  1. COMPARATIVE STUDY OF MICROANASTOMOSIS WITH DISTINCT 10-0 NYLON SUTURES IN RATS

    PubMed Central

    Silva, Ricardo Teixeira e; Barros, Thiago Felipe Santos; de Carvalho, José Thomé; Ribeiro, André Araújo; Pires, André Fernandes; Wei, Teng Hsiang

    2016-01-01

    ABSTRACT Objective: The aim of this study is to compare micro-sutures commonly used in our midst. Methods: In this double-blind study, 30 Wistar rats were operated randomly divided into three groups matched according to the suture used (Nylon 10-0, 75micron, brands Microsuture(r), Polysuture(r) and Ethicon(r)). We analyzed the number of surgical nodes required, bleeding, surgical time and histological evaluation. Results: There was no significant difference between the amount of stitches of arterial suture per anastomosis. Surgical time was longer in Microsuture(r) group as compared to Polysuture(r) (p ≤ 0.05). Bleeding in Microsuture(r) group was higher when compared to the others (p <0.01). In the histological analysis, the Microsuture(r) group showed a greater tendency to develop fibrosis and aneurysm in surgical site than the others (p <0.01 and p≤0,05, respectively). Similarly, the Ethicon(r) group showed less tendency to myointimal proliferation than the rest. (p = 0.025). Conclusion: The results confirm the relevance of the choice of surgical thread as an independent determining factor for the success of the procedure, besides serving as a rational subsidy for a better cost-benefit analysis. Level of Evidence I, Experimental Study, Controlled Animal Study. PMID:26997912

  2. A comparison between three brands of 10.0 nylon sutures.

    PubMed

    Kappelhof, J P; Swart, W; Willekens, B L

    1989-08-01

    10.0 nylon sutures from three different manufacturers were compared on the basis of the scanning electron microscopic aspect, the maximum tensile strength of the thread and the maximum tensile strength of the knot (single throw). Scanning electron microscopy revealed identical surface characteristics and identical diameters (approximately 30 micrometers) for all threads. Threads which had been pulled on became wavy and showed markedly thinned and flattened segments. Maximum tensile strength was measured by a simple device, which is described. The maximum tensile strength of the thread varied considerably between the three brands (from 31.3 gr, S.D. 2.0 gr, to 46.2 gr, S.D. 3.7 gr.) The maximum tensile strength of the knot (single throw) was approximately the same for all three (ranging from 25.9 gr, S.D. 4.1 gr to 28.2 gr, S.D. 2.6 gr). PMID:2625082

  3. [Astigmatism following cataract surgery: comparison following wound closure with nylon suture and Mersilene].

    PubMed

    Bigar, F

    1990-05-01

    Mersilene (polyester fiber) is stronger and less elastic than nylon suture material. In contrast to nylon, Mersilene does not appear to be susceptible to biodegradation in the long term. After a follow-up period of 6 months, the regression of surgically induced astigmatism following extracapsular cataract extraction and lens implantation with a conventional 150 degree corneoscleral incision was in the same range with nylon monofilament 10-0 and Mersilene 10-0. With nylon single sutures (14 patients) there was a reduction from 3.5 and with Mersilene (12 patients) from 3.9 to 0.9 diopters. PMID:2195225

  4. Comparison of the reaction of the cornea to nylon and stainless steel sutures: an animal study.

    PubMed

    Rijneveld, W J; Jongebloed, W L; Worst, J G; Houtman, W A

    1989-08-01

    In 11 rabbits a comparison was made between the reactions of the cornea to nylon and to stainless steel sutures, macroscopically and by means of scanning electron-microscopy (SEM). Macroscopically, the wounds sutured with steel thread showed much less reaction than the wounds sutured with nylon. Vascularization was never encountered in the wounds sutured with steel thread. SEM examination also showed clear differences, which became noticeable within a short time. Both on the suture and round the opening in the cornea extensive deposits of material are seen within a short time (1 week) in the case of nylon, in the case of stainless steel this reaction is much less marked. A few weeks later deposits also appear on the steel thread, but these have a different composition and contain no material suggestive of an inflammatory reaction. PMID:2483135

  5. Newly made antibacterial braided nylon sutures. I. In vitro qualitative and in vivo preliminary biocompatibility study.

    PubMed

    Chu, C C; Tsai, W C; Yao, J Y; Chiu, S S

    1987-11-01

    A new type of braided nylon thread with a silver compound coating was made for the purpose of designing a biocidal suture material. The study used standard bacterial culture techniques to evaluate the antibacterial property of the new Ag-coated nylon thread. Seven types of bacterial species were tested; S. aureus, E. coli, P. aeruginosa, K. pneumoniae, S. dysenteriae, S. maruslens, and P. mirabilis. The commercial size 2/0 Nurolon suture from Ethicon served as the control. A weak direct current ranging from 0.4-400 microA was applied to the specimens to examine whether the biocidal property of silver could be enhanced by current. The antibacterial property was evaluated by the width and sterility of the clear zone in the bacterial culture plates. It was found that the new nylon thread exhibited very good to moderate bactericidal property toward these seven bacterial species. P. aeruginosa was the most sensitive species, while P. mirabilis was the least sensitive one. Application of direct current through the Ag-coated specimens positively enhanced their antibacterial property and the degree of enhancement depended on the direct current level. The material also exhibited an antibacterial property toward well-established bacterial colonies, but the effect was less strong than the case when direct current was applied simultaneously with incubation. Silver ions released from the coated nylon thread were responsible for the observed antibacterial property; and the application of a weak direct current to the material enhanced this effect. A preliminary biocompatibility study of this new material in rat gluteal muscle indicated that the new material caused less inflammatory reaction than the control Nurolon suture up to 60 days after implantation. PMID:3316233

  6. A randomised controlled trial comparing skin closure in total knee arthroplasty in the same knee: nylon sutures versus skin staples

    PubMed Central

    Iamthanaporn, K.; Hongnaparak, T.; Tangtrakulwanich, B.

    2016-01-01

    Objectives Nylon sutures and skin staples are used commonly in total knee arthroplasty (TKA) surgical wound closure. However, there is no study that compares the wound healing efficacy and patient satisfaction scores of both techniques in the same knee. Methods We randomised 70 patients who underwent primary TKA into two groups. In one group of 34 patients, the skin at the upper half of the wound was closed with skin staples and the lower half of the wound was closed with simple interrupted nylon sutures. In the other group of 36 patients, the skin at the upper half of the wound was closed with nylon stitches and the lower half of the wound was closed with skin staples. We recorded the wound closure time, pain score at the time of stitch removal, wound complication rate, patient satisfaction score, and the Hollander wound evaluation score at the post-operative periods of five days, 14 days, six weeks, three months, and six months. Each half wound was analysed separately. Results The mean patient body mass index was 26.8 kg/m2 (standard deviation 6.3). A total of 70 nylon stitched wounds and 70 skin stapled wounds were analysed. There were no significant differences in wound complication rates, patient satisfaction score, and the Hollander wound evaluation score between both types of wounds (p > 0.05). The wound closure time for skin stapled wounds was significantly lower than the nylon stitched wounds (p < 0.001). However, the skin stapled wounds had a significantly higher pain score at the time of stitch removal (p < 0.001). Conclusion Skin staples and nylon stitches had comparable results with respect to wound healing and patient satisfaction in TKA wound closure in non-obese patients. The benefit of skin staples over nylon stitches was a decrease in operative time, but was more painful upon removal. Cite this article: V. Yuenyongviwat. A randomised controlled trial comparing skin closure in total knee arthroplasty in the same knee: nylon sutures versus skin

  7. Argon laser suture lysis with different suture materials. An experimental study.

    PubMed Central

    Hugkulstone, C E; Spencer, A F; Vernon, S A

    1994-01-01

    In an in vitro study, 10/0 nylon was found to require a significantly lower laser energy density to produce suture lysis following a single shot than either 10/0 Dacron or 10/0 prolene. Nylon and Dacron monofilament sutures ruptured at reproducible energy levels without significant observable changes at subthreshold irradiation. Prolene, however, was observed to stretch at energy levels below the lysis threshold, under the standard tension produced by a weight of 0.36 (SD 0.02) g. This feature may be of value when performing laser treatment to trabeculectomy flap sutures in the early postoperative period. Images PMID:8025074

  8. Mersilene (polyester), a new suture for penetrating keratoplasty.

    PubMed

    Ramselaar, J A; Beekhuis, W H; Rijneveld, W J; van Andel, M V; Dijk, F; Jongebloed, W L

    1992-01-01

    Mersilene (polyester monofilament) seems to be suitable for penetrating keratoplasty because it is strong, shows no degradation by ultraviolet light, is insoluble, so that it can be left in situ, and offers the possibility of regulating postoperative astigmatism by suture adjustment. In 12 patients penetrating keratoplasty was performed with the combined interrupted/running suturing technique, using eight interrupted nylon 10-0 sutures and one running Mersilene 11-0 suture. The results were compared with those of 25 patients in whom eight interrupted nylon 10-0 sutures and one running nylon 11-0 suture were used. Six months after penetrating keratoplasty, no differences could be found between the two groups in keratometric astigmatism, visual acuity or slitlamp findings. In three patients postoperative adjustment of the running Mersilene suture reduced astigmatism by 50, 90 and 100% respectively. In an animal study the behaviour of Mersilene in the cornea was evaluated by slitlamp examination, histology and electron-microscopy. The tissue response to Mersilene was minimal. Considering the resemblance to nylon in clinical findings, minimal tissue response, lack of biodegradation and possibility of regulating postoperative astigmatism by suture adjustment, Mersilene seems to be a suitable material for penetrating keratoplasty. PMID:1305032

  9. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and...

  10. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and...

  11. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and...

  12. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and...

  13. 21 CFR 878.5020 - Nonabsorbable polyamide surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable polyamide surgical suture. 878.5020 Section 878.5020 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES..., sterile, flexible thread prepared from long-chain aliphatic polymers Nylon 6 and Nylon 6,6 and...

  14. Cranial sutures

    MedlinePlus

    ... Drugs & Supplements Videos & Tools Español You Are Here: Home → Medical Encyclopedia → Cranial sutures URL of this page: //medlineplus.gov/ency/article/002320.htm Cranial sutures To use the sharing features on this page, please enable JavaScript. Cranial sutures ...

  15. A novel postoperative immobilization model for murine Achilles tendon sutures.

    PubMed

    Shibuya, Yoichiro; Takayama, Yuzo; Kushige, Hiroko; Jacinto, Sandra; Sekido, Mitsuru; Kida, Yasuyuki S

    2016-08-01

    The body's motion and function are all in part effected by a vital tissue, the tendon. Tendon injury often results in limited functioning after postoperative procedures and even for a long time after rehabilitation. Although numerous studies have reported surgical procedures using animal models which have contributed to both basic and clinical research, modeling of tendon sutures or postoperative immobilizations has not been performed on small experimental animals, such as mice. In this study we have developed an easy Achilles tendon suture and postoperative ankle fixation model in a mouse. Right Achilles tendons were incised and 10-0 nylons were passed through the proximal and distal ends using a modified Kessler method. Subsequently, the right ankle was immobilized in a plantarflexed position with novel splints, which were made from readily available extension tubes. Restriction of the tendon using handmade splints reduced swelling, as opposed to fixating with the usual plaster of Paris. Using this method, the usage of the right Achilles tendons began on postoperative days 13.5 ± 4.6, which indicated healing within two weeks. Therefore our simple short-term murine Achilles tendon suture procedure is useful for studying immediate tendon repair mechanisms in various models, including genetically-modified mice. PMID:26678297

  16. Otoplasty Outcomes With Different Suture Materials in a Rabbit Model.

    PubMed

    Taylor, Benjamin A; Hong, Paul

    2016-03-01

    Otoplasty is a commonly performed procedure to correct prominent ears. Many different otoplasty techniques have been described but there is no gold standard technique. As well, many different suture materials are used in otoplasty but studies directly comparing different sutures materials are lacking. An otoplasty outcome study with Nylon and Mersilene (2 of the most commonly used sutures in otoplasty) sutures was conducted using a rabbit model. Each rabbit ear was randomized to receive a Mustardé-type horizontal mattress suture with either 4-0 clear Nylon (N = 12 ears) or 4-0 Mersilene sutures (N = 12 ears). Two weeks after surgery, the auricular bend angle was measured with a finger goniometer and histologic analysis with hematoxylin and eosin staining was performed on the rabbit auricular cartilage. Overall, there was no significant difference in the mean bend angle between the 2 groups (Nylon: 135.8°, SD = 22.7° and Mersilene: 143.2°, SD = 19.7°; P = 0.559). Also, no qualitative difference was observed on histologic analysis between the 2 suture groups. In the current rabbit model study, both Nylon and Mersilene sutures performed well and no significant differences were noted. PMID:26967081

  17. Quantitative evaluation of stiffness of commercial suture materials.

    PubMed

    Chu, C C; Kizil, Z

    1989-03-01

    The bending stiffness of 22 commercial suture materials of varying size, chemical structure and physical form was quantitatively evaluated using a stiffness tester (Taber V-5, model 150B, Teledyne). The commercial sutures were Chromic catgut; Dexon (polyglycolic acid); Vicryl (polyglactin 910); PDS (polydioxanone); Maxon (polyglycolide-trimethylene carbonate); Silk (coated with silicone); Mersilene (polyester fiber); Tycron (polyester fiber); Ethibond (polyethylene terephthalate coated with polybutylene); Nurolon (nylon 66); Surgilon (nylon 66 coated with silicone); Ethilon (coated nylon 66), Prolene (polypropylene); Dermalene (polyethylene), and Gore-tex (polytetraflouroethylene). These are both natural and synthetic, absorbable and nonabsorbable and monofilament and multifilament sutures. All of these sutures were size 2-0, but Prolene sutures with sizes ranging from 1-0 to 9-0 were also tested to determine the effect of suture size on stiffness. The bending stiffness data obtained showed that a wide range of bending stiffness was observed among the 22 commercial sutures. The most flexible 2-0 suture was Gore-tex, followed by Dexon, Silk, Surgilon, Vicryl (uncoated), Tycron, Nurolon, Mersilene, Ethibond, Maxon, PDS, Ethilon, Prolene, Chromic catgut, coated Vicryl, and lastly, Dermalene. The large porous volume inherent in Gore-tex monofilament suture was the reason for its lowest flexural stiffness. Sutures with a braided structure were generally more flexible than those of a monofilament structure, irrespective of the chemical constituents. Coated sutures had significantly higher stiffness than the corresponding uncoated ones. This is particularly true when polymers rather than wax were used as the coating material. This increase in stiffness is attributable to the loss of mobility under bending force in the fibers and yarns that make up the sutures. An increase in the size of the suture significantly increased the stiffness, and the magnitude of increase

  18. Astigmatism after cataract surgery: nylon versus Mersilene. Five-year data.

    PubMed

    Drews, R C

    1995-01-01

    This is a follow-up of a previous study that evaluated astigmatism after cataract surgery. In that study with a six-month follow-up, there was no statistically significant difference in astigmatism between eyes with nylon sutures and those with polyester fiber (Mersilene) sutures. This article reports the five-year data on this series of eyes. PMID:7722909

  19. Nylon separators. [thermal degradation

    NASA Technical Reports Server (NTRS)

    Lim, H. S.

    1977-01-01

    A nylon separator was placed in a flooded condition in K0H solution and heated at various high temperatures ranging from 60 C to 110 C. The weight decrease was measured and the molecular weight and decomposition product were analyzed to determine: (1) the effect of K0H concentration on the hydrolysis rate; (2) the effect of K0H concentration on nylon degradation; (3) the activation energy at different K0H concentrations; and (4) the effect of oxygen on nylon degradation. The nylon hydrolysis rate is shown to increase as K0H concentration is decreased 34%, giving a maximum rate at about 16%. Separator hydrolysis is confirmed by molecular weight decrease in age of the batteries, and the reaction of nylon with molecular oxygen is probably negligible, compared to hydrolysis. The extrapolated rate value from the high temperature experiment correlates well with experimental values at 35 degrees.

  20. Sutures - ridged

    MedlinePlus

    ... to show whether the sutures have closed too early. Although your provider keeps records from routine checkups, you may find it helpful to keep your own records of your child's development. Bring these records to your provider's attention if ...

  1. Sutures - separated

    MedlinePlus

    ... of bony plates that allow for growth. The borders where these plates come together are called sutures ... the head Infectious disease work-up, including blood cultures and possible spinal tap Metabolic work-up, such ...

  2. Cranial sutures

    MedlinePlus

    ... by strong, fibrous, elastic tissues called sutures. The spaces between the bones that remain open in babies and young children are called fontanelles. Sometimes, they are called soft spots. These spaces are a part of normal development. The cranial ...

  3. Comparison of vasovasostomy techniques in rats utilizing conventional microsurgical suture, carbon dioxide laser, and fibrin tissue adhesives.

    PubMed

    Ball, R A; Steinberg, J; Wilson, L A; Loughlin, K R

    1993-05-01

    An evaluation of vas reanastomoses in rats comparing suture only, carbon dioxide (CO2) laser-assisted, and fibrin-based tissue adhesive was performed in our laboratory. A cohort of 60 known fertile male Sprague Dawley rats initially underwent lower midline abdominal exploration and transection of their vas deferens bilaterally, followed by immediate microsurgical vasovasostomy by one of the three experimental methods. All groups initially had the severed vasa ends coapted by two or three transmural (mucosa through serosa) sutures of 10-0 nylon under an operating microscope. The conventionally sutured group had an additional four to six nylon 10-0 sutures placed externally in the serosa only to complete the anastomosis. The CO2 laser-assisted group underwent laser welding with denaturation of the serosa to seal the anastomosis. A fibrin-based tissue adhesive, produced by combining human cryoprecipitate and thrombin, was placed topically over the coapted vas ends to seal the anastomosis in the third group. Postoperative evaluation revealed similarities among the three surgical groups with the fibrin-based tissue adhesive group resulting in the highest patency rate (89%) and pregnancy rate (85%) as well as the lowest granulation rate (18%) and shortest operative time (27 minutes). The laser-assisted group resulted in the lowest pregnancy rate (68%), while the sewn anastomosis group had the lowest patency rate (76%). Both laser-assisted and conventionally sewn vasectomy reversals required significantly longer operative time (39 and 46 minutes, respectively) compared with the fibrin-based tissue adhesive-assisted procedures (p < 0.01). This study provides evidence that alternative microsurgical techniques may be utilized to perform uncomplicated, expeditious, and successful vasectomy reversals. PMID:8488619

  4. Elastic behaviour of sutured calf pericardium: influence of the suture threads.

    PubMed

    García Páez, J M; Carrera San Martin, A; García Sestafe, J V; Jorge Herrero, E; Navidad, R; Cordón, A; Castillo-Olivares, J L

    1996-09-01

    The purpose of this study was to assess the elastic behaviour of calf pericardium used in the construction of cardiac bioprosthesis valve leaflets, sutured with different types of commercially available sutures: silk, Gore-Tex, Surgilene and nylon. Thirty-two samples (four series of eight samples each) were subjected to tensile strength testing to breakage. The breaking stress (MPa) ranged between 4.89 MPa for samples sutured with Gore-Tex and 5.22 MPa for those sewn with nylon. Three samples from each series were subjected to a stepwise stress test, involving increasing levels of stress followed by return to zero, to define the elastic limit (the cut-off point beyond which strain is no longer reversible). Analysis of the results provided the mathematical functions that govern the elastic behaviour (stress/strain) within the elastic range for each type of sutured sample. The series sutured with Surgilene presented the highest mean value (1.649 MPa). Finally, a statistical study was carried out to determine which series showed the greatest probability of having the least interaction between the thread and the pericardium. Allowing an interval of +/- 10%, Gore-Tex showed the best probability in this respect. However, real fatigue testing is necessary to definitively determine which is the best suture to use. PMID:8866029

  5. Sutureless and Glue-free Versus Sutures for Limbal Conjunctival Autografting in Primary Pterygium Surgery: A Prospective Comparative Study

    PubMed Central

    Raj, Hans; Gupta, Aditi; Raina, Amit Vikram

    2015-01-01

    Introduction Sutureless and glue-free conjunctival autograft as a treatment modality for primary pterygium is recently gaining popularity but conventional technique of suturing conjunctival autograft is still practised widely. Aim To compare the outcome of sutureless and glue-free technique with sutures for limbal conjunctival autografting in management of primary pterygium. Materials and Methods A prospective interventional study was carried out in 50 consecutive eyes with primary nasal pterygium requiring surgical excision. Simple excision under local anaesthesia was performed followed by closure of the bare sclera by sutureless and glue-free conjunctival autograft in 25 eyes of 25 patients (group 1) and by the conventional method of suturing conjunctival autograft using interrupted 10-0 nylon sutures in 25 eyes of 25 patients (group 2), followed by bandaging for 24 hours in both the groups. Surgical time was recorded for both the techniques. Postoperative discomfort was assessed using preformed questionnaires. The patients were followed up for 6 months. During follow up, graft related complications and recurrence if any were noted. Results Mean surgical time for group 1 (23.20±1.55 minutes) was significantly less as compared to group 2 (37.76±1.89 minutes); (p=0.001). Postoperative symptoms were seen in less number of patients (20%) and were of shorter duration (2 weeks) in group 1 as compared to group 2 with 20 (80%) patients having symptoms lasting for 4 weeks; (p<0.001). Recurrence rate and conjunctival granuloma formation rate for group 1 (0%) and for group 2 (4%) were statistically insignificant. Conclusion Sutureless and glue-free conjunctival autograft technique is simple, easy, safe, effective and less time consuming than sutured limbal autograft technique with less postoperative discomfort and adverse events encountered with the use of suture material. Postoperative results of both techniques are comparable. Hence sutureless and glue-free conjunctival

  6. Tissue reactions to suture materials in the oral mucosa of beagle dogs

    PubMed Central

    Kim, Jae-Seok; Shin, Seung-Il; Herr, Yeek; Park, Joon-Bong; Kwon, Young-Hyuk

    2011-01-01

    Purpose The objective of this study was to compare and evaluate the inflammatory responses of three widely used suture materials in the keratinized gingiva and buccal mucosa of beagle dogs. Methods Silk, polyglycolic acid, and nylon sutures were placed within the mandibular keratinized gingiva and maxillary buccal mucosa of four male beagle dogs. Biopsies were taken 3, 7, and 14 days after suturing. Specimens were prepared with hematoxylin-eosin stain for evaluation under a light microscope. Results The suture materials placed in the oral mucosa elicited more inflammatory reactions than did those placed in the keratinized gingiva. The multifilament suture materials caused more inflammatory tissue reactions than did the monofilament suture materials in the oral mucosa. Conclusions If oral hygiene is well maintained and suture materials are placed in the keratinized gingiva, silk, nylon, and polyglycolic acid are considered to be proper suture materials for oral surgery. However, it is advisable to use monofilament suture materials if the suture site is within the oral mucosa. PMID:21954423

  7. Acid rain degradation of nylon

    SciTech Connect

    Kyllo, K.E.

    1984-01-01

    Acid rain, precipitation with a pH less than 5.6, is known to damage lakes, vegetation and buildings. Degradation of outdoor textiles by acid rain is strongly suspected but not well documented. This study reports the effects of sunlight, aqueous acid, heat and humidity (acid rain conditions) on spun delustered nylon 6,6 fabric. Untreated nylon and nylon treated with sulfuric acid of pH 2.0, 3.0, and 4.4 were exposed to light in an Atlas Xenon-arc fadeometer at 63/sup 0/C and 65% R.H. for up to 640 AATCC Fading Units. The untreated and acid treated nylon fabrics were also exposed to similar temperature and humidity condition without light. Nylon degradation was determined by changes in breaking strength, elongation, molecular weight, color, amino end group concentration (NH/sub 2/) and /sup 13/C NMR spectra. Physical damage was assessed using SEM.

  8. 15 CFR 10.0 - General.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 15 Commerce and Foreign Trade 1 2011-01-01 2011-01-01 false General. 10.0 Section 10.0 Commerce and Foreign Trade Office of the Secretary of Commerce PROCEDURES FOR THE DEVELOPMENT OF VOLUNTARY PRODUCT STANDARDS § 10.0 General. (a) Introduction. The Department of Commerce (hereinafter referred to...

  9. 15 CFR 10.0 - General.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 15 Commerce and Foreign Trade 1 2012-01-01 2012-01-01 false General. 10.0 Section 10.0 Commerce and Foreign Trade Office of the Secretary of Commerce PROCEDURES FOR THE DEVELOPMENT OF VOLUNTARY PRODUCT STANDARDS § 10.0 General. (a) Introduction. The Department of Commerce (hereinafter referred to...

  10. 15 CFR 10.0 - General.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 15 Commerce and Foreign Trade 1 2013-01-01 2013-01-01 false General. 10.0 Section 10.0 Commerce and Foreign Trade Office of the Secretary of Commerce PROCEDURES FOR THE DEVELOPMENT OF VOLUNTARY PRODUCT STANDARDS § 10.0 General. (a) Introduction. The Department of Commerce (hereinafter referred to...

  11. Dynamic observation of biomechanic properties of sciatic nerve at the suture site in rats following repairing.

    PubMed

    Jiang, Baoguo; Zhang, Peixun; Yan, Jiazhi; Zhang, Hongbo

    2008-01-01

    To observe the biomechanic properties of the sciatic nerve at the suture site following repairing in rats. The right sciatic nerves of 40 white Sprague-Dawley 300~350 gm rats were exposed, cut and then repaired with 10-0 nylon sutures with four stitches, laced in the epineurium 0, 1, 3, and 6 weeks after operation, the tensile strength of the sciatic nerves were measured, and the data analyzed statistically. The load elongation curves for both the normal unoperated and operated nerves had similar shape. There were significant differences between the tensile strength of the 0th and the 1st, 3rd, and 6th weeks (P < 0.01). No significant difference was found among the 1st, 3rd, and 6th weeks. The tensile strength of the injured nerves recovered 48% of the normal nerve in the 1st week and 54% in 6 weeks after repairing. It may be concluded that the injured nerves can acquire mostly tensile strength stability in 1 week quickly and can maintain this relative tensile strength stability in 6 weeks. PMID:18293160

  12. Nylon versus polydioxanone in the correction of rectus diastasis.

    PubMed

    Nahas, F X; Augusto, S M; Ghelfond, C

    2001-03-01

    Nylon and polydioxanone are two sutures commonly used to correct rectus diastasis. Polydioxanone, as an absorbable suture, has the advantage of not being palpable in thin patients. Because several forces act against the plication, an absorbable suture would not be efficient in these cases. In this study, two groups of 10 patients each were studied. These patients underwent abdominoplasty and correction of rectus diastasis. In the control group, 2-0 nylon was used to plicate the anterior aponeurosis and 0-polydioxanone was used in the experimental group. The tension of the abdominal wall was measured with a dynamometer in both groups. The width of rectus diastasis was measured 3 cm above and 2 cm below the umbilicus, using a computed tomography (CT) scan before the operation and 3 weeks and 6 months after surgery. The width of rectus diastasis was measured intraoperatively at the same levels. The data were analyzed by Student's t test. Both groups had similar abdominal wall tension on both levels. The diastasis recti was completely corrected at both levels, as confirmed by the 3-week postoperative CT scan and the 6-month CT scan. At the superior level, the width of the rectus diastasis on the preoperative CT scan (2.6 +/- 0.7 cm) was similar to the values obtained intraoperatively (2.7 +/- 0.6 cm), showing no significant statistical difference. At the inferior level, the largest difference between the preoperative CT scan and the intraoperative finding was 0.3 cm. In conclusion, the correction of rectus diastasis with 2-0 nylon and 0-polydioxanone was achieved and maintained after 6 months. CT scans are an accurate method for studying rectus diastasis and other muscles of the abdominal wall. PMID:11304594

  13. Tissue Reactions to Various Suture Materials Used in Oral Surgical Interventions

    PubMed Central

    Javed, Fawad; Al-Askar, Mansour; Almas, Khalid; Romanos, Georgios E.; Al-Hezaimi, Khalid

    2012-01-01

    A variety of suture materials are available for primary wound closure following oral surgical procedures. The aim was to review the tissue reactions to the various suture materials used in oral surgical interventions. Databases were searched using the following keywords: cotton, nylon, polyglecaprone 25, polytetrafluoroethylene (ePTFE), Polyglactin 910, polyglycolic acid (PGA), polylactic acid, silk, surgery, suture, and tissue reaction. Articles published only in English language were included. Seventeen studies were included. Two studies reported that polyglecaprone 25 had positive effects on wound-healing as compared to silk. Six studies reported that silk elicits more intense tissue inflammatory response and delayed wound healing as compared to other suture materials (including ePTFE, polyglecaprone-25, PGA, and nylon). Polyglactin 910 sutures were associated with the development of stitch abscess in one clinical study. Eight studies reported that tissue reactions are minimal with nylon sutures. Tissue reactions to suture materials used for oral surgical interventions may vary depending on the surface properties and bacterial adherence properties of the material. PMID:22645688

  14. Nylon biodegradation by lignin-degrading fungi.

    PubMed Central

    Deguchi, T; Kakezawa, M; Nishida, T

    1997-01-01

    The biodegradation of nylon by lignin-degrading fungi was investigated. The fungus IZU-154 significantly degraded nylon-66 membrane under ligninolytic conditions. Nuclear magnetic resonance analysis showed that four end groups, CHO, NHCHO, CH3, and CONH2, were formed in the biodegraded nylon-66 membranes, suggesting that nylon-66 was degraded oxidatively. PMID:8979361

  15. Adjustable sutures in children.

    PubMed

    Engel, J Mark; Guyton, David L; Hunter, David G

    2014-06-01

    Although adjustable sutures are considered a standard technique in adult strabismus surgery, most surgeons are hesitant to attempt the technique in children, who are believed to be unlikely to cooperate for postoperative assessment and adjustment. Interest in using adjustable sutures in pediatric patients has increased with the development of surgical techniques specific to infants and children. This workshop briefly reviews the literature supporting the use of adjustable sutures in children and presents the approaches currently used by three experienced strabismus surgeons. PMID:24924284

  16. Suture techniques in rhinoplasty.

    PubMed

    Gruber, Ronald P; Chang, Edward; Buchanan, Edward

    2010-04-01

    Suture techniques are an indispensable means to biologically sculpt the cartilage of the nose. Here the authors review their use in tip-plasty and present a 4-suture algorithm that allows for simple, complete control in sculpting the shape of all nasal tips in primary rhinoplasty. After a standard cephalic trim of the lateral crus leaving it 6 mm wide, one or more of the four suture techniques are applied. One of the newest techniques that has yielded excellent results is the hemi-transdomal suture, a variation of the conventional transdomal suture. This technique narrows the dome but also everts the lateral crus slightly to avoid concavities of the nostril rim. The 4-suture algorithm is useful in both the open and closed approaches. A more general use of sutures is described and referred to as the "universal horizontal mattress suture," which can be applied to remove all unwanted convexities or concavities and can be used not only to straighten the cartilage but also strengthen it. This suture has applications for the crooked septum, the collapsed lateral crus (external valve), and the collapsed internal valve, as well as for converting ear cartilage grafts into straighter, stronger grafts than previously thought possible. PMID:20206741

  17. Ureteric Suture Urolithiasis Following Open Emergency Ureteric Repair

    PubMed Central

    Sarmah, Piyush B.; Kelly, Brian D.; Devarajan, Raghuram

    2016-01-01

    Suture urolithiasis is an unusual but recognised phenomenon following surgery on the urinary tract. We report a case in a 30-year-old man who sustained a gunshot injury to the left ureter in Burundi and underwent open ureteric repair in a regional hospital. He migrated to the UK and presented one year later with left loin pain. An intravenous urogram revealed two foci of calcification to the left of L3, within a peri-ureteric position. The patient underwent left-sided ureteroscopy where two calculi each formed around a nylon suture were discovered within a ureteric pseudo-diverticulum, and basketed. This is the first reported case of suture urolithiasis occurring following ureteric surgery. PMID:26989371

  18. RETENTION OF SULFUR DIOXIDE BY NYLON FILTERS

    EPA Science Inventory

    Based on laboratory studies, recovery efficiencies of sulfur dioxide (SO2) were determined for nylon filters. The nylon filters used in these experiments were found to retain SO2. A relatively uniform amount (1.7%) was recoverable from each nylon filter, independent of relative...

  19. Blends of zein and nylon-6

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Blends of zein and nylon-6(55k)were used to produce solution cast films and electrospun fibers. Zein was blended with nylon-6 in formic acid solution. When the amount of nylon-6 was 8% or less a compatible blend formed. The blend was determined to be compatible based on physical property measurement...

  20. GENIE Production Release 2.10.0

    SciTech Connect

    Alam, M.; Andreopoulos, C.; Athar, M.; Bodek, A.; Christy, E.; Coopersmith, B.; Dennis, S.; Dytman, S.; Gallagher, H.; Geary, N.; Golan, T.; Hatcher, R.; Hoshina, K.; Liu, J.; Mahn, K.; Marshall, C.; Morrison, J.; Nirkko, M.; Nowak, J.; Perdue, G. N.; Yarba, J.

    2015-12-25

    GENIE is a neutrino Monte Carlo event generator that simulates the primary interaction of a neutrino with a nuclear target, along with the subsequent propagation of the reaction products through the nuclear medium. It additionally contains libraries for fully-featured detector geometries and for managing various types of neutrino flux. This note details recent updates to GENIE, in particular, changes introduced into the newest production release, version 2.10.0.

  1. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Mineral reinforced nylon resins. 177.2355 Section... Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in... reinforced nylon resins consist of nylon 66, as identified in and complying with the specifications of §...

  2. Underwater robotic suturing.

    PubMed

    Kawaguchi, Masahiko; Shimada, Masanari; Ishikawa, Norihiko; Watanabe, Go

    2016-06-01

    Background Laparoscopic and robotic surgeries have become popular, and this popularity is increasing. However, the environment in which such surgeries are performed is rarely discussed. Similar to arthrosurgery performed in water, artificial ascites could be a new environment for laparoscopic surgery. This study was performed to determine whether robotic surgery is applicable to complicated suturing underwater. Material and methods A da Vinci Surgical System S was used. A weighted fabric sheet was placed at the bottom of a tank. Identical sets were made for each environment: One tank was dry, and the other was filled with water. The suturing task involved placement of a running silk suture around the perimeter of a small circle. The task was performed eight times in each environment. The task time and integrity score were determined. The integrity score was calculated by evaluating accuracy, tightness, thread damage, and uniformity; each factor was evaluated using a five-point scale. Results Although statistically significant differences were not shown in either task time or integrity score between the underwater and air environments, robotic suturing underwater is not inferior to performance in air. Conclusions The feasibility of robotic suturing underwater was confirmed under the herein-described experimental conditions. PMID:26853072

  3. Trabeculectomy with releasable sutures.

    PubMed Central

    Kolker, A E; Kass, M A; Rait, J L

    1993-01-01

    We attempted to reduce some of the postoperative complications of trabeculectomy by using releasable scleral flap sutures. This technique allows an initial tight closure of the scleral flap with the option to increase aqueous humor outflow in the early postoperative period. We reviewed our experience with trabeculectomy and releasable sutures in 146 eyes (134 patients) and compared these cases with a prior series of 128 eyes (124 patients) that underwent trabeculectomy with permanent scleral flap sutures. In the control group, 42 eyes (32.8%) had clinically detectable shallowing of the anterior chamber in the postoperative period. In contrast, shallow anterior chamber was noted in 21 eyes (14.4%) in the group with releasable sutures (P = .0003). Flat anterior chamber, defined as iridocorneal touch to the pupil margin, occurred in 11 control eyes (8.6%) but in only 2 eyes (1.4%) with releasable sutures (P = .0078). Surgical intervention to drain suprachoroidal fluid and re-form the anterior chamber was required in eight control eyes (6.2%) but in only one study eye (0.7%) (P = .014). At 1 year of follow-up, the two groups were similar in terms of mean intraocular pressure, the need for ocular hypotensive medications, and failure rate. PMID:8140688

  4. In vivo and in vitro degradation of monofilament absorbable sutures, PDS and Maxon.

    PubMed

    Metz, S A; Chegini, N; Masterson, B J

    1990-01-01

    Two new absorbable monofilament suture materials polydioxanone and Maxon are being employed increasingly in abdominal surgery because of increased strength retention and decreased tissue reactivity compared with previously available materials. As part of our investigation of the behaviour of suture materials, 3-0 sutures of polydioxanone and Maxon were enclosed in nylon pouches, a technique developed for in vivo experiments to prevent cellular interaction with implanted devices. The pouched sutures were gas sterilized, then implanted in either the extrafascial space or peritoneal cavity for periods of 1-5 wk. Sterilized sutures were also incubated in Ringer's lactate at 37 degrees C. Tensile strength of the exposed sutures was measured. For a given suture material and duration of incubation, there was no significant difference in tensile strength degradation among the three test environments. Although the strength of unexposed Maxon is greater than that of polydioxanone, the residual strength of Maxon decreases more rapidly in use, so that, after 2 wk, the strength of polydioxanone is greater. Scanning electron microscope examination of the suture surfaces reveals that polydioxanone develops surface crazing with time, whereas the surface morphology of Maxon remains relatively unaltered. PMID:2105750

  5. Evaluation of five different suture materials in the skin of the earthworm (Lumbricus terrestris).

    PubMed

    Salgado, Melissa A; Lewbart, Gregory A; Christian, Larry S; Griffith, Emily H; Law, Jerry McHugh

    2014-01-01

    The purpose of this study was to determine which suture material is the most appropriate for dermal closure of terrestrial annelids. This paper describes the tissue reactions of the earthworm, Lumbricus terrestris, to five different types of suture materials in order to determine which suture material is the most appropriate for dermal closure. Silk, monofilament nylon, polydiaxonone, polyglactin 910, and chromic gut were studied. There was mild to moderate tissue reaction to all five suture materials. In all of the biopsies wound-healing reaction consisted of aggregates of blastemal cells which appeared in various stages of dedifferentiation from the body wall. Inflammatory cells infiltrated the wound sites, reminiscent of the typical foreign body reaction in vertebrates. The results indicate polyglactin 910 would be the best suture material with regards to tissue security and reaction scores. Chromic gut occupies the next position but there were problems with suture security over time. This appears to be the first suture material performance study on a terrestrial invertebrate. The earthworm, Lumbricus terrestris, was chosen for its wide availability, size, and the extensive species knowledge base. The earthworm may prove to be a good surgical/suture model for economically important invertebrates such as mollusks, tunicates, and insect larval stages. PMID:25143875

  6. 7. Perineal suturing.

    PubMed

    Blease, Megan; Taylor, Kerry

    2016-04-01

    Preceptorship is the 15th series of 'Midwifery basics' targeted at practising midwives. The aim of these articles is to provide information to raise awareness of the impact of the work of midwives on women's experience, and encourage midwives to seek further information through a series of activities relating to the topic. During the transition from student midwife, the newly qualified practitioner (NQM) is required to obtain experience of perineal suturing. With exposure varying from student to student and inconsistency in teaching methods between hospital trusts, the NQM can be left feeling apprehensive and unsupported to learn this skill. Suturing is a major and sometimes traumatic event for childbearing women, whose experience can vary greatly, depending upon many factors, including environment, skill of those suturing, effective analgesia and waiting times. In this penultimate article of the series, Megan Blease and Kerry Taylor address the current issues and provide learning hints and tips for NQMs learning and practising the skill. PMID:27172679

  7. Nylon cable band reactions in ovariohysterectomized bitches.

    PubMed

    Werner, R E; Straughan, A J; Vezin, D

    1992-01-01

    Nylon cable bands used as ligatures caused postsurgical complications in 5 ovariohysterectomized bitches. Clinical signs included fever, stiffness, strangury, draining fistulae, vaginal discharge, and tenesmus. Most signs first appeared several years after surgery, and all signs were resolved after removal of the bands. On the basis of our experience, we suggest that nylon cable bands not be used for ovariohysterectomy ligations. PMID:1537693

  8. Comparison of CO2 laser welding with suture technique for repair of tendons

    NASA Astrophysics Data System (ADS)

    Popovic, Neven A.; Johnstone, Frederic L.; Kilkelly, Francis X.; McKinney, LuAnn; Van De Merwe, Willem P.; Smith, Allan C.

    1995-05-01

    The purpose of this study was to evaluate the efficacy, histology, and strength of laser welding in repair of sharply transected rat Achilles tendons. In 26 adult, male Sprague-Dawley rats, the severed tendons were repaired with a 7-0 nylon, modified Kessler core suture followed by either a running 9-0 nylon epitendinous suture or a circumferential CO2 laser epidendinous weld using 25% human albumin as a solder. All repairs were timed and post- operative tensile strength was analyzed with material testing equipment. In addition, histologic testing was performed on both types of repairs. The mean time to complete the epitendinous repair in the laser group was 3.5 minutes and in the suture group, 8 minutes. The mean ultimate tensile strength in 6 normal tendons was 40.9 Newtons (N) with group standard deviation of 5.2 N. When compared with normal controls, post-operatively both types of tendon repairs resulted in tensile failure at lower forces. The ultimate tensile strength for the epitendinous suture repair and the laser welds were 13% and 6% of normal controls, respectively. Twenty tendons with epidendinous suture repair had mean ultimate tensile strength of 5.4 (+/- 1.2) N, while the 17 tendons with laser wends failed at 2.6 (+/- 0.9) N. Histologic evaluation of tendons repaired with CO2 laser revealed areas of coagulation and edema on the surface of tendon edges. Post-operatively, greater tissue changes were noted in laser treated tendons than those repaired with sutures. Laser welding of epitenon is possible and can be completed faster than the suture repair. The repaired tendon surface appears smoother and less bulky after laser treatment. However, significantly decreased immediate post-operative strength was demonstrated by the use of Kruskal-Wallis one way analysis of variance and Turkey's pairwise comparison.

  9. Development of lens sutures.

    PubMed

    Kuszak, Jer R; Zoltoski, Rebecca K; Tiedemann, Clifford E

    2004-01-01

    Cylindrical map projections (CMPs) have been used for centuries as an effective means of plotting the features of a 3D spheroidal surfaces (e.g. the earth) on a 2D rectangular map. We have used CMPs to plot primate fiber cell organization from selected growth shells as a function of growth, development and aging. Lens structural parameters and features were derived from slit-lamp, light and transmission and scanning electron micrographs. This information was then used to create CMPs of lenses that were then correlated with azimuthal map projections (AMPs; projections that are radially symmetric around a central point [the poles]) to reveal different suture patterns during distinct time periods. In this manner, both lens fiber and suture branch locations are defined by degrees of longitude and latitude. CMPs and AMPs confirm that throughout defined periods of development, growth and ageing, increasingly complex suture patterns are formed by the precise ordering of straight and opposite end curvature fibers. However, the manner in which additional suture branches are formed anteriorly and posteriorly is not identical. Anteriorly, new branches are added between extant branches. Posteriorly, pairs of new branches are formed that progressively overlay extant branches. The advantage of using CMPs is that the shape and organization of every fiber in a growth shell can be observed in a single image. Thus, the use of CMPs to plot primate fiber cell organization has revealed more complex aspects of fiber formation that may explain, at least in part, changes in lens optical quality as a function of age and pathology. In addition, more accurate measurements of fiber length will be possible by incorporating the latitudinal and longitudinal locations of fibers. PMID:15558480

  10. Purification of caprolactam from recycled nylon

    SciTech Connect

    Moens, L.

    1999-07-06

    A method is disclosed of removing 1,11-diamino-6-undecanone from the pyrolysis product of nylon comprising: (a) pyrolyzing nylon-6 to form a pyrolyzate containing a caprolactam mixture; (b) dissolving the caprolactam mixture in a solvent to form a solution; (c) passing carbon dioxide gas through the solution to form a precipitate; (d) removing the precipitate from the solution; and (e) recovering the purified caprolactam from the solution. 3 figs.

  11. Purification of caprolactam from recycled nylon

    SciTech Connect

    Moens, Luc

    1999-01-01

    A method of removing 1,11-diamino-6-undecanone from the pyrolysis product of nylon comprising: a) pyrolyzing nylon-6 to form a pyrolyzate containing a caprolactam mixture; b) dissolving the caprolactam mixture in a solvent to form a solution; c) passing carbon dioxide gas through the solution to form a precipitate; d) removing the precipitate from the solution; and e) recovering the purified caprolactam from the solution.

  12. Evaluation of the effect of 4 types of knots on the mechanical properties of 4 types of suture material used in small animal practice.

    PubMed

    Avoine, Xytilis; Lussier, Bertrand; Brailovski, Vladimir; Inaekyan, Karine; Beauchamp, Guy

    2016-04-01

    The influence of the type of material used, knot configuration, and use of an additional throw on the tensile force at failure, the elongation, and the mode of failure of different configurations of linear sutures and knotted suture loops was evaluated in this in-vitro mechanical study. We hypothesized that all types of knots would significantly influence the initial force and elongation of suture materials and would influence the force and elongation at which the knotted loops break, but not their mode of failure. A total of 432 samples of 4 types of size 3-0 suture material (polydioxanone, polyglecaprone 25, polyglactin 910, and nylon), representing 9 configurations, were tested in a tensiometer. The configurations were 1 linear suture without a knot and the following loops: square (SQ) knot; surgeon's (SU) knot; granny (GR) knot; and sliding half-hitch (SHH) knot using either 4 and 5 or 3 and 4 throws, depending on the material. For polydioxanone, SQ and SU knots did not decrease the initial force at failure of the suture. Granny (GR) and SHH knots decreased the tensile force at failure and elongation by premature failure of the loop. For polyglecaprone 25, all knots decreased the initial force at failure of the suture, with SHH being weaker than the other knots. For coated polyglactin 910, all knots decreased the initial force at failure of the suture and slippage increased significantly compared with the other 3 sutures. The use of SQ knots with 3 throws did not result in a safe knot. For nylon, knots did not alter the original mechanics of the suture. In conclusion, all knots and types of suture material do not necessarily have the same effect on the initial tensile force at failure of suture materials. PMID:27127344

  13. Sliding Wear Properties of HVOF Thermally Sprayed Nylon-11 and Nylon-11/Ceramic Composites on Steel

    NASA Astrophysics Data System (ADS)

    Jackson, L.; Ivosevic, M.; Knight, R.; Cairncross, R. A.

    2007-12-01

    Polymer and polymer/ceramic composite coatings were produced by ball-milling 60 μm Nylon-11 together with nominal 10 vol.% of nano and multiscale ceramic reinforcements and by HVOF spraying these composite feedstocks onto steel substrates to produce semicrystalline micron and nanoscale reinforced polymer matrix composites. Room temperature dry sliding wear performance of pure Nylon-11, Nylon-11 reinforced with 7 nm silica, and multiscale Nylon-11/silica composite coatings incorporating 7-40 nm and 10 μm ceramic particles were characterized using a pin-on-disk tribometer. Coefficient of friction and wear rate were determined as a function of applied load and coating composition. Surface profilometry and scanning electron microscopy were used to characterize and analyze the coatings and wear scars. The pure Nylon-11 coating experienced less wear than the composites due to the occurrence of two additional wear mechanisms: abrasive and fatigue wear.

  14. 38 CFR 10.0 - Adjusted service pay entitlements.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2014-07-01 2014-07-01 false Adjusted service pay entitlements. 10.0 Section 10.0 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUSTED COMPENSATION Adjusted Compensation; General § 10.0 Adjusted service pay entitlements. A veteran entitled...

  15. 38 CFR 10.0 - Adjusted service pay entitlements.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2012-07-01 2012-07-01 false Adjusted service pay entitlements. 10.0 Section 10.0 Pensions, Bonuses, and Veterans' Relief DEPARTMENT OF VETERANS AFFAIRS ADJUSTED COMPENSATION Adjusted Compensation; General § 10.0 Adjusted service pay entitlements. A veteran entitled...

  16. CXCL12/CXCR4 axis regulates neovascularization and lymphangiogenesis in sutured corneas in mice

    PubMed Central

    DU, LING-LING; LIU, PING

    2016-01-01

    The present study aimed to determine the plausible functional role of chemokine (C-X-C motif) ligand 12 (CXCL12)/chemokine (C-X-C motif) receptor 4 (CXCR4) in inflammatory corneal hemangiogenesis and lymphangiogenesis in vivo. Corneal hemangiogenesis and lymphangiogenesis were induced by placing an 11-0 nylon suture in an intrastromal position. The expression levels of the vascular endothelial growth factor (VEGF) family, CXCL12 and CXCR4 in the corneas were investigated in the corneas using reverse transcription-quantitative polymerase chain reaction and immunohistochemistry. Corneal hemangiogenic and lymphangiogenic responses were assessed by immunofluorescence using specific antibodies against cluster of differentiation 31 and lymphatic vessel endothelial hyaluronan receptor-1. Subconjunctival injection of AMD3100 to the sutured corneas was also performed. CXCL12/CXCR4 mRNA and protein expression levels increased markedly in suture-induced corneal neovascularization (CNV) and decreased with AMD3100 treatment. Hemangiogenesis and lymphangiogenesis were captured in images using immunofluorescence and were shown to be markedly increased with suture placement and reduced with AMD3100 treatment. VEGF-A/VEGFR-1 and VEGF-C/VEGFR-3 mRNA expression levels were upregulated in the suture placement and control groups, whereas the expression levels of all the factors were downregulated in the AMD3100 treatment group. The results from the present study demonstrated that CXCL12/CXCR4 interactions regulate hemangiogenesis and lymphangiogenesis in suture-induced CNV. AMD3100 may be a novel therapeutic target for the prevention of blindness. PMID:27121088

  17. Fabrication of nylon-6/carbon nanotube composites

    NASA Astrophysics Data System (ADS)

    Xu, C.; Jia, Z.; Wu, D.; Han, Q.; Meek, T.

    2006-05-01

    A new technique to fabricate nylon-6/carbon nanotube (PA6/CNT) composites is presented. The method involves a pretreatment of carbon nanotubes synthesized by catalytic pyrolysis of hydrocarbon and an improved in-situ process for mixing nanotubes with the nylon 6 matrix. A good bond between carbon nanotubes and the nylon-6 matrix is obtained. Mechanical property measurements indicate that the tensile strength of PA6/CNT composites is improved significantly while the toughness and elongation are somewhat compromised. Scanning electron microscopy (SEM) analysis of the fractured tensile specimens reveals cracking initiated at the wrapping of the CNTs PA6 layer/PA6 matrix interface rather than at the PA6/CNT interface.

  18. Nylon Dissolution in Nitric Acid Solutions

    SciTech Connect

    KESSINGER, GLENF.

    2004-06-16

    H Area Operations is planning to process Pu-contaminated uranium scrap in support of de-inventory efforts. Nylon bags will be used to hold materials to be dissolved in H-Canyon. Based on this set of twelve nylon dissolutions, it is concluded that (when other variables are held constant): increased acid concentration results in increased dissolution rates; increased acid concentration results in a lower dissolution onset temperature; little, if any, H plus is consumed during the depolymerization process; and 2.0-3.0 M HNO3, with 0.025 M KF and 2 g/L B, is satisfactory for the dissolution of nylon bag materials to be used during H-Canyon processing.

  19. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as...

  20. Maintenance Manual for Carpets Made with Du Pont Carpet Nylon.

    ERIC Educational Resources Information Center

    Du Pont Corp., Wilmington, DE.

    Information is divided into the following sections--(1) the selection of nylon carpet, (2) the advantages of nylon for carpets, (3) the characteristics of nylon carpet, (4) soiling and soil retardants, (5) vacuum cleaning, (6) spot cleaning and freshening of traffic lanes, (7) wet cleaning (shampooing), and (8) miscellaneous carpet maintenance…

  1. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as...

  2. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as...

  3. 21 CFR 177.2355 - Mineral reinforced nylon resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Mineral reinforced nylon resins. 177.2355 Section... as Components of Articles Intended for Repeated Use § 177.2355 Mineral reinforced nylon resins. Mineral reinforced nylon resins identified in paragraph (a) of this section may be safely used as...

  4. Nylon screws make inexpensive coil forms

    NASA Technical Reports Server (NTRS)

    Aucoin, G.; Rosenthal, C.

    1978-01-01

    Standard nylon screws act as coil form copper wire laid down in spiral thread. Completed coil may be bonded to printed-circuit board. However, it is impossible to tune coil by adjusting spacing between windings, technique sometimes used with air-core coils.

  5. Arthroscopic Suture Anchor Tenodesis: Loop-Suture Technique

    PubMed Central

    Shon, Min Soo; Koh, Kyoung Hwan; Lim, Tae Kang; Lee, Seung Won; Park, Young Eun; Yoo, Jae Chul

    2013-01-01

    With advancements in arthroscopic surgery, arthroscopic biceps tenodesis with suture anchor recently has been reported to be a reasonable option for the treatment of biceps pathologies, especially for those that are symptomatic or accompanied by a rotator cuff tear. We introduce our technique of arthroscopic biceps tenodesis with suture anchor that we call the loop-suture technique, which is constructed with 1 loop strand and another sutured strand. This technique can help to improve biceps grip and simultaneously minimize longitudinal splitting of the tendon. In addition, it is relatively simple and can be performed with the use of conventional devices and arthroscopic portals used for rotator cuff repair, without the formation of additional portals or a separate incision for the tenodesis. PMID:23875133

  6. Arthroscopic suture anchor tenodesis: loop-suture technique.

    PubMed

    Shon, Min Soo; Koh, Kyoung Hwan; Lim, Tae Kang; Lee, Seung Won; Park, Young Eun; Yoo, Jae Chul

    2013-05-01

    With advancements in arthroscopic surgery, arthroscopic biceps tenodesis with suture anchor recently has been reported to be a reasonable option for the treatment of biceps pathologies, especially for those that are symptomatic or accompanied by a rotator cuff tear. We introduce our technique of arthroscopic biceps tenodesis with suture anchor that we call the loop-suture technique, which is constructed with 1 loop strand and another sutured strand. This technique can help to improve biceps grip and simultaneously minimize longitudinal splitting of the tendon. In addition, it is relatively simple and can be performed with the use of conventional devices and arthroscopic portals used for rotator cuff repair, without the formation of additional portals or a separate incision for the tenodesis. PMID:23875133

  7. Current applications of endoscopic suturing

    PubMed Central

    Stavropoulos, Stavros N; Modayil, Rani; Friedel, David

    2015-01-01

    Endoscopic suturing had previously been considered an experimental procedure only performed in a few centers and often by surgeons. Now, however, endoscopic suturing has evolved sufficiently to be easily implemented during procedures and is more commonly used by gastroenterologists. We have employed the Apollo OverStitch suturing device in a variety of ways including closure of perforations, closure of full thickness defects in the gastrointestinal wall created during endoscopic full thickness resection, closure of mucosotomies during peroral endoscopic myotomy, stent fixation, fistula closure, post endoscopic submucosal dissection, endoscopic mucosal resection and Natural Orifice Transluminal Endoscopic Surgery defect closures, post-bariatric surgery gastrojejunal anastomosis revision and primary sleeve gastroplasty. PMID:26191342

  8. Craniosynostosis of the lambdoid suture.

    PubMed

    Rhodes, Jennifer L; Tye, Gary W; Fearon, Jeffrey A

    2014-08-01

    Craniosynostosis affecting the lambdoid suture is uncommon. The definition of lambdoid craniosynostosis solely applies to those cases demonstrating true suture obliteration, similar to other forms of craniosynostosis. In patients presenting with posterior plagiocephaly, true lambdoid craniosynostosis must be differentiated from the much more common positional molding. It can occur in a unilateral form, a bilateral form, or as part of a complex craniosynostosis. In children with craniofacial syndromes, synostosis of the lambdoid suture most often is seen within the context of a pansynostotic picture. Chiari malformations are commonly seen in multisutural and syndromic types of craniosynostosis that affect the lambdoid sutures. Posterior cranial vault remodeling is recommended to provide adequate intracranial volume to allow for brain growth and to normalize the skull shape. Although many techniques have been described for the correction of lambdoid synostosis, optimal outcomes may result from those techniques based on the concept of occipital advancement. PMID:25210507

  9. Craniosynostosis of the Lambdoid Suture

    PubMed Central

    Rhodes, Jennifer L.; Tye, Gary W.; Fearon, Jeffrey A.

    2014-01-01

    Craniosynostosis affecting the lambdoid suture is uncommon. The definition of lambdoid craniosynostosis solely applies to those cases demonstrating true suture obliteration, similar to other forms of craniosynostosis. In patients presenting with posterior plagiocephaly, true lambdoid craniosynostosis must be differentiated from the much more common positional molding. It can occur in a unilateral form, a bilateral form, or as part of a complex craniosynostosis. In children with craniofacial syndromes, synostosis of the lambdoid suture most often is seen within the context of a pansynostotic picture. Chiari malformations are commonly seen in multisutural and syndromic types of craniosynostosis that affect the lambdoid sutures. Posterior cranial vault remodeling is recommended to provide adequate intracranial volume to allow for brain growth and to normalize the skull shape. Although many techniques have been described for the correction of lambdoid synostosis, optimal outcomes may result from those techniques based on the concept of occipital advancement. PMID:25210507

  10. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    .... Nylon 6/69 resins for use only as specified in 21 CFR 177.1395 of this chapter 1.09±0.02 270-277 >140..., see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume... apparatus. The use of crossed nicol prisms with a microscope hot stage and reading of the thermometer...

  11. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    .... Nylon 6/69 resins for use only as specified in 21 CFR 177.1395 of this chapter 1.09±0.02 270-277 >140..., see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume... apparatus. The use of crossed nicol prisms with a microscope hot stage and reading of the thermometer...

  12. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    .... Nylon 6/69 resins for use only as specified in 21 CFR 177.1395 of this chapter 1.09±0.02 270-277 >140..., see the List of CFR Sections Affected, which appears in the Finding Aids section of the printed volume... apparatus. The use of crossed nicol prisms with a microscope hot stage and reading of the thermometer...

  13. 21 CFR 177.1500 - Nylon resins.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    .... Nylon 6/69 resins for use only as specified in 21 CFR 177.1395 of this chapter 1.09±0.02 270-277 >140... approximately the size of the molding powder. This can be done conveniently by using a small-scale commercial... while still hot, using a Buchner funnel approximately 5 inches in diameter, a suction flask, and...

  14. Purification and Characterization of a Nylon-Degrading Enzyme

    PubMed Central

    Deguchi, Tetsuya; Kitaoka, Yoshihisa; Kakezawa, Masaaki; Nishida, Tomoaki

    1998-01-01

    A nylon-degrading enzyme found in the extracellular medium of a ligninolytic culture of the white rot fungus strain IZU-154 was purified by ion-exchange chromatography, gel filtration chromatography, and hydrophobic chromatography. The characteristics of the purified protein (i.e., molecular weight, absorption spectrum, and requirements for 2,6-dimethoxyphenol oxidation) were identical to those of manganese peroxidase, which was previously characterized as a key enzyme in the ligninolytic systems of many white rot fungi, and this result led us to conclude that nylon degradation is catalyzed by manganese peroxidase. However, the reaction mechanism for nylon degradation differed significantly from the reaction mechanism reported for manganese peroxidase. The nylon-degrading activity did not depend on exogenous H2O2 but nevertheless was inhibited by catalase, and superoxide dismutase inhibited the nylon-degrading activity strongly. These features are identical to those of the peroxidase-oxidase reaction catalyzed by horseradish peroxidase. In addition, α-hydroxy acids which are known to accelerate the manganese peroxidase reaction inhibited the nylon-degrading activity strongly. Degradation of nylon-6 fiber was also investigated. Drastic and regular erosion in the nylon surface was observed, suggesting that nylon is degraded to soluble oligomers and that nylon is degraded selectively. PMID:9546174

  15. U10.0 Undulator conceptual design report

    SciTech Connect

    Hoyer, E.

    1994-06-01

    The U10.0 Undulator described here is a 43 period, 10 cm period, 4.5 meter long insertion device. Designed for the Advanced Light Source (ALS) storage ring at the Lawrence Berkeley Laboratory. This insertion device will provide high brightness, quasi-monochromatic radiation in the 5-950 eV energy range. This conceptual design report includes sections on: parameter development, spectral performance, and accelerator requirements, physics specifications and the detailed conceptual design of the magnetic structure, the support/drive systems, the insertion device control system, the vacuum system, and installation for the U10.0 Undulator.

  16. Neogene sutures in eastern Indonesia

    NASA Astrophysics Data System (ADS)

    Hall, R.; Wilson, M. E. J.

    2000-12-01

    Five suture zones are described from the zone of collision between the Eurasian, Indian-Australian and Pacific-Philippine Sea plates within the eastern Indonesia region. These are the Molucca, Sorong, Sulawesi, Banda and Borneo sutures. Each of these sutures has a relatively short history compared to most pre-Neogene orogenic belts, but each preserves a record of major changes in tectonics including subduction polarity reversals, elimination of volcanic arcs, changing plate boundaries, and important extension within an overall contractional setting. Rapid tectonic changes have occurred within periods of less than 5 Ma. Many of these events, although important, would be overlooked in older orogenic belts because the age resolution required to identify them, even when the evidence is preserved, is simply not possible.

  17. 38 CFR 10.0 - Adjusted service pay entitlements.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2011-07-01 2011-07-01 false Adjusted service pay... COMPENSATION Adjusted Compensation; General § 10.0 Adjusted service pay entitlements. A veteran entitled to adjusted service pay is one whose adjusted service credit does not amount to more than $50 as...

  18. 38 CFR 10.0 - Adjusted service pay entitlements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 38 Pensions, Bonuses, and Veterans' Relief 1 2010-07-01 2010-07-01 false Adjusted service pay... COMPENSATION Adjusted Compensation; General § 10.0 Adjusted service pay entitlements. A veteran entitled to adjusted service pay is one whose adjusted service credit does not amount to more than $50 as...

  19. Absorption of water and lubricating oils into porous nylon

    NASA Technical Reports Server (NTRS)

    Bertrand, P. A.

    1995-01-01

    Oil and water absorption from air into sintered porous nylon can be described by infiltration into the pores of the material. This process can be modeled by a diffusion-like mechanism. For water absorption, we find a formal diffusion coefficient of 1.5 x 10(exp -4)sq cm/min when the nylon is initially dry. The diffusion coefficient is 4 x 10(exp -6)sq cm/min when the nylon is oil-impregnated prior to air exposure. In a 52% RH atmosphere, dry nylon absorbs 3% w/w water, and oil-impregnated nylon absorbs 0.6% w/w water. For oil absorption there are three steps: (1) surface absorption and infiltration into (2) larger and (3) smaller pores. Surface absorption is too fast to be measured in these experiments. The diffusion coefficient for the second step is 6 x 10(exp -4)sq cm/min for SRG-60 oil into dry nylon and 4 x 10(exp -4)sq cm/min for air-equilibrated nylon. The diffusion coefficient for the third step is about 1 x 10(exp -6)sq cm/min for both cases. The total amount of oil absorbed is 31% w/w. The interaction between water and nylon is not as strong as that between water and cotton-phenolic: oil can replace water, and only a small amount of water can enter previously oil-impregnated nylon.

  20. A modified suture placement technique to avoid suture drag or "cheese wire" effect.

    PubMed

    Cravy, T V

    1980-05-01

    A modified technique is described for microsurgical suture placement, irrespective of the closure technique, to prevent suture drag and loosening of the suture following postoperative wound edema. Fine, elastic, non-absorbable sutures which loosen as a result of suture drag or "cheese wiring" have no more reliability than do absorbable or silk sutures. Predictable and reproducible results of suture placement are necessary to allow the surgeon to effectively use the operating keratometer in the control and modification of corneal astigmatism following anterior segment surgery. PMID:6992018

  1. Classroom Illustrations of Acidic Air Pollution Using Nylon Fabric

    ERIC Educational Resources Information Center

    Campbell, Dean J.; Wright, Emily A.; Dayisi, Mardhia O.; Hoehn, Michael R.; Kennedy, Branden F.; Maxfield, Brian M.

    2011-01-01

    In 1970, deposition of fly ash from a coal burning power plant in downtown Peoria produced minor damage in the vicinity of its smokestack, including runs in ladies nylon stockings. In this article, we review the historical event and discuss the chemistry behind the depolymerization of the nylon, as well as laboratory experiments demonstrating how…

  2. Suture materials - Current and emerging trends.

    PubMed

    Dennis, Christopher; Sethu, Swaminathan; Nayak, Sunita; Mohan, Loganathan; Morsi, Yosry Yos; Manivasagam, Geetha

    2016-06-01

    Surgical sutures are used to facilitate closure and healing of surgical- or trauma-induced wounds by upholding tissues together to facilitate healing process. There is a wide range of suture materials for medical purpose and the main types include absorbable and nonabsorbable. Recently, there is a growth in the development of classes of suture materials based on their properties and capabilities to improve tissue approximation and wound closure. This review outlines and discusses the current and emerging trends in suture technology including knotless barbed sutures, antimicrobial sutures, bio-active sutures such as drug-eluting and stem cells seeded sutures, and smart sutures including elastic, and electronic sutures. These newer strategies expand the versatility of sutures from being used as just a physical entity approximating opposing tissues to a more biologically active component enabling delivery of drugs and cells to the desired site with immense application potential in both therapeutics and diagnostics. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 1544-1559, 2016. PMID:26860644

  3. Cellular interactions and stimulated biological functions mediated by nanostructured carbon for tissue reconstruction and tracheal tubes and sutures.

    PubMed

    Misra, R D K; Chaudhari, P M

    2013-02-01

    Nylon 6,6 is used for biological applications including gastrointestinal segments, tracheal tubes and sutures, vascular graft, and for hard tissue reconstruction. While it is a relatively inexpensive polymer, it is not widely acceptable as a preferred biomaterial because of bioactivity. To this end, we have discovered the exciting evidence that introduction of a novel nanostructured carbon, graphene, in the void space between the nylon chains and processing at elevated pressure favorably stimulates cellular functions and provides high degree of cytocompatibility. The cell-substrate interactions on stand alone Nylon 6,6 and Nylon 6,6-graphene oxide hybrid system were investigated in terms of cell attachment, viability, proliferation, and assessment of proteins, actin, vinculin, and fibronectin. The enhanced biological functions in the nanostructured hybrid system are attributed to relatively superior hydrophilicity of the surface and to the presence of graphene. Furthermore, it is proposed that the negatively charged graphene interacts with the polar nature of cells and the culture medium, such that the interaction is promoted through polar forces. This is accomplished by investigating cell attachment, proliferation, and morphology, including cytomorphometry evaluation, and quantitative assessment of prominent proteins, actin, vinculin, and fibronectin that are sensitive to cell-substrate interactions. Osteoblasts were studied to establish the practical viability of the hybrid nanostructured biomaterial. The study strengthens the foundation for utilizing nano- or quantum-size effects of nanostructured biomaterials. PMID:22927360

  4. Experimental investigation on the mechanical properties of glass fiber reinforced nylon

    NASA Astrophysics Data System (ADS)

    Nuruzzaman, D. M.; Iqbal, A. K. M. Asif; Oumer, A. N.; Ismail, N. M.; Basri, S.

    2016-02-01

    In this study, the influence of different weight percentages of glass fiber (GF) reinforcement on the mechanical properties of nylon (PA6) composite is investigated. Test specimens of pure nylon, 95% nylon + 5% GF, 90% nylon + 10% GF, 85% nylon + 15% GF and 80% nylon + 20% GF are prepared using an injection molding machine. In the experiments, tensile tests and impact tests are carried out. The obtained results reveal that mechanical properties of the nylon composites are significantly influenced by the weight percentage of glass fiber. From the tensile test results, it is observed that pure nylon has the lowest elastic modulus and yield strength whereas 80% nylon + 20% GF composite shows the highest elastic modulus and yield strength. Moreover, pure nylon shows the lowest tensile strength while 80% nylon + 20% GF shows significantly improved tensile strength. Results show that elongation at break is remarkably high for pure nylon whereas it is very low for 80% nylon + 20% GF. Izod impact test results reveal that, 85% nylon + 15% GF composite has the highest impact strength or toughness whereas 95% nylon + 5% GF composite shows the lowest impact strength. Furthermore, 80% nylon + 20% GF composite shows somewhat less impact strength or toughness than 85% nylon + 15% GF composite.

  5. Nylon-muscle-actuated robotic finger

    NASA Astrophysics Data System (ADS)

    Wu, Lianjun; Jung de Andrade, Monica; Rome, Richard S.; Haines, Carter; Lima, Marcio D.; Baughman, Ray H.; Tadesse, Yonas

    2015-04-01

    This paper describes the design and experimental analysis of novel artificial muscles, made of twisted and coiled nylon fibers, for powering a biomimetic robotic hand. The design is based on circulating hot and cold water to actuate the artificial muscles and obtain fast finger movements. The actuation system consists of a spring and a coiled muscle within a compliant silicone tube. The silicone tube provides a watertight, expansible compartment within which the coiled muscle contracts when heated and expands when cooled. The fabrication and characterization of the actuating system are discussed in detail. The performance of the coiled muscle fiber in embedded conditions and the related characteristics of the actuated robotic finger are described.

  6. Tram-Track Suture Technique for Pupillary Capture of a Scleral Fixated Intraocular Lens

    PubMed Central

    Kim, Sung In; Kim, Kiseok

    2016-01-01

    Purpose To report a new technique using tram-track suture for pupillary capture of a scleral fixated posterior chamber intraocular lens (PC-IOL) to reposition the tilted IOL. Methods In this prospective interventional case series, we describe a tram-track suture for pupillary capture of a scleral fixated PC-IOL. A long straight needle with double-armed 10-0 polypropylene is passed behind the iris and just above the optic portion (tilted forward) of the IOL. The other straight needle with double-armed 10-0 polypropylene is passed just below the optic portion (tilted backward) of the IOL. After the IOL is repositioned properly, the polypropylene sutures are gently pulled and tied. Results Four eyes of 4 patients underwent tram-track suture for pupillary capture of a scleral fixated PC-IOL. No intra- or postoperative complications were noted, and no pupillary captures were detected during the follow-up period. Conclusions The tram-track suture technique provides good centration and stability of a PC-IOL. This technique is an easy and effective way to reposition pupillary capture of an IOL. Further, it is also minimally invasive as it maintains a closed system. PMID:27462257

  7. Modified Open-Door Laminoplasty Using a Ceramic Spacer and Suture Fixation for Cervical Myelopathy

    PubMed Central

    Toyone, Tomoaki; Shiboi, Ryutaro; Inada, Kunimasa; Oikawa, Yasuhiro; Takahashi, Kazuhisa; Ohtori, Seiji; Inoue, Gen; Miyagi, Masayuki; Ishikawa, Tetsuhiro; Shirahata, Toshiyuki; Kudo, Yoshifumi; Inagaki, Katsunori

    2015-01-01

    Purpose To introduce a new simple technique using suture anchors and ceramic spacers to stabilize the elevated laminae in open-door cervical laminoplasty. Although ceramic spacers were placed in the opened laminae and fixed with nylon threads in this series, it was occasionally difficult to fix the nylon threads to the lateral mass. Materials and Methods Study 1: A preliminary study was conducted using a suture anchor system. Sixteen consecutive patients who underwent surgery for cervical myelopathy were prospectively examined. Study 2: The second study was performed prospectively to evaluate the feasibility of this new technique based on the result of the preliminary study. Clinical outcomes were examined in 45 consecutive patients [cervical spondylotic myelopathy (CSM)] and 43 consecutive patients (OPLL). The Japanese Orthopedic Association scoring system (JOA score), axial neck pain, and radiological findings were analyzed. Results 1) In one case, re-operation was necessary due to dislodgement of the ceramic spacer following rupture of the thread. 2) In all patients, postoperative CT scans showed that the anchors were securely inserted into the bone. In the CSM group, the average JOA score improved from 9.5 points preoperatively to 13.3 at follow-up (recovery 51%). In the OPLL group, the average JOA score improved from 10.1 (5-14) points preoperatively to 14.4 (11-16) at follow-up (recovery 62%). There were no serious complications. Conclusion The use of the suture anchor system made it unnecessary to create a hole in the lateral mass and enabled reliable and faster fixation of the HA spacers in open-door laminoplasty. PMID:26446650

  8. Terminal Area Simulation System User's Guide - Version 10.0

    NASA Technical Reports Server (NTRS)

    Switzer, George F.; Proctor, Fred H.

    2014-01-01

    The Terminal Area Simulation System (TASS) is a three-dimensional, time-dependent, large eddy simulation model that has been developed for studies of wake vortex and weather hazards to aviation, along with other atmospheric turbulence, and cloud-scale weather phenomenology. This document describes the source code for TASS version 10.0 and provides users with needed documentation to run the model. The source code is programed in Fortran language and is formulated to take advantage of vector and efficient multi-processor scaling for execution on massively-parallel supercomputer clusters. The code contains different initialization modules allowing the study of aircraft wake vortex interaction with the atmosphere and ground, atmospheric turbulence, atmospheric boundary layers, precipitating convective clouds, hail storms, gust fronts, microburst windshear, supercell and mesoscale convective systems, tornadic storms, and ring vortices. The model is able to operate in either two- or three-dimensions with equations numerically formulated on a Cartesian grid. The primary output from the TASS is time-dependent domain fields generated by the prognostic equations and diagnosed variables. This document will enable a user to understand the general logic of TASS, and will show how to configure and initialize the model domain. Also described are the formats of the input and output files, as well as the parameters that control the input and output.

  9. Suturing a tear of the anterior capsulorhexis

    PubMed Central

    Kleinmann, G; Chew, J; Apple, D J; Assia, E I; Mamalis, N

    2006-01-01

    Aim To describe a new technique of suturing a tear in the anterior capsulorhexis. Methods Continuous curvilinear capsulorhexis (CCC) with lens removal was done in five fresh cadaver eyes. The diameter of the CCC was measured with a calliper. Using the same calliper a tear of the CCC was created while opening the calliper's arms. The distance between the calliper's arms needed to tear the CCC was documented. Using 9‐0 Ethilon 9011, CS 160‐6 sutures in two eyes, 9‐0 Prolene, D‐8229, CTC‐6L sutures in two eyes, and 10‐0 Prolene, 9090, CTC‐6 suture in one eye, the tears were sutured. A tear in the CCC was created again in the same way as the first tear. The distance between the calliper's arms needed to tear the CCC was documented again. Results Suturing of the tear restored some of the strength/elasticity of the CCC. Better results were found while using the 9‐0 Prolene, D‐8229, CTC‐6L sutures than with the two others sutures. Conclusions Suturing of a broken CCC can restore at least some of the strength/elasticity of the CCC. This can be important before intraocular lens (IOL) implantation for the safety of the implantation or after the implantation to ensure proper fixation of the IOL. PMID:16547318

  10. Comparison of ultrasonic suture welding and traditional knot tying in a rabbit rotator cuff repair model.

    PubMed

    Nho, Shane J; Cole, Brian J; Mazzocca, Augustus D; Williams, James M; Romeo, Anthony A; Bush-Joseph, Charles A; Bach, Bernard R; Hallab, Nadim J

    2006-01-01

    The purpose of this study is to evaluate ultrasonic suture welding of monofilament suture in an animal model of rotator cuff repair with biomechanical and histologic analyses. We randomly assigned 46 shoulders in 23 rabbits to 1 of 3 treatment groups: sham-operated (n = 15), knotted (n = 15), and welded (n = 16). Supraspinatus defects were surgically created and acutely repaired with suture anchors loaded with either No. 2-0 Ethibond for knotted group or No. 2-0 nylon for welded shoulders. Eighteen weeks postoperatively, all animals were killed, and the shoulders underwent either biomechanical testing or histologic analysis. The maximum stress of the sham-operated group (20.6 N/mm2) was significantly greater than that of both the knotted (10.2 N/mm2) and welded (8.3 N/mm2) groups (P < .05), but no differences were observed between the knotted and welded groups. Although some histologic changes were noted, none was considered to be significant to distinguish either group. PMID:16979062

  11. Suture materials affect peri-implant bone healing and implant osseointegration.

    PubMed

    Villa, Oscar; Lyngstadaas, Staale P; Monjo, Marta; Satué, Maria; Rønold, Hans J; Petzold, Christiane; Wohlfahrt, Johan C

    2015-09-01

    The aim of this study was to evaluate the effects of the remnants of two suture materials on osseointegration of titanium implants in a rabbit tibial model. Calibrated defects were prepared in the tibia of five Chinchilla rabbits. Filaments of nonresorbable (NR) nylon or resorbable (R) chitosan were placed at the bone to implant interface, whereas control sites had no suture material. After a healing period of 4 weeks, a pull-out test procedure was performed followed by enzymatic analyses of the wound fluid and relative quantification of mRNA levels for bone-related and cytokine markers from the peri-implant bone. A trend toward a reduced pull-out force was observed in the NR group (NR: 23.0 ± 12.8 N; R: 33.9 ± 11.3 N; control: 33.6 ± 24.0 N). Similarly, the bone resorption marker vacuolar type H+-ATPase was increased in the NR group compared with that in the control group (P = 0.041). The R group showed trends for lower alkaline phosphatase activity and osteocalcin expression and higher total protein content and RNA compared with the control group. In this submerged healing model, peri-implant bone healing was marginally affected by the two suture materials tested. However, there was a tendency toward better osseointegration and lower expression of bone resorption markers in the R group compared with the control group. PMID:26369486

  12. Crystal structures and properties of nylon polymers from theory

    SciTech Connect

    Dasgupta, S.; Goddard, W.A. III; Hammond, W.B.

    1996-12-11

    A complete force field (MSXX) for simulation of all nylon polymers is derived from ab initio quantum calculations. Special emphasis is given to the accuracy of the hydrogen bond potential for the amide unit and the torsional potential between the peptide and alkane fragments. The MSXX force field was used to predict the structures, moduli, and detailed geometries of all nine nylons for which there are experimental crystal data plus one other. For nylon-(2n) with 2n = 6, the {alpha} crystal structure (with all-trans CH{sub 2} chains nearly coplanar with the hydrogen bonding plane) is more stable, while for 2n > 6, {gamma} (with the alkane plane twisted by 70{degree}) is more stable. This change results from the increased importance of methylene packing interactions over H bonds for larger 2n. We find the highest Young`s modulus for nylon-7. 51 refs., 6 figs., 7 tabs.

  13. Moisture dependence of positron annihilation spectra in nylon-6

    NASA Technical Reports Server (NTRS)

    Singh, J. J.; St. Clair, T. L.; Holt, W. H.; Mock, W., Jr.

    1984-01-01

    Positron annihilation time spectra have been measured in nylon-6 samples as a function of their moisture content. The measured average long life component lifetime values are: 1722 + or - 47 ps (dry), 1676 + or - 40 ps (14.6 percent saturation value), 1719 + or - 26 ps (29.3 percent saturation value), 1720 + or - 35 ps (50 percent of saturation value), 1857 + or - 35 ps (78.1 percent saturation value), and 1936 + or - 57 ps (saturated). It appears that nylon-6 has a special affinity for water at low concentration levels where H2O molecules enter between the (C = O - H-N) chemical bonds between nylon molecular chains. As the water concentration increases beyond a critical level, nylon-6 specimens start trapping H2O molecules in other bond sites or potential wells. The trapped water increases the free volume in the test specimens and reduces Ps atom formation as well as its subsequent decay rate.

  14. Cellulase immobilized on modified nylon for saccharification of cellulose

    SciTech Connect

    Jain, P.; Wilkins, E.S.

    1987-01-01

    The present study deals with the immobilization of cellulase on nylon and nylon incorporated with glass. The immobilized and free enzymes were compared in terms of their yields, using untreated sawdust (yellow pine wood) and carboxymethylcellulose (CMC) as substrates, at a standard pH and temperature. Also, the sawdust was pretreated with 1% alkaline hydrogen peroxide and the yield compared with the untreated sawdust hydrolysis to determine the importance of the substrate pretreatment.

  15. Three-dimensional Structure of Nylon Hydrolase and Mechanism of Nylon-6 Hydrolysis*

    PubMed Central

    Negoro, Seiji; Shibata, Naoki; Tanaka, Yusuke; Yasuhira, Kengo; Shibata, Hiroshi; Hashimoto, Haruka; Lee, Young-Ho; Oshima, Shohei; Santa, Ryuji; Oshima, Shohei; Mochiji, Kozo; Goto, Yuji; Ikegami, Takahisa; Nagai, Keisuke; Kato, Dai-ichiro; Takeo, Masahiro; Higuchi, Yoshiki

    2012-01-01

    We performed x-ray crystallographic analyses of the 6-aminohexanoate oligomer hydrolase (NylC) from Agromyces sp. at 2.0 Å-resolution. This enzyme is a member of the N-terminal nucleophile hydrolase superfamily that is responsible for the degradation of the nylon-6 industry byproduct. We observed four identical heterodimers (27 kDa + 9 kDa), which resulted from the autoprocessing of the precursor protein (36 kDa) and which constitute the doughnut-shaped quaternary structure. The catalytic residue of NylC was identified as the N-terminal Thr-267 of the 9-kDa subunit. Furthermore, each heterodimer is folded into a single domain, generating a stacked αββα core structure. Amino acid mutations at subunit interfaces of the tetramer were observed to drastically alter the thermostability of the protein. In particular, four mutations (D122G/H130Y/D36A/E263Q) of wild-type NylC from Arthrobacter sp. (plasmid pOAD2-encoding enzyme), with a heat denaturation temperature of Tm = 52 °C, enhanced the protein thermostability by 36 °C (Tm = 88 °C), whereas a single mutation (G111S or L137A) decreased the stability by ∼10 °C. We examined the enzymatic hydrolysis of nylon-6 by the thermostable NylC mutant. Argon cluster secondary ion mass spectrometry analyses of the reaction products revealed that the major peak of nylon-6 (m/z 10,000–25,000) shifted to a smaller range, producing a new peak corresponding to m/z 1500–3000 after the enzyme treatment at 60 °C. In addition, smaller fragments in the soluble fraction were successively hydrolyzed to dimers and monomers. Based on these data, we propose that NylC should be designated as nylon hydrolase (or nylonase). Three potential uses of NylC for industrial and environmental applications are also discussed. PMID:22187439

  16. Application of Carbon Nanotubes to Nylon Composite

    NASA Astrophysics Data System (ADS)

    Suzuki, Tomoko; Inoue, Sakae; Nojima, Kazuhiro; Tsuchimoto, Akiharu; Chen, Beibei; Kumar, Mukul; Ando, Yoshinori

    2011-01-01

    Carbon nanotubes (CNTs) have many interesting mechanical properties. Therefore, it is expected that an excellent characteristic can be demonstrated by small addition of CNTs in various composite materials. In this study, nylon-6 (N6) was used as the base material and CNTs were mixed to it as a reinforcing agent. Three kinds of CNT were used as filler. Single-wall nanotubes (SWNTs) produced by arc plasma jet (APJ) method, SWNTs produced by ferrum-hydrogen arc (FHA) method, and multiwalled nanotubes (MWNTs) produced by chemical vapor deposition (CVD). Mechanical properties of the composites were measured by tension test, bending test and impact test. In general, when tensile or bending strength goes high, the value of impact energy falls. However, in the case of APJ-SWNT mixing in N6, the impact energy also increases together with the tensile and bending strengths. This study, thus, suggests that APJ-SWNT possesses a characteristic due to which the composite material is strengthened without losing its toughness.

  17. Mapping the suturing of a continental biota.

    PubMed

    Swenson, Nathan G

    2010-12-01

    The present-day spatial distribution of interspecific contact zones and intraspecific phylogeographical breaks provides a window into the past ecological and evolutionary processes that underlie speciation and species ranges. The clustering of contact zones and/or phylogeographical breaks in space indicates the suturing of diverged biotas. The presence of such suture zones indicates that similar ecological and historical factors have influenced the past and present distributions of populations and their divergence. Thus, suture zones are ideal natural laboratories for studying divergence, secondary contact and speciation across many different taxa. The concept of suture zones was formalized decades ago by Remington (1968), but only a few detailed and quantitative investigations of suture zones exist (Swenson & Howard 2004, 2005; Whinnett et al. 2005; Moritz et al. 2009). This limited number of investigations is largely because of a lack of detailed geographical data and sophisticated analytical tools. In this issue of Molecular Ecology, Rissler & Smith (2010) have accomplished a detailed investigation into the suturing of amphibian lineages in the United States which uses both detailed geographical data and sophisticated analytical methods. The work greatly enhances our knowledge of suture zones by extending previous work that has focused less on amphibians and by explicitly considering the relationship between species richness and suture zones. PMID:21134009

  18. The double loop mattress suture

    PubMed Central

    Biddlestone, John; Samuel, Madan; Creagh, Terry; Ahmad, Tariq

    2014-01-01

    An interrupted stitch type with favorable tissue characteristics will reduce local wound complications. We describe a novel high-strength, low-tension repair for the interrupted closure of skin, cartilage, and muscle, the double loop mattress stitch, and compare it experimentally with other interrupted closure methods. The performance of the double loop mattress technique in porcine cartilage and skeletal muscle is compared with the simple, mattress, and loop mattress interrupted sutures in both a novel porcine loading chamber and mechanical model. Wound apposition is assessed by electron microscopy. The performance of the double loop mattress in vivo was confirmed using a series of 805 pediatric laparotomies/laparoscopies. The double loop mattress suture is 3.5 times stronger than the loop mattress in muscle and 1.6 times stronger in cartilage (p ≤ 0.001). Additionally, the double loop mattress reduces tissue tension by 66% compared with just 53% for the loop mattress (p ≤ 0.001). Wound gapping is equal, and wound eversion appears significantly improved (p ≤ 0.001) compared with the loop mattress in vitro. In vivo, the double loop mattress performs as well as the loop mattress and significantly better than the mattress stitch in assessments of wound eversion and dehiscence. There were no episodes of stitch extrusion in our series of patients. The mechanical advantage of its intrinsic pulley arrangement gives the double loop mattress its favorable properties. Wound dehiscence is reduced because this stitch type is stronger and exerts less tension on the tissue than the mattress stitch. We advocate the use of this novel stitch wherever a high-strength, low-tension repair is required. These properties will enhance wound repair, and its application will be useful to surgeons of all disciplines. PMID:24698436

  19. CXCL12/CXCR4 axis regulates neovascularization and lymphangiogenesis in sutured corneas in mice.

    PubMed

    Du, Ling-Ling; Liu, Ping

    2016-06-01

    The present study aimed to determine the plausible functional role of chemokine (C‑X‑C motif) ligand 12 (CXCL12/chemokine (C‑X‑C motif) receptor 4 (CXCR4) in inflammatory corneal hemangiogenesis and lymphangiogenesis in vivo. Corneal hemangiogenesis and lymphangiogenesis were induced by placing an 11‑0 nylon suture in an intrastromal position. The expression levels of the vascular endothelial growth factor (VEGF) family, CXCL12 and CXCR4 in the corneas were investigated in the corneas using reverse transcription‑quantitative polymerase chain reaction and immunohistochemistry. Corneal hemangiogenic and lymphangiogenic responses were assessed by immunofluorescence using specific antibodies against cluster of differentiation 31 and lymphatic vessel endothelial hyaluronan receptor‑1. Subconjunctival injection of AMD3100 to the sutured corneas was also performed. CXCL12/CXCR4 mRNA and protein expression levels increased markedly in suture‑induced corneal neovascularization (CNV) and decreased with AMD3100 treatment. Hemangiogenesis and lymphangiogenesis were captured in images using immunofluorescence and were shown to be markedly increased with suture placement and reduced with AMD3100 treatment. VEGF‑A/VEGFR‑1 and VEGF‑C/VEGFR‑3 mRNA expression levels were upregulated in the suture placement and control groups, whereas the expression levels of all the factors were downregulated in the AMD3100 treatment group. The results from the present study demonstrated that CXCL12/CXCR4 interactions regulate hemangiogenesis and lymphangiogenesis in suture‑induced CNV. AMD3100 may be a novel therapeutic target for the prevention of blindness. PMID:27121088

  20. Investigation of sulfonated aromatic compound (SAC) modification to nylon film. 2. Study of SAC sorption isotherm and atomic force microscopic characterization of nylon surfaces

    SciTech Connect

    Zhang, J.; Watson, B.A.; Keown, R.W.; Malone, C.P.; Barteau, M.A.

    1995-08-01

    Nylon 6 and nylon 66 films have been treated with aqueous sulfonated aromatic compound (SAC) solutions at concentrations ranging from 0.005 to 1.0 wt%. SAC uptakes at different treatment concentrations were measured and found to follow a BET isotherm. The surface morphologies of nylon film samples, including the original and SAC-treated films, have been characterized by atomic force microscopy (AFM). For untreated nylon 6 and nylon 66 films, AFM images show a randomly distributed fibrillar surface structure. Characteristic widths of fibrils in the nylon 66 and 6 films were 150-225 and 75-150 nm, respectively. For SAC-treated nylon films, the AFM images revealed that the surfaces of the films became covered with nodule-like features having a diameter range of 25-60 nm. AFM analysis provides evidence that SAC treatment deposited a surface coating on nylon films. AFM images of SAC-treated nylon films suggest a mechanism for stain resistance in which the SAC first forms a thin coating on the nylon via bondings between attractive groups in the SAC and nylon polymers. After treatment at increased SAC concentration, the surface is covered with nodule-like deposits which likely serve as a physical barrier to dye permeation. 20 refs., 8 figs.

  1. Generalized Ferroelectricity in the Mesomorphic Phase of Nylon Polymers

    NASA Astrophysics Data System (ADS)

    Zhang, Zhongbo; Zhu, Lei; Litt, Morton

    Novel ferroelectric polymers, featured by narrow electric displacement-electric (D-E) hysteresis loop, are attractive for electric energy storage applications due to their high dielectric constant and low loss property. Currently, only poly(vinylidene fluoride) (PVDF)-based copolymers (e-beamed) and terpolymers show novel ferroelectric behavior. It is desired to achieve novel ferroelectricity in other polymers such as nylons by carefully modifying the chemical and crystal structures. In this presentation, isomorphic crystals are successfully achieved by copolymerization of nylon 11 and nylon 12 with different compositions. In this way, both chemical and structural defects (i.e., dangling amide groups and kinked bonds) are introduced into the mesomorphic phase. As a consequence, hydrogen bonding interaction is successfully weakened and thus enhanced ferroelectricity with higher maximum polarization and better polarizability is obtained. In addition, for the purpose of further disturbing the mesomorphic phase and pinning effect, partially methylated nylon copolymers are synthesized. With the help of N-methylation of amide groups, the methylated nylon copolymers show relatively narrow hysteresis loops, suggesting the pinning effect from the N-methylated amide moieties.

  2. Lifting and wound closure with barbed sutures.

    PubMed

    Mulholland, R Stephen; Paul, Malcolm D

    2011-07-01

    The advent of barbed sutures has been a novel and useful adjunct for the aesthetic plastic surgeon in properly selected patients. The deployment of a barbed suture minimizes the risks of cheese wiring and stress relaxation, facilitating the minimally invasive repositioning of soft tissue in the head and neck, as well as optimizing and enhancing traditionally long and potentially tedious procedures in body contouring. This article highlights the advances, advantages, and efficacy associated with the use of barbed sutures in lifting and wound closure. PMID:21824547

  3. Suture slippage in knotless suture anchors resulting in subacromial-subdeltoid bursitis.

    PubMed

    Hayeri, Mohammad Reza; Keefe, Daniel T; Chang, Eric Y

    2016-05-01

    Rotator cuff repair using a suture bridge and knotless suture anchors is a relatively new, but increasingly used technique. The suture bridge technique creates an anatomically similar and more secure rotator cuff repair compared with conventional arthroscopic techniques and the use of knotless anchors eliminates the challenges associated with knot tying during arthroscopic surgery. However, previous in vitro biomechanical tests have shown that the hold of the suture in a knotless suture anchor is far lower than the pullout strength of the anchor from bone. Up until now slippage has been a theoretical concern. We present a prospectively diagnosed case of in vivo suture loosening after rotator cuff repair using a knotless bridge technique resulting in subacromial-subdeltoid bursitis. PMID:26739301

  4. Testing of SRS and RFETS Nylon Bag Material

    SciTech Connect

    Laurinat, J.E.

    1998-11-03

    This report compares the effects of radiation and heating on nylon bagout materials used at the Savannah River Site (SRS) and the Rocky Flats Environmental Technology Site (RFETS). Recently, to simplify the processing of sand, slag, and crucible (SS and C), FB-Line has replaced the low-density polyethylene (LDPE) and polyvinyl chloride (PVC) bags normally used to package cans of plutonium-bearing material with nylon bags. LDPE and PVC are not soluble in the nitric acid dissolver solution used in F-Canyon, so cans bagged using these materials had to be repackaged before they were added to the dissolver. Because nylon dissolves in nitric acid, cans bagged in nylon can be charged to the F-Canyon dissolvers without repackaging, thereby reducing handling requirements and personnel exposure. As part of a program to process RFETS SS and C at SRS, RFETS has also begun to use a nylon bagout material. The RFETS bag materials is made from a copolymer of nylon 6 and nylon 6.9, while the SRS material is made from a nylon 6 monomer. In addition, the SRS nylon has an anti-static agent added. The RFETS nylon is slightly softer than the SRS nylon, but does not appear to be as resistant to flex cracks initiated by contact with sharp corners of the inner can containing the SS and C.2 FB-Line Operations has asked for measurement of the effects of radiation and heating on these materials. Specifically, they have requested a comparison of the material properties of the plastics before and after irradiation, a measurement of the amount of outgassing when the plastics are heated, and a calculation of the amount of radiolytic gas generation. Testing was performed on samples taken from material that is currently used in FB-Line (color coded orange) and at RFETS. The requested tests are the same tests previously performed on the original and replacement nylon and LDPE bag materials.3,4,5. To evaluate the effect of irradiation on material properties, tensile stresses and elongations to break

  5. Treatment of Suture-related Complications of Buried-suture Double-eyelid Blepharoplasty in Asians

    PubMed Central

    2016-01-01

    Background: Double-eyelid blepharoplasty is a popular aesthetic surgery in Asians. However, the buried suture technique is associated with complications related to implantation of the suture thread. The present study was performed to identify optimal surgical suture removal techniques in Japanese patients with suture-related complications after buried suture double-eyelid blepharoplasty. Methods: This retrospective study included 210 upper eyelids of 116 consecutive Japanese patients who had undergone buried suture double-eyelid blepharoplasty at other clinics. All patients underwent suture removal surgery at the author's institution for treatment of suture-related complications. Although 12 patients (10.3%) underwent suture removal surgery alone, 104 (89.7%) underwent secondary double-eyelid blepharoplasty. The outcomes of 3 techniques were evaluated: the small skin incision method, the full skin incision method, and the conjunctival method. Results: The small skin incision method was performed in 46 patients, the full skin incision method in 63, and the conjunctival method in 7. The success rate of the full skin incision method was significantly higher than that of the small skin incision method (4.8% vs 37.0%, respectively; p < 0.0001). Patients with an uncomfortable pulling sensation exhibited a linear scar or depressive deformity without inflammation of the tarsal plate and impingement on the subconjunctival capillary vessels of the tarsal plate or a depressive deformity of the levator muscle. Patients with corneal irritation exhibited chronic inflammation of the conjunctival surface of the tarsal plate. Conclusions: Suture-related complications of buried suture double-eyelid blepharoplasty in Asians must be treated with suture removal surgery. The full skin incision method is more reliable than the small incision method for such patients. PMID:27622107

  6. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stainless steel suture. 878.4495 Section 878.4495...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a) Identification. A stainless steel suture is a needled or unneedled nonabsorbable surgical suture composed of...

  7. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Stainless steel suture. 878.4495 Section 878.4495...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a) Identification. A stainless steel suture is a needled or unneedled nonabsorbable surgical suture composed of...

  8. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Stainless steel suture. 878.4495 Section 878.4495...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a) Identification. A stainless steel suture is a needled or unneedled nonabsorbable surgical suture composed of...

  9. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Stainless steel suture. 878.4495 Section 878.4495...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a) Identification. A stainless steel suture is a needled or unneedled nonabsorbable surgical suture composed of...

  10. 21 CFR 878.4495 - Stainless steel suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Stainless steel suture. 878.4495 Section 878.4495...) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4495 Stainless steel suture. (a) Identification. A stainless steel suture is a needled or unneedled nonabsorbable surgical suture composed of...

  11. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Natural nonabsorbable silk surgical suture. 878... Natural nonabsorbable silk surgical suture. (a) Identification. Natural nonabsorbable silk surgical suture... Bombycidae. Natural nonabsorbable silk surgical suture is indicated for use in soft tissue...

  12. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Natural nonabsorbable silk surgical suture. 878... Natural nonabsorbable silk surgical suture. (a) Identification. Natural nonabsorbable silk surgical suture... Bombycidae. Natural nonabsorbable silk surgical suture is indicated for use in soft tissue...

  13. Laceration - sutures or staples - at home

    MedlinePlus

    ... this page: //medlineplus.gov/ency/patientinstructions/000498.htm Laceration - sutures or staples - at home To use the ... features on this page, please enable JavaScript. A laceration is a cut that goes all the way ...

  14. Subscapularis Tendon Repair Using Suture Bridge Technique

    PubMed Central

    Park, Yong Bok; Park, Young Eun; Koh, Kyoung Hwan; Lim, Tae Kang; Shon, Min Soo; Yoo, Jae Chul

    2015-01-01

    The subscapularis tendon plays an essential role in shoulder function. Although subscapularis tendon tears are less common than other rotator cuff tears, tears of the subscapularis tendon have increasingly been recognized with the advent of magnetic resonance imaging and arthroscopy. A suture bridge technique for the treatment of posterosuperior rotator cuff tears has provided the opportunity to improve the pressurized contact area and mean footprint pressure. However, suture bridge fixation of subscapularis tendon tears appears to be technically challenging. We describe an arthroscopic surgical technique for suture bridge repair of subscapularis tendon tears that obtains ideal cuff integrity and footprint restoration. Surgery using such a suture bridge technique is indicated for large tears, such as tears involving the entire first facet or more, tears with a disrupted lateral sling, and combined medium to large supraspinatus/infraspinatus tears. PMID:26052489

  15. Usefulness of braided polyblend polyethylene suture material for flexor tendon repair in zone II by the side-locking loop technique.

    PubMed

    Ryoke, Koji; Uchio, Yuji; Yamagami, Nobuo; Kuwata, Suguru; Nozaki, Kenji; Yamamoto, Soichiro; Tsujimoto, Yumiko

    2014-01-01

    Flexor tendon injuries in zone II were treated in 14 fingers of 13 patients with our method. Firstly, a 2-strand core suture was made by the side-locking loop technique using a USP 2-0-sized braided polyblend polyethylene suture, then 7-strand peripheral cross-stitches were added using a USP 5-0-sized monofilament nylon suture. Post-operative exercises included passive flexion and extension without external fixation on the next day of surgery. Average follow-up observation period was 18 months. As results, the Strickland method of assessment for surgical outcome showed excellent in eight digits and good in five digits, though there was a poor outcome in one digit. Our suture method enabled early post-operative mobilisation exercise without using a splint, while preventing adhesion between the repaired tendon and peripheral tissues, which is considered to provide far greater ultimate tensile strength and a smaller gap at the sutured site than by the conventional method. PMID:24875521

  16. Electrospun nylon 6 microfiltration membrane for treatment of brewery wastewater

    NASA Astrophysics Data System (ADS)

    Islam, Md. Shahidul; Sultana, Sormin; Rahaman, Md. Saifur

    2016-07-01

    Nylon 6 microfiltration membrane, for the treatment of brewery wastewater, was fabricated using an electrospinning technique, followed by hot-pressing. The fabricated membrane was robust and demonstrated highly hydrophilic property (water contact angle 39° at the touching point to the membrane surface and the water droplet was completely immersed into the membrane in 7 seconds), and higher porosity (65%) with pore sizes of 100 to 210 nm. The electrospun nylon 6 membrane showed higher pure water flux (850 LMH) at an applied pressure of 4 psi. The same membrane also demonstrated a 95% rejection rate of suspended solids (SS) in brewery wastewater treatment.

  17. Nylon Sleeve for Cavity Amplifier Holds Tuning Despite Heat

    NASA Technical Reports Server (NTRS)

    Derr, Lloyd

    1964-01-01

    The problem: Detuning of cavity amplifiers with change in temperature. This results in deterioration of the performance of the amplifier at its design frequency. In cavity amplifiers and filters it is desirable that constant performance be maintained regardless of thermal changes. These changes often cause an "off resonance shift" in a cavity filter and a deterioration of performance in a cavity amplifier. The solution: Mount the tuning probe in a nylon sleeve. Thermal expansion and contraction of the nylon nullifies unwanted capacitive and inductive changes in the resonant elements.

  18. Frimand Needle Holder Reduces Suturing Time and Surgical Stress When Suturing in Palm Grip.

    PubMed

    Frimand Rönnow, Carl-Fredrik; Jeppsson, Bengt; Thorlacius, Henrik

    2016-06-01

    Purpose The Frimand needle holder (FNH) was developed to facilitate palm grip suturing. In the present study, we wanted to examine the impact of the FNH compared with a conventional Hegar-styled needle holder (HSNH) on suture time and surgical stress. Methods Thirty-two surgeons were enrolled and they performed sets of 3 continuous sutures on a polyurethane pad with premarked insert and exit points and the time for suturing was measured. Surgical stress was quantified by having the surgeons to perform 10 release maneuvers with the FNH and the HSNH on a needle attached to a scale. The scale sent 5 values per second to a computer. The first measurement of each series was regarded as the starting weight and all subsequent measurements were either regarded as neutral, pressure or traction. The sum of these measurements represented total surgical stress. Results We found that all surgeons reduced their median suturing time by 16% when using FNH for palm grip suturing with no difference between junior and senior surgeons. Moreover, it was observed that FNH decreased median surgical stress by 62% for all surgeons performing palm grip suturing compared with a conventional HSNH. Conclusion We conclude that the FNH reduces suture time and surgical stress compared with HSNH when performing palm grip suturing. These findings warrant studies in surgical patients in order to evaluate the potential clinical impact of FNH. PMID:26474606

  19. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 3 2012-04-01 2012-04-01 false Vinylidene chloride copolymer coatings for nylon... coatings for nylon film. Vinylidene chloride copolymer coatings identified in this section and applied on nylon film may be safely used as food-contact surfaces, in accordance with the following...

  20. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 3 2010-04-01 2009-04-01 true Vinylidene chloride copolymer coatings for nylon... coatings for nylon film. Vinylidene chloride copolymer coatings identified in this section and applied on nylon film may be safely used as food-contact surfaces, in accordance with the following...

  1. Electrospun fiber and cast films produced using zein blends with nylon-6

    Technology Transfer Automated Retrieval System (TEKTRAN)

    Blends of zein and nylon-6 (55k) were used to produce electrospun fibers and solution cast films. Zein was blended with nylon-6 in formic acid solution. When the amount of nylon-6 was 8% or less a compatible blend formed. The blend was determined to be compatible based on physical property measureme...

  2. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 3 2014-04-01 2014-04-01 false Vinylidene chloride copolymer coatings for nylon... Use as Components of Coatings § 175.360 Vinylidene chloride copolymer coatings for nylon film. Vinylidene chloride copolymer coatings identified in this section and applied on nylon film may be...

  3. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 3 2011-04-01 2011-04-01 false Vinylidene chloride copolymer coatings for nylon... coatings for nylon film. Vinylidene chloride copolymer coatings identified in this section and applied on nylon film may be safely used as food-contact surfaces, in accordance with the following...

  4. 21 CFR 175.360 - Vinylidene chloride copolymer coatings for nylon film.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 3 2013-04-01 2013-04-01 false Vinylidene chloride copolymer coatings for nylon... coatings for nylon film. Vinylidene chloride copolymer coatings identified in this section and applied on nylon film may be safely used as food-contact surfaces, in accordance with the following...

  5. Shear lag sutures: Improved suture repair through the use of adhesives.

    PubMed

    Linderman, Stephen W; Kormpakis, Ioannis; Gelberman, Richard H; Birman, Victor; Wegst, Ulrike G K; Genin, Guy M; Thomopoulos, Stavros

    2015-09-01

    Suture materials and surgical knot tying techniques have improved dramatically since their first use over five millennia ago. However, the approach remains limited by the ability of the suture to transfer load to tissue at suture anchor points. Here, we predict that adhesive-coated sutures can improve mechanical load transfer beyond the range of performance of existing suture methods, thereby strengthening repairs and decreasing the risk of failure. The mechanical properties of suitable adhesives were identified using a shear lag model. Examination of the design space for an optimal adhesive demonstrated requirements for strong adhesion and low stiffness to maximize the strength of the adhesive-coated suture repair construct. To experimentally assess the model, we evaluated single strands of sutures coated with highly flexible cyanoacrylates (Loctite 4903 and 4902), cyanoacrylate (Loctite QuickTite Instant Adhesive Gel), rubber cement, rubber/gasket adhesive (1300 Scotch-Weld Neoprene High Performance Rubber & Gasket Adhesive), an albumin-glutaraldehyde adhesive (BioGlue), or poly(dopamine). As a clinically relevant proof-of-concept, cyanoacrylate-coated sutures were then used to perform a clinically relevant flexor digitorum tendon repair in cadaver tissue. The repair performed with adhesive-coated suture had significantly higher strength compared to the standard repair without adhesive. Notably, cyanoacrylate provides strong adhesion with high stiffness and brittle behavior, and is therefore not an ideal adhesive for enhancing suture repair. Nevertheless, the improvement in repair properties in a clinically relevant setting, even using a non-ideal adhesive, demonstrates the potential for the proposed approach to improve outcomes for treatments requiring suture fixation. Further study is necessary to develop a strongly adherent, compliant adhesive within the optimal design space described by the model. PMID:26022966

  6. Functional implications of squamosal suture size in paranthropus boisei.

    PubMed

    Dzialo, Christine; Wood, Sarah A; Berthaume, Michael; Smith, Amanda; Dumont, Elizabeth R; Benazzi, Stefano; Weber, Gerhard W; Strait, David S; Grosse, Ian R

    2014-02-01

    It has been hypothesized that the extensively overlapping temporal and parietal bones of the squamosal sutures in Paranthropus boisei are adaptations for withstanding loads associated with feeding. Finite element analysis (FEA) was used to investigate the biomechanical effects of suture size (i.e., the area of overlap between the temporal and parietal bones) on stress, strain energy, and strain ratio in the squamosal sutures of Pan troglodytes and P. boisei (specimen OH 5) during biting. Finite element models (FEMs) of OH 5 and a P. troglodytes cranium were constructed from CT scans. These models contain sutures that approximate the actual suture sizes preserved in both crania. The FEM of Pan was then modified to create two additional FEMs with squamosal sutures that are 50% smaller and 25% larger than those in the original model. Comparisons among the models test the effect of suture size on the structural integrity of the squamosal suture as the temporal squama and parietal bone move relative to each other during simulated premolar biting. Results indicate that with increasing suture size there is a decreased risk of suture failure, and that maximum stress values in the OH 5 suture were favorable compared to values in the Pan model with the normal suture size. Strain ratios suggest that shear is an important strain regime in the squamosal suture. This study is consistent with the hypothesis that larger sutures help reduce the likelihood of suture failure under high biting loads. PMID:24242913

  7. Comparative adherence of granulocytes to endothelial monolayers and nylon fiber.

    PubMed

    MacGregor, R R; Macarak, E J; Kefalides, N A

    1978-03-01

    Adherence of granulocytes to tissue culture monolayers of endothelium averaged 26.2 +/- 1.3% SEM, which was similar to their adherence on 50-mg nylon fiber columns (27.7 +/- 3.6%). In contrast, adherence to epithelial cells, fibroblasts, kidney cells, and plastic Petri dishes without monolayers was only 12.4, 9.9, 11.1, and 4.3%, respectively. Cyclic nucleotides and adherence-modifying plasma factors induced changes of adherence to endothelium similar to those in nylon fiber columns. Adherence of granulocytes in whole blood was the same as for purified granulocytes in Hank's balanced salt solution. Exposure of endothelial monolayers to 0.18% trypsin for 10 min reduced subsequent granulocyte adherence to 25.2% of control values. Incubation of trypsin-treated monolayers with nutrient medium for 4 h did not improve adherence, but values returned to normal or above by 24 h, with or without serum proteins present in the nutrient medium. The similarity of granulocyte adherence to nylon fiber and to endothelial monolayers in vitro suggests that results with the nylon fiber assay reflect in vivo granulocyte-endothelium interaction. Furthermore, the endothelial monolayer offers a new model for studying this cell-cell relationship in vitro. PMID:641148

  8. Carpet Specifiers Guide. Ultron, Advanced Generation Nylon Carpet Fiber.

    ERIC Educational Resources Information Center

    Monsanto Textiles Co., Atlanta, GA.

    The purpose of this guide is to assist specifiers in properly specifying carpet made of Monsanto Ultron advanced generation nylon fiber. The guide describes a variety of conditions that should be considered in arriving at the proper selection and provides reference information and data, ranging from varying regulatory requirements, performance and…

  9. Nylon shock absorber prevents injury to parachute jumpers

    NASA Technical Reports Server (NTRS)

    Mandel, J. A.

    1966-01-01

    Nylon shock absorbers reduce the canopy-opening shock of a parachute to a level that protects the wearer from injury. A shock absorber is mounted on each of the four risers between the shroud lines and the harness. Because of their size and location, they pose no problem in repacking the chute and harness after a jump.

  10. A New Suturing Device for Small Arteries.

    PubMed

    Kondo, Ryoichi; Itoda, Yoshifumi; Panthee, Nirmal; Inui, Akitoshi; Ashiba, Hiroshi; Ando, Takehiro; Kobayashi, Etsuko; Sakuma, Ichiro; Ono, Minoru

    2016-05-25

    Endoscope-assisted surgery and robot-assisted surgery are not common in cardiac surgery, particularly coronary artery bypass grafting, because of the complex nature of the procedures. We developed a new suturing device that allows for easy performance of such cardiac surgeries in comparison with conventional suturing methods. A total of 63 rabbits were used in this study. The right carotid artery was bypassed using the same side of the jugular vein under endoscopic guidance. Of these, 48 rabbits were operated on using the new devices and 15 rabbits were operated on using conventional polypropylene sutures. The proximal suturing time was 16.6 ± 5.3 minutes in the group that underwent surgery using the new device (group D) and 22.8 ± 7.6 minutes in the control group (group C; P < 0.05). The distal suture time was 16.3 ± 4.2 minutes in group D and 22.8 ± 6.0 minutes in group C (P < 0.05). The operation time was 113.0 ± 15.8 minutes in group D and 136.7 ± 20.6 minutes in group C (P < 0.05). Graft flow was 19.9 ± 12.8 mL/minute in group D and 12.1 ± 11.3 mL/minute in group C (P < 0.05). Thus, the operation time and the suture time differed significantly between the groups. This device provides advantages in endoscopic surgery compared to the conventional suture method. PMID:27181185

  11. Pediatric Coronal Suture Fiber Alignment and the Effect of Interdigitation on Coronal Suture Mechanical Properties.

    PubMed

    Adamski, Kelly Nicole; Loyd, Andre Matthew; Samost, Albert; Myers, Barry; Nightingale, Roger; Smith, Kathleen; 'Dale' Bass, Cameron R

    2015-09-01

    The morphological and mechanical properties of the pediatric skull are important in understanding pediatric head injury biomechanics. Although previous studies have analyzed the morphology of cranial sutures, none has done so in pediatric specimens nor have previous studies related the morphology to mechanical properties of human sutures. This study quantified the geometry of pediatric cranial sutures and investigated its correlation with the suture mechanical properties. First, the suture fiber alignment was quantified using histological analysis for four ages-neonate, 9 months-old, 11 months-old, and 18 months-old. For the morphometric investigation of the suture interdigitation, suture samples from a 6-year-old were scanned using micro-CT and the level of interdigitation was measured using two techniques. The first technique, the sinuosity index, was calculated by dividing the suture path along the surface of the skull by the suture distance from beginning to end. The second technique, the surface area interdigitation index, was calculated by measuring the surface area of the bone interface outlining the suture and dividing it by the cross-sectional area of the bone. The mechanical properties were obtained using methods reported in Davis et al.6. The results of the histological analysis showed a significant increase in fiber alignment in older specimen; where random fiber alignment has an average angle deviation of 45°, neonatal suture fibers have an average deviation of 32.2° and the 18-month-old fibers had an average deviation of 16.2° (p < 0.0001). For the suture index measurements, only the sinuosity was positively correlated with the ultimate strain (R (2) = 0.62, Bonferroni corrected p = 0.011) but no other measurements showed a significant relationship, including the amount of interdigitation and elastic modulus. Our results demonstrate that there is a distinct developmental progression of the suture fiber alignment at a young age, but the

  12. The history and evolution of sutures in pelvic surgery

    PubMed Central

    Muffly, Tyler M; Tizzano, Anthony P; Walters, Mark D

    2011-01-01

    Summary The purpose of the study is to review the history and innovations of sutures used in pelvic surgery. Based on a review of the literature using electronic- and hand-searched databases we identified appropriate articles and gynaecology surgical textbooks regarding suture for wound closure. The first documented uses of suture are explored and then the article focuses on the use of knotted materials in pelvic surgery. The development of suture of natural materials is followed chronologically until the present time where synthetic suture is implanted during countless surgeries every day. This millennial history of suture contains an appreciation of the early work of Susruta, Celsus, Paré and Lister, including a survey of some significant developments of suture methods over the last 100 years. Most surgeons know little about the history and science of sutures. A retrospective view of suture is critical to the appreciation of the current work and development of this common tool. PMID:21357979

  13. Fourier technique for studying ammonoid sutures

    SciTech Connect

    Gildner, R.F.; Ackerly, S.C.

    1985-01-01

    Suture patterns have long been recognized as being of primary importance in the study of ammonoids. The authors have developed a technique to use Fourier analysis to study these structures by using a simple transformation: x-y data of a digitized suture are transformed to angle of slope versus position along the suture's length. A Fast Fourier Transform applied to the data produces a power spectrum (amplitude versus wave number) providing a precise and accurate measure of suture shape. The authors have applied this technique to the analysis of ontogenetic change in suture morphology. In goniatitic, ceratitic and preadult ammonitic patterns most of the change is exhibited in the amplitudes of the lowest ten wave numbers. Their Fourier coefficients clearly show trends not readily apparent by visual inspection. The more complex ammonitic patterns are reflected in increased amplitudes of higher wave numbers (a broader peak of the power spectrum) and their analysis is necessarily more complex. The Fourier approach presents the opportunity to quantitatively measure and describe the tempo and mode of evolution in the Ammonoidea. Potential applications of the new technique, as well as limitations, are discussed with special attention to investigations of ammonoid ontogeny and phylogeny.

  14. The cell biology of suturing tendons

    PubMed Central

    Wong, J.K.F.; Alyouha, S.; Kadler, K.E.; Ferguson, M.W.J.; McGrouther, D.A.

    2010-01-01

    Trauma by suturing tendon form areas devoid of cells termed “acellular zones” in the matrix. This study aimed to characterise the cellular insult of suturing and acellular zone formation in mouse tendon. Acellular zone formation was evaluated using single grasping sutures placed using flexor tendons with time lapse cell viability imaging for a period of 12 h. Both tension and injury were required to induce cell death and cell movement in the formation of the acellular zone. DNA fragmentation studies and transmission electron microscopy indicated that cells necrosed. Parallel in vivo studies showed that cell-to-cell contacts were disrupted following grasping by the suture in tensioned tendon. Without tension, cell death was lessened and cell-to-cell contacts remained intact. Quantitative immunohistochemistry and 3D cellular profile mapping of wound healing markers over a one year time course showed that acellular zones arise rapidly and showed no evidence of healing whilst the wound healing response occurred in the surrounding tissues. The acellular zones were also evident in a standard modified “Kessler” clinical repair. In conclusion, the suture repair of injured tendons produces acellular zones, which may potentially cause early tendon failure. PMID:20600895

  15. The cell biology of suturing tendons.

    PubMed

    Wong, J K F; Alyouha, S; Kadler, K E; Ferguson, M W J; McGrouther, D A

    2010-07-01

    Trauma by suturing tendon form areas devoid of cells termed "acellular zones" in the matrix. This study aimed to characterise the cellular insult of suturing and acellular zone formation in mouse tendon. Acellular zone formation was evaluated using single grasping sutures placed using flexor tendons with time lapse cell viability imaging for a period of 12h. Both tension and injury were required to induce cell death and cell movement in the formation of the acellular zone. DNA fragmentation studies and transmission electron microscopy indicated that cells necrosed. Parallel in vivo studies showed that cell-to-cell contacts were disrupted following grasping by the suture in tensioned tendon. Without tension, cell death was lessened and cell-to-cell contacts remained intact. Quantitative immunohistochemistry and 3D cellular profile mapping of wound healing markers over a one year time course showed that acellular zones arise rapidly and showed no evidence of healing whilst the wound healing response occurred in the surrounding tissues. The acellular zones were also evident in a standard modified "Kessler" clinical repair. In conclusion, the suture repair of injured tendons produces acellular zones, which may potentially cause early tendon failure. PMID:20600895

  16. Pulmonary suture abscess with false-positive 18F-fluorodeoxyglucose positron emission scan mimicking lung cancer recurrence.

    PubMed

    Iwasaki, Teruo; Nakagawa, Katsuhiro; Katsura, Hiroshi; Nakane, Shigeru; Kawahara, Kunimitsu; Fukuda, Haruyuki

    2006-08-01

    We present the case of a 57-year-old woman with pulmonary suture abscess. She had undergone right S3 segmentectomy for early lung adenocarcinoma 7 years before and right breast-conserving surgery for invasive ductal carcinoma 5 months previously, followed by irradiation plus endocrine therapy. Chest radiography and computed tomography revealed an irregular mass (3.5 cm in diameter) between the residual S1 segment and the middle lobe, neighboring the staple line of the segmentectomy. 18F-fluorodeoxyglucose uptake into the mass increased, seen by positron emission scans. Therefore, we could not rule out the possibility of local recurrence of lung cancer and resected it. Pathologically and microbiologically, the mass was a suture abscess arising around the nylon suture of the previous segmentectomy. This lesion was the result of a foreign-body reaction, as confirmed by polarized microscopy. Moreover, titanium staples at the segmentectomy and breast-conserving surgery may also have contributed to this condition. PMID:16972643

  17. Pentachlorophenol sorption in nylon fiber and removal by immobilized Rhizopus oryzae ENHE.

    PubMed

    León-Santiestebán, Hugo; Meraz, Mónica; Wrobel, Kazimierz; Tomasini, Araceli

    2011-06-15

    This study describes pentachlophenol (PCP) sorption in nylon fiber in which Rhizopus oryzae ENHE was immobilized to remove the chemical compound. The experimental sorption data were analyzed using the Langmuir, Freundlich, and Redlich-Peterson isotherm models using non-linear error functions to fit the experimental data to the three models. Results showed that the isotherm obtained from the data fitted the three models used. However, the g parameter from Redlich-Peterson model showed that the isotherm obtained approaches the Freundlich model. This support reached the sorption equilibrium concentration at 3mg PCPg(-1)nylon. To study PCP removal capability by R. oryzae ENHE and to eliminate the error caused by PCP sorbed by the nylon fiber during its quantification, nylon fiber at PCP equilibrium sorption concentration was used to immobilize R. oryzae ENHE. It was found that this fungus grew within nylon fiber cubes in presence or not of PCP, even when PCP caused growth inhibition. Maximum biomass accumulated into nylon cubes without PCP was of 32 mg biomass g(-1)nylon and into nylon cubes at PCP equilibrium concentration was of 18 mg g(-1)nylon. The results showed that R. oryzae ENHE immobilized into nylon fiber removed 88.6% and 92% of PCP in cultures with 12.5 and 25 mg PCPL(-1), as initial concentration, respectively. This is the first work to report that a zygomycete, such as R. oryzae ENHE, immobilized into nylon fiber kept its potential to remove PCP. PMID:21514996

  18. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 1 2012-04-01 2012-04-01 false What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT OF...' COMPENSATION ACT, AS AMENDED General Provisions Introduction § 10.0 What are the provisions of the FECA,...

  19. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 1 2014-04-01 2012-04-01 true What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT OF...' COMPENSATION ACT, AS AMENDED General Provisions Introduction § 10.0 What are the provisions of the FECA,...

  20. Endoscopic navigation for minimally invasive suturing.

    PubMed

    Wengert, Christian; Bossard, Lukas; Häberling, Armin; Baur, Charles; Székely, Gábor; Cattin, Philippe C

    2007-01-01

    Manipulating small objects such as needles, screws or plates inside the human body during minimally invasive surgery can be very difficult for less experienced surgeons, due to the loss of 3D depth perception. This paper presents an approach for tracking a suturing needle using a standard endoscope. The resulting pose information of the needle is then used to generate artificial 3D cues on the 2D screen to optimally support surgeons during tissue suturing. Additionally, if an external tracking device is provided to report the endoscope's position, the suturing needle can be tracked in a hybrid fashion with sub-millimeter accuracy. Finally, a visual navigation aid can be incorporated, if a 3D surface is intraoperatively reconstructed from video or registered from preoperative imaging. PMID:18044620

  1. The past and present of liver suture.

    PubMed

    Komorowski, Andrzej L; Lukashenko, Andriy; Chang, Yu-Chung

    2014-02-01

    Since the first attempts at resecting parts of diseased livers in the late nineteenth century, hemorrhage has been the main obstacle for surgeons. One of the first hemostasis techniques in liver resection was liver suture. The idea of suturing the liver in order to perform resection was proposed by a team of Russian and Polish surgeons from Kharkiv University in today's Ukraine. The liver suture became widely popular and has been used in various forms throughout the surgical world. Further into the twentieth century, it has lost much of its popularity; however, over more than 100 years of existence it has seen several peaks in interest. Currently, it is still being used by some liver surgeons as it is one of the cheapest ways of obtaining a bloodless liver parenchyma transection. PMID:24132823

  2. Nanostructured medical sutures with antibacterial properties.

    PubMed

    Serrano, Cristina; García-Fernández, Luis; Fernández-Blázquez, Juan Pedro; Barbeck, Mike; Ghanaati, Shahram; Unger, Ron; Kirkpatrick, James; Arzt, Eduard; Funk, Lutz; Turón, Pau; del Campo, Aránzazu

    2015-06-01

    Bacterial repellence in suture materials is a desirable property that can potentially improve the healing process by preventing infection. We describe a method for generating nanostructures at the surface of commercial sutures of different composition, and their potential for preventing biofilm formation. We show how bacteria attachment is altered in the presence of nanosized topographies and identify optimum designs for preventing it without compromising biocompatibility and applicability in terms of nanostructure robustness or tissue friction. These studies open new possibilities for flexible and cost-effective realization of topography-based antibacterial coatings for absorbable biomedical textiles. PMID:25818435

  3. Isolating Suture Slippage During Cadaveric Testing of Knotless Anchors.

    PubMed

    Klinge, Stephen A; Vopat, Bryan G; Paller, David; Avery, Anthony L; Koruprolu, Sarath; Fadale, Paul D

    2015-07-01

    We evaluated a testing method designed to isolate and analyze the effectiveness of different suture-retention mechanisms in knotless suture anchors used for rotator cuff repairs. Six knotless PushLock implants (Arthrex) with a suture-retention mechanism dependent on a press-fit of suture between the anchor's outer diameter and surrounding bone were compared with 6 ReelX STT devices (Stryker) reliant on an intrinsic suture-locking mechanism. Suture slippage beyond minimal clinical failure thresholds, as well as ultimate failure load, were determined with a novel testing fixture that isolated suture slippage. Suture slippage was isolated from anchor-bone disengagement. Each PushLock exhibited suture slippage of more than 3 mm, and each ReelX exhibited slippage of less than 3 mm. The PushLock implants also exhibited significantly (P < .05) more interval and maximum slippage; 5 of these 6 implants failed via complete suture slippage before dynamic testing could be completed. All ReelX devices survived dynamic testing and ultimately failed via suture breakage. This novel axial load biomechanical testing technique isolated suture slippage in 2 uniquely designed knotless anchors. The press-fit PushLock implant was prone to slippage failure, whereas the ReelX device with its internal suture-locking mechanism exhibited minimal slippage. PMID:26161766

  4. Optimal Suturing Technique and Number of Sutures for Surgical Implantation of Acoustic Transmitters in Juvenile Salmonids

    SciTech Connect

    Deters, Katherine A.; Brown, Richard S.; Boyd, James W.; Eppard, M. B.; Seaburg, Adam

    2012-01-02

    The size reduction of acoustic transmitters has led to a reduction in the length of incision needed to implant a transmitter. Smaller suture knot profiles and fewer sutures may be adequate for closing an incision used to surgically implant an acoustic microtransmitter. As a result, faster surgery times and reduced tissue trauma could lead to increased survival and decreased infection for implanted fish. The objective of this study was to assess the effects of five suturing techniques on mortality, tag and suture retention, incision openness, ulceration, and redness in juvenile Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Suturing was performed by three surgeons, and study fish were held at two water temperatures (12°C and 17°C). Mortality was low and tag retention was high for all treatments on all examination days (7, 14, 21, and 28 days post-surgery). Because there was surgeon variation in suture retention among treatments, further analyses included only the one surgeon who received feedback training in all suturing techniques. Incision openness and tissue redness did not differ among treatments. The only difference observed among treatments was in tissue ulceration. Incisions closed with a horizontal mattress pattern had more ulceration than other treatments among fish held for 28 days at 17°C. Results from this study suggest that one simple interrupted 1 × 1 × 1 × 1 suture is adequate for closing incisions on fish under most circumstances. However, in dynamic environments, two simple interrupted 1 × 1 × 1 × 1 sutures should provide adequate incision closure. Reducing bias in survival and behavior tagging studies is important when making comparisons to the migrating salmon population. Therefore, by minimizing the effects of tagging on juvenile salmon (reduced tissue trauma and reduced surgery time), researchers can more accurately estimate survival and behavior.

  5. Suture needles in Oral Surgery: Alterations depending on the type and number of sutures

    PubMed Central

    Barranco-Piedra, Sebastian; Rodríguez-Caballero, Angela; Serrera-Figallo, María-Angeles; Segura-Egea, Juan-José; Gutiérrez-Pérez, José-Luis

    2012-01-01

    This study examined whether the number and type of sutures used in oral surgery influence two ad hoc variables (incision plane and displaced area), which are two variables related to whether the suture needle is suitable for the task. Seventy-five TB-15 needles were studied, which were used to suture between zero and three mucosa and/subperiosteal sutures, producing 15 groups with 5 needles in each one. The incision plane and displaced area were measured for each group, which are two variables related to how the needle has worn and altered. Statistical treatment was conducted using the Kruskal-Wallis H test to compare multiple values and the Mann-Whitney U test to compare pairs. A multi-stage regression model was applied with the aim of predicting the changes in the dependent variables based on the number and type of sutures performed. The incision plane ranged from 126.67 to 346.24μm among the different groups. The displaced area was measured as being between 14 524.83μm² and 128 311.91μm². The best predictive model for the incision plane obtained a coefficient of determination (R2) of 0.149, while it reached 0.249 for the displaced area. Subperiosteal sutures held more weighting among the variables studied. Mucosal sutures did not seem to greatly affect needle wear. Observations reported in this paper indicate that the needle should be changed after having performed two subperiosteal sutures, given the wear and change to the incision plane that is produced, which causes the needle’s cutting ability to reduce. Key words: Needles, sutures, material testing, oral surgery, third molar, scanning electron microscope. PMID:22157669

  6. Use of Barbed Sutures in Laparoscopic Gastrointestinal Single-Layer Sutures

    PubMed Central

    Kaji, Masahide; Kinoshita, Jun; Shimizu, Koichi

    2016-01-01

    Background and Objectives: Laparoscopic anastomotic methods are not commonly used because of the cumbersome laparoscopic intracorporeal sutures and tying involved. The barbed suture is one of the various devices developed to simplify the placement of intracorporeal sutures. However, barbed sutures are not commonly used during reconstruction after radical gastrectomy in cancer patients or for single-layer entire-thickness running suturing for intestinal anastomoses. We describe the procedure for using barbed sutures and report on the short-term surgical outcomes. Methods: Between August 2012 and March 2014, 15-cm-long barbed sutures (V-Loc 180; Covidien, Mansfield, MA, USA) were used for laparoscopic intestinal anastomoses, including intestinal hole closure for esophagojejunal and gastrojejunal anastomoses after mechanical anastomoses and gastric wall closure after partial resection. Results: In total, 38 patients underwent 40 laparoscopic anastomoses (esophagojejunostomies, 26; gastrojejunostomies, 7; and simple closure of gastric defect, 7); no cases required conversion to open surgery. Two cases exhibited positive air leak test results during surgery (1 case of esophagojejunostomy and 1 case of simple closure of gastric defect). Two cases of intestinal obstruction were noted; of those, one patient with postoperative intestinal paresis (grade II) was managed conservatively, and the other underwent repeat laparoscopic surgery (grade IIIb) for internal herniation unrelated to V-Loc use. No postoperative complications at the anastomosis site and no surgery-related deaths were noted. Conclusion: Single-layer entire-thickness running suturing with the V-Loc 180 barbed suture after stapled side-to-side intestinal anastomosis was found to be safe and feasible in the reported cases. PMID:27493467

  7. Ingress of water into solid nylon 6.6

    NASA Astrophysics Data System (ADS)

    Mansfield, P.; Bowtell, R.; Blackband, S.

    The ingress of water into Nylon 6.6 has been studied over a range of temperatures by nuclear magnetic resonance imaging techniques. The results have been used to extract the translational diffusion coefficient as a function of water concentration for various temperatures. These results in turn allow the activation energies to be evaluated. Other experiments have been made to measure the spin relaxation times T1 and T2. The results are interpreted using a two-phase exchange model from which good agreement for both the diffusion and relaxation-time data is obtained. High-pressure diffusion results also presented support the view that water is taken up preferentially at the amorphous amide sites in the Nylon and that pressure increases serve to force water onto sitccupied sites and/or onto occupied sites, giving up to three waters per amide site.

  8. Nylon-sputtered nanoparticles: fabrication and basic properties

    NASA Astrophysics Data System (ADS)

    Polonskyi, O.; Kylián, O.; Solař, P.; Artemenko, A.; Kousal, J.; Slavínská, D.; Choukourov, A.; Biederman, H.

    2012-12-01

    Nylon-sputtered nanoparticles were prepared using a simple gas aggregation cluster source based on a planar magnetron (Haberland type) and equipped with a nylon target. Plasma polymer particles originated in an aggregation chamber and travelled to a main (deposition) chamber with a gas flow through an orifice. The deposited nanoparticles were observed to have a cauliflower-like structure. The nanoparticles were found to be nitrogen-rich with N/C ratio close to 0.5. An increase in rf power from 60 to 100 W resulted in a decrease in mean particle size from 210 to 168 nm whereas an increase in their residence time in the cluster source from 0.7 to 4.6 s resulted in an increase in the size from 73 to 231 nm.

  9. Summary of aging effects on 25-year old nylon parachutes

    SciTech Connect

    Tadios, E.L.

    1988-01-01

    Structural evaluations were conducted on several parachute systems to determine the effects of aging on parachute materials. Most of the parachutes were 25 years old. Five 64 ft parachutes were evaluated along with one 4 ft guide surface parachute and three 16.5 ft ribbon parachutes. The parachute systems used in the study were all fabricated from nylon materials. Results were obtained for several material properties such as tensile strength, air permeability and melting point. Military specifications were used as zero-time data base due to lack of raw material data. The results indicate that over a period of about 25 years, parachute nylon materials do not degrade to unacceptable levels. 7 refs., 2 figs., 3 tabs.

  10. Polyamides based on the renewable monomer, 1,13-tridecane diamine II: Synthesis and characterization of nylon 13,6

    SciTech Connect

    Samanta, Satyabrata; He, Jie; Selvakumar, Sermadurai; Lattimer, Jessica; Ulven, Chad; Sibi, Mukund; Bahr, James; Chisholm, Bret J.

    2012-12-19

    The nylon 13,6 was successfully synthesized and its chemical composition, thermal properties, crystal structure, and moisture absorption characterized. Melting temperature and glass transition temperature were determined to be 206 °C and 60 °C, respectively, while the equilibrium melting temperature was determined to be 248 °C. Characterization of the crystallization kinetics showed that nylon 13,6 exhibits very fast crystallization compared to the industrially important nylons, nylon 6 and nylon 6,6. Additionally, the moisture absorption of nylon 13,6 was dramatically lower than nylon 6 and nylon 6,6 which is consistent with the much lower amide content of nylon 13,6. The crystal structure was determined to be different from the expected γ-form, which possess a pseudohexagonal unit cell. Instead, the x-ray scattering pattern was more similar to the α-form. Furthermore, a similar result has been obtained for other odd–even nylons including nylon 5,6, nylon 5,10, nylon 9,2, nylon 11,10, and nylon 11,12.

  11. Polyamides based on the renewable monomer, 1,13-tridecane diamine II: Synthesis and characterization of nylon 13,6

    DOE PAGESBeta

    Samanta, Satyabrata; He, Jie; Selvakumar, Sermadurai; Lattimer, Jessica; Ulven, Chad; Sibi, Mukund; Bahr, James; Chisholm, Bret J.

    2012-12-19

    The nylon 13,6 was successfully synthesized and its chemical composition, thermal properties, crystal structure, and moisture absorption characterized. Melting temperature and glass transition temperature were determined to be 206 °C and 60 °C, respectively, while the equilibrium melting temperature was determined to be 248 °C. Characterization of the crystallization kinetics showed that nylon 13,6 exhibits very fast crystallization compared to the industrially important nylons, nylon 6 and nylon 6,6. Additionally, the moisture absorption of nylon 13,6 was dramatically lower than nylon 6 and nylon 6,6 which is consistent with the much lower amide content of nylon 13,6. The crystal structuremore » was determined to be different from the expected γ-form, which possess a pseudohexagonal unit cell. Instead, the x-ray scattering pattern was more similar to the α-form. Furthermore, a similar result has been obtained for other odd–even nylons including nylon 5,6, nylon 5,10, nylon 9,2, nylon 11,10, and nylon 11,12.« less

  12. Advances in Suture Material for Obstetric and Gynecologic Surgery

    PubMed Central

    Greenberg, James A; Clark, Rachel M

    2009-01-01

    Despite millennia of experience with wound closure biomaterials, no study or surgeon has yet identified the perfect suture for all situations. Tissue characteristics, tensile strength, reactivity, absorption rates, and handling properties should be taken into account when selecting a wound closure suture. This review discusses the wound healing process and the biomechanical properties of currently available suture materials to better understand how to choose suture material in obstetrics and gynecology. PMID:19826572

  13. Kinetics for the degradation of nylon and Kevlar parachute materials

    SciTech Connect

    Auerbach, I.

    1986-01-01

    The degradation of nylon 66 and Kevlar 29 yarns at elevated temperatures and over a broad range of humidities was studied and a rate relationship developed which models the degradation and permits computation of rate constants. The degradation rates are slow initially due to the presence of an inhibitor but increase rapidly as the inhibitor is depleted. The effect of relative humidity (RH) can be very large especially at values in the 100% range. An exponential relationship exists for nylon between the rate constant and RH. Kinetic parameters were evaluated and the rate constants at 25/sup 0/C calculated. These values showed that the tensile strength of nylon 66 will remain at a safe level over a 25-year period if the humidity is maintained at the 10% range or less. Kevlar 29 is more resistant and can tolerate humidity levels in the range of 90% or less. Degradation is governed by thermal-oxidative and moisture induced mechanisms. At the very high humidities the moisture induced degradation predominates. A relationship is developed which predicts the degradation rate over a very broad range of temperatures and humidities.

  14. Simple suture and anchor in rabbit hips

    PubMed Central

    Garcia Filho, Fernando Cal; Guarniero, Roberto; de Godoy Júnior, Rui Maciel; Pereira, César Augusto Martins; Matos, Marcos Almeida; Garcia, Lucas Cortizo

    2012-01-01

    Objective Using biomechanical studies, this research aims to compare hip capsulorrhaphy in rabbits, carried out with two different techniques: capsulorrhaphy with simple sutures and with anchors. Method Thirteen New Zealand Albino (Oryctolaguscuniculus) male rabbits, twenty-six hip joints, were used. First, a pilot project was performed with three rabbits (six hip joints). This experiment consisted of ten rabbits divided into two groups: group 1 underwent capsulorrhaphy on both right and left hips with simple suture using polyglycolic acid absorbable thread, and group 2 underwent capsulorrhaphy with titanium anchors. After a four-week postoperative period, the animals were euthanized and the hip joints were frozen. On the same day of the biomechanical studies, after the hip joints were previously unfrozen, the following parameters were evaluated: rigidity, maximum force, maximum deformity and energy. Results There was no relevant statistical difference in rigidity, maximum force, maximum deformity and energy between the simple suture and anchor groups. Conclusion Through biomechanical analyses, using parameters of rigidity, maximum force, maximum deformity and energy, it has been shown that capsulorrhaphy with simple suture and with anchors has similar results in rabbit hip joints. Level of Evidence II, Prospective Comparative Study. PMID:24453618

  15. Bone cement improves suture anchor fixation.

    PubMed

    Giori, Nicholas J; Sohn, David H; Mirza, Faisal M; Lindsey, Derek P; Lee, Arthur T

    2006-10-01

    Suture anchor fixation failure can occur if the anchor pulls out of bone. We hypothesized that suture anchor fixation can be augmented with polymethylmethacrylate cement, and that polymethylmethacrylate can be used to improve fixation in a stripped anchor hole. Six matched cadaveric proximal humeri were used. On one side, suture anchors were placed and loaded to failure using a ramped cyclic loading protocol. The stripped anchor holes then were injected with approximately 1 cc polymethylmethacrylate, and anchors were replaced and tested again. In the contralateral humerus, polymethylmethacrylate was injected into anchor holes before anchor placement and testing. In unstripped anchors, polymethylmethacrylate increased the number of cycles to failure by 34% and failure load by 71% compared with anchors not augmented with polymethylmethacrylate. Polymethylmethacrylate haugmentation of stripped anchors increased the cycles to failure by 31% and failure load by 111% compared with unstripped uncemented anchors. No difference was found in cycles to failure or failure load between cemented stripped anchors and cemented unstripped anchors. Polymethylmethacrylate can be used to augment fixation, reducing the risk of anchor pull-out failure, regardless whether the suture anchor hole is stripped or unstripped. PMID:16702922

  16. Aortic valve annuloplasty: new single suture technique.

    PubMed

    Schöllhorn, Joachim; Rylski, Bartosz; Beyersdorf, Friedhelm

    2014-06-01

    Reconstruction strategies for aortic valve insufficiency in the presence of aortic annulus dilatation are usually surgically challenging. We demonstrate a simple, modified Taylor technique of downsizing and stabilization of the aortic annulus using a single internal base suture. Since April 2011, 22 consecutive patients have undergone safe aortic valve annuloplasty. No reoperations for aortic valve insufficiency and no deaths occurred. PMID:24882316

  17. Biomechanical Dynamics of Cranial Sutures during Simulated Impulsive Loading

    PubMed Central

    Zhang, Z. Q.; Yang, J. L.

    2015-01-01

    Background. Cranial sutures are deformable joints between the bones of the skull, bridged by collagen fibres. They function to hold the bones of the skull together while allowing for mechanical stress transmission and deformation. Objective. The aim of this study is to investigate how cranial suture morphology, suture material property, and the arrangement of sutural collagen fibres influence the dynamic responses of the suture and surrounding bone under impulsive loads. Methods. An idealized bone-suture-bone complex was analyzed using a two-dimensional finite element model. A uniform impulsive loading was applied to the complex. Outcome variables of von Mises stress and strain energy were evaluated to characterize the sutures' biomechanical behavior. Results. Parametric studies revealed that the suture strain energy and the patterns of Mises stress in both the suture and surrounding bone were strongly dependent on the suture morphologies. Conclusions. It was concluded that the higher order hierarchical suture morphology, lower suture elastic modulus, and the better collagen fiber orientation must benefit the stress attenuation and energy absorption. PMID:27019589

  18. Biomechanical Dynamics of Cranial Sutures during Simulated Impulsive Loading.

    PubMed

    Zhang, Z Q; Yang, J L

    2015-01-01

    Background. Cranial sutures are deformable joints between the bones of the skull, bridged by collagen fibres. They function to hold the bones of the skull together while allowing for mechanical stress transmission and deformation. Objective. The aim of this study is to investigate how cranial suture morphology, suture material property, and the arrangement of sutural collagen fibres influence the dynamic responses of the suture and surrounding bone under impulsive loads. Methods. An idealized bone-suture-bone complex was analyzed using a two-dimensional finite element model. A uniform impulsive loading was applied to the complex. Outcome variables of von Mises stress and strain energy were evaluated to characterize the sutures' biomechanical behavior. Results. Parametric studies revealed that the suture strain energy and the patterns of Mises stress in both the suture and surrounding bone were strongly dependent on the suture morphologies. Conclusions. It was concluded that the higher order hierarchical suture morphology, lower suture elastic modulus, and the better collagen fiber orientation must benefit the stress attenuation and energy absorption. PMID:27019589

  19. Recycling Suture Limbs from Knotless Suture Anchors for Arthroscopic Shoulder Stabilization

    PubMed Central

    Johnson, Timothy S.; DiPompeo, Christine M.; Ismaeli, Zahra C.; Porter, Polly A.; Nicholson, Shannon L.; Johnson, David C.

    2014-01-01

    Recurrent shoulder instability often leads to labral abnormality that requires surgical intervention that may require fixation with suture anchors. The proposed surgical technique allows the surgeon to achieve 2 points of fixation around the labrum and/or capsule with a single suture secured to the glenoid with a knotless anchor. Instead of cutting and discarding the residual suture limbs after anchor insertion, this technique uses the residual suture limbs of the knotless anchor for a second suture pass. This technique (1) creates a more cost- and time-efficient surgical procedure than using multiple single-loaded anchors or double-loaded anchors, (2) decreases the known risk of glenoid fracture from the stress riser at the implant tips of multi-anchor repairs by reducing the number of anchors required for stabilization, (3) decreases the surgical time compared with the use of double-loaded anchors through simpler suture management and less knot tying, (4) allows for the secure reapproximation of the labrum to the glenoid while offering a convenient option for capsulorrhaphy without the need to insert another anchor, and (5) yields more points of soft-tissue fixation with fewer anchors drilled into the glenoid. PMID:25126504

  20. The method of manufacture of nylon dental partially removable prosthesis using additive technologies

    NASA Astrophysics Data System (ADS)

    Kashapov, R. N.; Korobkina, A. I.; Platonov, E. V.; Saleeva, G. T.

    2014-12-01

    The article is devoted to the topic of creating new methods of dental prosthesis. The aim of this work is to investigate the possibility of using additive technology to create nylon prosthesis. As a result of experimental studies, was made a sample of nylon partially removable prosthesis using 3D printing has allowed to simplify, accelerate and reduce the coat of manufacturing high-precision nylon dentures.

  1. Transfascial suture in laparoscopic ventral hernia repair; friend or foe?

    PubMed

    Sahu, Diwakar; Das, Somak; Wani, Majid Rasool; Reddy, Prasanna Kumar

    2015-01-01

    'Suture hernia' is fairly a new and rare type of ventral hernia. It occurs at the site of transfascial suture, following laparoscopic ventral hernia repair (LVHR). Employment of transfascial sutures in LVHR is still debatable in contrast to tackers. Prevention of mesh migration and significant post-operative pain are the pros and cons with the use of transfascial sutures, respectively. We report an unusual case of suture hernia or transfascial hernia, which can further intensify this dispute, but at the same time will provide insight for future consensus. PMID:25883460

  2. Effect of Adhesive Strips and Dermal Sutures vs Dermal Sutures Only on Wound Closure

    PubMed Central

    Custis, Trenton; Armstrong, April W.; King, Thomas H.; Sharon, Victoria R.; Eisen, Daniel B.

    2016-01-01

    IMPORTANCE Although applying adhesive strips to a wound closure has been shown to have outcomes equivalent to those with cuticular suturing, it is unknown whether adhesive strips provide additional benefit compared with dermal suturing alone. OBJECTIVE To determine whether the addition of adhesive strips to a wound closed with buried interrupted subcuticular sutures improves outcomes following wound closure. DESIGN, SETTING, AND PARTICIPANTS A prospective, randomized split-wound intervention was conducted between November 14, 2013, and May 16, 2014, in patients who underwent cutaneous surgical procedures at the University of California, Davis, outpatient dermatology clinic. Fifty-seven patients 18 years or older with postoperative defects of at least 3 cm, resulting from either Mohs micrographic surgical procedures or surgical excision, were screened for participation. Nine patients were excluded and 48 were enrolled. INTERVENTIONS Half of each wound was randomized to receive buried interrupted subcuticular sutures and overlying adhesive strips and the other half received buried interrupted subcuticular sutures only. MAIN OUTCOMES AND MEASURES At 3 months’ follow-up, each patient and 2 blinded observers evaluated the wound using the Patient Observer Scar Assessment Scale. RESULTS The total mean (SD) Patient Observer Scar Assessment Scale score for observers for the side that received a combination of adhesive strips and buried interrupted subcuticular suturing (12.3 [4.8]) and the side that received sutures only (12.9 [6.3]) did not differ significantly at 3 months (P = .32). There was no significant difference in the total patient assessment scale score between the combination closure (14.0 [7.6]) and sutures only (14.7 [7.6]) sides at 3 months (P = .39). There was also no significant difference between the 2 closure methods in terms of mean (SD) scar width (both methods: 1.1 [0.8] mm, P = .89) at follow-up. CONCLUSIONS AND RELEVANCE Combination closure with

  3. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 1 2011-04-01 2011-04-01 false What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT OF LABOR FEDERAL EMPLOYEES' COMPENSATION ACT CLAIMS FOR COMPENSATION UNDER THE FEDERAL...

  4. 20 CFR 10.0 - What are the provisions of the FECA, in general?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 1 2013-04-01 2012-04-01 true What are the provisions of the FECA, in general? 10.0 Section 10.0 Employees' Benefits OFFICE OF WORKERS' COMPENSATION PROGRAMS, DEPARTMENT OF LABOR FEDERAL EMPLOYEES' COMPENSATION ACT CLAIMS FOR COMPENSATION UNDER THE FEDERAL...

  5. Effect of suture material on platelet deposition onto prosthetic material

    SciTech Connect

    Connolly, R.; McEnroe, C.S.; Li, S.; Coleman, J.; Callow, A.D.

    1988-07-01

    Previous studies have demonstrated the importance of employing prosthetic material with minimal thrombogenicity. However, the role of different suture materials in early thrombotic events on prosthetic materials has not been examined. Experiments were designed to analyze the effects of suture on platelet graft interaction using an in vivo baboon hemocompatability screen. Indium labeled, autologous platelet deposition was determined on expanded polytetrafluoroethylene (ePTFE) containing suture lines of polypropylene (Prolene), polybutester (Novafil), and ePTFE (Gore-Tex). A significant increase in platelet deposition was noted not only at the suture line, but proximal and distal to it as well. The results were different for each of the sutures employed and suggest that the suture line may influence early platelet deposition in the perianastomotic region, not only at the suture line, but proximally and distally as well.

  6. [Dissertations 25 years after date 26. Maxillary sutural surfaces].

    PubMed

    Remmelink, H J

    2011-06-01

    In the case of growing children with a deviation in the size or position of the upper jaw orthopaedic devices are often used to direct the growth at the level of the sutures. In the PhD thesis 'The postnatal development of the human maxillary sutural surfaces', published in 1985, the orientation and macroscopic morphology of the sutural surfaces of the maxilla in children's skulls were described. The existence of premaxillomaxillary and pterygomaxillary sutures could not be demonstrated. It was observed that the maxillary sutural surfaces were mainly sagittally oriented. Some sutural surfaces became increasingly rough with age, while the majority of the surfaces remained smooth. It was concluded that advice concerning the determination of the direction of orthopaedic forces in relation to the orientation of the sutures needed revision. Subsequent systematic reviews have reported that so far little is known about the long-term stability of orthopaedic effects in orthodontics. PMID:21761798

  7. Craniofacial Sutures: Morphology, Growth, and In Vivo Masticatory Strains

    PubMed Central

    RAFFERTY, KATHERINE L.; HERRING, SUSAN W.

    2010-01-01

    The growth and morphology of craniofacial sutures are thought to reflect their functional environment. However, little is known about in vivo sutural mechanics. The present study investigates the strains experienced by the internasal, nasofrontal, and anterior interfrontal sutures during masticatory activity in 4–6-month-old miniature swine (Sus scrofa). Measurements of the bony/fibrous arrangements and growth rates of these sutures were then examined in the context of their mechanical environment. Large tensile strains were measured in the interfrontal suture (1,036 με ± 400 SD), whereas the posterior internasal suture was under moderate compression (−440 με ± 238) and the nasofrontal suture experienced large compression (−1,583 με ± 506). Sutural interdigitation was associated with compressive strain. The collagen fibers of the internasal and interfrontal sutures were clearly arranged to resist compression and tension, respectively, whereas those of the nasofrontal suture could not be readily characterized as either compression or tension resisting. The average linear rate of growth over a 1-week period at the nasofrontal suture (133.8 μm, ± 50.9 S.D) was significantly greater than that of both the internasal and interfrontal sutures (39.2 μm ± 11.4 and 65.5 μm ± 14.0, respectively). Histological observations suggest that the nasofrontal suture contains chondroid tissue, which may explain the unexpected combination of high compressive loading and rapid growth in this suture. PMID:10521876

  8. Skin tension related to tension reduction sutures.

    PubMed

    Hwang, Kun; Kim, Han Joon; Kim, Kyung Yong; Han, Seung Ho; Hwang, Se Jin

    2015-01-01

    The aim of this study was to compare the skin tension of several fascial/subcutaneous tensile reduction sutures. Six upper limbs and 8 lower limbs of 4 fresh cadavers were used. At the deltoid area (10 cm below the palpable acromion) and lateral thigh (midpoint from the palpable greater trochanter to the lateral border of the patella), and within a 3 × 6-cm fusiform area of skin, subcutaneous tissue defects were created. At the midpoint of the defect, a no. 5 silk suture was passed through the dermis at a 5-mm margin of the defect, and the defect was approximated. The initial tension to approximate the margins was measured using a tensiometer.The tension needed to approximate skin without any tension reduction suture (S) was 6.5 ± 4.6 N (Newton). The tensions needed to approximate superficial fascia (SF) and deep fascia (DF) were 7.8 ± 3.4 N and 10.3 ± 5.1 N, respectively. The tension needed to approximate the skin after approximating the SF was 4.1 ± 3.4 N. The tension needed to approximate the skin after approximating the DF was 4.9 ± 4.0 N. The tension reduction effect of approximating the SF was 38.8 ± 16.4% (2.4 ± 1.5 N, P = 0.000 [ANOVA, Scheffé]). The tension reduction effect of approximating the DF was 25.2% ± 21.9% (1.5 ± 1.4 N, P = 0.001 [ANOVA, Scheffé]). The reason for this is thought to be that the SF is located closely to the skin unlike the DF. The results of this study might be a basis for tension reduction sutures. PMID:25569413

  9. Validation of the nylon flocked swab for planetary protection applications

    NASA Astrophysics Data System (ADS)

    Moissl-Eichinger, Christine; Probst, Alexander

    The major issue of planetary protection is to prevent the contamination of extraterrestrial en-vironments by terrestrial biomolecules and life forms. In order not to affect or even to confound future life detection missions on celestial bodies, which are of interest for their chemical and bi-ological evolution, spacecraft are constructed in clean rooms and are subject to severe cleaning processes and microbiological controls before launch. Microbiological assays are used to mea-sure and control the bioburden on spacecraft itself and spacecraft hardware during assembly. The current NASA standard assays have originally been developed for the Viking programme in the 70s. Due to the stringent contamination control constrains of the upcoming ESA Ex-oMars mission, these protocols cannot be used, in particular the application of cotton swabs with wooden applicators is no longer possible. Therefore, cotton swabs will be replaced by the novel nylon flocked swabs. In the study presented here, the nylon flocked swabs were validated for the usage for measuring and controling of the bioburden on spacecraft related surfaces. The absolute recovery efficiency was determined, following the guidelines of USP1223 in preci-sion, accuracy, robustness, specificity, linearity and limit of detection. As a standard surface, stainless steel coupons were used, whereas B. atrophaeus (spores) served as standard microbial strain. Additionally, the nylon flocked swab was used for experiments on different rough and smooth surfaces with seven different Bacillus spores and two different protocols. Further details will be given concerning the new ESA standard swab procedure for the microbial examination of flight hardware and clean rooms to be used for the upcoming ExoMars mission.

  10. Coracoclavicular stabilization using a suture anchor technique.

    PubMed

    Friedman, Darren J; Barron, O Alton; Catalano, Louis; Donahue, Joseph P; Zambetti, George

    2008-06-01

    Multiple fixation options exist for coracoclavicular stabilization, but many are technically demanding and require hardware removal. In the study reported here, we reviewed a specific fixation technique that includes suture anchors moored in the base of the coracoid process. We retrospectively reviewed 24 consecutive cases of patients who underwent coracoclavicular stabilization with a suture anchor for a type III or type V acromioclavicular (AC) joint separation or a group II, type II or type V distal clavicle fracture. Eighteen of the 22 patients had full strength and painless range of motion (ROM) in the affected extremity by 3 months and at final follow-up (minimum, 24 months; mean, 39 months). Two patients were lost to follow-up. Four patients had early complications likely secondary to documented noncompliance. Two of these 4 patients underwent reoperation with a similar procedure and remained asymptomatic at a minimum follow-up of 15 months. One patient underwent osteophyte and knot excision 7 months after surgery and remained asymptomatic at 30 months. Our results suggest that coracoclavicular stabilization using a suture anchor technique is a safe and reliable method of treating acromioclavicular joint separations and certain distal clavicle fractures in the compliant patient. PMID:18716693

  11. Safety assessment of nylon as used in cosmetics.

    PubMed

    Burnett, Christina; Heldreth, Bart; Bergfeld, Wilma F; Belsito, Donald V; Hill, Ronald A; Klaassen, Curtis D; Liebler, Daniel C; Marks, James G; Shank, Ronald C; Slaga, Thomas J; Snyder, Paul W; Andersen, F Alan

    2014-01-01

    The Cosmetic Ingredient Review Expert Panel (Panel) reviewed the safety of nylon polymers, which function in cosmetics primarily as bulking and opacifying agents. The Panel reviewed relevant animal and human data related to these large polymers and determined that they are not likely to penetrate the skin. Whatever residual monomers may be present were not present at a sufficient level to cause any reactions in test subjects at the maximum ingredient use concentration. Accordingly, the Panel concluded that these ingredients are safe in the present practices of use and concentration. PMID:25568165

  12. Low background techniques for the Borexino nylon vessels

    SciTech Connect

    Pocar, Andrea

    2005-09-08

    Borexino is an organic liquid scintillator underground detector for low energy solar neutrinos. The experiment has to satisfy extremely stringent low background requirements. The thin nylon spherical scintillator containment vessel has to meet cleanliness and low radioactivity levels second only, within the detector, to the scintillator itself. Overall, the background from the vessel in the fiducial volume of the detector must be kept at the level of one event per day or better. The requirements, design choices, results from laboratory tests, and fabrication techniques that have been adopted to meet this goal are presented. Details of the precautions taken during the installation of the vessels inside the Borexino detector are also discussed.

  13. Nylon-3 Polymers that Enable Selective Culture of Endothelial Cells

    PubMed Central

    Liu, Runhui; Chen, Xinyu; Gellman, Samuel H.; Masters, Kristyn S.

    2014-01-01

    Substrates that selectively encourage the growth of specific cell types are valuable for the engineering of complex tissues. Some cell-selective peptides have been identified from extracellular matrix proteins; these peptides have proven useful for biomaterials-based approaches to tissue repair or regeneration. However, there are very few examples of synthetic materials that display selectivity in supporting cell growth. We describe nylon-3 polymers that support in vitro culture of endothelial cells, but do not support the culture of smooth muscle cells or fibroblasts. These materials may be promising for vascular biomaterials applications. PMID:24156536

  14. Cranial suture biology of the Aleutian Island inhabitants.

    PubMed

    Cray, James; Mooney, Mark P; Siegel, Michael I

    2011-04-01

    Research on cranial suture biology suggests there is biological and taxonomic information to be garnered from the heritable pattern of suture synostosis. Suture synostosis along with brain growth patterns, diet, and biomechanical forces influence phenotypic variability in cranial vault morphology. This study was designed to determine the pattern of ectocranial suture synostosis in skeletal populations from the Aleutian Islands. We address the hypothesis that ectocranial suture synostosis pattern will differ according to cranial vault shape. Ales Hrdlicka identified two phenotypes in remains excavated from the Aleutian Island. The Paleo-Aleutians, exhibiting a dolichocranic phenotype with little prognathism linked to artifacts distinguished from later inhabitants, Aleutians, who exhibited a brachycranic phenotype with a greater amount of prognathism. A total of 212 crania representing Paleo-Aleuts and Aleutian as defined by Hrdlicka were investigated for suture synostosis pattern following standard methodologies. Comparisons were performed using Guttmann analyses. Results revealed similar suture fusion patterns for the Paleo-Aleut and Aleutian, a strong anterior to posterior pattern of suture fusion for the lateral-anterior suture sites, and a pattern of early termination at the sagittal suture sites for the vault. These patterns were found to differ from that reported in the literature. Because these two populations with distinct cranial shapes exhibit similar patterns of suture synostosis it appears pattern is independent of cranial shape in these populations of Homo sapiens. These findings suggest that suture fusion patterns may be population dependent and that a standardized methodology, using suture fusion to determine age-at-death, may not be applicable to all populations. PMID:21328563

  15. Fiber from ramie plant (Boehmeria nivea): A novel suture biomaterial.

    PubMed

    Kandimalla, Raghuram; Kalita, Sanjeeb; Choudhury, Bhaswati; Devi, Dipali; Kalita, Dhaneswar; Kalita, Kasturi; Dash, Suvakanta; Kotoky, Jibon

    2016-05-01

    The quest for developing an ideal suture material prompted our interest to develop a novel suture with advantageous characters to market available ones. From natural origin only silk, cotton and linen fibers are presently available in market as non-absorbable suture biomaterials. In this study, we have developed a novel, cost-effective, and biocompatible suture biomaterial from ramie plant, Boehmeria nivea fiber. Field emission scanning electron microscopy (FE-SEM), energy-dispersive X-ray spectroscopy (EDX), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR) and thermo gravimetric analysis (TGA) results revealed the physicochemical properties of raw and degummed ramie fiber, where the former one showed desirable characteristics for suture preparation. The braided multifilament ramie suture prepared from degummed fiber exhibited excellent tensile strength. The suture found to be biocompatible towards human erythrocytes and nontoxic to mammalian cells. The fabricated ramie suture exhibited significant antibacterial activity against Escherichia coli, Bacillus subtilis and Staphylococcus aureus; which can be attributed to the inherent bacteriostatic ability of ramie plant fiber. In vivo wound closure efficacy was evaluated in adult male wister rats by suturing the superficial wound incisions. Within seven days of surgery the wound got completely healed leaving no rash and scar. The role of the ramie suture in complete wound healing was supported by the reduced levels of serum inflammatory mediators. Histopathology studies confirmed the wound healing ability of ramie suture, as rapid synthesis of collagen, connective tissue and other skin adnexal structures were observed within seven days of surgery. Tensile properties, biocompatibility and wound closure efficacy of the ramie suture were comparable with market available BMSF suture. The outcome of this study can drive tremendous possibility for the utilization of ramie plant fiber for

  16. Knotless anchors with sutures external to the anchor body may be at risk for suture cutting through osteopenic bone

    PubMed Central

    Ono, Y.; Woodmass, J. M.; Nelson, A. A.; Boorman, R. S.; Thornton, G. M.

    2016-01-01

    Objectives This study evaluated the mechanical performance, under low-load cyclic loading, of two different knotless suture anchor designs: sutures completely internal to the anchor body (SpeedScrew) and sutures external to the anchor body and adjacent to bone (MultiFIX P). Methods Using standard suture loops pulled in-line with the rotator cuff (approximately 60°), anchors were tested in cadaveric bone and foam blocks representing normal to osteopenic bone. Mechanical testing included preloading to 10 N and cyclic loading for 500 cycles from 10 N to 60 N at 60 mm/min. The parameters evaluated were initial displacement, cyclic displacement and number of cycles and load at 3 mm displacement relative to preload. Video recording throughout testing documented the predominant source of suture displacement and the distance of ‘suture cutting through bone’. Results In cadaveric bone and foam blocks, MultiFIX P anchors had significantly greater initial displacement, and lower number of cycles and lower load at 3 mm displacement than SpeedScrew anchors. Video analysis revealed ‘suture cutting through bone’ as the predominant source of suture displacement in cadaveric bone (qualitative) and greater ‘suture cutting through bone’ comparing MultiFIX P with SpeedScrew anchors in foam blocks (quantitative). The greater suture displacement in MultiFIX P anchors was predominantly from suture cutting through bone, which was enhanced in an osteopenic bone model. Conclusions Anchors with sutures external to the anchor body are at risk for suture cutting through bone since the suture eyelet is at the distal tip of the implant and the suture directly abrades against the bone edge during cyclic loading. Suture cutting through bone may be a significant source of fixation failure, particularly in osteopenic bone. Cite this article: Y. Ono, J. M. Woodmass, A. A. Nelson, R. S. Boorman, G. M. Thornton, I. K. Y. Lo. Knotless anchors with sutures external to the anchor body may be

  17. Development of rapid continuous dyeing process for heavy-weight nylon 6,6 carpet

    Technology Transfer Automated Retrieval System (TEKTRAN)

    An improved continuous dyeing process for coloration of heavy-weight (60-70 oz/yd2), residential nylon 6,6 carpet is reported. By inserting a slot steam applicator after the dye pad and before the box steamer to preheat the carpet to around 180°F (greater than the nylon wet glass transition temperat...

  18. Applications of nylon membrane arrays to gene expression analysis.

    PubMed

    Cox, J M

    2001-04-01

    Gene expression analyses by hybridization of probes derived from mRNA to cDNA targets arrayed on a nylon membranes have been performed with increasing frequency and success over the last decade. While the initial costs of generating arrays are moderately high, they are now available commercially as complete packages which include the membranes and associated image analysis software for acquisition and processing of the data. Arrays can be used to generate information concerning the expression of mRNA from cells treated with various agents or from different tissues, e.g. comparing diseased with normal controls. To date, many groups, including immunologists, have used this technology to examine gene expression within their area of biological interest. The main characteristic of these systems is the large amount of data generated, since the expression of many thousands of genes are measured in parallel. The main practical issues are sensitivity of detection, reproducibility, comparability with other systems (e.g. Northern blots) and processing of data. Some of the significant applications of nylon array technology to date are reviewed in this chapter, and with these issues in mind, we include a discussion of our own experiences in this area. PMID:11251218

  19. Loss of Fine Particle Ammonium from Denuded Nylon Filters

    SciTech Connect

    Yu, Xiao-Ying; Lee, Taehyoung; Ayres, Benjamin; Kreidenweis, Sonia M.; Malm, William C.; Collett, Jeffrey L.

    2006-08-01

    Ammonium is an important constituent of fine particulate mass in the atmosphere, but can be difficult to quantify due to possible sampling artifacts. Losses of semivolatile species such as NH4NO3 can be particularly problematic. In order to evaluate ammonium losses from aerosol particles collected on filters, a series of field experiments was conducted using denuded nylon and Teflon filters at Bondville, Illinois (February 2003), San Gorgonio, California (April 2003 and July 2004), Grand Canyon National Park, Arizona (May, 2003), Brigantine, New Jersey (November 2003), and Great Smoky Mountains National Park (NP), Tennessee (July–August 2004). Samples were collected over 24-hr periods. Losses from denuded nylon filters ranged from 10% (monthly average) in Bondville, Illinois to 28% in San Gorgonio, California in summer. Losses on individual sample days ranged from 1% to 65%. Losses tended to increase with increasing diurnal temperature and relative humidity changes and with the fraction of ambient total N(--III) (particulate NH4+ plus gaseous NH3) present as gaseous NH3. The amount of ammonium lost at most sites could be explained by the amount of NH4NO3 present in the sampled aerosol. Ammonium losses at Great Smoky Mountains NP, however, significantly exceeded the amount of NH4NO3 collected. Ammoniated organic salts are suggested as additional important contributors to observed ammonium loss at this location.

  20. Nylon coil actuator operating temperature range and stiffness

    NASA Astrophysics Data System (ADS)

    Kianzad, Soheil; Pandit, Milind; Bahi, Addie; Rafie Ravandi, Ali; Ko, Frank; Spinks, Geoffrey M.; Madden, John D. W.

    2015-04-01

    Components in automotive and aerospace applications require a wide temperature range of operation. Newly discovered thermally active Baughman muscle potentially provides affordable and viable solutions for driving mechanical devices by heating them from room temperature, but little is known about their operation below room temperature. We study the mechanical behavior of nylon coil actuators by testing elastic modulus and by investigating tensile stroke as a function of temperature. Loads that range from 35 MPa to 155 MPa were applied. For the nylon used and the coiling conditions, active thermal contraction totals 19.5 % when the temperature is raised from -40 °C to 160 °C. The thermal contraction observed from -40 °C to 20°C is only ~2 %, whereas between 100 and 160 °C the contraction is 10 %. A marked increase in thermal contraction is occurs in the vicinity of the glass transition temperature (~ 45°C). The elastic modulus drops as temperature increases, from ~155 MPa at - 40 °C to 35 MPa at 200 °C. Interestingly the drop in active contraction with increasing load is small and much less than might be expected given the temperature dependence of modulus.

  1. Bioactivity of degradable polymer sutures coated with bioactive glass.

    PubMed

    Bretcanu, Oana; Verné, Enrica; Borello, Luisa; Boccaccini, Aldo R

    2004-08-01

    Novel bioactive materials have been prepared by coating violet resorbable Vicryl sutures with a bioactive glass powder derived from a co-precipitation method. Two techniques have been chosen for the composite preparation: pressing the sutures in a bed of glass powder and slurry-dipping of sutures in liquid suspensions of bioactive glass powders. The uniformity and thickness of the coatings obtained by the two methods were compared. The bioactivity of the sutures with and without bioactive glass coating was tested by soaking in an inorganic acellular simulated body fluid (SBF). The composite sutures were characterised by XRD, SEM and FTIR analyses before and after soaking in SBF solution to assess the formation of hydroxyapatite on their surfaces, which is a qualitative measure of their bioactivity. The possible use of bioactive sutures to produce tissue engineering scaffolds and as reinforcement of resorbable calcium phosphates is discussed. PMID:15477741

  2. Evaluation of overcharge protection life in nickel cadmium cells with non-nylon separators

    SciTech Connect

    Scoles, D.L.; Johnson, Z.W.; Hayden, J.W.; Pickett, D.F. Jr.

    1997-12-01

    Hydrogen gassing and the potential for cell rupture in aerospace nickel cadmium cells is directly related to loss of overcharge protection built into the cell during manufacturing. It is well known that cells having nylon separators contribute to this loss via a hydrolysis reaction of the nylon in the potassium hydroxide electrolyte environment in the cell. The hydrolysis reaction produces lower chain organics which are oxidized by the positive electrode and oxygen. Oxidation of the organics diminishes the overcharge protection. With introduction of the Super NiCd and the Magnum nickel cadmium cells the nylon hydrolysis reaction is eliminated, but any reducing agent in the cell such as nickel or an organic additive can contribute to loss of overcharge protection. The present effort describes analyses made to evaluate the extent of overcharge protection loss in cells which do not have nylon hydrolysis and quantifies the diminished amount of overcharge protection loss as a result of eliminating nylon from aerospace cells.

  3. Mechanics of cranial sutures during simulated cyclic loading.

    PubMed

    Jasinoski, S C; Reddy, B D

    2012-07-26

    Previous computational and experimental analyses revealed that cranial sutures, fibrous joints between the bones, can reduce the strain experienced by the surrounding skull bones during mastication. This damping effect reflects the importance of including sutures in finite element (FE) analyses of the skull. Using the FE method, the behaviour of three suture morphologies of increasing complexity (butt-ended, moderate interdigitated, and complex interdigitated) during static loading was recently investigated, and the sutures were assumed to have linear elastic properties. In the current study, viscoelastic properties, derived from published experimental results of the nasofrontal suture of young pigs (Sus scrofa), are applied to the three idealised bone-suture models. The effects of suture viscoelasticity on the stress, strain, and strain energy in the models were computed for three different frequencies (corresponding to periods of 1, 10, and 100s) and compared to the results of a static, linear elastic analysis. The range of applied frequencies broadly represents different physiological activities, with the highest frequency simulating mastication and the lowest frequency simulating growth and pressure of the surrounding tissues. Comparing across all three suture morphologies, strain energy and strain in the suture decreased with the increase in suture complexity. For each suture model, the magnitude of strain decreased with an increase in frequency, and the magnitudes were similar for both the elastic and 1s frequency analyses. In addition, a viscous response is less apparent in the higher frequency analyses, indicating that viscous properties are less important to the behaviour of the suture during those analyses. The FE results suggest that implementation of viscoelastic properties may not be necessary for computational studies of skull behaviour during masticatory loading but instead might be more relevant for studies examining lower frequency physiological

  4. The Use of Barbed Sutures in Obstetrics and Gynecology

    PubMed Central

    Greenberg, James A

    2010-01-01

    Despite the multitude of different procedures performed with a host of different wound closure biomaterials, no study or surgeon has yet identified the perfect suture for all situations. In recent years, a new class of suture material—barbed suture—has been introduced into the surgeon’s armamentarium. This review focuses on barbed suture to better understand the role of this newer material in obstetrics and gynecology. PMID:21364859

  5. Multifunctional ZnO/Nylon 6 nanofiber mats by an electrospinning– electrospraying hybrid process for use in protective applications

    Technology Transfer Automated Retrieval System (TEKTRAN)

    ZnO/Nylon 6 nanofiber mats were prepared by an electrospinning–electrospraying hybrid process in which ZnO nanoparticles were dispersed on the surface of Nylon 6 nanofibers without becoming completely embedded. The prepared ZnO/Nylon 6 nanofiber mats were evaluated for their abilities to kill bacter...

  6. Arthroscopic all-inside lateral meniscus suture using posterolateral portal.

    PubMed

    Ahn, Jin Hwan; Oh, Irvin

    2006-05-01

    A new arthroscopic all-inside suture for lateral meniscus posterior horn tear using a single posterolateral portal is described. A lateral meniscus posterior horn peripheral longitudinal tear is often seen with anterior cruciate ligament injury or discoid lateral meniscus tear. Conventional repair methods, such as arthroscopic inside-out, outside-in, or all-inside sutures, can be cumbersome and technically demanding. Our all-inside suture using the posterolateral portal allows thorough visualization of the posterolateral structures, excellent coaptation of torn meniscus, strong knot tightening, and avoidance of inadvertent cartilage injury. The arthroscope is inserted through the anteromedial portal and reaches the posterolateral compartment by a transcondylar approach. A suture hook is introduced into the posterolateral portal without a cannula, penetrates posterior peripheral rim, crosses the tear, and passes through mobile torn fragment. A large amount of No. 0 PDS is passed, so that it curls up inside the joint. After the suture hook is removed, a suture retriever is inserted through the posterolateral portal to pull out 2 ends of the PDS at the same time. The retrieved suture ends are passed through a knot pusher and a 5.5-mm cannula is introduced over the retrieved suture materials for the SMC knot to be tied. A longitudinal tear of lateral meniscus posterior horn is repaired with 2 to 3 sutures. PMID:16651176

  7. Heterochrony and patterns of cranial suture closure in hystricognath rodents

    PubMed Central

    Wilson, Laura A B; Sánchez-Villagra, Marcelo R

    2009-01-01

    Sutures, joints that allow one bone to articulate with another through intervening fibrous connective tissue, serve as major sites of bone expansion during postnatal craniofacial growth in the vertebrate skull and represent an aspect of cranial ontogeny which may exhibit functional and phylogenetic correlates. Suture evolution among hystricognath rodents, an ecologically diverse group represented here by 26 species, is examined using sequence heterochrony methods, i.e. event pairing and parsimov. Although minor nuances in suture closure sequence exist between species, the overall sequence was found to be conserved both across the hystricognath group and, to an increasing degree, within selected clades. At species level, suture closure pattern exhibited a significant positive correlation with patterns previously reported for hominoids. Patterns for most clades revealed the first sutures to close are those contacting the exoccipital, interparietal, and palatine bones. Heterochronic shifts were found along 19 of 35 branches within the hystricognath phylogeny. The number of shifts per node ranged from one to seven events and, overall, involved 21 of 34 suture sites. The topology generated by parsimony analyses of the event pair matrix yielded only one grouping that was congruent with the evolutionary relationships, compiled from morphological and molecular studies, taken as framework. Sutures contacting the exoccipital displayed the highest levels of most complete closure across all species. Level of suture closure is negatively correlated with cranial length (P < 0.05). Differing life history and locomotory strategies are coupled in part with differing suture closure patterns among several species. PMID:19245501

  8. Retained strabismus suture material masquerading as nonspecific orbital inflammation.

    PubMed

    Callahan, Alison B; Scofield, Stacy M; Gallin, Pamela F; Kazim, Michael

    2016-06-01

    We report a case of orbital myositis of the superior rectus muscle-levator complex masquerading as nonspecific orbital inflammation but corresponding in location to a known braided polyester "chicken suture" placed 20 years earlier during strabismus surgery. The orbital inflammation was refractory to oral steroids but resolved promptly on surgical removal of the suture material. Although suture material is known to cause foreign body granulomatous reactions, to our knowledge this is the first reported case of a deep, diffuse orbital inflammation attributable to chicken suture placed during strabismus surgery. PMID:27112911

  9. Atypical accessory intraparietal sutures mimicking complex fractures in a neonate.

    PubMed

    Eklund, Meryle J; Carver, Keith C; Stalcup, Seth T; Riemer, Ellen C; Taylor, Michael A; Hill, Jeanne G

    2016-01-01

    Partial or complete division of the parietal bones resulting in anomalous cranial sutures is a rare entity and may raise concern for fracture and potential abuse when identified on radiological examination in young children. We present a case of a 4-week-old male found to have anomalous intraparietal sutures originally interpreted as fractures during a comprehensive evaluation for nonaccidental trauma. Our goal is to raise awareness of a complex branching pattern of accessory intraparietal sutures, which has not been previously described. Additionally, we will review the characteristics that aid in the radiologic differentiation of accessory cranial sutures and fractures. PMID:27130985

  10. Visual measurement of suture strain for robotic surgery.

    PubMed

    Martell, John; Elmer, Thomas; Gopalsami, Nachappa; Park, Young Soo

    2011-01-01

    Minimally invasive surgical procedures offer advantages of smaller incisions, decreased hospital length of stay, and rapid postoperative recovery to the patient. Surgical robots improve access and visualization intraoperatively and have expanded the indications for minimally invasive procedures. A limitation of the DaVinci surgical robot is a lack of sensory feedback to the operative surgeon. Experienced robotic surgeons use visual interpretation of tissue and suture deformation as a surrogate for tactile feedback. A difficulty encountered during robotic surgery is maintaining adequate suture tension while tying knots or following a running anastomotic suture. Displaying suture strain in real time has potential to decrease the learning curve and improve the performance and safety of robotic surgical procedures. Conventional strain measurement methods involve installation of complex sensors on the robotic instruments. This paper presents a noninvasive video processing-based method to determine strain in surgical sutures. The method accurately calculates strain in suture by processing video from the existing surgical camera, making implementation uncomplicated. The video analysis method was developed and validated using video of suture strain standards on a servohydraulic testing system. The video-based suture strain algorithm is shown capable of measuring suture strains of 0.2% with subpixel resolution and proven reliability under various conditions. PMID:21436874

  11. Cyclic loading comparison of Bio-SutureTak-#2 FiberWire and Bio Mini-Revo-#2 Hi-Fi suture anchor-sutures in cadaveric scapulae.

    PubMed

    Sparks, Brad S; Nyland, John; Nawab, Akbar; Blackburn, Ethan; Krupp, Ryan; Burden, Robert

    2008-03-01

    This study compared tap-in Bio-SutureTak suture anchor-#2 FiberWire suture (Group 1) and screw-in Bio Mini-Revo suture anchor-#2 Hi-Fi suture (Group 2) fixation in the glenoid region of interest for Bankart repair, in addition to evaluation of isolated suture loop biomechanical properties under progressive incremental cyclic loads. With knowledge of glenoid apparent bone mineral density (BMD), implant preparation and fit characteristics, and following application of a light manual tensile load, the primary investigator scored each specimen for perceived within group biomechanical test performance using a 0-10 point modified visual analog scale. After scoring, 12 paired constructs were placed in a servo hydraulic device clamp, preloaded to 25 N, and cycled between 25 and 50 Hz with a 25 N load increase every 25 cycles. Group 2 withstood greater load (104.1 +/- 56 vs. 70 +/- 36.9 N, P = 0.04) and displaced more at failure (13 +/- 4.5 vs. 8.6 +/- 3.3 mm, P = 0.04). All Group 1 specimens failed prior to reaching 150 N, whereas 25% of Group 2 specimens (n = 3) failed at 200 N. All specimens failed by anchor pullout except for three Group 2 specimens that failed by eyelet breakage at 200 N. Isolated suture testing revealed that Group 1 sutures displaced less at each cyclic load (P = 0.028) and withstood greater failure loads (P = 0.028) than that of Group 2 sutures. Group 2 constructs displayed moderately strong relationships between perceived within group biomechanical test performance and ultimate load (r (2) = 0.55) and displacement at failure (r (2) = 0.67). Group 1 did not display significant relationships. Similar biomechanical performance between 50 and 125 N, greater load at failure, and superior biomechanical test prediction accuracy suggest that the screw-in type Bio Mini-Revo suture anchor-#2 Hi-Fi suture combination may be preferred for Bankart lesion repair in low apparent BMD glenoid processes. The #2 Hi-Fi suture, however, allowed significantly greater

  12. Techniques and applications of adjustable sutures.

    PubMed

    Fells, P

    1987-02-01

    The 'rediscovery' of adjustable sutures some 10 years ago has given the ophthalmic surgeon much more confidence in his ability to correct strabismus. Three methods of use are described: during surgery under general anaesthesia with adjustment during the operation using the 'springback' test to centralise the eye; during surgery under general anaesthesia and subsequent adjustment under local anaesthesia using the patient's subjective responses to obtain optimal positioning; and performance of the operation and adjustment under topical local anaesthesia in one procedure. Full details are given of each technique and the indications for their application to particular problems are discussed. PMID:3297111

  13. A Comparison of 2-Octyl Cyanoacrylate Adhesives versus Conventional Suture Materials for Eyelid Wound Closure in Rabbits

    PubMed Central

    Shin, Dong-Min; Roh, Mee-Sook; Jeung, Woo-Jin; Park, Woo-Chan; Rho, Sae-Heun

    2011-01-01

    Purpose To evaluate the clinical efficacy and histopathological tolerance of 2-octyl cyanoacrylate versus conventional suture materials for eyelid wound closure in rabbits. Methods We performed an experimental study on 16 eyes of eight New Zealand albino rabbits. Eyelid incisions of 15 mm were done 4mm from the upper eyelid margin in both eyes. The eyes of the rabbits were divided into two groups: eyelid incisions of the right eye were closed by a 2-octyl cyanoacrylate adhesive (group A) and eyelid incisions of the left eye were closed by 7-0 nylon sutures (group B). At 1, 2, 4, and 8 weeks after surgery, the rabbits were macroscopically examined and then sacrificed. The specimens of their eyelid tissues were stained by a hematoxylin and eosin stain and Masson-trichrome stain, and were observed under microscope. Results Both eyelid surgical closure methods were found to be equally efficacious in fixing the eyelids of groups A and B, and their clinical efficacy was similar. Histopathological findings of the hematoxylin and eosin stain of group A showed less inflammatory infiltration than group B at 2 weeks. There were no significant histopathological differences between the two groups at 1, 4, and 8 weeks. The degree of fibrosis of the Masson-trichrome stain was similar between the two groups at 8 weeks. Conclusions The 2-octyl cyanoacrylate adhesive proved to be an effective eyelid closure method and was very well tolerated by the skin surface. 2-Octyl cyanoacrylate could be used as an alternative tissue adhesive for eyelid wound closure along with conventional suture materials. PMID:21461225

  14. Investigation of the Rigid Amorphous Fraction in Nylon-6

    SciTech Connect

    Chen,H.; Cebe, P.

    2007-01-01

    A three-phase model, comprising crystalline, mobile amorphous, and rigid amorphous fractions (X{sub c}, X{sub MA}, X{sub rA}, respectively) has been applied in the study of semicrystalline Nylon-6. The samples studied were Nylon-6 alpha phase prepared by subsequent annealing of a parent sample slowly cooled from the melt. The treated samples were annealed at 110 C, then briefly heated to 136 C, then re-annealed at 110 C. Temperature-modulated differential scanning calorimetry (TMDSC) measurements allow the devitrification of the rigid amorphous fraction to be examined. We observe a lower endotherm, termed the 'annealing' peak in the non-reversing heat flow after annealing at 110 C. By brief heating above this lower endotherm and immediately quenching in LN{sub 2}-cooled glass beads, the glass transition temperature and X{sub RA} decrease substantially, X{sub MA} increases, and the annealing peak disappears. The annealing peak corresponds to the point at which partial de-vitrification of the rigid amorphous fraction (RAF) occurs. Re-annealing at 110 C causes the glass transition and X{sub RA} to increase, and X{sub MA} to decrease. None of these treatments affected the measured degree of crystallinity, but it cannot be excluded that crystal reorganization or recrystallization may also occur at the annealing peak, contributing to the de-vitrification of the rigid amorphous fraction. Using a combined approach of thermal analysis with wide and small angle X-ray scattering, we analyze the location of the rigid amorphous and mobile amorphous fractions within the context of the Heterogeneous and Homogeneous Stack Models. Results show the homogeneous stack model is the correct one for Nylon-6. The cooperativity length ({var_epsilon}{sub A}) increases with a decrease of rigid amorphous fraction, or, increase of the mobile amorphous fraction. Devitrification of some of the RAF leads to the broadening of the glass transition region and shift of T{sub g}.

  15. Suture locking of isolated internal locking knotless suture anchors is not affected by bone quality

    PubMed Central

    Woodmass, Jarret M; Matthewson, Graeme; Ono, Yohei; Bois, Aaron J; Boorman, Richard S; Lo, Ian KY; Thornton, Gail M

    2015-01-01

    Purpose The purpose of this study was to evaluate the mechanical performance of different suture locking mechanisms including: i) interference fit between the anchor and the bone (eg, 4.5 mm PushLock, 5.5 mm SwiveLock), ii) internal locking mechanism within the anchor itself (eg, 5.5 mm SpeedScrew), or iii) a combination of interference fit and internal locking (eg, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S). Methods Anchors were tested in foam blocks representing normal (20/8 foam) or osteopenic (8/8 foam) bone, using standard suture loops pulled in-line with the anchor to isolate suture locking. Mechanical testing included cyclic testing for 500 cycles from 10 N to 60 N at 60 mm/min, followed by failure testing at 60 mm/min. Displacement after 500 cycles at 60 N, number of cycles at 3 mm displacement, load at 3 mm displacement, and maximum load were evaluated. Results Comparing 8/8 foam to 20/8 foam, load at 3 mm displacement and maximum load were significantly decreased (P<0.05) with decreased bone quality for anchors that, even in part, relied on an interference fit suture locking mechanism (ie, 4.5 mm PushLock, 5.5 mm SwiveLock, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S). Bone quality did not affect the mechanical performance of 5.5 mm SpeedScrew anchors which have an isolated internal locking mechanism. Conclusion The mechanical performance of anchors that relied, even in part, on interference fit were affected by bone quality. Isolated internal locking knotless suture anchors functioned independently of bone quality. Anchors with a combined type (interference fit and internal locking) suture locking mechanism demonstrated similar mechanical performance to isolated internal locking anchors in osteopenic foam comparing similar sized anchors. Clinical relevance In osteopenic bone, knotless suture anchors that have an internal locking mechanism (isolated or combined type) may be advantageous for secure tendon fixation to bone. PMID:26124683

  16. Does UV disinfection compromise sutures? An evaluation of tissue response and suture retention in salmon surgically implanted with transmitters

    SciTech Connect

    Walker, Ricardo W.; Brown, Richard S.; Deters, Katherine A.; Eppard, M. B.; Cooke, Steven J.

    2013-10-01

    Ultraviolet radiation (UVR) can be used as a tool to disinfect surgery tools used for implanting transmitters into fish. However, the use of UVR could possibly degrade monofilament suture material used to close surgical incisions. This research examined the effect of UVR on monofilament sutures to determine if they were compromised and negatively influenced tag and suture retention, incision openness, or tissue reaction. Eighty juvenile Chinook salmon Oncorhynchus tshawytscha were surgically implanted with an acoustic transmitter and a passive integrated transponder. The incision was closed with a single stitch of either a suture exposed to 20 doses of UV radiation (5 minute duration per dose) or a new, sterile suture. Fish were then held for 28 d and examined under a microscope at day 7, 14, 21 and 28 for incision openness, ulceration, redness, and the presence of water mold. There was no significant difference between treatments for incision openness, redness, ulceration or the presence of water mold on any examination day. On day 28 post-surgery, there were no lost sutures; however, 2 fish lost their transmitters (one from each treatment). The results of this study do not show any differences in negative influences such as tissue response, suture retention or tag retention between a new sterile suture and a suture disinfected with UVR.

  17. High Coverages of Hydrogen on a (10,0) Carbon Nanotube

    NASA Technical Reports Server (NTRS)

    Bauschlicher, Charles W., Jr.; Arnold, James (Technical Monitor)

    2001-01-01

    The binding energy of H to a (10,0) carbon nanotube is calculated at 24, 50, and 100% coverage. Several different bonding configurations are considered for the 50% coverage case. Using the ONIOM (our own n-layered integrated molecular orbital and molecular mechanics) approach, the average C-H bond energy for the most stable 50% coverage and for the 100% coverage are 57.3 and 38.6 kcal/mol, respectively. Considering the size of the bond energy of H2, these values suggest that it will be difficult to achieve 100% atomic H coverage on a (10,0) nanotube.

  18. Surgical device for supporting corneal suturing

    NASA Astrophysics Data System (ADS)

    Ventura, Liliane; Oliveira, Gunter C. D.; De Groote, Jean-Jacques; Sousa, Sidney J. F.; Saia, Paula

    2009-02-01

    A system for ophthalmic surgery support has been developed in order to minimize the residual astigmatism due to the induced irregular shape of the cornea by corneal suture. The system projects 36 light spots, from LEDs, displayed in a precise circle at the lachrymal film of the examined cornea. The displacement, the size and deformation of the reflected image of these light spots are analyzed providing the keratometry and the circularity of the suture. Measurements in the range of 32D - 55D (up to 23D of astigmatism are possible to be obtained) and a self-calibration system has been designed in order to keep the system calibrated. Steel precision spheres have been submitted to the system and the results show 99% of correlation with the fabricant's nominal values. The system has been tested in 13 persons in order to evaluate its clinical applicability and has been compared to a commercial keratometer Topcon OM-4. The correlation factors are 0,92 for the astigmatism and 0.99 for the associated axis. The system indicates that the surgeon should achieve circularity >=98% in order to do not induce astigmatisms over 3D.

  19. Human monocyte adherence measured by the nylon fibre microcolumn technique.

    PubMed

    Kelly, M K; Thong, Y H

    1984-11-30

    A simple rapid method for the measurement of human monocyte adherence using nylon fibre microcolumns is described. The kinetics indicate the optimal contact time to be 30 min for monocytes, compared with 10 min for neutrophils. The optimal temperature is 37 degrees C; significantly low values were obtained for 4 degrees C and 45 degrees C, while intermediate values were obtained for 25 degrees C. Monocyte adherence was more sensitive to inhibition by fluoride than cyanide, suggesting that energy for adherence is mainly derived from the glycolytic pathway. The addition of phorbol myristate acetate enhances monocyte adherence. Significant decay in monocyte adherence occurred after isolation from whole blood for 24 h or longer. PMID:6501891

  20. Electrical Properties of Conductive Nylon66/Graphene Oxide Composite Nanofibers.

    PubMed

    Nirmala, R; Navamathavan, R; Kim, Hak Yong; Park, Soo-Jin

    2015-08-01

    In this paper, we report on the structural and electrical properties of graphene oxide (GO) incorporated Nylon66 (N66) composite nanofibers prepared via electrospinning technique. Different types of composite nanofibers were electrospun by varying the weight percentage of GO in the polymer solution. Scanning electron microscopy, X-ray diffraction and Fourier transform infrared spectroscopy, as well as current-voltage (I-V) measurements were used to characterize the N66/GO composite nanofibers. The morphology of the N66/GO composite nanofibers exhibited densely arranged mesh-like ultrafine nanofibers which were strongly bound in between the main fibers. The I-V characteristics of the N66/GO composite nanofibers demonstrated that the blending of GO in to N66 nanofibers led to a dramatic improvement of the electrical conduction compared to that of pristine N66 nanofibers which can be utilized for the various technological applications. PMID:26369144

  1. An evaluation of preservative adsorption onto nylon membrane filters.

    PubMed

    Guilfoyle, D E; Roos, R; Carito, S L

    1990-01-01

    Pharmaceutical drug products often contain antimicrobial agents as a preservative in their formulation. These excipients are required to destroy or impede the growth of microorganisms that inadvertently enter the product during manufacturing. Unfortunately, these preservatives may also interfere with microbiological assays used to determine product sterility or bioburden levels. The extent of interference by these preservatives can be quite significant, but varies depending on the method used. The most frequently used method for testing parenteral drug products is the membrane filtration technique. Membrane filters are composed of a wide variety of materials such as cellulose, polycarbonate, acrylic polypropylene, Teflon, and nylon. This study evaluated the adsorption characteristics that nylon filters, obtained from five different manufacturers, had on the filtration of solutions of four different antimicrobial compounds (phenol, methylparaben, propylparaben, and benzalkonium chloride). The adsorption properties were determined using both HPLC and microbiological assay techniques. The data revealed that there was a wide range in the amounts of antimicrobial agent (2.3 to 94.1%) bound to the membrane filters when direct product filtration was used without a subsequent rinse step. However, when a rinse step is included, only propylparaben showed any significant "true" adsorption (less than 1 to 33.3%), but showed only marginal bacterial inhibition. Interestingly, the microbiological assays indicated that with a saline rinse step, only benzalkonium chloride was lethal for the two challenge organisms even though the percent adsorbed as measured by HPLC was below 1%. This discrepancy is significant because it demonstrates the analytical limitation when using HPLC to detect minimal concentrations of benzalkonium chloride that may be deleterious to microorganisms.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:2277319

  2. Tuning the mechanical properties of SWNT/nylon 6,10 composites with flexible spacers at the interface.

    PubMed

    Moniruzzaman, Mohammad; Chattopadhyay, Jayanta; Billups, W Edward; Winey, Karen I

    2007-05-01

    We have prepared nylon 6,10 nanocomposites using functionalized single wall carbon nanotubes and our interfacial in situ polycondensation method. The specific functional groups -(CH2)nCOCl [n = 4 and 9] on the sidewalls of SWNT were designed to covalently link nanotubes to the nylon matrix via alkyl segments. The composites with functionalized SWNT show significant improvements in tensile modulus, strength, and toughness relative to nylon and nylon modified with non-functionalized SWNT. The alkyl linkages at the SWNT/nylon 6,10 interface contribute significantly to improving the toughness of the composites. PMID:17397230

  3. Physio-chemical and antibacterial characteristics of pressure spun nylon nanofibres embedded with functional silver nanoparticles.

    PubMed

    Xu, Z; Mahalingam, S; Rohn, J L; Ren, G; Edirisinghe, M

    2015-11-01

    A novel and facile approach to prepare hybrid nanoparticle embedded polymer nanofibers using pressurised gyration is presented. Silver nanoparticles and nylon polymer were used in this work. The polymer solution's physical properties, rotating speed and the working pressure had a significant influence on the fibre diameter and the morphology. Fibres in the range of 60-500nm were spun using 10wt.%, 15wt.% and 20wt.% nylon solutions and these bead-free fibres were processed under 0.2MPa and 0.3MPa working pressure and a rotational speed of 36,000rpm. 1-4wt.% of Ag was added to these nylon solutions and in the case of wt.% fibres in the range 50-150nm were prepared using the same conditions of pressurised gyration. Successful incorporation of the Ag nanoparticles in nylon nanofibres was confirmed by using a combination of advanced microscopical techniques and Raman spectrometry was used to study the bonding characteristics of nylon and the Ag nanoparticles. Inductively coupled plasma mass spectroscopy showed a substantial concentration of Ag ions in the nylon fibre matrix which is essential for producing effective antibacterial properties. Antibacterial activity of the Ag-loaded nanofibres shows higher efficacy than nylon nanofibres for Gram-negative Escherichia coli and Pseudomonas aeruginosa microorganisms, and both Ag nanoparticles and the Ag ions were found to be the reason for enhanced cell death in the bacterial solutions. PMID:26249581

  4. Suture Bridge Fixation Technique for Posterior Cruciate Ligament Avulsion Fracture

    PubMed Central

    Lee, Kwang Won; Lee, Gyu Sang; Choy, Won Sik

    2015-01-01

    We presented a surgical technique including a suture bridge technique with relatively small incision for the reduction and fixation of posterior ligament avulsion fractures. A suture anchor was used to hold the avulsed fragment and a knotless anchor was used to continuously compress the bony fragment into the fracture site, thereby maintaining reduction during healing. PMID:26640635

  5. Interdomal Suture through a Nondelivery Endonasal Approach: A New Technique

    PubMed Central

    Leibou, Lior

    2016-01-01

    Background: The use of interdomal sutures for tip refinement is common in open rhinoplasty and in endonasal rhinoplasty using a delivery technique, but there is paucity of reports in the literature regarding the use of interdomal suturing techniques when the nondelivery endonasal approach is chosen. Objective: The authors describe a technique designed to refine the nasal tip with an interdomal suture placed through a nondelivery endonasal approach. Methods: In this study, the authors retrospectively review the cases of 45 patients who underwent endonasal rhinoplasty with the authors’ interdomal suturing technique between the years 2011 and 2013. The average age of the patients was 25.3 years. Intercrural sutures (PDS 4.0 straight needle, Cincinnati, Ohio) were placed as mattress-like suture in the tip region, with the knot buried between both alar cartilages. The suture is tightened progressively according to the tip definition and narrowing sought. Results: The patients were followed for 12 months. All of the patients demonstrated a significant reduction in lobule and tip widths. This series had only 1 complication of tip asymmetry that was revised 1 year after the initial operation. There were no cases of infection, allergic reaction, or extrusion of the suture. Conclusions: Despite the lack of a large volume of patients, our study confirms that this technique is indeed an attractive and highly predictable option for achieving adequate tip refinement and definition when using a nondelivery endonasal rhinoplasty. PMID:27622086

  6. 21 CFR 878.4830 - Absorbable surgical gut suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Absorbable surgical gut suture. 878.4830 Section 878.4830 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4830 Absorbable surgical gut suture. (a) Identification. An...

  7. Structural grafts and suture techniques in functional and aesthetic rhinoplasty

    PubMed Central

    Gassner, Holger G.

    2011-01-01

    Rhinoplasty has undergone important changes. With the advent of the open structure approach, requirements for structural grafting and direct manipulation of the cartilaginous skeleton through suture techniques have increased substantially. The present review analyzes the current literature on frequently referenced structural grafts and suture techniques. Individual techniques are described and their utility is discussed in light of available studies and data. PMID:22073105

  8. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  9. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  10. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  11. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  12. 21 CFR 878.4930 - Suture retention device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Suture retention device. 878.4930 Section 878.4930 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices § 878.4930 Suture retention...

  13. A rabbit model of human familial, nonsyndromic unicoronal suture synostosis. I. Synostotic onset, pathology, and sutural growth patterns.

    PubMed

    Mooney, M P; Siegel, M I; Burrows, A M; Smith, T D; Losken, H W; Dechant, J; Cooper, G; Kapucu, M R

    1998-06-01

    Poswillo has stated, "The more severe anomalies of the calvaria, such as plagiocephaly, Crouzon [syndrome], and Apert syndrome still defy explanation, in the absence of an appropriate animal system to study" (p. 207). This two-part study reviews data from a recently developed colony of New Zealand white rabbits with familial, nonsyndromic unilateral coronal suture synostosis. Part 1 presents pathological findings and compensatory sutural growth data from 109 normal rabbits and 82 craniosynostotic rabbits from this colony. Synostotic foci, onset, and progression were described in the calvariae from 102 staged (fetal days 21, 25, 27, 33; term = 30 days) fetuses (39 normal, 63 synostosed). Calvarial suture growth patterns from 10 to 126 days of age were assessed from serial radiographs obtained from 89 rabbits (70 normal rabbits and 19 rabbits with unicoronal suture synostosis) with amalgam bone marker implants. Perinatal results revealed that by fetal day 25 the synostotic focal point in synostotic rabbits consistently originated from the endocortical surface of the calvaria in the middle of the coronal suture at a presumed high-tension, interdigitating zone. Histological analysis revealed hyperostotic osteogenic fronts on the affected side compared with the unaffected side. Postnatal sutural growth data revealed a predictable pattern of plagiocephaly (contralateral coronal sutures growing more than ipsilateral sutures and ipsilateral frontonasal and anterior lambdoidal sutures growing more than contralateral sutures), which resulted in early cranial vault deformities and a double "S" shape torquing towards the affected side. The advantages and disadvantages of these rabbits as a model for human familial, nonsyndromic unicoronal suture synostosis are discussed, especially in light of recent cytokine and genetic findings from human craniosynostotic studies. PMID:9694335

  14. Surface modifications of nylon/carbon fiber composite for improving joint adhesion

    SciTech Connect

    Wu, R.; Liao, S.L.; Tong, T.S.; Young, J.T.

    1996-12-31

    Various methods were used to modify the nylon/carbon fiber composite surfaces, including grit blasting, flame and plasma pretreatments. The surfaces of nylon composites after pretreatments were characterized by contact angle measurements, scanning electron microscopy (SEM), and X-ray photoelectron spectroscopy (XPS). XPS results show that several functional groups were formed after plasma and flame pretreatments. The scanning electron microscope (SEM) photographs suggest that the blasting pretreatment increased the surface roughness of nylon composites. All these surface pretreatments dramatically increased the lap shear strength if proper operation conditions were used. The reasons for the increase of lap shear strength were explained.

  15. Automatic Initialization and Dynamic Tracking of Surgical Suture Threads

    PubMed Central

    Jackson, Russell C.; Yuan, Rick; Chow, Der-Lin; Newman, Wyatt; Çavuşoğlu, M. Cenk

    2015-01-01

    In order to realize many of the potential benefits associated with robotically assisted minimally invasive surgery, the robot must be more than a remote controlled device. Currently using a surgical robot can be challenging, fatiguing, and time consuming. Teaching the robot to actively assist surgical tasks, such as suturing, has the potential to vastly improve both patient outlook and the surgeon’s efficiency. One obstacle to completing surgical sutures autonomously is the difficulty in tracking surgical suture threads. This paper proposes an algorithm which uses a Non-Uniform Rational B-Spline (NURBS) curve to model a suture thread. The NURBS model is initialized from a single selected point located on the thread. The NURBS curve is optimized by minimizing the image match energy between the projected stereo NURBS image and the segmented thread image. The algorithm is able to accurately track a suture thread as it translates, deforms, and changes length in real-time. PMID:26413383

  16. Prospective, noncomparative, nonrandomized case study of short-term outcomes of 360° suture trabeculotomy ab interno in patients with open-angle glaucoma

    PubMed Central

    Sato, Tomoki; Hirata, Akira; Mizoguchi, Takanori

    2015-01-01

    Background In this paper, we describe 360° suture trabeculotomy (360°LOT) ab interno and the short-term course in patients who underwent this procedure. Methods We prospectively studied 12 patients (12 eyes) with open-angle glaucoma who underwent 360°LOT ab interno at the Sato Eye Clinic between February and July 2014. The surgical procedure involved making a 1.7 mm temporal corneal incision, exposing an approximately 15° opening in the inner wall of Schlemm’s canal (nasal side) using a Trabectome with a gonioscope, and inserting a 5-0 nylon suture rounded at the tip into Schlemm’s canal opened via the anterior chamber. The suture was then threaded around Schlemm’s canal, and the tip of the suture that emerged on the other side was then advanced through the opening to make a circumferential incision. Intraocular pressure (IOP), number of anti-glaucoma medications used, complications, and the surgery completion rate were prospectively studied. Results Mean IOP, which was 19.4 mmHg at baseline, showed a significant decrease at each of the monthly observation points, reaching 13.8 mmHg at 6 months after surgery (P=0.0004, paired t-test). The mean number of anti-glaucoma medications decreased from 3.2 at baseline to 1.1 at 6 months after surgery. IOP spikes ≥30 mmHg were seen in 25% of patients, but there were no other serious complications and the surgery completion rate was 92%. Conclusion The 360°LOT ab interno procedure preserves the conjunctiva and sclera, and has a high surgery completion rate when using the anterior chamber approach, and could therefore be an effective short-term treatment of open-angle glaucoma. PMID:25609906

  17. Nylon 6 water-permeable membranes prepared by electron beam radiation-induced graft copolymerization

    SciTech Connect

    Harugy, Y.; Rajbenbach, A.L.

    1981-09-01

    Nylon 6 films, 25 ..mu..m thick, were grafted with polar monomers in aqueous solution following preirradiation with a 550-kV electron beam accelerator. The graft yield rose linearly with grafting period up to 100% graft and leveled off at a graft yield above 150%. At 100 to 200% graft of several acrylic acid derivatives onto the nylon 6 films, water permeation rates comparable to those of PVA and cellophane films were observed. These high water permeation rates of the grafted nylon films were considered as an indication that some of the acrylate copolymers penetrated throughout the matrix of the host polymer. The highest rates of water permeability were observed in nylon acrylamide grafts.

  18. Measurement of the radon diffusion through a nylon foil for different air humidities

    SciTech Connect

    Mamedov, Fadahat; Štekl, Ivan; Smolek, Karel

    2015-08-17

    The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained results of this study with a nylon foil with the thickness of 50 µm are presented.

  19. Measurement of the radon diffusion through a nylon foil for different air humidities

    NASA Astrophysics Data System (ADS)

    Mamedov, Fadahat; Štekl, Ivan; Smolek, Karel

    2015-08-01

    The dependency of the radon penetration through a nylon foil on air humidity was measured. Such information is needed for the tracking part of the SuperNEMO detector, which is planned to be shielded against radon by nylon foil and in which the air humidity is not negligible. The long term measurements of radon penetration through nylon foils for different air humidities were performed with the radon diffusion setup constructed at the IEAP, CTU in Prague. The setup consists of two stainless steel hemispheres with Si detector in each of them. Both hemispheres are separated by the tested foil. While the left hemisphere contains high Rn activity, the right part contains only activity caused by the radon penetration through the tested foil. Obtained results of this study with a nylon foil with the thickness of 50 µm are presented.

  20. Influence of electrostatic charge on the performance of 10 mm nylon cyclones

    SciTech Connect

    Briant, J.K.; Moss, O.R.

    1984-07-01

    The 10 mm nylon cyclone is commonly used for measuring the respirable aerosol concentration of airborne dust. Under some conditions the measured concentration may be lower than the actual value due to electrostatic charge. The use of a cyclone moulded from conducting, graphite-filled nylon is proposed. Tests of such a cyclone are reported. The results showed a consistency, providing a more accurate representation of deposition in the human respiratory tract.

  1. Permeability of noble gases through Kapton, butyl, nylon, and “Silver Shield”

    NASA Astrophysics Data System (ADS)

    Schowalter, Steven J.; Connolly, Colin B.; Doyle, John M.

    2010-04-01

    Noble gas permeabilities and diffusivities of Kapton, butyl, nylon, and "Silver Shield" are measured at temperatures between 22 and 115C. The breakthrough times and solubilities at 22C are also determined. The relationship of the room temperature permeabilities to the noble gas atomic radii is used to estimate radon permeability for each material studied. For the noble gases tested, Kapton and Silver Shield have the lowest permeabilities and diffusivities, followed by nylon and butyl, respectively.

  2. Granuloma formation secondary to Achilles tendon repair with nonabsorbable suture

    PubMed Central

    Kara, Adnan; Celik, Haluk; Seker, Ali; Uysal, Mehmet Ali; Uzun, Metin; Malkoc, Melih

    2014-01-01

    INTRODUCTION Several complications can be observed after Achilles tendon repairs. In this study we aimed to report granuloma formation secondary to Achilles tendon repair with Ethibond (Ethicon INC, Somerville, New Jersey) suture. PRESENTATION OF CASE A 31 year-old man operated for Achilles tendon rupture. The Ethibond suture was used for primary repair. The patient attended to polyclinic with the complaints of swelling and discharge around the operation site four months after operation. A mass around distal portion of the Achilles tendon was detected. The granulomatous tissue was excised. Inside the mass Ethibond suture was detected. On histopathologic examination, typical findings of the foreign body reaction were observed. No microorganism was cultivated in the tissue culture. The patient has no complaint on the twelfth month control after surgery. DISCUSSION The results of primary repair of Achilles tendon are good but several complications were reported. In tendon repairs generally nonabsorbable sutures are used. The Ethibond is nonabsorbable, braided suture. In the literature, granuloma formations secondary to the suture materials such as polygylactine and braided polyethylen–polyester after Achilles tendon repair were reported but granuloma secondary to the Ethibond is very rare. CONCLUSION Although Ethibond suture is a strong and safe material for Achilles tendon repairs it may cause soft tissue problems such as granuloma. PMID:25212905

  3. A comparison of ultrasonic suture welding and traditional knot tying.

    PubMed

    Richmond, J C

    2001-01-01

    The slippage of knots and the technical challenge of tying them securely are potential impediments to certain arthroscopic procedures. Ultrasonic energy delivered at 70 kHz can be used to weld No. 2 polypropylene suture. This method was compared with a traditional knot (surgeon's knot with four alternating half hitches) tied with an open technique to determine whether welding of sutures is comparable, in mechanical properties, to hand-tied knots. Both loops were fashioned around a 0.25-inch mandrel and then tested. The load to reach 3-mm elongation (point of likely biologic failure of a repair) was significantly greater for welded sutures than for knots. The elongation at ultimate failure was significantly less for welded sutures than for knots. The number of cycles to failure and the creep after initial displacement were similar for both welded and knotted suture loops. The ultimate load to failure was significantly greater for the knotted than for the welded suture. The welding of suture for the repair of musculoskeletal soft tissue presents an attractive alternative to traditional knot tying, particularly for arthroscopic applications. PMID:11394598

  4. Alignment of carbon nanotubes and reinforcing effects in nylon-6 polymer composite fibers.

    PubMed

    Rangari, Vijaya K; Yousuf, Mohammed; Jeelani, Shaik; Pulikkathara, Merlyn X; Khabashesku, Valery N

    2008-06-18

    Alignment of pristine carbon nanotubes (P-CNTs) and fluorinated carbon nanotubes (F-CNTs) in nylon-6 polymer composite fibers (PCFs) has been achieved using a single-screw extrusion method. CNTs have been used as filler reinforcements to enhance the mechanical and thermal properties of nylon-6 composite fibers. The composites were fabricated by dry mixing nylon-6 polymer powder with the CNTs as the first step, then followed by the melt extrusion process of fiber materials in a single-screw extruder. The extruded fibers were stretched to their maxima and stabilized using a godet set-up. Finally, fibers were wound on a Wayne filament winder machine and tested for their tensile and thermal properties. The tests have shown a remarkable change in mechanical and thermal properties of nylon-6 polymer fibers with the addition of 0.5 wt% F-CNTs and 1.0 wt% of P-CNTs. To draw a comparison between the improvements achieved, the same process has been repeated with neat nylon-6 polymer. As a result, tensile strength has been increased by 230% for PCFs made with 0.5% F-CNTs and 1% P-CNTs as additives. These fibers have been further characterized by DSC, Raman spectroscopy and SEM which confirm the alignment of CNTs and interfacial bonding to nylon-6 polymer matrix. PMID:21825828

  5. [Research on structure of MC-nylon 6/aramid composites by spectroanalysis method].

    PubMed

    Wang, Can-Yao; Zheng, Yu-Ying

    2008-01-01

    The Kevlar fiber, treated with toluene-2,4-diisocyanate and caprolactam, was used to reinforce MC nylon 6. XPS showed the change in chemical components and spectra after fiber was treated. IR showed that the spectra of Kevlar fiber and MC-nylon 6 were incorporated purely when they were mixed, while the treated Kevlar fiber provided the activation in the ring-opening polymerization of caprolactam, and the amide groups of graft chains could form strong hydrogen bonds with matrix. These graft chains and hydrogen bonds would contribute to improving interfacial bonding between MC-nylon 6 and Kevlar fiber. XRD indicated that the induction of Kevlar fiber had no effect on the cryastalline style of MC-nylon 6 obviously, however, the crystals had better seasonal structure. The crystals of MC-nylon 6/Kevlar fiber composites were more perfect than that of MC-nylon 6/Kevlar untreated fiber composites with the same amount of Kevlar fiber. The increase of Kevlar fiber contributed to forming perfect a spherulite when the mass concentration of Kevlar fiber was less than 2%, however, the more the Kevlar fiber, the less the content of a spherulite when the mass concentration of Kevlar fiber was more than 2%. PMID:18422127

  6. Ferroeletricity and Double Hysteresis Loop Behavior in Even-Numbered n-Nylons

    NASA Astrophysics Data System (ADS)

    Zhang, Zhongbo; Zhu, Lei; Litt, Morton

    2015-03-01

    Ferroelectric (FE) property in odd-numbered n-nylons has been known for a long time. In comparison, even-numbered n-nylons are claimed to be non-ferroelectric due to their non-polar crystalline structure, where the direction of hydrogen bonded dipoles alternates. Nevertheless, in this presentation, FE property is discovered in even n-nylons, and it is related to the mesomorphic crystalline structure formed via quenching and/or stretching. Although there was an earlier claim maintaining that FE behavior in melt-quenched nylon 6 was due to the amorphous phase, the conclusion is debatable and the understanding of the FE mechanism is still lacking. We find that poorly bonded amide dipoles, which result from the defective crystalline mesophase, play an important role in the FE behavior of nylon 12. In this mesophase, the chain conformation is smectic-like, twisted, and the hydrogen bonds are randomized. Therefore, this mesophase is abundant in defects and poorly bonded dipoles, which can easily flip under electric field. In addition, the hydrogen-bonded amides can serve as pinning points and induce double hysteresis loop behavior. This understanding illustrates that FE in even n-nylons originates from the defective crystalline phase rather than the amorphous region. NSF (DMR0907580).

  7. Templated synthesis of nylon nucleic acids and characterization by nuclease digestion

    PubMed Central

    Liu, Yu; Wang, Risheng; Ding, Liang; Sha, Roujie

    2012-01-01

    Nylon nucleic acids containing oligouridine nucleotides with pendent polyamide linkers and flanked by unmodified heteronucleotide sequences were prepared by DNA templated synthesis. Templation was more efficient than the single-stranded synthesis: Coupling step yields were as high as 99.2%, with up to 7 amide linkages formed in the synthesis of a molecule containing 8 modified nucleotides. Controlled digestion by calf spleen phosphodiesterase enabled the mapping of modified nucleotides in the sequences. A combination of complete degradation of nylon nucleic acids by snake venom phosphodiesterase and dephosphorylation of the resulting nucleotide fragments by bacterial alkaline phosphatase, followed by LCMS analysis, clarified the linear structure of the oligo-amide linkages. The templated synthesis strategy afforded nylon nucleic acids in the target structure and was compatible with the presence heteronucleotides. The complete digestion procedure produced a new species of DNA analogues, nylon ribonucleosides, which display nucleosides attached via a 2′-alkylthio linkage to each diamine and dicarboxylate repeat unit of the original nylon nucleic acids. The binding affinity of a nylon ribonucleoside octamer to the complementary DNA was evaluated by thermal denaturing experiments. The octamer was found to form stable duplexes with an inverse dependence on salt concentration, in contrast to the salt-dependent DNA control. PMID:23125913

  8. Nylon 6,6 Nonwoven Fabric Separates Oil Contaminates from Oil-in-Water Emulsions

    PubMed Central

    Carter, Erin S.; Ortega, Albert E.

    2016-01-01

    Industrial oil spills into aquatic environments can have catastrophic environmental effects. First responders to oil spills along the coast of the Gulf of Mexico in the southern United States have used spunbond nylon fabric bags and fences to separate spilled oil and oil waste from contaminated water. Low area mass density spunbond nylon is capable of sorbing more than 16 times its mass in low viscosity crude oil and more than 26 times its mass in higher viscosity gear lube oil. Nylon bags separated more than 95% of gear lube oil contaminate from a 4.5% oil-in-water emulsion. Field testing of spunbond nylon fences by oil spill first responders has demonstrated the ability of this material to contain the oily contaminate while allowing water to flow through. We hypothesize that the effectiveness of nylon as an oil filter is due to the fact that it is both more oleophilic and more hydrophilic than other commonly used oil separation materials. The nylon traps oil droplets within the fabric or on the surface, while water droplets are free to flow through the fabric to the water on the opposite side of the fabric. PMID:27411088

  9. Nylon 6,6 Nonwoven Fabric Separates Oil Contaminates from Oil-in-Water Emulsions.

    PubMed

    Ortega, Ryan A; Carter, Erin S; Ortega, Albert E

    2016-01-01

    Industrial oil spills into aquatic environments can have catastrophic environmental effects. First responders to oil spills along the coast of the Gulf of Mexico in the southern United States have used spunbond nylon fabric bags and fences to separate spilled oil and oil waste from contaminated water. Low area mass density spunbond nylon is capable of sorbing more than 16 times its mass in low viscosity crude oil and more than 26 times its mass in higher viscosity gear lube oil. Nylon bags separated more than 95% of gear lube oil contaminate from a 4.5% oil-in-water emulsion. Field testing of spunbond nylon fences by oil spill first responders has demonstrated the ability of this material to contain the oily contaminate while allowing water to flow through. We hypothesize that the effectiveness of nylon as an oil filter is due to the fact that it is both more oleophilic and more hydrophilic than other commonly used oil separation materials. The nylon traps oil droplets within the fabric or on the surface, while water droplets are free to flow through the fabric to the water on the opposite side of the fabric. PMID:27411088

  10. Polyvinyl alcohol {gamma}-ray grafted nylon 4 membrane for pervaporation and evapomeation

    SciTech Connect

    Lai, J.Y.; Chen, R.Y.; Lee, K.R

    1993-05-01

    Nylon 4, which possesses high mechanical strength and good affinity for water, can be considered as a liquid separation membrane. To improve the hydrophilicity of a Nylon 4 membrane for pervaporation and evapomeation processes, and to overcome the hydrolysis of polyvinyl alcohol (PVA), this study attempts to prepare a PVA-g-Nylon 4 membrane by {gamma}-ray irradiation grafting of vinyl acetate (VAc) onto Nylon 4 membrane, followed by hydrolysis treatment. The effects of down-stream pressure, irradiation dose, VAc monomer concentration, degree of grafting, feed composition, and size of alcohols on the separation of water-alcohol mixtures were studied. The surface properties of the prepared membrane were characterized by FTIR, ESCA, and a contact angle meter. A separation factor of 13.8 and a permeation rate of 0.352 kg/m{sup 2}-h can be obtained for a PVA-g-Nylon 4 membrane with a degree of grafting of 21.2% for a 90-wt% ethanol feed concentration. Compared to the pervaporation process, the evapomeation process has a significantly increased separation factor with a decreased permeation rate for the same PVA-g-Nylon 4 membrane. 24 refs., 9 figs., 4 tabs.

  11. Effects of BMP-12-Releasing Sutures on Achilles Tendon Healing

    PubMed Central

    Chamberlain, Connie S.; Lee, Jae-Sung; Leiferman, Ellen M.; Maassen, Nicholas X.; Baer, Geoffrey S.

    2015-01-01

    Tendon healing is a complex coordinated event orchestrated by numerous biologically active proteins. Unfortunately, tendons have limited regenerative potential and as a result, repair may be protracted months to years. Current treatment strategies do not offer localized delivery of biologically active proteins, which may result in reduced therapeutic efficacy. Surgical sutures coated with nanostructured minerals may provide a potentially universal tool to efficiently incorporate and deliver biologically active proteins directly to the wound. Additionally, previous reports indicated that treatment with bone morphogenetic protein-12 (BMP-12) improved tendon healing. Based on this information, we hypothesized that mineral-coated surgical sutures may be an effective platform for localized BMP-12 delivery to an injured tendon. The objective of this study was, therefore, to elucidate the healing effects of mineral-coated sutures releasing BMP-12 using a rat Achilles healing model. The effects of BMP-12-releasing sutures were also compared with standard BMP-12 delivery methods, including delivery of BMP-12 through collagen sponge or direct injection. Rat Achilles tendons were unilaterally transected and repaired using BMP-12-releasing suture (0, 0.15, 1.5, or 3.0 μg), collagen sponge (0 or 1.5 μg BMP-12), or direct injection (0 or 1.5 μg). By 14 days postinjury, repair with BMP-12-releasing sutures reduced the appearance of adhesions to the tendon and decreased total cell numbers. BMP-12 released from sutures and collagen sponge also tended to improve collagen organization when compared with BMP-12 delivered through injection. Based on these results, the release of a protein from sutures was able to elicit a biological response. Furthermore, BMP-12-releasing sutures modulated tendon healing, and the delivery method dictated the response of the healing tissue to BMP-12. PMID:25354567

  12. Antimicrobial effect of nylon fiber immersed with nano-silver

    NASA Astrophysics Data System (ADS)

    Haryono, Agus; Harmami, Sri Budi; Sondari, Dewi

    2010-05-01

    The development of new products based on the immobilization of nanoparticles on fibers has recently received a growing interest from both the academic and industrial sectors. A wide range of nanoparticles and nano-structures can be immobilized on fibers, which brings new properties to the final product. In the present work, silver nanoparticle was immobilized on nylon fibers by immersed deposition method as an antimicrobial agent. Silver colloid was produced by chemical reduction of silver salt (silver nitrate) solution, in the presence of sodium citrate. Synthesis of silver colloid was carried out by using chemical reduction method at temperature of 95 and 100°C. The mixture was heated until color changed into pale yellow. UV-Vis spectrometry indicated formation of silver nanoparticles. UV-Vis analysis was reported that the absorption spectrum of silver nanoparticles showed a maximum between 420 and 450 nm. Characterization of silver nanoparticles was conducted using Fourier Transformed Infra Red (FTIR) spectroscopy, UV-Vis spectroscopy, particle size analyzer (PSA), and scanning electron microscope (SEM). It was found that silver nanoparticles forms aggregates on the surface of fiber, during deposition process. The size of aggregates varied from 19.9 +/- 4.8 nm to 49.5 +/- 12.5 nm. To evaluate the antimicrobial effects against microorganisms, we used representative microorganisms S. aureus. Silver nanoparticles showed antimicrobial activity reducing bacterial growth.

  13. Highly Stretchable Non-volatile Nylon Thread Memory

    PubMed Central

    Kang, Ting-Kuo

    2016-01-01

    Integration of electronic elements into textiles, to afford e-textiles, can provide an ideal platform for the development of lightweight, thin, flexible, and stretchable e-textiles. This approach will enable us to meet the demands of the rapidly growing market of wearable-electronics on arbitrary non-conventional substrates. However the actual integration of the e-textiles that undergo mechanical deformations during both assembly and daily wear or satisfy the requirements of the low-end applications, remains a challenge. Resistive memory elements can also be fabricated onto a nylon thread (NT) for e-textile applications. In this study, a simple dip-and-dry process using graphene-PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) ink is proposed for the fabrication of a highly stretchable non-volatile NT memory. The NT memory appears to have typical write-once-read-many-times characteristics. The results show that an ON/OFF ratio of approximately 103 is maintained for a retention time of 106 s. Furthermore, a highly stretchable strain and a long-term digital-storage capability of the ON-OFF-ON states are demonstrated in the NT memory. The actual integration of the knitted NT memories into textiles will enable new design possibilities for low-cost and large-area e-textile memory applications. PMID:27072786

  14. Highly Stretchable Non-volatile Nylon Thread Memory

    NASA Astrophysics Data System (ADS)

    Kang, Ting-Kuo

    2016-04-01

    Integration of electronic elements into textiles, to afford e-textiles, can provide an ideal platform for the development of lightweight, thin, flexible, and stretchable e-textiles. This approach will enable us to meet the demands of the rapidly growing market of wearable-electronics on arbitrary non-conventional substrates. However the actual integration of the e-textiles that undergo mechanical deformations during both assembly and daily wear or satisfy the requirements of the low-end applications, remains a challenge. Resistive memory elements can also be fabricated onto a nylon thread (NT) for e-textile applications. In this study, a simple dip-and-dry process using graphene-PEDOT:PSS (poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) ink is proposed for the fabrication of a highly stretchable non-volatile NT memory. The NT memory appears to have typical write-once-read-many-times characteristics. The results show that an ON/OFF ratio of approximately 103 is maintained for a retention time of 106 s. Furthermore, a highly stretchable strain and a long-term digital-storage capability of the ON-OFF-ON states are demonstrated in the NT memory. The actual integration of the knitted NT memories into textiles will enable new design possibilities for low-cost and large-area e-textile memory applications.

  15. Summary of aging effects on 25-year old nylon parachutes

    SciTech Connect

    Tadios, E.L.

    1989-01-01

    The results of structural evaluations on several parachute systems were examined to determine if any trends could be found that would indicate significant aging in the materials. All of the parachutes were more than 20 years old. Five 64 ft diameter parachutes were evaluated along with three 16.5 ft diameter ribbon parachutes and one 4 ft diameter guide surface parachute. Another group included six 48 ft diameter ribbon parachutes, two 4 ft diameter guide surface parachutes, and two 16.5 ft diameter extraction ribbon parachutes. The parachute systems used in the study were all fabricated from nylon materials. Data were obtained for several material properties such as tensile strength, air permeability and melting point. Military specifications were used as zero-time data base due to lack of raw material data. Generally speaking, after 25 years the material properties of the 64 ft parachutes were within specifications. The same generalization cannot be made for the 48 ft parachutes which were about 23 years old. The explanation for their differences may lie in their respective histories. 10 refs., 2 figs., 5 tabs.

  16. A multiphase transitioning peptide hydrogel for suturing ultrasmall vessels.

    PubMed

    Smith, Daniel J; Brat, Gabriel A; Medina, Scott H; Tong, Dedi; Huang, Yong; Grahammer, Johanna; Furtmüller, Georg J; Oh, Byoung Chol; Nagy-Smith, Katelyn J; Walczak, Piotr; Brandacher, Gerald; Schneider, Joel P

    2016-01-01

    Many surgeries are complicated by the need to anastomose, or reconnect, micrometre-scale vessels. Although suturing remains the gold standard for anastomosing vessels, it is difficult to place sutures correctly through collapsed lumen, making the procedure prone to failure. Here, we report a multiphase transitioning peptide hydrogel that can be injected into the lumen of vessels to facilitate suturing. The peptide, which contains a photocaged glutamic acid, forms a solid-like gel in a syringe and can be shear-thin delivered to the lumen of collapsed vessels (where it distends the vessel) and the space between two vessels (where it is used to approximate the vessel ends). Suturing is performed directly through the gel. Light is used to initiate the final gel-sol phase transition that disrupts the hydrogel network, allowing the gel to be removed and blood flow to resume. This gel adds a new tool to the armamentarium for micro- and supermicrosurgical procedures. PMID:26524396

  17. Ab initio study of semiconductor atoms impurities in zigzag edge (10,0) carbon nanotubes

    SciTech Connect

    Muttaqien, Fahdzi Suprijadi

    2015-04-16

    The substitutional impurities in zigzag edge (10,0) carbon nanotubes have been studied by using first principles calculations. Silicon (Si), gallium (Ga), and arsenic (As) atom have been chosen as semiconductor based-atom for replacing carbon atoms in CNT’s surface. The silicon atom changes the energy gap of pristine zigzag (10,0) CNT, it is 0.19 eV more narrow than that of pristine CNT. Geometrically, the silicon atom creates sp{sup 3} bond with three adjacent carbon atoms, where the tetrahedral form of its sp{sup 3} bond is consisted of free unoccupied state. The silicon atom does not induce magnetism to zigzag CNT. Due to gallium (Ga) and arsenic (As) atom substitution, the zigzag CNT becomes metallic and has magnetic moment of 1 µ{sub B}. The valance and conduction band are crossed each other, then the energy gap is vanished. The electronic properties of GaAs-doped CNT are dominantly affected by gallium atom and its magnetic properties are dominantly affected by arsenic atom. These results prove that the CNT with desired properties can be obtained with substitutional impurities without any giving structural defect.

  18. Suture materials: composition and applications in veternary wound repair.

    PubMed

    Tan, R H H; Bell, R J W; Dowling, B A; Dart, A J

    2003-03-01

    Suture materials play an important role in veterinary surgery by providing support for healing tissues during wound repair. As there is no single ideal suture material, clinicians must compromise on some properties when selecting a material for a specific purpose. By reviewing the characteristics of absorbable and non-absorbable materials, general recommendations can be made on their usage in skin, fascia, viscera and other tissues. PMID:15080426

  19. [Skull fracture or accessory suture in a child?].

    PubMed

    Burkhard, Katrin; Lange, Lena M; Plenzig, Stefanie; Verhoff, Marcel A; Kölzer, Sarah C

    2016-01-01

    Differentiation between accessory sutures and fractures in the skull of an infant can be difficult. Apart from the regular sutures there is a multitude of variations that may be mistaken for a fracture line. Such variations include for instance the intraparietal suture between the two ossification centers of the parietal bone or the mendosal suture between the supraoccipital and interparietal bone of the occipital squama. The presented case refers to an approximately 20-month-old female child. During autopsy, a discontinuity in the right paramedian posterior cranial fossa parallel to the internal occipital crest with connection to the foramen magnum was observed. The macroscopic findings suggested a fracture line because of its course. However, neither a hemorrhage in the soft tissue nor callus formation was discernible. The discontinuity was preserved with the adjacent parts of the occipital bone for further histological examination. In the report of a cranial CT, which was carried out five days before the child's death, an accessory suture paramedially in the right posterior cranial fossa was described. When the clinical CT records were re-evaluated, a similar discontinuity at the corresponding position on the other side was detected, though of noticeably shorter length. Additionally, the preserved occipital bone fragment including the discontinuity was histologically processed. In the radiological literature, precise (radiological) criteria for differential diagnosis are indicated. A zigzag pattern with sclerotic borders and a bilateral and fairly symmetric occurrence indicate a suture, whereas a sharp lucency with non-sclerotic edges and a unilateral occurrence indicate a fracture. Taking all the findings into account, the depicted discontinuity was regarded as an accessory suture. This case demonstrates that differentiation between a fracture and an accessory suture may be difficult in the autopsy of a child and underlines the importance of a postmortem CT

  20. Experimental evaluation of horse hair as a nonabsorbable monofilament suture

    PubMed Central

    Yedke, Swati R.; Raut, Subhash Y.; Jangde, C. R.

    2013-01-01

    Background: Success of surgery depends on wound closure and healing. Ancients had coated many suture materials from plant and animal origin. As the quest for natural nonabsorbable, monofilament surgical suture continues, horsehair has been taken for study, which is mentioned in ancient literature. Objectives: Aim of the study was to evaluate detail mechanical and biophysical properties of horsehair. Materials and Methods: Physical properties, that are diameter, straight pull and knot pull tensile strength, bioburden, sterility tests were performed. Visual and histological wound healing parameters were studied in experimental Wistar rat incision wound model. Two experimental wounds about 5 cm long were created on each side of dorsal midline. Each animal received two sutures-Horsehair 4-0 and Ethilon 4-0. The sutured areas were grossly examined on 3rd and 7th days for visual observations like congestion, edema, infection, wound disruption, and impression of suture material on healed wound and then subjected for histological study. Results: Revealed that horsehair has got diameter of 0.19 mm which complies with the 4-0 size USP standard. Straight pull tensile strength was found 0.5851 ± 0.122 kg and knot pull tensile strength was 0.3998 ± 0.078 kg, which complies with the standards of United State Pharmacopia for class II nonabsorbable suture materials. In vivo study revealed that there was no evidence of edema, congestion, and discharge in both the groups. Wounds healed with minimum impressions of suture material with minimum scar mark. Mean histological scoring shows very mild tissue reaction. Conclusion: Horsehair has got properties of standard suture material except low tensile strength and hence can be used in reconstructive, plastic surgeries, and ophthalmic surgeries. PMID:24459386

  1. [Suture foreign body reaction as a mammographic pitfall].

    PubMed

    Plagborg, G J; Andersen, H K

    2000-02-14

    A mammographic pitfall is presented. After lumpectomy owing to cancer in the breast a woman developed an immediate allergic reaction presumably caused by the subcutaneous sutures (vicryl). After adjuvant irradiation the breast became swollen and mammography gave suspicion of a recurrent breast cancer. Surgical excision was performed and examination of the biopsy specimen showed a foreign body reaction to the suture material with fibrosis and eosinophilia. PMID:10740437

  2. A new design of a Nitinol ring-like wire for suturing in deep surgical field.

    PubMed

    Nespoli, Adelaide; Dallolio, Villiam; Villa, Elena; Passaretti, Francesca

    2015-11-01

    The present work proposes a new suturing procedure based on self-accommodating suture points. Each suture point is made of a commercial NiTi wire hot-shaped in a single loop ring; a standard suture needle is then fixed at one end of the NiTi suture. According to this simple geometry, several NiTi suture stitches have been prepared and tested by tensile test to verify the closing force in comparison to that of commercial sutures. Further experimental tests have also been performed on anatomic samples from animals to verify the handiness of the NiTi suture. Moreover, surface quality of sutures has been carefully investigated via microscopy. Results show that the NiTi suture expresses high stiffness and a good surface quality. In addition, the absence of manual knotting allows for a simple, fast and safe procedure. PMID:26249562

  3. Effect of nylon bag and protozoa on in vitro corn starch disappearance.

    PubMed

    van Zwieten, J T; van Vuuren, A M; Dijkstra, J

    2008-03-01

    An in vitro experiment was carried out to study whether the presence of protozoa in nylon bags can explain the underestimation of the in situ degradation of slowly degradable starch. Corn of a high (flint) and a low (dent) vitreousness variety was ground over a 3-mm screen, weighed in nylon bags with a pore size of 37 microm, and washed in cold water. Samples of washed cornstarch were incubated in 40-mL tubes with faunated and defaunated ruminal fluid. An additional amount of washed corn, in nylon bags, was inserted in each incubation tube. Incubations were carried out for 0, 2, 4, 6, 12, and 24 h, and starch residue in tube and nylon bag was determined. In general, starch disappearance from the nylon bag was less than from the tube, and was less with faunated than defaunated rumen fluid, but corn variety did not affect starch disappearance. When no protozoa were present, the disappearance of starch from the bags was higher after 6 and 12 h incubation compared with presence of protozoa. However, in the tubes, there was no difference in starch disappearance due to presence or absence of protozoa. Estimated lag time was higher in presence (4.6 h) then absence (3.6 h) of protozoa. It was concluded that the effect of presence or absence of protozoa on starch disappearance differs within or outside nylon bags. The reduced disappearance rate of starch inside the nylon bags in the presence of protozoa helps to explain the underestimation of starch degradation based on the in sacco procedure when compared with in vivo data upon incubation of slowly degradable starch sources. PMID:18292269

  4. Suture Forces in Undersized Mitral Annuloplasty: Novel Device and Measurements

    PubMed Central

    Siefert, Andrew; Pierce, Eric; Lee, Madonna; Jensen, Morten; Aoki, Chikashi; Takebayashi, Satoshi; Gorman, Robert; Gorman, Joseph; Yoganathan, Ajit

    2014-01-01

    Purpose: Demonstrate the first use of a novel technology for quantifying suture forces on annuloplasty rings to better understand the mechanisms of ring dehiscence. Description: Force transducers were developed, attached to a size 24 Physio™ ring, and implanted in the mitral annulus of an ovine animal. Ring suture forces were measured after implantation and for cardiac cycles reaching peak left ventricular pressures (LVP) of 100, 125, and 150 mmHg. Evaluation: After implanting the undersized ring to the flaccid annulus, the mean suture force was 2.0±0.6 N. During cyclic contraction, anterior ring suture forces were greater than posterior ring suture forces at peak LVPs of 100 mmHg (4.9±2.0 N vs. 2.1±1.1 N), 125 mmHg (5.4±2.3 N vs. 2.3±1.2 N), and 150 mmHg (5.7±2.4 N vs. 2.4±1.1 N). The largest force was 7.4 N at 150 mmHg. Conclusions: Preliminary results demonstrate trends in annuloplasty suture forces and their variation with location and LVP. Future studies will significantly contribute to clinical knowledge by elucidating the mechanisms of ring dehiscence while improving annuloplasty ring design and surgical repair techniques. PMID:24996707

  5. Bearing area: a new indication for suture anchor pullout strength?

    PubMed

    Yakacki, Christopher Michael; Griffis, Jack; Poukalova, Mariya; Gall, Ken

    2009-08-01

    Studies performed to quantify the pullout strength of suture anchors have not adequately defined the basic device parameters that control monotonic pullout. The bearing area of a suture anchor can be used to understand and predict anchor pullout strength in a soft-bone model. First, conical-shaped test samples were varied in size and shape and tested for pullout in 5, 8, and 10 pcf sawbone models. Next, bearing area and pullout strength relationships developed from the test samples were validated against nine commercially available suture anchors, including the Mitek QuickAnchor and SpiraLok, Opus Magnum(2), ArthroCare ParaSorb, and Arthrex BioCorkscrew. The samples showed a direct correlation between bearing area and pullout strength. Increased insertion depth was a secondary condition that also increased pullout strength. The pullout strength for the suture anchors followed the predicted trends of conical devices based on their individual bearing areas. For the 5 and 8 pcf models, only two and three devices, respectively, fell outside the predicted pullout strength range by more than a standard deviation. The use of a synthetic sawbone model was validated against the pullout strength of an Arthrex Corkscrew in five fresh-frozen cadaver humeral heads. The bearing area of a suture anchor can be used to predict the pullout strength independent of design in a soft-bone model. This work helps provide a foundation to understand the principles that affect the pullout strength of suture anchors. PMID:19226593

  6. Iatrogenic Ulnar Nerve Injury post Laceration Suturing - An Unusual Presentation

    PubMed Central

    Mothilal, Murali; Mothilal, S N; Ravichandran, S; Mohammad, Jamal

    2013-01-01

    Introduction: Nerve entrapment while suturing a lacerated wound is a complication that is easily avoidable. We report a case low ulnar nerve palsy due to nerve entrapment while suturing a lacerated wound. Case Report: A 48 year old lady came with complaints of pain and a lacerated wound over the dorsomedial aspect of lower third of the left forearm. The lacerated wound was sutured elsewhere one week back. She had fracture of lower third of the ulna which was stabilised with plates and screws using a separate dorsal incision. She developed ulnar claw hand on the third postoperative day. Strength duration curve revealed neurotmesis of ulnar nerve. Ulnar nerve exploration was done and the nerve was found to be ligated at the site of original laceration. The ligature was released and nerve was found to be thinned out at the site. There was no neurological recovery at 5 months follow up and reconstruction procedures in form of tendon tranfer are planned for the patient. Conclusion: This is a case of iatrogenic ulnar nerve palsy which is very rare in our literature. This can be easily avoided if proper care is taken while suturing the primary laceration. A nerve can be mistakenly sutured for a bleeding vein and proper exposure while suturing will be necessary especially at areas where nerves are superficial. PMID:27298911

  7. Scar tissue orientation in unsutured and sutured corneal wound healing.

    PubMed Central

    Melles, G R; Binder, P S; Beekhuis, W H; Wijdh, R H; Moore, M N; Anderson, J A; SundarRaj, N

    1995-01-01

    AIMS--This study aimed to evaluate stromal wound healing morphology in short term unsutured compared with sutured corneal wounds, to define regional variation in healing within radial keratotomy wounds. METHODS--Stromal scar tissue orientation (fibroblast and collagen fibre orientation) was analysed in unsutured and adjacent sutured keratotomy wounds in monkeys, 2 to 9 weeks after surgery, using light and transmission electron microscopy. RESULTS--At 2 to 4 weeks, scar tissue orientation was transverse to the wound edge in unsutured wounds, but sagittal in sutured wounds. At 5 to 9 weeks, a reorientation of scar tissue sagittal to the wound was seen in the unsutured wounds, proceeding from the posterior to anterior wound regions. In sutured wounds, a scar tissue reorientation transverse to the wound was seen, proceeding from the anterior wound region in a posterior direction. CONCLUSIONS--Within the same cornea, sutured and unsutured wounds showed opposite patterns of healing. Sutured wounds initially healed more slowly, but obtained pseudolamellar continuity over time. In contrast, healing of unsutured wounds was characterised by an early approximation towards lamellar repair that was followed by an ineffective reorganisation of the scar. This latter pattern of healing, that may be associated with a variable weakening of the wound, may relate to the clinical findings of unpredictability and/or progression of refractive effect following radial keratotomy. Images PMID:7547789

  8. Clinical outcomes of suture delay in forehead flap.

    PubMed

    Isik, Daghan; Kiroglu, Faruk; Isik, Yasemin; Goktas, Ugur; Atik, Bekir

    2012-01-01

    The delay phenomenon is a surgical procedure performed to raise a wider skin flap and to improve the survival of skin flaps. Surgery, chemicals, sutures, and lasers can be used for the delay procedure. In this study, delayed forehead flaps created by suturing were used for coverage of nasal skin defects in eleven patients. In 7 patients, the cross-paramedian forehead flap was used to increase the extent of flap lengthening. In the first session, suture delay was performed on both sides of the forehead flap margin. In the second session, the flap was elevated and sutured to its new position, 7 to 10 days after the initial surgery. All flaps were completely viable, and patient satisfaction was optimal in all cases. The positive effect of surgical delay on flap survival has been shown in experimental and clinical studies. However, experimentally, suture delay or chemical delay procedures have been shown to be beneficial in flap survival only. Suture delay seems to be an inexpensive, effective, easily performed, atraumatic, and safe technique, especially among patients with systemic diseases such as diabetes or cardiovascular diseases, smoking patients who may lose the flap, or patients who need very wide and long flaps. PMID:22337378

  9. Study on the effects of nylon-chitosan-blended membranes on the spheroid-forming activity of human melanocytes.

    PubMed

    Lin, Sung-Jan; Hsiao, Wen-Chu; Jee, Shiou-Hwa; Yu, Hsin-Su; Tsai, Tsen-Fang; Lai, Juin-Yih; Young, Tai-Horng

    2006-10-01

    Though reported limitedly in tissue engineering, modification of cellular functions can be achieved by culturing them into multicellular spheroids. We have shown melanocytes form spheroids on chitosan surface. However, how biomaterials promote spheroid formation has never been systemically investigated. In this work, nylon, which inhibits melanocyte spheroid formation, and chitosan, which promotes melanocyte spheroid formation, are used to prepare nylon/chitosan-blended membranes. Membranes composed of pure nylon, pure chitosan and various ratios of nylon and chitosan are employed to examine their effects on spheroid formation. Melanocytes show better adhesion to nylon membranes than that to chitosan membranes. In blended membranes, as more nylon is incorporated, cell adhesion increases and the trend for spheroid formation decreases. Melanocytes can only form spheroids on membranes with poorer cell adhesion. Examining the surface of the blended membranes shows phase separation of nylon and chitosan. As nylon content increases, the nylon phase on the membrane surface increases and thereby enhances cell adhesion. The opposite trend for cell adhesion and spheroid formation substantiates our hypothesis of spheroid formation on biomaterials: a balance between cell-substrate interaction and cell-cell interaction. The decrease in cell-substrate interaction tilts the balance to a state more favorable for spheroid formation. Our work can serve as a model to investigate the relative strengths of cell-cell and cell-substrate interactions and also pave way to design blended membranes with desired physical properties while preserving the spheroid-forming activity. PMID:16777216

  10. Mechanical Properties of Laser-Sintered-Nylon Diamond Lattices

    NASA Astrophysics Data System (ADS)

    Neff, Clayton

    Additive manufacturing offers a manufacturing technique to produce complex geometry prototypes at a rapid pace and low cost. These advantages advocate additive manufacturing for the design and production of cellular structures. Cellular structures are interesting because they contain a large amount of porosity (void space of air) to manifest a lightweight structure. Designs of cellular structures generate a periodic pattern; often of complex geometry, called a lattice. There has been a significant amount of research to maximize specific stiffness of lattice structures but little to evaluate low-stiffness lattices. Low-stiffness structures benefit energy absorbance through bending of the lattice. This research seeks to assess diamond lattices as low stiffness, bending structures. The research involves PA2200 (Nylon 12) laser sintered diamond lattices with experimental compression testing and direct FEA model comparison. A correction factor is applied for a design offset of laser sintered lattices. Once applied, the experimental and FEA data agree in validating the diamond lattice as a bending-dominated structure. Diamond lattices show a 4th order relationship between stiffness and parameters of thickness and unit cell length. For density, stiffness maintains a 2nd order relationship, as predicted by bending dominated structures. The resulting stiffness can be tuned over a stiffness range of four orders of magnitude. Further research shows the results for modifying the diamond lattice and scaling stiffness and density using other materials (like metals) to expand the range of stiffness and compare diamond lattices on material property charts. Lastly, the effective Poisson's ratio varies from 0.5 to 0.4 depending on the (t/L) ratio.

  11. EELS Analysis of Nylon 6 Nanofibers Reinforced with Nitroxide-Functionalized Graphene Oxide.

    PubMed

    Leyva-Porras, César; Ornelas-Gutiérrez, C; Miki-Yoshida, M; Avila-Vega, Yazmín I; Macossay, Javier; Bonilla-Cruz, José

    2014-01-01

    A detailed analysis by transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) of nitroxide-functionalized graphene oxide layers (GOFT) dispersed in Nylon 6 nanofibers is reported herein. The functionalization and exfoliation process of graphite oxide to GOFT was confirmed by TEM using electron diffraction patterns (EDP), wherein 1 to 4 graphene layers of GOFT were observed. The distribution and alignment of GOFT layers within a sample of Nylon 6 nanofiber reveals that GOFT platelets are mainly within the fiber, but some were partially protruding from it. Furthermore, Nylon 6 nanofibers exhibit an average diameter of 225 nm with several microns in length. GOFT platelets embedded into the fiber, the pristine fiber, and amorphous carbon were analyzed by EELS where each spectra [corresponding to the carbon edge (C-K)] exhibited changes in the fine structure, allowing a clear distinction between: i) GOFT single-layers, ii) Nylon-6 nanofibers, and iii) the carbon substrate. EELS analysis is presented here for the first time as a powerful tool to identify functionalized graphene single-layers (< 4 layers of GOFT) into a Nylon 6 nanofiber composite. PMID:24634536

  12. EELS Analysis of Nylon 6 Nanofibers Reinforced with Nitroxide-Functionalized Graphene Oxide

    PubMed Central

    Leyva-Porras, César; Ornelas-Gutiérrez, C.; Miki-Yoshida, M.; Avila-Vega, Yazmín I.; Macossay, Javier; Bonilla-Cruz, José

    2014-01-01

    A detailed analysis by transmission electron microscopy (TEM) and electron energy loss spectroscopy (EELS) of nitroxide-functionalized graphene oxide layers (GOFT) dispersed in Nylon 6 nanofibers is reported herein. The functionalization and exfoliation process of graphite oxide to GOFT was confirmed by TEM using electron diffraction patterns (EDP), wherein 1 to 4 graphene layers of GOFT were observed. The distribution and alignment of GOFT layers within a sample of Nylon 6 nanofiber reveals that GOFT platelets are mainly within the fiber, but some were partially protruding from it. Furthermore, Nylon 6 nanofibers exhibit an average diameter of 225 nm with several microns in length. GOFT platelets embedded into the fiber, the pristine fiber, and amorphous carbon were analyzed by EELS where each spectra [corresponding to the carbon edge (C-K)] exhibited changes in the fine structure, allowing a clear distinction between: i) GOFT single-layers, ii) Nylon-6 nanofibers, and iii) the carbon substrate. EELS analysis is presented here for the first time as a powerful tool to identify functionalized graphene single-layers (< 4 layers of GOFT) into a Nylon 6 nanofiber composite. PMID:24634536

  13. Crystalline Morphology and Polymorphic Phase Transitions in Electrospun Nylon-6 Nanofibers

    SciTech Connect

    Liu,Y.; Cui, L.; Guan, F.; Gao, Y.; Hedin, N.; Zhu, L.; Fong, H.

    2007-01-01

    Uniform nylon-6 nanofibers with diameters around 200 nm were prepared by electrospinning. Polymorphic phase transitions and crystal orientation of nylon-6 in unconfined (i.e., as-electrospun) and a high T{sub g} (340 C) polyimide confined nanofibers were studied. Similar to melt-spun nylon-6 fibers, electrospun nylon-6 nanofibers also exhibited predominant, metastable {gamma}-crystalline form, and the {gamma}-crystal (chain) axes preferentially oriented parallel to the fiber axis. Upon annealing above 150 C, {gamma}-form crystals gradually melted and recrystallized into thermodynamically stable {alpha}-form crystals, which ultimately melted at 220 C. Release of surface tension accompanied this melt-recrystallization process, as revealed by differential scanning calorimetry. For confined nanofibers, both the melt-recrystallization and surface tension release processes were substantially depressed; {gamma}-form crystals did not melt and recrystallize into {alpha}-form crystals until 210 C, only 10 C below the T{sub m} at 220 C. After complete melting of nanoconfined crystals at 240 C and recrystallization at 100 C, only {alpha}-form crystals oriented perpendicular to the nanofiber axis were obtained. In the polyimide-confined nanofibers, the Brill transition (from the monoclinic {alpha}-form to a high-temperature monoclinic form) was observed at 180-190 C, which was at least 20 C higher than that in unconfined nylon-6 at {approx}160 C. This, again, was attributed to the confinement effect.

  14. Nylon and teflon scribe effect on NBR to Chemlok 233 and NBR to NBR bond interfaces

    NASA Technical Reports Server (NTRS)

    Jensen, S. K.

    1990-01-01

    A study was requested by Manufacturing Engineering to determine what effects marking with nylon (6/6) and Teflon scribes may have on subsequent bonding. Witness panel bond specimens were fabricated by the development lab to test both acrylonitrile butadiene rubber (NBR) to Chemlok and NBR to NBR after controlled exposure. The nylon rod used as a scribe tool demonstrates virtually no bond deterioration when used to scribe lines on either the Chemlok to NBR surfaces or the NBR to NBR interface. Lab test results indicate that the nylon rod-exposed samples produce tensile and peel values very similar to the control samples and the Teflon exposed samples produce tensile and peel values much lower than the control samples. Visual observation of the failure surfaces of the tested samples shows that Teflon scribing produces an obvious contamination to the surface and the nylon produces no effect. Photographs of test samples are provided. It is concluded that Teflon stock used as a scribe tool on a Chemlok 233 to NBR surface or an NBR to NBR surface has a detrimental effect on the bond integrity on either of these bond interfaces. Therefore, it is recommended that the nylon rod continue to be used where a scribe line is required in the redesigned solid rocket motor segment insulation layup operations. The use of Teflon scribes should not be considered.

  15. Nylon 6-Gold Nanoparticle Composite Fibers for Colorimetric Detection of Urinary 1-Hydroxypyrene

    NASA Astrophysics Data System (ADS)

    Ifegwu, O. Clinton; Anyakora, C.; Torto, N.

    2015-05-01

    A one-step in situ synthesis of nylon 6 nanofibers filled with gold nanoparticles for the colorimetric probe of 1-hydroxypyrene, a biomarker associated with the largest class of cancer-causing chemical compounds polycyclic aromatic hydrocarbons (PAHs) is proposed in this study. The gold nanoparticles (AuNPs) were successfully embedded on the surface of the nylon 6 fibers where the gold particles were chemisorbed onto the amide groups in the nylon 6 backbones. By electrospinning the nylon 6/gold nanocomposite, the gold nanoparticles were uniformly dispersed on the polymer fibers to give a photostable reddish white fiber which turned purple/blue when brought in contact with a standard solution of the biomarker. The TEM revealed the formation of spherical AuNPs with an average diameter of 8 nm well arrayed within the nanofibers, but no significant change in the morphology of the nanofibers was observed. The thermal properties of the composite fibers were greatly improved compared to the electrospun nylon 6 fiber. The developed method described herein is simple, effective, requires no post-treatments, and is highly sensitive (100 ng/ml) hence the nanocomposite fibers can be employed as a test strip for the colorimetric detection of 1-hydroxypyrene in human urine or other diagnostic probe biosensors.

  16. Comparison of computed tomography dose index in polymethyl methacrylate and nylon dosimetry phantoms.

    PubMed

    Sookpeng, Supawitoo; Cheebsumon, Patsuree; Pengpan, Thanyawee; Martin, Colin

    2016-01-01

    The use of computed tomography (CT) scanning has been growing steadily. Therefore, CT dose measurement is becoming increasingly important for patient protection and optimization. A phantom is an important tool for dose measurement. This paper focuses on the evaluation of a CT dosimetry phantom made from nylon, instead of the standard polymethyl methacrylate (PMMA), which is not readily available or is too expensive in some countries. Comparison between phantoms made from the two materials is made in terms of measurements of the CT dose indices (CTDI). These were measured for four different beam widths and kVp settings at the center and periphery in head and body phantoms made from both materials and weighted CTDIs (CTDIw) were calculated. CT numbers along the z-axis of the phantom were also measured at the center and four peripheral positions of each scanned slice to check phantom homogeneity. Results showed that values for the CTDIw measured in the nylon phantoms were slightly higher than those from the PMMA while CT numbers for nylon were lower than those of PMMA. This is because the mass attenuation coefficient of the nylon is higher. Nylon could be used as a substitute material for CT dosimetry phantom to enable measurements and adjustment factors are given which could be used to estimate PMMA values for making comparisons with displayed values. PMID:27051170

  17. Experimental and Computational Analysis of Cellular Interactions with Nylon-3-Bearing Substrates

    PubMed Central

    Liu, Runhui; Vang, Kang Z.; Kreeger, Pamela K.; Gellman, Samuel H.; Masters, Kristyn S.

    2012-01-01

    The ability to design biomaterials that interact with biological environments in a predictable manner necessitates an improved understanding of how surface chemistry influences events such as protein adsorption and cell adhesion. In this work, we examined mechanisms governing the interactions between 3T3 fibroblasts and nylon-3 polymers, which have a protein-like polyamide backbone and are highly amenable to tuning of chemical and physical properties. Protein adsorption and cell adhesion to a library of nylon-3 polymers were characterized and analyzed by partial least squares regression. This analysis revealed that specific chemical features of the nylon-3 polymers correlated with the extent of protein adsorption, which, in turn, correlated with cell adhesion in a serum-containing environment. In contrast, in a serum-free environment, cell adhesion could be predicted solely from chemical properties. Enzymatic treatments of 3T3 cells prior to plating indicated that proteins bound to the cell surface mediated cell-nylon-3 polymer interactions under serum-free conditions, with additional analysis suggesting that cell-associated fibronectin played a dominant role in adhesion in the absence of serum. The mechanistic insight gained from these studies can be used to inform the design of new polymer structures in addition to providing a basis for continued development of nylon-3 copolymers for tissue engineering applications. PMID:22623026

  18. Comparison of computed tomography dose index in polymethyl methacrylate and nylon dosimetry phantoms

    PubMed Central

    Sookpeng, Supawitoo; Cheebsumon, Patsuree; Pengpan, Thanyawee; Martin, Colin

    2016-01-01

    The use of computed tomography (CT) scanning has been growing steadily. Therefore, CT dose measurement is becoming increasingly important for patient protection and optimization. A phantom is an important tool for dose measurement. This paper focuses on the evaluation of a CT dosimetry phantom made from nylon, instead of the standard polymethyl methacrylate (PMMA), which is not readily available or is too expensive in some countries. Comparison between phantoms made from the two materials is made in terms of measurements of the CT dose indices (CTDI). These were measured for four different beam widths and kVp settings at the center and periphery in head and body phantoms made from both materials and weighted CTDIs (CTDIw) were calculated. CT numbers along the z-axis of the phantom were also measured at the center and four peripheral positions of each scanned slice to check phantom homogeneity. Results showed that values for the CTDIw measured in the nylon phantoms were slightly higher than those from the PMMA while CT numbers for nylon were lower than those of PMMA. This is because the mass attenuation coefficient of the nylon is higher. Nylon could be used as a substitute material for CT dosimetry phantom to enable measurements and adjustment factors are given which could be used to estimate PMMA values for making comparisons with displayed values. PMID:27051170

  19. Lateral meniscus allograft transplantation: an arthroscopically-assisted single-incision technique using all-inside sutures with a suture hook.

    PubMed

    Lee, Su-Chan; Chang, Woo-Hyuk; Park, Seung-Jun; Kim, Tae-Ho; Sung, Byung-Yoon

    2014-02-01

    We present an arthroscopically-assisted single-incision technique using all-inside sutures with a suture hook in the lateral meniscus allograft transplantation. Although this technique is technically demanding, it provides vertically oriented and secure sutures with good tissue approximation without the accessory skin incision. PMID:23328984

  20. Disposable circumcision suture device: clinical effect and patient satisfaction.

    PubMed

    Lv, Bo-Dong; Zhang, Shi-Geng; Zhu, Xuan-Wen; Zhang, Jie; Chen, Gang; Chen, Min-Fu; Shen, Hong-Liang; Pei, Zai-Jun; Chen, Zhao-Dian

    2014-01-01

    In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture device (DCSD). A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group). Patients in the DCSD group were anesthetized with compound 5% lidocaine cream, the others with a 2% lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were significantly lower in the Shang ring and suture device groups compared to the conventional group (P < 0.001). Intra-operative pain was less in the suture device group compared with the other two groups (P < 0.001); whereas post-operative pain was higher in the conventional group compared to the other two groups (P < 0.001). Patients in the suture device (80.57%) and Shang ring (73.57%) groups were more satisfied with penile appearances compared with the conventional circumcision group (20.06%, P < 0.05). Patients in suture device group also healed markedly faster than the conventional group (P < 0.01). The overall satisfaction rate was better in the suture device group (78.66%) compared with the conventional (47.13%) and Shang ring (50.00%) groups (P < 0.05). The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra-operative and post-operative pain and improved patient satisfaction with the cosmetic appearances. PMID:24759586

  1. Diminished suture strength after robotic needle driver manipulation.

    PubMed

    Ricchiuti, Daniel; Cerone, Jeffrey; Shie, Scott; Jetley, Ajay; Noe, Donald; Kovacik, Mark

    2010-09-01

    Robot-assisted minimally invasive surgery has become a routine surgical option for the treatment of prostate cancer. Despite its technical advancements, the da Vinci(®) Surgical System still lacks haptic feedback to the surgeon, resulting in a maximally applied compressive force by the robotic needle driver during every grasping maneuver. Without this perceptional sense of touch and grip control, repetitive robotic needle driver manipulation may unknowingly lead to irreparable damage to fine sutures used during delicate anastomotic repairs. For robotic prostatectomy, any such loss of integrity can potentially lead to premature breakdown of the urethrovesical anastomosis and urine extravasation, especially important for a less-than-perfectly fashioned anastomotic repair. Although it has already been established that overhandling of sutures using handheld laparoscopic instruments can lead to reduced suture strength, it has not been established to what extent this may occur after robotic surgical procedures. We present analytical data and analyses concerning the failure strength of fine sutures commonly used for urethrovesical anastomotic repair during robotic prostatectomy, after repetitive robotic needle driver manipulation. When compared with noncompromised monofilament suture controls, the average maximal failure force after repetitive robotic manipulation was significantly reduced by 35% (p < 0.0001). Similarly, the average maximal failure force of braided sutures was significantly reduced after repetitive robotic manipulation by 3% (p = 0.009). This work demonstrates that significant reductions in monofilament and braided suture strength integrity can occur after customary repetitive manipulation by robotic needle drivers in an ex vivo model, with further research warranted in the in vivo setting. PMID:20653422

  2. Disposable circumcision suture device: clinical effect and patient satisfaction

    PubMed Central

    Lv, Bo-Dong; Zhang, Shi-Geng; Zhu, Xuan-Wen; Zhang, Jie; Chen, Gang; Chen, Min-Fu; Shen, Hong-Liang; Pei, Zai-Jun; Chen, Zhao-Dian

    2014-01-01

    In our experience patients undergoing circumcision are mostly concerned about pain and penile appearances. We conducted a prospective randomized trial to assess the benefits of a new disposable circumcision suture device (DCSD). A total of 942 patients were equally divided into three groups (conventional circumcision, Shang ring and disposable suture device group). Patients in the DCSD group were anesthetized with compound 5% lidocaine cream, the others with a 2% lidocaine penile block. Operation time, intra-operative blood loss, incision healing time, intra-operative and post-operative pain, the penile appearance and overall satisfaction degree were measured. Operation time and intra-operative blood loss were significantly lower in the Shang ring and suture device groups compared to the conventional group (P < 0.001). Intra-operative pain was less in the suture device group compared with the other two groups (P < 0.001); whereas post-operative pain was higher in the conventional group compared to the other two groups (P < 0.001). Patients in the suture device (80.57%) and Shang ring (73.57%) groups were more satisfied with penile appearances compared with the conventional circumcision group (20.06%, P < 0.05). Patients in suture device group also healed markedly faster than the conventional group (P < 0.01). The overall satisfaction rate was better in the suture device group (78.66%) compared with the conventional (47.13%) and Shang ring (50.00%) groups (P < 0.05). The combination of DCSD and lidocaine cream resulted in shorter operation and incision healing times, reduced intra-operative and post-operative pain and improved patient satisfaction with the cosmetic appearances. PMID:24759586

  3. Flexible prototype thermoelectric devices based on Ag2Te and PEDOT:PSS coated nylon fibre

    NASA Astrophysics Data System (ADS)

    Finefrock, Scott W.; Zhu, Xiaoqin; Sun, Yanming; Wu, Yue

    2015-03-01

    p- and n-type Ag2Te nanocrystals are coated separately onto nylon fibres to create flexible composites. A prototype thermoelectric device made using such fibres produces ~0.8 nW in a 20 K temperature difference. This is improved to over 5 nW by using a conducting polymer as the p-type material.p- and n-type Ag2Te nanocrystals are coated separately onto nylon fibres to create flexible composites. A prototype thermoelectric device made using such fibres produces ~0.8 nW in a 20 K temperature difference. This is improved to over 5 nW by using a conducting polymer as the p-type material. Electronic supplementary information (ESI) available: Sheet resistance of Ag2Te nanocrystal coated nylon fibre mesh made using nanocrystals of various sizes. Details of MMR Seebeck coefficient measurements. See DOI: 10.1039/c5nr00058k

  4. Micro-nano hierarchically structured nylon 6,6 surfaces with unique wettability.

    PubMed

    Zhang, Liang; Zhang, Xiaoyan; Dai, Zhen; Wu, Junjie; Zhao, Ning; Xu, Jian

    2010-05-01

    A micro-nano hierarchically structured nylon 6,6 surface was easily fabricated by phase separation. Nylon 6,6 plate was swelled by formic acid and then immersed in a coagulate bath to precipitate. Micro particles with nano protrusions were generated and linked together covering over the surface. After dried up, the as-formed surface showed superhydrophilic ability. Inspired by lotus only employing 2-tier structure and ordinary plant wax to maintain superhydrophobicity, paraffin wax, a low surface energy material, was used to modify the hierarchically structured nylon 6,6 surface. The resultant surface had water contact angle (CA) of 155.2+/-1.3 degrees and a low sliding angle. The whole process was carried on under ambient condition and only need a few minutes. PMID:20144830

  5. A study on electrospun nylon-6/TiO2 composite nanofibers

    NASA Astrophysics Data System (ADS)

    Nirmala, R.; Won, Jeong Jin; Kim, Hak Yong; Navamathavan, R.; Chuan, Yi; El-Newehy, Mohamed; Al-Deyab, Salem S.

    2012-05-01

    We report on the preparation and the characterization of TiO2 nanoparticles incorporated with nylon-6 composite nanofibers by using electrospinning technique. Two different composite nanofiber mats with TiO2 nanoparticles sizes of 20 and 300 nm were prepared. The resultant nanofibers exhibited good incorporation of TiO2 nanoparticles. The doping of TiO2 nanoparticles into the nylon-6 nanofibers was confirmed by using scanning electron microscopy (SEM), high-resolution transmission electron microscopy (HR-TEM), X-ray diffraction (XRD) and energy dispersive X-ray (EDX) spectroscopy. The measurement of the electrical conductivity of the TiO2 nanoparticles incorporated with nylon-6 nanofibers were carried out. Current-voltage (I-V) characteristics revealed that the current was enhanced for the sample with 300 nm TiO2 nanoparticles compared to that with 20-nm TiO2 nanoparticles.

  6. Fabrication and characterization of silver- and copper-coated Nylon 6 forcespun nanofibers by thermal evaporation

    SciTech Connect

    Mihut, Dorina M. Lozano, Karen; Foltz, Heinrich

    2014-11-01

    Silver and copper nanoparticles were deposited as thin films onto substrates consisting of Nylon 6 nanofibers manufactured using forcespinning{sup ®} equipment. Different rotational speeds were used to obtain continuous nanofibers of various diameters arranged as nonwoven mats. The Nylon 6 nanofibers were collected as successive layers on frames, and a high-vacuum thermal evaporation method was used to deposit the silver and copper thin films on the nanofibers. The structures were investigated using scanning electron microscopy–scanning transmission electron microscopy, atomic force microscopy, x-ray diffraction, and electrical resistance measurements. The results indicate that evaporated silver and copper nanoparticles were successfully deposited on Nylon 6 nanofibers as thin films that adhered well to the polymer substrate while the native morphology of the nanofibers were preserved, and electrically conductive nanostructures were achieved.

  7. Interfacial adhesion in rayon/nylon sheath/core composite fibers

    SciTech Connect

    Tao Weiying.

    1991-01-01

    The fibers with enhanced adhesion were produced using a wire coating type process. One objective was to determine an effective coupling agent and the most-appropriate application conditions for maximum interfacial adhesion in the rayon/nylon bicomponent fibers. The second objective was to characterize the interfacial adhesion between the core fiber and the rayon skin. After removal of the spin finish by water washing, the nylon core fibers were pretreated with fumaric acid (FA) as an adhesion promoter and then were coated with viscose rayon. The results indicated that the interfacial adhesion in the rayon/nylon composite fibers was significantly improved under the application conditions of 1.0% with 36 second pretreatment time, 1.5% with 18 second pretreatment, and 2% with 9 second pretreatment time. A fiber pull adhesion test method was developed to test the interfacial adhesion. This method effectively determined the adhesion between the core and the skin.

  8. Modeling and flow analysis of pure nylon polymer for injection molding process

    NASA Astrophysics Data System (ADS)

    Nuruzzaman, D. M.; Kusaseh, N.; Basri, S.; Oumer, A. N.; Hamedon, Z.

    2016-02-01

    In the production of complex plastic parts, injection molding is one of the most popular industrial processes. This paper addresses the modeling and analysis of the flow process of the nylon (polyamide) polymer for injection molding process. To determine the best molding conditions, a series of simulations are carried out using Autodesk Moldflow Insight software and the processing parameters are adjusted. This mold filling commercial software simulates the cavity filling pattern along with temperature and pressure distributions in the mold cavity. In the modeling, during the plastics flow inside the mold cavity, different flow parameters such as fill time, pressure, temperature, shear rate and warp at different locations in the cavity are analyzed. Overall, this Moldflow is able to perform a relatively sophisticated analysis of the flow process of pure nylon. Thus the prediction of the filling of a mold cavity is very important and it becomes useful before a nylon plastic part to be manufactured.

  9. Recovery of hydrophobicity of nylon aged by heat and saline water

    SciTech Connect

    Tokoro, Tetsuro; Hackam, R.

    1996-12-31

    The recovery of hydrophobicity of Nylon after aging by long exposure to a stress of saline water at different temperatures is investigated. The hydrophobicity is determined by measuring the contact angle of a droplet of distilled water on Nylon. The aging of Nylon was done by immersing it for up to 336 h in saline water solutions in the range 5.0 {times} 10{sup 5} {micro}S/cm. The aging temperatures were 0 to 98 C. After aging, the specimens were kept in air at room temperature for up to 4,500 h during which the recovery of hydrophobicity and weight changes were measured. Specimens were also kept in high vacuum for 20 h to determine the changes in the contact angle and in the weight with the absence of air.

  10. New meniscus repair by an all-inside knot suture technique.

    PubMed

    Fukushima, Kazumasa; Okano, Tatsumasa; Negishi, Shinichi; Horaguchi, Takashi; Sato, Kenji; Saito, Akiyoshi; Ryu, Junnosuke

    2005-06-01

    The indications for the all-inside knot suture technique include tears in the red-red zone or red-white zone in the meniscus, and a horizontal tear, a vertical tear, and a peripheral tear. First, find an appropriate place for a suture insertion site with a Kateran needle or a spinal needle. Make sure it exits beyond the tear in the meniscus. Once the insertion site is chosen, a suture is passed into and through the joint. The suture is slowly pulled back. You should be able to feel the tip of the suture come out of the joint capsule. If you want to make a vertical suture to suture the tear, move the suture vertically apex. Then insert the suture back into the joint through the capsule. Make sure the suture stays inside the joint. Find and grab the suture with a punch inserted from the clear cannula. Pull the suture out of the joint through the clear cannula with the punch. Tighten the knot with a knot pusher. Then confirm the stability of the sutured site with the probe. Our all-inside knot suture technique can be performed arthroscopically, allowing reliable repair of the torn meniscus. PMID:15944646

  11. A comparison of absorbable suture and argon laser welding for lateral repair of arteries.

    PubMed

    Lawrence, P F; Li, K; Merrell, S W; Goodman, G R

    1991-08-01

    Conventional vascular anastomoses between autogenous vessels are performed with nonabsorbable sutures. Recently, use of absorbable sutures and laser-assisted vascular anastomoses has been advocated because of their improved healing characteristics. This study compared arterial repairs with the argon laser, absorbable suture, and nonabsorbable suture for technical characteristics including additional suture and overall success rates, burst strength, and cost. Absorbable and nonabsorbable suture closures were comparable with respect to technique, but laser-assisted vascular anastomosis was technically more demanding and required almost twice as much time for completion. The argon laser successfully closed only 58.6% of the arteriotomies, and 90% of the closures required additional sutures for complete hemostasis. All sutured arteriotomies were successfully completed by use of either absorbable or nonabsorbable suture. Burst strength was similar for all groups, but was uniformly greater than 300 mm Hg for sutured repairs, whereas two of five laser-assisted closures burst below 300 mm Hg. Finally, costs for purchasing ($35,000) and operating ($300/hr.) an argon laser make laser-assisted vascular anastomosis much more expensive than sutured repair. These data suggest argon laser-assisted vascular anastomoses are more technically demanding, less successful, and more expensive than conventional sutured anastomoses when evaluated in large caliber arteries in a canine model. Absorbable suture, however, is comparable to conventional nonabsorbable sutured arterial repairs in expense, handling characteristics, and success rates with the added advantage of eliminating permanent foreign body in the arterial wall when it is absorbed. PMID:1861329

  12. The relative efficiency of nylon and cotton gill nets for taking lake trout in Lake Superior

    USGS Publications Warehouse

    Pycha, Richard L.

    1962-01-01

    The change from cotton to nylon twine for gill nets in 1949–52 resulted in a sharp increase in the efficiency of the most important gear used for taking lake trout in Lake Superior, and, consequently, biased estimates of fishing intensity and abundance severely.From early May to the end of September 1961, short gangs (2000 or 4000 linear feet) of cotton and nylon nets were fished in parallel sets for lake trout. A total of 343,000 feet of gill netting was lifted. Nylon nets were 2.25 times as efficient as cotton nets for taking legal-sized fish and 2.8 times as efficient for undersized lake trout. The average lengths of legal, undersized, and all lake trout taken in nets of the two materials did not differ greatly. The percentage of the catch which was undersized (less than 1.25 lb, dressed weight) was 20.8 in nylon nets and 17.7 in cotton. The relative efficiency of cotton and nylon nets showed no trend during the season. The efficiency ratio determined in this study was closely similar to that obtained by earlier workers.Correction of estimates of fishing intensity and abundance for the greater efficiency of the nylon nets used since 1951 has not been attempted. The drastic decline of the lake trout fishery has forced fishermen to make changes in fishing practices in the past few years that cause new bias of an unknown extent to estimates of fishing intensity.

  13. Suspension of the gluteal region with silhouette sutures.

    PubMed

    de Benito, Javier; Pizzamiglio, Roberto

    2013-09-01

    The authors present their minimally invasive gluteopexy technique, using polypropylene 2-0 sutures with 10 absorbable polylactic cones in their distal section (Silhouette Lift, Irvine, California) to improve the anteroposterior projection of the gluteal region. Histological study of the reaction of adipose tissue surrounding the cones previously has shown that, 3 months after insertion of the sutures, fibrous scar tissue is sufficiently developed to resist the weight of the tissues. On the basis of this finding, the authors decided to perform the gluteopexy with sutures, in 2 surgical steps. During the first step, the sutures are inserted in the adipose tissue without any proximal fixation. In the second step, performed 3 months after the first procedure when the fibrous reaction is more solid, the sutures are tightened to obtain the gluteopexy. Among the advantages of this technique are its simplicity, the fact that it produces no traumatic effects, and the fact that it can be performed with local anesthetic, reducing surgical time. It is also possible to combine this procedure with lipofilling or liposuction techniques. PMID:24084884

  14. Recognizing surgeon's actions during suture operations from video sequences

    NASA Astrophysics Data System (ADS)

    Li, Ye; Ohya, Jun; Chiba, Toshio; Xu, Rong; Yamashita, Hiromasa

    2014-03-01

    Because of the shortage of nurses in the world, the realization of a robotic nurse that can support surgeries autonomously is very important. More specifically, the robotic nurse should be able to autonomously recognize different situations of surgeries so that the robotic nurse can pass necessary surgical tools to the medical doctors in a timely manner. This paper proposes and explores methods that can classify suture and tying actions during suture operations from the video sequence that observes the surgery scene that includes the surgeon's hands. First, the proposed method uses skin pixel detection and foreground extraction to detect the hand area. Then, interest points are randomly chosen from the hand area so that their 3D SIFT descriptors are computed. A word vocabulary is built by applying hierarchical K-means to these descriptors, and the words' frequency histogram, which corresponds to the feature space, is computed. Finally, to classify the actions, either SVM (Support Vector Machine), Nearest Neighbor rule (NN) for the feature space or a method that combines "sliding window" with NN is performed. We collect 53 suture videos and 53 tying videos to build the training set and to test the proposed method experimentally. It turns out that the NN gives higher than 90% accuracies, which are better recognition than SVM. Negative actions, which are different from either suture or tying action, are recognized with quite good accuracies, while "Sliding window" did not show significant improvements for suture and tying and cannot recognize negative actions.

  15. Selective laser vaporization of polypropylene sutures and mesh

    NASA Astrophysics Data System (ADS)

    Burks, David; Rosenbury, Sarah B.; Kennelly, Michael J.; Fried, Nathaniel M.

    2012-02-01

    Complications from polypropylene mesh after surgery for female stress urinary incontinence (SUI) may require tedious surgical revision and removal of mesh materials with risk of damage to healthy adjacent tissue. This study explores selective laser vaporization of polypropylene suture/mesh materials commonly used in SUI. A compact, 7 Watt, 647-nm, red diode laser was operated with a radiant exposure of 81 J/cm2, pulse duration of 100 ms, and 1.0-mm-diameter laser spot. The 647-nm wavelength was selected because its absorption by water, hemoglobin, and other major tissue chromophores is low, while polypropylene absorption is high. Laser vaporization of ~200-μm-diameter polypropylene suture/mesh strands, in contact with fresh urinary tissue samples, ex vivo, was performed. Non-contact temperature mapping of the suture/mesh samples with a thermal camera was also conducted. Photoselective vaporization of polypropylene suture and mesh using a single laser pulse was achieved with peak temperatures of 180 and 232 °C, respectively. In control (safety) studies, direct laser irradiation of tissue alone resulted in only a 1 °C temperature increase. Selective laser vaporization of polypropylene suture/mesh materials is feasible without significant thermal damage to tissue. This technique may be useful for SUI procedures requiring surgical revision.

  16. MATERIAL PROPERTIES OF COMMON SUTURE MATERIALS IN ORTHOPAEDIC SURGERY

    PubMed Central

    Najibi, S; Banglmeier, R; Matta, JM; Tannast, M

    2010-01-01

    Suture materials in orthopaedic surgery are used for closure of wounds, repair of fascia, muscles, tendons, ligaments, joint capsules, and cerclage or tension band of certain fractures. The purpose of this study was to compare the biomechanical properties of eleven commonly used sutures in orthopaedic surgery. Three types of braided non-absorbable and one type of braided absorbable suture material with different calibers (n=77) underwent biomechanical testing for maximum load to failure, strain, and stiffness. All samples were tied by one surgeon with a single SMC (Seoul Medical Center) knot and three square knots. The maximum load to failure and strain were highest for #5 FiberWire and lowest for #0 Ethibond Excel (p<0.001). The stiffness was highest for #5 FiberWire and lowest for #2-0 Vicryl (p<0.001). In all samples, the failure of the suture material occurred at the knot There was no slippage of the knot in any of the samples tested. This data will assist the orthopaedic surgeon in selection and application of appropriate suture materials and calibers to specific tasks. PMID:21045977

  17. Preparation and XPS study of X-ray photochromic transparent BiOI/nylon11 composite film

    NASA Astrophysics Data System (ADS)

    Zhao, Zhijuan; Liu, Fen; Zhao, Liangzhong; Yan, Shouke

    2011-06-01

    Nylon11 film immersed in BiI3-ethanol solution was used for in situ generation of transparent BiOI/nylon11 X-ray photochromic composite materials via integration of the hydrolyzate (BiOI) of BiI3 into nylon11. The obtained BiOI/nylon11 composite film shows a reversible photochromic effect, changing the color from orange-red to brownish black under soft X-ray irradiation and back to orange-red after air exposure. X-ray photoelectron spectroscopy (XPS) results show that the oxidation state of Bi atoms in BiOI/nylon11 composite film does not change before and after changing the color. Angle-resolved XPS analysis reveals that BiOI in nylon11 film is well distributed within an infiltration depth of about 10 nm. The source of the X-ray photochromic effect for transparent BiOI/nylon11 composite film may be related to oxygen as well as the interaction between BiOI and the amide groups. The oxygen AT% in the composite film decreases with increasing X-ray irradiation time. The present method for preparing transparent BiOI/nylon11 X-ray photochromic composite materials is facile and low cost. The X-ray photochromic effect has potential applications in some technology fields. For example, it can be used to create temporary patterning in a colored composite material surface.

  18. Radiation processing of Nylon 6 by e-beam for improved properties and performance

    NASA Astrophysics Data System (ADS)

    Pramanik, N. K.; Haldar, R. S.; Bhardwaj, Y. K.; Sabharwal, S.; Niyogi, U. K.; Khandal, R. K.

    2009-03-01

    Percent water absorption of Nylon 6 was reduced substantially when irradiated by e-beam radiation in presence of triallyl isocyanurate. Hardness, tensile strength, flexural strength, and impact resistance of Nylon 6 were also improved with the dose of e-beam radiation. Improvement of mechanical properties and reduction of water absorption were due to the cross-linking of polyamide molecules in the presence of high-energy radiation. Increase of cross-linking with increasing radiation dose was verified by the increase of gel content at higher doses.

  19. Is the Kapuskasing structure the site of a cryptic suture

    NASA Technical Reports Server (NTRS)

    Burke, K.

    1983-01-01

    The demonstration that the Kapuskasing structure involves substantial thrusting of deep continental crustal rocks over shallower continental rocks calls into question an earlier suggestion (by Wilson) that the Circum-Ungaua suture zone continued through the Kapuskasing to join the Penokean fold belt (implying that the Kapuskasing marked the site of what has since come to be called a cryptic suture). Problems are discussed which arose in attempting to reconcile Wilson's idea with data from more recent studies: whether the Kapuskasing and the Thompson belt both mark sutures of about 1700 Ma age; why there is no age difference across the Kapuskasing if it does mark the site of continental collision, and why there is no offset of Superior subprovinces across the Kapuskasing.

  20. Delayed-onset endophthalmitis associated with corneal suture infections

    PubMed Central

    2013-01-01

    Background The purpose of the current study was to report the microbiology, risk factors, and treatment outcomes in patients with delayed-onset endophthalmitis associated with corneal suture infections. For this retrospective consecutive case series, a search of the ocular microbiology department database was performed to identify all patients with positive corneal and intraocular cultures (anterior chamber and/or vitreous) between 01 January 1995 and 01 January 2010. A subset of patients with a history of corneal suture infections and delayed-onset endophthalmitis was identified. Results Over the 15-year period of the study, 68 patients were identified to have both positive corneal and intraocular cultures. Among them, six patients were identified to have a culture-proven, delayed-onset endophthalmitis that developed from a culture-positive corneal suture infection. All of the patients in the current study were using topical corticosteroids at the time of diagnosis. In four of six patients, there was documented manipulation of a suture before the development of endophthalmitis. Streptoccocus was identified as the causative organism in five of six patients in the current study. All of the Streptoccocus isolates were sensitive to vancomycin. The single case of Serratia marcescens endophthalmitis was sensitive to amikacin, ceftazidime, ciprofloxacin, gentamicin, and tobramycin. Treatment modalities varied and were guided by the attending ophthalmologist depending upon clinical presentation. One patient with severe Streptococcus pyogenes keratitis and endophthalmitis underwent a primary enucleation after developing a wound dehiscence. Of the remaining five patients, all received topical and intravitreal antibiotics. Therapeutic penetrating keratoplasty was performed in three patients. Pars plana vitrectomy was performed in two patients. Visual acuity outcomes ranged from 20/150 to no light perception. Conclusions In the current study, Streptococcus was isolated in

  1. Total laparoscopic hysterectomy via suture and ligation technique

    PubMed Central

    Kang, Hye Won; Lee, Ji Won; Kim, Ho Yeon; Kim, Bo Wook

    2016-01-01

    Objective The term 'total laparoscopic hysterectomy (TLH) with classical suture method' refers to a surgical procedure performed using only sutures and ligations with intracorporeal or extracorporeal ties, without using any laser or electronic cauterization devices during laparoscopic surgery as in total abdominal hysterectomy. However, the method is not as widely used as electric coagulation equipment for TLH because further advances in technology and surgical technique are required and operative time can take longer. In the current study, we evaluated the benefits of the classical suture method for TLH. Methods This study retrospectively reviewed patients who received TLH using the classical suture method from August 2005 to April 2014. The patients' baseline characteristics were analyzed, including age, parity, cause of operation, medical and surgical history. Surgical outcomes analyzed included the weight of the uterus, operative time, complications, changes in hemoglobin level, blood transfusion requirements, and postoperative hospital stay. Results Of 746 patients who underwent TLH with the classical suture method, mean operation time was 96.9 minutes. Mean average decline in hemoglobin was 1.6 g/dL and transfusion rate was 6.2%. Urinary tract injuries were reported in 8 patients. Urinary tract injuries comprised 6 cases of bladder injury and 3 cases of ureter injury. There were no cases of vaginal stump infection, hematoma, bowel injury or abdominal wound complication. All cases involving complications occurred before 2010. Conclusion The classical suture method for TLH presents tolerable levels of complications and blood loss. Advanced surgical skill is expected to decrease operation time and complications. PMID:26866034

  2. Force-Induced Craniosynostosis in the Murine Sagittal Suture

    PubMed Central

    Oppenheimer, Adam J.; Rhee, Samuel T.; Goldstein, Steven A.; Buchman, Steven R.

    2010-01-01

    BACKGROUND The etiology of non-syndromic craniosynostosis remains elusive. While compressive forces have been implicated in premature suture fusion, conclusive evidence of force-induced craniosynostosis is lacking. The purpose of this study was to determine if cyclical loading of the murine calvarium could induce suture fusion. METHODS Calvarial coupons from post-natal day 21, B6CBA wild-type mice (n = 18) were harvested and cultured. A custom appliance capable of delivering controlled, cyclical, compressive loads was applied perpendicular to the sagittal suture within the coupon in vitro. Nine coupons were subjected to 0.3g of force for 30 minutes each day for a total of 14 days. A control group of nine coupons was clamped in the appliance without loading. Analysis of suture phenotype was performed using alkaline phosphatase and H&E staining techniques, as well as in situ hybridization analysis using Bone Sialoprotein (BSP). RESULTS Control group sagittal sutures—which normally remain patent in mice—showed their customary histological appearance. In contradistinction, sagittal sutures subjected to cyclic loading showed histological evidence of premature fusion (craniosynostosis). In addition, alkaline phosphatase activity and BSP expression was observed to be increased in the experimental group when compared to matched controls. CONCLUSIONS An in vitro model of forced-induced craniosynostosis has been devised. Premature fusion of the murine sagittal suture was induced with the application of controlled, cyclical, compressive loads. These results implicate abnormal forces in the development of non-syndromic craniosynostosis, which supports our global hypothesis that epigenetic phenomena have a crucial role in the pathogenesis of craniosynostosis. PMID:19952640

  3. Influence of metopic suture fusion associated with sagittal synostosis.

    PubMed

    Domeshek, Leahthan F; Das, Rajesh R; Van Aalst, John A; Mukundan, Srinivasan; Marcus, Jeffrey R

    2011-01-01

    Some patients with sagittal synostosis present with a fused metopic suture. We hypothesize that premature metopic suture fusion consistently and identifiably alters form associated with sagittal synostosis. We previously validated three-dimensional vector analysis as a tool for the study of cranial morphology and used it herein to distinguish between dysmorphologies of isolated sagittal synostosis (ISS) and combined sagittal-metopic synostosis (CSM). Preoperative computed tomographic scans for patients with ISS and CSM were compared with matched normative counterparts. Premature metopic suture fusion was defined by established radiographic criteria. Color-coded point clouds were created for each scan, with color gradient based on patient deviation from normal across the dysmorphic skull. Standard deviation data were evaluated in 7 cranial regions and compared between ISS and CSM. Mean ISS and CSM point clouds were evaluated. Using three-dimensional vector analysis, standard anthropometric data/indices were determined and compared between the 2 groups. Differences in ISS and CSM regional deviations and index measurements were not statistically significant. Mean ISS and CSM representations depicted similar overall morphology. Using accepted criteria for identification of metopic synostosis in CSM, only subtle differences appear between the 2 populations on average. Expected morphologic changes associated with metopic synostosis are present in only a small number of patients with CSM, arguing against our hypothesis, and calling into question the criteria used to identify premature metopic suture fusion. Normal metopic suture fusion occurs for a continuum of time. Our findings suggest that the normal continuum may begin earlier than the literature suggests. In the setting of sagittal synostosis, the influence of metopic suture fusion and treatment is best determined by individual morphologic analysis. PMID:21187774

  4. Familial idiopathic hypertrophic osteoarthropathy and cranial suture defects in children

    SciTech Connect

    Reginato, A.J.; Schiapachasse, V.; Guerrero, R.

    1982-05-01

    Three children with idiopathic hypertrophic osteoarthropathy and cranial suture defects are reported. The syndrome was recognized after birth and in the two oldest siblings, the cranial defects and subperiosteal bone formation resolved almost completely by age 4 and 6 years. The joint swelling and clubbing persisted and mild bone reabsorption of the distal phalanges became apparent at an older age. Two siblings and both parents had normal bone X-rays and no clubbing. This study confirms the association of cranial sutural defects and familial idopathic hypertrophic osteoarthropathy.

  5. A carpal ligament substitute part 1: polyester suture.

    PubMed

    Martin, John A; Wehbé, Marwan A

    2013-02-01

    We have searched for a synthetic substitute for the carpal ligaments, which would be widely available and easy to use. Four loops of 2-0 polyester fiber suture (Mersilene) were found to exceed the ultimate tensile strength of the scapholunate interosseous ligament. This construct approximates a normal ligament stress/strain curve and can theoretically facilitate fibrous tissue ingrowth. It is readily available, easy to handle, and inexpensive. Based on these findings, we recommend the use of polyester suture in the reconstruction of carpal and other ligaments. PMID:23168035

  6. Conductive nylon fabric through in situ synthesis of nano-silver: Preparation and characterization.

    PubMed

    Montazer, M; Komeily Nia, Z

    2015-11-01

    A simple, green and low cost method based on Tollens' reagent is presented to synthesize a nano-conductive silver layer on nylon 6 fabric. The nylon fabric was first treated with potassium permanganate to oxidize fabric surface and thereby, increasing the number of assembled particles on the fabric surface. SEM images indicated distribution of silver nanoparticles on the fabric surface and formation of nanolayer on the fiber surface. EDX and XRD patterns confirmed assembling silver nanoparticles on the nylon fibers. The treated fabrics displayed a very low electrical resistivity i.e. 4.5Ω/sq. Furthermore, the fabric color was indicated by a reflectance spectrophotometer in order to study the effects of the synthesized nanoparticles on the fabric color. It is also indicated that oxidation process has no significant influence on the mechanical properties of the fabric, and nano-treatment revenged the negative effect of oxidation of nylon fabric. Moreover, silver nanoparticles imparted reasonable antibacterial properties to the fabric against Staphylococcus aureus. PMID:26249599

  7. TREATMENT AND PRODUCT RECOVERY: SUPERCRITICAL WATER OXIDATION OF NYLON MONOMER MANUFACTURING WASTE

    EPA Science Inventory

    EPA GRANT NUMBER: R822721C569
    Title: Treatment and Product Recovery: Supercritical Water Oxidation of Nylon Monomer Manufacturing Waste
    Investigator: Earnest F. Gloyna
    Institution: University of Texas at Austin
    EPA Project Officer:<...

  8. Highly conductive and flexible nylon-6 nonwoven fiber mats formed using tungsten atomic layer deposition.

    PubMed

    Kalanyan, Berç; Oldham, Christopher J; Sweet, William J; Parsons, Gregory N

    2013-06-12

    Low-temperature vapor-phase tungsten atomic layer deposition (ALD) using WF6 and dilute silane (SiH4, 2% in Ar) can yield highly conductive coatings on nylon-6 microfiber mats, producing flexible and supple nonwovens with conductivity of ∼1000 S/cm. We find that an alumina nucleation layer, reactant exposure, and deposition temperature all influence the rate of W mass uptake on 3D fibers, and film growth rate is calibrated using high surface area anodic aluminum oxide. Transmission electron microscopy (TEM) reveals highly conformal tungsten coatings on nylon fibers with complex "winged" cross-section. Using reactant gas "hold" sequences during the ALD process, we conclude that reactant species can transport readily to reactive sites throughout the fiber mat, consistent with conformal uniform coverage observed by TEM. The conductivity of 1000 S/cm for the W-coated nylon is much larger than found in other conductive nonwovens. We also find that the nylon mats maintain 90% of their conductivity after being flexed around cylinders with radii as small as 0.3 cm. Metal ALD coatings on nonwovens make possible the solvent-free functionalization of textiles for electronic applications. PMID:23724894

  9. The nylon scintillator containment vessels for the Borexino solar neutrino experiment

    NASA Astrophysics Data System (ADS)

    Cadonati, L.; Calaprice, F.; Galbiati, C.; Pocar, A.; Shutt, T.

    2014-06-01

    The neutrino event rate in the Borexino scintillator is very low ( 0.5 events per day per ton) and concentrated in an energy region well below the 2.6 MeV threshold of natural radioactivity. The intrinsic radioactive contaminants in the photomultipliers (PMTs), in the Stainless Steel Sphere, and in other detector components, play special requirements on the system required to contain the scintillator. The liquid scintillator must be shielded from the Stainless Steel Sphere and from the PMTs by a thick barrier of buffer fluid. The fluid barrier, in addition, needs to be segmented in order to contain migration of radon and daughters emanated by the Stainless Steel Sphere and by the PMTs. These requirements were met by designing and building two spherical vessel made of thin nylon film. The inner vessel contains the scintillator, separating it from the surrounding buffer. The buffer region itself is divided into two concentric shells by the second, outer nylon vessel. In addition, the two nylon vessels must satisfy stringent requirements for radioactivity and for mechanical, optical and chemical properties. This paper describes the requirements of the the nylon vessels for the Borexino experiment and offers a brief overview of the construction methods adopted to meet those requirements.

  10. One-step synthesis of silver nanoparticle-filled Nylon 6 nanofibers and their antibacterial properties

    Technology Transfer Automated Retrieval System (TEKTRAN)

    A novel and facile one-step approach to in situ synthesize silver nanoparticle-filled nylon 6 nanofibers by electrospinning is reported. The method does not need post-treatments and can be carried out at ambient conditions without using additional chemicals. It employs the electrospinning solvent as...

  11. Degradation mechanisms of nylon separator materials for a nickel-cadmium cell in KOH electrolytes

    SciTech Connect

    Lim, H.S.; Margerum, J.D.; Verzwyvelt, S.A.; Lackner, A.M.; Knechtli, R.C.

    1989-03-01

    Degradation reactions of a nylon 6 battery separator material have been studied in 4-34% aqueous KOH electrolytes at 35/sup 0/-110/sup 0/C. In a Ni/Cd cell, this degradation involves a slow hydrolysis reaction followed by fast electrochemical oxidations of the hydrolysis reaction products. Arrhenius activation energy of the hydrolysis reaction in 34% KOH was 20.0 +- 0.3 kcal/mole. A plot of the hydrolysis rate at 100/sup 0/C vs. hydroxyl ion concentration gave a rate maximum at about 16% KOH, and the mechanism for this effect is discussed. Electrochemical oxidations of the hydrolysis product, 6-aminocaproate ion, appear to proceed rapidly in several sequential steps at a nickel oxide electrode. In a Ni/Cd cell, the combination of nylon separator hydrolysis followed by electrochemical oxidation of the products can seriously degrade the battery lifetime. The rate of the hydrolysis of nylon 66 separator material was approximately one half of that of the nylon 6 material.

  12. Ultraviolet-induced irreversible tensile actuation of diacetylene/nylon microfibers

    NASA Astrophysics Data System (ADS)

    Chun, Kyoung-Yong; Choi, Changsoon; Baughman, Ray H.; Kim, Seon Jeong

    2016-07-01

    Photomechanically irreversible tensile-actuated diacetylene-embedding nylon 6/6 microfibers were investigated. 10,12-pentacosadiynoic acid (PCDA) monomer, which have conventionally provided a visual color change by temperature and photo-driven stimuli, was embedded in nylon 6/6 microfibers by wet spinning. By ultraviolet (UV) (254 nm) exposure, we observed irreversible tensile actuation (contraction) of linear (untwisted) and helical (twisted) structural microfibers. The tensile contraction of twisted nylon 6/6-PCDA microfiber containing10 mM PCDA was reached to ∼2% at 60 °C. Such irreversible tensile contraction can be promoted by volume contraction of PCDA monomers during UV exposure along with irregular structural deformation containing gauche conformation with increasing temperature. The kinetics of tensile contraction with temperature and time were shown by the Arrhenius plots. The activation energies were 34.3–35.7 kJ mol‑1 as increasing the concentration of PCDA, implies that the nylon 6/6-PCDA microfibers could be applied to show time-temperature integrated device.

  13. Tensile testing of nylon and Kevlar parachute materials under Federal specified temperature and relative humidity conditions

    SciTech Connect

    Botner, W.T.

    1980-01-01

    A small 10-ft x 12-ft temperature and relative humidity controlled room for tensile testing of parachute materials is presented. Tensile tests of nylon and Kevlar parachute materials indicate there is a negligible change in break strength of test samples soaked in the controlled environment vs samples soaked in ambient conditions.

  14. Complexity of suture zones:Example from the Yarlung Zangbo Suture Zone , southern Tibet. (Invited)

    NASA Astrophysics Data System (ADS)

    Hebert, R.; Guilmette, C.

    2013-12-01

    Decade-long investigation of the Yarlung Zangbo Suture Zone (YZSZ), southern Tibet, has revealed it's high complexity in terms of structure, geochronology and metamorphic and igneous histories. For instance, YZSZ comprises Late Devonian to mid-Miocene rocks, metamorphic intensities vary from high-grade to very-low grade and deformation styles range from ductile to brittle. Late Devonian rocks (363.7 × 1.7 Ma) are alkalic gabbros resulting from activity of a plume active within the Paleo-Tethys basin. Two ophiolite sub-groups are recognized. Sub-group 1 is Mid- to Late Jurassic (150-177 Ma) in age and ill-defined because only few sequences have been found and studied so far. IThis sub-group is probably derived from the destruction of a marginal basin comprising intra-oceanic arc and fore-arc settings. Spontang and Zedong sequences are good examples of this sub-group. Sub-group 2 is Lower Cretaceous (120-130 Ma) and represents the destruction of a marginal basin comprising an arc-back-arc system. These ophiolites are spatially associated with ophiolitic mélanges and flysch respectively representing the reworking of the Cretaceous ophiolites and Indian continental margin and the Neo-Tethyan ocean floor although such affinities need clarification. Most ophiolitic sequences belong to sub-group 2 such as Xiugubagu, Saga, Xigaze. Amphibolite and garnet amphibolite blocks (123-130 Ma) found within the ophiolitic mélange share similar geochemical attributes with sub-group 2 ophiolites. Their protoliths were probably generated within back-arc spreading center and metamorphosed in a subduction zone at depth around 50 km. Some radiometric ages suggest events at 80 Ma and 90 old represent the entry of Indian continental margin into the intra-oceanic subduction zone and/or obduction of ophiolites. However these ages seem to be very rare throughout the whole suture zone and are therefore considered as resulting from local metamorphic events. Some alkaline igneous rocks (131

  15. Crystalline Morphology and Polymorphic Phase Transitions in Electrospun Nylon 6 Nanofibers

    PubMed Central

    Liu, Yi; Cui, Li; Guan, Fangxiao; Gao, Yi; Hedin, Nyle E.; Zhu, Lei; Fong, Hao

    2008-01-01

    Uniform nylon 6 nanofibers with diameters around 200 nm were prepared by electrospinning. Polymorphic phase transitions and crystal orientation of nylon 6 in unconfined (i.e., as-electrospun) and a high Tg (340 °C) polyimide confined nanofibers were studied. Similar to melt-spun nylon 6 fibers, electrospun nylon 6 nanofibers also exhibited predominant, meta-stable γ crystalline form, and the γ-crystal (chain) axes preferentially oriented parallel to the fiber axis. Upon annealing above 150 °C, γ-form crystals gradually melted and recrystallized into the thermodynamically stable α-form crystals, which ultimately melted at 220 °C. Release of surface tension accompanied this melt-recrystallization process, as revealed by differential scanning calorimetry. For confined nanofibers, both the melt-recrystallization and surface tension release processes were substantially depressed; γ-form crystals did not melt and recrystallize into α-form crystals until 210 °C, only 10 °C below the Tm at 220 °C. After complete melting of nano-confined crystals at 240 °C and recrystallization at 100 °C, only α-form crystals oriented perpendicular to the nanofiber axis were obtained. In the polyimide-confined nanofibers, the Brill transition (from the monoclinic α-form to a high temperature monoclinic form) was observed at 180–190 °C, which was at least 20 °C higher than that in unconfined nylon 6 at approximately 160 °C. This, again, was attributed to the confinement effect. PMID:18698379

  16. Crystalline Morphology and Polymorphic Phase Transitions in Electrospun Nylon 6 Nanofibers.

    PubMed

    Liu, Yi; Cui, Li; Guan, Fangxiao; Gao, Yi; Hedin, Nyle E; Zhu, Lei; Fong, Hao

    2007-01-01

    Uniform nylon 6 nanofibers with diameters around 200 nm were prepared by electrospinning. Polymorphic phase transitions and crystal orientation of nylon 6 in unconfined (i.e., as-electrospun) and a high T(g) (340 degrees C) polyimide confined nanofibers were studied. Similar to melt-spun nylon 6 fibers, electrospun nylon 6 nanofibers also exhibited predominant, meta-stable gamma crystalline form, and the gamma-crystal (chain) axes preferentially oriented parallel to the fiber axis. Upon annealing above 150 degrees C, gamma-form crystals gradually melted and recrystallized into the thermodynamically stable alpha-form crystals, which ultimately melted at 220 degrees C. Release of surface tension accompanied this melt-recrystallization process, as revealed by differential scanning calorimetry. For confined nanofibers, both the melt-recrystallization and surface tension release processes were substantially depressed; gamma-form crystals did not melt and recrystallize into alpha-form crystals until 210 degrees C, only 10 degrees C below the T(m) at 220 degrees C. After complete melting of nano-confined crystals at 240 degrees C and recrystallization at 100 degrees C, only alpha-form crystals oriented perpendicular to the nanofiber axis were obtained. In the polyimide-confined nanofibers, the Brill transition (from the monoclinic alpha-form to a high temperature monoclinic form) was observed at 180-190 degrees C, which was at least 20 degrees C higher than that in unconfined nylon 6 at approximately 160 degrees C. This, again, was attributed to the confinement effect. PMID:18698379

  17. Biomechanical trial of modified flexor tendon sutures: an in vitro study.

    PubMed

    Vlajcic, Zlatko; Zic, Rado; Skenderi, Zenun; Bilic-Zulle, Lidija; Martic, Kresimir; Stanec, Zdenko

    2012-09-01

    Proven benefits of early active mobilisation for intra-synovial flexor tendon repairs have inducted new criteria for a 'perfect suture'. This study has examined different variations of modified Kessler's suture, which could fulfil the new criteria. A total of 93 swine extensor tendons were transected, repaired and tested using a dynamometer with constant rate of extension. The first part of study tested clinically the most used modified Kessler suture, a variation of double modified Kessler suture and intact tendons as a control group. Further variations in the second part of study were due to type of suture, location and number of the knots and type of peripheral suture. According to the results, the tested version of double modified Kessler suture with crossed peripheral suture was the strongest one among all tested variations. The ultimate force for the authors preferred modification of the double modified Kessler (DMK) is significantly higher than modified Kessler suture. The version of DMK with crossed peripheral suture is the strongest one among all tested variations. The lowest strength manifests variation with two knots between tendon ends. The variations with interlocked and outsided knot or monofilament tread are not statistically significant regarding ultimate force. The frequency of suture failure events (suture pull out or tendon and/or suture rupture) is equal respecting braided or monofilament suture. The preferred modification of the double modified Kessler (DMK) suture with crossed peripheral suture is the strongest one among all tested variations and could achieve, concerning range of force, early active mobilisation. Further variations due to the type of thread and location, type and number of the knots did not show statistical significance. PMID:22784225

  18. Comparison of the cheese-wiring effects among three sutures used in rotator cuff repair

    PubMed Central

    Lambrechts, Mark; Nazari, Behrooz; Dini, Arash; O'Brien, Michael J.; Heard, Wendell M. R.; Savoie, Felix H.; You, Zongbing

    2014-01-01

    Purpose: The goal of this study was to compare the cheese-wiring effects of three sutures with different coefficients of friction. Materials and Methods: Sixteen human cadaveric shoulders were dissected to expose the distal supraspinatus and infraspinatus muscle tendons. Three sutures were stitched through the tendons: #2 Orthocord™ suture (reference #223114, DePuy Mitek, Inc., Raynham, MA), #2 ETHIBOND* EXCEL Suture, and #2 FiberWire® suture (FiberWire®, Arthrex, Naples, FL). The sutures were pulled by cyclic axial forces from 10 to 70 N at 1 Hz for 1000 cycles through a MTS machine. The cut-through distance on the tendon was measured with a digital caliper. Results: The cut-through distance in the supraspinatus tendons (mean ± standard deviation, n = 12) were 2.9 ± 0.6 mm for #2 Orthocord™ suture, 3.2 ± 1.2 mm for #2 ETHIBOND* suture, and 4.2 ± 1.7 mm for #2 FiberWire® suture. The differences were statistically significant analyzing with analysis of variance (P = 0.047) and two-tailed Student's t-test, which showed significance between Orthocord™ and FiberWire® sutures (P = 0.026), but not significant between Orthocord™ and ETHIBOND* sutures (P = 0.607) or between ETHIBOND* and FiberWire® sutures (P = 0.103). Conclusion: The cheese-wiring effect is less in the Orthocord™ suture than in the FiberWire® suture in human cadaveric supraspinatus tendons. Clinical Relevance: Identification of sutures that cause high levels of tendon cheese-wiring after rotator cuff repair can lead to better suture selection. PMID:25258499

  19. Angiogenesis and osteogenesis in an orthopedically expanded suture

    NASA Technical Reports Server (NTRS)

    Chang, H. N.; Garetto, L. P.; Potter, R. H.; Katona, T. R.; Lee, C. H.; Roberts, W. E.

    1997-01-01

    The purpose of this study was to examine the angiogenic and the subsequent osteogenic responses during a 96-hour time-course after sutural expansion. Fifty rats were divided into: (1) a control group that received only angiogenic induction through injection of 5 ng/gm recombinant human endothelial cell growth factor (rhECGF); (2) an experimental group that received orthopedic expansion and rhECGF; (3) a sham group that received expansion and sodium chloride (NaCl) injection; and (4) a baseline group that received no expansion or injection. All rats were injected with 3H-thymidine (1.0 microCi/gm) 1 hour before death to label the DNA of S-phase cells. Demineralized sections (4 microm thick) were stained with hematoxylin and eosin. Angiogenesis and cell migration were analyzed with a previously established cell kinetics model. Analysis of variance was used to test the hypothesis that enhancement of angiogenesis stimulates reestablishment of osteogenic capability. Blood vessel number, area, and endothelial cell-labeled index significantly increased in experimental groups, but no difference was found between control and baseline groups. Labeled-pericyte index and activated pericyte numbers in the experimental group were also higher than in the sham groups. These results show that supplemental rhECGF enhances angiogenesis in expanded sutures but not in nonexpanded sutures. Data also suggest that pericytes are the source of osteoblasts in an orthopedically expanded suture.

  20. 21 CFR 878.4840 - Absorbable polydioxanone surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable polydioxanone surgical suture. 878.4840 Section 878.4840 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... Industry and FDA.” See § 878.1(e) for the availability of this guidance document....

  1. 21 CFR 878.5035 - Nonabsorbable expanded polytetrafluoroethylene surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable expanded polytetrafluoroethylene surgical suture. 878.5035 Section 878.5035 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF...; Guidance for Industry and FDA.” See § 878.1(e) for the availability of this guidance document....

  2. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin...

  3. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin...

  4. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin...

  5. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin...

  6. 21 CFR 878.5010 - Nonabsorbable polypropylene surgical suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Nonabsorbable polypropylene surgical suture. 878.5010 Section 878.5010 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN... a monofilament, nonabsorbable, sterile, flexible thread prepared from long-chain polyolefin...

  7. Risk Factors for Mesh/Suture Erosion Following Sacrocolpopexy

    PubMed Central

    Cundiff, Geoffrey W.; Varner, Edward; Visco, Anthony G.; Zyczynski, Halina M.; Nager, Charles W.; Norton, Peggy A.; Schaffer, Joseph; Brown, Morton B.; Brubaker, Linda

    2008-01-01

    Objectives To identify risks for mesh/suture erosions following sacrocolpopexy (ASC). Study Design We analyzed demographic, perioperative variables and erosion status in 322 participants in the Colpopexy and Urinary Reduction Efforts study two years after sacrocolpopexy. Results The predominant graft used was synthetic mesh; Mersilene (42%) or Polypropylene (48%). Twenty subjects (6%) experienced mesh/suture erosion. Unadjusted risk factors for mesh/suture erosion were expanded polytrafluroethylene (ePTFE) mesh (ePTFE 4/21 (19%) versus non-ePFTE 16/301 (5%): OR 4.2), concurrent hysterectomy (OR 4.9) and current smoking (OR 5.2). Of those with mesh erosion, most affected women (13/17) underwent at least one surgery for partial or total mesh removal. Two were completely resolved, 6 had persistent problems and 5 were lost to follow-up. No resolution was documented in the 4 women who elected observation. Conclusions Expanded PTFE mesh should not be used for sacrocolpopexy. Concurrent hysterectomy and smoking are modifiable risks for mesh/suture erosion. PMID:18976976

  8. Use of Absorbable Sutures in Canine Carotid Arteries

    PubMed Central

    Rey, Alejandro R.; Carrillo-Farga, Joaquin; Velasco, Carlos O.; Valencia, Martin O.V.

    1990-01-01

    To study the functional and microstructural characteristics of polydioxanone sutures in vascular surgery, we created 48 vascular anastomoses in the right and left common carotid arteries of 24 mongrel dogs. In each animal, polydioxanone sutures were used in 1 carotid artery, and polypropylene sutures were used in the contralateral carotid artery. Twelve groups of 2 animals each were then formed. The 1st group was observed for 1 month, the 2nd for 2 months, the 3rd for 3 months, and so on until the 12th group, which was observed for 12 months. At the end of each observation period, reoperation was undertaken to evaluate the vascular anastomoses by means of angiography and microscopy. The polypropylene anastomoses showed a marked deformity, with tissue retraction and a foreign body reaction. In contrast, the polydioxanone anastomoses exhibited satisfactory healing, without deformity, and were well tolerated histologically. We believe that polydioxanone may be a useful, alternative vascular suture material. (Texas Heart Institute Journal 1990;17:99-102) Images PMID:15227391

  9. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Natural nonabsorbable silk surgical suture. 878.5030 Section 878.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  10. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Natural nonabsorbable silk surgical suture. 878.5030 Section 878.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  11. 21 CFR 878.5030 - Natural nonabsorbable silk surgical suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Natural nonabsorbable silk surgical suture. 878.5030 Section 878.5030 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES GENERAL AND PLASTIC SURGERY DEVICES Surgical Devices §...

  12. In situ Polymerization of Multi-Walled Carbon Nanotube/Nylon-6 Nanocomposites and Their Electrospun Nanofibers.

    PubMed

    Saeed, Khalid; Park, Soo-Young; Haider, Sajjad; Baek, Jong-Beom

    2009-01-01

    Multiwalled carbon nanotube/nylon-6 nanocomposites (MWNT/nylon-6) were prepared by in situ polymerization, whereby functionalized MWNTs (F-MWNTs) and pristine MWNTs (P-MWNTs) were used as reinforcing materials. The F-MWNTs were functionalized by Friedel-Crafts acylation, which introduced aromatic amine (COC(6)H(4)-NH(2)) groups onto the side wall. Scanning electron microscopy (SEM) images obtained from the fractured surfaces of the nanocomposites showed that the F-MWNTs in the nylon-6 matrix were well dispersed as compared to those of the P-MWNTs. Both nanocomposites could be electrospun into nanofibers in which the MWNTs were embedded and oriented along the nanofiber axis, as confirmed by transmission electron microscopy. The specific strength and modulus of the MWNTs-reinforced nanofibers increased as compared to those of the neat nylon-6 nanofibers. The crystal structure of the nylon-6 in the MWNT/nylon-6 nanofibers was mostly gamma-phase, although that of the MWNT/nylon-6 films, which were prepared by hot-pressing the pellets between two aluminum plates and then quenching them in icy water, was mostly alpha-phase, indicating that the shear force during electrospinning might favor the gamma-phase, similarly to the conventional fiber spinning. PMID:20596470

  13. Multifunctional ZnO/Nylon 6 nanofiber mats by an electrospinning-electrospraying hybrid process for use in protective applications

    NASA Astrophysics Data System (ADS)

    Vitchuli, Narendiran; Shi, Quan; Nowak, Joshua; Kay, Kathryn; Caldwell, Jane M.; Breidt, Frederick; Bourham, Mohamed; McCord, Marian; Zhang, Xiangwu

    2011-10-01

    ZnO/Nylon 6 nanofiber mats were prepared by an electrospinning-electrospraying hybrid process in which ZnO nanoparticles were dispersed on the surface of Nylon 6 nanofibers without becoming completely embedded. The prepared ZnO/Nylon 6 nanofiber mats were evaluated for their abilities to kill bacteria or inhibit their growth and to catalytically detoxify chemicals. Results showed that these ZnO/Nylon 6 nanofiber mats had excellent antibacterial efficiency (99.99%) against both the Gram-negative Escherichia coli and Gram-positive Bacillus cereus bacteria. In addition, they exhibited good detoxifying efficiency (95%) against paraoxon, a simulant of highly toxic chemicals. ZnO/Nylon 6 nanofiber mats were also deposited onto nylon/cotton woven fabrics and the nanofiber mats did not significantly affect the moisture vapor transmission rates and air permeability values of the fabrics. Therefore, ZnO/Nylon 6 nanofiber mats prepared by the electrospinning-electrospraying hybrid process are promising material candidates for protective applications.

  14. 21 CFR 878.4493 - Absorbable poly(glycolide/l-lactide) surgical suture.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Absorbable poly(glycolide/l-lactide) surgical....4493 Absorbable poly(glycolide/l-lactide) surgical suture. (a) Identification. An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared...

  15. 21 CFR 878.4493 - Absorbable poly(glycolide/l-lactide) surgical suture.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Absorbable poly(glycolide/l-lactide) surgical....4493 Absorbable poly(glycolide/l-lactide) surgical suture. (a) Identification. An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared...

  16. 21 CFR 878.4493 - Absorbable poly(glycolide/l-lactide) surgical suture.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Absorbable poly(glycolide/l-lactide) surgical....4493 Absorbable poly(glycolide/l-lactide) surgical suture. (a) Identification. An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared...

  17. 21 CFR 878.4493 - Absorbable poly(glycolide/l-lactide) surgical suture.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Absorbable poly(glycolide/l-lactide) surgical....4493 Absorbable poly(glycolide/l-lactide) surgical suture. (a) Identification. An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared...

  18. 21 CFR 878.4493 - Absorbable poly(glycolide/l-lactide) surgical suture.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Absorbable poly(glycolide/l-lactide) surgical....4493 Absorbable poly(glycolide/l-lactide) surgical suture. (a) Identification. An absorbable poly(glycolide/l-lactide) surgical suture (PGL suture) is an absorbable sterile, flexible strand as prepared...

  19. Effects of Citalopram on Sutural and Calvarial Cell Processes

    PubMed Central

    Durham, Emily; Jen, Serena; Wang, Lin; Nasworthy, Joseph; Elsalanty, Mohammed; Weinberg, Seth; Yu, Jack; Cray, James

    2015-01-01

    The use of selective serotonin reuptake inhibitors (SSRIs) for the treatment of depression during pregnancy is suggested to increase the incidence of craniofacial abnormalities including craniosynostosis. Little is known about this mechanism, however based on previous data we propose a mechanism that affects cell cycle. Excessive proliferation, and reduction in apoptosis may lead to hyperplasia within the suture that may allow for differentiation, bony infiltration, and fusion. Here we utilized in vivo and in vitro analysis to investigate this proposed phenomenon. For in vivo analysis we used C57BL–6 wild-type breeders treated with a clinical dose of citalopram during the third trimester of pregnancy to produce litters exposed to the SSRI citalopram in utero. At post-natal day 15 sutures were harvested from resulting pups and subjected to histomorphometric analysis for proliferation (PCNA) and apoptosis (TUNEL). For in vitro studies, we used mouse calvarial pre-osteoblast cells (MC3T3-E1) to assess proliferation (MTS), apoptosis (Caspase 3/7-activity), and gene expression after exposure to titrated doses of citalopram. In vivo analysis for PCNA suggested segregation of effect by location, with the sagittal suture, showing a statistically significant increase in proliferative response. The coronal suture was not similarly affected, however there was a decrease in apoptotic activity at the dural edge as compared to the periosteal edge. No differences in apoptosis by suture or area due to SSRI exposure were observed. In vitro results suggest citalopram exposure increased proliferation and proliferative gene expression, and decreased apoptosis of the MC3T3-E1 cells. Decreased apoptosis was not confirmed in vivo however, an increase in proliferation without a concomitant increase in apoptosis is still defined as hyperplasia. Thus prenatal SSRI exposure may exert a negative effect on post-natal growth through a hyperplasia effect at the cranial growth sites perhaps

  20. Strength Evaluation and Failure Prediction of Short Carbon Fiber Reinforced Nylon Spur Gears by Finite Element Modeling

    NASA Astrophysics Data System (ADS)

    Hu, Zhong; Hossan, Mohammad Robiul

    2013-06-01

    In this paper, short carbon fiber reinforced nylon spur gear pairs, and steel and unreinforced nylon spur gear pairs have been selected for study and comparison. A 3D finite element model was developed to simulate the multi-axial stress-strain behaviors of the gear tooth. Failure prediction has been conducted based on the different failure criteria, including Tsai-Wu criterion. The tooth roots, where has stress concentration and the potential for failure, have been carefully investigated. The modeling results show that the short carbon fiber reinforced nylon gear fabricated by properly controlled injection molding processes can provide higher strength and better performance.

  1. Assessment of the role of sutures in a lizard skull: a computer modelling study

    PubMed Central

    Moazen, Mehran; Curtis, Neil; O'Higgins, Paul; Jones, Marc E.H; Evans, Susan E; Fagan, Michael J

    2008-01-01

    Sutures form an integral part of the functioning skull, but their role has long been debated among vertebrate morphologists and palaeontologists. Furthermore, the relationship between typical skull sutures, and those involved in cranial kinesis, is poorly understood. In a series of computational modelling studies, complex loading conditions obtained through multibody dynamics analysis were imposed on a finite element model of the skull of Uromastyx hardwickii, an akinetic herbivorous lizard. A finite element analysis (FEA) of a skull with no sutures revealed higher patterns of strain in regions where cranial sutures are located in the skull. From these findings, FEAs were performed on skulls with sutures (individual and groups of sutures) to investigate their role and function more thoroughly. Our results showed that individual sutures relieved strain locally, but only at the expense of elevated strain in other regions of the skull. These findings provide an insight into the behaviour of sutures and show how they are adapted to work together to distribute strain around the skull. Premature fusion of one suture could therefore lead to increased abnormal loading on other regions of the skull causing irregular bone growth and deformities. This detailed investigation also revealed that the frontal–parietal suture of the Uromastyx skull played a substantial role in relieving strain compared with the other sutures. This raises questions about the original role of mesokinesis in squamate evolution. PMID:18765341

  2. Cranial sutures work collectively to distribute strain throughout the reptile skull.

    PubMed

    Curtis, Neil; Jones, M E H; Evans, S E; O'Higgins, P; Fagan, M J

    2013-09-01

    The skull is composed of many bones that come together at sutures. These sutures are important sites of growth, and as growth ceases some become fused while others remain patent. Their mechanical behaviour and how they interact with changing form and loadings to ensure balanced craniofacial development is still poorly understood. Early suture fusion often leads to disfiguring syndromes, thus is it imperative that we understand the function of sutures more clearly. By applying advanced engineering modelling techniques, we reveal for the first time that patent sutures generate a more widely distributed, high level of strain throughout the reptile skull. Without patent sutures, large regions of the skull are only subjected to infrequent low-level strains that could weaken the bone and result in abnormal development. Sutures are therefore not only sites of bone growth, but could also be essential for the modulation of strains necessary for normal growth and development in reptiles. PMID:23804444

  3. Cranial sutures work collectively to distribute strain throughout the reptile skull

    PubMed Central

    Curtis, Neil; Jones, M. E. H.; Evans, S. E.; O'Higgins, P.; Fagan, M. J.

    2013-01-01

    The skull is composed of many bones that come together at sutures. These sutures are important sites of growth, and as growth ceases some become fused while others remain patent. Their mechanical behaviour and how they interact with changing form and loadings to ensure balanced craniofacial development is still poorly understood. Early suture fusion often leads to disfiguring syndromes, thus is it imperative that we understand the function of sutures more clearly. By applying advanced engineering modelling techniques, we reveal for the first time that patent sutures generate a more widely distributed, high level of strain throughout the reptile skull. Without patent sutures, large regions of the skull are only subjected to infrequent low-level strains that could weaken the bone and result in abnormal development. Sutures are therefore not only sites of bone growth, but could also be essential for the modulation of strains necessary for normal growth and development in reptiles. PMID:23804444

  4. Theoretical and actual performance of a long duration superpressure balloon made from a biaxially oriented nylon-6-film

    NASA Astrophysics Data System (ADS)

    Lew, T.; Seely, L.; Rai, R.

    1994-02-01

    This paper summarizes the information gained during Winzen's program to develop a practical long duration superpressure balloon capable of carrying a 22.7 kilogram payload at 36.6 kilometers for a over a year. The material used for this Superpressure Stratospheric Vehicle (SSV) is biaxially oriented nylon-6. An allowable design stress as a function of temperature has been developed. A cold temperature creep model for the nylon-6 has been developed. Permeability of nylon-6 to helium has been measured and the results indicate that this material is an excellent gas barrier, especially at cold temperatures. The transmissivity and reflectivity of this biaxially oriented nylon-6 has also been measured. A balloon prototype made with a pressure sensitive adhesive tape has been fabricated and successfully flown.

  5. Isolation and recovery of cellulose from waste nylon/cotton blended fabrics by 1-allyl-3-methylimidazolium chloride.

    PubMed

    Lv, Fangbing; Wang, Chaoxia; Zhu, Ping; Zhang, Chuanjie

    2015-06-01

    Development of a simple process for separating cellulose and nylon 6 from their blended fabrics is indispensable for recycling of waste mixed fabrics. An efficient procedure of dissolution of the fabrics in an ionic liquid 1-allyl-3-methylimidazolium chloride ([AMIM]Cl) and subsequent filtration separation has been demonstrated. Effects of treatment temperature, time and waste fabrics ratio on the recovery rates were investigated. SEM images showed that the cotton cellulose dissolved in [AMIM]Cl while the nylon 6 fibers remained. The FTIR spectrum of regenerated cellulose (RC) was similar with that of virgin cotton fibers, which verified that no other chemical reaction occurred besides breakage of hydrogen bonds during the processes of dissolution and separation. TGA curves indicated that the regenerated cellulose possessed a reduced thermal stability and was effectively removed from waste nylon/cotton blended fabrics (WNCFs). WNCFs were sufficiently reclaimed with high recovery rate of both regenerated cellulose films and nylon 6 fibers. PMID:25843876

  6. Evaluation of anaerobic degradation, biogas and digestate production of cereal silages using nylon-bags.

    PubMed

    Negri, Marco; Bacenetti, Jacopo; Fiala, Marco; Bocchi, Stefano

    2016-06-01

    In this study, the degradation efficiency and the biogas and digestate production during anaerobic digestion were evaluated for the cereal silages most used to feed biogas plants. To this purpose, silages of: maize from the whole plant, maize from the ear, triticale and wheat were digested, inside of nylon bags, in laboratory scale digesters, for 75days. Overall, the test involved 288 nylon bags. After 75days of digestion, the maize ear silage shows the highest degradation efficiency (about 98%) while wheat silage the lowest (about 83%). The biogas production ranges from 438 to 852Nm(3)/t of dry matter for wheat and ear maize silage, respectively. For all the cereal silages, the degradation as well as the biogas production are faster at the beginning of the digestion time. Digestate mass, expressed as percentage of the fresh matter, ranges from 38% to 84% for wheat and maize ear silage, respectively. PMID:26946439

  7. Elution of human granulocytes from nylon fibers by means of repulsive van der Waals forces.

    PubMed

    Absolom, D R; van Oss, C J; Neumann, A W

    1981-01-01

    A novel method for the isolation of granulocytes from nylon fibers is described. It is modification of filtration leukapheresis based on cellular surface thermodynamics. The system takes into account both electrical and van der Waals forces. The elution buffer contains a chelating agent and a surface active agent which lowers the surface tension of the liquid to a value intermediate between that of the surface tensions of the nylon fibers and of the granulocytes. Thus, the attractive van der Waals interaction between the fibers and the granulocytes becomes a repulsion. This results in a two- to threefold increase in cell yield. Phagocytosis, candicidal activity, and oxygen consumption did not appear to be affected through the isolation procedure. By both light and transmission electron microscopy the isolated granulocytes appeared to be morphologically intact. PMID:7314214

  8. Enhancement of strength and stiffness of Nylon 6 filaments through carbon nanotubes reinforcement

    NASA Astrophysics Data System (ADS)

    Mahfuz, Hassan; Adnan, Ashfaq; Rangari, Vijay K.; Hasan, Mohammad M.; Jeelani, Shaik; Wright, Wendelin J.; DeTeresa, Steven J.

    2006-02-01

    We report a method to fabricate carbon nanotube reinforced Nylon filaments through an extrusion process. In this process, Nylon 6 and multiwalled carbon nanotubes (MWCNT) are first dry mixed and then extruded in the form of continuous filaments by a single screw extrusion method. Thermo gravimetric analysis (TGA) and differential scanning calorimetry (DSC) studies have indicated that there is a moderate increase in Tg without a discernible shift in the melting endotherm. Tensile tests on single filaments have demonstrated that Young's modulus and strength of the nanophased filaments have increased by 220% and 164%, respectively with the addition of only 1wt.% MWCNTs. SEM studies and micromechanics based calculations have shown that the alignment of MWCNTs in the filaments, and high interfacial shear strength between the matrix and the nanotube reinforcement was responsible for such a dramatic improvement in properties.

  9. Methods for gene expression profiling in dermatology research using DermArray nylon filter DNA microarrays.

    PubMed

    Davis, Richard L; DuBreuil, Rusla M; Reddy, Shanker P; Dooley, Thomas P

    2005-01-01

    Here we present methods of gene expression profiling using nylon filter deoxyribonucleic acid (DNA) microarrays and radiolabeled and nonradiolabeled hybridization probes. DermArray(R) nylon filter DNA microarrays were designed specifically for use in dermatology research. A patent-pending method was used to select approx 4400 highly informative, sequence-verified human cDNA clones for this DNA micro array. Using DermArray(R) filters, biomarkers have been discovered for normal and pathologic cells from skin, and for responses to dermatologic drugs. As an example, gene expression profiling was performed with hydroquinone-treated SKMel-28 cells, a melanoma cell line. Also included are the methods for bioinformatic analysis using Pathwaystrade mark software. PMID:15502201

  10. Layered conductive polymer on nylon membrane templates for high performance, thin-film supercapacitor electrodes

    NASA Astrophysics Data System (ADS)

    Shi, HaoTian Harvey; Naguib, Hani E.

    2016-04-01

    Flexible Thin-film Electrochemical Capacitors (ECs) are emerging technology that plays an important role as energy supply for various electronics system for both present era and the future. Intrinsically conductive polymers (ICPs) are promising pseudo-capacitive materials as they feature both good electrical conductivity and high specific capacitance. This study focuses on the construction and characterization of ultra-high surface area porous electrodes based on coating of nano-sized conductive polymer materials on nylon membrane templates. Herein, a novel nano-engineered electrode material based on nylon membranes was presented, which allows the creation of super-capacitor devices that is capable of delivering competitive performance, while maintaining desirable mechanical characteristics. With the formation of a highly conductive network with the polyaniline nano-layer, the electrical conductivity was also increased dramatically to facilitate the charge transfer process. Cyclic voltammetry and specific capacitance results showed promising application of this type of composite materials for future smart textile applications.

  11. Effect of antiarrhythmic drugs on In-111-labeled leukocytes: chemotaxis and adherence to nylon wool

    SciTech Connect

    Thakur, M.L.; Walsh, L.J.; Zaret, B.L.; Gottschalk, A.

    1982-02-01

    The influence of lidocaine (L) and procainamide (P) on the chemotactic ability and adherence to nylon wool of In-111-labeled human polymorphonuclear leukocytes (PMNs) was investigated. At the normal therapeutic levels of L (0.022 mM whole blood) or P (0.03 mM whole blood) no change in PMN function was observed. However, at and above five times the aforementioned blood levels of L, significant reduction in the chemotactic ability of PMNs was noted (p less than 0.005). The adverse effects of In-111 radiation appeared insignificant at all L or P concentrations during the 3-hr observation period. The labeled PMNs were resistant to the toxic effects of a higher concentration of P than that of L, and the reduction in PMN chemotaxis and adherence to nylon wool was not apparent until the P concentration reached 1.5 mM.

  12. [Nerve anastomoses. Sutures or fibrinogenic glue? Preliminary results].

    PubMed

    Boedts, D; Bouckaert, J I

    1984-01-01

    A comparative animal experiment was set up between two nerve anastomosis techniques, one by sealing nerve ends with a fibrinogen-thrombine glue and the other by classical perineural suturing. It was concluded that glueing nerve ends, from the surgical-technical point of view is a better method than suturing. It is an easy, time-sparing method which allows excellent coaptation of the severed nerves with minimal iatrogenic trauma. On the long run however some questions remain. There is the problem of induced fibrosis by using high doses of aprotinine and factor XIII at the site of the nerve junctions and on the other hand the influence of fibrinolysis in traumatized tissues, with early decrease of tensile strength at the junctions before nerve healing. So glued nerve ends should be completely free of tension, protected against secondary shearing forces, and also immobilization of the region is required. PMID:6385609

  13. Meniscal suture. An experimental study in the dog.

    PubMed

    Kawai, Y; Fukubayashi, T; Nishino, J

    1989-06-01

    A longitudinal tear was made and then sutured in the peripheral quarter of the medial meniscus of 43 dogs. The sutured menisci were examined using histologic and microangiographic techniques at regular intervals during a 12-week period. Biomechanical tests were also performed. The healing process was promoted not only by the synovial blood supply but also by the peripheral blood supply. Even at the end of 12 weeks, the healing tissue was mainly composed of fibrous tissue, but chondrocytelike cells were also found. The tensile forces were calculated and compared with the opposite leg. The maximum tensile strength reached 80% of that of the opposite side at the end of the 12-week period. PMID:2656029

  14. Bridging Suture Repair for Acetabular Chondral Carpet Delamination

    PubMed Central

    Kaya, Mitsunori; Hirose, Toshiaki; Yamashita, Toshihiko

    2015-01-01

    Acetabular chondral carpet delamination is a frequent finding at hip arthroscopy. The cartilage is macroscopically normal but deboned from the subchondral bone, without a disruption at the chondrolabral junction. Arthroscopic anatomic repair of delaminated cartilage is challenging. We propose that a combination of microfracture and use of stitches to press the delaminated cartilage against the subchondral bone using a suture limb offers an effective method to provide an environment for cartilage repair. This article describes the technique of bridging suture repair for carpet delamination in detail; the technique enables the surgeon to stabilize the delaminated acetabular cartilage. Intra-articular soft anchors and an acetabular rim knotless anchor footprint provide a stable repair for delaminated cartilage. This technique is especially helpful in cases with acetabular cartilage carpet delamination. PMID:26759774

  15. A Complication in Hypospadias Surgery Due to Anchoring Suture

    PubMed Central

    Gollu, Gulnur; Kucuk, Gonul; Karabulut, Ayse Anıl; Yagmurlu, Aydin; Cakmak, Murat

    2015-01-01

    The complication rates are still 1–90% both in proximal and distal hypospadias regardless of the surgeon’s experience and the usage of most developed techniques. The literature survey revealed few complications of glans penis including meatal stenosis, prolapsus and retraction. Despite our literature survey, we could not find any article concerning the permanent scar tissue at the dorsal part of glans following hypospadias surgeries. A new complication can be added to these, concerning glans which is the formation of postoperative scar tissue as a reaction to suture material used in traction, stent anchoring or both. The aim of this paper is to demonstrate four cases which had glanular scar due to traction suture following the surgical procedures for hypospadias repair. PMID:26180503

  16. The influence of temperature on the sorption of benzocaine by nylon 6 from aqueous cosolvents.

    PubMed

    Richardson, N E; Meakin, B J

    1977-02-01

    The influence of temperature on the sorption of benzocaine by nylon 6 powder from aqueous cosolvents has been assessed. At about 30 degrees discontinuities appear in the Van't Hoff plots for sorption from water and aqueous PEG 400, which may be attributed to transitional changes in the polymer structure. No such discontinuities are apparent for sorption from aqueous ethanol over the temperature range 15-60 degrees, which is indicative of plasticizaton by this cosolvent. PMID:15070

  17. Measuring tropospheric HNO sub 3 : Problems and prospects for nylon filter and mist chamber techniques

    SciTech Connect

    Talbot, R.W.; Vijgen, A.S.; Harriss, R.C. )

    1990-05-20

    The authors performed a series of laboratory and field measurements to evaluate the mist chamber technique for determining tropospheric HNO{sub 3} concentrations. Both the mist chamber and standard Nylon filter techniques exhibit high collection efficiency and excellent agreement measuring HNO{sub 3} vapors from a permeation source. When simultaneously sampling ambient air in eastern Virginia the Nylon filter measured an average of 70% higher HNO{sub 3} concentration than the mist chamber technique. Results indicate that O{sub 3} causes a low-level positive artifact interference in HNO{sub 3} measurements performed with the filter technique. This O{sub 3}-induced error is small, however, compared to the large difference between atmospheric HNO{sub 3} concentrations determined with the two techniques. The authors hypothesize that unidentified (organic ) nitrogen species in the atmosphere react for form NO{sub 3}{sup {minus}} on the filter and this phenomenon may interfere with Nylon filter measurements of HNO{sub 3} vapor. These potential interferences did not appear to affect measurements of HNO{sub 3} with the mist chamber method, but they are continuing studies to evaluate potential interference from various atmospheric species. Because the mist chamber technique employs an aerosol prefilter, it is probably best suited for measuring HNO{sub 3} concentrations when particle-NO{sub 3}{sup {minus}} levels are low. In light of the preliminary results, the authors caution users of the Nylon filter method to continue to critically evaluate this technique for specificity in determining HNO{sub 3} vapor phase concentrations in the atmosphere, particularly at low concentrations typical of the remote troposphere.

  18. Screening nylon-3 polymers, a new class of cationic amphiphiles, for siRNA delivery.

    PubMed

    Nadithe, Venkatareddy; Liu, Runhui; Killinger, Bryan A; Movassaghian, Sara; Kim, Na Hyung; Moszczynska, Anna B; Masters, Kristyn S; Gellman, Samuel H; Merkel, Olivia M

    2015-02-01

    Amphiphilic nucleic acid carriers have attracted strong interest. Three groups of nylon-3 copolymers (poly-β-peptides) possessing different cationic/hydrophobic content were evaluated as siRNA delivery agents in this study. Their ability to condense siRNA was determined in SYBR Gold assays. Their cytotoxicity was tested by MTT assays, their efficiency of delivering Alexa Fluor-488-labeled siRNA intracellularly in the presence and absence of uptake inhibitors was assessed by flow cytometry, and their transfection efficacies were studied by luciferase knockdown in a cell line stably expressing luciferase (H1299/Luc). Endosomal release was determined by confocal laser scanning microscopy and colocalization with lysotracker. All polymers efficiently condensed siRNA at nitrogen-to-phosphate (N/P) ratios of 5 or lower, as reflected in hydrodynamic diameters smaller than that at N/P 1. Although several formulations had negative zeta potentials at N/P 1, G2C and G2D polyplexes yielded >80% uptake in H1299/Luc cells, as determined by flow cytometry. Luciferase knockdown (20-65%) was observed after transfection with polyplexes made of the high molecular weight polymers that were the most hydrophobic. The ability of nylon-3 polymers to deliver siRNA intracellularly even at negative zeta potential implies that they mediate transport across cell membranes based on their amphiphilicity. The cellular uptake route was determined to strongly depend on the presence of cholesterol in the cell membrane. These polymers are, therefore, very promising for siRNA delivery at reduced surface charge and toxicity. Our study identified nylon-3 formulations at low N/P ratios for effective gene knockdown, indicating that nylon-3 polymers are a new, promising type of gene delivery agent. PMID:25437915

  19. Supersonically blown nylon-6 nanofibers entangled with graphene flakes for water purification

    NASA Astrophysics Data System (ADS)

    Lee, Jong-Gun; Kim, Do-Yeon; Mali, Mukund G.; Al-Deyab, Salem S.; Swihart, Mark T.; Yoon, Sam S.

    2015-11-01

    Water purification membranes, capable of purifying a few to tens of milliliters of aqueous methylene blue solution in a minute, were produced by supersonically blowing graphene flakes with a nylon-6 polymeric solution. The solution-blown nylon-6 nanofibers became entangled with graphene flakes thereby locking the graphene flakes within the frame of the bendable two-dimensional film structure. This method, which yielded a 5 × 7 cm2-sized membrane in less than 10 seconds, is commercially viable owing to fast fabrication and scalability. We show that our water purification device allows a flow rate range of 0.3-4 L h-1 with a membrane area of just 5 cm2, under a pressure difference of 0.5-3.5 bar. If the membrane were scaled up to 0.5 m2, it could provide 300-4000 L h-1 flow rate, an ample supply for home use.Water purification membranes, capable of purifying a few to tens of milliliters of aqueous methylene blue solution in a minute, were produced by supersonically blowing graphene flakes with a nylon-6 polymeric solution. The solution-blown nylon-6 nanofibers became entangled with graphene flakes thereby locking the graphene flakes within the frame of the bendable two-dimensional film structure. This method, which yielded a 5 × 7 cm2-sized membrane in less than 10 seconds, is commercially viable owing to fast fabrication and scalability. We show that our water purification device allows a flow rate range of 0.3-4 L h-1 with a membrane area of just 5 cm2, under a pressure difference of 0.5-3.5 bar. If the membrane were scaled up to 0.5 m2, it could provide 300-4000 L h-1 flow rate, an ample supply for home use. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr06549f

  20. Screening Nylon-3 Polymers, a New Class of Cationic Amphiphiles, for siRNA Delivery

    PubMed Central

    2015-01-01

    Amphiphilic nucleic acid carriers have attracted strong interest. Three groups of nylon-3 copolymers (poly-β-peptides) possessing different cationic/hydrophobic content were evaluated as siRNA delivery agents in this study. Their ability to condense siRNA was determined in SYBR Gold assays. Their cytotoxicity was tested by MTT assays, their efficiency of delivering Alexa Fluor-488-labeled siRNA intracellularly in the presence and absence of uptake inhibitors was assessed by flow cytometry, and their transfection efficacies were studied by luciferase knockdown in a cell line stably expressing luciferase (H1299/Luc). Endosomal release was determined by confocal laser scanning microscopy and colocalization with lysotracker. All polymers efficiently condensed siRNA at nitrogen-to-phosphate (N/P) ratios of 5 or lower, as reflected in hydrodynamic diameters smaller than that at N/P 1. Although several formulations had negative zeta potentials at N/P 1, G2C and G2D polyplexes yielded >80% uptake in H1299/Luc cells, as determined by flow cytometry. Luciferase knockdown (20–65%) was observed after transfection with polyplexes made of the high molecular weight polymers that were the most hydrophobic. The ability of nylon-3 polymers to deliver siRNA intracellularly even at negative zeta potential implies that they mediate transport across cell membranes based on their amphiphilicity. The cellular uptake route was determined to strongly depend on the presence of cholesterol in the cell membrane. These polymers are, therefore, very promising for siRNA delivery at reduced surface charge and toxicity. Our study identified nylon-3 formulations at low N/P ratios for effective gene knockdown, indicating that nylon-3 polymers are a new, promising type of gene delivery agent. PMID:25437915

  1. Chemisorption of estrone in nylon microfiltration membranes: Adsorption mechanism and potential use for estrone removal from water.

    PubMed

    Han, Jie; Qiu, Wei; Hu, Jiangyong; Gao, Wei

    2012-03-01

    Estrone is a representative steroid estrogen contaminant that has been detected in effluents from sewage treatment facilities, as well as in surface and ground waters. Our study shows that estrone can be readily removed from water via a unique chemisorption mechanism using nylon microfiltration membranes. Experiments on a laboratory in-line filtration system showed instant removal of estrone from 200 μg/l aqueous solutions by 0.45-μm nylon membranes (ca. 35 L per m(2) membrane). Comparisons with 0.45-μm PVDF, PTFE and glass microfiber membranes suggested that the significant estrone adsorption in nylon membrane should be predominately driven by a different mechanism rather than common physical adsorption. Fourier transform infrared spectroscopy study on nylon membranes and a model compound, N-methylacetamide, showed that the significant adsorption originated from the hydrogen bonding between terminal -OH groups on estrone molecules and nucleophile -C=O groups in amide groups of nylon 6,6. The saturated nylon membrane showed very low leachability in ambient water, while it could be effectively regenerated in alkaline or ethanol solutions. Preliminary reusability study showed that the membrane maintained a consistent adsorption capacity for estrone during ten cycles of reuse. The chemisorption-based polymeric adsorption may provide a new alternative approach for removing estrone and potentially other trace organic contaminants from water. PMID:22189293

  2. The absence of CO/sub 2/ in nylon-4 prepared with KOH + radioactive CO/sub 2/ catalyst

    SciTech Connect

    Bacskai, R.; Fries, B.A.

    1982-08-01

    This report describes the polymerization of 2-pyrrolidone with KOH + radioactive CO/sub 2/ catalyst and the radioactive assay of the polymer, aimed to detect CO/sub 2/ incorporation in nylon-4. Some possible mechanisms for the role of CO/sub 2/ in producing nylon-4 are suggested. Comparative evaluations are made with the mechanisms of CO/sub 2/ incorporation in nylon-7 presented in other reports. The results show that water washing removes most of the radioactivity from the polymer. The molecular weight of the polymer is 228,000; it was found that the polymer contained only about 1 CO/sub 2//100 polymer molecule. Thus, it can be concluded that CO/sub 2/ is not incorporated to any significant degree into nylon-4, and the small radioactivity is probably caused by traces of residual CO/sub 2/ catalyst. The absence of CO/sub 2/ in anionic nylon-4 is in sharp contrast with the reported high CO/sub 2/ content in anionic nylon-7.

  3. Measuring tropospheric HNO3 - Problems and prospects for Nylon filter and mist chamber techniques

    NASA Astrophysics Data System (ADS)

    Talbot, R. W.; Vijgen, A. S.; Harriss, R. C.

    1990-05-01

    A series of laboratory and field measurements was performed to evaluate the mist chamber technique for determining tropospheric HNO3 concentrations. Both the mist chamber and standard Nylon filter techniques exhibit high collection efficiency and excellent agreement measuring HNO3 vapors from a permeation source. When simultaneously sampling ambient air in eastern Virginia, the Nylon filter measured an average of 70 percent higher HNO3 concentration than the mist chamber technique. The results indicate that O3 causes a low-level positive artifact interference in HNO3 measurements performed with the filter technique. This O3-induced error is small, however, compared to the large difference between atmospheric HNO3 concentrations determined with the two techniques. It is hypothesized that unidentified (organic?) nitrogen species in the atmosphere react for form NO3(-) on the filter and this phenomenon may interfere with Nylon filter measurements of HNO3 vapor. These potential interferences did not appear to affect measurements of HNO3 with the mist chamber method.

  4. Continuous electrospinning of polymer nanofibers of Nylon-6 using an atomic force microscope tip.

    PubMed

    Gururajan, Giriprasath; Sullivan, S P; Beebe, T P; Chase, D B; Rabolt, J F

    2011-08-01

    An atomic force microscopy (AFM) probe is successfully utilized as an electrospinning tip for fabricating Nylon-6 nanofibers. The nanometre-size tip enabled controlled deposition of uniform polymeric nanofibers within a 1 cm diameter area. Nylon-6 nanofibers were continuously electrospun at a solution concentration as low as 1 wt% Nylon-6 in 1,1,1,3,3,3-hexafluoro-2-propanol (HFIP). Wide-angle X-ray diffraction (WAXD) and differential scanning calorimetry (DSC) results of the AFM electrospun fibers indicated that the nanofibers predominantly display the meta-stable γ crystalline form suggesting rapid crystallization rate during the process. In addition to precise control over fiber deposition and diameter, some of the drawbacks of conventional electrospinning such as large volume of solutions and clogging of needles can be overcome using this AFM based electrospinning technique. Lastly, a comparison of electrospun fibers from syringe-needle based electrospinning and AFM probe-tip based electrospinning indicated significant morphological and microstructural differences in the case of AFM based electrospinning. PMID:21713288

  5. Investigation on Dry Sliding Wear Behavior of Nylon66/GnP Nano-composite

    NASA Astrophysics Data System (ADS)

    Sankara Narayana, Kota; Suman, Koka Naga Sai; Arun Vikram, Kothapalli

    2016-06-01

    The tribological behavior of graphene nano platelets (GnP) reinforced Nylon66 polymer Nano composites were studied using a pin-on-disc apparatus under dry sliding conditions. The influence of wear control factors like applied load, velocity, sliding distance and weight percentage of GnP reinforcement on the responses like specific wear rate and frictional coefficient were investigated. Nano composites were developed by melt mixing of various weight fractions of GnP (0/0.5/1/2) with nylon 66 using twin screw extruder. A design of experiments based on the Taguchi technique was performed to acquire data in a controlled way and was successfully used to identify the optimal combinations of control factors influencing the outputs. Analysis of variance was employed to investigate the influence and contribution of control factors on the responses. The results showed that the inclusion of GnP as reinforcing material in Nylon66 Nano composites, decreases the friction coefficient and increases the wear resistance of the Nano composites significantly.

  6. Modification of nylon-6 with semi-rigid poly (p-diphenyl oxide terephthalamide)

    SciTech Connect

    Lin, M.F.; Wang, H.H.; Shu, Y.C.

    1994-03-01

    In this study, the flexible nylon-6 was reinforced by the semi-rigid aromatic polyamide, poly (p-diphenyl oxide terephthalamide) (POA), through physical polybending and chemical copolymerization using p-aminophenylacetic acid (P-APA) as a coupling agent. From the DSC measurements, it was shown that Tg of the polyblends was increased with the increase of POA content. The Tg and Tm of multiblock copolyamides were found to be higher than those of polyblends and triblock copolyamides. From the Rheovibron measurements, it was shown that the POA with nylon-6 poy-blends exhibited higher E{prime} and Tg value than that of nylon-6, which increased with the increase of POA content. The Tg and E{prime} values of multiblock copolyamides were higher than those of polyblends triblock copolyamides. Scanning electron microscopy revealed that the polyblends were a dispersed phase structure, although the multiblock copolyamides exhibited a homogeneous texture rather than an aggregated one. From the wide-angle x-ray diffraction pattern, the triblock copolyamides and polyblends had two diffraction peaks, i.e., 2 {theta} = 20.5{degrees} and 24{degrees}. However, the multiblock had only one at 2 {theta} = 20{degrees}, which indicates that a different crystal structure of multiblock copolyamides. For the mechanical properties, it was found that the multiblock copolyamides had a more significant reinforcing effect than those of polyblends and triblock copolyamides. 21 refs., 11 figs., 5 tabs.

  7. Measuring tropospheric HNO3 - Problems and prospects for Nylon filter and mist chamber techniques

    NASA Technical Reports Server (NTRS)

    Talbot, R. W.; Vijgen, A. S.; Harriss, R. C.

    1990-01-01

    A series of laboratory and field measurements was performed to evaluate the mist chamber technique for determining tropospheric HNO3 concentrations. Both the mist chamber and standard Nylon filter techniques exhibit high collection efficiency and excellent agreement measuring HNO3 vapors from a permeation source. When simultaneously sampling ambient air in eastern Virginia, the Nylon filter measured an average of 70 percent higher HNO3 concentration than the mist chamber technique. The results indicate that O3 causes a low-level positive artifact interference in HNO3 measurements performed with the filter technique. This O3-induced error is small, however, compared to the large difference between atmospheric HNO3 concentrations determined with the two techniques. It is hypothesized that unidentified (organic?) nitrogen species in the atmosphere react for form NO3(-) on the filter and this phenomenon may interfere with Nylon filter measurements of HNO3 vapor. These potential interferences did not appear to affect measurements of HNO3 with the mist chamber method.

  8. Variable stiffness and recruitment using nylon actuators arranged in a pennate configuration

    NASA Astrophysics Data System (ADS)

    Kianzad, Soheil; Pandit, Milind; Lewis, Johnathan D.; Berlingeri, Alexander R.; Haebler, Karl J.; Madden, John D. W.

    2015-04-01

    In muscle variable impedance and ability to recruit fibers as needed helps enable actions such as walking and catching. A new biomimetic structure of nylon actuator is presented that imitates the human pennate muscle in structure, ability to vary stiffness and the ability to increase force by recruiting additional fibers. The actuator consists of 16 silver coated nylon coiled fibers attached to a central tendon at an angle of 20°. Each nylon coil produces 20 MPa of stress at constant length and nearly 20% strain at fixed load. Fibers are individually switched ON and OFF using transistors so that each element can be recruited, and the stiffness varied. The amount of input power is controlled with pulse width modulation (PWM) techniques. It is observed that the spring constant of the pennate structure varies from that of its passive state, 503 N/m and a resonance frequency of 1.4 Hz, to 1480 N/m with resonance frequency of 3.1 Hz in the active state where all the fibers are switched on under a 25 N load. Stiffness can be varied by a factor of 9.

  9. Knotless Arthroscopic Repair of Subscapularis Tendon Tears Using Looped Suture.

    PubMed

    Gilmer, Brian B; Crall, Timothy S; Guttmann, Dan

    2015-06-01

    Subscapularis tendon tears present a technical challenge because both diagnosis and arthroscopic treatment can be difficult. One difficulty is the limited visualization and working space of the anterior shoulder. Although most tears of the subscapularis are partial- or full-thickness tears of the upper third of the tendon, occasionally, larger or more retracted tears are encountered. Various techniques have been developed to treat a wide variety of tear patterns. We present a simple technique using a looped suture that remains easy to use in the limited working space of the anterior shoulder; can be easily modified to accommodate a broad spectrum of subscapularis pathology, from partial to full and retracted tears; and uses familiar viewing and working portals. This technique creates a single-row, knotless repair. Traction on the superior suture improves visualization and ease of passing more inferior sutures. Risks include unintentional over-tensioning of the repair and medialization of the femoral footprint, which can be avoided with appropriate exposure and arm positioning during repair. Postoperative care includes restriction of external rotation for 3 to 6 weeks and strengthening at 3 months. PMID:26258042

  10. Knotless Arthroscopic Repair of Subscapularis Tendon Tears Using Looped Suture

    PubMed Central

    Gilmer, Brian B.; Crall, Timothy S.; Guttmann, Dan

    2015-01-01

    Subscapularis tendon tears present a technical challenge because both diagnosis and arthroscopic treatment can be difficult. One difficulty is the limited visualization and working space of the anterior shoulder. Although most tears of the subscapularis are partial- or full-thickness tears of the upper third of the tendon, occasionally, larger or more retracted tears are encountered. Various techniques have been developed to treat a wide variety of tear patterns. We present a simple technique using a looped suture that remains easy to use in the limited working space of the anterior shoulder; can be easily modified to accommodate a broad spectrum of subscapularis pathology, from partial to full and retracted tears; and uses familiar viewing and working portals. This technique creates a single-row, knotless repair. Traction on the superior suture improves visualization and ease of passing more inferior sutures. Risks include unintentional over-tensioning of the repair and medialization of the femoral footprint, which can be avoided with appropriate exposure and arm positioning during repair. Postoperative care includes restriction of external rotation for 3 to 6 weeks and strengthening at 3 months. PMID:26258042

  11. Healing of the goat anterior cruciate ligament after a new suture repair technique and bioscaffold treatment.

    PubMed

    Nguyen, D Tan; Geel, Jurre; Schulze, Martin; Raschke, Michael J; Woo, Savio L-Y; van Dijk, C Niek; Blankevoort, Leendert

    2013-10-01

    Primary suture repair of the anterior cruciate ligament (ACL) has been used clinically in an attempt to heal the ruptured ACL. The results, however, were not satisfactory, which in retrospect can be attributed to the used suturing technique and the suboptimal healing conditions. These constraining conditions can be improved by introducing a new suturing technique and by using small intestinal submucosa (SIS) as a bioscaffold. It is hypothesized that the suturing technique keep the torn ends together and that SIS enhance and promote the healing of the ACL. The goat was used as the study model. In the Suture group, the left ACL was transected and suture repaired with a new locking suture repair technique (n=5) allowing approximation and fixation under tension. The Suture-SIS group underwent the same procedure with the addition of SIS (n=5). The right ACL served as control. After 12 weeks of healing, anterior-posterior translation and in situ force of the healing ACL were measured, followed by the measurement of the cross-sectional area and structural stiffness. Routine histology was performed on tissue samples. Gross morphology showed that the healing ACL was continuous with collagenous tissue in both groups. The cross-sectional area of the Suture and the Suture-SIS group was 35% and 50% of the intact control, respectively. The anterior-posterior translations at different flexion angles were statistically not different between the Suture group and the Suture-SIS group. Only the in situ force at 30° in the Suture-SIS group was higher than in the Suture group. Tensile tests showed that the stiffness for the Suture group was not different from the Suture-SIS group (31.1±8.1 N/mm vs. 41.9±18.0 N/mm [p>0.05]). Histology showed longitudinally aligned collagen fibers from origo to insertion. More fibroblasts were present in the healing tissue than in the control intact tissue. The study demonstrated the proof of concept of ACL repair in a goat model with a new suture

  12. Vapor-liquid equilibria for the systems difluoromethane + chlorodifluoromethane, difluoromethane + dichlorodifluoromethane, and difluoromethane + chloromethane at 10.0 C

    SciTech Connect

    Kang, Y.W.; Chung, K.Y.

    1996-05-01

    Isothermal vapor-liquid equilibria for the three binary systems (difluoromethane + chlorodifluoromethane, difluoromethane + dichlorodifluoromethane, and difluoromethane + chloromethane) have been measured at 10.0 C. The experimental data for the binary systems are correlated with the Wilson equation and the relevant parameters are presented. The difluoromethane + dichlorodifluoromethane system forms a minimum boiling azeotrope, but the others do not.

  13. Ultrastructure, histochemistry, and mineralization patterns in the ecdysial suture of the blue crab, Callinectes sapidus.

    PubMed

    Priester, Carolina; Dillaman, Richard M; Gay, D Mark

    2005-12-01

    The ecdysial suture is the region of the arthropod exoskeleton that splits to allow the animal to emerge during ecdysis. We examined the morphology and composition of the intermolt and premolt suture of the blue crab using light microscopy and scanning electron microscopy. The suture could not be identified by routine histological techniques; however 3 of 22 fluorescein isothiocyanate-labeled lectins tested (Lens culinaris agglutinin, Vicia faba agglutinin, and Pisum sativum agglutinin) differentiated the suture, binding more intensely to the suture exocuticle and less intensely to the suture endocuticle. Back-scattered electron (BSE) and secondary electron observations of fracture surfaces of intermolt cuticle showed less mineralized regions in the wedge-shaped suture as did BSE analysis of premolt and intermolt resin-embedded cuticle. The prism regions of the suture exocuticle were not calcified. X-ray microanalysis of both the endocuticle and exocuticle demonstrated that the suture was less calcified than the surrounding cuticle with significantly lower magnesium and phosphorus concentrations, potentially making its mineral more soluble. The presence or absence of a glycoprotein in the organic matrix, the extent and composition of the mineral deposited, and the thickness of the cuticle all likely contribute to the suture being removed by molting fluid, thereby ensuring successful ecdysis. PMID:17481327

  14. Modification of U-Stitch Laparoscopic Gastrostomy Technique to Minimize Suture Knot Abscess Formation.

    PubMed

    McCagg, Jillian; Markham, Sarah; Idowu, Olajire; Newton, Christopher; Palmer, Barnard; Kim, Sunghoon

    2016-06-01

    Aim U-stitch laparoscopic gastrostomy is a commonly used technique for placement of balloon gastrostomy for pediatric patients. The U-stitch method was modified by others whereby the stay sutures are placed in a subcutaneous tissue. Although this modification has been reported to be superior, it has led to suture knot abscess formation which was not reported in the original method. We developed further modification whereby the stay-suture knots are positioned within the gastrostomy tract instead of the subcutaneous tissue which minimizes suture knot abscess formation. Methods Modified U-stitch technique was used to place the balloon gastrostomy. The U-stitch stay sutures are placed to hold the stomach to the abdominal wall. These sutures are subcutaneously tunneled toward the gastrostomy tract and tied to the opposing sutures with the resulting knots lying within the tract of the gastrostomy. Chart reviews of patients who underwent this modified U-stitch method were done. Results A total of 27 consecutive patients were evaluated. Minimal follow-up period was 6 months. No suture knot abscess complication was found. One patient for whom we used a polyglactin (Vicryl; Ethicon Inc., Cincinnati, Ohio, United States) suture developed cellulitis around the gastrostomy site which cleared with antibiotic. Remaining 10 patients for whom we used Vicryl suture and 16 patients for whom polydioxanone (PDS; Ethicon Inc.) suture was used did not develop any infections. Conclusion Subcutaneous placement of stay suture within the open gastrostomy tract rather than within closed subcutaneous tissue may minimize suture knot abscess formation. PMID:26011076

  15. Bundles of Spider Silk, Braided into Sutures, Resist Basic Cyclic Tests: Potential Use for Flexor Tendon Repair

    PubMed Central

    Hennecke, Kathleen; Redeker, Joern; Kuhbier, Joern W.; Strauss, Sarah; Allmeling, Christina; Kasper, Cornelia; Reimers, Kerstin; Vogt, Peter M.

    2013-01-01

    Repair success for injuries to the flexor tendon in the hand is often limited by the in vivo behaviour of the suture used for repair. Common problems associated with the choice of suture material include increased risk of infection, foreign body reactions, and inappropriate mechanical responses, particularly decreases in mechanical properties over time. Improved suture materials are therefore needed. As high-performance materials with excellent tensile strength, spider silk fibres are an extremely promising candidate for use in surgical sutures. However, the mechanical behaviour of sutures comprised of individual silk fibres braided together has not been thoroughly investigated. In the present study, we characterise the maximum tensile strength, stress, strain, elastic modulus, and fatigue response of silk sutures produced using different braiding methods to investigate the influence of braiding on the tensile properties of the sutures. The mechanical properties of conventional surgical sutures are also characterised to assess whether silk offers any advantages over conventional suture materials. The results demonstrate that braiding single spider silk fibres together produces strong sutures with excellent fatigue behaviour; the braided silk sutures exhibited tensile strengths comparable to those of conventional sutures and no loss of strength over 1000 fatigue cycles. In addition, the braiding technique had a significant influence on the tensile properties of the braided silk sutures. These results suggest that braided spider silk could be suitable for use as sutures in flexor tendon repair, providing similar tensile behaviour and improved fatigue properties compared with conventional suture materials. PMID:23613793

  16. Preparation and properties of banana fiber-reinforced composites based on high density polyethylene (HDPE)/Nylon-6 blends.

    PubMed

    Liu, H; Wu, Q; Zhang, Q

    2009-12-01

    Banana fiber (BaF)-filled composites based on high density polyethylene (HDPE)/Nylon-6 blends were prepared via a two-step extrusion method. Maleic anhydride grafted styrene/ethylene-butylene/styrene triblock polymer (SEBS-g-MA) and maleic anhydride grafted polyethylene (PE-g-MA) were used to enhance impact performance and interfacial bonding between BaF and the resins. Mechanical, crystallization/melting, thermal stability, water absorption, and morphological properties of the composites were investigated. In the presence of SEBS-g-MA, better strengths and moduli were found for HDPE/Nylon-6 based composites compared with corresponding HDPE based composites. At a fixed weight ratio of PE-g-MA to BaF, an increase of BaF loading up to 48.2 wt.% led to a continuous improvement in moduli and flexural strength of final composites, while impact toughness was lowered gradually. Predicted tensile modulus by the Hones-Paul model for three-dimensional random fiber orientation agreed well with experimental data at the BaF loading of 29.3 wt.%. However, the randomly-oriented fiber models underestimated experimental data at higher fiber levels. It was found that the presence of SEBS-g-MA had a positive influence on reinforcing effect of the Nylon-6 component in the composites. Thermal analysis results showed that fractionated crystallization of the Nylon-6 component in the composites was induced by the addition of both SEBS-g-MA and PE-g-MA. Thermal stability of both composite systems differed slightly, except an additional decomposition peak related to the minor Nylon-6 for the composites from the HDPE/Nylon-6 blends. In the presence of SEBS-g-MA, the addition of Nylon-6 and increased BaF loading level led to an increase in the water absorption value of the composites. PMID:19574041

  17. A new technique to improve the mechanical and biological performance of ultra high molecular weight polyethylene using a nylon coating.

    PubMed

    Firouzi, Dariush; Youssef, Aya; Amer, Momen; Srouji, Rami; Amleh, Asma; Foucher, Daniel A; Bougherara, Habiba

    2014-04-01

    A new patent pending technique is proposed in this study to improve the mechanical and biological performance of ultra high molecular weight polyethylene (UHMWPE), i.e., to uniformly coat nylon onto the UHMWPE fiber (Firouzi et al., 2012). Mechanical tests were performed on neat and new nylon coated UHMWPE fibers to examine the tensile strength and creep resistance of the samples at different temperatures. Cytotoxicity and osteolysis induced by wear debris of the materials were investigated using (MTT) assay, and RT-PCR for tumor necrosis factor alpha (TNFα) and interleukin 6 (IL-6) osteolysis markers. Mechanical test results showed substantial improvement in maximum creep time, maximum breaking force, and toughness values of Nylon 6,6 and Nylon 6,12 coated UHMWPE fibers between average 15% and 60% at 25, 50, and 70°C. Furthermore, cytotoxicity studies have demonstrated significant improvement in cell viability using the nylon coated UHMWPE over the neat one (72.4% vs 54.8%) for 48h and (80.7 vs 5%) for 72h (P<0.01). Osteolysis test results have shown that the expression levels of TNFα and IL-6 markers induced by the neat UHMWPE fiber were significantly higher than those induced by the Nylon 6,6 coated UHMWPE (2.5 fold increase for TNFα at 48h, and three fold increase for IL-6 at 72h (P<0.01)). This study suggests that UHMWPE coated with nylon could be used as a novel material in clinical applications with lower cytotoxicity, less wear debris-induced osteolysis, and superior mechanical properties compared to neat UHMWPE. PMID:24487078

  18. Orientation of late Precambrian sutures in the Arabian-Nubian shield

    NASA Astrophysics Data System (ADS)

    Stern, Robert J.; Nielsen, Kent C.; Best, Eric; Sultan, Mohamed; Arvidson, Raymond E.

    1990-11-01

    Recent tectonic models have resulted in conflicting descriptions of how the late Precambrian sutures of the Arabian-Nubian shield extend into northeast Africa. The Hamisana shear zone in northeastern Sudan is critical to this discussion because it truncates and disrupts two sutures, the Allaqi-Heiani and the Onib-Sol Hamed. Analysis of field structural data, Thematic Mapper imagery, and Rb-Sr and U-Pb geochronology suggests that the Allaqi-Heiani suture is the western extension of the Onib-Sol Hamed suture and that both make up the exposed parts of a far-traveled, polydeformed ophiolitic nappe complex. Subsequent deformation localized in the Hamisana shear zone disrupted this nappe and displaced the suture between 660 and 550 Ma during regional deformation associated with the Najd fault system. These results indicate that at least one suture extends westward into the interior of northern Africa.

  19. Orientation of late Precambrian sutures in the Arabian-Nubian shield

    NASA Technical Reports Server (NTRS)

    Stern, Robert J.; Nielsen, Kent C.; Best, Eric; Sultan, Mohamed; Arvidson, Raymond E.

    1990-01-01

    Recent tectonic models have resulted in conflicting descriptions of how the late Precambrian sutures of the Arabian-Nubian shield extend into northeast Africa. The Hamisana shear zone in northeastern Sudan is critical to this discussion because it truncates and disrupts two sutures, the Allaqi-Heiani and the Onib-Sol Hamed. Analysis of field structural data, Thematic Mapper imagery, and Rb-Sr and U-Pb geochronology suggests that the Allaqi-Heiani suture is the western extension of the Onib-Sol Hamed suture and that both make up the exposed parts of a far-traveled, polydeformed ophiolitic nappe complex. Subsequent deformation localized in the Hamisana shear zone disrupted this nappe and displaced the suture between 660 and 550 Ma during regional deformation associated with the Najd fault system. These results indicate that at least one suture extends westward into the interior of northern Africa.

  20. The preparation of nylon-tube-supported hexokinase and glucose 6-phosphate dehydrogenase and the use of the co-immobilized enzymes in the automated determination of glucose.

    PubMed Central

    Morris, D L; Campbell, J; Hornby, W E

    1975-01-01

    Triethyloxonium tetrafluoroborate was used to O-alkylate nylon-tube thus producing the imidate salt of the nylon which was further made to react with 1,6-diaminohexane. 2. Hexokinase (EC 2.7.1.1) and glucose 6-phosphate dehydrogenase (EC 1.1.1.49) were immobilized on the amino-substituted nylon tube through glutaraldeyde and bisimidates. 3. The effect of varying the conditions of O-alkylation and the amount of enzyme immobilized on the activity of nylon tube-hexokinase derivatives was determined. 4. The effect of varying the amount of enzyme immobilized on the activity of nylon-tube-glucose 6-phosphate dehydrogenase derivatives was determined. 5. The thermal stability of nylon-tube-hexokinase and nylon-tube-glucose 6-phosphate dehydrogenase derivatives was studied. 6. Different ratios of hexokinase and glucose 6-phosphate dehydrogenase were co-immobilized on nylon tube, and the rate of conversion of glucose into 6-phosphogluconolactone was compared with the individual activities of the immobilized enzymes. 7. Hexokinase and glucose 6-phosphate dehydrogenase co-immobilized on nylon tube were used in the automated analysis of glucose. PMID:1167161

  1. Quantitative physical and handling characteristics of novel antibacterial braided silk suture materials.

    PubMed

    Chen, Xiaojie; Hou, Dandan; Tang, Xiaoqi; Wang, Lu

    2015-10-01

    Surgical braided silk sutures have been widely used because these materials exhibit good handling characteristics, ease of use, and ideal knot security. However, surgical silk sutures likely cause surgical site infections because these sutures are composed of natural protein materials with a braided structure. As such, antibacterial silk sutures for clinical wound closure should be developed. Braided silk suture could be treated and modified with antibacterial agent, provided that excellent physical and handling characteristics of this material should maximize maintained. This study aimed to quantitatively investigate the effect of antibacterial treatment with different parameters on physical and handling characteristics of novel antibacterial braided silk sutures. Physical and handling characteristics, including appearance, knot-pull tensile strength, pullout friction resistance, tissue drag friction resistance, and bending stiffness, were evaluated. After physical and handling tests were conducted, images showed morphological characteristics were obtained and evaluated to investigate the relationship between antibacterial treatment and physical and handling properties. Results showed that suture diameter increased and reached the nearest thick size specification; knot-pull tensile strength decreased but remained higher than the standard value by at least 40.73%. Fracture asynchronism during knot-pull tensile strength test suggested that the fineness ratio of shell and core strands may enhance knot-pull tensile strength. Static and dynamic frictions of suture-to-suture friction behavior were slightly affected by antibacterial treatment, and changed to less than 16.07% and 32.77%, respectively. Suture-to-tissue friction and bending stiffness increased by approximately 50%; the bending stiffness of the proposed suture remained efficient compared with that of synthetic sutures. Therefore, good physical and handling characteristics can be maintained by selecting

  2. No-touch, Single-move Technique to Reverse the Needle While Suturing

    PubMed Central

    2016-01-01

    Summary: The aim of the study is to promote the “no-touch” surgical technique while suturing and to describe an easy way to reverse the needle while suturing. We have provided a step-by-step description of how to handle a needle while suturing using the no-touch technique. We have also provided figures for each step. The described technique is an easy, single-move, no-touch technique to reverse the needle.

  3. Electrospun Polymeric Core-sheath Yarns as Drug Eluting Surgical Sutures.

    PubMed

    Padmakumar, Smrithi; Joseph, John; Neppalli, Madhuri Harsha; Mathew, Sumi Elizabeth; Nair, Shantikumar V; Shankarappa, Sahadev A; Menon, Deepthy

    2016-03-23

    Drug-coated sutures are widely used as delivery depots for antibiotics and anti-inflammatory drugs at surgical wound sites. Although drug-laden coating provides good localized drug concentration, variable loading efficiency and release kinetics limits its use. Alternatively, drug incorporation within suture matrices is hampered by the harsh fabrication conditions required for suture-strength enhancement. To circumvent these limitations, we fabricated mechanically robust electrospun core-sheath yarns as sutures, with a central poly-l-lactic acid core, and a drug-eluting poly-lactic-co-glycolic acid sheath. The electrospun sheath was incorporated with aceclofenac or insulin to demonstrate versatility of the suture in loading both chemical and biological class of drugs. Aceclofenac and insulin incorporated sutures exhibited 15% and 4% loading, and release for 10 and 7 days, respectively. Aceclofenac sutures demonstrated reduced epidermal hyperplasia and cellularity in skin-inflammation animal model, while insulin loaded sutures showed enhanced cellular migration in wound healing assay. In conclusion, we demonstrate an innovative strategy of producing mechanically strong, prolonged drug-release sutures loaded with different classes of drugs. PMID:26936629

  4. Patterns and implications of extensive heterochrony in carnivoran cranial suture closure

    PubMed Central

    Goswami, A; Foley, L; Weisbecker, V

    2013-01-01

    Heterochronic changes in the rate or timing of development underpin many evolutionary transformations. In particular, the onset and rate of bone development have been the focus of many studies across large clades. In contrast, the termination of bone growth, as estimated by suture closure, has been studied far less frequently, although a few recent studies have shown this to represent a variable, although poorly understood, aspect of developmental evolution. Here, we examine suture closure patterns across 25 species of carnivoran mammals, ranging from social-insectivores to hypercarnivores, to assess variation in suture closure across taxa, identify heterochronic shifts in a phylogenetic framework and elucidate the relationship between suture closure timing and ecology. Our results show that heterochronic shifts in suture closure are widespread across Carnivora, with several shifts identified for most major clades. Carnivorans differ from patterns identified for other mammalian clades in showing high variability of palatal suture closure, no correlation between size and level of suture closure, and little phylogenetic signal outside of musteloids. Results further suggest a strong influence of feeding ecology on suture closure pattern. Most of the species with high numbers of heterochronic shifts, such as the walrus and the aardwolf, feed on invertebrates, and these taxa also showed high frequency of closure of the mandibular symphysis, a state that is relatively rare among mammals. Overall, caniforms displayed more heterochronic shifts than feliforms, suggesting that evolutionary changes in suture closure may reflect the lower diversity of cranial morphology in feliforms. PMID:23530892

  5. Differential spatial regulation of BMP molecules is associated with single-suture craniosynostosis.

    PubMed

    Whitton, Alaina; Hyzy, Sharon L; Britt, Chelsea; Williams, Joseph K; Boyan, Barbara D; Olivares-Navarrete, Rene

    2016-07-01

    OBJECTIVE The aim of this study was to examine messenger RNA (mRNA) levels of bone morphogenetic protein (BMP) ligands, receptors, and soluble inhibitors in cells isolated from single-suture synostoses from fused coronal, metopic, sagittal, and lambdoid sutures. METHODS Cells were isolated from bone collected from patients undergoing craniotomies at Children's Healthcare of Atlanta. Real-time polymerase chain reaction was used to examine mRNA levels in cells isolated from fused sutures or patent sutures in comparison with levels in normal bone from the same patient. RESULTS Cells isolated from fused sutures in cases of sagittal and coronal synostosis highly expressed BMP2, while cells isolated from fused metopic or lambdoid synostosis expressed high BMP4. Noggin, a BMP inhibitor, was lower in fused sutures and had high expression in patent sutures. CONCLUSIONS These results suggest that BMPs and inhibitors play a significant role in the regulation of suture fusion as well in the maintenance of patency in the normal suture. PMID:27035551

  6. Microarterial anastomoses: A parameterised computational study examining the effect of suture position on intravascular blood flow.

    PubMed

    Wain, R A J; Hammond, D; McPhillips, M; Whitty, J P M; Ahmed, W

    2016-05-01

    This study investigates the extent to which individual aspects of suture placement influence local haemodynamics within microarterial anastomoses. An attempt to physically quantify flow characteristics of blood past microvascular sutures is made using computational fluid dynamics (CFD) software. Particular focus has been placed on increased shear strain rate (SSR), a known precipitant of intravascular platelet activation and thrombosis. Measurements were taken from micrographs of sutured anastomoses in chicken femoral vessels, with each assessed for bite width, suture angle and suture spacing. Computational geometries were then created to represent the anastomosis. Each suture characteristic was parameterised to allow independent or simultaneous adjustment. Flow rates were obtained from anonymised Doppler ultrasound scans of analogous vessels during preoperative assessment for autologous breast reconstruction. Vessel simulations were performed in 2.5mm ducts with blood as the working fluid. Vessel walls were non-compliant and a continuous Newtonian flow was applied, in accordance with current literature. Suture bite angle and spacing had significant effects on local haemodynamics, causing notably higher local SSRs, when simulated at extremes of surgical practice. A combined simulation, encompassing subtle changes of each suture parameter simultaneously i.e. representing optimum technique, created a more favourable SSR profile. As such, haemodynamic changes associated with optimum suture placement are unlikely to influence thrombus formation significantly. These findings support adherence to the basic principles of good microsurgical practice. PMID:26876115

  7. Aprotinin extends mechanical integrity time of cell-seeded fibrin sutures.

    PubMed

    Coffin, Spencer T; Gaudette, Glenn R

    2016-09-01

    Cell therapy has the potential to treat different pathologies, including myocardial infarctions (heart attacks), although cell engraftment remains elusive with most delivery methods. Biological sutures composed of fibrin have been shown to effectively deliver human mesenchymal stem cell (MSC) to infarcted hearts. However, human MSCs rapidly degrade fibrin making cell seeding and delivery time sensitive. To delay the degradation process, we propose using Aprotinin, a proteolytic enzyme inhibitor that has been shown to slow fibrinolysis. Human MSCs seeded on fibrin sutures and incubated with Aprotinin demonstrated similar cell viability, examined using a LIVE/DEAD stain, to controls. No differences in proliferation, as determined by Ki-67 presence, were observed. Human MSCs incubated in Aprotinin differentiated into adipocytes, osteocytes, and chondrocytes, confirming multipotency. The number of cells adhered to fibrin sutures increased through Aprotinin supplementation at 2, 3, and 5 day time points. Uniaxial tensile testing was used to examine the effect of Aprotinin on suture integrity. Sutures exposed to Aprotinin had higher ultimate tensile strength and modulus when compared to sutures exposed to standard growth media. Fibrin sutures incubated in Aprotinin had larger diameters and less fibrin degradation products compared to the controls, confirming decreased fibrinolysis. These data suggest that Aprotinin can reduce degradation of fibrin sutures without significant effects on MSC function, providing a novel method for extending the implantation window and increasing the number of cells delivered via fibrin sutures. © 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 104A: 2271-2279, 2016. PMID:27101153

  8. Elimination of stick-slip of elastomeric sutures by radiofrequency glow discharge deposited coatings.

    PubMed

    Griesser, H J; Chatelier, R C; Martin, C; Vasic, Z R; Gengenbach, T R; Jessup, G

    2000-01-01

    Fine elastomeric sutures intended for cardiovascular surgery can exhibit "stick-slip" behavior as they are pulled through tissue; the resulting oscillatory force can damage delicate tissue or cause sutures to snap. To eliminate this undesirable effect, sutures were surface-modified using a radiofrequency glow discharge in a vapor of either hexamethyldisiloxane or hexamethyldisilazane, to produce a thin polymeric coating on the suture. The same coatings were also deposited onto aluminized tape to facilitate their characterization by measurement of air/water contact angles and by X-ray photoelectron spectroscopy. Coatings from both monomers were found to be very hydrophobic. The hexamethyldisiloxane glow discharge coatings underwent negligible oxidation when stored in air, and thus remained stable over a shelf-life period akin to what may be required of sutures. The hexamethyldisilazane glow discharge coatings, in contrast, incorporated substantial amounts of oxygen over a 3-month period. The coatings did not measurably alter the tensile properties of the sutures. The frictional properties of coated sutures were assessed by measuring the dynamic friction between the suture and ovine myocardium. Both coatings were effective in removing the inherent stick-slip behavior of polybutester sutures in this model. The coatings remained intact after several passes and proved to be robust and efficacious under various strain regimes. PMID:10813763

  9. Patterns and implications of extensive heterochrony in carnivoran cranial suture closure.

    PubMed

    Goswami, A; Foley, L; Weisbecker, V

    2013-06-01

    Heterochronic changes in the rate or timing of development underpin many evolutionary transformations. In particular, the onset and rate of bone development have been the focus of many studies across large clades. In contrast, the termination of bone growth, as estimated by suture closure, has been studied far less frequently, although a few recent studies have shown this to represent a variable, although poorly understood, aspect of developmental evolution. Here, we examine suture closure patterns across 25 species of carnivoran mammals, ranging from social-insectivores to hypercarnivores, to assess variation in suture closure across taxa, identify heterochronic shifts in a phylogenetic framework and elucidate the relationship between suture closure timing and ecology. Our results show that heterochronic shifts in suture closure are widespread across Carnivora, with several shifts identified for most major clades. Carnivorans differ from patterns identified for other mammalian clades in showing high variability of palatal suture closure, no correlation between size and level of suture closure, and little phylogenetic signal outside of musteloids. Results further suggest a strong influence of feeding ecology on suture closure pattern. Most of the species with high numbers of heterochronic shifts, such as the walrus and the aardwolf, feed on invertebrates, and these taxa also showed high frequency of closure of the mandibular symphysis, a state that is relatively rare among mammals. Overall, caniforms displayed more heterochronic shifts than feliforms, suggesting that evolutionary changes in suture closure may reflect the lower diversity of cranial morphology in feliforms. PMID:23530892

  10. Biologic response to orthopedic sutures: a histologic study in a rabbit model.

    PubMed

    Carr, Brian J; Ochoa, Leah; Rankin, David; Owens, Brett D

    2009-11-01

    Biologic reactivity to suture materials can have an effect on patient outcomes. The goal of this study was to determine the histologic response to 8 commonly used orthopedic sutures--Ethibond (Ethicon, Somerville, New Jersey), Ticron (Tyco, Waltham, Massachusetts), HiFi (Linvatec, Largo, Florida), Ultrabraid (Smith & Nephew, Memphis, Tennessee), MaxBraid (Biomet, Warsaw, Indiana), Orthocord (Mitek, Raynham, Massachusetts), MagnumWire (Opus Medical, San Juan Capistrano, California), and FiberWire (Arthrex, Naples, Florida)--using a rabbit model. The suture granuloms were evaluated at 30, 60, and 120 days with measurement of the fibrous capsule, the number of giant cells in and near the capsule, and the overall inflammatory grade: 1 (mild), 2 (moderate), and 3 (severe). MagnumWire and Ticron sutures initiated a more intense inflammatory reaction when compared to the other sutures. By 120 days, MagnumWire (P=.0297) and Ticron (P=.1855) had fewer giant cells at the soft tissue-suture interface, fewer giant cells within the capsule (P=.0074 and P=.0377, respectively), and the greatest capsular thickness of all suture types (P<.0001 and P=.1378, respectively). Differences exist between the biologic reactivity of commonly used orthopedic sutures that may be attributable to their material composition and/or braid characteristics. In comparison to other high-strength sutures, MagnumWire and Ticron stimulated a more intense foreign body inflammatory response. PMID:19902886

  11. Recent advances in biodegradable metals for medical sutures: a critical review.

    PubMed

    Seitz, Jan-Marten; Durisin, Martin; Goldman, Jeremy; Drelich, Jaroslaw W

    2015-09-16

    Sutures that biodegrade and dissolve over a period of several weeks are in great demand to stitch wounds and surgical incisions. These new materials are receiving increased acceptance across surgical procedures whenever permanent sutures and long-term care are not needed. Unfortunately, both inflammatory responses and adverse local tissue reactions in the close-to-stitching environment are often reported for biodegradable polymeric sutures currently used by the medical community. While bioabsorbable metals are predominantly investigated and tested for vascular stent or osteosynthesis applications, they also appear to possess adequate bio-compatibility, mechanical properties, and corrosion stability to replace biodegradable polymeric sutures. In this Review, biodegradable alloys made of iron, magnesium, and zinc are critically evaluated as potential materials for the manufacturing of soft and hard tissue sutures. In the case of soft tissue closing and stitching, these metals have to compete against currently available degradable polymers. In the case of hard tissue closing and stitching, biodegradable sternal wires could replace the permanent sutures made of stainless steel or titanium alloys. This Review discusses the specific materials and degradation properties required by all suture materials, summarizes current suture testing protocols and provides a well-grounded direction for the potential future development of biodegradable metal based sutures. PMID:26172399

  12. Barbed Suture as a Treatment Approach in Complex Degloving Injuries.

    PubMed

    Boudreault, David Jean-Guy; Lance, Sam H; Garcia, Jesus A

    2016-05-01

    In the late19th century, French physician Morel-Lavallée was challenged with a group of patients who sustained similar patterns of degloving injuries, which today carry his eponym. In 1853, he reported a series of cases as well as proposed strategies for the management of these complex degloving injuries. Treatment strategies have not varied significantly over the years, and these lesions continue to plague surgeons today with failure rates in excess of 50%. We present 2 case series using barbed suture in the management of these complex injuries. PMID:26954732

  13. Degranulation and abnormal bactericidal function of granulocytes procured by reversible adhesion to nylon wool.

    PubMed

    Klock, J C; Bainton, D F

    1976-07-01

    Granylocyte bactericidal capacity, chemotaxis, hexose monophosphate shung activity (before and after phagocytic stimulus), and quantitative nitroblue tetrazolium reduction and enzyme content were examined in cells obtained by filtration leukaphresis (FL) and continuous-flow centrifugation (CFC). A decrease in the bactericidal efficiency of FL-produced cells compared to that of both normal and CFC-procured granulocytes was found; the decrease was 17% with a cell-to-bacteria ratio of 5:1, and 55% with a 1:1 ratio. Moreover, FL-acquired cells were often vacuolated and consistently contained less acid phosphatase and beta-glucuronidase than did normal granulocytes. When normal cells were incubated for 1-2 hr with nylon wool, 30% of the total acid phosphatase and beta-glucuronidase was released, with no evidence of cell death, thus suggesting degranulation. Similar results were obtained with glass, cotton, or polysulfone plastic fibers. Electron microscopic and peroxidase cytochemical studies of the adherence of normal granulocytes to nylon fibers were also carried out. After 30 min of incubation, cell-to-fiber attachment and cellular aggregation had occurred, although the cells per se appeared normal. After 60 and 120 min, other changes became apparent: (1) a decrease in the amount of cytoplasmic granules; (2) large, intracytoplasmic vaculoles; and (3) extracellular peroxidase on fiber surfaces. We conclude that granulocytes obtained by adherence to nylon fibers show both morphological and biochemical evidence of degranulation and diminished bactericidal capacity, and that these abnormalities may be causally related to decreased granulocyte survival in transfusion recipients. PMID:947403

  14. MicroArray Facility: a laboratory information management system with extended support for Nylon based technologies

    PubMed Central

    Honoré, Paul; Granjeaud, Samuel; Tagett, Rebecca; Deraco, Stéphane; Beaudoing, Emmanuel; Rougemont, Jacques; Debono, Stéphane; Hingamp, Pascal

    2006-01-01

    Background High throughput gene expression profiling (GEP) is becoming a routine technique in life science laboratories. With experimental designs that repeatedly span thousands of genes and hundreds of samples, relying on a dedicated database infrastructure is no longer an option. GEP technology is a fast moving target, with new approaches constantly broadening the field diversity. This technology heterogeneity, compounded by the informatics complexity of GEP databases, means that software developments have so far focused on mainstream techniques, leaving less typical yet established techniques such as Nylon microarrays at best partially supported. Results MAF (MicroArray Facility) is the laboratory database system we have developed for managing the design, production and hybridization of spotted microarrays. Although it can support the widely used glass microarrays and oligo-chips, MAF was designed with the specific idiosyncrasies of Nylon based microarrays in mind. Notably single channel radioactive probes, microarray stripping and reuse, vector control hybridizations and spike-in controls are all natively supported by the software suite. MicroArray Facility is MIAME supportive and dynamically provides feedback on missing annotations to help users estimate effective MIAME compliance. Genomic data such as clone identifiers and gene symbols are also directly annotated by MAF software using standard public resources. The MAGE-ML data format is implemented for full data export. Journalized database operations (audit tracking), data anonymization, material traceability and user/project level confidentiality policies are also managed by MAF. Conclusion MicroArray Facility is a complete data management system for microarray producers and end-users. Particular care has been devoted to adequately model Nylon based microarrays. The MAF system, developed and implemented in both private and academic environments, has proved a robust solution for shared facilities and

  15. Temperature, moisture, and strain rate effects on the compressive mechanical behavior of Nylon 6/6

    SciTech Connect

    Kawahara, W.A.; Brandon, S.L.; Korellis, J.S.

    1988-04-01

    Material test results are presented for the mechanical behavior of Nylon 66 in compression. Static compression modes include direct compression, stress relaxation and creep. Dynamic direct compression results are included. Tests are performed at atmospheric pressure; strain rates range from 10/sup /minus/4/sec to 10/sup 2/sec; temperatures are 20, 65, 110, 150 and 200/degree/C; moisture levels are 0% (dry), 2% and 6% (saturated); true strains to /minus/0.25 are imposed. Our empirical Temperature-Moisture equivalence of 14/degree/C per 1% moisture is discussed with respect to the /open quotes/free volume/close quotes/ concept.

  16. Shear-induced conformation change in α-crystalline nylon6

    NASA Astrophysics Data System (ADS)

    Arabnejad, Saeid; Manzhos, Sergei; He, Chaobin; Shim, V. P. W.

    2014-12-01

    A study of shear deformation of α-crystalline nylon6 is undertaken, using dispersion-corrected density functional theory. The shear stress-strain relationship and shear strength for interlayer shear deformation are computed. A conformation change induced by shear is identified along twinning deformation, whereby the conformation of chains, specifically the location of non-H-bonded hydrogen atoms, changes continuously. This paves a way for the modulation of properties of this group of materials by small shear deformation, if the non-H-bonded hydrogens are chemically substituted to form non-equivalent conformations when deformed.

  17. Laser ablation at 337 nm of nitrocellulose and nylon sensitized with organic dopants

    NASA Astrophysics Data System (ADS)

    Skordoulis, Constantine D.; Kosmidis, Constantine E.

    1993-05-01

    The laser induced ablative decomposition of nitrocellulose and nylon sensitized with organic dopants (Stilbene 420, Coumarin 120, and Rhodamine 6G) has been studied. Ablation with a low power nitrogen laser is hereby reported for the first time. With the addition of dyes strongly absorbing at 337 nm the photoetching rate of the pure materials can be significantly increased. A two step photochemical mechanism considering the decomposition of the polymers from excited electronic states and the energy transfer process from the dye to the polymer are discussed.

  18. 3D printing of weft knitted textile based structures by selective laser sintering of nylon powder

    NASA Astrophysics Data System (ADS)

    Beecroft, M.

    2016-07-01

    3D printing is a form of additive manufacturing whereby the building up of layers of material creates objects. The selective laser sintering process (SLS) uses a laser beam to sinter powdered material to create objects. This paper builds upon previous research into 3D printed textile based material exploring the use of SLS using nylon powder to create flexible weft knitted structures. The results show the potential to print flexible textile based structures that exhibit the properties of traditional knitted textile structures along with the mechanical properties of the material used, whilst describing the challenges regarding fineness of printing resolution. The conclusion highlights the potential future development and application of such pieces.

  19. Research on the melt impregnation of continuous carbon fiber reinforced nylon 66 composites

    NASA Astrophysics Data System (ADS)

    Jia, M. Y.; Li, C. X.; Xue, P.; Chen, K.; Chen, T. H.

    2016-07-01

    Impregnation mold of continuous carbon fiber reinforced thermoplastic composites was designed and built in the article. Based on the theory of fluid mechanics and Darcy's law, a model of the melt impregnation was also established. The influences of fiber bundle width and impregnation pins’ diameter on the impregnation degree were studied by numerical simulation. Continuous carbon fiber reinforced nylon 66 composites were prepared. The effects of coated angle and impregnation mold temperature on the mechanical properties of the composites were also described.The agreement between the experimental data and prediction by the model was found to be satisfactory.

  20. In-situ polymerization of vinyl pyrrolidinone on nylon 66 by gamma radiation

    SciTech Connect

    Hsieh, Y.L.; Potter, D.; Ellison, M.S.

    1984-10-01

    The polymerization of vinyl pyrrolidinone on nylon 66, with the assistance of aqueous phenol and formic acid, was investigated by mutual and post irradiation procedures. Both solvents were found to greatly facilitate the polymerization with the post irradiation procedure, whereas neither presented any advantage with the mutual irradiation procedure. Tensile properties of the modified fibers were affected in similar ways by both the irradiation procedures and solvents in that the only notable changes were the somewhat higher extensions at yield and at break. The moisture regain values of the treated yarns and fabrics were increased up to three-fold. Surface morphology of the modified fibers was revealed by SEM.

  1. New insights into the relationship between suture closure and craniofacial dysmorphology in sagittal nonsyndromic craniosynostosis

    PubMed Central

    Heuzé, Yann; Boyadjiev, Simeon A; Marsh, Jeffrey L; Kane, Alex A; Cherkez, Elijah; Boggan, James E; Richtsmeier, Joan T

    2010-01-01

    Premature closure of the sagittal suture occurs as an isolated (nonsyndromic) birth defect or as a syndromic anomaly in combination with other congenital dysmorphologies. The genetic causes of sagittal nonsyndromic craniosynostosis (NSC) remain unknown. Although variation of the dysmorphic (scaphocephaly) skull shape of sagittal NSC cases has been acknowledged, this variation has not been quantitatively studied three-dimensionally (3D). We have analyzed the computed tomography skull images of 43 infants (aged 0.9–9 months) with sagittal NSC using anatomical landmarks and semilandmarks to quantify and characterize the within-sample phenotypic variation. Suture closure patterns were defined by dividing the sagittal suture into three sections (anterior, central, posterior) and coding each section as ‘closed’ or ‘fused’. Principal components analysis of the Procrustes shape coordinates representing the skull shape of 43 cases of NSC did not separate individuals by sex, chronological age, or dental stages of the deciduous maxillary first molar. However, analysis of suture closure pattern allowed separation of these data. The central section of the sagittal suture appears to be the first to fuse. Then, at least two different developmental paths towards complete fusion of the sagittal suture exist; either the anterior section or the posterior section is the second to fuse. Results indicate that according to the sequence of sagittal suture closure patterns, different craniofacial complex shapes are observed. The relationship between craniofacial shape and suture closure indicates not only which suture fused prematurely (in our case the sagittal suture), but also the pattern of the suture closure. Whether these patterns indicate differences in etiology cannot be determined with our data and requires analysis of longitudinal data, most appropriately of animal models where prenatal conditions can be monitored. PMID:20572900

  2. Suture of a stab wound of the heart.

    PubMed

    Ellis, Harold

    2015-01-01

    Over many centuries, from the early writings of Galen, 'the father of Medicine', wounds of the heart were considered fatal and outside the remit of surgery. With the advent of anaesthesia, (ether was introduced by William Morton in 1846) and of antiseptic surgery, (Joseph Lister's first publication was in 1867), there was an explosion in the surgery of the abdominal cavity, the chest, the skull and the limbs, yet the heart was considered by the surgical fraternity to be the 'no-go' area of the body. Theodor Billroth, Professor of Surgery in Vienna and himself a pioneer of modern surgery, (he performed the first successful partial gastrectomy for carcinoma of the stomach in 1881), wrote "the surgeon who would attempt to suture a wound of the heart should lose the respect of his colleagues". In London, Stephen Paget, in 1896, wrote: "No new method and no new discovery can overcome the natural difficulties that attend a wound of the heart. It is true that suture has been vaguely proposed as a possible procedure and has been done in animals but I cannot find that it has ever been attempted in practice". (In fact, the heart is an amazingly tough and efficient pump that goes on working, year after year, without ever stopping for a service!). PMID:26309960

  3. Modified arthroscopic suture fixation of a displaced tibial eminence fracture.

    PubMed

    Lehman, Ronald A; Murphy, Kevin P; Machen, M Shaun; Kuklo, Timothy R

    2003-02-01

    This study describes a new arthroscopic method using a whip-stitch technique for treating a displaced type III tibial eminence fracture. A 12-year-old girl who sustained a displaced type III tibial eminence fracture was treated with arthroscopic fixation using the Arthrosew disposable suture device (Surgical Dynamics, Norwalk, CT) to place a whip stitch into the anterior cruciate ligament (ACL). The Arthrex ACL guide (Arthrex, Naples, FL) was used to reduce the avulsed tibial spine fragment. Sutures were then passed through the tibial tunnel and secured over a bony bridge with the knee in 20 degrees of flexion. At 9 months, the patient has a full range of motion with normal Lachman and anterior drawer testing, and she has returned to competitive basketball. Radiographs show complete fracture healing. KT-1000 and isokinetic testing at 9-month follow-up show only minimal side-to-side differences. The Arthrosew device provides a significant advantage in the treatment of type III and IV fractures of the tibial eminence by obtaining arthroscopic fixation within the substance of the ACL, thus obviating arthrotomy and hardware placement. This technique also restores the proper length and tension to the ACL, and provides a simplified, reproducible method of treatment for this injury. PMID:12579135

  4. Modification of the Internal Suture Technique for Mallet Finger

    PubMed Central

    Jiang, Bo; Wang, Peiji; Zhang, Yong; Zhao, Jiaju; Dong, Qirong

    2015-01-01

    Abstract This article describes a treatment of tendinous mallet finger deformities using a modified internal suture technique for the stable fixation of the terminal extensor tendon and bone. Between March 2011 and July 2013, 15 patients with mallet fingers who had been treated using this modification were included in this study. The patients included 10 men and 5 women with a mean age of 33 years (range, 19–50 years). Of these patients, 9 had chronic mallet fingers, 3 were unable to comply with a splinting regimen, and 3 had a history of unsuccessful splinting therapy. The mean time between the injury and surgery was 5.5 months (range, 1–15 months). We graded the results using Crawford criteria. The mean follow-up period was 12 months (range, 9–16 months). The mean final active range of motion of the distal interphalangeal joint flexion was 73° (range, 60°–90°). Based on Crawford evaluation criteria, 8 patients were graded as excellent, 6 were graded as good, and 1 was graded as fair. Apart from 2 documented mild nail deformities, no complications were encountered. This modified technique should be considered for the management of a tendinous mallet finger deformity when the internal suture technique is planned. PMID:25674757

  5. Suture rupture in acromioclavicular joint dislocations treated with flip buttons.

    PubMed

    Motta, Pierorazio; Maderni, Alberto; Bruno, Laura; Mariotti, Umberto

    2011-02-01

    Acute acromioclavicular joint dislocations (ACDs) may be treated arthroscopically with flip buttons. This extra-articular fixation is easy to implant and is well tolerated. Between 2007 and 2009, 20 ACD patients (2 women and 18 men; mean age, 32 years) had surgery by the arthroscopic TightRope technique (Arthrex, Naples, FL). The main complication of this technique that has been reported is the partial loss of reduction at follow-up due to clavicular osteolysis under the superior flip button. We describe 4 cases with loss of reduction due to rupture of the sutures running across the buttons: 2 women with joint hyperlaxity and acute Rockwood grade IV ACD and 2 men, heavy manual workers, with joint hyperlaxity and acute Rockwood grade IV ACD. The use of flip buttons might not be indicated in patients with joint hyperlaxity because they are able to obtain immediate stability only on the vertical plane and not on the horizontal plane. Anteroposterior movements of the acromioclavicular joint might rub the suture against the bone tunnels leading to wear and cutting. PMID:21266279

  6. Modification of conductive properties of (10, 0) zigzag single-walled carbon nanotubes (SWCNT) by alkali metals absorption

    NASA Astrophysics Data System (ADS)

    Hamadanian, Masood; Tavangar, Zahra; Noori, Banafsheh

    2014-11-01

    We have investigated the electronic and structural properties of (10, 0) zigzag single-walled carbon nanotubes (SWCNT) which have adsorbed different alkali metals (X: Li, Na, K, and Cs) and the hydrogen atom by using Density Functional Theory (DFT). It was discovered that among the alkali elements, Li atoms form the strongest bond with SWCNT. In addition, a significant shift was observed in the electronic state of alkali-adsorbed SWCNT compared to pristine SWCNT. Finally, it was proposed that due to showing excellent electronic structure, these modified nanotubes can be applied in new electronic devices, such as transistors, and field emission displays.

  7. Bis-GMA/TEGDMA Dental Composites Reinforced with Electrospun Nylon 6 Nanocomposite Nanofibers Containing Highly Aligned Fibrillar Silicate Single Crystals

    PubMed Central

    Tian, Ming; Gao, Yi; Liu, Yi; Liao, Yiliang; Xu, Riwei; Hedin, Nyle E.; Fong, Hao

    2007-01-01

    The objective of this research was to study the reinforcement of electrospun nylon 6/fibrillar silicate nanocomposite nanofibers on Bis-GMA/TEGDMA dental composites. The hypothesis was that the uniform distribution of nano-scaled and highly aligned fibrillar silicate single crystals into electrospun nylon 6 nanofibers would improve the mechanical properties of the resulting nanocomposite nanofibers, and would lead to the effective reinforcement of dental composites. The nylon 6/fibrillar silicate nanocomposite nanofibers were crystalline, structurally oriented and had an average diameter of approximately 250 nm. To relatively well distribute nanofibers in dental composites, the nanofiber containing composite powders with a particle structure similar to that in interpenetration networks were prepared first, and then used to make the dental composites. The results indicated that small mass fractions (1 % and 2 %) of nanofiber impregnation improved the mechanical properties substantially, while larger mass factions (4 % and 8 %) of nanofiber impregnation resulted in less desired mechanical properties. PMID:17940586

  8. Application of pervaporation and vapor permeation processes to separate aqueous ethanol solution through chemically modified Nylon 4 membranes

    SciTech Connect

    Wang, Y.H.; Teng, M.Y.; Lee, K.R.; Wang, D.M.; Lai, J.Y.

    1998-08-01

    The pervaporation performance of a Nylon 4 membrane, chemically grafted by N,N-dimethylaminoethyl methacrylate (DMAEM), DMAEM-g-N4, was studied by measurement of the permeation ratio and the pervaporation separation index. It was found that the water permselectivity and permeation rate for the chemically modified Nylon 4 membrane were higher than those of the unmodified Nylon 4 membrane. Optimum pervaporation results, a separation factor of 28.3, and a permeation rate of 439 g/m{sup 2}{center_dot}h, were obtained when the degree of grafting was 12.7%. It was also found that all the permeation ratios at low temperature were less than unity. In addition, compared with pervaporation, vapor permeation effectively increases the permselectivity of water.

  9. Synthesis of Ag/CNT hybrid nanoparticles and fabrication of their nylon-6 polymer nanocomposite fibers for antimicrobial applications.

    PubMed

    Rangari, Vijaya K; Mohammad, Ghouse M; Jeelani, Shaik; Hundley, Angel; Vig, Komal; Singh, Shree Ram; Pillai, Shreekumar

    2010-03-01

    Ag-coated CNTs hybrid nanoparticles (Ag/CNTs) were prepared by ultrasonic irradiation of dimethylformamide (DMF) and silver (I) acetate precursors in the presence of CNTs. The morphology of Ag/CNTs was characterized using x-ray diffraction and transmission electron microscopy (TEM) techniques. The Nylon-6 powder and 1 wt% Ag/CNTs mixture was dispersed uniformly using a noncontact spinning technique. The dried mixture was melted in a single screw extrusion machine and then extruded through an orifice. Extruded filaments were later stretched and stabilized by sequentially passing them through a set of tension adjusters and a secondary heater. The Nylon-6/Ag/CNT hybrid polymer nanocomposite (HPNC) fibers, which were of approximately 80 microm size, were tested for their tensile properties. The failure stress and modulus of the extruded HPNC fibers (doped with 1% Ag/CNTs) was about 72.19 % and 342.62% higher than the neat extruded Nylon-6 fiber, respectively. DSC results indicated an increase in the thermal stability and crystallization for HPNC fibers. The antibacterial activity of the Ag-coated CNTs, commercial Ag, neat Nylon-6 and plain CNTs were evaluated. Ag-coated CNTs at 25 microg demonstrated good antimicrobial activity against four common bacterial pathogens as tested by the Kirby-Bauer assay. The mean diameters of the zones of inhibition were 27.9 +/- 6.72 mm, 19.4 +/- 3.64 mm, 21.9 +/- 4.33 mm, and 24.1 +/- 4.14 mm, respectively, for Staphylococcus aureus, Streptococcus pyogenes, Escherichia coli and Salmonella enterica serovar Typhimurium. By comparison, those obtained using the broad spectrum antibiotic amoxicillin-clavulanic acid were 37.7 +/- 2.13 mm, 28.6 +/- 4.27 mm, 22.6 +/- 1.27 mm, and 27.0 +/- 1.41 mm, respectively, for the same strains. The zones of inhibition obtained for Nylon-6 Ag-coated CNT powder at 25 microg were also high, ranging from 15.2 to 25.3 mm in contrast to commercial silver or neat Nylon-6, which did not inhibit the bacterial

  10. Synthesis of Ag/CNT hybrid nanoparticles and fabrication of their Nylon-6 polymer nanocomposite fibers for antimicrobial applications

    NASA Astrophysics Data System (ADS)

    Rangari, Vijaya K.; Mohammad, Ghouse M.; Jeelani, Shaik; Hundley, Angel; Vig, Komal; Ram Singh, Shree; Pillai, Shreekumar

    2010-03-01

    Ag-coated CNTs hybrid nanoparticles (Ag/CNTs) were prepared by ultrasonic irradiation of dimethylformamide (DMF) and silver (I) acetate precursors in the presence of CNTs. The morphology of Ag/CNTs was characterized using x-ray diffraction and transmission electron microscopy (TEM) techniques. The Nylon-6 powder and 1 wt% Ag/CNTs mixture was dispersed uniformly using a noncontact spinning technique. The dried mixture was melted in a single screw extrusion machine and then extruded through an orifice. Extruded filaments were later stretched and stabilized by sequentially passing them through a set of tension adjusters and a secondary heater. The Nylon-6/Ag/CNT hybrid polymer nanocomposite (HPNC) fibers, which were of ~ 80 µm size, were tested for their tensile properties. The failure stress and modulus of the extruded HPNC fibers (doped with 1% Ag/CNTs) was about 72.19 % and 342.62% higher than the neat extruded Nylon-6 fiber, respectively. DSC results indicated an increase in the thermal stability and crystallization for HPNC fibers. The antibacterial activity of the Ag-coated CNTs, commercial Ag, neat Nylon-6 and plain CNTs were evaluated. Ag-coated CNTs at 25 µg demonstrated good antimicrobial activity against four common bacterial pathogens as tested by the Kirby-Bauer assay. The mean diameters of the zones of inhibition were 27.9 ± 6.72 mm, 19.4 ± 3.64 mm, 21.9 ± 4.33 mm, and 24.1 ± 4.14 mm, respectively, for Staphylococcus aureus, Streptococcus pyogenes, Escherichia coli and Salmonella enterica serovar Typhimurium. By comparison, those obtained using the broad spectrum antibiotic amoxicillin-clavulanic acid were 37.7 ± 2.13 mm, 28.6 ± 4.27 mm, 22.6 ± 1.27 mm, and 27.0 ± 1.41 mm, respectively, for the same strains. The zones of inhibition obtained for Nylon-6 Ag-coated CNT powder at 25 µg were also high, ranging from 15.2 to 25.3 mm in contrast to commercial silver or neat Nylon-6, which did not inhibit the bacterial strains tested. Further, the

  11. Hematopoiesis on nylon mesh templates. I. Long-term culture of rat bone marrow cells.

    PubMed

    Naughton, B A; Preti, R A; Naughton, G K

    1987-01-01

    Rodent hematopoietic cells have been perpetuated in long-term bone marrow culture (LTBMC), provided that they were plated onto a pre-established layer of bone marrow stromal cells (fibroblasts, reticular cells, adipocytes, macrophages, etc.). This monolayer-type system supports the self-renewal of murine pluripotent stem cells and produces substantial numbers of progenitors and mature cells of the myeloid lineage. In an effort to increase the growth potential of cells in LTBMC, an adherent matrix of stromal cells was established on a pretreated nylon screen template. Subsequent seeding of hematopoietic cells onto this matrix occurred both on the surface of the adherent layer and in the interstices formed by the developing stromal cells. A three dimensional growth pattern of hematopoietic colonies and clusters was observed. Mature cells and late stage precursors of the myeloid and erythroid series were observed in the non-adherent layer for the duration of the experiment (39 weeks). Cells similar in appearance to small lymphocytes were also seen in both the non-adherent and adherent layers. Cells associated with the adherent layer of this LTBMC system displayed the ability to reconstitute hematopoiesis in the irradiated host. It is suggested that because of its three-dimensional nature the nylon mesh LTBMC system possesses a greater hematologic potential per unit area than monolayer-type LTBMC. PMID:3480934

  12. Rigid Nylon Foil-Anchored Polytetrafluoroetyhlene (Gor-Tex) Sheet Stenting For Conjunctival Fornix Reconstruction

    PubMed Central

    Demirci, Hakan; Elner, Susan G.; Elner, Victor M.

    2011-01-01

    Purpose To describe a surgical technique that deepens foreshortened conjunctival fornices by providing a scaffold for epithelialization that opposes contractile forces during wound healing. Design Retrospective interventional case series Participants Seventeen patients with anophthalmic sockets containing foreshortened conjunctival fornices Methods Conjunctival fornices was reconstructed with stents of expanded polytetrafluoroethylene (e-PTFE) sheet draped over rigid, 0.8 mm thick nylon strips that were anchored to the orbital rim. Preoperative and postoperativesymptoms, prosthesis retention, fornix depth, and lagophthalmos were assessed. Main Outcome Measure Prosthesis retention, fornix depth, and lagophthalmos Results All 17 patients had preoperative inability to retain their prosthesis. After postoperative follow-up of 47 ± 43 months, retention was improved in all patients and was entirely satisfactory in 15 (88%) patients. After reconstruction, the repaired fornix was deep in 7 (41%) patients, adequate to retain a prosthesis in 9 (53%) patients, and shallow in 1 (6%) patient. Lagophthalmos improved in 15 (88%) patients and remained unchanged in 2 (12%) patients. Superior fornix was reconstructed concurrently with the inferior fornix in 6 patients. In these patients, the superior fornix improved to deep (3 patients; 50%) or adequate (2; 33%). In 1 (17%) patient, it remained shallow. Conclusion Rigid, nylon-foil anchored e-PTFE stenting opposes postoperative contracture, improving prosthesis retention, and lagophthalmos. It does not require an additional surgical site for graft harvesting. PMID:20691479

  13. A novel approach for application of nylon membranes in the biosensing domain

    NASA Astrophysics Data System (ADS)

    Farahmand, Elham; Ibrahim, Fatimah; Hosseini, Samira; Rothan, Hussin A.; Yusof, Rohana; Koole, Leo H.; Djordjevic, Ivan

    2015-10-01

    In this paper we report the polymer-coated microporous nylon membranes and their application as platforms for protein immobilization and subsequent detection of the dengue virus (DV) in blood serum. Protein recognition experiments were performed with enzyme-linked immunosorbent assay (ELISA). The polymers used for coatings were synthesized by free-radical polymerization reaction between methyl methacrylate (MMA) and methacrylic acid (MAA) in different concentrations. The MAA monomer has carefully been chosen to generate polymers with pendant carboxyl (-COOH) groups, which also exist on polymer surfaces. A high degree of control over surface-exposed -COOH groups has been achieved through variation of monomers concentration in polymerization reaction. The general aspect of this work relies on the dengue antibody (Ab) immobilization on surface -COOH groups via physical attachment or covalent immobilization. Prior to Ab immobilization and ELISA experiment, polymer-coated nylon samples were analyzed in detail for their physical properties by atomic force microscopy (AFM), scanning electron microscopy (SEM), and water-in-air contact angle (WCA) measurements. Membranes were further analyzed by Fourier transform infrared spectroscopy (FTIR) in order to establish the relationship between wettability, porosity, and surface roughness with chemical composition and concentration of -COOH groups on the coating's surface. Optimized coatings have shown high sensitivity towards dengue Ab molecules, revealing fundamental aspect of polymer-protein interfaces as a function of surface -COOH groups' concentration.

  14. Atrazine adsorption removal with nylon6/polypyrrole core-shell nanofibers mat: possible mechanism and characteristics

    NASA Astrophysics Data System (ADS)

    Yang, Bi-Yi; Cao, Yang; Qi, Fei-Fei; Li, Xiao-Qing; Xu, Qian

    2015-05-01

    A functionalized nylon6/polypyrrole core-shell nanofibers mat (PA6/PPy NFM) was prepared via situ polymerization on nylon6 electrospun nanofibers mat (PA6 NFM) template and used as an adsorbent to remove atrazine from aqueous solutions. The core-shell structure of PA6/PPy NFM can be clearly proved under scanning electron microscope (SEM), transmission electron microscopy (TEM), and X-ray photoelectron spectroscopy (XPS). The effects of initial solution pH and ionic strength, as well as the comparison of the adsorption capacity of functionalized (PA6/PPy NFM) and non-functionalized (PA6 NFM) adsorbent, were examined to reveal the possible adsorption mechanism. The results indicated that π-π interaction and electrostatic interaction should play a key role in the adsorption process. The kinetics and thermodynamics studies also further elucidated the detailed adsorption characteristics of atrazine removal by PA6/PPy NFM. The adsorption of atrazine could be well described by the pseudo-second-order equation. The adsorption equilibrium data was well fitted with the Freundlich isotherm model with a maximum adsorption capacity value of 14.8 mg/g. In addition, the increase of adsorption rate caused by a temperature increase could be felicitously explained by the endothermic reaction. The desorption results showed that the adsorption capacity remained almost unchanged after six adsorption/desorption cycles. These results suggest that PA6/PPy NFM could be employed as an efficient adsorbent for removing atrazine from contaminated water sources.

  15. Fabrication of porous calcite using chopped nylon fiber and its evaluation using rats.

    PubMed

    Ishikawa, Kunio; Tram, Nguyen Xuan Thanh; Tsuru, Kanji; Toita, Riki

    2015-02-01

    Although porous calcite has attracted attention as bone substitutes, limited studies have been made so far. In the present study, porous calcite block was fabricated by introducing chopped nylon fiber as porogen. Ca(OH)2 powder containing 10 wt% chopped nylon fiber was compacted at 150 MPa, and sintered to burn out the fiber and to carbonate the Ca(OH)2 under stream of 1:2 O2-CO2. Sintering of Ca(OH)2 at 750 °C or lower temperature resulted in incomplete burning out of the fiber whereas sintering at 800 °C or higher temperature resulted in the formation of CaO due to the thermal decomposition of Ca(OH)2. However, sintering at 770 °C resulted in complete burning out of the fiber and complete carbonation of Ca(OH)2 to calcite without forming CaO. Macro- and micro-porosities of the porous calcite were approximately 23 and 16%, respectively. Diameter of the macropores was approximately 100 μm which is suitable for bone tissue penetration. Porous calcite block fabricated by this method exhibited good tissue response when implanted in the bone defect in femur of 12-weeks-old rat. Four weeks after implantation, bone bonded on the surface of calcite. Furthermore, bone tissue penetrated interior to the macropore at 8 weeks. These results demonstrated the good potential value of porous calcite as artificial bone substitutes. PMID:25649514

  16. Survey of Primary Aromatic Amines and Colorants in Polyurethane, Nylon and Textile Toys.

    PubMed

    Abe, Yutaka; Yamaguchi, Miku; Mutsuga, Motoh; Akiyama, Hiroshi; Kawamura, Yoko

    2016-01-01

    The residual and migration levels of 28 primary aromatic amines (PAAs) in polyurethane and nylon toys were determined using LC-MS/MS, and the migration and residual amounts of PAAs and 15 colorants in textile toys were determined using LC-MS/MS and LC-TOF-MS according to the European Standard EN71. Among 34 polyurethane toy samples, 2,6-diaminotoluene and 2,4-diaminotoluene were detected in the same 12 samples at residual levels ranging from 2.1 to 19.7 and from 7.6 to 39.6 μg/g, respectively. Furthermore, 4,4'-diaminodiphenylmethane (4,4'-MDA) and aniline were detected in 9 samples (from 0.2 to 8.7 μg/g), and one sample (0.4 μg/g), respectively. PAAs were not detected in the 8 samples of nylon toys. As for the migration test into water, only 4,4'-MDA migrated from 3 polyurethane toys at levels ranging from 0.4 to 2.5 μg/g. PAAs did not migrate from the 43 textile toys, but colorants such as Solvent Yellow 1 and Basic Red 9 were detected at the residual level of 0.02 μg/g. The residual levels of PAAs and colorants detected in this study were significantly lower than the limit values established by the European Union regulation. PMID:27211915

  17. Modification of nylon-6 fibres by radiation-induced graft polymerisation of vinylbenzyl chloride

    NASA Astrophysics Data System (ADS)

    Ting, T. M.; Nasef, Mohamed Mahmoud; Hashim, Kamaruddin

    2015-04-01

    Modification of nylon-6 fibres by radiation-induced graft copolymerisation (RIGP) of vinylbenzyl chloride (VBC) using the preirradiation method was investigated. A number of grafting parameters such as type of solvent, total dose, monomer concentrations, reaction temperature and reaction time were studied to obtain desired degree of grafting (DG). The DG was found to be a function of reaction parameters and achieved a maximum value of 130 wt% at 20 vol% VBC concentration in methanol, 300 kGy dose, 30 °C temperature and 3 h reaction time. Fourier-transform infrared spectroscopy (FTIR), scanning electron microscopy (SEM) and X-ray diffraction (XRD) were employed to evaluate the chemical, morphological and structural changes that occurred in the grafted fibres, respectively. Thermogravimetric analysis (TGA) was also applied to determine the thermal stability, whereas differential scanning calorimeter (DSC) and universal mechanical tester were used to analyse respective thermal and mechanical properties of the grafted fibres. The results of these analyses provide strong evidence for successful grafting of VBC onto nylon-6, and the variation in the properties of the grafted fibres depends on DG.

  18. Piezoelectric inkjet printing of a cross-hatch immunoassay on a disposable nylon membrane.

    PubMed

    Stewart, Thomas N; Pierson, Bonnie E; Aggarwal, Ravi; Narayan, Roger J

    2009-02-01

    The development of a cost-effective method for manufacturing immunoassays is a key step towards their commercial use. In this study, a piezoelectric inkjet printer and a nylon membrane were used to fabricate a disposable immunoassay. Using a piezoelectric inkjet printer, a cross-hatch pattern of goat anti-mouse antibody (GalphaM) and rabbit anti-horseradish peroxidase (RalphaHRP) antibody were deposited on the nylon membrane. These patterns were subsequently treated with a solution containing rabbit anti-goat antibody labeled with horseradish peroxidase (RalphaG-HRP). The effectiveness of the immobilization process was examined using tetramethylbenzidine (TMB), which oxidizes in the presence of HRP to form a visible precipitate. Optical evaluation of the TMB precipitate was used to assess the precision of the features in the inkjet-printed pattern as well as antibody functionality following inkjet printing. Uniform patterns that contained functional antibodies were fabricated using the piezoelectric inkjet printer. These results suggest that piezoelectric inkjet printing may be used to fabricate low-cost disposable immunoassays for biotechnology and healthcare applications. PMID:19226553

  19. Interactive Virtual Suturing Simulations: Enhancement of Student Learning in Veterinary Medicine

    ERIC Educational Resources Information Center

    Staton, Amy J.; Boyd, Christine B.

    2013-01-01

    This capstone addresses an instructional gap in the Morehead State University Veterinary Technology Program and in other similar programs around the globe. Students do not retain the knowledge needed to proficiently complete suture patterns nor do students receive sufficient instructional time during the year to master each suture pattern that is…

  20. Blood flow through sutured and coupled microvascular anastomoses: a comparative computational study.

    PubMed

    Wain, Richard A J; Whitty, Justin P M; Dalal, Milind D; Holmes, Michael C; Ahmed, Waqar

    2014-07-01

    This study uses computational fluid dynamics (CFD) to model blood flow through idealised sutured and coupled arterial anastomoses to investigate the affect of each technique on intravascular blood flow. Local flow phenomena are examined in detail to study characteristics that potentially initiate thrombus formation; for example, changes in velocity profile, wall shear stress (WSS), and shear strain rate (SSR). Idealised geometries of sutured and coupled anastomoses were created with dimensions identical to microvascular suture material and a commercially available coupling device using CFD software. Vessels were modelled as non-compliant 1 mm diameter ducts, and blood was simulated as a Newtonian fluid, in keeping with previous studies. All analyses were steady-state and performed on arteries. The sutured simulation revealed a reduced boundary velocity profile; high WSS; and high SSR at the suture sites. The coupled anastomosis simulation showed a small increase in maximum WSS at the anastomotic region compared to a pristine vessel, however, this was less than half that of the sutured model. The coupled vessel displayed an average WSS equivalent to a pristine vessel simulation. Taken together these observations demonstrate a theoretically more thrombogenic profile in a sutured anastomosis when compared to a coupled vessel. Data from simulations on a coupled anastomosis reveal a profile that is nearly equivalent to that of a pristine vessel. Based purely on the combination of less favourable flow properties shown using these idealised arterial models, the sutured method is potentially more thrombogenic than a coupled anastomosis. PMID:24731801

  1. Arthroscopic repair of peripheral triangular fibrocartilage complex tears with suture welding: a technical report.

    PubMed

    Badia, Alejandro; Jiménez, Alexis

    2006-10-01

    This report presents a method of arthroscopic repair of the peripheral triangular fibrocartilage complex tears that replaces traditional suture knots with ultrasonic welding of sutures. This will help eliminate potential causes of ulnar-sided wrist discomfort during the postoperative period. PMID:17027791

  2. Barbed Suture: A Review of the Technology and Clinical Uses in Obstetrics and Gynecology

    PubMed Central

    Greenberg, James A; Goldman, Randi H

    2013-01-01

    Surgical knots are simply a necessary evil needed to anchor smooth suture to allow it to function in its role in tissue reapproximation. Surgical knots reduce the tensile strength of all sutures by thinning and stretching the material. The tying of surgical knots introduces the potential of human error and interuser variability. Knot-secured smooth suture must create an uneven distribution of tension across the wound with the higher tension burdens placed at the knots. Given the excessive relative wound tension on the knot and the reasonable concerns of surgeons for suture failure due to knot slippage, there is a natural tendency toward overcoming these concerns by over-tightening knots; however, tighter knots may be worse for wound healing and strength than looser knots. In minimally invasive laparoscopic surgeries, the ability to quickly and properly tie surgical knots presents a new challenge. In cases in which knot tying is difficult, the use of knotless barbed suture can securely reapproximate tissues with less time, cost, and aggravation. This article reviews the technology behind barbed sutures with a focus on understanding how they differ from traditional smooth sutures and how barbed sutures have performed in in vitro and animal model testing, as well as in human clinical trials. PMID:24920976

  3. Adherence of methicillin-resistant Staphylococcus pseudintermedius to suture materials commonly used in small animal surgery.

    PubMed

    Morrison, Shauna; Singh, Ameet; Rousseau, Joyce; Weese, J Scott

    2016-02-01

    OBJECTIVE To evaluate adherence of methicillin-resistant Staphylococcus pseudintermedius (MRSP) to 5 suture materials commonly used in small animal surgery. SAMPLE 10 epidemiologically unrelated MRSP isolates (obtained from dogs with clinical infections) that had strong biofilm-forming ability and 5 types of suture. PROCEDURES The 5 types of suture evaluated were monofilament polyglecaprone 25, monofilament polydioxanone, triclosan-coated (TC)-monofilament polydioxanone, braided polyglactin 910, and barbed monofilament polydioxanone. Suture segments were incubated in standard suspensions of MRSP for 2 minutes. Segments were then placed in tryptone soy broth and incubated overnight. After incubation, segments were rinsed with PBS solution and sonicated to dislodge adherent bacteria. Resulting suspensions were used to create serial dilutions that were plated, incubated overnight, and counted the following day. Bacterial adherence to 1 segment of each suture type was assessed by use of scanning electron microscopy. RESULTS There was significantly less adherence of MSRP to TC-monofilament polydioxanone than to polyglecaprone 25, polyglactin 910, barbed monofilament polydioxanone, and monofilament polydioxanone. There was significantly less adherence of MSRP to polyglecaprone than to polyglactin 910. CONCLUSIONS AND CLINICAL RELEVANCE Barbed suture had a bacterial adherence profile comparable to that for monofilament suture. Adherence of MRSP was greatest for braided polyglactin 910. Use of TC-monofilament polydioxanone can be considered for patients that are at high risk of developing surgical site infections and for which a surgeon chooses a multifilament suture. (Am J Vet Res 2016;77:194-198). PMID:27027714

  4. A mathematical model for mechanotransduction at the early steps of suture formation

    PubMed Central

    Khonsari, R. H.; Olivier, J.; Vigneaux, P.; Sanchez, S.; Tafforeau, P.; Ahlberg, P. E.; Di Rocco, F.; Bresch, D.; Corre, P.; Ohazama, A.; Sharpe, P. T.; Calvez, V.

    2013-01-01

    Growth and patterning of craniofacial sutures is subjected to the effects of mechanical stress. Mechanotransduction processes occurring at the margins of the sutures are not precisely understood. Here, we propose a simple theoretical model based on the orientation of collagen fibres within the suture in response to local stress. We demonstrate that fibre alignment generates an instability leading to the emergence of interdigitations. We confirm the appearance of this instability both analytically and numerically. To support our model, we use histology and synchrotron X-ray microtomography and reveal the fine structure of fibres within the sutural mesenchyme and their insertion into the bone. Furthermore, using a mouse model with impaired mechanotransduction, we show that the architecture of sutures is disturbed when forces are not interpreted properly. Finally, by studying the structure of sutures in the mouse, the rat, an actinopterygian (Polypterus bichir) and a placoderm (Compagopiscis croucheri), we show that bone deposition patterns during dermal bone growth are conserved within jawed vertebrates. In total, these results support the role of mechanical constraints in the growth and patterning of craniofacial sutures, a process that was probably effective at the emergence of gnathostomes, and provide new directions for the understanding of normal and pathological suture fusion. PMID:23516237

  5. Mechanical Properties of Cranial Bones and Sutures in 1–2-Year-Old Infants

    PubMed Central

    Wang, Jiawen; Zou, Donghua; Li, Zhengdong; Huang, Ping; Li, Dongri; Shao, Yu; Wang, Huijun; Chen, Yijiu

    2014-01-01

    Background The mechanical properties of 1–2-year-old pediatric cranial bones and sutures and their influential factors were studied to better understand how the pediatric calvarium reacts to loading. Material/Methods Cranial bone and suture specimens were extracted from seven fresh-frozen human infant cadavers (1.5±0.5 years old). Eight specimens were obtained from each subject: two frontal bones, two parietal bones, two sagittal suture samples, and two coronal suture samples. The specimens were tested in a three-point bend setup at 1.5 mm/s. The mechanical properties, such as ultimate stress, elastic modulus, and ultimate strain, were calculated for each specimen. Results The ultimate stress and elastic modulus of the frontal bone were higher than those of the parietal bone (P<0.05). No differences were found between the coronal and sagittal sutures in ultimate stress, elastic modulus, or ultimate strain (P>0.05). The ultimate stress and elastic modulus of the frontal and parietal bones were higher than those of the sagittal and coronal sutures (P<0.05), whereas the opposite ultimate strain findings were revealed (P<0.05). Conclusions There was no significant difference in ultimate stress, elastic modulus, or ultimate strain between the sagittal and coronal sutures. However, there were significant differences in ultimate stress, elastic modulus, and ultimate strain between the frontal and parietal bones as well as between the cranial bones and sutures. PMID:25279966

  6. A novel suture retention test for scaffold strength characterization in ophthalmology.

    PubMed

    Küng, Florian; Schubert, Dirk W; Stafiej, Piotr; Kruse, Friedrich E; Fuchsluger, Thomas A

    2016-12-01

    Sutures are a common way to attach scaffolds in patients. For tubular cardiac scaffolds, the 'suture retention strength' is commonly used to evaluate the resistance of a scaffold against the pull-out of a suture. In order to make this quantity accessible for ophthalmological scaffolds the test procedure has been modified in a novel way. Polycaprolactone (PCL) films of different thicknesses and an amniotic membrane (AM) were used for the experiments. Circular samples with a radius of 7mm were taken and a suture was passed through each sample and tied to a loop. The sample was clamped in a tensile tester and a bolt was passed through the loop. The suture was then pulled with a constant deformation rate until pull-out occurred. The suture retention strength, the deformation at the suture retention strength, and the deformation at rupture were determined for each sample. The presented modified suture retention test allows to measure the relevant parameters of samples on the scale of ophthalmological scaffolds in a reproducible way. A comparison between the first data on PCL and AM has been made. PMID:27612789

  7. Mussel-inspired nanofibrous sheet for suture-less stomach incision surgery.

    PubMed

    Jiang, J; Wan, W; Ge, L; Bu, S; Zhong, W; Xing, M

    2015-05-21

    We report a dopamine-based crosslinker-conjugated gelatin/polycaprolactone nanofibrous sheet. The nanosheet was then employed to treat stomach incisions without sutures during surgery. The mussel-inspired nanosheets, combining the advantages adhesion and tissue repair, show promise for use in treatments of fragile tissues and to avoid suture-caused stress concentration. PMID:25912340

  8. An innovative method to evaluate the suture compliance in sealing the surgical wound lips

    PubMed Central

    Saleh, Farid; Palmieri, Beniamino; Lodi, Danielle; Al-Sebeih, Khalid

    2008-01-01

    Background and aim: The increasing number of surgical procedures performed with local anesthesia, followed by immediate patient discharge from the hospital, emphasizes the need for a tight waterproof suture that is capable of maintaining its tensile strength in the postoperative phase when the wound tumescence, edema due to the anesthetic drug, and surgical trauma disappear. Moreover, the issue of having an accurate surgical wound closure is very relevant in vivo in order to prevent hemorrhage and exogenous microbial infections. This study aimed at designing a new a lab technique that could be used for evaluating the best surgical material. Using such a technique, we compared the wound-lip-sealing properties of three commonly-used suture threads, namely polyurethane, polypropylene, and polyamide. Materials and methods: The mechanical properties of same-size suture threads made from polyurethane, polypropylene, and polyamide, were compared in order to define the one that possess the best elastic properties by being able to counteract the tension-relaxation process in the first 12 hours following surgery. The tension holding capacity of the suture materials was measured in both in vivo and in vitro experiments. The surface area of the scar associated with the three different suture threads was measured and compared, and the permeability of the three different suture threads was assessed at 0 minute, 2 minute, 4 minute, 6 minute, and 8 minute- interval. Results: Results showed that polyurethane suture threads had significantly (P < 0.05) better tensile strength, elongation endurance before breakage, and better elasticity coefficient as compared to polypropylene and polyamide suture threads. Moreover, polyurethane suture threads were significantly (P < 0.05) more impermeable as compared to the other two suture thread types (polypropylene and polyamide). This impermeability was also associated with a tighter wound-lip-sealing ability, and with significantly (P < 0

  9. Accuracy of Suture Passage During Arthroscopic Remplissage—What Anatomic Landmarks Can Improve It?

    PubMed Central

    Garcia, Grant H.; Degen, Ryan M.; Liu, Joseph N.; Kahlenberg, Cynthia A.; Dines, Joshua S.

    2016-01-01

    Background: Recent data suggest that inaccurate suture passage during remplissage may contribute to a loss of external rotation, with the potential to cause posterior shoulder pain because of the proximity to the musculotendinous junction. Purpose: To evaluate the accuracy of suture passage during remplissage and identify surface landmarks to improve accuracy. Study Design: Descriptive laboratory study. Methods: Arthroscopic remplissage was performed on 6 cadaveric shoulder specimens. Two single-loaded suture anchors were used for each remplissage. After suture passage, position was recorded in reference to the posterolateral acromion (PLA), with entry perpendicular to the humeral surface. After these measurements, the location of posterior cuff penetration was identified by careful surgical dissection. Results: Twenty-four sutures were passed in 6 specimens: 6 sutures (25.0%) were correctly passed through the infraspinatus tendon, 12 (50%) were through the infraspinatus muscle or musculotendinous junction (MTJ), and 6 (25%) were through the teres minor. Suture passage through the infraspinatus were on average 25 ± 5.4 mm inferior to the PLA, while sutures passing through the teres minor were on average 35.8 ± 5.7 mm inferior to the PLA. There was an odds ratio of 25 (95% CI, 2.1-298.3; P < .001) that the suture would be through the infraspinatus if the passes were less than 3 cm inferior to the PLA. Sutures passing through muscle and the MTJ were significantly more medial than those passing through tendon, measuring on average 8.1 ± 5.1 mm lateral to the PLA compared with 14.5 ± 5.5 mm (P < .02). If suture passes were greater than 1 cm lateral to the PLA, it was significantly more likely to be in tendon (P = .013). Conclusion: We found remplissage suture passage was inaccurate, with only 25% of sutures penetrating the infraspinatus tendon. Passing sutures 1 cm lateral and within 3 cm inferior of the PLA improves the odds of successful infraspinatus tenodesis

  10. Lateral intercrural suture in the caucasian nose: Decreased domal divergence angle in endonasal rhinoplasty without delivery

    PubMed Central

    Berger, Cezar Augusto Sarraf; Mocelin, Marcos; Soares, Caio Márcio Correia; Pasinato, Rogério; Frota, Andreia Ellery

    2012-01-01

    Summary Introduction: Several techniques can be performed to improve nasal tip definition such as cartilage resection, tip grafts, or sutures. Objctive: To evaluate the outcome of lateral intercrural suture at the lower lateral cartilage by endonasal rhinoplasty with a basic technique without delivery in decreasing the angle of domal divergence and improving the nasal tip definition. Method: This prospective study was performed in 64 patients in which a suture was made on the board head of the lower lateral cartilage in the joint between the dome and lateral crus, using polydioxanone (PDS) with sharp, curved needle. Results: In all of the cases, better definition of the nasal tip was achieved by intercrural suturing for at least 6 months postoperatively. Conclusion: Lateral intercrural suture of the lower lateral cartilage provides improved nasal tip definition and can be performed by endonasal rhinoplasty without delivery in the Caucasian nose. PMID:25991941

  11. A New Removable Uterine Compression by a Brace Suture in the Management of Severe Postpartum Hemorrhage

    PubMed Central

    Aboulfalah, Abderrahim; Fakhir, Bouchra; Ait Ben Kaddour, Yassir; Asmouki, Hamid; Soummani, Abderraouf

    2014-01-01

    Postpartum hemorrhage (PPH) is a life-threatening complication of delivery. It is the leading cause of maternal mortality. During the last 15 years, several total uterine compressive sutures were described in literature. They have proven their effectiveness and safety in the management of severe PPH as an alternative to hysterectomy. We present in this paper a new technique of uterine compressive sutures based on removable uterine brace compressive sutures with compression of the uterus against the pubis. This technique may be more effective by using two mechanisms of uterine bleeding control and also may prevent uterine synechia by respecting the uterine cavity and the removal of the suture 1 or 2 days later. We also present the results of a 15 patients’ series using this new suture. PMID:25593967

  12. Optimal Needle Grasp Selection for Automatic Execution of Suturing Tasks in Robotic Minimally Invasive Surgery

    PubMed Central

    Liu, Taoming; Çavuşoğlu, M. Cenk

    2015-01-01

    This paper presents algorithms for optimal selection of needle grasp, for autonomous robotic execution of the minimally invasive surgical suturing task. In order to minimize the tissue trauma during the suturing motion, the best practices of needle path planning that are used by surgeons are applied for autonomous robotic surgical suturing tasks. Once an optimal needle trajectory in a well-defined suturing scenario is chosen, another critical issue for suturing is the choice of needle grasp for the robotic system. Inappropriate needle grasp increases operating time requiring multiple re-grasps to complete the desired task. The proposed methods use manipulability, dexterity and torque metrics for needle grasp selection. A simulation demonstrates the proposed methods and recommends a variety of grasps. Then a realistic demonstration compares the performances of the manipulator using different grasps. PMID:26413382

  13. Preparation of Surface Adsorbed and Impregnated Multi-walled Carbon Nanotube/Nylon-6 Nanofiber Composites and Investigation of their Gas Sensing Ability

    PubMed Central

    Lala, Neeta L.; Thavasi, Velmurugan; Ramakrishna, Seeram

    2009-01-01

    We have prepared electrospun Nylon-6 nanofibers via electrospinning, and adsorbed multi-walled carbon nanotubes (MWCNTs) onto the surface of Nylon-6 fibers using Triton® X-100 to form a MWCNTs/Nylon-6 nanofiber composite. The dispersed MWCNTs have been found to be stable in hexafluoroisopropanol for several months without precipitation. A MWCNTs/Nylon-6 nanofiber composite based chemical sensor has demonstrated its responsiveness towards a wide range of solvent vapours at room temperature and only mg quantities of MWCNTs were expended. The large surface area and porous nature of the electrospun Nylon-6/MWCNT nanofibers facilitates greater analyte permeability. The experimental analysis has indicated that the dipole moment, functional group and vapour pressure of the analytes determine the magnitude of the responsiveness. PMID:22389589

  14. Tibetan Apples and Oranges: Surficial Sutures and Overlapping Lithospheres

    NASA Astrophysics Data System (ADS)

    Chen, W. P.; Hung, S. H.; Wang, C. Y.; Tseng, T. L.

    2014-12-01

    Multi-scale, finite-frequency tomography across the Himalayas-Tibet shows a clear, subhorizontal anomaly of high VP and VSin the upper mantle that can be traced from under N. India all the way to beneath central Tibet. This configuration of the "Greater India" (GI), or the submerged, northern portion of the Indian shield, is combined with other constraints to reconstruct position of the Indian lithospheric mantle (ILM) relative to Asia back to about 15 Ma ago, or the onset of the latest magmatic activity in Tibet. By then, the leading edge of the ILM (Indian mantle front, IMF) has advanced subhorizontally past the entire Lhasa terrane and also probably have caused the lithospheric mantle beneath the Qiangtang terrane to thicken. The thickening is likely to have led to Rayleigh-Taylor instability, causing widespread but small volume of magmatic activity in northern Tibet. Meanwhile, the detached lithospheric mantle foundered through the upper mantle to rest at the bottom of the mantle transition zone (MTZ), just above the lower mantle. This detached lithospheric mantle manifests itself as a large-scale seismic anomaly of high compressional wave speed (VP) but curiously is undetectable through shear-waves. Based on laboratory data for nominally anhydrous olivine and its high-pressure polymorphs (NAO), the discordant results between P- and S-waves is explained by abundant hydroxyls in the foundered lithospheric mantle, a hypothesis supported by other evidences as well. Since NAO can hold ~1 wt% of water throughout the upper mantle and the MTZ, foundering of thickened lithospheric mantle caused by continental collision is an under-appreciated but effective pathway for water to enter the deep mantle. Currently, the Indus-Yarlung suture between northern India and the Lhasa terrane appears to be an inactive, crustal feature, as the GI continues to pass beneath it. On the other hand, even though the IMF has now advanced northward beyond the Bangong-Nujiang suture (BNS

  15. Microbiology of Explanted Suture Segments from Infected and Noninfected Surgical Patients

    PubMed Central

    Krepel, Candace J.; Marks, Richard M.; Rossi, Peter J.; Sanger, James; Goldblatt, Matthew; Graham, Mary Beth; Rothenburger, Stephen; Collier, John; Seabrook, Gary R.

    2013-01-01

    Sutures under selective host/environmental factors can potentiate postoperative surgical site infection (SSI). The present investigation characterized microbial recovery and biofilm formation from explanted absorbable (AB) and nonabsorbable (NAB) sutures from infected and noninfected sites. AB and NAB sutures were harvested from noninfected (70.9%) and infected (29.1%) sites in 158 patients. At explantation, devices were sonicated and processed for qualitative/quantitative bacteriology; selective sutures were processed for scanning electron microscopy (SEM). Bacteria were recovered from 85 (53.8%) explanted sites; 39 sites were noninfected, and 46 were infected. Suture recovery ranged from 11.1 to 574.6 days postinsertion. A significant difference in mean microbial recovery between noninfected (1.2 isolates) and infected (2.7 isolates) devices (P < 0.05) was noted. Staphylococcus epidermidis, Staphylococcus aureus, coagulase-negative staphylococci (CNS), Peptostreptococcus spp., Bacteroides fragilis, Escherichia coli, Enterococcus spp., Pseudomonas aeruginosa, and Serratia spp. were recovered from infected devices, while commensal skin flora was recovered from noninfected devices. No significant difference in quantitative microbial recovery between infected monofilament and multifilament sutures was noted. Biofilm was present in 100% and 66.6% of infected and noninfected devices, respectively (P < 0.042). We conclude that both monofilament and braided sutures provide a hospitable surface for microbial adherence: (i) a significant difference in microbial recovery from infected and noninfected sutures was noted, (ii) infected sutures harbored a mixed flora, including multidrug-resistant health care-associated pathogens, and (iii) a significant difference in the presence or absence of a biofilm in infected versus noninfected explanted devices was noted. Further studies to document the benefit of focused risk reduction strategies to minimize suture contamination and

  16. Ultrasonography in the evaluation of the mid-palatal suture in rapid palatal expansion

    PubMed Central

    Gumussoy, I; Bayrakdar, I S; Dagistan, S; Caglayan, F

    2014-01-01

    Objectives: Orthodontists usually evaluate the mid-palatal sutural opening with occlusal radiography. The purpose of this article is to evaluate the sutural opening with ultrasonography (USG) in a series of patients undergoing rapid palatal expansion (RPE). Methods: The study included 87 USG images and 87 occlusal radiographs from 29 healthy patients (mean age, 13.9 years; range, 11–20 years; boys, 12; girls, 17) who required RPE treatment. The sutural opening was assessed with USG, and the amount of sutural expansion as mesiodistal length was measured immediately after appliance practice (T0), 10 turns (T1) and 20 turns (T2) during the expansion period. Sutural expansion evaluated by occlusal radiographs was scored at every stage. Measurements obtained by USG and scores observed in the occlusal radiographs were compared by non-parametric Kendall's tau test. Results: Both USG and radiographic images revealed normal anatomical structure during pre-expansion (stage T0). On USG, sutural expansion was seen in 19 patients at stage T1. There was no expansion at this stage in ten patients. At stage T2, on USG and radiography, an increase in the amount of expansion was observed in 19 patients with sutural expansion at stage T1 and sutural expansion was observed in 5 patients without sutural expansion at stage T1. No expansion was observed at both stages T1 and T2 in five patients. USG measurements and occlusal scores in both T1 and T2 turns showed statistically significant correlation (p < 0.001). Conclusions: The results indicate that USG might be a useful method to assess mid-palatal sutural opening in patients undergoing RPE. PMID:25168810

  17. Biomechanical evaluation of suture holding properties of native and tissue engineered articular cartilage

    PubMed Central

    DuRaine, GD; Arzi, B; Lee, JK; Lee, CA; Responte, DJ; Hu, JC; Athanasiou, KA

    2014-01-01

    Objective The purpose of this study was to determine suture-holding properties of tissue engineered neocartilage relative to native articular cartilage. To this end, suture pull-out strength was quantified for native articular cartilage and for neocartilages possessing various mechanical properties. Methods Suture holding properties were examined in vitro and in vivo. Neocartilage from bovine chondrocytes was engineered using two sets of exogenous stimuli resulting in neotissue of different biochemical compositions. Compressive and tensile properties and glycosaminoglycan, collagen, and pyridinoline cross-link contents were assayed (study 1). Suture pull-out strength was compared between neocartilage constructs, and bovine and leporine native cartilage. Uniaxial pull-out test until failure was performed after passing 6-0 Vicryl through each tissue (study 2). Subsequently, neocartilage was implanted into a rabbit model to examine short-term suture holding ability in vivo (study 3). Results Neocartilage glycosaminoglycan and collagen content per wet weight reached 4.55% ± 1.62% and 4.21 ± 0.77%, respectively. Tensile properties for neocartilage constructs reached 2.6 ± 0.77 MPa for Young’s modulus and 1.39 ± 0.63 MPa for ultimate tensile strength. Neocartilage reached ~33% of suture pull-out strength of native articular cartilage. Neocartilage cross-link content reached 50% of native values, and suture pull-out strength correlated positively with cross-link content (R2=0.74). Neocartilage sutured into rabbit osteochondral defects was successfully maintained for 3 weeks. Conclusion This study shows that pyridinoline cross-links in neocartilage may be vital in controlling suture pull-out strength. Neocartilage produced in vitro with one-third of native tissue pull-out strength appears sufficient for construct suturing and retention in vivo. PMID:24848644

  18. CFD Analysis of Coolant Flow in VVER-440 Fuel Assemblies with the Code ANSYS CFX 10.0

    SciTech Connect

    Toth, Sandor; Legradi, Gabor; Aszodi, Attila

    2006-07-01

    From the aspect of planning the power upgrading of nuclear reactors - including the VVER-440 type reactor - it is essential to get to know the flow field in the fuel assembly. For this purpose we have developed models of the fuel assembly of the VVER-440 reactor using the ANSYS CFX 10.0 CFD code. At first a 240 mm long part of a 60 degrees segment of the fuel pin bundle was modelled. Implementing this model a sensitivity study on the appropriate meshing was performed. Based on the development of the above described model, further models were developed: a 960 mm long part of a 60-degree-segment and a full length part (2420 mm) of the fuel pin bundle segment. The calculations were run using constant coolant properties and several turbulence models. The impacts of choosing different turbulence models were investigated. The results of the above-mentioned investigations are presented in this paper. (authors)

  19. Uterine artery suture: a preventive approach for pernicious placenta previa.

    PubMed

    Du, Xiaodong; Xie, Xiaoe; Wang, Yi

    2014-03-01

    Pernicious placenta previa is an obstetric complication that results in a crisis situation for many patients. Most existing options deal with the problems after delivery leading to unfavorable outcomes. To circumvent this situation, a few preventive simple surgical options have been discussed in this paper. The highlight of the approach is the application of ascending uterine artery suture that drastically reduced the amount of bleeding as compared to that observed in regular surgeries. Combined with the placenta accrete location, wedge resection and 'patch' homeostasis of the serous membrane, the surgical modifications adopted effectively reduced the need for hysterectomy thus preserving the fertility of the patients for the future. Since fetuses were safely removed within 1-2 min, the Apgar scores of the neonates were also largely unaffected. PMID:23949849

  20. An accessory skull suture mimicking a skull fracture.

    PubMed

    Wiedijk, J E F; Soerdjbalie-Maikoe, V; Maat, G J R; Maes, A; van Rijn, R R; de Boer, H H

    2016-03-01

    This paper describes an investigation of the sudden and unexpected death of a five-and-a-half-month-old boy. As in every Dutch case of sudden unexpected death in infancy (SUDI), a multidisciplinary diagnostic approach was used. This included post-mortem radiography, showing a linear discontinuity of the parietal bone. Originally this was interpreted as a skull fracture, but autopsy indicated no signs of mechanical trauma. Instead the defect was defined as a unilateral accessory suture of the parietal bone. The initial erroneous diagnosis had severe adverse consequences and thus every health care professional or forensic specialist dealing with paediatric mechanical traumas should be cautious of this rare anomaly. PMID:26860068

  1. Identification of IGF-I in the calvarial suture of young rats: histochemical analysis of the cranial sagittal sutures in a hyperthyroid rat model.

    PubMed

    Akita, S; Hirano, A; Fujii, T

    1996-01-01

    Premature closure of cranial sutures has been known as one of the complications of juvenile or congenital hyperthyroidism. Thyroid hormone is an anabolic agent for bone formation in the early stages of childhood development. In children, excess thyroid hormone acts as an acceleration factor for the skeletal bone, whereas in adult hyperthyroidism, it causes bone mineral loss due to the high turnover rate of bone formation and consequently bone resorption. In addition, there are numerous literature descriptions concerning the interactions among bone metabolism, hormones, and growth factors, among which insulin-like growth factor I (IGF-I) is the most abundantly found growth factor in osteoblasts and in bone models in vivo. We therefore investigated whether or not the cranial sutures show accelerated closure and how the local growth factors or cytokines participate and function in local bone metabolism after administration of exogenous excess thyroid hormone in a rat model. A total of 60 female Wistar rats, aged 10 days, were divided into two groups, the triiodothyronine (T3)-treated group (n = 30, T3 0.1 microgram/gm of body weight per day) and the control group (n = 30, saline vehicle only), and were maintained and subsequently sacrificed at 15, 30, and 60 days. The parameters of cranial width derived from the morphologic measurements of the skull indicated that the lambda-asterion distance at 30 days and the pterion-bregma distance at 60 days in the T3-treated group were significantly decreased compared with those of the control group. Furthermore, the fluorescent histologic findings showed fluorescent labeling with no interruption along the suture edges, suggesting continuous bone formation, and displayed narrowing of the suture gap of the sagittal suture in the T3-treated group. Tartrate resistant acid phosphatase staining showed very little osteoclastic activity in the sagittal suture, especially in the T3-treated group. The intensity of immunohistochemical

  2. Effects of pressure, oxygen concentration, and forced convection on flame spread rate of Plexiglas, Nylon and Teflon

    NASA Technical Reports Server (NTRS)

    Notardonato, J. J.; Burkhardt, L. A.; Cochran, T. H.

    1974-01-01

    Experiments were conducted in which the burning of cylindrical materials in a flowing oxidant stream was studied. Plexiglas, Nylon, and Teflon fuel specimens were oriented such that the flames spread along the surface in a direction opposed to flowing gas. Correlations of flame spread rate were obtained that were power law relations in terms of pressure, oxygen concentration, and gas velocity.

  3. The effects of the conditions of char formation on the physical properties of charred phenolic-nylon

    NASA Technical Reports Server (NTRS)

    Smyly, E. D.; Pears, C. D.

    1972-01-01

    A study was made of the effects of the conditions of char formation on the physical properties of charred phenolic nylon of 0.577 gm/cu cm density. It was found that the thermal conductivity and several of the monitors correlate well with degradation conditions. The monitors included electrical resistivity, sonic velocity, porosity, lattice spacing and crystallite size.

  4. The Cyclohexanol Cycle and Synthesis of Nylon 6,6: Green Chemistry in the Undergraduate Organic Laboratory

    ERIC Educational Resources Information Center

    Dintzner, Matthew R.; Kinzie, Charles R.; Pulkrabek, Kimberly; Arena, Anthony F.

    2012-01-01

    A one-term synthesis project that incorporates many of the principles of green chemistry is presented for the undergraduate organic laboratory. In this multistep scheme of reactions, students react, recycle, and ultimately convert cyclohexanol to nylon 6,6. The individual reactions in the project employ environmentally friendly methodologies, and…

  5. The role of graft materials in suture augmentation for tendon repairs and reattachment.

    PubMed

    Kummer, Frederick J; Iesaka, Kazuho

    2005-08-01

    Various biomaterials have been used to augment sutures for the repair and reattachment of tendons. This study examined four different graft materials in a simple and reproducible model using chicken Achilles tendons to determine the strength and mechanism of suture reinforcement of tendon repairs. The graft materials tested were Gore-Tex(R) Soft Tissue Patch, Graftjacket, bovine pericardium, and an experimental graft material from Xylos Corporation. Testing was performed in shear to simulate forces on a torn tendon repair and pull-off to simulate those on a tendon reattachment to bone. Compared to unaugmented suture, grafts increased suture fixation strength from 10% to 60% in shear and from 0% to 36% in pull-off with the bovine pericardium graft, providing significant improvement in both tests. In no cases (even unaugmented) did the suture pull directly through the tendon, but instead sliced along it, demonstrating that the interface between the suture and the tendon determines fixation strength. Grafts function by increasing the area, friction, and nature of this interface, not by acting as a barrier for suture pull-through. PMID:15981174

  6. Enhanced Zone II Flexor Tendon Repair through a New Half Hitch Loop Suture Configuration

    PubMed Central

    Thomopoulos, Stavros; Gelberman, Richard H.

    2016-01-01

    This study evaluated the impact of a new half hitch loop suture configuration on flexor tendon repair mechanics. Cadaver canine flexor digitorum profundus tendons were repaired with 4- or 8-strands, 4–0 or 3–0 suture, with and without half hitch loops. An additional group underwent repair with half hitch loops but without the terminal knot. Half hitch loops improved the strength of 8-strand repairs by 21% when 4–0, and 33% when 3–0 suture was used, and caused a shift in failure mode from suture pullout to suture breakage. 8-strand repairs with half hitch loops but without a terminal knot produced equivalent mechanical properties to those without half hitch loops but with a terminal knot. 4-strand repairs were limited by the strength of the suture in all groups and, as a result, the presence of half hitch loops did not alter the mechanical properties. Overall, half hitch loops improved repair mechanics, allowing failure strength to reach the full capability of suture strength. Improving the mechanical properties of flexor tendon repair with half hitch loops has the potential to reduce the postoperative risk of gap formation and catastrophic rupture in the early postoperative period. PMID:27101409

  7. BCL11B expression in intramembranous osteogenesis during murine craniofacial suture development

    PubMed Central

    Holmes, Greg; van Bakel, Harm; Zhou, Xueyan; Losic, Bojan; Jabs, Ethylin Wang

    2014-01-01

    Sutures, where neighboring craniofacial bones are separated by undifferentiated mesenchyme, are major growth sites during craniofacial development. Pathologic fusion of bones within sutures occurs in a wide variety of craniosynostosis conditions and can result in dysmorphic craniofacial growth and secondary neurologic deficits. Our knowledge of the genes involved in suture formation is poor. Here we describe the novel expression pattern of the BCL11B transcription factor protein during murine embryonic craniofacial bone formation. We examined BCL11B protein expression at E14.5, E16.5, and E18.5 in 14 major craniofacial sutures of C57BL/6J mice. We found BCL11B expression to be associated with all intramembranous craniofacial bones examined. The most striking aspects of BCL11B expression were its high levels in suture mesenchyme and increasingly complementary expression with RUNX2 in differentiating osteoblasts during development. BCL11B was also expressed in mesenchyme at the non-sutural edges of intramembranous bones. No expression was seen in osteoblasts involved in endochondral ossification of the cartilaginous cranial base. BCL11B is expressed to potentially regulate the transition of mesenchymal differentiation and suture formation within craniofacial intramembranous bone. PMID:25511173

  8. Application of modified reverse panoramic radiograph on lambdoid suture for age estimation

    PubMed Central

    Dwivedy, Shweta; Sah, Kunal; Sinha, Shruti

    2015-01-01

    Background Cranial suture closure has long been recognized as a character of human development related to aging. For this reason, it has been utilized for various forensic and archaeological studies to determine the age of an unidentified/or skeletonized individuals. Various cadaveric studies have established the role of lambdoid suture in age estimation, but not routinely practiced. The objective is to establish if any correlation exists between individual’s age and lambdoid sutures closure status (ectocranially) in mortals through modified reverse panoramic radiograph (RPRg). Methods Total number of 85 subjects, 25 years and beyond were included in the study, and divided into four groups with an age interval of 10 years. Assessment of lambdoid suture closure was done according to Frederic Rating Scale on modified RPRg. Data obtained was subjected to statistical analysis using Spearman’s correlation test. Results A significant difference was observed between the age group and suture closure. Correlation coefficient of 0.570 was obtained, and was interpreted as a good correlation between the age and suture closure status with a P value of <0.001. Conclusions Lambdoid suture can be very effective and practical tool for age assessment in mortals through modified RPRg (ectocranially). PMID:26435915

  9. FGFR2c-mediated ERK-MAPK activity regulates coronal suture development.

    PubMed

    Pfaff, Miles J; Xue, Ke; Li, Li; Horowitz, Mark C; Steinbacher, Derek M; Eswarakumar, Jacob V P

    2016-07-15

    Fibroblast growth factor receptor 2 (FGFR2) signaling is critical for proper craniofacial development. A gain-of-function mutation in the 2c splice variant of the receptor's gene is associated with Crouzon syndrome, which is characterized by craniosynostosis, the premature fusion of one or more of the cranial vault sutures, leading to craniofacial maldevelopment. Insight into the molecular mechanism of craniosynostosis has identified the ERK-MAPK signaling cascade as a critical regulator of suture patency. The aim of this study is to investigate the role of FGFR2c-induced ERK-MAPK activation in the regulation of coronal suture development. Loss-of-function and gain-of-function Fgfr2c mutant mice have overlapping phenotypes, including coronal synostosis and craniofacial dysmorphia. In vivo analysis of coronal sutures in loss-of-function and gain-of-function models demonstrated fundamentally different pathogenesis underlying coronal suture synostosis. Calvarial osteoblasts from gain-of-function mice demonstrated enhanced osteoblastic function and maturation with concomitant increase in ERK-MAPK activation. In vitro inhibition with the ERK protein inhibitor U0126 mitigated ERK protein activation levels with a concomitant reduction in alkaline phosphatase activity. This study identifies FGFR2c-mediated ERK-MAPK signaling as a key mediator of craniofacial growth and coronal suture development. Furthermore, our results solve the apparent paradox between loss-of-function and gain-of-function FGFR2c mutants with respect to coronal suture synostosis. PMID:27034231

  10. A method for impregnating nylon transfer membranes with leucocrystal violet for enhancing and lifting bloody impressions.

    PubMed

    Michaud, Amy L; Brun-Conti, Leanora

    2004-05-01

    The objective of this research project was to demonstrate a quick and easy method for impregnating nylon transfer membranes with leucocrystal violet (LCV) for the purpose of lifting and enhancing impressions made in blood. A stamp that would simulate fine detail found in fingerprints or footwear was used to create impressions on a variety of substrates. Four different LCV formulations were tested to determine the effectiveness of the prepared membranes in lifting and enhancing the impressions. Further investigation involved the feasibility of using the LCV membranes in the field by studying the shelf life and storage of the impregnated membranes and the longevity of the lifted impressions. One of the formations studied demonstrated superior lifting and enhancing capabilities, as well as a prolonged shelf life and a resilience of the lifted impressions, thus proving LCV to be an extremely valuable technique. PMID:15171168

  11. The nylon column dye test: a possible screening test of phagocyte function.

    PubMed

    Segal, A W; Peters, T J

    1975-12-01

    1. A simple quantitative test has been developed to investigate phagocyte function. 2. This test is performed by the addition of Nitroblue Tetrazolium to whole blood, followed by the isolation of leucocytes on a column of nylon wool. Dye reduction by phagocytes is apparent as a blue coloration of the column due to the formation of formazan. The formazan can be extracted from the column and measured spectrophotometrically. 3. The formation of formazan was found to be directly related to the number of phagocytes in blood. 4. Two patients with chronic granulomatous disease gave abnormal results, suggesting that the test procedure may be of value as a screening procedure for this disease. PMID:1106938

  12. Effect of moisture absorption on the impact behavior of unidirectional carbon fiber reinforced nylon 6 composite

    SciTech Connect

    Lin, C.W.

    1993-12-31

    The impact behaviors of carbon fiber reinforced nylon 6(CF/PA6) composite at various levels of moisture absorption have been investigated and the fracture behaviors were characterized by scanning electron microscopy. Both impact strength and impact resistance of the CF/PA6 composite were found to have decreased with an increasing moisture absorption as the laminate was annealed from melt. For the fast-cooled specimens, a small amount of moisture (less than 2.1 wt %) was advantageous to the impact properties as compared with the dried laminate; it, however, became detrimental as the moisture intake got higher. A competition of crack-tip blunting, fiber-matrix interfacial strength and plasticization-caused variation of stiffness was proposed to interpret the experimental results.

  13. Cyclic fatigue behaviour of fibre reinforced rubber-toughened nylon composite materials

    NASA Astrophysics Data System (ADS)

    Pinot, L.; Gomina, M.; Jernot, J.-P.; Moreau, R.; Nakache, E.

    2005-03-01

    The effects of the amount of rubber, the concentration of fibres and the state of the fibre/matrix interface upon the mechanical behaviour of glass fibre/rubber-toughened nylon ternary blends are checked. First, monotonic tensile tests were carried out on different intermediate materials and then on the ternary blends to derive the stress-strain curves and document the damage mechanisms. Cyclic fatigue tests were implemented on tensile specimens and the results were analysed in terms of the reduction of the Young's modulus, the increase of the hysteresis energy rate in the stress-strain diagram and the temperature rise. These findings were correlated to fractographic observations to assess the role of the different constituents.

  14. Unpolarized and polarized Raman spectroscopy of nylon-6 polymorphs: a quantum chemical approach.

    PubMed

    Milani, Alberto

    2015-03-01

    Exploiting the very recent potentialities of state-of-the-art quantum chemical simulations of crystalline solids, unpolarized Raman spectra of α and γ polymorphs of Nylon-6 obtained through periodic density functional theory calculations are presented for the first time. The computed spectra are compared with the experimental spectra reported in the literature and allow a detailed interpretation to be proposed of the patterns observed, identifying unambiguous Raman marker bands of the different phases. The calculations of single crystal directional intensities gave the further possibility to predict the polarization properties of the Raman spectra of these polymorphs: considering in particular the α phase, polarized Raman spectra have been computed and showed a very good agreement with measurements previously reported for uniaxially oriented samples. PMID:25686634

  15. Physicochemical characterization of chitosan/nylon6/polyurethane foam chemically cross-linked ternary blends

    NASA Astrophysics Data System (ADS)

    Jayakumar, S.; Sudha, P. N.

    2013-03-01

    Chitosan/nylon6/polyurethane foam (CS/Ny6/PUF) ternary blend was prepared and chemically cross-linked with glutaraldehyde. Structural, thermal and morphological studies were performed for the prepared ternary blends. Characterizations of the ternary blends were investigated by Fourier transform infrared spectroscopy (FTIR), thermo gravimetric analysis (TGA), differential scanning calorimetry (DSC), X-ray diffraction (XRD) and scanning electron microscope (SEM). The FTIR results showed that the strong intermolecular hydrogen bonds took place between CS, Ny6 and PUF. TGA and DSC studies reveal that the thermal stability of the blend is enhanced by glutaraldehyde as crosslinking agent. Results of XRD indicated that the relative crystalline of pure CS film was reduced when the polymeric network was reticulated by glutaraldehyde. Finally, the results of scanning electron microscopy (SEM) indicated that the morphology of the blend is rough and heterogeneous, further it confirms the interaction between the functional groups of the blend components.

  16. Data on the growth of ZnO nanorods on Nylon 6 and photocatalytic activity.

    PubMed

    Ummartyotin, S; Tangnorawich, B

    2016-09-01

    ZnO was successfully synthesized by a conventional synthetic route using zinc nitrate as a source for ZnO formation. X-ray diffraction and thermogravimetric analysis revealed a crystal size of 66 nm of ZnO and a thermal stability of 500 °C. A small amount of ZnO particles was employed as the source for ZnO-rod growth on nylon 6 surfaces. Scanning electron microscope images were taken to evaluate the morphological properties of ZnO, which presented as a hexagonal needle-like shape. Preliminary evaluation of photocatalytic activity was performed through measurement of the degradation of methylene blue solution over 4 h. PMID:27437437

  17. Analysis of Glass-Filled Nylon in Laser Powder Bed Fusion Additive Manufacturing

    NASA Astrophysics Data System (ADS)

    Slotwinski, John; LaBarre, Erin; Forrest, Ryan; Crane, Emily

    2016-03-01

    At the Johns Hopkins University Applied Physics Laboratory (APL), glass bead-filled polyamide (a.k.a. nylon) (GFN) is being used frequently for functional parts and systems, built using a laser-based powder bed fusion (PBF) additive manufacturing (AM) system. Since these parts have performance requirements, it is important to understand the mechanical properties of the additively-made GFN as a function of build orientation and build parameters. In addition, the performance of the AM system used to manufacture these parts must be evaluated in order to understand its capabilities, especially in order to determine the dimensional precision and repeatability of features built with this system. This paper summarizes recent APL efforts to characterize the GFN powder, the mechanical properties of parts made with GFN, and the performance of the laser PBF machine while running GFN using an AM test artifact.

  18. Nylon 6.6 accelerated aging studies : thermal-oxidative degradation and its interaction with hydrolysis.

    SciTech Connect

    Bernstein, Robert; Derzon, Dora Kay; Gillen, Kenneth T.

    2004-06-01

    Accelerated aging of Nylon 6.6 fibers used in parachutes has been conducted by following the tensile strength loss under both thermal-oxidative and 100% relative humidity conditions. Thermal-oxidative studies (air circulating ovens) were performed for time periods of weeks to years at temperatures ranging from 37 C to 138 C. Accelerated aging humidity experiments (100% RH) were performed under both an argon atmosphere to examine the 'pure' hydrolysis pathway, and under an oxygen atmosphere (oxygen partial pressure close to that occurring in air) to mimic true aging conditions. As expected the results indicated that degradation caused by humidity is much more important than thermal-oxidative degradation. Surprisingly when both oxygen and humidity were present the rate of degradation was dramatically enhanced relative to humidity aging in the absence of oxygen. This significant and previously unknown phenomena underscores the importance of careful accelerated aging that truly mimics real world storage conditions.

  19. New Method of Age Estimation from Maxillary Sutures Closure in a Thai Population.

    PubMed

    Sinthubua, A; Theera-Umpon, N; Auephanwiriyakul, S; Ruengdit, S; Das, S; Mahakkanukrauh, P

    2016-01-01

    Age estimation is one of the major components of forensic identification. Cranial suture closure has long been used as indicator for age estimation. Maxillary sutures have been less studied for estimation of age at death because they vary in their timing of closure with age. The purpose of this study was to estimate age by examining 190 Thai skulls with age ranging between 15-93 years from Forensic Osteology Research Center, Faculty of Medicine, and Chiang Mai University. Four parts of maxillary suture (incisive, anterior, transverse, and posterior sutures) were investigated the suture obliteration of each suture by computerizing from photograph. The suture were measured by pixel counting.The prediction model which based on the support vector machine (SVM) for regression or support vector regression (SVR) was utilized for data analysis. The results showed high correlation (R2 = 0.9086) between the predicted age and actual age. Plot between actual age group and predicted age in seven groups also revealed high correlation (R2 = 0.9434). These can be implied that we are able to use this SVR model to predict age at death using maxillary suture information.The interesting issue is to further apply this model in more cases to ensure the generalization of the finding. This study is the first attempt to estimate age at death using a new method based on novel analysis which considers a characteristic of relationship between maxillary suture closures with age that are not in linear form. The present study may contribute as a basis knowledge and method for further study of age estimation in archaeological and forensic anthropological contexts, especially when only skull or base of skull are found. PMID:27212570

  20. Nylon-Based Affinity Membranes: Impacts of Surface Modification on Protein Adsorption.

    PubMed

    Beeskow; Kroner; Anspach

    1997-12-15

    Nylon microfiltration membranes were activated with bisoxirane and formaldehyde at terminal amino groups and amide groups of the nylon polymer, respectively. Dextrans were covalently immobilized on these activated membranes to yield dextran-coated membrane matrices. Both procedures led to a significant reduction of hemoglobin adsorption; however, bisoxirane activation required additional cross-linking of dextran and a second dextran layer to yield comparable quality of dextran-coated membranes than formaldehyde activation. Formaldehyde activation was easiest and cheapest and resulted in membranes with highest dextran density and relatively lowest nonspecific hemoglobin adsorption. Dextrans of &Mmacr;w >/= 40,000 were required for bisoxirane-activated membranes, whereas dextrans of &Mmacr;w = 6000 were sufficient for formaldehyde-activated membranes. Both activation methods resulted in stable coatings at low and high pH; however, formaldehyde-activated membranes were unstable under strongly acidic conditions at pH < 3. Dextran coils were found responsible for the reduction of the hydraulic permeability but also for the high ligand densities obtained after immobilization of Cibacron Blue F3G-A (360 nmol/cm2) and iminodiacetic acid (400 nmol/cm2). The thermodynamics of protein adsorption on dye ligand affinity (DLA) membranes corresponded with chromatographic sorbents and dye ligand conjugates, with the dextran coating demonstrating similar structure than dextrans in solution. Protein adsorption took place in the extended coil structure of dextrans with binding capacities up to 730 µg/cm2 lysozyme on DLA membranes and 470 µg/cm2 concanavalin A on metal chelate affinity membranes. Copyright 1997 Academic Press. PMID:9792753

  1. Laser welding of nylon thin films using a pulsed CO2 waveguide laser

    NASA Astrophysics Data System (ADS)

    Villagomez, R.; Valenzuela, Rogelio; Camacho-Mesa, Roxana B.

    2011-10-01

    In this work, we present an experimental investigation for welding Nylon: Bi-Oriented Polyamide (BOPA) thin films using a CO2 waveguide laser in a pulsed configuration. The material used in this study is Nylon 6, all set in square sheet thin films samples of 100 cm2 with 15 µm thickness. Our optical setup is based on deliver the laser beam all the way through the work piece using X-Y scanning mirrors mounted on galvo-like motors and an f-theta lens with 15 cm focal length and 50 µm focal spot sizes. The fluence (laser energy) is controlled by a pulse signal generator having the possibility to change the pulse repetition rate (PRR) and the pulse width (PW) of the laser beam. Our results show the best weld seam for scanning speeds of 20mm/s and the pulsed laser beam with 2 KHz PRR and 80 µs for the PW time. The scanning speed and trajectory for the welding process are all controlled by a computer in which one can modify the weld parameters. The irradiance at the focal point is set to 1.146 MW/cm2 while the average optical power was set to 22.5W. Our experimental parameters are previously modeled by using COMSOL Multiphysics software were the laser heat source is modeled on the selected material. This model is based on the heat transfer partial differential equation and solved by finite elements procedure. Model results show a perfect agreement with the experiments. Finally, the quality of the welded seam is studied by means of sealed tight and share force critical mechanical test.

  2. Experimental investigation of transport of discrete solids with surge flows in a 10.0 cm diameter partially filled pipe

    NASA Astrophysics Data System (ADS)

    Mahajan, B. M.

    1982-01-01

    The transport of discrete solids with surge flows in a partially filled slightly pitched horizontal pipe was investigated. The experimental apparatus, instrumentation, and procedures are described. The experiments were conducted using a cylindrical solid in a 10.0 cm (4 in) diameter pipe. The water surge flows were obtained by discharging different volumes of water into the pipe from a falling head open container which simulated a water closet. Flow induced solid velocities and stream depth histories at various locations along the length of the pipe were measured. The effects of water volume used, pipe slope, and size of the solid on the solid velocities were examined. Solid velocities were compared with the maximum water velocities estimated from the stream depth histories. Also, the distance traversed by the solids in the pipe were measured for those cases in which the solids did not clear the pipe. The solid velocity increased with an increase in water volume used, a decrease in the size of the solid, and an increase in the pipe slope. The solid velocity in the initial reach of the pipe was less than the maximum water velocity; and the solid velocity approaches the maximum water velocity as the solid traveled downstream, except for some experiments with small water volumes.

  3. Needle infusion avoids using sutures and prevents hypotony in the 23 gauge sutureless vitrectomy

    PubMed Central

    Zhang, Yingjie; Zhu, Dongqing; Zhou, Jibo

    2015-01-01

    Objective: To investigate the effects of needle infusion on preventing wound leakage and hypotony in sutureless vitrectomy. Methods: We retrospectively reviewed 230 consecutive eyes of 23-gauge pars plana vitrectomy with or without needle infusion, and further measured the wound leakage and intraocular pressure (IOP) without using a suture. Results: In the eyes with primary needle infusion inserted before infusion cannula removal, IOP was stable during and after infusion cannula removal. No suture was needed in the procedure. Postoperative hypotony did not occurred in all eyes with needle infusion either. Conclusion: Needle infusion inserted before infusion cannula removal can avoid using sutures and prevent hypotony intraoperatively and postoperatively. PMID:26770552

  4. Operating Endoscopically with “Two Hands” to Remove Calcified Permanent Suture After Pyeloplasty

    PubMed Central

    Sweet, Robert M.; Anderson, James Kyle

    2016-01-01

    Abstract We describe a combined percutaneous and endoscopic approach to remove encrusted permanent suture in the renal pelvis that was placed during pyeloplasty repair. Our index patient had a laparoscopic dismembered pyeloplasty at an outside institution 10 years before presenting with flank pain and nondependent nephrolithiasis. This proved to be an encrusted permanent suture material. There is limited data on incidence of nephrolithiasis after ureteropelvic junction repair, but it is well documented that nonabsorbable suture lines should be avoided in the urinary tract as they may serve as a nidus for stone formation.

  5. Tandem suturing and disarticulation of the Taiwan orogen revealed by its neotectonic elements

    NASA Astrophysics Data System (ADS)

    Shyu, J. Bruce H.; Sieh, Kerry; Chen, Yue-Gau

    2005-04-01

    Taiwan's numerous active faults and folds demarcate distinct eastern and western neotectonic belts. The western belt results from the attachment and subsequent detachment of a sliver of continental lithosphere to the Eurasian continental margin. The eastern belt is the product of the same continental sliver docking with and then separating from the Luzon volcanic arc. Thus, the active Taiwan orogen is a tandem suturing and tandem disengagement of a volcanic arc and a continental sliver to and from the Eurasian continental margin. This progressive suturing and separation is a superb, living demonstration of the fundamental weakness of lithospheric sutures. Furthermore, this neotectonic architecture provides the basis for understanding the Taiwan's seismic sources.

  6. [Morphological changes of tissues in formation of a welding suture on the large intestine].

    PubMed

    Bondar', G V; Basheev, V Kh; Borota, A V; Miroshnichenko, E Iu; Koshik, E A

    2011-01-01

    Abdominoanal resection with descending of left colon on perineum, leaving additional part of a descended intestine, was performed. For the hemorrhage arrest the welding sutures were put on intestinal wall. According to morphological investigations data, a damage of intestinal wall in the zone of a welding suture application is a reversible one, it spreads from the electrode branch on 2-3 mm. The presence of undamaged structures witnesses the presence of an active regeneration process in tissues around the welding suture. PMID:21512998

  7. Specialty polymeric membranes. 8: Separation of benzene from benzene/cyclohexane mixtures with nylon 6-graft-poly(butyl methacrylate) membranes

    SciTech Connect

    Yoshikawa, Masakazu; Tsubouchi, Keisuke; Kitao, Toshio

    1999-02-01

    A novel pervaporation membrane was prepared by radical graft polymerization of butyl methacrylate onto nylon 6. The permselectivity toward benzene was increased by the introduction of poly(butyl methacrylate) onto a nylon 6 membrane. From pervaporation and sorption experiments, it was shown that the introduction of poly(butyl methacrylate) onto a nylon 6 membrane leads to the enhancement of permselectivity toward benzene. The solubility data for benzene were described by a combination of simple sorption and specific sorption, while cyclohexane solubility was described by simple sorption.

  8. The suture provides a niche for mesenchymal stem cells of craniofacial bones

    PubMed Central

    Zhao, Hu; Feng, Jifan; Ho, Thach-Vu; Grimes, Weston; Urata, Mark; Chai, Yang

    2015-01-01

    Bone tissue undergoes constant turnover supported by stem cells. Recent studies showed that perivascular mesenchymal stem cells (MSCs) contribute to the turnover of long bones. Craniofacial bones are flat bones derived from a different embryonic origin than the long bones. The identity and regulating niche for craniofacial bone MSCs remain unknown. Here, we identify Gli1+ cells within the suture mesenchyme as the major MSC population for craniofacial bones. They are not associated with vasculature, give rise to all craniofacial bones in the adult and are activated during injury repair. Gli1+ cells are typical MSCs in vitro. Ablation of Gli1+ cells leads to craniosynostosis and arrest of skull growth, indicating these cells are an indispensible stem cell population. Twist1+/− mice with craniosynostosis show reduced Gli1+ MSCs in sutures, suggesting that craniosynostosis may result from diminished suture stem cells. Our study indicates that craniofacial sutures provide a unique niche for MSCs for craniofacial bone homeostasis and repair. PMID:25799059

  9. Timing of cranial suture closure in placental mammals: phylogenetic patterns, intraspecific variation, and comparison with marsupials.

    PubMed

    Rager, Lisa; Hautier, Lionel; Forasiepi, Analía; Goswami, Anjali; Sánchez-Villagra, Marcelo R

    2014-02-01

    Used as markers of postnatal growth closure sequences of 22 ectocranial sutures and synchondroses were recorded in a sample of 1161 skulls belonging to 38 species from all major placental clades: Afrotheria, Xenarthra, Laurasiatheria and Euarchontoglires (Boreoeutheria). The maximum closure level, which is not significantly correlated to body mass, is higher in Afrotheria and Xenarthra than in Boreoeutheria. Only the basioccipito-basisphenoid and the basioccipito-exoccipital synchondroses close in all species sampled, the supraoccipito-exoccipital and the inter-parietal sutures do in most species. Parsimov retrieved more heterochronic shifts for Afrotheria and Xenarthra than for Boreoeutheria. The amount of intraspecific variation differs among the species sampled being high among xenarthran species and low among afrotherians. Specimens (162) representing 12 marsupial genera were also analysed. Placentals exhibit a larger number of suture closures than marsupials and in both groups the sutures at the base of the skull are the first to fuse starting with the basioccipito-exoccipital. PMID:24127274

  10. BCL11B regulates sutural patency in the mouse craniofacial skeleton.

    PubMed

    Kyrylkova, Kateryna; Iwaniec, Urszula T; Philbrick, Kenneth A; Leid, Mark

    2016-07-15

    The transcription factor BCL11B plays essential roles during development of the immune, nervous, and cutaneous systems. Here we show that BCL11B is expressed in both osteogenic and sutural mesenchyme of the developing craniofacial complex. Bcl11b(-/-) mice exhibit increased proliferation of osteoprogenitors, premature osteoblast differentiation, and enhanced skull mineralization leading to synostoses of facial and calvarial sutures. Ectopic expression of Fgfr2c, a gene implicated in craniosynostosis in mice and humans, and that of Runx2 was detected within the affected sutures of Bcl11b(-/-) mice. These data suggest that ectopic expression of Fgfr2c in the sutural mesenchyme, without concomitant changes in the expression of FGF ligands, appears to induce the RUNX2-dependent osteogenic program and craniosynostosis in Bcl11b(-/-) mice. PMID:26453795

  11. Loss of rotator cuff tendon-to-bone interface pressure after reattachment using a suture anchor.

    PubMed

    Brassart, Nicolas; Sanghavi, Sanjay; Hansen, Ulrich N; Emery, Roger J; Amis, Andrew A

    2008-01-01

    The purpose of this study was to examine the tendon-to-bone interface pressure, contact area, and force after reattaching a tendon to bone by use of a suture and suture anchor. Repairs were made in 8 ovine shoulders in vitro, by use of 3 suture types in each: Ethibond, polydioxanone, or Orthocord. A Tekscan pressure sensor was placed between the tendon and bone and monitored for 1 hour after the repair. The principal finding was a significant loss of approximately 60% of the contact parameters immediately after the suture was tied, followed by further significant loss over the next hour to a mean of only 14% of the initial readings. We concluded that pressure measurement systems that only record the initial maximum pressure would yield overly optimistic results for the actual repair pressure after the repair is completed. The Tekscan system, however, allowed us to monitor pressure reductions that occurred both during and after the repair. PMID:18504147

  12. Stem cells of the suture mesenchyme in craniofacial bone development, repair and regeneration

    PubMed Central

    Maruyama, Takamitsu; Jeong, Jaeim; Sheu, Tzong-Jen; Hsu, Wei

    2016-01-01

    The suture mesenchyme serves as a growth centre for calvarial morphogenesis and has been postulated to act as the niche for skeletal stem cells. Aberrant gene regulation causes suture dysmorphogenesis resulting in craniosynostosis, one of the most common craniofacial deformities. Owing to various limitations, especially the lack of suture stem cell isolation, reconstruction of large craniofacial bone defects remains highly challenging. Here we provide the first evidence for an Axin2-expressing stem cell population with long-term self-renewing, clonal expanding and differentiating abilities during calvarial development and homeostastic maintenance. These cells, which reside in the suture midline, contribute directly to injury repair and skeletal regeneration in a cell autonomous fashion. Our findings demonstrate their true identity as skeletal stem cells with innate capacities to replace the damaged skeleton in cell-based therapy, and permit further elucidation of the stem cell-mediated craniofacial skeletogenesis, leading to revealing the complex nature of congenital disease and regenerative medicine. PMID:26830436

  13. Deformation and sedimentation along a developing terrane suture: Eastern Sunda forearc, Indonesia

    SciTech Connect

    Reed, D.L.; Silver, E.A.; Prasetyo, H.; Meyer, A.W.

    1986-12-01

    The collision of the eastern Sunda arc with northwest Australia has resulted in the development of a suture between the Sumba ridge and Sawu-Timor terranes along a zone of intraforearc convergence. The developing suture varies from the low-angle Sawu thrust, with attendant mud diapirs in the Sumba basin, to high-angle reverse faults near a basement high of the underthrust Sumba ridge terrane. Bottom currents, associated with the flow of Pacific Ocean deep water into the Indian Ocean, have eroded the terranes and subsequently deposited the detritus in an assemblage of contourites along the suture. This study reveals the high structural variability of a terrane suture and the oceanographic influence on the deposition of overlap assemblages.

  14. Bioinspired, mechanical, deterministic fractal model for hierarchical suture joints

    NASA Astrophysics Data System (ADS)

    Li, Yaning; Ortiz, Christine; Boyce, Mary C.

    2012-03-01

    Many biological systems possess hierarchical and fractal-like interfaces and joint structures that bear and transmit loads, absorb energy, and accommodate growth, respiration, and/or locomotion. In this paper, an elastic deterministic fractal composite mechanical model was formulated to quantitatively investigate the role of structural hierarchy on the stiffness, strength, and failure of suture joints. From this model, it was revealed that the number of hierarchies (N) can be used to tailor and to amplify mechanical properties nonlinearly and with high sensitivity over a wide range of values (orders of magnitude) for a given volume and weight. Additionally, increasing hierarchy was found to result in mechanical interlocking of higher-order teeth, which creates additional load resistance capability, thereby preventing catastrophic failure in major teeth and providing flaw tolerance. Hence, this paper shows that the diversity of hierarchical and fractal-like interfaces and joints found in nature have definitive functional consequences and is an effective geometric-structural strategy to achieve different properties with limited material options in nature when other structural geometries and parameters are biologically challenging or inaccessible. This paper also indicates the use of hierarchy as a design strategy to increase design space and provides predictive capabilities to guide the mechanical design of synthetic flaw-tolerant bioinspired interfaces and joints.

  15. Peripunctal "anchor" suture for securing the silicone bicanalicular stent in the repair of canalicular lacerations.

    PubMed

    Benger, Ross S; Nemet, Arie Y

    2008-01-01

    We used punctal absorbable suture in 8 patients (8 eyes) for silicone stent stabilization in canalicular repair surgery to prevent the postoperative complication of "cheese-wiring." Postoperatively there was 1 case of cheese-wiring of the repaired canaliculus, and no other complication related to the bicanalicular stent. The pericanalicular "anchor" suture may reduce the incidence of cheese-wiring by silicone bicanalicular stents after repair of canalicular lacerations or resections for stenosis. PMID:18209644

  16. An Alternative Bundle-to-Bundle Suturing Technique for Repairing Fresh Achilles Tendon Rupture.

    PubMed

    Zhao, Jingjing; Yu, Bin; Xie, Ming; Huang, Ruokun; Xiao, Kai

    2016-01-01

    The main concern about conventional Achilles tendon repair surgical techniques is how to maintain the initial strength of the ruptured Achilles tendon through complicated suturing methods. The primary surgical problem lies in the properties of the soft tissue; the deterioration of the Achilles tendon, especially in its elasticity; and the surface lubricity of the local tissues. In the present study, we describe an innovative bundle-to-bundle suturing method that addresses these potential problems. PMID:26970908

  17. Subsurface geometry of the Siletz-Klamath suture in southwest Oregon from mangnetotelluric imaging

    NASA Astrophysics Data System (ADS)

    Box, S.; Bedrosian, P. A.

    2006-12-01

    Siletzia, a Paleocene to early Eocene basaltic seamount terrane, was sutured onto western North America in Eocene times and comprises the modern forearc basement throughout the Pacific Northwest. The suture zone is mostly obscured by the Cascades Arc. In southwest Oregon, however, it is preserved where previously accreted Mesozoic terranes in the Klamath Moutains overthrust Siletzia. The geometry of this suture at depth, however, is poorly constrained. In summer 2006, long-period (deep-crustal) and broadband (shallow-crustal) magnetotelluric (MT) data were collected along a 200-km profile stretching from the Pacific coast north of Coos Bay, OR to the California border south of Medford, OR, with an average site spacing of 4 km. South of the suture, the profile crosses Franciscan and Great Valley equivalents, arc lavas and sediments of the Western Klamath terrane, ophiolitic mélange of the Rattlesnake Creek terrane, and the Hayfork volcanic arc terrane, ending within the Condry Mountain Window. The data are in general agreement with the NW surface strike of the suture and the Klamath terranes. A smooth regularized two-dimensional inversion of the data resulted in a preliminary model extending to ~ 50 km depth which fits the data and is in accordance with observed surface geology. The imaged subsurface geometry of the Siletzia-Klamath suture is compared to previous potential-field modeling that suggested a thinning wedge of Silitzia has been thrust within the Klamath terranes.

  18. Cranial Suture Closure in Domestic Dog Breeds and Its Relationships to Skull Morphology.

    PubMed

    Geiger, Madeleine; Haussman, Sinah

    2016-04-01

    Bulldog-type brachycephalic domestic dog breeds are characterized by a relatively short and broad skull with a dorsally rotated rostrum (airorhynchy). Not much is known about the association between a bulldog-type skull conformation and peculiar patterns of suture and synchondrosis closure in domestic dogs. In this study, we aim to explore breed-specific patterns of cranial suture and synchondrosis closure in relation to the prebasial angle (proxy for airorhynchy and thus bulldog-type skull conformation) in domestic dogs. For this purpose, we coded closure of 18 sutures and synchondroses in 26 wolves, that is, the wild ancestor of all domestic dogs, and 134 domestic dogs comprising 11 breeds. Comparisons of the relative amount of closing and closed sutures and synchondroses (closure scores) in adult individuals showed that bulldog-type breeds have significantly higher closure scores than non-bulldog-type breeds and that domestic dogs have significantly higher closure scores than the wolf. We further found that the prebasial angle is significantly positively correlated with the amount of closure of the basispheno-presphenoid synchondrosis and sutures of the nose (premaxillo-nasal and maxillo-nasal) and the palate (premaxillo-maxillary and interpalatine). Our results show that there is a correlation between patterns of suture and synchondrosis closure and skull shape in domestic dogs, although the causal relationships remain elusive. Anat Rec, 299:412-420, 2016. © 2016 Wiley Periodicals, Inc. PMID:26995336

  19. Bacterial Biofilms on Implanted Suture Material Are a Cause of Surgical Site Infection

    PubMed Central

    Nistico, Laura; Tower, Irene; Lasko, Leslie-Ann; Stoodley, Paul

    2014-01-01

    Abstract Background: Surgical site infection (SSI) has been estimated to occur in up to 5% of all procedures, accounting for up to 0.5% of all hospital costs. Bacterial biofilms residing on implanted foreign bodies have been implicated as contributing or causative factors in a wide variety of infectious scenarios, but little consideration has been given to the potential for implanted, submerged suture material to act as a host for biofilm and thus serve as a nidus of infection. Methods: We report a series of 15 patients who underwent open Roux-en-Y gastric bypass (with musculofascial closure with permanent, multifilament sutures) who developed longstanding and refractory SSIs in the abdominal wall. Explanted suture material at subsequent exploration was examined for biofilm with confocal laser-scanning microscopy (CLSM) and fluorescence in situ hybridization (FISH). Results: All 15 patients at re-exploration were found to have gross evidence of a “slimy” matrix or dense reactive granulation tissue localized to the implanted sutures. Confocal laser-scanning microscopy revealed abundant biofilm present on all sutures examined; FISH was able to identify the presence of specific pathogens in the biofilm. Complete removal of the foreign bodies (and attendant biofilms) resulted in all cases in cure of the SSI. Conclusion: Bacterial biofilms on implanted suture material can manifest as persistent surgical site infections that require complete removal of the underlying foreign body substrata for resolution. PMID:24833403

  20. Virtual reality robotic surgery simulation curriculum to teach robotic suturing: a randomized controlled trial.

    PubMed

    Kiely, Daniel J; Gotlieb, Walter H; Lau, Susie; Zeng, Xing; Samouelian, Vanessa; Ramanakumar, Agnihotram V; Zakrzewski, Helena; Brin, Sonya; Fraser, Shannon A; Korsieporn, Pira; Drudi, Laura; Press, Joshua Z

    2015-09-01

    The objective of this randomized, controlled trial was to assess whether voluntary participation in a proctored, proficiency-based, virtual reality robotic suturing curriculum using the da Vinci(®) Skills Simulator™ improves robotic suturing performance. Residents and attending surgeons were randomized to participation or non-participation during a 5 week training curriculum. Robotic suturing skills were evaluated before and after training using an inanimate vaginal cuff model, which participants sutured for 10 min using the da Vinci(®) Surgical System. Performances were videotaped, anonymized, and subsequently graded independently by three robotic surgeons. 27 participants were randomized. 23 of the 27 completed both the pre- and post-test, 13 in the training group and 10 in the control group. Mean training time in the intervention group was 238 ± 136 min (SD) over the 5 weeks. The primary outcome (improvement in GOALS+ score) and the secondary outcomes (improvement in GEARS, total knots, satisfactory knots, and the virtual reality suture sponge 1 task) were significantly greater in the training group than the control group in unadjusted analysis. After adjusting for lower baseline scores in the training group, improvement in the suture sponge 1 task remained significantly greater in the training group and a trend was demonstrated to greater improvement in the training group for the GOALS+ score, GEARS score, total knots, and satisfactory knots. PMID:26531197

  1. Effect of Dietary Ascorbic Acid on Osteogenesis of Expanding Midpalatal Suture in Rats

    PubMed Central

    Farhadian, Nasrin; Miresmaeili, Amirfarhang; Azar, Ramin; Zargaran, Massoumeh; Moghimbeigi, Abbas; Soheilifar, Sanaz

    2015-01-01

    Objectives: After maxillary expansion, a long period of retention is necessary to prevent early relapse. Therefore, it is beneficial to accelerate bone formation in the expanding midpalatal suture to reduce relapse. This study was designed to evaluate the effect of dietary vitamin C on osteogenesis of rat midpalatal suture during expansion. Materials and Methods: Fifty-four male Wistar rats were randomly divided into three groups, each with a control and an experimental subgroup. An open-loop spring was bonded to maxillary incisors of each animal to expand the premaxillary suture. Experimental groups received dietary vitamin C in their water. The rats in the three groups were sacrificed at three, nine or 17-day intervals after bonding the spring. Then, the premaxilla was dissected and sections were made and stained with hematoxylin and eosin and osteopontin marker. Osteoblasts and osteoclasts were counted in the suture. Two-way ANOVA and the Mann-Whitney-U test were used for analyzing the data. Results: After three days, the number of osteoblasts was significantly higher in the vitamin C group but after nine days it was significantly higher in the control group and after seventeen days there were no significant differences between the groups. Osteoclast counts were not significantly different between vitamin C and control groups. Conclusion: Vitamin C had a positive effect on osteogenesis at the beginning of bone formation in the expanding suture, but after nine days it had a negative effect on suture osteogenesis in rats. PMID:26005453

  2. Suture anchor versus screw fixation for greater tuberosity fractures of the humerus--a biomechanical study.

    PubMed

    Lin, Cheng-Li; Hong, Chih-Kai; Jou, I-Ming; Lin, Chii-Jeng; Su, Fong-Chin; Su, Wei-Ren

    2012-03-01

    Suture anchors and screws are commonly used for fixation of humeral greater tuberosity (GT) fractures in either arthroscopic or open surgeries, but no biomechanical studies have been performed to compare the strength of fixation constructs using these two implants. This cadaveric study aimed to compare the biomechanical strength of three different fixation constructs in the management of GT fractures: Double-Row Suture Anchor Fixation (DR); Suture-Bridge Technique using suture anchors and knotless suture anchors (SB); and Two-Screw Fixation (TS). The experimental procedure was designed to assess fracture displacement after cyclic loading, failure load, and failure mode of the fixation construct. Significant differences were found among the SB (321 N), DR (263 N), and TS (187 N) groups (SB > DR > TS, p < 0.05) in the mean force of cyclic loading to create 3 mm displacement. Regarding the mean force of cyclic loading to create 5 mm displacement and ultimate failure load, no significant difference was found between the DR (370 N, 480 N) and SB (399 N, 493 N) groups, but both groups achieved superior results compared with the TS group (249 N, 340 N) (p < 0.05). The results suggested that the suture anchor constructs would be stronger than the fixation construct using screws for the humeral GT fracture. PMID:21858857

  3. Identification and dynamics of a cryptic suture zone in tropical rainforest

    PubMed Central

    Moritz, C.; Hoskin, C.J.; MacKenzie, J.B.; Phillips, B.L.; Tonione, M.; Silva, N.; VanDerWal, J.; Williams, S.E.; Graham, C.H.

    2009-01-01

    Suture zones, shared regions of secondary contact between long-isolated lineages, are natural laboratories for studying divergence and speciation. For tropical rainforest, the existence of suture zones and their significance for speciation has been controversial. Using comparative phylogeographic evidence, we locate a morphologically cryptic suture zone in the Australian Wet Tropics rainforest. Fourteen out of 18 contacts involve morphologically cryptic phylogeographic lineages, with mtDNA sequence divergences ranging from 2 to 15 per cent. Contact zones are significantly clustered in a suture zone located between two major Quaternary refugia. Within this area, there is a trend for secondary contacts to occur in regions with low environmental suitability relative to both adjacent refugia and, by inference, the parental lineages. The extent and form of reproductive isolation among interacting lineages varies across species, ranging from random admixture to speciation, in one case via reinforcement. Comparative phylogeographic studies, combined with environmental analysis at a fine-scale and across varying climates, can generate new insights into suture zone formation and to diversification processes in species-rich tropical rainforests. As arenas for evolutionary experimentation, suture zones merit special attention for conservation. PMID:19203915

  4. Detection by /sup 125/I-cationized cytochrome c of proteoglycans and glycosaminoglycans immobilized on unmodified and on positively charged nylon 66

    SciTech Connect

    Heimer, R.; Molinaro, L. Jr.; Sampson, P.M.

    1987-09-01

    We have examined the detection by a /sup 125/I-labeled basic protein, cationized cytochrome c, of selected proteoglycans (PGs) and standard preparations of glycosaminoglycans (GAGs) immobilized on Nylon 66 and also on positively charged Nylon 66. Immobilization on Nylon 66 appears to allow a relative freedom of interaction between PGs or GAGs and /sup 125/I-cationized cytochrome c, but a more restricted reaction was observed when PGs and GAGs were immobilized to positively charged Nylon 66. On this support PGs with large numbers of GAG side chains reacted well with /sup 125/I-cationized cytochrome c, but GAGs were minimally reactive. By taking advantage of some of the properties of large-pore agarose-acrylamide gels, rapid partial characterization of some PGs can be accomplished in the 10-ng range, and therefore at a sensitivity equal to PGs with internal biosynthetic labels.

  5. Fusion Patterns in the Skulls of Modern Archosaurs Reveal That Sutures Are Ambiguous Maturity Indicators for the Dinosauria.

    PubMed

    Bailleul, Alida M; Scannella, John B; Horner, John R; Evans, David C

    2016-01-01

    The sutures of the skulls of vertebrates are generally open early in life and slowly close as maturity is attained. The assumption that all vertebrates follow this pattern of progressive sutural closure has been used to assess maturity in the fossil remains of non-avian dinosaurs. Here, we test this assumption in two members of the Extant Phylogenetic Bracket of the Dinosauria, the emu, Dromaius novaehollandiae and the American alligator, Alligator mississippiensis, by investigating the sequence and timing of sutural fusion in their skulls. As expected, almost all the sutures in the emu skull progressively close (i.e., they get narrower) and then obliterate during ontogeny. However, in the American alligator, only two sutures out of 36 obliterate completely and they do so during embryonic development. Surprisingly, as maturity progresses, many sutures of alligators become wider in large individuals compared to younger, smaller individuals. Histological and histomorphometric analyses on two sutures and one synchondrosis in an ontogenetic series of American alligator confirmed our morphological observations. This pattern of sutural widening might reflect feeding biomechanics and dietary changes through ontogeny. Our findings show that progressive sutural closure is not always observed in extant archosaurs, and therefore suggest that cranial sutural fusion is an ambiguous proxy for assessing maturity in non-avian dinosaurs. PMID:26862766

  6. Fusion Patterns in the Skulls of Modern Archosaurs Reveal That Sutures Are Ambiguous Maturity Indicators for the Dinosauria

    PubMed Central

    Bailleul, Alida M.; Scannella, John B.; Horner, John R.; Evans, David C.

    2016-01-01

    The sutures of the skulls of vertebrates are generally open early in life and slowly close as maturity is attained. The assumption that all vertebrates follow this pattern of progressive sutural closure has been used to assess maturity in the fossil remains of non-avian dinosaurs. Here, we test this assumption in two members of the Extant Phylogenetic Bracket of the Dinosauria, the emu, Dromaius novaehollandiae and the American alligator, Alligator mississippiensis, by investigating the sequence and timing of sutural fusion in their skulls. As expected, almost all the sutures in the emu skull progressively close (i.e., they get narrower) and then obliterate during ontogeny. However, in the American alligator, only two sutures out of 36 obliterate completely and they do so during embryonic development. Surprisingly, as maturity progresses, many sutures of alligators become wider in large individuals compared to younger, smaller individuals. Histological and histomorphometric analyses on two sutures and one synchondrosis in an ontogenetic series of American alligator confirmed our morphological observations. This pattern of sutural widening might reflect feeding biomechanics and dietary changes through ontogeny. Our findings show that progressive sutural closure is not always observed in extant archosaurs, and therefore suggest that cranial sutural fusion is an ambiguous proxy for assessing maturity in non-avian dinosaurs. PMID:26862766

  7. Performance Assessment of Suture Type, Water Temperature, and Surgeon Skill in Juvenile Chinook Salmon Surgically Implanted with Acoustic Transmitters

    SciTech Connect

    Deters, Katherine A.; Brown, Richard S.; Carter, Kathleen M.; Boyd, James W.; Eppard, M. B.; Seaburg, Adam

    2010-05-01

    This study assessed performance of seven suture types in subyearling Chinook salmon Oncorhynchus tshawytscha implanted with acoustic microtransmitters. Nonabsorbable (Ethilon) and absorbable (Monocryl) monofilament and nonabsorbable (Nurolon, silk) and absorbable (Vicryl, Vicryl Plus, Vicryl Rapide) braided sutures were used to close incisions in Chinook salmon. Monocryl exhibited greater suture retention than all other suture types 7 d after surgery. Both monofilament suture types were retained better than all braided suture types at 14 d. Incision openness and tag retention did not differ among suture types. Wound inflammation was similar for Ethilon, Monocryl, and Nurolon at 7 d. Wound ulceration was lower for Ethilon, Monocryl, and Nurolon than for all other suture types at 14 d post-surgery. Fish held in 12°C water had more desirable post-surgery healing characteristics (i.e., higher suture and tag retention and lower incision openness, wound inflammation, and ulceration) at 7 and 14 d after surgery than those held in 17°C water. The effect of surgeon was a significant predictor for all response variables at 7 d. This result emphasizes the importance of including surgeon as a variable in telemetry study analyses when multiple surgeons are used. Monocryl performed better with regard to post-surgery healing characteristics in the study fish. The overall results support the conclusion that Monocryl is the best suture material to close incisions created during surgical implantation of acoustic microtransmitters in subyearling Chinook salmon.

  8. Ultrastructure, Histochemistry, and Mineralization Patterns in the Ecdysial Suture of the Blue Crab, Callinectes sapidus

    NASA Astrophysics Data System (ADS)

    Priester, Carolina; Dillaman, Richard M.; Gay, D. Mark

    2005-12-01

    The ecdysial suture is the region of the arthropod exoskeleton that splits to allow the animal to emerge during ecdysis. We examined the morphology and composition of the intermolt and premolt suture of the blue crab using light microscopy and scanning electron microscopy. The suture could not be identified by routine histological techniques; however 3 of 22 fluorescein isothiocyanate-labeled lectins tested (Lens culinaris agglutinin, Vicia faba agglutinin, and Pisum sativum agglutinin) differentiated the suture, binding more intensely to the suture exocuticle and less intensely to the suture endocuticle. Back-scattered electron (BSE) and secondary electron observations of fracture surfaces of intermolt cuticle showed less mineralized regions in the wedge-shaped suture as did BSE analysis of premolt and intermolt resin-embedded cuticle. The prism regions of the suture exocuticle were not calcified. X-ray microanalysis of both the endocuticle and exocuticle demonstrated that the suture was less calcified than the surrounding cuticle with significantly lower magnesium and phosphorus concentrations, potentially making its mineral more soluble. The presence or absence of a glycoprotein in the organic matrix, the extent and composition of the mineral deposited, and the thickness of the cuticle all likely contribute to the suture being removed by molting fluid, thereby ensuring successful ecdysis.

  9. Efficacy of Single-Suture Incision Closures in Tagged Juvenile Chinook Salmon Exposed to Simulated Turbine Passage

    SciTech Connect

    Boyd, James W.; Deters, Katherine A.; Brown, Richard S.; Eppard, M. B.

    2011-09-01

    Reductions in the size of acoustic transmitters implanted in migrating juvenile salmonids have resulted in the use of a shorter incision-one that may warrant only a single suture for closure. However, it is not known whether a single suture will sufficiently hold the incision closed when fish are decompressed and when outward pressure is placed on the surgical site during turbine passage through hydroelectric dams. The objective of this study was to evaluate the effectiveness of single-suture incision closures on five response variables in juvenile Chinook salmon Oncorhynchus tshawytscha that were subjected to simulated turbine passage. An acoustic transmitter (0.43 g in air) and a passive integrated transponder tag (0.10 g in air) were implanted in each fish; the 6-mm incisions were closed with either one suture or two sutures. After exposure to simulated turbine passage, none of the fish exhibited expulsion of transmitters. In addition, the percentage of fish with suture tearing, incision tearing, or mortal injury did not differ between treatments. Expulsion of viscera through the incision was higher among fish that received one suture (12%) than among fish that received two sutures (1%). The higher incidence of visceral expulsion through single-suture incisions warrants concern. Consequently, for cases in which tagged juvenile salmonidsmay be exposed to turbine passage, we do not recommend the use of one suture to close 6-mm incisions associated with acoustic transmitter implantation.

  10. Electron-Beam Irradiation Effect on Thermal and Mechanical Properties of Nylon-6 Nanocomposite Fibers Infused with Diamond and Diamond Coated Carbon Nanotubes

    NASA Astrophysics Data System (ADS)

    Imam, Muhammad A.; Jeelani, Shaik; Rangari, Vijaya K.; Gome, Michelle G.; Moura, Esperidiana. A. B.

    2016-02-01

    Nylon-6 is an engineering plastic with excellent properties and processability, which are essential in several industrial applications. The addition of filler such as diamond (DN) and diamond coated carbon nanotubes (CNTs) to form molded composites may increase the range of Nylon-6 applications due to the resulting increase in strength. The effects of electron-beam irradiation on these thermoplastic nanocomposites are either increase in the cross-linking or causes chain scission. In this study, DN-coated CNTs were synthesized using the sonochemical technique in the presence of cationic surfactant cetyltrimethyl ammonium bromide (CTAB). The DN-coated CNTs nanoparticles and diamond nanoparticles were then introduced into Nylon-6 polymer through a melt extrusion process to form nanocomposite fibers. They were further tested for their mechanical (Tensile) and thermal properties (thermogravimetric analysis (TGA), differential scanning calorimetry (DSC)). These composites were further exposed to the electron-beam (160kGy, 132kGy and 99kGy) irradiation using a 1.5MeV electron-beam accelerator, at room temperature, in the presence of air and tested for their thermal and mechanical properties. The best ultimate tensile strength was found to be 690MPa and 864MPa irradiated at 132 for DN/CNTs/Nylon-6 and Diamond/Nylon-6 nanocomposite fiber as compared to 346MPa and 321MPa for DN/CNTs/Nylon-6 and Diamond/Nylon-6 nanocomposite fiber without irradiation. The neat Nylon-6 tensile strength was 240MPa. These results are consistent with the activation energy calculated from TGA graphs. DSC analysis result shows that the slight increase in glass transition temperature (Tg) and decrease in melting temperature (Tm) which was expected from high electron-beam radiation dose.

  11. Degradation of Nylon 6,6 Fire-Suppression Casing from Plutonium Glove Boxes Under Alpha and Neutron Irradiation

    DOE PAGESBeta

    Millsap, Donald W.; Cournoyer, Michael E.; Landsberger, Sheldon; Tesmer, Joseph R.; Wang, Matthew Y.

    2015-04-23

    Nylon 6,6 tensile specimens, conforming to the casing for self-contained fire extinguisher systems, have been irradiated using both an accelerator He++ ion beam and a 5-Ci PuBe neutron source to model the radiation damage these systems would likely incur over a lifetime of operation within glove boxes. Following irradiation, these samples were mechanically tested using standard practices as described in ASTM D638. The results of the He++ study indicate that the tensile strength of the nylon specimens undergoes some slight (<10%) degradation while other properties of the samples, such as elongation and tangent modulus, appear to fluctuate with increasing dosemore » levels. The He++-irradiated specimens also have a noticeable level of discoloration corresponding to increasing levels of dose. The neutron-irradiated samples show a higher degree of mechanical degradation than the He++-irradiated samples.« less

  12. Degradation of Nylon 6,6 Fire-Suppression Casing from Plutonium Glove Boxes Under Alpha and Neutron Irradiation

    SciTech Connect

    Millsap, Donald W.; Cournoyer, Michael E.; Landsberger, Sheldon; Tesmer, Joseph R.; Wang, Matthew Y.

    2015-04-23

    Nylon 6,6 tensile specimens, conforming to the casing for self-contained fire extinguisher systems, have been irradiated using both an accelerator He++ ion beam and a 5-Ci PuBe neutron source to model the radiation damage these systems would likely incur over a lifetime of operation within glove boxes. Following irradiation, these samples were mechanically tested using standard practices as described in ASTM D638. The results of the He++ study indicate that the tensile strength of the nylon specimens undergoes some slight (<10%) degradation while other properties of the samples, such as elongation and tangent modulus, appear to fluctuate with increasing dose levels. The He++-irradiated specimens also have a noticeable level of discoloration corresponding to increasing levels of dose. The neutron-irradiated samples show a higher degree of mechanical degradation than the He++-irradiated samples.

  13. A carbon nanotubes photoconductive detector for middle and far infrared regions based on porous silicon and a polyamide nylon polymer

    NASA Astrophysics Data System (ADS)

    Saleh, Wasan R.

    2015-06-01

    Sensitive and good response photoconductive detectors working in the middle and far infrared regions were fabricated. These detectors were fabricated based on multi and double walled carbon nanotube films and works at room temperature. The films were deposited on a porous silicon (PSi) nanosurface. The surfaces were functionalized by a thin layer of polyamide nylon polymer to improve the photoresponsivity of the fabricated detectors. The response time of the fabricated MWCNTs-PSi detectors were 30 and 0.22 ms for the middle and far IR region respectively. The functionalisation of the MWCNTs-PSi film surface by the polyamide nylon polymer improved the photoconductive gain, photoresponsivity, and specific conductivity in both MWCNTs-PSi and DWCNTs-PSi detectors. The designed carbon nanotube (CNT) based photodetector has low cost, high sensitivity and reasonable speed for the middle and far IR spectral range without cooling.

  14. Low background techniques and experimental challenges for Borexino and its nylon vessels

    NASA Astrophysics Data System (ADS)

    Pocar, Andrea Pietro

    Borexino is an experiment for low energy (<1 MeV) solar neutrino spectroscopy approaching completion at the underground Gran Sasso laboratories in Italy. It is specifically designed to measure in real time the flux of mono-energetic {berillium} neutrinos produced by fusion reactions in the Sun. Its 300-ton liquid scintillator target is contained in an 8.5 meter diameter nylon inner vessel (IV) and is surrounded by 1000 tons of buffer fluid. A second, 11.5 meter diameter concentric nylon outer vessel (OV) around the IV serves as a barrier for radon emanated at the periphery of the detector. Borexino requires unprecedented low levels of radioactive impurities to be a success (˜1 background event/day in the central 100-tons of scintillator). The IV, which is in direct contact with the scintillator, also has to meet extremely stringent radioactive and cleanliness requirements. Intrinsic levels ˜10 -12 g/g for U and Th and ˜10-8 g/g for K are needed. The vessels, assembled in a clean room in Princeton, made of a 125 micron-thick membrane, need to be leak tight at the 10-2 cc/s and 1 cc/s level for the IV and OV respectively, and have to withstand mechanical stresses due to density differences and temperature gradients between the fluids they contain. Their requirements and assembly process are presented in detail. An upper limit on the inner vessel leak rate of 10-3 cc/s was measured. The performance of a matrix of light sources, placed on both vessels for monitoring its shape with digital cameras, is demonstrated. The problem of surface contamination by radon in the air is extensively addressed, strategies for minimizing it are analysed and the effectiveness of their application evaluated. In particular, an original radon filter based on vacuum swing adsorption on activated charcoal has been developed for use in connection with the clean room. Such a technique yielded radon abatement factors in excess of 104 in a small-scale prototype, and ˜100 in the final system

  15. Precise study of nonlinear optical coefficients and hyperpolarizabilities in cold-drawn and poled ferroelectric Nylon 11 films

    NASA Astrophysics Data System (ADS)

    Tsutsumi, Naoto; Mizutani, Toru; Sakai, Wataru; Watanabe, Toshiyuki; Miyata, Seizo

    1998-06-01

    This paper presents a precise study of second-order optical nonlinearity of uniaxially cold-drawn and poled ferroelectric Nylon 11 films. The effects of drawing and poling on refractive indices and second-order nonlinear optical coefficients have been investigated. Drawing caused increase of refractive index (n) parallel to the drawing direction nX, and decrease of n perpendicular to drawing direction in the plane of film nY, as well as decrease of n on the poling direction parallel to film thickness direction nZ. Poling caused significant increase of nZ and decrease of nY. These n results imply that poling aligns the molecular chains so that carbonyl groups in Nylon backbone orient in the poling direction (Z-axis). Cold-drawn and poled Nylon 11 films belong to the mm2 point group. Dependence of second-order harmonic generation (SHG) intensity on incidence angle, i.e., Maker fringe pattern, could be precisely fitted using five independent nonzero tensor components, d33, d32, d31, d15, and d24. However, Kleinman symmetry was not satisfied: d31≠d15 and d32≠d24. The tensor components d33, d31, d15, and d24 increase with increasing remanent polarization, whereas the value of d32 was negligibly small irrespective of the intensity of the remanent polarization. Tensor components of microscopic first-order hyperpolarizability, βzxx, βzyy, βzzz, βxxz, and βyyz were determined. Tensor component βzzz was the largest and βzxx had negative sign. Second-order nonlinearity was largely suppressed in the vicinity of the melting point of Nylon 11.

  16. Comparison of Reactive Mercury Concentrations Measured Simultaneously Using KCl-coated Denuders, Nylon Membranes, and Cation Exchange Membranes

    NASA Astrophysics Data System (ADS)

    Gustin, M. S.; Huang, J.; Miller, M. B.; Weiss-Penzias, P. S.

    2012-12-01

    There is much debate about the chemistry of reactive gaseous and particle bound mercury (Hg) in the atmosphere, and the processes associated with formation. In addition, there are concerns regarding the interferences and calibration of the widely used Tekran® 2537/1130/1135 Hg measurement system. To investigate these we developed simple laboratory and field sampling systems designed to collect and analyze reactive Hg (Hg (II), Hg (I) and/or particle bound). A manifold system was applied in the laboratory, and in the field, in-series and -parallel membranes, flow controllers and pumps were utilized. Both systems actively collected reactive Hg using nylon membranes and cation exchange membranes alongside measurements made using the Tekran® system. The analytical system consisted of step wise 2.5 minute thermo-desorption and Hg quantification by cold vapor atomic fluorescence. In the laboratory, we compared the efficiency of these surfaces for collection of HgO, HgCl2, and HgBr2 when permeated into Hg and oxidant free air, and ambient filtered air. Other tests are ongoing. Thus far, results show concentrations measured by the cation exchange membrane were two-to-three fold greater than that measured by the nylon membranes, and three-to -four fold greater than that measured by the KCl-coated annual denuder. Thermo-desorption profiles obtained using nylon membranes show slightly different patterns associated with the reactive Hg compounds as permeated and tested. Field measurements were made at two locations in Reno, Nevada (a high traffic site and an agricultural area) and at Elkhorn Slough, California (marine site). Desorption profiles from nylon membrane differed by site and by time of year. Although the influence of aerosol on this measurement has not been explored, field results suggest different forms of reactive Hg were present in the atmosphere as a function of season and location.

  17. Deep suture zone in the North Barents Basin

    NASA Astrophysics Data System (ADS)

    Butsenko, Viktor; Kireev, Artem; Piskarev, Alexey; Savin, Vasily; Smirnov, Oleg

    2015-04-01

    Study of sedimentary basin evolution is a part of research for the forecast of oil and gas capacity of the North Barents shelf. Maps of potential fields anomalies are compiled on the basis of the latest geophysical databases, structural maps of the seismic horizons are analyzed, the location of sources of potential fields anomalies are calculated, 3D density and magnetic models of Earth's crust are constructed. Six seismic complexes are allocated in sedimentary cover structure: Devonian - Lower Carboniferous, Upper Carboniferous - Lower Permian, Mid Permian - Lower Triassic, Triassic - Lower Jurassic, Upper Jurassic - Lower Cretaceous, Lower Cretaceous - Quaternary. The research of lateral changes of allocated layers thickness gives an idea of sedimentation in the region on various time intervals. The structural and tectonic scheme of the region is made after analysis of new geologic-geophysical materials. Contact zones of heterogeneous blocks of the crystalline basement are marked, disjunctive dislocations in a sedimentary cover and the upper crust, and also zones of increase of sediments thickness in various seismic complexes are designated. The deep suture zone delimiting Mesozoic and Paleozoic sedimentary basins has the most important geological value among disjunctive zones of the region. This zone stretches along the Admiralty Arch in East part of the North Barents shelf and is marked by negative magnetic anomaly 30-50 km wide. In view of special tectonic value of the suture zone marked by this anomaly we have calculated the 3D magnetic crust model. The sedimentary layers of a model section is based on seismic data. As a result of modeling the studied anomaly of a magnetic field can be approximated by the block of basement rocks of the lowered magnetization (1.2 A/m). The surface of this block is located in a zone of anomaly at a depth of 12-14 km. The asymmetry of anomaly is accounted by an inclination to East of the borders of the block with low

  18. Investigation Of Dielectric Behaviors Of Nanoclay Filled Epoxy And PP/NYLON66 Nanocomposites For Cable Insulation Application

    NASA Astrophysics Data System (ADS)

    Rashmi, Renukappa, N. M.; Siddaramaiah

    2010-10-01

    High performance polymer nanocomposites are emerging as a new class of materials for its demanding applications as insulating material. The outstanding properties of nanoclay make them an attractive candidate for preparing advanced composite materials with multi functional features for electrical and electronics applications. A series of nanoclay incorporated epoxy and polypropylene/nylon66 (50/50 blend) nanocomposites have been prepared via chemical and melt mixing methods respectively. The fabricated nanocomposites have been characterized for dielectric behaviors such as dielectric constant (ɛ r ) and dissipation factor (tan δ). The effect of filler content, frequency, temperature and sea water ageing on dielectric behavior of nanocomposites has been investigated. The variation in the diffusion coefficient (D) of the material aged in water at different temperature with different percentage of nanoclay loaded epoxy and PP/nylon66 nanocomposites were calculated. It is observed that at increase in ageing temperature relatively increases the diffusion coefficient of the material. The measured dielectric results of the nanocomposites reveals that a significant influence of frequency and sea water ageing and marginal change with temperature. Higher dielectric constant was noticed for epoxy nanocomposites as compared to PP/nylon66 composites

  19. Uncertainties of Gaseous Oxidized Mercury Measurements Using KCl-Coated Denuders, Cation-Exchange Membranes, and Nylon Membranes: Humidity Influences.

    PubMed

    Huang, Jiaoyan; Gustin, Mae Sexauer

    2015-05-19

    Quantifying the concentration of gaseous oxidized mercury (GOM) and identifying the chemical compounds in the atmosphere are important for developing accurate local, regional, and global biogeochemical cycles. The major hypothesis driving this work was that relative humidity affects collection of GOM on KCl-coated denuders and nylon membranes, both currently being applied to measure GOM. Using a laboratory manifold system and ambient air, GOM capture efficiency on 3 different collection surfaces, including KCl-coated denuders, nylon membranes, and cation-exchange membranes, was investigated at relative humidity ranging from 25 to 75%. Recovery of permeated HgBr2 on KCl-coated denuders declined by 4-60% during spikes of relative humidity (25 to 75%). When spikes were turned off GOM recoveries returned to 60 ± 19% of permeated levels. In some cases, KCl-coated denuders were gradually passivated over time after additional humidity was applied. In this study, GOM recovery on nylon membranes decreased with high humidity and ozone concentrations. However, additional humidity enhanced GOM recovery on cation-exchange membranes. In addition, reduction and oxidation of elemental mercury during experiments was observed. The findings in this study can help to explain field observations in previous studies. PMID:25877790

  20. Electrospun nylon-6 spider-net like nanofiber mat containing TiO(2) nanoparticles: a multifunctional nanocomposite textile material.

    PubMed

    Pant, Hem Raj; Bajgai, Madhab Prasad; Nam, Ki Taek; Seo, Yun A; Pandeya, Dipendra Raj; Hong, Seong Tshool; Kim, Hak Yong

    2011-01-15

    In this study, electrospun nylon-6 spider-net like nanofiber mats containing TiO(2) nanoparticles (TiO(2) NPs) were successfully prepared. The nanofiber mats containing TiO(2) NPs were characterized by SEM, FE-SEM, TEM, XRD, TGA and EDX analyses. The results revealed that fibers in two distinct sizes (nano and subnano scale) were obtained with the addition of a small amount of TiO(2) NPs. In low TiO(2) content nanocomposite mats, these nanofiber weaves were found uniformly loaded with TiO(2) NPs on their wall. The presence of a small amount of TiO(2) NPs in nylon-6 solution was found to improve the hydrophilicity (antifouling effect), mechanical strength, antimicrobial and UV protecting ability of electrospun mats. The resultant nylon-6/TiO(2) antimicrobial spider-net like composite mat with antifouling effect may be a potential candidate for future water filter applications, and its improved mechanical strength and UV blocking ability will also make it a potential candidate for protective clothing. PMID:20875702

  1. A pilot study evaluating laparoscopic closure of the nephrosplenic space using an endoscopic suturing device in standing horses.

    PubMed

    Bracamonte, José L; Duke-Novakovski, Tanya

    2016-06-01

    This study evaluated the use of an articulating automated suturing device for laparoscopic closure of the nephrosplenic space in standing horses. Closure of the nephrosplenic space was performed in 4 horses using an automated suturing device. Second-look laparoscopy was performed at 5 weeks. A smooth fibrous adhesion formed between the spleen, the perirenal fascia, and the nephrosplenic ligament in 3 of the 4 horses in which the nephrosplenic space was closed using the automated suturing device. In 1 horse, closure of the nephrosplenic space was not possible due to constant breakage of the endoscopic needle. Intra-operative complications encountered with the automated suturing device were tearing of the perirenal fascia, nephrosplenic ligament, and dorsal splenic capsule along with breakage of the needle. The automated suturing device used in this study for laparoscopic closure of the nephrosplenic space resulted in longer surgery times, suffered instrument failures and delivered inadequate suture. PMID:27247467

  2. The B-Lynch uterine brace suture, and a bit of this and a bit of that...

    PubMed

    Karoshi, Mahantesh

    2010-03-01

    The widespread application of the B-Lynch brace suture to control postpartum hemorrhage has sparked interest in a variety of adjunctive methods, used alone or in combination, to control uterine bleeding. Although the B-Lynch brace suture has been used with good results throughout the world, failures can and do occur in rare instances, especially when the suture is incorrectly placed for use for an inappropriate indication. Four reports of additional methods to control postpartum hemorrhage are published in this issue of IJGO. Three use the B-Lynch brace suture combined with other techniques. The need for additional techniques reminds the reader of the importance of proper suture application for proper indication. Potential reasons for failure of the B-Lynch suture are provided. PMID:20070962

  3. Neutron Spectroscopy of the Alpha and Gamma Forms of Nylon-6 Polymer

    NASA Astrophysics Data System (ADS)

    Papanek, Peter; Fischer, John E.; Murthy, N. S.

    1998-03-01

    The polyamide nylon-6 crystallizes in two different forms, α and γ, characterized by different chain conformations, and different arrangement of hydrogen bonds between chains. We have performed inelastic neutron scattering experiments to study the effects of H-bonding on lattice dynamics in both forms. Selectively deuterated and stretch oriented samples were used in order to identify the phonon modes and determine their polarization with respect to chain axes. Two complementary techniques, the filter-analyzer and time-of-flight (TOF) spectroscopy were employed. We have found that certain modes are similar in both α and γ fibers, however there are also significant differences in the 12--40 meV range, and in the frequencies of amide VI and amide VII modes. TOF spectra of both forms show broad low-frequency Boson peaks also at slightly different positions. The experimental results will be compared with semiempirical and ab initio calculations for a pair of chains at different relative orientations, and the relationship between the strength of H-bonds and amide vibrations will be discussed.

  4. Nylon 6,6 electrospun fibres reinforced by amino functionalised 1D and 2D carbon

    NASA Astrophysics Data System (ADS)

    Navarro-Pardo, F.; Martínez-Barrera, G.; Martínez-Hernández, A. L.; Castaño, V. M.; Rivera-Armenta, J. L.; Medellín-Rodríguez, F.; Velasco-Santos, C.

    2012-09-01

    Nylon 6,6 electrospun nanocomposites were prepared and reinforced with 0.1, 0.5 and 1wt.% of 1D and 2D carbon. Both carbon nanotubes and graphene were functionalised with amino groups (f-CNT and f-Ge respectively). The morphology and graphitization changes of carbon nanomaterials were evaluated by transmission electron microscopy (TEM) and Raman spectroscopy; functional groups of modified nanomaterials was analysed by infrared spectroscopy. The mechanical response and the crystallinity of the fibres were measured by dynamical mechanical analysis, differential scanning calorimetry and wide angle x-ray diffraction. The morphology and dispersion of the nanomaterials in the nanofibres was studied by scanning electron microscopy and TEM. The storage modulus was improved by 118% for f-CNT and 116% for f-Ge. The mechanical response of the nanocomposites exhibited different behaviour upon loading of 1D and 2D carbon. This trend is consistent with the crystallinity of the nanofibres. This study showed f-CNT resulted in better mechanical properties at the lowest loading. On the other hand f-Ge showed improved reinforcing effect by increasing the filler loading. The two-dimensional structure of graphene was an important factor for the higher crystallinity in the electrospun nanofibres.

  5. Oligosaccharide mapping of heparan sulphate by polyacrylamide-gradient-gel electrophoresis and electrotransfer to nylon membrane.

    PubMed Central

    Turnbull, J E; Gallagher, J T

    1988-01-01

    A new method that we have called 'oligosaccharide mapping' is described for the analysis of radiolabelled heparan sulphate and other glycosaminoglycans. The method involves specific enzymic or chemical scission of polysaccharide chains followed by high-resolution separation of the degradation products by polyacrylamide-gradient-gel electrophoresis. The separated oligosaccharides are immobilized on charged nylon membranes by electrotransfer and detected by fluorography. A complex pattern of discrete bands is observed covering an oligosaccharide size range from degree of polymerization (d.p.) 2 (disaccharide) to approximately d.p. 40. Separation is due principally to differences in Mr, though the method also seems to detect variations in conformation of oligosaccharide isomers. Resolution of oligosaccharides is superior to that obtained with isocratic polyacrylamide-gel-electrophoresis systems or gel chromatography, and reveals structural details that are not accessible by other methods. For example, in this paper we demonstrate a distinctive repeating doublet pattern of iduronate-rich oligosaccharides in heparitinase digests of mouse fibroblast heparan sulphate. This pattern may be a general feature of mammalian heparan sulphates. Oligosaccharide mapping should be a valuable method for the analysis of fine structure and sequence of heparan sulphate and other complex polysaccharides, and for making rapid assessments of the molecular distinctions between heparan sulphates from different sources. Images Fig. 2. Fig. 3. Fig. 4. Fig. 5. Fig. 6. Fig. 7. Fig. 8. PMID:2969727

  6. Analysis of Dyes Extracted from Millimeter-Size Nylon Fibers by Micellar Electrokinetic Chromatography

    SciTech Connect

    Lewis, L.A.

    2001-07-30

    The Learning Objective is to present to the forensic community a potential qualitative/quantitative method for trace-fiber color comparisons using micellar electrokinetic chromatography (MEKC). Developing a means of analyzing extracted dye constituents from millimeter-size nylon fiber samples was the objective of this research initiative. Aside from ascertaining fiber type, color evaluation and source comparison of trace-fiber evidence plays a critical role in forensic-fiber examinations. Literally thousands of dyes exist to date, including both natural and synthetic compounds. Typically a three-color-dye combination is employed to affect a given color on fiber material. The result of this practice leads to a significant number of potential dye combinations capable of producing a similar color and shade. Since a typical forensic fiber sample is 2 mm or less in length, an ideal forensic dye analysis would qualitatively and quantitatively identify the extracted dye constituents from a sample size of 1 mm or smaller. The goal of this research was to develop an analytical method for comparing individual dye constituents from trace-fiber evidence with dyes extracted from a suspected source, while preserving as much of the original evidence as possible.

  7. Experimental characterization of thermally-activated artificial muscles based on coiled nylon fishing lines

    NASA Astrophysics Data System (ADS)

    Cherubini, Antonello; Moretti, Giacomo; Vertechy, Rocco; Fontana, Marco

    2015-06-01

    The discovery of an innovative class of thermally activated actuators based on twisted polymeric fibres has opened new horizons toward the development of effective devices that can be easily manufactured using inexpensive materials such as fishing lines or sewing threads. These new devices show large deformations when heated together with promising performance in terms of energy and power densities. With the aim of providing information and data useful for the future engineering applications, we present the results of a thermo-mechanical characterization conducted on a specific type of twisted polymeric fibre (i.e. nylon-made coiled actuators) that is considered particularly promising. A custom experimental test-bench and procedure have been developed and employed to run isothermal and isometric tensile tests on a set of specimens that are fabricated with a simple and repeatable process. The results of the experiments highlight some important issues related to the response of these actuators such as hysteresis, repeatability, predictability and stored elastic energy.

  8. Medium Effects on Minimum Inhibitory Concentrations of Nylon-3 Polymers against E. coli

    PubMed Central

    Choi, Heejun; Chakraborty, Saswata; Liu, Runhui; Gellman, Samuel H.; Weisshaar, James C.

    2014-01-01

    Minimum inhibitory concentrations (MICs) against E. coli were measured for three nylon-3 polymers using Luria-Bertani broth (LB), brain-heart infusion broth (BHI), and a chemically defined complete medium (EZRDM). The polymers differ in the ratio of hydrophobic to cationic subunits. The cationic homopolymer is inert against E. coli in BHI and LB, but becomes highly potent in EZRDM. A mixed hydrophobic/cationic polymer with a hydrophobic t-butylbenzoyl group at its N-terminus is effective in BHI, but becomes more effective in EZRDM. Supplementation of EZRDM with the tryptic digest of casein (often found in LB) recapitulates the LB and BHI behavior. Additional evidence suggests that polyanionic peptides present in LB and BHI may form electrostatic complexes with cationic polymers, decreasing activity by diminishing binding to the anionic lipopolysaccharide layer of E. coli. In contrast, two natural antimicrobial peptides show no medium effects. Thus, the use of a chemically defined medium helps to reveal factors that influence antimicrobial potency of cationic polymers and functional differences between these polymers and evolved antimicrobial peptides. PMID:25153714

  9. Knotless single-row rotator cuff repair: a comparative biomechanical study of 2 knotless suture anchors.

    PubMed

    Efird, Chad; Traub, Shaun; Baldini, Todd; Rioux-Forker, Dana; Spalazzi, Jeffrey P; Davisson, Twana; Hawkins, Monica; McCarty, Eric

    2013-08-01

    The purpose of this study was to compare the gap formation during cyclic loading, maximum repair strength, and failure mode of single-row full-thickness supraspinatus repairs performed using 2 knotless suture anchors with differing internal suture-retention mechanisms in a human cadaver model. Nine matched pairs of cadaver shoulders were used. Full-thickness tears were induced by detaching the supraspinatus tendon from the greater tuberosity. Single-row repairs were performed with either type I (Opus Magnum PI; ArthroCare, Austin, Texas) or type II (ReelX STT; Stryker, Mahwah, New Jersey) knotless suture anchors. The repaired tendon was cycled from 10 to 90 N for 500 cycles, followed by load to failure. Gap formation was measured at 5, 100, 200, 300, 400, and 500 cycles with a video digitizing system. Anchor type or location (anterior or posterior) had no effect on gap formation during cyclic loading regardless of position (anterior, P=.385; posterior, P=.389). Maximum load to failure was significantly greater (P=.018) for repairs performed with type II anchors (288±62 N) compared with type I anchors (179±39 N). Primary failure modes were anchor pullout and tendon tearing for type II anchors and suture slippage through the anchor for type I anchors. The internal ratcheting suture-retention mechanism of type II anchors may have helped this anchor outperform the suture-cinching mechanism of type I anchors by supporting significantly higher loads before failure and minimizing suture slippage, potentially leading to stronger repairs clinically. PMID:23937749

  10. Suture Line Response of End-to-Side Anastomosis: A Stress Concentration Methodology.

    PubMed

    Roussis, P C; Giannakopoulos, A E; Charalambous, H P

    2015-03-01

    End-to-side vascular anastomosis has a considerable complexity regarding the suturing of the juncture line between the artery and the graft. The present study proposes a stress-concentration methodology for the prediction of the stress distribution at the juncture line, aiming to provide generic expressions describing the response of an end-to-side anastomosis. The proposed methodology is based on general results obtained from the analysis of pipe connections, a topic that has been investigated in recent years in the field of offshore structural engineering. A key aspect for implementing the stress-concentration-factor approach is the recognition that the axial load due to pressure and flow dynamics exerted along the graft axis controls the "hot spots" on the juncture line, which in turn affects the mechanical response of the sutures. Several parameters, identified to influence the suture line response, are introduced in closed-form expressions for the suture line response calculations. The obtained results compare favorably with finite element results published in the literature. The proposed model predicts analytically the suture line response of end-to-side anastomosis, while capturing the influence of and interdependence among the problem parameters. Lower values of the graft radius, the distance between sequential stitches, and the intersecting angle between the artery and the graft are some of the key parameters that reduce the suture line response. The findings of this study are broad in scope and potentially applicable to improving the end-to-side anastomosis technique through improved functionality of the sutures and optimal selection of materials and anastomosis angle. PMID:26577101

  11. Internal morphology of the nonsyndromic prematurely fused sagittal suture in the human skull--A preliminary micro-CT study.

    PubMed

    Nowaczewska, W; Ziółkowski, G; Dybała, B

    2015-10-01

    Although nonsyndromic craniosynostosis (NSC) of the sagittal suture is a well-known type of craniosynostosis, little is currently known about the internal morphology of this prematurely fused suture in modern humans. Recently, micro-computed tomography (micro-CT) has been applied as a new tool for the quantitative evaluation of cranial suture morphology. However, so far there are only a small number of reports concerning studies of the internal morphology of prematurely fused sagittal suture in humans using micro-CT. The primary aim of this study was to examine the internal morphology of a completely obliterated sagittal suture in NSC. Two modern human skulls were used in this study: a skull of a child (aged 10 ± 2.5 years) displaying NSC of the sagittal suture and a skull of an adult showing non-prematurely completely obliterated sagittal suture. Quantitative variables of the sagittal sutures were assessed using method proposed by the authors. Porosity, and relative thickness of three bone layers in two examined skulls (inner cortical, diploë and outer cortical) were analysed using micro-CT in three equal sections of the sagittal suture. In the case of the prematurely fused suture, there were statistically significant differences mainly in the mean values of the porosity, thickness and relative thickness of the diploë between the anterior part and the two other parts (central and posterior) of this suture. Significant differences were also observed in some of the analysed variables between the sections of the sagittal suture of the skull with NSC and the normal skull. PMID:26122169

  12. Antibacterial suture vs silk for the surgical removal of impacted lower third molars. A randomized clinical study

    PubMed Central

    Sala-Pérez, Sergi; López-Ramírez, Marta; Quinteros-Borgarello, Milva; Valmaseda-Castellón, Eduardo

    2016-01-01

    Background The aim of this study was to evaluate the clinical and microbiological impact of an antibacterial suture (Monocryl® Plus) in the surgical removal of I3M. Material and Methods A “split-mouth”, prospective pilot clinical study was designed involving 20 patients programmed for the surgical removal of I3M. Each side was randomly sutured with Monocryl® Plus or silk suture and removed for microbiological study 72 hours and 7 days after surgery. Presence of SSI, wound bleeding and the degree of discomfort associated with each type of suture material (scored by means of a visual analog scale) were evaluated. The level of contamination of each material was observed under the scanning electron microscope. Results Wound bleeding upon suture removing was slightly greater after 72 hours and 7 days with black silk suture, though the differences were not statistically significant (p=0.752 and p=0.113, respectively). Patient discomfort was very similar with both types of suture material (p=0.861). Only one case of SSI was recorded with black silk suture after 72 hours. Microbiologically, the antibacterial suture showed a lesser presence of microorganisms (p<0.001, at 72h and p=0.033 at 7th day, respectively). The most common bacterial species included grampositive cocci (Streptococcus viridans group, Neisseria spp., Coagulasenegative Staphylococcus and Peptostreptococcus), gramnegative cocci (Veillonella), grampositive Bacilli (Lactobacillus), and gramnegative Bacilli (Prevotella). Conclusions The greatest antibacterial effect of Monocryl Plus suture was observed after 72 hours. According to most authors, there is no doubt that this antibacterial suture can provide little safety in the control of SSI. Key words:Antibacterial suture, monocryl® plus, vicryl® plus, third molar surgery, postoperative infection, surgical site infection (SSI). PMID:26615503

  13. Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears

    PubMed Central

    Milchteim, Charles; Branch, Eric A.; Maughon, Ty; Hughey, Jay; Anz, Adam W.

    2016-01-01

    Background: Longitudinal meniscus tears are commonly encountered in clinical practice. Meniscus repair devices have been previously tested and presented; however, prior studies have not evaluated repair construct designs head to head. This study compared a new-generation meniscus repair device, SpeedCinch, with a similar established device, Fast-Fix 360, and a parallel repair construct to a crossed construct. Both devices utilize self-adjusting No. 2-0 ultra–high molecular weight polyethylene (UHMWPE) and 2 polyether ether ketone (PEEK) anchors. Hypothesis: Crossed suture repair constructs have higher failure loads and stiffness compared with simple parallel constructs. The newer repair device would exhibit similar performance to an established device. Study Design: Controlled laboratory study. Methods: Sutures were placed in an open fashion into the body and posterior horn regions of the medial and lateral menisci in 16 cadaveric knees. Evaluation of 2 repair devices and 2 repair constructs created 4 groups: 2 parallel vertical sutures created with the Fast-Fix 360 (2PFF), 2 crossed vertical sutures created with the Fast-Fix 360 (2XFF), 2 parallel vertical sutures created with the SpeedCinch (2PSC), and 2 crossed vertical sutures created with the SpeedCinch (2XSC). After open placement of the repair construct, each meniscus was explanted and tested to failure on a uniaxial material testing machine. All data were checked for normality of distribution, and 1-way analysis of variance by ranks was chosen to evaluate for statistical significance of maximum failure load and stiffness between groups. Statistical significance was defined as P < .05. Results: The mean maximum failure loads ± 95% CI (range) were 89.6 ± 16.3 N (125.7-47.8 N) (2PFF), 72.1 ± 11.7 N (103.4-47.6 N) (2XFF), 71.9 ± 15.5 N (109.4-41.3 N) (2PSC), and 79.5 ± 25.4 N (119.1-30.9 N) (2XSC). Interconstruct comparison revealed no statistical difference between all 4 constructs regarding maximum

  14. Internal calvarial bone distraction in rabbits with delayed-onset coronal suture synostosis.

    PubMed

    Losken, H W; Mooney, M P; Zoldos, J; Tschakaloff, A; Burrows, A M; Smith, T D; Cooper, G M; Kapucu, M R; Siegel, M I

    1998-09-01

    Recent studies have identified a subpopulation of craniosynostotic individuals who exhibit progressive or delayed-onset synostosis and mild craniofacial growth abnormalities. These individuals may be good candidates for nonextirpation, distraction osteogenesis therapy. The present study was designed to test this hypothesis by using internal calvarial bone distraction in a rabbit model with familial delayed-onset craniosynostosis. Data were collected from 159 rabbits: 71 normal controls, 72 with delayed-onset coronal suture synostosis, 8 with delayed-onset coronal suture synostosis and coronal suturectomy, and 8 with delayed-onset coronal suture synostosis and distraction. At 10 days of age, all rabbits had amalgam markers placed on both sides of the frontonasal, coronal, and anterior lambdoidal sutures. At 25 days of age, correction was accomplished through either a 5-mm-wide suturectomy or distraction osteogenesis. An internal distraction appliance was fixed to the frontal and parietal bones and percutaneously and intermittently activated at an average of 0.10 mm/day for 42 days (4.11 mm total). Serial radiographs were taken at 10, 25, 42, and 84 days of age. Results revealed that rabbits with delayed-onset synostosis had significantly (p < 0.01) reduced coronal suture growth rates (0.04 mm/day) compared with the other three groups (0.07 mm/day). Rabbits with suturectomy and rabbits with distraction showed similar coronal suture responses. However, from 42 to 84 days of age, rabbits with distraction showed reduced growth at the vault sutures and abnormal growth patterns in cranial vault width, cranial vault shape, and cranial base angulation compared with the other three groups. Results demonstrated that, although the normal coronal suture growth rate was maintained in rabbits with delayed-onset synostosis using intermittent distraction osteogenesis, normal adult craniofacial structure was not achieved. Such anomalous growth was probably a result of altered growth

  15. [In vitro studies of the mechanical load capability of resorbable monofilament suture materials].

    PubMed

    Bremer, Felicia; Gellrich, Nils-Claudius; Stiesch, Meike

    2009-01-01

    In a vast spectrum of wound closures there is an indication for resorbable suture materials. For surgeons detailed knowledge of the physicochemical properties is important in order to find the right suture for each indication. For this purpose, various new monofilament polymers were employed. The objective of the present study was to investigate the effects of hydrolysis and gamma-irradiation on the linear strength. The final analysis of all tested suture materials concluded that gamma-irradiation had no effects on linear strength. However, the analysis showed significant discrepancies between individual polymers with regard to loss of tensile strength associated with hydrolysis. Polydioxanone- and caprolactone-lactid-based resorbable suture materials both displayed adequate tensile strength after a five-week period of hydrolysis. In comparison the triblock-copolymer is subject to rapid degradation. Polydioxanone- and caprolactone-lactid-based resorbable suture materials are indicated for use in tissues which require mechanical support over a longer period. Monosyn is more suitable for short-term wound support. PMID:19852206

  16. The Optimal Placement of Sutures in All-inside Repair of Meniscocapsular Separation

    PubMed Central

    Tiftikci, Uğur; Serbest, Sancar

    2016-01-01

    Background: The aim of this study was to show the effects on the meniscus of repair applied from the femoral, the femoral-tibial and the tibial surfaces. Methods: In the treatment of meniscocapsular separation, although the accepted gold standard technique in the past was the inside-out suture technique, the current treatment method is all-inside repair methods. The all-inside techniques include the hook method and applications with a meniscus suture device. The hook method is difficult with a steep learning curve. In meniscus repair applied with the all-inside meniscus devices, the application of the suture can change the anatomic structure and position of the meniscus. Results: The suturing method applied from the tibial section of the meniscus does not disrupt the anatomic position of the meniscus in meniscocapsular separation. Thus, the optimum conditions are provided for restoration of the functions of the meniscus. Conclusion: The optimal repair in meniscocapsular separations can be considered to be that made with sutures from the tibial section of the meniscus. This technique may be helpful in obtaining better clinical results. PMID:27347236

  17. LED phototherapy on midpalatal suture after rapid maxilla expansion: a Raman spectroscopic study

    NASA Astrophysics Data System (ADS)

    Rosa, Cristiane B.; Habib, Fernando Antonio L.; de Araújo, Telma M.; dos Santos, Jean N.; Cangussu, Maria Cristina T.; Barbosa, Artur Felipe S.; de Castro, Isabele Cardoso V.; Soares, Luiz Guilherme P.; Pinheiro, Antonio L. B.

    2015-03-01

    A quick bone formation after maxillary expansion would reduce treatment timeand the biomodulating effects of LED light could contribute for it. The aim of this study was to analyze the effect of LED phototherapy on the acceleration of bone formation at the midpalatal suture after maxilla expansion. Thirty rats divided into 6 groups were used on the study at 2 time points - 7 days: Control; Expansion; and Expansion + LED; and 14 days: Expansion; Expansion + LED in the first week; Expansion and LED in the first and second weeks. LED irradiation occurred at every 48 h during 2 weeks. Expansion was accomplished using a spatula and maintained with a triple helicoid of 0.020" stainless steel orthodontic wire. A LED light (λ850 ± 10nm, 150mW ± 10mW, spot of 0.5cm2, t=120 sec, SAEF of 18J/cm2) was applied in one point in the midpalatal suture immediately behind the upper incisors. Near infrared Raman spectroscopic analysis of the suture region was carried and data submitted to statistical analyzes (p≤0.05). Raman spectrum analysis demonstrated that irradiation increased hydroxyapatite in the midpalatal suture after expansion. The results of this indicate that LED irradiation; have a positive biomodulation contributing to the acceleration of bone formation in the midpalatal suture after expansion procedure.

  18. Complications and pregnancy outcome following uterine compression suture for postpartum haemorrhage: a single centre experience.

    PubMed

    Liu, S; Mathur, M; Tagore, S

    2014-07-01

    In the treatment of postpartum haemorrhage from uterine atony, uterine compression sutures, such as the B-Lynch suture and its modifications have a role with the advantage of preservation of the uterus for fertility. There is however, a risk that apposition of the anterior and posterior walls of the uterus will impede drainage of lochia, resulting in undesirable complications. We undertook a five-year retrospective study of all women who underwent uterine compression sutures at the KK Women's and Children's Hospital, between 2008 and 2012. In total, 23 women had uterine compression sutures during the study period, of which, nineteen women managed to conserve their uterus. Our complication rate was 25%, which included persistent vaginal discharge, pyometra and endometritis. There were three conceptions, with two successful pregnancies. Our study shows uterine compression suture to be a safe and effective alternative to avoid hysterectomy with preservation of fertility at the time of major postpartum haemorrhage. The outcome of subsequent pregnancies is reassuring. PMID:24678816

  19. Creep rupture behavior of polypropylene suture material and its applications as a time-release mechanism

    SciTech Connect

    Kusy, R.P.; Whitley, J.Q.

    1983-05-01

    The controlled failure of polypropylene (PP) sutures is studied via creep rupture tests. From plots of log time (tB) vs. stress (sigma), linear relationships are generated over the failure times of 1-1000 h. Results show that as a function of stress, the time dependence varies with irradiation dose (15, 20, 25, and 50 Mrad), irradiation atmosphere (air and vacuum), suture diameter (7-0, 6-0, 5-0, and 4-0), and test temperature (26 and 37 degrees C). For a given stress, the time to failure is least for the greatest dose in the presence of air and at the highest temperature. When suture loops are wrapped around a small wire sheave, however, failure occurs in the largest suture as much as two decades sooner than the smallest suture studied. Within the limitations stated herein, they are independent of test method, loop diameter, aging, and humidity. Consequently, after irradiation in vacuum and postirradiation heat treatment, the processed material may be stored at room temperature for at least 1 month. Such materials are advocated when the time release of a dental or medical device is required, for example, in the self-activating cleft palate appliance.

  20. Comparison of fibrin glue and suture in the healing of teat incisions in lactating goats.

    PubMed

    Alan, M; Yener, Z; Tasal, I; Bakir, B

    2008-05-01

    The aims of this study were to investigate whether fibrin glue can be used to close experimentally induced incisions of the teat (mammary papillae) in lactating goats and to compare the healing of the glued with the sutured incisions. Four clinically healthy lactating dairy goats, namely 8 mammary papillae were used. After surgical preparation of the papillae, a 3.5 cm long incision of each papilla was made through skin, muscular layer and mucosa into the papillary sinus. The wounds in the right papillae in all goats were closed with U-shaped uninterrupted 00 chromic catgut sutures. The wounds in the left papillae in all goats were closed, using fibrin glue. One incision was seen to be dehisced and fistulous one day after in fibrin glued teats. The animals were slaughtered 8 days after surgical manipulation. The mammary papillae were removed and examined in the viewpoint on gross and microscopic findings. The healing of wounds was slower and feeble in glued mammary papillary incisions, however faster and stronger in sutured incisions on day 8 after operations. But, available outcomes like less tissue thickness and positive cosmetic results could be obtained byfibrin glue used on mammary papillary incisions, which are very important for teats to be milked by hand and milking machine. Results suggest that it is advisable to use only one or two simple interrupted sutures in teat incisions glued with fibrin to prevent the dehiscence but with a more reliable healing than the sutured incisions. PMID:18547021