Science.gov

Sample records for 133xe clearance curve

  1. Prospective use of xenon /sup 133/Xe clearance for amputation level selection

    SciTech Connect

    Moore, W.S.; Henry, R.E.; Malone, J.M.; Daly, M.J.; Patton, D.; Childers, S.J.

    1981-01-01

    Xenon /sup 133/Xe clearance was used to select the most distal amputation level that would allow sufficient blood flow for healing. Capillary blood flow was first measured at the most distal potential amputation level, then at successive proximal levels until an amputation site was found that had a capillary skin blood flow rate greater than or equal to 2.6 mL/min/100 g of tissue. Xenon /sup 133/Xe in saline was injected intracutaneously at each level, and flow rates were determined using a gamma camera interfaced with a computer system programmed for the Ketty-Schmidt formula modified for capillary blood flow. There were 45 cases, including one toes, six transmetatarsal, five Syme's, 25 below-knee, four knee disarticulation, three above-knee, and one hip disarticulation amputation. All amputations in patients with flow rates exceeding 2.4 mL/min/100 g of tissue healed, with two exceptions.

  2. Penile xenon (/sup 133/Xe) washout: a rapid method of screening for vasculogenic impotence

    SciTech Connect

    Nseyo, U.O.; Wilbur, H.J.; Kang, S.A.; Flesh, L.; Bennett, A.H.

    1984-01-01

    The radioactive inert gas xenon (/sup 133/Xe) is a well-established isotopic indicator used to assess vascular status in many organ systems. Xenon-133 was used to evaluate male impotence. Xenon-133 was injected subcutaneously at the level of the coronal sulcus in the detumescent state. Using the gamma camera, sequential images were obtained and computer-generated curves calculated. The clearance time for 50 per cent washout of the injected /sup 133/Xe (T1/2) was then calculated for each patient, as well as a control group. Preliminary findings indicate a correlation with such established techniques of evaluating erectile impotence as history, physical examination, penile pulse Doppler tracings, and brachial-penile blood pressure index. The xenon-133 washout study was a rapid, minimally invasive, reproducible, and cost-effective method of screening those impotent patients for vasculogenic etiology of their erectile impotence. We recommend the addition of this method to the surgeon engaged in the care of impotent males.

  3. Evaluation of 133Xe and 133Xe(m) decay data.

    PubMed

    Galán, M

    2009-01-01

    This paper presents the decay data evaluation of (133)Xe and (133)Xe(m), which includes the most recent available data, such as half-life results and gamma-ray intensities that have not been considered in previous evaluations. The adopted internal conversion coefficients (ICC) have been calculated using the 'Frozen Orbital' approximation and are compared here to recent measured values. Recent Q-value tabulations, recommended gamma-ray energies for calibrations, as well as new evaluated gamma-ray intensities for the 81- and 233-keV lines (37.0 (3)% and 10.16 (13)%, respectively) are also presented in this evaluation. Atomic radiation emission probabilities (X-ray and Auger electron) associated with nuclear radiations have been deduced and also included in this work. PMID:18805017

  4. Intraoperative sup 133 Xe cerebral blood flow measurements by intravenous versus intracarotid methods

    SciTech Connect

    Young, W.L.; Prohovnik, I.; Schroeder, T.; Correll, J.W.; Ostapkovich, N. )

    1990-10-01

    To document the comparability of cerebral blood flow (CBF) values determined by quantification of 133Xe washout after either intravenous or intracarotid administration, 12 patients undergoing elective carotid endarterectomy anesthetized with N2O/O2 and either isoflurane or halothane were studied. Scintillation counters were placed over the middle cerebral artery territory ipsilateral to the operated carotid artery. CBF was measured by the intravenous method during dissection of the carotid sheath and was calculated as the initial slope index from head washout curves collected for 11 min after injection of 10-20 mCi 133Xe in saline into a large vein. Immediately prior to carotid occlusion, CBF was determined by direct injection of 1 mCi 133Xe in saline into either the internal carotid artery or the common carotid artery with the external carotid artery occluded. For the intracarotid injections, the initial slope was calculated from the 1st min of washout. Data were analyzed by linear regression and analysis of variance. Values are expressed as mean +/- SD. The mean CBF for intravenous and intracarotid methods were both 29 +/- 10 ml.100 g-1.min-1. The correlation between CBF measured by intravenous and intracarotid methods was excellent and was described by the line y = x + 0.6, r = 0.92. We conclude that in the flow range studied, the intravenous technique may be applied to measure CBF in physiologically stable situations in which direct intracarotid injection is not feasible.

  5. Dose dependence of the production yield of endohedral 133Xe-fullerene by ion implantation

    NASA Astrophysics Data System (ADS)

    Watanabe, S.; Ishioka, N. S.; Shimomura, H.; Muramatsu, H.; Sekine, T.

    2003-05-01

    The production yield of endohedral 133Xe-fullerene by ion implantation has been studied by taking advantage of the radioactivity of 133Xe. Fullerene targets, which were produced by vacuum evaporation of C 60 or C 70 on a Ni backing, were bombarded with 30-38 keV 133Xe ions by using an isotope separator at doses ranging from 1 × 10 12 to 1 × 10 14 cm -2. The production yield of endohedral 133Xe-fullerene was determined by an high performance liquid chromatography analysis following the dissolution of the targets in o-dichlorobenzene. It was found that the production yield decreased with increasing dose and incident energy, and the production yield of 133Xe@C 70 was higher than that of 133Xe@C 60 for the same dose and incident energy. Those production yields are discussed in connection with amorphization of fullerene molecules in collisions with 133Xe ions.

  6. Response of Panasonic dosimeters to submersion exposure by 133Xe.

    PubMed

    Hoffman, J M; Catchen, G L

    1990-01-01

    The dose response to 133Xe radiation of several types of Panasonic 800 series thermoluminescent dosimeters (TLD) were evaluated. The dosimeters were exposed by submersion in 133Xe gas. The relative sensitivities of the lithium borate and the calcium sulfate phosphors were determined for several configurations. The TLDs were exposed in the holders (as the devices came from the vendor) with various shields covering the elements, and they were exposed with the TLDs removed from the holders. Some dosimeters were exposed, both in holders and out of holders (TL insert only configuration), both in plastic bags and free in air. For the in-holder configuration, the responses of the heavily shielded (greater than 170 mg cm-2) elements were used to obtain the photon dose-rate component, and the responses of the lightly shielded (less than 13 mg cm-2) element were used to obtain the beta component. Similarly, for the insert-only configurations, the observed over-response of the calcium sulfate phosphors to low-energy photons could be used to separate the beta dose rate component. By using the calculated beta doses, correction factors were determined for the apparent under-responses of the elements to beta radiation. The results of both methods are consistent. These results also suggest that the beta component could be used in environmental monitoring as a more sensitive means to determine 133Xe activities in clouds and to separate some of the effects of submersion exposure from those of distant exposure.

  7. Evaluation of 133Xe radiation exposure dosimetry for workers in nuclear medicine laboratories.

    PubMed

    Piltingsrud, H V; Gels, G L

    1982-06-01

    Evaluation of past studies of 133Xe dosimetry and nuclear medicine laboratory air concentrations of 133Xe indicates that significant levels of 133Xe may exist in routine operational environments of a nuclear medicine laboratory. This leads to the question of whether present health physics radiation control methods are adequate to keep occupational personnel exposures within acceptable levels. It would appear that if personnel dosimeters (film and TLD badges) respond properly to the radiation of 133Xe, normal health physics control procedures are probably adequate. If they do not respond adequately, personnel exposures may exceed recommended levels and special instrumentation or administrative procedures are called for. Therefore, the first step in studying potential problems in the subject area is to evaluate the response of a variety of personnel radiation dosimeters to 133Xe. This paper describes the methods and materials used to expose personnel dosimeters to known amounts of 133Xe radiations in an exposure chamber constructed at the BRH Nuclear Medicine Laboratory. Also presented are calculated values for Dose Equivalents (D.E.) in a phantom from external radiation resulting from immersion in clouds having a constant concentration of 133Xe but varying cloud radii. This implies the relative importance of the beta and the X + gamma radiation responses of the personnel dosimeters under various exposure conditions. Results of this study indicate that none of the dosimeter systems evaluated provide adequate performance for use as a primary indicator of the D.E. resulting from 133Xe radiations for a worker in a nuclear medicine laboratory, and that personnel dosimetry considerations in 133Xe-containing atmospheres are very dependent on the radii of the 133Xe clouds.

  8. Cerebral blood flow studied by /sup 133/Xe inhalation technique in parkinsonism: loss of hyperfrontal pattern

    SciTech Connect

    Bes, A.; Gueell, A.; Fabre, N.; Dupui, P.; Victor, G.; Geraud, G.

    1983-03-01

    Cerebral blood flow (grey matter flow) in parkinsonism requires further investigation. The noninvasive method of /sup 133/Xe inhalation permits study of larger numbers of subjects than previously used invasive techniques such as the intracarotid /sup 133/Xe injection method. Measurements were made in this laboratory in 30 subjects having Parkinson's disease. Mean hemispheric blood flow (F1) values were 70.4 +/- 9.3 ml/100 g/min, compared to 76.3 for a group of age-matched normal subjects, which is a decrease of -7.8%. The most striking difference was the loss of the hyperfrontal distribution in parkinsonism. The prefrontal F1 values were only 1.8% greater than the hemisphere grey matter flow, compared with 8.5% in controls of a similar age group.

  9. Studies on 133Xe wash-out from human skin: quantitative measurements of blood flow in normal and corticosteroid-treated skin.

    PubMed

    Kristensen, J K; Wadskov, S

    1977-04-01

    Blood flow was measured by the 133Xe technique in normal and corticosteroid-treated skin. Epicutaneous and intracutaneous methods of tracer application were compared in normal skin. The two labeling methods were equally suitable for measuring cutaneous blood flow provided calculations in both cases were based on a biexponential resolution of the wash-out curve in its cutaneous and subcutaneous components and provided the traumatic hyperemia phase was considered, when intracutaneous application of the tracer was used. Results were invalidated if calculations were based on initial slope of the wash-out curves.Topical application of beta-methasone valerate in a reduction in cutaneous blood flow as measured by the intracutaneous technique with curve resolution, whereas no effect could be demonstrated when calculations were based on the initial slopes of the curves. The 133Xe technique is a simple and reliable method for measuring cutaneous blood flow, which might prove useful in estimations of penetration ability and potency of topical corticosteroids.

  10. Detection of (133)Xe from the Fukushima nuclear power plant in the upper troposphere above Germany.

    PubMed

    Simgen, Hardy; Arnold, Frank; Aufmhoff, Heinfried; Baumann, Robert; Kaether, Florian; Lindemann, Sebastian; Rauch, Ludwig; Schlager, Hans; Schlosser, Clemens; Schumann, Ulrich

    2014-06-01

    After the accident in the Japanese Fukushima Dai-ichi nuclear power plant in March 2011 large amounts of radioactivity were released and distributed in the atmosphere. Among them were also radioactive noble gas isotopes which can be used as tracers to test global atmospheric circulation models. This work presents unique measurements of the radionuclide (133)Xe from Fukushima in the upper troposphere above Germany. The measurements involve air sampling in a research jet aircraft followed by chromatographic xenon extraction and ultra-low background gas counting with miniaturized proportional counters. With this technique a detection limit of the order of 100 (133)Xe atoms in liter-scale air samples (corresponding to about 100 mBq/m(3)) is achievable. Our results provide proof that the (133)Xe-rich ground level air layer from Fukushima was lifted up to the tropopause and distributed hemispherically. Moreover, comparisons with ground level air measurements indicate that the arrival of the radioactive plume at high altitude over Germany occurred several days before the ground level plume. PMID:24607612

  11. Detection of (133)Xe from the Fukushima nuclear power plant in the upper troposphere above Germany.

    PubMed

    Simgen, Hardy; Arnold, Frank; Aufmhoff, Heinfried; Baumann, Robert; Kaether, Florian; Lindemann, Sebastian; Rauch, Ludwig; Schlager, Hans; Schlosser, Clemens; Schumann, Ulrich

    2014-06-01

    After the accident in the Japanese Fukushima Dai-ichi nuclear power plant in March 2011 large amounts of radioactivity were released and distributed in the atmosphere. Among them were also radioactive noble gas isotopes which can be used as tracers to test global atmospheric circulation models. This work presents unique measurements of the radionuclide (133)Xe from Fukushima in the upper troposphere above Germany. The measurements involve air sampling in a research jet aircraft followed by chromatographic xenon extraction and ultra-low background gas counting with miniaturized proportional counters. With this technique a detection limit of the order of 100 (133)Xe atoms in liter-scale air samples (corresponding to about 100 mBq/m(3)) is achievable. Our results provide proof that the (133)Xe-rich ground level air layer from Fukushima was lifted up to the tropopause and distributed hemispherically. Moreover, comparisons with ground level air measurements indicate that the arrival of the radioactive plume at high altitude over Germany occurred several days before the ground level plume.

  12. Response of Panasonic dosimeters to submersion exposure by sup 133 Xe

    SciTech Connect

    Hoffman, J.M.; Catchen, G.L. )

    1990-01-01

    The dose response to {sup 133}Xe radiation of several types of Panasonic 800 series thermoluminescent dosimeters (TLD) were evaluated. The dosimeters were exposed by submersion in {sup 133}Xe gas. The relative sensitivities of the lithium borate and the calcium sulfate phosphors were determined for several configurations. The TLDs were exposed in the holders (as the devices came from the vendor) with various shields covering the elements, and they were exposed with the TLDs removed from the holders. Some dosimeters were exposed, both in holders and out of holders (TL insert only configuration), both in plastic bags and free in air. For the in-holder configuration, the responses of the heavily shielded (greater than 170 mg cm-2) elements were used to obtain the photon dose-rate component, and the responses of the lightly shielded (less than 13 mg cm-2) element were used to obtain the beta component. Similarly, for the insert-only configurations, the observed over-response of the calcium sulfate phosphors to low-energy photons could be used to separate the beta dose rate component. By using the calculated beta doses, correction factors were determined for the apparent under-responses of the elements to beta radiation. The results of both methods are consistent. These results also suggest that the beta component could be used in environmental monitoring as a more sensitive means to determine {sup 133}Xe activities in clouds and to separate some of the effects of submersion exposure from those of distant exposure.

  13. Relationship of 133Xe cerebral blood flow to middle cerebral arterial flow velocity in men at rest

    NASA Technical Reports Server (NTRS)

    Clark, J. M.; Skolnick, B. E.; Gelfand, R.; Farber, R. E.; Stierheim, M.; Stevens, W. C.; Beck, G. Jr; Lambertsen, C. J.

    1996-01-01

    Cerebral blood flow (CBF) was measured by 133Xe clearance simultaneously with the velocity of blood flow through the left middle cerebral artery (MCA) over a wide range of arterial PCO2 in eight normal men. Average arterial PCO2, which was varied by giving 4% and 6% CO2 in O2 and by controlled hyperventilation on O2, ranged from 25.3 to 49.9 mm Hg. Corresponding average values of global CBF15 were 27.2 and 65.0 ml 100 g min-1, respectively, whereas MCA blood-flow velocity ranged from 42.8 to 94.2 cm/s. The relationship of CBF to MCA blood-flow velocity over the imposed range of arterial PCO2 was described analytically by a parabola with the equation: CBF = 22.8 - 0.17 x velocity + 0.006 x velocity2 The observed data indicate that MCA blood-flow velocity is a useful index of CBF response to change in arterial PCO2 during O2 breathing at rest. With respect to baseline values measured while breathing 100% O2 spontaneously, percent changes in velocity were significantly smaller than corresponding percent changes in CBF at increased levels of arterial PCO2 and larger than CBF changes at the lower arterial PCO2. These observed relative changes are consistent with MCA vasodilation at the site of measurement during exposure to progressive hypercapnia and also during extreme hyperventilation hypocapnia.

  14. Measured absorbed dose rates from semi-infinite hemispherical volumes of 133Xe.

    PubMed

    Munyon, W J; Barber, D E; Howley, J R

    1986-07-01

    Surface absorbed dose rates from different hemispheric volumes of 133Xe have been measured directly with an extrapolation chamber. The results indicate that a linear relationship exists between the radius of the cloud volume and the surface absorbed dose rate for radii between 0 and 23 cm. If cloud volumes with radii larger than 23 cm are taken to be infinite with respect to the range of the charged particles emitted, the absorbed dose rate calculated based on that assumption will be within the uncertainty of any measurement of absorbed dose rate that might be made. For hemispheric volumes having radii less than or equal to 23 cm, the surface absorbed dose rate in tissue-equivalent material, in mGy h-1, is approximated (+/- 20%) by the product of [1.30 mGy h-1 cm-1 kBq-1 cm3] X [cloud radius, cm] X [cloud activity concentration, kBq cm-3].

  15. Atmospheric transport modelling of time resolved 133Xe emissions from the isotope production facility ANSTO, Australia.

    PubMed

    Schöppner, M; Plastino, W; Hermanspahn, N; Hoffmann, E; Kalinowski, M; Orr, B; Tinker, R

    2013-12-01

    The verification of the Comprehensive Nuclear-Test Ban Treaty (CTBT) relies amongst other things on the continuous and worldwide monitoring of radioxenon. The characterization of the existing and legitimate background, which is produced mainly by nuclear power plants and isotope production facilities, is of high interest to improve the capabilities of the monitoring network. However, the emissions from legitimate sources can usually only be estimated. For this paper historic source terms of (133)Xe emissions from the isotope production facility at ANSTO, Sydney, Australia, have been made available in a daily resolution. Based on these high resolution data, different source term sets with weekly, monthly and yearly time resolution have been compiled. These different sets are then applied together with atmospheric transport modelling (ATM) to predict the concentration time series at two radioxenon monitoring stations. The results are compared with each other in order to examine the improvement of the prediction capability depending on the used time resolution of the most dominant source term in the region.

  16. A semiconductor silicon PIN diode matrix detector for measurement of 133Xe washout in small regional skin areas.

    PubMed

    Jensen, J H; Sørensen, J L; Hauge, E N; Sejrsen, P; Bojsen, J

    1993-05-01

    Local variations in microvascularization are expected in lesions and lesion-free skin of patients with pressure sores. To investigate these variations, methods for studies of the regional blood flow rate within small skin areas are needed. Regional blood flow can be estimated by measuring the washout of 133Xe from the tissue. This study describes a 2 x 12 Si PIN diode matrix detector capable of 133Xe detection, and equipped with a collimator to improve the spatial resolution. Thus the regional blood flow in subcutaneous skin areas down to about 2 cm2 can be investigated when the atraumatic epicutaneous labelling technique is used. The capability of the matrix detector and its collimator is described by laboratory investigations. In pilot investigations three normal subjects and three paraplegics with pressure sores were studied. In each individual study the detector matrix was divided into six square areas containing four diode detectors each. Thus six 133Xe disappearance rate constants from adjacent subcutaneous tissue could be determined simultaneously. PMID:8334415

  17. Cerebral hemodynamics in normal-pressure hydrocephalus. Evaluation by 133Xe inhalation method and dynamic CT study

    SciTech Connect

    Tamaki, N.; Kusunoki, T.; Wakabayashi, T.; Matsumoto, S.

    1984-09-01

    Cerebral hemodynamics in 31 patients with suspected normal-pressure hydrocephalus were studied by means of the xenon-133 (133Xe) inhalation method and on dynamic computerized tomography (CT) scanning. Cerebral blood flow (CBF) is reduced in all patients with dementia. Hypoperfusion was noted in a frontal distribution in these patients compared with normal individuals. There was no difference in CBF patterns between patients with good and those with poor outcome. The CBF was increased following cerebrospinal fluid (CSF) shunting in patients who responded to that procedure: increase in flow correlated with clinical improvement, frontal and temporal lobe CBF was most markedly increased, and the CBF pattern became normal. In contrast, CBF was decreased after shunt placement in patients who were considered to have suffered from degenerative dementia, as evidenced by non-response to shunting. Dynamic computerized tomography studies demonstrated that patients with a good outcome showed a postoperative reduction in mean transit time of contrast material, most prominent in the frontal and temporal gray matter, and slight in the deep frontal structures, but not in the major cerebral vessels. Patients with poor outcome after shunting, however, had an increase in transit time in all regions. This corresponded well with the results as determined by the 133Xe inhalation method.

  18. Cerebral blood flow in the newborn infant: comparison of Doppler ultrasound and /sup 133/xenon clearance

    SciTech Connect

    Greisen, G.; Johansen, K.; Ellison, P.H.; Fredriksen, P.S.; Mali, J.; Friis-Hansen, B.

    1984-03-01

    Two techniques of Doppler ultrasound examination, continuous-wave and range-gated, applied to the anterior cerebral artery and to the internal carotid artery, were compared with /sup 133/xenon clearance after intravenous injection. Thirty-two sets of measurements were obtained in 16 newborn infants. The pulsatility index, the mean flow velocity, and the end-diastolic flow velocity were read from the Doppler recordings. Mean cerebral blood flow was estimated from the /sup 133/Xe clearance curves. The correlation coefficients between the Doppler and the /sup 133/Xe measurements ranged from 0.41 to 0.82. In the subset of 16 first measurements in each infant, there were no statistically significant differences between the correlation coefficients of the various Doppler ultrasound variables, but the correlation coefficients were consistently lower for the pulsatility index than for mean flow velocity or end-diastolic flow velocity, and they were consistently higher for the range-gated than for the continuous-wave Doppler technique.

  19. [Evaluation of gamma camera collimator for regional cerebral blood flow measurements using a 133Xe inhalation method].

    PubMed

    Saegusa, K; Arimizu, N; Uematsu, S

    1984-09-01

    In the measurements of regional cerebral blood flow (rCBF) using inhalation of 133Xe gas, the activity present is generally limited in lower levels than those of usual brain scintigraphy. Measurements with low count-rate are usually resulted in diminishing the accuracies of results obtained. Therefore, it is necessary to make measurements using a high sensitive collimator for getting as much count-rate as possible when a gamma camera is used. The relationships among sensitivity and structures of multi-parallel collimator were mathematically analyzed. The results of analysis suggested that sensitivity usually increased by using a collimator with holes of reduced height and diameter. A prototype multi-parallel collimator with holes of low height and small diameter was made in our laboratory for testing sensitivity and resolution. The collimator possessing 1141 holes of 6 mm phi in hole diameter, 1.5 cm is hole height and septal thickness of 1 mm lead showed 24 times more sensitive than those of a general all purpose collimator supplied by the manufacturer. However, resolution measured in FWHM was of 9 to 14 mm at the collimator face and of 29 to 38 mm at 5 cm from the face. The results indicated that this collimator was useful enough in rCBF measurements with 133Xe inhalation using a gamma camera. The mathematical analysis however, suggested that optimum collimator for rCBF measurements was approximate 4.5 mm phi in hole diameter and 1.0 cm in hole height. PMID:6515050

  20. Concentration Independent Calibration of β-γ Coincidence Detector Using 131mXe and 133Xe

    SciTech Connect

    McIntyre, Justin I.; Cooper, Matthew W.; Carman, April J.; Bowyer, Ted W.; Day, Anthony R.; Haas, Derek A.; Hayes, James C.; Heimbigner, Tom R.; Hubbard, Charles W.; Litke, Kevin E.; Ripplinger, Michael D.; Schrom, Brian T.; Suarez, Reynold

    2009-12-01

    Absolute efficiency calibration of radiometric detectors is frequently difficult and requires careful detector modeling and accurate knowledge of the radioactive source used. In the past we have calibrated the b-g coincidence detector of the Automated Radioxenon Sampler/Analyzer (ARSA) using a variety of sources and techniques which have proven to be less than desirable.[1] A superior technique has been developed that uses the conversion-electron (CE) and x-ray coincidence of 131mXe to provide a more accurate absolute gamma efficiency of the detector. The 131mXe is injected directly into the beta cell of the coincident counting system and no knowledge of absolute source strength is required. In addition, 133Xe is used to provide a second independent means to obtain the absolute efficiency calibration. These two data points provide the necessary information for calculating the detector efficiency and can be used in conjunction with other noble gas isotopes to completely characterize and calibrate the ARSA nuclear detector. In this paper we discuss the techniques and results that we have obtained.

  1. Sources of variability of resting cerebral blood flow in healthy subjects: a study using 133Xe SPECT measurements

    PubMed Central

    Henriksen, Otto M; Kruuse, Christina; Olesen, Jes; Jensen, Lars T; Larsson, Henrik B W; Birk, Steffen; Hansen, Jakob M; Wienecke, Troels; Rostrup, Egill

    2013-01-01

    Measurements of cerebral blood flow (CBF) show large variability among healthy subjects. The aim of the present study was to investigate the relative effect of established factors influencing CBF on the variability of resting CBF. We retrospectively analyzed spontaneous variability in 430 CBF measurements acquired in 152 healthy, young subjects using 133Xe single-photon emission computed tomography. Cerebral blood flow was correlated positively with both end-tidal expiratory PCO2 (PETCO2) and female gender and inversely with hematocrit (Hct). Between- and within-subject CO2 reactivity was not significantly different. Including PETCO2, Hct and gender in the model reduced between-subject and within-subject variance by 14% and 13.5%, respectively. Within-subject variability was mainly influenced by PETCO2 and between-subject variability mostly by Hct, whereas gender appeared to be of little added value when Hct was also accounted for. The present study confirms large between-subject variability in CBF measurements and that gender, Hct, and PETCO2 explain only a small part of this variability. This implies that a large fraction of CBF variability may be due to unknown factors such as differences in neuron density or metabolism that could be subject for further studies. PMID:23403374

  2. Adsorption and desorption of noble gases on activated charcoal: I. 133Xe studies in a monolayer and packed bed.

    PubMed

    Scarpitta, S C; Harley, N H

    1990-10-01

    Detailed desorption studies using petroleum-based activated charcoals were conducted in monolayers and packed beds. Less extensive studies were conducted on several other types of charcoal. Kinetic studies, using 133Xe, demonstrated the existence of a micropore volume with entrance capillaries that together determined the response characteristics of charcoal to external concentration gradients of tracer gases. This new two-phase model, composed of micropores and entrance capillaries, describes the desorption dynamics of an adsorbed gas in the presence of water vapor. Condensed water vapor in the entrance capillaries of the charcoal reduced the effective pore radius and increased the diffusion half-time. Water could also adversely affect the integrating capability of the charcoal dramatically if the adsorbed water completely blocked the entrance capillaries. The amount of adsorbed water required to block the capillaries varied with the charcoal type and was termed here as the "break-point." The desorption parameters measured in this work can be used to design an improved passive Rn monitor to effectively integrate during a 3-7 d exposure period by eliminating the adverse effects of water vapor. The improved canister design would provide more accurate and reproducible measurements of indoor Rn concentrations than are currently available. PMID:2398007

  3. /sup 133/Xe blood flow monitoring during arteriovenous malformation resection: a case of intraoperative hyperperfusion with subsequent brain swelling

    SciTech Connect

    Young, W.L.; Solomon, R.A.; Prohovnik, I.; Ornstein, E.; Weinstein, J.; Stein, B.M.

    1988-04-01

    Measurement of regional cerebral blood flow (rCBF) using the i.v. 133Xe technique was carried out during resection of a right temporooccipital arteriovenous malformation (AVM) with ipsilateral middle and posterior cerebral arterial supply. Intraoperatively, a rCBF detector was in place over the right frontotemporal area, about 5 to 6 cm from the border of the AVM. Anesthesia was 0.75% isoflurane in oxygen and nitrous oxide. After dural exposure, the rCBF was 27 ml/100 g/min at a pCO2 of 29 mm Hg and a mean arterial pressure (MAP) of 90 mm Hg. The pCO2 was then elevated to 40 mm Hg, and the rCBF was increased to 55 ml/100 g/min at a MAP of 83 mm Hg. After AVM removal, the rCBF rose to 50 ml/100 g/min at a pCO2 of 27 mm Hg and a MAP of 75 mm Hg. The pCO2 was elevated to 33 mm Hg and the rCBF increased to 86 ml/100 g/min at a MAP of 97 mm Hg. During skin closure, the rCBF was 94 ml/100 g/min at a pCO2 of 26 mm Hg and a MAP of 97 mm Hg. The patient was neurologically normal postoperatively except for a mild, new visual field defect. After 2 to 3 days, the patient gradually developed lethargy, confusion, and nausea with relatively normal blood pressure. An angiogram revealed residual enlargement of the posterior cerebral artery feeding vessel. Computed tomography showed edema extending from the area of AVM resection as far as the frontal region, producing a significant midline shift anteriorly. Intraoperative rCBF monitoring revealed significant hyperperfusion after AVM resection, which was associated with signs and symptoms of the normal perfusion pressure breakthrough syndrome.

  4. Cerebral hemodynamics in patients with moyamoya disease. A study of regional cerebral blood flow by the /sup 133/Xe inhalation method

    SciTech Connect

    Takeuchi, S.; Tanaka, R.; Ishii, R.; Tsuchida, T.; Kobayashi, K.; Arai, H.

    1985-05-01

    Regional cerebral blood flow was measured by the /sup 133/Xe inhalation method in 20 young patients with moyamoya disease and five young healthy volunteers. Most patients showed low values of mean hemispheric blood flow in both hemispheres. Regional cerebral blood flow was at a low value in the upper frontal region and at an almost average value in the posterotemporal and occipital regions, which was different from the ''hyperfrontal'' pattern in healthy volunteers. Regional cerebral blood flow was reduced evenly by hyperventilation. By 5% CO/sub 2/ inhalation, regional cerebral blood flow was increased in the temporooccipital regions and was nearly unchanged or decreased in the frontal region.

  5. Effects of selected materials and geometries on the beta dose equivalent rate in a tissue equivalent phantom immersed in infinite clouds of 133Xe.

    PubMed

    Piltingsrud, H V; Gels, G L

    1986-06-01

    Most calculations of dose equivalent (D.E.) rates at 70-micron tissue depths in tissue equivalent (T.E.) phantoms from infinite clouds (radius exceeds maximum beta range in air) of 133Xe do not consider the possible effects of clothing overlays. Consequently, a series of measurements were made using a 1-mm-thick plastic scintillation detector assembly mounted in a tissue equivalent (T.E.) phantom with an overlay of 70 micron of T.E. material. This assembly was placed in an infinite cloud containing a known concentration of 133Xe. Material samples were placed at selected distances from the detector phantom, both individually and in various combinations. Pulse-height spectra resulting from beta radiations were converted to relative D.E. rates at a 70-micron tissue depth. The relative D.E. rates were reduced from values with no clothing cover by as little as 45% when placing a single thin nylon cloth 1 cm from the phantom, to 94% for a T-shirt material plus wool material plus denim placed 1/2, 1 and 3 cm, respectively, from the phantom. The results indicate that even loosely fitting clothing can have an important effect on reducing the D.E. rate. Close-fitting clothing appears to provide better protection.

  6. Effects of selected materials and geometries on the beta dose equivalent rate in a tissue equivalent phantom immersed in infinite clouds of 133Xe.

    PubMed

    Piltingsrud, H V; Gels, G L

    1986-06-01

    Most calculations of dose equivalent (D.E.) rates at 70-micron tissue depths in tissue equivalent (T.E.) phantoms from infinite clouds (radius exceeds maximum beta range in air) of 133Xe do not consider the possible effects of clothing overlays. Consequently, a series of measurements were made using a 1-mm-thick plastic scintillation detector assembly mounted in a tissue equivalent (T.E.) phantom with an overlay of 70 micron of T.E. material. This assembly was placed in an infinite cloud containing a known concentration of 133Xe. Material samples were placed at selected distances from the detector phantom, both individually and in various combinations. Pulse-height spectra resulting from beta radiations were converted to relative D.E. rates at a 70-micron tissue depth. The relative D.E. rates were reduced from values with no clothing cover by as little as 45% when placing a single thin nylon cloth 1 cm from the phantom, to 94% for a T-shirt material plus wool material plus denim placed 1/2, 1 and 3 cm, respectively, from the phantom. The results indicate that even loosely fitting clothing can have an important effect on reducing the D.E. rate. Close-fitting clothing appears to provide better protection. PMID:3710789

  7. Effects of selected materials and geometries on the beta dose equivalent rate in a tissue equivalent phantom immersed in infinite clouds of 133Xe

    SciTech Connect

    Piltingsrud, H.V.; Gels, G.L.

    1986-06-01

    Most calculations of dose equivalent (D.E.) rates at 70-micron tissue depths in tissue equivalent (T.E.) phantoms from infinite clouds (radius exceeds maximum beta range in air) of /sup 133/Xe do not consider the possible effects of clothing overlays. Consequently, a series of measurements were made using a 1-mm-thick plastic scintillation detector assembly mounted in a tissue equivalent (T.E.) phantom with an overlay of 70 micron of T.E. material. This assembly was placed in an infinite cloud containing a known concentration of /sup 133/Xe. Material samples were placed at selected distances from the detector phantom, both individually and in various combinations. Pulse-height spectra resulting from beta radiations were converted to relative D.E. rates at a 70-micron tissue depth. The relative D.E. rates were reduced from values with no clothing cover by as little as 45% when placing a single thin nylon cloth 1 cm from the phantom, to 94% for a T-shirt material plus wool material plus denim placed 1/2, 1 and 3 cm, respectively, from the phantom. The results indicate that even loosely fitting clothing can have an important effect on reducing the D.E. rate. Close-fitting clothing appears to provide better protection.

  8. A method for estimating (41)Ar, (85)(,88)Kr and (131m,133)Xe doses to non-human biota.

    PubMed

    Vives I Batlle, J; Jones, S R; Copplestone, D

    2015-06-01

    A method is presented for estimating (41)Ar, (85,88)Kr and (131m,133)Xe dose rates to terrestrial wildlife without having to resort to comparisons with analogue radionuclides. The approach can be used to calculate the dose rates arising from external exposures to given ambient air concentrations of these isotopes. Dose conversion coefficient (DCC) values for a range of representative organisms are calculated, using a Monte Carlo approach to generate absorbed fractions based on representing animals as reference ellipsoid geometries. Plume immersion is the main component of the total DCC. DCC values calculated for a human-sized organism are compared with human dose conversion factors from ICRP Publication 119, demonstrating the consistency of the biota approach with that for humans. An example of application is provided for hypothetical nuclear power plant atmospheric discharges with associated exposures to birds and insects. In this example, the dose rates appear to be dominated by (133)Xe and (88)Kr, respectively. The biota considered would be protected from the effects of noble gas radiation from a population protection perspective.

  9. A method for estimating (41)Ar, (85)(,88)Kr and (131m,133)Xe doses to non-human biota.

    PubMed

    Vives I Batlle, J; Jones, S R; Copplestone, D

    2015-06-01

    A method is presented for estimating (41)Ar, (85,88)Kr and (131m,133)Xe dose rates to terrestrial wildlife without having to resort to comparisons with analogue radionuclides. The approach can be used to calculate the dose rates arising from external exposures to given ambient air concentrations of these isotopes. Dose conversion coefficient (DCC) values for a range of representative organisms are calculated, using a Monte Carlo approach to generate absorbed fractions based on representing animals as reference ellipsoid geometries. Plume immersion is the main component of the total DCC. DCC values calculated for a human-sized organism are compared with human dose conversion factors from ICRP Publication 119, demonstrating the consistency of the biota approach with that for humans. An example of application is provided for hypothetical nuclear power plant atmospheric discharges with associated exposures to birds and insects. In this example, the dose rates appear to be dominated by (133)Xe and (88)Kr, respectively. The biota considered would be protected from the effects of noble gas radiation from a population protection perspective. PMID:25863225

  10. Analysis of H2 clearance curves used to measure blood flow in rat sciatic nerve.

    PubMed Central

    Day, T J; Lagerlund, T D; Low, P A

    1989-01-01

    1. By use of the H2 clearance technique, blood flow was measured in the sciatic nerve of healthy, anaesthetized Sprague-Dawley rats at rest, during inferior vena cava occlusion and during 5-hydroxytryptamine infusion. The purpose was to clarify the mechanisms underlying the biexponential curves which are commonly obtained using this technique. 2. An analysis of the frequency distribution of rate constants of 270 nerve and thirty-three arterial samples indicated that H2 clearance rates cluster below 20 ml min-1 100 g-1 and between 70 and 100 ml min-1 100 g-1. This suggests that at least two compartments are present. 3. The contribution of diffusion was studied by recording H2 clearance immediately following circulatory arrest. Slow clearance rates (median = 2.4 ml min-1 100 g-1) were observed, indicating that diffusion is not likely to contribute significantly to nutritive flow under most situations. 4. The contribution of arteriovenous shunts to H2 clearance was assessed by determining H2 clearance during inferior vena cava occlusion and the infusion of 5-hydroxytryptamine. Both manoeuvres caused abolition of, or a significant reduction in the weight of, the fast component which indicates that this compartment is closely related to arteriovenous shunts in nerve. 5. By use of a multi-compartmental model, it was shown that H2 clearance should follow a multi-exponential course, where the weights of the components reflect the relative volumes of each compartment and the exponents represent the relative flow (i.e. flow per unit volume) in each compartment. 6. By use of other mathematical models, estimates were made for the clearance rates attributable to polarographic oxidation of H2 at the tip of the microelectrode (0.2 ml min-1 100 g-1) and to diffusion to air (2 ml min-1 100 g-1). The latter estimate is very close to the measured value of 2.4 ml min-1 100 g-1. 7. These findings indicate that it is possible to separately assess nutritive and non-nutritive flow by

  11. Correlation of elimination fraction area under the curve with total body clearance.

    PubMed

    Grabowski, Tomasz; Raczyńska-Pawelec, Anna; Starościak, Marcin; Jaroszewski, Jerzy Jan

    2016-02-01

    This study attempted to determine the area under the curve ([Formula: see text]), which corresponds to the sum of all elimination processes correlated with the total clearance value. The study attempted to determine the [Formula: see text] based on the coordinates known from classic non-compartmental pharmacokinetics for a single administration of the drug. 318 pharmacokinetics profiles were used for the analysis, obtained from 220 healthy subjects over ten studies. Pharmacokinetic calculations were performed with the use of Phoenix™ WinNonlin(®) 6.3. The leave-one-out (LOO) method was used for model cross-validation. Squared cross-validated correlation coefficient (Q (2)) parameter and the difference between Q (2) and R (2) were calculated as a measure of the internal performance and model predictive ability. A high correlation between the clearance value and [Formula: see text] was demonstrated (R (2) > 0.65). However, only in the case of four studies was it possible to validate the linear model using the leave-one-out validation procedure (R (2) > 0.86). The present study proposed a method of graphical and mathematical determination of the area under the curve for the drug elimination process after a single dose of the drug. Furthermore, the concept of calculating the statistical moments and mean elimination time (MET) only for elimination processes based on [Formula: see text] was presented. The result of this work is also a new method of determining the half-life of elimination phase based on the MET value.

  12. Reproducibility of the /sup 133/Xe inhalation technique in resting studies: task order and sex related effects in healthy young adults

    SciTech Connect

    Warach, S.; Gur, R.C.; Gur, R.E.; Skolnick, B.E.; Obrist, W.D.; Reivich, M.

    1987-12-01

    Repeated applications of the /sup 133/Xe inhalation technique for measuring regional CBF (rCBF) were made during consecutive resting conditions in a sample of young healthy subjects. Subjects were grouped by order and by sex (nine had resting studies as the initial two measurements in a series of four measurement (six men, three women) and six had these measurements later (two men, four women)). Three flow parameters were examined: f1 (fast flow) and IS (initial slope) for gray matter CBF, and CBF-15 for mean CBF (gray and white matter over 15-min integration), as well as w1, the percentage of tissue with fast clearing characteristics. With all groups combined, there were no significant differences between the two resting measurements, and high test-retest correlations were obtained for the flow parameters and w1. Analyses by order and sex grouping revealed, for the flow parameters, significant interactions of test-retest difference with order. Repeated initial studies showed reduced CBF from the first to second measurement, whereas resting studies performed later in the series showed no reduction. Interactions for test-retest difference with sex indicated that reduced CBF in serial measures was more pronounced for women. No hemispheric or regional specificity to account for these effects was found. Correction for PaCO/sub 2/ differences did not alter these results. The results resemble data regarding habituation effects measured for other psychophysiologic measures, and suggest that reduction in CBF for consecutive measurements made on the same day may reflect habituation. This underscores the importance of controlling for effects of habituation on serial measurements of CBF and metabolism.

  13. Computation and Analysis of the Global Distribution of the Radioxenon Isotope 133Xe based on Emissions from Nuclear Power Plants and Radioisotope Production Facilities and its Relevance for the Verification of the Nuclear-Test-Ban Treaty

    NASA Astrophysics Data System (ADS)

    Wotawa, Gerhard; Becker, Andreas; Kalinowski, Martin; Saey, Paul; Tuma, Matthias; Zähringer, Matthias

    2010-05-01

    Monitoring of radioactive noble gases, in particular xenon isotopes, is a crucial element of the verification of the Comprehensive Nuclear-Test-Ban Treaty (CTBT). The capability of the noble gas network, which is currently under construction, to detect signals from a nuclear explosion critically depends on the background created by other sources. Therefore, the global distribution of these isotopes based on emissions and transport patterns needs to be understood. A significant xenon background exists in the reactor regions of North America, Europe and Asia. An emission inventory of the four relevant xenon isotopes has recently been created, which specifies source terms for each power plant. As the major emitters of xenon isotopes worldwide, a few medical radioisotope production facilities have been recently identified, in particular the facilities in Chalk River (Canada), Fleurus (Belgium), Pelindaba (South Africa) and Petten (Netherlands). Emissions from these sites are expected to exceed those of the other sources by orders of magnitude. In this study, emphasis is put on 133Xe, which is the most prevalent xenon isotope. First, based on the emissions known, the resulting 133Xe concentration levels at all noble gas stations of the final CTBT verification network were calculated and found to be consistent with observations. Second, it turned out that emissions from the radioisotope facilities can explain a number of observed peaks, meaning that atmospheric transport modelling is an important tool for the categorization of measurements. Third, it became evident that Nuclear Power Plant emissions are more difficult to treat in the models, since their temporal variation is high and not generally reported. Fourth, there are indications that the assumed annual emissions may be underestimated by factors of two to ten, while the general emission patterns seem to be well understood. Finally, it became evident that 133Xe sources mainly influence the sensitivity of the

  14. An evaluation of the external radiation exposure dosimetry and calculation of maximum permissible concentration values for airborne materials containing 18F, 15O, 13N, 11C and 133Xe.

    PubMed

    Piltingsrud, H V; Gels, G L

    1985-11-01

    To better understand the dose equivalent (D.E.) rates produced by airborne releases of gaseous positron-emitting radionuclides under various conditions of cloud size, a study of the external radiation exposure dosimetry of these radionuclides, as well as negatron, gamma and x-ray emitting 133Xe, was undertaken. This included a calculation of the contributions to D.E. as a function of cloud radii, at tissue depths of 0.07 mm (skin), 3 mm (lens of eye) and 10 mm (whole body) from both the particulate and photon radiations emitted by these radionuclides. Estimates of maximum permissible concentration (MPC) values were also calculated based on the calculated D.E. rates and current regulations for personnel radiation protection (CFR84). Three continuous air monitors, designed for use with 133Xe, were evaluated for applications in monitoring air concentrations of the selected positron emitters. The results indicate that for a given radionuclide and for a cloud greater than a certain radius, personnel radiation dosimeters must respond acceptably to only the photon radiations emitted by the radionuclide to provide acceptable personnel dosimetry. For clouds under that radius, personnel radiation dosimeters must also respond acceptably to the positron or negatron radiations to provide acceptable personnel dosimetry. It was found that two out of the three air concentration monitors may be useful for monitoring air concentrations of the selected positron emitters.

  15. Effect of hematocrit and systolic blood pressure on cerebral blood flow in newborn infants

    SciTech Connect

    Younkin, D.P.; Reivich, M.; Jaggi, J.L.; Obrist, W.D.; Delivoria-Papadopoulos, M.

    1987-06-01

    The effects of hematocrit and systolic blood pressure on cerebral blood flow were measured in 15 stable, low birth weight babies. CBF was measured with a modification of the xenon-133 (/sup 133/Xe) clearance technique, which uses an intravenous bolus of /sup 133/Xe, an external chest detector to estimate arterial /sup 133/Xe concentration, eight external cranial detectors to measure cephalic /sup 133/Xe clearance curves, and a two-compartmental analysis of the cephalic /sup 133/Xe clearance curves to estimate CBF. There was a significant inverse correlation between hematocrit and CBF, presumably due to alterations in arterial oxygen content and blood viscosity. Newborn CBF varied independently of systolic blood pressure between 60 and 84 mm Hg, suggesting an intact cerebrovascular autoregulatory mechanism. These results indicate that at least two of the factors that affect newborn animal CBF are operational in human newborns and may have important clinical implications.

  16. Serum Human Chorionic Gonadotropin (β- hCG) Clearance Curves in Women with Successfully Expectantly Managed Tubal Ectopic Pregnancies: A Retrospective Cohort Study

    PubMed Central

    Helmy, Samir; Mavrelos, Dimitrios; Sawyer, Elinor; Ben-Nagi, Jara; Koch, Marianne; Day, Andrea; Jurkovic, Davor

    2015-01-01

    Objective To establish clearance curves for serum β -hCG in women with successfully expectantly managed tubal ectopic pregnancies. Design Retrospective cohort study. Non- viable tubal ectopic pregnancy was diagnosed on transvaginal ultrasound. If initial serum β hCG was less than 5000 IU/L and patients were asymptomatic, expectant management was offered. Patients underwent serial β hCG measurements until serum β hCG was less than 20 IU/l, or the urine pregnancy test was negative. Setting Early Pregnancy and Gynaecology Assessment Unit, Kings College Hospital, London (December 1998 to July 2006). Patients We included 161 women with diagnosed non-viable tubal ectopic pregnancy who underwent successful expectant management. Main outcome measure Serum β hCG level. Results Mean initial serum β- hCG was 488 IU/L (41 - 4883) and median serum β hCG clearance time was 19 days (5 - 82). The average half-life of β hCG clearance was 82.5 hours (±SD 50.2) in patients with steadily declining serum β- hCG levels compared to 106.7 hours (±SD 72.0) in patients with primarily plateauing β-hCG levels in the declining phase. However, these differences were not significant (p>0.05). Conclusion We identified a median follow-up of 19 days until serum β hCG clearance in women with tubal ectopic pregnancy and successful expectant management. Although non- significant, women with initially plateauing serum β hCG showed a longer follow-up time until clearance compared to women with steadily declining β hCG levels. This information may serve as a guideline enabling clinicians to predict the length of follow-up for women with tubal ectopic pregnancy and expectant management. PMID:26135923

  17. Hemodynamics of erection in man

    SciTech Connect

    Shirai, M.; Ishii, N.

    1981-02-01

    Inquiry was made into the theory that closure of the efferent vein from the corpora cavernosa is essential for erection of the human penis. To determine whether the venous closure is indeed a prerequisite to human penile erection, two tests were carried out in men: (1) direct infusion in 133Xe into corpora cavernosa and (2) performance of carvernosography. In each case, penile erection was induced by providing the subject with sexual stimulation. The behavioral changes were studied through the 133Xe clearance curve and the contrast medium, respectively. When the penis remained flaccid, the 133Xe clearance curve followed a gentle path and the contrast medium could be noted within the penis for a relatively long period. However, on erection with sexual stimulation, the 133Xe clearance curve fell rapidly instead of following the gentle course expected in the case of venous closure. Also, the contrast medium quickly flowed out of the corpora cavernosa. The human penis therefore can well erect without closure of the efferent vein from the corpora cavernosa.

  18. Hemodialysis clearance of theophylline.

    PubMed

    Slaughter, R L; Green, L; Kohli, R

    1982-01-01

    The serum hemodialysis clearance of theophylline was determined in 4 patients compared to systemic serum clearance off dialysis in 3 patients. The serum extraction ratio values obtained were compared to those of urea. Hemodialysis clearance of theophylline averaged 84.3 +/- 11.6 ml/min (mean +/- SD), and extraction ratios obtained were found to be a fairly consistent fraction of the urea extraction ratio (0.72 +/- 0.08). Hemodialysis clearance increased total body clearance (ClTB) off dialysis by 130%, 387%, and 176% in the patients who had their theophylline serum clearance estimated off dialysis. Difference in reported hemodialysis clearance are probably related to the type of dialyser used. Studies utilizing hollow fiber systems (the present study) consistently yielded higher theophylline dialysis clearance values than those using coil systems (84.3% to 88.1 ml/min versus 32 to 39.4 ml/min). Patients receiving theophylline on hemodialysis should be closely monitored for bronchospasm during and after the hemodialysis procedure. Measurement of serum concentrations should be employed to facilitate dosage increases during hemodialysis.

  19. Effect of Internal Clearance on Load Distribution and Life of Radially Loaded Ball and Roller Bearings

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Zaretsky, Erwin V.; Poplawski, Joseph V.

    2012-01-01

    The effect of internal clearance on radially loaded deepgroove ball and cylindrical roller bearing load distribution and fatigue life was determined for four clearance groups defined in the bearing standards. The analysis was extended to negative clearance (interference) conditions to produce a curve of life factor versus internal clearance. Rolling-element loads can be optimized and bearing life maximized for a small negative operating clearance. Life declines gradually with positive clearance and rapidly with increasing negative clearance. Relationships were found between bearing life and internal clearance as a function of ball or roller diameter, adjusted for load. Results are presented as life factors for radially loaded bearings independent of bearing size or applied load. In addition, a modified Stribeck Equation is presented that relates the maximum rolling-element load to internal bearing clearance.

  20. SDAT – Analysis of 131mXe with 133Xe Interference

    SciTech Connect

    Biegalski, Steven R.; Foltz Biegalski, Kendra M.; Haas, Derek A.

    2009-12-01

    The Spectral Deconvolution Analysis Tool (SDAT) software was developed at The University of Texas at Austin. SDAT utilizes a standard spectrum technique for the analysis of beta-gamma coincidence spectra. Testing was performed on the software to compare the standard spectrum analysis technique with a region of interest (ROI) analysis technique. Experimentally produced standard spectra and sample data were produced at the Nuclear Engineering Teaching Laboratory (NETL) TRIGA reactor. The results of the testing showed that the standard spectrum technique had lower errors than the ROI analysis technique for samples with low counting statistics. In contrast, the ROI analysis technique outperformed the standard spectrum technique in high counting statistics samples. It was also shown that the standard spectrum technique benefitted from a compression of the number of channels within the spectra.

  1. Site clearance working group

    SciTech Connect

    1997-03-01

    The Gulf of Mexico and Louisiana continue to be areas with a high level of facility removal, and the pace of removal is projected to increase. Regulations were promulgated for the Gulf of Mexico and Louisiana requiring that abandoned sites be cleared of debris that could interfere with fishing and shrimping activities. The site clearance regulations also required verification that the sites were clear. Additionally, government programs were established to compensate fishermen for losses associated with snagging their equipment on oil and gas related objects that remained on the water bottoms in areas other than active producing sites and sites that had been verified as clear of obstructions and snags. The oil and gas industry funds the compensation programs. This paper reviews the regulations and evolving operating practices in the Gulf of Mexico and Louisiana where site clearance and fisherman`s gear compensation regulations have been in place for a number of years. Although regulations and guidelines may be in place elsewhere in the world, this paper focuses on the Gulf of Mexico and Louisiana. Workshop participants are encouraged to bring up international issues during the course of the workshop. Additionally, this paper raises questions and focuses on issues that are of concern to the various Gulf of Mexico and Louisiana water surface and water bottom stakeholders. This paper does not have answers to the questions or issues. During the workshop participants will debate the questions and issues in an attempt to develop consensus opinions and/or make suggestions that can be provided to the appropriate organizations, both private and government, for possible future research or policy adjustments. Site clearance and facility removal are different activities. Facility removal deals with removal of the structures used to produce oil and gas including platforms, wells, casing, piles, pipelines, well protection structures, etc.

  2. Pulmonary function and clearance after prolonged sulfuric acid aerosol exposure

    SciTech Connect

    Ives, P.J. ); Gerrity, T.R.; DeWitt, P.; Folinsbee, L.J. )

    1991-03-15

    The authors studied pulmonary function and clearance responses after a 4 H exposure to 75-100 {mu}g/m{sup 3} sulfuric acid aerosol (SAA). Healthy subjects, who exercised for 30 min/H at ventilation of about 25 L/min, were exposed once to clean air and once to SAA. Oral hygiene and acidic juice gargle were used to minimize oral ammonia. Lung function tests, including spirometry, plethysmography, and partial flow-volume (PEFV) curves were performed before and after exposure. Clearance of 99m-Technetium labeled iron oxide was assessed after each exposure. The first moment of fractional tracheobronchial retention (M1TBR), after correcting for 24 H retention and normalizing to time zero, was used as an index of clearance. There were no significant changes in lung volumes, airways resistance, or maximum expiratory flows after SAA exposure. Flow at 40% of total lung capacity on PEFV curves decreased 17% (NS) after SAA exposure. Tracheobronchial clearance was accelerated after a single exposure to SAA; M1TBR decreased from 73 {plus minus} 5 min (air) to 69 {plus minus} 5 min (SAA). These results suggest that acute prolonged exposure to low levels of SAA has minimal effects on lung mechanics in healthy subjects but does produce a modest acceleration of particle clearance.

  3. Turbomachinery Clearance Control

    NASA Technical Reports Server (NTRS)

    Chupp, Raymond E.; Hendricks, Robert C.; Lattime, Scott B.; Steinetz, Bruce M.; Aksit, Mahmut F.

    2007-01-01

    Controlling interface clearances is the most cost effective method of enhancing turbomachinery performance. Seals control turbomachinery leakages, coolant flows and contribute to overall system rotordynamic stability. In many instances, sealing interfaces and coatings are sacrificial, like lubricants, giving up their integrity for the benefit of the component. They are subjected to abrasion, erosion, oxidation, incursive rubs, foreign object damage (FOD) and deposits as well as extremes in thermal, mechanical, aerodynamic and impact loadings. Tribological pairing of materials control how well and how long these interfaces will be effective in controlling flow. A variety of seal types and materials are required to satisfy turbomachinery sealing demands. These seals must be properly designed to maintain the interface clearances. In some cases, this will mean machining adjacent surfaces, yet in many other applications, coatings are employed for optimum performance. Many seals are coating composites fabricated on superstructures or substrates that are coated with sacrificial materials which can be refurbished either in situ or by removal, stripping, recoating and replacing until substrate life is exceeded. For blade and knife tip sealing an important class of materials known as abradables permit blade or knife rubbing without significant damage or wear to the rotating element while maintaining an effective sealing interface. Most such tip interfaces are passive, yet some, as for the high-pressure turbine (HPT) case or shroud, are actively controlled. This work presents an overview of turbomachinery sealing. Areas covered include: characteristics of gas and steam turbine sealing applications and environments, benefits of sealing, types of standard static and dynamics seals, advanced seal designs, as well as life and limitations issues.

  4. Some Practical Payments Clearance Algorithms

    NASA Astrophysics Data System (ADS)

    Kumlander, Deniss

    The globalisation of corporations' operations has produced a huge volume of inter-company invoices. Optimisation of those known as payment clearance can produce a significant saving in costs associated with those transfers and handling. The paper revises some common and so practical approaches to the payment clearance problem and proposes some novel algorithms based on graphs theory and heuristic totals' distribution.

  5. Effect of oral N-acetylcysteine on mucus clearance.

    PubMed

    Millar, A B; Pavia, D; Agnew, J E; Lopez-Vidriero, M T; Lauque, D; Clarke, S W

    1985-07-01

    Oral N-acetylcysteine has been advocated as a mucolytic agent for use in chronic bronchitis. We have investigated the effects of regular use of this drug at a dose of 200 mg thrice daily for 4 weeks in nine patients with chronic bronchitis on lung function, lung mucociliary clearance and sputum viscosity in a controlled, double-blind, crossover study. No significant differences were found in lung function, mucociliary clearance curves or sputum viscosity following treatment with N-acetylcysteine compared to control or placebo measurements.

  6. Dual clearance squeeze film damper

    NASA Technical Reports Server (NTRS)

    Fleming, D. P. (Inventor)

    1985-01-01

    A dual clearance hydrodynamic liquid squeeze film damper for a gas turbine engine is described. Under normal operating conditions, the device functions as a conventional squeeze film damper, using only one of its oil films. When an unbalance reaches abusive levels, as may occur with a blade loss or foreign object damage, a second, larger clearance film becomes active, controlling vibration amplitudes in a near optimum manner until the engine can be safely shut down and repaired.

  7. Bradford Curves.

    ERIC Educational Resources Information Center

    Rousseau, Ronald

    1994-01-01

    Discussion of informetric distributions shows that generalized Leimkuhler functions give proper fits to a large variety of Bradford curves, including those exhibiting a Groos droop or a rising tail. The Kolmogorov-Smirnov test is used to test goodness of fit, and least-square fits are compared with Egghe's method. (Contains 53 references.) (LRW)

  8. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the...

  9. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most...

  10. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the...

  11. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most...

  12. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 1 2013-01-01 2013-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most...

  13. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the...

  14. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the...

  15. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 1 2012-01-01 2012-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most...

  16. 14 CFR 25.925 - Propeller clearance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 1 2011-01-01 2011-01-01 false Propeller clearance. 25.925 Section 25.925... STANDARDS: TRANSPORT CATEGORY AIRPLANES Powerplant General § 25.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances with the airplane at maximum weight, with the most...

  17. 14 CFR 23.925 - Propeller clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 1 2014-01-01 2014-01-01 false Propeller clearance. 23.925 Section 23.925... STANDARDS: NORMAL, UTILITY, ACROBATIC, AND COMMUTER CATEGORY AIRPLANES Powerplant General § 23.925 Propeller clearance. Unless smaller clearances are substantiated, propeller clearances, with the airplane at the...

  18. Inherited Disorders of Bilirubin Clearance

    PubMed Central

    Memon, Naureen; Weinberger, Barry I; Hegyi, Thomas; Aleksunes, Lauren M

    2016-01-01

    Inherited disorders of hyperbilirubinemia may be caused by increased bilirubin production or decreased bilirubin clearance. Reduced hepatic bilirubin clearance can be due to defective 1) unconjugated bilirubin uptake and intrahepatic storage, 2) conjugation of glucuronic acid to bilirubin (e.g. Gilbert syndrome, Crigler-Najjar syndrome, Lucey-Driscoll syndrome, breast milk jaundice), 3) bilirubin excretion into bile (Dubin-Johnson syndrome), or 4) conjugated bilirubin re-uptake (Rotor syndrome). In this review, the molecular mechanisms and clinical manifestations of these conditions are described, as well as current approaches to diagnosis and therapy. PMID:26595536

  19. Inherited disorders of bilirubin clearance.

    PubMed

    Memon, Naureen; Weinberger, Barry I; Hegyi, Thomas; Aleksunes, Lauren M

    2016-03-01

    Inherited disorders of hyperbilirubinemia may be caused by increased bilirubin production or decreased bilirubin clearance. Reduced hepatic bilirubin clearance can be due to defective (i) unconjugated bilirubin uptake and intrahepatic storage, (ii) conjugation of glucuronic acid to bilirubin (e.g., Gilbert syndrome, Crigler-Najjar syndrome, Lucey-Driscoll syndrome, breast milk jaundice), (iii) bilirubin excretion into bile (Dubin-Johnson syndrome), or (iv) conjugated bilirubin re-uptake (Rotor syndrome). In this review, the molecular mechanisms and clinical manifestations of these conditions are described, as well as current approaches to diagnosis and therapy. PMID:26595536

  20. The effects of selected air pollutants on clearance of titanic oxide particles from the lungs of rats.

    PubMed

    Ferin, J; Leach, L J

    1975-09-01

    A procedure utilizing the lung clearance kinetics of titanic oxide (TiO2) particles was used to determine the effects of inhaled sulphur dioxide (SO2) and nitrogen oxides (NO x) on particle clearance. The procedure is reproducible and mainly tests clearance mechanisms involving alveolar macrophages and the mucociliary transport system at the alveolobronchial clearance pathway. At low SO2 or NOx exposures enhanced particle clearance was observed. Lung clearance was depressed at 15 and 24 ppm of NO2 after 22 exposures as well as at 20 ppm of SO2 after 11 exposures, and also at 1 ppm of SO2 after 25 exposures. Dose-response curves for the SO2 and NOx exposures showed differences explainable by the routes by which these gases reach the alveolar macrophages.

  1. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 22 Foreign Relations 1 2011-04-01 2011-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a...

  2. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical...

  3. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical...

  4. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical...

  5. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical...

  6. 30 CFR 18.24 - Electrical clearances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Electrical clearances. 18.24 Section 18.24... APPROVAL OF MINING PRODUCTS ELECTRIC MOTOR-DRIVEN MINE EQUIPMENT AND ACCESSORIES Construction and Design Requirements § 18.24 Electrical clearances. Minimum clearances between uninsulated electrical...

  7. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 22 Foreign Relations 1 2010-04-01 2010-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a...

  8. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 22 Foreign Relations 1 2013-04-01 2013-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a...

  9. 22 CFR 16.6 - Security clearances.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 22 Foreign Relations 1 2014-04-01 2014-04-01 false Security clearances. 16.6 Section 16.6 Foreign Relations DEPARTMENT OF STATE PERSONNEL FOREIGN SERVICE GRIEVANCE SYSTEM § 16.6 Security clearances. The agencies shall use their best endeavors to expedite security clearances whenever necessary to ensure a...

  10. Apoptotic Cell Clearance in Development.

    PubMed

    Shklover, Jeny; Levy-Adam, Flonia; Kurant, Estee

    2015-01-01

    Programmed cell death and its specific form apoptosis play an important role during development of multicellular organisms. They are crucial for morphogenesis and organ sculpting as well as for adjusting cell number in different systems. Removal of apoptotic cells is the last critical step of apoptosis. Apoptotic cells are properly and efficiently recognized and eliminated through phagocytosis, which is performed by professional and nonprofessional phagocytes. Phagocytosis of apoptotic cells or apoptotic cell clearance is a dynamic multistep process, involving interactions between phagocytic receptors and ligands on apoptotic cells, which are highly conserved in evolution. However, this process is extremely redundant in mammals, containing multiple factors playing similar roles in the process. Using model organisms such as Caenorhabditis elegans, Drosophila melanogaster, zebrafish, and mouse permits addressing fundamental questions in developmental cell clearance by a comprehensive approach including powerful genetics and cell biological tools enriched by live imaging. Recent studies in model organisms have enhanced significantly our understanding of the molecular and cellular basis of apoptotic cell clearance during development. Here, we review the current knowledge and illuminate the great potential of the research performed in genetic models, which opens new directions in developmental biology.

  11. Inspiratory flow and intrapulmonary gas distribution

    SciTech Connect

    Rehder, K.; Knopp, T.J.; Brusasco, V.; Didier, E.P.

    1981-01-01

    The effect of flow of inspired gas on intrapulmonary gas distribution was examined by analysis of regional pulmonary /sup 133/Xe clearances and of total pulmonary /sup 133/Xe clearance measured at the mouth after equilibration of the lungs with /sup 133/Xe. Five awake healthy volunteers (24 to 40 yr of age) and another 5 healthy, anesthetized-paralyzed volunteers (26 to 28 yr of age) were studied while they were in the right lateral decubitus position. The awake subjects were studied at 3 inspiratory flows (0.4, 0.7, and 1.0 L/s) and the anesthetized-paralyzed subjects at 4 inspiratory flows (0.2, 0.5, 1.1, and 1.6 L/s). Interregional differences in /sup 133/Xe clearances along the vertical axis were significantly less during anesthesia-paralysis and mechanical ventilation than during spontaneous breathing in the awake state. No differences in the regional or total pulmonary /sup 133/Xe clearances were detected at these different flows in either of the two states, i.e., the difference between the awake and anesthetized-paralyzed states persisted.

  12. Curves and Their Properties.

    ERIC Educational Resources Information Center

    Yates, Robert C.

    This volume, a reprinting of a classic first published in 1952, presents detailed discussions of 26 curves or families of curves, and 17 analytic systems of curves. For each curve the author provides a historical note, a sketch or sketches, a description of the curve, a discussion of pertinent facts, and a bibliography. Depending upon the curve,…

  13. Potential impact of mangrove clearance on biomass and biomass size spectra of nematode along the Sudanese Red Sea coast.

    PubMed

    Sabeel, Rasha Adam Osman; Vanreusel, Ann

    2015-02-01

    The potential effect of mangrove clearance on nematode assemblage biomass, biomass size spectra (NBSS) and abundance/biomass curves (ABC) was investigated in three sites representing a varying degree of mangrove clearance as well as in three stations established at each sites representing high-, mid- and low-water levels. Results revealed significant differences in sediment and nematode characteristics between the three sites. Although both the cleared and the intact mangrove had comparable biomass values, clear differences in biomass size spectra and abundance biomass curves were observed. The results suggested that the variation in the silt fraction and the food quality positively affected the total biomass. Mangrove clearance has caused a shift from a unimodal to a bimodal biomass size spectrum at all water levels, owing to an increase in smaller-bodied opportunistic non-selective deposit feeding nematodes. The ABC further confirmed the effect of clearance by classifying the cleared mangrove as moderately to grossly disturbed.

  14. D0 Solenoid Chimney Routing Clearances

    SciTech Connect

    Rucinski, R.; /Fermilab

    1994-02-23

    coordinates. This curve is stored in drawing file 3823.111-ME317164, 'Solenoid-CC south face-chimney contour layout'. All drawings mentioned above are kept in hard copy form in the D-Zero drawing files. The electronic 'master' copy is kept in the XDCS drawing control system, dOms vault. The information contained in this engineering note could be very useful for those who are interested in the clearances and shape of the solenoid chimney path. It could even be of use to future designers and engineers involved with the VLPC project which is planned.

  15. Pulmonary clearance of radiotracers after positive end-expiratory pressure or acute lung injury

    SciTech Connect

    Barrowcliffe, M.P.; Zanelli, G.D.; Jones, J.G.

    1989-01-01

    In anesthetized rabbits we measured clearance from lung to blood of eight aerosolized technetium-99m-labeled compounds: diethylenetriaminepentaacetate (99mTc-DTPA); cytochrome c; myoglobin; a myoglobin polymer; albumin; and anionic, cationic, and neutral dextrans of equivalent molecular size. We investigated the effect of applying positive end-expiratory pressure (PEEP) and, on a subsequent occasion, of injecting oleic acid intravenously to produce acute lung injury on the pulmonary clearance rate. Base-line clearance rates were monoexponential and varied with the molecular weights of the radiotracers. For each tracer the rate of clearance was increased a similar degree by either PEEP or oleic acid. However, with PEEP, clearance remained monoexponential, whereas after oleic acid, smaller molecular-weight radiotracers had multiexponential clearance curves. This suggests that after oleic acid the alveolar epithelium breaks down in a nonuniform fashion. We conclude that differentiation of the effect of PEEP from that of severe lung injury caused by oleic acid is not readily accomplished by either increasing the size of the tracer molecule or by varying the molecular charge.

  16. Intelligent Engine Systems: HPT Clearance Control

    NASA Technical Reports Server (NTRS)

    2008-01-01

    The Advanced Thermally Actuated Clearance Control System underwent several studies. Improved flow path isolation quantified what can be gained by making the HPT case nearly adiabatic. The best method of heat transfer was established, and finally two different borrowed air cooling circuits were evaluated to be used for the HPT Active Clearance Control System.

  17. 19 CFR 122.77 - Clearance certificate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Clearance certificate. 122.77 Section 122.77 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Documents Required for Clearance and Permission To Depart;...

  18. 30 CFR 56.7018 - Hand clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand clearance. 56.7018 Section 56.7018 Mineral... Drilling § 56.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling....

  19. 30 CFR 56.7018 - Hand clearance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand clearance. 56.7018 Section 56.7018 Mineral... Drilling § 56.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling....

  20. 30 CFR 57.7018 - Hand clearance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand clearance. 57.7018 Section 57.7018 Mineral... Drilling-Surface Only § 57.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling. Drilling—Underground Only...

  1. 30 CFR 57.7028 - Hand clearance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand clearance. 57.7028 Section 57.7028 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Drilling-Underground Only § 57.7028 Hand clearance. Persons shall not rest their hands on the chuck...

  2. 30 CFR 57.7028 - Hand clearance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand clearance. 57.7028 Section 57.7028 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Drilling-Underground Only § 57.7028 Hand clearance. Persons shall not rest their hands on the chuck...

  3. 30 CFR 57.7018 - Hand clearance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand clearance. 57.7018 Section 57.7018 Mineral... Drilling-Surface Only § 57.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling. Drilling—Underground Only...

  4. 30 CFR 57.7018 - Hand clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand clearance. 57.7018 Section 57.7018 Mineral... Drilling-Surface Only § 57.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling. Drilling—Underground Only...

  5. 30 CFR 56.7018 - Hand clearance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Hand clearance. 56.7018 Section 56.7018 Mineral... Drilling § 56.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling....

  6. 30 CFR 57.7018 - Hand clearance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand clearance. 57.7018 Section 57.7018 Mineral... Drilling-Surface Only § 57.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling. Drilling—Underground Only...

  7. 30 CFR 57.7028 - Hand clearance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Hand clearance. 57.7028 Section 57.7028 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Drilling-Underground Only § 57.7028 Hand clearance. Persons shall not rest their hands on the chuck...

  8. 30 CFR 57.7018 - Hand clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand clearance. 57.7018 Section 57.7018 Mineral... Drilling-Surface Only § 57.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling. Drilling—Underground Only...

  9. 30 CFR 57.7028 - Hand clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Hand clearance. 57.7028 Section 57.7028 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Drilling-Underground Only § 57.7028 Hand clearance. Persons shall not rest their hands on the chuck...

  10. 30 CFR 56.7018 - Hand clearance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Hand clearance. 56.7018 Section 56.7018 Mineral... Drilling § 56.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling....

  11. 30 CFR 56.7018 - Hand clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand clearance. 56.7018 Section 56.7018 Mineral... Drilling § 56.7018 Hand clearance. Persons shall not hold the drill steel while collaring holes, or rest their hands on the chuck or centralizer while drilling....

  12. 30 CFR 57.7028 - Hand clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Hand clearance. 57.7028 Section 57.7028 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND... Drilling-Underground Only § 57.7028 Hand clearance. Persons shall not rest their hands on the chuck...

  13. AHERA CLEARANCE AT TWENTY ABATEMENT SITES

    EPA Science Inventory

    A study was conducted during the summer of 1988 to document Asbestos Hazard Emergency Response Act (AHERA) clearance air-sampling practices and clearance concentrations of airborne asbestos at 20 asbestos-abatement sites in New Jersey. Each abatement took place in a school buildi...

  14. Explicit superconic curves.

    PubMed

    Cho, Sunggoo

    2016-09-01

    Conics and Cartesian ovals are extremely important curves in various fields of science. In addition, aspheric curves based on conics are useful in optical design. Superconic curves, recently suggested by Greynolds, are extensions of both conics and Cartesian ovals and have been applied to optical design. However, they are not extensions of aspheric curves based on conics. In this work, we investigate another type of superconic curves. These superconic curves are extensions of not only conics and Cartesian ovals but also aspheric curves based on conics. Moreover, these are represented in explicit form, while Greynolds's superconic curves are in implicit form. PMID:27607506

  15. Effects of lung volume on clearance of solutes from the air spaces of lungs

    SciTech Connect

    Peterson, B.T.; James, H.L.; McLarty, J.W.

    1988-03-01

    Several investigators have shown that the clearance rate of aerosolized 99mTc-labeled diethylenetriamine pentaacetate (DTPA, mol wt = 492, radius = 0.6 nm) from the air spaces of the lungs of humans and experimental animals increases with lung volume. To further investigate this phenomenon we performed a compartmental analysis of the 2-h clearance of DTPA from the lungs of anesthetized sheep using a new method to more accurately correct for the effects of DTPA recirculation. This analysis showed that the DTPA clearance in eight sheep ventilated with zero end-expired pressure was best described by a one-compartment model with a clearance rate of 0.42 +/- 0.15%/min. Ventilating eight sheep with an end-expired pressure of 10 cmH/sub 2/O throughout the study increased the end-expired volume 0.4 +/- 0.1 liter BTPS and created a clearance curve that was best described by a two-compartment model. In these sheep 56 +/- 16% of the DTPA cleared from the lungs at a rate of 7.9 +/- 2.9%/min. The remainder cleared at a rate similar to that measured in the sheep ventilated with zero end-expired pressure (0.35 +/- 0.18%/min). Additional control and lung inflation experiments were performed using /sup 99m/Tc-labeled human serum albumin (mol wt = 66,000, radius = 3.6 nm). In six control sheep ventilated with zero end-expired pressure the albumin clearance was best described by a one-compartment model with a clearance rate of 0.06 +/- 0.02%/min. The clearance rate in six sheep with increased lung volume was slightly larger (0.09 +/- 0.02, P less than 0.05) but was well described by a one-compartment model.

  16. Humanitarian IED clearance in Colombia

    NASA Astrophysics Data System (ADS)

    Hendrickx, J. M. H.; Molina, A.; Diaz, D.; Grasmueck, M.; Moreno, H. A.; Hernández, R. D.

    2008-04-01

    The development of Improvised Explosive Devices (IED's) by insurgents in Colombia is characterized by a quick response to counter IED measures. Many current IED's do not contain any metal parts and can have any shape or form. Due to the low metal content or the absence of any metal parts, sensors based on metal detection are not useful anymore. Due to the wide variety of sizes, shapes, and enclosure materials of current IED's, one and two-dimensional GPR sensors using a "library" of known shapes as well as acoustic sensors using material characteristic frequencies have become ineffective. Therefore, the Colombian experience strongly suggests that chemical sensors are the way for IED detection in soils since they do not depend on IED metal content, size, or shape but only on the presence of explosives, a necessary ingredient for any IED. Promising recently developed chemical sensors make use of semiconducting organic polymers (SOPs) such as FIDO and laser-induced breakdown spectroscopy (LIBS). Once an explosive has been detected, the IED needs to be identified and located. Therefore, there is a need for three-dimensional high resolution scans for identification of all subsoil features including rocks, roots, and IED's. The recently developed 3D-GPR (Ground Penetrating Radar) can map all features of the subsoil with a spatial resolution of about 2 cm or less. The objectives of this contribution are to inform about the IED problem in Colombia and how novel technologies may contribute to humanitarian IED clearance under humid tropical conditions.

  17. Advanced optical blade tip clearance measurement system

    NASA Technical Reports Server (NTRS)

    Ford, M. J.; Honeycutt, R. E.; Nordlund, R. E.; Robinson, W. W.

    1978-01-01

    An advanced electro-optical system was developed to measure single blade tip clearances and average blade tip clearances between a rotor and its gas path seal in an operating gas turbine engine. This system is applicable to fan, compressor, and turbine blade tip clearance measurement requirements, and the system probe is particularly suitable for operation in the extreme turbine environment. A study of optical properties of blade tips was conducted to establish measurement system application limitations. A series of laboratory tests was conducted to determine the measurement system's operational performance characteristics and to demonstrate system capability under simulated operating gas turbine environmental conditions. Operational and environmental performance test data are presented.

  18. Plasma Creatinine Clearance in the Dog

    ERIC Educational Resources Information Center

    Frazier, Loy W.

    1977-01-01

    Lists materials and methods for an experiment that demonstrates the concept of glomerular filtration rate (GFR) using anesthesized dogs. In the dog, GFR is equivalent to the renal plasma clearance of exogenous creatinine. (CS)

  19. 33 CFR 117.47 - Clearance gauges.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 117.47 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY BRIDGES DRAWBRIDGE... specify otherwise for particular drawbridges, clearance gauges shall be designed, installed, and... appropriate bridge....

  20. 49 CFR 192.325 - Underground clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... installed with enough clearance from any other underground structure to allow proper maintenance and to... prevent the heat from impairing the serviceability of the pipe. (d) Each pipe-type or bottle-type...

  1. Compressor airfoil tip clearance optimization system

    DOEpatents

    Little, David A.; Pu, Zhengxiang

    2015-08-18

    A compressor airfoil tip clearance optimization system for reducing a gap between a tip of a compressor airfoil and a radially adjacent component of a turbine engine is disclosed. The turbine engine may include ID and OD flowpath boundaries configured to minimize compressor airfoil tip clearances during turbine engine operation in cooperation with one or more clearance reduction systems that are configured to move the rotor assembly axially to reduce tip clearance. The configurations of the ID and OD flowpath boundaries enhance the effectiveness of the axial movement of the rotor assembly, which includes movement of the ID flowpath boundary. During operation of the turbine engine, the rotor assembly may be moved axially to increase the efficiency of the turbine engine.

  2. Voltage-clearance recommendations for printed boards

    SciTech Connect

    Jennings, C W; Cave, G; Evans, A; Harrington, D J; Kirchenbaum, J; Martz, R E; Mierendorf, R C; Smith, G A

    1980-01-01

    Present and future trends in printed board designs point to higher circuit densities with narrower lines and closer spacings. Some designers are now laying out boards with 0.13 mm lines and spacings. The reduction of nominal spacing between conductive elements has raised questions concerning the adequacy of present voltage-clearance recommendations. The present recommendations are considered too conservative in that they are weighted with large safety factors, especially for small clearances, and are frequently disregarded by many designers. Published voltage breakdown measurements made on printed boards with comb patterns with their enhanced conductor test lengths show breakdowns occurring at much higher voltages than those specified for the clearances in existing documents. A Task Group was set up to review published breakdown measurements and to make any additional measurements necessary to provide voltage-clearance recommendations. These recommendations are reported.

  3. Controls Considerations for Turbine Active Clearance Control

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.

    2004-01-01

    This presentation discusses active control of turbine tip clearance from a control systems perspective. It is a subset of charts that were presented at the 2003 meeting of the International Society of Air Breathing Engines which was held August 31 through September 5 in Cleveland, Ohio. The associated reference paper is cited at the end of the presentation. The presentation describes active tip clearance control research being conducted by NASA to improve turbine engine systems. The target application for this effort is commercial aircraft engines. However, it is believed that the technologies developed as part of this research will benefit a broad spectrum of current and future turbomachinery. The first part of the presentation discusses the concept of tip clearance, problems associated with it, and the benefits of controlling it. It lays out a framework for implementing tip clearance controls that enables the implementation to progress from purely analytical to hardware-in-the-loop to fully experimental. And it briefly discusses how the technologies developed will be married to the previously described ACC Test Rig for hardware-in-the-loop demonstrations. The final portion of the presentation, describes one of the key technologies in some detail by presenting equations and results for a functional dynamic model of the tip clearance phenomena. As shown, the model exhibits many of the clearance dynamics found in commercial gas turbine engines. However, initial attempts to validate the model identified limitations that are being addressed to make the model more realistic.

  4. Clearance of Tc-99m DTPA aerosol from coal miners' lungs

    SciTech Connect

    Susskind, H.; Brill, A.B.; Harold, W.H.

    1985-07-01

    Alterations in regional epithelial permeability were assessed in 22 retired West Virginia coal miners' lungs by measuring the clearance of inhaled 0.5-..mu..m Tc-99m DTPA aerosol. Activity was measured in both lungs and in regions of interest placed over the lung periphery in the apical, middle, and basal portions of each lung. Clearance rates (T/sub 1/2/) for 5 nonsmokers, 8 ex-smokers, and 9 smokers were significantly faster than for comparable subjects measured elsewhere, who were not coal miners. Regional apex-to-base distributions of DTPA were measured as a function of clearance time and compared with regional ventilation and perfusion. Regional, as well as overall lung clearance curves of 8 smokers and 4 ex-smokers had two components, with overall T/sub 1/2/ of <7 min for the faster one. No correlations were found between T/sub 1/2/ and DLCO or with P(A-a)O/sub 2/. The results of our study suggest that measurement of DTPA clearance is a potentially useful noninvasive technique to assess lung injury in miners exposed to coal dust. 14 refs., 6 figs., 2 tabs.

  5. A deep sequencing tool for partitioning clearance rates following antimalarial treatment in polyclonal infections

    PubMed Central

    Mideo, Nicole; Bailey, Jeffrey A.; Hathaway, Nicholas J.; Ngasala, Billy; Saunders, David L.; Lon, Chanthap; Kharabora, Oksana; Jamnik, Andrew; Balasubramanian, Sujata; Björkman, Anders; Mårtensson, Andreas; Meshnick, Steven R.; Read, Andrew F.; Juliano, Jonathan J.

    2016-01-01

    Background and objectives: Current tools struggle to detect drug-resistant malaria parasites when infections contain multiple parasite clones, which is the norm in high transmission settings in Africa. Our aim was to develop and apply an approach for detecting resistance that overcomes the challenges of polyclonal infections without requiring a genetic marker for resistance. Methodology: Clinical samples from patients treated with artemisinin combination therapy were collected from Tanzania and Cambodia. By deeply sequencing a hypervariable locus, we quantified the relative abundance of parasite subpopulations (defined by haplotypes of that locus) within infections and revealed evolutionary dynamics during treatment. Slow clearance is a phenotypic, clinical marker of artemisinin resistance; we analyzed variation in clearance rates within infections by fitting parasite clearance curves to subpopulation data. Results: In Tanzania, we found substantial variation in clearance rates within individual patients. Some parasite subpopulations cleared as slowly as resistant parasites observed in Cambodia. We evaluated possible explanations for these data, including resistance to drugs. Assuming slow clearance was a stable phenotype of subpopulations, simulations predicted that modest increases in their frequency could substantially increase time to cure. Conclusions and implications: By characterizing parasite subpopulations within patients, our method can detect rare, slow clearing parasites in vivo whose phenotypic effects would otherwise be masked. Since our approach can be applied to polyclonal infections even when the genetics underlying resistance are unknown, it could aid in monitoring the emergence of artemisinin resistance. Our application to Tanzanian samples uncovers rare subpopulations with worrying phenotypes for closer examination. PMID:26817485

  6. 48 CFR 801.602-76 - Business clearance review.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Business clearance review... Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a... obtain a business clearance review prior to award of any contract, task or delivery order, or...

  7. 48 CFR 801.602-76 - Business clearance review.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Business clearance review... Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a... obtain a business clearance review prior to award of any contract, task or delivery order, or...

  8. 48 CFR 801.602-76 - Business clearance review.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Business clearance review... Authority, and Responsibilities 801.602-76 Business clearance review. (a) A business clearance review is a... obtain a business clearance review prior to award of any contract, task or delivery order, or...

  9. 48 CFR 945.603-70 - Plant clearance function.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Plant clearance function... Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the contracting officer shall assume all responsibilities of the plant clearance...

  10. 48 CFR 945.603-70 - Plant clearance function.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Plant clearance function... Plant clearance function. If the plant clearance function has not been formally delegated to another Federal agency, the contracting officer shall assume all responsibilities of the plant clearance...

  11. 31 CFR 205.20 - What is a clearance pattern?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 31 Money and Finance: Treasury 2 2010-07-01 2010-07-01 false What is a clearance pattern? 205.20... Agreement § 205.20 What is a clearance pattern? States use clearance patterns to project when funds are paid... is applied. (c) A clearance pattern must include seasonal or other periodic variations in...

  12. Atorvastatin delays the glucose clearance rate in hypercholesterolemic rabbits.

    PubMed

    Cheng, Daxin; Wang, Yanli; Gao, Shoucui; Wang, Xiaojing; Sun, Wentao; Bai, Liang; Cheng, Gong; Chu, Yonglie; Zhao, Sihai; Liu, Enqi

    2015-05-01

    The administration of statin might increase the risk of new-onset diabetes in hypercholesterolemic patients based on the recent clinical evidence. However, the causal relationship must be clarified and confirmed in animal experiments. Therefore, we mimicked hypercholesterolemia by feeding rabbits a high-cholesterol diet (HCD) and performed 16 weeks of atorvastatin administration to investigate the effect of statin on glucose metabolism. The intravenous glucose tolerance test showed that plasma glucose levels in the statin-treated rabbits were consistently higher and that there was a slower rate of glucose clearance from the blood than in HCD rabbits. The incremental area under the curve for glucose in the statin-treated rabbits was also significantly larger than in the HCD rabbits. However, there was no significant difference between the two groups in the intravenous insulin tolerance test. The glucose-lowering ability of exogenous insulin was not impaired by statin treatment in hypercholesterolemic rabbits. The administration of a single dose of statin did not affect glucose metabolism in normal rabbits. The statin also significantly increased the levels of high-density lipoprotein cholesterol, alanine aminotransferase and aspartate transaminase and decreased plasma levels of total cholesterol, triglycerides and low-density lipoprotein cholesterol in the hypercholesterolemic rabbits, whereas it did not affect plasma levels of glucose and insulin. The current results showed that atorvastatin treatment resulted in a significant delay of glucose clearance in hypercholesterolemic rabbits, and this rabbit model could be suitable for studying the effects of statin on glucose metabolism.

  13. Lower metabolic clearance of tizanidine in Japanese subjects.

    PubMed

    Momo, Kenji; Homma, Masato; Kohda, Yukinao

    2013-12-01

    Our aim was to determine whether metabolic clearance, renal clearance, or both elimination pathways contribute to ethnic differences in tizanidine clearance, which is ~ 2-fold higher in Caucasians than in Asians. The pharmacokinetic parameters of tizanidine in 9 healthy male Japanese subjects were compared with those of Caucasians in previous studies. Metabolic clearance of tizanidine was lower in Japanese than in Caucasian subjects (5.9 vs. 8.1 - 10.9 l/h/kg), although renal clearances were similar (0.040 vs. 0.047 - 0.055 l/h/kg). The results suggest that ethnic differences in tizanidine clearance are due to differences in metabolic clearance.

  14. 75 FR 38959 - Lead; Clearance and Clearance Testing Requirements for the Renovation, Repair, and Painting...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-07

    ... established in the Federal Register of May 6, 2010 (75 FR 25038) (FRL-8823-5). In that document, EPA proposed... AGENCY 40 CFR Part 745 RIN 2070-AJ57 Lead; Clearance and Clearance Testing Requirements for the... Federal Register of May 6, 2010, concerning several revisions to the 2008 Lead Renovation, Repair,...

  15. Extreme contagion in global habitat clearance.

    PubMed

    Boakes, Elizabeth H; Mace, Georgina M; McGowan, Philip J K; Fuller, Richard A

    2010-04-01

    Habitat clearance remains the major cause of biodiversity loss, with consequences for ecosystem services and for people. In response to this, many global conservation schemes direct funds to regions with high rates of recent habitat destruction, though some also emphasize the conservation of remaining large tracts of intact habitat. If the pattern of habitat clearance is highly contagious, the latter approach will help prevent destructive processes gaining a foothold in areas of contiguous intact habitat. Here, we test the strength of spatial contagion in the pattern of habitat clearance. Using a global dataset of land-cover change at 50 x 50 km resolution, we discover that intact habitat areas in grid cells are refractory to clearance only when all neighbouring cells are also intact. The likelihood of loss increases dramatically as soon as habitat is cleared in just one neighbouring cell, and remains high thereafter. This effect is consistent for forests and grassland, across biogeographic realms and over centuries, constituting a coherent global pattern. Our results show that landscapes become vulnerable to wholesale clearance as soon as threatening processes begin to penetrate, so actions to prevent any incursions into large, intact blocks of natural habitat are key to their long-term persistence.

  16. Colchicine clearance is impaired in alcoholic cirrhosis.

    PubMed

    Leighton, J A; Bay, M K; Maldonado, A L; Schenker, S; Speeg, K V

    1991-12-01

    Colchicine may have benefit in primary biliary cirrhosis and alcoholic liver disease. It is currently used in patients with impaired liver function, yet little is known about its elimination in such patients. Colchicine clearance in the rat is significantly impaired in various models of liver disease. To study this in human beings, colchicine pharmacokinetics were compared in normal subjects and patients with alcoholic cirrhosis. Colchicine clearance was impaired in the cirrhotic patients. Normal subjects had a mean clearance of 10.65 +/- 1.82 ml/min.kg, whereas cirrhotic patients had a mean clearance of 4.22 +/- 0.45 ml/min.kg (p less than 0.01). The half-life was 57.4 +/- 14.2 min in control subjects vs. 114.4 +/- 19.7 min in cirrhotic patients (p = 0.054). Volume of distribution was not different in the two groups (0.718 +/- 0.1 L/kg in control subjects; 0.716 +/- 0.158 L/kg in cirrhotic patients, p greater than 0.99). No correlation was seen between colchicine clearance and bilirubin, albumin, prothrombin time or Child-Pugh classification, but this may be the result of the small number of patients studied. Based on the values measured, it is estimated that colchicine steady state would change from an average 1.12 ng/ml in normal individuals to 2.82 ng/ml in the cirrhotic patients if 0.6 mg were taken every 12 hr. It is unknown whether this change would be clinically significant. These data show that cirrhosis impairs colchicine clearance and demonstrates that the liver is a major route of colchicine elimination.

  17. Active clearance control system for a turbomachine

    NASA Technical Reports Server (NTRS)

    Johnston, R. P.; Knapp, M. H.; Coulson, C. E. (Inventor)

    1982-01-01

    An axial compressor is provided with a cooling air manifold surrounding a portion of the shroud, and means for bleeding air from the compressor to the manifold for selectively flowing it in a modulating manner axially along the outer side of the stator/shroud to cool and shrink it during steady state operating conditions so as to obtain minimum shroud/rotor clearance conditions. Provision is also made to selectively divert the flow of cooling air from the manifold during transient periods of operation so as to alter the thermal growth or shrink rate of the stator/shroud and result in adequate clearance with the compressor rotor.

  18. Pharmacologic agents for mucus clearance in bronchiectasis.

    PubMed

    Nair, Girish B; Ilowite, Jonathan S

    2012-06-01

    There are no approved pharmacologic agents to enhance mucus clearance in non-cystic fibrosis (CF) bronchiectasis. Evidence supports the use of hyperosmolar agents in CF, and studies with inhaled mannitol and hypertonic saline are ongoing in bronchiectasis. N-acetylcysteine may act more as an antioxidant than a mucolytic in other lung diseases. Dornase α is beneficial to patients with CF, but is not useful in patients with non-CF bronchiectasis. Mucokinetic agents such as β-agonists have the potential to improve mucociliary clearance in normals and many disease states, but have not been adequately studied in patients with bronchiectasis. PMID:22640851

  19. Pharmacologic agents for mucus clearance in bronchiectasis.

    PubMed

    Nair, Girish B; Ilowite, Jonathan S

    2012-06-01

    There are no approved pharmacologic agents to enhance mucus clearance in non-cystic fibrosis (CF) bronchiectasis. Evidence supports the use of hyperosmolar agents in CF, and studies with inhaled mannitol and hypertonic saline are ongoing in bronchiectasis. N-acetylcysteine may act more as an antioxidant than a mucolytic in other lung diseases. Dornase α is beneficial to patients with CF, but is not useful in patients with non-CF bronchiectasis. Mucokinetic agents such as β-agonists have the potential to improve mucociliary clearance in normals and many disease states, but have not been adequately studied in patients with bronchiectasis.

  20. Prediction of hepatic microsomal intrinsic clearance and human clearance values for drugs.

    PubMed

    Nikolic, Katarina; Agababa, Danica

    2009-10-01

    Twenty-nine drugs of different structures were used in theoretical QSAR analysis of human hepatic microsomal intrinsic clearance (in vitro T(1/2) and in vitro CL'(int)) and whole body clearance (CL(blood)). The examined compounds demonstrated a wide range of scaled intrinsic clearance values. Constitutional, geometrical, physico-chemical and electronic descriptors were computed for the examined structures by use of the Marvin Sketch 5.1.3_2, the Chem3D Ultra 7.0.0 and the Dragon 5.4 program. Partial least squares regression (PLSR), has been applied for selection of the most relevant molecular descriptors and development of quantitative structure-activity relationship (QSAR) model for human hepatic microsomal intrinsic clearance (in vitro T(1/2)). Optimal QSAR models with nine and ten variables, R(2)>0.808 and cross-validation parameter q(pre)(2)>0.623, were selected and compared. Since the microsomal in vitro T(1/2) data can be used for calculation of in vitro CL'(int) and in vivo CL(blood), the developed QSAR model will enable one to analyze the kinetics of cytochrome P450-mediated reactions in term of intrinsic clearance and whole body clearance. A comparison is made between predictions produced from the QSAR analysis and experimental data, and there appears to be generally satisfactory correlations with the literature values for intrinsic clearance data. PMID:19713138

  1. Clinical evaluation of amylase-creatinine clearance ratio and amylase isoenzyme clearance in chronic renal failure.

    PubMed

    Maeda, M; Otsuki, M; Okano, K; Yamasaki, T; Baba, S

    1981-01-01

    Amylase-creatinine clearance ratio (ACCR) and amylase isoenzyme clearance were determined simultaneously in patients with chronic renal failure. ACCR in patients with compensated renal failure (3.5 +/- 0.4%) was not significantly different from normals (2.6 +/- 0.2%), while that in patients with non-compensated renal failure (6.7 +/- 0.4%) was significantly higher than that in normals. Clearance ratio of pancreatic isoamylase (Amylase-1) relative to creatinine clearance (CAmy . 1/Ccr) in patients with both compensated (5.9 +/- 1.0%) and non-compensated (6.8 +/- 0.4%) renal failure was as high as that in patients with acute pancreatitis (6.6 +/- 0.5%). On the other hand, clearance ratio of salivary isoamylase (Amylase-3) relative to creatinine clearance (CAmy . 3/CCr) in patients with compensated renal failure (1.5 +/- 0.3%) was almost the same as that in normals (2.1 +/- 0.1%), while that in patients with non-compensated renal failure was 5.9 +/- 0.7%, which was significantly higher than that in normals. The present study revealed that elevated ACCR in patients with severely impaired renal function was due to the increase of the clearance ratio for both pancreatic and salivary amylase. These facts suggested that glomerular permeability and tubular reabsorption for pancreatic and salivary amylase might play an important role on ACCR in patients with severely impaired renal function.

  2. Clinical evaluation of amylase-creatinine clearance ratio and amylase isoenzyme clearance in chronic renal failure.

    PubMed

    Maeda, M; Otsuki, M; Okano, K; Yamasaki, T; Baba, S

    1981-01-01

    Amylase-creatinine clearance ratio (ACCR) and amylase isoenzyme clearance were determined simultaneously in patients with chronic renal failure. ACCR in patients with compensated renal failure (3.5 +/- 0.4%) was not significantly different from normals (2.6 +/- 0.2%), while that in patients with non-compensated renal failure (6.7 +/- 0.4%) was significantly higher than that in normals. Clearance ratio of pancreatic isoamylase (Amylase-1) relative to creatinine clearance (CAmy . 1/Ccr) in patients with both compensated (5.9 +/- 1.0%) and non-compensated (6.8 +/- 0.4%) renal failure was as high as that in patients with acute pancreatitis (6.6 +/- 0.5%). On the other hand, clearance ratio of salivary isoamylase (Amylase-3) relative to creatinine clearance (CAmy . 3/CCr) in patients with compensated renal failure (1.5 +/- 0.3%) was almost the same as that in normals (2.1 +/- 0.1%), while that in patients with non-compensated renal failure was 5.9 +/- 0.7%, which was significantly higher than that in normals. The present study revealed that elevated ACCR in patients with severely impaired renal function was due to the increase of the clearance ratio for both pancreatic and salivary amylase. These facts suggested that glomerular permeability and tubular reabsorption for pancreatic and salivary amylase might play an important role on ACCR in patients with severely impaired renal function. PMID:6167484

  3. 32 CFR 154.16 - Security clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... shall be accomplished in accordance with 32 CFR part 159. The investigative requirement shall be the... be processed for a security clearance in accordance with 32 CFR part 353 and the provisions of this...); where the full investigative coverage cannot be completed, a counterintelligence scope...

  4. 24 CFR 35.1340 - Clearance.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... abatement of lead-based paint or lead-based paint hazards shall be performed in accordance with 40 CFR 745... the steps set forth at 40 CFR 745.227(e)(8). If clearance is being performed after lead-based...

  5. 24 CFR 35.1340 - Clearance.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... abatement of lead-based paint or lead-based paint hazards shall be performed in accordance with 40 CFR 745... the steps set forth at 40 CFR 745.227(e)(8). If clearance is being performed after lead-based...

  6. 24 CFR 35.1340 - Clearance.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... abatement of lead-based paint or lead-based paint hazards shall be performed in accordance with 40 CFR 745... the steps set forth at 40 CFR 745.227(e)(8). If clearance is being performed after lead-based...

  7. 24 CFR 35.1340 - Clearance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...-BASED PAINT POISONING PREVENTION IN CERTAIN RESIDENTIAL STRUCTURES Methods and Standards for Lead-Paint... abatement of lead-based paint or lead-based paint hazards shall be performed in accordance with 40 CFR 745... the steps set forth at 40 CFR 745.227(e)(8). If clearance is being performed after lead-based...

  8. 32 CFR 154.48 - Issuing clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., separated from DoD civilian employment, has no further official relationship with DoD, official action has... individual's relationship with DoD exists greater than 24 months and/or, the need for regular access to... Component may issue an interim clearance to personnel under their administrative jurisdiction pending...

  9. Waste Segregation Based on Derived Clearance Levels

    SciTech Connect

    Garisto, N.C.; Parhizgari, Z.

    2008-07-01

    This paper describes the methodology and results of a radiological modeling in support of an application to release very low level radiologically contaminated waste from regulatory control and allow its haulage and disposal in a hazardous waste landfill. The Canadian regulatory body responsible for licensing operations involving nuclear materials (the Canadian Nuclear Safety Commission), has not yet formally defined clearance levels for free release of low level radiologically contaminated waste. The IAEA clearance levels have been derived for certain situations and receptor characteristics, which might be too conservative for an actual case. A site-specific pathways analysis was therefore completed to define conditional clearance levels using the concept of de minimis dose limit. Derived Conditional Clearance Levels were calculated for each radionuclide based on the maximally exposed hypothetical individuals to determine whether each waste stream can be 'cleared' from regulatory controls. The results showed that haulage of the waste from the station to the haulage/processing facility and transportation of waste or sludge from the haulage/processing facility to the disposal facility, handling of the waste or sludge at the haulage/processing facility, and incineration and/or disposal of waste or sludge at the disposal facility would not expose the workers to doses above 0.1 {mu}Sv/yr., which is less than the de minimis dose limit of 10 {mu}Sv/yr. (authors)

  10. Mediators and mucociliary clearance in asthma.

    PubMed

    Pavia, D; Lopez-Vidriero, M T; Clarke, S W

    1987-01-01

    Lung mucociliary clearance is significantly reduced in asthmatic patients compared to healthy controls even during clinical remission. Further retardation in mucous clearance occurs during sleep per se and this may be a contributing factor to nocturnal asthma. Chemical mediators of anaphylaxis appear to have various and, sometimes opposing effects on the two essential components for mucociliary clearance, namely cilia and mucus. Some mediators such as leukotrienes C4 and D4 are potent secretagogues and histamine increases the water flux into the lumen of the airways from the mucosa. Slow-reacting substance of anaphylaxis (SRS-A) reduces mucus transport whereas histamine enhances it. Ciliostimulation has been reported following allergen challenge and this contrasts with the cilioinhibitory effect of asthmatics' sputa. It appears however, that the net effect of the various chemicals of anaphylaxis is one of impairment of mucus clearance. Some pharmacological agents, used for the relief of bronchospasm and control of asthma, also stimulate mucociliary transport, a desirable additional effect. PMID:3311245

  11. 32 CFR 154.16 - Security clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... shall be accomplished in accordance with 32 CFR part 159. The investigative requirement shall be the... be processed for a security clearance in accordance with 32 CFR part 353 and the provisions of this... cleared personnel. (7) To food service personnel, vendors and similar commercial sales or...

  12. 15 CFR 752.15 - Export clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... accordance with requirements of the Foreign Trade Statistics Regulations (15 CFR part 30) and § 758.1 of the... 15 Commerce and Foreign Trade 2 2010-01-01 2010-01-01 false Export clearance. 752.15 Section 752... OF INDUSTRY AND SECURITY, DEPARTMENT OF COMMERCE EXPORT ADMINISTRATION REGULATIONS...

  13. The Skipping Rope Curve

    ERIC Educational Resources Information Center

    Nordmark, Arne; Essen, Hanno

    2007-01-01

    The equilibrium of a flexible inextensible string, or chain, in the centrifugal force field of a rotating reference frame is investigated. It is assumed that the end points are fixed on the rotation axis. The shape of the curve, the skipping rope curve or "troposkien", is given by the Jacobi elliptic function sn. (Contains 3 figures.)

  14. Anodic Polarization Curves Revisited

    ERIC Educational Resources Information Center

    Liu, Yue; Drew, Michael G. B.; Liu, Ying; Liu, Lin

    2013-01-01

    An experiment published in this "Journal" has been revisited and it is found that the curve pattern of the anodic polarization curve for iron repeats itself successively when the potential scan is repeated. It is surprising that this observation has not been reported previously in the literature because it immediately brings into…

  15. Hepatectomy Based on Future Liver Remnant Plasma Clearance Rate of Indocyanine Green.

    PubMed

    Uchida, Yuichiro; Furuyama, Hiroaki; Yasukawa, Daiki; Nishino, Hiroto; Ando, Yasuhisa; Hata, Toshiyuki; Machimoto, Takafumi; Yoshimura, Tsunehiro

    2016-01-01

    Background. Hepatectomy, an important treatment modality for liver malignancies, has high perioperative morbidity and mortality rates. Safe, comprehensive criteria for selecting patients for hepatectomy are needed. Since June 2011, we have used a cut-off value of ≧ 0.05 for future liver remnant plasma clearance rate of indocyanine green as a criterion for hepatectomy. The aim of this study was to verify the validity of this criterion. Methods. From June 2011 to December 2015, 212 hepatectomies were performed in Tenri Yorozu Hospital. Of these 212 patients, 107 who underwent preoperative computed tomography imaging volumetry, indocyanine green clearance test, and hepatectomy (excluding partial resection or enucleation) were retrospectively analyzed. Results. There was no postoperative mortality. Posthepatectomy liver failure occurred in 59 patients (55.1%) (International Study Group of Liver Surgery Grade A: 43 cases (40.2%), Grade B: 16 cases (15.0%), and Grade C: no cases). Operative morbidity greater than Clavien-Dindo Grade 3 occurred in 23 patients (21.5%). A low future liver remnant plasma clearance rate of indocyanine green was a good predictor for Grade B cases (area under curve = 0.804; 95% confidence interval, 0.712-0.895). Conclusion. Liver remnant plasma clearance rate of indocyanine green is a valid criterion for hepatectomy.

  16. 19 CFR 122.26 - Entry and clearance.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... AIR COMMERCE REGULATIONS Private Aircraft § 122.26 Entry and clearance. Private aircraft, as defined... information as set forth in § 122.22(c), and grants electronic clearance via electronic mail or telephone....

  17. 75 FR 70341 - Agency Information Collection Activities: Emergency Clearance Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-11-17

    ... From the Federal Register Online via the Government Publishing Office SOCIAL SECURITY ADMINISTRATION Agency Information Collection Activities: Emergency Clearance Request The Social Security..._Submission@omb.eop.gov . (SSA), Social Security Administration, DCBFM, Attn: Reports Clearance Officer,...

  18. 10 CFR 95.17 - Processing facility clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL... of the Facility Clearance would not be inconsistent with the national interest, including a finding... concerning the foreign intelligence threat, risk of unauthorized technology transfer, type and sensitivity...

  19. 10 CFR 95.17 - Processing facility clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL... of the Facility Clearance would not be inconsistent with the national interest, including a finding... concerning the foreign intelligence threat, risk of unauthorized technology transfer, type and sensitivity...

  20. 10 CFR 95.17 - Processing facility clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL... of the Facility Clearance would not be inconsistent with the national interest, including a finding... concerning the foreign intelligence threat, risk of unauthorized technology transfer, type and sensitivity...

  1. WWW-based data entry for document clearance requests

    SciTech Connect

    Stasiak, D.M.

    1997-10-08

    All documents created at Argonne must be cleared before being published. The clearance process is coordinated by the Publications and Record Services. The Electronic Document Review and Clearance System (EDRC) consists of a Web-based system for submission of clearance requests, an electronic staging area for document awaiting review, and Web-based review and clearance of documents. This report covers the document clearing process, the EDRC system, expected benefits/costs, and a demonstration.

  2. Evaluation of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Lattime, Scott B.; Taylor, Shawn; DeCastro, Jonathan A.; Oswald, Jay; Melcher, Kevin J.

    2005-01-01

    Reducing blade tip clearances through active tip clearance control in the high pressure turbine can lead to significant reductions in emissions and specific fuel consumption as well as dramatic improvements in operating efficiency and increased service life. Current engines employ scheduled cooling of the outer case flanges to reduce high pressure turbine tip clearances during cruise conditions. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, reburst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). In an effort to improve upon current thermal methods, a first generation mechanically-actuated active clearance control (ACC) system has been designed and fabricated. The system utilizes independent actuators, a segmented shroud structure, and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. Ambient temperature performance tests of this first generation ACC system assessed individual seal component leakage rates and both static and dynamic overall system leakage rates. The ability of the nine electric stepper motors to control the position of the seal carriers in both open- and closed-loop control modes for single and multiple cycles was investigated. The ability of the system to follow simulated engine clearance transients in closed-loop mode showed the system was able to track clearances to within a tight tolerance ( 0.001 in. error).

  3. Evaluation of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Lattime, Scott B.; DeCastro, Jonathan A.; Oswald, Jay; Melcher, Kevin J.

    2005-01-01

    Reducing blade tip clearances through active tip clearance control in the high pressure turbine can lead to significant reductions in emissions and specific fuel consumption as well as dramatic improvements in operating efficiency and increased service life. Current engines employ scheduled cooling of the outer case flanges to reduce high pressure turbine tip clearances during cruise conditions. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, reburst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). In an effort to improve upon current thermal methods, a first generation mechanically-actuated active clearance control (ACC) system has been designed and fabricated. The system utilizes independent actuators, a segmented shroud structure, and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. Ambient temperature performance tests of this first generation ACC system assessed individual seal component leakage rates and both static and dynamic overall system leakage rates. The ability of the nine electric stepper motors to control the position of the seal carriers in both open- and closed-loop control modes for single and multiple cycles was investigated. The ability of the system to follow simulated engine clearance transients in closed-loop mode showed the system was able to track clearances to within a tight tolerance (0.001 in. error).

  4. 14 CFR 1260.63 - Customs clearance and visas.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 5 2010-01-01 2010-01-01 false Customs clearance and visas. 1260.63 Section 1260.63 Aeronautics and Space NATIONAL AERONAUTICS AND SPACE ADMINISTRATION GRANTS AND COOPERATIVE AGREEMENTS General Special Conditions § 1260.63 Customs clearance and visas. Customs Clearance and Visas...

  5. 30 CFR 57.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Clearance for surface equipment. 57.9330... Dumping Sites § 57.9330 Clearance for surface equipment. Continuous clearance of at least 30 inches from... tracks at all locations where possible or the area shall be marked conspicuously....

  6. 30 CFR 56.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Clearance for surface equipment. 56.9330... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Loading... Dumping Sites § 56.9330 Clearance for surface equipment. Continuous clearance of at least 30 inches...

  7. 30 CFR 56.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Clearance for surface equipment. 56.9330... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Loading... Dumping Sites § 56.9330 Clearance for surface equipment. Continuous clearance of at least 30 inches...

  8. 30 CFR 57.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Clearance for surface equipment. 57.9330... Dumping Sites § 57.9330 Clearance for surface equipment. Continuous clearance of at least 30 inches from... tracks at all locations where possible or the area shall be marked conspicuously....

  9. 30 CFR 56.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Clearance for surface equipment. 56.9330... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Loading... Dumping Sites § 56.9330 Clearance for surface equipment. Continuous clearance of at least 30 inches...

  10. 30 CFR 57.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Clearance for surface equipment. 57.9330... Dumping Sites § 57.9330 Clearance for surface equipment. Continuous clearance of at least 30 inches from... tracks at all locations where possible or the area shall be marked conspicuously....

  11. 46 CFR 56.75-10 - Joint clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 46 Shipping 2 2012-10-01 2012-10-01 false Joint clearance. 56.75-10 Section 56.75-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Brazing § 56.75-10 Joint clearance. (a) The clearance between surfaces to be joined shall be...

  12. 46 CFR 56.75-10 - Joint clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Joint clearance. 56.75-10 Section 56.75-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Brazing § 56.75-10 Joint clearance. (a) The clearance between surfaces to be joined shall be...

  13. 46 CFR 56.75-10 - Joint clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Joint clearance. 56.75-10 Section 56.75-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Brazing § 56.75-10 Joint clearance. (a) The clearance between surfaces to be joined shall be...

  14. 46 CFR 56.75-10 - Joint clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Joint clearance. 56.75-10 Section 56.75-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Brazing § 56.75-10 Joint clearance. (a) The clearance between surfaces to be joined shall be...

  15. 46 CFR 56.75-10 - Joint clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 46 Shipping 2 2013-10-01 2013-10-01 false Joint clearance. 56.75-10 Section 56.75-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) MARINE ENGINEERING PIPING SYSTEMS AND APPURTENANCES Brazing § 56.75-10 Joint clearance. (a) The clearance between surfaces to be joined shall be...

  16. Wear analysis of revolute joints with clearance in multibody systems

    NASA Astrophysics Data System (ADS)

    Bai, ZhengFeng; Zhao, Yang; Wang, XingGui

    2013-08-01

    In this work, the prediction of wear for revolute joint with clearance in multibody systems is investigated using a computational methodology. The contact model in clearance joint is established using a new hybrid nonlinear contact force model and the friction effect is considered by using a modified Coulomb friction model. The dynamics model of multibody system with clearance is established using dynamic segmentation modeling method and the computational process for wear analysis of clearance joint in multibody systems is presented. The main computational process for wear analysis of clearance joint includes two steps, which are dynamics analysis and wear analysis. The dynamics simulation of multibody system with revolute clearance joint is carried out and the contact forces are drawn and used to calculate the wear amount of revolute clearance joint based on the Archard's wear model. Finally, a four-bar multibody mechanical system with revolute clearance joint is used as numerical example application to perform the simulation and show the dynamics responses and wear characteristics of multibody systems with revolute clearance joint. The main results of this work indicate that the contact between the joint elements is wider and more frequent in some specific regions and the wear phenomenon is not regular around the joint surface, which causes the clearance size increase non-regularly after clearance joint wear. This work presents an effective method to predict wear of revolute joint with clearance in multibody systems.

  17. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 3 2014-10-01 2014-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case....

  18. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 3 2012-10-01 2012-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case....

  19. 48 CFR 945.670-1 - Plant clearance function.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... contracting officer shall assume all responsibilities of the plant clearance officer identified in 48 CFR 45... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Plant clearance function... MANAGEMENT GOVERNMENT PROPERTY Reporting, Reutilization, and Disposal 945.670-1 Plant clearance function....

  20. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 3 2013-10-01 2013-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case....

  1. 75 FR 37518 - Agency Information Collection Activities: Emergency Clearance Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-29

    ... ADMINISTRATION Agency Information Collection Activities: Emergency Clearance Request The Social Security...@ssa.gov . SSA submitted the information collection below to OMB for Emergency Clearance. SSA is requesting Emergency Clearance from OMB no later than July 6, 2010. Individuals can obtain copies of...

  2. 32 CFR 644.517 - Clearance of Army lands.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of Army lands. 644.517 Section 644.517 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL... and Improvements § 644.517 Clearance of Army lands. The responsibility for performing clearance...

  3. 32 CFR 644.517 - Clearance of Army lands.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Clearance of Army lands. 644.517 Section 644.517 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL... and Improvements § 644.517 Clearance of Army lands. The responsibility for performing clearance...

  4. 48 CFR 245.602-70 - Plant clearance procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 3 2011-10-01 2011-10-01 false Plant clearance procedures... Disposal 245.602-70 Plant clearance procedures. Follow the procedures at PGI 245.602-70 for establishing and processing a plant clearance case....

  5. 10 CFR 706.31 - Clearance of conciliators and arbitrators.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Clearance of conciliators and arbitrators. 706.31 Section... RELATIONS Contract Negotiation and Administration § 706.31 Clearance of conciliators and arbitrators. Conciliators and arbitrators who are regularly assigned to DOE cases may be processed for “Q” clearance at...

  6. 19 CFR 4.61 - Requirements for clearance.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 19 Customs Duties 1 2014-04-01 2014-04-01 false Requirements for clearance. 4.61 Section 4.61 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY VESSELS IN FOREIGN AND DOMESTIC TRADES Foreign Clearances § 4.61 Requirements for clearance....

  7. 7 CFR 1927.55 - Title clearance services.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 12 2010-01-01 2010-01-01 false Title clearance services. 1927.55 Section 1927.55... REGULATIONS TITLE CLEARANCE AND LOAN CLOSING Real Estate Title Clearance and Loan Closing § 1927.55 Title... borrower by a closing agent in connection with the transaction vary depending on whether a title...

  8. 32 CFR 644.69 - Title Clearance-Easements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Title Clearance-Easements. 644.69 Section 644.69... ESTATE HANDBOOK Acquisition Procurement of Title Evidence, Title Clearance, and Closings § 644.69 Title Clearance—Easements. (a) Easements Costing in Excess of $1,000. Curative action and clearance of title...

  9. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 24 Housing and Urban Development 5 2011-04-01 2011-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main...

  10. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 24 Housing and Urban Development 5 2010-04-01 2010-04-01 false Clearance under homes. 3285.305... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance under homes. A minimum clearance of 12 inches must be maintained between the lowest member of the main...

  11. 10 CFR 95.23 - Termination of facility clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 2 2010-01-01 2010-01-01 false Termination of facility clearance. 95.23 Section 95.23 Energy NUCLEAR REGULATORY COMMISSION (CONTINUED) FACILITY SECURITY CLEARANCE AND SAFEGUARDING OF NATIONAL SECURITY INFORMATION AND RESTRICTED DATA Physical Security § 95.23 Termination of facility clearance....

  12. 30 CFR 56.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Clearance for surface equipment. 56.9330... NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Loading... Dumping Sites § 56.9330 Clearance for surface equipment. Continuous clearance of at least 30 inches...

  13. 30 CFR 57.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Clearance for surface equipment. 57.9330 Section 57.9330 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND... Dumping Sites § 57.9330 Clearance for surface equipment. Continuous clearance of at least 30 inches...

  14. A curved vitrectomy probe.

    PubMed

    Chalam, K V; Shah, Vinay A; Tripathi, Ramesh C

    2004-01-01

    A curved vitrectomy probe for better accessibility of the peripheral retina in phakic eyes is described. The specially designed curved vitrectomy probe has a 20-gauge pneumatic cutter. The radius of curvature at the shaft is 19.4 mm and it is 25 mm long. The ora serrata is accessed through a 3.0- or 4.0-mm sclerotomy in phakic eyes without touching the crystalline lens. Use of this instrument avoids inadvertent trauma to the clear lens in phakic eyes requiring vitreous base excision. This curved vitrectomy instrument complements wide-angle viewing systems and endoscopes for safe surgical treatment of peripheral retinal pathology in phakic eyes. PMID:15185799

  15. Gas turbine engine active clearance control

    NASA Technical Reports Server (NTRS)

    Deveau, Paul J. (Inventor); Greenberg, Paul B. (Inventor); Paolillo, Roger E. (Inventor)

    1985-01-01

    Method for controlling the clearance between rotating and stationary components of a gas turbine engine are disclosed. Techniques for achieving close correspondence between the radial position of rotor blade tips and the circumscribing outer air seals are disclosed. In one embodiment turbine case temperature modifying air is provided in flow rate, pressure and temperature varied as a function of engine operating condition. The modifying air is scheduled from a modulating and mixing valve supplied with dual source compressor air. One source supplies relatively low pressure, low temperature air and the other source supplies relatively high pressure, high temperature air. After the air has been used for the active clearance control (cooling the high pressure turbine case) it is then used for cooling the structure that supports the outer air seal and other high pressure turbine component parts.

  16. Market Mechanism for Line Congestion Clearance

    NASA Astrophysics Data System (ADS)

    Ruiz Monroy, José Joaquín; Kita, Hiroyuki; Tanaka, Eiichi; Hasegawa, Jun

    This paper proposes a mechanism for clearance of line congestion and power flow control in a deregulated market environment. The mechanism applies penalties to the bilateral transactions that cause line congestion by increasing the prices of such transactions. The market regulates itself by redefining the transactions and checking again for violations, applying penalties if necessary and repeating the process until all the demand is satisfied without causing line congestion to the system. A bilateral transaction matrix (BTM) creation algorithm developed by the authors and a DC power flow program are integrated as parts of the market mechanism proposed in this paper. The congestion is cleared by the market participants when they reschedule their transactions. This mechanism is useful to study the effects of bilateral transactions on a power system and helps the Independent System Operator (ISO) to create rules and market mechanisms for line congestion clearance and power flow control.

  17. Airway clearance therapy: finding the evidence.

    PubMed

    Volsko, Teresa A

    2013-10-01

    Disease processes can impair ciliary function, alter secretion production and mucus rheology, and interfere with the cough reflex. Airway clearance therapy has been a cornerstone of therapy aimed at minimizing the devastating effects of airway obstruction, infection, and inflammation due to mucus stasis on the conducting airways and lung parenchyma. Although challenges to performing clinical studies evaluating the effectiveness of airway clearance therapeutic modalities exist, resources are available in the literature. In addition to device evaluations and original clinical research, the expert opinion, systematic reviews, and evidence-based practice guidelines can be found. These tools can be used to develop protocols and pathways to guide our practice. Monitoring and reporting patient, process, and financial outcomes are essential steps germane to the implementation of evidence-based care.

  18. Autophagy promotes DNA-protein crosslink clearance.

    PubMed

    Mu, Haibo; Liu, Qianjin; Niu, Hong; Wang, Dongdong; Tang, Jiangjiang; Duan, Jinyou

    2016-02-01

    Toxic DNA-protein crosslinks (DPCs) can result from exposure to radiation or chemotherapeutic agents. DPCs can also accumulate during aging or stress. However, the cellular mechanisms underlying clearance of DPCs remain largely unknown. Here, we have identified an important role of autophagy in the processing of DPCs induced by three representative agents: formaldehyde, a chemical used widely in industry; UV light; and camptothecin, a cytotoxic anticancer drug. Autophagy inhibitors, 3-methyladenine (3-MA) or chloroquine (CQ), promoted the accumulation of DPCs in damaged cells and injured organs. siRNA-mediated silencing of Atg5 or Atg7, two essential components for the formation of the autophagosome, gave similar results. In contrast, the autophagy inducer rapamycin (RAP) attenuated DPCs in vitro and in vivo. Our findings reveal the importance of autophagy in controlling the level of DPCs, and may open up a new avenue for understanding the formation and clearance of this detrimental DNA adduct. PMID:26921017

  19. Instrument for Measuring Engine Clearance Volumes

    NASA Technical Reports Server (NTRS)

    Sparrow, S W

    1920-01-01

    With the advent of the V type engine, a new method to measure the clearance volume in cylinders was needed. It was suggested that this measurement could be made by a process which consisted essentially of simultaneously changing both a known and unknown volume of gas by a known amount and then calculating the magnitude of the unknown from the resulting difference in pressure between the two. An instrument based on this design is described.

  20. Deposition and clearance of inhaled particles.

    PubMed Central

    Stuart, B O

    1976-01-01

    Theoretical models of respiratory tract deposition of inhaled particles are compared to experimental studies of deposition patterns in humans and animals, as determined principally by particle size, density, respiratory rate and flow parameters. Various models of inhaled particle deposition make use of convenient approximations of the respiratory tract to predict tractional deposition according to fundamental physical processes of impaction, sedimentation, and diffusion. These theoretical models for both total deposition and regional (nasopharyngeal, tracheobronchial, and pulmonary) deposition are compared with experimental studies of inhaled dusts in humans or experimental animals that have been performed in many laboratories over several decades. Reasonable correlation has been obtained between theoretical and experimental studies, but the behavior of very fine (less than 0.01 mum) particles requires further refinement.Properties of particle shape, charge, and hygroscopicity as well as the degree of respiratory tract pathology also influence deposition patterns and further experimental work is urgently needed in these areas. The influence upon deposition patterns of dynamic alterations in inspiratory flow profiles caused by a variety of breathing patterns also requires further study, and the use of such techniques with selected inhaled particle size holds promise in possible diagnostic aid in diagnosis of normal versus disease conditions. Mechanisms of conducting airway and alveolar clearance processes involving mucociliary clearance, dissolution, transport to systemic circulation, and translocation via regional lymphatic clearance are discussed. The roles of the pulmonary macrophage in airway and alveolar clearance are described, and the applicability of recent solubility models for translocation or deposited materials to liver, skeleton, or other systemic organs is discussed. PMID:797567

  1. Similarity analysis of compressor tip clearance flow structure

    NASA Technical Reports Server (NTRS)

    Chen, G. T.; Greitzer, E. M.; Tan, C. S.; Marble, F. E.

    1991-01-01

    A new approach is presented for analyzing compressor tip clearance flow. The basic idea is that the clearance velocity field can be (approximately) decomposed into independent throughflow and crossflow, since chordwise pressure gradients are much smaller than normal pressure gradients in the clearance region. As in the slender body approximation in external aerodynamics, this description implies that the three-dimensional steady clearance flow can be viewed as a two-dimensional, unsteady flow. Using this approach, a similarity scaling for the crossflow in the clearance region is developed and a generalized description of the clearance vortex is derived. Calculations based on the similarity scaling agree well with a wide range of experimental data in regard to flow features such as crossflow velocity field, static pressure field, and tip clearance vortex trajectory.

  2. Whole-body clearance kinetics and external dosimetry of 131I-3F8 monoclonal antibody for radioimmunotherapy of neuroblastoma.

    PubMed

    Dauer, Lawrence T; St Germain, Jean; Williamson, Matthew J; Zanzonico, Pat; Modak, Shakeel; Cheung, Nai-Kong; Divgi, Chaitanya

    2007-01-01

    The purpose of this retrospective study was to evaluate the whole-body clearance kinetics of I-3F8 monoclonal antibody, an anti-ganglioside 2 antibody, used in the treatment of pediatric patients with late-stage neuroblastoma (NB). Serial whole-body dose rate measurements were obtained on pediatric patients participating in phase I dose escalation studies of therapeutic I-3F8. Whole-body retention fractions were derived and fit for each treatment to exponential curves to determine both the effective half-lives and corresponding clearance fractions. 27 patients were administered I-3F8 over the course of cyclical administrations with a median administered activity of 2.5 GBq (range, 1-8.14 GBq), typically every 2-4 d for up to 9 treatment cycles. Based on whole-body dose rate measurements, there was a large variability in the calculated mono-exponential clearance effective half-life time, with a mean of 26.4 h (range, 12.4-45.5 h). The data from a subset of 12 treatments were fit to a bi-exponential curve with a rapid clearance component mean effective half-time of 16.9 h (range, 4.3-26 h) and a slower clearance component mean effective half-time of 65.5 h (range, 16.9-136 h). The use of whole-body dose rate measurements, obtained for patient-release and other radiation safety considerations, can be useful in estimating whole-body clearance kinetics for photon emitting radionuclide labeled mAbs and other therapeutic radiopharmaceuticals. In the case of I-3F8 for pediatric NB therapy, the demonstrated variability in effective half-time suggests the need for patient-specific tracer dosimetry for both optimization of treatment and radiation safety precaution decision-making.

  3. Deposition, retention, and clearance of inhaled particles.

    PubMed

    Lippmann, M; Yeates, D B; Albert, R E

    1980-11-01

    The relation between the concentrations and characteristics of air contaminants in the work place and the resultant toxic doses and potential hazards after their inhalation depends greatly on their patterns of deposition and the rates and pathways for their clearance from the deposition sites. The distribution of the deposition sites of inhaled particles is strongly dependent on their aerodynamic diameters. For normal man, inhaled non-hygroscopic particles greater than or equal to 2 micrometers that deposit in the conducting airways by impaction are concentrated on to a small fraction of the surface. Cigarette smoking and bronchitis produce a proximal shift in the deposition pattern. The major factor affecting the deposition of smaller particles is their transfer from tidal to reserve air. For particles soluble in respiratory tract fluid, systemic uptake may be relatively complete for all deposition patterns, and there may be local toxic or irritant effects or both. On the other hand, slowly soluble particles depositing in the conducting airways are carried on the surface to the glottis and are swallowed within one day. Mucociliary transport rates are highly variable, both along the ciliated airways of a given individual and between individuals. The changes in clearance rates produced by drugs, cigarette smoke, and other environmental pollutants can greatly increase or decrease these rates. Particles deposited in non-ciliated airways have large surface-to-volume ratios, and clearance by dissolution can occur for materials generally considered insoluble. They may also be cleared as free particles either by passive transport along surface liquids or, after phagocytosis, by transport within alveolar macrophages. If the particles penetrate the epithelium, either bare or within macrophages, they may be sequestered within cells or enter the lymphatic circulation and be carried to pleural, hilar, and more distant lymph nodes. Non-toxic insoluble particles are cleared from

  4. Deposition, retention, and clearance of inhaled particles.

    PubMed Central

    Lippmann, M; Yeates, D B; Albert, R E

    1980-01-01

    The relation between the concentrations and characteristics of air contaminants in the work place and the resultant toxic doses and potential hazards after their inhalation depends greatly on their patterns of deposition and the rates and pathways for their clearance from the deposition sites. The distribution of the deposition sites of inhaled particles is strongly dependent on their aerodynamic diameters. For normal man, inhaled non-hygroscopic particles greater than or equal to 2 micrometers that deposit in the conducting airways by impaction are concentrated on to a small fraction of the surface. Cigarette smoking and bronchitis produce a proximal shift in the deposition pattern. The major factor affecting the deposition of smaller particles is their transfer from tidal to reserve air. For particles soluble in respiratory tract fluid, systemic uptake may be relatively complete for all deposition patterns, and there may be local toxic or irritant effects or both. On the other hand, slowly soluble particles depositing in the conducting airways are carried on the surface to the glottis and are swallowed within one day. Mucociliary transport rates are highly variable, both along the ciliated airways of a given individual and between individuals. The changes in clearance rates produced by drugs, cigarette smoke, and other environmental pollutants can greatly increase or decrease these rates. Particles deposited in non-ciliated airways have large surface-to-volume ratios, and clearance by dissolution can occur for materials generally considered insoluble. They may also be cleared as free particles either by passive transport along surface liquids or, after phagocytosis, by transport within alveolar macrophages. If the particles penetrate the epithelium, either bare or within macrophages, they may be sequestered within cells or enter the lymphatic circulation and be carried to pleural, hilar, and more distant lymph nodes. Non-toxic insoluble particles are cleared from

  5. Study on Internal Flow and External Performance of a Semi-open Impeller Centrifugal Pump with Different Tip Clearances

    NASA Astrophysics Data System (ADS)

    Jia, Xiao-Qi; Cui, Bao-Ling; Zhang, Yu-Liang; Zhu, Zu-Chao

    2015-04-01

    To study the influence of tip clearance on internal flow characteristics and external performance of a prototype centrifugal pump with a semi-open impeller, the unsteady numerical simulation and performance experiments are carried out in this paper. The evolution process of leakage vortex with time t, the flow characteristics and the magnitude of leakage rate in tip clearance are obtained in details. The results indicate that the H-Q curve hump of centrifugal pump shows a weakened trend with the increasing of tip clearance Δc. Meanwhile, the leakage rate ΔQ and the ratio of leakage rate to discharge flow rate (ψ) gradually increase. At the same tip clearance, the leakage rate ΔQ increases, while the ratio of leakage rate to discharge flow rate (ψ) decreases with the increasing of discharge flow rate Q. It is found that higher volumetric loss account for a higher percentage of the total loss at small flow rate condition. There easily exist strong leakage vortexes in the impeller inlet, impeller passage and impeller outlet. The pressure difference between suction side and pressure side makes the fluid pass through the tip clearance layer to form a lower pressure region and leakage vortex.

  6. Preliminary application of dynamic pulmonary xenon-133 single-photon emission tomography in the evaluation of patients with pulmonary emphysema for thoracoscopic lung volume reduction surgery.

    PubMed

    Suga, K; Nishigauchi, K; Matsunaga, N; Matsumoto, T; Kume, N; Sugi, K; Esato, K

    1998-04-01

    Dynamic pulmonary xenon-133 single-photon emission tomography (SPET) with three-dimensional (3D) displays was preliminarily applied to select resection targets for thoracoscopic lung volume reduction surgery (LVRS) and to assess regional ventilatory changes following surgery. Dynamic SPET was performed using a triple-detector SPET system in 14 patients with pulmonary emphysema before and after LVRS. After reconstructing colour-illuminated, surface-rendered 3D images of equilibrium (EQ) and 3-min washout (WO3), a single 3D fusion display was created from these two different time-course image sets, in which the 3D WO3 image indicating 133Xe retention was visible through the overlying 3D EQ image delineating lung contours. Volumetric extent of retention on this display was quantified by a 133Xe retention index, defined as the ratio (%) of total pixel numbers of segmented 3-min WO data to those of EQ data. 133Xe SPET and appropriately thresholded 3D displays efficiently localized a total of 36 retention sites; 19 (52.7%) of these sites were not localized by CT because they were within the widely or homogeneously spreading non-bullous emphysematous lung tissues. The 3D displays enhanced the perception of anatomical configurations and the extent of 133Xe retention compared with multislice tomograms. Postoperatively, 3D fusion display visualized the details of regional changes in retention, and changes in the retention index on the 3D display with a standardized threshold correlated well with changes in 133Xe clearance time (T1/2) and %FEV1 (r = 0.881 and 0. 856, respectively; P<0.0001). This preliminary study indicates that 133Xe SPET and appropriately thresholded, topographic 3D displays are of potential use in selecting resection targets for LVRS, and in evaluating the treatment effects on regional ventilation.

  7. The sales learning curve.

    PubMed

    Leslie, Mark; Holloway, Charles A

    2006-01-01

    When a company launches a new product into a new market, the temptation is to immediately ramp up sales force capacity to gain customers as quickly as possible. But hiring a full sales force too early just causes the firm to burn through cash and fail to meet revenue expectations. Before it can sell an innovative product efficiently, the entire organization needs to learn how customers will acquire and use it, a process the authors call the sales learning curve. The concept of a learning curve is well understood in manufacturing. Employees transfer knowledge and experience back and forth between the production line and purchasing, manufacturing, engineering, planning, and operations. The sales learning curve unfolds similarly through the give-and-take between the company--marketing, sales, product support, and product development--and its customers. As customers adopt the product, the firm modifies both the offering and the processes associated with making and selling it. Progress along the manufacturing curve is measured by tracking cost per unit: The more a firm learns about the manufacturing process, the more efficient it becomes, and the lower the unit cost goes. Progress along the sales learning curve is measured in an analogous way: The more a company learns about the sales process, the more efficient it becomes at selling, and the higher the sales yield. As the sales yield increases, the sales learning process unfolds in three distinct phases--initiation, transition, and execution. Each phase requires a different size--and kind--of sales force and represents a different stage in a company's production, marketing, and sales strategies. Adjusting those strategies as the firm progresses along the sales learning curve allows managers to plan resource allocation more accurately, set appropriate expectations, avoid disastrous cash shortfalls, and reduce both the time and money required to turn a profit.

  8. [Ratio of amylase clearance and creatinine clearance in the diagnosis of acute pancreatitis].

    PubMed

    Haffter, D; Reichlin, B; Gyr, K

    1981-05-30

    In 21 healthy volunteers the ratio of amylase clearance and creatinine clearance (Cam/Ccr) was determined in urine collected at admission, after a 1-hour collection period and after a 2-hour collection period. The normal values were 1.8 +/- 1.6%, 1.9 +/- 2% and 2.0 +/- 1.7% respectively. They were comparable with those published by others. The reproducibility of the method was acceptable (r = 0.62). When compared with serum amylase determinations, Cam/Ccr showed neither better sensitivity in 19 patients suffering an acute episode of proven pancreatitis, nor better specificity in 19 patients with acute abdomen but no evidence of pancreatitis.

  9. Effects of passive smoking on theophylline clearance.

    PubMed

    Matsunga, S K; Plezia, P M; Karol, M D; Katz, M D; Camilli, A E; Benowitz, N L

    1989-10-01

    Theophylline disposition was examined in seven passive smokers, defined as nonsmokers with long-term exposure to cigarette smoke, and seven age-matched nonsmokers with minimal smoke exposure. Subjects were given an intravenous infusion of aminophylline (6 mg/kg) and blood samples were drawn before and during the 48-hour postinfusion period. Clearance for passive smokers was 6.01 x 10(-2) L/hr.kg and for nonsmokers, clearance was 4.09 x 10(-2) L/hr.kg (p less than 0.025). Terminal elimination half-life for passive smokers was 6.93 hours versus 8.69 hours for nonsmokers (p less than 0.05). The mean residence time for passive smokers was 9.89 hours. For nonsmokers, the mean residence time was 13.11 hours (p less than 0.05). These measurements were statistically different, whereas there was no difference in volume of distribution between the groups, suggesting that passive smokers metabolize theophylline more rapidly than nonsmokers. Plasma and urine cotinine and nicotine concentrations were measured in all subjects. There was a significant difference between the subject groups in plasma (p less than 0.004) and urine (p less than 0.002) cotinine concentrations. Theophylline clearance correlated with both plasma (r = 0.73, p less than 0.01) and urine (r = 0.79, p less than 0.01) cotinine concentrations. Additional studies should be conducted to further define the pharmacokinetic characteristics of passive smokers and to assess the effects of passive smoking on drugs metabolized by the mixed function oxidase system. PMID:2791443

  10. Lithium clearance in mineralocorticoid escape in humans

    SciTech Connect

    Boer, W.H.; Koomans, H.A.; Mees, E.J.D.

    1987-03-01

    Lithium clearance (C/sub Li/) has been advanced as an indicator of Na delivery from the proximal tubules. The authors studied C/sub Li/ in eight healthy males before and after mineralocorticoid escape, a maneuver that may induce suppression of fractional proximal Na reabsorption (FPR/sub Na/). FPR/sub Na/ was also estimated from changes in maximal free water clearance (C/sub H/sub 2/O/). Plasma volume was measured as the /sup 131/I-labeled albumin distribution space. Extracellular fluid volume was estimated as the /sup 82/Br vector distribution volume. According to the latter method, FPR/sub Na/ dropped whereas inulin clearance rose. The changes in C/sub Li/ were surprisingly large. If lithium is a valid marker of Na handling in the proximal tubule in humans, this change would imply a fall in FPR/sub Na/, suggesting a much larger shift in tubular Na reabsorption in escape than hitherto suspected. In addition, it would suggest that the inevitable back diffusion of a part of the solute-free water in the distal nephron, and thus overestimation of FPR/sub Na/ by the C/sub H/sub 2/O/ method, increases importantly during escape. Alternately, lithium may not be a good marker of proximal tubular Na handling. For instance, both lithium reabsorption and escape may take place beyond the proximal tubule, or lithium may be excreted in the distal nephron in certain conditions. Present methods do not permit further analysis of these options in the human model.

  11. Textbook Factor Demand Curves.

    ERIC Educational Resources Information Center

    Davis, Joe C.

    1994-01-01

    Maintains that teachers and textbook graphics follow the same basic pattern in illustrating changes in demand curves when product prices increase. Asserts that the use of computer graphics will enable teachers to be more precise in their graphic presentation of price elasticity. (CFR)

  12. Curve Fit Challenge

    ERIC Educational Resources Information Center

    Harper, Suzanne R.; Driskell, Shannon

    2005-01-01

    Graphic tips for using the Geometer's Sketchpad (GSP) are described. The methods to import an image into GSP, define a coordinate system, plot points and curve fit the function using a graphical calculator are demonstrated where the graphic features of GSP allow teachers to expand the use of the technology application beyond the classroom.

  13. Graphing Polar Curves

    ERIC Educational Resources Information Center

    Lawes, Jonathan F.

    2013-01-01

    Graphing polar curves typically involves a combination of three traditional techniques, all of which can be time-consuming and tedious. However, an alternative method--graphing the polar function on a rectangular plane--simplifies graphing, increases student understanding of the polar coordinate system, and reinforces graphing techniques learned…

  14. The Bacterial Growth Curve.

    ERIC Educational Resources Information Center

    Paulton, Richard J. L.

    1991-01-01

    A procedure that allows students to view an entire bacterial growth curve during a two- to three-hour student laboratory period is described. Observations of the lag phase, logarithmic phase, maximum stationary phase, and phase of decline are possible. A nonpathogenic, marine bacterium is used in the investigation. (KR)

  15. Comparing Item Characteristic Curves.

    ERIC Educational Resources Information Center

    Rosenbaum, Paul R.

    1987-01-01

    This paper develops and applies three nonparametric comparisons of the shapes of two item characteristic surfaces: (1) proportional latent odds; (2) uniform relative difficulty; and (3) item sensitivity. A method is presented for comparing the relative shapes of two item characteristic curves in two examinee populations who were administered an…

  16. Straightening Out Learning Curves

    ERIC Educational Resources Information Center

    Corlett, E. N.; Morecombe, V. J.

    1970-01-01

    The basic mathematical theory behind learning curves is explained, together with implications for clerical and industrial training, evaluation of skill development, and prediction of future performance. Brief studies of textile worker and typist training are presented to illustrate such concepts as the reduction fraction (a consistent decrease in…

  17. Amylase creatinine clearance ratio after biliary surgery.

    PubMed

    Donaldson, L A; McIntosh, W; Joffe, S N

    1977-01-01

    The amylase creatinine clearance ratio (ACCR) is considered to be a more sensitive index of acute pancreatitis than the serum amylase level. Serial ACCR estimations were undertaken in 25 patients undergoing an elective cholecystectomy. Using accepted criteria, 28% of these patients developed, in the postoperative period, biochemical evidence of pancreatic gland damage, although the serum amylase level remained normal. This raised ACCR was particularly noted in patients who had undergone an exploration of the common bile duct. The ACCR would appear to be a more sensitive index of pancreatic gland disruption secondary to biliary surgery than the serum amylase level.

  18. Amylase creatinine clearance ratio after biliary surgery.

    PubMed

    Donaldson, L A; McIntosh, W; Joffe, S N

    1977-01-01

    The amylase creatinine clearance ratio (ACCR) is considered to be a more sensitive index of acute pancreatitis than the serum amylase level. Serial ACCR estimations were undertaken in 25 patients undergoing an elective cholecystectomy. Using accepted criteria, 28% of these patients developed, in the postoperative period, biochemical evidence of pancreatic gland damage, although the serum amylase level remained normal. This raised ACCR was particularly noted in patients who had undergone an exploration of the common bile duct. The ACCR would appear to be a more sensitive index of pancreatic gland disruption secondary to biliary surgery than the serum amylase level. PMID:402305

  19. Study of blade clearance effects on centrifugal pumps

    NASA Technical Reports Server (NTRS)

    Hoshide, R. K.; Nielson, C. E.

    1972-01-01

    A program of analysis, design, fabrication, and testing has been conducted to develop and experimentally verify analytical models to predict the effects of impeller blade clearance on centrifugal pumps. The effect of tip clearance on pump efficiency, and the relationship between the head coefficient and torque loss with tip clearance was established. Analysis were performed to determine the cost variation in design, manufacture, and test that would occur between unshrouded and shrouded impellers. An impeller, representative of typical rocket engine impellers, was modified by removing its front shroud to permit variation of its blade clearances. It was tested in water with special instrumentation to provide measurements of blade surface pressures during operation. Pump performance data were obtained from tests at various impeller tip clearances. Blade pressure data were obtained at the nominal tip clearance. Comparisons of predicted and measured data are given.

  20. Mucociliary clearance following segmental tracheal reversal.

    PubMed

    Delaere, P R; Liu, Z; Delanghe, G; Gyselen, K; Jorissen, M; Feenstra, L

    1996-04-01

    Ciliated tracheal epithelium is arranged in a polarized pattern oriented according to the inferior-superior axis of the trachea and is responsible for the transport of mucus toward the larynx. In this study, ciliary beat orientation and the influence of external factors on mucociliary clearance direction were studied in rabbit inverted cervical tracheas. The animals displayed normal respiration postoperatively. After 16 weeks, airway clearance was studied by observation of the movement of silicone particles placed in the inverted segment and in normal parts of the ciliated epithelium. Cilia exhibited unidirectional and coordinated movement within inverted tracheal segments. As shown by the direction of effective flow produced by beating cilia and by scanning electron microscopy, the cilia in the inverted segment beat in the opposite direction from the cilia in the remainder of the trachea. This study demonstrated that ciliary orientation is irreversibly determined, but the reversal of ciliary beating within the cervical trachea had no adverse effects on the survival of the animals.

  1. Deposition and clearance of inhaled particles.

    PubMed Central

    Stuart, B O

    1984-01-01

    Theoretical models of respiratory tract deposition of inhaled particles are compared to experimental studies of deposition patterns in humans and animals, as governed principally by particle size, density, respiratory rate and flow parameters. Various models of inhaled particle deposition make use of approximations of the respiratory tract to predict fractional deposition caused by fundamental physical processes of particle impaction, sedimentation, and diffusion. These models for both total deposition and regional (nasopharyngeal, tracheobronchial, and pulmonary) deposition are compared with early and recent experimental studies. Reasonable correlation has been obtained between theoretical and experimental studies, but the behavior in the respiratory tract of very fine (less than 0.1 micron) particles requires further investigation. Properties of particle shape, charge and hygroscopicity as well as the degree of respiratory tract pathology also influence deposition patterns; definitive experimental work is needed in these areas. The influence upon deposition patterns of dynamic alterations in inspiratory flow profiles caused by a variety of breathing patterns also requires further study, and the use of differing ventilation techniques with selected inhaled particle sizes holds promise in diagnosis of respiratory tract diseases. Mechanisms of conducting airway and alveolar clearance processes involving the pulmonary macrophage, mucociliary clearance, dissolution, transport to systemic circulation, and translocation via regional lymphatic vessels are discussed. PMID:6376108

  2. Surfactant secretion and clearance in the newborn

    SciTech Connect

    Stevens, P.A.; Wright, J.R.; Clements, J.A. )

    1989-10-01

    Pregnant rabbits (30 days) were injected intravenously with (3H)choline 8 h before delivery. The fetuses were delivered, and lung lavage and lamellar body phospholipids (PL) were analyzed. Some newborns also received radioactively labeled surfactant intratracheally on delivery and were permitted to breathe. With time, intratracheal label decreased in lavage and appeared in the lamellar body fraction, and intravenous label accumulated in both pools. Using a tracer analysis for non-steady state, we calculated surfactant secretion and clearance rates for the newborn period. Before birth, both rates rose slightly from 1.8 micrograms PL.g body wt-1.h-1 at 6 h before birth to 7.3 at birth. Immediately after birth, secretion rate rose to 37.7 micrograms PL.g body wt-1.h-1. Between 1.5 and 2 h after birth it fell to a minimum of 1.8 micrograms PL.g body wt-1.h-1 and then rose slowly to 6.0 at 12 h. After birth, clearance rate increased less than secretion rate (maximum 24.7 micrograms PL.g body wt-1.h-1 shortly after birth) then followed the same pattern but did not balance secretion rate in the 1st day.

  3. Renal Clearance of Mineral Metabolism Biomarkers.

    PubMed

    van Ballegooijen, Adriana J; Rhee, Eugene P; Elmariah, Sammy; de Boer, Ian H; Kestenbaum, Bryan

    2016-02-01

    CKD leads to disturbances in multiple interrelated hormones that regulate bone and mineral metabolism. The renal handling of mineral metabolism hormones in humans is incompletely understood. We determined the single-pass renal clearance of parathyroid hormone, fibroblast growth factor 23, vitamin D metabolites, and phosphate from paired blood samples collected from the abdominal aorta and renal vein in 17 participants undergoing simultaneous right and left heart catheterization and estimated associations of eGFR with the renal elimination of metabolites. The mean age ±SD of the study population was 71.4±10.0 years and 11 participants (65%) were male. We found a relatively large mean±SD single-pass renal extraction of parathyroid hormone (44.2%±10.3%) that exceeded the extraction of creatinine (22.1%±7.9%). The proportionate renal extraction of parathyroid hormone correlated with eGFR. The renal extraction of fibroblast growth factor 23 was, on average, lower than that of parathyroid hormone with greater variability across individuals (17.1%±19.5%). There were no differences in the mean concentrations of vitamin D metabolites across the renal vein and artery. In summary, we demonstrate substantial single-pass renal extraction of parathyroid hormone at a rate that exceeds glomerular filtration. Impaired renal clearance of parathyroid hormone may contribute to secondary hyperparathyroidism in CKD.

  4. Factorization with genus 2 curves

    NASA Astrophysics Data System (ADS)

    Cosset, Romain

    2010-04-01

    The elliptic curve method (ECM) is one of the best factorization methods available. It is possible to use hyperelliptic curves instead of elliptic curves but it is in theory slower. We use special hyperelliptic curves and Kummer surfaces to reduce the complexity of the algorithm. Our implementation GMP-HECM is faster than GMP-ECM for factoring large numbers.

  5. Nicotinic acid test in the diagnosis of Gilbert's syndrome: correlation with bilirubin clearance.

    PubMed Central

    Röllinghoff, W; Paumgartner, G; Preisig, R

    1981-01-01

    A provocation test with nicotinic acid (50 mg intravenously) was performed in 13 patients with Gilbert's syndrome and seven healthy volunteers to investigate the diagnostic value of several test parameters and to correlate them with the bilirubin clearance. The maximal increment of unconjugated serum bilirubin, the retention at four hours, and the area under the bilirubin concentration time curve. (AUC) were measured. Significant differences between patients and controls were found with regard to the AUC (7.95 +/- SD, 3.29 mmol/min/l vs. 3.08 +/- 0.57; P less than 0.001), the increment of unconjugated bilirubin (24.1 +/- 7.1 mumol/l vs. 10.2 +/- 3.2; P less than 0.001) and the retention (77.7 +/- 8.9% vs. 45.8 +/- 27.4%; P less than 0.02). Of those, the AUC discriminated best between patients and controls. Five patients with Gilbert's syndrome had normal serum bilirubin concentrations (less than 17.1 mumol/l = 1 mg%) at the time of the study, but abnormal AUC and bilirubin increment. A significant correlation was found between the bilirubin clearance and the retention (r = -0.96; P less than 0.001) as well as the AUC (r = -0.82; P less than 0.05) but not with the bilirubin increment. This simple test may be used to assess the disturbance of bilirubin clearance in Gilbert's syndrome. PMID:7286783

  6. Scintigraphic monitoring of mucociliary tracheo-bronchial clearance of technetium-99m macroaggregated albumin aerosol

    SciTech Connect

    Zwas, S.T.; Katz, I.; Belfer, B.; Baum, G.L.; Aharonson, E.

    1987-02-01

    A simple method for in vivo monitoring mucociliary tracheo-bronchial clearance is described. Eighteen healthy subjects and 13 patients with various chronic lung diseases were studied by this method. The principle of using an aerosol administration system similar to the system used for routine ventilation lung studies is stressed. Proximal large airway deposition of the radioaerosol was obtained by using relatively large particles (average diameter 2 microM) of (99mTc)MAA aerosol. Monitoring was performed by visual inspection of the tracheo-bronchial cinescintigraphic ascendence of the accumulated radioactive boli and by assessing their rate of clearance via automated computer analysis of the time-activity curves, following the movement of each bolus. The normal mean +/- s.d. clearance rate thus obtained was 4.7 +/- 1.3 mm/min. This rate appears to be more precise as compared with the range of results obtained by other radioisotopic methods. Significantly faster rates, mean 8.2 +/- 1.4 mm/min (p less than 0.001) were obtained in bronchiectatic patients while slower rates (2.8 mm/min) were seen in a patient with ciliary dyskinesia.

  7. Fuel conservation through active control of rotor clearances

    NASA Technical Reports Server (NTRS)

    Beitler, R. S.; Saunders, A. A.; Wanger, R. P.

    1980-01-01

    Under the NASA-sponsored Energy Efficient Engine (EEE) Project, technology is being developed which will significantly reduce the fuel consumption of turbofan engines for subsonic transport aircraft. One technology concept being pursued is active control of rotor tip clearances. Attention is given to rotor tip clearance considerations and an overview of preliminary study results as well as the General Electric EEE clearance control approach is presented. Finally, potential fuel savings with active control of rotor clearances for a typical EEE mission are predicted.

  8. ESR measurement of radical clearance in lung of whole mouse

    SciTech Connect

    Takeshita, K.; Utsumi, H.; Hamada, A. )

    1991-06-14

    Clearance of the nitroxide radicals, hydroxy-TEMPO and carboxy-PROxYL, in whole-mouse lung was directly measured by in vivo ESR. After injecting a nitroxide radical, distribution of the nitroxide radical all over the lung was confirmed by ESR imaging. The ESR signal of hydroxy-TEMPO was reduced in the lung and the clearance obeyed first-order kinetics, whereas the signal of carboxy-PROxYL remained constant. Comparison of the clearance rates of live and dead mice indicated the presence of 2 different clearance systems in the lung: loss of its paramagnetism in the lung, and transfer from alveolar to the blood circulation system.

  9. Trishear for curved faults

    NASA Astrophysics Data System (ADS)

    Brandenburg, J. P.

    2013-08-01

    Fault-propagation folds form an important trapping element in both onshore and offshore fold-thrust belts, and as such benefit from reliable interpretation. Building an accurate geologic interpretation of such structures requires palinspastic restorations, which are made more challenging by the interplay between folding and faulting. Trishear (Erslev, 1991; Allmendinger, 1998) is a useful tool to unravel this relationship kinematically, but is limited by a restriction to planar fault geometries, or at least planar fault segments. Here, new methods are presented for trishear along continuously curved reverse faults defining a flat-ramp transition. In these methods, rotation of the hanging wall above a curved fault is coupled to translation along a horizontal detachment. Including hanging wall rotation allows for investigation of structures with progressive backlimb rotation. Application of the new algorithms are shown for two fault-propagation fold structures: the Turner Valley Anticline in Southwestern Alberta, and the Alpha Structure in the Niger Delta.

  10. Mouse Curve Biometrics

    SciTech Connect

    Schulz, Douglas A.

    2007-10-08

    A biometric system suitable for validating user identity using only mouse movements and no specialized equipment is presented. Mouse curves (mouse movements with little or no pause between them) are individually classied and used to develop classication histograms, which are representative of an individual's typical mouse use. These classication histograms can then be compared to validate identity. This classication approach is suitable for providing continuous identity validation during an entire user session.

  11. Anatomical curve identification

    PubMed Central

    Bowman, Adrian W.; Katina, Stanislav; Smith, Joanna; Brown, Denise

    2015-01-01

    Methods for capturing images in three dimensions are now widely available, with stereo-photogrammetry and laser scanning being two common approaches. In anatomical studies, a number of landmarks are usually identified manually from each of these images and these form the basis of subsequent statistical analysis. However, landmarks express only a very small proportion of the information available from the images. Anatomically defined curves have the advantage of providing a much richer expression of shape. This is explored in the context of identifying the boundary of breasts from an image of the female torso and the boundary of the lips from a facial image. The curves of interest are characterised by ridges or valleys. Key issues in estimation are the ability to navigate across the anatomical surface in three-dimensions, the ability to recognise the relevant boundary and the need to assess the evidence for the presence of the surface feature of interest. The first issue is addressed by the use of principal curves, as an extension of principal components, the second by suitable assessment of curvature and the third by change-point detection. P-spline smoothing is used as an integral part of the methods but adaptations are made to the specific anatomical features of interest. After estimation of the boundary curves, the intermediate surfaces of the anatomical feature of interest can be characterised by surface interpolation. This allows shape variation to be explored using standard methods such as principal components. These tools are applied to a collection of images of women where one breast has been reconstructed after mastectomy and where interest lies in shape differences between the reconstructed and unreconstructed breasts. They are also applied to a collection of lip images where possible differences in shape between males and females are of interest. PMID:26041943

  12. A Novel Technique of Contrast-Enhanced Optical Coherence Tomography Imaging in Evaluation of Clearance of Lipids in Human Tears

    PubMed Central

    Napoli, Pietro Emanuele; Coronella, Franco; Satta, Giovanni Maria; Fossarello, Maurizio

    2014-01-01

    Purpose The aim of this work was to gather preliminary data in different conditions of healthy eyes, aqueous tear deficient dry eyes, obstructive meibomian gland disease (MGD) and non-obvious obstructive MGD (NOMGD) individuals, using a new, contrast-enhanced optical coherence tomography (OCT) imaging method to evaluate the clearance of lipids in human tears. Methods Eighty-two adult patients presenting with complaints of ocular irritation were studied for abnormalities of the ocular surface and classified as healthy (n = 21), aqueous tear deficient dry eyes (n = 20), obstructive MGD (n = 15) and NOMGD (n = 26) individuals. A lipid-based tracer, containing an oil-in-water emulsion, was used to obtain an enhanced OCT imaging of the lower tear meniscus. After instillation, a dramatic initial increase of reflectivity of the lower tear meniscus was detected by OCT, followed by a decay back to baseline values over time. Based on this finding, the clearance of lipids was measured in real-time by Fourier-domain anterior segment OCT. Results The differences in the clearance of lipids among the four groups as well as the correlations between symptom questionnaire score, standardized visual scale test, fluorescein break-up time, ocular surface fluorescein staining score, Schirmer I test scores were found to be statistically significant. The individual areas under the curve of the clearance of lipids calculated by the receiver operating characteristic curve technique ranged from 0.66 to 0.98, suggesting reliable sensitivity and specificity of lipid-enhanced OCT imaging. Conclusions This new technique of contrast-enhanced OCT imaging of the tear film following lipid-based tracer instillation provides a measure of the clearance of lipids. The quantitative values found are in agreement with other methods of evaluation of the lacrimal system. An improvement of the clinician's ability in the diagnosis and understanding of abnormalities of the ocular surface may be

  13. Smarandache curves according to Sabban frame of fixed pole curve belonging to the Bertrand curves pair

    NASA Astrophysics Data System (ADS)

    Şenyurt, Süleyman; Altun, Yasin; Cevahir, Ceyda

    2016-04-01

    In this paper, we investigate the Smarandache curves according to Sabban frame of fixed pole curve which drawn by the unit Darboux vector of the Bertrand partner curve. Some results have been obtained. These results were expressed as the depends Bertrand curve.

  14. Ext1 heterozygosity causes a modest effect on postprandial lipid clearance in humans.

    PubMed

    Mooij, Hans L; Bernelot Moens, Sophie J; Gordts, Philip L S M; Stanford, Kristin I; Foley, Erin M; van den Boogert, Marjolein A W; Witjes, Julia J; Hassing, H Carlijne; Tanck, Michael W; van de Sande, Michiel A J; Levels, J Han; Kastelein, John J P; Stroes, Erik S G; Dallinga-Thie, Geesje M; Esko, Jeff D; Nieuwdorp, Max

    2015-03-01

    Elevated nonfasting TG-rich lipoprotein levels are a risk factor for CVD. To further evaluate the relevance of LDL-receptor (LDLr) pathway and heparan sulfate proteoglycans (HSPGs) in TG homeostasis, we analyzed fasting and postprandial TG levels in mice bearing combined heterozygous mutations in both Exostosin (Ext) 1 and Ldlr, in subjects with hereditary multiple exostosis (HME) due to a heterozygous loss-of-function mutation in EXT1 or EXT2 (N = 13), and in patients with heterozygous mutations in LDLR [familial hypercholesterolemia (FH)] and SNPs in major HSPG-related genes (n = 22). Mice bearing a homozygous mutation in hepatic Ext1 exhibited elevated plasma TGs similar to mice lacking other key enzymes involved in HSPG assembly. Compound heterozygous mice lacking Ldlr and Ext1 showed synergy on plasma TG accumulation and postprandial clearance. In human subjects, a trend was observed in HME patients toward reduced postprandial TG clearance with a concomitant reduction in chylomicron clearance [area under the curve (AUC)-retinyl ester (RE) HME, 844 ± 127 vs. controls, 646 ± 119 nM/h, P = 0.09]. Moreover, in FH subjects with a high HSPG gene score, retinyl palmitate excursions were higher (AUC-RE, 2,377 ± 293 vs. 1,565 ± 181 nM/h, P < 0.05). Incremental AUC-apoB48 was similar between the groups. In conclusion, the data are supportive for a minor yet additive role of HSPG in human postprandial TG clearance, and further studies are warranted. PMID:25568062

  15. Magnetism in curved geometries

    NASA Astrophysics Data System (ADS)

    Streubel, Robert; Fischer, Peter; Kronast, Florian; Kravchuk, Volodymyr P.; Sheka, Denis D.; Gaididei, Yuri; Schmidt, Oliver G.; Makarov, Denys

    2016-09-01

    Extending planar two-dimensional structures into the three-dimensional space has become a general trend in multiple disciplines, including electronics, photonics, plasmonics and magnetics. This approach provides means to modify conventional or to launch novel functionalities by tailoring the geometry of an object, e.g. its local curvature. In a generic electronic system, curvature results in the appearance of scalar and vector geometric potentials inducing anisotropic and chiral effects. In the specific case of magnetism, even in the simplest case of a curved anisotropic Heisenberg magnet, the curvilinear geometry manifests two exchange-driven interactions, namely effective anisotropy and antisymmetric exchange, i.e. Dzyaloshinskii–Moriya-like interaction. As a consequence, a family of novel curvature-driven effects emerges, which includes magnetochiral effects and topologically induced magnetization patterning, resulting in theoretically predicted unlimited domain wall velocities, chirality symmetry breaking and Cherenkov-like effects for magnons. The broad range of altered physical properties makes these curved architectures appealing in view of fundamental research on e.g. skyrmionic systems, magnonic crystals or exotic spin configurations. In addition to these rich physics, the application potential of three-dimensionally shaped objects is currently being explored as magnetic field sensorics for magnetofluidic applications, spin-wave filters, advanced magneto-encephalography devices for diagnosis of epilepsy or for energy-efficient racetrack memory devices. These recent developments ranging from theoretical predictions over fabrication of three-dimensionally curved magnetic thin films, hollow cylinders or wires, to their characterization using integral means as well as the development of advanced tomography approaches are in the focus of this review.

  16. Magnetism in curved geometries

    NASA Astrophysics Data System (ADS)

    Streubel, Robert; Fischer, Peter; Kronast, Florian; Kravchuk, Volodymyr P.; Sheka, Denis D.; Gaididei, Yuri; Schmidt, Oliver G.; Makarov, Denys

    2016-09-01

    Extending planar two-dimensional structures into the three-dimensional space has become a general trend in multiple disciplines, including electronics, photonics, plasmonics and magnetics. This approach provides means to modify conventional or to launch novel functionalities by tailoring the geometry of an object, e.g. its local curvature. In a generic electronic system, curvature results in the appearance of scalar and vector geometric potentials inducing anisotropic and chiral effects. In the specific case of magnetism, even in the simplest case of a curved anisotropic Heisenberg magnet, the curvilinear geometry manifests two exchange-driven interactions, namely effective anisotropy and antisymmetric exchange, i.e. Dzyaloshinskii-Moriya-like interaction. As a consequence, a family of novel curvature-driven effects emerges, which includes magnetochiral effects and topologically induced magnetization patterning, resulting in theoretically predicted unlimited domain wall velocities, chirality symmetry breaking and Cherenkov-like effects for magnons. The broad range of altered physical properties makes these curved architectures appealing in view of fundamental research on e.g. skyrmionic systems, magnonic crystals or exotic spin configurations. In addition to these rich physics, the application potential of three-dimensionally shaped objects is currently being explored as magnetic field sensorics for magnetofluidic applications, spin-wave filters, advanced magneto-encephalography devices for diagnosis of epilepsy or for energy-efficient racetrack memory devices. These recent developments ranging from theoretical predictions over fabrication of three-dimensionally curved magnetic thin films, hollow cylinders or wires, to their characterization using integral means as well as the development of advanced tomography approaches are in the focus of this review.

  17. Spontaneous Clearance of Hepatitis C Virus during Pregnancy

    PubMed Central

    Clohessy, Penelope; Polis, Suzanne; Post, Jeffrey

    2013-01-01

    Spontaneous clearance of hepatitis C virus (HCV) is expected to be unlikely in pregnancy due to the relative immunosuppression and increase in viraemia that occurs. We report the first case of spontaneous clearance of hepatitis C virus (HCV) occurring in pregnancy. PMID:27757149

  18. 10 CFR 706.13 - Clearance of counsel.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 10 Energy 4 2010-01-01 2010-01-01 false Clearance of counsel. 706.13 Section 706.13 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Security Policies and Procedures in National Labor Relations Board Proceedings § 706.13 Clearance of counsel. It...

  19. 10 CFR 706.13 - Clearance of counsel.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Clearance of counsel. 706.13 Section 706.13 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Security Policies and Procedures in National Labor Relations Board Proceedings § 706.13 Clearance of counsel. It...

  20. 10 CFR 706.31 - Clearance of conciliators and arbitrators.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 10 Energy 4 2011-01-01 2011-01-01 false Clearance of conciliators and arbitrators. 706.31 Section 706.31 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Contract Negotiation and Administration § 706.31 Clearance of conciliators and...

  1. 10 CFR 706.13 - Clearance of counsel.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Clearance of counsel. 706.13 Section 706.13 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Security Policies and Procedures in National Labor Relations Board Proceedings § 706.13 Clearance of counsel. It...

  2. 10 CFR 706.31 - Clearance of conciliators and arbitrators.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Clearance of conciliators and arbitrators. 706.31 Section 706.31 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Contract Negotiation and Administration § 706.31 Clearance of conciliators and...

  3. 10 CFR 706.13 - Clearance of counsel.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 10 Energy 4 2014-01-01 2014-01-01 false Clearance of counsel. 706.13 Section 706.13 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Security Policies and Procedures in National Labor Relations Board Proceedings § 706.13 Clearance of counsel. It...

  4. 10 CFR 706.31 - Clearance of conciliators and arbitrators.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Clearance of conciliators and arbitrators. 706.31 Section 706.31 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Contract Negotiation and Administration § 706.31 Clearance of conciliators and...

  5. 10 CFR 706.31 - Clearance of conciliators and arbitrators.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 10 Energy 4 2012-01-01 2012-01-01 false Clearance of conciliators and arbitrators. 706.31 Section 706.31 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Contract Negotiation and Administration § 706.31 Clearance of conciliators and...

  6. 10 CFR 706.13 - Clearance of counsel.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 10 Energy 4 2013-01-01 2013-01-01 false Clearance of counsel. 706.13 Section 706.13 Energy DEPARTMENT OF ENERGY SECURITY POLICIES AND PRACTICES RELATING TO LABOR-MANAGEMENT RELATIONS Security Policies and Procedures in National Labor Relations Board Proceedings § 706.13 Clearance of counsel. It...

  7. Land clearance in the irish neolithic: new evidence and interpretation.

    PubMed

    Pilcher, J R; Smith, A G; Pearson, G W; Crowder, A

    1971-05-01

    Time scales are derived, from radiocarbon dating of pollen diagrams, for Neolithic land clearance at three Irish sites. Three stages are distinguished beginning in the 4th millennium B.C.: stage A, clearance and farming (possibly arable), 100 to 400 years; stage B, farming (possibly pastoral), 150 to 200 years; and stage C, forest regeneration, 50 to 100 years.

  8. Study of global operational needs for mine clearance equipment

    NASA Astrophysics Data System (ADS)

    Blagden, Paddy M.

    2003-09-01

    The Geneva International Centre for Humanitarian Demining studied the needs of landmine clearance groups for equipment to carry out specific functions of mine clearance. This was done on a global level, and useful results were obtained, which will provide the basis for further analysis.

  9. 33 CFR 118.160 - Vertical clearance gauges.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 33 Navigation and Navigable Waters 1 2011-07-01 2011-07-01 false Vertical clearance gauges. 118.160 Section 118.160 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY BRIDGES BRIDGE LIGHTING AND OTHER SIGNALS § 118.160 Vertical clearance gauges. (a) When necessary...

  10. 32 CFR 644.521 - Limitations on clearance cost.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Limitations on clearance cost. 644.521 Section 644.521 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from...

  11. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking...

  12. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 1 2010-10-01 2010-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance...

  13. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 5 2010-10-01 2010-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to...

  14. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 1 2013-10-01 2013-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance...

  15. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to...

  16. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to...

  17. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to...

  18. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking...

  19. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 1 2012-10-01 2012-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance...

  20. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 48 Federal Acquisition Regulations System 5 2012-10-01 2012-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking...

  1. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 1 2014-10-01 2014-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance...

  2. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 48 Federal Acquisition Regulations System 5 2013-10-01 2013-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking...

  3. 76 FR 17615 - Highway-Rail Grade Crossing; Safe Clearance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-30

    ... Crossing; Safe Clearance Notice of Proposed Rulemaking, which was published on January 28, 2011 (76 FR 5120... Parts 177 and 392 RIN 2137-AE69 & 2126-AB04 Highway-Rail Grade Crossing; Safe Clearance AGENCY: Pipeline... that PHMSA and FMCSA extend the comment period for the Highway-Rail Grade Crossing; Safe...

  4. 48 CFR 945.670-1 - Plant clearance function.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Plant clearance function. 945.670-1 Section 945.670-1 Federal Acquisition Regulations System DEPARTMENT OF ENERGY CONTRACT MANAGEMENT GOVERNMENT PROPERTY Reporting, Reutilization, and Disposal 945.670-1 Plant clearance function....

  5. 48 CFR 32.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 1 2011-10-01 2011-10-01 false Contract finance office clearance. 32.502-2 Section 32.502-2 Federal Acquisition Regulations System FEDERAL ACQUISITION REGULATION... finance office clearance. The contracting officer shall obtain the approval of the contract finance...

  6. 48 CFR 1432.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Contract finance office clearance. 1432.502-2 Section 1432.502-2 Federal Acquisition Regulations System DEPARTMENT OF THE INTERIOR... finance office clearance. The CO shall obtain approval of the bureau finance office prior to...

  7. 48 CFR 832.502-2 - Contract finance office clearance.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Contract finance office clearance. 832.502-2 Section 832.502-2 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS... finance office clearance. Contracting officers must obtain approval from the DSPE before taking...

  8. 32 CFR 644.522 - Clearance of military scrap.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... destruction, by using command, of all military scrap and scrap metal from lands suitable for cultivation...

  9. 32 CFR 644.522 - Clearance of military scrap.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... destruction, by using command, of all military scrap and scrap metal from lands suitable for cultivation...

  10. 32 CFR 644.522 - Clearance of military scrap.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... destruction, by using command, of all military scrap and scrap metal from lands suitable for cultivation...

  11. 32 CFR 644.516 - Clearance of Air Force lands.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 32 National Defense 4 2011-07-01 2011-07-01 false Clearance of Air Force lands. 644.516 Section... Excess Land and Improvements § 644.516 Clearance of Air Force lands. The Chief of Engineers has no responsibility for inspecting or clearing excess Air Force land of explosives or chemical/biological...

  12. 32 CFR 644.521 - Limitations on clearance cost.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Limitations on clearance cost. 644.521 Section 644.521 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from...

  13. 32 CFR 644.527 - Recording Statements of Clearance.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Recording Statements of Clearance. 644.527 Section 644.527 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from...

  14. 24 CFR 3285.305 - Clearance under homes.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 24 Housing and Urban Development 5 2014-04-01 2014-04-01 false Clearance under homes. 3285.305 Section 3285.305 Housing and Urban Development Regulations Relating to Housing and Urban Development... URBAN DEVELOPMENT MODEL MANUFACTURED HOME INSTALLATION STANDARDS Foundations § 3285.305 Clearance...

  15. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 20 Employees' Benefits 3 2011-04-01 2011-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated...

  16. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 20 Employees' Benefits 3 2014-04-01 2014-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated...

  17. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 20 Employees' Benefits 3 2012-04-01 2012-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated...

  18. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 20 Employees' Benefits 3 2010-04-01 2010-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated...

  19. 20 CFR 655.150 - Interstate clearance of job order.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 20 Employees' Benefits 3 2013-04-01 2013-04-01 false Interstate clearance of job order. 655.150... job order. (a) SWA posts in interstate clearance system. The SWA must promptly place the job order in... transmit a copy of its active job order to all States listed in the job order as anticipated...

  20. 14 CFR 93.311 - Minimum terrain clearance.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 14 Aeronautics and Space 2 2010-01-01 2010-01-01 false Minimum terrain clearance. 93.311 Section... of Grand Canyon National Park, AZ § 93.311 Minimum terrain clearance. Except in an emergency, when... a purpose listed in § 93.309(c), no person may operate an aircraft within 500 feet of any terrain...

  1. 14 CFR 93.311 - Minimum terrain clearance.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 14 Aeronautics and Space 2 2014-01-01 2014-01-01 false Minimum terrain clearance. 93.311 Section... of Grand Canyon National Park, AZ § 93.311 Minimum terrain clearance. Except in an emergency, when... a purpose listed in § 93.309(c), no person may operate an aircraft within 500 feet of any terrain...

  2. 14 CFR 93.311 - Minimum terrain clearance.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 14 Aeronautics and Space 2 2011-01-01 2011-01-01 false Minimum terrain clearance. 93.311 Section... of Grand Canyon National Park, AZ § 93.311 Minimum terrain clearance. Except in an emergency, when... a purpose listed in § 93.309(c), no person may operate an aircraft within 500 feet of any terrain...

  3. 14 CFR 93.311 - Minimum terrain clearance.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 14 Aeronautics and Space 2 2012-01-01 2012-01-01 false Minimum terrain clearance. 93.311 Section... of Grand Canyon National Park, AZ § 93.311 Minimum terrain clearance. Except in an emergency, when... a purpose listed in § 93.309(c), no person may operate an aircraft within 500 feet of any terrain...

  4. 14 CFR 93.311 - Minimum terrain clearance.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 14 Aeronautics and Space 2 2013-01-01 2013-01-01 false Minimum terrain clearance. 93.311 Section... of Grand Canyon National Park, AZ § 93.311 Minimum terrain clearance. Except in an emergency, when... a purpose listed in § 93.309(c), no person may operate an aircraft within 500 feet of any terrain...

  5. 49 CFR 229.71 - Clearance above top of rail.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 49 Transportation 4 2012-10-01 2012-10-01 false Clearance above top of rail. 229.71 Section 229.71....71 Clearance above top of rail. No part or appliance of a locomotive except the wheels, flexible nonmetallic sand pipe extension tips, and trip cock arms may be less than 21/2 inches above the top of rail....

  6. 49 CFR 229.71 - Clearance above top of rail.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 4 2014-10-01 2014-10-01 false Clearance above top of rail. 229.71 Section 229.71....71 Clearance above top of rail. No part or appliance of a locomotive except the wheels, flexible nonmetallic sand pipe extension tips, and trip cock arms may be less than 21/2 inches above the top of rail....

  7. 49 CFR 229.71 - Clearance above top of rail.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 4 2013-10-01 2013-10-01 false Clearance above top of rail. 229.71 Section 229.71....71 Clearance above top of rail. No part or appliance of a locomotive except the wheels, flexible nonmetallic sand pipe extension tips, and trip cock arms may be less than 21/2 inches above the top of rail....

  8. 49 CFR 229.71 - Clearance above top of rail.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 4 2011-10-01 2011-10-01 false Clearance above top of rail. 229.71 Section 229.71....71 Clearance above top of rail. No part or appliance of a locomotive except the wheels, flexible nonmetallic sand pipe extension tips, and trip cock arms may be less than 21/2 inches above the top of rail....

  9. 32 CFR 644.516 - Clearance of Air Force lands.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Clearance of Air Force lands. 644.516 Section 644... Excess Land and Improvements § 644.516 Clearance of Air Force lands. The Chief of Engineers has no responsibility for inspecting or clearing excess Air Force land of explosives or chemical/biological...

  10. 32 CFR 644.516 - Clearance of Air Force lands.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Clearance of Air Force lands. 644.516 Section 644... Excess Land and Improvements § 644.516 Clearance of Air Force lands. The Chief of Engineers has no responsibility for inspecting or clearing excess Air Force land of explosives or chemical/biological...

  11. 32 CFR 644.516 - Clearance of Air Force lands.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Clearance of Air Force lands. 644.516 Section... Excess Land and Improvements § 644.516 Clearance of Air Force lands. The Chief of Engineers has no responsibility for inspecting or clearing excess Air Force land of explosives or chemical/biological...

  12. 32 CFR 644.522 - Clearance of military scrap.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Clearance of military scrap. 644.522 Section 644... Excess Land and Improvements § 644.522 Clearance of military scrap. Military scrap can contain or be... determining whether scrap metal will be removed should be the safety of persons coming on the land in...

  13. Do dialysate conductivity measurements provide conductivity clearance or ionic dialysance?

    PubMed

    Petitclerc, T

    2006-11-01

    Dialysate conductivity measurements allow on-line estimation of urea clearance during hemodialysis session. Conductivity measurements provide a value of 'conductivity clearance' for some authors, but a value of 'ionic dialysance' for others. This paper aims at explaining which term should be the more appropriate. Clearance is a parameter defined for measuring the power of a mechanism, which aims at 'clearing' a solution by depurating some solutes. In hemodialysis, clearance measures the efficacy of patient's depuration. In contrast, dialysance measures the capability of transferring solutes between blood and dialysate. The conventional definition of dialysance, requiring the absence of convective transfer, should be generalized to the case of the usual presence of ultrafiltration during the hemodialysis session. For a solute (as urea) absent from the dialysate delivered to the dialyzer inlet, the clearance is equal to its dialysance. In order to avoid a dramatic fall in ionic concentrations during hemodialysis treatment, the clearance of ions is reduced by adding these ions in the dialysate and becomes lower than their dialysance. Conductivity measurements provide a value of electrolytes dialysance. Thus the term of 'ionic dialysance' is more appropriate than the term of 'conductivity clearance'. Nevertheless ionic dialysance represents a good estimation of urea clearance.

  14. Allometric scaling for predicting human clearance of bisphenol A

    SciTech Connect

    Collet, Séverine H. Picard-Hagen, Nicole Lacroix, Marlène Z. Puel, Sylvie Viguié, Catherine Bousquet-Melou, Alain Toutain, Pierre-Louis Gayrard, Véronique

    2015-05-01

    The investigation of interspecies differences in bisphenol A (BPA) pharmacokinetics (PK) may be useful for translating findings from animal studies to humans, identifying major processes involved in BPA clearance mechanisms, and predicting BPA PK parameters in man. For the first time, a large range of species in terms of body weight, from 0.02 kg (mice) to 495 kg (horses) was used to predict BPA clearance in man by an allometric approach. BPA PK was evaluated after intravenous administration of BPA in horses, sheep, pigs, dogs, rats and mice. A non-compartmental analysis was used to estimate plasma clearance and steady state volume of distribution and predict BPA PK parameters in humans from allometric scaling. In all the species investigated, BPA plasma clearance was high and of the same order of magnitude as their respective hepatic blood flow. By an allometric scaling, the human clearance was estimated to be 1.79 L/min (equivalent to 25.6 mL/kg.min) with a 95% prediction interval of 0.36 to 8.83 L/min. Our results support the hypothesis that there are highly efficient and hepatic mechanisms of BPA clearance in man. - Highlights: • Allometric scaling was used to predict BPA pharmacokinetic parameters in humans. • In all species, BPA plasma clearance approached hepatic blood flow. • Human BPA clearance was estimated to be 1.79 L/min.

  15. Clearance systems in the brain—implications for Alzheimer disease

    PubMed Central

    Tarasoff-Conway, Jenna M.; Carare, Roxana O.; Osorio, Ricardo S.; Glodzik, Lidia; Butler, Tracy; Fieremans, Els; Axel, Leon; Rusinek, Henry; Nicholson, Charles; Zlokovic, Berislav V.; Frangione, Blas; Blennow, Kaj; Ménard, Joël; Zetterberg, Henrik; Wisniewski, Thomas; de Leon, Mony J.

    2015-01-01

    Accumulation of toxic protein aggregates—amyloid-β (Aβ) plaques and hyperphosphorylated tau tangles—is the pathological hallmark of Alzheimer disease (AD). Aβ accumulation has been hypothesized to result from an imbalance between Aβ production and clearance; indeed, Aβ clearance seems to be impaired in both early and late forms of AD. To develop efficient strategies to slow down or halt AD, it is critical to understand how Aβ is cleared from the brain. Extracellular Aβ deposits can be removed from the brain by various clearance systems, most importantly, transport across the blood–brain barrier. Findings from the past few years suggest that astroglial-mediated interstitial fluid (ISF) bulk flow, known as the glymphatic system, might contribute to a larger portion of extracellular Aβ (eAβ) clearance than previously thought. The meningeal lymphatic vessels, discovered in 2015, might provide another clearance route. Because these clearance systems act together to drive eAβ from the brain, any alteration to their function could contribute to AD. An understanding of Aβ clearance might provide strategies to reduce excess Aβ deposits and delay, or even prevent, disease onset. In this Review, we describe the clearance systems of the brain as they relate to proteins implicated in AD pathology, with the main focus on Aβ. PMID:26195256

  16. 32 CFR 644.521 - Limitations on clearance cost.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 32 National Defense 4 2014-07-01 2013-07-01 true Limitations on clearance cost. 644.521 Section 644.521 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from...

  17. 32 CFR 644.521 - Limitations on clearance cost.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 32 National Defense 4 2013-07-01 2013-07-01 false Limitations on clearance cost. 644.521 Section 644.521 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from...

  18. 32 CFR 644.521 - Limitations on clearance cost.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 32 National Defense 4 2012-07-01 2011-07-01 true Limitations on clearance cost. 644.521 Section 644.521 National Defense Department of Defense (Continued) DEPARTMENT OF THE ARMY (CONTINUED) REAL PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from...

  19. Curved shock theory

    NASA Astrophysics Data System (ADS)

    Mölder, S.

    2016-07-01

    Curved shock theory (CST) is introduced, developed and applied to relate pressure gradients, streamline curvatures, vorticity and shock curvatures in flows with planar or axial symmetry. Explicit expressions are given, in an influence coefficient format, that relate post-shock pressure gradient, streamline curvature and vorticity to pre-shock gradients and shock curvature in steady flow. The effect of pre-shock flow divergence/convergence, on vorticity generation, is related to the transverse shock curvature. A novel derivation for the post-shock vorticity is presented that includes the effects of pre-shock flow non-uniformities. CST applicability to unsteady flows is discussed.

  20. Predicting clearance in humans from in vitro data.

    PubMed

    Obach, R Scott

    2011-01-01

    The use of in vitro metabolism in scaling to predict human clearance of new chemical entities has become a commonplace activity in the research and development of new drugs. The measurement of in vitro lability in human liver microsomes, a rich source of drug metabolizing cytochrome P450 enzymes, has become a high throughput screen in many research organizations which is a testament to its usefulness in drug design. In this chapter, the methods used to scale in vitro clearance data to predict in vivo clearance are described. Importantly, the numerous assumptions that are required in order to use in vitro data in this manner are laid out. These include assumptions regarding the scaling process as well as technical aspects of the generation of the in vitro data. Finally, some other drug clearance processes that have been emerging as important are described with regard to ongoing research efforts to develop clearance prediction methods.

  1. A model of clearance rate regulation in mussels

    NASA Astrophysics Data System (ADS)

    Fréchette, Marcel

    2012-10-01

    Clearance rate regulation has been modelled as an instantaneous response to food availability, independent of the internal state of the animals. This view is incompatible with latent effects during ontogeny and phenotypic flexibility in clearance rate. Internal-state regulation of clearance rate is required to account for these patterns. Here I develop a model of internal-state based regulation of clearance rate. External factors such as suspended sediments are included in the model. To assess the relative merits of instantaneous regulation and internal-state regulation, I modelled blue mussel clearance rate and growth using a DEB model. In the usual standard feeding module, feeding is governed by a Holling's Type II response to food concentration. In the internal-state feeding module, gill ciliary activity and thus clearance rate are driven by internal reserve level. Factors such as suspended sediments were not included in the simulations. The two feeding modules were compared on the basis of their ability to capture the impact of latent effects, of environmental heterogeneity in food abundance and of physiological flexibility on clearance rate and individual growth. The Holling feeding module was unable to capture the effect of any of these sources of variability. In contrast, the internal-state feeding module did so without any modification or ad hoc calibration. Latent effects, however, appeared transient. With simple annual variability in temperature and food concentration, the relationship between clearance rate and food availability predicted by the internal-state feeding module was quite similar to that observed in Norwegian fjords. I conclude that in contrast with the usual Holling feeding module, internal-state regulation of clearance rate is consistent with well-documented growth and clearance rate patterns.

  2. The Characteristic Curves of Water

    NASA Astrophysics Data System (ADS)

    Neumaier, Arnold; Deiters, Ulrich K.

    2016-09-01

    In 1960, E. H. Brown defined a set of characteristic curves (also known as ideal curves) of pure fluids, along which some thermodynamic properties match those of an ideal gas. These curves are used for testing the extrapolation behaviour of equations of state. This work is revisited, and an elegant representation of the first-order characteristic curves as level curves of a master function is proposed. It is shown that Brown's postulate—that these curves are unique and dome-shaped in a double-logarithmic p, T representation—may fail for fluids exhibiting a density anomaly. A careful study of the Amagat curve (Joule inversion curve) generated from the IAPWS-95 reference equation of state for water reveals the existence of an additional branch.

  3. Lactate clearance is associated with mortality in septic patients with acute kidney injury requiring continuous renal replacement therapy

    PubMed Central

    Passos, Rogério da Hora; Ramos, Joao Gabriel Rosa; Gobatto, André; Mendonça, Evandro José Bulhões; Miranda, Eva Alves; Dutra, Fábio Ricardo Dantas; Coelho, Maria Fernanda R; Pedroza, Andrea C; Batista, Paulo Benigno Pena; Dutra, Margarida Maria Dantas

    2016-01-01

    Abstract The aim of the study was to assess the clinical utility of lactate measured at different time points to predict mortality at 48 hours and 28 days in septic patients with acute kidney injury (AKI) requiring continuous renal replacement therapy (CRRT). Consecutive critically ill patients with septic AKI requiring CRRT were prospectively studied. Variables were collected at initiation of CRRT and 24 hours later. In total, 186 patients were analyzed. Overall mortality at 48 hours was 28% and at 28 days was 69%. Initial lactate, lactate at 24 hours and the proportion of patients with a lactate clearance superior to 10% were different between survivors at 28 days [2.0 mmol/L, 1.95 mmol/L and 18/45 (40%)] and nonsurvivors [3.46 mmol, 4.66 mmol, and 18/94 (19%)]. Multivariate analysis demonstrated that lactate at 24 hours and lactate clearance, but not initial lactate, were independently associated to mortality. Area under the ROC curves for 28-day mortality was 0.635 for initial lactate; 0.828 for lactate at 24 hours and 0.701 for lactate clearance. Lactate clearance and lactate after 24 hours of CRRT, but not initial lactate, were independently associated with mortality in septic AKI patients undergoing CRRT. Serial lactate measurements may be useful prognostic markers than initial lactate in these patients. PMID:27749594

  4. 78 FR 40729 - Agency Information Collection Activities; Proposed Collection; Comment Request: Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-07-08

    ...: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Washington... Information Collection Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery Abstract: The...

  5. Titration Curves: Fact and Fiction.

    ERIC Educational Resources Information Center

    Chamberlain, John

    1997-01-01

    Discusses ways in which datalogging equipment can enable titration curves to be measured accurately and how computing power can be used to predict the shape of curves. Highlights include sources of error, use of spreadsheets to generate titration curves, titration of a weak acid with a strong alkali, dibasic acids, weak acid and weak base, and…

  6. Generating Resources Supply Curves.

    SciTech Connect

    United States. Bonneville Power Administration. Division of Power Resources Planning.

    1985-07-01

    This report documents Pacific Northwest supply curve information for both renewable and other generating resources. Resources are characterized as ''Renewable'' and ''Other'' as defined in section 3 or the Pacific Northwest Electric Power Planning and Conservation Act. The following resources are described: renewable: (cogeneration; geothermal; hydroelectric (new); hydroelectric (efficiency improvement); solar; and wind); other (nonrenewable generation resources: coal; combustion turbines; and nuclear. Each resource has the following information documented in tabular format: (1) Technical Characteristics; (2) Costs (capital and O and M); (3) Energy Distribution by Month; and (4) Supply Forecast (energy). Combustion turbine (CT) energy supply is not forecasted because of CT's typical peaking application. Their supply is therefore unconstrained in order to facilitate analysis of their operation in the regional electrical supply system. The generic nuclear resource is considered unavailable to the region over the planning horizon.

  7. Effects of drugs on mucus clearance.

    PubMed

    Houtmeyers, E; Gosselink, R; Gayan-Ramirez, G; Decramer, M

    1999-08-01

    Mucociliary clearance (MCC), the process in which airway mucus together with substances trapped within are moved out of the lungs, is an important defence mechanism of the human body. Drugs may alter this process, such that it is necessary to know the effect of the drugs on MCC. Indeed, agents stimulating MCC may be used therapeutically in respiratory medicine, especially in patients suspected of having an impairment of their mucociliary transport system. In contrast, caution should be taken with drugs depressing MCC as an undesired side-effect, independently of their therapeutic indication. Since cough clearance (CC) serves as a back-up system when MCC fails, the influence of drugs must be examined not only on MCC but also on CC. Ultimately, the clinical repercussions of alterations in mucus transport induced by drug administration must be studied. Tertiary ammonium compounds (anticholinergics), aspirin, anaesthetic agents and benzodiazepines have been shown to be capable of depressing the mucociliary transport system. Cholinergics, methylxanthines, sodium cromoglycate, hypertonic saline, saline as well as water aerosol have been shown to increase MCC. Adrenergic antagonists, guaifenesin, S-carboxymethylcysteine, sodium 2-mercapto-ethane sulphonate and frusemide have been reported not to alter the mucociliary transport significantly. Amiloride, uridine 5'-triphosphate (UTP), quaternary ammonium compounds (anticholinergics), adrenergic agonists, corticosteroids, recombinant human deoxyribonuclease (rhDNase), N-acetylcysteine, bromhexine and ambroxol have been reported either not to change or to augment MCC. Indirect data suggest that surfactant as well as antibiotics may improve the mucociliary transport system. As for the influence of drugs on CC, amiloride and rhDNase have been demonstrated to increase the effectiveness of cough. A trend towards an improved CC was noted after treatment with adrenergic agonists. The anticholinergic agent ipratropium bromide, which

  8. Radioaerosol lung clearance in patients with active pulmonary sarcoidosis

    SciTech Connect

    Jacobs, M.P.; Baughman, R.P.; Hughes, J.; Fernandez-Ulloa, M.

    1985-05-01

    Pulmonary radioaerosol clearance rate of /sup 99m/Tc diethylenetriamine pentacetate (DTPA) in 14 patients with untreated sarcoidosis was compared with /sup 67/Ga lung scan and increased lymphocytes in the bronchoalveolar lavage (BAL) fluid. Nine healthy nonsmoking subjects had a mean DTPA clearance rate of 1.18%/min (range, 0.54 to 1.60%/min). Eight of 14 patients with sarcoidosis had clearance rates greater than 1.60%/min. Of those 8 patients with abnormal DTPA clearance, 4 had positive gallium scans, 4 had more than 17% lymphocytes in the BAL fluid, and 3 had both tests positive. To study the cause of abnormal DTPA clearance, 23 subjects (including 3 normal controls, all 14 patients with sarcoidosis, and 6 patients with localized disease on chest roentgenogram) underwent both DTPA clearance studies and BAL for quantitation of the amount of albumin in lung fluid. There was a positive correlation between the rate of DTPA clearance and the albumin concentration in lung fluid (r = 0.87, p less than 0.01).

  9. Integrated Turbine Tip Clearance and Gas Turbine Engine Simulation

    NASA Technical Reports Server (NTRS)

    Chapman, Jeffryes W.; Kratz, Jonathan; Guo, Ten-Huei; Litt, Jonathan

    2016-01-01

    Gas turbine compressor and turbine blade tip clearance (i.e., the radial distance between the blade tip of an axial compressor or turbine and the containment structure) is a major contributing factor to gas path sealing, and can significantly affect engine efficiency and operational temperature. This paper details the creation of a generic but realistic high pressure turbine tip clearance model that may be used to facilitate active tip clearance control system research. This model uses a first principles approach to approximate thermal and mechanical deformations of the turbine system, taking into account the rotor, shroud, and blade tip components. Validation of the tip clearance model shows that the results are realistic and reflect values found in literature. In addition, this model has been integrated with a gas turbine engine simulation, creating a platform to explore engine performance as tip clearance is adjusted. Results from the integrated model explore the effects of tip clearance on engine operation and highlight advantages of tip clearance management.

  10. Analysis of viral clearance unit operations for monoclonal antibodies.

    PubMed

    Miesegaes, George; Lute, Scott; Brorson, Kurt

    2010-06-01

    Demonstration of viral clearance is a critical step in assuring the safety of biotechnology products. We generated a viral clearance database that contains product information, unit operation process parameters, and viral clearance data from monoclonal antibody and antibody-related regulatory submissions to FDA. Here we present a broad overview of the database and resulting analyses. We report that the diversity of model viruses tested expands as products transition to late-phase. We also present averages and ranges of viral clearance results by Protein A and ion exchange chromatography steps, low pH chemical inactivation, and virus filtration, focusing on retro- and parvoviruses. For most unit operations, an average log reduction value (LRV, a measure of clearance power) for retrovirus of >4 log(10) were measured. Cases where clearance data fell outside of the anticipated range (i.e., outliers) were rationally explained. Lastly, a historical analysis did not find evidence of any improvement trend in viral clearance over time. The data collectively suggest that many unit operations in general can reliably clear viruses.

  11. Dynamic modelling and experimental study of cantilever beam with clearance

    NASA Astrophysics Data System (ADS)

    Li, B.; Jin, W.; Han, L.; He, Z.

    2012-05-01

    Clearances occur in almost all mechanical systems, typically such as the clearance between slide plate of gun barrel and guide. Therefore, to study the clearances of mechanisms can be very important to increase the working performance and lifetime of mechanisms. In this paper, rigid dynamic modelling of cantilever with clearance was done according to the subject investigated. In the rigid dynamic modelling, clearance is equivalent to the spring-dashpot model, the impact of beam and boundary face was also taken into consideration. In ADAMS software, the dynamic simulation was carried out according to the model above. The software simulated the movement of cantilever with clearance under external excitation. Research found: When the clearance is larger, the force of impact will become larger. In order to study how the stiffness of the cantilever's supporting part influences natural frequency of the system, A Euler beam which is restricted by a draught spring and a torsion spring at its end was raised. Through numerical calculation, the relationship between natural frequency and stiffness was found. When the value of the stiffness is close to the limit value, the corresponding boundary condition is illustrated. An ADAMS experiment was carried out to check the theory and the simulation.

  12. Distribution and clearance of radioactive aerosol on the nasal mucosa.

    PubMed

    McLean, J A; Bacon, J R; Mathews, K P; Thrall, J H; Banas, J M; Hedden, J; Bayne, N K

    1984-03-01

    The distribution and clearance of aerosolized radioactive technetium 99m pertechnate in physiologic buffered saline was analyzed in four human adult asymptomatic volunteers following delivery into one nostril in the same manner as for nasal challenge testing (i.e., 0.1 ml via a 251 DeVilbiss atomizer powered by a compressor delivering 0.10 +/- 0.01 gm/spray). For comparison, squeeze bottles and spray bottles from commercial sources, a 114 and a 127 DeVilbiss atomizer, and a pipette were employed. Lateral imagery via minicomputer processing was used to determine both distribution and clearance of the radiotracer. The counts after 1 minute were lower following pipette delivery than with the other devices. None yielded discernable , wide-spread distribution of aerosol throughout the nasal cavity. Following delivery from the 251 atomizer, mean clearance at 17 minutes was 60.0%. Similar clearance rates were obtained with the other spraying methods except for lower values with the squeeze bottle. Analysis of six hour clearance studies by linear regression showed a relatively rapid initial phase, which is probably due largely to mucociliary clearance, and a prolonged late phase related to the very slow disappearance of residual material located far anteriorly in the nose. Achieving good initial retention and rapid clearance of material deposited anteriorly in the nose are desirable attributes of devices employed for administering materials intranasally.

  13. Baselines representing blood glucose clearance improve in vitro prediction of the glycaemic impact of customarily consumed food quantities.

    PubMed

    Monro, John A; Mishra, Suman; Venn, Bernard

    2010-01-01

    Glycaemic responses to foods reflect the balance between glucose loading into, and its clearance from, the blood. Current in vitro methods for glycaemic analysis do not take into account the key role of glucose disposal. The present study aimed to develop a food intake-sensitive method for measuring the glycaemic impact of food quantities usually consumed, as the difference between release of glucose equivalents (GGE) from food during in vitro digestion and a corresponding estimate of clearance of them from the blood. Five foods - white bread, fruit bread, muesli bar, mashed potato and chickpeas - were consumed on three occasions by twenty volunteers to provide blood glucose response (BGR) curves. GGE release during in vitro digestion of the foods was also plotted. Glucose disposal rates estimated from downward slopes of the BGR curves allowed GGE dose-dependent cumulative glucose disposal to be calculated. By subtracting cumulative glucose disposal from cumulative in vitro GGE release, accuracy in predicting the in vivo glycaemic effect from in vitro GGE values was greatly improved. GGE(in vivo) = 0.99GGE(in vitro)+0.75 (R(2) 0.88). Furthermore, the difference between the curves of cumulative GGE release and disposal closely mimicked in vivo incremental BGR curves. We conclude that valid measurement of the glycaemic impact of foods may be obtained in vitro, and expressed as grams of glucose equivalents per food quantity, by taking account not only of GGE release from food during in vitro digestion, but also of blood glucose clearance in response to the food quantity.

  14. Clearance from the anterior chamber of RBCs from human diabetics

    SciTech Connect

    Williams, G.A.; Hatchell, D.L.; Collier, B.D.; Knobel, J.

    1984-06-01

    Erythrocytes from diabetic patients manifest decreased deformability and increased adherence. These abnormal membrane properties may diminish the ability of erythrocytes (RBCs) from diabetics to undergo deformation in passage through the trabecular meshwork. Using sodium chromate Cr 51-labeled RBCs from type I diabetic patients with proliferative retinopathy and normal control subjects, we studied RBC clearance from the rabbit anterior chamber. The mean time for 50% clearance (T50) of RBCs from diabetics (76 hours) was significantly longer than that for RBCs from normal subjects (19.5 hours). In this model, RBCs from diabetics have a slower clearance from the anterior chamber than do RBCs from normal subjects.

  15. Toward a Fast-Response Active Turbine Tip Clearance Control

    NASA Technical Reports Server (NTRS)

    Melcher, Kevin J.; Kypuros, Javier A.

    2003-01-01

    This paper describes active tip clearance control research being conducted by NASA to improve turbine engine systems. The target application for this effort is commercial aircraft engines. However, technologies developed for clearance control can benefit a broad spectrum of current and future turbomachinery. The first portion of the paper addresses the research from a programmatic viewpoint. Recent studies that provide motivation for the work, identification of key technologies, and NASA's plan for addressing deficiencies in the technologies are discussed. The later portion of the paper drills down into one of the key technologies by presenting equations and results for a preliminary dynamic model of the tip clearance phenomena.

  16. Aerosol Medications for Treatment of Mucus Clearance Disorders.

    PubMed

    Rubin, Bruce K

    2015-06-01

    Airway mucus hypersecretion and secretion retention can result from inflammation, irritation, stimulation, or mucus-producing tumors. Secretion clearance can be furthered hampered by ciliary dysfunction and by weakness or restrictive lung disease, leading to an ineffective cough. There are a number of different mucoactive medications that have been used to reduce hypersecretion, make secretions easier to transport, or increase the efficiency of cough or mucus clearance. In this paper, I review the pathophysiology of secretory hyper-responsiveness and mucus hypersecretion and discuss the different aerosol medications that can be used to augment secretion clearance. PMID:26070577

  17. Time-of-Flight Tip-Clearance Measurements

    NASA Technical Reports Server (NTRS)

    Dhadwal, H. S.; Kurkov, A. P.; Janetzke, D. C.

    1999-01-01

    In this paper a time-of-flight probe system incorporating the two integrated fiber optic probes which are tilted equally relative to the probe holder centerline, is applied for the first time to measure the tip clearance of an advanced fan prototype. Tip clearance is largely independent of the signal amplitude and it relies on timing measurement. This work exposes optical effects associated with the fan blade stagger angle that were absent during the original spin-rig experiment on the zero stagger rotor. Individual blade tip clearances were measured with accuracy of +/- 127-mm (+/- 0.005-in). Probe features are discussed and improvements to the design are suggested.

  18. Aerosol Medications for Treatment of Mucus Clearance Disorders.

    PubMed

    Rubin, Bruce K

    2015-06-01

    Airway mucus hypersecretion and secretion retention can result from inflammation, irritation, stimulation, or mucus-producing tumors. Secretion clearance can be furthered hampered by ciliary dysfunction and by weakness or restrictive lung disease, leading to an ineffective cough. There are a number of different mucoactive medications that have been used to reduce hypersecretion, make secretions easier to transport, or increase the efficiency of cough or mucus clearance. In this paper, I review the pathophysiology of secretory hyper-responsiveness and mucus hypersecretion and discuss the different aerosol medications that can be used to augment secretion clearance.

  19. Metabolic clearance rate and urinary clearance of purified beta-core

    SciTech Connect

    Wehmann, R.E.; Blithe, D.L.; Flack, M.R.; Nisula, B.C. )

    1989-09-01

    We injected a highly purified preparation of the beta-core molecule, a fragment of hCG beta excreted in pregnancy urine, into five men and three women to determine its kinetic parameters, MCR, and urinary clearance. The beta-core molecule was distributed in an initial volume (1950 +/- 156 (mean +/- SEM) mL/m2 body surface area) approximately equal to the estimated plasma volume. Its disappearance was multiexponential on a semilogarithmic plot, with a rapid phase t1/2 of 3.5 +/- 0.7 min and a slow phase t1/2 of 22.4 +/- 4.2 min. The transit time (the mean time spent by a molecule of beta-core in transit) was 20.6 +/- 2.1 min. The MCR was 192.0 +/- 8.0 mL/min.m2 body surface area. About 5% of the injected dose of beta-core was excreted into the urine in the first 30 min after injection, and low levels of excretion persisted for up to 7 days. The urinary clearance rate of beta-core was 13.7 +/- 1.4 mL/min.m2, accounting for about 8% of the elimination of beta-core from the plasma. The beta-core immunoreactivity in serum and urine was characterized by gel filtration and three independent RIA systems to show that its properties were indistinguishable from those of the injected beta-core. Serum levels of beta-core in pregnant women were less than 0.2 ng/mL, while the amounts excreted in their urine were as much as 5 mg/day. Based on these clearance parameters of beta-core in normal subjects, less than 0.2% of the beta-core excreted in pregnancy urine is derived by urinary clearance of plasma beta-core. Therefore, more than 99% of the beta-core excreted in pregnancy urine is derived from beta-core in a compartment separate from plasma. In particular, these data indicate that there is relatively little placental secretion of beta-core into plasma and that placental secretion does not account for the vast majority of beta-core in pregnancy urine.

  20. Intraarticular volume and clearance in human synovial effusions

    SciTech Connect

    Wallis, W.J.; Simkin, P.A.; Nelp, W.B.; Foster, D.M.

    1985-04-01

    Intraarticular volumes were measured by radiolabeled albumin (RISA) distribution in chronic knee effusions from 11 rheumatoid arthritis patients and 9 osteoarthritis patients. Volumes of synovial fluid obtained at joint aspiration were substantially less than those found by RISA dilution. Up to 24 hours was needed for full distribution of RISA throughout the intraarticular compartment. Measured 123I and RISA radioactivity over the knee described monoexponential rate constants, lambda (minute-1). The clearance of 123I and RISA from synovial effusions was derived by the formulation volume (ml) X lambda (minute-1) = clearance (ml/minute). RISA clearance in rheumatoid effusions was significantly greater than that found in osteoarthritis effusions. Intraarticular volume and isotope clearance were easily quantified and provide measures for further evaluating the microvascular physiology of synovial effusions.

  1. IFNL4 affects clearance of hepatitis C virus

    Cancer.gov

    Scientists have discovered a new human interferon gene, Interferon Lambda 4 (IFNL4), that affects clearance of the hepatitis C virus. They also identified an inherited genetic variant within IFNL4 that predicts how people respond to treatment for hepatit

  2. Further Characterization of an Active Clearance Control Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn C.; Steinetz, Bruce M.; Oswald, Jay J.

    2007-01-01

    A new test chamber and precision hydraulic actuation system were incorporated into an active clearance control (ACC) test rig at NASA Glenn Research Center. Using the improved system, a fast-acting, mechanically-actuated, ACC concept was evaluated at engine simulated temperatures and pressure differentials up to 1140 F and 120 psig, on the basis of secondary seal leakage and kinematic controllability. During testing, the ACC concept tracked a simulated flight clearance transient profile at 1140 F, 120 psig, with a maximum error of only 0.0012 in. Comparison of average dynamic leakage of the system with average static leakage did not show significant differences between the two operating conditions. Calculated effective clearance values for the rig were approximately 0.0002 in. at 120 psig, well below the industry specified effective clearance threshold of 0.001 in.

  3. High Temperature Evaluation of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn C.; Steinetz, Bruce M.; Oswald, Jay J.

    2006-01-01

    A mechanically actuated blade tip clearance control concept was evaluated in a nonrotating test rig to quantify secondary seal leakage at elevated temperatures. These tests were conducted to further investigate the feasibility of actively controlling the clearance between the rotor blade tips and the surrounding shroud seal in the high pressure turbine (HPT) section of a turbine engine. The test environment simulates the state of the back side of the HPT shroud seal with pressure differentials as high as 120 psig and temperatures up to 1000 F. As expected, static secondary seal leakage decreased with increasing temperature. At 1000 F, the test rig's calculated effective clearance (at 120 psig test pressure) was 0.0003 in., well within the industry specified effective clearance goal.

  4. 32 CFR 644.516 - Clearance of Air Force lands.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed... Defense requirements, the appropriate DE will obtain a certificate as to the extent of contamination...

  5. 49 CFR 229.71 - Clearance above top of rail.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ..., DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Suspension System § 229.71 Clearance above top of rail. No part or appliance of a locomotive except the wheels,...

  6. Antibody-Mediated Clearance of Alphavirus Infection from Neurons

    NASA Astrophysics Data System (ADS)

    Levine, Beth; Hardwick, J. Marie; Trapp, Bruce D.; Crawford, Thomas O.; Bollinger, Robert C.; Griffin, Diane E.

    1991-11-01

    Humoral immunity is important for protection against viral infection and neutralization of extracellular virus, but clearance of virus from infected tissues is thought to be mediated solely by cellular immunity. However, in a SCID mouse model of persistent alphavirus encephalomyelitis, adoptive transfer of hyperimmune serum resulted in clearance of infectious virus and viral RNA from the nervous system, whereas adoptive transfer of sensitized T lymphocytes had no effect on viral replication. Three monoclonal antibodies to two different epitopes on the E2 envelope glycoprotein mediated viral clearance. Treatment of alphavirus-infected primary cultured rat neurons with these monoclonal antibodies to E2 resulted in decreased viral protein synthesis, followed by gradual termination of mature infectious virion production. Thus, antibody can mediate clearance of alphavirus infection from neurons by restricting viral gene expression.

  7. Enhancement of the amylase-creatinine clearance ratio in pregnancy.

    PubMed

    Naeije, R; Neuray, F; Van Melsen, A; Delcourt, A

    1979-01-01

    The renal clearance of amylase, expressed as a proportion of simultaneous creatinine clearance (Cam/-Ccr), was determined in 131 women in various stages of pregnancy. No abnormal serum levels of amylase were found. A moderate but significant increase in Cam/Ccr occurred during the last 15 weeks of pregnancy. Possible causes for this change were investigated in smaller groups of subjects. No increase in rapidly cleared isoamylase could be detected. No modification in renal tubular handling of protein could be evidenced, as assessed by measurements of the renal clearance of beta 2 microglobulin, expressed as a proportion of simultaneous creatinine clearance. An incrased glomerular permeability to amylase probably accounts for elevated Cam/Ccr in pregnancy.

  8. 32 CFR 644.517 - Clearance of Army lands.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Clearance, the following information will be furnished to the DE upon completion of the neutralization: (a) Records of the neutralization work performed, including statement of methods employed. (b) List...

  9. 32 CFR 644.517 - Clearance of Army lands.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... Clearance, the following information will be furnished to the DE upon completion of the neutralization: (a) Records of the neutralization work performed, including statement of methods employed. (b) List...

  10. 32 CFR 644.517 - Clearance of Army lands.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... Clearance, the following information will be furnished to the DE upon completion of the neutralization: (a) Records of the neutralization work performed, including statement of methods employed. (b) List...

  11. Clearance detector and method for motion and distance

    DOEpatents

    Xavier, Patrick G.

    2011-08-09

    A method for correct and efficient detection of clearances between three-dimensional bodies in computer-based simulations, where one or both of the volumes is subject to translation and/or rotations. The method conservatively determines of the size of such clearances and whether there is a collision between the bodies. Given two bodies, each of which is undergoing separate motions, the method utilizes bounding-volume hierarchy representations for the two bodies and, mappings and inverse mappings for the motions of the two bodies. The method uses the representations, mappings and direction vectors to determine the directionally furthest locations of points on the convex hulls of the volumes virtually swept by the bodies and hence the clearance between the bodies, without having to calculate the convex hulls of the bodies. The method includes clearance detection for bodies comprising convex geometrical primitives and more specific techniques for bodies comprising convex polyhedra.

  12. 32 CFR 644.527 - Recording Statements of Clearance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed..., if possible, as part of the permanent history of the property involved, with the proper county...

  13. 32 CFR 644.527 - Recording Statements of Clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed..., if possible, as part of the permanent history of the property involved, with the proper county...

  14. 32 CFR 644.527 - Recording Statements of Clearance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed..., if possible, as part of the permanent history of the property involved, with the proper county...

  15. 32 CFR 644.527 - Recording Statements of Clearance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed..., if possible, as part of the permanent history of the property involved, with the proper county...

  16. 54. CLEARANCE OF SITE PRIOR TO CONSTRUCTION OF BREAKER BUILDING, ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    54. CLEARANCE OF SITE PRIOR TO CONSTRUCTION OF BREAKER BUILDING, AND CONSTRUCTION OF EMBANKMENT FOR RAILROAD SPUR. c.1898 (AKZO No. A-3) - Avery Island Salt Works, Akzo Salt Incorporated, Avery Island, Iberia Parish, LA

  17. Early Agriculture: Land Clearance and Climate Effects

    NASA Astrophysics Data System (ADS)

    Ruddiman, W. F.

    2013-12-01

    inception. Well-dated high-resolution CO2 (and CH4) records from ice cores show gas decreases that correlate closely with major pandemics and civil strife, but show little if any link to temperature or precipitation trends. One significant (and intriguing) discrepancy with the original hypothesis remains. Most of the CO2 rise occurred between 6000 and 2500 years ago, well before the major increase in global population that has been hindcast from geometric models that assume a constant fractional rate of population increase. Some of this discrepancy has been reconciled by historical evidence showing much higher per-capita clearance millennia ago than later in pre-industrial time, resulting in disproportionately large early clearance and CO2 emissions. In addition, DNA studies and archeological syntheses now indicate that early farming populations initially grew at very fast rates favored by environments rich in basic resources (especially fertile soils), but then slowed in later millennia because of growing resource limitations and the effects of pandemics and civil strife in checking population growth. This emerging view of fast-rising early population trends has the potential to account for the early timing of the CO2 increase.

  18. Airway Clearance Devices for Cystic Fibrosis

    PubMed Central

    2009-01-01

    Executive Summary Objective The purpose of this evidence-based analysis is to examine the safety and efficacy of airway clearance devices (ACDs) for cystic fibrosis and attempt to differentiate between devices, where possible, on grounds of clinical efficacy, quality of life, safety and/or patient preference. Background Cystic fibrosis (CF) is a common, inherited, life-limiting disease that affects multiple systems of the human body. Respiratory dysfunction is the primary complication and leading cause of death due to CF. CF causes abnormal mucus secretion in the airways, leading to airway obstruction and mucus plugging, which in turn can lead to bacterial infection and further mucous production. Over time, this almost cyclical process contributes to severe airway damage and loss of respiratory function. Removal of airway secretions, termed airway clearance, is thus an integral component of the management of CF. A variety of methods are available for airway clearance, some requiring mechanical devices, others physical manipulation of the body (e.g. physiotherapy). Conventional chest physiotherapy (CCPT), through the assistance of a caregiver, is the current standard of care for achieving airway clearance, particularly in young patients up to the ages of six or seven. CF patients are, however, living much longer now than in decades past. The median age of survival in Canada has risen to 37.0 years for the period of 1998-2002 (5-year window), up from 22.8 years for the 5-year window ending in 1977. The prevalence has also risen accordingly, last recorded as 3,453 in Canada in 2002, up from 1,630 in 1977. With individuals living longer, there is a greater need for independent methods of airway clearance. Airway Clearance Devices There are at least three classes of airway clearance devices: positive expiratory pressure devices (PEP), airway oscillating devices (AOD; either handheld or stationary) and high frequency chest compression (HFCC)/mechanical percussion (MP

  19. Langevin Equation on Fractal Curves

    NASA Astrophysics Data System (ADS)

    Satin, Seema; Gangal, A. D.

    2016-07-01

    We analyze random motion of a particle on a fractal curve, using Langevin approach. This involves defining a new velocity in terms of mass of the fractal curve, as defined in recent work. The geometry of the fractal curve, plays an important role in this analysis. A Langevin equation with a particular model of noise is proposed and solved using techniques of the Fα-Calculus.

  20. Calculation of tip clearance effects in a transonic compressor rotor

    NASA Technical Reports Server (NTRS)

    Chima, R. V.

    1996-01-01

    The flow through the tip clearance region of a transonic compressor rotor (NASA rotor 37) was computed and compared to aerodynamic probe and laser anemometer data. Tip clearance effects were modeled both by gridding the clearance gap and by using a simple periodicity model across the ungridded gap. The simple model was run with both the full gap height, and with half the gap height to simulate a vena-contracta effect. Comparisons between computed and measured performance maps and downstream profiles were used to validate the models and to assess the effects of gap height on the simple clearance model. Recommendations were made concerning the use of the simple clearance model. Detailed comparisons were made between the gridded clearance gap solution and the laser anemometer data near the tip at two operating points. The computer results agreed fairly well with the data but overpredicted the extent of the casing separation and underpredicted the wake decay rate. The computations were then used to describe the interaction of the tip vortex, the passage shock, and the casing boundary layer.

  1. Calculation of Tip Clearance Effects in a Transonic Compressor Rotor

    NASA Technical Reports Server (NTRS)

    Chima, R. V.

    1998-01-01

    The flow through the tip clearance region of a transonic compressor rotor (NASA rotor 37) was computed and compared to aerodynamic probe and laser anemometer data. Tip clearance effects were modeled both by gridding the clearance gap and by using a simple periodicity model across the ungridded gap. The simple model was run with both the full gap height, and with half the gap height to simulate a vena-contracta effect. Comparisons between computed and measured performance maps and downstream profiles were used to validate the models and to assess the effects of gap height on the simple clearance model. Recommendations were made concern- ing the use of the simple clearance model Detailed comparisons were made between the gridded clearance gap solution and the laser anemometer data near the tip at two operating points. The computed results agreed fairly well with the data but overpredicted the extent of the casing separation and underpredicted the wake decay rate. The computations were then used to describe the interaction of the tip vortex, the passage shock, and the casing boundary layer.

  2. Long-term clearance from small airways decreases with age.

    PubMed

    Svartengren, M; Falk, R; Philipson, K

    2005-10-01

    The prevalence of respiratory symptoms increases with age. Age has been found to be negatively associated with large airway clearance. The small airways region is considered important for development of airway disease. Clearance after the first 24 h was studied in 46 healthy subjects with a wide age distribution, (mean 42, range 19-81 yrs). All subjects inhaled monodisperse 6 microm Teflon particles labelled with 111In, with an extremely slow inhalation flow (0.05 L.s-1). The particles were mainly deposited in the small conducting airways. Lung retention was measured at 0 and 24 h, and at 7, 14 and 21 days after inhalation. Significant relationships were found for the individual 24 h "large" airway clearance in per cent of initial lung deposition with age, forced expiratory volume in one second and forced vital capacity. Age was negatively associated with "small" airway clearance after 24 h as estimated at 2, 7, 14 and 21 days. Using stepwise linear regression only age remained significantly associated to clearance. In conclusion, small airway clearance over 21 days was found to decrease with age. This might be one factor associated with the high prevalence of respiratory symptoms associated among the elderly.

  3. Urinary and metabolic clearances of arginine vasopressin in normal subjects

    SciTech Connect

    Moses, A.M.; Steciak, E.

    1986-08-01

    Synthetic arginine vasopressin (AVP) was infused into 11 hydrated normal subjects at five different infusion rates ranging from 10 to 350 U kg min . Each infusion rate was continued for 1 h, and urinary determinations were made on the 30- to 60-min specimens during which time there was no further rise in plasma AVP. Urinary AVP concentrations ( U/ml) and excretion rates ( U/min) increased linearly with increasing infusion rates, and the concentration of AVP in urine increased 120 times more rapid than plasma. Urinary and metabolic clearances of AVP also increased linearly with the maximum urinary clearance being 60.6% of the creatinine clearance. The total metabolic clearance of AVP (including urinary clearance) was 17.8 times that of the urinary clearance of AVP alone. These data clarify the relationships between plasma and urinary AVP in normal hydrated subjects during AVP infusion under steady-state conditions and emphasize the potential advantage of measuring urinary AVP as a monitor of endogenous AVP secretion. AVP was measured by radioimmunoassay.

  4. On the relationship between the rate of salivary flow and salivary fluoride clearance.

    PubMed

    Duckworth, Ralph M; Jones, S

    2015-01-01

    The amount of fluoride retained in the mouth following the application of dentifrices, mouthwashes, etc. may be important in determining their anticaries efficacy. In this study we investigated the relationship between the salivary flow rate and salivary fluoride clearance. Ten adults tested six mouthrinses, consisting of aqueous sodium fluoride solutions (0.013, 0.026 mol/l) with and without added sodium chloride (1.28 mol/l) or sucrose (0.44 mol/l), in a randomised order. Prior to each test, subjects swallowed, rinsed for 2 min with 2 ml water and then expectorated into a preweighed container to obtain a measure of initial saliva flow rate. Next, the procedure was repeated using one of the test rinses. Finally, samples of unstimulated whole saliva were collected for up to 3 h after each mouthrinse application and analysed for fluoride. Salivary fluoride concentrations were significantly lower after application of mouthrinses that contained either sucrose or NaCl, both of which compounds markedly enhanced salivary flow, than after the use of corresponding mouthrinses without any additive. Area under the salivary fluoride clearance curve (AUC) values were inversely correlated with salivary flow rate on an individual basis (p < 0.01). The observed behaviour could not be completely attributed to treatment dilution by saliva at the time of application. PMID:25634162

  5. Tool For Making Curved Holes

    NASA Technical Reports Server (NTRS)

    Allard, Robert; Calve, Andrew; Pastreck, Edwin; Padden, Edward

    1992-01-01

    Tool for use in electrical-discharge machining (EDM) guides EDM electrode in making curved holes. Guide rod fits in slot in arm, which moves through arc. Motion drives electrode into workpiece along desired curved path. Electrode burns into workpiece while arm rotates on spindle. Discharge cuts hole of same radius of curvature.

  6. Clearance from cerebrospinal fluid of intrathecally administered beta-endorphin in monkeys

    SciTech Connect

    Lee, V.C.; Burns, R.S.; Dubois, M.; Cohen, M.R.

    1984-05-01

    Five adult male monkeys (Macaca mulatta) weighing 7.1-9.9 kg were given synthetic human beta-endorphin (800 micrograms) and (/sup 14/C)methoxy-inulin (50 microCi) in 400 microliters of normal saline intrathecally. Serial samples of cerebrospinal fluid were drawn through a previously positioned indwelling spinal catheter and were assayed for concentrations of beta-endorphin (determined by radioimmunoassay) and inulin (determined by liquid scintillation counter). Spinal fluid concentrations of beta-endorphin and inulin peaked and declined in a parallel manner. The clearance ratio (calculated from the reciprocal of the ratio of the areas under the respective curves of elimination of the two species) remained remarkably similar from animal to animal, giving a mean value of 1.060 +/- 0.090 (SEM). This ratio, being near unity, suggests that beta-endorphin is eliminated from spinal fluid in a fashion similar to that of inulin, which is removed exclusively by bulk absorption.

  7. Respiratory clearance of aerosolized radioactive solutes of varying molecular weight

    SciTech Connect

    Huchon, G.J.; Montgomery, A.B.; Lipavsky, A.; Hoeffel, J.M.; Murray, J.F.

    1987-05-01

    To determine the influence of varying molecular weight (mol wt) on respiratory clearance of aerosolized solutes, we studied eight radiopharmaceuticals, each administered to four dogs: sodium /sup 99m/Tc pertechnetate (TcO4), /sup 99m/Tc glucoheptonate ((/sup 99m/Tc)GH), 51Cr-ethylenedinitrotetraacetate ((51Cr)EDTA), /sup 99m/Tc diethylenetriaminepentaacetate ((99mTc) DTPA), /sup 111/In diethylenetriaminepentaacetate ((/sup 111/In)DTPA), /sup 67/Ga desferoxaminemesylate ((/sup 67/Ga)DFOM), /sup 99m/Tc dextran ((/sup 99m/Tc)DX) and /sup 111/In transferrin ((/sup 111/In)TF). After aerosolization (0.8 m MMD, 2.4 GSD), clearance was determined for 30 min and then corrected by intravenous injection for nonairspace radioactivity. In-TF clearance (0.11 +/- 0.10%/min) was lower than TcO4 (6.32 +/- 0.62%/min), (/sup 99m/Tc)GH (1.50 +/- 0.37%/min), (/sup 51/Cr)EDTA (2.38 +/- 1.02%/min), (/sup 99m/Tc)DTPA (3.51 +/- 0.40%/min), (/sup 111/In)DTPA (2.35 +/- 0.42%/min), (/sup 67/Ga) DFOM (1.99 +/- 0.49%/min) and (/sup 99m/Tc)DX (1.81 +/- 0.75%/min) clearances (p less than 0.001). TcO4 clearance was higher than others (p less than 0.001). Technetium binding to DX was unsatisfactory; aerosolization caused unbinding from DTPA. We conclude that respiratory clearance of large mol wt solutes within 30 min is negligible and, that clearance of molecules between 347-5099 daltons differs greatly, suggesting that binding and/or intrapulmonary retention affect transfer.

  8. Acute effects of ethanol on renal folate clearance in rats

    SciTech Connect

    Eisenga, B.H.; McMartin, K.E.

    1986-03-05

    Studies of the renal clearance of folic acid in primates demonstrate net reabsorption of folate by a saturable system. The acute administration of ethanol to rats causes a significant increase in urinary folate excretion. The mechanism for this effect is unknown and thus the effect of acute administration of ethanol on the renal absorption and urinary clearance of folate was studied in rats. Folic acid was administered to male Sprague-Dawley rats via continuous intravenous infusion in doses ranging from 3-75 micromoles/kg and renal clearance relative to inulin was determined. The effects of various dose levels of ethanol on these parameters were then determined. At a dose of 15 micromoles/kg, the renal clearance of folate relative to that of inulin was about 0.65 mg/min. At a plasma ethanol level about 100 mg/dl, the renal clearance of folate was not markedly altered. These results suggests that there is net reabsorption of folate in the rat kidney and that moderate doses of ethanol have little effect on renal effect on renal folate reabsorption.

  9. TREM2 deficiency reduces the efficacy of immunotherapeutic amyloid clearance.

    PubMed

    Xiang, Xianyuan; Werner, Georg; Bohrmann, Bernd; Liesz, Arthur; Mazaheri, Fargol; Capell, Anja; Feederle, Regina; Knuesel, Irene; Kleinberger, Gernot; Haass, Christian

    2016-01-01

    Immunotherapeutic approaches are currently the most advanced treatments for Alzheimer's disease (AD). Antibodies against amyloid β-peptide (Aβ) bind to amyloid plaques and induce their clearance by microglia via Fc receptor-mediated phagocytosis. Dysfunctions of microglia may play a pivotal role in AD pathogenesis and could result in reduced efficacy of antibody-mediated Aβ clearance. Recently, heterozygous mutations in the triggering receptor expressed on myeloid cells 2 (TREM2), a microglial gene involved in phagocytosis, were genetically linked to late onset AD Loss of TREM2 reduces the ability of microglia to engulf Aβ. We have now investigated whether loss of TREM2 affects the efficacy of immunotherapeutic approaches. We show that anti-Aβ antibodies stimulate Aβ uptake and amyloid plaque clearance in a dose-dependent manner in the presence or absence of TREM2. However, TREM2-deficient N9 microglial cell lines, macrophages as well as primary microglia showed significantly reduced uptake of antibody-bound Aβ and as a consequence reduced clearance of amyloid plaques. Titration experiments revealed that reduced efficacy of amyloid plaque clearance by Trem2 knockout cells can be compensated by elevating the concentration of therapeutic antibodies. PMID:27402340

  10. Poiseuille flow in curved spaces.

    PubMed

    Debus, J-D; Mendoza, M; Succi, S; Herrmann, H J

    2016-04-01

    We investigate Poiseuille channel flow through intrinsically curved media, equipped with localized metric perturbations. To this end, we study the flux of a fluid driven through the curved channel in dependence of the spatial deformation, characterized by the parameters of the metric perturbations (amplitude, range, and density). We find that the flux depends only on a specific combination of parameters, which we identify as the average metric perturbation, and derive a universal flux law for the Poiseuille flow. For the purpose of this study, we have improved and validated our recently developed lattice Boltzmann model in curved space by considerably reducing discrete lattice effects.

  11. Magnetic Curves in Cosymplectic Manifolds

    NASA Astrophysics Data System (ADS)

    Druţă-Romaniuc, Simona-Luiza; Inoguchi, Jun-ichi; Munteanu, Marian Ioan; Nistor, Ana Irina

    2016-08-01

    In this paper we classify the magnetic trajectories with respect to contact magnetic fields in cosymplectic manifolds of arbitrary dimension. We classify Killing magnetic curves in product spaces M2 × R , recalling also explicit description of magnetic curves in E3 , S2 × R and H2 × R . Finally, we prove a reduction theorem for magnetic curves in the cosymplectic space form M bar 2 n(k) × R , in order to show that the (2n+1)-dimensional case reduces to the 3-dimensional one.

  12. HPT Clearance Control: Intelligent Engine Systems-Phase 1

    NASA Technical Reports Server (NTRS)

    2005-01-01

    The following work has been completed to satisfy the Phase I Deliverables for the "HPT Clearance Control" project under NASA GRC's "Intelligent Engine Systems" program: (1) Need for the development of an advanced HPT ACC system has been very clearly laid out, (2) Several existing and potential clearance control systems have been reviewed, (3) A scorecard has been developed to document the system, performance (fuel burn, range, payload, etc.), thermal, and mechanical characteristics of the existing clearance control systems, (4) Engine size and flight cycle selection for the advanced HPT ACC system has been reviewed with "large engine"/"long range mission" combination showing the most benefit, (5) A scoring criteria has been developed to tie together performance parameters for an objective, data driven comparison of competing systems, and (6) The existing HPT ACC systems have been scored based on this scoring system.

  13. Impaired lipid clearance in patients with previous acute pancreatitis.

    PubMed Central

    Guzmán, S; Nervi, F; Llanos, O; León, P; Valdivieso, V

    1985-01-01

    Fasting serum triglycerides were measured in 52 patients who had sustained an attack of pancreatitis (gall stone related 33, alcoholism six) at least six months earlier. Several patients (23%) had raised fasting serum triglycerides, with a type IV phenotype in all but one patient. The 40 patients with normal fasting serum triglycerides received an oral load of 100 g sunflower oil to compare their clearance of dietary triglycerides with that of a control group of 54 subjects. The clearance of ingested triglycerides was significantly impaired in the patients - irrespective of the presumed aetiological factor, or clinical condition associated with pancreatitis - compared with the clearance in controls. A triglyceride tolerance test is the only way to detect those patients in whom a future attack of pancreatitis may be precipitated by a diet rich in fat, or endogenous over production of triglycerides as after an alcoholic debauch. PMID:4029716

  14. Tumor Presence Induces Global Immune Changes and Enhances Nanoparticle Clearance.

    PubMed

    Kai, Marc P; Brighton, Hailey E; Fromen, Catherine A; Shen, Tammy W; Luft, J Christopher; Luft, Yancey E; Keeler, Amanda W; Robbins, Gregory R; Ting, Jenny P Y; Zamboni, William C; Bear, James E; DeSimone, Joseph M

    2016-01-26

    Long-circulating nanoparticles are essential for increasing tumor accumulation to provide therapeutic efficacy. While it is known that tumor presence can alter the immune system, very few studies have explored this impact on nanoparticle circulation. In this report, we demonstrate how the presence of a tumor can change the local and global immune system, which dramatically increases particle clearance. We found that tumor presence significantly increased clearance of PRINT hydrogel nanoparticles from the circulation, resulting in increased accumulation in the liver and spleen, due to an increase in M2-like macrophages. Our findings highlight the need to better understand interactions between immune status and nanoparticle clearance, and suggest that further consideration of immune function is required for success in preclinical and clinical nanoparticle studies.

  15. Inefficient clearance of myelin debris by microglia impairs remyelinating processes

    PubMed Central

    Lampron, Antoine; Larochelle, Antoine; Laflamme, Nathalie; Préfontaine, Paul; Plante, Marie-Michèle; Sánchez, Maria Gabriela; Yong, V. Wee; Stys, Peter K.; Tremblay, Marie-Ève

    2015-01-01

    An imbalance between remyelinating and demyelinating rates underlies degenerative processes in demyelinating diseases such as multiple sclerosis. An optimal therapeutic strategy would be to stimulate remyelination while limiting demyelination. Although accumulation of myelin debris impairs remyelination, the mechanisms regulating the clearance of such debris by mononuclear phagocytic cells are poorly understood. We demonstrate that after cuprizone intoxication, CCR2-dependent infiltration of mouse bone marrow–derived cells is abundant in demyelinating areas, but that these cells do not impact demyelination. However, in CX3CR1-deficient mice, the clearance of myelin debris by microglia was blocked greatly, affecting the integrity of the axon and myelin sheaths and thus preventing proper remyelination. These results highlight the crucial role played by CX3CR1 in myelin removal and show that there can be no efficient remyelination after a primary demyelinating insult if myelin clearance by microglia is impaired. PMID:25779633

  16. Improving mucociliary clearance in chronic obstructive pulmonary disease.

    PubMed

    Bhowmik, Angshu; Chahal, Kamaljeet; Austin, Gillian; Chakravorty, Indranil

    2009-04-01

    Patients with COPD usually experience mucus hypersecretion as a result of airway inflammation and response to noxious stimuli. These in turn lead to worsening airway resistance, impaired airflow, increased work of breathing, dyspnoea and exercise intolerance. Mucus hypersecretion may also lead to increased exacerbations and poor health related quality of life (HRQL). Institution based pulmonary rehabilitation programs incorporating airway clearance techniques have been shown to improve HRQL, reduce dyspnoea and improve exercise tolerance but are often difficult to provide due to restricted accessibility and resource implications. This review examines the current evidence base and best clinical practice in the area of airway clearance. Mechanical devices such as the flutter valves, positive end expiratory pressure and high frequency chest wall oscillation (HFCWO) may be able to provide the benefits of improved airway clearance in the patient's home potentially with reduced demands on healthcare resources.

  17. Fiber-optic laser Doppler turbine tip clearance probe.

    PubMed

    Büttner, Lars; Pfister, Thorsten; Czarske, Jürgen

    2006-05-01

    A laser Doppler based method for in situ single blade tip clearance measurements of turbomachines with high precision is presented for what we believe is the first time. The sensor is based on two superposed fanlike interference fringe systems generated by two laser wavelengths from a fiber-coupled, passive, and therefore compact measurement head employing diffractive optics. Tip clearance measurements at a transonic centrifugal compressor performed during operation at 50,000 rpm (833 Hz, 586 m/s tip speed) are reported. At these speeds the measured uncertainty of the tip position was less than 20 microm, a factor of 2 more accurate than that of capacitive probes. The sensor offers great potential for in situ and online high-precision tip clearance measurements of metallic and nonmetallic turbine blades. PMID:16642064

  18. Curved characteristics behind blast waves.

    NASA Technical Reports Server (NTRS)

    Laporte, O.; Chang, T. S.

    1972-01-01

    The behavior of nonisentropic flow behind a propagating blast wave is theoretically studied. Exact solutions, expressed in closed form in terms of elementary functions, are presented for three sets of curved characteristicseind a self-similar, strong blast wave.

  19. Parabolic curves in Lie groups

    SciTech Connect

    Pauley, Michael

    2010-05-15

    To interpolate a sequence of points in Euclidean space, parabolic splines can be used. These are curves which are piecewise quadratic. To interpolate between points in a (semi-)Riemannian manifold, we could look for curves such that the second covariant derivative of the velocity is zero. We call such curves Jupp and Kent quadratics or JK-quadratics because they are a special case of the cubic curves advocated by Jupp and Kent. When the manifold is a Lie group with bi-invariant metric, we can relate JK-quadratics to null Lie quadratics which arise from another interpolation problem. We solve JK-quadratics in the Lie groups SO(3) and SO(1,2) and in the sphere and hyperbolic plane, by relating them to the differential equation for a quantum harmonic oscillator00.

  20. Effects of desipramine on norepinephrine clearance in congestive heart failure

    SciTech Connect

    Clemson, B.; Baily, R.G.; Davis, D.; Zelis, R. )

    1990-08-01

    Elevated plasma norepinephrine (NE) in congestive heart failure (CHF) is caused by increased NE spillover and decreased NE clearance. To evaluate the effects of neuronal uptake blockade on NE clearance, we studied NE kinetics during steady-state infusions of (3H)NE, before and after oral desipramine (DMI, 50 mg) in 11 patients with CHF and 8 normal volunteers. Baseline plasma NE was greater in the CHF group (637 +/- 56 vs. 271 +/- 32 pg/ml; P less than 0.001), NE clearance was lower in CHF (1.31 +/- 0.21 vs. 1.94 +/- 0.17 l.min-1.m-2; P = 0.026), and NE spillover was greater in CHF (4.71 +/- 0.78 vs. 3.04 +/- 0.35 nmol.min-1.m-2, P = 0.054). After DMI, plasma NE rose significantly in CHF (778 +/- 67; P = 0.008), and NE clearance decreased further in CHF (0.97 +/- 0.16; P = 0.024), but neither changed in normal subjects. NE spillover did not change in either group. There appears to be an enhanced effect of DMI on NE clearance in CHF patients. Two general mechanisms may be responsible for this finding, an increased concentration of drug, possibly caused by a decreased volume of distribution, and an increased sensitivity of neuronal amine pumps to DMI. Both mechanisms may reflect a more general abnormality of clearance of drugs and hormones related to abnormalities of tissue perfusion in CHF.

  1. Acute exposure to acid fog. Effects on mucociliary clearance

    SciTech Connect

    Laube, B.L.; Bowes, S.M. III; Links, J.M.; Thomas, K.K.; Frank, R. )

    1993-05-01

    Submicrometric sulfuric acid (H2SO4) aerosol can affect mucociliary clearance without eliciting irritative symptoms or changes in pulmonary function. The effect of larger fog droplets containing H2SO4 on mucociliary clearance is unknown. We quantified mucociliary clearance from the trachea (n = 4) and small airways (n = 7) of young healthy male adults after an acute exposure to H2SO4 fog (MMAD = 10.3 microns; pH = 2.0; liquid water content = 481 +/- 65 mg/m3; osmolarity = 30 mOsm). Acid fog (AF) or saline fog (SF) (10.9 microns; 492 +/- 116 mg/m3; 30 mOsm) was administered for 40 min of unencumbered breathing (no mouth-piece) at rest and for 20 min of exercise sufficient to produce oronasal breathing. Fog exposures were followed by a methacholine (MCh) challenge (a measure of airway reactivity) or inhalation of technetium-99M radioaerosol (MMAD = 3.4 microns) on 2 study days each. Changes in symptoms and forced ventilatory function were also assessed. Clearance was quantified from computer-assisted analyses of gamma camera images of the lower respiratory tract in terms of %removal/min of the radiolabel from the trachea 25 min after inhalation and from the outer zone of the right lung after 1.9 to 3 h. Symptoms, forced ventilatory function, and MCh response were unaffected by either fog. Tracheal clearance was more rapid in four of four subjects after AF (0.83 +/- 1.58% removal/min) compared with that after SF (-0.54 +/- 0.85% removal/min). Outer zone clearance was more rapid in six of seven subjects after AF (0.22 +/- 0.15% removal/min) compared with that after SF (0.01 +/- 0.09% removal/min).

  2. Flow over riblet curved surfaces

    NASA Astrophysics Data System (ADS)

    Loureiro, J. B. R.; Silva Freire, A. P.

    2011-12-01

    The present work studies the mechanics of turbulent drag reduction over curved surfaces by riblets. The effects of surface modification on flow separation over steep and smooth curved surfaces are investigated. Four types of two-dimensional surfaces are studied based on the morphometric parameters that describe the body of a blue whale. Local measurements of mean velocity and turbulence profiles are obtained through laser Doppler anemometry (LDA) and particle image velocimetry (PIV).

  3. Effect of atropine on oral clearance of a radiolabeled sulfur colloid

    SciTech Connect

    LaForce, F.M.; Thompson, B.; Trow, R.

    1984-11-01

    Physical clearance is an important oral defense mechanism against gram-negative rods. The authors describe a simple technique that uses commercially available technetium-99m sulfur colloid to measure oral clearance. Technetium-99m sulfur colloid was sprayed into the mouth, and clearance was measured as the percent decrease in radiolabel counts over 2 hours using a radioisotope camera. Results using this technique compared favorably with clearance data using Tc-99m radiolabeled Escherichia coli. Atropine significantly decreased oral clearance rates of the colloid. Decreased clearance may be an important risk factor in the development of gram-negative rod colonization in hospitalized patients. 15 references, 3 figures.

  4. Cochlear microphonic broad tuning curves

    NASA Astrophysics Data System (ADS)

    Ayat, Mohammad; Teal, Paul D.; Searchfield, Grant D.; Razali, Najwani

    2015-12-01

    It is known that the cochlear microphonic voltage exhibits much broader tuning than does the basilar membrane motion. The most commonly used explanation for this is that when an electrode is inserted at a particular point inside the scala media, the microphonic potentials of neighbouring hair cells have different phases, leading to cancelation at the electrodes location. In situ recording of functioning outer hair cells (OHCs) for investigating this hypothesis is exceptionally difficult. Therefore, to investigate the discrepancy between the tuning curves of the basilar membrane and those of the cochlear microphonic, and the effect of phase cancellation of adjacent hair cells on the broadness of the cochlear microphonic tuning curves, we use an electromechanical model of the cochlea to devise an experiment. We explore the effect of adjacent hair cells (i.e., longitudinal phase cancellation) on the broadness of the cochlear microphonic tuning curves in different locations. The results of the experiment indicate that active longitudinal coupling (i.e., coupling with active adjacent outer hair cells) only slightly changes the broadness of the CM tuning curves. The results also demonstrate that there is a π phase difference between the potentials produced by the hair bundle and the soma near the place associated with the characteristic frequency based on place-frequency maps (i.e., the best place). We suggest that the transversal phase cancellation (caused by the phase difference between the hair bundle and the soma) plays a far more important role than longitudinal phase cancellation in the broadness of the cochlear microphonic tuning curves. Moreover, by increasing the modelled longitudinal resistance resulting the cochlear microphonic curves exhibiting sharper tuning. The results of the simulations suggest that the passive network of the organ of Corti determines the phase difference between the hair bundle and soma, and hence determines the sharpness of the

  5. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Tailshaft clearance; bearing weardown. 61.20-23 Section...; bearing weardown. (a) Water lubricated bearings, other than rubber, must be rebushed as follows: (1) Where the propelling machinery is located amidship, the after stern tube bearing must be rebushed when it...

  6. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 46 Shipping 2 2011-10-01 2011-10-01 false Tailshaft clearance; bearing weardown. 61.20-23 Section...; bearing weardown. (a) Water lubricated bearings, other than rubber, must be rebushed as follows: (1) Where the propelling machinery is located amidship, the after stern tube bearing must be rebushed when it...

  7. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 46 Shipping 2 2014-10-01 2014-10-01 false Tailshaft clearance; bearing weardown. 61.20-23 Section...; bearing weardown. (a) Water lubricated bearings, other than rubber, must be rebushed as follows: (1) Where the propelling machinery is located amidship, the after stern tube bearing must be rebushed when it...

  8. Decreased renal clearance of digoxin in chronic congestive heart failure.

    PubMed

    Naafs, M A; van der Hoek, C; van Duin, S; Koorevaar, G; Schopman, W; Silberbusch, J

    1985-01-01

    Renal digoxin clearance was compared in patients suffering from atrial fibrillation with well preserved cardiac function (n = 9; salt intake +/- 170 mmol daily) and patients with chronic congestive heart failure (n = 10; salt intake 50 mmol daily and maintenance treatment with diuretics). There was no difference between the groups concerning digoxin dosage, creatinine clearance, diuresis or sodium excretion in the urine. Digoxin clearance in chronic heart failure proved to be significantly lower than in atrial fibrillation (48 +/- 21 vs 71 +/- 36 ml X min-1, p less than 0.05), and Cdig/Ccreat was similarly reduced at 0.73 +/- 0.15 compared to 1.09 +/- 0.27 (p less than 0.005). Steady state serum digoxin concentration was significantly higher in patients with congestive heart failure (1.44 +/- 0.47 vs 0.87 +/- 0.33 micrograms X 1(-1), p less than 0.01). Chronic congestive heart failure is a state with reduced digoxin clearance by the kidney, which could lead to digoxin intoxication not explicable by overdose, reduced renal function or the effect of interacting drugs. PMID:4007028

  9. 11. MODEL 200 CRANE, GENERAL ARRANGEMENT & CLEARANCES. Colby Steel ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    11. MODEL 200 CRANE, GENERAL ARRANGEMENT & CLEARANCES. Colby Steel & Engineering Company, Vancouver B.C., Seattle, New York. Two elevations and cab plan. No architect noted, drawn by "Gould." Sheet A2, No. 6365. Scale not given. August 10, 1942. "Proposal no. 318." blueline print - United Engineering Company Shipyard, Crane, 2900 Main Street, Alameda, Alameda County, CA

  10. 30 CFR 57.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Clearance for surface equipment. 57.9330 Section 57.9330 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL MINES Loading, Hauling, and Dumping Safety Devices,...

  11. 30 CFR 56.9330 - Clearance for surface equipment.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Clearance for surface equipment. 56.9330 Section 56.9330 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-SURFACE METAL AND NONMETAL MINES Loading, Hauling, and Dumping Safety Devices,...

  12. 33 CFR 118.160 - Vertical clearance gauges.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 33 Navigation and Navigable Waters 1 2012-07-01 2012-07-01 false Vertical clearance gauges. 118.160 Section 118.160 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY... repaired. 33 CFR Ch. I (7-1-12 Edition) Coast Guard, DHS...

  13. Highly fluorescent resorcinarene cavitand nanocapsules with efficient renal clearance.

    PubMed

    Mahadevan, Kalpana; Patthipati, Venkata Suresh; Han, Sangbum; Swanson, R James; Whelan, Eoin C; Osgood, Christopher; Balasubramanian, Ramjee

    2016-08-19

    Nanomaterial based imaging approaches hold substantial promise in addressing current diagnostic and therapeutic challenges. One of the key requirements for the successful clinical translation of nanomaterials is their complete clearance from the body within a reasonable time period preferably via the renal filtration route. This article describes the synthesis of highly fluorescent, water soluble, resorcinarene cavitand nanocapsules and demonstrates their effective renal clearance in mice. The synthesis and functionalization of nanocapsules was accomplished in a one-pot operation via thiol-ene reactions without involving self-assembly, sacrificial templates or emulsions. Water soluble resorcinarene cavitand nanocapsules obtained by this approach were covalently functionalized with Alexa Fluor 750. Highly fluorescent nanocapsules with hydrodynamic diameters of 122 nm and 68 nm and extinction coefficients of 1.3 × 10(9) M(-1) cm(-1) and 1.5 × 10(8) M(-1) cm(-1) respectively were prepared by varying the reaction conditions. The in vivo biodistribution and clearance of these nanocapsules in mice followed by whole-body fluorescence imaging showed that they were both cleared renally within a few hours. Given the inherent encapsulation capabilities of nanocapsules, the renal clearance demonstrated in this work opens up new opportunities for their theranostic applications especially for targeting and treating the urinary tract.

  14. Highly fluorescent resorcinarene cavitand nanocapsules with efficient renal clearance.

    PubMed

    Mahadevan, Kalpana; Patthipati, Venkata Suresh; Han, Sangbum; Swanson, R James; Whelan, Eoin C; Osgood, Christopher; Balasubramanian, Ramjee

    2016-08-19

    Nanomaterial based imaging approaches hold substantial promise in addressing current diagnostic and therapeutic challenges. One of the key requirements for the successful clinical translation of nanomaterials is their complete clearance from the body within a reasonable time period preferably via the renal filtration route. This article describes the synthesis of highly fluorescent, water soluble, resorcinarene cavitand nanocapsules and demonstrates their effective renal clearance in mice. The synthesis and functionalization of nanocapsules was accomplished in a one-pot operation via thiol-ene reactions without involving self-assembly, sacrificial templates or emulsions. Water soluble resorcinarene cavitand nanocapsules obtained by this approach were covalently functionalized with Alexa Fluor 750. Highly fluorescent nanocapsules with hydrodynamic diameters of 122 nm and 68 nm and extinction coefficients of 1.3 × 10(9) M(-1) cm(-1) and 1.5 × 10(8) M(-1) cm(-1) respectively were prepared by varying the reaction conditions. The in vivo biodistribution and clearance of these nanocapsules in mice followed by whole-body fluorescence imaging showed that they were both cleared renally within a few hours. Given the inherent encapsulation capabilities of nanocapsules, the renal clearance demonstrated in this work opens up new opportunities for their theranostic applications especially for targeting and treating the urinary tract. PMID:27378394

  15. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Warning devices for restricted clearances. 57.9306 Section 57.9306 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL...

  16. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Warning devices for restricted clearances. 57.9306 Section 57.9306 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL...

  17. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Warning devices for restricted clearances. 57.9306 Section 57.9306 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL...

  18. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Warning devices for restricted clearances. 57.9306 Section 57.9306 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL...

  19. 30 CFR 57.9306 - Warning devices for restricted clearances.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Warning devices for restricted clearances. 57.9306 Section 57.9306 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR METAL AND NONMETAL MINE SAFETY AND HEALTH SAFETY AND HEALTH STANDARDS-UNDERGROUND METAL AND NONMETAL...

  20. 48 CFR 801.602-76 - Business clearance review.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 48 Federal Acquisition Regulations System 5 2011-10-01 2011-10-01 false Business clearance review. 801.602-76 Section 801.602-76 Federal Acquisition Regulations System DEPARTMENT OF VETERANS AFFAIRS GENERAL DEPARTMENT OF VETERANS AFFAIRS ACQUISITION REGULATION SYSTEM Career Development,...

  1. 75 FR 52798 - State-07, Cryptographic Clearance Records

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-27

    ...: Unclassified. SYSTEM LOCATION: Department of State, 301 4th St., SW., Room 750 Washington, DC 20547. CATEGORIES... From the Federal Register Online via the Government Publishing Office DEPARTMENT OF STATE State-07, Cryptographic Clearance Records Summary: Notice is hereby given that the Department of State proposes to...

  2. Highly fluorescent resorcinarene cavitand nanocapsules with efficient renal clearance

    NASA Astrophysics Data System (ADS)

    Mahadevan, Kalpana; Patthipati, Venkata Suresh; Han, Sangbum; Swanson, R. James; Whelan, Eoin C.; Osgood, Christopher; Balasubramanian, Ramjee

    2016-08-01

    Nanomaterial based imaging approaches hold substantial promise in addressing current diagnostic and therapeutic challenges. One of the key requirements for the successful clinical translation of nanomaterials is their complete clearance from the body within a reasonable time period preferably via the renal filtration route. This article describes the synthesis of highly fluorescent, water soluble, resorcinarene cavitand nanocapsules and demonstrates their effective renal clearance in mice. The synthesis and functionalization of nanocapsules was accomplished in a one-pot operation via thiol-ene reactions without involving self-assembly, sacrificial templates or emulsions. Water soluble resorcinarene cavitand nanocapsules obtained by this approach were covalently functionalized with Alexa Fluor 750. Highly fluorescent nanocapsules with hydrodynamic diameters of 122 nm and 68 nm and extinction coefficients of 1.3 × 109 M‑1 cm‑1 and 1.5 × 108 M‑1 cm‑1 respectively were prepared by varying the reaction conditions. The in vivo biodistribution and clearance of these nanocapsules in mice followed by whole-body fluorescence imaging showed that they were both cleared renally within a few hours. Given the inherent encapsulation capabilities of nanocapsules, the renal clearance demonstrated in this work opens up new opportunities for their theranostic applications especially for targeting and treating the urinary tract.

  3. 48 CFR 952.204-73 - Facility clearance.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... code for the Nuclear Materials Management and Safeguards Reporting System if access to nuclear..., if applicable, appointment of a Materials Control and Accountability Representative; and (7) Access... 48 Federal Acquisition Regulations System 5 2014-10-01 2014-10-01 false Facility clearance....

  4. 32 CFR 644.522 - Clearance of military scrap.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... PROPERTY REAL ESTATE HANDBOOK Disposal Clearance of Explosive Hazards and Other Contamination from Proposed... determining whether scrap metal will be removed should be the safety of persons coming on the land in question and, secondarily, the prevention of accidents resulting from the sale and/or use of the scrap...

  5. Highly fluorescent resorcinarene cavitand nanocapsules with efficient renal clearance

    NASA Astrophysics Data System (ADS)

    Mahadevan, Kalpana; Patthipati, Venkata Suresh; Han, Sangbum; Swanson, R. James; Whelan, Eoin C.; Osgood, Christopher; Balasubramanian, Ramjee

    2016-08-01

    Nanomaterial based imaging approaches hold substantial promise in addressing current diagnostic and therapeutic challenges. One of the key requirements for the successful clinical translation of nanomaterials is their complete clearance from the body within a reasonable time period preferably via the renal filtration route. This article describes the synthesis of highly fluorescent, water soluble, resorcinarene cavitand nanocapsules and demonstrates their effective renal clearance in mice. The synthesis and functionalization of nanocapsules was accomplished in a one-pot operation via thiol-ene reactions without involving self-assembly, sacrificial templates or emulsions. Water soluble resorcinarene cavitand nanocapsules obtained by this approach were covalently functionalized with Alexa Fluor 750. Highly fluorescent nanocapsules with hydrodynamic diameters of 122 nm and 68 nm and extinction coefficients of 1.3 × 109 M-1 cm-1 and 1.5 × 108 M-1 cm-1 respectively were prepared by varying the reaction conditions. The in vivo biodistribution and clearance of these nanocapsules in mice followed by whole-body fluorescence imaging showed that they were both cleared renally within a few hours. Given the inherent encapsulation capabilities of nanocapsules, the renal clearance demonstrated in this work opens up new opportunities for their theranostic applications especially for targeting and treating the urinary tract.

  6. 49 CFR Appendix F to Part 512 - OMB Clearance

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 49 Transportation 6 2011-10-01 2011-10-01 false OMB Clearance F Appendix F to Part 512 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONFIDENTIAL BUSINESS INFORMATION Pt. 512, App. F Appendix F to...

  7. 48 CFR 2452.237-75 - Clearance of contractor personnel.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 48 Federal Acquisition Regulations System 6 2010-10-01 2010-10-01 true Clearance of contractor personnel. 2452.237-75 Section 2452.237-75 Federal Acquisition Regulations System DEPARTMENT OF HOUSING AND...). The Contractor shall provide the GTR with the names and Social Security numbers of all such...

  8. 77 FR 22831 - Agency Information Collection Activities: Emergency Clearance Request

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-17

    ... decision at 76 FR 54700. The current information collection request (ICR) requests approval for the public... for Emergency Clearance When we originally published the banning decision rules at 76 FR 54700, the..., and other incoming documents, or to fulfill requests for reports. This would bottleneck or...

  9. 33 CFR 151.1508 - Revocation of clearance.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ...) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Ballast Water Management for Control of Nonindigenous Species in the Great Lakes and Hudson River § 151.1508 Revocation of clearance. A COTP may request the District Director of Customs...

  10. 33 CFR 151.1508 - Revocation of clearance.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ...) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Ballast Water Management for Control of Nonindigenous Species in the Great Lakes and Hudson River § 151.1508 Revocation of clearance. A COTP may request the District Director of Customs...

  11. 33 CFR 151.1508 - Revocation of clearance.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ...) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Ballast Water Management for Control of Nonindigenous Species in the Great Lakes and Hudson River § 151.1508 Revocation of clearance. A COTP may request the District Director of Customs...

  12. 33 CFR 151.1508 - Revocation of clearance.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ...) POLLUTION VESSELS CARRYING OIL, NOXIOUS LIQUID SUBSTANCES, GARBAGE, MUNICIPAL OR COMMERCIAL WASTE, AND BALLAST WATER Ballast Water Management for Control of Nonindigenous Species in the Great Lakes and Hudson River § 151.1508 Revocation of clearance. A COTP may request the District Director of Customs...

  13. 33 CFR 118.160 - Vertical clearance gauges.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... repaired. 33 CFR Ch. I (7-1-13 Edition) Coast Guard, DHS ... BRIDGES BRIDGE LIGHTING AND OTHER SIGNALS § 118.160 Vertical clearance gauges. (a) When necessary for reasons of safety of navigation, the District Commander may require or authorize the installation...

  14. 33 CFR 118.160 - Vertical clearance gauges.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... repaired. 33 CFR Ch. I (7-1-14 Edition) Coast Guard, DHS ... BRIDGES BRIDGE LIGHTING AND OTHER SIGNALS § 118.160 Vertical clearance gauges. (a) When necessary for reasons of safety of navigation, the District Commander may require or authorize the installation...

  15. The Genesis and Justification of Forms Clearance Procedures.

    ERIC Educational Resources Information Center

    Duncan, Joseph W.; Wallman, Katherine K.

    The central reports clearance authority of the Federal Government is a legislatively sanctioned mechanism for applying constraints on the conduct of statistical and other data gathering activities by Federal Departments and agencies and other research parties funded by Federal government contracts. General recommendations for improving the overall…

  16. Model 200 crane, general arrangement & clearances. Colby Steel & ...

    Library of Congress Historic Buildings Survey, Historic Engineering Record, Historic Landscapes Survey

    Model 200 crane, general arrangement & clearances. Colby Steel & Engineering Company, Vancouver B.C., Seattle, New York. Two elevations and cab plan. No architect noted, drawn by Gould. Sheet A2, no 6365. Scaled not given. August 10, 1942. Proposal no. 318. - United Engineering Company Shipyard, Crane, 2900 Main Street, Alameda, Alameda County, CA

  17. 78 FR 77027 - Overhead Clearance (Air-Draft) Accidents

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-12-20

    ... Federal Register (73 FR 3316). Description of Petition for Rulemaking In its Petition for Rulemaking dated... meeting notice (78 FR 49543, 49544, August 14, 2013) and copy of Task 13-10, Recommendation to Establish... SECURITY Coast Guard 33 CFR Parts 117, 161, and 164 46 CFR Part 4 Overhead Clearance (Air-Draft)...

  18. [Airway clearance techniques in chronic obstructive pulmonary syndrome : 2011 update].

    PubMed

    Opdekamp, C

    2011-09-01

    For many years the airway clearance techniques used in chest physical therapy were assimilated with the singular technique of postural drainage, percussions and vibrations. However the side effects and counter indications and the lack of scientific proof regarding this technique have forced reflection and development of other techniques more comfortable and without deleterious effects. If all these techniques show a high efficiency in terms of improved mucociliary clearance, the literature is unanimous on how little effect these techniques have in the short and the long-term with regards to lung function and arterial blood gases. In view of the scientific literature, it is clear that the airway clearance techniques don't have the same recognition concerning their efficiency in all obstructive pulmonary diseases. As the cornerstone in the management of cystic fibrosis, the efficiency of the bronchial hygiene techniques are in general poorly documented in the management of the non-cystic fibrosis bronchiectasis, bronchitis or emphysema. The use of the chest physical therapy seems more to do with the interpretation of the imagery and symptomatology. The airway clearance techniques should be individualised according to symptoms, the amount of expectorated mucus and the objectives signs of secretions retention or subjective signs of difficulty expectorating secretions with progression of the disease. PMID:22034769

  19. Induction of bilirubin clearance by the constitutive androstane receptor (CAR).

    PubMed

    Huang, Wendong; Zhang, Jun; Chua, Steven S; Qatanani, Mohammed; Han, Yunqing; Granata, Riccarda; Moore, David D

    2003-04-01

    Bilirubin clearance is one of the numerous important functions of the liver. Defects in this process result in jaundice, which is particularly common in neonates. Elevated bilirubin levels can be decreased by treatment with phenobarbital. Because the nuclear hormone receptor constitutive androstane receptor (CAR) mediates hepatic effects of this xenobiotic inducer, we hypothesized that CAR could be a regulator of bilirubin clearance. Activation of the nuclear hormone receptor CAR increases hepatic expression of each of five components of the bilirubin-clearance pathway. This induction is absent in homozygous CAR null mice but is observed in mice expressing human CAR instead of mouse CAR. Pretreatment with xenobiotic inducers markedly increases the rate of clearance of an exogenous bilirubin load in wild-type but not CAR knockout animals. Bilirubin itself can also activate CAR, and mice lacking CAR are defective in clearing chronically elevated bilirubin levels. Unexpectedly, CAR expression is very low in livers of neonatal mice and humans. We conclude that CAR directs a protective response to elevated bilirubin levels and suggest that a functional deficit of CAR activity may contribute to neonatal jaundice. PMID:12644704

  20. Seal Investigations of an Active Clearance Control System Concept

    NASA Technical Reports Server (NTRS)

    Steinetz, Bruce M.; Taylor, Shawn; Oswald, Jay; DeCastro, Jonathan A.

    2006-01-01

    In an effort to improve upon current thermal active clearance control methods, a first generation, fast-acting mechanically actuated, active clearance control system has been designed and installed into a non-rotating test rig. In order to harvest the benefit of tighter blade tip clearances, low-leakage seals are required for the actuated carrier segments of the seal shroud to prevent excessive leakage of compressor discharge (P3) cooling air. The test rig was designed and fabricated to facilitate the evaluation of these types of seals, identify seal leakage sources, and test other active clearance control system concepts. The objective of this paper is to present both experimental and analytical investigations into the nature of the face-seal to seal-carrier interface. Finite element analyses were used to examine face seal contact pressures and edge-loading under multiple loading conditions, varied E-seal positions and two new face seal heights. The analyses indicated that moving the E-seal inward radially and reducing face seal height would lead to more uniform contact conditions between the face seal and the carriers. Lab testing confirmed that moving the balance diameter inward radially caused a decrease in overall system leakage.

  1. 49 CFR Appendix F to Part 512 - OMB Clearance

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 49 Transportation 6 2014-10-01 2014-10-01 false OMB Clearance F Appendix F to Part 512 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONFIDENTIAL BUSINESS INFORMATION Pt. 512, App. F Appendix F to...

  2. 49 CFR Appendix F to Part 512 - OMB Clearance

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 49 Transportation 6 2013-10-01 2013-10-01 false OMB Clearance F Appendix F to Part 512 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONFIDENTIAL BUSINESS INFORMATION Pt. 512, App. F Appendix F to...

  3. Influence of clearance model on numerical simulation of centrifugal pump

    NASA Astrophysics Data System (ADS)

    Wang, Z.; Gao, B.; Yang, L.; Du, W. Q.

    2016-05-01

    Computing models are always simplified to save the computing resources and time. Particularly, the clearance that between impeller and pump casing is always ignored. But the completer model is, the more precise result of numerical simulation is in theory. This paper study the influence of clearance model on numerical simulation of centrifugal pump. We present such influence via comparing performance, flow characteristic and pressure pulsation of two cases that the one of two cases is the model pump with clearance and the other is not. And the results show that the head decreases and power increases so that efficiency decreases after computing with front and back cavities. Then no-leakage model would improve absolute velocity magnitude in order to reach the rated flow rate. Finally, more disturbance induced by front cavity flow and wear-ring flow would change the pressure pulsation of impeller and volute. The performance of clearance flow is important for the whole pump in performance, flow characteristic, pressure pulsation and other respects.

  4. OMB Forms Clearance: Restrictions on Educational Research Plans.

    ERIC Educational Resources Information Center

    Coan, Donald L.

    Forms Clearance standards and regulations are used by the Office of Management and Budget and by the Education Division of the Department of Health, Education and Welfare in order to upgrade the quality of federal data collection, to minimize cost, minimize reporting burden, maximize utility, and to protect the privacy rights of respondents.…

  5. 50 CFR 14.52 - Clearance of imported wildlife.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... 50 Wildlife and Fisheries 1 2014-10-01 2014-10-01 false Clearance of imported wildlife. 14.52 Section 14.52 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE...

  6. 50 CFR 14.52 - Clearance of imported wildlife.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... 50 Wildlife and Fisheries 1 2012-10-01 2012-10-01 false Clearance of imported wildlife. 14.52 Section 14.52 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE...

  7. 50 CFR 14.52 - Clearance of imported wildlife.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... 50 Wildlife and Fisheries 1 2013-10-01 2013-10-01 false Clearance of imported wildlife. 14.52 Section 14.52 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE...

  8. 50 CFR 14.52 - Clearance of imported wildlife.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Clearance of imported wildlife. 14.52 Section 14.52 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE...

  9. 50 CFR 14.53 - Detention and refusal of clearance.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... § 14.93 or § 14.94, or penalties assessed against the importer or exporter under 50 CFR part 11. This... 50 Wildlife and Fisheries 1 2010-10-01 2010-10-01 false Detention and refusal of clearance. 14.53 Section 14.53 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE...

  10. 50 CFR 14.52 - Clearance of imported wildlife.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... 50 Wildlife and Fisheries 1 2011-10-01 2011-10-01 false Clearance of imported wildlife. 14.52 Section 14.52 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR TAKING, POSSESSION, TRANSPORTATION, SALE, PURCHASE, BARTER, EXPORTATION, AND IMPORTATION OF WILDLIFE...

  11. Celllular Uptake and Clearance of TIO2 Nanoparticles

    EPA Science Inventory

    Differential rates of cellular uptake and clearance of engineered nanomaterials may influence the propensity for tissue accumulation under chronic exposure conditions. A retinal pigment epithelial cell line (ARPE-19) was used to investigate 1) if Ti02 (Degussa, P25) nanoparticles...

  12. 23 CFR Appendix B to Part 1327 - OMB Clearance

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 23 Highways 1 2010-04-01 2010-04-01 false OMB Clearance B Appendix B to Part 1327 Highways NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION PROCEDURES FOR PARTICIPATING IN AND RECEIVING INFORMATION FROM THE NATIONAL DRIVER REGISTER PROBLEM DRIVER POINTER SYSTEM Pt....

  13. 19 CFR 122.158 - Other entry and clearance requirements.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 19 Customs Duties 1 2010-04-01 2010-04-01 false Other entry and clearance requirements. 122.158 Section 122.158 Customs Duties U.S. CUSTOMS AND BORDER PROTECTION, DEPARTMENT OF HOMELAND SECURITY; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Flights to and From Cuba § 122.158 Other entry...

  14. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... PERIODIC TESTS AND INSPECTIONS Periodic Tests of Machinery and Equipment § 61.20-23 Tailshaft clearance... the propelling machinery is located amidship, the after stern tube bearing must be rebushed when it is... propelling machinery is located aft, the after stern tube bearing must be rebushed when weardown is 1.6...

  15. 46 CFR 61.20-23 - Tailshaft clearance; bearing weardown.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... PERIODIC TESTS AND INSPECTIONS Periodic Tests of Machinery and Equipment § 61.20-23 Tailshaft clearance... the propelling machinery is located amidship, the after stern tube bearing must be rebushed when it is... propelling machinery is located aft, the after stern tube bearing must be rebushed when weardown is 1.6...

  16. 49 CFR Appendix F to Part 512 - OMB Clearance

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 6 2010-10-01 2010-10-01 false OMB Clearance F Appendix F to Part 512 Transportation Other Regulations Relating to Transportation (Continued) NATIONAL HIGHWAY TRAFFIC SAFETY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION CONFIDENTIAL BUSINESS INFORMATION Pt. 512, App. F Appendix F to...

  17. 19 CFR 148.23 - Examination and clearance of baggage.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Collection of Duties and Taxes § 148.23 Examination and clearance of baggage. (a) Articles free of duty. The... United States may examine and pass, without limitation as to value, the following articles in such baggage or otherwise accompanying such person: (1) All articles which are for the personal or...

  18. 19 CFR 148.23 - Examination and clearance of baggage.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Collection of Duties and Taxes § 148.23 Examination and clearance of baggage. (a) Articles free of duty. The... United States may examine and pass, without limitation as to value, the following articles in such baggage or otherwise accompanying such person: (1) All articles which are for the personal or...

  19. Metabolism of nanomaterials in vivo: blood circulation and organ clearance.

    PubMed

    Wang, Bing; He, Xiao; Zhang, Zhiyong; Zhao, Yuliang; Feng, Weiyue

    2013-03-19

    Before researchers apply nanomaterials (NMs) in biomedicine, they need to understand the blood circulation and clearance profile of these materials in vivo. These qualities determine the balance between nanomaterial-induced activity and unwanted toxicity. NMs have heterogeneous characteristics: they combine the bulk properties of solids with the mobility of molecules, and their highly active contact interfaces exhibit diverse functionalities. Any new and unexpected circulation features and clearance patterns are of great concern in toxicological studies and pharmaceutical screens. A number of studies have reported that NMs can enter the bloodstream directly during their application or indirectly via inhalation, ingestion, and dermal exposure. Due to the small size of NMs, the blood can then transport them throughout the circulation and to many organs where they can be stored. In this Account, we discuss the blood circulation and organ clearance patterns of NMs in the lung, liver, and kidney. The circulation of NMs in bloodstream is critical for delivery of inhalable NMs to extrapulmonary organs, the delivery of injectable NMs, the dynamics of tissue redistribution, and the overall targeting of drug carriers to specific cells and organs. The lung, liver, and kidney are the major distribution sites and target organs for NMs exposure, and the clearance patterns of NMs in these organs are critical for understanding the in vivo fate of NMs. Current studies suggest that multiple factors control the circulation and organ clearance of NMs. The size, shape, surface charge, surface functional groups, and aspect ratio of NMs as well as tissue microstructures strongly influence the circulation of NMs in bloodstream, their site-specific extravasation, and their clearance profiles within organs. Therefore structure design and surface modification can improve biocompatibility, regulate the in vivo metabolism, and reduce the toxicity of NMs. The biophysicochemical interactions

  20. Relative Locality in Curved Spacetime

    NASA Astrophysics Data System (ADS)

    Kowalski-Glikman, Jerzy; Rosati, Giacomo

    2013-07-01

    In this paper we construct the action describing dynamics of the particle moving in curved spacetime, with a nontrivial momentum space geometry. Curved momentum space is the core feature of theories where relative locality effects are present. So far aspects of nonlinearities in momentum space have been studied only for flat or constantly expanding (de Sitter) spacetimes, relying on their maximally symmetric nature. The extension of curved momentum space frameworks to arbitrary spacetime geometries could be relevant for the opportunities to test Planck-scale curvature/deformation of particles momentum space. As a first example of this construction we describe the particle with κ-Poincaré momentum space on a circular orbit in Schwarzschild spacetime, where the contributes of momentum space curvature turn out to be negligible. The analysis of this problem relies crucially on the solution of the soccer ball problem.

  1. Algebraic curves of maximal cyclicity

    NASA Astrophysics Data System (ADS)

    Caubergh, Magdalena; Dumortier, Freddy

    2006-01-01

    The paper deals with analytic families of planar vector fields, studying methods to detect the cyclicity of a non-isolated closed orbit, i.e. the maximum number of limit cycles that can locally bifurcate from it. It is known that this multi-parameter problem can be reduced to a single-parameter one, in the sense that there exist analytic curves in parameter space along which the maximal cyclicity can be attained. In that case one speaks about a maximal cyclicity curve (mcc) in case only the number is considered and of a maximal multiplicity curve (mmc) in case the multiplicity is also taken into account. In view of obtaining efficient algorithms for detecting the cyclicity, we investigate whether such mcc or mmc can be algebraic or even linear depending on certain general properties of the families or of their associated Bautin ideal. In any case by well chosen examples we show that prudence is appropriate.

  2. The clearance kinetics of autologous RhD-positive erythrocytes coated ex vivo with novel recombinant and monoclonal anti-D antibodies

    PubMed Central

    Chapman, G E; Ballinger, J R; Norton, M J; Parry-Jones, D R; Beharry, N A; Cousins, C; Dash, C H; Peters, A M

    2007-01-01

    Anti-D is given routinely to pregnant RhD-negative women to prevent haemolytic disease of the fetus and newborn. To overcome the potential drawbacks associated with plasma-derived products, monoclonal and recombinant forms of anti-D have been developed. The ability of two such antibodies, BRAD-3/5 monoclonal anti-D IgG (MAD) and rBRAD-3/5 recombinant anti-D IgG (RAD), to clear RhD-positive erythrocytes from the circulation was compared using a dual radiolabelling technique. Six RhD-positive males received autologous erythrocytes radiolabelled with 99mTc and 51Cr and coated ex vivo with MAD and RAD. Blood samples were collected up to 1 h following intravenous injection, and percentage dose of radioactivity in the samples determined. Three different levels of coating were used on three separate occasions. No significant differences between MAD and RAD were observed in the initial clearance rate constant at any dose level. The log[activity]-time clearance plots were curved, showing a reduction in the clearance rate constant with time. This reduction was more marked for RAD than for MAD. The results support a dynamic model for the clearance of antibody-coated erythrocytes that may have wider relevance for the therapeutic use of antibodies. PMID:17680827

  3. Potential Energy Curves for CO

    NASA Technical Reports Server (NTRS)

    Tobias, Irwin; Fallon, Robert J.; Vanderslice, Joseph T.

    1960-01-01

    Potential energy curves for the Chi (sup 1) Epsilon (sup plus), alpha (sup 3) II (sub r), alpha prime (sup 3) epsilon (sup plus), d (sup 3) delta, e (sup 3) Epsilon (sup minus), Alpha (sup 1) II, and Beta (sup 1) Epsilon (sup plus), electronic states of the CO molecule have been calculated by the Rydberg-Klein-Rees method. The curve for the A III state will have to bend sharply in the range between 1.9 and 2.1 angstroms or it will have to pass through a maximum to reach the proper dissociation limit.

  4. Curved branes with regular support

    NASA Astrophysics Data System (ADS)

    Antoniadis, Ignatios; Cotsakis, Spiros; Klaoudatou, Ifigeneia

    2016-09-01

    We study spacetime singularities in a general five-dimensional braneworld with curved branes satisfying four-dimensional maximal symmetry. The bulk is supported by an analog of perfect fluid with the time replaced by the extra coordinate. We show that contrary to the existence of finite-distance singularities from the brane location in any solution with flat (Minkowski) branes, in the case of curved branes there are singularity-free solutions for a range of equations of state compatible with the null energy condition.

  5. 19 CFR 122.66 - Clearance or permission to depart denied.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...; DEPARTMENT OF THE TREASURY AIR COMMERCE REGULATIONS Clearance of Aircraft and Permission To Depart § 122.66 Clearance or permission to depart denied. If advance electronic air cargo information is not received...

  6. 75 FR 53012 - Form Submitted to the Office of Management and Budget for Extension of Clearance

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-08-30

    ... From the Federal Register Online via the Government Publishing Office SELECTIVE SERVICE SYSTEM... be obtained upon written request to the Selective Service System, Reports Clearance Officer, 1515... Selective Service System, Reports Clearance Officer, 1515 Wilson Boulevard, Arlington, Virginia...

  7. 77 FR 69658 - Agency Information Collection Activities; Proposed Collection; Comment Request: Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-20

    ... approximately 4,350 respondents will be involved in exploratory, field test, pilot, cognitive, and focus group work conducted under this clearance over the requested 3-year clearance period. The average...

  8. 76 FR 49838 - Proposed Collection; Comment Request for Generic Clearance for the Collection of Qualitative...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-08-11

    ... Qualitative Feedback on Agency Service Delivery AGENCY: Internal Revenue Service (IRS), Treasury. ACTION..., the IRS is soliciting comments concerning Generic Clearance for the Collection of Qualitative Feedback... INFORMATION: Title: Generic Clearance for the Collection of Qualitative Feedback on Agency Service...

  9. 76 FR 45573 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-07-29

    ... Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: Office of the... Request (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service.... SUPPLEMENTARY INFORMATION: Title: Health Information Technology Research Center survey. Abstract:...

  10. 77 FR 19673 - Proposed Collection; Comment Request; Generic Clearance To Conduct Voluntary Customer/Partner...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-02

    ... HUMAN SERVICES National Institutes of Health Proposed Collection; Comment Request; Generic Clearance To... and Budget (OMB) for review and approval. Proposed Collection: Title: Generic Clearance to Conduct... strategy in ] accomplishing reinvention goals is the ability to periodically receive input and...

  11. NEXT Performance Curve Analysis and Validation

    NASA Technical Reports Server (NTRS)

    Saripalli, Pratik; Cardiff, Eric; Englander, Jacob

    2016-01-01

    Performance curves of the NEXT thruster are highly important in determining the thruster's ability in performing towards mission-specific goals. New performance curves are proposed and examined here. The Evolutionary Mission Trajectory Generator (EMTG) is used to verify variations in mission solutions based on both available thruster curves and the new curves generated. Furthermore, variations in BOL and EOL curves are also examined. Mission design results shown here validate the use of EMTG and the new performance curves.

  12. Effect of blueberry juice on clearance of buspirone and flurbiprofen in human volunteers

    PubMed Central

    Hanley, Michael J; Masse, Gina; Harmatz, Jerold S; Cancalon, Paul F; Dolnikowski, Gregory G; Court, Michael H; Greenblatt, David J

    2013-01-01

    Aim The present study evaluated the possibility of drug interactions involving blueberry juice (BBJ) and substrate drugs whose clearance is dependent on cytochromes P4503A (CYP3A) and P4502C9 (CYP2C9). Methods A 50:50 mixture of lowbush and highbush BBJ was evaluated in vitro as an inhibitor of CYP3A activity (hydroxylation of triazolam and dealkylation of buspirone) and of CYP2C9 activity (flurbiprofen hydroxylation) using human liver microsomes. In clinical studies, clearance of oral buspirone and oral flurbiprofen was studied in healthy volunteers with and without co-treatment with BBJ. Results BBJ inhibited CYP3A and CYP2C9 activity in vitro, with 50% inhibitory concentrations (IC50) of less than 2%, but without evidence of mechanism-based (irreversible) inhibition. Grapefruit juice (GFJ) also inhibited CYP3A activity, but inhibitory potency was increased by pre-incubation, consistent with mechanism-based inhibition. In clinical studies, GFJ significantly increased area under the plasma concentration−time curve (AUC) for the CYP3A substrate buspirone. The geometric mean ratio (GMR = AUC with GFJ divided by AUC with water) was 2.12. In contrast, the effect of BBJ (GMR = 1.39) was not significant. In the study of flurbiprofen (CYP2C9 substrate), the positive control inhibitor fluconazole significantly increased flurbiprofen AUC (GMR = 1.71), but BBJ had no significant effect (GMR = 1.03). Conclusion The increased buspirone AUC associated with BBJ is quantitatively small and could have occurred by chance. BBJ has no effect on flurbiprofen AUC. The studies provide no evidence for concern about clinically important pharmacokinetic drug interactions of BBJ with substrate drugs metabolized by CYP3A or CYP2C9. PMID:22943633

  13. Tikhonov adaptively regularized gamma variate fitting to assess plasma clearance of inert renal markers

    PubMed Central

    Puetter, Richard C.; Ling, Lin; Babyn, Paul S.

    2010-01-01

    The Tk-GV model fits Gamma Variates (GV) to data by Tikhonov regularization (Tk) with shrinkage constant, λ, chosen to minimize the relative error in plasma clearance, CL (ml/min). Using 169Yb-DTPA and 99mTc-DTPA (n = 46, 8–9 samples, 5–240 min) bolus-dilution curves, results were obtained for fit methods: (1) Ordinary Least Squares (OLS) one and two exponential term (E1 and E2), (2) OLS-GV and (3) Tk-GV. Four tests examined the fit results for: (1) physicality of ranges of model parameters, (2) effects on parameter values when different data subsets are fit, (3) characterization of residuals, and (4) extrapolative error and agreement with published correction factors. Test 1 showed physical Tk-GV results, where OLS-GV fits sometimes-produced nonphysical CL. Test 2 showed the Tk-GV model produced good results with 4 or more samples drawn between 10 and 240 min. Test 3 showed that E1 and E2 failed goodness-of-fit testing whereas GV fits for t > 20 min were acceptably good. Test 4 showed CLTk-GV clearance values agreed with published CL corrections with the general result that CLE1 > CLE2 > CLTk-GV and finally that CLTk-GV were considerably more robust, precise and accurate than CLE2, and should replace the use of CLE2 for these renal markers. PMID:20865304

  14. Interpolation and Polynomial Curve Fitting

    ERIC Educational Resources Information Center

    Yang, Yajun; Gordon, Sheldon P.

    2014-01-01

    Two points determine a line. Three noncollinear points determine a quadratic function. Four points that do not lie on a lower-degree polynomial curve determine a cubic function. In general, n + 1 points uniquely determine a polynomial of degree n, presuming that they do not fall onto a polynomial of lower degree. The process of finding such a…

  15. Supply Curves of Conserved Energy

    SciTech Connect

    Meier, Alan Kevin

    1982-05-01

    Supply curves of conserved energy provide an accounting framework that expresses the potential for energy conservation. The economic worthiness of a conservation measure is expressed in terms of the cost of conserved energy, and a measure is considered economical when the cost of conserved energy is less than the price of the energy it replaces. A supply curve of conserved energy is independent of energy prices; however, the economical reserves of conserved energy will depend on energy prices. Double-counting of energy savings and error propagation are common problems when estimating conservation potentials, but supply curves minimize these difficulties and make their consequences predictable. The sensitivity of the cost of conserved energy is examined, as are variations in the optimal investment strategy in response to changes in inputs. Guidelines are presented for predicting the consequences of such changes. The conservation supply curve concept can be applied to peak power, water, pollution, and other markets where consumers demand a service rather than a particular good.

  16. Elliptic curves and primality proving

    NASA Astrophysics Data System (ADS)

    Atkin, A. O. L.; Morain, F.

    1993-07-01

    The aim of this paper is to describe the theory and implementation of the Elliptic Curve Primality Proving algorithm. Problema, numeros primos a compositis dignoscendi, hosque in factores suos primos resolvendi, ad gravissima ac utilissima totius arithmeticae pertinere, et geometrarum tum veterum tum recentiorum industriam ac sagacitatem occupavisse, tam notum est, ut de hac re copiose loqui superfluum foret.

  17. Breakpoint chlorination curves of greywater.

    PubMed

    March, J G; Gual, M

    2007-08-01

    A study on chlorination of raw greywater with hypochlorite is reported in this paper. Samples were chlorinated in a variety of conditions, and residual chlorine (Cl2) was measured spectrophotometrically. For each sample, the chlorination curve (chlorine residuals versus chlorine dose) was obtained. Curves showed the typical hump-and-dip profile attributable to the formation and destruction of chloramines. It was observed that, after reactions with strong reductants and chloramines-forming compounds, the remaining organic matter exerted a certain demand of chlorine. The evolution of chlorination curves with addition of ammonia and dodecylbencene sulfonate sodium salt and with dilution of the greywater sample were studied. In addition, chlorination curves at several contact times have been obtained, resulting in slower chlorine decay in the hump zone than in the dip zone. In addition, the decay of coliforms in chlorinated samples was also investigated. It was found that, for a chlorination dosage corresponding to the maximum of the hump zone (average 8.9 mg Cl2/ L), samples were negative in coliforms after 10 to 30 minutes of contact time. After-growth was not observed within 3 days after chlorination. Implications in chlorination treatments of raw greywater can be derived from these results. PMID:17824528

  18. Breakpoint chlorination curves of greywater.

    PubMed

    March, J G; Gual, M

    2007-08-01

    A study on chlorination of raw greywater with hypochlorite is reported in this paper. Samples were chlorinated in a variety of conditions, and residual chlorine (Cl2) was measured spectrophotometrically. For each sample, the chlorination curve (chlorine residuals versus chlorine dose) was obtained. Curves showed the typical hump-and-dip profile attributable to the formation and destruction of chloramines. It was observed that, after reactions with strong reductants and chloramines-forming compounds, the remaining organic matter exerted a certain demand of chlorine. The evolution of chlorination curves with addition of ammonia and dodecylbencene sulfonate sodium salt and with dilution of the greywater sample were studied. In addition, chlorination curves at several contact times have been obtained, resulting in slower chlorine decay in the hump zone than in the dip zone. In addition, the decay of coliforms in chlorinated samples was also investigated. It was found that, for a chlorination dosage corresponding to the maximum of the hump zone (average 8.9 mg Cl2/ L), samples were negative in coliforms after 10 to 30 minutes of contact time. After-growth was not observed within 3 days after chlorination. Implications in chlorination treatments of raw greywater can be derived from these results.

  19. 49 CFR 236.22 - Semaphore signal arm; clearance to other objects.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Semaphore signal arm; clearance to other objects...; clearance to other objects. At least one-half inch clearance shall be provided between semaphore signal arm, and any object that may interfere with its operation....

  20. 48 CFR 1845.506-70 - Responsibilities of the plant clearance officer.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... plant clearance officer. 1845.506-70 Section 1845.506-70 Federal Acquisition Regulations System NATIONAL AERONAUTICS AND SPACE ADMINISTRATION CONTRACT MANAGEMENT GOVERNMENT PROPERTY Support Government Property Administration 1845.506-70 Responsibilities of the plant clearance officer. When plant clearance is not...

  1. 76 FR 24920 - Agency Information Collection Activities: Proposed Collection; Comment Request; Generic Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-03

    ...; Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery AGENCY: National... (Generic ICR): ``Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery...: Generic Clearance for the Collection of Qualitative Feedback on Agency Service Delivery. Abstract:...

  2. 20 CFR 653.501 - Requirements for accepting and processing clearance orders.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... clearance any job order seeking workers to perform agricultural or food processing work before reviewing it... order seeking workers to perform agricultural or food processing work into intrastate clearance unless... perform agricultural or food processing work with interstate clearance unless: (1) The job order meets...

  3. 77 FR 28625 - Comment Request for Information Collection for the Agricultural and Food Processing Clearance...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-15

    ... Food Processing Clearance Order, ETA Form 790, Extension With Revisions, and the Agricultural and Food... employers must use the Agricultural and Food Processing Clearance Order, ETA Form 790, to list the job... Agricultural and Food Processing Clearance Memorandum, ETA Form 795, is used by SWAs to extend job...

  4. A Hybrid Jigsaw Approach to Teaching Renal Clearance Concepts

    PubMed Central

    Pollack, Gary M.

    2009-01-01

    Objectives To evaluate the effectiveness of using a jigsaw cooperative learning approach to teach basic concepts of renal clearance to pharmacy students. Design Students collected information on the mechanisms of renal clearance for a particular drug and proposed a methodology for circumventing a urine drug screen. Attitudinal surveys, an online quiz, and course examinations were used to assess student learning. Assessment The majority of students felt apprehensive toward a group assignment prior to the exercise, and afterwards still preferred individual work over group work. Post-exercise quiz and final examination scores showed students successfully learned the material. Conclusions Students were successful in learning from each other and there was no difference in examination performance compared to years when the technique was not used. In addition, the relative negative experiences of previous group work decreased the subjective attitudes related to the current learning experience. PMID:19564992

  5. Microwave Sensor for Blade Tip Clearance and Structural Health Measurements

    NASA Technical Reports Server (NTRS)

    Woike, Mark R.; Bencic, Timothy J.

    2008-01-01

    The use of microwave based sensors for the health monitoring of rotating machinery is being explored at the NASA Glenn Research Center. The microwave sensor works on the principle of sending a continuous signal towards a rotating component and measuring the reflected signal. The phase shift of the reflected signal is proportional to the distance between the sensor and the component that is being measured. This type of sensor is beneficial in that it has the ability to operate at extremely high temperatures and is unaffected by contaminants that may be present in the rotating machinery. It is intended to use these probes in the hot sections of turbine engines for closed loop turbine clearance control and structural health measurements. Background on the sensors, an overview of their calibration and preliminary results from using them to make blade tip clearance and health measurements on a large axial vane fan will be presented.

  6. Lung-clearance mechanisms following inhalation of acid sulfates

    SciTech Connect

    Wolff, R.K.; Muggenburg, B.A.; Silbaugh, S.A.; Carpenter, R.L.; Rowatt, J.D.; Hill, J.O.

    1982-08-01

    These studies have indicated that acute exposures (1-6 hrs) to sulfuric acid at levels of 0.5 to 1.0 mg/m/sup 3/ can produce impairments in mucous clearance. The impairments can last for up to a week following a 1 hr exposure. These effects and studies by others suggest that high sulfate levels in polluted conditions may be one factor in observed increases of hospital visits for respiratory problems. Long term exposures to elevated levels of sulfates resulting in decreases of clearance could also be an initiating factor in producing chronic obstructive pulmonary disease (COPD). These studies have also shown that it is the larger size fraction (0.6 to 1.0 ..mu..m) of sulfuric acid mist in the urban aerosol which is predominantly responsible for at least the acute effects.

  7. Apoptotic cell clearance: basic biology and therapeutic potential.

    PubMed

    Poon, Ivan K H; Lucas, Christopher D; Rossi, Adriano G; Ravichandran, Kodi S

    2014-03-01

    The prompt removal of apoptotic cells by phagocytes is important for maintaining tissue homeostasis. The molecular and cellular events that underpin apoptotic cell recognition and uptake, and the subsequent biological responses, are increasingly better defined. The detection and disposal of apoptotic cells generally promote an anti-inflammatory response at the tissue level, as well as immunological tolerance. Consequently, defects in apoptotic cell clearance have been linked with various inflammatory diseases and autoimmunity. Conversely, under certain conditions, such as the killing of tumour cells by specific cell-death inducers, the recognition of apoptotic tumour cells can promote an immunogenic response and antitumour immunity. Here, we review the current understanding of the complex process of apoptotic cell clearance in physiology and pathology, and discuss how this knowledge could be harnessed for new therapeutic strategies.

  8. [Amylase-creatinine clearance ratios in burned patients (author's transl)].

    PubMed

    Minaire, Y; Marichy, J; Forichon, J; Motin, J

    1978-09-01

    The amylase/creatinine clearance ratio (ACCR) has been examined every 3 days, in 34 burned patients during the 20 days following the accident. This ratio was often abnormal since it was found increased at least on one occasion, in 75% of these patients, to be compared with 23 and 13% for amylase in serum and urine respectively. In another group of 9 burned patients, the ACCR was monitored for time-period between 10 to 52 days. It was observed that a high frequency in increased ACCR was associated with a fatal outcome. Finally simultaneous measurements of ACCR and of the beta2 microglobulin/creatinine clearance ratio (MCCR) showed that increased ACCR were statistically associated with increased MCCR suggesting a decreased renal tubular reabsorption of low molecular weight proteins in these burned patients.

  9. Gas film lubrication equations for very small clearances

    SciTech Connect

    Sobehart, J.R.; Reyna, L.G.

    1994-05-01

    In the hard disk magnetic recording technology, the slider carrying the magnetic elements is supported above the magnetic disk by a self-acting air bearing, which produces the load support. A lubricating film must support a required load with suitably small frictional energy losses and without introducing undesirable instabilities. Under submicron clearance conditions, gas film flow can not be described with continuum models since the molecular mean free path is not negligible compared with the clearance. Accurate results for the load-carrying capacity of gas films for arbitrary Knudsen number are very important since they strongly influence the design of the flying head slider and, consequently, the performance of the magnetic disk storage unit. Here we generalize the previous lubrication equations for arbitrary Knudsen number, accommodation coefficient and a small inclination of the slider relative to the magnetic disk surface.

  10. Schwann cell autophagy, myelinophagy, initiates myelin clearance from injured nerves.

    PubMed

    Gomez-Sanchez, Jose A; Carty, Lucy; Iruarrizaga-Lejarreta, Marta; Palomo-Irigoyen, Marta; Varela-Rey, Marta; Griffith, Megan; Hantke, Janina; Macias-Camara, Nuria; Azkargorta, Mikel; Aurrekoetxea, Igor; De Juan, Virginia Gutiérrez; Jefferies, Harold B J; Aspichueta, Patricia; Elortza, Félix; Aransay, Ana M; Martínez-Chantar, María L; Baas, Frank; Mato, José M; Mirsky, Rhona; Woodhoo, Ashwin; Jessen, Kristján R

    2015-07-01

    Although Schwann cell myelin breakdown is the universal outcome of a remarkably wide range of conditions that cause disease or injury to peripheral nerves, the cellular and molecular mechanisms that make Schwann cell-mediated myelin digestion possible have not been established. We report that Schwann cells degrade myelin after injury by a novel form of selective autophagy, myelinophagy. Autophagy was up-regulated by myelinating Schwann cells after nerve injury, myelin debris was present in autophagosomes, and pharmacological and genetic inhibition of autophagy impaired myelin clearance. Myelinophagy was positively regulated by the Schwann cell JNK/c-Jun pathway, a central regulator of the Schwann cell reprogramming induced by nerve injury. We also present evidence that myelinophagy is defective in the injured central nervous system. These results reveal an important role for inductive autophagy during Wallerian degeneration, and point to potential mechanistic targets for accelerating myelin clearance and improving demyelinating disease.

  11. [Amylase-creatinine clearance ratios in burned patients (author's transl)].

    PubMed

    Minaire, Y; Marichy, J; Forichon, J; Motin, J

    1978-09-01

    The amylase/creatinine clearance ratio (ACCR) has been examined every 3 days, in 34 burned patients during the 20 days following the accident. This ratio was often abnormal since it was found increased at least on one occasion, in 75% of these patients, to be compared with 23 and 13% for amylase in serum and urine respectively. In another group of 9 burned patients, the ACCR was monitored for time-period between 10 to 52 days. It was observed that a high frequency in increased ACCR was associated with a fatal outcome. Finally simultaneous measurements of ACCR and of the beta2 microglobulin/creatinine clearance ratio (MCCR) showed that increased ACCR were statistically associated with increased MCCR suggesting a decreased renal tubular reabsorption of low molecular weight proteins in these burned patients. PMID:360162

  12. Schwann cell autophagy, myelinophagy, initiates myelin clearance from injured nerves

    PubMed Central

    Gomez-Sanchez, Jose A.; Carty, Lucy; Iruarrizaga-Lejarreta, Marta; Palomo-Irigoyen, Marta; Varela-Rey, Marta; Griffith, Megan; Hantke, Janina; Macias-Camara, Nuria; Azkargorta, Mikel; Aurrekoetxea, Igor; De Juan, Virginia Gutiérrez; Jefferies, Harold B.J.; Aspichueta, Patricia; Elortza, Félix; Aransay, Ana M.; Martínez-Chantar, María L.; Baas, Frank; Mato, José M.; Mirsky, Rhona

    2015-01-01

    Although Schwann cell myelin breakdown is the universal outcome of a remarkably wide range of conditions that cause disease or injury to peripheral nerves, the cellular and molecular mechanisms that make Schwann cell–mediated myelin digestion possible have not been established. We report that Schwann cells degrade myelin after injury by a novel form of selective autophagy, myelinophagy. Autophagy was up-regulated by myelinating Schwann cells after nerve injury, myelin debris was present in autophagosomes, and pharmacological and genetic inhibition of autophagy impaired myelin clearance. Myelinophagy was positively regulated by the Schwann cell JNK/c-Jun pathway, a central regulator of the Schwann cell reprogramming induced by nerve injury. We also present evidence that myelinophagy is defective in the injured central nervous system. These results reveal an important role for inductive autophagy during Wallerian degeneration, and point to potential mechanistic targets for accelerating myelin clearance and improving demyelinating disease. PMID:26150392

  13. Intestinal absorption and blood clearance of L-histidine-related compounds after ingestion of anserine in humans and comparison to anserine-containing diets.

    PubMed

    Kubomura, Daiki; Matahira, Yoshiharu; Masui, Ayano; Matsuda, Hideki

    2009-03-11

    Anserine is a bioactive dipeptide found in muscles and brains of vertebrates, but little is known about the kinetics of its absorption into blood and the clearance after the ingestion of anserine or anserine-containing diets. This study investigated time-dependent changes in the concentrations of l-histidine-related compounds from deproteinized blood. The concentration of anserine peaked and then decreased to zero, whereas the concentration of pi-methylhistidine gradually increased, at which point anserine was not detected. Thus, ingested anserine is absorbed intact in human blood and is hydrolyzed to pi-methylhistidine and beta-alanine by serum and tissue carnosinases. Moreover, the crossover study suggests that there was no significant difference in absorption under curves of anserine between anserine alone and anserine-containing diet, whereas there was significant difference in the peak concentration of anserine. This is the first study to demonstrate intestinal absorption and blood clearance of anserine. PMID:19256552

  14. Surface code—biophysical signals for apoptotic cell clearance

    NASA Astrophysics Data System (ADS)

    Biermann, Mona; Maueröder, Christian; Brauner, Jan M.; Chaurio, Ricardo; Janko, Christina; Herrmann, Martin; Muñoz, Luis E.

    2013-12-01

    Apoptotic cell death and the clearance of dying cells play an important and physiological role in embryonic development and normal tissue turnover. In contrast to necrosis, apoptosis proceeds in an anti-inflammatory manner. It is orchestrated by the timed release and/or exposure of so-called ‘find-me’, ‘eat me’ and ‘tolerate me’ signals. Mononuclear phagocytes are attracted by various ‘find-me’ signals, including proteins, nucleotides, and phospholipids released by the dying cell, whereas the involvement of granulocytes is prevented via ‘stay away’ signals. The exposure of anionic phospholipids like phosphatidylserine (PS) by apoptotic cells on the outer leaflet of the plasma membrane is one of the main ‘eat me’ signals. PS is recognized by a number of innate receptors as well as by soluble bridging molecules on the surface of phagocytes. Importantly, phagocytes are able to discriminate between viable and apoptotic cells both exposing PS. Due to cytoskeleton remodeling PS has a higher lateral mobility on the surfaces of apoptotic cells thereby promoting receptor clustering on the phagocyte. PS not only plays an important role in the engulfment process, but also acts as ‘tolerate me’ signal inducing the release of anti-inflammatory cytokines by phagocytes. An efficient and fast clearance of apoptotic cells is required to prevent secondary necrosis and leakage of intracellular danger signals into the surrounding tissue. Failure or prolongation of the clearance process leads to the release of intracellular antigens into the periphery provoking inflammation and development of systemic inflammatory autoimmune disease like systemic lupus erythematosus. Here we review the current findings concerning apoptosis-inducing pathways, important players of apoptotic cell recognition and clearance as well as the role of membrane remodeling in the engulfment of apoptotic cells by phagocytes.

  15. Respiratory Protection Program medical clearance for respirator use

    NASA Technical Reports Server (NTRS)

    1993-01-01

    Background on occupational exposure to various inhalents is discussed including on-site hazard control measures, procedures, physiological effects, and interpretation of results for the medical clearance of employee for use of personal respiratory protection devices. The purpose of the Respiratory Protection Program at LeRC is outlined, and the specifics of the Medical Surveillance Program for Respiratory Protection at LeRC are discussed.

  16. Dysregulation of Nutrient Sensing and CLEARance in Presenilin Deficiency

    PubMed Central

    Reddy, Kavya; Cusack, Corey L.; Nnah, Israel C.; Khayati, Khoosheh; Saqcena, Chaitali; Huynh, Tuong B.; Noggle, Scott A.; Ballabio, Andrea; Dobrowolski, Radek

    2016-01-01

    Summary Attenuated auto-lysosomal system has been associated with Alzheimer disease (AD), yet all underlying molecular mechanisms leading to this impairment are unknown. We show that the amino acid sensing of mechanistic target of rapamycin complex 1 (mTORC1) is dysregulated in cells deficient in presenilin, a protein associated with AD. In these cells, mTORC1 is constitutively tethered to lysosomal membranes, unresponsive to starvation, and inhibitory to TFEB-mediated clearance due to a reduction in Sestrin2 expression. Normalization of Sestrin2 levels through overexpression or elevation of nuclear calcium rescued mTORC1 tethering and initiated clearance. While CLEAR network attenuation in vivo results in buildup of amyloid, phospho-Tau, and neurodegeneration, presenilin-knockout fibroblasts and iPSC-derived AD human neurons fail to effectively initiate autophagy. These results propose an altered mechanism for nutrient sensing in presenilin deficiency and underline an importance of clearance pathways in the onset of AD. PMID:26923592

  17. Turbine Engine Clearance Control Systems: Current Practices and Future Directions

    NASA Technical Reports Server (NTRS)

    Lattime, Scott B.; Steinetz, Bruce M.

    2002-01-01

    Improved blade tip sealing in the high pressure compressor (HPC) and high pressure turbine (HPT) can provide dramatic reductions in specific fuel consumption (SFC), time-on-wing, compressor stall margin, and engine efficiency as well as increased payload and mission range capabilities. Maintenance costs to overhaul large commercial gas turbine engines can easily exceed $1M. Engine removal from service is primarily due to spent exhaust gas temperature (EGT) margin caused mainly by the deterioration of HPT components. Increased blade tip clearance is a major factor in hot section component degradation. As engine designs continue to push the performance envelope with fewer parts and the market drives manufacturers to increase service life, the need for advanced sealing continues to grow. A review of aero gas turbine engine HPT performance degradation and the mechanisms that promote these losses are discussed. Benefits to the HPT due to improved clearance management are identified. Past and present sealing technologies are presented along with specifications for next generation engine clearance control systems.

  18. Smoking produced mucus and clearance of particulates in the lung

    SciTech Connect

    Sterling, T.D.; Poland, T.M.

    1992-12-31

    Some studies of miners have shown a lesser relative lung-cancer risk for smokers than for nonsmokers. For example, experiments by Cross and associates with dogs have shown an apparent protective effect of cigarette smoke against radon-daughter and dust exposure. One reason for these changes may be the thickened mucus layer in the tracheobronchial region of smokers. Physiological changes in the lung due to smoking may decrease the effects of radioactive particles in cancers in the bronchial region by apparently promoting faster clearance, in that region, of radioactive particles and by decreasing the radiation dose through reduced penetration to the sensitive basal epithelial cells. Because of the short half-life of radon daughters, even if there is possible tobacco-related delay of particle clearance from the alveolar region it cannot affect radon clearance. Therefore, the possible mitigating effect of tobacco on radon-produced cancer appears to be limited to the tracheobronchial region. It would be of value to a number of occupations if the same changes in the lungs due to smoking could be produced in exposed workers in the absence of cigarette-smoking. Beta-carotene and vitamin A, which affect maintenance and secretion of the mucosal lining, appear to thicken mucus, thereby providing protection against radon-induced lung cancers that is similar to smoking-related changes in the lung.

  19. Rate-Based Model Predictive Control of Turbofan Engine Clearance

    NASA Technical Reports Server (NTRS)

    DeCastro, Jonathan A.

    2006-01-01

    An innovative model predictive control strategy is developed for control of nonlinear aircraft propulsion systems and sub-systems. At the heart of the controller is a rate-based linear parameter-varying model that propagates the state derivatives across the prediction horizon, extending prediction fidelity to transient regimes where conventional models begin to lose validity. The new control law is applied to a demanding active clearance control application, where the objectives are to tightly regulate blade tip clearances and also anticipate and avoid detrimental blade-shroud rub occurrences by optimally maintaining a predefined minimum clearance. Simulation results verify that the rate-based controller is capable of satisfying the objectives during realistic flight scenarios where both a conventional Jacobian-based model predictive control law and an unconstrained linear-quadratic optimal controller are incapable of doing so. The controller is evaluated using a variety of different actuators, illustrating the efficacy and versatility of the control approach. It is concluded that the new strategy has promise for this and other nonlinear aerospace applications that place high importance on the attainment of control objectives during transient regimes.

  20. Applying Organ Clearance Concepts in a Clinical Setting

    PubMed Central

    2008-01-01

    Objective To teach doctor of pharmacy (PharmD) students how to apply organ clearance concepts in a clinical setting in order to optimize dose management, select the right drug product, and promote better patient-centered care practices. Design A student-focused 5-hour topic entitled "Organ Clearance Concepts: Modeling and Clinical Applications" was developed and delivered to second-year PharmD students. Active-learning techniques, such as reading assignments and thought-provoking questions, and collaborative learning techniques, such as small groups, were used. Student learning was assessed using application cards and a minute paper. Assessment Overall student responses to topic presentation were overwhelmingly positive. The teaching strategies here discussed allowed students to play an active role in their own learning process and provided the necessary connection to keep them motivated, as mentioned in the application cards and minute paper assessments. Students scored an average of 88% on the examination given at the end of the course. Conclusion By incorporating active-learning and collaborative-learning techniques in presenting material on organ clearance concept, students gained a more thorough knowledge of dose management and drug-drug interactions than if the concepts had been presented using a traditional lecture format. This knowledge will help students in solving critical patient situations in a real-world context. PMID:19214275

  1. RAB24 facilitates clearance of autophagic compartments during basal conditions

    PubMed Central

    Ylä-Anttila, Päivi; Mikkonen, Elisa; Happonen, Kaisa E; Holland, Petter; Ueno, Takashi; Simonsen, Anne; Eskelinen, Eeva-Liisa

    2015-01-01

    RAB24 belongs to a family of small GTPases and has been implicated to function in autophagy. Here we confirm the intracellular localization of RAB24 to autophagic vacuoles with immuno electron microscopy and cell fractionation, and show that prenylation and guanine nucleotide binding are necessary for the targeting of RAB24 to autophagic compartments. Further, we show that RAB24 plays a role in the maturation and/or clearance of autophagic compartments under nutrient-rich conditions, but not during short amino acid starvation. Quantitative electron microscopy shows an increase in the numbers of late autophagic compartments in cells silenced for RAB24, and mRFP-GFP-LC3 probe and autophagy flux experiments indicate that this is due to a hindrance in their clearance. Formation of autophagosomes is shown to be unaffected by RAB24-silencing with siRNA. A defect in aggregate clearance in the absence of RAB24 is also shown in cells forming polyglutamine aggregates. This study places RAB24 function in the termination of the autophagic process under nutrient-rich conditions. PMID:26325487

  2. Automatic Detection of Clearance in Mechanical Systems: Experimental Validation

    NASA Astrophysics Data System (ADS)

    Stein, Jeffrey L.; Wang, Churn-Hway

    1996-07-01

    The performance of servosystems with gears (e.g. machine tool drive systems) depends on the clearance or backlash between the gear teeth. Too little and the gears cannot accommodate lubrication and manufacturing errors. Too much and the system accuracy and stability degrade. Therefore, to ensure that a machine system with gears is operating within specifications, the backlash magnitude should be checked frequently. A technique to estimate the backlash automatically is required. The objective of this paper is to evaluate experimentally a clearance detection technique, previously published by the authors, to detect backlash in a servosystem with gears. The technique estimates the backlash by computing the speed variations induced into the primary gear speed by the gear tooth impacts caused by exciting the system sinusoidally. It is shown that a low-cost conventional tachometer is sufficient to measure the induced speed variations. The estimates are shown to represent accurately the actual backlash for ranges 100% of the recommended backlash setting. In addition, by exciting the system with a sinusoid having a DC offset, it is shown that, in a simple one step automatic procedure, the backlash can be averaged over all the gear tooth combinations or computed for individual gear tooth pairs. The results, along with the previously developed theory, indicate that this clearance detection can be inexpensively applied to many machine systems.

  3. Active Piezoelectric Structures for Tip Clearance Management Assessed

    NASA Technical Reports Server (NTRS)

    1995-01-01

    Managing blade tip clearance in turbomachinery stages is critical to developing advanced subsonic propulsion systems. Active casing structures with embedded piezoelectric actuators appear to be a promising solution. They can control static and dynamic tip clearance, compensate for uneven deflections, and accomplish electromechanical coupling at the material level. In addition, they have a compact design. To assess the feasibility of this concept and assist the development of these novel structures, the NASA Lewis Research Center developed in-house computational capabilities for composite structures with piezoelectric actuators and sensors, and subsequently used them to simulate candidate active casing structures. The simulations indicated the potential of active casings to modify the blade tip clearance enough to improve stage efficiency. They also provided valuable design information, such as preliminary actuator configurations (number and location) and the corresponding voltage patterns required to compensate for uneven casing deformations. An active ovalization of a casing with four discrete piezoceramic actuators attached on the outer surface is shown. The center figure shows the predicted radial displacements along the hoop direction that are induced when electrostatic voltage is applied at the piezoceramic actuators. This work, which has demonstrated the capabilities of in-house computational models to analyze and design active casing structures, is expected to contribute toward the development of advanced subsonic engines.

  4. Nonpharmacologic airway clearance techniques in hospitalized patients: a systematic review.

    PubMed

    Andrews, Jeff; Sathe, Nila A; Krishnaswami, Shanthi; McPheeters, Melissa L

    2013-12-01

    Nonpharmacologic airway clearance techniques are used to reduce the sequelae of obstructive secretions. We systematically reviewed comparative studies of nonpharmacologic interventions that health professionals can employ to achieve mucus clearance in hospitalized or postoperative patients without cystic fibrosis, over the age of 12 months. We searched MEDLINE and other databases from 1990 to 2012 to identify relevant literature. Two reviewers independently assessed each study against predetermined inclusion/exclusion criteria. Two reviewers also independently extracted data regarding subject and intervention characteristics and outcomes, and assigned overall quality ratings. The 32 studies meeting the review criteria included 24 randomized controlled trials, 7 crossover randomized controlled trials, and one prospective cohort study. Studies were typically small and together included a total of 2,453 subjects (mean 76/study). Studies generally examined chest physical therapy/physiotherapy modalities in postoperative or critically ill subjects or those with COPD. Interventions, comparators, and populations varied considerably across studies, hampering our ability to draw firm conclusions. Interventions, including conventional chest physical therapy/physiotherapy, intrapulmonary percussive ventilation, and positive expiratory pressure, typically provided small benefits in pulmonary function, gas exchange, oxygenation, and need for/duration of ventilation, among other outcomes, but differences between groups were generally small and not significant. Harms of the techniques were not consistently reported, though airway clearance techniques were generally considered safe in studies that did comment on adverse effects. Further research with clearly characterized populations and interventions is needed to understand the potential benefits and harms of these techniques. PMID:24222708

  5. Dynamic Studies of Lung Fluid Clearance with Phase Contrast Imaging

    SciTech Connect

    Kitchen, Marcus J.; Williams, Ivan; Irvine, Sarah C.; Morgan, Michael J.; Paganin, David M.; Lewis, Rob A.; Pavlov, Konstantin; Hooper, Stuart B.; Wallace, Megan J.; Siu, Karen K. W.; Yagi, Naoto; Uesugi, Kentaro

    2007-01-19

    Clearance of liquid from the airways at birth is a poorly understood process, partly due to the difficulties of observing and measuring the distribution of air within the lung. Imaging dynamic processes within the lung in vivo with high contrast and spatial resolution is therefore a major challenge. However, phase contrast X-ray imaging is able to exploit inhaled air as a contrast agent, rendering the lungs of small animals visible due to the large changes in the refractive index at air/tissue interfaces. In concert with the high spatial resolution afforded by X-ray imaging systems (<100 {mu}m), propagation-based phase contrast imaging is ideal for studying lung development. To this end we have utilized intense, monochromatic synchrotron radiation, together with a fast readout CCD camera, to study fluid clearance from the lungs of rabbit pups at birth. Local rates of fluid clearance have been measured from the dynamic sequences using a single image phase retrieval algorithm.

  6. Comparison of Two Alternate Methods for Tracking Toe Clearance

    NASA Technical Reports Server (NTRS)

    Miller, Christopher A.; Feiveson, Alan H.; Bloomberg, Jacob J.

    2007-01-01

    Analyses of toe clearance during the swing phase of locomotion has often been utilized in determining a subject s propensity to trip while either walking or stepping over an obstacle. In the literature, toe clearance has been studied using a marker on the superior aspect of the second toe (rtoe), a marker on the lateral aspect of the fifth metatarsal head (mth5), or a virtual marker positioned at the anterior tip of the toe (vtoe). The purpose of this study was to compute toe clearance and associated parameters using a fifth metatarsal marker and a virtual toe marker, and compare the results with those of the standard toe marker. Subjects walked on a motorized treadmill at five different speeds while performing a visual acuity task at two separate target distances (ten 60-second trials). The minimum vertical height (TCl) was determined for each stride, along with its point of occurence in the gait cycle, and the angles of the foot and ankle at that time. A regression analysis was performed on the vtoe and mth5 results versus rtoe individually. For all TCl parameters, the mth5 marker did not correlate well with rtoe; the vtoe marker showed better agreement. Most importantly, the mth5 marker predicted a later occurence of TCl than rtoe and vtoe - thereby missing the most dangerous point in swing phase for a trip. From this analysis, the vtoe marker proved to be a better analog to rtoe than mth5, especially for determining a subject s propensity to trip.

  7. Differentially regulated gene expression associated with hepatitis C virus clearance

    PubMed Central

    Grimes, Carolyn Z.; Hwang, Lu-Yu; Wei, Peng; Shah, Dimpy P.; Volcik, Kelly A.

    2013-01-01

    Human chronic hepatitis C virus (HCV) infections pose a significant public health threat, necessitating the development of novel treatments and vaccines. HCV infections range from spontaneous resolution to end-stage liver disease. Approximately 10–30 % of HCV infections undergo spontaneous resolution independent of treatment by yet-to-be-defined mechanisms. These individuals test positive for anti-HCV antibodies in the absence of detectable viral serum RNA. To identify genes associated with HCV clearance, this study compared gene expression profiles between current drug users chronically infected with HCV and drug users who cleared their HCV infection. This analysis identified 91 differentially regulated (up- or downregulated by twofold or more) genes potentially associated with HCV clearance. The majority of genes identified were associated with immune function, with the remaining genes categorized either as cancer related or ‘other’. Identification of factors and pathways that may influence virus clearance will be essential to the development of novel treatment strategies. PMID:23152368

  8. Regulation of mucociliary clearance in health and disease.

    PubMed

    Houtmeyers, E; Gosselink, R; Gayan-Ramirez, G; Decramer, M

    1999-05-01

    Airway secretions are cleared by mucociliary clearance (MCC), in addition to other mechanisms such as cough, peristalsis, two-phase gas-liquid flow and alveolar clearance. MCC comprises the cephalad movement of mucus caused by the cilia lining the conducting airways until it can be swallowed or expectorated. MCC is a very complex process in which many variables are involved, all of which may modify the final outcome. The structure, number, movement and co-ordination of the cilia present in the airways as well as the amount, composition and rheological properties of the periciliary and mucus layers are determinants of MCC. Physiological factors such as age, sex, posture, sleep and exercise are reported to influence MCC due to a change in the cilia, the mucus or the periciliary layer, or a combination of these. Environmental pollution is suspected to have a depressant effect on MCC dependent on different factors such as pollutant concentration and the duration of exposure. Most studies focus on sulphur dioxide, sulphuric acid, nitrogen dioxide and ozone. Tobacco smoke and hairspray have been noted to have a negative influence on MCC. Some diseases are known to affect MCC, mostly negatively. The underlying mechanism differs from one illness to another. Immotile cilia syndrome, asthma, bronchiectasis, chronic bronchitis, cystic fibrosis and some acute respiratory tract infections are among the most frequently reported. The present paper reviews normal mucociliary clearance and the effects of diseases on this process.

  9. Analysis of Exoplanet Light Curves

    NASA Astrophysics Data System (ADS)

    Erdem, A.; Budding, E.; Rhodes, M. D.; Püsküllü, Ç.; Soydugan, F.; Soydugan, E.; Tüysüz, M.; Demircan, O.

    2015-07-01

    We have applied the close binary system analysis package WINFITTER to a variety of exoplanet transiting light curves taken both from the NASA Exoplanet Archive and our own ground-based observations. WINFitter has parameter options for a realistic physical model, including gravity brightening and structural parameters derived from Kopal's applications of the relevant Radau equation, and it includes appropriate tests for determinacy and adequacy of its best fitting parameter sets. We discuss a number of issues related to empirical checking of models for stellar limb darkening, surface maculation, Doppler beaming, microvariability, and transit time variation (TTV) effects. The Radau coefficients used in the light curve modeling, in principle, allow structural models of the component stars to be tested.

  10. Quantum walking in curved spacetime

    NASA Astrophysics Data System (ADS)

    Arrighi, Pablo; Facchini, Stefano; Forets, Marcelo

    2016-08-01

    A discrete-time quantum walk (QW) is essentially a unitary operator driving the evolution of a single particle on the lattice. Some QWs admit a continuum limit, leading to familiar PDEs (e.g., the Dirac equation). In this paper, we study the continuum limit of a wide class of QWs and show that it leads to an entire class of PDEs, encompassing the Hamiltonian form of the massive Dirac equation in (1+1) curved spacetime. Therefore, a certain QW, which we make explicit, provides us with a unitary discrete toy model of a test particle in curved spacetime, in spite of the fixed background lattice. Mathematically, we have introduced two novel ingredients for taking the continuum limit of a QW, but which apply to any quantum cellular automata: encoding and grouping.

  11. Flow Through Randomly Curved Manifolds

    PubMed Central

    Mendoza, M.; Succi, S.; Herrmann, H. J.

    2013-01-01

    We present a computational study of the transport properties of campylotic (intrinsically curved) media. It is found that the relation between the flow through a campylotic media, consisting of randomly located curvature perturbations, and the average Ricci scalar of the system, exhibits two distinct functional expressions, depending on whether the typical spatial extent of the curvature perturbation lies above or below the critical value maximizing the overall scalar of curvature. Furthermore, the flow through such systems as a function of the number of curvature perturbations is found to present a sublinear behavior for large concentrations, due to the interference between curvature perturbations leading to an overall less curved space. We have also characterized the flux through such media as a function of the local Reynolds number and the scale of interaction between impurities. For the purpose of this study, we have also developed and validated a new lattice Boltzmann model. PMID:24173367

  12. Light curves of faint meteors

    NASA Astrophysics Data System (ADS)

    Koten, Pavel; Borovička, Jiří

    2001-11-01

    The results of the light curves analysis of 234 meteors observed and recorded within the double-station image intensifier observations at the Ondřejov observatory are presented. Double-station observations allow to compute the meteor trajectory in the solar system and in the atmosphere as well as to determinate the absolute magnitude of meteor and its mass. Light curves and heights data of all major meteor showers - Lyrids, η-Aquarids, Perseids, Orionids, Leonids, Geminids as well as many sporadic meteors - were analysed. The differences between individual showers were found, e.g. Perseids appear to be more compact than Leonids. There is also difference between 1998 and 1999 Leonids. This suggests different composition or structure of parent bodies. Our data show that the beginning heights of Perseids, Orionids and Leonids are weakly dependent on meteor mass, although the dust-ball theory assumes they should be mass independent.

  13. Isoperformance curves in applied psychology.

    PubMed

    Jones, M B; Kennedy, R S

    1996-03-01

    Isoperformance is a technique for reading information out of a data-analytic model, comparable to expected mean square or omega squared analyses. It results in a trade-off function (an isoperformance curve) among the determinants of performance. The technique was developed primarily to generate trade-off functions between personnel aptitude and time in training or on the job. However, the technique is general and can be applied in any trade-off situation. In part, the purpose of this paper is to recall the antecedents of isoperformance in psychophysics and to recount the origins and development of the isoperformance readout. Its main purpose, however, is to present several examples of isoperformance curves in applied psychology and to make the case for their usefulness.

  14. Infinite swapping in curved spaces

    NASA Astrophysics Data System (ADS)

    Curotto, E.; Mella, Massimo

    2014-01-01

    We develop an extension of the infinite swapping and partial infinite swapping techniques [N. Plattner, J. D. Doll, P. Dupuis, H. Wang, Y. Liu, and J. E. Gubernatis, J. Chem. Phys. 135, 134111 (2011)] to curved spaces. Furthermore, we test the performance of infinite swapping and partial infinite swapping in a series of flat spaces characterized by the same potential energy surface model. We develop a second order variational algorithm for general curved spaces without the extended Lagrangian formalism to include holonomic constraints. We test the new methods by carrying out NVT classical ensemble simulations on a set of multidimensional toroids mapped by stereographic projections and characterized by a potential energy surface built from a linear combination of decoupled double wells shaped purposely to create rare events over a range of temperatures.

  15. Optical conductivity of curved graphene.

    PubMed

    Chaves, A J; Frederico, T; Oliveira, O; de Paula, W; Santos, M C

    2014-05-01

    We compute the optical conductivity for an out-of-plane deformation in graphene using an approach based on solutions of the Dirac equation in curved space. Different examples of periodic deformations along one direction translates into an enhancement of the optical conductivity peaks in the region of the far- and mid-infrared frequencies for periodicities ∼100 nm. The width and position of the peaks can be changed by dialling the parameters of the deformation profiles. The enhancement of the optical conductivity is due to intraband transitions and the translational invariance breaking in the geometrically deformed background. Furthermore, we derive an analytical solution of the Dirac equation in a curved space for a general deformation along one spatial direction. For this class of geometries, it is shown that curvature induces an extra phase in the electron wave function, which can also be explored to produce interference devices of the Aharonov-Bohm type.

  16. Accelerating Around an Unbanked Curve

    NASA Astrophysics Data System (ADS)

    Mungan, Carl E.

    2006-02-01

    The December 2004 issue of TPT presented a problem concerning how a car should accelerate around an unbanked curve of constant radius r starting from rest if it is to avoid skidding. Interestingly enough, two solutions were proffered by readers.2 The purpose of this note is to compare and contrast the two approaches. Further experimental investigation of various turning strategies using a remote-controlled car and overhead video analysis could make for an interesting student project.

  17. Test Rig for Evaluating Active Turbine Blade Tip Clearance Control Concepts

    NASA Technical Reports Server (NTRS)

    Lattime, Scott B.; Steinetz, Bruce M.; Robbie, Malcolm G.

    2003-01-01

    Improved blade tip sealing in the high pressure compressor and high pressure turbine can provide dramatic improvements in specific fuel consumption, time-on-wing, compressor stall margin and engine efficiency as well as increased payload and mission range capabilities of both military and commercial gas turbine engines. The preliminary design of a mechanically actuated active clearance control (ACC) system for turbine blade tip clearance management is presented along with the design of a bench top test rig in which the system is to be evaluated. The ACC system utilizes mechanically actuated seal carrier segments and clearance measurement feedback to provide fast and precise active clearance control throughout engine operation. The purpose of this active clearance control system is to improve upon current case cooling methods. These systems have relatively slow response and do not use clearance measurement, thereby forcing cold build clearances to set the minimum clearances at extreme operating conditions (e.g., takeoff, re-burst) and not allowing cruise clearances to be minimized due to the possibility of throttle transients (e.g., step change in altitude). The active turbine blade tip clearance control system design presented herein will be evaluated to ensure that proper response and positional accuracy is achievable under simulated high-pressure turbine conditions. The test rig will simulate proper seal carrier pressure and temperature loading as well as the magnitudes and rates of blade tip clearance changes of an actual gas turbine engine. The results of these evaluations will be presented in future works.

  18. Effects of CdCl/sub 2/ on the maternal-to-fetal clearance of /sup 67/Cu and placental blood flow

    SciTech Connect

    Chertok, R.J.; Kullgren, B.; Burbank, D.

    1984-06-01

    Copper is an essential element while Cd is an extremely toxic heavy metal of questionable biological usefulness. Cadmium has been reported to interfere with the metabolism of Cu, be teratogenic, and decrease blood flow in the fetal placenta. Because of these reported biological interactions of Cd and Cu, this investigation was conducted to determine the effects of Cd on placental transport of /sup 67/Cu and placental blood flow in the guinea pig. All guinea pigs used were 60 +/- 1 days pregnant. A placental perfusion technique was used to measure the maternal-to-fetal clearance of /sup 67/Cu and /sup 3/H/sub 2/O across the placenta. The clearance of /sup 3/H/sub 2/O served as an indicator of placental blood flow on the maternal side of the circulation. The results indicated that an iv injection of 1 mg Cd/kg body weight resulted in an immediate increase in the clearance of /sup 67/Cu which declined over the next 8 min to an elevated level compared to the extrapolated best-fit curve of control values. This iv injection of CdCl/sub 2/ concomitantly reduced the maternal-to-fetal clearance of /sup 3/H/sub 2/O across the placenta. In conclusion, an acute exposure of the pregnant female to CdCl/sub 2/ results in an increased maternal-to-fetal clearance of /sup 67/Cu and a reduced placental blood flow that can alter the supply of nutrients to the developing embryo or fetus, and therefore modify normal development.

  19. Effects of CdCl/sub 2/ on the maternal-to-fetal clearance of /sup 67/Cu and placental blood flow

    SciTech Connect

    Chertok, R.J.; Kullgren, B.; Burbank, D.

    1984-05-01

    Copper is an essential element while Cd is an extremely toxic heavy metal of questionable biological usefulness. Cadmium has been reported to interfere with the metabolism of Cu, be teratogenic, and decrease blood flow in the fetal placenta. Because of these reported biological interactions of Cd and Cu, this investigation was conducted to determine the effects of Cd on placental transport of /sup 67/Cu and placental blood flow in the guinea pig. All guinea pigs used were 60 +/- 1 days pregnant. A placental perfusion technique was used to measure the maternal-to-fetal clearance of /sup 67/Cu and /sup 3/H/sub 2/O across the placenta. The clearance of /sup 3/H/sub 2/O served as an indicator of placental blood flow on the maternal side of the circulation. The results indicated that an iv injection of 1 mg Cd/kg body weight resulted in an immediate increase in the clearance of /sup 67/Cu which declined over the next 8 min to an elevated level compared to the extrapolated best-fit curve of control values. This iv injection of CdCl/sub 2/ concomitantly reduced the maternal-to-fetal clearance of /sup 3/H/sub 2/O across the placenta. In conclusion, an acute exposure of the pregnant female to CdCl/sub 2/ results in an increased maternal-to-fetal clearance /sup 67/Cu and a reduced placental blood flow that can alter the supply of nutrients to the developing embryo or fetus, and therefore modify normal development.

  20. A Matter of Millimeters: Defining the Processes for Critical Clearances on Curiosity

    NASA Technical Reports Server (NTRS)

    Florow, Brandon

    2013-01-01

    The Mars Science Laboratory (MSL) mission presents an immense packaging problem in that it takes a rover the size of a car with a sky crane landing system and packs it tightly into a spacecraft. This creates many areas of close and critical clearances. Critical Clearances are defined as hardware-to-hardware or hardware-to-envelope clearances which fall below a pre-established location dependent threshold and pose a risk of hardware to hardware contact during events such as launch, entry, landing, and operations. Close Clearances, on the other hand, are defined as any clearance value that is chosen to be tracked but is larger than the critical clearance threshold for its region. Close clearances may be tracked for various reasons including uncertainty in design, large expected dynamic motion, etc.

  1. Integrating the Clearance in NPP Residual Material Management

    SciTech Connect

    Garcia-Bermejo, R.; Lamela, B.

    2008-01-15

    Previous Experiences in decommissioning projects are being used to optimize the residual material management in NPP, metallic scrap usually. The approach is based in the availability of a materials Clearance MARSSIM-based methodology developed and licensed in Spain. A typical project includes the integration of segregation, decontamination, clearance, quality control and quality assurance activities. The design is based in the clearance methodology features translating them into standard operational procedures. In terms of ecological taxes and final disposal costs, significant amounts of money could be saved with this type of approaches. The last clearance project managed a total amount of 405 tons scrap metal and a similar amount of other residual materials occupying a volume of 1500 m{sup 3}. After less than a year of field works 251 tons were finally recycled in a non-licensed smelting facility. The balance was disposed as LILW. In the planning phase the estimated cost savings were 4.5 Meuro. However, today a VLLW option is available in European countries so, the estimated cost savings are reduced to 1.2 Meuro. In conclusion: the application of materials clearance in NPP decommissioning lessons learnt to the NPP residual material management is an interesting management option. This practice is currently going on in Spanish NPP and, in a preliminary view, is consistent with the new MARSAME Draft. An interesting parameter is the cost of 1 m3 of recyclable scrap. The above estimates are very project specific because in the segregation process other residual materials were involved. If the effect of this other materials is removed the estimated Unit Cost were in this project around 1700 euro/m{sup 3}, this figure is clearly below the above VLLW disposal cost of 2600 euro. In a future project it appears feasible to descend to 839 euro/m{sup 3} and if it became routine values and is used in big Decommissioning projects, around 600 euro/m{sup 3} or below possibly could

  2. Use of uptake intrinsic clearance from attached rat hepatocytes to predict hepatic clearance for poorly permeable compounds.

    PubMed

    Huang, Liyue; Chen, April; Roberts, John; Janosky, Brett; Be, Xuhai; Berry, Loren; Lin, Min-Hwa Jasmine

    2012-09-01

    We previously reported that the accuracy of clearance (CL) prediction could be differentiated by permeability. CL was drastically under-predicted by in vitro metabolic intrinsic clearance (CL(int)) for compounds with low permeability (<5 × 10(-6) cm/s). We determined apparent uptake CL(int) by measuring initial disappearance from medium using attached rat hepatocytes and metabolic CL(int) by measuring parent depletion in suspended rat hepatocytes (cells and medium). Uptake and metabolic CL(int) were comparable for highly permeable metabolic marker compounds. In contrast, uptake CL(int) was 3- to 40-fold higher than metabolic CL(int) for rosuvastatin, bosentan, and 15 proprietary compounds, which had low permeability, suggesting that uptake could be a rate-determining step in hepatic elimination for these poorly permeable compounds. The prediction of hepatic CL was improved significantly when using uptake CL(int) for the compounds with low permeability. The average fold error was 2.2 and 6, as opposed to >11 and >47 by metabolic CL(int), with and without applying a scaling factor of 4, respectively. Uptake CL(int) from attached hepatocytes can be used as an alternative approach to predict hepatic clearance and to understand the significance of hepatic uptake in elimination in an early drug discovery setting. PMID:22439758

  3. Use of uptake intrinsic clearance from attached rat hepatocytes to predict hepatic clearance for poorly permeable compounds.

    PubMed

    Huang, Liyue; Chen, April; Roberts, John; Janosky, Brett; Be, Xuhai; Berry, Loren; Lin, Min-Hwa Jasmine

    2012-09-01

    We previously reported that the accuracy of clearance (CL) prediction could be differentiated by permeability. CL was drastically under-predicted by in vitro metabolic intrinsic clearance (CL(int)) for compounds with low permeability (<5 × 10(-6) cm/s). We determined apparent uptake CL(int) by measuring initial disappearance from medium using attached rat hepatocytes and metabolic CL(int) by measuring parent depletion in suspended rat hepatocytes (cells and medium). Uptake and metabolic CL(int) were comparable for highly permeable metabolic marker compounds. In contrast, uptake CL(int) was 3- to 40-fold higher than metabolic CL(int) for rosuvastatin, bosentan, and 15 proprietary compounds, which had low permeability, suggesting that uptake could be a rate-determining step in hepatic elimination for these poorly permeable compounds. The prediction of hepatic CL was improved significantly when using uptake CL(int) for the compounds with low permeability. The average fold error was 2.2 and 6, as opposed to >11 and >47 by metabolic CL(int), with and without applying a scaling factor of 4, respectively. Uptake CL(int) from attached hepatocytes can be used as an alternative approach to predict hepatic clearance and to understand the significance of hepatic uptake in elimination in an early drug discovery setting.

  4. Lansoprazole increases testosterone metabolism and clearance in male Sprague-Dawley rats: implications for Leydig cell carcinogenesis.

    PubMed

    Coulson, Michelle; Gibson, G Gordon; Plant, Nick; Hammond, Tim; Graham, Mark

    2003-10-15

    Leydig cell tumours (LCTs) are frequently observed during rodent carcinogenicity studies, however, the significance of this effect to humans remains a matter of debate. Many chemicals that produce LCTs also induce hepatic cytochromes P450 (CYPs), but it is unknown whether these two phenomena are causally related. Our aim was to investigate the existence of a liver-testis axis wherein microsomal enzyme inducers enhance testosterone metabolic clearance, resulting in a drop in circulating hormone levels and a consequent hypertrophic response from the hypothalamic-pituitary-testis axis. Lansoprazole was selected as the model compound as it induces hepatic CYPs and produces LCTs in rats. Male Sprague-Dawley rats were dosed with lansoprazole (150 mg/kg/day) or vehicle for 14 days. Lansoprazole treatment produced effects on the liver consistent with an enhanced metabolic capacity, including significant increases in relative liver weights, total microsomal CYP content, individual CYP protein levels, and enhanced CYP-dependent testosterone metabolism in vitro. Following intravenous administration of [14C]testosterone, lansoprazole-treated rats exhibited a significantly smaller area under the curve and significantly higher plasma clearance. Significant reductions in plasma and testicular testosterone levels were observed, confirming the ability of this compound to perturb androgen homeostasis. No significant changes in plasma LH, FSH, or prolactin levels were detected under our experimental conditions. Lansoprazole treatment exerted no marked effects on testicular testosterone metabolism. In summary, lansoprazole treatment induced hepatic CYP-dependent testosterone metabolism in vitro and enhanced plasma clearance of radiolabelled testosterone in vivo. These effects may contribute to depletion of circulating testosterone levels and hence play a role in the mode of LCT induction in lansoprazole-treated rats.

  5. Compression of contour data through exploiting curve-to-curve dependence

    NASA Technical Reports Server (NTRS)

    Yalabik, N.; Cooper, D. B.

    1975-01-01

    An approach to exploiting curve-to-curve dependencies in order to achieve high data compression is presented. One of the approaches to date of along curve compression through use of cubic spline approximation is taken and extended by investigating the additional compressibility achievable through curve-to-curve structure exploitation. One of the models under investigation is reported on.

  6. NLINEAR - NONLINEAR CURVE FITTING PROGRAM

    NASA Technical Reports Server (NTRS)

    Everhart, J. L.

    1994-01-01

    A common method for fitting data is a least-squares fit. In the least-squares method, a user-specified fitting function is utilized in such a way as to minimize the sum of the squares of distances between the data points and the fitting curve. The Nonlinear Curve Fitting Program, NLINEAR, is an interactive curve fitting routine based on a description of the quadratic expansion of the chi-squared statistic. NLINEAR utilizes a nonlinear optimization algorithm that calculates the best statistically weighted values of the parameters of the fitting function and the chi-square that is to be minimized. The inputs to the program are the mathematical form of the fitting function and the initial values of the parameters to be estimated. This approach provides the user with statistical information such as goodness of fit and estimated values of parameters that produce the highest degree of correlation between the experimental data and the mathematical model. In the mathematical formulation of the algorithm, the Taylor expansion of chi-square is first introduced, and justification for retaining only the first term are presented. From the expansion, a set of n simultaneous linear equations are derived, which are solved by matrix algebra. To achieve convergence, the algorithm requires meaningful initial estimates for the parameters of the fitting function. NLINEAR is written in Fortran 77 for execution on a CDC Cyber 750 under NOS 2.3. It has a central memory requirement of 5K 60 bit words. Optionally, graphical output of the fitting function can be plotted. Tektronix PLOT-10 routines are required for graphics. NLINEAR was developed in 1987.

  7. Seeing effects on occultation curves.

    NASA Technical Reports Server (NTRS)

    Young, A. T.

    1971-01-01

    Evaluation of seeing effects on the light curve of a stellar occultation by the moon. Some theoretical studies of Fried (1966) and Hulett (1967) on the linear size of the downward-looking seeing disk are cited, showing that the seeing blur amounts to a few centimeters for a star in the zenith and that the linear blur must grow approximately as (sec z) to the 3/2 power. For most observations the seeing blur will not exceed 8 to 10 cm. The limitation on angular resolution imposed by this seeing effect is calculated.

  8. Curved microchannels and bacterial streamers

    NASA Astrophysics Data System (ADS)

    Rusconi, Roberto; Lecuyer, Sigolene; Guglielmini, Laura; Stone, Howard

    2010-03-01

    Bacterial biofilms are commonly identified as microbial communities attached to a surface and encased in a self-secreted extracellular matrix. Due to their increased resistance to antimicrobial agents, biofilms have an enormous impact on health and medicine (e.g., wound healing, implant-associated infections, disease transmission). On the other hand, they constitute a major component of the stream ecosystem by increasing transport of nutrients and retention of suspended particles. In this talk, we present an experimental study of bacterial biofilm development in a microfluidic device. In particular, we show the formation of filamentous structures, or streamers, in curved channels and how these suspended biofilms are linked to the underlying hydrodynamics.

  9. Clearance and synthesis rates of beta 2-microglobulin in patients undergoing hemodialysis and in normal subjects

    SciTech Connect

    Floege, J.; Bartsch, A.; Schulze, M.; Shaldon, S.; Koch, K.M.; Smeby, L.C. )

    1991-08-01

    Retention of {beta} 2-microglobulin in patients undergoing hemodialysis is associated with a {beta} 2-microglobulin-derived amyloidosis. Removal of {beta} 2-microglobulin by renal replacement therapy has been proposed for the prevention of this amyloidosis. Currently, however, data on the {beta} 2-microglobulin synthesis rate in patients undergoing hemodialysis are scarce, and consequently it remains speculative how much removal would be necessary to counterbalance synthesis. The plasma kinetics of iodine 131-labeled {beta} 2-microglobulin were therefore examined in 11 patients with anuria who were undergoing long-term hemodialysis. Five healthy persons served as controls. Kinetic modeling of the plasma curves showed that the data fitted a two-pool model (r2 greater than 0.96) consisting of a rapid 2 to 4 hour distribution phase followed by a less steep curve, described by the plasma (metabolic) clearance (Clp). Synthetic rates were calculated from Clp and the {beta} 2-microglobulin steady state plasma concentration (plus {beta} 2-microglobulin removal during hemodialysis in the case of high flux hemodialysis). The results showed a significantly higher Clp in normal controls as compared with patients undergoing hemodialysis (65.5 {plus minus} 12.8 ml/min (mean {plus minus} SD) versus 3.4 {plus minus} 0.7 ml/min). In contrast, the {beta} 2-microglobulin synthesis rate in the patient group (3.10 {plus minus} 0.79 mg/kg/day) was not significantly different from that of normal controls (2.40 {plus minus} 0.67 mg/kg/day), which was due to markedly elevated {beta} 2-microglobulin plasma concentrations in the patients (37.6 {plus minus} 14.1 mg/L vs 1.92 {plus minus} 0.27 mg/L). These findings suggest that the presence of end-stage renal disease does not have a significant impact on the beta 2-microglobulin generation rate.

  10. Distribution of sucrose around the mouth and its clearance after a sucrose mouthrinse or consumption of three different foods.

    PubMed

    Macpherson, L M; Dawes, C

    1994-01-01

    The distribution of sucrose in whole saliva and in saliva from seven different regions of the mouth was determined in 10 subjects over the 10-min period following the chewing of a doughnut, sucking on a mint candy, the drinking of orange juice, or use of a 10% sucrose mouthrinse. With all products, the sucrose was distributed non-uniformly, with particularly low concentrations on the lingual surfaces of the lower incisors and the facial surfaces of the upper molars. Clearance was also most rapid from these sites. Since the depth and duration of a Stephan curve in dental plaque is influenced by the sugar concentration to which the plaque is exposed, the results, together with previous results on salivary film velocity in different regions of the mouth, help to provide an explanation for the site-specificity of smooth-surface caries and of supragingival calculus deposition. PMID:8033187

  11. Miniature curved artificial compound eyes

    PubMed Central

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L’Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A.; Franceschini, Nicolas

    2013-01-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories. PMID:23690574

  12. Curved-stem Hip Resurfacing

    PubMed Central

    2008-01-01

    Hip resurfacing is an attractive concept because it preserves rather than removes the femoral head and neck. Most early designs had high failure rates, but one unique design had a femoral stem. Because that particular device appeared to have better implant survival, this study assessed the clinical outcome and long-term survivorship of a hip resurfacing prosthesis. Four hundred forty-five patients (561 hips) were retrospectively reviewed after a minimum of 20 years’ followup or until death; 23 additional patients were lost to followup. Patients received a metal femoral prosthesis with a small curved stem. Three types of acetabular reconstructions were used: (1) cemented polyurethane; (2) metal-on-metal; and (3) polyethylene secured with cement or used as the liner of a two-piece porous-coated implant. Long-term results were favorable with the metal-on-metal combination only. The mean overall Harris hip score was 92 at 2 years of followup. None of the 121 patients (133 hips) who received metal-on-metal articulation experienced failure. The failure rate with polyurethane was 100%, and the failure rate with cemented polyethylene was 41%. Hip resurfacing with a curved-stem femoral component had a durable clinical outcome when a metal-on-metal articulation was used. Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence. PMID:18338217

  13. Miniature curved artificial compound eyes.

    PubMed

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L'Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A; Franceschini, Nicolas

    2013-06-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories. PMID:23690574

  14. Miniature curved artificial compound eyes.

    PubMed

    Floreano, Dario; Pericet-Camara, Ramon; Viollet, Stéphane; Ruffier, Franck; Brückner, Andreas; Leitel, Robert; Buss, Wolfgang; Menouni, Mohsine; Expert, Fabien; Juston, Raphaël; Dobrzynski, Michal Karol; L'Eplattenier, Geraud; Recktenwald, Fabian; Mallot, Hanspeter A; Franceschini, Nicolas

    2013-06-01

    In most animal species, vision is mediated by compound eyes, which offer lower resolution than vertebrate single-lens eyes, but significantly larger fields of view with negligible distortion and spherical aberration, as well as high temporal resolution in a tiny package. Compound eyes are ideally suited for fast panoramic motion perception. Engineering a miniature artificial compound eye is challenging because it requires accurate alignment of photoreceptive and optical components on a curved surface. Here, we describe a unique design method for biomimetic compound eyes featuring a panoramic, undistorted field of view in a very thin package. The design consists of three planar layers of separately produced arrays, namely, a microlens array, a neuromorphic photodetector array, and a flexible printed circuit board that are stacked, cut, and curved to produce a mechanically flexible imager. Following this method, we have prototyped and characterized an artificial compound eye bearing a hemispherical field of view with embedded and programmable low-power signal processing, high temporal resolution, and local adaptation to illumination. The prototyped artificial compound eye possesses several characteristics similar to the eye of the fruit fly Drosophila and other arthropod species. This design method opens up additional vistas for a broad range of applications in which wide field motion detection is at a premium, such as collision-free navigation of terrestrial and aerospace vehicles, and for the experimental testing of insect vision theories.

  15. An integrated approach to model hepatic drug clearance.

    PubMed

    Liu, Lichuan; Pang, K Sandy

    2006-11-01

    It has been well accepted that hepatic drug extraction depends on the blood flow, vascular binding, transmembrane barriers, transporters, enzymes and cosubstrate and their zonal heterogeneity. Models of hepatic drug clearances have been appraised with respect to their utility in predicting drug removal by the liver. Among these models, the "well-stirred" model is the simplest since it assumes venous equilibration, with drug emerging from the outflow being in equilibrium with drug within the liver, and the concentration is the same throughout. The "parallel tube" and dispersion models, and distributed model of Goresky and co-workers have been used to account for the observed sinusoidal concentration gradient from the inlet and outlet. Departure from these models exists to include heterogeneity in flow, enzymes, and transporters. This article utilized the physiologically based pharmacokinetic (PBPK) liver model and its extension that include heterogeneity in enzymes and transporters to illustrate how in vitro uptake and metabolic data from zonal hepatocytes on transport and enzymes may be used to predict the kinetics of removal in the intact liver; binding data were also necessary. In doing so, an integrative platform was provided to examine determinants of hepatic drug clearance. We used enalapril and digoxin as examples, and described a simple liver PBPK model that included transmembrane transport and metabolism occurring behind the membrane, and a zonal model in which the PBPK model was expanded three sets of sub-compartments that are arranged sequentially to represent zones 1, 2, and 3 along the flow path. The latter model readily accommodated the heterogeneous distribution of hepatic enzymes and transporters. Transport and metabolic data, piecewise information that served as initial estimates, allowed for the unknown efflux and other intrinsic clearances to be estimated. The simple or zonal PBPK model provides predictive views on the hepatic removal of drugs and

  16. Analysis and design of a uniform-clearance, pumping-ring rod seal for the Stirling engine

    NASA Technical Reports Server (NTRS)

    Etsion, I.

    1980-01-01

    A uniform clearance pumping ring, as opposed to the conventional taper clearance one, is described. The uniform clearance concept eliminates complex elastohydrodynamic problems and enables a simple analytical treatment to be made. An analytical expression is derived for the pumping rate showing the effect of various design parameters on the pumping ring's performance. An optimum clearance is found by which the pumping rate is maximized and a numerical example is presented to demonstrate the potential of the uniform clearance design.

  17. Autophagic clearance of bacterial pathogens: molecular recognition of intracellular microorganisms

    PubMed Central

    Mansilla Pareja, Maria Eugenia; Colombo, Maria I.

    2013-01-01

    Autophagy is involved in several physiological and pathological processes. One of the key roles of the autophagic pathway is to participate in the first line of defense against the invasion of pathogens, as part of the innate immune response. Targeting of intracellular bacteria by the autophagic machinery, either in the cytoplasm or within vacuolar compartments, helps to control bacterial proliferation in the host cell, controlling also the spreading of the infection. In this review we will describe the means used by diverse bacterial pathogens to survive intracellularly and how they are recognized by the autophagic molecular machinery, as well as the mechanisms used to avoid autophagic clearance. PMID:24137567

  18. Possible risks to human lungs from magnetometric dust clearance experiments

    NASA Astrophysics Data System (ADS)

    Sterling, T. D.

    1981-03-01

    Cohen, Arai and Brain did a magnetization study on smokers and nonsmokers from which they conclude that the dust clearance ability of the cigarette smoker's lungs is markedly impaired. Their conclusion may be incorrect because they overlooked that during the magnetization phase of their experiment, iron oxide clusters were preferentially formed in smoker's bronchi because of their high mucus content and consequent low resistance to redistribution of particles. Prudence dictates avoidance of the Cohen, Arai, Brain type study until health hazards related to this work are investigated.

  19. The pharmacologic approach to airway clearance: mucoactive agents.

    PubMed

    Rubin, Bruce K

    2006-01-01

    The term "mucoactive agent" refers to any medication used to improve the clearance of airway secretions. It is not synonymous with the word "mucolytic" as this strictly means a drug that decreases the viscosity of secretions. In many cases, decreased viscosity will adversely affect cough transport. For this reason many of the older mucolytic agents such as acetylcysteine are not effective for the therapy of lung disease and their use is not recommended. I review here the many classes of mucoactive agents and identify a number of medications with great promise for the treatment of chronic airway disease. PMID:16798570

  20. What is the best airway clearance technique in cystic fibrosis?

    PubMed

    Main, Eleanor

    2013-05-01

    The global development of airway clearance techniques (ACTs) for cystic fibrosis (CF) and corresponding research spans over four decades. Five Cochrane reviews synthesising the evidence from a plethora of early short and medium term studies have not uncovered any superior method. Four recent long term RCT studies exposed fundamental shortcomings in the standard RCT trial design and the insensitivity of FEV1 in physiotherapy studies. Strong patient preference, lack of blinding and the requirement for effortful and demanding participation over long intervals will continue to derail efforts to find the best ACT for CF, unless they are addressed in future clinical trials. PMID:23541002

  1. Rab7 induces clearance of α-synuclein aggregates.

    PubMed

    Dinter, Elisabeth; Saridaki, Theodora; Nippold, Markus; Plum, Sarah; Diederichs, Leonie; Komnig, Daniel; Fensky, Luisa; May, Caroline; Marcus, Katrin; Voigt, Aaron; Schulz, Jörg B; Falkenburger, Björn H

    2016-09-01

    Parkinson's disease can be caused by mutations in the α-synuclein gene and is characterized by aggregates of α-synuclein protein. Aggregates are degraded by the autophago-lysosomal pathway. Since Rab7 has been shown to regulate trafficking of late endosomes and autophagosomes, we hypothesized that over-expressing Rab7 might be beneficial in Parkinson's disease. To test this hypothesis, we expressed the pathogenic A53T mutant of α-synuclein in HEK293 cells and Drosophila melanogaster. In HEK293 cells, EGFP-Rab7-decorated vesicles contain α-synuclein. Rab7 over-expression reduced the percentage of cells with α-synuclein particles and the amount of α-synuclein protein. Time-lapse microscopy confirmed that particles frequently disappeared with Rab7 over-expression. Clearance of α-synuclein is explained by the increased occurrence of acidified α-synuclein vesicles with Rab7 over-expression, presumably representing autolysosomes. Rab7 over-expression reduced apoptosis and the percentage of dead cells in trypan blue staining. In the fly model, Rab7 rescued the locomotor deficit induced by neuronal expression of A53T-α-synuclein. These beneficial effects were not produced by Rab7 missense mutations causing Charcot Marie Tooth neuropathy, or by the related GTPases Rab5, Rab9, or Rab23. Using mass spectrometry, we identified Rab7 in neuromelanin granules purified from human substantia nigra, indicating that Rab7 might be involved in the biogenesis of these possibly protective, autophagosome-like organelles in dopaminergic neurons. Taken together, Rab7 increased the clearance of α-synuclein aggregates, reduced cell death, and rescued the phenotype in a fly model of Parkinson's disease. These findings indicate that Rab7 is rate-limiting for aggregate clearance, and that Rab7 activation may offer a therapeutic strategy for Parkinson's disease. Cells over-expressing aggregation-prone A53T alpha-synuclein develop cytoplasmic aggregates mimicking changes observed in

  2. Autophagic clearance of bacterial pathogens: molecular recognition of intracellular microorganisms.

    PubMed

    Pareja, Maria Eugenia Mansilla; Colombo, Maria I

    2013-01-01

    Autophagy is involved in several physiological and pathological processes. One of the key roles of the autophagic pathway is to participate in the first line of defense against the invasion of pathogens, as part of the innate immune response. Targeting of intracellular bacteria by the autophagic machinery, either in the cytoplasm or within vacuolar compartments, helps to control bacterial proliferation in the host cell, controlling also the spreading of the infection. In this review we will describe the means used by diverse bacterial pathogens to survive intracellularly and how they are recognized by the autophagic molecular machinery, as well as the mechanisms used to avoid autophagic clearance.

  3. The general efficiency curve for air propellers

    NASA Technical Reports Server (NTRS)

    Diehl, Walter S

    1924-01-01

    This report presents a formula which may be used to obtain a "general efficiency curve" in addition to the well-known maximum efficiency curve. These two curves, when modified somewhat by experimental data, enable performance calculations to be made without detailed knowledge of the propeller. The curves may also be used to estimate the improvement in efficiency due to reduction gearing, or to judge the performance of a new propeller design.

  4. Clearance of Tc-99m DTPA in hemodialysis and peritoneal dialysis: concise communication

    SciTech Connect

    Wainer, E.; Boner, G.; Lubin, E.; Rosenfeld, J.B.

    1981-09-01

    The clearance of Tc-99m DTPA was studied in 14 patients undergoing hemodialysis (HD) or peritoneal dialysis (PD). Mean Tc-99m DTPA clearance during HD was 37.8% +/- 10.1 of creatinine clearance. Mean Tc-99m DTPA clearance in PD was 65.1% +/- 10.3 of creatinine clearance. Tc-99m DTPA, with a larger molecular weight than that of creatinine, is cleared relatively better during PD than during HD. Thus Tc-99m DTPA may be used in the assessment of the effectiveness of different dialytic treatments for substances of similar molecular weight. In addition, our study shows that clearance of DTPA both in HD and PD is sufficiently high to allow the removal of this chelating agent in patients with renal failure.

  5. Experimental study of tip clearance losses and noise in axial turbomachines and their reduction

    SciTech Connect

    Kameier, F.; Neise, W.

    1997-07-01

    An experimental study is described to investigate the negative effects of the tip clearance gap on the aerodynamic and acoustic performance of axial turbomachines. In addition to the increased broadband levels reported in the literature when the tip clearance is enlarged, significant level increases were observed within narrow frequency bands below the blade passing frequency. Measurements of the pressure and velocity fluctuations in the vicinity of the blade tips reveal that the tip clearance noise is associated with a rotating flow instability at the blade tip, which in turn is only present under reversed flow conditions in the tip clearance gap. A turbulence generator inserted into the tip clearance gap is found to be effective in eliminating the tip clearance noise and in improving the aerodynamic performance.

  6. Large Deformation Diffeomorphic Metric Curve Mapping

    PubMed Central

    Glaunès, Joan; Miller, Michael I.; Younes, Laurent

    2010-01-01

    We present a matching criterion for curves and integrate it into the large deformation diffeomorphic metric mapping (LDDMM) scheme for computing an optimal transformation between two curves embedded in Euclidean space ℝd. Curves are first represented as vector-valued measures, which incorporate both location and the first order geometric structure of the curves. Then, a Hilbert space structure is imposed on the measures to build the norm for quantifying the closeness between two curves. We describe a discretized version of this, in which discrete sequences of points along the curve are represented by vector-valued functionals. This gives a convenient and practical way to define a matching functional for curves. We derive and implement the curve matching in the large deformation framework and demonstrate mapping results of curves in ℝ2 and ℝ3. Behaviors of the curve mapping are discussed using 2D curves. The applications to shape classification is shown and experiments with 3D curves extracted from brain cortical surfaces are presented. PMID:20419045

  7. Bacterial streamers in curved microchannels

    NASA Astrophysics Data System (ADS)

    Rusconi, Roberto; Lecuyer, Sigolene; Guglielmini, Laura; Stone, Howard

    2009-11-01

    Biofilms, generally identified as microbial communities embedded in a self-produced matrix of extracellular polymeric substances, are involved in a wide variety of health-related problems ranging from implant-associated infections to disease transmissions and dental plaque. The usual picture of these bacterial films is that they grow and develop on surfaces. However, suspended biofilm structures, or streamers, have been found in natural environments (e.g., rivers, acid mines, hydrothermal hot springs) and are always suggested to stem from a turbulent flow. We report the formation of bacterial streamers in curved microfluidic channels. By using confocal laser microscopy we are able to directly image and characterize the spatial and temporal evolution of these filamentous structures. Such streamers, which always connect the inner corners of opposite sides of the channel, are always located in the middle plane. Numerical simulations of the flow provide evidences for an underlying hydrodynamic mechanism behind the formation of the streamers.

  8. Automation for "Direct-to" Clearances in Air-Traffic Control

    NASA Technical Reports Server (NTRS)

    Erzberger, Heinz; McNally, David

    2006-01-01

    A method of automation, and a system of computer hardware and software to implement the method, have been invented to assist en-route air-traffic controllers in the issuance of clearances to fly directly to specified waypoints or navigation fixes along straight paths that deviate from previously filed flight plans. Such clearances, called "direct-to" clearances, have been in use since before the invention of this method and system.

  9. The screening value of the amylase-creatinine clearance ratio in acute pancreatitis.

    PubMed

    Van Hee, R; Hubens, A

    1979-01-01

    The screening value of the amylase creatinine clearance ratio in acute pancreatitis is studied. A series of 28 patients with pancreatic disease is compared with 80 controls and 82 patients with other intra-abdominal disease. The greatest specificity of the amylase creatinine clearance ratio value is reached at the 3.5 level. The amylase creatinine clearance ratio value proves to be of interest, not only in the diagnosis of acute pancreatitis but also in differentiating mild and heavy forms of pancreatitis.

  10. Participation of the hypophyseal-adrenal cortex system in thrombin clearance during immobilization stress

    NASA Technical Reports Server (NTRS)

    Kudryashov, B. A.; Uljanov, A. M.; Shapiro, F. B.; Bazazyan, G. G.

    1981-01-01

    Thrombin marked with I-131 resulted in a considerable increase of the thrombined clearance rate in healthy male rats during stress caused by an immobilization lasting 30 minutes, and in an increase of thrombin clearance occurred by a combination of immobilization and administration of adrenocorticotropin (ACTH). Contrary to ACTH, the thrombin clearance is not stimulated in healthy animals by hydrocortisone. The results of the examination are presented.

  11. Test Rig for Active Turbine Blade Tip Clearance Control Concepts: An Update

    NASA Technical Reports Server (NTRS)

    Taylor, Shawn; Steinetz, Bruce; Oswald, Jay; DeCastro, Jonathan; Melcher, Kevin

    2006-01-01

    The objective is to develop and demonstrate a fast-acting active clearance control system to improve turbine engine performance, reduce emissions, and increase service life. System studies have shown the benefits of reducing blade tip clearances in modern turbine engines. Minimizing blade tip clearances throughout the engine will contribute materially to meeting NASA's Ultra-Efficient Engine Technology (UEET) turbine engine project goals. NASA GRC is examining two candidate approaches including rub-avoidance and regeneration which are explained in subsequent slides.

  12. AKLSQF - LEAST SQUARES CURVE FITTING

    NASA Technical Reports Server (NTRS)

    Kantak, A. V.

    1994-01-01

    The Least Squares Curve Fitting program, AKLSQF, computes the polynomial which will least square fit uniformly spaced data easily and efficiently. The program allows the user to specify the tolerable least squares error in the fitting or allows the user to specify the polynomial degree. In both cases AKLSQF returns the polynomial and the actual least squares fit error incurred in the operation. The data may be supplied to the routine either by direct keyboard entry or via a file. AKLSQF produces the least squares polynomial in two steps. First, the data points are least squares fitted using the orthogonal factorial polynomials. The result is then reduced to a regular polynomial using Sterling numbers of the first kind. If an error tolerance is specified, the program starts with a polynomial of degree 1 and computes the least squares fit error. The degree of the polynomial used for fitting is then increased successively until the error criterion specified by the user is met. At every step the polynomial as well as the least squares fitting error is printed to the screen. In general, the program can produce a curve fitting up to a 100 degree polynomial. All computations in the program are carried out under Double Precision format for real numbers and under long integer format for integers to provide the maximum accuracy possible. AKLSQF was written for an IBM PC X/AT or compatible using Microsoft's Quick Basic compiler. It has been implemented under DOS 3.2.1 using 23K of RAM. AKLSQF was developed in 1989.

  13. Caloric curve of star clusters.

    PubMed

    Casetti, Lapo; Nardini, Cesare

    2012-06-01

    Self-gravitating systems, such as globular clusters or elliptical galaxies, are the prototypes of many-body systems with long-range interactions, and should be the natural arena in which to test theoretical predictions on the statistical behavior of long-range-interacting systems. Systems of classical self-gravitating particles can be studied with the standard tools of equilibrium statistical mechanics, provided the potential is regularized at small length scales and the system is confined in a box. The confinement condition looks rather unphysical in general, so that it is natural to ask whether what we learn with these studies is relevant to real self-gravitating systems. In order to provide an answer to this question, we consider a basic, simple, yet effective model of globular clusters: the King model. This model describes a self-consistently confined system, without the need of any external box, but the stationary state is a nonthermal one. In particular, we consider the King model with a short-distance cutoff on the interactions, and we discuss how such a cutoff affects the caloric curve, i.e., the relation between temperature and energy. We find that the cutoff stabilizes a low-energy phase, which is absent in the King model without cutoff; the caloric curve of the model with cutoff turns out to be very similar to that of previously studied confined and regularized models, but for the absence of a high-energy gaslike phase. We briefly discuss the possible phenomenological as well as theoretical implications of these results. PMID:23005049

  14. Caloric curve of star clusters.

    PubMed

    Casetti, Lapo; Nardini, Cesare

    2012-06-01

    Self-gravitating systems, such as globular clusters or elliptical galaxies, are the prototypes of many-body systems with long-range interactions, and should be the natural arena in which to test theoretical predictions on the statistical behavior of long-range-interacting systems. Systems of classical self-gravitating particles can be studied with the standard tools of equilibrium statistical mechanics, provided the potential is regularized at small length scales and the system is confined in a box. The confinement condition looks rather unphysical in general, so that it is natural to ask whether what we learn with these studies is relevant to real self-gravitating systems. In order to provide an answer to this question, we consider a basic, simple, yet effective model of globular clusters: the King model. This model describes a self-consistently confined system, without the need of any external box, but the stationary state is a nonthermal one. In particular, we consider the King model with a short-distance cutoff on the interactions, and we discuss how such a cutoff affects the caloric curve, i.e., the relation between temperature and energy. We find that the cutoff stabilizes a low-energy phase, which is absent in the King model without cutoff; the caloric curve of the model with cutoff turns out to be very similar to that of previously studied confined and regularized models, but for the absence of a high-energy gaslike phase. We briefly discuss the possible phenomenological as well as theoretical implications of these results.

  15. A porphyrin-PEG polymer with rapid renal clearance.

    PubMed

    Huang, Haoyuan; Hernandez, Reinier; Geng, Jumin; Sun, Haotian; Song, Wentao; Chen, Feng; Graves, Stephen A; Nickles, Robert J; Cheng, Chong; Cai, Weibo; Lovell, Jonathan F

    2016-01-01

    Tetracarboxylic porphyrins and polyethylene glycol (PEG) diamines were crosslinked in conditions that gave rise to a water-soluble porphyrin polyamide. Using PEG linkers 2 kDa or larger prevented fluorescence self-quenching. This networked porphyrin mesh was retained during dialysis with membranes with a 100 kDa pore size, yet passed through the membrane when centrifugal filtration was applied. Following intravenous administration, the porphyrin mesh, but not the free porphyrin, was rapidly cleared via renal excretion. The process could be monitored by fluorescence analysis of collected urine, with minimal background due to the large Stokes shift of the porphyrin (230 nm separating excitation and emission peaks). In a rhabdomyolysis mouse model of renal failure, porphyrin mesh urinary clearance was significantly impaired. This led to slower accumulation in the bladder, which could be visualized non-invasively via fluorescence imaging. Without further modification, the porphyrin mesh was chelated with (64)Cu for dynamic whole body positron emission tomography imaging of renal clearance. Together, these data show that small porphyrin-PEG polymers can serve as effective multimodal markers of renal function. PMID:26517562

  16. Clearance Pathways and Tumor Targeting of Imaging Nanoparticles

    PubMed Central

    Yu, Mengxiao; Zheng, Jie

    2016-01-01

    A basic understanding of how imaging nanoparticles are removed from the normal organs/tissues but retained in the tumors is important for their future clinical applications in early cancer diagnosis and therapy. In this review, we discuss current understandings of clearance pathways and tumor targeting of small-molecule- and inorganic-nanoparticle-based imaging probes with an emphasis on molecular nanoprobes, a class of inorganic nanoprobes that can escape reticuloendothelial system (RES) uptake and be rapidly eliminated from the normal tissues/organs via kidneys but can still passively target the tumor with high efficiency through the enhanced permeability permeability and retention (EPR) effect. The impact of nanoparticle design (size, shape, and surface chemistry) on their excretion, pharmacokinetics, and passive tumor targeting were quantitatively discussed. Synergetic integration of effective renal clearance and EPR effect offers a promising pathway to design low-toxicity and high-contrast-enhancement imaging nanoparticles that could meet with the clinical translational requirements of regulatory agencies. PMID:26149184

  17. Reduction in slow intercompartmental clearance of urea during dialysis

    SciTech Connect

    Bowsher, D.J.; Krejcie, T.C.; Avram, M.J.; Chow, M.J.; Del Greco, F.; Atkinson, A.J. Jr.

    1985-04-01

    The kinetics of urea and inulin were analyzed in five anesthetized dogs during sequential 2-hour periods before, during, and after hemodialysis. The distribution of both compounds after simultaneous intravenous injection was characterized by three-compartment models, and the total volumes of urea (0.66 +/- 0.05 L/kg) and inulin (0.19 +/- 0.01 L/kg) distribution were similar to expected values for total body water and extravascular space, respectively. Intercompartmental clearances calculated before dialysis were used to estimate blood flows to the fast and slow equilibrating compartments. In agreement with previous results, the sum of these flows was similar to cardiac output, averaging 101% of cardiac output measured before dialysis (range 72% to 135%). Dialysis was accompanied by reductions in the slow intercompartmental clearances of urea (81%) and inulin (47%), which reflected a 90% attenuation in blood flow supplying the slow equilibrating compartments. This was estimated to result in a 10% average reduction in the efficiency with which urea was removed by dialysis (range 2.0% to 16.4%). Mean arterial pressure fell by less than 5% during dialysis, but total peripheral resistance increased by 47% and cardiac output fell by 35%. In the postdialysis period, total peripheral resistance and cardiac output returned toward predialysis values, but blood flow to the slow equilibrating peripheral compartment was still reduced by 80%. These changes parallel activation of the renin-angiotensin system, but further studies are required to establish causality.

  18. Activity-Dependent Plasticity of Astroglial Potassium and Glutamate Clearance

    PubMed Central

    Cheung, Giselle; Sibille, Jérémie; Zapata, Jonathan; Rouach, Nathalie

    2015-01-01

    Recent evidence has shown that astrocytes play essential roles in synaptic transmission and plasticity. Nevertheless, how neuronal activity alters astroglial functional properties and whether such properties also display specific forms of plasticity still remain elusive. Here, we review research findings supporting this aspect of astrocytes, focusing on their roles in the clearance of extracellular potassium and glutamate, two neuroactive substances promptly released during excitatory synaptic transmission. Their subsequent removal, which is primarily carried out by glial potassium channels and glutamate transporters, is essential for proper functioning of the brain. Similar to neurons, different forms of short- and long-term plasticity in astroglial uptake have been reported. In addition, we also present novel findings showing robust potentiation of astrocytic inward currents in response to repetitive stimulations at mild frequencies, as low as 0.75 Hz, in acute hippocampal slices. Interestingly, neurotransmission was hardly affected at this frequency range, suggesting that astrocytes may be more sensitive to low frequency stimulation and may exhibit stronger plasticity than neurons to prevent hyperexcitability. Taken together, these important findings strongly indicate that astrocytes display both short- and long-term plasticity in their clearance of excess neuroactive substances from the extracellular space, thereby regulating neuronal activity and brain homeostasis. PMID:26346563

  19. Sulforaphane enhances progerin clearance in Hutchinson-Gilford progeria fibroblasts.

    PubMed

    Gabriel, Diana; Roedl, Daniela; Gordon, Leslie B; Djabali, Karima

    2015-02-01

    Hutchinson-Gilford progeria syndrome (HGPS, OMIM 176670) is a rare multisystem childhood premature aging disorder linked to mutations in the LMNA gene. The most common HGPS mutation is found at position G608G within exon 11 of the LMNA gene. This mutation results in the deletion of 50 amino acids at the carboxyl-terminal tail of prelamin A, and the truncated protein is called progerin. Progerin only undergoes a subset of the normal post-translational modifications and remains permanently farnesylated. Several attempts to rescue the normal cellular phenotype with farnesyltransferase inhibitors (FTIs) and other compounds have resulted in partial cellular recovery. Using proteomics, we report here that progerin induces changes in the composition of the HGPS nuclear proteome, including alterations to several components of the protein degradation pathways. Consequently, proteasome activity and autophagy are impaired in HGPS cells. To restore protein clearance in HGPS cells, we treated HGPS cultures with sulforaphane (SFN), an antioxidant derived from cruciferous vegetables. We determined that SFN stimulates proteasome activity and autophagy in normal and HGPS fibroblast cultures. Specifically, SFN enhances progerin clearance by autophagy and reverses the phenotypic changes that are the hallmarks of HGPS. Therefore, SFN is a promising therapeutic avenue for children with HGPS.

  20. Bacterial clearance in the intact and regenerating liver

    SciTech Connect

    Gross, K.; Katz, S.; Dunn, S.P.; Cikrit, D.; Rosenthal, R.; Grosfeld, J.L.

    1985-08-01

    The Kupffer cells in the liver play an important role in reticuloendothelial system (RES) function by clearing particulate matter and bacteria from the blood stream. While hepatocyte regeneration and function have been extensively studied following partial hepatectomy, little information is available concerning RES function in the regenerating liver. This study investigates hepatic RES function by evaluating bacterial clearance (live E. coli) in the intact and regenerating liver. Thirty-four young male Sprague Dawley rats were studied. Twenty-two animals underwent a standard 70% partial hepatectomy using ligature technique and 12 had a sham operation. Both groups of rats received 10(9) organism of TVS labeled E coli, intravenously at 24 hours, 72 hours, 2 1/2 weeks, and 6 weeks postoperatively. Rats were killed 10 minutes following injection and liver, lung, spleen, and kidney harvested, fixed, and radioactivity was determined using a scintillation spectrometer interfaced with a micro-computer counting the TVS radiolabel. The total organ count of trapped bacteria in liver in partially hepatectomized rats was lower than intact controls at 24 hours, but was similar at 72 hours, 2 1/2 weeks, and 6 weeks. Partial hepatectomy increased the amount of bacterial trapping in the lung at 24 hours and 72 hours and returned to normal at 2 1/2 weeks and 6 weeks. Splenic activity was increased following hepatectomy at 2 1/2 weeks. Renal clearance was increased at 72 hours and 2 1/2 weeks.