  1. Hyperpolarized 129Xe magnetic resonance imaging of a rat model of transient Ischemic Stroke

    NASA Astrophysics Data System (ADS)

    Walvick, Ronn P.; Bastan, Birgul; Reno, Austin; Mansour, Joey; Sun, Yanping; Zhou, Xin; Mazzani, Mary; Fisher, Marc; Sotak, Christopher H.; Albert, Mitchell S.

    2009-02-01

    Ischemic stroke accounts for nearly 80% of all stroke cases. Although proton diffusion and perfusion magnetic resonance imaging (MRI) are the gold standards in ischemic stroke diagnostics, the use of hyperpolarized 129Xe MRI has a potential role to contribute to the diagnostic picture. The highly lipophilic hyperpolarized 129Xe can be non-invasively delivered via inhalation into the lungs where it is dissolved into the blood and delivered to other organs such as the brain. As such, we expect hyperpolarized 129Xe to act as a perfusion tracer which will result in a signal deficit in areas of blood deprived tissue. In this work, we present imaging results from an animal model of transient ischemic stroke characterized through 129Xe MRI. In this model, a suture is used to occlude the middle cerebral artery (MCA) in the rat brain, thus causing an ischemic event. After a period of MCA occlusion, the suture can then be removed to reperfuse the ischemic area. During the ischemic phase of the stroke, a signal void was observed in the MCA territory; which was subsequently restored by normal 129Xe MRI signal once perfusion was reinstated. Further, a higher resolution one-dimensional chemical shift image shows a sharp signal drop in the area of ischemia. Validation of ischemic damage was shown through both proton diffusion-weighted MRI (DWI) and by 2,3,5-triphenyltetrazoliumchloride (TTC) staining. The results show the potential of 129Xe to act as a perfusion tracer; information that may add to the diagnostic and prognostic utility of the clinical picture of stroke.

  2. {sup 129}Xe nuclear magnetic resonance studies of xenon in zeolite CaA.

    SciTech Connect

    Jameson, C. J.; Jameson, A. K.; Gerald, R. E., II; de Dios, A. C.; Chemical Engineering; Univ. of Illinois at Chicago; Loyola Univ.

    1992-02-01

    The average {sup 129}Xe nuclear magnetic resonance (NMR) chemical shift for xenon atoms in alpha cages of zeolite CaA is observed in a single peak dependent on xenon loading ({l_angle}n{r_angle} = 0.5-8.9 Xe atoms/alpha cage) and temperature (240-360 K). The general increase of the shift with increasing average number of xenon atoms per alpha cage is shown to be due largely to the changing distribution of occupancies with increasing {l_angle}n{r_angle}, coupled with increasing increments in the chemical shifts of Xe{sub n} with increasing n. Except at the highest loadings, the results obtained for xenon in CaA are predicted nicely on the basis of {delta}{sub av}(T) = (1/{l_angle}n{r_angle}){Sigma}{sub n}n{delta}{sub n}(T)P{sub n}({l_angle}n{r_angle},T), where the fractions P{sub n} of alpha cages containing n Xe atoms are imported from the P{sub n} measured in xenon in zeolite NaA. The high loading data in CaA are interpreted in terms of contributions to the average {sup 129}Xe chemical shifts associated with xenon atoms in the window positions.

  3. Magnetic resonance imaging of hyperpolarized 129Xe produced by spin exchange with diode-laser pumped Cs

    NASA Astrophysics Data System (ADS)

    Levron, D.; Walter, D. K.; Appelt, S.; Fitzgerald, R. J.; Kahn, D.; Korbly, S. E.; Sauer, K. L.; Happer, W.; Earles, T. L.; Mawst, L. J.; Botez, D.; Harvey, M.; DiMarco, L.; Connolly, J. C.; Möller, H. E.; Chen, X. J.; Cofer, G. P.; Johnson, G. A.

    1998-11-01

    We report the results of experiments leading to the production of an image of a polarized 129Xe sample prepared by spin exchange with Cs, optically pumped with a spectrally narrowed 894.3 nm diode laser. Representative images of the average electron spin polarization are shown. Appreciable cesium electron polarization values were achieved, and a nuclear polarization of about 2.5% was measured for 129Xe. The absolute nuclear polarization was measured by water-calibrated free induction decay of the nuclear magnetic resonance signal, and the polarized xenon imaged using a 2 T magnetic resonance imaging system.

  4. Abnormalities in hyperpolarized (129)Xe magnetic resonance imaging and spectroscopy in two patients with pulmonary vascular disease.

    PubMed

    Dahhan, Talal; Kaushik, Shiv S; He, Mu; Mammarappallil, Joseph G; Tapson, Victor F; McAdams, Holman P; Sporn, Thomas A; Driehuys, Bastiaan; Rajagopal, Sudarshan

    2016-03-01

    The diagnosis of pulmonary vascular disease (PVD) is usually based on hemodynamic and/or clinical criteria. Noninvasive imaging of the heart and proximal vasculature can also provide useful information. An alternate approach to such criteria in the diagnosis of PVD is to image the vascular abnormalities in the lungs themselves. Hyperpolarized (HP) (129)Xe magnetic resonance imaging (MRI) is a novel technique for assessing abnormalities in ventilation and gas exchange in the lungs. We applied this technique to two patients for whom there was clinical suspicion of PVD. Two patients who had significant hypoxemia and dyspnea with no significant abnormalities on computed tomography imaging or ventilation-perfusion scan and only mild or borderline pulmonary arterial hypertension at catheterization were evaluated. They underwent HP (129)Xe imaging and subsequently had tissue diagnosis obtained from lung pathology. In both patients, HP (129)Xe imaging demonstrated normal ventilation but markedly decreased gas transfer to red blood cells with focal defects on imaging, a pattern distinct from those previously described for idiopathic pulmonary fibrosis or obstructive lung disease. Pathology on both patients later demonstrated severe PVD. These findings suggest that HP (129)Xe MRI may be useful in the diagnosis of PVD and monitoring response to therapy. Further studies are required to determine its sensitivity and specificity in these settings. PMID:27162620

  5. Magnetic resonance imaging of dissolved hyperpolarized 129Xe using a membrane-based continuous flow system

    NASA Astrophysics Data System (ADS)

    Amor, N.; Zänker, P. P.; Blümler, P.; Meise, F. M.; Schreiber, L. M.; Scholz, A.; Schmiedeskamp, J.; Spiess, H. W.; Münnemann, K.

    2009-11-01

    A technique for continuous production of solutions containing hyperpolarized 129Xe is explored for MRI applications. The method is based on hollow fiber membranes which inhibit the formation of foams and bubbles. A systematic analysis of various carrier agents for hyperpolarized 129Xe has been carried out, which are applicable as contrast agents for in vivo MRI. The image quality of different hyperpolarized Xe solutions is compared and MRI results obtained in a clinical as well as in a nonclinical MRI setting are provided. Moreover, we demonstrate the application of 129Xe contrast agents produced with our dissolution method for lung MRI by imaging hyperpolarized 129Xe that has been both dissolved in and outgassed from a carrier liquid in a lung phantom, illustrating its potential for the measurement of lung perfusion and ventilation.

  6. Resonance technique to probe 129Xe surface interactions

    NASA Astrophysics Data System (ADS)

    Sauer, K. L.; Fitzgerald, R. J.; Happer, W.

    1999-03-01

    We describe a resonance technique to probe the coupling between two spin systems at low magnetic fields. With the use of a single rotating magnetic field we match the Rabi frequency of one spin to the Larmor frequency of a second, thereby affecting the T1 of the second spin species. We have used this technique to demonstrate the contribution of coupling to surface protons to the relaxation of gaseous and liquid laser-polarized 129Xe.

  7. Magnetic decoupling of 129Xe-Rb and 129Xe-Cs binary spin exchange

    NASA Astrophysics Data System (ADS)

    Jau, Yuan-Yu; Kuzma, Nicholas N.; Happer, William

    2003-02-01

    We report calculations of the magnetic decoupling of the nuclear spin relaxation rate of 129Xe atoms caused by binary collisions with Rb or Cs atoms in a gas. A semiclassical approximation, using a classical path for the collision and treating the spin interactions quantum mechanically, gives results that differ by no more than 2% from calculations with the distorted-wave Born approximation. Both computational methods show that the relaxation rate decreases substantially for magnetic fields of a few tens of teslas. For 129Xe-Rb, where recent experimental measurements are available, the calculated rate coefficients at the experimental field of 9.4 T are about 80% of the calculated values at zero field. At 9.4 T, the calculated rate coefficient for 129Xe-Rb is about one-half of the experimentally observed value. This discrepancy is probably due to inaccuracies in the van der Waals and spin-dependent potentials used in the calculations.

  8. Nuclear spin resonance of (129)Xe doped with O(2).

    PubMed

    McNabb, J W; Balakishiyeva, D N; Honig, A

    2007-10-01

    Spin-lattice relaxation of (129)Xe nuclei in solid natural xenon has been investigated in detail over a large range of paramagnetic O(2) impurity concentrations. Direct measurements of the ground state magnetic properties of the O(2) are difficult because the ESR (electron spin resonance) lines of O(2) are rather unstructured, but NMR measurements in the liquid helium temperature region (1.4-4 K) are very sensitive to the effective magnetic moments associated with the spin 1 Zeeman levels of the O(2) molecules and to the O(2) magnetic relaxation. From these measurements, the value of the D[Sz(2)-(1/3)S(2)] spin-Hamiltonian term of the triplet spin ground state of O(2) can be determined. The temperature and magnetic field dependence of the measured paramagnetic O(2)-induced excess line width of the (129)Xe NMR signal agree well with the theoretical model with the spin-Hamiltonian D=0.19 meV (2.3 K), and with the reasonable assumption that the E[S(x)(2)-S(y)(2)] spin-Hamiltonian term is close to 0 meV. An anomalous temperature dependence between 1.4 K and 4.2K of the (129)Xe spin-lattice relaxation rate, T(1n)(-1)(T), is also accounted for by our model. Using an independent determination of the true O(2) concentration in the Xe-O(2) solid, the effective spin lattice relaxation time (which will be seen to be transition dependent) of the O(2) at 2.3 K and 0.96 T is determined to be approximately 1.4 x 10(-8)s. The experimental results, taken together with the relaxation model, suggest routes for bringing highly spin-polarized (129)Xe from the low temperature condensed phase to higher temperatures without excessive depolarization. PMID:17689279

  9. Detection of radiation induced lung injury in rats using dynamic hyperpolarized {sup 129}Xe magnetic resonance spectroscopy

    SciTech Connect

    Fox, Matthew S.; Ouriadov, Alexei; Hegarty, Elaine; Thind, Kundan; Wong, Eugene; Hope, Andrew; Santyr, Giles E.

    2014-07-15

    Purpose: Radiation induced lung injury (RILI) is a common side effect for patients undergoing thoracic radiation therapy (RT). RILI can lead to temporary or permanent loss of lung function and in extreme cases, death. Combining functional lung imaging information with conventional radiation treatment plans may lead to more desirable treatment plans that reduce lung toxicity and improve the quality of life for lung cancer survivors. Magnetic Resonance Imaging of the lung following inhalation of hyperpolarized{sup 129}Xe may provide a useful nonionizing approach for probing changes in lung function and structure associated with RILI before, during, or after RT (early and late time-points). Methods: In this study, dynamic{sup 129}Xe MR spectroscopy was used to measure whole-lung gas transfer time constants for lung tissue and red blood cells (RBC), respectively (T{sub Tr-tissue} and T{sub Tr-RBC}) in groups of rats at two weeks and six weeks following 14 Gy whole-lung exposure to radiation from a {sup 60}Co source. A separate group of six healthy age-matched rats served as a control group. Results: T{sub Tr-tissue} values at two weeks post-irradiation (51.6 ± 6.8 ms) were found to be significantly elevated (p < 0.05) with respect to the healthy control group (37.2 ± 4.8 ms). T{sub Tr-RBC} did not show any significant changes between groups. T{sub Tr-tissue} was strongly correlated with T{sub Tr-RBC} in the control group (r = 0.9601 p < 0.05) and uncorrelated in the irradiated groups. Measurements of arterial partial pressure of oxygen obtained by arterial blood sampling were found to be significantly decreased (p < 0.05) in the two-week group (54.2 ± 12.3 mm Hg) compared to those from a representative control group (85.0 ± 10.0 mm Hg). Histology of a separate group of similarly irradiated animals confirmed the presence of inflammation due to radiation exposure with alveolar wall thicknesses that were significantly different (p < 0.05). At six weeks post

  10. 1H and 129Xe nuclear magnetic resonance studies of hydrogen chemisorption on supported platinum. Application to the metal dispersion and spillover.

    PubMed

    Rouabah, D; Fraissard, J

    1994-06-01

    Chemisorption of hydrogen, electron microscopy and 1H nuclear magnetic resonance (NMR) have confirmed that the chemical shift of hydrogen chemisorbed on platinum is directly related to the size of the metal particles. The influence of the hydrogen adsorbate concentration and the chemisorption temperature on the chemical shift delta H and the distribution of the hydrogen chemisorbed on these particles have been determined. This study also shows how the dispersion can be deduced from the variation of delta H with the H2 concentration and clarifies the effect of temperature on the concentration of spillover H2. 129Xe NMR of adsorbed xenon used as a probe confirmed most of the previous results. PMID:7827982

  11. Hyperfine resonances in metastable ^129Xe discharge cells

    NASA Astrophysics Data System (ADS)

    Morgan, Steven W.; Xia, Tian; Jau, Yuan-Yu; Happer, William

    2008-05-01

    We have measured the hyperfine resonance linewidths of metastable ^129Xe in electrodeless rf discharge cells. The linewidths on the order of 10 kHz for Xe pressures of a few millitorr are dominated by collisions with other Xe atoms and no buffer gases are present. Additional contributions come from collisions with the walls as well as with impurities which may be drawn off the cell walls due to the harsh plasma environment. If used for small atomic clocks, metastable noble gases could require less power and would be relatively insensitive to temperature variations when compared with alkali metal atoms.

  12. Magnetic Field Stabilization for 129Xe EDM Search Experiment

    NASA Astrophysics Data System (ADS)

    Furukawa, Takeshi; Inoue, Takeshi; Nanao, Tsubasa; Yoshimi, Akihiro; Tsuchiya, Masato; Hayashi, Hironori; Uchida, Makoto; Asahi, Koichiro

    2011-09-01

    Magnetic field stabilization is a crucial condition parameter for many kinds of ultra-high precision measurements such as a search for an electric dipole moment (EDM). The instability of magnetic field strength often arises from the drift of current flow in a solenoid coil to generate the magnetic field. For our EDM search experiment with maser oscillating diamagnetic 129Xe atoms, we have developed a new stabilized current source based on a feedback system which is devised to correct the amount of current flow measured precisely with high-precision digital multimeter and standard resistor. Using this new current source, we have successfully reduced the drifts of coil current by at least a factor of 100 compared to commercially available current sources.

  13. ^129Xe-Rb spin-exchange cross section measurement at high magnetic field

    NASA Astrophysics Data System (ADS)

    Jau, Yuan-Yu; Kuzma, N. N.; Walter, D. K.; Griffith, W. M.; Happer, W.

    2002-05-01

    We report NMR measurements of the velocity-averaged ^129Xe-Rb spin-exchange cross section <σ_exv> using isotopically enriched xenon gas in a sealed aluminosilicate cell. At 9.4 T, it is possible to detect Boltzmann polarization of xenon gas nuclei without optical pumping. Over the temperature range from 160 to 200^rcC, binary collisions with Rb atoms dominate the ^129Xe spin-relaxation rate (1/T_1) through spin-exchange. Our data show that the spin-exchange contribution of van der Waals RbXe molecules at high magnetic field is very small compared to the contribition of binary collisions. From the observed linear dependence of 1/T1 on Rb density, we extract the value <σ_exv>=1.720.29× 10-16 cm^3/sec at 180^rcC and 9.4 T, where we deduce the Rb number density from our Faraday rotation measurements. In addition, we discuss a theoretical prediction of <σ_exv> based on our numerical computations and compare it to the experimental result.

  14. Optical hyperpolarization and NMR detection of 129Xe on a microfluidic chip

    NASA Astrophysics Data System (ADS)

    Jiménez-Martínez, Ricardo; Kennedy, Daniel J.; Rosenbluh, Michael; Donley, Elizabeth A.; Knappe, Svenja; Seltzer, Scott J.; Ring, Hattie L.; Bajaj, Vikram S.; Kitching, John

    2014-05-01

    Optically hyperpolarized 129Xe gas has become a powerful contrast agent in nuclear magnetic resonance (NMR) spectroscopy and imaging, with applications ranging from studies of the human lung to the targeted detection of biomolecules. Equally attractive is its potential use to enhance the sensitivity of microfluidic NMR experiments, in which small sample volumes yield poor sensitivity. Unfortunately, most 129Xe polarization systems are large and non-portable. Here we present a microfabricated chip that optically polarizes 129Xe gas. We have achieved 129Xe polarizations >0.5% at flow rates of several microlitres per second, compatible with typical microfluidic applications. We employ in situ optical magnetometry to sensitively detect and characterize the 129Xe polarization at magnetic fields of 1 μT. We construct the device using standard microfabrication techniques, which will facilitate its integration with existing microfluidic platforms. This device may enable the implementation of highly sensitive 129Xe NMR in compact, low-cost, portable devices.

  15. Temperature-Ramped 129Xe Spin-Exchange Optical Pumping

    PubMed Central

    2015-01-01

    We describe temperature-ramped spin-exchange optical pumping (TR-SEOP) in an automated high-throughput batch-mode 129Xe hyperpolarizer utilizing three key temperature regimes: (i) “hot”—where the 129Xe hyperpolarization rate is maximal, (ii) “warm”—where the 129Xe hyperpolarization approaches unity, and (iii) “cool”—where hyperpolarized 129Xe gas is transferred into a Tedlar bag with low Rb content (<5 ng per ∼1 L dose) suitable for human imaging applications. Unlike with the conventional approach of batch-mode SEOP, here all three temperature regimes may be operated under continuous high-power (170 W) laser irradiation, and hyperpolarized 129Xe gas is delivered without the need for a cryocollection step. The variable-temperature approach increased the SEOP rate by more than 2-fold compared to the constant-temperature polarization rate (e.g., giving effective values for the exponential buildup constant γSEOP of 62.5 ± 3.7 × 10–3 min–1 vs 29.9 ± 1.2 × 10–3 min–1) while achieving nearly the same maximum %PXe value (88.0 ± 0.8% vs 90.1% ± 0.8%, for a 500 Torr (67 kPa) Xe cell loading—corresponding to nuclear magnetic resonance/magnetic resonance imaging (NMR/MRI) enhancements of ∼3.1 × 105 and ∼2.32 × 108 at the relevant fields for clinical imaging and HP 129Xe production of 3 T and 4 mT, respectively); moreover, the intercycle “dead” time was also significantly decreased. The higher-throughput TR-SEOP approach can be implemented without sacrificing the level of 129Xe hyperpolarization or the experimental stability for automation—making this approach beneficial for improving the overall 129Xe production rate in clinical settings. PMID:25008290

  16. Temperature-ramped (129)Xe spin-exchange optical pumping.

    PubMed

    Nikolaou, Panayiotis; Coffey, Aaron M; Barlow, Michael J; Rosen, Matthew S; Goodson, Boyd M; Chekmenev, Eduard Y

    2014-08-19

    We describe temperature-ramped spin-exchange optical pumping (TR-SEOP) in an automated high-throughput batch-mode (129)Xe hyperpolarizer utilizing three key temperature regimes: (i) "hot"-where the (129)Xe hyperpolarization rate is maximal, (ii) "warm"-where the (129)Xe hyperpolarization approaches unity, and (iii) "cool"-where hyperpolarized (129)Xe gas is transferred into a Tedlar bag with low Rb content (<5 ng per ∼1 L dose) suitable for human imaging applications. Unlike with the conventional approach of batch-mode SEOP, here all three temperature regimes may be operated under continuous high-power (170 W) laser irradiation, and hyperpolarized (129)Xe gas is delivered without the need for a cryocollection step. The variable-temperature approach increased the SEOP rate by more than 2-fold compared to the constant-temperature polarization rate (e.g., giving effective values for the exponential buildup constant γSEOP of 62.5 ± 3.7 × 10(-3) min(-1) vs 29.9 ± 1.2 × 10(-3) min(-1)) while achieving nearly the same maximum %PXe value (88.0 ± 0.8% vs 90.1% ± 0.8%, for a 500 Torr (67 kPa) Xe cell loading-corresponding to nuclear magnetic resonance/magnetic resonance imaging (NMR/MRI) enhancements of ∼3.1 × 10(5) and ∼2.32 × 10(8) at the relevant fields for clinical imaging and HP (129)Xe production of 3 T and 4 mT, respectively); moreover, the intercycle "dead" time was also significantly decreased. The higher-throughput TR-SEOP approach can be implemented without sacrificing the level of (129)Xe hyperpolarization or the experimental stability for automation-making this approach beneficial for improving the overall (129)Xe production rate in clinical settings. PMID:25008290

  17. Development of high-homogeneity magnetic field coil for 129Xe EDM experiment

    NASA Astrophysics Data System (ADS)

    Sakamoto, Y.; Bidinosti, C. P.; Ichikawa, Y.; Sato, T.; Ohtomo, Y.; Kojima, S.; Funayama, C.; Suzuki, T.; Tsuchiya, M.; Furukawa, T.; Yoshimi, A.; Ino, T.; Ueno, H.; Matsuo, Y.; Fukuyama, T.; Asahi, K.

    2015-04-01

    We search for 129Xe EDM by using an active nuclear spin maser. In this experiment, the amplitude of the maser oscillation signal is one of the most important parameters that eventually determine the frequency precision. The amplitude is proportional to the ratio of the transverse spin relaxation time T 2 to the effective longitudinal spin relaxation time . In particular, for a spin maser of 3He (a co-magnetometer) for which typically reaches ˜50 h, a long T 2 is needed. T 2 depends on the homogeneity of the magnetic field which is applied with coils in order to keep the spins under precession. In the present report, we discuss on the design and construction of a new coil which provided a root-mean square (rms) field gradient of less than 5.0 μG/cm. The result of the field measurement has shown that the field gradient in the cell fulfills the target condition , and in fact T 2 of 3He has been measured to be as long as 11,000 s.

  18. Transverse spin relaxation and diffusion-constant measurements of spin-polarized 129Xe nuclei in the presence of a magnetic field gradient

    NASA Astrophysics Data System (ADS)

    Liu, Xiaohu; Chen, Chang; Qu, Tianliang; Yang, Kaiyong; Luo, Hui

    2016-04-01

    The presence of a magnetic field gradient in a sample cell containing spin-polarized 129Xe atoms will cause an increased relaxation rate. We measured the transverse spin relaxation time of 129Xe verse the applied magnetic field gradient and the cell temperature. We then compared the different transverse spin relaxation behavior of dual isotopes of xenon (129Xe and 131Xe) due to magnetic field gradient in the same cell. The experiment results show the residual magnetic field gradient can be measured and compensated by applying a negative magnetic gradient in the sample cell. The transverse spin relaxation time of 129Xe could be increased 2–7 times longer when applying an appropriate magnetic field gradient. The experiment results can also be used to determine the diffusion constant of 129Xe in H2 and N2 to be 0.4 ± 0.26 cm2/sec and 0.12 ± 0.02 cm2/sec. The results are close with theoretical calculation.

  19. Transverse spin relaxation and diffusion-constant measurements of spin-polarized 129Xe nuclei in the presence of a magnetic field gradient.

    PubMed

    Liu, Xiaohu; Chen, Chang; Qu, Tianliang; Yang, Kaiyong; Luo, Hui

    2016-01-01

    The presence of a magnetic field gradient in a sample cell containing spin-polarized (129)Xe atoms will cause an increased relaxation rate. We measured the transverse spin relaxation time of (129)Xe verse the applied magnetic field gradient and the cell temperature. We then compared the different transverse spin relaxation behavior of dual isotopes of xenon ((129)Xe and (131)Xe) due to magnetic field gradient in the same cell. The experiment results show the residual magnetic field gradient can be measured and compensated by applying a negative magnetic gradient in the sample cell. The transverse spin relaxation time of (129)Xe could be increased 2-7 times longer when applying an appropriate magnetic field gradient. The experiment results can also be used to determine the diffusion constant of (129)Xe in H2 and N2 to be 0.4 ± 0.26 cm(2)/sec and 0.12 ± 0.02 cm(2)/sec. The results are close with theoretical calculation. PMID:27049237

  20. Transverse spin relaxation and diffusion-constant measurements of spin-polarized 129Xe nuclei in the presence of a magnetic field gradient

    PubMed Central

    Liu, Xiaohu; Chen, Chang; Qu, Tianliang; Yang, Kaiyong; Luo, Hui

    2016-01-01

    The presence of a magnetic field gradient in a sample cell containing spin-polarized 129Xe atoms will cause an increased relaxation rate. We measured the transverse spin relaxation time of 129Xe verse the applied magnetic field gradient and the cell temperature. We then compared the different transverse spin relaxation behavior of dual isotopes of xenon (129Xe and 131Xe) due to magnetic field gradient in the same cell. The experiment results show the residual magnetic field gradient can be measured and compensated by applying a negative magnetic gradient in the sample cell. The transverse spin relaxation time of 129Xe could be increased 2–7 times longer when applying an appropriate magnetic field gradient. The experiment results can also be used to determine the diffusion constant of 129Xe in H2 and N2 to be 0.4 ± 0.26 cm2/sec and 0.12 ± 0.02 cm2/sec. The results are close with theoretical calculation. PMID:27049237

  1. Observation of hyperfine mixing in measurements of a magnetic octupole decay in isotopically pure nickel-like 129Xe and 132Xe ions

    SciTech Connect

    Trabert, E; Beiersdorfer, P; Brown, G V

    2006-12-21

    We present measurements of high statistical significance of the rate of the magnetic octupole (M3) decay in nickel-like ions of isotopically pure {sup 129}Xe and {sup 132}Xe. On {sup 132}Xe, an isotope with zero nuclear spin and therefore without hyperfine structure, the lifetime of the metastable level was established as (15.06 {+-} 0.24) ms. On {sup 129}Xe, an additional fast (2.7 {+-} 0.1 ms) decay component was established that represents hyperfine mixing with a level that decays by electric quadrupole (E2) radiation.

  2. In Vivo MR Imaging of Pulmonary Perfusion and Gas Exchange in Rats via Continuous Extracorporeal Infusion of Hyperpolarized 129Xe

    PubMed Central

    Cleveland, Zackary I.; Möller, Harald E.; Hedlund, Laurence W.; Nouls, John C.; Freeman, Matthew S.; Qi, Yi; Driehuys, Bastiaan

    2012-01-01

    Background Hyperpolarized (HP) 129Xe magnetic resonance imaging (MRI) permits high resolution, regional visualization of pulmonary ventilation. Additionally, its reasonably high solubility (>10%) and large chemical shift range (>200 ppm) in tissues allow HP 129Xe to serve as a regional probe of pulmonary perfusion and gas transport, when introduced directly into the vasculature. In earlier work, vascular delivery was accomplished in rats by first dissolving HP 129Xe in a biologically compatible carrier solution, injecting the solution into the vasculature, and then detecting HP 129Xe as it emerged into the alveolar airspaces. Although easily implemented, this approach was constrained by the tolerable injection volume and the duration of the HP 129Xe signal. Methods and Principal Findings Here, we overcome the volume and temporal constraints imposed by injection, by using hydrophobic, microporous, gas-exchange membranes to directly and continuously infuse 129Xe into the arterial blood of live rats with an extracorporeal (EC) circuit. The resulting gas-phase 129Xe signal is sufficient to generate diffusive gas exchange- and pulmonary perfusion-dependent, 3D MR images with a nominal resolution of 2×2×2 mm3. We also show that the 129Xe signal dynamics during EC infusion are well described by an analytical model that incorporates both mass transport into the blood and longitudinal relaxation. Conclusions Extracorporeal infusion of HP 129Xe enables rapid, 3D MR imaging of rat lungs and, when combined with ventilation imaging, will permit spatially resolved studies of the ventilation-perfusion ratio in small animals. Moreover, EC infusion should allow 129Xe to be delivered elsewhere in the body and make possible functional and molecular imaging approaches that are currently not feasible using inhaled HP 129Xe. PMID:22363613

  3. Continuously Infusing Hyperpolarized 129Xe into Flowing Aqueous Solutions Using Hydrophobic Gas Exchange Membranes

    PubMed Central

    Cleveland, Zackary I.; Möller, Harald E.; Hedlund, Laurence W.; Driehuys, Bastiaan

    2009-01-01

    Hyperpolarized (HP) 129Xe yields high signal intensities in magnetic resonance (MR) and, through its large chemical shift range of ∼300 ppm, provides detailed information about the local chemical environment. To exploit these properties in aqueous solutions and living tissues requires the development of methods for efficiently dissolving HP 129Xe over an extended time period. To this end, we have used commercially available gas exchange modules to continuously infuse concentrated HP 129Xe into flowing liquids, including rat whole blood, for periods as long as one hour, and have demonstrated the feasibility of dissolved-phase MR imaging with sub-millimeter resolution within minutes. These modules, which exchange gases using hydrophobic microporous polymer membranes, are compatible with a variety of liquids and are suitable for infusing HP 129Xe into the bloodstream in vivo. Additionally, we have developed a detailed mathematical model of the infused HP 129Xe signal dynamics that should be useful in designing improved infusion systems that yield even higher dissolved HP 129Xe signal intensities. PMID:19702286

  4. 129Xe spin relaxation in frozen xenon

    NASA Astrophysics Data System (ADS)

    Fitzgerald, R. J.; Gatzke, M.; Fox, David C.; Cates, G. D.; Happer, W.

    1999-04-01

    We discuss the longitudinal spin relaxation of 129Xe nuclei in frozen xenon. Over a large range of temperatures and magnetic fields, the dominant spin-lattice relaxation mechanism is shown to be nuclear spin-flip Raman scattering of lattice phonons. Two closely related interactions couple the lattice phonons to the spins of 129Xe nuclei: (1) the nuclear spin-rotation interaction between nearest-neighbor atoms, and (2) the paramagnetic antishielding of the externally applied field at the site of 129Xe nuclei by the electrons of neighboring Xe atoms. We show that relaxation rates can be predicted by using measured chemical shifts of gaseous and condensed xenon. The predicted relaxation rates are in good agreement with measurements. We outline a simple way to estimate the spin-rotation coupling and paramagnetic antishielding in terms of the small perturbations of the outermost electron orbitals of one xenon atom due to a neighboring atom.

  5. Polarization of metastable 129Xe

    NASA Astrophysics Data System (ADS)

    Xia, Tian; Morgan, Steven; Jau, Yuan-Yu; Happer, William

    2008-05-01

    We have measured atomic polarization of metastable 129Xe in a pyrex cell by optical pumping, while metastability exchange optical pumping of 3He is routinely done. The atomic polarization of metastable Xe is on the order of 10%. Metastable xenon is created by electrodeless rf discharge. The hyperfine transition of metastable 129Xe is observed by microwave excitation. Atomic polarization can be demonstrated by comparison of the intensities of the transitions between different Zeeman sublevels, while pumping a specific optical transition of metastable Xe with circularly polarized light. This work offers insight into attempts to polarize 129Xe nuclei by metastability exchange optical pumping.

  6. 129Xe NMR chemical shift in Xe@C60 calculated at experimental conditions: essential role of the relativity, dynamics, and explicit solvent.

    PubMed

    Standara, Stanislav; Kulhánek, Petr; Marek, Radek; Straka, Michal

    2013-08-15

    The isotropic (129)Xe nuclear magnetic resonance (NMR) chemical shift (CS) in Xe@C60 dissolved in liquid benzene was calculated by piecewise approximation to faithfully simulate the experimental conditions and to evaluate the role of different physical factors influencing the (129)Xe NMR CS. The (129)Xe shielding constant was obtained by averaging the (129)Xe nuclear magnetic shieldings calculated for snapshots obtained from the molecular dynamics trajectory of the Xe@C60 system embedded in a periodic box of benzene molecules. Relativistic corrections were added at the Breit-Pauli perturbation theory (BPPT) level, included the solvent, and were dynamically averaged. It is demonstrated that the contribution of internal dynamics of the Xe@C60 system represents about 8% of the total nonrelativistic NMR CS, whereas the effects of dynamical solvent add another 8%. The dynamically averaged relativistic effects contribute by 9% to the total calculated (129)Xe NMR CS. The final theoretical value of 172.7 ppm corresponds well to the experimental (129)Xe CS of 179.2 ppm and lies within the estimated errors of the model. The presented computational protocol serves as a prototype for calculations of (129)Xe NMR parameters in different Xe atom guest-host systems. PMID:23703381

  7. High resolution spectroscopy and chemical shift imaging of hyperpolarized 129Xe dissolved in the human brain in vivo at 1.5 tesla

    PubMed Central

    Rao, Madhwesha; Stewart, Neil J.; Norquay, Graham; Griffiths, Paul D.

    2016-01-01

    Purpose Upon inhalation, xenon diffuses into the bloodstream and is transported to the brain, where it dissolves in various compartments of the brain. Although up to five chemically distinct peaks have been previously observed in 129Xe rat head spectra, to date only three peaks have been reported in the human head. This study demonstrates high resolution spectroscopy and chemical shift imaging (CSI) of 129Xe dissolved in the human head at 1.5 Tesla. Methods A 129Xe radiofrequency coil was built in‐house and 129Xe gas was polarized using spin‐exchange optical pumping. Following the inhalation of 129Xe gas, NMR spectroscopy was performed with spectral resolution of 0.033 ppm. Two‐dimensional CSI in all three anatomical planes was performed with spectral resolution of 2.1 ppm and voxel size 20 mm × 20 mm. Results Spectra of hyperpolarized 129Xe dissolved in the human head showed five distinct peaks at 188 ppm, 192 ppm, 196 ppm, 200 ppm, and 217 ppm. Assignment of these peaks was consistent with earlier studies. Conclusion High resolution spectroscopy and CSI of hyperpolarized 129Xe dissolved in the human head has been demonstrated. For the first time, five distinct NMR peaks have been observed in 129Xe spectra from the human head in vivo. Magn Reson Med 75:2227–2234, 2016. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. PMID:27080441

  8. Hyperpolarized (129)Xe T (1) in oxygenated and deoxygenated blood

    NASA Technical Reports Server (NTRS)

    Albert, M. S.; Balamore, D.; Kacher, D. F.; Venkatesh, A. K.; Jolesz, F. A.

    2000-01-01

    The viability of the new technique of hyperpolarized (129)Xe MRI (HypX-MRI) for imaging organs other than the lungs depends on whether the spin-lattice relaxation time, T(1), of (129)Xe is sufficiently long in the blood. In previous experiments by the authors, the T(1) was found to be strongly dependent upon the oxygenation of the blood, with T(1) increasing from about 3 s in deoxygenated samples to about 10 s in oxygenated samples. Contrarily, Tseng et al. (J. Magn. Reson. 1997; 126: 79-86) reported extremely long T(1) values deduced from an indirect experiment in which hyperpolarized (129)Xe was used to create a 'blood-foam'. They found that oxygenation decreased T(1). Pivotal to their experiment is the continual and rapid exchange of hyperpolarized (129)Xe between the gas phase (within blood-foam bubbles) and the dissolved phase (in the skin of the bubbles); this necessitated a complicated analysis to extract the T(1) of (129)Xe in blood. In the present study, the experimental design minimizes gas exchange after the initial bolus of hyperpolarized (129)Xe has been bubbled through the sample. This study confirms that oxygenation increases the T(1) of (129)Xe in blood, from about 4 s in freshly drawn venous blood, to about 13 s in blood oxygenated to arterial levels, and also shifts the red blood cell resonance to higher frequency. Copyright 2000 John Wiley & Sons, Ltd. Abbreviations used BOLD blood oxygen level dependent NOE nuclear overhouses effect PO(2) oxygen partial pressure RBC red blood cells RF radio frequency SNR signal-to-noise ratio.

  9. Near-unity nuclear polarization with an open-source 129Xe hyperpolarizer for NMR and MRI

    PubMed Central

    Nikolaou, Panayiotis; Coffey, Aaron M.; Walkup, Laura L.; Gust, Brogan M.; Whiting, Nicholas; Newton, Hayley; Barcus, Scott; Muradyan, Iga; Dabaghyan, Mikayel; Moroz, Gregory D.; Rosen, Matthew S.; Patz, Samuel; Barlow, Michael J.; Chekmenev, Eduard Y.; Goodson, Boyd M.

    2013-01-01

    The exquisite NMR spectral sensitivity and negligible reactivity of hyperpolarized xenon-129 (HP129Xe) make it attractive for a number of magnetic resonance applications; moreover, HP129Xe embodies an alternative to rare and nonrenewable 3He. However, the ability to reliably and inexpensively produce large quantities of HP129Xe with sufficiently high 129Xe nuclear spin polarization (PXe) remains a significant challenge—particularly at high Xe densities. We present results from our “open-source” large-scale (∼1 L/h) 129Xe polarizer for clinical, preclinical, and materials NMR and MRI research. Automated and composed mostly of off-the-shelf components, this “hyperpolarizer” is designed to be readily implementable in other laboratories. The device runs with high resonant photon flux (up to 200 W at the Rb D1 line) in the xenon-rich regime (up to 1,800 torr Xe in 500 cc) in either single-batch or stopped-flow mode, negating in part the usual requirement of Xe cryocollection. Excellent agreement is observed among four independent methods used to measure spin polarization. In-cell PXe values of ∼90%, ∼57%, ∼50%, and ∼30% have been measured for Xe loadings of ∼300, ∼500, ∼760, and ∼1,570 torr, respectively. PXe values of ∼41% and ∼28% (with ∼760 and ∼1,545 torr Xe loadings) have been measured after transfer to Tedlar bags and transport to a clinical 3 T scanner for MR imaging, including demonstration of lung MRI with a healthy human subject. Long “in-bag” 129Xe polarization decay times have been measured (T1 ∼38 min and ∼5.9 h at ∼1.5 mT and 3 T, respectively)—more than sufficient for a variety of applications. PMID:23946420

  10. Hyperpolarized 129Xe MRI of the Human Lung

    PubMed Central

    Mugler, John P.; Altes, Talissa A.

    2012-01-01

    By permitting direct visualization of the airspaces of the lung, MR imaging using hyperpolarized gases provides unique strategies for evaluating pulmonary structure and function. Although the vast majority of research in humans has been performed using hyperpolarized 3He, recent contraction in the supply of 3He and consequent increases in price have turned attention to the alternative agent, hyperpolarized 129Xe. Compared to 3He, 129Xe yields reduced signal due to its smaller magnetic moment. Nonetheless, taking advantage of advances in gas-polarization technology, recent studies in humans using techniques for measuring ventilation, diffusion, and partial pressure of oxygen have demonstrated results for hyperpolarized 129Xe comparable to those previously demonstrated using hyperpolarized 3He. In addition, xenon has the advantage of readily dissolving in lung tissue and blood following inhalation, which makes hyperpolarized 129Xe particularly attractive for exploring certain characteristics of lung function, such as gas exchange and uptake, which cannot be accessed using 3He. Preliminary results from methods for imaging 129Xe dissolved in the human lung suggest that these approaches will provide new opportunities for quantifying relationships among gas delivery, exchange, and transport, and thus show substantial potential to broaden our understanding of lung disease. Finally, recent changes in the commercial landscape of the hyperpolarized-gas field now make it possible for this innovative technology to move beyond the research lab. PMID:23355432

  11. High-field measurement of the 129Xe-Rb spin-exchange rate due to binary collisions

    NASA Astrophysics Data System (ADS)

    Jau, Yuan-Yu; Kuzma, Nicholas N.; Happer, William

    2002-11-01

    We have measured the binary spin-exchange rate coefficient for collisions between Rb and 129Xe atoms at a magnetic field B=9.4 T and in the temperature range 160129Xe is dominated by 129Xe-Rb binary collisions. We measured 1/T1 using the methods of conventional nuclear magnetic resonance, with no spin enhancement by optical pumping. At the high magnetic field and large gas pressures used in this work, the contribution of 129Xe-Rb molecules to the spin-exchange rate was less than 0.1% of the binary-collision rate. The Rb atomic number density [Rb] was measured directly from the large Faraday rotation of the polarization of near-resonant light passing through the sample cells. The rate coefficient is κ=d(1/T1)/d [Rb]=(1.75+/-0.12)×10-16 cm3/s.

  12. Measurement of 129Xe -Cs binary spin-exchange rate coefficient

    NASA Astrophysics Data System (ADS)

    Jau, Yuan-Yu; Kuzma, Nicholas N.; Happer, William

    2004-06-01

    We report the first measurement of the spin-exchange rate coefficient for binary collisions between Cs and 129Xe atoms in the temperature range 110magnetic field. Under these conditions, binary spin-exchange collisions dominate the longitudinal nuclear spin-relaxation rate 1/ T1 of 129Xe gas. We measured 1/ T1 of a thermally polarized Xe gas using the saturation-recovery of conventional nuclear magnetic resonance. We also directly measured the Cs atomic number density [Cs] by using Faraday rotation of the linear polarization of a probing laser beam passing through the sample. The measured rate coefficient is κ (9.4 T) = d (1/ T1 ) / d [Cs] = (2.81±0.2) × 10-16 cm3 /s , which is about a factor of 1.6 higher than the previously measured spin-exchange rate coefficient of 129Xe -Rb binary collisions. Using a calculated magnetic decoupling factor, we extrapolate our result to zero magnetic field: κ (0 T) = (4.1±0.3) × 10-16 cm3 /s .

  13. A Genetically Encoded β-Lactamase Reporter for Ultrasensitive (129) Xe NMR in Mammalian Cells.

    PubMed

    Wang, Yanfei; Roose, Benjamin W; Palovcak, Eugene J; Carnevale, Vincenzo; Dmochowski, Ivan J

    2016-07-25

    Molecular imaging holds considerable promise for elucidating biological processes in normal physiology as well as disease states, but requires noninvasive methods for identifying analytes at sub-micromolar concentrations. Particularly useful are genetically encoded, single-protein reporters that harness the power of molecular biology to visualize specific molecular processes, but such reporters have been conspicuously lacking for in vivo magnetic resonance imaging (MRI). Herein, we report TEM-1 β-lactamase (bla) as a single-protein reporter for hyperpolarized (HP) (129) Xe NMR, with significant saturation contrast at 0.1 μm. Xenon chemical exchange saturation transfer (CEST) interactions with the primary allosteric site in bla give rise to a unique saturation peak at 255 ppm, well removed (≈60 ppm downfield) from the (129) Xe-H2 O peak. Useful saturation contrast was also observed for bla expressed in bacterial cells and mammalian cells. PMID:27305488

  14. 129Xe EDM Search Experiment Using Active Nuclear Spin Maser

    NASA Astrophysics Data System (ADS)

    Sato, Tomoya; Ichikawa, Yuichi; Ohtomo, Yuichi; Sakamoto, Yu; Kojima, Shuichiro; Suzuki, Takahiro; Shirai, Hazuki; Chikamori, Masatoshi; Hikota, Eri; Miyatake, Hirokazu; Nanao, Tsubasa; Suzuki, Kunifumi; Tsuchiya, Masato; Inoue, Takeshi; Furukawa, Takeshi; Yoshimi, Akihiro; Bidinosti, Christopher P.; Ino, Takashi; Ueno, Hideki; Matsuo, Yukari; Fukuyama, Takeshi; Asahi, Koichiro

    An active nuclear spin maser, which enables a precision measurement of spin precession frequency, is employed in the experimental search for permanent electric dipole moment (EDM) in the diamagnetic atom 129Xe. In order to eliminate systematic errors which limit the sensitivity of the experiment to an EDM, the following tactics are adopted: (i) 3He comagnetometry for the cancellation of long-term drifts in the external magnetic fields and (ii) double-cell geometry for the mitigation of frequency shifts due to interaction of 129Xe spin with polarized Rb atoms. In the present work, the design for the double-cell has been changed and a magnetic shield-coil system to provide a highly homogeneous magnetic field has been newly introduced. Thanks to increased polarization and longer 3He spin relaxation time, the dual-species maser of 129Xe and 3He in a double-cell geometry operated successfully. Our experiment is now at the stage of assembling these separate technical elements in order to start the measurement of 129Xe EDM in the 10-28 ecm region.

  15. Laser-polarized xenon-129 magnetic resonance spectroscopy and imaging. The development of a method for in vivo perfusion measurement

    NASA Astrophysics Data System (ADS)

    Rosen, Matthew Scot

    2001-07-01

    This thesis presents in vivo nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) studies with laser-polarized 129Xe delivered to living rats by inhalation and transported to tissue via blood flow. The results presented herein include the observation, assignment, and dynamic measurement of 129Xe resonances in the brain and body, the first one- and two-dimensional chemical-shift-resolved images of 129Xe in blood, tissue, and gas in the thorax, and the first images of 129Xe in brain tissue. These results establish that laser-polarized 129Xe can be used as a magnetic resonance tracer in vivo. NMR resonances at 0, 191, 198, and 209 ppm relative to the 129 Xe gas resonance are observed in the rat thorax and assigned to 129Xe in gas, fat, tissue, and blood respectively. Resonances at 189, 192, 195, 198, and 209 ppm are observed in the brain, and the 195 and 209 ppm resonances are assigned to 129Xe in grey matter, and blood, respectively. The design and construction of a laser-polarized 129Xe production and delivery system is described. This system produces liter-volumes of laser- polarized 129Xe by spin-exchange optical- pumping. It represented an order of magnitude increase over previously reported production volumes of polarized 129Xe. At approximately 3-7% polarization, 157 cc-atm of xenon is produced and stored as ice every 5 minutes. This reliable, effective, and simple production method for large volumes of 129Xe can be applied to other areas of research involving the use of laser-polarized noble gases. A model of the in vivo transport of laser polarized 129Xe to tissue under realistic experimental NMR conditions is described. Appropriate control of the NMR parameters is shown to allow tissue perfasion and 129Xe tissue T1 to be extracted from measurement of the steady-state 129Xe tissue signal. In vivo rodent 129Xe NMR results are used to estimate the signal-to-noise ratio of this technique, and an inhaled 30% xenon/70% O2 mixture polarized to 5

  16. Time resolved spectroscopic NMR imaging using hyperpolarized 129Xe.

    PubMed

    Han, S; Kühn, H; Häsing, F W; Münnemann, K; Blümich, B; Appelt, S

    2004-04-01

    We have visualized the melting and dissolution processes of xenon (Xe) ice into different solvents using the methods of nuclear magnetic resonance (NMR) spectroscopy, imaging, and time resolved spectroscopic imaging by means of hyperpolarized 129Xe. Starting from the initial condition of a hyperpolarized solid Xe layer frozen on top of an ethanol (ethanol/water) ice block we measured the Xe phase transitions as a function of time and temperature. In the pure ethanol sample, pieces of Xe ice first fall through the viscous ethanol to the bottom of the sample tube and then form a thin layer of liquid Xe/ethanol. The xenon atoms are trapped in this liquid layer up to room temperature and keep their magnetization over a time period of 11 min. In the ethanol/water mixture (80 vol%/20%), most of the polarized Xe liquid first stays on top of the ethanol/water ice block and then starts to penetrate into the pores and cracks of the ethanol/water ice block. In the final stage, nearly all the Xe polarization is in the gas phase above the liquid and trapped inside the pores. NMR spectra of homogeneous samples of pure ethanol containing thermally polarized Xe and the spectroscopic images of the melting process show that very high concentrations of hyperpolarized Xe (about half of the density of liquid Xe) can be stored or delivered in pure ethanol. PMID:15040986

  17. Nuclear spin-spin coupling anisotropy in the van der Waals-bonded 129Xe dimer.

    PubMed

    Jokisaari, Jukka; Vaara, Juha

    2013-07-21

    The spin-spin coupling constant, J, in the van der Waals-bonded (129)Xe-(129)Xe dimer cannot be determined experimentally because of the magnetic equivalence of the two nuclei. In contrast, the anisotropy of the coupling tensor, ΔJ, can be obtained from the so called effective dipole-dipole coupling determined in a solid state inclusion compound whose cages accommodate two xenon atoms. For the determination of the experimental ΔJ((129)Xe, (129)Xe) we exploited the data reported earlier in this journal. [D. H. Brouwer et al., Phys. Chem. Chem. Phys., 2007, 9, 1093.] The experimental value and the value obtained from relativistic first-principles computation are in perfect agreement. To the best of our knowledge this is the first investigation of spin-spin coupling anisotropy in a van der Waals-bonded system. PMID:23743998

  18. About 129Xe ∗ in meteoritic nanodiamonds

    NASA Astrophysics Data System (ADS)

    Fisenko, A. V.; Semjonova, L. F.

    2008-08-01

    The analysis of excess 129Xe in meteoritic nanodiamonds and the kinetics of its release during stepwise pyrolysis allow to suggest that (1) in the solar nebula 129I atoms were adsorbed onto nanodiamond grains and (or) chemisorbed by forming covalent bonds with carbon atoms. Most 129I atoms existed in a surface connected state, but a minor amount of them was in nanopores of the grains. At radioactive decay of 129I the formed 129Xe ( 129Xe ∗) was trapped by diamond grains due to nuclear recoil. (2) During thermal metamorphism or aqueous alteration, the surface-sited 129I atoms were basically lost. On the basis of these assumptions and calculated concentrations of 129Xe ∗ in meteoritic nanodiamonds it is shown that the minimum closing time of the I-Xe system for meteorites of different chemical classes and low petrologic types may be about one million years relative to the minimally thermally metamorphized CO3 meteorite ALHA 77307. With increasing metamorphic grade the closing time of the I-Xe system increases and can range up to several ten millions years. This tendency is in agreement with an onion-shell model of structure and cooling history of meteorite parent bodies where the temperature increases in the direction from surface to center of the asteroids.

  19. Polarization and Hyperfine Transitions of Metastable ^129Xe in Discharge Cells

    NASA Astrophysics Data System (ADS)

    Xia, Tian; Morgan, Steven; Jau, Yuan-Yu; Happer, William

    2010-03-01

    The polarization and relaxation rates of metastable ^129Xe atoms are measured with magnetic resonance spectroscopy, at both microwave frequencies, where δF = 1 transitions are induced between the sublevels, and at radiofrequencies, corresponding to δF = 0 transitions. The nuclear spin polarization of the resonant velocity group is measured to be 22±2%. However, the relaxation rate of spin polarization is much larger than the velocity changing rate, the narrow line pumping laser produces spin polarization only for atoms with resonant velocity. The relaxation of metastable xenon atoms is dominated by depolarizing collisions with ground state atoms, with lesser contributions from metastability exchange collisions. We also measure the pressure broadening coefficient of the relaxation rate by varying the temperature of the cryogenic part of the cell.

  20. Reducing Relaxation of Hyperpolarized ^129 Xe during Cryogenic Separation

    NASA Astrophysics Data System (ADS)

    Patton, B.; Kuzma, N. N.; Happer, W.

    2004-05-01

    Recent experimental results^1 indicate that the T1 relaxation time of solid ^129Xe is much shorter than previous models had predicted^2 near the xenon melting point of 161 K and at low magnetic fields. This enhanced relaxation is detrimental to commercial xenon polarizers, which cryogenically distill hyperpolarized ^129Xe from a buffer gas mixture. We have measured the fraction of xenon polarization lost during a typical cryogenic collection, using different permanent magnets to vary the holding field from 700 gauss to over a tesla. The results indicate that using a stronger permanent magnet around the cryo-trap is a simple way to increase the final polarization of the pure xenon gas. An additional experiment was conducted in order to determine whether the majority of the xenon relaxation occurs throughout accumulation (possibly as a result of temperature inhomogeneities within the frozen sample) or during the brief thawing time. In pinpointing the polarization loss, this research may suggest new designs for xenon polarizers. 1. Kuzma et al., Phys. Rev. Lett. 88, 147602 (2002). 2. Fitzgerald et al., Phys. Rev. B 59, 8795 (1999).

  1. NMR of laser-polarized 129Xe in blood foam

    NASA Technical Reports Server (NTRS)

    Tseng, C. H.; Peled, S.; Nascimben, L.; Oteiza, E.; Walsworth, R. L.; Jolesz, F. A.

    1997-01-01

    Laser-polarized 129Xe dissolved in a foam preparation of fresh human blood was investigated. The NMR signal of 129Xe dissolved in blood was enhanced by creating a foam in which the dissolved 129Xe exchanged with a large reservoir of gaseous laser-polarized 129Xe. The dissolved 129Xe T1 in this system was found to be significantly shorter in oxygenated blood than in deoxygenated blood. The T1 of 129Xe dissolved in oxygenated blood foam was found to be approximately 21 (+/-5) s, and in deoxygenated blood foam to be greater than 40 s. To understand the oxygenation trend, T1 measurements were also made on plasma and hemoglobin foam preparations. The measurement technique using a foam gas-liquid exchange interface may also be useful for studying foam coarsening and other liquid physical properties.

  2. Theory of spin-exchange optical pumping of 3He and 129Xe

    NASA Astrophysics Data System (ADS)

    Appelt, S.; Baranga, A. Ben-Amar; Erickson, C. J.; Romalis, M. V.; Young, A. R.; Happer, W.

    1998-08-01

    We present a comprehensive theory of nuclear spin polarization of 3He and 129Xe gases by spin-exchange collisions with optically pumped alkali-metal vapors. The most important physical processes considered are (1) spin-conserving spin-exchange collisions between like or unlike alkali-metal atoms; (2) spin-destroying collisions of the alkali-metal atoms with each other and with buffer-gas atoms; (3) electron-nuclear spin-exchange collisions between alkali-metal atoms and 3He or 129Xe atoms; (4) spin interactions in van der Waals molecules consisting of a Xe atom bound to an alkali-metal atom; (5) optical pumping by laser photons; (6) spatial diffusion. The static magnetic field is assumed to be small enough that the nuclear spin of the alkali-metal atom is well coupled to the electron spin and the total spin is very nearly a good quantum number. Conditions appropriate for the production of large quantities of spin-polarized 3He or 129Xe gas are assumed, namely, atmospheres of gas pressure and nearly complete quenching of the optically excited alkali-metal atoms by collisions with N2 or H2 gas. Some of the more important results of this work are as follows: (1) Most of the pumping and relaxation processes are sudden with respect to the nuclear polarization. Consequently, the steady-state population distribution of alkali-metal atoms is well described by a spin temperature, whether the rate of spin-exchange collisions between alkali-metal atoms is large or small compared to the optical pumping rate or the collisional spin-relaxation rates. (2) The population distributions that characterize the response to sudden changes in the intensity of the pumping light are not described by a spin temperature, except in the limit of very rapid spin exchange. (3) Expressions given for the radio-frequency (rf) resonance linewidths and areas can be used to make reliable estimates of the local spin polarization of the alkali-metal atoms. (4) Diffusion effects for these high

  3. EDM measurement in 129Xe atom using dual active feedback nuclear spin maser

    NASA Astrophysics Data System (ADS)

    Sato, T.; Ichikawa, Y.; Ohtomo, Y.; Sakamoto, Y.; Kojima, S.; Funayama, C.; Suzuki, T.; Chikamori, M.; Hikota, E.; Tsuchiya, M.; Furukawa, T.; Yoshimi, A.; Bidinosti, C. P.; Ino, T.; Ueno, H.; Matsuo, Y.; Fukuyama, T.; Asahi, K.

    2015-04-01

    The technique of an active nuclear spin maser is adopted in the search for electric dipole moment in a diamagnetic atom 129Xe. In order to reduce systematic uncertainties arising from long-term drifts of the external magnetic field and from the contact interaction between longitudinal polarized Rb atoms and 129Xe spin, a 3He comagnetometer with a double-cell geometry was employed. The remaining shift, which turned out to show some correlation with the cell temperature, was mitigated by stabilizing the cell temperature. As a result, the frequency drift of the 129Xe maser was reduced from 12 mHz to 700 μHz, and the determination precision of frequency of 8.7 nHz was obtained for a 2×104 s measurement time using the double-cell geometry cell.

  4. Search for electric dipole moment in 129Xe atom using active nuclear spin maser

    NASA Astrophysics Data System (ADS)

    Ichikawa, Y.; Chikamori, M.; Ohtomo, Y.; Hikota, E.; Sakamoto, Y.; Suzuki, T.; Bidinosti, C. P.; Inoue, T.; Furukawa, T.; Yoshimi, A.; Suzuki, K.; Nanao, T.; Miyatake, H.; Tsuchiya, M.; Yoshida, N.; Shirai, H.; Ino, T.; Ueno, H.; Matsuo, Y.; Fukuyama, T.; Asahi, K.

    2014-03-01

    An experimental search for an electric dipole moment in the diamagnetic atom 129Xe is in progress through the precision measurement of spin precession frequency using an active nuclear spin maser. A 3He comagnetometer has been incorporated into the active spin maser system in order to cancel out the long-term drifts in the external magnetic field. Also, a double-cell geometry has been adopted in order to suppress the frequency shifts due to interaction with polarized Rb atoms. The first EDM measurement with the 129Xe active spin maser and the 3He comagnetometer has been conducted.

  5. NMR spectroscopy of hyperpolarized ^129Xe at high fields: Maintaining spin polarization after optical pumping.

    NASA Astrophysics Data System (ADS)

    Patton, Brian; Kuzma, Nicholas N.; Lisitza, Natalia V.; Happer, William

    2003-05-01

    Spin-polarized ^129Xe has become an invaluable tool in nuclear magnetic resonance research, with applications ranging from medical imaging to high-resolution spectroscopy. High-field NMR studies using hyperpolarized xenon as a spectroscopic probe benefit from the high signal-to-noise ratios and large chemical shifts typical of optically-pumped noble gases. The experimental sensitivity is ultimately determined by the absolute polarization of the xenon in the sample, which can be substantially decreased during purification and transfer. NMR of xenon at high fields (9.4 Tesla) will be discussed, and potential mechanisms of spin relaxation during the distillation, storage(N. N. Kuzma, B. Patton, K. Raman, and W. Happer, Phys. Rev. Lett. 88), 147602 (2002)., and delivery of hyperpolarized xenon will be analyzed.

  6. Fast Nuclear Spin Relaxation in Hyperpolarized Solid 129Xe

    NASA Astrophysics Data System (ADS)

    Kuzma, N. N.; Patton, B.; Raman, K.; Happer, W.

    2002-04-01

    We report extensive new measurements of the longitudinal relaxation time T1 of 129Xe nuclear spins in solid xenon. For temperatures T<120 K and magnetic fields B>0.05 T, we found T1 on the order of hours, in good agreement with previous measurements and with the predicted phonon-scattering limit for the spin-rotation interaction. For T>120 K, our new data show that T1 can be much shorter than the phonon scattering limit. For B = 0.06 T, a field often used to accumulate hyperpolarized xenon, T1 is ~6 s near the Xe melting point Tm = 161.4 K. From T = 50 K to Tm, the new data are in excellent agreement with the theoretical prediction that the relaxation is due to (i) modulation of the spin-rotation interaction by phonons, and (ii) modulation of the dipole-dipole interaction by vacancy diffusion.

  7. High-field measurement of the 129Xe-Cs binary spin-exchange rate coefficient

    NASA Astrophysics Data System (ADS)

    Jau, Yuan-Yu; Kuzma, Nicholas N.; Happer, William

    2004-03-01

    We report the first measurement of the binary spin-exchange rate coefficient κ in the ^129Xe-Cs system. Data were taken using ^129Xe NMR in glass cells containing isotopically enriched xenon gas at pressures on the order of atmospheres and a small amount of liquid Cs metal, in the temperature range from 120 to 140^rcC and at a magnetic field of 9.4 T. The contribution of CsXe van der Waals molecules to spin exchange should have been nearly eliminated by the high magnetic field, as confirmed by our measurements of the ^129Xe longitudinal relaxation time T1 in a series of cells with various densities of xenon. The Cs atomic number density [Cs] was controlled by the cell temperature, and was experimentally determined by analysis of the Faraday rotation of linearly polarized probe laser light. We measured κ = d (T_1-1)/d[Cs]= (2.81± 0.2) × 10-16 cm^3 s-1 . This is about 60% larger than the previously measured rate coefficient for the ^129Xe-Rb system(Y.-Y. Jau, N. N. Kuzma, and W. Happer, Phys. Rev. A 66, 052710 (2002).), κ =d (T_1-1)/d[Rb]= (1.75± 0.12) × 10-16 cm^3 s-1 . A comparison with theory(Y.-Y. Jau, N. N. Kuzma, and W. Happer, Phys. Rev. A 67, 022720 (2003).) will be discussed.

  8. Nuclear spin relaxation of {sup 129}Xe due to persistent xenon dimers

    SciTech Connect

    Berry-Pusey, B. N.; Anger, B. C.; Laicher, G.; Saam, B.

    2006-12-15

    We have measured longitudinal nuclear relaxation rates of {sup 129}Xe in Xe-N{sub 2} mixtures at densities below 0.5 amagats in a magnetic field of 8.0 T. We find that intrinsic spin relaxation in this regime is principally due to fluctuations in the intramolecular spin-rotation (SR) and chemical-shift-anisotropy (CSA) interactions, mediated by the formation of {sup 129}Xe-Xe persistent dimers. Our results are consistent with previous work done in one case at much lower applied fields where the CSA interaction is negligible and in another case at much higher gas densities where transient xenon dimers mediate the interactions. We have verified that a large applied field suppresses the persistent-dimer mechanism, consistent with standard relaxation theory, allowing us to measure room-temperature gas-phase relaxation times T{sub 1} for {sup 129}Xe greater than 25 h at 8.0 T. These data also yield a maximum possible low-field T{sub 1} for pure xenon gas at room temperature of 5.45{+-}0.2 h. The coupling strengths for the SR and CSA interactions that we extract are in fair agreement with estimates based both on previous experimental work and on ab initio calculations. Our results have potential implications for the production and storage of large quantities of hyperpolarized {sup 129}Xe for use in various applications.

  9. Relaxation rates of low-field gas-phase ^129Xe storage cells

    NASA Astrophysics Data System (ADS)

    Limes, Mark; Saam, Brian

    2010-10-01

    A study of longitudinal nuclear relaxation rates T1 of ^129Xe and Xe-N2 mixtures in a magnetic field of 3.8 mT is presented. In this regime, intrinsic spin relaxation is dominated by the intramolecular spin-rotation interaction due to persistent xenon dimers, a mechanism that can be quelled by introducing large amounts of N2 into the storage cell. Extrinsic spin relaxation is dominated by the wall-relaxation rate, which is the primary quantity of interest for the various low-field storage cells and coatings that we have tested. Previous group work has shown that extremely long gas-phase relaxation times T1 can be obtained, but only at large magnetic fields and low xenon densities. The current work is motivated by the practical benefits of retaining hyperpolarized ^129Xe for extended periods of time in a small magnetic field.

  10. Study of gas-fluidization dynamics with laser-polarized 129Xe.

    PubMed

    Wang, Ruopeng; Rosen, Matthew Scott; Candela, Donald; Mair, Ross William; Walsworth, Ronald Lee

    2005-02-01

    We report initial NMR studies of gas dynamics in a particle bed fluidized by laser-polarized xenon (129Xe) gas. We have made preliminary measurements of two important characteristics: gas exchange between the bubble and emulsion phases and the gas velocity distribution in the bed. We used T2* contrast to differentiate the bubble and emulsion phases by choosing solid particles with large magnetic susceptibility. Experimental tests demonstrated that this method was successful in eliminating 129Xe magnetization in the emulsion phase, which enabled us to observe the time dependence of the bubble magnetization. By employing the pulsed field gradient method, we also measured the gas velocity distribution within the bed. These results clearly show the onset of bubbling and can be used to deduce information about gas and particle motion in the fluidized bed. PMID:15833613

  11. Study of Gas-Fluidization Dynamics with Laser-Polarized 129Xe

    NASA Astrophysics Data System (ADS)

    Wang, R.; Rosen, M. S.; Candela, D.; Mair, R. W.; Walsworth, R. L.

    2004-07-01

    We report initial NMR studies of gas dynamics in a particle bed fluidized by laser-polarized xenon (129Xe) gas. We have made preliminary measurements of two important characteristics: gas exchange between the bubble and emulsion phases; and the gas velocity distribution in the bed. We used T2* contrast to differentiate the bubble and emulsion phases by choosing solid particles with large magnetic susceptibility, in order. Experimental tests demonstrated that this method was successful in eliminating 129Xe magnetization in the emulsion phase, which enabled us to observe the time-dependence of the bubble magnetization. By employing the pulsed field gradient method, we also measured the gas velocity distribution within the bed. These results clearly show the onset of bubbling and can be used to deduce information about gas and particle motion in the fluidized bed.

  12. Characterizing and modeling the efficiency limits in large-scale production of hyperpolarized 129Xe

    PubMed Central

    Freeman, M.S.; Emami, K.; Driehuys, B.

    2014-01-01

    The ability to produce liter volumes of highly spin-polarized 129Xe enables a wide range of investigations, most notably in the fields of materials science and biomedical MRI. However, for nearly all polarizers built to date, both peak 129Xe polarization and the rate at which it is produced fall far below those predicted by the standard model of Rb metal vapor, spin-exchange optical pumping (SEOP). In this work, we comprehensively characterized a high-volume, flow-through 129Xe polarizer using three different SEOP cells with internal volumes of 100, 200 and 300 cc and two types of optical sources: a broad-spectrum 111-W laser (FWHM = 1.92 nm) and a line-narrowed 71-W laser (FWHM = 0.39 nm). By measuring 129Xe polarization as a function of gas flow rate, we extracted peak polarization and polarization production rate across a wide range of laser absorption levels. Peak polarization for all cells consistently remained a factor of 2-3 times lower than predicted at all absorption levels. Moreover, although production rates increased with laser absorption, they did so much more slowly than predicted by the standard theoretical model and basic spin exchange efficiency arguments. Underperformance was most notable in the smallest optical cells. We propose that all these systematic deviations from theory can be explained by invoking the presence of paramagnetic Rb clusters within the vapor. Cluster formation within saturated alkali vapors is well established and their interaction with resonant laser light was recently shown to create plasma-like conditions. Such cluster systems cause both Rb and 129Xe depolarization, as well as excess photon scattering. These effects were incorporated into the SEOP model by assuming that clusters are activated in proportion to excited-state Rb number density and by further estimating physically reasonable values for the nanocluster-induced, velocity-averaged spin-destruction cross-section for Rb (<σcluster-Rbv> ≈4×10-7 cm3s-1), 129Xe

  13. Large Production of Hyperpolarized 129-Xe for MRI Applications

    NASA Astrophysics Data System (ADS)

    Ruset, Iulian; Hersman, F. W.; Distelbrink, Jan; Ketel, Stephen; Covrig, Silviu; Muradian, Iga; Sindile, Adrian

    2007-03-01

    Although 129-Xe was the first hyperpolarized gas to be used in MRI studies, the research community has focused on 3-He, mainly because of the larger quantities of hyperpolarized gas available. Xenon has advantages over helium, such as natural abundance, lower diffusion, and high solubility in blood. It presents a large frequency chemical shift when dissolved in blood, tissue, brain, or trapped in molecular cages. A new design of a high-flow low-pressure spin-exchange optical pumping Rb-Xe polarizer was recently demonstrated by our group. The concept of counterflowing the gas mixture against laser light and dividing the polarizing cell in three operational zones has resulted in an increase with over an order of magnitude in the output magnetization compared with previously reported polarizers. We were able to produce hyperpolarized xenon at 64% polarization for 0.3 liters/hour flow rate and 22% polarization at 6 liters/hour. We also demonstrated a new design of freezing and thawing hyperpolarized xenon with minimum losses. We will present the concept of the high-flow low-pressure counterflowing xenon polarizer, its performance, as well as new optical pumping laser technologies. We will discuss optimization plans for xenon polarizing systems based on experimental observed limitations and theoretical modeling.

  14. Double-Cell Geometry for 129Xe/3He Co-Magnetometry

    NASA Astrophysics Data System (ADS)

    Ohtomo, Yuichi; Ichikawa, Yuichi; Sato, Tomoya; Sakamoto, Yu; Kojima, Shuichiro; Suzuki, Takahiro; Shirai, Hazuki; Chikamori, Masatoshi; Hikota, Eri; Miyatake, Hirokazu; Nanao, Tsubasa; Suzuki, Kunifumi; Tsuchiya, Masato; Inoue, Takeshi; Furukawa, Takeshi; Yoshimi, Akihiro; Bidinosti, Christopher P.; Ino, Takashi; Ueno, Hideki; Matsuo, Yukari; Fukuyama, Takeshi; Asahi, Koichiro

    Comagnetometers play a key role in EDM experiments. They allow one to quantify, and subsequently correct for, any long-term drifts of the external magnetic field. In order to improve the performance of the 3He comagnetometer for our 129Xe EDM measurements, we have decided to incorporate a double-cell geometry which enables us to suppress a frequency shift due to contact interaction with polarized Rb atoms. In this study, the production and relaxation of 3He spin polarization in the double cell were studied. As a result, the followings were achieved: a polarization of 1.04(8)%, a longitudinal spin relaxation time of 10.1(5) h, and a transverse relaxation time of 2,340 s. With these improvements, concurrent operation of the 129Xe and 3He masers has been realized, and EDM measurement will be started in near future using a cell designed based on the results of this study.

  15. Free volume of poly(perfluorosulfonic acid)/SiO 2 composite proton exchange membranes by 129Xe NMR

    NASA Astrophysics Data System (ADS)

    Utiu, Lavinia; Filipoi, Carmen; Demco, Dan E.; Zhu, Xiaomin; Vinokur, Rostislav; Conradi, Oliver; Graichen, Andreas; Blümich, Bernhard; Möller, Martin

    2011-04-01

    Poly(perfluorosulfonic acid)/silica (PFSA/SiO2) composites were investigated by 129Xe NMR spectroscopy and relaxometry. 129Xe chemical shift extrapolated to zero pressure was used for calculation of average free volume hole size. This quantity reaches a maximum at 2 wt.% SiO2 that could be correlated to the performance of composites proton exchange membrane. 129Xe longitudinal magnetization relaxation revealed a bimodal distribution of the free volume that was explained by the presence of xenon atoms in the backbone and pendant-chain domains. Thus, the free volume is heterogeneous and depends on the content of SiO2. Implications of the free volume changes for the hydrogen crossover through PFSA/SiO2 membranes are also discussed.

  16. Oxygen-dependent hyperpolarized (129) Xe brain MR.

    PubMed

    Li, Haidong; Zhang, Zhiying; Zhong, Jianping; Ruan, Weiwei; Han, Yeqing; Sun, Xianping; Ye, Chaohui; Zhou, Xin

    2016-03-01

    Hyperpolarized (HP) (129) Xe MR offers unique advantages for brain functional imaging (fMRI) because of its extremely high sensitivity to different chemical environments and the total absence of background noise in biological tissues. However, its advancement and applications are currently plagued by issues of signal strength. Generally, xenon atoms found in the brain after inhalation are transferred from the lung via the bloodstream. The longitudinal relaxation time (T1 ) of HP (129) Xe is inversely proportional to the pulmonary oxygen concentration in the lung because oxygen molecules are paramagnetic. However, the T1 of (129) Xe is proportional to the pulmonary oxygen concentration in the blood, because the higher pulmonary oxygen concentration will result in a higher concentration of diamagnetic oxyhemoglobin. Accordingly, there should be an optimal pulmonary oxygen concentration for a given quantity of HP (129) Xe in the brain. In this study, the relationship between pulmonary oxygen concentration and HP (129) Xe signal in the brain was analyzed using a theoretical model and measured through in vivo experiments. The results from the theoretical model and experiments in rats are found to be in good agreement with each other. The optimal pulmonary oxygen concentration predicted by the theoretical model was 21%, and the in vivo experiments confirmed the presence of such an optimal ratio by reporting measurements between 25% and 35%. These findings are helpful for improving the (129) Xe signal in the brain and make the most of the limited spin polarization available for brain experiments. Copyright © 2016 John Wiley & Sons, Ltd. PMID:26915791

  17. Hyperpolarized 129Xe MRI: A Viable Functional Lung Imaging Modality?

    PubMed Central

    Patz, Samuel; Hersman, F. William; Muradian, Iga; Hrovat, Mirko I.; Ruset, Iulian C.; Ketel, Stephen; Jacobson, Francine; Topulos, George P.; Hatabu, Hiroto; Butler, James P.

    2008-01-01

    The majority of researchers investigating hyperpolarized gas MRI as a candidate functional lung imaging modality have used 3He as their imaging agent of choice rather than 129Xe. This preference has been predominantly due to, 3He providing stronger signals due to higher levels of polarization and higher gyromagnetic ratio, as well as its being easily available to more researchers due to availability of polarizers (USA) or ease of gas transport (Europe). Most researchers agree, however, that hyperpolarized 129Xe will ultimately emerge as the imaging agent of choice due to its unlimited supply in nature and its falling cost. Our recent polarizer technology delivers vast improvements in hyperpolarized 129Xe output. Using this polarizer, we have demonstrated the unique property of xenon to measure alveolar surface area noninvasively. In this article, we describe our human protocols and their safety, and our results for the measurement of the partial pressure of pulmonary oxygen (pO2) by observation of 129Xe signal decay. We note that the measurement of pO2 by observation of 129Xe signal decay is more complex than that for 3He because of an additional signal loss mechanism due to interphase diffusion of 129Xe from alveolar gas spaces to septal tissue. This results in measurements of an equivalent pO2 that accounts for both traditional T1 decay from pO2 and that from interphase diffusion. We also provide an update on new technological advancements that form the foundation for an improved compact design polarizer as well as improvements that provide another order-of-magnitude scale-up in xenon polarizer output. PMID:17890035

  18. Investigation of a 129Xe magnetometer for the Neutron Electric Dipole Moment Experiment at TRIUMF

    NASA Astrophysics Data System (ADS)

    Lang, Michael; Nedm At Triumf Collaboration

    2016-03-01

    A non-zero neutron electric dipole moment (nEDM) would signify a previously unknown source of CP (or T) violation. New sources of CP violation are believed to be required to explain the baryon asymmetry of the universe. Employing a newly developed high-density UCN source, an experiment at TRIUMF aims to measure the nEDM to the level of 10-27 e . cm in its initial phase. Precession frequency differences for UCN stored in a bottle subject to parallel and anti-parallel E and B fields signify a permanent nEDM. Magnetic field instability and inhomogeneity, as well as field changes resulting from leakage currents (correlated with E fields) are the dominant systematic effects in nEDM measurements. To address this, passive and active magnetic shielding are in development along with a dual species (129Xe and 199Hg) atomic comagnetometer. Simultaneously introducing both atomic species into the UCN cell, the comagnetometer can mitigate false EDMs. 199Hg precession will be detected by Faraday rotation spectroscopy, and 129Xe precession will measured via two-photon excitation and emission. The present comagnetometer progress will be discussed, with focus on polarized 129Xe production and delivery. Work supported by the Natural Sciences and Engineering Research Council of Canada.

  19. Molecular hydrogen and catalytic combustion in the production of hyperpolarized 83Kr and 129Xe MRI contrast agents

    NASA Astrophysics Data System (ADS)

    Rogers, Nicola J.; Hill-Casey, Fraser; Stupic, Karl F.; Six, Joseph S.; Lesbats, Clémentine; Rigby, Sean P.; Fraissard, Jacques; Pavlovskaya, Galina E.; Meersmann, Thomas

    2016-03-01

    Hyperpolarized (hp) 83Kr is a promising MRI contrast agent for the diagnosis of pulmonary diseases affecting the surface of the respiratory zone. However, the distinct physical properties of 83Kr that enable unique MRI contrast also complicate the production of hp 83Kr. This work presents a previously unexplored approach in the generation of hp 83Kr that can likewise be used for the production of hp 129Xe. Molecular nitrogen, typically used as buffer gas in spin-exchange optical pumping (SEOP), was replaced by molecular hydrogen without penalty for the achievable hyperpolarization. In this particular study, the highest obtained nuclear spin polarizations were P = 29% for 83Kr and P = 63% for 129Xe. The results were reproduced over many SEOP cycles despite the laser-induced on-resonance formation of rubidium hydride (RbH). Following SEOP, the H2 was reactively removed via catalytic combustion without measurable losses in hyperpolarized spin state of either 83Kr or 129Xe. Highly spin-polarized 83Kr can now be purified for the first time, to our knowledge, to provide high signal intensity for the advancement of in vivo hp 83Kr MRI. More generally, a chemical reaction appears as a viable alternative to the cryogenic separation process, the primary purification method of hp 129Xe for the past 2 1/2 decades. The inherent simplicity of the combustion process will facilitate hp 129Xe production and should allow for on-demand continuous flow of purified and highly spin-polarized 129Xe.

  20. Molecular hydrogen and catalytic combustion in the production of hyperpolarized 83Kr and 129Xe MRI contrast agents.

    PubMed

    Rogers, Nicola J; Hill-Casey, Fraser; Stupic, Karl F; Six, Joseph S; Lesbats, Clémentine; Rigby, Sean P; Fraissard, Jacques; Pavlovskaya, Galina E; Meersmann, Thomas

    2016-03-22

    Hyperpolarized (hp) (83)Kr is a promising MRI contrast agent for the diagnosis of pulmonary diseases affecting the surface of the respiratory zone. However, the distinct physical properties of (83)Kr that enable unique MRI contrast also complicate the production of hp (83)Kr. This work presents a previously unexplored approach in the generation of hp (83)Kr that can likewise be used for the production of hp (129)Xe. Molecular nitrogen, typically used as buffer gas in spin-exchange optical pumping (SEOP), was replaced by molecular hydrogen without penalty for the achievable hyperpolarization. In this particular study, the highest obtained nuclear spin polarizations were P =29% for(83)Kr and P= 63% for (129)Xe. The results were reproduced over many SEOP cycles despite the laser-induced on-resonance formation of rubidium hydride (RbH). Following SEOP, the H2 was reactively removed via catalytic combustion without measurable losses in hyperpolarized spin state of either (83)Kr or (129)Xe. Highly spin-polarized (83)Kr can now be purified for the first time, to our knowledge, to provide high signal intensity for the advancement of in vivo hp (83)Kr MRI. More generally, a chemical reaction appears as a viable alternative to the cryogenic separation process, the primary purification method of hp(129)Xe for the past 2 1/2 decades. The inherent simplicity of the combustion process will facilitate hp (129)Xe production and should allow for on-demand continuous flow of purified and highly spin-polarized (129)Xe. PMID:26961001

  1. Targeted Molecular Imaging of Cancer Cells Using MS2-Based (129)Xe NMR.

    PubMed

    Jeong, Keunhong; Netirojjanakul, Chawita; Munch, Henrik K; Sun, Jinny; Finbloom, Joel A; Wemmer, David E; Pines, Alexander; Francis, Matthew B

    2016-08-17

    We have synthesized targeted, selective, and highly sensitive (129)Xe NMR nanoscale biosensors using a spherical MS2 viral capsid, Cryptophane A molecules, and DNA aptamers. The biosensors showed strong binding specificity toward targeted lymphoma cells (Ramos line). Hyperpolarized (129)Xe NMR signal contrast and hyper-CEST (129)Xe MRI image contrast indicated its promise as highly sensitive hyperpolarized (129)Xe NMR nanoscale biosensor for future applications in cancer detection in vivo. PMID:27454679

  2. Cryptophane-Folate Biosensor for 129Xe NMR

    PubMed Central

    2015-01-01

    Folate-conjugated cryptophane was developed for targeting cryptophane to membrane-bound folate receptors that are overexpressed in many human cancers. The cryptophane biosensor was synthesized in 20 nonlinear steps, which included functionalization with folate recognition moiety, solubilizing peptide, and Cy3 fluorophore. Hyperpolarized 129Xe NMR studies confirmed xenon binding to the folate-conjugated cryptophane. Cellular internalization of biosensor was monitored by confocal laser scanning microscopy and quantified by flow cytometry. Competitive blocking studies confirmed cryptophane endocytosis through a folate receptor-mediated pathway. Flow cytometry revealed 10-fold higher cellular internalization in KB cancer cells overexpressing folate receptors compared to HT-1080 cells with normal folate receptor expression. The biosensor was determined to be nontoxic in HT-1080 and KB cells by MTT assay at low micromolar concentrations typically used for hyperpolarized 129Xe NMR experiments. PMID:25438187

  3. Combustion resistance of the 129Xe hyperpolarized nuclear spin state.

    PubMed

    Stupic, Karl F; Six, Joseph S; Olsen, Michael D; Pavlovskaya, Galina E; Meersmann, Thomas

    2013-01-01

    Using a methane-xenon mixture for spin exchange optical pumping, MRI of combustion was enabled. The (129)Xe hyperpolarized nuclear spin state was found to sufficiently survive the complete passage through the harsh environment of the reaction zone. A velocity profile (V(z)(z)) of a flame was recorded to demonstrate the feasibility of MRI velocimetry of transport processes in combustors. PMID:23165418

  4. XeNA: An automated ‘open-source’ 129Xe hyperpolarizer for clinical use

    PubMed Central

    Nikolaou, Panayiotis; Coffey, Aaron M.; Walkup, Laura L.; Gust, Brogan M.; Whiting, Nicholas; Newton, Hayley; Muradyan, Iga; Dabaghyan, Mikayel; Ranta, Kaili; Moroz, Gregory D.; Rosen, Matthew S.; Patz, Samuel; Barlow, Michael J.; Chekmenev, Eduard Y.; Goodson, Boyd M.

    2014-01-01

    Here we provide a full report on the construction, components, and capabilities of our consortium’s “open-source” large-scale (~1 L/hr) 129Xe hyperpolarizer for clinical, pre-clinical, and materials NMR/MRI (Nikolaou et al., Proc. Natl. Acad. Sci. USA, 110, 14150 (2013)). The ‘hyperpolarizer’ is automated and built mostly of off-the-shelf components; moreover, it is designed to be cost-effective and installed in both research laboratories and clinical settings with materials costing less than $125,000. The device runs in the xenon-rich regime (up to 1800 Torr Xe in 0.5 L) in either stopped-flow or single-batch mode—making cryo-collection of the hyperpolarized gas unnecessary for many applications. In-cell 129Xe nuclear spin polarization values of ~30-90% have been measured for Xe loadings of ~300-1600 Torr. Typical 129Xe polarization build-up and T1 relaxation time constants were ~8.5 min and ~1.9 hr respectively under our SEOP conditions; such ratios, combined with near-unity Rb electron spin polarizations enabled by the high resonant laser power (up to ~200 W), permits such high PXe values to be achieved despite the high in-cell Xe densities. Importantly, most of the polarization is maintained during efficient HP gas transfer to other containers, and ultra-long 129Xe relaxation times (up to nearly 6 hr) were observed in Tedlar bags following transport to a clinical 3 T scanner for MR spectroscopy and imaging as a prelude to in vivo experiments. The device has received FDA IND approval for a clinical study of COPD subjects. The primary focus of this paper is on the technical / engineering development of the polarizer, with the explicit goals of facilitating the adaptation of design features and operative modes into other laboratories, and of spurring the further advancement of HP-gas MR applications in biomedicine. PMID:24631715

  5. XeNA: an automated 'open-source' (129)Xe hyperpolarizer for clinical use.

    PubMed

    Nikolaou, Panayiotis; Coffey, Aaron M; Walkup, Laura L; Gust, Brogan M; Whiting, Nicholas; Newton, Hayley; Muradyan, Iga; Dabaghyan, Mikayel; Ranta, Kaili; Moroz, Gregory D; Rosen, Matthew S; Patz, Samuel; Barlow, Michael J; Chekmenev, Eduard Y; Goodson, Boyd M

    2014-06-01

    Here we provide a full report on the construction, components, and capabilities of our consortium's "open-source" large-scale (~1L/h) (129)Xe hyperpolarizer for clinical, pre-clinical, and materials NMR/MRI (Nikolaou et al., Proc. Natl. Acad. Sci. USA, 110, 14150 (2013)). The 'hyperpolarizer' is automated and built mostly of off-the-shelf components; moreover, it is designed to be cost-effective and installed in both research laboratories and clinical settings with materials costing less than $125,000. The device runs in the xenon-rich regime (up to 1800Torr Xe in 0.5L) in either stopped-flow or single-batch mode-making cryo-collection of the hyperpolarized gas unnecessary for many applications. In-cell (129)Xe nuclear spin polarization values of ~30%-90% have been measured for Xe loadings of ~300-1600Torr. Typical (129)Xe polarization build-up and T1 relaxation time constants were ~8.5min and ~1.9h respectively under our spin-exchange optical pumping conditions; such ratios, combined with near-unity Rb electron spin polarizations enabled by the high resonant laser power (up to ~200W), permit such high PXe values to be achieved despite the high in-cell Xe densities. Importantly, most of the polarization is maintained during efficient HP gas transfer to other containers, and ultra-long (129)Xe relaxation times (up to nearly 6h) were observed in Tedlar bags following transport to a clinical 3T scanner for MR spectroscopy and imaging as a prelude to in vivo experiments. The device has received FDA IND approval for a clinical study of chronic obstructive pulmonary disease subjects. The primary focus of this paper is on the technical/engineering development of the polarizer, with the explicit goals of facilitating the adaptation of design features and operative modes into other laboratories, and of spurring the further advancement of HP-gas MR applications in biomedicine. PMID:24631715

  6. Chemical shift of hyperpolarized 129Xe dissolved in liquid nitrogen

    NASA Astrophysics Data System (ADS)

    Patton, B.; Kuzma, N. N.; Happer, W.

    2002-01-01

    We report NMR measurements of hyperpolarized xenon dissolved in liquid nitrogen. The dependence of the 129Xe frequency shift on liquid nitrogen temperature was measured along the nitrogen saturated vapor curve from 77 to 93 K. Plotted as a function of the liquid nitrogen density, the chemical shift of xenon is very well described by a simple proportionality relation, with a slope of 0.2135(15) ppm/amagat. The relationship between the chemical shift and the longitudinal spin relaxation is considered in terms of the spin-rotation interaction, and estimates of Xe relaxation time in liquid nitrogen are discussed.

  7. Progress of the 129Xe EDM search using active feedback nuclear spin maser

    NASA Astrophysics Data System (ADS)

    Sato, Tomoya; Ichikawa, Yuichi; Ohtomo, Yuichi; Sakamoto, Yu; Kojima, Shuichiro; Funayama, Chikako; Suzuki, Takahiro; Chikamori, Masatoshi; Hikota, Eri; Tsuchiya, Masato; Furukawa, Takeshi; Yoshimi, Akihiro; Bidinosti, Christopher; Ino, Takashi; Ueno, Hideki; Matsuo, Yukari; Fukuyama, Takeshi; Asahi, Koichiro

    2014-09-01

    A permanent electric dipole moment (EDM) of a particle is an extremely sensitive probe for physics beyond the Standard Model. The objective of the present study is to search for the 129Xe EDM at a level of 10-28 ecm, beyond the current upper limit. In this experiment, an active-feedback nuclear spin maser is employed to achieve a precision measurement. Systematic instability sets a limit on the precision in our study. Co-magnetometry using 3He spin maser was incorporated into the maser system to eliminate the frequency drift caused by magnetic field fluctuations. Moreover, a double-cell geometry with linearly polarized laser was introduced to reduce frequency drifts arising from contact interactions with polarized Rb atoms. Having integrated these improvements, the 3He/129Xe dual spin maser was successfully operated. In the presentation, recent progress will be reported, including an analysis of spin maser frequencies, a study of electrode designs, and an estimation of possible systematic uncertainties.

  8. Search for a permanent electric dipole moment using liquid 129Xe

    SciTech Connect

    PROFESSOR MICHAEL ROMALIS

    2008-11-24

    Search for an electric dipole moment is one of the best motivated low-energy approaches for investigating physics beyond the Standard Model. Our experimental effort is focused on improving the limit on EDM in liquid 129Xe to put constraints on nuclear CP-violating interactions. High nuclear spin density and high electrical breakdown strength make 129Xe a promising medium for EDM searches. At the time the project started, the transverse nuclear spin relaxation time T2 of 129Xe was unknown. We made measurements of T2 using NMR spin-echo techniques and found that it is exceeds 1300 sec, the longest relaxation time ever measured in a liquid [1]. We also began to investigate non-linear dipolar interaction effects in a high-density spin-polarized liquid Xe. In the second iteration of the experiment we setup a high-Tc SQUID system in magnetic shields and performed detailed studies of Xe spin precession. We developed a model for non-linear dipolar interactions and found that for one set of conditions non-linear interactions can delay spin dephasing due to magnetic field gradients, while for another set of conditions they can lead to exponential amplification of the spin precession signals [2]. Our experimental data were in good quantitative agreement with predictions of the model. We also developed a series of numerical simulations to understand various imperfections in the system and made detailed experimental measurements to confirm these numerical predictions [3]. We demonstrated that non-linear interactions can amplify small precession signals and achieved an amplification factor of 10 [4]. This general phenomenon can be used in other precision measurements with non-linear interactions. We also explored practical applications of the liquid Xe system that we developed. We demonstrated that by mixing Xe with organic liquids, such as cyclopentane, one can enhance the proton spin polarization by a factor of 106 [5]. We have used this technique to perform the first

  9. (129)Xe NMR Relaxation-Based Macromolecular Sensing.

    PubMed

    Gomes, Muller D; Dao, Phuong; Jeong, Keunhong; Slack, Clancy C; Vassiliou, Christophoros C; Finbloom, Joel A; Francis, Matthew B; Wemmer, David E; Pines, Alexander

    2016-08-10

    We report a (129)Xe NMR relaxation-based sensing approach that exploits changes in the bulk xenon relaxation rate induced by slowed tumbling of a cryptophane-based sensor upon target binding. The amplification afforded by detection of the bulk dissolved xenon allows sensitive detection of targets. The sensor comprises a xenon-binding cryptophane cage, a target interaction element, and a metal chelating agent. Xenon associated with the target-bound cryptophane cage is rapidly relaxed and then detected after exchange with the bulk. Here we show that large macromolecular targets increase the rotational correlation time of xenon, increasing its relaxation rate. Upon binding of a biotin-containing sensor to avidin at 1.5 μM concentration, the free xenon T2 is reduced by a factor of 4. PMID:27472048

  10. Optically polarized {sup 129}Xe NMR investigation of carbon nanotubes

    SciTech Connect

    Clewett, Catherine F. M.; Morgan, Steven W.; Saam, Brian; Pietrass, Tanja

    2008-12-15

    We demonstrate the utility of optically polarized {sup 129}Xe NMR in a convection cell for measuring the surface properties of materials. In particular, we show adsorption of xenon gas on oxidatively purified single- and multiwalled carbon nanotubes. The interaction between xenon and multiwalled nanotubes produced by chemical vapor deposition was stronger than that of single- or multiwalled nanotubes produced by carbon arc discharge. Xenon was observed in gas, liquid, and adsorbed phases. The large polarization and moderate pressures of xenon ({approx}0.2 MPa) allowed resolution of multiple lines in both the gas and condensed phases of xenon in contact with carbon nanotubes. Xe gas exchanges with physisorbed xenon in two different environments. Xe adsorbs preferentially on defects, but if the number of defects is not sufficient, it will also adsorb on surface and interstitial sites. Penetration of Xe in the tube interior was not observed.

  11. Development of an antibody-based, modular biosensor for 129Xe NMR molecular imaging of cells at nanomolar concentrations.

    PubMed

    Rose, Honor M; Witte, Christopher; Rossella, Federica; Klippel, Stefan; Freund, Christian; Schröder, Leif

    2014-08-12

    Magnetic resonance imaging (MRI) is seriously limited when aiming for visualization of targeted contrast agents. Images are reconstructed from the weak diamagnetic properties of the sample and require an abundant molecule like water as the reporter. Micromolar to millimolar concentrations of conventional contrast agents are needed to generate image contrast, thus excluding many molecular markers as potential targets. To address this limitation, we developed and characterized a functional xenon NMR biosensor that can identify a specific cell surface marker by targeted (129)Xe MRI. Cells expressing the cell surface protein CD14 can be spatially distinguished from control cells with incorporation of as little as 20 nM of the xenon MRI readout unit, cryptophane-A. Cryptophane-A serves as a chemical host for hyperpolarized nuclei and facilitates the sensitivity enhancement achieved by xenon MRI. Although this paper describes the application of a CD14-specific biosensor, the construct has been designed in a versatile, modular fashion. This allows for quick and easy adaptation of the biosensor to any cell surface target for which there is a specific antibody. In addition, the modular design facilitates the creation of a multifunctional probe that incorporates readout modules for different detection methods, such as fluorescence, to complement the primary MRI readout. This modular antibody-based approach not only offers a practical technique with which to screen targets, but one which can be readily applied as the xenon MRI field moves closer to molecular imaging applications in vivo. PMID:25071165

  12. Development of an antibody-based, modular biosensor for 129Xe NMR molecular imaging of cells at nanomolar concentrations

    PubMed Central

    Rose, Honor M.; Witte, Christopher; Rossella, Federica; Klippel, Stefan; Freund, Christian; Schröder, Leif

    2014-01-01

    Magnetic resonance imaging (MRI) is seriously limited when aiming for visualization of targeted contrast agents. Images are reconstructed from the weak diamagnetic properties of the sample and require an abundant molecule like water as the reporter. Micromolar to millimolar concentrations of conventional contrast agents are needed to generate image contrast, thus excluding many molecular markers as potential targets. To address this limitation, we developed and characterized a functional xenon NMR biosensor that can identify a specific cell surface marker by targeted 129Xe MRI. Cells expressing the cell surface protein CD14 can be spatially distinguished from control cells with incorporation of as little as 20 nM of the xenon MRI readout unit, cryptophane-A. Cryptophane-A serves as a chemical host for hyperpolarized nuclei and facilitates the sensitivity enhancement achieved by xenon MRI. Although this paper describes the application of a CD14-specific biosensor, the construct has been designed in a versatile, modular fashion. This allows for quick and easy adaptation of the biosensor to any cell surface target for which there is a specific antibody. In addition, the modular design facilitates the creation of a multifunctional probe that incorporates readout modules for different detection methods, such as fluorescence, to complement the primary MRI readout. This modular antibody-based approach not only offers a practical technique with which to screen targets, but one which can be readily applied as the xenon MRI field moves closer to molecular imaging applications in vivo. PMID:25071165

  13. Measuring surface-area-to-volume ratios in soft porous materials using laser-polarized xenon interphase exchange nuclear magnetic resonance

    NASA Technical Reports Server (NTRS)

    Butler, J. P.; Mair, R. W.; Hoffmann, D.; Hrovat, M. I.; Rogers, R. A.; Topulos, G. P.; Walsworth, R. L.; Patz, S.

    2002-01-01

    We demonstrate a minimally invasive nuclear magnetic resonance (NMR) technique that enables determination of the surface-area-to-volume ratio (S/V) of soft porous materials from measurements of the diffusive exchange of laser-polarized 129Xe between gas in the pore space and 129Xe dissolved in the solid phase. We apply this NMR technique to porous polymer samples and find approximate agreement with destructive stereological measurements of S/V obtained with optical confocal microscopy. Potential applications of laser-polarized xenon interphase exchange NMR include measurements of in vivo lung function in humans and characterization of gas chromatography columns.

  14. 3D MRI of impaired hyperpolarized 129Xe uptake in a rat model of pulmonary fibrosis.

    PubMed

    Cleveland, Zackary I; Virgincar, Rohan S; Qi, Yi; Robertson, Scott H; Degan, Simone; Driehuys, Bastiaan

    2014-12-01

    A variety of pulmonary pathologies, in particular interstitial lung diseases, are characterized by thickening of the pulmonary blood-gas barrier, and this thickening results in reduced gas exchange. Such diffusive impairment is challenging to quantify spatially, because the distributions of the metabolically relevant gases (CO2 and O2) cannot be detected directly within the lungs. Hyperpolarized (HP) (129)Xe is a promising surrogate for these metabolic gases, because MR spectroscopy and imaging allow gaseous alveolar (129)Xe to be detected separately from (129)Xe dissolved in the red blood cells (RBCs) and the adjacent tissues, which comprise blood plasma and lung interstitium. Because (129)Xe reaches the RBCs by diffusing across the same barrier tissues (blood plasma and interstitium) as O2, barrier thickening will delay (129)Xe transit and, thus, reduce RBC-specific (129)Xe MR signal. Here we have exploited these properties to generate 3D, MR images of (129)Xe uptake by the RBCs in two groups of rats. In the experimental group, unilateral fibrotic injury was generated prior to imaging by instilling bleomycin into one lung. In the control group, a unilateral sham instillation of saline was performed. Uptake of (129)Xe by the RBCs, quantified as the fraction of RBC signal relative to total dissolved (129)Xe signal, was significantly reduced (P = 0.03) in the injured lungs of bleomycin-treated animals. In contrast, no significant difference (P = 0.56) was observed between the saline-treated and untreated lungs of control animals. Together, these results indicate that 3D MRI of HP (129)Xe dissolved in the pulmonary tissues can provide useful biomarkers of impaired diffusive gas exchange resulting from fibrotic thickening. PMID:24816478

  15. Detection and characterization of xenon-binding sites in proteins by 129Xe NMR spectroscopy.

    PubMed

    Rubin, Seth M; Lee, Seok-Yong; Ruiz, E Janette; Pines, Alexander; Wemmer, David E

    2002-09-13

    Xenon-binding sites in proteins have led to a number of applications of xenon in biochemical and structural studies. Here we further develop the utility of 129Xe NMR in characterizing specific xenon-protein interactions. The sensitivity of the 129Xe chemical shift to its local environment and the intense signals attainable by optical pumping make xenon a useful NMR reporter of its own interactions with proteins. A method for detecting specific xenon-binding interactions by analysis of 129Xe chemical shift data is illustrated using the maltose binding protein (MBP) from Escherichia coli as an example. The crystal structure of MBP in the presence of 8atm of xenon confirms the binding site determined from NMR data. Changes in the structure of the xenon-binding cavity upon the binding of maltose by the protein can account for the sensitivity of the 129Xe chemical shift to MBP conformation. 129Xe NMR data for xenon in solution with a number of cavity containing phage T4 lysozyme mutants show that xenon can report on cavity structure. In particular, a correlation exists between cavity size and the binding-induced 129Xe chemical shift. Further applications of 129Xe NMR to biochemical assays, including the screening of proteins for xenon binding for crystallography are considered. PMID:12217701

  16. High-spin structures in the 129Xe nucleus

    NASA Astrophysics Data System (ADS)

    Huang, Y.; Xiao, Z. G.; Zhu, S. J.; Qi, C.; Xu, Q.; Cheng, W. J.; Li, H. J.; Lyu, L. M.; Wang, R. S.; Yan, W. H.; Yi, H.; Zhang, Y.; Chen, Q. M.; He, C. Y.; Hu, S. P.; Li, C. B.; Li, H. W.; Luo, P. W.; Wu, X. G.; Wu, Y. H.; Zheng, Y.; Zhong, J.

    2016-06-01

    High-spin states in the 129Xe nucleus are studied with the reaction 124Sn(9Be,4 n ) at a beam energy of 36 MeV. The level scheme is extended significantly. For the positive-parity band, the α =+1 /2 and the α =-1 /2 signature components are combined to form a complete band structure based on the 3 /2+ state with spin and parity up to 21 /2+ . For the negative-parity band based on the 11 /2- state, the α =+1 /2 signature component is newly established and both the α =+1 /2 and the α =-1 /2 signature components also form a complete band structure up to the 35 /2- state. The positive- and negative-parity bands are proposed to originate from ν d3 /23 /2+[402 ] and ν h11 /211 /2-[505 ] Nilsson configurations, respectively. A backbending is observed in the negative-parity band, which originates from the alignments of two h11 /2 protons according to crank shell model calculations. Based on the total Routhian surface and quasiparticle triaxial rotor model calculations, the negative-parity band is interpreted as a triaxially deformed shape with γ ≈-30∘ , while the positive-parity band is associated with γ softness, in accordance with previous studies. In the high-spin states, three decoupled bands and one oblate band with γ ≈-60∘ are newly identified. The systematics and other characteristics of these bands are discussed.

  17. Diffusion of hyperpolarized 129Xe in the lung: a simplified model of 129Xe septal uptake and experimental results

    NASA Astrophysics Data System (ADS)

    Patz, Samuel; Muradyan, Iga; Hrovat, Mirko I.; Dabaghyan, Mikayel; Washko, George R.; Hatabu, Hiroto; Butler, James P.

    2011-01-01

    We used hyperpolarized 129Xe NMR to measure pulmonary alveolar surface area per unit gas volume SA/Vgas, alveolar septal thickness h and capillary transit time τ, three critical determinants of the lung's primary role as a gas exchange organ. An analytical solution for a simplified diffusion model is described, together with a modification of the xenon transfer contrast imaging technique utilizing 90° radio-frequency pulses applied to the dissolved phase, rather than traditional 180° pulses. With this approach, three-dimensional (3D) maps of SA/Vgas were obtained. We measured global SA/Vgas, h and τ in four normal subjects, two subjects with mild interstitial lung disease (ILD) and two subjects with mild chronic obstructive pulmonary disease (COPD). In normals, SA/Vgas decreased with increasing lung volume from ~320 to 80 cm-1 both h~13 μm and τ~1.5 s were relatively constant. For the two ILD subjects, h was, respectively, 36 and 97% larger than normal, quantifying an increased gas/blood tissue barrier; SA/Vgas and τ were normal. The two COPD subjects had SA/Vgas values ~25% that of normals, quantifying septal surface loss in emphysema; h and τ were normal. These are the first noninvasive, non-radiation-based, quantitative measurements of h and τ in patients with pulmonary disease.

  18. Magnetic resonance imaging of convection in laser-polarized xenon

    NASA Technical Reports Server (NTRS)

    Mair, R. W.; Tseng, C. H.; Wong, G. P.; Cory, D. G.; Walsworth, R. L.

    2000-01-01

    We demonstrate nuclear magnetic resonance (NMR) imaging of the flow and diffusion of laser-polarized xenon (129Xe) gas undergoing convection above evaporating laser-polarized liquid xenon. The large xenon NMR signal provided by the laser-polarization technique allows more rapid imaging than one can achieve with thermally polarized gas-liquid systems, permitting shorter time-scale events such as rapid gas flow and gas-liquid dynamics to be observed. Two-dimensional velocity-encoded imaging shows convective gas flow above the evaporating liquid xenon, and also permits the measurement of enhanced gas diffusion near regions of large velocity variation.

  19. Frequency characteristics of nuclear spin oscillator with an artificial feedback toward search for 129Xe atomic electric dipole moment

    NASA Astrophysics Data System (ADS)

    Inoue, Takeshi; Furukawa, Takeshi; Yoshimi, Akihiro; Nanao, Tsubasa; Chikamori, Masatoshi; Suzuki, Kunifumi; Hayashi, Hironori; Miyatake, Hirokazu; Ichikawa, Yuichi; Tsuchiya, Masato; Hatakeyama, Naoto; Kagami, Sota; Uchida, Makoto; Ueno, Hideki; Matsuo, Yukari; Fukuyama, Takeshi; Asahi, Koichiro

    2016-06-01

    A 129Xe nuclear spin oscillator with an artificial feedback was constructed, and detailed studies were conducted on its performance, focusing on the frequency stability. As a result, the major sources of drift of the precession frequency in the present spin oscillator setup were identified to be drifts of a solenoid current and an environmental magnetic field. By introducing stabilization systems for the current and the environmental field, which yielded improvements by one order of magnitude on the solenoid current and by a factor of three on the environmental field, a frequency precision of 7.9 nHz was obtained for a one-shot measurement of 3 × 104 s duration. We found, however, that the Allan deviation leveled off at around 30 μHz, indicating a strong need for the precision monitor of the experimental conditions represented by magnetometry. The frequency stability of the spin oscillator is discussed in relation to an experimental search for an electric dipole moment of the 129Xe atom.

  20. Rotaxane-mediated suppression and activation of cucurbit[6]uril for molecular detection by (129)Xe hyperCEST NMR.

    PubMed

    Finbloom, Joel A; Slack, Clancy C; Bruns, Carson J; Jeong, Keunhong; Wemmer, David E; Pines, Alexander; Francis, Matthew B

    2016-02-21

    We report a method for blocking interactions between (129)Xe and cucurbit[6]uril (CB6) until activation by a specific chemical event. We synthesized a CB6-rotaxane that allowed no (129)Xe interaction with the CB6 macrocycle component until a cleavage event released the CB6, which then produced a (129)Xe@CB6 NMR signal. This contrast-upon-activation (129)Xe NMR platform allows for modular synthesis and can be expanded to applications in detection and disease imaging. PMID:26795714

  1. Performance check of cell with newly designed electrode for 129Xe EDM measurement

    NASA Astrophysics Data System (ADS)

    Sakamoto, Yu; Bidinosti, Christopher; Ichikawa, Yuichi; Sato, Tomoya; Ohtomo, Yuichi; Kojima, Shuichiro; Funayama, Chikako; Suzuki, Takahiro; Tsuchiya, Masato; Furukawa, Takeshi; Yoshimi, Akihiro; Ino, Takashi; Ueno, Hideki; Matuo, Yukari; Fukuyama, Takeshi; Asahi, Koichiro

    2014-09-01

    A permanent electric dipole moment (EDM) can be detected as a difference between the spin precession frequencies measured with an electric field applied parallel and antiparallel to a magnetic field. We aim to make a measurement of the 129Xe EDM at a level of d ~10-28 e cm by using a nuclear spin maser. The amplitude of the maser signal is proportional to the nuclear spin polarization. The polarization of 3He that acts as a co-magnetometer, is sensitive to the interactions with the electrodes used to generate the electric field. Previously, we used a transparent electrode made of ITO (Indium Tin Oxide) to allow transmission linearly polarized laser light into the cell. However, 3He polarization in a cell with such electrodes was measured to be ~0.1%, which is ten times smaller than no electrodes. In order to solve the problem, we adopted an electrode made from a mesh of Molybdenum. The geometry also reduces the contact area between 3He gas and the electrode. We measured 3He polarization at a cell with the mesh electrode by means of adiabatic fast passage NMR.

  2. Probing zeolite internal structures using very low temperature {sup 129}Xe NMR

    SciTech Connect

    Labouriau, A.; Crawford, S.N.; Earl, W.L.; Pietrass, T.; Weber, W.A.; Panjabi, G.; Gates, B.C.

    1998-08-01

    In recent years, probing pore structure with {sup 129}Xe NMR has received a bad reputation. This is due to the fact that the method is more complex than was originally suggested so the data is somewhat difficult to interpret. The authors find that the use of a wide temperature range (40--350 K) allows them to interpret {sup 129}Xe chemical shifts in terms of van der Waals attraction between the xenon atom and oxygen in zeolite walls. Using rather simple models from the literature, they can extract useful pore size information as well as the van der Waals potential energy.

  3. A new ^3He-^129Xe Co-magnetometer using a Ramsey measurement sequence and Rb-K magnetometer for spin detection

    NASA Astrophysics Data System (ADS)

    Kabcenell, Aaron; Kominis, Iannis; Romalis, Michael

    2012-06-01

    Noble gas co-magnetometers have been used for many precision measurements, but their sensitivity is still very far from fundamental limits. We are exploring a new approach for operation of a ^3He-^129Xe co-magnetometer that uses a sensitive Rb-K magnetometer as a spin detector. By placing the noble gas atoms inside the magnetometer cell we can increase their magnetic signal using the Fermi-contact interaction, representing a gain of nearly 500 for ^129Xe, and achieve nearly quantum-noise limited detection of nuclear spins. In order to take advantage of the long coherence times of ^3He and^129Xe, the precession measurement is based on the Ramsey method of separated oscillatory fields and will be performed in an alkali-metal-free volume. The gas is then transported to the spin detector using techniques developed for remote NMR detection. The sensitivity of this approach is estimated to be on the order of 10-13 Hz/day^1/2, making it several orders of magnitude more sensitive than the best existing co-magnetometers. We are currently performing tests of the Ramsey measurement method and the sensitivity of the spin detector.

  4. A New Search for the Atomic EDM of 129Xe at FRM-II (Munich Research Reactor)

    NASA Astrophysics Data System (ADS)

    Singh, Jaideep; Fierlinger, Peter; Kraegeloh, Eva; Kuchler, Florian; Lins, Tobias; Marino, Mike; Meinel, Jonas; Neissen, Benjamin; Stuiber, Stefan; Burghoff, Martin; Fan, Isaac; Kilian, Wolfgang; Knappe-Grueneberg, Silvia; Schnabel, Allard; Seifert, Frank; Trahms, Lutz; Voigt, Jens; Chupp, Tim; Degenkolb, Skyler; Gong, Fei; Sachdeva, Natasha; Babcock, Earl

    2014-09-01

    Electric dipole moments (EDMs) arise due to the breaking of time-reversal or, equivalently, CP -symmetry. Although all searches have so far only set upper limits on EDMs, the motivation for more sensitive searches is stronger than ever. The present limit of 6 ×10-27 e * cm (95% CL) for the 129Xe EDM helps constrain CP -violating parameters within nuclei. A new effort at FRM-II incorporating a 3He comagnetometer can potentially improve this limit by over three orders of magnitude. The noble gas mixture is polarized by spin-exchange optical pumping and then transferred into a high-performance magnetically shielded room. A SQUID magnetometer array measures the precession frequencies in the presence of applied electric- & magnetic-fields. Recent test runs indicate that the experiment is capable of an EDM sensitivity of 10-28 e * cm in one day.

  5. A New Search for the Atomic EDM of 129 Xe at FRM-II (Munich Research Reactor)

    NASA Astrophysics Data System (ADS)

    Kuchler, Florian; Fierlinger, Peter; Kraegeloh, Eva; Lins, Tobias; Marino, Mike; Meinel, Jonas; Niessen, Benjamin; Stuiber, Stefan; Burghoff, Martin; Fan, Isaac; Kilian, Wolfgang; Knappe-Grueneberg, Silvia; Schnabel, Allard; Seifert, Frank; Trahms, Lutz; Voigt, Jens; Chupp, Tim; Degenkolb, Skyler; Gong, Fei; Sachdeva, Natasha; Babcock, Earl; Singh, Jaideep

    2015-04-01

    Electric dipole moments (EDMs) arise due to the breaking of time-reversal or, equivalently, CP-symmetry. Although all searches have so far only set upper limits on EDMs, the motivation for more sensitive searches is stronger than ever. The present limit of 6 × 10-27 e*cm (95 % CL) for the 129 Xe EDM helps constrain CP-violating parameters within nuclei. A new effort at FRM-II incorporating a 3 He comagnetometer can potentially improve this limit by over three orders of magnitude. The noble gas mixture is polarized by spin-exchange optical pumping and then transferred into a high-performance magnetically shielded room. A SQUID magnetometer array measures the precession frequencies in the presence of applied electric- and magnetic-fields. Recent test runs indicate that the experiment is capable of an EDM sensitivity of 10-28 e*cm in one day.

  6. Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications☆

    PubMed Central

    Hughes-Riley, Theodore; Six, Joseph S.; Lilburn, David M.L.; Stupic, Karl F.; Dorkes, Alan C.; Shaw, Dominick E.; Pavlovskaya, Galina E.; Meersmann, Thomas

    2013-01-01

    As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp 129Xe or hp 83Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp 129Xe handling, while 83Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The 83Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of 129Xe in corresponding mixtures. The experimental setup also facilitated 129Xe T1 relaxation measurements as a function of O2 concentration within excised lungs. PMID:24135800

  7. Cryogenics free production of hyperpolarized 129Xe and 83Kr for biomedical MRI applications.

    PubMed

    Hughes-Riley, Theodore; Six, Joseph S; Lilburn, David M L; Stupic, Karl F; Dorkes, Alan C; Shaw, Dominick E; Pavlovskaya, Galina E; Meersmann, Thomas

    2013-12-01

    As an alternative to cryogenic gas handling, hyperpolarized (hp) gas mixtures were extracted directly from the spin exchange optical pumping (SEOP) process through expansion followed by compression to ambient pressure for biomedical MRI applications. The omission of cryogenic gas separation generally requires the usage of high xenon or krypton concentrations at low SEOP gas pressures to generate hp (129)Xe or hp (83)Kr with sufficient MR signal intensity for imaging applications. Two different extraction schemes for the hp gasses were explored with focus on the preservation of the nuclear spin polarization. It was found that an extraction scheme based on an inflatable, pressure controlled balloon is sufficient for hp (129)Xe handling, while (83)Kr can efficiently be extracted through a single cycle piston pump. The extraction methods were tested for ex vivo MRI applications with excised rat lungs. Precise mixing of the hp gases with oxygen, which may be of interest for potential in vivo applications, was accomplished during the extraction process using a piston pump. The (83)Kr bulk gas phase T1 relaxation in the mixtures containing more than approximately 1% O2 was found to be slower than that of (129)Xe in corresponding mixtures. The experimental setup also facilitated (129)Xe T1 relaxation measurements as a function of O2 concentration within excised lungs. PMID:24135800

  8. 3D MR Imaging of Impaired Hyperpolarized 129Xe Uptake in a Rat Model of Pulmonary Fibrosis

    PubMed Central

    Cleveland, Zackary I.; Virgincar, Rohan, S.; Qi, Yi; Robertson, Scott H.; Degan, Simone; Driehuys, Bastiaan

    2014-01-01

    A variety of pulmonary pathologies, in particular interstitial lung diseases, are characterized by thickening of the pulmonary blood-gas barrier tissues, and this thickening results in reduced gas exchange. Such diffusive impairment is challenging to quantify spatially, because the distributions of the metabolically relevant gases (CO2 and O2) cannot be detected directly within the lungs. Hyperpolarized (HP) 129Xe is a promising surrogate for these metabolic gases, because MR spectroscopy and imaging allow gaseous alveolar 129Xe to be detected separately from 129Xe dissolved in the red blood cells (RBCs) and in the adjacent barrier tissues (blood plasma and lung interstitium). Further, because 129Xe reaches the RBCs by diffusing across the same barrier tissues as O2barrier thickening will delay 129Xe transit and, thus, reduce RBC-specific 129Xe MR signal. Here we exploited these properties to generate 3D, MR images of 129Xe uptake by the RBCs in two groups of rats. In the experimental group, unilateral fibrotic injury was generated prior to imaging by instilling Bleomycin into one lung. In the control group, a unilateral sham instillation of saline was performed. Uptake of 129Xe by the RBCs, quantified as the fraction of RBC signal relative to total dissolved 129Xe signal, was significantly reduced (P = 0.03) in the injured lungs of Bleomycin-treated animals. In contrast, no significant difference (P=0.56) was observed between the saline-treated and untreated lungs of control animals. Together, these results indicate that 3D MRI of HP 129Xe dissolved in the pulmonary tissues can provide useful biomarkers of impaired diffusive gas exchange resulting from fibrotic thickening. PMID:24816478

  9. Biomedical Investigations with Laser-Polarized Noble Gas Magnetic Resonance

    NASA Technical Reports Server (NTRS)

    Walsworth, Ronald L.

    2003-01-01

    We pursued advanced technology development of laser-polarized noble gas nuclear magnetic resonance (NMR) as a novel biomedical imaging tool for ground-based and eventually space-based application. This new multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI)-e.g., of lung ventilation-as well as studies of tissue perfusion. In addition, laser-polarized noble gases (3He and 129Xe) do not require a large magnetic field for sensitive detection, opening the door to practical MRI at very low magnetic fields with an open, lightweight, and low-power device. We pursued two technology development specific aims: (1) development of low-field (less than 0.01 T) noble gas MRI of humans; and (2) development of functional MRI of the lung using laser-polarized noble gas and related techniques.

  10. Bacterial spore detection and analysis using hyperpolarized 129Xe chemical exchange saturation transfer (Hyper-CEST) NMR

    PubMed Central

    Bai, Yubin; Wang, Yanfei; Goulian, Mark; Driks, Adam

    2014-01-01

    Previously, we reported hyperpolarized 129Xe chemical exchange saturation transfer (Hyper-CEST) NMR techniques for the ultrasensitive (i.e., 1 picomolar) detection of xenon host molecules known as cryptophane. Here, we demonstrate a more general role for Hyper-CEST NMR as a spectroscopic method for probing nanoporous structures, without the requirement for cryptophane or engineered xenon-binding sites. Hyper-CEST 129Xe NMR spectroscopy was employed to detect Bacillus anthracis and Bacillus subtilis spores in solution, and interrogate the layers that comprise their structures. 129Xe-spore samples were selectively irradiated with radiofrequency pulses; the depolarized 129Xe returned to aqueous solution and depleted the 129Xe-water signal, providing measurable contrast. Removal of the outermost spore layers in B. anthracis and B. subtilis (the exosporium and coat, respectively) enhanced 129Xe exchange with the spore interior. Notably, the spores were invisible to hyperpolarized 129Xe NMR direct detection methods, highlighting the lack of high-affinity xenon-binding sites, and the potential for extending Hyper-CEST NMR structural analysis to other biological and synthetic nanoporous structures. PMID:25089181

  11. Distinguishing multiple chemotaxis Y protein conformations with laser-polarized 129Xe NMR

    SciTech Connect

    Lowery, Thomas J.; Doucleff, Michealeen; Ruiz, E. Janette; Rubin, Seth M.; Pines, Alexander; Wemmer, David E.

    2005-02-01

    The chemical shift of the {sup 129}Xe NMR signal has been shown to be extremely sensitive to the local environment around the atom and has been used to follow processes such as ligand binding by bacterial periplasmic binding proteins (Rubin et al. 2000; Lowery et al. 2004). Here we show that the {sup 129}Xe shift can sense more subtle changes: magnesium binding, BeF{sub 3}{sup -} activation, and peptide binding by the E. coli chemotaxis Y protein. {sup 1}H-{sup 15}N correlation spectroscopy and x-ray crystallography were used to identify two xenon-binding cavities in CheY that are primarily responsible for the shift changes. One site is near the active site, and the other is near the peptide binding site.

  12. A 3 He-129 Xe co-magnetometer with 87 Rb magnetometry

    NASA Astrophysics Data System (ADS)

    Limes, Mark; Sheng, Dong; Romalis, Mike

    2016-05-01

    We report progress on a 3 He-129 Xe co-magnetometer detected with a 87 Rb magnetometer. The noble-gas co-magnetometer is insensitive to any long-term bias field drifts, but the presence of hot Rb can cause instability in the ratio of 3 He-129 Xe precession frequencies. We use a sequence of Rb π pulses to suppress the instability due to Rb-noble gas interactions by a factor of 104 along all three spatial axes. For detection, our 87 Rb magnetometer operates using single-axis 87 Rb π pulses with σ+ /σ- pumping-this technique decouples the 87 Rb magnetometer from bias fields, and allows for SERF operation. We are presently investigating systematic effects due to combinations of several imperfections, such as longitudinal noble gas polarization, imperfect 87 Rb π pulses, and 87 Rb pump light shifts. Thus far, our 87 Rb magnetometer has a sensitivity of 40 fT/√{Hz}, and our 3 He-129 Xe co-magnetometer has achieved a single-shot precession frequency ratio error of 20 nHz and a long-term bias drift of 8 nHz at 7 h. We are developing the co-magnetometer for use as an NMR gyro, and to search for possible spin-gravity interactions. Supported by DARPA and NSF.

  13. Frequency characteristics of a nuclear spin maser for the search for the electric dipole moment of 129Xe atom

    NASA Astrophysics Data System (ADS)

    Inoue, T.; Tsuchiya, M.; Furukawa, T.; Hayashi, H.; Nanao, T.; Yoshimi, A.; Uchida, M.; Matsuo, Y.; Asahi, K.

    2011-01-01

    Frequency characteristics of a 129Xe nuclear spin maser was studied, which is under development at Tokyo Institute of Technology for the search for a permanent electric dipole moment in diamagnetic 129Xe atom. Drifts in the solenoid current and cell temperature were found to be the most influential factors on the maser frequency. From correlation coefficient analysis, there seem to exist other origins of frequency fluctuation, such as phase drifts in the maser oscillation. In order to improve the stability of the maser frequency, the intensity of the pumping laser required to fully polarize 129Xe nuclei was evaluated. Construction of a polarization assessment system for 129Xe gas cells and development of a new scheme of current stabilization are also remarked.

  14. Multidimensional Mapping of Spin-Exchange Optical Pumping in Clinical-Scale Batch-Mode 129Xe Hyperpolarizers

    PubMed Central

    2015-01-01

    We present a systematic, multiparameter study of Rb/129Xe spin-exchange optical pumping (SEOP) in the regimes of high xenon pressure and photon flux using a 3D-printed, clinical-scale stopped-flow hyperpolarizer. In situ NMR detection was used to study the dynamics of 129Xe polarization as a function of SEOP-cell operating temperature, photon flux, and xenon partial pressure to maximize 129Xe polarization (PXe). PXe values of 95 ± 9%, 73 ± 4%, 60 ± 2%, 41 ± 1%, and 31 ± 1% at 275, 515, 1000, 1500, and 2000 Torr Xe partial pressure were achieved. These PXe polarization values were separately validated by ejecting the hyperpolarized 129Xe gas and performing low-field MRI at 47.5 mT. It is shown that PXe in this high-pressure regime can be increased beyond already record levels with higher photon flux and better SEOP thermal management, as well as optimization of the polarization dynamics, pointing the way to further improvements in hyperpolarized 129Xe production efficiency. PMID:24731261

  15. Multidimensional mapping of spin-exchange optical pumping in clinical-scale batch-mode 129Xe hyperpolarizers.

    PubMed

    Nikolaou, Panayiotis; Coffey, Aaron M; Ranta, Kaili; Walkup, Laura L; Gust, Brogan M; Barlow, Michael J; Rosen, Matthew S; Goodson, Boyd M; Chekmenev, Eduard Y

    2014-05-01

    We present a systematic, multiparameter study of Rb/(129)Xe spin-exchange optical pumping (SEOP) in the regimes of high xenon pressure and photon flux using a 3D-printed, clinical-scale stopped-flow hyperpolarizer. In situ NMR detection was used to study the dynamics of (129)Xe polarization as a function of SEOP-cell operating temperature, photon flux, and xenon partial pressure to maximize (129)Xe polarization (PXe). PXe values of 95 ± 9%, 73 ± 4%, 60 ± 2%, 41 ± 1%, and 31 ± 1% at 275, 515, 1000, 1500, and 2000 Torr Xe partial pressure were achieved. These PXe polarization values were separately validated by ejecting the hyperpolarized (129)Xe gas and performing low-field MRI at 47.5 mT. It is shown that PXe in this high-pressure regime can be increased beyond already record levels with higher photon flux and better SEOP thermal management, as well as optimization of the polarization dynamics, pointing the way to further improvements in hyperpolarized (129)Xe production efficiency. PMID:24731261

  16. Nondisruptive Dissolution of Hyperpolarized (129)Xe into Viscous Aqueous and Organic Liquid Crystalline Environments.

    PubMed

    Truxal, Ashley E; Slack, Clancy C; Gomes, Muller D; Vassiliou, Christophoros C; Wemmer, David E; Pines, Alexander

    2016-04-01

    Studies of hyperpolarized xenon-129 (hp-(129)Xe) in media such as liquid crystals and cell suspensions are in demand for applications ranging from biomedical imaging to materials engineering but have been hindered by the inability to bubble Xe through the desired media as a result of viscosity or perturbations caused by bubbles. Herein a device is reported that can be reliably used to dissolve hp-(129)Xe into viscous aqueous and organic samples without bubbling. This method is robust, requires small sample volumes (<60 μL), is compatible with existing NMR hardware, and is made from readily available materials. Experiments show that Xe can be introduced into viscous and aligned media without disrupting molecular order. We detected dissolved xenon in an aqueous liquid crystal that is disrupted by the shear forces of bubbling, and we observed liquid-crystal phase transitions in (MBBA). This tool allows an entirely new class of samples to be investigated by hyperpolarized-gas NMR spectroscopy. PMID:26954536

  17. A Molecular Imaging Approach to Mercury Sensing Based on Hyperpolarized (129)Xe Molecular Clamp Probe.

    PubMed

    Guo, Qianni; Zeng, Qingbin; Jiang, Weiping; Zhang, Xiaoxiao; Luo, Qing; Zhang, Xu; Bouchard, Louis-S; Liu, Maili; Zhou, Xin

    2016-03-14

    Mercury pollution, in the form of mercury ions (Hg(2+)), is a major health and environmental hazard. Commonly used sensors are invasive and limited to point measurements. Fluorescence-based sensors do not provide depth resolution needed to image spatial distributions. Herein we report a novel sensor capable of yielding spatial distributions by MRI using hyperpolarized (129)Xe. A molecular clamp probe was developed consisting of dipyrrolylquinoxaline (DPQ) derivatives and twocryptophane-A cages. The DPQ derivatives act as cation receptors whereas cryptophane-A acts as a suitable host molecule for xenon. When the DPQ moiety interacts with mercury ions, the molecular clamp closes on the ion. Due to overlap of the electron clouds of the two cryptophane-A cages, the shielding effect on the encapsulated Xe becomes important. This leads to an upfield change of the chemical shift of the encapsulated Xe. This sensor exhibits good selectivity and sensitivity toward the mercury ion. This mercury-activated hyperpolarized (129)Xe-based chemosensor is a new concept method for monitoring Hg(2+) ion distributions by MRI. PMID:26792102

  18. Investigation of DOTA-Metal Chelation Effects on the Chemical Shift of (129) Xe.

    PubMed

    Jeong, Keunhong; Slack, Clancy C; Vassiliou, Christophoros C; Dao, Phuong; Gomes, Muller D; Kennedy, Daniel J; Truxal, Ashley E; Sperling, Lindsay J; Francis, Matthew B; Wemmer, David E; Pines, Alexander

    2015-12-01

    Recent work has shown that xenon chemical shifts in cryptophane-cage sensors are affected when tethered chelators bind to metals. Here, we explore the xenon shifts in response to a wide range of metal ions binding to diastereomeric forms of 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) linked to cryptophane-A. The shifts induced by the binding of Ca(2+) , Cu(2+) , Ce(3+) , Zn(2+) , Cd(2+) , Ni(2+) , Co(2+) , Cr(2+) , Fe(3+) , and Hg(2+) are distinct. In addition, the different responses of the diastereomers for the same metal ion indicate that shifts are affected by partial folding with a correlation between the expected coordination number of the metal in the DOTA complex and the chemical shift of (129) Xe. These sensors may be used to detect and quantify many important metal ions, and a better understanding of the basis for the induced shifts could enhance future designs. PMID:26376768

  19. Temperature response of 129Xe depolarization transfer and its application for ultra-sensitive NMR detection

    SciTech Connect

    Schroeder, Leif; Schroder, Leif; Meldrum, Tyler; Smith, Monica; Lowery, Thomas J.; Wemmer, David E.; Pines, Alexander

    2008-03-20

    Temporary trapping of atomic xenon in functionalized cryptophane cages makes the high sensitivity of hyperpolarized (hp) 129Xe available for highly specific NMR detection of biomolecules like proteins in solution. Here, we study the signal transfer onto a reservoir of unbound hp xenon by gating the residence time of the nuclei in the cage through the temperature-dependent exchange rate. Temperature changes were detectable immediately as an altered reservoir signal and yielded a sensitivity of 0.6 K. The temperature response is adjustable with lower concentrations of caged xenon providing more sensitivity at higher temperatures and allows ultra-sensitive detection of such molecular cages at 310 K. Functionalized cryptophane could be detected at concentrations as low as 10nM which corresponds to a 4000-fold sensitivity enhancement compared to conventional detection. This sensitivity makes hp-NMR capable of detecting such constructs in concentrations far belowthe detection limit by UV-visible light absorbance.

  20. Experimental search for EDM in diamagnetic atom 129Xe using active nuclear spin maser

    NASA Astrophysics Data System (ADS)

    Ichikawa, Yuichi; Sato, Tomoya; Ohtomo, Yuichi; Sakamoto, Yu; Kojima, Shuichiro; Funayama, Chikako; Hirao, Chika; Suzuki, Takahiro; Chikamori, Masatoshi; Hikota, Eri; Miyatake, Hirokazu; Nanao, Tsubasa; Suzuki, Kunifumi; Tsuchiya, Masato; Inoue, Takeshi; Furukawa, Takeshi; Yoshimi, Akihiko; Bidinosti, Christopher; Ino, Takashi; Ueno, Hideki; Matsuo, Yukari; Fukuyama, Takeshi; Asahi, Koichiro

    2014-09-01

    A permanent electric dipole moment (EDM) which directly means T-violation attracts much attention, because an unknown CP-violating phase which is necessary to understand the present matter-dominated Universe is expected to be probed by EDM. The present study aims at measuring the EDM in the diamagnetic atom 129Xe to a size of 10-28 ecm, stepping into a domain below the present upper limit by one order of magnitude. In the present experiment, we employ an active nuclear spin maser which has characteristics of the optical detection of the spin precession and the artificial production of the feedback field to sustain the spin precession over a long measurement duration. For the magnetometry in the measurement, a comagnetometer using 3He is incorporated to the spin maser system. In this presentation, the current status of our experiment will be given.

  1. Multifragmentation in intermediate energy {sup 129}Xe-induced heavy-ion reactions

    SciTech Connect

    Tso, Kin

    1996-05-01

    The {sup 129}Xe-induced reactions on {sup nat}Cu, {sup 89}Y, {sup 165}Ho, and {sup 197}Au at bombarding energies of E/A = 40 & 60 MeV have been studied theoretically and experimentally in order to establish the underlying mechanism of multifragmentation at intermediate energy heavy-Ion collisions. Nuclear disks formed in central heavy-ion collisions, as simulated by means of Boltzmann-like kinetic equations, break up into several fragments due to a new kind of Rayleigh-like surface instability. A sheet of liquid, stable in the limit of non-interacting surfaces, is shown to become unstable due to surface-surface interactions. The onset of this instability is determined analytically. A thin bubble behaves like a sheet and is susceptible to the surface instability through the crispation mode. The Coulomb effects associated with the depletion of charges in the central cavity of nuclear bubbles are investigated. The onset of Coulomb instability is demonstrated for perturbations of the radial mode. Experimental intermediate-mass-fragment multiplicity distributions for the {sup 129}Xe-induced reactions are shown to be binomial at each transverse energy. From these distributions, independent of the specific target, an elementary binary decay probability p can be extracted that has a thermal dependence. Thus it is inferred that multifragmentation is reducible to a combination of nearly independent emission processes. If sequential decay is assumed, the increase of p with transverse energy implies a contraction of the emission time scale. The sensitivity of p to the lower Z threshold in the definition of intermediate-mass-fragments points to a physical Poisson simulations of the particle multiplicities show that the weak auto-correlation between the fragment multiplicity and the transverse energy does not distort a Poisson distribution into a binomial distribution. The effect of device efficiency on the experimental results has also been studied.

  2. INSTRUMENTS AND METHODS OF INVESTIGATION: On experiments in search of the T-odd electric dipole moment of atomic 129Xe

    NASA Astrophysics Data System (ADS)

    Sobel'man, Igor I.; Sorokin, Vadim N.

    2005-09-01

    A new method is proposed for the search of the electric dipole moment of atomic 129Xe arising from time reversal symmetry violation. We consider the basic features of the experiment to measure the electric field of T-odd EDMs of spin-polarized 129Xe atoms with the aid of a Stark electrometer involving Rydberg atoms.

  3. {sup 129}Xe magic-angle spinning spectra of xenon in zeolite NaA direct observation of mixed clusters of co-adsorbed species.

    SciTech Connect

    Jameson, A. K.; Jameson, C. J.; de Dios, A. C.; Oldfield, E.; Gerald, R. E., II; Turner, G. L.; Chemical Engineering; Loyola Univ.; Univ. of Illinois at Chicago; Univ. of Illinois; Spectral Data Services, Inc.

    1995-01-01

    We present the first demonstration that the individual {sup 129}Xe resonances corresponding to Xe{sub n} (n = 1-8) clusters inside the {alpha}-cages of zeolite NaA can be narrowed under magic-angle spinning (MAS). Under these high-resolution conditions we also observe upon addition of Kr the individual peaks corresponding to mixed clusters, Xe{sub n}Kr{sub m}, inside the a-cages, which will allow the first direct determination of the distribution of co-adsorbates in a microporous solid. Under MAS the chemical shifts of the Xe{sub n} clusters are shown to be highly sensitive to 'disorder' in the zeolite and provides new, quantitative information about the presence of {alpha}-cages of several types.

  4. Nuclear magnetic resonance studies of xenon clusters in zeolite NaA

    SciTech Connect

    Jameson, C. J.; Jameson, A. K.; Gerald, R. E., II; de Dios, A. C.; Chemical Engineering; Univ. of Illinois at Chicago; Loyola Univ.

    1992-02-01

    We have observed the equilibrium distribution of Xe atoms trapped in the alpha cages of zeolite NaA at 300 and at 360 K for low to high xenon loadings. The experimental distributions obtained by nuclear magnetic resonance (NMR) spectroscopy differ from two previously proposed statistical distributions. The experimental deviations from these statistical models can be explained by the attractive Xe-Xe interactions which favor clustering at low to medium loading, and the higher energies associated with the overcrowded cage disfavoring clusters of eight Xe atoms at high loadings. The temperature dependence of the {sup 129}Xe NMR chemical shift of each cluster has been measured in the range 188-421 K, except that for Xe{sub 8}, which was determined only up to 300 K. The observed shifts and their temperature dependence are interpreted by using the results of ab initio calculations of the intermolecular shielding function in the {sup 39}Ar system as a model for the {sup 129}Xe system.

  5. Performance assessment of a new laser system for efficient spin exchange optical pumping in a spin maser measurement of 129Xe EDM

    NASA Astrophysics Data System (ADS)

    Funayama, C.; Furukawa, T.; Sato, T.; Ichikawa, Y.; Ohtomo, Y.; Sakamoto, Y.; Kojima, S.; Suzuki, T.; Hirao, C.; Chikamori, M.; Hikota, E.; Tsuchiya, M.; Yoshimi, A.; Bidinosti, C. P.; Ino, T.; Ueno, H.; Matsuo, Y.; Fukuyama, T.; Asahi, K.

    2015-11-01

    We demonstrate spin-exchange optical pumping of 129Xe atoms with our newly made laser system. The new laser system was prepared to provide higher laser power required for the stable operation of spin maser oscillations in the 129Xe EDM experiment. We studied the optimum cell temperature and pumping laser power to improve the degree of 129Xe spin polarization. The best performance was achieved at the cell temperature of 100 ∘C with the presently available laser power of 1 W. The results show that a more intense laser is required for further improvement of the spin polarization at higher cell temperatures in our experiment.

  6. Limit on Lorentz-Invariance- and CPT-Violating Neutron Spin Interactions Using a 3He-129Xe Comagnetometer

    NASA Astrophysics Data System (ADS)

    Allmendinger, F.; Schmidt, U.; Heil, W.; Karpuk, S.; Sobolev, Yu.; Tullney, K.

    2016-02-01

    We performed a search for a Lorentz-invariance- and CPT-violating coupling of the 3He and 129Xe nuclear spins to posited background fields. Our experimental approach is to measure the free precession of nuclear spin polarized 3He and 129Xe atoms using SQUIDs as detectors. As the laboratory reference frame rotates with respect to distant stars, we look for a sidereal modulation of the Larmor frequencies of the co-located spin samples. As a result we obtain an upper limit on the equatorial component of the background field b˜⊥n < 8.4 ṡ 10‑34 GeV (68% C.L.). This experiment is currently the most precise test of spin anisotropy due to the excellent long spin-coherence time.

  7. Polarization and hyperfine transitions of metastable ^{129}Xe in discharge cells

    NASA Astrophysics Data System (ADS)

    Xia, T.; Morgan, S. W.; Jau, Y.-Y.; Happer, W.

    2010-03-01

    The polarization and relaxation rates of metastable Xe129 atoms are measured with magnetic resonance spectroscopy, at both microwave frequencies, where ΔF=1 transitions are induced between the sublevels, and at radiofrequencies, corresponding to ΔF=0 transitions. The nuclear spin polarization of the resonant velocity group is measured to be 22±2%. The relaxation of metastable xenon atoms is dominated by depolarizing collisions with ground-state atoms, with lesser contributions from metastability exchange collisions.

  8. Understanding cage effects in imidazolium ionic liquids by 129Xe NMR: MD simulations and relativistic DFT calculations.

    PubMed

    Saielli, Giacomo; Bagno, Alessandro; Castiglione, Franca; Simonutti, Roberto; Mauri, Michele; Mele, Andrea

    2014-12-01

    (129)Xe NMR has been recently employed to probe the local structure of ionic liquids (ILs). However, no theoretical investigation has been yet reported addressing the problem of the dependence of the chemical shift of xenon on the cage structure of the IL. Therefore, we present here a study of the chemical shift of (129)Xe in two ionic liquids, [bmim][Cl] and [bmim][PF6], by a combination of classical MD simulations and relativistic DFT calculations of the xenon shielding constant. The bulk structure of the two ILs is investigated by means of the radial distribution functions, paying special attention to the local structure, volume, and charge distribution of the cage surrounding the xenon atom. Relativistic DFT calculations, based on the ZORA formalism, on clusters extracted from the trajectory files of the two systems, yield an average relative chemical shift in good agreement with the experimental data. Our results demonstrate the importance of the cage volume and the average charge surrounding the xenon nucleus in the IL cage as the factors determining the effective shielding. PMID:25394282

  9. Search for Spin-Dependent Short-Range Interaction with an 3He/129Xe Clock Comparison Experiment

    NASA Astrophysics Data System (ADS)

    Tullney, Kathlynne; Heil, Werner; Karpuk, Sergei; Sobolev, Yuri; Allmendinger, Fabian; Schmidt, Ulrich

    2016-02-01

    We performed an experiment to search for a new spin-dependent P- and T-violating nucleon-nucleon interaction σ→ ṡr̂ which is mediated by light pseudoscalar bosons such as axions or axionlike particles. This interaction causes a shift Δν in the precession frequency of nuclear spin polarized gases in the presence of an unpolarized mass. In order to measure this frequency shift a 3He/129Xe comagnetometer was used which is based on the detection of free precession of 3He and 129Xe nuclear spins using SQUIDs as detectors. For the upper limit of Δνsp we obtained 7.1nHz. With this value, an upper limit of the scalar-pseudoscalar coupling of the axion to the spin of a bound neutron could be deduced within the axion mass window. For axion masses between 2 and 500μeV, the laboratory upper bounds were improved by up to 4 orders of magnitude.

  10. Magnetic Resonance Imaging (MRI)

    MedlinePlus

    ... How Can I Help a Friend Who Cuts? Magnetic Resonance Imaging (MRI) KidsHealth > For Teens > Magnetic Resonance Imaging (MRI) Print A A A Text Size What's ... Exam Safety Getting Your Results What Is MRI? Magnetic resonance imaging (MRI) is a type of safe, painless testing ...

  11. Nuclear Magnetic Resonance

    NASA Astrophysics Data System (ADS)

    Andrew, E. R.

    2009-06-01

    Author's preface; 1. Introduction; 2. Basic theory; 3. Experimental methods; 4. Measurement of nuclear properties and general physical applications; 5. Nuclear magnetic resonance in liquids and gases; 6. Nuclear magnetic resonance in non-metallic solids; 7. Nuclear magnetic resonance in metals; 8. Quadrupole effects; Appendices 1-6; Glossary of symbols; Bibliography and author index; Subject index.

  12. Relativistic effects in the intermolecular interaction-induced nuclear magnetic resonance parameters of xenon dimer.

    PubMed

    Hanni, Matti; Lantto, Perttu; Ilias, Miroslav; Jensen, Hans Jorgen Aagaard; Vaara, Juha

    2007-10-28

    Relativistic effects on the (129)Xe nuclear magnetic resonance shielding and (131)Xe nuclear quadrupole coupling (NQC) tensors are examined in the weakly bound Xe(2) system at different levels of theory including the relativistic four-component Dirac-Hartree-Fock (DHF) method. The intermolecular interaction-induced binary chemical shift delta, the anisotropy of the shielding tensor Deltasigma, and the NQC constant along the internuclear axis chi( parallel) are calculated as a function of the internuclear distance. DHF shielding calculations are carried out using gauge-including atomic orbitals. For comparison, the full leading-order one-electron Breit-Pauli perturbation theory (BPPT) is applied using a common gauge origin. Electron correlation effects are studied at the nonrelativistic (NR) coupled-cluster singles and doubles with perturbational triples [CCSD(T)] level of theory. The fully relativistic second-order Moller-Plesset many-body perturbation (DMP2) theory is used to examine the cross coupling between correlation and relativity on NQC. The same is investigated for delta and Deltasigma by BPPT with a density functional theory model. A semiquantitative agreement between the BPPT and DHF binary property curves is obtained for delta and Deltasigma in Xe(2). For these properties, the currently most complete theoretical description is obtained by a piecewise approximation where the uncorrelated relativistic DHF results obtained close to the basis-set limit are corrected, on the one hand, for NR correlation effects and, on the other hand, for the BPPT-based cross coupling of relativity and correlation. For chi( parallel), the fully relativistic DMP2 results obtain a correction for NR correlation effects beyond MP2. The computed temperature dependence of the second virial coefficient of the (129)Xe nuclear shielding is compared to experiment in Xe gas. Our best results, obtained with the piecewise approximation for the binary chemical shift combined with the

  13. DFT study of the NMR properties of xenon in covalent compounds and van der waals complexes-implications for the use of 129Xe as a molecular probe.

    PubMed

    Bagno, Alessandro; Saielli, Giacomo

    2003-04-01

    The NMR properties (chemical shift and spin-spin coupling constants) of (129)Xe in covalent compounds and weakly bound complexes have been investigated by DFT methods including relativistic effects. For covalent species, a good agreement between experimental and calculated results is achieved without scalar relativistic effects, but their inclusion (with a triple-zeta, double-polarization basis set) leads to some improvement in the quality of the correlation. The spin-orbit coupling term has a significant effect on the shielding constant, but makes a small contribution to the chemical shift. Coupling constants contain substantial contributions from the Fermi contact and paramagnetic spin-orbit terms; unlike light nuclei the spin-dipole term is also large, whereas the diamagnetic spin-orbit term is negligible. For van der Waals dimers, the dependence of the xenon chemical shift and anisotropy is calculated as a function of the distance. Small (<1 Hz) but non-negligible through-space coupling constants between (129)Xe and (13)C or (1)H are predicted. Much larger couplings, of the order of few Hz, are calculated between xenon and (17)O in a model silicate residue. PMID:12658645

  14. Projectile-like fragments from {sup 129}Xe+{sup nat}Cu reactions at E/A = 40 MeV

    SciTech Connect

    Russ, D.E.; Mignerey, A.C.; Garcia-Solis, E.J.

    1996-02-01

    The bombarding of heavy nuclei with energetic heavy projectiles has been one of the most important experimental tools for nuclear science. At low beam energies, (E/A) beam <10 MeV, the reactions appear to be dominated by mean field consideration. At higher beam energies, (E/A) beams > 100 MeV, these mean field effects are less important and nucleon-nucleon interactions dominate. Within the intermediate energy region, the situation is less clear because of both the mean field and nucleon-nucleon effects contribute. There is no consensus on the theoretical treatment of nuclear reaction in the intermediate energy regime and statistical, dynamical, and hybrid models have been used with limited success. Previous studies of {sup 136}Xe + {sup 209}Bi at E/A = 28 MeV carried out at Michigan State University (MSU) have been well described by a damped reaction mechanism. On the other hand, {sup 129}Xe + {sup nat}Cu at E/A = 50 MeV also at MSU has been compared with a hybrid model with reasonable success. In order to see a transition from a damped reaction mechanism to more fragmentation-like processes, an experiment was carried out at MSU using {sup 129}Xe beams at E/A = 30, 40, 50, and 60 MeV. The targets were Cu, Sc, and Au. The current study only looks at the projectile-like fragments (PLF) detected in the Maryland Forward Array (MFA).

  15. Development of techniques in magnetic resonance and structural studies of the prion protein

    SciTech Connect

    Bitter, Hans-Marcus L.

    2000-07-01

    Magnetic resonance is the most powerful analytical tool used by chemists today. Its applications range from determining structures of large biomolecules to imaging of human brains. Nevertheless, magnetic resonance remains a relatively young field, in which many techniques are currently being developed that have broad applications. In this dissertation, two new techniques are presented, one that enables the determination of torsion angles in solid-state peptides and proteins, and another that involves imaging of heterogenous materials at ultra-low magnetic fields. In addition, structural studies of the prion protein via solid-state NMR are described. More specifically, work is presented in which the dependence of chemical shifts on local molecular structure is used to predict chemical shift tensors in solid-state peptides with theoretical ab initio surfaces. These predictions are then used to determine the backbone dihedral angles in peptides. This method utilizes the theoretical chemicalshift tensors and experimentally determined chemical-shift anisotropies (CSAs) to predict the backbone and side chain torsion angles in alanine, leucine, and valine residues. Additionally, structural studies of prion protein fragments are described in which conformationally-dependent chemical-shift measurements were made to gain insight into the structural differences between the various conformational states of the prion protein. These studies are of biological and pathological interest since conformational changes in the prion protein are believed to cause prion diseases. Finally, an ultra-low field magnetic resonance imaging technique is described that enables imaging and characterization of heterogeneous and porous media. The notion of imaging gases at ultra-low fields would appear to be very difficult due to the prohibitively low polarization and spin densities as well as the low sensitivities of conventional Faraday coil detectors. However, Chapter 5 describes how gas imaging

  16. Hyperpolarized xenon magnetic resonance of the lung and the brain

    NASA Astrophysics Data System (ADS)

    Venkatesh, Arvind Krishnamachari

    2001-04-01

    Hyperpolarized noble gas Magnetic Resonance Imaging (MRI) is a new diagnostic modality that has been used successfully for lung imaging. Xenon is soluble in blood and inhaled xenon is transported to the brain via circulating blood. Xenon also accumulates in the lipid rich white matter of the brain. Hyperpolarized xenon can hence be used as a tissue- sensitive probe of brain function. The goals of this study were to identify the NMR resonances of xenon in the rat brain and evaluate the role of hyperpolarized xenon for brain MRI. We have developed systems to produce sufficient volumes of hyperpolarized xenon for in vivo brain experiments. The specialized instrumentation developed include an apparatus for optical pump-cell manufacture and high purity gas manifolds for filling cells. A hyperpolarized gas delivery system was designed to ventilate small animals with hyperpolarized xenon for transport to the brain. The T1 of xenon dissolved in blood indicates that the lifetime of xenon in the blood is sufficient for significant magnetization to be transferred to distal tissues. A variety of carrier agents for intravenous delivery of hyperpolarized xenon were tested for transport to distal tissues. Using our new gas delivery system, high SNR 129Xe images of rat lungs were obtained. Spectroscopy with hyperpolarized xenon indicated that xenon was transported from the lungs to the blood and tissues with intact magnetization. After preliminary studies that indicated the feasibility for in vivo rat brain studies, experiments were performed with adult rats and young rats with different stages of white matter development. Both in vivo and in vitro experiments showed the prominence of one peak from xenon in the rat brain, which was assigned to brain lipids. Cerebral brain perfusion was calculated from the wash-out of the hyperpolarized xenon signal in the brain. An increase in brain perfusion during maturation was observed. These experiments showed that hyperpolarized xenon MRI

  17. Hyperpolarized Xenon-129 Magnetic Resonance Imaging of Functional Lung Microstructure

    NASA Astrophysics Data System (ADS)

    Dregely, Isabel

    Hyperpolarized 129Xe (HXe) is a non-invasive contrast agent for lung magnetic resonance imaging (MRI), which upon inhalation follows the functional pathway of oxygen in the lung by dissolving into lung tissue structures and entering the blood stream. HXe MRI therefore provides unique opportunities for functional lung imaging of gas exchange which occurs from alveolar air spaces across the air-blood boundary into parenchymal tissue. However challenges in acquisition speed and signal-to-noise ratio have limited the development of a HXe imaging biomarker to diagnose lung disease. This thesis addresses these challenges by introducing parallel imaging to HXe MRI. Parallel imaging requires dedicated hardware. This work describes design, implementation, and characterization of a 32-channel phased-array chest receive coil with an integrated asymmetric birdcage transmit coil tuned to the HXe resonance on a 3 Tesla MRI system. Using the newly developed human chest coil, a functional HXe imaging method, multiple exchange time xenon magnetization transfer contrast (MXTC) is implemented. MXTC dynamically encodes HXe gas exchange into the image contrast. This permits two parameters to be derived regionally which are related to gas-exchange functionality by characterizing tissue-to-alveolar-volume ratio and alveolar wall thickness in the lung parenchyma. Initial results in healthy subjects demonstrate the sensitivity of MXTC by quantifying the subtle changes in lung microstructure in response to orientation and lung inflation. Our results in subjects with lung disease show that the MXTC-derived functional tissue density parameter exhibits excellent agreement with established imaging techniques. The newly developed dynamic parameter, which characterizes the alveolar wall, was elevated in subjects with lung disease, most likely indicating parenchymal inflammation. In light of these observations we believe that MXTC has potential as a biomarker for the regional quantification of 1

  18. Magnetic resonance annual, 1988

    SciTech Connect

    Kressel, H.Y.

    1987-01-01

    This book features reviews of high-resolution MRI of the knee, MRI of the normal and ischmeic hip, MRI of the heart, and temporomandibular joint imaging, as well as thorough discussion on artifacts in magnetic resonance imaging. Contributors consider the clinical applications of gadolinium-DTPA in magnetic resonance imaging and the clinical use of partial saturation and saturation recovery sequences. Timely reports assess the current status of rapid MRI and describe a new rapid gated cine MRI technique. Also included is an analysis of cerebrospinal fluid flow effects during MRI of the central nervous system.

  19. Magnetic resonance imaging

    SciTech Connect

    Stark, D.D.; Bradley, W.G. Jr.

    1988-01-01

    The authors present a review of magnetic resonance imaging. Many topics are explored from instrumentation, spectroscopy, blood flow and sodium imaging to detailed clinical applications such as the differential diagnosis of multiple sclerosis or adrenal adenoma. The emphasis throughout is on descriptions of normal multiplanar anatomy and pathology as displayed by MRI.

  20. Magnetic Resonance Annual, 1985

    SciTech Connect

    Kressel, H.Y.

    1985-01-01

    The inaugural volume of Magnetic Resonance Annual includes reviews of MRI of the posterior fossa, cerebral neoplasms, and the cardiovascular and genitourinary systems. A chapter on contrast materials outlines the mechanisms of paramagnetic contrast enhancement and highlights several promising contrast agents.

  1. Single spin magnetic resonance

    NASA Astrophysics Data System (ADS)

    Wrachtrup, Jörg; Finkler, Amit

    2016-08-01

    Different approaches have improved the sensitivity of either electron or nuclear magnetic resonance to the single spin level. For optical detection it has essentially become routine to observe a single electron spin or nuclear spin. Typically, the systems in use are carefully designed to allow for single spin detection and manipulation, and of those systems, diamond spin defects rank very high, being so robust that they can be addressed, read out and coherently controlled even under ambient conditions and in a versatile set of nanostructures. This renders them as a new type of sensor, which has been shown to detect single electron and nuclear spins among other quantities like force, pressure and temperature. Adapting pulse sequences from classic NMR and EPR, and combined with high resolution optical microscopy, proximity to the target sample and nanoscale size, the diamond sensors have the potential to constitute a new class of magnetic resonance detectors with single spin sensitivity. As diamond sensors can be operated under ambient conditions, they offer potential application across a multitude of disciplines. Here we review the different existing techniques for magnetic resonance, with a focus on diamond defect spin sensors, showing their potential as versatile sensors for ultra-sensitive magnetic resonance with nanoscale spatial resolution.

  2. Single spin magnetic resonance.

    PubMed

    Wrachtrup, Jörg; Finkler, Amit

    2016-08-01

    Different approaches have improved the sensitivity of either electron or nuclear magnetic resonance to the single spin level. For optical detection it has essentially become routine to observe a single electron spin or nuclear spin. Typically, the systems in use are carefully designed to allow for single spin detection and manipulation, and of those systems, diamond spin defects rank very high, being so robust that they can be addressed, read out and coherently controlled even under ambient conditions and in a versatile set of nanostructures. This renders them as a new type of sensor, which has been shown to detect single electron and nuclear spins among other quantities like force, pressure and temperature. Adapting pulse sequences from classic NMR and EPR, and combined with high resolution optical microscopy, proximity to the target sample and nanoscale size, the diamond sensors have the potential to constitute a new class of magnetic resonance detectors with single spin sensitivity. As diamond sensors can be operated under ambient conditions, they offer potential application across a multitude of disciplines. Here we review the different existing techniques for magnetic resonance, with a focus on diamond defect spin sensors, showing their potential as versatile sensors for ultra-sensitive magnetic resonance with nanoscale spatial resolution. PMID:27378060

  3. Functional Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Voos, Avery; Pelphrey, Kevin

    2013-01-01

    Functional magnetic resonance imaging (fMRI), with its excellent spatial resolution and ability to visualize networks of neuroanatomical structures involved in complex information processing, has become the dominant technique for the study of brain function and its development. The accessibility of in-vivo pediatric brain-imaging techniques…

  4. [Magnetic resonance, an introduction].

    PubMed

    Cabrera Rueda, D J; Fernández Herrerías, G

    2000-09-01

    What would you explain to a patient if he/she had to undergo a magnetic resonance imagery session? Do you know if a person wearing a pacemaker can undergo an MRI? These and many other questions are answered in the following article since magnetic resonance imagery is a very useful diagnostic medium; however, it is one which not everyone has been able to get to know and use. The authors shed light on this diagnostic technique for nurses starting with its physical foundations; since knowing these aids professionals to correctly plan our treatments and improves the attention provided to patients who undergo this test. The authors also list the specific components in this device, the possible biological effects, the detractions and some basic recommendations. PMID:11111673

  5. New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited)

    SciTech Connect

    Zhao, H. W.; Sun, L. T.; Zhang, X. Z.; Guo, X. H.; Zhao, H. Y.; Feng, Y. C.; Li, J. Y.; Ma, H. Y.; Ma, B. H.; Wang, H.; Li, X. X.; Xie, D. Z.; Lu, W.; Cao, Y.; Shang, Y.

    2010-02-15

    Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e {mu}A of {sup 129}Xe{sup 43+}, 22 e {mu}A of {sup 209}Bi{sup 41+}, and 1.5 e {mu}A of {sup 209}Bi{sup 50+}. To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e {mu}A of {sup 129}Xe{sup 27+} and 152 e {mu}A of {sup 129}Xe{sup 30+}, although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and {sup 129}Xe{sup 27+}, {sup 78}Kr{sup 19+}, {sup 209}Bi{sup 31+}, and {sup 58}Ni{sup 19+} beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of

  6. New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited).

    PubMed

    Zhao, H W; Sun, L T; Lu, W; Zhang, X Z; Guo, X H; Cao, Y; Zhao, H Y; Feng, Y C; Li, J Y; Ma, H Y; Shang, Y; Ma, B H; Wang, H; Li, X X; Xie, D Z

    2010-02-01

    Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e microA of (129)Xe(43+), 22 e microA of (209)Bi(41+), and 1.5 e microA of (209)Bi(50+). To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e microA of (129)Xe(27+) and 152 e microA of (129)Xe(30+), although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and (129)Xe(27+), (78)Kr(19+), (209)Bi(31+), and (58)Ni(19+) beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production

  7. Cavity- and waveguide-resonators in electron paramagnetic resonance, nuclear magnetic resonance, and magnetic resonance imaging.

    PubMed

    Webb, Andrew

    2014-11-01

    Cavity resonators are widely used in electron paramagnetic resonance, very high field magnetic resonance microimaging and also in high field human imaging. The basic principles and designs of different forms of cavity resonators including rectangular, cylindrical, re-entrant, cavity magnetrons, toroidal cavities and dielectric resonators are reviewed. Applications in EPR and MRI are summarized, and finally the topic of traveling wave MRI using the magnet bore as a waveguide is discussed. PMID:25456314

  8. Magnetic Resonance Facility (Fact Sheet)

    SciTech Connect

    Not Available

    2012-03-01

    This fact sheet provides information about Magnetic Resonance Facility capabilities and applications at NREL's National Bioenergy Center. Liquid and solid-state analysis capability for a variety of biomass, photovoltaic, and materials characterization applications across NREL. NREL scientists analyze solid and liquid samples on three nuclear magnetic resonance (NMR) spectrometers as well as an electron paramagnetic resonance (EPR) spectrometer.

  9. Nuclear Magnetic Resonance Gyroscope

    NASA Astrophysics Data System (ADS)

    Larsen, Michael; Griffith, Robert; Bulatowicz, Michael

    2014-03-01

    The navigation grade micro Nuclear Magnetic Resonance Gyroscope (micro-NMRG) being developed by the Northrop Grumman Corporation (NGC) has concluded the fourth and final phase of the DARPA Navigation Grade Integrated Micro Gyro (NGIMG) program. Traditional MEMS gyros utilize springs as an inherent part of the sensing mechanism, leading to bias and scale factor sensitivity to acceleration and vibration. As a result, they have not met performance expectations in real world environments and to date have been limited to tactical grade applications. The Nuclear Magnetic Resonance Gyroscope (NMRG) utilizes the fixed precession rate of a nuclear spin in a constant magnetic field as an inertial reference for determining rotation. The nuclear spin precession rate sensitivity to acceleration and vibration is negligible for most applications. Therefore, the application of new micro and batch fabrication methods to NMRG technology holds great promise for navigation grade performance in a low cost and compact gyro. This presentation will describe the operational principles, design basics, and demonstrated performance of the NMRG including an overview of the NGC designs developed and demonstrated in the DARPA gyro development program.

  10. Nuclear Magnetic Resonance Gyroscope

    NASA Astrophysics Data System (ADS)

    Bulatowicz, Michael; Clark, Philip; Griffith, Robert; Larsen, Michael; Mirijanian, James

    2012-06-01

    The navigation grade micro Nuclear Magnetic Resonance Gyroscope (micro-NMRG) being developed by the Northrop Grumman Corporation is concluding the fourth and final phase of the DARPA Navigation Grade Integrated Micro Gyro (NGIMG) program. Traditional MEMS gyros utilize springs as an inherent part of the sensing mechanism, leading to bias and scale factor sensitivity to acceleration and vibration. As a result, they have not met performance expectations in real world environments and to date have been limited to tactical grade applications. The Nuclear Magnetic Resonance Gyroscope (NMRG) utilizes the fixed precession rate of a nuclear spin in a constant magnetic field as an inertial reference for determining rotation. The nuclear spin precession rate sensitivity to acceleration and vibration is negligible for most applications. Therefore, the application of new micro and batch fabrication methods to NMRG technology holds great promise for navigation grade performance in a low cost and compact gyro. This poster will describe the history, operational principles, and design basics of the NMRG including an overview of the NSD designs developed and demonstrated in the DARPA gyro development program. General performance results from phases 3 and 4 will also be presented.

  11. Nuclear Magnetic Resonance Gyroscope

    NASA Astrophysics Data System (ADS)

    Bulatowicz, Michael; Griffith, Robert; Larsen, Michael

    2014-03-01

    The navigation grade micro Nuclear Magnetic Resonance Gyroscope (micro-NMRG) being developed by the Northrop Grumman Corporation (NGC) has concluded the fourth and final phase of the DARPA Navigation Grade Integrated Micro Gyro (NGIMG) program. Traditional MEMS gyros utilize springs as an inherent part of the sensing mechanism, leading to bias and scale factor sensitivity to acceleration and vibration. As a result, they have not met performance expectations in real world environments and to date have been limited to tactical grade applications. The Nuclear Magnetic Resonance Gyroscope (NMRG) utilizes the fixed precession rate of a nuclear spin in a constant magnetic field as an inertial reference for determining rotation. The nuclear spin precession rate sensitivity to acceleration and vibration is negligible for most applications. Therefore, the application of new micro and batch fabrication methods to NMRG technology holds great promise for navigation grade performance in a low cost and compact gyro. This poster will describe the history, operational principles, design, and demonstrated performance of the NMRG including an overview of the NGC designs developed and demonstrated in the DARPA gyro development program.

  12. Development of a high intensity laser for efficient spin exchange optical pumping in a spin maser measurement of the 129Xe EDM

    NASA Astrophysics Data System (ADS)

    Funayama, Chikako; Furukawa, Takeshi; Sato, Tomoya; Ichikawa, Yuichi; Ohtomo, Yuichi; Sakamoto, Yu; Kojima, Shuichiro; Suzuki, Takahiro; Chikamori, Masatoshi; Hikota, Eri; Tsuchiya, Masato; Yoshimi, Akihiro; Bidinosti, Christopher; Ino, Takashi; Ueno, Hideki; Matsuo, Yukari; Fukuyama, Takeshi; Asahi, Koichiro

    2014-09-01

    We aim to search for an atomic electric dipole moment (EDM) in 129Xe beyond the present upper limit at the level of 10-28 e cm. The enhancement of the spin polarization through the efficient spin-exchange optical pumping process is important for stable maser operation. Previously, a distributed feedback (DFB) laser and a spatially separated tapered amplifier (TA) were used for the optical pumping. The characteristics of the TA-DFB laser, such as its narrow line width and high frequency stability, enable us to produce a large spin polarization. However, the power of the TA-DFB laser was not sufficient for stable operation of the 3He spin-maser comagnetometer. Recently, we have been preparing a new laser system containing an external cavity laser diode (ECLD) and a more intense TA for more efficient pumping. In the presentation, we discuss the Rb and noble gases polarizations achieved with our new ECLD compared to that with the DFB laser, and evaluate the advantages gained by employing the ECLD.

  13. Magnetic resonance of slotted circular cylinder resonators

    NASA Astrophysics Data System (ADS)

    Du, Junjie; Liu, Shiyang; Lin, Zhifang; Chui, S. T.

    2008-07-01

    By a rigorous full-wave approach, a systemic study is made on the magnetic resonance of slotted circular cylinder resonators (SCCRs) made of a perfect conductor for the lossless case. This is a two-dimensional analog of the split-ring resonator and may serve as an alternative type of essential constituent of electromagnetic metamaterials. It is found that the resonance frequency can be modulated by changing the geometrical parameters and the dielectrics filling in the cavity and the slot. An approximate empirical expression is presented for magnetic resonance frequency of SCCRs from the viewpoint of an L-C circuit system. Finally, it is demonstrated that the SCCR structure can be miniaturized to less than 1/150 resonant wavelength in size with the dielectrics available currently.

  14. Nuclear Magnetic Resonance Gyroscope

    NASA Astrophysics Data System (ADS)

    Larsen, Michael

    2011-05-01

    The navigation grade micro Nuclear Magnetic Resonance Gyroscope (micro-NMRG) being developed by the Northrop Grumman Corporation is currently in phase 4 of the DARPA Navigation Grade Integrated Micro Gyro (NGIMG) program. The micro-NMRG technology is pushing the boundaries of size, weight, power, and performance allowing new small platform applications of navigation grade Inertial Navigation System (INS) technology. Information on the historical development of the technology, basics of operation, task performance goals, application opportunities, and a phase 2 sample of earth rate measurement data will be presented. Funding Provided by the Defense Advanced Research Projects Agency (DARPA)

  15. Cranial magnetic resonance imaging

    SciTech Connect

    Elster, A.D.

    1988-01-01

    Cranial Magnetic Resonance Imaging is comprehensive, well structured, and well written. The material is current and well referenced. The illustrations are good and complement the text well. The overall quality of publication is above average. The greatest attribute of the book is its readability. The author demonstrates ample skill in making complex subjects, such as MR physics and imaging of cerebral hemorrhage, easy to understand. The book closes with a detailed atlas on the anatomic appearance of the brain on MR images in the axial, coronal, and sagittal planes.

  16. Magnetic Resonance Imaging Duodenoscope.

    PubMed

    Syms, Richard R A; Young, Ian R; Wadsworth, Christopher A; Taylor-Robinson, Simon D; Rea, Marc

    2013-12-01

    A side-viewing duodenoscope capable of both optical and magnetic resonance imaging (MRI) is described. The instrument is constructed from MR-compatible materials and combines a coherent fiber bundle for optical imaging, an irrigation channel and a side-opening biopsy channel for the passage of catheter tools with a tip saddle coil for radio-frequency signal reception. The receiver coil is magnetically coupled to an internal pickup coil to provide intrinsic safety. Impedance matching is achieved using a mechanically variable mutual inductance, and active decoupling by PIN-diode switching. (1)H MRI of phantoms and ex vivo porcine liver specimens was carried out at 1.5 T. An MRI field-of-view appropriate for use during endoscopic retrograde cholangiopancreatography (ERCP) was obtained, with limited artefacts, and a signal-to-noise ratio advantage over a surface array coil was demonstrated. PMID:23807423

  17. Millimeter-wave spectroscopy and multichannel quantum-defect-theory analysis of high Rydberg states of xenon: The hyperfine structure of {sup 129}Xe{sup +} and {sup 131}Xe{sup +}

    SciTech Connect

    Schaefer, Martin; Raunhardt, Matthias; Merkt, Frederic

    2010-03-15

    Millimeter-wave transitions between high-n Rydberg states of several isotopes of xenon have been recorded at sub-megahertz resolution. The fine and, for {sup 129}Xe and {sup 131}Xe, hyperfine structures of s, p, d, and f Rydberg states with principal quantum number in the range 52{<=}n{<=}64 have been determined from combination differences and analyzed using multichannel quantum defect theory. Improved eigenquantum defects and channel interaction parameters for the odd- and even-parity Rydberg states of xenon and the hyperfine structure of the {sup 2}P{sub 3/2} ground state of {sup 129}Xe{sup +} and {sup 131}Xe{sup +} have been obtained. Nearly degenerate p and d fine or hyperfine levels are very easily mixed by even weak stray electric fields.

  18. Magnetic Resonance Elastography

    PubMed Central

    Litwiller, Daniel V.; Mariappan, Yogesh K.; Ehman, Richard L.

    2015-01-01

    Often compared to the practice of manual palpation, magnetic resonance elastography is an emerging technology for quantitatively assessing the mechanical properties of tissue as a basis for characterizing disease. The potential of MRE as a diagnostic tool is rooted in the fact that normal and diseased tissues often differ significantly in terms of their intrinsic mechanical properties. MRE uses magnetic resonance imaging (MRI) in conjunction with the application of mechanical shear waves to probe tissue mechanics. This process can be broken down into three essential steps: inducing shear waves in the tissue,imaging the propagating shear waves with MRI, andanalyzing the wave data to generate quantitative images of tissue stiffness MRE has emerged as a safe, reliable and noninvasive method for staging hepatic liver fibrosis, and is now used in some locations as an alternative to biopsy. MRE is also being used in the ongoing investigations of numerous other organs and tissues, including, for example, the spleen, kidney, pancreas, brain, heart, breast, skeletal muscle, prostate, vasculature, lung, spinal cord, eye, bone, and cartilage. In the article that follows, some fundamental techniques and applications of MRE are summarized. PMID:26361467

  19. 129Xe NMR of xenon adsorbed on the molecular sieves AlPO 4-11 and SAPO-11. Chemical shift anisotropy related to the asymmetry of the adsorption zones

    NASA Astrophysics Data System (ADS)

    Springuel-Huet, M. A.; Fraissard, J.

    1989-01-01

    The form of the 129Xe NMR signal of xenon adsorbed at low concentration on the molecular sieves SAPO-11 and AlPO 4-11 corresponds to a highly anisotropic chemical shift which expresses the asymmetry of the channels in which the xenon is located. To the asymmetry of the xenon-wall interaction is added that of the xenon-xenon interaction when the channels are largely filled.

  20. Accessible magnetic resonance imaging.

    PubMed

    Kaufman, L; Arakawa, M; Hale, J; Rothschild, P; Carlson, J; Hake, K; Kramer, D; Lu, W; Van Heteren, J

    1989-10-01

    The cost of magnetic resonance imaging (MRI) is driven by magnetic field strength. Misperceptions as to the impact of field strength on performance have led to systems that are more expensive than they need to be. Careful analysis of all the factors that affect diagnostic quality lead to the conclusion that field strength per se is not a strong determinant of system performance. Freed from the constraints imposed by high-field operation, it is possible to exploit a varied set of opportunities afforded by low-field operation. In addition to lower costs and easier siting, we can take advantage of shortened T1 times, higher contrast, reduced sensitivity to motion, and reduced radiofrequency power deposition. These conceptual advantages can be made to coalesce onto practical imaging systems. We describe a low-cost MRI system that utilizes a permanent magnet of open design. Careful optimization of receiving antennas and acquisition sequences permit performance levels consistent with those needed for an effective diagnostic unit. Ancillary advantages include easy access to the patient, reduced claustrophobia, quiet and comfortable operation, and absence of a missile effect. The system can be sited in 350 sq ft and consumes a modest amount of electricity. MRI equipment of this kind can widen the population base than can access this powerful and beneficial diagnostic modality. PMID:2640910

  1. Virtual magnetic resonance colonography

    PubMed Central

    Debatin, J; Lauenstein, T

    2003-01-01

    Colorectal cancer screening has vast potential. Beyond considerations for cost and diagnostic accuracy, the effectiveness of any colorectal screening strategy will be dependent on the degree of patient acceptance. Magnetic resonance (MR) colonography has been shown to be accurate regarding the detection of clinically relevant colonic polyps exceeding 10 mm in size, with reported sensitivity and specificity values exceeding 95%. To further increase patient acceptance, strategies for fecal tagging have recently been developed. By modulating the signal of fecal material to be identical to the signal characteristics of the enema applied to distend the colon, fecal tagging in conjunction with MR colonography obviates the need for bowel cleansing. The review will describe the techniques underlying MR colonography and describe early clinical experience with fecal tagging techniques. PMID:12746264

  2. Nuclear Magnetic Resonance Gyroscope

    NASA Astrophysics Data System (ADS)

    Larsen, Michael; Bulatowicz, Michael; Clark, Philip; Griffith, Robert; Mirijanian, James; Pavell, James

    2015-05-01

    The Nuclear Magnetic Resonance Gyroscope (NMRG) is being developed by the Northrop Grumman Corporation (NGC). Cold and hot atom interferometer based gyroscopes have suffered from Size, Weight, and Power (SWaP) challenges and limits in bandwidth, scale factor stability, dead time, high rotation rate, vibration, and acceleration. NMRG utilizes the fixed precession rate of a nuclear spin in a constant magnetic field as a reference for determining rotation, providing continuous measurement, high bandwidth, stable scale factor, high rotation rate measurement, and low sensitivity to vibration and acceleration in a low SWaP package. The sensitivity to vibration has been partially tested and demonstrates no measured sensitivity within error bars. Real time closed loop implementation of the sensor significantly decreases environmental and systematic sensitivities and supports a compact and low power digital signal processing and control system. Therefore, the NMRG technology holds great promise for navigation grade performance in a low cost SWaP package. The poster will describe the history, operation, and design of the NMRG. General performance results will also be presented along with recent vibration test results.

  3. Superconducting Magnets for Magnetic Resonance Imaging

    NASA Astrophysics Data System (ADS)

    Feenan, Peter

    2000-03-01

    MRI is now a well established diagnostic technique in medicine. The richness of information provided by magnetic resonance gives rise to a variety of techniques which in turn leads to a variety of magnet designs. Magnet designers must consider suitable superconduting materials for the magnet, but need also to consider the overall fomat of the magnet to maximise patient comfort, access for clinicians and convenience of use - in some examples magnets are destined for use within the operating theatre and special considerations are required for this. Magnet types include; (1) low-field general purpose imagers, (2) extremity imaging, (3) open magnets with exellent all-round access often employing iron or permanent magnetic materials, (4) high-field magnets, and (5) very high-field (7 Tesla and more) magnets for spectroscopy and functional imaging research. Examples of these magnet varieties will be shown and some of the design challenges discussed.

  4. Low field magnetic resonance imaging

    DOEpatents

    Pines, Alexander; Sakellariou, Dimitrios; Meriles, Carlos A.; Trabesinger, Andreas H.

    2010-07-13

    A method and system of magnetic resonance imaging does not need a large homogenous field to truncate a gradient field. Spatial information is encoded into the spin magnetization by allowing the magnetization to evolve in a non-truncated gradient field and inducing a set of 180 degree rotations prior to signal acquisition.

  5. Nuclear magnetic resonance contrast agents

    DOEpatents

    Smith, Paul H.; Brainard, James R.; Jarvinen, Gordon D.; Ryan, Robert R.

    1997-01-01

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC.sub.16 H.sub.14 N.sub.6. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques.

  6. Nuclear magnetic resonance contrast agents

    DOEpatents

    Smith, P.H.; Brainard, J.R.; Jarvinen, G.D.; Ryan, R.R.

    1997-12-30

    A family of contrast agents for use in magnetic resonance imaging and a method of enhancing the contrast of magnetic resonance images of an object by incorporating a contrast agent of this invention into the object prior to forming the images or during formation of the images. A contrast agent of this invention is a paramagnetic lanthanide hexaazamacrocyclic molecule, where a basic example has the formula LnC{sub 16}H{sub 14}N{sub 6}. Important applications of the invention are in medical diagnosis, treatment, and research, where images of portions of a human body are formed by means of magnetic resonance techniques. 10 figs.

  7. Functional magnetic resonance imaging.

    PubMed

    Buchbinder, Bradley R

    2016-01-01

    Functional magnetic resonance imaging (fMRI) maps the spatiotemporal distribution of neural activity in the brain under varying cognitive conditions. Since its inception in 1991, blood oxygen level-dependent (BOLD) fMRI has rapidly become a vital methodology in basic and applied neuroscience research. In the clinical realm, it has become an established tool for presurgical functional brain mapping. This chapter has three principal aims. First, we review key physiologic, biophysical, and methodologic principles that underlie BOLD fMRI, regardless of its particular area of application. These principles inform a nuanced interpretation of the BOLD fMRI signal, along with its neurophysiologic significance and pitfalls. Second, we illustrate the clinical application of task-based fMRI to presurgical motor, language, and memory mapping in patients with lesions near eloquent brain areas. Integration of BOLD fMRI and diffusion tensor white-matter tractography provides a road map for presurgical planning and intraoperative navigation that helps to maximize the extent of lesion resection while minimizing the risk of postoperative neurologic deficits. Finally, we highlight several basic principles of resting-state fMRI and its emerging translational clinical applications. Resting-state fMRI represents an important paradigm shift, focusing attention on functional connectivity within intrinsic cognitive networks. PMID:27432660

  8. Magnetic resonance energy and topological resonance energy.

    PubMed

    Aihara, Jun-Ichi

    2016-04-28

    Ring-current diamagnetism of a polycyclic π-system is closely associated with thermodynamic stability due to the individual circuits. Magnetic resonance energy (MRE), derived from the ring-current diamagnetic susceptibility, was explored in conjunction with graph-theoretically defined topological resonance energy (TRE). For many aromatic molecules, MRE is highly correlative with TRE with a correlation coefficient of 0.996. For all π-systems studied, MRE has the same sign as TRE. The only trouble with MRE may be that some antiaromatic and non-alternant species exhibit unusually large MRE-to-TRE ratios. This kind of difficulty can in principle be overcome by prior geometry-optimisation or by changing spin multiplicity. Apart from the semi-empirical resonance-theory resonance energy, MRE is considered as the first aromatic stabilisation energy (ASE) defined without referring to any hypothetical polyene reference. PMID:26878709

  9. Simple and Inexpensive Classroom Demonstrations of Nuclear Magnetic Resonance and Magnetic Resonance Imaging.

    ERIC Educational Resources Information Center

    Olson, Joel A.; Nordell, Karen J.; Chesnik, Marla A.; Landis, Clark R.; Ellis, Arthur B.; Rzchowski, M. S.; Condren, S. Michael; Lisensky, George C.

    2000-01-01

    Describes a set of simple, inexpensive, classical demonstrations of nuclear magnetic resonance (NMR) and magnetic resonance imaging (MRI) principles that illustrate the resonance condition associated with magnetic dipoles and the dependence of the resonance frequency on environment. (WRM)

  10. Magnetic Resonance Cholangiopancreatography (MRCP)

    MedlinePlus

    ... a powerful magnetic field, radio waves and a computer to evaluate the liver, gallbladder, bile ducts, pancreas ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  11. SQUID-Detected Magnetic Resonance Imaging in MicroteslaFields

    SciTech Connect

    Moessle, Michael; Hatridge, Michael; Clarke, John

    2006-08-14

    in MRI using laser polarized noble gases such as {sup 3}He or {sup 129}Xe (10-12). Hyperpolarized gases were used successfully to image the human lung in fields on the order of several mT (13-15). To overcome the sensitivity loss of Faraday detection at low frequencies, ultrasensitive magnetometers based on the Superconducting QUantum Interference Device (SQUID) (16) are used to detect NMR and MRI signals (17-24). Recently, SQUID-based MRI systems capable of acquiring in vivo images have appeared. For example, in the 10-mT system of Seton et al. (18) signals are coupled to a SQUID via a superconducting tuned circuit, while Clarke and coworkers (22, 25, 26) developed a system at 132 {micro}T with an untuned input circuit coupled to a SQUID. In a quite different approach, atomic magnetometers have been used recently to detect the magnetization (27) and NMR signal (28) of hyperpolarized gases. This technique could potentially be used for low-field MRI in the future. The goal of this review is to summarize the current state-of-the-art of MRI in microtesla fields detected with SQUIDs. The principles of SQUIDs and NMR are briefly reviewed. We show that very narrow NMR linewidths can be achieved in low magnetic fields that are quite inhomogeneous, with illustrative examples from spectroscopy. After describing our ultralow-field MRI system, we present a variety of images. We demonstrate that in microtesla fields the longitudinal relaxation T{sub 1} is much more material dependent than is the case in high fields; this results in a substantial improvement in 'T{sub 1}-weighted contrast imaging'. After outlining the first attempts to combine microtesla NMR with magnetoencephalography (MEG) (29), we conclude with a discussion of future directions.

  12. Noble gas magnetic resonator

    DOEpatents

    Walker, Thad Gilbert; Lancor, Brian Robert; Wyllie, Robert

    2014-04-15

    Precise measurements of a precessional rate of noble gas in a magnetic field is obtained by constraining the time averaged direction of the spins of a stimulating alkali gas to lie in a plane transverse to the magnetic field. In this way, the magnetic field of the alkali gas does not provide a net contribution to the precessional rate of the noble gas.

  13. Basics of magnetic resonance imaging

    SciTech Connect

    Oldendorf, W.; Oldendorf, W. Jr.

    1988-01-01

    Beginning with the behavior of a compass needle in a magnetic field, this text uses analogies from everyday experience to explain the phenomenon of nuclear magnetic resonance and how it is used for imaging. Using a minimum of scientific abbreviations and symbols, the basics of tissue visualization and characterization are presented. A description of the various types of magnets and scanners is followed by the practical advantages and limitations of MRI relative to x-ray CT scanning.

  14. Optically detected magnetic resonance imaging

    SciTech Connect

    Blank, Aharon; Shapiro, Guy; Fischer, Ran; London, Paz; Gershoni, David

    2015-01-19

    Optically detected magnetic resonance provides ultrasensitive means to detect and image a small number of electron and nuclear spins, down to the single spin level with nanoscale resolution. Despite the significant recent progress in this field, it has never been combined with the power of pulsed magnetic resonance imaging techniques. Here, we demonstrate how these two methodologies can be integrated using short pulsed magnetic field gradients to spatially encode the sample. This result in what we denote as an 'optically detected magnetic resonance imaging' technique. It offers the advantage that the image is acquired in parallel from all parts of the sample, with well-defined three-dimensional point-spread function, and without any loss of spectroscopic information. In addition, this approach may be used in the future for parallel but yet spatially selective efficient addressing and manipulation of the spins in the sample. Such capabilities are of fundamental importance in the field of quantum spin-based devices and sensors.

  15. GHz nuclear magnetic resonance

    SciTech Connect

    Cross, T.A.; Drobny, G.; Trewhella, J.

    1994-12-01

    For the past dozen years, 500- and 600-MHz spectrometers have become available in many laboratories. The first 600-MHz NMR spectrometer (at Carnegie Mellon University) was commissioned more than 15 years ago and, until 1994, represented the highest field available for high-resolution NMR. This year, we have witnessed unprecedented progress in the development of very high field magnets for NMR spectroscopy, including the delivery of the first commercial 750-MHz NMR spectrometers. In addition, NMR signals have been obtained from 20-Tesla magnets (850 MHz for {sup 1}H`s) at both Los Alamos National Laboratory and Florida State University in the NHMFL (National High Magnetic Field Laboratory). These preliminary experiments have been performed in magnets with 100-ppm homogeneity, but a 20-Tesla magnet developed for the NHMFL will be brought to field this year with a projected homogeneity of 0.1 ppm over a 1-cm-diam spherical volume.

  16. Magnetic resonance apparatus

    DOEpatents

    Jackson, Jasper A.; Cooper, Richard K.

    1982-01-01

    Means for producing a region of homogeneous magnetic field remote from the source of the field, wherein two equal field sources are arranged axially so their fields oppose, producing a region near the plane perpendicular to the axis midway between the sources where the radial component of the field goes through a maximum. Near the maximum, the field is homogeneous over prescribed regions.

  17. Nuclear magnetic resonance spectroscopy

    SciTech Connect

    Harris, R.K.

    1986-01-01

    NMR is remarkable in the number of innovations that have appeared and become established within the past five years. This thoroughly up-to-date account of the field explains fundamentals and applications of the NMR phenomenon from the viewpoint of a physical chemist. Beginning with descriptions of basic concepts involved in continuous wave operation, the book goes on to cover spectral analysis, relaxation phenomena, the effects of pulses, the Fourier transform model, double resonance and the effects of chemical exchange and quadrupolar interactions. The book also includes the new techniques for work on solids and for complicated pulse sequences, plus abundant figures and illustrative spectra.

  18. Magnetic resonance apparatus

    DOEpatents

    Jackson, J.A.; Cooper, R.K.

    1980-10-10

    The patent consists of means for producing a region of homogeneous magnetic field remote from the source of the field, wherein two equal field sources are arranged axially so their fields oppose, producing a region near the plane perpendicular to the axis midway between the sources where the radial correspondent of the field goes through a maximum. Near the maximum, the field is homogeneous over prescribed regions.

  19. Pediatric Body Magnetic Resonance Imaging.

    PubMed

    Kandasamy, Devasenathipathy; Goyal, Ankur; Sharma, Raju; Gupta, Arun Kumar

    2016-09-01

    Magnetic resonance imaging (MRI) is a radiation-free imaging modality with excellent contrast resolution and multiplanar capabilities. Since ionizing radiation is an important concern in the pediatric population, MRI serves as a useful alternative to computed tomography (CT) and also provides additional clues to diagnosis, not discernible on other investigations. Magnetic resonance cholangiopancreatography (MRCP), urography, angiography, enterography, dynamic multiphasic imaging and diffusion-weighted imaging provide wealth of information. The main limitations include, long scan time, need for sedation/anesthesia, cost and lack of widespread availability. With the emergence of newer sequences and variety of contrast agents, MRI has become a robust modality and may serve as a one-stop shop for both anatomical and functional information. PMID:26916887

  20. Direct measurement of the γHe / γXe ratio at ultralow magnetic field

    NASA Astrophysics Data System (ADS)

    Fan, Isaac; Knappe-Grüneberg, Silvia; Voigt, Jens; Kilian, Wolfgang; Burghoff, Martin; Stollfuss, Detlef; Schnabel, Allard; Wübbeler, Gerd; Bodner, Olha; Elster, Clemens; Seifert, Frank; Trahms, Lutz

    2016-06-01

    A co-located 3He and 129Xe nuclear spin free precession measurement at sub-μT magnetic field was carried out in a magnetically shielded environment. The uncorrected quotient of the gyromagnetic ratios between neutral 3He and 129Xe atoms is determined to be 2.754 082 81(07), accounting for only statistical error. Our measurement shows that this ratio has a stability of 1.4×10-5/ √τ, demonstrating the ability to reach the current precision limit of the quotient in a 10000 s of averaging time τ. This precision is enough for the next-generation EDM search in neutral 129Xe atoms based on a similar comagnetometer scheme.

  1. Wide-range nuclear magnetic resonance detector

    NASA Technical Reports Server (NTRS)

    Sturman, J. C.; Jirberg, R. J.

    1972-01-01

    Compact and easy to use solid state nuclear magnetic resonance detector is designed for measuring field strength to 20 teslas in cryogenically cooled magnets. Extremely low noise and high sensitivity make detector applicable to nearly all types of analytical nuclear magnetic resonance measurements and can be used in high temperature and radiation environments.

  2. Evanescent Waves Nuclear Magnetic Resonance

    PubMed Central

    Halidi, El Mohamed; Nativel, Eric; Akel, Mohamad; Kenouche, Samir; Coillot, Christophe; Alibert, Eric; Jabakhanji, Bilal; Schimpf, Remy; Zanca, Michel; Stein, Paul; Goze-Bac, Christophe

    2016-01-01

    Nuclear Magnetic Resonance spectroscopy and imaging can be classified as inductive techniques working in the near- to far-field regimes. We investigate an alternative capacitive detection with the use of micrometer sized probes positioned at sub wavelength distances of the sample in order to characterize and model evanescent electromagnetic fields originating from NMR phenomenon. We report that in this experimental configuration the available NMR signal is one order of magnitude larger and follows an exponential decay inversely proportional to the size of the emitters. Those investigations open a new road to a better understanding of the evanescent waves component in NMR with the opportunity to perform localized spectroscopy and imaging. PMID:26751800

  3. Introduction to Nuclear Magnetic Resonance

    NASA Technical Reports Server (NTRS)

    Manatt, Stanley L.

    1985-01-01

    The purpose of this paper is to try to give a short overview of what the status is on nuclear magnetic resonance (NMR). It's a subject where one really has to spend some time to look at the physics in detail to develop a proper working understanding. I feel it's not appropriate to present to you density matrices, Hamiltonians of all sorts, and differential equations representing the motion of spins. I'm really going to present some history and status, and show a few very simple concepts involved in NMR. It is a form of radio frequency spectroscopy and there are a great number of nuclei that can be studied very usefully with the technique. NMR requires a magnet, a r.f. transmitter/receiver system, and a data acquisition system.

  4. Magnetic resonance imaging of acquired cardiac disease.

    PubMed Central

    Carrol, C L; Higgins, C B; Caputo, G R

    1996-01-01

    Over the last 15 years, advances in magnetic resonance imaging techniques have increased the accuracy and applicability of cardiovascular magnetic resonance imaging. These advances have improved the utility of magnetic resonance imaging in evaluating cardiac morphology, blood flow, and myocardial contractility, all significant diagnostic features in the evaluation of the patient with acquired heart disease. Utilization of cardiovascular magnetic resonance imaging has been limited, primarily due to clinical reliance upon nuclear scintigraphy and echocardiography. Recent developments in fast and ultrafast imaging should continue to enhance the significance of magnetic resonance imaging in this field. Widespread use of magnetic resonance imaging in the evaluation of the cardiovascular system will ultimately depend upon its maturation into a comprehensive, noninvasive imaging technique for the varying manifestations of acquired heart disease, including cardiomyopathy, ischemic heart disease, and acquired valvular disease. Images PMID:8792545

  5. Magnetic resonance imaging of the spine

    SciTech Connect

    Modic, M.

    1988-01-01

    MAGNETIC RESONANCE IMAGING OF THE SPINE thoroughly demonstrates the advantages of this new radiologic modality in diagnosing spinal disorders. The book begins with an introductory chapter on the basic physics and technical considerations of magnetic resonance in general and magnetic resonance imaging of the spine in particular. The second chapter covers normal spinal anatomy, and features color photos of multi-planar sections of spinal anatomy.

  6. Practical applications of cardiovascular magnetic resonance

    PubMed Central

    Alpendurada, F; Wong, J; Pennell, D J

    2009-01-01

    Recent developments in magnetic resonance imaging have focused attention on evaluation of patients with cardiac disease. These improvements have been substantiated by a large and expanding body of clinical evidence, making cardiovascular magnetic resonance the imaging modality of choice in a wide variety of cardiovascular disorders. A brief review on the current applications of cardiovascular magnetic resonance is provided, with reference to some of the most relevant studies, statements and reviews published in this field.

  7. Tunable Magnetic Resonance in Microwave Spintronics Devices

    NASA Technical Reports Server (NTRS)

    Chen, Yunpeng; Fan, Xin; Xie, Yungsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe-based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  8. Tunable Magnetic Resonance in Microwave Spintronics Devices

    NASA Technical Reports Server (NTRS)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Zhou, Yang; Wang, Tao; Wilson, Jeffrey D.; Simons, Rainee N.; Chui, Sui-Tat; Xiao, John Q.

    2015-01-01

    Magnetic resonance is one of the key properties of magnetic materials for the application of microwave spintronics devices. The conventional method for tuning magnetic resonance is to use an electromagnet, which provides very limited tuning range. Hence, the quest for enhancing the magnetic resonance tuning range without using an electromagnet has attracted tremendous attention. In this paper, we exploit the huge exchange coupling field between magnetic interlayers, which is on the order of 4000 Oe and also the high frequency modes of coupled oscillators to enhance the tuning range. Furthermore, we demonstrate a new scheme to control the magnetic resonance frequency. Moreover, we report a shift in the magnetic resonance frequency as high as 20 GHz in CoFe based tunable microwave spintronics devices, which is 10X higher than conventional methods.

  9. Assessment of Lung Function in Asthma and COPD using Hyperpolarized 129Xe Chemical Shift Saturation Recovery Spectroscopy and Dissolved-Phase MR Imaging

    PubMed Central

    Qing, Kun; Mugler, John P.; Altes, Talissa A.; Jiang, Yun; Mata, Jaime F.; Miller, G. Wilson; Ruset, Iulian C.; Hersman, F. William; Ruppert, Kai

    2014-01-01

    Magnetic-resonance spectroscopy and imaging using hyperpolarized xenon-129 show great potential for evaluation of the most important function of the human lung -- gas exchange. In particular, Chemical Shift Saturation Recovery (CSSR) xenon-129 spectroscopy provides important physiological information for the lung as a whole by characterizing the dynamic process of gas exchange, while dissolved-phase xenon-129 imaging captures the time-averaged regional distribution of gas uptake by lung tissue and blood. Herein, we present recent advances in assessing lung function using CSSR spectroscopy and dissolved-phase imaging in a total of 45 subjects (23 healthy, 13 chronic obstructive pulmonary disease (COPD) and 9 asthma). From CSSR acquisitions, the COPD subjects showed red blood cell to tissue/plasma (RBC-to-TP) ratios below the average for the healthy subjects (p<0.001), but significantly higher septal wall thicknesses, as compared with the healthy subjects (p<0.005); the RBC-to-TP ratios for the asthmatics fell outside 2 standard deviations (either higher or lower) from the mean of the healthy subjects although there was no statistically significant difference for the average ratio of the study group as a whole. Similarly, from the 3D DP imaging acquisitions, we found all the ratios (TP-to-GP, RBC-to-GP, RBC-to-TP) measured in the COPD subjects were lower than those from the healthy subjects (p<0.05 for all ratios), while these ratios in the asthmatics differed considerably between subjects. Despite having been performed at different lung inflation levels, the RBC-to-TP ratios measured by CSSR and 3D DP imaging were fairly consistent with each other, with a mean difference of 0.037 (ratios from 3D DP imaging larger). In ten subjects the RBC-to-GP ratios obtained from the 3D DP imaging acquisitions were also highly correlated with their DLCO/Va ratios measured by pulmonary function testing (R=0.91). PMID:25146558

  10. Apparatus for investigating resonance with application to magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Murphy, Sytil; Jones, Dyan L.; Gross, Josh; Zollman, Dean

    2015-11-01

    Resonance is typically studied in the context of either a pendulum or a mass on a spring. We have developed an apparatus that enables beginning students to investigate resonant behavior of changing magnetic fields, in addition to the properties of the magnetic field due to a wire and the superposition of magnetic fields. In this resonant system, a compass oscillates at a frequency determined by the compass's physical properties and an external magnetic field. While the analysis is mathematically similar to that of the pendulum, this apparatus has an advantage that the magnetic field is easily controlled, while it is difficult to control the strength of gravity. This apparatus has been incorporated into a teaching module on magnetic resonance imaging.

  11. Atomic electric dipole moment induced by the nuclear electric dipole moment: The magnetic moment effect

    SciTech Connect

    Porsev, S. G.; Ginges, J. S. M.; Flambaum, V. V.

    2011-04-15

    We have considered a mechanism for inducing a time-reversal violating electric dipole moment (EDM) in atoms through the interaction of a nuclear EDM d{sub N} with the hyperfine interaction, the ''magnetic moment effect''. We have derived the operator for this interaction and presented analytical formulas for the matrix elements between atomic states. Induced EDMs in the diamagnetic atoms {sup 129}Xe, {sup 171}Yb, {sup 199}Hg, {sup 211}Rn, and {sup 225}Ra have been calculated numerically. From the experimental limits on the atomic EDMs of {sup 129}Xe and {sup 199}Hg we have placed the following constraints on the nuclear EDMs, |d{sub N}({sup 129}Xe)|<1.1x10{sup -21}|e|cm and |d{sub N}({sup 199}Hg)|<2.8x10{sup -24}|e|cm.

  12. MAGNETIC RESONANCE ELASTOGRAPHY: A REVIEW

    PubMed Central

    Mariappan, Yogesh K; Glaser, Kevin J; Ehman, Richard L

    2011-01-01

    Magnetic Resonance Elastography (MRE) is a rapidly developing technology for quantitatively assessing the mechanical properties of tissue. The technology can be considered to be an imaging-based counterpart to palpation, commonly used by physicians to diagnose and characterize diseases. The success of palpation as a diagnostic method is based on the fact that the mechanical properties of tissues are often dramatically affected by the presence of disease processes such as cancer, inflammation, and fibrosis. MRE obtains information about the stiffness of tissue by assessing the propagation of mechanical waves through the tissue with a special magnetic resonance imaging (MRI) technique. The technique essentially involves three steps: generating shear waves in the tissue,acquiring MR images depicting the propagation of the induced shear waves andprocessing the images of the shear waves to generate quantitative maps of tissue stiffness, called elastograms. MRE is already being used clinically for the assessment of patients with chronic liver diseases and is emerging as a safe, reliable and noninvasive alternative to liver biopsy for staging hepatic fibrosis. MRE is also being investigated for application to pathologies of other organs including the brain, breast, blood vessels, heart, kidneys, lungs and skeletal muscle. The purpose of this review article is to introduce this technology to clinical anatomists and to summarize some of the current clinical applications that are being pursued. PMID:20544947

  13. Advances in mechanical detection of magnetic resonance

    PubMed Central

    Kuehn, Seppe; Hickman, Steven A.; Marohn, John A.

    2008-01-01

    The invention and initial demonstration of magnetic resonance force microscopy (MRFM) in the early 1990s launched a renaissance of mechanical approaches to detecting magnetic resonance. This article reviews progress made in MRFM in the last decade, including the demonstration of scanned probe detection of magnetic resonance (electron spin resonance, ferromagnetic resonance, and nuclear magnetic resonance) and the mechanical detection of electron spin resonance from a single spin. Force and force-gradient approaches to mechanical detection are reviewed and recent related work using attonewton sensitivity cantilevers to probe minute fluctuating electric fields near surfaces is discussed. Given recent progress, pushing MRFM to single proton sensitivity remains an exciting possibility. We will survey some practical and fundamental issues that must be resolved to meet this challenge. PMID:18266413

  14. Torque-mixing magnetic resonance spectroscopy.

    PubMed

    Losby, J E; Fani Sani, F; Grandmont, D T; Diao, Z; Belov, M; Burgess, J A J; Compton, S R; Hiebert, W K; Vick, D; Mohammad, K; Salimi, E; Bridges, G E; Thomson, D J; Freeman, M R

    2015-11-13

    A universal, torque-mixing method for magnetic resonance spectroscopy is presented. In analogy to resonance detection by magnetic induction, the transverse component of a precessing dipole moment can be measured in sensitive broadband spectroscopy, here using a resonant mechanical torque sensor. Unlike induction, the torque amplitude allows equilibrium magnetic properties to be monitored simultaneously with the spin dynamics. Comprehensive electron spin resonance spectra of a single-crystal, mesoscopic yttrium iron garnet disk at room temperature reveal assisted switching between magnetization states and mode-dependent spin resonance interactions with nanoscale surface imperfections. The rich detail allows analysis of even complex three-dimensional spin textures. The flexibility of microelectromechanical and optomechanical devices combined with broad generality and capabilities of torque-mixing magnetic resonance spectroscopy offers great opportunities for development of integrated devices. PMID:26564851

  15. Electron Paramagnetic Resonance -- Nuclear Magnetic Resonance Three Axis Vector Magnetometer

    NASA Astrophysics Data System (ADS)

    Bulatowicz, Michael; Clark, Philip; Griffith, Robert; Larsen, Michael; Mirijanian, James

    2012-06-01

    The Northrop Grumman Corporation is leveraging the technology developed for the Nuclear Magnetic Resonance Gyroscope (NMRG) to build a combined Electron Paramagnetic Resonance -- Nuclear Magnetic Resonance (EPR-NMR) magnetometer. The EPR-NMR approach provides a high bandwidth and high sensitivity simultaneous measurement of all three vector components of the magnetic field averaged over the small volume of the sensor's one vapor cell. This poster will describe the history, operational principles, and design basics of the EPR-NMR magnetometer including an overview of the NSD designs developed and demonstrated to date. General performance results will also be presented.

  16. Functional Magnetic Resonance Imaging Methods

    PubMed Central

    Chen, Jingyuan E.; Glover, Gary H.

    2015-01-01

    Since its inception in 1992, Functional Magnetic Resonance Imaging (fMRI) has become an indispensible tool for studying cognition in both the healthy and dysfunctional brain. FMRI monitors changes in the oxygenation of brain tissue resulting from altered metabolism consequent to a task-based evoked neural response or from spontaneous fluctuations in neural activity in the absence of conscious mentation (the “resting state”). Task-based studies have revealed neural correlates of a large number of important cognitive processes, while fMRI studies performed in the resting state have demonstrated brain-wide networks that result from brain regions with synchronized, apparently spontaneous activity. In this article, we review the methods used to acquire and analyze fMRI signals. PMID:26248581

  17. Magnetic Resonance Imaging of Electrolysis.

    PubMed Central

    Meir, Arie; Hjouj, Mohammad; Rubinsky, Liel; Rubinsky, Boris

    2015-01-01

    This study explores the hypothesis that Magnetic Resonance Imaging (MRI) can image the process of electrolysis by detecting pH fronts. The study has relevance to real time control of cell ablation with electrolysis. To investigate the hypothesis we compare the following MR imaging sequences: T1 weighted, T2 weighted and Proton Density (PD), with optical images acquired using pH-sensitive dyes embedded in a physiological saline agar solution phantom treated with electrolysis and discrete measurements with a pH microprobe. We further demonstrate the biological relevance of our work using a bacterial E. Coli model, grown on the phantom. The results demonstrate the ability of MRI to image electrolysis produced pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E. Coli model grown on the phantom. The results are promising and invite further experimental research. PMID:25659942

  18. Magnetic resonance elastography of abdomen.

    PubMed

    Venkatesh, Sudhakar Kundapur; Ehman, Richard L

    2015-04-01

    Many diseases cause substantial changes in the mechanical properties of tissue, and this provides motivation for developing methods to noninvasively assess the stiffness of tissue using imaging technology. Magnetic resonance elastography (MRE) has emerged as a versatile MRI-based technique, based on direct visualization of propagating shear waves in the tissues. The most established clinical application of MRE in the abdomen is in chronic liver disease. MRE is currently regarded as the most accurate noninvasive technique for detection and staging of liver fibrosis. Increasing experience and ongoing research is leading to exploration of applications in other abdominal organs. In this review article, the current use of MRE in liver disease and the potential future applications of this technology in other parts of the abdomen are surveyed. PMID:25488346

  19. Magnetic Resonance Imaging of Electrolysis.

    NASA Astrophysics Data System (ADS)

    Meir, Arie; Hjouj, Mohammad; Rubinsky, Liel; Rubinsky, Boris

    2015-02-01

    This study explores the hypothesis that Magnetic Resonance Imaging (MRI) can image the process of electrolysis by detecting pH fronts. The study has relevance to real time control of cell ablation with electrolysis. To investigate the hypothesis we compare the following MR imaging sequences: T1 weighted, T2 weighted and Proton Density (PD), with optical images acquired using pH-sensitive dyes embedded in a physiological saline agar solution phantom treated with electrolysis and discrete measurements with a pH microprobe. We further demonstrate the biological relevance of our work using a bacterial E. Coli model, grown on the phantom. The results demonstrate the ability of MRI to image electrolysis produced pH changes in a physiological saline phantom and show that these changes correlate with cell death in the E. Coli model grown on the phantom. The results are promising and invite further experimental research.

  20. Magnetic Resonance Elastography of Abdomen

    PubMed Central

    Venkatesh, Sudhakar K.; Ehman, Richard L.

    2015-01-01

    Many diseases cause substantial changes in the mechanical properties of tissue and this provides motivation for developing methods to non-invasively assess the stiffness of tissue using imaging technology. Magnetic resonance elastography (MRE) has emerged as a versatile MRI-based technique, based on direct visualization of propagating shear waves in the tissues. The most established clinical application of MRE in the abdomen is in chronic liver disease. MRE is currently regarded as the most accurate non-invasive technique for detection and staging of liver fibrosis. Increasing experience and ongoing research is leading to exploration of applications in other abdominal organs. In this review article, the current use of MRE in liver disease and the potential future applications of this technology in other parts of the abdomen are surveyed. PMID:25488346

  1. Magnetic resonance sees lesions of multiple sclerosis

    SciTech Connect

    Ziporyn, T.

    1985-02-15

    The value of nuclear magnetic resonance imaging in the diagnosis and quantitation of the progression of multiple sclerosis is discussed. Magnetic resonance imaging generates images that reflect differential density and velocity of hydrogen nuclei between cerebral gray and white matter, as well as between white matter and pathological lesions of the disease.

  2. Enhancement of Magnetic Resonance Imaging with Metasurfaces.

    PubMed

    Slobozhanyuk, Alexey P; Poddubny, Alexander N; Raaijmakers, Alexander J E; van den Berg, Cornelis A T; Kozachenko, Alexander V; Dubrovina, Irina A; Melchakova, Irina V; Kivshar, Yuri S; Belov, Pavel A

    2016-03-01

    It is revealed that the unique properties of ultrathin metasurface resonators can improve magnetic resonance imaging dramatically. A metasurface formed when an array of metallic wires is placed inside a scanner under the studied object and a substantial enhancement of the radio-frequency magnetic field is achieved by means of subwavelength manipulation with the metasurface, also allowing improved image resolution. PMID:26754827

  3. Chemical Principles Revisited. Proton Magnetic Resonance Spectroscopy.

    ERIC Educational Resources Information Center

    McQuarrie, Donald A.

    1988-01-01

    Discusses how to interpret nuclear magnetic resonance (NMR) spectra and how to use them to determine molecular structures. This discussion is limited to spectra that are a result of observation of only the protons in a molecule. This type is called proton magnetic resonance (PMR) spectra. (CW)

  4. Magnetic resonance imaging of radiation optic neuropathy

    SciTech Connect

    Zimmerman, C.F.; Schatz, N.J.; Glaser, J.S. )

    1990-10-15

    Three patients with delayed radiation optic neuropathy after radiation therapy for parasellar neoplasms underwent magnetic resonance imaging. The affected optic nerves and chiasms showed enlargement and focal gadopentetate dimeglumine enhancement. The magnetic resonance imaging technique effectively detected and defined anterior visual pathway changes of radionecrosis and excluded the clinical possibility of visual loss because of tumor recurrence.

  5. Functional Magnetic Resonance Imaging and Pediatric Anxiety

    ERIC Educational Resources Information Center

    Pine, Daniel S.; Guyer, Amanda E.; Leibenluft, Ellen; Peterson, Bradley S.; Gerber, Andrew

    2008-01-01

    The use of functional magnetic resonance imaging in investigating pediatric anxiety disorders is studied. Functional magnetic resonance imaging can be utilized in demonstrating parallels between the neural architecture of difference in anxiety of humans and the neural architecture of attention-orienting behavior in nonhuman primates or rodents.…

  6. Magnetic resonance imaging of glioblastoma using aptamer conjugated magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Kim, Bongjune; Yang, Jaemoon; Hwang, Myeonghwan; Suh, Jin-Suck; Huh, Yong-Min; Haam, Seungjoo

    2012-10-01

    Here we introduce a new class of smart imaging probes hybridizing polysorbate 80 coated-magnetic nanoparticles with vascular endothelial growth factor receptor 2 (VEGFR2)-targetable aptamer for specific magnetic resonance (MR) imaging of angiogenesis from glioblastoma.

  7. Tunable Magnetic Resonance via Interlayer Exchange Interaction

    NASA Astrophysics Data System (ADS)

    Chen, Yunpeng; Fan, Xin; Xie, Yunsong; Wilson, Jeffrey; Simons, Rainee; Chui, Sui-Tat; Xiao, John

    Magnetic resonance is a critical property of magnetic materials for the applications in microwave devices and novel spintronics devices. The resonance frequency is commonly controlled with an external magnetic field generated by an energy-inefficient and bulky electromagnet. The search for tuning the resonance frequency without electromagnets has attracted tremendous attention. The voltage control of resonance frequency has been demonstrated in multiferroic heterostructures through magnetoelastic effect. However, the frequency tunable range is limited. We propose a paradigm to tune the magnetic resonance frequency by recognizing the huge interlayer exchange field and the existence of the high-frequency modes in coupled oscillators. We demonstrate the optical mode in exchange coupled magnetic layers which occurred at much higher frequencies than coherent ferromagnetic resonance. We further demonstrated a large resonance frequency tunable range from 11GHz to 21 GHz in a spin valve device by in-situ manipulating of the exchange interaction. The technique developed here is far more efficient than the conventional methods of using electromagnets and multiferroics. This new scheme will have an immediate impact on applications based on magnetic resonance.

  8. Artifacts in Magnetic Resonance Imaging

    PubMed Central

    Krupa, Katarzyna; Bekiesińska-Figatowska, Monika

    2015-01-01

    Summary Artifacts in magnetic resonance imaging and foreign bodies within the patient’s body may be confused with a pathology or may reduce the quality of examinations. Radiologists are frequently not informed about the medical history of patients and face postoperative/other images they are not familiar with. A gallery of such images was presented in this manuscript. A truncation artifact in the spinal cord could be misinterpreted as a syrinx. Motion artifacts caused by breathing, cardiac movement, CSF pulsation/blood flow create a ghost artifact which can be reduced by patient immobilization, or cardiac/respiratory gating. Aliasing artifacts can be eliminated by increasing the field of view. An artificially hyperintense signal on FLAIR images can result from magnetic susceptibility artifacts, CSF/vascular pulsation, motion, but can also be found in patients undergoing MRI examinations while receiving supplemental oxygen. Metallic and other foreign bodies which may be found on and in patients’ bodies are the main group of artifacts and these are the focus of this study: e.g. make-up, tattoos, hairbands, clothes, endovascular embolization, prostheses, surgical clips, intraorbital and other medical implants, etc. Knowledge of different types of artifacts and their origin, and of possible foreign bodies is necessary to eliminate them or to reduce their negative influence on MR images by adjusting acquisition parameters. It is also necessary to take them into consideration when interpreting the images. Some proposals of reducing artifacts have been mentioned. Describing in detail the procedures to avoid or limit the artifacts would go beyond the scope of this paper but technical ways to reduce them can be found in the cited literature. PMID:25745524

  9. Stepped Impedance Resonators for High Field Magnetic Resonance Imaging

    PubMed Central

    Akgun, Can E.; DelaBarre, Lance; Yoo, Hyoungsuk; Sohn, Sung-Min; Snyder, Carl J.; Adriany, Gregor; Ugurbil, Kamil; Gopinath, Anand; Vaughan, J. Thomas

    2014-01-01

    Multi-element volume radio-frequency (RF) coils are an integral aspect of the growing field of high field magnetic resonance imaging (MRI). In these systems, a popular volume coil of choice has become the transverse electromagnetic (TEM) multi-element transceiver coil consisting of microstrip resonators. In this paper, to further advance this design approach, a new microstrip resonator strategy in which the transmission line is segmented into alternating impedance sections referred to as stepped impedance resonators (SIRs) is investigated. Single element simulation results in free space and in a phantom at 7 tesla (298 MHz) demonstrate the rationale and feasibility of the SIR design strategy. Simulation and image results at 7 tesla in a phantom and human head illustrate the improvements in transmit magnetic field, as well as, RF efficiency (transmit magnetic field versus SAR) when two different SIR designs are incorporated in 8-element volume coil configurations and compared to a volume coil consisting of microstrip elements. PMID:23508243

  10. Enhancement of artificial magnetism via resonant bianisotropy.

    PubMed

    Markovich, Dmitry; Baryshnikova, Kseniia; Shalin, Alexander; Samusev, Anton; Krasnok, Alexander; Belov, Pavel; Ginzburg, Pavel

    2016-01-01

    All-dielectric "magnetic light" nanophotonics based on high refractive index nanoparticles allows controlling magnetic component of light at nanoscale without having high dissipative losses. The artificial magnetic optical response of such nanoparticles originates from circular displacement currents excited inside those structures and strongly depends on geometry and dispersion of optical materials. Here an approach for enhancing of magnetic response via resonant bianisotropy effect is proposed and analyzed. The key mechanism of enhancement is based on electric-magnetic interaction between two electrically and magnetically resonant nanoparticles of all-dielectric dimer. It was shown that proper geometrical arrangement of the dimer in respect to the incident illumination direction allows flexible control over all vectorial components of the magnetic moment, tailoring the latter in the dynamical range of 100% and delivering enhancement up to 36% relative to performances of standalone spherical particles. The proposed approach provides pathways for designs of all-dielectric metamaterials and metasurfaces with strong magnetic responses. PMID:26941126

  11. Enhancement of artificial magnetism via resonant bianisotropy

    NASA Astrophysics Data System (ADS)

    Markovich, Dmitry; Baryshnikova, Kseniia; Shalin, Alexander; Samusev, Anton; Krasnok, Alexander; Belov, Pavel; Ginzburg, Pavel

    2016-03-01

    All-dielectric “magnetic light” nanophotonics based on high refractive index nanoparticles allows controlling magnetic component of light at nanoscale without having high dissipative losses. The artificial magnetic optical response of such nanoparticles originates from circular displacement currents excited inside those structures and strongly depends on geometry and dispersion of optical materials. Here an approach for enhancing of magnetic response via resonant bianisotropy effect is proposed and analyzed. The key mechanism of enhancement is based on electric-magnetic interaction between two electrically and magnetically resonant nanoparticles of all-dielectric dimer. It was shown that proper geometrical arrangement of the dimer in respect to the incident illumination direction allows flexible control over all vectorial components of the magnetic moment, tailoring the latter in the dynamical range of 100% and delivering enhancement up to 36% relative to performances of standalone spherical particles. The proposed approach provides pathways for designs of all-dielectric metamaterials and metasurfaces with strong magnetic responses.

  12. Reducing Field Distortion in Magnetic Resonance Imaging

    NASA Technical Reports Server (NTRS)

    Eom, Byeong Ho; Penanen, Konstantin; Hahn, Inseob

    2010-01-01

    A concept for a magnetic resonance imaging (MRI) system that would utilize a relatively weak magnetic field provides for several design features that differ significantly from the corresponding features of conventional MRI systems. Notable among these features are a magnetic-field configuration that reduces (relative to the conventional configuration) distortion and blurring of the image, the use of a superconducting quantum interference device (SQUID) magnetometer as the detector, and an imaging procedure suited for the unconventional field configuration and sensor. In a typical application of MRI, a radio-frequency pulse is used to excite precession of the magnetic moments of protons in an applied magnetic field, and the decaying precession is detected for a short time following the pulse. The precession occurs at a resonance frequency proportional to the strengths of the magnetic field and the proton magnetic moment. The magnetic field is configured to vary with position in a known way; hence, by virtue of the aforesaid proportionality, the resonance frequency varies with position in a known way. In other words, position is encoded as resonance frequency. MRI using magnetic fields weaker than those of conventional MRI offers several advantages, including cheaper and smaller equipment, greater compatibility with metallic objects, and higher image quality because of low susceptibility distortion and enhanced spin-lattice-relaxation- time contrast. SQUID MRI is being developed into a practical MRI method for applied magnetic flux densities of the order of only 100 T

  13. Pocket atlas of cranial magnetic resonance imaging

    SciTech Connect

    Haughton, V.M.; Daniels, D.L.

    1986-01-01

    This atlas illustrates normal cerebral anatomy in magnetic resonance images. From their studies in cerebral anatomy utilizing cryomicrotome and other techniques, the authors selected more than 100 high-resolution images that represent the most clinically useful scans.

  14. Chronic liver disease: evaluation by magnetic resonance

    SciTech Connect

    Stark, D.D.; Goldberg, H.I.; Moss, A.A.; Bass, N.M.

    1984-01-01

    Magnetic resonance (MR) imaging distinguished hepatitis from fatty liver and cirrhosis in a woman with a history of alcohol abuse. Anatomic and physiologic manifestations of portal hypertension were also demonstrated by MR.

  15. Your Radiologist Explains Magnetic Resonance Angiography (MRA)

    MedlinePlus Videos and Cool Tools

    ... talk with you about magnetic resonance angiography, or as it’s commonly known, MRA. MRA is a noninvasive ... possibility that you’re pregnant tell your doctor as well. On the day of your exam, it’s ...

  16. International Society for Magnetic Resonance in Medicine

    MedlinePlus

    ... Upcoming Workshops & Deadlines Past Workshops Endorsed Meetings & Education International Outreach Event Planning Guides Education MR Safety Resources ... Center E-Library Virtual Meetings Connect With Us International Society for Magnetic Resonance in Medicine 2300 Clayton ...

  17. Coronary Computed Tomography and Magnetic Resonance Imaging

    PubMed Central

    Kantor, Birgit; Nagel, Eike; Schoenhagen, Paul; Barkhausen, Jörg; Gerber, Thomas C.

    2009-01-01

    Cardiac computed tomography and magnetic resonance are relatively new imaging modalities that can exceed the ability of established imaging modalities to detect present pathology or predict patient outcomes. Coronary calcium scoring may be useful in asymptomatic patients at intermediate risk. Computed tomographic coronary angiography is a first-line indication to evaluate congenitally abnormal coronary arteries and, along with stress magnetic resonance myocardial perfusion imaging, is useful in symptomatic patients with nondiagnostic conventional stress tests. Cardiac magnetic resonance is indicated for visualizing cardiac structure and function, and delayed enhancement magnetic resonance is a first-line indication for assessing myocardial viability. Imaging plaque and molecular mechanisms related to plaque rupture holds great promise for the presymptomatic detection of patients at risk for coronary events but is not yet suitable for routine clinical use. PMID:19269527

  18. Torque-mixing Magnetic Resonance Spectroscopy

    NASA Astrophysics Data System (ADS)

    Losby, Joseph; Fani Sani, Fatemeh; Grandmont, Dylan; Diao, Zhu; Belov, Miro; Burgess, Jacob; Compton, Shawn; Hiebert, Wayne; Vick, Doug; Mohammad, Kaveh; Salimi, Elham; Bridges, Gregory; Thomson, Douglas; Freeman, Mark

    A universal, mechanical torque method for magnetic resonance spectroscopy is presented. In analogy to resonance detection by induction, a signal proportional to the transverse component of a precessing dipole moment can be measured as a pure mechanical torque in broadband, frequency-swept spectroscopy. Comprehensive electron spin resonance of a single-crystal, mesoscopic yttrium iron garnet disk at room temperature are presented to demonstrate the method. The rich detail allows analysis of even complex 3D spin textures.

  19. Children's (Pediatric) Magnetic Resonance Imaging

    MedlinePlus

    ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the inside of ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  20. Magnetic Resonance Imaging (MRI) - Spine

    MedlinePlus

    ... uses radio waves, a magnetic field and a computer to produce detailed pictures of the spine and ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  1. Trapped Ion Magnetic Resonance: Concepts and Designs

    NASA Astrophysics Data System (ADS)

    Pizarro, Pedro Jose

    A novel spectroscopy of trapped ions is proposed which will bring single-ion detection sensitivity to the observation of magnetic resonance spectra and resolve the apparent incompatibility in existing techniques between high information content and high sensitivity. Methods for studying both electron spin resonance (ESR) and nuclear magnetic resonance (NMR) are designed. They assume established techniques for trapping ions in high magnetic field and observing electrically the trapping frequencies with high resolution (<1 Hz) and sensitivity (single -ion). A magnetic bottle field gradient couples the spin and spatial motions together and leads to the small spin -dependent force on the ion exploited by Dehmelt to observe directly the perturbation of the ground-state electron's axial frequency by its spin magnetic moment. A series of fundamental innovations is described to extend magnetic resonance to molecular ions ( cong 100 amu) and nuclear magnetic moments. It is demonstrated how time-domain trapping frequency observations before and after magnetic resonance can be used to make cooling of the particle to its ground state unnecessary. Adiabatic cycling of the magnetic bottle off between detection periods is shown to be practical and to allow high-resolution magnetic resonance to be encoded pointwise as the presence or absence of trapping frequency shifts. Methods of inducing spin -dependent work on the ion orbits with magnetic field gradients and Larmor frequency irradiation are proposed which greatly amplify the attainable shifts in trapping frequency. The first proposal presented builds on Dehmelt's experiment to reveal ESR spectra. A more powerful technique for ESR is then designed where axially synchronized spin transitions perform spin-dependent work in the presence of a magnetic bottle, which also converts axial amplitude changes into cyclotron frequency shifts. The most general approach presented is a continuous Stern-Gerlach effect in which a magnetic field

  2. Designing dielectric resonators on substrates: combining magnetic and electric resonances.

    PubMed

    van de Groep, J; Polman, A

    2013-11-01

    High-performance integrated optics, solar cells, and sensors require nanoscale optical components at the surface of the device, in order to manipulate, redirect and concentrate light. High-index dielectric resonators provide the possibility to do this efficiently with low absorption losses. The resonances supported by dielectric resonators are both magnetic and electric in nature. Combined scattering from these two can be used for directional scattering. Most applications require strong coupling between the particles and the substrate in order to enhance the absorption in the substrate. However, the coupling with the substrate strongly influences the resonant behavior of the particles. Here, we systematically study the influence of particle geometry and dielectric environment on the resonant behavior of dielectric resonators in the visible to near-IR spectral range. We show the key role of retardation in the excitation of the magnetic dipole (MD) mode, as well as the limit where no MD mode is supported. Furthermore, we study the influence of particle diameter, shape and substrate index on the spectral position, width and overlap of the electric dipole (ED) and MD modes. Also, we show that the ED and MD mode can selectively be enhanced or suppressed using multi-layer substrates. And, by comparing dipole excitation and plane wave excitation, we study the influence of driving field on the scattering properties. Finally, we show that the directional radiation profiles of the ED and MD modes in resonators on a substrate are similar to those of point-dipoles close to a substrate. Altogether, this work is a guideline how to tune magnetic and electric resonances for specific applications. PMID:24216852

  3. Investigation of laser polarized xenon magnetic resonance

    NASA Technical Reports Server (NTRS)

    Walsworth, Ronald L.

    1998-01-01

    Ground-based investigations of a new biomedical diagnostic technology: nuclear magnetic resonance of laser polarized noble gas are addressed. The specific research tasks discussed are: (1) Development of a large-scale noble gas polarization system; (2) biomedical investigations using laser polarized noble gas in conventional (high magnetic field) NMR systems; and (3) the development and application of a low magnetic field system for laser polarized noble gas NMR.

  4. Nuclear Magnetic Resonance Technology for Medical Studies

    NASA Astrophysics Data System (ADS)

    Budinger, Thomas F.; Lauterbur, Paul C.

    1984-10-01

    Nuclear magnetic resonance proton imaging provides anatomical definition of normal and abnormal tissues with a contrast and detection sensitivity superior to those of x-ray computed tomography in the human head and pelvis and parts of the cardiovascular and musculoskeletal systems. Recent improvements in technology should lead to advances in diagnostic imaging of the breast and regions of the abdomen. Selected-region nuclear magnetic resonance spectroscopy of protons, carbon-13, and phosphorus-31 has developed into a basic science tool for in vivo studies on man and a unique tool for clinical diagnoses of metabolic disorders. At present, nuclear magnetic resonance is considered safe if access to the magnet environment is controlled. Technological advances employing field strengths over 2 teslas will require biophysical studies of heating and static field effects.

  5. Low-temperature magnetic resonance force microscopy

    NASA Astrophysics Data System (ADS)

    Wago, Koichi

    Magnetic resonance force microscopy (MRFM) is a technique whose goal is to combine the three-dimensional, chemically specific imaging capability of magnetic resonance imaging with the atomic-scale spatial resolution of scanning force microscopy. MRFM relies on the detection of small oscillatory magnetic forces between spins in the sample and a magnetic tip, using a micromechanical cantilever. The force resolution is a key issue for successfully operating MRFM experiments. Operating at low temperature improves the force resolution because of the reduced thermal energy and increased mechanical Q of the cantilever. The spin polarization is also enhanced at low temperature, leading to the improved magnetic resonance sensitivity for ensemble spin samples. A low-temperature magnetic resonance force detection apparatus was built and used to demonstrate a force resolution of 8×10sp{-17}\\ N/sqrt{Hz} at 6 K with a commercial single-crystal silicon cantilever. Both nuclear magnetic resonance (NMR) and electron paramagnetic resonance (EPR) were detected in micron-size samples. Force-detection technique was also applied to a wide range of magnetic resonance measurements, including inversion recovery, nutation, and spin echoes. Force-detected EPR spectra of phosphorus-doped silicon revealed hyperfine splitting, illustrating the possibility of using the MRFM technique for spectroscopic purposes. An improved low-temperature magnetic resonance force microscope was also built, incorporating a magnetic tip mounted directly on the cantilever. This allows a much wider variety of samples to be investigated and greatly improves the convenience of the technique. Using the improved microscope, three-dimensional EPR imaging of diphenylpicrylhydrazil (DPPH) particles was accomplished by scanning the sample in two dimensions while stepping an external field. The EPR force map showed a broad response reflecting the size and shape of the sample, allowing a three-dimensional real

  6. Cyclotron resonance in an inhomogeneous magnetic field

    SciTech Connect

    Albert, J.M. )

    1993-08-01

    Relativistic test particles interacting with a small monochromatic electromagnetic wave are studied in the presence of an inhomogeneous background magnetic field. A resonance-averaged Hamiltonian is derived which retains the effects of passage through resonance. Two distinct regimes are found. In the strongly inhomogeneous case, the resonant phase angle at successive resonances is random, and multiple resonant interactions lead to a random walk in phase space. In the other, adiabatic limit, the phase angle is determined by the phase portrait of the Hamiltonian and leads to a systematic change in the appropriate canonical action (and therefore in the energy and pitch angle), so that the cumulative effect increases directly with the number of resonances.

  7. Magnetic material arrangement in oriented termites: a magnetic resonance study

    NASA Astrophysics Data System (ADS)

    Alves, O. C.; Wajnberg, E.; de Oliveira, J. F.; Esquivel, D. M. S.

    2004-06-01

    Temperature dependence of the magnetic resonance is used to study the magnetic material in oriented Neocapritermes opacus (N.o.) termite, the only prey of the migratory ant Pachycondyla marginata (P.m.). A broad line in the g=2 region, associated to isolated nanoparticles shows that at least 97% of the magnetic material is in the termite's body (abdomen + thorax). From the temperature dependence of the resonant field and from the spectral linewidths, we estimate the existence of magnetic nanoparticles 18.5 ± 0.3 nm in diameter and an effective magnetic anisotropy constant, Keff between 2.1 and 3.2 × 10 4 erg/cm 3. A sudden change in the double integrated spectra at about 100 K for N.o. with the long body axis oriented perpendicular to the magnetic field can be attributed to the Verwey transition, and suggests an organized film-like particle system.

  8. Magnetic resonance imaging by using nano-magnetic particles

    NASA Astrophysics Data System (ADS)

    Shokrollahi, H.; Khorramdin, A.; Isapour, Gh.

    2014-11-01

    Magnetism and magnetic materials play a major role in various biological applications, such as magnetic bioseparation, magnetic resonance imaging (MRI), hyperthermia treatment of cancer and drug delivery. Among these techniques, MRI is a powerful method not only for diagnostic radiology but also for therapeutic medicine that utilizes a magnetic field and radio waves. Recently, this technique has contributed greatly to the promotion of the human quality life. Thus, this paper presents a short review of the physical principles and recent advances of MRI, as well as providing a summary of the synthesis methods and properties of contrast agents, like different core materials and surfactants.

  9. Magnetic plasmonic Fano resonance at optical frequency.

    PubMed

    Bao, Yanjun; Hu, Zhijian; Li, Ziwei; Zhu, Xing; Fang, Zheyu

    2015-05-13

    Plasmonic Fano resonances are typically understood and investigated assuming electrical mode hybridization. Here we demonstrate that a purely magnetic plasmon Fano resonance can be realized at optical frequency with Au split ring hexamer nanostructure excited by an azimuthally polarized incident light. Collective magnetic plasmon modes induced by the circular electric field within the hexamer and each of the split ring can be controlled and effectively hybridized by designing the size and orientation of each ring unit. With simulated results reproducing the experiment, our suggested configuration with narrow line-shape magnetic Fano resonance has significant potential applications in low-loss sensing and may serves as suitable elementary building blocks for optical metamaterials. PMID:25594885

  10. Magnetic resonance imaging of the body

    SciTech Connect

    Higgins, C.B.; Hricak, H.

    1987-01-01

    This text provides reference to magnetic resonance imaging (MRI) of the body. Beginning with explanatory chapters on the physics, instrumentation, and interpretation of MRI, it proceeds to the normal anatomy of the neck, thorax, abdomen, and pelvis. Other chapters cover magnetic resonance imaging of blood flow, the larynx, the lymph nodes, and the spine, as well as MRI in obstetrics. The text features detailed coverage of magnetic resonance imaging of numerous disorders and disease states, including neck disease, thoracic disease; breast disease; congenital and acquired heart disease; vascular disease; diseases of the liver, pancreas, and spleen; diseases of the kidney, adrenals, and retroperitoneum; diseases of the male and female pelvis; and musculoskeletal diseases. Chapters on the biological and environmental hazards of MRI, the current clinical status of MRI in comparison to other imaging modalities, and economic considerations are also included.

  11. The Diversity of Nuclear Magnetic Resonance Spectroscopy

    NASA Astrophysics Data System (ADS)

    Liu, Corey W.; Alekseyev, Viktor Y.; Allwardt, Jeffrey R.; Bankovich, Alexander J.; Cade-Menun, Barbara J.; Davis, Ronald W.; Du, Lin-Shu; Garcia, K. Christopher; Herschlag, Daniel; Khosla, Chaitan; Kraut, Daniel A.; Li, Qing; Null, Brian; Puglisi, Joseph D.; Sigala, Paul A.; Stebbins, Jonathan F.; Varani, Luca

    The discovery of the physical phenomenon of Nuclear Magnetic Resonance (NMR) in 1946 gave rise to the spectroscopic technique that has become a remarkably versatile research tool. One could oversimplify NMR spectros-copy by categorizing it into the two broad applications of structure elucidation of molecules (associated with chemistry and biology) and imaging (associated with medicine). But, this certainly does not do NMR spectroscopy justice in demonstrating its general acceptance and utilization across the sciences. This manuscript is not an effort to present an exhaustive, or even partial review of NMR spectroscopy applications, but rather to provide a glimpse at the wide-ranging uses of NMR spectroscopy found within the confines of a single magnetic resonance research facility, the Stanford Magnetic Resonance Laboratory. Included here are summaries of projects involving protein structure determination, mapping of intermolecular interactions, exploring fundamental biological mechanisms, following compound cycling in the environmental, analysis of synthetic solid compounds, and microimaging of a model organism.

  12. Tutte polynomial in functional magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    García-Castillón, Marlly V.

    2015-09-01

    Methods of graph theory are applied to the processing of functional magnetic resonance images. Specifically the Tutte polynomial is used to analyze such kind of images. Functional Magnetic Resonance Imaging provide us connectivity networks in the brain which are represented by graphs and the Tutte polynomial will be applied. The problem of computing the Tutte polynomial for a given graph is #P-hard even for planar graphs. For a practical application the maple packages "GraphTheory" and "SpecialGraphs" will be used. We will consider certain diagram which is depicting functional connectivity, specifically between frontal and posterior areas, in autism during an inferential text comprehension task. The Tutte polynomial for the resulting neural networks will be computed and some numerical invariants for such network will be obtained. Our results show that the Tutte polynomial is a powerful tool to analyze and characterize the networks obtained from functional magnetic resonance imaging.

  13. Magnetic resonance of magnetic fluid and magnetoliposome preparations

    NASA Astrophysics Data System (ADS)

    Morais, Paulo C.; Santos, Judes G.; Skeff Neto, K.; Pelegrini, Fernando; De Cuyper, Marcel

    2005-05-01

    In this study, magnetic resonance was used to investigate lauric acid-coated magnetite-based magnetic fluid particles and particles which are surrounded by a double layer of phospholipid molecules (magnetoliposomes). The data reveal the presence of monomers and dimers in both samples. Whereas evidence for a thermally induced disruption of dimers is found in the magnetic fluid, apparently, the bilayer phospholipid envelop prevents the dissociation in the magnetoliposome samples.

  14. Magnetic resonance signal moment determination using the Earth's magnetic field.

    PubMed

    Fridjonsson, E O; Creber, S A; Vrouwenvelder, J S; Johns, M L

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system. PMID:25700116

  15. Magnetic resonance signal moment determination using the Earth's magnetic field

    NASA Astrophysics Data System (ADS)

    Fridjonsson, E. O.; Creber, S. A.; Vrouwenvelder, J. S.; Johns, M. L.

    2015-03-01

    We demonstrate a method to manipulate magnetic resonance data such that the moments of the signal spatial distribution are readily accessible. Usually, magnetic resonance imaging relies on data acquired in so-called k-space which is subsequently Fourier transformed to render an image. Here, via analysis of the complex signal in the vicinity of the centre of k-space we are able to access the first three moments of the signal spatial distribution, ultimately in multiple directions. This is demonstrated for biofouling of a reverse osmosis (RO) membrane module, rendering unique information and an early warning of the onset of fouling. The analysis is particularly applicable for the use of mobile magnetic resonance spectrometers; here we demonstrate it using an Earth's magnetic field system.

  16. Nanomagnetic planar magnetic resonance microscopy "lens".

    PubMed

    Barbic, Mladen; Scherer, Axel

    2005-04-01

    The achievement of three-dimensional atomic resolution magnetic resonance microscopy remains one of the main challenges in the visualization of biological molecules. The prospects for single spin microscopy have come tantalizingly close due to the recent developments in sensitive instrumentation. Despite the single spin detection capability in systems of spatially well-isolated spins, the challenge that remains is the creation of conditions in space where only a single spin is resonant and detected in the presence of other spins in its natural dense spin environment. We present a nanomagnetic planar design where a localized Angstrom-scale point in three-dimensional space is created above the nanostructure with a nonzero minimum of the magnetic field magnitude. The design thereby represents a magnetic resonance microscopy "lens" where potentially only a single spin located in the "focus" spot of the structure is resonant. Despite the presence of other spins in the Angstrom-scale vicinity of the resonant spin, the high gradient magnetic field of the "lens" renders those spins inactive in the detection process. PMID:15826129

  17. Magnetic resonance neurography of the brachial plexus

    PubMed Central

    Upadhyaya, Vaishali; Upadhyaya, Divya Narain; Kumar, Adarsh; Pandey, Ashok Kumar; Gujral, Ratni; Singh, Arun Kumar

    2015-01-01

    Magnetic Resonance Imaging (MRI) is being increasingly recognised all over the world as the imaging modality of choice for brachial plexus and peripheral nerve lesions. Recent refinements in MRI protocols have helped in imaging nerve tissue with greater clarity thereby helping in the identification, localisation and classification of nerve lesions with greater confidence than was possible till now. This article on Magnetic Resonance Neurography (MRN) is based on the authors’ experience of imaging the brachial plexus and peripheral nerves using these protocols over the last several years. PMID:26424974

  18. Granular convection observed by magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Ehrichs, E. E.; Jaeger, H. M.; Karczmar, Greg S.; Knight, James B.; Kuperman, Vadim Yu.; Nagel, Sidney R.

    1995-03-01

    Vibrations in a granular material can spontaneously produce convection rolls reminiscent of those seen in fluids. Magnetic resonance imaging provides a sensitive and noninvasive probe for the detection of these convection currents, which have otherwise been difficult to observe. A magnetic resonance imaging study of convection in a column of poppy seeds yielded data about the detailed shape of the convection rolls and the depth dependence of the convection velocity. The velocity was found to decrease exponentially with depth; a simple model for this behavior is presented here.

  19. Granular convection observed by magnetic resonance imaging

    SciTech Connect

    Ehrichs, E.E.; Jaeger, H.M.; Knight, J.B.; Nagel, S.R.; Karczmar, G.S.; Kuperman, V.Yu.

    1995-03-17

    Vibrations in a granular material can spontaneously produce convection rolls reminiscent of those seen in fluids. Magnetic resonance imaging provides a sensitive and noninvasive probe for the detection of these convection currents, which have otherwise been difficult to observe. A magnetic resonance imaging study of convection in a column of poppy seeds yielded data about the detailed shape of the convection rolls and the depth dependence of the convection velocity. The velocity was found to decrease exponentially with depth; a simple model for this behavior is presented here. 31 refs., 4 figs.

  20. Artifacts in Breast Magnetic Resonance Imaging.

    PubMed

    Anthony, Marina-Portia; Nguyen, Dustin; Friedlander, Lauren; Mango, Victoria; Wynn, Ralph; Ha, Richard

    2016-01-01

    As breast magnetic resonance imaging has evolved to become a routine part of clinical practice, so too has the need for radiologists to be aware of its potential pitfalls and limitations. Unique challenges arise in the identification and remedy of artifacts in breast magnetic resonance imaging, and it is important that radiologists and technicians work together to optimize protocols and monitor examinations such that these may be minimized or avoided entirely. This article presents patient-related and technical artifacts that may give rise to reduced image quality and ways to recognize and reduce them. PMID:26343534

  1. Magnetic force microscopy using tip magnetization modulated by ferromagnetic resonance

    NASA Astrophysics Data System (ADS)

    Arima, Eiji; Naitoh, Yoshitaka; Li, Yan Jun; Yoshimura, Satoru; Saito, Hitoshi; Nomura, Hikaru; Nakatani, Ryoichi; Sugawara, Yasuhiro

    2015-03-01

    In magnetic force microscopy (MFM), the tip-sample distance should be reduced to analyze the microscopic magnetic domain structure with high spatial resolution. However, achieving a small tip-sample distance has been difficult because of superimposition of interaction forces such as van der Waals and electrostatic forces induced by the sample surface. In this study, we propose a new method of MFM using ferromagnetic resonance (FMR) to extract only the magnetic field near the sample surface. In this method, the magnetization of a magnetic cantilever is modulated by FMR to separate the magnetic field and topographic structure. We demonstrate the modulation of the magnetization of the cantilever and the identification of the polarities of a perpendicular magnetic medium.

  2. Magnetic force microscopy using tip magnetization modulated by ferromagnetic resonance.

    PubMed

    Arima, Eiji; Naitoh, Yoshitaka; Li, Yan Jun; Yoshimura, Satoru; Saito, Hitoshi; Nomura, Hikaru; Nakatani, Ryoichi; Sugawara, Yasuhiro

    2015-03-27

    In magnetic force microscopy (MFM), the tip-sample distance should be reduced to analyze the microscopic magnetic domain structure with high spatial resolution. However, achieving a small tip-sample distance has been difficult because of superimposition of interaction forces such as van der Waals and electrostatic forces induced by the sample surface. In this study, we propose a new method of MFM using ferromagnetic resonance (FMR) to extract only the magnetic field near the sample surface. In this method, the magnetization of a magnetic cantilever is modulated by FMR to separate the magnetic field and topographic structure. We demonstrate the modulation of the magnetization of the cantilever and the identification of the polarities of a perpendicular magnetic medium. PMID:25736463

  3. Magnetic elliptical polarization of Schumann resonances

    SciTech Connect

    Sentman, D.D.

    1987-08-01

    Measurements of orthogonal, horizontal components of the magnetic field in the ELF range obtained during September 1985 show that the Schumann resonance eigenfrequencies determined separately for the north-south and east-west magnetic components differ by as much as 0.5 Hz, suggesting that the underlying magnetic signal is not linearly polarized at such times. The high degree of magnetic ellipticity found suggests that the side multiplets of the Schumann resonances corresponding to azimuthally inhomogeneous normal modes are strongly excited in the highly asymmetric earth-ionosphere cavity. The dominant sense of polarization over the measurement passband is found to be right-handed during local daylight hours, and to be left-handed during local nighttime hours. 16 references.

  4. Magnetic elliptical polarization of Schumann resonances

    NASA Technical Reports Server (NTRS)

    Sentman, D. D.

    1987-01-01

    Measurements of orthogonal, horizontal components of the magnetic field in the ELF range obtained during September 1985 show that the Schumann resonance eigenfrequencies determined separately for the north-south and east-west magnetic components differ by as much as 0.5 Hz, suggesting that the underlying magnetic signal is not linearly polarized at such times. The high degree of magnetic ellipticity found suggests that the side multiplets of the Schumann resonances corresponding to azimuthally inhomogeneous normal modes are strongly excited in the highly asymmetric earth-ionosphere cavity. The dominant sense of polarization over the measurement passband is found to be right-handed during local daylight hours, and to be left-handed during local nighttime hours.

  5. Spin connection resonance in magnetic motors

    NASA Astrophysics Data System (ADS)

    Evans, Myron W.; Eckardt, H.

    2007-11-01

    A mechanism is proposed for rotation of magnetic assemblies by a torque consisting of the magnetic dipole moment of the assembly and a magnetic field generated from space-time in Einstein-Cartan-Evans (ECE) field theory. It is shown that when the magnetic assembly is stationary, the space-time is described by a Helmholtz wave equation in the tetrad as eigenfunction. This is a balance condition in which the Cartan torsion of the space-time is zero, but in which the tetrad and spin connection are non-zero. This balance may be broken by a driving current density produced by the magnetic assembly. The Helmholtz equation becomes an undamped oscillator equation. At resonance the torque on the magnetic assembly may be amplified sufficiently to cause the whole assembly to rotate, as observed experimentally in a repeatable and reproducible manner.

  6. Enhancement of artificial magnetism via resonant bianisotropy

    PubMed Central

    Markovich, Dmitry; Baryshnikova, Kseniia; Shalin, Alexander; Samusev, Anton; Krasnok, Alexander; Belov, Pavel; Ginzburg, Pavel

    2016-01-01

    All-dielectric “magnetic light” nanophotonics based on high refractive index nanoparticles allows controlling magnetic component of light at nanoscale without having high dissipative losses. The artificial magnetic optical response of such nanoparticles originates from circular displacement currents excited inside those structures and strongly depends on geometry and dispersion of optical materials. Here an approach for enhancing of magnetic response via resonant bianisotropy effect is proposed and analyzed. The key mechanism of enhancement is based on electric-magnetic interaction between two electrically and magnetically resonant nanoparticles of all-dielectric dimer. It was shown that proper geometrical arrangement of the dimer in respect to the incident illumination direction allows flexible control over all vectorial components of the magnetic moment, tailoring the latter in the dynamical range of 100% and delivering enhancement up to 36% relative to performances of standalone spherical particles. The proposed approach provides pathways for designs of all-dielectric metamaterials and metasurfaces with strong magnetic responses. PMID:26941126

  7. Brain Morphometry Using Anatomical Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Bansal, Ravi; Gerber, Andrew J.; Peterson, Bradley S.

    2008-01-01

    The efficacy of anatomical magnetic resonance imaging (MRI) in studying the morphological features of various regions of the brain is described, also providing the steps used in the processing and studying of the images. The ability to correlate these features with several clinical and psychological measures can help in using anatomical MRI to…

  8. Sports Health Magnetic Resonance Imaging Challenge

    PubMed Central

    Howell, Gary A.; Stadnick, Michael E.; Awh, Mark H.

    2010-01-01

    Injuries to the Lisfranc ligament complex are often suspected, particularly in the setting of midfoot pain without radiographic abnormality. Knowledge of the anatomy and magnetic resonance imaging findings of injuries to this region is helpful for the diagnosing and treating physicians. PMID:23015984

  9. An improved nuclear magnetic resonance spectrometer

    NASA Technical Reports Server (NTRS)

    Elleman, D. D.; Manatt, S. L.

    1967-01-01

    Cylindrical sample container provides a high degree of nuclear stabilization to a nuclear magnetic resonance /nmr/ spectrometer. It is placed coaxially about the nmr insert and contains reference sample that gives a signal suitable for locking the field and frequency of an nmr spectrometer with a simple audio modulation system.

  10. Nuclear Magnetic Resonance Technology for Medical Studies.

    ERIC Educational Resources Information Center

    Budinger, Thomas F.; Lauterbur, Paul C.

    1984-01-01

    Reports on the status of nuclear magnetic resonance (NMR) from theoretical and clinical perspectives, reviewing NMR theory and relaxation parameters relevant to NMR imaging. Also reviews literature related to modern imaging strategies, signal-to-noise ratio, contrast agents, in vivo spectroscopy, spectroscopic imaging, clinical applications, and…

  11. Imaging Intelligence with Proton Magnetic Resonance Spectroscopy

    ERIC Educational Resources Information Center

    Jung, Rex E.; Gasparovic, Charles; Chavez, Robert S.; Caprihan, Arvind; Barrow, Ranee; Yeo, Ronald A.

    2009-01-01

    Proton magnetic resonance spectroscopy ([to the first power]H-MRS) is a technique for the assay of brain neurochemistry "in vivo." N-acetylaspartate (NAA), the most prominent metabolite visible within the [to the first power]H-MRS spectrum, is found primarily within neurons. The current study was designed to further elucidate NAA-cognition…

  12. Use of Magnetic Resonance in Pancreaticobiliary Emergencies.

    PubMed

    Bates, David D B; LeBedis, Christina A; Soto, Jorge A; Gupta, Avneesh

    2016-05-01

    This article presents the magnetic resonance protocols, imaging features, diagnostic criteria, and complications of commonly encountered emergencies in pancreaticobiliary imaging. Pancreatic trauma, bile leak, acute cholecystitis, biliary obstruction, and pancreatitis are discussed. Various classifications and complications that can arise with these conditions, as well as artifacts that may mimic pathology, are also included. PMID:27150328

  13. Magnetic resonance investigation of magnetic-labeled baker's yeast cells

    NASA Astrophysics Data System (ADS)

    Godoy Morais, J. P. M.; Azevedo, R. B.; Silva, L. P.; Lacava, Z. G. M.; Báo, S. N.; Silva, O.; Pelegrini, F.; Gansau, C.; Buske, N.; Safarik, I.; Safarikova, M.; Morais, P. C.

    2004-05-01

    In this study, the interaction of DMSA-coated magnetite nanoparticles (5 and 10 nm core-size) with Saccharomyces cerevisae was investigated using magnetic resonance (MR) and transmission electron microscopy (TEM). The TEM micrographs revealed magnetite nanoparticles attached externally to the cell wall. The MR data support the strong interaction among the nanoparticles supported by the cells. A remarkable shift in the resonance field was used as signature of particle attachment to the cell wall.

  14. Nuclear magnetic resonance properties of lunar samples.

    NASA Technical Reports Server (NTRS)

    Kline, D.; Weeks, R. A.

    1972-01-01

    Nuclear magnetic resonance spectra of Na-23, Al-27, and P-31 in fines samples 10084,60 and 14163,168 and in crystalline rock samples 12021,55 and 14321,166, have been recorded over a range of frequencies up to 20 MHz. A shift in the field at which maximum absorption occurs for all of the spectra relative to the field at which maximum absorption occurs for terrestrial analogues is attributed to a sample-dependent magnetic field at the Na, Al, and P sites opposing the laboratory field. The magnitude of these fields internal to the samples is sample dependent and varies from 5 to 10 G. These fields do not correlate with the iron content of the samples. However, the presence of single-domain particles of iron distributed throughout the plagioclase fraction that contains the principal fraction of Na and Al is inferred from electron magnetic resonance spectra shapes.

  15. Magnetic Earth Ionosphere Resonant Frequencies

    NASA Technical Reports Server (NTRS)

    Spaniol, Craig

    1994-01-01

    The Community College Division is pleased to report progress of NASA funded research at West Virginia State College. During this reporting period, the project research group has continued with activities to develop instrumentation capability designed to monitor resonant cavity frequencies in the atmospheric region between the Earth's surface and the ionosphere. In addition, the project's principal investigator, Dr. Craig Spaniol, and NASA technical officer, Dr. John Sutton, have written and published technical papers intended to expand the scientific and technical framework needed for project research. This research continues to provide an excellent example of government and education working together to provide significant research in the college environment. This cooperative effort has provided many students with technical project work which compliments their education.

  16. Volume coil based on hybridized resonators for magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Jouvaud, C.; Abdeddaim, R.; Larrat, B.; de Rosny, J.

    2016-01-01

    We present an electromagnetic device based on hybridization of four half-wavelength dipoles which increases the uniformity and the strength of the radio-frequency (RF) field of a Magnetic Resonant Imaging (MRI) apparatus. Numerical results show that this Hybridized Coil (HC) excited with a classical loop coil takes advantage of the magnetic hybrid modes. The distribution of the RF magnetic field is experimentally confirmed on a 7-T MRI with a gelatin phantom. Finally, the HC is validated in vivo by imaging the head of an anesthetized rat. We measure an overall increase of the signal to noise ratio with up to 2.4 fold increase in regions of interest far from the active loop coil.

  17. Magnetic resonance of calcified tissues

    NASA Astrophysics Data System (ADS)

    Wehrli, Felix W.

    2013-04-01

    MRI of the human body is largely made possible by the favorable relaxation properties of protons of water and triacyl glycerides prevalent in soft tissues. Hard tissues - key among them bone - are generally less amenable to measurement with in vivo MR imaging techniques, not so much as a result of the lower proton density but rather due to the extremely short life-times of the proton signal in water bound to solid-like entities, typically collagen, or being trapped in micro-pores. Either mechanism can enhance T2 relaxation by up to three orders of magnitude relative to their soft-tissue counterparts. Detection of these protons requires solid-state techniques that have emerged in recent years and that promise to add a new dimension to the study of hard tissues. Alternative approaches to probe calcified tissues exploit their characteristic magnetic properties. Bone, teeth and extra-osseous calcium-containing biomaterials are unique in that they are more diamagnetic than all other tissues and thus yield information indirectly by virtue of the induced magnetic fields present in their vicinity. Progress has also been made in methods allowing very high-resolution structural imaging of trabecular and cortical bone relying on detection of the surrounding soft-tissues. This brief review, much of it drawn from work conducted in the author's laboratory, seeks to highlight opportunities with focus on early-stage developments for image-based assessment of structure, function, physiology and mechanics of calcified tissues in humans via liquid and solid-state approaches, including proton, deuteron and phosphorus NMR and MRI.

  18. Peridotite xenoliths from the Polynesian Austral and Samoa hotspots: Implications for the destruction of ancient 187Os and 142Nd isotopic domains and the preservation of Hadean 129Xe in the modern convecting mantle

    NASA Astrophysics Data System (ADS)

    Jackson, M. G.; Shirey, S. B.; Hauri, E. H.; Kurz, M. D.; Rizo, H.

    2016-07-01

    The Re-Os systematics in 13 peridotite xenoliths hosted in young (<0.39 myr) rejuvenated lavas from the Samoan island of Savai'i and 8 peridotite xenoliths from 6 to 10 myr old lavas from the Austral island of Tubuai have been examined to evaluate the history of the oceanic mantle in this region. Modal mineralogy, trace element compositions and 187Os/188Os ratios suggest that these peridotites are not cognate or residual to mantle plumes but rather samples of Pacific oceanic lithosphere created at the ridge. Savai'i and Tubuai islands lie along a flow line in the Pacific plate, and provide two snapshots (separated by over 40 Ma in time) of Pacific mantle that originated in the same region of the East Pacific rise. Tubuai xenoliths exhibit 187Os/188Os from 0.1163 to 0.1304, and Savai'i (Samoa) xenoliths span a smaller range from 0.1173 to 0.1284. The 187Os/188Os ratios measured in Tubuai xenoliths are lower than (and show no overlap with) basalts from Tubuai. The 187Os/188Os of the Savai'i xenoliths overlap the isotopic compositions of lavas from the island of Savai'i, but also extend to lower 187Os/188Os than the lavas. 3He/4He measurements of a subset of the xenoliths range from 2.5 to 6.4 Ra for Tubuai and 10.8 to 12.4 Ra for Savai'i. Like abyssal peridotites and xenoliths from oceanic hotspots that sample the convecting mantle, Os isotopes from the Savai'i and Tubuai xenolith suites are relatively unradiogenic, but do not preserve a record of depleted early-formed (Hadean and Archean) mantle domains expected from earlier cycles of ridge-related depletion, continent extraction, or subcontinental lithospheric mantle erosion. The lack of preservation of early-formed, geochemically-depleted Os-isotopic and 142Nd/144Nd domains in the modern convecting mantle contrasts with the preservation of early-formed (early-Hadean) 129Xe/130Xe isotopic heterogeneities in the convecting mantle. This can be explained if the initial isotopic signatures in Re-Os and Sm-Nd systems

  19. Magnetic resonance imaging with an optical atomicmagnetometer

    SciTech Connect

    Xu, Shoujun; Yashchuk, Valeriy V.; Donaldson, Marcus H.; Rochester, Simon M.; Budker, Dmitry; Pines, Alexander

    2006-05-09

    Magnetic resonance imaging (MRI) is a noninvasive andversatile methodology that has been applied in many disciplines1,2. Thedetection sensitivity of conventional Faraday detection of MRI depends onthe strength of the static magnetic field and the sample "fillingfactor." Under circumstances where only low magnetic fields can be used,and for samples with low spin density or filling factor, the conventionaldetection sensitivity is compromised. Alternative detection methods withhigh sensitivity in low magnetic fields are thus required. Here we showthe first use of a laser-based atomic magnetometer for MRI detection inlow fields. Our technique also employs remote detection which physicallyseparates the encoding and detection steps3-5, to improve the fillingfactor of the sample. Potentially inexpensive and using a compactapparatus, our technique provides a novel alternative for MRI detectionwith substantially enhanced sensitivity and time resolution whileavoiding the need for cryogenics.

  20. A hyperpolarized equilibrium for magnetic resonance

    NASA Astrophysics Data System (ADS)

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B.; Mewis, Ryan E.; Highton, Louise A. R.; Kenny, Stephen M.; Green, Gary G. R.; Leibfritz, Dieter; Korvink, Jan G.; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-12-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all 1H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10-3 Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application.

  1. A hyperpolarized equilibrium for magnetic resonance.

    PubMed

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B; Mewis, Ryan E; Highton, Louise A R; Kenny, Stephen M; Green, Gary G R; Leibfritz, Dieter; Korvink, Jan G; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-01-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all ¹H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10⁻³ Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application. PMID:24336292

  2. A hyperpolarized equilibrium for magnetic resonance

    PubMed Central

    Hövener, Jan-Bernd; Schwaderlapp, Niels; Lickert, Thomas; Duckett, Simon B.; Mewis, Ryan E.; Highton, Louise A. R.; Kenny, Stephen M.; Green, Gary G. R.; Leibfritz, Dieter; Korvink, Jan G.; Hennig, Jürgen; von Elverfeldt, Dominik

    2013-01-01

    Nuclear magnetic resonance spectroscopy and imaging (MRI) play an indispensable role in science and healthcare but use only a tiny fraction of their potential. No more than ≈10 p.p.m. of all 1H nuclei are effectively detected in a 3-Tesla clinical MRI system. Thus, a vast array of new applications lays dormant, awaiting improved sensitivity. Here we demonstrate the continuous polarization of small molecules in solution to a level that cannot be achieved in a viable magnet. The magnetization does not decay and is effectively reinitialized within seconds after being measured. This effect depends on the long-lived, entangled spin-order of parahydrogen and an exchange reaction in a low magnetic field of 10−3 Tesla. We demonstrate the potential of this method by fast MRI and envision the catalysis of new applications such as cancer screening or indeed low-field MRI for routine use and remote application. PMID:24336292

  3. Foundations of Advanced Magnetic Resonance Imaging

    PubMed Central

    Bammer, Roland; Skare, Stefan; Newbould, Rexford; Liu, Chunlei; Thijs, Vincent; Ropele, Stefan; Clayton, David B.; Krueger, Gunnar; Moseley, Michael E.; Glover, Gary H.

    2005-01-01

    Summary: During the past decade, major breakthroughs in magnetic resonance imaging (MRI) quality were made by means of quantum leaps in scanner hardware and pulse sequences. Some advanced MRI techniques have truly revolutionized the detection of disease states and MRI can now—within a few minutes—acquire important quantitative information noninvasively from an individual in any plane or volume at comparatively high resolution. This article provides an overview of the most common advanced MRI methods including diffusion MRI, perfusion MRI, functional MRI, and the strengths and weaknesses of MRI at high magnetic field strengths. PMID:15897944

  4. Magnetic resonances in nano-scale metamaterials

    NASA Astrophysics Data System (ADS)

    Hao, Zhao; Liddle, Alex; Martin, Michael

    2006-03-01

    We have designed, fabricated, and optically measured several different kinds of nano-scale metamaterials. We make use e-beam nano-lithography technology at LBNL's Center for X-Ray Optics for fabricating these structures on extremely thin SiN substrates so that they are close to free-standing. Optical properties were measured as a function of incidence angle and polarization. We directly observe a strong magnetic resonance consistent with a negative magnetic permeability in our samples at mid- and near-IR optical frequencies. We will discuss the results in comparison with detailed simulations, and will discuss the electric dipole or quadrupole resonances observed in the samples. Finally, we will report on our progress towards constructing a fully negative index of refraction meta-material.

  5. Proton magnetic resonance spectroscopy in multiple sclerosis

    SciTech Connect

    Wolinsky, J.S.; Narayana, P.A.; Fenstermacher, M.J. )

    1990-11-01

    Regional in vivo proton magnetic resonance spectroscopy provides quantitative data on selected chemical constituents of brain. We imaged 16 volunteers with clinically definite multiple sclerosis on a 1.5 tesla magnetic resonance scanner to define plaque-containing volumes of interest, and obtained localized water-suppressed proton spectra using a stimulated echo sequence. Twenty-five of 40 plaque-containing regions provided spectra of adequate quality. Of these, 8 spectra from 6 subjects were consistent with the presence of cholesterol or fatty acids; the remainder were similar to those obtained from white matter of normal volunteers. This early experience with regional proton spectroscopy suggests that individual plaques are distinct. These differences likely reflect dynamic stages of the evolution of the demyelinative process not previously accessible to in vivo investigation.

  6. Magnetic Resonance Characterization of Ischemic Tissue Metabolism

    PubMed Central

    Cheung, Jerry S; Wang, Xiaoying; Zhe Sun, Phillip

    2011-01-01

    Magnetic resonance imaging (MRI) and spectroscopy (MRS) are versatile diagnostic techniques capable of characterizing the complex stroke pathophysiology, and hold great promise for guiding stroke treatment. Particularly, tissue viability and salvageability are closely associated with its metabolic status. Upon ischemia, ischemic tissue metabolism is disrupted including altered metabolism of glucose and oxygen, elevated lactate production/accumulation, tissue acidification and eventually, adenosine triphosphate (ATP) depletion and energy failure. Whereas metabolism impairment during ischemic stroke is complex, it may be monitored non-invasively with magnetic resonance (MR)-based techniques. Our current article provides a concise overview of stroke pathology, conventional and emerging imaging and spectroscopy techniques, and data analysis tools for characterizing ischemic tissue damage. PMID:22216079

  7. Magnetic resonance angiography: physical principles and applications.

    PubMed

    Kiruluta, Andrew J M; González, R Gilberto

    2016-01-01

    Magnetic resonance angiography (MRA) is the visualization of hemodynamic flow using imaging techniques that discriminate flowing spins in blood from those in stationary tissue. There are two classes of MRA methods based on whether the magnetic resonance imaging signal in flowing blood is derived from the amplitude of the moving spins, the time-of-flight methods, or is based on the phase accumulated by these flowing spins, as in phase contrast methods. Each method has particular advantages and limitations as an angiographic imaging technique, as evidenced in their application space. Here we discuss the physics of MRA for both classes of imaging techniques, including contrast-enhanced approaches and the recent rapid expansion of the techniques to fast acquisition and processing techniques using parallel imaging coils as well as their application in high-field MR systems such as 3T and 7T. PMID:27432663

  8. Combined Confocal and Magnetic Resonance Microscopy

    SciTech Connect

    Wind, Robert A.; Majors, Paul D.; Minard, Kevin R.; Ackerman, Eric J.; Daly, Don S.; Holtom, Gary R.; Thrall, Brian D.; Weber, Thomas J.

    2002-05-12

    Confocal and magnetic resonance microscopy are both used to study live cells in a minimally invasive way. Both techniques provide complementary information. Therefore, by examining cells simultaneously with both methodologies, more detailed information is obtained than is possible with each of the microscopes individually. In this paper two configurations of a combined confocal and magnetic resonance microscope described. In both cases the sample compartment is part of a temperature regulated perfusion system. The first configuration is capable of studying large single cells or three-dimensional cell agglomerates, whereas with the second configuration monolayers of mammalian cells can be investigated . Combined images are shown of Xenopus laevis frog oocytes, model JB6 tumor spheroids, and a single layer of Chinese hamster ovary cells. Finally, potential applications of the combined microscope are discussed.

  9. [Indications for magnetic resonance imaging in pneumology].

    PubMed

    Arrivé, L

    1997-04-19

    Tissue mobilization caused by respiration and heart beat and lower spacial resolution than with computed tomography has limited use of magnetic resonance imaging (MRI) in pneumology. Nevertheless, because of the high-quality of spontaneous contrast and the non irradiation nature of the examination, there are selected indications. For bronchogenic cancer, MRI is reserved for selected cases to evaluate tumor extension. For tumors of the mediastinum, MRI is particularly useful for evaluating extension of neurogenic tumors. MRI also gives a better visualization of processes involving the diaphragm than computed tomography. The development of magnetic resonance angiography is a major progress for exploration of pulmonary embolism as repeated acquisitions can be obtained without injection of a contrast medium. Several studies have shown that MRI visualizes well solitary lung nodules, clearly distinguishing fat content from vascularized nodules. For the pulmonary parenchyma, further advances are necessary before MRI can become a routine exploration technique. PMID:9180867

  10. Antiferromagnetic resonance excitation by terahertz magnetic field resonantly enhanced with split ring resonator

    SciTech Connect

    Mukai, Y.; Hirori, H.; Yamamoto, T.; Kageyama, H.; Tanaka, K.

    2014-07-14

    Excitation of antiferromagnetic resonance (AFMR) in a HoFeO{sub 3} crystal combined with a split ring resonator (SRR) is studied using terahertz (THz) electromagnetic pulses. The magnetic field in the vicinity of the SRR is induced by the incident THz electric field component and excites spin oscillations that correspond to the AFMR, which are directly probed by the Faraday rotation of the polarization of a near-infrared probe pulse. The good agreement of the temperature-dependent magnetization dynamics with the calculation using the two-lattice Landau-Lifshitz-Gilbert equation confirms that the AFMR is excited by the THz magnetic field, which is enhanced at the SRR resonance frequency by a factor of 20 compared to the incident magnetic field.

  11. Fundamental physics of magnetic resonance imaging.

    PubMed

    Villafana, T

    1988-07-01

    Although similar to computerized tomography, in that cross-sectional images are produced, the physical principles underlying magnetic resonance are entirely different. The MRI process, as commonly implemented, involves the excitation of hydrogen nuclei and the analysis of how these nuclei recover to the original equilibrium steady states that they had prior to excitation. This article discusses that process, that is, preparatory alignment, RF excitation, relaxation and signal measurement, and spatial localization. PMID:3380941

  12. Nuclear magnetic resonance in Kondo lattice systems

    NASA Astrophysics Data System (ADS)

    Curro, Nicholas J.

    2016-06-01

    Nuclear magnetic resonance has emerged as a vital tool to explore the fundamental physics of Kondo lattice systems. Because nuclear spins experience two different hyperfine couplings to the itinerant conduction electrons and to the local f moments, the Knight shift can probe multiple types of spin correlations that are not accessible via other techniques. The Knight shift provides direct information about the onset of heavy electron coherence and the emergence of the heavy electron fluid.

  13. Neurosurgical uses for intraprocedural magnetic resonance imaging.

    PubMed

    Mutchnick, Ian S; Moriarty, Thomas M

    2005-10-01

    Neurosurgical procedures demand precision, and efforts to create accurate neurosurgical navigation have been central to the profession through its history. Magnetic resonance image (MRI)-guided navigation offers the possibility of real-time, image-based stereotactic information for the neurosurgeon, which makes possible a number of diagnostic and therapeutic procedures. This article will review both current options for intraoperative MRI operative suite arrangements and the current therapeutic/diagnostic uses of intraoperative MRI. PMID:16924171

  14. Magnetic resonance imaging: Principles and applications

    SciTech Connect

    Kean, D.; Smith, M.

    1986-01-01

    This text covers the physics underlying magnetic resonance (MR) imaging; pulse sequences; image production; equipment; aspects of clinical imaging; and the imaging of the head and neck, thorax, abdomen and pelvis, and musculoskeletal system; and MR imaging. The book provides about 150 examples of MR images that give an overview of the pathologic conditions imaged. There is a discussion of the physics of MR imaging and also on the spin echo.

  15. Magnetic resonance imaging of diabetic foot complications

    PubMed Central

    Low, Keynes TA; Peh, Wilfred CG

    2015-01-01

    This pictorial review aims to illustrate the various manifestations of the diabetic foot on magnetic resonance (MR) imaging. The utility of MR imaging and its imaging features in the diagnosis of pedal osteomyelitis are illustrated. There is often difficulty encountered in distinguishing osteomyelitis from neuroarthropathy, both clinically and on imaging. By providing an accurate diagnosis based on imaging, the radiologist plays a significant role in the management of patients with complications of diabetic foot. PMID:25640096

  16. Magnetic resonance imaging of diabetic foot complications.

    PubMed

    Low, Keynes T A; Peh, Wilfred C G

    2015-01-01

    This pictorial review aims to illustrate the various manifestations of the diabetic foot on magnetic resonance (MR) imaging. The utility of MR imaging and its imaging features in the diagnosis of pedal osteomyelitis are illustrated. There is often difficulty encountered in distinguishing osteomyelitis from neuroarthropathy, both clinically and on imaging. By providing an accurate diagnosis based on imaging, the radiologist plays a significant role in the management of patients with complications of diabetic foot. PMID:25640096

  17. Fluctuating magnetic field induced resonant activation

    SciTech Connect

    Mondal, Shrabani; Das, Sudip; Baura, Alendu; Bag, Bidhan Chandra

    2014-12-14

    In this paper, we have studied the properties of a Brownian particle at stationary state in the presence of a fluctuating magnetic field. Time dependence of the field makes the system thermodynamically open. As a signature of that the steady state distribution function becomes function of damping strength, intensity of fluctuations and constant parts of the applied magnetic field. It also depends on the correlation time of the fluctuating magnetic field. Our another observation is that the random magnetic field can induce the resonant activation phenomenon. Here correlation time is increased under the fixed variance of the fluctuating field. But if the correlation time (τ) increases under the fixed field strength then the mean first passage time rapidly grows at low τ and it almost converges at other limit. This is sharp contrast to the usual colored noise driven open system case where the mean first passage time diverges exponentially. We have also observed that a giant enhancement of barrier crossing rate occurs particularly at large strength of constant parts of the applied magnetic field even for very weak fluctuating magnetic field. Finally, break down of the Arrhenius result and disappearance of the Kramers’ turn over phenomenon may occur in the presence of a fluctuating magnetic field.

  18. Magnetic Resonance Microscopy of Collagen Mineralization

    PubMed Central

    Chesnick, Ingrid E.; Mason, Jeffrey T.; Giuseppetti, Anthony A.; Eidelman, Naomi; Potter, Kimberlee

    2008-01-01

    A model mineralizing system was subjected to magnetic resonance microscopy to investigate how water proton transverse (T2) relaxation times and magnetization transfer ratios can be applied to monitor collagen mineralization. In our model system, a collagen sponge was mineralized with polymer-stabilized amorphous calcium carbonate. The lower hydration and water proton T2 values of collagen sponges during the initial mineralization phase were attributed to the replacement of the water within the collagen fibrils by amorphous calcium carbonate. The significant reduction in T2 values by day 6 (p < 0.001) was attributed to the appearance of mineral crystallites, which were also detected by x-ray diffraction and scanning electron microscopy. In the second phase, between days 6 and 13, magnetic resonance microscopy properties appear to plateau as amorphous calcium carbonate droplets began to coalesce within the intrafibrillar space of collagen. In the third phase, after day 15, the amorphous mineral phase crystallized, resulting in a reduction in the absolute intensity of the collagen diffraction pattern. We speculate that magnetization transfer ratio values for collagen sponges, with similar collagen contents, increased from 0.25 ± 0.02 for control strips to a maximum value of 0.31 ± 0.04 at day 15 (p = 0.03) because mineral crystals greatly reduce the mobility of the collagen fibrils. PMID:18487295

  19. Magnetic resonance spectroscopy of the human brain

    NASA Astrophysics Data System (ADS)

    Strózik-Kotlorz, D.

    2014-01-01

    I give a brief description of the magnetic resonance spectroscopy (MRS) in the human brain examinations. MRS allows a noninvasive chemical analysis of the brain using a standard high field MR system. Nowadays, the dominant form of MR brain spectroscopy is proton spectroscopy. Two main techniques of MRS, which utilize the chemical shift of metabolites in the external magnetic field, are SVS (single voxel) and CSI (single slice). The major peaks in the spectrum of a normal brain include NAA, Cr, Cho and m-Ins, which are neuronal, energetic, membrane turnover and glial markers, respectively. In disease, two pathological metabolites can be found in the brain spectra: Lac, which is end product of anaerobic glycolysis and Lip, which is a marker of membrane breakdown, occurring in necrosis. The common way to analyze clinical spectra is to determine metabolite ratios, e.g. NAA/Cr, Cho/Cr, Cho/NAA. This analysis permits a safe and noninvasive examination of the brain tissue as each disease state has its own characteristic spectroscopic image. MRS is a valuable diagnostic tool in such clinical applications as detecting brain tumors and differentiating tumors from inflammatory and infectious processes. Proton MRS is also very helpful in diagnostic of ischemic lesions, Alzheimer's disease and hepatic encephalopathy. The MRS brain spectra should always be correlated with the Magnetic Resonance Imaging (MRI) results and alone cannot make neurological diagnosis.

  20. Magnetic resonance at the quantum limit

    NASA Astrophysics Data System (ADS)

    Bertet, Patrice

    The detection and characterization of paramagnetic species by electron-spin resonance (ESR) spectroscopy has numerous applications in chemistry, biology, and materials science. Most ESR spectrometers rely on the inductive detection of the small microwave signals emitted by the spins during their Larmor precession into a microwave resonator in which they are embedded. Using the tools offered by circuit Quantum Electrodynamics (QED), namely high quality factor superconducting micro-resonators and Josephson parametric amplifiers that operate at the quantum limit when cooled at 20mK, we report an increase of the sensitivity of inductively detected ESR by 4 orders of magnitude over the state-of-the-art, enabling the detection of 1700 Bismuth donor spins in silicon with a signal-to-noise ratio of 1 in a single echo. We also demonstrate that the energy relaxation time of the spins is limited by spontaneous emission of microwave photons into the measurement line via the resonator, which opens the way to on-demand spin initialization via the Purcell effect. These results constitute a first step towards circuit QED experiments with magnetically coupled individual spins.

  1. Magnetic resonance force detection using a membrane resonator

    NASA Astrophysics Data System (ADS)

    Scozzaro, Nicolas; Ruchotzke, William; Belding, Amanda; Cardellino, Jeremy; Blomberg, Erick; McCullian, Brendan; Bhallamudi, Vidya; Pelekhov, Denis; Hammel, P. Chris

    Silicon nitride (Si3N4) membranes are commercially-available, versatile structures that have a variety of applications. Although most commonly used as the support structure for transmission electron microscopy (TEM) studies, membranes are also ultrasensitive high-frequency mechanical oscillators. The sensitivity stems from the high quality factor Q 106 , which has led to applications in sensitive quantum optomechanical experiments. The high sensitivity also opens the door to ultrasensitive force detection applications. We report force detection of electron spin magnetic resonance at 300 K using a Si3N4 membrane with a force sensitivity of 4 fN/√{ Hz}, and a potential low temperature sensitivity of 25 aN/√{ Hz}. Given membranes' sensitivity, robust construction, large surface area and low cost, SiN membranes can potentially serve as the central component of a compact room-temperature ESR and NMR instrument that has superior spatial resolution to conventional NMR.

  2. Magnetic resonance acoustic radiation force imaging

    PubMed Central

    McDannold, Nathan; Maier, Stephan E.

    2008-01-01

    Acoustic radiation force impulse imaging is an elastography method developed for ultrasound imaging that maps displacements produced by focused ultrasound pulses systematically applied to different locations. The resulting images are “stiffness weighted” and yield information about local mechanical tissue properties. Here, the feasibility of magnetic resonance acoustic radiation force imaging (MR-ARFI) was tested. Quasistatic MR elastography was used to measure focal displacements using a one-dimensional MRI pulse sequence. A 1.63 or 1.5 MHz transducer supplied ultrasound pulses which were triggered by the magnetic resonance imaging hardware to occur before a displacement-encoding gradient. Displacements in and around the focus were mapped in a tissue-mimicking phantom and in an ex vivo bovine kidney. They were readily observed and increased linearly with acoustic power in the phantom (R2=0.99). At higher acoustic power levels, the displacement substantially increased and was associated with irreversible changes in the phantom. At these levels, transverse displacement components could also be detected. Displacements in the kidney were also observed and increased after thermal ablation. While the measurements need validation, the authors have demonstrated the feasibility of detecting small displacements induced by low-power ultrasound pulses using an efficient magnetic resonance imaging pulse sequence that is compatible with tracking of a dynamically steered ultrasound focal spot, and that the displacement increases with acoustic power. MR-ARFI has potential for elastography or to guide ultrasound therapies that use low-power pulsed ultrasound exposures, such as drug delivery. PMID:18777934

  3. Molecular structure and motion in zero field magnetic resonance

    SciTech Connect

    Jarvie, T.P.

    1989-10-01

    Zero field magnetic resonance is well suited for the determination of molecular structure and the study of motion in disordered materials. Experiments performed in zero applied magnetic field avoid the anisotropic broadening in high field nuclear magnetic resonance (NMR) experiments. As a result, molecular structure and subtle effects of motion are more readily observed.

  4. Magnetic resonance imaging in central pontine myelinolysis.

    PubMed Central

    Thompson, P D; Miller, D; Gledhill, R F; Rossor, M N

    1989-01-01

    Magnetic resonance imaging (MRI) was performed in two patients in whom a clinical diagnosis of central pontine myelinolysis (CPM) had been made. MRI showed lesions in the pons in both cases about 2 years after the illness, at a time when the spastic quadriparesis and pseudobulbar palsy had recovered. The persisting abnormal signals in CPM are likely to be due to fibrillary gliosis. Persistence of lesions on MRI means that the diagnosis of CPM may be electively, after the acute illness has resolved. Images PMID:2732743

  5. Multiparametric magnetic resonance imaging of prostate cancer.

    PubMed

    Hedgire, Sandeep S; Oei, Tamara N; McDermott, Shaunagh; Cao, Kai; Patel M, Zena; Harisinghani, Mukesh G

    2012-07-01

    In India, prostate cancer has an incidence rate of 3.9 per 100,000 men and is responsible for 9% of cancer-related mortality. It is the only malignancy that is diagnosed with an apparently blind technique, i.e., transrectal sextant biopsy. With increasing numbers of high-Tesla magnetic resonance imaging (MRI) equipment being installed in India, the radiologist needs to be cognizant about endorectal MRI and multiparametric imaging for prostate cancer. In this review article, we aim to highlight the utility of multiparamteric MRI in prostate cancer. It plays a crucial role, mainly in initial staging, restaging, and post-treatment follow-up. PMID:23599562

  6. Insight into protein nuclear magnetic resonance research.

    PubMed

    Stoven, V; Lallemand, J Y; Abergel, D; Bouaziz, S; Delsuc, M A; Ekondzi, A; Guittet, E; Laplante, S; Le Goas, R; Malliavin, T

    1990-08-01

    Nuclear magnetic resonance (NMR) is one of the most powerful techniques to investigate the geometry of molecules in solution. It has been widely applied, in recent years, to the study of protein conformation. However, full reconstruction of the 3-D structure of such macro-molecules, still constitutes a real challenge for the spectroscopist. Skills as diverse as biology, spectroscopy, signal processing, or computer sciences, are required. This paper presents various aspects of the research in that domain, and our contribution to it. PMID:2126458

  7. Magnetic resonance imaging findings of intramammary metastases.

    PubMed

    Wienbeck, Susanne; Herzog, Aimee; Kinner, Sonja; Surov, Alexey

    2016-01-01

    The purpose of this study was to identify magnetic resonance imaging (MRI) findings of intramammary metastases (IM). We identified 8 cases with IM, which were investigated by breast MRI (1.5T). In every case, the diagnosis of IM was proven histopathologically on breast biopsy specimens. Overall, 187 IM were identified. IM had inconsistent MRI features, which cannot be clearly classify as benign or malignant. IM should be taken into consideration in the differential diagnosis of breast lesions to avoid possible misinterpretations. PMID:27133668

  8. Magnetic Resonance Imaging of Acute Stroke.

    PubMed

    Nael, Kambiz; Kubal, Wayne

    2016-05-01

    Neuroimaging plays a critical role in the management of patients with acute stroke syndrome, with diagnostic, therapeutic, and prognostic implications. A multiparametric magnetic resonance (MR) imaging protocol in the emergency setting can address both primary goals of neuroimaging (ie, detection of infarction and exclusion of hemorrhage) and secondary goals of neuroimaging (ie, identifying the site of arterial occlusion, tissue characterization for defining infarct core and penumbra, and determining stroke cause/mechanism). MR imaging provides accurate diagnosis of acute ischemic stroke (AIS) and can differentiate AIS from other potential differential diagnoses. PMID:27150320

  9. Magnetic Resonance of Pelvic and Gastrointestinal Emergencies.

    PubMed

    Wongwaisayawan, Sirote; Kaewlai, Rathachai; Dattwyler, Matthew; Abujudeh, Hani H; Singh, Ajay K

    2016-05-01

    Magnetic resonance (MR) imaging is gaining increased acceptance in the emergency setting despite the continued dominance of computed tomography. MR has the advantages of more precise tissue characterization, superior soft tissue contrast, and a lack of ionizing radiation. Traditional barriers to emergent MR are being overcome by streamlined imaging protocols and newer rapid-acquisition sequences. As the utilization of MR imaging in the emergency department increases, a strong working knowledge of the MR appearance of the most commonly encountered abdominopelvic pathologies is essential. In this article, MR imaging protocols and findings of acute pelvic, scrotal, and gastrointestinal pathologies are discussed. PMID:27150327

  10. New magnetic resonance imaging methods in nephrology

    PubMed Central

    Zhang, Jeff L.; Morrell, Glen; Rusinek, Henry; Sigmund, Eric; Chandarana, Hersh; Lerman, Lilach O.; Prasad, Pottumarthi Vara; Niles, David; Artz, Nathan; Fain, Sean; Vivier, Pierre H.; Cheung, Alfred K.; Lee, Vivian S.

    2013-01-01

    Established as a method to study anatomic changes, such as renal tumors or atherosclerotic vascular disease, magnetic resonance imaging (MRI) to interrogate renal function has only recently begun to come of age. In this review, we briefly introduce some of the most important MRI techniques for renal functional imaging, and then review current findings on their use for diagnosis and monitoring of major kidney diseases. Specific applications include renovascular disease, diabetic nephropathy, renal transplants, renal masses, acute kidney injury and pediatric anomalies. With this review, we hope to encourage more collaboration between nephrologists and radiologists to accelerate the development and application of modern MRI tools in nephrology clinics. PMID:24067433

  11. Developments in boron magnetic resonance imaging (MRI)

    SciTech Connect

    Schweizer, M.

    1995-11-01

    This report summarizes progress during the past year on maturing Boron-11 magnetic resonance imaging (MRI) methodology for noninvasive determination of BNCT agents (BSH) spatially in time. Three major areas are excerpted: (1) Boron-11 MRI of BSH distributions in a canine intracranial tumor model and the first human glioblastoma patient, (2) whole body Boron-11 MRI of BSH pharmacokinetics in a rat flank tumor model, and (3) penetration of gadolinium salts through the BBB as a function of tumor growth in the canine brain.

  12. Review: Magnetic resonance imaging techniques in ophthalmology

    PubMed Central

    Fagan, Andrew J.

    2012-01-01

    Imaging the eye with magnetic resonance imaging (MRI) has proved difficult due to the eye’s propensity to move involuntarily over typical imaging timescales, obscuring the fine structure in the eye due to the resulting motion artifacts. However, advances in MRI technology help to mitigate such drawbacks, enabling the acquisition of high spatiotemporal resolution images with a variety of contrast mechanisms. This review aims to classify the MRI techniques used to date in clinical and preclinical ophthalmologic studies, describing the qualitative and quantitative information that may be extracted and how this may inform on ocular pathophysiology. PMID:23112569

  13. Pelvic applications of diffusion magnetic resonance images.

    PubMed

    Coutinho, Antonio C; Krishnaraj, Arun; Pires, Cintia E; Bittencourt, Leonardo K; Guimarães, Alexander R

    2011-02-01

    Diffusion-weighted imaging (DWI) is a powerful imaging technique in neuroimaging; its value in abdominal and pelvic imaging has only recently been appreciated as a result of improvements in magnetic resonance imaging technology. There is growing interest in the use of DWI for evaluating pathology in the pelvis. Its ability to noninvasively characterize tissues and to depict changes at a cellular level allows DWI to be an effective complement to conventional sequences of pelvic imaging, especially in oncologic patients. The addition of DWI may obviate contrast material in those with renal insufficiency or contrast material allergy. PMID:21129639

  14. Emergency Magnetic Resonance Imaging of Musculoskeletal Trauma.

    PubMed

    Kumaravel, Manickam; Weathers, William M

    2016-05-01

    Musculoskeletal (MSK) trauma is commonly encountered in the emergency department. Computed tomography and radiography are the main forms of imaging assessment, but the use of magnetic resonance (MR) imaging has become more common in the emergency room (ER) setting for evaluation of low-velocity/sports-related injury and high-velocity injury. The superior soft tissue contrast and detail provided by MR imaging gives clinicians a powerful tool in the management of acute MSK injury in the ER. This article provides an overview of techniques and considerations when using MR imaging in the evaluation of some of the common injuries seen in the ER setting. PMID:27150325

  15. Approach to breast magnetic resonance imaging interpretation.

    PubMed

    Palestrant, Sarah; Comstock, Christopher E; Moy, Linda

    2014-05-01

    With the increasing use of breast magnetic resonance (MR) imaging comes the expectation that the breast radiologist is as fluent in its interpretation as in that of mammography and breast ultrasonography. Knowledge of who should be included for imaging and how to perform the imaging are as essential as interpreting the images. When reading the examination, the radiologist should approach the images from both a global and focused perspective, synthesizing findings into a report that includes a management plan. This article reviews a systematic and organized approach to breast MR imaging interpretation. PMID:24792657

  16. Cardiovascular magnetic resonance in systemic hypertension

    PubMed Central

    2012-01-01

    Systemic hypertension is a highly prevalent potentially modifiable cardiovascular risk factor. Imaging plays an important role in the diagnosis of underlying causes for hypertension, in assessing cardiovascular complications of hypertension, and in understanding the pathophysiology of the disease process. Cardiovascular magnetic resonance (CMR) provides accurate and reproducible measures of ventricular volumes, mass, function and haemodynamics as well as uniquely allowing tissue characterization of diffuse and focal fibrosis. In addition, CMR is well suited for exclusion of common secondary causes for hypertension. We review the current and emerging clinical and research applications of CMR in hypertension. PMID:22559053

  17. Magnetic Field Gradient Calibration as an Experiment to Illustrate Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Seedhouse, Steven J.; Hoffmann, Markus M.

    2008-01-01

    A nuclear magnetic resonance (NMR) spectroscopy experiment for the undergraduate physical chemistry laboratory is described that encompasses both qualitative and quantitative pedagogical goals. Qualitatively, the experiment illustrates how images are obtained in magnetic resonance imaging (MRI). Quantitatively, students experience the…

  18. Metabolite specific proton magnetic resonance imaging

    SciTech Connect

    Hurd, R.E.; Freeman, D.M.

    1989-06-01

    An imaging method is described that makes use of proton double quantum nuclear magnetic resonance (NMR) to construct images based on selected metabolites such as lactic acid. The optimization of the method is illustrated in vitro, followed by in vivo determination of lactic acid distribution in a solid tumor model. Water suppression and editing of lipid signals are such that two-dimensional spectra of lactic acid may be obtained from a radiation-induced fibrosarcoma (RIF-1) tumor in under 1 min and lactic acid images from the same tumor in under 1 hr at 2.0 T. This technique provides a fast and reproducible method at moderate magnetic field strength for mapping biologically relevant metabolites.

  19. In vivo nuclear magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Leblanc, A.

    1986-05-01

    During the past year the Woodlands Baylor Magnetic Resonance Imaging (MRI) facility became fully operational. A detailed description of this facility is given. One significant instrument addition this year was the 100 MHz, 40cm bore superconducting imaging spectrometer. This instrument gives researchers the capability to acquire high energy phosphate spectra. This will be used to investigate ATP, phosphocreatinine and inorganic phosphate changes in normal and atrophied muscle before, during and after exercise. An exercise device for use within the bore of the imaging magnet is under design/construction. The results of a study of T sub 1 and T sub 2 changes in atrophied muscle in animals and human subjects are given. The imaging and analysis of the lower leg of 15 research subjects before and after 5 weeks of complete bedrest was completed. A compilation of these results are attached.

  20. In vivo nuclear magnetic resonance imaging

    NASA Technical Reports Server (NTRS)

    Leblanc, A.

    1986-01-01

    During the past year the Woodlands Baylor Magnetic Resonance Imaging (MRI) facility became fully operational. A detailed description of this facility is given. One significant instrument addition this year was the 100 MHz, 40cm bore superconducting imaging spectrometer. This instrument gives researchers the capability to acquire high energy phosphate spectra. This will be used to investigate ATP, phosphocreatinine and inorganic phosphate changes in normal and atrophied muscle before, during and after exercise. An exercise device for use within the bore of the imaging magnet is under design/construction. The results of a study of T sub 1 and T sub 2 changes in atrophied muscle in animals and human subjects are given. The imaging and analysis of the lower leg of 15 research subjects before and after 5 weeks of complete bedrest was completed. A compilation of these results are attached.

  1. Multiparametric magnetic resonance imaging: Current role in prostate cancer management.

    PubMed

    Ueno, Yoshiko; Tamada, Tsutomu; Bist, Vipul; Reinhold, Caroline; Miyake, Hideaki; Tanaka, Utaru; Kitajima, Kazuhiro; Sugimura, Kazuro; Takahashi, Satoru

    2016-07-01

    Digital rectal examination, serum prostate-specific antigen screening and transrectal ultrasound-guided biopsy are conventionally used as screening, diagnostic and surveillance tools for prostate cancer. However, they have limited sensitivity and specificity. In recent years, the role of multiparametric magnetic resonance imaging has steadily grown, and is now part of the standard clinical management in many institutions. In multiparametric magnetic resonance imaging, the morphological assessment of T2-weighted imaging is correlated with diffusion-weighted imaging, dynamic contrast-enhanced imaging perfusion and/or magnetic resonance spectroscopic imaging. Multiparametric magnetic resonance imaging is currently regarded as the most sensitive and specific imaging technique for the evaluation of prostate cancer, including detection, staging, localization and aggressiveness evaluation. This article presents an overview of multiparametric magnetic resonance imaging, and discusses the current role of multiparametric magnetic resonance imaging in the different fields of prostate cancer management. PMID:27184019

  2. Plasmon coupling of magnetic resonances in an asymmetric gold semishell

    NASA Astrophysics Data System (ADS)

    Ye, Jian; Kong, Yan; Liu, Cheng

    2016-05-01

    The generation of magnetic dipole resonances in metallic nanostructures is of great importance for constructing near-zero or even negative refractive index metamaterials. Commonly, planar two-dimensional (2D) split-ring resonators or relevant structures are basic elements of metamaterials. In this work, we introduce a three-dimensional (3D) asymmetric Au semishell composed of two nanocups with a face-to-face geometry and demonstrate two distinct magnetic resonances spontaneously in the visible–near infrared optical wavelength regime. These two magnetic resonances are from constructive and destructive hybridization of magnetic dipoles of individual nanocups in the asymmetric semishell. In contrast, complete cancellation of magnetic dipoles in the symmetric semishell leads to only a pronounced electric mode with near-zero magnetic dipole moment. These 3D asymmetric resonators provide new ways for engineering hybrid resonant modes and ultra-high near-field enhancement for the design of 3D metamaterials.

  3. Fano resonance generated by magnetic scatterer in micro metal slit

    NASA Astrophysics Data System (ADS)

    Zhou, Yun-Song; Wang, Pei-Jie; Wang, Hai; Feng, Sheng-Fei

    2014-09-01

    A micro metal slit/magnetic scatterer structure is proposed to generate electromagnetic Fano resonance. The magnetic scatterer is formed by infinite long split cylinder resonator array. The analytical transmissivity formulas are deduced from Maxwell electromagnetic theory and the Fano resonance transmission is achieved by the theoretical calculations. The enhancement of environment refractive index leads to an ultrasensitive and linear red shift of resonance peak in the THz range.

  4. Magnetic resonance imaging of the central nervous system

    SciTech Connect

    Brant-Zawadzki, M.; Norman, D.

    1987-01-01

    This book presents the papers on technological advancement and diagnostic uses g magnetic resonance imaging. A comparative evaluation with computerized tomography is presented. Topics covered are imaging principles g magnetic resonance;instrumentation of magnetic resonance (MR);pathophysiology;quality and limitations g images;NMR imaging of brain and spinal cord;MR spectroscopy and its applications;neuroanatomy;Congenital malformations of brain and MR imaging;planning g MR imaging of spine and head and neck imaging.

  5. Science Drivers and Technical Challenges for Advanced Magnetic Resonance

    SciTech Connect

    Mueller, Karl T.; Pruski, Marek; Washton, Nancy M.; Lipton, Andrew S.

    2013-03-07

    This report recaps the "Science Drivers and Technical Challenges for Advanced Magnetic Resonance" workshop, held in late 2011. This exploratory workshop's goal was to discuss and address challenges for the next generation of magnetic resonance experimentation. During the workshop, participants from throughout the world outlined the science drivers and instrumentation demands for high-field dynamic nuclear polarization (DNP) and associated magnetic resonance techniques, discussed barriers to their advancement, and deliberated the path forward for significant and impactful advances in the field.

  6. Massive subchorionic thrombosis followed by magnetic resonance imaging.

    PubMed

    Himoto, Yuki; Okumura, Ryosuke; Tsuji, Natsuki; Nagano, Tadayoshi; Fujimoto, Masakazu; Yamaoka, Toshihide; Kohno, Shigene

    2012-01-01

    Massive subchorionic thrombosis is a rare condition, defined as a large thrombus confined to the subchorionic space. It is associated with poor perinatal prognosis. However, prenatal diagnosis by ultrasonography is often difficult. We report a case of massive subchorionic thrombosis developing dermatomyositis after the delivery, followed by magnetic resonance imaging. Moreover, we review other 4 cases assessed with magnetic resonance imaging. Magnetic resonance imaging is very useful for confirmation of diagnosis and follow-up in combination with ultrasonography. PMID:22592619

  7. General review of magnetic resonance elastography

    PubMed Central

    Low, Gavin; Kruse, Scott A; Lomas, David J

    2016-01-01

    Magnetic resonance elastography (MRE) is an innovative imaging technique for the non-invasive quantification of the biomechanical properties of soft tissues via the direct visualization of propagating shear waves in vivo using a modified phase-contrast magnetic resonance imaging (MRI) sequence. Fundamentally, MRE employs the same physical property that physicians utilize when performing manual palpation - that healthy and diseased tissues can be differentiated on the basis of widely differing mechanical stiffness. By performing “virtual palpation”, MRE is able to provide information that is beyond the capabilities of conventional morphologic imaging modalities. In an era of increasing adoption of multi-parametric imaging approaches for solving complex problems, MRE can be seamlessly incorporated into a standard MRI examination to provide a rapid, reliable and comprehensive imaging evaluation at a single patient appointment. Originally described by the Mayo Clinic in 1995, the technique represents the most accurate non-invasive method for the detection and staging of liver fibrosis and is currently performed in more than 100 centers worldwide. In this general review, the mechanical properties of soft tissues, principles of MRE, clinical applications of MRE in the liver and beyond, and limitations and future directions of this discipline -are discussed. Selected diagrams and images are provided for illustration. PMID:26834944

  8. Magnetic Resonance Imaging in Pediatric Pulmonary Hypertension

    PubMed Central

    Olgunturk, Rana; Cevik, Ayhan; Terlemez, Semiha; Kacar, Emre; Oner, Yusuf Ali

    2015-01-01

    The present study aims to determine the efficacy and reliability of cardiovascular magnetic resonance imaging in establishing the diagnosis and prognosis of pulmonary hypertension in children. This is a retrospective comparison of 25 children with pulmonary hypertension and a control group comprising 19 healthy children. The diagnosis of pulmonary hypertension was made when the mean pulmonary artery pressure was ≥25 mmHg by catheter angiography. The children with pulmonary hypertension had significantly lower body mass indices than did the healthy children (P=0.048). In addition, the children with pulmonary hypertension had significantly larger main pulmonary artery diameters and ascending aortic diameters (both P=0.001) but statistically similar ratios of main pulmonary artery diameter-to-ascending aortic diameter. If the main pulmonary artery diameter was ≥25 mm, pediatric pulmonary hypertension was diagnosed with 72% sensitivity and 84% specificity. In the event that the ratio of main pulmonary artery diameter-to-ascending aorta diameter was ≥1, pediatric pulmonary hypertension was diagnosed with 60% sensitivity and 53% specificity. When compared with children who had New York Heart Association functional class II pulmonary hypertension, the children with functional class III pulmonary hypertension had significantly larger main (P=0.046), right (P=0.036), and left (P=0.003) pulmonary arteries. Cardiovascular magnetic resonance imaging is useful in the diagnosis of children with pulmonary hypertension. Pediatric pulmonary hypertension can be diagnosed with high sensitivity and specificity when the main pulmonary artery diameter measures ≥25 mm. PMID:26175631

  9. General review of magnetic resonance elastography.

    PubMed

    Low, Gavin; Kruse, Scott A; Lomas, David J

    2016-01-28

    Magnetic resonance elastography (MRE) is an innovative imaging technique for the non-invasive quantification of the biomechanical properties of soft tissues via the direct visualization of propagating shear waves in vivo using a modified phase-contrast magnetic resonance imaging (MRI) sequence. Fundamentally, MRE employs the same physical property that physicians utilize when performing manual palpation - that healthy and diseased tissues can be differentiated on the basis of widely differing mechanical stiffness. By performing "virtual palpation", MRE is able to provide information that is beyond the capabilities of conventional morphologic imaging modalities. In an era of increasing adoption of multi-parametric imaging approaches for solving complex problems, MRE can be seamlessly incorporated into a standard MRI examination to provide a rapid, reliable and comprehensive imaging evaluation at a single patient appointment. Originally described by the Mayo Clinic in 1995, the technique represents the most accurate non-invasive method for the detection and staging of liver fibrosis and is currently performed in more than 100 centers worldwide. In this general review, the mechanical properties of soft tissues, principles of MRE, clinical applications of MRE in the liver and beyond, and limitations and future directions of this discipline -are discussed. Selected diagrams and images are provided for illustration. PMID:26834944

  10. PLANTAR THROMBOPHLEBITIS: MAGNETIC RESONANCE IMAGING FINDINGS

    PubMed Central

    Miranda, Frederico Celestino; Carneiro, Renato Duarte; Longo, Carlos Henrique; Fernandes, Túlio Diniz; Rosemberg, Laércio Alberto; de Gusmão Funari, Marcelo Buarque

    2015-01-01

    Objective: Demonstrate the magnetic resonance imaging (MRI) findings in plantar thrombophlebitis. Methods: Retrospective review of twenty patients with pain in the plantar region of the foot, in which the MRI findings indicated plantar thrombophlebitis. Results: A total of fourteen men and six women, mean age 46.7 years were evaluated. Eight of these patients also underwent Doppler ultrasonography, which confirmed the thrombophlebitis. The magnetic resonance images were evaluated in consensus by two radiologists with experience in musculoskeletal radiology (more than 10 years each), showing perivascular edema in all twenty patients (100%) and muscle edema in nineteen of the twenty patients (95%). All twenty patients had intraluminal intermediate signal intensity on T2-weighted (100%) and venous ectasia was present in seventeen of the twenty cases (85%). Collateral veins were visualized in one of the twenty patients (5%). All fourteen cases (100%), in which intravenous contrast was administered, showed perivenular tissues enhancement and intraluminal filling defect. Venous ectasia, loss of compressibility and no flow on Doppler ultrasound were also observed in all eight cases examined by the method. Conclusion: MRI is a sensitive in the evaluation of plant thrombophlebitis in patients with plantar foot pain. PMID:27047898

  11. Magnetic resonance elastography hardware design: a survey.

    PubMed

    Tse, Z T H; Janssen, H; Hamed, A; Ristic, M; Young, I; Lamperth, M

    2009-05-01

    Magnetic resonance elastography (MRE) is an emerging technique capable of measuring the shear modulus of tissue. A suspected tumour can be identified by comparing its properties with those of tissues surrounding it; this can be achieved even in deep-lying areas as long as mechanical excitation is possible. This would allow non-invasive methods for cancer-related diagnosis in areas not accessible with conventional palpation. An actuating mechanism is required to generate the necessary tissue displacements directly on the patient in the scanner and three different approaches, in terms of actuator action and position, exist to derive stiffness measurements. However, the magnetic resonance (MR) environment places considerable constraints on the design of such devices, such as the possibility of mutual interference between electrical components, the scanner field, and radio frequency pulses, and the physical space restrictions of the scanner bore. This paper presents a review of the current solutions that have been developed for MRE devices giving particular consideration to the design criteria including the required vibration frequency and amplitude in different applications, the issue of MR compatibility, actuation principles, design complexity, and scanner synchronization issues. The future challenges in this field are also described. PMID:19499839

  12. Magnetic resonance imaging. Application to family practice.

    PubMed Central

    Goh, R. H.; Somers, S.; Jurriaans, E.; Yu, J.

    1999-01-01

    OBJECTIVE: To review indications, contraindications, and risks of using magnetic resonance imaging (MRI) in order to help primary care physicians refer patients appropriately for MRI, screen for contraindications to using MRI, and educate patients about MRI. QUALITY OF EVIDENCE: Recommendations are based on classic textbooks, the policies of our MRI group, and a literature search using MEDLINE with the MeSH headings magnetic resonance imaging, brain, musculoskeletal, and spine. The search was limited to human, English-language, and review articles. Evidence in favour of using MRI for imaging the head, spine, and joints is well established. For cardiac, abdominal, and pelvic conditions, MRI has been shown useful for certain indications, usually to complement other modalities. MAIN MESSAGE: For demonstrating soft tissue conditions, MRI is better than computed tomography (CT), but CT shows bone and acute bleeding better. Therefore, patients with trauma or suspected intracranial bleeding should have CT. Tumours, congenital abnormalities, vascular structures, and the cervical or thoracic spine show better on MRI. Either modality can be used for lower back pain. Cardiac, abdominal, and pelvic abnormalities should be imaged with ultrasound or CT before MRI. Contraindications for MRI are mainly metallic implants or shrapnel, severe claustrophobia, or obesity. CONCLUSIONS: With the increasing availability of MRI scanners in Canada, better understanding of the indications, contraindications, and risks will be helpful for family physicians and their patients. Images Figure 1 Figure 2 Figure 3 Figure 4 Figure 5 Figure 6 Figure 7 Figure 8 Figure 9 Figure 10 PMID:10509224

  13. Magnetic resonance-guided thermal surgery.

    PubMed

    Cline, H E; Schenck, J F; Watkins, R D; Hynynen, K; Jolesz, F A

    1993-07-01

    A demonstration of MR guided thermal surgery involved experiments with imaging of focused ultrasound in an MRI system, measurements of the thermal transients and a thermal analysis of the resulting images. Both the heat distribution and the creation of focused ultrasound lesions in gel phantoms, in vitro bovine muscle and in vivo rabbit muscle were monitored with magnetic resonance imaging. Thermal surgical procedures were modeled by an elongated gaussian heat source where heat flow is controlled by tissue thermal properties and tissue perfusion. Temperature profiles were measured with thermocouples or calculated from magnetic resonance imaging in agreement with the model. A 2-s T1-weighted gradient-refocused acquisition provided thermal profiles needed to localize the heat distribution produced by a 4-s focused ultrasound pulse. Thermal analysis of the images give an effective thermal diffusion coefficient of 0.0015 cm2/s in gel and 0.0033 cm2/s in muscle. The lesions were detected using a T2-weighted spin-echo or fast spin-echo pulse sequence in agreement with muscle tissue sections. Potential thermal surgery applications are in the prostate, liver, kidney, bladder, breast, eye and brain. PMID:8371680

  14. Magnetic resonance imaging in pediatric pulmonary hypertension.

    PubMed

    Pektas, Ayhan; Olgunturk, Rana; Cevik, Ayhan; Terlemez, Semiha; Kacar, Emre; Oner, Yusuf Ali

    2015-06-01

    The present study aims to determine the efficacy and reliability of cardiovascular magnetic resonance imaging in establishing the diagnosis and prognosis of pulmonary hypertension in children. This is a retrospective comparison of 25 children with pulmonary hypertension and a control group comprising 19 healthy children. The diagnosis of pulmonary hypertension was made when the mean pulmonary artery pressure was ≥25 mmHg by catheter angiography. The children with pulmonary hypertension had significantly lower body mass indices than did the healthy children (P=0.048). In addition, the children with pulmonary hypertension had significantly larger main pulmonary artery diameters and ascending aortic diameters (both P=0.001) but statistically similar ratios of main pulmonary artery diameter-to-ascending aortic diameter. If the main pulmonary artery diameter was ≥25 mm, pediatric pulmonary hypertension was diagnosed with 72% sensitivity and 84% specificity. In the event that the ratio of main pulmonary artery diameter-to-ascending aorta diameter was ≥1, pediatric pulmonary hypertension was diagnosed with 60% sensitivity and 53% specificity. When compared with children who had New York Heart Association functional class II pulmonary hypertension, the children with functional class III pulmonary hypertension had significantly larger main (P=0.046), right (P=0.036), and left (P=0.003) pulmonary arteries. Cardiovascular magnetic resonance imaging is useful in the diagnosis of children with pulmonary hypertension. Pediatric pulmonary hypertension can be diagnosed with high sensitivity and specificity when the main pulmonary artery diameter measures ≥25 mm. PMID:26175631

  15. Magnetic resonance imaging of spinal injury.

    PubMed

    Tracy, P T; Wright, R M; Hanigan, W C

    1989-03-01

    Magnetic resonance imaging (MRI) was performed on 30 patients following spinal injury (SI). Spin-echo sequences and surface coils were used for all patients. Plain radiographs, high-resolution computed tomography (CT), and MRI were compared for the delineation of bone, disc, and ligament injury, measurement of sagittal spinal canal diameter and subluxation, epidural hematoma, and spinal cord structure. Myelography or intrathecal contrast-enhanced CT were not performed on any of these patients. Magnetic resonance imaging accurately delineated intraspinal pathology in two of four patients with acute penetrating SI, and was normal in the other two patients. In 16 patients with acute nonpenetrating SI, MRI was superior to CT for visualizing injuries to discs, ligaments, and the spinal cord, while CT was superior to MRI in characterizing bony injury. Computed tomography and MRI provided similar measurements of subluxation in six of six patients and of sagittal spinal canal diameter in three of four patients. In ten patients with chronic SI, MRI demonstrated post-traumatic cysts, myelomalacia, spinal cord edema, and the presence or absence of spinal cord compression. In patients with acute penetrating SI and chronic SI, MRI provided comprehensive clinical information. In patients with acute nonpenetrating SI, the information obtained by MRI complemented the data given by plain radiographs and CT, allowing clinical decisions to be made without the need of invasive imaging modalities. PMID:2711244

  16. Phosphorus 31 nuclear magnetic resonance examination of female reproductive tissues

    SciTech Connect

    Noyszewski, E.A.; Raman, J.; Trupin, S.R.; McFarlin, B.L.; Dawson, M.J. )

    1989-08-01

    Nuclear magnetic resonance spectroscopy is a powerful method of investigating the relationship between metabolism and function in living tissues. We present evidence that the phosphorus 31 spectra of myometrium and placenta are functions of physiologic state and gestational age. Specific spectroscopic abnormalities are observed in association with disorders of pregnancy and gynecologic diseases. Our results suggest that noninvasive nuclear magnetic resonance spectroscopy examinations may sometimes be a useful addition to magnetic resonance imaging examinations, and that nuclear magnetic resonance spectroscopy of biopsy specimens could become a cost-effective method of evaluating certain biochemical abnormalities.

  17. Reciprocity and gyrotropism in magnetic resonance transduction

    SciTech Connect

    Tropp, James

    2006-12-15

    We give formulas for transduction in magnetic resonance - i.e., the appearance of an emf due to Larmor precession of spins - based upon the modified Lorentz reciprocity principle for gyrotropic (also called 'nonreciprocal') media, i.e., in which a susceptibility tensor is carried to its transpose by reversal of an external static field [cf., R. F. Harrington and A. T. Villeneuve IRE Trans. Microwave Theory and Technique MTT6, 308 (1958)]. Prior applications of reciprocity to magnetic resonance, despite much success, have ignored the gyrotropism which necessarily arises due to nuclear and/or unpaired electronic spins. For detection with linearly polarized fields, oscillating at the Larmor frequency, the emf is written in terms of a volume integral containing a product of two factors which we define as the antenna patterns, i.e. (H{sub 1x}{+-}iH{sub 1y}), where, e.g., for a single transceive antenna, the H's are just the spatially dependent oscillatory magnetic field strengths, per the application of some reference current at the antenna terminals, with the negative sign obtaining for transmission, and the positive for reception. Similar expressions hold for separate transmit and receive antennas; expressions are also given for circular polarization of the fields. We then exhibit a receive-only array antenna of two elements for magnetic resonance imaging of protons, which, due an intensity artifact arising from stray reactive coupling of the elements, produces, despite its own bilateral symmetry, asymmetric proton NMR images of a symmetric cylindrical phantom containing aqueous saline solution [J. Tropp and T. Schirmer, J. Magn. Reson. 151, 146 (2001)]. Modification of this two-port antenna, to function in transmit-receive mode, allows us to demonstrate highly nonreciprocal behavior: that is, to record images (of cylindrical test phantoms containing aqueous saline solution) whose appearance dramatically changes, when the roles of transmission and reception are

  18. Nuclear magnetic resonance in magnets with a helicoidal magnetic structure in an external magnetic field

    NASA Astrophysics Data System (ADS)

    Tankeyev, A. P.; Borich, M. A.; Smagin, V. V.

    2014-11-01

    In this review, the static and dynamic properties of a magnet with a helicoidal magnetic structure placed in an external magnetic field are discussed. The results of the investigation of its ground state and spectra, as well as the amplitudes of the spin excitations are presented. The temperature and field dependences of the basic thermodynamic characteristics (heat capacity, magnetization, and magnetic susceptibility) have been calculated in the spin-wave approximation. The results of calculating the local and integral dynamic magnetic susceptibility are given. This set of data represents a methodical basis for constructing a consistent (in the framework of unified approximations) picture of the NMR absorption in the magnet under consideration. Both local NMR characteristics (resonance frequency, line broadening, enhancement coefficient) and integral characteristics (resultant shape of the absorption line with its specific features) have been calculated. The effective Hamiltonian of the Suhl-Nakamura interaction of nuclear spins through spin waves has been constructed. The second moment and the local broadening of the line of the NMR absorption caused by this interaction have been calculated. The role of the basic local inhomogeneities in the formation of the integral line of the NMR absorption has been analyzed. The opportunities for the experimental NMR investigations in magnets with a chiral spin structure are discussed.

  19. Secondary resonance magnetic force microscopy using an external magnetic field for characterization of magnetic thin films

    NASA Astrophysics Data System (ADS)

    Liu, Dongzi; Mo, Kangxin; Ding, Xidong; Zhao, Liangbing; Lin, Guocong; Zhang, Yueli; Chen, Dihu

    2015-09-01

    A bimodal magnetic force microscopy (MFM) that uses an external magnetic field for the detection and imaging of magnetic thin films is developed. By applying the external modulation magnetic field, the vibration of a cantilever probe is excited by its magnetic tip at its higher eigenmode. Using magnetic nanoparticle samples, the capacity of the technique which allows single-pass imaging of topography and magnetic forces is demonstrated. For the detection of magnetic properties of thin film materials, its signal-to-noise ratio and sensitivity are demonstrated to be superior to conventional MFM in lift mode. The secondary resonance MFM technique provides a promising tool for the characterization of nanoscale magnetic properties of various materials, especially of magnetic thin films with weak magnetism.

  20. BROADBAND EXCITATION IN NUCLEAR MAGNETIC RESONANCE

    SciTech Connect

    Tycko, R.

    1984-10-01

    Theoretical methods for designing sequences of radio frequency (rf) radiation pulses for broadband excitation of spin systems in nuclear magnetic resonance (NMR) are described. The sequences excite spins uniformly over large ranges of resonant frequencies arising from static magnetic field inhomogeneity, chemical shift differences, or spin couplings, or over large ranges of rf field amplitudes. Specific sequences for creating a population inversion or transverse magnetization are derived and demonstrated experimentally in liquid and solid state NMR. One approach to broadband excitation is based on principles of coherent averaging theory. A general formalism for deriving pulse sequences is given, along with computational methods for specific cases. This approach leads to sequences that produce strictly constant transformations of a spin system. The importance of this feature in NMR applications is discussed. A second approach to broadband excitation makes use of iterative schemes, i.e. sets of operations that are applied repetitively to a given initial pulse sequences, generating a series of increasingly complex sequences with increasingly desirable properties. A general mathematical framework for analyzing iterative schemes is developed. An iterative scheme is treated as a function that acts on a space of operators corresponding to the transformations produced by all possible pulse sequences. The fixed points of the function and the stability of the fixed points are shown to determine the essential behavior of the scheme. Iterative schemes for broadband population inversion are treated in detail. Algebraic and numerical methods for performing the mathematical analysis are presented. Two additional topics are treated. The first is the construction of sequences for uniform excitation of double-quantum coherence and for uniform polarization transfer over a range of spin couplings. Double-quantum excitation sequences are demonstrated in a liquid crystal system. The

  1. Acoustic noise during functional magnetic resonance imaginga)

    PubMed Central

    Ravicz, Michael E.; Melcher, Jennifer R.; Kiang, Nelson Y.-S.

    2007-01-01

    Functional magnetic resonance imaging (fMRI) enables sites of brain activation to be localized in human subjects. For studies of the auditory system, acoustic noise generated during fMRI can interfere with assessments of this activation by introducing uncontrolled extraneous sounds. As a first step toward reducing the noise during fMRI, this paper describes the temporal and spectral characteristics of the noise present under typical fMRI study conditions for two imagers with different static magnetic field strengths. Peak noise levels were 123 and 138 dB re 20 μPa in a 1.5-tesla (T) and a 3-T imager, respectively. The noise spectrum (calculated over a 10-ms window coinciding with the highest-amplitude noise) showed a prominent maximum at 1 kHz for the 1.5-T imager (115 dB SPL) and at 1.4 kHz for the 3-T imager (131 dB SPL). The frequency content and timing of the most intense noise components indicated that the noise was primarily attributable to the readout gradients in the imaging pulse sequence. The noise persisted above background levels for 300-500 ms after gradient activity ceased, indicating that resonating structures in the imager or noise reverberating in the imager room were also factors. The gradient noise waveform was highly repeatable. In addition, the coolant pump for the imager’s permanent magnet and the room air handling system were sources of ongoing noise lower in both level and frequency than gradient coil noise. Knowledge of the sources and characteristics of the noise enabled the examination of general approaches to noise control that could be applied to reduce the unwanted noise during fMRI sessions. PMID:11051496

  2. Development of hyperpolarized noble gas MRI

    NASA Astrophysics Data System (ADS)

    Albert, M. S.; Balamore, D.

    1998-02-01

    Magnetic resonance imaging using the MR signal from hyperpolarized noble gases 129Xe and 3He may become an important new diagnostic technique. Alex Pines (adapting the hyperpolarization technique pioneered by William Happer) presented MR spectroscopy studies using hyperpolarized 129Xe. The current authors recognized that the enormous enhancement in the detectability of 129Xe, promised by hyperpolarization, would solve the daunting SNR problems impeding their attempts to use 129Xe as an in vivo MR probe, especially in order to study the action of general anesthetics. It was hoped that hyperpolarized 129Xe MRI would yield resolutions equivalent to that achievable with conventional 1H 2O MRI, and that xenon's solubility in lipids would facilitate investigations of lipid-rich tissues that had as yet been hard to image. The publication of hyperpolarized 129Xe images of excised mouse lungs heralded the emergence of hyperpolarized noble-gas MRI. Using hyperpolarized 3He, researchers have obtained images of the lung gas space of guinea pigs and of humans. Lung gas images from patients with pulmonary disease have recently been reported. 3He is easier to hyperpolarize than 129Xe, and it yields a stronger MR signal, but its extremely low solubility in blood precludes its use for the imaging of tissue. Xenon, however, readily dissolves in blood, and the T1 of dissolved 129Xe is long enough for sufficient polarization to be carried by the circulation to distal tissues. Hyperpolarized 129Xe dissolved-phase tissue spectra from the thorax and head of rodents and humans have been obtained, as have chemical shift 129Xe images from the head of rats. Lung gas 129Xe images of rodents, and more recently of humans, have been reported. Hyperpolarized 129Xe MRI (HypX-MRI) may elucidate the link between the structure of the lung and its function. The technique may also be useful in identifying ventilation-perfusion mismatch in patients with pulmonary embolism, in staging and tracking the

  3. Reciprocity and gyrotropism in magnetic resonance transduction

    NASA Astrophysics Data System (ADS)

    Tropp, James

    2006-12-01

    We give formulas for transduction in magnetic resonance—i.e., the appearance of an emf due to Larmor precession of spins—based upon the modified Lorentz reciprocity principle for gyrotropic (also called “nonreciprocal”) media, i.e., in which a susceptibility tensor is carried to its transpose by reversal of an external static field [cf., R. F. Harrington and A. T. Villeneuve IRE Trans. Microwave Theory and Technique MTT6, 308 (1958)]. Prior applications of reciprocity to magnetic resonance, despite much success, have ignored the gyrotropism which necessarily arises due to nuclear and/or unpaired electronic spins. For detection with linearly polarized fields, oscillating at the Larmor frequency, the emf is written in terms of a volume integral containing a product of two factors which we define as the antenna patterns, i.e., (H1x±iH1y) , where, e.g., for a single transceive antenna, the H ’s are just the spatially dependent oscillatory magnetic field strengths, per the application of some reference current at the antenna terminals, with the negative sign obtaining for transmission, and the positive for reception. Similar expressions hold for separate transmit and receive antennas; expressions are also given for circular polarization of the fields. We then exhibit a receive-only array antenna of two elements for magnetic resonance imaging of protons, which, due an intensity artifact arising from stray reactive coupling of the elements, produces, despite its own bilateral symmetry, asymmetric proton NMR images of a symmetric cylindrical phantom containing aqueous saline solution [J. Tropp and T. Schirmer, J. Magn. Reson. 151, 146 (2001)]. Modification of this two-port antenna, to function in transmit-receive mode, allows us to demonstrate highly nonreciprocal behavior: that is, to record images (of cylindrical test phantoms containing aqueous saline solution) whose appearance dramatically changes, when the roles of transmission and reception are swapped

  4. Nuclear magnetic resonance studies of lens transparency

    SciTech Connect

    Beaulieu, C.F.

    1989-01-01

    Transparency of normal lens cytoplasm and loss of transparency in cataract were studied by nuclear magnetic resonance (NMR) methods. Phosphorus ({sup 31}P) NMR spectroscopy was used to measure the {sup 31}P constituents and pH of calf lens cortical and nuclear homogenates and intact lenses as a function of time after lens enucleation and in opacification produced by calcium. Transparency was measured with laser spectroscopy. Despite complete loss of adenosine triphosphate (ATP) within 18 hrs of enucleation, the homogenates and lenses remained 100% transparent. Additions of calcium to ATP-depleted cortical homogenates produced opacification as well as concentration-dependent changes in inorganic phosphate, sugar phosphates, glycerol phosphorylcholine and pH. {sup 1}H relaxation measurements of lens water at 200 MHz proton Larmor frequency studied temperature-dependent phase separation of lens nuclear homogenates. Preliminary measurements of T{sub 1} and T{sub 2} with non-equilibrium temperature changes showed a change in the slope of the temperature dependence of T{sub 1} and T{sub 2} at the phase separation temperature. Subsequent studies with equilibrium temperature changes showed no effect of phase separation on T{sub 1} or T{sub 2}, consistent with the phase separation being a low-energy process. {sup 1}H nuclear magnetic relaxation dispersion (NMRD) studies (measurements of the magnetic field dependence of the water proton 1/T{sub 1} relaxation rates) were performed on (1) calf lens nuclear and cortical homogenates (2) chicken lens homogenates, (3) native and heat-denatured egg white and (4) pure proteins including bovine {gamma}-II crystallin bovine serum albumin (BSA) and myoglobin. The NMRD profiles of all samples exhibited decreases in 1/T{sub 1} with increasing magnetic field.

  5. [Clinical applications of magnetic resonance cholangiopancreatography].

    PubMed

    Soto, J A; Castrillón, G A

    2007-01-01

    Magnetic resonance cholangiopancreatography (MRCP) is the most important diagnostic alternative that has been developed in recent years for the evaluation of the biliary and pancreatic ducts. The advantages of this technique are: it does not use contrast media or ionizing radiation; it is noninvasive and complication free; and, the examination is relatively short (approximately 20 to 30 minutes). MRCP has high sensitivity and specificity for diagnosing biliary dilatation and for determining the site and cause of stenosis. Its diagnostic precision for biliary and pancreatic stones is similar to that of endoscopic retrograde cholangiopancreatography (ERCP). MRCP has replaced ERCP in biliary and pancreatic anatomic variants. In unsuccessful ERCP, MRCP is nearly the only diagnostic modality for the evaluation of the biliary tract. Other applications include primary sclerosing cholangitis, stenosis after liver transplantation, and the evaluation of bilioenteric anastomoses. This article reviews the clinical applications of MRCP in the evaluation of biliopancreatic diseases. PMID:18021667

  6. Magnetic resonance imaging in Leber's optic neuropathy.

    PubMed Central

    Kermode, A G; Moseley, I F; Kendall, B E; Miller, D H; MacManus, D G; McDonald, W I

    1989-01-01

    Thirteen males with Leber's optic neuropathy had magnetic resonance imaging (MRI) of the brain, and in eight the optic nerves were imaged using STIR (Short Time Inversion Recovery) sequences. All optic nerve scans were abnormal. In seven with bilateral visual loss four showed bilateral increased optic nerve signal and three unilateral increase. The involvement was of the mid and posterior intra-orbital sections over three 5 mm slices or more with sparing of the anterior portion. One patient with unilateral visual loss had increased signal only on the affected side. Brain MRI was normal, in marked contrast to the findings in clinically isolated optic neuritis in which multiple white matter lesions are seen in the majority. Images PMID:2732742

  7. Magnetic resonance imaging of optic nerve

    PubMed Central

    Gala, Foram

    2015-01-01

    Optic nerves are the second pair of cranial nerves and are unique as they represent an extension of the central nervous system. Apart from clinical and ophthalmoscopic evaluation, imaging, especially magnetic resonance imaging (MRI), plays an important role in the complete evaluation of optic nerve and the entire visual pathway. In this pictorial essay, the authors describe segmental anatomy of the optic nerve and review the imaging findings of various conditions affecting the optic nerves. MRI allows excellent depiction of the intricate anatomy of optic nerves due to its excellent soft tissue contrast without exposure to ionizing radiation, better delineation of the entire visual pathway, and accurate evaluation of associated intracranial pathologies. PMID:26752822

  8. Chest magnetic resonance imaging: a protocol suggestion*

    PubMed Central

    Hochhegger, Bruno; de Souza, Vinícius Valério Silveira; Marchiori, Edson; Irion, Klaus Loureiro; Souza Jr., Arthur Soares; Elias Junior, Jorge; Rodrigues, Rosana Souza; Barreto, Miriam Menna; Escuissato, Dante Luiz; Mançano, Alexandre Dias; Araujo Neto, César Augusto; Guimarães, Marcos Duarte; Nin, Carlos Schuler; Santos, Marcel Koenigkam; Silva, Jorge Luiz Pereira e

    2015-01-01

    In the recent years, with the development of ultrafast sequences, magnetic resonance imaging (MRI) has been established as a valuable diagnostic modality in body imaging. Because of improvements in speed and image quality, MRI is now ready for routine clinical use also in the study of pulmonary diseases. The main advantage of MRI of the lungs is its unique combination of morphological and functional assessment in a single imaging session. In this article, the authors review most technical aspects and suggest a protocol for performing chest MRI. The authors also describe the three major clinical indications for MRI of the lungs: staging of lung tumors; evaluation of pulmonary vascular diseases; and investigation of pulmonary abnormalities in patients who should not be exposed to radiation. PMID:26811555

  9. Magnetic resonance imaging of prostate cancer.

    PubMed

    Guneyli, Serkan; Erdem, Cemile Zuhal; Erdem, Lutfi Oktay

    2016-01-01

    Prostate cancer is one of the causes of cancer-related deaths. Multiparametric magnetic resonance imaging (MRI) provides the best soft tissue resolution and plays an important role in the management of prostate cancer patients. It is the recommended imaging modality for patients with prostate cancer, and it is clinically indicated for diagnosis, staging, tumor localization, detection of tumor aggressiveness, follow-up, and MRI-guided interventions. Multiparametric MRI includes T1- and high-resolution T2-weighted imaging, diffusion-weighted imaging, and dynamic contrast-enhanced MRI. We evaluated MR images of patients with prostate cancer who underwent multiparametric endorectal MRI on a 3.0-T scanner and presented demonstrative images. PMID:27317204

  10. Magnetic resonance imaging of experimental cerebral oedema.

    PubMed Central

    Barnes, D; McDonald, W I; Tofts, P S; Johnson, G; Landon, D N

    1986-01-01

    Triethyl tin(TET)-induced cerebral oedema has been studied in cats by magnetic resonance imaging (MRI), and the findings correlated with the histology and fine structure of the cerebrum following perfusion-fixation. MRI is a sensitive technique for detecting cerebral oedema, and the distribution and severity of the changes correlate closely with the morphological abnormalities. The relaxation times, T1 and T2 increase progressively as the oedema develops, and the proportional increase in T2 is approximately twice that in T1. Analysis of the magnetisation decay curves reveals slowly-relaxing and rapidly-relaxing components which probably correspond to oedema fluid and intracellular water respectively. The image appearances taken in conjunction with relaxation data provide a basis for determining the nature of the oedema in vivo. Images PMID:3806109

  11. Magnetic resonance imaging of heterotaxis syndrome.

    PubMed

    Stoeckelhuber, Beate M; Eckey, Thomas; Buchholz, Michael; Kapsimalakou, Smaragda; Stoeckelhuber, Mechthild

    2008-12-20

    Failure to establish normal left-right body axis (LRA) formation during embryogenesis results in heterotaxis, a multi-malformation syndrome. We report on a 20-year-old young woman who presented to the emergency room with upper abdominal pain. On chest X-ray, dextrocardia was noted. Ultrasound was inconclusive. Barium studies demonstrated non-rotation of the intestine. Magnetic resonance imaging (MRI) of the abdomen confirmed heterotaxis with abnormal arrangement of abdominal organs and vasculature. This is the first radiographic description of LRA in MRI. It provides a unique contribution to the wide morphological variety of lateralization defects in a single examination within 15 min and without the risks of ionizing radiation. In addition, a literature overview over the genetic aspects, broad morphological spectrum, and possible therapeutic consequences is given. PMID:18835766

  12. Magnetic resonance imaging of pancreatitis: An update

    PubMed Central

    Manikkavasakar, Sriluxayini; AlObaidy, Mamdoh; Busireddy, Kiran K; Ramalho, Miguel; Nilmini, Viragi; Alagiyawanna, Madhavi; Semelka, Richard C

    2014-01-01

    Magnetic resonance (MR) imaging plays an important role in the diagnosis and staging of acute and chronic pancreatitis and may represent the best imaging technique in the setting of pancreatitis due to its unmatched soft tissue contrast resolution as well as non-ionizing nature and higher safety profile of intravascular contrast media, making it particularly valuable in radiosensitive populations such as pregnant patients, and patients with recurrent pancreatitis requiring multiple follow-up examinations. Additional advantages include the ability to detect early forms of chronic pancreatitis and to better differentiate adenocarcinoma from focal chronic pancreatitis. This review addresses new trends in clinical pancreatic MR imaging emphasizing its role in imaging all types of acute and chronic pancreatitis, pancreatitis complications and other important differential diagnoses that mimic pancreatitis. PMID:25356038

  13. Safety of magnetic resonance contrast media.

    PubMed

    Runge, V M

    2001-08-01

    Intravenous contrast media, specifically the gadolinium chelates, are well accepted for use in the clinical practice of magnetic resonance imaging. The gadolinium chelates are considered to be very safe and lack (in intravenous use) the nephrotoxicity found with iodinated contrast media. Minor adverse reactions, including nausea and hives, occur in a low percentage of cases. The four agents currently available in the United States cannot be differentiated on the basis of these adverse reactions. Severe anaphylactoid reactions are also known to occur with all agents, although these are uncommon. This review discusses the safety issues involved with intravenous administration of the gadolinium chelates and off-label use. The latter is common in clinical practice and permits broader application of these agents. PMID:11687717

  14. Molecular magnetic resonance imaging in cancer.

    PubMed

    Haris, Mohammad; Yadav, Santosh K; Rizwan, Arshi; Singh, Anup; Wang, Ena; Hariharan, Hari; Reddy, Ravinder; Marincola, Francesco M

    2015-01-01

    The ability to identify key biomolecules and molecular changes associated with cancer malignancy and the capacity to monitor the therapeutic outcome against these targets is critically important for cancer treatment. Recent developments in molecular imaging based on magnetic resonance (MR) techniques have provided researchers and clinicians with new tools to improve most facets of cancer care. Molecular imaging is broadly described as imaging techniques used to detect molecular signature at the cellular and gene expression levels. This article reviews both established and emerging molecular MR techniques in oncology and discusses the potential of these techniques in improving the clinical cancer care. It also discusses how molecular MR, in conjunction with other structural and functional MR imaging techniques, paves the way for developing tailored treatment strategies to enhance cancer care. PMID:26394751

  15. Fetal Cerebral Magnetic Resonance Imaging Beyond Morphology.

    PubMed

    Jakab, András; Pogledic, Ivana; Schwartz, Ernst; Gruber, Gerlinde; Mitter, Christian; Brugger, Peter C; Langs, Georg; Schöpf, Veronika; Kasprian, Gregor; Prayer, Daniela

    2015-12-01

    The recent technological advancement of fast magnetic resonance imaging (MRI) sequences allowed the inclusion of diffusion tensor imaging, functional MRI, and proton MR spectroscopy in prenatal imaging protocols. These methods provide information beyond morphology and hold the key to improving several fields of human neuroscience and clinical diagnostics. Our review introduces the fundamental works that enabled these imaging techniques, and also highlights the most recent contributions to this emerging field of prenatal diagnostics, such as the structural and functional connectomic approach. We introduce the advanced image processing approaches that are extensively used to tackle fetal or maternal movement-related image artifacts, and which are necessary for the optimal interpretation of such imaging data. PMID:26614130

  16. [Prostate biopsy under magnetic resonance imaging guidance].

    PubMed

    Kuplevatskiy, V I; CherkashiN, M A; Roshchin, D A; Berezina, N A; Vorob'ev, N A

    2016-01-01

    Prostate cancer (PC) is one of the most important problems in modern oncology. According to statistical data, PC ranks second in the cancer morbidity structure in the Russian Federation and developed countries and its prevalence has been progressively increasing over the past decade. A need for early diagnosis and maximally accurate morphological verification of the diagnosis in difficult clinical cases (inconvenient tumor location for standard transrectal biopsy; gland scarring changes concurrent with prostatitis and hemorrhage; threshold values of prostate-specific antigen with unclear changes in its doubling per unit time; suspicion of biochemical recurrence or clinical tumor progression after special treatment) leads to revised diagnostic algorithms and clinically introduced new high-tech invasive diagnostic methods. This paper gives the first analysis of literature data on Russian practice using one of the new methods to verify prostate cancer (transrectal prostate cancer under magnetic resonance imaging (MRI) guidance). The have sought the 1995-2015 data in the MEDLINE and Pubmed. PMID:27192773

  17. Magnetic Resonance Imaging for Perianal Fistula.

    PubMed

    Tolan, Damian J M

    2016-08-01

    Perianal fistulas and other inflammatory diseases of the anus and perianal soft tissues are a cause of substantial morbidity, and are a major part of the practice of any colorectal surgeon. Magnetic resonance imaging (MRI) has a key role in the assessment of patients for the extent of fistulizing Crohn disease, complications related to fistulas, and to assist in confirming the diagnosis or proposing an alternative. Technique is critical and in particular, the selection of sequences for diagnosis and characterization of abnormalities with the main choices being between standard anatomical sequences (T1 or T2), assessing for edema (FS T2 or STIR), assessing abnormal contrast enhancement (FS T1), and assessing for abnormal diffusion or a combination of these. Guidance on MRI sequence selection, classification of fistulas, the current guidance on the role of MRI in assessing patients, and advice on how to provide useful structured reports, as well as how to detect complications of perianal sepsis are included. PMID:27342895

  18. Two-dimensional nuclear magnetic resonance petrophysics.

    PubMed

    Sun, Boqin; Dunn, Keh-Jim

    2005-02-01

    Two-dimensional nuclear magnetic resonance (2D NMR) opens a wide area for exploration in petrophysics and has significant impact to petroleum logging technology. When there are multiple fluids with different diffusion coefficients saturated in a porous medium, this information can be extracted and clearly delineated from CPMG measurements of such a system either using regular pulsing sequences or modified two window sequences. The 2D NMR plot with independent variables of T2 relaxation time and diffusion coefficient allows clear separation of oil and water signals in the rocks. This 2D concept can be extended to general studies of fluid-saturated porous media involving other combinations of two or more independent variables, such as chemical shift and T1/T2 relaxation time (reflecting pore size), proton population and diffusion contrast, etc. PMID:15833623

  19. Magnetic Earth Ionosphere Resonant Frequencies (MEIRF) project

    NASA Technical Reports Server (NTRS)

    Spaniol, Craig

    1993-01-01

    The West Virginia State College Community College Division NASA Magnetic Earth Ionosphere Resonant Frequencies (MEIRF) study is described. During this contract period, the two most significant and professionally rewarding events were the presentation of the research activity at the Sir Isaac Newton Conference in St. Petersburg, Russia, and the second Day of Discovery Conference, focusing on economic recovery in West Virginia. An active antenna concept utilizing a signal feedback principle similar to regenerative receivers used in early radio was studied. The device has potential for ELF research and other commercial applications for improved signal reception. Finally, work continues to progress on the development of a prototype monitoring station. Signal monitoring, data display, and data storage are major areas of activity. In addition, we plan to continue our dissemination of research activity through presentations at seminars and other universities.

  20. The magnetic resonance imaging-linac system.

    PubMed

    Lagendijk, Jan J W; Raaymakers, Bas W; van Vulpen, Marco

    2014-07-01

    The current image-guided radiotherapy systems are suboptimal in the esophagus, pancreas, kidney, rectum, lymph node, etc. These locations in the body are not easily accessible for fiducials and cannot be visualized sufficiently on cone-beam computed tomographies, making daily patient set-up prone to geometrical uncertainties and hinder dose optimization. Additional interfraction and intrafraction uncertainties for those locations arise from motion with breathing and organ filling. To allow real-time imaging of all patient tumor locations at the actual treatment position a fully integrated 1.5-T, diagnostic quality, magnetic resonance imaging with a 6-MV linear accelerator is presented. This system must enable detailed dose painting at all body locations. PMID:24931095

  1. In vivo nuclear magnetic resonance imaging

    NASA Technical Reports Server (NTRS)

    Leblanc, A.; Evans, H.; Bryan, R. N.; Johnson, P.; Schonfeld, E.; Jhingran, S. G.

    1984-01-01

    A number of physiological changes have been demonstrated in bone, muscle and blood after exposure of humans and animals to microgravity. Determining mechanisms and the development of effective countermeasures for long duration space missions is an important NASA goal. The advent of tomographic nuclear magnetic resonance imaging (NMR or MRI) gives NASA a way to greatly extend early studies of this phenomena in ways not previously possible; NMR is also noninvasive and safe. NMR provides both superb anatomical images for volume assessments of individual organs and quantification of chemical/physical changes induced in the examined tissues. The feasibility of NMR as a tool for human physiological research as it is affected by microgravity is demonstrated. The animal studies employed the rear limb suspended rat as a model of mucle atrophy that results from microgravity. And bedrest of normal male subjects was used to simulate the effects of microgravity on bone and muscle.

  2. Nuclear magnetic resonance imaging in medicine

    PubMed Central

    McKinstry, C S

    1986-01-01

    Using the technique of nuclear magnetic resonance (NMR, MR, MRI), the first images displaying pathology in humans were published in 1980.1 Since then, there has been a rapid extension in the use of the technique, with an estimated 225 machines in use in the USA at the end of 1985.2 Considerable enthusiasm has been expressed for this new imaging technique,3 although awareness of its high cost in the present economic climate has led to reservations being expressed in other quarters.2 The aim of this article is to give an outline of the present state of NMR, and indicate some possible future developments. ImagesFig 1Fig 2Fig 3(a)Fig 3 (b)Fig 4Fig 5Fig 6Fig 7 (a)Fig 7 (b)Fig 8Fig 9Fig 10 PMID:3811023

  3. [Nuclear magnetic resonance in ischemic cardiopathy].

    PubMed

    Meave, Aloha

    2007-01-01

    Nuclear magnetic resonance is the "gold standard" technique to quantify the ventricular volume, the ejection fraction, and the myocardial mass. In patients suffering from ischemic cardiopathy, the ejection fraction is the most important prognostic parameter, even above from lessoned arteries index. An adequate diagnose between a non-viable and a viable myocardium is of great importance in the therapeutic approach for ischemic cardiopathy. By administrating a paramagnetic contrast media named gadolinium, fist pass and late-reinforcement techniques, are applied. With these, it is possible to evaluate the perfusion as well as necrotic areas. In order to identify sub-endocardium ischemia, drugs such as adenosine and dipiridamol, are employed as vasodilators. This technique allows the definition of reinforcement extension, being sub-endocardiac, which is an ailment which affects 50% of the myocardium depth, or even, transmural compromise. PMID:18938717

  4. Stem cell labeling for magnetic resonance imaging.

    PubMed

    Himmelreich, Uwe; Hoehn, Mathias

    2008-01-01

    In vivo applications of cells for the monitoring of their cell dynamics increasingly use non-invasive magnetic resonance imaging. This imaging modality allows in particular to follow the migrational activity of stem cells intended for cell therapy strategies. All these approaches require the prior labeling of the cells under investigation for excellent contrast against the host tissue background in the imaging modality. The present review discusses the various routes of cell labeling and describes the potential to observe both cell localization and their cell-specific function in vivo. Possibilities for labeling strategies, pros and cons of various contrast agents are pointed out while potential ambiguities or problems of labeling strategies are emphasized. PMID:18465447

  5. Nuclear magnetic resonance imaging of the spine

    SciTech Connect

    Modic, M.T.; Weinstein, M.A.; Pavlicek, W.; Starnes, D.L.; Duchesneau, P.M.; Boumphrey, F.; Hardy, R.J. Jr.

    1984-01-01

    Forty subjects were examined to determine the accuracy and clinical usefulness of nuclear magnetic resonance (NMR) examination of the spine. The NMR images were compared with plain radiographs, high-resolution computed tomograms, and myelograms. The study included 15 patients with normal spinal cord anatomy and 25 patients whose pathological conditions included canal stenosis, herniated discs, metastatic tumors, primary cord tumor, trauma, Chiari malformations, syringomyelia, and developmental disorders. Saturation recovery images were best in differentiating between soft tissue and cerebrospinal fluid. NMR was excellent for the evaluation of the foramen magnum region and is presently the modality of choice for the diagnosis of syringomyelia and Chiari malformation. NMR was accurate in diagnosing spinal cord trauma and spinal canal block.

  6. Chronic subdural hematoma: demonstration by magnetic resonance

    SciTech Connect

    Sipponen, J.T.; Sepponen, R.E.; Sivula, A.

    1984-01-01

    The ability of magnetic resonance (MR) to identify intracranial hematomas was tested in five patients with clinical and computed tomographic signs of chronic subdural hematoma. The extracerebral collections were displayed as a zone of bright intensity using the T1-weighted inversion recovery (IR 1500/400) sequence, reflecting the lesions' short T1 relaxation times. The collections also showed high intensity using the spin echo (SE) sequence, with a longer delay of 100ms and 160ms, reflecting the long T2 relaxation time. The spin echo sequence with a repetition time of 500ms and an echo delay of 160ms (SE 500/160) almost effaced other structures in the image, thus increasing the specificity of this pulse scheme for detection of chronic blood collections. Although in two of the five patients the subdural hematomas were in the isodense CT phase, all were easily visualized with MR.

  7. Magnetic Resonance Imaging of the Knee

    PubMed Central

    Hash, Thomas W.

    2013-01-01

    Context: Magnetic resonance imaging (MRI) affords high-resolution visualization of the soft tissue structures (menisci, ligaments, cartilage, etc) and bone marrow of the knee. Evidence Acquisition: Pertinent clinical and research articles in the orthopaedic and radiology literature over the past 30 years using PubMed. Results: Ligament tears can be accurately assessed with MRI, but distinguishing partial tears from ruptures of the anterior cruciate ligament (ACL) can be challenging. Determining the extent of a partial tear is often extremely difficult to accurately assess. The status of the posterolateral corner structures, menisci, and cartilage can be accurately evaluated, although limitations in the evaluation of certain structures exist. Patellofemoral joint, marrow, tibiofibular joint, and synovial pathology can supplement physical examination findings and provide definitive diagnosis. Conclusions: MRI provides an accurate noninvasive assessment of knee pathology. PMID:24381701

  8. Simplifying cardiovascular magnetic resonance pulse sequence terminology.

    PubMed

    Friedrich, Matthias G; Bucciarelli-Ducci, Chiara; White, James A; Plein, Sven; Moon, James C; Almeida, Ana G; Kramer, Christopher M; Neubauer, Stefan; Pennell, Dudley J; Petersen, Steffen E; Kwong, Raymond Y; Ferrari, Victor A; Schulz-Menger, Jeanette; Sakuma, Hajime; Schelbert, Erik B; Larose, Éric; Eitel, Ingo; Carbone, Iacopo; Taylor, Andrew J; Young, Alistair; de Roos, Albert; Nagel, Eike

    2014-01-01

    We propose a set of simplified terms to describe applied Cardiovascular Magnetic Resonance (CMR) pulse sequence techniques in clinical reports, scientific articles and societal guidelines or recommendations. Rather than using various technical details in clinical reports, the description of the technical approach should be based on the purpose of the pulse sequence. In scientific papers or other technical work, this should be followed by a more detailed description of the pulse sequence and settings. The use of a unified set of widely understood terms would facilitate the communication between referring physicians and CMR readers by increasing the clarity of CMR reports and thus improve overall patient care. Applied in research articles, its use would facilitate non-expert readers' understanding of the methodology used and its clinical meaning. PMID:25551695

  9. Magnetic resonance imaging of pancreatitis: an update.

    PubMed

    Manikkavasakar, Sriluxayini; AlObaidy, Mamdoh; Busireddy, Kiran K; Ramalho, Miguel; Nilmini, Viragi; Alagiyawanna, Madhavi; Semelka, Richard C

    2014-10-28

    Magnetic resonance (MR) imaging plays an important role in the diagnosis and staging of acute and chronic pancreatitis and may represent the best imaging technique in the setting of pancreatitis due to its unmatched soft tissue contrast resolution as well as non-ionizing nature and higher safety profile of intravascular contrast media, making it particularly valuable in radiosensitive populations such as pregnant patients, and patients with recurrent pancreatitis requiring multiple follow-up examinations. Additional advantages include the ability to detect early forms of chronic pancreatitis and to better differentiate adenocarcinoma from focal chronic pancreatitis. This review addresses new trends in clinical pancreatic MR imaging emphasizing its role in imaging all types of acute and chronic pancreatitis, pancreatitis complications and other important differential diagnoses that mimic pancreatitis. PMID:25356038

  10. Magnetic resonance imaging after exposure to microgravity

    NASA Technical Reports Server (NTRS)

    Leblanc, Adrian

    1993-01-01

    A number of physiological changes were demonstrated in bone, muscle, and blood from exposure of humans and animals to microgravity. Determining mechanisms and the development of effective countermeasures for long-duration space missions is an important NASA goal. Historically, NASA has had to rely on tape measures, x-ray, and metabolic balance studies with collection of excreta and blood specimens to obtain this information. The development of magnetic resonance imaging (MRI) offers the possibility of greatly extending these early studies in ways not previously possible; MRI is also non-invasive and safe; i.e., no radiation exposure. MRI provides both superb anatomical images for volume measurements of individual structures and quantification of chemical/physical changes induced in the examined tissues. This investigation will apply MRI technology to measure muscle, intervertebral disc, and bone marrow changes resulting from exposure to microgravity.

  11. Geochemical Controls on Nuclear Magnetic Resonance Measurements

    SciTech Connect

    Knight, Rosemary; Prasad, Manika; Keating, Kristina

    2003-11-11

    OAK-B135 Our research objectives are to determine, through an extensive set of laboratory experiments, the effect of the specific mineralogic form of iron and the effect of the distribution of iron on proton nuclear magnetic resonance (NMR) relaxation mechanisms. In the first nine months of this project, we have refined the experimental procedures to be used in the acquisition of the laboratory NMR data; have ordered, and conducted preliminary measurements on, the sand samples to be used in the experimental work; and have revised and completed the theoretical model to use in this project. Over the next year, our focus will be on completing the first phase of the experimental work where the form and distribution of the iron in the sands in varied.

  12. Magnetic Resonance Studies of Energy Storage Materials

    NASA Astrophysics Data System (ADS)

    Vazquez Reina, Rafael

    In today's society there is high demand to have access to energy for portable devices in different forms. Capacitors with high performance in small package to achieve high charge/discharge rates, and batteries with their ability to store electricity and make energy mobile are part of this demand. The types of internal dielectric material strongly affect the characteristics of a capacitor, and its applications. In a battery, the choice of the electrolyte plays an important role in the Solid Electrolyte Interphase (SEI) formation, and the cathode material for high output voltage. Electron Paramagnetic Resonance (EPR) and Nuclear Magnetic Resonance (NMR) spectroscopy are research techniques that exploit the magnetic properties of the electron and certain atomic nuclei to determine physical and chemical properties of the atoms or molecules in which they are contained. Both EPR and NMR spectroscopy technique can yield meaningful structural and dynamic information. Three different projects are discussed in this dissertation. First, High energy density capacitors where EPR measurements described herein provide an insight into structural and chemical differences in the dielectric material of a capacitor. Next, as the second project, Electrolyte solutions where an oxygen-17 NMR study has been employed to assess the degree of preferential solvation of Li+ ions in binary mixtures of EC (ethylene carbonate) and DMC (dimethyl carbonate) containing LiPF6 (lithium hexafluo-rophosphate) which may be ultimately related to the SEI formation mechanism. The third project was to study Bismuth fluoride as cathode material for rechargeable batteries. The objective was to study 19F and 7Li MAS NMR of some nanocomposite cathode materials as a conversion reaction occurring during lithiation and delithation of the BiF3/C nanocomposite.

  13. Could magnetic resonance provide in vivo histology?

    PubMed Central

    Dominietto, Marco; Rudin, Markus

    2014-01-01

    The diagnosis of a suspected tumor lesion faces two basic problems: detection and identification of the specific type of tumor. Radiological techniques are commonly used for the detection and localization of solid tumors. Prerequisite is a high intrinsic or enhanced contrast between normal and neoplastic tissue. Identification of the tumor type is still based on histological analysis. The result depends critically on the sampling sites, which given the inherent heterogeneity of tumors, constitutes a major limitation. Non-invasive in vivo imaging might overcome this limitation providing comprehensive three-dimensional morphological, physiological, and metabolic information as well as the possibility for longitudinal studies. In this context, magnetic resonance based techniques are quite attractive since offer at the same time high spatial resolution, unique soft tissue contrast, good temporal resolution to study dynamic processes and high chemical specificity. The goal of this paper is to review the role of magnetic resonance techniques in characterizing tumor tissue in vivo both at morphological and physiological levels. The first part of this review covers methods, which provide information on specific aspects of tumor phenotypes, considered as indicators of malignancy. These comprise measurements of the inflammatory status, neo-vascular physiology, acidosis, tumor oxygenation, and metabolism together with tissue morphology. Even if the spatial resolution is not sufficient to characterize the tumor phenotype at a cellular level, this multiparametric information might potentially be used for classification of tumors. The second part discusses mathematical tools, which allow characterizing tissue based on the acquired three-dimensional data set. In particular, methods addressing tumor heterogeneity will be highlighted. Finally, we address the potential and limitation of using MRI as a tool to provide in vivo tissue characterization. PMID:24454320

  14. Computed tomography and magnetic resonance findings in lipoid pneumonia.

    PubMed Central

    Bréchot, J M; Buy, J N; Laaban, J P; Rochemaure, J

    1991-01-01

    A case of exogenous lipoid pneumonia was documented by computed tomography and magnetic resonance imaging. Although strongly suggesting the presence of fat on T1 weighted images, magnetic resonance does not produce images specific for this condition. Computed tomography is the best imaging modality for its diagnosis. Images PMID:1750024

  15. 21 CFR 892.1000 - Magnetic resonance diagnostic device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Magnetic resonance diagnostic device. 892.1000 Section 892.1000 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1000 Magnetic resonance...

  16. 21 CFR 892.1000 - Magnetic resonance diagnostic device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Magnetic resonance diagnostic device. 892.1000 Section 892.1000 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1000 Magnetic resonance...

  17. Compact electrically detected magnetic resonance setup

    SciTech Connect

    Eckardt, Michael Harneit, Wolfgang; Behrends, Jan; Münter, Detlef

    2015-04-15

    Electrically detected magnetic resonance (EDMR) is a commonly used technique for the study of spin-dependent transport processes in semiconductor materials and electro-optical devices. Here, we present the design and implementation of a compact setup to measure EDMR, which is based on a commercially available benchtop electron paramagnetic resonance (EPR) spectrometer. The electrical detection part uses mostly off-the-shelf electrical components and is thus highly customizable. We present a characterization and calibration procedure for the instrument that allowed us to quantitatively reproduce results obtained on a silicon-based reference sample with a “large-scale” state-of-the-art instrument. This shows that EDMR can be used in novel contexts relevant for semiconductor device fabrication like clean room environments and even glove boxes. As an application example, we present data on a class of environment-sensitive objects new to EDMR, semiconducting organic microcrystals, and discuss similarities and differences to data obtained for thin-film devices of the same molecule.

  18. Selectivity in multiple quantum nuclear magnetic resonance

    SciTech Connect

    Warren, W.S.

    1980-11-01

    The observation of multiple-quantum nuclear magnetic resonance transitions in isotropic or anisotropic liquids is shown to give readily interpretable information on molecular configurations, rates of motional processes, and intramolecular interactions. However, the observed intensity of high multiple-quantum transitions falls off dramatically as the number of coupled spins increases. The theory of multiple-quantum NMR is developed through the density matrix formalism, and exact intensities are derived for several cases (isotropic first-order systems and anisotropic systems with high symmetry) to shown that this intensity decrease is expected if standard multiple-quantum pulse sequences are used. New pulse sequences are developed which excite coherences and produce population inversions only between selected states, even though other transitions are simultaneously resonant. One type of selective excitation presented only allows molecules to absorb and emit photons in groups of n. Coherent averaging theory is extended to describe these selective sequences, and to design sequences which are selective to arbitrarily high order in the Magnus expansion. This theory and computer calculations both show that extremely good selectivity and large signal enhancements are possible.

  19. Magnetic resonance characterization of silicon nanowires

    NASA Astrophysics Data System (ADS)

    Fanciulli, Marco; Belli, Matteo; Vellei, Antonio; Canevali, Carmen; Rotta, Davide; Paleari, Stefano; Basini, Martina

    2012-02-01

    Silicon nanowires (SiNWs) have been extensively investigated in the last decades. The interest in these nanostructures stems from both fundamental and applied research motivations. The functional properties of one- and zero-dimensional silicon structures are significantly different, at least below a certain critical dimension, from those well known in the bulk. The key and peculiar functional properties of SiNWs find applications in nanoelectronics, classical and quantum information processing and storage, optoelectronics, photovoltaics, thermoelectric, battery technology, nano-biotechnology, and neuroelectronics. We report our work on the characterization by continuous wave (CW) and pulse electron spin resonance (CW, FT-EPR) and electrically detected magnetic resonance (EDMR) measurements of silicon nanowires (SiNWs) produced by different top-down processes. SiNWs were fabricated starting from SOI wafers using standard e-beam lithography and anisotropic wet etching or by metal-assisted chemical etching. Further oxidation was used to reduce the wire cross section. Different EDMR implementations were used to address the electronic wave function of donors (P, As) and to characterize point defects at the SiNWs/SiO2 interface.

  20. Compact electrically detected magnetic resonance setup

    NASA Astrophysics Data System (ADS)

    Eckardt, Michael; Behrends, Jan; Münter, Detlef; Harneit, Wolfgang

    2015-04-01

    Electrically detected magnetic resonance (EDMR) is a commonly used technique for the study of spin-dependent transport processes in semiconductor materials and electro-optical devices. Here, we present the design and implementation of a compact setup to measure EDMR, which is based on a commercially available benchtop electron paramagnetic resonance (EPR) spectrometer. The electrical detection part uses mostly off-the-shelf electrical components and is thus highly customizable. We present a characterization and calibration procedure for the instrument that allowed us to quantitatively reproduce results obtained on a silicon-based reference sample with a "large-scale" state-of-the-art instrument. This shows that EDMR can be used in novel contexts relevant for semiconductor device fabrication like clean room environments and even glove boxes. As an application example, we present data on a class of environment-sensitive objects new to EDMR, semiconducting organic microcrystals, and discuss similarities and differences to data obtained for thin-film devices of the same molecule.

  1. Rotating-frame gradient fields for magnetic resonance imaging and nuclear magnetic resonance in low fields

    DOEpatents

    Bouchard, Louis-Serge; Pines, Alexander; Demas, Vasiliki

    2014-01-21

    A system and method for Fourier encoding a nuclear magnetic resonance (NMR) signal is disclosed. A static magnetic field B.sub.0 is provided along a first direction. An NMR signal from the sample is Fourier encoded by applying a rotating-frame gradient field B.sub.G superimposed on the B.sub.0, where the B.sub.G comprises a vector component rotating in a plane perpendicular to the first direction at an angular frequency .omega.in a laboratory frame. The Fourier-encoded NMR signal is detected.

  2. The future of magnetic resonance-based techniques in neurology.

    PubMed

    2001-01-01

    Magnetic resonance techniques have become increasingly important in neurology for defining: 1. brain, spinal cord and peripheral nerve or muscle structure; 2. pathological changes in tissue structures and properties; and 3. dynamic patterns of functional activation of the brain. New applications have been driven in part by advances in hardware, particularly improvements in magnet and gradient coil design. New imaging strategies allow novel approaches to contrast with, for example, diffusion imaging, magnetization transfer imaging, perfusion imaging and functional magnetic resonance imaging. In parallel with developments in hardware and image acquisition have been new approaches to image analysis. These have allowed quantitative descriptions of the image changes to be used for a precise, non-invasive definition of pathology. With the increasing capabilities and specificity of magnetic resonance techniques it is becoming more important that the neurologist is intimately involved in both the selection of magnetic resonance studies for patients and their interpretation. There is a need for considerably improved access to magnetic resonance technology, particularly in the acute or intensive care ward and in the neurosurgical theatre. This report illustrates several key developments. The task force concludes that magnetic resonance imaging is a major clinical tool of growing significance and offers recommendations for maximizing the potential future for magnetic resonance techniques in neurology. PMID:11509077

  3. Plasma-induced magnetic responses during nonlinear dynamics of magnetic islands due to resonant magnetic perturbations

    SciTech Connect

    Nishimura, Seiya

    2014-12-15

    Resonant magnetic perturbations (RMPs) produce magnetic islands in toroidal plasmas. Self-healing (annihilation) of RMP-induced magnetic islands has been observed in helical systems, where a possible mechanism of the self-healing is shielding of RMP penetration by plasma flows, which is well known in tokamaks. Thus, fundamental physics of RMP shielding is commonly investigated in both tokamaks and helical systems. In order to check this mechanism, detailed informations of magnetic island phases are necessary. In experiments, measurement of radial magnetic responses is relatively easy. In this study, based on a theoretical model of rotating magnetic islands, behavior of radial magnetic fields during the self-healing is investigated. It is confirmed that flips of radial magnetic fields are typically observed during the self-healing. Such behavior of radial magnetic responses is also observed in LHD experiments.

  4. Cardiac imaging using gated magnetic resonance

    SciTech Connect

    Lanzer, P.; Botvinick, E.H.; Schiller, N.B.

    1984-01-01

    To overcome the limitations of magnetic resonance (MR) cardiac imaging using nongated data acquisition, three methods for acquiring a gating signal, which could be applied in the presence of a magnetic field, were tested; an air-filled plethysmograph, a laser-Doppler capillary perfusion flowmeter, and an electrocardiographic gating device. The gating signal was used for timing of MR imaging sequences (IS). Application of each gating method yielded significant improvements in structural MR image resolution of the beating heart, although with both plethysmography and laser-Doppler velocimetry it was difficult to obtain cardiac images from the early portion of the cardiac cycle due to an intrinsic delay between the ECG R wave and peripheral detection of the gating signal. Variations in the temporal relationship between the R wave and plethysmographic and laser-Doppler signals produced inconsistencies in the timing of IS. Since the ECG signal is virtually free of these problems, the preferable gating technique is IS synchronization with an electrocardiogram. The gated images acquired with this method provide sharp definition of internal cardiac morphology and can be temporarily referenced to end diastole and end systole or intermediate points.

  5. Multi-dimensionally encoded magnetic resonance imaging

    PubMed Central

    Lin, Fa-Hsuan

    2013-01-01

    Magnetic resonance imaging typically achieves spatial encoding by measuring the projection of a q-dimensional object over q-dimensional spatial bases created by linear spatial encoding magnetic fields (SEMs). Recently, imaging strategies using nonlinear SEMs have demonstrated potential advantages for reconstructing images with higher spatiotemporal resolution and reducing peripheral nerve stimulation. In practice, nonlinear SEMs and linear SEMs can be used jointly to further improve the image reconstruction performance. Here we propose the multi-dimensionally encoded (MDE) MRI to map a q-dimensional object onto a p-dimensional encoding space where p > q. MDE MRI is a theoretical framework linking imaging strategies using linear and nonlinear SEMs. Using a system of eight surface SEM coils with an eight-channel RF coil array, we demonstrate the five-dimensional MDE MRI for a two-dimensional object as a further generalization of PatLoc imaging and O-space imaging. We also present a method of optimizing spatial bases in MDE MRI. Results show that MDE MRI with a higher dimensional encoding space can reconstruct images more efficiently and with a smaller reconstruction error when the k-space sampling distribution and the number of samples are controlled. PMID:22926830

  6. Contrast media in cardiovascular magnetic resonance.

    PubMed

    Lombardi, Massimo; Aquaro, Giovanni; Favilli, Brunella

    2005-01-01

    Among the available imaging techniques, Magnetic Resonance Imaging (MRI) is gaining an increasing role in the cardiologic setting because its specific properties such as the use of non ionising energies, the natural strong contrast between different tissues, the absence of spatial limitations, the good spatial and temporal resolution, the reduced operator dependency. To further improve the images quality and the histopathologic characterisation of tissues the use of contrast media (molecules containing gadolinium, manganese, iron, dysprosium ions) has been proposed both in the experimental and in the clinical settings. Among these ions gadolinium, which having 7 odd electrons in the external orbit has a strong magnetic momentum, is the most used. Gadolinium by itself is extremely toxic but once it is linked with a chelanting agent such as DTPA (Dietilen-Triamin-Penta-Acetic acid) the resulting complex shows a very low toxicity. The number of Gadolinium based compound is growing together with the use of contrast agents in MRI. These contrast agents are routinely used to perform Magnetic Resonance Angiography (MRA) and to a better definition of several cardiac diseases such as the presence of a intra- or paracardiac mass, the evaluation of myocardial perfusion and the evaluation of viability. Both the latter applications have relevant clinical implications. In fact the assessment of myocardial perfusion is one of the most used approach for detecting inducible myocardial ischemia due to major coronary artery disease or to assess the presence of a microvascular disease. The presence and the extent of viable myocardium is deeply modifying the clinical decision making as this viable tissue can recruit a normal function spontaneously or after revascularisation. Furthermore, the extent of viable myocardium has a strong correlation with negative prognosis. Clinical events are also time related to the detection of viable tissue. These evidences imply that the diagnostic

  7. Microrobotic navigable entities for Magnetic Resonance Targeting.

    PubMed

    Martel, Sylvain

    2010-01-01

    Magnetic Resonance Targeting (MRT) uses MRI for gathering tracking data to determine the position of microscale entities with the goal of guiding them towards a specific target in the body accessible through the vascular network. At full capabilities, a MRT platform designed to treat a human would consist of a clinical MRI scanner running special algorithms and upgraded to provide propulsion gradient up to approximately 400mT/m to enable entities as small as a few tens of micrometers in diameter and containing magnetic nanoparticles (MNP) to be steered at vessel bifurcations based on tracking information. Indeed, using a clinical MRI system, we showed that such single entity with a diameter as small as 15microm is detectable in gradient-echo scans. Among many potential interventions, targeted cancer therapy is a good initial application for such new microrobotic approach since secondary toxicity for the patient could be reduced while increasing therapeutic efficacy using lower dosages. Although many types of such entities are needed to provide a larger set of tools, here, only three initial types designed with different functionalities and for different types of cancer are briefly described. Initially designed for targeted chemo-embolization of liver tumors, the first type known as Therapeutic Magnetic Micro-Carriers (TMMC) consists in its present form of approximately 50 microm PLGA microparticles containing therapeutics and approximately 180 nm FeCo MNP. For the second type, MNP are not only used for propulsion and tracking, but also actuation based on a local elevation of the temperature. In its simplest form, it consists of approxiamtely 20 nm MNP embedded in a thermo-sensitive hydrogel known as PNIPA, allowing additional functionalities such as computer triggered drug release and targeted hyperthermia. The third type initially considered to target colorectal tumors, consists of 1-2 microm MR-trackable and controllable MC-1 Magnetotactic Bacteria (MTB) with

  8. Overhauser-enhanced magnetic resonance elastography.

    PubMed

    Salameh, Najat; Sarracanie, Mathieu; Armstrong, Brandon D; Rosen, Matthew S; Comment, Arnaud

    2016-05-01

    Magnetic resonance elastography (MRE) is a powerful technique to assess the mechanical properties of living tissue. However, it suffers from reduced sensitivity in regions with short T2 and T2 * such as in tissue with high concentrations of paramagnetic iron, or in regions surrounding implanted devices. In this work, we exploit the longer T2 * attainable at ultra-low magnetic fields in combination with Overhauser dynamic nuclear polarization (DNP) to enable rapid MRE at 0.0065 T. A 3D balanced steady-state free precession based MRE sequence with undersampling and fractional encoding was implemented on a 0.0065 T MRI scanner. A custom-built RF coil for DNP and a programmable vibration system for elastography were developed. Displacement fields and stiffness maps were reconstructed from data recorded in a polyvinyl alcohol gel phantom loaded with stable nitroxide radicals. A DNP enhancement of 25 was achieved during the MRE sequence, allowing the acquisition of 3D Overhauser-enhanced MRE (OMRE) images with (1.5 × 2.7 × 9) mm(3) resolution over eight temporal steps and 11 slices in 6 minutes. In conclusion, OMRE at ultra-low magnetic field can be used to detect mechanical waves over short acquisition times. This new modality shows promise to broaden the scope of conventional MRE applications, and may extend the utility of low-cost, portable MRI systems to detect elasticity changes in patients with implanted devices or iron overload. Copyright © 2016 John Wiley & Sons, Ltd. PMID:26915977

  9. Operation of Lanzhou all permanent electron cyclotron resonance ion source No. 2 on 320 kV platform with highly charged ions.

    PubMed

    Lu, W; Li, J Y; Kang, L; Liu, H P; Li, H; Li, J D; Sun, L T; Ma, X W

    2014-02-01

    The 320 kV platform for multi-discipline research with highly charged ions is a heavy ion beam acceleration instrument developed by Institute of Modern Physics, which is dedicated to basic scientific researches such as plasma, atom, material physics, and astrophysics, etc. The platform has delivered ion beams of 400 species for 36,000 h. The average operation time is around 5000 h/year. With the beams provided by the platform, lots of outstanding progresses were made in various research fields. The ion source of the platform is an all-permanent magnet electron cyclotron resonance ion source, LAPECR2 (Lanzhou All Permanent ECR ion source No. 2). The maximum axial magnetic fields are 1.28 T at injection and 1.07 T at extraction, and the radial magnetic field is up to 1.21 T at the inner wall of the plasma chamber. The ion source is capable to produce low, medium, and high charge state gaseous and metallic ion beams, such as H(+), (40)Ar(8+), (129)Xe(30+), (209)Bi(33+), etc. This paper will present the latest result of LAPECR2 and the routine operation status for the high voltage platform. PMID:24593526

  10. Control of Transport-Barrier Relaxations by Resonant Magnetic Perturbations

    SciTech Connect

    Leconte, M.; Beyer, P.; Benkadda, S.

    2009-01-30

    Transport-barrier relaxation oscillations in the presence of resonant magnetic perturbations are investigated using three-dimensional global fluid turbulence simulations from first principles at the edge of a tokamak. It is shown that resonant magnetic perturbations have a stabilizing effect on these relaxation oscillations and that this effect is due mainly to a modification of the pressure profile linked to the presence of both residual magnetic island chains and a stochastic layer.

  11. Quantifying mixing using magnetic resonance imaging.

    PubMed

    Tozzi, Emilio J; McCarthy, Kathryn L; Bacca, Lori A; Hartt, William H; McCarthy, Michael J

    2012-01-01

    Mixing is a unit operation that combines two or more components into a homogeneous mixture. This work involves mixing two viscous liquid streams using an in-line static mixer. The mixer is a split-and-recombine design that employs shear and extensional flow to increase the interfacial contact between the components. A prototype split-and-recombine (SAR) mixer was constructed by aligning a series of thin laser-cut Poly (methyl methacrylate) (PMMA) plates held in place in a PVC pipe. Mixing in this device is illustrated in the photograph in Fig. 1. Red dye was added to a portion of the test fluid and used as the minor component being mixed into the major (undyed) component. At the inlet of the mixer, the injected layer of tracer fluid is split into two layers as it flows through the mixing section. On each subsequent mixing section, the number of horizontal layers is duplicated. Ultimately, the single stream of dye is uniformly dispersed throughout the cross section of the device. Using a non-Newtonian test fluid of 0.2% Carbopol and a doped tracer fluid of similar composition, mixing in the unit is visualized using magnetic resonance imaging (MRI). MRI is a very powerful experimental probe of molecular chemical and physical environment as well as sample structure on the length scales from microns to centimeters. This sensitivity has resulted in broad application of these techniques to characterize physical, chemical and/or biological properties of materials ranging from humans to foods to porous media (1, 2). The equipment and conditions used here are suitable for imaging liquids containing substantial amounts of NMR mobile (1)H such as ordinary water and organic liquids including oils. Traditionally MRI has utilized super conducting magnets which are not suitable for industrial environments and not portable within a laboratory (Fig. 2). Recent advances in magnet technology have permitted the construction of large volume industrially compatible magnets suitable for

  12. Quantifying Mixing using Magnetic Resonance Imaging

    PubMed Central

    Tozzi, Emilio J.; McCarthy, Kathryn L.; Bacca, Lori A.; Hartt, William H.; McCarthy, Michael J.

    2012-01-01

    Mixing is a unit operation that combines two or more components into a homogeneous mixture. This work involves mixing two viscous liquid streams using an in-line static mixer. The mixer is a split-and-recombine design that employs shear and extensional flow to increase the interfacial contact between the components. A prototype split-and-recombine (SAR) mixer was constructed by aligning a series of thin laser-cut Poly (methyl methacrylate) (PMMA) plates held in place in a PVC pipe. Mixing in this device is illustrated in the photograph in Fig. 1. Red dye was added to a portion of the test fluid and used as the minor component being mixed into the major (undyed) component. At the inlet of the mixer, the injected layer of tracer fluid is split into two layers as it flows through the mixing section. On each subsequent mixing section, the number of horizontal layers is duplicated. Ultimately, the single stream of dye is uniformly dispersed throughout the cross section of the device. Using a non-Newtonian test fluid of 0.2% Carbopol and a doped tracer fluid of similar composition, mixing in the unit is visualized using magnetic resonance imaging (MRI). MRI is a very powerful experimental probe of molecular chemical and physical environment as well as sample structure on the length scales from microns to centimeters. This sensitivity has resulted in broad application of these techniques to characterize physical, chemical and/or biological properties of materials ranging from humans to foods to porous media 1, 2. The equipment and conditions used here are suitable for imaging liquids containing substantial amounts of NMR mobile 1H such as ordinary water and organic liquids including oils. Traditionally MRI has utilized super conducting magnets which are not suitable for industrial environments and not portable within a laboratory (Fig. 2). Recent advances in magnet technology have permitted the construction of large volume industrially compatible magnets suitable for

  13. Magnetic Field Gradient Waveform Monitoring for Magnetic Resonance

    NASA Astrophysics Data System (ADS)

    Han, Hui

    Linear magnetic field gradients have played a central role in Magnetic Resonance Imaging (MRI) since Fourier Transform MRI was proposed three decades ago. Their primary function is to encode spatial information into MR signals. Magnetic field gradients are also used to sensitize the image contrast to coherent and/or incoherent motion, to selectively enhance an MR signal, and to minimize image artifacts. Modern MR imaging techniques increasingly rely on the implementation of complex gradient waveforms for the manipulation of spin dynamics. However, gradient system infidelities caused by eddy currents, gradient amplifier imperfections and group delays, often result in image artifacts and other errors (e.g., phase and intensity errors). This remains a critical problem for a wide range of MRI techniques on modern commercial systems, but is of particular concern for advanced MRI pulse sequences. Measuring the real magnetic field gradients, i.e., characterizing eddy currents, is critical to addressing and remedying this problem. Gradient measurement and eddy current calibration are therefore a general topic of importance to the science of MRI. The Magnetic Field Gradient Monitor (MFGM) idea was proposed and developed specifically to meet these challenges. The MFGM method is the heart of this thesis. MFGM methods permit a variety of magnetic field gradient problems to be investigated and systematically remedied. Eddy current effects associated with MR compatible metallic pressure vessels were analyzed, simulated, measured and corrected. The appropriate correction of eddy currents may enable most MR/MRI applications with metallic pressure vessels. Quantitative imaging (1D/2D) with model pressure vessels was successfully achieved by combining image reconstruction with MFGM determined gradient waveform behaviour. Other categories of MR applications with metallic vessels, including diffusion measurement and spin echo SPI T2 mapping, cannot be realized solely by MFGM guided

  14. Tuning Coler Magnetic Current Apparatus with Magneto-Acoustic Resonance

    NASA Astrophysics Data System (ADS)

    Ludwig, Thorsten

    An attempt was made to tune the Coler magnetic current apparatus with the magneto acoustic resonance of the magnetic rods. Measurements with a replica of the famous Coler "Magnetstromapparat" were conducted. In order to tune the acoustic, magnetic and electric resonance circuits of the Coler device the magneto-acoustic resonance was measured with a frequency scan through a function generator and a lock-in amplifier. The frequency generator was powering a driving coil, while the lock-in was connected to a pickup coil. Both coils were placed on a magnetic rod. Resonances were observed up to the 17th harmonic. The quality Q of the observed resonances was 270. To study the magneto-acoustic resonance in the time domain a pair of Permendur rods were employed. The magneto-acoustic resonances of the Permendur rods were observed with an oscilloscope. Spectra of the magneto acoustic resonance were measured for the Permendur rods and for a Coler replica magnet in the frequency range from 25 kHz to 380 kHz. The next step was to bring the resonances of the Permendur rods close together so that they overlap. The 10thharmonic was chosen because it was close to the 180 kHz that Hans Coler related to ferromagnetism. Further more magneto-acoustic coupling between the Permendur rods was studied. Finally the question was explored if Hans Coler converted vacuum fluctuations via magnetic and acoustic resonance into electricity. There is a strong connection between magnetism and quantum field zero point energy (ZPE). An outlook is given on next steps in the experiments to unveil the working mechanism of the Coler magnetic current apparatus.

  15. Ferromagnetic Resonance Studies of Magnetic Recording Media

    NASA Astrophysics Data System (ADS)

    Yu, Yuwu

    1995-01-01

    Angular dependence of maximum remanence (ADMR) and/or x-ray diffraction (XRD) techniques have been used to determine particle orientation distributions for various recording media, including gamma -rm Fe_2O_3, Co- gamma-rm Fe_2O_3, CrO_2, Ba-ferrite, and MP tapes. A distribution of column directions for metal evaporated (ME) tape has been determined from transmission electron microscopy (TEM) pictures. However, the ferromagnetic resonance (FMR) results suggest a much more narrow distribution of magnetic anisotropy directions. For Ba-ferrite tapes, the distribution functions measured by ADMR are consistent with those by XRD if interparticle interactions are accounted for. The predetermined distribution function has been used to fit FMR spectra for the above tapes. Landau-Lifshitz damping constants have been measured with high accuracy for particulate recording media. An excellent correlation has been found between the damping constants and the switching constants for these media. The results suggest that the FMR technique may be useful in predicting the switching speed of particulate recording media. The FMR technique is also useful in looking for methods of increasing the damping constant of recording media. Possible methods of increasing the switching speed of Ba-ferrite media have been studied. The reduction of Ba-ferrite particles in a hydrogen atmosphere increases the damping constant significantly. It is predicted that reduced Ba-ferrite probably switches faster than ordinary Ba-ferrite. Qualitative discussions on the origin of damping for various recording media have been presented within the framework of magnon relaxation theory. The dependence of the damping constant on magnetic properties, such as particle orientation, media coercivity, and particle interactions are also discussed.

  16. Magnetic resonance imaging in cardiac amyloidosis

    SciTech Connect

    O'Donnell, J.K.; Go, R.T.; Bott-Silverman, C.; Feiglin, D.H.; Salcedo, E.; MacIntyre, W.J.

    1984-01-01

    Primary amyloidosis (AL) involves the myocardium in 90% of cases and may present as apparent ischemia, vascular disease, or congestive heart failure. Two-dimensional echocardiography (echo) has proven useful in the diagnosis, particularly in differentiating AL from constrictive pericarditis. The findings of thickened RV and LV myocardium, normal LV cavity dimension, and a diffuse hyperrefractile ''granular sparkling'' appearance are virtually diagnostic. Magnetic resonance (MR) imaging may improve the resolution of anatomic changes seen in cardiac AL and has the potential to provide more specific information based on biochemical tissue alterations. In this preliminary study, the authors obtained both MR and echo images in six patients with AL and biopsy-proven myocardial involvement. 5/6 patients also had Tc-99 PYP myocardial studies including emission tomography (SPECT). MR studies utilized a 0.6 Tesla superconductive magnet. End diastolic gated images were obtained with TE=30msec and TR=R-R interval on the ECG. 6/6 pts. showed LV wall thickening which was concentric and included the septum. Papillary muscles were identified in all and were enlarged in 3/6. 4/6 pts. showed RV wall thickening but to a lesser degree than LV. Pericardial effusions were present in 4 cases. These findings correlated well with the results of echo although MR gave better RV free wall resolution. PYP scans were positive in 3 pts. but there was no correlation with degree of LV thickening. The authors conclude that there are no identifiable MR findings in patients with cardiac AL which encourage further attempts to characterize myocardial involvement by measurement of MR relaxation times in vivo.

  17. Magnetic resonance spectroscopy in congenital heart disease.

    PubMed Central

    Miall-Allen, V. M.; Kemp, G. J.; Rajagopalan, B.; Taylor, D. J.; Radda, G. K.; Haworth, S. G.

    1996-01-01

    OBJECTIVE: To determine the feasibility of studying myocardial and skeletal muscle bioenergetics using 31P magnetic resonance spectroscopy (MRS) in babies and young children with congenital heart disease. SUBJECTS: 16 control subjects aged 5 months to 24 years and 18 patients with CHD, aged 7 months to 23 years, of whom 11 had cyanotic CHD, five had cardiac failure, and two had had a Senning procedure. DESIGN: 31P MRS was carried out using a 1.9 Tesla horizontal 65 cm bore whole body magnet to study the myocardium in 10 patients and skeletal muscle (gastrocnemius) in 14 patients, eight of whom were exercised, together with appropriate controls. RESULTS: In hypoxaemic patients, in skeletal muscle at rest intracellular pH (pHi) was abnormally high [7.06 (SEM 0.04) v 7.04 (0.05), P < 0.01] and showed a positive correlation with haemoglobin (P < 0.03). On exercise, hypoxaemic patients fatigued more quickly but end-exercise pHi and phosphocreatine recovery were normal, implying that an equivalent but smaller amount of work had been performed. End-exercise ADP concentration was lower. On recovery, the initial rate of phosphocreatine resynthesis was low. Skeletal muscle bioenergetics were within normal limits in those in heart failure. In the myocardium, the phosphocreatine/ATP ratio was similar in controls and hypoxaemic subjects, but low in those in heart failure. CONCLUSIONS: In heart failure, the myocardial phosphocreatine/ATP ratio was reduced, as in adults, while resting skeletal muscle studies were normal. By contrast, hypoxaemic children had normal myocardial bioenergetics, but showed skeletal muscle alkalinity, and energy reserves were more readily depleted on exercise. On recovery, the initially slow phosphocreatine resynthesis rate reflects a low rate of mitochondrial ATP synthesis, probably due to an inadequate oxygen supply. 31P MRS offers a safe, non-invasive method of studying myocardial and skeletal muscle bioenergetics in children as young as 5 months

  18. Real-time magnetic resonance imaging investigation of resonance tuning in soprano singing.

    PubMed

    Bresch, Erik; Narayanan, Shrikanth

    2010-11-01

    This article investigates using real-time magnetic resonance imaging the vocal tract shaping of 5 soprano singers during the production of two-octave scales of sung vowels. A systematic shift of the first vocal tract resonance frequency with respect to the fundamental is shown to exist for high vowels across all subjects. No consistent systematic effect on the vocal tract resonance could be shown across all of the subjects for other vowels or for the second vocal tract resonance. PMID:21110548

  19. Size Dependence of Ferromagnetic Resonance Frequency in Submicron Patterned Magnet

    NASA Astrophysics Data System (ADS)

    Manago, Takashi; Yamanoi, Kazuto; Yakata, Satoshi; Kimura, Takashi

    2013-05-01

    We investigated the size effect on ferromagnetic resonance (FMR) in a submicron-wide single permalloy bar. The resonant frequency markedly increased with decreasing bar width to less than 1 µm, since the demagnetizing field is effectively modified by changing the bar width even in thin films. The resonant frequency difference between 100- and 1000-nm-wide bars was over 4 GHz in the absence of a magnetic field. This characteristic is promising for practical microwave devices because the desired resonant frequency can be obtained simply by varying the width of narrow ferromagnetic bars so that it is not necessary to change the material or magnetic field.

  20. Nuclear magnetic resonance spectrometric assay of beta-lactamase.

    PubMed Central

    Kono, M; O'Hara, K; Shiomi, Y

    1980-01-01

    Beta-Lactam antibiotics and the crude enzyme were mixed in deuterium oxide and placed in a nuclear magnetic resonance tube. The change of the nuclear magnetic resonance spectrum during the enzymatic reaction was then analyzed to determine beta-lactamase activity. By using beta-lactam antibiotics such as penicillins, cephalosporins, and cephamycins as substrates, a comparison of the beta-lactamase activities was made between the nuclear magnetic resonance spectrometric assay and the iodometric assay. There was a close correlation between these two methods. PMID:6986114

  1. Advances in cardiac magnetic resonance imaging of congenital heart disease.

    PubMed

    Driessen, Mieke M P; Breur, Johannes M P J; Budde, Ricardo P J; van Oorschot, Joep W M; van Kimmenade, Roland R J; Sieswerda, Gertjan Tj; Meijboom, Folkert J; Leiner, Tim

    2015-01-01

    Due to advances in cardiac surgery, survival of patients with congenital heart disease has increased considerably during the past decades. Many of these patients require repeated cardiovascular magnetic resonance imaging to assess cardiac anatomy and function. In the past decade, technological advances have enabled faster and more robust cardiovascular magnetic resonance with improved image quality and spatial as well as temporal resolution. This review aims to provide an overview of advances in cardiovascular magnetic resonance hardware and acquisition techniques relevant to both pediatric and adult patients with congenital heart disease and discusses the techniques used to assess function, anatomy, flow and tissue characterization. PMID:25552386

  2. Fetal magnetic resonance imaging and ultrasound.

    PubMed

    Wataganara, Tuangsit; Ebrashy, Alaa; Aliyu, Labaran Dayyabu; Moreira de Sa, Renato Augusto; Pooh, Ritsuko; Kurjak, Asim; Sen, Cihat; Adra, Abdallah; Stanojevic, Milan

    2016-07-01

    Magnetic resonance imaging (MRI) has been increasingly adopted in obstetrics practice in the past three decades. MRI aids prenatal ultrasound and improves diagnostic accuracy for selected maternal and fetal conditions. However, it should be considered only when high-quality ultrasound cannot provide certain information that affects the counseling, prenatal intervention, pregnancy course, and delivery plan. Major indications of fetal MRI include, but are not restricted to, morbidly adherent placenta, selected cases of fetal brain anomalies, thoracic lesions (especially in severe congenital diaphragmatic hernia), and soft tissue tumors at head and neck regions of the fetus. For fetal anatomy assessment, a 1.5-Tesla machine with a fast T2-weighted single-shot technique is recommended for image requisition of common fetal abnormalities. Individual judgment needs to be applied when considering usage of a 3-Tesla machine. Gadolinium MRI contrast is not recommended during pregnancy. MRI should be avoided in the first half of pregnancy due to small fetal structures and motion artifacts. Assessment of fetal cerebral cortex can be achieved with MRI in the third trimester. MRI is a viable research tool for noninvasive interrogation of the fetus and the placenta. PMID:27092644

  3. Magnetic resonance imaging structured reporting in infertility.

    PubMed

    Montoliu-Fornas, Guillermina; Martí-Bonmatí, Luis

    2016-06-01

    Our objective was to define and propose a standardized magnetic resonance (MR) imaging structured report in patients with infertility to have clinical completeness on possible diagnosis and severity. Patients should be studied preferable on 3T equipment with a surface coil. Standard MR protocol should include high-resolution fast spin-echo T2-weighted, diffusion-weighted images and gradient-echo T1-weighted fat suppression images. The report should include ovaries (polycystic, endometrioma, tumor), oviduct (hydrosalpinx, hematosalpinx, pyosalpinx, peritubal anomalies), uterus (agenesia, hypoplasia, unicornuate, uterus didelphys, bicornuate, septate uterus), myometrium (leiomyomas, adenomyosis), endometrium (polyps, synechia, atrophy, neoplasia), cervix and vagina (isthmoceles, mucosal-parietal irregularity, stenosis, neoplasia), peritoneum (deep endometriosis), and urinary system-associated abnormalities. To be clinically useful, radiology reports must be structured, use standardized terminology, and convey actionable information. The structured report must comprise complete, comprehensive, and accurate information, allowing radiologists to continuously interact with patients and referring physicians to confirm that the information is used properly to affect the decision making process. PMID:27105717

  4. Vibration safety limits for magnetic resonance elastography

    NASA Astrophysics Data System (ADS)

    Ehman, E. C.; Rossman, P. J.; Kruse, S. A.; Sahakian, A. V.; Glaser, K. J.

    2008-02-01

    Magnetic resonance elastography (MRE) has been demonstrated to have potential as a clinical tool for assessing the stiffness of tissue in vivo. An essential step in MRE is the generation of acoustic mechanical waves within a tissue via a coupled mechanical driver. Motivated by an increasing volume of human imaging trials using MRE, the objectives of this study were to audit the vibration amplitude of exposure for our IRB-approved human MRE studies, to compare these values to a conservative regulatory standard for vibrational exposure and to evaluate the applicability and implications of this standard for MRE. MRE displacement data were examined from 29 MRE exams, including the liver, brain, kidney, breast and skeletal muscle. Vibrational acceleration limits from a European Union directive limiting occupational exposure to whole-body and extremity vibrations (EU 2002/44/EC) were adjusted for time and frequency of exposure, converted to maximum displacement values and compared to the measured in vivo displacements. The results indicate that the vibrational amplitudes used in MRE studies are below the EU whole-body vibration limit, and the EU guidelines represent a useful standard that could be readily accepted by Institutional Review Boards to define standards for vibrational exposures for MRE studies in humans.

  5. Segmentation of neuroanatomy in magnetic resonance images

    NASA Astrophysics Data System (ADS)

    Simmons, Andrew; Arridge, Simon R.; Barker, G. J.; Tofts, Paul S.

    1992-06-01

    Segmentation in neurological magnetic resonance imaging (MRI) is necessary for feature extraction, volume measurement and for the three-dimensional display of neuroanatomy. Automated and semi-automated methods offer considerable advantages over manual methods because of their lack of subjectivity, their data reduction capabilities, and the time savings they give. We have used dual echo multi-slice spin-echo data sets which take advantage of the intrinsically multispectral nature of MRI. As a pre-processing step, a rf non-uniformity correction is applied and if the data is noisy the images are smoothed using a non-isotropic blurring method. Edge-based processing is used to identify the skin (the major outer contour) and the eyes. Edge-focusing has been used to significantly simplify edge images and thus allow simple postprocessing to pick out the brain contour in each slice of the data set. Edge- focusing is a technique which locates significant edges using a high degree of smoothing at a coarse level and tracks these edges to a fine level where the edges can be determined with high positional accuracy. Both 2-D and 3-D edge-detection methods have been compared. Once isolated, the brain is further processed to identify CSF, and, depending upon the MR pulse sequence used, the brain itself may be sub-divided into gray matter and white matter using semi-automatic contrast enhancement and clustering methods.

  6. Progesterone-Targeted Magnetic Resonance Imaging Probes

    PubMed Central

    2015-01-01

    Determination of progesterone receptor (PR) status in hormone-dependent diseases is essential in ascertaining disease prognosis and monitoring treatment response. The development of a noninvasive means of monitoring these processes would have significant impact on early detection, cost, repeated measurements, and personalized treatment options. Magnetic resonance imaging (MRI) is widely recognized as a technique that can produce longitudinal studies, and PR-targeted MR probes may address a clinical problem by providing contrast enhancement that reports on PR status without biopsy. Commercially available MR contrast agents are typically delivered via intravenous injection, whereas steroids are administered subcutaneously. Whether the route of delivery is important for tissue accumulation of steroid-modified MRI contrast agents to PR-rich tissues is not known. To address this question, modification of the chemistry linking progesterone with the gadolinium chelate led to MR probes with increased water solubility and lower cellular toxicity and enabled administration through the blood. This attribute came at a cost through lower affinity for PR and decreased ability to cross the cell membrane, and ultimately it did not improve delivery of the PR-targeted MR probe to PR-rich tissues or tumors in vivo. Overall, these studies are important, as they demonstrate that targeted contrast agents require optimization of delivery and receptor binding of the steroid and the gadolinium chelate for optimal translation in vivo. PMID:25019183

  7. Magnetic resonance imaging of the kidneys

    SciTech Connect

    Leung, A.W.L.; Bydder, G.M.; Steinter, R.E.; Bryant, D.J.; Young, I.R.

    1984-12-01

    A study of the magnetic resonance imaging (MRI) appearance of the kidneys in six normal volunteers and 52 patients is reported. Corticomedullary differentiation was seen with the inversion-recovery (IR 1400/400) sequence in the normal volunteers and in patients with functioning transplanted kidneys and acute tubular necrosis. Partial or total loss of corticomedullary differentiation was seen in glomerulonephritis, acute and chronic renal failure, renal artery stenosis, and transplant rejection. The T1 of the kidneys was increased in glomerulonephritis with neuphrotic syndrome, but the T1 was within the normal range for renal medulla in glomerulonephritis without nephrotic syndrome, renal artery stenosis, and chronic renal failure. A large staghorn calculus was demonstrated with MRI, but small calculi were not seen. Fluid within the hydonephrosis, simple renal cysts, and polycystic kidneys displayed very low signal intensity and long T1 values. Tumors displayed varied appearances. Hypernephromas were shown to be hypo- or hyperintense with the renal medulla on the IR 1400/400 sequence. After intravenous injection of gadolinium-DTPA, there was marked decrease in the tumor T1.

  8. TOPICAL REVIEW: Endovascular interventional magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Bartels, L. W.; Bakker, C. J. G.

    2003-07-01

    Minimally invasive interventional radiological procedures, such as balloon angioplasty, stent placement or coiling of aneurysms, play an increasingly important role in the treatment of patients suffering from vascular disease. The non-destructive nature of magnetic resonance imaging (MRI), its ability to combine the acquisition of high quality anatomical images and functional information, such as blood flow velocities, perfusion and diffusion, together with its inherent three dimensionality and tomographic imaging capacities, have been advocated as advantages of using the MRI technique for guidance of endovascular radiological interventions. Within this light, endovascular interventional MRI has emerged as an interesting and promising new branch of interventional radiology. In this review article, the authors will give an overview of the most important issues related to this field. In this context, we will focus on the prerequisites for endovascular interventional MRI to come to maturity. In particular, the various approaches for device tracking that were proposed will be discussed and categorized. Furthermore, dedicated MRI systems, safety and compatibility issues and promising applications that could become clinical practice in the future will be discussed.

  9. Nuclear magnetic resonance imaging of the kidney

    SciTech Connect

    Hricak, H.; Crooks, L.; Sheldon, P.; Kaufman, L.

    1983-02-01

    The role of nuclear magnetic resonance (NMR) imaging of the kidney was analyzed in 18 persons (6 normal volunteers, 3 patients with pelvocaliectasis, 2 with peripelvic cysts, 1 with renal sinus lipomatosis, 3 with renal failure, 1 with glycogen storage disease, and 2 with polycystic kidney disease). Ultrasound and/or computed tomography (CT) studies were available for comparison in every case. In the normal kidney distinct anatomical structures were clearly differentiated by NMR. The best anatomical detail ws obtained with spin echo (SE) imaging, using a pulse sequence interval of 1,000 msec and an echo delay time of 28 msec. However, in the evaluation of normal and pathological conditions, all four intensity images (SE 500/28, SE 500/56, SE 1,000/28, and SE 1,000/56) have to be analyzed. No definite advantage was found in using SE imaging with a pulse sequence interval of 1,500 msec. Inversion recovery imaging enhanced the differences between the cortex and medulla, but it had a low signal-to-noise level and, therefore, a suboptimal overall resolution. The advantages of NMR compared with CT and ultrasound are discussed, and it is concluded that NMR imaging will prove to be a useful modality in the evaluation of renal disease.

  10. Stereotactic localization using magnetic resonance imaging.

    PubMed

    Walton, L; Hampshire, A; Forster, D M; Kemeny, A A

    1995-01-01

    A phantom study has been carried out to assess the accuracy of stereotactic localisation, using magnetic resonance imaging. The stereotactic coordinates of an array of Perspex rods within the phantom were determined and compared with measured values, in a series of transverse, coronal and sagittal images. In the transverse plane, the maximum errors experienced were X = 2.3 mm and Y = 10.7 mm. If the third fiducial plate, at the front of the frame, were not used in the scaling of the images, there was considerable improvement in the Y direction (maximum error Y = 2.1 mm). However, some deterioration in the accuracy in the X direction resulted, particularly at the extremes of Z (maximum error X = 3.5 mm). In the coronal plane, the maximum errors were X = 1.8 mm and Z = 8.0 mm. With the third plate off, the errors decreased to X = 1.9 mm and Z = 3.3 mm. In the sagittal plane, the maximum errors recorded were Y = 1.1 mm and Z = 7.5 mm. It is not possible to calibrate in this plane without the third plate. PMID:8584823

  11. Compression-sensitive magnetic resonance elastography

    NASA Astrophysics Data System (ADS)

    Hirsch, Sebastian; Beyer, Frauke; Guo, Jing; Papazoglou, Sebastian; Tzschaetzsch, Heiko; Braun, Juergen; Sack, Ingolf

    2013-08-01

    Magnetic resonance elastography (MRE) quantifies the shear modulus of biological tissue to detect disease. Complementary to the shear elastic properties of tissue, the compression modulus may be a clinically useful biomarker because it is sensitive to tissue pressure and poromechanical interactions. In this work, we analyze the capability of MRE to measure volumetric strain and the dynamic bulk modulus (P-wave modulus) at a harmonic drive frequency commonly used in shear-wave-based MRE. Gel phantoms with various densities were created by introducing CO2-filled cavities to establish a compressible effective medium. The dependence of the effective medium's bulk modulus on phantom density was investigated via static compression tests, which confirmed theoretical predictions. The P-wave modulus of three compressible phantoms was calculated from volumetric strain measured by 3D wave-field MRE at 50 Hz drive frequency. The results demonstrate the MRE-derived volumetric strain and P-wave modulus to be sensitive to the compression properties of effective media. Since the reconstruction of the P-wave modulus requires third-order derivatives, noise remains critical, and P-wave moduli are systematically underestimated. Focusing on relative changes in the effective bulk modulus of tissue, compression-sensitive MRE may be useful for the noninvasive detection of diseases involving pathological pressure alterations such as hepatic hypertension or hydrocephalus.

  12. Magnetic resonance--guided musculoskeletal interventional radiology.

    PubMed

    Carrino, John A; Blanco, Roberto

    2006-06-01

    As an imaging modality, magnetic resonance (MR) guidance has great potential to direct diagnostic and therapeutic procedures performed in the musculoskeletal region and influence patient management. MR-guided interventional procedures involving bone, soft tissue, intervertebral discs, and joints are safe and sufficiently effective for use in clinical practice. This article discusses and illustrates the procedural characteristics and techniques when performing MR-guided musculoskeletal interventions. Biopsy procedures are similar to other modalities for bone and soft tissue lesions. MR guidance is advantageous if the lesion is not visible by other modalities and for regions adjacent to hardware and implants, subselective targeting, intra-articular locations, and periarticular cyst aspiration. MR guidance has also been used for a host of spine injections and pain management procedures such as sacroiliac joint injections, discography, transforaminal epidural injection, selective nerve block, sympathetic block, celiac plexus block, and facet joint cryotherapy neurotomies. Future directions of clinical applications include tumor ablation and multimodality procedure suites. MR-guided musculoskeletal procedures will continue to be a growth area particularly for the diagnosis and treatment of bone and soft tissue neoplasia. PMID:16586322

  13. Magnetic resonance imaging: present and future applications

    PubMed Central

    Johnston, Donald L.; Liu, Peter; Wismer, Gary L.; Rosen, Bruce R.; Stark, David D.; New, Paul F.J.; Okada, Robert D.; Brady, Thomas J.

    1985-01-01

    Magnetic resonance (MR) imaging has created considerable excitement in the medical community, largely because of its great potential to diagnose and characterize many different disease processes. However, it is becoming increasingly evident that, because MR imaging is similar to computed tomography (CT) scanning in identifying structural disorders and because it is more costly and difficult to use, this highly useful technique must be judged against CT before it can become an accepted investigative tool. At present MR imaging has demonstrated diagnostic superiority over CT in a limited number of important, mostly neurologic, disorders and is complementary to CT in the diagnosis of certain other disorders. For most of the remaining organ systems its usefulness is not clear, but the lack of ionizing radiation and MR's ability to produce images in any tomographic plane may eventually prove to be advantageous. The potential of MR imaging to display in-vivo spectra, multinuclear images and blood-flow data makes it an exciting investigative technique. At present, however, MR imaging units should be installed only in medical centres equipped with the clinical and basic research facilities that are essential to evaluate the ultimate role of this technique in the care of patients. ImagesFig. 5Fig. 6Fig. 7Fig. 8Fig. 9Fig. 10Fig. 11Fig. 12Fig. 13Fig. 14 PMID:3884120

  14. [Magnetic resonance angiography of the renal arteries].

    PubMed

    Matos, C; Metens, T; Nicaise, N; Golzarian, J; Dussaussois, L; Struyven, J

    1999-09-01

    Initially, the clinical use of magnetic resonance angiography (MRA) in the abdomen has been restricted because of motion and flow related artifacts. The advent of high performance gradient systems made possible the development of 3D gadolinium-enhanced MRA techniques and expanded the clinical applications of MRA into the abdominal area, particularly for the investigation of renal arteries. This technique is safe, because the administered contrast agent (gadolinium) is free of clinically detectable nephrotoxicity and has a low incidence of allergic reactions. Moreover, contrast MRA also eliminates the risks of ionizing radiation which allows repeating the examination without the accumulation of radiation exposure. The main disadvantages of the technique are its low availability and the fact that the use of contrast agents for this procedure is still not reimbursed by the social security. Many studies demonstrated that contrast MRA allows for the reliable assessment of renal artery morphology and pathologic states. Furthermore, within a single MR examination a comprehensive approach including renal artery morphology, hemodynamic significance of any stenosis and kidney perfusion is available. In this paper, we provide a review of the literature concerning the clinical performance of contrast MRA for the renal arteries and suggest its rationale for the investigation of patients suspected of renovascular disease in our specific environment. PMID:10523920

  15. Compression-sensitive magnetic resonance elastography.

    PubMed

    Hirsch, Sebastian; Beyer, Frauke; Guo, Jing; Papazoglou, Sebastian; Tzschaetzsch, Heiko; Braun, Juergen; Sack, Ingolf

    2013-08-01

    Magnetic resonance elastography (MRE) quantifies the shear modulus of biological tissue to detect disease. Complementary to the shear elastic properties of tissue, the compression modulus may be a clinically useful biomarker because it is sensitive to tissue pressure and poromechanical interactions. In this work, we analyze the capability of MRE to measure volumetric strain and the dynamic bulk modulus (P-wave modulus) at a harmonic drive frequency commonly used in shear-wave-based MRE. Gel phantoms with various densities were created by introducing CO2-filled cavities to establish a compressible effective medium. The dependence of the effective medium's bulk modulus on phantom density was investigated via static compression tests, which confirmed theoretical predictions. The P-wave modulus of three compressible phantoms was calculated from volumetric strain measured by 3D wave-field MRE at 50 Hz drive frequency. The results demonstrate the MRE-derived volumetric strain and P-wave modulus to be sensitive to the compression properties of effective media. Since the reconstruction of the P-wave modulus requires third-order derivatives, noise remains critical, and P-wave moduli are systematically underestimated. Focusing on relative changes in the effective bulk modulus of tissue, compression-sensitive MRE may be useful for the noninvasive detection of diseases involving pathological pressure alterations such as hepatic hypertension or hydrocephalus. PMID:23852144

  16. Scatter-based magnetic resonance elastography

    NASA Astrophysics Data System (ADS)

    Papazoglou, Sebastian; Xu, Chao; Hamhaber, Uwe; Siebert, Eberhard; Bohner, Georg; Klingebiel, Randolf; Braun, Jürgen; Sack, Ingolf

    2009-04-01

    Elasticity is a sensitive measure of the microstructural constitution of soft biological tissues and increasingly used in diagnostic imaging. Magnetic resonance elastography (MRE) uniquely allows in vivo measurement of the shear elasticity of brain tissue. However, the spatial resolution of MRE is inherently limited as the transformation of shear wave patterns into elasticity maps requires the solution of inverse problems. Therefore, an MRE method is introduced that avoids inversion and instead exploits shear wave scattering at elastic interfaces between anatomical regions of different shear compliance. This compliance-weighted imaging (CWI) method can be used to evaluate the mechanical consistency of cerebral lesions or to measure relative stiffness differences between anatomical subregions of the brain. It is demonstrated that CWI-MRE is sensitive enough to reveal significant elasticity variations within inner brain parenchyma: the caudate nucleus (head) was stiffer than the lentiform nucleus and the thalamus by factors of 1.3 ± 0.1 and 1.7 ± 0.2, respectively (P < 0.001). CWI-MRE provides a unique method for characterizing brain tissue by identifying local stiffness variations.

  17. Magnetic Resonance Angiography of the Aorta

    PubMed Central

    Takehara, Yasuo; Yamashita, Shuhei; Sakahara, Harumi; Masui, Takayuki; Isoda, Haruo

    2011-01-01

    Magnetic resonance angiography (MRA) is capable of imaging arteries in the half to whole body by a single acquisition without a nephrotoxic contrast medium, and acquired images can be reconstructed into a specific cross-sectional view in an arbitrary directions. MRA is applicable for vessels non-reachable by a catheter approach, and collateral vessels can be fully visualized. Since MRA is minimally-invasive with no exposure to ionized radiation, it can be repeatedly applied for follow-up. However, there are also disadvantages: the temporal and spatial resolutions are inferior to those of X-ray angiography, and, at present, it cannot be used as a guide for intervention. Moreover, gadolinium administrations may cause NSF in patients who have lost renal function, as a new risk. Accordingly, strict consideration is required for an indication of its application. Development of non-contrast MRA and evaluation of the wall itself may draw more attention in the future. Plaque imaging is being routinely performed nowadays, and the measurement of vascular wall shear stress, which has a close association with arteriosclerosis, may become possible by utilizing the time-resolved phase-contrast method capable of measuring the time-resolved velocity vectors of blood flow throughout the body. (*English Translation of J Jpn Coll Angiol, 2009, 49: 503-516.) PMID:23555465

  18. Magnetic Resonance Elastography: Inversions in Bounded Media

    PubMed Central

    Kolipaka, Arunark; McGee, Kiaran P.; Manduca, Armando; Romano, Anthony J.; Glaser, Kevin J.; Araoz, Philip A.; Ehman, Richard L.

    2009-01-01

    Magnetic resonance elastography (MRE) is a noninvasive imaging technique capable of quantifying and spatially resolving the shear stiffness of soft tissues by visualization of synchronized mechanical wave displacement fields. However, MRE inversions generally assume that the measured tissue motion consists primarily of shear waves propagating in a uniform, infinite medium. This assumption is not valid in organs such as the heart, eye, bladder, skin, fascia, bone and spinal cord in which the shear wavelength approaches the geometric dimensions of the object. The aim of this study was to develop and test mathematical inversion algorithms capable of resolving shear stiffness from displacement maps of flexural waves propagating in bounded media such as beams, plates and spherical shells using geometry-specific equations of motion. MRE and finite element modeling (FEM) of beam, plate, and spherical shell phantoms of various geometries were performed. Mechanical testing of the phantoms agreed with the stiffness values obtained from FEM and MRE data and a linear correlation of r2 ≥ 0.99 was observed between the stiffness values obtained using MRE and FEM data. In conclusion, we have demonstrated new inversion methods for calculating shear stiffness that may be more appropriate for waves propagating in bounded media. PMID:19780146

  19. Magnetic Resonance Imaging at Ultrahigh Fields

    PubMed Central

    Uğurbil, Kamil

    2014-01-01

    Since the introduction of 4 T human systems in three academic laboratories circa 1990, rapid progress in imaging and spectroscopy studies in humans at 4 T and animal model systems at 9.4 T have led to the introduction of 7 T and higher magnetic fields for human investigation at about the turn of the century. Work conducted on these platforms has demonstrated the existence of significant advantages in SNR and biological information content at these ultrahigh fields, as well as the presence of numerous challenges. Primary difference from lower fields is the deviation from the near field regime; at the frequencies corresponding to hydrogen resonance conditions at ultrahigh fields, the RF is characterized by attenuated traveling waves in the human body, which leads to image nonuniformities for a given sample-coil configuration because of interferences. These nonuniformities were considered detrimental to the progress of imaging at high field strengths. However, they are advantageous for parallel imaging for signal reception and parallel transmission, two critical technologies that account, to a large extend, for the success of ultrahigh fields. With these technologies, and improvements in instrumentation and imaging methods, ultra-high fields have provided unprecedented gains in imaging of brain function and anatomy, and started to make inroads into investigation of the human torso and extremities. As extensive as they are, these gains still constitute a prelude to what is to come given the increasingly larger effort committed to ultrahigh field research and development of ever better instrumentation and techniques. PMID:24686229

  20. Magnetic resonance imaging in brachial plexus injury.

    PubMed

    Caranci, F; Briganti, F; La Porta, M; Antinolfi, G; Cesarano, E; Fonio, P; Brunese, L; Coppolino, F

    2013-08-01

    Brachial plexus injury represents the most severe nerve injury of the extremities. While obstetric brachial plexus injury has showed a reduction in the number of cases due to the improvements in obstetric care, brachial plexus injury in the adult is an increasingly common clinical problem. The therapeutic measures depend on the pathologic condition and the location of the injury: Preganglionic avulsions are usually not amenable to surgical repair; function of some denervated muscles can be restored with nerve transfers from intercostals or accessory nerves and contralateral C7 transfer. Postganglionic avulsions are repaired with excision of the damaged segment and nerve autograft between nerve ends or followed up conservatively. Magnetic resonance imaging is the modality of choice for depicting the anatomy and pathology of the brachial plexus: It demonstrates the location of the nerve damage (crucial for optimal treatment planning), depicts the nerve continuity (with or without neuroma formation), or may show a completely disrupted/avulsed nerve, thereby aiding in nerve-injury grading for preoperative planning. Computed tomography myelography has the advantage of a higher spatial resolution in demonstration of nerve roots compared with MR myelography; however, it is invasive and shows some difficulties in the depiction of some pseudomeningoceles with little or no communication with the dural sac. PMID:23949940

  1. Magnetic Resonance Imaging of Pituitary Tumors.

    PubMed

    Bonneville, Jean-François

    2016-01-01

    Magnetic Resonance Imaging (MRI) is currently considered a major keystone of the diagnosis of diseases of the hypothalamic-hypophyseal region. However, the relatively small size of the pituitary gland, its location deep at the skull base and the numerous physiological variants present in this area impede the precise assessment of the anatomical structures and, particularly, of the pituitary gland itself. The diagnosis of the often tiny lesions of this region--such as pituitary microadenomas--is then difficult if the MRI technology is not optimized and if potential artifacts and traps are not recognized. Advanced MRI technology can not only depict small lesions with greater reliability, but also help in the differential diagnosis of large tumors. In these, defining the presence or absence of invasion is a particularly important task. This review describes and illustrates the radiological diagnosis of the different tumors of the sellar region, from the common prolactinomas, nonfunctioning adenomas and Rathke's cleft cysts, to the less frequent and more difficult to detect corticotroph pituitary adenomas in Cushing's disease, and other neoplastic and nonneoplastic entities. Finally, some hints are given to facilitate the differential diagnosis of sellar lesions. PMID:27003878

  2. Magnetic Resonance Imaging of Cartilage Repair

    PubMed Central

    Trattnig, Siegfried; Winalski, Carl S.; Marlovits, Stephan; Jurvelin, Jukka S.; Welsch, Goetz H.; Potter, Hollis G.

    2011-01-01

    Articular cartilage lesions are a common pathology of the knee joint, and many patients may benefit from cartilage repair surgeries that offer the chance to avoid the development of osteoarthritis or delay its progression. Cartilage repair surgery, no matter the technique, requires a noninvasive, standardized, and high-quality longitudinal method to assess the structure of the repair tissue. This goal is best fulfilled by magnetic resonance imaging (MRI). The present article provides an overview of the current state of the art of MRI of cartilage repair. In the first 2 sections, preclinical and clinical MRI of cartilage repair tissue are described with a focus on morphological depiction of cartilage and the use of functional (biochemical) MR methodologies for the visualization of the ultrastructure of cartilage repair. In the third section, a short overview is provided on the regulatory issues of the United States Food and Drug Administration (FDA) and the European Medicines Agency (EMEA) regarding MR follow-up studies of patients after cartilage repair surgeries. PMID:26069565

  3. Magnetic resonance imaging of benign prostatic hyperplasia

    PubMed Central

    Guneyli, Serkan; Ward, Emily; Thomas, Stephen; Yousuf, Ambereen Nehal; Trilisky, Igor; Peng, Yahui; Antic, Tatjana; Oto, Aytekin

    2016-01-01

    Benign prostatic hyperplasia (BPH) is a common condition in middle-aged and older men and negatively affects the quality of life. An ultrasound classification for BPH based on a previous pathologic classification was reported, and the types of BPH were classified according to different enlargement locations in the prostate. Afterwards, this classification was demonstrated using magnetic resonance imaging (MRI). The classification of BPH is important, as patients with different types of BPH can have different symptoms and treatment options. BPH types on MRI are as follows: type 0, an equal to or less than 25 cm3 prostate showing little or no zonal enlargements; type 1, bilateral transition zone (TZ) enlargement; type 2, retrourethral enlargement; type 3, bilateral TZ and retrourethral enlargement; type 4, pedunculated enlargement; type 5, pedunculated with bilateral TZ and/or retrourethral enlargement; type 6, subtrigonal or ectopic enlargement; type 7, other combinations of enlargements. We retrospectively evaluated MRI images of BPH patients who were histologically diagnosed and presented the different types of BPH on MRI. MRI, with its advantage of multiplanar imaging and superior soft tissue contrast resolution, can be used in BPH patients for differentiation of BPH from prostate cancer, estimation of zonal and entire prostatic volumes, determination of the stromal/glandular ratio, detection of the enlargement locations, and classification of BPH types which may be potentially helpful in choosing the optimal treatment. PMID:27015442

  4. Resonant microwave cavity for 8.5-12 GHz optically detected electron spin resonance with simultaneous nuclear magnetic resonance

    NASA Astrophysics Data System (ADS)

    Colton, J. S.; Wienkes, L. R.

    2009-03-01

    We present a newly developed microwave resonant cavity for use in optically detected magnetic resonance (ODMR) experiments. The cylindrical quasi-TE011 mode cavity is designed to fit in a 1 in. magnet bore to allow the sample to be optically accessed and to have an adjustable resonant frequency between 8.5 and 12 GHz. The cavity uses cylinders of high dielectric material, so-called "dielectric resonators," in a double-stacked configuration to determine the resonant frequency. Wires in a pseudo-Helmholtz configuration are incorporated into the cavity to provide frequencies for simultaneous nuclear magnetic resonance (NMR). The system was tested by measuring cavity absorption as microwave frequencies were swept, by performing ODMR on a zinc-doped InP sample, and by performing optically detected NMR on a GaAs sample. The results confirm the suitability of the cavity for ODMR with simultaneous NMR.

  5. Magnetic resonance force microscopy with a permanent magnet on the cantilever

    SciTech Connect

    Zhang, Z.; Hammel, P.C.

    1997-02-01

    The magnetic resonance force microscope (MRFM) is a microscopic 3-D imaging instrument based on a recent proposal to detect magnetic resonance signals mechanically using a micro-mechanical resonator. MRFM has been successfully demonstrated in various magnetic resonance experiments including electron spin resonance, ferromagnetic resonances and nuclear magnetic resonance. In order to apply this ultra-high, 3-D spatial resolution technique to samples of arbitrary size and shape, the magnetic particle which generates the field gradient {del}{bold B}, (and, therefore, the force {bold F = (m {center_dot} {del}B)} between itself and the spin magnetization {bold m} of the sample) will need to be mounted on the mechanical resonator. Up to the present, all experiments have been performed with the sample mounted on the resonator. This is done, in part, to avoid the spurious response of the mechanical resonator which is generated by the variation of the magnetization of the magnetic particle as the external field is varied.

  6. Sensitive magnetic force detection with a carbon nanotube resonator

    SciTech Connect

    Willick, Kyle; Haapamaki, Chris; Baugh, Jonathan

    2014-03-21

    We propose a technique for sensitive magnetic point force detection using a suspended carbon nanotube (CNT) mechanical resonator combined with a magnetic field gradient generated by a ferromagnetic gate electrode. Numerical calculations of the mechanical resonance frequency show that single Bohr magneton changes in the magnetic state of an individual magnetic molecule grafted to the CNT can translate to detectable frequency shifts, on the order of a few kHz. The dependences of the resonator response to device parameters such as length, tension, CNT diameter, and gate voltage are explored and optimal operating conditions are identified. A signal-to-noise analysis shows that, in principle, magnetic switching at the level of a single Bohr magneton can be read out in a single shot on timescales as short as 10 μs. This force sensor should enable new studies of spin dynamics in isolated single molecule magnets, free from the crystalline or ensemble settings typically studied.

  7. Dynamic nuclear polarization in a magnetic resonance force microscope experiment.

    PubMed

    Issac, Corinne E; Gleave, Christine M; Nasr, Paméla T; Nguyen, Hoang L; Curley, Elizabeth A; Yoder, Jonilyn L; Moore, Eric W; Chen, Lei; Marohn, John A

    2016-04-01

    We report achieving enhanced nuclear magnetization in a magnetic resonance force microscope experiment at 0.6 tesla and 4.2 kelvin using the dynamic nuclear polarization (DNP) effect. In our experiments a microwire coplanar waveguide delivered radiowaves to excite nuclear spins and microwaves to excite electron spins in a 250 nm thick nitroxide-doped polystyrene sample. Both electron and proton spin resonance were observed as a change in the mechanical resonance frequency of a nearby cantilever having a micron-scale nickel tip. NMR signal, not observable from Curie-law magnetization at 0.6 T, became observable when microwave irradiation was applied to saturate the electron spins. The resulting NMR signal's size, buildup time, dependence on microwave power, and dependence on irradiation frequency was consistent with a transfer of magnetization from electron spins to nuclear spins. Due to the presence of an inhomogeneous magnetic field introduced by the cantilever's magnetic tip, the electron spins in the sample were saturated in a microwave-resonant slice 10's of nm thick. The spatial distribution of the nuclear polarization enhancement factor ε was mapped by varying the frequency of the applied radiowaves. The observed enhancement factor was zero for spins in the center of the resonant slice, was ε = +10 to +20 for spins proximal to the magnet, and was ε = -10 to -20 for spins distal to the magnet. We show that this bipolar nuclear magnetization profile is consistent with cross-effect DNP in a ∼10(5) T m(-1) magnetic field gradient. Potential challenges associated with generating and using DNP-enhanced nuclear magnetization in a nanometer-resolution magnetic resonance imaging experiment are elucidated and discussed. PMID:26964007

  8. Distribution of Hyperpolarized Xenon in the Brain Following Sensory Stimulation: Preliminary MRI Findings

    PubMed Central

    Mazzanti, Mary L.; Walvick, Ronn P.; Zhou, Xin; Sun, Yanping; Shah, Niral; Mansour, Joey; Gereige, Jessica; Albert, Mitchell S.

    2011-01-01

    In hyperpolarized xenon magnetic resonance imaging (HP 129Xe MRI), the inhaled spin-1/2 isotope of xenon gas is used to generate the MR signal. Because hyperpolarized xenon is an MR signal source with properties very different from those generated from water-protons, HP 129Xe MRI may yield structural and functional information not detectable by conventional proton-based MRI methods. Here we demonstrate the differential distribution of HP 129Xe in the cerebral cortex of the rat following a pain stimulus evoked in the animal's forepaw. Areas of higher HP 129Xe signal corresponded to those areas previously demonstrated by conventional functional MRI (fMRI) methods as being activated by a forepaw pain stimulus. The percent increase in HP 129Xe signal over baseline was 13–28%, and was detectable with a single set of pre and post stimulus images. Recent innovations in the production of highly polarized 129Xe should make feasible the emergence of HP 129Xe MRI as a viable adjunct method to conventional MRI for the study of brain function and disease. PMID:21789173

  9. Beam induced electron cloud resonances in dipole magnetic fields

    NASA Astrophysics Data System (ADS)

    Calvey, J. R.; Hartung, W.; Makita, J.; Venturini, M.

    2016-07-01

    The buildup of low energy electrons in an accelerator, known as electron cloud, can be severely detrimental to machine performance. Under certain beam conditions, the beam can become resonant with the cloud dynamics, accelerating the buildup of electrons. This paper will examine two such effects: multipacting resonances, in which the cloud development time is resonant with the bunch spacing, and cyclotron resonances, in which the cyclotron period of electrons in a magnetic field is a multiple of bunch spacing. Both resonances have been studied directly in dipole fields using retarding field analyzers installed in the Cornell Electron Storage Ring. These measurements are supported by both analytical models and computer simulations.

  10. Broadband electrically detected magnetic resonance using adiabatic pulses.

    PubMed

    Hrubesch, F M; Braunbeck, G; Voss, A; Stutzmann, M; Brandt, M S

    2015-05-01

    We present a broadband microwave setup for electrically detected magnetic resonance (EDMR) based on microwave antennae with the ability to apply arbitrarily shaped pulses for the excitation of electron spin resonance (ESR) and nuclear magnetic resonance (NMR) of spin ensembles. This setup uses non-resonant stripline structures for on-chip microwave delivery and is demonstrated to work in the frequency range from 4 MHz to 18 GHz. π pulse times of 50 ns and 70 μs for ESR and NMR transitions, respectively, are achieved with as little as 100 mW of microwave or radiofrequency power. The use of adiabatic pulses fully compensates for the microwave magnetic field inhomogeneity of the stripline antennae, as demonstrated with the help of BIR4 unitary rotation pulses driving the ESR transition of neutral phosphorus donors in silicon and the NMR transitions of ionized phosphorus donors as detected by electron nuclear double resonance (ENDOR). PMID:25828243

  11. Resonant Raman scattering from silicon nanoparticles enhanced by magnetic response.

    PubMed

    Dmitriev, Pavel A; Baranov, Denis G; Milichko, Valentin A; Makarov, Sergey V; Mukhin, Ivan S; Samusev, Anton K; Krasnok, Alexander E; Belov, Pavel A; Kivshar, Yuri S

    2016-05-01

    Enhancement of optical response with high-index dielectric nanoparticles is attributed to the excitation of their Mie-type magnetic and electric resonances. Here we study Raman scattering from crystalline silicon nanoparticles and reveal that magnetic dipole modes have a much stronger effect on the scattering than electric modes of the same order. We demonstrate experimentally a 140-fold enhancement of the Raman signal from individual silicon spherical nanoparticles at the magnetic dipole resonance. Our results confirm the importance of the optically-induced magnetic response of subwavelength dielectric nanoparticles for enhancing light-matter interactions. PMID:27113352

  12. Element Selective X-ray Detected Magnetic Resonance

    SciTech Connect

    Goulon, J.; Rogalev, A.; Wilhelm, F.; Jaouen, N.; Goulon-Ginet, C.; Goujon, G.; Youssef, J. Ben; Indenbom, M. V.

    2007-01-19

    Element selective X-ray Detected Magnetic Resonance (XDMR) was measured on exciting the Fe K-edge in a high quality YIG thin film. Resonant pumping at high microwave power was achieved in the nonlinear foldover regime and X-ray Magnetic Circular Dichroism (XMCD) was used to probe the time-invariant change of the magnetization {delta}Mz due to the precession of orbital magnetization densities of states (DOS) at the Fe sites. This challenging experiment required us to design a specific instrumentation which is briefly described.

  13. Magnetic Resonance in an Atomic Vapor Excited by a Mechanical Resonator

    NASA Astrophysics Data System (ADS)

    Wang, Ying-Ju; Eardley, Matthew; Knappe, Svenja; Moreland, John; Hollberg, Leo; Kitching, John

    2006-12-01

    We demonstrate a direct resonant interaction between the mechanical motion of a mesoscopic resonator and the spin degrees of freedom of a sample of neutral atoms in the gas phase. This coupling, mediated by a magnetic particle attached to the tip of the miniature mechanical resonator, excites a coherent precession of the atomic spins about a static magnetic field. The novel coupled atom-resonator system may enable development of low-power, high-performance sensors, and enhance research efforts connected with the manipulation of cold atoms, quantum control, and high-resolution microscopy.

  14. Magnetic Resonance Fiber Tracking in a Neonate with Hemimegalencephaly

    PubMed Central

    Re, Thomas J; Scarciolla, Laura; Takahashi, Emi; Specchio, Nicola; Bernardi, Bruno; Longo, Daniela

    2015-01-01

    A magnetic resonance diffusion fiber tracking study in neonate diagnosed with left hemisphere hemimegalencephaly is presented. Despite diffuse morphologic deformities identified in conventional imaging, all major pathways were identifiable bilaterally with minor aberrations in vicinity of morphologic lesions. PMID:25655045

  15. Nuclear magnetic resonance imaging in patients with cardiac pacing devices.

    PubMed

    Buendía, Francisco; Sánchez-Gómez, Juan M; Sancho-Tello, María J; Olagüe, José; Osca, Joaquín; Cano, Oscar; Arnau, Miguel A; Igual, Begoña

    2010-06-01

    Currently, nuclear magnetic resonance imaging is contraindicated in patients with a pacemaker or implantable cardioverter-defibrillator. This study was carried out because the potential risks in this situation need to be clearly defined. This prospective study evaluated clinical and electrical parameters before and after magnetic resonance imaging was performed in 33 patients (five with implantable cardioverter-defibrillators and 28 with pacemakers). In these patients, magnetic resonance imaging was considered clinically essential. There were no clinical complications. There was a temporary communication failure in two cases, sensing errors during imaging in two cases, and a safety signal was generated in one pacemaker at the maximum magnetic resonance frequency and output level. There were no technical restrictions on imaging nor were there any permanent changes in the performance of the cardiac pacing device. PMID:20515632

  16. Imaging agents for in vivo magnetic resonance and scintigraphic imaging

    DOEpatents

    Engelstad, B.L.; Raymond, K.N.; Huberty, J.P.; White, D.L.

    1991-04-23

    Methods are provided for in vivo magnetic resonance imaging and/or scintigraphic imaging of a subject using chelated transition metal and lanthanide metal complexes. Novel ligands for these complexes are provided. No Drawings

  17. Nuclear Magnetic Double Resonance Using Weak Perturbing RF Fields

    ERIC Educational Resources Information Center

    Reynolds, G. Fredric

    1977-01-01

    Describes a nuclear magnetic resonance experimental example of spin tickling; also discusses a direct approach for verifying the relative signs of coupling constants in three-spin cyclopropyl systems. (SL)

  18. Imaging agents for in vivo magnetic resonance and scintigraphic imaging

    DOEpatents

    Engelstad, Barry L.; Raymond, Kenneth N.; Huberty, John P.; White, David L.

    1991-01-01

    Methods are provided for in vivo magnetic resonance imaging and/or scintigraphic imaging of a subject using chelated transition metal and lanthanide metal complexes. Novel ligands for these complexes are provided.

  19. 76 FR 58281 - Magnetic Resonance Imaging Safety; Public Workshop

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-09-20

    ... the safe use of magnetic resonance imaging (MRI) and approaches to mitigate risks. The overall goal is... overview of the Connect Pro program, visit: http://www.adobe.com/go/connectpro_overview . (FDA has...

  20. Diagnosis of hematogenous pyogenic vertebral osteomyelitis by magnetic resonance imaging

    SciTech Connect

    Meyers, S.P.; Wiener, S.N. )

    1991-04-01

    The clinical information and imaging data from 27 patients with hematogenous pyogenic vertebral osteomyelitis were reviewed. All patients had roentgenographic and magnetic resonance imaging examinations. Seventeen patients had computed tomograms; 17 had technetium Tc 99m medronate bone scans; and seven had gallium citrate Ga 67 scans. Magnetic resonance imaging, when used as a part of the initial radiologic evaluation, detected abnormalities consistent with osteomyelitis in all 27 patients. Magnetic resonance imaging also demonstrated paravertebral and/or epidural extension of infection in 14 patients, including seven patients who had neurologic signs of lower-extremity weakness. Roentgenograms, computed tomograms, technetium bone scans, and gallium scans had findings suggestive of the diagnosis in 48%, 65%, 71%, and 86% of the patients, respectively. We recommend magnetic resonance imaging as an important and perhaps critical imaging modality for detection of pyogenic vertebral osteomyelitis.

  1. [Magnetic resonance tomography in injuries of the cervical spine].

    PubMed

    Meydam, K; Sehlen, S; Schlenkhoff, D; Kiricuta, J C; Beyer, H K

    1986-12-01

    Twenty patients who had suffered spinal trauma were examined by magnetic resonance tomography. Fifteen patients with first degree trauma in Erdmann's classification showed no abnormality. Magnetic resonance tomography of the cervical spine appears to be a suitable method for investigating patients with whiplash injuries. It is indicated following severe flexion injuries with subluxations and neurological symptoms, since it is the only method that can demonstrate the spinal cord directly and completely and show the extent of cord compression. For patients with thoracic trauma and rapidly developing neurological symptoms, magnetic resonance tomography is ideal for showing post-traumatic syringomyelia. Magnetic resonance tomography following whiplash injuries is recommended if plain films of the cervical spine show any abnormalities, as well as for the investigation of acute or sub-acute neurological abnormalities. The various findings are discussed. PMID:3025951

  2. Inhalant-Abuse Myocarditis Diagnosed by Cardiac Magnetic Resonance

    PubMed Central

    Rao, Krishnasree; Matulevicius, Susan

    2016-01-01

    Multiple reports of toxic myocarditis from inhalant abuse have been reported. We now report the case of a 23-year-old man found to have toxic myocarditis from inhalation of a hydrocarbon. The diagnosis was made by means of cardiac magnetic resonance imaging with delayed enhancement. The use of cardiac magnetic resonance to diagnose myocarditis has become increasingly common in clinical medicine, although there is not a universally accepted criterion for diagnosis. We appear to be the first to document a case of toxic myocarditis diagnosed by cardiac magnetic resonance. In patients with a history of drug abuse who present with clinical findings that suggest myocarditis or pericarditis, cardiac magnetic resonance can be considered to support the diagnosis. PMID:27303242

  3. Nonlinear magnetization dynamics of antiferromagnetic spin resonance induced by intense terahertz magnetic field

    NASA Astrophysics Data System (ADS)

    Mukai, Y.; Hirori, H.; Yamamoto, T.; Kageyama, H.; Tanaka, K.

    2016-01-01

    We report on the nonlinear magnetization dynamics of a HoFeO3 crystal induced by a strong terahertz magnetic field resonantly enhanced with a split ring resonator and measured with magneto-optical Kerr effect microscopy. The terahertz magnetic field induces a large change (˜40%) in the spontaneous magnetization. The frequency of the antiferromagnetic resonance decreases in proportion to the square of the magnetization change. A modified Landau-Lifshitz-Gilbert equation with a phenomenological nonlinear damping term quantitatively reproduced the nonlinear dynamics.

  4. Use of Magnetic Resonance in the Evaluation of Cranial Trauma.

    PubMed

    Altmeyer, Wilson; Steven, Andrew; Gutierrez, Juan

    2016-05-01

    MR imaging is an extremely useful tool in the evaluation of traumatic brain injury in the emergency department. Although CT still plays the dominant role in urgent patient triage, MR imaging's impact on traumatic brain injury imaging continues to expand. MR imaging has shown superiority to CT for certain traumatic processes, such as diffuse axonal injury, cerebral contusion, and infarction. Magnetic resonance angiography and magnetic resonance venography allow emergent vascular imaging for patients that should avoid ionizing radiation or intravenous contrast. PMID:27150321

  5. Recent advances in cardiac magnetic resonance

    PubMed Central

    Greulich, Simon; Arai, Andrew E.; Sechtem, Udo; Mahrholdt, Heiko

    2016-01-01

    Cardiac magnetic resonance (CMR) is a non-invasive imaging modality that has rapidly emerged during the last few years and has become a valuable, well-established clinical tool. Beside the evaluation of anatomy and function, CMR has its strengths in providing detailed non-invasive myocardial tissue characterization, for which it is considered the current diagnostic gold standard. Late gadolinium enhancement (LGE), with its capability to detect necrosis and to separate ischemic from non-ischemic cardiomyopathies by distinct LGE patterns, offers unique clinical possibilities. The presence of LGE has also proven to be a good predictor of an adverse outcome in various studies. T2-weighted (T2w) images, which are supposed to identify areas of edema and inflammation, are another CMR approach to tissue characterization. However, T2w images have not held their promise owing to several technical limitations and potential physiological concerns. Newer mapping techniques may overcome some of these limitations: they assess quantitatively myocardial tissue properties in absolute terms and show promising results in studies for characterization of diffuse fibrosis (T1 mapping) and/or inflammatory processes (T2 mapping). However, these techniques are still research tools and are not part of the clinical routine yet. T2* CMR has had significant impact in the management of thalassemia because it is possible to image the amount of iron in the heart and the liver, improving both diagnostic imaging and the management of patients with thalassemia. CMR findings frequently have clinical impact on further patient management, and CMR seems to be cost effective in the clinical routine.

  6. Wide-range dynamic magnetic resonance elastography.

    PubMed

    Riek, Kerstin; Klatt, Dieter; Nuzha, Hassan; Mueller, Susanne; Neumann, Ulf; Sack, Ingolf; Braun, Jürgen

    2011-04-29

    Tissue mechanical parameters have been shown to be highly sensitive to disease by elastography. Magnetic resonance elastography (MRE) in the human body relies on the low-dynamic range of tissue mechanics <100 Hz. In contrast, MRE suited for investigations of mice or small tissue samples requires vibration frequencies 10-20 times higher than those used in human MRE. The dispersion of the complex shear modulus (G(⁎)) prevents direct comparison of elastography data at different frequency bands and, consequently, frequency-independent viscoelastic models that fit to G(*) over a wide dynamic range have to be employed. This study presents data of G(*) of samples of agarose gel, liver, brain, and muscle measured by high-resolution MRE in a 7T-animal scanner at 200-800 Hz vibration frequency. Material constants μ and α according to the springpot model and related to shear elasticity and slope of the G(*)-dispersion were determined. Both μ and α of calf brain and bovine liver were found to be similar, while a sample of fibrotic human liver (METAVIR score of 3) displayed about fifteen times higher shear elasticity, similar to μ of bovine muscle measured in muscle fiber direction. α was the highest in fibrotic liver, followed by normal brain and liver, while muscle had the lowest α-values of all biological samples investigated in this study. As expected, the least G(*)-dispersion was seen in soft gel. The proposed technique of wide-range dynamic MRE can provide baseline data for both human MRE and high-dynamic MRE for better understanding tissue mechanics of different tissue structures. PMID:21295305

  7. Fetal magnetic resonance imaging in obstetric practice

    PubMed Central

    Köşüş, Aydın; Köşüş, Nermin; Usluoğulları, Betül; Duran, Müzeyyen; Turhan, Nilgün Öztürk; Tekşam, Mehmet

    2011-01-01

    Ultrasonography (USG) is the primary imaging method for prenatal diagnosis of fetal abnormalities since its discovery. Although it is the primary method of fetal imaging, it cannot provide sufficient information about the fetus in some conditions such as maternal obesity, oligohydramnios and engagement of the fetal head. At this stage, magnetic resonance imaging (MRI) facilitates examination by providing more specific information. The need and importance of fetal MRI applications further increased by the intrauterine surgery which is currently gaining popularity. Some advantages of fetal MRI over USG are the good texture of contrast, a greater study area and visualization of the lesion and neighbourhood relations, independence of the operators. Also it is not affected by maternal obesity and severe oligohydramnios. However, MRI is inadequate in detecting fetal limb and cardiac abnormalities when compared to USG. MRI is not used routinely in pregnancy. It is used in situations where nonionizing imaging methods are inadequate or ionizing radiation is required in pregnant women. It is not recommended during the first trimester. Contrast agent (Godalinium) is not used during pregnancy. It is believed that MRI is not harmful to the fetus, although the biological risk of MRI application is not known. MRI technique is superior to USG in the detection of corpus callosum dysgenesis, third-trimester evaluation of posterior fossa malformations, bilateral renal agenesis, diaphragmatic hernia and assessment of lung maturation. Especially, it is the method of choice for evaluation of central nervous system (CNS) abnormalities. Fetal MRI has a complementary role with USG. It provides important information for prenatal diagnosis, increases diagnostic accuracy, and in turn affects the prenatal treatment, prenatal interventions and birth plan. PMID:24591956

  8. Functional magnetic resonance imaging of the lung.

    PubMed

    Biederer, J; Heussel, C P; Puderbach, M; Wielpuetz, M O

    2014-02-01

    Beyond being a substitute for X-ray, computed tomography, and scintigraphy, magnetic resonance imaging (MRI) inherently combines morphologic and functional information more than any other technology. Lung perfusion: The most established method is first-pass contrast-enhanced imaging with bolus injection of gadolinium chelates and time-resolved gradient-echo (GRE) sequences covering the whole lung (1 volume/s). Images are evaluated visually or semiquantitatively, while absolute quantification remains challenging due to the nonlinear relation of T1-shortening and contrast material concentration. Noncontrast-enhanced perfusion imaging is still experimental, either based on arterial spin labeling or Fourier decomposition. The latter is used to separate high- and low-frequency oscillations of lung signal related to the effects of pulsatile blood flow. Lung ventilation: Using contrast-enhanced first-pass perfusion, lung ventilation deficits are indirectly identified by hypoxic vasoconstriction. More direct but still experimental approaches use either inhalation of pure oxygen, an aerosolized contrast agent, or hyperpolarized noble gases. Fourier decomposition MRI based on the low-frequency lung signal oscillation allows for visualization of ventilation without any contrast agent. Respiratory mechanics: Time-resolved series with high background signal such as GRE or steady-state free precession visualize the movement of chest wall, diaphragm, mediastinum, lung tissue, tracheal wall, and tumor. The assessment of volume changes allows drawing conclusions on regional ventilation. With this arsenal of functional imaging capabilities at high spatial and temporal resolution but without radiation burden, MRI will find its role in regional functional lung analysis and will therefore overcome the sensitivity of global lung function analysis for repeated short-term treatment monitoring. PMID:24481761

  9. Magnetic Resonance Imaging in Postprostatectomy Radiotherapy Planning

    SciTech Connect

    Sefrova, Jana; Odrazka, Karel; Paluska, Petr; Belobradek, Zdenek; Brodak, Milos; Dolezel, Martin; Prosvic, Petr; Macingova, Zuzana; Vosmik, Milan; Hoffmann, Petr; Louda, Miroslav; Nejedla, Anna

    2012-02-01

    Purpose: To investigate whether the use of magnetic resonance imaging (MRI) in prostate bed treatment planning could influence definition of the clinical target volume (CTV) and organs at risk. Methods and Materials: A total of 21 consecutive patients referred for prostate bed radiotherapy were included in the present retrospective study. The CTV was delineated according to the European Organization for Research and Treatment of Cancer recommendations on computed tomography (CT) and T{sub 1}-weighted (T{sub 1}w) and T{sub 2}-weighted (T{sub 2}w) MRI. The CTV magnitude, agreement, and spatial differences were evaluated on the planning CT scan after registration with the MRI scans. Results: The CTV was significantly reduced on the T{sub 1}w and T{sub 2}w MRI scans (13% and 9%, respectively) compared with the CT scans. The urinary bladder was drawn smaller on the CT scans and the rectum was smaller on the MRI scans. On T{sub 1}w MRI, the rectum and urinary bladder were delineated larger than on T{sub 2}w MRI. Minimal agreement was observed between the CT and T{sub 2}w images. The main spatial differences were measured in the superior and superolateral directions in which the CTV on the MRI scans was 1.8-2.9 mm smaller. In the posterior and inferior border, no difference was seen between the CT and T{sub 1}w MRI scans. On the T{sub 2}w MRI scans, the CTV was larger in these directions (by 1.3 and 1.7 mm, respectively). Conclusions: The use of MRI in postprostatectomy radiotherapy planning resulted in a reduction of the CTV. The main differences were found in the superior part of the prostate bed. We believe T{sub 2}w MRI enables more precise definition of prostate bed CTV than conventional planning CT.

  10. Tools for cardiovascular magnetic resonance imaging

    PubMed Central

    Krishnamurthy, Ramkumar; Cheong, Benjamin

    2014-01-01

    In less than fifteen years, as a non-invasive imaging option, cardiovascular MR has grown from a being a mere curiosity to becoming a widely used clinical tool for evaluating cardiovascular disease. Cardiovascular magnetic resonance imaging (CMRI) is now routinely used to study myocardial structure, cardiac function, macro vascular blood flow, myocardial perfusion, and myocardial viability. For someone entering the field of cardiac MR, this rapid pace of development in the field of CMRI might make it difficult to identify a cohesive starting point. In this brief review, we have attempted to summarize the key cardiovascular imaging techniques that have found widespread clinical acceptance. In particular, we describe the essential cardiac and respiratory gating techniques that form the backbone of all cardiovascular imaging methods. It is followed by four sections that discuss: (I) the gradient echo techniques that are used to assess ventricular function; (II) black-blood turbo spin echo (SE) methods used for morphologic assessment of the heart; (III) phase-contrast based techniques for the assessment of blood flow; and (IV) CMR methods for the assessment of myocardial ischemia and viability. In each section, we briefly summarize technical considerations relevant to the clinical use of these techniques, followed by practical information for its clinical implementation. In each of those four areas, CMRI is considered either as the benchmark imaging modality against which the diagnostic performance of other imaging modalities are compared against, or provides a complementary capability to existing imaging techniques. We have deliberately avoided including cutting-edge CMR imaging techniques practiced at few academic centers, and restricted our discussion to methods that are widely used and are likely to be available in a clinical setting. Our hope is that this review would propel an interested reader toward more comprehensive reviews in the literature. PMID:24834409

  11. Fetal magnetic resonance imaging in obstetric practice.

    PubMed

    Köşüş, Aydın; Köşüş, Nermin; Usluoğulları, Betül; Duran, Müzeyyen; Turhan, Nilgün Öztürk; Tekşam, Mehmet

    2011-01-01

    Ultrasonography (USG) is the primary imaging method for prenatal diagnosis of fetal abnormalities since its discovery. Although it is the primary method of fetal imaging, it cannot provide sufficient information about the fetus in some conditions such as maternal obesity, oligohydramnios and engagement of the fetal head. At this stage, magnetic resonance imaging (MRI) facilitates examination by providing more specific information. The need and importance of fetal MRI applications further increased by the intrauterine surgery which is currently gaining popularity. Some advantages of fetal MRI over USG are the good texture of contrast, a greater study area and visualization of the lesion and neighbourhood relations, independence of the operators. Also it is not affected by maternal obesity and severe oligohydramnios. However, MRI is inadequate in detecting fetal limb and cardiac abnormalities when compared to USG. MRI is not used routinely in pregnancy. It is used in situations where nonionizing imaging methods are inadequate or ionizing radiation is required in pregnant women. It is not recommended during the first trimester. Contrast agent (Godalinium) is not used during pregnancy. It is believed that MRI is not harmful to the fetus, although the biological risk of MRI application is not known. MRI technique is superior to USG in the detection of corpus callosum dysgenesis, third-trimester evaluation of posterior fossa malformations, bilateral renal agenesis, diaphragmatic hernia and assessment of lung maturation. Especially, it is the method of choice for evaluation of central nervous system (CNS) abnormalities. Fetal MRI has a complementary role with USG. It provides important information for prenatal diagnosis, increases diagnostic accuracy, and in turn affects the prenatal treatment, prenatal interventions and birth plan. PMID:24591956

  12. Magnetic Resonance Imaging–guided Vascular Interventions

    PubMed Central

    Ozturk, Cengizhan; Guttman, Michael; McVeigh, Elliot R.; Lederman, Robert J.

    2007-01-01

    Magnetic resonance imaging (MRI), which provides superior soft-tissue imaging and no known harmful effects, has the potential as an alternative modality to guide various medical interventions. This review will focus on MR-guided endovascular interventions and present its current state and future outlook. In the first technical part, enabling technologies such as developments in fast imaging, catheter devices, and visualization techniques are examined. This is followed by a clinical survey that includes proof-of-concept procedures in animals and initial experience in human subjects. In preclinical experiments, MRI has already proven to be valuable. For example, MRI has been used to guide and track targeted cell delivery into or around myocardial infarctions, to guide atrial septal puncture, and to guide the connection of portal and systemic venous circulations. Several investigational MR-guided procedures have already been reported in patients, such as MR-guided cardiac catheterization, invasive imaging of peripheral artery atheromata, selective intraarterial MR angiography, and preliminary angioplasty and stent placement. In addition, MR-assisted transjugular intrahepatic portosystemic shunt procedures in patients have been shown in a novel hybrid double-doughnut x-ray/MRI system. Numerous additional investigational human MR-guided endovascular procedures are now underway in several medical centers around the world. There are also significant hurdles: availability of clinical-grade devices, device-related safety issues, challenges to patient monitoring, and acoustic noise during imaging. The potential of endovascular interventional MRI is great because as a single modality, it combines 3-dimensional anatomic imaging, device localization, hemodynamics, tissue composition, and function. PMID:16924170

  13. Small Animal Imaging with Magnetic Resonance Microscopy

    PubMed Central

    Driehuys, Bastiaan; Nouls, John; Badea, Alexandra; Bucholz, Elizabeth; Ghaghada, Ketan; Petiet, Alexandra; Hedlund, Laurence W.

    2009-01-01

    Small animal magnetic resonance microscopy (MRM) has evolved significantly from testing the boundaries of imaging physics to its expanding use today as a tool in non-invasive biomedical investigations. This review is intended to capture the state-of-the-art in MRM for scientists who may be unfamiliar with this modality, but who want to apply its capabilities to their research. We therefore include a brief review of MR concepts and methods of animal handling and support before covering a range of MRM applications including the heart, lung, brain, and the emerging field of MR histology. High-resolution anatomical imaging reveals increasingly exquisite detail in healthy animals and subtle architectural aberrations that occur in genetically altered models. Resolution of 100 µm in all dimensions is now routinely attained in living animals, and 10 µm3 is feasible in fixed specimens. Such images almost rival conventional histology while allowing the object to be viewed interactively in any plane. MRM is now increasingly used to provide functional information in living animals. Images of the beating heart, breathing lung, and functioning brain can be recorded. While clinical MRI focuses on diagnosis, MRM is used to reveal fundamental biology or to non-invasively measure subtle changes in the structure or function of organs during disease progression or in response to experimental therapies. The ability of MRM to provide a detailed functional and anatomical picture in rats and mice, and to track this picture over time, makes it a promising platform with broad applications in biomedical research. PMID:18172332

  14. Pressure-driven amplification and penetration of resonant magnetic perturbations

    NASA Astrophysics Data System (ADS)

    Loizu, J.; Hudson, S. R.; Helander, P.; Lazerson, S. A.; Bhattacharjee, A.

    2016-05-01

    We show that a resonant magnetic perturbation applied to the boundary of an ideal plasma screw-pinch equilibrium with nested surfaces can penetrate inside the resonant surface and into the core. The response is significantly amplified with increasing plasma pressure. We present a rigorous verification of nonlinear equilibrium codes against linear theory, showing excellent agreement.

  15. Patellar tendinitis: the significance of magnetic resonance imaging findings.

    PubMed

    Shalaby, M; Almekinders, L C

    1999-01-01

    We evaluated the significance of magnetic resonance imaging findings in patients with patellar tendinitis. Midline sagittal magnetic resonance images were taken of 12 knees from 10 patients and of 17 knees from 15 age- and activity-matched subjects who underwent imaging for reasons other than patellar tendinitis. Of the 12 magnetic resonance imaging scans of knees with clinical patellar tendinitis, 3 (25%) exhibited no defect and only 7 (58%) had unequivocal intratendinous lesions. Among the 17 scans of subjects without clinical patellar tendinitis, 5 (34%) showed no defect and 4 (24%) had unequivocal intratendinous lesions. Proximal tendon width was significantly larger for the tendinitis patient group (5.0 +/- 1.7 mm versus 3.9 +/- 1.0 mm), although considerable overlap was present. All subjects with unequivocal intratendinous signal changes had a significantly longer nonarticular inferior patellar pole and were significantly older (38.1 years versus 26.8 years). Only Blazina stage III lesions were associated with abnormal findings on magnetic resonance imaging. As a whole, the sensitivity and specificity of magnetic resonance imaging was 75% and 29%, respectively. In younger patients with relatively mild symptoms, magnetic resonance imaging did not show significant changes; in older, active patients changes may be present in asymptomatic knees. PMID:10352771

  16. Probe-Sample Coupling in the Magnetic Resonance Force Microscope

    NASA Astrophysics Data System (ADS)

    Suter, A.; Pelekhov, D. V.; Roukes, M. L.; Hammel, P. C.

    2002-02-01

    The magnetic resonance force microscope (MRFM) provides a route to achieving scanned probe magnetic resonance imaging with extremely high spatial resolution. Achieving this capability will require understanding the force exerted on a microscopic magnetic probe by a spatially extended sample over which the probe is scanned. Here we present a detailed analysis of this interaction between probe and sample. We focus on understanding the situation where the micromagnet mounted on the mechanical resonator generates a very inhomogeneous magnetic field and is scanned over a sample with at least one spatial dimension much larger than that of the micromagnet. This situation differs quite significantly from the conditions under which most MRFM experiments have been carried out where the sample is mounted on the mechanical resonator and placed in a rather weak magnetic field gradient. In addition to the concept of a sensitive slice (the spatial region where the magnetic resonance condition is met) it is valuable to map the forces exerted on the probe by spins at various locations; this leads to the concept of the force slice (the region in which spins exert force on the resonator). Results of this analysis, obtained both analytically and numerically, will be qualitatively compared with an initial experimental finding from an EPR-MRFM experiment carried out on DPPH at 4 K.

  17. Probe--sample coupling in the magnetic resonance force microscope.

    PubMed

    Suter, A; Pelekhov, D V; Roukes, M L; Hammel, P C

    2002-02-01

    The magnetic resonance force microscope (MRFM) provides a route to achieving scanned probe magnetic resonance imaging with extremely high spatial resolution. Achieving this capability will require understanding the force exerted on a microscopic magnetic probe by a spatially extended sample over which the probe is scanned. Here we present a detailed analysis of this interaction between probe and sample. We focus on understanding the situation where the micromagnet mounted on the mechanical resonator generates a very inhomogeneous magnetic field and is scanned over a sample with at least one spatial dimension much larger than that of the micromagnet. This situation differs quite significantly from the conditions under which most MRFM experiments have been carried out where the sample is mounted on the mechanical resonator and placed in a rather weak magnetic field gradient. In addition to the concept of a sensitive slice (the spatial region where the magnetic resonance condition is met) it is valuable to map the forces exerted on the probe by spins at various locations; this leads to the concept of the force slice (the region in which spins exert force on the resonator). Results of this analysis, obtained both analytically and numerically, will be qualitatively compared with an initial experimental finding from an EPR-MRFM experiment carried out on DPPH at 4 K. PMID:11846579

  18. Single Molecule Magnetic Force Detection with a Carbon Nanotube Resonator

    NASA Astrophysics Data System (ADS)

    Willick, Kyle; Walker, Sean; Baugh, Jonathan

    2015-03-01

    Single molecule magnets (SMMs) sit at the boundary between macroscopic magnetic behaviour and quantum phenomena. Detecting the magnetic moment of an individual SMM would allow exploration of this boundary, and could enable technological applications based on SMMs such as quantum information processing. Detection of these magnetic moments remains an experimental challenge, particularly at the time scales of relaxation and decoherence. We present a technique for sensitive magnetic force detection that should permit such measurements. A suspended carbon nanotube (CNT) mechanical resonator is combined with a magnetic field gradient generated by a ferromagnetic gate electrode, which couples the magnetic moment of a nanomagnet to the resonant motion of the CNT. Numerical calculations of the mechanical resonance show that resonant frequency shifts on the order of a few kHz arise due to single Bohr magneton changes in magnetic moment. A signal-to-noise analysis based on thermomechanical noise shows that magnetic switching at the level of a Bohr magneton can be measured in a single shot on timescales as short as 10 μs. This sensitivity should enable studies of the spin dynamics of an isolated SMM, within the spin relaxation timescales for many available SMMs. Supported by NSERC.

  19. Ferromagnetic resonance in ϵ-Co magnetic composites.

    PubMed

    Chalapat, Khattiya; Timonen, Jaakko V I; Huuppola, Maija; Koponen, Lari; Johans, Christoffer; Ras, Robin H A; Ikkala, Olli; Oksanen, Markku A; Seppälä, Eira; Paraoanu, G S

    2014-12-01

    We investigate the electromagnetic properties of assemblies of nanoscale ϵ-cobalt crystals with size range between 5 to 35 nm, embedded in a polystyrene matrix, at microwave (1-12 GHz) frequencies. We investigate the samples by transmission electron microscopy imaging, demonstrating that the particles aggregate and form chains and clusters. By using a broadband coaxial-line method, we extract the magnetic permeability in the frequency range from 1 to 12 GHz, and we study the shift of the ferromagnetic resonance (FMR) with respect to an externally applied magnetic field. We find that the zero-magnetic field ferromagnetic resonant peak shifts towards higher frequencies at finite magnetic fields, and the magnitude of complex permeability is reduced. At fields larger than 2.5 kOe the resonant frequency changes linearly with the applied magnetic field, demonstrating the transition to a state in which the nanoparticles become dynamically decoupled. In this regime, the particles inside clusters can be treated as non-interacting, and the peak position can be predicted from Kittel's FMR theory for non-interacting uniaxial spherical particles combined with the Landau-Lifshitz-Gilbert equation. In contrast, at low magnetic fields this magnetic order breaks down and the resonant frequency in zero magnetic field reaches a saturation value reflecting the interparticle interactions as resulting from aggregation. Our results show that the electromagnetic properties of these composite materials can be tuned by external magnetic fields and by changes in the aggregation structure. PMID:25397945

  20. Magnetic resonance velocimetry: applications of magnetic resonance imaging in the measurement of fluid motion

    NASA Astrophysics Data System (ADS)

    Elkins, Christopher J.; Alley, Marcus T.

    2007-12-01

    Magnetic resonance velocimetry (MRV) is a non-invasive technique capable of measuring the three-component mean velocity field in complex three-dimensional geometries with either steady or periodic boundary conditions. The technique is based on the phenomenon of nuclear magnetic resonance (NMR) and works in conventional magnetic resonance imaging (MRI) magnets used for clinical imaging. Velocities can be measured along single lines, in planes, or in full 3D volumes with sub-millimeter resolution. No optical access or flow markers are required so measurements can be obtained in clear or opaque MR compatible flow models and fluids. Because of its versatility and the widespread availability of MRI scanners, MRV is seeing increasing application in both biological and engineering flows. MRV measurements typically image the hydrogen protons in liquid flows due to the relatively high intrinsic signal-to-noise ratio (SNR). Nonetheless, lower SNR applications such as fluorine gas flows are beginning to appear in the literature. MRV can be used in laminar and turbulent flows, single and multiphase flows, and even non-isothermal flows. In addition to measuring mean velocity, MRI techniques can measure turbulent velocities, diffusion coefficients and tensors, and temperature. This review surveys recent developments in MRI measurement techniques primarily in turbulent liquid and gas flows. A general description of MRV provides background for a discussion of its accuracy and limitations. Techniques for decreasing scan time such as parallel imaging and partial k-space sampling are discussed. MRV applications are reviewed in the areas of physiology, biology, and engineering. Included are measurements of arterial blood flow and gas flow in human lungs. Featured engineering applications include the scanning of turbulent flows in complex geometries for CFD validation, the rapid iterative design of complex internal flow passages, velocity and phase composition measurements in

  1. Magnetically-controlled Fano resonance in wavefunction-coupled QPCs

    NASA Astrophysics Data System (ADS)

    Kang, Myoung-Gu

    In this thesis, we describe the observation of a resonant interaction between coupled quantum point contacts (QPCs) that we attribute to a Fano resonance, caused by the self-consistent formation of a bound-state (BS) in one of the QPCs. The presence of this BS (in the "swept QPC") is detected by making measurements of the conductance of the other QPC, which therefore serves as a detector. A key feature of our work is the demonstration of a strong modulation of the detector resonance by applying a perpendicular magnetic field (B⊥). This induces a distinct asymmetry (with respect to magnetic-field reversal) in the magneto-conductance of the detector, which is shown to be due to the influence magnetic electron focusing. In this effect, the electron trajectories correspond to classical skipping orbits, which undergo complete motion due to the high mobility of the two-dimensional electron gas. At even higher B⊥, the detector resonance, which at zero magnetic field is only weakly asymmetric, evolves into the classic, highly asymmetric, Fano form. Such asymmetry indicates that the nonresonant contribution to detector resonance becomes comparable to the resonant one at high fields. We explain these results in terms of two key properties of quantum-dot eigenstates in a magnetic field, namely: the tendency for their wavefunctions to be compressed towards the center of the quantum-dot potential, and; that for their eigenenergies to increase due to the associated enhancement in the effective degree of confinement. In this thesis, we confirm these ideas by performing a Fock-Darwin analysis to account for the evolution of the detector Fano resonance in the magnetic field. The strong modulations of the Fano resonance that we observe as a function of B⊥ are shown to represent a new manifestation of this ubiquitous resonance.

  2. Least Squares Magnetic-Field Optimization for Portable Nuclear Magnetic Resonance Magnet Design

    SciTech Connect

    Paulsen, Jeffrey L; Franck, John; Demas, Vasiliki; Bouchard, Louis-S.

    2008-03-27

    Single-sided and mobile nuclear magnetic resonance (NMR) sensors have the advantages of portability, low cost, and low power consumption compared to conventional high-field NMR and magnetic resonance imaging (MRI) systems. We present fast, flexible, and easy-to-implement target field algorithms for mobile NMR and MRI magnet design. The optimization finds a global optimum ina cost function that minimizes the error in the target magnetic field in the sense of least squares. When the technique is tested on a ring array of permanent-magnet elements, the solution matches the classical dipole Halbach solution. For a single-sided handheld NMR sensor, the algorithm yields a 640 G field homogeneous to 16 100 ppm across a 1.9 cc volume located 1.5 cm above the top of the magnets and homogeneous to 32 200 ppm over a 7.6 cc volume. This regime is adequate for MRI applications. We demonstrate that the homogeneous region can be continuously moved away from the sensor by rotating magnet rod elements, opening the way for NMR sensors with adjustable"sensitive volumes."

  3. Electron paramagnetic resonance of nitroxide-doped magnetic fluids

    NASA Astrophysics Data System (ADS)

    Morais, P. C.; Alonso, A.; Silva, O.; Buske, N.

    2002-11-01

    Electron paramagnetic resonance was used to investigate surface-coated magnetite-based magnetic fluids doped with TEMPOL. Two magnetic fluid samples, having magnetite nanoparticles with average diameter of 94 Å and coated with different coating layers (lauric acid plus ethoxylated polyalcohol in one case and oleoylsarcosine in the other case), were doped with TEMPOL (6 mM and pH 7.4) and investigated as a function of the nanoparticle concentration. The resonance field and the resonance linewidth both scale linearly with the nanoparticle concentration.

  4. Magnetic Resonance Imaging (MRI): Dynamic Pelvic Floor

    MedlinePlus

    ... a powerful magnetic field, radio waves and a computer to produce detailed pictures of the pelvic floor, ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ...

  5. Resonant Raman scattering from silicon nanoparticles enhanced by magnetic response

    NASA Astrophysics Data System (ADS)

    Dmitriev, Pavel A.; Baranov, Denis G.; Milichko, Valentin A.; Makarov, Sergey V.; Mukhin, Ivan S.; Samusev, Anton K.; Krasnok, Alexander E.; Belov, Pavel A.; Kivshar, Yuri S.

    2016-05-01

    Enhancement of optical response with high-index dielectric nanoparticles is attributed to the excitation of their Mie-type magnetic and electric resonances. Here we study Raman scattering from crystalline silicon nanoparticles and reveal that magnetic dipole modes have a much stronger effect on the scattering than electric modes of the same order. We demonstrate experimentally a 140-fold enhancement of the Raman signal from individual silicon spherical nanoparticles at the magnetic dipole resonance. Our results confirm the importance of the optically-induced magnetic response of subwavelength dielectric nanoparticles for enhancing light-matter interactions.Enhancement of optical response with high-index dielectric nanoparticles is attributed to the excitation of their Mie-type magnetic and electric resonances. Here we study Raman scattering from crystalline silicon nanoparticles and reveal that magnetic dipole modes have a much stronger effect on the scattering than electric modes of the same order. We demonstrate experimentally a 140-fold enhancement of the Raman signal from individual silicon spherical nanoparticles at the magnetic dipole resonance. Our results confirm the importance of the optically-induced magnetic response of subwavelength dielectric nanoparticles for enhancing light-matter interactions. Electronic supplementary information (ESI) available. See DOI: 10.1039/c5nr07965a

  6. High-Resolution Nuclear Magnetic Resonance of Solids.

    ERIC Educational Resources Information Center

    Maciel, Gary E.

    1984-01-01

    Examines recent developments in techniques for obtaining high-resolution nuclear magnetic resonance (NMR) spectra on solid samples, discussing the kinds of applications for which these techniques are well suited. Also discusses the characteristics of NMR of solids and generating magnetization for NMR in solids. (JN)

  7. The Nobel Prize in Medicine for Magnetic Resonance Imaging

    ERIC Educational Resources Information Center

    Fry, Charles G.

    2004-01-01

    Nobel Prize in Medicine awarded in December 2003 to chemist Paul C. Lauterbur and physicist Peter Mansfield for the development of magnetic resonance imaging (MRI), a long overdue recognition of the huge impact MRI has had in medical diagnostics and research is mentioned. MRI was derived, and remains an extension of nuclear magnetic resonance…

  8. Parametric resonance induced chaos in magnetic damped driven pendulum

    NASA Astrophysics Data System (ADS)

    Khomeriki, Giorgi

    2016-07-01

    A damped driven pendulum with a magnetic driving force, appearing from a solenoid, where ac current flows is considered. The solenoid acts on the magnet, which is located at a free end of the pendulum. In this system the existence and interrelation of chaos and parametric resonance is theoretically examined. Derived analytical results are supported by numerical simulations and conducted experiments.

  9. Terahertz Magnetic Mirror Realized with Dielectric Resonator Antennas.

    PubMed

    Headland, Daniel; Nirantar, Shruti; Withayachumnankul, Withawat; Gutruf, Philipp; Abbott, Derek; Bhaskaran, Madhu; Fumeaux, Christophe; Sriram, Sharath

    2015-11-25

    Single-crystal silicon is bonded to a metal-coated substrate and etched in order to form an array of microcylinder passive terahertz dielectric resonator antennas (DRAs). The DRAs exhibit a magnetic response, and hence the array behaves as an efficient artificial magnetic conductor (AMC), with potential for terahertz antenna and sensing applications. PMID:26450363

  10. Structure of magnetic resonance in 87Rb atoms

    NASA Astrophysics Data System (ADS)

    Kozlov, A. N.; Zibrov, S. A.; Zibrov, A. A.; Yudin, V. I.; Taichenachev, A. V.; Yakovlev, V. P.; Tsygankov, E. A.; Zibrov, A. S.; Vassiliev, V. V.; Velichansky, V. L.

    2016-05-01

    Magnetic resonance at the F g = 1 rightleftarrows F e = 1 transition of the D 1 line in 87Rb has been studied with pumping and detection by linearly polarized radiation and detection at the double frequency of the radiofrequency field. The intervals of allowed values of the static and alternating magnetic fields in which magnetic resonance has a single maximum have been found. The structure appearing beyond these intervals has been explained. It has been shown that the quadratic Zeeman shift is responsible for the three-peak structure of resonance; the radiofrequency shift results in the appearance of additional extrema in resonance, which can be used to determine the relaxation constant Γ2. The possibility of application in magnetometry has been discussed.

  11. Tunable resonant transmission of electromagnetic waves through a magnetized plasma.

    PubMed

    Kee, Chul-Sik; Li, Shou-Zhe; Kim, Kihong; Lim, H

    2003-03-01

    We theoretically investigate the resonant transmission of circularly polarized electromagnetic waves in the electromagnetic stop band of a magnetized plasma slab using the invariant embedding method. The frequency and quality factor of the resonant mode for the right-handed (left-handed) circularly polarized wave created by inserting a dielectric layer into the plasma increase (decrease) as the magnitude of the external magnetic field increases. These phenomena are compared with the characteristics of resonant modes in metallic and dielectric Fabry-Perot resonators to show that they are due to the change of plasma reflectivity. We also discuss the damping effect due to the collisions of the constituent particles of the plasma on the resonant transmission of circularly polarized waves. PMID:12689184

  12. Accelerated nanoscale magnetic resonance imaging through phase multiplexing

    SciTech Connect

    Moores, B. A.; Eichler, A. Takahashi, H.; Navaretti, P.; Degen, C. L.; Tao, Y.

    2015-05-25

    We report a method for accelerated nanoscale nuclear magnetic resonance imaging by detecting several signals in parallel. Our technique relies on phase multiplexing, where the signals from different nuclear spin ensembles are encoded in the phase of an ultrasensitive magnetic detector. We demonstrate this technique by simultaneously acquiring statistically polarized spin signals from two different nuclear species ({sup 1}H, {sup 19}F) and from up to six spatial locations in a nanowire test sample using a magnetic resonance force microscope. We obtain one-dimensional imaging resolution better than 5 nm, and subnanometer positional accuracy.

  13. Accelerated nanoscale magnetic resonance imaging through phase multiplexing

    NASA Astrophysics Data System (ADS)

    Moores, B. A.; Eichler, A.; Tao, Y.; Takahashi, H.; Navaretti, P.; Degen, C. L.

    2015-05-01

    We report a method for accelerated nanoscale nuclear magnetic resonance imaging by detecting several signals in parallel. Our technique relies on phase multiplexing, where the signals from different nuclear spin ensembles are encoded in the phase of an ultrasensitive magnetic detector. We demonstrate this technique by simultaneously acquiring statistically polarized spin signals from two different nuclear species (1H, 19F) and from up to six spatial locations in a nanowire test sample using a magnetic resonance force microscope. We obtain one-dimensional imaging resolution better than 5 nm, and subnanometer positional accuracy.

  14. Spin wave resonance detection using magnetic tunnel junction structure

    NASA Astrophysics Data System (ADS)

    Bi, Chong; Fan, Xin; Pan, Liqing; Kou, Xiaoming; Wu, Jun; Yang, Qinghui; Zhang, Huaiwu; Xiao, John Q.

    2011-11-01

    We have demonstrated that spin wave resonance in a permalloy microstrip can be detected by an electrical method based on magnetic tunnel junction structures. The detection method promises high spatial resolution and sensitivity. Both even and odd spin wave resonance modes can be clearly observed in a permalloy microstrip. The spin wave induced voltage is proportional to the input microwave power at each resonance mode. Data analysis using the model of quantized dipole-exchange spin wave resonance suggests the edge pinning of spin wave sensitively depends on the order of the spin wave mode, as well as on the excitation frequency for modes of the higher order.

  15. Spin microscope based on optically detected magnetic resonance

    SciTech Connect

    Berman, Gennady P.; Chernobrod, Boris M.

    2009-11-10

    The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of impaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

  16. Spin microscope based on optically detected magnetic resonance

    SciTech Connect

    Berman, Gennady P.; Chernobrod, Boris M.

    2010-06-29

    The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

  17. Spin microscope based on optically detected magnetic resonance

    SciTech Connect

    Berman, Gennady P.; Chernobrod, Boris M.

    2010-07-13

    The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

  18. Spin microscope based on optically detected magnetic resonance

    SciTech Connect

    Berman, Gennady P.; Chernobrod, Boris M.

    2009-10-27

    The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

  19. Spin microscope based on optically detected magnetic resonance

    DOEpatents

    Berman, Gennady P.; Chernobrod, Boris M.

    2007-12-11

    The invention relates to scanning magnetic microscope which has a photoluminescent nanoprobe implanted in the tip apex of an atomic force microscope (AFM), a scanning tunneling microscope (STM) or a near-field scanning optical microscope (NSOM) and exhibits optically detected magnetic resonance (ODMR) in the vicinity of unpaired electron spins or nuclear magnetic moments in the sample material. The described spin microscope has demonstrated nanoscale lateral resolution and single spin sensitivity for the AFM and STM embodiments.

  20. Catheter steering using a Magnetic Resonance Imaging system.

    PubMed

    Lalande, Viviane; Gosselin, Frederick P; Martel, Sylvain

    2010-01-01

    A catheter is successfully bent and steered by applying magnetic gradients inside a Magnetic Resonance Imaging system (MRI). One to three soft ferromagnetic spheres are attached at the distal tip of the catheter with different spacing between the spheres. Depending on the interactions between the spheres, progressive or discontinuous/jumping displacement was observed for increasing magnetic load. This phenomenon is accurately predicted by a simple theoretical dipole interaction model. PMID:21096567

  1. Quantum transport in coupled resonators enclosed synthetic magnetic flux

    NASA Astrophysics Data System (ADS)

    Jin, L.

    2016-07-01

    Quantum transport properties are instrumental to understanding quantum coherent transport processes. Potential applications of quantum transport are widespread, in areas ranging from quantum information science to quantum engineering, and not restricted to quantum state transfer, control and manipulation. Here, we study light transport in a ring array of coupled resonators enclosed synthetic magnetic flux. The ring configuration, with an arbitrary number of resonators embedded, forms a two-arm Aharonov-Bohm interferometer. The influence of magnetic flux on light transport is investigated. Tuning the magnetic flux can lead to resonant transmission, while half-integer magnetic flux quantum leads to completely destructive interference and transmission zeros in an interferometer with two equal arms.

  2. Nuclear magnetic resonance spectroscopy with single spin sensitivity

    PubMed Central

    Müller, C.; Kong, X.; Cai, J.-M.; Melentijević, K.; Stacey, A.; Markham, M.; Twitchen, D.; Isoya, J.; Pezzagna, S.; Meijer, J.; Du, J. F.; Plenio, M. B.; Naydenov, B.; McGuinness, L. P.; Jelezko, F.

    2014-01-01

    Nuclear magnetic resonance spectroscopy and magnetic resonance imaging at the ultimate sensitivity limit of single molecules or single nuclear spins requires fundamentally new detection strategies. The strong coupling regime, when interaction between sensor and sample spins dominates all other interactions, is one such strategy. In this regime, classically forbidden detection of completely unpolarized nuclei is allowed, going beyond statistical fluctuations in magnetization. Here we realize strong coupling between an atomic (nitrogen–vacancy) sensor and sample nuclei to perform nuclear magnetic resonance on four 29Si spins. We exploit the field gradient created by the diamond atomic sensor, in concert with compressed sensing, to realize imaging protocols, enabling individual nuclei to be located with Angstrom precision. The achieved signal-to-noise ratio under ambient conditions allows single nuclear spin sensitivity to be achieved within seconds. PMID:25146503

  3. Nuclear magnetic resonance spectroscopy with single spin sensitivity.

    PubMed

    Müller, C; Kong, X; Cai, J-M; Melentijević, K; Stacey, A; Markham, M; Twitchen, D; Isoya, J; Pezzagna, S; Meijer, J; Du, J F; Plenio, M B; Naydenov, B; McGuinness, L P; Jelezko, F

    2014-01-01

    Nuclear magnetic resonance spectroscopy and magnetic resonance imaging at the ultimate sensitivity limit of single molecules or single nuclear spins requires fundamentally new detection strategies. The strong coupling regime, when interaction between sensor and sample spins dominates all other interactions, is one such strategy. In this regime, classically forbidden detection of completely unpolarized nuclei is allowed, going beyond statistical fluctuations in magnetization. Here we realize strong coupling between an atomic (nitrogen-vacancy) sensor and sample nuclei to perform nuclear magnetic resonance on four (29)Si spins. We exploit the field gradient created by the diamond atomic sensor, in concert with compressed sensing, to realize imaging protocols, enabling individual nuclei to be located with Angstrom precision. The achieved signal-to-noise ratio under ambient conditions allows single nuclear spin sensitivity to be achieved within seconds. PMID:25146503

  4. Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy Characterize a Rodent Model of Covert Stroke

    NASA Astrophysics Data System (ADS)

    Herrera, Sheryl Lyn

    Covert stroke (CS) comprises lesions in the brain often associated by risk factors such as a diet high in fat, salt, cholesterol and sugar (HFSCS). Developing a rodent model for CS incorporating these characteristics is useful for developing and testing interventions. The purpose of this thesis was to determine if magnetic resonance (MR) can detect brain abnormalities to confirm this model will have the desired anatomical effects. Ex vivo MR showed brain abnormalities for rats with the induced lesions and fed the HFSCS diet. Spectra acquired on the fixed livers had an average percent area under the fat peak relative to the water peak of (20+/-4)% for HFSCS and (2+/-2)% for control. In vivo MR images had significant differences between surgeries to induce the lesions (p=0.04). These results show that applying MR identified abnormalities in the rat model and therefore is important in the development of this CS rodent model.

  5. Towards Single Biomolecule Imaging via Optical Nanoscale Magnetic Resonance Imaging.

    PubMed

    Boretti, Alberto; Rosa, Lorenzo; Castelletto, Stefania

    2015-09-01

    Nuclear magnetic resonance (NMR) spectroscopy is a physical marvel in which electromagnetic radiation is charged and discharged by nuclei in a magnetic field. In conventional NMR, the specific nuclei resonance frequency depends on the strength of the magnetic field and the magnetic properties of the isotope of the atoms. NMR is routinely utilized in clinical tests by converting nuclear spectroscopy in magnetic resonance imaging (MRI) and providing 3D, noninvasive biological imaging. While this technique has revolutionized biomedical science, measuring the magnetic resonance spectrum of single biomolecules is still an intangible aspiration, due to MRI resolution being limited to tens of micrometers. MRI and NMR have, however, recently greatly advanced, with many breakthroughs in nano-NMR and nano-MRI spurred by using spin sensors based on an atomic impurities in diamond. These techniques rely on magnetic dipole-dipole interactions rather than inductive detection. Here, novel nano-MRI methods based on nitrogen vacancy centers in diamond are highlighted, that provide a solution to the imaging of single biomolecules with nanoscale resolution in-vivo and in ambient conditions. PMID:26113221

  6. Comparison of nuclear electric resonance and nuclear magnetic resonance in integer and fractional quantum Hall states

    SciTech Connect

    Tomimatsu, Toru Shirai, Shota; Hashimoto, Katsushi Sato, Ken; Hirayama, Yoshiro

    2015-08-15

    Electric-field-induced nuclear resonance (NER: nuclear electric resonance) involving quantum Hall states (QHSs) was studied at various filling factors by exploiting changes in nuclear spins polarized at quantum Hall breakdown. Distinct from the magnetic dipole interaction in nuclear magnetic resonance, the interaction of the electric-field gradient with the electric quadrupole moment plays the dominant role in the NER mechanism. The magnitude of the NER signal strongly depends on whether electronic states are localized or extended. This indicates that NER is sensitive to the screening capability of the electric field associated with QHSs.

  7. Three-dimensional magnetic recording using ferromagnetic resonance

    NASA Astrophysics Data System (ADS)

    Suto, Hirofumi; Kudo, Kiwamu; Nagasawa, Tazumi; Kanao, Taro; Mizushima, Koichi; Sato, Rie

    2016-07-01

    To meet the ever-increasing demand for data storage, future magnetic recording devices will need to be made three-dimensional by implementing multilayer recording. In this article, we present methods of detecting and manipulating the magnetization direction of a specific layer selectively in a vertically stacked multilayer magnetic system, which enable layer-selective read and write operations in three-dimensional magnetic recording devices. The principle behind the methods is ferromagnetic resonance excitation in a microwave magnetic field. By designing each magnetic recording layer to have a different ferromagnetic resonance frequency, magnetization excitation can be induced individually in each layer by tuning the frequency of an applied microwave magnetic field, and this selective magnetization excitation can be utilized for the layer-selective operations. Regarding media for three-dimensional recording, when layers of a perpendicular magnetic material are vertically stacked, dipolar interaction between multiple recording layers arises and is expected to cause problems, such as degradation of thermal stability and switching field distribution. To solve these problems, we propose the use of an antiferromagnetically coupled structure consisting of hard and soft magnetic layers. Because the stray fields from these two layers cancel each other, antiferromagnetically coupled media can reduce the dipolar interaction.

  8. Magnetic Resonance Imaging Studies of Postpartum Depression: An Overview

    PubMed Central

    Fiorelli, Marco; Aceti, Franca; Marini, Isabella; Giacchetti, Nicoletta; Macci, Enrica; Tinelli, Emanuele; Calistri, Valentina; Meuti, Valentina; Caramia, Francesca; Biondi, Massimo

    2015-01-01

    Postpartum depression is a frequent and disabling condition whose pathophysiology is still unclear. In recent years, the study of the neural correlates of mental disorders has been increasingly approached using magnetic resonance techniques. In this review we synthesize the results from studies on postpartum depression in the context of structural, functional, and spectroscopic magnetic resonance studies of major depression as a whole. Compared to the relative wealth of data available for major depression, magnetic resonance studies of postpartum depression are limited in number and design. A systematic literature search yielded only eleven studies conducted on about one hundred mothers with postpartum depression overall. Brain magnetic resonance findings in postpartum depression appear to replicate those obtained in major depression, with minor deviations that are not sufficient to delineate a distinct neurobiological profile for this condition, due to the small samples used and the lack of direct comparisons with subjects with major depression. However, it seems reasonable to expect that studies conducted in larger populations, and using a larger variety of brain magnetic resonance techniques than has been done so far, might allow for the identification of neuroimaging signatures for postpartum depression. PMID:26347585

  9. Magnetic resonance imaging--first human images in Australia.

    PubMed

    Baddeley, H; Doddrell, D M; Brooks, W M; Field, J; Irving, M; Williams, J E

    1986-10-20

    The use of magnetic resonance imaging, in the demonstration of internal human anatomy and in the diagnosis of disease, has the major advantages that the technique is noninvasive, does not require the use of ionizing radiation and that it can demonstrate neurological and cardiovascular lesions that cannot be diagnosed easily by other imaging methods. Magnetic resonance imaging is derived from the principle that certain atomic nuclei in a strong magnetic field will absorb pulses of radiofrequency energy; when the pulse is finished the nuclei will emit radiowaves at the same frequency. These radiowaves are received by specially designed aerials or coils and the information is collected by a computer which reconstructs an image of internal anatomy in a similar way to that of x-ray computed tomography (CT). By changing the strength of the magnetic fields and the frequency of the radiowave pulses, it is possible to examine different sections within the body. The first magnetic resonance images of humans were obtained in Australia in October 1985 on the research instrument of the Queensland Medical Magnetic Resonance Research Centre, which is based at the Mater Hospital in Brisbane, and is part of the University of Queensland's Department of Radiology. PMID:3020385

  10. On-wafer magnetic resonance of magnetite nanoparticles

    NASA Astrophysics Data System (ADS)

    Little, Charles A. E.; Russek, Stephen E.; Booth, James C.; Kabos, Pavel; Usselman, Robert J.

    2015-11-01

    Magnetic resonance measurements of ferumoxytol and TEMPO were made using an on-wafer transmission line technique with a vector network analyzer, allowing for broadband measurements of small sample volumes (4 nL) and small numbers of spins (1 nmol). On-wafer resonance measurements were compared with standard single-frequency cavity-based electron paramagnetic resonance (EPR) measurements using a new power conservation approach and the results show similar line shape. On-wafer magnetic resonance measurements using integrated microfluidics and microwave technology can significantly reduce the cost and sample volumes required for EPR spectral analysis and allow for integration of EPR with existing lab-on-a-chip processing and characterization techniques for point-of-care medical diagnostic applications.

  11. Current-induced spin torque resonance of a magnetic insulator

    NASA Astrophysics Data System (ADS)

    Schreier, Michael; Chiba, Takahiro; Niedermayr, Arthur; Lotze, Johannes; Huebl, Hans; Geprägs, Stephan; Takahashi, Saburo; Bauer, Gerrit E. W.; Gross, Rudolf; Goennenwein, Sebastian T. B.

    2015-10-01

    We report the observation of current-induced spin torque resonance in yttrium iron garnet/platinum bilayers. An alternating charge current at GHz frequencies in the platinum gives rise to dc spin pumping and spin Hall magnetoresistance rectification voltages, induced by the Oersted fields of the ac current and the spin Hall effect-mediated spin transfer torque. In ultrathin yttrium iron garnet films, we observe spin transfer torque actuated magnetization dynamics which are significantly larger than those generated by the ac Oersted field. Spin transfer torques thus efficiently couple charge currents and magnetization dynamics also in magnetic insulators, enabling charge current-based interfacing of magnetic insulators with microwave devices.

  12. Resonant Landau-Zener transitions in a helical magnetic field

    NASA Astrophysics Data System (ADS)

    Wójcik, P.; Adamowski, J.; Wołoszyn, M.; Spisak, B. J.

    2015-06-01

    Spin-dependent electron transport has been studied in magnetic semiconductor waveguides (nanowires) in the helical magnetic field. We have shown that—apart from the well-known conductance dip located at the magnetic field equal to the helical-field amplitude Bh—the additional conductance dips (with zero conductance) appear at a magnetic field different from Bh. This effect occurring in the non-adiabatic regime is explained as resulting from the resonant Landau-Zener transitions between the spin-split subbands.

  13. Desktop fast-field cycling nuclear magnetic resonance relaxometer.

    PubMed

    Sousa, Duarte Mesquita; Marques, Gil Domingos; Cascais, José Manuel; Sebastião, Pedro José

    2010-07-01

    In this paper a new type of Fast Field Cycling (FFC) Nuclear Magnetic Resonance (NMR) relaxometer with low power consumption (200W) and cycle to cycle field stability better than 10(-4) is described. The new high-permeability magnet was designed to allow for good magnetic field homogeneity and allows for the sample rotation around an axis perpendicular to magnetic field, operating with magnetic fields between 0 and 0.21T. The power supply of the new relaxometer was specially developed in order to have steady state accurate currents and allow for magnetic field switching times less than 3ms. Additional control circuits were developed and included to compensate the Earth magnetic field component parallel to the field axis and to compensate for parasitic currents. The main aspects of the developed circuits together with some calibrating experimental results using the liquid crystal compounds 5CB and 8CB are presented and discussed. PMID:20688489

  14. Anicteric early bile duct carcinoma detection with magnetic resonance cholangiopancreatography.

    PubMed

    Oshikiri, Taro; Morita, Takayuki; Fujita, Miyoshi; Miyasaka, Yuji; Senmaru, Naoto; Yamada, Hidehisa; Kondo, Satoshi; Katoh, Hiroyuki

    2005-01-01

    The poor prognosis of extrahepatic bile duct carcinoma makes early detection and diagnosis essential for positive patient outcomes. We describe 2 cases of jaundice-free early extrahepatic bile duct carcinoma detected by magnetic resonance cholangiopancreatography. Extrahepatic bile duct carcinoma was discovered incidentally in patient 1 by magnetic resonance cholangiopancreatography during evaluation of a gallbladder stone. In patient 2, extrahepatic bile duct carcinoma was found during a routine health maintenance exam. Both patients underwent radical surgical intervention. Both patient 1 and 2 have remained in good health for over one year, 3.5 and one year, respectively, and have not exhibited any signs or symptoms of relapse or cancer recurrence. Based on these cases, it appears that magnetic resonance cholangiopancreatography can play a significant role in the early detection of extrahepatic bile duct carcinoma and improve disease prognosis. PMID:15816438

  15. Renal relevant radiology: renal functional magnetic resonance imaging.

    PubMed

    Ebrahimi, Behzad; Textor, Stephen C; Lerman, Lilach O

    2014-02-01

    Because of its noninvasive nature and provision of quantitative measures of a wide variety of physiologic parameters, functional magnetic resonance imaging (MRI) shows great potential for research and clinical applications. Over the past decade, application of functional MRI extended beyond detection of cerebral activity, and techniques for abdominal functional MRI evolved. Assessment of renal perfusion, glomerular filtration, interstitial diffusion, and parenchymal oxygenation turned this modality into an essential research and potentially diagnostic tool. Variations in many renal physiologic markers can be detected using functional MRI before morphologic changes become evident in anatomic magnetic resonance images. Moreover, the framework of functional MRI opened a window of opportunity to develop novel pathophysiologic markers. This article reviews applications of some well validated functional MRI techniques, including perfusion, diffusion-weighted imaging, and blood oxygen level-dependent MRI, as well as some emerging new techniques such as magnetic resonance elastography, which might evolve into clinically useful tools. PMID:24370767

  16. Magnetic resonance spectroscopy and imaging for the study of fossils.

    PubMed

    Giovannetti, Giulio; Guerrini, Andrea; Salvadori, Piero A

    2016-07-01

    Computed tomography (CT) has long been used for investigating palaeontological specimens, as it is a nondestructive technique which avoids the need to dissolve or ionize the fossil sample. However, magnetic resonance spectroscopy (MRS) and magnetic resonance imaging (MRI) have recently gained ground as analytical tools for examination of palaeontological samples, by nondestructively providing information about the structure and composition of fossils. While MRI techniques are able to reveal the three-dimensional geometry of the trace fossil, MRS can provide information on the chemical composition of the samples. The multidimensional nature of MR (magnetic resonance) signals has potential to provide rich three-dimensional data on the palaeontological specimens and also to help in elucidating paleopathological and paleoecological questions. In this work the verified applications and the emerging uses of MRI and MRS in paleontology are reviewed, with particular attention to fossil spores, fossil plants, ambers, fossil invertebrates, and fossil vertebrate studies. PMID:26979538

  17. Magnetic-resonance pore imaging of nonsymmetric microscopic pore shapes

    NASA Astrophysics Data System (ADS)

    Hertel, Stefan Andreas; Wang, Xindi; Hosking, Peter; Simpson, M. Cather; Hunter, Mark; Galvosas, Petrik

    2015-07-01

    Imaging of the microstructure of porous media such as biological tissue or porous solids is of high interest in health science and technology, engineering and material science. Magnetic resonance pore imaging (MRPI) is a recent technique based on nuclear magnetic resonance (NMR) which allows us to acquire images of the average pore shape in a given sample. Here we provide details on the experimental design, challenges, and requirements of MRPI, including its calibration procedures. Utilizing a laser-machined phantom sample, we present images of microscopic pores with a hemiequilateral triangular shape even in the presence of NMR relaxation effects at the pore walls. We therefore show that MRPI is applicable to porous samples without a priori knowledge about their pore shape and symmetry. Furthermore, we introduce "MRPI mapping," which combines MRPI with conventional magnetic resonance imaging (MRI). This enables one to resolve microscopic pore sizes and shapes spatially, thus expanding the application of MRPI to samples with heterogeneous distributions of pores.

  18. Anatomical, functional and molecular biomarker applications of magnetic resonance neuroimaging

    PubMed Central

    Liu, Christina H

    2015-01-01

    MRI and magnetic resonance spectroscopy (MRS) along with computed tomography and PET are the most common imaging modalities used in the clinics to detect structural abnormalities and pathological conditions in the brain. MRI generates superb image resolution/contrast without radiation exposure that is associated with computed tomography and PET; MRS and spectroscopic imaging technologies allow us to measure changes in brain biochemistry. Increasingly, neurobiologists and MRI scientists are collaborating to solve neuroscience problems across sub-cellular through anatomical levels. To achieve successful cross-disciplinary collaborations, neurobiologists must have sufficient knowledge of magnetic resonance principles and applications in order to effectively communicate with their MRI colleagues. This review provides an overview of magnetic resonance techniques and how they can be used to gain insight into the active brain at the anatomical, functional and molecular levels with the goal of encouraging neurobiologists to include MRI/MRS as a research tool in their endeavors. PMID:25774094

  19. Magnetic Resonance, Functional (fMRI) -- Brain

    MedlinePlus

    ... powerful magnetic field, radio frequency pulses and a computer to produce detailed pictures of organs, soft tissues, ... The images can then be examined on a computer monitor, transmitted electronically, printed or copied to a ...

  20. Magnetic anisotropy of polycrystalline magnetoferritin investigated by SQUID and electron magnetic resonance

    NASA Astrophysics Data System (ADS)

    Moro, F.; de Miguel, R.; Jenkins, M.; Gómez-Moreno, C.; Sells, D.; Tuna, F.; McInnes, E. J. L.; Lostao, A.; Luis, F.; van Slageren, J.

    2014-06-01

    Magnetoferritin molecules with an average inorganic core diameter of 5.7±1.6 nm and polycrystalline internal structure were investigated by a combination of transmission electron microscopy, magnetic susceptibility, magnetization, and electron magnetic resonance (EMR) experiments. The temperature and frequency dependence of the magnetic susceptibility allowed for the determination of the magnetic anisotropy on an experimental time scale which spans from seconds to nanoseconds. In addition, angle-dependent EMR experiments were carried out for the determination of the nanoparticle symmetry and internal magnetic field. Due to the large surface to volume ratio, the nanoparticles show larger and uniaxial rather than cubic magnetic anisotropies compared to bulk maghemite and magnetite.

  1. Travelling wave magnetic resonance imaging at 3 T

    NASA Astrophysics Data System (ADS)

    Vazquez, F.; Martin, R.; Marrufo, O.; Rodriguez, A. O.

    2013-08-01

    Waveguides have been successfully used to generate magnetic resonance images at 7 T with whole-body systems. The bore diameter limits the magnetic resonance signal transmitted because its specific cut-off frequency is greater than the majority of resonant frequencies in magnetic resonance imaging and spectroscopy. This restriction can be overcome by using a parallel-plate waveguide whose cut-off frequency is zero for the transverse electromagnetic modes and it can propagate any frequency. To study the potential benefits of travelling-wave excitation for whole-body imaging at 3 T, we compare numerical simulations of the principal mode propagation for a parallel-plate waveguide filled with a cylindrical phantom and two surface coils for all simulations at 1.5 T, 3 T, 4.7, 7 T, and 9.4 T. The principal mode shows very little variation of the field magnitude along the propagation direction at 3 T when compared to other higher resonant frequencies. Unlike the standard method for travelling-wave magnetic resonance imaging, a parallel-plate waveguide prototype was built and used together with a whole-body birdcage coil for signal transmission and a pair of circular coils for reception. Experimental B1 mapping was computed to investigate the feasibility of this approach and, the point spread function method was used to measure the imager performance. Human leg images were acquired to experimentally validate this approach. The numerical magnetic field and specific absorption rate of a simulated leg were computed and results are within the safety limits. The B1 mapping and point spread function results showed that it is possible to conduct travelling-wave imaging experiments with good imager performance. Human leg images were also obtained with the whole-body birdcage coil for comparison purposes. The simulated and in vivo travelling-wave results of the human leg correspond very well for the signal received. A similar image signal-to-noise ratio was observed for the

  2. Magnetic resonance imaging in entomology: a critical review

    PubMed Central

    Hart, A.G.; Bowtell, R.W.; Köckenberger, W.; Wenseleers, T.; Ratnieks, F.L.W.

    2003-01-01

    Magnetic resonance imaging (MRI) enables in vivo imaging of organisms. The recent development of the magnetic resonance microscope (MRM) has enabled organisms within the size range of many insects to be imaged. Here, we introduce the principles of MRI and MRM and review their use in entomology. We show that MRM has been successfully applied in studies of parasitology, development, metabolism, biomagnetism and morphology, and the advantages and disadvantages relative to other imaging techniques are discussed. In addition, we illustrate the images that can be obtained using MRM. We conclude that although MRM has significant potential, further improvements to the technique are still desirable if it is to become a mainstream imaging technology in entomology. Abbreviation: CSI chemical shift imaging. The dependence of the resonance frequency of a nucleus on the chemical binding of the atom or molecule in which it is contained. (N)MRI (nuclear) magnetic resonance imaging MRM magnetic resonance microscopy Voxel A contraction for volume element, which is the basic unit of MR reconstruction; represented as a pixel in the display of the MR image. PMID:15841222

  3. Computation of flow pressure fields from magnetic resonance velocity mapping.

    PubMed

    Yang, G Z; Kilner, P J; Wood, N B; Underwood, S R; Firmin, D N

    1996-10-01

    Magnetic resonance phase velocity mapping has unrivalled capacities for acquiring in vivo multi-directional blood flow information. In this study, the authors set out to derive both spatial and temporal components of acceleration, and hence differences of pressure in a flow field using cine magnetic resonance velocity data. An efficient numerical algorithm based on the Navier-Stokes equations for incompressible Newtonian fluid was used. The computational approach was validated with in vitro flow phantoms. This work aims to contribute to a better understanding of cardiovascular dynamics and to serve as a basis for investigating pulsatile pressure/flow relationships associated with normal and impaired cardiovascular function. PMID:8892202

  4. Artifacts and pitfalls in shoulder magnetic resonance imaging*

    PubMed Central

    Marcon, Gustavo Felix; Macedo, Tulio Augusto Alves

    2015-01-01

    Magnetic resonance imaging has revolutionized the diagnosis of shoulder lesions, in many cases becoming the method of choice. However, anatomical variations, artifacts and the particularity of the method may be a source of pitfalls, especially for less experienced radiologists. In order to avoid false-positive and false-negative results, the authors carried out a compilation of imaging findings that may simulate injury. It is the authors’ intention to provide a useful, consistent and comprehensive reference for both beginner residents and skilled radiologists who work with musculoskeletal magnetic resonance imaging, allowing for them to develop more precise reports and helping them to avoid making mistakes. PMID:26379323

  5. Cranial and spinal magnetic resonance imaging: A guide and atlas

    SciTech Connect

    Daniels, D.L.; Haughton, V.M.

    1987-01-01

    This atlas provides a clinical guide to interpreting cranial and spinal magnetic resonance images. The book includes coverage of the cerebrum, temporal bone, and cervical, thoracic, and lumbar spine, with more than 400 scan images depicting both normal anatomy and pathologic findings. Introductory chapters review the practical physics of magnetic resonance (MR) imaging, offer guidelines for interpreting cranial MR scans, and provide coverage of each anatomic region of the cranium and spine. For each region, scans accompanied by captions, show normal anatomic sections matched with MR images. These are followed by MR scans depicting various disease states.

  6. Functional magnetic resonance imaging in medicine and physiology

    SciTech Connect

    Moonen, C.T.W.; van Zijl, P.C.M.; Frank, J.A.; Bihan, D.L.; Becker, E.D. )

    1990-10-05

    Magnetic resonance imaging (MRI) is a well-established diagnostic tool that provides detailed information about macroscopic structure and anatomy. Recent advances in MRI allow the noninvasive spatial evaluation of various biophysical and biochemical processes in living systems. Specifically, the motion of water can be measured in processes such as vascular flow, capillary flow, diffusion, and exchange. In addition, the concentrations of various metabolites can be determined for the assessment of regional regulation of metabolism. Examples are given that demonstrate the use of functional MRI for clinical and research purposes. This development adds a new dimension to the application of magnetic resonance to medicine and physiology.

  7. Malformations of cortical development: 3T magnetic resonance imaging features

    PubMed Central

    Battal, Bilal; Ince, Selami; Akgun, Veysel; Kocaoglu, Murat; Ozcan, Emrah; Tasar, Mustafa

    2015-01-01

    Malformation of cortical development (MCD) is a term representing an inhomogeneous group of central nervous system abnormalities, referring particularly to embriyological aspect as a consequence of any of the three developmental stages, i.e., cell proliferation, cell migration and cortical organization. These include cotical dysgenesis, microcephaly, polymicrogyria, schizencephaly, lissencephaly, hemimegalencephaly, heterotopia and focal cortical dysplasia. Since magnetic resonance imaging is the modality of choice that best identifies the structural anomalies of the brain cortex, we aimed to provide a mini review of MCD by using 3T magnetic resonance scanner images. PMID:26516429

  8. Electron Paramagnetic Resonance of Single Magnetic Moment on a Surface.

    PubMed

    Berggren, P; Fransson, J

    2016-01-01

    We address electron spin resonance of single magnetic moments in a tunnel junction using time-dependent electric fields and spin-polarized current. We show that the tunneling current directly depends on the local magnetic moment and that the frequency of the external electric field mixes with the characteristic Larmor frequency of the local spin. The importance of the spin-polarized current induced anisotropy fields acting on the local spin moment is, moreover, demonstrated. Our proposed model thus explains the absence of an electron spin resonance for a half integer spin, in contrast with the strong signal observed for an integer spin. PMID:27156935

  9. Magnetic Resonance Spectroscopy of siRNA-Based Cancer Therapy

    PubMed Central

    Penet, Marie-France; Chen, Zhihang; Mori, Noriko; Krishnamachary, Balaji; Bhujwalla, Zaver M.

    2016-01-01

    Small interfering RNA (siRNA) is routinely used as a biological tool to silence specific genes, and is under active investigation in cancer treatment strategies. Noninvasive magnetic resonance spectroscopy (MRS) provides the ability to assess the functional effects of siRNA-mediated gene silencing in cultured cancer cells, and following nanoparticle-based delivery in tumors in vivo. Here we describe the use of siRNA to downregulate choline kinase, a critical enzyme in choline phospholipid metabolism of cancer cells and tumors, and the use of 1H MRS of cells and 1H magnetic resonance spectroscopic imaging (MRSI) of tumors to assess the efficacy of the downregulation. PMID:26530913

  10. Magnetic resonance imaging as a tool for extravehicular activity analysis

    NASA Technical Reports Server (NTRS)

    Dickenson, R.; Lorenz, C.; Peterson, S.; Strauss, A.; Main, J.

    1992-01-01

    The purpose of this research is to examine the value of magnetic resonance imaging (MRI) as a means of conducting kinematic studies of the hand for the purpose of EVA capability enhancement. After imaging the subject hand using a magnetic resonance scanner, the resulting 2D slices were reconstructed into a 3D model of the proximal phalanx of the left hand. Using the coordinates of several landmark positions, one is then able to decompose the motion of the rigid body. MRI offers highly accurate measurements due to its tomographic nature without the problems associated with other imaging modalities for in vivo studies.

  11. Implementation of NMR pulse sequences for Magnetic Resonance Force Microscopy

    NASA Astrophysics Data System (ADS)

    Moores, Bradley; Eichler, Alexander; Degen, Christian

    2014-03-01

    Magnetic resonance force microscopy (MRFM) is a scanning microscopy technique that allows measuring nuclear spin densities with a resolution of a few nanometers. Ongoing efforts are aiming at improving this resolution, which might ultimately facilitate non-destructive 3D scans of complex molecules or solid state systems with atomic resolution. Here, we review our current efforts to utilize in an MRFM experiment pulsing techniques borrowed from the nuclear magnetic resonance community. The use of advanced pulsing schemes may improve signal-to-noise ratio, imaging resolution, and allow the investigation of novel phenomena.

  12. Electron Paramagnetic Resonance of Single Magnetic Moment on a Surface

    PubMed Central

    Berggren, P.; Fransson, J.

    2016-01-01

    We address electron spin resonance of single magnetic moments in a tunnel junction using time-dependent electric fields and spin-polarized current. We show that the tunneling current directly depends on the local magnetic moment and that the frequency of the external electric field mixes with the characteristic Larmor frequency of the local spin. The importance of the spin-polarized current induced anisotropy fields acting on the local spin moment is, moreover, demonstrated. Our proposed model thus explains the absence of an electron spin resonance for a half integer spin, in contrast with the strong signal observed for an integer spin. PMID:27156935

  13. Magnetic Resonance Imaging: From Spin Physics to Medical Diagnosis

    NASA Astrophysics Data System (ADS)

    Nacher, Pierre-Jean

    Two rather similar historical evolutions are evoked, each one originating in fundamental spin studies by physicists, and ending as magnetic resonance imaging (MRI), a set of invaluable tools for clinical diagnosis in the hands of medical doctors. The first one starts with the early work on nuclear magnetic resonance, the founding stone of the usual proton-based MRI, of which the basic principles are described. The second one starts with the optical pumping developments made to study the effects of spin polarization in various fundamental problems. Its unexpected outcome is a unique imaging modality, also based on MRI, for the study of lung physiology and pathologies.

  14. Algorithmic cooling in liquid-state nuclear magnetic resonance

    NASA Astrophysics Data System (ADS)

    Atia, Yosi; Elias, Yuval; Mor, Tal; Weinstein, Yossi

    2016-01-01

    Algorithmic cooling is a method that employs thermalization to increase qubit purification level; namely, it reduces the qubit system's entropy. We utilized gradient ascent pulse engineering, an optimal control algorithm, to implement algorithmic cooling in liquid-state nuclear magnetic resonance. Various cooling algorithms were applied onto the three qubits of C132-trichloroethylene, cooling the system beyond Shannon's entropy bound in several different ways. In particular, in one experiment a carbon qubit was cooled by a factor of 4.61. This work is a step towards potentially integrating tools of NMR quantum computing into in vivo magnetic-resonance spectroscopy.

  15. Nuclear magnetic resonance in environmental engineering: principles and applications.

    PubMed

    Lens, P N; Hemminga, M A

    1998-01-01

    This paper gives an introduction to nuclear magnetic resonance spectroscopy (NMR) and magnetic resonance imaging (MRI) in relation to applications in the field of environmental science and engineering. The underlying principles of high resolution solution and solid state NMR, relaxation time measurements and imaging are presented. Then, the use of NMR is illustrated and reviewed in studies of biodegradation and biotransformation of soluble and solid organic matter, removal of nutrients and xenobiotics, fate of heavy metal ions, and transport processes in bioreactor systems. PMID:10335581

  16. Development of magnetic resonance technology for noninvasive boron quantification

    SciTech Connect

    Bradshaw, K.M.

    1990-11-01

    Boron magnetic resonance imaging (MRI) and spectroscopy (MRS) were developed in support of the noninvasive boron quantification task of the Idaho National Engineering Laboratory (INEL) Power Burst Facility/Boron Neutron Capture Therapy (PBF/BNCT) program. The hardware and software described in this report are modifications specific to a GE Signa{trademark} MRI system, release 3.X and are necessary for boron magnetic resonance operation. The technology developed in this task has been applied to obtaining animal pharmacokinetic data of boron compounds (drug time response) and the in-vivo localization of boron in animal tissue noninvasively. 9 refs., 21 figs.

  17. Duffing oscillation-induced reversal of magnetic vortex core by a resonant perpendicular magnetic field

    PubMed Central

    Moon, Kyoung-Woong; Chun, Byong Sun; Kim, Wondong; Qiu, Z. Q.; Hwang, Chanyong

    2014-01-01

    Nonlinear dynamics of the magnetic vortex state in a circular nanodisk was studied under a perpendicular alternating magnetic field that excites the radial modes of the magnetic resonance. Here, we show that as the oscillating frequency is swept down from a frequency higher than the eigenfrequency, the amplitude of the radial mode is almost doubled to the amplitude at the fixed resonance frequency. This amplitude has a hysteresis vs. frequency sweeping direction. Our result showed that this phenomenon was due to a Duffing-type nonlinear resonance. Consequently, the amplitude enhancement reduced the vortex core-switching magnetic field to well below 10 mT. A theoretical model corresponding to the Duffing oscillator was developed from the Landau–Lifshitz–Gilbert equation to explore the physical origin of the simulation result. This work provides a new pathway for the switching of the magnetic vortex core polarity in future magnetic storage devices. PMID:25145837

  18. Duffing oscillation-induced reversal of magnetic vortex core by a resonant perpendicular magnetic field.

    PubMed

    Moon, Kyoung-Woong; Chun, Byong Sun; Kim, Wondong; Qiu, Z Q; Hwang, Chanyong

    2014-01-01

    Nonlinear dynamics of the magnetic vortex state in a circular nanodisk was studied under a perpendicular alternating magnetic field that excites the radial modes of the magnetic resonance. Here, we show that as the oscillating frequency is swept down from a frequency higher than the eigenfrequency, the amplitude of the radial mode is almost doubled to the amplitude at the fixed resonance frequency. This amplitude has a hysteresis vs. frequency sweeping direction. Our result showed that this phenomenon was due to a Duffing-type nonlinear resonance. Consequently, the amplitude enhancement reduced the vortex core-switching magnetic field to well below 10 mT. A theoretical model corresponding to the Duffing oscillator was developed from the Landau-Lifshitz-Gilbert equation to explore the physical origin of the simulation result. This work provides a new pathway for the switching of the magnetic vortex core polarity in future magnetic storage devices. PMID:25145837

  19. Multiple-receptor wireless power transfer for magnetic sensors charging on Mars via magnetic resonant coupling

    NASA Astrophysics Data System (ADS)

    Liu, Chunhua; Chau, K. T.; Zhang, Zhen; Qiu, Chun; Lin, Fei; Ching, T. W.

    2015-05-01

    This paper proposes a new idea for magnetic sensors charging on Mars, which aims to effectively transmit energy from Mars Rover to distributed magnetic sensors. The key is to utilize wireless power transfer (WPT) to enable multiple receptors extracting energy from the source via magnetic resonant coupling. Namely, the energy transmitter is located on the Mars Rover, whereas the energy receptor is installed in the magnetic sensor. In order to effectively transfer the power, a resonator is installed between the transmitter and the receptors. Based on the proposed idea, the system topology, operation principle, and simulation results are developed. By performing finite element magnetic field analysis, the output power and efficiency of the proposed WPT system are evaluated. It confirms that the Mars Rover carrying with the energy transmitter is capable of loitering around the resonator, while the magnetic sensors on the receptors can be simultaneously charged according to energy-on-demand.

  20. Magnetic Resonance Reversals in Optically Pumped Alkali-Metal Vapor

    NASA Astrophysics Data System (ADS)

    Gong, Fei; Jau, Yuan-Yu; Happer, William

    2007-06-01

    We report an unusual new phenomenon, peculiar sign reversals of the ground-state magnetic resonances and of the ``zero-dip" resonance (Zeeman resonance at zero field) of optically-pumped, alkali-metal vapors. These anomalies occur when a ``weak" circular polarized D1 laser light is tuned to pump atoms predominantly from the lower ground-state hyperfine multiplet. One can understand the signal reversals in simple, semi-quantitative way with reference to this distribution. uantitative computer simulations are in excellent greement with observations.

  1. Magnetic resonance reversals in optically pumped alkali-metal vapor

    NASA Astrophysics Data System (ADS)

    Gong, F.; Jau, Y.-Y.; Happer, W.

    2007-05-01

    We report an unusual phenomenon, peculiar sign reversals of the ground-state magnetic resonances and of the zero-dip resonance (Zeeman resonance at zero field) of optically pumped, alkali-metal vapors. These anomalies occur when a weak circularly polarized D1 laser light is tuned to pump atoms predominantly from the lower ground-state hyperfine multiplet. One can understand the signal reversals in a simple, semiquantitative way with reference to the spin-temperature distribution. Quantitative computer simulations are in excellent agreement with observations.

  2. Developing hyperpolarized krypton-83 for nuclear magnetic resonance spectroscopy and magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Cleveland, Zackary I.

    This dissertation discusses the production of highly nonequilibrium nuclear spin polarization, referred to as hyperpolarization or hp, in the nuclear spin I = 9/2 noble gas isotope krypton-83 using spin exchange optical pumping (SEOP). This nonequilibrium polarization yields nuclear magnetic resonance (NMR) signals that are enhanced three or more orders of magnitude above those of thermally polarized krypton and enables experiments that would otherwise be impossible. Krypton-83 possesses a nuclear electric quadrupole moment that dominates the longitudinal (T1) relaxation due to coupling of the quadrupole moment to fluctuating electric field gradients generated by distortions to the spherical symmetry of the electronic environment. Relaxation slows polarization buildup and limits the maximum signal intensity but makes krypton-83 a sensitive probe of its environment. The gas-phase krypton-83 longitudinal relaxation rate increases linearly with total gas density due to binary collisions. Density independent relaxation, caused by the formation of krypton-krypton van der Waals molecules and surface adsorption, also contributes to the observed rate. Buffer gases suppress van der Waals molecule mediated relaxation by breaking apart the weakly bound krypton dimers. Surface relaxation is gas composition independent and therefore more difficult to suppress. However, this relaxation mechanism makes hp krypton-83 sensitive to important surface properties including surface-to-volume ratio, surface chemistry, and surface temperature. The presence of surfaces with high krypton adsorption affinities (i.e. hydrophobic surfaces) accelerates the relaxation times and can produce T1 contrast in hp krypton-83 magnetic resonance imaging (MRI). Tobacco smoke deposited on surfaces generates strong T1 contrast allowing the observation of smoke deposition with spatial resolution. Conversely, water adsorption on surfaces significantly lengths the T1 times due competitive surface adsorption

  3. Biomedical Investigations with Laser-Polarized Noble Gas Magnetic Resonance

    NASA Technical Reports Server (NTRS)

    Walsworth, Ronald L.

    2001-01-01

    We are developing laser-polarized noble gas nuclear magnetic resonance (NMR) as a novel biomedical imaging tool for ground-based and eventually space-based application. This emerging multidisciplinary technology enables high-resolution gas-space magnetic resonance imaging (MRI) (e.g., of lung ventilation) as well as studies of tissue perfusion. In addition, laser-polarized noble gases (He-3 and Xe-129) do not require a large magnetic field for sensitive detection, opening the door to practical MRI at very low magnetic fields with an open, lightweight, and low-power device. We are pursuing two specific aims in this research. The first aim is to develop a low-field (< 0.01 T) instrument for noble gas MRI of humans, and the second aim is to develop functional MRI of the lung using laser-polarized Xe-129 and related techniques.

  4. Magnetization transfer using inversion recovery during off-resonance irradiation

    PubMed Central

    Mangia, Silvia; De Martino, Federico; Liimatainen, Timo; Garwood, Michael; Michaeli, Shalom

    2011-01-01

    Estimation of magnetization transfer (MT) parameters in vivo can be compromised by an inability to drive the magnetization to a steady state using allowable levels of radiofrequency (RF) irradiation, due to safety concerns (tissue heating and specific absorption rate (SAR)). Rather than increasing the RF duration or amplitude, here we propose to circumvent the SAR limitation by sampling the formation of the steady state in separate measurements made with the magnetization initially along the −z and +z axis of the laboratory frame, i.e. with or without an on-resonance inversion pulse prior to the off-resonance irradiation. Results from human brain imaging demonstrate that this choice provides a tremendous benefit in the fitting procedure used to estimate MT parameters. The resulting parametric maps are characterized by notably increased tissue specificity as compared to those obtained with the standard MT acquisition in which magnetization is initially along the +z axis only. PMID:21601405

  5. Magnetization transfer using inversion recovery during off-resonance irradiation.

    PubMed

    Mangia, Silvia; De Martino, Federico; Liimatainen, Timo; Garwood, Michael; Michaeli, Shalom

    2011-12-01

    Estimation of magnetization transfer (MT) parameters in vivo can be compromised by an inability to drive the magnetization to a steady state using allowable levels of radiofrequency (RF) irradiation, due to safety concerns (tissue heating and specific absorption rate (SAR)). Rather than increasing the RF duration or amplitude, here we propose to circumvent the SAR limitation by sampling the formation of the steady state in separate measurements made with the magnetization initially along the -z and +z axis of the laboratory frame, i.e. with or without an on-resonance inversion pulse prior to the off-resonance irradiation. Results from human brain imaging demonstrate that this choice provides a tremendous benefit in the fitting procedure used to estimate MT parameters. The resulting parametric maps are characterized by notably increased tissue specificity as compared to those obtained with the standard MT acquisition in which magnetization is initially along the +z axis only. PMID:21601405

  6. A magnetic anti-cancer compound for magnet-guided delivery and magnetic resonance imaging

    PubMed Central

    Eguchi, Haruki; Umemura, Masanari; Kurotani, Reiko; Fukumura, Hidenobu; Sato, Itaru; Kim, Jeong-Hwan; Hoshino, Yujiro; Lee, Jin; Amemiya, Naoyuki; Sato, Motohiko; Hirata, Kunio; Singh, David J.; Masuda, Takatsugu; Yamamoto, Masahiro; Urano, Tsutomu; Yoshida, Keiichiro; Tanigaki, Katsumi; Yamamoto, Masaki; Sato, Mamoru; Inoue, Seiichi; Aoki, Ichio; Ishikawa, Yoshihiro

    2015-01-01

    Research on controlled drug delivery for cancer chemotherapy has focused mainly on ways to deliver existing anti-cancer drug compounds to specified targets, e.g., by conjugating them with magnetic particles or encapsulating them in micelles. Here, we show that an iron-salen, i.e., μ-oxo N,N'- bis(salicylidene)ethylenediamine iron (Fe(Salen)), but not other metal salen derivatives, intrinsically exhibits both magnetic character and anti-cancer activity. X-Ray crystallographic analysis and first principles calculations based on the measured structure support this. It promoted apoptosis of various cancer cell lines, likely, via production of reactive oxygen species. In mouse leg tumor and tail melanoma models, Fe(Salen) delivery with magnet caused a robust decrease in tumor size, and the accumulation of Fe(Salen) was visualized by magnetic resonance imaging. Fe(Salen) is an anti-cancer compound with magnetic property, which is suitable for drug delivery and imaging. We believe such magnetic anti-cancer drugs have the potential to greatly advance cancer chemotherapy for new theranostics and drug-delivery strategies. PMID:25779357

  7. A magnetic anti-cancer compound for magnet-guided delivery and magnetic resonance imaging.

    PubMed

    Eguchi, Haruki; Umemura, Masanari; Kurotani, Reiko; Fukumura, Hidenobu; Sato, Itaru; Kim, Jeong-Hwan; Hoshino, Yujiro; Lee, Jin; Amemiya, Naoyuki; Sato, Motohiko; Hirata, Kunio; Singh, David J; Masuda, Takatsugu; Yamamoto, Masahiro; Urano, Tsutomu; Yoshida, Keiichiro; Tanigaki, Katsumi; Yamamoto, Masaki; Sato, Mamoru; Inoue, Seiichi; Aoki, Ichio; Ishikawa, Yoshihiro

    2015-01-01

    Research on controlled drug delivery for cancer chemotherapy has focused mainly on ways to deliver existing anti-cancer drug compounds to specified targets, e.g., by conjugating them with magnetic particles or encapsulating them in micelles. Here, we show that an iron-salen, i.e., μ-oxo N,N'- bis(salicylidene)ethylenediamine iron (Fe(Salen)), but not other metal salen derivatives, intrinsically exhibits both magnetic character and anti-cancer activity. X-Ray crystallographic analysis and first principles calculations based on the measured structure support this. It promoted apoptosis of various cancer cell lines, likely, via production of reactive oxygen species. In mouse leg tumor and tail melanoma models, Fe(Salen) delivery with magnet caused a robust decrease in tumor size, and the accumulation of Fe(Salen) was visualized by magnetic resonance imaging. Fe(Salen) is an anti-cancer compound with magnetic property, which is suitable for drug delivery and imaging. We believe such magnetic anti-cancer drugs have the potential to greatly advance cancer chemotherapy for new theranostics and drug-delivery strategies. PMID:25779357

  8. A magnetic anti-cancer compound for magnet-guided delivery and magnetic resonance imaging

    NASA Astrophysics Data System (ADS)

    Eguchi, Haruki; Umemura, Masanari; Kurotani, Reiko; Fukumura, Hidenobu; Sato, Itaru; Kim, Jeong-Hwan; Hoshino, Yujiro; Lee, Jin; Amemiya, Naoyuki; Sato, Motohiko; Hirata, Kunio; Singh, David J.; Masuda, Takatsugu; Yamamoto, Masahiro; Urano, Tsutomu; Yoshida, Keiichiro; Tanigaki, Katsumi; Yamamoto, Masaki; Sato, Mamoru; Inoue, Seiichi; Aoki, Ichio; Ishikawa, Yoshihiro

    2015-03-01

    Research on controlled drug delivery for cancer chemotherapy has focused mainly on ways to deliver existing anti-cancer drug compounds to specified targets, e.g., by conjugating them with magnetic particles or encapsulating them in micelles. Here, we show that an iron-salen, i.e., μ-oxo N,N'- bis(salicylidene)ethylenediamine iron (Fe(Salen)), but not other metal salen derivatives, intrinsically exhibits both magnetic character and anti-cancer activity. X-Ray crystallographic analysis and first principles calculations based on the measured structure support this. It promoted apoptosis of various cancer cell lines, likely, via production of reactive oxygen species. In mouse leg tumor and tail melanoma models, Fe(Salen) delivery with magnet caused a robust decrease in tumor size, and the accumulation of Fe(Salen) was visualized by magnetic resonance imaging. Fe(Salen) is an anti-cancer compound with magnetic property, which is suitable for drug delivery and imaging. We believe such magnetic anti-cancer drugs have the potential to greatly advance cancer chemotherapy for new theranostics and drug-delivery strategies.

  9. Probing arrays of circular magnetic microdots by ferromagnetic resonance.

    SciTech Connect

    Kakazei, G. N.; Mewes, T.; Wigen, P. E.; Hammel, P. C.; Slavin, A. N.; Pogorelov, Y. G.; Costa, M. D.; Golub, V. O.; Guslienko, K. Y.; Novosad, V.

    2008-06-01

    X-band ferromagnetic resonance (FMR) was used to characterize in-plane magnetic anisotropies in rectangular and square arrays of circular nickel and Permalloy microdots. In the case of a rectangular lattice, as interdot distances in one direction decrease, the in-plane uniaxial anisotropy field increases, in good agreement with a simple theory of magnetostatically interacting uniformly magnetized dots. In the case of a square lattice a four-fold anisotropy of the in-plane FMR field H(r) was found when the interdot distance a gets comparable to the dot diameter D. This anisotropy, not expected in the case of uniformly magnetized dots, was explained by a non-uniform magnetization m(r) in a dot in response to dipolar forces in the patterned magnetic structure. It is well described by an iterative solution of a continuous variation procedure. In the case of perpendicular magnetization multiple sharp resonance peaks were observed below the main FMR peak in all the samples, and the relative positions of these peaks were independent of the interdot separations. Quantitative description of the observed multiresonance FMR spectra was given using the dipole-exchange spin wave dispersion equation for a perpendicularly magnetized film where in-plane wave vector is quantized due to the finite dot radius, and the inhomogenetiy of the intradot static demagnetization field in the nonellipsoidal dot is taken into account. It was demonstrated that ferromagnetic resonance force microscopy (FMRFM) can be used to determine both local and global properties of patterned submicron ferromagnetic samples. Local spectroscopy together with the possibility to vary the tip-sample spacing enables the separation of those two contributions to a FMRFM spectrum. The global FMR properties of circular submicron dots determined using magnetic resonance force microscopy are in a good agreement with results obtained using conventional FMR and with theoretical descriptions.

  10. Enhancing Eu(3+) magnetic dipole emission by resonant plasmonic nanostructures.

    PubMed

    Hussain, Rabia; Kruk, Sergey S; Bonner, Carl E; Noginov, Mikhail A; Staude, Isabelle; Kivshar, Yuri S; Noginova, Natalia; Neshev, Dragomir N

    2015-04-15

    We demonstrate the enhancement of magnetic dipole spontaneous emission from Eu3+ ions by an engineered plasmonic nanostructure that controls the electromagnetic environment of the emitter. Using an optical microscope setup, an enhancement in the intensity of the Eu3+ magnetic dipole emission was observed for emitters located in close vicinity to a gold nanohole array designed to support plasmonic resonances overlapping with the emission spectrum of the ions. PMID:25872041

  11. Interaction between magnetic agglomerates and an extended free radicals network studied by magnetic resonance

    NASA Astrophysics Data System (ADS)

    Guskos, Niko; Zolnierkiewicz, Grzegorz; Typek, Janusz; Guskos, Aleksander; Berczynski, Pawel; Petridis, Dimitri

    2012-02-01

    Solids containing an extended network of free radicals have been prepared and studied by magnetic resonance techniques in the 4-290 K temperature range. One solid contained additionally a small amount of magnetic γ-Fe2O3 in the form of nanoparticle agglomerates. The solid without agglomerates displayed only a narrow, single resonance line centered at g eff = 2.0043. The magnetic resonance measurements of the solid with γ-Fe2O3 agglomerates gave a spectrum composed of two lines attributed to two different magnetic centers: a narrow line due to free radicals and a broad line arising from magnetic iron oxide agglomerates. In the high temperature range the integrated intensities of both lines decreased with decreasing temperature. The resonance field of the broad line shifted to lower magnetic fields upon lowering the temperature with the gradient ΔH r/ΔT = 2.3 G/K, while the narrow line shifted towards higher magnetic fields. The linewidth of the broader line increased with decreasing temperature while for the narrow lines in both samples this change was small. The magnetic iron oxide clusters produce a magnetic field which acts on the free radicals network and its strength depends essentially on the concentration of clusters. The reorientation process in the free radicals network is more intense in the sample without magnetic clusters.

  12. Interaction between magnetic agglomerates and an extended free radicals network studied by magnetic resonance

    NASA Astrophysics Data System (ADS)

    Guskos, Niko; Zolnierkiewicz, Grzegorz; Typek, Janusz; Guskos, Aleksander; Berczynski, Pawel; Petridis, Dimitri

    2012-02-01

    Solids containing an extended network of free radicals have been prepared and studied by magnetic resonance techniques in the 4-290 K temperature range. One solid contained additionally a small amount of magnetic γ-Fe2O3 in the form of nanoparticle agglomerates. The solid without agglomerates displayed only a narrow, single resonance line centered at g eff = 2.0043. The magnetic resonance measurements of the solid with γ-Fe2O3 agglomerates gave a spectrum composed of two lines attributed to two different magnetic centers: a narrow line due to free radicals and a broad line arising from magnetic iron oxide agglomerates. In the high temperature range the integrated intensities of both lines decreased with decreasing temperature. The resonance field of the broad line shifted to lower magnetic fields upon lowering the temperature with the gradient Δ H r /Δ T = 2.3 G/K, while the narrow line shifted towards higher magnetic fields. The linewidth of the broader line increased with decreasing temperature while for the narrow lines in both samples this change was small. The magnetic iron oxide clusters produce a magnetic field which acts on the free radicals network and its strength depends essentially on the concentration of clusters. The reorientation process in the free radicals network is more intense in the sample without magnetic clusters.

  13. Magnetic resonance imaging without field cycling at less than earth's magnetic field

    NASA Astrophysics Data System (ADS)

    Lee, Seong-Joo; Shim, Jeong Hyun; Kim, Kiwoong; Yu, Kwon Kyu; Hwang, Seong-min

    2015-03-01

    A strong pre-polarization field, usually tenths of a milli-tesla in magnitude, is used to increase the signal-to-noise ratio in ordinary superconducting quantum interference device-based nuclear magnetic resonance/magnetic resonance imaging experiments. Here, we introduce an experimental approach using two techniques to remove the need for the pre-polarization field. A dynamic nuclear polarization (DNP) technique enables us to measure an enhanced resonance signal. In combination with a π / 2 pulse to avoid the Bloch-Siegert effect in a micro-tesla field, we obtained an enhanced magnetic resonance image by using DNP technique with a 34.5 μT static external magnetic field without field cycling. In this approach, the problems of eddy current and flux trapping in the superconducting pickup coil, both due to the strong pre-polarization field, become negligible.

  14. Magnetic resonance imaging without field cycling at less than earth's magnetic field

    SciTech Connect

    Lee, Seong-Joo Shim, Jeong Hyun; Kim, Kiwoong; Yu, Kwon Kyu; Hwang, Seong-min

    2015-03-09

    A strong pre-polarization field, usually tenths of a milli-tesla in magnitude, is used to increase the signal-to-noise ratio in ordinary superconducting quantum interference device-based nuclear magnetic resonance/magnetic resonance imaging experiments. Here, we introduce an experimental approach using two techniques to remove the need for the pre-polarization field. A dynamic nuclear polarization (DNP) technique enables us to measure an enhanced resonance signal. In combination with a π/2 pulse to avoid the Bloch-Siegert effect in a micro-tesla field, we obtained an enhanced magnetic resonance image by using DNP technique with a 34.5 μT static external magnetic field without field cycling. In this approach, the problems of eddy current and flux trapping in the superconducting pickup coil, both due to the strong pre-polarization field, become negligible.

  15. Calculation of ferromagnetic resonance spectra for chains of magnetic particles

    NASA Astrophysics Data System (ADS)

    Newell, A. J.

    2010-12-01

    Magnetotactic bacteria are a taxonomically diverse group of bacteria that have chains of ferromagnetic crystals inside. These bacteria mostly live in the oxic-anoxic interface (OAI) of aquatic environments. The magnetic chains orient the bacteria parallel to the Earth's magnetic field and help them to maintain their position near the OAI. These chains show the fingerprint of natural selection acting to optimize the magnetic moment per unit iron. This is achieved in a number of ways: the alignment in chains, a narrow size range, crystallographic perfection and chemical purity. Because of these distinctive characteristics, the particles can still be identified after the bacteria have died. Such magnetofossils are useful both as records of bacterial evolution and environmental markers. They can most reliably be identified by microscopy, but that is very labor-intensive. A number of magnetic measurements have been developed to identify magnetofossils quickly and non-invasively. However, the only test that can specifically identify the chain structure is ferromagnetic resonance (FMR), which measures the response to a magnetic field oscillating at microwave frequencies. Although the experimental side of ferromagnetic resonance is well developed, the theoretical models for interpreting them have been limited. A new method is presented for calculating resonance frequencies as well as complete power spectra for chains of interacting magnetic particles. Spectra are calculated and compared with data for magnetotactic bacteria.

  16. Nuclear magnetic resonance study of potassium dihydrophosphate

    NASA Astrophysics Data System (ADS)

    Uskova, N. I.; Podorozhkin, D. Yu.; Charnaya, E. V.; Nefedov, D. Yu.; Baryshnikov, S. V.; Bugaev, A. S.; Lee, M. K.; Chang, L. J.

    2016-04-01

    A powder sample of potassium dihydrophosphate KH2PO4 has been studied by the 31P NMR method in a wide temperature range covering the ferroelectric phase transition. Changes in the position and shape of the resonance line at the transition to the ferroelectric phase have been revealed. The parameters of the chemical shift tensor of 31P (isotropic shift, anisotropy, and asymmetry) in the ferroelectric phase have been calculated from the experimental data. A sharp increase in the anisotropy of the tensor at the phase transition has been demonstrated. Dielectric measurements have also been carried out to verify the transition temperature.

  17. Magnetic Resonance Perfusion Imaging in the Study of Language

    ERIC Educational Resources Information Center

    Hillis, Argye E.

    2007-01-01

    This paper provides a brief review of various uses of magnetic resonance perfusion imaging in the investigation of brain/language relationships. The reviewed studies illustrate how perfusion imaging can reveal areas of brain where dysfunction due to low blood flow is associated with specific language deficits, and where restoration of blood flow…

  18. Principles of functional magnetic resonance imaging: application to auditory neuroscience.

    PubMed

    Cacace, A T; Tasciyan, T; Cousins, J P

    2000-05-01

    Functional imaging based on magnetic resonance methods is a new research frontier for exploring a wide range of central nervous system (CNS) functions, including information processing in sensory, motor, cognitive, and linguistic systems. Being able to localize and study human brain function in vivo, in relatively high resolution and in a noninvasive manner, makes this a technique of unparalleled importance. In order to appreciate and fully understand this area of investigation, a tutorial covering basic aspects of this methodology is presented. We introduce functional magnetic resonance imaging (fMRI) by providing an overview of the studies of different sensory systems in response to modality-specific stimuli, followed by an outline of other areas that have potential clinical relevance to the medical, cognitive, and communicative sciences. The discussion then focuses on the basic principles of magnetic resonance methods including magnetic resonance imaging, MR spectroscopy, fMRI, and the potential role that MR technology may play in understanding a wide range of auditory functions within the CNS, including tinnitus-related activity. Because the content of the material found herein might be unfamiliar to some, we provide a broad range of background and review articles to serve as a technical resource. PMID:10821504

  19. Magnetic resonance imaging in obstructive Müllerian anomalies.

    PubMed

    Sen, Kamal Kumar; Balasubramaniam, Dhivya; Kanagaraj, Vikrant

    2013-04-01

    Herlyn-Werner-Wunderlich (HWW) syndrome is a very rare congenital anomaly of the urogenital tract involving Müllerian ducts and Wolffian structures. It is characterized by the triad of didelphys uterus, obstructed hemivagina, and ipsilateral renal agenesis. Magnetic resonance imaging (MRI) is a sensitive, non-invasive diagnostic modality for demonstrating anatomic variation and associated complications. PMID:24082660

  20. Concepts in Biochemistry: Nuclear Magnetic Resonance Spectroscopy in Biochemistry.

    ERIC Educational Resources Information Center

    Cheatham, Steve

    1989-01-01

    Discusses the nature of a nuclear magnetic resonance (NMR) experiment, the techniques used, the types of structural and dynamic information obtained, and how one can view and refine structures using computer graphics techniques in combination with NMR data. Provides several spectra and a computer graphics image from B-form DNA. (MVL)