement and marine sedimentary cover, nearly continuous from the Ordovician to the Triassic, at the uppermost part upper Triassic-lower Jurassic bauxites and silisiclastics are observed. Excepted the Ordovician angular unconformities and the boundary between lower Jurassic and younger layers, this sequence displays no significant main unconformities and can be attributed to the Cimmerian super-terrain. Thus, this sequences represents the classical evolution of the southern Paleo-Tethys passive margin, as found in the Alborz microcontinent or the Band-e Bayan zone of Afghanistan and is the witness of large scale duplication of the Paleo-Tethys suture zone through major Alpine strike-slip faults

  5. Influence of electrostatic charge on the performance of 10 mm nylon cyclones

    SciTech Connect

    Briant, J.K.; Moss, O.R.

    1984-07-01

    The 10 mm nylon cyclone is commonly used for measuring the respirable aerosol concentration of airborne dust. Under some conditions the measured concentration may be lower than the actual value due to electrostatic charge. The use of a cyclone moulded from conducting, graphite-filled nylon is proposed. Tests of such a cyclone are reported. The results showed a consistency, providing a more accurate representation of deposition in the human respiratory tract.

  6. Nylon 6,6 Nonwoven Fabric Separates Oil Contaminates from Oil-in-Water Emulsions.

    PubMed

    Ortega, Ryan A; Carter, Erin S; Ortega, Albert E

    2016-01-01

    Industrial oil spills into aquatic environments can have catastrophic environmental effects. First responders to oil spills along the coast of the Gulf of Mexico in the southern United States have used spunbond nylon fabric bags and fences to separate spilled oil and oil waste from contaminated water. Low area mass density spunbond nylon is capable of sorbing more than 16 times its mass in low viscosity crude oil and more than 26 times its mass in higher viscosity gear lube oil. Nylon bags separated more than 95% of gear lube oil contaminate from a 4.5% oil-in-water emulsion. Field testing of spunbond nylon fences by oil spill first responders has demonstrated the ability of this material to contain the oily contaminate while allowing water to flow through. We hypothesize that the effectiveness of nylon as an oil filter is due to the fact that it is both more oleophilic and more hydrophilic than other commonly used oil separation materials. The nylon traps oil droplets within the fabric or on the surface, while water droplets are free to flow through the fabric to the water on the opposite side of the fabric.

  7. [Research on structure of MC-nylon 6/aramid composites by spectroanalysis method].

    PubMed

    Wang, Can-Yao; Zheng, Yu-Ying

    2008-01-01

    The Kevlar fiber, treated with toluene-2,4-diisocyanate and caprolactam, was used to reinforce MC nylon 6. XPS showed the change in chemical components and spectra after fiber was treated. IR showed that the spectra of Kevlar fiber and MC-nylon 6 were incorporated purely when they were mixed, while the treated Kevlar fiber provided the activation in the ring-opening polymerization of caprolactam, and the amide groups of graft chains could form strong hydrogen bonds with matrix. These graft chains and hydrogen bonds would contribute to improving interfacial bonding between MC-nylon 6 and Kevlar fiber. XRD indicated that the induction of Kevlar fiber had no effect on the cryastalline style of MC-nylon 6 obviously, however, the crystals had better seasonal structure. The crystals of MC-nylon 6/Kevlar fiber composites were more perfect than that of MC-nylon 6/Kevlar untreated fiber composites with the same amount of Kevlar fiber. The increase of Kevlar fiber contributed to forming perfect a spherulite when the mass concentration of Kevlar fiber was less than 2%, however, the more the Kevlar fiber, the less the content of a spherulite when the mass concentration of Kevlar fiber was more than 2%.

  8. Nylon 6,6 Nonwoven Fabric Separates Oil Contaminates from Oil-in-Water Emulsions.

    PubMed

    Ortega, Ryan A; Carter, Erin S; Ortega, Albert E

    2016-01-01

    Industrial oil spills into aquatic environments can have catastrophic environmental effects. First responders to oil spills along the coast of the Gulf of Mexico in the southern United States have used spunbond nylon fabric bags and fences to separate spilled oil and oil waste from contaminated water. Low area mass density spunbond nylon is capable of sorbing more than 16 times its mass in low viscosity crude oil and more than 26 times its mass in higher viscosity gear lube oil. Nylon bags separated more than 95% of gear lube oil contaminate from a 4.5% oil-in-water emulsion. Field testing of spunbond nylon fences by oil spill first responders has demonstrated the ability of this material to contain the oily contaminate while allowing water to flow through. We hypothesize that the effectiveness of nylon as an oil filter is due to the fact that it is both more oleophilic and more hydrophilic than other commonly used oil separation materials. The nylon traps oil droplets within the fabric or on the surface, while water droplets are free to flow through the fabric to the water on the opposite side of the fabric. PMID:27411088

  9. Nylon 6,6 Nonwoven Fabric Separates Oil Contaminates from Oil-in-Water Emulsions

    PubMed Central

    Carter, Erin S.; Ortega, Albert E.

    2016-01-01

    Industrial oil spills into aquatic environments can have catastrophic environmental effects. First responders to oil spills along the coast of the Gulf of Mexico in the southern United States have used spunbond nylon fabric bags and fences to separate spilled oil and oil waste from contaminated water. Low area mass density spunbond nylon is capable of sorbing more than 16 times its mass in low viscosity crude oil and more than 26 times its mass in higher viscosity gear lube oil. Nylon bags separated more than 95% of gear lube oil contaminate from a 4.5% oil-in-water emulsion. Field testing of spunbond nylon fences by oil spill first responders has demonstrated the ability of this material to contain the oily contaminate while allowing water to flow through. We hypothesize that the effectiveness of nylon as an oil filter is due to the fact that it is both more oleophilic and more hydrophilic than other commonly used oil separation materials. The nylon traps oil droplets within the fabric or on the surface, while water droplets are free to flow through the fabric to the water on the opposite side of the fabric. PMID:27411088

  10. Alignment of carbon nanotubes and reinforcing effects in nylon-6 polymer composite fibers

    NASA Astrophysics Data System (ADS)

    Rangari, Vijaya K.; Yousuf, Mohammed; Jeelani, Shaik; Pulikkathara, Merlyn X.; Khabashesku, Valery N.

    2008-06-01

    Alignment of pristine carbon nanotubes (P-CNTs) and fluorinated carbon nanotubes (F-CNTs) in nylon-6 polymer composite fibers (PCFs) has been achieved using a single-screw extrusion method. CNTs have been used as filler reinforcements to enhance the mechanical and thermal properties of nylon-6 composite fibers. The composites were fabricated by dry mixing nylon-6 polymer powder with the CNTs as the first step, then followed by the melt extrusion process of fiber materials in a single-screw extruder. The extruded fibers were stretched to their maxima and stabilized using a godet set-up. Finally, fibers were wound on a Wayne filament winder machine and tested for their tensile and thermal properties. The tests have shown a remarkable change in mechanical and thermal properties of nylon-6 polymer fibers with the addition of 0.5 wt% F-CNTs and 1.0 wt% of P-CNTs. To draw a comparison between the improvements achieved, the same process has been repeated with neat nylon-6 polymer. As a result, tensile strength has been increased by 230% for PCFs made with 0.5% F-CNTs and 1% P-CNTs as additives. These fibers have been further characterized by DSC, Raman spectroscopy and SEM which confirm the alignment of CNTs and interfacial bonding to nylon-6 polymer matrix.

  11. Polyvinyl alcohol {gamma}-ray grafted nylon 4 membrane for pervaporation and evapomeation

    SciTech Connect

    Lai, J.Y.; Chen, R.Y.; Lee, K.R

    1993-05-01

    Nylon 4, which possesses high mechanical strength and good affinity for water, can be considered as a liquid separation membrane. To improve the hydrophilicity of a Nylon 4 membrane for pervaporation and evapomeation processes, and to overcome the hydrolysis of polyvinyl alcohol (PVA), this study attempts to prepare a PVA-g-Nylon 4 membrane by {gamma}-ray irradiation grafting of vinyl acetate (VAc) onto Nylon 4 membrane, followed by hydrolysis treatment. The effects of down-stream pressure, irradiation dose, VAc monomer concentration, degree of grafting, feed composition, and size of alcohols on the separation of water-alcohol mixtures were studied. The surface properties of the prepared membrane were characterized by FTIR, ESCA, and a contact angle meter. A separation factor of 13.8 and a permeation rate of 0.352 kg/m{sup 2}-h can be obtained for a PVA-g-Nylon 4 membrane with a degree of grafting of 21.2% for a 90-wt% ethanol feed concentration. Compared to the pervaporation process, the evapomeation process has a significantly increased separation factor with a decreased permeation rate for the same PVA-g-Nylon 4 membrane. 24 refs., 9 figs., 4 tabs.

  12. [Mechanical anastomosis without purse-string suture in esophageal surgery].

    PubMed

    Liboni, A; Zamboni, P; Occhioni, G; Masia, S; Passerò, G; Trignano, M

    1990-03-01

    A new surgical procedure for oesophago-enterostomy using staplers without purse-string suture is described. This technique is possible only using the CEEAP stapler, thanks to its new technical features.

  13. Anatomic Hip Capsular Reconstruction With Separate Suture Anchors.

    PubMed

    Cuéllar, Ricardo; Cuéllar, Asier; Sánchez, Alberto; Cuéllar, Adrián

    2016-06-01

    The number of reports on the use of capsule suturing techniques during hip arthroscopy has increased in the last few years because of the important function played by the iliofemoral ligament (IFL). This study describes an arthroscopic technique whereby the hip capsule is opened by a limited vertical dissection of both the capsule itself and the IFL from their footprint on the acetabular rim, and the capsulolabral junction and the IFL's deep fibers are released. After the intra-articular procedure, the capsule is closed through 2 to 4 side-to-side sutures in the vertical arm of the capsulotomy and 1 to 2 suture anchors with sutures are passed through either side of the capsular confluence. This technique prevents a full transverse section of the IFL and allows complete capsular closure through reconstruction of the capsular footprint. PMID:27656393

  14. A multiphase transitioning peptide hydrogel for suturing ultrasmall vessels

    NASA Astrophysics Data System (ADS)

    Smith, Daniel J.; Brat, Gabriel A.; Medina, Scott H.; Tong, Dedi; Huang, Yong; Grahammer, Johanna; Furtmüller, Georg J.; Oh, Byoung Chol; Nagy-Smith, Katelyn J.; Walczak, Piotr; Brandacher, Gerald; Schneider, Joel P.

    2016-01-01

    Many surgeries are complicated by the need to anastomose, or reconnect, micrometre-scale vessels. Although suturing remains the gold standard for anastomosing vessels, it is difficult to place sutures correctly through collapsed lumen, making the procedure prone to failure. Here, we report a multiphase transitioning peptide hydrogel that can be injected into the lumen of vessels to facilitate suturing. The peptide, which contains a photocaged glutamic acid, forms a solid-like gel in a syringe and can be shear-thin delivered to the lumen of collapsed vessels (where it distends the vessel) and the space between two vessels (where it is used to approximate the vessel ends). Suturing is performed directly through the gel. Light is used to initiate the final gel-sol phase transition that disrupts the hydrogel network, allowing the gel to be removed and blood flow to resume. This gel adds a new tool to the armamentarium for micro- and supermicrosurgical procedures.

  15. A multiphase transitioning peptide hydrogel for suturing ultrasmall vessels.

    PubMed

    Smith, Daniel J; Brat, Gabriel A; Medina, Scott H; Tong, Dedi; Huang, Yong; Grahammer, Johanna; Furtmüller, Georg J; Oh, Byoung Chol; Nagy-Smith, Katelyn J; Walczak, Piotr; Brandacher, Gerald; Schneider, Joel P

    2016-01-01

    Many surgeries are complicated by the need to anastomose, or reconnect, micrometre-scale vessels. Although suturing remains the gold standard for anastomosing vessels, it is difficult to place sutures correctly through collapsed lumen, making the procedure prone to failure. Here, we report a multiphase transitioning peptide hydrogel that can be injected into the lumen of vessels to facilitate suturing. The peptide, which contains a photocaged glutamic acid, forms a solid-like gel in a syringe and can be shear-thin delivered to the lumen of collapsed vessels (where it distends the vessel) and the space between two vessels (where it is used to approximate the vessel ends). Suturing is performed directly through the gel. Light is used to initiate the final gel-sol phase transition that disrupts the hydrogel network, allowing the gel to be removed and blood flow to resume. This gel adds a new tool to the armamentarium for micro- and supermicrosurgical procedures. PMID:26524396

  16. Brief communication: Ectocranial suture closure in Pongo: pattern and phylogeny.

    PubMed

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2010-11-01

    Ectocranial suture fusion patterns have been shown to contain biological and phylogenetic information. Previously the patterns of Homo, Pan, and Gorilla have been described. These data reflect the phylogenetic relationships among these species. In this study, we applied similar methodology to Pongo to determine the suture synostosis progression of this genus, and to allow comparison to previously reported data on other large-bodied hominoids. We hypothesized these data would strengthen the argument that suture synostosis patterns reflect the phylogeny of primate taxa. Results indicate that the synostosis of vault sutures in Pongo is similar to that reported for Gorilla (excluding Pan and Homo). However, the lateral-anterior pattern of fusion, in which there is a strong superior to inferior pattern, for Pongo is unique among these species, reflecting its phylogenetic distinctness among great ape taxa.

  17. [Skull fracture or accessory suture in a child?].

    PubMed

    Burkhard, Katrin; Lange, Lena M; Plenzig, Stefanie; Verhoff, Marcel A; Kölzer, Sarah C

    2016-01-01

    Differentiation between accessory sutures and fractures in the skull of an infant can be difficult. Apart from the regular sutures there is a multitude of variations that may be mistaken for a fracture line. Such variations include for instance the intraparietal suture between the two ossification centers of the parietal bone or the mendosal suture between the supraoccipital and interparietal bone of the occipital squama. The presented case refers to an approximately 20-month-old female child. During autopsy, a discontinuity in the right paramedian posterior cranial fossa parallel to the internal occipital crest with connection to the foramen magnum was observed. The macroscopic findings suggested a fracture line because of its course. However, neither a hemorrhage in the soft tissue nor callus formation was discernible. The discontinuity was preserved with the adjacent parts of the occipital bone for further histological examination. In the report of a cranial CT, which was carried out five days before the child's death, an accessory suture paramedially in the right posterior cranial fossa was described. When the clinical CT records were re-evaluated, a similar discontinuity at the corresponding position on the other side was detected, though of noticeably shorter length. Additionally, the preserved occipital bone fragment including the discontinuity was histologically processed. In the radiological literature, precise (radiological) criteria for differential diagnosis are indicated. A zigzag pattern with sclerotic borders and a bilateral and fairly symmetric occurrence indicate a suture, whereas a sharp lucency with non-sclerotic edges and a unilateral occurrence indicate a fracture. Taking all the findings into account, the depicted discontinuity was regarded as an accessory suture. This case demonstrates that differentiation between a fracture and an accessory suture may be difficult in the autopsy of a child and underlines the importance of a postmortem CT

  18. Experimental evaluation of horse hair as a nonabsorbable monofilament suture

    PubMed Central

    Yedke, Swati R.; Raut, Subhash Y.; Jangde, C. R.

    2013-01-01

    Background: Success of surgery depends on wound closure and healing. Ancients had coated many suture materials from plant and animal origin. As the quest for natural nonabsorbable, monofilament surgical suture continues, horsehair has been taken for study, which is mentioned in ancient literature. Objectives: Aim of the study was to evaluate detail mechanical and biophysical properties of horsehair. Materials and Methods: Physical properties, that are diameter, straight pull and knot pull tensile strength, bioburden, sterility tests were performed. Visual and histological wound healing parameters were studied in experimental Wistar rat incision wound model. Two experimental wounds about 5 cm long were created on each side of dorsal midline. Each animal received two sutures-Horsehair 4-0 and Ethilon 4-0. The sutured areas were grossly examined on 3rd and 7th days for visual observations like congestion, edema, infection, wound disruption, and impression of suture material on healed wound and then subjected for histological study. Results: Revealed that horsehair has got diameter of 0.19 mm which complies with the 4-0 size USP standard. Straight pull tensile strength was found 0.5851 ± 0.122 kg and knot pull tensile strength was 0.3998 ± 0.078 kg, which complies with the standards of United State Pharmacopia for class II nonabsorbable suture materials. In vivo study revealed that there was no evidence of edema, congestion, and discharge in both the groups. Wounds healed with minimum impressions of suture material with minimum scar mark. Mean histological scoring shows very mild tissue reaction. Conclusion: Horsehair has got properties of standard suture material except low tensile strength and hence can be used in reconstructive, plastic surgeries, and ophthalmic surgeries. PMID:24459386

  19. External Dacryocystorhinostomy with and Without Suturing the Posterior Mucosal Flaps

    PubMed Central

    Kaçaniku, Gazmend; Begolli, Ilir

    2014-01-01

    ABSTRACT Purpose: To evaluate the outcome of the external dacryocystorhinostomy with and without suturing the posterior mucosal flaps. Methods: This study included 106 patients with lacrimal drainage system disorders who underwent the external dacryocystorhinostomy. Fifty four patients (Group A) underwent external dacryocystorhinostomy with suturing anterior and posterior flaps of the lacrimal sac and nasal mucosa, and the results obtained were compared with those of another series of 52 patients (Group B) where dacryocystorhinostomy was performed with suturing only the anterior flaps, whereas posterior mucosal flaps were excised. Results: The success rate was evaluated by lacrimal patency to irrigation and relief of epiphora. Patency achieved in groups A and B was 94.4% and 96.2%, respectively. There was no statistically significant difference in success rate between the groups. Conclusion: Our study suggests that external dacryocystorhinostomy with suturing anterior and posterior flaps have no advantage over dacryocystorhinostomy with suturing only anterior flaps. Anastomosis by suturing only anterior flaps and excision of the posterior flaps is easier to perform and may improve the success rate of external dacryocystorhinostomy. PMID:24783915

  20. Suture Forces in Undersized Mitral Annuloplasty: Novel Device and Measurements

    PubMed Central

    Siefert, Andrew; Pierce, Eric; Lee, Madonna; Jensen, Morten; Aoki, Chikashi; Takebayashi, Satoshi; Gorman, Robert; Gorman, Joseph; Yoganathan, Ajit

    2014-01-01

    Purpose: Demonstrate the first use of a novel technology for quantifying suture forces on annuloplasty rings to better understand the mechanisms of ring dehiscence. Description: Force transducers were developed, attached to a size 24 Physio™ ring, and implanted in the mitral annulus of an ovine animal. Ring suture forces were measured after implantation and for cardiac cycles reaching peak left ventricular pressures (LVP) of 100, 125, and 150 mmHg. Evaluation: After implanting the undersized ring to the flaccid annulus, the mean suture force was 2.0±0.6 N. During cyclic contraction, anterior ring suture forces were greater than posterior ring suture forces at peak LVPs of 100 mmHg (4.9±2.0 N vs. 2.1±1.1 N), 125 mmHg (5.4±2.3 N vs. 2.3±1.2 N), and 150 mmHg (5.7±2.4 N vs. 2.4±1.1 N). The largest force was 7.4 N at 150 mmHg. Conclusions: Preliminary results demonstrate trends in annuloplasty suture forces and their variation with location and LVP. Future studies will significantly contribute to clinical knowledge by elucidating the mechanisms of ring dehiscence while improving annuloplasty ring design and surgical repair techniques. PMID:24996707

  1. Electron spin resonance study of. gamma. -irradiated nylon 6

    SciTech Connect

    Takigami, S.; Matsumoto, I.; Nakamura, Y.

    1981-12-01

    The free radicals trapped in oriented nylon 6 filaments after ..gamma..-irradiation under vacuum at room temperature were studied by ESR spectroscopy. The ESR spectrum measured after irradiation gradually changed to a broad singlet spectrum with decrease in the intensity. The ESR spectrum consisted of radicals with different orientation effects with respect to the outer magnetic field, and saturation effects in reference to microwave power. The simulation of the ESR spectrum from a Gaussian function gave a better fit to the observed spectrum than the calculation from a Lorentzian function. From the resolution of the spectrum from a Gaussian function, the observed spectrum is generated from three kinds of radicals. The relative radical concentration for the first, second, and third radical is about 75%, 6%, and 19% of the total radical concentration, respectively. With regard to the stability of the radicals, the third radical shows a comparatively long lifetime. The first and second radicals show almost identical lifetime, and their concentrations reduce to about 40% of the initial value during the 2 days at room temperature.

  2. Highly Stretchable Non-volatile Nylon Thread Memory

    NASA Astrophysics Data System (ADS)

    Kang, Ting-Kuo

    2016-04-01

    Integration of electronic elements into textiles, to afford e-textiles, can provide an ideal platform for the development of lightweight, thin, flexible, and stretchable e-textiles. This approach will enable us to meet the demands of the rapidly growing market of wearable-electronics on arbitrary non-conventional substrates. However the actual integration of the e-textiles that undergo mechanical deformations during both assembly and daily wear or satisfy the requirements of the low-end applications, remains a challenge. Resistive memory elements can also be fabricated onto a nylon thread (NT) for e-textile applications. In this study, a simple dip-and-dry process using graphene-PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) ink is proposed for the fabrication of a highly stretchable non-volatile NT memory. The NT memory appears to have typical write-once-read-many-times characteristics. The results show that an ON/OFF ratio of approximately 103 is maintained for a retention time of 106 s. Furthermore, a highly stretchable strain and a long-term digital-storage capability of the ON-OFF-ON states are demonstrated in the NT memory. The actual integration of the knitted NT memories into textiles will enable new design possibilities for low-cost and large-area e-textile memory applications.

  3. Highly Stretchable Non-volatile Nylon Thread Memory

    PubMed Central

    Kang, Ting-Kuo

    2016-01-01

    Integration of electronic elements into textiles, to afford e-textiles, can provide an ideal platform for the development of lightweight, thin, flexible, and stretchable e-textiles. This approach will enable us to meet the demands of the rapidly growing market of wearable-electronics on arbitrary non-conventional substrates. However the actual integration of the e-textiles that undergo mechanical deformations during both assembly and daily wear or satisfy the requirements of the low-end applications, remains a challenge. Resistive memory elements can also be fabricated onto a nylon thread (NT) for e-textile applications. In this study, a simple dip-and-dry process using graphene-PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) ink is proposed for the fabrication of a highly stretchable non-volatile NT memory. The NT memory appears to have typical write-once-read-many-times characteristics. The results show that an ON/OFF ratio of approximately 103 is maintained for a retention time of 106 s. Furthermore, a highly stretchable strain and a long-term digital-storage capability of the ON-OFF-ON states are demonstrated in the NT memory. The actual integration of the knitted NT memories into textiles will enable new design possibilities for low-cost and large-area e-textile memory applications. PMID:27072786

  4. Summary of aging effects on 25-year old nylon parachutes

    SciTech Connect

    Tadios, E.L.

    1989-01-01

    The results of structural evaluations on several parachute systems were examined to determine if any trends could be found that would indicate significant aging in the materials. All of the parachutes were more than 20 years old. Five 64 ft diameter parachutes were evaluated along with three 16.5 ft diameter ribbon parachutes and one 4 ft diameter guide surface parachute. Another group included six 48 ft diameter ribbon parachutes, two 4 ft diameter guide surface parachutes, and two 16.5 ft diameter extraction ribbon parachutes. The parachute systems used in the study were all fabricated from nylon materials. Data were obtained for several material properties such as tensile strength, air permeability and melting point. Military specifications were used as zero-time data base due to lack of raw material data. Generally speaking, after 25 years the material properties of the 64 ft parachutes were within specifications. The same generalization cannot be made for the 48 ft parachutes which were about 23 years old. The explanation for their differences may lie in their respective histories. 10 refs., 2 figs., 5 tabs.

  5. Effect of nylon bag and protozoa on in vitro corn starch disappearance.

    PubMed

    van Zwieten, J T; van Vuuren, A M; Dijkstra, J

    2008-03-01

    An in vitro experiment was carried out to study whether the presence of protozoa in nylon bags can explain the underestimation of the in situ degradation of slowly degradable starch. Corn of a high (flint) and a low (dent) vitreousness variety was ground over a 3-mm screen, weighed in nylon bags with a pore size of 37 microm, and washed in cold water. Samples of washed cornstarch were incubated in 40-mL tubes with faunated and defaunated ruminal fluid. An additional amount of washed corn, in nylon bags, was inserted in each incubation tube. Incubations were carried out for 0, 2, 4, 6, 12, and 24 h, and starch residue in tube and nylon bag was determined. In general, starch disappearance from the nylon bag was less than from the tube, and was less with faunated than defaunated rumen fluid, but corn variety did not affect starch disappearance. When no protozoa were present, the disappearance of starch from the bags was higher after 6 and 12 h incubation compared with presence of protozoa. However, in the tubes, there was no difference in starch disappearance due to presence or absence of protozoa. Estimated lag time was higher in presence (4.6 h) then absence (3.6 h) of protozoa. It was concluded that the effect of presence or absence of protozoa on starch disappearance differs within or outside nylon bags. The reduced disappearance rate of starch inside the nylon bags in the presence of protozoa helps to explain the underestimation of starch degradation based on the in sacco procedure when compared with in vivo data upon incubation of slowly degradable starch sources. PMID:18292269

  6. Disposable circumcision suture device: clinical effect and patient satisfaction.

    PubMed

    Lv, Bo-Dong; Zhang, Shi-Geng; Zhu, Xuan-Wen; Zhang, Jie; Chen, Gang; Chen, Min-Fu; Shen, Hong-Liang; Pei, Zai-Jun; Chen, Zhao-Dian

    2014-01-01

    In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture device (DCSD). A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group). Patients in the DCSD group were anesthetized with compound 5% lidocaine cream, the others with a 2% lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were significantly lower in the Shang ring and suture device groups compared to the conventional group (P < 0.001). Intra-operative pain was less in the suture device group compared with the other two groups (P < 0.001); whereas post-operative pain was higher in the conventional group compared to the other two groups (P < 0.001). Patients in the suture device (80.57%) and Shang ring (73.57%) groups were more satisfied with penile appearances compared with the conventional circumcision group (20.06%, P < 0.05). Patients in suture device group also healed markedly faster than the conventional group (P < 0.01). The overall satisfaction rate was better in the suture device group (78.66%) compared with the conventional (47.13%) and Shang ring (50.00%) groups (P < 0.05). The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra-operative and post-operative pain and improved patient satisfaction with the cosmetic appearances. PMID:24759586

  7. Mechanical Properties of Laser-Sintered-Nylon Diamond Lattices

    NASA Astrophysics Data System (ADS)

    Neff, Clayton

    Additive manufacturing offers a manufacturing technique to produce complex geometry prototypes at a rapid pace and low cost. These advantages advocate additive manufacturing for the design and production of cellular structures. Cellular structures are interesting because they contain a large amount of porosity (void space of air) to manifest a lightweight structure. Designs of cellular structures generate a periodic pattern; often of complex geometry, called a lattice. There has been a significant amount of research to maximize specific stiffness of lattice structures but little to evaluate low-stiffness lattices. Low-stiffness structures benefit energy absorbance through bending of the lattice. This research seeks to assess diamond lattices as low stiffness, bending structures. The research involves PA2200 (Nylon 12) laser sintered diamond lattices with experimental compression testing and direct FEA model comparison. A correction factor is applied for a design offset of laser sintered lattices. Once applied, the experimental and FEA data agree in validating the diamond lattice as a bending-dominated structure. Diamond lattices show a 4th order relationship between stiffness and parameters of thickness and unit cell length. For density, stiffness maintains a 2nd order relationship, as predicted by bending dominated structures. The resulting stiffness can be tuned over a stiffness range of four orders of magnitude. Further research shows the results for modifying the diamond lattice and scaling stiffness and density using other materials (like metals) to expand the range of stiffness and compare diamond lattices on material property charts. Lastly, the effective Poisson's ratio varies from 0.5 to 0.4 depending on the (t/L) ratio.

  8. Nylon and teflon scribe effect on NBR to Chemlok 233 and NBR to NBR bond interfaces

    NASA Technical Reports Server (NTRS)

    Jensen, S. K.

    1990-01-01

    A study was requested by Manufacturing Engineering to determine what effects marking with nylon (6/6) and Teflon scribes may have on subsequent bonding. Witness panel bond specimens were fabricated by the development lab to test both acrylonitrile butadiene rubber (NBR) to Chemlok and NBR to NBR after controlled exposure. The nylon rod used as a scribe tool demonstrates virtually no bond deterioration when used to scribe lines on either the Chemlok to NBR surfaces or the NBR to NBR interface. Lab test results indicate that the nylon rod-exposed samples produce tensile and peel values very similar to the control samples and the Teflon exposed samples produce tensile and peel values much lower than the control samples. Visual observation of the failure surfaces of the tested samples shows that Teflon scribing produces an obvious contamination to the surface and the nylon produces no effect. Photographs of test samples are provided. It is concluded that Teflon stock used as a scribe tool on a Chemlok 233 to NBR surface or an NBR to NBR surface has a detrimental effect on the bond integrity on either of these bond interfaces. Therefore, it is recommended that the nylon rod continue to be used where a scribe line is required in the redesigned solid rocket motor segment insulation layup operations. The use of Teflon scribes should not be considered.

  9. Nylon 6-Gold Nanoparticle Composite Fibers for Colorimetric Detection of Urinary 1-Hydroxypyrene

    NASA Astrophysics Data System (ADS)

    Ifegwu, O. Clinton; Anyakora, C.; Torto, N.

    2015-05-01

    A one-step in situ synthesis of nylon 6 nanofibers filled with gold nanoparticles for the colorimetric probe of 1-hydroxypyrene, a biomarker associated with the largest class of cancer-causing chemical compounds polycyclic aromatic hydrocarbons (PAHs) is proposed in this study. The gold nanoparticles (AuNPs) were successfully embedded on the surface of the nylon 6 fibers where the gold particles were chemisorbed onto the amide groups in the nylon 6 backbones. By electrospinning the nylon 6/gold nanocomposite, the gold nanoparticles were uniformly dispersed on the polymer fibers to give a photostable reddish white fiber which turned purple/blue when brought in contact with a standard solution of the biomarker. The TEM revealed the formation of spherical AuNPs with an average diameter of 8 nm well arrayed within the nanofibers, but no significant change in the morphology of the nanofibers was observed. The thermal properties of the composite fibers were greatly improved compared to the electrospun nylon 6 fiber. The developed method described herein is simple, effective, requires no post-treatments, and is highly sensitive (100 ng/ml) hence the nanocomposite fibers can be employed as a test strip for the colorimetric detection of 1-hydroxypyrene in human urine or other diagnostic probe biosensors.

  10. EELS Analysis of Nylon 6 Nanofibers Reinforced with Nitroxide-Functionalized Graphene Oxide

    PubMed Central

    Leyva-Porras, César; Ornelas-Gutiérrez, C.; Miki-Yoshida, M.; Avila-Vega, Yazmín I.; Macossay, Javier; Bonilla-Cruz, José

    2014-01-01

    A detailed analysis by transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) of nitroxide-functionalized graphene oxide layers (GOFT) dispersed in Nylon 6 nanofibers is reported herein. The functionalization and exfoliation process of graphite oxide to GOFT was confirmed by TEM using electron diffraction patterns (EDP), wherein 1 to 4 graphene layers of GOFT were observed. The distribution and alignment of GOFT layers within a sample of Nylon 6 nanofiber reveals that GOFT platelets are mainly within the fiber, but some were partially protruding from it. Furthermore, Nylon 6 nanofibers exhibit an average diameter of 225 nm with several microns in length. GOFT platelets embedded into the fiber, the pristine fiber, and amorphous carbon were analyzed by EELS where each spectra [corresponding to the carbon edge (C-K)] exhibited changes in the fine structure, allowing a clear distinction between: i) GOFT single-layers, ii) Nylon-6 nanofibers, and iii) the carbon substrate. EELS analysis is presented here for the first time as a powerful tool to identify functionalized graphene single-layers (< 4 layers of GOFT) into a Nylon 6 nanofiber composite. PMID:24634536

  11. Experimental and Computational Analysis of Cellular Interactions with Nylon-3-Bearing Substrates

    PubMed Central

    Liu, Runhui; Vang, Kang Z.; Kreeger, Pamela K.; Gellman, Samuel H.; Masters, Kristyn S.

    2012-01-01

    The ability to design biomaterials that interact with biological environments in a predictable manner necessitates an improved understanding of how surface chemistry influences events such as protein adsorption and cell adhesion. In this work, we examined mechanisms governing the interactions between 3T3 fibroblasts and nylon-3 polymers, which have a protein-like polyamide backbone and are highly amenable to tuning of chemical and physical properties. Protein adsorption and cell adhesion to a library of nylon-3 polymers were characterized and analyzed by partial least squares regression. This analysis revealed that specific chemical features of the nylon-3 polymers correlated with the extent of protein adsorption, which, in turn, correlated with cell adhesion in a serum-containing environment. In contrast, in a serum-free environment, cell adhesion could be predicted solely from chemical properties. Enzymatic treatments of 3T3 cells prior to plating indicated that proteins bound to the cell surface mediated cell-nylon-3 polymer interactions under serum-free conditions, with additional analysis suggesting that cell-associated fibronectin played a dominant role in adhesion in the absence of serum. The mechanistic insight gained from these studies can be used to inform the design of new polymer structures in addition to providing a basis for continued development of nylon-3 copolymers for tissue engineering applications. PMID:22623026

  12. EELS Analysis of Nylon 6 Nanofibers Reinforced with Nitroxide-Functionalized Graphene Oxide.

    PubMed

    Leyva-Porras, César; Ornelas-Gutiérrez, C; Miki-Yoshida, M; Avila-Vega, Yazmín I; Macossay, Javier; Bonilla-Cruz, José

    2014-01-01

    A detailed analysis by transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) of nitroxide-functionalized graphene oxide layers (GOFT) dispersed in Nylon 6 nanofibers is reported herein. The functionalization and exfoliation process of graphite oxide to GOFT was confirmed by TEM using electron diffraction patterns (EDP), wherein 1 to 4 graphene layers of GOFT were observed. The distribution and alignment of GOFT layers within a sample of Nylon 6 nanofiber reveals that GOFT platelets are mainly within the fiber, but some were partially protruding from it. Furthermore, Nylon 6 nanofibers exhibit an average diameter of 225 nm with several microns in length. GOFT platelets embedded into the fiber, the pristine fiber, and amorphous carbon were analyzed by EELS where each spectra [corresponding to the carbon edge (C-K)] exhibited changes in the fine structure, allowing a clear distinction between: i) GOFT single-layers, ii) Nylon-6 nanofibers, and iii) the carbon substrate. EELS analysis is presented here for the first time as a powerful tool to identify functionalized graphene single-layers (< 4 layers of GOFT) into a Nylon 6 nanofiber composite. PMID:24634536

  13. Comparison of computed tomography dose index in polymethyl methacrylate and nylon dosimetry phantoms.

    PubMed

    Sookpeng, Supawitoo; Cheebsumon, Patsuree; Pengpan, Thanyawee; Martin, Colin

    2016-01-01

    The use of computed tomography (CT) scanning has been growing steadily. Therefore, CT dose measurement is becoming increasingly important for patient protection and optimization. A phantom is an important tool for dose measurement. This paper focuses on the evaluation of a CT dosimetry phantom made from nylon, instead of the standard polymethyl methacrylate (PMMA), which is not readily available or is too expensive in some countries. Comparison between phantoms made from the two materials is made in terms of measurements of the CT dose indices (CTDI). These were measured for four different beam widths and kVp settings at the center and periphery in head and body phantoms made from both materials and weighted CTDIs (CTDIw) were calculated. CT numbers along the z-axis of the phantom were also measured at the center and four peripheral positions of each scanned slice to check phantom homogeneity. Results showed that values for the CTDIw measured in the nylon phantoms were slightly higher than those from the PMMA while CT numbers for nylon were lower than those of PMMA. This is because the mass attenuation coefficient of the nylon is higher. Nylon could be used as a substitute material for CT dosimetry phantom to enable measurements and adjustment factors are given which could be used to estimate PMMA values for making comparisons with displayed values. PMID:27051170

  14. EELS Analysis of Nylon 6 Nanofibers Reinforced with Nitroxide-Functionalized Graphene Oxide.

    PubMed

    Leyva-Porras, César; Ornelas-Gutiérrez, C; Miki-Yoshida, M; Avila-Vega, Yazmín I; Macossay, Javier; Bonilla-Cruz, José

    2014-01-01

    A detailed analysis by transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) of nitroxide-functionalized graphene oxide layers (GOFT) dispersed in Nylon 6 nanofibers is reported herein. The functionalization and exfoliation process of graphite oxide to GOFT was confirmed by TEM using electron diffraction patterns (EDP), wherein 1 to 4 graphene layers of GOFT were observed. The distribution and alignment of GOFT layers within a sample of Nylon 6 nanofiber reveals that GOFT platelets are mainly within the fiber, but some were partially protruding from it. Furthermore, Nylon 6 nanofibers exhibit an average diameter of 225 nm with several microns in length. GOFT platelets embedded into the fiber, the pristine fiber, and amorphous carbon were analyzed by EELS where each spectra [corresponding to the carbon edge (C-K)] exhibited changes in the fine structure, allowing a clear distinction between: i) GOFT single-layers, ii) Nylon-6 nanofibers, and iii) the carbon substrate. EELS analysis is presented here for the first time as a powerful tool to identify functionalized graphene single-layers (< 4 layers of GOFT) into a Nylon 6 nanofiber composite.

  15. Crystalline Morphology and Polymorphic Phase Transitions in Electrospun Nylon-6 Nanofibers

    SciTech Connect

    Liu,Y.; Cui, L.; Guan, F.; Gao, Y.; Hedin, N.; Zhu, L.; Fong, H.

    2007-01-01

    Uniform nylon-6 nanofibers with diameters around 200 nm were prepared by electrospinning. Polymorphic phase transitions and crystal orientation of nylon-6 in unconfined (i.e., as-electrospun) and a high T{sub g} (340 C) polyimide confined nanofibers were studied. Similar to melt-spun nylon-6 fibers, electrospun nylon-6 nanofibers also exhibited predominant, metastable {gamma}-crystalline form, and the {gamma}-crystal (chain) axes preferentially oriented parallel to the fiber axis. Upon annealing above 150 C, {gamma}-form crystals gradually melted and recrystallized into thermodynamically stable {alpha}-form crystals, which ultimately melted at 220 C. Release of surface tension accompanied this melt-recrystallization process, as revealed by differential scanning calorimetry. For confined nanofibers, both the melt-recrystallization and surface tension release processes were substantially depressed; {gamma}-form crystals did not melt and recrystallize into {alpha}-form crystals until 210 C, only 10 C below the T{sub m} at 220 C. After complete melting of nanoconfined crystals at 240 C and recrystallization at 100 C, only {alpha}-form crystals oriented perpendicular to the nanofiber axis were obtained. In the polyimide-confined nanofibers, the Brill transition (from the monoclinic {alpha}-form to a high-temperature monoclinic form) was observed at 180-190 C, which was at least 20 C higher than that in unconfined nylon-6 at {approx}160 C. This, again, was attributed to the confinement effect.

  16. The effect of saliva and oral intake on the tensile properties of sutures: an experimental study.

    PubMed

    Ferguson, Robert E H; Schuler, Kevin; Thornton, Brian P; Vasconez, Henry C; Rinker, Brian

    2007-03-01

    The plastic surgeon often operates in the oral cavity. Little or no information exists regarding the effect of saliva and oral intake upon the tensile properties of suture. Polyglactin 910 (Vicryl) and chromic gut were studied. Five sutures of each type were subjected to saline, saliva, milk, or soy milk over different durations of exposure. Suture breaking strength was tested. A 4-way interaction between suture type, size, liquid, and time was significant (P = 0.0046). Sutures soaked in saliva were significantly weaker. No significant difference was observed between sutures soaked in milk or soy. Saliva appears to enhance degradation rates in both sutures. Suture selection in the oral cavity should be predicated upon the demands of the repair and surgeon's preference. Postoperative feeding instructions should limit tension across mucosal repairs, but the selection of formula should be based upon nutritional requirements and preferences of the child rather than concern over suture degradation.

  17. Recognizing surgeon's actions during suture operations from video sequences

    NASA Astrophysics Data System (ADS)

    Li, Ye; Ohya, Jun; Chiba, Toshio; Xu, Rong; Yamashita, Hiromasa

    2014-03-01

    Because of the shortage of nurses in the world, the realization of a robotic nurse that can support surgeries autonomously is very important. More specifically, the robotic nurse should be able to autonomously recognize different situations of surgeries so that the robotic nurse can pass necessary surgical tools to the medical doctors in a timely manner. This paper proposes and explores methods that can classify suture and tying actions during suture operations from the video sequence that observes the surgery scene that includes the surgeon's hands. First, the proposed method uses skin pixel detection and foreground extraction to detect the hand area. Then, interest points are randomly chosen from the hand area so that their 3D SIFT descriptors are computed. A word vocabulary is built by applying hierarchical K-means to these descriptors, and the words' frequency histogram, which corresponds to the feature space, is computed. Finally, to classify the actions, either SVM (Support Vector Machine), Nearest Neighbor rule (NN) for the feature space or a method that combines "sliding window" with NN is performed. We collect 53 suture videos and 53 tying videos to build the training set and to test the proposed method experimentally. It turns out that the NN gives higher than 90% accuracies, which are better recognition than SVM. Negative actions, which are different from either suture or tying action, are recognized with quite good accuracies, while "Sliding window" did not show significant improvements for suture and tying and cannot recognize negative actions.

  18. Selective laser vaporization of polypropylene sutures and mesh

    NASA Astrophysics Data System (ADS)

    Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.

    2012-02-01

    Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.

  19. Quantitative evaluation of midpalatal suture maturation via fractal analysis

    PubMed Central

    Kwak, Kyoung Ho; Kim, Yong-Il; Kim, Yong-Deok

    2016-01-01

    Objective The purpose of this study was to determine whether the results of fractal analysis can be used as criteria for midpalatal suture maturation evaluation. Methods The study included 131 subjects aged over 18 years of age (range 18.1–53.4 years) who underwent cone-beam computed tomography. Skeletonized images of the midpalatal suture were obtained via image processing software and used to calculate fractal dimensions. Correlations between maturation stage and fractal dimensions were calculated using Spearman's correlation coefficient. Optimal fractal dimension cut-off values were determined using a receiver operating characteristic curve. Results The distribution of maturation stages of the midpalatal suture according to the cervical vertebrae maturation index was highly variable, and there was a strong negative correlation between maturation stage and fractal dimension (−0.623, p < 0.001). Fractal dimension was a statistically significant indicator of dichotomous results with regard to maturation stage (area under curve = 0.794, p < 0.001). A test in which fractal dimension was used to predict the resulting variable that splits maturation stages into ABC and D or E yielded an optimal fractal dimension cut-off value of 1.0235. Conclusions There was a strong negative correlation between fractal dimension and midpalatal suture maturation. Fractal analysis is an objective quantitative method, and therefore we suggest that it may be useful for the evaluation of midpalatal suture maturation. PMID:27668195

  20. Quantitative evaluation of midpalatal suture maturation via fractal analysis

    PubMed Central

    Kwak, Kyoung Ho; Kim, Yong-Il; Kim, Yong-Deok

    2016-01-01

    Objective The purpose of this study was to determine whether the results of fractal analysis can be used as criteria for midpalatal suture maturation evaluation. Methods The study included 131 subjects aged over 18 years of age (range 18.1–53.4 years) who underwent cone-beam computed tomography. Skeletonized images of the midpalatal suture were obtained via image processing software and used to calculate fractal dimensions. Correlations between maturation stage and fractal dimensions were calculated using Spearman's correlation coefficient. Optimal fractal dimension cut-off values were determined using a receiver operating characteristic curve. Results The distribution of maturation stages of the midpalatal suture according to the cervical vertebrae maturation index was highly variable, and there was a strong negative correlation between maturation stage and fractal dimension (−0.623, p < 0.001). Fractal dimension was a statistically significant indicator of dichotomous results with regard to maturation stage (area under curve = 0.794, p < 0.001). A test in which fractal dimension was used to predict the resulting variable that splits maturation stages into ABC and D or E yielded an optimal fractal dimension cut-off value of 1.0235. Conclusions There was a strong negative correlation between fractal dimension and midpalatal suture maturation. Fractal analysis is an objective quantitative method, and therefore we suggest that it may be useful for the evaluation of midpalatal suture maturation.

  1. Material properties of common suture materials in orthopaedic surgery.

    PubMed

    Najibi, S; Banglmeier, R; Matta, Jm; Tannast, M

    2010-01-01

    Suture materials in orthopaedic surgery are used for closure of wounds, repair of fascia, muscles, tendons, ligaments, joint capsules, and cerclage or tension band of certain fractures. The purpose of this study was to compare the biomechanical properties of eleven commonly used sutures in orthopaedic surgery. Three types of braided non-absorbable and one type of braided absorbable suture material with different calibers (n=77) underwent biomechanical testing for maximum load to failure, strain, and stiffness. All samples were tied by one surgeon with a single SMC (Seoul Medical Center) knot and three square knots. The maximum load to failure and strain were highest for #5 FiberWire and lowest for #0 Ethibond Excel (p<0.001). The stiffness was highest for #5 FiberWire and lowest for #2-0 Vicryl (p<0.001). In all samples, the failure of the suture material occurred at the knot There was no slippage of the knot in any of the samples tested. This data will assist the orthopaedic surgeon in selection and application of appropriate suture materials and calibers to specific tasks. PMID:21045977

  2. MATERIAL PROPERTIES OF COMMON SUTURE MATERIALS IN ORTHOPAEDIC SURGERY

    PubMed Central

    Najibi, S; Banglmeier, R; Matta, JM; Tannast, M

    2010-01-01

    Suture materials in orthopaedic surgery are used for closure of wounds, repair of fascia, muscles, tendons, ligaments, joint capsules, and cerclage or tension band of certain fractures. The purpose of this study was to compare the biomechanical properties of eleven commonly used sutures in orthopaedic surgery. Three types of braided non-absorbable and one type of braided absorbable suture material with different calibers (n=77) underwent biomechanical testing for maximum load to failure, strain, and stiffness. All samples were tied by one surgeon with a single SMC (Seoul Medical Center) knot and three square knots. The maximum load to failure and strain were highest for #5 FiberWire and lowest for #0 Ethibond Excel (p<0.001). The stiffness was highest for #5 FiberWire and lowest for #2-0 Vicryl (p<0.001). In all samples, the failure of the suture material occurred at the knot There was no slippage of the knot in any of the samples tested. This data will assist the orthopaedic surgeon in selection and application of appropriate suture materials and calibers to specific tasks. PMID:21045977

  3. Modeling and flow analysis of pure nylon polymer for injection molding process

    NASA Astrophysics Data System (ADS)

    Nuruzzaman, D. M.; Kusaseh, N.; Basri, S.; Oumer, A. N.; Hamedon, Z.

    2016-02-01

    In the production of complex plastic parts, injection molding is one of the most popular industrial processes. This paper addresses the modeling and analysis of the flow process of the nylon (polyamide) polymer for injection molding process. To determine the best molding conditions, a series of simulations are carried out using Autodesk Moldflow Insight software and the processing parameters are adjusted. This mold filling commercial software simulates the cavity filling pattern along with temperature and pressure distributions in the mold cavity. In the modeling, during the plastics flow inside the mold cavity, different flow parameters such as fill time, pressure, temperature, shear rate and warp at different locations in the cavity are analyzed. Overall, this Moldflow is able to perform a relatively sophisticated analysis of the flow process of pure nylon. Thus the prediction of the filling of a mold cavity is very important and it becomes useful before a nylon plastic part to be manufactured.

  4. Fabrication and characterization of silver- and copper-coated Nylon 6 forcespun nanofibers by thermal evaporation

    SciTech Connect

    Mihut, Dorina M. Lozano, Karen; Foltz, Heinrich

    2014-11-01

    Silver and copper nanoparticles were deposited as thin films onto substrates consisting of Nylon 6 nanofibers manufactured using forcespinning{sup ®} equipment. Different rotational speeds were used to obtain continuous nanofibers of various diameters arranged as nonwoven mats. The Nylon 6 nanofibers were collected as successive layers on frames, and a high-vacuum thermal evaporation method was used to deposit the silver and copper thin films on the nanofibers. The structures were investigated using scanning electron microscopy–scanning transmission electron microscopy, atomic force microscopy, x-ray diffraction, and electrical resistance measurements. The results indicate that evaporated silver and copper nanoparticles were successfully deposited on Nylon 6 nanofibers as thin films that adhered well to the polymer substrate while the native morphology of the nanofibers were preserved, and electrically conductive nanostructures were achieved.

  5. Recovery of hydrophobicity of nylon aged by heat and saline water

    SciTech Connect

    Tokoro, Tetsuro; Hackam, R.

    1996-12-31

    The recovery of hydrophobicity of Nylon after aging by long exposure to a stress of saline water at different temperatures is investigated. The hydrophobicity is determined by measuring the contact angle of a droplet of distilled water on Nylon. The aging of Nylon was done by immersing it for up to 336 h in saline water solutions in the range 5.0 {times} 10{sup 5} {micro}S/cm. The aging temperatures were 0 to 98 C. After aging, the specimens were kept in air at room temperature for up to 4,500 h during which the recovery of hydrophobicity and weight changes were measured. Specimens were also kept in high vacuum for 20 h to determine the changes in the contact angle and in the weight with the absence of air.

  6. Interfacial adhesion in rayon/nylon sheath/core composite fibers

    SciTech Connect

    Tao Weiying.

    1991-01-01

    The fibers with enhanced adhesion were produced using a wire coating type process. One objective was to determine an effective coupling agent and the most-appropriate application conditions for maximum interfacial adhesion in the rayon/nylon bicomponent fibers. The second objective was to characterize the interfacial adhesion between the core fiber and the rayon skin. After removal of the spin finish by water washing, the nylon core fibers were pretreated with fumaric acid (FA) as an adhesion promoter and then were coated with viscose rayon. The results indicated that the interfacial adhesion in the rayon/nylon composite fibers was significantly improved under the application conditions of 1.0% with 36 second pretreatment time, 1.5% with 18 second pretreatment, and 2% with 9 second pretreatment time. A fiber pull adhesion test method was developed to test the interfacial adhesion. This method effectively determined the adhesion between the core and the skin.

  7. Is the Kapuskasing structure the site of a cryptic suture

    NASA Technical Reports Server (NTRS)

    Burke, K.

    1983-01-01

    The demonstration that the Kapuskasing structure involves substantial thrusting of deep continental crustal rocks over shallower continental rocks calls into question an earlier suggestion (by Wilson) that the Circum-Ungaua suture zone continued through the Kapuskasing to join the Penokean fold belt (implying that the Kapuskasing marked the site of what has since come to be called a cryptic suture). Problems are discussed which arose in attempting to reconcile Wilson's idea with data from more recent studies: whether the Kapuskasing and the Thompson belt both mark sutures of about 1700 Ma age; why there is no age difference across the Kapuskasing if it does mark the site of continental collision, and why there is no offset of Superior subprovinces across the Kapuskasing.

  8. The relative efficiency of nylon and cotton gill nets for taking lake trout in Lake Superior

    USGS Publications Warehouse

    Pycha, Richard L.

    1962-01-01

    The change from cotton to nylon twine for gill nets in 1949–52 resulted in a sharp increase in the efficiency of the most important gear used for taking lake trout in Lake Superior, and, consequently, biased estimates of fishing intensity and abundance severely.From early May to the end of September 1961, short gangs (2000 or 4000 linear feet) of cotton and nylon nets were fished in parallel sets for lake trout. A total of 343,000 feet of gill netting was lifted. Nylon nets were 2.25 times as efficient as cotton nets for taking legal-sized fish and 2.8 times as efficient for undersized lake trout. The average lengths of legal, undersized, and all lake trout taken in nets of the two materials did not differ greatly. The percentage of the catch which was undersized (less than 1.25 lb, dressed weight) was 20.8 in nylon nets and 17.7 in cotton. The relative efficiency of cotton and nylon nets showed no trend during the season. The efficiency ratio determined in this study was closely similar to that obtained by earlier workers.Correction of estimates of fishing intensity and abundance for the greater efficiency of the nylon nets used since 1951 has not been attempted. The drastic decline of the lake trout fishery has forced fishermen to make changes in fishing practices in the past few years that cause new bias of an unknown extent to estimates of fishing intensity.

  9. Influence of metopic suture fusion associated with sagittal synostosis.

    PubMed

    Domeshek, Leahthan F; Das, Rajesh R; Van Aalst, John A; Mukundan, Srinivasan; Marcus, Jeffrey R

    2011-01-01

    Some patients with sagittal synostosis present with a fused metopic suture. We hypothesize that premature metopic suture fusion consistently and identifiably alters form associated with sagittal synostosis. We previously validated three-dimensional vector analysis as a tool for the study of cranial morphology and used it herein to distinguish between dysmorphologies of isolated sagittal synostosis (ISS) and combined sagittal-metopic synostosis (CSM). Preoperative computed tomographic scans for patients with ISS and CSM were compared with matched normative counterparts. Premature metopic suture fusion was defined by established radiographic criteria. Color-coded point clouds were created for each scan, with color gradient based on patient deviation from normal across the dysmorphic skull. Standard deviation data were evaluated in 7 cranial regions and compared between ISS and CSM. Mean ISS and CSM point clouds were evaluated. Using three-dimensional vector analysis, standard anthropometric data/indices were determined and compared between the 2 groups. Differences in ISS and CSM regional deviations and index measurements were not statistically significant. Mean ISS and CSM representations depicted similar overall morphology. Using accepted criteria for identification of metopic synostosis in CSM, only subtle differences appear between the 2 populations on average. Expected morphologic changes associated with metopic synostosis are present in only a small number of patients with CSM, arguing against our hypothesis, and calling into question the criteria used to identify premature metopic suture fusion. Normal metopic suture fusion occurs for a continuum of time. Our findings suggest that the normal continuum may begin earlier than the literature suggests. In the setting of sagittal synostosis, the influence of metopic suture fusion and treatment is best determined by individual morphologic analysis.

  10. Force-Induced Craniosynostosis in the Murine Sagittal Suture

    PubMed Central

    Oppenheimer, Adam J.; Rhee, Samuel T.; Goldstein, Steven A.; Buchman, Steven R.

    2010-01-01

    BACKGROUND The etiology of non-syndromic craniosynostosis remains elusive. While compressive forces have been implicated in premature suture fusion, conclusive evidence of force-induced craniosynostosis is lacking. The purpose of this study was to determine if cyclical loading of the murine calvarium could induce suture fusion. METHODS Calvarial coupons from post-natal day 21, B6CBA wild-type mice (n = 18) were harvested and cultured. A custom appliance capable of delivering controlled, cyclical, compressive loads was applied perpendicular to the sagittal suture within the coupon in vitro. Nine coupons were subjected to 0.3g of force for 30 minutes each day for a total of 14 days. A control group of nine coupons was clamped in the appliance without loading. Analysis of suture phenotype was performed using alkaline phosphatase and H&E staining techniques, as well as in situ hybridization analysis using Bone Sialoprotein (BSP). RESULTS Control group sagittal sutures—which normally remain patent in mice—showed their customary histological appearance. In contradistinction, sagittal sutures subjected to cyclic loading showed histological evidence of premature fusion (craniosynostosis). In addition, alkaline phosphatase activity and BSP expression was observed to be increased in the experimental group when compared to matched controls. CONCLUSIONS An in vitro model of forced-induced craniosynostosis has been devised. Premature fusion of the murine sagittal suture was induced with the application of controlled, cyclical, compressive loads. These results implicate abnormal forces in the development of non-syndromic craniosynostosis, which supports our global hypothesis that epigenetic phenomena have a crucial role in the pathogenesis of craniosynostosis. PMID:19952640

  11. Total laparoscopic hysterectomy via suture and ligation technique

    PubMed Central

    Kang, Hye Won; Lee, Ji Won; Kim, Ho Yeon; Kim, Bo Wook

    2016-01-01

    Objective The term 'total laparoscopic hysterectomy (TLH) with classical suture method' refers to a surgical procedure performed using only sutures and ligations with intracorporeal or extracorporeal ties, without using any laser or electronic cauterization devices during laparoscopic surgery as in total abdominal hysterectomy. However, the method is not as widely used as electric coagulation equipment for TLH because further advances in technology and surgical technique are required and operative time can take longer. In the current study, we evaluated the benefits of the classical suture method for TLH. Methods This study retrospectively reviewed patients who received TLH using the classical suture method from August 2005 to April 2014. The patients' baseline characteristics were analyzed, including age, parity, cause of operation, medical and surgical history. Surgical outcomes analyzed included the weight of the uterus, operative time, complications, changes in hemoglobin level, blood transfusion requirements, and postoperative hospital stay. Results Of 746 patients who underwent TLH with the classical suture method, mean operation time was 96.9 minutes. Mean average decline in hemoglobin was 1.6 g/dL and transfusion rate was 6.2%. Urinary tract injuries were reported in 8 patients. Urinary tract injuries comprised 6 cases of bladder injury and 3 cases of ureter injury. There were no cases of vaginal stump infection, hematoma, bowel injury or abdominal wound complication. All cases involving complications occurred before 2010. Conclusion The classical suture method for TLH presents tolerable levels of complications and blood loss. Advanced surgical skill is expected to decrease operation time and complications. PMID:26866034

  12. A reusable suture anchor for arthroscopy psychomotor skills training.

    PubMed

    Tillett, Edward D; Rogers, Rainie; Nyland, John

    2003-03-01

    For residents to adequately develop the early arthroscopy psychomotor skills required to better learn how to manage the improvisational situations they will encounter during actual patient cases, they need to experience sufficient practice repetitions within a contextually relevant environment. Unfortunately, the cost of suture anchors can be a practice repetition-limiting factor in learning arthroscopic knot-tying techniques. We describe a technique for creating inexpensive reusable suture anchors and provide an example of their application to repair the anterior glenoid labrum during an arthroscopy psychomotor skills laboratory training session.

  13. Familial idiopathic hypertrophic osteoarthropathy and cranial suture defects in children

    SciTech Connect

    Reginato, A.J.; Schiapachasse, V.; Guerrero, R.

    1982-05-01

    Three children with idiopathic hypertrophic osteoarthropathy and cranial suture defects are reported. The syndrome was recognized after birth and in the two oldest siblings, the cranial defects and subperiosteal bone formation resolved almost completely by age 4 and 6 years. The joint swelling and clubbing persisted and mild bone reabsorption of the distal phalanges became apparent at an older age. Two siblings and both parents had normal bone X-rays and no clubbing. This study confirms the association of cranial sutural defects and familial idopathic hypertrophic osteoarthropathy.

  14. Sutures for inguinal herniorrhaphy--a comparison of monofilaments with PTFE.

    PubMed Central

    Cahill, J.; Northeast, A. D.; Jarret, P. E.; Leach, R. D.

    1989-01-01

    Polybutester (Novafil, Davis & Geck) and expanded polytetrafluoroethylene PTFE (Gore-tex, W L Gore) were compared with nylon (Ethilon, Ethicon UK) for elective inguinal herniorrhaphy. PTFE had the best handling characteristics, but is expensive, and increased wound sepsis attended its use. Polybutester had significantly better handling characteristics, and is an attractive alternative to nylon for hernia repair. PMID:2705719

  15. Complexity of suture zones:Example from the Yarlung Zangbo Suture Zone , southern Tibet. (Invited)

    NASA Astrophysics Data System (ADS)

    Hebert, R.; Guilmette, C.

    2013-12-01

    Decade-long investigation of the Yarlung Zangbo Suture Zone (YZSZ), southern Tibet, has revealed it's high complexity in terms of structure, geochronology and metamorphic and igneous histories. For instance, YZSZ comprises Late Devonian to mid-Miocene rocks, metamorphic intensities vary from high-grade to very-low grade and deformation styles range from ductile to brittle. Late Devonian rocks (363.7 × 1.7 Ma) are alkalic gabbros resulting from activity of a plume active within the Paleo-Tethys basin. Two ophiolite sub-groups are recognized. Sub-group 1 is Mid- to Late Jurassic (150-177 Ma) in age and ill-defined because only few sequences have been found and studied so far. IThis sub-group is probably derived from the destruction of a marginal basin comprising intra-oceanic arc and fore-arc settings. Spontang and Zedong sequences are good examples of this sub-group. Sub-group 2 is Lower Cretaceous (120-130 Ma) and represents the destruction of a marginal basin comprising an arc-back-arc system. These ophiolites are spatially associated with ophiolitic mélanges and flysch respectively representing the reworking of the Cretaceous ophiolites and Indian continental margin and the Neo-Tethyan ocean floor although such affinities need clarification. Most ophiolitic sequences belong to sub-group 2 such as Xiugubagu, Saga, Xigaze. Amphibolite and garnet amphibolite blocks (123-130 Ma) found within the ophiolitic mélange share similar geochemical attributes with sub-group 2 ophiolites. Their protoliths were probably generated within back-arc spreading center and metamorphosed in a subduction zone at depth around 50 km. Some radiometric ages suggest events at 80 Ma and 90 old represent the entry of Indian continental margin into the intra-oceanic subduction zone and/or obduction of ophiolites. However these ages seem to be very rare throughout the whole suture zone and are therefore considered as resulting from local metamorphic events. Some alkaline igneous rocks (131

  16. Suture material in bladder surgery: a comparison of polydioxanone, polyglactin, and chromic catgut.

    PubMed

    Stewart, D W; Buffington, P J; Wacksman, J

    1990-06-01

    A comparison of polydioxanone, polyglactin, and chromic catgut suture was performed in 120 rat bladders studying propensity for infection, degree of inflammation, calculogenic potential, changes in urine pH, and suture absorption. None of the sutures predisposed to infection and there was wide variability but no correlation in urine pH. Although initially the polydioxanone incited a greater inflammatory response, by six months all three sutures were similar. The absorption of polydioxanone was slower than chromic catgut suture, but similar to the absorption of polyglactin. There was no significant difference in calculogenic potential between the suture materials tested over a six-month period. Based on this study in rats, polydioxanone suture would appear to be equal to catgut and polyglactin suture in bladder surgery.

  17. Half-bow sliding knot: modified suture technique for scleral fixation using the corneoscleral pocket.

    PubMed

    Chee, Soon-Phaik

    2011-09-01

    A modified suture technique for precise knot placement in the Hoffman corneoscleral pocket technique of scleral fixation is described. Both loops of the polypropylene suture passing from the intraocular device through the sclera and conjunctiva are retrieved from the pocket. A loop of suture is pulled through 3 suture throws made using the second suture loop, forming a half bow. Centration of the intraocular lens (IOL)-capsular bag is checked. If the suture tension is too tight, the surgeon can easily undo the knot of the half-bow knot by pulling it free and can then retie the sliding knot. When the IOL-capsular bag is centered, the suture loop is cut and the free end removed. The second suture end is retrieved from the pocket, and knot tying is completed without further adjustment to the tension. Posterior pressure on the intraocular device centers it and settles the knot within the sclera at the fixation point.

  18. A safety technique for Mitek anchor suture rupture: a useful trick.

    PubMed

    Othman, Diaa; Le Cocq, Heather; Majumder, Sanjib

    2011-09-01

    We propose that the simple method of passing an extra suture through the Mitek anchor eyelet before bony insertion provides a safety net against failure of the preloaded suture and gives extra strength to the core repair.

  19. An Update on the Use of Barbed Suture in Minimally Invasive Gynecological Surgery (MIGS).

    PubMed

    Kondrup, James Dana; Anderson, Frances R

    2016-04-01

    The use of barbed suture has enabled general and minimally invasive gynecological surgery (MIGS) surgeons to close surgical wounds more efficiently with minimal complications. This article reviews developments in barbed (knotless) sutures and related devices.

  20. [The resistance to infection of digestive sutures. Experimental study (author's transl)].

    PubMed

    Bellamy, J; Brunschvicg, O; Fékété, F; Lortat-Jacob, J L

    1977-01-01

    The authors study the effects of severe sepsis due to pathogenic gems in large quantity an healing of the suture of the ileum in the rabbit. Contamination of the suture did not lead to any breakdown of the suture whatever the germ. These experimental facts, compared with the data in the literature suggest that the peritoneal serosa ensures efficacious anti-infectious defence, permitting healing of intra-peritoneal digestive sutures in spite of the septic nature of the intestinal contents. PMID:885933

  1. Modified Margin Convergence: Over-Under Lacing Suture Technique

    PubMed Central

    Métais, Pierre; Lanzone, Roberto; Lim, Chauncey Kester; Albino, Paolo; Carbone, Stefano

    2015-01-01

    The principle of margin convergence can be applied to rotator cuff repair to enhance the security of fixation by decreasing the mechanical strain at the margins of the tear. We describe a suture technique, over-under lacing, that reproduces the same margin convergence, with equal tissue tension across the entire surface area of the cuff. A consecutive series of patients affected by massive U-shaped rotator cuff tears were treated by this repair technique. Preoperative diagnosis, tear assessment, and grading of fatty infiltration of the cuff muscles were based on arthro–computed tomography evaluation. The technique passes 2 sutures from the medial to lateral margin of the tear, with a knotless suture anchor for tendon-to-bone fixation. The proposed technique seems to reduce tensile strain on the repaired tendon, can reconstruct the rotator cuff cable, and can attain the balanced pull of the tendon in a medial-to-lateral fashion. The over-under lacing suture technique is both simple and reproducible. This technique may achieve the goals of margin convergence with satisfactory preliminary clinical results for patients with massive rotator cuff tears. PMID:26697304

  2. Angiogenesis and osteogenesis in an orthopedically expanded suture

    NASA Technical Reports Server (NTRS)

    Chang, H. N.; Garetto, L. P.; Potter, R. H.; Katona, T. R.; Lee, C. H.; Roberts, W. E.

    1997-01-01

    The purpose of this study was to examine the angiogenic and the subsequent osteogenic responses during a 96-hour time-course after sutural expansion. Fifty rats were divided into: (1) a control group that received only angiogenic induction through injection of 5 ng/gm recombinant human endothelial cell growth factor (rhECGF); (2) an experimental group that received orthopedic expansion and rhECGF; (3) a sham group that received expansion and sodium chloride (NaCl) injection; and (4) a baseline group that received no expansion or injection. All rats were injected with 3H-thymidine (1.0 microCi/gm) 1 hour before death to label the DNA of S-phase cells. Demineralized sections (4 microm thick) were stained with hematoxylin and eosin. Angiogenesis and cell migration were analyzed with a previously established cell kinetics model. Analysis of variance was used to test the hypothesis that enhancement of angiogenesis stimulates reestablishment of osteogenic capability. Blood vessel number, area, and endothelial cell-labeled index significantly increased in experimental groups, but no difference was found between control and baseline groups. Labeled-pericyte index and activated pericyte numbers in the experimental group were also higher than in the sham groups. These results show that supplemental rhECGF enhances angiogenesis in expanded sutures but not in nonexpanded sutures. Data also suggest that pericytes are the source of osteoblasts in an orthopedically expanded suture.

  3. Comparison of Subcuticular Suture Materials in Cesarean Skin Closure

    PubMed Central

    Hasdemir, Pınar Solmaz; Guvenal, Tevfik; Ozcakir, Hasan Tayfun; Koyuncu, Faik Mumtaz; Dinc Horasan, Gonul; Erkan, Mustafa; Oruc Koltan, Semra

    2015-01-01

    Aim. Comparison of the rate of wound complications, pain, and patient satisfaction based on used subcuticular suture material. Methods. A total of 250 consecutive women undergoing primary and repeat cesarean section with low transverse incision were prospectively included. The primary outcome was wound complication rate including infection, dehiscence, hematoma, and hypertrophic scar formation within a 6-week period after operation. Secondary outcomes were skin closure time, the need for use of additional analgesic agent, pain score on numeric rating scale, cosmetic score, and patient scar satisfaction scale. Results. Absorbable polyglactin was used in 108 patients and nonabsorbable polypropylene was used in 142 patients. Wound complication rates were similar in primary and repeat cesarean groups based on the type of suture material. Skin closure time is longer in nonabsorbable suture material group in both primary and repeat cesarean groups. There was no difference between groups in terms of postoperative pain, need for additional analgesic use, late phase pain, and itching at the scar. Although the cosmetic results tended to be better in the nonabsorbable group in primary surgery patients, there was no significant difference in the visual satisfaction of the patients. Conclusions. Absorbable and nonabsorbable suture materials are comparable in cesarean section operation skin closure. PMID:26413566

  4. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830...

  5. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Natural nonabsorbable silk surgical suture. 878.5030 Section 878.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  6. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  7. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Natural nonabsorbable silk surgical suture. 878.5030 Section 878.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  8. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Natural nonabsorbable silk surgical suture. 878.5030 Section 878.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  9. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830...

  10. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830...

  11. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  12. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.5020...

  13. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Natural nonabsorbable silk surgical suture. 878.5030 Section 878.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  14. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Natural nonabsorbable silk surgical suture. 878.5030 Section 878.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  15. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830...

  16. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830...

  17. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.5020...

  18. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin...

  19. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin...

  20. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin...

  1. The fluorinated (10, 0) boron nitride nanotube: a computational nuclear magnetic resonance and nuclear quadrupole resonance study.

    PubMed

    Seif, Ahmad; Boshra, Asadollah; Bodaghi, Ali

    2010-01-01

    Quantum chemical calculations at the level of density functional theory (DFT) were carried out to investigate the influence of fluorination boron and nitrogen nuclear magnetic resonance (NMR) and also nuclear quadrupole resonance (NQR) parameters in the (10, 0) single-wall boron nitride nanotube (SWBNNT). To achieve this aim three models of (10, 0) boron nitride nanotubes (BNNTs), raw and two F-attached (exohedral and endohedral) derivatives were studied. The results of calculations showed that while the boron atom chemically bonded to F atom has the largest chemical shielding isotropy (CSI); it has the smallest quadrupole coupling constant (CQ) value among the other boron nuclei.

  2. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Vinylidene chloride copolymer coatings for nylon film. 175.360 Section 175.360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: ADHESIVES...

  3. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Vinylidene chloride copolymer coatings for nylon film. 175.360 Section 175.360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: ADHESIVES...

  4. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Vinylidene chloride copolymer coatings for nylon film. 175.360 Section 175.360 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) FOOD FOR HUMAN CONSUMPTION (CONTINUED) INDIRECT FOOD ADDITIVES: ADHESIVES...

  5. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... is applied as a continuous film over one or both sides of a base film produced from nylon resins... produced by copolymerizing vinylidene chloride with one or more of the monomers acrylic acid, acrylonitrile, ethyl acrylate, methacrylic acid, methyl acrylate, methyl methacrylate (CAS Reg. No. 80-62-6;...

  6. Tensile testing of nylon and Kevlar parachute materials under Federal specified temperature and relative humidity conditions

    SciTech Connect

    Botner, W.T.

    1980-01-01

    A small 10-ft x 12-ft temperature and relative humidity controlled room for tensile testing of parachute materials is presented. Tensile tests of nylon and Kevlar parachute materials indicate there is a negligible change in break strength of test samples soaked in the controlled environment vs samples soaked in ambient conditions.

  7. The nylon scintillator containment vessels for the Borexino solar neutrino experiment

    NASA Astrophysics Data System (ADS)

    Cadonati, L.; Calaprice, F.; Galbiati, C.; Pocar, A.; Shutt, T.

    2014-06-01

    The neutrino event rate in the Borexino scintillator is very low ( 0.5 events per day per ton) and concentrated in an energy region well below the 2.6 MeV threshold of natural radioactivity. The intrinsic radioactive contaminants in the photomultipliers (PMTs), in the Stainless Steel Sphere, and in other detector components, play special requirements on the system required to contain the scintillator. The liquid scintillator must be shielded from the Stainless Steel Sphere and from the PMTs by a thick barrier of buffer fluid. The fluid barrier, in addition, needs to be segmented in order to contain migration of radon and daughters emanated by the Stainless Steel Sphere and by the PMTs. These requirements were met by designing and building two spherical vessel made of thin nylon film. The inner vessel contains the scintillator, separating it from the surrounding buffer. The buffer region itself is divided into two concentric shells by the second, outer nylon vessel. In addition, the two nylon vessels must satisfy stringent requirements for radioactivity and for mechanical, optical and chemical properties. This paper describes the requirements of the the nylon vessels for the Borexino experiment and offers a brief overview of the construction methods adopted to meet those requirements.

  8. Conductive nylon fabric through in situ synthesis of nano-silver: Preparation and characterization.

    PubMed

    Montazer, M; Komeily Nia, Z

    2015-11-01

    A simple, green and low cost method based on Tollens' reagent is presented to synthesize a nano-conductive silver layer on nylon 6 fabric. The nylon fabric was first treated with potassium permanganate to oxidize fabric surface and thereby, increasing the number of assembled particles on the fabric surface. SEM images indicated distribution of silver nanoparticles on the fabric surface and formation of nanolayer on the fiber surface. EDX and XRD patterns confirmed assembling silver nanoparticles on the nylon fibers. The treated fabrics displayed a very low electrical resistivity i.e. 4.5Ω/sq. Furthermore, the fabric color was indicated by a reflectance spectrophotometer in order to study the effects of the synthesized nanoparticles on the fabric color. It is also indicated that oxidation process has no significant influence on the mechanical properties of the fabric, and nano-treatment revenged the negative effect of oxidation of nylon fabric. Moreover, silver nanoparticles imparted reasonable antibacterial properties to the fabric against Staphylococcus aureus. PMID:26249599

  9. Ultraviolet-induced irreversible tensile actuation of diacetylene/nylon microfibers

    NASA Astrophysics Data System (ADS)

    Chun, Kyoung-Yong; Choi, Changsoon; Baughman, Ray H.; Kim, Seon Jeong

    2016-07-01

    Photomechanically irreversible tensile-actuated diacetylene-embedding nylon 6/6 microfibers were investigated. 10,12-pentacosadiynoic acid (PCDA) monomer, which have conventionally provided a visual color change by temperature and photo-driven stimuli, was embedded in nylon 6/6 microfibers by wet spinning. By ultraviolet (UV) (254 nm) exposure, we observed irreversible tensile actuation (contraction) of linear (untwisted) and helical (twisted) structural microfibers. The tensile contraction of twisted nylon 6/6-PCDA microfiber containing10 mM PCDA was reached to ∼2% at 60 °C. Such irreversible tensile contraction can be promoted by volume contraction of PCDA monomers during UV exposure along with irregular structural deformation containing gauche conformation with increasing temperature. The kinetics of tensile contraction with temperature and time were shown by the Arrhenius plots. The activation energies were 34.3–35.7 kJ mol‑1 as increasing the concentration of PCDA, implies that the nylon 6/6-PCDA microfibers could be applied to show time-temperature integrated device.

  10. Conductive nylon fabric through in situ synthesis of nano-silver: Preparation and characterization.

    PubMed

    Montazer, M; Komeily Nia, Z

    2015-11-01

    A simple, green and low cost method based on Tollens' reagent is presented to synthesize a nano-conductive silver layer on nylon 6 fabric. The nylon fabric was first treated with potassium permanganate to oxidize fabric surface and thereby, increasing the number of assembled particles on the fabric surface. SEM images indicated distribution of silver nanoparticles on the fabric surface and formation of nanolayer on the fiber surface. EDX and XRD patterns confirmed assembling silver nanoparticles on the nylon fibers. The treated fabrics displayed a very low electrical resistivity i.e. 4.5Ω/sq. Furthermore, the fabric color was indicated by a reflectance spectrophotometer in order to study the effects of the synthesized nanoparticles on the fabric color. It is also indicated that oxidation process has no significant influence on the mechanical properties of the fabric, and nano-treatment revenged the negative effect of oxidation of nylon fabric. Moreover, silver nanoparticles imparted reasonable antibacterial properties to the fabric against Staphylococcus aureus.

  11. Degradation mechanisms of nylon separator materials for a nickel-cadmium cell in KOH electrolytes

    SciTech Connect

    Lim, H.S.; Margerum, J.D.; Verzwyvelt, S.A.; Lackner, A.M.; Knechtli, R.C.

    1989-03-01

    Degradation reactions of a nylon 6 battery separator material have been studied in 4-34% aqueous KOH electrolytes at 35/sup 0/-110/sup 0/C. In a Ni/Cd cell, this degradation involves a slow hydrolysis reaction followed by fast electrochemical oxidations of the hydrolysis reaction products. Arrhenius activation energy of the hydrolysis reaction in 34% KOH was 20.0 +- 0.3 kcal/mole. A plot of the hydrolysis rate at 100/sup 0/C vs. hydroxyl ion concentration gave a rate maximum at about 16% KOH, and the mechanism for this effect is discussed. Electrochemical oxidations of the hydrolysis product, 6-aminocaproate ion, appear to proceed rapidly in several sequential steps at a nickel oxide electrode. In a Ni/Cd cell, the combination of nylon separator hydrolysis followed by electrochemical oxidation of the products can seriously degrade the battery lifetime. The rate of the hydrolysis of nylon 66 separator material was approximately one half of that of the nylon 6 material.

  12. One-step synthesis of silver nanoparticle-filled Nylon 6 nanofibers and their antibacterial properties

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A novel and facile one-step approach to in situ synthesize silver nanoparticle-filled nylon 6 nanofibers by electrospinning is reported. The method does not need post-treatments and can be carried out at ambient conditions without using additional chemicals. It employs the electrospinning solvent as...

  13. Ultraviolet-induced irreversible tensile actuation of diacetylene/nylon microfibers

    NASA Astrophysics Data System (ADS)

    Chun, Kyoung-Yong; Choi, Changsoon; Baughman, Ray H.; Kim, Seon Jeong

    2016-07-01

    Photomechanically irreversible tensile-actuated diacetylene-embedding nylon 6/6 microfibers were investigated. 10,12-pentacosadiynoic acid (PCDA) monomer, which have conventionally provided a visual color change by temperature and photo-driven stimuli, was embedded in nylon 6/6 microfibers by wet spinning. By ultraviolet (UV) (254 nm) exposure, we observed irreversible tensile actuation (contraction) of linear (untwisted) and helical (twisted) structural microfibers. The tensile contraction of twisted nylon 6/6-PCDA microfiber containing10 mM PCDA was reached to ˜2% at 60 °C. Such irreversible tensile contraction can be promoted by volume contraction of PCDA monomers during UV exposure along with irregular structural deformation containing gauche conformation with increasing temperature. The kinetics of tensile contraction with temperature and time were shown by the Arrhenius plots. The activation energies were 34.3-35.7 kJ mol-1 as increasing the concentration of PCDA, implies that the nylon 6/6-PCDA microfibers could be applied to show time-temperature integrated device.

  14. Swabbing for respiratory viral infections in older patients: a comparison of rayon and nylon flocked swabs.

    PubMed

    Hernes, S S; Quarsten, H; Hagen, E; Lyngroth, A L; Pripp, A H; Bjorvatn, B; Bakke, P S

    2011-02-01

    The purpose of this study was to compare the sampling efficacy of rayon swabs and nylon flocked swabs, and of oropharyngeal and nasopharyngeal specimens for the detection of respiratory viruses in elderly patients. Samples were obtained from patients 60 years of age or above who were newly admitted to Sorlandet Hospital Arendal, Norway. The patients were interviewed for current symptoms of a respiratory tract infection. Using rayon swabs and nylon flocked swabs, comparable sets of mucosal samples were harvested from the nasopharynx and the oropharynx. The samples were analysed using real-time polymerase chain reaction (PCR) methods. A total of 223 patients (mean age 74.9 years, standard deviation [SD] 9.0 years) were swabbed and a virus was recovered from 11% of the symptomatic patients. Regardless of the sampling site, a calculated 4.8 times higher viral load (95% confidence interval [CI] 1.3-17, p = 0.017) was obtained using the nylon flocked swabs as compared to the rayon swabs. Also, regardless of the type of swab, a calculated 19 times higher viral load was found in the samples from the nasopharynx as compared to the oropharynx (95% CI 5.4-67.4, p < 0.001). When swabbing for respiratory viruses in elderly patients, nasopharyngeal rather than oropharyngeal samples should be obtained. Nylon flocked swabs appear to be more efficient than rayon swabs.

  15. The use of suture anchors to repair the ruptured quadriceps tendon.

    PubMed

    Bushnell, Brandon D; Whitener, George B; Rubright, James H; Creighton, R Alexander; Logel, Kevin J; Wood, Mark L

    2007-07-01

    Quadriceps tendon rupture is an incapacitating injury that usually requires surgical repair. Traditional repair methods involve transpatellar suture tunnels, but recent reports have introduced the idea of using suture anchors to repair the ruptured tendon. We present 5 cases of our technique of using suture anchors to repair the ruptured quadriceps tendon.

  16. Scanning electron microscope and micro-CT evaluation of cranial sutures in health and disease.

    PubMed

    Anderson, Peter J; Netherway, David J; David, David J; Self, Peter

    2006-09-01

    Current knowledge of suture biology has been ascertained as a result of morphological studies of normal cranial sutures (and rarely those undergoing craniosynostosis). These were initially undertaken often using histological investigations, or more recently using CT scans, as investigative tools, but have often used animal models. However, recent technological advances have provided the potential to refine our understanding of the ultrastructure by the use of new advanced scanning technology, which offers the possibility of more detailed resolution. Our aim was to undertake detailed scans of normal, fusing and fused sutures from patients with craniosynosotosis affecting different sutures, to study the detailed structure at different stages of the fusion process using a modern micro-CT scanner and a microanalytical scanning electron microscope. We wished to include in our study all the human sutures because previous studies have mostly been undertaken using the sagittal suture. Ten sutures from seven patients have revealed a complex ultra-structural arrangement. The different patterns of bone ridging seen on the ectocranial and endocranial surfaces of the fused sagittal suture were not repeated on closer inspection of either fused coronal or lambdoid sutures. Elemental analysis confirmed that the amount of calcium increased and the amount of carbon decreased as sampled areas moved away from the suture margin. We conclude that scanning allowed detailed assessment and revealed the complex arrangement of the structure of the human cranial sutures and those undergoing the process of craniosynostosis, with some differences in final structure depending on the affected suture.

  17. A transducer for measuring force on surgical sutures

    PubMed Central

    Witte, Thomas H.; Cheetham, Jonathan; Rawlinson, Jeremy J.; Soderholm, L. Vince; Ducharme, Norm G.

    2010-01-01

    The objective of this study was to validate, both in vitro and in an ex vivo model, a technique for the measurement of forces exerted on surgical sutures. For this purpose, a stainless steel E-type buckle force transducer was designed and constructed. A strain gauge was mounted on the central beam of the transducer to measure transducer deformation. The transducer was tested and calibrated on a single strand of surgical suture during cyclic loading. Further validation was performed using a previously published cadaveric model of laryngoplasty in the horse. Linear regression of transducer output with actual force during calibration tests resulted in mean R2 values of 1.00, 0.99, and 0.99 for rising slope, falling slope, and overall slope, respectively. The R2 was not less than 0.96 across an average of 75 cycles per test. The difference between rising slope and falling slope was 4%. Over 45 846 samples, the predicted force from transducer output showed a mean error of 4%. In vitro validation produced an adjusted R2 of 0.99 when the force on the suture was regressed against translaryngeal pressure in a mixed-effects model. E-type buckle force transducers showed a highly linear output over a physiological force range when applied to surgical suture in vitro and in an ex vivo model of laryngoplasty. With appropriate calibration and short-term in vivo implantation, these transducers may advance our knowledge of the mechanisms of success and failure of techniques, such as laryngoplasty, that use structural suture implants. PMID:21197230

  18. Effects of Citalopram on Sutural and Calvarial Cell Processes

    PubMed Central

    Durham, Emily; Jen, Serena; Wang, Lin; Nasworthy, Joseph; Elsalanty, Mohammed; Weinberg, Seth; Yu, Jack; Cray, James

    2015-01-01

    The use of selective serotonin reuptake inhibitors (SSRIs) for the treatment of depression during pregnancy is suggested to increase the incidence of craniofacial abnormalities including craniosynostosis. Little is known about this mechanism, however based on previous data we propose a mechanism that affects cell cycle. Excessive proliferation, and reduction in apoptosis may lead to hyperplasia within the suture that may allow for differentiation, bony infiltration, and fusion. Here we utilized in vivo and in vitro analysis to investigate this proposed phenomenon. For in vivo analysis we used C57BL–6 wild-type breeders treated with a clinical dose of citalopram during the third trimester of pregnancy to produce litters exposed to the SSRI citalopram in utero. At post-natal day 15 sutures were harvested from resulting pups and subjected to histomorphometric analysis for proliferation (PCNA) and apoptosis (TUNEL). For in vitro studies, we used mouse calvarial pre-osteoblast cells (MC3T3-E1) to assess proliferation (MTS), apoptosis (Caspase 3/7-activity), and gene expression after exposure to titrated doses of citalopram. In vivo analysis for PCNA suggested segregation of effect by location, with the sagittal suture, showing a statistically significant increase in proliferative response. The coronal suture was not similarly affected, however there was a decrease in apoptotic activity at the dural edge as compared to the periosteal edge. No differences in apoptosis by suture or area due to SSRI exposure were observed. In vitro results suggest citalopram exposure increased proliferation and proliferative gene expression, and decreased apoptosis of the MC3T3-E1 cells. Decreased apoptosis was not confirmed in vivo however, an increase in proliferation without a concomitant increase in apoptosis is still defined as hyperplasia. Thus prenatal SSRI exposure may exert a negative effect on post-natal growth through a hyperplasia effect at the cranial growth sites perhaps

  19. In situ Polymerization of Multi-Walled Carbon Nanotube/Nylon-6 Nanocomposites and Their Electrospun Nanofibers.

    PubMed

    Saeed, Khalid; Park, Soo-Young; Haider, Sajjad; Baek, Jong-Beom

    2009-01-01

    Multiwalled carbon nanotube/nylon-6 nanocomposites (MWNT/nylon-6) were prepared by in situ polymerization, whereby functionalized MWNTs (F-MWNTs) and pristine MWNTs (P-MWNTs) were used as reinforcing materials. The F-MWNTs were functionalized by Friedel-Crafts acylation, which introduced aromatic amine (COC(6)H(4)-NH(2)) groups onto the side wall. Scanning electron microscopy (SEM) images obtained from the fractured surfaces of the nanocomposites showed that the F-MWNTs in the nylon-6 matrix were well dispersed as compared to those of the P-MWNTs. Both nanocomposites could be electrospun into nanofibers in which the MWNTs were embedded and oriented along the nanofiber axis, as confirmed by transmission electron microscopy. The specific strength and modulus of the MWNTs-reinforced nanofibers increased as compared to those of the neat nylon-6 nanofibers. The crystal structure of the nylon-6 in the MWNT/nylon-6 nanofibers was mostly gamma-phase, although that of the MWNT/nylon-6 films, which were prepared by hot-pressing the pellets between two aluminum plates and then quenching them in icy water, was mostly alpha-phase, indicating that the shear force during electrospinning might favor the gamma-phase, similarly to the conventional fiber spinning. PMID:20596470

  20. Crystalline Morphology and Polymorphic Phase Transitions in Electrospun Nylon 6 Nanofibers.

    PubMed

    Liu, Yi; Cui, Li; Guan, Fangxiao; Gao, Yi; Hedin, Nyle E; Zhu, Lei; Fong, Hao

    2007-01-01

    Uniform nylon 6 nanofibers with diameters around 200 nm were prepared by electrospinning. Polymorphic phase transitions and crystal orientation of nylon 6 in unconfined (i.e., as-electrospun) and a high T(g) (340 degrees C) polyimide confined nanofibers were studied. Similar to melt-spun nylon 6 fibers, electrospun nylon 6 nanofibers also exhibited predominant, meta-stable gamma crystalline form, and the gamma-crystal (chain) axes preferentially oriented parallel to the fiber axis. Upon annealing above 150 degrees C, gamma-form crystals gradually melted and recrystallized into the thermodynamically stable alpha-form crystals, which ultimately melted at 220 degrees C. Release of surface tension accompanied this melt-recrystallization process, as revealed by differential scanning calorimetry. For confined nanofibers, both the melt-recrystallization and surface tension release processes were substantially depressed; gamma-form crystals did not melt and recrystallize into alpha-form crystals until 210 degrees C, only 10 degrees C below the T(m) at 220 degrees C. After complete melting of nano-confined crystals at 240 degrees C and recrystallization at 100 degrees C, only alpha-form crystals oriented perpendicular to the nanofiber axis were obtained. In the polyimide-confined nanofibers, the Brill transition (from the monoclinic alpha-form to a high temperature monoclinic form) was observed at 180-190 degrees C, which was at least 20 degrees C higher than that in unconfined nylon 6 at approximately 160 degrees C. This, again, was attributed to the confinement effect.

  1. Effect of random/aligned nylon-6/MWCNT fibers on dental resin composite reinforcement.

    PubMed

    Borges, Alexandre L S; Münchow, Eliseu A; de Oliveira Souza, Ana Carolina; Yoshida, Takamitsu; Vallittu, Pekka K; Bottino, Marco C

    2015-08-01

    The aims of this study were (1) to synthesize and characterize random and aligned nanocomposite fibers of multi-walled carbon nanotubes (MWCNT)/nylon-6 and (2) to determine their reinforcing effects on the flexural strength of a dental resin composite. Nylon-6 was dissolved in hexafluoropropanol (10 wt%), followed by the addition of MWCNT (hereafter referred to as nanotubes) at two distinct concentrations (i.e., 0.5 or 1.5 wt%). Neat nylon-6 fibers (without nanotubes) were also prepared. The solutions were electrospun using parameters under low- (120 rpm) or high-speed (6000 rpm) mandrel rotation to collect random and aligned fibers, respectively. The processed fiber mats were characterized by scanning (SEM) and transmission (TEM) electron microscopies, as well as by uni-axial tensile testing. To determine the reinforcing effects on the flexural strength of a dental resin composite, bar-shaped (20×2×2 mm(3)) resin composite specimens were prepared by first placing one increment of the composite, followed by one strip of the mat, and one last increment of composite. Non-reinforced composite specimens were used as the control. The specimens were then evaluated using flexural strength testing. SEM was done on the fractured surfaces. The data were analyzed using ANOVA and the Tukey׳s test (α=5%). Nanotubes were successfully incorporated into the nylon-6 fibers. Aligned and random fibers were obtained using high- and low-speed electrospinning, respectively, where the former were significantly (p<0.001) stronger than the latter, regardless of the nanotubes׳ presence. Indeed, the dental resin composite tested was significantly reinforced when combined with nylon-6 fibrous mats composed of aligned fibers (with or without nanotubes) or random fibers incorporated with nanotubes at 0.5 wt%.

  2. Vapor-liquid equilibria for the systems difluoromethane + chlorodifluoromethane, difluoromethane + dichlorodifluoromethane, and difluoromethane + chloromethane at 10.0 C

    SciTech Connect

    Kang, Y.W.; Chung, K.Y.

    1996-05-01

    Isothermal vapor-liquid equilibria for the three binary systems (difluoromethane + chlorodifluoromethane, difluoromethane + dichlorodifluoromethane, and difluoromethane + chloromethane) have been measured at 10.0 C. The experimental data for the binary systems are correlated with the Wilson equation and the relevant parameters are presented. The difluoromethane + dichlorodifluoromethane system forms a minimum boiling azeotrope, but the others do not.

  3. INTRASYNOVIAL FLEXOR TENDON REPAIR: A BIOMECHANICAL STUDY OF VARIATIONS IN SUTURE APPLICATION IN HUMAN CADAVERA

    PubMed Central

    Nelson, GN; Potter, R; Ntouvali, E; Silva, MJ; Boyer, MI; Gelberman, RH; Thomopoulos, S

    2013-01-01

    To improve the functional outcomes of intrasynovial tendon suture, prior experiments evaluated individual technical modifications used in the repair process. Few studies, however, have assessed the combinatorial effects of those suture modifications in an integrated biomechanical manner, including a sample size sufficient to make definitive observations on repair technique. 256 flexor tendon repairs were performed in cadavera, and biomechanical properties were determined. The effects of five factors for flexor tendon repair were tested: core suture caliber (4-0 or 3-0), number of sutures crossing the repair site (4- or 8-strand), core suture purchase (0.75 cm or 1.2 cm), peripheral suture caliber (6-0 or 5-0), and peripheral suture purchase (superficial or 2 mm). Significant factors affecting the properties of the repair were the number of core suture strands and the peripheral suture purchase. The least significant factors were core suture purchase and peripheral suture caliber. The choice of core suture caliber affected the properties of repair marginally. Based on these results, we recommend that surgeons continue to focus on multi-strand repair methods, as the properties of 8-strand repairs were far better than those of 4-strand repairs. To resist gap formation and enhance repair strength, a peripheral suture with 2mm purchase is also recommended. Finally, since core suture caliber affected some biomechanical properties, including the failure mode, a 3-0 suture could be considered, provided that future in vivo studies can confirm that gliding properties are not adversely influenced. PMID:22457145

  4. Effect of recombinant human platelet-derived growth factor-BB-coated sutures on Achilles tendon healing in a rat model: A histological and biomechanical study

    PubMed Central

    Cummings, Stephen H; Grande, Daniel A; Hee, Christopher K; Kestler, Hans K; Roden, Colleen M; Shah, Neil V; Razzano, Pasquale; Dines, David M; Chahine, Nadeen O

    2012-01-01

    Purpose: Repairing tendon injuries with recombinant human platelet-derived growth factor-BB has potential for improving surgical outcomes. Augmentation of sutures, a critical component of surgical tendon repair, by coating with growth factors may provide a clinically useful therapeutic device for improving tendon repair. Therefore, the purpose of this study was to (a) coat Vicryl sutures with a defined dose of recombinant human platelet-derived growth factor-BB without additional coating excipients (e.g. gelatin), (b) quantify the recombinant human platelet-derived growth factor-BB released from the suture, and (c) use the recombinant human platelet-derived growth factor-BB-coated sutures to enhance tendon repair in a rat Achilles tendon transection model. Methods: Vicryl sutures were coated with 0, 0.3, 1.0, and 10.0 mg/mL concentrations of recombinant human platelet-derived growth factor-BB using a dip-coating process. In vitro release was quantified by an enzyme-linked immunosorbent assay. Acutely transected rat Achilles tendons were repaired using one of the four suture groups (n = 12 per group). Four weeks following repair, the tensile biomechanical and histological (i.e. collagen organization and angiogenesis) properties were determined. Results: A dose-dependent bolus release of recombinant human platelet-derived growth factor-BB occurred within the first hour in vitro, followed by a gradual release over 48 h. There was a significant increase in ultimate tensile strength (p < 0.01) in the two highest recombinant human platelet-derived growth factor-BB dose groups (1.9 ± 0.5 and 2.1 ± 0.5 MPa) relative to controls (1.0 ± 0.2 MPa). The modulus significantly increased (p = 0.031) with the highest recombinant human platelet-derived growth factor-BB dose group (7.2 ± 3.8 MPa) relative to all other groups (control: 3.5 ± 0.9 MPa). No significant differences were identified for the maximum load or stiffness. The histological collagen and angiogenesis scores

  5. Timing of ectocranial suture activity in Gorilla gorilla as related to cranial volume and dental eruption.

    PubMed

    Cray, James; Cooper, Gregory M; Mooney, Mark P; Siegel, Michael I

    2011-05-01

    Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns and a similar suture ontogeny (relative timing of suture fusion during the species ontogeny). This ontogeny includes patency during and after neurocranial expansion with a delayed bony response associated with adaptation to biomechanical forces generated by mastication. Here we investigate these relationships for Gorilla by examining the association among ectocranial suture morphology, cranial volume (as a proxy for neurocranial expansion) and dental development (as a proxy for the length of time that it has been masticating hard foods and exerting such strains on the cranial vault) in a large sample of Gorilla gorilla skulls. Two-hundred and fifty-five Gorilla gorilla skulls were examined for ectocranial suture closure status, cranial volume and dental eruption. Regression models were calculated for cranial volumes by suture activity, and Kendall's tau (a non-parametric measure of association) was calculated for dental eruption status by suture activity. Results suggest that, as reported for Pan and Homo, neurocranial expansion precedes suture synostosis activity. Here, Gorilla was shown to have a strong relationship between dental development and suture activity (synostosis). These data are suggestive of suture fusion extending further into ontogeny than brain expansion, similar to Homo and Pan. This finding allows for the possibility that masticatory forces influence ectocranial suture morphology.

  6. Assessment of the role of sutures in a lizard skull: a computer modelling study

    PubMed Central

    Moazen, Mehran; Curtis, Neil; O'Higgins, Paul; Jones, Marc E.H; Evans, Susan E; Fagan, Michael J

    2008-01-01

    Sutures form an integral part of the functioning skull, but their role has long been debated among vertebrate morphologists and palaeontologists. Furthermore, the relationship between typical skull sutures, and those involved in cranial kinesis, is poorly understood. In a series of computational modelling studies, complex loading conditions obtained through multibody dynamics analysis were imposed on a finite element model of the skull of Uromastyx hardwickii, an akinetic herbivorous lizard. A finite element analysis (FEA) of a skull with no sutures revealed higher patterns of strain in regions where cranial sutures are located in the skull. From these findings, FEAs were performed on skulls with sutures (individual and groups of sutures) to investigate their role and function more thoroughly. Our results showed that individual sutures relieved strain locally, but only at the expense of elevated strain in other regions of the skull. These findings provide an insight into the behaviour of sutures and show how they are adapted to work together to distribute strain around the skull. Premature fusion of one suture could therefore lead to increased abnormal loading on other regions of the skull causing irregular bone growth and deformities. This detailed investigation also revealed that the frontal–parietal suture of the Uromastyx skull played a substantial role in relieving strain compared with the other sutures. This raises questions about the original role of mesokinesis in squamate evolution. PMID:18765341

  7. Assessment of the role of sutures in a lizard skull: a computer modelling study.

    PubMed

    Moazen, Mehran; Curtis, Neil; O'Higgins, Paul; Jones, Marc E H; Evans, Susan E; Fagan, Michael J

    2009-01-01

    Sutures form an integral part of the functioning skull, but their role has long been debated among vertebrate morphologists and palaeontologists. Furthermore, the relationship between typical skull sutures, and those involved in cranial kinesis, is poorly understood. In a series of computational modelling studies, complex loading conditions obtained through multibody dynamics analysis were imposed on a finite element model of the skull of Uromastyx hardwickii, an akinetic herbivorous lizard. A finite element analysis (FEA) of a skull with no sutures revealed higher patterns of strain in regions where cranial sutures are located in the skull. From these findings, FEAs were performed on skulls with sutures (individual and groups of sutures) to investigate their role and function more thoroughly. Our results showed that individual sutures relieved strain locally, but only at the expense of elevated strain in other regions of the skull. These findings provide an insight into the behaviour of sutures and show how they are adapted to work together to distribute strain around the skull. Premature fusion of one suture could therefore lead to increased abnormal loading on other regions of the skull causing irregular bone growth and deformities. This detailed investigation also revealed that the frontal-parietal suture of the Uromastyx skull played a substantial role in relieving strain compared with the other sutures. This raises questions about the original role of mesokinesis in squamate evolution.

  8. Cranial sutures work collectively to distribute strain throughout the reptile skull

    PubMed Central

    Curtis, Neil; Jones, M. E. H.; Evans, S. E.; O'Higgins, P.; Fagan, M. J.

    2013-01-01

    The skull is composed of many bones that come together at sutures. These sutures are important sites of growth, and as growth ceases some become fused while others remain patent. Their mechanical behaviour and how they interact with changing form and loadings to ensure balanced craniofacial development is still poorly understood. Early suture fusion often leads to disfiguring syndromes, thus is it imperative that we understand the function of sutures more clearly. By applying advanced engineering modelling techniques, we reveal for the first time that patent sutures generate a more widely distributed, high level of strain throughout the reptile skull. Without patent sutures, large regions of the skull are only subjected to infrequent low-level strains that could weaken the bone and result in abnormal development. Sutures are therefore not only sites of bone growth, but could also be essential for the modulation of strains necessary for normal growth and development in reptiles. PMID:23804444

  9. Mechanical reinforcement and environmental effects on a nylon-6/clay nanocomposite

    NASA Astrophysics Data System (ADS)

    Shelley, J. Stebbins

    2000-10-01

    Hybridization, or modifying the organic polymers with inorganic constituents, is one method of achieving mechanical property improvements in polymeric materials while preserving processing characteristics. Toyota Central Research developed, and Ube Industries commercialized, one such hybrid nanocomposite: nylon-6/montmorillonite clay. This dissertation explores mechanisms of reinforcement in these nylon-6/clay nanocomposites and studies their degradation by atmospheric pollutants. A 100% improvement in modulus, 77% improvement in yield stress, and 54°C improvement in heat distortion temperature over nylon-6 were observed in extruded 5 wt% clay nanocomposite sheets. Infrared absorption spectrography and dynamic mechanical analysis were used to investigate the mechanisms of reinforcement in these nanocomposites. The improved mechanical properties, increased heat distortion temperature, reduced diffusion rate, and lower susceptibility to degradation in NO x observed where attributed to constraint of polymer chain motion by interaction with clay lamellae. Changes in the loss tangent peak in the glass transition region of the dynamic mechanical data provide an estimate of the volume of chains constrained by complexation of their mid-chain amide oxygen groups with the charged clay lamellae. X-ray analysis, optical microscopy, and light scattering were used to study changes in crystallization due to this complexation. Photomicrographs indicate that the morphology of the crystallites change from spherulitic to planar with the addition of clay. Decreases in diffusion rates of water and total water absorption were demonstrated in immersion experiments. Complexation of nylon-6 with 5 wt% clay reduces the total absorption of water by over 16%. The plane stress fracture toughness of extruded 5 wt% clay nanocomposite was 46% greater than that of nylon-6. The degradation of the nanocomposites in calcium chloride solution and NOx was examined through post exposure residual

  10. [Low colorectal anastomosis: a comparison of manual and mechanical sutures].

    PubMed

    Del Gaudio, A; Boschi, L; Petrin, C; Berardi, M; Accorsi, D

    1993-01-01

    Sixty-three carcinomas of the lower third of the rectum operated of anterior resection with low colorectal or coloanal anastomosis are presented. Handsewn anastomoses were performed in 33 patients, while staplers were used in 30 cases. The average distance of the tumor from the anal verge is 10.8 cm. in hand sutured anastomoses and 7.8 cm. in stapled ones. Dehiscences, stenosis and temporary incontinence are observed more frequently after stapled anastomosis, while the incidence of neoplastic recurrences is higher in sutured anastomosis; hospital stay and mortality are similar in the two series. Our results and literature review show that both techniques are comparable though maintaining their own specific identity and precise indication.

  11. Modification of the Bankart reconstruction using a suture anchor.

    PubMed

    Traina, S M; Holtgrewe, J L; King, S

    1998-01-01

    A prospective study was done to determine the effectiveness of a suture anchor in doing a Modified Bankart Reconstruction on the traumatic unidirectional Bankart lesion shoulder. From 1989 to 1991, 26 patients encompassing 27 shoulders with recurrent instability had modified Bankart reconstructions. A minimum 18-month follow-up was obtained by examination of 24 patients with telephone interviews done on two patients. The average follow-up was 23.6 months. A 93.1% good-to-excellent result was obtained using the Bankart rating scale. There were no failures or complications. The surgeon involved in the study thought the suture anchor facilitated the attachment of the avulsed capsulolabral complex in doing the Bankart procedure.

  12. [Peculiarities of tissue reactions during resorption of biodegradable suture materials].

    PubMed

    Kuznetsova, I V; Maĭborodin, I V; Shevela, A I; Barannik, M I; Manaev, A A; Brombin, A I; Maĭborodina, V I

    2013-01-01

    The reaction of the surrounding tissues to the implantation of biodegradable suture materials (plain catgut threads, DemeTECH polyglactin 910, Surgilactin--polyglactin 910) into the subcutaneous adipose tissue of rats, was studied using light microscopy 1, 2, 6 and 12 months after grafting. It was shown that the tissue reactions to implantation of different biodegradable suture materials followed the general pattern characteristic of wound healing and foreign body reaction. By the first month of observation, in all the animal groups, the stage of traumatic perifocal inflammation was replaced by a proliferative phase with the new growth of the blood vessels and connective tissue. In all the animal groups, there was a trend to reduction of productive inflammation activity from the 1st month till the 12th month. By the 12th month the total degeneration of the material with full recovery of structure of surrounding tissues (restitution) was recorded only after the implantation of polyglactin 910 (DemeTECH).

  13. Local tissue reaction to implantation of biodegradable suture materials.

    PubMed

    Kuznetsova, I V; Maiborodin, I V; Shevela, A I; Barannik, M I; Manaev, A A; Brombin, A I; Maiborodina, V I

    2014-07-01

    Morphological changes in tissues adjacent to the implant were studied 1, 2, 6, and 12 months after implantation of biodegradable suture materials (catgut thread, DemeTECH polyfilament thread, and Surgilactin monofilament thread) into subcutaneous fat of rats. Tissue reaction to implantation of different suture materials developed as usual in response to a wound process and to a foreign body. By the end of month 1. the stage of traumatic perifocal inflammation was replaced in all groups by the proliferative phase with formation of new vessels and connective tissue. A trend to reduction of the productive inflammation activity from month 1 to month 12 was noted. Complete degeneration of the material after 12 months with complete recovery of the histoarchitecture of the adjacent tissues (restitution) was detected only after implantation of DemeTECH polyfilament thread.

  14. Isolation and recovery of cellulose from waste nylon/cotton blended fabrics by 1-allyl-3-methylimidazolium chloride.

    PubMed

    Lv, Fangbing; Wang, Chaoxia; Zhu, Ping; Zhang, Chuanjie

    2015-06-01

    Development of a simple process for separating cellulose and nylon 6 from their blended fabrics is indispensable for recycling of waste mixed fabrics. An efficient procedure of dissolution of the fabrics in an ionic liquid 1-allyl-3-methylimidazolium chloride ([AMIM]Cl) and subsequent filtration separation has been demonstrated. Effects of treatment temperature, time and waste fabrics ratio on the recovery rates were investigated. SEM images showed that the cotton cellulose dissolved in [AMIM]Cl while the nylon 6 fibers remained. The FTIR spectrum of regenerated cellulose (RC) was similar with that of virgin cotton fibers, which verified that no other chemical reaction occurred besides breakage of hydrogen bonds during the processes of dissolution and separation. TGA curves indicated that the regenerated cellulose possessed a reduced thermal stability and was effectively removed from waste nylon/cotton blended fabrics (WNCFs). WNCFs were sufficiently reclaimed with high recovery rate of both regenerated cellulose films and nylon 6 fibers.

  15. Biomechanics of the rostrum and the role of facial sutures.

    PubMed

    Rafferty, Katherine L; Herring, Susan W; Marshall, Christopher D

    2003-07-01

    The rostrum is a large diameter, thin-walled tubular structure that receives loads from the teeth. The rostrum can be conceptualized both as a rigid structure and as an assemblage of several bones that interface at sutures. Using miniature pigs, we measured in vivo strains in rostral bones and sutures to gain a better understanding of how the rostrum behaves biomechanically. Strains in the premaxillary and nasal bones were low but the adjacent maxillary-premaxillary, internasal, and intermaxillary suture strains were larger by an order of magnitude. While this finding emphasizes the composite nature of the rostrum, we also found evidence in the maxillary and nasal bones for rigid structural behavior. Namely, maxillary strain is consistent with a short beam model under shear deformation from molar loading. Strain in the nasal bones is only partially supported by a long beam model; rather, a complex pattern of dorsal bending of the rostrum from incisor contact and lateral compression is suggested. Torsion of the maxilla is ruled out due to the bilateral occlusion of pigs and the similar working and balancing side strains, although it may be important in mammals with a unilateral bite. Torsional loading does appear important in the premaxillae, which demonstrate working and balancing side changes in strain orientation. These differences are attributed to asymmetrical incisor contact occurring at the end of the power stroke.

  16. Self-directed practice schedule enhances learning of suturing skills

    PubMed Central

    Safir, Oleg; Williams, Camille K.; Dubrowski, Adam; Backstein, David; Carnahan, Heather

    2013-01-01

    Background Most preoperative surgical training programs experience challenges with the availability of expert surgeons to teach trainees. Some research suggests that trainees may benefit from being allowed to actively shape their learning environments, which could alleviate some of the time and resource pressures in surgical training. The purpose of this study was to investigate the effects of self-directed or prescribed practice schedules (random or blocked) on learning suturing skills. Methods Participants watched an instructional video for simple interrupted, vertical mattress and horizontal mattress suturing then completed a pretest to assess baseline skills. Participants were assigned to 1 of 4 practice groups: self-directed practice schedule, prescribed blocked practice schedule, prescribed random practice schedule or matched to the self-directed group (control). Practice of the skill was followed by a delayed (1 h) posttest. Improvement from pretest to posttest was determined based on differences in performance time and expert-based assessments. Results Analyses revealed a significant effect of group for difference in performance time of the simple interrupted suture. Random practice did not show the expected advantage for skill learning, but there was an advantage of self-directed practice. Conclusion Self-directed practice schedules may be desirable for optimal learning of simple technical skills, even when expert instruction is available. Instructors must also take into account the interaction between task difficulty and conditions of practice to develop ideal training environments. PMID:24284153

  17. Terranes and suture zones in east central Alaska

    NASA Astrophysics Data System (ADS)

    Churkin, M., Jr.; Foster, H. L.; Chapman, R. M.; Weber, F. R.

    1982-05-01

    East central Alaska, with its 17 terranes, forms a part of the mosaic of allochthonous terranes that join the North American and Siberian plates. These terranes range from continental and continental margin, such as the Tatonduk with its thick well-bedded succession of marine shelf rocks, to seamount, arc, and ocean floor terranes. The Yukon crystalline terrane, the largest described here, is a composite of at least four subterranes juxtaposed across the Tintina fault with the Tatonduk terrane, a northwestern extension of the North American plate in Alaska. Inboard of the Yukon crystalline terrane are packets of closely appressed microterranes separated from the Tatonduk and other terranes belonging to North America by major suture zones. These microterranes lie between North America and the mosaic of accretionary terranes that form the more southerly part of Alaska. The most obviously allochthonous microterranes within the suture zones are the Woodchopper Canyon, an Early Devonian basaltic seamount, and the White Mountains, an Ordovician volcanic arc terrane capped by Silurian and Devonian carbonate bank deposits. The nearest counterpart of these terranes is the Alexander terrane in southeastern Alaska. The Tintina fault of Mesozoic and Cenozoic age, like the Denali fault, primarily follows old suture zones that separate terranes. Strike slip faulting developed after collision in places where further convergence was oblique to the terrane margins. Where terranes met head-on, their leading edges lie along a multiple set of high-angle faults that outline microterranes in accretion zones.

  18. Stress and strain analysis on the anastomosis site sutured with either epineurial or perineurial sutures after simulation of sciatic nerve injury☆

    PubMed Central

    Liu, Guangyao; Zhang, Qiao; Jin, Yan; Gao, Zhongli

    2012-01-01

    The magnitude of tensile stress and tensile strain at an anastomosis site under physiological stress is an important factor for the success of anastomosis following suturing in peripheral nerve injury treatment. Sciatic nerves from fresh adult cadavers were used to create models of sciatic nerve injury. The denervated specimens underwent epineurial and perineurial suturing. The elastic modulus (40.96 ± 2.59 MPa) and Poisson ratio (0.37 ± 0.02) of the normal sciatic nerve were measured by strain electrical measurement. A resistance strain gauge was pasted on the front, back, left, and right of the edge of the anastomosis site after suturing. Strain electrical measurement results showed that the stress and strain values of the sciatic nerve following perineurial suturing were lower than those following epineurial suturing. Scanning electron microscopy revealed that the sciatic nerve fibers were disordered following epineurial compared with perineurial suturing. These results indicate that the effect of perineurial suturing in sciatic nerve injury repair is better than that of epineurial suturing. PMID:25538753

  19. Strength of the suture in the epitenon and within the tendon fibres: development of stronger peripheral suture technique.

    PubMed

    Mashadi, Z B; Amis, A A

    1992-04-01

    In tendon repair, the peripheral stitches are usually placed in the epitenon, but it has not yet been defined whether the grasping strength of the sutures in the epitenon and within the tendon fibres are different. The first stage of this work investigated this difference and found that peripheral stitches within cadaveric tendon fibres were 83% stronger than those in the epitenon layer. A new peripheral stitch, based on this finding, has been designed. Mechanical tests of a range of peripheral suture types in vitro found that the new technique gave a resistance to gap formation twice that of the peripheral stitches commonly in use at present and a rupture strength more than three times, while still avoiding eversion problems. PMID:1534111

  20. Healing of the goat anterior cruciate ligament after a new suture repair technique and bioscaffold treatment.

    PubMed

    Nguyen, D Tan; Geel, Jurre; Schulze, Martin; Raschke, Michael J; Woo, Savio L-Y; van Dijk, C Niek; Blankevoort, Leendert

    2013-10-01

    Primary suture repair of the anterior cruciate ligament (ACL) has been used clinically in an attempt to heal the ruptured ACL. The results, however, were not satisfactory, which in retrospect can be attributed to the used suturing technique and the suboptimal healing conditions. These constraining conditions can be improved by introducing a new suturing technique and by using small intestinal submucosa (SIS) as a bioscaffold. It is hypothesized that the suturing technique keep the torn ends together and that SIS enhance and promote the healing of the ACL. The goat was used as the study model. In the Suture group, the left ACL was transected and suture repaired with a new locking suture repair technique (n=5) allowing approximation and fixation under tension. The Suture-SIS group underwent the same procedure with the addition of SIS (n=5). The right ACL served as control. After 12 weeks of healing, anterior-posterior translation and in situ force of the healing ACL were measured, followed by the measurement of the cross-sectional area and structural stiffness. Routine histology was performed on tissue samples. Gross morphology showed that the healing ACL was continuous with collagenous tissue in both groups. The cross-sectional area of the Suture and the Suture-SIS group was 35% and 50% of the intact control, respectively. The anterior-posterior translations at different flexion angles were statistically not different between the Suture group and the Suture-SIS group. Only the in situ force at 30° in the Suture-SIS group was higher than in the Suture group. Tensile tests showed that the stiffness for the Suture group was not different from the Suture-SIS group (31.1±8.1 N/mm vs. 41.9±18.0 N/mm [p>0.05]). Histology showed longitudinally aligned collagen fibers from origo to insertion. More fibroblasts were present in the healing tissue than in the control intact tissue. The study demonstrated the proof of concept of ACL repair in a goat model with a new suture

  1. Effect of antiarrhythmic drugs on In-111-labeled leukocytes: chemotaxis and adherence to nylon wool

    SciTech Connect

    Thakur, M.L.; Walsh, L.J.; Zaret, B.L.; Gottschalk, A.

    1982-02-01

    The influence of lidocaine (L) and procainamide (P) on the chemotactic ability and adherence to nylon wool of In-111-labeled human polymorphonuclear leukocytes (PMNs) was investigated. At the normal therapeutic levels of L (0.022 mM whole blood) or P (0.03 mM whole blood) no change in PMN function was observed. However, at and above five times the aforementioned blood levels of L, significant reduction in the chemotactic ability of PMNs was noted (p less than 0.005). The adverse effects of In-111 radiation appeared insignificant at all L or P concentrations during the 3-hr observation period. The labeled PMNs were resistant to the toxic effects of a higher concentration of P than that of L, and the reduction in PMN chemotaxis and adherence to nylon wool was not apparent until the P concentration reached 1.5 mM.

  2. Enhancement of strength and stiffness of Nylon 6 filaments through carbon nanotubes reinforcement

    NASA Astrophysics Data System (ADS)

    Mahfuz, Hassan; Adnan, Ashfaq; Rangari, Vijay K.; Hasan, Mohammad M.; Jeelani, Shaik; Wright, Wendelin J.; DeTeresa, Steven J.

    2006-02-01

    We report a method to fabricate carbon nanotube reinforced Nylon filaments through an extrusion process. In this process, Nylon 6 and multiwalled carbon nanotubes (MWCNT) are first dry mixed and then extruded in the form of continuous filaments by a single screw extrusion method. Thermo gravimetric analysis (TGA) and differential scanning calorimetry (DSC) studies have indicated that there is a moderate increase in Tg without a discernible shift in the melting endotherm. Tensile tests on single filaments have demonstrated that Young's modulus and strength of the nanophased filaments have increased by 220% and 164%, respectively with the addition of only 1wt.% MWCNTs. SEM studies and micromechanics based calculations have shown that the alignment of MWCNTs in the filaments, and high interfacial shear strength between the matrix and the nanotube reinforcement was responsible for such a dramatic improvement in properties.

  3. Evaluation of anaerobic degradation, biogas and digestate production of cereal silages using nylon-bags.

    PubMed

    Negri, Marco; Bacenetti, Jacopo; Fiala, Marco; Bocchi, Stefano

    2016-06-01

    In this study, the degradation efficiency and the biogas and digestate production during anaerobic digestion were evaluated for the cereal silages most used to feed biogas plants. To this purpose, silages of: maize from the whole plant, maize from the ear, triticale and wheat were digested, inside of nylon bags, in laboratory scale digesters, for 75days. Overall, the test involved 288 nylon bags. After 75days of digestion, the maize ear silage shows the highest degradation efficiency (about 98%) while wheat silage the lowest (about 83%). The biogas production ranges from 438 to 852Nm(3)/t of dry matter for wheat and ear maize silage, respectively. For all the cereal silages, the degradation as well as the biogas production are faster at the beginning of the digestion time. Digestate mass, expressed as percentage of the fresh matter, ranges from 38% to 84% for wheat and maize ear silage, respectively. PMID:26946439

  4. Layered conductive polymer on nylon membrane templates for high performance, thin-film supercapacitor electrodes

    NASA Astrophysics Data System (ADS)

    Shi, HaoTian Harvey; Naguib, Hani E.

    2016-04-01

    Flexible Thin-film Electrochemical Capacitors (ECs) are emerging technology that plays an important role as energy supply for various electronics system for both present era and the future. Intrinsically conductive polymers (ICPs) are promising pseudo-capacitive materials as they feature both good electrical conductivity and high specific capacitance. This study focuses on the construction and characterization of ultra-high surface area porous electrodes based on coating of nano-sized conductive polymer materials on nylon membrane templates. Herein, a novel nano-engineered electrode material based on nylon membranes was presented, which allows the creation of super-capacitor devices that is capable of delivering competitive performance, while maintaining desirable mechanical characteristics. With the formation of a highly conductive network with the polyaniline nano-layer, the electrical conductivity was also increased dramatically to facilitate the charge transfer process. Cyclic voltammetry and specific capacitance results showed promising application of this type of composite materials for future smart textile applications.

  5. Supersonically blown nylon-6 nanofibers entangled with graphene flakes for water purification.

    PubMed

    Lee, Jong-Gun; Kim, Do-Yeon; Mali, Mukund G; Al-Deyab, Salem S; Swihart, Mark T; Yoon, Sam S

    2015-12-01

    Water purification membranes, capable of purifying a few to tens of milliliters of aqueous methylene blue solution in a minute, were produced by supersonically blowing graphene flakes with a nylon-6 polymeric solution. The solution-blown nylon-6 nanofibers became entangled with graphene flakes thereby locking the graphene flakes within the frame of the bendable two-dimensional film structure. This method, which yielded a 5 × 7 cm(2)-sized membrane in less than 10 seconds, is commercially viable owing to fast fabrication and scalability. We show that our water purification device allows a flow rate range of 0.3-4 L h(-1) with a membrane area of just 5 cm(2), under a pressure difference of 0.5-3.5 bar. If the membrane were scaled up to 0.5 m(2), it could provide 300-4000 L h(-1) flow rate, an ample supply for home use. PMID:26514169

  6. Laparoscopic Transcystic Choledochotomy with Primary Suture for Choledocholith

    PubMed Central

    Zhu, Andong; Zhang, Zhibo

    2015-01-01

    Background and Objectives: To investigate the possibility of extracting common bile duct (CBD) stones by laparoscopically inserting choledochoscope through the natural orifice of the cystic duct and a mini-incision on the CBD, and the safety of laparoscopic primary double-layer suture of the cystic duct and CBD. Methods: Laparoscopic transcystic choledochotomy and extraction of stones with primary suture was performed on 194 patients with gallbladder and CBD stones from October 1, 2009, through April 30, 2012. The cystic duct was left at a diameter of 1 to 1.5 cm after removal of the gallbladder. The duct was longitudinally cut at its ventral side to the confluence with the CBD, and the anterior wall of the CBD was also cut longitudinally. A choledochoscope was then inserted via the enlarged opening, and the stones were extracted from the CBD. Finally, the CBD and cystic duct were closed by continuous mucous layer suture and seromuscular Lembert suture, respectively. The cystic duct was ligated close to the CBD and an abdominal drainage tube was placed. Results: All surgical procedures were successfully performed. The caliber at the confluence between the cystic duct and the CBD was 0.3 to 0.8 cm (SD 0.4 ± 0.1 cm), and the mini-incision of the CBD was 0.1 to 1.1 cm (SD 0.3 ± 0.2 cm). Abdominal drainage lasted 3 to 5 days. Magnetic resonance cholangiopancreatography (MRCP) in 55 patients showed no abnormal change in the CBD diameter. Two patients had bile leakage. Another patient had intermittent abdominal pain and jaundice 5 to 7 days postoperatively, and the retained stones spontaneously passed. The postoperative hospital stay was 6 to 13 days (SD 8 ± 2.1 days). Observation of 176 patients (90%) lasting 1 to 30 months (SD 11 ± 8 months) showed no recurrent stones or stricture of the CBD. Conclusion: The surgical procedure of laparoscopic transcystic choledochotomy and extraction of stones with primary suture is feasible and safe. PMID:25848193

  7. Chemisorption of estrone in nylon microfiltration membranes: Adsorption mechanism and potential use for estrone removal from water.

    PubMed

    Han, Jie; Qiu, Wei; Hu, Jiangyong; Gao, Wei

    2012-03-01

    Estrone is a representative steroid estrogen contaminant that has been detected in effluents from sewage treatment facilities, as well as in surface and ground waters. Our study shows that estrone can be readily removed from water via a unique chemisorption mechanism using nylon microfiltration membranes. Experiments on a laboratory in-line filtration system showed instant removal of estrone from 200 μg/l aqueous solutions by 0.45-μm nylon membranes (ca. 35 L per m(2) membrane). Comparisons with 0.45-μm PVDF, PTFE and glass microfiber membranes suggested that the significant estrone adsorption in nylon membrane should be predominately driven by a different mechanism rather than common physical adsorption. Fourier transform infrared spectroscopy study on nylon membranes and a model compound, N-methylacetamide, showed that the significant adsorption originated from the hydrogen bonding between terminal -OH groups on estrone molecules and nucleophile -C=O groups in amide groups of nylon 6,6. The saturated nylon membrane showed very low leachability in ambient water, while it could be effectively regenerated in alkaline or ethanol solutions. Preliminary reusability study showed that the membrane maintained a consistent adsorption capacity for estrone during ten cycles of reuse. The chemisorption-based polymeric adsorption may provide a new alternative approach for removing estrone and potentially other trace organic contaminants from water.

  8. Synergistic effect of nanoclay and EPR-g-MA on the properties of nylon6/EPR blends.

    PubMed

    Mallick, Sumana; Das, Tanya; Das, C K; Khatua, B B

    2009-05-01

    The effect of EPR-g-MA, nanoclay and a combination of the two on phase morphology and properties of (70/30 w/w) nylon6/EPR blends prepared by melt processing technique has been studied. We found that the number average domain diameter (D(n)) of the dispersed EPR phase in the blend decreased in presence of EPR-g-MA, and clay. This observation indicated that nanoclay could be used as an effective compatibilizer in nylon6/EPR blend. X-ray diffraction study and TEM analysis of the blend/clay nanocomposites revealed the delaminated clay morphology and preferential location of the exfoliated clay platelets in nylon6 phase. Thus, selective dispersion of the clay platelets with delaminated morphology in the matrix phase acted as the barrier and thereby prevented the coalescence of dispersed EPR domains during melt processing. However, addition of nanoclay in the blend did not improve the impact property of the blend. Interestingly, the impact strength of the nylon6/EPR/EPR-g-MA/clay blend was much higher than the nylon6/EPR/EPR-g-MA and nylon6/EPR/clay blends at certain compositions with comparable D(n) values. This could be explained by assuming the presence of delaminated clay platelets at the interface, which were stiffer than the polymers. Hence, the bending energy of the interfaces was high.

  9. Effects of increased muscle mass on mouse sagittal suture morphology and mechanics.

    PubMed

    Byron, Craig D; Borke, James; Yu, Jack; Pashley, David; Wingard, Christopher J; Hamrick, Mark

    2004-07-01

    The purpose of this study is to test predicted form-function relationships between cranial suture complexity and masticatory muscle mass and biomechanics in a mouse model. Specifically, to test the hypothesis that increased masticatory muscle mass increases sagittal suture complexity, we measured the fractal dimension (FD), temporalis mass, and temporalis bite force in myostatin-deficient (GDF8(-/-)) mice and wild-type CD-1 mice (all male, 6 months old). Myostatin is a negative regulator of muscle mass, and myostatin-deficient mice show a marked increase in muscle mass compared to normal mice. We predicted that increased sagittal suture complexity would decrease suture stiffness. The data presented here demonstrate that increased suture complexity (measured as FD) was observed in a hypermuscular mouse model (GDF8(-/-)) with significantly increased temporalis muscle mass and bite forces. Hypermuscular mice were also found to possess suture connective tissue that was less stiff (i.e., underwent more displacement before failure occurred) when loaded in tension. By decreasing stiffness, suture complexity apparently helps to dissipate mechanical loads within the cranium that are related to chewing. These results suggest that cranial suture connective tissue locally adapts to functional demands of the biomechanical suture environment. As such, cranial sutures provide a novel model for studies in connective tissue mechanotransduction.

  10. Supersonically blown nylon-6 nanofibers entangled with graphene flakes for water purification

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Gun; Kim, Do-Yeon; Mali, Mukund G.; Al-Deyab, Salem S.; Swihart, Mark T.; Yoon, Sam S.

    2015-11-01

    Water purification membranes, capable of purifying a few to tens of milliliters of aqueous methylene blue solution in a minute, were produced by supersonically blowing graphene flakes with a nylon-6 polymeric solution. The solution-blown nylon-6 nanofibers became entangled with graphene flakes thereby locking the graphene flakes within the frame of the bendable two-dimensional film structure. This method, which yielded a 5 × 7 cm2-sized membrane in less than 10 seconds, is commercially viable owing to fast fabrication and scalability. We show that our water purification device allows a flow rate range of 0.3-4 L h-1 with a membrane area of just 5 cm2, under a pressure difference of 0.5-3.5 bar. If the membrane were scaled up to 0.5 m2, it could provide 300-4000 L h-1 flow rate, an ample supply for home use.Water purification membranes, capable of purifying a few to tens of milliliters of aqueous methylene blue solution in a minute, were produced by supersonically blowing graphene flakes with a nylon-6 polymeric solution. The solution-blown nylon-6 nanofibers became entangled with graphene flakes thereby locking the graphene flakes within the frame of the bendable two-dimensional film structure. This method, which yielded a 5 × 7 cm2-sized membrane in less than 10 seconds, is commercially viable owing to fast fabrication and scalability. We show that our water purification device allows a flow rate range of 0.3-4 L h-1 with a membrane area of just 5 cm2, under a pressure difference of 0.5-3.5 bar. If the membrane were scaled up to 0.5 m2, it could provide 300-4000 L h-1 flow rate, an ample supply for home use. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06549f

  11. Emergence of nylon oligomer degradation enzymes in Pseudomonas aeruginosa PAO through experimental evolution.

    PubMed Central

    Prijambada, I D; Negoro, S; Yomo, T; Urabe, I

    1995-01-01

    Through selective cultivation with 6-aminohexanoate linear dimer, a by-product of nylon-6 manufacture, as the sole source of carbon and nitrogen, Pseudomonas aeruginosa PAO, which initially has no enzyme activity to degrade this xenobiotic compound, was successfully expanded in its metabolic ability. Two new enzyme activities, 6-aminohexanoate cyclic dimer hydrolase and 6-aminohexanoate dimer hydrolase, were detected in the adapted strains. PMID:7646041

  12. Screening Nylon-3 Polymers, a New Class of Cationic Amphiphiles, for siRNA Delivery

    PubMed Central

    2015-01-01

    Amphiphilic nucleic acid carriers have attracted strong interest. Three groups of nylon-3 copolymers (poly-β-peptides) possessing different cationic/hydrophobic content were evaluated as siRNA delivery agents in this study. Their ability to condense siRNA was determined in SYBR Gold assays. Their cytotoxicity was tested by MTT assays, their efficiency of delivering Alexa Fluor-488-labeled siRNA intracellularly in the presence and absence of uptake inhibitors was assessed by flow cytometry, and their transfection efficacies were studied by luciferase knockdown in a cell line stably expressing luciferase (H1299/Luc). Endosomal release was determined by confocal laser scanning microscopy and colocalization with lysotracker. All polymers efficiently condensed siRNA at nitrogen-to-phosphate (N/P) ratios of 5 or lower, as reflected in hydrodynamic diameters smaller than that at N/P 1. Although several formulations had negative zeta potentials at N/P 1, G2C and G2D polyplexes yielded >80% uptake in H1299/Luc cells, as determined by flow cytometry. Luciferase knockdown (20–65%) was observed after transfection with polyplexes made of the high molecular weight polymers that were the most hydrophobic. The ability of nylon-3 polymers to deliver siRNA intracellularly even at negative zeta potential implies that they mediate transport across cell membranes based on their amphiphilicity. The cellular uptake route was determined to strongly depend on the presence of cholesterol in the cell membrane. These polymers are, therefore, very promising for siRNA delivery at reduced surface charge and toxicity. Our study identified nylon-3 formulations at low N/P ratios for effective gene knockdown, indicating that nylon-3 polymers are a new, promising type of gene delivery agent. PMID:25437915

  13. Laser-optical treatment for toothbrush bristles (nylon, synthetic, and polymeric materials, etc.)

    NASA Astrophysics Data System (ADS)

    Ma, Yangwu

    1994-08-01

    On the basis of the principle of laser radiation and materials interaction, a laser-optical treatment method for toothbrush bristles (nylon et al., synthetic and polymeric materials) is provided. In this process, laser irradiation is stopped during melting and followed by cooling, so the free end of each bristle of toothbrush is formed for a smooth globe. The toothbrush with laser-optical end-globed bristles have many remarkable functions.

  14. Electrospun nitrocellulose and nylon: Design and fabrication of novel high performance platforms for protein blotting applications

    PubMed Central

    Manis, Ashley E; Bowman, James R; Bowlin, Gary L; Simpson, David G

    2007-01-01

    Background Electrospinning is a non-mechanical processing strategy that can be used to process a variety of native and synthetic polymers into highly porous materials composed of nano-scale to micron-scale diameter fibers. By nature, electrospun materials exhibit an extensive surface area and highly interconnected pore spaces. In this study we adopted a biological engineering approach to ask how the specific unique advantages of the electrospinning process might be exploited to produce a new class of research/diagnostic tools. Methods The electrospinning properties of nitrocellulose, charged nylon and blends of these materials are characterized. Results Nitrocellulose electrospun from a starting concentration of < 110 mg/ml acetone deposited as 4–8 μm diameter beads; at 110 mg/ml-to-140 mg/ml starting concentrations, this polymer deposited as 100–4000 nm diameter fibers. Nylon formed fibers when electrospun from 60–140 mg/ml HFIP, fibers ranged from 120 nm-6000 nm in diameter. Electrospun nitrocellulose exhibited superior protein retention and increased sensitivity in slot blot experiments with respect to the parent nitrocellulose material. Western immunoblot experiments using fibronectin as a model protein demonstrated that electrospun nylon exhibits increased protein binding and increased dynamic range in the chemiluminescence detection of antigens than sheets of the parent starting material. Composites of electrospun nitrocellulose and electrospun nylon exhibit high protein binding activity and provide increased sensitivity for the immuno-detection of antigens. Conclusion The flexibility afforded by electrospinning process makes it possible to tailor blotting membranes to specific applications. Electrospinning has a variety of potential applications in the clinical diagnostic field of use. PMID:18271978

  15. Variable stiffness and recruitment using nylon actuators arranged in a pennate configuration

    NASA Astrophysics Data System (ADS)

    Kianzad, Soheil; Pandit, Milind; Lewis, Johnathan D.; Berlingeri, Alexander R.; Haebler, Karl J.; Madden, John D. W.

    2015-04-01

    In muscle variable impedance and ability to recruit fibers as needed helps enable actions such as walking and catching. A new biomimetic structure of nylon actuator is presented that imitates the human pennate muscle in structure, ability to vary stiffness and the ability to increase force by recruiting additional fibers. The actuator consists of 16 silver coated nylon coiled fibers attached to a central tendon at an angle of 20°. Each nylon coil produces 20 MPa of stress at constant length and nearly 20% strain at fixed load. Fibers are individually switched ON and OFF using transistors so that each element can be recruited, and the stiffness varied. The amount of input power is controlled with pulse width modulation (PWM) techniques. It is observed that the spring constant of the pennate structure varies from that of its passive state, 503 N/m and a resonance frequency of 1.4 Hz, to 1480 N/m with resonance frequency of 3.1 Hz in the active state where all the fibers are switched on under a 25 N load. Stiffness can be varied by a factor of 9.

  16. Measuring tropospheric HNO3 - Problems and prospects for Nylon filter and mist chamber techniques

    NASA Technical Reports Server (NTRS)

    Talbot, R. W.; Vijgen, A. S.; Harriss, R. C.

    1990-01-01

    A series of laboratory and field measurements was performed to evaluate the mist chamber technique for determining tropospheric HNO3 concentrations. Both the mist chamber and standard Nylon filter techniques exhibit high collection efficiency and excellent agreement measuring HNO3 vapors from a permeation source. When simultaneously sampling ambient air in eastern Virginia, the Nylon filter measured an average of 70 percent higher HNO3 concentration than the mist chamber technique. The results indicate that O3 causes a low-level positive artifact interference in HNO3 measurements performed with the filter technique. This O3-induced error is small, however, compared to the large difference between atmospheric HNO3 concentrations determined with the two techniques. It is hypothesized that unidentified (organic?) nitrogen species in the atmosphere react for form NO3(-) on the filter and this phenomenon may interfere with Nylon filter measurements of HNO3 vapor. These potential interferences did not appear to affect measurements of HNO3 with the mist chamber method.

  17. Modification of nylon-6 with semi-rigid poly (p-diphenyl oxide terephthalamide)

    SciTech Connect

    Lin, M.F.; Wang, H.H.; Shu, Y.C.

    1994-03-01

    In this study, the flexible nylon-6 was reinforced by the semi-rigid aromatic polyamide, poly (p-diphenyl oxide terephthalamide) (POA), through physical polybending and chemical copolymerization using p-aminophenylacetic acid (P-APA) as a coupling agent. From the DSC measurements, it was shown that Tg of the polyblends was increased with the increase of POA content. The Tg and Tm of multiblock copolyamides were found to be higher than those of polyblends and triblock copolyamides. From the Rheovibron measurements, it was shown that the POA with nylon-6 poy-blends exhibited higher E{prime} and Tg value than that of nylon-6, which increased with the increase of POA content. The Tg and E{prime} values of multiblock copolyamides were higher than those of polyblends triblock copolyamides. Scanning electron microscopy revealed that the polyblends were a dispersed phase structure, although the multiblock copolyamides exhibited a homogeneous texture rather than an aggregated one. From the wide-angle x-ray diffraction pattern, the triblock copolyamides and polyblends had two diffraction peaks, i.e., 2 {theta} = 20.5{degrees} and 24{degrees}. However, the multiblock had only one at 2 {theta} = 20{degrees}, which indicates that a different crystal structure of multiblock copolyamides. For the mechanical properties, it was found that the multiblock copolyamides had a more significant reinforcing effect than those of polyblends and triblock copolyamides. 21 refs., 11 figs., 5 tabs.

  18. Investigation on Dry Sliding Wear Behavior of Nylon66/GnP Nano-composite

    NASA Astrophysics Data System (ADS)

    Sankara Narayana, Kota; Suman, Koka Naga Sai; Arun Vikram, Kothapalli

    2016-06-01

    The tribological behavior of graphene nano platelets (GnP) reinforced Nylon66 polymer Nano composites were studied using a pin-on-disc apparatus under dry sliding conditions. The influence of wear control factors like applied load, velocity, sliding distance and weight percentage of GnP reinforcement on the responses like specific wear rate and frictional coefficient were investigated. Nano composites were developed by melt mixing of various weight fractions of GnP (0/0.5/1/2) with nylon 66 using twin screw extruder. A design of experiments based on the Taguchi technique was performed to acquire data in a controlled way and was successfully used to identify the optimal combinations of control factors influencing the outputs. Analysis of variance was employed to investigate the influence and contribution of control factors on the responses. The results showed that the inclusion of GnP as reinforcing material in Nylon66 Nano composites, decreases the friction coefficient and increases the wear resistance of the Nano composites significantly.

  19. Continuous electrospinning of polymer nanofibers of Nylon-6 using an atomic force microscope tip.

    PubMed

    Gururajan, Giriprasath; Sullivan, S P; Beebe, T P; Chase, D B; Rabolt, J F

    2011-08-01

    An atomic force microscopy (AFM) probe is successfully utilized as an electrospinning tip for fabricating Nylon-6 nanofibers. The nanometre-size tip enabled controlled deposition of uniform polymeric nanofibers within a 1 cm diameter area. Nylon-6 nanofibers were continuously electrospun at a solution concentration as low as 1 wt% Nylon-6 in 1,1,1,3,3,3-hexafluoro-2-propanol (HFIP). Wide-angle X-ray diffraction (WAXD) and differential scanning calorimetry (DSC) results of the AFM electrospun fibers indicated that the nanofibers predominantly display the meta-stable γ crystalline form suggesting rapid crystallization rate during the process. In addition to precise control over fiber deposition and diameter, some of the drawbacks of conventional electrospinning such as large volume of solutions and clogging of needles can be overcome using this AFM based electrospinning technique. Lastly, a comparison of electrospun fibers from syringe-needle based electrospinning and AFM probe-tip based electrospinning indicated significant morphological and microstructural differences in the case of AFM based electrospinning.

  20. Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair

    PubMed Central

    Hennecke, Kathleen; Redeker, Joern; Kuhbier, Joern W.; Strauss, Sarah; Allmeling, Christina; Kasper, Cornelia; Reimers, Kerstin; Vogt, Peter M.

    2013-01-01

    Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials. PMID:23613793

  1. Comparison of a superficial suturing device with a full-thickness suturing device for transoral outlet reduction (with videos)

    PubMed Central

    Kumar, Nitin; Thompson, Christopher C.

    2016-01-01

    Background Larger gastrojejunal (GJ) anastomosis aperture is one independent predictor for weight regain after Roux-en-Y gastric bypass. Transoral outlet reduction (TORe) has proven safe and effective for treatment of weight regain by using a superficial-thickness (ST) suturing device. Full-thickness (FT) suturing devices are now available, potentially providing more effective results. Objective To compare effectiveness of superficial-thickness with full-thickness TORe. Design Matched cohort study: patients were matched sequentially by GJ anastomosis aperture, body mass index, and age. Setting Tertiary-care center. Patients A total of 59 consecutive patients undergoing full-thickness TORe were matched with 59 patients undergoing superficial-thickness TORe. All had GJ anastomosis apertures >20 mm. Intervention Transoral outlet reduction. Main Outcome Measurements Weight loss and rate of adverse events. Results Post-TORe GJ anastomosis apertures were similar between groups (ST 6.9 ± 0.2 mm vs FT 7.1 ± 0.3 mm). Weight loss was greater at 6 months in the FT group (10.6 ± 1.8 kg in FT vs 4.4 ± 0.8 kg in ST; P < .01) and at 1 year (8.6 ± 2.5 kg in FT vs 2.9 ± 1.0 kg in ST; P < .01). Excess weight loss was greater in the FT group at 6 months (20.4 ± 3.3% in FT vs 8.1 ± 2.5% in ST; P < .01) and at 1 year (18.9 ± 5.4% in FT vs 9.1 ± 2.3% in ST; P = .03). Limitations This was a single-center, retrospective, cohort study. Conclusion There is level 1b evidence for effectiveness of TORe by using a superficial mucosal suturing device. This matched cohort study compared TORe by using the same ST suturing device with TORe by using a newer, FT suturing device and the same operative methods. FT TORe resulted in significantly more weight loss than ST TORe at 6 months and at 1 year. Full-thickness TORe is a significant improvement over ST TORe for endoscopic therapy of weight regain in patients with dilated GJ anastomosis. PMID:24721521

  2. Orientation of late Precambrian sutures in the Arabian-Nubian shield

    NASA Technical Reports Server (NTRS)

    Stern, Robert J.; Nielsen, Kent C.; Best, Eric; Sultan, Mohamed; Arvidson, Raymond E.

    1990-01-01

    Recent tectonic models have resulted in conflicting descriptions of how the late Precambrian sutures of the Arabian-Nubian shield extend into northeast Africa. The Hamisana shear zone in northeastern Sudan is critical to this discussion because it truncates and disrupts two sutures, the Allaqi-Heiani and the Onib-Sol Hamed. Analysis of field structural data, Thematic Mapper imagery, and Rb-Sr and U-Pb geochronology suggests that the Allaqi-Heiani suture is the western extension of the Onib-Sol Hamed suture and that both make up the exposed parts of a far-traveled, polydeformed ophiolitic nappe complex. Subsequent deformation localized in the Hamisana shear zone disrupted this nappe and displaced the suture between 660 and 550 Ma during regional deformation associated with the Najd fault system. These results indicate that at least one suture extends westward into the interior of northern Africa.

  3. [Morphological changes of tissues in formation of a welding suture on the large intestine].

    PubMed

    Bondar', G V; Basheev, V Kh; Borota, A V; Miroshnichenko, E Iu; Koshik, E A

    2011-01-01

    Abdominoanal resection with descending of left colon on perineum, leaving additional part of a descended intestine, was performed. For the hemorrhage arrest the welding sutures were put on intestinal wall. According to morphological investigations data, a damage of intestinal wall in the zone of a welding suture application is a reversible one, it spreads from the electrode branch on 2-3 mm. The presence of undamaged structures witnesses the presence of an active regeneration process in tissues around the welding suture.

  4. A new, removable, sliding noose for adjustable-suture strabismus surgery.

    PubMed

    Deschler, Emily K; Irsch, Kristina; Guyton, Kristina L; Guyton, David L

    2013-10-01

    We describe a new removable sliding polyglactin 910 suture noose for postoperative suture adjustment following extraocular muscle surgery. No excess suture material remains after adjustment has been completed, helping to reduce discomfort, inflammation, and scarring. We have used this noose with the cul-de-sac conjunctival incision in approximately 360 patients over a period of 18 months. This report details how to fashion, use, and remove the noose.

  5. Gene Expression Changes Between Patent and Fused Cranial Sutures in a Nonsyndromic Craniosynostosis Population

    PubMed Central

    Rhodes, Jennifer L.; Vega, Rafael A.; Ridder, Thomas; Shiang, Rita

    2015-01-01

    Objective: Craniosynostosis is a premature fusion of 1 or more cranial sutures. It may occur with additional morphological abnormalities (syndromic) or in isolation. Studies suggest that dysregulation of normal cell proliferation, differentiation, and migration has a role in isolated or nonsyndromic craniosynostosis but the molecular mechanisms remain unknown. The aim of this research is to identify genes differentially expressed in prematurely fused human suture compared to patent suture in nonsyndromic craniosynostosis. Methods: Bone fragments from synostosed and patent sutures of 7 infants with nonsyndromic craniosynostosis were collected during surgical release of fused sutures. RNA was isolated from the fragments (7 patent and 7 fused) and global gene expression profiled using the Illumina WGE-DASL assay and HumanRef 8.0 Beadchip. Results: Comparison of mRNA expression in fused and patent suture identified 68 genes significantly differentially expressed and having fold changes ≤ −2.0 and ≥ 2.0 with a false discovery rate adjusted P value at .10 and 136 with adjusted P value of 0.15. SFRP2 (secreted frizzled-related protein 2) demonstrated the largest decrease in fused sutures. Analysis including only sagittal fused sutures revealed a set of 35 overlapping genes that may be involved in suture patency over all suture types. SPHKAP (sphingosine kinase type 1-interacting protein), a modulator of TGFβ signaling, was significant in the sagittal subset. Conclusion: Differentially expressed genes were identified in fused suture relative to patent in a nonsyndromic craniosynostosis population. SFRP2 is likely important in suture patency. Genes having significant roles in osteoblastogenesis as negative regulators of canonical Wnt pathway were significantly downregulated. PMID:25987937

  6. Sequential lift and suture technique for post-LASIK corneal striae.

    PubMed

    Mackool, Richard J; Monsanto, Vivian R

    2003-04-01

    We describe a surgical technique to manage persistent corneal striae after laser in situ keratomileusis (LASIK). The sequential lift and suture technique reduces the time required for LASIK, eliminates the need to fixate the flap with forceps during suturing, and increases the accuracy of suture placement. The results in 10 eyes (9 patients) showed complete resolution of striae with improvement in subjective symptoms (glare and blurred vision) and best corrected visual acuity.

  7. Clinical Outcomes After Suture Anchor Repair of Recalcitrant Medial Epicondylitis.

    PubMed

    Grawe, Brian M; Fabricant, Peter D; Chin, Christopher S; Allen, Answorth A; DePalma, Brian J; Dines, David M; Altchek, David W; Dines, Joshua S

    2016-01-01

    This study evaluated clinical and patient-reported outcomes and return to sport after surgical treatment of medial epicondylitis with suture anchor fixation. Consecutive patients were evaluated after undergoing debridement and suture anchor repair of the flexor-pronator mass for the treatment of medial epicondylitis. Demographic variables, a short version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH) score, Oxford Elbow Score (OES), and 10-point pain and satisfaction scales were collected. Ability and time to return to sport after surgery were evaluated, and the relationship between predictor variables and both elbow function and return to sport was investigated. Median age at the time of surgery was 55 years (range, 29-65 years), with median follow-up of 40 months (range, 12-67 months). Median QuickDASH score and OES at final follow-up were 2.3 (range, 0-38.6) and 45 (range, 22-48), respectively. Most patients returned to premorbid sporting activities at a median of 4.5 months (range, 2.5-12 months), whereas 4 patients (14%) reported significant limitations at final follow-up. Older age at the time of surgery was predictive of better QuickDASH score and OES (P=.05 and P=.02, respectively). Patients who underwent surgery after a shorter duration of symptoms had better outcomes, but the difference did not reach statistical significance (QuickDASH, P=.09; OES, P=.10). Surgical treatment of recalcitrant medial epicondylitis with suture anchor fixation offers good pain relief and patient satisfaction, with little residual disability. Older age at the time of surgery predicts a better outcome.

  8. Clinical Results of Meniscal Repair Using Submeniscal Horizontal Sutures

    PubMed Central

    Navali, Amir Mohammad; Aslani, Hossein

    2015-01-01

    Background: Parts of the implants placed over the meniscus during meniscal repair can wear down the cartilage in the contact zones and cause chronic synovitis. Placing horizontal sutures under the meniscus may overcome this potential hazard. The purpose of this prospective study was to evaluate the midterm results of arthroscopic meniscal repair using submeniscally placed out-in horizontal sutures. Methods: One hundred and three meniscal repairs with submeniscal horizontal out-in technique in 103 patients were performed between 2009 and 2012. Our indications for meniscal repair were all longitudinal tear in red-red and red-white zone with acceptable tissue quality. Clinical evaluation included the Tegner and Lysholm knee scores and clinical success was defined as absence of joint-line tenderness, locking, swelling, and a negative McMurray test. Results: The average follow-up was 19 months (range, 14 to 40 months). The time interval from injury to meniscal repair ranged from 2 days to 390 days (median, 96 days). At the end of follow-up, the clinical success rate was 86.5%. Fourteen of 103 repaired menisci (13.5%) were considered failures according to Barrett’s criteria. The mean Lysholm score significantly improved from 39.6 preoperatively to 84.5 postoperatively (P<0.001). Eighty five patients (82.5%) had an excellent or good result according to Lysholm knee score. Tegner activity score improved significantly (P<0.01) from an average of 3.4 (range, 2-6) preoperatively to 5.9 (range, 5-8) postoperatively. Statistical analysis showed that age, simultaneous anterior cruciate ligament reconstruction, chronicity of injury did not affect the clinical outcome. Conclusion: Our results showed that acceptable midterm results are expected from submeniscal horizontal out-in repair technique. This technique is cheap, safe and has the advantage of avoiding chondral abrasion caused by solid implants and suture materials placed over the meniscus. PMID:26213701

  9. Effects of suture position on left ventricular fluid mechanics under mitral valve edge-to-edge repair.

    PubMed

    Du, Dongxing; Jiang, Song; Wang, Ze; Hu, Yingying; He, Zhaoming

    2014-01-01

    Mitral valve (MV) edge-to-edge repair (ETER) is a surgical procedure for the correction of mitral valve regurgitation by suturing the free edge of the leaflets. The leaflets are often sutured at three different positions: central, lateral and commissural portions. To study the effects of position of suture on left ventricular (LV) fluid mechanics under mitral valve ETER, a parametric model of MV-LV system during diastole was developed. The distribution and development of vortex and atrio-ventricular pressure under different suture position were investigated. Results show that the MV sutured at central and lateral in ETER creates two vortex rings around two jets, compared with single vortex ring around one jet of the MV sutured at commissure. Smaller total orifices lead to a higher pressure difference across the atrio-ventricular leaflets in diastole. The central suture generates smaller wall shear stresses than the lateral suture, while the commissural suture generated the minimum wall shear stresses in ETER.

  10. Patterns and implications of extensive heterochrony in carnivoran cranial suture closure.

    PubMed

    Goswami, A; Foley, L; Weisbecker, V

    2013-06-01

    Heterochronic changes in the rate or timing of development underpin many evolutionary transformations. In particular, the onset and rate of bone development have been the focus of many studies across large clades. In contrast, the termination of bone growth, as estimated by suture closure, has been studied far less frequently, although a few recent studies have shown this to represent a variable, although poorly understood, aspect of developmental evolution. Here, we examine suture closure patterns across 25 species of carnivoran mammals, ranging from social-insectivores to hypercarnivores, to assess variation in suture closure across taxa, identify heterochronic shifts in a phylogenetic framework and elucidate the relationship between suture closure timing and ecology. Our results show that heterochronic shifts in suture closure are widespread across Carnivora, with several shifts identified for most major clades. Carnivorans differ from patterns identified for other mammalian clades in showing high variability of palatal suture closure, no correlation between size and level of suture closure, and little phylogenetic signal outside of musteloids. Results further suggest a strong influence of feeding ecology on suture closure pattern. Most of the species with high numbers of heterochronic shifts, such as the walrus and the aardwolf, feed on invertebrates, and these taxa also showed high frequency of closure of the mandibular symphysis, a state that is relatively rare among mammals. Overall, caniforms displayed more heterochronic shifts than feliforms, suggesting that evolutionary changes in suture closure may reflect the lower diversity of cranial morphology in feliforms. PMID:23530892

  11. Electrospun Polymeric Core-sheath Yarns as Drug Eluting Surgical Sutures.

    PubMed

    Padmakumar, Smrithi; Joseph, John; Neppalli, Madhuri Harsha; Mathew, Sumi Elizabeth; Nair, Shantikumar V; Shankarappa, Sahadev A; Menon, Deepthy

    2016-03-23

    Drug-coated sutures are widely used as delivery depots for antibiotics and anti-inflammatory drugs at surgical wound sites. Although drug-laden coating provides good localized drug concentration, variable loading efficiency and release kinetics limits its use. Alternatively, drug incorporation within suture matrices is hampered by the harsh fabrication conditions required for suture-strength enhancement. To circumvent these limitations, we fabricated mechanically robust electrospun core-sheath yarns as sutures, with a central poly-l-lactic acid core, and a drug-eluting poly-lactic-co-glycolic acid sheath. The electrospun sheath was incorporated with aceclofenac or insulin to demonstrate versatility of the suture in loading both chemical and biological class of drugs. Aceclofenac and insulin incorporated sutures exhibited 15% and 4% loading, and release for 10 and 7 days, respectively. Aceclofenac sutures demonstrated reduced epidermal hyperplasia and cellularity in skin-inflammation animal model, while insulin loaded sutures showed enhanced cellular migration in wound healing assay. In conclusion, we demonstrate an innovative strategy of producing mechanically strong, prolonged drug-release sutures loaded with different classes of drugs. PMID:26936629

  12. Differential spatial regulation of BMP molecules is associated with single-suture craniosynostosis.

    PubMed

    Whitton, Alaina; Hyzy, Sharon L; Britt, Chelsea; Williams, Joseph K; Boyan, Barbara D; Olivares-Navarrete, Rene

    2016-07-01

    OBJECTIVE The aim of this study was to examine messenger RNA (mRNA) levels of bone morphogenetic protein (BMP) ligands, receptors, and soluble inhibitors in cells isolated from single-suture synostoses from fused coronal, metopic, sagittal, and lambdoid sutures. METHODS Cells were isolated from bone collected from patients undergoing craniotomies at Children's Healthcare of Atlanta. Real-time polymerase chain reaction was used to examine mRNA levels in cells isolated from fused sutures or patent sutures in comparison with levels in normal bone from the same patient. RESULTS Cells isolated from fused sutures in cases of sagittal and coronal synostosis highly expressed BMP2, while cells isolated from fused metopic or lambdoid synostosis expressed high BMP4. Noggin, a BMP inhibitor, was lower in fused sutures and had high expression in patent sutures. CONCLUSIONS These results suggest that BMPs and inhibitors play a significant role in the regulation of suture fusion as well in the maintenance of patency in the normal suture. PMID:27035551

  13. Suture anchor repair of quadriceps tendon rupture after total knee arthroplasty.

    PubMed

    Kim, Tae Won B; Kamath, Atul F; Israelite, Craig L

    2011-08-01

    Disruption of the extensor mechanism after total knee arthroplasty (TKA) is a devastating complication, usually requiring surgical repair. Although suture anchor fixation is well described for repair of the ruptured native knee quadriceps tendon, no study has discussed the use of suture anchors in quadriceps repair after TKA. We present an illustrative case of successful suture anchor fixation of the quadriceps mechanism after TKA. The procedure has been performed in a total of 3 patients. A surgical technique and brief review of the literature follows. Suture anchor fixation of the quadriceps tendon is a viable option in the setting of rupture after TKA.

  14. Patterns and implications of extensive heterochrony in carnivoran cranial suture closure

    PubMed Central

    Goswami, A; Foley, L; Weisbecker, V

    2013-01-01

    Heterochronic changes in the rate or timing of development underpin many evolutionary transformations. In particular, the onset and rate of bone development have been the focus of many studies across large clades. In contrast, the termination of bone growth, as estimated by suture closure, has been studied far less frequently, although a few recent studies have shown this to represent a variable, although poorly understood, aspect of developmental evolution. Here, we examine suture closure patterns across 25 species of carnivoran mammals, ranging from social-insectivores to hypercarnivores, to assess variation in suture closure across taxa, identify heterochronic shifts in a phylogenetic framework and elucidate the relationship between suture closure timing and ecology. Our results show that heterochronic shifts in suture closure are widespread across Carnivora, with several shifts identified for most major clades. Carnivorans differ from patterns identified for other mammalian clades in showing high variability of palatal suture closure, no correlation between size and level of suture closure, and little phylogenetic signal outside of musteloids. Results further suggest a strong influence of feeding ecology on suture closure pattern. Most of the species with high numbers of heterochronic shifts, such as the walrus and the aardwolf, feed on invertebrates, and these taxa also showed high frequency of closure of the mandibular symphysis, a state that is relatively rare among mammals. Overall, caniforms displayed more heterochronic shifts than feliforms, suggesting that evolutionary changes in suture closure may reflect the lower diversity of cranial morphology in feliforms. PMID:23530892

  15. Timing of ectocranial suture activity in Pan troglodytes as related to cranial volume and dental eruption.

    PubMed

    Cray, James; Mooney, Mark P; Siegel, Michael I

    2010-08-01

    Research has shown that Pan and Homo have similar ectocranial suture synostosis patterns possibly because of their phylogenetic relationship. However, unlike human data, it is unclear if the ontogeny of suture activity for Pan exhibits a relationship with the expanding neurocranium or the masticatory apparatus. These relationships were assessed by examining the associations between ectocranial suture status and morphology and cranial volume (as a proxy for neurocranial expansion) and dental development (as an indicator of adulthood and proxy for masticatory influence) in a large sample of Pan troglodytes skulls. One hundred and fifty-five P. troglodytes dry skulls were examined, and data were collected on ectocranial suture closure status, cranial volume, and dental eruption status. Regression models were calculated for suture status by cranial volumes, and Kendall's tau (a nonparametric measure of association) was calculated for suture status by dental eruption status. Results suggest that suture synostosis activity in P. troglodytes exhibits a period of stasis after neurocranial expansion cessation and does not have a strong relationship with brain development (r(2) ranged from 0.09 to 0.28), as similarly seen in Homo. Instead, suture synostosis has a stronger relationship with dental development (tau ranged from 0.59 to 0.72), where most osseous activity occurs after full adult dental eruption. This suggests that masticatory forces may influence both ectocranial suture morphology and synostosis more than brain expansion does in Pan, as also similarly noted in Homo.

  16. Recent advances in biodegradable metals for medical sutures: a critical review.

    PubMed

    Seitz, Jan-Marten; Durisin, Martin; Goldman, Jeremy; Drelich, Jaroslaw W

    2015-09-16

    Sutures that biodegrade and dissolve over a period of several weeks are in great demand to stitch wounds and surgical incisions. These new materials are receiving increased acceptance across surgical procedures whenever permanent sutures and long-term care are not needed. Unfortunately, both inflammatory responses and adverse local tissue reactions in the close-to-stitching environment are often reported for biodegradable polymeric sutures currently used by the medical community. While bioabsorbable metals are predominantly investigated and tested for vascular stent or osteosynthesis applications, they also appear to possess adequate bio-compatibility, mechanical properties, and corrosion stability to replace biodegradable polymeric sutures. In this Review, biodegradable alloys made of iron, magnesium, and zinc are critically evaluated as potential materials for the manufacturing of soft and hard tissue sutures. In the case of soft tissue closing and stitching, these metals have to compete against currently available degradable polymers. In the case of hard tissue closing and stitching, biodegradable sternal wires could replace the permanent sutures made of stainless steel or titanium alloys. This Review discusses the specific materials and degradation properties required by all suture materials, summarizes current suture testing protocols and provides a well-grounded direction for the potential future development of biodegradable metal based sutures.

  17. Elimination of stick-slip of elastomeric sutures by radiofrequency glow discharge deposited coatings.

    PubMed

    Griesser, H J; Chatelier, R C; Martin, C; Vasic, Z R; Gengenbach, T R; Jessup, G

    2000-01-01

    Fine elastomeric sutures intended for cardiovascular surgery can exhibit "stick-slip" behavior as they are pulled through tissue; the resulting oscillatory force can damage delicate tissue or cause sutures to snap. To eliminate this undesirable effect, sutures were surface-modified using a radiofrequency glow discharge in a vapor of either hexamethyldisiloxane or hexamethyldisilazane, to produce a thin polymeric coating on the suture. The same coatings were also deposited onto aluminized tape to facilitate their characterization by measurement of air/water contact angles and by X-ray photoelectron spectroscopy. Coatings from both monomers were found to be very hydrophobic. The hexamethyldisiloxane glow discharge coatings underwent negligible oxidation when stored in air, and thus remained stable over a shelf-life period akin to what may be required of sutures. The hexamethyldisilazane glow discharge coatings, in contrast, incorporated substantial amounts of oxygen over a 3-month period. The coatings did not measurably alter the tensile properties of the sutures. The frictional properties of coated sutures were assessed by measuring the dynamic friction between the suture and ovine myocardium. Both coatings were effective in removing the inherent stick-slip behavior of polybutester sutures in this model. The coatings remained intact after several passes and proved to be robust and efficacious under various strain regimes. PMID:10813763

  18. Modified technique of stapled esophagojejunostomy without a purse-string suture.

    PubMed

    Seshadri, Ramakrishnan Ayloor; Thammaiah, Siddappa K; Vaidhyalingam, Venktesh

    2011-09-01

    Placement of a purse-string suture during a stapled esophagojejunostomy following total gastrectomy is a technically demanding and time consuming procedure. Improper placement of the purse-string suture can lead to anastamotic breakdown with its associated complications. We describe a technique of stapled esophagojejunostomy without using a purse-string suture. We used this technique in 35 patients including 4 patients who underwent an extended total gastrectomy. We encountered a difficulty only in one patient due to malfunction of the stapler. None of the patients had an anastamotic leak. The modified technique of stapled esophagojejunostomy without a purse-string suture makes the procedure more easy, safe and simple.

  19. Description of a novel technique for suture ligation of the renal vessels during robotic nephrectomy.

    PubMed

    Patel, Manish N; Laungani, Rajesh; Shrivastava, Alok; Bhandari, Akshay; Spencer Krane, L; Menon, Mani; Rogers, Craig G

    2009-03-01

    Minimally invasive techniques are frequently used for surgical treatment of suspected malignant renal masses. We previously reported on our experience with robotic nephrectomy and the feasibility of performing suture ligation of the renal vessels using robotic needle drivers. We describe a novel technique for suture ligation of the renal vessels during robotic nephrectomy utilizing the robotic hook and a suture with loops at each end. Our technique for suture ligation of the renal vessels recapitulates the open technique without the need for exchanging the robotic working instruments for robotic needle drivers and without the need for endovascular staplers. PMID:27628449

  20. Preparation and properties of banana fiber-reinforced composites based on high density polyethylene (HDPE)/Nylon-6 blends.

    PubMed

    Liu, H; Wu, Q; Zhang, Q

    2009-12-01

    Banana fiber (BaF)-filled composites based on high density polyethylene (HDPE)/Nylon-6 blends were prepared via a two-step extrusion method. Maleic anhydride grafted styrene/ethylene-butylene/styrene triblock polymer (SEBS-g-MA) and maleic anhydride grafted polyethylene (PE-g-MA) were used to enhance impact performance and interfacial bonding between BaF and the resins. Mechanical, crystallization/melting, thermal stability, water absorption, and morphological properties of the composites were investigated. In the presence of SEBS-g-MA, better strengths and moduli were found for HDPE/Nylon-6 based composites compared with corresponding HDPE based composites. At a fixed weight ratio of PE-g-MA to BaF, an increase of BaF loading up to 48.2 wt.% led to a continuous improvement in moduli and flexural strength of final composites, while impact toughness was lowered gradually. Predicted tensile modulus by the Hones-Paul model for three-dimensional random fiber orientation agreed well with experimental data at the BaF loading of 29.3 wt.%. However, the randomly-oriented fiber models underestimated experimental data at higher fiber levels. It was found that the presence of SEBS-g-MA had a positive influence on reinforcing effect of the Nylon-6 component in the composites. Thermal analysis results showed that fractionated crystallization of the Nylon-6 component in the composites was induced by the addition of both SEBS-g-MA and PE-g-MA. Thermal stability of both composite systems differed slightly, except an additional decomposition peak related to the minor Nylon-6 for the composites from the HDPE/Nylon-6 blends. In the presence of SEBS-g-MA, the addition of Nylon-6 and increased BaF loading level led to an increase in the water absorption value of the composites.

  1. A new technique to improve the mechanical and biological performance of ultra high molecular weight polyethylene using a nylon coating.

    PubMed

    Firouzi, Dariush; Youssef, Aya; Amer, Momen; Srouji, Rami; Amleh, Asma; Foucher, Daniel A; Bougherara, Habiba

    2014-04-01

    A new patent pending technique is proposed in this study to improve the mechanical and biological performance of ultra high molecular weight polyethylene (UHMWPE), i.e., to uniformly coat nylon onto the UHMWPE fiber (Firouzi et al., 2012). Mechanical tests were performed on neat and new nylon coated UHMWPE fibers to examine the tensile strength and creep resistance of the samples at different temperatures. Cytotoxicity and osteolysis induced by wear debris of the materials were investigated using (MTT) assay, and RT-PCR for tumor necrosis factor alpha (TNFα) and interleukin 6 (IL-6) osteolysis markers. Mechanical test results showed substantial improvement in maximum creep time, maximum breaking force, and toughness values of Nylon 6,6 and Nylon 6,12 coated UHMWPE fibers between average 15% and 60% at 25, 50, and 70°C. Furthermore, cytotoxicity studies have demonstrated significant improvement in cell viability using the nylon coated UHMWPE over the neat one (72.4% vs 54.8%) for 48h and (80.7 vs 5%) for 72h (P<0.01). Osteolysis test results have shown that the expression levels of TNFα and IL-6 markers induced by the neat UHMWPE fiber were significantly higher than those induced by the Nylon 6,6 coated UHMWPE (2.5 fold increase for TNFα at 48h, and three fold increase for IL-6 at 72h (P<0.01)). This study suggests that UHMWPE coated with nylon could be used as a novel material in clinical applications with lower cytotoxicity, less wear debris-induced osteolysis, and superior mechanical properties compared to neat UHMWPE.

  2. The preparation of nylon-tube-supported hexokinase and glucose 6-phosphate dehydrogenase and the use of the co-immobilized enzymes in the automated determination of glucose.

    PubMed Central

    Morris, D L; Campbell, J; Hornby, W E

    1975-01-01

    Triethyloxonium tetrafluoroborate was used to O-alkylate nylon-tube thus producing the imidate salt of the nylon which was further made to react with 1,6-diaminohexane. 2. Hexokinase (EC 2.7.1.1) and glucose 6-phosphate dehydrogenase (EC 1.1.1.49) were immobilized on the amino-substituted nylon tube through glutaraldeyde and bisimidates. 3. The effect of varying the conditions of O-alkylation and the amount of enzyme immobilized on the activity of nylon tube-hexokinase derivatives was determined. 4. The effect of varying the amount of enzyme immobilized on the activity of nylon-tube-glucose 6-phosphate dehydrogenase derivatives was determined. 5. The thermal stability of nylon-tube-hexokinase and nylon-tube-glucose 6-phosphate dehydrogenase derivatives was studied. 6. Different ratios of hexokinase and glucose 6-phosphate dehydrogenase were co-immobilized on nylon tube, and the rate of conversion of glucose into 6-phosphogluconolactone was compared with the individual activities of the immobilized enzymes. 7. Hexokinase and glucose 6-phosphate dehydrogenase co-immobilized on nylon tube were used in the automated analysis of glucose. PMID:1167161

  3. Barbed Suture as a Treatment Approach in Complex Degloving Injuries.

    PubMed

    Boudreault, David Jean-Guy; Lance, Sam H; Garcia, Jesus A

    2016-05-01

    In the late 19th century, French physician Morel-Lavallée was challenged with a group of patients who sustained similar patterns of degloving injuries, which today carry his eponym. In 1853, he reported a series of cases as well as proposed strategies for the management of these complex degloving injuries. Treatment strategies have not varied significantly over the years, and these lesions continue to plague surgeons today with failure rates in excess of 50%. We present 2 case series using barbed suture in the management of these complex injuries. PMID:26954732

  4. Iris mattress suture: a technique for sectoral iris defect repair.

    PubMed

    Tsao, Sean W; Holz, Huck A

    2015-03-01

    Achieving a cosmetic and functional outcome from iris defect repair is a surgical challenge. We describe an adaptation of techniques to address a case of 2.5 clock hours of sectoral iris tissue defect. Our method combines Siepser's modified closed-chamber sliding knot technique with the placement of a double-armed iris mattress suture to approximate iris tissue to the scleral wall and thereby create a pseudo-iris root. This technique reduces glare and achieves a cosmetic outcome for the patient.

  5. Outcome of repair of chronic tear of the pectoralis major using corkscrew suture anchors by box suture sliding technique

    PubMed Central

    Joshi, Deepak; Jain, Jitesh Kumar; Chaudhary, Deepak; Singh, Utkarsh; Jain, Vineet; Lal, Ajay

    2016-01-01

    AIM To assess the functional and clinical results of repair of chronic tears of pectoralis major using corkscrew and sliding suture technique. METHODS In this retrospective study, we reviewed the results of pectoralis major repair in 11 chronic cases (> 6 wk) done between September 2011 and December 2014 at our institute. In all cases repair was done by same surgeon using corkscrew suture anchors and box suture sliding technique. At 6 mo, after surgery magnetic resonance imaging was done to see the integrity of the repair. Functional evaluation was done using Penn and ASES scores. Pre and postoperative Isokinetic strength was measured. RESULTS Average follow-up was 48.27 ± 21.0 mo. The Wilcoxon signed rank test was used to evaluate the outcome scores. The average ASES score increased from an average of 54.63 ± 13.0 preoperatively to 95.09 ± 2.60 after surgery at their last follow-up. The average Penn score also increased from 5.72 ± 0.78, 2.81 ± 1.32 and 45.81 ± 1.72 to 9.36 ± 0.80, 8.27 ± 0.90 and 59 ± 1.34 for pain, satisfaction and function respectively. Follow up magnetic resonance imaging (MRI) (at 6 mo) showed continuity and the bulk of pectoralis major muscle in all cases. Average isokinetic strength deficiency in horizontal adduction at 60° was 13.63% ± 6.93% and at 120° was 10.18% ± 4.93% and in flexion at 60° was 10.72% ± 5.08% and at 120° was 6.63% + 3.74%. Results showed that both ASES and Penn score improved significantly (2 tailed P value = 0.0036). CONCLUSION We could conclude from this series that pectoralis major repair even in chronic cases using 5.5 mm corkscrew anchors give excellent functional and cosmetic results. In chronic cases the repairable length of the tendon is not available and sliding suture technique allows for fixation of worn out tendomuscular junction to bone without letting cutting through the muscle. PMID:27795949

  6. Suture of a stab wound of the heart.

    PubMed

    Ellis, Harold

    2015-01-01

    Over many centuries, from the early writings of Galen, 'the father of Medicine', wounds of the heart were considered fatal and outside the remit of surgery. With the advent of anaesthesia, (ether was introduced by William Morton in 1846) and of antiseptic surgery, (Joseph Lister's first publication was in 1867), there was an explosion in the surgery of the abdominal cavity, the chest, the skull and the limbs, yet the heart was considered by the surgical fraternity to be the 'no-go' area of the body. Theodor Billroth, Professor of Surgery in Vienna and himself a pioneer of modern surgery, (he performed the first successful partial gastrectomy for carcinoma of the stomach in 1881), wrote "the surgeon who would attempt to suture a wound of the heart should lose the respect of his colleagues". In London, Stephen Paget, in 1896, wrote: "No new method and no new discovery can overcome the natural difficulties that attend a wound of the heart. It is true that suture has been vaguely proposed as a possible procedure and has been done in animals but I cannot find that it has ever been attempted in practice". (In fact, the heart is an amazingly tough and efficient pump that goes on working, year after year, without ever stopping for a service!). PMID:26309960

  7. Suture of new and old peripheral meniscus tears.

    PubMed

    Hamberg, P; Gillquist, J; Lysholm, J

    1983-02-01

    A prospective study of repaired vertical peripheral tears of the meniscus in fifty patients (nine women and forty-one men) was carried out from January 1977 to June 1980. All tears were confirmed preoperatively by arthroscopy. Forty-three medial and seven lateral menisci were repaired. Fifteen tears were treated within two weeks and thirty-five were operated on as long as seven years after injury. Only eight patients had a meniscal tear that was not accompanied by injuries of either the anterior cruciate ligament or the collateral ligaments, or both. At a mean follow-up of eighteen months (range, six to thirty-nine months), forty-two patients (84 per cent) had clinically apparent healing of the sutured meniscal tear. Repeat arthroscopy was done in twenty-seven (64 per cent) of these patients, four to twenty-nine months (mean, twelve months) after the operation. The arthroscopy proved that all of these repaired tears had healed. Eight patients had a second tear after the initial repair: four were reruptures at the sutured area and four were new ruptures in another area of the meniscus and were associated with fresh trauma. All of these patients subsequently had an arthroscopic meniscectomy.

  8. Stapler suture of the pharynx after total laryngectomy.

    PubMed

    Dedivitis, R A; Aires, F T; Pfuetzenreiter, E G; Castro, M A F; Guimarães, A V

    2014-04-01

    The use of a stapler for pharyngeal closure during total laryngectomy was first described in 1971. It provides rapid watertight closure without surgical field contamination. The objective of our study was to compare the incidence of pharyngocutaneous fistula after total laryngectomy with manual and mechanical closures of the pharynx. This was a non-randomised, prospective clinical study conducted at two tertiary medical centres from 1996 to 2011 including consecutive patients with laryngeal tumours who underwent total laryngectomy. We compared the incidence of pharyngocutaneous fistula between two groups of patients: in 20 patients, 75 mm linear stapler closure was applied, whereas in 67 patients a manual suture was used. Clinical data were compared between groups. The groups were statistically similar in terms of gender, age, diabetes mellitus, smoking and alcohol consumption and tumour site. The group of patients who underwent stapler-assisted pharyngeal closure had a higher number of patients with previous tracheotomy (p < 0.001) and previous chemoradiation (p < 0.001). The incidence of pharyngocutaneous fistula was 30% in the mechanical closure group and 20.9% in the manual suture group (p = 0.42). In conclusion the use of the stapler does not increase the rate of fistulae.

  9. Modified arthroscopic suture fixation of a displaced tibial eminence fracture.

    PubMed

    Lehman, Ronald A; Murphy, Kevin P; Machen, M Shaun; Kuklo, Timothy R

    2003-02-01

    This study describes a new arthroscopic method using a whip-stitch technique for treating a displaced type III tibial eminence fracture. A 12-year-old girl who sustained a displaced type III tibial eminence fracture was treated with arthroscopic fixation using the Arthrosew disposable suture device (Surgical Dynamics, Norwalk, CT) to place a whip stitch into the anterior cruciate ligament (ACL). The Arthrex ACL guide (Arthrex, Naples, FL) was used to reduce the avulsed tibial spine fragment. Sutures were then passed through the tibial tunnel and secured over a bony bridge with the knee in 20 degrees of flexion. At 9 months, the patient has a full range of motion with normal Lachman and anterior drawer testing, and she has returned to competitive basketball. Radiographs show complete fracture healing. KT-1000 and isokinetic testing at 9-month follow-up show only minimal side-to-side differences. The Arthrosew device provides a significant advantage in the treatment of type III and IV fractures of the tibial eminence by obtaining arthroscopic fixation within the substance of the ACL, thus obviating arthrotomy and hardware placement. This technique also restores the proper length and tension to the ACL, and provides a simplified, reproducible method of treatment for this injury.

  10. Antibacterial Surgical Silk Sutures Using a High-Performance Slow-Release Carrier Coating System.

    PubMed

    Chen, Xiaojie; Hou, Dandan; Wang, Lu; Zhang, Qian; Zou, Jiahan; Sun, Gang

    2015-10-14

    Sutures are a vital part for surgical operation, and suture-associated surgical site infections are an important issue of postoperative care. Antibacterial sutures have been proved to reduce challenging complications caused by bacterial infections. In recent decades, triclosan-free sutures have been on their way to commercialization. Alternative antibacterial substances are becoming relevant to processing surgical suture materials. Most of the antibacterial substances are loaded directly on sutures by dipping or coating methods. The aim of this study was to optimize novel antibacterial braided silk sutures based on levofloxacin hydrochloride and poly(ε-caprolactone) by two different processing sequences, to achieve suture materials with slow-release antibacterial efficacy and ideal physical and handling properties. Silk strands were processed into sutures on a circular braiding machine, and antibacterial treatment was introduced alternatively before or after braiding by two-dipping-two-rolling method (M1 group and M2 group). The antibacterial activity and durability against Staphylococcus aureus and Escherichia coli were tested. Drug release profiles were measured in phosphate buffer with different pH values, and release kinetics model was built to analyze the sustained drug release mechanism between the interface of biomaterials and the in vitro aqueous environment. Knot-pull tensile strength, thread-to-thread friction, and bending stiffness were determined to evaluate physical and handling properties of sutures. All coated sutures showed continuous antibacterial efficacy and slow drug release features for more than 5 days. Besides, treated sutures fulfilled U.S. Pharmacopoeia required knot-pull tensile strength. The thread-to-thread friction and bending stiffness for the M1 group changed slightly when compared with those of uncoated ones. However, physical and handling characteristics of the M2 group tend to approach those of monofilament ones. The novel suture

  11. Antibacterial Surgical Silk Sutures Using a High-Performance Slow-Release Carrier Coating System.

    PubMed

    Chen, Xiaojie; Hou, Dandan; Wang, Lu; Zhang, Qian; Zou, Jiahan; Sun, Gang

    2015-10-14

    Sutures are a vital part for surgical operation, and suture-associated surgical site infections are an important issue of postoperative care. Antibacterial sutures have been proved to reduce challenging complications caused by bacterial infections. In recent decades, triclosan-free sutures have been on their way to commercialization. Alternative antibacterial substances are becoming relevant to processing surgical suture materials. Most of the antibacterial substances are loaded directly on sutures by dipping or coating methods. The aim of this study was to optimize novel antibacterial braided silk sutures based on levofloxacin hydrochloride and poly(ε-caprolactone) by two different processing sequences, to achieve suture materials with slow-release antibacterial efficacy and ideal physical and handling properties. Silk strands were processed into sutures on a circular braiding machine, and antibacterial treatment was introduced alternatively before or after braiding by two-dipping-two-rolling method (M1 group and M2 group). The antibacterial activity and durability against Staphylococcus aureus and Escherichia coli were tested. Drug release profiles were measured in phosphate buffer with different pH values, and release kinetics model was built to analyze the sustained drug release mechanism between the interface of biomaterials and the in vitro aqueous environment. Knot-pull tensile strength, thread-to-thread friction, and bending stiffness were determined to evaluate physical and handling properties of sutures. All coated sutures showed continuous antibacterial efficacy and slow drug release features for more than 5 days. Besides, treated sutures fulfilled U.S. Pharmacopoeia required knot-pull tensile strength. The thread-to-thread friction and bending stiffness for the M1 group changed slightly when compared with those of uncoated ones. However, physical and handling characteristics of the M2 group tend to approach those of monofilament ones. The novel suture

  12. New insights into the relationship between suture closure and craniofacial dysmorphology in sagittal nonsyndromic craniosynostosis

    PubMed Central

    Heuzé, Yann; Boyadjiev, Simeon A; Marsh, Jeffrey L; Kane, Alex A; Cherkez, Elijah; Boggan, James E; Richtsmeier, Joan T

    2010-01-01

    Premature closure of the sagittal suture occurs as an isolated (nonsyndromic) birth defect or as a syndromic anomaly in combination with other congenital dysmorphologies. The genetic causes of sagittal nonsyndromic craniosynostosis (NSC) remain unknown. Although variation of the dysmorphic (scaphocephaly) skull shape of sagittal NSC cases has been acknowledged, this variation has not been quantitatively studied three-dimensionally (3D). We have analyzed the computed tomography skull images of 43 infants (aged 0.9–9 months) with sagittal NSC using anatomical landmarks and semilandmarks to quantify and characterize the within-sample phenotypic variation. Suture closure patterns were defined by dividing the sagittal suture into three sections (anterior, central, posterior) and coding each section as ‘closed’ or ‘fused’. Principal components analysis of the Procrustes shape coordinates representing the skull shape of 43 cases of NSC did not separate individuals by sex, chronological age, or dental stages of the deciduous maxillary first molar. However, analysis of suture closure pattern allowed separation of these data. The central section of the sagittal suture appears to be the first to fuse. Then, at least two different developmental paths towards complete fusion of the sagittal suture exist; either the anterior section or the posterior section is the second to fuse. Results indicate that according to the sequence of sagittal suture closure patterns, different craniofacial complex shapes are observed. The relationship between craniofacial shape and suture closure indicates not only which suture fused prematurely (in our case the sagittal suture), but also the pattern of the suture closure. Whether these patterns indicate differences in etiology cannot be determined with our data and requires analysis of longitudinal data, most appropriately of animal models where prenatal conditions can be monitored. PMID:20572900

  13. Photocatalytic and antibacterial properties of a TiO2/nylon-6 electrospun nanocomposite mat containing silver nanoparticles.

    PubMed

    Pant, Hem Raj; Pandeya, Dipendra Raj; Nam, Ki Taek; Baek, Woo-Il; Hong, Seong Tshool; Kim, Hak Yong

    2011-05-15

    Silver-impregnated TiO(2)/nylon-6 nanocomposite mats exhibit excellent characteristics as a filter media with good photocatalytic and antibacterial properties and durability for repeated use. Silver nanoparticles (NPs) were successfully embedded in electrospun TiO(2)/nylon-6 composite nanofibers through the photocatalytic reduction of silver nitrate solution under UV-light irradiation. TiO(2) NPs present in nylon-6 solution were able to cause the formation of a high aspect ratio spider-wave-like structure during electrospinning and facilitated the UV photoreduction of AgNO(3) to Ag. TEM images, UV-visible and XRD spectra confirmed that monodisperse Ag NPs (approximately 4 nm in size) were deposited selectively upon the TiO(2) NPs of the prepared nanocomposite mat. The antibacterial property of a TiO(2)/nylon-6 composite mat loaded with Ag NPs was tested against Escherichia coli, and the photoactive property was tested against methylene blue. All of the results showed that TiO(2)/nylon-6 nanocomposite mats loaded with Ag NPs are more effective than composite mats without Ag NPs. The prepared material has potential as an economically friendly photocatalyst and water filter media because it allows the NPs to be reused.

  14. Revisiting the Variscan transpressional tectonics in the Southwestern Iberian suture

    NASA Astrophysics Data System (ADS)

    Pérez Cáceres, Irene; Martínez Poyatos, David; Simancas, José Fernando; Azor, Antonio

    2014-05-01

    The boundary between the Ossa-Morena Zone (OMZ) and the South Portuguese Zone (SPZ) in southwest Iberia is a Variscan collisional suture with transpressive left-lateral kinematics, contrasting with the dextral component that characterizes most of the Variscan convergence in other regions of the Orogen. Recent work including new structural and radiometric data has improved our knowledge on the geometry and timing of deformations affecting the OMZ/SPZ suture, which can be summarized as follows: Closure of the Rheic Ocean in Late Devonian time is attested by high-pressure and ophiolitic thin allochthonous units emplaced on the southern border of the OMZ. The kinematic interpretation of early stretching lineations and tectonic fabrics indicate that these units were emplaced in a tectonic regime of oblique left-lateral convergence. Transient transtension in Early Carboniferous time gave way to a narrow aisle of newly-formed oceanic-like crust just over the foregoing Rheic Ocean suture, accompanied by mafic magmatism intruded/extruded at both continental sides. Radiometric dating has yielded the same age of around 340 Ma for the oceanic-like mafic protholiths and their granulite/amphibolite facies tectonic fabric, thus indicating the very ephemeral life of the oceanic-like strip. Oblique convergence was resumed immediately after transtension, first causing northward obduction of the oceanic-like unit and north-verging folding in metasedimentary units of the southern border of the suture. Later on, a south-vergent regional fold was developed synchronous with left-lateral granulite-amphibolite facies shearing. Finally, shear deformation gave way to a low pitch stretching lineation, thrusting the OMZ over SPZ, concentrated on the southern limb of this regional fold and constituting a complex ductile 2-3 km-thick shear band evolving from amphibolite to greenschist facies, developing: (i) high-temperature greenschists at the southern border of the mafic oceanic-like unit

  15. Degranulation and abnormal bactericidal function of granulocytes procured by reversible adhesion to nylon wool.

    PubMed

    Klock, J C; Bainton, D F

    1976-07-01

    Granylocyte bactericidal capacity, chemotaxis, hexose monophosphate shung activity (before and after phagocytic stimulus), and quantitative nitroblue tetrazolium reduction and enzyme content were examined in cells obtained by filtration leukaphresis (FL) and continuous-flow centrifugation (CFC). A decrease in the bactericidal efficiency of FL-produced cells compared to that of both normal and CFC-procured granulocytes was found; the decrease was 17% with a cell-to-bacteria ratio of 5:1, and 55% with a 1:1 ratio. Moreover, FL-acquired cells were often vacuolated and consistently contained less acid phosphatase and beta-glucuronidase than did normal granulocytes. When normal cells were incubated for 1-2 hr with nylon wool, 30% of the total acid phosphatase and beta-glucuronidase was released, with no evidence of cell death, thus suggesting degranulation. Similar results were obtained with glass, cotton, or polysulfone plastic fibers. Electron microscopic and peroxidase cytochemical studies of the adherence of normal granulocytes to nylon fibers were also carried out. After 30 min of incubation, cell-to-fiber attachment and cellular aggregation had occurred, although the cells per se appeared normal. After 60 and 120 min, other changes became apparent: (1) a decrease in the amount of cytoplasmic granules; (2) large, intracytoplasmic vaculoles; and (3) extracellular peroxidase on fiber surfaces. We conclude that granulocytes obtained by adherence to nylon fibers show both morphological and biochemical evidence of degranulation and diminished bactericidal capacity, and that these abnormalities may be causally related to decreased granulocyte survival in transfusion recipients.

  16. MicroArray Facility: a laboratory information management system with extended support for Nylon based technologies

    PubMed Central

    Honoré, Paul; Granjeaud, Samuel; Tagett, Rebecca; Deraco, Stéphane; Beaudoing, Emmanuel; Rougemont, Jacques; Debono, Stéphane; Hingamp, Pascal

    2006-01-01

    Background High throughput gene expression profiling (GEP) is becoming a routine technique in life science laboratories. With experimental designs that repeatedly span thousands of genes and hundreds of samples, relying on a dedicated database infrastructure is no longer an option. GEP technology is a fast moving target, with new approaches constantly broadening the field diversity. This technology heterogeneity, compounded by the informatics complexity of GEP databases, means that software developments have so far focused on mainstream techniques, leaving less typical yet established techniques such as Nylon microarrays at best partially supported. Results MAF (MicroArray Facility) is the laboratory database system we have developed for managing the design, production and hybridization of spotted microarrays. Although it can support the widely used glass microarrays and oligo-chips, MAF was designed with the specific idiosyncrasies of Nylon based microarrays in mind. Notably single channel radioactive probes, microarray stripping and reuse, vector control hybridizations and spike-in controls are all natively supported by the software suite. MicroArray Facility is MIAME supportive and dynamically provides feedback on missing annotations to help users estimate effective MIAME compliance. Genomic data such as clone identifiers and gene symbols are also directly annotated by MAF software using standard public resources. The MAGE-ML data format is implemented for full data export. Journalized database operations (audit tracking), data anonymization, material traceability and user/project level confidentiality policies are also managed by MAF. Conclusion MicroArray Facility is a complete data management system for microarray producers and end-users. Particular care has been devoted to adequately model Nylon based microarrays. The MAF system, developed and implemented in both private and academic environments, has proved a robust solution for shared facilities and

  17. Research on the melt impregnation of continuous carbon fiber reinforced nylon 66 composites

    NASA Astrophysics Data System (ADS)

    Jia, M. Y.; Li, C. X.; Xue, P.; Chen, K.; Chen, T. H.

    2016-07-01

    Impregnation mold of continuous carbon fiber reinforced thermoplastic composites was designed and built in the article. Based on the theory of fluid mechanics and Darcy's law, a model of the melt impregnation was also established. The influences of fiber bundle width and impregnation pins’ diameter on the impregnation degree were studied by numerical simulation. Continuous carbon fiber reinforced nylon 66 composites were prepared. The effects of coated angle and impregnation mold temperature on the mechanical properties of the composites were also described.The agreement between the experimental data and prediction by the model was found to be satisfactory.

  18. 3D printing of weft knitted textile based structures by selective laser sintering of nylon powder

    NASA Astrophysics Data System (ADS)

    Beecroft, M.

    2016-07-01

    3D printing is a form of additive manufacturing whereby the building up of layers of material creates objects. The selective laser sintering process (SLS) uses a laser beam to sinter powdered material to create objects. This paper builds upon previous research into 3D printed textile based material exploring the use of SLS using nylon powder to create flexible weft knitted structures. The results show the potential to print flexible textile based structures that exhibit the properties of traditional knitted textile structures along with the mechanical properties of the material used, whilst describing the challenges regarding fineness of printing resolution. The conclusion highlights the potential future development and application of such pieces.

  19. Shear-induced conformation change in α-crystalline nylon6

    SciTech Connect

    Arabnejad, Saeid; Manzhos, Sergei; Shim, V. P. W.; He, Chaobin

    2014-12-01

    A study of shear deformation of α-crystalline nylon6 is undertaken, using dispersion-corrected density functional theory. The shear stress-strain relationship and shear strength for interlayer shear deformation are computed. A conformation change induced by shear is identified along twinning deformation, whereby the conformation of chains, specifically the location of non-H-bonded hydrogen atoms, changes continuously. This paves a way for the modulation of properties of this group of materials by small shear deformation, if the non-H-bonded hydrogens are chemically substituted to form non-equivalent conformations when deformed.

  20. FAST TRACK COMMUNICATION: Deposition of amino-rich thin films by RF magnetron sputtering of nylon

    NASA Astrophysics Data System (ADS)

    Kylián, O.; Hanuš, J.; Choukourov, A.; Kousal, J.; Slavínská, D.; Biederman, H.

    2009-07-01

    RF magnetron sputtering of a nylon target in different gas mixtures was studied in order to evaluate the capability of this process to deposit amino-rich coatings needed in a wide range of biomedical applications. It has been demonstrated that both the deposition rate of the coatings and the surface density of primary amino groups are strongly linked with working gas mixture composition. From this point of view, a sufficiently high deposition rate as well as the highest amine efficiency reaching a NH2/C value of 18% was observed in the N2/H2 discharge, which leads to the surface exhibiting a high rate of protein adsorption.

  1. A combined mode fatigue model for glass reinforced nylon as applied to molded engine cooling fans

    SciTech Connect

    Smith, J.D.; Bennet, M.L.

    1985-01-01

    The use of glass reinforced nylon in fatigue inducing environments calls for a new method of stress analysis. With an engine cooling fan, both mean and vibratory stresses need to be examined. Speed cycling can cause tensile fatigue, while vibration can cause flexural fatigue. Since tensile and flexural stresses exist in the fan simultaneously, a combined mode fatigue model is needed. The proposed model is based on high cycle flexural and tensile fatigue strengths, and tensile strength. It relates measurable strain to stress using temperature dependent flexural and tensile moduli, and treats underhood temperature and desired product life as variables.

  2. The Importance of Craniofacial Sutures in Biomechanical Finite Element Models of the Domestic Pig

    PubMed Central

    Bright, Jen A.

    2012-01-01

    Craniofacial sutures are a ubiquitous feature of the vertebrate skull. Previous experimental work has shown that bone strain magnitudes and orientations often vary when moving from one bone to another, across a craniofacial suture. This has led to the hypothesis that craniofacial sutures act to modify the strain environment of the skull, possibly as a mode of dissipating high stresses generated during feeding or impact. This study tests the hypothesis that the introduction of craniofacial sutures into finite element (FE) models of a modern domestic pig skull would improve model accuracy compared to a model without sutures. This allowed the mechanical effects of sutures to be assessed in isolation from other confounding variables. These models were also validated against strain gauge data collected from the same specimen ex vivo. The experimental strain data showed notable strain differences between adjacent bones, but this effect was generally not observed in either model. It was found that the inclusion of sutures in finite element models affected strain magnitudes, ratios, orientations and contour patterns, yet contrary to expectations, this did not improve the fit of the model to the experimental data, but resulted in a model that was less accurate. It is demonstrated that the presence or absence of sutures alone is not responsible for the inaccuracies in model strain, and is suggested that variations in local bone material properties, which were not accounted for by the FE models, could instead be responsible for the pattern of results. PMID:22363727

  3. Interactive Virtual Suturing Simulations: Enhancement of Student Learning in Veterinary Medicine

    ERIC Educational Resources Information Center

    Staton, Amy J.; Boyd, Christine B.

    2013-01-01

    This capstone addresses an instructional gap in the Morehead State University Veterinary Technology Program and in other similar programs around the globe. Students do not retain the knowledge needed to proficiently complete suture patterns nor do students receive sufficient instructional time during the year to master each suture pattern that is…

  4. 77 FR 8117 - Medical Devices; Cardiovascular Devices; Classification of the Endovascular Suturing System

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-14

    ... HUMAN SERVICES Food and Drug Administration 21 CFR Part 870 Medical Devices; Cardiovascular Devices; Classification of the Endovascular Suturing System AGENCY: Food and Drug Administration, HHS. ACTION: Final rule. SUMMARY: The Food and Drug Administration (FDA) is classifying the endovascular suturing system into...

  5. Arthroscopic repair of peripheral triangular fibrocartilage complex tears with suture welding: a technical report.

    PubMed

    Badia, Alejandro; Jiménez, Alexis

    2006-10-01

    This report presents a method of arthroscopic repair of the peripheral triangular fibrocartilage complex tears that replaces traditional suture knots with ultrasonic welding of sutures. This will help eliminate potential causes of ulnar-sided wrist discomfort during the postoperative period.

  6. A novel suture retention test for scaffold strength characterization in ophthalmology.

    PubMed

    Küng, Florian; Schubert, Dirk W; Stafiej, Piotr; Kruse, Friedrich E; Fuchsluger, Thomas A

    2016-12-01

    Sutures are a common way to attach scaffolds in patients. For tubular cardiac scaffolds, the 'suture retention strength' is commonly used to evaluate the resistance of a scaffold against the pull-out of a suture. In order to make this quantity accessible for ophthalmological scaffolds the test procedure has been modified in a novel way. Polycaprolactone (PCL) films of different thicknesses and an amniotic membrane (AM) were used for the experiments. Circular samples with a radius of 7mm were taken and a suture was passed through each sample and tied to a loop. The sample was clamped in a tensile tester and a bolt was passed through the loop. The suture was then pulled with a constant deformation rate until pull-out occurred. The suture retention strength, the deformation at the suture retention strength, and the deformation at rupture were determined for each sample. The presented modified suture retention test allows to measure the relevant parameters of samples on the scale of ophthalmological scaffolds in a reproducible way. A comparison between the first data on PCL and AM has been made. PMID:27612789

  7. Mechanical Properties of Cranial Bones and Sutures in 1–2-Year-Old Infants

    PubMed Central

    Wang, Jiawen; Zou, Donghua; Li, Zhengdong; Huang, Ping; Li, Dongri; Shao, Yu; Wang, Huijun; Chen, Yijiu

    2014-01-01

    Background The mechanical properties of 1–2-year-old pediatric cranial bones and sutures and their influential factors were studied to better understand how the pediatric calvarium reacts to loading. Material/Methods Cranial bone and suture specimens were extracted from seven fresh-frozen human infant cadavers (1.5±0.5 years old). Eight specimens were obtained from each subject: two frontal bones, two parietal bones, two sagittal suture samples, and two coronal suture samples. The specimens were tested in a three-point bend setup at 1.5 mm/s. The mechanical properties, such as ultimate stress, elastic modulus, and ultimate strain, were calculated for each specimen. Results The ultimate stress and elastic modulus of the frontal bone were higher than those of the parietal bone (P<0.05). No differences were found between the coronal and sagittal sutures in ultimate stress, elastic modulus, or ultimate strain (P>0.05). The ultimate stress and elastic modulus of the frontal and parietal bones were higher than those of the sagittal and coronal sutures (P<0.05), whereas the opposite ultimate strain findings were revealed (P<0.05). Conclusions There was no significant difference in ultimate stress, elastic modulus, or ultimate strain between the sagittal and coronal sutures. However, there were significant differences in ultimate stress, elastic modulus, and ultimate strain between the frontal and parietal bones as well as between the cranial bones and sutures. PMID:25279966

  8. Bacterial colonization on different suture materials--a potential risk for intraoral dentoalveolar surgery.

    PubMed

    Otten, J-E; Wiedmann-Al-Ahmad, M; Jahnke, H; Pelz, K

    2005-07-01

    In this in vivo and in vitro study on resorbable (Monocryl and nonresorbable (Deknalon) monofilament sutures used in intraoral dentoalveolar surgery the bacterial colonization was compared. For the in vivo study the sutures were applied in 11 patients during dental surgery. Eight days postoperative the sutures were removed and the adhered bacteria were isolated and identified by biochemistry, morphology, antibiotic susceptibility, and gas chromatography. The colonization was studied by scanning electron microscopy. Aerobic and anaerobic bacteria were isolated in nearly equal colony-forming units (cfu) on each suture. In comparison with Monocryl about 15% more aerobic and anaerobic strains were isolated on Deknalon. Regarding the pathogens only, about three times more anaerobic strains were isolated on both sutures in total. Additionally, more pathogens were found on Deknalon than on Monocryl (aerobic >40%, anaerobic >25%). The variety of bacteria correspond with purulent infections, not with normal oral flora. Intraindividual comparisons of cfu showed differences in dependence of the patient as described for subgingivale plaques. For the in vitro study the sutures were incubated with Streptococcus intermedius and Prevotella intermedia for 0.5 h. Scanning electron microscopy was performed to examine qualitatively the level of bacterial adherence. After 0.5 h the bacteria adhered very well. The colonization rate of Streptococcus intermedius on both sutures was similar. Coccoid bacteria within biofilms were seen. The growth of Prevotella intermedia was much better on Deknalon than on Monocryl. The risk of bacteremia at the time of suture removal is discussed.

  9. A mathematical model for mechanotransduction at the early steps of suture formation

    PubMed Central

    Khonsari, R. H.; Olivier, J.; Vigneaux, P.; Sanchez, S.; Tafforeau, P.; Ahlberg, P. E.; Di Rocco, F.; Bresch, D.; Corre, P.; Ohazama, A.; Sharpe, P. T.; Calvez, V.

    2013-01-01

    Growth and patterning of craniofacial sutures is subjected to the effects of mechanical stress. Mechanotransduction processes occurring at the margins of the sutures are not precisely understood. Here, we propose a simple theoretical model based on the orientation of collagen fibres within the suture in response to local stress. We demonstrate that fibre alignment generates an instability leading to the emergence of interdigitations. We confirm the appearance of this instability both analytically and numerically. To support our model, we use histology and synchrotron X-ray microtomography and reveal the fine structure of fibres within the sutural mesenchyme and their insertion into the bone. Furthermore, using a mouse model with impaired mechanotransduction, we show that the architecture of sutures is disturbed when forces are not interpreted properly. Finally, by studying the structure of sutures in the mouse, the rat, an actinopterygian (Polypterus bichir) and a placoderm (Compagopiscis croucheri), we show that bone deposition patterns during dermal bone growth are conserved within jawed vertebrates. In total, these results support the role of mechanical constraints in the growth and patterning of craniofacial sutures, a process that was probably effective at the emergence of gnathostomes, and provide new directions for the understanding of normal and pathological suture fusion. PMID:23516237

  10. Experimental investigation of transport of discrete solids with surge flows in a 10.0 cm diameter partially filled pipe

    NASA Astrophysics Data System (ADS)

    Mahajan, B. M.

    1982-01-01

    The transport of discrete solids with surge flows in a partially filled slightly pitched horizontal pipe was investigated. The experimental apparatus, instrumentation, and procedures are described. The experiments were conducted using a cylindrical solid in a 10.0 cm (4 in) diameter pipe. The water surge flows were obtained by discharging different volumes of water into the pipe from a falling head open container which simulated a water closet. Flow induced solid velocities and stream depth histories at various locations along the length of the pipe were measured. The effects of water volume used, pipe slope, and size of the solid on the solid velocities were examined. Solid velocities were compared with the maximum water velocities estimated from the stream depth histories. Also, the distance traversed by the solids in the pipe were measured for those cases in which the solids did not clear the pipe. The solid velocity increased with an increase in water volume used, a decrease in the size of the solid, and an increase in the pipe slope. The solid velocity in the initial reach of the pipe was less than the maximum water velocity; and the solid velocity approaches the maximum water velocity as the solid traveled downstream, except for some experiments with small water volumes.

  11. Bis-GMA/TEGDMA Dental Composites Reinforced with Electrospun Nylon 6 Nanocomposite Nanofibers Containing Highly Aligned Fibrillar Silicate Single Crystals.

    PubMed

    Tian, Ming; Gao, Yi; Liu, Yi; Liao, Yiliang; Xu, Riwei; Hedin, Nyle E; Fong, Hao

    2007-04-24

    The objective of this research was to study the reinforcement of electrospun nylon 6/fibrillar silicate nanocomposite nanofibers on Bis-GMA/TEGDMA dental composites. The hypothesis was that the uniform distribution of nano-scaled and highly aligned fibrillar silicate single crystals into electrospun nylon 6 nanofibers would improve the mechanical properties of the resulting nanocomposite nanofibers, and would lead to the effective reinforcement of dental composites. The nylon 6/fibrillar silicate nanocomposite nanofibers were crystalline, structurally oriented and had an average diameter of approximately 250 nm. To relatively well distribute nanofibers in dental composites, the nanofiber containing composite powders with a particle structure similar to that in interpenetration networks were prepared first, and then used to make the dental composites. The results indicated that small mass fractions (1 % and 2 %) of nanofiber impregnation improved the mechanical properties substantially, while larger mass factions (4 % and 8 %) of nanofiber impregnation resulted in less desired mechanical properties.

  12. Application of pervaporation and vapor permeation processes to separate aqueous ethanol solution through chemically modified Nylon 4 membranes

    SciTech Connect

    Wang, Y.H.; Teng, M.Y.; Lee, K.R.; Wang, D.M.; Lai, J.Y.

    1998-08-01

    The pervaporation performance of a Nylon 4 membrane, chemically grafted by N,N-dimethylaminoethyl methacrylate (DMAEM), DMAEM-g-N4, was studied by measurement of the permeation ratio and the pervaporation separation index. It was found that the water permselectivity and permeation rate for the chemically modified Nylon 4 membrane were higher than those of the unmodified Nylon 4 membrane. Optimum pervaporation results, a separation factor of 28.3, and a permeation rate of 439 g/m{sup 2}{center_dot}h, were obtained when the degree of grafting was 12.7%. It was also found that all the permeation ratios at low temperature were less than unity. In addition, compared with pervaporation, vapor permeation effectively increases the permselectivity of water.

  13. Accuracy of Suture Passage During Arthroscopic Remplissage—What Anatomic Landmarks Can Improve It?

    PubMed Central

    Garcia, Grant H.; Degen, Ryan M.; Liu, Joseph N.; Kahlenberg, Cynthia A.; Dines, Joshua S.

    2016-01-01

    Background: Recent data suggest that inaccurate suture passage during remplissage may contribute to a loss of external rotation, with the potential to cause posterior shoulder pain because of the proximity to the musculotendinous junction. Purpose: To evaluate the accuracy of suture passage during remplissage and identify surface landmarks to improve accuracy. Study Design: Descriptive laboratory study. Methods: Arthroscopic remplissage was performed on 6 cadaveric shoulder specimens. Two single-loaded suture anchors were used for each remplissage. After suture passage, position was recorded in reference to the posterolateral acromion (PLA), with entry perpendicular to the humeral surface. After these measurements, the location of posterior cuff penetration was identified by careful surgical dissection. Results: Twenty-four sutures were passed in 6 specimens: 6 sutures (25.0%) were correctly passed through the infraspinatus tendon, 12 (50%) were through the infraspinatus muscle or musculotendinous junction (MTJ), and 6 (25%) were through the teres minor. Suture passage through the infraspinatus were on average 25 ± 5.4 mm inferior to the PLA, while sutures passing through the teres minor were on average 35.8 ± 5.7 mm inferior to the PLA. There was an odds ratio of 25 (95% CI, 2.1-298.3; P < .001) that the suture would be through the infraspinatus if the passes were less than 3 cm inferior to the PLA. Sutures passing through muscle and the MTJ were significantly more medial than those passing through tendon, measuring on average 8.1 ± 5.1 mm lateral to the PLA compared with 14.5 ± 5.5 mm (P < .02). If suture passes were greater than 1 cm lateral to the PLA, it was significantly more likely to be in tendon (P = .013). Conclusion: We found remplissage suture passage was inaccurate, with only 25% of sutures penetrating the infraspinatus tendon. Passing sutures 1 cm lateral and within 3 cm inferior of the PLA improves the odds of successful infraspinatus tenodesis

  14. Responses of intramembranous bone and sutures upon in vivo cyclic tensile and compressive loading.

    PubMed

    Peptan, Alexandra I; Lopez, Aurora; Kopher, Ross A; Mao, Jeremy J

    2008-02-01

    Cranial vault and facial sutures interpose between mineralized bones of the skull, and may function analogously to appendicular and cranial base growth plates. However, unlike growth plates that are composed of chondrocyte lineage, cranial and facial sutures possess heterogeneous cell lineages such as mesenchymal cells, fibroblasts, and osteoblasts, in addition to vascular-derived cells. Despite recently intensified effort, the biological responses of intramembranous bone and sutures to mechanical loading are not well understood. This study was designed to investigate whether brief doses of tensile or compressive forces induce modeling and growth responses of intramembranous bone and sutures. In different groups of growing rabbits in vivo, cyclic tensile or compressive forces at 1 N and 8 Hz were applied to the maxilla for 20 min/day over 12 consecutive days. Computerized histomorphometric analyses revealed that the average sutural widths of both the premaxillomaxillary suture (PMS) and nasofrontal suture (NFS) loaded in either tension or compression were significantly higher than age- and sex-matched sham controls (P<0.01). The average cell densities of tension- or compression-loaded PMS and NFS were significantly higher than sham controls (P<0.01). The average osteoblast occupied sutural bone surface loaded under tension was significantly higher than that of sham control (P<0.05). Interestingly, tensile loading significantly reduced the average osteoclast surface, in comparison to sham control (P<0.05). For the NFS, tensile loading significantly increased the average osteoblast occupied sutural bone surface, in comparison with that of sham control (P<0.05). Also for the NFS suture, compression significantly reduced the average sutural osteoclast surface in comparison with sham control (P<0.05). Taken together, the present data suggest that high-frequency cyclic forces in either tension or compression induce modeling and growth changes in cranial sutures. Due to

  15. Accuracy of Suture Passage During Arthroscopic Remplissage—What Anatomic Landmarks Can Improve It?

    PubMed Central

    Garcia, Grant H.; Degen, Ryan M.; Liu, Joseph N.; Kahlenberg, Cynthia A.; Dines, Joshua S.

    2016-01-01

    Background: Recent data suggest that inaccurate suture passage during remplissage may contribute to a loss of external rotation, with the potential to cause posterior shoulder pain because of the proximity to the musculotendinous junction. Purpose: To evaluate the accuracy of suture passage during remplissage and identify surface landmarks to improve accuracy. Study Design: Descriptive laboratory study. Methods: Arthroscopic remplissage was performed on 6 cadaveric shoulder specimens. Two single-loaded suture anchors were used for each remplissage. After suture passage, position was recorded in reference to the posterolateral acromion (PLA), with entry perpendicular to the humeral surface. After these measurements, the location of posterior cuff penetration was identified by careful surgical dissection. Results: Twenty-four sutures were passed in 6 specimens: 6 sutures (25.0%) were correctly passed through the infraspinatus tendon, 12 (50%) were through the infraspinatus muscle or musculotendinous junction (MTJ), and 6 (25%) were through the teres minor. Suture passage through the infraspinatus were on average 25 ± 5.4 mm inferior to the PLA, while sutures passing through the teres minor were on average 35.8 ± 5.7 mm inferior to the PLA. There was an odds ratio of 25 (95% CI, 2.1-298.3; P < .001) that the suture would be through the infraspinatus if the passes were less than 3 cm inferior to the PLA. Sutures passing through muscle and the MTJ were significantly more medial than those passing through tendon, measuring on average 8.1 ± 5.1 mm lateral to the PLA compared with 14.5 ± 5.5 mm (P < .02). If suture passes were greater than 1 cm lateral to the PLA, it was significantly more likely to be in tendon (P = .013). Conclusion: We found remplissage suture passage was inaccurate, with only 25% of sutures penetrating the infraspinatus tendon. Passing sutures 1 cm lateral and within 3 cm inferior of the PLA improves the odds of successful infraspinatus tenodesis

  16. Complications and pregnancy outcome following uterine compression suture for postpartum haemorrhage: a single centre experience.

    PubMed

    Liu, S; Mathur, M; Tagore, S

    2014-07-01

    In the treatment of postpartum haemorrhage from uterine atony, uterine compression sutures, such as the B-Lynch suture and its modifications have a role with the advantage of preservation of the uterus for fertility. There is however, a risk that apposition of the anterior and posterior walls of the uterus will impede drainage of lochia, resulting in undesirable complications. We undertook a five-year retrospective study of all women who underwent uterine compression sutures at the KK Women's and Children's Hospital, between 2008 and 2012. In total, 23 women had uterine compression sutures during the study period, of which, nineteen women managed to conserve their uterus. Our complication rate was 25%, which included persistent vaginal discharge, pyometra and endometritis. There were three conceptions, with two successful pregnancies. Our study shows uterine compression suture to be a safe and effective alternative to avoid hysterectomy with preservation of fertility at the time of major postpartum haemorrhage. The outcome of subsequent pregnancies is reassuring.

  17. Effects of myrrh on the strength of suture materials: an in vitro study.

    PubMed

    Alshehri, Mohammed A; Baskaradoss, Jagan Kumar; Geevarghese, Amrita; Ramakrishnaiah, Ravikumar; Tatakis, Dimitris N

    2015-01-01

    The present in vitro study sought to determine the effects of myrrh-containing solutions on common suture materials used in periodontal surgery. Three commonly used suture materials (silk, polyglactin 910, polytetrafluoroethylene) were immersed in four thermostatically controlled experimental media to simulate daily oral rinsing activity, namely -artificial saliva, normal saline solution with 0.2% Commiphora myrrh, full-concentration (100%) Commiphora myrrh oil, and a myrrh-containing commercial mouthwash. Tensile strength was measured at the end of each day using an Instron tensile testing machine. Silk sutures were susceptible to tensile strength loss when exposed to 0.2% myrrh solution once daily for 5 days. Myrrh-containing commercial mouthwash had no effect on tensile strength, but all three suture materials lost tensile strength when exposed to 100% myrrh oil. For patients that routinely use myrrh mouthwashes postoperatively, findings of this study suggested that silk sutures might not be the optimal material choice. PMID:25736257

  18. Small bowel obstruction from barbed suture following laparoscopic myomectomy—A case report

    PubMed Central

    Lee, Eric Tat Choi; Wong, Felix Wu Shun

    2015-01-01

    Myomectomy is commonly performed for symptomatic fibroids in women who wish to conserve fertility. Laparoscopic myomectomy provides advantages as a minimally invasive procedure. To facilitate the closure of the uterine wound after enucleation of the fibroid, barbed sutures have been introduced as they can shorten the operative time and reduce the amount of bleeding. However, the use of barbed suture is not without risk. There were a few reports on the risks of barbed sutures in the literature. We report herein a case of acute abdomen because of small bowel entrapment and obstruction following the use of barbed suture in laparoscopic myomectomy. Surgeons using barbed suture in myomectomy should be vigilant on the possibility of this bowel complication whenever adverse clinical situation arises as the outcome could be serious if the condition was left unchecked. PMID:26454501

  19. Celastrol nanoparticles inhibit corneal neovascularization induced by suturing in rats

    PubMed Central

    Li, Zhanrong; Yao, Lin; Li, Jingguo; Zhang, Wenxin; Wu, Xianghua; Liu, Yi; Lin, Miaoli; Su, Wenru; Li, Yongping; Liang, Dan

    2012-01-01

    Purpose Celastrol, a traditional Chinese medicine, is widely used in anti-inflammation and anti-angiogenesis research. However, the poor water solubility of celastrol restricts its further application. This paper aims to study the effect of celastrol nanoparticles (CNPs) on corneal neovascularization (CNV) and determine the possible mechanism. Methods To improve the hydrophilicity of celastrol, celastrol-loaded poly(ethylene glycol)-block-poly(ɛ-caprolactone) nanopolymeric micelles were developed. The characterization of CNPs was measured by dynamic light scattering and transmission electron microscopy analysis. Celastrol loading content and release were assessed by ultraviolet-visible analysis and high performance liquid chromatography, respectively. In vitro, human umbilical vein endothelial cell proliferation and capillary-like tube formation were assayed. In vivo, suture-induced CNV was chosen to evaluate the effect of CNPs on CNV in rats. Immunohistochemistry for CD68 assessed the macrophage infiltration of the cornea on day 6 after surgery. Real-time quantitative reverse transcription-polymerase chain reaction and enzyme-linked immunosorbent assay were used to evaluate the messenger ribonucleic acid and protein levels, respectively, of vascular endothelial growth factor, matrix metalloproteinase 9, and monocyte chemoattractant protein 1 in the cornea. Results The mean diameter of CNPs with spherical shape was 48 nm. The celastrol loading content was 7.36%. The release behavior of CNPs in buffered solution (pH 7.4) showed a typical two-phase release profile. CNPs inhibited the proliferation of human umbilical vein endothelial cells in a dose-independent manner and suppressed the capillary structure formation. After treatment with CNPs, the length and area of CNV reduced from 1.16 ± 0.18 mm to 0.49 ± 0.12 mm and from 7.71 ± 0.94 mm2 to 2.29 ± 0.61 mm2, respectively. Macrophage infiltration decreased significantly in the CNP-treated corneas. CNPs reduced

  20. Three-dimensional densitometric analysis of maxillary sutural changes induced by rapid maxillary expansion

    PubMed Central

    Lione, R; Franchi, L; Fanucci, E; Laganà, G; Cozza, P

    2013-01-01

    Objective: This prospective study evaluated the density of the midpalatal and transverse sutures as assessed by low-dose CT before rapid maxillary expansion (T0), at the end of active expansion (T1) and after a retention period of 6 months (T2). Methods: The study sample comprised 17 pre-pubertal subjects (mean age 11.2 years) with constricted maxillary arches. Total amount of expansion was 7 mm in all subjects. Multislice low-dose CT scans were taken at T0, T1 and T2. On the axial CT scanned images six regions of interest (ROIs) were placed along the midpalatal and transverse sutures and two in maxillary and palatal bony areas. Density was measured in Hounsfield units. Mann–Whitney U test and Friedman analysis of variance with post hoc tests were used (p < 0.05). Results: The three ROIs in the midpalatal suture showed a significant decrease in density from T0 to T1, a significant increase from T1 to T2 and a lack of statistically significant differences from T0 to T2. Both ROIs located in the transverse suture showed a significant decrease in density from T0 to T1, followed by a non-significant increase in density from T1 to T2. Conclusions: At the end of the active phase of expansion a significant reduction in density along the midpalatal and transverse sutures was observed in all subjects. The sutural density of the midpalatal suture at T2 indicated reorganization of the midpalatal suture while the density along the transverse suture increased without reaching the pre-treatment values, possibly due to different morphology between midpalatal and transverse sutures. PMID:22996394

  1. Microbiology of Explanted Suture Segments from Infected and Noninfected Surgical Patients

    PubMed Central

    Krepel, Candace J.; Marks, Richard M.; Rossi, Peter J.; Sanger, James; Goldblatt, Matthew; Graham, Mary Beth; Rothenburger, Stephen; Collier, John; Seabrook, Gary R.

    2013-01-01

    Sutures under selective host/environmental factors can potentiate postoperative surgical site infection (SSI). The present investigation characterized microbial recovery and biofilm formation from explanted absorbable (AB) and nonabsorbable (NAB) sutures from infected and noninfected sites. AB and NAB sutures were harvested from noninfected (70.9%) and infected (29.1%) sites in 158 patients. At explantation, devices were sonicated and processed for qualitative/quantitative bacteriology; selective sutures were processed for scanning electron microscopy (SEM). Bacteria were recovered from 85 (53.8%) explanted sites; 39 sites were noninfected, and 46 were infected. Suture recovery ranged from 11.1 to 574.6 days postinsertion. A significant difference in mean microbial recovery between noninfected (1.2 isolates) and infected (2.7 isolates) devices (P < 0.05) was noted. Staphylococcus epidermidis, Staphylococcus aureus, coagulase-negative staphylococci (CNS), Peptostreptococcus spp., Bacteroides fragilis, Escherichia coli, Enterococcus spp., Pseudomonas aeruginosa, and Serratia spp. were recovered from infected devices, while commensal skin flora was recovered from noninfected devices. No significant difference in quantitative microbial recovery between infected monofilament and multifilament sutures was noted. Biofilm was present in 100% and 66.6% of infected and noninfected devices, respectively (P < 0.042). We conclude that both monofilament and braided sutures provide a hospitable surface for microbial adherence: (i) a significant difference in microbial recovery from infected and noninfected sutures was noted, (ii) infected sutures harbored a mixed flora, including multidrug-resistant health care-associated pathogens, and (iii) a significant difference in the presence or absence of a biofilm in infected versus noninfected explanted devices was noted. Further studies to document the benefit of focused risk reduction strategies to minimize suture contamination and

  2. Synthesis of Ag/CNT hybrid nanoparticles and fabrication of their nylon-6 polymer nanocomposite fibers for antimicrobial applications.

    PubMed

    Rangari, Vijaya K; Mohammad, Ghouse M; Jeelani, Shaik; Hundley, Angel; Vig, Komal; Singh, Shree Ram; Pillai, Shreekumar

    2010-03-01

    Ag-coated CNTs hybrid nanoparticles (Ag/CNTs) were prepared by ultrasonic irradiation of dimethylformamide (DMF) and silver (I) acetate precursors in the presence of CNTs. The morphology of Ag/CNTs was characterized using x-ray diffraction and transmission electron microscopy (TEM) techniques. The Nylon-6 powder and 1 wt% Ag/CNTs mixture was dispersed uniformly using a noncontact spinning technique. The dried mixture was melted in a single screw extrusion machine and then extruded through an orifice. Extruded filaments were later stretched and stabilized by sequentially passing them through a set of tension adjusters and a secondary heater. The Nylon-6/Ag/CNT hybrid polymer nanocomposite (HPNC) fibers, which were of approximately 80 microm size, were tested for their tensile properties. The failure stress and modulus of the extruded HPNC fibers (doped with 1% Ag/CNTs) was about 72.19 % and 342.62% higher than the neat extruded Nylon-6 fiber, respectively. DSC results indicated an increase in the thermal stability and crystallization for HPNC fibers. The antibacterial activity of the Ag-coated CNTs, commercial Ag, neat Nylon-6 and plain CNTs were evaluated. Ag-coated CNTs at 25 microg demonstrated good antimicrobial activity against four common bacterial pathogens as tested by the Kirby-Bauer assay. The mean diameters of the zones of inhibition were 27.9 +/- 6.72 mm, 19.4 +/- 3.64 mm, 21.9 +/- 4.33 mm, and 24.1 +/- 4.14 mm, respectively, for Staphylococcus aureus, Streptococcus pyogenes, Escherichia coli and Salmonella enterica serovar Typhimurium. By comparison, those obtained using the broad spectrum antibiotic amoxicillin-clavulanic acid were 37.7 +/- 2.13 mm, 28.6 +/- 4.27 mm, 22.6 +/- 1.27 mm, and 27.0 +/- 1.41 mm, respectively, for the same strains. The zones of inhibition obtained for Nylon-6 Ag-coated CNT powder at 25 microg were also high, ranging from 15.2 to 25.3 mm in contrast to commercial silver or neat Nylon-6, which did not inhibit the bacterial

  3. Synthesis of Ag/CNT hybrid nanoparticles and fabrication of their Nylon-6 polymer nanocomposite fibers for antimicrobial applications

    NASA Astrophysics Data System (ADS)

    Rangari, Vijaya K.; Mohammad, Ghouse M.; Jeelani, Shaik; Hundley, Angel; Vig, Komal; Ram Singh, Shree; Pillai, Shreekumar

    2010-03-01

    Ag-coated CNTs hybrid nanoparticles (Ag/CNTs) were prepared by ultrasonic irradiation of dimethylformamide (DMF) and silver (I) acetate precursors in the presence of CNTs. The morphology of Ag/CNTs was characterized using x-ray diffraction and transmission electron microscopy (TEM) techniques. The Nylon-6 powder and 1 wt% Ag/CNTs mixture was dispersed uniformly using a noncontact spinning technique. The dried mixture was melted in a single screw extrusion machine and then extruded through an orifice. Extruded filaments were later stretched and stabilized by sequentially passing them through a set of tension adjusters and a secondary heater. The Nylon-6/Ag/CNT hybrid polymer nanocomposite (HPNC) fibers, which were of ~ 80 µm size, were tested for their tensile properties. The failure stress and modulus of the extruded HPNC fibers (doped with 1% Ag/CNTs) was about 72.19 % and 342.62% higher than the neat extruded Nylon-6 fiber, respectively. DSC results indicated an increase in the thermal stability and crystallization for HPNC fibers. The antibacterial activity of the Ag-coated CNTs, commercial Ag, neat Nylon-6 and plain CNTs were evaluated. Ag-coated CNTs at 25 µg demonstrated good antimicrobial activity against four common bacterial pathogens as tested by the Kirby-Bauer assay. The mean diameters of the zones of inhibition were 27.9 ± 6.72 mm, 19.4 ± 3.64 mm, 21.9 ± 4.33 mm, and 24.1 ± 4.14 mm, respectively, for Staphylococcus aureus, Streptococcus pyogenes, Escherichia coli and Salmonella enterica serovar Typhimurium. By comparison, those obtained using the broad spectrum antibiotic amoxicillin-clavulanic acid were 37.7 ± 2.13 mm, 28.6 ± 4.27 mm, 22.6 ± 1.27 mm, and 27.0 ± 1.41 mm, respectively, for the same strains. The zones of inhibition obtained for Nylon-6 Ag-coated CNT powder at 25 µg were also high, ranging from 15.2 to 25.3 mm in contrast to commercial silver or neat Nylon-6, which did not inhibit the bacterial strains tested. Further, the

  4. Virtual reality thread simulation for laparoscopic suturing training.

    PubMed

    Figueras Sola, Pablo J; Rodriguez Bescós, Samuel; Lamata, Pablo; Pagador, J Blas; Sánchez-Margallo, Francisco M; Gómez, Enrique J

    2006-01-01

    The level of realism in virtual reality trainers might not be proportional to its didactic value. As an example, three exercises to train suturing skills are proposed in this article. They use a discrete thread model with a simple but good enough behaviour, and constitute a training means for three laparoscopic skills: (1) Accurate grasping, which trains grasping a precise point in the thread. (2) Coordinated Pulling, which trains tightening the thread co-ordinately and in different space orientations; and (3) Knotting, which allow the surgeon to practice this manoeuvre. These three exercises, found interesting among experts in surgical training, are now being validated in MIS workshops at the Minimally Invasive Surgery Centre of Cáceres (Spain).

  5. Piezoelectric inkjet printing of a cross-hatch immunoassay on a disposable nylon membrane.

    PubMed

    Stewart, Thomas N; Pierson, Bonnie E; Aggarwal, Ravi; Narayan, Roger J

    2009-02-01

    The development of a cost-effective method for manufacturing immunoassays is a key step towards their commercial use. In this study, a piezoelectric inkjet printer and a nylon membrane were used to fabricate a disposable immunoassay. Using a piezoelectric inkjet printer, a cross-hatch pattern of goat anti-mouse antibody (GalphaM) and rabbit anti-horseradish peroxidase (RalphaHRP) antibody were deposited on the nylon membrane. These patterns were subsequently treated with a solution containing rabbit anti-goat antibody labeled with horseradish peroxidase (RalphaG-HRP). The effectiveness of the immobilization process was examined using tetramethylbenzidine (TMB), which oxidizes in the presence of HRP to form a visible precipitate. Optical evaluation of the TMB precipitate was used to assess the precision of the features in the inkjet-printed pattern as well as antibody functionality following inkjet printing. Uniform patterns that contained functional antibodies were fabricated using the piezoelectric inkjet printer. These results suggest that piezoelectric inkjet printing may be used to fabricate low-cost disposable immunoassays for biotechnology and healthcare applications. PMID:19226553

  6. Modification of nylon-6 fibres by radiation-induced graft polymerisation of vinylbenzyl chloride

    NASA Astrophysics Data System (ADS)

    Ting, T. M.; Nasef, Mohamed Mahmoud; Hashim, Kamaruddin

    2015-04-01

    Modification of nylon-6 fibres by radiation-induced graft copolymerisation (RIGP) of vinylbenzyl chloride (VBC) using the preirradiation method was investigated. A number of grafting parameters such as type of solvent, total dose, monomer concentrations, reaction temperature and reaction time were studied to obtain desired degree of grafting (DG). The DG was found to be a function of reaction parameters and achieved a maximum value of 130 wt% at 20 vol% VBC concentration in methanol, 300 kGy dose, 30 °C temperature and 3 h reaction time. Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray diffraction (XRD) were employed to evaluate the chemical, morphological and structural changes that occurred in the grafted fibres, respectively. Thermogravimetric analysis (TGA) was also applied to determine the thermal stability, whereas differential scanning calorimeter (DSC) and universal mechanical tester were used to analyse respective thermal and mechanical properties of the grafted fibres. The results of these analyses provide strong evidence for successful grafting of VBC onto nylon-6, and the variation in the properties of the grafted fibres depends on DG.

  7. Survey of Primary Aromatic Amines and Colorants in Polyurethane, Nylon and Textile Toys.

    PubMed

    Abe, Yutaka; Yamaguchi, Miku; Mutsuga, Motoh; Akiyama, Hiroshi; Kawamura, Yoko

    2016-01-01

    The residual and migration levels of 28 primary aromatic amines (PAAs) in polyurethane and nylon toys were determined using LC-MS/MS, and the migration and residual amounts of PAAs and 15 colorants in textile toys were determined using LC-MS/MS and LC-TOF-MS according to the European Standard EN71. Among 34 polyurethane toy samples, 2,6-diaminotoluene and 2,4-diaminotoluene were detected in the same 12 samples at residual levels ranging from 2.1 to 19.7 and from 7.6 to 39.6 μg/g, respectively. Furthermore, 4,4'-diaminodiphenylmethane (4,4'-MDA) and aniline were detected in 9 samples (from 0.2 to 8.7 μg/g), and one sample (0.4 μg/g), respectively. PAAs were not detected in the 8 samples of nylon toys. As for the migration test into water, only 4,4'-MDA migrated from 3 polyurethane toys at levels ranging from 0.4 to 2.5 μg/g. PAAs did not migrate from the 43 textile toys, but colorants such as Solvent Yellow 1 and Basic Red 9 were detected at the residual level of 0.02 μg/g. The residual levels of PAAs and colorants detected in this study were significantly lower than the limit values established by the European Union regulation. PMID:27211915

  8. A novel approach for application of nylon membranes in the biosensing domain

    NASA Astrophysics Data System (ADS)

    Farahmand, Elham; Ibrahim, Fatimah; Hosseini, Samira; Rothan, Hussin A.; Yusof, Rohana; Koole, Leo H.; Djordjevic, Ivan

    2015-10-01

    In this paper we report the polymer-coated microporous nylon membranes and their application as platforms for protein immobilization and subsequent detection of the dengue virus (DV) in blood serum. Protein recognition experiments were performed with enzyme-linked immunosorbent assay (ELISA). The polymers used for coatings were synthesized by free-radical polymerization reaction between methyl methacrylate (MMA) and methacrylic acid (MAA) in different concentrations. The MAA monomer has carefully been chosen to generate polymers with pendant carboxyl (-COOH) groups, which also exist on polymer surfaces. A high degree of control over surface-exposed -COOH groups has been achieved through variation of monomers concentration in polymerization reaction. The general aspect of this work relies on the dengue antibody (Ab) immobilization on surface -COOH groups via physical attachment or covalent immobilization. Prior to Ab immobilization and ELISA experiment, polymer-coated nylon samples were analyzed in detail for their physical properties by atomic force microscopy (AFM), scanning electron microscopy (SEM), and water-in-air contact angle (WCA) measurements. Membranes were further analyzed by Fourier transform infrared spectroscopy (FTIR) in order to establish the relationship between wettability, porosity, and surface roughness with chemical composition and concentration of -COOH groups on the coating's surface. Optimized coatings have shown high sensitivity towards dengue Ab molecules, revealing fundamental aspect of polymer-protein interfaces as a function of surface -COOH groups' concentration.

  9. Position control of fishing line artificial muscles (coiled polymer actuators) from nylon thread

    NASA Astrophysics Data System (ADS)

    Arakawa, Takeshi; Takagi, Kentaro; Tahara, Kenji; Asaka, Kinji

    2016-04-01

    Recently, fishing line artificial muscle has been developed and is paid much attention due to the properties such as large contraction, light weight and extremely low cost. Typical fishing line artificial muscle is made from Nylon thread and made by just twisting the polymer. In this paper, because of the structure of the actuator, such actuators may be named as coiled polymer actuators (CPAs). In this paper, a CPA is fabricated from commercial Nylon fishing line and Ni-Cr alloy (Nichrome) wire is wound around it. The CPA contracts by the Joule heat generated by applied voltage to the Nichrome wire. For designing the control system, a simple model is proposed. According to the physical principle of the actuator, two first-order transfer functions are introduced to represent the actuator model. One is a system from the input power to the temperature and the other is a system from the temperature to the deformation. From the system identification result, it is shown that the dominant dynamics is the system from the input power to the temperature. Using the developed model, position control of the voltage-driven CPA is discussed. Firstly, the static nonlinearity from the voltage to the power is eliminated. Then, a 2-DOF PID controller which includes an inversion-based feed forward controller and a PID controller are designed. In order to demonstrate the proposed controller, experimental verification is shown.

  10. Fabrication of porous calcite using chopped nylon fiber and its evaluation using rats.

    PubMed

    Ishikawa, Kunio; Tram, Nguyen Xuan Thanh; Tsuru, Kanji; Toita, Riki

    2015-02-01

    Although porous calcite has attracted attention as bone substitutes, limited studies have been made so far. In the present study, porous calcite block was fabricated by introducing chopped nylon fiber as porogen. Ca(OH)2 powder containing 10 wt% chopped nylon fiber was compacted at 150 MPa, and sintered to burn out the fiber and to carbonate the Ca(OH)2 under stream of 1:2 O2-CO2. Sintering of Ca(OH)2 at 750 °C or lower temperature resulted in incomplete burning out of the fiber whereas sintering at 800 °C or higher temperature resulted in the formation of CaO due to the thermal decomposition of Ca(OH)2. However, sintering at 770 °C resulted in complete burning out of the fiber and complete carbonation of Ca(OH)2 to calcite without forming CaO. Macro- and micro-porosities of the porous calcite were approximately 23 and 16%, respectively. Diameter of the macropores was approximately 100 μm which is suitable for bone tissue penetration. Porous calcite block fabricated by this method exhibited good tissue response when implanted in the bone defect in femur of 12-weeks-old rat. Four weeks after implantation, bone bonded on the surface of calcite. Furthermore, bone tissue penetrated interior to the macropore at 8 weeks. These results demonstrated the good potential value of porous calcite as artificial bone substitutes.

  11. Atrazine adsorption removal with nylon6/polypyrrole core-shell nanofibers mat: possible mechanism and characteristics.

    PubMed

    Yang, Bi-Yi; Cao, Yang; Qi, Fei-Fei; Li, Xiao-Qing; Xu, Qian

    2015-01-01

    A functionalized nylon6/polypyrrole core-shell nanofibers mat (PA6/PPy NFM) was prepared via situ polymerization on nylon6 electrospun nanofibers mat (PA6 NFM) template and used as an adsorbent to remove atrazine from aqueous solutions. The core-shell structure of PA6/PPy NFM can be clearly proved under scanning electron microscope (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). The effects of initial solution pH and ionic strength, as well as the comparison of the adsorption capacity of functionalized (PA6/PPy NFM) and non-functionalized (PA6 NFM) adsorbent, were examined to reveal the possible adsorption mechanism. The results indicated that π-π interaction and electrostatic interaction should play a key role in the adsorption process. The kinetics and thermodynamics studies also further elucidated the detailed adsorption characteristics of atrazine removal by PA6/PPy NFM. The adsorption of atrazine could be well described by the pseudo-second-order equation. The adsorption equilibrium data was well fitted with the Freundlich isotherm model with a maximum adsorption capacity value of 14.8 mg/g. In addition, the increase of adsorption rate caused by a temperature increase could be felicitously explained by the endothermic reaction. The desorption results showed that the adsorption capacity remained almost unchanged after six adsorption/desorption cycles. These results suggest that PA6/PPy NFM could be employed as an efficient adsorbent for removing atrazine from contaminated water sources. PMID:25991912

  12. Piezoelectric inkjet printing of a cross-hatch immunoassay on a disposable nylon membrane.

    PubMed

    Stewart, Thomas N; Pierson, Bonnie E; Aggarwal, Ravi; Narayan, Roger J

    2009-02-01

    The development of a cost-effective method for manufacturing immunoassays is a key step towards their commercial use. In this study, a piezoelectric inkjet printer and a nylon membrane were used to fabricate a disposable immunoassay. Using a piezoelectric inkjet printer, a cross-hatch pattern of goat anti-mouse antibody (GalphaM) and rabbit anti-horseradish peroxidase (RalphaHRP) antibody were deposited on the nylon membrane. These patterns were subsequently treated with a solution containing rabbit anti-goat antibody labeled with horseradish peroxidase (RalphaG-HRP). The effectiveness of the immobilization process was examined using tetramethylbenzidine (TMB), which oxidizes in the presence of HRP to form a visible precipitate. Optical evaluation of the TMB precipitate was used to assess the precision of the features in the inkjet-printed pattern as well as antibody functionality following inkjet printing. Uniform patterns that contained functional antibodies were fabricated using the piezoelectric inkjet printer. These results suggest that piezoelectric inkjet printing may be used to fabricate low-cost disposable immunoassays for biotechnology and healthcare applications.

  13. Electrospun nylon 6/zinc doped hydroxyapatite membrane for protein separation: Mechanism of fouling and blocking model.

    PubMed

    Esfahani, Hamid; Prabhakaran, Molamma P; Salahi, Esmaeil; Tayebifard, Ali; Rahimipour, Mohamad Reza; Keyanpour-Rad, Mansour; Ramakrishna, Seeram

    2016-02-01

    Development of composite nanofibrous membrane via electrospinning a polymer with ceramic nanoparticles (NPs) for application in protein separation systems is explored during this study. Positively charged zinc doped hydroxyapatite (xZH) NPs were prepared in three different compositions via chemical precipitation method. Herein, we created a positively charged surface containing nanoparticles on electrospun Nylon-6 nanofibers (NFs) to improve the separation and selectivity properties for adsorption of negatively charged protein, namely bovine serum albumin (BSA). The decline in permeate flux was analyzed using the framework of classical blocking models and fitting, demonstrated that the transition of fouling mechanisms was dominated during the filtration process. The standard blocking model provided the best fit of the experimental results during the mid-filtration period. The membrane decorated by NPs containing 4at.% zinc cations not only provided maximum BSA separation but also capable of separating higher amounts of BSA molecules (even after 1h filtration) than the pure Nylon membrane. Protein separation was achieved through this membrane with the incorporation of NPs that had high zeta potential (+5.9±0.2mV) and lower particle area (22,155nm(2)). The developed membrane has great potential to act as a high efficiency membrane for capturing BSA. PMID:26652392

  14. Atrazine adsorption removal with nylon6/polypyrrole core-shell nanofibers mat: possible mechanism and characteristics

    NASA Astrophysics Data System (ADS)

    Yang, Bi-Yi; Cao, Yang; Qi, Fei-Fei; Li, Xiao-Qing; Xu, Qian

    2015-05-01

    A functionalized nylon6/polypyrrole core-shell nanofibers mat (PA6/PPy NFM) was prepared via situ polymerization on nylon6 electrospun nanofibers mat (PA6 NFM) template and used as an adsorbent to remove atrazine from aqueous solutions. The core-shell structure of PA6/PPy NFM can be clearly proved under scanning electron microscope (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). The effects of initial solution pH and ionic strength, as well as the comparison of the adsorption capacity of functionalized (PA6/PPy NFM) and non-functionalized (PA6 NFM) adsorbent, were examined to reveal the possible adsorption mechanism. The results indicated that π-π interaction and electrostatic interaction should play a key role in the adsorption process. The kinetics and thermodynamics studies also further elucidated the detailed adsorption characteristics of atrazine removal by PA6/PPy NFM. The adsorption of atrazine could be well described by the pseudo-second-order equation. The adsorption equilibrium data was well fitted with the Freundlich isotherm model with a maximum adsorption capacity value of 14.8 mg/g. In addition, the increase of adsorption rate caused by a temperature increase could be felicitously explained by the endothermic reaction. The desorption results showed that the adsorption capacity remained almost unchanged after six adsorption/desorption cycles. These results suggest that PA6/PPy NFM could be employed as an efficient adsorbent for removing atrazine from contaminated water sources.

  15. Barbed versus conventional 2-layer continuous running sutures for laparoscopic vaginal cuff closure.

    PubMed

    Kim, Jin Hwi; Byun, Seung Won; Song, Jae Yeon; Kim, Yeon Hee; Lee, Hee Joong; Park, Tae Chul; Lee, Keun Ho; Hur, Soo Young; Park, Jong Sup; Lee, Sung Jong

    2016-09-01

    We compared results using unidirectional barbed sutures and conventional sutures for vaginal cuff closure during total laparoscopic hysterectomy (TLH).The electronic medical records and surgical videos of 170 patients who underwent TLH between January 2013 and March 2015 at Uijeong-bu St. Mary's Hospital of Catholic University of Korea were reviewed. Vaginal cuffs were closed using the 2-layer continuous running technique with unidirectional barbed sutures (V-Loc; Covidien, Mansfield, MA) in 64 patients and with polycolic acid Vicryl; Ethicon, Somerville, NJ sutures in 106 patients. Procedure time, clinical characteristics, and postoperative complications were compared between the 2 study groups. There were no differences in clinical characteristics (age, body mass index, and demographic data) between groups. The mean suturing time was significantly reduced in the barbed group (7.2 vs 12.2 minutes; P < 0.001), although the mean number of stitches was greater than in the Vicryl group (14.1 vs 12.3, P < 0.001). Perioperative complications, including episodes of vaginal bleeding, vaginal cuff cellulitis, and postoperative fever, did not differ between groups. There were no instances of vaginal cuff dehiscence in either group. Unidirectional barbed sutures can be used safely to reduce procedure time and surgical difficulty relative to conventional sutures in laparoscopic vaginal cuff closure. PMID:27684850

  16. Enhanced Zone II Flexor Tendon Repair through a New Half Hitch Loop Suture Configuration

    PubMed Central

    Thomopoulos, Stavros; Gelberman, Richard H.

    2016-01-01

    This study evaluated the impact of a new half hitch loop suture configuration on flexor tendon repair mechanics. Cadaver canine flexor digitorum profundus tendons were repaired with 4- or 8-strands, 4–0 or 3–0 suture, with and without half hitch loops. An additional group underwent repair with half hitch loops but without the terminal knot. Half hitch loops improved the strength of 8-strand repairs by 21% when 4–0, and 33% when 3–0 suture was used, and caused a shift in failure mode from suture pullout to suture breakage. 8-strand repairs with half hitch loops but without a terminal knot produced equivalent mechanical properties to those without half hitch loops but with a terminal knot. 4-strand repairs were limited by the strength of the suture in all groups and, as a result, the presence of half hitch loops did not alter the mechanical properties. Overall, half hitch loops improved repair mechanics, allowing failure strength to reach the full capability of suture strength. Improving the mechanical properties of flexor tendon repair with half hitch loops has the potential to reduce the postoperative risk of gap formation and catastrophic rupture in the early postoperative period. PMID:27101409

  17. Development of silver nano-coatings on silk sutures as a novel approach against surgical infections.

    PubMed

    De Simone, S; Gallo, A L; Paladini, F; Sannino, A; Pollini, M

    2014-09-01

    The infections give rise to a range of clinical problems and prolong hospitalization with increased healthcare costs. Moreover, persistent infections exasperate the problem of antibiotic resistance. The aim of this study was the development of effective and low-cost antibacterial silver coatings on surgical sutures by adopting an innovative photochemical deposition process to prevent early contamination of surgical wounds. The silver deposition technology adopted in this work is an innovative process based on the in situ photoreduction of a silver solution. The samples were dipped in the silver solution and then exposed to UV radiation in order to induce the synthesis of silver clusters on the surface of the suture. The homogeneous distribution of silver particles on the surface and on the cross-section of the treated sutures was demonstrated. All the antibacterial studies clearly demonstrated that the use of novel silver treated sutures could represent clinical advantages in terms of the prevention of surgical infections against bacterial colonization. The silver coating deposited on the sutures demonstrated no cytotoxic effect on a selected cell population. The results obtained suggested that the antibacterial silver-coated sutures developed in this work could represent an interesting alternative to conventional sutures, with evident advantages in terms of prevention of the surgical infections and on the health costs. In addiction, very low concentrations of silver significantly inhibited the microbial load, without affecting the cell viability. PMID:24997984

  18. The role of graft materials in suture augmentation for tendon repairs and reattachment.

    PubMed

    Kummer, Frederick J; Iesaka, Kazuho

    2005-08-01

    Various biomaterials have been used to augment sutures for the repair and reattachment of tendons. This study examined four different graft materials in a simple and reproducible model using chicken Achilles tendons to determine the strength and mechanism of suture reinforcement of tendon repairs. The graft materials tested were Gore-Tex(R) Soft Tissue Patch, Graftjacket, bovine pericardium, and an experimental graft material from Xylos Corporation. Testing was performed in shear to simulate forces on a torn tendon repair and pull-off to simulate those on a tendon reattachment to bone. Compared to unaugmented suture, grafts increased suture fixation strength from 10% to 60% in shear and from 0% to 36% in pull-off with the bovine pericardium graft, providing significant improvement in both tests. In no cases (even unaugmented) did the suture pull directly through the tendon, but instead sliced along it, demonstrating that the interface between the suture and the tendon determines fixation strength. Grafts function by increasing the area, friction, and nature of this interface, not by acting as a barrier for suture pull-through. PMID:15981174

  19. FGFR2c-mediated ERK-MAPK activity regulates coronal suture development.

    PubMed

    Pfaff, Miles J; Xue, Ke; Li, Li; Horowitz, Mark C; Steinbacher, Derek M; Eswarakumar, Jacob V P

    2016-07-15

    Fibroblast growth factor receptor 2 (FGFR2) signaling is critical for proper craniofacial development. A gain-of-function mutation in the 2c splice variant of the receptor's gene is associated with Crouzon syndrome, which is characterized by craniosynostosis, the premature fusion of one or more of the cranial vault sutures, leading to craniofacial maldevelopment. Insight into the molecular mechanism of craniosynostosis has identified the ERK-MAPK signaling cascade as a critical regulator of suture patency. The aim of this study is to investigate the role of FGFR2c-induced ERK-MAPK activation in the regulation of coronal suture development. Loss-of-function and gain-of-function Fgfr2c mutant mice have overlapping phenotypes, including coronal synostosis and craniofacial dysmorphia. In vivo analysis of coronal sutures in loss-of-function and gain-of-function models demonstrated fundamentally different pathogenesis underlying coronal suture synostosis. Calvarial osteoblasts from gain-of-function mice demonstrated enhanced osteoblastic function and maturation with concomitant increase in ERK-MAPK activation. In vitro inhibition with the ERK protein inhibitor U0126 mitigated ERK protein activation levels with a concomitant reduction in alkaline phosphatase activity. This study identifies FGFR2c-mediated ERK-MAPK signaling as a key mediator of craniofacial growth and coronal suture development. Furthermore, our results solve the apparent paradox between loss-of-function and gain-of-function FGFR2c mutants with respect to coronal suture synostosis. PMID:27034231

  20. New Method of Age Estimation from Maxillary Sutures Closure in a Thai Population.

    PubMed

    Sinthubua, A; Theera-Umpon, N; Auephanwiriyakul, S; Ruengdit, S; Das, S; Mahakkanukrauh, P

    2016-01-01

    Age estimation is one of the major components of forensic identification. Cranial suture closure has long been used as indicator for age estimation. Maxillary sutures have been less studied for estimation of age at death because they vary in their timing of closure with age. The purpose of this study was to estimate age by examining 190 Thai skulls with age ranging between 15-93 years from Forensic Osteology Research Center, Faculty of Medicine, and Chiang Mai University. Four parts of maxillary suture (incisive, anterior, transverse, and posterior sutures) were investigated the suture obliteration of each suture by computerizing from photograph. The suture were measured by pixel counting.The prediction model which based on the support vector machine (SVM) for regression or support vector regression (SVR) was utilized for data analysis. The results showed high correlation (R2 = 0.9086) between the predicted age and actual age. Plot between actual age group and predicted age in seven groups also revealed high correlation (R2 = 0.9434). These can be implied that we are able to use this SVR model to predict age at death using maxillary suture information.The interesting issue is to further apply this model in more cases to ensure the generalization of the finding. This study is the first attempt to estimate age at death using a new method based on novel analysis which considers a characteristic of relationship between maxillary suture closures with age that are not in linear form. The present study may contribute as a basis knowledge and method for further study of age estimation in archaeological and forensic anthropological contexts, especially when only skull or base of skull are found. PMID:27212570

  1. A miniature tension sensor to measure surgical suture tension of deformable musculoskeletal tissues during joint motion.

    PubMed

    Kiriyama, Yoshimori; Matsumoto, Hideo; Toyama, Yoshiaki; Nagura, Takeo

    2014-02-01

    The aim of this study was to develop a new suture tension sensor for musculoskeletal soft tissue that shows deformation or movements. The suture tension sensor was 10 mm in size, which was small enough to avoid conflicting with the adjacent sensor. Furthermore, the sensor had good linearity up to a tension of 50 N, which is equivalent to the breaking strength of a size 1 absorbable suture defined by the United States Pharmacopeia. The design and mechanism were analyzed using a finite element model prior to developing the actual sensor. Based on the analysis, adequate material was selected, and the output linearity was confirmed and compared with the simulated result. To evaluate practical application, the incision of the skin and capsule were sutured during simulated total knee arthroplasty. When conventional surgery and minimally invasive surgery were performed, suture tensions were compared. In minimally invasive surgery, the distal portion of the knee was dissected, and the proximal portion of the knee was dissected additionally in conventional surgery. In the skin suturing, the maximum tension was 4.4 N, and this tension was independent of the sensor location. In contrast, the sensor suturing the capsule in the distal portion had a tension of 4.4 N in minimally invasive surgery, while the proximal sensor had a tension of 44 N in conventional surgery. The suture tensions increased nonlinearly and were dependent on the knee flexion angle. Furthermore, the tension changes showed hysteresis. This miniature tension sensor may help establish the optimal suturing method with adequate tension to ensure wound healing and early recovery.

  2. Triclosan-coated sutures and sternal wound infections: a prospective randomized clinical trial.

    PubMed

    Steingrimsson, S; Thimour-Bergström, L; Roman-Emanuel, C; Scherstén, H; Friberg, Ö; Gudbjartsson, T; Jeppsson, A

    2015-12-01

    Surgical site infection is a common complication following cardiac surgery. Triclosan-coated sutures have been shown to reduce the rate of infections in various surgical wounds, including wounds after vein harvesting in coronary artery bypass grafting patients. Our purpose was to compare the rate of infections in sternotomy wounds closed with triclosan-coated or conventional sutures. A total of 357 patients that underwent coronary artery bypass grafting were included in a prospective randomized double-blind single-center study. The patients were randomized to closure of the sternal wound with either triclosan-coated sutures (Vicryl Plus and Monocryl Plus, Ethicon, Inc., Somerville, NJ, USA) (n = 179) or identical sutures without triclosan (n = 178). Patients were followed up after 30 days (clinical visit) and 60 days (telephone interview). The primary endpoint was the prevalence of sternal wound infection according to the Centers for Disease Control and Prevention (CDC) criteria. The demographics in both groups were comparable, including age, gender, body mass index, and rate of diabetes and smoking. Sternal wound infection was diagnosed in 43 patients; 23 (12.8%) sutured with triclosan-coated sutures compared to 20 (11.2%) sutured without triclosan (p = 0.640). Most infections were superficial (n = 36, 10.1%), while 7 (2.0%) were deep sternal wound infections. There were 16 positive cultures in the triclosan group and 17 in the non-coated suture group (p = 0.842). The most commonly identified main pathogens were Staphylococcus aureus (45.4%) and coagulase-negative staphylococci (36.4%). Skin closure with triclosan-coated sutures did not reduce the rate of sternal wound infection after coronary artery bypass grafting. (clinicaltrials.gov: NCT01212315).

  3. Effects of pressure, oxygen concentration, and forced convection on flame spread rate of Plexiglas, Nylon and Teflon

    NASA Technical Reports Server (NTRS)

    Notardonato, J. J.; Burkhardt, L. A.; Cochran, T. H.

    1974-01-01

    Experiments were conducted in which the burning of cylindrical materials in a flowing oxidant stream was studied. Plexiglas, Nylon, and Teflon fuel specimens were oriented such that the flames spread along the surface in a direction opposed to flowing gas. Correlations of flame spread rate were obtained that were power law relations in terms of pressure, oxygen concentration, and gas velocity.

  4. The Cyclohexanol Cycle and Synthesis of Nylon 6,6: Green Chemistry in the Undergraduate Organic Laboratory

    ERIC Educational Resources Information Center

    Dintzner, Matthew R.; Kinzie, Charles R.; Pulkrabek, Kimberly; Arena, Anthony F.

    2012-01-01

    A one-term synthesis project that incorporates many of the principles of green chemistry is presented for the undergraduate organic laboratory. In this multistep scheme of reactions, students react, recycle, and ultimately convert cyclohexanol to nylon 6,6. The individual reactions in the project employ environmentally friendly methodologies, and…

  5. The effects of the conditions of char formation on the physical properties of charred phenolic-nylon

    NASA Technical Reports Server (NTRS)

    Smyly, E. D.; Pears, C. D.

    1972-01-01

    A study was made of the effects of the conditions of char formation on the physical properties of charred phenolic nylon of 0.577 gm/cu cm density. It was found that the thermal conductivity and several of the monitors correlate well with degradation conditions. The monitors included electrical resistivity, sonic velocity, porosity, lattice spacing and crystallite size.

  6. Bioremediation of epsilon-caprolactam from nylon-6 waste water by use of Pseudomonas aeruginosa MCM B-407.

    PubMed

    Kulkarni, R S; Kanekar, P P

    1998-09-01

    Nylon-6, a man-made polymer that finds its application in the manufacture of car tires, ropes, fabrics, automobile parts etc., is manufactured with epsilon-caprolactam. Waste water generated during production of nylon-6 contains the unreacted monomer. Owing to the polluting and toxic nature of epsilon-caprolactam, its removal from waste streams is necessary. Pseudomonas aeruginosa MCM B-407 was isolated from activated sludge used to treat waste from a factory producing nylon-6. This organism was able to remove epsilon-caprolactam with simultaneous reduction in chemical oxygen demand (COD). The degradation of epsilon-caprolactam in waste water was found to be optimal over a wide range of pH from 5.0 to 9.0, temperature of 30 degrees C, and under shake or aerated conditions, with an inoculum density of 10(5) cells/ml and with an incubation period of 24 - 48 h. Thus, Pseudomonas aeruginosa MCM B-407 isolated from the activated sludge exposed to epsilon-caprolactam may play an important role in the bioremediation of epsilon-caprolactam from the waste waters of industries manufacturing nylon-6.

  7. A Medial Meniscal Root Pullout Repair With the Use of a Tibial Tunnel Suturing Technique.

    PubMed

    Apivatgaroon, Adinun; Chernchujit, Bancha

    2016-06-01

    A meniscal root tear is one of the common knee injuries that can lead to degenerative changes in the knee joint. Meniscal root repairs can restore proper biomechanics of the knee joint. We have developed a suturing technique that uses a tibial tunnel for a pullout suture medial meniscal root repair. This is a straightforward technique that helps to promote simple suturing of the medial meniscal root, avoid iatrogenic injuries to the articular cartilage, and produce an additional working portal during a meniscal root repair. PMID:27656383

  8. Data on the growth of ZnO nanorods on Nylon 6 and photocatalytic activity.

    PubMed

    Ummartyotin, S; Tangnorawich, B

    2016-09-01

    ZnO was successfully synthesized by a conventional synthetic route using zinc nitrate as a source for ZnO formation. X-ray diffraction and thermogravimetric analysis revealed a crystal size of 66 nm of ZnO and a thermal stability of 500 °C. A small amount of ZnO particles was employed as the source for ZnO-rod growth on nylon 6 surfaces. Scanning electron microscope images were taken to evaluate the morphological properties of ZnO, which presented as a hexagonal needle-like shape. Preliminary evaluation of photocatalytic activity was performed through measurement of the degradation of methylene blue solution over 4 h. PMID:27437437

  9. Nylon 6.6 accelerated aging studies : thermal-oxidative degradation and its interaction with hydrolysis.

    SciTech Connect

    Bernstein, Robert; Derzon, Dora Kay; Gillen, Kenneth T.

    2004-06-01

    Accelerated aging of Nylon 6.6 fibers used in parachutes has been conducted by following the tensile strength loss under both thermal-oxidative and 100% relative humidity conditions. Thermal-oxidative studies (air circulating ovens) were performed for time periods of weeks to years at temperatures ranging from 37 C to 138 C. Accelerated aging humidity experiments (100% RH) were performed under both an argon atmosphere to examine the 'pure' hydrolysis pathway, and under an oxygen atmosphere (oxygen partial pressure close to that occurring in air) to mimic true aging conditions. As expected the results indicated that degradation caused by humidity is much more important than thermal-oxidative degradation. Surprisingly when both oxygen and humidity were present the rate of degradation was dramatically enhanced relative to humidity aging in the absence of oxygen. This significant and previously unknown phenomena underscores the importance of careful accelerated aging that truly mimics real world storage conditions.

  10. Physicochemical characterization of chitosan/nylon6/polyurethane foam chemically cross-linked ternary blends

    NASA Astrophysics Data System (ADS)

    Jayakumar, S.; Sudha, P. N.

    2013-03-01

    Chitosan/nylon6/polyurethane foam (CS/Ny6/PUF) ternary blend was prepared and chemically cross-linked with glutaraldehyde. Structural, thermal and morphological studies were performed for the prepared ternary blends. Characterizations of the ternary blends were investigated by Fourier transform infrared spectroscopy (FTIR), thermo gravimetric analysis (TGA), differential scanning calorimetry (DSC), X-ray diffraction (XRD) and scanning electron microscope (SEM). The FTIR results showed that the strong intermolecular hydrogen bonds took place between CS, Ny6 and PUF. TGA and DSC studies reveal that the thermal stability of the blend is enhanced by glutaraldehyde as crosslinking agent. Results of XRD indicated that the relative crystalline of pure CS film was reduced when the polymeric network was reticulated by glutaraldehyde. Finally, the results of scanning electron microscopy (SEM) indicated that the morphology of the blend is rough and heterogeneous, further it confirms the interaction between the functional groups of the blend components.

  11. Cyclic fatigue behaviour of fibre reinforced rubber-toughened nylon composite materials

    NASA Astrophysics Data System (ADS)

    Pinot, L.; Gomina, M.; Jernot, J.-P.; Moreau, R.; Nakache, E.

    2005-03-01

    The effects of the amount of rubber, the concentration of fibres and the state of the fibre/matrix interface upon the mechanical behaviour of glass fibre/rubber-toughened nylon ternary blends are checked. First, monotonic tensile tests were carried out on different intermediate materials and then on the ternary blends to derive the stress-strain curves and document the damage mechanisms. Cyclic fatigue tests were implemented on tensile specimens and the results were analysed in terms of the reduction of the Young's modulus, the increase of the hysteresis energy rate in the stress-strain diagram and the temperature rise. These findings were correlated to fractographic observations to assess the role of the different constituents.

  12. Analysis of Glass-Filled Nylon in Laser Powder Bed Fusion Additive Manufacturing

    NASA Astrophysics Data System (ADS)

    Slotwinski, John; LaBarre, Erin; Forrest, Ryan; Crane, Emily

    2016-03-01

    At the Johns Hopkins University Applied Physics Laboratory (APL), glass bead-filled polyamide (a.k.a. nylon) (GFN) is being used frequently for functional parts and systems, built using a laser-based powder bed fusion (PBF) additive manufacturing (AM) system. Since these parts have performance requirements, it is important to understand the mechanical properties of the additively-made GFN as a function of build orientation and build parameters. In addition, the performance of the AM system used to manufacture these parts must be evaluated in order to understand its capabilities, especially in order to determine the dimensional precision and repeatability of features built with this system. This paper summarizes recent APL efforts to characterize the GFN powder, the mechanical properties of parts made with GFN, and the performance of the laser PBF machine while running GFN using an AM test artifact.

  13. Molecular self-assembly of nylon-12 nanorods cylindrically confined to nanoporous alumina

    PubMed Central

    Cao, Yan; Wu, Hui; Higaki, Yuji; Jinnai, Hiroshi; Takahara, Atsushi

    2014-01-01

    Molecular self-assembly of nylon-12 rods in self-organized nanoporous alumina cylinders with two different diameters (65 and 300 nm) is studied with transmission electron microscopy (TEM) and wide-angle X-ray diffraction (WAXD) in symmetrical reflection mode. In a rod with a 300 nm diameter, the tendency of the hydrogen-bonding direction of a γ-form crystal parallel to the long axis of the rod is not clear because of weak two-dimensional confinement. In a rod with a diameter of 65 nm, the tendency of the hydrogen-bonding direction of a γ-form crystal parallel to the long axis of the rod is more distinct because of strong two-dimensional confinement. For the first time, selected-area electron diffraction (SAED) is applied in a transmission electron microscope to a polymer nanorod in order to determine the hydrogen-bond sheet and lamellar orientations. Results of TEM–SAED and WAXD showed that the crystals within the rod possess the γ-form of nylon-12 and that the b axis (stem axis) of the γ-form crystals is perpendicular to the long axis of the rod. These results revealed that only lamellae with 〈h0l〉 directions are able to grow inside the nanopores and the growth of lamellae with 〈hkl〉 (k ≠ 0) directions is stopped owing to impingements against the cylinder walls. The dominant crystal growth direction of the 65 nm rod in stronger two-dimensional confinement is in between the [−201] and [001] directions due to the development of a hydrogen-bonded sheet restricted along the long axis of the rod. PMID:25485124

  14. Glottal configuration, acoustic, and aerodynamic changes induced by variation in suture direction in arytenoid adduction procedures.

    PubMed

    Inagi, Katsuhide; Connor, Nadine P; Suzuki, Tatsutoshi; Ford, Charles N; Bless, Diane M; Nakajima, Masami

    2002-10-01

    Arytenoid adduction is a phonosurgical procedure in which the arytenoid cartilages are approximated to reduce posterior glottal gap size and improve voice. Voice outcomes following arytenoid adduction are not always optimal. The goal of this study was to systematically vary suture direction and force of pull on the arytenoid cartilages in a human excised laryngeal model to determine the optimal combination of factors for reducing glottal gap and improving voice. Several factors demonstrated significant effects. Changes in suture direction and force of pull affected glottal configuration in both the horizontal and vertical planes. Increased force of pull on the muscular process resulted in increased adduction of the vocal process for all suture directions. Changes in suture direction and force of pull also affected acoustic and aerodynamic measures of induced voice. Therefore, voice outcomes can be optimized with arytenoid adduction if the vocal fold plane is accurately adjusted.

  15. Bilateral squamosal suture synostosis: A rare form of isolated craniosynostosis in Crouzon syndrome.

    PubMed

    Tandon, Yasmeen K; Rubin, Michael; Kahlifa, Mohamed; Doumit, Gaby; Naffaa, Lena

    2014-07-28

    Craniosynostosis is a pathologic condition which is characterized by the premature fusion of cranial sutures. It may occur alone or in association with other anomalies making up various syndromes. Crouzon syndrome is the most common craniosynostosis syndrome. Bicoronal sutures fusion is most commonly involved in Crouzon syndrome. There have only been a handful of cases of squamosal suture synostosis described in the surgery literature with the few ones described in Crouzon syndrome associated with other types of craniosynostosis. To the best of our knowledge, we are presenting the first case of isolated bilateral squamosal suture synostosis in a patient with Crouzon syndrome in a radiology journal with emphasis on its radiological appearance. PMID:25071892

  16. Stem cells of the suture mesenchyme in craniofacial bone development, repair and regeneration

    PubMed Central

    Maruyama, Takamitsu; Jeong, Jaeim; Sheu, Tzong-Jen; Hsu, Wei

    2016-01-01

    The suture mesenchyme serves as a growth centre for calvarial morphogenesis and has been postulated to act as the niche for skeletal stem cells. Aberrant gene regulation causes suture dysmorphogenesis resulting in craniosynostosis, one of the most common craniofacial deformities. Owing to various limitations, especially the lack of suture stem cell isolation, reconstruction of large craniofacial bone defects remains highly challenging. Here we provide the first evidence for an Axin2-expressing stem cell population with long-term self-renewing, clonal expanding and differentiating abilities during calvarial development and homeostastic maintenance. These cells, which reside in the suture midline, contribute directly to injury repair and skeletal regeneration in a cell autonomous fashion. Our findings demonstrate their true identity as skeletal stem cells with innate capacities to replace the damaged skeleton in cell-based therapy, and permit further elucidation of the stem cell-mediated craniofacial skeletogenesis, leading to revealing the complex nature of congenital disease and regenerative medicine. PMID:26830436

  17. The suture provides a niche for mesenchymal stem cells of craniofacial bones

    PubMed Central

    Zhao, Hu; Feng, Jifan; Ho, Thach-Vu; Grimes, Weston; Urata, Mark; Chai, Yang

    2015-01-01

    Bone tissue undergoes constant turnover supported by stem cells. Recent studies showed that perivascular mesenchymal stem cells (MSCs) contribute to the turnover of long bones. Craniofacial bones are flat bones derived from a different embryonic origin than the long bones. The identity and regulating niche for craniofacial bone MSCs remain unknown. Here, we identify Gli1+ cells within the suture mesenchyme as the major MSC population for craniofacial bones. They are not associated with vasculature, give rise to all craniofacial bones in the adult and are activated during injury repair. Gli1+ cells are typical MSCs in vitro. Ablation of Gli1+ cells leads to craniosynostosis and arrest of skull growth, indicating these cells are an indispensible stem cell population. Twist1+/− mice with craniosynostosis show reduced Gli1+ MSCs in sutures, suggesting that craniosynostosis may result from diminished suture stem cells. Our study indicates that craniofacial sutures provide a unique niche for MSCs for craniofacial bone homeostasis and repair. PMID:25799059

  18. Cutaneous fistula from the gastric remnant resulting from a chronic suture-associated biofilm infection.

    PubMed

    Kathju, Sandeep; Lasko, Leslie-Ann; Nistico, Laura; Colella, Joseph J; Stoodley, Paul

    2010-02-01

    A 53-year-old woman developed three chronic draining sinuses after Roux-en-Y gastric bypass; these persisted for almost 1 year despite antibiotics and local wound care. At approximately 1 year post-operatively, the drainage from the most superior sinus increased significantly and assumed a greenish hue, prompting concerns for gastrocutaneous fistula despite negative radiologic evaluation. At surgery, the patient was found to have a retained permanent multifilament suture at the base of each sinus, with associated inflammatory and fibrous tissue and a "slimy" matrix. Confocal laser scanning microscopy of both the explanted sutures and investing soft tissue revealed extensive bacterial biofilm formation. Also at surgery, a frank fistulous track was noted communicating the most superior suture/sinus to the gastric remnant, necessitating laparotomy and remnant gastrectomy in addition to removal of the foreign bodies (sutures) and concomitant panniculectomy. The patient has subsequently been free of complaint or finding for over 3 years.

  19. Local tissue reactions after nerve repair with ethyl-cyanoacrylate compared with epineural sutures.

    PubMed

    Landegren, Thomas; Risling, Mårten; Persson, Jonas K E

    2007-01-01

    Anastomosis of a nerve with cyanoacrylate following a lesion has previously been shown to indicate morphological and functional recovery to an extent comparable to that of conventional epineural sutures. In this study we examined the local tissue reactions after transection and repair of rat sciatic nerve, and compared sutures with a synthetic ethyl-cyanoacrylate adhesive. Many ED-1-immunoreactive macrophages were found accumulating on either side of the repair site whereas neurofilament labelling was less pronounced distal to the repair site seven days after reparation with cyanoacrylate compared with sutures. After six months, when reinnervation was completed, the difference in ED-1-immunoreactivity was still present but to a less extent. These results indicate that ethyl-cyanoacrylate seems to induce an increased inflammatory reaction, which may lead to accelerated Wallerian degeneration, and could therefore have benefits over conventional sutures for reconstruction of peripheral nerves.

  20. Deformation and sedimentation along a developing terrane suture: Eastern Sunda forearc, Indonesia

    SciTech Connect

    Reed, D.L.; Silver, E.A.; Prasetyo, H.; Meyer, A.W.

    1986-12-01

    The collision of the eastern Sunda arc with northwest Australia has resulted in the development of a suture between the Sumba ridge and Sawu-Timor terranes along a zone of intraforearc convergence. The developing suture varies from the low-angle Sawu thrust, with attendant mud diapirs in the Sumba basin, to high-angle reverse faults near a basement high of the underthrust Sumba ridge terrane. Bottom currents, associated with the flow of Pacific Ocean deep water into the Indian Ocean, have eroded the terranes and subsequently deposited the detritus in an assemblage of contourites along the suture. This study reveals the high structural variability of a terrane suture and the oceanographic influence on the deposition of overlap assemblages.

  1. Specialty polymeric membranes. 8: Separation of benzene from benzene/cyclohexane mixtures with nylon 6-graft-poly(butyl methacrylate) membranes

    SciTech Connect

    Yoshikawa, Masakazu; Tsubouchi, Keisuke; Kitao, Toshio

    1999-02-01

    A novel pervaporation membrane was prepared by radical graft polymerization of butyl methacrylate onto nylon 6. The permselectivity toward benzene was increased by the introduction of poly(butyl methacrylate) onto a nylon 6 membrane. From pervaporation and sorption experiments, it was shown that the introduction of poly(butyl methacrylate) onto a nylon 6 membrane leads to the enhancement of permselectivity toward benzene. The solubility data for benzene were described by a combination of simple sorption and specific sorption, while cyclohexane solubility was described by simple sorption.

  2. Material properties of human infant skull and suture at high rates.

    PubMed

    Coats, Brittany; Margulies, Susan S

    2006-08-01

    Clinicians are often faced with the challenging task of distinguishing between accidental and inflicted pediatric head trauma. There is currently a disparity in the anecdotal case study literature as to what kinds of injuries can occur in children from low height falls. There is also a paucity of material property data for pediatric skull and suture at rates similar to those expected in low height falls. We tested human infant (<1 year old) cranial bone and suture from 23 calveria in three-point bending and tension, respectively, at rates ranging from 1.2-2.8 m/sec. Donor age was found to have the largest influence on the elastic modulus and ultimate stress of cranial bone, with an increase in age increasing both material properties. In adults, cranial bone and suture have similar properties and the adult calveria deforms very little prior to fracture. In contrast, pediatric cranial bone is 35 times stiffer than pediatric cranial suture. In addition, pediatric cranial suture deforms 30 times more before failure than pediatric cranial bone and 243 times more than adult cranial bone. The large strains in the pediatric bone and suture result in a skullcase that can undergo dramatic shape changes before fracture, potentially causing substantial deformation in the brain. The sizeable difference between pediatric bone and suture material properties also underscores the crucial role that sutures play in the unique response of the pediatric head to impact in low height falls. These data provide necessary information to enhance our understanding of mechanisms of head injury in young children.

  3. Endoscopic removal of intravesical polypropylene suture with plasmakinetic resection after abdominal hysterectomy

    PubMed Central

    Küçükdurmaz, Faruk; Can, Selman; Barut, Osman

    2014-01-01

    INTRODUCTION Intravesical foreign substances such as mesh or suture are among the rare reasons of recurrent urinary tract infections. Anti-incontinence and prolapsus procedures are associated with mesh/suture extrusion into the bladder, however, this complication is uncommon with abdominal hysterectomy. PRESENTATION OF CASE A 61-year-old female, obese patient admitted to our clinic with recurrent urinary tract infections and voiding symptoms which were worsened after abdominal hysterectomy. Radiological evaluation revealed an intravesical foreign material within the bladder. The cytoscopy was performed and a polypropylene suture which was inserted from dome, passed through the base and exited from the dome of bladder during abdominal hysterectomy. Transurethral plasmakinetic resection of superficial layer of urothelium between suture entrance and exit sites was performed and suture was removed from the bladder. DISCUSSION Urogynecological procedures are associated with the increased risk of urethral or ureteral injury, intravesical mesh or suture erosion and fistulae formation. Many different techniques including open, laparoscopic and transvaginal approaches were described for the removal of intravesical mesh/suture extrusion in the literature. Transurethral approach with its minimally invasive and safe nature was used to remove suture in this patient. This technique with the use of plasmakinetic energy has the advantage of decreased risk of bleeding and urothelial injury when compared to monopolar cautery. It also avoids the need for open or extensive surgery which may have a high rate of complications. CONCLUSION Transurethral resection is the treatment of choice for the removal of intravesical foreign substances. Use of plasmakinetic energy will decrease the risk of complications and avoid the need for open interventions. PMID:25437667

  4. [Iris suture fixation of posterior-chamber elastic intraocular lens in ligament apparatus laxity].

    PubMed

    Pashtaev, N P; Bat'kov, E N; Zotov, V V

    2010-01-01

    An original MIOL-23 multifocal elastic intraocular lens (IOL) was used to operate 5 eyes with acquired lens dislocation and traumatic cataract. By making self-sealing tunnel incision, ILO was implanted into the capsular sac and sutured to the iris. MIOL-23 implantation caused an increase in mean visual acuity. The IOL took up a correct position. Elastic IOL implantation with iris suture fixation is an efficient and safe mode of additional ILO support. PMID:20645577

  5. A single centre comparative study of laparoscopic mesh rectopexy versus suture rectopexy

    PubMed Central

    Sahoo, Manash Ranjan; Thimmegowda, Anil Kumar; Gowda, Manoj S

    2014-01-01

    AIM: The aim of our study is to compare the results of laparoscopic mesh vs. suture rectopexy. MATERIALS AND METHODS: In this retrospective study, 70 patients including both male and female of age ranging between 20 years and 65 years (mean 42.5 yrs) were subjected to laparoscopic rectopexy during the period between March 2007 and June 2012, of which 38 patients underwent laparoscopic mesh rectopexy and 32 patients laparoscopic suture rectopexy. These patients were followed up for a mean period of 12 months assessing first bowel movement, hospital stay, duration of surgery, faecal incontinence, constipation, recurrence and morbidity. RESULTS: Duration of surgery was 100.8 ± 12.4 minutes in laparoscopic suture rectopexy and 120 ± 10.8 min in laparoscopic mesh rectopexy. Postoperatively, the mean time for the first bowel movement was 38 hrs and 40 hrs, respectively, for suture and mesh rectopexy. Mean hospital stay was five (range: 4-7) days. There was no significant postoperative complication except for one port site infection in mesh rectopexy group. Patients who had varying degree of incontinence preoperatively showed improvement after surgery. Eleven out of 18 (61.1%) patients who underwent laparoscopic suture rectopexy as compared to nine of 19 (47.3%) patients who underwent laparoscopic mesh rectopexy improved as regards constipation after surgery. CONCLUSION: There were no significant difference in both groups who underwent surgery except for patients undergoing suture rectopexy had better symptomatic improvement of continence and constipation. Also, cost of mesh used in laparoscopic mesh rectopexy is absent in lap suture rectopexy group. To conclude that laparoscopic suture rectopexy is a safe and feasible procedure and have comparable results as regards operative time, morbidity, bowel function, cost and recurrence or even slightly better results than mesh rectopexy. PMID:24501504

  6. Identification and dynamics of a cryptic suture zone in tropical rainforest

    PubMed Central

    Moritz, C.; Hoskin, C.J.; MacKenzie, J.B.; Phillips, B.L.; Tonione, M.; Silva, N.; VanDerWal, J.; Williams, S.E.; Graham, C.H.

    2009-01-01

    Suture zones, shared regions of secondary contact between long-isolated lineages, are natural laboratories for studying divergence and speciation. For tropical rainforest, the existence of suture zones and their significance for speciation has been controversial. Using comparative phylogeographic evidence, we locate a morphologically cryptic suture zone in the Australian Wet Tropics rainforest. Fourteen out of 18 contacts involve morphologically cryptic phylogeographic lineages, with mtDNA sequence divergences ranging from 2 to 15 per cent. Contact zones are significantly clustered in a suture zone located between two major Quaternary refugia. Within this area, there is a trend for secondary contacts to occur in regions with low environmental suitability relative to both adjacent refugia and, by inference, the parental lineages. The extent and form of reproductive isolation among interacting lineages varies across species, ranging from random admixture to speciation, in one case via reinforcement. Comparative phylogeographic studies, combined with environmental analysis at a fine-scale and across varying climates, can generate new insights into suture zone formation and to diversification processes in species-rich tropical rainforests. As arenas for evolutionary experimentation, suture zones merit special attention for conservation. PMID:19203915

  7. Cranial Suture Closure in Domestic Dog Breeds and Its Relationships to Skull Morphology.

    PubMed

    Geiger, Madeleine; Haussman, Sinah

    2016-04-01

    Bulldog-type brachycephalic domestic dog breeds are characterized by a relatively short and broad skull with a dorsally rotated rostrum (airorhynchy). Not much is known about the association between a bulldog-type skull conformation and peculiar patterns of suture and synchondrosis closure in domestic dogs. In this study, we aim to explore breed-specific patterns of cranial suture and synchondrosis closure in relation to the prebasial angle (proxy for airorhynchy and thus bulldog-type skull conformation) in domestic dogs. For this purpose, we coded closure of 18 sutures and synchondroses in 26 wolves, that is, the wild ancestor of all domestic dogs, and 134 domestic dogs comprising 11 breeds. Comparisons of the relative amount of closing and closed sutures and synchondroses (closure scores) in adult individuals showed that bulldog-type breeds have significantly higher closure scores than non-bulldog-type breeds and that domestic dogs have significantly higher closure scores than the wolf. We further found that the prebasial angle is significantly positively correlated with the amount of closure of the basispheno-presphenoid synchondrosis and sutures of the nose (premaxillo-nasal and maxillo-nasal) and the palate (premaxillo-maxillary and interpalatine). Our results show that there is a correlation between patterns of suture and synchondrosis closure and skull shape in domestic dogs, although the causal relationships remain elusive. PMID:26995336

  8. Asymmetric six-strand core sutures enhance tendon fatigue strength and the optimal asymmetry.

    PubMed

    Kozono, N; Okada, T; Takeuchi, N; Hanada, M; Shimoto, T; Iwamoto, Y

    2016-10-01

    Under cyclic loading, we recorded the fatigue strength of a six-strand tendon repair with different symmetry in the lengths of suture purchase in two stumps of 120 dental rolls and in 30 porcine tendons. First, the strengths of the repairs with 1, 2, 3, 4 and 5 mm asymmetry were screened using the dental rolls. The asymmetric core suture repairs were then made with a Kessler repair of equal suture purchase (10 mm) in two tendon stumps, and shifting two other Kessler repairs by 1, 3 or 5 mm, respectively, along the longitudinal axis of the tendon in relation to the first (symmetric) Kessler repair. The core repairs with 3 mm or more asymmetry in suture purchases in two tendon ends showed significantly greater fatigue strength and significantly smaller gaps compared with 1 mm asymmetry in core suture repair. Our results support that asymmetric placement of core sutures in two tendon ends favour resisting gapping at the repair site and 3 mm or more asymmetry is needed to produce such beneficial effects.

  9. Closure of round cutaneous defects progressively with the purse string suture technique

    PubMed Central

    Küçükdurmaz, Fatih; Agir, Ismail; Gümüstas, Seyitali; Kivilcim, Hakan; Tetik, Cihangir

    2015-01-01

    Introduction There are many closure techniques available to cutaneous surgeons. One of them is the purse-string suture which is used to provide complete or partial closure of round skin defects. In our animal study; we closed skin defects with using subcuticular purse string suture technique by progressively cinching wound and we aim to more rapidly healing according to secondary healing. Methods After anaesthetize, we created a 4 cm diameter circular full thickness skin defect on dorsal area of rats. In group 1, subcuticular purse string suture was applied by using a nonabsorbable and monofilament suture and a sliding arthroscopic knot was applied to both ends. Arthroscopic suture was shift 1 cm forward every day. In group 2 skin defect was leaved open and daily dressing was made and in both group defect diameters were measured every day and noted. Results The skin defects were closed totally after 15 days in group 1 but in group 2 defects were reduced but still had a mean 1,5-cm diameter sircular defect. Conclusion Closing large circular wound with purse string suture and gradual tightening decreases the healing time and expand the skin tissue without using any tissue expander. PMID:26600915

  10. The Development of the Calvarial Bones and Sutures and the Pathophysiology of Craniosynostosis.

    PubMed

    Ishii, Mamoru; Sun, Jingjing; Ting, Man-Chun; Maxson, Robert E

    2015-01-01

    The skull vault is a complex, exquisitely patterned structure that plays a variety of key roles in vertebrate life, ranging from the acquisition of food to the support of the sense organs for hearing, smell, sight, and taste. During its development, it must meet the dual challenges of protecting the brain and accommodating its growth. The bones and sutures of the skull vault are derived from cranial neural crest and head mesoderm. The frontal and parietal bones develop from osteogenic rudiments in the supraorbital ridge. The coronal suture develops from a group of Shh-responsive cells in the head mesoderm that are collocated, with the osteogenic precursors, in the supraorbital ridge. The osteogenic rudiments and the prospective coronal suture expand apically by cell migration. A number of congenital disorders affect the skull vault. Prominent among these is craniosynostosis, the fusion of the bones at the sutures. Analysis of the pathophysiology underling craniosynostosis has identified a variety of cellular mechanisms, mediated by a range of signaling pathways and effector transcription factors. These cellular mechanisms include loss of boundary integrity, altered sutural cell specification in embryos, and loss of a suture stem cell population in adults. Future work making use of genome-wide transcriptomic approaches will address the deep structure of regulatory interactions and cellular processes that unify these seemingly diverse mechanisms. PMID:26589924

  11. Investigation of the best suture pattern to close a stuffed Christmas turkey.

    PubMed

    Verwilghen, D; Busoni, V; van Galen, G; Wilke, M

    Instructions on how to debone and stuff a turkey are available, but what is the best way to close it up? A randomised trial involving 15 turkeys was performed in order to evaluate skin disruption scores and cosmetic outcomes following the use of different suture patterns. Turkeys were deboned, stuffed and cooked according to guidelines of the US Department of Agriculture Food Safety and Inspection Services. After stuffing, they were randomly assigned to one of five closure groups: simple continuous Lembert; simple continuous Cushing; simple continuous Utrecht; simple continuous; or staples. Turkeys were cooked at 180 °C for two hours ensuring core temperature reached 75 °C. Suture line integrity was evaluated after removal of the sutures and the cosmetic aspect was graded. Before cooking, the Utrecht pattern and skin staples offered the best cosmetic result. After removal of the sutures, the skin remained intact only in the stapled group. All other suture patterns disrupted the skin after removal of the sutures, rendering the turkey less cosmetically appealing for serving. Closure of a stuffed turkey was best performed using skin staples to achieve the best cosmetic results. Using this technique you will be able to impress family and friends at a Christmas dinner, and finally show them your surgical skills.

  12. Fusion Patterns in the Skulls of Modern Archosaurs Reveal That Sutures Are Ambiguous Maturity Indicators for the Dinosauria.

    PubMed

    Bailleul, Alida M; Scannella, John B; Horner, John R; Evans, David C

    2016-01-01

    The sutures of the skulls of vertebrates are generally open early in life and slowly close as maturity is attained. The assumption that all vertebrates follow this pattern of progressive sutural closure has been used to assess maturity in the fossil remains of non-avian dinosaurs. Here, we test this assumption in two members of the Extant Phylogenetic Bracket of the Dinosauria, the emu, Dromaius novaehollandiae and the American alligator, Alligator mississippiensis, by investigating the sequence and timing of sutural fusion in their skulls. As expected, almost all the sutures in the emu skull progressively close (i.e., they get narrower) and then obliterate during ontogeny. However, in the American alligator, only two sutures out of 36 obliterate completely and they do so during embryonic development. Surprisingly, as maturity progresses, many sutures of alligators become wider in large individuals compared to younger, smaller individuals. Histological and histomorphometric analyses on two sutures and one synchondrosis in an ontogenetic series of American alligator confirmed our morphological observations. This pattern of sutural widening might reflect feeding biomechanics and dietary changes through ontogeny. Our findings show that progressive sutural closure is not always observed in extant archosaurs, and therefore suggest that cranial sutural fusion is an ambiguous proxy for assessing maturity in non-avian dinosaurs. PMID:26862766

  13. Fusion Patterns in the Skulls of Modern Archosaurs Reveal That Sutures Are Ambiguous Maturity Indicators for the Dinosauria

    PubMed Central

    Bailleul, Alida M.; Scannella, John B.; Horner, John R.; Evans, David C.

    2016-01-01

    The sutures of the skulls of vertebrates are generally open early in life and slowly close as maturity is attained. The assumption that all vertebrates follow this pattern of progressive sutural closure has been used to assess maturity in the fossil remains of non-avian dinosaurs. Here, we test this assumption in two members of the Extant Phylogenetic Bracket of the Dinosauria, the emu, Dromaius novaehollandiae and the American alligator, Alligator mississippiensis, by investigating the sequence and timing of sutural fusion in their skulls. As expected, almost all the sutures in the emu skull progressively close (i.e., they get narrower) and then obliterate during ontogeny. However, in the American alligator, only two sutures out of 36 obliterate completely and they do so during embryonic development. Surprisingly, as maturity progresses, many sutures of alligators become wider in large individuals compared to younger, smaller individuals. Histological and histomorphometric analyses on two sutures and one synchondrosis in an ontogenetic series of American alligator confirmed our morphological observations. This pattern of sutural widening might reflect feeding biomechanics and dietary changes through ontogeny. Our findings show that progressive sutural closure is not always observed in extant archosaurs, and therefore suggest that cranial sutural fusion is an ambiguous proxy for assessing maturity in non-avian dinosaurs. PMID:26862766

  14. Efficacy of Single-Suture Incision Closures in Tagged Juvenile Chinook Salmon Exposed to Simulated Turbine Passage

    SciTech Connect

    Boyd, James W.; Deters, Katherine A.; Brown, Richard S.; Eppard, M. B.

    2011-09-01

    Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the use of a shorter incision-one that may warrant only a single suture for closure. However, it is not known whether a single suture will sufficiently hold the incision closed when fish are decompressed and when outward pressure is placed on the surgical site during turbine passage through hydroelectric dams. The objective of this study was to evaluate the effectiveness of single-suture incision closures on five response variables in juvenile Chinook salmon Oncorhynchus tshawytscha that were subjected to simulated turbine passage. An acoustic transmitter (0.43 g in air) and a passive integrated transponder tag (0.10 g in air) were implanted in each fish; the 6-mm incisions were closed with either one suture or two sutures. After exposure to simulated turbine passage, none of the fish exhibited expulsion of transmitters. In addition, the percentage of fish with suture tearing, incision tearing, or mortal injury did not differ between treatments. Expulsion of viscera through the incision was higher among fish that received one suture (12%) than among fish that received two sutures (1%). The higher incidence of visceral expulsion through single-suture incisions warrants concern. Consequently, for cases in which tagged juvenile salmonidsmay be exposed to turbine passage, we do not recommend the use of one suture to close 6-mm incisions associated with acoustic transmitter implantation.

  15. Ultrastructure, Histochemistry, and Mineralization Patterns in the Ecdysial Suture of the Blue Crab, Callinectes sapidus

    NASA Astrophysics Data System (ADS)

    Priester, Carolina; Dillaman, Richard M.; Gay, D. Mark

    2005-12-01

    The ecdysial suture is the region of the arthropod exoskeleton that splits to allow the animal to emerge during ecdysis. We examined the morphology and composition of the intermolt and premolt suture of the blue crab using light microscopy and scanning electron microscopy. The suture could not be identified by routine histological techniques; however 3 of 22 fluorescein isothiocyanate-labeled lectins tested (Lens culinaris agglutinin, Vicia faba agglutinin, and Pisum sativum agglutinin) differentiated the suture, binding more intensely to the suture exocuticle and less intensely to the suture endocuticle. Back-scattered electron (BSE) and secondary electron observations of fracture surfaces of intermolt cuticle showed less mineralized regions in the wedge-shaped suture as did BSE analysis of premolt and intermolt resin-embedded cuticle. The prism regions of the suture exocuticle were not calcified. X-ray microanalysis of both the endocuticle and exocuticle demonstrated that the suture was less calcified than the surrounding cuticle with significantly lower magnesium and phosphorus concentrations, potentially making its mineral more soluble. The presence or absence of a glycoprotein in the organic matrix, the extent and composition of the mineral deposited, and the thickness of the cuticle all likely contribute to the suture being removed by molting fluid, thereby ensuring successful ecdysis.

  16. Performance Assessment of Suture Type, Water Temperature, and Surgeon Skill in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters

    SciTech Connect

    Deters, Katherine A.; Brown, Richard S.; Carter, Kathleen M.; Boyd, James W.; Eppard, M. B.; Seaburg, Adam

    2010-05-01

    This study assessed performance of seven suture types in subyearling Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Nonabsorbable (Ethilon) and absorbable (Monocryl) monofilament and nonabsorbable (Nurolon, silk) and absorbable (Vicryl, Vicryl Plus, Vicryl Rapide) braided sutures were used to close incisions in Chinook salmon. Monocryl exhibited greater suture retention than all other suture types 7 d after surgery. Both monofilament suture types were retained better than all braided suture types at 14 d. Incision openness and tag retention did not differ among suture types. Wound inflammation was similar for Ethilon, Monocryl, and Nurolon at 7 d. Wound ulceration was lower for Ethilon, Monocryl, and Nurolon than for all other suture types at 14 d post-surgery. Fish held in 12°C water had more desirable post-surgery healing characteristics (i.e., higher suture and tag retention and lower incision openness, wound inflammation, and ulceration) at 7 and 14 d after surgery than those held in 17°C water. The effect of surgeon was a significant predictor for all response variables at 7 d. This result emphasizes the importance of including surgeon as a variable in telemetry study analyses when multiple surgeons are used. Monocryl performed better with regard to post-surgery healing characteristics in the study fish. The overall results support the conclusion that Monocryl is the best suture material to close incisions created during surgical implantation of acoustic microtransmitters in subyearling Chinook salmon.

  17. Mesoproterozoic suturing of Archean crustal blocks in western peninsular India: Implications for India-Madagascar correlations

    NASA Astrophysics Data System (ADS)

    Ishwar-Kumar, C.; Santosh, M.; Wilde, S. A.; Tsunogae, T.; Itaya, T.; Windley, B. F.; Sajeev, K.

    2016-10-01

    The Kumta and Mercara suture zones welding together Archean crustal blocks in western peninsular India offer critical insights into Precambrian continental juxtapositions and the crustal evolution of eastern Gondwana. Here we present the results from an integrated study of the structure, geology, petrology, mineral chemistry, metamorphic P-T conditions, zircon U-Pb ages and Lu-Hf isotopes of metasedimentary rocks from the two sutures. The dominant rocks in the Kumta suture are greenschist- to amphibolite-facies quartz-phengite schist, garnet-biotite schist, chlorite schist, fuchsite schist and marble. The textural relations, mineral chemistry and thermodynamic modelling of garnet-biotite schist from the Kumta suture indicate peak metamorphic P-T conditions of ca. 11 kbar at 790 °C, with detrital SHRIMP U-Pb zircon ages ranging from 3420 to 2547 Ma, εHf (t) values from - 9.2 to 5.6, and TDMc model ages from 3747 to 2792 Ma. The K-Ar age of phengite from quartz-phengite schist is ca. 1326 Ma and that of biotite from garnet-biotite schist is ca. 1385 Ma, which are interpreted to broadly constrain the timing of metamorphism related to the suturing event. The Mercara suture contains amphibolite- to granulite-facies mylonitic quartzo-feldspathic gneiss, garnet-kyanite-sillimanite gneiss, garnet-biotite-kyanite-gedrite-cordierite gneiss, garnet-biotite-hornblende gneiss, calc-silicate granulite and metagabbro. The textural relations, mineral chemistry and thermodynamic modelling of garnet-biotite-kyanite-gedrite-cordierite gneiss from the Mercara suture indicate peak metamorphic P-T conditions of ca. 13 kbar at 825 °C, followed by isothermal decompression and cooling. For pelitic gneisses from the Mercara suture, LA-ICP-MS U-Pb zircon ages vary from 3249 to 3045 Ma, εHf (t) values range from - 18.9 to 4.2, and TDMc model ages vary from 4094 to 3314 Ma. The lower intercept age of detrital zircons in the pelitic gneisses from the Mercara suture ranges from 1464 to 1106

  18. Electron-Beam Irradiation Effect on Thermal and Mechanical Properties of Nylon-6 Nanocomposite Fibers Infused with Diamond and Diamond Coated Carbon Nanotubes

    NASA Astrophysics Data System (ADS)

    Imam, Muhammad A.; Jeelani, Shaik; Rangari, Vijaya K.; Gome, Michelle G.; Moura, Esperidiana. A. B.

    2016-02-01

    Nylon-6 is an engineering plastic with excellent properties and processability, which are essential in several industrial applications. The addition of filler such as diamond (DN) and diamond coated carbon nanotubes (CNTs) to form molded composites may increase the range of Nylon-6 applications due to the resulting increase in strength. The effects of electron-beam irradiation on these thermoplastic nanocomposites are either increase in the cross-linking or causes chain scission. In this study, DN-coated CNTs were synthesized using the sonochemical technique in the presence of cationic surfactant cetyltrimethyl ammonium bromide (CTAB). The DN-coated CNTs nanoparticles and diamond nanoparticles were then introduced into Nylon-6 polymer through a melt extrusion process to form nanocomposite fibers. They were further tested for their mechanical (Tensile) and thermal properties (thermogravimetric analysis (TGA), differential scanning calorimetry (DSC)). These composites were further exposed to the electron-beam (160kGy, 132kGy and 99kGy) irradiation using a 1.5MeV electron-beam accelerator, at room temperature, in the presence of air and tested for their thermal and mechanical properties. The best ultimate tensile strength was found to be 690MPa and 864MPa irradiated at 132 for DN/CNTs/Nylon-6 and Diamond/Nylon-6 nanocomposite fiber as compared to 346MPa and 321MPa for DN/CNTs/Nylon-6 and Diamond/Nylon-6 nanocomposite fiber without irradiation. The neat Nylon-6 tensile strength was 240MPa. These results are consistent with the activation energy calculated from TGA graphs. DSC analysis result shows that the slight increase in glass transition temperature (Tg) and decrease in melting temperature (Tm) which was expected from high electron-beam radiation dose.

  19. A pilot study evaluating laparoscopic closure of the nephrosplenic space using an endoscopic suturing device in standing horses.

    PubMed

    Bracamonte, José L; Duke-Novakovski, Tanya

    2016-06-01

    This study evaluated the use of an articulating automated suturing device for laparoscopic closure of the nephrosplenic space in standing horses. Closure of the nephrosplenic space was performed in 4 horses using an automated suturing device. Second-look laparoscopy was performed at 5 weeks. A smooth fibrous adhesion formed between the spleen, the perirenal fascia, and the nephrosplenic ligament in 3 of the 4 horses in which the nephrosplenic space was closed using the automated suturing device. In 1 horse, closure of the nephrosplenic space was not possible due to constant breakage of the endoscopic needle. Intra-operative complications encountered with the automated suturing device were tearing of the perirenal fascia, nephrosplenic ligament, and dorsal splenic capsule along with breakage of the needle. The automated suturing device used in this study for laparoscopic closure of the nephrosplenic space resulted in longer surgery times, suffered instrument failures and delivered inadequate suture.

  20. Suture Line Response of End-to-Side Anastomosis: A Stress Concentration Methodology.

    PubMed

    Roussis, P C; Giannakopoulos, A E; Charalambous, H P

    2015-03-01

    End-to-side vascular anastomosis has a considerable complexity regarding the suturing of the juncture line between the artery and the graft. The present study proposes a stress-concentration methodology for the prediction of the stress distribution at the juncture line, aiming to provide generic expressions describing the response of an end-to-side anastomosis. The proposed methodology is based on general results obtained from the analysis of pipe connections, a topic that has been investigated in recent years in the field of offshore structural engineering. A key aspect for implementing the stress-concentration-factor approach is the recognition that the axial load due to pressure and flow dynamics exerted along the graft axis controls the "hot spots" on the juncture line, which in turn affects the mechanical response of the sutures. Several parameters, identified to influence the suture line response, are introduced in closed-form expressions for the suture line response calculations. The obtained results compare favorably with finite element results published in the literature. The proposed model predicts analytically the suture line response of end-to-side anastomosis, while capturing the influence of and interdependence among the problem parameters. Lower values of the graft radius, the distance between sequential stitches, and the intersecting angle between the artery and the graft are some of the key parameters that reduce the suture line response. The findings of this study are broad in scope and potentially applicable to improving the end-to-side anastomosis technique through improved functionality of the sutures and optimal selection of materials and anastomosis angle.

  1. Suture Line Response of End-to-Side Anastomosis: A Stress Concentration Methodology.

    PubMed

    Roussis, P C; Giannakopoulos, A E; Charalambous, H P

    2015-03-01

    End-to-side vascular anastomosis has a considerable complexity regarding the suturing of the juncture line between the artery and the graft. The present study proposes a stress-concentration methodology for the prediction of the stress distribution at the juncture line, aiming to provide generic expressions describing the response of an end-to-side anastomosis. The proposed methodology is based on general results obtained from the analysis of pipe connections, a topic that has been investigated in recent years in the field of offshore structural engineering. A key aspect for implementing the stress-concentration-factor approach is the recognition that the axial load due to pressure and flow dynamics exerted along the graft axis controls the "hot spots" on the juncture line, which in turn affects the mechanical response of the sutures. Several parameters, identified to influence the suture line response, are introduced in closed-form expressions for the suture line response calculations. The obtained results compare favorably with finite element results published in the literature. The proposed model predicts analytically the suture line response of end-to-side anastomosis, while capturing the influence of and interdependence among the problem parameters. Lower values of the graft radius, the distance between sequential stitches, and the intersecting angle between the artery and the graft are some of the key parameters that reduce the suture line response. The findings of this study are broad in scope and potentially applicable to improving the end-to-side anastomosis technique through improved functionality of the sutures and optimal selection of materials and anastomosis angle. PMID:26577101

  2. Acrylic polymer-grafted polypropylene sutures for covalent immobilization or reversible adsorption of vancomycin.

    PubMed

    García-Vargas, M; González-Chomón, C; Magariños, B; Concheiro, A; Alvarez-Lorenzo, C; Bucio, E

    2014-01-30

    Glycidyl methacrylate (GMA) and acrylic acid (AAc) were separately grafted onto polypropylene (PP) monofilament sutures by means of pre-irradiation using a (60)Co γ-source, with the purpose of loading vancomycin via (i) covalent immobilization through the glycidyl groups of GMA and (ii) ionic interaction with AAc moieties. The effect of absorbed radiation dose, monomer concentration, temperature and reaction time on the grafting degree was evaluated in detail. GMA grafting ranged from 25% to 800% while the grafting yield of AAc onto PP could be tuned between 9% and 454%, at doses from 5 to 50 kGy and a dose rate 13.7 kGy/h. Grafting of GMA or AAc decreased the decomposition temperature and made the sutures swellable to a certain extent. GMA grafting led to a continuous, smooth and thick coating, which was suitable for immobilization of up to 1.9 μg vancomycin per gram. The immobilized vancomycin enabled a reduction in the Staphylococcus aureus CFU adhered to the suture surface. On the other hand, dried AAc-functionalized sutures exhibited a rough and cracked surface which was responsible for a minor increase in the coefficient of friction. PP-g-AAc sutures exhibited pH-dependent swelling and remarkably high capability to host vancomycin (up to 109.9 mg/g), particularly those with an intermediate degree of grafting. Some AAc-functionalized sutures were shown able to inhibit bacterial growth after successive challenges with fresh lawns. Therefore, tuning the yield of grafting of GMA or AAc may enable the preparation of drug-suture combination products that retain or release, respectively, antimicrobial agents.

  3. Knotless single-row rotator cuff repair: a comparative biomechanical study of 2 knotless suture anchors.

    PubMed

    Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric

    2013-08-01

    The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. PMID:23937749

  4. VEGF-releasing suture material for enhancement of vascularization: development, in vitro and in vivo study.

    PubMed

    Bigalke, Christian; Luderer, Frank; Wulf, Katharina; Storm, Thilo; Löbler, Marian; Arbeiter, Daniela; Rau, Bettina M; Nizze, Horst; Vollmar, Brigitte; Schmitz, Klaus-Peter; Klar, Ernst; Sternberg, Katrin

    2014-12-01

    As it has been demonstrated that bioactive substances can be delivered locally using coated surgical suture materials, the authors developed a vascular endothelial growth factor (VEGF)-releasing suture material that should promote vascularization and potentially wound healing. In this context, the study focused on the characterization of the developed suture material and the verification of its biological activity, as well as establishing a coating process that allows reproducible and stable coating of a commercially available polydioxanone suture material with poly(l-lactide) (PLLA) and 0.1μg and 1.0μg VEGF. The in vitro VEGF release kinetics was studied using a Sandwich ELISA. The biological activity of the released VEGF was investigated in vitro using human umbilical vein endothelial cells. The potential of the VEGF-releasing suture material was also studied in vivo 5days after implantation in the hind limb of Wistar rats, when the histological findings were analyzed. The essential results, enhanced cell viability in vitro as well as significantly increased vascularization in vivo, were achieved using PLLA/1.0μg VEGF-coated suture material. Furthermore, ELISA measurements revealed a high reproducibility of the VEGF release behavior. Based on the results achieved regarding the dose-effect relationship of VEGF, the stability during its processing and the release behavior, it can be predicted that a bioactive suture material would be successful in later in vivo studies. Therefore, this knowledge could be the basis for future studies, where bioactive substances with different modes of action are combined for targeted, overall enhancement of wound healing.

  5. A carbon nanotubes photoconductive detector for middle and far infrared regions based on porous silicon and a polyamide nylon polymer

    NASA Astrophysics Data System (ADS)

    Saleh, Wasan R.

    2015-06-01

    Sensitive and good response photoconductive detectors working in the middle and far infrared regions were fabricated. These detectors were fabricated based on multi and double walled carbon nanotube films and works at room temperature. The films were deposited on a porous silicon (PSi) nanosurface. The surfaces were functionalized by a thin layer of polyamide nylon polymer to improve the photoresponsivity of the fabricated detectors. The response time of the fabricated MWCNTs-PSi detectors were 30 and 0.22 ms for the middle and far IR region respectively. The functionalisation of the MWCNTs-PSi film surface by the polyamide nylon polymer improved the photoconductive gain, photoresponsivity, and specific conductivity in both MWCNTs-PSi and DWCNTs-PSi detectors. The designed carbon nanotube (CNT) based photodetector has low cost, high sensitivity and reasonable speed for the middle and far IR spectral range without cooling.

  6. Degradation of Nylon 6,6 Fire-Suppression Casing from Plutonium Glove Boxes Under Alpha and Neutron Irradiation

    SciTech Connect

    Millsap, Donald W.; Cournoyer, Michael E.; Landsberger, Sheldon; Tesmer, Joseph R.; Wang, Matthew Y.

    2015-04-23

    Nylon 6,6 tensile specimens, conforming to the casing for self-contained fire extinguisher systems, have been irradiated using both an accelerator He++ ion beam and a 5-Ci PuBe neutron source to model the radiation damage these systems would likely incur over a lifetime of operation within glove boxes. Following irradiation, these samples were mechanically tested using standard practices as described in ASTM D638. The results of the He++ study indicate that the tensile strength of the nylon specimens undergoes some slight (<10%) degradation while other properties of the samples, such as elongation and tangent modulus, appear to fluctuate with increasing dose levels. The He++-irradiated specimens also have a noticeable level of discoloration corresponding to increasing levels of dose. The neutron-irradiated samples show a higher degree of mechanical degradation than the He++-irradiated samples.

  7. Degradation of Nylon 6,6 Fire-Suppression Casing from Plutonium Glove Boxes Under Alpha and Neutron Irradiation

    DOE PAGES

    Millsap, Donald W.; Cournoyer, Michael E.; Landsberger, Sheldon; Tesmer, Joseph R.; Wang, Matthew Y.

    2015-04-23

    Nylon 6,6 tensile specimens, conforming to the casing for self-contained fire extinguisher systems, have been irradiated using both an accelerator He++ ion beam and a 5-Ci PuBe neutron source to model the radiation damage these systems would likely incur over a lifetime of operation within glove boxes. Following irradiation, these samples were mechanically tested using standard practices as described in ASTM D638. The results of the He++ study indicate that the tensile strength of the nylon specimens undergoes some slight (<10%) degradation while other properties of the samples, such as elongation and tangent modulus, appear to fluctuate with increasing dosemore » levels. The He++-irradiated specimens also have a noticeable level of discoloration corresponding to increasing levels of dose. The neutron-irradiated samples show a higher degree of mechanical degradation than the He++-irradiated samples.« less

  8. Near-infrared (NIR) monitoring of Nylon 6 during quenching studied by projection two-dimensional (2D) correlation spectroscopy

    NASA Astrophysics Data System (ADS)

    Shinzawa, Hideyuki; Mizukado, Junji

    2016-11-01

    Evolutionary change in supermolecular structure of Nylon 6 during its melt-quenched process was studied by Near-infrared (NIR) spectroscopy. Time-resolved NIR spectra was measured by taking the advantage of high-speed NIR monitoring based on an acousto-optic tunable filter (AOTF). Fine spectral features associated with the variation of crystalline and amorphous structure occurring in relatively short time scale were readily captured. For example, synchronous and asynchronous 2D correlation spectra reveal the initial decrease in the contribution of the NIR band at 1485 nm due to the amorphous structure, predominantly existing in the melt Nylon 6. This is then followed by the emerging contribution of the band intensity at 1535 nm associated with the crystalline structure. Consequently, the results clearly demonstrate a definite advantage of the high-speed NIR monitoring for analyzing fleeting phenomena.

  9. Flow injection analysis with on-line nylon powder extraction for room-temperature phosphorescence determination of thiabendazole.

    PubMed

    Piccirilli, G N; Escandar, G M

    2009-07-30

    A fast and very selective flow-through phosphorescence optosensor was designed and characterized for the determination of the fungicide thiabendazole in water samples. For the first time, thiabendazole was determined using a flow-through optosensor based on the phosphorescence signals obtained when it is retained in a solid support. While thiabendazole does not phosphoresce in packing materials commonly used to fill the flow-cell, significant emission signals are observed when it is retained on nylon powder in the presence of iodide and sulfite. The experimental set-up was based on a flow-injection manifold coupled to an on-line phosphorescence detector containing nylon powder packed in a conventional flow-cell. Potassium iodide and sodium sulfite were added to sample aliquots to improve the thiabendazole phosphorescence and injected in the flow manifold using water as carrier. After the phosphorescence emission was registered, the analyte was eluted from the packed nylon with a 65% (v/v) methanol-water mixture. Optimal instrumentation, experimental and flow conditions were evaluated. Using a sample volume of 2000 microL, the analytical signal showed a very good linearity in the range 12.9-110 ng mL(-1), with a detection limit of 4.5 ng mL(-1), and a sample throughput of about 14 samples per hour. The effects of the presence of concomitant species in the thiabendazole phosphorescence signal were studied, and a comparison with the fluorescence nylon-powder optosensor was carried out and discussed. Finally, the applicability of the proposed optosensor was tested in water samples, and satisfactory recoveries ranging between 97% and 105% were obtained.

  10. Precise study of nonlinear optical coefficients and hyperpolarizabilities in cold-drawn and poled ferroelectric Nylon 11 films

    NASA Astrophysics Data System (ADS)

    Tsutsumi, Naoto; Mizutani, Toru; Sakai, Wataru; Watanabe, Toshiyuki; Miyata, Seizo

    1998-06-01

    This paper presents a precise study of second-order optical nonlinearity of uniaxially cold-drawn and poled ferroelectric Nylon 11 films. The effects of drawing and poling on refractive indices and second-order nonlinear optical coefficients have been investigated. Drawing caused increase of refractive index (n) parallel to the drawing direction nX, and decrease of n perpendicular to drawing direction in the plane of film nY, as well as decrease of n on the poling direction parallel to film thickness direction nZ. Poling caused significant increase of nZ and decrease of nY. These n results imply that poling aligns the molecular chains so that carbonyl groups in Nylon backbone orient in the poling direction (Z-axis). Cold-drawn and poled Nylon 11 films belong to the mm2 point group. Dependence of second-order harmonic generation (SHG) intensity on incidence angle, i.e., Maker fringe pattern, could be precisely fitted using five independent nonzero tensor components, d33, d32, d31, d15, and d24. However, Kleinman symmetry was not satisfied: d31≠d15 and d32≠d24. The tensor components d33, d31, d15, and d24 increase with increasing remanent polarization, whereas the value of d32 was negligibly small irrespective of the intensity of the remanent polarization. Tensor components of microscopic first-order hyperpolarizability, βzxx, βzyy, βzzz, βxxz, and βyyz were determined. Tensor component βzzz was the largest and βzxx had negative sign. Second-order nonlinearity was largely suppressed in the vicinity of the melting point of Nylon 11.

  11. Internal morphology of the nonsyndromic prematurely fused sagittal suture in the human skull--A preliminary micro-CT study.

    PubMed

    Nowaczewska, W; Ziółkowski, G; Dybała, B

    2015-10-01

    Although nonsyndromic craniosynostosis (NSC) of the sagittal suture is a well-known type of craniosynostosis, little is currently known about the internal morphology of this prematurely fused suture in modern humans. Recently, micro-computed tomography (micro-CT) has been applied as a new tool for the quantitative evaluation of cranial suture morphology. However, so far there are only a small number of reports concerning studies of the internal morphology of prematurely fused sagittal suture in humans using micro-CT. The primary aim of this study was to examine the internal morphology of a completely obliterated sagittal suture in NSC. Two modern human skulls were used in this study: a skull of a child (aged 10 ± 2.5 years) displaying NSC of the sagittal suture and a skull of an adult showing non-prematurely completely obliterated sagittal suture. Quantitative variables of the sagittal sutures were assessed using method proposed by the authors. Porosity, and relative thickness of three bone layers in two examined skulls (inner cortical, diploë and outer cortical) were analysed using micro-CT in three equal sections of the sagittal suture. In the case of the prematurely fused suture, there were statistically significant differences mainly in the mean values of the porosity, thickness and relative thickness of the diploë between the anterior part and the two other parts (central and posterior) of this suture. Significant differences were also observed in some of the analysed variables between the sections of the sagittal suture of the skull with NSC and the normal skull. PMID:26122169

  12. Antibacterial suture vs silk for the surgical removal of impacted lower third molars. A randomized clinical study

    PubMed Central

    Sala-Pérez, Sergi; López-Ramírez, Marta; Quinteros-Borgarello, Milva; Valmaseda-Castellón, Eduardo

    2016-01-01

    Background The aim of this study was to evaluate the clinical and microbiological impact of an antibacterial suture (Monocryl® Plus) in the surgical removal of I3M. Material and Methods A “split-mouth”, prospective pilot clinical study was designed involving 20 patients programmed for the surgical removal of I3M. Each side was randomly sutured with Monocryl® Plus or silk suture and removed for microbiological study 72 hours and 7 days after surgery. Presence of SSI, wound bleeding and the degree of discomfort associated with each type of suture material (scored by means of a visual analog scale) were evaluated. The level of contamination of each material was observed under the scanning electron microscope. Results Wound bleeding upon suture removing was slightly greater after 72 hours and 7 days with black silk suture, though the differences were not statistically significant (p=0.752 and p=0.113, respectively). Patient discomfort was very similar with both types of suture material (p=0.861). Only one case of SSI was recorded with black silk suture after 72 hours. Microbiologically, the antibacterial suture showed a lesser presence of microorganisms (p<0.001, at 72h and p=0.033 at 7th day, respectively). The most common bacterial species included grampositive cocci (Streptococcus viridans group, Neisseria spp., Coagulasenegative Staphylococcus and Peptostreptococcus), gramnegative cocci (Veillonella), grampositive Bacilli (Lactobacillus), and gramnegative Bacilli (Prevotella). Conclusions The greatest antibacterial effect of Monocryl Plus suture was observed after 72 hours. According to most authors, there is no doubt that this antibacterial suture can provide little safety in the control of SSI. Key words:Antibacterial suture, monocryl® plus, vicryl® plus, third molar surgery, postoperative infection, surgical site infection (SSI). PMID:26615503

  13. Correlating antimicrobial activity and model membrane leakage induced by nylon-3 polymers and detergents.

    PubMed

    Hovakeemian, Sara G; Liu, Runhui; Gellman, Samuel H; Heerklotz, Heiko

    2015-09-14

    Most antimicrobial peptides act upon target microorganisms by permeabilizing their membranes. The mode of action is often assessed by vesicle leakage experiments that use model membranes, with the assumption that biological activity correlates with the permeabilization of the lipid bilayer. The current work aims to extend the interpretation of vesicle leakage results and examine the correlation between vesicle leakage and antimicrobial activity. To this end, we used a lifetime-based leakage assay with calcein-loaded vesicles to study the membrane permeabilizing properties of a novel antifungal polymer poly-NM, two of its analogs, and a series of detergents. In conjunction, the biological activities of these compounds against Candida albicans were assessed and correlated with data from vesicle leakage. Poly-NM induces all-or-none leakage in polar yeast lipid vesicles at the polymer's MIC, 3 μg mL(-1). At this and higher concentrations, complete leakage after an initial lag time was observed. Concerted activity tests imply that this polymer acts independently of the detergent octyl glucoside (OG) for both vesicle leakage and activity against C. albicans spheroplasts. In addition, poly-NM was found to have negligible activity against zwitterionic vesicles and red blood cells. Our results provide a consistent, detailed picture of the mode of action of poly-NM: this polymer induces membrane leakage by electrostatic lipid clustering. In contrast, poly-MM:CO, a nylon-3 polymer comprised of both cationic and hydrophobic segments, seems to act by a different mechanism that involves membrane asymmetry stress. Vesicle leakage for this polymer is transient (limited to <100%) and graded, non-specific among zwitterionic and polar yeast lipid vesicles, additive with detergent action, and correlates poorly with biological activity. Based on these results, we conclude that comprehensive leakage experiments can provide a detailed description of the mode of action of membrane

  14. A literature review of the military uses of silver-nylon dressings with emphasis on wartime operations.

    PubMed

    Barillo, David J; Pozza, Morano; Margaret-Brandt, Mary

    2014-12-01

    Medical support of military operations involves treatment of massive soft tissue wounds, thermal burns, open fractures, blast injuries and traumatic amputations under conditions that are often austere and far from supply lines. Military hospitals, as recently deployed in Iraq and Afghanistan, are designed and equipped for stabilization and rapid transfer of injured patients back to their home nation. These austere facilities are often tasked with the emergency or long-term treatment of local populations when injured or burned, further stressing the medical resupply system. Pathogens encountered in contemporary wartime practice are increasingly resistant to antibiotics. Ionic silver is bactericidal against a broad spectrum of bacteria, yeasts and fungi, has been utilized as a topical antiseptic for over 100 years, and has no known clinically-relevant resistance. Silver-nylon dressings, initially stocked in US military hospitals as a burn dressing, are now finding utility as a universal dressing for all types of combat wounds. Compared to conventional burn dressings, they are easier to transport and store, easier to use, and do not need to be changed as frequently, allowing for conservation of nursing resources. In this literature review, the recent military uses of silver-nylon dressings are examined. The stockpiling and use of silver-nylon as a universal military burn and wound dressing is advocated.

  15. Electrospun nylon-6 spider-net like nanofiber mat containing TiO(2) nanoparticles: a multifunctional nanocomposite textile material.

    PubMed

    Pant, Hem Raj; Bajgai, Madhab Prasad; Nam, Ki Taek; Seo, Yun A; Pandeya, Dipendra Raj; Hong, Seong Tshool; Kim, Hak Yong

    2011-01-15

    In this study, electrospun nylon-6 spider-net like nanofiber mats containing TiO(2) nanoparticles (TiO(2) NPs) were successfully prepared. The nanofiber mats containing TiO(2) NPs were characterized by SEM, FE-SEM, TEM, XRD, TGA and EDX analyses. The results revealed that fibers in two distinct sizes (nano and subnano scale) were obtained with the addition of a small amount of TiO(2) NPs. In low TiO(2) content nanocomposite mats, these nanofiber weaves were found uniformly loaded with TiO(2) NPs on their wall. The presence of a small amount of TiO(2) NPs in nylon-6 solution was found to improve the hydrophilicity (antifouling effect), mechanical strength, antimicrobial and UV protecting ability of electrospun mats. The resultant nylon-6/TiO(2) antimicrobial spider-net like composite mat with antifouling effect may be a potential candidate for future water filter applications, and its improved mechanical strength and UV blocking ability will also make it a potential candidate for protective clothing.

  16. Investigation Of Dielectric Behaviors Of Nanoclay Filled Epoxy And PP/NYLON66 Nanocomposites For Cable Insulation Application

    NASA Astrophysics Data System (ADS)

    Rashmi, Renukappa, N. M.; Siddaramaiah

    2010-10-01

    High performance polymer nanocomposites are emerging as a new class of materials for its demanding applications as insulating material. The outstanding properties of nanoclay make them an attractive candidate for preparing advanced composite materials with multi functional features for electrical and electronics applications. A series of nanoclay incorporated epoxy and polypropylene/nylon66 (50/50 blend) nanocomposites have been prepared via chemical and melt mixing methods respectively. The fabricated nanocomposites have been characterized for dielectric behaviors such as dielectric constant (ɛ r ) and dissipation factor (tan δ). The effect of filler content, frequency, temperature and sea water ageing on dielectric behavior of nanocomposites has been investigated. The variation in the diffusion coefficient (D) of the material aged in water at different temperature with different percentage of nanoclay loaded epoxy and PP/nylon66 nanocomposites were calculated. It is observed that at increase in ageing temperature relatively increases the diffusion coefficient of the material. The measured dielectric results of the nanocomposites reveals that a significant influence of frequency and sea water ageing and marginal change with temperature. Higher dielectric constant was noticed for epoxy nanocomposites as compared to PP/nylon66 composites

  17. Uncertainties of Gaseous Oxidized Mercury Measurements Using KCl-Coated Denuders, Cation-Exchange Membranes, and Nylon Membranes: Humidity Influences.

    PubMed

    Huang, Jiaoyan; Gustin, Mae Sexauer

    2015-05-19

    Quantifying the concentration of gaseous oxidized mercury (GOM) and identifying the chemical compounds in the atmosphere are important for developing accurate local, regional, and global biogeochemical cycles. The major hypothesis driving this work was that relative humidity affects collection of GOM on KCl-coated denuders and nylon membranes, both currently being applied to measure GOM. Using a laboratory manifold system and ambient air, GOM capture efficiency on 3 different collection surfaces, including KCl-coated denuders, nylon membranes, and cation-exchange membranes, was investigated at relative humidity ranging from 25 to 75%. Recovery of permeated HgBr2 on KCl-coated denuders declined by 4-60% during spikes of relative humidity (25 to 75%). When spikes were turned off GOM recoveries returned to 60 ± 19% of permeated levels. In some cases, KCl-coated denuders were gradually passivated over time after additional humidity was applied. In this study, GOM recovery on nylon membranes decreased with high humidity and ozone concentrations. However, additional humidity enhanced GOM recovery on cation-exchange membranes. In addition, reduction and oxidation of elemental mercury during experiments was observed. The findings in this study can help to explain field observations in previous studies.

  18. A literature review of the military uses of silver-nylon dressings with emphasis on wartime operations.

    PubMed

    Barillo, David J; Pozza, Morano; Margaret-Brandt, Mary

    2014-12-01

    Medical support of military operations involves treatment of massive soft tissue wounds, thermal burns, open fractures, blast injuries and traumatic amputations under conditions that are often austere and far from supply lines. Military hospitals, as recently deployed in Iraq and Afghanistan, are designed and equipped for stabilization and rapid transfer of injured patients back to their home nation. These austere facilities are often tasked with the emergency or long-term treatment of local populations when injured or burned, further stressing the medical resupply system. Pathogens encountered in contemporary wartime practice are increasingly resistant to antibiotics. Ionic silver is bactericidal against a broad spectrum of bacteria, yeasts and fungi, has been utilized as a topical antiseptic for over 100 years, and has no known clinically-relevant resistance. Silver-nylon dressings, initially stocked in US military hospitals as a burn dressing, are now finding utility as a universal dressing for all types of combat wounds. Compared to conventional burn dressings, they are easier to transport and store, easier to use, and do not need to be changed as frequently, allowing for conservation of nursing resources. In this literature review, the recent military uses of silver-nylon dressings are examined. The stockpiling and use of silver-nylon as a universal military burn and wound dressing is advocated. PMID:25418434

  19. The effect of core suture flexor tendon repair techniques on gliding resistance during static cycle motion and load to failure: a human cadaver study

    PubMed Central

    Moriya, T.; Larson, M. C.; Zhao, C.; An, K.-N.; Amadio, P. C.

    2011-01-01

    The purpose of this study was to describe a modification of the Massachusetts General Hospital (MMGH) tendon repair and to compare it with three other suture techniques. Twenty human flexor digitorum profundus (FDP) tendons were randomly assigned to the modified Pennington (MP) suture and the MMGH suture. These were compared to the modified Kessler (MK) and Massachusetts General Hospital (MGH) sutures, using data from a previous study. All tendons were repaired with a similar epitendinous stitch and core sutures of 4-0 FiberWire. There was no significant difference in the normalized gliding resistance within the two-strand or four-strand core repair groups. The MP suture had significantly higher 2 mm gap force and ultimate load to failure than the MK suture. The MMGH suture had significantly higher 2 mm gap force and maximum failure ultimate load than the MGH suture. All repairs failed by knot unravelling. PMID:21987278

  20. Three-dimensional echo-guided suture of atrial septal defect with Maniceps in an experimental model.

    PubMed

    Orihashi, Kazumasa; Takahashi, Shinya; Ozawa, Masamichi; Herlambang, Bagus; Takasaki, Taiichi; Sato, Katsutoshi; Kurosaki, Tatsuya; Imai, Katsuhiko; Sueda, Taijiro

    2010-09-01

    Toward the establishment of suture closure procedures for atrial septal defect or patent foramen ovale under guidance of three-dimensional (3D) echocardiography but without use of cardiopulmonary bypass (off-pump surgery), an experimental study was conducted using a laparoscopic suture instrument, Maniceps. First, the panel setting of the 3D echo system which was optimal for precisely visualizing the surgical instruments on the image display with the least time delay was determined. The optimal setting was: 1) harmonic imaging, 2) no smoothing, 3) low scanning line density, and 4) a scanning range around 55 degrees. Using an ex vivo model of atrial septal defect, 3D echo-guided surgical procedures were attempted in three steps. First, grasping of the edge of the defect with a forceps was attempted. It was feasible in every direction. Reverberation artifact occasionally disturbed imaging of the defect edge. Second, transfixion suture of the facing edges was attempted. Guided by 3D echo, serial sutures were feasible, but interlocking of the thread was a pitfall. Third, continuous suture of the defect was attempted under 3D echo guidance. Following the initial suture bite on one side, continuous suture could be performed under echo guidance. Deformity of the Maniceps needle after repeated sutures was a limitation. In conclusion, suture closure of the defect under 3D echo guidance using the Maniceps system is feasible in an ex vivo ASD model as visualization is optimized by panel setting for guiding surgical procedures.

  1. Astigmatism in cataract surgery.

    PubMed Central

    Luntz, M. H.; Livingston, D. G.

    1977-01-01

    We report on our investigation into astigmatism in 40 eyes following a corneal cataract incision closed with a continuous 10/0 nylon monofilament suture (Ethilon). Immediately after surgery there was astigmatism caused by the nylon suture (suture-induced astigmatism), its severity depending on the tightness of the suture. It ranged from 1 to 10-5 dioptres, the mean value 4-09 dioptres with a standard deviation of +/-2-5. Removing the nylon suture eliminated this astigmatism and within a few weeks the corneal astigmatism correction in 48% of eyes returned to the preoperative level. In 80% of eyes the difference between the final postoperative corneal astigmatism (4 months after removing the continuous suture) and the preoperative astigmatism was 0-75 dioptres or less and the maximum change was 1-5 dioptres. In 40% of eyes the axis of the cylinder changed from a horizontal to an oblique axis but did not change from a with- to against-the-rule axis. The degree of astigmatism remained constant while the suture was in place and in 50% of eyes was equal to or less than 3 dioptres. The mean of the spherical equivalents was 11-31 dioptres with a standard deviation of +/-1-25. A spectacle correction 14 days after operation prescribed either as the mean spherical equivalent (11-50 dioptres) or according to the patient's refraction will give satisfactory vision until the suture is removed 4 months after operation. The degree of astigmatism following a corneal section and continuous nylon suture compares very favourably with astigmatism following other suturing techniques for cataract. Images PMID:326304

  2. Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears

    PubMed Central

    Milchteim, Charles; Branch, Eric A.; Maughon, Ty; Hughey, Jay; Anz, Adam W.

    2016-01-01

    Background: Longitudinal meniscus tears are commonly encountered in clinical practice. Meniscus repair devices have been previously tested and presented; however, prior studies have not evaluated repair construct designs head to head. This study compared a new-generation meniscus repair device, SpeedCinch, with a similar established device, Fast-Fix 360, and a parallel repair construct to a crossed construct. Both devices utilize self-adjusting No. 2-0 ultra–high molecular weight polyethylene (UHMWPE) and 2 polyether ether ketone (PEEK) anchors. Hypothesis: Crossed suture repair constructs have higher failure loads and stiffness compared with simple parallel constructs. The newer repair device would exhibit similar performance to an established device. Study Design: Controlled laboratory study. Methods: Sutures were placed in an open fashion into the body and posterior horn regions of the medial and lateral menisci in 16 cadaveric knees. Evaluation of 2 repair devices and 2 repair constructs created 4 groups: 2 parallel vertical sutures created with the Fast-Fix 360 (2PFF), 2 crossed vertical sutures created with the Fast-Fix 360 (2XFF), 2 parallel vertical sutures created with the SpeedCinch (2PSC), and 2 crossed vertical sutures created with the SpeedCinch (2XSC). After open placement of the repair construct, each meniscus was explanted and tested to failure on a uniaxial material testing machine. All data were checked for normality of distribution, and 1-way analysis of variance by ranks was chosen to evaluate for statistical significance of maximum failure load and stiffness between groups. Statistical significance was defined as P < .05. Results: The mean maximum failure loads ± 95% CI (range) were 89.6 ± 16.3 N (125.7-47.8 N) (2PFF), 72.1 ± 11.7 N (103.4-47.6 N) (2XFF), 71.9 ± 15.5 N (109.4-41.3 N) (2PSC), and 79.5 ± 25.4 N (119.1-30.9 N) (2XSC). Interconstruct comparison revealed no statistical difference between all 4 constructs regarding maximum

  3. Upper Mantle Structure Around the Trans-European Suture Zone

    NASA Astrophysics Data System (ADS)

    Janutyte, Ilma; Majdanski, Mariusz; Voss, Peter H.; Kozlovskaya, Elena

    2014-05-01

    The Trans-European Suture Zone (TESZ) is the transition between old Proterozoic lithosphere in Northern and Eastern Europe and the younger Phanerozoic lithosphere in Central and Western Europe. The presented study is a part of the PASSEQ 2006-2008 project which is linked to the TOR project realized during 1996-1997. The PASSEQ and the TOR projects aimed to study the lithosphere and asthenosphere structure around the TESZ, but the latter was focused on the northwestern part of the TESZ between Sweden and Denmark - Germany, while the PASSEQ project was focused on the TESZ mainly beneath Poland. During the PASSEQ project 139 short-period and 49 broadband temporary seismic stations were deployed along the transect stretching from Germany throughout Czech Republic and Poland to Lithuania. The array recorded continuous seismic data from May, 2006 to June, 2008. In our study we used data of all available PASSEQ seismic stations and seismic stations of the national seismological networks of the participating countries and compiled a data set of teleseismic P-wave arrivals. The full data set consists of 8308 manually picked arrivals. Due to limited computational power we used the data of the highest quality only, i.e. 6008 picks. The non-linear teleseismic tomography algorithm TELINV was used to obtain the model of P-wave velocity perturbations in the upper mantle around the TESZ. We recovered the upper mantle structure from 70 km down to 350 km in the study area. The results show ±6.5 % P-wave velocity variations compared to the IASP91 velocity model. We found higher velocities beneath the old East European Craton (EEC) east of the TESZ and lower ones beneath the younger Western Europe west of the TESZ. The thickest litosphere was found beneath the EEC (Lithuania) where the higher velocities continue to about 300 km or even more. To the west of the TESZ under the Variscides the average depth of the lithosphere-asthenosphere boundary (LAB) is about 100 km. The TESZ appears

  4. [In vitro studies of the mechanical load capability of resorbable monofilament suture materials].

    PubMed

    Bremer, Felicia; Gellrich, Nils-Claudius; Stiesch, Meike

    2009-01-01

    In a vast spectrum of wound closures there is an indication for resorbable suture materials. For surgeons detailed knowledge of the physicochemical properties is important in order to find the right suture for each indication. For this purpose, various new monofilament polymers were employed. The objective of the present study was to investigate the effects of hydrolysis and gamma-irradiation on the linear strength. The final analysis of all tested suture materials concluded that gamma-irradiation had no effects on linear strength. However, the analysis showed significant discrepancies between individual polymers with regard to loss of tensile strength associated with hydrolysis. Polydioxanone- and caprolactone-lactid-based resorbable suture materials both displayed adequate tensile strength after a five-week period of hydrolysis. In comparison the triblock-copolymer is subject to rapid degradation. Polydioxanone- and caprolactone-lactid-based resorbable suture materials are indicated for use in tissues which require mechanical support over a longer period. Monosyn is more suitable for short-term wound support. PMID:19852206

  5. Clinical Outcome and Wound Healing following Carpal Tunnel Decompression: A Comparison of Two Common Suture Materials

    PubMed Central

    MacFarlane, Robert J.; Donnelly, Thomas D.; Morapudi, Syam; Waseem, Mohammad

    2014-01-01

    Introduction. Debate exists amongst surgeons regarding the ideal suture material for skin closure in carpal tunnel decompression (CTD). This study compares wound related complications, patient satisfaction, and functional outcome following open carpal tunnel decompression in patients undergoing wound closure with either of two common absorbable and nonabsorbable suture types. Materials and Methods. 53 patients underwent CTD with either 4/0 polypropylene (ProleneTM, n = 28) or 4/0 polyglactin (Vicryl RapideTM, n = 25) for skin closure. QuickDASH, VAS satisfaction scores, and Southampton wound scores were assessed preoperatively and at 2 and 6 weeks postoperatively. Results. At 6 weeks the mean QuickDASH scores postoperatively were 18.54 and 17.70 for absorbable and nonabsorbable sutures, respectively, (P = 0.86). The mean VAS scores were 0.61 and 0.42 (P = 0.91), respectively. All patients achieved a Southampton wound score of 0 by 6 weeks except one, who achieved 1C in the nonabsorbable group, equivalent to mild erythema. There were no complications in either group. Conclusion. Both suture types are safe and effective materials for CTD, and we recommend surgeons to choose according to personal preference, handling properties, and resources available for suture removal. PMID:25165693

  6. Creep rupture behavior of polypropylene suture material and its applications as a time-release mechanism

    SciTech Connect

    Kusy, R.P.; Whitley, J.Q.

    1983-05-01

    The controlled failure of polypropylene (PP) sutures is studied via creep rupture tests. From plots of log time (tB) vs. stress (sigma), linear relationships are generated over the failure times of 1-1000 h. Results show that as a function of stress, the time dependence varies with irradiation dose (15, 20, 25, and 50 Mrad), irradiation atmosphere (air and vacuum), suture diameter (7-0, 6-0, 5-0, and 4-0), and test temperature (26 and 37 degrees C). For a given stress, the time to failure is least for the greatest dose in the presence of air and at the highest temperature. When suture loops are wrapped around a small wire sheave, however, failure occurs in the largest suture as much as two decades sooner than the smallest suture studied. Within the limitations stated herein, they are independent of test method, loop diameter, aging, and humidity. Consequently, after irradiation in vacuum and postirradiation heat treatment, the processed material may be stored at room temperature for at least 1 month. Such materials are advocated when the time release of a dental or medical device is required, for example, in the self-activating cleft palate appliance.

  7. The Optimal Placement of Sutures in All-inside Repair of Meniscocapsular Separation

    PubMed Central

    Tiftikci, Uğur; Serbest, Sancar

    2016-01-01

    Background: The aim of this study was to show the effects on the meniscus of repair applied from the femoral, the femoral-tibial and the tibial surfaces. Methods: In the treatment of meniscocapsular separation, although the accepted gold standard technique in the past was the inside-out suture technique, the current treatment method is all-inside repair methods. The all-inside techniques include the hook method and applications with a meniscus suture device. The hook method is difficult with a steep learning curve. In meniscus repair applied with the all-inside meniscus devices, the application of the suture can change the anatomic structure and position of the meniscus. Results: The suturing method applied from the tibial section of the meniscus does not disrupt the anatomic position of the meniscus in meniscocapsular separation. Thus, the optimum conditions are provided for restoration of the functions of the meniscus. Conclusion: The optimal repair in meniscocapsular separations can be considered to be that made with sutures from the tibial section of the meniscus. This technique may be helpful in obtaining better clinical results. PMID:27347236

  8. Successful treatment of recurrent rectal prolapse using three Thiersch sutures in children.

    PubMed

    Chauhan, Kashif; Gan, Richard Wei Chern; Singh, Shailinder

    2015-01-01

    Many techniques are described to manage recurrent rectal prolapse in children, including repeated Thiersch stitch, phenol injections, Delorme and Altemeier procedures, and rectopexy. We describe a case of successful treatment of rectal prolapse by placing three Thiersch sutures circumferentially along the anal canal--a simple and novel modification of a well-known procedure. An 8-year-old boy with full-thickness rectal prolapse was treated with laxatives to no avail. He was subsequently treated with phenol-in-almond-oil injection and insertion of a 1/0PDS Thiersch suture. The effects were temporary with recurrence 3 months later. A further phenol-in-almond-oil injection was given and a 1/0PDS Thiersch suture placed, and the patient was discharged on laxatives. Recurrence occurred again at 3 months. This was treated with three circumferential Thiersch sutures along the anal canal--one Prolene 2/0 and two 1/0PDS. There has been no recurrence at follow-up. Placement of three sequential Thiersch sutures along the rectum is effective in treating recurrent rectal prolapse and a good alternative to major rectopexy. PMID:26607187

  9. SR and LR Union Suture for the Treatment of Myopic Strabismus Fixus: Is Scleral Fixation Necessary?

    PubMed Central

    Lam, Carol P. S.; Yam, Jason C. S.; Lau, Flora H. S.; Fan, Dorothy S. P.; Wong, C. Y.; Yu, Christopher B. O.; Lau, Winnie W. Y.

    2015-01-01

    Purpose. To evaluate and compare the effectiveness of scleral fixation SR and LR union suture and nonscleral fixation union suture for the treatment of myopic strabismus fixus. Methods. Retrospective review of 32 eyes of 22 patients with myopic strabismus fixus who had undergone union suture of superior rectus (SR) and lateral rectus (LR) with or without scleral fixation, and follow-up longer than 6 months at Hong Kong Eye Hospital from 2006 to 2013. Surgical techniques and outcomes in terms of ocular alignment are analyzed. Results. There is significant overall improvement both in postoperative angle of esodeviation (P < 0.01) and postoperative range of movement (P = 0.042). Comparing between the sclera fixation group (11 eyes) versus nonscleral fixation group (21 eyes), the postoperative horizontal deviation, the postoperative vertical deviation, successful outcome, and the change in horizontal deviation were not significantly different (P > 0.05). Conclusions. Union suture of SR and LR is an effective procedure in correcting myopic strabismus fixus. Fixation of the union suture to the sclera does not improve surgical outcome. PMID:25954751

  10. Simple and strong: twisted silver painted nylon artificial muscle actuated by Joule heating

    NASA Astrophysics Data System (ADS)

    Mirvakili, Seyed M.; Rafie Ravandi, Ali; Hunter, Ian W.; Haines, Carter S.; Li, Na; Foroughi, Javad; Naficy, Sina; Spinks, Geoffrey M.; Baughman, Ray H.; Madden, John D. W.

    2014-03-01

    Highly oriented nylon and polyethylene fibres shrink in length when heated and expand in diameter. By twisting and then coiling monofilaments of these materials to form helical springs, the anisotropic thermal expansion has recently been shown to enable tensile actuation of up to 49% upon heating. Joule heating, by passing a current through a conductive coating on the surface of the filament, is a convenient method of controlling actuation. In previously reported work this has been done using highly flexible carbon nanotube sheets or commercially available silver coated fibres. In this work silver paint is used as the Joule heating element at the surface of the muscle. Up to 29% linear actuation is observed with energy and power densities reaching 840 kJ m-3 (528 J kg-1) and 1.1 kW kg-1 (operating at 0.1 Hz, 4% strain, 1.4 kg load). This simple coating method is readily accessible and can be applied to any polymer filament. Effective use of this technique relies on uniform coating to avoid temperature gradients.

  11. Experimental characterization of thermally-activated artificial muscles based on coiled nylon fishing lines

    NASA Astrophysics Data System (ADS)

    Cherubini, Antonello; Moretti, Giacomo; Vertechy, Rocco; Fontana, Marco

    2015-06-01

    The discovery of an innovative class of thermally activated actuators based on twisted polymeric fibres has opened new horizons toward the development of effective devices that can be easily manufactured using inexpensive materials such as fishing lines or sewing threads. These new devices show large deformations when heated together with promising performance in terms of energy and power densities. With the aim of providing information and data useful for the future engineering applications, we present the results of a thermo-mechanical characterization conducted on a specific type of twisted polymeric fibre (i.e. nylon-made coiled actuators) that is considered particularly promising. A custom experimental test-bench and procedure have been developed and employed to run isothermal and isometric tensile tests on a set of specimens that are fabricated with a simple and repeatable process. The results of the experiments highlight some important issues related to the response of these actuators such as hysteresis, repeatability, predictability and stored elastic energy.

  12. Medium effects on minimum inhibitory concentrations of nylon-3 polymers against E. coli.

    PubMed

    Choi, Heejun; Chakraborty, Saswata; Liu, Runhui; Gellman, Samuel H; Weisshaar, James C

    2014-01-01

    Minimum inhibitory concentrations (MICs) against E. coli were measured for three nylon-3 polymers using Luria-Bertani broth (LB), brain-heart infusion broth (BHI), and a chemically defined complete medium (EZRDM). The polymers differ in the ratio of hydrophobic to cationic subunits. The cationic homopolymer is inert against E. coli in BHI and LB, but becomes highly potent in EZRDM. A mixed hydrophobic/cationic polymer with a hydrophobic t-butylbenzoyl group at its N-terminus is effective in BHI, but becomes more effective in EZRDM. Supplementation of EZRDM with the tryptic digest of casein (often found in LB) recapitulates the LB and BHI behavior. Additional evidence suggests that polyanionic peptides present in LB and BHI may form electrostatic complexes with cationic polymers, decreasing activity by diminishing binding to the anionic lipopolysaccharide layer of E. coli. In contrast, two natural antimicrobial peptides show no medium effects. Thus, the use of a chemically defined medium helps to reveal factors that influence antimicrobial potency of cationic polymers and functional differences between these polymers and evolved antimicrobial peptides.

  13. Analysis of Dyes Extracted from Millimeter-Size Nylon Fibers by Micellar Electrokinetic Chromatography

    SciTech Connect

    Lewis, L.A.

    2001-07-30

    The Learning Objective is to present to the forensic community a potential qualitative/quantitative method for trace-fiber color comparisons using micellar electrokinetic chromatography (MEKC). Developing a means of analyzing extracted dye constituents from millimeter-size nylon fiber samples was the objective of this research initiative. Aside from ascertaining fiber type, color evaluation and source comparison of trace-fiber evidence plays a critical role in forensic-fiber examinations. Literally thousands of dyes exist to date, including both natural and synthetic compounds. Typically a three-color-dye combination is employed to affect a given color on fiber material. The result of this practice leads to a significant number of potential dye combinations capable of producing a similar color and shade. Since a typical forensic fiber sample is 2 mm or less in length, an ideal forensic dye analysis would qualitatively and quantitatively identify the extracted dye constituents from a sample size of 1 mm or smaller. The goal of this research was to develop an analytical method for comparing individual dye constituents from trace-fiber evidence with dyes extracted from a suspected source, while preserving as much of the original evidence as possible.

  14. [Vehicle-assisted suicide with a nylon rope causing complete decapitation].

    PubMed

    Blässer, Katharina; Tatschner, Thomas; Bohnert, Michael

    2013-01-01

    The present case deals with the unusual suicide method of a 36-year-old man who fastened one end of a nylon rope to a tree, guided the other end into a van through the open tailgate and placed the loop round his neck. Then he stepped on the accelerator. Before, he had marked the point on the ground where the rope would tighten. As the rope tightened complete decapitation occurred at a speed of about 35 km/h. Autopsy showed a nearly circular abrasion zone around the site of transection slightly ascending towards the nape, a fracture of the cervical spine between the 3rd and 4th vertebra and a fracture of the thoracic spine between the 7th and 8th vertebra. The test for air embolism of the heart was positive. Macroscopically, no evidence of blood aspiration was found. Histological investigation showed general anaemia and minor blood aspiration in the lungs. Wound morphology was largely in line with the injury patterns described after decapitation in the literature. However, our results differed in that blood aspiration was discernible only under the microscope and there was a second fracture of the spine. Decapitation as a suicide method is an expression of enormous autoaggression and is categorized as a "hard" suicide method. It is used predominantly by men and its occurrence in the spectrum of suicidal actions is rare. Police investigations revealed that the man had led a sort of double life with a sexually motivated background and had suffered from depressive episodes.

  15. Effect of different percent loadings of nanoparticles and food processing conditions on the properties of nylon 6 films

    NASA Astrophysics Data System (ADS)

    Allafi, Ahmad R.

    Nylon 6 organoclay nanocomposites were prepared by melt processing using a twin screw extruder. Five different films were produced with five different % loadings (0, 2, 4, 6, and 8%). This study had three main objectives. The first was to investigate the effects of loading percentages on the barrier, thermal and mechanical properties of nylon 6 nanocomposite materials. The second was to study the effects of 0, 50 and 80% RH on the oxygen permeation of the nylon 6/nanocomposite films. The third was to investigate the properties of nylon 6 nanocomposite materials exposed to typical food processing conditions. These films were tested for their permeabilities to oxygen (OTR), carbon dioxide (CO2TR), and water vapor (WVTR). Thermal properties testing on the samples included differential scanning calorimetry (DSC) and dynamic mechanical analysis (DMA). Tensile strength at break, tensile modulus at break, and the percent elongation for the five films were examined using an INSTRON tester. Transmission electron microscopy (TEM) was used to investigate the morphology of the five films. Results showed that all gas barriers significantly increased with percent loading but there were no significant differences (P>0.05) between the 6 and 8% for the CO2TR. For the DMA, the storage modulus also significantly increased (P<0.05) with increasing loading except between the 2 and 4% concentrations. For the DSC analyses, enthalpy of fusion decreased slightly from an average of 39 J/g (control) to 32J/g (8% loading). The melt temperature also decreased from 227 to 222°C between those loadings. High pressure processed samples had the highest barrier against oxygen permeation when compared with the retorted and controls. Retorting seemed to reduce the tensile strength slightly; however, no significant changes in modulus and elongation occurred after retorting and HPP. These results showed that increasing percent loadings increased the stiffness of the material at the expense of its

  16. Allergy to Prolene Sutures in a Dural Graft for Chiari Decompression

    PubMed Central

    Cajigas, Iahn; Burks, S. Shelby; Gernsback, Joanna; Fine, Lauren; Moshiree, Baharak; Levi, Allan D.

    2015-01-01

    Allergy to Prolene suture is exceedingly rare with only 5 cases reported in the literature. There have been no such cases associated with neurosurgical procedures. Diagnosis is nearly always delayed in spite of persistent symptomatology. A 27-year-old girl with suspected Ehlers-Danlos, connective tissue disorder, underwent posterior fossa decompression for Chiari Type 1 malformation. One year later, the patient presented with urticarial rash from the neck to chest. Cerebrospinal fluid and blood testing, magnetic resonance imaging, and intraoperative exploration did not suggest allergic reaction. Eventually skin testing proved specific Prolene allergy. After suture material was removed, the patient no longer complained of pruritus or rash. This single case highlights the important entity of allergic reaction to suture material, namely, Prolene, which can present in a delayed basis. Symptomatology can be vague but has typical allergic characteristics. Multidisciplinary approach is helpful with confirmatory skin testing as a vital part of the workup. PMID:26798347

  17. Hamstring graft fixation in MPFL reconstruction at the patella using a transosseous suture technique.

    PubMed

    Siebold, Rainer; Chikale, Shivanand; Sartory, Nico; Hariri, Nawid; Feil, Sven; Pässler, Hans H

    2010-11-01

    Controversy still exists about fixation methods of a hamstring graft to the patella in case of medial patellofemoral ligament (MPFL) reconstruction. This article presents a surgical technique of hamstring tendon graft fixation to the anatomical MPFL insertion on the patella using transosseous sutures. A superficial bony sulcus is created at the anatomical MPFL insertion site on the medial patellar rim with a bur. A looped hamstring tendon graft is fixed to this superficial sulcus by a pair of nonresorbable transosseous sutures passed across the patella. The retinaculum is sutured on top of the hamstring tendon graft at the level of the patella for additional fixation. The technique avoids bone tunnels as well as hardware at the patella. It reduces the risk of intraoperative or postoperative patella fracture or implant-related complications. The stable transosseous fixation technique allows for early rehabilitation.

  18. Allergy to Prolene Sutures in a Dural Graft for Chiari Decompression.

    PubMed

    Cajigas, Iahn; Burks, S Shelby; Gernsback, Joanna; Fine, Lauren; Moshiree, Baharak; Levi, Allan D

    2015-01-01

    Allergy to Prolene suture is exceedingly rare with only 5 cases reported in the literature. There have been no such cases associated with neurosurgical procedures. Diagnosis is nearly always delayed in spite of persistent symptomatology. A 27-year-old girl with suspected Ehlers-Danlos, connective tissue disorder, underwent posterior fossa decompression for Chiari Type 1 malformation. One year later, the patient presented with urticarial rash from the neck to chest. Cerebrospinal fluid and blood testing, magnetic resonance imaging, and intraoperative exploration did not suggest allergic reaction. Eventually skin testing proved specific Prolene allergy. After suture material was removed, the patient no longer complained of pruritus or rash. This single case highlights the important entity of allergic reaction to suture material, namely, Prolene, which can present in a delayed basis. Symptomatology can be vague but has typical allergic characteristics. Multidisciplinary approach is helpful with confirmatory skin testing as a vital part of the workup. PMID:26798347

  19. Arthroscopic 4-Point Suture Fixation of Anterior Cruciate Ligament Tibial Avulsion Fractures

    PubMed Central

    Boutsiadis, Achilleas; Karataglis, Dimitrios; Agathangelidis, Filon; Ditsios, Konstantinos; Papadopoulos, Pericles

    2014-01-01

    Tibial eminence avulsion fractures are rare injuries occurring mainly in adolescents and young adults. When necessary, regardless of patient age, anatomic reduction and stable internal fixation are mandatory for fracture healing and accurate restoration of normal knee biomechanics. Various arthroscopically assisted fixation methods with sutures, anchors, wires, or screws have been described but can be technically demanding, thus elongating operative times. The purpose of this article is to present a technical variation of arthroscopic suture fixation of anterior cruciate ligament avulsion fractures. Using thoracic drain needles over 2.4-mm anterior cruciate ligament tibial guidewires, we recommend the safe and easy creation of four 2.9-mm tibial tunnels at different angles and at specific points. This technique uses thoracic drain needles as suture passage cannulas and offers 4-point fixation stability, avoiding potential complications of bony bridge fracture and tunnel connection. PMID:25685674

  20. Entrapment of Common Peroneal Nerve by Surgical Suture following Distal Biceps Femoris Tendon Repair

    PubMed Central

    Nakazora, Shigeto; Kato, Ko

    2016-01-01

    We describe entrapment of the common peroneal nerve by a suture after surgical repair of the distal biceps femoris tendon. Complete rupture of the distal biceps femoris tendon of a 16-year-old male athlete was surgically repaired. Postoperative common peroneal nerve palsy was evident, but conservative treatment did not cause any neurological improvement. Reexploration revealed that the common peroneal nerve was entrapped by the surgical suture. Complete removal of the suture and external neurolysis significantly improved the palsy. The common peroneal nerve is prone to damage as a result of its close proximity to the biceps femoris tendon and it should be identified during surgical repair of a ruptured distal biceps femoris tendon. PMID:27703826