Science.gov

Sample records for 184-inch berkeley cyclotron

  1. Environmental assessment for the recycling of slightly activated copper coil windings from the 184-Inch Cyclotron at Lawrence Berkeley Laboratory, Berkeley, California

    SciTech Connect

    Not Available

    1993-08-02

    The proposed action is to recycle slightly activated copper that is currently stored in a warehouse leased by Lawrence Berkeley Laboratory (LBL) to a scrap metal dealer. Subsequent reutilization of the copper would be unrestricted. This document addresses the potential environmental effects of recycling and reutilizing the activated copper. In addition, the potential environmental effects of possible future uses by the dealer are addressed. Direct environmental effects from the proposed action are assessed, such as air emissions from reprocessing the activated copper, as well as indirect beneficial effects, such as averting air emissions that would result from mining and smelting an equivalent quantity of copper ore. Evaluation of the human health impacts of the proposed action focuses on the pertinent issues of radiological doses and protection of workers and the public. Five alternatives to the proposed action are considered, and their associated potential impacts are addressed. The no-action alternative is the continued storage of the activated copper at the LBL warehouse. Two recycling alternatives are considered: recycling the activated copper at the Scientific Ecology Group (SEG) facility for re-use at a DOE facility and selling or giving the activated copper to a foreign government. In addition, two disposal alternatives evaluate the impacts attributable to disposing of the activated copper either at a local sanitary landfill or at the Hanford Low-Level Waste Burial Site. The proposed project and alternatives include no new construction or development of new industry.

  2. The Berkeley accelerator space effects facility (BASE) - A newmission for the 88-inch cyclotron at LBNL

    SciTech Connect

    McMahan, M.A.

    2005-09-06

    In FY04, the 88-Inch Cyclotron began a new operating mode that supports a local research program in nuclear science, R&D in accelerator technology and a test facility for the National Security Space (NSS) community (the U.S. Air Force and NRO). The NSS community (and others on a cost recovery basis) can take advantage of both the light- and heavy-ion capabilities of the Cyclotron to simulate the space radiation environment. A significant portion of this work involves the testing of microcircuits for single event effects. The experimental areas within the building that are used for the radiation effects testing are now called the Berkeley Accelerator and Space Effects (BASE) facility. Improvements to the facility to provide increased reliability, quality assurance and new capabilities are underway and will be discussed. These include a 16 AMeV ''cocktail'' of beams for heavy ion testing, a neutron beam, more robust dosimetry, and other upgrades.

  3. Use of a krypton isotope for rapid ion changeover at the Lawrence Berkeley Laboratory 88-inch cyclotron

    NASA Technical Reports Server (NTRS)

    Soli, George A.; Nichols, Donald K.

    1989-01-01

    An isotope of krypton, Kr86, has been combined with a mix of Ar, Ne, and N ions at the electron cyclotron resonance (ECR) source, at the Lawrence Berkeley Laboratory cyclotron, to provide rapid ion changeover in Single Event Phenomena (SEP) testing. The new technique has been proved out successfully by a recent Jet Propulsion Laboratory (JPL) test in which it was found that there was no measurable contamination from other isotopes.

  4. Berkeley College, Yale University.

    ERIC Educational Resources Information Center

    Russell, James S.

    2000-01-01

    Examines the controversial architectural technique of combining contemporary features with traditional designs at Yale University's Berkeley College, and discusses whether there is a place for this type of juxtaposition in architectural design. Photos and diagrams are included. (GR)

  5. Berkeley CMB Experiments

    NASA Astrophysics Data System (ADS)

    Richards, P. L.

    This paper describes the status of four CMB cosmology experiments which are currently being developed by the Berkeley group. These include the APEXSZ and South Pole Telescope searches for clusters of galaxies using the Sunyaev-Zeldovich effect and the Polar Bear and EBEX CMB polarization anisotropy experiments. These experiments exploit new detector technologies with Superconducting TES bolometers and frequency domain output multiplexing, which has been developed at Berkeley.

  6. Graduate Education at Berkeley.

    ERIC Educational Resources Information Center

    Duster, Troy

    1987-01-01

    Explains the history and orientation of Berkeley's graduate program in sociology which leans more toward the European than the U.S. tradition of postgraduate education. The doctoral student is most likely the principal architect of the research design and sole collector of primary data for the dissertation. The program emphasizes negotiation and a…

  7. Guide to user facilities at the Lawrence Berkeley Laboratory

    SciTech Connect

    Not Available

    1984-04-01

    Lawrence Berkeley Laboratories' user facilities are described. Specific facilities include: the National Center for Electron Microscopy; the Bevalac; the SuperHILAC; the Neutral Beam Engineering Test Facility; the National Tritium Labeling Facility; the 88 inch Cyclotron; the Heavy Charged-Particle Treatment Facility; the 2.5 MeV Van de Graaff; the Sky Simulator; the Center for Computational Seismology; and the Low Background Counting Facility. (GHT)

  8. Berkeley Low Background Facility

    NASA Astrophysics Data System (ADS)

    Thomas, K. J.; Smith, A. R.; Poon, A. W. P.; Chan, Y. D.; Norman, E. B.; Lesko, K. T.

    2015-08-01

    The Berkeley Low Background Facility (BLBF) at Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California provides low background gamma spectroscopy services to a wide array of experiments and projects. The analysis of samples takes place within two unique facilities; locally within a carefully-constructed, low background laboratory on the surface at LBNL and at the Sanford Underground Research Facility (SURF) in Lead, SD. These facilities provide a variety of gamma spectroscopy services to low background experiments primarily in the form of passive material screening for primordial radioisotopes (U, Th, K) or common cosmogenic/anthropogenic products; active screening via neutron activation analysis for U,Th, and K as well as a variety of stable isotopes; and neutron flux/beam characterization measurements through the use of monitors. A general overview of the facilities, services, and sensitivities will be presented. Recent activities and upgrades will also be described including an overview of the recently installed counting system at SURF (recently relocated from Oroville, CA in 2014), the installation of a second underground counting station at SURF in 2015, and future plans. The BLBF is open to any users for counting services or collaboration on a wide variety of experiments and projects.

  9. Berkeley Low Background Facility

    SciTech Connect

    Thomas, K. J.; Norman, E. B.; Smith, A. R.; Poon, A. W. P.; Chan, Y. D.; Lesko, K. T.

    2015-08-17

    The Berkeley Low Background Facility (BLBF) at Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California provides low background gamma spectroscopy services to a wide array of experiments and projects. The analysis of samples takes place within two unique facilities; locally within a carefully-constructed, low background laboratory on the surface at LBNL and at the Sanford Underground Research Facility (SURF) in Lead, SD. These facilities provide a variety of gamma spectroscopy services to low background experiments primarily in the form of passive material screening for primordial radioisotopes (U, Th, K) or common cosmogenic/anthropogenic products; active screening via neutron activation analysis for U,Th, and K as well as a variety of stable isotopes; and neutron flux/beam characterization measurements through the use of monitors. A general overview of the facilities, services, and sensitivities will be presented. Recent activities and upgrades will also be described including an overview of the recently installed counting system at SURF (recently relocated from Oroville, CA in 2014), the installation of a second underground counting station at SURF in 2015, and future plans. The BLBF is open to any users for counting services or collaboration on a wide variety of experiments and projects.

  10. Berkeley's moral philosophy.

    PubMed Central

    Warnock, G

    1990-01-01

    Berkeley held that the moral duty of mankind was to obey God's laws; that--since God was a benevolent Creator--the object of His laws must be to promote the welfare and flourishing of mankind; and that, accordingly, humans could identify their moral duties by asking what system of laws for conduct would in fact tend to promote that object. This position--which is akin to that of 'rule' Utilitarianism--is neither unfamiliar nor manifestly untenable. He was surely mistaken, however, in his further supposition that, if this theory were accepted, the resolution of all (or most) particular moral dilemmas would be simple and straightforward. PMID:2181141

  11. Berkeley Quantitative Genome Browser

    SciTech Connect

    Hechmer, Aaron

    2008-02-29

    The Berkeley Quantitative Genome Browser provides graphical browsing functionality for genomic data organized, at a minimum, by sequence and position. While supporting the annotation browsing features typical of many other genomic browsers, additional emphasis is placed on viewing and utilizing quantitative data. Data may be read from GFF, SGR, FASTA or any column delimited format. Once the data has been read into the browser's buffer, it may be searched. filtered or subjected to mathematical transformation. The browser also supplies some graphical design manipulation functionality geared towards preparing figures for presentations or publication. A plug-in mechanism enables development outside the core functionality that adds more advanced or esoteric analysis capabilities. BBrowse's development and distribution is open-source and has been built to run on Linux, OSX and MS Windows operating systems.

  12. Berkeley automated supernova search

    SciTech Connect

    Kare, J.T.; Pennypacker, C.R.; Muller, R.A.; Mast, T.S.; Crawford, F.S.; Burns, M.S.

    1981-01-01

    The Berkeley automated supernova search employs a computer controlled 36-inch telescope and charge coupled device (CCD) detector to image 2500 galaxies per night. A dedicated minicomputer compares each galaxy image with stored reference data to identify supernovae in real time. The threshold for detection is m/sub v/ = 18.8. We plan to monitor roughly 500 galaxies in Virgo and closer every night, and an additional 6000 galaxies out to 70 Mpc on a three night cycle. This should yield very early detection of several supernovae per year for detailed study, and reliable premaximum detection of roughly 100 supernovae per year for statistical studies. The search should be operational in mid-1982.

  13. Berkeley Quantitative Genome Browser

    2008-02-29

    The Berkeley Quantitative Genome Browser provides graphical browsing functionality for genomic data organized, at a minimum, by sequence and position. While supporting the annotation browsing features typical of many other genomic browsers, additional emphasis is placed on viewing and utilizing quantitative data. Data may be read from GFF, SGR, FASTA or any column delimited format. Once the data has been read into the browser's buffer, it may be searched. filtered or subjected to mathematical transformation.more » The browser also supplies some graphical design manipulation functionality geared towards preparing figures for presentations or publication. A plug-in mechanism enables development outside the core functionality that adds more advanced or esoteric analysis capabilities. BBrowse's development and distribution is open-source and has been built to run on Linux, OSX and MS Windows operating systems.« less

  14. Radicals in Berkeley?

    PubMed Central

    Linn, Stuart

    2015-01-01

    In a previous autobiographical sketch for DNA Repair (Linn, S. (2012) Life in the serendipitous lane: excitement and gratification in studying DNA repair. DNA Repair 11, 595–605), I wrote about my involvement in research on mechanisms of DNA repair. In this Reflections, I look back at how I became interested in free radical chemistry and biology and outline some of our bizarre (at the time) observations. Of course, these studies could never have succeeded without the exceptional aid of my mentors: my teachers; the undergraduate and graduate students, postdoctoral fellows, and senior lab visitors in my laboratory; and my faculty and staff colleagues here at Berkeley. I am so indebted to each and every one of these individuals for their efforts to overcome my ignorance and set me on the straight and narrow path to success in research. I regret that I cannot mention and thank each of these mentors individually. PMID:25713083

  15. Berkeley UXO Discriminator (BUD)

    SciTech Connect

    Gasperikova, Erika; Smith, J. Torquil; Morrison, H. Frank; Becker, Alex

    2007-01-01

    The Berkeley UXO Discriminator (BUD) is an optimally designed active electromagnetic system that not only detects but also characterizes UXO. The system incorporates three orthogonal transmitters and eight pairs of differenced receivers. it has two modes of operation: (1) search mode, in which BUD moves along a profile and exclusively detects targets in its vicinity, providing target depth and horizontal location, and (2) discrimination mode, in which BUD, stationary above a target, from a single position, determines three discriminating polarizability responses together with the object location and orientation. The performance of the system is governed by a target size-depth curve. Maximum detection depth is 1.5 m. While UXO objects have a single major polarizability coincident with the long axis of the object and two equal transverse polarizabilities, scrap metal has three different principal polarizabilities. The results clearly show that there are very clear distinctions between symmetric intact UXO and irregular scrap metal, and that BUD can resolve the intrinsic polarizabilities of the target. The field survey at the Yuma Proving Ground in Arizona showed excellent results within the predicted size-depth range.

  16. Berkeley Disk Resource Manager

    2004-02-27

    The Berkeley Disk Resource Manager (B-DRM) is a middleware component whose function is to provide dynamic space allocation and file management of a shared disk system on the Grid. It provides space allocation and dynamic information on storage availability for the planning and execution of Grid jobs. The B-DRM manages two types of resources: space and files. Vi1en managing space, the B-DRM allocates space to the requesting client based on a default space quota, Thenmore » managing files, the B-DRM allocates space for files, invokes file transfer services to move files into the space, pins files for a certain lifetime, releases files upon the client’s request, and uses file replacement policies to optimize the use of the shared space. The B-DRM is designed to provide effective sharing of files, by monitoring the activity of shared files, and making dynamic decisions on which files to replace when space is needed. In addition, the B-DRM performs automatic garbage collection of unused files when space is needed by removing selected files that were released by the client or whose lifetime has expired. The BDRM supports requests to get multiple files in a single call, manages a queue of the requested files, brings in as many files as the space quota permits, and continues to reuse the space when files are released to stream files to the client until the entire request is satisfied. Similarly, the B-DRM supports requests to put multiple files into its space, streaming files into the allocated space and reusing the space if necessary.« less

  17. Berkeley Disk Resource Manager

    SciTech Connect

    Shoshani, Arie; Sim, Alex; Gu, Junmin

    2004-02-27

    The Berkeley Disk Resource Manager (B-DRM) is a middleware component whose function is to provide dynamic space allocation and file management of a shared disk system on the Grid. It provides space allocation and dynamic information on storage availability for the planning and execution of Grid jobs. The B-DRM manages two types of resources: space and files. Vi1en managing space, the B-DRM allocates space to the requesting client based on a default space quota, Then managing files, the B-DRM allocates space for files, invokes file transfer services to move files into the space, pins files for a certain lifetime, releases files upon the client’s request, and uses file replacement policies to optimize the use of the shared space. The B-DRM is designed to provide effective sharing of files, by monitoring the activity of shared files, and making dynamic decisions on which files to replace when space is needed. In addition, the B-DRM performs automatic garbage collection of unused files when space is needed by removing selected files that were released by the client or whose lifetime has expired. The BDRM supports requests to get multiple files in a single call, manages a queue of the requested files, brings in as many files as the space quota permits, and continues to reuse the space when files are released to stream files to the client until the entire request is satisfied. Similarly, the B-DRM supports requests to put multiple files into its space, streaming files into the allocated space and reusing the space if necessary.

  18. 76 FR 37650 - Safety Zone; 4th of July Festival Berkeley Marina Fireworks Display Berkeley, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-28

    ... SECURITY Coast Guard 33 CFR Part 165 RIN 1625-AA00 Safety Zone; 4th of July Festival Berkeley Marina... Berkeley Pier, Berkeley, CA in support of the 4th of July Festival Berkeley Marina Fireworks Display... used in the fireworks display. Background and Purpose The City of Berkeley Marina will sponsor the...

  19. Free Speech Advocates at Berkeley.

    ERIC Educational Resources Information Center

    Watts, William A.; Whittaker, David

    1966-01-01

    This study compares highly committed members of the Free Speech Movement (FSM) at Berkeley with the student population at large on 3 sociopsychological foci: general biographical data, religious orientation, and rigidity-flexibility. Questionnaires were administered to 172 FSM members selected by chance from the 10 to 1200 who entered and "sat-in"…

  20. SERENDIP: The Berkeley SETI Program

    NASA Astrophysics Data System (ADS)

    Bowyer, Stuart

    UC Berkeley's SERENDIP program is an ongoing effort in the search for extraterrestrial intelligence. It searches for stable narrowband spectral features in the radio frequency spectrum which could conceivably be a signaling beacon sent by an alien civilization. SERENDIP is a backronym 1 for the Search for Extraterrestrial Radio Emissions from Nearby Developed Intelligent Populations.

  1. Molecular Foundry, Berkeley, California (Revised)

    SciTech Connect

    Carlisle, N.

    2008-03-01

    This case study provides information on the Molecular Foundry, which incorporates Labs21 principles in its design and construction. The design includes many of the strategies researched at Lawrence Berkeley Laboratory for energy efficient cleanroom and data centers. The result is an energy efficient high-performing sustainable laboratory.

  2. CLOVERLEAF CYCLOTRON

    DOEpatents

    McMillan, E.M.; Judd, D.L.

    1959-02-01

    A cyclotron is presented embodying a unique magnetic field configuration, which configuration increases in intensity with radius and therefore compensates for the reltivistic mass effect, the field having further convolutions productive of axial stability in the particle beam. By reconciling the seemingly opposed requirements of mass increase compensation on one hand and anial stability on the other, the production of extremely high current particle beams in the relativistie energy range is made feasible. Certain further advantages inhere in the invention, notably an increase in the usable magnet gap, simplified and more efficient extraction of the beam from the accelerator, and ready adaptation to the use of multiply phased excitation as contrasted with the single phased systems herstofore utilized. General

  3. Berkeley, Still the Capital of Desegregation.

    ERIC Educational Resources Information Center

    Wilson, Laval S.

    1980-01-01

    Attempts to demonstrate why the public schools in Berkeley, California could be successfully desegregated. Describes some of the facets of the Berkeley desegregation model and the characteristics of the school system that made it amenable to desegregation. (MK)

  4. Lawrence's Legacy : Seaborg's Cyclotron - The 88-Inch Cyclotron turns 40

    NASA Astrophysics Data System (ADS)

    McMahan, Margaret; Clark, David

    2003-04-01

    In 1958, Sputnik had recently been launched by the Russians, leading to worry in Congress and increased funding for science and technology. Ernest Lawrence was director of the "Rad Lab" at Berkeley. Another Nobel Prize winner, Glenn Seaborg, was Associate Laboratory Director and Director of the Nuclear Chemistry Division. In this atmosphere, Lawrence was phoned by commissioners of the Atomic Energy Commission and asked what they could do for Seaborg, "because he did such a fine job of setting up the chemistry for extracting plutonium from spent reactor fuel" [1]. In this informal way, the 90-Inch (eventually 88-Inch) Cyclotron became a line item in the federal budget at a cost of 3M (later increased to 5M). The 88-Inch Cyclotron achieved first internal beam on Dec. 12, 1961 and first external beam in May 1962. Forty years later it is still going strong. Pieced together from interviews with the retirees who built it, Rad Lab reports and archives from the Seaborg and Lawrence collections, the story of its design and construction - on-time and under-budget - provides a glimpse into the early days of big science. [1] remarks made by Elmer Kelly, "Physicist-in-charge' of the project on the occasion of the 40th anniversary celebration.

  5. Cyclotrons as mass spectrometers

    SciTech Connect

    Clark, D.J.

    1984-04-01

    The principles and design choices for cyclotrons as mass spectrometers are described. They are illustrated by examples of cyclotrons developed by various groups for this purpose. The use of present high energy cyclotrons for mass spectrometry is also described. 28 references, 12 figures.

  6. Environmental Survey preliminary report, Lawrence Berkeley Laboratory, Berkeley, California

    SciTech Connect

    Not Available

    1988-07-01

    The purpose of this report is to present the preliminary findings made during the Environmental Survey, February 22--29, 1988, at the US Department of Energy (DOE) Lawrence Berkeley Laboratory (LBL) in Berkeley, California. The University of California operates the LBL facility for DOE. The LBL Survey is part of the larger DOE-wide Environmental Survey announced by Secretary John S. Herrington on September 18, 1985. The purpose of this effort is to identify, via no fault'' baseline Surveys, existing environmental problems and areas of environmental risk at DOE facilities, and to rank them on a DOE wide basis. This ranking will enable DOE to more effectively establish priorities for addressing environmental problems and allocate the resources necessary to correct them. Because the Survey is no fault'' and is not an audit,'' it is not designed to identify specific isolated incidents of noncompliance or to analyze environmental management practices. Such incidents and/or management practices will, however, be used in the Survey as a means of identifying existing and potential environmental problems. The LBL Survey was conducted by a multidisciplinary team of technical specialists headed and managed by a Team Leader and Assistant Team Leader from DOE's Office of Environmental Audit. A complete list of the LBL Survey participants and their affiliations is provided in Appendix A. 80 refs., 27 figs., 37 tabs.

  7. Synchrotrons in cyclotron territory

    SciTech Connect

    Clark, D.J.; Gough, R.A.

    1986-10-01

    Synchrotrons and cyclotrons have an overlap in their particle and energy ranges. In proton radiotherapy, synchrotrons are proposed at 250 MeV, an energy usually served by cyclotrons. Heavy ion therapy has been synchrotron territory, but cyclotrons may be competitive. In nuclear science, heavy ion synchrotrons can be used in the cyclotron energy range of 10-200 MeV/u. Storage rings are planned to increase the flexibility of several cyclotrons. For atomic physics research, several storage rings are under construction for the energy range of 10 MeV/u and below.

  8. 77 FR 37604 - Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-22

    ... SECURITY Coast Guard 33 CFR Part 165 Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA... enforce the safety zone for the Berkeley Marina Fourth of July Fireworks display in the Captain of the... necessary to protect life and property of the maritime public from the hazards associated with the...

  9. 78 FR 29022 - Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-05-17

    ... SECURITY Coast Guard 33 CFR Part 165 Safety Zone; Fourth of July Fireworks, Berkeley Marina, Berkeley, CA... enforce the safety zone for the Berkeley Marina Fourth of July Fireworks display in the Captain of the... necessary to protect life and property of the maritime public from the hazards associated with the...

  10. Radiation effects testing at the 88-inch cyclotron at LBNL

    SciTech Connect

    McMahan, Margaret A.; Koga, Rokotura

    2001-10-09

    The effects of ionizing particles on sensitive microelectronics is an important component of the design of systems as diverse as satellites and space probes, detectors for high energy physics experiments and even internet server farms. Understanding the effects of radiation on human cells is an equally important endeavor directed towards future manned missions in space and towards cancer therapy. At the 88-Inch Cyclotron at the Berkeley Laboratory, facilities are available for radiation effects testing (RET) with heavy ions and with protons. The techniques for doing these measurements and the advantages of using a cyclotron will be discussed, and the Cyclotron facilities will be compared with other facilities worldwide. RET of the same part at several facilities of varying beam energy can provide tests of the simple models used in this field and elucidate the relative importance of atomic and nuclear effects. The results and implications of such measurements will be discussed.

  11. Lawrence Berkeley Lab Indexing Toolbox

    2003-09-08

    The Lawrence Berkeley Lab Indexing Toolbox is intended to be used in the context of X-ray crystallography experiments involving biological macromolecules. Macromolecules such as proteins form 3-dimensional periodic arrays (crystal) which in turn lead to lattice-like diffraction patterns when the crystal sample is irradiated with collimated X-rays from a synchrotron or other X-ray source. Once the diffraction pattern is captured on an imaging device the next step is to deduce the periodic nature of themore » crystal sample, along with its internal symmetry. this analysis, known as "indexing" is a well-studied problem. However, there are no other implementations designed to operate in an automated setting, in which the human experimentalist is not prosent to manually verify the results of indexing. In particular LABELIT uses three novel algorithms to facilitate automation: a more robust way to verify the position of the incident X-ray beam on the image, a better way to verify that the deduced lattice is consistent with the observed crystal lattice, and new method to deduce the internal symmetry from measurements of the lattice. Moreover, the algorithms are implemented in a Python framework that permits indexing to fail (in rare cases) without crashing the program, thus allowing the software to be incorporated in robotic systems where unattended operation is expected. It will be especially useful for high throughput operations at snychrotron beamlines.« less

  12. Imaging using accelerated heavy ions

    SciTech Connect

    Chu, W.T.

    1982-05-01

    Several methods for imaging using accelerated heavy ion beams are being investigated at Lawrence Berkeley Laboratory. Using the HILAC (Heavy-Ion Linear Accelerator) as an injector, the Bevalac can accelerate fully stripped atomic nuclei from carbon (Z = 6) to krypton (Z = 34), and partly stripped ions up to uranium (Z = 92). Radiographic studies to date have been conducted with helium (from 184-inch cyclotron), carbon, oxygen, and neon beams. Useful ranges in tissue of 40 cm or more are available. To investigate the potential of heavy-ion projection radiography and computed tomography (CT), several methods and instrumentation have been studied.

  13. The Berkeley Digital Seismic Network

    NASA Astrophysics Data System (ADS)

    Romanowicz, B.; Dreger, D.; Neuhauser, D.; Karavas, W.; Hellweg, M.; Uhrhammer, R.; Lombard, P.; Friday, J.; Lellinger, R.; Gardner, J.; McKenzie, M. R.; Bresloff, C.

    2007-05-01

    Since it began monitoring earthquakes in northern California 120 years ago, the Berkeley Seismological Laboratory (BSL) has been striving to produce the highest quality and most complete seismic data possible in the most modern way. This goal has influenced choices in instrumentation, installation and telemetry, as well as the investment in expertise and manpower. Since the transition to broadband (BB) instrumentation in the mid- 1980s and to a fully digitally telemetered network in the early 1990s, we have continued these efforts. Each of our 25 BB installations includes three component BB seismometers (STS-1s or STS-2) and digital accelerometers to capture the full range of ground motion from distant teleseisms to large, nearby earthquakes (almost 250 dB). The ground motion is recorded on-site by 24 bit dataloggers. Additional environmental parameters, such as temperature and pressure, are also monitored continuously. Many stations record also C-GPS data that is transmitted continuously to the BSL via shared real-time telemetry. The BDSN's first stations were installed in abandoned mines. In the last 15 years, we developed installations using buried shipping containers to reduce environmental noise and provide security and easy access to the equipment. Data are transmitted in real-time at several sampling rates to one or more processing centers, using frame relay, radio, microwave, and/or satellite. Each site has 7-30 days of onsite data storage to guard against data loss during telemetry outages. Each station is supplied with backup batteries to provide power for 3 days. The BDSN real-time data acquisition, earthquake analysis and archiving computers are housed in a building built to "emergency grade" seismic standards, with air conditioning and power backed up by a UPS and a large generator. Data latency and power are monitored by automated processes that alert staff via pager and email. Data completeness and timing quality are automatically assessed on a daily

  14. Berkeley Researchers Create an Invisibility Cloak

    SciTech Connect

    2009-01-01

    A team led by Xiang Zhang, a principal investigator with Berkeley Labs Materials Sciences Division and director of UC Berkeley's Nano-scale Science and Engineering Center, has created a carpet cloak from nanostructured silicon that conceals the presence of objects placed under it from optical detection. (Video by Jensen Li) http://newscenter.lbl.gov/feature-stories/2009/05/01/invisibility-cloak/

  15. Star Formation near Berkeley 59: Embedded Protostars

    NASA Astrophysics Data System (ADS)

    Rosvick, J. M.; Majaess, D.

    2013-12-01

    A group of suspected protostars in a dark cloud northwest of the young (~2 Myr) cluster Berkeley 59 and two sources in a pillar south of the cluster have been studied in order to determine their evolutionary stages and ascertain whether their formation was triggered by Berkeley 59. Narrowband near-infrared observations from the Observatoire du Mont Mégantic, 12CO (J = 3-2) and SCUBA-2 (450 and 850 μm) observations from the JCMT, 2MASS, and WISE images, and data extracted from the IPHAS survey catalog were used. Of 12 sources studied, two are Class I objects, while three others are flat/Class II, one of which is a T Tauri candidate. A weak CO outflow and two potential starless cores are present in the cloud, while the pillar possesses substructure at different velocities, with no outflows present. The CO spectra of both regions show peaks in the range v LSR = -15 to -17 km s-1, which agrees with the velocity adopted for Berkeley 59 (-15.7 km s-1), while spectral energy distribution models yield an average interstellar extinction AV and distance of 15 ± 2 mag and 830 ± 120 pc, respectively, for the cloud, and 6.9 mag and 912 pc for the pillar, indicating that the regions are in the same vicinity as Berkeley 59. The formation of the pillar source appears to have been triggered by Berkeley 59. It is unclear whether Berkeley 59 triggered the association's formation.

  16. Cyclotron Institute Upgrade Project

    SciTech Connect

    Clark, Henry; Yennello, Sherry; Tribble, Robert

    2014-08-26

    The Cyclotron Institute at Texas A&M University has upgraded its accelerator facilities to extend research capabilities with both stable and radioactive beams. The upgrade is divided into three major tasks: (1) re-commission the K-150 (88”) cyclotron, couple it to existing beam lines to provide intense stable beams into the K-500 experimental areas and use it as a driver to produce radioactive beams; (2) develop light ion and heavy ion guides for stopping radioactive ions created with the K-150 beams; and (3) transport 1+ ions from the ion guides into a charge-breeding electron-cyclotron-resonance ion source (CB-ECR) to produce highly-charged radioactive ions for acceleration in the K-500 cyclotron. When completed, the upgraded facility will provide high-quality re-accelerated secondary beams in a unique energy range in the world.

  17. The anticentre old open clusters Berkeley 27, Berkeley 34 and Berkeley 36: new additions to the BOCCE project

    NASA Astrophysics Data System (ADS)

    Donati, P.; Bragaglia, A.; Cignoni, M.; Cocozza, G.; Tosi, M.

    2012-08-01

    In this paper, we present the investigation of the evolutionary status of three open clusters: Berkeley 27, Berkeley 34 and Berkeley 36, all located in the Galactic anticentre direction. All of them were observed with SUperb Seeing Imager 2 at the New Technology Telescope using the Bessel B, V and I filters. The cluster parameters have been obtained using the synthetic colour-magnitude diagram (CMD) method, i.e. the direct comparison of the observational CMDs with a library of synthetic CMDs generated with different evolutionary sets (Padova, FRANEC and FST). This analysis shows that Berkeley 27 has an age between 1.5 and 1.7 Gyr, a reddening E(B-V) in the range 0.40-0.50 and a distance modulus (m-M)0 between 13.1 and 13.3; Berkeley 34 is older with an age in the range 2.1-2.5 Gyr, E(B-V) between 0.57 and 0.64 and (m-M)0 between 14.1 and 14.3; Berkeley 36, with an age between 7.0 and 7.5 Gyr, has a reddening of E(B-V) ˜ 0.50 and a distance modulus (m-M)0 between 13.1 and 13.2. For all the clusters, our analysis suggests a subsolar metallicity in accord with their position in the outer Galactic disc. This work is based on data collected at the European Southern Observatory (ESO) telescopes under programme 076.D-0119.

  18. Berkeley Unified Parallel C (UPC) Compiler

    2003-04-06

    This program is a portable, open-source, compiler for the UPC language, which is based on the Open64 framework, and has extensive support for optimizations. This compiler operated by translating UPC into ANS/ISO C for compilation by a native compiler and linking with a UPC Runtime Library. This design eases portability to both shared and distributed memory parallel architectures. For proper operation the "Berkeley Unified Parallel C (UPC) Runtime Library" and its dependencies are required. Compatiblemore » replacements which implement "The Berkeley UPC Runtime Specification" are possible.« less

  19. Spatial cyclotron damping

    NASA Technical Reports Server (NTRS)

    Olson, C. L.

    1970-01-01

    To examine spatial electron cyclotron damping in a uniform Vlasov plasma, it is noted that the plasma response to a steady-state transverse excitation consists of several terms (dielectric-pole, free-streaming, and branch-cut), but that the cyclotron-damped pole term is the dominant term for z l = c/w sub ce provided (w sub pe/w sub ce) squared (c/a) is much greater than 1. If the latter inequality does not hold, then the free-streaming and branch-cut terms persist well past z = c/w sub ce as w sub 1 approaches w sub ce, making experimental measurement of cyclotron damping essentially impossible. Considering only (w sub pe/w sub ce) squared (c/a) is much greater than 1, it is shown how collisional effects should be estimated and how a finite-width excitation usually has little effect on the cyclotron-damped part of the response. Criteria is established concerning collisional damping, measurable damping length sizes, and allowed uncertainty in the magnetic field Beta. Results of numerical calculations, showing the regions in the appropriate parameter spaces that meet these criteria, are presented. From these results, one can determine the feasibility of, or propose parameter values for, an experiment designed to measure spatial cyclotron damping. It is concluded that the electron temperature T sub e should be at least 1 ev., and preferably 10 ev. or higher, for a successful experiment.

  20. Ernest Orlando Berkeley National Laboratory - Fundamental and applied research on lean premixed combustion

    SciTech Connect

    Cheng, Robert K.

    1999-07-07

    Ernest Orland Lawrence Berkeley National Laboratory (Berkeley Lab) is the oldest of America's national laboratories and has been a leader in science and engineering technology for more than 65 years, serving as a powerful resource to meet Us national needs. As a multi-program Department of Energy laboratory, Berkeley Lab is dedicated to performing leading edge research in the biological, physical, materials, chemical, energy, environmental and computing sciences. Ernest Orlando Lawrence, the Lab's founder and the first of its nine Nobel prize winners, invented the cyclotron, which led to a Golden Age of particle physics and revolutionary discoveries about the nature of the universe. To this day, the Lab remains a world center for accelerator and detector innovation and design. The Lab is the birthplace of nuclear medicine and the cradle of invention for medical imaging. In the field of heart disease, Lab researchers were the first to isolate lipoproteins and the first to determine that the ratio of high density to low density lipoproteins is a strong indicator of heart disease risk. The demise of the dinosaurs--the revelation that they had been killed off by a massive comet or asteroid that had slammed into the Earth--was a theory developed here. The invention of the chemical laser, the unlocking of the secrets of photosynthesis--this is a short preview of the legacy of this Laboratory.

  1. Berkeley Lab's Cool Your School Program

    SciTech Connect

    Ivan Berry

    2012-07-30

    Cool Your School is a series of 6th-grade, classroom-based, science activities rooted in Berkeley Lab's cool-surface and cool materials research and aligned with California science content standards. The activities are designed to build knowledge, stimulate curiosity, and carry the conversation about human-induced climate change, and what can be done about it, into the community.

  2. SERENDIP - The UC Berkeley SETI project

    NASA Astrophysics Data System (ADS)

    Donnelly, C.; Bowyer, S.; Werthimer, D.; Malina, R. F.

    1993-10-01

    The UC Berkeley SERENDIP (search for extraterrestrial radio emissions from nearby developed intelligent populations) SETI project searches for narrow band radio signals from extraterrestrial civilizations. The search is based on a piggyback data acquisition system and an off-line data analysis system. The SERENDIP systems are described and progress is reviewed.

  3. Berkeley Lab's Cool Your School Program

    ScienceCinema

    Ivan Berry

    2013-06-24

    Cool Your School is a series of 6th-grade, classroom-based, science activities rooted in Berkeley Lab's cool-surface and cool materials research and aligned with California science content standards. The activities are designed to build knowledge, stimulate curiosity, and carry the conversation about human-induced climate change, and what can be done about it, into the community.

  4. Reorganizing the Biological Sciences at Berkeley.

    ERIC Educational Resources Information Center

    Trow, Martin A.

    1983-01-01

    The University of California at Berkeley's substantial reorganization of the biological sciences due to internal and external needs is chronicled, focusing on the coordinated efforts of the institution and the strong, supportive leadership of the chancellor. The story is presented as an unusual case of institutional leadership within a highly…

  5. Berkeley Lab 2nd Grader Outreach

    ScienceCinema

    Scoggins, Jackie; Louie, Virginia

    2013-05-29

    The Berkeley Lab IT Department sponsored a community outreach program aimed at teaching young children about computers and networks. Second graders from LeConte Elementary School joined Lab IT Staff for a day of in-depth exercises and fun.

  6. Berkeley, California: Solar in Action (Brochure)

    SciTech Connect

    Not Available

    2011-10-01

    This brochure provides an overview of the challenges and successes of Berkeley, CA, a 2007 Solar America City awardee, on the path toward becoming a solar-powered community. Accomplishments, case studies, key lessons learned, and local resource information are given.

  7. Berkeley Lab 2nd Grader Outreach

    SciTech Connect

    Scoggins, Jackie; Louie, Virginia

    2012-01-01

    The Berkeley Lab IT Department sponsored a community outreach program aimed at teaching young children about computers and networks. Second graders from LeConte Elementary School joined Lab IT Staff for a day of in-depth exercises and fun.

  8. Chapel Hill, Berkeley Head Graduate Rankings.

    ERIC Educational Resources Information Center

    Chemical and Engineering News, 1983

    1983-01-01

    Provides lists ranking the 25 largest producers of bachelor's, certified bachelor's, master's, and doctoral graduates in chemistry. University of North Carolina (Chapel Hill) is the nation's largest producer of bachelor's degree chemistry graduates while the University of California (Berkeley) is the largest producer of Ph.D. chemistry graduates.…

  9. High intensity ion beam injection into the 88-inch cyclotron

    SciTech Connect

    Wutte, Daniela; Clark, Dave J.; Laune, Bernard; Leitner,Matthaeus A.; Lyneis, Claude M.

    2000-05-31

    Low cross section experiments to produce super-heavyelements have increased the demand for high intensity heavy ion beams atenergies of about 5 MeV/nucleon at the 88-Inch Cyclotron at the LawrenceBerkeley National Laboratory. Therefore, efforts are underway to increasethe overall ion beam transmission through the axial injection line andthe cyclotron. The ion beam emittance has been measured for various ionmasses and charge states. Beam transport simulations including spacecharge effects were performed for both of the injection line and the ionsource extraction. The relatively low nominal injection voltage of 10 kVwas found to be the main factor for ion beam losses, because of beam blowup due to space charge forces at higher intensities. Consequently,experiments and simulations have been performed at higherinjectionenergies, and it was demonstrated that the ion beams could still becentered in the cyclotron at these energies. Therefore, the new injectorion source VENUS and its ion beam transport system (currently underconstruction at the 88-Inch Cyclotron) are designed for extractionvoltages up to 30 kV.

  10. THE YOUNG OPEN CLUSTER BERKELEY 55

    SciTech Connect

    Negueruela, Ignacio; Marco, Amparo E-mail: amparo.marco@ua.es

    2012-02-15

    We present UBV photometry of the highly reddened and poorly studied open cluster Berkeley 55, revealing an important population of B-type stars and several evolved stars of high luminosity. Intermediate-resolution far-red spectra of several candidate members confirm the presence of one F-type supergiant and six late supergiants or bright giants. The brightest blue stars are mid-B giants. Spectroscopic and photometric analyses indicate an age 50 {+-} 10 Myr. The cluster is located at a distance d Almost-Equal-To 4 kpc, consistent with other tracers of the Perseus Arm in this direction. Berkeley 55 is thus a moderately young open cluster with a sizable population of candidate red (super)giant members, which can provide valuable information about the evolution of intermediate-mass stars.

  11. Lawrence Berkeley Laboratory laser-transmission method

    SciTech Connect

    Rosen, H.; Novakov, T.

    1981-08-01

    The Lawrence Berkeley Laboratory laser transmission method has been used to determine the absorption coefficients of aerosol particles generated at the First International Workshop on Light Absorption. Analysis of the results confirms that the optical attenuation measurement is insensitive to the scattering properties of the aerosol. A simple model calculation is presented which explains these observations and points out the critical role of the filter substrate as an almost perfect diffuse reflector in the technique.

  12. Berkeley Lab Computing Sciences: Accelerating Scientific Discovery

    SciTech Connect

    Hules, John A

    2008-12-12

    Scientists today rely on advances in computer science, mathematics, and computational science, as well as large-scale computing and networking facilities, to increase our understanding of ourselves, our planet, and our universe. Berkeley Lab's Computing Sciences organization researches, develops, and deploys new tools and technologies to meet these needs and to advance research in such areas as global climate change, combustion, fusion energy, nanotechnology, biology, and astrophysics.

  13. C. Judson King of UC Berkeley

    SciTech Connect

    Prausnitz, John

    2005-06-01

    In the middle of the UC Berkeley campus, next to the Main Library, South Hall is the last surviving building from the original campus, founded about 135 years ago. A tiny tree-shaded appendix to this venerated classical building houses Berkeley's Center for Studies in Higher Education, directed by C. Judson King, former Provost and Senior Vice President--Academic Affairs of the ten-campus University of California and long-time Professor of Chemical Engineering at Berkeley. Jud came to Berkeley in 1963 as assistant professor of chemical engineering, following receipt of a doctor's degree from MIT and a subsequent short appointment as director of the MIT chemical engineering practice school station at what was then Esso (now Exxon) in New Jersey. His undergraduate degree is from Yale. Starting with his MIT doctoral dissertation on gas absorption, Jud has devoted much of his professional career to separation processes. His teaching and research activities have been primarily concerned with separation of mixtures with emphasis on liquid-liquid extraction and drying. As a consultant to Procter and Gamble, he contributed to the technology of making instant coffee. His life-long activities in hiking and camping stimulated Jud's interest in the manufacture of freeze-dried foods (e.g. turkey meat) to minimize the weight of his hiking back-pack. Jud is internationally known not only for his many research publications but even more, for his acclaimed textbook ''Separation Processses'' (McGraw-Hill, second edition 1980) that is used in standard chemical engineering courses in the US and abroad.

  14. Lawrence Berkeley Laboratory 1993 Site Environmental Report

    SciTech Connect

    Not Available

    1994-05-01

    This annual Site Environmental Report summarizes Lawrence Berkeley Laboratory`s (LBL`s) environmental activities in calendar year (CY) 1993. The purpose of this report is to characterize site environmental management performance, confirm compliance status with environmental standards and requirements, and highlight significant programs and efforts. Its format and content are consistent with the requirements of the US Department of Energy (DOE) Order 5400.1, General Environmental Protection Program.

  15. The geothermal program at Lawrence Berkeley Laboratory

    SciTech Connect

    Lippmann, M.J.

    1987-06-01

    The main purpose of the geothermal program at Lawrence Berkeley Laboratory is to develop, improve and validate methods and instrumentation to: (1) determine geothermal reservoir parameters; (2) detect and characterize reservoir fractures and boundaries; and (3) identify and evaluate the importance of reservoir processes. The ultimate objective of the program, which includes field, theoretical and modeling activities, is to advance the state-of-the-art for characterizing geothermal systems and evaluating their productive capacity and longevity under commercial exploitation.

  16. Technology transfer at Lawrence Berkeley Laboratory

    SciTech Connect

    Johnson, D.

    1992-09-01

    Lawrence Berkeley Laboratory (LBL) is dedicated to commercializing new technology in such fields as advanced materials, biotechnology, and electronics. Technology transfer between national laboratories and the industrial community is important in maintaining America's competitive edge. This document examines opportunities to establish working relationships with LBL. Streamlined methods for technology transfer are available with the aid of the Technology Transfer Department and the Patent Department at LBL. Research activities at LBL are concentrated in three major program areas: Energy Sciences, General Sciences, and Biosciences. Each program area consists of three research divisions. LBL welcomes both requests for information and proposals to conduct research.

  17. Technology transfer at Lawrence Berkeley Laboratory

    SciTech Connect

    Johnson, D.

    1992-09-01

    Lawrence Berkeley Laboratory (LBL) is dedicated to commercializing new technology in such fields as advanced materials, biotechnology, and electronics. Technology transfer between national laboratories and the industrial community is important in maintaining America`s competitive edge. This document examines opportunities to establish working relationships with LBL. Streamlined methods for technology transfer are available with the aid of the Technology Transfer Department and the Patent Department at LBL. Research activities at LBL are concentrated in three major program areas: Energy Sciences, General Sciences, and Biosciences. Each program area consists of three research divisions. LBL welcomes both requests for information and proposals to conduct research.

  18. Microbes to Biomes at Berkeley Lab

    SciTech Connect

    2015-10-28

    Microbes are the Earth's most abundant and diverse form of life. Berkeley Lab's Microbes to Biomes initiative -- which will take advantage of research expertise at the Joint Genome Institute, Advanced Light Source, Molecular Foundry, and the new computational science facility -- is designed to explore and reveal the interactions of microbes with one another and with their environment. Microbes power our planet’s biogeochemical cycles, provide nutrients to our plants, purify our water and are integral components in keeping the human body free of disease and may hold the key to the Earth’s future.

  19. Lawrence Berkeley Laboratory 1994 site environmental report

    SciTech Connect

    1995-05-01

    The 1994 Site Environmental Report summarizes environmental activities at Lawrence Berkeley Laboratory (LBL) for the calendar year (CY) 1994. The report strives to present environmental data in a manner that characterizes the performance and compliance status of the Laboratory`s environmental management programs when measured against regulatory standards and DOE requirements. The report also discusses significant highlight and planning efforts of these programs. The format and content of the report are consistent with the requirements of the U.S. Department of Energy (DOE) Order 5400.1, General Environmental Protection Program.

  20. Careers in Data Science: A Berkeley Perspective

    NASA Astrophysics Data System (ADS)

    Koy, K.

    2015-12-01

    Last year, I took on an amazing opportunity to serve as the Executive Director of the new Berkeley Institute for Data Science (BIDS). After a 15-year career working with geospatial data to advance our understanding of the environment, I have been presented with a unique opportunity through BIDS to work with talented researchers from a wide variety of backgrounds. Founded in 2013, BIDS is a central hub of research and education at UC Berkeley designed to facilitate and nurture data-intensive science. We are building a community centered on a cohort of talented data science fellows and senior fellows who are representative of the world-class researchers from across our campus and are leading the data science revolution within their disciplines. Our initiatives are designed to bring together broad constituents of the data science community, including domain experts from the life, social, and physical sciences and methodological experts from computer science, statistics, and applied mathematics. While many of these individuals rarely cross professional paths, BIDS actively seeks new and creative ways to engage and foster collaboration across these different research fields. In this presentation, I will share my own story, along with some insights into how BIDS is supporting the careers of data scientists, including graduate students, postdocs, faculty, and research staff. I will also describe how these individuals we are helping support are working to address a number of data science-related challenges in scientific research.

  1. Berkeley Unified Parallel C (UPC) Runtime Library

    2003-03-31

    This software comprises a portable, open source implementation of a runtime library to support applications written in the Unified Parallel C (UPC) language. This library implements the UPC-specific functionality, including shared memory allocation and locks. The network-dependent functionality is implemented as a thin wrapper around a separate library implementing the GASNet (Global-Address Space Networking) specification. For true shared memory machines. GASNet is bypassed in favor of direct memory operations and local synchronization mechanisms. The Berkeleymore » UPC Runtime Library is currently the only implementation of the "Berkeley UPC Runtime Specification", and thus the only runtme library usable with the Berkeley UPC Compiler. Also, it is the only UPC runtime known to the author to provide two shared pointer representations: one for arbitrary blocksizes and one to optimize for the common cases of phaseless and blocksize=1. For distributed memory environments a library implementing the GASNet (Global-Address Space Networking) specification is required for communication. While no specialized hardware is required, a high-speed interconnet supported by the GASNet implementation is suggested for preformance. If no supported high-speed interconnect is available. GASNet can run over MPI. An external library is reqired for certain local memory allocation operations. A well defined interface allows for multiple implementations of this library, but at present the "umalloc" library from LBNL is the only compatible implementation.« less

  2. Cyclotrons and positron emitting radiopharmaceuticals

    SciTech Connect

    Wolf, A.P.; Fowler, J.S.

    1984-01-01

    The state of the art of Positron Emission Tomography (PET) technology as related to cyclotron use and radiopharmaceutical production is reviewed. The paper discusses available small cyclotrons, the positron emitters which can be produced and the yields possible, target design, and radiopharmaceutical development and application. 97 refs., 12 tabs. (ACR)

  3. Ion cyclotron resonance cell

    DOEpatents

    Weller, R.R.

    1995-02-14

    An ion cyclotron resonance cell is disclosed having two adjacent sections separated by a center trapping plate. The first section is defined by the center trapping plate, a first end trapping plate, and excitation and detector electrodes. The second section includes a second end trapping plate spaced apart from the center plate, a mirror, and an analyzer. The analyzer includes a wavelength-selective light detector, such as a detector incorporating an acousto-optical device (AOD) and a photodetector. One or more ion guides, grounded plates with holes for the ion beam, are positioned within the vacuum chamber of the mass spectrometer between the ion source and the cell. After ions are trapped and analyzed by ion cyclotron resonance techniques in the first section, the ions of interest are selected according to their mass and passed into the second section for optical spectroscopic studies. The trapped ions are excited by light from a laser and caused thereby to fluoresce. The fluorescent light emitted by the excited ions is reflected by the mirror and directed onto the detector. The AOD is scanned, and the photodetector output is recorded and analyzed. The ions remain in the second section for an extended period, enabling multiple studies to be carried out on the same ensemble of ions. 5 figs.

  4. Ion cyclotron resonance cell

    DOEpatents

    Weller, Robert R.

    1995-01-01

    An ion cyclotron resonance cell having two adjacent sections separated by a center trapping plate. The first section is defined by the center trapping plate, a first end trapping plate, and excitation and detector electrodes. The second section includes a second end trapping plate spaced apart from the center plate, a mirror, and an analyzer. The analyzer includes a wavelength-selective light detector, such as a detector incorporating an acousto-optical device (AOD) and a photodetector. One or more ion guides, grounded plates with holes for the ion beam, are positioned within the vacuum chamber of the mass spectrometer between the ion source and the cell. After ions are trapped and analyzed by ion cyclotron resonance techniques in the first section, the ions of interest are selected according to their mass and passed into the second section for optical spectroscopic studies. The trapped ions are excited by light from a laser and caused thereby to fluoresce. The fluorescent light emitted by the excited ions is reflected by the mirror and directed onto the detector. The AOD is scanned, and the photodetector output is recorded and analyzed. The ions remain in the second section for an extended period, enabling multiple studies to be carried out on the same ensemble of ions.

  5. Cyclotron produced radiopharmaceuticals

    NASA Astrophysics Data System (ADS)

    Kopička, K.; Fišer, M.; Hradilek, P.; Hanč, P.; Lebeda, O.

    2003-01-01

    Some of the cyclotron-produced radionuclides may serve as important materials for the production of radiopharmaceuticals. This lecture deals with basic information relating to various aspects of these compounds. In comparison with radionuclides/compounds used for non-medical purposes, radiopharmaceuticals are subject to a broader scale of regulations, both from the safety and efficacy point of view; besides that, there are both radioactive and medical aspects that must be taken into account for any radiopharmaceutical. According to the regulations and in compliance with general rules of work with radioactivity, radiopharmaceuticals should only be prepared/manufactured under special conditions, using special areas and special equipment and applying special procedures (e.g. sterilisation, disinfection, aseptic work). Also, there are special procedures for cleaning and maintenance. Sometimes the requirements for the product safety clash with those for the safety of the personnel; several examples of solutions pertaining to these cases are given in the lecture. Also, the specific role of cyclotron radiopharmaceuticals is discussed.

  6. JSW's baby cyclotron

    SciTech Connect

    Toda, Y.; Kaneda, Y.; Satoh, Y.; Suzukawa, I.; Yamada, T.

    1983-04-01

    Designed by The Japan Steel Works, Ltd., specially for installation in a hospital's medical department and nuclear research laboratory, '' JSW BABY CYCLOTRON '' has been developed to produce short-lived radioisotopes such as 11C, 13N, 15O and 18F. JSW's Baby Cyclotron has some design features. 1) Fixed energy and four sector azimuthally varying field. 2) Compact figure desired for hospital's nuclear medical department 3) A bitter type magnet yoke shielding activity 4) Simple control and operation 5) Easy maintenance without skilled personnel. Type BC105 (P:10MeV, d:5MeV), BC107 (P:10MeV, d:7MeV), BC168 (P:16MeV, d:8MeV) and BC1710 (P:17MeV, d:10MeV) are available according to required amount of radioisotopes. In our radioisotope production test, yield and purity of 11C, 13N, 15O and 18F are usable to clinical diagnosis.

  7. Ernest Orlando Lawrence (1901-1958), Cyclotron and Medicine

    SciTech Connect

    Chu, William T.

    2005-09-01

    On August 8, 2001, Lawrence Berkeley National Laboratory celebrated the centennial of the birth of its founder (and namesake), Ernest Orlando Lawrence. For the occasion, many speeches were given and old speeches were remembered. We recall the words of the late Luis Alvarez, a Nobel Laureate and one of the Lawrence's closest colleagues: ''Lawrence will always be remembered as the inventor of the cyclotron, but more importantly, he should be remembered as the inventor of the modern way of doing science''. J. L. Heilbron and R. W. Seidel, in the introduction of their book, ''Lawrence and His Laboratory'' stated, ''The motives and mechanisms that shaped the growth of the Laboratory helped to force deep changes in the scientific estate and in the wider society. In the entrepreneurship of its founder, Ernest Orlando Lawrence, these motives, mechanisms, and changes came together in a tight focus. He mobilized great and small philanthropists, state and local governments, corporations, and plutocrats, volunteers and virtuosos. The work they supported, from astrophysics and atomic bombs, from radiochemistry to nuclear medicine, shaped the way we observe, control, and manipulate our environment.'' Indeed, all over the civilized world, the ways we do science changed forever after Lawrence built his famed Radiation Laboratory. In this editorial, we epitomize his legacy of changing the way we do medicine, thereby affecting the health and well being of all humanity. This year marks the 75th anniversary of the invention of the cyclotron by Ernest Orlando Lawrence at the University of California at Berkeley. Lawrence conceived the idea of the cyclotron early in 1929 after reading an article by Rolf Wideroe on high-energy accelerators. In the spring of 1930 one of his students, Nels Edlefsen, constructed two crude models of a cyclotron. Later in the fall of the same year, another student, M. Stanley Livingston, constructed a 13-cm diameter model that had all the features of early

  8. The Berkeley extreme ultraviolet calibration facility

    NASA Technical Reports Server (NTRS)

    Welsh, Barry Y.; Jelinsky, Patrick; Malina, Roger F.

    1988-01-01

    The vacuum calibration facilities of the Space Sciences Laboratory, University of California at Berkeley are designed for the calibration and testing of EUV and FUV spaceborne instrumentation (spectral range 44-2500 A). The facility includes one large cylindrical vacuum chamber (3 x 5 m) containing two EUV collimators, and it is equipped with a 4-axis manipulator of angular-control resolution 1 arcsec for payloads weighing up to 500 kg. In addition, two smaller cylindrical chambers, each 0.9 x 1.2 m, are available for vacuum and thermal testing of UV detectors, filters, and space electronics hardware. All three chambers open into class-10,000 clean rooms, and all calibrations are referred to NBS secondary standards.

  9. ORFEUS-SPAS - The Berkeley EUV spectrometer

    NASA Technical Reports Server (NTRS)

    Bowyer, Stuart; Hurwitz, Mark

    1990-01-01

    The Berkeley EUV spectrometer of ORFEUS-SPAS, a joint project of NASA and the BMFT, incorporates a set of four novel spherically figured, varied line-space gratings used in a geometry that is similar to that of the classic Rowland mount to span an interval of 390 and 1200 A. Two spectral detector units containing curved microchannel plates and delay-line anodes encode the arriving photons in digital format for telemetry. An additional optic directs the image of the source in the entrance aperture onto a sealed FUV detector which is used to track the source as it drifts during an observation, enabling a postflight reconstruction of the spacecraft pointing vector. This in turn makes it possible to define with precision the wavelength of each recorded photon.

  10. Telescience at the University of California, Berkeley

    NASA Technical Reports Server (NTRS)

    Chakrabarti, S.; Marchant, W. T.; Kaplan, G. C.; Dobson, C. A.; Jernigan, J. G.

    1988-01-01

    The University of California at Berkeley (UCB) is a member of a university consortium involved in telescience testbed activities under the sponsorship of NASA. The Telescience Testbed Project consists of three experiments using flight hardware being developed for the Extreme Ultraviolet Explorer project at UCB's Space Sciences Laboratory. The first one is a teleoperation experiment investigating remote instrument control using a computer network such as the Internet. The second experiment is an effort to develop a system for operation of a network of remote workstations allowing coordinated software development, evaluation, and use by widely dispersed groups. The final experiment concerns simulation as a method to facilitate the concurrent development of instrument hardware and support software. Progress in these areas is described.

  11. The Coronal Ultraviolet Berkeley Spectrometer (CUBS)

    NASA Technical Reports Server (NTRS)

    Bush, Brett C.; Cotton, Daniel M.; Chakrabarti, Supriya

    1992-01-01

    We describe an instrument package to remotely measure thermospheric, exospheric, and plasmaspheric structure and composition. This instrument was flown aboard the second test flight of the Black Brant XII sounding rocket on December 5, 1989, which attained an apogee of 1460 km. The experiment package consisted of a spectrophotometer to measure He I 584 A, O II 834 A, O I 989 A, hydrogen Lyman beta (1025 A), hydrogen Lyman alpha (1216 A), and O I 1304 A transitions, and a photometer to measure the He II 304 A emission. The optical design of the spectrophotometer was identical to that of the Berkeley Extreme Ultraviolet (EUV) Airglow Rocket Spectrometer payload, flown on September 30, 1988 aboard the maiden flight of the Black Brant XII rocket. We present the initial data analysis and describe directions we will go toward the completion of our study.

  12. Telescience at the University of California, Berkeley

    NASA Technical Reports Server (NTRS)

    Chakrabarti, S.; Marchant, W. T.; Kaplan, G. C.; Dobson, C. A.; Jernigan, J. G.; Lampton, M. L.; Malina, R. F.

    1989-01-01

    The University of California at Berkeley (UCB) is a member of a university consortium involved in telescience testbed activities under the sponsorship of NASA. Our Telescience Testbed Project consists of three experiments using flight hardware being developed for the Extreme Ultraviolet Explorer project at UCB's Space Sciences Laboratory. The first one is a teleoperation experiment investigating remote instrument control using a computer network such as the Internet. The second experiment is an effort to develop a system for operation of a network of remote workstations allowing coordinated software development, evaluation, and use by widely dispersed groups. The final experiment concerns simulation as a method to facilitate the concurrent development of instrument hardware and support software. We describe our progress in these areas.

  13. Lawrence Berkeley Laboratory Affirmative Action Program. Revised

    SciTech Connect

    1995-06-01

    The Lawrence Berkeley Laboratory`s Affirmative Action Program (AAP) serves as a working document that describes current policies, practices, and results in the area of affirmative action. It represents the Laboratory`s framework for an affirmative approach to increasing the representation of people of color and women in segments of our work force where they have been underrepresented and taking action to increase the employment of persons with disabilities and special disabled and Vietnam era veterans. The AAP describes the hierarchy of responsibility for Laboratory affirmative action, the mechanisms that exist for full Laboratory participation in the AAP, the policies and procedures governing recruitment at all levels, the Laboratory`s plan for monitoring, reporting, and evaluating affirmative action progress, and a description of special affirmative action programs and plans the Laboratory has used and will use in its efforts to increase the representation and retention of groups historically underrepresented in our work force.

  14. Junior High Schools of Berkeley, California. Bulletin, 1923, No. 4

    ERIC Educational Resources Information Center

    Preston, James T.; Clark, W. B.; Glessner, H. H.; Hennessey, D. L.

    1923-01-01

    This bulletin demonstrates that Berkeley, California's educational problem is and has been that of meeting the varied needs of a population such as may be found in any typical American city. The varied population needs, together with the rapid growth, have brought many difficult problems to Berkeley, just has they have to other cities. Based on…

  15. ECR (Electron Cyclotron Resonance) ion sources for cyclotrons

    SciTech Connect

    Lyneis, C.M.

    1986-10-01

    In the last decade ECR (Electron Cyclotron Resonance) ion sources have evolved from a single large, power consuming, complex prototype into a variety of compact, simple, reliable, efficient, high performance sources of high charge state ions for accelerators and atomic physics. The coupling of ECR sources to cyclotrons has resulted in significant performance gains in energy, intensity, reliability, and variety of ion species. Seven ECR sources are in regular operation with cyclotrons and numerous other projects are under development or in the planning stag. At least four laboratories have ECR sources dedicated for atomic physics research and other atomic physics programs share ECR sources with cyclotrons. An ECR source is now installed on the injector for the CERN SPS synchrotron to accelerate O/sup 8 +/ to relativistic energies. A project is underway at Argonne to couple an ECR source to a superconducting heavy-ion linac. Although tremendous progress has been made, the field of ECR sources is still a relatively young technology and there is still the potential for further advances both in source development and understanding of the plasma physics. The development of ECR sources is reviewed. The important physics mechanisms which come into play in the operation of ECR Sources are discussed, along with various models for charge state distributions (CSD). The design and performance of several ECR sources are compared. The 88-Inch Cyclotron and the LBL ECR is used as an example of cyclotron+ECR operation. The future of ECR sources is considered.

  16. What Made Berkeley Great? The Sources of Berkeley's Sustained Academic Excellence. Research & Occasional Paper Series CSHE.3.11

    ERIC Educational Resources Information Center

    Breslauer, George W.

    2011-01-01

    University of California (UC) Berkeley's chief academic officer explores the historical sources of Berkeley' academic excellence. He identifies five key factors: (1) wealth from many sources; (2) supportive and skilled governors; (3) leadership from key UC presidents; (4) the pioneering ethos within the State of California; and (5) a process of…

  17. EC-5 fifth international workshop on electron cyclotron emission and electron cyclotron heating

    SciTech Connect

    Prater, R.; Lohr, J.

    1985-12-31

    This report contains papers on the following topics: electron cyclotron emission measurements; electron cyclotron emission theory; electron cyclotron heating; gyrotron development; and ECH systems and waveguide development. These paper have been indexed separately elsewhere. (LSP).

  18. BEST medical radioisotope production cyclotrons

    SciTech Connect

    Sabaiduc, Vasile; Milton, Bruce; Suthanthiran, Krishnan; Johnson, Richard R.; Gelbart, W. Z.

    2013-04-19

    Best Cyclotron Systems Inc (BCSI) is currently developing 14 MeV, 25 MeV, 35MeV and 70MeV cyclotrons for radioisotope production and research applications as well as the entire spectrum of targets and nuclear synthesis modules for the production of Positron Emission Tomography (PET), Single Photon Emission Computed Tomography (SPECT) and radiation therapy isotopes. The company is a subsidiary of Best Medical International, renowned in the field of medical instrumentation and radiation therapy. All cyclotrons have external negative hydrogen ion sources, four radial sectors with two dees in opposite valleys, cryogenic vacuum system and simultaneous beam extraction on opposite lines. The beam intensity ranges from 400 {mu}A to 1000 {mu}A, depending on the cyclotron energy and application.

  19. BEST medical radioisotope production cyclotrons

    NASA Astrophysics Data System (ADS)

    Sabaiduc, Vasile; Milton, Bruce; Suthanthiran, Krishnan; Gelbart, W. Z.; Johnson, Richard R.

    2013-04-01

    Best Cyclotron Systems Inc (BCSI) is currently developing 14 MeV, 25 MeV, 35MeV and 70MeV cyclotrons for radioisotope production and research applications as well as the entire spectrum of targets and nuclear synthesis modules for the production of Positron Emission Tomography (PET), Single Photon Emission Computed Tomography (SPECT) and radiation therapy isotopes. The company is a subsidiary of Best Medical International, renowned in the field of medical instrumentation and radiation therapy. All cyclotrons have external negative hydrogen ion sources, four radial sectors with two dees in opposite valleys, cryogenic vacuum system and simultaneous beam extraction on opposite lines. The beam intensity ranges from 400 μA to 1000 μA, depending on the cyclotron energy and application [1].

  20. FEL on slow cyclotron wave

    SciTech Connect

    Silivra, A.

    1995-12-31

    A physical mechanism of interaction of fast electromagnetic wave with slow cyclotron wave of relativistic electron beam in a FEL with helical wiggler field is described. It is shown that: (1) interaction is possible for both group of steady state electron trajectories (2) positive gain is achieved within certain interval of guide field strength (3) operation wavelength for group 1 trajectories ({Omega}{sub 0}/{gamma} < k{omega}{upsilon}{parallel}) is shorter than for the conventional FEL synchronism. A nonlinear analysis shows that efficiency of slow cyclotron FEL is restricted mainly by a breakdown of a single electron synchronism due to dependence of (modified) electron cyclotron frequency on an energy of electron. Nevertheless, as numerical simulation shows, typical efficiency of 15 % order is achieved in millimeter wavelength band for the midrelativistic ({gamma}= 3 {divided_by} 4) slow cyclotron wave FEL. Tapering of magnetic field results in a substantial increase of efficiency.

  1. Cyclotron Production of Medical Radioisotopes

    SciTech Connect

    Avila-Rodriguez, M. A.; Zarate-Morales, A.; Flores-Moreno, A.

    2010-08-04

    The cyclotron production of radioisotopes for medical applications is gaining increased significance in diagnostic molecular imaging techniques such as PET and SPECT. In this regard, radioisotope production has never been easier or more convenient until de introduction of compact medical cyclotrons in the last few decades, which allowed the use of short-lived radioisotopes in in vivo nuclear medicine studies on a routine basis. This review outlines some general considerations about the production of radioisotopes using charged particle accelerators.

  2. The Berkeley SETI Program: SERENDIP III

    NASA Astrophysics Data System (ADS)

    Donnelly, C.; Bowyer, S.; Werthimer, D.; Ng, D.; Cobb, J.

    1993-05-01

    The Berkeley SETI (Search for Extraterrestrial Intelligence) program, named SERENDIP, was begun in the late 1970's. It is aimed at detecting narrow band radio signals from extraterrestrial civilizations. The SERENDIP I, II and III systems have operated autonomously in a piggyback search mode, conducting unobtrusive, long-term observations on the world's largest radio telescopes. The latest generation SERENDIP instrument, SERENDIP III, is a four million channel FFT-based spectrum analyzer operating at 0.6 Hz resolution with a 1.7 second integration time. SERENDIP III has been operating at the NAIC Arecibo Observatory since April, 1992. Several independent criteria suggest that this search is the most sensitive SETI search in operation. To date SERENDIP III has accumulated over 3600 hours of high quality telescope time, observing 75% of the sky visible by the Arecibo telescope. Over this period SERENDIP III has analyzed over 30 trillion spectral bins, and recorded information on 110 million strong narrow band signals in the 424--435 MHz band. A handful of these signals have survived our RFI rejection and signal detection algorithms, and have thus been added to our list of ETI candidate signals. A follow-up observation program will be conducted next year in an attempt to verify each of these candidate signals. This work has been supported by NASA grant NAGW-2722.

  3. Life sciences: Lawrence Berkeley Laboratory, 1988

    SciTech Connect

    Not Available

    1989-07-01

    Life Sciences Research at LBL has both a long history and a new visibility. The physics technologies pioneered in the days of Ernest O. Lawrence found almost immediate application in the medical research conducted by Ernest's brother, John Lawrence. And the tradition of nuclear medicine continues today, largely uninterrupted for more than 50 years. Until recently, though, life sciences research has been a secondary force at the Lawrence Berkeley Laboratory (LBL). Today, a true multi-program laboratory has emerged, in which the life sciences participate as a full partner. The LBL Human Genome Center is a contribution to the growing international effort to map the human genome. Its achievements represent LBL divisions, including Engineering, Materials and Chemical Sciences, and Information and Computing Sciences, along with Cell and Molecular Biology and Chemical Biodynamics. The Advanced Light Source Life Sciences Center will comprise not only beamlines and experimental end stations, but also supporting laboratories and office space for scientists from across the US. This effort reflects a confluence of scientific disciplines --- this time represented by individuals from the life sciences divisions and by engineers and physicists associated with the Advanced Light Source project. And finally, this report itself, the first summarizing the efforts of all four life sciences divisions, suggests a new spirit of cooperation. 30 figs.

  4. ORFEUS focal plane instrumentation: The Berkeley spectrometer

    NASA Technical Reports Server (NTRS)

    Hurwitz, Mark; Bowyer, Stuart

    1988-01-01

    A spectrograph for the ORFEUS mission that incorporates four varied line-space, spherically figured diffraction gratings was designed. The ORFEUS, a 1-m normal incidence telescope is equipped with 2 focal plane spectrographs. The Berkeley spectrograph was developed with an optimizing raytracing computer code. Each grating accepts the light from 20 percent of the aperture of the telescope primary mirror and has a unique set of characteristics to cover a sub-bandpass within the 390 to 1200 A spectral range. Two photon-counting detectors incorporating a time delay readout system are used to record the spectra from all four gratings simultaneously. The nominal design achieves a spectral resolution (FWHM) in excess of 5500 at all wavelengths within the bandpass. The resolution is limited primarily by the detector spatial resolution. The 1 sigma astigmatism of this design varies between 13 and 150 micrometer on the same focal surface. An independent, direct imaging system tracks the drift of the target within the spectrometer aperture and allows measurement of the misalignment between the telescope optical axis and that of the external star tracker. The resolution and astigmatism achievable with this design are superior to those of a standard Rowland spectrograph designed with the same constraints.

  5. Molecular Foundry Workshop draws overflow crowd to BerkeleyLab

    SciTech Connect

    Robinson, Art

    2002-11-27

    Nanoscale science and technology is now one of the top research priorities in the United States. With this background, it is no surprise that an overflow crowd or more than 350 registrants filled two auditoriums to hear about and contribute ideas for the new Molecular Foundry during a two-day workshop at the Lawrence Berkeley National Laboratory (Berkeley Lab). Scheduled to open for business at Berkeley Labin early 2006, the Molecular Foundry is one of three Nanoscale Science Research Centers (NSRCs) put forward for funding by the DOE's Office of Basic Energy Sciences (BES).

  6. Multimegawatt cyclotron autoresonance accelerator

    SciTech Connect

    Hirshfield, J.L.; LaPointe, M.A.; Ganguly, A.K.; Yoder, R.B.; Wang, C.

    1996-05-01

    Means are discussed for generation of high-quality multimegawatt gyrating electron beams using rf gyroresonant acceleration. TE{sub 111}-mode cylindrical cavities in a uniform axial magnetic field have been employed for beam acceleration since 1968; such beams have more recently been employed for generation of radiation at harmonics of the gyration frequency. Use of a TE{sub 11}-mode waveguide for acceleration, rather than a cavity, is discussed. It is shown that the applied magnetic field and group velocity axial tapers allow resonance to be maintained along a waveguide, but that this is impractical in a cavity. In consequence, a waveguide cyclotron autoresonance accelerator (CARA) can operate with near-100{percent} efficiency in power transfer from rf source to beam, while cavity accelerators will, in practice, have efficiency values limited to about 40{percent}. CARA experiments are described in which an injected beam of up to 25 A, 95 kV has had up to 7.2 MW of rf power added, with efficiencies of up to 96{percent}. Such levels of efficiency are higher than observed previously in any fast-wave interaction, and are competitive with efficiency values in industrial linear accelerators. Scaling arguments suggest that good quality gyrating megavolt beams with peak and average powers of 100 MW and 100 kW can be produced using an advanced CARA, with applications in the generation of high-power microwaves and for possible remediation of flue gas pollutants. {copyright} {ital 1996 American Institute of Physics.}

  7. Berkeley Lab: A Place of Wonder, Spring 2006

    SciTech Connect

    2008-01-01

    Video produced in early 2006. Lawrence Berkeley National Lab has been a leader in science and engineering research for more than 75 years. The Lab conducts a wide range of scientific research with key efforts in fundamental studies of the universe, quantitative biology, nanoscience, new energy systems and environmental solutions, and the use of computing as a tool for discovery. Located on a 200 acre site in the hills above the University of California's Berkeley campus, adjacent to the San Francisco Bay, Berkeley Lab holds the distinction of being the oldest of the U.S. Department of Energy's National Laboratories. Eleven Nobel laureates are associated with Berkeley Lab. It is managed by the University of California.

  8. Former Fermilab boss to lead Lawrence Berkeley National Laboratory

    NASA Astrophysics Data System (ADS)

    Gwynne, Peter

    2016-03-01

    Particle physicist Michael Witherell - current vice-chancellor for research at the University of California, Santa Barbara (UCSB) - has been appointed the next director of the Lawrence Berkeley National Laboratory (LBL).

  9. Annual environmental monitoring report of the Lawrence Berkeley Laboratory, 1980

    SciTech Connect

    Schleimer, G.E.

    1981-04-01

    The Environmental Monitoring Program of the Lawrence Berkeley Laboratory is described. Data on air and water sampling and continuous radiation monitoring for 1980 are presented, and general trends are discussed.

  10. Cyclotron resonance in graphene

    NASA Astrophysics Data System (ADS)

    Henriksen, Erik Alfred

    We present a study of cyclotron resonance in graphene. Graphene is a novel two-dimensional system consisting of a single sheet of atoms arranged in a honeycomb lattice, and exhibits a unique, linear low-energy dispersion. Bilayer graphene, two sheets stacked together, is an equally interesting system displaying a second unique, but hyperbolic, dispersion. In this work, we study the quantized Landau levels of these systems in strong magnetic fields, via Fourier-transform infrared spectroscopy. We have fabricated large area single layer and bilayer graphene devices on infrared-transparent Si/SiO2 substrates, using standard electron beam lithography and thin-film liftoff techniques. At cryogenic temperatures and high magnetic fields, we measure the infrared transmission through these devices as a function of the back gate voltage, which changes the Fermi level and hence the carrier density. We analyze the normalized transmission traces, assigning the observed minima to the cyclotron resonance wherein carriers are excited between Landau levels. In single layer graphene, we study Landau level transitions near the charge neutral Dirac point, and find a set of particle-hole symmetric transitions, both within the conduction and valence band, and between the bands. These experiments confirm the unusual B- and n -dependencies of the LL energies, where B is the magnetic field and n the LL index. The CR selection rule is determined to be Delta n = |nfinal| -- |n initial| = +/-1. The ratio of the observed interband and intraband transitions exceeds the expected value by 5%, and this excess is interpreted as an additional contribution to the transition energy from many-particle effects. We explore several higher LL transitions for both electron and hole doping of single layer graphene. The data are consistent with a renormalization of the carrier band velocity near the Dirac point, and suggest that impurity scattering strengthens at low energies. We also study the CR at the

  11. Annual environmental monitoring report of the Lawrence Berkeley Laboratory

    SciTech Connect

    Schleimer, G.E.; Pauer, R.O.

    1990-08-01

    The Lawrence Berkeley Laboratory (LBL) is a multiprogram national laboratory managed by the University of California (UC) for the US Department of Energy (DOE). LBL's major role is to conduct basic and applied science research that is appropriate for an energy research laboratory. The Environmental Monitoring Program of the Lawrence Berkeley Laboratory is described. Data for 1989 are presented, and general trends are discussed. 17 refs., 12 figs., 23 tabs.

  12. Theory of relativistic cyclotron masers

    NASA Astrophysics Data System (ADS)

    Nusinovich, G. S.; Latham, P. E.; Dumbrajs, O.

    1995-07-01

    In this paper we have made an attempt to review the present status of the theory of cyclotron masers with relativistic electron beams. After discussing the basic features of electron-cyclotron radiation under conditions of normal and anomalous Doppler frequency shifts, we consider particle deceleration by a constant amplitude electromagnetic wave in a constant magnetic field using the formalism developed earlier for cyclotron autoresonance acceleration of electrons. An optimal cyclotron resonance mismatch was found that corresponds to the possibility of complete deceleration of relativistic electrons. Then, interaction of relativistic electrons with resonator fields is considered and the efficiency increase due to electron prebunching is demonstrated in a simple model. Since an efficient interaction of relativistic electrons with the large amplitude electromagnetic field of a resonator occurs at a short distance, where electrons make a small number of electron orbits, the issue of the simultaneous interaction of electrons with the field at several cyclotron harmonics is discussed. Finally, we consider deceleration of a prebunched electron beam by a traveling electromagnetic wave in a tapered magnetic field. This simple modeling is illustrated with a number of simulations of relativistic gyroklystrons and gyrotwistrons (gyrodevices in which the bunching cavity of the gyroklystron is combined with the output waveguide of the gyro-traveling-wave-tube).

  13. Use of cyclotrons in medicine

    NASA Astrophysics Data System (ADS)

    Qaim, S. M.

    2004-10-01

    Cyclotrons are versatile ion-accelerating machines which find many applications in medicine. In this short review their use in hadron therapy is briefly discussed. Proton therapy is gaining significance because of its capability to treat deep-lying tumours. A strong area of application of cyclotrons involves the production of short-lived neutron deficient radiotracers for use in emission tomography, especially positron emission tomography. This fast and quantitative in vivo diagnostic technique is being increasingly used in neurology, cardiology and oncology. Besides routine patient care, considerable interdisciplinary work on development of new positron emitters is under way. A short account of those efforts is given. The use of cyclotrons in the production of radionuclides for internal radiotherapy is also briefly described.

  14. Electron cyclotron harmonic wave acceleration

    NASA Technical Reports Server (NTRS)

    Karimabadi, H.; Menyuk, C. R.; Sprangle, P.; Vlahos, L.

    1987-01-01

    A nonlinear analysis of particle acceleration in a finite bandwidth, obliquely propagating electromagnetic cyclotron wave is presented. It has been suggested by Sprangle and Vlahos in 1983 that the narrow bandwidth cyclotron radiation emitted by the unstable electron distribution inside a flaring solar loop can accelerate electrons outside the loop by the interaction of a monochromatic wave propagating along the ambient magnetic field with the ambient electrons. It is shown here that electrons gyrating and streaming along a uniform, static magnetic field can be accelerated by interacting with the fundamental or second harmonic of a monochromatic, obliquely propagating cyclotron wave. It is also shown that the acceleration is virtually unchanged when a wave with finite bandwidth is considered. This acceleration mechanism can explain the observed high-energy electrons in type III bursts.

  15. Cyclotron radiation in hot magnetoplasmas.

    NASA Technical Reports Server (NTRS)

    Trulsen, J.

    1971-01-01

    The effects of thermal motions on the cyclotron radiation from test particles gyrating in a homogeneous magnetoplasma are studied. These effects take care of all singularities that exist in the theory of cyclotron radiation in cold magnetoplasma - e.g., the divergence in energy loss for small particle energies. Around the hybrid frequencies thermal corrections become of dominant importance. At these frequencies cold-plasma theory breaks down. Thermal effects arise in two ways: by modifying the wave modes known from cold plasma theory, and by the introduction of a new longitudinal wave mode, known as the Bernstein mode. All wave modes are damped (in stable plasmas).

  16. Cyclotron Resonance in Accreting Pulsars

    NASA Astrophysics Data System (ADS)

    Bhattacharya, Dipankar

    2016-07-01

    Cyclotron Resonance Absorption/Scattering features provide direct measurement of magnetic field strength in the line forming region. This has enabled the estimation of magnetic field strengths of nearly two dozen neutron stars in accreting high mass binary systems. With improved spectroscopic sensitivity, new X-ray observatories such as NuSTAR, Astrosat and Hitomi are opening the doors to studying detailed features such as the line shape and phase dependence with high significance. Such studies will help understand the nature of matter accumulation in, and outflow from, the magnetically confined accretion column on the neutron star. This talk will describe the results of MHD simulations of the matter flow in such systems, the diagnostics of such flows using cyclotron lines, and comparison with recent observations from NuSTAR and Astrosat.

  17. A Survey of Summer Quarter Students at Berkeley, 1968.

    ERIC Educational Resources Information Center

    Suslow, Sidney; Pieper, W. C., Jr.

    When the University of California at Berkeley initiated year-round operation in the summer of 1967, the prevailing question concerned whether such a system would work. Midway through the summer term of the following year, a mail survey of 2,100 students --a 25% sample of those enrolled in the 1968 Summer Quarter-- was conducted to evaluate the…

  18. Integration Defended: Berkeley Unified's Strategy to Maintain School Diversity

    ERIC Educational Resources Information Center

    Chavez, Lisa; Frankenberg, Erica

    2009-01-01

    In June 2007, the Supreme Court limited the tools that school districts could use to voluntarily integrate schools. In the aftermath of the decision, educators around the country have sought models of successful plans that would also be legal. One such model may be Berkeley Unified School District's (BUSD) plan. Earlier this year, the California…

  19. Asian Americans at Berkeley. A Report to the Chancellor.

    ERIC Educational Resources Information Center

    California Univ., Berkeley.

    An advisory committee appointed in fall, 1987 was charged with carrying out an indepth study of Asian Americans on the campus of the University of California at Berkeley. Questions addressed concerned student educational experiences, faculty recruitment and advancement, and staff employment opportunities as well as questions about campus-Asian…

  20. Berkeley Lab Scientist Co-Leads Breast Cancer Dream Team

    ScienceCinema

    Gray, Joe

    2013-05-29

    An $16.5 million, three-year grant to develop new and more effective therapies to fight breast cancer was awarded today to a multi-institutional Dream Team of scientists and clinicians that is co-led by Joe Gray, a renowned cancer researcher with the U.S. Department of Energys Lawrence Berkeley National Laboratory. http://newscenter.lbl.gov/

  1. Pass-Fail Grading at Berkeley: Facts and Opinions.

    ERIC Educational Resources Information Center

    Suslow, Sidney

    The facts and opinions regarding pass/no pass grading at Berkeley discussed in this report are based on three sources of information. These sources include a survey of faculty conducted in the spring quarter 1970, a survey of undergraduate students in the winter quarter 1971, and the records routinely generated in the Registrar's Office for the…

  2. Behind the Scenes at Berkeley Lab - The Mechanical Fabrication Facility

    ScienceCinema

    Wells, Russell; Chavez, Pete; Davis, Curtis; Bentley, Brian

    2014-09-15

    Part of the Behind the Scenes series at Berkeley Lab, this video highlights the lab's mechanical fabrication facility and its exceptional ability to produce unique tools essential to the lab's scientific mission. Through a combination of skilled craftsmanship and precision equipment, machinists and engineers work with scientists to create exactly what's needed - whether it's measured in microns or meters.

  3. Behind the Scenes at Berkeley Lab - The Mechanical Fabrication Facility

    SciTech Connect

    Wells, Russell; Chavez, Pete; Davis, Curtis; Bentley, Brian

    2013-05-17

    Part of the Behind the Scenes series at Berkeley Lab, this video highlights the lab's mechanical fabrication facility and its exceptional ability to produce unique tools essential to the lab's scientific mission. Through a combination of skilled craftsmanship and precision equipment, machinists and engineers work with scientists to create exactly what's needed - whether it's measured in microns or meters.

  4. For Berkeley's Sports Endowment, a Goal of $1-Billion

    ERIC Educational Resources Information Center

    Keller, Josh

    2009-01-01

    Most athletics programs, if forced to raise $300-million to renovate a football stadium, would not set an ambitious endowment goal at the same time. The University of California at Berkeley is trying to do both. The university's California Memorial Stadium sits directly over an earthquake fault: it needs a major seismic retrofit that will take…

  5. Berkeley extreme-ultraviolet airglow rocket spectrometer - BEARS

    NASA Technical Reports Server (NTRS)

    Cotton, D. M.; Chakrabarti, S.

    1992-01-01

    The Berkeley EUV airglow rocket spectrometer (BEARS) instrument is described. The instrument was designed in particular to measure the dominant lines of atomic oxygen in the FUV and EUV dayglow at 1356, 1304, 1027, and 989 A, which is the ultimate source of airglow emissions. The optical and mechanical design of the instrument, the detector, electronics, calibration, flight operations, and results are examined.

  6. Teaching at Berkeley: A Guide for Foreign Teaching Assistants.

    ERIC Educational Resources Information Center

    Cohen, Robby, Ed.; Robin, Ron, Ed.

    A handbook for foreign teaching assistants (TAs) is presented by foreign graduate students with teaching experience and other educators who have worked closely with them. Language skills, teaching strategies, cultural issues, resources, and the environment at the University of California, Berkeley, are addressed in 16 articles. Article titles and…

  7. Lawrence Berkeley Laboratory Institutional Plan FY 1995--2000

    SciTech Connect

    1994-12-01

    This report presents the details of the mission and strategic plan for Lawrence Berkeley Laboratory during the fiscal years of 1995--2000. It presents summaries of current programs and potential changes; critical success factors such as human resources; management practices; budgetary allowances; and technical and administrative initiatives.

  8. Annual environmental monitoring report of the Lawrence Berkeley Laboratory, 1986

    SciTech Connect

    Schleimer, G.E.

    1987-04-01

    The Environmental Monitoring Program of the Lawrence Berkeley Laboratory is described. Data for 1986 are presented and general trends are discussed. Topics include radiation monitoring, wastewater discharge monitoring, dose distribution estimates, and ground water monitoring. 9 refs., 8 figs., 20 tabs.

  9. Commercial compact cyclotrons in the 90`s

    SciTech Connect

    Milton, B.F.

    1995-09-01

    Cyclotrons continue to be efficient accelerators for radio-isotope production. In recent years, developments in the accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicate a strong future for commercial cyclotrons. In this paper the authors will survey recent developments in the areas of cyclotron technology, as they relate to the new generation of commercial cyclotrons. Design criteria for the different types of commercial cyclotrons will be presented, with reference to those demands that differ from those in a research oriented cyclotron project. The authors also discuss the possibility of systems designed for higher energies and capable of extracted beam currents of up to 2.0 mA.

  10. Method and apparatus for ion cyclotron spectrometry

    DOEpatents

    Dahl, David A [Idaho Falls, ID; Scott, Jill R [Idaho Falls, ID; McJunkin, Timothy R [Idaho Falls, ID

    2010-08-17

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber that includes at least a first section that induces a first magnetron effect that increases a cyclotron frequency of an ion and at least a second section that induces a second magnetron effect that decreases the cyclotron frequency of an ion. The cyclotron frequency changes induced by the first and second magnetron effects substantially cancel one another so that an ion traversing the at least first and second sections will experience no net change in cyclotron frequency.

  11. Breakdown of cyclotron resonance in semiconductor superlattices

    NASA Astrophysics Data System (ADS)

    Duffield, T.; Bhat, R.; Koza, M.; Hwang, D. M.; DeRosa, F.; Grabbe, P.; Allen, S. J.

    1988-03-01

    We have observed breakdown of cyclotron resonance in large magnetic fields oriented perpendicular to the growth direction in semiconductor superlattices. At small magnetic fields conventional cyclotron resonance is observed with the mass related to the miniband mass. At large magnetic fields, when the cyclotron diameter approaches the superlattice period, the resonance frequency appears to saturate and is determined by orbits impaled on the barrier. A model calculation gives good account of the magnetic field dependence of the resonance position and line width.

  12. Hydrogeology and tritium transport in Chicken Creek Canyon,Lawrence Berkeley National Laboratory, Berkeley, California

    SciTech Connect

    Jordan, Preston D.; Javandel, Iraj

    2007-10-31

    This study of the hydrogeology of Chicken Creek Canyon wasconducted by the Environmental Restoration Program (ERP) at LawrenceBerkeley National Laboratory (LBNL). This canyon extends downhill fromBuilding 31 at LBNL to Centennial Road below. The leading edge of agroundwater tritium plume at LBNL is located at the top of the canyon.Tritium activities measured in this portion of the plume during thisstudy were approximately 3,000 picocuries/liter (pCi/L), which issignificantly less than the maximum contaminant level (MCL) for drinkingwaterof 20,000 pCi/L established by the Environmental ProtectionAgency.There are three main pathways for tritium migration beyond theLaboratory s boundary: air, surface water and groundwater flow. Thepurpose of this report is to evaluate the groundwater pathway.Hydrogeologic investigation commenced with review of historicalgeotechnical reports including 35 bore logs and 27 test pit/trench logsas well as existing ERP information from 9 bore logs. This was followedby field mapping of bedrock outcrops along Chicken Creek as well asbedrock exposures in road cuts on the north and east walls of the canyon.Water levels and tritium activities from 6 wells were also considered.Electrical-resistivity profiles and cone penetration test (CPT) data werecollected to investigate the extent of an interpreted alluvial sandencountered in one of the wells drilled in this area. Subsequent loggingof 7 additional borings indicated that this sand was actually anunusually well-sorted and typically deeply weathered sandstone of theOrinda Formation. Wells were installed in 6 of the new borings to allowwater level measurement and analysis of groundwater tritium activity. Aslug test and pumping tests were also performed in the wellfield.

  13. Nuclear Medicine at Berkeley Lab: From Pioneering Beginnings to Today (LBNL Summer Lecture Series)

    ScienceCinema

    Budinger, Thomas [LBNL, Center for Functional Imaging

    2011-10-04

    Summer Lecture Series 2006: Thomas Budinger, head of Berkeley Lab's Center for Functional Imaging, discusses Berkeley Lab's rich history pioneering the field of nuclear medicine, from radioisotopes to medical imaging.

  14. The Undergraduate Origins of PhD Economists: The Berkeley Experience

    ERIC Educational Resources Information Center

    Olney, Martha L.

    2015-01-01

    The University of California, Berkeley sends more undergraduate students to economics PhD programs than any other public university. While this fact is surely a function of its size, there may be lessons from the Berkeley experience that others could adopt. To investigate why Berkeley generates so many economics PhD students, the author convened…

  15. Sneak Preview of Berkeley Lab's Science at the Theatre on June 6th, 2011

    ScienceCinema

    Sanii, Babak

    2013-05-29

    Babak Sanii provides a sneak preview of Berkeley Lab's next Science at the Theater Event: Big Thinking: The Power of Nanoscience. Berkeley Lab scientists reveal how nanoscience will bring us cleaner energy, faster computers, and improved medicine. Berkeley Repertory Theatre on June 6th, 2011

  16. Sneak Preview of Berkeley Lab's Science at the Theatre on June 6th, 2011

    SciTech Connect

    Sanii, Babak

    2011-01-01

    Babak Sanii provides a sneak preview of Berkeley Lab's next Science at the Theater Event: Big Thinking: The Power of Nanoscience. Berkeley Lab scientists reveal how nanoscience will bring us cleaner energy, faster computers, and improved medicine. Berkeley Repertory Theatre on June 6th, 2011

  17. Cyclotron Line Measurements with INTEGRAL

    NASA Technical Reports Server (NTRS)

    Pottschmidt, K.; Kreykenbohm, I.; Caballero, I.; Fritz, S.; Schoenherr, G.; Kretschmar, P.; Wilms, J.; McBride, V. A.; Suchy, S.; Rothschild, R. E.

    2008-01-01

    Due to its broadband energy coverage, INTEGRAL has made important contributions to observing and interpreting cyclotron lines, which are present in the 10-100 keV range of a sample of accreting pulsars. In these systems photons with energies fulfilling the resonance condition inelastically Compton scatter off electrons quantized in the accretion column above the neutron star's magnetic pole(s). This process gives rise to the broad, absorption-like lines or 'cyclotron resonant scattering features' (CRSF). The observed lines allow to directly measure the B-fields of these sources, resulting in values of a few times 1E12G. In this overview I will present recent highlights regarding CRSF observations as well as discuss current ideas and models for the physical conditions in the accretion column. Among the former are the stability of the spectrum of Vela X-1 during giant flares in 2003, the observation of three cyclotron lines during the 2004 outburst of V0332+53, the confirmation of the fundamental line at approximately 45 keV during a 2005 normal outburst of A0535-26, and the simultaneous detection of the two lines in the dipping source 4U 1907+09 (for which also a torque reversal was detected for the first time). Through these and other observations it has become increasingly apparent that two types of observations can potentially be used to constrain the accretion column geometry: the determination of energy ratios for multiple harmonic lines (only two sources with greater than 2 lines are known), was well as the evolution of the fundamental line centroid, which, for different sources, may or may not be correlated with flux. Furthermore, first steps have been taken away from the usual phenomenological description of the lines, towards a physical approach based on self-consistent CRSF modeling. Initial applications are presented.

  18. Ion cyclotron waves at Titan

    NASA Astrophysics Data System (ADS)

    Russell, C. T.; Wei, H. Y.; Cowee, M. M.; Neubauer, F. M.; Dougherty, M. K.

    2016-03-01

    During the interaction of Titan's thick atmosphere with the ambient plasma, it was expected that ion cyclotron waves would be generated by the free energy of the highly anisotropic velocity distribution of the freshly ionized atmospheric particles created in the interaction. However, ion cyclotron waves are rarely observed near Titan, due to the long growth times of waves associated with the major ion species from Titan's ionosphere, such as CH4+ and N2+. In the over 100 Titan flybys obtained by Cassini to date, there are only two wave events, for just a few minutes during T63 flyby and for tens of minutes during T98 flyby. These waves occur near the gyrofrequencies of proton and singly ionized molecular hydrogen. They are left-handed, elliptically polarized, and propagate nearly parallel to the field lines. Hybrid simulations are performed to understand the wave growth under various conditions in the Titan environment. The simulations using the plasma and field conditions during T63 show that pickup protons with densities ranging from 0.01 cm-3 to 0.02 cm-3 and singly ionized molecular hydrogens with densities ranging from 0.015 cm-3 to 0.25 cm-3 can drive ion cyclotron waves with amplitudes of ~0.02 nT and of ~0.04 nT within appropriate growth times at Titan, respectively. Since the T98 waves were seen farther upstream than the T63 waves, it is possible that the instability was stronger and grew faster on T98 than T63.

  19. Cyclotrons for the production of radioactive beams

    SciTech Connect

    Clark, D.J.

    1990-01-01

    This paper describes the characteristics and design choices for modern cyclotrons. Cyclotrons can be used in 3 areas in the radioactive beam field: the production of high energy heavy ion beams for use in fragmentation, the spallation of targets with high energy protons, and the acceleration of radioactive beams from low energy to the MeV/u range. 16 refs., 6 figs.

  20. Overview of Light-Ion Beam Therapy

    SciTech Connect

    Chu, William T.

    2006-03-16

    In 1930, Ernest Orlando Lawrence at the University of California at Berkeley invented the cyclotron. One of his students, M. Stanley Livingston, constructed a 13-cm diameter model that had all the features of early cyclotrons, accelerating protons to 80 keV using less than 1 kV on a semi-circular accelerating electrode, now called the ''dee''. Soon after, Lawrence constructed the first two-dee 27-Inch (69-cm) Cyclotron, which produced protons and deuterons of 4.8 MeV. In 1939, Lawrence constructed the 60-Inch (150-cm) Cyclotron, which accelerated deuterons to 19 MeV. Just before WWII, Lawrence designed a 184-inch cyclotron, but the war prevented the building of this machine. Immediately after the war ended, the Veksler-McMillan principle of phase stability was put forward, which enabled the transformation of conventional cyclotrons to successful synchrocyclotrons. When completed, the 184-Inch Synchrocyclotron produced 340-MeV protons. Following it, more modern synchrocyclotrons were built around the globe, and the synchrocyclotrons in Berkeley and Uppsala, together with the Harvard cyclotron, would perform pioneering work in treatment of human cancer using accelerated hadrons (protons and light ions). When the 184-Inch Synchrocyclotron was built, Lawrence asked Robert Wilson, one of his former graduate students, to look into the shielding requirements for of the new accelerator. Wilson soon realized that the 184-Inch would produce a copious number of protons and other light ions that had enough energy to penetrate human body, and could be used for treatment of deep-seated diseases. Realizing the advantages of delivering a larger dose in the Bragg peak when placed inside deep-seated tumors, he published in a medical journal a seminal paper on the rationale to use accelerated protons and light ions for treatment of human cancer. The precise dose localization provided by protons and light ions means lower doses to normal tissues adjacent to the treatment volume

  1. Calibration of the Berkeley EUV Airglow Rocket Spectrometer

    NASA Technical Reports Server (NTRS)

    Cotton, Daniel M.; Chakrabarti, Supriya; Siegmund, Oswald

    1989-01-01

    The Berkeley Extreme-ultraviolet Airglow Rocket Spectrometer (BEARS), a multiinstrument sounding rocket payload, made comprehensive measurements of the earth's dayglow. The primary instruments consisted of two near-normal Rowland mount spectrometers: one channel to measure several atomic oxygen features at high spectral resolution (about 1.5 A) in the band passes 980-1040 and 1300-1360 A, and the other to measure EUV dayglow and the solar EUV simultaneously in a much broader bandpass (250-1150 A) at moderate resolution (about 10 A). The payload also included a hydrogen Lyman-alpha photometer to monitor the solar irradiance and goecoronal emissions. The instrument was calibrated at the EUV calibration facility at the University of California at Berkeley, and was subsequently launched successfully on September 30, 1988 aboard a four-stage experimental sounding rocket, Black Brant XII flight 12.041 WT. The calibration procedure and resulting data are presented.

  2. Better Batteries for Transportation: Behind the Scenes @ Berkeley Lab

    SciTech Connect

    Battaglia, Vince

    2011-01-01

    Vince Battaglia leads a behind-the-scenes tour of Berkeley Lab's BATT, the Batteries for Advanced Transportation Technologies Program he leads, where researchers aim to improve batteries upon which the range, efficiency, and power of tomorrow's electric cars will depend. This is the first in a forthcoming series of videos taking viewers into the laboratories and research facilities that members of the public rarely get to see.

  3. Berkeley Lab scientists develop criteria for $20 million energy challenge

    ScienceCinema

    Walker, Iain

    2013-05-29

    Berkeley Labs Iain Walker and his colleagues in environmental energy research helped the Siebel Foundation develop the criteria for its Energy Free Home Challenge, which comes with a $20 million global incentive prize. The Challenge is a competition to create a new generation of systems and technologies for practical homes that realize a net-zero, non-renewable energy footprint without increasing the cost of ownership. It is open to everyone everywhere ? university teams to handymen and hobbyists.

  4. Berkeley Lab Answers Your Home Energy Efficiency Questions

    ScienceCinema

    Walker, Iain

    2013-11-14

    In this follow-up "Ask Berkeley Lab" video, energy efficiency expert Iain Walker answers some of your questions about home energy efficiency. How do you monitor which appliances use the most energy? Should you replace your old windows? Are photovoltaic systems worth the cost? What to do about a leaky house? And what's the single biggest energy user in your home? Watch the video to get the answers to these and more questions.

  5. The design and implementation of Berkeley Lab's linuxcheckpoint/restart

    SciTech Connect

    Duell, Jason

    2005-04-30

    This paper describes Berkeley Linux Checkpoint/Restart (BLCR), a linux kernel module that allows system-level checkpoints on a variety of Linux systems. BLCR can be used either as a stand alone system for checkpointing applications on a single machine, or as a component by a scheduling system or parallel communication library for checkpointing and restoring parallel jobs running on multiple machines. Integration with Message Passing Interface (MPI) and other parallel systems is described.

  6. Better Batteries for Transportation: Behind the Scenes @ Berkeley Lab

    ScienceCinema

    Battaglia, Vince

    2013-05-29

    Vince Battaglia leads a behind-the-scenes tour of Berkeley Lab's BATT, the Batteries for Advanced Transportation Technologies Program he leads, where researchers aim to improve batteries upon which the range, efficiency, and power of tomorrow's electric cars will depend. This is the first in a forthcoming series of videos taking viewers into the laboratories and research facilities that members of the public rarely get to see.

  7. Berkeley Lab Answers Your Home Energy Efficiency Questions

    SciTech Connect

    Walker, Iain

    2013-02-14

    In this follow-up "Ask Berkeley Lab" video, energy efficiency expert Iain Walker answers some of your questions about home energy efficiency. How do you monitor which appliances use the most energy? Should you replace your old windows? Are photovoltaic systems worth the cost? What to do about a leaky house? And what's the single biggest energy user in your home? Watch the video to get the answers to these and more questions.

  8. Annual site environmental report of the Lawrence Berkeley Laboratory

    SciTech Connect

    Schleimer, G.E.; Pauer, R.O.

    1991-05-01

    The Environmental Monitoring Program of the Lawrence Berkeley Laboratory is described. Data for 1990 are presented, and general trends are discussed. The report is organized under the following topics: Environmental Program Overview; Environmental Permits; Environmental Assessments; Environmental Activities; Penetrating Radiation; Airborne Radionuclides; Waterborne Radionuclides; Public Doses Resulting from LBL Operations; Trends -- LBL Environmental Impact; Waterborne Pollutants; Airborne Pollutants; Groundwater Protection; and Quality Assurance. 20 refs., 26 figs., 23 tabs.

  9. Berkeley Lab Sheds Light on Improving Solar Cell Efficiency

    SciTech Connect

    Lawrence Berkeley National Laboratory

    2007-07-20

    Typical manufacturing methods produce solar cells with an efficiency of 12-15%; and 14% efficiency is the bare minimum for achieving a profit. In work performed at the Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley, CA, 5 10-486-577 1)--a US Department of Energy national laboratory that conducts unclassified scientific research and is managed by the University of California--scientist Scott McHugo has obtained keen insights into the impaired performance of solar cells manufactured from polycrystalline silicon. The solar cell market is potentially vast, according to Berkeley Lab. Lightweight solar panels are highly beneficial for providing electrical power to remote locations in developing nations, since there is no need to build transmission lines or truck-in generator fuel. Moreover, industrial nations confronted with diminishing resources have active programs aimed at producing improved, less expensive solar cells. 'In a solar cell, there is a junction between p-type silicon and an n-type layer, such as diffused-in phosphorous', explained McHugo, who is now with Berkeley Lab's Accelerator and Fusion Research Division. 'When sunlight is absorbed, it frees electrons, which start migrating in a random-walk fashion toward that junction. If the electrons make it to the junction; they contribute to the cell's output of electric current. Often, however, before they reach the junction, they recombine at specific sites in the crystal' (and, therefore, cannot contribute to current output). McHugo scrutinized a map of a silicon wafer in which sites of high recombination appeared as dark regions. Previously, researchers had shown that such phenomena occurred not primarily at grain boundaries in the polycrystalline material, as might be expected, but more often at dislocations in the crystal. However, the dislocations themselves were not the problem. Using a unique heat treatment technique, McHugo performed electrical measurements to investigate the material

  10. Catalog of research projects at Lawrence Berkeley Laboratory, 1985

    SciTech Connect

    Not Available

    1985-01-01

    This Catalog has been created to aid in the transfer of technology from the Lawrence Berkeley Laboratory to potential users in industry, government, universities, and the public. The projects are listed for the following LBL groups: Accelerator and Fusion Research Division, Applied Science Division, Biology and Medicine Division, Center for Advanced Materials, Chemical Biodynamics Division, Computing Division, Earth Sciences Division, Engineering and Technical Services Division, Materials and Molecular Research Division, Nuclear Science Division, and Physics Division.

  11. The cyclotron development activities at CIAE

    NASA Astrophysics Data System (ADS)

    Zhang, Tianjue; Li, Zhenguo; An, Shizhong; Yin, Zhiguo; Yang, Jianjun; Yang, Fang

    2011-12-01

    The cyclotron has an obvious advantage in offering high average current and beam power. Cyclotron development for various applications, e.g. radioactive ion-beam (RIB) generation, clean nuclear energy systems, medical diagnostics and isotope production, were performed at China Institute of Atomic Energy (CIAE) for over 50 years. At the moment two cyclotrons are being built at CIAE, the 100 MeV, CYCIAE-100, and a 14 MeV, the CYCIAE-14. Meanwhile, we are designing and proposing to build a number of cyclotrons with different energies, among them are the CYCIAE-70, the CYCIAE-800, and the upgrading of CYCIAE-CRM, which is going to increase its beam current to mA level. The contribution will present an overall introduction to the cyclotron development activities conducted at CIAE, with different emphasis to each project in order to demonstrate the design and construction highlights.

  12. K-130 Cyclotron vacuum system

    NASA Astrophysics Data System (ADS)

    Yadav, R. C.; Bhattacharya, S.; Bhole, R. B.; Roy, Anindya; Pal, Sarbajit; Mallik, C.; Bhandari, R. K.

    2012-11-01

    The vacuum system for K-130 cyclotron has been operational since 1977. It consists of two sub-systems, main vacuum system and beam line vacuum system. The main vacuum system is designed to achieve and maintain vacuum of about 1 × 10-6 mbar inside the 23 m3 volume of acceleration chamber comprising the Resonator tank and the Dee tank. The beam line vacuum system is required for transporting the extracted beam with minimum loss. These vacuum systems consist of diffusion pumps backed by mechanical pumps like roots and rotary pumps. The large vacuum pumps and valves of the cyclotron vacuum system were operational for more than twenty five years. In recent times, problems of frequent failures and maintenance were occurring due to aging and lack of appropriate spares. Hence, modernisation of the vacuum systems was taken up in order to ensure a stable high voltage for radio frequency system and the extraction system. This is required for efficient acceleration and transportation of high intensity ion beam. The vacuum systems have been upgraded by replacing several pumps, valves, gauges and freon units. The relay based control system for main vacuum system has also been replaced by PLC based state of the art control system. The upgraded control system enables inclusion of additional operational logics and safety interlocks into the system. The paper presents the details of the vacuum system and describes the modifications carried out for improving the performance and reliability of the vacuum system.

  13. Cyclotrons: From Science to Human Health

    NASA Astrophysics Data System (ADS)

    Craddock, Michael

    2011-04-01

    Lawrence's invention of the cyclotron, whose 80th anniversary we have just celebrated, not only revolutionized nuclear physics, but proved the starting point for a whole variety of recirculating accelerators, from the smallest microtron to the largest synchrotron, that have had an enormous impact in almost every branch of science and in several areas of medicine and industry. Cyclotrons themselves have proved remarkably adaptable, incorporating a variety of new ideas and technologies over the years: frequency modulation, edge focusing, AG focusing, separate magnet sectors, axial and azimuthal injection, ring geometries, stripping extraction, superconducting magnets and rf...... Even FFAGs, those most complex members of the cyclotron (fixed-magnetic-field) family, are making a comeback. Currently there are more than 50 medium or large cyclotrons around the world devoted to research. These provide intense primary beams of protons or stable ions, and correspondingly intense secondary beams of neutrons, pions, muons and radioactive ions, for experiments in nuclear, particle and condensed-matter physics, and in the materials and life sciences. Far outnumbering these, however, are the 800 or so small and medium cyclotrons used to produce radioisotopes for medical and other purposes. In addition, a rapidly growing number of 230-MeV proton cyclotrons are being built for cancer therapy -12 brought into operation since 1998 and as many more in the works. Altogether, cyclotrons are flourishing!

  14. Electron cyclotron resonance plasma photos

    SciTech Connect

    Racz, R.; Palinkas, J.; Biri, S.

    2010-02-15

    In order to observe and study systematically the plasma of electron cyclotron resonance (ECR) ion sources (ECRIS) we made a high number of high-resolution visible light plasma photos and movies in the ATOMKI ECRIS Laboratory. This required building the ECR ion source into an open ECR plasma device, temporarily. An 8MP digital camera was used to record photos of plasmas made from Ne, Ar, and Kr gases and from their mixtures. We studied and recorded the effect of ion source setting parameters (gas pressure, gas composition, magnetic field, and microwave power) to the shape, color, and structure of the plasma. The analysis of the photo series gave us many qualitative and numerous valuable physical information on the nature of ECR plasmas.

  15. All-magnetic extraction for cyclotron beam reacceleration

    DOEpatents

    Hudson, E.D.; Mallory, M.L.

    1975-07-22

    An isochronous cyclotron can be modified to provide an initial electron stripping stage, a complete acceleration of the stripped ions through the cyclotron to a first energy state, means for returning the ions to an intermediate cyclotron orbit through a second stripping stage, further acceleration of the now higher energy stripped ions through the cyclotron to their final energy, and final extraction of the ions from the cyclotron. (auth)

  16. Community Relations Plan for Lawrence Berkeley Laboratory. Environmental Restoration Program

    SciTech Connect

    Not Available

    1993-07-01

    The Lawrence Berkeley Laboratory (LBL) has applied to the California Environmental Protection Agency, Department of Toxic Substances Control (DTSC), for renewal of its Hazardous Waste Handling Facility Permit. A permit is required under Resource Conservation and Recovery Act (RCRA) regulations. The permit will allow LBL to continue using its current hazardous waste handling facility, upgrade the existing facility, and construct a replacement facility. The new facility is scheduled for completion in 1995. The existing facility will be closed under RCRA guidelines by 1996. As part of the permitting process, LBL is required to investigate areas of soil and groundwater contamination at its main site in the Berkeley Hills. The investigations are being conducted by LBL`s Environmental Restoration Program and are overseen by a number of regulatory agencies. The regulatory agencies working with LBL include the California Environmental Protection Agency`s Department of Toxic Substances Control, the California Regional Water Quality Control Board, the Bay Area Air Quality Management District, the East Bay Municipal Utilities District, and the Berkeley Department of Environmental Health. RCRA requires that the public be informed of LBL`s investigations and site cleanup, and that opportunities be available for the public to participate in making decisions about how LBL will address contamination issues. LBL has prepared this Community Relations Plan (CRP) to describe activities that LBL will use to keep the community informed of environmental restoration progress and to provide for an open dialogue with the public on issues of importance. The CRP documents the community`s current concerns about LBL`s Environmental Restoration Program. Interviews conducted between February and April 1993 with elected officials, agency staff, environmental organizations, businesses, site neighbors, and LBL employees form the basis for the information contained in this document.

  17. Lipoprotein subclasses in genetic studies: The Berkeley Data Set

    SciTech Connect

    Krauss, R.M.; Williams, P.T.; Blanche, P.J.; Cavanaugh, A.; Holl, L.G.; Austin, M.A.

    1992-10-01

    Data from the Berkeley Data Set was used to investigate familial correlations of HDL-subclasses. Analysis of the sibling intraclass correlation coefficient by HDL particle diameter showed that sibling HDL levels were significantly correlated for HDL{sub 2b}, HDL{sub 3a} and HDL{sub 3b} subclasses. The percentage of the offsprings` variance explained by their two parents. Our finding that parents and offspring-have the highest correlation for HDL{sub 2b} is consistent with published reports that show higher heritability estimates for HDL{sub 2} compared with HDL{sub 3}{minus} cholesterol.

  18. Lawrence Berkeley National Laboratory 1997 Site Environmental Report Vol. II

    SciTech Connect

    Thorson, Patrick

    1998-09-30

    Volume II of the Site Environmental Report for 1997 is published by Ernest Orlando Lawrence Berkeley National Laboratory as a supplemental appendix to the report printed in volume I. Volume II contains the environmental monitoring and sampling data used to generate summary results in the main report for routine and nonroutine activities at the Laboratory (except for groundwater sampling data). Data presented in volume II are given in Systeme International (SI) units. The list below categorizes the volume II data sections with corresponding summary result tables in volume I: Stack Air, Ambient Air, Rainwater, Creeks, Creek Baseline Study, Hydraugers, Lakes, Stormwater, Sewer, Fixed Treatment Units, Soil, Sediment, Vegetation.

  19. Heinz Heinemann. The Berkeley Years (1978-1993)

    SciTech Connect

    Coble, Inger M.

    2009-08-27

    Heinz Heineman came to Berkeley in 1978 and stayed there for 15 years. This was the time of the energy crisis and we did not have anybody like him who had such a tremendous industrial experience with oil and coal conversion technology and science. He was interested in the conversion of coal to gaseous molecules and our studies with model catalysts appealed to him and attracted him. In a way, Heinz Heineman was bigger than life, since he played such a seminal role in the history of American catalysis science.

  20. Assembly Manual for the Berkeley Lab Cosmic Ray Detector

    SciTech Connect

    Collier, Michael

    2002-12-17

    The Berkeley Lab Cosmic Ray Detector consists of 3 main components that must be prepared separately before they can be assembled. These components are the scintillator, circuit board, and casing. They are described in the main sections of this report, which may be completed in any order. Preparing the scintillator paddles involves several steps--cutting the scintillator material to the appropriate size and shape, preparing and attaching Lucite cookies (optional), polishing the edges, gluing the end to the photomultiplier tube (optional), and wrapping the scintillator. Since the detector has 2 paddles, each of the sections needs to be repeated for the other paddle.

  1. Popular Berkeley Lab X-ray Data Booklet reissued

    SciTech Connect

    Robinson, Art

    2001-03-02

    X-ray scientists and synchrotron-radiation users who have been patiently waiting for an updated version of the popular X-Ray Data Booklet last published in 1986 by the Center for X-Ray Optics at the Lawrence Berkeley National Laboratory can breathe a sigh of relief. The venerable ''little orange book'' has now been reissued under the auspices of CXRO and the Advanced Light Source (ALS) with an April printing of 10,000 paper copies and the posting of a Web edition at http://xdb.lbl.gov.

  2. High speed optical links between LLNL and Berkeley

    SciTech Connect

    Lennon, W.J.; Thombley, R.L.

    1994-08-08

    The Advanced Telecommunications Program at Lawrence Livermore National Laboratory, in collaboration with Pacific Bell, is developing an experimental high speed, four wavelength, protocol independent optical link for evaluating wide area networking interconnection schemes and the use of fiber amplifiers. Lawrence Livermore National Laboratory, as a super-user, supercomputer, and super-application site, is anticipating the future bandwidth and protocol requirements to connect to other such sites as well as to connect to remote sited control centers and experiments. In this paper we discuss our vision of the future of Wide Area Networking and describe the plans for the wavelength division multiplexed link between Livermore and the University of California at Berkeley.

  3. Lawrence Berkeley National Laboratory 1995 site environmental report

    SciTech Connect

    Balgobin, D.; Javandel, I.; Lackner, G.; Smith, C.; Thorson, P.; Tran, H.

    1996-07-01

    The 1995 Site Environmental Report summarizes environmental activities at the Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) for the 1995 calendar year. The report strives to present environmental data in a manner that characterizes the performance and compliance status of the environmental management programs. The report also discusses significant highlights and plans of these programs. Topics discussed include: environmental monitoring, environmental compliance programs, air quality, water quality, ground water protection, sanitary sewer monitoring, soil and sediment quality, vegetation and foodstuffs monitoring, and special studies which include preoperational monitoring of building 85 and 1995 sampling results, radiological dose assessment, and quality assessment.

  4. Annual environmental monitoring report of the Lawrence Berkeley Laboratory

    SciTech Connect

    Schleimer, G.E.

    1989-06-01

    The Environmental Monitoring Program of the Lawrence Berkeley Laboratory (LBL) is described. Data for 1988 are presented and general trends are discussed. In order to establish whether LBL research activities produced any impact on the population surrounding the laboratory, a program of environmental air and water sampling and continuous radiation monitoring was carried on throughout the year. For 1988, as in the previous several years, dose equivalents attributable to LBL radiological operations were a small fraction of both the relevant radiation protection guidelines (RPG) and of the natural radiation background. 16 refs., 7 figs., 21 tabs.

  5. USING DOE-2.1 AT LAWRENCE BERKELEY LABORATORY

    SciTech Connect

    Building Energy Analysis Group.; Authors, Various

    1980-09-01

    The purpose of this manual is to assist the DOE-2 user to run DOE-2 and its utility programs at Lawrence Berkeley Laboratory (LBL). It is organized to reflect the facts that every DOE-2 job run at LBL requires certain steps, and that there are options related to DOE-2 job runs available to any DOE-2 user. The standard steps for running a DOE-2 job are as follows: 1. Prepare a job deck 2. Process a job deck 3. Obtain standard output reports.

  6. Method and apparatuses for ion cyclotron spectrometry

    DOEpatents

    Dahl, David A.; Scott, Jill R.; McJunkin, Timothy R.

    2012-03-06

    An ion cyclotron spectrometer may include a vacuum chamber that extends at least along a z-axis and means for producing a magnetic field within the vacuum chamber so that a magnetic field vector is generally parallel to the z-axis. The ion cyclotron spectrometer may also include means for producing a trapping electric field within the vacuum chamber. The trapping electric field may comprise a field potential that, when taken in cross-section along the z-axis, includes at least one section that is concave down and at least one section that is concave up so that ions traversing the field potential experience a net magnetron effect on a cyclotron frequency of the ions that is substantially equal to zero. Other apparatuses and a method for performing ion cyclotron spectrometry are also disclosed herein.

  7. RCNP cyclotron facility and application program

    NASA Astrophysics Data System (ADS)

    Hatanaka, Kichiji

    2013-05-01

    The RCNP cyclotron cascade system consists of K140 AVF cyclotron and K400 ring cyclotron and is providing high quality beams for various experiments. Three kinds of neutron sources are developed for applications as well as fundamental physics. They provide monoenergetic neutrons at 10-400 MeV, white neutrons with the same energy spectra as terrestrial neutrons on the earth, and ultra cold neutrons with energies below 210 neV. There are increasing demands for high intensity beams and even to improve the quality. In order to increase the physics research opportunities, a new injector cyclotron is proposed, which has four separated sector magnets and two accelerating cavities. Sector magnets are designed to use High Temperature Superconducting (HTS) wire. At RCNP, we have been developing magnets with HTS wires for a decade.

  8. Development of a Medical Cyclotron Production Facility

    NASA Astrophysics Data System (ADS)

    Allen, Danny R.

    2003-08-01

    Development of a Cyclotron manufacturing facility begins with a business plan. Geographics, the size and activity of the medical community, the growth potential of the modality being served, and other business connections are all considered. This business used the customer base established by NuTech, Inc., an independent centralized nuclear pharmacy founded by Danny Allen. With two pharmacies in operation in Tyler and College Station and a customer base of 47 hospitals and clinics the existing delivery system and pharmacist staff is used for the cyclotron facility. We then added cyclotron products to contracts with these customers to guarantee a supply. We partnered with a company in the process of developing PET imaging centers. We then built an independent imaging center attached to the cyclotron facility to allow for the use of short-lived isotopes.

  9. Electron cyclotron wave generation by relativistic electrons

    NASA Technical Reports Server (NTRS)

    Wong, H. K.; Goldstein, M. L.

    1994-01-01

    We show that an energetic electron distribution which has a temperature anisotropy (T perpendicular to b is greater than T parallel to b), or which is gyrating about a DC magnetic field, can generate electron cyclotron waves with frequencies below the electron cyclotron frequency. Relativistic effects are included in solving the dispersion equation and are shown to be quantitatively important. The basic idea of the mechanism is the coupling of the beam mode to slow waves. The unstable electron cyclotron waves are predominantly electromagnetic and right-hand polarized. For a low-density plasma in which the electron plasma frequency is less than the electron cyclotron frequency, the excited waves can have frequencies above or below the electron plasma frequency, depending upon the parameters of the energetic electron distribution. This instability may account for observed Z mode waves in the polar magnetosphere of the Earth and other planets.

  10. Low energy cyclotron for radiocarbon dating

    SciTech Connect

    Welch, J.J.

    1985-01-01

    The author built and tested a low energy cyclotron for radiocarbon dating similar to a conventional mass spectrometer. These tests clearly show that with the addition of a conventional ion source, the low energy cyclotron can perform the extremely high sensitivity /sup 14/C measurements that are now done at accelerator facilities. The author found that no significant background is present when the cyclotron is tuned to accelerate /sup 14/C negative ions and the transmission efficiency is adequate to perform radiocarbon dating on milligram samples of carbon. The internal ion source used did not produce sufficient current to detect /sup 14/C directly at modern concentrations. The author shows how a conventional carbon negative ion source located outside the cyclotron magnet, would produce sufficient beam and provide for quick sample changing to make radiocarbon dating milligram samples with a modest laboratory instrument feasible.

  11. Building 211 cyclotron characterization survey report

    SciTech Connect

    1998-03-30

    The Building 211 Cyclotron Characterization Survey includes an assessment of the radioactive and chemical inventory of materials stored within the facility; an evaluation of the relative distribution of accelerator-produced activation products within various cyclotron components and adjacent structures; measurement of the radiation fields throughout the facility; measurement and assessment of internal and external radioactive surface contamination on various equipment, facility structures, and air-handling systems; and an assessment of lead (Pb) paint and asbestos hazards within the facility.

  12. Cyclotron axial ion-beam-buncher system

    SciTech Connect

    Hamm, R.W.; Swenson, D.A.; Wangler, T.P.

    1982-02-11

    Adiabatic ion bunching is achieved in a cyclotron axial ion injection system through the incorporation of a radio frequency quadrupole system, which receives ions from an external ion source via an accelerate-decelerate system and a focusing einzel lens system, and which adiabatically bunches and then injects the ions into the median plane of a cyclotron via an electrostatic quadrupole system and an inflection mirror.

  13. Rotatable superconducting cyclotron adapted for medical use

    DOEpatents

    Blosser, Henry G.; Johnson, David A.; Riedel, Jack; Burleigh, Richard J.

    1985-01-01

    A superconducting cyclotron (10) rotatable on a support structure (11) in an arc of about 180.degree. around a pivot axis (A--A) and particularly adapted for medical use is described. The rotatable support structure (13, 15) is balanced by being counterweighted (14) so as to allow rotation of the cyclotron and a beam (12), such as a subparticle (neutron) or atomic particle beam, from the cyclotron in the arc around a patient. Flexible hose (25) is moveably attached to the support structure for providing a liquified gas which is supercooled to near 0.degree. K. to an inlet means (122) to a chamber (105) around superconducting coils (101, 102). The liquid (34) level in the cyclotron is maintained approximately half full so that rotation of the support structure and cyclotron through the 180.degree. can be accomplished without spilling the liquid from the cyclotron. With the coils vertically oriented, each turn of the winding is approximately half immersed in liquid (34) and half exposed to cold gas and adequate cooling to maintain superconducting temperatures in the section of coil above the liquid level is provided by the combination of cold gas/vapor and by the conductive flow of heat along each turn of the winding from the half above the liquid to the half below.

  14. Environmental assessment for construction and operation of a Human Genome Laboratory at Lawrence Berkeley Laboratory, Berkeley, California

    SciTech Connect

    1994-12-01

    Lawrence Berkeley Laboratory (LBL) proposes to construct and operate a new laboratory for consolidation of current and future activities of the Human Genome Center (HGC). This document addresses the potential direct, indirect, and cumulative environmental and human-health effects from the proposed facility construction and operation. This document was prepared in accordance the National Environmental Policy Act of 1969 (United States Codes 42 USC 4321-4347) (NEPA) and the US Department of Energy`s (DOE) Final Rule for NEPA Implementing Procedures [Code of Federal Regulations 10CFR 1021].

  15. Clean option: Berkeley Pit water treatment and resource recovery strategy

    SciTech Connect

    Gerber, M.A.; Orth, R.J.; Elmore, M.R.; Monzyk, B.F.

    1995-09-01

    The US Department of Energy (DOE), Office of Technology Development, established the Resource Recovery Project (RRP) in 1992 as a five-year effort to evaluate and demonstrate multiple technologies for recovering water, metals, and other industrial resources from contaminated surface and groundwater. Natural water resources located throughout the DOE complex and the and western states have been rendered unusable because of contamination from heavy metals. The Berkeley Pit, a large, inactive, open pit copper mine located in Butte, Montana, along with its associated groundwater system, has been selected by the RRP for use as a feedstock for a test bed facility located there. The test bed facility provides the infrastructure needed to evaluate promising technologies at the pilot plant scale. Data obtained from testing these technologies was used to assess their applicability for similar mine drainage water applications throughout the western states and at DOE. The objective of the Clean Option project is to develop strategies that provides a comprehensive and integrated approach to resource recovery using the Berkeley Pit water as a feedstock. The strategies not only consider the immediate problem of resource recovery from the contaminated water, but also manage the subsequent treatment of all resulting process streams. The strategies also employ the philosophy of waste minimization to optimize reduction of the waste volume requiring disposal, and the recovery and reuse of processing materials.

  16. Berkeley extreme-ultraviolet airglow rocket spectrometer: BEARS.

    PubMed

    Cotton, D M; Chakrabarti, S

    1992-09-20

    We describe the Berkeley extreme-UV airglow rocket spectrometer, which is a payload designed to test several thermospheric remote-sensing concepts by measuring the terrestrial O I far-UV and extreme-UV dayglow and the solar extreme-UV spectrum simultaneously. The instrument consisted of two near-normal Rowland mount spectrometers and a Lyman-alpha photometer. The dayglow spectrometer covered two spectral regions from 980 to 1040 A and from 1300 to 1360 A with 1.5-A resolution. The solar spectrometer had a bandpass of 250-1150 A with an ~ 10-A resolution. All three spectra were accumulated by using a icrochannel-plate-intensified, two-dimensional imaging detector with three separate wedge-and strip anode readouts. The hydrogen Lyman-alpha photometer was included to monitor the solar Lyman-alpha irradiance and geocoronal Lyman-alpha emissions. The instrument was designed, fabricated, and calibrated at the University of California, Berkeley and was successfully launched on 30 September 1988 aboard the first test flight of a four-stage sounding rocket, Black Brant XII. PMID:20733778

  17. Environmental Assessment for the proposed Induction Linac System Experiments in Building 51B at Lawrence Berkeley National Laboratory, Berkeley, California

    SciTech Connect

    1995-08-01

    The US Department of Energy (DOE) has prepared an Environmental Assessment (EA), (DOE/EA-1087) evaluating the proposed action to modify existing Building 51B at Lawrence Berkeley National Laboratory (LBNL) to install and conduct experiments on a new Induction Linear Accelerator System. LBNL is located in Berkeley, California and operated by the University of California (UC). The project consists of placing a pre-fabricated building inside Building 51B to house a new 10 MeV heavy ion linear accelerator. A control room and other support areas would be provided within and directly adjacent to Building 51B. The accelerator system would be used to conduct tests, at reduced scale and cost, many features of a heavy-ion accelerator driver for the Department of Energy`s inertial fusion energy program. Based upon information and analyses in the EA, the DOE has determined that the proposed action is not a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969. Therefore, an Environmental Impact Statement is not required. This report contains the Environmental Assessment, as well as the Finding of No Significant Impact (FONSI).

  18. The Lawrence Berkeley Laboratory geothermal program in northern Nevada

    NASA Technical Reports Server (NTRS)

    Mirk, K. F.; Wollenberg, H. A.

    1974-01-01

    The Lawrence Berkeley Laboratory's geothermal program began with consideration of regions where fluids in the temperature range of 150 to 230 C may be economically accessible. Three valleys, located in an area of high regional heat flow in north central Nevada, were selected for geological, geophysical, and geochemical field studies. The objective of these ongoing field activities is to select a site for a 10-MW demonstration plant. Field activities (which started in September 1973) are described. A parallel effort has been directed toward the conceptual design of a 10-MW isobutane binary plant which is planned for construction at the selected site. Design details of the plant are described. Project schedule with milestones is shown together with a cost summary of the project.

  19. Berkeley Program Offers New Option for Financing Residential PV Systems

    SciTech Connect

    Bolinger, Mark A

    2008-07-06

    Readily accessible credit has often been cited as a necessary ingredient to open up the market for residential photovoltaic (PV) systems. Though financing does not reduce the high up-front cost of PV, by spreading that cost over some portion of the system's life, financing can certainly make PV systems more affordable. As a result, a number of states have, in the past, set up special residential loan programs targeting the installation of renewable energy systems and/or energy-efficiency improvements and often featuring low interest rates, longer terms and no-hassle application requirements. Historically, these loan programs have had mixed success (particularly for PV), for a variety of reasons, including a historical lack of homeowner interest in PV, a lack of program awareness, a reduced appeal in a low-interest-rate environment, and a tendency for early PV adopters to be wealthy and not in need of financing. Some of these barriers have begun to fade. Most notably, homeowner interest in PV has grown in some states, particularly those that offer solar rebates. The passage of the Energy Policy Act of 2005 (EPAct 2005), however, introduced one additional roadblock to the success of low-interest PV loan programs: a residential solar investment tax credit (ITC), subject to the Federal government's 'anti-double-dipping' rules. Specifically, the residential solar ITC--equal to 30% of the system's tax basis, capped at $2000--will be reduced or offset if the system also benefits from what is known as 'subsidized energy financing', which is likely to include most government-sponsored low-interest loan programs. Within this context, it has been interesting to note the recent flurry of announcements from a number of U.S cities concerning a new type of PV financing program. Led by the city of Berkeley, Calif., these cities propose to offer their residents the ability to finance the installation of a PV system using increased property tax assessments, rather than a more

  20. Lawrence Berkeley Laboratory Self-Assessment Program: Implementation Plan

    SciTech Connect

    Not Available

    1992-06-01

    The Lawrence Berkeley Laboratory (LBL) Self-Assessment Program provides a formal process for assuring quality and regulatory compliance in all facets of Laboratory operations. The program, which integrates the ongoing self-assessment activities of the individual Divisions and Offices in a comprehensive, top-to-bottom process, provides assistance to the US Department of Energy (DOE), the University of California, and Laboratory management in their appraisals of Laboratory performance. This document describes the program goals, scope, responsibilities, elements, and implementation schedule. This document is also the implementation plan for the institutional level self-assessment program. Each Division is also required to develop a self-assessment program that contains the elements described in this document.

  1. Low energy cyclotron for radiocarbon dating

    SciTech Connect

    Welch, J.J.

    1984-12-01

    The measurement of naturally occurring radioisotopes whose half lives are less than a few hundred million years but more than a few years provides information about the temporal behavior of geologic and climatic processes, the temporal history of meteoritic bodies as well as the production mechanisms of these radioisotopes. A new extremely sensitive technique for measuring these radioisotopes at tandem Van de Graaff and cyclotron facilities has been very successful though the high cost and limited availability have been discouraging. We have built and tested a low energy cyclotron for radiocarbon dating similar in size to a conventional mass spectrometer. These tests clearly show that with the addition of a conventional ion source, the low energy cyclotron can perform the extremely high sensitivity /sup 14/C measurements that are now done at accelerator facilities. We found that no significant background is present when the cyclotron is tuned to accelerate /sup 14/C negative ions and the transmission efficiency is adequate to perform radiocarbon dating on milligram samples of carbon. The internal ion source used did not produce sufficient current to detect /sup 14/C directly at modern concentrations. We show how a conventional carbon negative ion source, located outside the cyclotron magnet, would produce sufficient beam and provide for quick sampling to make radiocarbon dating milligram samples with a modest laboratory instrument feasible.

  2. Morphological and functional platelet abnormalities in Berkeley sickle cell mice.

    PubMed

    Shet, Arun S; Hoffmann, Thomas J; Jirouskova, Marketa; Janczak, Christin A; Stevens, Jacqueline R M; Adamson, Adewole; Mohandas, Narla; Manci, Elizabeth A; Cynober, Therese; Coller, Barry S

    2008-01-01

    Berkeley sickle cell mice are used as animal models of human sickle cell disease but there are no reports of platelet studies in this model. Since humans with sickle cell disease have platelet abnormalities, we studied platelet morphology and function in Berkeley mice (SS). We observed elevated mean platelet forward angle light scatter (FSC) values (an indirect measure of platelet volume) in SS compared to wild type (WT) (37+/-3.2 vs. 27+/-1.4, mean+/-SD; p<0.001), in association with moderate thrombocytopenia (505+/-49 x 10(3)/microl vs. 1151+/-162 x 10(3)/microl; p<0.001). Despite having marked splenomegaly, SS mice had elevated levels of Howell-Jolly bodies and "pocked" erythrocytes (p<0.001 for both) suggesting splenic dysfunction. SS mice also had elevated numbers of thiazole orange positive platelets (5+/-1% vs. 1+/-1%; p<0.001), normal to low plasma thrombopoietin levels, normal plasma glycocalicin levels, normal levels of platelet recovery, and near normal platelet life spans. Platelets from SS mice bound more fibrinogen and antibody to P-selectin following activation with a threshold concentration of a protease activated receptor (PAR)-4 peptide compared to WT mice. Enlarged platelets are associated with a predisposition to arterial thrombosis in humans and some humans with SCD have been reported to have large platelets. Thus, additional studies are needed to assess whether large platelets contribute either to pulmonary hypertension or the large vessel arterial occlusion that produces stroke in some children with sickle cell disease. PMID:18374611

  3. Development of a pepper-pot device to determine the emittance of an ion beam generated by electron cyclotron resonance ion sources

    SciTech Connect

    Strohmeier, M.; Benitez, J. Y.; Leitner, D.; Lyneis, C. M.; Todd, D. S.; Bantel, M.

    2010-02-15

    This paper describes the recent development and commissioning of a pepper-pot emittance meter at the Lawrence Berkeley National Laboratory (LBNL). It is based on a potassium bromide (KBr) scintillator screen in combination with a charged coupled device camera. Pepper-pot scanners record the full four-dimensional transverse phase space emittances which are particularly interesting for electron cyclotron resonance ion sources. The strengths and limitations of evaluating emittances using optical pepper-pot scanners are described and systematic errors induced by the optical data acquisition system will be presented. Light yield tests of KBr exposed to different ion species and first emittance measurement data using ion beams extracted from the 6.4 GHz LBNL electron cyclotron resonance ion source are presented and discussed.

  4. Development of a pepper-pot device to determine the emittance of an ion beam generated by electron cyclotron resonance ion sources.

    PubMed

    Strohmeier, M; Benitez, J Y; Leitner, D; Lyneis, C M; Todd, D S; Bantel, M

    2010-02-01

    This paper describes the recent development and commissioning of a pepper-pot emittance meter at the Lawrence Berkeley National Laboratory (LBNL). It is based on a potassium bromide (KBr) scintillator screen in combination with a charged coupled device camera. Pepper-pot scanners record the full four-dimensional transverse phase space emittances which are particularly interesting for electron cyclotron resonance ion sources. The strengths and limitations of evaluating emittances using optical pepper-pot scanners are described and systematic errors induced by the optical data acquisition system will be presented. Light yield tests of KBr exposed to different ion species and first emittance measurement data using ion beams extracted from the 6.4 GHz LBNL electron cyclotron resonance ion source are presented and discussed. PMID:20192450

  5. Narrative and Spectacle in the Hollywood Musical: Contrasting the Choreography of Busby Berkeley and Gene Kelly

    ERIC Educational Resources Information Center

    Pattullo, Lauren

    2007-01-01

    This paper examines the relationship between narrative and spectacle in the Hollywood musical, with reference to the work of Busby Berkeley and Gene Kelly. It discusses Busby Berkeley's "backstage" musicals in terms of his "aggregate" approach to dealing with the narrative/spectacle relationship, and considers the effect of the backstage musical's…

  6. Interpretive Experiments: An Interpretive Experiment in Ion Cyclotron Resonance Spectroscopy.

    ERIC Educational Resources Information Center

    Burnier, R. C.; Freiser, B. S.

    1979-01-01

    Provides a discussion which is intended for chemistry college students on the ion cyclotron resonance (ICR) spectroscopy, the physical basis for ion cyclotron resonance, and the experimental methodology employed by ICR spectroscopists. (HM)

  7. Computer modeling of a compact isochronous cyclotron

    NASA Astrophysics Data System (ADS)

    Smirnov, V. L.

    2015-11-01

    The computer modeling methods of a compact isochronous cyclotron are described. The main stages of analysis of accelerator facilities systems are considered. The described methods are based on theoretical fundamentals of cyclotron physics and mention highlights of creation of the physical project of a compact cyclotron. The main attention is paid to the analysis of the beam dynamics, formation of a magnetic field, stability of the movement, and a realistic assessment of intensity of the generated bunch of particles. In the article, the stages of development of the accelerator computer model, analytical ways of assessment of the accelerator parameters, and the basic technique of the numerical analysis of dynamics of the particles are described.

  8. Improving cancer treatment with cyclotron produced radionuclides

    SciTech Connect

    Larson, S.M. Finn, R.D.

    1992-08-04

    This report describes the author's continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program has 3 interactive components: Radiochemistry /Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section under the DOE grant during the 1989--1992 grant period, will be employed in the Pharmacology and Immunology sections of the DOE grant during the 1992--1995 grant period. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  9. Cyclotron maser emission: Stars, planets, and laboratory

    SciTech Connect

    Vorgul, I.; Cairns, R. A.; Kellett, B. J.; Bingham, R.; Ronald, K.; Speirs, D. C.; McConville, S. L.; Gillespie, K. M.; Phelps, A. D. R.

    2011-05-15

    This paper is a review of results by the group over the past decade on auroral kilometric radiation and similar cyclotron emissions from stars and planets. These emissions are often attributed to a horseshoe or crescent shaped momentum distribution of energetic electrons moving into the convergent magnetic field which exists around polar regions of dipole-type stars and planets. We have established a laboratory-based facility that has verified many of the details of our original theoretical description and agrees well with numerical simulations. The experiment has demonstrated that the horseshoe distribution does indeed produce cyclotron emission at a frequency just below the local cyclotron frequency, with polarization close to X-mode and propagating nearly perpendicularly to the beam motion. We discuss recent developments in the theory and simulation of the instability including addressing a radiation escape problem and the effect of competing instabilities, relating these to the laboratory, space, and astrophysical observations.

  10. The electromagnetic ion cyclotron beam anisotropy instability

    NASA Technical Reports Server (NTRS)

    Peter Gary, S.; Schriver, David

    1987-01-01

    Electromagnetic instabilities driven by an anisotropic, relatively cool ion beam are studied for the case in which both the beam and the instabilities propagate parallel or antiparallel to a uniform magnetic field. At modest beam-core relative drift speeds, sufficiently large perpendicular-to-parallel beam temperature ratios and sufficiently large plasma beta, the mode of fastest growth rate is the ion cyclotron beam anisotropy instability. Because the right-hand polarized waves observed upstream of slow shocks in the earth's magnetotail can lead to the appropriate beam anisotropy, the ion cyclotron instability may be present and account for the left-hand polarized magnetic waves observed there. Also, because of its relatively low phase speed, the ion cyclotron beam anisotropy instability may provide the scattering necessary for ion Fermi acceleration at slow shocks of sufficiently high plasma beta.

  11. Improvements and applications at NIRS cyclotron facility

    NASA Astrophysics Data System (ADS)

    Honma, T.; Hojo, S.; Miyahara, N.; Nemoto, K.; Sato, Y.; Suzuki, K.; Takada, M.; Yamada, S.; Kuramochi, Y.; Okada, T.; Hanagasaki, M.; Komatsu, K.; Ogawa, H.

    2001-12-01

    The NIRS-Chiba isochronous cyclotron has been working in routinely, and providing the stable beams for bio-medical studies and various kind of related experiments since 1975. The clinical trail of eye melanoma has been under continued. Recently two new beam lines were constructed in order to carry out the bio-physical study, and to produce the long-lived R.I.s for SPECT. Some progressive improvements, such as updating the magnetic-channel and development of a floating septum system, were performed for stable operation of the cyclotron. A brief review of the current status of the cyclotron and typical application of latest experiments in the various fields are described.

  12. A room temperature electron cyclotron resonance ion source for the DC-110 cyclotron

    SciTech Connect

    Efremov, A. Bogomolov, S.; Lebedev, A.; Loginov, V.; Yazvitsky, N.

    2014-02-15

    The project of the DC-110 cyclotron facility to provide applied research in the nanotechnologies (track pore membranes, surface modification of materials, etc.) has been designed by the Flerov Laboratory of Nuclear Reactions of the Joint Institute for Nuclear Research (Dubna). The facility includes the isochronous cyclotron DC-110 for accelerating the intensive Ar, Kr, Xe ion beams with 2.5 MeV/nucleon fixed energy. The cyclotron is equipped with system of axial injection and ECR ion source DECRIS-5, operating at the frequency of 18 GHz. This article reviews the design and construction of DECRIS-5 ion source along with some initial commissioning results.

  13. Low-background-rate detector for ions in the 5- to 50-keV energy range to be used for radioisotope dating with a small cyclotron

    SciTech Connect

    Friedman, P.G.

    1986-01-01

    Accelerator mass spectrometry in tandem Van de Graaff accelerators has proven successful for radioisotope dating small samples. Small, inexpensive cyclotrons serving this purpose would make the technique accessible to more researchers and inexpensive enough to compare many small samples. To this end, VC Berkeley is developing a 20-cm-diameter, 30- to 40-keV cyclotron dedicated to high-sensitivity radioisotope dating, initially for /sup 14/C. At this energy, range and dE/dx methods of particle identification are impossible. Thus arises the difficult problem of reliably detecting 30- to 40-keV /sup 14/C at 10/sup -1/ counts/sec in the high-background environment of the cyclotron, where lower energy ions, electrons, and photons bombard the detector at much higher rates. To meet this challenge, an inexpensive, generally useful ion detector was developed that allows dark-count rates below 10/sup -4/ counts/sec and excellent background suppression. With the cyclotron tuned near the /sup 13/CH background peak, to the frequency for /sup 14/C, the detector suppresses the background to 6 x 10/sup -4/ counts/sec. For each /sup 14/C ion, the detector's grazing-incidence Al/sub 2/O/sub 3/ conversion dynode emits about 20 secondary electrons, which are independently multiplied in separate pores of a microchannel plate. The output signal is proportional to the number of secondary electrons, allowing pulse-height discrimination of background.

  14. Imaging Cyclotron Orbits of Electrons in Graphene.

    PubMed

    Bhandari, Sagar; Lee, Gil-Ho; Klales, Anna; Watanabe, Kenji; Taniguchi, Takashi; Heller, Eric; Kim, Philip; Westervelt, Robert M

    2016-03-01

    Electrons in graphene can travel for several microns without scattering at low temperatures, and their motion becomes ballistic, following classical trajectories. When a magnetic field B is applied perpendicular to the plane, electrons follow cyclotron orbits. Magnetic focusing occurs when electrons injected from one narrow contact focus onto a second contact located an integer number of cyclotron diameters away. By tuning the magnetic field B and electron density n in the graphene layer, we observe magnetic focusing peaks. We use a cooled scanning gate microscope to image cyclotron trajectories in graphene at 4.2 K. The tip creates a local change in density that casts a shadow by deflecting electrons flowing nearby; an image of flow can be obtained by measuring the transmission between contacts as the tip is raster scanned across the sample. On the first magnetic focusing peak, we image a cyclotron orbit that extends from one contact to the other. In addition, we study the geometry of orbits deflected into the second point contact by the tip. PMID:26845290

  15. Ion-cyclotron instability in magnetic mirrors

    SciTech Connect

    Pearlstein, L.D.

    1987-02-02

    This report reviews the role of ion-cyclotron frequency instability in magnetic mirrors. The modes discussed here are loss-cone or anisotropy driven. The discussion includes quasilinear theory, explosive instabilities of 3-wave interaction and non-linear Landau damping, and saturation due to non-linear orbits. (JDH)

  16. Cyclotron-based neutron source for BNCT

    SciTech Connect

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K.; Tanaka, H.; Sakurai, Y.; Maruhashi, A.

    2013-04-19

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation and treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8 Multiplication-Sign 109 neutrons/cm{sup 2}/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with {sup 10}B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  17. Numerical investigation of auroral cyclotron maser processes

    SciTech Connect

    Speirs, D. C.; Ronald, K.; McConville, S. L.; Gillespie, K. M.; Phelps, A. D. R.; Cross, A. W.; Robertson, C. W.; Whyte, C. G.; He, W.; Bingham, R.; Vorgul, I.; Cairns, R. A.; Kellett, B. J.

    2010-05-15

    When a mainly rectilinear electron beam is subject to significant magnetic compression, conservation of magnetic moment results in the formation of a horseshoe shaped velocity distribution. It has been shown that such a distribution is unstable to cyclotron emission and may be responsible for the generation of auroral kilometric radiation--an intense rf emission sourced at high altitudes in the terrestrial auroral magnetosphere. Particle-in-cell code simulations have been undertaken to investigate the dynamics of the cyclotron emission process in the absence of cavity boundaries with particular consideration of the spatial growth rate, spectral output and rf conversion efficiency. Computations reveal that a well-defined cyclotron emission process occurs albeit with a low spatial growth rate compared with waveguide bounded simulations. The rf output is near perpendicular to the electron beam with a slight backward-wave character reflected in the spectral output with a well defined peak at 2.68 GHz, just below the relativistic electron cyclotron frequency. The corresponding rf conversion efficiency of 1.1% is comparable to waveguide bounded simulations and consistent with the predictions of kinetic theory that suggest efficient, spectrally well defined emission can be obtained from an electron horseshoe distribution in the absence of radiation boundaries.

  18. Cyclotron-based neutron source for BNCT

    NASA Astrophysics Data System (ADS)

    Mitsumoto, T.; Yajima, S.; Tsutsui, H.; Ogasawara, T.; Fujita, K.; Tanaka, H.; Sakurai, Y.; Maruhashi, A.

    2013-04-01

    Kyoto University Research Reactor Institute (KURRI) and Sumitomo Heavy Industries, Ltd. (SHI) have developed a cyclotron-based neutron source for Boron Neutron Capture Therapy (BNCT). It was installed at KURRI in Osaka prefecture. The neutron source consists of a proton cyclotron named HM-30, a beam transport system and an irradiation & treatment system. In the cyclotron, H- ions are accelerated and extracted as 30 MeV proton beams of 1 mA. The proton beams is transported to the neutron production target made by a beryllium plate. Emitted neutrons are moderated by lead, iron, aluminum and calcium fluoride. The aperture diameter of neutron collimator is in the range from 100 mm to 250 mm. The peak neutron flux in the water phantom is 1.8×109 neutrons/cm2/sec at 20 mm from the surface at 1 mA proton beam. The neutron source have been stably operated for 3 years with 30 kW proton beam. Various pre-clinical tests including animal tests have been done by using the cyclotron-based neutron source with 10B-p-Borono-phenylalanine. Clinical trials of malignant brain tumors will be started in this year.

  19. Physics of Cyclotron Resonance Scattering Features

    NASA Astrophysics Data System (ADS)

    Sschoenherr, Gabriele; Schwarm, Fritz-Walter; Falkner, Sebastian; Dauser, Thomas; Pottschmidt, Katja; Kretschmar, Peter; Klochkov, Dmitry; Ferrigno, Carlo; Britton Hemphill, Paul; Wilms, Joern

    2016-04-01

    Cyclotron resonant scattering features (short: cyclotron lines) are sensitive tracers of the physics of the accretion columns and mounds of X-ray pulsars. They form by interaction of X-ray photons with magnetically quantized electrons in the accreted plasma close to the neutron star. Such lines have been observed as absorption-like features for about 20 X-ray pulsars. Their energies provide a direct measure of the magnetic field strength in the line-forming region. By detailed modelling of the lines and of their parameter dependencies we can further decipher the physical conditions in the accretion column. For instance the fact that the complex scattering cross sections have a strong angle-dependence relates the phase-resolved cyclotron line shapes to parameters that constrain the systems’ still poorly understood geometry. Modelling the physics of cyclotron lines to a degree that allows for detailed and solid comparison to data therefore provides a unique access also to a better understanding of the overall picture of magnetically accreting neutron star systems.

  20. Tokamak startup with electron cyclotron heating

    SciTech Connect

    Holly, D J; Prager, S C; Shepard, D A; Sprott, J C

    1980-04-01

    Experiments are described in which the startup voltage in a tokamak is reduced by approx. 60% by the use of a modest amount of electron cyclotron resonance heating power for preionization. A 50% reduction in volt-second requirement and impurity reflux are also observed.

  1. Spin-Off Successes of SETI Research at Berkeley

    NASA Astrophysics Data System (ADS)

    Douglas, K. A.; Anderson, D. P.; Bankay, R.; Chen, H.; Cobb, J.; Korpela, E. J.; Lebofsky, M.; Parsons, A.; von Korff, J.; Werthimer, D.

    2009-12-01

    Our group contributes to the Search for Extra-Terrestrial Intelligence (SETI) by developing and using world-class signal processing computers to analyze data collected on the Arecibo telescope. Although no patterned signal of extra-terrestrial origin has yet been detected, and the immediate prospects for making such a detection are highly uncertain, the SETI@home project has nonetheless proven the value of pursuing such research through its impact on the fields of distributed computing, real-time signal processing, and radio astronomy. The SETI@home project has spun off the Center for Astronomy Signal Processing and Electronics Research (CASPER) and the Berkeley Open Infrastructure for Networked Computing (BOINC), both of which are responsible for catalyzing a smorgasbord of new research in scientific disciplines in countries around the world. Futhermore, the data collected and archived for the SETI@home project is proving valuable in data-mining experiments for mapping neutral galatic hydrogen and for detecting black-hole evaporation.

  2. Berkeley Lab Checkpoint/Restart (BLCR) for Linux Clusters

    SciTech Connect

    Hargrove, Paul H.; Duell, Jason C.

    2006-07-26

    This article describes the motivation, design andimplementation of Berkeley Lab Checkpoint/Restart (BLCR), a system-levelcheckpoint/restart implementation for Linux clusters that targets thespace of typical High Performance Computing applications, including MPI.Application-level solutions, including both checkpointing andfault-tolerant algorithms, are recognized as more time and spaceefficient than system-level checkpoints, which cannot make use of anyapplication-specific knowledge. However, system-level checkpointingallows for preemption, making it suitable for responding to "faultprecursors" (for instance, elevated error rates from ECC memory ornetwork CRCs, or elevated temperature from sensors). Preemption can alsoincrease the efficiency of batch scheduling; for instance reducing idlecycles (by allowing for shutdown without any queue draining period orreallocation of resources to eliminate idle nodes when better fittingjobs are queued), and reducing the average queued time (by limiting largejobs to running during off-peak hours, without the need to limit thelength of such jobs). Each of these potential uses makes BLCR a valuabletool for efficient resource management in Linux clusters.

  3. Tiger Team assessment of the Lawrence Berkeley Laboratory, Washington, DC

    SciTech Connect

    Not Available

    1991-02-01

    This report documents the results of the Department of Energy's (DOE's) Tiger Team Assessment of the Lawrence Berkeley Laboratory (LBL) conducted from January 14 through February 15, 1991. The purpose of the assessment was to provide the Secretary of Energy with the status of environment, safety, and health (ES H) programs at LBL. The Tiger Team concluded that curtailment of cessation of any operations at LBL is not warranted. However, the number and breadth of findings and concerns from this assessment reflect a serious condition at this site. In spite of its late start, LBL has recently made progress in increasing ES H awareness at all staff levels and in identifying ES H deficiencies. Corrective action plans are inadequate, however, many compensatory actions are underway. Also, LBL does not have the technical expertise or training programs nor the tracking and followup to effectively direct and control sitewide guidance and oversight by DOE of ES H activities at LBL. As a result of these deficiencies, the Tiger Team has reservations about LBL's ability to implement effective actions in a timely manner and, thereby, achieve excellence in their ES H program. 4 figs., 24 tabs.

  4. Berkeley lab checkpoint/restart (BLCR) for Linux clusters

    NASA Astrophysics Data System (ADS)

    Hargrove, Paul H.; Duell, Jason C.

    2006-09-01

    This article describes the motivation, design and implementation of Berkeley Lab Checkpoint/Restart (BLCR), a system-level checkpoint/restart implementation for Linux clusters that targets the space of typical High Performance Computing applications, including MPI. Application-level solutions, including both checkpointing and fault-tolerant algorithms, are recognized as more time and space efficient than system-level checkpoints, which cannot make use of any application-specific knowledge. However, system-level checkpointing allows for preemption, making it suitable for responding to ''fault precursors'' (for instance, elevated error rates from ECC memory or network CRCs, or elevated temperature from sensors). Preemption can also increase the efficiency of batch scheduling; for instance reducing idle cycles (by allowing for shutdown without any queue draining period or reallocation of resources to eliminate idle nodes when better fitting jobs are queued), and reducing the average queued time (by limiting large jobs to running during off-peak hours, without the need to limit the length of such jobs). Each of these potential uses makes BLCR a valuable tool for efficient resource management in Linux clusters.

  5. Modernizing Natural History: Berkeley's Museum of Vertebrate Zoology in Transition.

    PubMed

    Sunderland, Mary E

    2013-01-01

    Throughout the twentieth century calls to modernize natural history motivated a range of responses. It was unclear how research in natural history museums would participate in the significant technological and conceptual changes that were occurring in the life sciences. By the 1960s, the Museum of Vertebrate Zoology at the University of California, Berkeley, was among the few university-based natural history museums that were able to maintain their specimen collections and support active research. The MVZ therefore provides a window to the modernization of natural history. This paper concentrates on the directorial transitions that occurred at the MVZ between 1965 and 1971. During this period, the MVZ had four directors: Alden H. Miller (Director 1940-1965), an ornithologist; Aldo Starker Leopold (Acting Director 1965-1966), a conservationist and wildlife biologist; Oliver P. Pearson (Director 1966-1971), a physiologist and mammalogist; and David B. Wake (Director 1971-1998), a morphologist, developmental biologist, and herpetologist. The paper explores how a diversity of overlapping modernization strategies, including hiring new faculty, building infrastructure to study live animals, establishing new kinds of collections, and building modern laboratories combined to maintain collections at the MVZ's core. The paper examines the tensions between the different modernization strategies to inform an analysis of how and why some changes were institutionalized while others were short-lived. By exploring the modernization of collections-based research, this paper emphasizes the importance of collections in the transformation of the life sciences. PMID:22990484

  6. Visualization and Communication of Pharmacometric Models With Berkeley Madonna

    PubMed Central

    Krause, A; Lowe, P J

    2014-01-01

    Population or other pharmacometric models are a useful means to describe, succinctly, the relationships between drug administration, exposure (concentration), and downstream changes in pharmacodynamic (PD) biomarkers and clinical endpoints, including the mixed effects of patient factors and random interpatient variation (fixed and random effects). However, showing a set of covariate equations to a drug development team is perhaps not the best way to get a message across. Visualization of the consequences of the knowledge encapsulated within the model is the key component. Yet in many instances, it can take hours, perhaps days, to collect ideas from teams, write scripts, and run simulations before presenting the results—by which time they have moved on. How much better, then, to seize the moment and work interactively to decide on a course of action, guided by the model. We exemplify here the visualization of pharmacometric models using the Berkeley Madonna software with a particular focus on interactive sessions. The examples are provided as Supplementary Material. PMID:24872204

  7. Cyclotron resonance cooling by strong laser field

    SciTech Connect

    Tagcuhi, Toshihiro; Mima, Kunioka

    1995-12-31

    Reduction of energy spread of electron beam is very important to increase a total output radiation power in free electron lasers. Although several cooling systems of particle beams such as a stochastic cooling are successfully operated in the accelerator physics, these cooling mechanisms are very slow and they are only applicable to high energy charged particle beams of ring accelerators. We propose here a new concept of laser cooling system by means of cyclotron resonance. Electrons being in cyclotron motion under a strong magnetic field can resonate with circular polarized electromagnetic field, and the resonance take place selectively depending on the velocity of the electrons. If cyclotron frequency of electrons is equal to the frequency of the electromagnetic field, they absorb the electromagnetic field energy strongly, but the other electrons remain unchanged. The absorbed energy will be converted to transverse kinetic energy, and the energy will be dumped into the radiation energy through bremastrahlung. To build a cooling system, we must use two laser beams, where one of them is counter-propagating and the other is co-propagating with electron beam. When the frequency of the counter-propagating laser is tuned with the cyclotron frequency of fast electrons and the co-propagating laser is tuned with the cyclotron frequency of slow electrons, the energy of two groups will approach and the cooling will be achieved. We solve relativistic motions of electrons with relativistic radiation dumping force, and estimate the cooling rate of this mechanism. We will report optimum parameters for the electron beam cooling system for free electron lasers.

  8. Development of an Accelerator Mass Spectrometer based on a Cyclotron

    SciTech Connect

    Kim, Dogyun; Bhang, Hyeongchan; Kim, Jongwon

    2011-12-13

    An accelerator mass spectrometer based on a cyclotron has been developed, and a prototype of the injection beam line has been constructed. Mass resolution of the cyclotron is designed to be over 4000. A sawtooth RF buncher in the beam line and a flat-topping RF system for the cyclotron were utilized to enhance beam transmission efficiency, which is a primary factor for improvement compared to previous cyclotron mass spectrometers. The injection beam line comprises an ion source, Einzel lens, RF buncher, 90 deg. dipole magnet and a slit box containing beam diagnostic devices. A carbon beam was measured at the location of the slit box, and beam phase spaces will be measured. The design of a cyclotron magnet was done, and orbit tracking was carried out using cyclotron optics codes. A scheme of radial injection was chosen to place a beam on the equilibrium orbit of the cyclotron. The injection scheme will be optimized after the beam measurements are completed.

  9. Guidelines for the segregation characterization management of dry waste at Berkeley Lab

    SciTech Connect

    1997-05-01

    Managing and disposing of dry low level radioactive waste at Berkeley Lab. is problematic. The Waste Management Group must assure off site treatment, storage, and disposal facilities that dry waste from Berkeley Lab. is free of liquids and regulated metals (such as lead and mercury). RTR (Real Time Radioagraphy) used for waste to be rejected. This pamphlet helps to clarify dry waste management requirements that will ensure that Berkeley Lab. dry waste will be accepted for off site shipment. These issues are critical if we are to have an off site disposal option for your dry radioactive waste.

  10. Phase-resolved cyclotron spectroscopy of polars

    NASA Astrophysics Data System (ADS)

    Campbell, Ryan

    In this thesis we use phase-resolved cyclotron spectroscopy to study polars. Polars are a subset of cataclysmic variables where the primary WD is highly magnetic. In this case, the accretion flow is constrained along the magnetic field lines and eventually deposited on the WD, where the accreting material interacts with the atmosphere, forming a standing hydrodynamic shock at a location termed the accretion region, and emitting cyclotron radiation. Due to its field strength, cyclotron radiation from polars falls at either UV, optical or NIR wavelengths. While a substantial amount of optical cyclotron spectra have been published on polars, the NIR remains relatively unstudied. In this thesis, we present NIR spectroscopy for fifteen polars. Additionally, while a single cyclotron spectrum is needed to constrain the shock parameters, phase- resolved spectroscopy allows for a more in-depth analysis of the shock structure and the geometry of the accretion region. Of the fifteen polars observed, eight yielded spectra of adequate quality to be modeled in this manner: EF Eri, EQ Cet, AN UMa, VV Pup, AM Her, ST LMi, MR Ser, and MQ Dra. Initially, we used the industry standard "Constant Lambda (CL)" code to model each object. The code is fast, but produces only globally averaged values of the salient shock parameters: B - the magnetic field strength, kT - the plasma temperature, logL - the "size parameter" of the accretion column, and TH- the viewing angle between the observer and the magnetic field. For each object we present CL models for our NIR phase-resolved cyclotron spectra. Subsequently, we use a more advanced "Structured-Shock" code built by Fischer & Beuermann (2001)("F&B") to remodel three objects: EQ Cet, MQ Dra, and EF Eri. The F&B code allows for input of more physical parameters and most importantly does ray tracing through a simulated one-dimensional accretion column. To determine the outgoing spectrum, temperature and velocity profiles are needed to

  11. Berkeley SuperNova Ia Program (BSNIP): Initial Spectral Analysis

    NASA Astrophysics Data System (ADS)

    Silverman, Jeffrey; Kong, J.; Ganeshalingam, M.; Li, W.; Filippenko, A. V.

    2011-01-01

    The Berkeley SuperNova Ia Program (BSNIP) has been observing nearby (z < 0.1) Type Ia supernovae (SNe Ia) both photometrically and spectroscopically for over two decades. Using telescopes at both Lick and Keck Observatories, we have amassed an extensive collection of well-sampled optical light curves with complementary spectra covering, on average, 3400-10,000 Å. In total, we have obtained nearly 600 spectra of over 200 SNe Ia with densely sampled multi-color light curves. The initial analysis of this dataset consists of accurately and robustly measuring the strength and position of various spectral features near maximum brightness. We determine the endpoints, pseudo-continuum, expansion velocity, equivalent width, and depth of each major feature observed in our wavelength range. For objects with multiple spectra near maximum brightness we investigate how these values change with time. From these measurements we also calculate velocity gradients and various flux ratios within a given spectrum which will allow us to explore correlations between spectral and photometric observables. Some possible correlations have been studied previously, but our dataset is unique in how self-consistent the data reduction and spectral feature measurements have been, and it is a factor of a few larger than most earlier studies. We will briefly summarize the contents of the full dataset as an introduction to our initial analysis. Some of our measurements of SN Ia spectral features, along with a few initial results from those measurements, will be presented. Finally, we will comment on our current progress and planned future work. We gratefully acknowledge the financial support of NSF grant AST-0908886, the TABASGO Foundation, and the Marc J. Staley Graduate Fellowship in Astronomy.

  12. Lawrence Berkeley Laboratory Institutional Plan, FY 1993--1998

    SciTech Connect

    Not Available

    1992-10-01

    The FY 1993--1998 Institutional Plan provides an overview of the Lawrence Berkeley Laboratory mission, strategic plan, scientific initiatives, research programs, environment and safety program plans, educational and technology transfer efforts, human resources, and facilities needs. The Strategic Plan section identifies long-range conditions that can influence the Laboratory, potential research trends, and several management implications. The Initiatives section identifies potential new research programs that represent major long-term opportunities for the Laboratory and the resources required for their implementation. The Scientific and Technical Programs section summarizes current programs and potential changes in research program activity. The Environment, Safety, and Health section describes the management systems and programs underway at the Laboratory to protect the environment, the public, and the employees. The Technology Transfer and Education programs section describes current and planned programs to enhance the nation's scientific literacy and human infrastructure and to improve economic competitiveness. The Human Resources section identifies LBL staff composition and development programs. The section on Site and Facilities discusses resources required to sustain and improve the physical plant and its equipment. The Resource Projections are estimates of required budgetary authority for the Laboratory's ongoing research programs. The plan is an institutional management report for integration with the Department of Energy's strategic planning activities that is developed through an annual planning process. The plan identifies technical and administrative directions in the context of the National Energy Strategy and the Department of Energy's program planning initiatives. Preparation of the plan is coordinated by the Office for Planning and Development from information contributed by the Laboratory's scientific and support divisions.

  13. Lawrence Berkeley Laboratory Institutional Plan, FY 1993--1998

    SciTech Connect

    Chew, Joseph T.; Stroh, Suzanne C.; Maio, Linda R.; Olson, Karl R.; Grether, Donald F.; Clary, Mary M.; Smith, Brian M.; Stevens, David F.; Ross, Loren; Alper, Mark D.; Dairiki, Janis M.; Fong, Pauline L.; Bartholomew, James C.

    1992-10-01

    The FY 1993--1998 Institutional Plan provides an overview of the Lawrence Berkeley Laboratory mission, strategic plan, scientific initiatives, research programs, environment and safety program plans, educational and technology transfer efforts, human resources, and facilities needs. The Strategic Plan section identifies long-range conditions that can influence the Laboratory, potential research trends, and several management implications. The Initiatives section identifies potential new research programs that represent major long-term opportunities for the Laboratory and the resources required for their implementation. The Scientific and Technical Programs section summarizes current programs and potential changes in research program activity. The Environment, Safety, and Health section describes the management systems and programs underway at the Laboratory to protect the environment, the public, and the employees. The Technology Transfer and Education programs section describes current and planned programs to enhance the nation`s scientific literacy and human infrastructure and to improve economic competitiveness. The Human Resources section identifies LBL staff composition and development programs. The section on Site and Facilities discusses resources required to sustain and improve the physical plant and its equipment. The Resource Projections are estimates of required budgetary authority for the Laboratory`s ongoing research programs. The plan is an institutional management report for integration with the Department of Energy`s strategic planning activities that is developed through an annual planning process. The plan identifies technical and administrative directions in the context of the National Energy Strategy and the Department of Energy`s program planning initiatives. Preparation of the plan is coordinated by the Office for Planning and Development from information contributed by the Laboratory`s scientific and support divisions.

  14. Seismic Landslide Hazard for the City of Berkeley, California

    USGS Publications Warehouse

    Miles, Scott B.; Keefer, David K.

    2001-01-01

    This map describes the possible hazard from earthquake-induced landslides for the city of Berkeley, CA. The hazard depicted by this map was modeled for a scenario corresponding to an M=7.1 earthquake on the Hayward, CA fault. This scenario magnitude is associated with complete rupture of the northern and southern segments of the Hayward fault, an event that has an estimated return period of about 500 years. The modeled hazard also corresponds to completely saturated ground-water conditions resulting from an extreme storm event or series of storm events. This combination of earthquake and ground-water scenarios represents a particularly severe state of hazard for earthquake-induced landslides. For dry ground-water conditions, overall hazard will be less, while relative patterns of hazard are likely to change. Purpose: The map is intended as a tool for regional planning. Any site-specific planning or analysis should be undertaken with the assistance of a qualified geotechnical engineer. This hazard map should not be used as a substitute to the State of California Seismic Hazard Zones map for the same area. (See California Department of Conservation, Division of Mines and Geology, 1999). As previously noted for maps of this type by Wieczorek and others (1985), this map should not be used as a basis to determine the absolute risk from seismically triggered landslides at any locality, as the sole justification for zoning or rezoning any parcel, for detailed design of any lifeline, for site-specific hazard-reduction planning, or for setting or modifying insurance rates.

  15. Lawrence Berkeley Laboratory, Institutional Plan FY 1994--1999

    SciTech Connect

    Not Available

    1993-09-01

    The Institutional Plan provides an overview of the Lawrence Berkeley Laboratory mission, strategic plan, scientific initiatives, research programs, environment and safety program plans, educational and technology transfer efforts, human resources, and facilities needs. For FY 1994-1999 the Institutional Plan reflects significant revisions based on the Laboratory`s strategic planning process. The Strategic Plan section identifies long-range conditions that will influence the Laboratory, as well as potential research trends and management implications. The Initiatives section identifies potential new research programs that represent major long-term opportunities for the Laboratory, and the resources required for their implementation. The Scientific and Technical Programs section summarizes current programs and potential changes in research program activity. The Environment, Safety, and Health section describes the management systems and programs underway at the Laboratory to protect the environment, the public, and the employees. The Technology Transfer and Education programs section describes current and planned programs to enhance the nation`s scientific literacy and human infrastructure and to improve economic competitiveness. The Human Resources section identifies LBL staff diversity and development program. The section on Site and Facilities discusses resources required to sustain and improve the physical plant and its equipment. The new section on Information Resources reflects the importance of computing and communication resources to the Laboratory. The Resource Projections are estimates of required budgetary authority for the Laboratory`s ongoing research programs. The Institutional Plan is a management report for integration with the Department of Energy`s strategic planning activities, developed through an annual planning process.

  16. Survey and Alighment for the ALS Project at LBL Berkeley

    SciTech Connect

    Keller, R.; Lauritzen, T.; Friedsam, H.; /SLAC

    2005-08-12

    The Advanced Light Source (ALS), now under construction at Lawrence Berkeley Laboratory, is a synchrotron radiation source of the third generation designed to produce extremely bright photon beams in the UV and soft X-ray regions. Its main accelerator components are a 1-1.9 GeV electron storage ring with 196.8 m circumference and 12 super-periods, a 1.5 GeV booster synchrotron with 75.0 m circumference and 4 super-periods, and a 50 MeV linac, as shown in Fig. 1. The storage ring has particularly tight positioning tolerances for lattice magnets and other components to assure the required operational characteristics. The general survey and alignment concept for the ALS is based on a network of fixed monuments installed in the building floor, to which all component positions are referred. Measurements include electronic distance measurements and separate sightings for horizontal and vertical directions, partially with automated electronic data capture. Most of the data processing is accomplished by running a customized version of PC-GEONET. It provides raw data storage, data reduction, and the calculation of adjusted coordinates, as well as an option for error analysis. PC-GEONET has also been used to establish an observation plan for the monuments and calculate their expected position accuracies, based on approximate coordinates. Additionally, for local survey tasks, the commercial software package ECDS is used. In this paper, the ALS survey and alignment strategy and techniques are presented and critically discussed. First experiences with the alignment of the linac and booster components are described.

  17. An organizational cultural assessment of Lawrence Berkeley Laboratory

    SciTech Connect

    Haber, S.B.; Crouch, D.A.

    1991-02-15

    An Organizational Cultural Assessment (OCA) was performed at the Lawrence Berkeley Laboratory (LBL) by administering an Organizational Culture Survey (OCS) that queried employees on the subjects of organizational culture, various aspects of communications employee commitment, work group cohesion, coordination of work, environmental concerns, hazardous nature of work, safety and overall job satisfaction. Many of these subjects are assessed in the OCS through highly developed and validated scales that have been administered in many different types of organizations. Some of the issues, especially the questions on environmental concerns, are newly developed and are still being modified. The purpose of the OCS is to measure in a quantitative and objective way the notion of culture;'' that is, the values, attitudes and beliefs of the individuals working within the organization. In addition, through the OCS, a broad sample of individuals can be reached that would probably not be interviewed or observed during the course of a typical assessment. The OCS also provides a descriptive profile of the organization at one point in time that can than be compared to a profile taken at a different point in time to assess changes in the culture of the organization. All data from the OCS is presented in group summaries, by division, managerial level, and job classification. Statistically significant differences between groups are identified and discussed. The organizational profile which emerges from the results of the LBL samples is a positive one. The overall cultural style is best described as a constructive one, with high mean scores on the Humanistic, Affiliative, Achievement and Self-actualizing Scales. Four aspects to the communication process were assessed in this OCS; Trust, Accuracy, Interaction and Satisfaction. 9 refs., 57 figs., 6 tabs.

  18. Early Geologic Education in California--Berkeley and Stanford Show the Way.

    ERIC Educational Resources Information Center

    Norris, Robert M.

    1981-01-01

    Traces the early history of geological education in California universities, with emphasis upon programs at Berkeley and Stanford. Among the pioneers in the field were Joseph LeConte, Andrew C. Lawson, and John C. Branner. (WB)

  19. Laboratories for the 21st Century: Case Studies, Molecular Foundry, Berkeley, California

    SciTech Connect

    Not Available

    2010-11-01

    This case study provides information on the Molecular Foundry, which incorporates Labs21 principles in its design and construction. The design includes many of the strategies researched at Lawrence Berkeley Laboratory for energy efficient cleanroom and data centers.

  20. Ion cyclotron waves observed near the plasmapause

    NASA Technical Reports Server (NTRS)

    Fraser, B. J.; Samson, J. C.; Mcpherron, R. L.; Russell, C. T.

    1986-01-01

    Pc2 electromagnetic ion cyclotron waves at 0.1 Hz, near the oxygen cyclotron frequency, have been observed by ISEE-1 and -2 between L = 7.6 - 5.8 on an inbound near equatorial pass in the dusk sector. The waves occurred in a thick plasmapause of width about 1 earth radius and penetrated about 1 earth radius into the plasmasphere. Wave onset was accompanied by significant increases in the thermal (0-100 eV) He(+) and the warm (0.1-16 keV/e) O(+) and He(+) heavy ion populations. Wave polarization is predominantly left-handed with propagation almost parallel to the ambient magnetic field, and the spectral slot and polarization reversal predicted by multicomponent cold plasma propagation theory are identified in the wave data. The results are considered as an example of wave-particle interactions occurring during the outer plasmasphere refilling process at the time of the substorm recovery phase.

  1. New magnet pole shape for isochronous cyclotrons

    SciTech Connect

    Thorn, C.E.; Chasman, C.; Baltz, A.J.

    1981-01-01

    A new design has been developed for shaping pole tips to produce the radially increasing fields required for isochronous cyclotrons. The conventional solid hill poles are replaced by poles mounted over a small secondary gap which tapers radially from maximum at the magnet edge to zero near the center. Field measurements with a model magnet and calculations with the code TRIM show an increase in field at the edge of the magnet without the usual corresponding large increase in fringing, and a radial field shape more nearly field independent than for conventional hills. The flying hills have several advantages for variable energy multiparticle cyclotrons: (1) a large reduction in the power dissipated by isochronizing trim coils; (2) a more constant shape and magnitude flutter factor, eliminating flutter coils and increasing the operating range; and (3) a sharper fall-off of the fringe field, simplifying beam extraction.

  2. New magnet pole shape for isochronous cyclotrons

    SciTech Connect

    Thorn, C.E.; Chasman, C.; Baltz, A.J.

    1981-06-01

    A new design has been developed for shaping pole tips to produce the radially increasing fields required for isochronous cyclotrons. The conventional solid hillpoles are replaced by poles mounted over a small secondary gap which tapers radially from maximum at the magnet edge to zero near the center. Field measurements with a model magnet and calculations with the code TRIM show an increase in field at the edge of the magnet without the usual corresponding large increase in fringing, and a radial field shape more nearly field independent than for conventional hills. The flying hills have several advantages for variable energy multiparticle cyclotrons: (1) a large reduction in the power dissipated by isochronizing trim coils; (2) a more constant shape and magnitude flutter factor, eliminating flutter coils and increasing the operating range; and (3) a sharper fall-off of the fringe field, simplifying beam extraction. 6 figures.

  3. Xe/+/ -induced ion-cyclotron harmonic waves

    NASA Astrophysics Data System (ADS)

    Jones, D.

    Xenon ion sources on an ejectable package separated from the main payload during the flights of Porcupine rockets F3 and F4 which were launched from Kiruna, Sweden on March 19 and 31, 1979, respectively. The effects of the xenon ion beam, detected by the LF (f less than 16 kHz) wideband electric field experiment and analyzed by using a sonograph, are discussed. Particular attention is given to the stimulation of the ion-cyclotron harmonic waves which are usually linked to the local proton gyro-frequency, but are sometimes related to half that frequency. It was found that in a plasma dominated by O(+) ions, a small amount (1-10%) of protons could cause an effect such that the O(+) cyclotron harmonic waves are set up by the hydrogen ions, the net result being the observation of harmonic emissions separated by the hydrogen ion gyro frequency.

  4. The mirror and ion cyclotron anisotropy instabilities

    NASA Technical Reports Server (NTRS)

    Gary, S. P.

    1992-01-01

    The linear dispersion equation for fully electromagnetic waves and instabilities at arbitrary directions of propagation relative to a background magnetic field B(0) in a homogeneous Vlasov plasma is solved numerically for bi-Maxwellian particle distributions. For isotropic plasmas the dispersion and damping of the three modes below the proton cyclotron frequency are studied as functions of Beta(i) and T(e)/T(i). The transport ratios of helicity, cross-helicity, Alfven ratio, compressibility, and parallel compressibility are defined. Under the condition that the proton temperature perpendicular to B(0) is greater than the parallel temperature, the growth rates and transport ratios of the mirror instability and the ion cyclotron anisotropy instability are examined and compared. Both the proton parallel compressibility and the proton Alfven ratio are significantly different for the two growing modes.

  5. Electrostatic ion cyclotron velocity shear instability

    NASA Technical Reports Server (NTRS)

    Lemons, D. S.; Winske, D.; Gary, S. P.

    1992-01-01

    A local electrostatic dispersion equation is derived for a shear flow perpendicular to an ambient magnetic field, which includes all kinetic effects and involves only one important parameter. The dispersion equation is cast in the form of Gordeyev integrals and is solved numerically. Numerical solutions indicate that an ion cyclotron instability is excited. The instability occurs roughly at multiples of the ion cyclotron frequency (modified by the shear), with the growth rate or the individual harmonics overlapping in the wavenumber. At large values of the shear parameter, the instability is confined to long wavelengths, but at smaller shear, a second distinct branch at shorter wavelengths also appears. The properties of the instability obtained are compared with those obtained in the nonlocal limit by Ganguli et al. (1985, 1988).

  6. Orbit correction in an orbit separated cyclotron

    NASA Astrophysics Data System (ADS)

    Plostinar, C.; Rees, G. H.

    2014-04-01

    The orbit separated proton cyclotron (OSC) described in [1] differs in concept from that of a separated orbit cyclotron (SOC) [2]. Synchronous acceleration in an OSC is based on harmonic number jumps and orbit length adjustments via reverse bending. Four-turn acceleration in the OSC enables it to have four times fewer cryogenic-cavity systems than in a superconducting linac of the same high beam power and energy range. Initial OSC studies identified a progressive distortion of the spiral beam orbits by the off-axis, transverse deflecting fields in its accelerating cavities. Compensation of the effects of these fields involves the repeated use of a cavity field map, in a 3-D linac tracking code, to determine the modified arc bends required for the OSC ring. Subsequent tracking studies confirm the compensation scheme and show low emittance growth in acceleration.

  7. Cyclotron emission from nonuniformly magnetized plasmas

    SciTech Connect

    Swanson, D.G.; Shvets, V.F. )

    1992-05-18

    A new quantitative representation of the generalized Kirchhoff's law relating the emission from each propagating branch to the absorption along the corresponding branch is established, including for the first time the effects of inhomogeneous magnetic fields on cyclotron and synchrotron radiation from mode conversion theory. The concept of optical depth is revised to include effects of reflection and conversion in addition to transmission. Via the use of a variational principle, the source distribution function for the inhomogeneous emitting layer is calculated.

  8. Transparency of Magnetized Plasma at Cyclotron Frequency

    SciTech Connect

    G. Shvets; J.S. Wurtele

    2002-03-14

    Electromagnetic radiation is strongly absorbed by a magnetized plasma if the radiation frequency equals the cyclotron frequency of plasma electrons. It is demonstrated that absorption can be completely canceled in the presence of a magnetostatic field of an undulator or a second radiation beam, resulting in plasma transparency at the cyclotron frequency. This effect is reminiscent of the electromagnetically induced transparency (EIT) of the three-level atomic systems, except that it occurs in a completely classical plasma. Unlike the atomic systems, where all the excited levels required for EIT exist in each atom, this classical EIT requires the excitation of the nonlocal plasma oscillation. The complexity of the plasma system results in an index of refraction at the cyclotron frequency that differs from unity. Lagrangian description was used to elucidate the physics and enable numerical simulation of the plasma transparency and control of group and phase velocity. This control naturally leads to applications for electromagnetic pulse compression in the plasma and electron/ion acceleration.

  9. ITER Ion Cyclotron Heating and Fueling Systems

    SciTech Connect

    Rasmussen, D.A.; Baylor, L.R.; Combs, S.K.; Fredd, E.; Goulding, R.H.; Hosea, J.; Swain, D.W.

    2005-04-15

    The ITER burning plasma and advanced operating regimes require robust and reliable heating and current drive and fueling systems. The ITER design documents describe the requirements and reference designs for the ion cyclotron and pellet fueling systems. Development and testing programs are required to optimize, validate and qualify these systems for installation on ITER.The ITER ion cyclotron system offers significant technology challenges. The antenna must operate in a nuclear environment and withstand heat loads and disruption forces beyond present-day designs. It must operate for long pulse lengths and be highly reliable, delivering power to a plasma load with properties that will change throughout the discharge. The ITER ion cyclotron system consists of one eight-strap antenna, eight rf sources (20 MW, 35-65 MHz), associated high-voltage DC power supplies, transmission lines and matching and decoupling components.The ITER fueling system consists of a gas injection system and multiple pellet injectors for edge fueling and deep core fueling. Pellet injection will be the primary ITER fuel delivery system. The fueling requirements will require significant extensions in pellet injector pulse length ({approx}3000 s), throughput (400 torr-L/s,) and reliability. The proposed design is based on a centrifuge accelerator fed by a continuous screw extruder. Inner wall pellet injection with the use of curved guide tubes will be utilized for deep fueling.

  10. Laboratory study of auroral cyclotron emission processes

    NASA Astrophysics Data System (ADS)

    Ronald, Kevin

    2007-11-01

    Electrons encounter an increasing magnetic field and increase in pitch angle as they descend towards the auroral ionosphere, according to the conservation of the magnetic moment. This process results in a horseshoe shaped distribution function in electron velocity space which has been observed by satellites [1]. Research has shown this distribution to be unstable to a cyclotron maser instability [2] and the emitted Auroral Kilometric Radiation is observed to be polarised in the extraordinary mode. Experimental results are presented based on an electron beam of energy 75keV having a cyclotron frequency of 4.45GHz, compressed using magnet coils to mimic the naturally occurring phenomenon. The emitted radiation spectrum was observed to be close to the cyclotron frequency. Electron transport measurements confirmed that the horseshoe distribution function was obtained. Measurements of the antenna pattern radiated from the output window demonstrated the radiation to be polarised and propagating perpendicular to the static magnetic field. The radiation generation efficiency was estimated to be 2% in close agreement to the numerical predictions of the 2D PiC code KARAT. The efficiency was also comparable with estimates of the astrophysical phenomenon. [1] R. J. Strangeway et al, Geophys. Rev. Lett., 25, 1998, pp. 2065-2068 [2] I Vorgul et al, Physics of Plasmas, 12, 2005, pp. 1-8

  11. Improving cancer treatment with cyclotron produced radionuclides

    SciTech Connect

    Larson, S.M.; Finn, R.D.

    1992-08-04

    Our goal is to improve the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. The radiochemistry group seeks to develop innovative cyclotron targetry, radiopharmaceuticals, and radiolabeled antibodies, which are then used to assess important unanswered questions in tumor pharmacology and immunology. Examples include selected positron emitting radionuclides, such as Iodine-124, and Ga-66; I-124, I-123, I-131 labeled iododeoxyuridine, C-11 colchicine, and antimetabolites, like C-11 methotrexate; and radiolabeled antibodies, 3F8, M195, A33, and MRK16 for application in the pharmacology and immunology projects. The pharmacology program studies tumor resistance to chemotherapy, particularly the phenomenon of multidrug resistance and the relationship between tumor uptake and retention and the tumor response for anti-metabolite drugs. The immunology program studies the physiology of antibody localization at the tissue level as the basis for novel approaches to improving tumor localization such as through the use of an artificial lymphatic system which mechanically reduces intratumoral pressures in tumors in vivo. Quantitative imaging approaches based on PET and SPECT in radioimmunotherapy are studied to give greater insight into the physiology of tumor localization and dosimetry.

  12. Simulations of ion cyclotron anisotropy instabilities in the terrestrial magnetosheath

    NASA Technical Reports Server (NTRS)

    Gary, S. P.; Winske, Dan

    1993-01-01

    Enhanced transverse magnetic fluctuations observed below the proton cyclotron frequency in the terrestrial magnetosheath have been identified as due to the proton cyclotron and helium cyclotron instabilities driven by the T-perpendicular greater than T-parallel condition of the sheath ions. One-dimensional hybrid computer simulations are used here to examine the nonlinear properties of these two growing modes at relatively weak fluctuation energies and for wave vectors parallel to the background magnetic field. Second-order theory predicts fluctuating magnetic field energies at saturation of the proton cyclotron anisotropy instability in semiquantitative agreement with the simulation results. Introduction of the helium component enhances the wave-particle exchange rate for proton anisotropy reduction by that instability, thereby reducing the saturation energy of that mode. The simulations demonstrate that wave-particle interactions by the proton cyclotron and helium cyclotron instabilities lead to the anticorrelation observed by Anderson and Fuselier (1993).

  13. Lawrence Berkeley Laboratory Institutional Plan FY 1987-1992

    SciTech Connect

    Various

    1986-12-01

    The Lawrence Berkeley Laboratory, operated by the University of California for the Department of Energy, provides national scientific leadership and supports technological innovation through its mission to: (1) Perform leading multidisciplinary research in general sciences and energy sciences; (2) Develop and operate unique national experimental facilities for use by qualified investigators; (3) Educate and train future generations of scientists and engineers; and (4) Foster productive relationships between LBL research programs and industry. The following areas of research excellence implement this mission and provide current focus for achieving DOE goals. GENERAL SCIENCES--(1) Accelerator and Fusion Research--accelerator design and operation, advanced accelerator technology development, accelerator and ion source research for heavy-ion fusion and magnetic fusion, and x-ray optics; (2) Nuclear Science--relativistic heavy-ion physics, medium- and low-energy nuclear physics, nuclear theory, nuclear astrophysics, nuclear chemistry, transuranium elements studies, nuclear data evaluation, and detector development; (3) Physics--experimental and theoretical particle physics, detector development, astrophysics, and applied mathematics. ENERGY SCIENCES--(1) Applied Science--building energy efficiency, solar for building systems, fossil energy conversion, energy storage, and atmospheric effects of combustion; (2) Biology and Medicine--molecular and cellular biology, diagnostic imaging, radiation biophysics, therapy and radiosurgery, mutagenesis and carcinogenesis, lipoproteins, cardiovascular disease, and hemopoiesis research; (3) Center for Advanced Materials--catalysts, electronic materials, ceramic and metal interfaces, polymer research, instrumentation, and metallic alloys; (4) Chemical Biodynamics--molecular biology of nucleic acids and proteins, genetics of photosynthesis, and photochemistry; (5) Earth Sciences--continental lithosphere properties, structures and

  14. Circumsolar Radiation Data: The Lawrence Berkeley Laboratory Reduced Data Base

    DOE Data Explorer

    The Lawrence Berkeley Laboratory Reduced Data Base contains approximately 288 megabytes of information, including detailed intensity profiles of the solar and circumsolar region, the total and spectrally divided direct normal radiation data, as well as the total hemispherical solar radiation in the horizontal plane and the plane facing the sun. Data are available for 11 locations in the United States in the period 1976 to 1981. The measurements were made by four circumsolar telescopes operating about 16 hours per day. The Reduced Data Base represents about one-tenth of the total data taken by the circumsolar telescopes. The sites, the amount of data available for each site, and the collection dates are: • Albuquerque (STTF), New Mexico (28,971 data sets from 4/77 to 10/79 • Albuquerque (TETF), New Mexico (13,851 data sets from 5/76 to 3/77) • Argonne, Illinois (9,702 data sets from 8/77 to 8/78) • Atlanta, Georgia (38,405 data sets from 6/77 to 6/80) • Barstow, California (36,632 data sets from 7/77 to 10/79) • Boardman, Oregon (4,782 data sets from 2/77 to 5/77) • China Lake, California (10,683 data sets from 7/76 to 3/77) • Colstrip, Montana (616 data sets from 5/77 to 6/77) • Edwards Air Force Base, California (27,344 data sets from 10/79 to 6/81) • Fort Hood (Bunker), Texas (5,150 data sets from 7/76 to 11/76) • Fort Hood (TES), Texas (8,250 data sets from 11/76 to 8/77) Note that each data set is composed of 20 lines of information with each line consistingof 77 characters. These are archived ASCII files. [Information on sites, number of data sets, etc. taken from the online publication (out of print) at http://rredc.nrel.gov/solar/pubs/circumsolar/index.html

  15. Collecting and Using Low Latency Data at Berkeley Seismological Laboratory

    NASA Astrophysics Data System (ADS)

    Houlié, N.; Allen, R.; Hellweg, P.; Dreger, D.; Neuhauser, D.; Romanowicz, B.

    2008-12-01

    Northern California and the San Francisco Bay Area are among the US regions that combine high earthquake hazard and high population density. To rapidly and reliably monitor tectonic movement and develop an understanding of fault dynamics, measurements must cover a range of scales in time (0.1 s to years), space (mms to 100s of km) and displacement (microns to 10s of m). With these goals in mind, Berkeley Seismological Laboratory (BSL) continuously collects a wide variety of data at low latencies from seismic through geodetic, strain and electromagnetic instrumentation with sampling rates spanning 0.001 sps to 500 sps. Data from broadband seismometers and accelerometers, generally with latencies of less than 10 s, contribute to real time earthquake monitoring in Northern California including rapid assessments of source (moment tensor and finite fault) and shaking (ShakeMap). The BSL is also currently operating a real time system in test mode, using these data for earthquake early warning (ElarmS). Data from these instruments are also used for research on earthquake sources and scaling, fault-related tremor and studies of local, regional and global velocity structure. Low latency GPS data can complement seismic data, contributing robust real time continuous information especially for large earthquakes, and can potentially contribute to early warning. GPS-derived static deformation gives an independent estimate of fault orientation and dimensions, scalar seismic moment and magnitude. It also can extend the upper limits of a strong motion network to include the displacements of tens of meters expected in large and great earthquakes, and in the near field is less likely to be clipped during large movements. In an active tectonic context such as Northern California, low latency is important for data transmission, but also for reliability. At the BSL we are committed to using telemetry that is as robust as possible and often have more than one telemetry path to ensure

  16. Status of the UC-Berkeley SETI efforts

    NASA Astrophysics Data System (ADS)

    Korpela, E. J.; Anderson, D. P.; Bankay, R.; Cobb, J.; Howard, A.; Lebofsky, M.; Siemion, A. P. V.; von Korff, J.; Werthimer, D.

    2011-10-01

    We summarize radio and optical SETI programs based at the University of California, Berkeley. The SEVENDIP optical pulse search looks for ns time scale pulses at visible wavelengths. It utilizes an automated 30 inch telescope, three ultra fast photo multiplier tubes and a coincidence detector. The target list includes F, G, K and M stars, globular cluster and galaxies. The ongoing SERENDIP V.v sky survey searches for radio signals at the 300 meter Arecibo Observatory. The currently installed configuration supports 128 million channels over a 200 MHz bandwidth with ~1.6 Hz spectral resolution. Frequency stepping allows the spectrometer to cover the full 300MHz band of the Arecibo L-band receivers. The final configuration will allow data from all 14 receivers in the Arecibo L-band Focal Array to be monitored simultaneously with over 1.8 billion channels. SETI@home uses the desktop computers of volunteers to analyze over 160 TB of data at taken at Arecibo. Over 6 million volunteers have run SETI@home during its 10 year history. The SETI@home sky survey is 10 times more sensitive than SERENDIP V.v but it covers only a 2.5 MHz band, centered on 1420 MHz. SETI@home searches a much wider parameter space, including 14 octaves of signal bandwidth and 15 octaves of pulse period with Doppler drift corrections from -100 Hz/s to +100 Hz/s. SETI@home is being expanded to analyze data collected during observations of Kepler objects of interest in May 2011. The Astropulse project is the first SETI search for μs time scale pulses in the radio spectrum. Because short pulses are dispersed by the interstellar medium, and the amount of dispersion is unknown, Astropulse must search through 30,000 possible dispersions. Substantial computing power is required to conduct this search, so the project uses volunteers and their personal computers to carry out the computation (using distributed computing similar to SETI@home). Keywords: radio instrumentation, FPGA spectrometers, SETI, optical

  17. SETI Programs at the University of California, Berkeley

    NASA Astrophysics Data System (ADS)

    Korpela, E. J.; Siemion, A. V. P.; Werthimer, D.; Korff, J. V.; Gautham, A.; Cobb, J.; Lebofsky, M.; Dexter, M.; MacMahon, D.; Wright, S.

    2014-03-01

    I describe recent SETI efforts by the University of California, Berkeley SETI Research center and efforts to be undertaken in the near future. In addition to our well known SETI@home (Korpela 2011) and Astropulse (Von Korff et al. 2013) public participation SETI survey projects, we have performed several targeted obsevations of different object classes. These include 1) Observations between 1.1 and 1.9 GHz of planetary systems idenfied by Kepler as containing earthlike planets in or near the habitable zones. (Siemion et al. 2013) 2) Wide-band Arecibo observations of 112 sky locations where the Astropulse project has identified strong µs duration dispersed radio pulses. 3) Observations of Kepler identified planetary systems at times when two planets would appear to be in conjuction when viewed from Earth. We plan a future campaign to simultaneously observe known planetary systems at radio, optical and IR wavelengths. We have also continued to advance our instrumentation. We are currently building the sixth generation of our SERENDIP (Siemion et al. 2011, Korpela et al. 2011) series of SETI instrumentation for installation at both Arecibo and GBT. SERENDIP VI will utilize an FPGA based polyphase filter bank course spectrometer feeding 8 or more GPU based compute nodes. The Arecibo version of this spectrometer will be capable of providing thresholded 1Hz resolution spectra of all seven beams of the 320 MHz bandwidth Arecibo L-band Feed Array in dual polarization. A separate front end will be available to allow up to 2.2 GHz of bandwidth in dual polarization from single pixel receivers. The Green Bank version of this spectrometer will utilize the single pixel front end. We are invesitating the possibility of simultaneous back end stages operating on the same or minimal processed data, for example, we could support simulataneous detection of fast extragalactic radio bursts (Thornton et al. 2013) by adding additional compute nodes. We are also developing new instruments

  18. Current driven electrostatic and electromagnetic ion cyclotron instabilities

    NASA Technical Reports Server (NTRS)

    Forslund, D. W.; Kennel, C. F.; Kindel, J. M.

    1971-01-01

    Growth rates and parameter dependences are calculated for the current driven instabilities of electrostatic (with finite-beta corrections) and electromagnetic ion cyclotron waves. For 0.25 (T sub e)/(T sub i) 2.5, ion cyclotron waves have large growth rates, while ion acoustic waves are still stable. In fusion devices, where electrostatic waves may be stable, electromagnetic ion cyclotron waves are unstable for beta sub i 0.001.

  19. Suppression of cyclotron instability in Electron Cyclotron Resonance ion sources by two-frequency heating

    SciTech Connect

    Skalyga, V.; Izotov, I.; Mansfeld, D.; Kalvas, T.; Koivisto, H.; Komppula, J.; Kronholm, R.; Laulainen, J.; Tarvainen, O.

    2015-08-15

    Multiple frequency heating is one of the most effective techniques to improve the performance of Electron Cyclotron Resonance (ECR) ion sources. The method increases the beam current and average charge state of the extracted ions and enhances the temporal stability of the ion beams. It is demonstrated in this paper that the stabilizing effect of two-frequency heating is connected with the suppression of electron cyclotron instability. Experimental data show that the interaction between the secondary microwave radiation and the hot electron component of ECR ion source plasmas plays a crucial role in mitigation of the instabilities.

  20. The Michigan State University Cyclotron Laboratory: Its Early Years

    NASA Astrophysics Data System (ADS)

    Austin, Sam M.

    2016-01-01

    The Michigan State University Cyclotron Laboratory was founded in 1958 and over the years grew in stature, becoming the highest-ranked university-based program in nuclear science. Its K50 cyclotron had unmatched capability as a light-ion accelerator and helped to define what a modern cyclotron could do to advance our understanding of nuclei. This paper describes the first twenty years of the Cyclotron Laboratory's evolution and gives some insight into the cultural characteristics of the laboratory, and of its early members, that led it to thrive.

  1. The Lawrence Berkeley National Laboratory ES&H self-assessmentprogram

    SciTech Connect

    Chernowski, John G.

    2003-02-11

    Lawrence Berkeley National Laboratory (Berkeley Lab) is a multiprogram national research facility operated by the University of California for the U.S. Department of Energy (DOE). DOE environment, safety, and health (ES&H) policy requires that all Berkeley Lab work be performed safely, with minimal adverse impact on the public and the environment. To facilitate safe and responsible work, Berkeley Lab divisions, directorates, and select departments must develop and implement Integrated Safety Management (ISM) plans. Berkeley Lab operates a formal internal ES&H self-assessment process to evaluate ES&H programs and policies and assure that ISM is implemented at all levels of activities and operations. ISM requires that: (1) work is defined, (2) hazards are identified, (3) controls are developed and implemented, (4) work is performed as authorized, and (5) feedback and improvement are continuous. These five ISM core functions are sustained by applying the seven guiding principles of ISM. These are: (1) line management responsibility and accountability for ES&H, (2) clear ES&H roles and responsibilities, (3) competency commensurate with responsibilities, (4) an ongoing balance between safety on the one hand and research and operational priorities on the other, (5) identification of standards and requirements, (6) hazard controls tailored to the work, and (7) operations authorization. Self-assessment at Berkeley Lab is a continuous process of information gathering and evaluation. The goals of the self-assessment program are: (a) Ensure that work activities and operations are done safely and in a manner that maximizes public and environmental protection. (b) Ensure that the five core functions and seven guiding principles of integrated safety management are employed effectively in work planning and performance. (c) Meet regulatory requirements for DOE oversight, self-assessment, and an integrated safety management system. (d) Meet contractual requirements for ES

  2. Neutron Soft Errors in Xilinx FPGAs at Lawrence Berkeley National Laboratory

    SciTech Connect

    George, Jeffrey S.; Koga, Rocky; McMahan, Margaret A.

    2008-07-25

    The LBNL 88-Inch Cyclotron offers broad-spectrum neutrons for single event effects testing. We discuss results from this beamline for neutron soft upsets in Xilinx Virtex-4 and -5 field-programmable-gate-array (FPGA) devices.

  3. Cyclotron Mode Frequency Shifts in Multi-Species Ion Plasmas

    NASA Astrophysics Data System (ADS)

    Affolter, Matthew

    2014-10-01

    Plasmas exhibit a variety of cyclotron modes, which are used in a broad range of devices to manipulate and diagnose charged particles. Here we discuss cyclotron modes in trapped plasmas with a single sign of charge. Collective effects and electric fields shift these cyclotron mode frequencies away from the ``bare'' cyclotron frequencies Ωs ≡ qB /ms c for each species s. These electric fields may arise from applied trap potentials, from space charge including collective effects, and from image charge in the trap walls. We will describe a new laser-thermal cyclotron spectroscopy technique, applied to well-diagnosed pure ion plasmas. This technique enables detailed observations of cos (mθ) surface cyclotron modes with m = 0 , 1, and 2 in near rigid-rotor multi-species ion plasmas. For each species s, we observe cyclotron mode frequency shifts which are dependent on the plasma density through the E × B rotation frequency, and on the charge concentration of species s, in close agreement with recent theory. This includes the novel m = 0 radial ``breathing'' mode, which generates no external electric field except at the plasma ends. These cyclotron frequencies can be used to determine the plasma E × B rotation frequency and the species charge concentrations, in close agreement with our laser diagnostics. Here, this plasma characterization permits a determination of the ``bare'' cyclotron frequencies to an accuracy of 2 parts in 104. These new results give a physical basis for the ``space charge'' and ``amplitude'' calibration equations of cyclotron mass spectroscopy, widely used in molecular chemistry and biology. Also, at high temperatures there is preliminary evidence that radially-standing electrostatic Bernstein waves couple to the surface cyclotron modes, producing new resonant frequencies. Supported by NSF/DOE Partnership grants PHY-0903877 and DE-SC0002451.

  4. Electron cyclotron heating in TMX-Upgrade

    SciTech Connect

    Stallard, B.W.; Hooper, E.B. Jr.

    1981-01-01

    TMX-Upgrade, an improved tandem mirror experiment under construction at LLNL, will use electron cyclotron resonance heating (ECRH) to create thermal barriers and to increase the center cell ion confining potential. Gyrotron oscillators (200 kW, 28 GHz) supply the heating power for the potential confined electron (fundamental heating) and the mirror-confined electrons (harmonic heating) in the thermal barriers. Important issues are temperature limitation and microstability for the hot electrons. Off-midplane heating can control anisotropy-driven microstability. Spacially restricting heating offers the possibility of temperature control by limiting the energy for resonant interaction.

  5. Method of enhancing cyclotron beam intensity

    DOEpatents

    Hudson, Ed D.; Mallory, Merrit L.

    1977-01-01

    When an easily ionized support gas such as xenon is added to the cold cathode in sources of the Oak Ridge Isochronous Cyclotron, large beam enhancements are produced. For example, .sup.20 Ne.sup.7+ is increased from 0.05 enA to 27 enA, and .sup.16 O.sup.5+ intensities in excess of 35 e.mu.A have been extracted for periods up to 30 minutes. Approximately 0.15 cc/min of the easily ionized support gas is supplied to the ion source through a separate gas feed line and the primary gas flow is reduced by about 30%.

  6. Ion Cyclotron Resonance Heating System on EAST

    NASA Astrophysics Data System (ADS)

    Wang, Lei

    2009-08-01

    Ion cyclotron resonance heating (ICRH) system which will provide at least than 10 MW heating power, with a frequency range from 25 MHz to 100 MHz, is being built up for the EAST. The system includes high-power and wide-frequency radio amplifier, transmission line as well as resonant double loop (RDL) antenna. As a part of this system a sub-ICRH system unit with a ultimate output power of 2.5 MW was set up and employed for heating experiment. The maximum of the launched power reached 200 kW in 2008.

  7. Electron cyclotron emission diagnostics on KSTAR tokamak.

    PubMed

    Jeong, S H; Lee, K D; Kogi, Y; Kawahata, K; Nagayama, Y; Mase, A; Kwon, M

    2010-10-01

    A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration. PMID:21033954

  8. Electron cyclotron emission diagnostics on KSTAR tokamak

    SciTech Connect

    Jeong, S. H.; Lee, K. D.; Kwon, M.; Kogi, Y.; Kawahata, K.; Nagayama, Y.; Mase, A.

    2010-10-15

    A new electron cyclotron emission (ECE) diagnostics system was installed for the Second Korea Superconducting Tokamak Advanced Research (KSTAR) campaign. The new ECE system consists of an ECE collecting optics system, an overmode circular corrugated waveguide system, and 48 channel heterodyne radiometer with the frequency range of 110-162 GHz. During the 2 T operation of the KSTAR tokamak, the electron temperatures as well as its radial profiles at the high field side were measured and sawtooth phenomena were also observed. We also discuss the effect of a window on in situ calibration.

  9. The History of Earthquake Engineering at the University of California at Berkeley and Recent Developments of Numerical Methods and Computer Programs at CSI Berkeley

    NASA Astrophysics Data System (ADS)

    Wilson, E. L.

    The purpose of this paper is to summarize, from a personal viewpoint, some research in structural dynamics within the Department of Civil Engineering at the University of California at Berkeley during the period of 1950 to 1990. The second part of the paper is to present a few recently developed numerical algorithms for dynamic analysis that are required in the design of wind, wave and earthquake resistant structures. These algorithms have been incorporated into the SAP 2000 programs (developed by Computers and Structures, Inc. in Berkeley) and have been used in the analysis of hundreds of large structural systems. This most recent research and development work was conducted since the author's retirement in 1991 from teaching at the University.

  10. Development of accelerator mass spectrometer based on a compact cyclotron

    NASA Astrophysics Data System (ADS)

    Kim, J.-W.; Kim, D.-G.

    2011-07-01

    A small cyclotron has been designed for accelerator mass spectrometry, and the injection beam line is constructed as part of prototyping. Mass resolution of the cyclotron is estimated to be around 4000. The design of the cyclotron was performed with orbit-tracking computations using 3D magnetic and electric fields, and beam optics of the injection line was calculated using the codes such as IGUN and TRANSPORT. The radial injection scheme is chosen to place a beam on equilibrium orbit of the cyclotron. The injection line includes an ion source, Einzel lens, rf buncher, 90° dipole magnet, and quadrupole triplet magnet. A carbon beam was extracted from the front part of the injection line. An rf cavity system for the cyclotron was built and tested. A multi channel plates (MCP) detector to measure low-current ion beams was also tested. Design considerations are given to analyzing a few different radioisotopes in form of positive ions as well as negative ions.

  11. Design Studies for an Ultra High Field K80 Cyclotron

    NASA Astrophysics Data System (ADS)

    Schubert, Jeff; Blosser, Henry

    1996-05-01

    We are investigating the use of a wide-bore, 8 T magnet as a component of an ultra high field cyclotron. Such a machine would use the highest magnetic field of any cyclotron, to date. The K80 `Eight Tesla Cyclotron' would have roughly the same magnetic rigidity (Bρ) as the Oak Ridge Isochronous Cyclotron in a package of only one fourth the radius, with a corresponding reduction in cost. This cyclotron could accelerate particles with a charge state Q/A = 1/4 to a final energy of between 5 and 6 MeV/nucleon, the energy range currently being used to study superdeformed, high angular momentum nuclei that result from glancing collisions. Studies thus far have stressed achieving sufficient vertical focusing (ν_z) despite the high magnetic field level. The high field also reduces the space available for central region structures, which complicates early-turn focusing, orbit centering and the design of the spiral inflector.

  12. A new generation of medical cyclotrons for the 90`s

    SciTech Connect

    Milton, B.F.

    1995-08-01

    Cyclotrons continue to be efficient accelerators for use in radio-isotope production. In recent years, developments in accelerator technology have greatly increased the practical beam current in these machines while also improving the overall system reliability. These developments combined with the development of new isotopes for medicine and industry, and a retiring of older machines indicates a strong future for commercial cyclotrons. In this paper the authors will survey recent developments in the areas of cyclotron technology as they relate to the new generation of commercial cyclotrons. Existing and potential markets for these cyclotrons will be presented. They will also discuss the possibility of systems capable of extracted energies up to 150 MeV and extracted beam currents of up to 2.0 mA.

  13. Cyclotron resonance effects on stochastic acceleration of light ionospheric ions

    NASA Technical Reports Server (NTRS)

    Singh, N.; Schunk, R. W.; Sojka, J. J.

    1982-01-01

    The production of energetic ions with conical pitch angle distributions along the auroral field lines is a subject of considerable current interest. There are several theoretical treatments showing the acceleration (heating) of the ions by ion cyclotron waves. The quasi-linear theory predicts no acceleration when the ions are nonresonant. In the present investigation, it is demonstrated that the cyclotron resonances are not crucial for the transverse acceleration of ions by ion cyclotron waves. It is found that transverse energization of ionospheric ions, such as He(+), He(++), O(++), and O(+), is possible by an Electrostatic Hydrogen Cyclotron (EHC) wave even in the absence of cyclotron resonance. The mechanism of acceleration is the nonresonant stochastic heating. However, when there are resonant ions both the total energy gain and the number of accelerated ions increase with increasing parallel wave number.

  14. Cyclotron resonance effects on stochastic acceleration of light ionospheric ions

    NASA Astrophysics Data System (ADS)

    Singh, N.; Schunk, R. W.; Sojka, J. J.

    1982-09-01

    The production of energetic ions with conical pitch angle distributions along the auroral field lines is a subject of considerable current interest. There are several theoretical treatments showing the acceleration (heating) of the ions by ion cyclotron waves. The quasi-linear theory predicts no acceleration when the ions are nonresonant. In the present investigation, it is demonstrated that the cyclotron resonances are not crucial for the transverse acceleration of ions by ion cyclotron waves. It is found that transverse energization of ionospheric ions, such as He(+), He(++), O(++), and O(+), is possible by an Electrostatic Hydrogen Cyclotron (EHC) wave even in the absence of cyclotron resonance. The mechanism of acceleration is the nonresonant stochastic heating. However, when there are resonant ions both the total energy gain and the number of accelerated ions increase with increasing parallel wave number.

  15. Acceleration of tritons with a compact cyclotron

    NASA Astrophysics Data System (ADS)

    Wegmann, H.; Huenges, E.; Muthig, H.; Morinaga, H.

    1981-01-01

    With the compact cyclotron at the Faculty of the Technical University of Munich, tritons have been accelerated to an energy of 7 MeV. A safe and reliable operation of the gas supply for the ion source was obtained by a new tritium storage system. A quantity of 1500 Ci tritium is stored by two special Zr-Al getter pumps in a non-gaseous phase. The tritium can be released in well-defined amounts by heating the getter material. During triton acceleration the pressure in the cyclotron vacuum chamber is maintained only by a large titanium sputter-ion pump, thus forming a closed vacuum system without any exhaust of tritium contaminated gas. Any tritium contaminations in the air can be detected by an extremely sensitive tritium monitoring system. The triton beam with a maximum intensity of 30 μA has been used so far to produce neutron-rich radioisotopes such as 28Mg, 43K or 72Zn, which are successfully applied in tracer techniques in the studies of biological systems.

  16. Ion cyclotron bands in VLF saucers

    NASA Technical Reports Server (NTRS)

    Maeda, Kaichi; Fung, Shing F.; Calvert, Wynne

    1990-01-01

    In the wideband VLF data obtained by the polar orbiting DE-1 satellite over the polar night ion trough region of the upper ionosphere, conspicuous frequency-band structures are found to occur both in absorption and emission, particularly associating with VLF saucers. The attenuation bands indicate that the ions of atomic hydrogen from the polar ionosphere are accelerated by the ac electric fields of VLF waves oscillating normal to the static magnetic field, analogous to a cyclotron accelerator. The observed frequencies of the cyclotron harmonics suggest that the acceleration is taking place in the layer below the satellite at a geocentric distance of less than about 1.5 earth radii. This example indicates the existence of upward propagating hiss at those altitudes inside the auroral zone. On the other hand, the frequency shifts of the emission bands are attributed to a combination of two different types of Doppler shift, one due to the orbital motion of the satellite and the other due to the upward motion of the medium at the emission source. This indicates the existence of an upward plasma flow at the source, with a velocity of the order of 20 km/s inside the saucer. The amount of this frequency shift decreases with increasing harmonic order, indicating a higher phase velocity for the electrostatic waves of higher harmonic order.

  17. Ion cyclotron emission studies: Retrospects and prospects

    NASA Astrophysics Data System (ADS)

    Gorelenkov, N. N.

    2016-05-01

    Ion cyclotron emission (ICE) studies emerged in part from the papers by A.B. Mikhailovskii published in the 1970s. Among the discussed subjects were electromagnetic compressional Alfvénic cyclotron instabilities with the linear growth rate √ {n_α /n_e } driven by fusion products, -particles which draw a lot of attention to energetic particle physics. The theory of ICE excited by energetic particles was significantly advanced at the end of the 20th century motivated by first DT experiments on TFTR and subsequent JET experimental studies which we highlight. More recently ICE theory was advanced by detailed theoretical and experimental studies on spherical torus (ST) fusion devices where the instability signals previously indistinguishable in high aspect ratio tokamaks due to high toroidal magnetic field became the subjects of experiments. We discuss further prospects of ICE theory applications for future burning plasma (BP) experiments such as those to be conducted in ITER device in France, where neutron and gamma rays escaping the plasma create extremely challenging conditions fusion alpha particle diagnostics.

  18. Loss cone-driven cyclotron maser instability

    NASA Astrophysics Data System (ADS)

    Lee, Sang-Yun; Yi, Sibaek; Lim, Dayeh; Kim, Hee-Eun; Seough, Jungjoon; Yoon, Peter H.

    2013-11-01

    The weakly (or mildly) relativistic cyclotron maser instability has been successfully applied to explain the Earth's auroral kilometric radiation and other radio sources in nature and laboratory. Among the most important physical parameters that determine the instability criteria is the ratio of plasma-to-electron cyclotron frequencies, ωp/Ω. It is therefore instructive to consider how the normalized maximum growth rate, γmax/Ω, varies as a function of ωp/Ω. Although many authors have already discussed this problem, in order to complete the analysis, one must also understand how the radiation emission angle corresponding to the maximum growth, θmax, scales with ωp/Ω, since the propagation angle determines the radiation beaming pattern. Also, the behavior of the frequency corresponding to the maximum growth rate at each harmonic, (ωmax-sΩ)/Ω, where s=1,2,3,ċ , as a function of ωp/Ωis of importance for a complete understanding of the maser excitation. The present paper computes these additional quantities for the first time, making use of a model loss cone electron distribution function.

  19. Cyclotron Resonances in Electron Cloud Dynamics

    SciTech Connect

    Celata, C. M.; Furman, Miguel A.; Vay, J.-L.; Ng, J. S.T.; Grote, D. P.; Pivi, M. T. F.; Wang, L. F.

    2009-04-29

    A new set of resonances for electron cloud dynamics in the presence of a magnetic field has been found. For short beam bunch lengths and low magnetic fields where lb<< 2pi c/omega c (with lb = bunch length, omega c = non-relativistic cyclotron frequency) resonances between the bunch frequency and harmonics of the electron cyclotron frequency cause an increase in the electron cloud density in narrow ranges of magnetic field near the resonances. For ILC parameters the increase in the density is up to a factor ~;;3, and the spatial distribution of the electrons is broader near resonances, lacking the well-defined vertical density"stripes" found for non-resonant cases. Simulations with the 2D computer code POSINST, as well as a single-particle tracking code, were used to elucidate the physics of the dynamics. The existence of the resonances has been confirmed in experiments at PEP-II. The resonances are expected to affect the electron cloud dynamics in the fringe fields of conventional lattice magnets and in wigglers, where the magnetic fields are low. Results of the simulations and experimental observations, the reason for the bunch-length dependence, and details of the dynamics are discussed here.

  20. Cyclotron Resonances in Electron Cloud Dynamics

    SciTech Connect

    Celata, C M; Furman, M A; Vay, J L; Grote, D P; Ng, J T; Pivi, M F; Wang, L F

    2009-05-05

    A new set of resonances for electron cloud dynamics in the presence of a magnetic field has been found. For short beam bunch lengths and low magnetic fields where l{sub b} << 2{pi}{omega}{sub c}, (l{sub b} = bunch duration, {omega}{sub c} = non-relativistic cyclotron frequency) resonances between the bunch frequency and harmonics of the cyclotron frequency cause an increase in the electron cloud density in narrow ranges of magnetic field near the resonances. For ILC parameters the increase in the density is up to a factor {approx} 3, and the spatial distribution of the electrons is broader near resonances, lacking the well-defined density 'stripes' of multipactoring found for non-resonant cases. Simulations with the 2D computer code POSINST, as well as a single-particle tracking code, were used to elucidate the physics of the dynamics. The resonances are expected to affect the electron cloud dynamics in the fringe fields of conventional lattice magnets and in wigglers, where the magnetic fields are low. Results of the simulations, the reason for the bunch-length dependence, and details of the dynamics will be discussed.

  1. Cyclotron and linac production of Ac-225.

    PubMed

    Melville, Graeme; Allen, Barry J

    2009-04-01

    Radium needles that were once implanted into tumours as a cancer treatment are now obsolete and constitute a radioactive waste problem, as their half-life is 1600 years. The reduction of radium by photonuclear transmutation by bombarding Ra-226 with high-energy photons from a medical linear accelerator (linac) has been investigated. A linac dose of 2800 Gy produced about 2.4 MBq (64 microCi) of Ra-225, which decays to Ac-225 and can then be used for 'Targeted Alpha Therapy' (TAT) of cancer. This result, while consistent with theoretical calculations, is far too low to be of practical use unless much larger quantities of radium are irradiated. The increasing application of Ac-225 for cancer therapy indicates the potential need for its increased production and availability. This paper investigates the possibility of producing of Ac-225 in commercial quantities, which could potentially reduce obsolete radioactive material and displace the need for expensive importation of Ac-225 from the USA and Russia in the years ahead. Scaled up production of Ac-225 could theoretically be achieved by the use of a high current cyclotron or linac. Production specifications are determined for a linac in terms of current, pulse length and frequency, as well as an examination of other factors such as radiation issues and radionuclei separation. Yields are compared with those calculated for the Australian National Cyclotron in Sydney. PMID:19135381

  2. Fundamental and harmonic electron cyclotron maser emission

    NASA Astrophysics Data System (ADS)

    Winglee, R. M.

    1985-10-01

    The plasma conditions and features of the energetic electron distribution in electron cyclotron maser emission for which growth in a particular mode is favored when the ratio of the plasma frequency omega(p) to the electron cyclotron frequency Omega(e) is greater than about 0.3 are determined. It is shown that growth at the fundamental is suppressed as omega(p)/Omega(e) increases and emission at harmonics of Omega(e) dominates. Growth at harmonics of Omega(e) is not restricted to the O and X modes, but can also occur for the Z mode. Whether or not growth in a particular mode dominates depends both on omega(p)/Omega(e) and on the form of the distribution. If the density of the energetic electrons is sufficiently large, the dispersion relations of the O and X modes are modified so that the group velocities of the growing O and X mode waves can be comparable to that of the growing Z mode waves.

  3. Electron Cyclotron Resonance Heating on TEXTOR

    SciTech Connect

    Westerhof, E.; Hoekzema, J.A.; Hogeweij, G.M.D.

    2005-02-15

    TEXTOR is equipped with two gyrotrons at 110 and 140 GHz, respectively. Both share a single power supply and a confocal quasi-optical transmission line. They cannot be operated simultaneously. The 110-GHz gyrotron with limited power and pulse length (300 kW; 200 ms) has been used in a first series of experiments on electron cyclotron resonance heating (ECRH) and electron cyclotron current drive (ECCD) and for collective Thomson scattering (CTS) diagnostics of energetic ions. In the future the 110-GHz gyrotron will be operated exclusively for CTS diagnostics, while for ECRH and ECCD, the newly installed 140-GHz, high-power (800-kW), long-pulse (>3-s) gyrotron is now available. The highlights of first ECRH experiments with the 110-GHz gyrotron are reported. These include observations of internal transport barriers with ECRH on various target plasmas: in the current plateau phase of both ohmic and radiation improved mode (RI-mode) discharges. In addition, sawtooth control by localized ECRH is demonstrated. First results on CTS include the observation of the slowing down of energetic ions and of the redistribution of energetic ions in sawtooth crashes.

  4. Coherent cyclotron motion beyond Kohn's theorem

    NASA Astrophysics Data System (ADS)

    Maag, T.; Bayer, A.; Baierl, S.; Hohenleutner, M.; Korn, T.; Schüller, C.; Schuh, D.; Bougeard, D.; Lange, C.; Huber, R.; Mootz, M.; Sipe, J. E.; Koch, S. W.; Kira, M.

    2016-02-01

    In solids, the high density of charged particles makes many-body interactions a pervasive principle governing optics and electronics. However, Walter Kohn found in 1961 that the cyclotron resonance of Landau-quantized electrons is independent of the seemingly inescapable Coulomb interaction between electrons. Although this surprising theorem has been exploited in sophisticated quantum phenomena, such as ultrastrong light-matter coupling, superradiance and coherent control, the complete absence of nonlinearities excludes many intriguing possibilities, such as quantum-logic protocols. Here, we use intense terahertz pulses to drive the cyclotron response of a two-dimensional electron gas beyond the protective limits of Kohn's theorem. Anharmonic Landau ladder climbing and distinct terahertz four- and six-wave mixing signatures occur, which our theory links to dynamic Coulomb effects between electrons and the positively charged ion background. This new context for Kohn's theorem unveils previously inaccessible internal degrees of freedom of Landau electrons, opening up new realms of ultrafast quantum control for electrons.

  5. Ion cyclotron emission studies: Retrospects and prospects

    DOE PAGESBeta

    Gorelenkov, N. N.

    2016-06-05

    Ion cyclotron emission (ICE) studies emerged in part from the papers by A.B. Mikhailovskii published in the 1970s. Among the discussed subjects were electromagnetic compressional Alfv,nic cyclotron instabilities with the linear growth rate similar ~ √(nα/ne) driven by fusion products, -particles which draw a lot of attention to energetic particle physics. The theory of ICE excited by energetic particles was significantly advanced at the end of the 20th century motivated by first DT experiments on TFTR and subsequent JET experimental studies which we highlight. Recently ICE theory was advanced by detailed theoretical and experimental studies on spherical torus (ST) fusionmore » devices where the instability signals previously indistinguishable in high aspect ratio tokamaks due to high toroidal magnetic field became the subjects of experiments. Finally, we discuss prospects of ICE theory applications for future burning plasma (BP) experiments such as those to be conducted in ITER device in France, where neutron and gamma rays escaping the plasma create extremely challenging conditions fusion alpha particle diagnostics.« less

  6. A community of scientists: cultivating scientific identity among undergraduates within the Berkeley Compass Project

    NASA Astrophysics Data System (ADS)

    Aceves, Ana V.; Berkeley Compass Project

    2015-01-01

    The Berkeley Compass Project is a self-formed group of graduate and undergraduate students in the physical sciences at UC Berkeley. Our goals are to improve undergraduate physics education, provide opportunities for professional development, and increase retention of students from populations typically underrepresented in the physical sciences. For students who enter as freshmen, the core Compass experience consists of a summer program and several seminar courses. These programs are designed to foster a diverse, collaborative student community in which students engage in authentic research practices and regular self-reflection. Compass encourages undergraduates to develop an identity as a scientist from the beginning of their university experience.

  7. Observations of Local ISM Emission with the Berkeley EUV/FUV Shuttle Telescope

    NASA Technical Reports Server (NTRS)

    Martin, C.; Bowyer, S.

    1984-01-01

    The Berkeley extreme ultraviolet/far ultraviolet shuttle telescope (BEST) will be launched on the Space Shuttle as part of the NASA UVX project. The Berkeley spectrometer will make observations of the cosmic diffuse background in the 600 to 1900 A band, with a spectral resolution of 10 A. The sensitivity and spectral resolution of the instrument make it ideal for the study of components of the interstellar medium in the 10 to the 4th power to 10 to the 6th power K range.

  8. Cyclotron Production of Technetium-99m

    NASA Astrophysics Data System (ADS)

    Gagnon, Katherine M.

    Technetium-99m (99mTc) has emerged as the most widely used radionuclide in medicine and is currently obtained from a 99Mo/ 99mTc generator system. At present, there are only a handful of ageing reactors worldwide capable of producing large quantities of the parent isotope, 99Mo, and owing to the ever growing shutdown periods for maintenance and repair of these ageing reactors, the reliable supply 99mTc has been compromised in recent years. With an interest in alternative strategies for producing this key medical isotope, this thesis focuses on several technical challenges related to the direct cyclotron production of 99mTc via the 100Mo(p,2n)99mTc reaction. In addition to evaluating the 100Mo(p,2n)99mTc and 100Mo(p,x)99Mo reactions, this work presented the first experimental evaluation of the 100Mo(p,2n) 99gTc excitation function in the range of 8-18 MeV. Thick target calculations suggested that large quantities of cyclotron-produced 99mTc may be possible. For example, a 6 hr irradiation at 500 μA with an energy window of 18→10 MeV is expected to yield 1.15 TBq of 99mTc. The level of coproduced 99gTc contaminant was found to be on par with the current 99Mo/99mTc generator standard eluted with a 24 hr frequency. Highly enriched 100Mo was required as the target material for 99mTc production and a process for recycling of this expensive material is presented. An 87% recovery yield is reported, including metallic target preparation, irradiation, 99mTc extraction, molybdate isolation, and finally hydrogen reduction to the metal. Further improvements are expected with additional optimization experiments. A method for forming structurally stable metallic molybdenum targets has also been developed. These targets are capable of withstanding more than a kilowatt of beam power and the reliable production and extraction of Curie quantities of 99mTc has been demonstrated. With the end-goal of using the cyclotron-produced 99mTc clinically, the quality of the cyclotron

  9. Electromagnetic ion cyclotron waves observed near the oxygen cyclotron frequency by ISEE 1 and 2

    NASA Technical Reports Server (NTRS)

    Fraser, B. J.; Samson, J. C.; Hu, Y. D.; Mcpherron, R. L.; Russell, C. T.

    1992-01-01

    The first results of observations of ion cyclotron waves by the elliptically orbiting ISEE 1 and 2 pair of spacecraft are reported. The most intense waves (8 nT) were observed in the outer plasmasphere where convection drift velocities were largest and the Alfven velocity was a minimum. Wave polarization is predominantly left-handed with propagation almost parallel to the ambient magnetic field, and the spectral slot and polarization reversal predicted by cold plasma propagation theory are identified in the wave data. Computations of the experimental wave spectra during the passage through the plasmapause show that the spectral slots relate to the local plasma parameters, possibly suggesting an ion cyclotron wave growth source near the spacecraft. A regular wave packet structure seen over the first 30 min of the event is attributed to the modulation of this energy source by the Pc 5 waves seen at the same time.

  10. Ground-based dosimetry support for experiment AR002

    NASA Technical Reports Server (NTRS)

    Cassou, R.; Benton, E. V.

    1976-01-01

    Actinomyces levoris colonies were exposed to alpha particles at the 184-inch cyclotron, and Streptomyces levoris colonies were exposed to Ne-20 ions. A description is given of the experimental conditions for each experiment along with tables listing the doses delivered to the colonies. The doses for the Actinomyces levoris exposures came from calibrations made by the cyclotron operators, while the doses for the Streptomyces levoris exposures came in part from cave calibrations and also in part from calculations.

  11. Excellence in Research: Creative Organizational Responses at Berkeley, Harvard, MIT, and Stanford. ASHE 1985 Annual Meeting Paper.

    ERIC Educational Resources Information Center

    Gardiner, John J.

    Research environments of four leading universities were studied: University of California at Berkeley (UC-Berkeley), Harvard University, Massachusetts Institute of Technology (MIT), and Stanford University. Attention was directed to organizational responses for encouraging collaboration in research at these leading universities, as well as to…

  12. A Profile of Minority Graduate Students at the University of California, Berkeley: Recruitment, Selection, Fields of Study and Financial Support.

    ERIC Educational Resources Information Center

    Collins, O. R.

    This paper presents a profile of minority graduate students at the University of California, Berkeley. Following a brief overview of Berkeley's Graduate Minority Program (GMP), data is presented concerning the number of GMP students supported; available funds and average grants for students from 1968-69 to 1973-74; distribution of GMP students…

  13. Follow the Money: Engineering at Stanford and UC Berkeley during the Rise of Silicon Valley

    ERIC Educational Resources Information Center

    Adams, Stephen B.

    2009-01-01

    A comparison of the engineering schools at UC Berkeley and Stanford during the 1940s and 1950s shows that having an excellent academic program is necessary but not sufficient to make a university entrepreneurial (an engine of economic development). Key factors that made Stanford more entrepreneurial than Cal during this period were superior…

  14. Summary of well-testing activities at Lawrence Berkeley Laboratory, 1975-1983

    SciTech Connect

    Bodvarsson, M.G.; Benson, S.M.

    1983-08-01

    Well test data collected from various geothermal fields by the geothermal group at Lawrence Berkeley Laboratory are presented. The type of well tests conducted, the instrumentation used and the data collected are described. Experience gained through interpretation of the data has helped identify problems in test procedures and interpretative methods.

  15. Visual Access to Visual Images: The UC Berkeley Image Database Project.

    ERIC Educational Resources Information Center

    Besser, Howard

    1990-01-01

    Discusses the problem of access in managing image collections and describes a prototype system for the University of California Berkeley which would include the University Art Museum, Architectural Slide Library, Geography Department's Map Library and Lowie Museum of Anthropology photographs. The system combines an online public access catalog…

  16. Integration of the Berkeley Elementary Schools: A Report to the Superintendent.

    ERIC Educational Resources Information Center

    Berkeley Unified School District, CA.

    The report, prepared for the superintendent of schools in Berkeley, presents the proposals for and methods of achieving total quality integrated education throughout the school system. The document traces the development of the thrust toward school desegregation in the city. Various proposals and plans are suggested and the recommendations of the…

  17. Ernest Orlando Lawrence Berkeley National Laboratory Institutional Plan FY 2000-2004

    SciTech Connect

    Chartock, Mike; Hansen, Todd

    1999-08-01

    The FY 2000-2004 Institutional Plan provides an overview of the Ernest Orlando Lawrence Berkeley National Laboratory (Berkeley Lab, the Laboratory) mission, strategic plan, initiatives, and the resources required to fulfill its role in support of national needs in fundamental science and technology, energy resources, and environmental quality. To advance the Department of Energy's ongoing efforts to define the Integrated Laboratory System, the Berkeley Lab Institutional Plan reflects the strategic elements of our planning efforts. The Institutional Plan is a management report that supports the Department of Energy's mission and programs and is an element of the Department of Energy's strategic management planning activities, developed through an annual planning process. The Plan supports the Government Performance and Results Act of 1993 and complements the performance-based contract between the Department of Energy and the Regents of the University of California. It identifies technical and administrative directions in the context of the national energy policy and research needs and the Department of Energy's program planning initiatives. Preparation of the plan is coordinated by the Office of Planning and Communications from information contributed by Berkeley Lab's scientific and support divisions.

  18. Intern Teachers and Student Teacher at the University of California, Berkeley: A Comparative Study.

    ERIC Educational Resources Information Center

    Stone, James C.

    This study compared students in Berkeley's four postgraduate teacher education programs, which are a) student teaching--elementary; b) elementary internship; c) student teaching--secondary; and d) secondary internship. The impact of each curriculum on the students was investigated through the Terman Concept Mastery Test, Omnibus Personality…

  19. The Berkeley Puppet Interview: A Screening Instrument for Measuring Psychopathology in Young Children

    ERIC Educational Resources Information Center

    Stone, Lisanne L.; van Daal, Carlijn; van der Maten, Marloes; Engels, Rutger C. M. E.; Janssens, Jan M. A. M.; Otten, Roy

    2014-01-01

    Background: While child self-reports of psychopathology are increasingly accepted, little standardized instruments are utilized for these practices. The Berkeley Puppet Interview (BPI) is an age-appropriate instrument for self-reports of problem behavior by young children. Objective: Psychometric properties of the Dutch version of the BPI will be…

  20. You Learn What You Eat: Cognition Meets Nutrition in Berkeley Schools.

    ERIC Educational Resources Information Center

    Sobel, David

    2001-01-01

    In the past 5 years, the Center for Ecoliteracy's Food Systems Project has grown from one schoolyard garden to the complete reinvention of Child Nutrition Services throughout the Berkeley Unified School District. Using food as the organizing principle for systemic change, the project is devising a pattern of healthy food, improved academic…

  1. UC Berkeley's Undocumented Student Program: Holistic Strategies for Undocumented Student Equitable Success across Higher Education

    ERIC Educational Resources Information Center

    Sanchez, Ruben Elias Canedo; So, Meng L.

    2015-01-01

    In this essay, Ruben Elias Canedo Sanchez and Meng L. So share the history and development of the Undocumented Student Program at the University of California, Berkeley. In describing the creation of the program, the authors offer reflections on the strategies employed to holistically support undocumented students' success on campus. By drawing on…

  2. Berkeley Foundation for Opportunities in Information Technology: A Decade of Broadening Participation

    ERIC Educational Resources Information Center

    Crutchfield, Orpheus S. L.; Harrison, Christopher D.; Haas, Guy; Garcia, Daniel D.; Humphreys, Sheila M.; Lewis, Colleen M.; Khooshabeh, Peter

    2011-01-01

    The Berkeley Foundation for Opportunities in Information Technology is a decade-old endeavor to expose pre-college young women and underrepresented racial and ethnic minorities to the fields of computer science and engineering, and prepare them for rigorous, university-level study. We have served more than 150 students, and graduated more than 65…

  3. "A Woman's World": The University of California, Berkeley, during the Second World War

    ERIC Educational Resources Information Center

    Dorn, Charles

    2008-01-01

    During World War II, female students at the University of California, Berkeley--then the most populous undergraduate campus in American higher education--made significant advances in collegiate life. In growing numbers, women enrolled in male-dominated academic programs, including mathematics, chemistry, and engineering, as they prepared for…

  4. The University of California at Berkeley: An Emerging Global Research University

    ERIC Educational Resources Information Center

    Ma, Wanhua

    2008-01-01

    Federal government science policy and R&D investment are two major factors for the success of research universities in the United States. This case analysis examines how the University of California at Berkeley shifted from a regional to a globally oriented research university by the influence of federal government science policy and R&D…

  5. Searching the "Nuclear Science Abstracts" Data Base by Use of the Berkeley Mass Storage System

    ERIC Educational Resources Information Center

    Herr, J. Joanne; Smith, Gloria L.

    1972-01-01

    Advantages of the Berkeley Mass Storage System (MSS) for information retrieval other than its size are: high serial-read rate, archival data storage; and random-access capability. By use of this device, the search cost in an SDI system based on the Nuclear Science Abstracts" data base was reduced by 20 percent. (6 references) (Author/NH)

  6. An Evaluation of the New Curriculum at the University of California, Berkeley, School of Optometry.

    ERIC Educational Resources Information Center

    Harris, Michael G.; Kashani, Sandy; Saroj, Namrata

    2001-01-01

    Evaluated the new curriculum at the University of California, Berkeley, School of Optometry by comparing the content of the new curriculum to the old curriculum and by surveying faculty and students regarding their opinion of the new curriculum. Findings indicated that the curriculum is successful in implementing desired changes, including reduced…

  7. The Berkeley Environmental Simulation Laboratory: Its Use In Environmental Impact Assessment.

    ERIC Educational Resources Information Center

    Appleyard, Donald; And Others

    An environmental simulation laboratory at the University of California, Berkeley, is testing the adequacy of different techniques for simulating environmental experiences. Various levels of realism, with various costs, are available in different presentation modes. The simulations can aid in communication about and the resolution of environmental…

  8. Examination of Grants Awarded to the Berkeley Unified School District and to Bilingual Children's Television, Inc.

    ERIC Educational Resources Information Center

    Comptroller General of the U.S., Washington, DC.

    At the request of Congresswoman Edith Green, the Comptroller General of the United States reviewed grant procedures covering two awards made by the Office of Education (OE). The first award, made to the Berkeley Unified School District, was funded under Title VII of the Elementary and Secondary Education Act of 1965, as amended, which provides…

  9. Energy Efficient Buildings and Appliances: From Berkeley Lab to the Marketplace (LBNL Summer Lecture Series)

    ScienceCinema

    Rosenfeld, Art [Commissioner, California Energy Commission

    2011-04-28

    Summer Lecture Series 2006: Art Rosenfeld, an appointee to the California Energy Commission and one of the architects of energy efficiency research at Berkeley Lab in the 1970s, discusses what it takes to shepherd innovative energy efficiency research from the lab to the real world.

  10. High Schools Today: Overview and Implications for the University of California, Berkeley.

    ERIC Educational Resources Information Center

    Scherini, Rose

    The academic characteristics of freshmen entering the University of California, Berkeley (UCB), major problems in secondary education, and ways that the university can affect the quality of secondary education are examined. Data on entering freshmen for 1970-1980 indicate that UCB freshmen have consistently scored higher on admissions tests than…

  11. Electron cyclotron resonance ion source DECRIS-4 for the U400 cyclotron

    SciTech Connect

    Leporis, M.; Bekhterev, V.; Bogomolov, S.; Efremov, A.; Gulbekian, G.; Kostyukhov, Yu.; Lebedev, A.; Loginov, V.; Yazvitsky, N.

    2006-03-15

    The electron cyclotron resonance ion source DECRIS-4 has been designed and constructed at the FLNR to be used as a second injector of heavy multiply charged ions for the U-400 cyclotron. After the modification of the injection side this source can be also used as a 'charge breeder' (the ''1{sup +}{yields}n{sup +}'' method) for the second phase of the Dubna radioactive ion beams project. The main feature of the ion source design is the creation of the extended resonance zone in a comparatively compact electron cyclotron resonance ion source. For this purpose the axial magnetic field is formed with a flat minimum. In this case the superposition of the axial magnetic field and the radial field of the permanent-magnet hexapole, made from NdFeB, allows one to create a larger resonance volume. For the plasma heating a microwave frequency of 14 GHz is used. In this paper we will present the basic design features of the ion source, including the results of the magnetic-field measurements. Some preliminary results of ion source tests are also reported.

  12. Multiple Landslide-Hazard Scenarios Modeled for the Oakland-Berkeley Area, Northern California

    USGS Publications Warehouse

    Pike, Richard J.; Graymer, Russell W.

    2008-01-01

    With the exception of Los Angeles, perhaps no urban area in the United States is more at risk from landsliding, triggered by either precipitation or earthquake, than the San Francisco Bay region of northern California. By January each year, seasonal winter storms usually bring moisture levels of San Francisco Bay region hillsides to the point of saturation, after which additional heavy rainfall may induce landslides of various types and levels of severity. In addition, movement at any time along one of several active faults in the area may generate an earthquake large enough to trigger landslides. The danger to life and property rises each year as local populations continue to expand and more hillsides are graded for development of residential housing and its supporting infrastructure. The chapters in the text consist of: *Introduction by Russell W. Graymer *Chapter 1 Rainfall Thresholds for Landslide Activity, San Francisco Bay Region, Northern California by Raymond C. Wilson *Chapter 2 Susceptibility to Deep-Seated Landsliding Modeled for the Oakland-Berkeley Area, Northern California by Richard J. Pike and Steven Sobieszczyk *Chapter 3 Susceptibility to Shallow Landsliding Modeled for the Oakland-Berkeley Area, Northern California by Kevin M. Schmidt and Steven Sobieszczyk *Chapter 4 Landslide Hazard Modeled for the Cities of Oakland, Piedmont, and Berkeley, Northern California, from a M=7.1 Scenario Earthquake on the Hayward Fault Zone by Scott B. Miles and David K. Keefer *Chapter 5 Synthesis of Landslide-Hazard Scenarios Modeled for the Oakland-Berkeley Area, Northern California by Richard J. Pike The plates consist of: *Plate 1 Susceptibility to Deep-Seated Landsliding Modeled for the Oakland-Berkeley Area, Northern California by Richard J. Pike, Russell W. Graymer, Sebastian Roberts, Naomi B. Kalman, and Steven Sobieszczyk *Plate 2 Susceptibility to Shallow Landsliding Modeled for the Oakland-Berkeley Area, Northern California by Kevin M. Schmidt and Steven

  13. Ion Cyclotron Waves in the Solar Wind

    NASA Astrophysics Data System (ADS)

    Wei, H. Y.; Jian, L. K.; Russell, C. T.; Omidi, N.

    2016-02-01

    The ion cyclotron waves (ICWs) refer to electromagnetic transverse waves with nearly field-aligned propagation, circular polarization, and frequencies near the proton gyro-frequency. This chapter presents the ICW studies observed in the solar wind over a wide range of heliocentric distances, at all solar longitudes, and at locations far from planets or comets. To better understand the wave source region, case studies have been performed on a special group of ICW storm events, in which the left-handed (LH) and right-handed (RH) waves were observed simultaneously in the spacecraft frame. The study in the chapter assumes the waves are generated through one possible mechanism (i.e., the temperature anisotropy instability). The variations of the wave properties with heliocentric distances may also provide information on the possible wave generation sources and the effects of the wave to the solar wind plasma.

  14. Folded waveguide coupler for ion cyclotron heating

    SciTech Connect

    Owens, T.L.; Chen, G.L.

    1986-01-01

    A new type of waveguide coupler for plasma heating in the ion cyclotron range of frequencies is described. The coupler consists of a series of interleaved metallic vanes within a rectangular enclosure analogous to a wide rectangular waveguide that has been ''folded'' several times. At the mouth of the coupler, a plate is attached which contains coupling apertures in each fold or every other fold of the waveguide, depending upon the wavenumber spectrum desired. This plate serves primarily as a wave field polarizer that converts coupler fields to the polarization of the fast magnetosonic wave within the plasma. Theoretical estimates indicate that the folded waveguide is capable of high-efficiency, multimegawatt operation into a plasma. Bench tests have verified the predicted field structure within the waveguide in preparation for high-power tests on the Radio Frequency Test Facility at the Oak Ridge National Laboratory.

  15. Cyclotron side band emissions from magnetospheric electrons

    NASA Technical Reports Server (NTRS)

    Maeda, K.

    1975-01-01

    Very low frequency emissions with subharmonic cyclotron frequency from magnetospheric electrons were detected by the S(3)-A satellite (Explorer 45) whose orbit is close to the magnetic equatorial plane where the wave-particle interaction is most efficient. These emissions were observed during the main phase of a geomagnetic storm in the nightside of the magnetosphere outside of the plasmasphere. During the event of these side-band emissions, the pitch angle distributions of high energy electrons (greater than 50 keV) and of energetic protons (greater than 100 keV) showed remarkable changes with time, whereas those of low energy electrons and protons remained approximately isotropic. In this type of event, emissions consist essentially of two bands, the one below the equatorial electron gyrofrequency, and the other above. The emissions below are whistler mode, and the emissions above are electrostatic mode.

  16. Single-pass ion cyclotron resonance absorption

    SciTech Connect

    Breizman, Boris N.; Arefiev, Alexey V.

    2001-03-01

    The ion response to the rf-field during single-pass ion-cyclotron resonance heating (ICRH) can be essentially nonlinear. This paper presents a self-consistent theory of the rf-wave propagation and ion motion through the resonance. An important ingredient of the problem is the ion flow along the magnetic field. The flow velocity limits the time the ions spend at the resonance, which in turn limits the ion energy gain. A feature that makes the problem nonlinear is that the flow accelerates under the effect of the {nabla}B force and rf-pressure. This acceleration can produce a steep decrease in the plasma density at the resonance, resulting in partial reflection of the incident wave.

  17. Electron Cyclotron Resonances in Electron Cloud Dynamics

    SciTech Connect

    Celata, Christine; Celata, C.M.; Furman, Miguel A.; Vay, J.-L.; Yu, Jennifer W.

    2008-06-25

    We report a previously unknown resonance for electron cloud dynamics. The 2D simulation code"POSINST" was used to study the electron cloud buildup at different z positions in the International Linear Collider positron damping ring wiggler. An electron equilibrium density enhancement of up to a factor of 3 was found at magnetic field values for which the bunch frequency is an integral multiple of the electron cyclotron frequency. At low magnetic fields the effects of the resonance are prominent, but when B exceeds ~;;(2 pi mec/(elb)), with lb = bunch length, effects of the resonance disappear. Thus short bunches and low B fields are required for observing the effect. The reason for the B field dependence, an explanation of the dynamics, and the results of the 2D simulations and of a single-particle tracking code used to elucidate details of the dynamics are discussed.

  18. Improving cancer treatment with cyclotron produced radionuclides. Progress report

    SciTech Connect

    Larson, S.M.; Finn, R.D.

    1993-11-01

    This report describes our continuing long term goal of promoting nuclear medicine applications by improving the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The program includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. An essential strategy is as follows: novel radionuclides and radiotracers developed in the Radiochemistry/Cyclotron section will be employed in the Pharmacology and Immunology sections during the next year. The development of novel radionuclides and tracers is of course useful in and of itself, but their utility is greatly enhanced by the interaction with the immunology and pharmacology components of the program.

  19. Evidence for cyclotron maser emission from the sun and stars

    NASA Technical Reports Server (NTRS)

    Dulk, G. A.; Winglee, R. M.

    1987-01-01

    Recent observational and theoretical work on cyclotron maser instability is reviewed, with emphasis on the similarities between microwave spike bursts from the sun and bursts from stars and planets. Results on particle-in-cell simulations are discussed, and it is suggested that such studies may provide further information on the amount and efficiency of energy transfer by the maser radiation. Observational tests of the cyclotron maser theory are considered, in addition to the role of the cyclotron maser as an energy transport mechanism in solar flares.

  20. Ionospheric modification at twice the electron cyclotron frequency.

    PubMed

    Djuth, F T; Pedersen, T R; Gerken, E A; Bernhardt, P A; Selcher, C A; Bristow, W A; Kosch, M J

    2005-04-01

    In 2004, a new transmission band was added to the HAARP high-frequency ionospheric modification facility that encompasses the second electron cyclotron harmonic at altitudes between approximately 220 and 330 km. Initial observations indicate that greatly enhanced airglow occurs whenever the transmission frequency approximately matches the second electron cyclotron harmonic at the height of the upper hybrid resonance. This is the reverse of what happens at higher electron cyclotron harmonics. The measured optical emissions confirm the presence of accelerated electrons in the plasma. PMID:15903924

  1. Global Simulation of Electromagnetic Ion Cyclotron Waves

    NASA Technical Reports Server (NTRS)

    Khazanov, G. V.; Gamayunov, K.; Gallagher, D. L.; Kozyra, J. U.

    2007-01-01

    It is well known that the effects of electromagnetic ion cyclotron (EMIC) waves on ring current (RC) ion and radiation belt (RB) electron dynamics strongly depend on such particle/wave characteristics as the phase-space distribution function, frequency, wave-normal angle, wave energy, and the form of wave spectral energy density. The consequence is that accurate modeling of EMIC waves and RC particles requires robust inclusion of the interdependent dynamics of wave growth/damping, wave propagation, and particles. Such a self-consistent model is being progressively developed by Khazanov et al. [2002 - 2007]. This model is based on a system of coupled kinetic equations for the RC and EMIC wave power spectral density along with the ray tracing equations. We will discuss the recent progress in understanding EMIC waves formation mechanisms in the inner magnetosphere. This problem remains unsettled in spite of many years of experimental and theoretical studies. Modern satellite observations by CRRES, Polar and Cluster still do not reveal the whole picture experimentally since they do not stay long enough in the generation region to give a full account of all the spatio-temporal structure of EMIC waves. The complete self-consistent theory taking into account all factors significant for EMIC waves generation remains to be developed. Several mechanisms are discussed with respect to formation of EMIC waves, among them are nonlinear modification of the ionospheric reflection by precipitating energetic protons, modulation of ion-cyclotron instability by long-period (Pc3/4) pulsations, reflection of waves from layers of heavy-ion gyroresonances, and nonlinearities of wave generation process. We show that each of these mechanisms have their attractive features and explains certain part experimental data but any of them, if taken alone, meets some difficulties when compared to observations. We conclude that development of a refined nonlinear theory and further correlated analysis

  2. Global Simulation of Electromagnetic Ion Cyclotron Waves

    NASA Technical Reports Server (NTRS)

    Khazanov, George V.; Gallagher, D. L.; Kozyra, J. U.

    2007-01-01

    It is very well known that the effects of electromagnetic ion cyclotron (EMIC) waves on ring current (RC) ion and radiation belt (RB) electron dynamics strongly depend on such particle/wave characteristics as the phase-space distribution function, frequency, wave-normal angle, wave energy, and the form of wave spectral energy density. The consequence is that accurate modeling of EMIC waves and RC particles requires robust inclusion of the interdependent dynamics of wave growth/damping, wave propagation, and particles. Such a self-consistent model is being progressively developed by Khazanov et al. This model is based on a system of coupled kinetic equations for the RC and EMIC wave power spectral density along with the ray tracing equations. We will discuss the recent progress in understanding EMIC waves formation mechanisms in the inner magnetosphere. This problem remains unsettled in spite of many years of experimental and theoretical studies. Modern satellite observations by CRRES, Polar and Cluster still do not reveal the whole picture experimentally since they do not stay long enough in the generation region to give a full account of all the spatio-temporal structure of EMIC waves. The complete self-consistent theory taking into account all factors significant for EMIC waves generation remains to be developed. Several mechanisms are discussed with respect to formation of EMIC waves, among them are nonlinear modification of the ionospheric reflection by precipitating energetic protons, modulation of ion-cyclotron instability by long-period (Pc3/4) pulsations, reflection of waves from layers of heavy-ion gyroresonances, and nonlinearities of wave generation process. We show that each of these mechanisms have their attractive features and explains certain part experimental data but any of them, if taken alone, meets some difficulties when compared to observations. We conclude that development of a refined nonlinear theory and further correlated analysis of modern

  3. The NSCL cyclotron gas stopper - Entering commissioning

    NASA Astrophysics Data System (ADS)

    Schwarz, S.; Bollen, G.; Chouhan, S.; Das, J. J.; Green, M.; Magsig, C.; Morrissey, D. J.; Ottarson, J.; Sumithrarachchi, C.; Villari, A. C. C.; Zeller, A.

    2016-06-01

    Linear gas stopping cells have been used successfully at NSCL to slow down ions produced by projectile fragmentation from the 100 MeV/u to the keV energy range. These 'stopped beams' have first been used for low-energy high precision experiments and more recently for NSCLs re-accelerator ReA. A gas-filled reverse cyclotron is currently under construction by the NSCL to complement the existing stopping cells: Due to its extended stopping length, efficient stopping and fast extraction is expected even for light and medium-mass ions, which are difficult to thermalize in linear gas cells. The device is based on a 2.6 T maximum-field cyclotron-type magnet to confine the injected beam while it is slowed down in ≈100 mbar of LN2-temperature helium gas. Once thermalized, the beam will be transported to the center of the device by a traveling-wave RF-carpet system, extracted along the symmetry axis with an ion conveyor and miniature RF-carpets, and accelerated to a few tens of keV of energy for delivery to the users. The superconducting magnet has been constructed on a 60 kV platform and energized to its nominal field strength. The magnet's two cryostats use 3 cryo-refrigerators each and liquid-nitrogen cooled thermal shields to cool the coil pair to superconductivity. This concept, chosen not to have to rely on external liquid helium, has been working well. Measurements of axial and radial field profiles confirm the field calculations. The individual RF-ion guiding components for low-energy ion transport through the device have been tested successfully. The beam stopping chamber with its 0.9 m-diameter RF carpet system and the ion extraction system are being prepared for installation inside the magnet for low-energy ion transport tests.

  4. The NSCL cyclotron gas stopper - Under construction

    NASA Astrophysics Data System (ADS)

    Schwarz, S.; Bollen, G.; Brodeur, M.; Chouhan, S. S.; DeKamp, J.; Gehring, A. E.; Joshi, N. S.; Magsig, C.; Morrissey, D. J.; Ringle, R.; Ottarson, J.; Zeller, A. F.

    2013-12-01

    Rare isotopes are produced at the NSCL by projectile fragmentation at energies on the order of 100 MeV/u for a wide range of research. In order to provide these exotic ions to low-energy high precision experiments such as the Penning-trap mass spectrometer LEBIT and the collinear laser spectroscopy setup, or to the NSCL's re-accelerator (ReA), the beam must be slowed down into the eV range by solid degraders and interaction with buffer gas. A novel gas-filled reverse cyclotron is currently under construction by the NSCL and will complement a recently installed linear gas-filled cell. The new device is based on a 2.6 T maximum-field cyclotron-type three-sectored magnet to confine the injected beam while it is slowed down in ≈100 mbar of high-purity helium gas, cooled to liquid-nitrogen temperature. Once thermalized, the beam is transported to the center of the device by a novel RF-carpet system, extracted along the symmetry axis and accelerated to a few tens of keV of energy for delivery to the users. The device has been characterized in numerous simulations with full 3D models of its magnetic field. The beam transport has been modeled from the fragment separator to the point where they reach thermal energies. The simulations indicate that very efficient stopping and fast extraction will be possible even for light and medium-mass ions, which are difficult to efficiently thermalize in linear gas cells. Construction of the device is well underway and initial tests are planned for later this year. The design and the predicted performance of the machine is discussed and its construction status is given.

  5. Cyclist safety on bicycle boulevards and parallel arterial routes in Berkeley, California.

    PubMed

    Minikel, Eric

    2012-03-01

    This study compares the safety of bicyclists riding on bicycle boulevards to those riding on parallel arterial routes in Berkeley, California. Literature on the impact of motor vehicle traffic characteristics on cyclist safety shows that high motor vehicle speeds and volumes and the presence of heavy vehicles are all detrimental to cyclist safety. This suggests that cyclists may be safer on side streets than on busy arterials. Bicycle boulevards-traffic-calmed side streets signed and improved for cyclist use-purport to offer cyclists a safer alternative to riding on arterials. Police-reported bicycle collision data and manually collected cyclist count data from bicycle boulevards and parallel arterial routes in Berkeley, California from 2003 to 2010 are used to test the hypothesis that Berkeley's bicycle boulevards have lower cyclist collision rates and a lower proportion of bicycle collisions resulting in severe injury. While no significant difference is found in the proportion of collisions that are severe, results show that collision rates on Berkeley's bicycle boulevards are two to eight times lower than those on parallel, adjacent arterial routes. The difference in collision rate is highly statistically significant, unlikely to be caused by any bias in the collision and count data, and cannot be easily explained away by self-selection or safety in numbers. Though the used dataset is limited and the study design is correlational, this study provides some evidence that Berkeley's bicycle boulevards are safer for cyclists than its parallel arterial routes. The results may be suggestive that, more generally, properly implemented bicycle boulevards can provide cyclists with a safer alternative to riding on arterials. PMID:22269506

  6. A Comparison of Particulate Matter Concentrations in West Oakland and Berkeley, California

    NASA Astrophysics Data System (ADS)

    Artis, M.; Bailey, D.; Delfin-Polk, S.; Figueroa, L.; Harris, S.; Haynes, C.; Johnson, K.; Lewis, K.; Marks-Block, T.; Martin, C.; Vieira, A.; Williams, J.

    2011-12-01

    Using a Dustrak 8530 aerosol sensor equipped with a Global Positioning System (GPS) receiver, and a Fluke 983 particle counter our research team collected Particulate Matter (PM) data throughout the communities of West Oakland and Berkeley, California. Data was collected by walking on foot along paths that wound through residential areas as well as busy intersections in each community. Identical starting times and locations were implemented in association with each in West Oakland. To reach Berkeley, research team members traveled from West Oakland on a local commuter train (Bay Area Rapid Transit), on which data also was collected. Using the Dustrak instrument samples of particulate (<2.5μm) mass (μg) in a given volume (m3) were collected every second, and using the Fluke instrument samples of particle sizes ranging from 0.3μm to 10μm were collected at specified locations and analyzed for concentration levels . Preliminary results indicate higher average PM concentrations in West Oakland compared to Berkeley sampling locations, as well as high PM concentration levels at points along the commuter train route, including those associated with underground locations. These results support our initial hypothesis that West Oakland has higher levels of PM compared to Berkeley, most likely due to its proximity to a major, functioning port and because it has considerably less street and backyard vegetation to filter PM. However, PM concentration levels in certain areas of Berkeley with heavy traffic did mirror PM averages in West Oakland, and above average PM levels were found in areas with ongoing construction in both communities.

  7. A line-of-sight electron cyclotron emission receiver for electron cyclotron resonance heating feedback control of tearing modes.

    PubMed

    Oosterbeek, J W; Bürger, A; Westerhof, E; de Baar, M R; van den Berg, M A; Bongers, W A; Graswinckel, M F; Hennen, B A; Kruijt, O G; Thoen, J; Heidinger, R; Korsholm, S B; Leipold, F; Nielsen, S K

    2008-09-01

    An electron cyclotron emission (ECE) receiver inside the electron cyclotron resonance heating (ECRH) transmission line has been brought into operation. The ECE is extracted by placing a quartz plate acting as a Fabry-Perot interferometer under an angle inside the electron cyclotron wave (ECW) beam. ECE measurements are obtained during high power ECRH operation. This demonstrates the successful operation of the diagnostic and, in particular, a sufficient suppression of the gyrotron component preventing it from interfering with ECE measurements. When integrated into a feedback system for the control of plasma instabilities this line-of-sight ECE diagnostic removes the need to localize the instabilities in absolute coordinates. PMID:19044409

  8. Transverse-longitudinal coupling by space charge in cyclotrons

    NASA Astrophysics Data System (ADS)

    Baumgarten, C.

    2011-11-01

    A method is presented that enables one to compute the parameters of matched beams with space charge in cyclotrons with emphasis on the effect of the transverse-longitudinal coupling. Equations describing the transverse-longitudinal coupling and corresponding tune shifts in first order are derived for the model of an azimuthally symmetric cyclotron. The eigenellipsoid of the beam is calculated and the transfer matrix is transformed into block-diagonal form. The influence of the slope of the phase curve on the transverse-longitudinal coupling is accounted for. The results are generalized and numerical procedures for the case of an azimuthally varying field cyclotron are presented. The algorithm is applied to the PSI injector II and ring cyclotron and the results are compared to TRANSPORT.

  9. Undergraduate Education with the Rutgers 12-Inch Cyclotron

    NASA Astrophysics Data System (ADS)

    Koeth, Timothy W.

    The Rutgers 12-Inch Cyclotron is a research grade accelerator dedicated to undergraduate education. From its inception, it has been intended for instruction and has been designed to demonstrate classic beam physics phenomena and provides students hands on experience with accelerator technology. The cyclotron is easily reconfigured, allowing experiments to be designed and performed within one academic semester. Our cyclotron offers students the opportunity to operate an accelerator and directly observe many fundamental beam physics concepts, including axial and radial betatron motion, destructive resonances, weak and azimuthally varying field (AVF) focusing schemes, RF and DEE voltage effects, diagnostic techniques, and perform low energy nuclear reactions. This paper emphasizes the unique beam physics measurements and beam manipulations capable at the Rutgers 12-Inch Cyclotron.

  10. Cyclotrons for clinical and biomedical research with PET

    SciTech Connect

    Wolf, A.P.

    1987-01-01

    The purpose of this commentary is to present some background material on cyclotrons and other particle accelerators particularly with a view toward the considerations behind acquiring and installing such a machine for purely clinical and/or biomedical research use.

  11. 6D Muon Ionization Cooling with an Inverse Cyclotron

    SciTech Connect

    Summers, D. J.; Bracker, S. B.; Cremaldi, L. M.; Godang, R.; Palmer, R. B.

    2006-03-20

    A large admittance sector cyclotron filled with LiH wedges surrounded by helium or hydrogen gas is explored. Muons are cooled as they spiral adiabatically into a central swarm. As momentum approaches zero, the momentum spread also approaches zero. Long bunch trains coalesce. Energy loss is used to inject the muons into the outer rim of the cyclotron. The density of material in the cyclotron decreases adiabatically with radius. The sector cyclotron magnetic fields are transformed into an azimuthally symmetric magnetic bottle in the center. Helium gas is used to inhibit muonium formation by positive muons. Deuterium gas is used to allow captured negative muons to escape via the muon catalyzed fusion process. The presence of ionized gas in the center may automatically neutralize space charge. When a bunch train has coalesced into a central swarm, it is ejected axially with an electric kicker pulse.

  12. Heavy-ion injection from tandems into an isochronous cyclotron

    SciTech Connect

    LeVine, M.J.; Chasman, C.

    1981-01-01

    A design has been realized for the injection of heavy ion beams generated by the BNL 3-stage tandem facility into a proposed isochronous cyclotron. The tandem beams are bunched into +- 1/sup 0/ R.F. phase (less than or equal to 0.5 nsec) in two stages. The beam is then injected into the cyclotron through a valley, past a hill, and into the next valley on to a stripper foil. Only a single steerer is required to make trajectory corrections for the different beams. Two achromats are used to regulate the tandem potential and to provide phase control. A final section of the injection optics provides matching of transverse phase space to the acceptance of the cyclotron. The calculations use realistic tandem emittances and magnetic fields for the cyclotron based on measurements with a model magnet.

  13. Flat-top system of the DC-280 cyclotron

    NASA Astrophysics Data System (ADS)

    Gulbekyan, G. G.; Buzmakov, V. A.; Zarubin, V. B.; Ivanenko, I. A.; Kazarinov, N. Yu.; Karamysheva, G. A.; Franko, I.

    2013-07-01

    The flat-top cavity of the radio-frequency accelerating system designed at the Flerov Laboratory of Nuclear Reactions, Joint Institute for Nuclear Research, for the DC-280 cyclotron is described. The cyclotron is intended for increasing the capabilities and efficiency of experiments on the synthesis of super-heavy elements and an investigation of their nuclear physical and chemical properties. The DC-280 isochronous heavy-ion cyclotron will produce accelerated beam of ions in the range from neon to uranium. The parameters, design, and results of the experimental and 3D computer modeling of the flat-top cavity of the RF accelerating system of the DC-280 cyclotron are reported.

  14. Some calculations of the resonator in INR cyclotron

    SciTech Connect

    Zhang, J.; Liu, X.L.

    1985-10-01

    Some calculation methods of the resonator parameters with single dee and two coaxial transmission lines in INR variable-energy cyclotron were described. Also calculated and experimental results have been compared with the original one (two dee system).

  15. Single-electron detection and spectroscopy via relativistic cyclotron radiation

    SciTech Connect

    Asner, David M.; Bradley, Rich; De Viveiros Souza Filho, Luiz A.; Doe, Peter J.; Fernandes, Justin L.; Fertl, M.; Finn, Erin C.; Formaggio, Joseph; Furse, Daniel L.; Jones, Anthony M.; Kofron, Jared N.; LaRoque, Benjamin; Leber, Michelle; MCBride, Lisa; Miller, M. L.; Mohanmurthy, Prajwal T.; Monreal, Ben; Oblath, Noah S.; Robertson, R. G. H.; Rosenberg, Leslie; Rybka, Gray; Rysewyk, Devyn M.; Sternberg, Michael G.; Tedeschi, Jonathan R.; Thummler, Thomas; VanDevender, Brent A.; Woods, N. L.

    2015-04-01

    It has been understood since 1897 that accelerating charges should emit electromagnetic radiation. Cyclotron radiation, the particular form of radiation emitted by an electron orbiting in a magnetic field, was first derived in 1904. Despite the simplicity of this concept, and the enormous utility of electron spectroscopy in nuclear and particle physics, single-electron cyclotron radiation has never been observed directly. Here we demonstrate single-electron detection in a novel radiofrequency spectrometer. We observe the cyclotron radiation emitted by individual electrons that are produced with mildly-relativistic energies by a gaseous radioactive source and are magnetically trapped. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay endpoint, and this work is a proof-of-concept for future neutrino mass experiments using this technique.

  16. Design Study Of Cyclotron Magnet With Permanent Magnet

    SciTech Connect

    Kim, Hyun Wook; Chai, Jong Seo

    2011-06-01

    Low energy cyclotrons for Positron emission tomography (PET) have been wanted for the production of radio-isotopes after 2002. In the low energy cyclotron magnet design, increase of magnetic field between the poles is needed to make a smaller size of magnet and decrease power consumption. The Permanent magnet can support this work without additional electric power consumption in the cyclotron. In this paper the study of cyclotron magnet design using permanent magnet is shown and also the comparison between normal magnet and the magnet which is designed with permanent magnet is shown. Maximum energy of proton is 8 MeV and RF frequency is 79.3 MHz. 3D CAD design was done by CATIA P3 V5 R18 and the All field calculations had been performed by OPERA-3D TOSCA. The self-made beam dynamics program OPTICY is used for making isochronous field and other calculations.

  17. a Small Low-Energy Cyclotron for Radioisotope Measurements.

    NASA Astrophysics Data System (ADS)

    Bertsche, Kirk Joseph

    Direct detection of ^{14} C by accelerator mass spectrometry has proved to be a much more sensitive method for radiocarbon dating than the decay counting method invented earlier by Libby. A small cyclotron (the "cyclotron") was proposed for direct detection of radiocarbon in 1980. This combined the suppression of background through the use of negative ions, which had been used effectively in tandem accelerators, with the high intrinsic mass resolution of a cyclotron. Development of a small electrostatically-focused cyclotron for use as a mass spectrometer was previously reported but the sensitivity needed for detection of ^{14 }C at natural abundance was not achieved. The major contributions of this work are the integration of a high current external ion source with a small flat -field, electrostatically-focused cyclotron to comprise a system capable of measuring ^{14 }C at natural levels, and the analysis of ion motion in such a cyclotron, including a detailed analysis of phase bunching and its effect on mass resolution. A high current cesium sputter negative ion source generates a beam of carbon ions which is pre-separated with a Wien filter and is transported to the cyclotron via a series of electrostatic lenses. Beam is injected radially into the cyclotron using electrostatic deflectors and an electrostatic mirror. Axial focusing is entirely electrostatic. A microchannel plate detector is used with a phase-gated output. In its present form the system is capable of improving the sensitivity of detecting ^{14} C in some biomedical experiments by a factor of 10^4. Modifications are discussed which could bring about an additional factor of 100 in sensitivity, which is important for archaeological and geological applications. Possibilities for measurements of other isotopes, such as ^3H, and ^{10}Be, and ^{26}Al, are discussed.

  18. Mirror and ion cyclotron anisotropy instabilities in the magnetosheath

    NASA Technical Reports Server (NTRS)

    Mckean, M. E.; Winske, D.; Gary, S. P.

    1992-01-01

    The kinetic properties of the ion cyclotron anisotropy and the mirror instabilities are investigated using one-dimensional hybrid simulations. It is found that, for moderate values of the ion beta and the proton temperature anisotropy, the two instabilities produce similar levels of turbulence. For high values of beta or temperature anisotropy, the ion cyclotron instability produces higher fluctuation levels of turbulence than does the mirror instability.

  19. PET computer programs for use with the 88-inch cyclotron

    SciTech Connect

    Gough, R.A.; Chlosta, L.

    1981-06-01

    This report describes in detail several offline programs written for the PET computer which provide an efficient data management system to assist with the operation of the 88-Inch Cyclotron. This function includes the capability to predict settings for all cyclotron and beam line parameters for all beams within the present operating domain of the facility. The establishment of a data base for operational records is also described from which various aspects of the operating history can be projected.

  20. Status and development of the Kazakhstan isochronous cyclotron

    NASA Astrophysics Data System (ADS)

    Arzumanov, A.; Batischev, V.; Borissenko, A.; Gorkovets, M.; Koptev, V.; Lyssukhin, S.; Mulgin, S.; Popov, Yu.; Zhdanov, S.

    2001-12-01

    A report is presented on the status of the cyclotron in Almaty at present time. In spite of sharp curtailment of government-funded basic research program the cyclotron still remains as multipurpose accelerator facility and is being used for fundamental research and application in different fields of applied science. During last years some cyclotron systems were upgraded and some were designed anew. The system for on-line precise ion beam energy measurement using time-of-flight method was designed and constructed. Inductive pick-up electrodes are integrated into beam transport channel and are located at the distance of 10 m from each other. Average beam energy determination is performed with the accuracy about 0.1%. This system allows to analyze ion beam parameters in pulse-mode of cyclotron operation with macro duty factor in the range of 2-50. In connection with development of cyclotron based radioisotope production and necessity of irradiation of toxic materials and loose and smelted powders with low heat conductivity circular beam scanning system was designed and installed. Transversal rotating magnetic field is generated by stator of usual electro-motor. The scanner allows to form predictable beam power density distribution on the target surface and obtain rather uniform irradiation fields. Cyclotron based neutron source with Be target for research on radioecology and neutron dosimetry was constructed and is located at one of the external beam transportation channel. Parameters of the system and examples of its application are presented.

  1. Ion source and injection line for high intensity medical cyclotron

    SciTech Connect

    Jia, XianLu Guan, Fengping; Yao, Hongjuan; Zhang, TianJue; Yang, Jianjun; Song, Guofang; Ge, Tao; Qin, Jiuchang

    2014-02-15

    A 14 MeV high intensity compact cyclotron, CYCIAE-14, was built at China Institute of Atomic Energy (CIAE). An injection system based on the external H− ion source was used on CYCIAE-14 so as to provide high intensity beam, while most positron emission tomography cyclotrons adopt internal ion source. A beam intensity of 100 μA/14 MeV was extracted from the cyclotron with a small multi-cusp H− ion source (CIAE-CH-I type) and a short injection line, which the H− ion source of 3 mA/25 keV H− beam with emittance of 0.3π mm mrad and the injection line of with only 1.2 m from the extraction of ion source to the medial plane of the cyclotron. To increase the extracted beam intensity of the cyclotron, a new ion source (CIAE-CH-II type) of 9.1 mA was used, with maximum of 500 μA was achieved from the cyclotron. The design and test results of the ion source and injection line optimized for high intensity acceleration will be given in this paper.

  2. Status report of the 28 GHz superconducting electron cyclotron resonance ion source VENUS (invited)

    SciTech Connect

    Leitner, D.; Lyneis, C.M.; Loew, T.; Todd, D.S.; Virostek, S.; Tarvainen, O.

    2006-03-15

    The superconducting versatile electron cyclotron resonance (ECR) ion source for nuclear science (VENUS) is a next generation superconducting ECR ion source designed to produce high-current, high-charge-state ions for the 88-Inch Cyclotron at the Lawrence Berkeley National Laboratory. VENUS also serves as the prototype ion source for the rare isotope accelerator (RIA) front end, where the goal is to produce intense beams of medium-charge-state ions. Example beams for the RIA accelerator are 15 p {mu}A of Kr{sup 17+}(260 e {mu}A), 12 p {mu}A of Xe{sup 20+} (240 e {mu}A of Xe{sup 20+}), and 8 p {mu}A of U{sup 28+}(230 e {mu}A). To achieve these high currents, VENUS has been optimized for operation at 28 GHz, reaching maximal confinement fields of 4 and 3 T axially and over 2.2 T on the plasma chamber wall radially. After a commissioning phase at 18 GHz, the source started the 28 GHz operation in the summer of 2004. During that ongoing 28 GHz commissioning process, record ion-beam intensities have been extracted. For instance, measured extracted currents for the low to medium charge states were 270 e {mu}A of Xe{sup 27+} and 245 e {mu}A of Bi{sup 29+}, while for the higher charge states 15 e {mu}A of Xe{sup 34+}, 15 e {mu}A of Bi{sup 41+}, and 0.5 e {mu}A of Bi{sup 50+} could be produced. Results from the ongoing 28 GHz commissioning as well as results using double-frequency heating with 18 and 28 GHz for oxygen and xenon are presented. The effect of the minimum B field on the ion source performance has been systematically measured for 18 and 28 GHz. In both cases the performance peaked at a minimum B field of about 80% of the resonance field. In addition, a strong dependence of the x-ray flux and energy on the minimum B field value was found.

  3. Status report of the 28 GHz superconducting electron cyclotron resonance ion source VENUS (invited)

    NASA Astrophysics Data System (ADS)

    Leitner, D.; Lyneis, C. M.; Loew, T.; Todd, D. S.; Virostek, S.; Tarvainen, O.

    2006-03-01

    The superconducting versatile electron cyclotron resonance (ECR) ion source for nuclear science (VENUS) is a next generation superconducting ECR ion source designed to produce high-current, high-charge-state ions for the 88-Inch Cyclotron at the Lawrence Berkeley National Laboratory. VENUS also serves as the prototype ion source for the rare isotope accelerator (RIA) front end, where the goal is to produce intense beams of medium-charge-state ions. Example beams for the RIA accelerator are 15 p μA of Kr17+(260 e μA), 12 p μA of Xe20+ (240 e μA of Xe20+), and 8 p μA of U28+(230 e μA). To achieve these high currents, VENUS has been optimized for operation at 28 GHz, reaching maximal confinement fields of 4 and 3 T axially and over 2.2 T on the plasma chamber wall radially. After a commissioning phase at 18 GHz, the source started the 28 GHz operation in the summer of 2004. During that ongoing 28 GHz commissioning process, record ion-beam intensities have been extracted. For instance, measured extracted currents for the low to medium charge states were 270 e μA of Xe27+ and 245 e μA of Bi29+, while for the higher charge states 15 e μA of Xe34+, 15 e μA of Bi41+, and 0.5 e μA of Bi50+ could be produced. Results from the ongoing 28 GHz commissioning as well as results using double-frequency heating with 18 and 28 GHz for oxygen and xenon are presented. The effect of the minimum B field on the ion source performance has been systematically measured for 18 and 28 GHz. In both cases the performance peaked at a minimum B field of about 80% of the resonance field. In addition, a strong dependence of the x-ray flux and energy on the minimum B field value was found.

  4. Clinical results of stereotactic hellium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory

    SciTech Connect

    Levy, R.P.; Fabrikant, J.I.; Lyman, J.T.; Frankel, K.A.; Phillips, M.H.; Lawrence, J.H.; Tobias, C.A.

    1989-12-01

    The first therapeutic clinical trial using accelerated heavy-charged particles in humans was performed at Lawrence Berkeley Laboratory (LBL) for the treatment of various endocrine and metabolic disorders of the pituitary gland, and as suppressive therapy for adenohypophyseal hormone-responsive carcinomas and diabetic retinopathy. In acromegaly, Cushing's disease, Nelson's syndrome and prolactin-secreting tumors, the therapeutic goal in the 433 patients treated has been to destroy or inhibit the growth of the pituitary tumor and control hormonal hypersecretion, while preserving a functional rim of tissue with normal hormone-secreting capacity, and minimizing neurologic injury. An additional group of 34 patients was treated for nonsecreting chromophobe adenomas. This paper discusses the methods and results of stereotactic helium-ion radiosurgery of the pituitary gland at Lawrence Berkeley Laboratory. 11 refs.

  5. A Community of Scientists and Educators: The Compass Project at UC Berkeley

    NASA Astrophysics Data System (ADS)

    Roth, Nathaniel; Schwab, Josiah

    2016-01-01

    The Berkeley Compass Project is a self-formed group of graduate and undergraduate students in the physical sciences at the University of California, Berkeley. Its goals are to improve undergraduate physics education, provide opportunities for professional development, and increase retention of students from populations underrepresented in the physical sciences. For undergraduate students, the core Compass experience consists of a summer program and several seminar courses. These programs are designed to foster a diverse, collaborative student community in which students engage in authentic research practices and regular self-reflection. Graduate students, together with upper-level undergraduates, design and run all Compass programs. Compass strives to incorporate best practices from the science education literature. Experiences in Compass leave participants poised to be successful students researchers, teachers, and mentors.

  6. The SEMATECH Berkeley microfield exposure tool: learning a the 22-nm node and beyond

    SciTech Connect

    Naulleau, Patrick; Anderson, Christopher; Baclea-an, Lorie-Mae; Denham, Paul; George, Simi; Goldberg, Kenneth A.; Goldstein, Michael; Hoef, Brian; Hudyma, Russ; Jones, Gideon; Koh, Chawon; La Fontaine, Bruno; McClinton, Brittany; Miyakawa, Ryan; Montgomery, Warren; Roller, John; Wallow, Tom; Wurm, Stefan

    2009-02-16

    Microfield exposure tools (METs) continue to playa dominant role in the development of extreme ultraviolet (EUV) resists. One of these tools is the SEMATECH Berkeley 0.3-NA MET operating as a SEMATECH resist and mask test center. Here we present an update summarizing the latest resist test and characterization results. The relatively small numerical aperture and limited illumination settings expected from 1st generation EUV production tools make resist resolution a critical issue even at the 32-nm node. In this presentation, sub 22 nm half pitch imaging results of EUV resists are reported. We also present contact hole printing at the 30-nm level. Although resist development has progressed relatively well in the areas of resolution and sensitivity, line-edge-roughness (LER) remains a significant concern. Here we present a summary of recent LER performance results and consider the effect of system-level contributors to the LER observed from the SEMA TECH Berkeley microfield tool.

  7. Latest results from the SEMATECH Berkeley extreme ultraviolet microfield exposure tool

    SciTech Connect

    Naulleau, Patrick; Anderson, Christopher N.; Chiu, Jerrin; Dean, Kim; Denham, Paul; George, Simi; Goldberg, Kenneth A.; Hoef, Brian; Jones, Gideon; Koh, Chawon; La Fontaine, Bruno; Ma, Andy; Montgomery, Warren; Niakoula, Dimitra; Park, Joo-On; Wallow, Tom; Wurm, Stefan

    2008-09-02

    Microfield exposure tools (METs) continue to play a dominant role in the development of extreme ultraviolet (EUV) resists. One of these tools is the 0.3 numerical aperture SEMATECH Berkeley MET operating as a resist and mask test center. Here they present an update on the tool summarizing some of the latest test and characterization results. they provide an update on the long-term aberration stability of the tool and present line-space imaging in chemically amplified photoresist down to the 20-nm half-pitch level. Although resist development has shown substantial progress in the area of resolution, line-edge-roughness (LER) remains a significant concern. Here we present a summary of recent LER performance results and consider the effect of mask contributors to the LER observed from the SEMATECH Berkeley microfield tool.

  8. Construction and operation of replacement hazardous waste handling facility at Lawrence Berkeley Laboratory. Environmental Assessment

    SciTech Connect

    Not Available

    1992-09-01

    The US Department of Energy (DOE) has prepared an environmental assessment (EA), DOE/EA-0423, for the construction and operation of a replacement hazardous waste handling facility (HWHF) and decontamination of the existing HWHF at Lawrence Berkeley Laboratory (LBL), Berkeley, California. The proposed facility would replace several older buildings and cargo containers currently being used for waste handling activities and consolidate the LBL`s existing waste handling activities in one location. The nature of the waste handling activities and the waste volume and characteristics would not change as a result of construction of the new facility. Based on the analysis in the EA, DOE has determined that the proposed action would not constitute a major Federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act (NEPA) of 1969, 42 USC. 4321 et seq. Therefore, an environmental impact statement is not required.

  9. A community of educators: professional development for graduate students within the Berkeley Compass Project

    NASA Astrophysics Data System (ADS)

    Schwab, Josiah; Roth, Nathaniel; Berkeley Compass Project

    2015-01-01

    The Berkeley Compass Project is a self-formed group of graduate and undergraduate students in the physical sciences at UC Berkeley. Our goals are to improve undergraduate physics education, provide opportunities for professional development, and increase retention of students from populations typically underrepresented in the physical sciences. Graduate students, together with upper-level undergraduates, design and run all Compass programs. We strive to create a community of educators that incorporates best practices from the science education literature. Along the way, we develop experience in curriculum development, fundraising, grant writing, interfacing with university administration, and other aspects of running an effective organization. Our experience in Compass leaves us better poised to be successful researchers, teachers, and mentors.

  10. Analytical representation of cyclotron magnetic field

    SciTech Connect

    Lee-Whiting, G.E.; Davies, W.G.

    1994-07-01

    A model has been developed for the rapid but accurate calculation of the static magnetic field in the Chalk River cyclotron. The field is expressed in terms of elementary functions which can be handled efficiently in differential-algebra trajectory integrations. Maxwell`s equations are satisfied exactly. Each of seven subdivisions of the superconducting coils is treated by a moment expansion about a central circle. Each pole is modeled as a uniformly magnetized semi-infinite prism. Monopoles and dipoles at the vertices of the polygonal pole faces correct for departures from the true pole shape. Uniform distributions of dipole strength along the edges of the pole-face polygons correct for the local inappropriateness of the assumption of uniform magnetization. The contributions of the yoke and of other relatively distant parts of the structure to the field in the region of particle acceleration are represented by low-order polynomials. Some of the source parameters are obtained by fitting to the measured values of B{sub z} in the horizontal plane of symmetry.

  11. Fourth generation electron cyclotron resonance ion sources.

    PubMed

    Lyneis, Claude M; Leitner, D; Todd, D S; Sabbi, G; Prestemon, S; Caspi, S; Ferracin, P

    2008-02-01

    The concepts and technical challenges related to developing a fourth generation electron cyclotron resonance (ECR) ion source with a rf frequency greater than 40 GHz and magnetic confinement fields greater than twice B(ECR) will be explored in this article. Based on the semiempirical frequency scaling of ECR plasma density with the square of operating frequency, there should be significant gains in performance over current third generation ECR ion sources, which operate at rf frequencies between 20 and 30 GHz. While the third generation ECR ion sources use NbTi superconducting solenoid and sextupole coils, the new sources will need to use different superconducting materials, such as Nb(3)Sn, to reach the required magnetic confinement, which scales linearly with rf frequency. Additional technical challenges include increased bremsstrahlung production, which may increase faster than the plasma density, bremsstrahlung heating of the cold mass, and the availability of high power continuous wave microwave sources at these frequencies. With each generation of ECR ion sources, there are new challenges to be mastered, but the potential for higher performance and reduced cost of the associated accelerator continues to make this a promising avenue for development. PMID:18315111

  12. 30-cm electron cyclotron plasma generator

    NASA Technical Reports Server (NTRS)

    Goede, Hank

    1987-01-01

    Experimental results on the development of a 30-cm-diam electron cyclotron resonance plasma generator are presented. This plasma source utilizes samarium-cobalt magnets and microwave power at a frequency of 4.9 GHz to produce a uniform plasma with densities of up to 3 x 10 to the 11th/cu cm in a continuous fashion. The plasma generator contains no internal structures, and is thus inherently simple in construction and operation and inherently durable. The generator was operated with two different magnetic geometries. One used the rare-earth magnets arranged in an axial line cusp configuration, which directly showed plasma production taking place near the walls of the generator where the electron temperature was highest but with the plasma density peaking in the central low B-field regions. The second configuration had magnets arranged to form azimuthal line cusps with approximately closed electron drift surfaces; this configuration showed an improved electrical efficiency of about 135 eV/ion.

  13. The irradiation facility at the AGOR cyclotron

    NASA Astrophysics Data System (ADS)

    Brandenburg, Sytze; Ostendorf, Reint; Hofstee, Mariet; Kiewiet, Harry; Beijers, Hans

    2007-08-01

    The KVI is conducting radiobiology research using protons up to 190 MeV from the superconducting AGOR cyclotron in collaboration with the University Medical Center Groningen (UMCG) since 1998. Using the same set-up, we have started irradiations for radiation hardness studies of detectors and components for the European Space Agency (ESA) and industrial parties. For these irradiations, we use either mono-energetic protons or a simulated solar flare energy spectrum with fluxes up to 5 × 108 protons cm-2 s-1. Furthermore, tests of radiation effects such as single event upsets, are being performed with intensities down to a few particles/s. Different energies are achieved by degrading the primary beam energy. We are currently developing the capability for heavy ion irradiations in air with beams up to Xe at beam energies between 15 and 45 MeV per nucleon. Performing the irradiations in air simplifies handling and monitoring of the device under test. The high energy allows penetration to the active layer of electronic devices, without modifications to the chip housing. The different ions provide a wide range in LET.

  14. The Oak Ridge Isochronous Cyclotron Refurbishment Project

    SciTech Connect

    Mendez, II, Anthony J; Ball, James B; Dowling, Darryl T; Mosko, Sigmund W; Tatum, B Alan

    2011-01-01

    The Oak Ridge Isochronous Cyclotron (ORIC) has been in operation for nearly fifty years at the Oak Ridge National Laboratory (ORNL). Presently, it serves as the driver accelerator for the ORNL Holifield Radioactive Ion Beam Facility (HRIBF), where radioactive ion beams are produced using the Isotope Separation Online (ISOL) technique for post-acceleration by the 25URC tandem electrostatic accelerator. Operability and reliability of ORIC are critical issues for the success of HRIBF and have presented increasingly difficult operational challenges for the facility in recent years. In February 2010, a trim coil failure rendered ORIC inoperable for several months. This presented HRIBF with the opportunity to undertake various repairs and maintenance upgrades aimed at restoring the full functionality of ORIC and improving the reliability to a level better than what had been typical over the previous decade. In this paper, we present details of these efforts, including the replacement of the entire trim coil set and measurements of their radial field profile. Comparison of measurements and operating tune parameters with setup code predictions will also be presented.

  15. Progress Report on the Berkeley/Anglo-Australian Observatory High-redshift Supernova Search

    DOE R&D Accomplishments Database

    Goldhaber, G.; Perlmutter, S.; Pennypacker, C.; Marvin, H.; Muller, R. A.; Couch, W.; Boyle, B.

    1990-11-01

    There are two main efforts related to supernovae in progress at Berkeley. The first is an automated supernova search for nearby supernovae, which was already discussed by Carl Pennypacker at this conference. The second is a search for distant supernovae, in the z = 0.3 to 0.5 region, aimed at measuring {Omega}. It is the latter that I want to discuss in this paper.

  16. Gilbert Newton Lewis: his influence on physical-organic chemists at Berkeley

    SciTech Connect

    Calvin, M.

    1982-03-01

    A review is presented of the historical contributions of Gilbert N. Lewis to science and a discussion of the influence of Lewis on the research of the members of the physical-organic staff at Berkeley, including Melvin Calvin, during the twenties, thirties and forties. Some specific examples are discussed. Also, the effect of Lewis, his science and administrative concepts in the creation of excellence in a department of chemistry are reviewed.

  17. Wetlands, Microbes, and the Carbon Cycle: Behind the Scenes @ Berkeley Lab

    ScienceCinema

    Tringe, Susannah

    2013-05-29

    Susannah Tringe, who leads the Metagenome Program at the Department of Energy's Joint Genome Institute (JGI), a collaboration in which Berkeley Lab plays a leading role, takes us behind the scenes to show how DNA from unknown wild microbes is extracted and analyzed to see what role they play in the carbon cycle. Tringe collects samples of microbial communities living in the wetland muck of the Sacramento-San Joaquin River Delta, organisms that can determine how these wetlands store or release carbon.

  18. The Berkeley Instrumental Neutron Generator (BINGE) for 40Ar/39Ar geochronology

    NASA Astrophysics Data System (ADS)

    Renne, P. R.; Becker, T. A.; Bernstein, L.; Firestone, R. B.; Kirsch, L.; Leung, K. N.; Rogers, A.; Van Bibber, K.; Waltz, C.

    2014-12-01

    The Berkeley Instrumental Neutron Generator (BINGE) facility is the product of a consortium involving the Berkeley Geochronology Center (BGC), the U.C. Berkeley Nuclear Engineering Dept. (UCB/NE), and Lawrence Berkeley (LBNL) and Lawrence Livermore (LLNL) National Labs. BINGE was initially designed (and funded by NSF) for 40Ar/39Ar geochronology. BINGE uses a plasma-based deuteron ion source and a self-loading Ti-surfaced target to induce deuteron-deuterium (DD) fusion via the reaction 2H(d,n)3He, producing 2.45 MeV neutrons. The limited neutron energy spectrum is aimed at reducing recoil effects, interfering nuclear reactions, and unwanted radioactive byproducts, all of which are undesirable consequences of conventional irradiation with 235U fission spectrum neutrons. Minimization of interfering reactions such as 40Ca(n,na)36Ar greatly reduces penalties for over-irradiation, enabling improved signal/background measurement of e.g. 39Ar. BINGE will also be used for a variety of nuclear physics and engineering experiments that require a high flux of monoenergetic neutrons. Neutron energies lower than 2.45 MeV can be obtained via irradiation ports within and external to polyethylene shielding. Initial commissioning produced a neutron flux of 108 n/sec/cm2 at 1 mA source current and 100 kV anode voltage, as expected. When scaled up to the 1 A source current as planned, this indicates that BINGE will achieve the design objective neutron flux of 1011 n/sec/cm2. Further progress towards this goal will be reported. Supported by NSF (grant #EAR-0960138), BGC, UCB/NE, University of California Office of the President, and DOE through LLNL under contract #DE-AC52-07NA27344 and LBNL under contract #DE-AC02-05CH11231.

  19. CIRCE, the Proposed Coherent Infrared Center at the LawrenceBerkeley National Laboratory

    SciTech Connect

    Byrd, John M.; Martin, Michael M.; Sannibale, Fernando

    2005-07-12

    At the Advanced Light Source (ALS) of the Lawrence Berkeley National Laboratory (LBNL), we are proposing the construction of CIRCE (Coherent InfraRed Center), a ring-based photon source completely optimized for the generation of coherent synchrotron radiation (CSR) in the terahertz frequency range [1]. CIRCE exploits the full complement of the CSR-production mechanisms presently available for obtaining top performance, including a photon flux exceeding by more than nine orders of magnitude that of existing ''conventional'' broadband terahertz sources.

  20. Wetlands, Microbes, and the Carbon Cycle: Behind the Scenes @ Berkeley Lab

    SciTech Connect

    Tringe, Susannah

    2012-01-01

    Susannah Tringe, who leads the Metagenome Program at the Department of Energy's Joint Genome Institute (JGI), a collaboration in which Berkeley Lab plays a leading role, takes us behind the scenes to show how DNA from unknown wild microbes is extracted and analyzed to see what role they play in the carbon cycle. Tringe collects samples of microbial communities living in the wetland muck of the Sacramento-San Joaquin River Delta, organisms that can determine how these wetlands store or release carbon.

  1. The Berkeley EUV/FUV Shuttle Telescope - Observations of dust reflection in the FUV

    NASA Technical Reports Server (NTRS)

    Hurwitz, Mark; Martin, Christopher; Bowyer, Stuart

    1986-01-01

    Observations by the Berkeley EUV/FUV Shuttle Telescope of the FUV reflection from dust clouds are reported. Spectra of the diffuse UV background from regions of low and high hydrogen column density have been taken. The intensity of the continuum correlates well with the column density of neutral hydrogen, and the slope of this correlation is interpreted with a simple model of optically thin scattering to obtain a measurement of a combination of the albedo and asymmetry parameter in the FUV.

  2. Nuclear Science and Physics Data from the Isotopes Project, Lawrence Berkeley National Laboratory (LBNL)

    DOE Data Explorer

    The Isotopes Project pages at Lawrence Berkeley National Laboratory have been a source of nuclear data and reference information since the mid-nineties. Almost all of the data, the results of analyses, the specialized charts and interfaces, and the extensive bibiographic references are fed to the National Nuclear Data Center (NNDC) at Brookhaven National Laboratory and maintained there. The Isotope Project pages at LBNL provide a glimpse of early versions for many of the nuclear data resources.

  3. Inclusion of the electron-phonon interaction in the BerkeleyGW computational package

    NASA Astrophysics Data System (ADS)

    Vigil-Fowler, Derek; Lany, Stephan

    The BerkeleyGW package is a highly optimized and efficient code for calculating, among others, the dielectric response, bandstructures, lifetimes, and optical absorption of materials from nanostructures and two-dimensional sheets to bulk materials. In the past the only interactions included in BerkeleyGW were electron-electron interactions, with other packages being used to include the effect of, say, electron-phonon interactions. One common approach is to use Wannier functions to interpolate all needed quantities to a very fine grids in energy and momentum, which leads to very accurate electron-phonon couplings and lifetimes. However, in materials with complex, even unknown, chemical environments the generation of Wannier functions can be quite time consuming and constitutes another step in an already difficult calculation. The BerkeleyGW package has a wavefunction-based interpolation scheme that is used in solving the Bethe-Salpeter equation and which is much more easily automated than Wannier interpolation. In this talk, we discuss results for the carrier lifetimes due to the electron-phonon interaction using this interpolation scheme. In particular, we discuss the computational efficiency and scalability, and the prospects for applying this method to a wide range of materials to get first principles lifetimes, and related quantities, such as mobilities and diffusion lengths. Derek Vigil-Fowler's work is supported by the National Renewable Energy Laboratory's Director's Postdoctoral Fellowship.

  4. The Society for Women in the Physical Sciences: a successful mentoring program at UC Berkeley

    NASA Astrophysics Data System (ADS)

    Lang, Kristine

    2000-04-01

    The Society for Women in the Physical Sciences (SWPS, http://socrates.berkeley.edu/ swps) at the University of California at Berkeley has been up and running successfully for three years. This organization aims to increase the number of women undergrad majors in physics, astronomy, and geology and to foster a general sense of community among all the women in these departments: faculty, postdocs, and students. The program consists of three parts: mentoring, events, and resources. The mentoring portion pairs 4 to 5 undergraduate women with one graduate mentor. These mentoring groups meet approximately weekly to visit labs, work on homework, go to science museums, or just talk and gather ideas from one another. SWPS also organizes monthly events that include all members of the department and which have in the past been social events, workshops, or discussion forums. Finally, SWPS writes and distributes, on paper and on our website, a series of guides which make “informal” information, such as where are the quiet places to study, more easily available. During this talk I will present more of the details of this program. In addition, I will present anecdotal and quantitative results of the program at Berkeley and discuss how this program has been implemented at other universities. Finally, I will discuss the general strategies behind the program and how they can be applied to other programs aimed at women in science.

  5. A small low energy cyclotron for radioisotope measurements

    SciTech Connect

    Bertsche, K.J.

    1989-11-01

    Direct detection of {sup 14}C by accelerator mass spectrometry has proved to be a much more sensitive method for radiocarbon dating than the decay counting method invented earlier by Libby. A small cyclotron (the cyclotrino'') was proposed for direct detection of radiocarbon in 1980. This combined the suppression of background through the use of negative ions, which had been used effectively in tandem accelerators, with the high intrinsic mass resolution of a cyclotron. Development of a small electrostatically-focused cyclotron for use as a mass spectrometer was previously reported but the sensitivity needed for detection of {sup 14}C at natural abundance was not achieved. The major contributions of this work are the integration of a high current external ion source with a small flat-field, electrostatically-focused cyclotron to comprise a system capable of measuring {sup 14}C at natural levels, and the analysis of ion motion in such a cyclotron, including a detailed analysis of phase bunching and its effect on mass resolution. A high current cesium sputter negative ion source generates a beam of carbon ions which is pre-separated with a Wien filter and is transported to the cyclotron via a series of electrostatic lenses. Beam is injected radially into the cyclotron using electrostatic deflectors and an electrostatic mirror. Axial focusing is entirely electrostatic. A microchannel plate detector is used with a phase-grated output. In its present form the system is capable of improving the sensitivity of detecting {sup 14}C in some biomedical experiments by a factor of 10{sup 4}. Modifications are discussed which could bring about an additional factor of 100 in sensitivity, which is important for archaeological and geological applications. Possibilities for measurements of other isotopes, such as {sup 3}H, and {sup 10}Be, and {sup 26}Al, are discussed. 70 refs.

  6. Hayward Fault rate constraints at Berkeley: Evaluation of the 335-meter Strawberry Creek offset

    NASA Astrophysics Data System (ADS)

    Williams, P. L.

    2007-12-01

    At UC Berkeley the active channel of Strawberry Creek is offset 335 meters by the Hayward fault and two abandoned channels of Strawberry Creek are laterally offset 580 and 730 meters. These relationships record the displacement of the northern Hayward fault at Berkeley over a period of tens of millennia. The Strawberry Creek site has a similar geometry to the central San Andreas fault's Wallace Creek site, which arguably provides the best geological evidence of "millennial" fault kinematics in California (Sieh and Jahns, 1984). Slip rate determinations are an essential component of overall hazard evaluation for the Hayward fault, and this site is ripe to disclose a long-term form of this parameter, to contrast with geodetic and other geological rate evidence. Large offsets at the site may lower uncertainty in the rate equation relative to younger sites, as the affect of stream abandonment age, generally the greatest source of rate uncertainty, is greatly reduced. This is helpful here because it more-than-offsets uncertainties resulting from piercing projections to the fault. Strawberry Creek and its ancestral channels suggest west-side-up vertical deformation across the Hayward fault at this location. The development of the vertical deformation parameter will complement ongoing geodetic measurements, particularly InSAR, and motivate testing of other geological constraints. Up-to-the-west motion across the Hayward fault at Berkeley has important implications for the partitioning of strain and kinematics of the northern Hayward fault, and may explain anomalous up-on-the-west landforms elsewhere along the fault. For example, geological features of the western Berkeley Hills are consistent with rapid and recent uplift to the west of the fault. On the basis of a preliminary analysis of the offset channels of Strawberry Creek, up-to-the-west uplift is about 0.5mm/yr across the Hayward fault at Berkeley. If this is in fact the long-term rate, the 150 m height of the Hills

  7. Environmental assessment for the proposed construction and operation of a Genome Sequencing Facility in Building 64 at Lawrence Berkeley Laboratory, Berkeley, California

    SciTech Connect

    1995-04-01

    This document is an Environmental Assessment (EA) for a proposed project to modify 14,900 square feet of an existing building (Building 64) at Lawrence Berkeley Laboratory (LBL) to operate as a Genome Sequencing Facility. This EA addresses the potential environmental impacts from the proposed modifications to Building 64 and operation of the Genome Sequencing Facility. The proposed action is to modify Building 64 to provide space and equipment allowing LBL to demonstrate that the Directed DNA Sequencing Strategy can be scaled up from the current level of 750,000 base pairs per year to a facility that produces over 6,000,000 base pairs per year, while still retaining its efficiency.

  8. Relativistic Cyclotron Resonance Shape in Magnetic Bottle Geonium

    NASA Astrophysics Data System (ADS)

    Dehmelt, Hans; Mittleman, Richard; Liu, Yuan

    1988-10-01

    The thermally excited axial oscillation of the electron through the weak magnetic bottle needed for the continuous Stern-Gerlach effect modulates the cyclotron frequency and produces a characteristic ≈ 12-kHz-wide vertical rise-exponential decline line shape of the cyclotron resonance. At the same time the relativistic mass shift decreases the frequency by ≈ 200 Hz per cyclotron motion quantum level n. Nevertheless, our analysis of the complex line shape shows that it should be possible to produce an abrupt rise in the cyclotron quantum number n from 0 to ≈ 20 over a small fraction of 200 Hz, when the 160-GHz microwave drive approaches the n = 0 → 1 transition, and a jump of 14 levels over a frequency increment of 200 Hz has already been observed in preliminary work. This realizes an earlier proposal to generate a very sharp cyclotron resonance feature by quasithermal excitation with a square noise band and should provide a way to detect spin flips when a weak bottle is used to reduce the broadening of the g - 2 resonance by a factor of 20.

  9. Cyclotron targets and production technologies used for radiopharmaceuticals in NPI

    NASA Astrophysics Data System (ADS)

    Fišer, M.; Kopička, K.; Hradilek, P.; Hanč, P.; Lebeda, O.; Pánek, J.; Vognar, M.

    2003-01-01

    This paper deals with some technical aspects of the development and production of cyclotronmade radiopharmaceuticals (excluding PET). In this field, nuclear chemistry and pharmacy are in a close contact; therefore, requirements of the both should be taken into account. The principles of cyclotron targetry, separation/recovery of materials and synthesis of active substances are given, as well as issues connected with formulation of pharmaceutical forms. As the radiopharmaceuticals should fulfil the requirements on in vivo preparations, there exist a variety of demands pertaining to Good Manufacturing Practice (GMP) concept, which is also briefly discussed. A typical production chain is presented and practical examples of real technologies based on cyclotron-made radionuclides are given as they have been used in Nuclear Physics Institute of CAS (NPI). Special attention is devoted to the technology of enriched cyclotron targets. Frequently used medicinal products employing cyclotron-produced active substances are characterised (Rb/Kr generators, 123I-labelled MIBG, OIH and MAB's). The cyclotron produced radioactive implants for transluminal coronary angioplasty (radioactive stents) are introduced as an example of a medical device developed for therapeutic application.

  10. Generation of Electromagnetic Bursts in the Plasma Cyclotron Maser

    NASA Astrophysics Data System (ADS)

    Viktorov, M. E.; Vodopyanov, A. V.; Golubev, S. V.; Izotov, I. V.; Mansfeld, D. A.

    2013-06-01

    We study experimentally the frequency and energy characteristics of electromagnetic waves in the plasma cyclotron maser, where the active medium is the two-component nonequilibrium plasma of an electron cyclotron resonance (ECR) discharge, which is produced by a high-power gyrotron radiation in a mirror trap. At the plasma decay stage, high-power (up to 200 W) pulses of electromagnetic radiation are detected synchronously with the precipitation of energetic electrons from the trap. This radiation propagates across the magnetic trap, and the radiation frequency fits in the interval between the electron gyrofrequency at the center of the mirror and the frequency of the electron cyclotron resonance heating. Synchronicity of the generated radiation with the electron precipitation out of the trap, as well as the dependence of the radiation frequency on the magnetic field of the trap, confirm the cyclotron mechanism of the arising instability. It is shown that electron precipitation, which is due to the cyclotron instability of the low-density plasma, ensures fast relaxation (as compared with the loss due to the Coulomb collisions) of the energy stored in the hot component of the plasma.

  11. Electrostatic electron cyclotron harmonic instability near Ganymede

    NASA Astrophysics Data System (ADS)

    Tripathi, A. K.; Singhal, R. P.; Singh, K. P.; Singh, O. N.

    2014-08-01

    Jupiter's moon—Ganymede—is the largest satellite in our solar system. Galileo spacecraft made six close flybys to explore Ganymede. More information was acquired about particle population, magnetic field and plasma waves during these encounters. In this paper, our aim is to study the generation of electrostatic electron cyclotron harmonic (ECH) emissions in the vicinity of Ganymede using the observed particle data. The calculated ECH wave's growth rates are analyzed in the light of observations of plasma waves along the path of Galileo near Ganymede. Dispersion relation for electrostatic mode is solved to obtain the temporal growth rates. A new electron distribution function, fitted to distribution observed near Ganymede, is used in the calculations. A parametric study is performed to evaluate the effect of loss-cone angle and the ratio of plasma to gyro-frequency on growth rates. It is found that ECH waves growth rates generally decrease as the loss-cone angle is increased. However, the ratio plasma to gyro-frequency has almost no effect on the growth rates. These parameters vary considerably along the Galileo trajectory near Ganymede. This is the first study which relates the occurrence of ECH waves with the particle and magnetic field data in the vicinity of Ganymede. The study of ECH wave growth rate near Ganymede is important for the calculation of pitch angle scattering rates of low-energy electrons and their subsequent precipitation into the thin atmosphere of Ganymede producing ultraviolet emissions. Results of the present study may also be relevant for the upcoming JUNO and JUICE missions to Jupiter.

  12. Issues in the analysis and interpretation of cyclotron lines in gamma ray bursts

    NASA Technical Reports Server (NTRS)

    Lamb, D. Q.

    1992-01-01

    The Bayesian approach is discussed to establishing the existence of lines, the importance of observing multiple cyclotron harmonics in determining physical parameters from the lines, and evidence from cyclotron lines of neutron star rotation.

  13. Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

    SciTech Connect

    Bhattacharjee, Tanushyam; Kanti Dey, Malay; Dhara, Partha; Roy, Suvodeep; Debnath, Jayanta; Balakrishna Bhole, Rajendra; Dutta, Atanu; Pradhan, Jedidiah; Pal, Sarbajit; Pal, Gautam; Roy, Amitava; Chakrabarti, Alok

    2013-05-15

    In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

  14. Precision phase control for the radio frequency system of K500 superconducting cyclotron at Variable Energy Cyclotron Centre, Kolkata

    NASA Astrophysics Data System (ADS)

    Som, Sumit; Ghosh, Surajit; Seth, Sudeshna; Mandal, Aditya; Paul, Saikat; Roy, Suprakash

    2013-11-01

    Variable Energy Cyclotron Centre (VECC) has commissioned K500 Superconducting cyclotron (SCC) based on MSU and Texas A&M university cyclotrons. The radio frequency (RF) system of SCC has been commissioned with the stringent requirement of various RF parameters. The three-phase RF system of Superconducting cyclotron has been developed in the frequency range 9-27 MHz with amplitude and phase stability of 100 ppm and ±0.1°, respectively. The phase control system has the option to change the relative phase difference between any two RF cavities and maintain the phase stability within ±0.1° during round-the-clock cyclotron operation. The said precision phase loop consists of both analogue In-phase/Quadrature modulator to achieve faster response and also Direct Digital Synthesis based phase shifter to achieve wide dynamic range as well. This paper discusses detail insights into the various issues of phase control for the K500 SCC at VECC, Kolkata.

  15. Precision phase control for the radio frequency system of K500 superconducting cyclotron at Variable Energy Cyclotron Centre, Kolkata

    SciTech Connect

    Som, Sumit; Ghosh, Surajit; Seth, Sudeshna; Mandal, Aditya; Paul, Saikat; Roy, Suprakash

    2013-11-15

    Variable Energy Cyclotron Centre (VECC) has commissioned K500 Superconducting cyclotron (SCC) based on MSU and Texas A and M university cyclotrons. The radio frequency (RF) system of SCC has been commissioned with the stringent requirement of various RF parameters. The three-phase RF system of Superconducting cyclotron has been developed in the frequency range 9–27 MHz with amplitude and phase stability of 100 ppm and ±0.1°, respectively. The phase control system has the option to change the relative phase difference between any two RF cavities and maintain the phase stability within ±0.1° during round-the-clock cyclotron operation. The said precision phase loop consists of both analogue In-phase/Quadrature modulator to achieve faster response and also Direct Digital Synthesis based phase shifter to achieve wide dynamic range as well. This paper discusses detail insights into the various issues of phase control for the K500 SCC at VECC, Kolkata.

  16. Cyclotron-resonance maser in a magnetic mirror.

    PubMed

    Caspi, R; Jerby, E

    1999-08-01

    A cyclotron-resonance maser (CRM) experiment is performed in a high-gradient magnetic field using a low-energy electron beam ( approximately 10 keV/1 A). The magnetic field exceeds 1.63 T, which corresponds to a 45-GHz cyclotron frequency. The CRM radiation output is observed in much lower frequencies, between 6.6 and 20 GHz only. This discrepancy is explained by the finite penetration depth of the electrons into the growing magnetic field, as in a magnetic mirror. The electrons emit radiation at the local cyclotron frequency in their reflection point from that magnetic mirror; hence, the radiation frequency depends mostly on the initial electron energy. A conceptual reflex gyrotron scheme is proposed in this paper, as a CRM analogue for the known reflex klystron. PMID:11970042

  17. Spectra and Neutron Dosimetry Inside a PET Cyclotron Vault Room

    SciTech Connect

    Vega-Carrillo, Hector Rene; Mendez, Roberto; Iniguez, Maria Pilar; Marti-Climent, Joseph; Penuelas, Ivan; Barquero, Raquel

    2006-09-08

    The neutron field around a PET cyclotron was investigated during 18F radioisotope production with an 18 MeV proton beam. Pairs of thermoluminescent dosemeters, TLD600 and TLD700, were used as thermal neutron detector inside a Bonner Spheres Spectrometer to measure the neutron spectra at three different positions inside the cyclotron's vault room. Neutron spectra were also determined by Monte Carlo calculations. The hardest spectrum was observed in front of cyclotron target and the softest was noticed at the antipode of target. Neutron doses derived from the measured spectra vary between 11 and 377 mSv/{mu}A-h of proton integrated current, Doses were also measured with a single-moderator remmeter, with an active thermal neutron detector, whose response in affected by the radiation field in the vault room.

  18. Proton and helium cyclotron anisotropy instability thresholds in the magnetosheath

    NASA Technical Reports Server (NTRS)

    Gary, S. Peter; Convery, Patrick D.; Denton, Richard E.; Fuselier, Stephen A.; Anderson, Brian J.

    1994-01-01

    Both the protons and the helium ions of the terrestrial magnetosheath typically display T (sub perpendicular) greater than T (sub parallel), where perpendicular to and parallel to denote directions perpendicular and parallel to the background magnetic field. Observations of the highly compressed magnetosheath show an inverse correlation between these ion temperature anisotropies and the parallel proton beta. Computer simulations have demonstrated that these correlations are due to wave-particle scattering by electromagnetic ion cyclotron anisotropy instabilities. These correlations correspond to linear theory thresholds of the proton cyclotron and the helium cyclotron instabilities. This paper uses linear Vlasov theory and the assumption of a constant maximum growth rate to obtain closed-form expressions for these thresholds as a function of the relative helium density and the parallel proton beta in a parameter model of the magnetosheath.

  19. A laboratory study of collisional electrostatic ion cyclotron waves

    NASA Technical Reports Server (NTRS)

    Suszcynsky, D. M.; Cartier, S. L.; Merlino, R. L.; Dangelo, N.

    1986-01-01

    The effects of neutral-particle collisions on electrostatic ion cyclotron instability are analyzed. Experiments were conducted in the Q machine of Motley (1975) with a cesium plasma in which the neutral gas pressure in the main chamber varied from about 5 microtorr-10 mtorr. The relation between electrostatic ion cyclotron wave amplitude and frequency and neutral argon pressure is examined. It is observed that over the full range of neutral pressure the frequency changes by less than 10 percent and the ion cyclotron waves continue to be excited and reach amplitudes of at least several percent at values of the neutral pressure where the ion-neutral collision frequency/ion gyrofrequency is about 0.3.

  20. Design study of the KIRAMS-430 superconducting cyclotron magnet

    NASA Astrophysics Data System (ADS)

    Kim, Hyun Wook; Kang, Joonsun; Hong, Bong Hwan; Jung, In Su

    2016-07-01

    Design study of superconducting cyclotron magnet for the carbon therapy was performed at the Korea Institute of Radiological and Medical Science (KIRAMS). The name of this project is The Korea Heavy Ion Medical Accelerator (KHIMA) project and a fixed frequency cyclotron with four spiral sector magnet was one of the candidate for the accelerator type. Basic parameters of the cyclotron magnet and its characteristics were studied. The isochronous magnetic field which can guide the 12C6+ ions up to 430 MeV/u was designed and used for the single particle tracking simulation. The isochronous condition of magnetic field was achieved by optimization of sector gap and width along the radius. Operating range of superconducting coil current was calculated and changing of the magnetic field caused by mechanical deformations of yokes was considered. From the result of magnetic field design, structure of the magnet yoke was planned.

  1. A new 14 GHz Electron-Cyclotron-Resonance Ion Source (ECRIS) for the heavy ion accelerator facility ATLAS

    SciTech Connect

    Schlapp, M.; Pardo, R.C.; Vondrasek, R.C.; Billquist, P.J.; Szczech, J.

    1997-11-01

    A 14 GHz Electron-Cyclotron-Resonance Ion Source (ECRIS) has been designed and built at Argonne National Laboratory. The source is a modification of the AECR at Berkeley and incorporates the latest results from ECR developments to produce intense beams of highly charged ions, including an improved magnetic confinement of the plasma electrons with an axial mirror ratio of 3.5. The aluminum plasma chamber and extraction electrode as well as a biased disk on axis at the microwave injection side donates additional electrons to the plasma, making use of the large secondary electron yield from aluminum oxide. The source is capable of ECR plasma heating using two different frequencies simultaneously to increase the electron energy gain for the production of high charge states. The main design goal is to produce several e{mu}A of at least {sup 238}U{sup 35+} in order to accelerate the beam to coulomb-barrier energies without further stripping. First charge state distributions for gaseous elements have been measured and 210 e{mu}A {sup 16}O{sup 7+} has been achieved. A normalized 90% emittance from 0.1 to 0.2 {pi} mm{sm_bullet}mrad for krypton and oxygen beam has been found.

  2. Distribution of thermal neutron flux around a PET cyclotron.

    PubMed

    Ogata, Yoshimune; Ishigure, Nobuhito; Mochizuki, Shingo; Ito, Kengo; Hatano, Kentaro; Abe, Junichiro; Miyahara, Hiroshi; Masumoto, Kazuyoshi; Nakamura, Hajime

    2011-05-01

    The number of positron emission tomography (PET) examinations has greatly increased world-wide. Since positron emission nuclides for the PET examinations have short half-lives, they are mainly produced using on-site cyclotrons. During the production of the nuclides, significant quantities of neutrons are generated from the cyclotrons. Neutrons have potential to activate the materials around the cyclotrons and cause exposure to the staff. To investigate quantities and distribution of the thermal neutrons, thermal neutron fluxes were measured around a PET cyclotron in a laboratory associating with a hospital. The cyclotron accelerates protons up to 18 MeV, and the mean particle current is 20 μA. The neutron fluxes were measured during both 18F production and C production. Gold foils and thermoluminescent dosimeter (TLD) badges were used to measure the neutron fluxes. The neutron fluxes in the target box averaged 9.3 × 10(6) cm(-2) s(-1) and 1.7 × 10(6) cm(-2) s(-1) during 18F and 11C production, respectively. Those in the cyclotron room averaged 4.1 × 10(5) cm(-2) s(-1) and 1.2 × 10(5) cm(-2) s(-1), respectively. Those outside the concrete wall shielding were estimated as being equal to or less than ∼3 cm s, which corresponded to 0.1 μSv h(-1) in effective dose. The neutron fluxes outside the concrete shielding were confirmed to be quite low compared to the legal limit. PMID:21451309

  3. A 1D Model For Describing Ion Cyclotron Resonance Heating At Arbitrary Cyclotron Harmonics

    NASA Astrophysics Data System (ADS)

    Van Eester, Dirk; Lerche, Ernesto

    2011-12-01

    Both at low and higher cyclotron harmonics, properly accounting for finite Larmor radius effects is crucial in many ICRF heating scenario's creating high energy tails. The present paper discusses an extension of the 1D TOMCAT wave equation solver [1] to arbitrary harmonics and arbitrary wavelengths. Rather than adopting the particle position, the guiding center position is used as the independent variable when writing down an expression for the dielectric response that is suitable for numerical application. This choice of variable yields symmetric and intuitive expressions, and guarantees that a positive definite power absorption is obtained for any of the wave modes in the plasma. Rather than relying on a truncated Taylor series expansion of the dielectric response, an integro-differential approach is proposed. To keep the required computation time for this generalized description reasonable tabulation of integrals is intensively used. An example is provided to illustrate the potential of the new wave code.

  4. A 600 MeV cyclotron for radioactive beam production

    SciTech Connect

    Clark, D.J.

    1993-05-17

    The magnetic field design for a 600 MeV proton cyclotron is described. The cyclotron has a single stage, a normal conducting magnet coil and a 9.8 m outside yoke diameter. It has 8 sectors, with a transition to 4 sectors in the center region. The magnetic field design was done using 1958 Harwell rectangular ridge system measurements and was compared with recent 3-dimensional field calculations with the program TOSCA at NSCL. The center region 4--8 sector transition focussing was also checked with TOSCA.

  5. N-bursty emission from Uranus: A cyclotron maser source?

    NASA Technical Reports Server (NTRS)

    Curran, D. B.; Menietti, J. D.

    1993-01-01

    Ray tracing studies of RX-mode emission from the north polar regions of Uranus indicate that the n-bursty radio emission may have a source along field lines with footprints near the northern magnetic pole (perhaps in the cusp), but not necessarily associated with regions of strong UV emission. This is in contrast with similar studies for the Uranus nightside smooth radio emission, which are believed to be due to the cyclotron maser instability. Source regions can be found for both hollow and filled emission cones and for frequencies well above the local gyrofreuquency implying that mechanisms other than the cyclotron maser mechanism may be operating.

  6. Fluid equations in the presence of electron cyclotron current drive

    SciTech Connect

    Jenkins, Thomas G.; Kruger, Scott E.

    2012-12-15

    Two-fluid equations, which include the physics imparted by an externally applied radiofrequency source near electron cyclotron resonance, are derived in their extended magnetohydrodynamic forms using the formalism of Hegna and Callen [Phys. Plasmas 16, 112501 (2009)]. The equations are compatible with the closed fluid/drift-kinetic model developed by Ramos [Phys. Plasmas 17, 082502 (2010); 18, 102506 (2011)] for fusion-relevant regimes with low collisionality and slow dynamics, and they facilitate the development of advanced computational models for electron cyclotron current drive-induced suppression of neoclassical tearing modes.

  7. A new injector for the ISL-cyclotron at HMI

    NASA Astrophysics Data System (ADS)

    Engels, O.; Häuser, J.; Homeyer, H.; Marhauser, F.; Pelzer, W.; Schempp, A.

    1996-06-01

    A new injector for the ISL (Ionen-Strahl-Labor) heavy ion cyclotron at the HMI (Hahn-Meitner-Institut) Berlin (the former VICKSI machine) is under construction, which uses an RFQ as an injector for a SSC (Separated-Sector-Cyclotron). The ECR source together with two variable energy 4-rod-RFQs will replace the Tandem injector to mett the demands of the solid state physics users. The design of the new RFQ injector and the status of the project will be discussed.

  8. Electron cyclotron current drive efficiency in general tokamak geometry

    SciTech Connect

    Lin-Liu, Y. R.; Chan, V. S.; Prater, R.

    2003-01-01

    Green's-function techniques are used to calculate electron cyclotron current drive (ECCD) efficiency in general tokamak geometry in the low-collisionality regime. Fully relativistic electron dynamics is employed in the theoretical formulation. The high-velocity collision model is used to model Coulomb collisions and a simplified quasi-linear rf diffusion operator describes wave-particle interactions. The approximate analytic solutions which are benchmarked with a widely used ECCD model, facilitate time-dependent simulations of tokamak operational scenarios using the non-inductive current drive of electron cyclotron waves.

  9. Single-Electron Detection and Spectroscopy via Relativistic Cyclotron Radiation.

    PubMed

    Asner, D M; Bradley, R F; de Viveiros, L; Doe, P J; Fernandes, J L; Fertl, M; Finn, E C; Formaggio, J A; Furse, D; Jones, A M; Kofron, J N; LaRoque, B H; Leber, M; McBride, E L; Miller, M L; Mohanmurthy, P; Monreal, B; Oblath, N S; Robertson, R G H; Rosenberg, L J; Rybka, G; Rysewyk, D; Sternberg, M G; Tedeschi, J R; Thümmler, T; VanDevender, B A; Woods, N L

    2015-04-24

    It has been understood since 1897 that accelerating charges must emit electromagnetic radiation. Although first derived in 1904, cyclotron radiation from a single electron orbiting in a magnetic field has never been observed directly. We demonstrate single-electron detection in a novel radio-frequency spectrometer. The relativistic shift in the cyclotron frequency permits a precise electron energy measurement. Precise beta electron spectroscopy from gaseous radiation sources is a key technique in modern efforts to measure the neutrino mass via the tritium decay end point, and this work demonstrates a fundamentally new approach to precision beta spectroscopy for future neutrino mass experiments. PMID:25955048

  10. Backward wave cyclotron-maser emission in the auroral magnetosphere.

    PubMed

    Speirs, D C; Bingham, R; Cairns, R A; Vorgul, I; Kellett, B J; Phelps, A D R; Ronald, K

    2014-10-10

    In this Letter, we present theory and particle-in-cell simulations describing cyclotron radio emission from Earth's auroral region and similar phenomena in other astrophysical environments. In particular, we find that the radiation, generated by a down-going electron horseshoe distribution is due to a backward-wave cyclotron-maser emission process. The backward wave nature of the radiation contributes to upward refraction of the radiation that is also enhanced by a density inhomogeneity. We also show that the radiation is preferentially amplified along the auroral oval rather than transversely. The results are in agreement with recent Cluster observations. PMID:25375713

  11. RF cavity design for KIRAMS-430 superconducting cyclotron

    NASA Astrophysics Data System (ADS)

    Jung, In Su; Hong, Bong Hwan; Kang, Joonsun; Kim, Hyun Wook; Kim, Chang Hyeuk; Kwon, Key Ho

    2015-03-01

    The Korea Heavy Ion Medical Accelerator (KHIMA) has developed a superconducting cyclotron for the carbon therapy, which is called KIRAMS-430. The cyclotron is designed to accelerate only 12C6+ ions up to the energy of 430 MeV/u. It uses two normal conducting RF cavities. The RF frequency is about 70.76 MHz. The nominal dee voltage is 70 kV at the center and 160 kV at the extraction. The RF cavity was designed with 4 stems by using CST microwave studio (MWS). In this paper, we represent the simulation results and the optimized design of the RF cavity for the KIRAMS-430.

  12. Electron cyclotron heating experiments on the DIII-D tokamak

    SciTech Connect

    Prater, R.; Austin, M.E.; Bernabei, S.

    1998-01-01

    Initial experiments on heating and current drive using second harmonic electron cyclotron heating (ECH) are being performed on the DIII-D tokamak using the new 110 GHz ECH system. Modulation of the ECH power in the frequency range 50 to 300 Hz and detection of the temperature perturbation by ECE diagnostics is used to validate the location of the heating. This technique also determines an upper bound on the width of the deposition profile. Analysis of electron cyclotron current drive indicates that up to 0.17 MA of central current is driven, resulting in a negative loop voltage near the axis.

  13. Backward Wave Cyclotron-Maser Emission in the Auroral Magnetosphere

    NASA Astrophysics Data System (ADS)

    Speirs, D. C.; Bingham, R.; Cairns, R. A.; Vorgul, I.; Kellett, B. J.; Phelps, A. D. R.; Ronald, K.

    2014-10-01

    In this Letter, we present theory and particle-in-cell simulations describing cyclotron radio emission from Earth's auroral region and similar phenomena in other astrophysical environments. In particular, we find that the radiation, generated by a down-going electron horseshoe distribution is due to a backward-wave cyclotron-maser emission process. The backward wave nature of the radiation contributes to upward refraction of the radiation that is also enhanced by a density inhomogeneity. We also show that the radiation is preferentially amplified along the auroral oval rather than transversely. The results are in agreement with recent Cluster observations.

  14. Vacuum measurements of the K500 cyclotron accelerator chamber

    SciTech Connect

    Mallory, M.L.; Miller, P.S.; Kuchar, J.; Hudson, E.D.

    1986-01-01

    To evaluate the effectiveness of the unique internal cryopumping system, the pressure in the K500 superconducting cyclotron was measured as a function of radius for various gas flow rates emanating from the internal PIG source. For the test, a nude ion gauge with vertical dimension less than 2.3 cm was built and mounted on the internal beam probe. The effect of magnetic field on the ion gauge reading was determined and a method of degaussing the cyclotron was devised. Data from the normal shielded ion gauge located approximately 6 m away from the median plane was correlated with the internal vacuum measurements.

  15. Ion cyclotron range of frequency heating of a deuterium-tritium plasma via the second-harmonic tritium cyclotron resonance

    SciTech Connect

    Wilson, J.R.; Bush, C.E.; Darrow, D.; Hosea, J.C.; Jaeger, E.F.; Majeski, R.; Murakami, M.; Phillips, C.K.; Rogers, J.H.; Schilling, G.; Stevens, J.E.; Synakowski, E.; Taylor, G.

    1995-07-31

    Experiments have been performed on the TFTR to study rf wave heating of a D-T plasma by way of the second-harmonic tritium cyclotron resonance. The addition of tritium ions to a deuterium plasma allows for absorption of the rf waves at the tritium cyclotron harmonics and by electron damping of a mode converted ion Bernstein wave. Competing mechanisms include direct electron damping and damping at the fundamental cyclotron resonance of deuterium, {alpha} particles, and {sup 3}He ions. The contribution of each is estimated from a series of plasma discharges where various plasma parameters are varied. The majority of the rf power is found to damp on the tritium ions.

  16. Public census data on CD-ROM at Lawrence Berkeley Laboratory. Revision 1

    SciTech Connect

    Merrill, D.W.

    1992-07-02

    In connection with the Comprehensive Epidemiologic Data Resource (CEDR) and Populations at Risk to Environmental Pollution (PAREP) projects, of the Information and Computing Sciences Division (ICSD) at Lawrence Berkeley Laboratory (LBL), are using public socioeconomic and geographic data files which are available to CEDR and PAREP collaborators via LBL`s computing network. At this time 67 CD-ROM diskettes (approximately 35 gigabytes) are on line via the Unix file server cedrcd.lbl.gov. Most of the files are from the US Bureau of the Census, and most pertain to the 1990 Census of Population and Housing. This paper contains a list of the CD-ROMs available.

  17. Public census data on CD-ROM at Lawrence Berkeley Laboratory

    SciTech Connect

    Merrill, D.W.

    1992-07-02

    In connection with the Comprehensive Epidemiologic Data Resource (CEDR) and Populations at Risk to Environmental Pollution (PAREP) projects, of the Information and Computing Sciences Division (ICSD) at Lawrence Berkeley Laboratory (LBL), are using public socioeconomic and geographic data files which are available to CEDR and PAREP collaborators via LBL's computing network. At this time 67 CD-ROM diskettes (approximately 35 gigabytes) are on line via the Unix file server cedrcd.lbl.gov. Most of the files are from the US Bureau of the Census, and most pertain to the 1990 Census of Population and Housing. This paper contains a list of the CD-ROMs available.

  18. Public census data on CD-ROM at Lawrence Berkeley Laboratory

    SciTech Connect

    Merrill, D.W.

    1992-04-01

    In connection with the comprehensive Epidemiologic Data Resource (CEDR) and Populations at risk to Environmental Pollution (PAREP) projects in the Information and Computing Sciences Division (ICSD) at Lawrence Berkeley Laboratory (LBL), public data files containing socio-economic and geographic data are available to CEDR and PAREP collaborators in the LBL computing network. At this time 60 CD-ROM diskettes (approximately 30 gigabytes) are on line in the Unix file server cedrcd.lbl.gov. Most of the files are from the US Bureau of the Census, and most of those pertain to the 1990 Census of Population and Housing. This paper contains a list of the CD-ROMS available.

  19. Exploratory Research and Development Fund, FY 1990. Report on Lawrence Berkeley Laboratory

    SciTech Connect

    Not Available

    1992-05-01

    The Lawrence Berkeley Laboratory Exploratory R&D Fund FY 1990 report is compiled from annual reports submitted by principal investigators following the close of the fiscal year. This report describes the projects supported and summarizes their accomplishments. It constitutes a part of an Exploratory R&D Fund (ERF) planning and documentation process that includes an annual planning cycle, projection selection, implementation, and review. The research areas covered in this report are: Accelerator and fusion research; applied science; cell and molecular biology; chemical biodynamics; chemical sciences; earth sciences; engineering; information and computing sciences; materials sciences; nuclear science; physics and research medicine and radiation biophysics.

  20. Recent results from the Berkeley 0.3-NA microfield exposure tool

    SciTech Connect

    Naulleau, Patrick; Anderson, Christopher N.; Dean, Kim; Denham, Paul; Goldberg, Kenneth A.; Hoef, Brian; La Fontaine, Bruno; Wallow, Tom

    2007-03-01

    Operating as a SEMATECH resist test center, the Berkeley 0.3-NA EUV microfield exposure tool continues to play a crucial role in the advancement of EUV resists and masks. Here we present recent resist-characterization results from the tool as well as tool-characterization data. In particular we present lithographic-based aberration measurements demonstrating the long-term stability of the tool. We also describe a recent upgrade to the tool which involved redesign of the programmable coherence illuminator to provide improved field uniformity as well as a programmable field size.

  1. Performance of the beam chamber vacuum system of K = 500 cyclotron at Variable Energy Cyclotron Centre Kolkata

    SciTech Connect

    Pal, Gautam DuttaGupta, Anjan; Chakrabarti, Alok

    2014-07-15

    The beam chamber of Variable Energy Cyclotron Centre, Kolkata's K = 500 superconducting cyclotron is pumped by liquid helium cooled cryopanel with liquid nitrogen cooled radiation shield. Performance of the vacuum system was evaluated by cooling the cryopanel assembly with liquid nitrogen and liquid helium. Direct measurement of beam chamber pressure is quite difficult because of space restrictions and the presence of high magnetic field. Pressure gauges were placed away from the beam chamber. The beam chamber pressure was evaluated using a Monte Carlo simulation software for vacuum system and compared with measurements. The details of the vacuum system, measurements, and estimation of pressure of the beam chamber are described in this paper.

  2. Electron cyclotron thruster new modeling results preparation for initial experiments

    NASA Technical Reports Server (NTRS)

    Hooper, E. Bickford

    1993-01-01

    The following topics are discussed: a whistler-based electron cyclotron resonance heating (ECRH) thruster; cross-field coupling in the helicon approximation; wave propagation; wave structure; plasma density; wave absorption; the electron distribution function; isothermal and adiabatic plasma flow; ECRH thruster modeling; a PIC code model; electron temperature; electron energy; and initial experimental tests. The discussion is presented in vugraph form.

  3. Cyclotron Resonance of Electrons Trapped in a Microwave Cavity

    ERIC Educational Resources Information Center

    Elmore, W. C.

    1975-01-01

    Describes an experiment in which the free-electron cyclotron resonance of electrons trapped in a microwave cavity by a Penning trap is observed. The experiment constitutes an attractive alternative to one of the Gardner-Purcell variety. (Author/GS)

  4. Digital control in LLRF system for CYCIAE-100 cyclotron

    NASA Astrophysics Data System (ADS)

    Yin, Zhiguo; Fu, Xiaoliang; Ji, Bin; Zhang, Tianjue; Wang, Chuan

    2016-05-01

    As a driven accelerator, the CYCIAE-100 cyclotron is designed by China Institute of Atomic Energy for the Beijing Radio Ion-beam Facility project. The cyclotron RF system is designed to use two RF power sources of 100 kW to drive two half-wavelength cavities respectively. Two Dee accelerating electrodes are kept separately from each other inside the cyclotron, while their accelerating voltages are maintained in phase by the efforts of LLRF control. An analog-digital hybrid LLRF system has been developed to achieve cavity tuning control, dee voltage amplitude and phase stabilization etc. The analog subsystems designs are focused on RF signal up/down conversion, tuning control, and dee voltage regulation. The digital system provides an RF signal source, aligns the cavity phases and maintains a Finite State Machine. The digital parts combine with the analog functions to provide the LLRF control. A brief system hardware introduction will be given in this paper, followed by the review of several major characteristics of the digital control in the 100 MeV cyclotron LLRF system. The commissioning is also introduced, and most of the optimization during the process was done by changing the digital parts.

  5. Electron-cyclotron-heating experiments in tokamaks and stellarators

    SciTech Connect

    England, A.C.

    1983-01-01

    This paper reviews the application of high-frequency microwave radiation to plasma heating near the electron-cyclotron frequency in tokamaks and stellarators. Successful plasma heating by microwave power has been demonstrated in numerous experiments. Predicted future technological developments and current theoretical understanding suggest that a vigorous program in plasma heating will continue to yield promising results.

  6. Dynamic effects on cyclotron scattering in pulsar accretion columns

    NASA Technical Reports Server (NTRS)

    Brainerd, J. J.; Meszaros, P.

    1991-01-01

    A resonant scattering model for photon reprocessing in a pulsar accretion column is presented. The accretion column is optically thin to Thomson scattering and optically thick to resonant scattering at the cyclotron frequency. Radiation from the neutron star surface propagates freely through the column until the photon energy equals the local cyclotron frequency, at which point the radiation is scattered, much of it back toward the star. The radiation pressure in this regime is insufficient to stop the infall. Some of the scattered radiation heats the stellar surface around the base of the column, which adds a softer component to the spectrum. The partial blocking by the accretion column of X-rays from the surface produces a fan beam emission pattern. X-rays above the surface cyclotron frequency freely escape and are characterized by a pencil beam. Gravitational light bending produces a pencil beam pattern of column-scattered radiation in the antipodal direction, resulting in a strongly angle-dependent cyclotron feature.

  7. Measurement of cyclotron resonance relaxation time in the two-dimensional electron system

    SciTech Connect

    Andreev, I. V. Muravev, V. M.; Kukushkin, I. V.; Belyanin, V. N.

    2014-11-17

    Dependence of cyclotron magneto-plasma mode relaxation time on electron concentration and temperature in the two-dimensional electron system in GaAs/AlGaAs quantum wells has been studied. Comparative analysis of cyclotron and transport relaxation time has been carried out. It was demonstrated that with the temperature increase transport relaxation time tends to cyclotron relaxation time. It was also shown that cyclotron relaxation time, as opposed to transport relaxation time, has a weak electron density dependence. The cyclotron time can exceed transport relaxation time by an order of magnitude in a low-density range.

  8. Environmental health-risk assessment for tritium releases at the National Tritium Labeling Facility at Lawrence Berkeley National Laboratory

    SciTech Connect

    McKone, T.E.; Brand, K.P.; Shan, C.

    1997-04-01

    This risk assessment calculates the probability of experiencing health effects, including cancer incidence due to tritium exposure for three groups of people: (1) LBNL workers near the LBNL facility--Building 75--that uses tritium; (2) other workers at LBNL and nearby neighbors; and (3) people who use the UC Berkeley campus area, and some Berkeley residents. All of these groups share the same probability of health effects from the background radiation from natural sources in the Berkeley area environment, including an increased risk of developing a cancer of 11,000 chances per million. In calculating risk the authors assumed continuous operation in Building 75 for at least a human lifetime. Under this assumption, LBNL workers located near Building 75 have an additional risk of 60 chances out of one million to suffer a cancer; other workers at LBNL and people who live near LBNL have an additional risk of six chances out of one million over a lifetime of exposure; and users of the UC Berkeley campus area and other residents of Berkeley have an additional risk of less than once chance out of one million over a lifetime.

  9. Evaluating a science diversity program at UC Berkeley: more questions than answers.

    PubMed

    Matsui, John; Liu, Roger; Kane, Caroline M

    2003-01-01

    For the past three decades, much attention has been focused on developing diversity programs designed to improve the academic success of underrepresented minorities, primarily in mathematics, science, and engineering. However, ethnic minorities remain underrepresented in science majors and careers. Over the last 10 years, the Biology Scholars Program (BSP), a diversity program at the University of California (UC), Berkeley, has worked to increase the participation and success of students majoring in the biological sciences. A quantitative comparison of students in and out of the program indicates that students in BSP graduate with a degree in biology at significantly higher rates than students not in BSP regardless of race/ethnicity. Furthermore, students who are in BSP have statistically lower high school grade point averages (GPAs) and Scholastic Achievement Test (SAT) scores than students not in BSP. African-American and Hispanic students who join BSP graduate with significantly higher UC Berkeley biology GPAs than non-BSP African-American and Hispanic students, respectively. Majority (Asian and White) students in BSP graduate with statistically similar UC GPAs despite having lower SAT scores than non-BSP majority students. Although BSP students are more successful in completing a biology degree than non-program members, the results raise a series of questions about why the program works and for whom. PMID:12888847

  10. A New Center for Science Education at UC Berkeley's Space Sciences Laboratory

    NASA Astrophysics Data System (ADS)

    Hawkins, I.

    1998-01-01

    The Space Sciences Laboratory at UC Berkeley has established a new Center for Science Education through the Laboratory's Senior Fellow program. The Center has a two-fold mission: (1) science education research through collaborations with UCB Graduate School of Education faculty, and (2) education and outreach projects that bring NASA research to the K-14 and general public communities. The Center is the host of two major education and outreach programs funded by NASA - The Sun-Earth Connection Education Forum (SECEF) and the Science Education Gateway (SEGway) Project. The SECEF - a collaborative between UC Berkeley and NASA's Goddard Space Flight Center - is one of four Forums that have been funded through the Office of Space Science as part of their Education Ecosystem. SEGway is a partnership between science research centers, science museums, and teachers, for the purpose of developing Internet-based, inquiry activities for the K-12 classroom that tap NASA remote sensing data. We will describe the Center for Science Education's history and vision, as well as summarize our core programs.

  11. Catalog of Research Abstracts, 1993: Partnership opportunities at Lawrence Berkeley Laboratory

    SciTech Connect

    Not Available

    1993-09-01

    The 1993 edition of Lawrence Berkeley Laboratory`s Catalog of Research Abstracts is a comprehensive listing of ongoing research projects in LBL`s ten research divisions. Lawrence Berkeley Laboratory (LBL) is a major multi-program national laboratory managed by the University of California for the US Department of Energy (DOE). LBL has more than 3000 employees, including over 1000 scientists and engineers. With an annual budget of approximately $250 million, LBL conducts a wide range of research activities, many that address the long-term needs of American industry and have the potential for a positive impact on US competitiveness. LBL actively seeks to share its expertise with the private sector to increase US competitiveness in world markets. LBL has transferable expertise in conservation and renewable energy, environmental remediation, materials sciences, computing sciences, and biotechnology, which includes fundamental genetic research and nuclear medicine. This catalog gives an excellent overview of LBL`s expertise, and is a good resource for those seeking partnerships with national laboratories. Such partnerships allow private enterprise access to the exceptional scientific and engineering capabilities of the federal laboratory systems. Such arrangements also leverage the research and development resources of the private partner. Most importantly, they are a means of accessing the cutting-edge technologies and innovations being discovered every day in our federal laboratories.

  12. Dynamic regimes of cyclotron instability in the afterglow mode of minimum-B electron cyclotron resonance ion source plasma

    NASA Astrophysics Data System (ADS)

    Mansfeld, D.; Izotov, I.; Skalyga, V.; Tarvainen, O.; Kalvas, T.; Koivisto, H.; Komppula, J.; Kronholm, R.; Laulainen, J.

    2016-04-01

    The paper is concerned with the dynamic regimes of cyclotron instabilities in non-equilibrium plasma of a minimum-B electron cyclotron resonance ion source operated in pulsed mode. The instability appears in decaying ion source plasma shortly (1-10 ms) after switching off the microwave radiation of the klystron, and manifests itself in the form of powerful pulses of electromagnetic emission associated with precipitation of high-energy electrons along the magnetic field lines. Recently it was shown that this plasma instability causes perturbations of the extracted ion current, which limits the performance of the ion source and generates strong bursts of bremsstrahlung emission. In this article we present time-resolved diagnostics of electromagnetic emission bursts related to cyclotron instability in the decaying plasma. The temporal resolution is sufficient to study the fine structure of the dynamic spectra of the electromagnetic emission at different operating regimes of the ion source. It was found that at different values of magnetic field and heating power the dynamic spectra demonstrate common features: Decreasing frequency from burst to burst and an always falling tone during a single burst of instability. The analysis has shown that the instability is driven by the resonant interaction of hot electrons, distributed between the electron cyclotron resonance (ECR) zone and the trap center, with slow extraordinary wave propagation quasi-parallel with respect to the external magnetic field.

  13. Fracture trace map and single-well aquifer test results in a carbonate aquifer in Berkeley County, West Virginia

    USGS Publications Warehouse

    McCoy, Kurt J.; Podwysocki, Melvin H.; Crider, E. Allen; Weary, David J.

    2005-01-01

    These data contain information on the results of single-well aquifer tests, lineament analysis, and a bedrock geologic map compilation for the low-lying carbonate and shale areas of eastern Berkeley County, West Virginia. Efforts have been initiated by management agencies of Berkeley County in cooperation with the U.S. Geological Survey to further the understanding of the spatial distribution of fractures in the carbonate regions and their correlation with aquifer properties. This report presents transmissivity values from about 200 single-well aquifer tests and a map of fracture-traces determined from aerial photos and field investigations. Transmissivity values were compared to geologic factors possibly affecting its magnitude.

  14. Final Environmental Assessment and Finding of No Significant Impact: Construction and Operation of the Molecular Foundry at Ernest Orlando Lawrence Berkeley National Laboratory Berkeley, California

    SciTech Connect

    N /A

    2003-03-07

    Lawrence Berkeley National Laboratory (LBNL) proposes to build a six-story, approximately 86,500 gross square foot (gsf) Molecular Foundry building; and an adjacent 8,000 gsf, partly below-grade Central Utility Plant building (for a combined 94,500 gsf), to be funded and operated by the U.S. Department of Energy's Office of Basic Energy Sciences. The buildings would be located on an approximately 2 1/2-acre site in the southeastern portion of the LBNL facility in the Oakland-Berkeley hills. The site is on mostly undeveloped slopes between Building 72, which is the National Center for Electron Microscopy (NCEM), and Building 66, which is the Surface Science and Catalysis Laboratory (SSCL). The Molecular Foundry building would include laboratories, offices, and conference and seminar rooms; the Central Utility Plant would also serve as the foundation for 16 surface parking spaces. A new plaza and pedestrian bridges would connect or provide ready access between the proposed Molecular Foundry building and adjacent scientific buildings. The Proposed Action would extend Lee Road approximately 350 feet, and widen a portion of the road to accommodate two-way traffic. The Molecular Foundry would be staffed and/or used by an estimated 137 persons, of whom an estimated 59 would be staff persons, 36 would be students, and 42 would be visitors (i.e., visiting scientists) to the Center. The Proposed Action would require removal of an existing paved 18-space parking lot and retaining walls, as well as excavation into an undeveloped hillside. Approximately two-dozen mature trees would be removed along with approximately one-dozen saplings. The Proposed Action would replant or replace trees, generally in-kind and in or around the site. LBNL anticipates it would reuse all soil excavated for the Molecular Foundry to construct the new Lee Road extension and widen the existing roadway. This Proposed Action would be a resource for the Department of Energy's participation in the National

  15. Stability of the Zagreb realization of the Carnegie-Mellon-Berkeley coupled-channels unitary model

    SciTech Connect

    Osmanovic, H.; Hadzimehmedovic, M.; Stahov, J.; Ceci, S.; Svarc, A.

    2011-09-15

    In Hadzimehmedovicet al.[Phys. Rev. C 84, 035204 (2011)] we have used the Zagreb realization of Carnegie-Melon-Berkeley coupled-channel, unitary model as a tool for extracting pole positions from the world collection of partial-wave data, with the aim of eliminating model dependence in pole-search procedures. In order that the method is sensible, we in this paper discuss the stability of the method with respect to the strong variation of different model ingredients. We show that the Zagreb CMB procedure is very stable with strong variation of the model assumptions and that it can reliably predict the pole positions of the fitted partial-wave amplitudes.

  16. Lawrence Berkeley National Laboratory 1995 site environmental report: Volume 2, Data appendix

    SciTech Connect

    1996-07-01

    Ernest Orlando Lawrence Berkeley National Laboratory presents Volume II, Data Appendix as a reference document to supplement the 1995 Site Environmental Report. Volume II contains the raw environmental monitoring and sampling data used to generate many of the summary results included in the main report. Supplemental data is provided for sitewide activities involving the media of stack and ambient air quality, rainwater, surface water, stormwater, wastewater, and soil and sediment. Volume II also contains supplemental data on the special preoperational monitoring study for the new Hazardous Waste Handling Facility. The Table of Contents provides a cross-reference to the data tables of the main report and this appendix. Data are given in System International (SI) units.

  17. Fifty Years of Progress, 1937-1987 [Lawrence Berkeley Laboratory (LBL, LBNL)

    DOE R&D Accomplishments Database

    Budinger, T. F. (ed.)

    1987-01-01

    This booklet was prepared for the 50th anniversary of medical and biological research at the Donner Laboratory and the Lawrence Berkeley Laboratory of the University of California. The intent is to present historical facts and to highlight important facets of fifty years of accomplishments in medical and biological sciences. A list of selected scientific publications from 1937 to 1960 is included to demonstrate the character and lasting importance of early pioneering work. The organizational concept is to show the research themes starting with the history, then discoveries of medically important radionuclides, then the use of accelerated charged particles in therapy, next human physiology studies then sequentially studies of biology from tissues to macromolecules; and finally studies of the genetic code.

  18. Studies, Transport and Treatment Concept for Boilers from Berkeley NPP, England - 13599

    SciTech Connect

    Wirendal, Bo; Saul, David; Robinson, Joe; Davidson, Gavin

    2013-07-01

    In November 2011 Studsvik was awarded a contract to transport five decommissioned boilers from the Berkeley Nuclear Licensed Site in the UK to the Studsvik Nuclear Site in Sweden for metal treatment and recycling. A key objective of the project was to remove the boilers from the site by 31 March 2012 and this was successfully achieved with all boilers off site by 22 March and delivered to Studsvik on 6 April. Four boilers have been processed and the fifth is planned for completion by end of December 2012.The project had many challenges including a very tight timescale and has been successfully delivered to cost and ahead of the baseline programme. This paper describes the project and the experience gained from treatment of the first four boilers. It is the first UK project to send large components overseas for recycling and provides new insight into the processing of Magnox gas-circuit components. (authors)

  19. Simulation of the GRETINA Scanning Table at Lawrence Berkeley National Laboratory

    NASA Astrophysics Data System (ADS)

    Haldeman, Ethan

    2015-10-01

    We developed a GEANT4 simulation of the GRETINA scanning table at Lawrence Berkeley National Laboratory. The scanning table is used to study signal decomposition and to map the segmentation of GRETINA crystals. The data can also be analyzed to better understand characteristics of GRETINA like its geometry, resolution, and efficiency. The simulation is used both to plan measurements and interpret results. Complex components of the scanning table were implemented in the simulation using STL files created from CAD drawings which were imported to the code using the open source package CADMesh. Measurements of a GRETINA module will be presented and compared with simulations. This work was supported by the National Science Foundation under Grant Nos. PHY-1303480 and PHY-1102511 and by the US Department of Energy under Grant No. DE-AC02-05CH11231.

  20. Base-flow yields of watersheds in the Berkeley County area, West Virginia

    USGS Publications Warehouse

    Evaldi, Ronald D.; Paybins, Katherine S.

    2006-01-01

    Base-flow yields at approximately 50 percent of the annual mean ground-water recharge rate were estimated for watersheds in the Berkeley County area, W.Va. These base-flow yields were determined from two sets of discharge measurements made July 25-28, 2005, and May 4, 2006. Two sections of channel along Opequon Creek had net flow losses that are expressed as negative base-flow watershed yields; these and other base-flow watershed yields in the eastern half of the study area ranged from -940 to 2,280 gallons per day per acre ((gal/d)/acre) and averaged 395 (gal/d)/acre. The base-flow yields for watersheds in the western half of the study area ranged from 275 to 482 (gal/d)/acre and averaged 376 (gal/d)/acre.

  1. FIFI: The MPE Garching/UC Berkeley Far-Infrared Imaging Fabry-Perot Interferometer

    NASA Technical Reports Server (NTRS)

    Geis, Norbert; Genzel, Reinhard; Haggerty, M.; Herrmann, F.; Jackson, J.; Madden, Suzanne C.; Nikola, T.; Poglitsch, Albrecht; Rumitz, M.; Stacey, G. J.

    1995-01-01

    We describe the performance characteristics of the MPE Garching/UC Berkeley Far-Infrared Imaging Fabry-Perot Interferometer (FIFI) for the Kuiper Airborne Observatory (KAO). The spectrometer features two or three cryogenic tunable Fabry-Perot filters in series giving spectral resolution R of up to 10(exp 5) in the range of 40 microns less than lambda less than 200 microns, and an imaging 5x5 array of photoconductive detectors with variable focal plane plate scale. The instrument works at background limited sensitivity of up to 2 x 10(exp -19) W cm(exp -2) Hz(exp -1/2) per pixel per resolution element at R = 10(exp 5) on the KAO.

  2. Relation of bacteria in limestone aquifers to septic systems in Berkeley County, West Virginia

    USGS Publications Warehouse

    Mathes, M.V.

    2000-01-01

    Water samples collected from 50 wells in Berkeley County, West Virginia, during June 2000 were analyzed for indicator bacteria. Of the 50 wells sampled, 62 percent (31 wells) contained total coliform bacteria, 32 percent (16 wells) contained Escherichia coli, and 30 percent (15 wells) contained fecal coliform bacteria. Although bacteria were present in many wells regardless of the number of septic systems in a 5-acre circular area around each well, no apparent correlation was detected between septic-system density and concentrations of bacteria colonies. There was also little difference in the frequency of total coliform bacteria detection between shallow and deep wells; however, the highest concentrations of E. coli and fecal coliform bacteria were found in the shallowest wells. At least one of the three bacteria types was found in samples of untreated water in 32 of the 50 wells. At 21 of the 32 wells with bacteria present, there was no treatment of the ground water to remove bacteria.

  3. VizieR Online Data Catalog: Berkeley supernova Ia program. II. (Silverman+, 2012)

    NASA Astrophysics Data System (ADS)

    Silverman, J. M.; Kong, J. J.; Filippenko, A. V.

    2013-08-01

    In this second paper in a series, we present measurements of spectral features of 432 low-redshift (z<0.1) optical spectra of 261 Type Ia supernovae (SNe Ia) within 20d of maximum brightness. The data were obtained from 1989 to the end of 2008 as part of the Berkeley Supernova Ia Program (BSNIP) and are presented in BSNIP I by Silverman et al. (J/MNRAS/425/1789). We describe in detail our method of automated, robust spectral feature definition and measurement which expands upon similar previous studies. Using this procedure, we attempt to measure expansion velocities, pseudo-equivalent widths (pEWs), spectral feature depths and fluxes at the centre and endpoints of each of nine major spectral feature complexes. (10 data files).

  4. Hazardous Waste Certification Plan: Hazardous Waste Handling Facility, Lawrence Berkeley Laboratory

    SciTech Connect

    Not Available

    1992-02-01

    The purpose of this plan is to describe the organization and methodology for the certification of hazardous waste (HW) handled in the Lawrence Berkeley Laboratory (LBL) Hazardous Waste Handling Facility (HWHF). The plan also incorporates the applicable elements of waste reduction, which include both up-front minimization and end- product treatment to reduce the volume and toxicity of the waste; segregation of the waste as it applies to certification; and executive summary of the Quality Assurance Program Plan (QAPP) for the HWHF and a list of the current and planned implementing procedures used in waste certification. The plan provides guidance from the HWHF to waste generators, waste handlers, and the Systems Group Manager to enable them to conduct their activities and carry out their responsibilities in a manner that complies with several requirements of the Federal Resource Conservation and Resource Recovery Act (RCRA), the Federal Department of Transportation (DOT), and the State of California, Code of Regulations (CCR), Title 22.

  5. VLA high resolution observations of weak Leiden-Berkeley Deep-Survey (LBDS) sources

    NASA Astrophysics Data System (ADS)

    Oort, M. J. A.; Katgert, P.; Steeman, F. W. M.; Windhorst, R. A.

    1987-06-01

    The majority of the 1-arcsec resolution snapshot maps of 133 radio sources presented from the Leiden-Berkeley Deep Survey (LBDS) indicate that the sources have flux densities in the 1-100 mJy range at 1.4 GHz, with a median flux density of 5 mJy. A combination of all radio-morphological data available for the LBDS, the median angular size of a complete radio sample is found to decrease with decreasing flux density to a value as low as about 2 arcsec between 1 and 10 mJy. Definite indications are found for a decrease of intrinsic size with increasing redshift, with a relation that results in a size decrease of factor 4 with respect to the local value at the same radio power.

  6. Public census data on CD-ROM at Lawrence Berkeley Laboratory. Revision 4

    SciTech Connect

    Merrill, D.W.

    1993-03-12

    The Comprehensive Epidemiologic Data Resource (CEDR) and Populations at Risk to Environmental Pollution (PAREP) projects, of the Information and Computing sciences Division (ICSD) at Lawrence Berkeley Laboratory (LBL), are using public socioeconomic and geographic data files which are available to CEDR and PAREP collaborators via LBL`s computing network. At this time 89 CD-ROM diskettes (approximately 45 gigabytes) are on line via the Unix file server cedrcd.lbl.gov. Most of the files are from the US Bureau of the Census, and many of these pertain to the 1990 Census of Population and Housing. All the CD-ROM diskettes contain documentation in the form of ASCII text files. In addition, printed documentation for most files is available for inspection at University of California Data and Technical Assistance (UC DATA), tel. (510) 642-6571, or the UC Documents Library, tel. (510) 642-2569, both located on the UC Berkeley Campus. Many of the CD-ROM diskettes distributed by the Census Bureau contain software for PC compatible computers, for easily accessing the data. Shared access to the data is maintained through a collaboration among the CEDR and PAREP projects at LBL, and UC DATA, and the UC Documents Library. LBL is grateful to UC DATA and the UC Documents Library for the use of their CD-ROM diskettes. Shared access to LBL facilities may be restricted in the future if costs become prohibitive. Via the Sun Network File System (NFS), these data can be exported to Internet computers for direct access by the user`s application program(s). Due to the size of the files, this access method is preferred over File Transfer Protocol (FTP) access.

  7. Public census data on CD-ROM at Lawrence Berkeley Laboratory

    SciTech Connect

    Merrill, D.W.

    1993-01-16

    The Comprehensive Epidemiologic Data Resource (CEDR) and Populations at Risk to Environmental Pollution (PAREP) projects, of the Information and Computing Sciences Division (ICSD) at Lawrence Berkeley Laboratory (LBL), are using public socioeconomic and geographic data files which are available to CEDR and PAREP collaborators via LBL's computing network. At this time 72 CD-ROM diskettes (approximately 37 gigabytes) are on line via the Unix file server cedrcd.lbl.gov''. Most of the files are from the US Bureau of the Census, and many of these pertain to the 1990 Census of Population and Housing. All the CD-ROM diskettes contain documentation in the form of ASCII text files. In addition, printed documentation for most files is available for inspection at University of California Data and Technical Assistance (UC DATA), tel. (510) 642-6571, or the UC Documents Library, tel. (510) 642-2569, both located on the UC Berkeley Campus. Many of the CD-ROM diskettes distributed by the Census Bureau contain software for PC compatible computers, for easily accessing the data. Shared access to the data is maintained through a collaboration among the CEDR and PAREP projects at LBL, and UC DATA, and the UC Documents Library. LBL is grateful to UC DATA and the UC Documents Library for the use of their CD-ROM diskettes. Shared access to LBL facilities may be restricted in the future if costs become prohibitive. Via the Sun Network File System (NFS), these data can be exported to Internet computers for direct access by the user's application program(s). Due to the size of the files, this access method is preferred over File Transfer Protocol (FTP) access. Please contact Deane Merrill (dwmerrill lbl.gov) if you wish to make use of the data.

  8. Public census data on CD-ROM at Lawrence Berkeley Laboratory. Revision 3

    SciTech Connect

    Merrill, D.W.

    1993-01-16

    The Comprehensive Epidemiologic Data Resource (CEDR) and Populations at Risk to Environmental Pollution (PAREP) projects, of the Information and Computing Sciences Division (ICSD) at Lawrence Berkeley Laboratory (LBL), are using public socioeconomic and geographic data files which are available to CEDR and PAREP collaborators via LBL`s computing network. At this time 72 CD-ROM diskettes (approximately 37 gigabytes) are on line via the Unix file server ``cedrcd.lbl.gov``. Most of the files are from the US Bureau of the Census, and many of these pertain to the 1990 Census of Population and Housing. All the CD-ROM diskettes contain documentation in the form of ASCII text files. In addition, printed documentation for most files is available for inspection at University of California Data and Technical Assistance (UC DATA), tel. (510) 642-6571, or the UC Documents Library, tel. (510) 642-2569, both located on the UC Berkeley Campus. Many of the CD-ROM diskettes distributed by the Census Bureau contain software for PC compatible computers, for easily accessing the data. Shared access to the data is maintained through a collaboration among the CEDR and PAREP projects at LBL, and UC DATA, and the UC Documents Library. LBL is grateful to UC DATA and the UC Documents Library for the use of their CD-ROM diskettes. Shared access to LBL facilities may be restricted in the future if costs become prohibitive. Via the Sun Network File System (NFS), these data can be exported to Internet computers for direct access by the user`s application program(s). Due to the size of the files, this access method is preferred over File Transfer Protocol (FTP) access. Please contact Deane Merrill (dwmerrill@lbl.gov) if you wish to make use of the data.

  9. Biomedical applications of cyclotrons and review of commercially available models.

    PubMed

    Birattari, C; Bonardi, M; Ferrari, A; Milanesi, L; Silari, M

    1987-01-01

    The growing use of cyclotrons in biomedicine, both for clinical and research purposes and in particular for the production of short-lived radionuclides which are extremely useful in nuclear medicine diagnosis, has reached a stage in which commercial companies are able to offer several models with different performances, in order to satisfy the demand of different users. Many of these commercially produced accelerators are installed all over the world and some of them have been operating for several years, demonstrating that this category of machine has reached a high degree of reliability. A brief description of the operating principle of the cyclotron is presented, together with an illustration of its possible applications in the medical field. A list of the models presently available on the market is given and the installation problems and the criteria to be followed in the choice of a model are discussed. Finally, likely future developments in the field are briefly discussed. PMID:2824778

  10. Ion Behavior in an Electrically Compensated Ion Cyclotron Resonance Trap

    PubMed Central

    Brustkern, Adam M.; Rempel, Don L.; Gross, Michael L.

    2010-01-01

    We recently described a new electrically compensated trap in FT ion cyclotron resonance mass spectrometry and developed a means of tuning traps of this general design. Here, we describe a continuation of that research by comparing the ion transient lifetimes and the resulting mass resolving powers and signal-to-noise (S/N) ratios that are achievable in the compensated vs. uncompensated modes of this trap. Transient lifetimes are ten times longer under the same conditions of pressure, providing improved mass resolving power and S/N ratios. The mass resolving power as a function of m/z is linear (log-log plot) and nearly equal to the theoretical maximum. Importantly, the ion cyclotron frequency as a function of ion number decreases linearly in accord with theory, unlike its behavior in the uncompensated mode. This linearity should lead to better control in mass calibration and increased mass accuracy than achievable in the uncompensated mode. PMID:21499521

  11. Neutron spectra due (13)N production in a PET cyclotron.

    PubMed

    Benavente, J A; Vega-Carrillo, H R; Lacerda, M A S; Fonseca, T C F; Faria, F P; da Silva, T A

    2015-05-01

    Monte Carlo and experimental methods have been used to characterize the neutron radiation field around PET (Positron Emission Tomography) cyclotrons. In this work, the Monte Carlo code MCNPX was used to estimate the neutron spectra, the neutron fluence rates and the ambient dose equivalent (H*(10)) in seven locations around a PET cyclotron during (13)N production. In order to validate these calculations, H*(10) was measured in three sites and were compared with the calculated doses. All the spectra have two peaks, one above 0.1MeV due to the evaporation neutrons and another in the thermal region due to the room-return effects. Despite the relatively large difference between the measured and calculated H*(10) for one point, the agreement was considered good, compared with that obtained for (18)F production in a previous work. PMID:25699664

  12. Radiation protection aspects of the operation in a cyclotron facility

    NASA Astrophysics Data System (ADS)

    Silva, P. P. N.; Carneiro, J. C. G. G.

    2014-02-01

    The activated accelerator cyclotron components and the radioisotope production may impact on the personnel radiation exposure of the workers during the routine maintenance and emergency repair procedures and any modification of the equipment. Since the adherence of the principle of ALARA (as low as reasonable achievable) constitutes a major objective of the cyclotron management, it has become imperative to investigate the radiation levels at the workplace and the probable health effects to the worker caused by radiation exposure. The data analysis in this study was based on the individual monitoring records during the period from 2007 to 2011. Monitoring of the workplace was also performed using gamma and neutron detectors to determine the dose rate in various predetermined spots. The results of occupational radiation exposures were analysed and compared with the values established in national standards and international recommendations. Important guidelines have been developed to reduce the individual dose.

  13. PHYSICS OF ELECTRON CYCLOTRON CURRENT DRIVE ON DIII-D

    SciTech Connect

    PETTY,CC; PRATER,R; LUCE,TC; ELLIS,RA; HARVEY,RW; KINSEY,JE; LAO,LL; LOHR,J; MAKOWSKI,MA

    2002-11-01

    OAK A271 PHYSICS OF ELECTRON CYCLOTRON CURRENT DRIVE ON DIII-D. Recent experiments on the DIII-D tokamak have focused on determining the effect of trapped particles on the electron cyclotron current drive (ECCD) efficiency. The measured ECCD efficiency increases as the deposition location is moved towards the inboard midplane or towards smaller minor radius for both co and counter injection. The measured ECCD efficiency also increases with increasing electron density and/or temperature. The experimental ECCD is compared to both the linear theory (Toray-GA) as well as a quasilinear Fokker-Planck model (CQL3D). The experimental ECCD is found to be in better agreement with the more complete Fokker-Planck calculation, especially for cases of high rf power density and/or loop voltage.

  14. Radiation effects testing at the 88-Inch Cyclotron

    NASA Astrophysics Data System (ADS)

    Phair, Larry

    2015-10-01

    In addition to basic research, the 88-Inch Cyclotron provides a crucial service to organizations involved in the U.S. space program. The space application testing includes heavy-ion beams for single event upset (SEU) tests on integrated circuits. A ``Cocktail'' beam (where multiple ions of the same mass/charge ratio are injected into the cyclotron) is used to mimic cosmic ray damage of integrated circuits. Plots of the failure cross section versus amount of energy deposited (LET = linear energy transfer) for different beams are used to predict how the circuit components will perform in a radiation environment such as space. We will review the analysis of such data and their trends.

  15. Evidence for proton cyclotron waves near Comet Giacobini-Zinner

    NASA Technical Reports Server (NTRS)

    Tan, L. C.; Mason, G. M.; Tsurutani, B. T.

    1993-01-01

    We have computed frequency spectra of power density and polarization parameters of magnetohydrodynamic waves from observations on board the ICE spacecraft as it flew past Comet Giacobini-Zinner on September 11, 1985. Since the spectral parameters are frequency dependent, we find that the analysis is best carried out in a 'wave' reference frame where one of the major axes is along the wave normal direction for each frequency component. The power density along the wave normal direction shows a systematic peak structure which we identify as belonging to cyclotron wave harmonics of pickup ions near the comet. The fundamental harmonics of the cyclotron waves are also consistent with the gyrofrequencies calculated from the magnetic field data.

  16. Loss-cone-driven ion cyclotron waves in the magnetosphere

    NASA Technical Reports Server (NTRS)

    Denton, Richard E.; Hudson, Mary K.; Roth, Ilan

    1992-01-01

    The study examines the theoretical properties of linear ion cyclotron waves propagating in the magnetosphere at arbitrary angles to the background magnetic field. It is found that in some cases the linear wave growth of modes with oblique propagation can dominate that of the parallel propagating electromagnetic ion cyclotron (EMIC) wave. The growth rate of the loss-cone-driven mode depends strongly on the depth of the loss cone. A simple analytical theory which explains the scaling of the growth rate of the oblique mode with respect to various parameters is presented. The loss-cone-driven mode is an electromagnetic mode which is preferentially nearly linearly polarized. The wave field which results from the oblique mode in its perferentially nearly linearly polarized form are nearly perpendicular to B0 and are such that they may be difficult to distinguish from those of a linearly polarized parallel propgating EMIC wave.

  17. Ion cyclotron heating experiments in magnetosphere plasma device RT-1

    SciTech Connect

    Nishiura, M. Yoshida, Z.; Yano, Y.; Kawazura, Y.; Saitoh, H.; Yamasaki, M.; Mushiake, T.; Kashyap, A.; Takahashi, N.; Nakatsuka, M.; Fukuyama, A.

    2015-12-10

    The ion cyclotron range of frequencies (ICRF) heating with 3 MHz and ∼10 kW is being prepared in RT-1. The operation regime for electron cyclotron resonance (ECR) heating is surveyed as the target plasmas. ECRH with 8.2 GHz and ∼50 kW produces the plasmas with high energy electrons in the range of a few ten keV, but the ions still remain cold at a few ten eV. Ion heating is expected to access high ion beta state and to change the aspect of plasma confinement theoretically. The ICRF heating is applied to the target plasma as an auxiliary heating. The preliminary result of ICRF heating is reported.

  18. Nonlinear particle simulation of ion cyclotron waves in toroidal geometry

    SciTech Connect

    Kuley, A. Lin, Z.; Bao, J.; Wei, X. S.; Xiao, Y.

    2015-12-10

    Global particle simulation model has been developed in this work to provide a first-principles tool for studying the nonlinear interactions of radio frequency (RF) waves with plasmas in tokamak. In this model, ions are considered as fully kinetic particles using the Vlasov equation and electrons are treated as guiding centers using the drift kinetic equation with realistic electron-to-ion mass ratio. Boris push scheme for the ion motion has been developed in the toroidal geometry using magnetic coordinates and successfully verified for the ion cyclotron and ion Bernstein waves in global gyrokinetic toroidal code (GTC). The nonlinear simulation capability is applied to study the parametric decay instability of a pump wave into an ion Bernstein wave side band and a low frequency ion cyclotron quasi mode.

  19. LH wave absorption by mode conversion near ion cyclotron harmonics

    SciTech Connect

    Ko, K.; Bers, A.; Fuchs, V.

    1981-02-01

    Numerical studies of the dispersion relation near the lower-hybrid frequency in an inhomogeneous plasma (..delta.. n, ..delta.. T, ..delta.. B) show that portions of an incident lower-hybrid wave spectrum undergo successive but partial mode conversions to warm-plasma waves in the presence of ion cyclotron harmonics. Wave absorption beyond the first mode conversion occurs near an ion cyclotron harmonic where ion Landau damping is enhanced. A second-order dispersion relation numerically in good agreement with the full dispersion relation in the mode conversion region is derived using the condition par. delta D/par. delta k = 0. The mode conversion efficiency at each confluence is evaluated by solving the corresponding differential equation.

  20. Heating by waves in the ion cyclotron frequency range

    SciTech Connect

    Koch, R.

    1996-03-01

    The main aspects of heating with the fast wave in the ion cyclotron range of frequencies (ICRF) are reviewed. First, the ion cyclotron resonance mechanism, fundamental and harmonics, is examined. Then the properties of fast wave dispersion are reviewed, and the principles of minority and higher cylcotron harmonic heating are discussed. An elementary coupling model is worked out in order to outline the computation of the electrical properties of ICRF antennas. Using the simple model, the antenna radiation pattern inside the plasma is computed and the effect of phasing on the k spectrum and on the antenna radiation properties is illustrated. The quasi linear-Fokker-Planck computation of the deformation of distribution functions due to Radio-Frequency (RF) and tail formation are briefly discussed. 11 refs., 5 figs.

  1. Sawtooth control in ITER using ion cyclotron resonance heating

    SciTech Connect

    Chapman, I. T.; Graves, J P; Johnson, T.; Asunta, O.; Bonoli, P.; Choi, M.; Jaeger, E. F.; Jucker, M.; Sauter, O.

    2011-01-01

    Numerical modeling of the effects of ion cyclotron resonance heating (ICRH) on the stability of the internal kink mode suggests that ICRH should be considered as an essential sawtooth control tool in ITER. Sawtooth control using ICRH is achieved by directly affecting the energy of the internal kink mode rather than through modification of the magnetic shear by driving localized currents. Consequently, ICRH can be seen as complementary to the planned electron cyclotron current drive actuator, and indeed will improve the efficacy of current drive schemes. Simulations of the ICRH distribution using independent RF codes give confidence in numerical predictions that the stabilizing influence of the fusion-born alphas can be negated by appropriately tailored minority (3)He ICRH heating in ITER. Finally, the effectiveness of all sawtooth actuators is shown to increase as the q = 1 surface moves towards the manetic axis, whilst the passive stabilization arising from the alpha and NBI particles decreases.

  2. Examination of the plasma located in PSI Ring Cyclotron

    NASA Astrophysics Data System (ADS)

    Pogue, N. J.; Adelmann, A.; Schneider, M.; Stingelin, L.

    2016-06-01

    A plasma has been observed inside the vacuum chamber of the PSI Ring Cyclotron. This ionized gas cloud may be a substantial contributor to several interior components having reduced lifetimes. The plasma's generation has been directly linked to the voltage that is applied to the Flat Top cavity through visual confirmation using CCD cameras. A spectrometer was used to correlate the plasma's intensity and ignition to the Flat Top cavity voltage as well as to determine the composition of the plasma. This paper reports on the analysis of the plasma using spectroscopy. The spectrometer data was analyzed to determine the composition of the plasma and that the plasma intensity (luminosity) directly corresponds to the Flat Top voltage. The results show that the plasma is comprised of elements consistent with the cyclotrons vacuum interior.

  3. RF Heating in Electron Cyclotron Resonance Ion Sources

    NASA Astrophysics Data System (ADS)

    Mascali, D.; Gammino, S.; Celona, L.; Ciavola, G.

    2011-12-01

    ECRIS—Electron Cyclotron Resonance Ion Sources are able to feed accelerators with intense currents of highly charged ions. In ECRIS a high density—high temperature plasma is generated by means of the Electron Cyclotron Resonance Heating inside a B-min, MHD stable trap. The state of the art about the principal heating mechanisms will be given. The paper will specially discuss the most critical and still open issues concerning the influence of the magnetic field and of the RF frequency on the plasma heating, as well as the impact of possible non-linear pumping wave—to—plasma interactions. The contribution of INFN-LNS will be specifically underlined. A short review on the future perspectives for the design of new generation ion sources will be given in conclusion.

  4. Electrostatic ion-cyclotron waves in magnetospheric plasmas Nonlocal aspects

    NASA Technical Reports Server (NTRS)

    Ganguli, G.; Bakshi, P.; Palmadesso, P.

    1984-01-01

    The importance of the effect of the magnetic shear and the finite size of current channel on the electrostatic ion-cyclotron instability for the space plasmas is illustrated. A non-local treatment is used. When the channel width Lc, is larger than the shear length Ls, there is a large reduction in the growth rate along with a noteworthy reduction of the band of the unstable perpendicular wavelengths. For Lc less than or = Ls/10 the growth rate is not much altered from its local value, however for Lc/pi i less than or = 10 to the second power the growth rate starts falling below the local value and vanishes for Lc pi i. The non-local effects lead to enhanced coherence in the ion cyclotron waves. Previously announced in STAR as N84-14917

  5. Cyclotron resonance in topological insulators: non-relativistic effects

    NASA Astrophysics Data System (ADS)

    Tabert, C. J.; Carbotte, J. P.

    2015-09-01

    The low-energy Hamiltonian used to describe the dynamics of the helical Dirac fermions on the surface of a topological insulator contains a subdominant non-relativistic (Schrödinger) contribution. This term can have an important effect on some properties while having no effect on others. The Hall plateaus retain the same relativistic quantization as the pure Dirac case. The height of the universal interband background conductivity is unaltered, but its onset is changed. However, the non-relativistic term leads directly to particle-hole asymmetry. It also splits the interband magneto-optical lines into doublets. Here, we find that, while the shape of the semiclassical cyclotron resonance line is unaltered, the cyclotron frequency and its optical spectral weight are changed. There are significant differences in both of these quantities for a fixed value of chemical potential or fixed doping away from charge neutrality depending on whether the Fermi energy lies in the valence or conduction band.

  6. Evidence for proton cyclotron waves near Comet Giacobini-Zinner

    NASA Astrophysics Data System (ADS)

    Tan, L. C.; Mason, G. M.; Tsurutani, B. T.

    1993-02-01

    We have computed frequency spectra of power density and polarization parameters of magnetohydrodynamic waves from observations on board the ICE spacecraft as it flew past Comet Giacobini-Zinner on September 11, 1985. Since the spectral parameters are frequency dependent, we find that the analysis is best carried out in a 'wave' reference frame where one of the major axes is along the wave normal direction for each frequency component. The power density along the wave normal direction shows a systematic peak structure which we identify as belonging to cyclotron wave harmonics of pickup ions near the comet. The fundamental harmonics of the cyclotron waves are also consistent with the gyrofrequencies calculated from the magnetic field data.

  7. Radial-longitudinal coupling in proposed RCNP injector cyclotron

    SciTech Connect

    Yamuzaki, T.; Hosono, K.; Kadota, Y.; Miura, I.; Saito, T.; Tei, T.

    1985-10-01

    For an injector cyclotron to a ring cyclotron proposed at RCNP, the second, third and fourth harmonic modes are used for the light ion acceleration. To accelerate ions in these harmonic modes without phase space deformation, it is necessary to investigate the effect of radial-longitudinal coupling. For single, two and three dee configurations, the beam behavior in radial phase space was studied numerically for each harmonic mode and dee angle. In the case of the second and third harmonic accelerations of protons with two dees, dee angles between 60 and 75 degrees are acceptable. The results are compared with 180-degree single dee and 40-degree three dees for the third harmonic mode.

  8. Remote target removal for the Oak Ridge 86-inch Cyclotron

    SciTech Connect

    Walls, A.A.

    1982-01-01

    A remotely operated target remover has been plaed in operation at the 86-Inch Cyclotron located in Oak Ridge. The system provides for the remote removal of a target from inside the cyclotron, loading it into a cask, and the removal of the cask from the 1.5 m (5-ft) shielding walls. The remote system consists of multiple electrical and pneumatically operated equipment which is designed for controlled step-by-step operation, operated with an electrical control panel, and monitored by a television system. The target remover has reduced the radiation exposures to operating personnel at the facility and has increased the effective operating time. The system is fast, requires a minimum of skill to operate, and has demonstrated both reliability and durability.

  9. Aharonov-Bohm effect in cyclotron and synchrotron radiations

    NASA Astrophysics Data System (ADS)

    Bagrov, V. G.; Gitman, D. M.; Levin, A.; Tlyachev, V. B.

    2001-07-01

    We study the impact of Aharonov-Bohm solenoid on the radiation of a charged particle moving in a constant uniform magnetic field. With this aim in view, exact solutions of Klein-Gordon and Dirac equations are found in the magnetic-solenoid field. Using such solutions, we calculate exactly all the characteristics of one-photon spontaneous radiation both for spinless and spinning particle. Considering non-relativistic and relativistic approximations, we analyze cyclotron and synchrotron radiations in detail. Radiation peculiarities caused by the presence of the solenoid may be considered as a manifestation of Aharonov-Bohm effect in the radiation. In particular, it is shown that new spectral lines appear in the radiation spectrum. Due to angular distribution peculiarities of the radiation intensity, these lines can in principle be isolated from basic cyclotron and synchrotron radiation spectra.

  10. PHYSICS OF ELCTRON CYCLOTRON CURRENT DRIVE ON DIII-D

    SciTech Connect

    PETTY,CC; PRATER,R; LUCE,TC; ELLIS,RA; HARVEY,RW; KINSEY,JE; LAO,LL; LOHR,J; MAKOWSKI,MA

    2002-09-01

    OAK A271 PHYSICS OF ELCTRON CYCLOTRON CURRENT DRIVE ON DIII-D. Recent experiments on the DIII-D tokamak have focused on determining the effect of trapped particles on the electron cyclotron current drive (ECCD) efficiency. The measured ECCD efficiency increases as the deposition location is moved towards the inboard midplane or towards smaller minor radius for both co and counter injection. The measured ECCD efficiency also increases with increasing electron density and/or temperature. The experimental ECCD is compared to both the linear theory (Toray-GA) as well as a quasilinear Fokker-Planck model (CQL3D). The experimental ECCD is found to be in better agreement with the more complete Fokker-Planck calculation, especially for cases of high rf power density and/or loop voltage. The narrow width of the measured ECCD profile is consistent with only low levels of radial transport for the current carrying electrons.

  11. RF physics of ICWC discharge at high cyclotron harmonics

    NASA Astrophysics Data System (ADS)

    Lyssoivan, A.; van Eester, D.; Wauters, T.; Bobkov, V.; Vervier, M.; Douai, D.; Kogut, D.; Kreter, A.; Moiseenko, V.; Möller, S.; Noterdaeme, J.-M.; Philipps, V.; Rohde, V.; Schneider, P.; Sergienko, G.; van Schoor, M.; Textor Team, ASDEX Upgrade Team

    2014-02-01

    Recent experiments on Ion Cyclotron Wall Conditioning (ICWC) performed in tokamaks TEXTOR and ASDEX Upgrade with standard ICRF antennas operated at fixed frequencies but variable toroidal magnetic field demonstrated rather contrasting parameters of ICWC discharge in scenarios with on-axis fundamental ion cyclotron resonance (ICR) for protons,ω=ωH+, and with its high cyclotron harmonics (HCH), ω=10ωcH+ṡ HCH scenario: very high antenna coupling to low density RF plasmas (Ppl≈0.9PRF-G) and low energy Maxwellian distribution of CX hydrogen atoms with temperature TH≈350 eV. Fundamental ICR: lower antenna-plasma coupling efficiency (by factor of about 1.5 times) and generation of high energy non-Maxwellian CX hydrogen atoms (with local energy E⊥H ≥1.0 keV). In the present paper, we analyze the obtained experimental results numerically using (i) newly developed 0-D transport code describing the process of plasma production with electron and ion collisional ionization in helium-hydrogen gas mixture and (ii) earlier developed 1-D Dispersion Relation Solver accounting for finite temperature effects and collision absorption mechanisms for all plasma species in addition to conventionally examined Landau/TTPM damping for electrons and cyclotron absorption for ions. The numerical study of plasma production in helium with minor hydrogen content in low and high toroidal magnetic fields is presented. The investigation of the excitation, conversion and absorption of plasma waves as function of BT-field suggests that only fast waves (FW) may give a crucial impact on antenna coupling and characteristics of the ICWC discharge using standard poloidally polarized ICRF antennas designed to couple RF power mainly to FW. The collisional (non-resonant) absorption by electrons and ions and IC absorption by resonant ions of minor concentration in low Te plasmas is studied at fundamental ICR and its high harmonics.

  12. Theory and simulation of the beam cyclotron instability.

    NASA Technical Reports Server (NTRS)

    Lampe, M.; Manheimer, W. M.; Mcbride, J. B.; Orens, J. H.; Papadopoulos, K.; Shanny, R.; Sudan, R. N.

    1972-01-01

    A theory of plasma beam cyclotron instability is developed on the basis of computer simulation experiments. The theory holds that at certain turbulence levels, electron cross-field diffusion which supresses the electron gyroresonances is created by turbulent wave-particle interactions in a plasma beam after a period of quasi-linear exponential development of turbulence. The stabilizing effect of Landau ion damping is noted. The behavior of cold and hot ions is discussed.

  13. Converting an AEG Cyclotron to H- Acceleration and Extraction

    NASA Astrophysics Data System (ADS)

    Ramsey, Fred; Carroll, Lewis; Rathmann, Tom; Huenges, Ernst; Bechtold, Matthias Mentler Volker

    2009-03-01

    Clinical Trials are under way to evaluate agents labeled with the nuclide 225Ac and its decay product 213Bi, in targeted alpha-immuno-therapy [1]. 225Ac can be produced on a medium-energy cyclotron via the nuclear reaction 226Ra(p,n)225Ac. To demonstrate proof-of-principle, a vintage AEG cyclotron, Model E33 [2], with an internal target, had been employed in a pilot production program at the Technical University of Munich (TUM). To enhance production capability and further support the clinical studies, the TUM facility has recently been refurbished and upgraded, adding a new external beam-line, automated target irradiation and transport systems, new laboratories, hot cells, etc. [3]. An improved high-power rotating target has been built and installed [4]. The AEG cyclotron itself has also been modified and upgraded to accelerate and extract H- ions. We have designed, built, and tested a new axial Penning-type ion source which is optimized for the production of H- ions. The ion source has continued to evolve through experiment and experience. Steady improvements in materials and mechanics have led to enhanced source stability, life-time, and H- production. We have also designed and built a precision H- charge-exchange beam-extraction system which is equipped with a vacuum lock. To fit within the tight mechanical constraint imposed by the narrow magnet gap, the system incorporates a novel chain-drive foil holder and foil-changer mechanism. The reconfigured cyclotron system has now been in operation for more than 1 year. Three long-duration target irradiations have been conducted. The most recent bombardment ran 160 continuous hours at a beam on target of ˜80 microamperes for a total yield of ˜70 milli-curies of 225Ac.

  14. Electron cyclotron current drive in DIII-D

    SciTech Connect

    Luce, T.C.; Lin-Liu, Y.R.; Lohr, J.M.; Petty, C.C.; Politzer, P.A.; Prater, R.; Harvey, R.W.; Giruzzi, G.; Rice, B.W.

    1999-05-01

    Clear measurements of the localized current density driven by electron cyclotron waves have been made on the DIII-D tokamak. Direct evidence of the current drive is seen on the internal magnetic field measurements by motional Stark effect spectroscopy. Comparison with theoretical calculations in the collisionless limit shows the experimental current drive exceeds the predictions by a substantial amount for currents driven near the half radius. In all cases the experimental current density profile is broader than the predicted one.

  15. Ion-beam-driven electrostatic ion cyclotron instabilities

    SciTech Connect

    Miura, A.; Okuda, H.; Ashour-Abdalla, M.

    1982-10-01

    We present results of numerical simulations on the electrostatic ion cyclotron instabilities driven by the ion beam parallel to the magnetic field. For the beam speed exceeding the thermal speed of background ions and the beam temperature much lower than the background ion temperature, it is found that the instability results in strong perpendicular heating and slowing down of parallel drift of the beam ions, leading to the saturation of the instability. Applications to plasma heating and space plasma physics are discussed.

  16. Compressibility and cyclotron damping in the oblique Alfven wave

    SciTech Connect

    Harmon, J.K. )

    1989-11-01

    Compressibility, magnetic compressibility, and damping rate are calculated for the obliquely propagating Alfven shear wave in high- and low-beta Vlasov plasmas. There is an overall increase in compressibility as beta is reduced from {beta} = 1 to {beta}{much lt}1. For high obliquity {theta} and low frequency ({omega} {much lt} {Omega}{sub p}) the compressibility C follows a k{sup 2} wave number dependence; for high {theta} and low {beta} the approximation C(k) {approx} k{sub n}{sup 2} {identical to} (kV{sub A}/{Omega}{sub p}){sup 2} holds for wave numbers up to the proton cyclotron resonance, where {Omega}{sub p} is the proton cyclotron frequency and V{sub A} is the Alfven velocity. Strong proton cyclotron damping sets in at k{sub n} of the order of unity; the precise k{sub n} position of the damping cutoff increases with decreasing {beta} and increasing {theta}. Hence compressibility can exceed unity near the damping cutoff for high-{theta} waves in a low-{beta} plasma. The magnetic compressibility of the oblique Alfven wave also has a k{sup 2} dependence and can reach a maximum value of the order of 10% at high wave number. It is shown that Alfven compressibility could be the dominant contributor to the near-Sun solar wind density fluctuation spectrum for k>10{sup {minus}2} km{sup {minus}1} and hence might cause some of the flattening at high wave number seen in radio scintillation measurements. This would also be consistent with the notion that the observed density spectrum inner scale is a signature of cyclotron damping.

  17. UC Berkeley's Adaptations to the Crisis of Public Higher Education in the US: Privatization? Commercialization? or Hybridization? Research & Occasional Paper Series: CSHE.17.13

    ERIC Educational Resources Information Center

    Breslauer, George W.

    2013-01-01

    The University of California at Berkeley now delivers more to the public of California than it ever has, and it does this on the basis of proportionally less funding by the State government than it has ever received. This claim may come as a surprise, since it is often said that Berkeley is in the process of privatizing, becoming less of a public…

  18. A Suzaku View of Cyclotron Line Sources and Candidates

    NASA Technical Reports Server (NTRS)

    Pottschmidt, K.; Suchy, S.; Rivers, E.; Rothschild, R. E.; Marcu, D. M.; Barragan, L.; Kuehnel, M.; Fuerst, F.; Schwarm, F.; Kreykenbohm, I.; Wilms, J.; Schoenherr, G.; Caballero, I.; Camero-Arranz, A.; Bodaghee, A.; Doroshenko, V.; Klochkov, D.; Santangelo, A.; Staubert, R.; Kretschmar, P.; Wilson-Hodge, C.; Finger, M. H.; Terada, Y.

    2012-01-01

    Seventeen accreting neutron star pulsars, mostly high mass X-ray binaries with half of them Be-type transients, are known to exhibit Cyclotron Resonance Scattering Features (CRSFs) in their X-ray spectra, with characteristic line energies from 10 to 60 keY. To date about two thirds of them, plus a few similar systems without known CRSFs, have been observed with Suzaku. We present an overview of results from these observations, including the discovery of a CRSF in the transient IA1118-61 and pulse phase resolved spectroscopy of OX 301-2. These observations allow for the determination of cyclotron line parameters to an unprecedented degree of accuracy within a moderate amount of observing time. This is important since these parameters vary - e.g., with orbital phase, pulse phase, or luminosity - depending on the geometry of the magnetic field of the pulsar and the properties of the accretion column at the magnetic poles. We briefly introduce a spectral model for CRSFs that is currently being developed and that for the first time is based on these physical properties. In addition to cyclotron line measurements, selected highlights from the Suzaku analyses include dip and flare studies, e.g., of 4U 1907+09 and Vela X-I, which show clumpy wind effects (like partial absorption and/or a decrease in the mass accretion rate supplied by the wind) and may also display magnetospheric gating effects.

  19. Fundamentals of the Cyclotron Up-Scattering Process

    SciTech Connect

    Ho, Cheng; Epstein, R.I.; Fenimore, E.E.

    1991-12-31

    Gamma-ray bursts (GRBs) remain an enigmatic astrophysical phenomenon some 20 years after their discovery. One of their unique characteristics is their continuum spectra which tend to be deficient in soft X-rays. Most of the energy of continuum emission comes from photons with energy above 100 keV (Epstein 1986). Following the recent detection of double absorption features in GB870303 and GB880205, and the interpretation of these features as the fundamental and first harmonic cyclotron lines great interest has been aroused in the mechanism of continuum emission in a strong magnetic field. In this paper, we describe some basic results of the production of continuum emission via up-scattering of low energy photons by relativistic electrons in a magnetic field. The dominant process is the cyclotron resonant scattering which we refer to as the Cyclotron Up-Scattering Process. See Ho and Epstein (1989a) for discussions on the non-magnetic (Compton) up-scattering process. A more detailed discussion of this work is presented in a separate paper (Ho, Epstein and Fenimore 1991).

  20. Fundamentals of the Cyclotron Up-Scattering Process

    SciTech Connect

    Ho, Cheng; Epstein, R.I.; Fenimore, E.E.

    1991-01-01

    Gamma-ray bursts (GRBs) remain an enigmatic astrophysical phenomenon some 20 years after their discovery. One of their unique characteristics is their continuum spectra which tend to be deficient in soft X-rays. Most of the energy of continuum emission comes from photons with energy above 100 keV (Epstein 1986). Following the recent detection of double absorption features in GB870303 and GB880205, and the interpretation of these features as the fundamental and first harmonic cyclotron lines great interest has been aroused in the mechanism of continuum emission in a strong magnetic field. In this paper, we describe some basic results of the production of continuum emission via up-scattering of low energy photons by relativistic electrons in a magnetic field. The dominant process is the cyclotron resonant scattering which we refer to as the Cyclotron Up-Scattering Process. See Ho and Epstein (1989a) for discussions on the non-magnetic (Compton) up-scattering process. A more detailed discussion of this work is presented in a separate paper (Ho, Epstein and Fenimore 1991).

  1. Linear analysis of ion cyclotron interaction in a multicomponent plasma

    NASA Technical Reports Server (NTRS)

    Gendrin, R.; Ashour-Abdalla, M.; Omura, Y.; Quest, K.

    1984-01-01

    The mechanism by which hot anisotropic protons generate electromagnetic ion cyclotron waves in a plasma containing cold H(+) and He(+) ions is quantitatively studied. Linear growth rates (both temporal and spatial) are computed for different plasma parameters: concentration, temperature,and anisotropy of cold He(+) ions and of hot protons. It is shown that: (1) for parameters typical of the geostationary altitude the maximum growth rates are not drastically changed when a small proportion (about 1 to 20 percent) of cold He(+) ions is present; (2) because of the important cyclotron absorption by thermal He(+) ions in the vicinity of the He(+) gyrofrequency, waves which could resonate with the bulk of the He(+) distribution cannot be generated. Therefore quasi-linear effects, in a homogeneous medium at least, cannot be responsible for the heating of He(+) ions which is often observed in conjunction with ion cyclotron waves. The variation of growth rate versus wave number is also studied for its importance in selecting suitable parameters in numerical simulation experiments.

  2. Project 8: Single-Electron Spectroscopy via Relativistic Cyclotron Radiation

    NASA Astrophysics Data System (ADS)

    de Viveiros, Luiz; Project 8 Collaboration

    2016-03-01

    The Project 8 experiment seeks to determine the neutrino mass via the precise measurement of the electron energy in beta decays. We have developed a novel technique called Cyclotron Radiation Emission Spectroscopy (CRES), which allows single electron detection and characterization through the measurement of cyclotron radiation emitted by magnetically-trapped electrons produced by a gaseous radioactive source. The advantages of this technique include scalability, excellent energy resolution, and low backgrounds. A prototype using a waveguide-coupled 83mKr source in a 1 T magnetic field was constructed, and used to demonstrate the viability of this technique. We have recently reported the first observation and measurement of single-electron cyclotron radiation, emitted by the internal conversion electrons (at 17 . 8keV and 30 . 4keV) released in the decay of 83mKr. We present the latest results of the ongoing prototype run, with a focus on signal detection and analysis techniques leading to an improved energy resolution of O (1eV) .

  3. Cryogenic system upgrade for the National Superconducting Cyclotron Laboratory

    SciTech Connect

    A. McCartney; V. Ganni; H. Laumer; D. Arenius; J. Creel; W. Chronis; K. Davidson

    2002-05-10

    The National Superconducting Cyclotron Laboratory (NSCL) is a National Science Foundation supported facility, with additional support from Michigan State University (MSU). The facility consists of two superconducting cyclotrons and over fifty individual cryostats, each containing several superconducting magnets that are used in the beam transport system. The facility also has a superconducting ion source and a large superconducting spectrograph. To support this facility we operated two helium refrigerators producing approximate 900W at 4.5K. In July of 1999, construction of a new beam analysis system, the A1900, was started. The laboratory was reconfigured to couple the two cyclotrons in series to enable the facility to produce higher intensity radioactive beams than previously possible in the stand-alone mode. In addition, the helium distribution system was upgraded with new transfer lines and a new distribution box. The new requirements increased the refrigeration load to more than 1 KW at 4.5K. To support this increased cryogenic load, the existing two helium cryogenic plants, were at best, marginal in capacity. This would have required both plants to run at full capacity, maximum efficiency and availability. To achieve higher reliability, availability, and process transient capacity for magnet cool down and filling, a decision was made to obtain a larger cryogenic plant to support the new system. The following paper describes the important aspects and capabilities of the new cryogenic system to accomplish this goal.

  4. Improving cancer treatment with cyclotron produced radionuclides. Progress report

    SciTech Connect

    Larson, S.M.; Finn, R.D.

    1992-08-04

    Our goal is to improve the scientific basis for tumor diagnosis, treatment and treatment follow-up based on the use of cyclotron produced radiotracers in oncology. The grant includes 3 interactive components: Radiochemistry/Cyclotron; Pharmacology; and Immunology. The radiochemistry group seeks to develop innovative cyclotron targetry, radiopharmaceuticals, and radiolabeled antibodies, which are then used to assess important unanswered questions in tumor pharmacology and immunology. Examples include selected positron emitting radionuclides, such as Iodine-124, and Ga-66; I-124, I-123, I-131 labeled iododeoxyuridine, C-11 colchicine, and antimetabolites, like C-11 methotrexate; and radiolabeled antibodies, 3F8, M195, A33, and MRK16 for application in the pharmacology and immunology projects. The pharmacology program studies tumor resistance to chemotherapy, particularly the phenomenon of multidrug resistance and the relationship between tumor uptake and retention and the tumor response for anti-metabolite drugs. The immunology program studies the physiology of antibody localization at the tissue level as the basis for novel approaches to improving tumor localization such as through the use of an artificial lymphatic system which mechanically reduces intratumoral pressures in tumors in vivo. Quantitative imaging approaches based on PET and SPECT in radioimmunotherapy are studied to give greater insight into the physiology of tumor localization and dosimetry.

  5. Electrostatic ion-cyclotron waves in a nonuniform magnetic field

    NASA Technical Reports Server (NTRS)

    Cartier, S. L.; Dangelo, N.; Merlino, R. L.

    1985-01-01

    The properties of electrostatic ion-cyclotron waves excited in a single-ended cesium Q machine with a nonuniform magnetic field are described. The electrostatic ion-cyclotron waves are generated in the usual manner by drawing an electron current to a small exciter disk immersed in the plasma column. The parallel and perpendicular (to B) wavelengths and phase velocities are determined by mapping out two-dimensional wave phase contours. The wave frequency f depends on the location of the exciter disk in the nonuniform magnetic field, and propagating waves are only observed in the region where f is approximately greater than fci, where fci is the local ion-cyclotron frequency. The parallel phase velocity is in the direction of the electron drift. From measurements of the plasma properties along the axis, it is inferred that the electron drift velocity is not uniform along the entire current channel. The evidence suggests that the waves begin being excited at that axial position where the critical drift velocity is first exceeded, consistent with a current-driven excitation mechanism.

  6. Electromagnetic ion beam instabilities - Growth at cyclotron harmonic wave numbers

    NASA Technical Reports Server (NTRS)

    Smith, Charles W.; Gary, S. Peter

    1987-01-01

    The linear theory of electromagnetic ion beam instabilities for arbitrary angles of propagation is studied, with an emphasis on the conditions necessary to generate unstable modes at low harmonics of the ion cyclotron resonance condition. The present results extend the analysis of Smith et al. (1985). That paper considered only the plasma parameters at a time during which harmonic wave modes were observed in the earth's foreshock. The parameters of that paper are used as the basis of parametric variations here to establish the range of beam properties which may give rise to observable harmonic spectra. It is shown that the growth rates of both left-hand and right-hand cyclotron harmonic instabilities are enhanced by an increase in the beam temperature anisotropy and/or the beam speed. Decreases in the beam density and/or the core-ion beta reduce the overall growth of the cyclotron harmonic instabilities but favor the growth of these modes over the growth of the nonresonant instability and thereby enhance the observability of the harmonics.

  7. RF control hardware design for CYCIAE-100 cyclotron

    NASA Astrophysics Data System (ADS)

    Yin, Zhiguo; Fu, Xiaoliang; Ji, Bin; Zhao, Zhenlu; Zhang, Tianjue; Li, Pengzhan; Wei, Junyi; Xing, Jiansheng; Wang, Chuan

    2015-11-01

    The Beijing Radioactive Ion-beam Facility project is being constructed by BRIF division of China Institute of Atomic Energy. In this project, a 100 MeV high intensity compact proton cyclotron is built for multiple applications. The first successful beam extraction of CYCIAE-100 cyclotron was done in the middle of 2014. The extracted proton beam energy is 100 MeV and the beam current is more than 20 μA. The RF system of the CYCIAE-100 cyclotron includes two half-wavelength cavities, two 100 kW tetrode amplifiers and power transmission line systems (all above are independent from each other) and two sets of Low Level RF control crates. Each set of LLRF control includes an amplitude control unit, a tuning control unit, a phase control unit, a local Digital Signal Process control unit and an Advanced RISC Machines based EPICS IOC unit. These two identical LLRF control crates share one common reference clock and take advantages of modern digital technologies (e.g. DSP and Direct Digital Synthesizer) to achieve closed loop voltage and phase regulations of the dee-voltage. In the beam commission, the measured dee-voltage stability of RF system is better than 0.1% and phase stability is better than 0.03°. The hardware design of the LLRF system will be reviewed in this paper.

  8. The cyclotron laboratory and the RFQ accelerator in Bern

    SciTech Connect

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Weber, M.; Scampoli, P.; Bremen, K. von

    2013-07-18

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  9. The cyclotron laboratory and the RFQ accelerator in Bern

    NASA Astrophysics Data System (ADS)

    Braccini, S.; Ereditato, A.; Kreslo, I.; Nirkko, M.; Scampoli, P.; von Bremen, K.; Weber, M.

    2013-07-01

    Two proton accelerators have been recently put in operation in Bern: an 18 MeV cyclotron and a 2 MeV RFQ linac. The commercial IBA 18/18 cyclotron, equipped with a specifically conceived 6 m long external beam line ending in a separate bunker, will provide beams for routine 18-F and other PET radioisotope production as well as for novel detector, radiation biophysics, radioprotection, radiochemistry and radiopharmacy developments. The accelerator is embedded into a complex building hosting two physics laboratories and four Good Manufacturing Practice (GMP) laboratories. This project is the result of a successful collaboration between the Inselspital, the University of Bern and private investors, aiming at the constitution of a combined medical and research centre able to provide the most cutting-edge technologies in medical imaging and cancer radiation therapy. The cyclotron is complemented by the RFQ with the primary goals of elemental analysis via Particle Induced Gamma Emission (PIGE), and the detection of potentially dangerous materials with high nitrogen content using the Gamma-Resonant Nuclear Absorption (GRNA) technique. In this context, beam instrumentation devices have been developed, in particular an innovative beam profile monitor based on doped silica fibres and a setup for emittance measurements using the pepper-pot technique. On this basis, the establishment of a proton therapy centre on the campus of the Inselspital is in the phase of advanced study.

  10. Foil changer for the Chalk River superconducting cyclotron

    SciTech Connect

    Hoffmann, C.R.; Kilborn, R.I.; Mouris, J.E.; Proulx, D.R.; Weaver, J.F.

    1985-10-01

    Capture of an injected beam in the Chalk River superconducting cyclotron requires that a carbon stripping foil be accurately placed in a dee to intercept the incoming beam. Foil radial position must be precisely adjustable and foils must be easily replaced. A foil changing apparatus has been designed, built and tested to meet these requirements. The main components are a supply magazine, a transport system, and unloading and loading mechanisms. The magazine is on top of the cyclotron. It holds 300 foils and can be isolated from machine vacuum for refilling. Each foil is mounted on a stainless steel frame. A stainless steel roller chain fitted with 33 copper sleeves (shrouds) carries foils, one per shroud, down a dee stem to the midplane. A 12-bit absolute optical shaft encoder senses foil position. To replace a foil a shroud is positioned at the top of the cyclotron, a foil is removed, and another is transferred from the magazine to the empty shroud. Three stepping motors and associated electronics provide mechanical drive and are interfaced with a CAMAC control system.

  11. An Analysis of Applicants Admitted to the Master's Program of the Graduate School of Business Administration at Berkeley.

    ERIC Educational Resources Information Center

    Pieper, W. C., Jr.

    Charged with developing rigorous and exacting selection procedures, the professional schools at the University of California, Berkeley, must continually evaluate their programs and students. The aim of this study was to identify on the basis of past experience those factors which have been the best predictors of a student's ability to succeed in…

  12. Assessing Information Literacy among Undergraduates: A Discussion of the Literature and the University of California-Berkeley Assessment Experience.

    ERIC Educational Resources Information Center

    Maughan, Patricia Davitt

    2001-01-01

    Since 1994, the Teaching Library at the University of California-Berkeley has conducted an ongoing Survey of Information Literacy Competencies in selected academic departments to measure the "lower-order" information literacy skills of graduating seniors. The survey reveals that students think they know more about accessing information and…

  13. Higher Retail Prices of Sugar-Sweetened Beverages 3 Months After Implementation of an Excise Tax in Berkeley, California

    PubMed Central

    Rojas, Nadia; Grummon, Anna H.; Madsen, Kristine A.

    2015-01-01

    Objectives. We assessed the short-term ability to increase retail prices of the first US 1-cent-per-ounce excise tax on the distribution of sugar-sweetened beverages (SSBs), which was implemented in March 2015 by Berkeley, California. Methods. In 2014 and 2015, we examined pre- to posttax price changes of SSBs and non-SSBs in a variety of retailers in Berkeley and in the comparison cities Oakland and San Francisco, California. We examined price changes by beverage, brand, size, and retailer type. Results. For smaller beverages (≤ 33.8 oz), price increases (cents/oz) in Berkeley relative to those in comparison cities were 0.69 (95% confidence interval [CI] = 0.36, 1.03) for soda, 0.47 (95% CI = 0.08, 0.87) for fruit-flavored beverages, and 0.47 (95% CI = 0.25, 0.69) for SSBs overall. For 2-liter bottles and multipacks of soda, relative price increases were 0.46 (95% CI = 0.03, 0.89) and 0.49 (95% CI = 0.21, 0.77). We observed no relative price increases for nontaxed beverages overall. Conclusions. Approximately 3 months after the tax was implemented, SSB retail prices increased more in Berkeley than in nearby cities, marking a step in the causal pathway between the tax and reduced SSB consumption. PMID:26444622

  14. Undergraduate Research Participation at the University of California, Berkeley. Research & Occasional Paper Series: CSHE.17.08

    ERIC Educational Resources Information Center

    Berkes, Elizabeth

    2008-01-01

    Although the University of California, Berkeley has increased efforts to involve undergraduates in scientific research, little data exists regarding the number of undergraduate researchers. The University of California Undergraduate Experience Survey (UCUES) presents an opportunity to investigate the extent of undergraduate research involvement at…

  15. 77 FR 75448 - Welded Tube-Berkeley Including On-Site Leased Workers From Snelling, Aerotek and Express...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-20

    ... Register on October 29, 2012 (77 FR 65583). At the request of South Carolina State, the Department reviewed... Employment and Training Administration Welded Tube--Berkeley Including On-Site Leased Workers From Snelling... Worker Adjustment Assistance on October 10, 2012, applicable to workers of Welded...

  16. Doing Much More with Less: Implementing Operational Excellence at UC Berkeley. Research & Occasional Paper Series: CSHE.10.13

    ERIC Educational Resources Information Center

    Szeri, Andrew J.; Lyons, Richard; Huston, Peggy; Wilton, John

    2013-01-01

    Universities are undergoing historic change, from the sharp downward shift in government funding to widespread demands to document performance. At the University of California Berkeley, this led to an operational change effort unlike any the university had ever attempted, dubbed Operational Excellence. The authors describe their experiences…

  17. Summary Report on 2011 CO2 Geologic Sequestration & Water Resources Workshop, Berkeley, June 1-2, 2011

    EPA Science Inventory

    To help with the research planning and prioritization, EPA and Lawrence Berkeley National Laboratory (LBNL) jointly hosted a workshop on “CO2 Geologic Sequestration and Water Resources.” The objective of the workshop, held at LBNL on June 1–2, 2011, was to evaluate the current s...

  18. Backward mode of the ion-cyclotron wave in a semi-bounded magnetized Lorentzian plasma

    SciTech Connect

    Ki, Dae-Han; Jung, Young-Dae

    2012-08-15

    The backward modes of the surface ion-cyclotron wave are investigated in a semi-bounded magnetized Lorentzian plasma. The dispersion relation of the backward mode of the surface ion-cyclotron wave is obtained using the specular reflection boundary condition with the plasma dielectric function. The result shows that the nonthermal effect suppresses the wave frequency as well as the group velocity of the surface ion-cyclotron wave. It is also found that the nonthermal effect on the surface ion-cyclotron wave increases with an increase of the wave number. In addition, it is found that the propagation domain of the surface ion-cyclotron wave increases with an increase of the ratio of the electron plasma frequency to the electron gyrofrequency. It is also found that the nonthermal effect increases the propagation domain of the surface ion-cyclotron wave in a semi-bounded magnetized Lorentzian plasma.

  19. Considerations, measurements and logistics associated with low-energy cyclotron decommissioning

    SciTech Connect

    Sunderland, J. J.; Erdahl, C. E.; Bender, B. R.; Sensoy, L.; Watkins, G. L.

    2012-12-19

    The University of Iowa's 20-year-old 17 MeV Scanditronix cyclotron underwent decommissioning in the summer of 2011. To satisfy local, state and federal regulations defining removal, transportation and long-term safe and environmentally secure disposal of the 22 ton activated cyclotron, a series of nuclear spectroscopic measurements were performed to characterize the nature and extent of proton and neutron activation of the 22-ton cyclotron, its associated targets, and the concrete wall that was demolished to remove the old cyclotron. Neutron activation of the concrete wall was minimal and below exempt concentrations resulting in standard landfill disposal. The cyclotron assessment revealed the expected array of short and medium-lived radionuclides. Subsequent calculations suggest that meaningful levels residual activity will have decayed virtually to background after 15 years, with the total residual activity of the entire cyclotron dropping below 37 MBq (1 mCi).

  20. Whistler and Alfvén Mode Cyclotron Masers in Space

    NASA Astrophysics Data System (ADS)

    Trakhtengerts, V. Y.; Rycroft, M. J.

    2012-10-01

    Preface; 1. Introduction; 2. Basic theory of cyclotron masers (CMs); 3. Linear theory of the cyclotron instability (CI); 4. Backward wave oscillator (BWO) regime in CMs; 5. Nonlinear cyclotron wave-particle interactions for a quasi-monochromatic wave; 6. Nonlinear interaction of quasi-monochromatic whistler mode waves with gyroresonant electrons in an in homogeneous plasma; 7. Wavelet amplification in an inhomogeneous plasma; 8. Quasi-linear theory of cyclotron masers; 9. Nonstationary generation regimes, and modulation effects; 10. ELF/VLF noise-like emissions and electrons in the Earth's radiation belts; 11. Generation of discrete ELF/VLF whistler mode emissions; 12. Cyclotron instability of the proton radiation belts; 13. Cyclotron masers elsewhere in the solar system and in laboratory plasma devices; Epilogue; Glossary of terms; List of acronyms; References; Index.

  1. Considerations, measurements and logistics associated with low-energy cyclotron decommissioning

    NASA Astrophysics Data System (ADS)

    Sunderland, J. J.; Erdahl, C. E.; Bender, B. R.; Sensoy, L.; Watkins, G. L.

    2012-12-01

    The University of Iowa's 20-year-old 17 MeV Scanditronix cyclotron underwent decommissioning in the summer of 2011. To satisfy local, state and federal regulations defining removal, transportation and long-term safe and environmentally secure disposal of the 22 ton activated cyclotron, a series of nuclear spectroscopic measurements were performed to characterize the nature and extent of proton and neutron activation of the 22-ton cyclotron, its associated targets, and the concrete wall that was demolished to remove the old cyclotron. Neutron activation of the concrete wall was minimal and below exempt concentrations resulting in standard landfill disposal. The cyclotron assessment revealed the expected array of short and medium-lived radionuclides. Subsequent calculations suggest that meaningful levels residual activity will have decayed virtually to background after 15 years, with the total residual activity of the entire cyclotron dropping below 37 MBq (1 mCi).

  2. Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron

    NASA Astrophysics Data System (ADS)

    Hojo, S.; Katagiri, K.; Nakao, M.; Sugiura, A.; Muramatsu, M.; Noda, A.; Okada, T.; Takahashi, Y.; Komiyama, A.; Honma, T.; Noda, K.

    2014-02-01

    The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C4+ ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8-10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C4+, for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source.

  3. Status of a compact electron cyclotron resonance ion source for National Institute of Radiological Sciences-930 cyclotron.

    PubMed

    Hojo, S; Katagiri, K; Nakao, M; Sugiura, A; Muramatsu, M; Noda, A; Okada, T; Takahashi, Y; Komiyama, A; Honma, T; Noda, K

    2014-02-01

    The Kei-source is a compact electron cyclotron resonance ion source using only permanent magnets and a frequency of 10 GHz. It was developed at the National Institute of Radiological Sciences (NIRS) for producing C(4+) ions oriented for high-energy carbon therapy. It has also been used as an ion source for the NIRS-930 cyclotron. Its microwave band region for the traveling-wave-tube amplifier and maximum output power are 8-10 GHz and 350 W, respectively. Since 2006, it has provided various ion beams such as proton, deuteron, carbon, oxygen, and neon with sufficient intensity (200 μA for proton and deuteron, 50 μA for C(4+), for example) and good stability for radioisotope production, tests of radiation damage, and basic research experiments. Its horizontal and vertical emittances were measured using a screen monitor and waist-scan. The present paper reports the current status of the Kei-source. PMID:24593538

  4. Laboratory modeling of pulsed regimes of electron cyclotron instabilities

    NASA Astrophysics Data System (ADS)

    Golubev, S. V.; Mansfeld, D. A.; Viktorov, M. E.; Izotov, I. V.; Vodopyanov, A. V.; Demekhov, A. G.; Shalashov, A. G.

    2012-04-01

    One of the most interesting electron cyclotron resonance (ECR) manifestations is the generation of bursts of electromagnetic radiation that are related to the explosive growth of cyclotron instabilities of the magnetoactive plasma confined in magnetic traps of various kinds and that are accompanied by particle precipitations from the trap. Such phenomena are observed in a wide range of plasma parameters under various conditions: in the magnetospheres of the Earth and planets, in solar coronal loops, and in laboratory magnetic traps. We demonstrate the use of a laboratory setup based on a magnetic mirror trap with plasma sustained by a gyrotron radiation under ECR conditions for investigation of the cyclotron instabilities similar to the ones which take place in space plasmas. Two regimes of the cyclotron instability are studied. In the first place, quasi-periodic pulsed precipitation of energetic electrons from the trap, accompanied by microwave bursts at frequencies below the electron gyrofrequency in the center of the trap, is detected. The study of the microwave plasma emission and the energetic electrons precipitated from the trap shows that the precipitation is related to the excitation of whistlers propagating nearly parallel to the trap axis. The observed instability has much in common with phenomena in space magnetic traps, such as radiation belts of magnetized planets and solar coronal loops. Such regimes have much in common with the quasi-periodic VLF radiation in the Earth's inner magnetosphere (with periods of T ~ 100 s) and can also be met in solar flaring loops and at other space objects. In the second place, we have detected and investigated quasi-periodic series of pulsed energetic electron precipitations in the decaying plasma of a pulsed ECR discharge in a mirror axisymmetric magnetic trap. The observed particle ejections from the trap are interpreted as the result of resonant interaction between energetic electrons and a slow extraordinary wave

  5. Observation of a high-confinement regime in a tokamak plasma with ion cyclotron resonance heating

    NASA Astrophysics Data System (ADS)

    Steinmetz, K.; Noterdaeme, J.-M.; Wagner, F.; Wesner, F.; Bäumler, J.; Becker, G.; Bosch, H. S.; Brambilla, M.; Braun, F.; Brocken, H.; Eberhagen, A.; Fritsch, R.; Fussmann, G.; Gehre, O.; Gernhardt, J.; v. Gierke, G.; Glock, E.; Gruber, O.; Haas, G.; Hofmann, J.; Hofmeister, F.; Izvozchikov, A.; Janeschitz, G.; Karger, F.; Keilhacker, M.; Klüber, O.; Kornherr, M.; Lackner, K.; Lisitano, G.; van Mark, E.; Mast, F.; Mayer, H. M.; McCormick, K.; Meisel, D.; Mertens, V.; Müller, E. R.; Murmann, H.; Niedermeyer, H.; Poschenrieder, W.; Puri, S.; Rapp, H.; Röhr, H.; Ryter, F.; Schmitter, K.-H.; Schneider, F.; Setzensack, C.; Siller, G.; Smeulders, P.; Söldner, F.; Speth, E.; Steuer, K.-H.; Vollmer, O.; Wedler, H.; Zasche, D.

    1987-01-01

    The H mode in ion cyclotron-resonance-heated plasmas has been investigated with and without additional neutral beam injection. Ion cyclotron-resonance heating can cause the transition into a high-confinement regime (H mode) in combination with beam heating. The H mode, however, has also been realized-for the first time-with ion cyclotron-resonance heating alone in the D (H)-hydrogen minority scheme at an absorbed rf power of 1.1 MW.

  6. Cyclotron harmonic lines in magnetic fluctuations of spiralling electrons in plasmas

    NASA Technical Reports Server (NTRS)

    Golubiatnikov, G.; Stenzel, R. L.

    1993-01-01

    The magnetic fluctuation spectrum in a magnetoplasma containing energetic electrons is observed to exhibit many lines at the cyclotron harmonics. It is shown that these fluctuations are neither due to cyclotron radiation nor due to velocity-space instabilities but due to coherent solenoidal fields produced by electron cyclotron orbits and excited by thermal fluctuations. Such line spectra, observed in discharges and beam-plasma systems, may be useful for precise magnetic field diagnostics in plasmas.

  7. Adsorption of Dissolved Metals in the Berkeley Pit using Thiol-Functionalized Self-Assembled Monolayers on Mesoporous Supports (Thiol-SAMMS)

    SciTech Connect

    Betancourt, Amaury P.; Mattigod, Shas V.; Wellman, Dawn M.

    2010-03-07

    The Berkeley Pit in Butte, Montana, is heavily contaminated with dissolved metals. Adsorption and extraction of these metals can be accomplished through the use of a selective adsorbent. For this research, the adsorbent used was thiol-functionalized Self-Assembled Monolayers on Mesoporous Supports (thiol-SAMMS), which was developed at Pacific Northwest National Laboratory (PNNL). Thiol-SAMMS selectively binds to numerous types of dissolved metals. The objective of this research was to evaluate the loading and kinetics of aluminum, beryllium, copper, and zinc on thiol-SAMMS. For the loading tests, a series of Berkeley Pit water to thiol-SAMMS ratios (mL:g) were tested. These ratios were 1000:1, 500:1, 100:1, and 50:1. Berkeley Pit water is acidic (pH {approx} 2.5). This can affect the performance of SAMMS materials. Therefore, the effect of pH was evaluated by conducting parallel series of loading tests wherein the Berkeley Pit water was neutralized before or after addition of thiol-SAMMS, and a series of kinetics tests wherein the Berkeley Pit water was neutralized before addition of thiol-SAMMS for the first test and was not neutralized for the second test. For the kinetics tests, one Berkeley Pit water to thiol-SAMMS ratio was tested, which was 2000:1. The results of the loading and kinetics tests suggest that a significant decrease in dissolved metal concentration at Berkeley Pit could be realized through neutralization of Berkeley Pit water. Thiol-SAMMS technology has a limited application under the highly acidic conditions posed by the Berkeley Pit. However, thiol-SAMMS could provide a secondary remedial technique which would complete the remedial system and remove dissolved metals from the Berkeley Pit to below drinking water standards.

  8. Microwave emission related to cyclotron instabilities in a minimum-B electron cyclotron resonance ion source plasma

    NASA Astrophysics Data System (ADS)

    Izotov, I.; Tarvainen, O.; Mansfeld, D.; Skalyga, V.; Koivisto, H.; Kalvas, T.; Komppula, J.; Kronholm, R.; Laulainen, J.

    2015-08-01

    Electron cyclotron resonance ion sources (ECRIS) have been essential in the research and applications of nuclear physics over the past 40 years. They are extensively used in a wide range of large-scale accelerator facilities for the production of highly charged heavy ion beams of stable and radioactive elements. ECRISs are susceptible to kinetic instabilities due to resonance heating mechanism leading to anisotropic electron velocity distribution function. Instabilities of cyclotron type are a proven cause of frequently observed periodic bursts of ‘hot’ electrons and bremsstrahlung, accompanied with emission of microwave radiation and followed by considerable drop of multiply charged ions current. Detailed studies of the microwave radiation associated with the instabilities have been performed with a minimum-B 14 GHz ECRIS operating on helium, oxygen and argon plasmas. It is demonstrated that during the development of cyclotron instability ‘hot’ electrons emit microwaves in sub-microsecond scale bursts at temporally descending frequencies in the 8-15 GHz range with two dominant frequencies of 11.09 and 12.59 GHz regardless of ECRIS settings i.e. magnetic field strength, neutral gas pressure or species and microwave power. The experimental data suggest that the most probable excited plasma wave is a slow extraordinary Z-mode propagating quasi-longitudinally with respect to the external magnetic field.

  9. Linear and nonlinear physics of the magnetoacoustic cyclotron instability of fusion-born ions in relation to ion cyclotron emission

    SciTech Connect

    Carbajal, L. Cook, J. W. S.; Dendy, R. O.; Chapman, S. C.

    2014-01-15

    The magnetoacoustic cyclotron instability (MCI) probably underlies observations of ion cyclotron emission (ICE) from energetic ion populations in tokamak plasmas, including fusion-born alpha-particles in JET and TFTR [Dendy et al., Nucl. Fusion 35, 1733 (1995)]. ICE is a potential diagnostic for lost alpha-particles in ITER; furthermore, the MCI is representative of a class of collective instabilities, which may result in the partial channelling of the free energy of energetic ions into radiation, and away from collisional heating of the plasma. Deep understanding of the MCI is thus of substantial practical interest for fusion, and the hybrid approximation for the plasma, where ions are treated as particles and electrons as a neutralising massless fluid, offers an attractive way forward. The hybrid simulations presented here access MCI physics that arises on timescales longer than can be addressed by fully kinetic particle-in-cell simulations and by analytical linear theory, which the present simulations largely corroborate. Our results go further than previous studies by entering into the nonlinear stage of the MCI, which shows novel features. These include stronger drive at low cyclotron harmonics, the re-energisation of the alpha-particle population, self-modulation of the phase shift between the electrostatic and electromagnetic components, and coupling between low and high frequency modes of the excited electromagnetic field.

  10. Linear and nonlinear physics of the magnetoacoustic cyclotron instability of fusion-born ions in relation to ion cyclotron emission

    NASA Astrophysics Data System (ADS)

    Carbajal, L.; Dendy, R. O.; Chapman, S. C.; Cook, J. W. S.

    2014-01-01

    The magnetoacoustic cyclotron instability (MCI) probably underlies observations of ion cyclotron emission (ICE) from energetic ion populations in tokamak plasmas, including fusion-born alpha-particles in JET and TFTR [Dendy et al., Nucl. Fusion 35, 1733 (1995)]. ICE is a potential diagnostic for lost alpha-particles in ITER; furthermore, the MCI is representative of a class of collective instabilities, which may result in the partial channelling of the free energy of energetic ions into radiation, and away from collisional heating of the plasma. Deep understanding of the MCI is thus of substantial practical interest for fusion, and the hybrid approximation for the plasma, where ions are treated as particles and electrons as a neutralising massless fluid, offers an attractive way forward. The hybrid simulations presented here access MCI physics that arises on timescales longer than can be addressed by fully kinetic particle-in-cell simulations and by analytical linear theory, which the present simulations largely corroborate. Our results go further than previous studies by entering into the nonlinear stage of the MCI, which shows novel features. These include stronger drive at low cyclotron harmonics, the re-energisation of the alpha-particle population, self-modulation of the phase shift between the electrostatic and electromagnetic components, and coupling between low and high frequency modes of the excited electromagnetic field.

  11. Correlation Between Radon Outgassing and Seismic Activity Along the Hayward Fault Near Berkeley, California

    NASA Astrophysics Data System (ADS)

    Holtmann-Rice, D.; Cuff, K.

    2003-12-01

    Results from previous studies indicate that radon concentration values are significantly higher over selected sections of the Hayward fault than adjacent areas. This phenomenon is believed to be attributed to the presence of abundant fractures in rock associated with the fault, which act as pathways for radon as it migrates from depth towards the earth?s surface. In an attempt to determine whether or not a relationship exists between seismicity along the fault, the production of microfractures, and emanation of radon, a radon outgassing monitoring study was conducted along an active section of the Hayward fault in Berkeley, California. The study was carried out by using an alphaMETER 611, which is a device capable of accurately measuring radon concentrations every 15 minutes. The alphaMETER was placed at the bottom of a sealed one meter deep well, in close proximity to a section of the Hayward fault located along the northwestern face of the Berkeley Hills. Once per week for several months data collected by the alphaMETER was downloaded into a laptop computer. Data from the alphaMETER was then compared with seismic data recorded by local seismometers to see if any correlation existed. A general correlation between variation in radon concentration and the occurrence of small earthquakes was found. Significant peaks in radon concentration were observed within an approximately one week period before the occurrence of small earthquakes. Concentration values then decreased dramatically just prior to and during periods when the earthquakes occurred. Such correlation is very similar to that recently observed in association with a magnitude five earthquake along the Anatolian Fault, reported by geoscientists working in Turkey using similar instrumentation (Inan, 2003, personal communication). The most plausible explanation for the observed correlation is as follows: 1) prior to a given earthquake, stress build up within a particular fault region leads to the formation of

  12. Tritium Exposure Reconstruction Using Tree Rings at Lawrence Berkeley National Laboratory

    NASA Astrophysics Data System (ADS)

    Love, A. H.; Hunt, J. R.; Knezovich, J. P.

    2002-12-01

    There are numerous instances where historical exposures to contaminants can determine future health impacts, but limited means exist to reconstruct those exposures from current measurements and models. The National Tritium Labeling Facility at Lawrence Berkeley National Laboratory (LBNL) has released tritiated water into the atmosphere through an adjacent stack since 1969. Some members of the surrounding community are concerned about potential health effects from the emissions and have questioned the accuracy and thoroughness of reported historical release quantities and environmental monitoring. A grove of Eucalyptus globulus surround the emission stack and were used to reconstruct historical exposure levels. Previous studies have demonstrated that plants can be reliably used as passive monitors for tritiated water, as well as many other contaminants. Because trees can sequester tritium into wood during photosynthesis, a tree provides a temporal variation of exposure at least on an annual basis. Milligram-sized samples of wood from cores were measured for carbon-14 and tritium using accelerator mass spectrometry. The carbon-14 measurements were matched with bomb curve levels of carbon-14 to independently assess the age of the wood used for organically bound tritium measurements. The tritium exposure reconstruction was consistent with annual exposure monitoring and release quantities reported by LBNL over the last 30 years. Because this location has an episodic release pattern and complex topographic and meteorological variation, the historical assessment from these environmental measurements is likely to have less uncertainty than mathematical modeling efforts.

  13. UC Berkeley Nuclear Engineering Curriculum and Research Enhancement. Final report, February 14, 1993--February 14, 1995

    SciTech Connect

    Fowler, T.K.; Peterson, P.F.

    1995-05-11

    This is a report for the 2/14/93 to 2/14/95 period of the five-year program proposed and initiated in 1992, for curriculum and research enhancement for the Department of Nuclear Engineering at the University of California, Berkeley. The program is designed to strengthen the departmental academic infrastructure and improve the education breadth of nuclear engineering students. The DOE funds have supported scholarships and a novel educational program which includes summer coursework at the Diablo Canyon Nuclear Power Plant. The summer course provides an important introduction to reactor safety and operations to students who will in the future be responsible for running many of our existing nuclear power plants. The work was funded under DOE contract DE-FG0393ER75856, with a matching gift to the Department from the Pacific Gas and Electric Company (PG&E). The program described in the original grant proposal has been successful implemented with an enthusiastic response from our students and faculty. The program consisted of two parts, one for innovative additions to our curriculum funded by the DOE, and the other for distinguished lectureships and support for basic research funded by gifts from PG&E.

  14. Ernest Orlando Lawrence Berkeley National Laboratory institutional plan, FY 1996--2001

    SciTech Connect

    1995-11-01

    The FY 1996--2001 Institutional Plan provides an overview of the Ernest Orlando Lawrence Berkeley National Laboratory mission, strategic plan, core business areas, critical success factors, and the resource requirements to fulfill its mission in support of national needs in fundamental science and technology, energy resources, and environmental quality. The Laboratory Strategic Plan section identifies long-range conditions that will influence the Laboratory, as well as potential research trends and management implications. The Core Business Areas section identifies those initiatives that are potential new research programs representing major long-term opportunities for the Laboratory, and the resources required for their implementation. It also summarizes current programs and potential changes in research program activity, science and technology partnerships, and university and science education. The Critical Success Factors section reviews human resources; work force diversity; environment, safety, and health programs; management practices; site and facility needs; and communications and trust. The Resource Projections are estimates of required budgetary authority for the Laboratory`s ongoing research programs. The Institutional Plan is a management report for integration with the Department of Energy`s strategic planning activities, developed through an annual planning process. The plan identifies technical and administrative directions in the context of the national energy policy and research needs and the Department of Energy`s program planning initiatives. Preparation of the plan is coordinated by the Office of Planning and Communications from information contributed by the Laboratory`s scientific and support divisions.

  15. Surficial geologic map of the Charleston region, Berkeley, Charleston, Colleton, Dorchester, and Georgetown Counties, South Carolina

    USGS Publications Warehouse

    Weems, Robert E.; Lewis, William C.; Lemon, Earl M., Jr.

    2014-01-01

    This map portrays the surface and shallow subsurface geology of the greater Charleston, S.C. region east of 80°30′ west and south of 33°15′ north. The region covers the entirety of Charleston County and portions of Berkeley, Colleton, Dorchester, and Georgetown Counties. Units locally exposed at the surface range in age from middle Eocene to Holocene, but most of the area is covered by Quaternary interglacial deposits. These are, from oldest to youngest, the Okefenokee, Waccamaw(?), Penholoway, Ladson, Ten Mile Hill, and Wando Formations and the Silver Bluff beds. Two cross sections, one running southeast from Harleyville to the coastline on James Island and the other running along the coastal barrier islands from the town of Edisto Beach to the northeast end of Bull Island at the southwest edge of Bull Bay, portray the complex geometry of the Paleogene and Neogene marine units that directly lie beneath the Quaternary units. These older units include the Santee Limestone, Tupelo Bay, Parkers Ferry, Ashley, Chandler Bridge, Edisto, Parachucla, and Marks Head Formations, the Goose Creek Limestone, and the Raysor Formation. The estimated locations of deeply buried active basement faults are shown which are responsible for ongoing modern seismicity in the Charleston, S.C. area.

  16. The SEMATECH Berkeley MET: extending EUV learning to 16-nm half pitch

    SciTech Connect

    Anderson, Christopher N.; Baclea-an, Lorie Mae; Denham, Paul E.; George, Simi; Goldberg, Kenneth A.; Jones, Michael; Smith, Nathan; Wallow, Thomas; Montgomery, Warren; Naulleau, Patrick P.

    2011-03-18

    Several high-performing resists identified in the past two years have been exposed at the 0.3-numerical-aperture (NA) SEMATECH Berkeley Microfield Exposure Tool (BMET) with an engineered dipole illumination optimized for 18-nm half pitch. Five chemically amplified platforms were found to support 20-nm dense patterning at a film thickness of approximately 45 nm. At 19-nm half pitch, however, scattered bridging kept all of these resists from cleanly resolving larger areas of dense features. At 18-nm half pitch, none of the resists were are able to cleanly resolve a single line within a bulk pattern. With this same illumination a directly imageable metal oxide hardmask showed excellent performance from 22-nm half pitch to 17-nm half pitch, and good performance at 16-nm half pitch, closely following the predicted aerial image contrast. This indicates that observed limitations of the chemically amplified resists are indeed coming from the resist and not from a shortcoming of the exposure tool. The imageable hardmask was also exposed using a Pseudo Phase-Shift-Mask technique and achieved clean printing of 15-nm half pitch lines and modulation all the way down to the theoretical 12.5-nm resolution limit of the 0.3-NA SEMATECH BMET.

  17. The Berkeley Low Background Facility and the Black Hills State University Underground Campus at SURF

    NASA Astrophysics Data System (ADS)

    Thomas, Keenan; Mount, Brianna; Lesko, Kevin; Norman, Eric; Smith, Alan; Poon, Alan; Chan, Yuen-Dat

    2015-10-01

    The Berkeley Low Background Facility at LBNL provides a variety of low background gamma spectroscopy services to a variety of projects and experiments. It operates HPGe spectrometers in two unique facilities: a surface low background lab at LBNL and underground (4300 m.w.e.) at the Sanford Underground Research Facility in Lead, SD. A large component of the measurements performed by the BLBF are for ultralow background experiments concerned with U, Th, K, and other radioisotopes within candidate construction materials to be used to construct sensitive detectors, such as those studying dark matter or neutrinos. The BLBF also makes a variety of environmental measurements in search of other radioisotopes, such as fallout from the Fukushima nuclear power plant accident in 2011 and other radioisotope monitoring activities. A general overview of the services and facilities will be presented. In 2015, the BLBF will be relocating its underground counting stations to a new, dedicated space on the 4850L of SURF. The Black Hills State University Underground Campus will host several low background counting stations and operate in a coordinated manner to provide low background measurements to the scientific community. An overview and description of the BHUC will be presented.

  18. The SEMATECH Berkeley MET pushing EUV development beyond 22-nm half pitch

    SciTech Connect

    Naulleau, P.; Anderson, C. N.; Backlea-an, L.-M.; Chan, D.; Denham, P.; George, S.; Goldberg, K. A.; Hoef, B.; Jones, G.; Koh, C.; La Fontaine, B.; McClinton, B.; Miyakawa, R.; Montgomery, W.; Rekawa, S.; Wallow, T.

    2010-03-18

    Microfield exposure tools (METs) play a crucial role in the development of extreme ultraviolet (EUV) resists and masks, One of these tools is the SEMATECH Berkeley 0.3 numerical aperture (NA) MET, Using conventional illumination this tool is limited to approximately 22-nm half pitch resolution. However, resolution enhancement techniques have been used to push the patterning capabilities of this tool to half pitches of 18 nm and below, This resolution was achieved in a new imageable hard mask which also supports contact printing down to 22 nm with conventional illumination. Along with resolution, line-edge roughness is another crucial hurdle facing EUV resists, Much of the resist LER, however, can be attributed to the mask. We have shown that intenssionally aggressive mask cleaning on an older generation mask causes correlated LER in photoresist to increase from 3.4 nm to 4,0 nm, We have also shown that new generation EUV masks (100 pm of substrate roughness) can achieve correlated LER values of 1.1 nm, a 3x improvement over the correlated LER of older generation EUV masks (230 pm of substrate roughness), Finally, a 0.5-NA MET has been proposed that will address the needs of EUV development at the 16-nm node and beyond, The tool will support an ultimate resolution of 8 nm half-pitch and generalized printing using conventional illumination down to 12 nm half pitch.

  19. The Berkeley Transient Classification Pipeline: Deriving Real-time Knowledge from Time-domain Surveys

    NASA Astrophysics Data System (ADS)

    Starr, D. L.; Bloom, J. S.; Brewer, J. M.; Butler, N. R.; Poznanski, D.; Rischard, M.; Klein, C.

    2009-09-01

    The Berkeley Transients Classification Pipeline (TCP) is a parallelized source identification, classification, and broadcast pipeline which ingests several real-time data torrents and emits science events of pre-articulated interest. The TCP's classification machine-learning algorithms are trained using a comprehensive science class hierarchy of light-curves which are resampled to emulate the cadence and quality of incoming observatory data streams. The referenced classified light-curves are contained within our growing public data warehouse, DotAstro.org (http://dotastro.org/). To effectively distinguish a source's classification from neighboring classes or hierarchical parents, dozens of real-number metrics (``features'') are derived from its light-curve, color information, spatial context, and historical data. Upon science class identification (or reclassification), a VOEvent XML containing all available information is broadcast to subscribed telescopes and science groups for followup. Subsequently acquired data for that source can then be fed back to DotAstro.org which the TCP will use to reinforce its internal model of the source's science class.

  20. 1-2 GeV synchrotron radiation facility at Lawrence Berkeley Laboratory

    SciTech Connect

    Berkner, K.H.

    1985-10-01

    The Advanced Light Source (ALS), a dedicated synchrotron radiation facility optimized to generate soft x-ray and vacuum ultraviole (XUV) light using magnetic insertion devices, was proposed by the Lawrence Berkeley Laboratory in 1982. It consists of a 1.3-GeV injection system, an electron storage ring optimized at 1.3 GeV (with the capability of 1.9-GeV operation), and a number of photon beamlines emanating from twelve 6-meter-long straight sections, as shown in Fig. 1. In addition, 24 bending-magnet ports will be avialable for development. The ALS was conceived as a research tool whose range and power would stimulate fundamentally new research in fields from biology to materials science (1-4). The conceptual design and associated cost estimate for the ALS have been completed and reviewed by the US Department of Energy (DOE), but preliminary design activities have not yet begun. The focus in this paper is on the history of the ALS as an example of how a technical construction project was conceived, designed, proposed, and validated within the framwork of a national laboratory funded largely by the DOE.

  1. Cyclotron maser and plasma wave growth in magnetic loops

    NASA Technical Reports Server (NTRS)

    Hamilton, Russell J.; Petrosian, Vahe

    1990-01-01

    Cyclotron maser and plasma wave growth which results from electrons accelerated in magnetic loops are studied. The evolution of the accelerated electron distribution is determined by solving the kinetic equation including Coulomb collisions and magnetic convergence. It is found that for modest values of the column depth of the loop the growth rates of instabilities are significantly reduced and that the reduction is much larger for the cyclotron modes than for the plasma wave modes. The large decrease in the growth rate with column depth suggests that solar coronal densities must be much lower than commonly accepted in order for the cyclotron maser to operate. The density depletion has to be similar to that which occurs during auroral kilometric radiation events in the magnetosphere. The resulting distributions are much more complicated than the idealized distributions used in many theoretical studies, but the fastest growing mode can still simply be determined by the ratio of electron plasma to gyrofrequency, U=omega(sub p)/Omega(sub e). However, the dominant modes are different than for the idealized situations with growth of the z-mode largest for U approximately less than 0.5, and second harmonic x-mode (s=2) or fundamental o-mode (s=1) the dominant modes for 0.5 approximately less than U approximately less than 1. The electron distributions typically contain more than one inverted feature which could give rise to wave growth. It is shown that this can result in simultaneous amplification of more than one mode with each mode driven by a different feature and can be observed, for example, by differences in the rise times of the right and left circularly polarized components of the associated spike bursts.

  2. Electromagnetic waves near the proton cyclotron frequency: Stereo observations

    SciTech Connect

    Jian, L. K.; Wei, H. Y.; Russell, C. T.; Luhmann, J. G.; Klecker, B.; Omidi, N.; Isenberg, P. A.; Goldstein, M. L.; Figueroa-Viñas, A.; Blanco-Cano, X.

    2014-05-10

    Transverse, near-circularly polarized, parallel-propagating electromagnetic waves around the proton cyclotron frequency were found sporadically in the solar wind throughout the inner heliosphere. They could play an important role in heating and accelerating the solar wind. These low-frequency waves (LFWs) are intermittent but often occur in prolonged bursts lasting over 10 minutes, named 'LFW storms'. Through a comprehensive survey of them from Solar Terrestrial Relations Observatory A using dynamic spectral wave analysis, we have identified 241 LFW storms in 2008, present 0.9% of the time. They are left-hand (LH) or right-hand (RH) polarized in the spacecraft frame with similar characteristics, probably due to Doppler shift of the same type of waves or waves of intrinsically different polarities. In rare cases, the opposite polarities are observed closely in time or even simultaneously. Having ruled out interplanetary coronal mass ejections, shocks, energetic particles, comets, planets, and interstellar ions as LFW sources, we discuss the remaining generation scenarios: LH ion cyclotron instability driven by greater perpendicular temperature than parallel temperature or by ring-beam distribution, and RH ion fire hose instability driven by inverse temperature anisotropy or by cool ion beams. The investigation of solar wind conditions is compromised by the bias of the one-dimensional Maxwellian fit used for plasma data calibration. However, the LFW storms are preferentially detected in rarefaction regions following fast winds and when the magnetic field is radial. This preference may be related to the ion cyclotron anisotropy instability in fast wind and the minimum in damping along the radial field.

  3. Hospital based superconducting cyclotron for neutron therapy: Medical physics perspective

    NASA Astrophysics Data System (ADS)

    Yudelev, M.; Burmeister, J.; Blosser, E.; Maughan, R. L.; Kota, C.

    2001-12-01

    The neutron therapy facility at the Gershenson Radiation Oncology Center, Harper University Hospital in Detroit has been operational since September 1991. The d(48.5)+Be beam is produced in a gantry mounted superconducting cyclotron designed and built at the National Superconducting Cyclotron Laboratory (NSCL). Measurements were performed in order to obtain the physical characteristics of the neutron beam and to collect the data necessary for treatment planning. This included profiles of the dose distribution in a water phantom, relative output factors and the design of various beam modifiers, i.e., wedges and tissue compensators. The beam was calibrated in accordance with international protocol for fast neutron dosimetry. Dosimetry and radiobiology intercomparions with three neutron therapy facilities were performed prior to clinical use. The radiation safety program was established in order to monitor and reduce the exposure levels of the personnel. The activation products were identified and the exposure in the treatment room was mapped. A comprehensive quality assurance (QA) program was developed to sustain safe and reliable operation of the unit at treatment standards comparable to those for conventional photon radiation. The program can be divided into three major parts: maintenance of the cyclotron and related hardware; QA of the neutron beam dosimetry and treatment delivery; safety and radiation protection. In addition the neutron beam is used in various non-clinical applications. Among these are the microdosimetric characterization of the beam, the effects of tissue heterogeneity on dose distribution, the development of boron neutron capture enhanced fast neutron therapy and variety of radiobiology experiments.

  4. Glow plasma trigger for electron cyclotron resonance ion sources.

    PubMed

    Vodopianov, A V; Golubev, S V; Izotov, I V; Nikolaev, A G; Oks, E M; Savkin, K P; Yushkov, G Yu

    2010-02-01

    Electron cyclotron resonance ion sources (ECRISs) are particularly useful for nuclear, atomic, and high energy physics, as unique high current generators of multicharged ion beams. Plasmas of gas discharges in an open magnetic trap heated by pulsed (100 micros and longer) high power (100 kW and higher) high-frequency (greater than 37.5 GHz) microwaves of gyrotrons is promising in the field of research in the development of electron cyclotron resonance sources for high charge state ion beams. Reaching high ion charge states requires a decrease in gas pressure in the magnetic trap, but this method leads to increases in time, in which the microwave discharge develops. The gas breakdown and microwave discharge duration becomes greater than or equal to the microwave pulse duration when the pressure is decreased. This makes reaching the critical plasma density initiate an electron cyclotron resonance (ECR) discharge during pulse of microwave gyrotron radiation with gas pressure lower than a certain threshold. In order to reduce losses of microwave power, it is necessary to shorten the time of development of the ECR discharge. For fast triggering of ECR discharge under low pressure in an ECRIS, we initially propose to fill the magnetic trap with the plasmas of auxiliary pulsed discharges in crossed ExB fields. The glow plasma trigger of ECR based on a Penning or magnetron discharge has made it possible not only to fill the trap with plasma with density of 10(12) cm(-3), required for a rapid increase in plasma density and finally for ECR discharge ignition, but also to initially heat the plasma electrons to T(e) approximately = 20 eV. PMID:20192326

  5. Glow plasma trigger for electron cyclotron resonance ion sources

    SciTech Connect

    Vodopianov, A. V.; Golubev, S. V.; Izotov, I. V.; Nikolaev, A. G.; Oks, E. M.; Savkin, K. P.; Yushkov, G. Yu.

    2010-02-15

    Electron cyclotron resonance ion sources (ECRISs) are particularly useful for nuclear, atomic, and high energy physics, as unique high current generators of multicharged ion beams. Plasmas of gas discharges in an open magnetic trap heated by pulsed (100 {mu}s and longer) high power (100 kW and higher) high-frequency (greater than 37.5 GHz) microwaves of gyrotrons is promising in the field of research in the development of electron cyclotron resonance sources for high charge state ion beams. Reaching high ion charge states requires a decrease in gas pressure in the magnetic trap, but this method leads to increases in time, in which the microwave discharge develops. The gas breakdown and microwave discharge duration becomes greater than or equal to the microwave pulse duration when the pressure is decreased. This makes reaching the critical plasma density initiate an electron cyclotron resonance (ECR) discharge during pulse of microwave gyrotron radiation with gas pressure lower than a certain threshold. In order to reduce losses of microwave power, it is necessary to shorten the time of development of the ECR discharge. For fast triggering of ECR discharge under low pressure in an ECRIS, we initially propose to fill the magnetic trap with the plasmas of auxiliary pulsed discharges in crossed ExB fields. The glow plasma trigger of ECR based on a Penning or magnetron discharge has made it possible not only to fill the trap with plasma with density of 10{sup 12} cm{sup -3}, required for a rapid increase in plasma density and finally for ECR discharge ignition, but also to initially heat the plasma electrons to T{sub e}{approx_equal}20 eV.

  6. Miniature cyclotron resonance ion source using small permanent magnet

    NASA Technical Reports Server (NTRS)

    Anicich, V. G.; Huntress, W. T., Jr. (Inventor)

    1980-01-01

    An ion source using the cyclotron resonance principle is described. A miniaturized ion source device is used in an air gap of a small permanent magnet with a substantially uniform field in the air gap of about 0.5 inch. The device and permanent magnet are placed in an enclosure which is maintained at a high vacuum (typically 10 to the minus 7th power) into which a sample gas can be introduced. The ion beam end of the device is placed very close to an aperture through which an ion beam can exit into the apparatus for an experiment.

  7. Cyclotron scattering lines in gamma-ray burst spectra

    NASA Technical Reports Server (NTRS)

    Harding, Alice K.; Preece, Robert D.

    1989-01-01

    If cyclotron scattering, rather than absorption, is responsible for the line features observed recently in two gamma-ray burst spectra (Murakami et al., 1988), then the second and higher harmonics are due to resonant scattering events that excite the electron to Landau levels above the ground state. Here, relativistic Compton scattering cross sections are used to estimate the expected ratio of third to second harmonics in the presence of Doppler broadening. At the field strength (1.7 TG) required to give first and second harmonics at 19 keV and 38 keV, there should be no detectable third harmonic in the spectrum.

  8. Superthermal electron distribution measurements from polarized electron cyclotron emission

    SciTech Connect

    Luce, T.C.; Efthimion, P.C.; Fisch, N.J.

    1988-06-01

    Measurements of the superthermal electron distribution can be made by observing the polarized electron cyclotron emission. The emission is viewed along a constant magnetic field surface. This simplifies the resonance condition and gives a direct correlation between emission frequency and kinetic energy of the emitting electron. A transformation technique is formulated which determines the anisotropy of the distribution and number density of superthermals at each energy measured. The steady-state distribution during lower hybrid current drive and examples of the superthermal dynamics as the runaway conditions is varied are presented for discharges in the PLT tokamak. 15 refs., 8 figs.

  9. Prospects and limitations of cyclotron resonance laser acceleration

    SciTech Connect

    Chen, C. )

    1992-07-01

    The cyclotron resonance laser (CRL) accelerator is a novel concept of accelerating continuous charged-particle beams to moderately or highly relativistic energies. This paper discusses prospects and limitations of this concept. In particular, a three-dimensional, self-consistent theory is used to analyze the nonlinear interaction of an electron beam with an intense traveling electromagnetic wave in such an accelerator. The parameter regimes of experimental interest are identified on the basis of scaling calculations. The results of simulation modeling of a multimegavolt electron CRL accelerator are presented. The possibility of building continuous-wave (cw) CRL accelerators is discussed.

  10. Frequency-scanning marginal oscillator for ion cyclotron resonance spectroscopy

    NASA Astrophysics Data System (ADS)

    Kemper, Paul R.; Bowers, Michael T.

    1982-07-01

    A number of ion cyclotron resonance applications have arisen in the past few years which require a frequency-scanned detection system. Since the traditional marginal oscillator detector has always been a fixed-frequency detector, alternative detection techniques such as bridge circuit detectors have become widely used. In this paper we present an alternative to the bridge detector, namely, a frequency-scanning marginal oscillator. Requirements and modifications necessary to convert a marginal oscillator to frequency scanning operation are discussed in detail and the necessary circuit diagrams presented. Finally, a theoretical comparison is made between bridge circuit and marginal oscillator sensitivities.

  11. Electron cyclotron resonance microwave ion sources for thin film processing

    SciTech Connect

    Berry, L.A.; Gorbatkin, S.M.

    1990-01-01

    Plasmas created by microwave absorption at the electron cyclotron resonance (ECR) are increasingly used for a variety of plasma processes, including both etching and deposition. ECR sources efficiently couple energy to electrons and use magnetic confinement to maximize the probability of an electron creating an ion or free radical in pressure regimes where the mean free path for ionization is comparable to the ECR source dimensions. The general operating principles of ECR sources are discussed with special emphasis on their use for thin film etching. Data on source performance during Cl base etching of Si using an ECR system are presented. 32 refs., 5 figs.

  12. Electron cyclotron current drive in DIII-D

    SciTech Connect

    Luce, T. C.; Lin-Liu, Y. R.; Harvey, R. W.; Giruzzi, G.; Lohr, J. M.; Petty, C. C.; Politzer, P. A.; Prater, R.; Rice, B. W.

    1999-09-20

    Clear measurements of the localized current density driven by electron cyclotron waves have been made on the DIII-D tokamak. Direct evidence of the current drive is seen on the internal magnetic field measurements by motional Stark effect spectroscopy. Comparison with theoretical calculations in the collisionless limit shows the experimental current drive exceeds the predictions by a substantial amount for currents driven near the half radius. In all cases the experimental current density profile is broader than the predicted one. (c) 1999 American Institute of Physics.

  13. RF physics of ICWC discharge at high cyclotron harmonics

    SciTech Connect

    Lyssoivan, A.; Van Eester, D.; Wauters, T.; Vervier, M.; Van Schoor, M.; Bobkov, V.; Rohde, V.; Schneider, P.; Douai, D.; Kogut, D.; Kreter, A.; Möller, S.; Philipps, V.; Sergienko, G.; Moiseenko, V.; Noterdaeme, J.-M.; Collaboration: TEXTOR Team; ASDEX Upgrade Team

    2014-02-12

    Recent experiments on Ion Cyclotron Wall Conditioning (ICWC) performed in tokamaks TEXTOR and ASDEX Upgrade with standard ICRF antennas operated at fixed frequencies but variable toroidal magnetic field demonstrated rather contrasting parameters of ICWC discharge in scenarios with on-axis fundamental ion cyclotron resonance (ICR) for protons,ω=ω{sub H+}, and with its high cyclotron harmonics (HCH), ω=10ω{sub cH+}⋅ HCH scenario: very high antenna coupling to low density RF plasmas (P{sub pl}≈0.9P{sub RF-G}) and low energy Maxwellian distribution of CX hydrogen atoms with temperature T{sub H}≈350 eV. Fundamental ICR: lower antenna-plasma coupling efficiency (by factor of about 1.5 times) and generation of high energy non-Maxwellian CX hydrogen atoms (with local energy E{sub ⊥H} ≥1.0 keV). In the present paper, we analyze the obtained experimental results numerically using (i) newly developed 0-D transport code describing the process of plasma production with electron and ion collisional ionization in helium-hydrogen gas mixture and (ii) earlier developed 1-D Dispersion Relation Solver accounting for finite temperature effects and collision absorption mechanisms for all plasma species in addition to conventionally examined Landau/TTPM damping for electrons and cyclotron absorption for ions. The numerical study of plasma production in helium with minor hydrogen content in low and high toroidal magnetic fields is presented. The investigation of the excitation, conversion and absorption of plasma waves as function of B{sub T}-field suggests that only fast waves (FW) may give a crucial impact on antenna coupling and characteristics of the ICWC discharge using standard poloidally polarized ICRF antennas designed to couple RF power mainly to FW. The collisional (non-resonant) absorption by electrons and ions and IC absorption by resonant ions of minor concentration in low T{sub e} plasmas is studied at fundamental ICR and its high harmonics.

  14. Development of a high current H(-) ion source for cyclotrons.

    PubMed

    Etoh, H; Aoki, Y; Mitsubori, H; Arakawa, Y; Mitsumoto, T; Yajima, S; Sakuraba, J; Kato, T; Okumura, Y

    2014-02-01

    A multi-cusp DC H(-) ion source has been designed and fabricated for medical applications of cyclotrons. Optimization of the ion source is in progress, such as the improvement of the filament configuration, magnetic filter strength, extraction electrode's shape, configuration of electron suppression magnets, and plasma electrode material. A small quantity of Cs has been introduced into the ion source to enhance the negative ion beam current. The ion source produced 16 mA of DC H(-) ion beam with the Cs-seeded operation at a low arc discharge power of 2.8 kW. PMID:24593547

  15. Experimental demonstration of high efficiency electron cyclotron autoresonance acceleration

    SciTech Connect

    LaPointe, M.A.; Yoder, R.B.; Wang, C.; Ganguly, A.K.; Hirshfield, J.L.

    1996-04-01

    First experimental results are reported on the operation of a multimegawatt 2.856 GHz cyclotron autoresonance accelerator (CARA). A 90{endash}100 kV, 2{endash}3 MW linear electron beam has had up to6.6 MW added to it in CARA, with an rf-to-beam power efficiency of up to 96{percent}. This efficiency level is larger than that reported for any fast-wave interaction between radiation and electrons, and also larger than that in normal conducting rf linear accelerators. The results obtained are in good agreement with theoretical predictions. {copyright} {ital 1996 The American Physical Society.}

  16. Calibration of electron cyclotron emission radiometer for KSTAR.

    PubMed

    Kogi, Y; Jeong, S H; Lee, K D; Akaki, K; Mase, A; Kuwahara, D; Yoshinaga, T; Nagayama, Y; Kwon, M; Kawahata, K

    2010-10-01

    We developed and installed an electron cyclotron emission radiometer for taking measurements of Korea Superconducting Tokamak Advanced Research (KSTAR) plasma. In order to precisely measure the absolute value of electron temperatures, a calibration measurement of the whole radiometer system was performed, which confirmed that the radiometer has an acceptably linear output signal for changes in input temperature. It was also found that the output power level predicted by a theoretical calculation agrees with that obtained by the calibration measurement. We also showed that the system displays acceptable noise-temperature performance around 0.23 eV. PMID:21033948

  17. Beam injection improvement for electron cyclotron resonance charge breeders

    SciTech Connect

    Lamy, T.; Angot, J.; Sortais, P.; Thuillier, T.

    2012-02-15

    The injection of a 1+ beam into an electron cyclotron resonance (ECR) charge breeder is classically performed through a grounded tube placed on its axis at the injection side. This tube presents various disadvantages for the operation of an ECR charge breeder. First experiments without a grounded tube show a better use of the microwave power and a better charge breeding efficiency. The optical acceptance of the charge breeder without decelerating tube allows the injection of high intensity 1+ ion beams at high energy, allowing metals sputtering inside the ion source. The use of this method for refractory metallic ion beams production is evaluated.

  18. Cyclotron line resonant transfer through neutron star atmospheres

    NASA Technical Reports Server (NTRS)

    Wang, John C. L.; Wasserman, Ira M.; Salpeter, Edwin E.

    1988-01-01

    Monte Carlo methods are used to study in detail the resonant radiative transfer of cyclotron line photons with recoil through a purely scattering neutron star atmosphere for both the polarized and unpolarized cases. For each case, the number of scatters, the path length traveled, the escape frequency shift, the escape direction cosine, the emergent frequency spectra, and the angular distribution of escaping photons are investigated. In the polarized case, transfer is calculated using both the cold plasma e- and o-modes and the magnetic vacuum perpendicular and parallel modes.

  19. Linear coupling of acoustic and cyclotron waves in plasma flows

    SciTech Connect

    Rogava, Andria; Gogoberidze, Grigol

    2005-05-15

    It is found that in magnetized electrostatic plasma flows the velocity shear couples ion-acoustic waves with ion-cyclotron waves and leads, under favorable conditions, to their efficient reciprocal transformations. It is shown that in a two-dimensional setup this coupling has a remarkable feature: it is governed by equations that are mathematically equal to the ones describing coupling of sound waves with internal gravity waves [Rogava and Mahajan, Phys. Rev. E 55, 1185 (1997)] in neutral fluids. For flows with low shearing rates a fully analytic, quantitative description of the coupling efficiency, based on a noteworthy quantum-mechanical analogy, is given and transformation coefficients are calculated.

  20. Potential applications of an electron cyclotron resonance multicusp plasma source

    SciTech Connect

    Tsai, C.C.; Berry, L.A.; Gorbatkin, S.M.; Haselton, H.H.; Roberto, J.B.; Stirling, W.L.

    1989-01-01

    An electron cyclotron resonance (ECR) multicusp plasmatron has been developed by feeding a multicusp bucket arc chamber with a compact ECR plasma source. This novel source produced large (about 25-cm-diam), uniform (to within {plus minus}10%), dense (>10{sup 11}-cm{sup -3}) plasmas of argon, helium, hydrogen, and oxygen. It has been operated to produce an oxygen plasma for etching 12.7-cm (5-in.) positive photoresist-coated silicon wafers with uniformity within {plus minus}8%. Results and potential applications of this new ECR plasma source for plasma processing of thin films are discussed. 21 refs., 10 figs.

  1. A cyclotron-maser instability associated with a nongyrotropic distribution

    NASA Technical Reports Server (NTRS)

    Freund, H. P.; Dong, J. Q.; Wu, C. S.; Lee, L. C.

    1987-01-01

    A stability analysis for the cyclotron-maser instability in the presence of a nongyrotropic electron distribution is presented. The model configuration describes a uniformly magnetized cold ambient plasma that contains a relatively diffuse suprathermal electron component coherently bunched in gyrophase. The stability of perturbations propagating parallel to the ambient magnetic field is considered, and substantial growth rates are found to occur. The results are contrasted with those found for a comparable gyrotropic loss-cone distribution, and it is found that the nongyrotropic instability is characterized by substantially higher growth rates.

  2. Cyclotron production of Ac-225 for targeted alpha therapy.

    PubMed

    Apostolidis, C; Molinet, R; McGinley, J; Abbas, K; Möllenbeck, J; Morgenstern, A

    2005-03-01

    The feasibility of producing Ac-225 by proton irradiation of Ra-226 in a cyclotron through the reaction Ra-226(p,2n)Ac-225 has been experimentally demonstrated for the first time. Proton energies were varied from 8.8 to 24.8 MeV and cross-sections were determined by radiochemical analysis of reaction yields. Maximum yields were reached at incident proton energies of 16.8 MeV. Radiochemical separation of Ac-225 from the irradiated target yielded a product suitable for targeted alpha therapy of cancer. PMID:15607913

  3. Plane gyroklinotron at first and third harmonics of cyclotron frequency

    SciTech Connect

    Kurayev, A.A.; Lukashonok, D.V.; Sinitsyn, A.K. E-mail: timka86@gmail.com

    2011-07-01

    The results of gyroklinotron's parameters optimization for efficiency at f = 100 GHz with interaction on first and third harmonics of the cyclotron frequency are presented. The predicted electron gyroklinotron's efficiency reaches 70% on first harmonic and 40% on third harmonic. This is more than in usual gyrotron. Besides in contrast to usual gyrotron the width electron beam on radius of guiding centers of electron orbits in gyroklinotron may considerable exceed working wave length {lambda}. This allows to use in it considerable more power of electron beams EB then in usual gyrotron. (author)

  4. Deposition of diamondlike films by electron cyclotron resonance microwave plasmas

    NASA Technical Reports Server (NTRS)

    Pool, F. S.; Shing, Y. H.

    1990-01-01

    Hard a-C:H films have been deposited through electron cyclotron resonance (ECR) microwave plasma decomposition of CH4 diluted with H2 gas. It has been found that hard diamondlike films could only be produced under a RF-induced negative self-bias of the substrate stage. Raman spectra indicate the deposition of two distinct film types: one film type exhibiting well-defined bands at 1360 and 1580/cm and another displaying a broad Raman peak centered at approximately 1500/cm. Variation of the mirror magnetic-field profile of the ECR system was examined, demonstrating the manipulation of film morphology through the extraction of different ion energies.

  5. A compact accelerating structure for stacked isochronous cyclotrons

    NASA Astrophysics Data System (ADS)

    Meitzler, C. R.; Byeon, J.; McIntyre, P. M.; Rogers, Bob; Sattarov, A.

    2003-03-01

    An accelerator-driven thorium cycle power reactor is being developed, based on a flux-coupled stack of isochronous cyclotrons. (IC) The stack consists of seven independent accelerators (total beam power 15 MW at 1 GeV), stacked on a spacing ˜ 20 cm. The close spacing poses unique problems for the design of the accelerating cavities. We have invented a 4-bar RF dipole structure for the purpose. We have built a cold model and are studying its operating characteristics. The structure will be described. We present measurements of the resonant frequency, parasitic capacitances, and electric and magnetic field distributions in the structure.

  6. Linear coupling of acoustic and cyclotron waves in plasma flows

    NASA Astrophysics Data System (ADS)

    Rogava, Andria; Gogoberidze, Grigol

    2005-05-01

    It is found that in magnetized electrostatic plasma flows the velocity shear couples ion-acoustic waves with ion-cyclotron waves and leads, under favorable conditions, to their efficient reciprocal transformations. It is shown that in a two-dimensional setup this coupling has a remarkable feature: it is governed by equations that are mathematically equal to the ones describing coupling of sound waves with internal gravity waves [Rogava and Mahajan, Phys. Rev. E 55, 1185 (1997)] in neutral fluids. For flows with low shearing rates a fully analytic, quantitative description of the coupling efficiency, based on a noteworthy quantum-mechanical analogy, is given and transformation coefficients are calculated.

  7. 76 FR 80982 - International Cyclotron, Inc., Hato Rey, Puerto Rico; Order Suspending Licensed Activities

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-27

    ... radioactive material above specified amounts must provide a guarantee or other financial arrangement that... authorization to possess and use radioactive material of half-life greater than 120 days and in quantities... International Cyclotron, Inc. (International Cyclotron; Licensee) is the holder of Byproduct Materials...

  8. Method and apparatus for preventing cyclotron breakdown in partially evacuated waveguide

    SciTech Connect

    Moeller, C P

    1987-08-18

    It is an object of this invention to provide a method and apparatus for preventing cyclotron breakdown in a partially evacuated waveguide used to insert microwave energy for electron cyclotron heating in a plasma magnetic confinement device. An electrostatic field is applied along a section of such a waveguide in order to run seed electrons into the wall of the waveguide.

  9. Quantum non demolition measurement of cyclotron excitations in a Penning trap

    NASA Technical Reports Server (NTRS)

    Marzoli, Irene; Tombesi, Paolo

    1993-01-01

    The quantum non-demolition measurement of the cyclotron excitations of an electron confined in a Penning trap could be obtained by measuring the resonance frequency of the axial motion, which is coupled to the cyclotron motion through the relativistic shift of the electron mass.

  10. Sawtooth-Control Mechanism using Toroidally Propagating Ion-Cyclotron-Resonance Waves in Tokamaks

    SciTech Connect

    Graves, J. P.; Coda, S.; Chapman, I.

    2009-02-13

    The sawtooth control mechanism in plasmas employing off-axis toroidally propagating ion cyclotron resonance waves in tokamaks is reinvestigated. The radial drift excursion of energetic passing ions distributed asymmetrically in the velocity parallel to the magnetic field determines stability when the rational q=1 surface resides within a narrow region centered about the shifted fundamental cyclotron resonance.

  11. Ion-cyclotron turbulence and diagonal double layers in a magnetospheric plasma

    NASA Technical Reports Server (NTRS)

    Liperovskiy, V. A.; Pudovkin, M. I.; Skuridin, G. A.; Shalimov, S. L.

    1981-01-01

    A survey of current concepts regarding electrostatic ion-cyclotron turbulence (theory and experiment), and regarding inclined double potential layers in the magnetospheric plasma is presented. Anomalous resistance governed by electrostatic ion-cyclotron turbulence, and one-dimensional and two-dimensional models of double electrostatic layers in the magnetospheric plasma are examined.

  12. The Upgrade Project at Texas A and M University Cyclotron Institute: Update

    SciTech Connect

    Tabacaru, G.; Abegglen, F.; Chubaryan, G.; Derrig, G.; Clark, H. L.; Kim, G.; May, D.; Tribble, R. E.; Aerje, J.

    2010-11-24

    The Cyclotron Institute at Texas A and M University is currently under an upgrade process. The plan is to produce re-accelerated radioactive ion beams using the recommissioned 88'' Cyclotron as a driver and two different devices. The technique for producing radioactive species will be presented.

  13. Reducing Our Carbon Footprint: A Low-Energy House in Berkeley, Kabul, and Washington DC (LBNL Science at the Theater)

    SciTech Connect

    Diamond, Rick

    2007-09-17

    How well can we assess and improve building energy performance in California homes? How much energy-and carbon-do homes use in other parts of the world? Rick Diamond, deputy group leader of the Berkeley Lab Energy Performance of Buildings Group, discusses change, global solutions, and the stories of three houses in Berkeley, Kabul (Afghanistan), and Washington, D.C. Diamond, who is also a senior advisor at the California Institute for Energy and Environment, investigates user interactions with the built environment for improved building energy performance. The group has studied a wide range of issues related to energy use in housing, including duct system efficiency, user behavior, and infiltration and ventilation measurements.

  14. Reducing Our Carbon Footprint: A Low-Energy House in Berkeley, Kabul, and Washington DC (LBNL Science at the Theater)

    ScienceCinema

    Diamond, Rick

    2011-04-28

    How well can we assess and improve building energy performance in California homes? How much energy-and carbon-do homes use in other parts of the world? Rick Diamond, deputy group leader of the Berkeley Lab Energy Performance of Buildings Group, discusses change, global solutions, and the stories of three houses in Berkeley, Kabul (Afghanistan), and Washington, D.C. Diamond, who is also a senior advisor at the California Institute for Energy and Environment, investigates user interactions with the built environment for improved building energy performance. The group has studied a wide range of issues related to energy use in housing, including duct system efficiency, user behavior, and infiltration and ventilation measurements.

  15. Guidelines for generators to meet HWHF acceptance requirements for hazardous, radioactive, and mixed wastes at Berkeley Lab. Revision 3

    SciTech Connect

    Albert, R.

    1996-06-01

    This document provides performance standards that one, as a generator of hazardous chemical, radioactive, or mixed wastes at the Berkeley Lab, must meet to manage their waste to protect Berkeley Lab staff and the environment, comply with waste regulations and ensure the continued safe operation of the workplace, have the waste transferred to the correct Waste Handling Facility, and enable the Environment, Health and Safety (EH and S) Division to properly pick up, manage, and ultimately send the waste off site for recycling, treatment, or disposal. If one uses and generates any of these wastes, one must establish a Satellite Accumulation Area and follow the guidelines in the appropriate section of this document. Topics include minimization of wastes, characterization of the wastes, containers, segregation, labeling, empty containers, and spill cleanup and reporting.

  16. Final Calibration of the Berkeley Extreme and Far-Ultraviolet Spectrometer on the ORFEUS-SPAS I and II Missions

    NASA Astrophysics Data System (ADS)

    Dixon, W. Van Dyke; Dupuis, Jean; Hurwitz, Mark

    2002-01-01

    The Berkeley Extreme and Far-Ultraviolet Spectrometer flew as part of the ORFEUS telescope on the ORFEUS-SPAS I and II space shuttle missions in 1993 and 1996, respectively. The data obtained by this instrument have now entered the public domain. To facilitate their use by the astronomical community, we have reextracted and recalibrated both data sets, converted them into a standard (FITS) format, and placed them in the Multimission Archive at STScI (MAST). Our final calibration yields improved wavelength scales and effective area curves for both data sets. Based on the development and utilization of the Orbiting and Retrievable Far and Extreme Ultraviolet Spectrometers (ORFEUS), a collaboration of the Institute for Astronomy and Astrophysics at the University of Tübingen, the Space Astrophysics Group of the University of California, Berkeley, and the Landessternwarte Heidelberg.

  17. Nonlinear theory of drift-cyclotron kinetics and the possible breakdown of gyro-kinetics

    SciTech Connect

    Waltz, R. E.; Deng Zhao

    2013-01-15

    A nonlinear theory of drift-cyclotron kinetics (termed cyclo-kinetics here) is formulated to test the breakdown of the gyro-kinetic approximations. Six dimensional cyclo-kinetics can be regarded as an extension of five dimensional gyro-kinetics to include high-frequency cyclotron waves, which can interrupt the low-frequency gyro-averaging in the (sixth velocity grid) gyro-phase angle. Nonlinear cyclo-kinetics has no limit on the amplitude of the perturbations. Formally, there is no gyro-averaging when all cyclotron (gyro-phase angle) harmonics of the perturbed distribution function (delta-f) are retained. Retaining only the (low frequency) zeroth cyclotron harmonic in cyclo-kinetics recovers both linear and nonlinear gyro-kinetics. Simple recipes are given for converting continuum nonlinear delta-f gyro-kinetic transport simulation codes to cyclo-kinetics codes by retaining (at least some) higher cyclotron harmonics.

  18. Emission of ion and electron cyclotron harmonic radiation from mode conversion layers

    SciTech Connect

    Swanson, D.G.; Cho, S. )

    1989-07-01

    The asymmetry of cyclotron radiation from a mode conversion layer is presented for harmonics of the ion cyclotron frequency and the second harmonic of the electron cyclotron frequency for weakly relativistic electrons. The same form of Kirchhoff's law is found for all cases, relating the emission along each branch to the absorption of an incident wave along the corresponding branch. Results show that the fast wave radiation is more strongly asymmetric at the third harmonic than at the second harmonic of the ion cyclotron frequency, while the slow wave radiation ratio is about same. At the second cyclotron harmonic of weakly relativistic electrons, the asymmetry of radiation is found to be small at high temperature. The effect of equilibrium Bernstein wave radiation is also discussed.

  19. Emission of ion and electron cyclotron harmonic radiation from mode conversion layers

    SciTech Connect

    Cho, S.; Swanson, D.G. )

    1990-02-01

    The asymmetry of cyclotron radiation from a mode conversion layer is presented for harmonics of the ion cyclotron frequency and the second harmonic of the electron cyclotron frequency for weakly relativistic electrons. The same form of Kirchhoff's law is found for all cases, relating the emission along each branch to the absorption of an incident wave along the corresponding branch. Results show that the fast wave radiation is more strongly asymmetric at the third harmonic than at the second harmonic of the ion cyclotron frequency, while the slow wave radiation ratio is about same. At the second cyclotron harmonic of weakly relativistic electrons, the asymmetry of radiation is found to be small at high temperature. The effect of equilibrium Bernstein wave radiation is also discussed.

  20. Evolution of the axial electron cyclotron maser instability, with applications to solar microwave spikes

    NASA Technical Reports Server (NTRS)

    Vlahos, Loukas; Sprangle, Phillip

    1987-01-01

    The nonlinear evolution of cyclotron radiation from streaming and gyrating electrons in an external magnetic field is analyzed. The nonlinear dynamics of both the fields and the particles are treated fully relativistically and self-consistently. The model includes a background plasma and electrostatic effects. The analytical and numerical results show that a substantial portion of the beam particle energy can be converted to electromagnetic wave energy at frequencies far above the electron cyclotron frequency. In general, the excited radiation can propagate parallel to the magnetic field and, hence, escape gyrothermal absorption at higher cyclotron harmonics. The high-frequency Doppler-shifted cyclotron instability can have saturation efficiencies far higher than those associated with well-known instabilities of the electron cyclotron maser type. Although the analysis is general, the possibility of using this model to explain the intense radio emission observed from the sun is explored in detail.